WorldWideScience
1

Electrostatic probe vacuum system for TCA BR tokamak  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the technical design and performance of the diagnostic system installed in the tokamak TCABR to measure parameters of the plasma edge. The system consists of four Langmuir probes under remote control. (author)

1999-12-01

2

Edge biasing in the WEGA stellarator  

Energy Technology Data Exchange (ETDEWEB)

The WEGA stellarator is used to confine low temperature, overdense (densities exceeding the cut-off density of the heating wave) plasmas by magnetic fields in the range of B=50-500 mT. Microwave heating systems are used to ignite gas discharges using hydrogen, helium, neon or argon as working gases. The produced plasmas have been analyzed using Langmuir and emissive probes, a single-channel interferometer and ultra-high resolution Doppler spectroscopy. For a typical argon discharge in the low field operation, B=56 mT, the maximum electron density is n{sub e}{proportional_to}10{sup 18} m{sup -3} with temperatures in the range of T=4-12 eV. The plasma parameters are determined by using Langmuir probes and are cross-checked with interferometry. It is demonstrated within this work that the joint use of emissive probes and ultra-high resolution Doppler spectroscopy allows a precise ...

2009-02-27

3

Plasma flow measurement using directional Langmuir probe under weakly ion-magnetized conditions  

Energy Technology Data Exchange (ETDEWEB)

It is both experimentally and theoretically demonstrated that ion flow velocity at an arbitrary angle with respect to the magnetic field can be measured with a directional Langmuir probe. Based on the symmetry argument, we show that the effect of magnetic field on directional probe current is exactly canceled in determining the ion flow velocity, and obtain the generalized relation between flow velocity and directional probe currents valid for any flowing direction. The absolute value of the flow velocity is determined by an in situ calibration method of the probe. The applicability limit of the present method to a strongly ion-magnetized plasma is experimentally examined. (author)

2000-07-01

4

The electron current to a Langmuir Probe in a flowing high-pressure plasma  

International Nuclear Information System (INIS)

This paper reports on the electron current to a Langmuir probe in a moving high-pressure plasma. The plasma is an atmospheric-pressure propane flame, and the probe's speed relative to the plasma is varied from 10 to 30 ms"-"1. The current is linearly dependent on the speed and appears to be comprised of two components - one driven by diffusion and the other by convection. A model is devised which can be used to measure the electron density. By comparing the density computed from this model to that measured from the ion current, it has been possible to measure the electron mobility in the flame gases. The value obtained here is in good agreement with theoretical calculations found in the literature.

5

Electron density and collision frequency of microwave resonant cavity produced discharges. [Progress report  

Energy Technology Data Exchange (ETDEWEB)

This progress report consists of an article, the abstract of which follows, and apparently the references and vita from a proposal. A review of perturbation diagnostics applied to microwave resonant cavity discharges is presented. The classical microwave perturbation technique examines the shift in the resonant frequency and cavity quality factor of the resonant cavity caused by low electron density discharges. However, modifications presented here allow the analysis to be applied to discharges with electron densities beyond the limit predicted by perturbation theory. An {open_quote}exact{close_quote} perturbation analysis is presented which models the discharge as a separate dielectric, thereby removing the restrictions on electron density imposed by the classical technique. The {open_quote}exact{close_quote} method also uses measurements of the shifts in the resonant conditions of the cavity. Thirdly, an electromagnetic analysis is presented which uses a ...

1992-12-31

6

Design of the electromagnetic fluctuations diagnostic for MFTF-B  

Energy Technology Data Exchange (ETDEWEB)

The Electromagnetic Fluctuations (EMF) diagnostic will be used to monitor ion fluctuations which could be unstable in MFTF-B. Each probe assembly includes a high impedance electrostatic probe to measure potential fluctuations, and a group of nested, single turn loops to measure magnetic fluctuations in three directions. Eventually, more probes and loops will be added to each probe assembly for making more detailed measurements. The sensors must lie physically close to the plasma edge and are radially positionable. Also, probes at separate axial locations can be positioned to connect along the same magnetic field line. These probes are similar in concept to the rf probes used on TMX, but the high thermal load for 30-second shots on MFTF-B requires a water-cooled design along with temperature monitors. Each signal channel ...

1983-11-28

7

Sheath characteristic in ECR plasma nitriding  

International Nuclear Information System (INIS)

The sheath plasma characteristics changing with the negative bias applied to the substrate during electron cyclotron resonance plasma nitriding are studied. The sheath characteristics obtained by a Langmuir single probe and an ion energy analyzer show that when the negative bias applied to the substrate is increasing, the most probable energy of ions in the sheath and the full width of half maximum of ions energy distribution increase, the thickness of the sheath also increases, whereas the saturation current of ion decreases. It has been found from the optical emission spectrum that there are strong lines of N_2 and N_2"+. Based on the experiment results the mechanism of plasma nitriding is discussed

2001-04-01

8

S-shaped magnetic macroparticle filter for cathodic arc deposition  

Energy Technology Data Exchange (ETDEWEB)

A new magnetic macroparticle filter design consisting of two 90{sup o} filters forming an S-shape is described. Transport properties of this S-filter are investigated using Langmuir and deposition probes. It is shown that filter efficiency is product of the efficiencies of two 90{sup o} filters and the deposition rate is still acceptably high to perform thin film deposition. Films of amorphous hard carbon have been deposited using a 90{sup o} filter and the S-filter, and macroparticle content of the films are compared.

1996-04-01

9

Plasma density measurement of electron cyclotron resonance ion source for neutron generator  

International Nuclear Information System (INIS)

It is a traditional method to diagnose electron-cyclotron-resonance (ECR) plasma source, using a single probe to measure the current-voltage curve of the plasma, based on which and theoretic formula the plasma density can be computed. The article adopts a Langmuir probe having a role of emission electrons to measure two different current-voltage curves with and without emission. It is ease to get the plasma potential via the inflexion of the two curves and compute directly various physical quantities by the assistant computer, such as electron temperature, electron/ion density, plasma potential etc. The deviation is about percent 1.8 between the measurement results by traditional and the new method, but the latter has higher efficiency. (authors)

2007-12-01

10

Thermal electron attachment and detachment, and electron affinities  

International Nuclear Information System (INIS)

Knighton et al. used a pulsed high pressure mass spectrometer to examine thermal electron detachment from C_6F_6"-. This technique had been used earlier for the measurement or detachment rate coefficients for azulene anions as a function of temperature. C_6F_6"- and c-C_4F_6"- have been studied by Datskos et al. using a pulsed drift tube. In our laboratory, we have used a flowing afterglow Langmuir probe (FALP) apparatus to measure the thermal electron detachment rate coefficient for c-C_4F_8"- ions at 375 K. We have also measured the electron attachment rate coefficient for c-C_4F_8 at 303 K and 375 K. (author).

1994-03-20

11

Estimation of plasma density by surface plasmons for surface-wave plasmas  

International Nuclear Information System (INIS)

An estimation method of plasma density based on surface plasmons theory for surface-wave plasmas is proposed. The number of standing-wave is obtained directly from the discharge image, and the propagation constant is calculated with the trim size of the apparatus in this methods, then plasma density can be determined with the value of 9.1 x 1017 m-3. Plasma density is measured using a Langmuir probe, the value is 8.1 x 1017 m-3 which is very close to the predicted value of surface plasmons theory. Numerical simulation is used to check the number of standing-wave by the finite-difference time-domain (FDTD) method also. All results are compatible both of theoretical analysis and experimental measurement. (authors)

2008-12-01

12

Eddy currents signal processing for steam generator inspection in PWR nuclear power plants  

International Nuclear Information System (INIS)

Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostic system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of ...

1992-01-01

13

Plasma-edge studies in ISX-B and EBT-S using surface probes and laser-induced fluorescence  

Energy Technology Data Exchange (ETDEWEB)

Surface probe and laser-induced fluorescence measurements in ISX-B and EBT-S have made significant contributions to the understanding of plasma edge characteristics and plasma-surface interactions in these devices. Where comparison is possible, these techniques have led to results which are consistent with plasma diagnostics. Charge-exchange neutral sputtering and self-ion sputtering have been identified as the dominent heavy impurity release mechanisms in ISX-B and EBT-S, respectively.

1982-08-01

14

Ion Langmuir waves in a nonneutral plasma  

Energy Technology Data Exchange (ETDEWEB)

A nonneutral /sup 7/Li/sup +/ ion plasma is described in which ion Langmuir waves are observed for the first time. The properties of these waves near the Brillouin density limit are investigated.

1981-01-05

15

A pump-probe XFEL particle injector for hydrated samples  

CERN Document Server

We have developed a liquid jet injector system that can be used for hydrated sample delivery at X-ray Free Electron Laser (XFEL) sources and 3rd generation synchrotron sources. The injector is based on the Gas Dynamic Virtual Nozzle (GDVN), which generates a liquid jet with diameter ranging from 300 nm to 20 {\\mu}m without the clogging problems associated with conventional Rayleigh jets. An improved nozzle design is presented here. A differential pumping system protects the vacuum chamber and an in-vacuum microscope allows observation of the liquid jet for diagnostics while it is being exposed to the X-ray beam. A fiber optically coupled pump laser illuminating the jet is incorporated for pump-probe experiments. First results with this injector system have been obtained at the LCLS.

2011-01-01

16

Surface modification of titanium by radio frequency plasma nitriding  

Energy Technology Data Exchange (ETDEWEB)

Radio frequency (RF) plasma nitriding using different input plasma processing powers (250-600 W) improves the surface of titanium by forming hard phases of TiN, Ti{sub 2}N, and Ti (N) into the surface. The characteristics of the compound layer have been investigated by optical microscopy, microhardness measurements, and X-ray diffraction. The effect of plasma power on the sample temperature, electron temperature, and plasma density was studied using Langmuir double probe. The measured surface hardness value of the compound layer is 2190 HV 0.1 for treated sample at plasma power 500 W. The compound thickness continuously increases as the plasma power increases. The highest nitriding rate of 5.88 {mu}m{sup 2}/s was recorded when the input plasma power was adjusted at 550 W. This high nitriding rate of treated titanium samples is ascribed to the high concentration of active nitrogen species in the plasma atmosphere and the formed microcracks near ...

2006-02-21

17

Surface modification of titanium by radio frequency plasma nitriding  

International Nuclear Information System (INIS)

Radio frequency (RF) plasma nitriding using different input plasma processing powers (250-600 W) improves the surface of titanium by forming hard phases of TiN, Ti_2N, and Ti (N) into the surface. The characteristics of the compound layer have been investigated by optical microscopy, microhardness measurements, and X-ray diffraction. The effect of plasma power on the sample temperature, electron temperature, and plasma density was studied using Langmuir double probe. The measured surface hardness value of the compound layer is 2190 HV 0.1 for treated sample at plasma power 500 W. The compound thickness continuously increases as the plasma power increases. The highest nitriding rate of 5.88 #mu#m"2/s was recorded when the input plasma power was adjusted at 550 W. This high nitriding rate of treated titanium samples is ascribed to the high concentration of active nitrogen species in the plasma atmosphere and the formed microcracks near to the ...

2006-02-21

18

Surface hardening utilizing high-density plasma nitriding on stainless steel alloys  

Energy Technology Data Exchange (ETDEWEB)

By using a plasma nitriding procedure at the PUPR Mirror Cusp Plasma machine, surface hardness is increased in 302/304-type stainless steel samples by exposing them to high-ion-density plasma at high vacuum. This method successfully dopes the surface of the material with strengthening nitrogen ions, without the use of chemical procedures that sacrifice the resistance to corrosion of the given material. A 500 V negative bias is placed on the sample exposed to the nitrogen plasma, where high-energy ions are therefore attracted and immersed into the metallic matrix microns into the surface of the stainless steel. This potential maintains a constant surface temperature at approximately 800 deg. C. The plasma parameters including ion density and plasma temperature were diagnosed using single Langmuir probes. The stainless steel samples were then tested using scanning electron microscopy (SEM), and Vickers micro-hardness testing to determine the ...

2008-10-15

19

Surface hardening utilizing high-density plasma nitriding on stainless steel alloys  

International Nuclear Information System (INIS)

By using a plasma nitriding procedure at the PUPR Mirror Cusp Plasma machine, surface hardness is increased in 302/304-type stainless steel samples by exposing them to high-ion-density plasma at high vacuum. This method successfully dopes the surface of the material with strengthening nitrogen ions, without the use of chemical procedures that sacrifice the resistance to corrosion of the given material. A 500 V negative bias is placed on the sample exposed to the nitrogen plasma, where high-energy ions are therefore attracted and immersed into the metallic matrix microns into the surface of the stainless steel. This potential maintains a constant surface temperature at approximately 800 deg. C. The plasma parameters including ion density and plasma temperature were diagnosed using single Langmuir probes. The stainless steel samples were then tested using scanning electron microscopy (SEM), and Vickers micro-hardness testing to determine the ...

2008-10-01

20

Influence of the Alfven wave spectrum on the scrape-off layer of the TCA tokamak  

International Nuclear Information System (INIS)

The study of the scrape-off layer (SOL) during Alfven wave heating may lead to a better understanding of the antenna-plasma interaction. The scrape-off layer of the TCA tokamak has been widely investigated by means of Langmuir probes. The aim of this work is to present measurements on the influence of the Alfven wave spectrum on the scrape-off layer. These experiments have shown that the plasma boundary layer is strongly affected by the wave field, in particular the ion saturation current and the floating potential. In TCA, as the spectrum evolves due to a density rise, the passage of the Alfven continua and their associated eigenmodes, the Discrete Alfven Wave (DAW) induces a strong depletion in the edge density of up to 70% during the continuum part and a density increase during the crossing of an eigenmode. The floating potential becomes negative during the continua and even more negative crossing the eigenmodes. In case of MHD mode ...

1988-05-01

21

Eddy currents signal processing for steam generator inspection in PWR nuclear power plants; Traitement des signaux de courants de Foucault pour le controle des tubes de generateurs de vapeur dans les centrales nucleaires REP  

Energy Technology Data Exchange (ETDEWEB)

Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostics system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of ...

1991-07-01

22

Eddy currents signal processing for steam generator inspection in PWR nuclear power plants. Traitement des signaux courants de Foucault pour le controle des tubes de generateurs de vapeur dans les centrales nucleaires REP  

Energy Technology Data Exchange (ETDEWEB)

Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostic system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of ...

1992-01-01

23

Locked nucleic acid (LNA): High affinity targeting of RNA for diagnostics and therapeutics  

DEFF Research Database (Denmark)

Locked nucleic acid (LNA) is a nucleic acid analogue containing one or more LNA nucleotide monomers with a bicyclic furanose unit locked in an RNA mimicking sugar conformation. This conformational restriction results in unprecedented hybridization affinity towards complementary single stranded RNA and thus, makes LNA uniquely suited for mimicking RNA structures and sequence specific targeting of RNA in vitro or in vivo. The focus of this paper is on LNAantisense, LNA-modified siRNA (siLNA), and detection and analysis of microRNAs by LNA-modified oligonucleotide probes.

2005-01-01

24

Gaseous dielectrics V  

Energy Technology Data Exchange (ETDEWEB)

This book discusses the progress and problems of current interest in gaseous dielectrics and their use, with special emphasis on insulation in high-voltage transmission lines and substations. Topics covered include: basic physics of gaseous dielectrics; basic mechanisms; gas decomposition, reactions and toxicity; diagnostics and field probes; gases and mixtures for GIS transformers and circuit breakers; gaseous media for discharge chemistry and etching/corona; gas engineering for pulsed power and switching; gas breakdown under steep-fronted voltages; new developments in gas-insulated equipment and gas handling; gas/insulator interface/flashover; and quality control in testing gas-insulated equipment. Contains approximately 85 papers.

1987-01-01

25

Visualization and Analysis of Eddy Current Data from D-Probe  

Energy Technology Data Exchange (ETDEWEB)

Eddy current testing (ECT) method is widely used as the non-destructive evaluation (NDE) of the various kinds of material degradation occurring in nuclear power plants (NPPs) components including steam generator (SG) tubes. Detection of any defects or flaws in the steam generator tubes in the early stage is very important in maintenance of NPP for its primary role as the pressure boundary with thin wall thickness. Although the ECT technique provides lots of information for a SG management, it has a generic problem in its reliability due to a low ability in detect of small defects and some difficulty in a signal analysis. For the improvement of these shortcomings in conventional ECT, profile-MRPC (motorized rotating pancake coil) ECT technology was developed in KAERI. The key of this new technology is the development of new eddy current probes, designated as a diagnostic probe (D-probe). The ...

2009-05-15

26

Visualization and Analysis of Eddy Current Data from D-Probe  

International Nuclear Information System (INIS)

Eddy current testing (ECT) method is widely used as the non-destructive evaluation (NDE) of the various kinds of material degradation occurring in nuclear power plants (NPPs) components including steam generator (SG) tubes. Detection of any defects or flaws in the steam generator tubes in the early stage is very important in maintenance of NPP for its primary role as the pressure boundary with thin wall thickness. Although the ECT technique provides lots of information for a SG management, it has a generic problem in its reliability due to a low ability in detect of small defects and some difficulty in a signal analysis. For the improvement of these shortcomings in conventional ECT, profile-MRPC (motorized rotating pancake coil) ECT technology was developed in KAERI. The key of this new technology is the development of new eddy current probes, designated as a diagnostic probe (D-probe). The ...

2009-05-01

27

He-like ions as practical astrophysical plasma diagnostics: From stellar coronae to active galactic nuclei  

CERN Document Server

We review X-ray plasma diagnostics based on the line ratios of He-like ions. Triplet/singlet line intensities can be used to determine electronic temperature and density, and were first developed for the study of the solar corona. Since the launches of the X-ray satellites Chandra and XMM-Newton, these diagnostics have been extended and used (from CV to Si XIII) for a wide variety of astrophysical plasmas such as stellar coronae, supernova remnants, solar system objects, active galactic nuclei, and X-ray binaries. Moreover, the intensities of He-like ions can be used to determine the ionization process(es) at work, as well as the distance between the X-ray plasma and the UV emission source for example in hot stars. In the near future thanks to the next generation of X-ray satellites (e.g., Astro-H and IXO), higher-Z He-like lines (e.g., iron) will be resolved, allowing plasmas with higher temperatures and densities to be ...

2011-01-01

28

Formation of complex Langmuir and Langmuir-Blodgett films of water soluble rosebengal  

British Library Electronic Table of Contents (United Kingdom)

This communication reports the formation of complex Langmuir monolayer at the air-water interface by charge transfer types of interaction with the water soluble N-cetyl Formula Not Shown -trimethyl ammonium bromide (CTAB) molecules doped with rosebengal (RB), with the stearic acid (SA) molecules of a preformed SA Langmuir monolayer. The reaction kinetics of the formation of RB-CTAB-SA complex monolayer was monitored by observing the increase in surface pressure with time while the barrier was kept fixed. Completion of interaction kinetics was confirmed by FTIR study. This complex Langmuir films at the air-water interface was transferred onto solid substrates at a desired surface pressure to form multilayered Langmuir-Blodgett films. Spectroscopic characterizations reveal some molecular lev...

2007-01-01

29

Using Gamma-Ray Burst Prompt Emission to Probe Relativistic Shock Acceleration  

CERN Document Server

It is widely accepted that the prompt transient signal in the 10 keV - 10 GeV band from gamma-ray bursts (GRBs) arises from multiple shocks internal to the ultra-relativistic expansion. The detailed understanding of the dissipation and accompanying acceleration at these shocks is a currently topical subject. This paper explores the relationship between GRB prompt emission spectra and the electron (or ion) acceleration properties at the relativistic shocks that pertain to GRB models. The focus is on the array of possible high-energy power-law indices in accelerated populations, highlighting how spectra above 1 MeV can probe the field obliquity in GRB internal shocks, and the character of hydromagnetic turbulence in their environs. It is emphasized that diffusive shock acceleration theory generates no canonical spectrum at relativistic MHD discontinuities. This diversity is commensurate with the significant range of spectral indices discerned in prompt burst ...

2010-01-01

30

Fluorescence based molecular in vivo imaging; Fluoreszenzgestuetzte molekulare Bildgebung in vivo  

Energy Technology Data Exchange (ETDEWEB)

Molecular imaging represents a modern research area that allows the in vivo study of molecular biological process kinetics using appropriate probes and visualization methods. This methodology may be defined- apart from the contrast media injection - as non-abrasive. In order to reach an in vivo molecular process imaging as accurate as possible the effects of the used probes on the biological should not be too large. The contrast media as important part of the molecular imaging can significantly contribute to the understanding of molecular processes and to the development of tailored diagnostics and therapy. Since more than 15 years PTB is developing optic imaging systems that may be used for fluorescence based visualization of tissue phantoms, small animal models and the localization of tumors and their predecessors, and for the early recognition of inflammatory processes in clinical trials. Cellular changes occur during ...

2008-12-15

31

PROBE FOR FLOW PASSAGE INSPECTION  

J-STORE (Japan)

Full Text Available

2007-05-11

33

The Cause of an Eddy Current Signal Noise from a Steam Generator Tube and its Effect on the Detectability of a Crack  

International Nuclear Information System (INIS)

An eddy current inspection has been applied for a pre-service and in-service examination of a steam generator in nuclear power plants. The experience from the inspection of steam generators showed that many plants had an excessive number of tubes with eddy current noise signals over several hundreds, which originated from manufacturing anomalies. The plants in U.S suffered significant downstream inspection costs, history reviews, and diagnostic testing because some signals resembled flaws and others masked a flaw. These lessens learned resulted in issuing the guidelines for steam generator tubing specifications and repair, in order to reduce the number of anomalous signals in the tubes and also to provide the requirement of a signal to noise ratio by applying a field type examination with bobbin coil eddy current probes at a manufacturing process. Besides the noise signals of a bobbin coil eddy current probe from ...

2008-05-01

34

The combustion aerodynamics of a pulverized coal low NO{sub x} swirl burner in an industrial boiler  

Energy Technology Data Exchange (ETDEWEB)

This paper discusses the application of a Computational Fluid Dynamics (CFD) code (FLUENT) to predict temperature and velocity profiles, and particle trajectories in an industrial fired by a low NO{sub x} pulverized coal swirl burner. The predictions of the code were compared to experimental measurements of gas temperature, particle size distribution, and particle velocities. The diagnostics employed were a suction pyrometer and a Particle Counter Sizer Velocimeter Probe (PCSV-P). Good agreement was found between the temperature predictions and the measurements. In situ particle size distributions were predicted accurately using the Baum and Street model with a swelling factor of zero. The numerical modeling indicated that the Type II flow issued from the burner could be transformed into Type III flow, by eliminating swirl from the primary air stream, which provided the preferred particle trajectories and increased the combustion efficiency.

1996-12-31

35

Solute carrier transporters as targets for drug delivery and pharmacological intervention for chemotherapy  

British Library Electronic Table of Contents (United Kingdom)

Abstract Many solute carrier transporters that interact with anticancer agents and contribute to their pharmacokinetics have been shown to be differentially upregulated in cancer cells as a result of adaptive response to altered nutritional requirements. This review focuses on pathophysiological function of membrane transporters responsible for the influx of physiological substances including oligopeptides, amino acids, and organic cations and anions, and summarizes the recent knowledge regarding mechanisms in their gene expressions. Broad substrate specificity of enhanced oligopeptide H+/peptide cotransporter 1 activity in cancer cells is useful for tumor tissue-specific delivery of chemotherapeutic agents and positron emission tomography diagnostic probes. Amino acid transporters such as...

2011-01-01

36

Cancer-cell-specific cytotoxicity of non-oxidized iron elements in iron core-gold shell NPs  

British Library Electronic Table of Contents (United Kingdom)

Gold-coated iron nanoparticles (NPs) selectively and significantly (P <0.0001) inhibit proliferation of oral- and colorectal-cancer cells in vitro at doses as low as 5 mg/mL, but have little adverse effect on normal healthy control cells. The particle treatment caused delay in cell-cycle progression, especially in the S-phase. There was no significant difference in the NP uptake between cancer and control cells, and cytotoxicity resulted primarily from the iron core, before oxidation, rather than from the Fe ions released from the core. In contrast with magnetic NPs that usually serve as drug carriers, diagnostic probes or hyperthermia media, the iron, before oxidation, in the NPs selectively suppressed cancer cell growth and left healthy control cells unaffected in vitro and in vivo. This...

2011-01-01

37

Optical diagnostics based on elastic scattering: Recent clinical demonstrations with the Los Alamos Optical Biopsy System  

Energy Technology Data Exchange (ETDEWEB)

A non-invasive diagnostic tool that could identify malignancy in situ and in real time would have a major impact on the detection and treatment of cancer. We have developed and are testing early prototypes of an optical biopsy system (OBS) for detection of cancer and other tissue pathologies. The OBS invokes a unique approach to optical diagnosis of tissue pathologies based on the elastic scattering properties, over a wide range of wavelengths, of the microscopic structure of the tissue. The use of elastic scattering as the key to optical tissue diagnostics in the OBS is based on the fact that many tissue pathologies, including a majority of cancer forms, manifest significant architectural changes at the cellular and sub-cellular level. Since the cellular components that cause elastic scattering have dimensions typically on the order of visible to near-IR wavelengths, the elastic (Mie) scattering properties will be strongly wavelength ...

1993-08-01

38

INFLATABLE EDDY CURRENT INSPECTION PROBE FOR ...  

Science.gov (United States)

... INTERMEDIATE TO THE CENTRALIZERS IS A SENSING SECTION COMPRISED OF MULTIPLE EDDY CURRENT PROBES ON FLEXIBLE ...

1981-12-01

39

Chemical Reactor Diagnostics  

International Science & Technology Center (ISTC)

Development of Methods and Apparatus for Processes Diagnostics in Plasma Reactors at the Neutralization of Chemical Herbiside and Pestiside

40

Beam Diagnostic System for High Intensity Proton Linac at KAERI  

CERN Document Server

Beam Diagnostic System for High Intensity Proton Linac at KAERI

2003-01-01

41

Probe-Flaw Interactions with Eddy Current Array Probes  

Science.gov (United States)

... The development of various modeling methods for conventional eddy current probes (absolute, differential, two-port, etc.) has led to a general ...

43

SPECIAL EDDY CURRENT PROBES FOR HEAT ...  

Science.gov (United States)

... Accession Number : ADD326926. Title : SPECIAL EDDY CURRENT PROBES FOR HEAT EXCHANGER INSPECTION. Corporate Author : ...

1986-11-01

44

OPTIMIZATION OF EDDY CURRENT PROBES FOR NDT OF ...  

Science.gov (United States)

... Accession Number : ADD321199. Title : OPTIMIZATION OF EDDY CURRENT PROBES FOR NDT OF CARBON FIBER COMPOSITES. ...

1985-04-01

45

Multiple-Element Eddy Current Probes for Enhanced ...  

Science.gov (United States)

... Accession Number : ADD335251. Title : Multiple-Element Eddy Current Probes for Enhanced Inspection,. Corporate Author : ...

1993-07-01

46

Characterization of Absolute-Resonant Eddy Current Probes,  

Science.gov (United States)

... Accession Number : ADD335809. Title : Characterization of Absolute-Resonant Eddy Current Probes,. Corporate Author : ...

47

Advanced Nondestructive Evaluation (NDE) for Retirement for ...  

Science.gov (United States)

... 21 2.3 Eddy Current Probes ..... 22 2.3.1 Improved Probe Internal ...

2000-08-01

49

Modern Optical Diagnostics for Technical Combustion Research  

ScienceCinema

...different sparking language english ? ...

51

Diagnostic radiology: An Anglo-American textbook of imaging  

Energy Technology Data Exchange (ETDEWEB)

This multiauthored text is aimed particularly toward the resident or registrar training in diagnostic radiology. This is a text book on the entire scope of diagnostic imaging. It includes techniques and imaging modalities of all the systems, head, face and neck. The book covers the entire gamut of diagnostic radiology.

1986-01-01

52

One-step RNA pathogen detection with reverse transcriptase activity of a mutated thermostable Thermus aquaticus DNA polymerase.  

Science.gov (United States)

We describe the cloning and characterization of a mutated thermostable DNA polymerase from Thermus aquaticus (Taq) that exhibits an increased reverse transcriptase activity and is therefore designated for one-step PCR pathogen detection using established real-time detection methods. We demonstrate that this Taq polymerase mutant (Taq M1) has similar PCR sensitivity and nuclease activity as the respective Taq wild-type DNA polymerase. In addition, and in marked contrast to the wild-type, Taq M1 exhibits a significantly increased reverse transcriptase activity especially at high temperatures (>60 degrees C). RNA generally hosts highly stable secondary structure motifs, such as hairpins and G-quadruplexes, which complicate, or in the worst case obviate, reverse transcription (RT). Thus, RT at high temperatures is desired to weaken or melt secondary structure motifs. To demonstrate the ability of Taq M1 for RNA detection of pathogens, we performed TaqMan probe-based ...

2010-02-01

53

CP property of the Higgs at the #gamma##gamma# colliders using tt-bar production  

International Nuclear Information System (INIS)

We present results of an investigation to study CP violation in the Higgs sector in tt-bar production at a #gamma##gamma#-collider, via the process #gamma##gamma# #-># #phi# #-># tt-bar where the #phi# is a scalar with indeterminate CP parity. The study is performed in a model independent way parametrising the CP violating couplings in terms of six form factors #left brace#R(S_#gamma#), T(S_#gamma#), R(P_#gamma#), T(P_#gamma#), S_t, P_t#right brace#. The CP violation is reflected in the polarisation asymmetry of the produced top quark. We use the angular distribution of the decay lepton from t/t-bar as a diagnostic of this polarisation asymmetry and hence of the CP mixing, after showing that the asymmetries in the angular distribution are independent of any CP violation in the tbW vertex. We construct combined asymmetries in the initial state lepton (photon) polarization and the final state lepton charge and study how well different combinations of these form ...

2003-09-01

54

APSTNG: Neutron interrogation for detection of nuclear and CW weapons, explosives, and drugs  

Energy Technology Data Exchange (ETDEWEB)

A recently developed neutron diagnostic probe system has the potential to satisfy a significant number of van-mobile and fixed- portal requirements for nondestructive verification of sealed munitions and detection of contraband explosives and drugs. The probe is based on a unique associated-particle sealed-tube neutron generator (APSTNG) that interrogates the object of interest with a low-intensity beam of 14-MeV neutrons generated from the deuterium-tritium reaction and that detects the alpha-particle associated with each neutron. Gamma-ray spectra of resulting neutron inelastic scattering and fission reactions identify nuclides associated with all major chemicals in chemical warfare agents, explosives, and drugs, as well as many pollutants and fissile and fertile special nuclear material. Flight times determined from determined from detection times of the gamma-rays and alpha-particles yield a separate tomographic image ...

1992-07-01

55

High Resolution Eddy Current Probes for Non Destructive Testing  

Science.gov (United States)

New industrial Non Destructive Testing requires the development of new probes: technologies such as high spatial resolution probes for small breaking flaws detection or flexible probes for complex curved surfaces inspection. The CEA/LIST has designed and integrated 2 probes to answer industrial's constraints. The first one is based on Giant Magneto-Resistance and is able to detect 50 ?m3 flaws. The second one is based on micro-coils etched on kapton and its flexibility is adapted to curved surfaces inspection. Both are multi-elements probes, allowing fast inspection. This paper presents those new probes, their design and their performances.

2008-02-01

56

Metallic Langmuir and Langmuir-Blodgett films based on TTF derivatives and fatty acid  

Energy Technology Data Exchange (ETDEWEB)

Recent progress in the metallic conducting Langmuir-Blodgett (LB) films built from TTF derivative and fatty acids is reported. A simple LB method of transferring the mixed Langmuir (L) film of BEDO-TTF (BO) and stearic acid (SA) onto substrates provided metallic conducting LB films. A homogeneous L film formation on the water surface observed by Brewster angle microscope (BAM) is an essential factor for the well-ordered LB films. In the L film, the carboxylate group of fatty acid forms anion layer bringing about a spontaneous formation of mixed valence state (MVS) of BO layer. Similar spontaneous formation was also found in the molecular combination of nonoxygen-substituted donor of EDT-TTF and octadecanesulfonic acid (OS). This type of reaction would be useful for obtaining conducting LB films. For the LB films of BEDO-TTF and stearic acid, we found a negative transverse magnetoresistance at low temperature that was interpreted in the weak ...

2002-12-01

57

Determination of Inter-Phase Line Tension in Langmuir Films  

CERN Document Server

A Langmuir film is a molecularly thin film on the surface of a fluid; we study the evolution of a Langmuir film with two co-existing fluid phases driven by an inter-phase line tension and damped by the viscous drag of the underlying subfluid. Experimentally, we study an 8CB Langmuir film via digitally-imaged Brewster Angle Microscopy (BAM) in a four-roll mill setup which applies a transient strain and images the response. When a compact domain is stretched by the imposed strain, it first assumes a bola shape with two tear-drop shaped reservoirs connected by a thin tether which then slowly relaxes to a circular domain which minimizes the interfacial energy of the system. We process the digital images of the experiment to extract the domain shapes. We then use one of these shapes as an initial condition for the numerical solution of a boundary-integral model of the underlying hydrodynamics and compare the subsequent images of ...

2007-01-01

58

Mechanism of iron inhibition by stearic acid Langmuir-Blodgett monolayers  

Energy Technology Data Exchange (ETDEWEB)

Many organic compounds can be adsorbed onto the interface of a metal and solution to form a thin film that inhibits the corrosion process according to a blocking and/or negative catalytic effect. Using the Langmuir-Blodgett (LB) technique, stearic acid (SA) monolayers were deposited onto the surface of an iron (Fe) electrode to study the inhibition effect and the mechanism of SA in a neutral medium. Molecular orientation and the number of deposited monolayers of SA were shown to have marked effects on inhibition of Fe corrosion. The inhibition mechanism depended mainly on blocking.

1995-01-01

59

Array coil probe: Final report  

Energy Technology Data Exchange (ETDEWEB)

Nuclear steam generator tubes have become flawed in ways that challenge conventional eddy current probes. In response to the shortcomings of conventional probes, array probes have been developed to improve measurement capabilities. However, the commercially available array probes have exhibited several weaknesses that offset the advantages and limit the applications in steam generator inspections. A primary weakness is the relatively high rate of probe failure coupled with the high unit cost for each probe. This can be costly for a utility in the time lost for probe replacement and increased radiation exposure in addition to the probe costs. Other weaknesses which make array probes undesirable for routine use are: poor mechanical and electrical characteristics; difficulty in operation and ...

1987-03-01

60

Neutron detection techniques for plasma diagnostics at the Joint European Torus (JET)  

International Nuclear Information System (INIS)

The importance of neutron measurements both as a succinct measure of the progress to fusion ignition using the magnetic confinement route and also as a diagnostic of plasma conditions is discussed. The various neutron diagnostic systems that have been or are being constructed by AERE Harwell for JET are described. The properties to be measured by such diagnostics are clearly identified and some results obtained with the installed diagnostics during d-d plasmas are presented.

61

The development of multiple probe microdialysis sampling in the stomach  

UK PubMed Central (United Kingdom)

A multiple probe approach of implanting microdialysis probes into each separate tissue layer would better represent sampling from the stomach. Presently, microdialysis sampling experiments are...Full Text Available

2008-09-10

62

Proton storage ring (PSR) diagnostics and control system  

Energy Technology Data Exchange (ETDEWEB)

When any new accelerator or storage ring is built that advances the state of the art, the diagnostic system becomes extremely important in tuning the facility to full specification. This paper will discuss the various diagnostic devices planned or under construction for the PSR and their connection into the control system.

