WorldWideScience
2

The S407, S409, and S410 Airfoils  

Science.gov (United States)

... 14(a)), a short laminar separation bubble is evident on the ... Natural Laminar Flow and Laminar Flow Control, RW Barnwell and MY ... AGARD CP No. ...

2010-08-01

3

Fundamental aspects of gas-liquid flows  

Energy Technology Data Exchange (ETDEWEB)

This book presents the papers given at a conference on two-phase flow. Topics considered at the conference included the thermal hydraulics of a feedwater pipe breakage, pressure losses, measurement of void fraction in a rod bundle, laminar filmwise condensation, natural circulation, flow models, bubble dynamics, cavitation, water hammer, and heat transfer augmentation.

1985-01-01

4

Fundamental aspects of gas-liquid flows  

International Nuclear Information System (INIS)

This book presents the papers given at a conference on two-phase flow. Topics considered at the conference included the thermal hydraulics of a feedwater pipe breakage, pressure losses, measurement of void fraction in a rod bundle, laminar filmwise condensation, natural circulation, flow models, bubble dynamics, cavitation, water hammer, and heat transfer augmentation.

1985-11-17

5

Flow visualization II Proceedings of the Second International Symposium, Bochum, West Germany, September 9-12, 1980  

Energy Technology Data Exchange (ETDEWEB)

Applications, techniques, instrumentation, and interpretation of flow visualization are discussed. Methods of using flow visualization for the examination of combustion in furnaces, heat transfer with heat exchangers, and in fluid engines are explored, along with flow visualization in food processing, steel-casting, and process engineering. Further attention is given to pipe and channel flow, flow separation in laminar flow and around oscillating airfoils, wakes and vortices, supersonic flow and shock waves, and stratified flow and oceanography. The visualization of boundary layers is considered for various conditions, and applications for multiphase flow, rheology, and medical problems are detailed. Oil film, dry-surface coating, chemical, fluorescent, and ...

1982-01-01

6

LAMINAR SEPARATION IN SUPERSONIC AND ...  

Science.gov (United States)

... Agard Report 272,1960 ... and reattached subsonic turbulent flows obtained downstream ... of flow separations due to deflected control surfaces. ...

1966-09-30

7

Free and forced convective cooling of pipe-type electric cables. Volume 2: electrohycrodynamic pumping. Final report  

Energy Technology Data Exchange (ETDEWEB)

A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one, reported in Volume 1, dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of ...

1981-05-01

8

Free and forced convective cooling of pipe-type electric cables. Volume 1: forced cooling of cables. Final report  

Energy Technology Data Exchange (ETDEWEB)

A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one reported in this volume dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of ...

1981-05-01

9

Augmentation of laminar flow and heat transfer in flat tubes by means of helical screw-tape inserts  

British Library Electronic Table of Contents (United Kingdom)

The heat transfer a characteristics and friction factor in the horizontal double pipes of flat tubes with full length helical screw element of different twist ratio and helical screw inserts with different spacer length are investigated. Cold and hot water are used as working fluid in tube side and shell side respectively. The experiments covered a range of Reynolds numbers 5.7x102Re1.31x103. The effect of spacer length on the heat transfer augmentation and friction factor and the effect of twist ratio on heat transfer augmentation and friction factor have been presented separately. The study shows that, the Nusslet number (Nu) and friction factor (f) decrease with the increase of S or Y for flat tube. The comparison between the data of present plain circular with that of previous plain ci...

2011-01-01

10

Mixed convection flows in a channel with a vortex generator  

Science.gov (United States)

This paper presents a numerical investigation of laminar flows and heat transfer in a horizontal rectangular channel whose top and bottom plates have been punched out in the form of a delta wing. The flow structure with respect to the generation, transport, and stability of vortices in laminar horizontal channel flows with combined forced and free convection are reported. To include free convection, Boussinesq approximation of the buoyancy is used and the flow medium is treated as incompressible.

1989-01-01

11

Augmentation of laminar flow and heat transfer in flat tubes by means of helical screw-tape inserts  

Energy Technology Data Exchange (ETDEWEB)

The heat transfer a characteristics and friction factor in the horizontal double pipes of flat tubes with full length helical screw element of different twist ratio and helical screw inserts with different spacer length are investigated. Cold and hot water are used as working fluid in tube side and shell side respectively. The experiments covered a range of Reynolds numbers 5.7 x 10{sup 2} {<=} Re {<=} 1.31 x 10{sup 3}. The effect of spacer length on the heat transfer augmentation and friction factor and the effect of twist ratio on heat transfer augmentation and friction factor have been presented separately. The study shows that, the Nusslet number (Nu) and friction factor (f) decrease with the increase of S or Y for flat tube. The comparison between the data of present plain circular with that of previous plain circular tube showed a good agreement between them but the data of present plain flat tube showed a higher in heat transfer and pressure ...

2011-01-15

12

Analysis of laminar flow heat transfer in uniform temperature circular tubes with tape inserts  

Science.gov (United States)

Constant property, laminar flow heat transfer in a semicircular tube with uniform wall temperature has been analyzed to define the lower bound of heat transfer augmentation in circular tubes with twisted-tape inserts. Two thermal boundary conditions, which correspond to the two extremes of the fin effect of twisted tapes encountered in practical applications, are considered. Numerical solutions, employing finite-difference formulations for the governing momentum and energy equations were carried out for the thermal entrance region and for fully developed flow.

1986-05-01

13

Heat transfer characteristics of laminar flow in internally finned tubes under various boundary conditions  

Science.gov (United States)

Numerical solutions for fully developed laminar flow in internally finned tubes with trapezoidal and triangular fin profiles were given with Finite Element Method (FEM): The heat transfer characteristics were obtained and compared under the boundary conditions of uniform heat flux, uniform wall temperature, and the third boundary condition with finite wall thermal conductivity considered. The numerical results show that boundary conditions have pronounced effects on the temperature field. Furthermore, a new mechanism on the heat transfer augmentation of internally finned tubes is proposed.

1994-06-01

14

Unsteady transonic flow computations for AGARD two dimensional and three dimensional aeroelastic configurations  

Science.gov (United States)

Numerical results on aeroelastic standard configurations are presented. The methods used for two dimensional configurations include the small perturbations approach for inviscid flow, coupling methods for unseparated flow, coupling methods for unseparated or separated, laminar or turbulent boundary layers, and a numerical solution of the Euler equations for inviscid flow. The three dimensional configurations are studied by the transonic small disturbance approach. The detailed results are given.

1986-12-01

15

Convective heat transfer in annular flow  

International Nuclear Information System (INIS)

Several aspects of heat transfer at the annular two phase flow regime are considered. Nucleate boiling is supposed to be absent. Theoretical solutions for cases of laminar and turbulent flow in the liquid film, respectively, are considered, when steam presence does not effect the heat transfer. Heat transfer in annular flows is also considered, where steam phase consists totally or partially of the so-called incondensable gas. In this case steam phase can be a considerable resistance to heat transfer.

1980-01-01

16

Flooding characteristics of gas-liquid two-phase flow in a horizontal U bend pipe  

International Nuclear Information System (INIS)

To evaluate safety of horizontal steam generator used in passive safety system, it is needed to make clear flooding characteristics in U bend pipe. In this study, two-phase flow experiment in a horizontal U bend pipe was carried out to make clear the influence of the length of horizontal pipe and the radius of U bend. Flooding in the U bend pipe was observed in the condition of lower gas or liquid volumetric flux than that in the horizontal pipe or the vertical pipe. Flooding and carry-up in the U bend pipe is hardly change with increasing the length between the water inlet and the U bend, but greatly related with the length from the water inlet to the lower tank and the shape of the U bend inlet. (author).

1994-05-01

17

Three-dimensional laminar and turbulent natural convection cooling of heated blocks  

International Nuclear Information System (INIS)

Results of three-dimensional laminar and standard K-#epsilon# turbulent numerical simulations of natural convection cooling of ten cubic aluminum blocks mounted on an insulated plate, facing a shrouding wall, are presented. This geometry is chosen so that comparison with experimental results is possible. The considered problem is of great practical importance because it simulates the case of heated electronic chips, mounted on printed board assemblies, which are frequently encountered in electronic industry applications. The problem is mathematically modeled by the three-dimensional conservation differential equations of mass, momentum, energy and turbulent kinetic energy and dissipation (for the turbulent flow model). IN this paper, these equations are numerically solved by a finite volume method and the laminar and turbulent results are compared to the experimental results obtained with similar parameters.

1990-06-18

18

Determination of critical length for pipe whip design  

Energy Technology Data Exchange (ETDEWEB)

Design of pipe whip restraints requires a knowledge of the maximum allowable unsupported pipe length. This paper presents a numerical method for calculating this critical length of the pipe. Salient features of the method are: (1) as a flow rounds an elbow, it exerts a transverse kick and an axial thrust to the pipe, both the axial thrust and the bending moment are considered; (2) the jet force is applied in an abrupt manner, the dynamic amplification factor (DAF) is determined from the load-deflection (H-{Delta}) curve of the pipe, by taking into consideration large strain, large deformation and the nonlinear stress-strain relationship of the piping material; (3) the ultimate capacity of the pipe under the combined action of an axial force and a bending moment is governed by an interaction formula. The maximum ...

1995-11-01

19

Flow field and heat transfer associated with laminar flow over a forward-facing step  

Science.gov (United States)

The flow and heat transfers associated with a plane laminar flow past a forward-facing step were analyzed using a power-law numerical scheme combined with a false vorticity-stream function approach. To improve the traditional wall-vorticity boundary condition, a novel method, based on an accurate description of the nonslip wall condition, was developed and utilized. The convergence for a 56 x 49 grid system was obtained in about 350 iterations. The computed reattachment distances in the upper separated region agree with the available experimental data for a blunt plate. The heat transfer augmentation is significant across the step; however, it is counterbalanced by the deterioration of heat transfer immediately upstream of the step.

1986-01-01

20

Pipe whip studies  

Energy Technology Data Exchange (ETDEWEB)

An experimental and analytical study was performed to improve understanding of the dynamic impact behavior of carbon steel pipes. The test program addressed two types of pipe impact scenarios using both 2- and 4-in. Sch-80 pipes and elbows. Projectile-on-pipe tests simulated the behavior of a stationary target pipe which is impacted at its center by a larger, more rigid whipping pipe. These target pipes, which contained non-flowing water at about 290{degree}C temperature and ca 8.5 megapascals pressure, exhibited a peak deformation of up to 45% reduction in their diameter. For each test condition, the local deformation at the impact zone is a function of the peak impact force and impact velocity. Pipe-on-wall tests simulated the impact of an elbow at the free end of a cantilevered whipping ...

1984-06-01

21

Development of electro-optical instrumentation for annular two-phase flow studies  

International Nuclear Information System (INIS)

The development of new electro-optical instrumentation for studying the annular dispersed two-phase flow regime is described. The system measures the thickness of the water film and droplet size and velocity distributions which would be encountered in such a flow regime. The water film thickness is measured by an improved capacitance method with a short time constant using newly developed sensor electrodes. The electrodes are made flush with the inner wall of a cylindrical tube and do not disturb the flow. In the test equipment, steady, laminar flow of water along the inner wall of the tube is controlled by appropriate valves and a porous jacket while droplets are introduced by means of a special spray nozzle.

1981-01-01

22

Review of passive heat transfer augmentation techniques  

Energy Technology Data Exchange (ETDEWEB)

Heat transfer augmentation techniques (passive, active or a combination of passive and active methods) are commonly used in areas such as process industries, heating and cooling in evaporators, thermal power plants, air- conditioning equipment, refrigerators, radiators for space vehicles, automobiles, etc. Passive techniques, where inserts are used in the flow passage to augment the heat transfer rate, are advantageous compared with active techniques, because the insert manufacturing process is simple and these techniques can be easily employed in an existing heat exchanger. In design of compact heat exchangers, passive techniques of heat transfer augmentation can play an important role if a proper passive insert configuration can be selected according to the heat exchanger working condition (both flow and heat transfer conditions). In the past decade, several studies on the passive techniques of heat transfer augmentation have been reported. ...

2004-12-01

23

Performance of a commercial heat pipe under operational conditions  

Energy Technology Data Exchange (ETDEWEB)

The performance of a commercial heat pipe was investigated both experimentally and theoretically. The effect of the temperature difference, the surface area ratio, and the operational conditions on the performance were studied. The heat flow rate and the vapor temperature were estimated on a ready-made commercial heat pipe. Its performance varied considerably with operational conditions. Theoretical consideration of a mathematical model and several nomographs are also presented. This work is applicable to the design and use of heat pipes in the field.

1983-04-01

24

Analysis of laminar flow and heat transfer in the entrance region of an internally finned concentric circular annular duct  

Energy Technology Data Exchange (ETDEWEB)

The concentric circular annular duct is a common geometry in many fluid flow and heat transfer devices. For the purpose of heat transfer augmentation, fins are often employed in the annular region, and such finned ducts find wide application in compact heat exchangers (5, 6). The analysis of flow and heat transfer in this geometry is, therefore, quite important from an engineering standpoint. For fully developed conditions, the problem has already been analyzed (7-10). However, no results are available for the developing flow in the entrance region. It is with this latter problem that the present paper is concerned.

1987-05-01

25

Visualization of disturbed flow with spin-echo and cine MR imaging  

International Nuclear Information System (INIS)

MR images of steady and pulsatile disturbed flow, obtained with use of flow-compensated spin-echo (SE) and cine pulse sequences, revealed excellent flow visualization in three dimensions. Phantoms, built from molds of actual blood vessels, reproduced laminar, disturbed, or turbulent flow. Video recording (VR), performed under conditions equivalent to those of the MR experiments, showed separation zones identical to those seen on SE images. Pulsatile flow studies showed complex patterns of vortical flow on cine images and VR. Varying pulse sequence details changed contrast but not flow patterns. The validation of MR observations by VR has implications for clinical cine imaging and low abnormal signals observed on MR angiograms.

26

Two-phase flow regime transition in large diameter vertical pipes  

Energy Technology Data Exchange (ETDEWEB)

The two-phase flow regime transition in a large diameter (I.D.=200mm) vertical pipe was experimentally investigated using a dual-sensor optical probe. The flow transitions from bubbly to chum without an intermediate slug flow regime as the air flow rate is increased. The transition boundaries developed for bubbly to slug flow in small diameter pipes are compared to the bubbly to chum flow transition of the present experiment. The bubbly to chum transition occurs at a void fraction of about 0.15 compared to 0.25 for bubbly to slug transition in small diameter pipes. The radial distribution of bubble diameter, bubble frequency, bubble velocity and local void fraction were obtained using a dual-sensor optical probe at different flow conditions. The Probability Density Function (PDF) ...

2002-07-01

27

Two-phase flow regime transition in large diameter vertical pipes  

International Nuclear Information System (INIS)

The two-phase flow regime transition in a large diameter (I.D.=200mm) vertical pipe was experimentally investigated using a dual-sensor optical probe. The flow transitions from bubbly to chum without an intermediate slug flow regime as the air flow rate is increased. The transition boundaries developed for bubbly to slug flow in small diameter pipes are compared to the bubbly to chum flow transition of the present experiment. The bubbly to chum transition occurs at a void fraction of about 0.15 compared to 0.25 for bubbly to slug transition in small diameter pipes. The radial distribution of bubble diameter, bubble frequency, bubble velocity and local void fraction were obtained using a dual-sensor optical probe at different flow conditions. The Probability Density Function (PDF) ...

2002-06-02

28

A relativistic mixing-layer model for jets in low-luminosity radio galaxies  

CERN Document Server

We present an analytical model for jets in Fanaroff & Riley Class I (FRI) radio galaxies, in which an initially laminar, relativistic flow is surrounded by a shear layer. We apply the appropriate conservation laws to constrain the jet parameters, starting the model where the radio emission is observed to brighten abruptly. We assume that the laminar flow fills the jet there and that pressure balance with the surroundings is maintained from that point outwards. Entrainment continuously injects new material into the jet and forms a shear layer, which contains material from both the environment and the laminar core. The shear layer expands rapidly with distance until finally the core disappears, and all of the material is mixed into the shear layer. Beyond this point, the shear layer expands in a cone and decelerates smoothly. We apply our model to the well-observed FRI source 3C31 ...

2009-01-01

29

Pressure drop and heat transfer characteristics of boiling water in sub-hundred micron channel  

Energy Technology Data Exchange (ETDEWEB)

The current work focuses on the pressure drop, heat transfer and stability in two phase flow in microchannels with hydraulic diameter of less than one hundred microns. Experiments were conducted in smooth microchannels of hydraulic diameter of 45, 65 {mu}m, and a rough microchannel of hydraulic diameter of 70 {mu}m, with deionised water as the working fluid. The local saturation pressure and temperature vary substantially over the length of the channel. In order to correctly predict the local saturation temperature and subsequently the heat transfer characteristics, numerical techniques have been used in conjunction with the conventional two phase pressure drop models. The Lockhart-Martinelli (liquid-laminar, vapour-laminar) model is found to predict the two phase pressure drop data within 20%. The instability in two phase flow is quantified; it is found that microchannels of smaller hydraulic diameter ...

2009-09-15

30

Advances in enhanced heat transfer: 1987  

Energy Technology Data Exchange (ETDEWEB)

This book contains nine selections. Some of the titles are: High Heat-Flux, Forced-Convection Heat Transfer for Tubes with Twisted-Tape Inserts; Heat Transfer Augmentation by Interrupted Surfaces - Experimental Consideration; Turbulent Flow Heat Transfer from Externally Roughened Tubes in Axial Flow in Concentric Pipe Heat Exchangers; and Heat Transfer Enhancement of Turbulent Flow in Pipes with an Internal Circular Rib.

1987-01-01

31

Advances in enhanced heat transfer: 1987  

International Nuclear Information System (INIS)

This book contains nine selections. Some of the titles are: High Heat-Flux, Forced-Convection Heat Transfer for Tubes with Twisted-Tape Inserts; Heat Transfer Augmentation by Interrupted Surfaces - Experimental Consideration; Turbulent Flow Heat Transfer from Externally Roughened Tubes in Axial Flow in Concentric Pipe Heat Exchangers; and Heat Transfer Enhancement of Turbulent Flow in Pipes with an Internal Circular Rib.

1987-08-09

32

Aerodynamic design of a midsized vertical-axis wind turbine using natural laminar-flow blade elements  

Science.gov (United States)

Natural laminar-flow (NLF) airfoils are those which can achieve significant extents of laminar flow (greater than or equal to 30% chord) solely through favorable pressure gradients. Studies have shown that vertical-axis wind turbines (VAWTs) using NLF sections as blade elements have the potential of producing energy at a significantly lower cost (approx. =20%) than turbines of current design. Sandia National Laboratories (SNL) is now in the process of procuring a blade set for its 17-m-diameter research turbine which will use NLF sections as blade elements. This paper describes the design of this blade set. The blade set design began with the definition of a family of three approximately 50% chord NLF sections (15, 18, and 21% t/c). These definitions involved numerically establishing airfoil contours giving section characteristics anticipated to be favorable in the VAWT context and then screening these using a VAWT ...

1983-01-01

33

Study on the evaluation of vibration effect and the development of vibration reduction method for Wolsung unit 1 main steam piping.  

Science.gov (United States)

The main steam piping of nuclear power plant which runs between steam generator and high pressure turbine has been experienced to have a severe effect on the safe operation of the plant due to the vibration induced by the steam flowing inside the piping. ...

1996-01-01

34

Approximate method for the determination of the response frequency of pipe whip. [With fluid flowing in the pipe at different velocities  

Energy Technology Data Exchange (ETDEWEB)

An approximate analysis based on the virtual work technique, which was used to determine the effect of fluid velocity on the response frequency of a simply supported pipe, resulted in the following conclusions: (1) the critical fluid velocity at which the system becomes statically unstable is 129.5 ft/s; (2) the natural frequency of the pipe decreases as the fluid velocity increases; (3) higher flow rates increase the dynamic coupling of the system, making it much more susceptible to external excitation; (4) as the critical frequency approaches zero and the fluid velocity approaches the critical value, the amplitude becomes greater (though in an actual pipe, damping effects will limit the amplitude somewhat); and (5) the virtual work technique is a convenient method for approximating solutions to most non-linear vibration problems, giving results that are satisfactory for engineering-design purposes.

1980-05-01

35

Mass transfer in horizontal flow channels with thermal gradients  

Energy Technology Data Exchange (ETDEWEB)

Mass transfer to a wall of a horizontal rectangular channel reactor was investigated by the limiting current technique for Reynolds numbers ranging from 200 to 32000. Overall mass transfer coefficients at various mass transfer surface angles were obtained while the reactor was operated under isothermal and non-isothermal conditions. Dimensionless correlations were developed for isothermal flows from 25 to 55{sup o}C and for non-isothermal flows with applied temperature differences up to 30{sup o}C. In the laminar flow range natural convection dominated, but under turbulent conditions combined natural and forced convection prevailed. Mass transfer was approximately doubled under optimum selection of channel surface rotation, temperature gradient and flow rate. (author)

1997-12-15

36

Mass transfer in horizontal flow channels with thermal gradients  

International Nuclear Information System (INIS)

Mass transfer to a wall of a horizontal rectangular channel reactor was investigated by the limiting current technique for Reynolds numbers ranging from 200 to 32000. Overall mass transfer coefficients at various mass transfer surface angles were obtained while the reactor was operated under isothermal and non-isothermal conditions. Dimensionless correlations were developed for isothermal flows from 25 to 55"oC and for non-isothermal flows with applied temperature differences up to 30"oC. In the laminar flow range natural convection dominated, but under turbulent conditions combined natural and forced convection prevailed. Mass transfer was approximately doubled under optimum selection of channel surface rotation, temperature gradient and flow rate. (author)

1997-12-01

37

Development of electro-optical instrumentation for annular two-phase flow studies. [PWR  

Energy Technology Data Exchange (ETDEWEB)

The development of new electro-optical instrumentation for studying the annular dispersed two-phase flow regime is described. The system measures the thickness of the water film and droplet size and velocity distributions which would be encountered in such a flow regime. The water film thickness is measured by an improved capacitance method with a short time constant using newly developed sensor electrodes. The electrodes are made flush with the inner wall of a cylindrical tube and do not disturb the flow. In the test equipment, steady, laminar flow of water along the inner wall of the tube is controlled by appropriate valves and a porous jacket while droplets are introduced by means of a special spray nozzle.

1981-05-01

38

Thermally developing flow in curved square ducts with internal fins  

Energy Technology Data Exchange (ETDEWEB)

The laminar incompressible hydrodynamically fully developed and thermally developing flow is studied in a curved square duct with four longitudinal fins. The duct is successively subjected to constant wall temperature, to circumferentially uniform temperature and axially linearly or exponentially varying temperature. The local and fully developed Nusselt numbers are examined for various values of the Dean number and it is found that the heat transfer rate increases for high fins. The parameters that affect the entry length are studied and the fluctuations of the local Nu that appear in the entrance region are investigated. Temperature contour plots are presented for the visualization of the temperature field and functional relations for the Nusselt number are proposed in terms of the Dean and Prandtl numbers. (orig.)

2005-11-01

39

Hydrothermal coupling in a rough fracture  

CERN Document Server

Heat exchange during laminar flow is studied at the fracture scale on the basis of the Stokes equation. We used a synthetic aperture model (a self-affine model) that has been shown to be a realistic geometrical description of the fracture morphology. We developed a numerical modelling using a finite difference scheme of the hydrodynamic flow and its coupling with an advection/conduction description of the fluid heat. As a first step, temperature within the surrounding rock is supposed to be constant. Influence of the fracture roughness on the heat flux through the wall, is estimated and a thermalization length is shown to emerge. Implications for the Soultz-sous-For\\^{e}ts geothermal project are discussed.

2006-01-01

40

Effects of thermophoresis and radiation on laminar flow along a semi-infinite vertical plate  

British Library Electronic Table of Contents (United Kingdom)

The present contribution deals with the thermophoresis particle deposition and thermal radiation effects on the flow, heat and mass transfer characteristics in a viscous fluid over a semi-infinite vertical porous plate. The governing boundary layer equations are written into a dimensionless form by similarity transformations. The transformed coupled nonlinear ordinary differential equations are solved numerically by means of the fourth-order Runge?Kutta method with a shooting technique. The effects of different parameters on the dimensionless velocity, temperature, and concentration profiles are shown graphically. In addition, results for the local skin-friction coefficient, the local Nusselt number, and the local Sherwood number are tabulated and discussed.

2011-01-01

41

Effects of thermophoresis and radiation on laminar flow along a semi-infinite vertical plate  

Science.gov (United States)

The present contribution deals with the thermophoresis particle deposition and thermal radiation effects on the flow, heat and mass transfer characteristics in a viscous fluid over a semi-infinite vertical porous plate. The governing boundary layer equations are written into a dimensionless form by similarity transformations. The transformed coupled nonlinear ordinary differential equations are solved numerically by means of the fourth-order Runge-Kutta method with a shooting technique. The effects of different parameters on the dimensionless velocity, temperature, and concentration profiles are shown graphically. In addition, results for the local skin-friction coefficient, the local Nusselt number, and the local Sherwood number are tabulated and discussed.

2011-04-01

42

Microgravity two-phase flow regime modeling  

Energy Technology Data Exchange (ETDEWEB)

A flow pattern or flow regime is the characteristics spatial distribution of the phases of fluid in a duct. Since heat transfer and pressure drop are dependent on the characteristic distribution of the phases, it is necessary to describe flow patterns in an appropriate manner so that a hydrodynamic or heat transfer theory applicable to that pattern can be chosen. The objective of the present analysis is to create a flow regime map based on physical modeling of vapor/liquid interaction phenomena in a microgravity environment. In the present work, four basic flow patterns are defined: dispersed flow, stratified flow, slug flow, and annular flow. Fluid properties, liquid and vapor flow rates, and pipe size were chosen as the principal parameters. It is assumed ...

1987-01-01

43

Kinetics of absorption of trace iodine vapor in aqueous solution of sodium hydroxide, (2)  

International Nuclear Information System (INIS)

A liquid column was used for the experiments reported in Part 1. However, it only gives the observation of the effect of fast reaction because the liquid flow was controlled to uniform laminar flow and the contact is limited to short time of around 10 ms. In practical absorbing operation, turbulence is involved in liquid flow, and the residence time for contact is long. Hence, the absorption of trace iodine in the purified air has been experimented by using a constant interface area type stirred absorption tank. Prior to the experiment, the characteristics of the absorption tank was investigated by conducting pure carbon dioxide absorption test with purified water. It gave the conclusion that the tank was sufficiently usable for fundamental researches. In short contact time absorption, the iodine dissolved and absorbed in liquid phase is affected by reaction of hypoiodous acid and poly-iodide ion ...

1978-01-01

44

Forced laminar convection in an array of stacked plates  

Energy Technology Data Exchange (ETDEWEB)

A numerical study of laminar flow and heat transfer in an array of stacked rectangular plates is presented. The array is placed in a uniform stream, and the plates are subjected to a constant surface heat flux. This flow configuration is relevant to a number of practical heat transfer devices with finned surfaces. The computations were performed using a finite volume solution of the steady, two-dimensional Navier-Stokes equations and energy equation. A numerical scheme that reduces numerical diffusion is used to discretize the equations. The dominant feature of the flow is the separation, and subsequent reattachment of, the boundary layer, which takes place at Reynolds numbers greater than about 75. The separation first occurs downstream of the leading edge of the plate; then as Re increases, the separation point moves upstream and remains fixed at the leading edge, and the reattachment length increases ...

1994-04-01

45

CFD Application to the Regulatory Assessment of FAC-Caused CANDU Feeder Pipe Wall Thinning Issue  

Energy Technology Data Exchange (ETDEWEB)

From the results of the In-Service Inspection (ISI) measuring the wall thickness of outlet (hot-leg side) feeder pipes performed at two Canadian nuclear power plants, Point Lepreau and Gentilly-2 in 1995 and 1996, respectively, the wall thinning degradation of feeder pipes at the bend part was found to be much more severe than expected. It has been well known that such wall thinning of feeder pipes is caused by the flow accelerated corrosion (FAC) which is one of the mechanical-chemical degradation mechanisms affecting the integrity of piping systems. For the Wolsung unit 1, the wall thickness measurements have been performed during every overhaul period since 1996. The wall thinning rates at the bends of outlet feeder pipes were assessed to exceed the design value. However, for the Wolsung units 2, 3 and 4, the wall thinning rates of all the outlet feeder ...

2007-07-01

46

CFD Application to the Regulatory Assessment of FAC-Caused CANDU Feeder Pipe Wall Thinning Issue  

International Nuclear Information System (INIS)

From the results of the In-Service Inspection (ISI) measuring the wall thickness of outlet (hot-leg side) feeder pipes performed at two Canadian nuclear power plants, Point Lepreau and Gentilly-2 in 1995 and 1996, respectively, the wall thinning degradation of feeder pipes at the bend part was found to be much more severe than expected. It has been well known that such wall thinning of feeder pipes is caused by the flow accelerated corrosion (FAC) which is one of the mechanical-chemical degradation mechanisms affecting the integrity of piping systems. For the Wolsung unit 1, the wall thickness measurements have been performed during every overhaul period since 1996. The wall thinning rates at the bends of outlet feeder pipes were assessed to exceed the design value. However, for the Wolsung units 2, 3 and 4, the wall thinning rates of all the outlet feeder ...

2007-05-10

47

A note on the flow and heat transfer enhancement in a channel with built-in winglet pair  

International Nuclear Information System (INIS)

Counter rotating longitudinal vortices produced by winglet in a channel are known to enhance heat transfer. In the present investigation the flow structure and heat-transfer enhancement by a winglet pair of non-zero thickness has been studied. A delta winglet pair type vortex generator is placed in a hydrodynamically developed and thermally developing laminar channel flow. Computations are done by solving the unsteady, three-dimensional, incompressible Navier-Strokes equations and energy equation using a modified Marker-and-Cell (MAC) method. The flow structure is complex and consists of main, corner and induced vortices. It is observed that as compared to a channel without winglets, the heat transfer is enhanced by 33% when single winglet is used and by 67% when a winglet pair is employed. Effects of thickness of the winglets and Reynolds number on the heat transfer augmentation are presented.

2007-04-01

48

High thermal load receiving heat plate  

Energy Technology Data Exchange (ETDEWEB)

The present invention concerns a high thermal load heat receiving plate such as a divertor plate of a thermonuclear device. The high thermal load heat receiving plate of the present invention has a cooling performance capable of suppressing the temperature of an armour tile to less than a threshold value of the material against high thermal loads applied from plasmas. Spiral polygonal pipes are inserted in cooling pipes at a portion receiving high thermal loads in the high temperature load heat receiving plate of the present invention. Both ends of the polygonal pipes are sealed by lids. An area of the flow channel in the cooling pipes is thus reduced. Heat conductivity on the cooling surface of the cooling pipes is increased in the high thermal load heat receiving plate having such a structure. Accordingly, temperature elevation of the armour tile can be ...

1993-09-28

49

Flow Regime Map Models for the Horizontal and Vertical Pipes for the SPACE code  

Energy Technology Data Exchange (ETDEWEB)

A safety analysis code, named as SPACE, for a pressurized water reactor is under development to obtain a licensing to be used for the PWR design and to hold entire proprietary rights. The task of KAERI is to develop the physical models and correlations which are required to solve the field equations. It can be divided into four parts; i) flow regime determination, ii) wall heat transfer, iii) wall and interfacial friction, iv) interfacial heat and mass transfer. This paper will describe the process to develop the models for the two-phase flow regime maps in the horizontal and vertical pipes.

2008-05-15

50

Flow Regime Map Models for the Horizontal and Vertical Pipes for the SPACE code  

International Nuclear Information System (INIS)

A safety analysis code, named as SPACE, for a pressurized water reactor is under development to obtain a licensing to be used for the PWR design and to hold entire proprietary rights. The task of KAERI is to develop the physical models and correlations which are required to solve the field equations. It can be divided into four parts; i) flow regime determination, ii) wall heat transfer, iii) wall and interfacial friction, iv) interfacial heat and mass transfer. This paper will describe the process to develop the models for the two-phase flow regime maps in the horizontal and vertical pipes.

2008-05-01

51

Application of a 3-beam #gamma# densitometer to two-phase flow regime and density measurements  

International Nuclear Information System (INIS)

A method of using gamma radiation to determine the density and phase distribution in two-phase flows in pipes is described. Three collimated beams of radiation that pass through a pipe cross-section at different radial positions are used. A theory and computer program used to relate the measured attenuation of these beams to a three-parameter model of the phase distribution and to the average density and void fraction are discussed. Data obtained during both static and dynamic verification experiments using Lucite inserts are presented, as well as the results of several tests done in high pressure, steam-water flows.

1976-08-11

52

Dynamic response of a liquid-vapor interface during flow film boiling from a sphere  

Energy Technology Data Exchange (ETDEWEB)

Film boiling is the mode if boiling during which the hot surface is separated from the vaporizing liquid by a nearly continuous film vapor. Film boiling is usually considered a very undesirable boiling regime since it is a relatively quiet and inefficient mode of heat transfer, particularly as compared to nucleate boiling. It is customary to analyze the two-phase flow regime of laminar flow film boiling by assuming the two-phase flow regime of laminar flow film boiling by assuming an idealized vapor film flow characterized by a smooth liquid-vapor interface. However, during stable flow film boiling, the wavy nature of the liquid-vapor interface and its role in local heat and mass transport have been largely ignored. The vapor interface is rarely stationary. Interfacial waves may substantially augment the heat transfer ...

1987-11-01

53

Two-phase flow regime observations in a vertical hexagonal flow channel with and without a finned fuel bundle  

International Nuclear Information System (INIS)

Previous flow regime studies have been for horizontal, vertical, and inclined pipe flow. As such, only a few studies have been performed on bundle geometries. The present paper examines the flow regimes for a vertical hexagonal flow channel with and without a finned fuel bundle. This type of a 36 finned rod hexagonal fuel bundle in parallel hexagonal flow channels is used in a MAPLE (Multi- purpose Applied Physics Lattice Experimental) type nuclear reactor. An experiment apparatus was designed consisting of the flow channel, inlet plenum and an air-water separator. The inlet plenum is used to provide a uniform mixture of air and water before entering the hexagonal flow channel. A turbine flow meter is used to determine the water flow rate. The turbine flow ...

1990-12-10

54

Mechanisms of radical removal by SO2  

DEFF Research Database (Denmark)

It is well established from experiments in premixed, laminar flames, jet-stirred reactors, flow reactors, and batch reactors that SO2 acts to catalyze hydrogen atom removal at stoichiometric and reducing conditions. However, the commonly accepted mechanism for radical removal, SO2 + H(+M) reversible arrow HOSO(+M), HOSO + H/OH reversible arrow SO2 + H-2/H2O, has been challenged by recent theoretical and experimental results. Based on ab initio calculations for key reactions, we update the kinetic model for this chemistry and re-examine the mechanism of fuel/SO2 interactions. We find that the interaction of SO, with the radical pool is more complex than previously assumed, involving HOSO and SO, as well as, at high temperatures also HSO, SH, and S. The revised mechanism with a high rate constant for H + SO2 recombination and with SO + H2O, rather than SO2 + H-2, as major products of the HOSO + H reaction is in agreement with a range of ...

2007-01-01

55

Experimental studies on heat transfer and friction factor characteristics of laminar flow through a circular tube fitted with regularly spaced helical screw-tape inserts  

Energy Technology Data Exchange (ETDEWEB)

Experimental investigation of heat transfer and friction factor characteristics of circular tube fitted with full-length helical screw element of different twist ratio, and helical screw inserts with spacer length 100, 200, 300 and 400mm have been studied with uniform heat flux under laminar flow condition. The experimental data obtained are verified with those obtained from plain tube published data. The effect of spacer length on heat transfer augmentation and friction factor, and the effect of twist ratio on heat transfer augmentation and friction factor have been presented separately. The decrease in Nusselt number for the helical twist with spacer length is within 10% for each subsequent 100mm increase in spacer length. The decrease in friction factor is nearly two times lower than the full length helical twist at low Reynolds number, and four times lower than the full length helical twist at high Reynolds number for all twist ratio. The ...

2007-02-15

56

A two-phase flow regime map for a MAPLE-type nuclear research reactor fuel channel: Effect of hexagonal finned bundle  

Energy Technology Data Exchange (ETDEWEB)

A two-phase flow regime map is developed experimentally and theoretically for a vertical hexagonal flow channel with and without a 36-finned rod hexagonal bundle. This type of flow channel is of interest to MAPLE-type nuclear research reactors. The flow regime maps are determined by visual observations and observation of waveforms shown by a capacitance-type void fraction meter. The experimental results show that the inclusion of the finned hexagonal bundle shifts the flow regime transition boundaries toward higher water flow rates. Existing flow regime maps based on pipe flow require slight modifications when applied to the hexagonal flow channel with and without a MAPLE-type finned hexagonal bundle. The proposed theoretical model agrees well with experimental results.

1997-05-01

57

A two-phase flow regime map for a MAPLE-type nuclear research reactor fuel channel: Effect of hexagonal finned bundle  

International Nuclear Information System (INIS)

A two-phase flow regime map is developed experimentally and theoretically for a vertical hexagonal flow channel with and without a 36-finned rod hexagonal bundle. This type of flow channel is of interest to MAPLE-type nuclear research reactors. The flow regime maps are determined by visual observations and observation of waveforms shown by a capacitance-type void fraction meter. The experimental results show that the inclusion of the finned hexagonal bundle shifts the flow regime transition boundaries toward higher water flow rates. Existing flow regime maps based on pipe flow require slight modifications when applied to the hexagonal flow channel with and without a MAPLE-type finned hexagonal bundle. The proposed theoretical model agrees well with experimental results.

1997-01-01

58

Unsteady MHD micro polar flow and heat transfer over a vertical porous moving plate with variable suction  

Energy Technology Data Exchange (ETDEWEB)

The unsteady two-dimensional laminar flow of a viscous incompressible electrically conducting micro polar fluid via a porous medium past a semi-infinite vertical porous moving plate in the presence of a transverse magnetic field is studied. A uniform magnetic field acts perpendicularly to the porous surface in which absorbs the micro polar fluid with a suction velocity varying with time. The effects of material parameters on the velocity and temperature fields across the boundary layer are investigated. The method of solution can be applied for small perturbation approximation. Numerical results of velocity and temperature distributions of micro polar fluids are compared with the corresponding flow problems for a Newtonian fluid. (author)

2001-07-01

59

The effects of temperature dependent viscosity and thermal conductivity on unsteady MHD convective heat transfer past a semi-infinite vertical porous moving plate with variable suction  

British Library Electronic Table of Contents (United Kingdom)

In this article, we studied the effects of variable viscosity and thermal conductivity on an unsteady two-dimensional laminar flow of a viscous incompressible conducting fluid past a semi-infinite vertical porous moving plate taking into account the effect of a magnetic field in the presence of variable suction. The fluid viscosity is assumed to vary as an inverse linear function of temperature but the thermal conductivity is assumed to vary as a linear function of temperature. It is assumed that the porous plate moves with a constant velocity in the direction of fluid flow, and the free stream velocity follows the exponentially increasing small perturbation law. The governing equations for the flow are transformed into a system of nonlinear ordinary differential equations by perturbation ...

