This Corrective Action Investigation Plan contains the U.S. Department of Energy, Nevada Operations Office's approach to collect the data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit (CAU) 409 under the Federal Facility Agreement and Consent Order. Corrective Action Unit 409 consists of three Corrective Action Sites (CASs): TA-53-001-TAB2, Septic Sludge Disposal Pit No.1; TA-53-002-TAB2, Septic Sludge Disposal Pit No.2; and RG-24-001-RGCR, Battery Dump Site. The Septic Sludge Disposal Pits are located near Bunker Two, close to Area 3, on the TonopahTest Range. The Battery Dump Site is located at the abandoned Cactus Repeater Station on Cactus Peak. The Cactus Repeater Station was a remote, battery-powered, signal repeater station. The two Septic Sludge Disposal Pits were suspected to be used through the late 1980s as disposal sites for sludge from septic tanks located in ...
This Corrective Action Decision Document/Closure Report (CADD/CR) has been prepared for Corrective Action Unit (CAU) 409: Other Waste Sites, TonopahTest Range (TTR), Nevada, in accordance with the Federal Facility Agreement and Consent Order. Located near Area 3 on the TTR approximately 140 miles northwest of Las Vegas, Nevada, CAU 409 is comprised of three Corrective Action Sites (CASs): CAS RG-24-001-RGCR, Battery Dump Site; CAS TA-53-001-TAB2, Septic Sludge Disposal Pit (referred to as Septic Sludge Disposal Pit No.1); CAS TA-53-002-TAB2, Septic Sludge Disposal Pit (referred to as Septic Sludge Disposal Pit No.2). This CADD/CR identifies and rationalizes the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Operations Office's (NNSA/NV's) recommendation that no corrective action is deemed necessary for CAU 409. The CADD/CR have been combined into one report based on sample data collected ...
Residual plutonium (Pu), with trace quantities of depleted uranium (DU) or weapons grade uranium (WU), exists in surficial soils at the Nevada Test Site (NTS), Nellis Air Force Range (NAFR), and the TonopahTest Range (TTR) as the result of the above-ground testing of nuclear weapons and special experiments involving the detonation of plutonium-bearing devices. The special experiments (referred to as safety shots) involving plutonium-bearing devices were conducted to study the behavior of Pu as it was being explosively compressed; ensure that the accidental detonation of the chemical explosive in a production weapon would not result in criticality; evaluate the ability of personnel to manage large-scale Pu dispersal accidents; and develop criteria for transportation and storage of nuclear weapons. These sites do not pose a health threat to either workers or the general public because they are under ...
This project seeks to produce sufficient information on the physical and chemical nature of Coolside waste to design and construct physically stable and environmentally safe landfills. Unconfined compressive strength and permeability tests are reported on samples remolded near 90, 95, and 100% of low energy, standard, and modified dry densities. Unconfined compressive strength tests were also performed on some of the samples after permeability tests were completed. Swell tests were initiated on samples from Coolside pilot plant run {number_sign}2 and on a FBC hydrated ash remolded near 95% of standard density and optimum moisture content.
While it is difficult to prove that a specific material is causing contamination in a landfill, tests have been conducted at waste-to-energy facilities that indicate that household batteries contribute significant amounts of heavy metals to both air emissions and ash residue. Hennepin County, MN, used a dual approach for developing and implementing a special household battery collection. Alternative collection methods were examined; test collections were conducted. The second phase examined operating and disposal policy issues. This report describes the results of the grant project, moving from a broad examination of the construction and content of batteries, to a description of the pilot collection programs, and ending with a discussion of variables affecting the cost and operation of a comprehensive battery collection program. Three out-of-state companies (PA, NY) were found that accept spent batteries; difficulties in ...
While it is difficult to prove that a specific material is causing contamination in a landfill, tests have been conducted at waste-to-energy facilities that indicate that household batteries contribute significant amounts of heavy metals to both air emissions and ash residue. Hennepin County, MN, used a dual approach for developing and implementing a special household battery collection. Alternative collection methods were examined; test collections were conducted. The second phase examined operating and disposal policy issues. This report describes the results of the grant project, moving from a broad examination of the construction and content of batteries, to a description of the pilot collection programs, and ending with a discussion of variables affecting the cost and operation of a comprehensive battery collection program. Three out-of-state companies (PA, NY) were found that accept spent batteries; difficulties in ...
Desiccation cracking is a common phenomenon in clay materials, which may considerably increase the hydraulic conductivity of soil. This issue is one of the main concerns in the design and construction of landfill covers, especially, in arid regions. For some highly plastic soils, permeability increases during cyclic drying and wetting are not significant, even though cracking may clearly be noticed in the soil. These cracks may self-heal during subsequent wetting and saturation processes. In the present study, large scale experimental models of various natural clayey soils with various plasticity indices were subjected to cyclic drying and wetting and hydraulic conductivity testing to better understand cracking behaviour and self-healing in fine-grained soils. The soils are candidate clay ...
This request is submitted to seek interim approval to operate a Toxic Substances Control Act (TSCA) of 1976 chemical waste landfill for the disposal of polychlorinated biphenyl (PCB) waste. Operation of a chemical waste landfill for disposal of PCB waste ...
This study aims to evaluate the economic and environmental viability of the exploitation of methane gas (CH4) - biogas - concentrated at the bottom of the mountains of waste from landfill Chapeco for power generation. The landfill receives approximately of 80 tons / day, the vast majority of domestic origin.
Two series of diffusion tests were performed to examine the degradation of dichloromethane (DCM) as it diffuses through clay. The first series showed the use of a synthetic leachate with no significant initial bacterial population diffusing through a plug of intact clay; there was an induction period of 95--135 d, during which diffusion was as expected in the absence of degradation, followed by a second stage, where degradation occurred with an apparent half-life of less than 55 d at a temperature of 24 C. The second series of tests examined the diffusion of an actual leachate from the Keele Valley Landfill (KVL) (which provided both nutrients and a source of bacteria), through a compacted clay. In these tests, the induction period was reduced to 40--60 d, after which the apparent half-life was 20 d or less at 27 C. The diffusion coefficient for DCM was approximately 8 {times} 10{sup {minus}10} m{sup ...
For purposes of assessing the dumpability of wastes, Article 1 - Ordinance on the Environmentally Responsible Landfilling of Household Wastes (AbfAblV) - of the Ordinance on the Environmentally Responsible Landfilling of Household Wastes and Biological Waste Treatment Plants defines classificaton criteria for biologically and mechanically treated wastes destined for landfilling. The practical experiences that have been gathered with these classification criteria and values were evaluated in a questionnaire-based survey. This was done in particular for the purpose of verifying and validating proposals on the methodology of respiration and fermentation tests. A general finding has been that the application and implementation of the regulations of the AbfAblV is fraught with difficulties. This is evident for one thing in the frequency of analyses and for another in the difficulty of complying with the ...
The required minimum 30-year post-closure care period for municipal solid waste (MSW) landfills can be shortened by reducing or eliminating of MSW components with long-terms effect in gas and leachate. The objectives of this study were to evaluate the relative persistence of landfill gas, leachate quantity, and selected leachate parameters using post-closure monitoring data from a case study landfill in south Florida. The relative persistence of selected decomposition byproducts in leachate were evaluated by both zero order and first order models based on monitoring data from the case study landfill. The analyses show that although gas and leachate production rates diminish very quickly, some contaminants remain in leachate as the decomposition process continues at a slower rate. For the c...
During cleanup of contaminated sites, Sandia National Laboratories, New Mexico (SNL/NM) frequently encounters soils with low-level radioactive contamination. The contamination is not uniformly distributed, but occurs within areas of clean soil. Because it is difficult to characterize heterogeneously contaminated soils in detail and to excavate such soils precisely using heavy equipment, it is common for large quantities of uncontaminated soil to be removed during excavation of contaminated sites. This practice results in the commingling and disposal of clean and contaminated material as low-level waste (LLW), or possibly low-level mixed waste (LLMW). Until recently, volume reduction of radioactively contaminated soil depended on manual screening and analysis of samples, which is a costly and impractical approach and does not uphold As Low As Reasonably Achievable (ALARA) principles. To reduce the amount of LLW and LLMW generated during the excavation process, SNL/NM is evaluating two ...
This paper reports that some regions have prepared for these days of disposal shortage with comprehensive waste plans that include a strong WTE presence. Witness Broward County, Florida's program, 12 years in planning by public and private entities, Broward is the second most populated county in the state, with 1.3 million residents and a heavy tourist population, which, together, produce 1.6 million tons of waste annually. The disposal program includes Waste Management, Inc.'s expansion of a 400-acre Central Disposal Sanitary Landfill, the county's new 588-acre landfill, composting, and curbside pickup for recyclables. And, this south Florida plan would not be complete without the two brand new combustion plants. Clean Air and Water Acts notwithstanding, the Florida Department of Environmental Regulation can induce standards stricter than the federal government's due to the sensitive South Florida ecology. ...
Kaiser Alumina and Chemical Co. impounds red mud, the byproduct of alumina production, behind levees. Kaiser recognizes that this action cannot be maintained indefinitely. Therefore, a project is in progress to produce useful products from red mud that increase the profitability of the Gramercy facility. Before products could be developed, an obstacle had to be overcome. The annual rainfall in South Louisiana prevents evaporative drying of the mud lakes. Innovative methods were applied to dry the lake mud. Two products have been developed. A daily landfill cover and an absorbant, which are marketed under the Cajunite{trademark} banner. Both products are currently being tested by potential customers at their sites. Environmental concerns were addressed during development. Extensive TCLP results show no metal leachate problems. All pilot tests and plant trials received LADEQ approval. Products that are under development ...
Eukaryotes may influence pollutant degradation processes in groundwater ecosystems by activities such as predation on bacteria and recycling of nutrients. Culture-independent community profiling and...Full Text Available
Disposal of fine-particled byproducts via injection into a capola furnace using natural gas/O{sub 2} burners is a cost-efficient alternative to landfill dumping. Tests conducted in a foundry demonstrated that dusts collected there can be injected without detriment to melt-down rate and iron quality. The replacement of FeSi pellets with FeSi dust in addition reduced the slag content, while injection of coal dust permitted a decrease in coke consumption. (orig.) [Deutsch] Die Entsorgung von feinkoernigen Reststoffen durch Einblasen in einen Kupolofen ueber Erdgas/O{sub 2}-Brenner ist eine wirtschaftliche Alternative zur Deponierung. Anhand von Versuchen in einer Giesserei konnte aufgezeigt werden, dass hier anfallende Staeube ohne nachteilige Auswirkungen auf Schmelzleistung und Eisenqualitaet einzublasen sind. Die Substitution von FeSi-Formlingen durch FeSi-Staub brachte zudem eine Reduzierung des Schlackeanteils und das Einblasen von ...
The K site near Seoul began landfilling in 1992. The landfilled wastes include municipal solid waste (66.4%), construction residues (20.4%), water and wastewater sludges (trace levels), and hazardous waste (trace levels). The water content of the municipal solid waste is very high (47.3%); as a result, the leachate level (average E.L.) of the landfill, the design value of which is 7.0 m, was measured at 10.3 m in January 1995 and is increasing. The increase of leachate level in the landfill site causes a problem with slope stability. The leachate level at each disposal stage divided by the intermediate cover layer was calculated with the HELP (Hydrologic Evaluation of Landfill Performance) model and calibrated with the data measured from February 1993 to June 1995. Also, the hydraulic conductivities of the waste layer and the intermediate cover layer in each stage were calibrated ...
This request is submitted to seek interim approval to operate a chemical waste landfill for the disposal of polychlorinated biphenyl (PCB) waste. Interim approval is requested for a period not to exceed 5 years. This request covers only the disposal of sm...
This request is submitted to seek interim approval to operate a chemical waste landfill for the disposal of polychlorinated biphenyl (PCB) wastes. This request covers only the disposal of small quantities of solid PCB wastes contained in decommissioned su...
The Mixed Waste Landfill occupies 2.6 acres in the north-central portion of Technical Area 3 at Sandia National Laboratories, Albuquerque, New Mexico. The landfill accepted low-level radioactive and mixed waste from March 1959 to December 1988. This report represents the Corrective Measures Study that has been conducted for the Mixed Waste Landfill. The purpose of the study was to identify, develop, and evaluate corrective measures alternatives and recommend the corrective measure(s) to be taken at the site. Based upon detailed evaluation and risk assessment using guidance provided by the U.S. Environmental Protection Agency and the New Mexico Environment Department, the U.S. Department of Energy and Sandia National Laboratories recommend that a vegetative soil cover be deployed as the preferred corrective measure for the Mixed Waste Landfill. The cover would be of sufficient thickness to store ...
The purpose of this paper is: (1) conduct HELP model variations in weather data, profile characteristics, and hydraulic conductivities for major rock units; (2) compare and contrast the results of simulations; (3) obtain an estimation of leakage through the landfill from the surface to the aquifer; and (4) evaluate contaminant transport to the aquifer utilizing leakage estimation. The conclusions of this paper are: (1) the HELP model is useful to assess landfill design alternatives or the performance of a pre-existing landfill; (2) model results using site-specific data incorporated into the Weather Generator (Trail 4), varied significantly from generalized runs (Trials 1-3), consequently, models that lack site-specific data should be used cautiously; and (3) data from this study suggest that there will not be significant downward percolation of leachate from the surface of the landfill cap to the ...
This paper evaluates the two well-known final waste disposal methods, incineration and landfilling. In particular we compare the social cost of two best-available technologies using a point estimate based on private and environmental cost data for the Netherlands. Not only does our comparison allow for Waste-to-Energy incineration plants but for landfills as well. The data provide support for the widespread policy preference for incineration over landfilling only if the analysis is restricted to environmental costs alone and includes savings of both energy and material recovery. Gross private costs, however, are so much higher for incineration, that landfilling is the social cost minimizing option at the margin even in a densely populated country such as the Netherlands. Furthermore, we show that our result generalizes to other European countries and probably to the USA. Implications for waste policy ...
This conference provided a forum for more than 500 delegates from industry, government universities and research centres to share their professional knowledge on research and development that affects all sectors of geotechnical engineering, applied geology and hydrogeology. Accomplishments in the geoenvironmental field were also highlighted. The geotechnical sessions were entitled: pile foundations and load testing; excavations and special foundation issues; reinforced soil and soil-structure interactions; advances in modelling, constitutive issues; advances in modelling, consolidation and other applications; advances in modelling, discrete elements and slope stability; embankments and dams; landfills and barriers; fundamental soil mechanics; soil mechanics and ground movement; GIS and remote sensing; landslides and slopes; cone penetration tests and liquefaction assessment; rock mechanics; engineering geology; ...
This conference report contains the lectures presented at the BMBF status seminar on the cooperative project ``Bodies of landfills``, which took place at Wuppertal on 25th and 26th April 1995. The cooperative project was started in autumn 1993 and studies the long-term behaviour of wastes deposited at landfills in general. Inorganic and municipal wastes are studied separately. (orig./SR) [Deutsch] Der vorliegende Tagungsband enthaelt die Vortraege des BMBF-Statusseminars zum Verbundvorhaben `Deponiekoerper` vom 25. und 26. April 1995 in Wuppertal. Das Verbundvorhaben `Deponiekoerper` wurde im Herbst 1993 begonnen und befasst sich ganz generell mit dem langfristigen Deponieverhalten von Abfaellen. Es ist unterteilt in die Untersuchung von anorganischen Abfaellen und von Siedlungsabfaellen. (orig./SR)
The energy recovery scheme at Mucking Marshes landfill site, operated by Cory Environmental Limited, has been in operation since October 1991. Using landfill gas abstracted from the site, a gas turbine generates up to 3.2 MW net electric power for export. Operation and performance of the scheme has been monitored over the period January 1995 to August 1996. Overall performance since the first use of the turbine has also been studied, and has shown reliable and profitable operation. The capital cost of the gas turbine and gas compressor plant was approximately 1.8 million. Actual gas collection wells, pipework, pumping and monitoring facilities, while essential to the scheme, are considered part of the gas control equipment needed for the landfill site. Based on a notional electricity selling price of 4p/kWh, the current annual income from exported power is 550,000. This would be substantially increased by increasing the ...
...The Political Evolution of the Landfill Tax in the UK wm-1996-03 Green Taxes, Waste Management and Political Economy 1995 ^ Top ...on civil engineering Lifecycle assessment - an overlooked opportunity Refereed Journal Articles: Green taxes, waste management and political economy Reports: Environmental cost benefit ...
In accordance with Department of Energy (DOE) Regulations surveys for wetland presence or absence were conducted in September 1996 on the DWI-1630 site (Witherspoon Landfill) located in South Knoxville, Knox County, Tennessee. The DWI-1630 site includes a closed, capped landfill area, areas of past disturbance adjacent to the capped area, and patches of hardwood forest. Wetlands were identified on the landfill cap and in a small bottomland that was formerly used for a retention pond in the southwest corner of the DWI-1630 site. The wetlands identified on the cap are man-induced, atypical situation wetlands. These areas have hydrophytic vegetation and wetland hydrology, but the soils do not have hydric characteristics. Wetland development appears to be due to a combination of the grading or subsidence of the clay landfill cap, the low permeability of the clay fill soil, and the absence of surface ...
The integrated-gasification combined-cycle (IGCC) process is an emerging technology that utilizes coal for power generation and production of chemical feedstocks. However, the process generates large amounts of solid waste, consisting of vitrified ash (slag) and some unconverted carbon. In previous projects, Praxis investigated the utilization of {open_quotes}as-generated{close_quotes} slags for a wide variety of applications in road construction, cement and concrete production, agricultural applications, and as a landfill material. From these studies, we found that it would be extremely difficult for {open_quotes}as-generated{close_quotes} slag to find large-scale acceptance in the marketplace even at no cost because the materials it could replace were abundantly available at very low cost. It was further determined that the unconverted carbon, or char, in the slag is detrimental to its utilization as sand or fine aggregate. It became apparent that a more ...
COGNIS TERRAMET{reg_sign} soil leaching and Bescorp soil washing systems have been successfully combined to remediate an ammunition test burn area at the Twin Cities Army Ammunition Plant (TCAAP), New Brighton, MN. This cleanup is the first in the country to combine these two technologies, and this approach offers a permanent remedial solution. In Fall 1993, 1,600 tons of soil were remediated with an additional 10,000+ tons treated in 1994. The cleaned soil remained on-site, and the heavy metal contaminants were removed, recovered, and recycled. Eight heavy metals were removed from the contaminated soil achieving the very stringent cleanup criteria of <175 ppm for residual lead and achieving background concentrations for seven other heavy metals (antimony, cadmium, chromium, copper, mercury, nickel, and silver). In addition, both live and spent ordnance had to be removed in the soil treatment plant to meet the cleanup criteria. No hazardous waste requiring ...
Untreated landfill leachates and wastes from metal plating and mining operations are sources of environmental contamination by heavy metals. Because of their toxicity and potential for accumulation, the discharge of heavy metals must be controlled. Standard physical and chemical treatments used to remove metals from wastes such as concentration by electro-precipitation, ion exchange, solvent extraction, evaporative recovery, and conventional precipitation, are usually expensive and produce high quantities of sludge. Biosorption is the removal of metals from aqueous solutions by microorganisms. It is called biosorption rather than bioadsorption or bioaccumulation because the mechanisms of removal are not restricted to adsorption or metabolic uptake and so the more general term is preferable and has come to be accepted. In this thesis the focus is one two microorganisms and two metals. However, the possible combinations of conditions such as pH, relative metal ...
The US Department of Enregy (DOE) Subsurface Contaminants Focus Area is developing technologies to address environmental problems associated with hazardous and radioactive contaminants in soil and groundwater that exist throughout the DOE complex, including radionuclides, heavy metals; and dense non-aqueous phase liquids (DNAPLs). More than 5,700 known DOE groundwater plumes have contaminated over 600 billion gallons of water and 200 million cubic meters of soil. Migration of these plumes threatens local and regional water sources, and in some cases has already adversely impacted off-site rsources. In addition, the Subsurface Contaminants Focus Area is responsible for supplying technologies for the remediation of numerous landfills at DOE facilities. These landfills are estimated to contain over 3 million cubic meters of radioactive and hazardous buried Technology developed within this specialty area will provide efective methods to contain ...
The potential hazard of landfill wastes was previously evaluated by examining the extraction procedures for individual waste, although various wastes were co-disposed of in actual landfills. This paper investigates the reduction of extraction-procedure toxicity by co-disposing various combinations of two wastes. When two wastes are mixed homogeneously, the extraction of heavy metals from the waste mixture is critically affected by the extract pH. Thus, co-disposal wastes will have a resultant pH between the pH values of its constituent. The lower the resultant pH, the lower the concentrations of heavy metals in the extract. When these wastes are extracted sequentially, the latter extracted waste has a stronger influence on the final concentration of heavy metals in the extract. Small-scale lysimeter experiments confirm that when heavy-metal-bearing leachates Generated from hazardous-waste lysimeters are passed through a nonhazardous-waste ...
BackgroundPolicies on waste disposal in Europe are heterogeneous and rapidly changing, with potential health implications that are largely unknown. We conducted a health impact assessment of landfilling and incineration in three European countries: Italy, Slovakia and England.MethodsA total of 49 (Italy), 2 (Slovakia), and 11 (England) incinerators were operating in 2001 while for landfills the figures were 619, 121 and 232, respectively. The study population consisted of residents living within 3 km of an incinerator and 2 km of a landfill. Excess risk estimates from epidemiological studies were used, combined with air pollution dispersion modelling for particulate matter (PM10) and nitrogen dioxide (NO2). For incinerators, we estimated attributable cancer incidence and years of life lost (YoLL), while for landfills we estimated attributable cases of congenital anomalies and low birth weight ...
Within the framework of efforts to optimize state-of-the-art waste disposal methods, this research project makes a theoretical analysis of the propagation behaviour of pollutants from landfills and waste incineration plants into the immediate vicinity of such plants. In order to judge the propagation of pollutants near the above-mentioned waste disposal facilities, a calculation program was developed within the framework of this research project which permits simulation of the propagation of such emissions in a three-dimensional space by application of an Eulerian grid model. It is capable of realistically representing fluid flow conditions and pollutant concentrations for certain points of times within the complex building patterns of such plants, for randomly chosen atmospheric conditions. (orig.)
A 1 MWe power plant using waste wood fuel is to be installed at a US Marine Corps base, which will supply all wood from a landfill site. The core energy conversion technology is a down-draft gasifier supplying approximately 150 Btu/scf gas to both spark ignition and diesel dual-fuel engine-generator sets. Features of the plant design include: (1) grinding wood fuel from a wide range of waste resources, (2) specialized screening for fines removal, (3) complete tar and other waste product control without landfill disposal, and (4) use of process heat for bulk fuel drying, gasifier air pre-heating, and wastewater evaporation.
The Davis GSR Landfill (GSR) is listed by the U.S. Environmental Protection Agency on the National Priorities List. Preliminary on-site sampling results have demonstrated volatile organic compounds in ground water and surface water. The contaminants present in groundwater at this site are trichloroethylene, ethylbenzene, toluene, chloromethane, tetrahydrofuran, 1,1,1-trichloroethane, and 1,2 dichloroethane. GSR represents a potential public health concern to area residents. However, information available on this site is not currently adequate to determine if a public health concern exists to these residents. At a minimum, future investigations of this site should include a characterization of the site and site contaminants, and a characterization of the hydrogeology of the area.
In the past shredder fluff from automobile recycling was discarded in landfills, but shrinking landfill space and the partly hazardous content of the fluff as well as its caloric value, all resulted in efforts to turn this waste problem into an energy resource. In order to produce a fuel, the inorganic compounds have to be removed. Extensive analyses and particle size measurements were made on fluff from various shredder. For optimal separation all particles are reduced to a uniform, relatively small size. In a subsequent combined screening and air classification process, successful separation into organic and inorganic fractions is achieved. The inorganic fraction is treated in a heavy media or an eddy-current separator to recover the valuable metals, while the organic fraction is now suitable for thermal processing, such as fluidized bed gasification and using the resulting carbon as a chemical reagent.
Soil gas, soil, and water were assessed for organic and inorganic constituents at the former 19th Street landfill at Fort Gordon, Georgia, from February to September 2010. Passive soil-gas samplers were analyzed to evaluate organic constituents in the hyporheic zone and flood plain of a creek and soil gas within the estimated boundaries of the former landfill. Soil and water samples were analyzed to evaluate inorganic constituents in soil samples, and organic and inorganic constituents in the surface water of a creek adjacent to the landfill, respectively. This assessment was conducted to provide environmental constituent data to Fort Gordon pursuant to requirements of the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. The passive soil-gas samplers deployed in the water-saturated hyporheic zone and flood plain of the creek adjacent to the former landfill indicated the ...
...diversion generates a host of environmental, financial, and social benefits, including conserving energy, reducing disposal costs, and reducing the burden on landfills and other waste disposal methods . Waste Diversion at EPA For many years, EPA has established waste diversion goals that exceed current federal requirements. EPA ...