1983-01-01

63

Characterizing Differential Air-Core Eddy Current Probes  

Science.gov (United States)

... Accession Number : ADD331250. Title : Characterizing Differential Air-Core Eddy Current Probes. Corporate Author : Personal ...

64

The Development of a Dental Diagnostic Terminology  

UK PubMed Central (United Kingdom)

There is no commonly accepted standardized terminology for oral diagnoses. The purpose of this article is to report the development of a standardized dental diagnostic terminology by a work...Full Text Available

2011-01-01

65

Transmit-receive eddy current probes for heat exchanger inspection  

International Nuclear Information System (INIS)

This paper describes various eddy current probes, and their performance, which were developed at the Chalk River Laboratories of Atomic Energy of Canada. Included are probes for detecting defects at tubesheet regions in heat exchanger tubes, defects at expansion-transition regions in finned tubes, and defects in ferromagnetic tubes. All of these probes can be used with conventional commercially available instruments. (author).

1987-09-01

67

Probing Neutron Star Evolution with Gamma Rays  

Science.gov (United States)

The research sponsored by this grant was conducted in two fields of high-energy astrophysics:

1996-01-01

68

Optic probe for semiconductor characterization  

Energy Technology Data Exchange (ETDEWEB)

Described herein is an optical probe (120) for use in characterizing surface defects in wafers, such as semiconductor wafers. The optical probe (120) detects laser light reflected from the surface (124) of the wafer (106) within various ranges of angles. Characteristics of defects in the surface (124) of the wafer (106) are determined based on the amount of reflected laser light detected in each of the ranges of angles. Additionally, a wafer characterization system (100) is described that includes the described optical probe (120).

2008-09-02

71

Field trial of a fast single-pass transmit-receive probe during Gentilly II steam generator tube inspection  

International Nuclear Information System (INIS)

A new generation of transmit-receive single-pass probes, denoted as C6 or X probe, was field tested during the Gentilly II, 2000 steam generator tube inspection. This probe has a performance equivalent to rotating probes and can be used for tubesheet and full-length inspection at an inspection speed equivalent to that of bobbin probes. Existing C3 transmit-receive probes have been demonstrated to be effective in detecting circumferential cracks. The C5 probe can detect both circumferential and axial cracks and volumetric defects but cannot discriminate between them. The C6 probe expands on the capabilities of both probes in a single probe head. It can simultaneously detect and discriminate between circumferential and axial cracks to satisfy different plugging criteria. It has ...

2000-11-19

73

Device for the inspection of curved pipes in steam raising units  

Energy Technology Data Exchange (ETDEWEB)

The chain of eddy current probes and a film cassette probe, which responds to radiation from a radio-active source in one of the heat exchanger pipes is examined. The probes are moved by nylon pipes on both ends of the chain through the pipe to be examined. The nylon pipes are bent off load. In this way the probes on the chain will adjust near to the plane of bending of the pipes to be tested.

1980-01-03

74

rf-driven ion sources for industrial applications (invited) (abstract)  

Science.gov (United States)

The Plasma and Ion Source Technology Group at the Lawrence Berkeley National Laboratory have been developing rf-driven ion sources for the last two decades. These sources are being used to generate both positive and negative ion beams. Some of these sources are operating in particle accelerators such as the Spallation Neutron Source (SNS) at Oak Ridge, while others are being employed in various industrial ion beam systems. There are four areas where the rf-driven ion sources are commonly used in industry. (1) In semiconductor manufacturing, rf-driven sources have found important applications in plasma etching, ion beam implantation, and ion beam lithography. (2) In material analysis and surface modification, miniature rf-ion sources can be found in focused ion beam systems. They can provide ion beams of essentially any element in the Periodic Table. The newly developed combined rf ion-electron beam unit improves greatly the performance of the secondary ion mass spectrometry tool. (3) ...

2008-02-15

75

Highly ordered thin films of polyheterocycles: A synchrotron radiation study of polypyrrole and polythiophene Langmuir-Blodgett films  

Energy Technology Data Exchange (ETDEWEB)

Langmuir-Blodgett films have been made with 3-n-hexadecylpyrrole and 3-n-octadecylpyrrole monomers and copolymers with unsubstituted pyrrole made by chemical polymerization at the air-water interface on a subphase containing FeCl/sub 3/. Langmuir-Blodgett films consisting of mixtures of stearic acid and alkylsubstituted polythiophenes have also been made as bilayer films. The orientation of single and multilayer films on platinum substrates have been studied by Near Edge X-ray Absorption Fine Structure Spectroscopy which also gives information about charge transfer interactions between the aromatic groups and the metallic substrates. The alkylsubstituted pyrroles form highly ordered two-dimensional structures. FeCl/sub 3/ initiated copolymerization with unsubstituted pyrrole leads to a more disordered system. In the case of polythiophene-stearic acid bilayers, the stearic acid layers are highly ordered. The poly(alkyl thiophene) layers ...

1988-01-01

79

ELECTRICAL AND DIAGNOSTIC ASPECTS OF ELECTROHYDRAULIC AND MAGNETIC FORMING  

Science.gov (United States)

Discussion of an electrohydraulic and magnetic forming process

1963-01-01

83

CT colonography. Virtual coloscopy; CT-Kolonographie. Virtuelle Koloskopie  

Energy Technology Data Exchange (ETDEWEB)

The CT colonography or virtual coloscopy is a new diagnostic method that allows the presentation of the whole colon using minimal invasive procedures. The method allows the detection of colorectal polyps and colorectal carcinomas. The book includes the following chapters: indications for CT colonography, diagnostic procedures, data processing and interpretation, diagnostic findings, preparation of the diagnostic result description and documentation, screening.

2009-07-01

85

Alternative Technologies for Medical Radionuclide Production  

International Science & Technology Center (ISTC)

Creation of Economic Alternative Technologies for Radionuclide Production for Medical Diagnostics and Therapy

86

Single parameter analysis of hysteretic magnetic flux trapping in high T{sub c} superconductor ribbon  

Energy Technology Data Exchange (ETDEWEB)

This paper described the application of an AC surface probe, similar to presently used eddy current probes, to the measurement of DC transport critical currents and critical state dissipation in high {Tc} superconductors. It has been shown that the probe can provide quantitative measurement of the full field penetration in superconducting samples by measuring the response of AC induced screening currents for superconducting materials in the form of tapes with overlayers of silver. In this manner, the AC probe can be used to replace the contact DC probe for determining critical currents in a noncontacting and local manner suitable for scanning over or along the sample.

1992-10-01

87

Single parameter analysis of hysteretic magnetic flux trapping in high T_c superconductor ribbon  

International Nuclear Information System (INIS)

This paper described the application of an AC surface probe, similar to presently used eddy current probes, to the measurement of DC transport critical currents and critical state dissipation in high T_c superconductors. It has been shown that the probe can provide quantitative measurement of the full field penetration in superconducting samples by measuring the response of AC induced screening currents for superconducting materials in the form of tapes with overlayers of silver. In this manner, the AC probe can be used to replace the contact DC probe for determining critical currents in a noncontacting and local manner suitable for scanning over or along the sample.

1992-07-19

88

Single parameter analysis of hysteretic magnetic flux trapping in high T[sub c] superconductor ribbon  

Energy Technology Data Exchange (ETDEWEB)

This paper described the application of an AC surface probe, similar to presently used eddy current probes, to the measurement of DC transport critical currents and critical state dissipation in high [Tc] superconductors. It has been shown that the probe can provide quantitative measurement of the full field penetration in superconducting samples by measuring the response of AC induced screening currents for superconducting materials in the form of tapes with overlayers of silver. In this manner, the AC probe can be used to replace the contact DC probe for determining critical currents in a noncontacting and local manner suitable for scanning over or along the sample.

1992-01-01

89

Spectroscopic investigation of tetracycline interaction with phospholipid Langmuir-Blodgett films  

Energy Technology Data Exchange (ETDEWEB)

A widely used veterinary antibiotic, tetracycline (TC), has been incorporated in Langmuir-Blodgett (LB) films of dipalmitoylphosphatidic acid (DPPA) by means of two different procedures: co-transfer and incubation in solution. The resulting structures were characterized by means of contact angle and ellipsometric measurements. The presence of the antibiotic in the phospholipid film was evidenced by means of UV-Vis electronic absorption and infrared vibrational spectroscopy. The two sets of measurements unambiguously indicated the presence of the drug in the LB layer films obtained with both methods, although incubation led to a smaller content of immobilized tetracycline. In both cases, the drug was found to reside in the hydrophilic portion of the layers due to specific interactions of the dimethylamino group of the molecule with the polar head groups of the phospholipid.

2002-12-01

90

Removal of reactive textile dyes (Remazol Brillant Blue R and Remazol Yellow) by surfactant-modified natural zeolite  

British Library Electronic Table of Contents (United Kingdom)

Abstract In this study, surfactant-modified zeolite (SMZ) was used to remove Remazol Brillant Blue R and Remazol Yellow reactive dyes from aqueous solutions. The influences of suspension pH, temperature, agitation rate, and the SMZ dosage on reactive dyes removal and adsorption capacity were investigated by conducting a series of batch adsorption experiments. The adsorption kinetics was tested for pseudo-first-order, pseudo-second order, intraparticle diffusion model, Elovich, and Bangham models, and rate constants of the kinetic models were calculated. Equilibrium isotherms for the adsorption of reactive dyes were analyzed by the Freundlich, Langmuir, Dubinin-Radushkevich, and Tempkin isotherm models. The Langmuir monolayer adsorption capacities of Remazol Brillant Blue R and Remazol Yell...

2011-01-01

91

Monolayers at air-water interfaces: from origins-of-life to nanotechnology  

British Library Electronic Table of Contents (United Kingdom)

Abstract The air-water interface presents several interesting features, namely a) a molecularly flat environment, b) a boundary region between two phases with different dielectric constants, c) permits or promotes dynamic interactions within the interface region, and d) a point of interaction between hydrophobic compounds and aqueous molecules. Accordingly, Langmuir monolayers at the air-water interface have several unique characteristics and properties, which require investigation. In this review-type personal account, typical examples of molecular recognition and molecular patterning at air-water interfaces are first introduced, followed by descriptions of specific and unusual properties of monolayers on water. In addition, two examples of our own results concerning Langmuir monolayers a...

2011-01-01

92

Irradiation of Langmuir-Blodgett multilayer preparations of phospholipids and a fatty acid. Pt. 1; Effect of UV radiation  

Energy Technology Data Exchange (ETDEWEB)

Langmuir-Blodgett (LB) preparations containing stacked monolayers of phospholipids or stearic acid were irradiated with UV light and the electric conductance perpendicular to the planes of the monolayers was measured. There was no observable change of conductance when LB preparations of stearic acid were irradiated. For LB preparations of phospholipids, a rise of conductance, dependent on dose rate, was observed, reaching an equilibrium level after a few hours. After irradiation the conductance fell with a temperature-dependent time constant, and eventually reached a final level a little above the initial value. A three-state model is proposed for the LB phospholipid preparations. This suggests that the absorption of one photon raises a molecule from the ground to an excited state; and the absorption of a second photon carries it into a damaged but repairable or metastable state. (author).

1992-12-01

93

Electrical properties of a calix[4]acid/amine Langmuir-Blodgett thin film  

British Library Electronic Table of Contents (United Kingdom)

In this work the DC and AC characteristics for metal-LB film-metal structures deposited by a standard Langmuir-Blodgett film deposition technique are investigated. The conduction mechanism has been studied for a thin film structure in which a calix[4]arene substituted with carboxylic acid groups has been deposited alternately with a calix[4]arene molecule substituted with amine groups. This LB film structure shows a typical insulating behaviour for low voltage values and the Schottky effect becomes dominant when the voltage increases. The conductivity at low voltage values was found to be 1.34x10^-^1^3Scm^-^1. The height of the potential barrier was determined to be 1.65eV for this alternate layer LB film system.

2011-01-01

94

Effect of headgroup dissociation on the structure of Langmuir monolayers  

Energy Technology Data Exchange (ETDEWEB)

The authors present results of grazing incidence X-ray diffraction studies concerning the effect of pH (and thus, of headgroup dissociation) on Langmuir monolayers of fatty acids, in the absence of any divalent cations in the aqueous subphase. An increase in pH transforms the distorted-hexagonal S phase first to the partially disordered Rotator-I phase with less distortion, and then to the completely disordered Rotator-II phase with an undistorted hexagonal structure. The S-Rotator-I and Rotator-I-Rotator-II transitions are pushed to lower temperatures with increase in pH. The fact that the effects of pH increase are almost identical to the effects of increasing temperature indicates the important role of headgroup-headgroup interactions in these monolayer phases.

2000-02-08

95

Die Einstellung von Simulated-Moving-Bed-Anlagen mit Hilfe des Coherence-Konzepts  

British Library Electronic Table of Contents (United Kingdom)

Fur die Trennung binarer Gemische wird zunehmend das Simulated Moving Bed (SMB)-Verfahren verwendet. Fur einen storungsfreien Betrieb mussen die Volumenstrome sowie die Umschaltzeit exakt eingestellt werden. In diesem Beitrag wird mit Hilfe des Coherence-Konzepts eine Methode aufgezeigt, mit der sich die Stellgroen fur einen dispersionsfreien SMB-Prozess bestimmen lassen. Fur Langmuir- und Anti-Langmuir-Isotherme konnen einfache explizite Gleichungen bei vollstandiger Trennung angegeben werden. Das Grundprinzip dieser Methode lasst sich auch auf andere Isotherme sowie fur die unvollstandige Trennung ubertragen.

2009-01-01

96

Alignment of nematic liquid crystals on mixed Langmuir-Blodgett mono-layers  

CERN Document Server

Mono-layers of stearic and behenic acids and mixtures of them in different proportions, deposited with the Langmuir-Blodgett technique, were used to study the alignment and the alignment dynamics in nematic liquid crystal cells. A relaxation process from a splay-bend flow induced metastable orientation to the homeotropic one occurs. The lifetime of the metastable state was found to depend on the mono-layer composition. The transition between the homeotropic and the conical anchoring was found to be irreversible in the case of the mixed aligning mono-layers: on cooling from the isotropic phase a quasi-planar nematic state (schlieren texture) appears. It is stable in a range of a few degrees below the clearing point and, on decreasing the temperature, relaxes to the homeotropic state in form of expanding domains.

1998-01-01

97

Alignment and alignment dynamics of nematic liquid crystals on Langmuir-Blodgett mono-layers  

CERN Document Server

Mono-layers of stearic and behenic acids deposited with the Langmuir-Blodgett technique, were used as aligning films in nematic liquid crystal cells. During the filling process the liquid crystal adopts a deformed quasi-planar alignment with splay-bend deformation and preferred orientation along the filling direction. This state is metastable and transforms with time into homeotropic once the flow has ceased. The transition is accompanied by formation of disclination lines which nucleate at the edges of the cell. The lifetime of the metastable splay-bend state was found to depend on the cell thickness. On heating, anchoring transition from quasi-homeotropic to degenerate tilted alignment in form of circular domains takes place near the transition to the isotropic phase. The anchoring transition is reversible with a small hysteresis.

1998-01-01

98

Adsorption rate of phenol from aqueous solution onto organobentonite: Surface diffusion and kinetic models.  

Science.gov (United States)

The concentration decay curves for the adsorption of phenol on organobentonite were obtained in an agitated tank batch adsorber. The experimental adsorption rate data were interpreted with diffusional models as well as first-order, second-order and Langmuir kinetic models. The surface diffusion model adjusted the data quite well, revealing that the overall rate of adsorption was controlled by surface diffusion. Furthermore, the surface diffusion coefficient increased raising the mass of phenol adsorbed at equilibrium and was independent of the particle diameter in the range 0.042-0.0126cm. It was demonstrated that the overall rate of adsorption was essentially not affected by the external mass transfer. The second-order and the Langmuir kinetic models fitted the experimental data quite well; however, the kinetic constants of both models varied without any physical meaning while increasing the particle size and the mass of phenol adsorbed at ...

2011-08-22

99

Computer modelling of eddy current probes  

International Nuclear Information System (INIS)

Computer programs have been developed for modelling impedance and transmit-receive eddy current probes in two-dimensional axis-symmetric configurations. These programs, which are based on analytic equations, simulate bobbin probes in infinitely long tubes and surface probes on plates. They calculate probe signal due to uniform variations in conductor thickness, resistivity and permeability. These signals depend on probe design and frequency. A finite element numerical program has been procured to calculate magnetic permeability in non-linear ferromagnetic materials. Permeability values from these calculations can be incorporated into the above analytic programs to predict signals from eddy current probes with permanent magnets in ferromagnetic tubes. These programs were used to test various probe designs for new testing applications. ...

1992-10-01

100

Evaluation of surgical gamma probes for sentinel node localisation in cervical and vulvar cancer  

International Nuclear Information System (INIS)

Sentinel node (SN) scintigraphy for cervical and vulvar cancer guides the gynaecological oncologist in finding the metastatic lymph nodes during lymphadenectomy. The role of the surgical gamma probe in the sentinel node concept in gynaecological oncology is to localise (SN) both intra-operatively and transcutaneously. Intra-operative hand-held collimated gamma probes are increasingly used for detection of the sentinel lymph node. A comparative evaluation of handheld gamma probes: Neoprobe 1500, Europrobe, Gamma Finder, Gamma Ray Prospector GRP1 and GPR2 was performed using different detection methods. Laboratory tests were performed in which sensitivity, spatial resolution and angular sensitivity were evaluated. The results for each gamma probe were summarised and discussed. Awareness of a gamma probes capabilities and limitations should be considered in the appropriate selection of ...

101

Diagnostics hardening for harsh environment in Laser Megajoule (invited)  

International Nuclear Information System (INIS)

The diagnostic designs for the Laser Megajoule (LMJ) will require components to operate in environments far more severe than those encountered in present facilities. This harsh environment will be induced by fluxes of neutrons, gamma rays, energetic ions, electromagnetic radiations, and, in some cases, debris and shrapnel, at levels several orders of magnitude higher than those experienced today on existing facilities. The lessons learned about the vulnerabilities of present diagnostic parts fielded mainly on OMEGA for many years, have been very useful guide for the design of future LMJ diagnostics. The present and future LMJ diagnostic designs including this vulnerability approach and their main mitigation techniques will be presented together with the main characteristics of the LMJ facility that provide for diagnostic protection.

2008-10-01

102

Diagnostic quality in hysterosalpingography  

International Nuclear Information System (INIS)

Purpose: To compare the diagnostic quality and adverse events of the water-soluble, non-ionic, iso-osmolar, dimeric contrast media iodixanol and iotrolan in hysterosalpingography (HSG). Material and Methods: One hundred and twenty patients participated in a double-blind randomized parallel-group phase-III study. Questionnaires and patient interviews were used. Diagnostic quality was assessed using a visual analogue scale and the quality in specific regions was rated using a categorical scale. Results: Overall diagnostic quality was equal for the two groups. There was no statistically significant difference between the two groups in diagnostic quality in the specific regions of interest. No differences between the contrast media were found with regard to adverse events. Conclusion: Both contrast media provided images of high diagnostic quality in HSG. (orig.)

1998-11-01

103

Transmit-receive eddy current probes for circumferential cracks in heat exchanger tubes  

Energy Technology Data Exchange (ETDEWEB)

Conventional eddy current bobbin probes are known to be ineffectual in detecting circumferential cracks in tubing. Multi-pancake and/or rotating pancake probes are required to detect circumferential cracks. It has recently been demonstrated in CANDU steam generator tubes, with deformation, ferromagnetic deposits, and copper deposits, that multi-channel probes with transmit-receive (T/R) coils are superior to those using surface impedance coils. Unlike rotating probes, the design of a new probe denoted as C3 permits fast, single-scan inspection of a full-length tube at inspection speeds comparable to conventional bobbin probes. Since 1992, the probe has been used routinely for steam generator in-service inspection at 4 CANDU plants. Defective tubes have been plugged and the units returned to service, and they continue to operate without ...

1996-01-01

104

Transmit-receive eddy current probes for circumferential cracks in heat exchanger tubes  

International Nuclear Information System (INIS)

Conventional eddy current bobbin probes are known to be ineffectual in detecting circumferential cracks in tubing. Multi-pancake and/or rotating pancake probes are required to detect circumferential cracks. It has recently been demonstrated in CANDU steam generator tubes, with deformation, ferromagnetic deposits, and copper deposits, that multi-channel probes with transmit-receive (T/R) coils are superior to those using surface impedance coils. Unlike rotating probes, the design of a new probe denoted as C3 permits fast, single-scan inspection of a full-length tube at inspection speeds comparable to conventional bobbin probes. Since 1992, the probe has been used routinely for steam generator in-service inspection at 4 CANDU plants. Defective tubes have been plugged and the units returned to service, and they continue to operate without ...

1992-01-01

105

National NIF Diagnostic Program Fiscal Year 2002 Second Quarter Report  

Energy Technology Data Exchange (ETDEWEB)

Since October 2001 the development of the facility diagnostics for NIF has been funded by the NIF Director through the National NIF Diagnostic Program (NNDP). The current emphasis of the NNDP is on diagnostics for the early NIF quad scheduled to be available for experiment commissioning in FY03. During the past six months the NNDP has set in place processes for funding diagnostics, developing requirements for diagnostics, design reviews and monthly status reporting. Those processes are described in an interim management plan for diagnostics (''National NIF Diagnostic Program Interim Plan'', NIF-0081315, April 2002) and a draft Program Execution Plan (''Program Execution Plan for the National NlF Diagnostic Program'', NIF-0072083, October 2001) and ...

2002-04-01

106

chipD: a web tool to design oligonucleotide probes for high-density tiling arrays  

UK PubMed Central (United Kingdom)

chipD is a web server that facilitates design of DNA oligonucleotide probes for high-density tiling arrays, which can be used in a number of genomic applications such as ChIP-chip or gene-expression...Full Text Available

2010-07-01

107

Use of synthetic oligoribonucleotides to probe RNA-protein interactions in the MS2 translational operator complex.  

UK PubMed Central (United Kingdom)

Synthetic oligoribonucleotides have been used to probe the interaction of MS2 coat protein with the translational operator of the MS2 replicase gene. We have investigated the possible formation of a...Full Text Available

1990-06-25

108

Use of synthetic oligonucleotide DNA probes for identification and direct detection of Bacteroides forsythus in plaque samples.  

UK PubMed Central (United Kingdom)

Oligonucleotide DNA probes complementary to the hypervariable region of the 16S rRNA of Bacteroides forsythus were tested for their specificity and sensitivity against reference and clinical isolates...Full Text Available

1991-10-01

109

Use of an alkaline phosphatase-labeled synthetic oligonucleotide probe for detection of Campylobacter jejuni and Campylobacter coli.  

UK PubMed Central (United Kingdom)

A commercially available synthetic nucleic acid probe (SNAP) conjugated to alkaline phosphatase was compared with standard culture techniques for detecting Campylobacter species. The SNAP was able to...Full Text Available

1990-07-01

110

Rapid aneuploidy detection with multiplex ligation-dependent probe amplification: a prospective study of 4000 amniotic fluid samples  

UK PubMed Central (United Kingdom)

The introduction of prenatal screening requires rapid high-throughput diagnosis of common aneuploidies. Multiplex ligation-dependent probe amplification (MLPA) allows for quick, easily automated multiplex...Full Text Available

2009-01-01

111

Near Infrared-Fluorescent and Magnetic Resonance Imaging Molecular Probe with High T1 Relaxivity for In Vivo Multimodal Imaging  

UK PubMed Central (United Kingdom)

A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.

2010-06-07

112

Improved eddy-current inspection for steam generator tubing  

Energy Technology Data Exchange (ETDEWEB)

Computer programs have been written to allow the analysis of different types of eddy-current probes and their performance under different steam generator test conditions. The probe types include the differential bobbin probe, the absolute bobbin probe, the pancake probe and the reflection probe. The generator test conditions include tube supports, copper deposits, magnetite deposits, denting, wastage, pitting, cracking and IGA. These studies are based mostly on computed values, with the limited number of test specimens available used to verify the computed results. The instrument readings were computed for a complete matrix of the different test conditions, and then the test conditions determined as a function of the readings by a least-squares technique. A comparison was made of the errors in fit and instrument drift for the different probe ...

1989-01-01

113

Field experience with eddy current X-probes in CANDU steam generators and heat exchangers  

Energy Technology Data Exchange (ETDEWEB)

CANDU steam generators and heat exchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if not all of the functions of the other tube-testing eddy current ...

2006-07-01

114

Field experience with eddy current X-probes in CANDU steam generators and heat exchangers  

International Nuclear Information System (INIS)

CANDU steam generators and heat exchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if not all of the functions of the other tube-testing eddy current ...

2005-11-20

115

Eddy Current Inspection of Mildly Ferromagnetic Tubing.  

Science.gov (United States)

The past decade has seen the development of eddy current probes for inspection of the mildly ferro-magnetic alloy Monel 400. Due to the rapid advances in permanent magnet technology similar probes have been upgraded to magnetically saturate, and hence ins...

1984-01-01

116

Detection and Analysis of Tumor Fluorescence Using a Two-Photon Optical Fiber Probe  

UK PubMed Central (United Kingdom)

The utility of a two-photon optical fiber fluorescence probe (TPOFF) for sensing and quantifying tumor fluorescent signals was tested in vivo. Xenograft tumors were developed in athymic mice using MCA207...Full Text Available

2004-06-01

117

5-Fluorodeoxyuridine as an alternative to the synthesis of mixed hybridization probes for the detection of specific gene sequences.  

UK PubMed Central (United Kingdom)

Synthetic complementary oligonucleotides are useful hybridization probes for the detection of mRNAs and genes encoding proteins for which only a partial amino acid sequence is known. Usually this involves...Full Text Available

1988-03-01

118

Glass Furnace Combustion and Melting Research Facility.  

Energy Technology Data Exchange (ETDEWEB)

The need for a Combustion and Melting Research Facility focused on the solution of glass manufacturing problems common to all segments of the glass industry was given high priority in the earliest version of the Glass Industry Technology Roadmap (Eisenhauer et al., 1997). Visteon Glass Systems and, later, PPG Industries proposed to meet this requirement, in partnership with the DOE/OIT Glass Program and Sandia National Laboratories, by designing and building a research furnace equipped with state-of-the-art diagnostics in the DOE Combustion Research Facility located at the Sandia site in Livermore, CA. Input on the configuration and objectives of the facility was sought from the entire industry by a variety of routes: (1) through a survey distributed to industry leaders by GMIC, (2) by conducting an open workshop following the OIT Glass Industry Project Review in September 1999, (3) from discussions with numerous glass engineers, scientists, and executives, and (4) ...

2004-08-01

119

Synchrotron Probes of Emergent Electronic States of Matter in Solids  

ScienceCinema

...of this article he quotes um i am told by my english ...

120

Some Properties of Australian Produced Explosive ...  

Science.gov (United States)

... The rounds were initiated by an exploding bridgewire detonator (EBW) and the ionisation probes were progressively cloud by the detonation front. ...

1987-10-01

121

Signal simulator for the calibration of eddy current probes  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a signal simulator which is designed to calibrate eddy current probes. By using simultaneously an excitation coil and an electrically conducting plane, the simulator can emulate signals which correspond to spot welds with different flaws. The presence of a conducting plane allows a wide variation of the amplitude and phase of the excitation coil voltage during the calibration of a probe. A mathematical model for the simulator is derived and used to study the variation of the impedance change upon the parameters of the probe. Numerical computation shows that the impedance change depends in an important way on the frequency of the excitation coil current.

1994-01-01

123

EFFECTS OF SHIELDING ON PROPERTIES OF EDDY ...  

Science.gov (United States)

... Accession Number : ADD323869. Title : EFFECTS OF SHIELDING ON PROPERTIES OF EDDY CURRENT PROBES WITH FERRITE CUP CORES. ...

1986-08-01

124

EDDY CURRENT SIZING OF CASE DEPTH IN BEARING ...  

Science.gov (United States)

... HARDENED CUP AND CARBURIZED AND HARDENED CORES HAVE BEEN PROFILED USING 2 TYPES OF EDDY CURRENT PROBES. ...

1986-07-01

125

Validity of Cardiac Markers as Diagnostic and Prognostic Indicators of Complications in Patients undergoing Percutaneous Coronary Intervention  

UK PubMed Central (United Kingdom)

ObjectivesThe aim of this study was to assess the diagnostic and prognostic value of heart-type fatty acid-binding protein (H-FABP) in elective percutaneous coronary intervention...Full Text Available

2010-04-01

126

Simple fractal method of assessment of histological images for application in medical diagnostics  

UK PubMed Central (United Kingdom)

We propose new method of assessment of histological images for medical diagnostics. 2-D image is preprocessed to form 1-D landscapes or 1-D signature of the image contour and then their complexity is...Full Text Available

127

SNQ for medical research  

Energy Technology Data Exchange (ETDEWEB)

The planned spallation source can be of considerable significance for biomedical basic research and for clinically relevant diagnostic and therapeutic applications. The following gives a brief description and explanations for its possible use in clinical medicine: I. Treatment of Malignant Tumors II. Production of Isotopes for Biochemical Investigations in Living Organisms for Diagnostic Purposes.

1984-12-01

128

Reduction of anti-malarial consumption after rapid diagnostic tests implementation in Dar es Salaam: a before-after and cluster randomized controlled study  

UK PubMed Central (United Kingdom)

BackgroundPresumptive treatment of all febrile patients with anti-malarials leads to massive over-treatment. The aim was to assess the effect of implementing malaria rapid diagnostic...Full Text Available

129

Perceived association between diagnostic and non-diagnostic cues of women's sexual interest: General Recognition Theory predictors of risk for sexual coercion  

UK PubMed Central (United Kingdom)

Young men's errors in sexual perception have been linked to sexual coercion. The current investigation sought to explicate the perceptual and decisional sources of these social perception errors,...Full Text Available

2010-01-01

130

Factors underlying diagnostic delay in tuberculosis patients in a rural area in Tanzania: a qualitative approach  

UK PubMed Central (United Kingdom)

BackgroundDiagnostic delay in patients with tuberculosis (TB) leads to ongoing TB transmission, higher mortality rates and increased patient and government health expenditure. Qualitative...Full Text Available

2010-12-01

131

Diagnostic comparison of malaria infection in peripheral blood, placental blood and placental biopsies in Cameroonian parturient women  

UK PubMed Central (United Kingdom)

BackgroundIn sub-Saharan Africa, Plasmodium falciparum malaria in pregnancy presents an enormous diagnostic challenge. The epidemiological and clinical relevance...Full Text Available

132

Diagnostic Performance of Computed Tomography Colonography in Symptomatic Patients and in Patients with Increased Risk for Colorectal Disease  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate the diagnostic performance (colorectal lesions) of computed tomography (CT) colonography in 111 patients, a majority of whom were at high risk for colorectal neoplasia. Material and Methods: After bowel preparation, CT colonography was performed, immediately followed by conventional colonoscopy. The diagnostic performance of CT colonography was analyzed relative to lesion size, histological diagnosis, and diagnostic certainty. Results: The sensitivity of CT colonography increased with lesion size (P<0.001), and was 91% (21/23) for lesions > or = 10 mm. All 10 carcinomas and 86% (19/22) of adenomas > or = 5 mm were detected. Unconfirmed or false-positive CT findings were generally small and/or reported with low diagnostic certainty. The specificity of CT colonography would be 45% (30/66; 95% CI 34% to 57%) if patients with findings of any size and any ...

2006-11-15

133

Biological, Life Course, and Cross-Cultural Studies All point Toward the Value of Dimensional and Developmental Ratings in the Classification of Psychosis  

UK PubMed Central (United Kingdom)

The diagnostic criteria for schizophrenia in the fourth edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-IV1)...Full Text Available

2007-07-01

134

Assessment of the value of various tomography modalities for diagnostic evaluation of the female genital system  

International Nuclear Information System (INIS)

The comprehensive survey explains the indications and the specific value of the modern tomographic modalities with respect to the various diagnostic issues. Numerous reproductions of CT, MRI, US scans illustrate the aspects discussed. (orig./CB)

2001-09-01

135

Age-Stratified Bayesian Analysis To Estimate Sensitivity and Specificity of Four Diagnostic Tests for Detection of Cryptosporidium Oocysts in Neonatal Calves?  

UK PubMed Central (United Kingdom)

There is no gold standard diagnostic test for the detection of bovine cryptosporidiosis. Infection is usually highest in 2-week-old calves, and these calves also excrete high numbers of oocysts. These...Full Text Available

2011-01-01

136

A simple nomogram for sample size for estimating sensitivity and specificity of medical tests  

UK PubMed Central (United Kingdom)

Sensitivity and specificity measure inherent validity of a diagnostic test against a gold standard. Researchers develop new diagnostic methods to reduce the cost, risk, invasiveness, and time. Adequate...Full Text Available

2010-11-01

137

THE EVOLUTION OF THE STAR FORMATION RATE OF GALAXIES AT 0.0 #<=# z #<=# 1.2  

International Nuclear Information System (INIS)

We present the 24 #mu#m rest-frame luminosity function (LF) of star-forming galaxies in the redshift range 0.0 #<=# z #<=# 0.6 constructed from 4047 spectroscopic redshifts from the AGN and Galaxy Evolution Survey of 24 #mu#m selected sources in the Booetes field of the NOAO Deep Wide-Field Survey. This sample provides the best available combination of large area (9 deg"2), depth, and statistically complete spectroscopic observations, allowing us to probe the evolution of the 24 #mu#m LF of galaxies at low and intermediate redshifts while minimizing the effects of cosmic variance. In order to use the observed 24 #mu#m luminosity as a tracer for star formation, active galactic nuclei (AGNs) that could contribute significantly at 24 #mu#m are identified and excluded from our star-forming galaxy sample based on their mid-IR spectral energy distributions or the detection of X-ray emission. Optical emission line diagnostics are considered for ...

2010-08-01

138

Damage process and luminescent characteristics in silica glasses under ion irradiation  

International Nuclear Information System (INIS)

Full text of publication follows: Understanding the dynamic irradiation effects on silica glasses is important for developing the diagnostic systems used in fusion and fission environments. While fundamental defects having an un-pared electron such as the E' center have been extensively studied, the neutral oxygen deficiency defects have been insufficiently clarified for lack of the detection methods. The ion induced luminescence is one of the probes that can be used to detect non-paramagnetic defects, and to observe creation and annihilation behavior dynamically. In the present study, we examined the characteristics of the ion induced luminescence such as energy, fluence flux and temperature dependence of the luminescence efficiency to analyze damage process quantitatively. Samples of SiO2 glasses were commercially available fused and synthesized silica glasses, produced by Toshiba Ceramics, Co. Ltd.. A thin films of SiO2 deposited on a Si ...

2007-12-10

139

Simultaneous absolute and differential operation of eddy current bobbin probes for heat exchanger tube inspection  

Energy Technology Data Exchange (ETDEWEB)

Here the authors try to dissolve some commonly held misconceptions about the operation of eddy current probes used for inspecting heat exchanger tubes. With the help of computer model results, the authors demonstrate that, for optimized operation, absolute/differential probes should be operated with coil current flowing in phase with another. This month's feature should be of interest to researchers as well as for NDT field personnel.