2007-01-01

60

Evaporation in forced convection of an Ostwaldian permanent laminar film flowing over an isothermal inclined plane surface; Evaporation en convection forcee d'un film liquide mince ostwaldien ruisselant en regime laminaire permanent sur une surface plane isotherme et inclinee  

Energy Technology Data Exchange (ETDEWEB)

The authors study, in forced convection, the evaporation of an Ostwaldian film flowing over an isothermal inclined plane surface to determine the influence of the behaviour index of the liquid on the dynamic and thermal characteristics of liquid-air system. The liquid flow is considered partially two-dimensional whereas for the air it is two-dimensional. The coupled equations with the interfacial conditions are solved using a fully implicit finite differences method. From the study, it appears that the behaviour index influences considerably the transfers which are more important for pseudo-plastic liquids than for dilatant ones. (authors)

2003-12-01

61

Optimum profiles for asymmetrical longitudinal fins in annular ducts  

Energy Technology Data Exchange (ETDEWEB)

In the present work the geometry of annular ducts with asymmetrical longitudinal fins is optimized in order to enhance the heat transfer under laminar coolant flow conditions. The heat transferred is also maximized for a given amount of material or hydraulic resistance. Polynomial profiles are assigned to the two lateral fin surfaces. Velocity and temperature distributions on the annular duct cross section are determined with the help of a finite-element model. A global heat transfer coefficient and an equivalent Nusselt number are then calculated. Lastly, optimum asymmetrical fins obtained by means of a genetic algorithm are shown for different situations and their performance is compared with those of optimum symmetrical fins.

2000-04-01

62

Laboratory robotics projects in the Analytical Development Division at the Savannah River Laboratory  

International Nuclear Information System (INIS)

To encourage the application of robotics technology for routine radiobench applications, a laboratory dedicated to the research and development of contained robotic systems is being constructed. The facility will have several robots located in laminar flow hoods, and the hoods are being designed to allow the possibility for multiple robots to work together. This paper presents both the design features of the hoods and the general layout of the laboratory, and also discusses an application of a robotic system for the routine nuclear counting of gamma tube samples. The gamma tube system is presently operating in one of the routine analysis laboratories. 5 figs.

63

Control device in a reactor  

International Nuclear Information System (INIS)

Purpose: To flatten temperature distribution of coolant within a core. Constitution: The control device of the present invention is to vary reactivity of a fast breeder to control a reactor power. In general, the control device of this kind comprises a guide pipe arranged within the core and a control rod movable up and down within the guide pipe, and a coolant flows from bottom toward top within the guide pipe. Since a cooling flow rate has a margin, temperature of coolant outlet is extremely low as compared to a fuel assembly, and therefore temperature gradient in the vicinity of the top of the control rod becomes sharp to possibly impart thermal shock to the structural material. In the present invention, the flow passage of coolant is varied to thereby avoid outflow thereof into the core, thus flattening the temperature distribution of the coolant within the ...

64

Modelling of Aquitaine II pipe whipping test with the EUROPLEXUS fast dynamics code  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a numerical simulation with the EUROPLEXUS fast dynamics software of a pipe whipping phenomenon occurring in the thermal hydraulic conditions of a loss of coolant accident in a PWR primary circuit. Different physical phenomena take place simultaneously during the rupture and the whipping of the pipe such as plasticity, contact, large displacements, two-phase flow regime and fluid structure interaction. Two kinds of numerical models - a simplified pipeline model and a mixed 1D/3D model - are considered and compared throughout modelling and computation. Numerical results are compared with experimental data belonging to the Aquitaine II test campaign.

2005-08-01

65

Pulsatile viscous flow in a curved pipe: Effects of pulsation on the development of secondary flow  

International Nuclear Information System (INIS)

This work presents an experimental and numerical study of pulsated Dean flow, three-dimensional pulsatile flow in a curved pipe. The numerical study is performed by CFD code (Fluent 6) in which a pulsated velocity field is imposed as an inlet condition. The experimental setup involves principally a 'Scotch-yoke' pulsatile generator and a 90o bend. Laser Doppler Velocimetry (LDV) measurements have shown that the Scotch-yoke generator produces pure sinusoidal instantaneous mean velocities with a mean deviation of 3%. Visualizations by laser-induced fluorescence (LIF) and velocity measurements, coupled with the numerical results, have permitted analysis of the evolution of the swirling secondary flow structures that develop along the bend during the pulsation phase. These measurements were made for a range of stationary Reynolds number (300?Rest?1200), frequency parameter (1??=r0(?/?)1/2max,osc/Ust). We ...

2010-10-01

66

Steam-water two-phase flow in large diameter vertical piping at high pressures and temperatures  

Energy Technology Data Exchange (ETDEWEB)

No information on steam/water two-phase flow behavior in large diameter pipes (10 inch or larger) at elevated pressures is available in the open literature. However, there are many applications, in the nuclear, chemical and petroleum industries among others where two-phase flows in large diameter pipes at elevated pressures and temperatures are encountered routinely or under accident scenarios. Experimental data on steam-water two-phase flow in a large diameter (20 inch, 50.08 cm I.D.) vertical pipe at elevated pressures and temperatures (2.8 MPa/230 C--6.4 MPa/280 C) have been obtained. Void fraction, two-phase mass flux, phase and velocity distributions as well as pressure drop along the test pipe have been measured using the Ontario Hydro Technologies (OHT) Pump Test Loop. The void fraction distributions were found to be axially symmetric ...

1996-08-01

67

Steam-water two-phase flow in large diameter vertical piping at high pressures and temperatures  

International Nuclear Information System (INIS)

No information on steam/water two-phase flow behavior in large diameter pipes (10 inch or larger) at elevated pressures is available in the open literature. However, there are many applications, in the nuclear, chemical and petroleum industries among others where two-phase flows in large diameter pipes at elevated pressures and temperatures are encountered routinely or under accident scenarios. Experimental data on steam-water two-phase flow in a large diameter (20 inch, 50.08 cm I.D.) vertical pipe at elevated pressures and temperatures (2.8 MPa/230 C--6.4 MPa/280 C) have been obtained. Void fraction, two-phase mass flux, phase and velocity distributions as well as pressure drop along the test pipe have been measured using the Ontario Hydro Technologies (OHT) Pump Test Loop. The void fraction distributions were found to be axially symmetric ...

1996-03-10

68

New advances in mitigating environmental impact of pipe-type cables  

Energy Technology Data Exchange (ETDEWEB)

Through a comprehensive and aggressive research program Consolidated Edison Company of New York, Inc. (Con Edison) has designed, developed, and installed several new products to address the environmental impact of dielectric fluid from pipe-type cable systems. These include: On Line Leak Detection, Leak Location, Retractable Flow Direction Indicator, Full Stop Joints, and Transition Joints. This paper describes the application of the aforementioned products on the Con Edison underground transmission system.

1999-04-01

69

Enhanced heat transfer through oscillatory flow  

Energy Technology Data Exchange (ETDEWEB)

The enhancement of longitudinal heat transfer by means of fluid pulsation in a pipe has been investigated analytically and numerically, including the transient state. The effects of pulsation amplitude, frequency, and pipe length on thermal properties such as effective thermal diffusivity and delay time are clarified. Their effects on numerical calculations are also presented and suggestions for efficient numerical calculations of this problem are made concerning the combination of parameters.

1994-03-01

70

A study of Two-Phase Flow Regime Maps in Vertical and Horizontal Pipes  

Energy Technology Data Exchange (ETDEWEB)

A safety analysis code to design a pressurized water reactor and to obtain the licences including entire proprietary rights is under development in domestic research and development project. The purpose and scope of this report is to develop the flow regimes related models for inter-phase friction, wall frictions, wall heat transfer, and inter-phase heat and mass transfer in two-phase three-field equations. In order to choose choose the flow regime criteria, we have investigated various exiting best-estimate T/H codes in this chapter 2. They are the RELAP5-3D, TRAC-M, CATHARE, MARS codes. Around 500 references used in these codes have been collected and reviewed. Also we have investigated eleven papers in detail. In chapter 3, based on the selected flow regimes, the flow regime maps for a gas-liquid flow in horizontal and vertical tubes have decided including the mechanisms of ...

2007-10-15

71

Oil and Natural Gas Technology: Development of Next Generation Multiphase Pipe Flow Prediction Tools. Final Report.  

Science.gov (United States)

The developments of fields in deep waters (5000 ft and more) is a common occurrence. It is inevitable that production systems will operate under multiphase flow conditions (simultaneous flow of gas-oil-and water possibly along with sand, hydrates, and wax...

2008-01-01

72

Development of Next Generation Multiphase Pipe Flow Prediction Tools. Semi-Annual Technical Report. Reporting Period: June 2006 through November 2006.  

Science.gov (United States)

The developments of oil and gas fields in deep waters (5000 ft and more) will become more common in the future. It is inevitable that production systems will operate under multiphase flow conditions (simultaneous flow of gas-oiland water possibly along wi...

2007-01-01

73

Demonstration and Evaluation of Magnetic Descalers.  

Science.gov (United States)

Mineral scale formation in water distribution piping impedes flow, resulting in pressure and volume reduction and increasing operational costs. Chemical cleaning is both costly and time consuming, and there are health concerns when chemically cleaning pot...

2001-01-01

74

Heat and momentum transport in self-sustained oscillatory viscous flows  

Energy Technology Data Exchange (ETDEWEB)

Heat and momentum transport in self-sustained oscillatory viscous flows is investigated by direct numerical simulation using the spectral element method. Above a critical Reynolds number, these flows bifurcate to a time-periodic, self-sustained oscillatory state. Traveling waves are observed, even at moderately low Reynolds numbers, inducing self-sustained oscillations that result in very well-mixed flows, which, in turn, lead to convective heat transfer augmentation. These oscillatory states are investigated and correlations between the time- and space-averaged Nusselt and Reynolds numbers are obtained. The transport phenomena of heat and momentum due to the oscillatory components of the flow are analyzed by looking at the phase portraits of velocity and temperature, investigating the behavior of the terms involving their fluctuations, as well as considering the correlation coefficients between the ...

1992-11-01

75

The effect of the shear rate-dependent thermal conductivity of non-Newtonian fluids on the heat transfer in a pipe flow  

Science.gov (United States)

The present study investigates the effect of the shear rate-dependent thermal conductivity of non-Newtonian fluids on the heat transfer enhancement in a pipe flow. The constant heat flux as thermal boundary condition was adopted in the thermally developed region. The present analytical results show the heat transfer enhancement over those of a shear rate-independent thermal conductivity fluid. The heat transfer coefficient ratio (h/h{sub 0}) linearly increase with the non-dimensional average velocity difference which is the product of the shear rate-dependence of the thermal conductivity and wall-shear rate.

1996-09-01

76

Transient simulation of a catalytic converter for a dual fuel engine  

Energy Technology Data Exchange (ETDEWEB)

A catalytic converter of a ceramic monolith honeycomb substrate, coated with a washcoat of catalyst and attached to a natural gas/diesel dual fuel engine was simulated and studied experimentally. The paper describes the application of one-dimensional finite element model for the transient and steady state operation. Laminar flow was approximated using a dispersed plug flow model, and chemical kinetics were simulated using LHHW (Langmuir/ Hinshelwood/ Hougan/ Watson) type expressions. Simulation results were compared with experimental results for heating and cooling cycles which resulted from speed and load changes on the engine. The comparison showed a maximum difference between the two sets of emission levels of about 10 per cent, showing that the one-dimensional model is acceptable model for this dual fuel engine converter combination. 50 refs., 3 tabs., 13 figs.

2000-06-01

77

An investigation of turbulent catalytically stabilized channel flow combustion of lean hydrogen - air mixtures  

Energy Technology Data Exchange (ETDEWEB)

The catalytically stabilised thermal combustion (CST) of lean hydrogen-air mixtures was investigated numerically in a turbulent channel flow configuration using a two-dimensional elliptic model with detailed heterogeneous and homogeneous chemical reactions. Comparison between turbulent and laminar cases having the same incoming mean properties shows that turbulence inhibits homogeneous ignition due to increased heat transport away from the near-wall layer. The peak root-mean-square temperature and species fluctuations are always located outside the extent of the homogeneous reaction zone indicating that thermochemical fluctuations have no significant influence on gaseous combustion. (author) 4 figs., 6 refs.

1999-08-01

78

Coolant rate distribution in horizontal steam generator under natural circulation  

International Nuclear Information System (INIS)

The interrelations between the factors causing the main effects on the primary circuit coolant flow rate distribution in the horizontal steam generator pipes in reactor facilities with the WWER type reactors under the modes with natural circulation are discussed. The criterion showing the presence or absence of coolant circulation reversal in bottom rows of the steam generator pipes is obtained. It is shown that large hydraulic non-uniformity in steam generator pipes operating in parallel under coolant natural circulation leads to decreasing the heat transfer surface efficiency under reactor facility emergency cooling, restricts its servicing capabilities. The circulation reverse in steam generator pipes under coolant natural circulation mode can give unfavourable effect on separate structural elements of the steam generators and as a result it can cause additional temperature ...

1997-09-01

79

Wall thinning trend analyses for secondary side piping of Korean NPPs  

International Nuclear Information System (INIS)

Since the mid-1990s, nuclear power plants in Korea have experienced wall thinning, leaks, and ruptures of secondary side piping caused by flow-accelerated corrosion (FAC). The pipe failures have increased as operating time progresses. In order to prevent the FAC-induced pipe failures and to develop an effective FAC management strategy, KEPRI and KOPEC have conducted a study for developing systematic FAC management technology for secondary side piping of all Korean nuclear power plants. As a part of the study, FAC analyses were performed using the CHECWORKS code. The analysis results were used to select components for inspection and to determine inspection intervals on each nuclear power plant. This paper describes the introduction of the FAC analysis method and the wall thinning trend analysis results by reactor type, system, and water treatment amine. This paper also represents the ...

2003-08-17

80

Gas-fired boiler plant  

Energy Technology Data Exchange (ETDEWEB)

A gas-fired boiler plant comprises a burner bed extending over a flat surface and heat exchanger pipes arranged above the burner bed, parallel to the said surface. The heat exchanger tubes comprise pipes equipped with a pluraltiy of flat ribs which extend substantially radially from the said pipes and which are provided in space arrangement over the length of the said heat exchanger pipes. The ribs are provided with bent-off portions. The hot flue gases rising from the burner bed flow through the gaps formed between the said ribs and pipes. In order to improve both the convective heat transmission and the utilization of the radiant heat, the bent-over edges are inclined, at least partly, relative to the surface of said burner bed, the arrangement being selected in a manner to ensure that bent-over portions point towards the burner bed and the rising flue gased ...

1989-10-10

81

Two-phase flow regime characterization in a PWR hot leg with candy cane geometry  

International Nuclear Information System (INIS)

This paper describes a series of tests investigating two-phase flow regimes in a transparent model of a PWR hot leg. Test conditions were selected to cover a wide range of gas and liquid superficial velocities (.01 m/s 2 m/s) were also performed for comparison with semi-analytical predictions. Results include average void fractions, flow rates, and visual characterizations of the two-phase flow phenomena. Results show generally good agreement with Taitel and Duckler flow regime map and Zuber-Findlay correlation for average void fraction in vertical pipes. Results also indicate that flow regimes and collapsed liquid level (void fraction) are more strongly dependent on air flow rate (air superficial velocity) than water flow rate (water superficial velocity).

1984-10-01

82

An Experimental study on a Method of Computing Minimum flow rate  

International Nuclear Information System (INIS)

Many pump reliability problems in the Nuclear Power Plants (NPPs) are being attributed to the operation of the pump at flow rates well below its best efficiency point(BEP). Generally, the manufacturer and the user try to avert such problems by specifying a minimum flow, below which the pump should not be operated. Pump minimum flow usually involves two considerations. The first consideration is normally termed the 'thermal minimum flow', which is that flow required to prevent the fluid inside the pump from reaching saturation conditions. The other consideration is often referred to as 'mechanical minimum flow', which is that flow required to prevent mechanical damage. However, the criteria for specifying such a minimum flow are not clearly understood by all parties concerned. Also various factor and information for ...

2009-10-01

83

An Experimental Study of Oil / Water Flow in Horizontal Pipes  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this thesis is to study the behaviour of the simultaneous flow of oil and water in horizontal pipes. In this connection, two test facilities are used. Both facilities have horizontal test sections with inner pipe diameters equal to 2 inches. The largest facility, called the model oil facility, has reservoirs of 1 m{sub 3} of each medium enabling flow rates as high as 30 m{sub 3}/h, which corresponds to mixture velocities as high as 3.35 m/s. The flow rates of oil and water can be varied individually producing different flow patterns according to variations in mixture velocity and input water cut. Two main classes of flows are seen, stratified and dispersed. In this facility, the main focus has been on stratified flows. Pressure drops and local phase fractions are measured for a large number of ...

2001-07-01

84

An investigation into flow regimes for two-phase helium flow  

Energy Technology Data Exchange (ETDEWEB)

The Tevatron accelerator at Fermilab incorporates long two-phase helium passages. During magnet design, the generalized flow map of Baker was used to predict homogeneous flow. Longer than expected magnet time constants led to this investigation. The importance of predicting the flow regime has been amplified with the advent of non-horizontal accelerator designs. A test setup was constructed at Fermilab to investigate two-phase helium flow regimes for conditions practical in accelerator designs. The setup consisted of a standard Tevatron satellite refrigerator, subcooling dewar, heater, 35 m long transfer line, and a specialized end box. A knife blade on the midplane of the transfer line diverted the flow from the upper and lower halves of the pipe to separate vessels in the end box. The amount of liquid above and below the plane was measured at various total ...

1987-10-01

87

Experimental investigation of premixed combustion within highly porous media  

International Nuclear Information System (INIS)

This paper reports on an experimental investigation of premixed methane/air combustion stabilized within a reticulated partially stabilized zirconia foam burner that was performed. A flame holder was used to extend the stability range to allow a stable flame to be maintained for a variety of flow rate and equivalence ratio combinations. The stability range, temperature distributions, and emissions were examined over a range of equivalence ratios and flow rates. The flame was found to be axisymmetric for all conditions in which the reactants were sufficiently well mixed and the flow distribution was sufficiently uniform. Burning speeds were measured that were well in excess of the laminar flame speed. The axial temperature distribution (measured around the burner annulus) in the postflame zone was found to be relatively insensitive to flow rate but dependent upon the burner core ...

1991-03-17

88

Method of feeding a coolant into a reactor  

International Nuclear Information System (INIS)

Object: To suppress a quantity of impurities in a coolant fed into a reactor vessel. Structure: The concentration of oxygen in a coolant flowing from a condensation desalting instrument into a feed and condensation piping is measured by an oxygen-concentration detector to feed its signal to an adjusting instrument. A degree of opening of an oxygen flow control valve to maintain the concentration of oxygen in the cooling water flowing within the pipe in the range from about 10 to about 200 ppb. Also, the concentration of oxygen in the cooling water fed to the desalting instrument is maintained at a level less than 2 ppb. Thereby, the total amount of iron flown into the vessel can be suppressed to a fine amount such as less than about 1 ppb. (Kawakami, Y.).

89

Effect of Cr content, hardness and micro structure on flow-accelerated corrosion in carbon steel pipes. Examination of replaced carbon steel pipes  

International Nuclear Information System (INIS)

68 replaced carbon steel piping in secondary system of pressurized water reactor (PWR) has been investigated by visual examination for checking thinning conditions. It is well known that the flow-accelerated corrosion (FAC) was inhibited by traces of Cr in steel. Therefore, the chemical compositions of those steels have been measured. In addition, the micro structure and hardness of those steels have been investigated. And the relationship between those material variables and FAC rate was considered. As the results, (1) The Cr contents in those steels were below 0.1 wt% except one sample. Minute quantities of chromium increase the resistance against FAC. But the water velocity was thought to be the dominant factor rather than chemical composition in steel, at least such as below 0.1%Cr. (2) Hardness of all piping has been satisfied the specifications of each materials. The hardness of steels was not correlated with wall ...

2008-10-01

90

The effect of a concurrent gas flow on gas-liquid mass transfer  

Science.gov (United States)

A theory for the mass transfer process was developed. It was assumed that the largest convective motions in the flow control the rate of mass transfer. Measurements of mass transfer coefficients for the absorption of oxygen by water films were made for concurrent flows in a horizontal rectangular channel, and for concurrent and free-falling downflow in a one-inch pipe. The measured values of the Sherwood number for concurrent flows were up to three times as great as would be predicted from this relation. This increase in Sherwood number was correlated with a dimensionless group similar to a Martinelli parameter which is characteristic of two phase flows. An explanation for this effect is given in terms of the way that the scales of the convective motions are related to bulk flow parameters.

1977-01-01

91

The Australian Geographic Team Marsupial solar-powered car  

Energy Technology Data Exchange (ETDEWEB)

As in all vehicles of this type, low weight and aerodynamic drag must be achieved without compromising safety, and in an extremely rugged structure. This has been done by using a chrome-molybdenum steel space-frame, surrounded by a Kevlar/foam sandwich body shell. The solar panel wing, which uses a laminar flow section to obtain low drag, does not tilt except when the vehicle is stationary. A high degree of redundancy is built into the vehicle; for example there are two motors and transmissions, the solar array is divided into seven parallel sub-arrays, and the power electronics is multiply redundant. Built entirely in the garage of a suburban house, the Australian Geographic Team Marsupial car cost less than US$50,000 to construct.

1988-01-01

92

Role of the diffuse layer in acidic and alkaline fuel cells  

British Library Electronic Table of Contents (United Kingdom)

A numerical model is developed to study electrolyte dependent kinetics in fuel cells. The model is based on the Poisson-Nernst-Planck (PNP) and generalized-Frumkin-Butler-Volmer (gFBV) equations, and is used to understand how the diffuse layer and ionic transport play a role in the performance difference between acidic and alkaline systems. The laminar flow fuel cell (LFFC) is used as the model fuel cell architecture to allow for the appropriate comparison of equivalent acidic and alkaline systems. We study the overall cell performance and individual electrode polarizations of acidic and alkaline fuel cells for both balanced and unbalanced electrode kinetics as well as in the presence of transport limitations. The results predict cell behavior based on electrolyte composition that strongly...

2011-01-01

93

Parametric study of pulsed thermal bumps in supersonic boundary layer  

British Library Electronic Table of Contents (United Kingdom)

A three-dimensional numerical study is performed to explore the effect of pulsed spanwise-periodic surface thermal perturbation (also denoted as thermal bump) in a Mach 1.5 flat plate laminar boundary layer. A high-resolution upwind-biased Roe method is used with the compressive Van Leer harmonic limiter on a suitably refined mesh. The dependence of flow stability characteristics on the variation of thermal bump geometry (shape and dimension) and pulsing properties (disturbance amplitude and frequency) is assessed. It is shown that the finite-span thermal bumps generate streamwise vortices. When the thermal bump is pulsed, vortex shedding is observed, and the streamwise vorticity grows with the downstream distance. Analysis of the integrated disturbance energy indicates that the streamwise...

2011-01-01

94

Loaded Transducer Fpr Downhole Drilling Component  

Energy Technology Data Exchange (ETDEWEB)

A robust transmission element for transmitting information between downhole tools, such as sections of drill pipe, in the presence of hostile environmental conditions, such as heat, dirt, rocks, mud, fluids, lubricants, and the like. The transmission element maintains reliable connectivity between transmission elements, thereby providing an uninterrupted flow of information between drill string components. A transmission element is mounted within a recess proximate a mating surface of a downhole drilling component, such as a section of drill pipe. To close gaps present between transmission elements, transmission elements may be biased with a "spring force," urging them closer together.

2005-07-05

95

Structural integrity of whipping pipes following postulated rupture - a contribution to strain levels acceptable under faulted conditions. Integritaetsverhalten von Rohrleitungen nach unterstelltem Rundabriss - ein Beitrag zur Dehnungsabsicherung bei Schadensfaellen  

Energy Technology Data Exchange (ETDEWEB)

By tests about pipe failure under extreme bending, moment at cross sections affected by circumferential cracks, admissible strains for securing the integrity in the area of a flow link are indicated. These are 7% for austenic and ferritic materials in the undisturbed cross section. From d/t-ratios of 20 onwards the strains are limited by pipe bulging on the pressure-load side. In this connection, circumferential flaws do not have any influence on the behaviour on the strained side, when their expansion does not exceed the investigated limitis of <60 circumferential expansion and crack depth of 0,3 t. (orig.)

1991-01-01

96

Asymptotic rate of decay of turbulence in a tube following a combustion-induced step in temperature  

Energy Technology Data Exchange (ETDEWEB)

Combustion in a ceramic tube produces a nearly discontinuous change in temperature of the premixed fuel and air at the flame front, from room temperature up to the adiabatic flame temperature ([approximately]2,100 K). The upstream Reynolds number for a stable flame in a 9.5-mm tube is in the range of 3,000-6,000, corresponding to turbulent flow. Owing to property changes that accompany the severe increase in temperature at the flame front, the downstream Reynolds number is reduced below the transitional value ([approximately]2,100); consequently the turbulence decays while the velocity profile approaches the parabolic one characteristic of laminar flow. A previous study of ours revealed that, far downstream from the flame front, the turbulent energy decayed exponentially with downstream distance. This paper examines the asymptotic behavior of the k-[epsilon] model and compares the results to that for two-dimensional ...

1993-07-01

97

Fundamental study of heat transfer augmentation by smooth turbulence surface promotors  

International Nuclear Information System (INIS)

In the utilization of the thermal energy by ocean temperature difference and factory waste heat, the high performance heating surfaces in pipes from which scale can be removed are required. As the method of removing scale, the method using sponge balls seems most suitable, but for applying this method, as the form of the protrusions attached to the inner surfaces of pipes, smooth circular are form is desirable. The promotion of heat transfer with the rows of circular arc protrusions like this is strongly related to the mode of flow and such structure as separation, recirculation flow, readhesion and turbulent energy generation. In this study, as the basic research to optimize the heating surface with the rows of smooth protrusions, the flow characteristics and the heat transfer characteristics including the turbulent structure of the wake of protrusions were experimentally ...

1985-01-01

98

Three-dimensional numerical simulation of temperature field and helium flow field in ITER China TBM  

International Nuclear Information System (INIS)

Three dimensional temperature field and helium flow field of TBM are simulated using the general purpose computational fluid dynamics (CFD) code FLUENT. The temperature distribution of Be Armor, Be Pebble Bed, Li_4SiO_4 Pebble Bed, Structure Material of TBM, and helium flow field in the cooling pipe are presented. The research indicates that the work temperature of each material is under the material temperature allowed except some places where high temperature should be excluded in the design. The results will provide references for further optimized thermal hydraulic design of ITER China TBM. (authors)

2006-02-01

99

Determination of two-phase flow parameters for nuclear fuel channels using a real-time neutron radiography method  

Energy Technology Data Exchange (ETDEWEB)

Multi-dimensional modelling of two-phase flow requires accurate constitutive relationships for interfacial parameters such as interfacial heat transfer, void fraction distribution, interfacial area, etc. However, existing diagnostic systems for measurement of two-phase flow parameters have difficulty measuring two or three-dimensional void distributions required for determination of interfacial parameters. In this work, a Real-Time Neutron Radiography (RTNR) system is developed for non-intrusive measurement of two-phase flow parameters in nuclear fuel channels at low thermal neutron fluxes (on the order of 10{sup 6}n/cm{sup 2}-s). This advanced radiation technique has the advantage of measuring two-phase flow in 3 1/2 dimensions (x,{integral}dy,t) where the 1/2 dimension refers to an integrated or averaged space dimension. Pipe flow channels, annulus ...

1995-07-01

100

Determination of two-phase flow parameters for nuclear fuel channels using a real-time neutron radiography method  

International Nuclear Information System (INIS)

Multi-dimensional modelling of two-phase flow requires accurate constitutive relationships for interfacial parameters such as interfacial heat transfer, void fraction distribution, interfacial area, etc. However, existing diagnostic systems for measurement of two-phase flow parameters have difficulty measuring two or three-dimensional void distributions required for determination of interfacial parameters. In this work, a Real-Time Neutron Radiography (RTNR) system is developed for non-intrusive measurement of two-phase flow parameters in nuclear fuel channels at low thermal neutron fluxes (on the order of 10"6n/cm"2-s). This advanced radiation technique has the advantage of measuring two-phase flow in 3 1/2 dimensions (x,#integral#dy,t) where the 1/2 dimension refers to an integrated or averaged space dimension. Pipe flow channels, annulus ...

1346-01-01

101

Effect of water chemistry improvement on flow accelerated corrosion in light-water nuclear reactor  

International Nuclear Information System (INIS)

Flow Accelerated Corrosion (FAC) of Carbon Steel (CS) piping has been one of main issues in Light-Water Nuclear Reactor (LWRs). Wall thinning of CS piping due to FAC increases potential risk of pipe rupture and cost for inspection and replacement of damaged pipes. In particular, corrosion products generated by FAC of CS piping brought steam generator (SG) tube corrosion and degradation of thermal performance, when it intruded and accumulated in secondary side of PWR. To preserve SG integrity by suppressing the corrosion of CS, High-AVT chemistry (Feedwater pH9.8#+-#0.2) has been adopted to Tsuruga-2 (1160 MWe PWR, commercial operation in 1987) in July 2005 instead of conventional Low-AVT chemistry (Feedwater pH 9.3). By the High-AVT adoption, the accumulation rate of iron in SG was reduced to one-quarter of that under conventional Low-AVT. As a result, a ...

2009-10-01

102

Electrohydrodynamic pumping in cable pipes. Final report  

Energy Technology Data Exchange (ETDEWEB)

Many oil-insulated electric power cables are limited by heat buildup caused in part by the low thermal conductivity of the oil. Circulation of the oil is known to reduce the cable temperature, but can lead to excessive pressure buildup on long cables when using conventional pumping methods. An alternate pumping method using distributed electric fields to avoid this pressure buildup is described. Electrohydrodynamic (EHD) pumping was studied both theoretically and experimentally for possible application in underground cable cooling. Theoretical studies included both analytical and finite-element analysis of the flow patterns driven by travelling electric fields. Experimentally, flow rates in a cable-pipe model were measured under a wide variety of operating conditions. Theory and experiment are in agreement for velocities below 10 cm/s, but higher velocities could not be reached in the experiment, due to increased ...

1983-02-01

103

Control rod devices  

International Nuclear Information System (INIS)

Purpose: To remove excessive driving pressure applied to an unisolated control rod drive by returning excessive coolant to a condensed water storage tank or to the inlet side of a drive water pump using a coolant flow rate control pipe of a control rod driving hydraulic system. Constitution: Excessive water is returned to a condensed water tank while controlling the excessive coolant by a flow control valve in response to variations in the pressure difference between the reactor pressure and the driving water line when the control rods are isolated using a pipe from the outlet side of the drive water pump to the condensed water storage tank. Thus, the control rod to be isolated is prevented form being dropped. (Sekiya, K.).

104

Fundamental study on the convective heat transfer augmentation of a wavy type heat exchanger  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the study is to investigate the heat transfer augmentation method for a wavy channel type heat exchanger. Experimental studies were carried out, by installation of flow guide-plates with simple structure, to clarify the effects on the augmentation whether the effects are brought by the flow acceleration or by the increase of intensity of turbulence due to the flow seperation, and to determine optimum shape of flow guide-plates. The shape and dimensions of the experimental apparatus are as follows; channel width H of 30 mm, rectangular section with breadth of 300 mm, wavy duct with a bend angle of 60/sup 0/ and straight pipe of 2H length. Air stream was flowed through the duct with Reynolds number of 1.7 x 10/sup 4/ only. As the results, following conclusions were obtained. (1) Wavy duct with large bend angle and without inserting ...

1988-06-25

105

Corrosion on stainless steel in high concentrated sulphuric acid under flow- and fatigue loading conditions. Stroemungs- und schwingungsbeeinflusste Korrosion von nichtrostenden Staehlen in konzentrierter Schwefelsaeure; Schlussbericht  

Energy Technology Data Exchange (ETDEWEB)

It was to be investigated why inexplicable cracking occurred in plain stainless austenitic steel pipes of heat exchangers in discrete sites of the inner surface exposed to acid even with anodic corrosion protection, and what countermeasures must be taken. The following materials were investigated: X 6 CrNiTi 18 10 and X 6 CrNiMoTi 17 12 2. The influence of mechanical vibrations on passive film formation and destruction was investigated in unconstrained pipes and pipes constrained at one end in conditions of anodic protection at frequencies of 0 to 160 Hz and temperatures of 98 to 130 degrees Centigrade in 98% sulphuric acid. The authors were unable to reconstruct the cracks observed in practical operation in anodically protected heat exchanger pipes of stainless austenitic steel. (orig./MM). 5 refs., 2 tabs., 71 figs.

1990-09-20

106

Unsteady state heat transfer in the vertical walls of a building  

Energy Technology Data Exchange (ETDEWEB)

The unsteady state heat transfer behaviour of a vertical wall subject to the effects of uniform radiation is investigated and the dimensional analysis of combined heat transfers by conduction, convection and radiation is presented. The convective heat transfer coefficients used in the numerical model are determined experimentally by means of an assembly resembling the conditions encountered in the dwelling (variable temperatures and heat flows in time and space, wall associated with a floor, radiative flux outside the wall). In routine conditions (homogeneous wall dimensions, temperature differentials less than 40/sup 0/C), it is shown that the problem depends in practice on three parameters (instead of five) and that nomographs can give the energy accumulated in the wall as a function of its geometric and thermal charactersitics and the external conditions (type and thickness of material, changes in incident flux, convection over the height of the wall in ...

1982-12-01

107

Process model for carbothermic production of silicon metal  

Energy Technology Data Exchange (ETDEWEB)

This thesis discusses an advanced dynamical two-dimensional cylinder symmetric model for the high temperature part of the carbothermic silicon metal process, and its computer encoding. The situation close to that which is believed to exist around one of three electrodes in full-scale industrial furnaces is modelled. This area comprises a gas filled cavity surrounding the lower tip of the electrode, the metal pool underneath and the lower parts of the materials above. The most important phenomena included are: Heterogeneous chemical reactions taking place in the high-temperature zone (above 1860 {sup o}C), Evaporation and condensation of silicon, Transport of materials by dripping, Turbulent or laminar fluid flow, DC electric arcs, Heat transport by convection, conduction and radiation. The results from the calculations, such as production rates, gas- and temperature distributions, furnace- and particle geometries, fluid ...

1995-09-12

108

Numerical study of inflow conditions on a turbulent isothermal or heated plane jet; Etude numerique des conditions d'emission sur un ecoulement de type jet plan turbulent isotherme ou chauffe  

Energy Technology Data Exchange (ETDEWEB)

We intend to solve equations governing turbulent plane-vertical isotherm and non isotherm jets by taking into account inflow conditions at the exit of the nozzle. The analysis is focused on the influence of these conditions on this type of flow. Two cases are considered (uniform and parabolic velocity and temperature profiles). A finite difference scheme is developed to solve the governing equations. This numeric model allows us to show that the region of fully developed regime begins much nearer the nozzle for the turbulent case than for the laminar flow case. Indeed, the turbulence increases the mixing between the incoming gas from the nozzle and the ambient fluid, and consequently the size of the potential core zone decreases. The results are compared to other works introducing mathematical variables based on the energy conservation for the case of the mixed convection and the momentum conservation for the forced ...

1999-11-01

109

Dust resuspension and transport modeling for loss of vacuum accidents  

Energy Technology Data Exchange (ETDEWEB)

Plasma surface interactions in tokamaks are known to create significant quantities of dust, which settles onto surfaces and accumulates in the vacuum vessel. In ITER, a loss of vacuum accident may result in the release of dust which will be radioactive and/or toxic, and provides increased surface area for chemical reactions or dust explosion. A new method of analysis has been developed for modeling dust resuspension and transport in loss of vacuum accidents. The aerosol dynamic equation is solved via the user defined scalar (UDS) capability in the commercial CFD code Fluent. Fluent solves up to 50 generic transport equations for user defined scalars, and allows customization of terms in these equations through user defined functions (UDF). This allows calculation of diffusion coefficients based on local flow properties, inclusion of body forces such as gravity and thermophoresis in the convection term, and user defined source terms. The code accurately reproduces ...

2007-07-01

110

Dust resuspension and transport modeling for loss of vacuum accidents  

International Nuclear Information System (INIS)

Plasma surface interactions in tokamaks are known to create significant quantities of dust, which settles onto surfaces and accumulates in the vacuum vessel. In ITER, a loss of vacuum accident may result in the release of dust which will be radioactive and/or toxic, and provides increased surface area for chemical reactions or dust explosion. A new method of analysis has been developed for modeling dust resuspension and transport in loss of vacuum accidents. The aerosol dynamic equation is solved via the user defined scalar (UDS) capability in the commercial CFD code Fluent. Fluent solves up to 50 generic transport equations for user defined scalars, and allows customization of terms in these equations through user defined functions (UDF). This allows calculation of diffusion coefficients based on local flow properties, inclusion of body forces such as gravity and thermophoresis in the convection term, and user defined source terms. The code accurately reproduces ...

2007-10-05

111

Accurate, stable, explicit, parabolized navier-stokes solver for high speed flows  

Energy Technology Data Exchange (ETDEWEB)

A stable, accurate, and efficient implementation of MacCormack's explicit algorithm for the Parabolized Navier-Stokes equations is demonstrated. The familiar problem of decoding the conservative axial flux vector is solved, resulting in accurate, smooth dependent variable profiles through the viscous-layer sonic line. Source terms due to transformation of the parabolized governing equations into the computational plane and the equations into the computational plane and the resulting metric differencing have been identified and eliminated through inclusion of appropriate geometric conservation law terms. Test cases computed include two- and three-dimensional supersonic and hypersonic flow at laminar and turbulent Reynolds numbers. The computed results demonstrate very good agreement with experiment and with solutions of the full Navier-Stokes equations. Computational times required for the MacCormack explicit PNS code are approximately ...

1986-01-01

112

Identification method for gas-liquid two-phase flow regime based on singular value decomposition and least square support vector machine  

International Nuclear Information System (INIS)

Aiming at the non-stationary characteristics of differential pressure fluctuation signals of gas-liquid two-phase flow, and the slow convergence of learning and liability of dropping into local minima for BP neural networks, flow regime identification method based on Singular Value Decomposition (SVD) and Least Square Support Vector Machine (LS-SVM) is presented. First of all, the Empirical Mode Decomposition (EMD) method is used to decompose the differential pressure fluctuation signals of gas-liquid two-phase flow into a number of stationary Intrinsic Mode Functions (IMFs) components from which the initial feature vector matrix is formed. By applying the singular vale decomposition technique to the initial feature vector matrixes, the singular values are obtained. Finally, the singular values serve as the flow regime characteristic vector to be LS-SVM classifier and flow regimes ...

2007-12-01

113

Horizontal slug flow properties captured by intermittent slug tracking model  

Energy Technology Data Exchange (ETDEWEB)

The oil production is largely transported in pipelines operating in two-phase flow regime. The predominant flow pattern is the slug flow, which is characterized by intermittent succession of liquid slugs followed by long gas bubbles. This paper addresses specifically to the capture of the intermittently feature of slug flows using a compressible slug tracking model. The intermittency rules the bubble to bubble interactions, defines the bubble coalescence rate, changes the size of the bubbles, alters the pressure drop among other flow properties. The inlet sizes and velocities of the bubbles and slugs are estimated based on experimentally determined distributions characterized by its mean value and standard deviation. The inlet intermittency, transmitted through the inlet boundary condition, results in a better match of the fluctuating flow properties along the ...

2008-07-01

114

Fusion ldentification method for gas-liquid two-phase flow regime based on recurrence quantification characteristics  

International Nuclear Information System (INIS)

To increase further the accuracy of flow regime and considering the non-stationary characteristics of differential pressure fluctuation signals of gas-liquid two-phase flow, the flow regime identification method based on recurrence quantification analysis (RQA) and multi-sensor data fusion techniques is put forward. First of all, the recurrence quantification analysis method is used to extract the nonlinear feature parameters of the differential pressure fluctuation signals of gas-liquid two-phase flow, and data fusion of feature layer is conducted by QRA feature parameters of differential pressure signals of three pressure measure intervals, and composes the fusion feature vectors. The fused characteristic vector are input into the support vector machine for identify flow regime. The identification results for four typical flow regimes of air-water two-phase ...