This paper very briefly outlines hazardous waste management issues, including regulations, in Mongolia. Air, water, and soil pollutants are identified and placed in context with climatic, social, and economic circumstances. The primary need identified is technology for the collection and disposal of solid wastes. Municipal waste problems include rapid urbanization and lack of sanitary landfills. Industrial wastes of concern are identified from the mining and leather industries. 4 refs., 2 tabs.
This 2001 edition of the guide to UK renewable companies and equipment and service providers presents summaries of the different industry sectors covering wind power, photovoltaics, solar water heating, geothermal heat pump, hydroelectric power, marine current and wave technology, bioenergy, power generation from landfill gas, energy from waste, and cogeneration. A UK company classification listing and index is provided along with listing of UK organisations and companies and an index of advertisers.
The primary methodology that is used for disposal of municipal solid waste is the use of land fills; 80--85% of the municipal solid waste (MSW) produced in the country currently is land filled. The two other disposal alternatives used are recycling and incineration. Waste-to-energy technology (WTE) which incinerates MSW to produce electricity and/or steam is attractive in other cases since it reduces landfill volume, reduces the consumption of fossil and other fuels, and produces a revenue stream from the sale of the electricity or steam. The gaseous effluents from landfills can also be used to fuel power plants. Recycling and material separation programs can have a substantial impact on the throughput and heating value of MSW collected and thus impact WTE plant economics; the magnitude of the impact will depend upon a number of factors such as what materials and what fraction are separated and recycled, the design of the WTE plant itself (its ...
This appendix contains the alphabetically indexed bibliography for the complete group of reports on municipal waste management alternatives. The references are listed for each of the following topics: mass burn technologies, RDF technologies, fluidized-bed combustion, pyrolysis and gasification of MSW, materials recovery- recycling technologies, sanitary landfills, composting, and anaerobic digestion of MSW.
Considering the fact that more than 40% of all household wastes are organic wastes composting could be an excellent relief and complement to other waste disposal methods (e.g. combustion or direct landfills). Provided the right conditions household wastes could be composted together with sewage sludges and manures. The paper discusses the legal aspects, quantitative evaluations, conveying systems, as well as the compost utilization and marketing aspects valid for the Federal Republic of Germany.
This report presents and discusses results from Task 5 of the study ''Fate of Mercury in Synthetic Gypsum Used for Wallboard Production,'' performed at a full-scale commercial wallboard plant. Synthetic gypsum produced by wet flue gas desulfurization (FGD) systems on coal-fired power plants is commonly used in the manufacture of wallboard. The FGD process is used to control the sulfur dioxide emissions which would result in acid rain if not controlled. This practice has long benefited the environment by recycling the FGD gypsum byproduct, which is becoming available in increasing quantities, decreasing the need to landfill this material, and increasing the sustainable design of the wallboard product. However, new concerns have arisen as recent mercury control strategies developed for power plants involve the capture of mercury in FGD systems. The objective of this study is to determine whether any mercury is released into the ...
Preliminary results are presented from a field study to evaluate the relative hydrologic performance of various landfill capping technologies installed by the Los Alamos National Laboratory at Hill Air Force Base, Utah. Four cover designs (two Los Alamos capillary barrier designs, one modified EPA RCRA design, and one conventional design) were installed in large lysimeters instrumented to monitor the fate of natural precipitation between 01 January 1990 and 20 September 1993. After 45 months of study, results showed that the cover designs containing barrier layers were effective in reducing deep percolation as compared to a simple soil cap design. The RCRA cover, incorporating a clay hydraulic barrier, was the most effective of all cover designs in controlling percolation but was not 100% effective. Over 90% of all percolation and barrier lateral flow occurred during the months of February through May of each year, primarily as a result of snow melt, early spring ...
ObjectivesTo extend a set of work carried out previously at Royal Holloway, the Natural History Museum and elsewhere, and instigated, to a considerable extent, by the PI to determine~%~~%~1. whether there is any significant difference in the performance of clay minerals in the presence of leachates generated by wastes from different cultures and/or deposited in different climates;~%~~%~2. what causes some, if not all, clay minerals to aggregate after reaction with landfill Ieachate;~%~~%~3. the permeabili [continued...]DescriptionAround 1995 it was shown that that interactions between clay minerals and landfill leachate destroy the clay mineral lattice, leading to reduced liner permeability. Recent work indicates that the effect may be caused by dissolution of silica and deposition of amorphous alumina. Most work to date has been done using synthetic and natural 'British' teachates. The ...
In this study the greenhouse impact of the total Finnish forest sector was considered, which means that the estimated emissions and sink effects from exported forest products were also included. The forest biomass is and seems to be in the next decades the most important factor in the carbon balance of the total forest sector. The development alternatives of forest industries and waste management practices has still a remarkable influence on the greenhouse impact of the Finnish forest sector. The waste management practices in the future has an important influence on the emissions but the exact net greenhouse impact of the landfills is still uncertain. However, the methane emissions from existing landfills can be reduced essentially by gas recovery. Increased incineration and energy recovery of wood waste (and replacing fossil fuel use by it) is also a future alternative for reducing the greenhouse effects in the forest sector. The sequestration ...
The average American generates four pounds of solid waste per day, yet increasing constraints are being placed on the ability of municipalities to handle waste disposal. Most cities face a scarcity of acceptable landfill sites and conventional incineration and landfill methods have come under strict air, water and soil pollution standards. City administrators are being encouraged to select from a variety of proposed technologies that supplant traditional waste disposal methods, some of which offer the promise of revenues from energy and resource recovery. The problem is to select from available near-term technologies those systems that will fit into a city's long-term solid-waste management program. Broadly, waste-to-energy recovery systems now available to cities may be classified as combustion, pyrolysis, biodegradation, and mechanical front-end systems. It is important to notice that operations used for mechanical front-end systems ...
The severe health and environmental hazards posed by inadequate waste-collection systems in the rapidly growing cities of the Third World have stimulated interest in the waste-to-energy options developed in industrialized countries over the past 20 years. This economic study, the first of its kind, provides: (1) a comparative analysis of the characteristics of urban solid wastes in the United States, Europe, and developing countries; (2) basic information on the characteristics and operation of the two main types of waste-to-energy systems used in the developed world - landfill gas (LFG) systems and waste combustion systems; and (3) a preliminary assessment of the feasibility of using these systems in developing countries. The main conclusion is that present technology for the recovery and utilization of LFG appears to be suitable for developing country use, although the design of LFG projects would have to be modified to accommodate higher initial gas production ...
The reduction of emission from power plants of the public power industry inevitably leads to more and more residual products being obtained which require utilization. Traditionally, the building and building materials industry as well as, for a number of years, the gypsum industry have been the main customers processing these residual materials. To avoid having to tip them at landfills that are in short supply already, further uses are sought; so, for instance, in farming to ameliorate soil and fertilize plants. Relative to this subject, proposals are already available which are presented as lectures at the conference and discussed, together with practical knowledge and new investigation results. (BBR).
First, the problem of food packaging waste is introduced and one of the solutions, the Tetra Pak, is completely described. The article highlights the political sensitivity concerning the landfilling of packaging waste, as is done with the efforts of the Tetra Pak producer concerning the collection of used Tetra Paks and the results of these efforts. The document also informs us about the different recycling options for Tetra Paks, the qualitative prevention (using cleaner packaging), the quantitative prevention (using less packaging) and the sustainable development (using loner lasting packaging). The proposed four-step plan for a communication strategy is company-specific.
...Species - see CITES Trade of Dangerous Chemicals Transport and Environment U Urban Environment Use of natural resources V Volatile Organic Compounds W Waste Landfills Waste electrical and electronic equipment - see WEEE Waste incineration Waste legislation - reporting Waste management planning Waste oils Waste shipments Waste water - see Urban waste water Water Bathing Water Drinking water Floods Marine environment Urban waste water Water Framework Directive WEEE - Waste Electric and Electronic Equipment Wildlife ...
...it only highlights the different feedstocks used in the production of fiber-based packaging materials or fossil-fuel ones; what about the energy required to convert ...feedstock, is unacceptable in trying to quantify the overall burden a specific packaging material has on the environment. As an aside, the point ... Consequentially, it is difficult to speculate on how much packaging material a company diverts from the landfill by switching from one material to another ...without specifying what geographical region said packaging material resides in. In addition, there is a lot of interest in diverting PET thermoforms from ...
This article comments on the fact that there are only 17 energy-from-waste installations in operation in the U.S. and in this respect it lags behind other industrialized nations. Explanations for this gap include the relatively inexpensive garbage disposal as landfill, operating difficulties of some early plants and the high cost of building such facilities. There has been a recent push to build resource-recovery plants and it is believed that chemical companies will probably buy energy products from such plants. Hooker Chemical Co's new energy-from-waste plant at Niagra Falls, N.Y. is described, other companies involved in resource-recovery projects are mentioned, and it is hoped that more companies will invest in such plants.
Waste electrical and Electronic Equipment (WEEE) constitutes 4% of the municipal waste in Europe, being increased by 16-28% every five years. Nowadays, Europe produces 6,5 million tonnes of WEEE per year and currently 90% goes to landfill. WEEE waste is growing 3 times faster than municipal waste and this figure is expected to be increased up to 12 million tones by 2015. Applying a new technology to separate non-ferrous metal Waste from WEEE is the aim of this paper, by identifying multi-and hyper-spectral materials and inserting them in a recycling plant. This technology will overcome the shortcomings passed by current methods, which are unable to separate valuable materials very similar in colour, size or shape. For this reason, it is necessary to develop new algorithms able to distinguish among these materials and to face the timing requirements. (Author). 22 refs.
This paper summarizes an investigation carried out on Polish terrain occupied by Russian Federation military troops. The investigation identified natural environmental devastation, pollution, and contamination. Quantitative estimation of the devastation and its economic evaluation are provided. The results of the investigation are as follows: 406 ha have been contaminated by petrochemical products; 22.7 ha are chemically polluted; and 6,500 ha of underground water, as well as 17.5 ha of surface water, cannot be classified. On 15,300 ha the soil has been degraded, of which landfills comprise an area of 98 ha. No toxic warfare agents have been detected, nor any radioactivity levels exceeding those characteristic of the given region.
Technologies and practices that recover energy and materials from municipal solid waste present a technically and economically viable alternative to sanitary landfills and other solid waste disposal methods. However, community planners considering resource recovery should be aware of the potential environmental impacts of proposed projects. To assess these impacts, a planner should: identify the most significant types of impacts; establish boundaries beyond which impacts are not significant; characterize the environment as it would exist without the proposed project over the project's lifetime; predict the magnitude, and the distribution over time and space, of potential impacts; and relate the magnitude of predicted impacts to a scale of significance that will allow environmental values to be considered in decision-making. 24 references, 1 table.
Recently, it has become clear that the chemical circumstances under which long-term geological evolution occurs must be properly evaluated in order to develop effective remediation programs for contaminated soil, landfills, radioactive waste repositories, and carbon dioxide capture and storage. The issue of acidic leakage from excavated rock stuck was assessed using a hydro-geochemical simulator, TOUGHREACT. We concluded that in order to properly investigate the phenomenon of acidic leakage from excavated pyrite-containing rock stuck, it is important to obtain accurate information about the following factors: intensity of rainfall, unsaturated flow properties of the excavated rock stuck, specific surfaces for oxidation reaction of pyrite, the species and the quantity of other minerals contained in the rock, and secondary minerals produced. (author)
From 1991 to 1996, key studies on the reutilization, treatment, and disposal technology of hazardous wastes have been incorporated into the national plan for environmental protection science and technology. At present, the research achievements have been accomplished, have passed national approval, and have been accepted. The author of this paper, as leader of the national group for this research work, expounds the newest achievements of the studies involving four parts: (1) the reutilization technology of electroplating sludge, including the ion-exchange process for recovering the sludge and waste liquor for producing chromium tanning agent and extracting chromium and colloidal protein from tanning waste residue; on the recovery of heavy metals from the electroplating waste liquor with microbic purification; on the demonstration project of producing modified plastics from the sludge and the waste plastics; and on the demonstration of the recovery of heavy metals from waste ...
The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole system and to perform the data analysis. WAND system minimum detectable activities ...
On 7 May 2009, the Ministry of the Environment set up a working group to evaluate the possible use of biodegradable waste and other biodegradable material flows for energy production and obstacles to promoting their use in the whole production cycle. The deadline for the working group was 31 January 2010. According to its mandate, the working group had to make proposals for the measures needed to promote the energy use of biodegradable waste in order to fulfil the targets of the Government Foresight Report on Long-term Climate and Energy Policy. The working group proposes thirteen measures to be put into operation so that the investments aimed at the energy use of biodegradable waste would grow significantly from the present level. The most important measure is a full ban on depositing biodegradable waste in landfills. The working group sees that the reduction of greenhouse gas emissions from landfills should, in any case, be made more ...
Activities in British Columbia's Fraser Valley generate an estimated 3 million tones of agriculture and food wastes annually, of which 85 per cent are readily available for anaerobic digestion. The potential for energy generation from biogas through anaerobic digestion is approximately 30 MW. On-farm manure-based systems represent the most likely scenario for the development of anaerobic digestion in British Columbia in the near future. Off-farm food processing wastes may be an alternative option to large centralized industrial complexes. Odour control, pathogen reduction, improved water quality, reduced greenhouse gas emissions and reduced landfill usage are among the environmental benefits of anaerobic digestion. The economical benefits include power and heat generation, biogas upgrading, and further processing of the residues to produce compost or animal bedding. This paper described a newly developed anaerobic digestion (AD) calculator that helps users ...
The role of the unsaturated properties of sand as a drainage layer in a composite liner system for landfills is investigated. The effect of the unsaturated properties of coarse-grained soil on contaminant migration was evaluated by means of a series of simulations using a one-dimensional model of a two- and a three-layer soil liner system for advection and diffusion, respectively. The results showed that under seepage conditions, the effect of an unsaturated sand layer on the advancement of the concentration front was quite insignificant. The arrival time of the C/C{sub o} = 0.5 concentration front increased from 651 days for the case with no sand layer to approximately 951 days for the case with a 1.0-m sand layer. A steady-state flow condition was ultimately established in the sand, and this fact suggests that the capillary action might not be effective. For diffusion, the arrival time of the concentration front increased nonlinearly with a decrease in the degree ...
The Raywell Process Plants unit, which reclaims a wide range of organic solvents, including chlorinated hydrocarbons, is based on thin film evaporation and distillation rather than steam distillation, thus reducing the risk of contamination by water. Henry Balfour and Co.'s Pfaudler Solvent Recovery System gives 96% or better solvent recovery and produces a near-solid waste suitable for landfill disposal; like the Raywell system, it uses a mechanically wiped thin-film evaporator. Midland Oil Refineries uses sa Raywell thin-film evaporator for recovery of waste lubricating oils rather than the conventional sulfuric acid/clay treatment, thus avoiding formation of sulfuric acid sludge waste. The Henry Balfour Bioenergy anaerobic digestion system gives yields of fuel gas with 65-75% methane as high as 0.8 cu m/kg BOD; it achieves 95-98% BOD removal with no pH control or nutrient addition because it separates solids from liquid effluent and retains liquids for ...
Biogas, produced from anaerobic digestion of organic matter in domestic, industrial and rural wastewaters and residuals, represent an alternative and renewable source of energy, with growing use worldwide. In Brazil, high population and its spatial concentration and expressive agricultural and agricultural-industrial production indicate a substantial potential of biogas production. The results presented in this work show a potential of biogas production of almost 2 billion cubic feet a day of CH{sub 4}. Viability of biogas production and use depends substantially on project scale. Generally, biogas projects are viable from landfills and domestic wastewater treatment for populations higher than 50,000 inhabitants and swine and dairy farms with at least 5,000 and 1,000 animals, respectively. Biogas is also competitive when compared to fossil fuels used in industry and transport. Despite incentive mechanisms for biogas production and use, like Clean Development ...
A $200 million paper mill being built in Hagerstown, Md., is expected to produce 150,000 bone-dry short tons per year of de-inked, market-grade pulp for writing and printing paper. The 1st Urban Fibers facility, the largest capital project in Hagerstown's history, is slated for completion in the spring. Landegger Recycled Fiber Corp. will operate and maintain the 200,000-square-foot recycling mill and 60,000-square-foot water reclamation plant. The wastepaper recycling mill plans to minimize waste and pollution by: reclaiming 635 tons per day of 100 percent post-consumer mixed office waste from the solid waste stream; saving more than 16 million cubic feet of landfill area per year; conserving the fiber equivalent of 6,700 trees per day; using no chlorine; saving about 2,000 gallons of water and 4,000 kilowatt hours of electricity per ton of throughput, compared to virgin fiber mills; reusing treated wastewater, reducing effluent discharge by 65 percent; ...
A solution based on sludge and Olive oil mill effluent (OME) co-digestion, coupled with a management plan, has been implemented, to treat and dispose safely, the mixed residues, into the natural forest and agricultural land. The mixture of up to 25% OME to the sludge improved anaerobic degradation of phenols and fats. High density fat compounds, present in OME, enhanced aggregation, settling and acetoclastic activity of anaerobic sludge. The full scale unit, obtained by modification of a cold digester, allowed to set-up a low capital cost system. The system produced large quantity of biogas and electric energy. Anaerobic degradation of the mixture improved fertilizing properties, making feasible land application of the digested mixture. Regional plan based in Geographical Information System (GIS) selected 800 ha of adequate land area for application near the WWTP. The experience is technically and economically successful. Main incomes are provided by energy use and OME charge. Sludge ...
author.The existing management of hospital waste in Lebanon currently poses both an environmental hazard as well as a public health risk. This is due mainly to lack of legislation, information and modern treatment and disposal facilities designed for this purpose. A nation-wide questionnaire survey was conducted to asses the status of hospital waste management. The study started from October 1997 till August 1998. We found that 75% of the surveyed hospitals completely ignore their total waste quantity: 73% of hospitals surveyed practice segregation at source of infectious, pathological, sharps and pharmaceuticals; more than 40% dispose of their hospital risk wastes through the municipality waste disposal, 24% by burning in open fires, 14% by on-site hospital incinerators, 11% in on-site dumping, 8% handled by a private contractor and 1% in uncontrolled landfill. We conclude that with some exceptions, the hospital waste management situation in Lebanon is very far ...
The work reported is to evaluate two alternative resource recovery systems which would produce a fuel or an energy product (steam) for sale to an industrial plant. The first alternative is a refuse derived fuel (RDF) production facility which would process waste to produce fuel for sale to the plant. The RDF would be co-fired with coal in new boilers. The second alternative is a mass burn steam generation facility which would produce high pressure superheated steam for sale. The steam would be used by the plant to cogenerate electricity and for the process. Conceptual designs are developed for each alternative to form the basis of estimates of capital and operating costs and potential energy revenues. Operating requirements are developed for both alternatives. An assessment is made of the impact of both alternatives on the environment, and it is concluded that the impact of either alternative will be negligible. Order of magnitude estimates are made of capital and operating costs. The ...
An economic analysis of the potential advantages of alternatives for recycling and reusing equipment now stored in Building 865 at the Rocky Flats Plant (RFP) in Colorado has been conducted. The inventory considered in this analysis consists primarily of metallurgical and process equipment used before January 1992, during development and production of nuclear weapons components at the site. The economic analysis consists of a thorough building inventory and cost comparisons for four equipment dispositions alternatives. The first is a baseline option of disposal at a Low Level Waste (LLW) landfill. The three alternatives investigated are metal recycling, reuse with the government sector, and release for unrestricted use. This report provides item-by-item estimates of value, disposal cost, and decontamination cost. The economic evaluation methods documented here, the simple cost comparisons presented, and the data provided as a supplement, should provide a foundation ...
This study examined the atmospheric pollution created by some waste treatment and disposal facilities in the State of Kuwait. Air monitoring was conducted in a municipal wastewater treatment plant, an industrial wastewater treatment plant established in a petroleum refinery, and at a landfill site used for disposal of solid wastes. Such plants were selected as models for waste treatment and disposal facilities in the Arabian Gulf region and elsewhere. Air measurements were made over a period of 6 months and included levels of gaseous emissions as well as concentrations of volatile organic compounds (VOCs). Samples of gas and bioaerosols were collected from ambient air surrounding the treatment facilities. The results obtained from this study have indicated the presence of VOCs and other gaseous pollutants such as methane, ammonia, and hydrogen sulphide in air surrounding the waste treatment and disposal facilities. In some cases the levels exceeded the ...
Limestone-based sorbents are used extensively in utility boilers and tail-gas desulfurization units to remove sulfur oxides formed during the combustion of fossil fuels. Such units generate {approximately}20 million tons of flue-gas desulfurization (FGD) wastes in the U.S. annually, the bulk of which ({approximately}95%) are discarded in landfills or holding ponds. However, a significant portion of the Ca in these materials is not sulfated (remains as CaO or Ca(OH){sub 2}), particularly in units that generate dry wastes. When hydrated, such wastes exhibit a strong affinity to absorb acid gases at ambient temperature. This study represents a continuation of previously reported CO{sub 2}-absorption studies and includes more recent work on the absorption of H{sub 2}S and NO. Ten FGD-waste samples along with a control fly ash were examined. Absorption capacities, the role of available calcium and particle size, and mineralogic changes in the wastes following exposure ...
The procedure describes the procedures to be used in evaluating consumable and combustible cartridge cases. Included are ballistic tests, environmental tests, adverse condition tests, fungus resistance tests, drop tests and safety tests. (Author)
The author describes the results of post-test analyses of PANDA transient (M-series) tests M2 and M3. The purpose of the PANDA post-test analysis activity is to demonstrate that TRACG is applicable for the calculation of long-term SBWR containment response to a LOCA. Comparisons between TRACG predictions and test measurements are presented and discussed in the dual context of what the test results show and the capability of TRACG to predict their key features
The results of tests performed on the FMC Fresnel-Belt Solar Collector at the Midtemperature Solar Systems Test Facility are summarized. Tests were conducted over a temperature range from 100 to 250/sup 0/C. Test objectives are defined, test procedures are described, and test results and conclusions are given.
Two accelerated aging test procedures are proposed for use on solid dielectric extruded distribution cables under wet conditions. One test method is a fixed time duration test in which the degree of cable specimen aging is assessed in terms of breakdown tests, while the other test method is a time to breakdown test in which the cable specimens are voltage stressed until failure ensues.
The foils of various materials were irradiated with "6"0Co with an activity of 11,538 TBq. The minimum radiation dose was 25 kGy. Changes in chemico-physical properties were evaluated by infrared spectroscopy and were not detected after irradiation with 25 kGy. Packing foils were subjected to the following tests: mechanical tests, tests of weld strength, tests of impact resistance, free fall tests, permeability tests for water vapour and microbiological tests. The results of all tests were tabulated. The tests showed that the foils are impermeable for microorganisms and provided the welds are airtight the packed products remain sterile. (J.P.).
Large volumes of woodwaste disposal by incineration in a number of wigwam burners are contributing to pollution problems in Williams Lake, British Columbia. In 1985, the latest year for which data are available, total woodwaste production was about 800 million bd ft equivalent; only about 14% of this was used for energy recovery. In addition, about 66,000 m/sup 3/ of waste was sent to landfills after open burning. The characteristics of the local woodwaste are summarized, and available conversion technologies and the potential application of their products are reviewed. These include direct combustion, pyrolysis, gasification, liquefaction, and densification, for use in power generation, cogeneration, and the manufacture of saleable products. Environmental and legal aspects of woodwaste utilization are also outlined. Finally, options for reducing pollution from existing burners are reviewed. One option is the upgrading of existing burners; however, it is noted that ...
The VerTech Pit Method for wet oxidation of municipal sewage sludge offers an ecologically and economically advantageous alternative for dealing with sewage and special sludges. Europe`s first commercial plant has now been commissioned in Apeldoorn in the Netherlands following industrial-scale trials in the USA. Up to its present stage of operation the plant has achieved a high degree of reduction of solid residues and a favourable resource and environmental profile, thus impressively confirming earlier results. It is amply in keeping with the landfill criteria laid down in the Household Waste Technical Code. Furthermore, the potential sludge throughput has been found to exceed the projected value. [Deutsch] Mit dem VerTech-Tiefschachtverfahren zur Nassoxidation kommunaler Klaerschlaemme steht ein alternatives Verfahren zur Behandlung von Klaer- und Sonderschlaemmen zur Verfuegung, das oekologische und wirtschaftliche Vorteile aufweist. Nach grosstechnischer ...