2000-05-01

140

Evaluation of phased array UT conditions using ultrasonic visualization technique  

International Nuclear Information System (INIS)

Phased array provides many advantages over conventional ultrasonic testing method, but phased array has also limitations. This paper describes typical results of the experimental sound field analysis generated from the array probe. A photo-elastic ultrasonic visualization technique was applied in this study. The sound fields of shear wave generated from the array probe was equivalent to that from the fixed angle probe. (author)

2008-07-01

141

Array coil probe design optimization  

International Nuclear Information System (INIS)

To overcome the limitations of conventional bobbin style eddy-current probes, it has become common practice to perform some portion of a steam generator tube inspection program with array coil probes. Typically, eight surface-riding pancake coils are utilized in a probe head, either as eight independent coils (8 x 1) or in a parallel combination of four serially connected coils (4 x 4). The advantages of the array coils are improved sensitivity to intergranular attack (IGA), reduced interference from tube denting, and improved sensitivity to circumferential cracking. The current status of commercially available probes is such that several weaknesses in array coils have limited the widespread application of this technology. Task S 301-6 was conceived to address each of the weaknesses in order to produce a more reliable and cost-effective probe. The emphasis was on reliability, since ...

1987-07-01

145

Plasma diagnostics in the optical and X-ray regions on the plasma focus device PF-4 (TULIP)  

International Nuclear Information System (INIS)

... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,

2006-09-11

146

Investigating Models of Social Development Using a ...  

Science.gov (United States)

... taker', Adaptive Behavior. In submission. Behavioral Disorders: Diagnostic Criteria for Re- Breazeal (Ferrell), C. (1998), A Motivational System for ...

2011-05-13

147

Methods and results of a representative analysis of the radiation exposure of the population by diagnostic radiology  

International Nuclear Information System (INIS)

From the frequency of diagnostic radiologic examinations and their radiation dose delivered to the population the risk of cancer induction and genetic damage is calculated on the basis of the risk factors given by the ICRP. Thus 0.38 % and 3 % of the total mortality for cancer and leukemia, resp., can be attributed to X-ray diagnostics. Chest examinations alone result in 0.07-0.7 damages per 100,000 persons depending on the imaging technique applied. (author).

1984-01-01

148

Special eddy current probes for heat exchanger inspection  

International Nuclear Information System (INIS)

Until a decade ago, only the differential bobbin type eddy current probe was considered necessary for reliable heat exchanger tube inspection. The introduction of different tube materials, manufacturing processes and a variety of service induced failures has greatly increased the demands of eddy current testing. Optimized probe designs enhanced by improved instrumentation can help satisfy some of these demands. Some of the more difficult inspection problems are detection of circumferential cracks, fretting wear under non-ferromagnetic support plates and shallow internal defects. Reliable detection and sizing of such defects is often made more difficult by the fact they frequently occur in defect prone regions such as under tubesheets or support plates and in transition regions of finned tubes. Probe designs effective in overcoming these difficulties exist. This paper describes a number of such probes ...

1986-11-17

149

Mathematical modeling of x-probe eddy current array coils used in tube inspection  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a mathematical model that calculates eddy current signals from laterally spaced transmit-receive pancake coils. This model was validated by comparing calculations with laboratory measurements and it has been applied to evaluating design variations in X-Probe eddy current array coils. This model was used to quantify detection capabilities of probe designs with different numbers of coils. The current standard X-Probe design for 13 mm (0.5 inch) diameter steam generator tubes uses 3 rows of coils with 8 coils per row. This design is commonly referred to as the '8 coil X-Probe'. A significant improvement in detection capability was predicted for an X-Probe with 12 coils per row (called the '12 coil X-Probe') detecting short circumferential crack-like flaws. Based on these calculations, a prototype 12 coil ...

2004-11-15

150

Characteristics Testing of the ECT Bobbin Probe for S/G Tube Inspection  

Energy Technology Data Exchange (ETDEWEB)

The bobbin probe technique is basically one of the important ECT methods for the steam generator tube integrity assessment that is practiced during each plant outage. The bobbin probe also is the essential component which consists of the whole ECT examination system, and provides a decisive data for the evaluation of tube integrity in compliance with acceptance criteria described in specific procedures. The selection of probe is especially important because the quality of acquired ECT data is determined by the probe design characteristics, such as geometry and operation frequency, and has an important effect on examination results. The Electric Power Research Institute (EPRI) has recently defined the procedures for the qualification of eddy current hardware and technique. These procedures provide two basic methods for qualification. Flawed tube removed from operation, or artificial flaw is required for ...

2010-05-15

151

Characteristics Testing of the ECT Bobbin Probe for S/G Tube Inspection  

International Nuclear Information System (INIS)

The bobbin probe technique is basically one of the important ECT methods for the steam generator tube integrity assessment that is practiced during each plant outage. The bobbin probe also is the essential component which consists of the whole ECT examination system, and provides a decisive data for the evaluation of tube integrity in compliance with acceptance criteria described in specific procedures. The selection of probe is especially important because the quality of acquired ECT data is determined by the probe design characteristics, such as geometry and operation frequency, and has an important effect on examination results. The Electric Power Research Institute (EPRI) has recently defined the procedures for the qualification of eddy current hardware and technique. These procedures provide two basic methods for qualification. Flawed tube removed from operation, or artificial flaw is required for ...

2010-05-01

152

Research and development on probe inserting method into steam generator helically coiled tubes for in-service inspection  

International Nuclear Information System (INIS)

Helically coiled tubes of steam generators (SG) in FBR are boundaries between sodium and water/steam. Therefore, to assure the integrity of tubes, it is necessary to inspect the tubes nondestructively for in service or after a sodium-water reaction accident. In order to make it possible to conduct in-service inspection of SG tubes, we have studied on eddy current probes and probe inserting methods. As for the probe inserting method, IHI designed a fluid driving type which consists of a model probe and signal cable with float balls and driven by air pressure force. Presented in this paper is the authors' report, which describes the fluid driving type as an effective method to insert an eddy current probe into helically coiled tubes. The outline of the test results is as follows: 1. It was possible to insert the probe into 65 meter length helically coiled tubes. ...

1979-01-01

153

Performance evaluation of corrosion probes in simulated WVNS tank 8D-2 waste: WVNS tank farm process support  

Energy Technology Data Exchange (ETDEWEB)

Five corrosion probes were received from West Valley Nuclear Services for evaluation in simulated tank 8D-2 3rd-stage sludge wash slurry. The same waste slurry simulated was also used in a series of ongoing corrosion studies assessing the effects of in-tank sludge washing on the integrity of tank 8D-2. Two of the corrosion probes were installed in the coupon corrosion test vessels operating at {approximately}150{degrees}F to compare performance of the probes with that observed by coupon tests conducted in the same vessels. Corrosion rate data calculated from electrical resistance measurements of the corrosion probes were evaluated for this study using two slightly different approaches. One approach uses the total length of exposure of the probe to give a ``time-averaged`` value of the corrosion rate. The other approach uses a shorter period of time (relative to the length of the ...

1994-07-01

154

Improvement of detectability for circumferential crack of Steam Generator tube by eddy current and ultrasonic testing method  

International Nuclear Information System (INIS)

Steam Generator (SG) tubes in PWR plant are periodically inspected using eddy current testing (ECT) method. In Japan, bobbin coil type dual function probe is used for full length inspection, but the detectability for circumferential crack is very poor, and to improve detectability for circumferential crack and supplement regular ECT, various kinds of multi segment eddy current probes and multi transducer ultrasonic testing (UT) method have been developed. ECT probes are constructed of multiple surfaceriding special winding differential type coils and UT probe consists of 16 transducers which are spaced equally around the probe circumference for 360deg wall coverage. Both of those EC and UT probes are designed effective to detect circumferential crack. On the other hand, various kinds of laboratory induced circumferential cracks have been made and destroyed to ...

1991-08-01

155

The CO{sub 2} gasification kinetics of olive residue  

Energy Technology Data Exchange (ETDEWEB)

Orujillo, sometimes called wood matter from pressed oil-stone (WPOS) is a residue from the olive oil mill industry. The generation of this biomass residue is concentrated in small areas allowing its use as fuel for medium size gasification and combustion plants. Rates of gasification of WPOS char were measured in a TGA at various temperatures (800-850-875-900-950{sup o}C), CO{sub 2} partial pressures (0.20-0.35-0.50 bar) and CO partial pressures (0.0-0.20 bar). The experiments were carried out with a monolayer bed of very fine particles well exposed to the gas so as to minimise mass and heat transfer resistances. Two kinetic models, the nth order model and Langmuir-Hinshelwood model, have been used to fit with the reactivity data. For pure CO{sub 2} experiments the kinetic parameters of nth order model were E=133 kJ/mol and n=0.43. The Langmuir-Hinshelwood kinetic model clearly describes the observed CO inhibition effect on the CO{sub 2} ...

2003-02-01

156

Selecting soil amendment materials for removal of phosphorus  

Energy Technology Data Exchange (ETDEWEB)

Phosphorus sorption capacities of several different materials including Merribrook soil (a loamy sand) and some industrial solid wastes (red mud neutralized with gypsum, fly ash, bottom ash and black oxide) were determined in sorption isotherms by Langmuir and Freundlich equations. The materials were characterized by bulk density, particle density, total porosity and particle size distributions. Red mud gypsum possessed the best sorption capacity based on the Langmuir maxima. Alkaline fly ash and Merribrook soil had lower sorption maxima compared to the red mud gypsum. Bottom ash and acidic fly ash had very low sorption capacity at low concentrations. Merribrook soil had the highest hydraulic conductivity. The results suggested that alkaline fly ash may be a promising amendment for coarse sand bed to enhance phosphorus removal. Merribrook soil appears to be suitable for on-site wastewater treatment.

1994-12-31

157

Kinetic and isotherm studies of Cu(II) biosorption onto valonia tannin resin  

Energy Technology Data Exchange (ETDEWEB)

The biosorption of Cu(II) from aqueous solutions by valonia tannin resin was investigated as a function of particle size, initial pH, contact time and initial metal ion concentration. The aim of this study was to understand the mechanisms that govern copper removal and find a suitable equilibrium isotherm and kinetic model for the copper removal in a batch reactor. The experimental isotherm data were analysed using the Langmuir, Freundlich and Temkin equations. The equilibrium data fit well in the Langmuir isotherm. The experimental data were analysed using four sorption kinetic models - the pseudo-first- and second-order equations, the Elovich and the intraparticle diffusion model equation - to determine the best fit equation for the biosorption of copper ions onto valonia tannin resin. Results show that the pseudo-second-order equation provides the best correlation for the biosorption process, whereas the Elovich equation also fits the ...

2009-03-15

158

Impact of kerogen heterogeneity on sorption of organic pollutants. 2. Sorption equilibria  

Energy Technology Data Exchange (ETDEWEB)

Phenanthrene and naphthalene sorption isotherms were measured for three different series of kerogen materials using completely mixed batch reactors. Sorption isotherms were nonlinear for each sorbate-sorbent system, and the Freundlich isotherm equation fit the sorption data well. The Freundlich isotherm linearity parameter n ranged from 0.192 to 0.729 for phenanthrene and from 0.389 to 0.731 for naphthalene. The n values correlated linearly with rigidity and aromaticity of the kerogen matrix, but the single-point, organic carbon-normalized distribution coefficients varied dramatically among the tested sorbents. A dual-mode sorption equation consisting of a linear partitioning domain and a Langmuir adsorption domain adequately quantified the overall sorption equilibrium for each sorbent-sorbate system. Both models fit the data well, with r{sup 2} values of 0.965 to 0.996 for the Freundlich model and 0.963 to 0.997 for the dual-mode model for the phenanthrene ...

2009-08-15

159

Equilibrium, kinetics and thermodynamic studies on phosphate biosorption from aqueous solutions by Fe(III)-treated Staphylococus xylosus biomass: Common ion effect  

British Library Electronic Table of Contents (United Kingdom)

The biosorption of phosphate from aqueous solutions using Fe(III)-treated Staphylococus xylosus cells was investigated. Langmuir and Freundlich isotherm models were applied to describe the adsorption equilibrium and found that Langmuir isotherm model fitted the equilibrium data better than Freundlich isotherm model. The biosorption capacity of Fe(III)-treated biomass for phosphate was found to be 70.92mg/g at optimum conditions of pH 3.0, biomass concentration 0.5g/L and equilibrium phosphate-biomass time 60min respectively. The sorption efficiency at initial phosphate concentration of 50mg/L was not influenced upon addition of SO4^2^-, Cl^-, CO3^2^-, NO3^-, Mg^2^+ and Ca^2^+ ions from 0 to 800mg/L, whereas under the same conditions, phosphate sorption was increased with increase in concen...

2011-01-01

160

Equilibrium and thermodynamic parameters of single and binary mixture biosorption of lead (II) and copper (II) ions onto Pseudomonas putida: Effect of temperature  

Energy Technology Data Exchange (ETDEWEB)

The biosorption of lead (II) and copper (II) ions, single component and binary systems, by dried P. putida was investigated in a batch system. The effects of initial pH, temperature, initial single and binary mixture concentrations on the biosorption kinetics and equilibrium uptake of each component, both single and binary mixtures were investigated. The bacterial biomass exhibited the highest single and binary lead (II) and copper (II) ions uptake capacity at 25 and 30 deg. C, respectively, the initial pH value of 5.5 and at the initial metal ions concentration of 100 mg dm{sup -3}. The Freundlich and Langmuir adsorption models were used for the mathematical description of the biosorption equilibrium and isotherm constants were evaluated at different temperatures. Adsorption data were well described by the Langmuir model, although they could be modeled by the Freundlich equation. The thermodynamics constants of the adsorption process: ...

2006-07-31

161

Equilibrium and kinetic studies for the biosorption system of copper(II) ion from aqueous solution using Tectona grandis L.f. leaves powder  

Energy Technology Data Exchange (ETDEWEB)

The biosorption of copper(II) ions from aqueous solution by Tectona grandis L.f. was studied in a batch adsorption system as a function of pH, metal ion concentration, adsorbent concentration and adsorbent size. The biosorption capacities and rates of copper(II) ions onto T. grandis L.f. were evaluated. The Langmuir, Freundlich, Redlich-Peterson and Temkin adsorption models were applied to describe the isotherms and isotherm constants. Biosorption isothermal data could be well interpreted by the Langmuir model with maximum adsorption capacity of 15.43 mg/g of copper(II) ion on T. grandis L.f. leaves powder. The kinetic experimental data properly correlated with the second-order kinetic model. Various thermodynamic parameters such as {delta}G{sup o}, {delta}H{sup o}, and {delta}S{sup o} were calculated indicating that this system was a spontaneous and exothermic process.

2006-09-21

162

Biosorption of total chromium from aqueous solution by red algae (Ceramium virgatum): Equilibrium, kinetic and thermodynamic studies  

Energy Technology Data Exchange (ETDEWEB)

This study focused on the biosorption of total chromium onto red algae (Ceramium virgatum) biomass from aqueous solution. Experimental parameters affecting biosorption process such as pH, contact time, biomass dosage and temperature were studied. Langmuir, Freundlich and Dubinin-Radushkevich (D-R) models were applied to describe the biosorption isotherms. Langmuir model fitted the equilibrium data better than the Freundlich isotherm. The biosorption capacity of C. virgatum biomass for total chromium was found to be 26.5 mg/g at pH 1.5 and 10 g/L biomass dosage, 90 min equilibrium time and 20 deg. C. From the D-R isotherm model, the mean free energy was calculated as 9.7 kJ/mol, indicating that the biosorption of total chromium was taken place by chemisorption. The calculated thermodynamic parameters ({delta}G{sup o}, {delta}H{sup o}and {delta}S{sup o}) showed that the biosorption of total chromium onto C. virgatum biomass was feasible, ...

2008-12-30

163

Biosorption of Acid Red 274 (AR 274) on Enteromorpha prolifera in a batch system  

Energy Technology Data Exchange (ETDEWEB)

The biosorption of Acid Red 274 (AR 274) dye on Enteromorpha prolifera, a green algae grown on Mersin costs of the Mediterranean, Turkey, was studied as a function of initial pH, temperature, initial dye and biosorbent concentration. The experiments were conducted in a batch manner. The Langmuir and Freundlich isotherms were used for modelling the biosorption equilibrium. At optimum temperature 30 deg C and initial pH 2.0-3.0, the Langmuir isotherm fits best to the experimental equilibrium data with a maximum monolayer coverage of 244 mg/g. The equilibrium AR 274 concentration of the exit stream of a single batch was also obtained by using the experimental equilibrium curve and operating line graphically. The pseudosecond-order kinetic model and Weber-Morris model were applied to the experimental data and it was found that both the surface adsorption as well as intraparticle diffusion contribute to the actual adsorption process. The biosorption ...

2005-11-11

164

Target Diagnostic Instrument-Based Controls Framework for the National Ignition Facility  

Energy Technology Data Exchange (ETDEWEB)

NIF target diagnostics are being developed to observe and measure the extreme physics of targets irradiated by the 192-beam laser. The response time of target materials can be on the order of 100ps--the time it takes light to travel 3 cm--temperatures more than 100 times hotter than the surface of the sun, and pressures that exceed 109 atmospheres. Optical and x-ray diagnostics were developed and fielded to observe and record the results of the first 4-beam experiments at NIF. Hard and soft x-ray spectra were measured, and time-integrated and gated x-ray images of hydrodynamics experiments were recorded. Optical diagnostics recorded backscatter from the target, and VISAR laser velocimetry measurements were taken of laser-shocked target surfaces. Additional diagnostics are being developed and commissioned to observe and diagnose ignition implosions, including various neutron and activation ...

2007-05-07

165

Removal of boron from aqueous solution by using neutralized red mud  

International Nuclear Information System (INIS)

The adsorptive removal of boron from aqueous solution by using the neutralized red mud was studied in batch equilibration technique. The effects of pH, adsorbent dosage, initial boron concentration and contact time on the adsorption were investigated. The experiments demonstrated that boron removal was of a little fluctuation in pH range of 2-7 and it takes 20 min to attain equilibrium. The adsorption data was analyzed using the Langmuir and the Freundlich isotherm models and it was found that the Freundlich isotherm model represented the measured sorption data well.

2007-04-02

166

Adsorption of phosphate from aqueous solution using activated red mud  

Energy Technology Data Exchange (ETDEWEB)

Adsorption of phosphate (PO{sub 4}{sup 3{minus}}) from aqueous solution on activated red mud (ARM) was studied as a function of time, pH, temperature, concentration of adsorbent and adsorbate in acetic acid-sodium acetate buffer medium. The adsorption of phosphate follows Langmuir as well as Freundlich adsorption isotherms. The process efficiency was found to be 80--90% at room temperature. This can be extended to the treatment of industrial effluents containing phosphates like that from phosphatic fertilizer plants.

1998-08-01

167

2D Electrostatic Simulation of the Modulated Electron Beam Interaction with Inhomogeneous Plasma  

International Nuclear Information System (INIS)

Electrostatic plasma simulation code for 2D rectangular geometry is presented. Main distinguishing feature of the code is its orientation on the beam-plasma interaction. The code and its graphical interface were developed using MATLAB programming language. Simulation results of inhomogeneous plasma interaction with modulated electron beams of different width are compared. In case of wide beam the front of Langmuir waves generated in point of local plasma resonance is planar and in case of thin beam (or ribbon beam) the front has approximately half-circular form.

2006-01-01

168

Transmit-receive eddy current probes  

International Nuclear Information System (INIS)

In the last two decades, due to increased inspection demands, eddy current instrumentation has advanced from single-frequency, single-output instruments to multifrequency, computer-aided systems. This has significantly increased the scope of eddy current testing, but, unfortunately, it has also increased the cost and complexity of inspections. In addition, this approach has not always improved defect detectability or signal-to-noise. Most eddy current testing applications are still performed with impedance probes, which have well known limitations. However, recent research at AECL has led to improved eddy current inspections through the design and development of transmit-receive (T/R) probes. T/R eddy current probes, with laterally displaced transmit and receive coils, present a number of advantages over impedance probes. They have improved signal-to-noise ratio in the presence of variable lift-off ...

1997-10-27

169

Experimental studies on a structure of eddy current probe for detection of magnetic flux disturbed by a flaw  

International Nuclear Information System (INIS)

Bobbin-coil-type eddy current probes, which are conventionally used for nondestructive inspection of steam generator tubes in pressurized-water-type nuclear power plants, have poor detectability for circumferential flaws. Hence a new type of eddy current probe was proposed to detect effectively the magnetic flux component disturbed by a flaw and thus to eliminate the flaw direction dependency on the flaw detectability. In the course of development of the proposed method, structures of the probe were investigated based on the measurement of magnetic fields induced by exciting flat coils with several shapes. The new type of probe proposed here consists of differential pick-up coils detecting magnetic flux and exciting coils having a parallelogrammic shape, and its structure was fabricated experimentally in order to detect flaws independently of their directions. Nondestructive flaw detection tests was ...

1995-01-01

170

Understanding the operation and use of high temperature electrochemical corrosion rate probes  

Energy Technology Data Exchange (ETDEWEB)

Electrochemical corrosion rate probes were constructed and tested along with mass loss coupons in a N2/O2/CO2 plus water vapor environment. Temperatures ranged from 450 to 600 C. Corrosion rates for ash-covered mild steel, 304L SS, and 316L SS probes using electrochemical techniques were a function of time, temperature, and process environment. Correlation between electrochemical and mass loss corrosion rates was good.

2004-01-01

171

Finite element prediction of differential eddy current probe signals from Fe _30_4 deposits in PWR steam generators  

International Nuclear Information System (INIS)

The paper is concerned with the simulation of practical testing situations which are too difficult and/or expensive to replicate in a laboratory environment. Numerical experiments are described which simulate the differential eddy current probe response to the build-up and chemical flushing of magnetite in the crevice gap of a PWR steam generator unit. The simulation results agree well with the only experimental data available to the authors and lead to the conclusion that conventional differential eddy current probes should be capable of characterizing crevice gap conditions with respect to the presence of magnetite. (author).

1985-01-01

172

D-brane probe and closed string tachyons  

International Nuclear Information System (INIS)

We consider a D-brane probe in the unstable string background associated with flux branes. The twist in the spacetime metric reponsible for supersymmetry breaking is shown to manifest itself in the mixing of open Wilson lines with the phases of some adjoint matter fields, resulting in a nonlocal and nonsupersymmetric form of Yang-Mills theory as the probe dynamics. This provides a setup where one can study the fate of a large class of unstable closed string theories that includes as a limit type 0 theories and various orbifolds of type II and type 0 theories. We discuss the limit of C/Z_n orbifold in some detail and speculate on the couplings with closed string tachyons.

2002-04-15

173

hh911.cpr  

Science.gov (United States)

"ID# ","Measurement ID Number " "DATE ","Date " "JDATE ","Julian Date " "TIME ", "Local Time " "GMT ","Greenwich Mean Time " "BAND ","Dielectric Probe Band ...

174

X-ray Emission as a Probe of the Wind-Driven Shock in WR 140  

Science.gov (United States)

single star evolution. To understand the evolution of massive stars and their role in shaping the galaxy, understanding of the distribution of ...

175

X-15 Research Results: Chapter 9  

Science.gov (United States)

... hypersonic aerodynamic force, or the space-equivalent region. Some of these experiments change the X-15 from a research airplane to a kind of space probe, ...

177

SQUID Eddy Current Technique Applying Conformable Eddy ...  

Science.gov (United States)

... Accession Number : ADD344580. Title : SQUID Eddy Current Technique Applying Conformable Eddy Current Probes,. Corporate Author : ...

178

SEVEN-YEAR WILKINSON MICROWAVE ANISOTROPY PROBE (WMAP - LAMBDA - NASA  

Science.gov (United States)

of the determinant of the parameter covariance matrix for each ... parameter covariance matrix, as obtained from the Markov chains. The basic set ...

179

Performance Evaluation of Several Types of Pulsed Eddy Current Probes for Detecting Wall Thickness Reduction  

Science.gov (United States)

In this paper, four different types of pulsed eddy current (PEC) probe are designed and their performance of detecting wall thickness reduction is compared. By using the backward difference method in time and the finite element method in space, PEC signals from various thickness and materials are numerically calculated and three features of the signal are selected. Since PEC signals and features are obtained by various types and sizes of probe, the comparison is made through the normalized features which reflect the sensitivity of the feature to thickness reduction. The normalized features indicate that the shielded reflection probe provides the best sensitivity to wall thickness reduction for all three signal features. Results show that the best sensitivity to thickness reduction is achieved by the peak value, but also suggest that the time to peak can be a good candidate because of its linear relationship with the ...

2010-02-01

180

Molecular spectroscopy and planetary atmospheres  

Energy Technology Data Exchange (ETDEWEB)

With the improvements accomplished during the past 15 years in detection techniques and instrumentation and with the opening of space exploration, molecular spectroscopy has become a very efficient way to probe planetary atmospheres.

1984-01-01

181

Improved eddy-current inspection for steam generator tubing  

International Nuclear Information System (INIS)

Computer programs have been written to allow the analysis of different types of eddy-current probes and their performance under different steam generators test conditions. The probe types include the differential bobbin probe, the absolute bobbin probe, the pancake probe and the reflection probe. The generator test conditions include tube supports, copper deposits, magnetite deposits, denting, wastage, pitting, cracking, and intergranular attack. These studies are based mostly on computed values, with the limited number of test specimens available used to verify the computed results. The instrument readings were computed for a complete matrix of the different test conditions, and then the test conditions determined as a function of the readings by a least-squares technique. A comparison was made of the errors in fit and instrument drift for the different ...

1990-03-01

182

Final Report of OT-45, PVM-8, and RVTO Weather ...  

Science.gov (United States)

... A second hydrometeor sampler (MRI Model 1220 ... The cloud particle probe normally installed in ... to the northeast showed no significant movement. ...

1975-07-01

183

Development of a Suite of Luciferase Gene Probes for the ...  

Science.gov (United States)

... between 2 strains is acquired by adding the lengths of the connecting branches, using the scale which depicts 1 amino acid substitution per 10 ...

2011-05-15

184

Development of a FeCoNb Alloy to be used in Eddy Current ...  

Science.gov (United States)

... Accession Number : ADD336001. Title : Development of a FeCoNb Alloy to be used in Eddy Current Probes for Testing Ferromagnetic Tubes,. ...

185

Development of New Ground Inspection Techniques for the ...  

Science.gov (United States)

Integration of Eddy Current probes with MAUS scanning system has been demonstrated to produce scan rates of 36 sqft/hour. System will be designed to ...

186

Deep Space Probe Science Experiment  

Science.gov (United States)

Briefly, 48 MOS microparticle sensors (essentially the same as those flown on .... at the Naval Research Lab to interpret the polarization of the incoming radio .... Adapter Satellite, to be published in Journal of Spacecraft and Rockets, 1994. ...

187

Automated Eddy Current Inspection of Space Shuttle APV ...  

Science.gov (United States)

... perform the inspection in the extremely limited space between adjacent blades and at the blade root, miniature eddy current probes were developed ...

188

Radiation hardening problems of diagnostic components for International Thermonuclear Experimental Reactor (ITER)  

International Nuclear Information System (INIS)

The Joint Work Session of the ITER CDA (Conceptual Design Activities) by four parties, (eg. Japan, USA, USSR and EC), which has continued during 3 years from May 1988 to December 1990 was completed successfully. During the CDA, overall diagnostic systems for the next generation machine was performed for the first time and the principal tasks of Diagnostic research and development (R and D) are identified. In this paper, radiation hardening problems, which should be solved for the period 1991 through 1996 of the ITER EDA (Engineering Design Activities), are described. (author).

189

New developments in the surveillance and diagnostics technology for vibration, structure-borne sound and leakage monitoring systems  

International Nuclear Information System (INIS)

Monitoring and diagnostic systems are of main importance for a safe and efficient operation of nuclear power plants. The author describes new developments with respect to vibration monitoring with a functional extension in the time domain for den secondary circuit, the development of a local system for the surveillance of rotating machines, the structure-borne sound monitoring with improvement of event analysis, esp. the loose part locating, leakage monitoring with a complete system for humidity measurement, and the development of a common platform for all monitoring and diagnostic systems, that allows an efficient access for comparison and cross references.

190

Coherent Synchrotron Radiation as a Diagnostic Tool for the LCLS Longitudinal Feedback System  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL). To ensure the vitality of FEL lasing, a longitudinal feedback system is required together with other diagnostics. In this paper, we study the possibility of using Coherent Synchrotron Radiation (CSR) from the chicane as a diagnostic tool for bunch length feedback. Studies show that CSR is a good candidate, even for a non-Gaussian, double-horn longitudinal charge distribution as in the LCLS. We further check the possibility for detecting possible microbunching.

2005-06-15

191

Cerebral and meningeal manifestations of AIDS: Sensitivity of CT and T sub 2 -weighted MR (129 patients). Zerebrale und meningeale Manifestation des AIDS: Sensitivitaet von CT und T sub 2 -gewichteter MRT (129 Patienten)  

Energy Technology Data Exchange (ETDEWEB)

We studied 129 AIDS patients with suspected or proved intracranial manifestations of the disease. The purpose of this study was to compare the diagnostic sensitivity of unenhanced and contrast enhanced CT and unenhanced T{sub 2}-weighted MR. Thus, in 20% of our patients MR but not CT was diagnostic. In another 20% MR provided additional diagnostic information. In conclusion, MR is recommended as the imaging modality of choice in AIDS patients with non-conclusive cranial CT. (orig./GDG).

1990-09-01

192

A somatic dose index for diagnostic radiology  

International Nuclear Information System (INIS)

Irradiation of the human body in diagnostic X-ray procedures results in different absorbed doses in the various body organs. A somatic dose index in formulated by applying the relative sensitivity of the human to each of the most important somatic effects and utilizing the absorbed dose in the affected organs. This quantity is used to convey a cumulative somatic impact and is computed for common radiographic views in diagnostic radiology as a function of beam quality for a nominal IR entrance exposure. Using typical X-ray beam qualities and exposures, the frequency of the various radiographic views that make up an examination and the frequencies of the various examinations in the national population, illustrative examples of the application of the somatic dose index are presented. (author).

1978-01-01

193

Two-year diagnostic stability in early-onset first-episode psychosis  

British Library Electronic Table of Contents (United Kingdom)

Background:- Only one study has used a prospective method to analyze the diagnostic stability of first psychotic episodes in children and adolescents. The Child and Adolescent First-Episode Psychosis Study (CAFEPS) is a 2-year, prospective longitudinal study of early-onset first episodes of psychosis (EO-FEP). Aim:- To describe diagnostic stability and the variables related to diagnostic changes. Methods:- Participants were 83 patients (aged 9-17-years) with an EO-FEP consecutively attended. They were assessed with a structured interview (Kiddie-Schedule for Affective Disorders and Schizophrenia, Present and Lifetime version) and clinical scales at baseline and after 2-years. Results:- The global consistency for all diagnoses was 63.9%. The small group of bipolar disorder had high stabilit...

2011-01-01

194

Targeting a Ruthenium Complex to the Nucleus with Short Peptides  

UK PubMed Central (United Kingdom)

In an effort to develop octahedral metal complexes as chemotherapeutic and diagnostic agents targeted to DNA, it is critical to optimize the properties of their cellular uptake. Appending d-octaarginine...Full Text Available

2010-05-15

195

Studies on the diagnostic accuracy of lymphography  

International Nuclear Information System (INIS)

Contradictory reports in the literature on the reliability of lymphography stimulated the authors to test the diagnostic accuracy, employing methods which are approximately analogous to practice, using carcinoma of the cervix as the model on which the study was carried out. Using 21 observers it was found that there was no correlation between their experience and on-target accuracy of the diagnosis. Good observers obtained an accuracy of 85% with good proportions between sensitivity in the recognition of detail, specificity and readiness to arrive at a decision on the basis of discriminatory ability. With the help of the concept of the ROC curves, the position taken up by the observers in respect of diagnostic decisions, and a complex manner of assessing the various characteristic factors determining diagnostic accuracy, are demonstrated. This form of test, which permits manipulation of different variants of diagnosis, is ...

196

Reduction of diagnostic expense in space-occupying processes of the pancreas by fine-needle biopsy under computerized tomography (CT)  

International Nuclear Information System (INIS)

Comparative analysis of diagnostic accuracy (dignity determination) in CT-guided fine-needle biopsy (141 patients), CT (141), ultrasonography (89), angiography (50), and cholegraphy (ERCP, 55), was carried out in suspected space-occupying lesions of the pancreas. With accuracy of 86%, sensitivity of 37% and specificity of 92% fine-needle biopsy was superior to imaging procedures. Additional comparison of the results concerning the patients and Roc curves confirm the statements. For reduction of the number of imaging investigations a diagnostic algorithm is proposed, that starts with diagnostic CT and subsequent fine-needle biopsy controlled by CT. This would result in a more adequate use of angiography and ERCP and in the elimination of ultrasonography. (author).

197

Real-Time Diagnostics for a Reusable Rocket Engine - NASA ...  

Science.gov (United States)

of the Intelligent Control System (ICS) for reusable rocket engines. .... the incoming measurements with corresponding estimates, a sensor failure can be ...

198

Radiation risk in computerized tomography (CT)  

Energy Technology Data Exchange (ETDEWEB)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional ...

1984-01-01

199

Radiation risk in computerized tomography (CT)  

International Nuclear Information System (INIS)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional ...

1984-01-01

200

Radiation risk in computerized tomography (CT)  

International Nuclear Information System (INIS)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional ...

201

Pubs.GISS: 1977 Publications  

Science.gov (United States)

Astron. J., 82, 890-901, doi:10.1086/112143. Ghil, M., B. Shkoller, and V. Yangarber, 1977: A balanced diagnostic system compatible with a barotropic prognostic model....

2011-09-17

202

Microscopic-Observation Drug-Susceptibility Assay for the Diagnosis of TB  

UK PubMed Central (United Kingdom)

BACKGROUNDNew diagnostic tools are urgently needed to interrupt the transmission of tuberculosis and multidrug-resistant tuberculosis. Rapid,...Full Text Available

2006-10-12

204

Humoral BMP-2 is Sufficient for Inducing Breast Cancer Microcalcification  

UK PubMed Central (United Kingdom)

Microcalcifications are an important diagnostic marker for breast cancer on mammograms, yet the mechanism of their formation is poorly understood. Indeed, there is presently no short-latency,...Full Text Available

2008-01-01

205

Evaluation of Peripheral Atherosclerosis: A Comparative Analysis of Angiography and Intravascular Ultrasound  

UK PubMed Central (United Kingdom)

ObjectiveAngiography remains a critical component for diagnostic imaging and therapeutic intervention in peripheral arterial disease (PAD). The goal of this study...Full Text Available

2010-04-01

206

Diagnostics of Radionuclides Effects Results  

International Science & Technology Center (ISTC)

Development of New Methods and Means of Assessing of Consequences of Radionuclide and Heavy Metal Salt Effect, Criteria of Forecasting Physiological State and Productivity of the Farm Animals under Conditions of Ecological Pollution of Environment

207

Diagnostic imaging in pregraduate integrated curricula; Radiologie in einem praegraduellen problembasiert-integrierten Medizincurriculum  

Energy Technology Data Exchange (ETDEWEB)

Pregraduate medical curricula are currently undergoing a reform process that is moving away from a traditional discipline-related structure and towards problem-based integrated forms of teaching. Imaging sciences, with their inherently technical advances, are specifically influenced by the effects of paradigm shifts in medical education. The teaching of diagnostic radiology should be based on the definition of three core competencies: in vivo visualization of normal and abnormal morphology and function, diagnostic reasoning, and interventional treatment. On the basis of these goals, adequate teaching methods and e-learning tools should be implemented by focusing on case-based teaching. Teaching materials used in the fields of normal anatomy, pathology, and clinical diagnosis may help diagnostic radiology to play a central role in modern pregraduate curricula. (orig.)

