WorldWideScience
1

Transforming Growth Factor-b Induces Differentiation of the Labyrinthine Trophoblast Stem Cell Line SM10  

British Library Electronic Table of Contents (United Kingdom)

The mammalian placenta consists of different trophoblast cell types that assist in the variety of functions required for the maintenance of pregnancy. In rodents, labyrinthine trophoblasts of the placenta are especially important, because they are capable of differentiating into fused labyrinthine cells, which form the feto-maternal exchange surface. Even though the molecular signals triggering labyrinthine trophoblast differentiation are poorly understood, transforming growth factor-b (TGF-b) has been shown to be present in the placental environment and alter trophoblast development. In this study, we investigated the effects of TGF-b on the differentiation of the labyrinthine trophoblast stem cell lines SM10 and HRP-1. RT-PCR analyses demonstrated that while the molecular expression of l...

2005-01-01

2

Electromagnetic fluid valve  

International Nuclear Information System (INIS)

... bypasses control rod drives cylinders electromagnetic pumps fluid flow fluidic

4

Installations having pressurized fluid circuits  

International Nuclear Information System (INIS)

It is an object of the present invention to provide an improved installation having a pressurized fluid circuit incorporating fluidic brakes for restricting fluid flow through a breach of the installation. (author).

9

Integrated Reconfigurable Intelligent Systems (IRIS) for ...  

Science.gov (United States)

... They comprise of a power model for the representation of the electric system, a fluid model that represents the cooling fluid flow, three layers of ...

2009-10-31

10

Complex fluid analysis with the advanced distillation curve approach.  

Science.gov (United States)

An improved method for measuring distillation curves reveals the physicochemical properties of complex fluids such as fuels. PMID:20041713

2010-02-01

11

Sodium arsanilate-induced vestibular dysfunction in meadow voles (Microtus pennsylvanicus): effects on posture, spontaneous locomotor activity and swimming behavior.  

Science.gov (United States)

Vestibular dysfunction was chemically induced in male meadow voles (Microtus pennsylvanicus) by intratympanic injections (30 mg per side) of sodium arsanilate (atoxyl). The control group received intratympanic injections of isotonic saline. After a one-week recovery period the voles were behaviorally assayed for integrity of their labyrinthine systems. All subjects were tested for the presence of the air-righting reflex and body rotation-induced nystagmus. Three weeks later a multivariate assessment of spontaneous motor activity of the voles was carried out in the automated Digiscan Activity Monitor. In addition, the swimming behavior of the voles was examined. Voles with vestibular dysfunction exhibited pronounced postural abnormalities (head dorsiflexion), were not able to swim with their nose above the water for a 1 min test period, and displayed disorientation and thrashing movements. In the Digiscan activity test the atoxyl-treated voles displayed ...

1992-03-15

12

Method for detecting and diagnosing disease caused by pathological protein aggregation  

Energy Technology Data Exchange (ETDEWEB)

A method is provided for detecting pathological macromolecules in a patient. The method is comprised of the following: obtaining body fluid from the patient; pretreating the body fluid; subjecting the pretreated body fluid to size-exclusion chromatography to create an excluded fluid; and analyzing the excluded fluid to detect macromolecules having a predetermined molecular weight. The method also allows for comparing elution spectra with reference spectra of suspect pathologic proteins.

2000-05-16

13

Drilling fluid/formation interaction at simulated in situ geothermal conditions. Final report  

Energy Technology Data Exchange (ETDEWEB)

Interaction of drilling fluids with a geothermal reservoir formation can result in significant permeability impairment and therefore reduced well productivity. This interaction is studied under simulated in situ geothermal conditions of overburden stress, pore fluid pressure, temperature, and pore fluid chemistry. Permeability impairment of an East Mesa KGRA reservoir material is evaluated as a function of stagnation time, drilling fluid, and temperature. Results indicate that all of these parameters contribute significantly to the magnitude and the reversibility of the impairment.

1980-07-01

14

Cytokine signalling in rat pulp interstitial fluid and transcapillary fluid exchange during lipopolysaccharide-induced acute inflammation  

UK PubMed Central (United Kingdom)

The dental pulp consists of loose connective tissue encased in rigid dentinal walls. Because of its topography the tissue has low interstitial compliance and limited capacity to expand during fluid...Full Text Available

2006-05-15

15

Changes in the surface fine structure of ependyma of the rat third ventricle following operative leakage of cerebrospinal fluid.  

UK PubMed Central (United Kingdom)

The role of the ventricular ependyma in the elaboration of cerebrospinal fluid under resting conditions is well documented. In an attempt to elucidate its response to cerebrospinal fluid leakage, male...Full Text Available

1985-01-01

16

Fluid Transport Phenomena in Ocular Epithelia  

UK PubMed Central (United Kingdom)

This article discusses three largely unrecognized aspects related to fluid movement in ocular tissues; namely, a) the dynamic changes in water permeability observed in corneal and conjunctival...Full Text Available

2008-03-01

17

Dynamics of multicomponent vesicles in a viscous fluid  

UK PubMed Central (United Kingdom)

We develop and investigate numerically a thermodynamically consistent model of two-dimensional multicomponent vesicles in an incompressible viscous fluid. The model is derived using an energy...Full Text Available

2010-01-01

20

Techniques and tools for condition monitoring and life prediction of fluid power controls used in fuel handling systems of PHWRs  

International Nuclear Information System (INIS)

Various diagnostics techniques for condition monitoring and life prediction of fluid power components and system are discussed. Though some of the techniques are very promising but may not be accepted because of increase in the instrumentation, it is planned to implement these techniques on various circuits of Fluid Power Lab for further improving and developing these for direct implementation in various fluid power circuits of power reactors. (author). 6 figs.

23

Power transmitting fluids containing esters of hydrocarbyl succinic acid or anhydride with thio-bis-alkanols  

Energy Technology Data Exchange (ETDEWEB)

Mineral oil based power transmitting fluids, such as automatic transmission fluids, are disclosed which contain 0.05 to 2.0 weight percent of an ester of a thio-bis alkanol and a C/sub 12/-C/sub 50/ hydrocarbon succinic acid or anhydride, the ester being a multifunctional additive providing the properties of friction modification, corrosion inhibition, anti-wear, oxidation inhibition and extreme pressure properties to the fluids.

1987-10-27

29

Flow deflector for nuclear fuel element assemblies  

International Nuclear Information System (INIS)

... coolants departure nucleate boiling fluid flow fluidic control devices fuel

33

On the solid-fluid transition zone in welding analysis  

Energy Technology Data Exchange (ETDEWEB)

Equilibrium and energy equations have been developed in describing the solid-fluid transition zone during the melting and solidification of the binary alloys. Due to the existence of the transition region exhibited both solid and fluid phases at the same material point from continuum point of view, mixture theory was utilized to analyze the region. Unlike the Stefan problem, the latent heat due to the phase change appears as a source term in the heat equation. The molten fluid is treated as a thermoviscous and incompressible fluid, whereas the solid is thermoviscoplastic described by the Bodner-Partom/Walker type of constitutive equations. Thermal mechanical behaviors of the solid and the fluid phases are determined separately because of insignificant mechanical interactions between them. Volume fractions of the phases are obtained according to the equilibrium phase diagram. The ...

1993-01-01

34

Condensing curves for a number of mixed-hydrocarbon working fluids  

Energy Technology Data Exchange (ETDEWEB)

Condensing curves are presented for a number of two-component mixed hydrocarbon working fluids which are potentially usable in binary geothermal cycles. Performance of geothermal thermodynamic cycles incorporating these fluids has been evaluated under separate cover; two figures summarizing the results of those evaluations have been included here for continuity. The purpose of this report is: first, to document the condensing curves which were used in the mixed fluid cycle analyses, and second, to provide background useful in the preliminary evaluation of heat rejection systems for advanced geothermal electric power plants utilizing mixed hydrocarbon working fluids. Some concluding remarks are presented.

1981-07-01

35

Aqueous drilling fluids containing fluid loss additives  

Energy Technology Data Exchange (ETDEWEB)

This patent describes an aqueous clay containing drilling fluid having present in an amount sufficient to reduce fluid loss of the drilling fluid, a copolymer of (1) from about 80% to about 98% by weight of acrylic acid and (2) from about 2% to about 20% by weight of itaconic acid. The copolymer has a weight average molecular weight of between about 50,000 to about 1,000,000, being in its free acid or partially or completely neutralized salt form and being at least water dispersible.

1987-03-03

36

Field-controllable electro- and magneto-rheological fluid dampers in flow mode using Herschel-Bulkley theory  

Science.gov (United States)

The Bingham plastic constitutive model has been widely used to predict the post-yield behavior of electro- and magneto- rheological fluids (ER and MR fluids). However, if these fluids experience shear thinning or shear thickening, the Bingham plastic model may not be an accurate predictor of behavior, since the post-yield plastic viscosity is assumed to be constant. In a recent study, it was theoretically and experimentally demonstrated that the Herschel-Bulkley fluid model can be successfully employed when evaluating non- Newtonian post-yield behavior of ER and MR fluids. In this paper, the Herschel-Bulkley model is employed to include a detailed analysis of ER and MR fluid dynamics through pipes and parallel plates. Simplified explicit expressions for the exact formulation are also developed. It is shown that the proposed simplified model of the ...

2000-04-01

37

The inertial dynamics of thin film flow of non-Newtonian fluids  

CERN Document Server

Consider the flow of a thin layer of non-Newtonian fluid over a solid surface. I model the case of a viscosity that depends nonlinearly on the shear-rate; power law fluids are an important example, but the analysis here is for general nonlinear dependence. The modelling allows for large changes in film thickness provided the changes occur over a large enough lateral length scale. Modifying the surface boundary condition for tangential stress forms an accessible base for the analysis where flow with constant shear is a neutral critical mode, in addition to a mode representing conservation of fluid. Perturbatively removing the modification then constructs a model for the coupled dynamics of the fluid depth and the lateral momentum. For example, the results model the dynamics of gravity currents of non-Newtonian fluids even when the flow is not very slow.

2007-01-01

38

Relating Complex Fluid Composition and Thermophysical Properties with the Advanced Distillation Curve Approach  

British Library Electronic Table of Contents (United Kingdom)

Complex fluids have long posed a significant challenge in our ability to characterize and model fluid properties. Here, we consider complex fluids to be mixtures with many components that can differ significantly in polarity and polarizability. The penultimate complex fluid is crude oil, although many other fluids such as finished fuels are also highly complex. We have recently introduced a measurement strategy that can simplify these efforts and provides the added potential of linking chemical composition (i.e. analytical) information with physical property information. In addition to chemical characterization, the approach provides the ability to calculate thermodynamic and transport properties for such complex heterogeneous streams. The technique is based on the advanced distillation cu...

2010-01-01

39

On the anatomy of the adsorption heat versus loading as a function of temperature and adsorbate for a graphitic surface  

British Library Electronic Table of Contents (United Kingdom)

In this paper we review and classify the various patterns of isosteric heat versus loading for adsorption of gases on graphitised thermal carbon black at temperatures ranging from below the 3D triple point to temperatures above it, but less than the 3D critical point. We have identified the features of heat curve and highlighted the microscopic origin of these features. The patterns vary with temperature and with the relative strength of the fluid-fluid interaction and solid-fluid interaction. For simple adsorptives (by simple we meant there is no strong association between fluid particles), the heat curve is typified by fluid-fluid attraction and layering phenomena. For adsorptives showing strong association such as water, ammonia and methanol, the heat curve essentially begins below the ...

2008-01-01

40

The Bidimensional Stefan Problem with Convection: The Time-Dependent Case.  

Science.gov (United States)

This paper considers the time dependent Stefan problem with convection in the fluid phase governed by the Stokes equation, and with adherence of the fluid on the lateral boundaries. The existence of a weak solution is obtained via the introduction of a te...

1982-01-01

41

Mid-trimester diagnosis of bladder neck obstruction by ultrasound and paracentesis.  

UK PubMed Central (United Kingdom)

A bladder neck obstruction was suspected after ultrasound investigation at 16 weeks' gestation. Evaluation of protein content in the amniotic fluid, fetal ascites, and fluid from the overdistended bladder...Full Text Available

1983-06-01

42

Magnetic resonance imaging and computational fluid dynamics (CFD) simulations of rabbit nasal airflows for the development of hybrid CFD/PBPK models  

UK PubMed Central (United Kingdom)

The percentages of total airflows over the nasal respiratory and olfactory epithelium of female rabbits were calculated from computational fluid dynamics (CFD) simulations of steady-state inhalation....Full Text Available

2009-05-01

43

Intrauterine tracheal obstruction, a new treatment for congenital diaphragmatic hernia, decreases amniotic fluid sodium and chloride concentrations in the fetal lamb.  

UK PubMed Central (United Kingdom)

OBJECTIVE: To evaluate the effect of fetal tracheal occlusion on sodium and chloride concentrations in amniotic and tracheal fluid. SUMMARY BACKGROUND DATA: Intrauterine tracheal occlusion has been...Full Text Available

1997-12-01

44

Improvements in or relating to fluid operated devices for moving articles  

International Nuclear Information System (INIS)

The patent relates to fluid operated devices for moving articles. The machine may be used in filling a nuclear fuel canister with fuel pellets where there is a tendency for out of squareness of pellets to produce a jam condition readily cleared by a modest force. (U.K.).

1984-09-27

45

Hydrodynamics in an external field  

CERN Document Server

The methods of statistical dynamics are applied to a fluid with 5 conserved fields (the mass, the energy, and the three components of momentum) moving in a given external potential. When the potential is zero, we recover a previously derived system of parabolic differential equations, called "corrections to fluid dynamics".

2002-01-01

46

Hydrodynamic thickening of lubricating fluid layer beneath sliding mesothelial tissues  

UK PubMed Central (United Kingdom)

The delicate mesothelial surfaces of the pleural space and other serosal cavities slide relative to each, lubricated by pleural fluid. In the absence of breathing motion, differences between...Full Text Available

2008-01-01

47

Gingival crevicular fluid levels of clindamycin compared with its minimal inhibitory concentrations for periodontal bacteria.  