The generation of industrial solid wastes containing leachable species of environmental concern is a problem for developing and developed nations alike. These materials arise from direct processing of mineral ores, from production of metals and minerals, from manufacturing operations, and from air and water pollution treatment processes. The general characteristics that make these wastes intractable is that their content of hazardous species is not easily liberated from the waste yet is not bound so tightly that they are safe for landfill disposal or industrial use. The approach taken in this work is a thermal treatment that separates the inorganic contaminants from the wastes. The objective is to provide recovery and reuse of both the residual solids and liberated contaminants. The results from operating this technique using two very different types of waste are described. The reasons that the process will work for a wide variety of wastes are explored. By using ...
Pollutants resulting from the management of solid waste have been shown to affect the air, land, oceans, and waterways. In addition, solid wastes have other, more indirect impacts such as reduction in feedstocks of natural resources, because useful materials are disposed of rather than recycled. The objective of this study is to evaluate solid waste management practices that have negative implications on the global environment and develop recommendations for reducing such impacts. Recommendations identifying needed changes are identified that will reduce global impacts of solid waste practices in the future. The scope of this study includes the range of non-hazardous solid wastes produced within our society, including municipal solid waste (MSW) and industrial solid waste (ISW), as well as industry-specific wastes from activities such as construction, demolition, and landclearing. Most solid waste management decisions continue to be made and implemented at very local levels, ...
Carbonyl compounds constitute an important reactive class of non methane volatile organic compounds. They can be emitted directly to the atmosphere from primary sources such as combustion engines, landfills and wastewater surfaces or as secondary products by the photochemical oxidation of hydrocarbons and other volatile organic compounds 1-3. Carbonyls photo-oxidize during the day to produce toxic radicals such as OH, HO_2, RO and RO_2. These species react with nitrogen oxides (NOx) and other VOCs present in the atmosphere to form tropospheric ozone (O_3); a highly reactive oxidizing agent that is harmful to human health, agricultural products and climate 4, 5. Hence identifying the levels and sources of ozone precursors such as low carbonyls, carbon monoxide (CO) and NOx derivatives, and understanding their physical and chemical transformation in the troposphere is an important task due to their atmospheric and adverse health implications. Diurnal variations of ...
Full text.This study focuses on the management of municipal solid waste (MSW) in Lebanon. It addresses the current status of MSW management in Lebanon in terms of collection, transport and disposal, infers the associated impacts of such practices and discusses mitigation measures and finally proposes basic guidelines for a national strategy for solid waste management in the country. The study is based on available previous investigations and on a field survey of 113 villages in four different countries. The study revealed the absence of an effective environmental policy and poor collection and disposal methods throughout the country, except for the Greater Beirut Area (G A), where better solid waste management practices are employed. Although collection of MSW outside GBA was found to be acceptable by local authorities, resources (labor and equipment) were not used efficiently. Furthermore, treatment of collected waste is almost not available. Waste collected is invariably open dumped ...
Presently, Nigeria is one of the fastest growing Telecom markets in the world. The country's teledensity increased from a mere 0.4 in 1999 to 10 in 2005 following the liberalization of the Telecom sector in 2001. More than 25 million new digital mobile lines have been connected by June 2006. Large quantities of mobile phones and accessories including secondhand and remanufactured products are being imported to meet the pent-up demand. This improvement in mobile telecom services resulted in the preference of mobile telecom services to fixed lines. Consequently, the contribution of fixed lines decreased from about 95% in year 2000 to less than 10% in March 2005. This phenomenal progress in information technology has resulted in the generation of large quantities of electronic waste (e-waste) in the country. Abandoned fixed line telephone sets estimated at 120,000 units are either disposed or stockpiled. Increasing quantities of waste mobile phones estimated at 8 million units by 2007, ...
The proposed action is to recycle slightly activated copper that is currently stored in a warehouse leased by Lawrence Berkeley Laboratory (LBL) to a scrap metal dealer. Subsequent reutilization of the copper would be unrestricted. This document addresses the potential environmental effects of recycling and reutilizing the activated copper. In addition, the potential environmental effects of possible future uses by the dealer are addressed. Direct environmental effects from the proposed action are assessed, such as air emissions from reprocessing the activated copper, as well as indirect beneficial effects, such as averting air emissions that would result from mining and smelting an equivalent quantity of copper ore. Evaluation of the human health impacts of the proposed action focuses on the pertinent issues of radiological doses and protection of workers and the public. Five alternatives to the proposed action are considered, and their associated potential impacts are addressed. The ...
The Department of Energy (DOE), Western Area Power Administration (Western) proposes to consolidate segments of two transmission lines near the Gering Substation in Gering, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska, within the city of Gering. Presently, there are three parallel 115-kilovolt (kV) transmission lines on separate rights-of-way (ROW) that terminate at the Gering Substation. The project would include dismantling the Archer-Gering wood-pole transmission line and rebuilding the remaining two lines on single-pole steel double circuit structures. The project would consolidate the Gering-Stegall North and Gering-Stegall South 115-kV transmission lines on to one ROW for a 1.33-mile segment between the Gering Substation and a point west of the Gering Landfill. All existing wood-pole H-frame structures would be removed, and the Gering-Stegall North ...
The Department of Energy (DOE), Western Area Power Administration (Western) proposes to consolidate segments of two transmission lines near the Gering Substation in Gering, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska, within the city of Gering. Presently, there are three parallel 115-kilovolt (kV) transmission lines on separate rights-of-way (ROW) that terminate at the Gering Substation. The project would include dismantling the Archer-Gering wood-pole transmission line and rebuilding the remaining two lines on single-pole steel double circuit structures. The project would consolidate the Gering-Stegall North and Gering-Stegall South 115-kV transmission lines on to one ROW for a 1.33-mile segment between the Gering Substation and a point west of the Gering Landfill. All existing wood-pole H-frame structures would be removed, and the Gering-Stegall North ...
In June 1997, the US Navy plans to close its Naval Air Facility on Sand Island and transfer the atoll to the US Fish and Wildlife Service for use as a National Wildlife Refuge. Midway provides breeding and feeding habitat for migratory seabirds, terrestrial and marine mammals, sea turtles and other reptiles, and a variety of reef fishes and invertebrates. As part of the base closure and transfer process, 36 sites of potential environmental concern were identified on Sand and Eastern islands. These sites include landfills and uncontrolled disposal areas, hazardous materials storage areas, abandoned transformers, sewer outfalls, and other potential hazardous waste sites. Potential contaminants include pesticides, PAHs, PCBs, and heavy metals. A screening ecological risk assessment was performed at each site with a goal of determining whether contaminants could pose any current or future risks to protected migratory bird or marine mammal wildlife species. Specific ...
This report documents the development and use of the Greenhouse Gases, Regulated Emissions, and Energy Use in Transportation (GREET) model. The model, developed in a spreadsheet format, estimates the full fuel- cycle emissions and energy use associated with various transportation fuels for light-duty vehicles. The model calculates fuel-cycle emissions of five criteria pollutants (volatile organic compounds, carbon monoxide, nitrogen oxides, sulfur oxides, and particulate matter measuring 10 microns or less) and three greenhouse gases (carbon dioxide, methane, and nitrous oxide). The model also calculates the total fuel-cycle energy consumption, fossil fuel consumption, and petroleum consumption using various transportation fuels. The GREET model includes 17 fuel cycles: petroleum to conventional gasoline, reformulated gasoline, clean diesel, liquefied petroleum gas, and electricity via residual oil; natural gas to compressed natural gas, liquefied petroleum gas, methanol, hydrogen, and ...
Performance testing and ...Performance testing and commissioning In either an Authority-owned or a dedicated MRF, the Contracting Authority should ...Performance testing is done to demonstrate that the contractor is able to meet the guarantees given
Task, Psychomotor Vigilance Test (PVT) Transition to Operations ... Related Tasks (36). Task, Psychomotor Vigilance Test (PVT) on ISS. Common Item(s) ...
... Construction, Geology, and Aquifer Testing of the Maalo ... 8-98) Prescribed by ANSI Std Z39-18 Page 3. Construction, Geology, and Aquifer Testing ...
This paper describes a radiation shield verification survey of a large hot cell at the Fast Flux Test Facility (FFTF). The following aspects of the shield test are discussed: description of the FFTF; description of the hot cell; the test procedures; radiation protection, and the test results.
The object of the test was to develop a method to field test the Exploding Bridgewire (EBW) System for proper functioning prior to use. Two basic designs were conceived and tested. The first design using a two element spark gap and a calibrated fuse link ...
IntroductionChest pain with ST-segment elevation is a rare clinical problem during dobutamine stress testing. Although beta-agonists treatment prior to dobutamine stress testing...Full Text Available
... Search Help? Coping with Test Pain, Discomfort, and Anxiety Introduction | Be Prepared | Know Your Tests | Relax | Conclusion ... though they may feel some embarrassment, discomfort, or anxiety at the outset. If undergoing medical tests makes ...
This Test Plan outlines the testing to be done on the Special Protective Coating (SPC) Polyurea which includes: Tank Waste Compatibility, Decontamination Factor Testing, and Adhesion Strength Testing after a sample has been exposed to Radiation.
While the methodology used in developing test items can vary significantly, to ensure quality examinations, test items should be developed systematically. Test design and development is discussed in the DOE Guide to Good Practices for Design, Development, and Implementation of Examinations. This guide is intended to be a supplement by providing more detailed guidance on the development of specific test items. This guide addresses the development of written examination test items primarily. However, many of the concepts also apply to oral examinations, both in the classroom and on the job. This guide is intended to be used as guidance for the classroom and laboratory instructor or curriculum developer responsible for the construction of individual test items. This document focuses on written test items, but includes information relative to ...
A part of the waste materials arising in iron and steel manufacture is utilised physically, either internally for the recovery of iron or externally for the production of cement and nonferrous metals. Most of these materials can be used without prior processing. Iron and steel-relevant waste materials which at present are still landfilled or disposed of as hazardous wastes are not immediately suitable for physical recycling as secondary raw material. These waste materials have to be processed without exception before they can be used again in the existing steel and iron manufacturing plants. The results of the authors` own studies have clearly shown that the cupola furnace is suited for the use of a wide variety of waste materials. [Deutsch] Ein Teil der bei der Eisen- und Stahlerzeugung anfallenden Abfallstoffe werden entweder intern zur Rueckgewinnung des Eisens oder extern in der Zement- bzw. Nichteisenmetallgewinnung stofflich verwertet. Dabei handelt es sich ...
Biomass is one of the main natural resources in Sweden. The present low-CO{sub 2} emission characteristics of the Swedish electricity production system (hydro and nuclear) can be retained only by expansion of biofuel applications for energy purposes. Domestic Swedish biomass resources are vast and renewable, but not infinite. They must be utilized as efficiently as possible, in order to make sure that they meet the conditions for sustainability in the future. Application of efficient power generation cycles at low costs is essential for meeting this challenge. This applies also to municipal solid waste incineration with energy extraction, which should be preferred to its dumping in landfills. Hybrid dual-fuel combined cycle units are a simple and affordable way to increase the electric efficiency of biofuel energy utilization, without big investments, uncertainties or loss of reliability arising from complicated technologies. Configurations of such power cycles are ...
Upon request by the Science and Technology Agency of Japanese Government, the Japan Atomic Energy Research Institute has conducted Piping Reliability Test Program to demonstrate the safety and reliability of light water reactor primary pipings. In this report, the results of the program are summarized. In the test program, pipe fatigue tests, Leak-Before-Break (LBB) verification tests and pipe rupture tests were carried out to examine the integrity of pipings, to verify the LBB concept and to demonstrate the effectiveness of the protective measures against jet impingement and pipe whip under pipe rupture event, respectively. In the pipe fatigue tests, a procedure to predict the fatigue crack growth was developed and the integrity of piping during plant service life was demonstrated. In the LBB verification tests, pipe fracture ...
The Fast Flux Test Facility (FFTF) reactor, which started operating in 1982, is a 400 MWt sodium-cooled fast neutron reactor located in Hanford, Washington State, and operated by Westinghouse Hanford Co. under contract with U.S. Department of Energy. The reactor has a wide variety of functions for irradiation tests and special tests, and its major purpose is the irradiation of fuel and material for liquid metal reactor, nuclear reactor and space reactor projects. The review first describes major technical specifications and current conditions of the FFTF reactor. Then the plan for irradiation testing is outlined focusing on general features, fuel pin/assembly irradiation tests, and absorber irradiation tests. Assemblies for special tests include the material open test assembly (MOTA), fuel open test ...
The Fast Flux Test Facility (FFTF) reactor, which started operating in 1982, is a 400 MWt sodium-cooled fast neutron reactor located in Hanford, Washington State, and operated by Westinghouse Hanford Co. under contract with U.S. Department of Energy. The reactor has a wide variety of functions for irradiation tests and special tests, and its major purpose is the irradiation of fuel and material for liquid metal reactor, nuclear reactor and space reactor projects. The review first describes major technical specifications and current conditions of the FFTF reactor. Then the plan for irradiation testing is outlined focusing on general features, fuel pin/assembly irradiation tests, and absorber irradiation tests. Assemblies for special tests include the material open test assembly (MOTA), fuel open test ...
Improved test techniques are needed for evaluating the inherent stability of middle distillate fuels both in surveillance and in procurement activities. A project was initiated to define and evaluate the contributing conditions leading to the formation of deleterious products in accelerated aging tests of middle distillate fuels and to relate these results to an experimental definition of more repeatable/reliable middle distillate fuel stability test technique(s). A literature search was conducted to provide a list of stability test techniques and their interpretations which could be used in a correlative middle distillate fuel stability test program. For this program, seven accelerated stability tests were chosen and evaluated using a set of six test fuels. The test techniques were selected to represent a wide variety ...
The PANDA test facility at PSI in Switzerland is used to study the long-term Simplified Boiling Water Reactor (SBWRT) Passive Containment Cooling System (PCCS) performance. The PANDA tests demonstrate performance on a larger scale than previous tests and examine the effects of any non-uniform spatial distributions of steam and noncondensables in the system. The PANDA facility is in 1:1 vertical scale, and 1:25 'system' scale (volume, power, etc.). Steady-state PCCS condenser performance tests and extensive facility characterization tests have already been conducted. A series of transient system behavior tests have been completed by end of 1995. Results from the first three transient tests (M3 series) are reviewed. The first PANDA tests exhibited reproducibility, and indicated that the SBWR containment is likely to be ...
The PANDA test facility at the Paul Scherrer Institute is used to study the long-term performance of the Simplified Boiling Water Reactor's passive containment cooling system. The PANDA tests demonstrate performance on a larger scale than previous tests and examine the effects of any non-uniform spatial distributions of steam and non-condensable gases in the system. The facility is in 1:1 vertical scale and 1:25 scale for volume, power etc. Extensive facility characterization tests and steady-state passive containment condenser performance tests are presented. The results of the base case test of a series of transient system behaviour tests are reviewed. The first PANDA tests exhibited reproducibility, and indicated that the Simplified Boiling Water Reactor's containment is likely to be favorably responsive and highly ...
This paper presents the test results of a research program to investigate the performance of polymeric insulators for 15-kV dead-end applications on distribution systems. The test program involved both new insulators from five different manufacturers and naturally-aged insulators removed from service on the distribution system of Pennsylvania Power and Light. The test series to evaluate the new insulators included: preconditioning treatments, salt fog and tracking wheel accelerated aging tests, electrical tests, and material and physical tests. The tests for the naturally-aged insulators were mainly limited to the electrical tests and the material and physical tests.
This paper describes the dielectric and accelerated aging tests on prototype {plus minus}500 kV dc oil-filled self-contained cables. The extensive test program was required to evaluate the High-Voltage cables for the St. Lawrence river crossing of the {plus minus}500 kV Quebec-New England HVDC power transmission system. The paper relates the main elements of the test program. It describes the required insulation levels, the characteristics of the cables supplied by three different manufacturers, as well as the cables' installation for the type tests and accelerated aging tests. Details of the test program and procedures followed to carry out the tests are given. Findings of the tests are also reported.
The author gives an account of tests with the X-phone system. The aim of the tests was to establish the reliability and behaviour of the apparatus mounted on a winning machine and to investigate the possibility of setting up a radio link, without laying an extra wire, between the foot of the tubbing-lined roadway and the winning machine on a steep face. The author describes the face and the test conditions and presents details of the satisfactory test results.
Four unique deisgn features are described which make the Fast Flux Test Facility eminently suitable for irradiation test programs. These features are a fast flux level of 7 x 10"1"5 neutrons/cm"2/sec, a 36-inch reference (breeder reactor) core height, test volumes suitable for testing of statistical quantities of materials, and the capability for direct (contact) or indirect (proximity) instrumentation of active core experiments.
The Fast Flux Test Facility (FFTF) will provide a prototypic test environment for advanced fuels and materials development within the U. S. LMFBR program. As a fast test reactor, the FFTF also provides a potentially unique capability for conduct of safety experimentation relevant to selected LMFBR safety issues associated with postulated core disruption events. The utility and feasibility of possible extension of FFTF testing into the area of safety research is being investigated. 5 fig.
The author discusses the accelerated aging tests performed using Hondo and Maya as aging resids with a commercial large pore hydrotreating catalyst. The results from these tests were compared with those obtained under a normal full life test. The test resid was a sample of a typical refinery charge and the activities for sulfur and vanadium removal were determined at 720"0F after successive brief periods of exposure to the heavier oils.
Abstract: The clustered logrank test is a nonparametric method of significance testing for correlated survival data. Examples of its application include cluster randomized trials where groups of patients rather than individuals are randomized to either a treatment or a control intervention. We describe a SAS macro that implements the 2-sample clustered logrank test for data where the entire cluster is randomized to the same treatment group. We discuss the theory and applications behind this test as well as details of the SAS code.
A limited program of field measurements was undertaken in order to define the wind characteristics of the DOE/Sandia vertical axis wind turbine test facility. Because micrometeorological conditions under which a particular wind turbine is tested may have ...
Thin film solar cells and solar cell testing - photovoltaic cells, radiation damage to cadmium sulfide solar cells, and airplane testing of solar cells
This paper defines a rigorous seal test program conducted to develop a functional and proven high-pressure, multi-product swivel suitable for use as a Floating Production Storage and Offloading (FPSO) unit for the transfer of liquids and gases at high pressures and high temperatures through a rotating system. The test program was accomplished with specially designed test equipment with computer monitoring of temperature, torque, fluid pressures, seal lip temperatures, number of cycles, and leakage. The three primary phases are: (A) Seal Laterial screening with a computer-automated Falex testing machine, plus physical testing of chemically exposed samples. (B) One-third scale testing of several seal system configurations using a hydraulic driven, computer controlled test machine. (C) Full scale testing of prototype ...
The blood beryllium lymphocyte proliferation test (BeLPT) is a modification of the standard lymphocyte proliferation test that is used to identify persons who may have chronic beryllium disease. A major...Full Text Available
This 1978 annual report contains the results of ''Seismic testing of Wolsung-1 steam generator model'' which was initiated in 1977 as a part of a study on nuclear components testing. Model 78, improved version of Model 77 which did not take into account f...
This report is the final report on the seismic testing of reactor components conducted since 1977 with opening of the vibration laboratory at KAERI. In 1979, forced vibration testing of Wolsung-1 steam generator model using sine dwell and white nosie rand...
A single radial hemolysis test was developed for quantitation of specific antibody to non-hemagglutinating viruses. With the human coronaviruses as models, this test utilizes the binding properties...Full Text Available
Various methods to analyse the effect of a non-isotherme water injection on the pressure evolution during a test on a double geothermal well are investigated. Then, several types of injection test are simulated with experimental data to examine the condit...
The proper selection of materials of construction is necessary to provide process equipment with optimum performance and corrosion resistance. If properly chosen, the selected material should deteriorate at a uniform, predictable rate, which will allow for maintenance or replacement at scheduled intervals. This concept of risk assessment for predictive maintenance is a minimum requirement for proper materials selection. Materials selection is based on prior service history, field corrosion tests, pilot-plant tests, and laboratory bench-top tests--in that relative order of usefulness. Corrosion test methods are usually divided into two groups: laboratory and field (plant-site) tests. The main difference between the two is that field test specimens are exposed to actual process conditions will all of the variables involved, while laboratory ...
Corrosion test, as a material selection test method of nozzle to be used in the marine diesel engine, was adopted and discussed. Due to the heightening in output power and lengthening in stroke of the marine diesel engine, the fuel injection nozzle became so severe in working condition that the nozzle tip became in lift 1/6 to 1/18 time as long as that of short stroke type in past. Then upon investigating cause of damage, the damage was confirmed to be mainly caused by the high temperature sulfidization corrosion. Then by preparing 20 kinds of candidate test piece and making sulfidization corrosion test in accordance with the high temperature corrosion test procedure, corrosiveness was evaluated through change in weight between before and after testing. As a result of testing, three kinds of test piece, inclusive of high ...
The stand is designed to test supports of development workings. To expand the test range for various types of supports, the cross pieces have fixing devices in the form of winches interacting by cables through blocks fastened to the stand body with the support hinges.
In the past decade in vitro tests have been developed that represent a range of anatomic structure from perfused whole organs to subcellular fractions. To assess the use of in vitro tests for toxicity...Full Text Available
This document reports the results of testing of spent ion exchange media pretreatment technologies. Emphasis of the testing activities has been on screening pretreatment technologies, such as drying and emulsification, which are compatible with vitrification, cementation, and incineration. Ion exchange media tested for cementation and incineration pretreatment technologies were typical organic ion exchange resins and inorganic zeolites. The ion exchange medium tested for vitrification pretreatment technologies was inorganic zeolite. The results of testing activities are discussed in detail in this report.
This report provides test results on the thermal performance of an Owens-Illinois Sunpak liquid, evacuated tube, solar collector under simulated conditions. The test was conducted using the Marshall Space Flight Center Solar Simulator in accordance with the test requirements specified in ASHRAE 93-77 (Method of Testing to Determine the Thermal Performance of Solar Collectors) and the procedures contained in MTCP-FA-SHAC-400 (Procedure for Operation of the MSFC Solar Simulator Facility). The tests were performed on a module used on the early demonstration projects. A current production module is undergoing tests with results to be in a subsequent report.
The multi-frequency binary sequence experimental technique has been implemented at the Fast Flux Test Facility for routine surveillance activities. The frequency content of the standard rod-movement sequence has been shown to be sufficient to normalize the data at moderate frequencies. This obviates the need for auxiliary calibration measurements and provides the reactivity worth of the test control rod. Analyses of a series of tests conducted in 1986 illustrate that the rod worths inferred from the tests are consistent with zero-power measurements. Also, the dependence of the prompt feedback time constant on reactor conditions was determined.
Epoxy-resin based neutron shielding material, NS-4-FR, is used for spent fuel transport and/or storage cask. In this paper the outline of thermal aging test performed to evaluate the heating effect on this neutron shielding material, NS-4-FR, is introduced. The test is consisted of two kinds of thermal aging test, one is 'Basic Test' and the other is 'Block Heating Test'. The former is cooperatively performed by ten Japanese Electrical Power Companies, and the latter is done by GESC and NOF Corporation. (authors)
Epoxy-resin based neutron shielding material, NS-4-FR, is used for spent fuel transport and/or storage cask. In this paper the outline of thermal aging test performed to evaluate the heating effect on this neutron shielding material, NS-4-FR, is introduced. The test is consisted of two kinds of thermal aging test, one is 'Basic Test' and the other is 'Block Heating Test'. The former is cooperatively performed by ten Japanese Electrical Power Companies, and the latter is done by GESC and NOF Corporation. (authors)
The Fast Flux Test Facility has provided a very useful framework for testing the advances in Liquid Metal Reactor Safety Technology. During the licensing phase, the switch from a nonmechanistic bounding technique to the mechanistic approach was developed and implemented. During the operational phase, the consideration of new tests and core configurations led to use of the anticipated-transients-without-scram approach for beyond design basis events and the move towards passive safety. The future role of the Fast Flux Test Facility may involve additional passive safety and waste transmutation tests. 26 refs.
A method of abrasion testing according to ASTM C 704-76 a is presented for steel fibre concrete mortar, fusion-cast basalt and a surface coating material and results of practical interest are mentioned. Due to the high technical demands on these materials and their specific fields of application, the very first test already supplied interesting findings. From the user's point of view, the method is an interesting alternative to the common test methods, e.g. according to DIN 52 108 (wheel test according to Boehme). In English-speaking countries, testing according to ASTM is often mandatory in the refractory industry in order to assure constant quality of refractory materials after setting. The method is characterized by good comparability and high accuracy of measurement. Only the test piece is exchanged while the test conditions ...
... Abstract : Interlaboratory evaluation of the Radiant Panel Method (ASTM E 162-67) for flame spread testing of two flexible foam and one hardboard ...