2007-11-15

208

Diagnostic Value of C-reactive Protein in Complicated Appendicitis  

UK PubMed Central (United Kingdom)

PurposeEarly detection of appendicitis has increased due to development of computed tomography and ultrasonography, yet we are frequently meeting complicated appendicitis, including...Full Text Available

2011-06-01

210

Comparison of methods to determine accurate dose calibrator activity measurements  

UK PubMed Central (United Kingdom)

BackgroundIn nuclear medicine, liquid radiopharmaceuticals for diagnostic or therapeutic purposes are administered to patients by using various types of syringes with different volumes....Full Text Available

211

Cardiac Enzymes, Renal Failure and Renal Transplantation  

UK PubMed Central (United Kingdom)

Diagnostic accuracy of the currently available serum markers of cardiac injury, such as myoglobin, creatine kinase and its myocardial isoform, are altered in patients with renal failure. It is shown...Full Text Available

2006-03-01

212

Anxiety and Cancer Treatment: Response to Stressful Radiotherapy  

UK PubMed Central (United Kingdom)

Previous research with individuals undergoing surgery or diagnostic procedures provided a conceptual framework for analysis of radiation therapy, a common form of cancer treatment. The present...Full Text Available

1984-01-01

213

A Dose- and Time-Controllable Syngeneic Animal Model of Breast Cancer Microcalcification  

UK PubMed Central (United Kingdom)

IntroductionThe development of novel diagnostic agents for the detection of breast cancer microcalcifications requires a reliable animal model. Based on previous...Full Text Available

2010-07-01

214

Use of Eu"3"+ as an oxygen environment probe in alkali-alkaline earth-lanthanide phosphates with the #beta#-K_2SO_4 structure  

International Nuclear Information System (INIS)

The use of europium as a local structural probe allows the various phases appearing in the NaCaPO_4-Na_3Eu(PO_4)_2 and NaSrPO_4-Na_3Eu(PO_4)_2 systems to be detected. The broadening of the europium emission lines in going from the calcium to the strontium phases illustrates the ease of displacement of the PO_4 groups. (Auth.).

1983-09-01

215

The fatty acid analogue 11-(dansylamino)undecanoic acid is a fluorescent probe for the bilirubin-binding sites of albumin and not for the high-affinity fatty acid-binding sites.  

UK PubMed Central (United Kingdom)

1. The fluorescent fatty acid probe 11-(dansylamino)undecanoic acid (DAUDA) binds with high affinity to bovine and human serum albumin (BSA and HSA) at three sites. 2. The Kd of the primary binding...Full Text Available

1990-08-15

216

Surface probe measurements in ISX-B and EBT-S  

Energy Technology Data Exchange (ETDEWEB)

Surface deposition probe techniques have been shown to be an effective means of determining the characteristics of the plasma edge region of magnetic confinement devices. Experimental results on ISX-B and EBT-S have led to a consistent picture of the edge plasma and the dominant impurity introduction mechanisms. This picture is supported by numerous other measurements and emphasizes the importance of concentrating several techniques on the complex problems of plasma fusion.

1982-12-01

217

Non-destructive measurement of corrosion effects on high temperature coatings  

Energy Technology Data Exchange (ETDEWEB)

Non-destructive methods for measuring the remaining anticorrosive or antioxidative ability of coatings are investigated. For anticorrosive chromium coatings the increasing ferromagnetism caused by loss of chromium is measured by a permeability probe. Measured values on blades after operation are correlated with the progress of corrosion as determined by metallographic methods. For antioxidative aluminum coatings the diminishing layer thickness is taken as indication for the exhaustion of their protection ability. The layer thickness is measured eddy current probes, especially developed for this application.

1990-01-01

218

Hybridization with synthetic oligonucleotides  

Science.gov (United States)

Procedures are described for the use of synthetic oligonucleotides for Southern blot experiments and gene bank screening, and the effect of various mismatches on the efficiency of hybridization is demonstrated. The following topics are discussed: sensitivity vs. specificity, hybridization of a 12-mer to the lambda endolysin gene; hybridization of oligonucleotide probes to the E. coli lac operator; hybridization of synthetic probes to the CYC1 gene of yeast; and cloning eucaryotic genes. (HLW)

1978-01-01

219

Experimental study on the uses of SQUID magnetometers as sensitive, low-frequency eddy current probes for non-destructive materials evaluation. Final report  

International Nuclear Information System (INIS)

The results show that the SQUID device eddy current testing system is a suitable tool for NDE. Due to the high low-frequency sensitivity of the SQUID sensor, the SQUID device eddy current testing system permits lower examination frequencies than the conventional eddy current probe system. The SQUID system enhances fault detection in even deeper materials layers. (orig./MM).

1996-01-01

220

Eddy current testing of CFRP; New probes and techniques. Wirbelstrompruefung von Kohlefaser-Kompositen; Neue Sonden und Messverfahren  

Energy Technology Data Exchange (ETDEWEB)

Nondestructive inspection of carbon fibre-reinforced plastics (CRFP) using eddy current methods is based not only on the conductivity of the fibres. High frequencies (up to 10 MHz) give access to capacitive effects reflecting properties of the matrix. The paper presents a method using rotating eddy current probes to measure the anisotropic electrical properties. Potential applications of this method are the structural identification of laminates and the estimating of its degradation. (orig.)

1994-01-01

221

Diagnosis of early human myocardial ischemic damage with electron probe microanalysis  

Energy Technology Data Exchange (ETDEWEB)

We determined the Na/K x-ray intensity ratio in frozen sections of myocardial tissues obtained at autopsy from patients who died from various causes, using electron probe analysis. We have been able to distinguish between the ischemically injured and normal cells. The method is simple, fast, and dependable even when the duration of ischemia is only 30 minutes.

1983-03-01

222

Characterization of eddy current probes used in steam generator tubes inspection  

International Nuclear Information System (INIS)

In in-service inspection of steam-generator tubes, the need for reproducibility of the measurement results and for comparison of these results over two successive inspections has led EDF to specify the main characteristics of the eddy-current probes and to design equipment to measure them. This equipment is presented here and the electrical and magnetic results are correlated with those obtained by testing tubes with reference defects.

1985-02-01

223

Characterization of Eddy Current probes used in steam generator tubes inspection  

International Nuclear Information System (INIS)

In in-service inspection of steam-generator tubes, the need for reproducibility of the measurement results and for comparison of these results over two successive inspections has led EDF to specify the main characteristics of the Eddy-Current probes and to design equipment to measure them. This equipment is presented here and the electrical and magnetic results are correlated with those obtained by testing tubes with reference defects. 5 refs.

1985-02-01

224

A study of the eddy-current method of testing the level of molten steel in the thin-slab crystallization process  

British Library Electronic Table of Contents (United Kingdom)

An eddy current probe of the level of molten metal is considered for a sectional machine of continuous casting of steel. The advantages of electromagnetic probes of the level over radiometric ones lie in their insensitivity to the layer of dross and high speed. The results and directions of further studies are given.

2009-01-01

225

Use of DNA probes to study tetracycline resistance determinants in gram-negative bacteria from swine  

Energy Technology Data Exchange (ETDEWEB)

Specific {sup 32}P-labeled DNA probes were prepared and used to evaluate the distribution of tetracycline resistance determinants carried by gram-negative enteric bacteria isolated from pigs in 3 swine herds with different histories of antibiotic exposure. Plasmid DNA, ranging in size from 2.1 to 186 Kb, was observed in over 84% of 114 isolates studied. Two of 78 tetracycline resistant strains did not harbor plasmids. The DNA probes were isolated from plasmids pSL18, pRT29/Tn10, pBR322 and pSL106, respectively, and they represented class A, B, C and D tetracycline resistance determinants. Hybridization conditions using 0.5X SSPE at 65{degrees}C minimize cross-hybridization between the different class of tetracycline resistance genes. Cross-hybridization between class A and class C determinants could be distinguished by simultaneous comparison of the intensity of their hybridization signals. Plasmids from over 44% of the tetracycline resistant ...

1989-01-01

226

Geometrically anisotropic probes: an improved eddy current technique  

Energy Technology Data Exchange (ETDEWEB)

Geometrically anisotropic eddy current probes are a type of separate function probes especially fit to the detection of defects showing a preferential direction. This kind of flaw induces a coupling between the transmitter and the receiver by guiding eddy currents from the one to the other. On the other hand, this coupling will be almost non-existent in the presence of defects or spurious effects not displaying this geometrical particularity. Basic studies on an elementary two-coil set-up allow the acknowledgment of the intrinsic qualities of such probes: good signal-to-noise ratio, influence field practically constant on the whole defect length, ability to detect bridged defects, insensitivity to lift off. These results can be improved by achieving multicoils probes adapted to different kinds of problems. An application to continuous casting slabs testing yields very interesting results in the ...

1987-06-01

227

Evaluation of heterogeneity in thickness of passive films on pure iron by scanning electrochemical microscopy  

Energy Technology Data Exchange (ETDEWEB)

Scanning electrochemical microscopy (SECM) was applied to evaluate the heterogeneity of a passive film formed on a pure iron electrode in deaerated pH 8.4 borate solution. A probe current image of SECM was measured with a tip-generation/sub-strate-collection (TO/SC) mode in deaerated pH 8.4 borate solution containing 0.03 moldm{sup -3} Fe(CN){sub 6}{sup 4-} as a mediator. The difference in thickness of passive films formed on two iron plates at different potentials could be evaluated from the probe current image. The probe current image of the passivated iron surface with distinctive crystal grains was composed of the patch patterns, the shapes of which coincided completely with the shapes of the substrate crystal grains. The probe current flowed above the grain surface oriented to {l_brace}100{r_brace} plane was less than that above the grain surface oriented to {l_brace}110{r_brace} or ...

1999-04-01

228

Trial of using computer tomography in the diagnosis of mediastinal diseases in children  

Energy Technology Data Exchange (ETDEWEB)

In 15 children (in age 2 weeks - 15 years) the computer tomography beside radiological examination was done because of mediastinal diseases. In all cases the computer tomography was valuable. In 4 cases obtained results have changed diagnostic conclusions. The examples are described showing the usefulness of the computer tomography as supplementary diagnostic method in mediastinal diseases in children.

1981-01-01

229

Survey of radiation doses to patients from the diagnostic use of X-rays  

International Nuclear Information System (INIS)

The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).

1977-06-01

230

Spreader Design for FERMI@Elettra Free Electron Laser  

Energy Technology Data Exchange (ETDEWEB)

In this note we describe a conceptual design of a part ofthe electron beam delivery system for FERMI@Elettra free electron laser(FEL) located between the end of the linac and the entrance to the FEL.This part includes the emittance diagnostic section, the electron beamswitchyard for two FELs called spreader and matching sections. The designmeets various constrains imposed by the existing and planned buildingboundaries, desire for utilization of existing equipment and demands forvarious diagnostic instruments.

2007-01-18

231

Researches on gear fault diagnostic techniques  

Science.gov (United States)

Attention is given to recent research on gear fault diagnostic techniques. A mathematic model for vibration signals of defective gears is presented. Novel methods of gear fault diagnosis, such as zoom complex envelope analysis, wideband demodulation techniques, bispectrum analysis, correlation spectrum analysis, and maximum entropy spectrum analysis, are demonstrated. The wide-band demodulation technique is found to exhibit a high SNR. Bispectrum and correlation spectrum are excellent for some mechanical fault forms.

1992-10-01

232

Radiation doses in adults and children in standardized diagnostic radiology  

International Nuclear Information System (INIS)

For comparison of radiation exposure and risk in different diagnostic procedures for adults and children dose measurements and calculations of organs with special risk were carried out. Parameters of image formation influencing image quality as well as of exposure concerning infants and children are recorded and discussed as to radiation exposure and protection. Conclusions are drawn with respect to systems of image formation and to standards of examination and quality assurance.

1987-01-01

233

Process in Plasma Research at IPJ and IPPLM, POLAND  

International Nuclear Information System (INIS)

The most important results of theoretical and experimental studies of plasmas, which have been achieved at the IPJ in Swierk and IPPLM in Warsaw recently, are presented. Studies of physical phenomena in PF discharges, development of diagnostic techniques and research on new plasma technologies, as performed at IPJ, have been summarized. Studies of dense magnetized plasmas, investigation of physics and applications of laser-produced plasmas; and research on the development of advanced diagnostic techniques for the EUROATOM fusion program, as performed at IPPLM, are also described.

2006-01-01

234

Magnetic diagnostic of beta poloidal and internal inductance of plasma in the TCA/BR tokamak  

Energy Technology Data Exchange (ETDEWEB)

This report continues the studies of simplified methods, of magnetic diagnostics in application to TCA/BR tokamak. Here we study the accuracy of known formula for {beta}{sub 1} + l{sub 1}/2 determination from the poloidal magnetic field asymmetry. Errors of the diamagnetic measurements due to vibrations of the vacuum vessel are also considered. (author). 3 refs., 1 fig., 1 tab.

1996-12-31

235

Evaluation of two-beam spectroscopy as a plasma diagnostic  

Energy Technology Data Exchange (ETDEWEB)

A two-beam spectroscopy (TBS) system is evaluated theoretically and experimentally. This new spectroscopic technique uses correlations between components of emitted light separated by a small difference in angle of propagation. It is thus a non-perturbing plasma diagnostic which is shown to provide local (as opposed to line-of-sight averaged) information about fluctuations in the density of light sources within a plasma - information not obtainable by the usual spectroscopic methods. The present design is an improvement on earlier systems proposed in a thesis by Rostler.

1980-04-01

236

Evaluation of Sanofi Diagnostics Pasteur Chlamydia Microplate EIA shortened assay and comparison with cell culture and Syva Chlamydia MicroTrak II EIA in high- and low-risk populations.  

UK PubMed Central (United Kingdom)

Seven hundred thirty-two female urogenital samples were collected for Chlamydia trachomatis testing by both the Sanofi Diagnostics Pasteur (Chaska, Minn.) Chlamydia Microplate EIA by the shortened protocol...Full Text Available

1995-11-01

237

Electron beam and high-speed optical diagnostics for the Los Alamos HIBAF (High Brightness Accelerator FEL) Facility  

Energy Technology Data Exchange (ETDEWEB)

Characterization of the electron beam's properties will be a major task after the upgrade of the Los Alamos Free-Electron Laser (FEL) Facility with a photoelectric injector (PEI) and increased acceleration capability to 40 MeV. Adjustments to the previous diagnostics package that address the lower beam emittance, higher energy, and wakefield source reduction issues will be discussed. 6 refs., 8 figs., 1 tab.

1989-01-01

238

Diagnostic imaging of the acutely injured patient  

Energy Technology Data Exchange (ETDEWEB)

This book provides an analysis of pathophysiologic concepts of trauma and reviews the effectiveness of the available imaging modalities in acute trauma of various organ system. Topics covered are chest injuries; abdominal trauma; fractures of long bones; the foot and ankle; the knee; hand and wrist; the elbow; the shoulder; the pelvis hips; the spine; the skull and facial trauma and the clinical assessment of multiple injuries patients. Comparative evaluation of diagnostic techniques of radiography is discussed. Normal anatomy and bone fractures along with soft-tissue injuries are described.

1985-01-01

239

DIPAC 2005 7. European workshop on beam diagnostics and instrumentation for particle accelerators  

Energy Technology Data Exchange (ETDEWEB)

Accelerators can not be improved without the development of adequate beam instruments and diagnostic tools. This year this statement is particularly right: a lot of contributions are dedicated to beam monitoring and to the design of new beam monitors based on original technologies. This document gathers about 100 contributions.

2005-07-01

240

Computer tomography used in tumour diagnosis in children  

Energy Technology Data Exchange (ETDEWEB)

Computer tomography used in the diagnosis of tumours is described in the light of particularly great diagnostic difficulties in children. Computer tomography was applied in 12 cases. A high diagnostic value of this method was demonstrated, which makes possible a more accurate diagnosis of the position of the tumour, its size, and expanding tendency. The possibility of estimating healthy tissues and organs, and those with pathological changes on the basis of differences in their density with a detection threshold at 0.5% density difference facilitates not infrequently preoperative diagnosis raising the value of the method.

1981-01-01

241

Baryon-strangeness correlations: a diagnostic of stronglyinteracting matter  

Energy Technology Data Exchange (ETDEWEB)

The correlation between baryon number and strangeness elucidates the nature of strongly interacting matter. This diagnostic can be extracted theoretically from lattice QCD calculations and experimentally from event-by-event fluctuations. The analysis of present lattice results above the critical temperature severely limits the presence of q{bar q} bound states, thus supporting a picture of independent (quasi)quarks. Details may be found in [1].

2005-10-07

242

Diagnostic capability of digital radiography of the chest using scanning laser stimulated luminescence  

Energy Technology Data Exchange (ETDEWEB)

Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was evaluated by 19 radiologists, using ROC curve analysis. FCR and ...

1989-02-01

243

Diagnostic capability of digital radiography of the chest using scanning laser stimulated luminescence  

International Nuclear Information System (INIS)

Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was evaluated by 19 radiologists, using ROC curve analysis. FCR and ...

1989-01-01

244

CT-guided percutaneous core biopsies of pulmonary lesions: Diagnostic accuracy, complications and therapeutic impact  

International Nuclear Information System (INIS)

To evaluate the diagnostic accuracy, complications, and therapeutic impact of CT-guided percutaneous core biopsies of pulmonary lesions. Material and methods: Seventy-nine patients underwent diagnostic CT-guided percutaneous core biopsies of pulmonary lesions between July 1995 and March 1999. Evaluation included corresponding clinical data, pathologic results, and therapeutic consequences. Results: There were 29 benign and 50 malignant lesions. Percutaneous core biopsy had an overall diagnostic accuracy of 95%. For malignant lesions, core biopsy was positive in 48 patients (sensitivity 96%), and for benign lesions, in 27 (sensitivity 93%). There were no false-positive findings. Pneumothoraces were observed in 19 patients (24%) and 4 of them required a chest drain (5%). There were no hematothoraces or major bleeding complications; however, postinterventional local hemorrhages were observed in 23 patients (29%). No hemoptysis ...

2001-03-01

245

Transient simulation of a catalytic converter for a dual fuel engine  

Energy Technology Data Exchange (ETDEWEB)

A catalytic converter of a ceramic monolith honeycomb substrate, coated with a washcoat of catalyst and attached to a natural gas/diesel dual fuel engine was simulated and studied experimentally. The paper describes the application of one-dimensional finite element model for the transient and steady state operation. Laminar flow was approximated using a dispersed plug flow model, and chemical kinetics were simulated using LHHW (Langmuir/ Hinshelwood/ Hougan/ Watson) type expressions. Simulation results were compared with experimental results for heating and cooling cycles which resulted from speed and load changes on the engine. The comparison showed a maximum difference between the two sets of emission levels of about 10 per cent, showing that the one-dimensional model is acceptable model for this dual fuel engine converter combination. 50 refs., 3 tabs., 13 figs.

2000-06-01

246

Sorption of Brilliant Red HE-3B Reactive Dye from Aqueous Solution onto Seashells Waste: Equilibrium and Kinetic Studies  

British Library Electronic Table of Contents (United Kingdom)

The potential of waste seashells powder, as a new adsorbent for Brilliant Red HE-3B reactive dye removal from aqueous solutions, was examined by the batch technique. The Freundlich, Langmuir, and Dubinin-Radushkevich adsorption models were applied to describe the equilibrium sorption data and to determine the corresponding isotherm constants. The values of the thermodynamic parameters, ?G, ?H, and ?S, indicate that the sorption of reactive dye is a spontaneous and endothermic process. The kinetic data evaluated by pseudo-first order, pseudo-second order, and intraparticle diffusion kinetic models suggested that the sorption of reactive dye onto seashell is a complex process and both surface sorption and intraparticle diffusion contributes to the rate limiting step.

2011-01-01

247

Sodium gluconate as corrosion and scale inhibitor of ordinary steel in simulated cooling water  

Energy Technology Data Exchange (ETDEWEB)

The effect of sodium gluconate anion (SG) on the corrosion and scale inhibition of ordinary steel in simulated cooling water has been studied using weight loss, polarisation curves, electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM) techniques. SG was studied in concentration from 10{sup -4} M to 10{sup -1} M. Results obtained reveal that SG perform excellently as corrosion and scaling inhibitor for ordinary steel in simulated cooling water. An increase of SG concentration leads to the increase of the corrosion potential towards the positive direction. The inhibition efficiency was a low temperature dependence. The inhibitor mechanism was treated as an adsorption process according to Langmuir adsorption isotherm. The SEM/EDAX data show that was a corrosion and scale inhibitor.

2008-06-15

248

Sodium gluconate as corrosion and scale inhibitor of ordinary steel in simulated cooling water  

British Library Electronic Table of Contents (United Kingdom)

The effect of sodium gluconate anion (SG) on the corrosion and scale inhibition of ordinary steel in simulated cooling water has been studied using weight loss, polarisation curves, electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM) techniques. SG was studied in concentration from 10-4M to 10-1M. Results obtained reveal that SG perform excellently as corrosion and scaling inhibitor for ordinary steel in simulated cooling water. An increase of SG concentration leads to the increase of the corrosion potential towards the positive direction. The inhibition efficiency was a low temperature dependence. The inhibitor mechanism was treated as an adsorption process according to Langmuir adsorption isotherm. The SEM/EDAX data show that was a corrosion and scale inhi...

2008-01-01

249

Self-organization and electrical properties of Head-to-Tail poly(3-hexylthiophene) in Langmuir-Blodgett films  

Energy Technology Data Exchange (ETDEWEB)

The conductive ultra thin films were fabricated from mixed monolayers containing stearic acid and Head-to-Tail poly(3-alkylthiophene). These films exhibited well-defined layered structures as determined by optical absorption and X-ray diffraction measurements. The UV-Vis absorption spectra of these films showed lower energy absorption shifts of 48 nm from that of the random poly(3-alkylthiophene)/stearic acid LB films. The blue shift of absorption maximum of the LB film is attributed to the increase of {pi}-conjugation length caused by no steric hindrance of alkyl side chains. The conductivity of the Head-to-Tail poly(3-hexylthiophene)/stearic acid LB films was greatly improved in the range of 67-100 S/cm. (orig.)

1997-01-01

250

Removal of reactive dye Brilliant Red HE-3B from aqueous solutions by industrial lignin: Equilibrium and kinetics modeling  

British Library Electronic Table of Contents (United Kingdom)

The lignin, one of the main by-products of the pulp industry, can be used to remove dyes from textile wastewaters. The potential of the lignin for Brilliant Red HE-3B reactive dye removal from aqueous solutions at pH=1.5 was examined by the batch technique as a function of dye concentration, solution temperature and contact time. The Freundlich, Langmuir, Dubinin-Radushkevich and Tempkin adsorption isotherms were used to describe the data of sorption equilibrium and to determine its corresponding isotherm constants. The thermodynamic parameters DG, DH and DS were also determined; the obtained values show that the sorption of reactive dye on lignin is a spontaneous, endothermic and entropy-driven process. The kinetic of reactive dye sorption was analyzed using the pseudo-first order and pse...

2010-01-01

251

Kinetics of uranium (VI) ions adsorption on activated charcoal from aqueous solutions  

Energy Technology Data Exchange (ETDEWEB)

The temperature and concentration dependence of the kinetics of uranium(VI) ions adsorption onto activated charcoal from aqueous solutions has been studied. The adsorption proceeds via a rather fast stage followed by a slower one, with activation energies of 5.41 and 17.46 kJ . mol[sup -1] respectively. The diffusion of uranium ions into the pores of the activated charcoal controls the kinetics of adsorption which follows the Langmuir isotherm equation in the concentration range studied. The adsorption equilibrium constant k[sub c] has been derived at temperatures between 283 K and 323 K as well as [Delta] G, [Delta] H and [Delta] S. The results indicate that the adsorption of uranium ions on activated charcoal is an endothermic process. (orig.)

1994-01-01

252

Kinetic and mass transfer analyses of metal biosorption by Caulerpa lentillifera  

British Library Electronic Table of Contents (United Kingdom)

This study examined kinetics and mass transfer in the biosorption of heavy metals onto Caulerpa lentillifera. The sorption capacity of Cu^2^+, Pb^2^+ and Cd^2^+ from aqueous solution increased with initial metal concentration and decreased with biosorbent dose. Kinetic data were well described using the pseudo-second-order model. Results showed that both external mass transfer and intraparticle diffusion were rate limiting steps in the biosorption process. Activation energy of biosorption kinetics fell in the range of 3-13kJ/mol. The biosorption of Cu^2^+, Cd^2^+ and Pb^2^+ on the biomass correlated well with the Langmuir isotherm (R^2>0.99) with maximum sorption capacities at 293K of 0.169, 0.085 and 0.177mol/kg for Cu^2^+, Cd^2^+ and Pb^2^+ ions, respectively. Thermodynamic studies demon...

2011-01-01

253

Gas chromatographic, quentum-chemical, and molecular statistical studies of cluster adsorption of water and methanol molecules on hydrophilic surface sites of hydrophobic adsorbents  

British Library Electronic Table of Contents (United Kingdom)

The comprehensive theoretical and experimental study of the adsorption of water and methanol molecules on active sites (carboxyl and phenol hydroxyl groups) on the graphitized thermal carbon black is performed. It is shown that microclusters formed upon the adsorption of these molecules on such sites are characterized by the cyclic structure comprising 4?5 molecules similar to that whose existence was revealed previously in liquid water and on the surface of silver iodide. The analysis of the studied adsorption clusters demonstrated that the formation of such cycles is governed primarily by the hydrogen bonding; however, a definite role is played also by energy effects associated with the changes in the state of molecular motion during adsorption. It is shown that the generalized Langmuir ...

2008-01-01

254

Desorption of b-carotene from mesoporous carbon coated monolith: Isotherm, kinetics and regeneration studies  

British Library Electronic Table of Contents (United Kingdom)

b-carotene, a natural antioxidant, beneficial form human health prospective. In this study we had examined the recovery of b-carotene form mesoporous carbon coated monolith (MCCM) by batch process. Desorption kinetics and isotherm studies were carried out by using n-hexane as an eluent. Isotherm studies showed better applicability of Langmuir model. The first-order two-compartment three-parameter kinetics model as a function of initial loading concentration and reaction temperature was applied. It was observed that b-carotene desorption process is controlled by both rapid and slow desorption. Results showed that the slow desorption fraction increases from 0.8446 to 0.9007 with increase in initial loading concentration from 10.83 to 39.72mg/g while, the slow desorption fraction decreases fr...

2011-01-01

255

Corrosion inhibition of mild steel by alkylimidazolium ionic liquids in hydrochloric acid  

British Library Electronic Table of Contents (United Kingdom)

The acid corrosion inhibition process of mild steel in 1M HCl by 1-butyl-3-methylimidazolium chlorides (BMIC) and 1-butyl-3-methylimidazolium hydrogen sulfate ([BMIM]HSO4) has been investigated using electrochemical impedance, potentiodynamic polarization and weight loss measurements. Potentiodynamic polarization studies indicate the studied inhibitors are mixed type inhibitors. For both inhibitors, the inhibition efficiency increased with increase in the concentration of the inhibitor and the effectiveness of the two inhibitors are in the order [BMIM]HSO4>BMIC. The adsorption of the inhibitors on mild steel surface obeyed the Langmuirs adsorption isotherm. The effect of temperature on the corrosion behavior in the presence of 5x10-3M of inhibitors was studied in the temperature range of 3...

2009-01-01

256

Competitive adsorption of binary mixture of Leptospirillum ferriphilum and Acidithiobacillus caldus onto pyrite  

British Library Electronic Table of Contents (United Kingdom)

Leptospirillum ferriphilum and Acidithiobacillus caldus are two important acidophilic microorganisms involved in iron and sulfur oxidation during bioleaching. Cell adsorption to mineral surfaces is important for the direct leaching or contact leaching of minerals. In this study, we report the competitive adsorption of binary mixtures of L. ferriphilum LF-104 and A. caldus MTH-04 onto pyrite surfaces. The Langmuir adsorption parameter (CAm) indicated that these two bacteria underwent competitive adsorption to pyrite. Real-time quantitive PCR was used to quantify the relative amounts of L. ferriphilum and A. caldus adsorbed onto the surfaces of pyrite following exposure to a mixture of these two organisms. The adsorption of L. ferriphilum was not affected by A. caldus. However, adsorption of...

2010-01-01

257

Characteristics of diethylenetriamine-crosslinked cotton stalk/wheat stalk and their biosorption capacities for phosphate  

British Library Electronic Table of Contents (United Kingdom)

Two polymeric biosorbents were prepared from cotton stalk (CS) and wheat straw (WS) by the epichlorohydrin-diethylenetriamine-trimethylamine method. Amine-crosslinked cotton stalk (AC-CS) and wheat stalk (AC-WS) were used for the adsorption of phosphate, and their physicochemical properties as well as biosorption properties for phosphate were discussed intensively. Results indicated that the contents of holocellulose in CS and WS corresponded to the distinct phosphate adsorption capacities between AC-CS and AC-WS. Zeta potential and Raman spectra analysis illustrated the electrostatic attraction between phosphate ions and biosorbents. The adsorption of phosphate was not strongly pH dependent when the pH was about 4.0-9.0. The Langmuir isotherm provided the better fit and the maximum adsorp...

2011-01-01

258

Biosorption of lead from aqueous solutions by Bacillus strains possessing heavy-metal resistance  

British Library Electronic Table of Contents (United Kingdom)

In this study, bacterial strains were investigated in order to determine their heavy metal tolerance. The bacterial strains were identified as Bacillus cereus and Bacillus pumilus. In the batch system, the effects of operating variables such as solution pH, initial metal concentration, contact time, and adsorbent dosage were investigated. Both isolates were highly resistance to copper and lead in comparison with the control strain examined. The adsorption capacities of B. cereus and B. pumilus were found to be 22.1mg/g and 28.06mg/g, respectively. The biosorption follows pseudo-second order kinetics and the isotherm fits well to the Langmuir isotherm model. In column experiments, the biosorption was fitted well by the Thomas model. The breakthrough and exhaustion capacity of each biosorben...

2011-01-01

259

Biosorption of Acid Blue 25 by unmodified and CPC-modified biomass of Penicillium YW01: Kinetic study, equilibrium isotherm and FTIR analysis  

British Library Electronic Table of Contents (United Kingdom)

The main objective of this work was to investigate the biosorption performance of unmodified and Cetylpyridinium chloride (CPC)-modified biomass of Penicillium YW 01 for Acid Blue 25 (AB 25). Maximum biosorption capacity of AB 25 onto CPC-modified biosorbent was 118.48mgg^-^1 under phosphoric-phosphate buffer with initial dye concentration of 200mgL^-^1 at 30^oC. The biosorption pattern of AB 25 onto unmodified biosorbent in aqueous solution and phosphoric-phosphate buffer was well fitted with both Langmuir and Freundlich isotherm models. While the equilibrium data of CPC-modified biosorbent in aqueous solution and phosphoric-phosphate buffer failed to fit the Freundlich isotherm model, indicating the monolayer biosorption formed onto CPC-modified biosorbent. The values of initial biosorpt...

2011-01-01

260

Assessment of the adsorption kinetics, equilibrium and thermodynamic for the potential removal of reactive red dye using eggshell biocomposite beads  

British Library Electronic Table of Contents (United Kingdom)

Immobilized eggshell with a polymer mixture of alginate and polyvinyl alcohol was applied as a biocomposite adsorbent (ESC) for the adsorption of C.I. Remazol Reactive Red 198 from aqueous solution. ESC was characterized using XRD, TGA, FTIR and SEM. The Red dye adsorption onto the ESC was investigated in a batch system with respect to initial dye concentration, pH, contact time, agitation speed, solution temperature and biocomposite dosage. The prepared biocomposite exhibits high efficiency for red dye adsorption and the equilibrium states could be achieved in 3h for the different studied initial dye concentrations. The equilibrium isotherm study indicated that sorption data were analyzed and fitted well by both Langmuir and Temkin models compared to Freundlich model. The maximum monolaye...

2011-01-01

261

Adsorption of hexavalent chromium from aqueous solution by using activated red mud  

Energy Technology Data Exchange (ETDEWEB)

Adsorption by activated red mud (ARM) is investigated as a possible alternative to the conventional methods of Cr(VI) removal from aqueous synthetic solutions and industrial effluents. Adsorption characteristics suggest the heterogenous nature of the adsorbent surface sites with respect to the energy of adsorption. Various factors such as pH, contact time, Cr(VI) concentration, amount of adsorbent, and temperature are taken into account, and promising results are obtained. The applicability of the Langmuir as well as Freundlich adsorption isotherms for the present system is tested. The loading factor (i.e., milligrams Cr(VI) adsorbed per gram of ARM) increased with initial Cr(VI) concentration, whereas a negative trend was observed with increasing temperature. The influence of the addition of anions on the adsorption of Cr(VI) depends on the relative affinity of the anions for the surface and the relative concentrations of the anions.

1999-09-01

262

Adsorption of Pb^2^+ and Zn^2^+ from aqueous solutions by sulfured orange peel  

British Library Electronic Table of Contents (United Kingdom)

In this study, sulfured orange peel (MOP) was used as adsorbent to investigate its adsorption behaviors of Pb^2^+ and Zn^2^+ from aqueous solutions. The effects of solution pH, adsorption time and metal ion concentration on adsorption were studied in batch experiments. Both adsorption kinetics of Pb^2^+ and Zn^2^+ proceeded rapidly and could be well described by pesudo-second-order equation. The maximum Langmuir adsorption capacities for Pb^2^+ and Zn^2^+ removal by MOP were evaluated as 164 and 80mg/g, respectively. A binary mixture of Pb^2^+ and Zn^2^+ was studied by using a packed column, suggesting that effective mutual separation and pre-concentration of Pb^2^+ away from Zn^2^+ using MOP could be satisfactory achieved. The results indicate that MOP could be employed as an effective lo...

2011-01-01

263

Adsorption of 1-butanethiol from kerosene oil and red mud  

Energy Technology Data Exchange (ETDEWEB)

Although sulfur is present in many forms in kerosene, mercaptans are most objectionable due to their obnoxious odour and corrosive action. In this study, removal of one of the mercaptans has been reported, using red mud as an unconventional adsorbent. Red mud is a waste product from aluminium producing industries and has been used as an adsorbent for the removal of sulfur compounds as well as for other purposes. Adsorption studies described in this paper indicate that low concentration and high temperature favour the removal of 1-butanethiol from kerosene oil by adsorption on red mud. A first order mechanism has been proposed to describe the adsorption in the present system. Equilibrium data at different temperatures fit well in the Langmuir isotherm equation. Thermodynamic parameters for the present system indicate the feasibility of removal of 1-butanethiol from kerosene oil by adsorption on red mud. 10 refs., 4 figs. 3 tabs.,

1988-06-01

264

Eddy current array probe for detection of surface breaking cracks in the extrados of feeder bends  

Energy Technology Data Exchange (ETDEWEB)

A new eddy current array probe has been implemented as a straightforward and promising technique for detection of outer diameter (OD) surface-breaking cracks on the extrados of feeder bends. The design is based on previous work performed at AECL, which had demonstrated that eddy current probes with laterally displaced transmit-receive coils can overcome some of the limitations of inspecting ferritic steel components for surface-breaking cracks. The Feeder Integrity Joint Program-CANDU Owners Group Inc. (FIJP-COG) Non-Destructive Evaluation (NDE) Team members commissioned AECL to work in collaboration with the probe manufacturer ZETEC, to develop a field usable eddy current array probe. The objective was to acquire a technique with the following capabilities: fast scanning non-contact inspection technique for surface breaking discontinuities; full inspection of the bend extrados OD surface in a single ...