2009-12-01

115

Experimental study on two-phase flow regime transition from stratified to slug flow in a large-height horizontal duct  

Energy Technology Data Exchange (ETDEWEB)

The prediction of two-phase flow regime in the horizontal pipings during a loss-of-coolant accident (LOCA) is important for safety analysis of a pressurized water reactor (PWR). The flow regime transition conditions for a horizontal two-phase air-water flow were studied using a large-height, horizontal rectangular duct test section. The duct dimensions were 700 mm in height, 100 mm in width and 28.3 m in length. The experimental criterion for the flow regime transition from the stratified to slug flow regimes, in terms of the local void fraction and the non-dimensional gas-liquid relative velocity, agreed qualitatively with the prediction by the Mishima-Ishii model that is based on an idea that the interfacial waves with the largest growth rate will develop into a slug. However, the transition in the experiment occurred at systematically lower (by about 40 %) ...

1992-02-01

116

Transient analysis of blowdown thrust force under PWR LOCA conditions  

Energy Technology Data Exchange (ETDEWEB)

The analytical results of blowdown characteristics and its thrust force were compared with the experiment, which were performed as pipe whip tests under the PWR LOCA conditions on the hypothetical accident of guillotine break of pipes. The blowdown thrust force was obtained by the integral momentum equation about single-phase flow, homogeneous and separated two-phase flow, assuming critical pressure at the exit if critical flow condition was satisfied. The following results are obtained: (1) The node-junction method is useful for the analysis of water hammer phenomena and of the blowdown thrust force. (2) The Henry-Fauske model for subcooled critical flow is effective for the analysis of the maximum thrust force under the PWR LOCA conditions. The jet thrust parameter of analysis and experiment is 1.08. (3) The thrust parameter of saturated blowdown has the same ...

1982-09-01

117

Turbulent flow in a channel with transverse rib heat transfer augmentation  

Science.gov (United States)

Turbulent flow in a 2D channel with repeated rectangular rib roughness was numerically simulated using a low Reynolds number form of the k-epsilon turbulence model. Friction factors and average Stanton numbers were calculated for various pitch to rib height ratios and bulk Reynolds numbers. Comparisons with experiment were generally adequate, with the predictions of friction superior to those for heat transfer. The effect of variable properties for channel flow was investigated, and the results showed a greater effect for friction than for heat transfer. Comparison with experiment yielded no clear conclusions. The turbulence model was also validated for a related problem, that of flow downstream of an abrupt pipe expansion.

1993-04-01

118

Interfacial area transport: data and models  

International Nuclear Information System (INIS)

The objective of this research is to replace the current flow regime dependent interfacial area correlations in the thermal-hydraulic system analysis codes with an interfacial area transport equation, which dynamically models two-phase flow regime transitions. The interfacial area transport equation applicable to bubbly flows has been developed based on mechanistic modeling of bubble interaction. Detailed experiments have been performed for bubbly conditions in 2.54, 5.08 and 10.16-cm ID pipes to benchmark the model. This new approach predicts the continuous changes of the interfacial area and will eliminate artificial bifurcations stemming from the use of the static flow regime transition criteria. This paper presents the preliminary results of incorporating the one-group transport equation into the USNRC consolidated code, currently under development. The framework for the ...

2001-05-23

119

Plugging indicator for controlling the sodium quality. Indicateur de bouchage pour le controle de la qualite du sodium  

Energy Technology Data Exchange (ETDEWEB)

This device has and head-race pipe with an external part and a coaxial inner part. A measuring head is mounted movable between these 2 parts and has at least a thermocouple and a mobile grid for varying the section and the sodium flow to facilitate the impurities dissolution. This ensemble is completed by a longitudinal body containing the main parts of the indicator and surrounded by a thermal exchanger to cool the sodium.

1991-09-20

121

Large scale steam valve test: Performance testing of large butterfly valves and full scale high flowrate steam testing  

Energy Technology Data Exchange (ETDEWEB)

This report presents the results of the design testing of large (36-inch diameter) butterfly valves under high flow conditions. The two butterfly valves were pneumatically operated air-open, air-shut valves (termed valves 1 and 2). These butterfly valves were redesigned to improve their ability to function under high flow conditions. Concern was raised regarding the ability of the butterfly valves to function as required with high flow-induced torque imposed on the valve discs during high steam flow conditions. High flow testing was required to address the flow-induced torque concerns. The valve testing was done using a heavily instrumented piping system. This test program was called the Large Scale Steam Valve Test (LSSVT). The LSSVT program demonstrated that the redesigned valves operated satisfactorily under high flow ...

1995-05-01

122

Study of the action of a phosphonate additive on steel scale deposit and corrosion in the hydrodynamic conditions of a channel flow cell; Etude de l'action d'un additif phosphone sur l'entartrage et sur la corrosion de l'acier dans les conditions hydrodynamiques d'une cellule a canal  

Energy Technology Data Exchange (ETDEWEB)

In cooling systems, an improved control of scale deposit and corrosion processes is a major challenge and an realistic evaluation tool for water treatments is of the utmost economic importance. In this study, a channel flow cell was used to allow in-situ electrochemical measurements in well defined electrolyte tube flowing conditions. An expression of the mass transfer towards the electrode was established where the diffusion-limited current is a function of Re{sup 1/3} in the laminar regime and was verified experimentally using the redox couples Fe[CN]{sub 6}{sup 4-}/ Fe[CN]{sub 6}{sup 3-} and O{sub 2}/OH{sup -}. This hydrodynamically controlled experimental device was developed to investigate scale deposit processes and to evaluate scale inhibitor efficiency using a electrochemical quartz crystal microbalance. Experiments were performed on three different waters, at various flow rates and ...

2000-10-17

123

Surge-line thermal stratification: Displacements and fatigue damage computations  

Energy Technology Data Exchange (ETDEWEB)

Slow, unexpected displacements have been experienced in most pressurized water reactor (PWR) surge lines. Sometimes, these displacement lead to gap closure at the pipe whip restraints. These movements occur because of thermal stratification. This movement has the potential to increase stresses to valves, which may exceed the material yield stress. To understand this phenomenon, Framatome, Commissariat a l'Energie Atomique, and Electricite de France have undertaken large programs for the study of (1) thermal-hydraulic tests with a half-scale Plexiglas surge line, (2) thermal-hydraulic computations of permanent states and transients with a two-dimensional model, and (3) mechanical analysis of displacements and computation of fatigue damage due to stratification. This paper deals with the last subject. Avoiding stratification in piping by process modifications is difficult because of the high flow rate needed. ...

1989-01-01

124

Study of a loop heat pipe using neutron radiography.  

Science.gov (United States)

An explanation is given of what a loop heat pipe (LHP) is, and how it works. It is then shown that neutron imaging (both real time neutron radioscopy and single exposure neutron radiography) is an effective experimental tool for the study of LHPs. Specifically, neutron imaging has helped to identify and correct a cooling water distribution problem in the condenser, and has enabled visualization of two-phase flow (liquid and vapor) in various components of the LHP. In addition, partial wick dry-out, a phenomenon of great importance in the effective operation of LHPs, is potentially identifiable with neutron imaging. It is anticipated that neutron radioscopy and radiography will greatly contribute to our understanding of LHP operation, and will lead to improvement of LHP modeling and design. PMID:15246420

2004-10-01

125

Study of a loop heat pipe using neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

An explanation is given of what a loop heat pipe (LHP) is, and how it works. It is then shown that neutron imaging (both real time neutron radioscopy and single exposure neutron radiography) is an effective experimental tool for the study of LHPs. Specifically, neutron imaging has helped to identify and correct a cooling water distribution problem in the condenser, and has enabled visualization of two-phase flow (liquid and vapor) in various components of the LHP. In addition, partial wick dry-out, a phenomenon of great importance in the effective operation of LHPs, is potentially identifiable with neutron imaging. It is anticipated that neutron radioscopy and radiography will greatly contribute to our understanding of LHP operation, and will lead to improvement of LHP modeling and design.

2004-10-01

126

Study of a Loop Heat Pipe Using Neutron Radiography  

Energy Technology Data Exchange (ETDEWEB)

An explanation is given of what a loop heat pipe (LHP) is, and how it works. It is then shown that neutron imaging (both real time neutron radioscopy and single exposure neutron radiography) is an effective experimental tool for the study of LHPs. Specifically, neutron imaging has helped to identify and correct a cooling water distribution problem in the condenser, and has enabled visualization of two-phase flow (liquid and vapor) in various components of the LHP. In addition, partial wick dry-out, a phenomenon of great importance in the effective operation of LHPs, has been identified with neutron imaging. It is anticipated that neutron radioscopy and radiography will greatly contribute to our understanding of LHP operation, and will lead to improvement of LHP modeling and design.

2001-08-01

127

Determining effective soil formation thermal properties from field data using a parameter estimation technique  

Energy Technology Data Exchange (ETDEWEB)

A one-dimensional thermal model is derived to describe the temperature field around a vertical borehole heat exchanger (BHEx) for a geothermal heat pump. The inlet and outlet pipe flows are modeled as one, and an effective heat capacity is added to model the heat storage in the fluid and pipes. Parameter estimation techniques are then used to estimate various parameters associated with the model, including the thermal conductivity of the soil and of the grout which fills the borehole and surrounds the u-tube. The model is validated using test data from an experimental rig containing sand with known thermal conductivity. The estimates of the sand thermal conductivity derived from the model are found to be in good agreement with independent measurements.

1998-11-01

128

Determining Effective Soil Formation Thermal Properties From Field Data Using A Parameter Estimation Technique  

Energy Technology Data Exchange (ETDEWEB)

A one-dimensional thermal model is derived to describe the temperature field around a vertical borehole heat exchanger (BHEX) for a geothermal heat pump. The inlet and outlet pipe flows are modeled as one, and an effective heat capacity is added to model the heat storage in the fluid and pipes. Parameter estimation techniques are then used to estimate various parameters associated with the model, including the thermal conductivity of the soil and the grout that fills the borehole and surrounds the U-tube. The model is validated using test data from an experimental rig containing sand with known thermal conductivity. The estimates of the sand's thermal conductivity derived from the model are found to be in good agreement with independent measurements.

1999-01-01

129

Study on laminar burning velocity of premixed CH{sub 4}/O{sub 2}/CO{sub 2} flames; CH{sub 4}/O{sub 2}/CO{sub 2} yokongo kaen no soryu nensho sokudo ni kansuru kenkyu  

Energy Technology Data Exchange (ETDEWEB)

Experimental and numerical investigations were performed for the laminar burning velocity and the flame structure of laminar premixed CH{sub 4}/O{sub 2}/CO{sub 2} flames. Measurements of the laminar burning velocity were conducted by using a flame cone angle method for a circular nozzle burner. Numerical simulation was performed using one-dimensional plane flame code including radiation heat loss with an optically thin model. It was shown that the laminar burning velocity decrease with CO{sub 2} addition even though the adiabatic flame temperature is the same as that for CH{sub 4}/Air flames. The radiation heat loss is significant for the CH{sub 4}/O{sub 2}/CO{sub 2}, flames, and the flame temperature and laminar burning velocity decreases when the radiation heat loss is considered. Effects of thermal properties, radiation, and chemical reaction on the determination of the ...

1999-07-25

130

Interfacial area transport equation: model development and benchmark experiments  

Energy Technology Data Exchange (ETDEWEB)

The interfacial area transport equation dynamically models two-phase flow regime transitions and predicts continuous changes of the interfacial area concentration along the flow field. It replaces the flow regime-dependent correlations for the interfacial area concentration in thermal-hydraulic system analysis. In the present study, detailed formulation of the interfacial area transport equation is presented along with its evaluation results based on the detailed benchmark experiments. In view of model evaluation, the equation is simplified into one-dimensional steady state one-group interfacial area transport equation. The prediction made by model agrees well with the experimental data obtained in round pipes of various diameters. The framework for the two-group transport equation and the necessary constitutive relations are also presented in view of bubble transport of various sizes and shapes. ...

2002-07-01

131

Cooling device for impurity removal device in thermonuclear devices  

International Nuclear Information System (INIS)

Purpose: To prevent structure material meltdown upon rupture of cooling pipeways in a impurity remover by preventing the coolants from flowing into the vacuum vessel while continuing the supply of coolants to other portions to be cooled. Constitution: Dual cooling pipeway systems are disposed to the neutralizing plates of the impurity remover. A rupture detector (pressure gage) is mounted to each of the cooling pipeways and flow rate control valves to be opened and closed by the signal from the detector are disposed to the upstream and downstream of the cooling pipeway. In this constitution if the cooling pipes should be ruptured, the coolant supply is stopped to the ruptured system in which the flow rate valve is closed by the signal from the rupture detector. However, since the coolant is kept to be supplied to the other system of the cooling pipeways, meltdown of the neutralizing plates can be ...

1983-08-26

132

Examination of scaling criteria for nuclear reactor thermal-hydraulic test facilities  

International Nuclear Information System (INIS)

Scaling criteria for a natural-circulation loop are examined. The present state of knowledge of scaling to obtain similarity during single- and two-phase flow conditions in a closed loop are reviewed, and an alternative development of two-phase similarity parameters is presented. The loop scaling criteria are the results of analyses in which flow from one component to another is considered. In this work, boundary conditions for the closed loop are developed to obtain scaling criteria for leak flow, injection flow, and heat loss to ambient. The leak scaling criteria are specialized for modeling approaches using prototypic fluid at prototypic or reduced pressures. The derived scaling parameters are examined for their application to two existing scaled test facilities: the Multi-Loop Integral System Test (MIST) facility at Babcock and Wilcox, and the UMCP 2 x 4 facility at the University of Maryland ...

1987-01-01

133

Atomization and deposition rates in vertical annular two-phase flow  

Energy Technology Data Exchange (ETDEWEB)

The two-phase annular regime is characterized by a high velocity gas stream flowing through the core of the tube surrounded by a thin, highly agitated liquid film flowing concurrently along the tube wall. Part of the liquid may be entrained as droplets in the gas phase. The specific goals of this study were to measure fully developed rates of interchange and entrained fraction over a wide range of flow variables in the upward configuration of the annular regime, to obtain a more fundamental understanding of liquid interchange phenomena via studies of liquid film characteristics and to develop an improved design correlation for the entrained fraction. Towards this end, air-water experiments were conducted in two vertical pipe lines, 2.54 and 4.20 cm in diameter. Air velocities ranging from 20 to 120 m/s and total liquid flow rates ranging from 10 to 100 g/s were investigated. Two ...

1988-01-01

134

Application of hydraulic network analysis to motor operated butterfly valves in nuclear power plants  

International Nuclear Information System (INIS)

This paper presents the application of hydraulic network analysis to evaluate the performance of butterfly valves in nuclear power plant applications. Required actuation torque for butterfly valves in high-flow applications is often dictated by peak dynamic torque. The peak dynamic torque, which occurs at some intermediate disc position, requires accurate evaluation of valve flow rate and pressure drop throughout the valve stroke. Valve flow rate and pressure drop are significantly affected by the valve flow characteristics and the hydraulic system characteristics, such as pumping capability, piping resistances, single and parallel flow paths, system hydrostatic pressure, and the location of the motor-operated valve (MOV) within the system. A hydraulic network analysis methodology that addresses the effect of these parameters on the MOV performance is presented. ...

1992-07-01

135

An objective indicator for two-phase flow pattern transition  

Energy Technology Data Exchange (ETDEWEB)

This work concerns the development of a methodology the objective of which is to characterize and diagnose two-phase flow regime transitions. The approach is based on the fundamental assumption that a transition flow is less stationary than a flow with an established regime. During the first time, the efforts focused on: (1) the design and construction of an experimental loop, allowing to reproduce the main horizontal two-phase flow patterns, in a stable and controlled way; (2) the design and construction of an electrical impedance probe, providing an imaged information of the spatial phase distribution in the pipe; and (3) the systematic study of the joint time-frequency and time-scale analysis methods, which permitted to define an adequate parameter quantifying the unstationarity degree. During the second time, in order to verify the fundamental assumption, a series of experiments ...

1998-08-01

136

An objective indicator for two-phase flow pattern transition  

International Nuclear Information System (INIS)

This work concerns the development of a methodology the objective of which is to characterize and diagnose two-phase flow regime transitions. The approach is based on the fundamental assumption that a transition flow is less stationary than a flow with an established regime. During the first time, the efforts focused on: (1) the design and construction of an experimental loop, allowing to reproduce the main horizontal two-phase flow patterns, in a stable and controlled way; (2) the design and construction of an electrical impedance probe, providing an imaged information of the spatial phase distribution in the pipe; and (3) the systematic study of the joint time-frequency and time-scale analysis methods, which permitted to define an adequate parameter quantifying the unstationarity degree. During the second time, in order to verify the fundamental assumption, a series of experiments ...

1998-08-01

137

Vorticity-velocity method for the Graetz problem and the effect of natural convection in a horizontal rectangular channel with uniform wall heat flux  

Energy Technology Data Exchange (ETDEWEB)

Numerical solutions given by a vorticity-velocity method are presented for combined free and forced laminar convection in the thermal entrance region of a horizontal rectangular channel without the assumptions of large Prandtl number and small Grashof number. The channel wall is heated with a uniform wall heat flux. Typical developments of temperature profile, secondary flow, and axial velocity at various axial positions in the entrance region are presented. Local friction factor and Nusselt number variations are shown for Rayleigh numbers Ra = 10{sup 4}, 3 {times} 10{sup 4}, 6 {times} 10{sup 4}, and 10{sup 5} with the Prandtl number as a parameter. The solution for the limiting case of large Prandtl number and small Grashof number obtained from the present study confirms the data of existing literature. It is observed that the large Prandtl number assumption is valid for Pr = 10 when Ra {le} 3 {times} 10{sup 4} but for a larger Prandtl number ...

1987-08-01

138

Heat transfer augmentation due to surface radiative exchange effect of internal fins in an annulus  

International Nuclear Information System (INIS)

Heat transfer augmentation due to surface radiation in an annulus with fins was investigated both theoretically and experimentally for fully developed laminar flow. The system considered in the present study was an array of axially internal and straight fins attached to the outer tube wall. Analytical solutions were given for 4, 8, 16, 24, 32 fins and for the ratios of the fin height to the passage clearance, 0, 0.2, 0.4, 0.5, 0.6, 0.8. The experiments were performed with air as the working fluid for radius ratio of 1.45, 16 fins and for Reynolds numbers ranging from 500 to 2000. The numerically predicted results of the convective/radiative heat transfer for the present case were in good agreement with the experimental data. It was found that the heat transfer augmentation coefficient attained a maximum value of 1.45 for 32 fins and for a dimensionless fin height of 0.65.

1987-08-01

139

Empirically derived predicators of natural gas flame lengths in circular tubes  

Energy Technology Data Exchange (ETDEWEB)

Flame lengths inside circular tubes, using an (in-shot) atmospheric burner design commonly found in gas-fired residential furnaces were visually observed for natural gas and air under various operating conditions. The flame length data were reduced into dimensionless flame lengths, which were shown to be linearly proportional to the Peclet number of the fuel and air mixture. The dimensionless flame length dependence reported does not scale according to the classical flame models: pre-mixed (laminar) flame or diffusion flame. Instead, the flame length dependence was found to scale with the fuel burn speed, gas/mixture properties (evaluated at the adiabatic flame temperature), and flow parameters. Currently, this is the only flame length study available for the standard atmospheric burner designs commonly used in residential heating products. The results and data reduction provide an easy method to compute flame length penetrations inside ...

2000-07-01

140

Detailed chemical kinetic reaction mechanism for oxidation of n-octane and iso-octane  

Energy Technology Data Exchange (ETDEWEB)

The development of detailed chemical kinetic reaction mechanisms for oxidation of n-octane and iso-octane is described, with emphasis on the factors which are specific to many large hydrocarbon fuel molecules. Elements which are of particular importance are found to include site-specific abstraction of H atoms, radical isomerization of alkyl radicals by internal H atom abstraction, and rapid ..beta..-scission of the alkyl radicals. These features, combined with distinctions in the types of intermediate olefin species produced, are used to explain the significant differences in the rate of oxidation between n-octane and iso-octane. Experimental results from the turbulent flow reactor and low pressure laminar flames, using both n-octane and iso-octane as fuels, are used to test the reaction mechanisms and indicate those parts of the total mechanisms which are in greatest need of further development and refinement. It is found that the ...

1986-04-15

141

A proposed methodology for computational fluid dynamics code verification, calibration, and validation  

Energy Technology Data Exchange (ETDEWEB)

Verification, calibration, and validation (VCV) of Computational Fluid Dynamics (CFD) codes is an essential element of the code development process. The exact manner in which code VCV activities are planned and conducted, however, is critically important. It is suggested that the way in which code validation, in particular, is often conducted--by comparison to published experimental data obtained for other purposes--is in general difficult and unsatisfactory, and that a different approach is required. This paper describes a proposed methodology for CFD code VCV that meets the technical requirements and is philosophically consistent with code development needs. The proposed methodology stresses teamwork and cooperation between code developers and experimentalists throughout the VCV process, and takes advantage of certain synergisms between CFD and experiment. A novel approach to uncertainty analysis is described which can both distinguish between and quantify various types of ...

1995-07-01

142

Condensation driven water hammer studies for feed water distribution pipe  

International Nuclear Information System (INIS)

Special T-shaped feedwater distribution pipes were installed in steam generators at the Loviisa (Finland) and Rovno (Russia) nuclear power plants. The new shape was tested in an extensive testing programme. Since the tubes frequently suffer from corrosion damage, large-scale water hammer experiments were performed on a model facility in 1996. The main objectives of the water hammer experiments were to find out the prevailing parameters leading to water hammers, as well as the sensitivity of hammering to boundary conditions. A water hammer may occur when the mass flow rate into the steam generator exceeds 6 kg/s and the temperature difference between steam generator and feedwater exceeds 100 degC. Visual experiments and stress analyses of the pipe were also carried out. The weakest part, the T-joint, may hold against such water hammers only for a limited time of the order of few minutes. (M.D.).

1997-05-26

143

Study on the transient piping vibration of power plant. Secondary piping system of Wolsung 1 unit.  

Science.gov (United States)

In order to maintain a safe operation and availability of generating facilities, qualitative and quantitative assessment of piping vibration was performed vibration sources and damages of piping support was identified on the second piping system of Wolsun...

1996-01-01

144

An investigation of Newton-Krylov algorithms for solving incompressible and low Mach number compressible fluid flow and heat transfer problems using finite volume discretization  

Energy Technology Data Exchange (ETDEWEB)

Fully coupled, Newton-Krylov algorithms are investigated for solving strongly coupled, nonlinear systems of partial differential equations arising in the field of computational fluid dynamics. Primitive variable forms of the steady incompressible and compressible Navier-Stokes and energy equations that describe the flow of a laminar Newtonian fluid in two-dimensions are specifically considered. Numerical solutions are obtained by first integrating over discrete finite volumes that compose the computational mesh. The resulting system of nonlinear algebraic equations are linearized using Newton`s method. Preconditioned Krylov subspace based iterative algorithms then solve these linear systems on each Newton iteration. Selected Krylov algorithms include the Arnoldi-based Generalized Minimal RESidual (GMRES) algorithm, and the Lanczos-based Conjugate Gradients Squared (CGS), Bi-CGSTAB, and Transpose-Free Quasi-Minimal Residual (TFQMR) algorithms. ...

1995-10-01

145

Simulation experiments for hot-leg U-bend two-phase flow phenomena  

International Nuclear Information System (INIS)

In order to study the two-phase natural circulation and flow termination during a small break loss of coolant accident in LWR, simulation experiments have been performed. Based on the two-phase flow scaling criteria developed under this program, an adiabatic hot leg U-bend simulation loop using nitrogen gas and water and a Freon 113 boiling and condensation loop were built. The nitrogen-water system has been used to isolate key hydrodynamic phenomena from heat transfer problems, whereas the Freon loop has been used to study the effect of phase changes and fluid properties. Various tests were carried out to establish the basic mechanism of the flow termination and reestablishment as well as to obtain essential information on scale effects of parameters such as the loop frictional resistance, thermal center, U-bend curvature and inlet geometry. In addition to the above experimental study, a preliminary modeling study has been ...

1986-10-27

146

Simulation experiments for hot-leg U-bend two-phase flow phenomena  

Energy Technology Data Exchange (ETDEWEB)

In order to study the two-phase natural circulation and flow termination during a small break loss of coolant accident in LWR, simulation experiments have been performed. Based on the two-phase flow scaling criteria developed under this program, an adiabatic hot leg U-bend simulation loop using nitrogen gas and water and a Freon 113 boiling and condensation loop were built. The nitrogen-water system has been used to isolate key hydrodynamic phenomena from heat transfer problems, whereas the Freon loop has been used to study the effect of phase changes and fluid properties. Various tests were carried out to establish the basic mechanism of the flow termination and reestablishment as well as to obtain essential information on scale effects of parameters such as the loop frictional resistance, thermal center, U-bend curvature and inlet geometry. In addition to the above experimental study, a preliminary modeling study has been ...

1986-01-01

147

Sensitivity Study for CFD Analysis on Debris Transport to ECCS Sump for CANDU Type Plant in Korea  

International Nuclear Information System (INIS)

Once containment recirculation pumps are activated and emergency core cooling (ECC) flow is supplied from the recirculation sump during loss of coolant accident (LOCA), various insulations and coatings on a pipe, equipments and structures damaged by LOCA break jet as well as additional debris sources are transported to recirculation sump screen by the break flow and containment spray flow drainage. This debris may result in loss of net pressure suction head (NPSH) of the recirculation pumps, and have a threat to long term cooling and containment heat removal capacity. In this case, flow patterns of containment pool are important to confirm behaviors of debris transport for predicting various flow paths to the recirculation sump screen. In this paper, models using commercial computational fluid dynamics (CFD) software CFX are developed for containment pool ...

2010-10-01

148

Dynamic modeling of interfacial structures via interfacial area transport equation  

International Nuclear Information System (INIS)

The interfacial area transport equation dynamically models the two-phase flow regime transitions and predicts continuous change of the interfacial area concentration along the flow field. Hence, when employed in the numerical thermal-hydraulic system analysis codes, it eliminates artificial bifurcations stemming from the use of the static flow regime transition criteria. Accounting for the substantial differences in the transport phenomena of various sizes of bubbles, the two-group interfacial area transport equations have been developed. The group 1 equation describes the transport of small-dispersed bubbles that are either distorted or spherical in shapes, and the group 2 equation describes the transport of large cap, slug or churn-turbulent bubbles. The source and sink terms in the right-hand-side of the transport equations have been established by mechanistically modeling the creation and destruction of bubbles due to ...

2005-01-01

149

Field-controllable electro- and magneto-rheological fluid dampers in flow mode using Herschel-Bulkley theory  

Science.gov (United States)

The Bingham plastic constitutive model has been widely used to predict the post-yield behavior of electro- and magneto- rheological fluids (ER and MR fluids). However, if these fluids experience shear thinning or shear thickening, the Bingham plastic model may not be an accurate predictor of behavior, since the post-yield plastic viscosity is assumed to be constant. In a recent study, it was theoretically and experimentally demonstrated that the Herschel-Bulkley fluid model can be successfully employed when evaluating non- Newtonian post-yield behavior of ER and MR fluids. In this paper, the Herschel-Bulkley model is employed to include a detailed analysis of ER and MR fluid dynamics through pipes and parallel plates. Simplified explicit expressions for the exact formulation are also developed. It is shown that the proposed simplified model of the Herschel-Bulkley steady flow equations for pipes and parallel plates can be ...

2000-04-01

150

Removal of uranium by biosorption  

Energy Technology Data Exchange (ETDEWEB)

The technology developed here will exploit the ability of microorganisms to remove dissolved metals from aqueous solutions. Microbial sorbents for uranium will be immobilized biosorbents will be deployed ex situ within flow-through reactors for the continuous or semicontinuous treatment of recovered wastewaters. The proposed technology will primarily be applied within a pump-and-treat process using immobilized biosorbents for the large-scale, long-term remediation of uranium-laden surface water or groundwater impoundments (environmental restoration). The technology may be equally useful as an ``end-of-pipe`` treatment of process effluents (waste management). Successful operation of this process will achieve immobilization of the targeted waste and accompanying volume reduction.

1993-06-01

151

Modeling of feed water check valves using RELAP5; Modellierung von Speisewasserrueckschlagventilen in RELAP5  

Energy Technology Data Exchange (ETDEWEB)

Westinghouse Electric Germany GmbH has developed fluid dynamic models for medium-actuated armatures using the thermal hydraulic code RELAP5 in order to reach a more realistic description of the armature behavior including fluid-structure interactions in case of transient flow conditions in piping systems. The contribution is concerned with the modeling of damped check valves. The model allows the description of the behavior during opening and closure of a check armature. The calculated results show good agreement with the available measured data.

2009-07-01

152

Dalia integrated production bundle (IPB): an innovative riser solution for deep water fields  

Energy Technology Data Exchange (ETDEWEB)

The Dalia field is located 210 km north west of Luanda (Angola), about 140 km from shore in 1400 meter water-depth. It was the second major discovery out of 15 made in the block 17 operated by Total. The Dalia Umbilical, Flow lines and Risers EPCI Contract was awarded in 2003. The sea-line network to connect and control the 71 wells and 9 manifolds consist of the following: 40 km of insulated pipe in pipe (12 inches into 17 inches) production flow lines; 45 km of 12 inches water and gas injection lines; 6 off 1.7 km flexible water and gas injection risers; 8 off 1.65 km flexible Integrated Production Bundle (IPB) risers; 75 km of control umbilicals. The flow assurance and associated insulation requirement of the production transport system was one of the main challenges of the project. With a crude temperature of 45 deg C at the wellhead and the required minimum temperature of 35 ...

2008-07-01

153

Chemical reactions in a solar furnace 2: Direct heating of a vertical reactor in an insulated receiver. Experiments and computer simulations  

Energy Technology Data Exchange (ETDEWEB)

The performance of a solar chemical heat pipe was studied using CO{sub 2}reforming of methane as the endothermic reaction. A directly heated vertical reactor, packed with a rhodium catalyst was used. The solar tests were carried out in the Schaeffer solar furnace of the Weizmann Institute of Science. The power absorbed was up to 6.3 KW, the maximal flow rates of the gases reached 11,000 1/h, and the methane conversions reached 85%. A computer model was developed to simulate the process. Agreement of the calculations with the experimental results was quite satisfactory.

1992-01-01

154

Two-phase flow patterns and frictional pressure gradients in a small, horizontal, rectangular channel  

Energy Technology Data Exchange (ETDEWEB)

Two-phase flow patterns and frictional pressure gradients in flow in small, rectangular channels are being studies as part of a larger research program addressing phase-change heat transfer of pure refrigerants and refrigerant mixtures in plate-fin heat exchangers. Small rectangular flow channels were selected as representative of plain fin geometries. The particular channel reported herein has dimensions of 19.05 {times} 3.18 mm. Adiabatic flows of air/water mixtures, with the flow channel horizontal and the channel exit at near-atmospheric conditions, were utilized in the experiments. Analysis and interpretation of the pressure data relative to observed flow pattern transitions led to an objective method for determining the plug/bubble-to-slug flow transition. This method, together with visual observations, supplemented with photographic ...

1990-05-01

155

Pipe crawlers  

International Nuclear Information System (INIS)

The patent concerns pipe crawlers, i.e. apparatus capable of moving along the bores of pipes and tubes. Pipe crawlers are employed for conveying inspection equipment along the bores of pipes and tubes. The pipe crawler comprises a piston and assembly system, which controls the movement of the crawler and supports the assembly centrally within the bore of the pipe or tube. (UK).

1984-11-29

156

Characterization of flame front surfaces in turbulent premixed methane/air combustion  

Energy Technology Data Exchange (ETDEWEB)

A detailed experimental investigation of the application of fractal geometry concepts in determining the turbulent burning velocity in the wrinkled flame regime of turbulent premixed combustion was conducted. The fractal dimension and cutoff scales were determined for six different turbulent flames in the wrinkled flame regime, where the turbulence intensity, turbulent length scale, and equivalence ratio were varied. Unlike previous reports, it has proved possible to obtain the fractal dimension and inner and outer cutoffs from individual flame images. From this individual data, the pdf distributions of all three fractal parameters, along with the distribution of the predicted increase in surface area, may be determined. The analysis of over 300 flame images for each flame condition provided a sufficient sample size to accurately define the pdf distributions and their means. However, the predicted S{sub T}/S{sub L}, calculated using fractal parameters, was significantly below the ...

1995-06-01

157

Airway problems in children--can the orthodontist help?  

Science.gov (United States)

The adequacy of the nasopharyngeal airway has been found to be related to craniofacial development. Obstruction of the airway by adenoid tissue, nasal septal deviation or abnormal morphology of the area is associated with characteristic changes in craniofacial morphology such as long anterior face height, facial retrognathism, and a steep inclination of mandibular plane often with a high vaulted palate and crossbite. Some studies have shown the changes to be reversible after adenoidectomy which improves nasal airway patency and a control mechanism for facial growth has been proposed to account for the relationships between airway adequacy, craniofacial morphology and craniocervical postural relationships. It is therefore important to be able to measure nasal respiratory resistance so that the effect of operative procedures in the area such as rapid maxillary expansion (RME) can be determined. Nasal respiratory resistance (NRR) is a measure of airway adequacy. It can be recorded by ...

1995-01-01

158

Pipe whip: a summary of the damage observed in BNL pipe-on-pipe impact tests  

Energy Technology Data Exchange (ETDEWEB)

This paper describes examples of the damage resulting from the impact of a whipping pipe on a nearby pressurised pipe. The work is a by-product of a study of the motion of a whipping pipe. The tests were conducted with small-diameter pipes mounted in rigid supports and hence the results are not directly applicable to large-scale plant applications where flexible support mountings are employed. The results illustrate the influence of whipping pipe energy, impact position and support type on the damage sustained by the target pipe.

1987-01-01

159

Pipe whip: a summary of the damage observed in BNL pipe-on-pipe impact tests  

International Nuclear Information System (INIS)

This paper describes examples of the damage resulting from the impact of a whipping pipe on a nearby pressurised pipe. The work is a by-product of a study of the motion of a whipping pipe. The tests were conducted with small-diameter pipes mounted in rigid supports and hence the results are not directly applicable to large-scale plant applications where flexible support mountings are employed. The results illustrate the influence of whipping pipe energy, impact position and support type on the damage sustained by the target pipe. (author).

160

Emergency core cooling system  

International Nuclear Information System (INIS)

Purpose: To obtain stabilized operation by preventing over heat in emergency cooling pumps upon accidents of flow regulators. Constitution: A pressure suppression chamber pool and a pressure vessel are communicated to each other with a pipeway and the water in the suppression pool is charged by a charging pump to the pipeway. The pipeway is interposed with an emergency cooling pump so as to feed water in the pipeway to the pressure vessel and a water source and the emergency cooling pumps are connected by way of a closed pipeway. Further, the closed pipeway and the pipeway interposed with the charging pump are communicated to each other by way of a connecting pipeway, to which are interposed an instrument for detecting the increase in the temperature of the emergency cooling pumps due to abnormality in the closed pipe (such as troubles in flow regulators) and outputting control signals and an electrically actuated valve ...

161

Bioreactors  

Energy Technology Data Exchange (ETDEWEB)

Composting is once again gaining interest among ecological engineers in view of greener industrial and residential activities. Uniform composting is needed to ensure decomposition and to keep the whole system at the same composting stage. A homogeneous temperature must be maintained throughout the media. A bioreactor design consisting of a heater core made of copper tubing was designed and tested. Two four-inch holes were made at the top and bottom of the barrel to allow air to flow through the system and promote aerobic composting. Once composting began and temperature increased, the water began to flow through the copper piping and the core heat was distributed throughout the medium. Three thermocouples were inserted at different heights on a 200 litre plastic barrel fitted with the aforementioned apparatus. Temperature variations were found to be considerably lower when the apparatus was operated with the heat ...

2010-07-01

162

Strain Rate Effects in SA-106 Carbon Steel Pipe,  

Science.gov (United States)

... rate on the tensile properties of SA-106 carbon steel pipe, in support of analysis and experimental modeling of postulated pipe whip in nuclear ...

1982-02-01

163

Parametric study of pipe whip behavior  

International Nuclear Information System (INIS)

A pipe whip test is one of the main subjects of the pipe rupture tests performed in Japan Atomic Energy Research Institute. In 1979, the pipe whip test of 4B, sch-80 pipe will be done under the BWR condition. As the preliminary analysis of this test, the pipe whip analysis of 4B, sch-80 pipe was implemented in order to make clear of the influences of the physical parameters on the pipe whip behavior. The pipe whip analysis was treated as nonlinear dynamic analysis of pipe-restraint system by using the general purpose finite element program ADINA. Overhang length, clearance between pipe and restraint, restraint length and cross section area of restraint were taken as physical parameters. It was clarified through this analysis how restraint displacement, restraint strain and ...

164

Experimental study on the air/water counter-current flow limitation in a model of the hot leg of a pressurized water reactor  

Energy Technology Data Exchange (ETDEWEB)

An experimental investigation on the air/water counter-current two-phase flow in a horizontal rectangular channel connected to an inclined riser has been conducted. This test-section representing a model of the hot leg of a pressurized water reactor is mounted between two separators in a pressurized experimental vessel. The cross-section and length of the horizontal part of the test-section are (0.25 m x 0.05 m) and 2.59 m, respectively, whereas the inclination angle of the riser is 50 deg. The flow was captured by a high-speed camera in the bended region of the hot leg, delivering a detailed view of the stratified interface as well as of dispersed structures like bubbles and droplets. Countercurrent flow limitation (CCFL), or the onset of flooding, was found by analyzing the water levels measured in the separators. The counter-current flow limitation is defined as the maximum air mass ...

2008-12-15

165

A study of flow boiling phenomena using real time neutron radiography  

International Nuclear Information System (INIS)

The operation and safety of both fossil-fuel and nuclear power stations depend on adequate cooling of the thermal source involved. This is usually accomplished using liquid coolants that are forced through the high temperature regions by a pumping system; this fluid then transports the thermal energy to another section of the power station. However, fluids that undergo boiling during this process create vapor that can be detrimental, and influence safe operation of other system components. The behavior of this vapor, or void, as it is generated and transported through the system is critical in predicting the operational and safety performance. This study uses two advanced penetrating radiation techniques, Real Time Neutron Radiography (RTNR), and High Speed X-Ray Tomography (HS-XCT), to examine void generation and transport behavior in a flow boiling system. The geometries studied were tube side flow boiling in a cylindrical configuration, and ...

1346-01-01

166

Reliability analysis for stiff versus flexible piping  

Energy Technology Data Exchange (ETDEWEB)

The overall objective of this research project is to develop a technical basis for flexible piping designs which will improve piping reliability and minimize the use of pipe supports, snubbers, and pipe whip restraints. The current study was conducted to establish the necessary groundwork based on the piping reliability analysis. A confirmatory piping reliability assessment indicated that removing rigid supports and snubbers tends to either improve or affect very little the piping reliability. We then investigated a couple of changes to be implemented in Regulatory Guide (RG) 1.61 and RG 1.122 aimed at more flexible piping design. We concluded that these changes substantially reduce calculated piping responses and allows piping redesigns with significant reduction in number of ...

1985-11-01

168

PWR primary circuit piping installation of Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

The installation procedure, the fabrication, fitting up, positioning, adjustment and welding of piping, examinations, hydrostatics testing and insulation of piping for reactor primary circuit piping of Daya Bay Nuclear power Plant are briefly described.

169

Overview of reliability test program on primary coolant piping of light water reactors  

Energy Technology Data Exchange (ETDEWEB)

Upon request by the Science and Technology Agency of Japanese Government, the Japan Atomic Energy Research Institute has conducted Piping Reliability Test Program to demonstrate the safety and reliability of light water reactor primary pipings. In this report, the results of the program are summarized. In the test program, pipe fatigue tests, Leak-Before-Break (LBB) verification tests and pipe rupture tests were carried out to examine the integrity of pipings, to verify the LBB concept and to demonstrate the effectiveness of the protective measures against jet impingement and pipe whip under pipe rupture event, respectively. In the pipe fatigue tests, a procedure to predict the fatigue crack growth was developed and the integrity of piping during plant service life was demonstrated. In the LBB ...