BARC has organized an international round robin analysis program to carry out the ultimate load capacity assessment of BARC containment (BARCOM) test model. The test model located in BARC facilities Tarapur, is a 1:4 scale representation of 540 MWe pressurized heavy water reactor (PHWR) pre-stressed concrete inner containment structure of Tarapur Atomic Power Station (TAPS) unit 3 and 4. The features of the BARCOM test model and the constitutive data for the pre-test analysis along with the comparison of the results submitted by various participants are described in this pre-test report of the round robin analysis of BARCOM test model
BackgroundGenetic predisposition to scrapie in sheep is associated with several variations in the peptide sequence of the prion protein gene (PRNP). DNA-based tests...Full Text Available
The Department of Defense (DOD) will soon issue a directive to test all incoming military personnel for the presence of hemoglobin S. The military testing program for hemoglobin S is an occupational...Full Text Available
A series of pipe rupture tests has been performed at JAERI to demonstrate the safety of primary coolant circuits in the event of pipe rupture in nuclear power plants. Pipe whip tests and jet discharge tests have been conducted under BWR and PWR loss-of-coolant accident (LOCA) conditions. The present paper describes the experimental and analytical results of the pipe whip tests performed under PWR LOCA conditions using 4, 6 and 8-inch test pipes. The tests were carried out at an initial pressure and temperature of 15.7 MPa and 325/sup 0/C, respectively. Moreover, a dynamic analysis of pipe whip tests was carried out using the general purpose finite element programm ADINA.
... experts agree-- a colonoscopy is the most accurate test to detect the cancer, but because of cost ... method. Dr. Randall Burt: Colonoscopy is the best test. The question is therefore shouldn't everyone, since ...
The Japan Atomic Energy Research Institute has conducted a piping reliability test program to demonstrate the safety and reliability of light water reactor primary piping. In this program, pipe fatigue test, leak-before-break (LBB) verification test and pipe rupture test were carried out to examine the integrity of piping, to verify the LBB and to demonstrate the effectiveness of protective measures against jet impingement and pipe whip loads under a pipe rupture event.In the pipe fatigue test, a procedure to predict the fatigue crack growth was developed, and the integrity of piping during the plant service life was evaluated. In the LBB verification test, the pipe fracture test and the leak rate test were performed to verify the LBB in the primary piping.In the pipe rupture test, the influence of ...
Pipe whip tests or jet discharge tests have been performed at the Japan Atomic Energy Research Institute, which simulate the instantaneous guillotine break of primary coolant piping in nuclear power plants. This paper describes the results of the 4-inch pipe whip tests(RUN 5407, 5501, 5504, 5603), under the BWR LOCA conditions, which were performed from 1979 to 1981. The test pressure was 6.8 MPa and test temperature 285/sup 0/C. In these tests, clearance was kept constant at the value of 100 mm and overhang lengths were 250, 400, 550 and 1,000 mm, respectively. The main purpose of these tests is to investigate the effect of overhang length on pipe whip behavior. From the tests results, the pipe movement is effectively limited by the restraints if the overhang length is 250 mm or 400 mm. The deformation of the ...
JAERI has been performing transient core thermal-hydraulic test program. In the program, authors performed BWR/ABWR DBE simulation tests with a test facility, which can simulate BWR/ABWR transients. The test facility has a 4 x 4 bundle core simulator with 15-rod heaters and one non-heated rod. Through the tests, authors quantified the thermal safety margin for core cooling. In order to quantify the thermal safety margin, authors collected experimental data on post-CHF. The data are essential for the evaluation of clad temperature transient when core heat-up occurs during DBEs. In comparison with previous post-CHF tests, present experiments were performed in much wider experimental condition, covering high clad temperature, low to high pressure and low to high mass flux. Further, data at wider elevation (lower to higher elevation of core) were obtained in the ...
The aim of the classical multiple test strip is to perform routine chemical analysis in one single operation, yielding maximum diagnostic and prognostic information. A maximum of 10 test areas should not be exceeded. The efficiency of the currently marketed test strips is discussed and improvements within acceptable price limits are suggested. PMID:10841930
Modern microprocessor-based relays for the protection of the various power system components such as generators, transformers, feeders, and high voltage transmission lines are becoming more sophisticated as increasingly more complex functions and capabilities can be included in the microprocessor. With this increasing complexity, and the increasing complexity of the power system itself, there is even more value in testing the suitability of relaying equipment for the intended applications. This paper reviews the testing philosophy, experience, and capabilities developed at Ontario Hydro over more than 25 years of testing protective relays.
... and testing of unidirectional composites, there are serious doubts about the possibility of obtaining a true ultimate compressive strength for this kind ...
Operational Final Test Report for Integrated Systems, Project W-030 (Phase 2 test, RECIRC and HIGH-HEAT Modes). Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks, including upgraded vapor space cooling and filtered venting of tanks AY101, Ay102, AZ101, AZ102.
Due to their good hydraulic characteristic semi-axial pump turbines are used in the medium head range of pumped storage plants. This paper describes model tests performed on a semiaxial pump turbine model and shows the results of these tests. The aim of the model tests was the optimization of the hydraulic water passage, the measurement of the hydraulic characteristics over the whole operating range, the investigation of the cavitation behaviour, the investigation of the hydraulic forces and torques as well as the proof of the values guaranteed to the customer.
This document describes the High Performance Electrical Modeling and Simulation (HPEMS) Global Verification Test Suite (VERTS). The VERTS is a regression test suite used for verification of the electrical circuit simulation codes currently being developed by the HPEMS code development team. This document contains descriptions of the Tier I test cases.
This document describes the High Performance Electrical Modeling and Simulation (HPEMS) Global Verification Test Suite (VERTS). The VERTS is a regression test suite used for verification of the electrical circuit simulation codes currently being developed by the HPEMS code development team. This document contains descriptions of the Tier I test cases.
In this study, an apparatus suitable to photoacoustic (PA) imaging to measure blood-analysis and urinalysis is fabricated and its measurement scheme has been established for the first time. The PA imaging of urinalysis test strip, blood sugar test strip, and cholesterol test strip is performed. A calibration curve of PA measurement is obtained for a urine test strip. The detectivity is better than that obtained by an eye-measurement.
Testing results obtained from simple shear and direct shear tests were conducted for investigating the frictional properties between steel pile shaft and silty clay in this paper. By using the analyzed results of these tests, a hyperbolic curve fitting method for estimating skin friction of pile shaft was proposed in which was verified by its application on the results of undrained uplift triaxial model pile tests.
Prior to an industrial-scale test of zinc/air batteries at Greven, the TUeV Bayern-Sachsen carried out preliminary tests on behalf of the Deutsche Bundespost. The results were quite promising: The energy density of the new battery is ten times as high as that of conventional lead batteries, and the battery-powered test vehicle had a range of up to 300 km. (orig.)
The performance of the leukocyte test area of the new multiple urine test strip, Multistix-10-SG, was evaluated in both field trials and model experiments. The detection limit was found to be adequate for routine purposes. Unspecific reactions are rare and generally indicated by the results of the other test areas. PMID:3572312
Safety-related instrument in nuclear power plants must be checked for reliability over their projected operating life. A method of conducting accelerated aging tests is presentd. It uses the Arrhenius activation energy concept and manipulation of the parameters of the test e.g. by raising test temperature, by relying on a model characterizing the chemical-related reactions of materials.
Extensive well testing in geothermal resources has been carried out throughout the western United States and in northern Mexico since 1975. Each resource tested and each well test conducted by LBL during the eight-year period are covered in brief. The information, collected from published reports and memoranda, includes test particulars, special instrumentation, data interpretation when available, and plots of actual data. Brief geologic and hydrologic descriptions of the geothermal resources are also presented. The format is such that well test descriptions are grouped, in the order performed, into major sections according to resource, each section containing a short resource description followed by individual test details. Additional information regarding instrumentation is provided. Source documentation is provided throughout to facilitate access to further ...
Acceptance Testing of the WRAP 1 Plant Control System Hardware will be conducted throughout the construction of WRAP I with the final testing on the Process Area hardware being completed in November 1996. The hardware tests will be broken out by the following functional areas; Local Control Units, Operator Control Stations in the WRAP Control Room, DMS Server, PCS Server, Operator Interface Units, printers, DNS terminals, WRAP Local Area Network/Communications, and bar code equipment. This document will contain completed copies of each of the hardware tests along with the applicable test logs and completed test exception reports.
The purposes of this report are (1) to perform a Verification and Validation (V and V) test for the VIPEX(Vital-area Identification Package EXpert) software and (2) to improve a software quality through the V and V test. The VIPEX was developed in Korea Atomic Energy Research Institute (KAERI) for the Vital Area Identification (VAI) of nuclear power plants. The version of the VIPEX which was distributed is 3.2.0.0. The VIPEX was revised based on the first V and V test and the second V and V test was performed. We have performed the following tasks for the V and V test on Windows XP and VISTA operating systems: ? Testing basic functions including fault tree editing ? Testing all kind of functions ? Research for update from Visual BASIC 6.0 to Visual BASIC 2008
A series of six transient tests was performed on FFTF irradiated fuel pins to demonstrate their transient performance capability. The tests were performed in the TREAT reactor using sodium loops and instrumented test trains. The TEMECH computer code was used to design overpower transients which would simulate FFTF fuel pin thermal conditions during slow and fast unprotected transients. Some tests were run to substantial overpower levels but terminated prior to fuel pin failure, while other tests were intentionally extended to fuel failure to establish failure thresholds and characteristics. Post-test examination data provided significant cladding strain and fuel melting information used for performance code calibration and validation. These data showed that cladding damage caused by fuel melting is related to the steady state condition of the fuel.
Purpose - The purpose of this paper is to help library technology staff understand the process of beta testing software, determine if it is appropriate for them to engage in the process, and provide suggestions on how to the time invested in the process. Design/methodology/approach - The paper explains what beta testing is, why it should be used and how to become a beta tester. Findings - The paper reveals that beta testing is not convenient for everyone, but those taking place in these activities should be thorough, positive and generous in order to maximize the return on investment in this kind of testing. Practical Implications - While beta testing new software features can take a significant amount of time, the resulting benefits of early access to new features and improved vendor-staf...
A series of tests were completed at the Fast Flux Test Facility to demonstrate the passive safety characteristics of liquid metal reactors with natural circulation flow. The first test consisted of transition from forced to natural circulation flow at an initial decay power of 0.3%. The second test represented an unprotected loss-of-flow transient to natural circulation from 50% power with the control rods prevented from scramming into the core. The third test was a steady-state, natural circulation condition with core fission powers up ato about 2.3%. Core sodium data and results of single and multi-channel computer models confirmed the reliability and effectiveness of natural circulation flow for liquid metal reactor safety.
The ALPHA project is centered around the experimental and analytical investigation of the long-term decay heat removal from the containments of the next generation of open-quotes passiveclose quotes ALWRs. The project includes integral system tests in the large-scale (1:25 in volume) PANDA facility as well as several other series of tests and supporting analytical work. The first series of experiments to be conducted in PANDA have become a required experimental element in the certification process for the General Electric Simplified Boiling Water Reactor (SBWR). The PANDA general experimental philosophy, facility design, scaling, and instrumentation are described. Steady-state PCCS condenser performance tests and extensive facility characterization tests were already conducted. The transient system behavior tests are underway; preliminary results from the first transient ...
A program of tests were conducted in July 1986 at the Fast Flux Test Facility (FFTF) to demonstrate that the reactor could withstand a prototypic loss of flow (LOF) without scram without sustaining fuel damage. The reactor was taken to powers up to 50%, and the main primary coolant pump motors were tripped without scramming the control rods. This paper summarizes the analyses performed to demonstrate the maintenance of redundant protection for all design events as well as potential new events introduced by the test. The analyses focused on the following consequences: (1) unexpected test behavior; (2) transient overpower event during the test; and (3) LOF event during the test.
This paper describes new test methodologies to obtain data used to evaluate the ultimate seismic strength of Nuclear Power Plant (NPP) equipment related to nuclear safety. The paper first reviews existing equipment seismic test data from the viewpoint of the evaluation of their ultimate seismic strength and/or seismic design margins, and extracts the issues in the existing data with regard to their applicability to the evaluation. Then, the paper proposes new test methodologies for the equipment to evaluate their ultimate seismic strength. The test methodology of the equipment employs a vibration amplification system to a shaking table and enhances its applicable maximum acceleration up to 6g. The test methodology herein is cost effective for obtaining test data that is indispensable for evaluating proper seismic margins of NPPs. (author)
We provide a detailed overview of an on-going, multinational test programme that is developing aerosol data for some spent fuel sabotage scenarios on spent fuel transport and storage casks. Experiments are being performed to quantify the aerosolised materials plus volatilised fission products generated from actual spent fuel and surrogate material test rods, due to impact by a high-energy/density device. The programme participants in the United States plus Germany, France and the United Kingdom, part of the international Working Group for Sabotage Concerns of Transport and Storage Casks (WGSTSC) have strongly supported and coordinated this research programme. Sandia National Laboratories has the lead role for conducting this research programme; test programme support is provided by both the US Department of Energy and the US Nuclear Regulatory Commission. We provide a summary of the overall, multiphase ...
We provide a detailed overview of an on-going, multinational test programme that is developing aerosol data for some spent fuel sabotage scenarios on spent fuel transport and storage casks. Experiments are being performed to quantify the aerosolised materials plus volatilised fission products generated from actual spent fuel and surrogate material test rods, due to impact by a high-energy/density device. The programme participants in the United States plus Germany, France and the United Kingdom, part of the international Working Group for Sabotage Concerns of Transport and Storage Casks (WGSTSC) have strongly supported and coordinated this research programme. Sandia National Laboratories has the lead role for conducting this research programme; test programme support is provided by both the US Department of Energy and the US Nuclear Regulatory Commission. We provide a summary of the overall, multiphase ...
The authors provide a detailed overview of an on-going, multinational test program that is developing aerosol data for some spent fuel sabotage scenarios on spent fuel transport and storage casks. Experiments are being performed to quantify the aerosolized materials plus volatilized fission products generated from actual spent fuel and surrogate material test rods, due to impact by a high-energy-density device. The program participants in the United States plus Germany, France and the United Kingdom, part of the international Working Group for Sabotage Concerns of Transport and Storage Casks (WGSTSC) have strongly supported and coordinated this research program. Sandia National Laboratories has the lead role for conducting this research program; test program support is provided by both the US Department of Energy and the US Nuclear Regulatory Commission. The authors provide a summary of the overall, multiphase ...
The authors provide a detailed overview of an on-going, multinational test program that is developing aerosol data for some spent fuel sabotage scenarios on spent fuel transport and storage casks. Experiments are being performed to quantify the aerosolized materials plus volatilized fission products generated from actual spent fuel and surrogate material test rods, due to impact by a high-energy-density device. The program participants in the United States plus Germany, France and the United Kingdom, part of the international Working Group for Sabotage Concerns of Transport and Storage Casks (WGSTSC) have strongly supported and coordinated this research program. Sandia National Laboratories has the lead role for conducting this research program; test program support is provided by both the US Department of Energy and the US Nuclear Regulatory Commission. The authors provide a summary of the overall, multiphase ...
Rocket-Based Combined-Cycle (RBCC) engines intended for missiles and/or space launch applications incorporate features of rocket propulsion systems operating in concert with airbreathing engine cycles. Performance evaluation of these types of engines, which are intended to operate from static sea level take-off to supersonic cruise or accerlerate to orbit, requires ground test capabilities which integrate rocket component testing with airbreathing engine testing. A combined cycle engine test facility has been constructed in the General Applied Science Laboratories, Inc. (GASL) Aeropropulsion Test Laboratory to meet this requirement. The facility was designed to support the development of an innovative combined cycle engine concept which features a rocket based ramjet combustor. The test requirements included the ability to conduct tests in ...
The purpose of this document is to use existing documentation to review the effectiveness of subsurface flow and surface flow constructed wetlands in treating wastewater and to demonstrate the viability of treating effluent from Savannah River Site outfalls H-02 and H-04 with a subsurface flow constructed wetland to lower copper, lead and zinc concentrations to within National Pollutant Discharge Elimination System (NPDES) Permit limits. Constructed treatment wetlands are engineered systems that have been designed and constructed to use the natural functions of wetlands for wastewater treatment. Constructed wetlands have significantly lower total lifetime costs and often lower capital costs than conventional treatment systems. The two main types of constructed wetlands are surface flow and subsurface flow. In surface flow constructed wetlands, water flows above ground. Subsurface flow constructed wetlands are designed to keep the water level below the top of the rock or gravel media, ...
As a condition of accession into the European Union (EU), Lithuania is committed to the closure and decommissioning of Ignalina NPP comprising two RBMK-1500 reactor units (Fig. 1). It was agreed in a special protocol to the Accession Treaty that, in return for adequate EU financial assistance, Unit 1 would be closed before 2005 and Unit 2 by the end of 2009. The first unit was duly shut down on December 31, 2004. Lithuania, which has borders with Russia (Kaliningrad territory), Poland, Latvia and Belarus, spent fifty years as part of the Soviet Union and was deeply integrated into its economy and electrical infrastructure. At the break-up of the USSR, Lithuania inherited electricity generating capacity designed to supply the north-west region including ownership of Ignalina NPP located in the north-east of the country. Ignalina NPP Unit 1 was commissioned in 1983, Unit 2 in 1987; the planned lifespan of each unit was 30 years. Construction of a third unit was started but never ...
A schematic of the Bench cavity receiver system is given, and the primary objectives, schedule and research plan for each of four tests are discussed. The tests are: (1) cold flow testing to functionally check all valves and their response using high pressure nitrogen gas; (2) a hot checkout to simulate both steady state and transient flux inputs to the receiver which are expected at the French facility; (3) basic performance using solar energy at the French facility; and (4) ir radiant heat testing. (LEW)
The TS-1 and TS-2 Transient Reactor Test Facility (TREAT) experiments were conducted on irradiated Fast Flux Test Facility (FFTF) fuel pins to characterize their failure behavior when subjected to hypothetical 5%/s transient overpower conditions. The TS-1 test employed a near-fresh (2 MWd/kg) fuel pin, while the TS-2 test used a medium-burnup (58 MWd/kg) fuel pin. Transient conditions were closely matched between the two experiments to provide a direct comparison of burnup effects on the failure response.
The Programmable Logic Controller (PLC) for use in Nuclear Power Plant safety-related applications is being developed and tested first time in Korea. This safety-related PLC is being developed with requirements of regulatory guideline and industry standards for safety system. To test that the quality of the developed PLC is sufficient to be used in safety critical system, document review and various product testings were performed over the development documents for S/W, H/W, and V/V. This paper provides the performance testing methodology and its effectiveness for PLC platform conducted by KOPEC
Data are presented from the intermediate scale borehole test, an in situ test fielded in the pillar separating Rooms C1 and C2 at the Waste Isolation Pilot Plant (WIPP). The test was to provide data on the influence of scale, if any, on the structural behavior of underground openings in salt. These data include selected fielding information, test configuration, instrumentation activities, and comprehensive results from a large number of gages. Construction of the test began in December 1989, with the drilling of the intermediate scale borehole in December 1990. Gage data in this report cover the period from January 1989 through June 1993.
In order to assess whether an oil shale test facility would be of significant use to private sector oil shale developers, the US DOE has studied the past history of oil shale development and its potential for replacing petroleum supplies. A generic test facility's primary function would be to test concepts of mining, retorting, upgrading, and environmental aspects at the engineering scale. This paper summarizes the US oil shale resources, gives a technology analysis, and discusses the potential for a test facility.
This study deals with the application of wavelet analysis to detection and characterization of defects from eddy-current and ultrasonic testing signals of a low signal-to-noise ratio. Presented in this paper are the methods for processing eddy-current testing signals of heat exchanger tubes of a steam generator in a nuclear power plant. The results of processing eddy-current testing signals of tube test pieces with artificial flaws show that the flaw signals corrupted by noise and/or non-defect signals can be effectively detected and characterized by using the wavelet methods. (author)
...com: The Art of Application Performance Testing : Help for Programmers and Quality Assurance (9780596520663): Ian Molyneaux: Books Amazon.com:...The Art of Application Performance Testing : Help for Programmers and Quality Assurance (9780596520663): Ian Molyneaux: Books Ian Molyneaux,The ...Art of Application Performance Testing : Help for Programmers and Quality Assurance,O'Reilly Media,0596520662,LA9780596520663,Computer Books: General,Application software,Computer software,...com: The Art of Application Performance Testing : Help for Programmers and Quality Assurance (9780596520663): Ian Molyneaux: Books ...
Many of today's automated real-time testing systems for embedded systems were developed using expensive custom hardware and software. In this article they describe how to use commercially available off-the-shelf hardware and software to design and develop an automated real-time test systems for Embedded Programmable Logic Controller (PLC) Based Control Systems. The system development began with the implementation of the VALI/TEST Pro testing methodology as a means for structuring the testing. Using this methodology, they were able to decompose system requirement documents for a Personnel Safety System (PSS) into its high, intermediate and detail level requirements. next, the validation procedures for the PSS system were decomposed into testing units called builds, test runs and test cases. To measure the PSS ...
There are very few examples of audio-based computerized tests, but for many disciplines, such as foreign language and music, there appear to be many benefits to this type of testing. The purpose of the present study was to develop and compare computer-delivered and audiocassette/paper-and-pencil versions of a listening test. The test was a measure of progress achievement of academic listening comprehension and vocabulary for high-intermediate level students of English as a Second Language (ESL) at a university-affiliated institute. The underlying assumption investigated was that the use of computer and audio technology for classroom progress tests would provide benefits of convenience and improved sound quality while providing measurement quality and validity that were at least comparable to the paper form of such tests. Results with 28 students indicate that ...
Material testing of SPF-sheet is usually done with coupon hot tensile testing. The optimum range of strain rates is determined with stepped strain tests. To overcome the problem of very few available testing facilities and time consuming and costly procedure, cone cup testing has been developed since long. This test can be generated directly in the workshop, no machining of samples is necessary and it is very much related to the real SPF-process. The analysis of suitable temperature and strain rate is done by simple measurement of resulting cone height. This paper describes a unique and novel variant of the above mentioned baseline design. It provides on-line data of the actual status of the cone cup forming resulting from the applied, constant pressure. Strain rate variations as a result from texture or from the alloy-related behaviour is detectable. Thinning ...
The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled test reactor located on the Hanford Site. The FFTF is the only reactor of this type designed and operated with the intent of meeting the licensing requirements of the Nuclear Regulatory Commission (NRC). Unique characteristics of the FFTF that present special challenges related to leak rate testing include thin wall containment vessel construction, cover gas systems that penetrate containment, and a low-pressure design basis accident. The successful completion in 1986 of the third FFTF Integrated Leak Rate Test (ILRT) five days ahead of schedule and 10% under budget was a major achievement for the Westinghouse Hanford Company. The success of this operational safety test was due in large part to a special local area network (LAN) of three IBM PC/XT computers that monitored the sensor data, calculated the containment vessel ...
This report describes the design of a well test to determine two-phase hydraulic properties of a low permeability, low porosity formation. Estimation of gas-related parameters in such formations is difficult using standard pumping tests mainly because of the strong fluctuations in the pressure and flow rate data which are a consequence of gas bubbles evolving in the test interval. Even more important is the fact that the data do not allow distinguishing among alternative conceptual models. The estimated parameters are therefore uncertain, highly correlated, and ambiguous. In this study we examine a test sequence that could be appended to a standard hydraulic testing program. It is shown that performing a series of water and gas injection tests significantly reduces parameter correlations, thus decreasing the estimation error. Moreover, the extended ...
Constant extension rate (CERT) tests were performed on Alloy 690 and Alloy 800 nuclear steam generator tubing specimens. For the Alloy 690 specimens, tests were performed in deaerated 10% sodium hydroxide solutions at 315 deg C with a +100 mV applied potential. For the Alloy 800 specimens, tests were performed in deaerated 5% sodium hydroxide solutions at 343 deg C with no applied potential. The test specimens were machined from tubing which was produced by different manufacturing processes and in different heat treated conditions. The Alloy 690 tubing was tested in six different thermomechanical conditions, while the Alloy 800 tubing was tested in four different thermomechanical conditions. The results from the test program include a complete microstructural examination using light-optical and scanning electron microscopy. The CERT ...
Many mechanical parts are subjected to stresses and strains that may eventually lead to their failure. In order to prevent the costly delays associated with equipment down-time, many parts have to be tested for weaknesses and defects when machinery is constructed or dismantled for maintenance. These procedures are known as Non-Destructive Testing (NDT) methods. Five types of non-destructive testing methods routinely used are radiographic testing, ultrasonic testing, magnetic particle inspection, liquid penetrant testing and eddy current testing. Out of these five techniques industrial radiography plays an important role in non-destructive testing to reveal interior defects in materials. In radiography almost two-thirds of the radiation reaching the film is scattered radiation which does not form the image of defects. ...
The paper describes the experimental and analytical results of the pipe whip tests performed under the PWR LOCA conditions using 4, 6 and 8 inch test pipes. The tests were carried out at an initial pressure and a temperature of 15.7 MPa and 325 "0C. Two different types of tests were performed. One was the cantilever type pipe whip test using the test pipe of 3000 mm in length and U-shaped restraints. The other was the cross-over leg pipe whip test using a 1/6 model of piping in the PWR nuclear power plants. The cantilever type pipe whip tests were performed to investigate the influences of overhang length and pipe diameter on the pipe whip behavior. The movement of the test pipe is limited effectively by the restraints when the overhang length is short. The restraint force increases in proportion to ...