UK PubMed Central (United Kingdom)

Clindamycin concentrations in gingival crevicular fluid and in blood were determined over a 7-h period and were related to the minimal inhibitory concentrations of this agent for 340 bacterial strains...Full Text Available

1981-05-01

48

Density separation of materials by using magnetic fluids  

Energy Technology Data Exchange (ETDEWEB)

The magnetic fluid is a colloidal suspension of magnetite in kerosene, prepared by a low-cost process. Separation is accomplished in an open trough filled with magnetic fluid. A magnetic field is established in the fluid, by energizing an electromagnet having poles on each side of the trough. Due to the design of the magnet poles and air gaps, the magnetic field is strongest at the bottom, about 10,000 oersteds, and uniformly decreases in strength to about 2000 oersteds at the top of the fluid. Therefore, the magnetic field gradient increases with depth. The magnetic force attracts the entire separation medium (magnetic fluid) creating a reaction force of equal magnitude and acting in the opposite direction. This reaction created within a magnetic fluid/magnetic field combination is called a magnetic levitation force. It increases with the field strength. In ...

1980-03-01

49

Computer Simulation of Geothermal Reservoirs.  

Science.gov (United States)

General balance laws and constitutive relations are developed for convective hydrothermal geothermal reservoirs. A fully interacting rock-fluid system is considered; typical rock-fluid interactions involve momentum and energy transfer, and the dependence ...

1975-01-01

50

Changes in Gingival Crevicular Fluid Inflammatory Mediator Levels during the Induction and Resolution of Experimental Gingivitis in Humans  

UK PubMed Central (United Kingdom)

AimThe goal of this study is to characterize the changes in 33 biomarkers within the gingival crevicular fluid during the 3-week induction and 4-week resolution of...Full Text Available

2010-04-01

51

Cerebrospinal Fluid Steroidomics: Are Bioactive Bile Acids Present in Brain?*  

UK PubMed Central (United Kingdom)

In this study we have profiled the free sterol content of cerebrospinal fluid by a combination of charge tagging and liquid chromatography-tandem mass spectrometry. Surprisingly, the most abundant cholesterol...Full Text Available

2010-02-12

52

Centrifugal potential energy : an astounding renewable energy concept  

Energy Technology Data Exchange (ETDEWEB)

A new energy concept known as centrifugal potential energy was discussed. This new energy concept is capable of increasing the pressure, temperature and enthalpy of a fluid, without having to apply work or heat transfer to the fluid. It occurs through a change in the centrifugal potential energy of the flowing fluid in a rotating frame of reference or a centrifugal force field, where work is performed internally by the centrifugal weight of the fluid. This energy concept has resulted in new energy equations, such as the Rotational Frame Bernoulli's Equation for liquids and the Rotational Frame Steady-Flow Energy Equation for gases. Applications of these equations have been incorporated into the design of centrifugal field pumps and compressors. Rather than compressing a fluid with a physical load transfer, these devices can compress a fluid via the ...

2010-07-01

53

Appearance of beta-endorphin-like immunoreactivity in human ventricular cerebrospinal fluid upon analgesic electrical stimulation.  

UK PubMed Central (United Kingdom)

beta-Endorphin-like immunoreactivity in human ventricular cerebrospinal fluid was measured with a specific radioimmunoassay. The subjects were undergoing a surgical procedure for relief of chronic intractable...Full Text Available

1978-10-01

54

An evaluation of cerebrospinal fluid oligoclonal banding confirmed by immunofixation on agarose gel.  

UK PubMed Central (United Kingdom)

The cerebrospinal fluid (CSF) from 115 consecutive patients undergoing diagnostic lumbar puncture or myelography was examined to determine the usefulness of immunofixation, following agarose gel electrophoresis,...Full Text Available

1983-06-01

55

A novel enzyme-based acidizing system: Matrix acidizing and drilling fluid damage removal  

Energy Technology Data Exchange (ETDEWEB)

A novel acidizing process is used to increase the permeability of carbonate rock cores in the laboratory and to remove drilling fluid damage from cores and wafers. Field results show the benefits of the technology as applied both to injector and producer wells.

1995-12-31

56

Two-fluid spray atomisation and pneumatic nozzles for fluid bed coating/agglomeration purposes: A review  

DEFF Research Database (Denmark)

In fluid bed processing in the chemical, food or pharmaceutical industries, pneumatic nozzles are typically used to convert binder or coating liquids into droplets. Producing fine droplets from liquids in a gas phase is termed atomisation, and it involves complex phenomena which are not yet fully understood. This paper provides a systematic and up-to-date review of two-fluid nozzle designs and principles together with a presentation of nozzle fundamentals introducing basic nozzle theory and thermodynamics. Correlations for the prediction of mean droplet diameters are reviewed, compared and accompanied by a discussion of their use.

2008-01-01

57

Origins of acid fluids in geothermal reservoirs  

International Nuclear Information System (INIS)

Acid fluids in geothermal reservoirs are rare. Their occurrence in geothermal systems associated with recent volcanism (Tatun Sumikawa, Miravalles) probably indicates that the geotherml reservoir fluid was derived from volcanic fluid incompletely neutralized by reaction with feldspars and micas. Superheated steam containing HCl (Larderello, The Geysers) forms acid where it condenses or mixes with liquid at moderate temperatures (325 deg. C). Cryptoacidity occurs at Los Humeros where HCl acidity is formed and neutralized without reaching the surface. (author). 28 refs, 9 figs, 2 tabs.

1992-03-01

58

Orbital storage and supply of subcritical liquid nitrogen  

Science.gov (United States)

Subcritical cryogenic fluid management has long been recognized as an enabling technology for key

1990-01-01

59

Modeling Cavitation in Cryogenic Fluids: Validation for Liquid Nitrogen, Hydrogen, and Oxygen  

Science.gov (United States)

This viewgraph presentation provides an overview of research designed to provide a numerical

2003-01-01

60

Low temperature solar-to-electric power conversion system  

Science.gov (United States)

An electric power generating apparatus is described, including: a solar collector; a primary thermal loop including primary thermal fluid; a cavity receiver to receive reflected solar energy from the solar reflector, convert the solar energy into thermal energy, and transmit the thermal energy to the primary thermal fluid by heating the primary thermal fluid not to exceed a given temperature, the given temperature being substantially equal to 700 F; a Stirling engine receiving the primary thermal fluid heated by the cavity receiver, including means to generate mechanical power and means to generate electrical power from the means to generate mechanical power.

1993-07-20

61

JPRS Report, Science & Technology, China, High-Power ...  

Science.gov (United States)

... KDP crystal. ... The KDP crystal has a high nonlinear the degree of matching between the fluid and the window coefficient. ...

1991-10-18

62

Intensifying bactericidal effect of biocides in cutting fluids  

Energy Technology Data Exchange (ETDEWEB)

A study is presented of the influence of ethylenediamine-tetraacetic acid (EDTAA) on the antimicrobial properties of a number of bactericidal additives for cutting fluids. During the testing both the microbiological and primary physical-chemical properties of the cutting fluids were determined. The duration of protective action of the additives vazin, vazin FD, formacide-13, kamcide-5 and furacylin was determined with and without EDTAA in Ukrinol-1 cutting fluid. Though EDTAA itself did not show great duration of antibacterial effect, when combined with the other additives it lengthened their time of protection by a factor of 2.2 to 2.7. 10 references.

1983-06-01

63

Heating of magneto-rheological fluid dampers: a theoretical study  

Science.gov (United States)

This paper focuses on a theoretical model that predicts the temperature increase of Magneto-rheological (MR) fluid dampers experiencing a sinusoidal input motion. A theoretical model is developed to estimate the temperature rise based on the non-linear behavior of the MR fluid damper. This model is solved numerically, and the numerical solution is compared with a known linear solution and experimental result in order to validate the accuracy of the model. Also, a non-dimensional form of the governing equations are developed to examine the key parameters. The non-dimensional terms show the effect of external and internal parameters on the trends of heat dissipation as well as heat generation within the MR fluid damper.

1999-05-01

64

Fluidic-controlled automatic rabbit system  

International Nuclear Information System (INIS)

... v. 15(10) p. 445-449. automation control equipment fluid flow fluidic control

65

Fluidic shut-down system for a nuclear reactor  

International Nuclear Information System (INIS)

... fluid poison control fluidic control devices reactors scram scram rods control

67

Flow Control  

Science.gov (United States)

... 65th AGARD Fluid Dynamics Symposium, Madrid, Spain, October ... of research programs on flow control ... separation, and delta wing flows formed the ...

1991-04-30

68

Feynman-Wiener path integral representation for scalar advected diffusion  

Energy Technology Data Exchange (ETDEWEB)

We write a path-integral expression for the Green function of a advected scalar on a fluid flux. (author)

2000-07-01

69

Evaluation of the fluid force in main feed water control valve for APWRs  

International Nuclear Information System (INIS)

... 2432 v. 43(1) SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS

2006-01-01

70

Computer simulation of interface potentials: Towards a first principle description of complex interfaces?  

British Library Electronic Table of Contents (United Kingdom)

We discuss the feasibility of a hierarchical protocol whereby the description and prediction of adsorbed fluids in confined systems at the mesoscopic scale is achieved by use of interface potentials that are obtained from raw molecular simulation data. Starting from a microscopic description of a fluid?s interface on a flat substrate, we attempt to extract the minimum information that is required in order to predict the behavior of that fluid at larger length scales from coarse grained surface Hamiltonians. A critical assessment of this procedure hinges on controversial aspects of wetting behavior and more generally on the meaning of metastability and instability of thermodynamic systems.

2011-01-01

71

Well preflush fluid  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a preflush fluid for preventing lost circulation during the cementing of a well, the fluid consisting essentially of: (a) water; (b) about 10 to about 30 percent by weight of water (% BWOW) cement; (c) about 5 to about 30% BWOW calcium sulfate selected from the group consisting of calcium sulfate hemihydrate, calcium sulfate dihydrate, and mixtures thereof; and (d) an alkali metal-containing quick-hardening accelerator.

1992-01-21

72

Thermally stable drilling fluid additive  

Energy Technology Data Exchange (ETDEWEB)

This invention relates to a water soluble polymer and method for its preparation. The water soluble polymer exhibits superior thermal stability characteristics when used as an additive in aqueous drilling fluids. The polymer consists of a major portion of a catechol based monomer and a dicarboxylic acid. Other monomers and materials are added to enhance the functional characteristics of the drilling fluid additive. The method of this invention includes the mixing of monomers, polymerization of that mixture and optionally the steps of hydrolysis and sulfonation.

1985-06-25

73

The stability of synthetic cutting fluids to microbe damage  

Energy Technology Data Exchange (ETDEWEB)

The resistance to microbe damages of aqueous solutions of cutting fluids (SOZh), which contain dual and more complex mixtures of known compounds, is studied. Lauric acid, myristic and tridecanic acid give microbic resistance to the compositions of synthetic cutting fluids. A complexing of the compositions as a rule does not support precisely expressed effects of synergism or antagonism.

1983-01-01

74

Sloshing of fluid in horizontal steam generator generated by horizontal and vertical seismic motions  

International Nuclear Information System (INIS)

The nuclear power plants with WWER type reactors are characterized by horizontally situated steam generators (SG). During seismic event the horizontal and vertical ground accelerations induce fluid motion in directions of longitudinal and transversal axis. Resulting dynamic forces act on the SG attachment and could cause the failure of screws. In obvious PSA scenarios, these phenomena are classified as a indirect induced LOCA. In this paper the effects of transversal sloshing of fluid are analyzed.

1989-08-14

75

Self-filling and self-purging apparatus for detecting spontaneous radiation from substances in fluids  

Energy Technology Data Exchange (ETDEWEB)

Disclosed herein is a radiation detector providing for the in situ automatic sampling of fluids containing substances emitting radiation, especially Cerenkov radiation. The detector permits sampling within well casings and is self-purging such that no additional provisions must be established for the storage and disposal of contaminated fluids.

1993-01-01

76

Radionuclide demonstration of ventriculoatrial shunt-cutaneous fistula with cerebrospinal fluid leak  

International Nuclear Information System (INIS)

Radionuclide techniques have commonly been used to assess ventriculovenous shunt function, cerebrospinal fluid dynamics, and for the diagnosis of cerebrospinal fluid leaks. All of these techniques were utilized in this unusual case of retrograde migration of a ventriculoatrial catheter into the neck, with cutaneous fistulization and CSF leak. (orig.).

77

Leak location in fluid filled cables using the PFT method  

Energy Technology Data Exchange (ETDEWEB)

A new method of pinpointing dielectric fluid leaks on pipe-type and self-contained cables using perfluorocarbon tracer (PFT) is presented. The method has successfully been used on the Con Edison transmission system to locate leaks of dielectric fluid on both types of cables. Application of the PFT technique does not require feeder deenergization and provides major advantages over the conventional method of freeze and pressure testing. Description of the method and results of field application are presented in the paper.

1999-01-01

78

CT-guided percutaneous aspiration and drainage of postoperative abdominal fluid collections  

International Nuclear Information System (INIS)

The authors report the personal techniques and the results of CT-guided percutaneous drainage of postoperative abdominal fluid collections. CT-guided percutaneous drainage offers many advantages over surgery: it is less invasive, can be repeated and requires no anesthesia, there are not surgery-related risks and lower morbidity and mortality rates. Moreover, subsequent hospitalization is shorter and costs are consequently reduced. The authors conclude that CT-guided percutaneous drainage is the method of choice in the treatment of postoperative abdominal fluid collections.

1999-03-01

79

The onset of convection in a couple stress fluid saturated porous layer using a thermal non-equilibrium model  

International Nuclear Information System (INIS)

The stability of a couple stress fluid saturated horizontal porous layer heated from below and cooled from above when the fluid and solid phases are not in local thermal equilibrium is investigated. The Darcy model is used for the momentum equation and a two-field model is used for energy equation each representing the solid and fluid phases separately. The linear stability theory is employed to obtain the condition for the onset of convection. The effect of thermal non-equilibrium on the onset of convection is discussed. It is shown that the results of the thermal non-equilibrium Darcy model for the Newtonian fluid case can be recovered in the limit as couple stress parameter C?0. We also present asymptotic analysis for both small and large values of the inter phase heat transfer coefficient H. We found an excellent agreement between the exact solutions and asymptotic solutions when H is very small.