1993-10-01

170

AIR BREATHING DEVICE FOR PIPE LINE  

J-STORE (Japan)

Full Text Available

2004-11-29

171

Technical considerations for flexible piping design in nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

The overall objective of this research project is to develop a technical basis for flexible piping designs which will improve piping reliability and minimize the use of pipe supports, snubbers, and pipe whip restraints. The current study was conducted to establish the necessary groundwork based on the piping reliability analysis. A confirmatory piping reliability assessment indicated that removing rigid supports and snubbers tends to either improve or affect very little the piping reliability. A couple of changes to be implemented in Regulatory Guide (RG) 1.61 and RG 1.122 aimed at more flexible piping design were investigated. It was concluded that these changes substantially reduce calculated piping responses and allows piping redesigns with significant reduction in number of ...

1985-03-15

172

Numerical study of natural convection in fully open tilted cavities  

Energy Technology Data Exchange (ETDEWEB)

A numerical simulation of two-dimensional laminar natural convection in a fully open tilted square cavity with an isothermally heated back wall is conducted. The remaining two walls of the cavity are adiabatic. Steady-state solutions are presented for Grashof numbers between 10{sup 2} and 10{sup 5} and for tilt angles ranging from {minus}60{degree} to 90{degree} (where 90{degree} represents a cavity with the opening facing down). The fluid properties are assumed to be constant except for the density variation with temperature that gives rise to the buoyancy forces, which is treated by the Boussinesq approximation. The fluid concerned is air with Prandtl number fixed at 0.71. The governing equations are expressed in a normalized primitive variables formulation. Numerical predictions of the velocity and temperature fields are obtained using the finite-volume-based power law (SIMPLER: Semi-Implicit Method for Pressure-Linked Equations Revised) algorithm. For a ...

1999-09-01

173

Potential gas entry into FFTF after a postulated pipe rupture  

International Nuclear Information System (INIS)

... failures fftf reactor heat transfer hydraulics loss of coolant pipes primary coolant

174

Experimental and analytical studies of four-inch pipe whip tests under PWR LOCA conditions  

Energy Technology Data Exchange (ETDEWEB)

In the tests, the effects of the overhang length on the pipe whip behavior of the pipe-restraints system were studied by measuring the strains and deformations of the test pipe and restraints, and the restraints forces. The equation for predicting the maximum strain at the outer surface of the pipe was derived using a static equilibrium condition. The calculated maximum strains at the outer surface of the pipe agree fairly well with experimental data. The dynamic response analysis of the pipe-restraints system was conducted by the finite element program ADINA. The applicability of the ADINA program to the pipe whip analysis is made clear through this analysis.

1984-01-01

175

A model for the calculation of vent clearing transients in pressure suppression systems  

International Nuclear Information System (INIS)

For the layout of a pressure suppression system of a light water cooled reactor (boiling water reactor) it is important to know the time dependent behavior of the vent clearing transient after a loss-of-coolant accident for two main reasons: time of the end of the vent clearing transient influences strongly the pressure and temperature maxima in the drywell and wetwell. Time-dependent behavior of the vent clearing transient influences pressure loads in the condensation pool of the wetwell and therefore pressure induced stresses to the structure. The time-dependent behavior of the water masses in the vent pipes and wetwell are described by the basic equations for a nonstationary incompressible friction flow: momentum equation, continuity equation and a correlation for the variation of the state of the gas volume in the wetwell above the water level. After many algebraic operations and integrations along the flow path, a ...

1975-09-01

176

Pipe whip experiments involving impacts between pipes  

International Nuclear Information System (INIS)

Dynamic pipe impact tests were performed in order to determine the impact conditions for which a 2 inch Schedule 80 carbon steel target pipe would not be broken if it were impacted during a pipe whip event created by a postulated break of an adjacent larger parallel pipe. Such pipe/pipe impact scenarios are of special interest for the feeder pipes of a CANDU reactor because the large number of closely spaced parallel feeder pipes that carry coolant between large primary system pipes and individual fuel channels in the reactor core makes it impractical to consider providing feeder pipe whip restraints. The testing which was performed involved simulating the behaviour of 3 inch and larger whipping pipes in order to study their impact with 2 inch target pipes ...

177

Pipe behaviour in bottom ash slurry systems  

Energy Technology Data Exchange (ETDEWEB)

This study presents the results of an 18-year long investigation of pipe deterioration in cyclone slag slurry transport. The goal was to study pipe behaviour in this extremely abrasive service and select an optimum piping material. Comparisons are given for high quality alloy cast steel pipes and pipes alined with cast basalt rings marketed under the name Abresist.

1982-09-01

178

Pipe behaviour in bottom ash slurry systems  

Energy Technology Data Exchange (ETDEWEB)

This study presents the results of an 18-year long investigation of pipe deterioration in cyclone slag slurry transport. The goal was to study pipe behaviour in this extremely abrasive service and select an optimum piping material. Comparisons are given for high quality alloy cast steel pipes and pipes lined with cast basalt rings marketed under the name Abresist. Based on the results, thoughts are offered on the broader meanings of certain findings.

1982-09-01

179

Method of controlling the coolant level in the cooling system of a nuclear power plant  

International Nuclear Information System (INIS)

Object: To prevent a sudden drop in the level of a coolant in a annular pipe encased within a downcomer pipe. Structure: The coolant levels in annular pipes encased within downcomer pipes are simultaneously measured by level gauges which generate signals representative of coolant levels. The signals are fed to a level control system which will actuate valves to regulate the cover gas pressure in order to average the level differences among the annular pipes in different downcomer pipes. (Kamimura, M.).

180

Device for the inspection of curved pipes in steam raising units  

Energy Technology Data Exchange (ETDEWEB)

The chain of eddy current probes and a film cassette probe, which responds to radiation from a radio-active source in one of the heat exchanger pipes is examined. The probes are moved by nylon pipes on both ends of the chain through the pipe to be examined. The nylon pipes are bent off load. In this way the probes on the chain will adjust near to the plane of bending of the pipes to be tested.

1980-01-03

181

Results of reliability test program on light water reactor piping  

Energy Technology Data Exchange (ETDEWEB)

The Japan Atomic Energy Research Institute has conducted a piping reliability test program to demonstrate the safety and reliability of light water reactor primary piping. In this program, pipe fatigue test, leak-before-break (LBB) verification test and pipe rupture test were carried out to examine the integrity of piping, to verify the LBB and to demonstrate the effectiveness of protective measures against jet impingement and pipe whip loads under a pipe rupture event.In the pipe fatigue test, a procedure to predict the fatigue crack growth was developed, and the integrity of piping during the plant service life was evaluated. In the LBB verification test, the pipe fracture test and the leak rate test were performed to verify the LBB in the primary piping.In ...

1994-12-01

182

A phenomenological model of the thermal hydraulics of convective boiling during the quenching of hot rod bundles  

International Nuclear Information System (INIS)

In this paper, a phenomenological model of the thermal hydraulics of convective boiling in the post-critical-heat-flux (post-CHF) regime is developed and discussed. The model was implemented in the TRAC-PF1/MOD2 computer code (an advanced best-estimate computer program written for the analysis of pressurized water reactor systems). The model was built around the determination of flow regimes downstream of the quench front. The regimes were determined from the flow-regime map suggested by Ishii and his coworkers. Heat transfer in the transition boiling region was formulated as a position-dependent model. The propagation of the CHF point was strongly dependent on the length of the transition boiling region. Wall-to-fluid film boiling heat transfer was considered to consist of two components: first, a wall-to-vapor convective heat-transfer portion and, second, a wall-to-liquid heat transfer representing near-wall effects. Each contribution was ...

1983-10-14

183

Transient analysis of blowdown thrust force under PWR LOCA  

Energy Technology Data Exchange (ETDEWEB)

The analytical results of blowdown characteristics and thrust forces were compared with the experiments, which were performed as pipe whip and jet discharge tests under the PWR LOCA conditions. The blowdown thrust forces were obtained by Navier-Stokes momentum equation for a single-phase, homogeneous and separated two-phase flow, assuming critical pressure at the exit if a critical flow condition was satisfied. The following results are obtained: (1) The node-junction method is useful for both the analyses of the blowdown thrust force and of the water hammer phenomena. (2) The Henry-Fauske model for subcooled critical flow is effective for the analysis of the maximum thrust force under the PWR LOCA conditions. The jet thrust parameter of the analysis and experiment is equal to 1.08. (3) The thrust parameter of saturated blowdown has the same one with the value under pressurized condition when the ...

1983-04-01

184

Low temperature humidification dehumidification desalination process  

Energy Technology Data Exchange (ETDEWEB)

The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling water. The water production is found to depend strongly on the hot water ...

2006-03-01

185

Low temperature humidification dehumidification desalination process  

International Nuclear Information System (INIS)

The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling water. The water production is found to depend strongly on the hot water ...

2006-03-01

186

Reliability analysis of stiff versus flexible piping. Final project report  

Energy Technology Data Exchange (ETDEWEB)

This research project is to develop a technical basis for flexible piping designs which will improve piping reliability and minimize the use of pipe supports, snubbers, and pipe whip restraints. This study indicated that piping design can be made more reliable by some reduction of rigid supports and/or snubbers. This study also confirmed that the malfunction of pipe whip restraints introduced higher thermal stresses and tended to reduce the overall piping reliability. Finally, our results indicated that supports in a flexible piping design may need to be reevaluated and that the elimination of pipe supports which are close to components should be done with care in order to minimize the impact on the component reliability.

1985-05-01

187

Design and operation of an apparatus for calorimetric emittance measurements of pipe surfaces  

Energy Technology Data Exchange (ETDEWEB)

A technique for the measurement of the total hemispherical emittance of pipe surfaces is described, and design and operational details are given. The technique is conceptually simple. A long test pipe (e.g., 3.4 m) is mounted concentrically inside a Pyrex glass pipe. The system is evacuated, and the test pipe is heated by means of an electrical resistance heater. Heat transfer from the test pipe to the enclosure is almost solely radiative, allowing an average emittance for the test pipe and the Pyrex pipe and the electrical power input to the heater. By varying the electrical power level, one can measure the test pipe emittance as a function of temperature. By using a simple correction to account for the finite length of the test pipe, one can calculate the results using the simple expression for ...

1981-10-01

188

Structural integrity of whipping pipes following a postulated circumferential break - a contribution to determining strain levels acceptable under faulted conditions  

Energy Technology Data Exchange (ETDEWEB)

It is postulated that a break of a thin-walled pipe does not cause a subsequent break in the pipe in the vicinity of a plastic hinge even when the wall is weakened by a 60 circumferential crack of a depth of 30% of the wall thickness on the tension side. This pipe behavior is the result of plastic buckling in the compression side and applies to pipes of diameter-to-thickness ratio larger than 20. For this type of pipe, the axial strains decrease with increasing diameter-to-thickness ratio in the tension side. As the pipe is only loaded in one direction, there is no cyclic behavior that can trigger a subsequent break. (orig.)

1993-10-01

189

Conceptual design of a low-temperature radiation-hard tracker detector  

CERN Document Server

Silicon sensors have about ten times improved radiation hardness around 130 K temperature, compared with the state-of-art sensors close to room temperature. This is based on the Lazarus effect studied by the RD39 Collaboration of CERN. Other benefits of low temperatures will also be discussed. We shall describe the conceptual design of low-mass detector modules cooled using two-phase flow of argon in miniature cooling pipes integrated in the module structure between the sensors and the readout hybrid circuit. The main engineering features of the cooling system and mechanical support structures are discussed, as well as the benefits arising from the operation of the tracker under cryogenic vacuum. 4 Refs.

2003-01-01

190

Analysis of deteriorating processes in primary circuit facilities and determination of their priorities and relevance to the lifetime of the main primary circuit components  

International Nuclear Information System (INIS)

The major degradation mechanisms acting during the aging of selected WWER-440/213 primary circuit facilities were assessed critically. The analysis gave evidence that such mechanisms include radiation and fatigue damage of the reactor pressure vessel (effect of the neutron flow, cyclic fatigue promoted by the corrosive medium, effect of thermal aging), corrosion-mechanical and thermo-mechanical (fatigue) damage of the steam generator (stress corrosion cracking, erosion corrosion, thermal aging, wear), thermal and dynamic aging of the pressurizer, and corrosion-mechanical damage of the primary circuit piping (thermal aging, corrosion). (J.B.). 5 tabs., 1 fig., 62 refs.

191

A universal nutrient application strategy for the bioremediation of oil-polluted beaches  

British Library Electronic Table of Contents (United Kingdom)

Biostimulation by nutrient application is a viable technology for restoring oil-contaminated beaches. Maximizing the nutrient residence time is key for achieving a rapid cost-effective cleanup. We considered the nutrient injection strategy through a perforated pipe at the high tide line and we simulated numerically beach hydraulics, which allowed us to estimate the optimal injection flow rate of nutrient solution. Our results indicate that the optimal application is one that starts following the falling high tide and lasts for half tidal cycle. The saturated wet-front of the nutrient solution on the beach surface would move seaward with the same speed of the falling tide keeping a constant distance with the tide line. The numerical results were generalized to beaches of wide ranges of hydr...

2007-01-01

192

Lauric and palmitic acids eutectic mixture as latent heat storage material for low temperature heating applications  

Energy Technology Data Exchange (ETDEWEB)

Palmitic acid (PA, 59.8 {sup o}C) and lauric acid (LA, 42.6 {sup o}C) are phase change materials (PCM) having quite high melting temperatures which can limit their use in low temperature solar applications such as solar space heating and greenhouse heating. However, their melting temperatures can be tailored to appropriate value by preparing a eutectic mixture of the lauric and the palmitic acids. In the present study, the thermal analysis based on differential scanning calorimetry (DSC) technique shows that the mixture of 69.0 wt% LA and 31 wt% PA forms a eutectic mixture having melting temperature of 35.2 {sup o}C and the latent heat of fusion of 166.3 J g{sup -1}. This study also considers the experimental determination of the thermal characteristics of the eutectic mixture during the heat charging and discharging processes. Radial and axial temperature distribution, heat transfer coefficient between the heat transfer fluid (HTF) pipe and the PCM, heat recovery ...

2005-04-01

193

Piping response testing associated with pipe rupture  

Energy Technology Data Exchange (ETDEWEB)

EPRI has sponsored an experimental program in the pipe whip impact and pipe rupture and depressurization areas. Sixteen pipe whip tests were performed with 3 in Schedule 80 (or 10) carbon steel pipes impacting on rigid target or concrete slab. The major testing parameters include distance, impact location, pipe rupture location, and concrete slab thickness and strength. The piping crushing at impact correlates with impact force and target response behavior. Conservatism was established by comparing measured and calculated impact forces. The pipe rupture and depressurization tests were carried out using 6 in stainless steel and carbon steel pipes under either PWR or BWR fluid conditions. These tests are of axial crack with initial machined-in surface flaw. It was found that pipe rupture would occur ...

1985-11-01

194

Reliability analysis of stiff versus flexible piping. Status report  

Energy Technology Data Exchange (ETDEWEB)

Conservative design procedures adopted for nuclear piping systems usually result in stiff piping designs that use excessive support devices such as rigid supports and snubbers. Use of these piping support devices has created safety concerns. This report describes the interim result for a piping research project conducted at Lawrence Livermore National Laboratory (LLNL) for the US Nuclear Regulatory Commission (NRC). The overall objective of this research project is to develop modified design requirements and criteria which will improve piping reliability and minimize the use of pipe supports, snubbers, and pipe whip restraints. The current study was conducted to establish the necessary groundwork for this work based on the piping reliability analysis.

1984-04-01

195

Experimental and analytical studies of four-inch pipe whip tests under PWR LOCA conditions  

Energy Technology Data Exchange (ETDEWEB)

This paper presents experimental and analytical results of pipe whip tests performed under PWR LOCA conditions using a test pipe of 4-inch diameter and U-shaped restraints. In the tests, the effects of the overhang length on the pipe whip behavior of the piperestraints system were studied by measuring the strains and deformations of the test pipe and restraints, and the restraints forces. The equation for predicting the maximum strain at the outer surface of the pipe was derived using a static equilibrium condition. The calculated maximum strains at the outer surface of the pipe agree fairly well with experimental data. The dynamic response analysis of the pipe-restraints system was conducted by the finite element program ADINA. The applicability of the ADINA program to the pipe whip analysis is made clear through this ...

1984-01-01

196

Dynamic response analysis of pipe-restraints system. Analysis of pipe whip tests performed under PWR-LOCA conditions using 4-inch test pipe  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the results of the dynamic response analysis of the pipe-restraints system by the general purpose finite element program ADINA. The analysis was carried out for the pipe whip tests performed under the PWR-LOCA conditions using 4-in. test pipe. In the analysis, the test pipe was modeled by an assemblage of the beam elements with the isotropic elastic-plastic material properties and the restraints were represented by the truss elements with the nonlinear elastic material properties including gap effect. The following results are obtained through the analysis. (1) Pipe can be modeled with the beam elements, when the overhang length is short and, therefore, the flattening of a cross-section of pipe is small. (2) The steady state restraint force can be predicted by modeling the restraints with the truss elements.

1983-09-01

197

A study on the experimental verification for the pipe whip problem in a Nuclear Power Plant  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is to investigate on the experimental verification analysis for the pipe whip problems and to obtain the quantitative evaluation technologies for the design technique of pipe whip restraints. These will contribute to the advance of nuclear regulatory technologies and enhance nuclear power plant safety. This study presents the experimental and transient analytical results of pipe whip tests using the 4', 6' diameter pipe and U-shaped restraints. In the tests, the effects of the overhang length, clearance, impact height on the pipe whip behavior of the pipe-restraints were investigated. The transient impact analysis of the pipe-restraint system was conducted by the finite element program ABAQUS. The applicability of the ABAQUS program to the pipe whip analysis is made clear ...

1993-12-15

198

Demonstration of piping integrity with SMA technology  

Energy Technology Data Exchange (ETDEWEB)

The safe function of a new pipe whip restraint device has been demonstrated in a full scale test. The restraint is based on using a shape memory alloy to protect a pipe and its environment in the event of a double-ended-guillotine-break. The evaluation test has been performed at boiling water reactor (BWR) operating pressure and temperature using a pipe representing BWR primary piping. (orig.) 2 refs.

1997-10-01

199

Stromal-Derived Factor-1 (CXCL12) Regulates Laminar Position of Cajal-Retzius Cells in Normal and Dysplastic Brains  

UK PubMed Central (United Kingdom)

Normal brain development requires a series of highly complex and interrelated steps. This process presents many opportunities for errors to occur, which could result in developmental defects...Full Text Available

2006-09-13

200

Four loss-of-flow accidents in the SEAFP first wall/blanket cooling system  

Energy Technology Data Exchange (ETDEWEB)

This report presents the thermal-hydraulic analysis of four Loss-of-Flow Accidents (LOFAs) in the first wall/blanket cooling system of the alternative SEAFP reactor design. The LOFAs considered result from a loss of electrical power for the recirculation pump in the primary cooling circuit. The analyses have been performed using the thermal-hydraulic system analysis code RELAP5/MOD3. In the analyses, special attention has been paid to the transient thermal-hydraulic behaviour of the cooling system and the temperature development in the first wall and blanket. For the LOFA without plasma shutdown, significant loss of heat removal due to dryout occurs at the midplane of the outboard first wall cooling pipes about 41 s after pump trip. For the three LOFA cases with emergency plasma shutdown that have been studied, the temperature increase in the Be-coating at the midplane of the outboard first wall is limited to about 30 K. (orig.).

1994-07-01

201

An analysis of thinning status for CANDU feeder pipes  

Energy Technology Data Exchange (ETDEWEB)

The degradation status of outlet feeders in Wolsung unit 1 is analyzed using feeder thickness measurement data during overhaul period in 2000. DBs related to feeder thinning are made for parameters affecting dissolution rate and parameters affecting mass transfer rate. The initial thickness of feeder in Wolsung unit 1 is analyzed using initial thickness data of Wolsung unit 2, 3 and 4 as there are no initial thickness data of Wolsung unit 1. The initial thickness is varied as feeder diameter and bending degree, and CANDU feeders can be divided as 3 types for 2.5'' feeders and 3 types for 2'' feeders. The average initial thickness value for each type is defined as the initial thickness value of the type for Wolsung unit 1 feeders. Thinning rate is evaluated as the value dividing difference between initial thickness and minimum measured thickness by operation time. It is found that the distribution of thinning rate for flow ...

2000-10-01

202

Advanced solution algorithms for transient multidimensional thermohydraulic flow problems in complex geometries with the programme COMMIX-2/KfK  

Energy Technology Data Exchange (ETDEWEB)

The computer programme COMMIX-2 describes steady state and transient multidimensional single- and two-phase fluid flows with heat transfer in nuclear reactor components and multicomponent systems. Originally from the Argonne National Laboratory, the code has been further developed at the Kernforschungszentrum Karlsruhe. The original Point-SOR iterative method for the solution of a Poisson-like equation describing the pressure distribution in the fluid as well as the transport of enthalpy and turbulent quantities has been complemented with iterative and direct line- and block-methods. None of the newly implemented methods is original in itself but their implementation into the computer code, which can describe the most general shapes of definition domains, gave a code speed-up by a factor of 2-5, depending on the problem treated. The code capabilities are assessd by the calculation of a benchmark problem involving the numerical simulation of thermal buoyancy ...

1987-03-01

203

Advanced solution algorithms for transient multidimensional thermohydraulic flow problems in complex geometries with the programme COMMIX-2/KfK  

International Nuclear Information System (INIS)

The computer programme COMMIX-2 describes steady state and transient multidimensional single- and two-phase fluid flows with heat transfer in nuclear reactor components and multicomponent systems. Originally from the Argonne National Laboratory, the code has been further developed at the Kernforschungszentrum Karlsruhe. The original Point-SOR iterative method for the solution of a Poisson-like equation describing the pressure distribution in the fluid as well as the transport of enthalpy and turbulent quantities has been complemented with iterative and direct line- and block-methods. None of the newly implemented methods is original in itself but their implementation into the computer code, which can describe the most general shapes of definition domains, gave a code speed-up by a factor of 2-5, depending on the problem treated. The code capabilities are assessd by the calculation of a benchmark problem involving the numerical simulation of thermal buoyancy ...

1987-01-01

204

Dynamic modeling of interfacial structures via interfacial area transport equation; Modelisation dynamique des structures d'interface via l'equation de transport de l'interface  

Energy Technology Data Exchange (ETDEWEB)

The interfacial area transport equation dynamically models the two-phase flow regime transitions and predicts continuous change of the interfacial area concentration along the flow field. Hence, when employed in the numerical thermal-hydraulic system analysis codes, it eliminates artificial bifurcations stemming from the use of the static flow regime transition criteria. Accounting for the substantial differences in the transport phenomena of various sizes of bubbles, the two-group interfacial area transport equations have been developed. The group 1 equation describes the transport of small-dispersed bubbles that are either distorted or spherical in shapes, and the group 2 equation describes the transport of large cap, slug or churn-turbulent bubbles. The source and sink terms in the right-hand-side of the transport equations have been established by mechanistically modeling the creation and destruction of bubbles due to ...

2005-07-01

205

Structural analysis of piping after a large pipe break in a WWER-440 type reactor  

International Nuclear Information System (INIS)

In the WWER-440 reactor the primary piping consists of six horizontal loops going radially from the pressure vessel, each loop having a horizontal steam generator. In this reactor type the relatively long primary piping with many curved sections requires special attention in order to successfully eliminate the consequences of the design basis accident. Emergency supports are located in appropriate places to restrict the movements of the pipe in 1, 2, 3 or 4 directions depending on the geometry of the pipe near the support. Under normal conditions there is a gap of some centimeters between the pipe and a support so that the pipe can be deformed freely under changing loads. In order to analyse the behaviour of the broken piping system with the support structures a computer code called PIPEBREAK has been written. The main objects in the ...

1975-09-01

206

Performance of Buried Pipe Installations, Summary.  

Science.gov (United States)

The goal of this research project was to determine the eff ects of geometric and mechanical parameters characterizing the soil-structure interaction developed in a buried pipe installation. Parameters such as pipe ring stiff ness, bedding thickness, trenc...

2010-01-01

207

Method of pipe whip and impact analyses  

Energy Technology Data Exchange (ETDEWEB)

We successfully reproduce one of the French pipe whip experiments with the computer code WIPS. The WIPS results are in excellent agreement with the experimental data and the French computer code TEDEL. This justifies the use of its pipe element in conjunction with its U-bar element in a simplified method of impact analyses.

1983-11-21

208

Burner for rotary kiln; Braender til roteroven samt fremgangsmaade til dannelse af en braenderflamme med braenderen  

Energy Technology Data Exchange (ETDEWEB)

Burner for feeding a solid and a liquid or gaseous fuel to a kiln comprises a central supply pipe for liquid or gas surrounded concentrically by a first pipe providing an annular passage through which primary air is supplied. Concentrically surrounding that pipe is a second pipe providing an annular channel for supply of solid fuel in carrier air stream. The outlet end of the first concentric pipe is closed by a plate fixed mounted at the pipe end and providing multiple nozzles having their axes parallel to the burner axis. The surface of the plate facing the burning zone provides a divergence opening for the central pipe while the inner surface is formed with helical teeth. These are engaged by complementary teeth mounted on the end of the central pipe which is rotatable and biased by springs so that the teeth are in ...

1994-10-31

209

Thermal and heat transfer characteristics in a latent heat storage system using lauric acid  

Energy Technology Data Exchange (ETDEWEB)

The thermal and heat transfer characteristics of lauric acid during the melting and solidification processes were determined experimentally in a vertical double pipe energy storage system. In this study, three important subjects were addressed. The first one is temperature distributions and temporal temperature variations in the radial and axial distances in the phase change material (PCM) during phase change processes. The second one is the thermal characteristics of the lauric acid, which include total melting and total solidification times, the nature of heat transfer in melted and solidified PCM and the effect of Reynolds and Stefan numbers as inlet heat transfer fluid (HTF) conditions on the phase transition parameters. The final one is to calculate the heat transfer coefficient and the heat flow rate and also discuss the role of Reynolds and Stefan numbers on the heat transfer parameters. The experimental results proved that the PCM melts ...

2002-12-01

210

Safety design guide for pipe rupture protection for CANDU 9  

Energy Technology Data Exchange (ETDEWEB)

This safety design guide for pipe rupture protection identifies high-energy systems in which pipe ruptures must be postulated to occur, as well as systems that must be protected from the dynamic effects of such ruptures. Dynamic effects considered in this SDG consist of pipe whip (including missiles generated by pipe ruptures, if any) and jet impingement, Requirements for protection against the dynamic effects of a postulated pipe rupture and method of protection of essential structures, systems and components are specified for these effects. The change status for the regulatory requirements, code and standards should be traced and this safety design guide shall be updated accordingly. 2 tabs., 5 refs. (Author) .new.

1996-03-01

211

Nonlinear dynamic analysis of high energy line pipe whip  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a nonlinear dynamic analysis of TVA high energy line pipe whip tests using the ABAQUS-EPGEN code. The analysis considers the effects of large deformation and strain rate on resisting moment and energy absorption capability. The numerical results of impact forces, impact velocities, pipe strains, and reaction forces at pipe supports are compared to the TVA test data. The calculated pipe whip impact time and forces are also compared with those predicted using current industry practice. The calculated pipe support reaction forces are found to be in good agreement with the TVA test data except for some peak values at the very beginning of the pipe break. These peaks are believed to be due to stress wave propagation which cannot be addressed by the ABAQUS code. Both elbow crushing and strain rate have been approximately simulated. The effects are ...

1984-02-01

212

Multiple-Purpose Project, Little Blue River Basis East Fork ...  

Science.gov (United States)

... 146 27 1 Aug 83, outlet works excavation. Sewer pipe installation. ... No. 157. Outlet works excavation. Sewer pipe installation. ...

1990-09-01

213

Analytical studies of four-inch pipe whip tests under BWR LOCA conditions  

Energy Technology Data Exchange (ETDEWEB)

The purpose of pipe rupture studies in JAERI is to perform model tests on pipe whip, restraint behavior, jet impingement and jet thrust force, and to establish a computational method for analyzing these phenomena. This report presents the analytical results of 4-inch pipe whip tests under BWR LOCA conditions. Dynamic response analyses were performed using the general-purpose finite element program ADINA. The test pipe was modelled by straight beam elements and the four restraints were modelled by a single truss element. The analytical results were compared with the experimental results. Impact time and maximum total restraint force showed good agreement with experimental results. On the other hand, pipe strain and pipe deflection could not be predicted so well. The reason for this is that the sliding of the restraint during the pipe whip ...

1985-01-01

214

A study on the transient piping vibration of power plant. Secondary piping system of Wolsung 1 unit  

Energy Technology Data Exchange (ETDEWEB)

In order to maintain a safe operation and availability of generating facilities, qualitative and quantitative assessment of piping vibration was performed vibration sources and damages of piping support was identified on the second piping system of Wolsung nuclear power plant unit 1 .Inspected piping supports and structures in both hot and cold condition .Established evaluation procedures of piping vibration .Performed the static analysis of 2 nd piping system .Established optimal vibration reducing method .The measured vibration level after installing rigid supports and energy absorbing type restraint was reduced about 7 times in velocity unit (author). 24 refs., 95 figs.

1996-08-01

215

Verification of the CFD code FLUENT by post test calculation of ROCOM experiments  

International Nuclear Information System (INIS)

Full text of publication follows: The TUV NORD e.V. is an independent Technical Support Organisation (TSO) performing safety assessments in almost every field of technology. In nuclear safety the TUV can look back on more than 40 years of experience. In the last years in Germany PWR safety analyses were focussed on boron dilution events with the potential of reactivity transients. The possibility of coolant with a low boron concentration collected in localized areas of the reactor coolant system (RCS) can be caused by injection of coolant with less boron content from interfacing systems (external dilution) as well as separation of borated reactor coolant into highly concentrated and diluted fractions (inherent dilution). Inherent dilution can e.g. occur after reflux-condenser heat transfer after a small break loss of coolant accident (SBLOCA) with a limited operability of the emergency core cooling (ECC) systems. The TUV Nord e.V. was charged by German supervisory authorities with the ...

2005-10-02

216

Nonlinear dynamic analysis of high energy line pipe whip  

International Nuclear Information System (INIS)

To facilitate potential cost savings in pipe whip protection design, TVA conducted a 1'' high pressure line break test to investigate the pipe whip behavior. The test results are available to EPRI as a data base for a generic study on nonlinear dynamic behavior of piping systems and pipe whip phenomena. This paper describes a nonlinear dynamic analysis of the TVA high energy line tests using ABAQUS-EPGEN code. The analysis considers the effects of large deformation and high strain rate on resisting moment and energy absorption capability of the analyzed piping system. The numerical results of impact forces, impact velocities, and reaction forces at pipe supports are compared to the TVA test data. The pipe whip impact time and forces have also been calculated per the current NRC guidelines and compared. The calculated ...

217

Finite element analysis of pipe whip restraint behavior under jet thrust forces  

International Nuclear Information System (INIS)

Many types of pipe whip restraints are installed to protect the structural components from the anticipated pipe whip phenomena of high energy lines in nuclear power plants. It is necessary to investigate these phenomena accurately in order to design the pipe whip restraints properly and/or to evaluate the acceptability of the pipe whip restraint design. Various research programs have been conducted in many countries to develop analytical methods and to verify the validity of the methods. In this study, various types of finite elements in ANSYS, the general purpose finite element computer grogram, was used to simulate the postulated pipe whips to obtain impact loads and the calculted results were compared with the specific experimental results from the sample pipe whip test for the U-chaped pipe whip restraints. Some calculational models, ...

218

Experimental studies of pipe whip and impact: Final report  

Energy Technology Data Exchange (ETDEWEB)

An experimental and computational study was undertaken to estimate the effects of pipe rupture and induced pipe whip impact on surround structures considered either as rigid or deformative such as concrete slabs. This program included sixteen tests using 3 inch schedule 80 (or 10) pipes made of carbon steel similar to A106 grade B. The study consisted of tests on rigid target and on concrete slab. The investigation of whip phase and impact phase was done separately for each test. For pipe impact on rigid targets, the impact forces are found to be directly related to the crush strength of the pipe and the general pipe deformation following the impact. For pipe impact on concrete slabs, the response of the target to the pipe impact needs to take into account the local effect such as penetration and localized damage on the ...

1987-02-01

219

Experimental and analytical studies of 4-inch pipe whip tests under PWR LOCA conditions  

International Nuclear Information System (INIS)

The purposes of the pipe rupture studies at the Japan Atomic Energy Research Institute are to perform the model tests on the pipe whip of a pipe-restraints system, to get jet impingement force and blowdown thrust force, and to establish the computational method for the analysis of these phenomena. This paper presents the experimental and analytical results of the pipe whip tests carried out under the PWR LOCA conditions using the test pipe of 4-inch diameter and the U-shaped restraints. In the tests, the gap between the test pipe and the restraints was set nearly constant and the overhang length was 250 mm, 400 mm or 650 mm. The dynamic strains and residual deformations of the test pipe and restraints, and the restraint force were measured to clarify the effects of the overhang length on the pipe whip behaviors of the ...

220

Underground piping handbook  

Energy Technology Data Exchange (ETDEWEB)

This book provides the information required to design and prepare construction drawings, and to install, inspect, test, and commission buried piping. Both pressure and gravity piping are covered, including water, steam, gases, and sewers. Directed primarily toward underground industrial piping systems, this is a succinct, well-organized compilation of practical knowledge. Checklists, examples, tables, charts, nomographs, short cuts, and helpful hints gained through years of experience complete this timely and useful ''how to'' book.

1985-01-01

223

Experimental studies of 6-inch pipe whip tests under BWR LOCA conditions  

International Nuclear Information System (INIS)

Series of pipe rupture tests have been performed at the Japan Atomic Energy Research Institute to demonstrate the safety of the primary coolant circuits in the event of pipe rupture in nuclear power plants. The pipe whip tests have been conducted to study the dynamic response of the pipe and restraints. The results of the pipe whip tests using test pipes of 4-inch in diameter under the BWR LOCA conditions (285"0C, 6.8 MPa) were reported in the previous paper F8/5 of the 6th SMiRT. The present paper describes the results of the pipe whip tests using test pipes of 6-inch in diameter. The test pipe was made of Type 304 stainless steel and was 165.2 mm in outer diameter and 11.0 mm in thickness, and was fixed at the pipe support so that the length of the test section was 3000 mm. The ...

227

Dynamic modeling of interfacial structures via interfacial area transport equation  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows:In the current thermal-hydraulic system analysis codes using the two-fluid model, the empirical correlations that are based on the two-phase flow regimes and regime transition criteria are being employed as closure relations for the interfacial transfer terms. Due to its inherent shortcomings, however, such static correlations are inaccurate and present serious problems in the numerical analysis. In view of this, a new dynamic approach employing the interfacial area transport equation has been studied. The interfacial area transport equation dynamically models the two-phase flow regime transitions and predicts continuous change of the interfacial area concentration along the flow field. Hence, when employed in the thermal-hydraulic system analysis codes, it eliminates artificial bifurcations stemming from the use of the static flow regime transition criteria. Therefore, ...

2004-07-01

228

Pipework design and operation  

Energy Technology Data Exchange (ETDEWEB)

This book presents the proceedings of a conference dedicated to the design and operation of pipework in all its aspects, involving both metallic and non-metallic materials. Topics considered include a study of single mitre pipe bends using the finite element method; tests to failure of GRP pipe bends under in-plane flexural loading; finite element stress analysis of an equal diameter branch pipe intersection subjected to internal pressure and in-plane moment loadings; finite element stress analysis of extruded outlet tee junctions; design of pipework on the British PWR; a review of advanced remanent life methods for pipes operating in the creep range; pipe whip analysis and design; damping values for piping systems; pipework snubbers based on electro-rheological fluids; and the seismic design of piping systems in the flexible range.

1985-01-01

229

Experimental and analytical studies of pipe whip tests under PWR LOCA conditions  

Energy Technology Data Exchange (ETDEWEB)

A series of pipe rupture tests has been performed at JAERI to demonstrate the safety of primary coolant circuits in the event of pipe rupture in nuclear power plants. Pipe whip tests and jet discharge tests have been conducted under BWR and PWR loss-of-coolant accident (LOCA) conditions. The present paper describes the experimental and analytical results of the pipe whip tests performed under PWR LOCA conditions using 4, 6 and 8-inch test pipes. The tests were carried out at an initial pressure and temperature of 15.7 MPa and 325/sup 0/C, respectively. Moreover, a dynamic analysis of pipe whip tests was carried out using the general purpose finite element programm ADINA.

1987-09-01

230

Evaluation of pipe whip impacts on neighboring piping and walls of the Ignalina nuclear power plant.  

Energy Technology Data Exchange (ETDEWEB)

Presented in this paper is the transient analysis of a Group Distribution Header (GDH) following a guillotine break at the end of the header. The GDH is the most important component of reactor safety in case of accidents. Emergency Core Cooling System (ECCS) piping is connected to the GDH piping such that, during an accident, coolant passes from the GDH into the ECCS. The GDH that is propelled into motion after a guillotine break can impact neighboring GDH pipes or the nearest wall of the compartment. Therefore, two cases are investigated: GDH impact on an adjacent GDH and its attached piping; and GDH impact on an adjacent reinforced concrete wall. A whipping RBMK-1500 GDH along with neighboring concrete walls and pipelines is modeled using finite elements. The finite element code NEPTUNE used in this study enables a dynamic pipe whip structural analysis that accommodates large ...

2002-02-26

231

Comparative study of computational model for pipe whip analysis  

International Nuclear Information System (INIS)

Many types of pipe whip restraints are installed to protect the structural components from the anticipated pipe whip phenomena of high energy lines in nuclear power plants. It is necessary to investigate these phenomena accurately in order to evaluate the acceptability of the pipe whip restraint design. Various research programs have been conducted in many countries to develop analytical methods and to verify the validity of the methods. In this study, various calculational models in ANSYS code and in ADLPIPE code, the general purpose finite element computer programs, were used to simulate the postulated pipe whips to obtain impact loads and the calculated results were compared with the specific experimental results from the sample pipe whip test for the U-shaped pipe whip restraints. Some calculational models, having the spring element between the ...

1993-08-15

232

Study of the state of design for pipe whip. Final report. [PWR; BWR  

Energy Technology Data Exchange (ETDEWEB)

Design methods and parameters are described which are addressed when considering consequences of a postulated pipe rupture event in a nuclear plant design. Parameters discussed are break opening time and size, resultant blowdown characteristics of the effluent from the broken pipe, jet reaction and impingement loading, pipe motion, and pipe impact loading on steel and concrete structures. The impact the various parameters have on overall plant designs and conservatisms inherent in each consideration are evaluated in a qualitative nature. Finally, recommendations are provided for each parameter discussed for further evaluation and study.

1980-01-01

233

Emergency core cooling device for a reactor  

International Nuclear Information System (INIS)

Purpose : To obtain an emergency core cooling device in a FBR type reactor by utilizing heat pipes which are not actuated at usual operation condition but actuated reliably upon emergency. Constitution : A system for injecting heat medium into heat pipes is provided. By injecting the heat medium into the heat pipes upon emergency to actuate the heat pipes, the reactor core is cooled. During normal reactor operation, the inside of the heat pipes is evacuated from a vacuum pump and no heat medium is filled therein, whereby unnecessary heat loss during the normal operation can be prevented. (Ikeda, J.).

1982-01-24

234

Research on pipe whip and jet under LOCA conditions, (2)  

International Nuclear Information System (INIS)

The paper describes the experimental and analytical results of the pipe whip tests performed under the PWR LOCA conditions using 4, 6 and 8 inch test pipes. The tests were carried out at an initial pressure and a temperature of 15.7 MPa and 325 "0C. Two different types of tests were performed. One was the cantilever type pipe whip test using the test pipe of 3000 mm in length and U-shaped restraints. The other was the cross-over leg pipe whip test using a 1/6 model of piping in the PWR nuclear power plants. The cantilever type pipe whip tests were performed to investigate the influences of overhang length and pipe diameter on the pipe whip behavior. The movement of the test pipe is limited effectively by the restraints when the overhang length is short. The restraint force ...