Series of pipe rupture tests have been performed at the Japan Atomic Energy Research Institute to demonstrate the safety of the primary coolant circuits in the event of pipe rupture in nuclear power plants. The pipe whip tests have been conducted to study the dynamic response of the pipe and restraints. The results of the pipe whip tests using test pipes of 4-inch in diameter under the BWR LOCA conditions (285"0C, 6.8 MPa) were reported in the previous paper F8/5 of the 6th SMiRT. The present paper describes the results of the pipe whip tests using test pipes of 6-inch in diameter. The test pipe was made of Type 304 stainless steel and was 165.2 mm in outer diameter and 11.0 mm in thickness, and was fixed at the pipe support so that the length of the test section was 3000 mm. The restraints were made of Type 304 ...
The laboratory environment existing outside the test situation itself can have a substantial influence on results of some behavioral tests with mice, and the extent of these influences sometimes depends on genotype. For alcohol research, the principal issue is whether genotype-related ethanol effects will themselves be altered by common variations in the lab environment or instead will be essentially the same across a wide range of lab environments. Data from 20 inbred strains were used to reduce an original battery of seven tests of alcohol intoxication to a compact battery of four tests: the balance beam and grip strength with a 1.25g/kg ethanol dose and the accelerating rotarod and open-field activation tests with 1.75g/kg. The abbreviated battery was then used to study eight inbred str...
A series of tests was recently completed at the 400-MW (thermal) Fast Flux Test Facility (FFTF) to further demonstrate the passive safety characteristics of liquid-metal-cooled fast reactors. Earlier FFTF testing of decay heat removal by sodium natural circulation was reported in 1981. The main purpose of the 1986 test series was to demonstrate passive reactor shutdown during a loss-of-flow event when several inherent shutdown devices called gas expansion modules (GEMs) were installed in the reactor. However, these tests also provide further data on the natural circulation performance of the primary system, in particular the reactor core, and thus add to the data base available for checking the validity of available analytical tools.
The OSP (Operating Safety Procedure) required for performance of electrical arc testing of CFC replacement fluids was renewed. Electrical breakdown tests at one atmosphere pressure have been performed for R-22, R-134a, and R-125/R-143a (50:50 blend; R-507), and breakdown products identified. No differences in HCFC breakdown products are seen in the presence or absence of lubricant oils. The design of the high pressure-high temperature test stand has been finalized, and construction initiated during this quarter. Three motor stators and rotors were received from Tecumseh Products Company for use in motor burnout tests. A test plan for the motor breakdown tests is in preparation.
A multi-centre evaluation of the test strip analyser, Rapimat, was performed by four laboratories following the ECCLS 2nd draft guidelines for the evaluation of analysers in clinical chemistry. Using the Rapignost urine test strip with the test fields for bilirubin, urobilinogen, acetoacetate, ascorbic acid, glucose, protein, nitrite, pH and haemoglobin, the Rapimat was found to be analytically reliable in comparison with other, in most cases quantitative procedures. During the observation period of about 6 months no breakdown occurred in any laboratory. Interferences and sensitivity as discussed for the bilirubin and urobilinogen test field are more related to the test strip than to the instrument. Several improvements for further developments are suggested. This multi-centre study has shown that the ECCLS protocol is applicable to analytical procedures leading to discrete results. ...
Greenman J, Thorn RMS, Saad S, Austin AJ. In vitro diffusion bed, 3-day repeat challenge `capacity' test for antimicrobial wound dressings. Int Wound J 2006;3:322-329. Abstract The aim of this study was to develop an in vitro wound infection model that allows the comparison of the bacterial kill rate of antimicrobial wound dressings over the course of 3 days, with renewed microbial challenges each day, under realistic wound-like conditions. A test bed model of a moderately exuding wound was constructed from a hydrogel containing releasable foetal calf serum (FCS), and cellulose discs dosed with test microbes (Methicillin-resistant Staphylococcus aureus and Pseudomonas aeruginosa) suspended in 50% FCS applied at the interface between the test dressing and the hydrogel test bed. Freshly prep...
The Fast Flux Test Facility (FFTF) is a 400 Mwt sodium-cooled fast reactor operating at the Hanford Engineering Development Laboratory, Richland, Washington, to conduct fuels and materials testing in support of the US Liquid Metal Fast Breeder Reactor (LMFBR) program. Startup and initial power testing included a comprehensive series of nonnuclear and nuclear tests to verify the thermal, hydraulic, and neutronic characteristics of the plant. A specially designed series of natural circulation tests were then performed to demonstrate the inherent safety features of the plant. Early in 1982, the FFTF began its first 100-day irradiation cycle. Since that time the plant has operated very well, achieving a cycle capacity factor of 94% in the most recent irradiation cycle. Seventy-five specific test assemblies and 25,000 individual fuel pins have been irradiated, some ...
A technique for the measurement of the total hemispherical emittance of pipe surfaces is described, and design and operational details are given. The technique is conceptually simple. A long test pipe (e.g., 3.4 m) is mounted concentrically inside a Pyrex glass pipe. The system is evacuated, and the test pipe is heated by means of an electrical resistance heater. Heat transfer from the test pipe to the enclosure is almost solely radiative, allowing an average emittance for the test pipe and the Pyrex pipe and the electrical power input to the heater. By varying the electrical power level, one can measure the test pipe emittance as a function of temperature. By using a simple correction to account for the finite length of the test pipe, one can calculate the results using the simple expression for infinite, concentric cylinders. Results agree with measurements by ...
Background. Reports of positive patch test and photopatch test reactions to the chemical ultraviolet filter octocrylene have increased during the last decade. Little is known about the reason for octocrylene's allergenic activity. Objectives. To present and discuss the results of patch tests and photopatch tests with octocrylene, and to investigate the possible cause of its allergenic properties. Methods. Results of patch tests and photopatch tests with octocrylene in patients with adverse skin reactions to sunscreen products and/or ketoprofen were collected. The allergenic potency of octocrylene was investigated in the murine local lymph node assay (LLNA). Chemical reactivity assays were used to mimic octocrylene's interaction with biomolecules. Results. We report 23 cases of positive tes...
The Fast Flux Test Facility (FFTF) is a 400 MW(th) sodium cooled reactor and is the largest test reactor of its type in the world. It was designed and is being operated to serve two purposes: gaining liquid metal system experience and serving as a test bed for fuels and materials. During test operations it is possible that cladding breaches and escape of fission gas to the reactor cover gas region can occur. To identify the source of such a leak all 78 fuel pin assemblies contain ''gas tag'' with a unique ''tag'' mixture in each assembly. The mass spectrometric identification of tag isotope ratios makes possible rapid location and thus faster removal (if required) of breached test pins.
A review of tests on earthquake-resistant reinforced concrete structural walls is presented. Laboratory tests of isolated walls and construction joints are discussed. Where appropriate, design recommendations are given. The review indicates only few experimental data are available for short walls which are directly applicable to nuclear power plant design. In particular, tests of short rectangular walls subjected to load reversals are needed. Tests are also needed to determine the damping and frequency characteristics of cracked short walls. Analytical and experimental results should be correlated so that the hysteretic response observed in tests can be realistically related to the analytical response 'demand' of nuclear power plant structures. (Auth.).
This document describes the development testing phase associated with the OTA Shear activity and defines the controls to be in place throughout the testing. The purpose of the OTA Shear Program was to provide equipment that is needed for the processing of 40 foot long, sodium wetted, irradiated core components previously used in the FFTF reactor to monitor fuel and materials tests. There are currently 15 of these OTA test stalks located in the Test Assembly Conditioning Station (TACS) inerted vault. These need to be dispositioned for a shutdown mission to eliminate this highly activated, high dose inventory prior to turnover to the ERC since they must be handled by remote operations. These would also need to be dispositioned for a restart mission to free up the vault they currently reside in. The waste handling and cleaning equipment in the J33M Cell was designed and built for the ...
Hydrologic information is essential for environmental efforts at Los Alamos National Laboratory. Testing at new characterization wells being drilled to the regional aquifer (''R wells'') to improve the conceptual hydrogeologic model of the Pajarito Plateau is providing such information. Drilling has been by air-rotary casing-advance or open-hole methods. Most wells are completed with multiple screens. After their construction, wells were rigorously developed by wire-brushing, bailing, followed by surging, swabbing, or jetting, and finally by pumping. These methods are effective based on field-parameter measurements and comparison of results of hydrologic testing at well R-31 before and after complete well development. We conducted field tests on various zones of saturation penetrated by the R wells to collect data needed for determining hydraulic properties. This document provides details ...
This report provides the results of a JASON review of the technical feasibility of using the Department of Energy`s (DOE`s) Fast Flux Test Facility (FFTF) to generate tritium needed for the enduring United States nuclear weapons stockpile.
The basic features and advantages of a turbodrill with a reducer insert are given, together with its characteristics in different compositions. The results of industrial tests of a test lot in three areas are given. The effectivenss of using a reducer turbodrill in super-deep holes is demonstrated.
It is of utmost importance to have a computer code in order to analyze how different parameters (like test duration time) affect the unavailability of safety systems of nuclear. In this context, a study was performed in order to evaluate the model employed by the FRANTIC computer code, which performs detailed calculations on the contribution to the system unavailability originated by hardware failures, component tests and repairs, aiming at considering the influence of different test schemes on the system unavailability. It was shown, by means of the results attained that the numerical model used by the FRANTIC code and the analytical model proposed by APOSTOLAKIS and CHU (4) give unavailability values much similar when the component tests are supposed to be perfect. When a test is supposed to be imperfect (that is, when it may induce a test is supposed to be ...
BackgroundMany studies have evaluated the accuracy of dipstick tests as rapid detectors of bacteriuria and urinary tract infections (UTI). The lack of an adequate explanation for...Full Text Available
The use of an extraction of the heme pigments hemoglobin and myoglobin as a test for the heat exposure of back bacon was investigated by treating back bacon at varying temperatures of 50-70 degrees...Full Text Available
Game theory models of animal contests make many non-mutually exclusive predictions, complicating empirical tests. These predictions regard the relationship between contest parameters and fighting ability,...Full Text Available
BackgroundWith a growing number of genetic tests becoming available to the health and consumer markets, genetic health care providers in Canada are faced with the challenge of developing...Full Text Available
The activities of some semisynthetic penicillins and cephalosporins have been tested against clinical strains of Staphylococcus aureus. The apparent activity in vitro varies with the method of testing...Full Text Available
Today, hospitals are involved extensively in social marketing and promotional activities. Recently, investigators from the Centers for Disease Control and Prevention (CDC) estimated that routine testing...Full Text Available
Requirements for the installation, inspection, and testing that assure the quality of important components of a nuclear power plant during construction are presented.
Chemicals having a capacity to disturb the endocrine system have attracted considerable interest during recent years. There is a shortage of well-characterized in vivo tests with which to study such...Full Text Available
Experienced users of the Clarion cochlear implant were tested acutely with the HiResolution (HiRes) and HiRes Fidelity120 (F120) processing strategies. Three psychophysically-based tests were...Full Text Available
This report describes a field-test program to determine the effectiveness of a polymeric wall sealant to reduce the escape of naturally occurring radioactive gas radon from the walls of an underground uranium mine into the ventilation air.
Bench Scale methane cracking tests have been completed using a stack of ten whole SAES(R) St909 pellets - a 6 gram sample size. Methane was found to be the most difficult impurity to process and can impact diffuser operation.
Bench Scale methane cracking tests have been completed using a stack of ten whole SAES(R) St909 pellets - a 6 gram sample size. Methane was found to be the most difficult impurity to process and can impact diffuser operation.
...and biological processes acting on recruitment and post-recruitment EU-Agrinet - Project sheet: Biological performance testing methodology to evaluate the durability of plywood as a quality indicator ... Project sheet: Biological performance testing methodology to evaluate the durability of plywood as a quali EU-Agrinet - Project sheet: Genetic evaluation of European ...
Direct identification of group B streptococci from a selective broth medium was performed with the Phadebact streptococcus test to determine the feasibility of this technique for early detection of...Full Text Available
Multidrug-resistant tuberculosis is an increasing public health concern in many parts of the world, especially in low-income countries, where most cases occur. Traditional drug susceptibility testing...Full Text Available
Handheld, backpack, and mobile sensors are elements of the Global Nuclear Detection System for the interdiction and control of illicit radiological and nuclear materials. They are used by the U.S. Department of Homeland Security (DHS) and other government agencies and organizations in various roles for border protection, law enforcement, and nonproliferation monitoring. In order to systematically document the operational performance of the common commercial off-the-shelf portable radiation detection systems, the DHS Domestic Nuclear Detection Office conducted a test and evaluation campaign conducted at the Nevada Test Site from January 18 to February 27, 2006. Named 'Anole', it was the first test of its kind in terms of technical design and test complexities. The Anole test results offer users information for selecting appropriate mission-specific portable ...
The guide describes a method acceptable to the NRC staff for complying with the Commission's regulations with regard to quality assurance requirements for installation, inspection, and testing of mechanical equipment and systems for water-cooled and high-temperature gas-cooled nuclear power plants.
This plan describes the Quality Assurance Program which will be applied to spent fuel handling and packaging tests conducted at the Area 25 E-MAD facility, Nevada Test Site (NTS).
The past decade has seen rapid advances in the identification of associations between candidate genes and a range of common multifactorial disorders. This paper evaluates public attitudes towards the...Full Text Available
In the fuel testing facilities of Japan Atomic Energy Research Institute, the post-irradiation test of practical fuel used in nuclear power stations was begun in December, 1979, and the soundness of practical fuel has been confirmed, and the valuable post-irradiation test data on the behavior of fuel have been acquired. Recently, the heightening of fuel burnup has been advanced, and also in fuel testing facilities, the development and preparation of the post-irradiation testing facility required for examining in detail high burnup fuel have been carried out. The course of the installation of the post-irradiation testing facility and the outline of the facility are reported. As the preparation of the post-irradiation testing facility for high burnup fuel, a hyperfine hardness tester that measures dynamic hardness, the measuring instrument for ...
BackgroundRapid and correct diagnosis of malaria is considered an important strategy in the control of the disease. However, it remains to be determined how well these tests can...Full Text Available
... Austrian Environment Minister Nikolaus Berlakovich called for such stress tests on Sunday (13 March) to make sure that nuclear power stations were quake-proof following Japan's massive earthquake and tsunami. Austria, a mountainous country rich in geothermal energy, has no NPPs and no plans to develop ...
We have exploited ``progeny testing'' to map quantitative trait loci (QTL) underlying the genetic variation of milk production in a selected dairy cattle population. A total of 1,518 sires, with progeny...Full Text Available
NUPEC has carried out hydrogen mixing tests to investigate hydrogen distribution behavior within a model containment and to provide a set of experimental data for validation of severe accident analysis codes.
The fusion materials program has little irradiation effects data at temperatures from 100 to 350 degree C. Near-term machines such as the International Thermonuclear Engineering Reactor (ITER) will expose materials to neutron doses of 38 to 50 dpa at 150 degree C or less. The data base for structural materials must be extended into this range. Also, lower temperatures are needed to investigate the lower bound for tritium release from solid breeder materials. A low temperature test vehicle is proposed for the Fast Flux Test Facility (FFTF), which will provide test temperatures of 100 to 350 degree C. An 8.5-cm dia. by 100-cm test volume will be instrumented to collect temperature data and provide feedback for control. The spectrum and flux will provide accelerated damage accumulation for structural materials testing and the best available approximation of fusion reactor conditions ...
This report presents the results of the design testing of large (36-inch diameter) butterfly valves under high flow conditions. The two butterfly valves were pneumatically operated air-open, air-shut valves (termed valves 1 and 2). These butterfly valves were redesigned to improve their ability to function under high flow conditions. Concern was raised regarding the ability of the butterfly valves to function as required with high flow-induced torque imposed on the valve discs during high steam flow conditions. High flow testing was required to address the flow-induced torque concerns. The valve testing was done using a heavily instrumented piping system. This test program was called the Large Scale Steam Valve Test (LSSVT). The LSSVT program demonstrated that the redesigned valves operated satisfactorily under high flow conditions.
Laboratory studies were performed to support field-testing of base injection into the F-Area Seepage Basins groundwater. The general purpose of these experiments is to provide information to guide the test of base injection and to identify potential adverse effects.
A workshop on alternative toxicological testing methodologies was convened by the Scientific Group on Methodologies for the Safety Evaluation of Chemicals (SGOMSEC) 26-31 January 1997 in Ispra, Italy,...Full Text Available
Test Area North (TAN) was a site of the Aircraft Nuclear Propulsion (ANP) Project of the U.S. Air Force and the Atomic Energy Commission. Its Cold War mission was to develop a turbojet bomber propelled by nuclear power. The project was part of an arms race. Test activities took place in five areas at TAN. The Assembly & Maintenance area was a shop and hot cell complex. Nuclear tests ran at the Initial Engine Test area. Low-power test reactors operated at a third cluster. The fourth area was for Administration. A Flight Engine Test facility (hangar) was built to house the anticipated nuclear-powered aircraft. Experiments between 1955-1961 proved that a nuclear reactor could power a jet engine, but President John F. Kennedy canceled the project in March 1961. ANP facilities were adapted for new reactor projects, the most important of which were Loss of Fluid ...
The accelerating development of biochemical and DNA-based diagnostic tests for human genetic conditions in the last decade has engendered a revolution in genetic diagnosis. Both genetic testing and...Full Text Available
A corrosion-testing program has been initiated in Purex and Redox storage tnnks to obtain corrosion data on carbon steel and three associated materials in neutralized process wastes. (C.W.H.)
The purposes of the pipe rupture studies at the Japan Atomic Energy Research Institute are to perform the model tests on the pipe whip of a pipe-restraints system, to get jet impingement force and blowdown thrust force, and to establish the computational method for the analysis of these phenomena. This paper presents the experimental and analytical results of the pipe whip tests carried out under the PWR LOCA conditions using the test pipe of 4-inch diameter and the U-shaped restraints. In the tests, the gap between the test pipe and the restraints was set nearly constant and the overhang length was 250 mm, 400 mm or 650 mm. The dynamic strains and residual deformations of the test pipe and restraints, and the restraint force were measured to clarify the effects of the overhang length on the pipe whip behaviors of the pipe-restraints system. It was confirmed ...
Under a cooperative agreement, the Bureau of Mines, Magma Copper Co., and ASARCO, Inc., tested backfilled ground support systems at two elevations in Magma's San Manuel, AZ, mine. The tests were mainly for guidance in designing the loading crosscuts of th...
Weldability and high temperature strength properties of Hastelloy Alloy XR were investigated in order to evaluate the materials performance of base metal and filler metal for the High Temperature Engineering Test Reactor (HTTR) uses. The weldability was examined by means of the chemical analysis in the deposited metals, optical microscopy, FISCO test, hardness measurements and bend test. The high temperature strength properties were investigated through tensile tests at R.T., 800, 900 and 950degC in air, and creep and creep rupture tests at 900 and 950degC in air. The results obtained by each test showed favorable performance. In particular, the bend test which is considered to be critical pass demonstrated low susceptibility to weld cracking through the optimization of B and C contents in the filler metal and by narrowing the groove. Creep ...
The development of rapid and specific diagnostic tests to identify individuals infected with malaria is of paramount importance in efforts to control the severe public health impact of this disease....Full Text Available
Broth disk elution procedures represent one of the most practical means for clinical laboratories to perform routine antibiotic susceptibility tests on anaerobic bacteria. The accuracy of five disk...Full Text Available
Endocervical swabs from 212 women and urethral swabs from 100 men were tested by the routine methods for McCoy cell culture and simultaneously by a novel enzyme amplified immunoassay test to detect...Full Text Available
situ by isolating portions of the building envelope and performing tests .MAXIMUM ALLOWED LOAD ...and shall identify commissioning team members who will perform testing and prepare documentation.The commissioning agent may be
Current methods for drug susceptibility testing of Mycobacterium tuberculosis are either costly or slow. As the prevalence of multidrug-resistant strains increases, the need for fast,...Full Text Available
The development of structural barriers for nuclear waste packages involves selection of candidate materials, their screening by mechanical and corrosion testing, rigorous accelerated testing, and evaluation and comparison with other package elements. This document presents results from work conducted on titanium and ferrous alloys.
This paper describes the needs, reasoning, approaches, and technical details to establish a practical accelerated weathering test (AWT) protocol for indoor testing of the photothermal stability of encapsulation materials and encapsulated solar cells and minimodules.
Haemophilus parasuis causes polyserositis in swine. Fifteen serovars have been characterized by immunodiffusion test, but many field strains are not typeable. Isolates (n...Full Text Available
Cited are the results of physico-chemical studies and industrial tests of a copolymer of methacrylic acid and diethylammonium salt, used for limiting the influx of stratum waters into a well.
A nucleic acid extraction system that can handle small numbers of specimens with a short test turnaround time and short hands-on time is desirable for emergent testing. We performed a comparative validation...Full Text Available
Lipopolysaccharides from different bacteria isolated from cotton were purified and chemically analyzed. Their pulmonary toxicity to animals was tested in inhalation tests. Lipopolysaccharides from Agrobacterium...Full Text Available
The techniques of thermogravimetry and derivative thermogravimetry (dTG) have been applied to a range of fuel oils and two 'fingerprinting' tests have been developed, one using an inert and the other an oxidizing atmosphere. These tests have been named evaporation profile and burning profile. 4 refs.
New and improved camouflage techniques which will enhance field security are required by Department of Army personnel. The report contains the results of tests, formulations and the operational characteristics of the 73E01-1A dispenser. Various tests (air...
We prepared polyclonal antibody specific to Mycoplasma pneumoniae and examined the conditions influencing the ability of an indirect immunofluorescence test to detect the specific antigen in respiratory...Full Text Available
There is no gold standard diagnostic test for the detection of bovine cryptosporidiosis. Infection is usually highest in 2-week-old calves, and these calves also excrete high numbers of oocysts. These...Full Text Available
This report covers the test methods and equipment for testing aircraft armor both hard and soft. The hard armor are the typical ceramic type while the soft armor are various types of layered composite materials. 10 figs. (JEF)
Sensitivity and specificity measure inherent validity of a diagnostic test against a gold standard. Researchers develop new diagnostic methods to reduce the cost, risk, invasiveness, and time. Adequate...Full Text Available
BackgroundFor the detection of allergen-specific IgE in sera, solid-phase IgE-binding assays like the CAP test are commonly used. Although such immunochemical methods are very sensitive,...Full Text Available
...visible damage. (k) Corrosion resistance. Each metal part of a...evidence of salt-spray corrosion resistance equal to or greater than...sample of test metal must show corrosion resistance equal to or better than...
Mitsubishi is now developing a new Pressurized water reactor (PWR), the Mitsubishi simplified PWR (MS-PWR), which has the innovative features of hybrid safety systems (an optimum combination of passive and active systems) and cooling by horizontal steam generators. In order to confirm the feasibility of the Mitsubishi hybrid safety system, various kinds of safety analyses are performed for loss-of-coolant accident events. In parallel to these safety analysis efforts, the following thermal-hydraulic tests are to be performed: (1) thermal-hydraulic test of a horizontal steam generator; (2) integrated thermal-hydraulic test using a simulation loop for the innovative MS-PWR (SLIM).
This is a slide-based oral presentation given to the COG/IAEA: Fifth technical committee meeting on 'Exchange of operating experience of pressurized heavy water reactors' held in Mangalia, Romania on 7-10 September 1998. Since energization of Wolsung Unit 3 station service transformer on July 12, 1996 a line of initial test program was conducted as follows: 1. ILRT/SIT; 2. Pre-operational and Hot Functional testing with a Light Water and without Fuel in Systems; 3. Load D_2O in Moderator System; 4. Initial fuel loading; 5. Load D_2O in PHT System; 6. Hot Functional Testing with Heavy Water and Fuel in Systems; 7. Criticality and Low Power Physics Testing; 8. Power Ascension Test and, then finally, phase-D test; the plant acceptance test was accomplished after having a Mini-Overhaul to prepare for Commercial Operation. These documents contain ...
A troubling reality in today's political climate is that many political leaders actually believe that the best way to change schools is through an "end of a gun barrel" approach, rather than by building consensus. In this article, the author examines the reality of high-stakes testing from several perspectives, including the politics of coercion, politics of performance, and the politics of perception. The author discusses that high-stakes testing is a politically charged issue that has had a tremendous impact on the way schools operate; however, teachers must not be afraid to keep their perspective and must encourage a healthy, honest dialogue about the role of testing and engage in political debate.