2006-07-01

265

Eddy current array probe for detection of surface breaking cracks in the extrados of feeder bends  

International Nuclear Information System (INIS)

A new eddy current array probe has been implemented as a straightforward and promising technique for detection of outer diameter (OD) surface-breaking cracks on the extrados of feeder bends. The design is based on previous work performed at AECL, which had demonstrated that eddy current probes with laterally displaced transmit-receive coils can overcome some of the limitations of inspecting ferritic steel components for surface-breaking cracks. The Feeder Integrity Joint Program-CANDU Owners Group Inc. (FIJP-COG) Non-Destructive Evaluation (NDE) Team members commissioned AECL to work in collaboration with the probe manufacturer ZETEC, to develop a field usable eddy current array probe. The objective was to acquire a technique with the following capabilities: fast scanning non-contact inspection technique for surface breaking discontinuities; full inspection of the bend extrados OD surface in a single ...

2005-11-20

266

Characterization of axial probes used in eddy current testing; Caracterisation des sondes axiales utilisees en courants de foucault  

Energy Technology Data Exchange (ETDEWEB)

Customized reference tubes reduced sensitivity discrepancies able to be observed from one probe to the other, due to the gain setting adjustment required for a pre-definite level in amplitude response of the artificial notch. The use of a reference circuit in place of a reference part, makes characterization of the probe matched to its generator more accurate: - the material dependence is cancelled during the compensation process, - the reference signal can be adjusted more accurately in amplitude and phase response, - the manufacturing cost is reduced compared to the one necessary for machining the reference part, - the amplitude and phase response of the reference circuit can be simply modelled by using the transformer relations, such as one can appreciate the variations of the probe definition parameters and its connexion to the generator, and makes them optimal for use. The method proposed by ALSTOM for the ...

2001-07-01

267

Sequential injection system for phospholipase A2 activity evaluation: Studies on liposomes using an environment-sensitive fluorescent probe  

British Library Electronic Table of Contents (United Kingdom)

This work reports the development of an automatic methodology based on the use of 1-anilinonaphthalene-8-sulfonate (ANS) as an interfacial fluorescent probe for detecting the hydrophobic environment shift around the probe, caused by the hydrolytic action of PLA2 on the liposomes. The implementation of this reaction in a sequential injection analysis (SIA) system along with the use of the mixing chambers permitted the evaluation of PLA2 activity and assessment of the inhibitory effect of the non-steroidal anti-inflammatory drugs (NSAIDs) on PLA2 activity. Several studies were performed with the aim of establishing the appropriate flow system configuration: the liposome substrate; PLA2 and ANS optimum concentrations and incubation times before and after the enzyme addition. Based on these st...

2009-01-01

268

Probing anomalous quartic couplings in e{gamma} and {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We analyze the potential of the e{sup +}e{sup -} linear colliders, operating in the e{gamma} and {gamma}{gamma} modes, to probe anomalous quartic vector-boson interactions through the multiple production of W's and Z's. We examine all SU(2){sub L}(circle times)U(1){sub Y} chiral operators of order p{sup 4} that lead to new four-gauge-boson interactions but do not alter trilinear vertices. We show that the e{gamma} and {gamma}{gamma} modes are able not only to establish the existence of a strongly interacting symmetry breaking sector but also to probe for anomalous quartic couplings of the order of 10{sup -2} at 90% C.L. Moreover, the information gathered in the e{gamma} mode can be used to reduce the ambiguities of the e{sup +}e{sup -} mode.

2001-10-01

269

Probing anomalous quartic couplings in e#gamma# and #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We analyze the potential of the e"+e"- linear colliders, operating in the e#gamma# and #gamma##gamma# modes, to probe anomalous quartic vector-boson interactions through the multiple production of W's and Z's. We examine all SU(2)_L(circle times)U(1)_Y chiral operators of order p"4 that lead to new four-gauge-boson interactions but do not alter trilinear vertices. We show that the e#gamma# and #gamma##gamma# modes are able not only to establish the existence of a strongly interacting symmetry breaking sector but also to probe for anomalous quartic couplings of the order of 10"-"2 at 90% C.L. Moreover, the information gathered in the e#gamma# mode can be used to reduce the ambiguities of the e"+e"- mode.

2001-10-01

270

Microtiter plate assay for phosphate using a europium-tetracycline complex as a sensitive luminescent probe  

Energy Technology Data Exchange (ETDEWEB)

A new luminescent europium probe is presented for the determination of phosphate (P) in microtiter plate format. The assay is based on the quenching of the luminescence of the europium-tetracycline (EuTc) 1:1 complex by phosphate using a reagent concentration of 20.8 {mu}mol/L. The probe is excited at 400 nm and displays a large Stokes' shift of 210 nm. The emission maximum is located at 616 nm. The system works best at neutral pH 7 and is therefore suitable for phosphate determination in biological and biochemical systems. The linear range of the calibration plot is from 5 x 10{sup -6} mol/L to 7.5 x 10{sup -4} mol/L of phosphate, and the limit of detection is 3 {mu}mol/L.

2006-01-12

271

Extra-dimensional gravity and dijet production at {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

In this Brief Report, we consider dijet production at {gamma}{gamma} colliders as a probe of recently proposed, large extra-dimensional gravity models. The exchange of virtual, spin-2 graviton towers (Kaluza-Klein excitations) significantly modifies the cross section, as compared to the standard model predictions. We find that, in order to maximize the value of the effective scale that can be probed at a given center-of-mass energy, a very severe p{sub T} cut should be applied; in general, a p{sub T} equal to approximately 46% of the e{sup +}e{sup -} beam energy gives the highest reach. We find that we can probe the effective mass scale from about 2.7 TeV to 11.1 TeV, depending on the center-of-mass energy and assumptions about the model. (c) 2000 The American Physical Society.

2000-06-01

272

Extra-dimensional gravity and dijet production at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

In this Brief Report, we consider dijet production at #gamma##gamma# colliders as a probe of recently proposed, large extra-dimensional gravity models. The exchange of virtual, spin-2 graviton towers (Kaluza-Klein excitations) significantly modifies the cross section, as compared to the standard model predictions. We find that, in order to maximize the value of the effective scale that can be probed at a given center-of-mass energy, a very severe p_T cut should be applied; in general, a p_T equal to approximately 46% of the e"+e"- beam energy gives the highest reach. We find that we can probe the effective mass scale from about 2.7 TeV to 11.1 TeV, depending on the center-of-mass energy and assumptions about the model. (c) 2000 The American Physical Society

2000-06-01

273

Eddy current probe development based on a magnetic sensor array; Developpement d'un imageur magnetique pour le controle non destructif par courants de Foucault  

Energy Technology Data Exchange (ETDEWEB)

This research deals with in the study of the use of innovating magnetic sensors in eddy current non destructive inspection. The author reports an analysis survey of magnetic sensor performances. This survey enables the selection of magnetic sensor technologies used in non destructive inspection. He presents the state-of-the-art of eddy current probes exploiting the qualities of innovating magnetic sensors, and describes the methods enabling the use of these magnetic sensors in non destructive testing. Two main applications of innovating magnetic sensors are identified: the detection of very small defects by means of magneto-resistive sensors, and the detection of deep defects by means of giant magneto-impedances. Based on the use of modelling, optimization, signal processing tools, probes are manufactured for these both applications.

2007-06-15

274

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

International Nuclear Information System (INIS)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-22

275

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

Energy Technology Data Exchange (ETDEWEB)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-01

276

Utilization of fermentation waste (Corynebacterium glutamicum) for biosorption of Reactive Black 5 from aqueous solution  

Energy Technology Data Exchange (ETDEWEB)

A fermentation waste, Corynebacterium glutamicum, was successfully employed as a biosorbent for Reactive Black 5 (RB5) from aqueous solution. This paper initially studied the effect of pretreatment on the biosorption capacity of C. glutamicum toward RB5, using several chemical agents, such as HCl, H{sub 2}SO{sub 4}, HNO{sub 3}, NaOH, Na{sub 2}CO{sub 3}, CaCl{sub 2} and NaCl. Among these reagents, 0.1 M HNO{sub 3} gave the maximum enhancement of the RB5 uptake, exhibiting 195 mg/g at pH 1 with an initial RB5 concentration of 500 mg/l. The solution pH and temperature were found to affect the biosorption capacity, and the biosorption isotherms derived at different pHs and temperatures revealed that a low pH (pH 1) and high temperature (35 deg. C) favored biosorption. The biosorption isotherm was well represented using three-parameter models (Redlich-Peterson and Sips) compared to two-parameter models (Langmuir and Freundlich models). As a result, high correlation ...

2007-03-06

277

Trivalent chromium removal from wastewater using low cost activated carbon derived from agricultural waste material and activated carbon fabric cloth  

International Nuclear Information System (INIS)

An efficient adsorption process is developed for the decontamination of trivalent chromium from tannery effluents. A low cost activated carbon (ATFAC) was prepared from coconut shell fibers (an agricultural waste), characterized and utilized for Cr(III) removal from water/wastewater. A commercially available activated carbon fabric cloth (ACF) was also studied for comparative evaluation. All the equilibrium and kinetic studies were conducted at different temperatures, particle size, pHs, and adsorbent doses in batch mode. The Langmuir and Freundlich isotherm models were applied. The Langmuir model best fit the equilibrium isotherm data. The maximum adsorption capacities of ATFAC and ACF at 25 deg. C are 12.2 and 39.56 mg/g, respectively. Cr(III) adsorption increased with an increase in temperature (10 deg. C: ATFAC-10.97 mg/g, ACF-36.05 mg/g; 40 deg. C: ATFAC-16.10 mg/g, ACF-40.29 mg/g). The kinetic studies were conducted to delineate the ...

2006-07-31

278

Removal of basic dye by modified Unye bentonite, Turkey  

Energy Technology Data Exchange (ETDEWEB)

The adsorption behavior of crystal violet (CV{sup +}) from aqueous solution onto raw (RB) and manganese oxide-modified (MMB) bentonite samples was investigated as a function of parameters such as initial CV{sup +} concentration, contact time and temperature. The Langmuir, Freundlich and Dubinin-Radushkevich (D-R) adsorption models were applied to describe the equilibrium isotherms. The Langmuir monolayer adsorption capacities of RB and MMB were estimated as 0.32 and 1.12 mmol/g, respectively. The mean adsorption energy derived from D-R isotherm for MMB showed that the type of adsorption of dye molecules on this material may be defined as chemical adsorption. The adsorption rate was fast and more than half of the adsorbed-CV{sup +} was removed in the first 55 min for RB and 5 min for MMB at the room temperature. The pseudo-first-order, pseudo-second-order kinetic and the intraparticle diffusion models were used to describe the kinetic data and ...

2009-03-15

279

Kinetic and thermodynamic studies of the biosorption of Cr(VI) by Pinus sylvestris Linn  

Energy Technology Data Exchange (ETDEWEB)

Biosorption equilibrium, kinetics and thermodynamics of chromium(VI) ions onto cone biomass were studied in a batch system with respect to temperature and initial metal ion concentration. The biosorption efficiency of chromium ions to the cone biomass decreased as the initial concentration of metal ions was increased. But cone biomass of Pinus sylvestris Linn. exhibited the highest Cr(VI) uptake capacity at 45 {sup o}C. The biosorption efficiency increased from 67% to 84% with an increase in temperature from 25 to 45 deg. C at an initial Cr(VI) concentration of 300 mg/L. The Langmuir isotherm model was applied to experimental equilibrium data of Cr(VI) biosorption depending on temperature. According to Langmuir isotherm, the monolayer saturation capacity (Q{sub max}) is 238.10 mg/g. The pseudo-first-order and pseudo-second-order kinetic models were applied to test the experimental data for initial Cr(VI). The pseudo-second-order kinetic model ...

2008-05-01

280

Equilibrium, kinetic and thermodynamic study of the biosorption of uranium onto Cystoseria indica algae  

Energy Technology Data Exchange (ETDEWEB)

Biosorption equilibrium, kinetics and thermodynamics of binding of uranium ions to Cystoseria indica were studied in a batch system with respect to temperature and initial metal ion concentration. Algae biomass exhibited the highest uranium uptake capacity at 15 deg. C at an initial uranium ion concentration of 500 mg l{sup -1} and an initial pH of 4. Biosorption capacity increased from 198 to 233 mg g{sup -1} with an decrease in temperature from 45 to 15 deg. C at this initial uranium concentration. The Langmuir isotherm model were applied to experimental equilibrium data of uranium biosorption depending on temperature. Equilibrium data fitted very well to the Langmuir model C. indica algae in the studied concentration range of Uranium ions at all the temperatures studied. The saturation type kinetic model was applied to experimental data at different temperatures changing from 15 to 45 deg. C to describe the batch biosorption kinetics ...

2008-02-11

281

Biosorption of Pb(II) and Cd(II) from aqueous solution using green alga (Ulva lactuca) biomass  

Energy Technology Data Exchange (ETDEWEB)

The biosorption characteristics of Pb(II) and Cd(II) ions from aqueous solution using the green alga (Ulva lactuca) biomass were investigated as a function of pH, biomass dosage, contact time, and temperature. Langmuir, Freundlich and Dubinin-Radushkevich (D-R) models were applied to describe the biosorption isotherm of the metal ions by U. lactuca biomass. Langmuir model fitted the equilibrium data better than the Freundlich isotherm. The monolayer biosorption capacity of U. lactuca biomass for Pb(II) and Cd(II) ions was found to be 34.7 mg/g and 29.2 mg/g, respectively. From the D-R isotherm model, the mean free energy was calculated as 10.4 kJ/mol for Pb(II) biosorption and 9.6 kJ/mol for Cd(II) biosorption, indicating that the biosorption of both metal ions was taken place by chemisorption. The calculated thermodynamic parameters ({delta}G{sup o}, {delta}H{sup o} and {delta}S{sup o}) showed that the biosorption of Pb(II) and Cd(II) ions ...

2008-03-21

282

The electron cyclotron absorption diagnostic for the JET pumped divertor plasma  

International Nuclear Information System (INIS)

We present the design of a diagnostic system to measure electron cyclotron absorption at the second harmonic E-mode resonance in the JET pumped divertor plasma. The diagnostic will measure transmission as a function of frequency along one or more sightlines from which the spatial profile of the n_eT_e product will be deduced. The divertor is briefly described, and the electron cyclotron resonance physics relevant to this measurement is reviewed. The problems of measuring transmission using an oversized transmission system are discussed and the chosen measurement technique, a swept frequency interferometer using a coherent radiation source, is described. A prototype of the instrument has been assembled to test the measurement technique. Some data demonstrating the instrument's characteristics are presented. The nonresonant losses, which may affect the interpretation of the measurement, are also discussed. (orig.).

1993-03-01

283

Neutron imaging system for neutron tomography, radiography, and beam diagnostics  

Energy Technology Data Exchange (ETDEWEB)

A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.

1995-12-31

284

Wavelength-Dependent Differential Interference Contrast Microscopy: Selectively Imaging Nanoparticle Probes in Live Cells  

Energy Technology Data Exchange (ETDEWEB)

Gold and silver nanoparticles display extraordinarily large apparent refractive indices near their plasmon resonance (PR) wavelengths. These nanoparticles show good contrast in a narrow spectral band but are poorly resolved at other wavelengths in differential interference contrast (DIC) microscopy. The wavelength dependence of DIC contrast of gold/silver nanoparticles is interpreted in terms of Mie's theory and DIC working principles. We further exploit this wavelength dependence by modifying a DIC microscope to enable simultaneous imaging at two wavelengths. We demonstrate that gold/silver nanoparticles immobilized on the same glass slides through hybridization can be differentiated and imaged separately. High-contrast, video-rate images of living cells can be recorded both with and without illuminating the gold nanoparticle probes, providing definitive probe identification. Dual-wavelength DIC microscopy thus presents a new approach ...

2009-11-15

285

Validating eddy current array probes for inspecting steam generator tubes  

International Nuclear Information System (INIS)

A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques and procedures. Methods are presented for calculating POD curves ...

1997-11-16

286

Validating eddy current array probes for inspecting steam generator tubes  

Energy Technology Data Exchange (ETDEWEB)

A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques and procedures. Methods are presented for calculating POD curves ...

1997-07-01

287

Transversal Stiffness and Young's Modulus of Single Fibers from Rat Soleus Muscle Probed by Atomic Force Microscopy  

UK PubMed Central (United Kingdom)

AbstractThe structural integrity of striated muscle is determined by extra-sarcomere cytoskeleton that includes structures that connect the Z-disks and M-bands of a sarcomere to sarcomeres...Full Text Available

2010-02-03

288

The efflux of a fluorescent probe is catalyzed by an ATP-driven extrusion system in Lactococcus lactis.  

UK PubMed Central (United Kingdom)

Many bacteria, both gram positive and gram negative, extrude in an energy-dependent manner the fluorescent pH indicator 2',7'-bis-(2-carboxyethyl)-5[and -6]-carboxyfluorescein (BCECF) (D. Molenaar,...Full Text Available

1992-05-01

289

The direct comparison of health and ulcerated stomach tissue: A multiple probe microdialysis sampling approach  

UK PubMed Central (United Kingdom)

The ability to directly compare gastric ulcerated and healthy tissue would aid in the understanding of the physiological differences between these tissue types. Presently, these comparisons...Full Text Available

2008-09-10

290

Strategies for the uses of lanthanide NMR shift probes in the determination of protein structure in solutio. Application to the EF calcium binding site of carp parvalbumin.  

UK PubMed Central (United Kingdom)

The homologous sequences observed for many calcium binding proteins such as parvalbumin, troponin C, the myosin light chains, and calmodulin has lead to the hypothesis that these proteins have homologous...Full Text Available

1980-10-01

291

Rapid technique of DNA-DNA in situ hybridisation on formalin fixed tissue sections using microwave irradiation.  

UK PubMed Central (United Kingdom)

The relative sensitivities of different protocols for detecting cytomegalovirus nucleic acid sequences in histological specimens, using a biotinylated cDNA probe, were assessed. Several commonly used...Full Text Available

1987-08-01

293

Probing the structural hierarchy and energy landscape of an RNA T-loop hairpin  

UK PubMed Central (United Kingdom)

The T-loop motif is an important recurrent RNA structural building block consisting of a U-turn sub-motif and a UA trans Watson–Crick/Hoogsteen base pair. In the presence of...Full Text Available

2007-11-01

294

Probing the Mechanisms of an Air Amplifier using a LTQ-FT-ICR-MS and Fluorescence Spectroscopy  

UK PubMed Central (United Kingdom)

We report the first quantitative assessment of electrosprayed droplet/ion focusing enabled by the use of a voltage-assisted air amplifier between an electrospray ionization emitter and a hybrid...Full Text Available

2007-11-01

295

Probing active galactic nuclei with H2O megamasers.  

UK PubMed Central (United Kingdom)

We describe the characteristics of the rapidly rotating molecular disk in the nucleus of the mildly active galaxy NGC4258. The morphology and kinematics of the disk are delineated by the point-like...Full Text Available

1995-12-05

296

Probing a Membrane Matrix Regulating Hormone Action  

UK PubMed Central (United Kingdom)

Auxin-induced pea (Pisum sativum) stem section elongation is enhanced at levels of 3 to 40 micromolar by six new classes of alkane derivatives additional to those described earlier,...Full Text Available

1971-11-01

297

Probing Compulsive and Impulsive Behaviors, from Animal Models to Endophenotypes: A Narrative Review  

UK PubMed Central (United Kingdom)

Failures in cortical control of fronto-striatal neural circuits may underpin impulsive and compulsive acts. In this narrative review, we explore these behaviors from the perspective of neural processes...Full Text Available

2010-02-01

298

Pressure Probe Technique for Measuring Water Relations of Cells in Higher Plants 1  

UK PubMed Central (United Kingdom)

A new method is described for continuously measuring cell turgor pressure (P), hydraulic conductivity (Lp), and volumetric elastic modulus (ε) in higher plant cells, using a pressure...Full Text Available

1978-02-01

299

Osmotically Induced Removal of Water from Fungal Cells as Determined by a Spin Probe Technique 1  

UK PubMed Central (United Kingdom)

Effects of physical environment on plasma membrane semipermeability and osmotic induction of changes in aqueous cytoplasmic volume were studied in vegetative and spore cells of a plant pathogenic fungus,...Full Text Available

1978-11-01

300

New Biomarkers Probing Depth of Cell Senescence Assessed by Laser Scanning Cytometry  

UK PubMed Central (United Kingdom)

The imaging analytical capabilities of laser scanning cytometer (LSC) have been used to assess morphological features considered to be typical of the senescent phenotype. The characteristic “flattening”...Full Text Available

2010-11-01

301

Near Infrared Dyes as Lifetime Solvatochromic Probes for Micropolarity Measurements of Biological Systems  

UK PubMed Central (United Kingdom)

The polarity of biological mediums controls a host of physiological processes such as digestion, signaling, transportation, metabolism, and excretion. With the recent widespread use of near-infrared...Full Text Available

2007-10-15

302

Multiple-element eddy current probes for enhanced inspection  

Energy Technology Data Exchange (ETDEWEB)

Eddy current inspection methods are widely used for the nondestructive evaluation (NDE) of tubular products. Specifically, the sensors and instrumentation are designed to detect and characterize changes in a material's electrical and magnetic properties produced by the presence of discontinuities. A recent major enhancement in eddy current inspection technology has been the development of computer interfacing for data collection, analysis, and display. This breakthrough has led to multiple-frequency testing, eddy current imaging, and automated data interpretation systems that significantly enhance both capabilities and reliability of the eddy current inspection. In addition to the clear advantages in data processing, computer interfacing also permits the design and creation of unique sensors that further enhance eddy current inspection capabilities. Perhaps the most promising area of computer interactive probe design is multiple element sensors. ...

1993-07-01

303

Mercury modeling for PWSCC length sizing. [Primary water stress corrosion cracking  

Science.gov (United States)

This report describes the results of EPRI Program S404-28, titled Experimental Modeling of Eddy Current Response'', conducted by the Westinghouse Science and Technology Center (STC). The Westinghouse STC demonstrates that its mercury modeling technique provides an unique bridge between steam generator eddy current field inspection conditions and predictions obtained using recently developed analytical models. The mercury modeling technique was used systematically to explore factors which contribute to primary water stress corrosion cracking (PWSCC) sizing inaccuracy, including probe design, coil excitation frequency, crack length, and crack morphology. Two new proposed techniques for inverting crack lengths from eddy current data are compared with the technique commonly used in field data analysis for PWSCC. The performance of uniform field eddy current probes is compared with the performance of pancake coil ...

1992-08-01

304

Mercury modeling for PWSCC length sizing. [Primary water stress corrosion cracking  

Energy Technology Data Exchange (ETDEWEB)

This report describes the results of EPRI Program S404-28, titled Experimental Modeling of Eddy Current Response'', conducted by the Westinghouse Science and Technology Center (STC). The Westinghouse STC demonstrates that its mercury modeling technique provides an unique bridge between steam generator eddy current field inspection conditions and predictions obtained using recently developed analytical models. The mercury modeling technique was used systematically to explore factors which contribute to primary water stress corrosion cracking (PWSCC) sizing inaccuracy, including probe design, coil excitation frequency, crack length, and crack morphology. Two new proposed techniques for inverting crack lengths from eddy current data are compared with the technique commonly used in field data analysis for PWSCC. The performance of uniform field eddy current probes is compared with the performance of pancake coil ...

1992-08-01

305

Localization of gold in synovial membrane of rheumatoid arthritis treated with sodium aurothiomalate. Studies by electron microscope and electron probe x-ray microanalysis.  

UK PubMed Central (United Kingdom)

The localization of gold in the synovial membrane of rheumatoid arthritis patients treated with sodium aurothiomalate was examined and quantitative analysis of epon-embedded sections was carried out...Full Text Available

1977-06-01

306

Ion clustering in aqueous solutions probed with vibrational energy transfer  

UK PubMed Central (United Kingdom)

Despite prolonged scientific efforts to unravel the hydration structures of ions in water, many open questions remain, in particular concerning the existences and structures of ion clusters in 1∶1...Full Text Available

2011-03-22

307

Investigation of the hadronic final state in electron-proton interactions at HERA  

Energy Technology Data Exchange (ETDEWEB)

The main subject of this thesis is the study of the hardronic final state in deep-inelastic electron-proton scattering. Theexperiment described in this thesis is performed with such a high resolution that the substructure of the proton is probed by the electron beam with a resolution of less than 10{sup -15} cm. (orig./HSI).

1995-09-18

308

Inspection of PFR steam generators  

International Nuclear Information System (INIS)

The inspection of PFR evaporator tubing, superheater and reheater tubing, and tube plate examinations, are described. Ferritic steel U tubes in the evaporator have been examined by an eddy current system operating at 400 kHz using flexible rotating probes. Surface defects as shallow as 0.1 mm can be detected and sized in the range 0.1 to 0.5 mm deep. An ultrasonic method is under development for wall thickness. Special test coil probes have been developed for examination of the type 316 stainless steel superheater and reheater tubing. Crack-life defects in the bore are detectable at approximately 10% wall thickness and 20% on the outside diameter. Tube plate examinations from the tube holes, have been conducted using eddy current probes which identify surface breaking cracks in the holes. For detecting curtain cracks between tube plate holes, ultrasonic compression wave probes have been used. (U.K.).

1976-03-09

309

In-Space Propulsion Program Advanced Sensor Project - NASA  

Science.gov (United States)

Aug 25, 2004 ... Current Developments in Future Planetary Probe Sensors: .... Data: Outgoing and incoming EIA RS-422 interface for serial data transmission (for electrical purposes only, .... Milos, et. al, Journal of Spacecraft & Rockets 1999 ...

310

In-Situ Atr Ftir Probe Investigation of Selective Organic Synthetic Routes Using Nanoscale Crystal Reactors  

Environmental Research Database

ObjectivesThe overall aim of this work is to use an in-situ FTIR probe to investigate selected heterogeneous catalysts in industrially relevant organic reactions. This approach will be broadly applicable to the UK fine chemical manufacturing base.~%~~%~The project has the following specific objectives:~%~~%~- To demonstrate and develop the use of an in-situ FTIR probe in a batch reactor at elevated temperatures (eg greater than 100 deg C) to monitor reactant usage and product formation.~%~~%~- To validat [continued...]DescriptionThis proposal concerns the in-situ study of catalytic processes and reaction kinetics. The catalysts concerned are microporous materials, such as, zeolites, containing pores and cavities of molecular dimensions. These catalysts constitute crystal reactors on a nanometer scale that are selective on a size and shape basis for organic molecules used in this ...

2003-01-31

311

In service inspection for steam generator tubes  

International Nuclear Information System (INIS)

In this paper the authors show the means putting in place for examination of steam generators tubes. These means (eddy current probes, ultrasonic testing) associated with a knowledge on degradation phenomena allow mapping controlled tubes and limiting undesirable obturations.

1987-11-24

312

High speed optical coherence microscopy with autofocus adjustment and a miniaturized endoscopic imaging probe  

UK PubMed Central (United Kingdom)

Optical coherence microscopy (OCM) is a promising technique or high resolution cellular imaging in human tissues. An OCM system for high-speed en face cellular resolution imaging...Full Text Available

2010-03-01

313

Functional pools of oxidative and glycolytic fibers in human muscle observed by 31P magnetic resonance spectroscopy during exercise.  

UK PubMed Central (United Kingdom)

Quantitative probing of heterogeneous regions in muscle is feasible with phosphorus-31 magnetic resonance spectroscopy because of the differentiation of metabolic patterns of glycolytic and oxidative...Full Text Available

1987-12-01

314

Fluorine-19 NMR Chemical Shift Probes Molecular Binding to Lipid Membranes  

UK PubMed Central (United Kingdom)

The binding of amphiphilic molecules to lipid bilayers is followed by 19F NMR using chemical shift and line shape differences between the solution and membrane-tethered states of...Full Text Available

2008-05-22

315

Five-Year Wilkinson Microwave Anisotropy Probe (WMAP1 - LAMBDA - NASA  

Science.gov (United States)

If we decompose C1 using SVD the parameter covariance matrix can be inverted to ... However, we can analyze the parameter covariance matrix directly by ...

316

Fatigue crack detection in aircraft skin structures using eddy current array technique  

International Nuclear Information System (INIS)

Detection of fatigue damage cracks in aircraft skin structures is an ongoing NDT challenge. Cracks growing rate is difficult to predict, and for this reason, it is important to detect them as soon as possible to avoid a catastrophic break. Eddy current methods are known and well-accepted techniques which are relatively simple to carry out. However, with conventional inspection of airframe structures using standard driver-pickup eddy current probes, it is difficult to detect small fatigue cracks initiated in the second layer of the skin and in the shadow region at fastener holes. Such difficulty is related to fasteners length and their spacing which reduces test sensitivity. This report explains the development of improved eddy current probe/technique to detect and visualize fatigue cracks in fasteners. In this study, an eddy current array probe was evaluated and new coil design was suggested. Several tests were conducted on ...

2004-01-01

317

Evaluation of 13C isotopic tracers for metabolic flux analysis in mammalian cells  

UK PubMed Central (United Kingdom)

13C metabolic flux analysis (MFA) is the most comprehensive means of characterizing cellular metabolic states. Uniquely labeled isotopic tracers enable more focused analyses to probe...Full Text Available

2009-11-01

318

Enhanced defect detection and sizing accuracy using matrix phased array ultrasonic tools  

Energy Technology Data Exchange (ETDEWEB)

Although ultrasonic testing inspection technology and tools have improved significantly, there is still a need for more reliable detection, monitoring, and accurate sizing of crack-like and planar defects, complex corrosion damage, and detection of secondary features within deformed pipe. Ultrasonic two dimensional (2D) matrix phased array technology offers some unique advantages that make the technology promising for improving detection and sizing of pipeline flaws resulting from welding or from in-service damage. Ultrasonic modeling and simulation has been conducted to evaluate the detection and sizing capabilities of 2D matrix arrays for various pipeline inspection concepts. Simulations have been performed using both flexible and rigid array probes. Inspection concepts using rigid probes were evaluated for inspections from both the outside and inside pipe surfaces, while flexible probes were evaluated primarily for ...

2009-07-01

319

Dissociation dynamics of methylal  

Energy Technology Data Exchange (ETDEWEB)

The dissociation of methylal is investigated using mass spectrometry, combined with a pyrolytic radical source and femtosecond pump probe experiments. Based on preliminary results two reaction paths of methylal dissociation are proposed and discussed. (author) 4 fig., 3 refs.

1999-08-01

320

Development of compression-controlled low-level laser probe system: towards clinical application  

UK PubMed Central (United Kingdom)

Various physico-chemical tissue optical clearing (TOC) methods have been suggested to maximize photon density in tissue. In order to enhance photon density, a compression-controlled low-level...Full Text Available

2010-09-01

321

Detecting variants with Metabolic Design, a new software tool to design probes for explorative functional DNA microarray development  

UK PubMed Central (United Kingdom)

BackgroundMicroorganisms display vast diversity, and each one has its own set of genes, cell components and metabolic reactions. To assess their huge unexploited metabolic potential...Full Text Available

322

Design of 240,000 orthogonal 25mer DNA barcode probes  

UK PubMed Central (United Kingdom)

DNA barcodes linked to genetic features greatly facilitate screening these features in pooled formats using microarray hybridization, and new tools are needed to design large sets of barcodes to allow...Full Text Available

2009-02-17

323

Design and Construction of a Versatile Dual Volume Heteronuclear Double Resonance Microcoil NMR Probe  

UK PubMed Central (United Kingdom)

Improved NMR detection of mass limited samples can be obtained by taking advantage of the mass sensitivity of microcoil NMR, while throughput issues can be addressed using multiple, parallel...Full Text Available

2009-04-01

324

Comparative analysis of nitrifying bacteria associated with freshwater and marine aquaria.  

UK PubMed Central (United Kingdom)

Three nucleic acid probes, two for autotrophic ammonia-oxidizing bacteria of the beta subdivision of the class Proteobacteria and one for alpha subdivision nitrite-oxidizing bacteria, were developed...Full Text Available

1996-08-01

325

Biotin-labeled hairpin oligonucleotides: probes to detect double-strand breaks in DNA in apoptotic cells.  

UK PubMed Central (United Kingdom)

Hairpin oligonucleotides were synthesized with stems ending in a double-stranded structure, which can be ligated to double-strand breaks in DNA, and with loops that contain nucleotides modified by the...Full Text Available

1998-04-01

326

Application of automatic inspection system to nondestructive test of heat transfer tubes of primary pressurized water cooler in the high temperature engineering test reactor. Joint research  

International Nuclear Information System (INIS)

Heat transfer tubes of a primary pressurized water cooled (PPWC) in the high temperature engineering test reactor (HTTR) form the reactor pressure boundary of the primary coolant, therefore are important from the viewpoint of safety. To establish inspection techniques for the heat transfer tubes of the PPWC, an automatic inspection system was developed. The system employs a bobbin coil probe, a rotating probe for eddy current testing (ECT) and a rotating probe for ultrasonic testing (UT). Nondestructive test of a half of the heat transfer tubes of the PPWC was carried out by the automatic inspection system during reactor shutdown period of the HTTR (about 55% in the maximum reactor power in this paper). The nondestructive test results showed that the maximum signal-to-noise ratio was 1.8 in ECT. Pattern and phase of Lissajous wave, which were obtained for the heat transfer tube of the PPWC, were different from those ...

327

An investigation of the distribution of resistivity in single crystal germanium ribbon by the single probe method  

CERN Document Server

Experimental data are reported on the micro-irregularities of resistivity in longitudinal and transverse specimens of germanium 0.5 to 0.8 mm in thickness and 25 to 40 mm in width. These data are correlated with the conditions of growth of the crystals. (16 refs).

1972-01-01

328

AeroSpace Information for a Changing World - NASA Technical ...  

Science.gov (United States)

Probing Neutron Star Evolution with Gamma Rays Online Source: Click to View PDF File [PDF Size: 217 KB] Author: Wijers, Ralph A. M. J. ...

329

A novel fluorescent pH probe for expression in plants  

UK PubMed Central (United Kingdom)

BackgroundThe pH is an important parameter controlling many metabolic and signalling pathways in living cells. Recombinant fluorescent pH indicators (pHluorins) have come into vogue...Full Text Available

330

A Meta-Analysis of Animal Studies on Disruption of Spatial Navigation by Prenatal Cocaine Exposure  

UK PubMed Central (United Kingdom)

Water-maze testing has been used to assess prenatal cocaine (PCOC)- induced deficits in behavioral studies of spatial navigation and memory abilities. Effects of PCOC in acquisition or in probe...Full Text Available

2007-01-01

331

Wilson loops in warped resolved deformed conifolds  

CERN Document Server

We calculate quark-antiquark potentials using the relationship between the expectation value of the Wilson loop and the action of a probe string in the string dual. We review and categorize the possible forms of the dependence of the energy on the separation between the quarks. In particular, we examine the possibility of there being a minimum separation for probe strings which do not penetrate close to the origin of the bulk space, and derive a condition which determines whether this is the case. We then apply these considerations to the flavoured resolved deformed conifold background of Gaillard et al. We suggest that the unusual behaviour we observe in this solution is likely to be related to the IR singularity which is not present in the unflavoured case.