2009-02-16

80

Solar energy conversion system  

Energy Technology Data Exchange (ETDEWEB)

A solar energy collection and conversion system is disclosed in which a cassegrain mirror system is rotated about a diurnal axis, which axis is adjusted for seasonal variations in the incidence of the sun's rays on the earth's surface. A black body absorption cavity filled with translucent or transparent fluid material is used for direct absorption of the sun's rays. The incident solar energy is absorbed directly by the fluid medium. The fluid within the cavity may be maintained under extremely high pressures and temperatures in order to utilize this fluid as a heat storage medium. Such heat storage is facilitated by apparatus which permits a change in the volume of the reflective cavity in response to the temperature or pressure of the fluid within the cavity.

1981-09-01

81

Numerical and experimental investigation of shellside characteristics for RODbaffle heat exchanger  

Energy Technology Data Exchange (ETDEWEB)

RODbaffle heat exchanger is a kind of shell-and-tube heat exchanger with eminent performance. Because of the characteristics of tube bundle support structure, fluid flow on shellside is longitudinal and periodical, and fluid flow is of symmetry in landscape orientation. According to the fluid flow characteristics on shellside and ignoring the impact of inlet, outlet and shell wall, a periodic flow unit duct was taken as the simplified model of the shellside to perform numerical simulation by using CFD code, FLUENT. It was found that the both errors in magnitude of the main fluid velocities and heat transfer coefficients between results of simulation and that of experiment or correlations are less than 10%, and the errors of pressure drop between simulation and correlation are no more than 20%. The detailed characteristics and relation of fluid flow and heat transfer on shellside of ...

2008-05-15

82

Development document for proposed effluent limitations guidelines and standards for synthetic-based drilling fluids and other non-aqueous drilling fluids in the oil and gas extraction point source category  

Science.gov (United States)

The purpose of this rulemaking is to amend the effluent limitations guidelines and standards for the control of discharges of certain pollutants associated with the use of synthetic-based drilling fluids (SBFs) and other non-aqueous drilling fluids in portions of the Offshore Subcategory and Cook Inlet portion of the Coastal Subcategory of the Oil and Gas Extraction Point Source Category. These proposed limitations apply to discharges or effluent generated when oil and gas wells are drilled using SBFs or other non-aqueous drilling fluids (collectively referred to simply as SBFs) in coastal and offshore regions in locations where drilling wastes may be discharged.

1999-02-01

83

Control rod drives  

International Nuclear Information System (INIS)

Purpose: To secure the reactor operation safety by the provision of a fluid pressure detecting section for control rod driving fluid and a control rod interlock at the midway of the flow pass for supplying driving fluid to the control rod drives. Constitution: Between a driving line and a direction control valve are provided a pressure detecting portion, an alarm generating device, and a control rod inhibition interlock. The driving fluid from a driving fluid source is discharged by way of a pump and a manual valve into the reactor in which the control rods and reactor fuels are contained. In addition, when the direction control valve is switched and the control rods are inserted and extracted by the control rod drives, the pressure in the driving line is always detected by the pressure detection section, whereby if abnormal pressure is resulted, the alarm generating device is ...

84

Approximate method for the determination of the response frequency of pipe whip. [With fluid flowing in the pipe at different velocities  

Energy Technology Data Exchange (ETDEWEB)

An approximate analysis based on the virtual work technique, which was used to determine the effect of fluid velocity on the response frequency of a simply supported pipe, resulted in the following conclusions: (1) the critical fluid velocity at which the system becomes statically unstable is 129.5 ft/s; (2) the natural frequency of the pipe decreases as the fluid velocity increases; (3) higher flow rates increase the dynamic coupling of the system, making it much more susceptible to external excitation; (4) as the critical frequency approaches zero and the fluid velocity approaches the critical value, the amplitude becomes greater (though in an actual pipe, damping effects will limit the amplitude somewhat); and (5) the virtual work technique is a convenient method for approximating solutions to most non-linear vibration problems, giving results that are satisfactory for engineering-design purposes.

1980-05-01

85

Application of multi-fluid model in dryout prediction  

International Nuclear Information System (INIS)

Dryout predictions using a multi-flood model for the annular two-phase flow regime are compared against dryout data obtained for BWR condition. The multifluid model treats two-phase flow as composed of distinct fluid regions (fluids) and individual conservation equations are applied to each fluid. Dryout is assumed to occur when flow rate of one of the liquid films becomes zero. The factor is extended to cover dryout data for very short boiling lengths. The present study involves wide ranges in geometries, heat flux distributions, and fluid concentrations. The accuracy of dryout power prediction is found to be as good as that of empirical correlations. It is confirmed that within a single analytical framework, the model can handle various classes of dryout analyses whereas the existing equilibrium models cannot.

1983-01-01

86

On the anatomy of the adsorption heat versus loading as a function of temperature and adsorbate for a graphitic surface.  

Science.gov (United States)

In this paper we review and classify the various patterns of isosteric heat versus loading for adsorption of gases on graphitised thermal carbon black at temperatures ranging from below the 3D triple point to temperatures above it, but less than the 3D critical point. We have identified the features of heat curve and highlighted the microscopic origin of these features. The patterns vary with temperature and with the relative strength of the fluid-fluid interaction and solid-fluid interaction. For simple adsorptives (by simple we meant there is no strong association between fluid particles), the heat curve is typified by fluid-fluid attraction and layering phenomena. For adsorptives showing strong association such as water, ammonia and methanol, the heat curve essentially begins below the condensation heat and then approaches it as loading is increased. This is mainly due to the strong hydrogen bonding ...

2008-05-24

87

Void fraction estimation within rod bundles based on three-fluid model and comparison with X-ray CT void data  

Energy Technology Data Exchange (ETDEWEB)

An interfacial shear stress equation in the dispersed-annular two-phase flow regime has been developed, which is based on a three-fluid model consisting of a liquid film on a rod, vapor and entrained liquid associated with a vapor flow. It is an extension of J.G.M. Andersen's procedure that provides a two-fluid interfacial shear stress equation using the drift flux parameters C{sub 0} and V{sub gj}. This interfacial shear stress equation can take into account a phase and velocity distribution through an equivalence between the drift flux parameters and the interfacial shear stress. Using the three-fluid subchannel analysis code TEMPO with the three-fluid interfacial shear stress model the capability of a three-fluid calculation using the drift flux parameters C{sub 0} and V{sub gj} that reproduce a measured void fraction is demonstrated. A comparison was made with advanced ...

1990-06-01

88

Transport of sorbing solutes in randomly heterogeneous formations: Spatial moments, macrodispersion, and parameter uncertainty  

Energy Technology Data Exchange (ETDEWEB)

Expressions for the spatial moments and macrodispersion tensor for sorbing solutes in heterogeneous formations were presented using a probabilistic model of a fluid residence time coupled with the particle position analysis. The fluid residence time was defined as a fraction of the actual time during which the particle stayed in the mobile fluid phase of the aquifer. The fluid residence time is a random variable whose variability comes as a result of the non-equilibrium sorption properties. The sorbing solute was assumed to be governed with first-order linear kinetics. The closed-form expressions were based on the stationarity in the kinetic process and on the first-order approximation in the hydraulic conductivity field and in the fluid residence time. The non-equilibrium effects were presented as a function of the spatial variability in hydraulic conductivity and temporal ...

1993-06-01

89

Integrated numerical modeling of surface-subsurface-coupled, 2-phase fluid/heat flow in limnological system 1. New type of modeling and experimental study; Shizen suirikei no ryutai{center_dot}netsu ido togo moderingu no kokoromi 1. Ryutai{center_dot}netsu ido no atarashii teishikika to jikkenteki kento  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the comprehensive modeling method of fluid and heat flows in the hydrological system. Based upon the concept that the hydrological system is composed of the air-water 2-phase fluids, and the rock phase, various natural processes are modeled including surface/subsurface 2-phase mass transfer, heat exchanges between fluid phases, between fluid and solid phases, and sensible/latent heat exchanges on the ground surface. A field-oriented numerical simulator is developed, in which a set of governing equations is solved for different variables on the surface and in subsurface regions, respectively. Results of an experimental study are presented, in which transient formulation of heat exchange between fluid/solid phases is examined through matching of the observation and calculated performances. (author)

1999-08-31

90

Integrated numerical modeling of surface-subsurface-coupled, 2-phase fluid/heat flow in limnological system 1. New type of modeling and experimental study. Shizen suirikei no ryutai[center dot]netsu ido togo moderingu no kokoromi 1. Ryutai[center dot]netsu ido no atarashii teishikika to jikkenteki kento  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the comprehensive modeling method of fluid and heat flows in the hydrological system. Based upon the concept that the hydrological system is composed of the air-water 2-phase fluids, and the rock phase, various natural processes are modeled including surface/subsurface 2-phase mass transfer, heat exchanges between fluid phases, between fluid and solid phases, and sensible/latent heat exchanges on the ground surface. A field-oriented numerical simulator is developed, in which a set of governing equations is solved for different variables on the surface and in subsurface regions, respectively. Results of an experimental study are presented, in which transient formulation of heat exchange between fluid/solid phases is examined through matching of the observation and calculated performances. (author)

1999-08-31

91

Fluid flow visualization with neutron radiography. [Using collimated beam of neutrons  

Energy Technology Data Exchange (ETDEWEB)

A technique was developed that permits fluid flow to be visualized even where the flow is completely shrouded by metal. The technique employs real-time neutron radiography, which is similar to x-ray radiography except a collimated beam of neutrons is used. Various combinations of neutron-opaque tracer materials were tested with neutron-transparent fluid. Neutron opaque tracers, such as solid particles, fluid droplets, and streaklines were imaged through metal walls as they convected in neutron-transparent ambient fluid. Visualization of bubbles/voids were evaluated for possible future applications. Surface-flow patterns were also imaged by using neutron-opaque tufts. These techniques were evaluated for image contrast, resolution, and the ability to accurately track fluid flow fields. The techniques were also modeled to optimize contrast in various flow configurations. Imaging ...

1991-01-01

92

Fluid flow visualization with neutron radiography  

International Nuclear Information System (INIS)

A technique was developed that permits fluid flow to be visualized even where the flow is completely shrouded by metal. The technique employs real-time neutron radiography, which is similar to x-ray radiography except a collimated beam of neutrons is used. Various combinations of neutron-opaque tracer materials were tested with neutron-transparent fluid. Neutron opaque tracers, such as solid particles, fluid droplets, and streaklines were imaged through metal walls as they convected in neutron-transparent ambient fluid. Visualization of bubbles/voids were evaluated for possible future applications. Surface-flow patterns were also imaged by using neutron-opaque tufts. These techniques were evaluated for image contrast, resolution, and the ability to accurately track fluid flow fields. The techniques were also modeled to optimize contrast in various flow configurations. Imaging ...

1764-01-01

93

Effects of transverse magnetic field, Prandtl number and Reynolds number on non-Darcy mixed convective flow of an incompressible viscous fluid past a porous vertical flat plate in a saturated porous medium  

Energy Technology Data Exchange (ETDEWEB)

The effect of transverse magnetic field parameter (Hartmann number, Ha) Reynolds number (Re) and Prandtl number (Pr) on the mixed convection flow past a semi-infinite vertical porous plate in a non-Darcian porous medium with variable viscosity and porosity, viscous dissipation and fluid-solid thermal conductivity ratio in the presence of plate transpiration (lateral mass flux) is investigated theoretically and numerically using Keller`s implicit finite difference scheme. It is shown that the Harmann number acts as a retarding force and increases the momentum boundary layer thickness, analogous to the flow against a positive pressure gradient, simultaneously decreasing local skin friction (shear stress). The heat transfer rate is however enhanced by the magnetic field (for positive values of the Eckert number) since the fluid is heated and temperature gradients become reduced between the fluid and the plate, with important ...

1997-01-01

94

A computational fluid dynamics investigation of fluid flow in a dense medium plasma reactor  

International Nuclear Information System (INIS)

Computational fluid dynamics are applied to the study of three-dimensional fluid flow in a dense medium plasma reactor (DMPR) under different operating conditions. Reaction mechanisms and rates for the removal of methyl t-butyl ether (MTBE) in a DMPR are developed from experimental data to determine the plasma volume, the rate of interphase mass transfer and the photolysis rate of MTBE via UV emission from the plasma. The simulations utilize the plasma volume determined from the kinetic data to show that the volume of fluid in contact with the plasma in the DMPR only constitutes a maximum of approximately 10% of the fluid intended to be cycled through the plasma tubules. The simulations also predict appreciable pressure gradients on the surface of the pin electrodes, resulting in a small discharge area located away from the region in which the electric field strength is a maximum. This result has been ...

2007-01-21

95

Thermodynamics &  

Wastenet

... Thermodynamics & Fluid - EA BOOKS About us | My EA Books | Contact us | Authors Home page Currently ...Electronics Environmental Management Mechanical Multi-disciplinary Quality Railways Structural Water CATEGORIES Books Mechanical Thermodynamics & Fluid Thermodynamics & Fluid Display: 10 results ... Display product Add to shopping basket Engineering Thermodynamics: A Computer Approach, 3rd Edition AU$99.09 ex-GST Terms and Conditions A ...textbook for applied or engineering thermodynamics, or as a reference for practicing engineers, the book uses extensive in-text, solved examples and ...

96

The effect of the shear rate-dependent thermal conductivity of non-Newtonian fluids on the heat transfer in a pipe flow  

Science.gov (United States)

The present study investigates the effect of the shear rate-dependent thermal conductivity of non-Newtonian fluids on the heat transfer enhancement in a pipe flow. The constant heat flux as thermal boundary condition was adopted in the thermally developed region. The present analytical results show the heat transfer enhancement over those of a shear rate-independent thermal conductivity fluid. The heat transfer coefficient ratio (h/h{sub 0}) linearly increase with the non-dimensional average velocity difference which is the product of the shear rate-dependence of the thermal conductivity and wall-shear rate.