235

Heat pipe cooled piston - feasibility study  

Energy Technology Data Exchange (ETDEWEB)

This study assesses the feasibility of the so-called heat pipe technique for cooling the piston of a mediumspeed diesel engine and is part of a research project 'EVE HPD, Extreme Value Engine Tests with High Power Density' carried out by HUT Internal Combustion Engine Laboratory. Diesel engines are being developed to give greater power from a given cylinder swept volume, which means higher temperatures in combustion chamber. The traditional oil cooling cannot be used beyond certain temperature level. Heat pipe technology could provide one solution to the cooling problem. The general properties, principles of operation, and structures of different types of heat pipes are described. Working fluids and container materials of heat pipes are discussed. The operation limitations of heat pipes are studied, especially, the limitations of a reciprocating heat ...

2004-07-01

236

Mitigating aging in CANDU plants  

Energy Technology Data Exchange (ETDEWEB)

Aging degradation is a phenomenon we all experience throughout life, both on a personal basis and in business. Many industries have been successful in postponing the inevitable impact on their related systems and components through programs to maintain long-term reliability, maintainability and safety. However, this has not always been the case for nuclear power. While all power plants are experiencing the world trend of increasing operating costs with age, few (if any) have been able to fully define the parameters that solve the aging equation, particularly in relation to major components. Inspection and preventive maintenance have not been effective in predicting life-limiting degradation and failure. In CANDU nuclear plants, utilities are taking a comprehensive approach in dealing with the aging problem. Programs have been established to identify the current condition and degradation mechanisms of critical components, the failure of which would impact negatively on station ...

1995-07-01

237

Sump Pool Flow Simulation during Fill-up Phase of LOCA Using on CFD for OPR1000 Plant  

Energy Technology Data Exchange (ETDEWEB)

During LOCA (Loss of Coolant Accident) in design bases accident (DBA), emergency core coolant supplements form a recirculation sump and cooled core and containment. When the double ended guillotine Break (DEGB) at the hot leg near steam generator, due to the jet impingement discharge flow, the debris could be potentially generated at pipe or wall nearby steam generator and be transported to the recirculation sump. Therefore, the debris, such as insulations and paint chips, could be accumulated and be clogged in the recirculation sump screen. If debris is blocked the sump strainer, the pressure drop is increased at the screen so as to increase the pressure loss of ECCS (Emergency Core Cooling System) pump NPSH (Net positive suction head). It is potentially influenced to decrease the long-term cooling capability of the recirculation sump. The recirculation sump screen clogging accident has happened in BWR of USA and Sweden. Considering the ...

2009-10-15

238

Scour and accretion in sub-sea structures  

Energy Technology Data Exchange (ETDEWEB)

Analytical means have been developed to predict scour and accretion in sub-sea structures. Such structures can be very large and can have a large density of piping and structural members. They introduce a blocking and a shielding in the flow at the sea bottom leading to variable velocities and turbulence in the interior of the structure. This changes the transport capacity of the flow and result in general erosion where the transport capacity is increased and in accretion where the transport capacity is decreased. In addition there may occur the so-called tunnel erosion for structures built on concrete mats or similar. This type of erosion undermines the foundation of the sub-sea structure. Analytical models are developed and programmed to analyse the above phenomena. The internal flow variations are found by means of the LICengineering shielding programme and these are coupled to the transport ...

1997-09-01

239

Three-dimensional mise-a-la-masse modeling using horizontal well; Suihei kosei wo mochiita ryuden den`iho no sanjigen modeling  

Energy Technology Data Exchange (ETDEWEB)

The 3-D model program was developed to apply a mise-a-la-masse method to linear current sources with optional shapes. Mise-a-la-masse method is a bipolar mapping survey method using current sources installed in wells, and recently has been widely used for direct exploration of geothermal reservoirs. This method is also used for monitoring underground fluid as electrode arrangement of fluid flow tomography for surveying underground fluid (geothermal fluid, underground water, petroleum). In the geothermal reservoir exploration, the casing pipes of wells are used as linear current sources, and measured data are processed as those based on vertical current source. In the largely inclined well, the inclination of current sources should be considered. The 3-D modeling program was developed by difference calculus using the theoretical potential equation and apparent resistivity based on linear current sources with optional 3-D shapes. The numerical ...

1996-10-01

240

The application of high pH operation to the secondary water chemistry at Genkai Nuclear Power Station  

International Nuclear Information System (INIS)

PWR plants have made efforts to maintain the long-term integrity of the steam generators (SG) by reducing the amount of corrosion products entering the secondary side of the SG. Iron entered the SG can cause several problems: degraded heat conductivity of the SG tubes in locations where iron is deposited, water level oscillations in the SG due to tube support plate hole blockage, and initiation and propagation of inter-granular attacks (IGA) and stress corrosion cracking (SCC). One of the most effective measures, high all-volatile treatment (AVT) chemistry has been applied to actual plants to reduce the flow-accelerated corrosion (FAC) coming from the carbon steel piping. The secondary water chemistry at Genkai NPS 1 and 2 changed, from the Low AVT chemistry to the High AVT chemistry, in November 2006. In this paper, we will describe the results of experiments in applying the use of High pH water in the secondary water system at Genkai NPS. ...

2009-02-01

241

Oil shale, tar sand, coal research, advanced exploratory process technology jointly sponsored research  

Energy Technology Data Exchange (ETDEWEB)

Accomplishments for the quarter are presented for the following areas of research: oil shale, tar sand, coal, advanced exploratory process technology, and jointly sponsored research. Oil shale research includes; oil shale process studies, environmental base studies for oil shale, and miscellaneous basic concept studies. Tar sand research covers process development. Coal research includes; underground coal gasification, coal combustion, integrated coal processing concepts, and solid waste management. Advanced exploratory process technology includes; advanced process concepts, advanced mitigation concepts, and oil and gas technology. Jointly sponsored research includes: organic and inorganic hazardous waste stabilization; development and validation of a standard test method for sequential batch extraction fluid; operation and evaluation of the CO[sub 2] HUFF-N-PUFF Process; fly ash binder for unsurfaced road aggregates; solid state NMR analysis of Mesa Verde Group, Greater Green River ...

1992-01-01

242

Method for controlling a coolant liquid surface of cooling system instruments in an atomic power plant  

International Nuclear Information System (INIS)

Object: To prevent coolant inventory within a cooling system loop in an atomic power plant from being varied depending on loads thereby relieving restriction of varied speed of coolant flow rate to lowering of a liquid surface due to short in coolant. Structure: Instruments such as a superheater, an evaporator, and the like, which constitute a cooling system loop in an atomic power plant, have a plurality of free liquid surface of coolant. Portions whose liquid surface is controlled and portions whose liquid surface is varied are adjusted in cross-sectional area so that the sum total of variation in coolant inventory in an instrument such as a superheater provided with an annulus portion in the center thereof and an inner cylindrical portion and a down-comer in the side thereof comes equal to that of variation in coolant inventory in an instrument such as an evaporator similar to the superheater. which is provided with an overflow pipe in its ...

243

Isolation condenser passive cooling of a nuclear reactor containment  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a nuclear system comprising a containment airspace in which a nuclear reactor pressure vessel is disposed there being a reactor core within the pressure vessel. It comprises a heat exchanger elevated a distance above the pressure vessel; a pool of water surrounding the heat exchanger; means for venting the pool of water to an environment outside the containment; a heat exchanger entry conduit within the containment, the entry conduit having an open lower end communicating with the containment space, and an upper end connected to the heat exchanger, water-containing heated fluid present in the containment airspace incident a pressure vessel loss of coolant event entering and flowing through the entry conduit into the heat exchanger for cooling the fluid to convert water vapor therein to a condensate and separate non-condensable gasses therefrom; a gravity driven cooling water pond-containing space, the gravity cooling water space being elevated ...

1991-10-22

244

Experimental study and performance evaluation of convective heat transfer augmentation with coiled wire inserts  

Energy Technology Data Exchange (ETDEWEB)

An experimental study of forced convection heat transfer at the inner tube wall of a double pipe heat exchanger with coiled wire inserts as heat transfer augmentation devices was performed over a turbulent flow region. The test results from twelve augmented tubes with inserts of different combinations of wire diameters (0.813, 1.016 and 1.575 mm) and pitches (2.82, 3.63, 5.08 and 8.47 mm) indicate that the turbulence promoters studied improve heat transfer by a factor of 1.4 to 2.24 compared with a smooth tube, although at a cost of 10-30 times increase in friction factor. A formula for presenting dimensionless exergy losses in a tubular heat exchanger is derived first and then the thermohydrodynamic optimum instead of economic optimum is found by minimizing the exergy losses in the system. From the heat transfer improvement number defined, it is observed that coiled wire turbulence promoters are more effective at Reynolds numbers less than ...

1992-12-01

245

Emergency reactor core cooling device  

International Nuclear Information System (INIS)

The device of the present invention improves reactor safety by suppressing lowering of water level in a shroud which surrounds a reactor core, even upon occurrence of rupture of pipelines in an emergency reactor core cooling system in a recycling pump-incorporated type reactor. Namely, an opening of each of cooling systems which forms the emergency reactor core cooling device in a reactor pressure vessel is disposed above the upper end of the reactor core. Further, it also comprises an independent high pressure water injection system, gravitational dropping type water injection system and an automatic depressurization system. With such a constitution, even if rupture of pipelines in the system should be assumed, coolants never flow directly from the shroud which surrounds the reactor core. In addition, there are no pipelines to be ruptured below the upper end of the reactor core with respect to the structure. Accordingly, a great amount of water can be stored in ...

1993-03-16

246

Effect of primary air content on formation of nitrogen oxides during combustion of Ehkibastuz coal  

Energy Technology Data Exchange (ETDEWEB)

Investigations are discussed carried out in a pilot plant at the Kaz. Power Engineering Scientific Research Institute into the effect of the amount of primary air in coal-dust flame on the final concentration of nitrogen oxides in flue gases. The tests were carried out in a 7500 mm high, 1600 mm dia vertical cylindrical combustion chamber having type P-57 burner, and air dispersed fuel plus additional air supplies located at the top. Amounts of coal dust fed by a drum feeder along the air pipe varied from 100-600 kg/h. The required air was supplied by 5000 m/sup 3//h Type TK-700/5 blowers at 0.04 MPa. Ehkibastuz coal samples contained: 1.3% moisture; 48.1% ash; 38.02% carbon; 2.56% hydrogen; 0.73% sulfur; 0.60% nitrogen; heat of combustion was 14.3 MJ/kg. Results obtained indicate that variations in the amount of primary air in swirl flow burners affect formation of fuel nitrogen; there is an optimum volume at which minimum quantities of ...

1986-01-01

247

CATHENA simulation of the WOLSUNG D_20 spill incident of 1984 November 25  

International Nuclear Information System (INIS)

The CATHENA (formerly ATHENA) has been used to simulate the thermalhydraulic behaviour of the WOLSUNG-1 CANDU-600 reactor during the D_20 spill incident of 1984 November 25. A 4-inch (nominal) Liquid Relief Valve inadvertently opened in the reactor auxiliary system during normal reactor operation, resulting in a discharge of heavy water from the primary heat transport system. The valve remained open for approximately 29 minutes. CATHENA is an advanced thermalhydraulic computer code for analysis of postulated loss-of-coolant accidents (LOCA) and transient faults in CANDU nuclear reactors. A full two-fluid (six-equation) representation of the two-phase flow is used. Component models are used to represent pumps, valves, critical discharge, etc., which are necessary to describe the behaviour of the CANDU system under upset conditions. Heat transfer between the fluid and piping walls (or fuel) is modelled using applicable correlations for boiling, ...

1986-06-09

248

Automated method for determining location and magnitude of leaks inside a PWR containment  

Energy Technology Data Exchange (ETDEWEB)

Thermal-hydraulics analysis can be used to determine location and magnitude of leaks inside a pressurized water reactor (PWR) containment, as required by plant technical specifications. The major advantage of this detection method is that it minimizes radiation exposure of maintenance personnel because most of the leak detection process is performed from the control room outside the containment. In addition, such a program allows for the elimination of pipe whip restraints and jet impingement shields, eliminating costs for maintenance of these supports and shields in older plants and lowering construction costs for new plants. Previously, only simple single-node containment models were used for determining leakage magnitude. This paper presents a more sophisticated multinode approach for determining the magnitude and location. The resulting sensitivities to leak can be programmed into the plant's computer system. In this way, the plant's computer ...

1986-01-01

249

The effects of gaseous environments on the mechanical failure of polyethylene pipe materials. Annual technical report 1 Nov 80-31 Oct 81  

Energy Technology Data Exchange (ETDEWEB)

Polyethylene gas piping is expected to be in service for times on the order of 50 years depending on service conditions. Therefore research research on piping materials and pipes has two principal objectives: (a) developing methods for predicting when a pipe will fail and (b) improving the material for piping. The prediction of long time failure hinges on the development of short time test methods which relate to long time failure. The improvement in the behavior of current materials also hinges on the use of test methods of short duration relative to the anticipated life time of the pipe in service. One of the primary criterion for an acceptable test method is that it produces the same type of failure as is observed after long time failure in service. It has been found that P.E. pipe material fails in a brittle mode after long periods of ...

1981-10-01

250

Study on potential threats against the leak tightness of the reactor containments due to pipe whips from hypothetical pipe ruptures in the steam- and feedwater systems; Utredning angaaende potentiella hot mot inneslutningars taethet paa grund av roerslag fraan taenkta roerbrott i aang- och matarvattenledningar  

Energy Technology Data Exchange (ETDEWEB)

Possible threats against the leak tightness of the reactor containments, due to pipe whips from hypothetical pipe ruptures in the steam- and feedwater systems, have been investigated for Forsmark 3/Oskarshamn 3, Ringhals 1, Oskarshamn 1 and Barsebaeck 2/Oskarshamn 2. Based on available drawings, such as installation drawings and isometric views of pipes, the pipe systems have been put together in new drawings with their bracing supports and containment walls. This inventory shows that pipe whips can occur on a number of places on the containments walls after hypothetical pipe ruptures in the steam- and main feedwater systems. In order to find out whether these pipe whips are real threats against the leak tightness, further analysis needs to be made but are out of the scope of this investigation.

2001-03-01

251

Pipe-to-pipe impact program  

Energy Technology Data Exchange (ETDEWEB)

The objective of this research was to determine the extent of damage that occurs when two pipes experience an impact event due to one whipping against the other. The research was conducted through experimental and analytical approaches. The former required the development of a specialized impact machine that could accelerate a whipping pipe with sufficient energy to cause failure of a target pipe that was heated and pressurized to Pressurized Water Reactor (PWR) conditions. Damage was measured in terms of crushing, bending, and failure. The results of the tests permitted the correlation between pipes of a certain size and the damage they could cause when impacting with a certain amount of known energy. These results were used to evaluate the pipe whip criteria in the Standard Review Plan 3.6.2-4. It was established that the criteria conditions did not fully represent the results ...

1987-05-01

252

GDH pipe break transient analysis of the RBMK - 1500.  

Energy Technology Data Exchange (ETDEWEB)

Presented in this paper is the transient analysis of a Group Distribution Header (GDH) following a guillotine break at the end of the header. The GDH is the most important component of reactor safety in case of accidents. Emergency Core Cooling System (ECCS) piping is connected to the GDH piping such that, during an accident, coolant passes from the GDH into the ECCS. The GDH that is propelled into motion after a guillotine break can impact neighboring GDH pipes or the nearest wall of the compartment. The cases of GDH impact on an adjacent GDH and its attached piping are investigated in this paper. A whipping RBMK-1500 GDH along with neighboring concrete walls and pipelines is modeled using finite elements. The finite element code NEPTUNE used in this study enables a dynamic pipe whip structural analysis that accommodates large displacements and nonlinear material characteristics. ...

2002-05-15

253

Calorimetric measurements of emittance of pipe surfaces: influence of enclosure diameter, test pipe length, and an argon atmosphere  

Energy Technology Data Exchange (ETDEWEB)

Additional results using a calorimetric technique for measuring the total hemispherical emittance of pipe surfaces from 400 to 600 K are described. Two different Pyrex pipe enclosures were used, one of 15 cm i.d. and the other of 30 cm i.d. An error analysis showed that the larger diameter Pyrex pipe should have a smaller error, but the difference was negligible for the 4.4-cm test pipe diameter used. Measurements on a short length of a previously-measured pipe agreed with earlier measurements, but only over the temperature range of the measurements. While the technique normally uses a vacuum to minimize nonradiative heat transfer, measurements were done succesfully with an argon atmosphere in a closed system. A nickel-plated pipe, measured first in a vacuum and then in an argon atmosphere, allowed calculation of an effective convective heat-transfer coefficient ...

1981-10-01

254

Process development for continuous crystallization of fat under laminar shear  

British Library Electronic Table of Contents (United Kingdom)

A novel continuous laminar shear structuring crystallizer with a suitable cooling system was designed and built. This is a new method to continuously crystallize edible fat in the desirable polymorphic form from the melt while being uniformly sheared.The machine consists of four main sections: Feed unit, shearing mechanism, cooling system and power unit. In each of these sections specific design considerations are taken into account which makes the process controllable and continuous. The shearing unit is made of two concentric cylinders. The internal cylinder is stationary and has a cooling system inside for temperature control. The outer cylinder rotates to produce a uniform shear in the sample fluid placed in the 1.5mm gap between the cylinders. The sample's feed rate is controlled whil...

2008-01-01

256

WIPS: computer code for whip and impact analysis of piping systems. Summary report  

Energy Technology Data Exchange (ETDEWEB)

WIPS (Whip and Impact of Piping Systems) is a special purpose computer code for the structural analysis of pipe whip dynamic effects following a postulated pipe rupture. WIPS has been developed primarily to provide support for the pipe whip analysis procedures described in Section 3.6.2 of the US Nuclear Regulatory Commission Standard Review Plan. This report summarizes the purpose and scope of the WIPS development effort, identifying those clauses in the Standard Review Plan which refer to pipe whip analysis, and indicating how the WIPS code can be used to provide supporting data. Detailed information on use of the code is contained in accompanying reports which cover: (1) user instructions; (2) theory; (3) programming procedures; and (4) verification examples.

1984-06-01

257

Integrity of feedwater and main steam piping in KWU light water reactor plants  

Energy Technology Data Exchange (ETDEWEB)

New standard catalogs for piping, supports, and valves have been introduced by Kraftwerk Union (KWU) for the first time in its Convoy series of PWR plants. These catalogs, underlying regulatory codes, and newly developed KWU specifications are described. Feedwater and main steam piping systems within the containment, including pipe supports and valves, are used to demonstrate the high quality level of piping technology achieved in the Federal Republic of Germany. Such quality standards ensure the integrity of single components as well as of the entire system, so that, under certain conditions, pipe whip restraints against postulated breaks have become unnecessary. The quality aspects apply basically for both PWR and BWR plants of KWU.

1986-07-01

258

Influence of feed water distribution pipe replacement on the water chemistry in the steam generator at Loviisa NPP  

International Nuclear Information System (INIS)

Imatran Voima Oy , (IVO) operates two Russian designed nuclear power plants of type VVER440/213. Unit 1 has been operating since 1977 and unit 2 since 1981. First damage of feed water distribution (FWD) pipes was observed in 1989. In closer examinations FWD-pipe T-connection and distribution nozzles suffered from severe erosion corrosion damage. Similar damages have been found also in other VVER-440 type NPPs. In 1994 the first FWD-pipe was replaced by a new design mounted over the tube bundle instead of the old FWD-pipe, which was located inside the tube bundle. The purpose of this paper is to describe the new FWD-pipe and discuss its effects on the steam generator chemistry. (author)

1998-06-01

259

Glass-heat-pipe evacuated-tube solar collector  

Science.gov (United States)

A glass heat pipe is adapted for use as a solar energy absorber in an evacuated tube solar collector and for transferring the absorbed solar energy to a working fluid medium or heat sink for storage or practical use. A capillary wick is formed of granular glass particles fused together by heat on the inside surface of the heat pipe with a water glass binder solution to enhance capillary drive distribution of the thermal transfer fluid in the heat pipe throughout the entire inside surface of the evaporator portion of the heat pipe. Selective coatings are used on the heat pipe surface to maximize solar absorption and minimize energy radiation, and the glass wick can alternatively be fabricated with granular particles of black glass or obsidian.

1981-08-06

260

Apparatus for total hemispherical emittance measurements of full-scale receiver pipes from 100 to 300 C  

Energy Technology Data Exchange (ETDEWEB)

An apparatus is described for measuring the total hemispherical emittance of pipes of a length suitable for use in a prototype solar collector. The calorimetric method used requires measurements of the temperatures of the surface of the test pipe and of a concentric outer cylinder and measurement of the electrical power used to heat the test pipe. Measurements were made of the total hemispherical emittance of black chrome, nickel, and bare steel pipes as a function of temperature. The emittance of the black chrome surfaces increased significantly from an extrapolated value of about 0.1 at 25 deg C to values on the order of 0.3-0.4 at 300 deg C. The extrapolated values for black chrome agreed with measurements made using other techniques at room temperature. The results for the nickel-plated pipe agreed with total emittance calculated from spectral reflectance data.

1981-01-01

261

Effects on surface hydrology and near-surface hydrogeology of an open repository in Laxemar Results of modelling with MIKE SHE  

Energy Technology Data Exchange (ETDEWEB)

This report presents the methodology and the results from the modelling of an open repository for spent nuclear fuel in Laxemar. Specifically, the present work analyses the hydrological effects of the planned repository during the construction and operational phases when it is open, i.e. air-filled, and hence may cause a disturbance of the hydrological conditions in the surroundings. The numerical modelling is based on the SDM-Site Laxemar MIKE SHE model. The modelling was divided into three steps. The first step was to update the SDM-Site Laxemar model with a new hydrogeological bedrock model. The other main updates were an increase of the depth of the MIKE SHE model domain, enhanced vertical computational resolution and that the drainage of the Aespoe Hard Rock Laboratory was included in the model. The resulting model was used to simulate undisturbed natural conditions. The next step was to describe the open repository conditions, using Laxemar layout D2, by implementing the access ...

2009-10-15

262

A Scheme of 3-D Breakdown-whip Analysis Methodology for High Energy Piping  

Energy Technology Data Exchange (ETDEWEB)

High energy piping systems are operated with either or both conditions of maximum operating temperature exceeding 200 .deg. F(93.3 .deg. C) or maximum operating pressure exceeding 275 psig(19.3kg/cm{sup 2}) during normal operating conditions in nuclear power plants. A high energy pipe failure is postulated in branches or piping that runs larger than one inch nominal diameter. The resultant consequences of these postulated pipe breaks must be analyzed for the effect on maintenance of plant safe shutdown capability, containment integrity. And the analyzed results must be applied to the system design so that a pipe failure can not damage essential systems to an extent of impairing design function nor affect necessary component operability. The considerable effects of pipe break are as follows; dynamic effects such as pipe whip, jet impingement ...

2007-10-15

263

Report of the US Nuclear Regulatory Commission Piping Review Committee. Volume 3. Evaluation of potential for pipe breaks  

Energy Technology Data Exchange (ETDEWEB)

The Executive Director for Operations (EDO) in establishing the Piping Review Committee concurred in its overall scope that included an evaluation of the potential for pipe breaks. The Pipe Break Task Group has responded to this directive. This report summarizes a review of regulatory documents and contains the Task Group's recommendations for application of the leak-before-break (LBB) approach to the NRC licensing process. The LBB approach means the application of fracture mechanics technology to demonstrate that high energy fluid piping is very unlikely to experience double-ended ruptures or their equivalent as longitudinal or diagonal splits. The Task Group's reommendations and discussion are founded on current and ongoing NRC staff actions as presented in Section 3.0 of this report. Additional more detailed comments and discussion are presented in Section 5.0 and in Appendices A ...

1984-11-01

264

Refinement and evaluation of crack-opening-area analyses for circumferential through-wall cracks in pipes  

Energy Technology Data Exchange (ETDEWEB)

Leak-before-break (LBB) analyses for circumferentially cracked pipes are currently being conducted in the nuclear industry to justify elimination of pipe whip restraints and jet impingement shields which are present because of the expected dynamic effects from pipe rupture. The application of the LBB methodology frequently requires calculation of leak rates. These leak rates depend on the crack-opening area of a through-wall crack in the pipe. In addition to LBB analyses, which assume a hypothetical flaw size, there is also interest in the integrity of actual leaking cracks corresponding to current leakage detection requirements in NRC Regulatory Guide 1.45, or for assessing temporary repair of Class 2 and 3 pipes that have leaks as are being evaluated in ASME Section 11. This study was requested by the NRC to review, evaluate, and refine current analytical models for ...

1995-04-01

265

Oscillating line travel pipe cleaning machine  

Energy Technology Data Exchange (ETDEWEB)

A major problem in the maintenance and rehabilitation of pipelines is the removal of the original coating system, particularly in cases where the coating contains sticky components or adhesives. It has been found that such coatings can be removed by use of a cleaning machine with a plurality of counter-rotating carbide-tipped tools mounted to an oscillating head embracing the pipe, and which is operable at the same time to travel along the length of the pipe. Such a machine can be designed to effect a positive, gentle milling operation on the pipe surface to remove the coating efficiently and at relatively low power consumption. A particular advantage of the pipe cleaning machine of the invention is that its design and manner of operation allows it to be used in the field to clean an uncovered section of pipeline, for example a natural gas pipeline, without the requirement of removing the pipeline ...

1992-04-28

266

Northward Market Extension for Passive Solar Water Heaters by Using Pipe Freeze Protection with Freeze-Tolerant Piping: Preprint  

Energy Technology Data Exchange (ETDEWEB)

Conference paper regarding research in freeze-protection methods that could extend market acceptance for passive solar domestic water heating systems in more northern climates if the U.S.

2006-05-01

267

Four-inch pipe whip test under BWR LOCA conditions effect of overhang length  

Energy Technology Data Exchange (ETDEWEB)

Pipe whip tests or jet discharge tests have been performed at the Japan Atomic Energy Research Institute, which simulate the instantaneous guillotine break of primary coolant piping in nuclear power plants. This paper describes the results of the 4-inch pipe whip tests(RUN 5407, 5501, 5504, 5603), under the BWR LOCA conditions, which were performed from 1979 to 1981. The test pressure was 6.8 MPa and test temperature 285/sup 0/C. In these tests, clearance was kept constant at the value of 100 mm and overhang lengths were 250, 400, 550 and 1,000 mm, respectively. The main purpose of these tests is to investigate the effect of overhang length on pipe whip behavior. From the tests results, the pipe movement is effectively limited by the restraints if the overhang length is 250 mm or 400 mm. The deformation of the test pipe and restraints becomes large with ...

1983-03-01

268

Cracking resistance in steam pipe fittings having various microdamage levels  

Energy Technology Data Exchange (ETDEWEB)

Cracking resistance and metal damage are considered in relation to structural state for steam-pipe fittings during use. An approximate scheme is given for estimating the maximum permissible operating time in the plastic state in relation to the depth of an observed crack-type defect.

1995-05-01

269

Applicability of leak-before-break criteria  

Energy Technology Data Exchange (ETDEWEB)

On February 1, 1984, the US Nuclear Regulatory Commission issued Generic Letter 84-04 on the subject of postulated pipe breaks in pressurized water reactor (PWR) primary coolant loops, opening the way for pipe-whip restraint exemptions. The letter substitutes the leak-before-break (LBB) criteria for the double-ended guillotine break regarding PWR primary reactor coolant system (RCS) piping and asymmetric blowdown loads. The LBB criterion refers to the fact that a piping flaw will leak before it breaks. The current requirement to provide pipe-whip restraints is applied within the plant to all high-energy piping with a potential for damaging structures, systems, and components essential to safe reactor shutdown. This includes primary RCS piping 30 in. and larger as well as smaller piping systems. A study was performed to ...

1986-01-01

270

Structural integrity evaluation of fuel test loop submerged in water subjected to postulated pipe rupture  

Energy Technology Data Exchange (ETDEWEB)

The structural integrity of the Fuel Test Loop(FTL) in a Korean experimental reactor is evaluated when the FTL, submerged in a water environment, is subjected to a postulated pipe rupture. The analyses are performed under static and dynamic conditions, imposing the thrust force history at each postulated pipe rupture section. Through analysis the following results are found: 1) A double ended guillotine can not be expected based on the toughness of the material, 2) the structural integrity of the chimney surrounding the FTL would not impede the structural integrity by the pipe whip. All analyses are performed by finite element methods.

2000-02-01

271

Fording Coal reduces preparation plant downtime with wear resistant lining  

Energy Technology Data Exchange (ETDEWEB)

Prior to 1986, the abrasive coking coal processed in the coal preparation plant at the Fording River operation at Elkford, British Columbia, was destroying the mild steel straight pipe and elbows at such a rate that they were having to be replaced annually and every 6-8 months respectively. To solve the problem, Fording River began to replace existing pipe and elbows with fused-cast, basalt-lined abrasion-resistant pipe, elbows and fittings manufactured by Abresist Corp. of Urbana, Indiana. The Abresist straight pipe has lasted 7 seven years and the Abresist elbows 5 years and both are still in use. 2 photos.

1994-04-01

272

Failure analysis on a ruptured petrochemical pipe  

Energy Technology Data Exchange (ETDEWEB)

The failure took place on a welded elbow pipe which exhibited a catastrophic transverse rupture. The failure was located on the welding HAZ region, parallel to the welding path. Branching cracks were detected at the edge of the rupture area. Deposits of corrosion products were also spotted. The optical microscope analysis showed the presence of transgranular failures which were related to the stress corrosion cracking (SCC) and were predominantly caused by the welding residual stress. The significant difference in hardness between the welded area and the pipe confirmed the findings. Moreover, the failure was also caused by the low Mo content in the stainless steel pipe which was detected by means of spark emission spectrometer. (orig.)

2010-08-15

273
274

BURST STRENGTH AND NON-DESTRUCTIVE EVALUTION OF COMPOSITE PIPES AND PIPE COUPLINGS WITH DEFECTS (TOP 48)  

Environmental Research Database

ObjectivesObjectives Not AvailableDescriptionTo determine the effects of water penetration on the burst strength of filament wound composite pipes which have been damaged by impact and then subjected to long term pressurisation with sea water. ~%~ To monitor and characterise the damage and effects of sea water penetration using ultrasonic NDT. To determine the burst strength of bonded composite pipe joints with and without defects and to see whether the defects can be detected using ultrasonic NDT. [continued...

1996-01-31

275

Generalized correlation for condensation on vertical fluted surfaces  

Energy Technology Data Exchange (ETDEWEB)

A correlation was developed for laminar film condensation on vertical fluted surfaces. The theoretical analysis of Panchal and Bell was used for defining important physical property groups. The experimental data of Combs et al. were used to validate the proposed correlation. The experimental database used in the present study included four flute geometries that could be approximated to cosine-type flutes and seven fluids. The resulting correlation can predict the average condensate heat transfer coefficient within {+-}20%.

1994-10-01

276

TRACE code modeling of the horizontal steam generator of the PACTEL facility and calculation of a loss-of-feedwater experiment  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the modeling of horizontal steam generator with the TRACE code and calculation results of a loss-of-feedwater (LOF-10) experiment at the PACTEL facility. Parallel Channel Test Loop (PACTEL) is an integral test facility for a VVER-440 type nuclear reactor. The main objectives were to prepare a simulation model for its horizontal steam generator with the TRACE thermal hydraulic code and assess different modeling options of the code. PACTEL experiment LOF-10 was chosen for this assessment. The calculation results showed that TRACE is capable in simulating horizontal steam generator behavior both in steady state and during loss-of-feedwater transient. The phenomenon of heat transfer from primary to secondary side, steam superheating and flow reversal in the lowest heat exchange tubes were studied in detail. Different nodalization options were introduced. In the simulation of PACTEL loss-of-feedwater experiment LOF-10, the main parameters of the ...

2010-11-15

277

TRACE code modeling of the horizontal steam generator of the PACTEL facility and calculation of a loss-of-feedwater experiment  

International Nuclear Information System (INIS)

This paper describes the modeling of horizontal steam generator with the TRACE code and calculation results of a loss-of-feedwater (LOF-10) experiment at the PACTEL facility. Parallel Channel Test Loop (PACTEL) is an integral test facility for a VVER-440 type nuclear reactor. The main objectives were to prepare a simulation model for its horizontal steam generator with the TRACE thermal hydraulic code and assess different modeling options of the code. PACTEL experiment LOF-10 was chosen for this assessment. The calculation results showed that TRACE is capable in simulating horizontal steam generator behavior both in steady state and during loss-of-feedwater transient. The phenomenon of heat transfer from primary to secondary side, steam superheating and flow reversal in the lowest heat exchange tubes were studied in detail. Different nodalization options were introduced. In the simulation of PACTEL loss-of-feedwater experiment LOF-10, the main parameters of the ...

2010-11-01

278

Numerical Modeling of Reactive Multiphase Flow for FCC and Hot Gas Desulfurization Circulating Fluidized Beds  

Energy Technology Data Exchange (ETDEWEB)

This work was carried out to understand the behavior of the solid and gas phases in a CFB riser. Only the riser is modeled as a straight pipe. A model with linear algebraic approximation to solids viscosity of the form, {musubs} = 5.34{epsisubs}, ({espisubs} is the solids volume fraction) with an appropriate boundary condition at the wall obtained by approximate momentum balance solution at the wall to acount for the solids recirculation is tested against experimental results. The work done was to predict the flow patterns in the CFB risers from available experimental data, including data from a 7.5-cm-ID CFB riser at the Illinois Institute of Technology and data from a 20.0-cm-ID CFB riser at the Particulate Solid Research, Inc., facility. This research aims at modeling the removal of hydrogen sulfide from hot coal gas using zinc oxide as the sorbent in a circulating fluidized bed and in the process indentifying the parameters that affect the ...

2005-07-01

279

Through Weld Inspection of Wrought Stainless Steel Piping Using Phased Arrays  

Energy Technology Data Exchange (ETDEWEB)

Outline: Discuss far-side weld problem and phased array techniques applied. Describe laboratory work on flawed piping specimens using L- and S-wave arrays and provide synopsis of results. Discuss conclusions ofr capability of phased array as applied to austenitic welds. Research Approach: Evaluate phased arrays on unifornly-welded piping specimens. Apply best methods to non-uniform welds. Correlate acoustic responses as function of weld microstructures.

2004-12-31

280

Structural integrity evaluation of FTL in-pool piping  

Energy Technology Data Exchange (ETDEWEB)

HANARO fuel test loop will be equipped in HANARO to obtain the development betterment of advanced fuel and materials through the irradiation test. The object of this study is to evaluate the structural integrity of FTL in-pool piping by investigating a dynamic analysis of the loop containing a postulated rupture section. The method to perform the dynamic analysis and structural integrity evaluation caused by the pipe whip in water environment can be a reference for a similar structural integrity evaluation. (author). 7 refs., 39 tabs., 34 figs.

1998-05-01

281

Pressure surge analyses for conventional and nuclear power plants. Druckstossanalysen fuer konventionelle und nukleare Kraftwerke  

Energy Technology Data Exchange (ETDEWEB)

There is need of pressure surge analyses when valves or pumps are activated or piping systems fail (pipe rupture). Based on actual problems the influences of boundary conditions upon fluid simulation results are discussed. Hints concerning realistic dynamic analyses of piping systems are presented. Some of the simulations results are compared with measurements. (orig.)

1993-09-01

282

Heat pipes and two-phase loops with capillary pumping; Caloducs et boucles diphasiques a pompage capillaire  

Energy Technology Data Exchange (ETDEWEB)

This workshop on heat pipes and two-phase capillary pumping loops was organized by the French society of thermal engineers. The 11 papers presented during this workshop deal with the study of thermal performances of heat pipes and on their applications in power electronics (cooling of components), and their use in satellites, aircrafts and trains. (J.S.)

1996-12-31

283

Developing DB system of piping reliability  

Energy Technology Data Exchange (ETDEWEB)

Developing DB system of piping reliability including the population data and service history of damaged piping for pilot power plant. Total weld counts of shop welds, field welds and welds for measuring instruments for 14 systems of Kori unit 3. Total weld counts of shop welds, field welds and welds for measuring instruments for 12 systems of Wolsung unit 2.

2005-03-15

284

Design basis for protection of light water nuclear power plants against effects of postulated pipe rupture  

Energy Technology Data Exchange (ETDEWEB)

This standard addresses the design bases for light water reactor, nuclear power plant structures and components essential for the protection of public health and safety from the potential adverse effects of pipe whip, jet impingement, pressurization of compartments outside containment, environmental conditions and flooding associated with a postulated pipe rupture. The design bases for missile protection and the design bases for containment pressurization are not within this standard.

1981-01-01

285

American National Standard: design basis for protection of light water nuclear power plants against effects of postulated pipe rupture  

Energy Technology Data Exchange (ETDEWEB)

This standard addresses the design bases for light water reactor, nuclear power plant structures and components essential for the protection of public health and safety from the potential adverse effects of pipe whip, jet impingement, pressurization of compartments outside containment, environmental conditions and flooding associated with a postulated pipe rupture. The design bases for missile protection and the design bases for containment pressurization are not within this standard.

1980-12-31

286

Tensile properties and bending formability of drawn magnesium alloy pipes  

Energy Technology Data Exchange (ETDEWEB)

Magnesium alloys are being increasingly utilized in a variety of fields as an alternative material to organic materials and aluminum alloys, owing to excellent properties. Those include low density, and excellent damping properties. When compared to organic materials, furthermore, Mg alloy excels at recyclability, heat radiation, and electromagnetic-shielding. Though most of magnesium alloy products are manufactured through die-casting and thixo-molding at present, the demand for the expanding of magnesium wrought alloy market is increasing. Taking full advantage of a drawing technique and applying it to the conventional extruded pipe, we have developed a new type of magnesium alloy pipe. The strength of the developed pipe is significantly higher than that of the conventional one, either extruded or die-casting. Some of the excellent properties were obtained from fundamental tests performed with the developed ...

2003-07-01

287

Energy absorbers used against impact loading  

International Nuclear Information System (INIS)

In the WWER-440 reactor the primary piping consists of six horizontal loops going radially from the pressure vessel, each loop having a horizontal steam generator. In this reactor type the relatively long primary piping with many curved sections requires special attention in order to successfully eliminate the consequences of the design basis accident. Emergency supports are located in appropriate places to restrict the movements of the pipe. Under normal conditions there is a gap of some centimeters between the pipe and a support so that in the pipe can be deformed freely under changing loads. This paper deals with those energy-absorbing structures used at the Loviisa Nuclear Power Plant for protection against impact loading. Places and circumstances where energy-absorbing structures are employed are specified. Development and design of impact absorber elements are discussed and ...

1975-09-08

288

Blowdown thrust force under pipe rupture accident. Pt. 1. Experimental evaluations of blowdown thrust force and decompression characteristics  

Energy Technology Data Exchange (ETDEWEB)

Blowdown thrust forces and decompression characteristics were evaluated concerning the jet discharge or pipe whip tests with a 4-inch or 6-inch diameter pipe under PWR LOCA or BWR LOCA conditions related to pipe rupture accidents in nuclear power plants. This paper presents experimental evaluations of time-dependent and maximum blowdown thrust forces, and evaluations of decompression characteristics under instantaneous pipe rupture conditions. The following items are discussed: the peak value of the blowdown thrust force, the jet thrust coefficient for the maximum blowdown thrust force, the pressure recovery after break, and the relationship between the pressure undershoot of the sudden decompression and the decompression rate.

1984-06-01

289

Application of probabilistic methods to validate NPP pipewhip impact simulations  

British Library Electronic Table of Contents (United Kingdom)

Piping in nuclear power plants is vital to the proper operation and safety of these facilities. To assure safety in the unlikely event of a pipe break, it is necessary to evaluate the consequences from the resulting whipping pipe on neighboring components and structures. Numerical simulations allow for rapid evaluation of these consequences. Before simulations can be accepted, however, the methodology and computer codes must be validated against experimental results. This paper uses a probabilistic approach to validate pipe whip simulations against limited experimental results. Probabilistic analysis software was developed and coupled to existing deterministic finite element software. An example of a whipping pipe impacting against a reinforced concrete slab was simulated. The described pr...