2011-01-01

332

Use of Eu/sup 3 +/ as an oxygen environment probe in alkali-alkaline earth-lanthanide phosphates with the. beta. -K/sub 2/SO/sub 4/ structure  

Energy Technology Data Exchange (ETDEWEB)

The use of europium as a local structural probe allows the various phases appearing in the NaCaPO/sub 4/-Na/sub 3/Eu(PO/sub 4/)/sub 2/ and NaSrPO/sub 4/-Na/sub 3/Eu(PO/sub 4/)/sub 2/ systems to be detected. The broadening of the europium emission lines in going from the calcium to the strontium phases illustrates the ease of displacement of the PO/sub 4/ groups.

1983-09-15

333

The enteral probe nutrition with Cosilat in complex therapy of patients with radiotherapeutic late effects of the colon  

International Nuclear Information System (INIS)

Results are presented applying an enteral nutrition by means of probes with Cosilat in complex therapy of patients with radiotherapeutic late effects of the colon. This nutrition was prescribed with the intention to gave the colon a functional recovery and to guarantee optimal conditions for repair of radiation injuries. Good results were seen in 27 of 28 patients (96.7%), the situation of one patient (3.3%) continued without any change. Cosilat has a high nutritive value, good organoleptic qualities and is well digested without any complications. (author).

334

Principal geological results of petroleum and gas prospecting on Southern Sakhalin  

Energy Technology Data Exchange (ETDEWEB)

Results are given for deep-level petroleum and gas drilling probes in various coastal zones of Southern Sakhalin covering the Poronai depression and the Aniv Bay trough. The exploratory probes indicate that the Middle Miocence deposits of the Boundary trough contain commercial-size deposits of petroleum, that commercial-size gas deposits are in the upper Myocene deposits of the Aliv Bay trough, and that the upper Cretaceous and Cenozoic deposits of the eastern section of Southern Sakhalin lack folded deformations. 7 references, 2 figures.

1981-01-01

335

Local secondary-electron emission spectra of graphite and gold surfaces obtained using the Scanning Probe Energy Loss Spectrometer (SPELS)  

International Nuclear Information System (INIS)

Secondary-electron emission (SEE) spectra have been obtained with the Scanning Probe Energy Loss Spectrometer at a tip-sample distance of only 50 nm. Such short working distances are required for the best theoretical spatial resolution (<10 nm). The SEE spectra of graphite, obtained as a function of tip bias voltage, are shown to correspond to unoccupied states in the electronic band structure. The SEE spectra of thin gold films demonstrate the capability of identifying (carbonaceous) surface contamination with this technique.

2009-11-25

336

Deterministic loading of individual atoms to a high-finesse optical cavity  

CERN Document Server

Individual laser cooled atoms are delivered on demand from a single atom magneto-optic trap to a high-finesse optical cavity using an atom conveyor. Strong coupling of the atom with the cavity field allows simultaneous cooling and detection of individual atoms for time scales exceeding 15 s. The single atom scatter rate is studied as a function of probe-cavity detuning and probe Rabi frequency, and the experimental results are in good agreement with theoretical predictions. We demonstrate the ability to manipulate the position of a single atom relative to the cavity mode with excellent control and reproducibility.

2007-01-01

337

Detection of EDM defects under Monju support plate using experimental data from remote field eddy current probes and a multi-frequency algorithm  

International Nuclear Information System (INIS)

This paper describes detection of electro-discharged machine (EDM) defects in magnetic steam generator (SG) tubes of Monju fast breeder reactor (FBR). The EDM defects are located under support plate (SP), on the outer tube surface and they are detected by a remote field eddy current probe. Using the experimental measurements and a multi frequency algorithm, the defect signal can be extracted from the SP signal. The parameters of the multi-frequency algorithm were calculated by comparing SP measurements with two-dimensional finite element simulations (FEM). (author)

2006-07-01

338

APSIS - an Artificial Planetary System in Space to probe extra-dimensional gravity and MOND  

CERN Document Server

A proposal is made to test Newton's inverse-square law using the perihelion shift of test masses (planets) in free fall within a spacecraft located at the Earth-Sun L2 point. Such an Artificial Planetary System In Space (APSIS) will operate in a drag-free environment with controlled experimental conditions and minimal interference from terrestrial sources of contamination. We demonstrate that such a space experiment can probe the presence of a "hidden" fifth dimension on the scale of a micron, if the perihelion shift of a "planet" can be measured to sub-arc-second accuracy. Some suggestions for spacecraft design are made.

2006-01-01

339

A truly commercial product  

International Nuclear Information System (INIS)

In one of the first uses of high Tc superconductors in an end-use product, Lake Shore Cryotronics and a Swiss lab have developed a liquid nitrogen level sensor using a high Tc thin film. The probe is manufactured using a seamless stainless steel tube with an yttrium-based zirconium oxide flame-sprayed on the tube. A plasma-sprayed superconductor compound is deposited on top of that. The probe is coated with a sealant that protects the superconducting film from the atmosphere. This manufacturing method has yielded an extremely durable product. Unaffected by ice formation and related mechanical problems, the superconducting level sensor can be kept in the dewar for long periods of time.

340

$B \\to X_{s} \\gamma$ and $B \\to X_{s} l^{+} l^{-}$ decays at LHCb  

CERN Document Server

\\lhcb is one of the four major experiments at the Large Hadron Collider (\\lhc) at CERN. It is custom built to look for CP violation and New Physics in rare decays of heavy flavour hadrons, like the B and D systems. Rare decays that occur via loop diagrams provide a way to probe New Physics at energy scales much higher than can be probed by direct production in experiments. In this article, the \\lhcb prospects for such measurements with exclusive decays of the type $B \\to \\Xs \\gamma$ and $B \\to X_{s} l^{+} l^{-}$ are presented.

2011-01-01

341

$B \\to X_s\\gamma$ and $B\\to X_sl^+l^-$ decays at LHCb  

CERN Document Server

LHC$b$ is one the four major experiments at the Large Hadron Collider (LHC) at CERN. It is custom built to look for CP violation and New Physics in rare decays of heavy flavor hadrons, like the B and D systems. Rare decays that occur via loop diagrams provide a way to probe New Physics at energy scales much higher than can be probed by direct production in experiment. In this article, the LHC$b$ prospects for such measurement with exclusive decays of the type $B \\to X_s\\gamma$ and $B\\to X_sl^+l^-$ are presented.

2011-01-01

342

Traumatic extremity arterial injury in children: Epidemiology, diagnostics, treatment and prognostic value of Mangled Extremity Severity Score  

UK PubMed Central (United Kingdom)

BackgroundTraumatic paediatric arterial injuries are a great challenge due to low incidence and specific characteristics of paediatric anatomy and physiology. The aim of the present...Full Text Available

343

The treatment of mycosis fungoides and related conditions with particular emphasis on electron therapy.  

UK PubMed Central (United Kingdom)

The difficulties created by the lack of generally accepted views on classification, diagnostic criteria and natural history of the cutaneous lymphomata are discussed. Only the lymphomata which remain...Full Text Available

1975-03-01

344

The sensitivity of real-time PCR amplification targeting invasive Salmonella serovars in biological specimens  

UK PubMed Central (United Kingdom)

BackgroundPCR amplification for the detection of pathogens in biological material is generally considered a rapid and informative diagnostic technique. Invasive Salmonella...Full Text Available

345

The concept of mental disorder: diagnostic implications of the harmful dysfunction analysis  

UK PubMed Central (United Kingdom)

What do we mean when we say that a mental condition is a medical disorder rather than a normal form of human suffering or a problem in living? The status of psychiatry as a medical discipline depends...Full Text Available

2007-10-01

346

The Effect of Age on the Gingival Crevicular Fluid Composition During Experimental Gingivitis. A Pilot Study  

UK PubMed Central (United Kingdom)

Background:Cytokines have been proposed as potentially useful diagnostic or prognostic markers of periodontal inflammation related alterations during the experimental gingivitis...Full Text Available

347

Stereocomplexed PLA-PEG Nanoparticles with Dual-Emissive Boron Dyes for Tumor Accumulation  

UK PubMed Central (United Kingdom)

Responsive biomaterials play important roles in imaging, diagnostics, and therapeutics. Polymeric nanoparticles (NPs) containing hydrophobic and hydrophilic segments are one class of biomaterial...Full Text Available

2010-09-28

348

Stability of Trichomonas vaginalis DNA in Urine Specimens?  

UK PubMed Central (United Kingdom)

Trichomonas vaginalis is an important pathogen in both men and women. Culture is considered the diagnostic gold standard, although studies have shown that PCR is more sensitive than...Full Text Available

2008-05-01

349

Serum hepcidin as a diagnostic test of iron deficiency in premenopausal female blood donors  

UK PubMed Central (United Kingdom)

BackgroundCurrently used indicators of iron status have limitations. Hepcidin, a key regulator of iron metabolism, is reduced in iron deficiency. We sought to determine the properties...Full Text Available

2011-08-01

350

Rome III: The functional gastrointestinal disorders, third edition, 2006  

UK PubMed Central (United Kingdom)

Functional gastrointestinal disorders (FGIDs) represent a common and important class of disorders within gastroenterology. RomeI, the first edition was published in 1994, with symptom-based diagnostic...Full Text Available

2008-04-07

351

Reduced PCR Sensitivity Due to Impaired DNA Recovery with the MagNA Pure LC Total Nucleic Acid Isolation Kit  

UK PubMed Central (United Kingdom)

The increasing demand for molecular diagnostics in clinical microbiology laboratories necessitates automated sample processing. In the present study, we evaluated the performance of the MagNA Pure LC...Full Text Available

2005-09-01

352

Real-time system for processing regime diagnostic on accelerator  

International Nuclear Information System (INIS)

The automatic real-time system operating at the LU-10 linac and providing measurements of the parameters such as the beam current (average and pulse values), the electron energy, the linear density distribution of beam current, and also the conveyor speed is described in the paper.

353

Pubs.GISS: Ghil et al. 1977: A balanced ... - Publications - NASA  

Science.gov (United States)

Ghil, M., B. Shkoller, and V. Yangarber, 1977: A balanced diagnostic system compatible with a barotropic prognostic model. M. Weather. Rev. , 105, 1223- 1238, ...

354

Prenatal diagnosis for recessive dystrophic epidermolysis bullosa in 10 families by mutation and haplotype analysis in the type VII collagen gene (COL7A1).  

UK PubMed Central (United Kingdom)

BACKGROUND: Epidermolysis bullosa (EB) is a group of heritable diseases that manifest as blistering and erosions of the skin and mucous membranes. In the dystrophic forms of EB (DEB), the diagnostic...Full Text Available

1996-01-01

355

Performance and usefulness of the Hexagon rapid diagnostic test in children with asymptomatic malaria living in the Mount Cameroon region  

UK PubMed Central (United Kingdom)

BackgroundRapid and correct diagnosis of malaria is considered an important strategy in the control of the disease. However, it remains to be determined how well these tests can...Full Text Available

356

PROGRESS AND PROBLEMS IN THE APPLICATION OF FOCUSED ULTRASOUND FOR BLOOD-BRAIN BARRIER DISRUPTION  

UK PubMed Central (United Kingdom)

Advances in neuroscience have resulted in the development of new diagnostic and therapeutic agents for potential use in the central nervous system (CNS). However, the ability to deliver the...Full Text Available

2008-08-01

357

Optical and Structural Characteristics of Heavily Boron-Implanted CdTe.  

Science.gov (United States)

Cadmium telluride single crystals were subjected to multiple-energy boron ion implants with total doses up to 1.5 x 10 sq cm. Various diagnostic techniques were used to assess the structural and electronic properties of these crystals in their as-implante...

1988-01-01

358

Nuclear ? catenin as a potential prognostic and diagnostic marker in patients with colorectal cancer from Hong Kong  

UK PubMed Central (United Kingdom)

Aims: To study the expression of nuclear β catenin in patients with colorectal cancer, colorectal adenoma, and colorectal polyps to elucidate its role in carcinogenesis, and its...Full Text Available

2003-12-01

359

Multiplexed, rapid detection of H5N1 using a PCR-free nanoparticle-based genomic microarray assay  

UK PubMed Central (United Kingdom)

BackgroundFor more than a decade there has been increasing interest in the use of nanotechnology and microarray platforms for diagnostic applications. In this report, we describe...Full Text Available

360

Monitoring potential neurotoxic effects of hazardous waste disposal  

UK PubMed Central (United Kingdom)

This report reviews neurotoxicological principles relevant to situations of hazardous waste disposal. Some of the diagnostic techniques currently used for field assessment of nervous system dysfunction...Full Text Available

1983-02-01

361

Investigation of Dyslexia and SLI Risk Variants in Reading- and Language-Impaired Subjects  

UK PubMed Central (United Kingdom)

Dyslexia (or reading disability) and specific language impairment (or SLI) are common childhood disorders that show considerable co-morbidity and diagnostic overlaps and have been suggested to share...Full Text Available

2011-01-01

362

Impalpable Testis and Laparoscopy: When the Gonad Is Not Visualized  

UK PubMed Central (United Kingdom)

The diagnostic accuracy of laparoscopy for impalpable testis is well recognized. However, in some cases, laparoscopic findings may be misleading, and a viable gonad may be missed with significant medico-legal...Full Text Available

2004-01-01

363

Impact of radiation measurements on hardening of TFTR diagnostics  

International Nuclear Information System (INIS)

Contrary to previous plans for the preparation of diagnostic systems for D-T break-even experiments in the Tokamak Fusion Test Reactor (TFTR), it now appears that a limited Q#approx#1 demonstration can be carried out without constructing a close-fitting igloo radiation shield around the tokamak. In order to assess the impact of D-T operation of TFTR without an igloo shield, particularly with regard to hardening of diagonstic systems, we have mapped neutron and gamma fluxes inside the test cell and test cell basement, using a variety of radiation measurements. The measurements are sufficiently detailed to resolve massive hardware components, such as neutral beams and shielded diagnostic systems, and can be used to predict local fluxes. By comparing the measurements with transport code calculations for the case of a bare tokamak, we conclude that the models have substantially overestimated fluxes both inside and outside the TFTR shield walls. It ...

364

Identification of Cardiac Myosin-binding Protein C as a Candidate Biomarker of Myocardial Infarction by Proteomics Analysis*  

UK PubMed Central (United Kingdom)

Acute myocardial infarction (AMI) is a common cause of death for which effective treatments are available provided that diagnosis is rapid. The current diagnostic gold standards are circulating cardiac...Full Text Available

2009-12-01

365

IGENPRO knowledge-based digital system for process transient diagnostics and management  

Energy Technology Data Exchange (ETDEWEB)

Verification and validation issues have been perceived as important factors in the large scale deployment of knowledge-based digital systems for plant transient diagnostics and management. Research and development (R&D) is being performed on the IGENPRO package to resolve knowledge base issues. The IGENPRO approach is to structure the knowledge bases on generic thermal-hydraulic (T-H) first principles and not use the conventional event-basis structure. This allows for generic comprehensive knowledge, relatively small knowledge bases and above all the possibility of T-H system/plant independence. To demonstrate concept feasibility the knowledge structure has been implemented in the diagnostic module PRODIAG. Promising laboratory testing results have been obtained using data from the full scope Braidwood PWR operator training simulator. This knowledge structure is now being implemented in the transient management module PROMANA to treat ...

1997-12-31

366

How Missing Information in Diagnosis Can Lead to Disparities in the Clinical Encounter  

UK PubMed Central (United Kingdom)

Previous studies have documented diagnostic bias and noted that its reduction could eliminate misdiagnosis and improve mental health service delivery. Few studies have investigated clinicians'...Full Text Available

2008-11-01

367

Gonorrhoea in men: clinical and diagnostic aspects.  

UK PubMed Central (United Kingdom)

AIM: To review the features of gonococcal infection in men in the 1990s. METHODS: A retrospective study of all men with gonorrhoea presenting to an inner city department of genitourinary medicine in...Full Text Available

1996-12-01

368

Genetic screening: The vista of genomic medicine  

UK PubMed Central (United Kingdom)

The accelerating development of biochemical and DNA-based diagnostic tests for human genetic conditions in the last decade has engendered a revolution in genetic diagnosis. Both genetic testing and...Full Text Available

2011-01-01

369

Gamuts in nuclear medicine  

Energy Technology Data Exchange (ETDEWEB)

This book provides differential diagnostic possibilities of specific scan abnormalities in one volume for easy reference. This book is organized by organ systems and covers the central nervous system, the endocrine, skeletal, pulmonary, gastrointestinal, genitourinary, and cardiovascular systems. The gamuts are designed to teach differential diagnosis and to assist in the actual interpretation of patient slides.

1983-01-01

370

Fetal, perinatal, and infant death with congenital renal anomaly  

UK PubMed Central (United Kingdom)

Aims: To ascertain why 19.6% of pregnancies in which a fetal renal anomaly has been detected fail to produce a surviving child, and whether antenatal diagnostic accuracy has altered since...Full Text Available

2002-08-01

371

Fetal ascites: an unusual presentation of Niemann-Pick disease type C.  

UK PubMed Central (United Kingdom)

Two infants were seen with severe ascites detected before birth, a previously unreported presentation of Niemann-Pick disease type C. In the second infant no diagnostic storage cells were present in...Full Text Available

1989-10-01

372

Evaluation of the OptiMAL Test for Rapid Diagnosis of Plasmodium vivax and Plasmodium falciparum Malaria  

UK PubMed Central (United Kingdom)

The development of rapid and specific diagnostic tests to identify individuals infected with malaria is of paramount importance in efforts to control the severe public health impact of this disease....Full Text Available

1998-01-01

373

Evaluation of a diagnostic algorithm for heart disease in neonates.  

UK PubMed Central (United Kingdom)

OBJECTIVE--To develop, test, and validate an algorithm for diagnosing disease in neonates during an over the telephone referral to a specialist cardiac centre. DESIGN--A draft algorithm requiring only...Full Text Available

1991-04-20

374

Diagnostics of Gun Barrel Propellants.  

Science.gov (United States)

Page 1. Page 2. Page 3. Page 4. Page 5. Page 6. Page 7. Page 8. Page 9. Page 10. Page 11. Page 12. Page 13. Page 14. Page 15. Page 16. Page ...

1983-11-01

375

Diagnostic quality of low resolution images for tele-woundcare.  

UK PubMed Central (United Kingdom)

The use of digital wound images would allow remote consultation between patients, physicians, or other caregivers over the Internet. To evaluate the efficacy and validity of digital images for assessment...Full Text Available

1998-01-01

376

Diagnostic Dilemma in an Unusual Case of Common Bile Duct Obstruction  

UK PubMed Central (United Kingdom)

Biliary obstructions are rarely caused by a foreign body and have received sparse attention. We present an unusual case with pruritis and abdominal pain caused by impacted full length surgical gauze...Full Text Available

2011-06-01

377

Development and Application of Pathovar-Specific Monoclonal Antibodies That Recognize the Lipopolysaccharide O Antigen and the Type IV Fimbriae of Xanthomonas hyacinthi  

UK PubMed Central (United Kingdom)

The objective of this study was to develop a specific immunological diagnostic assay for yellow disease in hyacinths, using monoclonal antibodies (MAbs). Mice were immunized with a crude cell wall preparation...Full Text Available

1999-09-01

378

Decreased CSF Transferrin in sCJD: A Potential Pre-Mortem Diagnostic Test for Prion Disorders  

UK PubMed Central (United Kingdom)

Sporadic Creutzfeldt-Jakob-disease (sCJD) is a fatal neurodegenerative condition that escapes detection until autopsy. Recently, brain iron dyshomeostasis accompanied by increased transferrin (Tf) was...Full Text Available

379

Cystic neoplasms of the pancreas: A diagnostic challenge  

UK PubMed Central (United Kingdom)

Cystic neoplasms of the pancreas are increasingly recognized due to the expanding use and improved sensitivity of cross-sectional abdominal imaging. Major advances in the last decade have led to an...Full Text Available

2009-01-07

380

Comparing the Diagnostic Performance of 2 Clinical Decision Rules to Rule Out Deep Vein Thrombosis in Primary Care Patients  

UK PubMed Central (United Kingdom)

PURPOSE The Wells rule is widely used for clinical assessment of patients with suspected deep vein thrombosis (DVT), especially in the secondary care setting. Recently a new clinical decision...Full Text Available

2011-01-01

381

Colonic polyps: inheritance, susceptibility, risk evaluation, and diagnostic management  

UK PubMed Central (United Kingdom)

Colorectal cancer (CRC) is the third-ranked neoplasm in order of incidence and mortality, worldwide, and the second cause of cancer death in industrialized countries. One of the most important environmental...Full Text Available

382

Clinical value of SPECT/CT for evaluation of patients with painful knees after total knee arthroplasty- a new dimension of diagnostics?  

UK PubMed Central (United Kingdom)

BackgroundThe purpose of our study was to evaluate the clinical value of hybrid SPECT/CT for the assessment of patients with painful total knee arthroplasty (TKA).MethodsTwenty-three...Full Text Available

383

Clinical efficacy of the use of information technology in cardiology: initial results of angiographic teleconsultation in the Netherlands  

UK PubMed Central (United Kingdom)

Background With the increasing use of cineless diagnostic angiography laboratories, modern telecommunication networks provide an excellent opportunity to transfer dynamic cardiac...Full Text Available

2001-12-01

384

Characteristics of common solid liver lesions and recommendations for diagnostic workup  

UK PubMed Central (United Kingdom)

Due to the widespread clinical use of imaging modalities such as ultrasonography, computed tomography and magnetic resonance imaging (MRI), previously unsuspected liver masses are increasingly being...Full Text Available

2009-07-14

385

CT versus MRI in the study of the articular diseases of the knee  

International Nuclear Information System (INIS)

The authors present a comparison between the diagnostic accuracy of Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) in the articular pathologies of the knee. CT and MRI were performed in 30 patients who subsequently underwent surgery. CT and MRI results were compared on three bases: technique, definition of normal anatomy, and diagnostic accuracy. CT allowed a standardization of the technique, while MRI was superior in defining normal anatomy - especially in the study of capsulo-ligamentous structures. In all cases the use of both CT and MRI allowed a correct diagnosis, showing the site, extent and gravity of the lesion. CT proved to be superior to MRI in 4 cases, while MRI corrected CT diagnosis in 11 cases; in 15 patients both techniques had the same diagnostic accuracy. Meniscal tears were better identified by CT, while MRI was superior in the detection of ligamentous lesions and in the characterization of ...

1988-01-01

386

CT evaulation of thoracic and abdominal fatty masses  

International Nuclear Information System (INIS)

The diagnostic accuracy of computed tomography (CT) in several patterns of thoracic and abdominal fatty masses, has been examined. In selected cases our findings overlap the features of the recent literature. The possibility of surgical therapy in peculiar cases of adipose deposits, commonly esteemed benign, is considered.

1986-01-01

387

Blood conservation strategies to reduce the need for red blood cell transfusion in critically ill patients  

UK PubMed Central (United Kingdom)

Anemia commonly affects critically ill patients. The causes are multifactorial and include acute blood loss, blood loss from diagnostic testing and blunted red blood cell production. Blood transfusions...Full Text Available

2008-01-01

388

Bilateral Pneumothorax and Subcutaneous Emphysema following Endoscopic Retrograde Cholangiopancreatography: A Rare Complication  

UK PubMed Central (United Kingdom)

Endoscopic Retrograde Cholangiopancreatography (ERCP) is a widely used diagnostic and therapeutic modality in the management of biliary and pancreatic disease. Some of the complications of the procedure,...Full Text Available

2010-01-01

389

Anti-albumin antibodies in chronic liver diseases: diagnostic significance of these antibodies in patients with conventional or immunosuppressive therapy.  

UK PubMed Central (United Kingdom)

The two categories of anti-albumin antibodies (AAA), namely precipitins (AA-P) and agglutinins (AA-Aggl), were investigated in 260 patients with morphologically diagnosed chronic liver diseases (CLD)....Full Text Available

1981-02-01

390

An evaluation of cerebrospinal fluid oligoclonal banding confirmed by immunofixation on agarose gel.  

UK PubMed Central (United Kingdom)

The cerebrospinal fluid (CSF) from 115 consecutive patients undergoing diagnostic lumbar puncture or myelography was examined to determine the usefulness of immunofixation, following agarose gel electrophoresis,...Full Text Available

1983-06-01

391

Affinity maturation of human botulinum neurotoxin antibodies by light chain shuffling via yeast mating  

UK PubMed Central (United Kingdom)

Botulism is caused by the botulinum neurotoxins (BoNTs), the most poisonous substance known. Because of the high potency of BoNT, development of diagnostic and therapeutic antibodies for botulism requires...Full Text Available

2010-04-01

392

Advances in cancer tissue microarray technology: Towards improved understanding and diagnostics  

UK PubMed Central (United Kingdom)

Over the past few years, tissue microarray (TMA) technology has been established as a standard method for assessing the expression of proteins or genes across large sets of tissue specimens....Full Text Available

2006-03-30

393

Advances in Fine Needle Aspiration Cytology for the Diagnosis of Pulmonary Carcinoma  

UK PubMed Central (United Kingdom)

New developments in the field of thoracic oncology have challenged the way pathologists approach the diagnosis of pulmonary carcinoma. Nonsmall cell carcinoma is no longer an adequate diagnostic category....Full Text Available

394

Accuracy of electrocardiographic and echocardiographic indices in predicting life threatening ventricular arrhythmias in patients operated for tetralogy of Fallot  

UK PubMed Central (United Kingdom)

OBJECTIVE—To validate the accuracy of the prognostic significance of non-invasive clinical diagnostic indices as predictors of sustained ventricular tachycardia (sVT) or fibrillation...Full Text Available

1999-06-01

395

A survey on clinical presentation and nutritional status of infants with suspected cow' milk allergy  

UK PubMed Central (United Kingdom)

BackgroundCow's milk is the most common food allergen in infants and the diagnosis of cow's milk allergy is difficult, even with the use of several diagnostic tests. Therefore, elimination...Full Text Available

396

A diagnostic survey of infants referred for chromosome analysis in the neonatal period.  

UK PubMed Central (United Kingdom)

Examination and assessment of 140 liveborn and stillborn infants referred within two weeks of birth for chromosome analysis showed that 48 had Down's syndrome, 12 other chromosome abnormalities, 17...Full Text Available

1980-10-18

397

Synopsis of moisture monitoring by neutron probe in the unsaturated zone at Area G  

Energy Technology Data Exchange (ETDEWEB)

Moisture profiles from neutron probe data provide valuable information in site characterization and to supplement ground water monitoring efforts. The neutron probe precision error (reproducibility) is found to be about 0.2 vol% under in situ field conditions where the slope in moisture content with depth is varying slowly. This error is about 2 times larger near moisture spikes (e.g., at the vapor phase notch), due to the sensitivity of the probe response to vertical position errors on the order of 0.5 inches. Calibrations were performed to correct the downhole probe response to the volumetric moisture content determined on core samples. Calibration is sensitive to borehole diameter and casing type, requiring 3 separate calibration relations for the boreholes surveyed here. Power law fits were used for calibration in this study to assure moisture content results greater than zero. Findings in the ...

1997-12-31

398

Tolerance limits of X-ray image intensity  

International Nuclear Information System (INIS)

Evaluation of the tolerance limits of X-ray image density accepted by the radiologist shows that for different kinds of examinations, deviations of more than 50% from optimal density lead to images which cannot be used diagnostically. Within this range diagnostic accuracy shows a distinct maximum and diminishes to the limits by 20%. These figures are related to differences in the intensifying factor of screens, sensitivity of films, sensitometric parameters of film processing as well as the doses employed with automatic exposure control devices, measured in clinical conditions. Maximum permissible tolerance limits of the whole imaging system and of its constituents are discussed using the Gaussian law of error addition. (author).

399

Thomson scattering: a powerful diagnostic tool of plasma physics  

International Nuclear Information System (INIS)

Thomson scattering is the process in which a low-energy photon scatters from a free electron. When a laser pulse propagates through a plasma, the spectrum of the scattered light due to the Thomson scattering is proportional to the power spectrum of the electron density fluctuations, i.e., dynamic form factor, from which various plasma parameters can be inferred, such as electron temperature and plasma flow velocity. After years of development. Thomson scattering has now become a powerful diagnostic tool of plasma physics. (authors)

2008-08-01

400

Somatic radiation risk in X-ray diagnostics  

Energy Technology Data Exchange (ETDEWEB)

The authors give a survey of the somatic radiation risk in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk.

1983-12-01

401

Somatic radiation risk in X-ray diagnostics  

International Nuclear Information System (INIS)

The authors give a survey of the somatic radiation ris in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk. (orig.).

1983-01-01

402

Radiodiagnosis of Ewing's sarcoma of the rib in children  

International Nuclear Information System (INIS)

The results of the examination of 23 children with Ewing's sarcoma of the rib were analyzed: panoramic chest X-rays in 4 projections, spot radiographs of the robs, superexposed pictures, laterograms, urography, angiography, computerized tomography, and scanning of the skeleton. Causes of diagnostic errors made at the first consultation by a physician, were identified. Peculiarities of X-ray signs of tumors of this site in children were studied. Diagnostic difficulties in tumors complicated by pleurisy and in tumors of small sizes with extrapleural growth were shown. Inclusions in the extraoseous tumor component were noted in 8.7% of the cases.

403

Radiation risk in diagnostic radiology  

International Nuclear Information System (INIS)

An attempt was made to quantify the radiation risk of diagnostic radiology. After a general introduction of terms as radiation damage, radiation risk and effective dose equivalent, based on publications of the ICRP, somatic dose indexes were computed for several radiologic investigations, that comprise organ doses committed to red bone marrow, lung, female breast and thyroid with and without considering the rest of the body. The dose for the rest of the body was assumed to be equal to the dose received by the red bone marrow, that is also distributed over the whole body. Neglecting the exposure of the rest of the body resulted in an insignificant increase in the estimated somatic risk, with its experimental determination not being necessary. (author).

1984-01-01

404

Projection techniques in diagnostic radiography discussed with regard to required dose  

International Nuclear Information System (INIS)

The paper presents information in the form of data, tables and diagrams compiled to a broad but very up-to-date survey of required radiation for the various most frequently performed X-ray examinations of patients. The required dose is discussed from the point of view of radiation protection, defining the inevitably administered dose to the skin, the frequency of examinations, and the diagnostic image quality as the main three factors to be observed, as these determine the radiation dose to the patient and to the personnel. The somatic risks of radiography examinations are a point of main interest. (DG).

1990-09-01

405

Post-transplant monitoring of renal allografts: are we there yet?  

British Library Electronic Table of Contents (United Kingdom)

Transplantation has emerged as the therapy of choice for many patients with end organ failure. One of the major goals is to tailor immunosuppressive therapy to the individual needs of every patient to balance the risk for rejection and over-immunosuppression. This will require diagnostic tools that can detect harmful processes in the allograft early, and that can be measured repeatedly. This review will consider recent advances in our understanding of the molecular nature of these processes and how this information is being utilized to design novel diagnostic assays to non-invasively monitor allografts. Highlighted is the need for large-scale prospective multi-centre studies to validate assays that show early promise in single centre studies.

2009-01-01

406

NuMI proton beam diagnostics and control: achieving 2 megawatt capability  

Energy Technology Data Exchange (ETDEWEB)

The NuMI proton beam at Fermilab currently delivers 120 GeV protons to the neutrino production target with design beam power capability to 400 kW. Upgrade capability to 700 kW is being prepared, with planning toward delivering 2.3 MW beam provided by the Project X accelerator upgrade plan. We report on the system of beam diagnostics and control used in operation of the NuMI beam. Also considered are the steps to provide a robust system for transport and targeting beam of 2 MW and beyond.

2008-10-01

407

GPLS VME MODULE: A DIAGNOSTIC AND DISPLAY TOOL FOR NSLS MICRO SYSTEMS.  

Energy Technology Data Exchange (ETDEWEB)

The General Purpose Light Source VME module is an integral part of every front-end micro in the NSLS control system. The board incorporates features such as a video character generator, clock signals, time-of-day clock, a VME bus interrupter and general-purpose digital inputs and outputs. This module serves as a valuable diagnostic and real-time display tool for the micro development as well as for the final operational systems. This paper describes the functions provided by the board for the NSLS micro control monitor software.

1999-03-29

408

Evaluation of the chest radiography using Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Chest radiograms obtained by using Fuji Computed Radiography (FCR) system were compared to conventional film/screen radiograms. The FCR images showed better image quality in diagnostic information than the conventional chest images. In FCR, the radiation exposure to patient for chest examination could be reduced up to one tenths of conventional chest examination. The main advantages or FCR were considered to depend on the contrast processing and frequency processing properties. The use of FCR in clinical work may improve both diagnostic quality and radiation exposure.

1991-12-01

409

Electron temperature diagnostics in the RFX reversed field pinch experiment  

Energy Technology Data Exchange (ETDEWEB)

The paper presents an integrated approach to the problem of electron temperature diagnostics of the plasma in a reversed field pinch. Three different methods, sampling different portions of the electron distribution function, are adopted, namely Thomson scattering, soft X-ray spectroscopy by pulse-height analysis and filtered soft X-ray intensity ratio. A careful analysis of the different sources of systematic errors is performed and a novel statistical approach is adopted to mutually validate the three independent measurements. A satisfactory agreement is obtained over a large range of experimental conditions, indicating that in the plasma core the energy distribution function is well represented by a maxwellian. (author)

2000-08-01

410

Efficient application of medical imaging methods. Graded diagnostics for surgical and internal medical problems. Rationeller Einsatz bildgebender Verfahren. Gestufte Diagnostik bei chirurgischen und internistischen Krankheitsbildern  

Energy Technology Data Exchange (ETDEWEB)

The book is intended as a source of information for general practioners and for medical students doing their practical training. Efficient application of imaging methods is explained with great emphasis on practical aspects, concentrating on typical tasks to be solved for adult patients with internal disease or surgical problems. The material is arranged by various organic systems of the body. Graded diagnostics for a stepwise approach to the final diagnosis is the concept described, and is shown to be of advantage to the patient and in terms of cost and time.

1985-01-01

411

Clinical magnetic resonance imaging with nuclear medicine correlation  

Energy Technology Data Exchange (ETDEWEB)

The current role of magnetic resonance imaging (MRI) in different organ systems is discussed and compared to nuclear medicine and to other available clinical diagnostic modalities. The value of optimizing radiofrequency pulse sequence selection to provide additional tissue characterization is also described. The results of nuclear medicine and MRI studies in 56 patients are compared to evaluate the clinical diagnostic contribution of each imaging modality for various pathological processes. In addition, the state-of-the-art MRI systems and future development in MRI technology with its potential contribution is defined.

1985-08-01

412

Performance of Brazilian thermoluminescent CaSO{sub 4}: Dy pellets in standard diagnostic radiology beams  

Energy Technology Data Exchange (ETDEWEB)

The high sensitivity of CaSO{sub 4}: Dy as a thermoluminescent material is a great advantage when dealing with low dose levels, as in diagnostic radiology procedures. However, these kinds of dosemeters present a high energy dependence that must be precisely determined in the energy range of interest. Dosimetric pellets of CaSO{sub 4}: Dy are produced at IPEN since the end of the 80 Th decade. These pellets are produced in three forms: conventional CaSO{sub 4}: Dy (50 mg); thin CaSO{sub 4}: Dy (20 mg) and CaSO{sub 4}: Dy + 10% C (20 mg). The main applications of these dosemeters are in personal and environmental dosimetry. In this study, CaSO{sub 4}: Dy pellets produced at IPEN were evaluated in diagnostic radiology standard beams. These qualities are based on the IEC 61267 standard, and they were established at an industrial X-ray system Pantak/Seifert, model ISOVOLT 160HS. Former studies evaluated CaSO{sub 4}: Dy of different origins in ...