1996-09-01

97

Heat rejection system  

Energy Technology Data Exchange (ETDEWEB)

A cooling system for rejecting waste heat consists of a cooling tower incorporating a plurality of coolant tubes provided with cooling fins and each having a plurality of cooling channels therein, means for directing a heat exchange fluid from the power plant through less than the total number of cooling channels to cool the heat exchange fluid under normal ambient temperature conditions, means for directing water through the remaining cooling channels whenever the ambient temperature rises above the temperature at which dry cooling of the heat exchange fluid is sufficient and means for cooling the water. 5 figs.

1980-01-22

98

Electron paramagnetic resonance of nitroxide-doped magnetic fluids  

Energy Technology Data Exchange (ETDEWEB)

Electron paramagnetic resonance was used to investigate surface-coated magnetite-based magnetic fluids doped with TEMPOL. Two magnetic fluid samples, having magnetite nanoparticles with average diameter of 94 A and coated with different coating layers (lauric acid plus ethoxylated polyalcohol in one case and oleoylsarcosine in the other case), were doped with TEMPOL (6 mM and pH 7.4) and investigated as a function of the nanoparticle concentration. The resonance field and the resonance linewidth both scale linearly with the nanoparticle concentration.

2002-11-01

99

Buoyancy effects in double-diffusive and mixed convection flows  

Science.gov (United States)

When induced by bottom heating in a horizontal fluid layer which is characterized by forced motion or solute stratification, buoyancy-driven flows may assume a variety of forms. The flows, which are examples of mixed or double-diffusive convection, can strongly influence heat tranfer or the entrainment of stratified fluid. General aspects of each form of convection are reviewed, and emphasis is placed on mixed convection in a horizontal rectangular channel and on double-diffusive convection due to thermally driven mixed-layer development in a solutally stratified fluids. Flow conditions are described, and experimental and theoretical results are presented for related heat-transfer and entrainment parameters.

1986-01-01

100

A multilayered acoustic hyperlens with acoustic metamaterials  

British Library Electronic Table of Contents (United Kingdom)

The acoustic hyperlens can be realized by an alternating layered structure of water and fluid with negative mass density. Based on this alternating layered principle, we propose that an acoustic metamaterial consisting of three layers in water background can be designed to replace the fluid with negative mass density. The effective mass density and bulk modulus of the system which is composed of acoustic metamaterial and water are functions of the frequency. The effective mass density of such a system is close to the negative mass density of the fluid at a specific frequency; thus an acoustic metamaterial hyperlens can be achieved.

2011-01-01

101

Unsteady MHD micro polar flow and heat transfer over a vertical porous moving plate with variable suction  

Energy Technology Data Exchange (ETDEWEB)

The unsteady two-dimensional laminar flow of a viscous incompressible electrically conducting micro polar fluid via a porous medium past a semi-infinite vertical porous moving plate in the presence of a transverse magnetic field is studied. A uniform magnetic field acts perpendicularly to the porous surface in which absorbs the micro polar fluid with a suction velocity varying with time. The effects of material parameters on the velocity and temperature fields across the boundary layer are investigated. The method of solution can be applied for small perturbation approximation. Numerical results of velocity and temperature distributions of micro polar fluids are compared with the corresponding flow problems for a Newtonian fluid. (author)

2001-07-01

102

Thoracoscopy in Children: Is a Chest Tube Necessary?  

UK PubMed Central (United Kingdom)

PurposeHistorically, a chest tube or drain has been left following a thoracic operation to allow drainage of air or fluid in the postoperative period. However, in...Full Text Available

2009-04-01

103

Thermal Performance of Low Layer Density Multilayer Insu1ation Using Liquid Nitrogen  

Science.gov (United States)

In order to support long duration cryogenic propellant storage, the Cryogenic Fluid Management (CFM)

2011-01-01

104

The use of tracers to analyze the effects of reinjection into fractured geothermal reservoirs  

Science.gov (United States)

This paper discusses the use of tracers as a reservoir engineering tool in fractured geothermal reservoirs. The principle concern in injecting cooler spent fluids into a fractured reservoir is that the fluids may move through high permeability channels and return to the production wells after contacting a relatively small volume of rock. As a consequence of this rapid transport, the fluids will be only partially reheated and after a short period time will effectively mine the heat from the limited volume of rock. The production wells will then experience a rapid and premature reduction in thermal output. Tracers can be used to infer the existence of high mobility conduits between injection and production wells and to monitor chemical changes of an injected fluid. Since tracer arrival precedes thermal breakthrough, tracer tests are a very useful forecasting tool.

1987-01-01

105

The N-terminal domain of a-dystroglycan, released as a 38kDa protein, is increased in cerebrospinal fluid in patients with Lyme neuroborreliosis  

British Library Electronic Table of Contents (United Kingdom)

a-Dystroglycan is an extracellular adhesion protein that is known to interact with different ligands. The interaction is thought to stabilize the integrity of the plasma membrane. The N-terminal part of a-dystroglycan may be proteolytically processed to generate a small 38kDa protein (a-DG-N). The physiological significance of a-DG-N is unclear but has been suggested to be involved in nerve regeneration and myelination and to function as a potential biomarker for neurodegenerative and neuromuscular diseases. In this report we show that a-DG-N is released into different body fluids, such as lachrimal fluid, cerebrospinal fluid (CSF), urine and plasma. To investigate the significance of a-DG-N in CSF we examined the levels of a-DG-N and known neurodegenerative markers in CSF from patients di...

2011-01-01

106

Sunflower i condenser-subcooler topical re- port, jun. 1960 - aug. 1962  

Science.gov (United States)

Fluid dynamic design criteria for mercury condenser-subcooler component for sunflower power conversion system

1964-01-01

107

Study of ebullated bed fluid dynamics for H-Coal. Quarterly progress report No. 2, December 1, 1977--February 28, 1978  

Science.gov (United States)

The H-Coal ebullated bed reactor contains at least four discrete components: gas, liquid, catalyst, and unconverted coal and ash. Because of the complexity created by these four components, it is desirable to understand the fluid dynamics of the system. The objective of this program is to establish the dependence of the ebullated bed fluid dynamics on process parameters. This will permit improved control of the ebullated bed reactor. Progress has been made in the study undertaken for defining the hydrodynamic properties of gas/liquid/solid systems as related to the H-Coal process. The literature search was completed, and a report will be issued shortly. Design and construction of the fluid dynamics unit proceeded as planned. Unit completion is scheduled for May 1, 1978.

1978-03-01

108

Study of Contemporary Electronic Components under a Fluid ...  

Science.gov (United States)

... The effects of these voids were more noticeable for tantalum and aluminum electrolytic capacitors, which usually exhibited severe case deformation ...

1973-03-01

109

Soret and Dufour effect on double diffusion mixed convection from a vertical surface in a porous medium saturated with a non-Newtonian fluid  

British Library Electronic Table of Contents (United Kingdom)

A non-similar boundary layer analysis is presented to study the flow, heat and mass transfer characteristics of non-Darcian mixed convection of a non-Newtonian fluid from a vertical isothermal plate embedded in a homogeneous porous medium with the effect of Soret and Dufour and in the presence of either surface injection or suction. The value of the mixed-convection parameter lies between 0 and 1. In addition, the power-law model is used for non-Newtonian fluids with exponent n1 for dilatant fluids. Furthermore, the coordinates and dependent variables are transformed to yield computationally efficient numerical solutions that are valid over the entire range of mixed convection, from the pure forced-convection limit to the pure free-conve...

2010-01-01

110

STUDY OF METHODS FOR IMPROVING SYNTHETIC ...  

Science.gov (United States)

... At no time must any solution or water temper- atures exceed 72°F, with all fluids maintained as close as possible to 700F. ...

1963-05-15

111

Properties of molecular solids and fluids at high pressure and temperatures  

Energy Technology Data Exchange (ETDEWEB)

This renewal request for DOE grant DE-FG02-86ER45238, is dedicated to providing a complete thermodynamic profile of solids fluids, and fluid mixtures, over a wide range of temperatures and pressures. We are partially motivated by technological interest in detonation, combustion, superhard high pressure materials, and high temperature superconductors, which are important components of interest of various DOE laboratories. Our work on fluids and solids, composed of simple molecules, involves the determination of structures, phase transitions, pressure-volume relations, phonon, vibron, and libron modes of excitation, sound velocities, specific heats, thermal expansion, virial coefficients, sublimation energies, and orientational translational, and magnetic correlations. We hope that the study of these systems under extreme thermodynamic conditions will lead to exotic new materials of value, as well as enhanced fundamental ...

1992-03-01

112

Pharmacological optimization of tissue perfusion  

UK PubMed Central (United Kingdom)

After fluid resuscitation, vasoactive drug treatment represents the major cornerstone for correcting any major impairment of the circulation. However, debate still rages as to the choice of agent, dose,...Full Text Available

2009-07-01

113

Perfect and Incompressible Fluid Flow in Turbomachines.  

Science.gov (United States)

A method for calculating flow through an airfoil cascade drawn on a surface of revolution is discussed. The three-dimensional flow was assumed to be represented by part-channels of varying width. The basic equations are the equation of continuity and the ...

1974-01-01

114

PROCEEDINGS OF THE 1966 HEAT TRANSFER AND FLUID ...  

Science.gov (United States)

... mass of gray gas by thermal radiation; An experimental study of the turbulent wake behind a cone at M = 5; Heat transfer augmentation by steady ...

115

Novel Magnetic Fluids for Breast Cancer Therapy  

Science.gov (United States)

... metal-oleate complexes. At this point, this method has been reported only for iron nanoparticles [15]. We have demonstrated ...

2008-01-01

116

Locally invasive lymphangiosarcoma in a young domestic shorthair  

British Library Electronic Table of Contents (United Kingdom)

A 2-year-old, female spayed, domestic shorthair cat presented to the University of Missouri-Veterinary Medical Teaching Hospital (UMC-VMTH) with an approximately 11-month history of fluid-draining pockets along her ventral thorax and axillae. The skin in these regions was erythematous, and multiple areas drained a serous to serosanguinous fluid. Fluid-filled, nodules formed along the ventrum, but these nodules disappeared as fluid drained spontaneously. Histologic assessment of skin biopsies revealed areas of vascular proliferation extending along the deep margin of the section and rare instances of invasion into the superficial dermis. These vascular channels were devoid of cells, lined by variably pleomorphic endothelial cells which had a low mitotic index. Based on the mild to moderate ...

2011-01-01

117

Identification and application of black-box model for a self-sensing damping system using a magneto-rheological fluid damper  

British Library Electronic Table of Contents (United Kingdom)

In vibration control field, magneto-rheological (MR) fluid dampers are semi-active control devices that have recently begun to receive more attention. This paper presents a black-box model (BBM) for identification of a MR fluid damper and its application to vibrating control systems using that damper with self-sensing behavior. A model named ''black-box'' is a simple direct modeling method which is designed for a typical MR fluid damper using the self-tuning fuzzy technique. The characteristics of the researched damper are directly estimated through a fuzzy mapping system. In order to improve the accuracy of the proposed model, the back propagation algorithm and gradient descent method were used to train the fuzzy parameters to minimize the model error function. Consequently, the BBM with ...

2010-01-01

118

Geometry of elastic hydrofracturing by injection of an over pressured non-Newtonian Fluid  

CERN Document Server

The nucleation and propagation of hydrofractures by injection of over pressured fluids in an elastic and isotropic medium are studied experimentally. Non-Newtonian fluids are injected inside a gelatine whose mechanical properties are assumed isotropic at the experimental strain rates. Linear elastic theory predicts that plastic deformation associated to breakage of gelatin bonds is limited to a small zone ahead of the tip of the propagating fracture and that propagation will be maintained while the fluid pressure exceeds the normal stress to the fracture walls (Ch\\'avez-\\'Alvarez,2008) (i.e., the minimum compressive stress), resulting in a single mode I fracture geometry. However, we observed the propagation of fractures type II and III as well as nucleation of secondary fractures, with oblique to perpendicular trajectories with respect to the initial fracture. In the Video (http://hdl.handle.net/1813/14122) experimental ...

2009-01-01

120

Evaluation of CFD to Determine Two-Dimensional Airfoil ...  

Science.gov (United States)

rotor flow field in which the main rotor operates. The majority of ..... early separation predicted by their CFD code was ...... Airfoil, AGARD Fluid Dynamics Panel ...

121

Design and Operation of a Novel Capillary Pumped Two-Loop System for Cooling of Electronic Devices  

British Library Electronic Table of Contents (United Kingdom)

Heat pipes, loop heat pipes (LHP), and capillary pumped loops (CPL) have already proven their potential to remove high heat fluxes from a small electronic device and transport the heat to a heat sink that is large enough to transfer it into the ambient air. We introduce a novel two-loop system similar in design to CPLs but with an additional buoyancy-driven fluid loop. Non-degassed methanol is used as a working fluid. Key benefits compared to LHPs and CPLs are easy filling procedure, easy startup, and the tolerance toward noncondensable gases in the fluid. The amount of fluid in the system can be varied over a broad range without affecting the heat transfer performance. Three different inverted-meniscus-type evaporators have been employed in this study. A maximum evaporator heat transfer r...

2012-01-01

122

Bibliography of Documents Related to the Theory, Operation ...  

Science.gov (United States)

... 28, No. 12B, December 1986, pp. 1931-1942. Dattner, A. and Eninger, J., "Studies of a Coaxial Plasma Gun," The Physics of Fluids, Vol. 7, No. ...

1990-11-01

123

Analysis of the omnium-g receiver  

Energy Technology Data Exchange (ETDEWEB)

A thermal analysis of the Omnium-G receiver is presented and the technique is shown to be generally applicable to solar thermal receivers utilizing a directly heated thermal mass. The thermal loss coefficient, including reradiation losses, is calculated and shown to agree quite well with the experimentally measured thermal loss coefficient. The rate of heat transfer to the working fluid is also analyzed and the analysis is used to show that the Omnium-G receiver is well matched to the water/steam working fluid because the steam outlet temperature is almost the same as the receiver temperature. A general procedure for calculating receiver performance is presented. With this procedure, the energy delivery to any working fluid, the delivered temperature of the working fluid, and the pressure drop through the receiver can be determined. An example of the calculation is also presented.