2006-01-01

290

Application of leak-before-break approach to PWR piping designed by Babcock and Wilcox: Final report  

Energy Technology Data Exchange (ETDEWEB)

Recently, the leak-before-break (LBB) concept has been used successfully to eliminate some pipe whip restraints, snubbers and jet impingement shields from the primary reactor cooling system piping of pressurized water reactors. This has resulted in substantial savings in maintenance costs, reductions in radiation exposure of plant service personnel, and has enhanced the overall safety of nuclear power plants. This study provides guidelines to utilities in expanding the application of the LBB concept to additional pipe systems and it couples the concept with hardware optimization. Seven high energy piping systems were investigated for technical feasibility in using the LBB concept. The results indicate that some of these seven lines are good candidates for the leak-before-break application.

1987-01-01

291

A study on the transient analysis of pipe and restraint due to impact loading  

Energy Technology Data Exchange (ETDEWEB)

In this study, experiments were performed for pipe whip phenomena simulation. The analytical method was developed by combining several kinds of elements in ABAQUS computer code, standard version 5.2 . The transient analytical and the experimental results of the pipe whip test using 6 inch diameter pipe and U-shaped restraints are presented. It is shown that the adequate clearance decreases the restraint strains. As the overhang length increased, the maximum strain of restraints decreased. When the impact force increased, the maximum restraint strain increased slightly. The analytical models simulate the experimental impact phenomena very precisely, with slight conservatism. It is verified that the analytical method developed is very suitable to pipe whip phenomena analysis in nuclear power plants. 6 refs., 10 figs., 1 tab.

1995-12-31

292

Nonlinear dynamic analysis of pipe whip tests. Final report  

Energy Technology Data Exchange (ETDEWEB)

This is a numerical verification of two groups of pipe whip tests sponsored or cosponsored by EPRI. Experimental data of the two pipe whip tests, one by Tennessee Valley Authority (TVA) and by FRAMATOME/CEA, were provided by EPRI. A nonlinear finite element code, ABAQUS-EPGEN, developed under partial sponsorship by EPRI was used for modeling the pipe whip tests. Beam elements together with an equivalent nonlinear spring element or a partial shell mesh were used to model pipes and elbow in the pipe whip tests. Material nonlinearity due to plasticity, strain rate effects, and temperature, as well as geometric nonlinearity due to large rotation and boundary conditions were included in the study. Effects of strain rate and modeling techniques were assessed. Results by current industry approach were also included as a reference solution. This report can be used as a guideline for ...

1986-05-01

293

Leak-before-break strategy for CANDU primary piping systems  

Energy Technology Data Exchange (ETDEWEB)

Recent advances in elastic-plastic fracture mechanics have made it possible to assess the stability of cracks in ductile piping systems. These technological developments have been used by Ontario Hydro as the nucleus of an approach for demonstrating that CANDU primary heat transport piping systems will not break catastrophically; at worst they would leak at a detectable rate. This leak-before-break approach has been taken on the Darlington nuclear generating station as a design stage alternative to the provision of pipe whip restraints on large diameter, primary heat transport system piping. Positive conclusions reached via this approach are considered sufficient to exclude the requirement to provide protective devices, such as pipe whip restraints. In arriving at the proposed leak-before-break approach a review of current and proposed leak-before-break licensing positions of other ...

1986-01-01

294

FFTF report: FFTF piping installation and welding techniques  

International Nuclear Information System (INIS)

The main sodium piping with a diameter of 16'' or 28 '' is being installed at the FFTF construction site starting in December 1974. The supplier and authority demarcations are: Combustion Engineering supplies the reactor vessel, guard vessel and adjoining pipes and uses the machine welding equipment ''Dimetrics''; for the piping system of the primary and secondary loops the pipes manufactured by Rollmet at HUICO, Pasco, were delivered and prefabricated there, as far as compatible with the installation. ''Astroarc'' welding machines are used by Bechtel for the piping prefabrication in the weld laboratory as well as on site at the construction site. Technical welding problems occurring during the course of the installation at the construction site and several during this time are described. At present 6 weld seams in the reactor and 14 weld seams in the secondary loop are accepted. ...

295

Evaluation of pipe whip impacts on neighboring piping and walls of the Ignalina Nuclear Power Plant  

Energy Technology Data Exchange (ETDEWEB)

Stress corrosion cracks have been discovered in Group Distribution Headers (GDH) at the Ignalina and Chernobyl Nuclear Power Plants. This increases the probability that a guillotine pipe break can occur that creates a whipping pipe (GDH) with the potential to damage surrounding structures-i.e. adjacent GDH and its attached piping or adjacent reinforced concrete compartment wall. The GDH is the most important component for reactor safety in case of an accident. Emergency Core Cooling System (ECCS) piping is connected to the GDH piping such that, during an accident, coolant passes from the ECSS into the GDH. Presented in this paper is the transient analysis of a Group Distribution Header following a guillotine break at the blind end of the header. Using a very conservative force loading function, the transient response of a whipping RBMK-1500 GDH along with neighboring concrete walls ...

2007-04-15

296

Assessment of value-impact associated with the elimination of postulated pipe ruptures from the design basis for nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

The US Nuclear Regulatory Commission is proposing to amend the regulations that currently require that the design basis for nuclear power plants include the postulation of dynamic effects from loss of coolant accidents up to and including the double-ended rupture of the largest pipe in the reactor coolant system. Proposed modifications would allow analyses to serve as a sufficient basis for excluding dynamic effects, including but not necessarily limited to pipe whip and jet impingement, associated with specific pipe ruptures. Only dynamic effects would be impacted; current design requirements for containment sizing and discharge capacity of emergency core cooling systems would remain unchanged. This report presents a detailed analysis of value-impact associated with the proposed amendment for PWR reactor coolant loop piping and for BWR recirculation loop piping. The effect of ...

1985-03-29

297

Heat transfer augmentation of a circular pipe flow using nano-particle layers  

International Nuclear Information System (INIS)

For the advanced fusion reactor FFHR2 (Force Free Helical Reactor) that has been proposed by NIFS, molten salt Flibe (LiF:BeF2=64:36) breeder blanket system is selected because of Flibe's features such as chemical stability, low-pressure operation and low electric conductivity. The Flibe is however high Prandtl number fluid since it has high viscosity and low thermal conductivity. Therefore its heat transfer performance is low compared with liquid Li or Pb-Li. In addition to heat removal of 1MW/m2 on the first wall, electrolysis of molten salt due to MHD effect will take place under high flow rate condition. This indicates that heat transfer enhancement under low flow rate is essential for the Flibe blanket system. In our laboratory, heat transfer characteristics of molten salt HTS (KNO3:NaNO2:NaNO3=53:40:7), have been evaluated, which is used as a simulant fluid of Flibe from the points of view of Be's toxicity and similar Prandtl number. In ...

2007-10-05

298

Reynolds Number Effects in Transonic Flow  

Science.gov (United States)

... of drag measurements with the AGARD Nozzle Afterbody ... are discussed separately from flows with a ... bubbles introduce typical flow phenomena that ...

1988-12-01

299

Flow Control  

Science.gov (United States)

... 65th AGARD Fluid Dynamics Symposium, Madrid, Spain, October ... of research programs on flow control ... separation, and delta wing flows formed the ...

1991-04-30

300

Experimental studies of 4-inch pipe whip test under BWR LOCA conditions  

Energy Technology Data Exchange (ETDEWEB)

Pipe whip tests or jet discharge tests have been performed at the Japan Atomic Energy Research Institute, which simulate the instantaneous circumferential guillotine break of primary coolant piping in nuclear power plants. The present paper describes the results of the pipe whip tests using test pipes of 4 inch diameter, under the BWR LOCA conditions, which were performed from 1979 to 1981. The tests were carried out at an initial pressure of about 6.8 MPa and an initial temperature of about 285/sup 0/C. The test pipe was 114.3 mm (4 in) in diameter, 8.6 mm in thickness and 4500 mm in length. The four pipe whip restraints used in the tests were the U-bar type of 8 mm in diameter and frabricated from Type 304 stainless steel. The experimental parameters were the clearance (30, 50 and 100 mm) and the overhang length (250, 400, 550 and 1000 mm). The main purpose of ...

1983-10-01

301

PROBE FOR FLOW PASSAGE INSPECTION  

J-STORE (Japan)

Full Text Available

2007-05-11

302

On Issues Concerning Flow Separation and Vortical Flows in Three ...  

Science.gov (United States)

impflrtant to the understanding of complex vortical flows. ... tions like the slender wing, flow separations are controlled in the s,. ...... 10, AGARD LS-121, Dec. ...

304

Industrial-process control valves Part2 : Flow capacity Section Four : Inherent flow characteristics and rangeability  

CERN Document Server

Industrial-process control valves Part2 : Flow capacity Section Four : Inherent flow characteristics and rangeability

1989-01-01

306

Feasibility study for use of the natural convection shutdown heat removal test facility (NSTF) for VHTR water-cooled RCCS shutdown  

International Nuclear Information System (INIS)

In summary, a scaling analysis of a water-cooled Reactor Cavity Cooling System (RCCS) system was performed based on generic information on the RCCS design of PBMR. The analysis demonstrates that the water-cooled RCCS can be simulated at the ANL NSTF facility at a prototypic scale in the lateral direction and about half scale in the vertical direction. Because, by necessity, the scaling is based on a number of approximations, and because no analytical information is available on the performance of a reference water-cooled RCCS, the scaling analysis presented here needs to be 'validated' by analysis of the steady state and transient performance of a reference water-cooled RCCS design. The analysis of the RCCS performance by CFD and system codes presents a number of challenges including: strong 3-D effects in the cavity and the RCCS tubes; simulation of turbulence in flows characterized by natural circulation, high Rayleigh numbers and low Reynolds numbers; validity ...

307

Effect of humidity in a mixture on combustion (Part 1). Effect on laminar burning velocity  

Energy Technology Data Exchange (ETDEWEB)

In order to investigate the effect of humidity on laminar burning velocity(S), the effect of humidity on the combustion reaction and radiation intensity was studied, taking account of dilution gases such as CO/sub 2/ and Ar which has the approximately identical characteristics to exhaust gas circulation(EGR) gas used to prevent NOx discharge from engines. According to the heat reaction theory, mean specific heat(C) of mixture, mean molecular weight(M) and adiabatic flame temperature(T) etc. were said to affect S but from experimental results, the effect of M and C could be ignored, compared with the effect of T. The relationship between S and H/sub 2/O, Ar of CO/sub 2/% in mixture of diluted gases was clarified. The effect of H/sub 2/O on S was mainly caused by changes of T. The effect of radical C/sub 2/, CH and OH on radiation intensity was similar to that of H/sub 2/O and Ar and the effect of H/sub 2/O on combustion was found only to be the physical effect. (10 ...

1987-08-25

308

Probabilistic fracture assessment of TAPP 3-4 PHT piping  

International Nuclear Information System (INIS)

Methodology based on probabilistic fracture mechanics (PFM) is finding increasing acceptability in demonstrating safety of Nuclear Power Plant (NPP) piping. In PFM, the methods of fracture mechanics and reliability theory are combined for assessing the reliability of components, which contain cracks. In this work, reliability assessment of Tarapur Atomic Power Plant (TAPP) 3-4 Primary Heat Transport (PHT) piping is done using PFM. Monte Carlo simulation with stratified sampling is used as a variance reduction technique. PFM model assumes a pre-existing circumferential surface crack before the start of plant operation. The crack grows in size during the lifetime of the plant due to the fatigue loading. This part-through wall crack having escaped hydro-test and pre-service inspection, may result in either a through wall flaw (leak) or may lead to the rupture of the piping. R6 method is used as failure criteria. Steam ...

2005-12-01

309

Parametric study of pipe whip analysis  

Energy Technology Data Exchange (ETDEWEB)

In the Energy Balance Analysis Model (Standard Review Plan (USNRC, 1981), Section 3.6.2, ''Determination of Rupture Locations and Dynamic Effects Associated with the Postulated Rupture of Piping''), time dependence is not considered, and a constant blowdown thrust force is assumed. This force includes an amplification factor of 1.1 to account for potential effects of rebound. Many of the assumptions used in establishing the acceptance criteria, as stated in the Standard Review Plan, were based on engineering judgment and logic intended to assure upper bound design rather than on a mechanistic assessment of actual pipe rupture phenomena and their effects. As a result of the current practice an exceedingly conservative design may be introduced. This report represents a parametric study of the amplification factor to account for rebound effects in the Energy Balance Method. Of the 71 distinct cases we chose for ...

1987-10-01

310

Doubled-ended breaks in reactor primary piping. [Guillotine breaks  

Energy Technology Data Exchange (ETDEWEB)

Results indicate that the probability of double-ended guillotine break (DEGB) in the reactor coolant loop piping of Westinghouse and Combustion Engineering plants is extremely low. It is recommended that the NRC seriously consider eliminating DEGB as a design basis event for reactor coolant loop piping in Westinghouse plants. Pipe whip restraints on reactor coolant loop piping could then be excluded or removed, and the requirement to design supports to withstand asymmetric blowdown loads could be eliminated. It is also recommended that the current requirement to couple safe shutdown earthquake (SSE) and DEGB be eliminated. Recognizing however that seismically induced support failure is the weak link in the DEGB evaluation, it is recommended that the strength of component supports, currently designed for the combination of SSE plus DEGB, not be reduced. The study indicates that the probability of DEGB in ...

1984-10-01

311

Development of a combined ultrasonic and eddy current inspection system for examination of the internal surfaces of water-filled austenitic piping  

Energy Technology Data Exchange (ETDEWEB)

After October 1993, Swedish BWR power plant operators will be required to present an inspection concept which will facilitate the nondestructive examination of recirculation system piping. According to the pertinent Swedish codes and standards, such inspections will be required to focus on internal pipe surfaces. Since it is impossible for external inspections to cover all essential areas with the necessary degree of sensitivity (geometry, beam attenuation), Siemens-KWU was commissioned to develop an inspection system which combines ultrasonic search units and eddy current probes to produce the required degree of examination sensitivity. A pipe crawler was developed to transport the inspection unit. This device can be used for the inspection of circumferential and longitudinal pipe welds, nozzle-to-pipe welds and RPV nozzle-to-shell welds. Special probes designed to fulfill ...

1994-12-31

312

Application of probabilistic methods to validate NPP pipewhip impact simulations  

Energy Technology Data Exchange (ETDEWEB)

Piping in nuclear power plants is vital to the proper operation and safety of these facilities. To assure safety in the unlikely event of a pipe break, it is necessary to evaluate the consequences from the resulting whipping pipe on neighboring components and structures. Numerical simulations allow for rapid evaluation of these consequences. Before simulations can be accepted, however, the methodology and computer codes must be validated against experimental results. This paper uses a probabilistic approach to validate pipe whip simulations against limited experimental results. Probabilistic analysis software was developed and coupled to existing deterministic finite element software. An example of a whipping pipe impacting against a reinforced concrete slab was simulated. The described probabilistic approach was used to validate the numerical simulations. The conclusions obtained ...

2006-02-15

313

Peculiarities of crack propagation in laminated composite materials and their influence on resilience absorbed energy  

International Nuclear Information System (INIS)

Presented are the results of the investigation of the kinetics and micromechanism of the failure in impact bending of oriented-crystallized specimens having the eutectic composition Ni_3Al-Ni_3Nb and of the bimetal composed of 45 steel + M3 copper. The failure kinetics was studied by high-speed filming, whereas the fractures were studied by electron fractography. The particularities of the failure of the laminar-type composite materials were found. Analyzed was the effect of the kinetic factors and the mechanism of failure upon its energy consumption.

314

Experimental investigation of the length of a free diffusion jet of fuel gases diluted with inert gases  

Science.gov (United States)

Experimental investigation of the length of single burning jets of methane and hydrogen previously diluted with an inert gas (nitrogen or helium) was carried out. Efflux of fuel gases into the atmosphere occurred through cylindrical extension pieces 4 and 8 mm in diameter. The Reynolds numbers at the cut of a piece varied in the range from 400 to 12,000. A clearly defined dependence of the jet length on the quality of the added inert gas is obtained. The correlation of experimental data made it possible to recommend formulas for engineering calculations of free laminar and turbulent jets.

2010-05-01

315

Thermal release of volatile fission products from irradiated nuclear fuel  

International Nuclear Information System (INIS)

An effective procedure for removing _3H, Xe and Kr from irradiated fuels was demonstrated using Shippingport UO"2 fuel. The release characteristics of _3H, Kr, Xe, and I from irradiated nuclear fuel have been determined as a function of temperature and gaseous environment. Vacuum outgassing and a flowing gas stream have been used to vary the gaseous environment. Vacuum outgassing released about 99% of the _3H and 20% of both Kr and Xe within a 3 h at 1500_0C. Similar results were obtained using a carrier gas of He containing 6% H"2. However, a carrier gas containing only He resulted in the release of approximately 80% of the _3H and 99% of both Kr and Xe. These results indicate that the release of these volatile fission products from irradiated nuclear fuel is a function of the chemical composition of the gaseous environment. The rate of tritium release increased with increasing temperature (1100 to 1500_0C) and with the addition of hydrogen to the gas stream. ...

316

TRANSPORT CHARACTERISTICS OF REPRESENTATIVE DEBRIS IN A OPEN CHANNEL  

Energy Technology Data Exchange (ETDEWEB)

During LOCA(Loss of Coolant Accident), emergency core coolant supplements form a recirculation sump and cooled core and containment. When the double ended guillotine Break (DEGB) at the hot leg near steam generator, due to the jet impingement discharge flow, the debris could be potentially generated at pipe or wall nearby steam generator and be transported to the recirculation sump. Therefore, the debris could be accumulated and be clogged in the recirculation sump screen. If debris blocked the sump screen, the pressure drop increased at the screen so as to increase the pressure loss of ECCS (Emergency Core Cooling System) pump NPSH (Net positive suction head). It is potentially influenced to decrease the long-term cooling capability of the recirculation sump. The recirculation sump screen clogging accident has happened in BWR at 1990. Considering the important of safety, US NRC published Regulatory Guide 1.82 Rev.3 incorporating the R and D ...

2010-05-15

317

Oil shale, tar sand, coal research, advanced exploratory process technology jointly sponsored research. Quarterly technical progress report, April--June 1992  

Energy Technology Data Exchange (ETDEWEB)

Accomplishments for the quarter are presented for the following areas of research: oil shale, tar sand, coal, advanced exploratory process technology, and jointly sponsored research. Oil shale research includes; oil shale process studies, environmental base studies for oil shale, and miscellaneous basic concept studies. Tar sand research covers process development. Coal research includes; underground coal gasification, coal combustion, integrated coal processing concepts, and solid waste management. Advanced exploratory process technology includes; advanced process concepts, advanced mitigation concepts, and oil and gas technology. Jointly sponsored research includes: organic and inorganic hazardous waste stabilization; development and validation of a standard test method for sequential batch extraction fluid; operation and evaluation of the CO{sub 2} HUFF-N-PUFF Process; fly ash binder for unsurfaced road aggregates; solid state NMR analysis of Mesa Verde Group, Greater Green River ...

1992-12-01

318

Evaluation of Ordos Basin in China  

Energy Technology Data Exchange (ETDEWEB)

Ordos basin lies in the north-central China, in a compression tectonic regime, with an area of approximately 250,000 km{sup 2}, including several pay zones ranging from Cambrian to Jurassic. It is one of the earliest-formed marine to continental-superimposed basin in China, characterized by Proterozoic basin-marginal rifling and Lower-Paleozoic carbonate platform development followed by western thrusting and foreland depression during Mesozoic. It underwent several tectonic movements and is covered by several structural layers, with many play types developed, primarily thrust and anticlinal plays in the west, and differential compaction (river-channel sand lens) or drape as well as buried hill plays in the basin center and east. Ordos basin is a prolific gas basin with an estimated resource potential of gas 656,091 billion m{sup 3} in the Paleozoic strata and oil 2.0474 billion tons in the Mesozoic strata. In 1986, in the western part of the basin, the well Tian-1 on the Tianchi ...

1996-06-01

319

Thermally isolated pipeline  

Energy Technology Data Exchange (ETDEWEB)

The pipelines is provided for gases, particluarly helium, at temperature of about 1000/sup 0/C (pressure about 40 bar) and is used as the connection be tween a gas cooled high temperature reactor and a heat load. The pipe consists of a temperature-resistant inner tube, which is composed of several pipe sections, which are supported on ball bearings, and a gas tight pressurised outer tube. There are supports and insulation between the two tubes. The sub-claims concern fixing of and bearings for the pipe sections. The description is very detailed and supplemented by drawings.

1980-08-28

320

Parametric study of the amplification factor in the energy balance method  

Energy Technology Data Exchange (ETDEWEB)

This paper represents a parametric study of the amplification factor to account for rebound effects in the Energy Balance Method. Of the 66 distinct cases we chose for our parametric study, the amplification factor of 1.1 seems sufficient except in four borderline cases where the carbon steel pipes are small or have very small gaps between the pipes and the pipe whip restraints. We conclude that the amplification factor generally decreases as the parameters gap size, hinge-to-break distance and overhang increase.

1985-04-01

321

Installation of the natural gas network at Paray-Vieille Poste, France  

Energy Technology Data Exchange (ETDEWEB)

This paper summarizes the investigation of horizontal direction drilling and the subsequent experimental installation of a natural gas network in a suburb of Paris, France. Three aspects of drilling were studied prior to implementation: (1) reliability of the technique and quality of pipelaying to ensure long-term supply main operation; (2) ability to assess the successfulness of the work by assessing preliminary conditions; and (3) economonic viability. Measurement of tensile stress on polyethylene pipe during pulling and comparative accelerated aging tests on scratched pipe were performed. In the implementation phase, 300 meters of pipe were laid daily, by using three machines simultaneously, at a cost comparable to that of conventional techniques.

1996-08-01

322

Effects of postulated event devices on normal operation of piping systems in nuclear power plants. Technical report  

Energy Technology Data Exchange (ETDEWEB)

This report considers the effect of pipe-whip restraints and snubbers on the normal operation of piping systems in nuclear power plants. Also considered are the effect of these postulated event devices on reliability, economics, and the exposure of plant personnel to radiation. Field data were gathered from three nuclear power plants that had applied for Operating Licenses. Criteria, design philosophies, and data were obtained from the respective nuclear steam system suppliers, architects-engineers and utilities.

1981-05-01

323

Dynamic response of pipelines buried in back-filled trenches  

Energy Technology Data Exchange (ETDEWEB)

Dynamic response of pipelines buried in a back-filled rectangular trench in a semi-infinite medium has been investigated. The pipelines are modeled as long cylindrical shells of small thickness. By using the boundary integral representation and finite element method, we have studied the three-dimensional response to account for either pane P or SV wave incident at an arbitrary angle to the pipe-axis. In this paper numerical results are presented for the normal displacements, displacements along pipe-axis, and the hoop stresses in the pipe wall. It is shown that the response depends critically on the back-filled material as well as on the directions of propagation of the incident waves.

1991-08-01

324

Virtual Stove Pipes - NASA  

Science.gov (United States)

Orchestration Layer. Service Delivery . Datacenter. Infrastructure. Systems call API. E2E automated. Automate service-levels. Analyze & ...

325

Unclas - NASA Technical Report Server (NTRS)  

Science.gov (United States)

COMPUTER PROGRAM GRADE. FOR DESIGN AND ANALYSIS. OF GRADED-POROSITY HEAT-PIPE. WICKS. Contract No. NAS 2-8310. August 1974. Prepared by. J. E. Eninger ...

326

Systems analysis programs for hands-on integrated reliability evaluations (SAPHIRE) Version 5.0. Fault tree, event tree, and piping & instrumentation diagram (FEP) editors reference manual: Volume 7  

Energy Technology Data Exchange (ETDEWEB)

The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) refers to a set of several microcomputer programs that were developed to create and analyze probabilistic risk assessments (PRAs), primarily for nuclear power plants. The Fault Tree, Event Tree, and Piping and Instrumentation Diagram (FEP) editors allow the user to graphically build and edit fault trees, and event trees, and piping and instrumentation diagrams (P and IDs). The software is designed to enable the independent use of the graphical-based editors found in the Integrated Reliability and Risk Assessment System (IRRAS). FEP is comprised of three separate editors (Fault Tree, Event Tree, and Piping and Instrumentation Diagram) and a utility module. This reference manual provides a screen-by-screen guide of the entire FEP System.

1994-07-01

328

Splinter Protection for Airbase Firefighting Resources  

Science.gov (United States)

... 36 7 Corrugated Steel Pipe Concept Layout--Elevation ..... 37 viii ... revetment. 3. Land Use ... Corner modules and capping blocks are available. ...

1989-12-01

329

Safety of pipe whip restraints  

International Nuclear Information System (INIS)

Pipe whip restraints are used in nuclear power plants in order to limit the consequences of ruptured pipe whip effects and are thus an important part of the plant safety concept. The design of these devices is based on the choice of adequate construction and computational analysis supported by experimental investigation. Pipe whip restraints should, by means of deforming components, be able to absorb the energy of a ruptured pipe accelerated by the fluid reaction force. Since the elastic deformation of the restraint material is not sufficient for this purpose, or would result in excessive anchor loads, pipe whip restraints must generally be designed to work in the plastic range. Two types of restraints are presented in this paper, including the description of their mode of operation, design and computation. A comparison and critical evaluation of the calculation methods presently ...

330

Revisited the mathematical derivation wall thickness measurement of pipe for radiography  

Energy Technology Data Exchange (ETDEWEB)

Wall thickness measurement of pipe is very important of the structural integrity of the industrial plant. However, the radiography method has an advantage because the ability of penetrating the insulated pipe. This will have economic benefit for industry. Moreover, the era of digital radiography has more advantages because the speed of radiographic work, less exposure time and no chemical used for film development. Either the conventional radiography or digital radiology, the wall thickness measurement is using the tangential radiography technique (TRT). In case, of a large diameter, pipe (more than inches) the determination maximum penetration wall thickness must be taken into the consideration. This paper is revisited the mathematical derivation of the determination of wall thickness measurement based on tangential radiography technique (TRT). The mathematical approach used in this derivation is the Pythagoras theorem and ...

2007-07-01

331

Pipe Freeze Prevention for Passive Solar Water Heaters Using a Room-Air Natural Convection Loop: Preprint  

Energy Technology Data Exchange (ETDEWEB)

Conference paper regarding research in the use of freeze prevention for passive solar domestic water heating systems.

2006-05-01

332

Participative risk management in the construction of onshore pipelines  

Energy Technology Data Exchange (ETDEWEB)

This paper described a risk control management tool that has been developed by Petrobras Petroleo, the largest Brazilian oil company and one of the world's leading oil companies. The system covers health, safety and environmental (HSE) issues regarding pipeline construction projects. The limitations of traditional safety management systems for coping with the critical problems related to environmental safety issues were discussed. In particular, this paper described how the HSE tool evaluates the risks resulting from the following aspects of onshore pipeline construction and assembly: establishing right-of-way and route locations, transporting pipe, developing the construction site, opening the trench, pipe laying, pipe bending, concrete external coating, welding, external anticorrosive coatings, pipe placement backfilling, hydrostatic testing, maintenance operations, and pipeline ...

2000-07-01

333

Offshore drilling rig with enclosed work area  

Energy Technology Data Exchange (ETDEWEB)

In order to improve the working conditions for the operators of drilling rigs, the work area for handling of pipes and tubes is arranged on a main deck convered by a drill deck, which has openings closable by hatch cover panels. The derrick is enclosed in a cover, from which tunnels extend out over the drill deck and comprises lifting means for handling of pipes and tubes between the decks. The tunnels are connected to the cover of the derrick by raised enclosures permitting the swinging of pipes from a horizontal position in the tunnel to a vertical position in the derrick, and vice versa. There is a door, at least at one of the enclosures, permitting handling of especially long objects. Basically, the handling of pipes and tubes can be performed within areas fully protected from the weather.

1987-12-01

334

Measurement of induced radioactivity in materials found around a neutron generator  

Science.gov (United States)

The induced radioactivity in the construction materials of a Cockcroft-- Walton type neutron generator was measured. Major activation products (/sup 24/ Na, /sup 28/Al, /sup 56/Mn, /sup 64/Cu, /sup 65/Ni, /sup 69m/Zn, /sup 88/Rb /sup 91/Sr /sup 101/Mo, /sup 187/W/ and resulting doses are tabulated. Results show that the highest gamma activities would be observed in the fluorescent bulbs, copper pipe, aluminum lattice rod, and the aluminum pipe clamp. Thermoluminescent dosimeter readings yield the highest doses for the copper pipe tee, copper pipe, and aluminum lattice rod. Results of measuremerts of the neutron and gamma dose profiles of the facility are shown. However the indication is clearly that the tritium target, compared to other components, is the major source of radiation both during and after shutdown. (UK)

1974-01-01

335

Long-term storage of solar heat  

Energy Technology Data Exchange (ETDEWEB)

Stochastic models for the simulation of global radiation are discussed. Thermal transients in the ground are analyzed. The performance of buried-pipe storage and a space heating system with long-term storage is described.

1981-06-01

336

Light weight underground pipe or cable installing device  

Energy Technology Data Exchange (ETDEWEB)

This invention pertains to a light weight underground pipe or cable installing device adapted for use in a narrow and deep operating trench. More particularly this underground pipe installing device employs a pair of laterally movable gates positioned adjacent the bottom of the operating trench where the earth is more solid to securely clamp the device in the operating trench to enable it to withstand the forces exerted as the actuating rod is forced through the earth from the so-called operating trench to the target trench. To accommodate the laterally movable gates positioned adjacent the bottom of the narrow pipe installing device, a pair of top operated double-acting rod clamping jaws, operated by a hydraulic cylinder positioned above the actuating rod are employed.

1985-01-08

338

Foreign Object Impact Design Criteria. Volume 2  

Science.gov (United States)

... This Level 2 analysis will be somewhat less detailed, but experience in other fields including pipe whip 4 , locomotive dynamics, and nuclear fuel ...

1982-02-01

339

Electrical Transmission Line Diametrical Retention Mechanism  

Science.gov (United States)

The invention is a mechanism for retaining an electrical transmission line. In one embodiment of the invention it is a system for retaining an electrical transmission line within downhole components. The invention allows a transmission line to be attached to the internal diameter of drilling components that have a substantially uniform drilling diameter. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string, drill collars, heavy weight drill pipe, and jars. The system also includes a coaxial cable running between the first and second end of a drill pipe, the coaxial cable having a conductive tube and a conductive core within it. The invention allows the electrical transmission line to withstand the tension and compression of drill pipe during routine drilling cycles.

2006-01-03

340

DEPLOYABLE HEAT PDPE RADUATOR - NASA Technical Report Server (NTRS)  

Science.gov (United States)

Eninger, J. E.: "Menisci Coalesence as a Mechanism for Venting Noncondensible. Gas From Heat-Pipe Arteries", AIAA Paper No. 74-748. ...

341

Apparatus for measuring the decontamination factor of a multiple filter air-cleaning system  

Energy Technology Data Exchange (ETDEWEB)

An apparatus for measuring the overall decontamination factors of first and second filters located in a plenum. The first filter separates the plenum's upstream and intermediate chambers. The second filter separates the plenum's intermediate and downstream chambers. The apparatus comprises an aerosol generator that generates a challenge aerosol. An upstream collector collects unfiltered aerosol which is piped to first and second dilution stages and then to a laser aerosol spectrometer. An intermediate collector collects challenge aerosol that penetrates the first filter. The filtered aerosol is piped to the first dilution stage, diluted, and then piped to the laser aerosol spectrometer which detects single particles. A downstream collector collects challenge aerosol that penetrates both filters. The twice-filtered aerosol is piped to the aerosol spectrometer. A pump and several valves ...

1985-07-03

342

Analysis of postulated FFTF pipe ruptures  

International Nuclear Information System (INIS)

A detailed assessment of the FFTF Primary Heat Transport System (PHTS) piping has led to the conclusion that the integrity of the piping is assured such that there is no realistic potential for a rupture. Nevertheless, consistent with the practice of showing design margins even for hypothetical events, a spectrum of postulated PHTS ruptures has been analyzed. The analyses showed that upstream of the reactor vessel inlet downcomer, rupture areas of any size including a double-ended rupture could be tolerated with no core coolant boiling. At the most limiting location, the reactor inlet nozzle, rupture areas of 75 in."2 and 55 in."2 could be tolerated for three-loop and two-loop operation, respectively. This paper will present the following: (1) the criterion with which consequences of postulated pipe ruptures are compared; (2) the general transient response of the FFTF to postulated ruptures; and (3) the acceptable rupture ...

343

A heating surface  

Energy Technology Data Exchange (ETDEWEB)

A design is proposed for forming the rear screen of a chamber firebox at the point of aerodynamic projection and a design for attaching the pipes of the aerodynamic projection using girders linked with the screen by hinges and movable connections.

1982-01-01

345

Flow deflector for nuclear fuel element assemblies  

International Nuclear Information System (INIS)

... coolants departure nucleate boiling fluid flow fluidic control devices fuel

346

Upgrading the ampacity of HPFF pipe-type cable circuits  

Energy Technology Data Exchange (ETDEWEB)

The upgrading of several 69 kV pipe-type cable feeders on the Potomac Electric Power Company (PEPCo) transmission cable system is discussed. The methods used for the ampacity calculation are described. The fluid circulation approach required to meet the feeder emergency load requirements are discussed. For the feeders that were in service for approximately 40 years, a system life evaluation was performed.

1994-12-31

347

Probabilistic leak before break evaluation of straight pipes of primary heat transport piping of Tarapur-3 and 4 NPP  

International Nuclear Information System (INIS)

Piping systems transporting high-pressure fluid will release a large amount of energy, leading to whipping of the broken pipe as well as impingement of the ejecting fluids on adjacent structures if they fracture unstably. Postulation of such an event in design of piping systems in nuclear power plants often requires various counter measures such as installation of pipe whip restraints or jet impingement shields to prevent such damage. One of the approaches to justify exclusion of unstable fracture from the design conditions is leak-before-break (LBB) analysis. In order to demonstrate LBB behavior, it is necessary to prove that in the presence of a part-through wall flaw in the pipe, this flaw will not grow through the wall under fatigue loading and is stable (level 2 LBB) and that the leak of fluid through the penetration is detected by leak detection systems before unstable ...

2006-11-01

348

Lead exposure via drinking water - unnecessary and avoidable  

International Nuclear Information System (INIS)

Despite successful reduction of the general lead exposure, this heavy metal is still a matter of public concern due to the fact that associations with intellectual impairment or delayed puberty are found to correlate with very low lead blood concentrations. Lead in tap water is still an important contribution to lead exposure which may cause health risk for infants. Therefore, lead pipes should be completely sanitated by exchange against pipes made from more healthy materials. (orig.)

349

Evaluation of 230 kV HPFF pipe-type cable with wrinkled and creased insulating tapes  

Energy Technology Data Exchange (ETDEWEB)

Severe collapse wrinkles and circumferential creases were discovered in the cellulose paper insulating tapes of a newly installed IIPFF pipe-type cable during splicing and terminating. An evaluation program was developed to assess the electrical and mechanical integrity of the cable having wrinkled and creased insulating tapes. The test results indicated that the cable would perform satisfactorily in service.

1995-01-01

350

Assessment of pipeline integrity and associated hazards  

Energy Technology Data Exchange (ETDEWEB)

This paper outlines aspects of the procedures adopted within Nuclear Electric plc for the assessment of Leak before Break arguments and the consequences arising from leakage and/or pipe failure. Only new aspects are considered such as creep, leakage, temperature and over pressure assessments and pipe whip. 7 refs.

1995-12-31

351

Analysis of chlorinated polyvinyl chloride pipe burst problems :Vasquez residence system inspection.  

Energy Technology Data Exchange (ETDEWEB)

This report documents the investigation regarding the failure of CPVC piping that was used to connect a solar hot water system to standard plumbing in a home. Details of the failure are described along with numerous pictures and diagrams. A potential failure mechanism is described and recommendations are outlined to prevent such a failure.

2005-10-01

352

Probability of failure in BWR reactor coolant piping: Guillotine break indirectly induced by earthquakes  

Energy Technology Data Exchange (ETDEWEB)

The requirements to design nuclear power plants for the effects of an instantaneous double-ended guillotine break (DEGB) of the reactor coolant piping have led to excessive design costs, interference with normal plant operation and maintenance, and unnecessary radiation exposure of plant maintenance personnel. This report describes an aspect of the NRC/Lawrence Livermore National laboratory-sponsored research program aimed at investigating whether the probability of DEGB in Reactor Coolant Loop Piping of nuclear power plants is acceptably small such that the requirements to design for the DEGB effects (e.g., provision of pipe whip restraints) may be removed. This study estimates the probability of indirect DEGB in Reactor Coolant piping as a consequence of seismic-induced structural failures within the containment of the GE supplied boiling water reactor at the Brunswick nuclear power plant. The median ...

1986-12-01

353

FEM Analysis and Measurement of Residual Stress by Neutron Diffraction on the Dissimilar Overlay Weld Pipe  

International Nuclear Information System (INIS)

Much research has been done to estimate the residual stress on a dissimilar metal weld. There are many methods to estimate the weld residual stress and FEM (Finite Element Method) is generally used due to the advantage of the parametric study. And the X-ray method and a Hole Drilling technique for an experimental method are also usually used. The aim of this paper is to develop the appropriate FEM model to estimate the residual stresses of the dissimilar overlay weld pipe. For this, firstly, the specimen of the dissimilar overlay weld pipe was manufactured. The SA 508 Gr3 nozzle, the SA 182 safe end and SA376 pipe were welded by the Alloy 182. And the overlay weld by the Alloy 52M was performed. The residual stress of this specimen was measured by using the Neutron Diffraction device in the HANARO (High-flux Advanced Neutron Application ReactOr) research reactor, KAERI (Korea Atomic Energy Research Institute). Secondly, FEM ...

2010-10-01

354

Cold bending of 34'' OD API 5L X80 pipes; Curvamento a frio de tubos API 5L X80 de 34'' de diametro  

Energy Technology Data Exchange (ETDEWEB)

A key factor that demands special attention in the pipeline construction is the cold bending process, since 30 to 40% of the pipes use this process in the field. This study aimed to evaluate the X80 cold bending operational parameters, in order make viable the use of this process in the installation of future onshore pipelines. Three 34''OD x 0,750'' pipes were bended. The bending was conducted using a hydraulic equipment with application of equally spaced punches, recording the correspondent angles related to the elastic and plastic deformations in order to assess the spring-back effect and performing dimensional inspection. Samples from pipe and the weld were subjected to mechanical and metallographic tests. It was possible to obtain a 19 deg curve and 27D radius without presenting any evidence of wrinkles, out of roundness or any type of mechanical damage. After analysis, all criteria ...

2008-07-01

355

Calculating ac/dc resistance ratios for high-pressure oil-filled cable Designs. Volume 1. Designer's guide. Final report  

Energy Technology Data Exchange (ETDEWEB)

Using electromatic field theory, a new method is developed for calculating alternating current in power cables installed in pipes of carbon steel (magnetic pipes). The technique for evaluating these losses is based on the method of images which replaces complicated distribution of currents in the system with a sequence of thin conductors. The method not only gives a mathematical framework for the solution of alternating current losses, but it also gives the underlying physical picture of effects contributing to these losses. Skin effect, proximity effect and losses due to the pipe are calculated separately. For the first time, the increase of losses in the conductors, when the cables are placed in a magetic pipe, are analyzed mathematically. Good agreement is obtained between the result of calculations and the experimentally determined ac-dc resistance ratios for pipe-type cables ...