2006-07-01

413

The response of quartz crystals coated with thin fatty acid film to organic gases  

Energy Technology Data Exchange (ETDEWEB)

We tried to apply a quartz crystal as a sensor by using the resonant frequency and the resistance properties of quartz crystals. Four kinds of fatty acids that have the same head groups were coated on the surfaces of the quartz crystals, and the shift of the resonant frequency and the resistance were observed based on the lengths of the tail groups. Myristic acid (C{sub 14}), palmitic acid (C{sub 16}), stearic acid (C{sub 18}), and arachidic acid (C{sub 20}) were deposited on the surfaces of quartz crystals by using the Langmuir-Blodgett (LB) method. As a result, the resonant frequency change was more sensitive to high molecular-weight fatty acids than to low molecular-weight ones. We also observed the effect of temperature on stearic acid LB films, and the response properties of quartz crystals coated with stearic-acid LB films to organic gases were investigated. As a result, the sensitivity of quartz crystals to organic gases was higher for higher ...

1999-07-01

414

Study on biosorption kinetics and thermodynamics of uranium by Citrobacter freudii  

Energy Technology Data Exchange (ETDEWEB)

Biosorption has been developed as an effective and economic method to treat wastewater containing low concentrations of metal pollutants. In this study, a bacterium, Citrobacter freudii, was used as a biosorbent to adsorb uranium ions. The thermodynamics and kinetics of this adsorption, as well as its mechanism, were investigated. The results indicated that the biosorption rate could be better described by a pseudo 2nd-order model than a pseudo 1st-order model. The adsorption of U (VI) proceeded very rapidly in the first 30 min and subsequently slowed down continuously for a long period. The biosorption isotherm of uranium by C. freudii could be described well by the Langmuir or Freundlich isotherm, and the latter was better. The thermodynamics parameters, {delta}H{sup o}, {delta}G{sup o}, and {delta}S{sup o} were calculated according to the results of the experiment, which showed this biosorption as being endothermic and spontaneous. The authors investigated the ...

2008-01-15

415

Studies on the biosorption of uranium by a thermotolerant, ethanol-producing strain of Kluyveromyces marxianus  

Energy Technology Data Exchange (ETDEWEB)

The ability of residual biomass from the thermotolerant ethanol-producing yeast strain Kluyveromyces marxianus IMB3 to function as a biosorbent for uranium has been examined. It was found that the biomass had an observed maximum biosorption capacity of 120 mg U/g dry weight of biomass. The calculated value for the biosorption maximum, obtained by fitting the data to the Langmuir model was found to be 130 mg U/g dry weight biomass. Maximum biosorption capacities were examined at a number of temperatures and both the observed and calculated values obtained for those capacities increased with increasing temperature. Decreasing the pH of the biosorbate solution resulted in a decrease in uptake capacity. When biosorption reactions were carried out using sea-water as the diluent it was found that the maximum biosorption capacity of the biomass increased significantly. Using transmission electron microscopy, uranium crystals were shown to be concentrated on the outer ...

1997-06-01

416

Selective adsorption of uranium on activated charcoal from electrolytic aqueous solutions  

Energy Technology Data Exchange (ETDEWEB)

Adsorption of uranium onto various solids is important from purification, environmental, and radioactive waste disposal points of view. Adsorption of uranium on activated charcoal has been studied as a function of shaking time, amount of adsorbent, pH, concentration of adsorbate, and temperature. Uranium adsorption obeys the Langmuir isotherm. {Delta}H{degrees} and {Delta}S{degrees} were calculated from the slope and intercept of plots ln K{sub D} vs 1/T. The influence of different anions and cations on uranium adsorption has been examined. The adsorption of other metal ions on activated charcoal has been studied under specified conditions to check its selectivity; consequently, uranium was removed from Cs, Ba, Zn, and Co. More than 98% adsorbed uranium on activated charcoal can be recovered with 65 ml of 3 M HNO{sub 3} solution. A wavelength dispersive x-ray fluorescence spectrometer was used for measuring uranium concentration.

1992-02-01

417

Removal of phosphate by mesoporous ZrO{sub 2}  

Energy Technology Data Exchange (ETDEWEB)

A type of mesoporous ZrO{sub 2} was synthesized and its phosphate removal potential was investigated in this study. The adsorption isotherm, pH effect, ionic strength effect and desorption were examined in batch experiments. The adsorption data fitted well to the Langmuir model with which the maximum P adsorption capacity was estimated to be 29.71 mg P/g. The amount of phosphate adsorbed increased rapidly in the first 5 h and slowly towards the end of the run, suggesting the possible monolayer coverage of phosphate ions on the surface of the adsorbent. The phosphate adsorption tended to increase with a decrease of pH and an increase of ionic strength. A phosphate desorbability of approximately 60% was observed with 0.5 M NaOH, which indicated a relatively strong bonding between the adsorbed PO{sub 4}{sup 3-} and the sorptive sites on the surface of the adsorbent. The immobilization of phosphate probably occurs by the mechanisms of ion exchange and physicochemical ...

2008-03-01

418

Investigation of the evaporation of rare earth chlorides in a LiCl-KCl molten salt  

International Nuclear Information System (INIS)

Uranium dendrites which were deposited at a solid cathode of an electrorefiner contained a certain amount of salts. These salts should be removed for the recovery of pure metal using a cathode processor. In the uranium deposits from the electrorefining process, there are actinide chlorides and rare earth chlorides in addition to uranium chloride in the LiCl-KCl eutectic salt. The evaporation behaviors of the actinides and rare earth chlorides in the salts should be investigated for the removal of salts in the deposits. Experiments on the salt evaporation of rare earth chlorides in a LiCl-KCl eutectic salt were carried out. Though the vapor pressures of the rare earth chlorides were lower than those of the LiCl and KCl, the rare earth chlorides were co-evaporized with the LiCl-KCl eutectic salt. The Hertz-Langmuir relation was applied for this evaporation, and also the evaporation rates of the salt were obtained. The co-evaporation of the rare earth chlorides and ...

2011-02-01

419

Intra-cellular transport of single-headed molecular motors KIF1A  

CERN Document Server

Motivated by recent experiments on KIF1A, a representative member of single-headed kinesin motor proteins family, we develop a theoretical model of intra-cellular transport by mutually interacting molecular motors. The model explicitly accounts not only for the hydrolysis of ATP, but also for the ratchet mechanism which is believed to drive each individual KIF1A motor. We study the model by a combination of analytical and numerical techniques. A remarkable feature of this model is that all the parameters in it can be completely evaluated from experimental data. Our results in the dilute limit are in excellent quantitative agreement with the empirical data from single molecule experiments. In the high density regime the predictions of the model also agree qualitatively with the corresponding experimental observations. We derive a phase diagram that shows the influence of hydrolysis and Langmuir kinetics on the collective spatio-temporal organization of the motors. ...

2005-01-01

420

Hybrid porous phosphate heterostructures as adsorbents of Hg(II) and Ni(II) from industrial sewage  

British Library Electronic Table of Contents (United Kingdom)

Porous phosphate heterostructures (PPH), functionalized with different ratios of aminopropyl and mercaptopropyl groups, labelled as Nx=5,25,50-PPH and Sx=5,25,50-PPH, respectively, were tested as adsorbents for Ni(II) and Hg(II) found in industrial sewage from electroplating processes and button battery recycling. X-ray diffraction was used to study the structures. The specific surface area of the pristine material (PPH) was 620m^2g^-^1, whereas the specific surface areas of the modified mercaptopropyl (S5-PPH) and aminopropyl (N5-PPH) were 472 and 223m^2g^-^1, respectively. The adsorption data were fitted to a Langmuir isotherm model. The S5-PPH material was saturated by 120mmol Hg(II) per 100g of material, whereas for Ni(II) adsorption, N25-PPH material displayed the highest adsorption w...

2011-01-01

421

Exploring multi-metal biosorption by indigenous metal-hyperresistant Enterobacter sp. J1 using experimental design methodologies  

Energy Technology Data Exchange (ETDEWEB)

A novel experimental design, combining mixture design and response surface methodology (RSM), was developed to investigate the competitive adsorption behavior of lead, copper and cadmium by an indigenous isolate Enterobacter sp. J1 able to tolerate high concentrations of a variety of heavy metals. Using the proposed combinative experimental design, two different experiment designs in a ternary metal biosorption system can be integrated to a succinct experiment and the number of experimental trials was markedly reduced from 38 to 26 by reusing the mutual experimental data. Triangular contour diagrams and triangular three-dimensional surface plots were generated to describe the ternary metal biosorption equilibrium data in mixture design systems. The results show that the preference of metal sorption of Enterobacter sp. J1 decreased in the order of Pb{sup 2+} > Cu{sup 2+} > Cd{sup 2+}. The presence of other metals resulted in a competitive effect. The influence of the other ...

2008-05-01

422

Equilibrium, thermodynamic and kinetic studies for the biosorption of aqueous lead(II) ions onto the seed husk of Calophyllum inophyllum  

British Library Electronic Table of Contents (United Kingdom)

Biosorption of lead(II) ions from aqueous solution onto the seed husk of Calophyllum inophyllum was investigated in a batch system. Equilibrium, thermodynamics and kinetic studies were conducted by considering the effects of pH, initial metal ion concentration, contact time, and temperature. The results showed that the uptake of the metal ions increased with increase in initial metal ion concentration. The pH for optimum adsorption was 4 for the Pb(II) ions (q=4.86mg/g and 97.2% adsorption). Langmuir isotherm described the biosorption of Pb(II) ions onto the biomass (R^2=0.9531) better than the Freundlich model (R^2=0.7984), and the Temkin model (R^2=0.8761). Biosorption kinetics data obtained for the metal ions sorption were fitted using pseudo-first-order and pseudo-second-order. It was ...

2010-01-01

423

Enhanced corrosion resistance of mild steel in hydrochloric acid solution by new thiadiazole derivatives: Electrochemical, theoretical and XPS studies  

Energy Technology Data Exchange (ETDEWEB)

In this work, a new class of thiadiazole derivatives, namely 3,5-bis(2-thienyl)-1,3,4-thiadiazole (2-TTH) and 3,5-bis(3-thienyl)-1,3,4-thiadiazole (3-TTH), have been studied as possible corrosion inhibitors for mild steel in molar hydrochloric acid (1M HCl). Polarisation curves and AC impedance methods have been used. These studies have shown that the thiadiazole derivatives were very good inhibitors for mild steel in 1M HCl. Comparison of results showed that 3-TTH was the best inhibitor. The potential of zero charge (PZC) of mild steel was studied by ac impedance method, and the mechanism of adsorption has been predicted. X-ray photoelectron spectroscopy surface analysis with thiadiazole derivatives shows that it chemisorbed at the mild steel/HCl interface. The adsorption of these inhibitors followed Langmuir's adsorption isotherm. The electronic properties of 2-TTH and 3-TTH, obtained using the AM1 semi-empirical quantum chemical approach, were ...

2004-07-01

424

Effect of some tripodal bipyrazolic compounds on C38 steel corrosion in hydrochloric acid solution  

British Library Electronic Table of Contents (United Kingdom)

The corrosion inhibition of C38 steel in molar HCl by N,N-bis[2-(3,5-dimethyl-1H-pyrazol-1-yl)ethyl]buthylamine (P1) and 5-{N,N-bis[2-(3,5-dimethyl-1H-pyrazol-1-yl)ethyl] amino} pentanol (P2) has been investigated at 308?K using electrochemical and weight loss measurements. Measurements show that these compounds act as good inhibitors without changing the mechanism of the corrosion process. Moreover, the inhibiting efficiency increases with the increase in concentration of the studied inhibitors. Compound P2 showed better protection properties even at relatively higher temperatures when compared to P1. The associated activation corrosion and free adsorption energies have been determined. P1 and P2 are adsorbed on the C38 steel surface according to a Langmuir isotherm adsorption model.

2010-01-01

425

Corrosion inhibition of mild steel by alkylimidazolium ionic liquids in hydrochloric acid  

Energy Technology Data Exchange (ETDEWEB)

The acid corrosion inhibition process of mild steel in 1 M HCl by 1-butyl-3-methylimidazolium chlorides (BMIC) and 1-butyl-3-methylimidazolium hydrogen sulfate ([BMIM]HSO{sub 4}) has been investigated using electrochemical impedance, potentiodynamic polarization and weight loss measurements. Potentiodynamic polarization studies indicate the studied inhibitors are mixed type inhibitors. For both inhibitors, the inhibition efficiency increased with increase in the concentration of the inhibitor and the effectiveness of the two inhibitors are in the order [BMIM]HSO{sub 4} > BMIC. The adsorption of the inhibitors on mild steel surface obeyed the Langmuir's adsorption isotherm. The effect of temperature on the corrosion behavior in the presence of 5 x 10{sup -3} M of inhibitors was studied in the temperature range of 303-333 K. The associated activation energy of corrosion and other thermodynamic parameters such as enthalpy of activation ({delta}H), ...

2009-02-15

426

Corrosion inhibition of mild steel by alkylimidazolium ionic liquids in hydrochloric acid  

International Nuclear Information System (INIS)

The acid corrosion inhibition process of mild steel in 1 M HCl by 1-butyl-3-methylimidazolium chlorides (BMIC) and 1-butyl-3-methylimidazolium hydrogen sulfate ([BMIM]HSO_4) has been investigated using electrochemical impedance, potentiodynamic polarization and weight loss measurements. Potentiodynamic polarization studies indicate the studied inhibitors are mixed type inhibitors. For both inhibitors, the inhibition efficiency increased with increase in the concentration of the inhibitor and the effectiveness of the two inhibitors are in the order [BMIM]HSO_4 > BMIC. The adsorption of the inhibitors on mild steel surface obeyed the Langmuir's adsorption isotherm. The effect of temperature on the corrosion behavior in the presence of 5 x 10"-"3 M of inhibitors was studied in the temperature range of 303-333 K. The associated activation energy of corrosion and other thermodynamic parameters such as enthalpy of activation (#DELTA#H), entropy of activation ...

2009-02-15

427

Characterization of interactions of coal surface with solvent by flow microcalorimetric measurement. 3; Netsuryo sokutei ni yoru sekitan hyomen to yozai tono sogo sayo no hyoka. 3  

Energy Technology Data Exchange (ETDEWEB)

An investigation was given on the relationship between methanol adsorbing behavior of reformed coal surface and oxygen containing functional groups in coal. Akabira bituminous coal was air-oxidized or Yallourn brown coal was decarbonated in oil as a reformation treatment. Both of the treated and untreated coals showed an adsorption heat curve of the Langmuir type. The Akabira coal had its oxygen content and the adsorption heat increased as a result of the air oxidizing reformation treatment. The Yallourn coal had its oxygen content and adsorption heat decreased as a result decarbonation reformation treatment. Oxygen containing functional groups act as strong adsorption sites for methanol, and the maximum adsorption amount depends on oxygen content in the coals. Since the coal surface is non-uniform in terms of energy, methanol is adsorbed first into sites with higher molar adsorption heat, and then into lower sites sequentially. Therefore, distribution of the molar ...

1996-10-28

428

Cadmium biosorption rate in protonated Sargassum biomass  

Energy Technology Data Exchange (ETDEWEB)

Biosorption of the heavy metal ion Cd{sup 2+} by protonated nonliving brown alga Sargassum fluitans biomass was accompanied by the release of hydrogen protons from the biomass. The uptake of cadmium and the release of proton matched each other throughout the biosorption process. The end-point titration methodology was used to maintain the constant pH 4.0 for developing the dynamic sorption rate. The sorption isotherm could be well represented by the Langmuir sorption model. A mass transfer model assuming the intraparticle diffusion in a one-dimensional thin plate as a controlling step was developed to describe the overall biosorption rate of cadmium ions in flat seaweed biomass particles. The overall biosorption mathematical model equations were solved numerically yielding the effective diffusion coefficient D{sub e} about 3.5 {times} 10{sup {minus}6} cm{sup 2}/s. This value matches that obtained for the desorption process and is approximately half of that of the ...

1999-03-01

429

Biosorption of copper (II) onto immobilized cells of Pycnoporus sanguineus from aqueous solution: Equilibrium and kinetic studies  

Energy Technology Data Exchange (ETDEWEB)

The ability of white-rot fungus, Pycnoporus sanguineus to adsorb copper (II) ions from aqueous solution is investigated in a batch system. The live fungus cells were immobilized into Ca-alginate gel to study the influence of pH, initial metal ions concentration, biomass loading and temperature on the biosorption capacity. The optimum uptake of Cu (II) ions was observed at pH 5 with a value of 2.76 mg/g. Biosorption equilibrium data were best described by Langmuir isotherm model followed by Redlich-Peterson and Freundlich models, respectively. The biosorption kinetics followed the pseudo-second order and intraparticle diffusion equations. The thermodynamic parameters enthalpy change (10.16 kJ/mol) and entropy change (33.78 J/mol K) were determined from the biosorption equilibrium data. The FTIR analysis showed that -OH, -NH, C-H, C=O, -COOH and C-N groups were involved in the biosorption of Cu (II) ions onto immobilized cells of P. sanguineus. The immobilized cells ...

2009-01-15

430

Biosorption of cadmium(II), zinc(II) and lead(II) by Penicillium simplicissimum: Isotherms, kinetics and thermodynamics  

Energy Technology Data Exchange (ETDEWEB)

The isotherms, kinetics and thermodynamics of Cd(II), Zn(II) and Pb(II) biosorption by Penicillium simplicissimum were investigated in a batch system. The effects of pH, initial metal ions concentration, biomass dose, contact time, temperature and co-ions on the biosorption were studied. Adsorption data were well described by both the Redlich-Peterson and Langmuir model. Chemical ion-exchange was found to be an important process based on free energy value from Dubini-Radushkevich isotherm for all metal ions. The results of the kinetic studies of all metal ions at different temperature showed that the rate of adsorption followed the pseudo second-order kinetics well. The thermodynamics constants {delta}G{sup o}, {delta}H{sup o} and {delta}S{sup o} of the adsorption process showed that biosorption of Cd(II), Zn(II) and Pb(II) ions on Penicillium simplicissimum were endothermic and spontaneous.

2008-12-30

431

Biosorption of cadmium(II) from aqueous solution by red algae (Ceramium virgatum): Equilibrium, kinetic and thermodynamic studies  

Energy Technology Data Exchange (ETDEWEB)

The biosorption characteristics of Cd(II) ions using the red alga (Ceramium virgatum) were investigated. Experimental parameters affecting the biosorption process such as pH, contact time, biomass dosage and temperature were studied. Langmuir, Freundlich and Dubinin-Radushkevich (D-R) models were applied to describe the biosorption isotherms. The biosorption capacity of C. virgatum biomass for Cd(II) ions was found to be 39.7 mg/g. From the D-R isotherm model, the mean free energy was calculated as 12.7 kJ/mol, indicating that the biosorption of Cd(II) the metal ions was taken place by chemisorption. The calculated thermodynamic parameters ({delta}G{sup o}, {delta}H{sup o} and {delta}S{sup o}) showed that the biosorption of Cd(II) ions onto C. virgatum was feasible, spontaneous and exothermic at 293-323 K. Evaluation of experimental data in terms of biosorption kinetics showed that the biosorption of Cd(II) C. virgatum followed well pseudo-second-order kinetics.

2008-09-15

432

Biosorption of Ni (II) by Schizosaccharomyces pombe: kinetic and thermodynamic studies  

British Library Electronic Table of Contents (United Kingdom)

The potential of the dried yeast, wild-type Schizosaccharomyces pombe, to remove Ni(II) ion was investigated in batch mode under varying experimental conditions including pH, temperature, initial metal ion concentration and biosorbent dose. Optimum pH for biosorption was determined as 5.0. The highest equilibrium uptake of Ni(II) on S. pombe, q e, was obtained at 25??C as 33.8?mg?g?1. It decreased with increasing temperature within a range of 25?50??C denoting an exothermic behaviour. Increasing initial Ni(II) concentration up to 400?mg?L?1 also elevated equilibrium uptake. No more adsorption took place beyond 400?mg?L?1. Equilibrium data fitted better to Langmuir model rather than Freundlich model. Sips, Redlich?Peterson, and Kahn isotherm equations modelled the investigated system with a...

2011-01-01

433

Antibiotic interaction with phospholipid monolayers  

Energy Technology Data Exchange (ETDEWEB)

We studied the interactions of tetracycline (TC) antibiotic molecules with phospholipid monolayers with the two-fold aim of elucidating the mechanism of action and providing a first step for the realization of bio-mimetic sensors for such drugs by means of the Langmuir-Blodgett technique. We examined spreading monolayers of three phospholipids in the presence of tetracycline in the subphase by means of surface pressure-area and surface potential-area isotherms as a function of bulk pH. We selected phospholipids with hydrophobic chains of the same length but polar head groups differing either in dimensions and protonation equilibria, i.e. dipalmitoylphosphatidylcholine (DPPC), dipalmitoylphosphatidylethanolamine (DPPE) and dipalmitoylphosphatidic acid (DPPA). The interaction of tetracycline with the three phospholipids was found to be highly dependent on the electric charge of the antibiotic and on the ionization state of the lipid. Significant interactions are ...

2002-12-01

434

Corrosion inhibition of steel in crude oil storage tanks  

Energy Technology Data Exchange (ETDEWEB)

The corrosion behavior of steel in water from certain oil fields with various organic inhibitors was studied by applying potentiodynamic technique at pH 5.9. The inhibitors which were used include 2-methylbenzimidazole (I), 2-mercaptobenzimidazole (II), 2-mercapto-5-methylbenzimidazole (III), and 2-mercaptothiazole (IV). The inhibiting efficiency of the different additives was evaluated from their anodic and cathodic polarization curves at different temperatures. A comparative study of curve fitting procedures using the kinetic thermodynamic model and those utilizing well-known adsorption isotherms was undertaken. Three types of isotherms were used, Langmuir, Frumkin and Flory-Huggins isotherm. The results show that the kinetic-thermodynamic model and Flory-Huggins isotherms are more suitable to fit the data for the four inhibitors, at all applied temperatures. From the values of binding constants, K, the order of inhibitor efficiency is: III > IV > ...

2003-04-01

435

Polyp measurement based on CT colonography and colonoscopy: variability and systematic differences  

Energy Technology Data Exchange (ETDEWEB)

To assess the variability and systematic differences in polyp measurements on optical colonoscopy and CT colonography. Gastroenterologists measured 51 polyps by visual estimation, forceps comparison and linear probe. CT colonography observers randomly assessed polyp size two-dimensionally (abdominal and intermediate window) and three-dimensionally (manually and semi-automatically). Linear mixed models were used to assess the variability and systematic differences between CT colonography and optical colonoscopy techniques. The variability of forceps and linear probe measurements was comparable and both showed less variability than measurement by visual assessment. Measurements by linear probe were 0.7 mm smaller than measurements by visual assessment or by forceps. The variability of all CT colonography techniques was lower than for measurements by forceps or visual assessment and sometimes lower (only 2D intermediate window ...

2010-06-15

436

Corrosion probes for fireside monitoring in coal-fired boilers  

Energy Technology Data Exchange (ETDEWEB)

Corrosion probes are being developed and combined with an existing measurement technology to provide a tool for assessing the extent of corrosion of metallic materials on the fireside in coal-fired boilers. The successful development of this technology will provide power plant operators the ability to (1) accurately monitor metal loss in critical regions of the boiler, such as waterwalls, superheaters, and reheaters; and (2) use corrosion rates as process variables. In the former, corrosion data could be used to schedule maintenance periods and in the later, processes can be altered to decrease corrosion rates. The research approach involves laboratory research in simulated environments that will lead to field tests of corrosion probes in coal-fired boilers. Laboratory research has already shown that electrochemically-measured corrosion rates for ash-covered metals are similar to actual mass loss corrosion rates. Electrochemical tests conducted ...

2005-01-01

437

Computer modelling of eddy current probes for ISI of pressure tube/calandria tube assemblies in PHWRs  

International Nuclear Information System (INIS)

Non-destructive Evaluation (NDE) plays a major role in ensuring the safe and reliable operation of PHWRs which are the mainstay of India's nuclear power programme. An important in-service inspection (ISI) requirement in these reactors is carried out through Eddy Current Testing (ECT) of the pressure tube (PT)/calandria tube (CT) assemblies. The material of construction of these assemblies is zircaloy-2. The two main objectives of this ISI are the detection of garter spring between CT and PT and the profiling of gap between CT and PT. The paper discusses the work carried out at the authors' laboratory on the development of ECT probes for ISI of PT/CT assemblies. Emphasis has been given on the work done on the design and optimisation of the probes using computer modeling. A 2-D finite element code has been developed for this purpose. The code is developed around a diffusion equation which can be derived from Maxwell's equations governing the ...

1991-12-01

438

A sample preparation for quantitative determination of magnesium in individual lymphocytes by electron probe X-ray microanalysis.  

Science.gov (United States)

We present a sample preparation method for measuring magnesium in individual whole lymphocytes by electron probe X-ray microanalysis. We use Burkitt's lymphoma cells in culture as the test sample and compare X-ray microanalysis of individual cells with atomic absorption analysis of pooled cell populations. We determine the magnesium peak-to-local continuum X-ray intensity ratio by electron probe X-ray microanalysis and calculate a mean cell magnesium concentration of 39 +/- 19 mmol/kg dry weight from analysis of 100 cells. We determine a mean cell magnesium concentration of 34 +/- 4 mmol/kg dry weight by atomic absorption analysis of pooled cells in three cell cultures. The mean cell magnesium concentrations determined by the two methods are not significantly different. We find a 10% coefficient of variation for both methods of analysis and a 30% coefficient of variation in magnesium concentration among individual cells by electron ...

1986-01-01

439

A sample preparation for quantitative determination of magnesium in individual lymphocytes by electron probe X-ray microanalysis  

International Nuclear Information System (INIS)

We present a sample preparation method for measuring magnesium in individual whole lymphocytes by electron probe X-ray microanalysis. We use Burkitt's lymphoma cells in culture as the test sample and compare X-ray microanalysis of individual cells with atomic absorption analysis of pooled cell populations. We determine the magnesium peak-to-local continuum X-ray intensity ratio by electron probe X-ray microanalysis and calculate a mean cell magnesium concentration of 39 +- 19 mmol/kg dry weight from analysis of 100 cells. We determine a mean cell magnesium concentration of 34 +- 4 mmol/kg dry weight by atomic absorption analysis of pooled cells in three cell cultures. The mean cell magnesium concentrations determined by the two methods are not significantly different. We find a 10% coefficient of variation for both methods of analysis and a 30% coefficient of variation in magnesium concentration among individual cells by electron ...

1986-01-01

440

Stochastic risk estimation from medical x-ray diagnostic examinations, 2  

International Nuclear Information System (INIS)

The risks of genetic, leukemia and malignant diseases from medical X-ray diagnostic examinations were estimated using the frequency of radiographic and fluoroscopic exposures per diagnostic examination, child expectancy, leukemia and malignancy significant factors, and using a weighting factor determined on the basis of data concerning the cancer mortality among atomic bomb survivors in Nagasaki and of a recommendation of International Commission of Radiological Protection. The organ or tissue doses with respect to the stochastic risks were determined with ionization chambers and thermoluminescent dosimeters placed at the positions of the organs or tissues in a RANDO woman phantom which was exposed to diagnostic X-rays according to technical factors of typical radiographic and fluoroscopic examinations obtained from a nationwide survey. The resultant risks by age-group and type of radiographic and fluoroscopic examination ...

1981-01-01

441

Diagnostics aid for mass spectrometer trouble-shooting  

International Nuclear Information System (INIS)

The MS Expert system provides problem diagnostics for instruments used in the Mass Spectrometry Laboratory (MSL). The most critical results generated on these mass spectrometers are the uranium concentration and isotopic content data used for process control and materials accountability at the Idaho General Processing Plant. The two purposes of the system are: (1) to minimize instrument downtime and thereby provide the best possible support to the Plant, and (2) to improve long-term data quality. This system combines the knowledge of several experts on mass spectrometry to provide a diagnostic tool, and can make these skills available on a more timely basis. It integrates code written in the Pascal language with a knowledge base entered into a commercial expert system shell. The user performs some preliminary status checks, and then selects from among several broad diagnostic categories. These initial steps provide input to ...

442

Versatile high intensity plasma sputter heavy negative ion source  

Energy Technology Data Exchange (ETDEWEB)

A multicusp magnetic field plasma surface ion source, normally used for H/sup -/ ion beam formation, has been utilized for the generation of high intensity, pulsed, heavy negative ion beams suitable for a variety of uses including tandem electrostatic accelerator/synchrotron injection applications. Sputter probe voltage limited total ion currents of 5.5, 8.2, 5.1 and 4.5 mA (peak intensity) have been produced from Au, Cu, Ni and CuO sputter probes, respectively. The mass distributions of these ion beams are found to be dominated by Au/sup -/, Cu/sup -/, Ni/sup -/ and O/sup -/ atomic species, respectively. The source offers the interesting prospect of providing cw negative ion beams at mA intensity levels of the commonly used semiconducting material dopants (e.g. B/sup -/, P/sup -/, As/sup -/ and Sb/sup -/) as well as O/sup -/ for isolation barrier formation. Illustrative examples of intensity versus time and the mass distribution of ion beams ...

1988-07-01

443

Monitoring power plant fireside corrosion using corrosion probes  

Energy Technology Data Exchange (ETDEWEB)

The ability to monitor the corrosion degradation of key components in fossil fuel power plants is of utmost importance for Futuregen and ultra-supercritical power plants. Fireside corrosion occurs in the high temperature sections of energy production facilities due to a number of factors: ash deposition, coal composition, thermal gradients, and low NOx conditions, among others. Problems occur when equipment designed for either oxidizing or reducing conditions is exposed to alternating oxidizing and reducing conditions. This can happen especially near the burners. The use of low NOx burners is becoming more commonplace and can produce reducing environments that accelerate corrosion. One method of addressing corrosion of these surfaces is the use of corrosion probes to monitor when process changes cause corrosive conditions. In such a case, corrosion rate could become a process control variable that directs the operation of a coal combustion or coal gasification ...

2005-01-01

444

Evolution of surface roughness in silicon X-ray mirrors exposed to a low-energy ion beam  

International Nuclear Information System (INIS)

The possibility of smoothening aspherical X-ray mirrors by irradiation of the surface with a low-energy ion beam is investigated. Nanofocusing being the primary application of these mirrors the ion beam conditions must be optimized to achieve a surface roughness of the order of 0.1-0.2 nm. To address this issue a first study was performed on silicon flat substrates etched using ion energies ranging from 400 to 1200 eV. A second study consisted of eroding the silicon surface while varying the ion grazing incidence angle between 10 deg. and 90 deg. for a fixed value of the ion energy. The surface topography of the samples was characterized at various scales using atomic force microscopy (probed area: 1-10 ?m2), interferential optical microscopy (probed area: 1 mm2) and X-ray scattering (probed area: 100 mm2). Finally, a study by AFM of the evolution of the surface finish level of a silicon mirror after ion erosion at various ...

2010-05-01

445

Electrochemical detection of DNA hybridization based on silver-enhanced gold nanoparticle label  

Energy Technology Data Exchange (ETDEWEB)

An electrochemical detection method for analyzing sequence-specific DNA using gold nanoparticle DNA probes and subsequent signal amplification step by silver enhancement is described. The assay relies on the electrostatic adsorption of target oligonucleotides onto the sensing surface of the glassy carbon electrode (GCE) and its hybridization to the gold nanoparticle-labeled oligonucleotides DNA probe. After silver deposition onto gold nanoparticles, binding events between probe and target were monitored by the differential pulse voltammetry (DPV) signal of the large number of silver atoms anchored on the hybrids at the electrode surface. The signal intensity difference permits to distinguish between the match of two perfectly matched DNA strands and the near-perfect match where just one base pair was wrong. Coupled with this 'nanoparticle-promoted' reduction of silver signal amplification method, the ...

2002-10-03

446

Char particle fragmentation and its effect on unburned carbon during pulverized coal combustion. Quarterly report, October 1, 1993--December 31, 1993  

Energy Technology Data Exchange (ETDEWEB)

The information reported is for the period October I to December 31, 1993. During this quarter, activities were undertaken in Task 2. Oxygen concentrations were measured in the post-flame region of the entrained flow reactor. The sampling probe was used for the hot gas tests to sample the gas stream. Samples were injected into a gas chromatograph to determine the oxygen concentration. Results agreed with thermoequilibrium calculations that yield equilibrium compositions based on the stoichiometry of the feed gases. The axial temperature distribution along the reactor centerline was measured using a silica-coated platinum-rhodium thermocouple. Two coating techniques were tested and it was found that flame-plating silica to the thermocouple wires produced a thinner coating than a ceramic adhesive technique and therefore a smaller radiation correction. Other activities this quarter included the fabrication of a solids sampling probe support ...

1994-02-01

447

The accuracy and reverse effects of thallium myocardial SPECT using adenosine triphosphate loading in the diagnosis of coronary artery disease. Comparison with other loading methods semiquantitatively  

Energy Technology Data Exchange (ETDEWEB)

The adverse effects and diagnostic accuracy of thallium-201 myocardial SPECT after intravenous infusion of adenosine triphosphate (ATP) were studied and compared with SPECT examinations with other type of loading. The subjects of the study were 147 patients with or without coronary artery disease, who underwent some type of loading SPECT and coronary arteriography (CAG) within 30 days. Myocardial ischemia was evaluated qualitatively in SPECT and was compared with CAG for the diagnostic accuracy of coronary artery disease. The degree of myocardial uptake defect was also calculated semiquantitatively using visual scoring method and compared with coronary artery severity score. The adverse effects occurred in 46.7% of ATP loading SPECT which was more frequent that DIP loading SPECT, but all of them were transient and mild. As for the diagnostic ability the ATP loading SPECT was as effective as other type of loading in ...

1999-09-01

448

Radiation hardening of diagnostics  

International Nuclear Information System (INIS)

The world fusion program has advanced to the stage where it is appropriate to construct a number of devices for the purpose of burning DT fuel. In these next-generation experiments, the expected flux and fluence of 14 MeV neutrons and associated gamma rays will pose a significant challenge to the operation and diagnostics of the fusion device. Radiation effects include structural damage to materials such as vacuum windows and seals, modifications to electrical properties such as electrical conductivity and dielectric strength and impaired optical properties such as reduced transparency and luminescence of windows and fiber optics during irradiation. In preparation for construction and operation of these new facilities, the fusion diagnostics community needs to work with materials scientists to develop a better understanding of radiation effects, and to undertake a testing program aimed at developing workable solutions for this multi-faceted ...

449

Radial distribution of superthermal electrons measured with ECE (abstract)  

International Nuclear Information System (INIS)

To aid in the study of lower hybrid current drive as a means of current profile control, the radial profile and velocity distribution of the fast current-carrying electrons and their time evolution must be known. As part of the recent effort to understand this fast electron transport, a diagnostic has been installed on PBX-M to measure the electron cyclotron emission from the fast electrons. An oblique horizontal view of upshifted cyclotron emission in the midplane can give radial as well as velocity space information about the fast electrons. Emission in X mode frequencies refracted by the right-hand cutoff is radially localized. The observed emission at a specific frequency comes only from the radial region r_t_u_r_n=#0. Emission measured by this new diagnostic has been found to be radially localized as predicted. It is also expected that localized moments of the distribution function may be obtained from these data. A superheterodyne ...