1980-03-01

124

Advanced distillation curve measurements for corrosive fluids: Application to two crude oils  

British Library Electronic Table of Contents (United Kingdom)

We have recently introduced several important improvements in the measurement of distillation curves for complex fluids. The modifications include a composition-explicit data channel for each distillate fraction (for both qualitative and quantitative analysis) and corrosivity assessment of each distillate fraction. The composition-explicit information is achieved with a new sampling approach that allows precise qualitative as well as quantitative analyses of each fraction, on the fly. We have applied the new method to a variety of fluids, including simple n-alkanes, rocket propellant, gasoline, jet fuels, and a hydrocarbon fluid made corrosive with dissolved hydrogen sulfide. In the current contribution, we present the application of the advanced distillation curve method to two samples of...

2008-01-01

125

Adsorption Kinetics of Surfactants at Fluid-Fluid Interfaces  

CERN Document Server

We review a new theoretical approach to the kinetics of surfactant adsorption at fluid-fluid interfaces. It yields a more complete description of the kinetics both in the aqueous solution and at the interface, deriving all equations from a free-energy functional. It also provides a general method to calculate dynamic surface tensions. For non-ionic surfactants the results coincide with previous models. Common non-ionic surfactants are shown to undergo diffusion-limited adsorption, in agreement with experiments. Strong electrostatic interactions in salt-free ionic surfactant solutions are found to lead to kinetically limited adsorption. In this case the theory accounts for unusual experimental results which could not be understood using previous approaches. Added salt screens the electrostatic interactions and makes the ionic surfactant adsorption similar to the non-ionic case. The departure from the non-ionic behavior as the salt concentration is decreased is ...

1997-01-01

126

Active Dynamic Flow Control Studies on Rotor Blades  

Science.gov (United States)

... of the cycle shows that the separation area ea. ... with suitable flow solvers based on the Reynolds ... AGARD 75th Fluid Dynamics Panel Meeting and ...

2001-06-01

127

Wind instability of a foam layer sandwiched between the atmosphere and the ocean  

CERN Document Server

Kelvin-Helmholtz instability of short gravity waves is examined in order to explain the recent findings of the decrease in momentum transfer from hurricane winds to sea waves. A three-fluid configuration of a foam layer between the atmosphere and the ocean is suggested to provide signifficant stabilization of the system and shifting the marginal critical wavelength to the shortwave part of the spectrum. It is conjectured that such stabilization leads to the observed drag reduction. The high contrasts in three fluid densities provide a universal mechanism for stabilizing surface perturbations.

2007-01-01

128

Themis solar receiver  

Energy Technology Data Exchange (ETDEWEB)

The conception of a solar receiver intended to equip a tower power-station has to combine multiple requirements: very highly concentrated solar flux, unsteady in time and space; necessity to obtain a high efficiency; respect of the physical limits of the materials and of the fluid. The description of Themis solar receiver and of its operation is preceded by considerations which have led to the choice of the cavity, of the fluid and of its circulation.

1982-01-01

129

Power fluidics and the environment  

International Nuclear Information System (INIS)

This paper reviews power fluidics technology in the nuclear industry giving emphasis also on its potential uses in chemical plants and in flood and irrigation control. This is a technology of controlling process fluids by purely hydrodynamic methods, which should increase system reliability by eliminating valves, pumps and other fluid control devices that are often causes of failure. This review indicates that the hydrodynamics of fluidic components are not satisfactorily understood at present and may be more complex than similar theory in electronics.

130

Physical therapy applications of MR fluids and intelligent control  

Science.gov (United States)

Resistance exercise has been widely reported to have positive rehabilitation effects for patients with neuromuscular and orthopaedic conditions. This paper presents an optimal design of magneto-rheological fluid dampers for variable resistance exercise devices. Adaptive controls for regulating the resistive force or torque of the device as well as the joint motion are presented. The device provides both isometric and isokinetic strength training for various human joints.

2005-05-01

131

Oil well drilling clay conditioners and method of their preparation  

Energy Technology Data Exchange (ETDEWEB)

Drilling fluid additives are prepared by oxidation of sulfonated lignin-containing materials with manganese dioxide under highly acidic conditions to make manganese lignosulfonates. Additional improvements in the rheological properties of the additives may be obtained by complexing the manganese lignosulfonate so obtained with a heavy metal cation (preferably iron or copper), by, for example, addition of ferrous sulfate or ferric sulfate to the manganese lignosulfonate. These products show the requisite combination of rheological properties for a satisfactory drilling fluid additive or conditioner.

1984-05-08

132

Heterogeneous mechanism of nucleation in a superheated cryogenic fluid flow  

Energy Technology Data Exchange (ETDEWEB)

A model of heterogeneous mechanism of nucleation on impurity particles in a fluid volume is proposed. The particle spectrum is reproduced by solving the ''inverse'' problems on stationary outflow of a boiling parahydrogen with the use of experimental data of authors. A relation for a closure of the equation system describing a non-equilibrium outflow is obtained. It is shown that within the investigated parameter range one manages to calculate the characteristics of a stationary outflow with a satisfactory accuracy.

1984-03-01

133

Heat transfer from magneto-rheological fluid dampers  

Science.gov (United States)

This paper presents a theoretical study of heat transfer from magneto-rheological fluid (MRF) dampers. A lumped system model is developed which is capable of predicting the temperature rise for any size MRF damper. As a case study example, finned and unfinned dampers are compared for automotive-size MRF dampers. The results demonstrate that heat transfer from these devices can be enhanced considerably with the use of fins.

2000-04-01

134

Dimension reduction in fluid dynamics equations  

British Library Electronic Table of Contents (United Kingdom)

A method for transforming the Euler and Navier-Stokes equations and a complete system of fluid dynamics equations in three dimensions to a closed system on any moving surface is proposed. As a result, for an arbitrary geometric configuration, the dimension of the equations is reduced by one, which makes them convenient for numerical simulation. The general principles of the method are described, and verifying examples are presented.

2011-01-01

135

Depth of origin of the gas content in thermal waters  

Energy Technology Data Exchange (ETDEWEB)

The gas composition of recent thermal waters is in perfect conformity with their geologic-tectonic positions. The composition of gas-liquid inclusions in the basic-hyperbasic xenoliths of basaltoid lavas depends on the depth from which xenoliths are supplied. (The depth is determined by using the methods of geological thermobarometers). By comparing available data the conclusion was drawn that the gas compositions of thermal waters reflect the depth of generation of deep fluid which heats them and depends on the penetration depth of the fluid-conducting fissure zones.

1980-01-01

136

Density Currents  

Science.gov (United States)

In this activity, students will make a turbidity current. They will discover how fluids of differing densities interact with one another, learn some ways the densities of fluids can be changed and observe how density currents transport and deposit tremendous amounts of sediment in lakes and in the ocean. Additional options allow students to create and observe different kinds of density currents.

137

Thermomechanical vibration analysis of a functionally graded shell with flowing fluid  

Energy Technology Data Exchange (ETDEWEB)

This paper reports the results of an investigation into the vibration of functionally graded cylindrical shells with flowing fluid, embedded in an elastic medium, under mechanical and thermal loads. By considering rotary inertia, the first-order shear deformation theory (FSDT) and the fluid velocity potential, the dynamic equation of functionally graded cylindrical shells with flowing fluid is derived. Here, heat conduction equation along the thickness of the shell is applied to determine the temperature distribution and material properties are assumed to be graded distribution along the thickness direction according to a power-law in terms of the volume fractions of the constituents. The equations of eigenvalue problem are obtained by using a modal expansion method. In numerical examples, effects of material composition, thermal loading, static axial loading, flow velocity, medium stiffness and shell geometry parameters on ...

2008-11-15

138

The onset of convection in a couple stress fluid saturated porous layer using a thermal non-equilibrium model  

Energy Technology Data Exchange (ETDEWEB)

The stability of a couple stress fluid saturated horizontal porous layer heated from below and cooled from above when the fluid and solid phases are not in local thermal equilibrium is investigated. The Darcy model is used for the momentum equation and a two-field model is used for energy equation each representing the solid and fluid phases separately. The linear stability theory is employed to obtain the condition for the onset of convection. The effect of thermal non-equilibrium on the onset of convection is discussed. It is shown that the results of the thermal non-equilibrium Darcy model for the Newtonian fluid case can be recovered in the limit as couple stress parameter C{yields}0. We also present asymptotic analysis for both small and large values of the inter phase heat transfer coefficient H. We found an excellent agreement between the exact solutions and asymptotic solutions when H is very ...

2009-02-16

139

The condition monitoring of fluid-filled taped cables employed in underground transmission through dissolved gas analysis  

Energy Technology Data Exchange (ETDEWEB)

There is an urgent need to monitor the condition of fluid-filled taped (FFT) cables. The Dissolved-Gas Analysis (DGA) technique that has been successfully applied to power transformers holds great potential for the preventive maintenance of FFT cables. However, before this emerging technique can be properly applied to cables, a suitable fluid sampling and subsequent gas analysis method had to be developed, including the generation of both laboratory and field data to aid in data interpretation. Data on gas saturation levels in various cable fluids have been presented. This paper describes a novel method developed specifically for FFT cables and discusses field results so obtained. The type, distribution and concentration of gases from fluid alone and paper alone under electrical stress has been presented, including the differences between normal and not-so-normal cable systems as demonstrated by DGA. ...

1994-12-31

140

Novel reduced pressure-balance syringe for chromatographic analysis.  

Science.gov (United States)

When withdrawing a fluid sample (for additional chromatographic analyses) from an apparatus operated at a reduced pressure, a typical syringe proves to be ineffective (even if it is equipped with a gas tight plunger). It simply does not create enough pressure differential to remove a fluid sample from a reduced pressure environment. We encountered such a situation as part of efforts to extend the operation of the advanced distillation curve protocol to reduced pressures. The problem was solved by the development of a pressure balance syringe that allows reliable and precise sampling from an apparatus operating at sub-ambient pressures. This new device uses an external vacuum source to evacuate a syringe barrel, allowing a user to withdraw fluid samples from environments with pressures as low as 0.5kPa. To demonstrate the operation of the newly developed device, distillate analyses were performed on two ...

2010-09-19

141

Nevada Nuclear Waste Storage Investigations: Exploratory Shaft Facility fluids and materials evaluation  

Energy Technology Data Exchange (ETDEWEB)

The objective of this study was to determine if any fluids or materials used in the Exploratory Shaft Facility (ESF) of Yucca Mountain will make the mountain unsuitable for future construction of a nuclear waste repository. Yucca Mountain, an area on and adjacent to the Nevada Test Site in southern Nevada, USA, is a candidate site for permanent disposal of high-level radioactive waste from commercial nuclear power and defense nuclear activities. To properly characterize Yucca Mountain, it will be necessary to construct an underground test facility, in which in situ site characterization tests can be conducted. The candidate repository horizon at Yucca Mountain, however, could potentially be compromised by fluids and materials used in the site characterization tests. To minimize this possibility, Los Alamos National Laboratory was directed to evaluate the kinds of fluids and materials that will be used and their potential ...

1988-11-01

142

Modeling and field studies of radon-222 in geothermal reservoirs  

Science.gov (United States)

Radon-222 was shown to be useful in-situ tracer for studying thermodynamic, geologic, and transport properties of geothermal reservoirs. The relationships to reservoir properties are based on steady-state and non-steady-state models which incorporate the thermodynamic state and relative mobility of the fluids, and partitioning between the fluid phases. The steady-state thermodynamic models assume equilibrium between radon emanation from the reservoir rock and the geofluid concentration. The non-steady-state model solves the partial differential equations describing radon transport under transient two-phase geothermal flow conditions. Radon concentrations of fluids from nine geothermal reservoirs showed strong correlations to the specific volume of the reservoir fluid. Lowest values were associated with all-liquid wells at Cerro Prieto, Wairakei, and Los Azufres reservoirs, and the highest values for ...

1986-01-01

143

Analytical study on integrity of BWR reactor internal structures against water hammer under RIA conditions  

Energy Technology Data Exchange (ETDEWEB)

The integrity of the RPV head and reactor internals was assessed by means of fluid-structural analyses using a coupled method to evaluate the water hammer phenomenon arising from high burnup fuel failure under RIA conditions. The fluid viscosity effect on the water column burst as well as the complex three-dimensional flow paths caused by a core shroud and standpipes were considered in this study. The three analysis scenarios were designed to investigate the above mentioned influential factors separately. In the first scenario, a two-dimensional axisymmetric reactor vessel model without any reactor internals was modeled to assess the influence of the fluid dynamics in the NSC RIA regulatory evaluation. This model has an actual RPV geometry and can be simply separated from other influential factors in order to concentrate only on investigation of the fluid viscosity effect. In the second scenario, a ...

2003-07-01

144

Economic analysis of proposed effluent limitations guidelines and standards for synthetic-based drilling fluids and other non-aqueous drilling fluids in the oil and gas extraction point source category  

Science.gov (United States)

The Economic Analysis (EA) report is written to address the impacts of this proposed Effluent Limitation Guidelines and Standards for Synthetic-Based and Other Non-Aqueous Drilling Fluids. Currently, effluent guidelines pertaining to the discharge of drilling fluids address two specific types of fluids: Oil-based drilling fluids (OBFs) that use diesel and mineral oil, which are prohibited from being discharged; and Water-based drilling Fluids (WBFs), which can be discharged subject to meeting certain discharge requirements, including a sheen test and an aqueous toxicity test, in certain limited offshore regions. Section Two presents sources of data, Section Three presents the industry profile, Section Four discusses the regulatory costs of options under consideration for the proposed rulemaking, and Section Five discusses the impacts of the proposed rule on firms, well drilling, and ...