1985-04-01

356

API 5L X80M OD 34 inches cold bending  

Energy Technology Data Exchange (ETDEWEB)

One of the main factors that require special attention in a pipeline construction is the cold bending process, once depending on the region that the line will be installed the number of bends may achieve 75%, as it was observed in some areas during Campinas-Rio pipeline construction. A study was carried out to evaluate the X80 cold bending operational parameters in order to make viable the use of high strength pipes in the construction of onshore pipelines. For this analysis three pipes of 34 inches x 0.750 inches had been cold bended, the operation was carried out using a hydraulic equipment with punches applications along the pipe, recording the correspondent angles related to the elastic and plastic deformations in order to assess the material spring-back. After the bending process, samples of the weld, extrados and intrados were subjected to mechanical and metallographic tests, as well as performed dimensional ...

2009-07-01

357

A high accuracy ultrasonic measurement method for nondestructive evaluation of residual stress in welded pipings  

Energy Technology Data Exchange (ETDEWEB)

Today`s nuclear power plants are marked by increasing needs for non-destructive inspection techniques in preventive maintenance programs. Additionally, it is becoming more important to evaluate residual stress which may be a key parameter for crack propagations in welded pipings. The authors have developed an ultrasonic velocity measurement method which obtains ultrasonic velocity changes by residual stress with a high accuracy. The ultrasonic velocity measurement is composed of three procedures. They are as follows. (1) Highly accurate propagation time measurements; (2) Pipe thickness correction; (3) Residual stress evaluation. The ultrasonic velocity measurements have been applied to the residual stress evaluation of carbon steel welded pipings. Destructive testing using stress strain gauges was done after the ultrasonic non-destructive evaluation of the residual stress. The experimental results verified that residual ...

1995-08-01

358

Multiphase flow calculation software  

Energy Technology Data Exchange (ETDEWEB)

Multiphase flow calculation software and computer-readable media carrying computer executable instructions for calculating liquid and gas phase mass flow rates of high void fraction multiphase flows. The multiphase flow calculation software employs various given, or experimentally determined, parameters in conjunction with a plurality of pressure differentials of a multiphase flow, preferably supplied by a differential pressure flowmeter or the like, to determine liquid and gas phase mass flow rates of the high void fraction multiphase flows. Embodiments of the multiphase flow calculation software are suitable for use in a variety of applications, including real-time management and control of an object system.

2003-04-15

359

Hydrodynamics of swirling flow in a circular tube with sudden increase in cross-section and of the flow through a Borda mouthpiece  

Energy Technology Data Exchange (ETDEWEB)

By applying the mass, momentum, and angular momentum conservation laws and the maximum flow rate principle to swirling, effectively inviscid, incompressible flows in a circular tube with a sudden expansion and the direct-flow and reversed-flow Borda mouthpieces the dependence of the flow rate coefficient and mechanical energy losses on the radius ratio and nondimensional circulation is obtained. Several calculating approaches with potential and helical motion are introduced and investigated. In the case of helical motion, as the swirl decreases the axial core of the flow is found to close with a sudden change of the flow parameters.

1994-11-01

360

Wind Tunnel Flow Quality and Data Accuracy Requirements  

Science.gov (United States)

... tests, one often encounters, for instance, separated flows with large ... It is suspected that the flow-quality criteria given in AGARD Report No. ...

1982-11-01

361

Simulation of ground-water flow in the basin-fill aquifer of the Tularosa Basin, south-central New Mexico, ...  

Science.gov (United States)

... percent by interbasin ground-water flow into the Hueco Bolson, and 2 percent by flow into creeks and ... ...

362

RESEARCH ON FLOW SEPARATION IN WESTERN EUROPE  

Science.gov (United States)

... Separation," AGARD,Rept 272, April 1960, ... Leading Edge Effect on Supersonic Boundary Layer Flow." ... of Gas Injection in Separated Flows." TCEA, ...

1963-07-01

363

Perfect and Incompressible Fluid Flow in Turbomachines.  

Science.gov (United States)

A method for calculating flow through an airfoil cascade drawn on a surface of revolution is discussed. The three-dimensional flow was assumed to be represented by part-channels of varying width. The basic equations are the equation of continuity and the ...

1974-01-01

364

Large Eddy Simulation of Supersonic Turbulent Flow in ...  

Science.gov (United States)

... AGARD AR-319, Volume 2. Knight, D., Zhou ... a Turbulent Boundary Layer in a Supersonic Flow. ... of Development of Separated Flows in Compression ...

2001-08-01

365

Free Shear Layers, Base Pressure and Bluff-Body Drag  

Science.gov (United States)

... In: Separated Flows, AGARD CP No. ... on thin wings in two-dimensional incompressible flow. ... fields in the region of separating and reattaching flows. ...

1993-12-10

366

Control of Flow Separation Using Adaptive Airfoils  

Science.gov (United States)

... been demonstrated in steady compressible flows. ... steady Compressible Flow on an Oscillating Airfoil ... of Oscillating Airfoils", AGARD-CP-552, Aug. ...

1997-01-01

367

Calculation and Measurement of Transonic Flows over ...  

Science.gov (United States)

... including those with rear separation, ... flows ibout airfoils." AIAA Paper 'Jo 97-0419, 1987). ... "Effects of streamline curvature on turbulent flow." AGARD ...

1988-10-01

368

Asymmetric Vortex Flow Over Circular Cones  

Science.gov (United States)

... Calculations of asymmetric separated flow past circular ... in Missile Aerodynamics, AGARD CP 336 ... three-dimensional vortex flows in aerodynamics. ...

1991-03-01

369

Application of Synthetic Jets to Reduce Stator Flow Separation in a ...  

Science.gov (United States)

Surface pressure measurements at mid span indicate that flow separation begins near ..... Turbomachinery Flows, AGARD Propulsion Energetics Panel, 1998. ...

370

A Simple Model of Vortex Flow Past a Slender Elliptic Cone at ...  

Science.gov (United States)

... Calculations of asymmetric separated flow past circular ... in Missile Aerodynamics, AGARD-CP-336 ... Marconi Asymmetric separated flows about sharp ...

1990-09-01

371

Two-phase flow studies  

Energy Technology Data Exchange (ETDEWEB)

The two-phase flow program is directed at understanding the hydrodynamics of two-phase flows. The two-phase flow regime is characterized by a series of flow patterns that are designated as bubble, slug, churn, and annular flow. Churn flow has received very little scientific attention. This lack of attention cannot be justified because calculations predict that the churn flow pattern will exist over a substantial portion of the two-phase flow zone in producing geothermal wells. The University of Houston is experimentally investigating the dynamics of churn flow and is measuring the holdup over the full range of flow space for which churn flow exists. These experiments are being conducted in an air/water vertical two-phase flow loop. Brown ...

1983-12-01

372

The Second International Piping Integrity Research Group (IPIRG-2) program. Final report, October 1991--April 1996  

Energy Technology Data Exchange (ETDEWEB)

The IPIRG-2 program was an international group program managed by the US NRC and funded by organizations from 15 nations. The emphasis of the IPIRG-2 program was the development of data to verify fracture analyses for cracked pipes and fittings subjected to dynamic/cyclic load histories typical of seismic events. The scope included: (1) the study of more complex dynamic/cyclic load histories, i.e., multi-frequency, variable amplitude, simulated seismic excitations, than those considered in the IPIRG-1 program, (2) crack sizes more typical of those considered in Leak-Before-Break (LBB) and in-service flaw evaluations, (3) through-wall-cracked pipe experiments which can be used to validate LBB-type fracture analyses, (4) cracks in and around pipe fittings, such as elbows, and (5) laboratory specimen and separate effect pipe experiments to provide better insight into the effects of dynamic and cyclic load ...

1997-03-01

373

Microbiologically influenced corrosion of carbon and stainless steel pipes; Mikrobiologisch beeinflusste Korrosion an Rohrleitungen aus unlegierten und hochlegierten nichtrostenden Staehlen  

Energy Technology Data Exchange (ETDEWEB)

About ten years ago microbiologically influenced corrosion manifested on stainless steel pipes used with river water for cooling a chemical plant. The pipe material was similar to Type 316 L. After only six weeks of operation pinhole leaks occurred nearly simultaneously at several welded joints of the pipe. The material degradation was simulated in laboratory and field corrosion tests. Microbiologically influenced corrosion failures also appeared on the pipes of a tubular heat exchanger of duplex steel Type 31803 and on carbon and stainless steel pipes in industrial waste water purification plants after these plants had been modernized with a biological purification unit. The basics of microbiologically influenced corrosion phenomena and typical corrosion failures of pipes will be described. (orig.) [German] Vor etwa zehn Jahren sind in einer neu errichteten ...

1999-09-01

374

Analysis of cost-effective pipe insulation requirements  

Energy Technology Data Exchange (ETDEWEB)

The proposed ASHRAE/IES Standard 90.1-1989R contains updated requirements for pipe insulation thicknesses developed on the basis of technical and economic principles. These requirements were determined based on computer simulations of the annual energy loss through the insulation, first cost assumptions for the insulation, and economic assumptions of discount rate and energy escalation rate. In later work, the same tools were used to analyze the sensitivity of the cost-effective insulation level for piping insulation to variations in operating hours, ambient temperature, fluid temperature, and economic assumptions. These analyses were carried out using cost data for pipe insulation averaged across several sources. The results of the sensitivity study showed that system operating hours is a critical parameter in determining the cost-effective pipe insulation thicknesses. Although there is a lack of ...

1997-09-01

375

Morphology of modified starches prepared by different methods  

British Library Electronic Table of Contents (United Kingdom)

Morphologies of modified starches prepared using different methods were examined by scanning electron microscopy (SEM). These SEM micrographs provide the following results. To begin with, starch granules underwent a series of changes which resulted in the morphology of modified starch quite different from the native starch with different the methods during the process of modification. For example, hollows emerge on the granules of maltodextrin with low value of dextrose equivalent (DE) prepared by means of spray-drying, but they fell to pieces with the increasing value of DE. The granules of pregelatinized starches manufactured with extrusion technology also showed irregular stone shapes and holes within them while those produced by means of drum-drying presented irregular laminar structur...

2010-01-01

376

Histologie et mode de croissance des premaxillaires hyperplasiques du Ziphiidae fossile Aporotus recurvirostris (Mammalia, Cetacea, Odontoceti)  

British Library Electronic Table of Contents (United Kingdom)

Beaked whales (Ziphiidae) often show highly specialized features, involving bone morphology or structure, in the rostral region of their skulls. Previous studies revealed an extremely derived and peculiar histological structure in the rostrum of the extant Mesoplodon densirostris. In order to assess if this structure is a general feature of ziphiids, the swollen premaxillae of Aporotus recurvirostris, a Miocene species from the North Sea, were studied histologically. These bones are pachyostotic and strongly osteosclerotic. However, their structural organization is entirely different from that of M. densirostris rostrum: they are basically made of a non-remodeled, laminar tissue that was cyclically deposited by the periosteum. As compared to the generalized structure of the premaxillae of ...

2011-01-01

377

Absorption of carbonyl sulfide in aqueous methyldiethanolamine  

Energy Technology Data Exchange (ETDEWEB)

The absorption of carbonyl sulfide in aqueous methyldiethanolamine (MDEA) was studied over a range of temperatures and MDEA concentrations. MDEA is commonly used for selective absorption of hydrogen sulfide in the presence of carbon dioxide. However, sulfur in the form of COS may also be present and it is necessary that estimates of absorption rates of this compound be made. The objective of this study is to determine the physiochemical properties needed to predict COS absorption rates in aqueous MDEA. Free gas solubility and the diffusivity of COS in MDEA solutions were measured over the temperature range 15 to 40{sup 0}C for MDEA concentrations up to 30 weight per cent using the nitrous oxide analogy method. Solubilities were measured volumetrically in an equilibrium cell and diffusivities were measured using a laminar liquid jet absorber. The kinetics of the reaction between COS and MDEA were studied by measuring absorption rates in a single wetted-sphere ...

1988-01-01

385

Structural analysis and stress evaluation system for steel structures: ADAMS  

Energy Technology Data Exchange (ETDEWEB)

In order to perform the structural analysis and stress evaluation for frame structures in the nuclear power plants, ADAMS (AIJ Design Analysis and Modules System) has been developed by the addition of the following functions to the ICES-STRUDL system. 1. Load combination and stress evaluation on the basis of specifications for designing steel structure (issued by the Architecture Institute of Japan). 2. Combination of load and stress evaluation of piping support on the basis of the regulations of Ministry of International Trade and Industry. 3. Addition of other functions than that described above. ADAMS enables structural analysis and stress evaluation exactly and efficiently not only for a large scale structure such as the pipe whip protection structure installed inside of the primary containment vessel for many loading cases but also for a large number of structures such as piping support. This system can be applied not ...

1980-11-01

386

Proterozoic kimberlites and lamproites and a preliminary age for the Argyle lamproite pipe, Western Australia  

International Nuclear Information System (INIS)

The Argyle pipe occurring in the East Kimberley Province of Western Australia is a unique, highly-diamondiferous lamproite. Although it resembles other lamproites located in the West Kimberley Province with respect to its setting, structure, petrography and geochemistry, it is probably Proterozoic in age and hence substantially older than Tertiary occurrences of the West Kimberley Province. Rb-Sr measurements on whole rock and phlogopite samples from magmatic olivine-phlogopite lamproite, reveals a two point model age of 1126 +- 9 Ma for the Argyle pipe. This age is consistent with ages of other, similar volcanic igneous rocks occurring in several localities worldwide. The widespread occurrence of Proterozoic kimberlites and lamproites suggests that this was an important period of worldwide alkalic intrusive activity.

387

Instrumented model pile tests on sand plugs  

Energy Technology Data Exchange (ETDEWEB)

0pen ended piles develop internal frictional resistance between the internal soil plug end the pile wall during axial loading. Current pipe pile design practice assumes that the ultimate internal skin friction is of the same order of magnitude as the outer skin friction. This paper describes a series of laboratory pile load tests on instrumented model pipe piles, designed to investigate the development of plug stresses and skin friction along the plug length during pile loading. The piles contain sand columns of various relative densities and of different heights. The soil plugs are loaded to failure under fully drained conditions. The test data indicate that internal skin friction in sand can be substantially higher than assumed in conventional design practice. This finding could lead to significant economical savings on future pipe pile foundations in sand.

1995-12-31

388

Inspection pig for gas pipeline  

Energy Technology Data Exchange (ETDEWEB)

The ultrasonic inspection pig system was described as being under development. This system was said to adopt the unique wheel type ultrasonic sensor which does not need couplant. This pig was designed to detect external corrosion in long-distance pipelines without interruption of the gas service. The wall-thickness measurement performance test and the travel performance test of the inspection pig in the test line confirmed that these performances satisfied the development specifications. However, the effect induced by the inner surface properties of the pipe and the influence of the pipe`s performance over long distances and for a long period of time still needed to be verified in an actual gas pipeline, and while the pipeline was actually in service. Improvements to the prototype model of the inspection pig were expected to include combinations of inspection pigs, with increases in battery and memory capacities to permit them to cope with in ...

1992-12-31

389

Evaluation of improvements in the installation of rural underground transmission lines: Final report  

Energy Technology Data Exchange (ETDEWEB)

This report presents the results of an investigation into currently used methods for installation of underground high voltage power transmission cable, and offers recommendations for potentially improving these methods. Suggested enhancements cover the emplacement of both high pressure oil filled (HPOPT) pipe type and self contained oil filled (SCOF) cable systems. Cost comparisons of conventionally installed cable systems versus systems using proposed techniques and equipment are developed for a specific site selected for study. The report also documents the test results of laboratory experiments conducted to demonstrate the feasibility of using interference fit pipe couplings in place of welded pipe joints. 10 refs., 31 figs., 15 tabs.

1987-10-01

390

Theoretical and Experimental Investigation of Flamespreading ...  

Science.gov (United States)

... CHANNELS, TWO PHASE FLOW, WAVES, IGNITERS, GAS FLOW, HOWITZERS, CARTRIDGE CASES, COMBUSTIBLE CARTRIDGE CASES. ...

1986-02-01

391

Special Course on Three-Dimensional Supersonic ...  

Science.gov (United States)

... Dynamics Panel Executive AGARD 7 rue ... 4 AXIAL FLOW IN CORNERS AT SUPERSONIC ... AND HYPERSONIC FLOWS INCLUDING SEPARATION ...

1990-01-01

393

Diaphragm Rupture Effects on an Expanding Flow in a Tube.  

Science.gov (United States)

... The fundamental problem of diaphragm rupture was studied experimentally to determine the effects on an expanding flow in an evacuated tube. ...

1972-08-01

394

Application of neutron radiography to visualization of multiphase flows  

Energy Technology Data Exchange (ETDEWEB)

Visualizations by real-time neutron radiography are demonstrated of various flow patterns of nitrogen gas-water two-phase flow in a stainless-steel tube, water inverted annular flow in a stainless-steel tube, flashing flow in an aluminium nozzle and fluidized bed in aluminium tube and vessels. Photographs every 1/60 s are presented by an image processing method to show the dynamic behaviours of the various flow patterns. It is shown that this visualization method can be applied efficiently to multiphase flow researches and will be applicable to multiphase flows in industrial machines. (author).

1990-04-01

395

Application of neutron radiography to visualization of multiphase flows  

International Nuclear Information System (INIS)

Visualizations by real-time neutron radiography are demonstrated of various flow patterns of nitrogen gas-water two-phase flow in a stainless-steel tube, water inverted annular flow in a stainless-steel tube, flashing flow in an aluminium nozzle and fluidized bed in aluminium tube and vessels. Photographs every 1/60 s are presented by an image processing method to show the dynamic behaviours of the various flow patterns. It is shown that this visualization method can be applied efficiently to multiphase flow researches and will be applicable to multiphase flows in industrial machines. (author).

1990-01-01

396

Interfacial Area and Interfacial Transfer in Two-Phase Flow Systems (Volume IV. Chapters 15-19)  

Energy Technology Data Exchange (ETDEWEB)

Experiments were performed on horizontal air-water bubbly two-phase flow, axial flow, stratified wavy flow, and annular flow. Theoretical studies were also undertaken on interfacial parameters for a horizontal two-phase flow.

2003-03-15

397

Investigation of large amplitude stratified waves in a CANDU-type 37 rod nuclear fuel channel by a real-time neutron radiography technique  

Energy Technology Data Exchange (ETDEWEB)

A Real-Time Neutron Radiography (RTNR) system is used to determine two-phase flow parameters for a horizontal co-current two-phase flow channel with a CANDU-type 37 rod bundle. Image processing techniques are applied to visualize the two-phase flow, and to determine flow regime, cross-sectional averaged void fraction, time averaged void fraction, and void distribution. The experimentally determined flow regime map disagrees with existing flow regime models developed for the CANDU-type rod bundles. A new flow regime is observed and designated Large Amplitude Stratified Wavy flow. The results show that the LASW flow regime may be due to a combination of undeveloped flow phenomena, boundary conditions, and circumferential cross flow occurring in the bundle. The ...

1997-12-31

398

Investigation of large amplitude stratified waves in a CANDU-type 37 rod nuclear fuel channel by a real-time neutron radiography technique  

Energy Technology Data Exchange (ETDEWEB)

A real-time neutron radiography (RTNR) system is used to determine two-phase flow parameters for a horizontal co-current two-phase flow channel with a cylindrical 37 rod bundle. Image processing techniques are applied to visualize the two-phase flow, and to determine flow regime, cross-sectional averaged void fraction, time averaged void fraction, and void distribution. The experimentally determined flow regime map disagrees with existing flow regime models developed for the cylindrical rod bundles. A new flow regime is observed and designated large amplitude stratified wavy (LASW) flow. The results show that the LASW flow regime may be due to a combination of undeveloped flow phenomena, boundary conditions, and circumferential cross flow occuring in the ...

2000-08-01

399

Investigation of large amplitude stratified waves in a CANDU-type 37 rod nuclear fuel channel by a real-time neutron radiography technique  

International Nuclear Information System (INIS)

A Real-Time Neutron Radiography (RTNR) system is used to determine two-phase flow parameters for a horizontal co-current two-phase flow channel with a CANDU-type 37 rod bundle. Image processing techniques are applied to visualize the two-phase flow, and to determine flow regime, cross-sectional averaged void fraction, time averaged void fraction, and void distribution. The experimentally determined flow regime map disagrees with existing flow regime models developed for the CANDU-type rod bundles. A new flow regime is observed and designated Large Amplitude Stratified Wavy flow. The results show that the LASW flow regime may be due to a combination of undeveloped flow phenomena, boundary conditions, and circumferential cross flow occurring in the bundle. The ...

1997-10-04

400

Flow regime transfer conditions for two-phase flow in a fracture  

Energy Technology Data Exchange (ETDEWEB)

Between 25 and 30 percent of total known petroleum reserves are contained within oil-laden fractured reservoirs where the dominant flow path is through the fractures. Economic oil recoveries from fractured reservoirs depend on a better understanding of the flow in fractures and networks of fractures. However, the flow of heavy oil and water, and particularly the flow regime map for two-phase immiscible flow has received less attention in contrast with gas-liquid flow in fractures. This paper discussed the use of flow pattern observations in a Hele-Shaw cell to generate two-phase flow regime maps. The paper investigated the effect of fracture gap and fluid viscosities on flow regimes. A correlation based on different flow and fracture properties was developed to define ...

2010-07-01

401

Wear-resistant ceramics in the coal industry  

Energy Technology Data Exchange (ETDEWEB)

The properties of cast basalt and alumina are examined. The ways in which these materials have been used in applications in coal preparation plants, for example in bunker and pipe linings where abrasion and corrosion resistant materials are required, are discussed.

1985-04-01

402

Residential Mercury Spills from Gas Regulators  

UK PubMed Central (United Kingdom)

Many older homes are equipped with mercury-containing gas regulators that reduce the pressure of natural gas in the mains to the low pressure used in home gas piping. Removal of these regulators can...Full Text Available

2006-06-01

403

Radiographic experience with power transmission equipment  

Energy Technology Data Exchange (ETDEWEB)

This paper describes radiography as one of the most efficient and cost effective methods for inspecting electric cabls. Details of one project in particular, i.e., the inspection of high-pressure, oil-filled, pipe-type cables (HPOF) are given. 2 refs.

1980-01-01

405

Laboratory development of +- 600 kVdc pipe type cable systems  

Energy Technology Data Exchange (ETDEWEB)

In 1976, the US Department of Energy and New York State - ERDA granted a contract for the development of a +-600 kV dc underground transmission cable system looking to inevitable future requirements in the US for economic, high-capacity, long-distance underground transmission linking remote generating stations to metropolitan load centers. This project was comprehensive and dealt with three separate system components, i.e., cable, splice, and terminals. In each instance, for each component, development required an intensive R and D effort, focused on the following categories: insulating materials, model testing, design of full-scale prototype, manufacturer of prototype, and laboratory development testing. Insulating papers and oils were selected, and model studies performed, for both self-contained type and pipe type oil-filled cables. However, only the pipe cable design was finally designated for full-size cable manufacture and EHV laboratory ...

1982-07-01

406

Dynamic Rating and Underground Monitoring System (DRUMS)  

Energy Technology Data Exchange (ETDEWEB)

Drums is an acronym for Dynamic Rating and Underground Monitoring System, with specific application to high-pressure pipe-type cable systems which are the predominant means of underground electric power transmission in the United States. The primary objective of this EPRI-sponsored feasibility study was to establish the technical feasibility of seven DRUMS functions and two novel DRUMS communication schemes. The seven DRUMS functions which monitor the system's vital and measurable parameters in real time and perform system diagnostics in the event of component deterioration, malfunction or failure are: Real Time Current Monitoring and Rating; Leak Detection and Location; Fault Location; Pothead Monitoring; Oil Monitoring; Pipe Protection; and Splice Monitoring. The two DRUMS communication schemes are internal to the pipe cable system. Mechanical Communication will use pressure pulses to transmit data along the ...

1991-07-01

407

Behaviour of nonlinear supports on a PWR coolant system during a postulated LOCA. Pt. 1; Effect of modelling methods  

Energy Technology Data Exchange (ETDEWEB)

A 4-loop Pressurised Water Reactor (PWR) primary coolant system has been analysed for the postulated Loss of Coolant Accident (LOCA) event in order to derive peak dynamic loads for qualifying the design of equipment supports and pipe whip restraints. Pipe whip restraints as well as pipe and equipment supports are nonlinear by nature because of the presence of gaps and the different directional stiffnesses arising from snubber, steelwork and geometric and material interaction at the concrete to steel embedment. The different structural idealisations for the supports and restraints have an influence on the dynamic response of the structure. In the first of the two part paper a range of idealisation models for the Steam Generator and Reactor Coolant Pump vertical columns ranging from elastic stiffnesses to bilinear stiffnesses with or without preload were examined. Due to both structural and loading complexity, the behaviour ...

1993-07-01

408

Abrasion wear protection in coal mining  

Energy Technology Data Exchange (ETDEWEB)

A brief description is given of some commercially-available wear-resistant products suitable for use in mine environments. The materials are cast basalt, cast or sintered alumina, and a heat-treated martensitic iron, and they can be used as linings for pipes, bunkers and chutes.

1985-05-01

409

Structural engineering and noise pollution abatement. Improvements that can be measured  

Energy Technology Data Exchange (ETDEWEB)

Structural engineering implies four factors particularly relevant to sonics: airborne noise abatement, insulation of plumbing, by-pass insulation and noise absorption (noise abatement). These are exemplified with special regard to methodical and/or product-specific noise pollution abatement measures. Besides, reference is made to DIN standards 4109 providing both engineers with practical advice and pipe fitters or plumbers with concrete examples for application. VDI recommendations 3733 convey essential knowledge of how to properly apply sonic principles in the planning, design and installation of pipes. (BR).

1985-06-01

410

Probabilistic fracture assessment of surface cracked pipes using strain-based approach  

British Library Electronic Table of Contents (United Kingdom)

Simplified strain-based fracture mechanics equations, established for external surface cracked pipelines subjected to an external bending load, are presented and used in probabilistic assessment of a pipeline girth weld. The model takes into account several parameters, such as variation in crack depth, crack length, internal pressure and material hardening. The critical strain from ductile tearing in the cracked pipeline is found by using the tangency criterion. The reliability problem is solved using first and second order reliability methods for different pipe dimensions and load levels.

2006-01-01

411

Freezing phenomena in ice-water systems  

Energy Technology Data Exchange (ETDEWEB)

The characteristics of solidification and melting are reviewed. The properties of water and ice and the phase diagram of water are discussed with special emphasis on ice density. A concise account of the freezing process and the Stefan problem is presented. To this end, the four stages of freezing are identified, supercooling, nucleation and the formation of dendritic ice, the growth of concentric rings of solid ice at 0{sup o}C and the final cooling of the solid ice are treated in some detail. The subject of bursting of pipes is given particular emphasis. Attention is drawn to a common misconception on pipe bursting and to misleading relationships for the computation of freezing time for ice blockage. Several current applications of melting and freezing systems are outlined. (author)

2002-09-01

412

Computer code development for pipe whip and impact analysis. Progress report for year 2. Load Combination Program. Volume 2  

Energy Technology Data Exchange (ETDEWEB)

A progress report is presented on development of the WIPS computer code, a special purpose code for analysis of whip and impact in nuclear power piping. The computer code and final report are expected to be complete in December 1981. This progress report is an incomplete version of the final report, representing approximately 40% of the volume of the final report. Some sections in the report are complete, some are partially complete, and others are omitted. The report is intended to inform prospective WIPS users of the procedures, theories, and documentation standards which will be used for the computer code and the final report.

1980-12-01

413

Application of probabilistic safety assessment models to risk-based inspection of piping  

International Nuclear Information System (INIS)

From the beginning, one of the most useful applications of Probabilistic Safety Assessment (PSA) is its use in evaluating the risk importance of changes to plant design, operations, or other plant conditions. Risk importance measures the impact of a change on the risk. Risk is defined as a combination of the likelihood of failure and consequence of the failure. The consequence can be safety system unavailability, core melt frequency, early release, or various other consequence measures. The goal in this PSA application is to evaluate the risk importance of an ISI process, as applied to plant piping systems. Two approaches can be taken in this evaluation: Current PSA Approach or the Blended Approach. Both are discussed here.

1996-07-21

414

A study on convective heat transfer with microcapsulated lauric acid slurry in circular pipe  

Energy Technology Data Exchange (ETDEWEB)

The objective of the present study is to reveal thermal characteristic of microcapsulated lauric acid slurry in circular pipe. Test were performed with microcapsulated lauric acid slurry in a heating test section with a constant heat flux boundary condition. Local Nusselt number and the effective thermal capacity were measured. As the size of microcapsulated lauric acid were increased, local Nusselt number of microcapsulated lauric acid slurry were increased. The effective thermal capacity of microcapsulated lauric acid slurry was 0.5 times than it of water.

2003-07-01

415

Development of ultrasonic measurement technique for the determination of vertical two-phase flow pattern  

Energy Technology Data Exchange (ETDEWEB)

In the present study, a new measurement technique which uses a ultrasonic transmission signals in order to determine the vertical two phase flow pattern even under high pressure condition. The ultrasonic measurement system developed in the present study not only provides the measurement functions required for the determination of vertical two phase flow pattern but also makes the real time determination possible. The developed ultrasonic measurement system accurately determined the various vertical two phase flow patterns such as bubbly, slug, churn, annular flow etc. In addition to the determination of flow patterns, qualitative informations for each flow pattern can be obtained, which include void fraction in bubbly flow, length of slug bubble and liquid tail characteristics in slug flow, and stable or transient ...

2002-03-01

416

Understanding and predicting soot generation in turbulent non-premixed jet flames.  

Energy Technology Data Exchange (ETDEWEB)

This report documents the results of a project funded by DoD's Strategic Environmental Research and Development Program (SERDP) on the science behind development of predictive models for soot emission from gas turbine engines. Measurements of soot formation were performed in laminar flat premixed flames and turbulent non-premixed jet flames at 1 atm pressure and in turbulent liquid spray flames under representative conditions for takeoff in a gas turbine engine. The laminar flames and open jet flames used both ethylene and a prevaporized JP-8 surrogate fuel composed of n-dodecane and m-xylene. The pressurized turbulent jet flame measurements used the JP-8 surrogate fuel and compared its combustion and sooting characteristics to a world-average JP-8 fuel sample. The pressurized jet flame measurements demonstrated that the surrogate was representative of JP-8, with a somewhat higher tendency to soot formation. The premixed flame ...

2010-10-01

417

Experimental study and modeling of CH{sub 4}/O{sub 2}/Ar and C{sub 2}H{sub 6}/O{sub 2}/Ar pre-mixing laminar flames; Etude experimentale et modelisation de flammes laminaires de premelange CH{sub 4}/O{sub 2}/Ar et C{sub 2}H{sub 6}/O{sub 2}/Ar  

Energy Technology Data Exchange (ETDEWEB)

New studies are always needed to better determine the physico-chemical processes involved in the combustion of natural gas. The understanding of the reaction mechanisms that lead to the formation of nitrogen oxides or volatile organic compounds requires to identify the inner mechanisms which take place during combustion and in particular the mechanisms of formation of intermediate products. The aim of this study is to analyze the thermal degradation of methane and ethane in low pressure pre-mixed stabilized laminar flames condition, because both of these compounds represent the major part of natural gas composition. The main chemical reaction ways identified in the studied flames and responsible for combustion have been identified after a comparison between experimental results and the computerized simulation performed using an a-priori postulated chemical mechanism. This study stresses on the transfer reaction schemes between the different C1, C2 and C3 oxidation ...

1996-12-31

418

Turbulent break-off flows  

Energy Technology Data Exchange (ETDEWEB)

Different calculated models are presented for turbulent break-off flows and their classification, reflecting the sequence of historical development. The study was done based on equations of viscous liquid of the Navier-Stokes type with development of special phenomenological models of turbulence which take into consideration real properties of the break-off flows based on simpler models of flow presented in the work. In order to calculate two-dimensional turbulent flows, a method of viscous-nonviscous interaction is used. It employs numerical solutions for nonviscous flow and integrated methods of calculating the dissipative region. This method can be extended for calculating the transonic break-off flows, and also break-off in an incompressible fluid when there is cavitation.

1982-01-01

419

Comparative study of three dimensional numerical simulations of particle dispersion in a turbulent air flow  

International Nuclear Information System (INIS)

This paper describes the study of particles' dispersion in an isotropic turbulent flow. The particle's motion and the turbulent flow characteristics are calculated independently. While the particles' displacement is computed by the author's code, the flow is simulated with a commercial code : PowerFLOW. The particles and the flow are coupled through the relative velocity component of the aerodynamic force. When the simulated flow is turbulent, a turbulence regeneration model is used in order to get the flow instantaneous velocity. Validation of the method is done by comparing the particles' dispersion obtained with experimental results from literature and with the results calculated by FLUENT. Good accordance is found between numerical studies and experimental results. However, comparison between results of PowerFLOW ...

2004-05-09

420

Visualization of liquid metal two-phase flow by a real time neutron radiography system  

Energy Technology Data Exchange (ETDEWEB)

In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).

1995-11-01

421

Visualization of liquid metal two-phase flow by a real time neutron radiography system  

International Nuclear Information System (INIS)

In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).

1995-01-01

422

Gas-liquid two-phase flow patterns in parallel channels for fuel cells  

Energy Technology Data Exchange (ETDEWEB)

Two-phase flow in horizontal parallel channels has been experimentally investigated under fuel cell related operating conditions. Pronounced hysteresis is observed in the pressure drop versus flow characteristic curve when starting from either flooded or dry conditions. When gas is introduced into channels initially filled with water (flooded initial condition), both gas and liquid tend to flow predominantly in one channel at low gas or liquid flow velocities. As the gas flow velocity increases, even distribution of gas and liquid flow in both channels is observed, accompanied with a sudden decrease in the pressure drop. On the other hand, even gas and liquid flow distribution between both channels is found at comparatively lower gas flow velocities when starting with dry-gas flow conditions with ...

2008-09-01

423

The effect of flow-hole structure and water chemistry on scale adhesion at the leading edge of a flow hole in a heat exchanger  

International Nuclear Information System (INIS)

In the heat exchangers of power plants, scale deposition may occur, especially at the leading edge of contraction. The growth of scale can lead to an increase in pressure and cause oscillation of the water level. In our previous study, the dependence of flow on contraction geometry was analyzed numerically and empirically. It was shown that the contraction ratio of hydraulic diameter of the flow path contributed greatly to the difference in pressure drop and turbulent kinetic energy at the leading edge of the flow path. In this study, the effect of contraction geometry and flow rate on scale adhesion was studied in AVT chemistry at 270degC using a high-velocity scale-adhesion test loop. The differential pressure and the amount of scale deposited due to scale adhesion at the leading edge of the flow path increased more in a quatrefoil-type flow path than in ...

1999-05-01

424

Principles of room air flow; Grundlagen der Raumluftstroemung  

Energy Technology Data Exchange (ETDEWEB)

The following subjects are dealt with: physics of indoor air flow, flow in individual rooms, exchange of air and pollution between individual building zones and with the outside world, thermal coupling with the building shell, thermal comfort and air quality, evaluation of the ventilation. figs., tabs., refs.

1994-12-31

425

N89-20139 - NASA Technical Report Server (NTRS)  

Science.gov (United States)

REAL ENGINE FLOW SIMULATION. 4 C D - 8 5 - 1 6 9 6 4. FIGURE 2. - COMPLEX FLOW PHENOMENA IN A TURBINE PASSAGE,. SEE TABLE I FOR DESCRIPTION OF NUMBERED FLOW ...

426

Multidimensional two-phase flow regime distribution in a PWR downcomer during an LBLOCA refill phase  

Energy Technology Data Exchange (ETDEWEB)

The multidimensional countercurrent two-phase flow regimes that occur in a pressurized-water reactor (PWR) vessel downcomer during the refill phase of a large-break loss-of-coolant accident are studied using a transparent 1/10 scale model of a PWR vessel. The various flow regimes and their distribution in the downcomer have been identified and mapped for a range of air-water flooding experiments. The two-phase flow patterns that are identified in the downcomer included various types of film flows, droplet flows, countercurrent churn flows and cocurrent flows depending on the flooding condition. Through observation of the two-phase flow dynamics it was deduced that the physical mechanisms associated with the flooding processes could be separated into a liquid entrainment process and a film flow ...

1994-09-01

427

Multidimensional two-phase flow regime distribution in a PWR downcomer during an LBLOCA refill phase  

International Nuclear Information System (INIS)

The multidimensional countercurrent two-phase flow regimes that occur in a pressurized-water reactor (PWR) vessel downcomer during the refill phase of a large-break loss-of-coolant accident are studied using a transparent 1/10 scale model of a PWR vessel. The various flow regimes and their distribution in the downcomer have been identified and mapped for a range of air-water flooding experiments. The two-phase flow patterns that are identified in the downcomer included various types of film flows, droplet flows, countercurrent churn flows and cocurrent flows depending on the flooding condition. Through observation of the two-phase flow dynamics it was deduced that the physical mechanisms associated with the flooding processes could be separated into a liquid entrainment process and a film flow ...

1993-10-01

428

Flow regime transition criteria for upward two-phase flow in vertical tubes  

Energy Technology Data Exchange (ETDEWEB)

Traditional two-phase flow-regime criteria based on the gas and liquid superficial velocities may not be suitable to the analyses of rapid transient or entrance flows by the two-fluid model. Under these conditions, it is postulated that direct geometrical parameters such as the void fraction are conceptually simpler and therefore more reliable parameters to be used in flow-regime criteria than the traditional parameters. From this point of view, new flow-regime criteria for upward gas-liquid flow in vertical tubes have been developed considering the mechanisms of flow-regime transitions. These new criteria can be compared to existing criteria and experimental data under steady-state and fully developed flow conditions by using relative velocity correlations. The criteria showed reasonable agreements with the existing data for atmospheric ...

1984-05-01

429

Flow regime transition criteria for upward two-phase flow in vertical tubes  

International Nuclear Information System (INIS)

Traditional two-phase flow-regime criteria based on the gas and liquid superficial velocities may not be suitable to the analyses of rapid transient or entrance flows by the two-fluid model. Under these conditions, it is postulated that direct geometrical parameters such as the void fraction are conceptually simpler and therefore more reliable parameters to be used in flow-regime criteria than the traditional parameters. From this point of view, new flow-regime criteria for upward gas-liquid flow in vertical tubes have been developed considering the mechanisms of flow-regime transitions. These new criteria can be compared to existing criteria and experimental data under steady-state and fully developed flow conditions by using relative velocity correlations. The criteria showed reasonable agreements with the existing data for atmospheric ...

1984-01-01

430

Cross sectional early mitral flow velocity profiles from colour Doppler.  

UK PubMed Central (United Kingdom)

Instantaneous cross sectional flow velocity profiles from early mitral flow in 10 healthy men were constructed by time interpolation of the velocity data from each point in sequentially delayed two...Full Text Available

1989-09-01

431

Chaotic system of two-phase flow in a small, horizontal, rectangular channel.  

Science.gov (United States)

Various measurement tools that are used in chaos theory were applied to analyze two-phase pressure signals with the objective of identifying and interpreting flow pattern transitions for two-phase flows in a small, horizontal rectangular channel. These me...

1995-01-01

432

Airfoil Computation at High Angles of Attack, Inviscid and Viscous ...  

Science.gov (United States)

shown of inviscid shocked flow with and without separation and shock-free flow with separation. An Euler solu- tion with ... THE existence of flow separation and recirculation is ..... Solutions for AGARD Test Cases," NASA TM, to be published. ...

433

Pulsating stochastic flows accompanying microwave filament/supersonic shock layer interaction  

British Library Electronic Table of Contents (United Kingdom)

The details of pulsating stochastic flows accompanying the interaction of a microwave filament (regarded as a heated rarefied channel) and an aerodynamic body in supersonic flow are examined numerically using the Euler equations. Symmetrical and asymmetrical filament locations relative to the aerodynamic body are considered. The flowfields are characterized by large scale pulsations and small scale stochastic fluctuations. The mechanisms of the formation of these flow structures are discussed. Two qualitatively different kinds of flowfields are observed depending on the magnitude of the filament radius, with domination of the pulsations of flow parameters or stochastic phenomena. Flow instabilities inherent to the problems under interest are described. The problems are considered in both p...