This paper summarises the main results obtained so far in the frame of the EU Home Team test programme of ITER primary wall small scale mock ups. It describes briefly the fabrication method of the mock ups, the test conditions and the main results obtained with high heat flux and thermal fatigue tests of Cu alloy/stainless steel and beryllium/Cu alloy/stainless steel mock ups. The results obtained so far show good thermal fatigue performance and operation margin of the ITER primary first wall concept. (author)
This paper describes the phenomenology of nuclear explosions and technologies for their detection as relevant to On-Site Inspection (OSI) for a comprehensive test-ban (CTB). Our experience with the US nuclear test program which has been primarily carried out at the Nevada Test Site (NTS) and in the Pacific Ocean. The goals of OSI are to resolve ambiguous events, reduce uncertainty, deter attempts at evasion, and provide responsive and technically competent means of confirming the occurrence of a nuclear explosion should deterrence fail. These goals would include finding evidence of an evasive nuclear explosion or evidence that the event was non-nuclear, such as an earthquake or large chemical explosion.
Criticality was first achieved with the Fast Flux Test Facility (FFTF) a little more than 10 yr ago on February 9, 1980. Although the FFTF was designed and built primarily for testing fuels, materials, and components for the liquid-metal fast breeder reactor program, it has, over its first 10 yr of operation, provided valuable information in many other areas. This paper provides a summary of the contributions to the physics of liquid-metal reactors (LMRs) obtained from operation of and testing in the FFTF, with emphasis on some of the more significant and interesting accomplishments.
System-level-operational testing of the ETX-II test-bed electric vehicle is described and the results discussed. Because the traction battery is a major factor in the performance of an electric vehicle, previously reported work on the sodium-sulfur battery designed for use with the ETX-II is reviewed in detail. Chassis dynamometer performance of the test-bed vehicle met or exceeded design goals and compared reasonably well with SIMPLEV computer modeling results. Areas are identified wherein further work is needed to establish a firmer basis for comparison of the simulation and the observed results.
Preliminary results of studies into penetrant testing at high surface temperature (up to 200 deg.C), are presented. Tests were performed to assess the effectiveness of red dye penetrants using Al and NiCr samples containing artificial as well as natural discontinuities. The test results will be used in due course to formulate a specification for non-destructive testing procedure qualification at non-standard (i.e. outside 16-52 deg.C) temperatures.
The principle is described of a method using low-activity emitters as the primary radiation source for analysis. The selection of the radiation source and the detection methods including the assessment of the applicability of various radiation detectors are discussed. The benefits and the constraints of the method are considered. Practical examples are presented showing the application possibilities of the method for testing the thickness of bearing layers, piston ring coats, lead layers, etc. The possibility is shown of applying the rapid test for the composition of tungsten and chromium alloyed metal materials in testing complex systems. (J.K.).
The repeated use and limited lifetime of a composite tiring vessel compel a need to survey techniques for monitoring the structural integrity of the vessel in order to determine when it should be retired. Various nondestructive techniques were researched and evaluated based on their applicability to the vessel. The methods were visual inspection, liquid penetrant testing, magnetic particle testing, surface mounted strain gauges, thermal inspection, acoustic emission, ultrasonic testing, radiography, eddy current testing, and embedded fiber optic sensors. It was determined that embedded fiber optic sensor is the most promising technique due to their ability to be embedded within layers of composites and their immunity to electromagnetic interference.
A nonlinear dynamic transient analysis merging hand calculations and the NASTRAN structural analysis computer code was conducted for a Fast Flux Test Facility in-reactor test assembly during an extremely unlikely design basis accidental event which is considered a Hypothetical Core Disruptive Accident (HCDA). The finite element modeling of the problem took advantage of NASTRAN's versatility to create loads and nonlinear elements not previously found in NASTRAN's library. The structural criteria for the test assembly to withstand an HCDA stipulates that the test assembly and its spoolpiece shall remain integral with the reactor head such that missiles are not generated.
This paper presents the main achievements of the European Home Team (EU HT) test programme of ITER primary wall small scale mock ups. It describes briefly the fabrication method of the mock ups, the test conditions and the main results obtained with high heat flux and thermal fatigue tests of Cu alloy/stainless steel and beryllium/Cu alloy/stainless steel mock ups. The results obtained so far show very good thermal fatigue performance and operation margin of the ITER primary first wall concept.
... from theory to practice will be significantly reduced while intrinsically revolutionizing the approach to engineering network security architectures. ...
Subsurface conditions at sites in the coastal plains region of South Carolina were investigated using standard penetration and mechanical quasi-static cone penetration tests. The penetration test results are compared with measured static axial pile capacity. The cone penetration test results are compared with stratigraphy and soil types encountered at each site. Results show that with certain limitations, cone penetration test results can be used to assess general stratigraphy and soil type and predict static axial pile capacity with reasonable accuracy.
The susceptibility to intergranular corrosion of different heats of Alloy 800 was evaluated by three different methods: the ASTM A 262 Practice E (or modified Strauss test), the Electrochemical Potentiokinetic Reactivation method, and by magnetic-susceptibility measurements. Reasonably good agreement was found between the sensitization areas as defined by the three methods in the TTS diagrams. In some cases the area defined by the Strauss test was slightly smaller than that determined by the other two tests. The differences might be explained by the fact that the methods present different sensitivities to the chromium concentration at the grain boundaries. 27 references, 11 figures, 3 tables.
This standard describes the procedure and equipment for in-place testing of HEPA filter systems by the single-particle, particle-size (SPPS) spectrometer method. This method provides the capability for evaluating the effectiveness (i.e., decontamination factor or DF) of systems consisting of one or more stages of HEPA filters against submicrometer aerosols in discrete particle-size ranges. It is particularly useful for testing of multi-stage HEPA filter installations and for testing of very large (50,000 cfm installed capacity) single-stage systems where it is desired to minimize the quantity of challenge aerosol required.
A large number of fiber optic cables were used in support of a neutron imaging experiment at the Nevada Test Site. This paper describes the quality control testing of fiber components used on this experiment. The principal reason for quality control testing was to ensure reliable, high transmission fibers; a secondary reason was to gain data on a large sample of fiber cables in the field. Also described is the instrumentation developed for carrying out these field measurements. The design of the quality control instrumentation was a compromise between accuracy and simplicity of use.
The thermal-hydraulic tests for a horizontal steam generator of a next-generation PWR (New PWR-21) were performed. The purpose of these tests is to understand the thermal-hydraulic behavior in the secondary side of horizontal steam generator during the plant normal operation. A test was carried out with cross section slice model simulated the straight tube region. In this paper, the results of the test is reported, and the effect of the horizontal steam generator internals on the thermal-hydraulic behavior of the secondary side and the circulation characteristics of the secondary side are discussed. (author)
The thermal-hydraulic tests for a horizontal steam generator of a next-generation PWR (New PWR-21) were performed. The purpose of these tests is to understand the thermal-hydraulic behavior in the secondary side of horizontal steam generator during the plant normal operation. A test was carried out with cross section slice model simulated the straight tube region. In this paper, the results of the test is reported, and the effect of the horizontal steam generator internals on the thermal-hydraulic behavior of the secondary side and the circulation characteristics of the secondary side are discussed. (author).
The SY-101 Equipment Removal System 100 Ton Hydraulic Trailer was designed and built by KAMP Systems, Inc. Performance of the Acceptance Test Procedure at KAMP`s facility in Ontario, California (termed Phase 1 in this report) was interrupted by discrepancies noted with the main hydraulic cylinder. The main cylinder was removed and sent to REMCO for repair while the trailer was sent to Lampson`s facility in Pasco, Washington. The Acceptance Test Procedure was modified and performance resumed at Lampson (termed Phase 2 in this report) after receipt of the repaired cylinder. At the successful conclusion of Phase 2 testing the trailer was accepted as meeting all the performance criteria specified.
The author describes the purpose, classification and main process of acceptance test of full scope simulator of Daya Bay Nuclear Power Plant, including the correction of non-conformance items which are discovered during the performance of acceptance tests. The results of the acceptance tests show that the model accepted by the full scope simulator of Daya Bay Nuclear Power Plant is fully able to cope with the simulation of normal transients and incidental transients and the performance of the simulator indeed compiled with the technical specifications which are defined n the relevant contracts.
The Wind Energy Division at Sandia National Laboratories recently completed a point design based on the 34-m Vertical Axis Wind Turbine (VAWT) Test Bed. The 34-m Test Bed research machine incorporates several innovations that improve Darrieus technology, including increased energy production, over previous machines. The point design differs minimally from the Test Bed; but by removing research-related items, its estimated cost is substantially reduced. The point design is a first step towards a Test-Bed-based commercial machine that would be competitive with conventional sources of power in the mid-1990s.
In order to reduce the potential for severe liquid pipeline accidents, the U.S. Materials Transportation Bureau (MTB) proposes to require a hydrostatic test on all onshore pipelines carrying highly volatile liquids which have not been previously tested to at least 1.25 times their maximum operating pressure for at least 24 hr. Comments should be received by the MTB by 2/15/79. Late filed comments will be considered as far as practicable.
Significant temperature differences occur between the internal structure and the outer skin of the Space Shuttle Orbiter as it returns from space. These temperature differences cause important thermal stresses. A finite element model containing thousands of degrees of freedom is used to predict these stresses. A ground test was performed to verify the prediction method. The analysis and test results compare favorably. (orig.).
LEDF (Large Equipment Dismantling Facility) will be constructed for the purpose of decontaminating the high level {alpha} solid waste generated in oarai engineering center of JNC. And, main processing process of LEDF is incineration and melting system. LEDF will be intended to reduce the secondary waste that occurs along with the operation of the off gas processing equipment of incineration and melting system. It assumed that we are able to eliminate the adsorption tower using silica gel, if the decontamination factor to volatile ruthenium is able to expect in the packed scrubber that is established to remove harmful gas. Thereupon, we carried out this tests that eliminates the adsorption tower and reduces the secondary waste. The decontamination factor (DF) to the volatile ruthenium by the water scrubber is confirmed in the established institution which is in Tokai Works. However, decontamination factor differs and depends on the ruthenium concentration, harmful ...
LEDF (Large Equipment Dismantling Facility) will be constructed for the purpose of decontaminating the high level #alpha# solid waste generated in oarai engineering center of JNC. And, main processing process of LEDF is incineration and melting system. LEDF will be intended to reduce the secondary waste that occurs along with the operation of the off gas processing equipment of incineration and melting system. It assumed that we are able to eliminate the adsorption tower using silica gel, if the decontamination factor to volatile ruthenium is able to expect in the packed scrubber that is established to remove harmful gas. Thereupon, we carried out this tests that eliminates the adsorption tower and reduces the secondary waste. The decontamination factor (DF) to the volatile ruthenium by the water scrubber is confirmed in the established institution which is in Tokai Works. However, decontamination factor differs and depends on the ruthenium concentration, harmful ...
Clostridium difficile (C. difficile) causes 25-30% of cases of antibiotic associated diarrhea and most cases of pseudomembranous colitis. Patients presenting with diarrhea after hospitalization for 3 or more days should be tested for C. difficile. There are many options available for testing, each of which has inherent advantages and disadvantages. Most laboratories perform toxin testing using an enzyme immunoassay method. In general these tests have sensitivities ranging from 60 to 70% and specificities of 98%. When using these methods, symptomatic patients with negative tests should be tested by another more sensitive method. Until recently, cell culture cytotoxicity neutralization assays (CCNAs) were considered the gold standard in the U.S. A two-step algorithm using an EIA for glutamate dehydrogenase detection followed by testing ...
The motion of a test particle moving in an interior static spherically symmetric geometry is investigated. The author concludes that an oscillatory motion with the test particle changing its motion from a free fall towards the center to an outward radial motion can not exist for any static interior spherically symmetric model.
A LOss of Electric Power(LOEP) experiment was conducted after a 30MW full power operation as one of the reactor performance tests to verify the design characteristics of the HANARO. The objective of LOEP test was to investigate the integral behaviors of the system and the components as well as the cooling characteristics when the electric power was lost unexpectedly. Through the test, it was confirmed that the residual heat from the core was safely removed by the natural convection cooling and the assistant power systems operated normally
This multinational, multi-phase spent fuel sabotage test program is quantifying the aerosol particles produced when the products of a high energy density device (HEDD) interact with and explosively particulate test rodlets that contain pellets of either surrogate materials or actual spent fuel. This program has been underway for several years. This program provides data that are relevant to some sabotage scenarios in relation to spent fuel transport and storage casks, and associated risk assessments. The program also provides significant technical and political benefits in international cooperation. We are quantifying the Spent Fuel Ratio (SFR), the ratio of the aerosol particles released from HEDD-impacted actual spent fuel to the aerosol particles produced from surrogate materials, measured under closely matched test conditions, in a contained test chamber. In addition, we are measuring the amounts, ...
This research activity emphasizes the systems definition and resulting structural requirements for the primary structure of two potential SPS large space structure test articles. These test articles represent potential steps in the SPS research and technology development.
Motivation is given for a technique to more thoroughly test semiconductor equipment control systems. A description is given of a simulator-based control system testing technique. Potential benefits that could be realized by using this technique in the semiconductor industry as well as benefits documented by using this technique in other industries are described. Specific requirements for using the technique in the semiconductor industry are outlined. A summary of a survey of nine commercial simulation systems is given. Finally, the outcome of the survey is compared with the requirements for using the technique.
It is maintained that special features of FFTF make it an ideal system to test sodium boiling detection techniques by acoustic/neutronic methods and to test the response of acoustic/neutronic sensors to vibrations. It is shown that accumulated research results indicate that such tests in FFTF are feasible, predictable, promising and safe. (author).
In this paper we propose a method for construction of feed-forward neural classifiers based on regularization and adaptive architectures. Using a penalized maximum likelihood scheme, we derive a modified form of the entropic error measure and an algebraic estimate of the test error. In conjunction with optimal brain damage pruning, a test error estimate is used to select the network architecture. The scheme is evaluated on four classification problems. PMID:12662736
Correlation characteristics of quantum noise on the shadow radiation image (RI) of the object under nondestructive testing are studied. Mathematical model of RI occasional distortions is derived. The model takes into account the parameters of object under testing and of radiation beam by radiation quanta flux density. The results obtained can be used as a component in the process of investigation of various radiation testing systems
This report provides key information on the irradiation environment of the MONJU fuel tests MFA-1 and MFA-2 in the Fast Flux Test Facility (FFTF). This information includes the fission powers, neutron fluxes, sodium temperatures and sodium flow rates in MFA-I, MFA-2 and adjacent assemblies. It also includes MFA-1 and MFA-2 compositions as a function of exposure. The work was performed at the request of Power Reactor and Nuclear Fuels Corporation (PNC) of Japan.
This report describes a high explosives test facility that makes efficient use of equipment and combines utility, convenience, and safety in a modest amount of space. It is a dedicated facility for exploratory development efforts that previously were conducted in a single room having very limited capabilities. Two explosives testing areas are now available and several projects are supported concurrently.
HEDL is conducting an experimental transient testing program to evaluate the performance of prototypic Fast Flux Test Facility (FFTF) fuel pins up to the cladding integrity limit. The relationship is described of the HEDL/TREAT transient overpower test program to the confirmation of FFTF fuel pin design bases via the FFTF fuel pin design procedure.
The Fast Flux Test Facility on the federal reservation at Hanford, Washington, has become a bright star in the universe of nuclear science and engineering technologies. The entire FFTF enterprise is now a success story, and this is particularly significant in these days when good news about nuclear power is scarce. The reactor, its testing capabilities and associated test facilities are described.
The sensitivity and specificity of the MGIT TBc identification (TBc ID) test for Mycobacterium tuberculosis complex (MTC) detection in positive Bactec MGIT cultures were 95.2% and 99.2%, respectively. When MTC-positive results obtained from two additional molecular methods were included, the sensitivity of the MGIT TBc ID test was 85.4%, while that of culture was 95.7%. PMID:21450949
An electrical circuit testing device is provided, comprising a case, a digital voltage level testing circuit with a display means, a switch to initiate measurement using the device, a non-shorting switching means for selecting pre-determined electrical wiring configurations to be tested in an outlet, a terminal block, a five-pole electrical plug mounted on the case surface and a set of adapters that can be used for various multiple-pronged electrical outlet configurations for voltages from 100 600 VAC from 50 100 Hz.
It is shown that bending tests on microsamples can be used to study the conditions in which hydrogen brittleness develops. In such tests hydrogen brittleness develops in the VTI5 alloy within the temperature range +5 to -20"0C. The tendency of VTI5 to develop hydrogen brittleness is enhanced with bending in salt water. (author).
Dispersants have been widely used as a primary response measure for marine oil spills around the world. Recently, the U.S. Environmental Protection Agency (EPA) developed an improved laboratory dispersant testing protocol, called the Baffled Flask Test (BFT). The BFT protocol w...
The objective of the program is to develop a domestic cooktop with low NOx emissions and higher efficiency. During the first phase of the program, a developmental prototype incorporating four IR-Jet burners was assembled. The report describes the work performed during the second phase of the program and covers optimization, and testing of the developmental prototype and design, fabrication and testing of the field-test prototype.
In this first quarterly technical report for DOE Contract No. DE-AC22-87PC79654, a description of the background, technology, and application is provided. The design and fabrication of advanced combustion chambers were completed during this period. Initial testing on both the bare metal and refractory lined advanced chambers were initiated. The units were tested initially with gas but primarily with coal. A Pittsburgh No. 8 pulverized coal was used for these test activities. Both advanced chambers pulsed well.
Using an experimental pilot plant, designed and built for the tests, the influence of the following parameters was determined: desulphurization of the test gas, temperature, residence time in the reactor tube, concentration of the hydrogen sulphide and desulphurization agent, size of the particles which comprise the agent and composition of the gas. Allowance was made for the effect of calcination and carbonisation. Desulphurization was carried out with limestone on a gaseous mixture of CO and H/sub 2/. A mathematical description of the test findings and yield is presented. 8 refs.
Despite the long track record of the technology, wood composite has rarely been applied to blades of this scale or for tip braked stall-regulated rotors. This paper describes how the design has been taken successfully from the concept to design through structural testing, certification and operational testing of the prototype set. (orig.)
A design concept is presented for an in-bundle gamma densitometer system for measurement of subchannel average fluid density and void fraction in rod or tube bundles. This report describes (1) the application of the design concept to the Thermal-Hydraulic Test Facility (THTF) electrically heated rod bundle; and (2) results from tests conducted in the THTF.
Qualifying corrosion inhibitors for use in high velocity multiphase flowlines in arctic or subsea environments is discussed. The tests include high velocity flow loop corrosion tests, pumpability through 0.125 (0.318 cm) inch capillary at low temperatures, compatibility with Nylon 11, emulsion tendency testing, and partitioning characteristics. Laboratory and field data show the importance for using the above criteria for inhibitor selection.
Government should model good practice in social inclusion and diversity.Apply a social inclusion test ...Government should model good practice in social inclusion and diversity.Apply a social inclusion test ...Government should model good practice in social inclusion and diversity.Apply a social inclusion test
Multiple-breath nitrogen washouts (MBNW) were performed with 21 adult dairy cows (seven normal cows tested on two days each, four clinically normal cows tested on six days, and ten cows with respiratory...Full Text Available
We provide a detailed overview of an ongoing, multinational test program that is developing aerosol data for some spent fuel sabotage scenarios on spent fuel transport and storage casks. Experiments are being performed to quantify the aerosolized materials plus volatilized fission products generated from actual spent fuel and surrogate material test rods, due to impact by a high energy density device, HEDD. The program participants in the U.S. plus Germany, France, and the U.K., part of the international Working Group for Sabotage Concerns of Transport and Storage Casks, WGSTSC have strongly supported and coordinated this research program. Sandia National Laboratories, SNL, has the lead role for conducting this research program; test program support is provided by both the U.S. Department of Energy and Nuclear Regulatory Commission. WGSTSC partners need this research to better understand potential radiological impacts from ...
The testing of candidate fuel elements at prototypic operating conditions with respect to temperature, power density, hydrogen coolant flow rate, etc., a crucial component in the development and qualification of nuclear rocket engines based on the Particle Bed Reactor (PBR), NERVA-derivative, and other concepts. Such testing may be performed at existing reactors, or at new facilities. A scoping study has been performed to assess the feasibility of testing PBR based fuel elements at the TREAT reactor. initial results suggest that full-scale PBR, elements could be tested at an average energy deposition of {approximately}60--80 MW-s/L in the current TREAT reactor. If the TREAT reactor was upgraded to include fuel elements with a higher temperature limit, average energy deposition of {approximately}100 MW/L may be achievable.
This paper addresses known limitations and constraints in eddy current nondestructive testing. Incomplete appreciation for eddy current limitations is believed to have contributed to both under-utilization and misapplication of the technique. Neither situation need arise if known limitations are recognized. Some, such as the skin depth effect, are inherent to electromagnetic test methods and define the role of eddy current testing. Others can be overcome with available technology such as surface probes to find circumferential cracks in tubes and magnetic saturation of ferromagnetic alloys to eliminate permeability effects. The variables responsible for limitations in eddy current testing are discussed and where alternative approaches exist, these are presented. Areas with potential for further research and development are also identified.
A sample of 30 manganese-exposed foundry workers from two Swedish plants were examined with a partly computerized psychological test battery, comprised of 10 performance tests. Performance of the manganese-exposed workers was compared to that of a matched control group of 60 workers. Matching criteria were age, geographical area, type of work, and the results on a test of verbal comprehension. Performance of the exposed workers was inferior to that of the control group on tests of simple reaction time, digit span, and finger tapping. No correlations were found between performance and the present manganese exposure levels or the number of years employed in manganese work. The results seem to indicate that the present exposure standards for manganese, in Sweden 2.5 mg/m3 and in most other countries 5 mg/m3, are not sufficient to protect workers from negative effects on performance capacity.
Cooling waters from eleven geographically disparate power plants were tested for the presence of Naegleria fowleri and Legionella pneumophila (LDB). Control source waters for each plant were also tested for these pathogens. Water from two of the eleven plants contained pathogenic Naegleria, and infectious Legionella were found in seven of the test sites. Pathogenic Naegleria were not found in control waters, but infectious Legionella were found in five of the eleven control source water sites. Concentrations of nitrite, sulfate, and total organic carbon correlated with the concentrations of LDB. A new species of Legionella was isolated from one of the test sites. In laboratory tests, both Acanthamoeba and Naegleria were capable of supporting the growth of Legionella pneumophila.
We have discovered a previously unidentified thermal explosion mode using the Los Alamos deflagration cylinder test (DFCT). The DFCT is a "pipe bomb"-style test similar to the detonation cylinder test (DTCT), which has been used for many years to calibrate detonation product equations of state. The shot is heated in an oven to a uniform test temperature. The pre-heated high explosive (HE) is triggered by a hot wire initiator on one end. The tube is back-illuminated by a bright light source, and its combustion-driven deformation and subsequent break-up are observed by a high-speed framing camera. Like the DTCT, the DFCT tube wall motion provides the primary diagnostic. A variety of reactive responses are possible, including quasi-steady deflagration and deflagration-to-detonation transition...
Background. A 19-year-old girl was diagnosed with systemic lupus erythematosus, based on findings of arthritis, malar rash, positive antinuclear antibody test and high levels of antibodies to double-stranded DNA. Two months after diagnosis, the patient presented with a sudden drop in blood hemoglobin level. Several days later, she developed bloody sputum, rapidly progressive dyspnea and hypoxemia. High-resolution CT showed diffuse alveolar infiltrates in both lung fields.Investigations. Physical examination, complete blood count, erythrocyte sedimentation rate, urinalysis, 24-h urine protein excretion, fecal occult blood test, d-dimer test, acid hemolysis test, activated partial thromboplastin time and prothrombin time, direct and indirect Coombs tests, bone marrow smear, arterial blood ga...
In January of 1977 the Paraho Development Company under contract with the United States Navy began a semi-works project to produce and refine up to 100,000 barrels of crude shale oil. Although the primary objective of the project was to produce specification turbine and diesel transportation fuels for field testing by the military field testing, the full-scale refinery run also produced a substantial quantity of hydrotreated shale oil residue. In 1978 the Electric Power Research Institute, recognizing the utilization potential of this material as a fuel for utility combustion turbines, obtained 4300 barrels of the residual shale oil product for future field testing. This report describes the processes involved in producing, handling, and storing the residual shale oil test material. The report also includes detailed chemical and physical analyses of the test material. In addition, ...
Objectives(1) Evaluate various insitu techniques for determination of the permeability of slurry walls and investigate the extent of material disturbance and fracturing during drilling and testing.~%~~%~(2) Perform laboratory tests of block samples obtained from the field testing site and compare the results with field measurements.~%~~%~(3) Investigate the mechanisms of drilling using a newly developed instrumented self-boring device and develop a theoretical framework for drilling mechanisms in soils.~% [continued...]DescriptionCement-bentonite and clay liner systems are used as components of containment systems by the environmental industry to control the migration of pollution. In the interest of public safety, following construction, there is a requirement to test these structures in orde to assess if they meet the design critetia. At present this is done only ...