1999-02-01

145

Diverter/bop system and method for a bottom supported offshore drilling rig  

Energy Technology Data Exchange (ETDEWEB)

A system is described adapted for alternative use as a diverter or a blowout preventer for a bottom supported drilling rig and adapted for connection to a permanent housing attached to rig structural members beneath a drilling rig rotary table, the permanent housing having an outlet connectable to a rig fluid system flow line. The system consists of: a fluid flow controller having a controller housing with a lower cylindrical opening and an upper cylindrical opening and a vertical path therebetween and a first outlet passage and a second outlet passage provided in its wall, a packing element disposed within the controller housing, and annular piston means adapted for moving from a first position to a second position, whereby in the first position the piston means wall prevents interior fluid from communicating with the outlet passages in the controller housing wall and in the second position the piston means wall allows ...

1986-07-01

146

Adsorption of argon on homogeneous graphitized thermal carbon black and heterogeneous carbon surface.  

Science.gov (United States)

In this paper we investigate the effects of surface mediation on the adsorption behavior of argon at different temperatures on homogeneous graphitized thermal carbon black and on heterogeneous nongraphitized carbon black surface. The grand canonical Monte Carlo (GCMC) simulation is used to study the adsorption, and its performance is tested against a number of experimental data on graphitized thermal carbon black (which is known to be highly homogeneous) that are available in the literature. The surface-mediation effect is shown to be essential in the correct description of the adsorption isotherm because without accounting for that effect the GCMC simulation results are always greater than the experimental data in the region where the monolayer is being completed. This is due to the overestimation of the fluid-fluid interaction between particles in the first layer close to the solid surface. It is the surface mediation that reduces this ...

2005-07-15

147

Thermal-fluid flow analysis and demonstration test of a spent fuel storage system  

Energy Technology Data Exchange (ETDEWEB)

Thermal-fluid flow analysis and demonstration test were performed for a spent fuel storage system. The commercial computational fluid dynamics (CFD) code, FLUENT was used for the numerical analysis. Effective thermal conductivities of a spent fuel assembly and a fuel basket were derived to optimize a thermal analysis model. Also, a porous model, which can simplify a complex configuration of a fuel assembly, was used in the thermal analysis. Demonstration test were performed to verify the thermal analysis method and procedure using a half scaled-down model and an electrically heated dummy fuel. The numerical analysis results were compared with the experimental data. Thermal analyses of the storage system were carried out for normal and off-normal conditions by using the verified analysis method.

2009-03-15

148

The structure of an active acoustic metamaterial with tunable effective density  

Energy Technology Data Exchange (ETDEWEB)

A new class of one-dimensional active acoustic metamaterials (AAMMs) with programmable effective densities is presented. The proposed AAMM is capable of producing densities that are orders of magnitudes lower or higher than the ambient fluid. Such characteristics are achieved by using an array of fluid cavities separated by piezoelectric diaphragms that are controlled to generate constant densities over wide frequency bands. The piezodiaphragms are augmented with passive electrical components to broaden the operating frequency bandwidth and enable densities higher than the fluid medium to be generated. The use of these components is shown to be essential to maintain the closed-loop compliance of the piezodiaphragm away from the zone of elastic instabilities. The values of the passive components are selected on a rational basis in order to ensure a balance between the frequency bandwidth and control voltage. With this unique ...

2009-12-15

149

The effects of temperature dependent viscosity and thermal conductivity on unsteady MHD convective heat transfer past a semi-infinite vertical porous moving plate with variable suction  

British Library Electronic Table of Contents (United Kingdom)

In this article, we studied the effects of variable viscosity and thermal conductivity on an unsteady two-dimensional laminar flow of a viscous incompressible conducting fluid past a semi-infinite vertical porous moving plate taking into account the effect of a magnetic field in the presence of variable suction. The fluid viscosity is assumed to vary as an inverse linear function of temperature but the thermal conductivity is assumed to vary as a linear function of temperature. It is assumed that the porous plate moves with a constant velocity in the direction of fluid flow, and the free stream velocity follows the exponentially increasing small perturbation law. The governing equations for the flow are transformed into a system of nonlinear ordinary differential equations by perturbation ...

2007-01-01

150

The composition-explicit distillation curve technique: Relating chemical analysis and physical properties of complex fluids  

British Library Electronic Table of Contents (United Kingdom)

The analysis of complex fluids such as crude oils, fuels, vegetable oils and mixed waste streams poses significant challenges arising primarily from the multiplicity of components, the different properties of the components (polarity, polarizability, etc.) and matrix properties. We have recently introduced an analytical strategy that simplifies many of these analyses, and provides the added potential of linking compositional information with physical property information. This aspect can be used to facilitate equation of state development for the complex fluids. In addition to chemical characterization, the approach provides the ability to calculate thermodynamic properties for such complex heterogeneous streams. The technique is based on the advanced distillation curve (ADC) metrology, wh...

2010-01-01

151

THE EFFECT OF VARIABLE THERMAL CONDUCTIVITY ON MICRO-POLAR FLUID FLOW BY CHEBYSHEV COLLOCATION METHOD  

British Library Electronic Table of Contents (United Kingdom)

In this article, the authors analyzed the effect of thermal conductivity on unsteady magnetohydrodynamic (MHD) free convection in a micro-polar fluid past a semi-infinite vertical porous plate. The fluid thermal conductivity is assumed to vary as a linear function of temperature. By using the Chebyshev collocation method in the spatial direction and the Crank-Nicolson method in the time direction, the boundary layer equations are transformed into a linear algebraic system. There are several material parameters whose affect on the flow have been studied, for instance, thermal conductivity, radiation, magnetic, micro-polar, suction (or injection) parameters, and Prandtl number. Boundary layer and Boussineq approximations have been introduced together to describe the flow field. The domain of...

2010-01-01

152

Novel reduced pressure-balance syringe for chromatographic analysis  

British Library Electronic Table of Contents (United Kingdom)

When withdrawing a fluid sample (for additional chromatographic analyses) from an apparatus operated at a reduced pressure, a typical syringe proves to be ineffective (even if it is equipped with a gas tight plunger). It simply does not create enough pressure differential to remove a fluid sample from a reduced pressure environment. We encountered such a situation as part of efforts to extend the operation of the advanced distillation curve protocol to reduced pressures. The problem was solved by the development of a pressure balance syringe that allows reliable and precise sampling from an apparatus operating at sub-ambient pressures. This new device uses an external vacuum source to evacuate a syringe barrel, allowing a user to withdraw fluid samples from environments with pressures as l...

2010-01-01

153

Nonlinear black-box models and force-sensorless damping control for damping systems using magneto-rheological fluid dampers  

British Library Electronic Table of Contents (United Kingdom)

In vibration control field, magneto-rheological (MR) fluid dampers are semi-active control devices that have recently begun to receive more attention. This paper presents a nonlinear black-box model (BBM) and an inverse black-box model (IBBM) for the identification of a MR fluid damper and their application to design a novel force-sensorless control method for any damping system using that damper. The nonlinear model named 'black-box' is a simple direct modeling method which was designed based on fuzzy-neural technique. Characteristics of the damper in study are directly estimated through a fuzzy mapping system. In order to improve the model accuracy, neural network technique including back-propagation and gradient descent method were used to train the fuzzy parameters to minimize the mode...

2011-01-01

154

Neurotoxicity and bony diseases caused by the continuous contamination with aluminum of solutions of renal dialysis  

International Nuclear Information System (INIS)

This article reviews the principal evidences about aluminum neurotoxicity in vitro, and some evidences in brain tissues of Alzheimer patients; and also show some studies realized with human that suffer renal deficiencies, dealing whit the principal osteodystrophy. The problem of analyzing low aluminum concentration in human fluids is overcome with very sensitive analytical methods as electrothermal atomic absorption spectrometry (ETAS) and voltammetric methods as Anodic Striping Voltammetry with complexing agents that easing adsorption over solid electrodes or mercury hanging drops. Is a vital question to know with accuracy the aluminum concentration in water used in hemodialysis or in fluids used in ambulatory peritoneal dialysis, as a first stage to prevent contamination by aluminum. So the prevention of contamination during sapling storage and analysis of biological fluids should be the first need and the sources of ...

2001-01-01

155

Ion processing element with composite media  

Energy Technology Data Exchange (ETDEWEB)

An ion processing element employing composite media disposed in a porous substrate, for facilitating removal of selected chemical species from a fluid stream. The ion processing element includes a porous fibrous glass substrate impregnated by composite media having one or more active components supported by a matrix material of polyacrylonitrile. The active components are effective in removing, by various mechanisms, one or more constituents from a fluid stream passing through the ion processing element. Due to the porosity and large surface area of both the composite medium and the substrate in which it is disposed, a high degree of contact is achieved between the active component and the fluid stream being processed. Further, the porosity of the matrix material and the substrate facilitates use of the ion processing element in high volume applications where it is desired to effectively process a high volume flows.

2009-03-24

156

Intrinsic fluorescence of the amniotic fluid  

International Nuclear Information System (INIS)

The intrinsic fluorescence of clear amniotic fluid from third-trimester pregnancy is reported. The fluorescence intensity peaked at 405 nm when excited by ultraviolet light in the range of 310 to 360 nm. All of the 33 samples tested fluoresced, and their emission spectrum had the same shape, varying only in magnitude. Changing sample temperature (20 to 50 C) and sample pH (7.2 to 7.7) had little effect on the emission spectrum. The same fluorescence, with higher intensity, was observed when some newborn urine was tested. The fluorescence of amniotic fluid may provide a new tool to determine fetal age, fetal organ maturation, and fetal distress. (author).

1981-01-01

157

In situ Raman spectroscopy investigation of bioactive glass reactivity: Simulated body fluid solution vs TRIS-buffered solution  

British Library Electronic Table of Contents (United Kingdom)

In the present contribution, the innovative in situ Raman micro-spectroscopy was applied to investigate the in vitro reactivity of various bioactive glasses. All the investigated glasses belonged to the Na2O\\K2O-CaO-P2O5-SiO2 system, but contained sensibly different percentages of network modifiers. The glasses were immersed for increasing times, up to 96h, in simulated body fluid (SBF) and in tris-buffered (TRIS) solution. In this way, two fundamental items were addressed, i.e. the effect of the glass composition and the nature of the soaking fluid on the overall reactivity. As regards the SBF, all the glasses were able to promote the formation of a hydroxyl-carbonate apatite (HCA) surface layer in very short times. The reaction rate was particularly quick for the 45S5 Bioglass and for it...

2011-01-01

158

Improvements in SCR systems  

Energy Technology Data Exchange (ETDEWEB)

Selective catalytic reduction (SCR) is a method of reducing the emissions of nitrogen oxides into the atmosphere. Peerless Manufacturing Co. specialises in designing and building SCR systems. The company uses fluid flow modelling to design systems, creating physical and/or numerical flow models to normalise the flow and eliminate potential problems. Computational fluid dynamics (CFD) is used to visualise fluid flow within SCR units and other types of equipment involving phase separators, air intake systems etc. An example is given of use of the commercial CFD code FLUENT to create a full-scale model of an SCR unit so its design could be modified for optimum performance. 1 fig., 1 photo.

2000-12-01

159

Electrorheological RayleighTaylor instability at the interface between a porous layer and thin shell with poorly conducting couple stress fluid  

British Library Electronic Table of Contents (United Kingdom)

This paper is concerned with the study of the Electrorheological RayleighTaylor instability (ERTI) at the interface between a densely packed saturated poorly conducting couple stress porous layer accelerated by a lighter poorly conducting couple stress fluid in a thin shell in the presence of a transverse electric field and laser radiation. A simple theory based on fully developed flow approximations is used to derive the dispersion relation for the growth rate of ERTI. The cutoff and the maximum wave numbers and the corresponding maximum frequencies are obtained. It is shown that the effects of couple stress parameter and the electric field reduce the growth rate considerably compared to a non-conducting fluid in the absence of an electric field. These are favorable to control the surface...

2011-01-01

160

Electrochemical characterization and CFD simulation of flow-assisted corrosion of aluminum alloy in ethylene glycol-water solution  

British Library Electronic Table of Contents (United Kingdom)

An impingement jet system was used to study flow-assisted corrosion (FAC) of 3003 aluminum (Al) alloy in ethylene glycol-water solutions that simulates the automotive coolant by corrosion potential and electrochemical impedance spectroscopy (EIS) measurements as well as computational fluid dynamics (CFD) simulation. The effects of solution pH and fluid impact angle on Al FAC were determined. An increase of solution pH enhances the activity of Al due to dissolution of Al oxide film in alkaline environment. Moreover, Al activity decreases with the increasing fluid impact angle to the specimen. A CFD simulation shows that, with the increase of impact angle, the electrode area under high-velocity flow field decreases and that under low-velocity flow field increases. Consequently, the shear str...

2008-01-01

161

Couple stress fluid improve rub-impact rotor-bearing system - Nonlinear dynamic analysis  

British Library Electronic Table of Contents (United Kingdom)

This study performs a dynamic analysis of the rub-impact rotor supported by two couple stress fluid film journal bearings. The strong nonlinear couple stress fluid film force, nonlinear rub-impact force and nonlinear suspension (hard spring) are presented and coupled together in this study. The displacements in the horizontal and vertical directions are considered for various non-dimensional speed ratios. The numerical results show that the dynamic behaviors of the system vary with the dimensionless speed ratios, the dimensionless unbalance parameters and the dimensionless parameter, l*. Inclusive of the periodic, sub-harmonic, quasi-periodic and chaotic motions are found in this analysis. The results of this study contribute to a further understanding of the nonlinear dynamics of a rotor-...

2010-01-01

162

Computerized pressure monitoring and control of Hydro-Quebec`s fluid-filled high-voltage underground cable network in Montreal  

Energy Technology Data Exchange (ETDEWEB)

The development and installation, by Hydro-Quebec, of a computerized pressure monitoring and control system on its fluid-filled high voltage underground cable network in Montreal, was described. The average age of these underground fluid-filled cables is more than 30 years and the cost to replace the circuits is estimated to be 230 million dollars. It is, therefore, crucial to maintain at all times and under all operating conditions a positive oil pressure in order to maintain the dielectric strength of paper insulation, and to prevent air and moisture from entering the cables and accessories. The monitoring and control system is reliable, flexible, user friendly and easy to upgrade. It reduces intervention time on the cables and ensures the protection of the cable network by remotely operating valves to connect oil reserve banks and by providing efficient maintenance management tools. 1 ref., 1 tab., 4 figs.