2011-01-01

434

Plasma flow measurement using directional Langmuir probe under weakly ion-magnetized conditions  

Energy Technology Data Exchange (ETDEWEB)

It is both experimentally and theoretically demonstrated that ion flow velocity at an arbitrary angle with respect to the magnetic field can be measured with a directional Langmuir probe. Based on the symmetry argument, we show that the effect of magnetic field on directional probe current is exactly canceled in determining the ion flow velocity, and obtain the generalized relation between flow velocity and directional probe currents valid for any flowing direction. The absolute value of the flow velocity is determined by an in situ calibration method of the probe. The applicability limit of the present method to a strongly ion-magnetized plasma is experimentally examined. (author)

2000-07-01

435

Phenomenological modeling of two-phase flow for LWRs. I. Experimental study of hydrodynamics of inverted annular flow. II. Simulation study of hot leg U-bend two-phase flow  

International Nuclear Information System (INIS)

In FY 1984 three specific tasks which are all related to not-well-understood two-phase phenomena of importance to LWR accidents have been identified under the program. These three tasks are: (1) inverted annular flow experiments and modeling; (2) hot leg U-bend two-phase flow simulation study; and (3) development and evaluation of two-phase flow scaling criteria. Some of the important results obtained under Tasks (1) and (2) are reported in this paper.

1984-10-23

436

Mixed convection flow in a horizontal rectangular channel subjected to a horizontal thermal gradient  

British Library Electronic Table of Contents (United Kingdom)

This paper deals with a mixed convection water flow in a horizontal rectangular duct, uniformly heated from one lateral vertical wall and thermally insulated elsewhere. The supplied heat flux induces a secondary flow, which structure is constituted of one longitudinal roll in the considered aspect ratio (??=?1.9), embedded into a return flow of possibly large stream wise extension (up to twenty channel heights). Such situation induces helicoidal trajectories for the fluid flow particles, which contributes to a heat transfer enhancement compared to purely forced convection flow.

2011-01-01

437

Mixed convection flow in a horizontal rectangular channel subjected to a horizontal thermal gradient  

Science.gov (United States)

This paper deals with a mixed convection water flow in a horizontal rectangular duct, uniformly heated from one lateral vertical wall and thermally insulated elsewhere. The supplied heat flux induces a secondary flow, which structure is constituted of one longitudinal roll in the considered aspect ratio (? = 1.9), embedded into a return flow of possibly large stream wise extension (up to twenty channel heights). Such situation induces helicoidal trajectories for the fluid flow particles, which contributes to a heat transfer enhancement compared to purely forced convection flow.

2011-04-01

438

Low Frequency Phased Array Techniques for Crack Detection in Cast Austenitic Piping Welds: A Feasibility Study  

Energy Technology Data Exchange (ETDEWEB)

Studies conducted at the Pacific Northwest National Laboratory (PNNL) in Richland, Washington have focused on developing and evaluating the reliability of nondestructive testing (NDT) approaches for coarse-grained stainless steel reactor components. The objective of this work is to provide information to the United States Nuclear Regulatory Commission (NRC) on the utility, effectiveness and limitation of NDT techniques as related to inservice testing of primary system piping components in pressurized water reactors. We examined cast stainless steel pipe specimens containing thermal and mechanical fatigue cracks located close to the weld roots and having inner and outer diameter surface geometrical conditions that simulate several water reactor primary piping configurations. In addition, segments of vintage centrifugally cast piping were examined to characterize the inherent acoustic noise and scattering ...

2007-01-01

439

Two-phase flow regime transition criteria in post-dryout region based on flow visualization experiments  

Energy Technology Data Exchange (ETDEWEB)

A visual study of film boiling is carried out to determine the flow regime transition in the post-CHF region. An idealized inverted annular flow is obtained by introducing a liquid jet of Freon 113 through a nozzle, precisely centered with respect to the internal diameter of the test section, with an annular gas flow. The respective ranges for liquid and gas velocities are 0.05-0.5 and 0.03-8.2 m s/sup -1/. Nitrogen and helium are used in the study. For the present configuration, there are four flow regimes; namely, the smooth inverted annular flow-section, the rough wavy, agitated and dispersed flow regimes.

1988-12-01

440

Two-phase flow regime transition criteria in post-dryout region based on flow visualization experiments  

International Nuclear Information System (INIS)

A visual study of film boiling is carried out to determine the flow regime transition in the post-CHF region. An idealized inverted annular flow is obtained by introducing a liquid jet of Freon 113 through a nozzle, precisely centered with respect to the internal diameter of the test section, with an annular gas flow. The respective ranges for liquid and gas velocities are 0.05-0.5 and 0.03-8.2 m s"-"1. Nitrogen and helium are used in the study. For the present configuration, there are four flow regimes; namely, the smooth inverted annular flow-section, the rough wavy, agitated and dispersed flow regimes. (author).

1988-01-01

441

Two-phase flow regime map predictions under microgravity  

International Nuclear Information System (INIS)

In this paper, the widely used models of Taitel-Dukler and Weisman et al. are extrapolated to microgravity levels to compare predicted flow pattern boundaries for horizontal and vertical flows. Efforts have been made to analyze how the two-phase flow models available in the literature predict flow regime transitions in microgravity. The models of Taitel-Dukler and Weisman et al. have been found to be more suitable for extrapolation to a wide range of system parameters than the other two-phase flow regime maps available in the literature. The original criteria for all cases are used to predict the transition lines, except for the transition to dispersed flow regime in case of the Weisman model for horizontal flow. The constant 0.97 on the righthand side of this correlation should be two times that value, i.e., 1.94, in order to match this ...

1988-01-01

442

TECHNICAL REPORT - NASA Technical Reports Server  

Science.gov (United States)

VORTEX VALVE FLOW CHARACTERISTICS. 49. VENTED VORTEX VALVE. 50. VORTEX DIVERTER VALVE- ... 46 AND VORTEX MIXING VALVE FLOW CHARACTERISTICS ...

443

Quantitative cerebral blood flow with Optical Coherence Tomography  

UK PubMed Central (United Kingdom)

Absolute measurements of cerebral blood flow (CBF) are an important endpoint in studies of cerebral pathophysiology. Currently no accepted method exists for in vivo longitudinal...Full Text Available

2010-02-01

444

Gallbladder function and dynamics of bile flow in asymptomatic gallstone disease  

UK PubMed Central (United Kingdom)

AIM: To investigate the effects of gallbladder stones on motor functions of the gallbladder and the dynamics of bile flow in asymptomatic gallstone disease.METHODS: Quantitative hepatobiliary...Full Text Available

2009-06-14

445

GENERATION OF TURBULENCE IN COUETTE FLOW ...  

Science.gov (United States)

... lated Reynolds number for separation is too small. Now ... lol (1959). 6.) F.Schultz-Grunow On stability of Couette flow, AGARD- ...

1962-03-01

446

Effect of Reynolds Number and Periodic Unsteady Wake Flow ...  

Science.gov (United States)

verse pressure gradient, makes it susceptible to flow separation, ...... AGARD, Lecture Series LS-167. [25] Eifler, J., 1975, Zur Frage der freien ...

447

EDA_g.doc - VAMS Project - NASA  

Science.gov (United States)

Jan 31, 2002 ... Sequential Flow of EDA Functionality for Flow with Separation ...... for Automated Air Traffic Management," AGARD Lecture Series No. ...

448

Demonstration of Separation Delay With Glow ... - GLTRS - NASA  

Science.gov (United States)

flow over the suction surface of a modern low- ..... the flow because of its proximity to the separation point ..... Pressure Turbines, AGARD Lecture Series 167, ...

450

Buffet Active Control - Experimental and Numerical Results  

Science.gov (United States)

... high- lift separated compressible flows over airfoils ... Proceedings AGARD-CP- 515, paper 26, Symposium ... Viscous-inviscid flow matching Analysis of ...

2001-06-01

451

Active Dynamic Flow Control Studies on Rotor Blades  

Science.gov (United States)

... of the cycle shows that the separation area ea. ... with suitable flow solvers based on the Reynolds ... AGARD 75th Fluid Dynamics Panel Meeting and ...

2001-06-01

452

A real-time neutron radiography diagnostic of a vertical co-current two-phase flow channel with a hexagonal finned bundle  

International Nuclear Information System (INIS)

A Real-Time Neutron Radiography (RTNR) system is developed to determine two-phase flow parameters for a vertical co-current two-phase flow channel with a hexagonal finned bundle. Image processing techniques are applied to visualize the two-phase flow, and procedures for measuring flow regime, cross-sectional averaged void fraction, time averaged void fraction, and void distribution for this complex geometry are discussed. The results show that the experimental flow regime map agrees well with an existing flow regime model for a hexagonal fined bundle. The hexagonal finned bundle is observed to significantly affect the void fraction, void migration, and void fluctuation along the axial flow channel.

2003-06-01

453

A Survey of Flow Cytometry Data Analysis Methods  

UK PubMed Central (United Kingdom)

Flow cytometry (FCM) is widely used in health research and in treatment for a variety of tasks, such as in the diagnosis and monitoring of leukemia and lymphoma patients, providing the counts of helper-T...Full Text Available

2009-01-01

454

//s /~7 - NASA CR-  

Science.gov (United States)

Valve Flow Characteristics. 3-68. 3-40. Valve Operating Current Vs. Temperature ...... VALVE FLOW CHARACTERISTICS. Acceptance Test 4/29/74. SINs 002 & 004 ...

455

The photophoretic sweeping of dust in transient protoplanetary disks  

CERN Document Server

Protoplanetary disks start their lives with a dust free inner region where the temperatures are higher than the sublimation temperature of solids. As the star illuminates the innermost particles, which are immersed in gas at the sublimation edge, these particles are subject to a photophoretic force. We examine the motion of dust particles at the inner edge of protoplanetary disks due to photophoretic drag. We find that, in a laminar disk, photophoretic drag increases the size of the inner hole after accretion onto the central body has become subdued. This region within the hole becomes an optically transparent zone containing gas and large dusty particles (>>10 cm), but devoid of, or strongly depleted in, smaller dust aggregates. Photophoresis can clear the inner disk of dust out to 10 AU in less than 1 Myr. At late times, the edge reaches a stable equilibrium between inward drift and photophoretic outward drift, at a distance of some tens of AU. Eventually, ...

2006-01-01

456

Stagnation region heat transfer: The influence of turbulence parameters, Reynolds number and body shape  

Science.gov (United States)

The effect of velocity gradient on stagnation region heat transfer augmentation by free stream turbulence was investigated. Heat transfer was measured in the stagnation region of four models with elliptical leading edges with ratios of major to minor axes of 1:1, 1.5:1, 2.25:1, and 3:1. Four geometrically similar, square bar, square mesh, biplane grids were used to generate free stream turbulence with different intensities and length. Heat transfer measurements were made for the following ranges of parameters: Reynolds number, based on leading edge diameter, 37,000 to 228,000; dimensionless leading edge velocity gradient, 1.20 to 1.80; turbulence intensity, 1.1 to 15.9%; and length scale to leading edge diameter ratio, 0.05 to 0.30. Stagnation point heat transfer augmentation by free stream turbulence can be predicted using a modified version of a previously developed correlation for a circular leading edge. Heat transfer augmentation was independent of body shape at the stagnation ...

1994-02-01

457

Radiation processing of wood-plastic composites  

International Nuclear Information System (INIS)

There are three main types of radiation-processed composite material derived from plastics and fibrous natural polymers. The first are the monomer-impregnated, radiation-treated wood-plastic composites (WPC). They became a commercial success in the early 1970s. More recently, work has focused on improving the WPCs by creating in them interpenetrating network (IPN) systems by the use of appropriate multifunctional oligomers and monomers. The main kinetic features of radiation-initiated chain polymerization remain applicable even in impregnated wood. The second type are the plastics filled or reinforced with dispersed wood fiber or other cellulosics (WFRP). In their case, radiation processing offers a new opportunity to apply radiation-reactive adhesion promoters between wood or cellulosic fibers and the thermoplastic matrices. The third type are the laminar composites made by electron beam coating of wood-based agglomerate sheets and boards. This chapter reviews the ...

458

Predictions of nitrogen oxides production in diffusion turbulent flames; Predictions de la production des oxydes d`azote dans les flammes turbulentes de diffusion  

Energy Technology Data Exchange (ETDEWEB)

The suitability of the turbulent combustion flamelets model in order to predict the index of NO{sub x} production in turbulent flames of hydrogen diffusion is analyzed. In the flamelet approach, the turbulent flame is equivalent to a group of laminar flames submitted to a mechanical stretching which generates a chemical disequilibrium. This effect can be described by the stretching or by the scalar dissipation ratio. A numerical modeling is performed in order to evaluate the advantages of both approaches and to compare the behaviour of the NO{sub x} emission index with the experiments of Chen and Driscoll. This study shows that predictions of NO{sub x} emission indexes have a correct behaviour with respect to the Damkoehler number only when the scalar dissipation ratio is used as a parameter to describe the chemical state outside equilibrium. Predictions of the flamelet models are improving when the Damkoehler number increases. On the other hand, the absolute ...

1996-12-31

459

Observation of the limit cycle in the asymmetric plasma divided by the magnetic filter  

Energy Technology Data Exchange (ETDEWEB)

Asymmetric plasma divided by the magnetic filter (MF) is numerically simulated by the one-dimensional particle-in-cell code VSIM1D. Depending on the asymmetry, the system behaves static or dynamic. In the static state, the potentials of the main plasma and the sub-plasma are given by the sheath potentials, {phi}{sub M} - 3T{sub Me}/e and {phi}{sub S} - 3T{sub Se}/e, respectively, with e being an electron charge and T{sub Me} and T{sub Se} being electron temperatures (T{sub Me} > T{sub Se}). In the dynamics state, while {phi}{sub M} - 3T{sub Me}/e, {phi}{sub S} oscillates periodically between {phi}{sub S,min} - 3T{sub Se}/e and {phi}{sub S,max} - 3T{sub Me}/e. The ions accelerated by the time varying potential gap get into the sub-plasma and excite the laminar shock waves. This periodic phenomenon can be understood as a limit cycle due to transitions between two bifurcated states of {phi}{sub S,min} and {phi}{sub S,max}. (author)

2000-08-01

460

Numerical analysis of reaction-diffusion effects on species mixing rates in turbulent premixed methane-air combustion  

Energy Technology Data Exchange (ETDEWEB)

The scalar mixing time scale, a key quantity in many turbulent combustion models, is investigated for reactive scalars in premixed combustion. Direct numerical simulations (DNS) of three-dimensional, turbulent Bunsen flames with reduced methane-air chemistry have been analyzed in the thin reaction zones regime. Previous conclusions from single step chemistry DNS studies are confirmed regarding the role of dilatation and turbulence-chemistry interactions on the progress variable dissipation rate. Compared to the progress variable, the mixing rates of intermediate species is found to be several times greater. The variation of species mixing rates are explained with reference to the structure of one-dimensional premixed laminar flames. According to this analysis, mixing rates are governed by the strong gradients which are imposed by flamelet structures at high Damkoehler numbers. This suggests a modeling approach to estimate the mixing rate of individual species which ...

2010-03-15

461

Hydrogen peroxide for improving premixed methane-air combustion  

Energy Technology Data Exchange (ETDEWEB)

In this study, the effects of hydrogen peroxide on laminar, premixed, methane-air flames at atmospheric pressure and temperature were investigated using CHEMKIN III and GRI 3.5 mechanism. The range of fuel/air equivalence ratio {phi} was varied from 0.6 to 1.2, and the amount of hydrogen peroxide was altered from 0% to 20% volumetric fraction of the methane-hydrogen peroxide (air excluded) mixture. The burning velocity was found to increase with increasing hydrogen peroxide addition, with a relatively larger increase for the fuel-richer mixtures ({delta}S{sub u} up to 15 cm/s for {phi} {approx}=1.2). The adiabatic flame temperature rose with hydrogen peroxide addition, and the temperature rise per unit hydrogen peroxide addition was more significant ({delta}T up to 100 K) for the leaner mixtures. For the same mixture stoichiometry, adding hydrogen peroxide also increased CO concentration and NO{sub x} emissions somewhat. Accordingly, the benefits of adding hydrogen ...

2005-03-01

462

U.S. Department Of Energy's nuclear engineering education research: highlights of recent and current research-II. 4. Studies of Forced-Convection Heat Transfer Augmentation in Large Containment Enclosures  

International Nuclear Information System (INIS)

This paper provides information on heat transfer enhancement due to jet mixing inside a cylindrical enclosure. The work addresses conservative heat transfer assumptions regarding mixing and condensation that have typically been incorporated into passive containment design analyses. The current research presents an interesting possibility for increasing decay heat removal of passive containment systems under combined natural and forced convection. Eliminating these conservative assumptions could provide the basis for a change of containment design and reduce the construction cost. It is found that the ratio of forced- and free convection Nusselt numbers can be predicted as a function of the Archimedes number and a correlated factor accounting for jet orientation and enclosure geometry. To use the small-scale tests for large containment design, scale-up methods and criteria are important for matching the key governing parameters and fluid properties. In the present experiment, a ...

2001-06-17

463

User's guide on butt heat-fusion joining of polyethylene gas pipes. Topical report, July 1986-September 1989. Volume 1  

Energy Technology Data Exchange (ETDEWEB)

Heat fusion is the most common joining method for polyethylene gas distribution piping. Butt fusion was studied with the intent of relating the quality of the joint to the joining conditions. A semi-empirical approach was used. The thermofluid consequences of joining conditions such as heater temperature, heating time and joining parameter were calculated using a computer model. The model was validated by instrumented tests. The strength of the joints was gauged by destructive mechanical testing. Tensile and tensile impact tests were used. Over 150 joints were fabricated using four different polyethylene resins. Most of the data are given in GRI Report No. 88/0276.2 -- Volume 2: Technical Reference on Butt Heat Fusion Joining of Polyethylene Gas Pipes. A parameter, termed the Joining Parameter, was found to characterize the joining conditions. Of the mechanical tests parameters, the impact energy was found to have the best correlation with the ...

1989-09-01

464

Technical reference on butt heat-fusion joining of polyethylene gas pipes. Topical report, July 1986-September 1989. Volume 2  

Energy Technology Data Exchange (ETDEWEB)

Heat fusion is the most common joining method for polyethylene gas distribution piping. Butt fusion was studied with the intent of relating the quality of the joint to the joining conditions. A semi-empirical approach was used. The thermofluid consequences of joining conditions such as heater temperature, heating time and joining parameter were calculated using a computer model. The model was validated by instrumented tests. The strength of the joints was gauged by destructive mechanical testing. Tensile and tensile impact tests were used. Over 150 joints were fabricated using four different polyethylene resins. Most of the data are given in GRI Report No. 88/0276.2 -- Volume 2: Technical Reference on Butt Heat Fusion Joining of Polyethylene Gas Pipes. A parameter, termed the Joining Parameter, was found to characterize the joining conditions. Of the mechanical tests parameters, the impact energy was found to have the best correlation with the ...

1989-09-01

465

Study for developing method of repairing interior of duct. Kanro naimen hoshu koho no kaihatsu kenkyu  

Energy Technology Data Exchange (ETDEWEB)

A hose lining process, used widely for underground service structures, such as for city gas, and water and sewerage pipes, was adopted to repair interiors of underground wire raceways, and improvements were made for power cable pipe use, including long size construction, inner diameter assurance, and flame retardation. The sealing hose as a lining material consists of a fabric layer woven by warps of polybutylene terephthalate (PBT) and wefts of combined PBT fibers and glassfibers, the fabric being coated with polyurethane resin on one side. The other side of the fabric is coated with heat hardening resin made of epoxy resin as the main ingredient and aromatic amine as the hardening agent to assure close adhesion of the sealing hose onto the pipe interior. Mimic raceways were used to verify the lining material for its abrasion coefficient, mechanical strength, wear resistance, water cut-off performance, chemical resistance, ...

1991-03-25

466

Repair of failed 138kV pipe type cable line  

Energy Technology Data Exchange (ETDEWEB)

On February 9, 1995 ComEd experienced a pipe type cable failure on 138kV line 13717. Line 1737 is a bulk power transmission cable circuit connecting The Fisk and Crawford generating stations located within city limits. The line is approximately 4.5 miles long and was originally installed in 1975. This line is forced cooled, has 2,500 KCMIL copper conductors with 505 mils of paper insulation in an 8 inch pritec coated steel pipe. The splices are constructed with Voltalit castings. The failure occurred approximately 3,500 feet from Crawford Station. It was easy to locate the failure since the cable joint casing was breached resulting in the loss of approximately 2,600--2,700 gallons of dielectric fluid. Upon field examination B Phase was determined to have failed. The failure occurred 12 inches inside the casing in an area where it was impossible to install a long connector or add an additional short length of cable to create a piece out. The ...

1996-11-01

467

Innovative coke oven gas cleaning system for retrofit applications. Quarterly technical progress report No. 4, October 1, 1990 to December 31, 1990  

Energy Technology Data Exchange (ETDEWEB)

Work on this coke oven gas cleaning demonstration project (CCT-II) this quarter has been focused on Phase IIB tasks, and include engineering, procurement, construction, and training. Additionally, plans for changes in the operating schedule of the coke plant that affect the demonstration project are described. Engineering efforts are nearly complete. Remaining to be finalized is an assessment of electrical heat tracing/insulation needs for pipe lines, assessment of fire protection requirements, and instrument modifications. Procurement of all major equipment items is complete, except for possible additions to fire fighting capabilities. Major focus is on expediting pipe and structural steel to the project site. Civil construction is complete except for minor pads and bases as required for pipe supports, etc. Erection of the hydrogen sulfide and ammonia scrubber vessels is complete. Installation of scrubber vessel internals ...

1993-10-22

468

Increasing pipe-cable section lengths. Final report  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the results of an experimental program which developed a needed reliable data base on modern pipe-type cable construction from which designers can knowledgeably consider maximizing cable pulling lengths with resulting cost savings. The program comprised evaluations of available commercial constructions over the range of conductor sizes (both copper and aluminum) and insulation thicknesses in general utilization. The work focussed on determining the cable's performance under the three mechanical stress modes to which the cable is subjected during installation; (a) tension and elongation, (b) torsion and (c) sidewall (bearing) pressure in bends. Additionally, the program included experimentation to determine the effective coefficient of friction of the various combinations of modern skid wire materials and pipe filling oils used as lubricants with the cable in both triangular and cradled configuration. The cables ...

1983-03-01

469

Fracture behavior of heat-affected zone in low alloy steels  

International Nuclear Information System (INIS)

Past elastic-plastic fracture studies for leak-before-break (LBB) assessment of low alloy steel pipings have been focused mostly on the behavior of base metals and their weld metals. In contrast, the heat-affected zone (HAZ) of a welded pipe has not been studied in detail primarily because the size of the HAZ is too small to make specimens for mechanical properties measurements. In this study, microstructural analyses, microhardness tests, tensile tests and J-R tests have been conducted as a function of distance from a fusion line and temperature for HAZ materials of SA106Gr.C low alloy piping steels. For the ferrite-pearlite steels such as SA106Gr.C, the HAZ specimens showed a higher yield strength and fracture toughness compared with those of its base metal. These characteristics, despite of grain coarsening, can be explained by cleaner microstructures of HAZ materials with a finer morphology of carbides compared with ...

2001-11-01

470

Evaluation of structural integrity of crossover leg piping system with dynamic whip restraints  

Energy Technology Data Exchange (ETDEWEB)

Interference between the crossover leg of the Reactor Coolant System(RCS) and the Pipe Whip Restraints(PWR) has brought a degradation issue of the integrity of the Reactor Coolant System in Westinghouse type Nuclear Power Plants(NPPs) of Korea. According to the gap inspection carried out during planned overhaul (year 2000), interference between the crossover leg and the PWR was found in each RCS loop. This plant has had the high vibration problem on the RC pump 'B'. The reason for the high vibration in the RC pump 'B' had been massively surveyed and it was found that the crossover leg of RCS contacted with the PWR in hot condition. Since the contact between the crossover leg and the PWR changes the dynamic characteristics of the piping system for the RCS, this is considered as one reason for the high vibration. And a possibility of overstress on the crossover leg due to the contact with the PWR should be ...

2001-07-01

471

Eliminating incrusted solids in drinking water conduits in Cantillana, Seville, Spain; Eliminacion de los solidos incrustados en las conducciones de agua potable de Cantillana (Sevilla)  

Energy Technology Data Exchange (ETDEWEB)

The presence of iron and manganese in underground water due to rock leaching may cause problems in drinking water. the oxidation of these metals produces precipitates which alter water quality (by making it cloudy and bad testing) and may even block supply pipes. This article presents a way eliminating this problem which was tried out in the conduits of Cantillana, a municipality in the province of Seville, Spain. Cleaning the pipes with a mixture of H{sub 2}O{sub 2} + water changes the characteristics of the deposits from flocculant and absorbent to sandy following which they are washed away by the pressure of the water. Once the pipes have been cleaned, a minimal amount of maintenance will prevent the formation of new deposits. This article thus a relatively simple and economical solution for recovering water quality as an alternative to the complicated replacement of the whole network. (Author) 7 refs.

1998-12-01

472

Deposition and diagenesis of a cratonic Silurian platform reef, Pipe Creek Jr. , Indiana  

Energy Technology Data Exchange (ETDEWEB)

Petrographic and geochemical characteristics of the Pipe Creek Jr. paragenesis record the stratigraphic and burial evolution of the cratonic Silurian platform of Indiana during Late Silurian to Pennsylvanian. A variety of several diagenetic fluids acting over geological time affected the reef. The paragenetic sequence is as follows: (1) precipitation of turbid, fibrous, blotchy cathodoluminescent (CL) cement; (2) dolomitization of mud-rich facies; (3) precipitation of clear, zoned CL equant calcite cements; (4) fracturing and karst formation, partially filled by geopetal silt and sandstone; (5) precipitation of clear, dull CL, ferroan to nonferroan equant calcite cement, ferroan dolomite overgrowth and equant dolomite cement in moldic porosity, caves and fractures; (6) microdissolution and hydrocarbon emplacement; and (7) stylolitization. The New Albany Shale was both the hydrocarbon source and top seal to the fossil Pipe Creek Jr. oil field ...

1988-02-01

473

Concrete as secondary containment for interior wall embedded waste lines  

International Nuclear Information System (INIS)

Throughout the DOE complex there are numerous facilities that handle hazardous and radioactive waste solutions. Due to the hazardous constituents of the mixed waste, secondary containment of tank systems and their ancillary piping, in accordance with Resource Conservation and Recovery Act, is a concern for such existing facilities. The Idaho Division of Environmental Quality was petitioned in 1990 for an Equivalent Device determination regarding secondary containment of waste lines embedded in interior concrete walls. The petition was granted; however, it expires in 1996. To address the secondary containment issue, additional studies were undertaken. One study verified the hypothesis that an interior wall pipe leak would follow the path of least resistance through the naturally occurring void found below a rigidly supported pipe and pass into an adjacent room where detection could occur, before any significant deterioration ...

1993-08-17

474

Brazilian onshore pipelines rehabilitation program  

Energy Technology Data Exchange (ETDEWEB)

Brazil currently has an oil and transport system with approximately 15,000 km of pipeline. However, energy needs are now increasing due to rapid population growth and expanding industrial activities in the country. This paper provided details of a pipeline rehabilitation program conducted across 424 km of pipeline in northeastern Brazil. The pipeline crossed 32 municipal districts. Over 37 replacements and upgrades were completed as part of the rehabilitation program. Surveys were completed to verify depth of pipeline cover, as well as to examined the condition of the external pipe coating, and the operational status of the cathodic protection (CP) system. Shutdown of the pipeline was completed during a 14 hour period, and included depressurization, cutting work, welding, and repressurization. Services included pigging to evaluate pipe-wall thickness; corrosion section replacement; an investigation of class locations during the operating life ...

2004-07-01

475

Application of LBB to high energy pipings of PWR in Korea  

Energy Technology Data Exchange (ETDEWEB)

The application of the LBB technology to the newly constructed PWRs has been approved in Korea for several high energy systems that can meet rigorous acceptance criteria. The LBB evaluation had been initiated for Yong-Gwang 3 and 4 units (YGN 3 and 4) which are in service, and subsequently performed for Ul-Chin 3 and 4 units (UCN 3 and 4) which are in construction. The LBB application in Korea is based on the USNRC requirements. The LBB evaluation for YGN 3 and 4 is to eliminate the dynamic effects associated with the postulated DEGB from design basis loads as well as to eliminate pipe whip restraints and jet impingement barriers. There were several issues on the application of LBB to the primary coolant loop and the pressurizer surge line. Of concern were material properties of carbon steel for the primary coolant loop, estimation of crack opening area at the pipe-to-nozzle interface considering the asymmetry, and the leakage crack size which ...

1996-12-31

476

Two-phase flow regime transition criteria in post-dryout region based on flow visualization experiments  

Energy Technology Data Exchange (ETDEWEB)

A visual study of film boiling using photographic and high speed motion-picture methods was carried out to determine the flow regime transition criteria in the post-CHF region. An idealized inverted annular flow was obtained by introducing a liquid jet of Freon 113 through a nozzle, precisely centered with respect to the internal diameter of the test section, with an annular gas flow. The respective ranges for liquid and gas exit velocities were 0.05 to 0.5 and 0.03 to 7.9 m/s. Nitrogen and helium were used in the study. For the present configuration, there are four basic flow regimes. Beginning from the nozzle exit, there is a smooth, inverted annular flow section with liquid in the core and gas in the annulus; followed by the rough wavy section with an intact liquid core, the agitated and the dispersed flow regimes. For a given liquid jet velocity, the axial ...

1987-06-01

477

Two-phase flow regime transition criteria in post-dryout region based on flow visualization experiments  

International Nuclear Information System (INIS)

A visual study of film boiling using photographic and high speed motion-picture methods was carried out to determine the flow regime transition criteria in the post-CHF region. An idealized inverted annular flow was obtained by introducing a liquid jet of Freon 113 through a nozzle, precisely centered with respect to the internal diameter of the test section, with an annular gas flow. The respective ranges for liquid and gas exit velocities were 0.05 to 0.5 and 0.03 to 7.9 m/s. Nitrogen and helium were used in the study. For the present configuration, there are four basic flow regimes. Beginning from the nozzle exit, there is a smooth, inverted annular flow section with liquid in the core and gas in the annulus; followed by the rough wavy section with an intact liquid core, the agitated and the dispersed flow regimes. For a given liquid jet velocity, the axial ...

1987-01-01

478

Analysis of reverse flow in inverted U-tubes of steam generator under natural circulation condition  

International Nuclear Information System (INIS)

In this paper, we report on the analysis of reverse flow in inverted U-tubes of a steam generator under natural circulation condition. The mechanism of reverse flow in inverted U-tubes of the steam generator with natural circulation is graphically analyzed by using the full-range characteristic curve of parallel U-tubes. The mathematical model and numerical calculation method for analyzing the reverse flow in inverted U-tubes of the steam generator with natural circulation have been developed. The reverse flow in an inverted U-tube steam generator of a simulated pressurized water reactor with natural circulation in analyzed. Through the calculation, the mass flow rates of normal and reverse flows in individual U-tubes are obtained. The predicted sharp drop of the fluid temperature in the inlet plenum of the steam generator due to reverse ...

2008-12-01

479

Session 1: Geothermal Pumping Systems and Two-Phase Flow Studies  

Energy Technology Data Exchange (ETDEWEB)

Improvements in electric submersible pumping systems have resulted in a demonstrated downhole running life of one year for low horsepower units operating in 180 C brine. The implementation of a prototype pressurized lubrication system to prevent brine intrusion and loss of lubricating oil from the motor and protector sections has been successfully tested. Second generation pressurized lubrication systems have been designed and fabricated and will be utilized in downhole production pumping tests during FY84. Pumping system lifetime is currently limited by available power cable designs that are degraded by high-temperature brine. A prototype metal-sheathed power cable has been designed and fabricated and is currently undergoing destructive and nondestructive laboratory testing. This cable design has the potential for eliminating brine intrusion into the power delivery system through the use of a hermatically sealed cable from the surface to the downhole motor. The two-phase ...

1983-12-01

480

The significance of local hard zones on the outside of pipeline girth welds: Further studies  

Energy Technology Data Exchange (ETDEWEB)

The NACE MR-01-75 standard imposes a restriction of 22HRC maximum for regions of a pipeline girth weld that are not in direct contact with H[sub 2]S containing environments. TWI have demonstrated in an earlier project for the Pipeline Research Committee (PRC) that it may be permissible to relax this maximum hardness requirement. Such a relaxation, which already exists in the BS4515: 1984 standard, offers potential benefits when applied to the capping pass and heat affected zone of a pipeline girth weld. This report presents additional data to supplement that obtained in a previous PRC project conducted at TWI. Further pipe materials with differing pipe wall thicknesses have been welded, exposed to an internal H[sub 2]S containing environment and examined for sulphide stress corrosion cracking.

1991-10-01

481

Recursive distribution method for probabilistic fracture mechanics and its application to evaluation of LWR piping  

Energy Technology Data Exchange (ETDEWEB)

The present authors have previously developed a new method for Probabilistic Fracture Mechanics (PFM), which they call Recursive Distribution (RD) method. The method is based on the construction of the Lebesgue-Stieltjes measure through a deterministic mapping defining a crack growth process. In the present paper, its theoretical background is first discussed, and the Lebesgue decomposition of the measure is given. Then a numerical example of a Light Water Reactor (LWR)`s piping problem is solved by the present method, and the results are compared with those of the Monte Carlo (MC) method. In addition to leakage probability, a variation in stress cycles of the marginal distribution of an aspect ratio of a semi-elliptical surface crack is calculated, which will be used in a study on LBB evaluation.

1996-12-01

482

Potential migration of organic pollutants in pipes of polyethylene. Study in pipelines of distribution net of drinkable water; Migracion potential de contaminantes organicos en tubos de polietileno. Estudio en tuberias de red de distribuciond e agua potable  

Energy Technology Data Exchange (ETDEWEB)

Polyethylene pipes and connections are being widely used in treated water distribution services. Migration of low molecular weight compounds from the polyethylene into the water can change its final quality. This paper is about the concentrations and identification of the migration compounds found in treated water after staying in contact with low and high-density polyethylene. Identification and quantification were carried out using CLSA (Closed Loop Stripping Analysis) extraction technique and gas chromatography coupled to mass spectrometry (HRGC/HRMS). (Author) 12 refs.

2002-07-01

483

Pitting susceptibility of a pipeline steel with banded microstructure of martensite, ferrite and pearlite  

International Nuclear Information System (INIS)

Early failure of an induction-hardening carbon steel pipe, which was used to transport tailing slurry, was caused by pitting corrosion. The microstructure on the internal pipe surface layer was found being a mixture of martensite, pearlite and ferrite. In this work, the pitting corrosion behavior of each constitute in the microstructure of steel is investigated with electrochemical noise analyses; the electronic properties of passive films were studied with Mott-Schottky relationship. It is found that the passive films formed on the materials under investigation are highly disordered n-type semiconductors. The high-to-low pitting susceptibility is ferrite > martensite > pearlite. The pitting resistance is related to the semiconductive nature of the passive film formed on each constitute. The pitting susceptibility increases with the donor concentration in the passive films. (author)

2003-08-24

484

Equipment for a central heating system with expansion tank, pressure control, water loss supply, de-aeration, recording and control; Apparaat t.b.v. C.V.-installatie met expansievat, drukregeling, waterverliessuppletie, ontluchting, registratie en controle  

Energy Technology Data Exchange (ETDEWEB)

The very low-pressure expansion tank of the title invention is connected to the water in the central heating installation via a connecting pipe with a pump and valves on one side, and on the other side the tank is connected via a connecting pipe with valve to the tap water mains, so that the supply of water can be regulated automatically. Within the expansion tank contact with the outside air is not possible because of an air/water separating floater. By means of recording and control (also remote) of the contents of the expansion tank, the installation pressure and the quantity of supplied water from the expansion tank and the tap water mains, failures and water damage are prevented. 4 figs.

1995-09-01

485

Device for energy-saving heating of fuel in the fuel supply for an internal combustion engine  

Energy Technology Data Exchange (ETDEWEB)

The invention concerns a device for the energy-saving heating of fuel in the supply pipe to an internal combustion engine to regain energy from the fuel itself, particularly but not exclusively for a Diesel engine. A part of the quantity of heat added to the fuel between the tank and the injection nozzles is given up by excess fuel not to the tank, but to the fuel lifted upstream of the injection pump. The device is characterised by the fact that it has a heat exchanger, which absorbs heat from the fuel at the level of the injection pump or upstream of it, and takes this to the fuel above the injection pump. The heat exchanger is preferably mounted upstream of a filter and close to it. A bridging pipe, which may be integrated in the heat exchanger, permits the heat exchanger to be short-circuited depending on the fuel temperature.

1981-02-10

486

Design and Operation of a Novel Capillary Pumped Two-Loop System for Cooling of Electronic Devices  

British Library Electronic Table of Contents (United Kingdom)

Heat pipes, loop heat pipes (LHP), and capillary pumped loops (CPL) have already proven their potential to remove high heat fluxes from a small electronic device and transport the heat to a heat sink that is large enough to transfer it into the ambient air. We introduce a novel two-loop system similar in design to CPLs but with an additional buoyancy-driven fluid loop. Non-degassed methanol is used as a working fluid. Key benefits compared to LHPs and CPLs are easy filling procedure, easy startup, and the tolerance toward noncondensable gases in the fluid. The amount of fluid in the system can be varied over a broad range without affecting the heat transfer performance. Three different inverted-meniscus-type evaporators have been employed in this study. A maximum evaporator heat transfer r...

2012-01-01

487

Code case to substitute the allowable crack angle in rules on fitness-for-service codes of JSME  

International Nuclear Information System (INIS)

The new Code Case to substitute the allowable crack angle for a circumferential surface crack in 'Rules on Fitness-for-Service (FFS)' published from The Japan Society of Mechanical Engineers (JSME). Until now, the angle of a circumferential surface crack was limited below 60deg. This is the limitation with consideration to the stability of the crack if the deep crack penetrates wall of the pipe. Therefore, a long crack (such like an SCC) was obliged to repair or replace even if it was shallow enough. Weld Overlay (WOL) repair in which strength of the original piping is ignored is also inapplicable for the same reason. In order to solve this irrationality, the new Code Case applying to the crack stability assessment when the crack angle exceeds 60deg was established, and allowable crack depth according to the crack angle were defined in it. (author)

2008-07-01

488

Ceramic linings beat coal plant's abrasion/corrosion problems  

Energy Technology Data Exchange (ETDEWEB)

A combination of erosion and corrosion at the Victoria Junction coal preparation plant in Sydney, Nova Scotia was causing serious problems. Schedule 80 mild steel pipes were starting to fail as well as some quarter-inch steel plates in the lauders and chutes. Some corrosion tests were carried out and the high chloride level in the process water was felt to be the single most important contribution to the corrosion problem. Cast basalt was selected as a solution to the pipe wear problem. Three different types of abrasion/corrosion-resistant tiling - basalt tiles, kalceram tiles and ceramic tiles were well suited to the chloride conditions at this plant.

1985-07-01

491

Physical modeling of flow control device test in intake structure  

International Nuclear Information System (INIS)

The seawater in the intake structure flows into the large pump to with draw excess heat from the turbine steam condenser. In the intake structure of a nuclear power plant, undesirable pump operating characteristics such as vortices, impeller damages and non-uniform pump-approach flow around the pump bells take place frequently due to poorly-arranged intake geometry. In this study, physical modeling test was performed to predict the hydraulic phenomenon, and proposed flow control devices.

2000-05-01

494

Electromagnetic fluid valve  

International Nuclear Information System (INIS)

... bypasses control rod drives cylinders electromagnetic pumps fluid flow fluidic