Fuel Management at the Fast Flux Test Facility (FFTF) involves more than just the usual ex-core and in-core management of standard fuel and non-fuel components between storage locations and within the core since it is primarily an irradiation test facility. This mission involves testing an ever increasing variety of fueled and non-fueled experiments, each having unique requirements on the reactor core as well as having its own individual impact on the reload design. This paper describes the fuel management process used by the Westinghouse Hanford Company Core Engineering group that has led to the successful reload design of nine operating cycles and the irradiation of over 120 tests.
This paper presents experimental and analytical results of pipe whip tests performed under PWR LOCA conditions using a test pipe of 4-inch diameter and U-shaped restraints. In the tests, the effects of the overhang length on the pipe whip behavior of the piperestraints system were studied by measuring the strains and deformations of the test pipe and restraints, and the restraints forces. The equation for predicting the maximum strain at the outer surface of the pipe was derived using a static equilibrium condition. The calculated maximum strains at the outer surface of the pipe agree fairly well with experimental data. The dynamic response analysis of the pipe-restraints system was conducted by the finite element program ADINA. The applicability of the ADINA program to the pipe whip analysis is made clear through this analysis.
Emergency Core Cooling System (ECCS) is a safety critical system provided to mitigate the consequence of Loss of Coolant Accident (LOCA) in PHWR. Unlike 220MWe, all header injection has been introduced in 540MWe to simplify the logic. ECCS Integrated Test is schematic approach to establish that ECC system will behave as per design intent during actual LOCA condition. Objective of ECCS Integrated test is to ascertain that various ECC system components operate as intended in design. Additionally, the various system resistances which form the input to LOCA analysis are validated. This test has been carried out by creating actual LOCA during cold and pressurised condition of PHT system to establish all phases of injection with overlap. This paper discusses the results obtained during the Integrated Test and comparison with the prediction during the commissioning of first unit of 540 MWe. (author)
This paper presents the results of the dynamic response analysis of the pipe-restraints system by the general purpose finite element program ADINA. The analysis was carried out for the pipe whip tests performed under the PWR-LOCA conditions using 4-in. test pipe. In the analysis, the test pipe was modeled by an assemblage of the beam elements with the isotropic elastic-plastic material properties and the restraints were represented by the truss elements with the nonlinear elastic material properties including gap effect. The following results are obtained through the analysis. (1) Pipe can be modeled with the beam elements, when the overhang length is short and, therefore, the flattening of a cross-section of pipe is small. (2) The steady state restraint force can be predicted by modeling the restraints with the truss elements.
Development testing has been conducted by Rockwell Hanford Operations (Rockwell) with simulated Fast Flux Test Facility (FFTF) Reactor fuel and unirradiated N-Reactor fuel, to identify the various problems associated with rotary shearing these fuels. This report discusses the results of tests segmenting FFTF and N-Reactor fuels using electrically driven slow-speed rotary shredders. From these tests, it has been determined that slow-speed rotary shredding of both fuels can be accomplished. Final equipment arrangements and operating parameters have been established for definitive design of the FFTF Rotary Shear. Development testing is continuing on the N-fuel rotary shear. However, it has been established that two-stage shearing is necessary and the outer N-fuel elements pose few problems, while the smaller inner elements have created numerous problems, which are being addressed.
Development of the engineering technology basis of pyrometallurgical reprocessing is a key issue for industrialization. For development of the transport technologies of molten salt and liquid cadmium at around 773 K, a salt transport test rig and a metal transport test rig were newly installed in an Ar glove box. Function of the salt transport test rig was confirmed with LiCl-KCl molten salt, and the transport behaviour of molten salt was found to follow that of water. The molten salt/liquid metal contactor for Ln/An separation was newly designed and installed. The test with a single-stage contactor was successful with simulated elements, and a three-stage contactor is now under development. A large-scale electro-refiner with a function to transport molten salt and liquid cadmium were newly designed, and to be installed for demonstration test with simulated materials. (authors)
A dry interim storage facility has been constructed at the Wolsung power plant in Korea. This dry storage facility has seven separated modules. There are 40 long slender cylinders in one module. In one cylinder, ten baskets where sixty CANDU spent fuel bundles are loaded are stacked and stored. For this dry storage facility, analyses and tests for hypothetical accident conditions that might occur while moving and storing the baskets into a cylinder were performed. In a demonstration test, one of test basket models did not satisfy one of the safety-related requirements. Thus, the revised basket designs were generated using a structural evaluation based on finite element analyses and specimen tests. Among these revised designs, one design was chosen as a final revised basket design. The fina...
We are developing a refuelable zinc/air battery (6-cells) for evaluation under the five USABC `core` test protocols. In the first half of the two year project ($1OOK, FY1997), an advanced refuelable design was developed, fabricated and tested at power levels up to 415 W. Performance matched or exceeded that of earlier multicell systems. A computer program was developed for automated data acquisition and drive cycle simulation. Small mockup cells (80 cm 2) were constructed for rapid testing of components. In the follow-on effort (FY1998, $1OOK) we will make minor advances in system design and fabrication efficiency, and seek to improve cathode performance and life, before delivery of two final units for test at DOE laboratory.
The purpose of this study was to compare cardiopulmonary fitness and endurance in 9-11-year-old children with DCD against a group of typically developing children in Taiwan. The Movement ABC test was used to evaluate the motor abilities of children. Forty-one participants (20 children with DCD and 21 children without DCD) were recruited for this study. The cardiopulmonary tests included the 800-m run test and the peak oxygen consumption (peak VO2) test using the Bruce treadmill protocol. No significant differences in age, body height, body weight, body mass index, and percentage of body fat between children with DCD and without DCD were found. However, there were significant differences in the cardiopulmonary endurance tests between children with DCD and without DCD. Children with DCD had ...
The alloy type 'alloy 800' with its different variants is used for numerous components in high-temperature reactor (HTR) plants, e.g. for hot-gas conductors, the high-pressure part of steam generators, superheaters, steam collecting vessels and live steam conductors. This study deals with the evaluation of creep rupture tests on 28 welded joints of alloy 800 with an accumulated test duration of 410 years, with the objective to obtain quantitative information on a possible loss of strength in comparison with the unwelded material. The longest test period of an individual test amounted to 98,000 h and the analyzed test temperature range lay between 550"0 and 1000"0C. (orig./MM).
Commonly used EV battery tests are not very suitable for testing hybrid vehicle batteries, which may be primarily intended to supply vehicle acceleration power. The capacity of hybrid vehicle batteries will be relatively small, they will typically operate over a restricted range of states-of-charge, and they may seldom if ever be fully recharged. Further, hybrid propulsion system designs will commonly impose a higher regeneration content than is typical for electric vehicles. New test methods have been developed for use in characterizing battery performance and life for hybrid vehicle use. The procedures described in this paper were developed from the requirements of the government-industry cooperative Partnership for A New Generation of Vehicles (PNGV) program; however, they are expected to have broad application to the testing of energy storage devices for hybrid vehicles. The most important ...
Pipe whip tests or jet discharge tests have been performed at the Japan Atomic Energy Research Institute, which simulate the instantaneous circumferential guillotine break of primary coolant piping in nuclear power plants. The present paper describes the results of the pipe whip tests using test pipes of 4 inch diameter, under the BWR LOCA conditions, which were performed from 1979 to 1981. The tests were carried out at an initial pressure of about 6.8 MPa and an initial temperature of about 285/sup 0/C. The test pipe was 114.3 mm (4 in) in diameter, 8.6 mm in thickness and 4500 mm in length. The four pipe whip restraints used in the tests were the U-bar type of 8 mm in diameter and frabricated from Type 304 stainless steel. The experimental parameters were the clearance (30, 50 and 100 mm) and the overhang length (250, 400, 550 and 1000 ...
This paper describes the design of a test rig, which is used to apply a representative pressure load to a full-scale composite sandwich secondary aircraft structure. A generic panel was designed with features to represent those in the composite sandwich secondary aircraft structure. To provide full-field strain data from the panels, the test rig was designed for use with optical measurement techniques such as thermoelastic stress analysis (TSA) and digital image correlation (DIC). TSA requires a cyclic load to be applied to a structure for the measurement of the strain state; therefore, the test rig has been designed to be mounted on a standard servo-hydraulic test machine. As both TSA and DIC require an uninterrupted view of the surface of the test panel, an important consideration in the design is facilitating the optical access for the two techniques. To aid the ...
Machine condition monitoring (MCM) has the capability to predict equipment maintenance needs which can reduce forced down-time and facilitate the avoidance of catastrophic failures and the consequential secondary damage. It can be used to allow confident deferral of routine maintenance, and improve equipment performance, availability, reliability and safety. In order to capitalize on the potential benefits of MCM directed toward power transformers two types of vibration tests were conducted on transformers owned and operated by Cargill Inc. and IES Utilities at the Bridgeport corn plant in Eddyville, Iowa. These tests involved collecting vibration signals from the transformer tank walls during transformer energization at no-load and during steady state operation at various loads. These vibration signals were then used to detect deterioration of internal mechanical integrity. Both types of tests conducted on the transformers ...
Uniaxial low-cycle fatigue and creep-fatigue tests have been carried out on hollow alloy 800 specimens that were filled with steam. Two testing temperatures were employed, each with its own steam condition. These temperatures and steam conditions were 650/sup 0/F with saturated steam (5% liquid, 95% vapor) and 1200/sup 0/F with superheated steam at 2200 psi. The low-cycle fatigue tests were carried out at both 650/sup 0/F and 1200/sup 0/F by cycling the strain between equal tensile and compressive magnitudes until specimen failure or until it was no longer practical to continue the test. The creep-fatigue tests were carried out to failure by cycling the strain in the same fashion as in the low-cycle fatigue tests but with holds imposed at either the peak tensile strain or the peak compressive strain or at both peak tensile and compressive strains in each loading ...
Fourteen irradiated Fast Flux Test Facility (FFTF) fuel pins were subjected to representative overpower transients in six flowing sodium loop experiments conducted in the TREAT reactor. The transient tests were extended to substantial overpower levels well beyond protected levels, with some tests intentionally run to failure to identify failure thresholds and characteristics. Test variables included transient ramp rate (5, 50, and 100 cents/s) and burnup (2 to 58 MWd/kg). Performance limits and failure characteristics were identified, and cladding strain and fuel melting data were obtained for development and verification of transient analysis codes. The test results demonstrated that FFTF Reference fuel pins are capable of surviving overpower levels well beyond the FFTF secondary Plant Protection System (PPS) trip limit of 1.25 times normal rated power. Based on analytical ...
Based on an multivariate statistical evaluation of binary and metric data relating to the soil cover of the European Community five regionally representative reference soils (EURO-Soils) have been identified for chemicals testing in the EC. The soil material sampled at representative localities in Italy, Greece, Great Britain, France and Germany was treated and prepared according to OECD Test Guideline 106 and analysed in detail. The homogenised specimens were subject to an EC-wide ring test to evaluate the feasibility of the modified guideline and to validate the physical-chemical amenability of the reference soils for sorption tests. The results proved the validity of the soils selected for assessing the potential behaviour of new chemicals in soil on the basis of a comparative evaluation of the individual test results obtained. In the light of this parametric assessment potential ...
Commercially available melter technologies were tested during 1994-95 as part of a multiphase program to test candidate technologies for vitrification of the low-level waste (LLW) stream to be derived from retrieval and pretreatment of Hanford Site tank wastes. Seven vendors were selected for Phase 1 testing to demonstrate vitrification of a high sodium content liquid LLW simulant. The tested melter technologies included four Joule-heated melters, a carbon electrode melter, a combustion melter, and a plasma melter. Various dry and slurry melter feed preparation processes were also tested. Various feed material samples, product glass samples, and process offgas streams were characterized to provide data for evaluation of process decontamination factors and material mass balances for each vitrification technology. This report describes the melter mass balance evaluations and results ...
The insulating oil used in a transformer is a critical component, as its service life is typically 20 years with possibly little or no maintenance. Partial discharges (PD), thermal overloads and static discharges continually subject the oil to chemical deterioration during its operating life. To ensure equipment reliability during service, it is important that the initial quality of the new insulating oil should meet the required acceptance specifications and preferably be pre-tested before use. Accelerated aging tests have been devised to determine the life expectancy of oil in service by using forced air or oxygen flow into the oil, the presence of a copper catalyst, and at elevated temperatures. The more important standards relating to transformer application are discussed and highlights of the more important aspects of the oxidation chemistry of hydrocarbons are included. The ultimate aim of the project is the formulation of better standard ...
The research and development for the first year of the project are performed through specialization of researchers, information from aborad and international cooperation, securement of advanced nuclear technology, development and installation of test equipment, application of external man-power, establishment of advanced test techniques, and certified test method. 1. Absolute efficiency measurement examination technology development of gamma scanning system 2. Sample preparation technology development of SEM and EPMA for micro-structural observation and chemical composition analysis 3. Irradiated high burn-up nuclear fuel transportation and test for PWR 4. Development of hot cell examination techniques and equipment 5. Acquirement of KOLAS system. In addition to the project, the following activities are carried out as follows; - PIE of Hanaro fuel(KH99H-001) - PIE of U-Mo advanced nuclear fuel ...
Using a facility named SPHINX, which can accommodate a heat transfer test with CO{sub 2} at supercritical pressure, a series of tests was performed. The test geometries include tubes with the inner diameter of 4.4, 6.32 and 9 mm. a concentric annular passages with 8 x 10 mm, and an eccentric annular passages with 9.5 x 12.5 mm. Based on the test results, heat transfer correlations were developed and compared with the existing correlations. The heat transfer deterioration which may occur at certain conditions of heat and mass flux, were carefully studied and the published criteria were reviewed against our test results. Numerical calculation by using commercial CFD code, Fluent, were performed in order to provide the pre-test information for the heat transfer tests. Various turbulence models were evaluated and reliable models were suggested ...
A 25m wind turbine blade was tested to failure when subjected to a flapwise load. With the test setup, it was possible to test the blade to failure at three diffe-rent locations. The objective of these tests is to learn about how a wind turbine blade fails when exposed to a large flapwise load and how failures propagate. The report shows also results from ultra sonic scan of the surface of the blade and it is seen to be very useful for the detection of defects, especially in the layer between the skin laminate and the load carrying main spar. Acoustic emission was successfully used as sensor for the detection of damages in the blade during the test. The report contains measurements of the total deflection of the blade, the local deflection of the skin and the load carrying main spar and also measurement of strain all as a function of the applied load and up to failure of the blade. ...
The Fast Flux Test Facility (FFTF)is a 400 MW (th) sodium-cooled fast flux test reactor located on the Hanford Site in southeastern Washington State. The FFTF is operated by the Westinghouse Hanford Company for the United States Department of Energy. The FFTF is a three loop plant designed primarily for the purpose of testing full-scale core components in an environment prototypic of future liquid metal reactors. The plant design emphasizes features to enhance this test capability, especially in the area of the core, reactor vessel, and refueling system. Eight special test positions are provided in the vessel head to permit contact instrumented experiments to be installed and irradiated. These test positions effectively divide the core into three sectors. Each sector requires its own In-Vessel Handling Machine (IVHM) to access all the core positions. Since the ...
The constitutive model used to describe the deformation of crushed salt is presented in this report. Two mechanisms -- dislocation creep and grain boundary diffusional pressure solution -- are combined to form the basis for the constitutive model governing the deformation of crushed salt. The constitutive model is generalized to represent three-dimensional states of stress. Upon complete consolidation, the crushed-salt model reproduces the Multimechanism Deformation (M-D) model typically used for the Waste Isolation Pilot Plant (WIPP) host geological formation salt. New shear consolidation tests are combined with an existing database that includes hydrostatic consolidation and shear consolidation tests conducted on WIPP and southeastern New Mexico salt. Nonlinear least-squares model fitting to the database produced two sets of material parameter values for the model -- one for the shear consolidation tests and one for a ...
In this report, the descriptions of the DIVA test facility and those test matrixes are presented. The test sections simulate the downcomer annulus of DVI system with various scalling methodologies. The UPTF one has 1/7.5 scale and the APR-1400 test sections are reduced in 1/7 scale and 1/5 scale respectively. Also, the instrumentations, measuring methods are described. The major measuring parameters are ECC injection rate, air injection rate, bypass fraction, system pressure and so on. And finally, the operation procedure and experimental steps are introduced. From the DIVA tests, the multi-dimensional behaviors of two-phase flow in the downcomer during the reflood phase can be investigated using a transparent test facility. Also comparing the experimental data which are performed in various scale downcomer, it is expected that some criteria of scalling ...
This report describes a comparison result of technical standards applied to instrumentation and control systems for nuclear power plants between in Korea and in Russia. Russia also has a state-run organization authorized to conduct approval, cancellation, and audit in use of nuclear facility or equipment. The Russian standards for nuclear instrumentation and control equipment are analogous with the Korean ones in the aspect of basic concepts and principles. However, there are some differences in document structure, design requirements, qualification test items, depth of contents between two standard systems. The biggest deviation exists in the standard documents for seismic qualification and electromagnetic interference qualification. Korean seismic qualification standard utilizing US approach, defines testing and qualification methods specifically and clearly. Russian standards however provide only conceptual definitions and requirements in ...
The TRAC/PFI-MOD2 Version 5.3 code was assessed against six FLECHT-SEASET forced reflood tests (31504, 31203, 31302, 31701, 34209, and 31922) and two cylindrical core test facility (CCTF) tests [C1-19 and C2-6]. The objective of this study was to evaluate the clad thermal response predictive capabilities of the code with the newly added reflood model under large-break loss-of-coolant accident (LOCA) conditions in a pressurized water reactor (PWR). The TRAC model for the FLECHT-SEASET test facility was developed from a RELAP5 model. The test section was modeled using a vessel component with 23 axial levels, 1 radial ring, and 1 azimuthal cell. Test inlet and exit conditions were modeled using fill and break components, respectively. The measured lower and upper plenum test conditions were input to the model. The electrically heated rod was ...
Heat transfer tubes of a primary pressurized water cooled (PPWC) in the high temperature engineering test reactor (HTTR) form the reactor pressure boundary of the primary coolant, therefore are important from the viewpoint of safety. To establish inspection techniques for the heat transfer tubes of the PPWC, an automatic inspection system was developed. The system employs a bobbin coil probe, a rotating probe for eddy current testing (ECT) and a rotating probe for ultrasonic testing (UT). Nondestructive test of a half of the heat transfer tubes of the PPWC was carried out by the automatic inspection system during reactor shutdown period of the HTTR (about 55% in the maximum reactor power in this paper). The nondestructive test results showed that the maximum signal-to-noise ratio was 1.8 in ECT. Pattern and phase of Lissajous wave, which were obtained for the heat transfer tube of ...
The ability to test advanced fuels and cladding materials under reactor operating conditions in the United States is limited. The Oak Ridge National Laboratory (ORNL) High Flux Isotope Reactor (HFIR) and the newly expanded post-irradiation examination (PIE) capability at the ORNL Irradiated Fuels Examination Laboratory provide unique support for this type of advanced fuel/cladding development effort. The wide breadth of ORNL's fuels and materials research divisions provides all the necessary fuel development capabilities in one location. At ORNL, facilities are available from test fuel fabrication, to irradiation in HFIR under either thermal or fast reactor conditions, to a complete suite of PIEs, and to final product disposal. There are very few locations in the world where this full range of capabilities exists. New testing capabilities at HFIR have been developed that allow testing of ...
Acceptance testing of mammographic imaging systems technical is the first approach in order to guarantee that mammograms will be achieved with the minimum radiation dose compatible with an image quality suitable for diagnose purposes. The aim of this study is to assess the practical applicability of different protocols in acceptance test of digital mammographic systems. This study has been carried out on the results of the acceptance tests of five flat panel digital mammographic systems. Parameters established in the systems technical specifications and those evaluated in the consulted protocols were tested. Due to the fact that the legislation in our country does not demand to consider a specific protocol, the results obtained were also compared considering different existing protocols. Results show discrepancies between manufacturers limiting values and those established in the protocols. Some ...
The history of the urinary test papers does not being in the post-war period. As early as the 1880's some practitioners and pharmacists tried to replace the complicated wet-chemical procedures and apparatus by "dry chemistry." The first popular test paper for sugar and albumin originated in England in 1883. Dry reagents for proving hematuria have been available since the beginning of this century. Until the 1930s a wide palette of commercial urine tests with "modern" brand names was established. A methodological breakthrough was created by the spot test chemistry inaugurated by the Austrian, Fritz Feigl, about 1920. Using the capillary properties of filter paper in enhancing color reactions he founded a new area of analytical chemistry. Many of the pioneers were recruited from Jewish scientists. In this lecture is proposed that their emigration and banishment as well as the Second World War have stopped ...
Ultra High Vacuum (UHV) test setup for electron gun testing has been developed. The development of next generation light sources and accelerators require development of klystron as a radio frequency power source, and in turn electron gun. This UHV electron gun test setup can be used to test the electron guns ranging from high average current, quasi-continuous wave to high peak current, single pulse etc. An electron gun has been designed, fabricated, assembled and tested for insulation up to 80 kV under the programme to develop high power klystron for future accelerators. Further testing includes the electron emission parameters characterization of the cathode, as it determines the development of a reliable and efficient electron gun with high electron emission current and high life time as well. This needs a clean ultra high vacuum to study these parameters ...
Mitsubishi is now developing a next-generation Pressurized Water Reactor (PWR) which has the innovative feature of hybrid safety systems (optimum combination of passive safety system and active safety system) and passive core cooling by horizontal steam generators during Loss of Coolant Accident (LOCA). In order to confirm the capability of this passive core cooling system during LOCAs, the thermal-hydraulic tests of horizontal steam generator and the integral thermal-hydraulic tests simulating the LOCAs were performed. The thermal-hydraulic tests of horizontal steam generator consist of a single tube test and a multi-tubes test. On the basis of these test results, the heat transfer characteristics of steam-water two-phase flow with noncondensable gas along a long horizontal tube is understood and the heat transfer correlation including the effect of ...
The Korean Next Generation Reactor (KNGR) adopts 4-train Direct Vessel Injection (DVI) configuration and injects the safety injection water directly into the downcomer through the 8.5'' DVI nozzle. Thus, the thermal hydraulic phenomena such as ECCS mixing and bypass are expected to be different from those observed in the cold leg injection. In order to investigate the realistic injection phenomena and modify the analysis code developed in the basis of cold leg injection, thermal hydraulic test with the performance evaluation is required. Preliminarily, the sequence of events and major thermal hydraulic phenomena during the small break LOCA for KNGR are identified from the analysis results calculated by the CEFLASH-4AS/REM. It is shown from the analysis results that the major transient behaviors including the core mixture level are largely affected by the downcomer modeling. Therefore, to investigate the proper thermal hydraulic phenomena occurring ...
The Phebus FP project in an international reactor safety project. Its main objective is to study the release, transport and retention of fission products in a severe accident of a Light Water Reactor (LWR). The FPT4 test was performed with a fuel debris bed geometry, to look at late phase core degradation and the releases of low volatile fission products and actinides. Post Test Analyses results indicate that releases of noble gases (Xe, Kr) and high-volatile fission products (Cs, I) were nearly complete and comparable to those obtained during Phebus tests performed with a fuel bundle geometry (FPT1, FPT2). Volatile fission products such as Mo, Te, Rb, Sb were released significantly as in previous tests. Ba integral release was greater than that observed during FPT1. Release of Ru was comparable to that observed during FPT1 and FPT2. As in other Phebus tests, the Ru distribution ...
1 - Description of test facility: The LOBI facility is a 1/700 scale model of a four loop PWR and has two primary loops, the intact loop representing three loops and the broken loop representing one loop of a four-loop PWR. The reactor pressure vessel model contains an electrically heated rod-bundle with 64 rods and a heated length of 3.9 m. The nominal heating power is 5.3 MW. The downcomer is of annular shape. An upper head simulator is connected to the vessel. Each of the two primary loops contains a pump and a steam generator. The different mass flows in the loops are established by the pump speeds, since the two pumps are identical. Heat is removed from the steam generators by a secondary system. ECC water can be supplied from two accumulators, one for each loop. Cold or hot leg as well as combined injection can be simulated. The LOBI test facility is the only high pressure integral test facility within the European ...
The fluid-induced vibration level of instrumented capsule, which was manufactured for fuel irradiation test at the reactor core of HANARO, was investigated. For this purpose, the instrumented capsule was loaded at the OR site of the HANARO design verification test facility that could simulate identical flow condition as the HANARO core. Then, vibration signals of the instrumented capsule subjected to various flow conditions were measured by using vibration sensors. In time domain analysis, maximum amplitudes and RMS values of the measured acceleration and displacement signals were obtained. By using frequency domain analysis, frequency components of the fluid-induced vibration were analyzed. In addition, natural frequencies of the instrumented capsule were obtained by performing modal test. The frequency analysis results showed that the natural frequency components near 7.5Hz and 17.5Hz were dominant in the fluid-induced ...