1996-08-01

163

Comparison of fluid-dynamic modeling of flow with velocity-encoded MR imaging  

International Nuclear Information System (INIS)

This paper develops a fluid dynamic model using finite difference methods characterizing flow in phantoms simulating in vivo conditions and to compare those results with velocity encoded MR images. The phantom consisted of 1-inch (2.5-cm) tubing with semicircular insert and fluid with viscosity, T1, and T2 comparable to blood. Numeric solutions to Navier-Stokes equations for this system were obtained using finite difference methods, with velocity input function of zero at walls and parabolic at both ends. In resulting color raster (CR) images, color temperature represented velocity value. In velocity-encoded MR images acquired under the same flow conditions, phase is proportional to average velocity during application of flow-encoding gradients. Because these gradients are applied along one direction per acquisition, magnitude and direction of velocity are obtained.

1990-11-25

164

Analysis of cerebrospinal fluid from chronic fatigue syndrome patients for multiple human ubiquitous viruses and xenotropic murine leukemia-related virus  

British Library Electronic Table of Contents (United Kingdom)

Abstract Recent reports showed many patients with chronic fatigue syndrome (CFS) harbor a retrovirus, xenotropic murine leukemia-related virus (XMRV), in blood; other studies could not replicate this finding. A useful next step would be to examine cerebrospinal fluid, because in some patients CFS is thought to be a brain disorder. Finding a microbe in the central nervous system would have greater significance than in blood because of the integrity of the blood-brain barrier. We examined cerebrospinal fluid from 43 CFS patients using polymerase chain reaction techniques, but did not find XMRV or multiple other common viruses, suggesting that exploration of other causes or pathogenetic mechanisms is warranted. Ann Neurol 2011;

2011-01-01

165

Tumor vascular permeability factor stimulates endothelial cell growth and angiogenesis.  

UK PubMed Central (United Kingdom)

Vascular permeability factor (VPF) is an Mr 40-kD protein that has been purified from the conditioned medium of guinea pig line 10 tumor cells grown in vitro, and increases fluid permeability from blood...Full Text Available

1989-11-01

166

Transmural distribution of extracellular purines in isolated guinea pig heart.  

UK PubMed Central (United Kingdom)

The purine adenosine appears to be involved in regulation of coronary vascular tone. Little is known concerning the levels and distribution of adenosine and related purines in the extracellular fluid...Full Text Available

1991-01-15

167

Time-dependent, finite, rotating universes  

International Nuclear Information System (INIS)

Three new classes of finite, homogeneous and nonsingular solutions of Einstein's equations which have time-dependent expansion, shear and rotation are presented. The t-constant sections are of Bianchi type IX. The source of these geometries is a fluid which has not been thermalized. (Author).

168

Time-dependent, Bianchi II, rotating universe  

International Nuclear Information System (INIS)

An exact cosmological solution of Einstein's equations which has time-dependent rotation is presented. The t-constant sections are of Bianchi type II. The source of this geometry is a fluid which has not been thermalized. (Author).

2006-11-03

169

Three-dimensional mise-a-la-masse modeling using horizontal well; Suihei kosei wo mochiita ryuden den`iho no sanjigen modeling  

Energy Technology Data Exchange (ETDEWEB)

The 3-D model program was developed to apply a mise-a-la-masse method to linear current sources with optional shapes. Mise-a-la-masse method is a bipolar mapping survey method using current sources installed in wells, and recently has been widely used for direct exploration of geothermal reservoirs. This method is also used for monitoring underground fluid as electrode arrangement of fluid flow tomography for surveying underground fluid (geothermal fluid, underground water, petroleum). In the geothermal reservoir exploration, the casing pipes of wells are used as linear current sources, and measured data are processed as those based on vertical current source. In the largely inclined well, the inclination of current sources should be considered. The 3-D modeling program was developed by difference calculus using the theoretical potential equation and apparent resistivity based on linear current sources ...

1996-10-01

170

The Effect of Age on the Gingival Crevicular Fluid Composition During Experimental Gingivitis. A Pilot Study  

UK PubMed Central (United Kingdom)

Background:Cytokines have been proposed as potentially useful diagnostic or prognostic markers of periodontal inflammation related alterations during the experimental gingivitis...Full Text Available

171

The Correlation and Accuracy of Glucose Levels between Interstitial Fluid and Venous Plasma by Continuous Glucose Monitoring System  

UK PubMed Central (United Kingdom)

BackgroundClinical experience with the continuous glucose monitoring systems (CGMS) is limited in Korea. The objective of this study is to evaluate the accuracy of the CGMS and the...Full Text Available

2010-12-01

172

Surfactant protein A, an innate immune factor, is expressed in the vaginal mucosa and is present in vaginal lavage fluid  

UK PubMed Central (United Kingdom)

Surfactant protein A (SP-A), first identified as a component of the lung surfactant system, is now recognized to be an important contributor to host defence mechanisms. SP-A can facilitate phagocytosis...Full Text Available

2004-01-01

173

Sulfate Reduction by a Desulfovibrio Species Isolated from Sheep Rumen1  

UK PubMed Central (United Kingdom)

Several dissimilatory, sulfate-reducing bacteria were isolated from the rumen fluid of sheep fed purified diets containing sulfate. One isolate, strain D, was selected for characterization. This organism...Full Text Available

1974-09-01

174

Structure of lipid bilayers  

UK PubMed Central (United Kingdom)

The quantitative experimental uncertainty in the structure of fully hydrated, biologically relevant, fluid (Lα) phase lipid bilayers has been too large to...Full Text Available

2000-11-10

175

Specificity of the anticollagenase action of tetracyclines: relevance to their anti-inflammatory potential.  

UK PubMed Central (United Kingdom)

The concentrations of doxycycline and 4-de-dimethylaminotetracycline required to inhibit 50% of collagenase activity were found to be 15 to 30 microM for human neutrophil and gingival crevicular fluid...Full Text Available

1992-01-01

176

Reinfusion of ascites during hemodialysis as a treatment of massive refractory ascites and acute renal failure  

UK PubMed Central (United Kingdom)

Refractory ascites can occur in patients with various conditions. Although several procedures based on the reinfusion of ascitic fluid have been reported after the failure of bed rest, salt and water...Full Text Available

177

Regulation of hyaluronan secretion into rabbit synovial joints in vivo by protein kinase C  

UK PubMed Central (United Kingdom)

Hyaluronan (HA) is important for joint cavitation, lubrication, volume regulation and synovial fluid drainage but little is known about the regulation of joint HA synthesis/secretion in vivo....Full Text Available

2003-07-15

178

Rapid aneuploidy detection with multiplex ligation-dependent probe amplification: a prospective study of 4000 amniotic fluid samples  

UK PubMed Central (United Kingdom)

The introduction of prenatal screening requires rapid high-throughput diagnosis of common aneuploidies. Multiplex ligation-dependent probe amplification (MLPA) allows for quick, easily automated multiplex...Full Text Available

2009-01-01

179

Prediction of critical properties of mixtures from the PRSV-2 equation of state: A correction for predicted critical volumes  

Energy Technology Data Exchange (ETDEWEB)

Critical properties of a fluid or fluid mixtures are important for describing fluid phase behavior, predicting physical properties, developing equations of state, and designing supercritical-fluid extraction processes, and compression and refrigeration units. The predictive capability of the Peng-Robinson-Styjek-Vera (PRSV-2) equation of state (1986) for critical properties of binary mixtures was investigated. The procedure adopted by Heidemann and Khalil (1980) and discussed by Abu-Eishah et al. (1998) was followed. An optimized value for the binary interaction parameter based on minimization of error between experimental and predicted critical temperatures was used. The standard and the average of the absolute relative deviations in critical properties are included. The predicted critical temperature and pressure for several nonpolar and polar systems agree well with experimental data and are always ...

1999-09-01

180

Poisonous snakebite in central Texas. Possible indicators for antivenin treatment.  

UK PubMed Central (United Kingdom)

Sixty-seven patients hospitalized for poisonous snakebite between 1975 and 1990 were managed by elevation, tetanus prophylaxis, intravenous fluids and antibiotics, and often by a limited excision of...Full Text Available

1991-05-01

181

Plasma Treatment within Dielectric Fluids.  

Science.gov (United States)

A dielectric liquid having entrained bubbles of gas or vapor is subjected to an electric field applied between spaced electrodes (112, 116) which generates microdischarges (and thus plasma) within the bubbles, allowing modification of the properties of th...

2003-01-01

182

Numerical simulations of industrial processes involving fluid dynamics, combustion and radiation  

Energy Technology Data Exchange (ETDEWEB)

Moving out of the scientific community research laboratories, computational fluid dynamics (CFD) software packages are now allowing industrials to analyse and optimize industrial processes involving the use of gases, liquids and even some two-phase fluids. Their attractiveness and their impact stems out from the opportunity they offer to bring insight into an existing unit, or even at the design stage, by displaying the spatial distribution of process relevant variables such as temperature, concentration. The filling of the spacing in between a two-layer window is a simple example. This new opportunity of visualisation is at times an unique way, when the process environment is an opaque one, such as liquid metal flowing into a tundish or when measurements of flows may be a long and tedious work, such as flows within water treatment basins. This environment we are to investigate in order to optimize can also be a harsh one, due to its high ...

1997-12-31

183

Numerical modeling of slug flow initiation in a horizontal channels using a two-fluid model  

International Nuclear Information System (INIS)

This paper presents a methodology for modeling slug initiation and growth in horizontal ducts. Transient two-fluid equations are solved numerically using a class of high-resolution shock capturing methods. The advantage of this method is that slug formation and growth in a stratified regime can be calculated directly from the solutions to the flow field differential equations. In addition, by using high-resolution shock capturing methods that do not contain numerical diffusion, the discontinuity generated by slugging in the flow field can be modeled with good accuracy. The two-fluid model is shown to be well-posed mathematically only under certain conditions. Under these circumstances, the two-fluid model is capable of correctly predicting and modeling the flow physics. When ill-posed, an unbounded instability occurs in the flow field solution, and the instability amplitude increases exponentially with decreasing mesh ...

2011-02-01

184

MULTITARGETED THERAPY OF CANCER BY GREEN TEA POLYPHENOLS  

UK PubMed Central (United Kingdom)

Tea ranks second only to water as a major component of fluid intake worldwide and has been considered a health-promoting beverage since ancient times. For the past two decades, we and others...Full Text Available

2008-10-08

185

Legionella tucsonensis sp. nov. isolated from a renal transplant recipient.  

UK PubMed Central (United Kingdom)

A Legionella-like organism (strain 1087-AZ-H) was isolated from a pleural-fluid specimen from a renal transplant patient undergoing immunosuppressive therapy. Growth characteristics and gas-liquid chromatography...Full Text Available

1989-08-01

186

Interactive Cytokine Regulation of Synoviocyte Lubricant Secretion  

UK PubMed Central (United Kingdom)

Cytokine regulation of synovial fluid (SF) lubricants, hyaluronan (HA), and proteoglycan 4 (PRG4) is important in health, injury, and disease of synovial joints, and may also provide powerful regulation...Full Text Available

2010-04-01

187

In-vivo coronary flow profiling based on biplane angiograms: influence of geometric simplifications on the three-dimensional reconstruction and wall shear stress calculation  

UK PubMed Central (United Kingdom)

BackgroundClinical studies suggest that local wall shear stress (WSS) patterns modulate the site and the progression of atherosclerotic lesions. Computational fluid dynamics (CFD)...Full Text Available

188

Immunoradiometric measurement of the factor VIII procoagulant antigen.  

UK PubMed Central (United Kingdom)

A fluid-phase immunoradiometric assay has been developed which identifies an antigen on the Factor VIII (antihemophilic factor) procoagulant protein. This sensitive and quantitative assay is not influenced...Full Text Available

1978-11-01

189

Hyperoxia enhances VEGF release from A549 cells via post-transcriptional processes  

UK PubMed Central (United Kingdom)

Exposure of animals to hyperoxia decreases lung VEGF mRNA expression concomitant with an acute increase in VEGF protein within the epithelial lining fluid (ELF). The VEGF concentration in ELF...Full Text Available

2007-09-01

190

Hydrodynamic studies of post dryout two-phase downflow in narrow channels  

Energy Technology Data Exchange (ETDEWEB)

An experimental study of the hydrodynamics of a narrow channel was performed in order to obtain the heat transfer mechanisms and influences contributing to the flow regime transition from inverted annular to inverted slug flows for post dryout downflow. The experimental series consisted of both adiabatic and diabatic visualization tests over a wide range of fluid and thermal parameters. The system inlet gas velocities ranged from 0 to 14 meters per second while the inlet fluid velocities ranged from 1 to 3 meters per second. Full extent visualization of the flow regime was possible due to a quartz tube in tube construction with a clear heating fluid. Constant temperature heating of the freon was accomplished at bulk fluid temperatures above the critical heat flux temperature. For each hydrodynamic flow condition, one to three minuets of VHS-video filming was performed to acquire both flow regime and ...

1995-07-01

191

High Shear Stress at the Surface of Enhancing Plaque in the Systolic Phase is Related to the Symptom Presentation of Severe M1 Stenosis  

UK PubMed Central (United Kingdom)

The computational fluid dynamics methods for the limited flow rate and the small dimensions of an intracranial artery stenosis may help demonstrate the stroke mechanism in intracranial atherosclerosis....Full Text Available

2011-07-01

192

Functional properties of membrane cofactor protein of complement.  