0854-01-01

450

Optical diagnostics for turbulent and multiphase flows: Particle image velocimetry and photorefractive optics  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the work performed under the Sandia Laboratory Directed Research and Development (LDRD) project ``Optical Diagnostics for Turbulent and Multiphase Flows.`` Advanced optical diagnostics have been investigated and developed for flow field measurements, including capabilities for measurement in turbulent, multiphase, and heated flows. Particle Image Velocimetry (PIV) includes several techniques for measurement of instantaneous flow field velocities and associated turbulence quantities. Nonlinear photorefractive optical materials have been investigated for the possibility of measuring turbulence quantities (turbulent spectrum) more directly. The two-dimensional PIV techniques developed under this LDRD were shown to work well, and were compared with more traditional laser Doppler velocimetry (LDV). Three-dimensional PIV techniques were developed and tested, but due to several experimental difficulties were not as successful. ...

1997-01-01

451

Myocardial perfusion SPECT in patients after myocardial infarction: Comparison of "2"0"1Tl and dual-isotope protocol (rest "2"0"1Tl/stress "9"9"mTc tetrofosmin)  

International Nuclear Information System (INIS)

The diagnostic accuracy is compared of the dual-isotope protocol and the conventional "2"0"1Tl protocol, for detection of the coronary artery disease (CAD) using data on a total of 69 patients after myocardial infarction (MI). The "2"0"1Tl protocol was used to examine 44 patients, the dual-isotope protocol was used with 25 patients. All patients were examined by coronarography; a narrowing of the artery by more than 50 % was considered significant for CAD. The sensitivity, specificity and diagnostic accuracy was 97.7 %, 100 % and 97.7 % resp. for the "2"0"1Tl protocol, and 95.2 %, 75 % and 92 % resp. for the dual-isotope protocol. A higher diagnostic accuracy of the dual-isotope protocol has not been proven, and the "2"0"1Tl protocol continues to be used for examinations of patients after MI

1998-08-01

452

Measurement of dose-area product in diagnostic radiology as a method of assessing the radiation exposure. (Results, experience, proposals for improvement, recommendations relating to radiological protection). Report of an expert meeting  

International Nuclear Information System (INIS)

The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product measurement in the dosimetry activities in medical ...

453

MTX diagnostic and timing system for free-electron laser heating experiments  

International Nuclear Information System (INIS)

In the microwave tokamak experiment (MTX) program, we are concentrating on experiments using intense, free-electron laser (FEL) generated microwave pulses. In initial FEL experiments, several diagnostic instruments were operated during injection of microwave pulses with peak powers to 0.2 GW at durations of 10 ns. Fixed and spatially scanning microwave detectors and receivers and a 48-element calorimeter on the inside wall of MTX diagnosed the GW-level FEL microwave pulses. With these diagnostics, linear-wave absorption and efficiencies of transmission through the quasi-optical transport system were studied. In addition, several radially resolved measurements of plasma density, temperature, and emission were made during FEL injection and were used in the analysis of microwave absorption data. A timing system, slaved to the FEL pulse arrival time, is capable of accuracy to a few nanoseconds in order to allow measurement of heating effects on the ...

454

Lymph node staging in cervical carcinoma: Results of high resolution MRT with phased-array coil  

International Nuclear Information System (INIS)

Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T_2-weighted turbo-spin-echo (TSE) and T_1-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm"2. Lymph nodes with a diameter of #>=#8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes (#>=# 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of 24 cases MR findings were true negative (specificity 92%). Diagnostic accuracy was 91%. Conclusion: ...

455

Estimation of population doses from medical uses of radiopharmaceuticals in Japan, 1977, 2  

International Nuclear Information System (INIS)

Population doses from diagnostic and therapeutic uses of radiopharmaceuticals have been estimated on the basis of a nation wide survey data on the number of investigations and treatments used radiopharmaceuticals in the nuclear medicine and the annual amount of their activities. The gonad and marrow doses were calculated from published biokinetics data from humans, employing the MIRD method. The resultant annual genetically significant dose from diagnostic and therapeutic uses of radiopharmaceuticals was 0.36 and 0.02 mrad (3.6 and 0.2 #mu#Gy) per person, respectively, with a total 0.38 mrad (3.8 #mu#Gy) per person. The annual per Caput mean bone marrow dose was 2.3 mrad (23 #mu#Gy) for diagnosis and 0.2 mrad (2 #mu#Gy), for therapy. The resultant annual leukemia significant dose was 1.8 mrad (18 #mu#Gy) per person for diagnostic uses and 0.2 mrad (2 #mu#Gy) per person for therapeutic use, with a total of 2.0 mrad (20 ...

1979-01-01

456

Diagnostic features of intrahepatic cholangiocarcinoma according to the gross type classification  

International Nuclear Information System (INIS)

Forty resected cases of intrahepatic cholangiocarcinoma were classified into four types according to the gross appearance; type I: mass forming type (n=8), type II: mass forming with periductal infiltrating type (n=20), type III: periductal infiltrating type (n=9) and type IV: intraductal growth type (n=3). Diagnostic features of these four types were studied. Peripheral enhancement was a common angiographic feature and tumor stains were recognized in 88%, 20%, 0%, 33%, respectively. Angiography and dynamic computed tomography (D-CT) were useful in differential diagnosis with hepatocellular carcinoma. Accuracy rate in diagnosis of portal vein involvement by angiography and D-CT was 82% and 91%, respectively. MRI was more useful in tumor detection than D-CT in cases with attenuation difference, in 55% of type II and in 75% of type III. Increase of arterial involvement, biliary tract involvement and portal vein involvement, incidence of lymph nodes metastases became ...

1998-08-01

457

Achievement report for fiscal 1998. Research and development of a multi-plant maintenance system (the first year); 1998 nendo seika hokokusho. Odanteki maintenance gijutsu no kenkyu kaihatsu (dai 1 nendo)  

Energy Technology Data Exchange (ETDEWEB)

This research and development is intended to structure a network centering around a center having systematized high-level maintenance technology, by utilizing the technological infrastructure having been built in local areas, together with element technologies possessed by national and private research institutes, universities and colleges. It is also purposed to establish a new industrial system for maintenance to realize high reliability, high operation rate and low cost in plants in certain areas. The present fiscal year had the following achievements: research and development of a maintenance system, a maintenance model, a maintenance vehicle, damage estimating technology for stationary parts such as piping, an anomaly diagnostic system using acoustic emission, an anomaly diagnostic system using wear particles in lubricant, an anti-wear material using surface modification, a lubrication control system, and an anomaly ...

1999-03-01

458

A new application of MRT of the lung using ultra-shot turbo spin echo sequences (UTSE)  

International Nuclear Information System (INIS)

T_2 weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T_E=90 ms, T_R=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good quality. Compared with CT, contrast is better with MRT, offering diagnostic ...

459

Strong laser fields as a probe for fundamental physics  

CERN Document Server

Upcoming high-intensity laser systems will be able to probe the quantum-induced nonlinear regime of electrodynamics. So far unobserved QED phenomena such as the discovery of a nonlinear response of the quantum vacuum to macroscopic electromagnetic fields can become accessible. In addition, such laser systems provide for a flexible tool for investigating fundamental physics. Primary goals consist in verifying so far unobserved QED phenomena. Moreover, strong-field experiments can search for new light but weakly interacting degrees of freedom and are thus complementary to accelerator-driven experiments. I review recent developments in this field, focusing on photon experiments in strong electromagnetic fields. The interaction of particle-physics candidates with photons and external fields can be parameterized by low-energy effective actions and typically predict characteristic optical signatures. I perform first estimates of the accessible new-physics parameter space ...

2008-01-01

460

Properties of different eddy-current probes for steam generator tube testing  

Energy Technology Data Exchange (ETDEWEB)

With steam generator check testing, the numerous types of defect not only have to be detected reliably but also to be identified correctly and classified according to depth. A priori, no signals are provided by the physical eddy-current mechanism, i.e. the disturbance of an excited eddy-current field by a defect, which will allow unambiguous identification and classification of the defects. The task, therefore, consists in designing the eddy-current method in terms of measurement technology in such a way as to obtain useful detection, identification and classification by a translation of the signals as simple and as save as possible. Internal through-flow wils and internal rotating probes were examined for their suitability to fulfill this three-pronged task with steam generator inspection.

1981-01-01

461

Properties of different eddy-current probes for steam generator tube testing  

International Nuclear Information System (INIS)

With steam generator check testing, the numerous types of defect not only have to be detected reliably but also to be identified correctly and classified according to depth. A priori, no signals are provided by the physical eddy-current mechanism, i.e. the disturbance of an excited eddy-current field by a defect, which will allow unambiguous identification and classification of the defects. The task, therefore, consists in designing the eddy-current method in terms of measurement technology in such a way as to obtain useful detection, identification and classification by a translation of the signals as simple and as save as possible. Internal through-flow wils and internal rotating probes were examined for their suitability to fulfill this three-pronged task with steam generator inspection. (orig./RW).

1981-01-01

462

Metal ion complexation by ionizable crown ethers  

Energy Technology Data Exchange (ETDEWEB)

Research conducted since the last progress report includes the synthesis and characterization of twenty three novel proton-ionizable crown ether compounds. Metal ion complexation behavior of new and previously-synthesized proton-ionizable crown ether compounds has been probed by solvent extraction and transport across polymer-supported liquid membranes. The behavior of neutral polyether and proton-ionizable polyether ligands in polymeric membrane electrodes has been assessed. Studies of the use of proton-ionizable crown ethers for separation of lithium isotopes were initiated. Also, the thermodynamics of interactions between alkali metal cations and ionized crown ethers have been probed by titration calorimetry. 10 refs., 1 tab.

1989-09-01

463

Joule-Thomson cryogenic cooler with extremely high thermal stability  

Science.gov (United States)

An 80-K Joule-Thomson (J-T) cooling system designed for the Probe Infrared Laser Spectrometer (PIRLS) proposed for the Huygens Titan Probe of the Cassini Saturn orbiter mission is presented. The cryogenic cooling requirements of the PIRLS instrument are listed, and the cooler system design including details of a J-T cryostat, cold head, and dewar design is described along with the results of a thermal modeling effort and lab cooler performance testing. It is shown that by using active feedback temperature control of the cold head in combination with the self-regulating action of the J-T cryostat, a temperature stability of less than 0.1 mK/min is achieved by the cooler weighting 1.8 kg.

1991-06-01

464

Gradiometry coexperiments to the gravity probe B and step missions  

Energy Technology Data Exchange (ETDEWEB)

The Gravity Probe-B (GP-B) spacecraft, designed to test predictions of general relativity, will fly in the mid 1990s. It will carry four electrostatically suspended gyroscopes in a cryogenic environment and will have a drag-free control system to minimize disturbances on the gyroscopes. The Stanford Test of Equivalence Principle (STEP) spacecraft, to fly later, will carry a set of test masses under very similar conditions. The possibility of using differential measurements of the GP-B gyroscopes suspension forces and the STEP tests mass displacement readout to form single-axis gravity gradiometers is explored. It is shown that the noise in the suspension systems is sufficiently small in the relevant frequency range, and that enough information is collected to compensate for the spacecrafts' attitude motion. Finally, using Breakwell's flat-earth approximation, these experiments are compared to other geodesy experiments and predict the contribution ...

1990-01-01

465

From dispersion relations to spectral dimension - and back again  

CERN Document Server

The so-called spectral dimension is a scale-dependent number associated with both geometries and field theories that has recently attracted much attention, driven largely though not exclusively by investigations of causal dynamical triangulations (CDT) and Horava gravity as possible candidates for quantum gravity. We advocate the use of the spectral dimension as a probe for the kinematics of these (and other) systems in the region where spacetime curvature is small, and the manifold is flat to a good approximation. In particular, we show how to assign a spectral dimension (as a function of so-called diffusion time) to any arbitrarily specified dispersion relation. We also analyze the fundamental properties of spectral dimension using extensions of the usual Seeley-DeWitt and Feynman expansions, and by saddle point techniques. The spectral dimension turns out to be a useful, robust and powerful probe, not only of geometry, but also of ...

2011-01-01

466

Final report: technical contributions to the development of incipient fault detection/location instrumentation  

Energy Technology Data Exchange (ETDEWEB)

The transmission of electrical energy by use of underground cables is increasing. Fault location techniques have certain limitations; incipient fault detection and location would help reduce the maintenance cost of these lines as well as improve the reliability of service. The report discusses some test results related to RF-probing techniques applied to high-voltage transmission lines. The high-frequency losses and attenuation in high-voltage cables places certain ultimate limitations on RF-probing techniques for incipient fault detection. Time-domain reflectrometry methods were employed to assess the RF-transmission properties of high-voltage cables at frequencies as high as 6 GHz. Fast-Fourier-transform deconvolution was used to obtain loss measurements as a function of frequency. The loss mechanisms were identified. The measurement hardware and methods are discussed as well as analysis approach leading to the conclusions.

1986-04-01

467

Erosive radially-slotted discharge in sheet current mode  

CERN Document Server

New non-stationary non-contracted form of the erosive radially-slotted discharge as a thin round sheet with the current of the azimuth direction have been discovered, its existence beings stipulated by a radial transport-wave fluxes. Characteristic features of this discharge is self-confinement of the discharge current magnitude, corresponding decrease of the current pulse duration and occurrence of an energy and substance ejection with rather unusual properties. Measurements of kinetics of the discharge current, the plasma radiation intensity and an electrical probe signal, as well as the transmission electron microscope investigations of characteristic aerodisperse aggregates arising the erosive phase, have been carried out. The probe signal duration was about 10 times greater than that of the current; its kinetics was complicated suggesting existence in the slot of two components with fundamentally different properties and states of the ...

2001-01-01

468

Development of in-vessel reflood instrumentation at ORNL  

International Nuclear Information System (INIS)

A program under the sponsorship of the United States Nuclear Regulatory Commission was intiated at the Oak Ridge National Laboratory (ORNL) in late 1977. The program, Advanced Instrumentation for Reflood Studies (AIRS), is charged with developing instrumentation for measurement of in-vessel fluid phenomena in pressurized water reactor reflood facilities. The goal of the ORNL program is to develop techniques and systems for measuring fluid flow in-core, deentrainment in the upper plenum and liquid fallback from the upper plenum into the core. A large portion of the development at ORNL is devoted to the impedance probes for measurement of two-phase flow velocities and void fractions. Film probe development at ORNL is limited to adapting the present techniques to the environment of a reflood facility. As the development progresses on all the measurement techniques, ORNL will fabricate and supply instrument systems to the reflood facilities ...

2004-09-06

469

Development of SDT sensor based eddy current probe for detection of deep fatigue cracks in multi-layer structure  

British Library Electronic Table of Contents (United Kingdom)

The detection and characterization of deeply buried fatigue damage in thick, multi-layer airframe components pose significant technical challenges to the aviation safety community. Currently, no nondestructive evaluation technique is available to reliably detect such potential damage from the exterior of the airframe, which is highly desirable in light of inspection cost as well as avoidance of structure damage. Recent technological advances in high-sensitivity magnetic sensors, i.e., spin-dependent tunneling (SDT) sensors, make it feasible to employ electromagnetic inspection techniques for deep fatigue crack inspection. In this work, we report on the development and fabrication of a low frequency eddy current probe based on a magnetically shielded SDT pickup sensor concentrically located...

2010-01-01

470

Development and operational experience of traveling in core probe drive for flux scan of 540 MWe PHWR of Tarapur  

International Nuclear Information System (INIS)

TAPP-3 and 4 reactors use large number of Self Powered Neutron Detectors (SPNDs) for Neutronic lower measurement and control. To perform in-situ calibration of these detectors in select locations and to validate the reactor physics codes which predict flux at various points in the core, traveling in-core probes (TIP) are required. The TIP assembly consists of a miniature neutron sensitive detector. The detector is driven in and out of core using a mechanism which facilitates positioning of the detector anywhere inside a vertical tube (Central carrier tube of any of the six select Vertical Flux Units) in the core. TIP is driven through retractable feed mechanism for a stroke of 13 m. This paper describes the developmental efforts and the operational feedback of the retractable feed mechanism for the stroke of 13 m used at TAPP 3 and 4 reactor. (author)

2006-11-13

471

Density measurements of coal samples by different probe gases and their interrelation  

Energy Technology Data Exchange (ETDEWEB)

Density is useful in deducing the spatial structure of coals. In this paper, nitrogen has been used instead of the commonly employed helium, for the gas displacement pycnometer based density determination of a number of coals of Indian origin. The results show that the nitrogen-based densities are always higher than the helium-based ones. Also, empirical relationships between the helium-based and nitrogen-based coal densities have been developed by two modeling methods, namely, multi-variable regression and artificial neural networks. Although the two models have fared well, the neural network model exhibits a relatively better prediction accuracy and generalization performance than the regression model. This study thus demonstrates that nitrogen, which is cheaper and easily available, can be used gainfully as the probe gas for estimating the true density of coals. 23 refs., 1 fig., 3 tabs.

2007-07-15

472

Comparison of fluorescence in situ hybridisation using peptide nucleic acid probes, Gram stain/acridine orange leukocyte cytospin and differential time to positivity methods for detection of catheter related bloodstream infection in patients after haematopoietic stem cell transplantation  

British Library Electronic Table of Contents (United Kingdom)

Abstract In 46 febrile neutropenic patients who had undergone haematopoietic stem cell transplantation, the fluorescence in situ hybridisation using peptide nucleic acid probes (PNA FISH), Gram stain/acridine orange leukocyte cytospin (Gram/AOLC), and differential time to positivity (DTP) methods were performed for detection of catheter related bloodstream infections (CRBSIs). As compared with the DTP method (which detected 11 patients with CRBSI), the PNA FISH and the Gram/AOLC methods detected ten of 11 CRBSI patients, resulting in a sensitivity, specificity, negative predictive value and positive predictive value of 91%, 100%, 97% and 100%, respectively, for the PNA FISH method as well as for the Gram/AOLC method.

2010-01-01

473

Atom-probe field-ion microscopy investigation of CMSX-4 Ni-base superalloy laser beam welds  

Energy Technology Data Exchange (ETDEWEB)

CMSX-4 superalloy laser beam welds were investigated by transmission electron microscopy and atom probe field-ion microscopy (APFIM). The weld microstructure consisted of fine (10- to 50-nm) irregularly shaped {gamma}` precipitates (0.65 to 0.75 volume fraction) within the {gamma} matrix. APFIM compositions of the {gamma} and {gamma}` phases were found to be different from those in the base metal. Concentration profiles across the {gamma} and {gamma}` phases showed extensive variations of Cr, Co and Al concentrations as a function of distance within the {gamma} phase. Calculated lattice misfits near the {gamma}/{gamma}` interface in the welds are positive values compared to the negative values for base metal. (orig.).

1996-09-01

474

Assessing the acid properties of desilicated ZSM-5 by FTIR using CO and 2,4,6-trimethylpyridine (collidine) as molecular probes  

British Library Electronic Table of Contents (United Kingdom)

A series of desilicated ZSM-5 catalysts previously shown to have improved catalytic performance in the MTG (methanol-to-gasoline) reaction [M. Bjorgen, F. Joensen, M.S. Holm, U. Olsbye, K.-P. Lillerud, S. Svelle, Appl. Catal. A 345 (2008) 43] was subjected to thorough examination using FTIR. Clearly, defects represented by internal Si-OH sites are removed upon NaOH treatment. In a parallel manner, free Si-OH sites increase in concentration and the results point to a selective mechanism for formation of mesopores as the framework dissolution preferentially takes place at defective sites in the crystallites. The acid properties of the desilicated materials were investigated by applying CO and collidine (2,4,6-trimethylpyridine) as molecular probes. Monitoring the induced frequency shifts upo...

2009-01-01

475

A Network Coding Approach to Loss Tomography  

CERN Document Server

Network tomography aims at inferring internal network characteristics based on measurements at the edge of the network. In loss tomography, in particular, the characteristic of interest is the loss rate of individual links. There is a significant body of work dedicated to this problem using multicast and/or unicast end-to-end probes. Independently, recent advances in network coding have shown that there are several advantages from allowing intermediate nodes to process and combine, in addition to just forward, packets. In this paper, we pose the problem of loss tomography in networks that have network coding capabilities. We design a framework for estimating link loss rates, which leverages network coding capabilities and we show that it improves several aspects of tomography, including the identifiability of links, the tradeoff between estimation accuracy and bandwidth efficiency, and the complexity of probe path selection. We discuss the ...

2010-01-01

476

The tactical use of constraints and structure in diagnostic problem solving  

British Library Electronic Table of Contents (United Kingdom)

This paper presents a prescriptive account of diagnostic problem solving, or diagnosis, in quality and process control. This paper identifies a general strategy, named branch-and-prune, whose manifestations can be found in disciplines such as medical diagnosis, troubleshooting of devices, and model-based diagnosis in artificial intelligence. The work aims to offer a clear conceptualization of this strategy, based on the notions of structures for the search space, and constraints to the cause's nature.The idea is to treat the search space of candidate explanations as a tree structure, in which general and high-level causal directions are branched into more specific and detailed explanations. Constraints eliminate all but a few branches (pruning), which are explored in more detail. We enumer...

2011-01-01

477

Somatic effects in nuclear medicine and radiology  

International Nuclear Information System (INIS)

Probable risks for the occurrence of somatic effects due to diagnostic radiology and nuclear medicine are summarised. The biological background of radiation carcinogenesis and epidemiological results are discussed. At the Leiden University Medical Centre the average effective dose per examination due to diagnostic radiology and nuclear medicine amount to 0.95 and 4.4 mSv, respectively. These values correspond well with the average values of 0.82 and 3.0 mSv reported for The Netherlands as a whole. Since radiological examinations are performed at a much larger frequency than nuclear medicine the relative collective dose for the first type of examinations is higher than the latter. Risk for occurency of malignancies are at least one order of magnitude lower than the hypothetical risk due to the background radiation typical of The Netherlands.

1999-01-01

478

Plasma diagnostics by spectra from LHD and atomic data  

International Nuclear Information System (INIS)

We have observed EUV spectra from the Large Helical Device (LHD) at the National Institute for Fusion Science (NIFS). We measured spectra of impurity ions; carbon, iron, xenon, tin and tungsten ions. In some cases, the plasma evolution was stable and a steady discharge was obtained, but sometimes the plasma underwent radiation collapse and rapid cooling. For carbon and iron spectra, we studied plasma diagnostics by intensity ratios of spectral lines. For other spectra of higher Z element, xenon, tin and tungsten, we studied mainly on line identifications comparing with theoretical calculations and experimental data. Related atomic data for these researches will be also discussed. (author)

2009-04-01

479

Magnetic beam position monitor  

Energy Technology Data Exchange (ETDEWEB)

Many nondestructive beam position monitors are known. However, these devices can not be used for DC particle beam diagnostics. We investigated a method of beam diagnostics applicable for the operative control of DC high power e-beam inside closed waveguide. A design of the detector for determination of{open_quote} center of mass {close_quote} position of DC particle beam was developed. It was shown that the monitor can be used as a nondestructive method for the beam position control in resonators. Magnetic field of the particle beam outside a resonator is used. The detector consists of the steel yokes and magnetic field sensors. The sensors measure magnetic fluxes in the steel yokes fixed outside the resonator. When the particle beam changes its position, these magnetic fluxes also change. Beam displacement sensitivity of the monitor depends on the steel yoke dimensions. The detector sensitivity is equal to 1 Gauss/mm for the conditions ...

1995-12-31

480

Interaction of dioxygen with the electronic excited state of Ir(III) and Ru(II) complexes: Principles and biomedical applications  

British Library Electronic Table of Contents (United Kingdom)

Luminescent transition metal complexes are enjoying a growing interest because of their ubiquitous applications in, e.g., the fields of material science, sensors and (biomedical) diagnostics, and iridium(III) and ruthenium(II) complexes are among the best studied. Due to their long-living excited states, these complexes can have a strong interaction with dioxygen, resulting in luminescence quenching. This oxygen quenching might be regarded as an unwanted effect in luminescence imaging, but, on the other hand, it can be exploited for diagnostic and therapeutic applications as well. After a theoretical introduction concerning the dioxygen quenching mechanism and the parameters involved, in the second part of this review we focus on the possibility of tailoring this quenching by modifying sel...

2011-01-01

481

Identification and staging of bladder carcinoma  

International Nuclear Information System (INIS)

The purpose of the present study was to compare the effectiveness of MRI, CT and radioimmunoscintigraphy in the staging and detection of bladder cancers in 28 patients. We distinguish two groups: Group I included the tumour stages CIS-T_3_A and the second group the deep infiltrative tumours T_3_B-T_4. MRI was slightly superior to CT in respect of tumour staging (75% correct results as compared to 63%). No understaging occurred with MRI, whereas in 22% of the cases the stage of the tumour was underestimated using CT diagnostics. Overstaging occurred in 25% of the MRI and 15% of the CT-diagnostics, respectively. RIS cannot distinguish the tumour groups, and hence this method is useful only for the detection of the primary tumour and metastases. In 77% of cases the tumour was detected and in 15% the tumour could be safely excluded. (orig.).

482

Fundamental limits on beam stability at the advanced photon source  

International Nuclear Information System (INIS)

Orbit correction is now routinely performed at the few-micron level in the Advanced Photon Source (APS) storage ring. Three diagnostics are presently in use to measure and control both AC and DC orbit motions: broad-band turn-by-turn rf beam position monitors (BPMs), narrow-band switched heterodyne receivers, and photoemission-style x-ray beam position monitors. Each type of diagnostic has its own set of systematic error effects that place limits on the ultimate pointing stability of x-ray beams supplied to users at the APS. Limiting sources of beam motion at present are magnet power supply noise, girder vibration, and thermal timescale vacuum chamber and girder motion. This paper will investigate the present limitations on orbit correction, and will delve into the upgrades necessary to achieve true sub-micron beam stability.

1998-12-10

483

Endofibrosis of Iliac Arteries in High-Performance Athletes: Diagnostic Approach and Minimally Invasive Endovascular Treatment  

International Nuclear Information System (INIS)

The aim of this article is to report our experience in the diagnosis of two cases of iliac artery endofibrosis or arteriopathy, a rare entity occurring in high-performance athletes, presenting with intermittent claudication (right-sided in both) after maximal exercise. External iliac artery endofibrosis or arteriopathy is a likely diagnosis in competitive athletes free of cardiovascular risk factors who present with leg claudication. Arteriography and a papaverine-assisted mean pressure gradient across the iliac arteries of more than 10 mmHg is a useful diagnostic approach. Moreover, balloon angioplasty of the iliac artery in that patient, in whom a pressure gradient was detected, resulted in symptomatic relief for 2 months followed by mild symptom recurrence. Thus, although balloon angioplasty is feasible and safe, it might not be adequate to treat this entity and, thus, its value remains undefined.

2006-10-01

484

Designing engineering upgradability into magnetic resonance imagers: Impact on future costs  

Energy Technology Data Exchange (ETDEWEB)

MRI is a powerful diagnostic modality of expanding availability. Equipment and installation amount to nearly $2M per site. An important component of diagnostic efficacy is not just equipment costs but also replacement costs, which for x-ray CT amount to 14-20% of the purchase cost per year; and in the early years of that technology reached 30-50%. The authors show how design choices made during the RandD stages of MRI development have allowed them to improve system performance parameters such as data reconstruction, archiving and display speeds, computational capabilities, operator interfaces, imaging sequence flexibility and signal-to-noise levels. Over the last four years these improvements have been made at a retrofit cost well below the target of 6-7% of the purchase price per year.

1987-02-01

485

Cost minimization analysis for combinations of sampling techniques in bronchoscopy of endobronchial lesions  

British Library Electronic Table of Contents (United Kingdom)

SummaryBackground The choice of sampling techniques in bronchoscopy with sampling from a visible lesion will depend on the expected diagnostic yields and the costs of the sampling techniques. Aims The aim of this study was to determine the most economical combination of sampling techniques when approaching endobronchial visible lesions. Methods A cost minimization analysis was performed. All bronchoscopies from 2003 and 2004 at Haukeland university hospital, Bergen, Norway, were reviewed retrospectively for diagnostic yields. 162 patients with endobronchial disease were included. Potential sampling techniques used were biopsy, brushing, endobronchial needle aspiration (EBNA) and washings. Costs were estimated based on registration of equipment costs and personnel costs. Sensitivity analyse...

2009-01-01

486

Application of CaSO4:Dy (TLD-900) to diagnostic x-ray exposures  

International Nuclear Information System (INIS)

The properties of a new commercial thermoluminescent dosimeter, CaSO4:Dy without a LiF binder (TLD-900) was studied for low-exposure measurements in diagnostic radiology. The former TLD-900 had a LiF binder (herein referred to as ''TLD-900/LiF''). The principle features of this dosimeter are its high sensitivity to low-energy radiation and its relatively low fading which permits measurements down to less than 2.6 X 10(-8) C kg (0.1 mR) with an accuracy better than 20%. The characteristics, annealing procedures, light sensitivity, energy response, reproducibility, and fading, of TLD-900 are discussed and compared with TLD-900/LiF. When the precautions presented in this paper are used, the dosimeters can be used for the measurement of x-ray exposures.

487

A method of stereotaxic localization adopted for conventional and digital radiography  

International Nuclear Information System (INIS)

A method for the determination of stereotaxic coordinates in radiography, e.g. angiography, pneumoencephalography or digital vascular radiography, is described. A special localization frame containing radiopaque structures and scales defines a diagnostic coordinate system. This frame is fixed to the X-ray-table prior to the radiographic procedure and two projections are obtained at arbitrary angles to each other. The focus-film distances do not have to be fixed. The target coordinates are then determined either by a simple graphical procedure or with the use of a digitizing x-y-table, by a computer. With the computer method the films are placed on the digitizing table and the target and a few reference points are marked using a cursor. From the relative positions the computer calculates the coordinates. With the special head fixation system, coordinates of structures visualized in radiographic examinations can be transferred to various therapeutic or ...

1986-01-01

488

A comprehensive condition monitoring system for hydro-electric generating units  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a comprehensive MCM [machine condition monitoring] program and suggested system for implementation in hydroelectric generating units. The system addresses all the major subsystems which make up the generating unit. A modular design means that it could be applicable in a wide variety of situations. Different subsystems may be included or excluded from the monitoring system as required. It may be used at individual plants as a stand alone system or network wide. An advanced processing and diagnostic module is included, again for use as an integral part of the system or as a stand alone analysis tool. Examples of the system's proposed data analysis and diagnostic abilities are also described using vibration signals as would be provided by the bearing module. (Author)

1994-04-01

489

A complete census of AGN and their hosts from optical surveys?  

CERN Document Server

Large optical surveys provide an unprecedented census of galaxies in the local Universe, forming an invaluable framework into which more detailed studies of objects can be placed. But how useful are optical surveys for understanding the co-evolution of black holes and galaxies, given their limited wavelength coverage, selection criteria, and depth? In this conference paper I present work-in-progress comparing optical and mid-IR diagnostics of three "unusual" low redshift populations (luminous Seyferts, dusty Balmer-strong AGN, ULIRGs) with a set of ordinary star-forming galaxies from the SDSS. I address the questions: How well do the mid-infrared and optical diagnostics of star formation and AGN strength agree? To what extent do optical surveys allow us to include extreme, dusty, morphologically disturbed galaxies in our "complete" census of black hole-galaxy co-evolution?

2010-01-01

490

Thyroidal uptake of iodine-123 in children using a gamma camera and computer  

Energy Technology Data Exchange (ETDEWEB)

The measurement of thyroidal uptake of radioiodine using a gamma camera and computer is described. In 12 children there was good agreement with simultaneous measurements using a probe, while in a further 14 patients the uptake values were consistent with the clinical diagnosis. The technique should be especially useful for infants and small children.

1985-10-01

491

Single Atom Detection With Optical Cavities  

CERN Document Server

We present a thorough analysis of single atom detection using optical cavities. The large set of parameters that influence the signal-to-noise ratio for cavity detection is considered, with an emphasis on detunings, probe power, cavity finesse and photon detection schemes. Real device operating restrictions for single photon counting modules and standard photodiodes are included in our discussion, with heterodyne detection emerging as the clearly favourable technique, particularly for detuned detection at high power.

2008-01-01

492

Radon in soil gas survey in Curitiba (Brazil)  

International Nuclear Information System (INIS)

This work describes the radon in soil gas measurements performed during the last two years in cooperation between the Laboratory of Applied Nuclear Physics of the Federal University of Technology (UTFPR), the Nuclear Technology Development Center (CDTN) and the Institute of Radiation Protection and Dosimetry (IRD) from the Brazilian Nuclear Energy Commission (CNEN). Following previously concluded measurements of radon concentration in dwellings and the measurements of 222Rn activity in drinking water collected at artesian bores of Curitiba urban area, present step of activities has been dedicated to measurements of radon concentration in soil gas. Experimental setup was based on the Professional Radon Monitor (ALPHA GUARD) connected to specially developed for such measurements Soil Gas Probe through the air pump and filter system. After the Probe was inserted, the ground has been tamped down around the probe, to prevent air ...

2002-10-08

493

Radial distribution of bonded fission gas in mixed carbide fuel pins  

International Nuclear Information System (INIS)

The fission gas xenon bonded in bubbles, in pore, and in the lattice of mixed carbide fuels is measured by electron-probe microanalysis. Radial xenon distribution and release curves are determined and are calibrated by gas chromatography of the bonded fission gas and by burnup analysis in the respective pin sections of the irradiation experiments FR2 6A and 6C, Mol 11/K 2, and DFR 330/1. The results are correlated to the microstructure of the fuel, bonding medium, temperature, and burnup. (Auth.).

1979-01-01

494

Radial distribution functions of amorphous silicon  

Energy Technology Data Exchange (ETDEWEB)

Substantial changes in the radial distribution function of amorphous Si films have been observed in neutron-diffraction studies. The spectra indicate changes in short-range order associated with an approx.11% modification in the bond-angle distribution width. The results allow the first direct comparison of structural and vibrational Raman probes of variations in local order in thin-film amorphous solids. Good agreement is obtained between the measured bond-angle variation and that based on Raman estimates.

1989-03-15

495

Molecular characterization of the Spirometra mansonoides genome: renaturation kinetics, methylation, and hybridization to human cDNA probes.  

Science.gov (United States)

High molecular weight DNA from pleroceroid larvae of the tapeworm Spirometra mansonoides was purified from isolated nuclei by conventional techniques. The DNA so isolated has a melting temperature (Tm) of 87 degrees C and a guanine plus cytosine (G/C) content of 44%. 5-Methyl cytosine could not be detected in plerocercoid DNA by HPLC analysis of DNA hydrolysates, by radiolabeling 5'-termini of MspI digests with polynucleotide kinase, or by comparing restriction patterns generated by MspI and HpaII. Renaturation kinetics demonstrated that the genome of S. mansonoides contains repetitive as well as single copy sequences and has a genome size estimated at approx. 1.6 X 10(9) bp. Hybridization was carried out between plerocercoid DNA and cDNAs for human beta-actin, alpha-tubulin and growth hormone (hGH). Rationale for this analysis was based on known homologies among actin and tubulin genes in numerous species and on apparent similarities between hGH and a plerocercoid growth factor that ...

1990-06-21

496

Cloning of rice DNA and identification of tRNA gene clones  

Energy Technology Data Exchange (ETDEWEB)

DNA from 48 hr germinated rice embryos was cut with restriction endonuclease Bam H1 and cloned to the Bam H1 site on plasmid pBR 322. The clones containing recombinant DNA were selected by their sensitivity to tetracycline and resistance to ampicillin. Using /sup 32/P-labelled rice embryos tRNA as a probe two clones were identified to contain tRNA genes by colony hybridization.

1981-10-20