There is increasing evidence that chemicals/test substances cannot only have adverse effects, but that there are many substances that can (also) have a beneficial effect on health. As this journal regularly publishes papers in this area and has every intention in continuing to do so in the near future, it has become essential that studies reported in this journal reflect an adequate level of scientific scrutiny. Therefore a set of essential characteristics of studies has been defined. These basic requirements are default properties rather than non-negotiables: deviations are possible and useful, provided they can be justified on scientific grounds. The 10 basic requirements for a scientific paper reporting antioxidant, antimutagenic or anticarcinogenic potential of test substances in in vitro experiments and animal studies in vivo concern the following areas: (1) Hypothesis-driven study design; (2) The nature of the test ...
This comprehensive, illustrated report for the Swiss Federal Office of Energy (SFOE) by the University of Applied Sciences in Lucerne, Switzerland takes a look at the testing facility at the university that is used to test compact ventilation systems. These feature heat-recovery and return-air heat-pumps and are used in housing built to low energy-consumption standards such as the Swiss 'Minergie' and 'Minergie-P' standards. The primary goal is a technically comprehensive testing programme for compact ventilation units with heat recovery and heat pumps, which can nevertheless be carried out at reasonable cost. In addition to thermal and flow measurements, acoustic measurements are also carried out. The authors quote that the overall assessment provided can also include service and maintenance, materials used and possible problems with thermal bridges. The test ...
Sandia National Laboratories has recently developed two major field test capabilities for unattended ground sensor systems at the Department of energy`s Nevada Test Site (NTS). The first capability utilizes the NTS large area, varied terrain, and intrasite communications systems for testing sensors for detecting and tracking vehicular traffic. Sensor and ground truth data can be collected at either of two secure control centers. This system also includes an automated ground truth capability that consists of differential Global Positioning Satellite (GPS) receivers on test vehicles and live TV coverage of critical road sections. Finally there is a high-speed, secure computer network link between the control centers and the Air Force`s Theater Air Command and Control Simulation Facility in Albuquerque NM. The second capability is Bunker 2-300. It is a facility for evaluating advanced sensor systems for ...
Polymers are required to use in radiation environments as insulation materials. However, they often suffer from tracking failure. There is an increasing demand to evaluate radiation effects on dielectric performance. This paper presents a recurrence plot (RP) approach to analyse surface discharge sequences of gamma-ray irradiated polymer materials based on tracking test. Studying the non-linear characteristics of discharge sequences can assist in understanding the underlying mechanism of the discharge process. Discharge sequences of the test are extended to m-dimensional phase space by using the phase space reconstructed method. As test samples, polybutylene terephthalate (PBT) and polybutylene naphthalate (PBN) were irradiated to 100 kGy and then up to 1 MGy with a dosage rate of 10 kGy h{sup -1} by using a {sup 60}Co gamma source. The tracking tests were carried out according to the ...
The development of turbine components for the automotive 100 kW ceramic gas turbine has entered the final stage of the seven-year project and is making satisfactory progress, toward the goals. The authors attained the interim targets of the aerodynamic performances and have been carrying out tests to further improve efficiency. As for ceramic parts, they have changed the material of the turbine rotor to a new one that is excellent in long-sustained and high-temperature strength properties, and have confirmed substantial strength at high temperature through hot-spin tests. After evaluating blade-vibration stress through analyses and experiments, the authors completed an endurance evaluation at 1200 C (1473 K) TIT (Turbine Inlet Gas Temperature) and a rated speed of 100,000 rpm. The authors are now carrying out endurance tests at 1350 C (1623 K) TIT. For ceramic stationary parts, they already finished the evaluations at 1200 ...
The objective of this study was to assess the feasibility for propane as an automotive fuel in Manitoba, by comparing the overall performance and operating costs of a test fleet operating on propane with that of a control fleet operating on unleaded gasoline. The performance of gasoline and propane was compared by using two specific tests: general driveability and relative fleet fuel consumption were determined by driver surveys and gross fuel use data from normal urban and rural vehicle operation. Specific fuel consumption was determined by controlled chassis dynamometer tests on a series of selected vehicles utilizing representative driving cycles. Fleet drivers operating propane fueled vehicles were satisfied with vehicle operation and reported similar vehicle performance with either gasoline or propane. Although there was no significant difference in specific fuel consumption, the specific energy consumption of similar ...
EPRI has sponsored an experimental program in the pipe whip impact and pipe rupture and depressurization areas. Sixteen pipe whip tests were performed with 3 in Schedule 80 (or 10) carbon steel pipes impacting on rigid target or concrete slab. The major testing parameters include distance, impact location, pipe rupture location, and concrete slab thickness and strength. The piping crushing at impact correlates with impact force and target response behavior. Conservatism was established by comparing measured and calculated impact forces. The pipe rupture and depressurization tests were carried out using 6 in stainless steel and carbon steel pipes under either PWR or BWR fluid conditions. These tests are of axial crack with initial machined-in surface flaw. It was found that pipe rupture would occur only if a long unstable through-wall crack was embedded in a sufficiently long unstable part-through crack ...
This proceedings is the compilation of papers presented at the ninth PV Performance and Reliability Workshop held at the Sheraton Denver West Hotel on September 4--6, 1996. This years workshop included presentations from 25 speakers and had over 100 attendees. All of the presentations that were given are included in this proceedings. Topics of the papers included: defining service lifetime and developing models for PV module lifetime; examining and determining failure and degradation mechanisms in PV modules; combining IEEE/IEC/UL testing procedures; AC module performance and reliability testing; inverter reliability/qualification testing; standardization of utility interconnect requirements for PV systems; need activities to separate variables by testing individual components of PV systems (e.g. cells, modules, batteries, inverters,charge controllers) for individual reliability and then ...
Nuclear power plant has several safety features and each safety feature is based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear power plant to keep operational readiness of pumps and valves by In-Service Test (IST). According to Ministry of Education, Science and Technology (MEST) Bulletin 2008-14, the safety functioned pumps and valves of all nuclear power plants of Korea Hydro and Nuclear Power Co. Ltd.(KHNP) have been tested to verify their performance of safety function. Each safety grade pump has own design requirement and should be tested to identify whether it could meet the requirement. Design requirements and test references of all safety grade pumps of Wolsung Nuclear Power Plant Unit 2 (Wolsung Unit 2) were examined in this study. And the results of the performance test of the pump were also compared to the design ...
Nuclear power plant has several safety features and each safety feature is based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear power plant to keep operational readiness of pumps and valves by In-Service Test (IST). According to Ministry of Education, Science and Technology (MEST) Bulletin 2008-14, the safety functioned pumps and valves of all nuclear power plants of Korea Hydro and Nuclear Power Co. Ltd.(KHNP) have been tested to verify their performance of safety function. Each safety grade pump has own design requirement and should be tested to identify whether it could meet the requirement. Design requirements and test references of all safety grade pumps of Wolsung Nuclear Power Plant Unit 2 (Wolsung Unit 2) were examined in this study. And the results of the performance test of the pump were also compared to the design ...
PANDA is a large scale facility for investigating the long-term decay heat removal from the containment of a next generation of 'passive' Advanced Light Water Reactors (ALWR). PANDA was used to examine the long-term LOCA response of the Passive Containment Cooling System (PCCS) for the General Electric (GE) Simplified Boiling Water Reactor (SBWR). The first PANDA test series had the dual objectives of demonstrating the performance of the SBWR PCCS and extending the data base available for containment analysis code qualification. The test objectives also include the study of the effects of mixing and stratification of steam and noncondensible gases in the drywell (DW) and in the suppression chamber or wetwell (WW). Ten tests were conducted in the course of the PANDA SBWR Program. The tests demonstrated a favorable and robust overall PCCS performance under different conditions. The present paper focuses ...
A testing program has been conducted by the Westinghouse Hanford Company to confirm the baseline waste form selection for use in Waste Receiving and Processing (WRAP) Module 2A. WRAP Module 2A will provide treatment required to properly dispose of containerized contact-handled, mixed low-level waste at the US Department of Energy Hanford Site in south-central Washington State. Solidification/stabilization has been chosen as the appropriate treatment for this waste. This work is intended to test cement-based, thermosetting polymer, and thermoplastic polymer solidification media to substantiate the technology approach for WRAP Module 2A. Screening tests were performed using the major chemical constituent of each waste type to measure the gross compatibility with the immobilization media and to determine formulations for more detailed testing. Surrogate materials representing each of the eight waste types ...
In the frame of the European Technology R and D program for ITER, and in the area of High Heat Flux plasma facing Components (HHFC), representative small-scale mock-ups were manufactured and tested to compare different concepts and joining technologies (i.e. active brazing, Hot Isostatic Pressing (HIPping), diffusion bonding, etc.). On the basis of the results obtained by thermal fatigue tests, the monoblock concept resulted to be the most promising one, particularly when the HIPping manufacturing technology is used. Within this program, ENEA manufactured tungsten monoblock mock-ups by using the HIPping technology. The mock-ups were tested with respect to thermal fatigue and, upon screening tests, the best performance obtained was 15 MW/m{sup 2} for 200 cycles. One of these mock-ups was enclosed in the 'Paride' neutron irradiation campaign. This campaign has the scope of enlarging the ...
In the frame of the European Technology R and D program for ITER, and in the area of High Heat Flux plasma facing Components (HHFC), representative small-scale mock-ups were manufactured and tested to compare different concepts and joining technologies (i.e. active brazing, Hot Isostatic Pressing (HIPping), diffusion bonding, etc.). On the basis of the results obtained by thermal fatigue tests, the monoblock concept resulted to be the most promising one, particularly when the HIPping manufacturing technology is used. Within this program, ENEA manufactured tungsten monoblock mock-ups by using the HIPping technology. The mock-ups were tested with respect to thermal fatigue and, upon screening tests, the best performance obtained was 15 MW/m"2 for 200 cycles. One of these mock-ups was enclosed in the 'Paride' neutron irradiation campaign. This campaign has the scope of enlarging the available database on ...
The LHC magnet tests operation team developed various innovative techniques, particularly since early 2004, to complete the superconductor magnet tests by Feb. 2007. Overall and cryogenic priority handling, rapid on-bench thermal cycling, rule-based goodness evaluation on round-the-clock basis, multiple, mashed web systems are some of these techniques applied with rigour for successful tests completion in time. This paper highlights these operation empowerment tools which had a pivotal role for success. A priority handling method was put in place to enable maximum throughput from twelve test benches, having many different constraints. For the cryogenics infrastructure, it implied judicious allocation of limited resources to the benches. Rapid On-Bench Thermal Cycle was a key strategy to accelerate magnets tests throughput, saving time and simplifying logistics. First level magnet ...
LOCA (Loss of coolant accident) resistant heat-shrinkable polymeric products are widely used for the connection of LV cables for class 1E systems inside the containment area of nuclear power plants. The paper/presentation describes the verification of a reformulated compound for these products, where certain components of the compound formulation had to be substituted. A qualification programme with this so-called reformulated compound was undertaken to proof the equivalency of the products to the products made out of the original compound. The basic elements of this requalification project were material qualification tests including accelerated aging tests according to the arrhenius method and type tests in accordance to IEEE 383, including flammability tests. The test results showed that the products made out of the reformulated compound were similar in fit, form and function to ...
Several U.S. Department of Energy organizations and the U.S. Bureau of Mines have been collaboratively conducting mixed waste treatment process demonstration testing on the near full-scale graphite electrode submerged arc melter system at the Bureau`s Albany (Oregon) Research Center. An initial test series successfully demonstrated arc melter capability for treating surrogate incinerator ash of buried mixed wastes with soil. The conceptual treatment process for that test series assumed that buried waste would be retrieved and incinerated, and that the incinerator ash would be vitrified in an arc melter. This report presents results from a recently completed second series of tests, undertaken to determine the ability of the arc melter system to stably process a wide range of {open_quotes}as-received{close_quotes} heterogeneous solid mixed wastes containing high levels of organics, representative of the ...
A 19.1 metre wind turbine blade was subjected to static tests. The purpose of the test series was to verify the abilities of different types of sensors to detect damage in wind turbine blades. Prior to each of the static test-series an artificial damage was made on the blade. The damage made for each test-series was surveyed during each series by acoustic emission, fiber optic micro bend displacement transducers and strain gauges. The propagation of the damage was determined by use of ultra sonic and X-ray surveillance during stops in the test series. By use of acoustic emission it was possible to measure damage propagation before the propagation was of visible size. By use of fiber optic micro bend displacement transducers and strain gauges it was possible to measure minor damage propagation. By use of both ultra sonic, and X-ray NDT-equipment it were possible to determine the size ...
Various electrochemical capacitors (ultracapacitors) are being developed for hybrid vehicles as candidate power assist devices for the fast response engine. The primary functions of the ultracapacitor are to level the dynamic power loads on the primary propulsion device and recover available energy from regenerative breaking during off-peak power periods. Ultracapacitors show promise toward being able to accept high regenerative pulses while exhibiting very high cycle life. This paper will present test data from selected US Department of Energy (DOE) supported ultracapacitor projects designed to meet the fast response engine requirements. Devices containing carbon, conducting polymers, and metal oxide electrode materials in combination with aqueous or organic electrolytes are being supported by the DOE. This paper will present and discuss testing data obtained from recent prototype capacitors supplied by Maxwell Energy Products, Inc., SAFT ...
Previous laboratory tests of elastomer O-rings in coal liquefaction solvents conducted at L'Garde, Inc., indicated that certain ethylenepropylenediene monomer (EPDM) compounds provided the best performance when a backup ring was used to limit swelling. Before service testing in a pump at the Wilsonville, Alabama, Advanced Coal Liquefaction Research and Development Facility, tests of six selected elastomers in the appropriate Wilsonville-produced solvent were conducted at Oak Ridge National Laboratory (ORNL). The ORNL tests measured the elastomers' changes in cross section, weight, density, and relative flexibility. Although two perfluoroelastomers showed less degradation of most properties during these tests, it was decided to proceed with service testing of two EPDM elastomers because of their much lower cost. 5 refs., 14 figs., 7 tabs.
This paper describes the test results on high-temperature strength properties of fire resistant steel(FR steel) for building, the formulation, and the examples of application to member tests and actual buildings. Because of its components and manufacturing method, FR steel excels in strength at elevated temperature due to precipitation and dispersion strengthening. Tests on high temperature properties of FR steel showed that every property such as strength, stress-strain curve, elastic modulus, and creep performance at high temperature was superior to those of conventional steels. Then, it was confirmed in the tensile tests at room temperature and high temperature after heat history that FR steel could be reused after fire. It was also found in the member tests that columns and beams of FR steel could support loadings equivalent to long-term allowable unit stress until the ...
An Allis-Chalmers, Model 2900, turbocharged diesel engine was converted to a dual-fuel engine in which ethyl alcohol was fumigated between the turbocharger and the intake manifold, and the diesel fuel was injected normally at a reduced rate. Tests were performed to determine if crankcase oil dilution that had occurred was caused by the following independent parameters: proof of the ethyl alcohol, crankcase oil temperature, engine load at maximum torque speed, and percentage of total energy in the form of ethyl alcohol. Engine tests were steady state for six hours, after which the crankcase oil was sampled for American Society for Testing and Materials (ASTM) laboratory tests for determination of flash points and fire points, water by centrifuge, water by distillation, and viscosity at room temperature. Results indicate a decrease in thermal efficiency and an increase in exhaust carbon monoxide as the ...
There is a plethora of new silver-containing dressings on the market today. Various manufacturers attempt to show that their dressings are the most efficacious and therefore should be preferentially employed by health care workers based on the results of their in vitro tests. However, there have been no studies that clearly identify which tests are appropriate for comparison purposes. The purpose of this study was to determine which in vitro test is most appropriate for evaluating the antimicrobial efficacy of silver-containing dressings. This was done by testing seven silver-containing dressings and two non-silver-containing topical agents against 17 clinically relevant microorganisms using zone of inhibition assays and time-kill kinetic assays in complex media. The results for the two assays were then correlated to determine whether the methods generated similar results. It was determined that the two ...
In situ toxicity tests were designed for Ceriodaphnia dubia and Chironomus tentans as part of a larger study designed to assess the effectiveness of constructed wetlands for the treatment of wastewater produced by oil production at Suncor OSG. The artificial wetlands were 50m long by 3m wide, with three replicates of the control and the treatment. Each wetland had four sample sites equidistant along its length, creating a gradient of treatment from site A being the most toxic to site D being the least toxic. Each test was conducted twice during the summer of 1994. Both the Ceriodaphnia and Chironomus test cages were a flow through design to allow for maximal exposure to the water within the wetlands. Mortality and reproduction were used as endpoints for Ceriodaphnia, whereas mortality and growth were used as endpoints for the Chironomus test. Test durations were fifteen and ten days ...
A 8.4 t/d pilot plant was completed in November 1994. Experimental operation for continuous tests have been carried out since December 1994. Two kinds of Indonesian sub-bituminous coals and an Australian lignite were upgraded and slurrified by the end of 1995. Typical pilot test results, such as coal concentration of upgraded sub-bituminous CWM of 65% and 4,700 kcal/kg heating value, were better than the authors expected. And subsequent combustion test in a 200 kg/h furnace was also successfully completed, with results showing very good combustibilities. This R and D is now in its final year, and the authors are conducting combustion tests on a big burner and gasification test, which will be carried out until March 1996. The test results from the pilot plant so far confirm the validity and economic feasibility of the upgrading and CWM production technology to ...
The present work's objective is to test sampling methodologies applied on the bioremediation processes in situ, involving the establishment of sample replicates, specific laboratory procedures and its results, inedited on the referred technique. Agricultural fertilizers were used, NPK and OSMOCOTE, as biostimulants on mangroves substrates affected by petroleum activities. The tested methodology used on the experiment was based on the monitoring of this technology in aquarium with water from Sao Paulo's river and sediment contaminated by oil, realized in three steps (first pre-test, second pre-test and third pre-test) that happened between the months of August and November of 2007. The physical-chemical parameters were measured with portable devices carefully calibrated and the oil analyzed with gas chromatography. The saturated hydrocarbons (n-alkenes) had an ...
This report presents the results of analysis of selected data from the NRU test series dealing with heatup and reflood heat transfer during postulated PWR LOCA conditions. These tests used nuclear fuel rods and some considered clad ballooning and rupture. Also included was an electrically-heated rod ballooning test, REBEKA-6. The COBRA-TF computer program, renamed PYTHONS, was modified and used for the analytical tool. Modifications included provisions for fuel rod gas flow and pressure, creep deformation and rupture, channel blockage, and blockage heat transfer. Calculated clad temperatures for NRU unpressurized rods show quite good agreement with experimental data. The calculated amount and axial extent of clad ballooning for pressurized rods agrees reasonably well with post-test examinations of the NRU bundles. Time to failure was underpredicted in the MT-3 test as a result of ...
The Magnet Test Facility at Fermilab tests a variety of full-scale and model superconducting magnets for both R and D and production. As the design characteristics and test requirements of these magnets vary widely, the magnet test stand must accommodate a wide range of Data Acquisition (DAQ) and Control requirements. Such a system must provide several functions, which includes: quench detection, quench protection, power supply control, quench characterization, and slow DAQ of temperature, mechanical strain gauge, liquid helium level, etc. The system must also provide cryogenic valve control, process instrumentation monitoring, and process interlock logic associated with the test stand. A DAQ and Control system architecture that provides the functionality described above has been designed, fabricated, and put into operation. This system utilizes a modular approach that provides both ...
Volume VII of the documentation for the Phase I Data Analysis Task performed in support of the current Regional Flow Model, Transport Model, and Risk Assessment for the Nevada Test Site Underground Test Area Subproject contains the tritium transport model documentation. Because of the size and complexity of the model area, a considerable quantity of data was collected and analyzed in support of the modeling efforts. The data analysis task was consequently broken into eight subtasks, and descriptions of each subtask's activities are contained in one of the eight volumes that comprise the Phase I Data Analysis Documentation.
Volume VI of the documentation for the Phase I Data Analysis Task performed in support of the current Regional Flow Model, Transport Model, and Risk Assessment for the Nevada Test Site Underground Test Area Subproject contains the groundwater flow model data. Because of the size and complexity of the model area, a considerable quantity of data was collected and analyzed in support of the modeling efforts. The data analysis task was consequently broken into eight subtasks, and descriptions of each subtask's activities are contained in one of the eight volumes that comprise the Phase I Data Analysis Documentation.
Volume IV of the documentation for the Phase I Data Analysis Task performed in support of the current Regional Flow Model, Transport Model, and Risk Assessment for the Nevada Test Site Underground Test Area Subproject contains the hydrologic parameter data. Because of the size and complexity of the model area, a considerable quantity of data was collected and analyzed in support of the modeling efforts. The data analysis task was consequently broken into eight subtasks, and descriptions of each subtask's activities are contained in one of the eight volumes that comprise the Phase I Data Analysis Documentation.
Volume II of the documentation for the Phase I Data Analysis Task performed in support of the current Regional Flow Model, Transport Model, and Risk Assessment for the Nevada Test Site Underground Test Area Subproject contains the potentiometric data. Because of the size and complexity of the model area, a considerable quantity of data was collected and analyzed in support of the modeling efforts. The data analysis task was consequently broken into eight subtasks, and descriptions of each subtask's activities are contained in one of the eight volumes that comprise the Phase I Data Analysis Documentation.
The author describes the history of the Soviet Unions nuclear weapons testing in Siberia from the first bomb on 29th August 1949 until the test-ban treaty of 1963. The effects of the weapons testing on the local population is only now becoming widely known. Levels of cancers and cataracts are significantly higher than in uneffected populations, and there are also high levels of some lung, bone, skin and digestive conditions. Perhaps the most important information relates to cataracts, previously thought to be caused by single large bursts of radiation. Regulatory authorities worldwide will need to tighten the safety limits for eye radiation exposure to these findings. (U.K.).
The author describes the history of the Soviet Unions nuclear weapons testing in Siberia from the first bomb on 29th August 1949 until the test-ban treaty of 1963. The effects of the weapons testing on the local population is only now becoming widely known. Levels of cancers and cataracts are significantly higher than in uneffected populations, and there are also high levels of some lung, bone, skin and digestive conditions. Perhaps the most important information relates to cataracts, previously thought to be caused by single large bursts of radiation. Regulatory authorities worldwide will need to tighten the safety limits for eye radiation exposure to these findings. (U.K.).
Field Programmable Gate Arrays (FPGAs) are being used in space applications because of attractive attributes: good density, moderate speed, low cost, and quick turn-around time. However, these devices are susceptible to Single Event Upsets (SEUs). An approach using triple modular redundancy (TMR) and feedback was developed for flip-flop hardening in these devices. Test data showed excellent results for this circuit topology. Total dose and Single Event Effect (SEE) testing have been performed on recently released technologies. Failures are analyzed and test methodology is discussed.
Several short model SSC 50 mm bore dipoles are being built and tested at Fermilab. Mechanical design of these magnets has been determined from experience involved in the construction and testing of 40 mm dipoles. Construction experience includes coil winding, curing and measuring, coil end part design and fabrication, ground insulation, instrumentation, collaring and yoke assembly. Fabrication techniques are explained and construction problems are discussed. Similarities and differences from the 40 mm dipole tooling and management components are outlined. Test results from the first models are presented. 19 refs., 12 figs.
This document presents an assessment of the severe accident phenomena observed from four Full-Length High-Temperature (FLHT) tests that were performed by the Pacific Northwest Laboratory (PNL) in the National Research Universal (NRU) reactor at Chalk River, Ontario, Canada. These tests were conducted for the US Nuclear Regulatory Commission (NRC) as part of the Severe Accident Research Program. The objectives of the test were to simulate conditions and provide information on the behavior of full-length fuel rods during hypothetical, small-break, loss-of-coolant severe accidents, in commercial light water reactors.
In this first quarterly technical report for DOE Contract No. DE-AC22-87PC79654, a description of the background, technology, and application is provided. The design and fabrication of advanced combustion chambers were completed during this period. Initial testing on both the bare metal and refractory lined advanced chambers were initiated. The units were tested initially with gas but primarily with coal. A Pittsburgh No. 8 pulverized coal was used for these test activities. Both advanced chambers pulsed well.
Characterization and performance testing of a prototype DWPF Melter No.2 Dome Heater Bus Bar are described. The prototype bus bar was designed to address the design features of the existing system which may have contributed to water leaks on Melter No.1. Performance testing of the prototype revealed significant improvement over the existing design in reduction of both bus bar and heater connection maximum temperature, while characterization revealed a few minor design and manufacturing flaws in the bar. The prototype is recommended as an improvement over the existing design. Recommendations are also made in the area of quality control to ensure that critical design requirements are met.