UK PubMed Central (United Kingdom)

Membrane cofactor protein (MCP or gp45-70) of the complement system is a cofactor for factor I-mediated cleavage of fluid-phase C3b and C3b-like C3, which opens the thioester bond. In the present study...Full Text Available

1989-12-01

193

Experimental evaluation of a non-azeotropic working fluid for geothermal heat pump system  

Energy Technology Data Exchange (ETDEWEB)

Geothermal energy resources are found in many countries. A reasonable and efficient utilization of these resources has been a worldwide concern. The application of geothermal heat pump systems (GHPS) can help increase the efficiency of using geothermal energy and reduce the thermal pollution to the earth surface. However, this is only possible with a proper working fluid. In this paper, a non-azeotropic working fluid (R290/R600a/R123) is presented for a GHPS where geothermal water at 40-45{sup o}C and heating network water at 70-80{sup o}C serve as the low and high temperature heat sources. Experimental results show that the coefficient of performance (COP) of a GHPS using the working fluid is above 3.5 with the condensation temperature above 80{sup o}C and the condensation pressure below 18 bar, while the temperature of the geothermal water is reduced from 40-46{sup o}C to 31-36{sup o}C. (author)

2004-06-01

194

Experimental evaluation of a non-azeotropic working fluid for geothermal heat pump system  

International Nuclear Information System (INIS)

Geothermal energy resources are found in many countries. A reasonable and efficient utilization of these resources has been a worldwide concern. The application of geothermal heat pump systems (GHPS) can help increase the efficiency of using geothermal energy and reduce the thermal pollution to the earth surface. However, this is only possible with a proper working fluid. In this paper, a non-azeotropic working fluid (R290/R600a/R123) is presented for a GHPS where geothermal water at 40-45 deg. C and heating network water at 70-80 deg. C serve as the low and high temperature heat sources. Experimental results show that the coefficient of performance (COP) of a GHPS using the working fluid is above 3.5 with the condensation temperature above 80 deg. C and the condensation pressure below 18 bar, while the temperature of the geothermal water is reduced from 40-46 deg. C to 31-36 deg. C.

2004-06-01

195

Endothelin-1 Is Increased in Cerebrospinal Fluid and Associated with Unfavorable Outcomes in Children after Severe Traumatic Brain Injury  

UK PubMed Central (United Kingdom)

AbstractSevere pediatric traumatic brain injury (TBI) is associated with unfavorable outcomes secondary to injury from activation of the inflammatory cascade, the release of excitotoxic...Full Text Available

2010-10-01

196

Effects of cyclooxygenase inhibitors on the alterations in lung mechanics caused by endotoxemia in the unanesthetized sheep.  

UK PubMed Central (United Kingdom)

The effects of Escherichia coli endotoxin on lung mechanics, hemodynamics, gas exchange, and lung fluid and solute exchange were studied in 12 chronically instrumented unanesthetized sheep. A possible...Full Text Available

1983-07-01

197

Effects of Sildenafil and Tadalafil on Intraocular Pressure in Sheep: Implications for Aqueous Humor Dynamics  

UK PubMed Central (United Kingdom)

Purpose.To determine the effects of vasodilators on intraocular pressure (IOP) and the protein content of sheep aqueous humor (AH), because the vasodilators may increase fluid leakage...Full Text Available

2010-06-01

198

Effect of surface-perturbed intermolecular interaction on adsorption of simple gases on a graphitized carbon surface.  

Science.gov (United States)

In this paper, we investigate the effect of the solid surface on the fluid-fluid intermolecular potential energy. This modified fluid-fluid interaction energy due to the inducement of a solid surface is used in the grand canonical Monte Carlo (GCMC) simulation of various noble gases, nitrogen, and methane on graphitized thermal carbon black. This effect is such that the effective interaction potential energy between two particles close to surface is less than the potential energy if the solid substrate is not present. With this modification the GCMC simulation results agree extremely well with the experimental data over a wide range of pressures while the simulation results with the unmodified potential energy give rise to a shoulder near the neighborhood of monolayer coverage and the significant overprediction of the second and higher layer coverages. In particular the unmodified GCMC results exhibit very sharp change in those higher layers ...

2004-08-31

199

Dosing Recommendations for Continuous Venovenous Hemodiafiltration with AN69 Filter Membranes and Prismaflex Dialyzers  

UK PubMed Central (United Kingdom)

Background:Continuous renal replacement therapy is used to manage fluid and solute imbalances in critically ill patients but may affect the clearance of concurrently administered...Full Text Available

2009-11-01

200

Differential expression of Haemophilus parasuis genes in response to iron restriction and cerebrospinal fluid  

UK PubMed Central (United Kingdom)

Haemophilus parasuis is an important opportunistic pathogen in swine of high health status, but to date no proven virulence factors have been described. As virulence factors are known...Full Text Available

2007-07-01

201

Detection of Sub-Clinical CWD Infection in Conventional Test-Negative Deer Long after Oral Exposure to Urine and Feces from CWD+ Deer  

UK PubMed Central (United Kingdom)

BackgroundChronic wasting disease (CWD) of cervids is a prion disease distinguished by high levels of transmissibility, wherein bodily fluids and excretions are thought to play an...Full Text Available

202

Consistency in potency assay of tetanus toxoid in mice  

UK PubMed Central (United Kingdom)

The use of mice for the assay of tetanus toxoids would offer considerable advantages over the use of guinea-pigs, but mice cannot readily be immunized with the fluid tetanus toxoid at present designated...Full Text Available

1959-01-01

203

Chemical refining of coal (Report on ECSC contract 7220-EC/816)  

Energy Technology Data Exchange (ETDEWEB)

Three areas have been investigated: coal liquefaction with supercritical fluids, liquefaction by extraction with high boiling liquid solvents, and the production of resins from coal-derived hydrocarbons. The processes are described.

1983-01-01

204

Changes in inflammatory mediators in experimental periodontitis in the rhesus monkey.  

UK PubMed Central (United Kingdom)

Ligature-induced periodontitis was monitored for 6 months in eight Macaca mulatta monkeys to examine clinical status, radiographic bone level, and crevicular fluid (CF) levels of prostaglandin E2 (PGE2),...Full Text Available

1993-04-01

205

Cerebrospinal fluid zinc concentrations in febrile convulsions.  

UK PubMed Central (United Kingdom)

Zinc modulates the activity of glutamic acid decarboxylase, the rate limiting enzyme in the synthesis of gamma-aminobutyric acid (GABA), which is a major inhibitory neurotransmitter. Low cerebrospinal...Full Text Available

1995-10-01

206

CXCL12-Mediated Guidance of Migrating Embryonic Stem Cell-Derived Neural Progenitors Transplanted into the Hippocampus  

UK PubMed Central (United Kingdom)

Stem cell therapies for neurodegenerative disorders require accurate delivery of the transplanted cells to the sites of damage. Numerous studies have established that fluid injections to the hippocampus...Full Text Available

207

Biopersistence of nonfibrous mineral particles in the respiratory tracts of subjects following occupational exposure.  

UK PubMed Central (United Kingdom)

Transmission electron microscopy analysis (TEMA) was used to analyze the bronchoalveolar lavage fluid (BALF) of 262 subjects occupationally exposed (OE) to nonfibrous mineral particles (NFMP) and 42...Full Text Available

1994-10-01

208

Analyses of mixed-hydrocarbon binary thermodynamic cycles for moderate-temperature geothermal resources using regeneration techniques  

Energy Technology Data Exchange (ETDEWEB)

Studies of basic binary geothermal cycles utilizing mixtures of hydrocarbons have shown better performance than for pure fluids for a moderate temperature (360/sup 0/F) resource. However, a loss is net geofluid effectiveness (watt-hours net plant output/1bm geofluid) results when the geofluid outlet temperature is limited to temperatures in excess of 160/sup 0/F to alleviate a silica precipitation problem. This study examined three working fluids consisting of binary mixtures of hydrocarbons to see if use of regenerative preheating techniques such as turbine exhaust recupation and/or turbine bleed could recover the loss in geofluid effectiveness for a 160/sup 0/F geofluid outlet temperature. Results showed that with the most promising of the three working fluids a turbine exhaust recuperator alone is sufficient to recover all the lost effectiveness while maintaining the geofluid outlet temperature at 160/sup 0/F. A brief ...

1981-12-01

209

Analyses of mixed-hydrocarbon binary thermodynamic cycles for moderate-temperature geothermal resources  

Energy Technology Data Exchange (ETDEWEB)

A number of binary geothermal cycles utilizing mixed hydrocarbon working fluids were analyzed with the overall objective of finding a working fluid which can produce low-cost electrical energy using a moderately-low temperature geothermal resource. Both boiling and supercritical shell-and-tube cycles were considered. The performance of a dual-boiling isobutane cycle supplied by a 280/sup 0/F hydrothermal resource (corresponding to the 5 MW pilot plant at the Raft River site in Idaho) was selected as a reference. To investigate the effect of resource temperature on the choice of working fluid, several analyses were conducted for a 360/sup 0/F hydrothermal resource, which is representative of the Heber resource in California. The hydrocarbon working fluids analyzed included methane, ethane, propane, isobutane, isopentane, hexane, heptane, and mixtures of those pure hydrocarbons. For comparison, two ...

1981-02-01

210

Analyses of mixed hydrocarbon binary thermodynamic cycles for moderate temperature geothermal resources using regeneration techniques  

Energy Technology Data Exchange (ETDEWEB)

Studies have shown that binary geothermal cycles utilizing mixed-hydrocarbon working fluids can result in better performance than those utilizing pure fluids for moderate temperature (360F) resources. However, a loss in net geofluid effectiveness results when the geofluid outlet is limited to temperatures in excess of 160F to alleviate potential silica precipitation. This study examined three mixed-hydrocarbon working fluids to see if use of regenerative preheating techniques such as turbine exhaust recuperation and/or turbine bleed could recover this loss. Results showed that with the most promising of the three working fluids, a turbine-exhaust recuperator alone is sufficient to recover all the lost effectiveness while maintaining the geofluid outlet temperature at 160F. A brief study to investigate cold weather operation with the recuperator showed no major detrimental response of the system; ...

1982-08-01

211

Activation of peripheral blood mononuclear cells in bronchoalveolar lavage fluid from patients with sarcoidosis: visualisation of single cell activation products.  

UK PubMed Central (United Kingdom)

BACKGROUND--Interstitial lung diseases are characterised by the recruitment of mononuclear cells to disease sites where maturation occurs and activation products, including lysozyme (LZM), are released....Full Text Available

1994-11-01

212

A study of light hydrocarbons (C{sub 4}-C{sub 1}3) in source rocks and petroleum fluid  

Energy Technology Data Exchange (ETDEWEB)

This thesis consists of an introduction and five included papers. Of these, four papers are published in international journals and the fifth was submitted for review in April 2000. Emphasis has been placed on both naturally and artificially generated light hydrocarbons in petroleum fluids and their proposed source rocks as well as direct application of light hydrocarbons to oil/source rock correlations. Collectively, these papers describe a strategy for interpreting the source of the light hydrocarbons in original oils and condensates as well as the source of the asphaltene fractions from the reservoir fluids. The influence of maturity on light hydrocarbon composition has also been evaluated. The papers include (1) compositional data on the light hydrocarbons from thermal extracts and kerogen pyrolysates of sediment samples, (2) light hydrocarbon data of oils and condensates as well as the pyrolysis products of the asphaltenes from these ...

2000-07-01

213

A non-invasive technique for standing surgical repair of urinary bladder rupture in a post-partum mare: a case report  

UK PubMed Central (United Kingdom)

An 11-year-old mare presented 36 hours after foaling with a ruptured bladder. Uroperitoneum was diagnosed on ultrasound and from the creatinine concentration of the peritoneal fluid. Bladder endoscopy...Full Text Available

214

4 - NASA Technical Reports Server  

Science.gov (United States)

Mar 1, 2011 ... The movement of hydrothermal fluids and/or fumarolic vapors through local rocks prior ... The Solar Energetic Particle Event of December 14, 2006 .... for measurement of non-precipitating cloud hydrometeors and aerosols, ...

215

Use of the K88 antigen for in vivo bacterial competition with porcine strains of enteropathogenic Escherichia coli.  

Science.gov (United States)

Infant mice were used to measure the amount of fluid accumulation (enterosorption) in the intestinal tract after oral inoculation of a porcine strain of enteropathogenic Escherichia coli (K88-+, Ent-+). Significant reduction in the amount of fluid found in the intestinal tract was observed if the mice were first inoculated with a K88-possessing, non-enterotoxigenic strain of E. coli. The protection provided is thought to be due to specific competition for attachment sites on cells of the small intestine. PMID:1095492

1975-07-01

216

The effect of flow velocity on pitting corrosion and stress corrosion cracking of reactor materials  

International Nuclear Information System (INIS)

This paper describes two research programs which are currently underway in the author's laboratory to investigate the effect of fluid flow on the degradation of power plant materials in high temperature/high pressure aqueous environments. These programs include the design and operation of a controlled hydrodynamic corrosion testing apparatus that can be used to study the general and localized corrosion characteristics of alloys in simulated nuclear reactor environments, and a study of the effect of flow velocity on the stress corrosion cracking of ASTM A508 C1.2 steel and Type 304SS in simulated BWR heat transport fluids.

217

Simulation of Pulsed Neutron Activation using a CFD code  

International Nuclear Information System (INIS)

Tests for the applicability of a CFD (Computational Fluid Dynamics) code for simulating activity transport in PNA (Pulsed Neutron Activation) fluid measurements have been performed. The CFD code was combined with a Monte Carlo code used for the calculation of the initial activity distribution. The results from the calculations show that it is possible to use CFD for calculation of the activity distribution in PNA. The mainly qualitative results in this work are encouraging and suggest further work. In the continuation of this work a response function for the gamma detector will be calculated so that a PNA time spectrum can be simulated. A more accurate comparison with experimental data can then be performed

2008-09-14

218

Report of the Fluid Dynamics Panel Working Group 10 on calculation of 3D separate turbulent flows in boundary layer limit  

Science.gov (United States)

The results of a study conducted by Working Group 10 of the AGARD Fluid Dynamics Panel to investigate the limits of boundary layer methods, both the integral and field type formulations, for calculating three-dimensional turbulent separated flow are presented. Test cases used to assess the boundary layer calculations included the DFLVR prolate spheroid at angle of attack and the NASA-Ames Wing C. Comparisons between boundary layer calculations and experimental data are presented for these test cases along with observations, conclusions, and recommendations.

1990-05-01

219

Peristaltic flow of a couple stress fluid under the effect of induced magnetic field in an asymmetric channel  

Energy Technology Data Exchange (ETDEWEB)

The present paper investigates the peristaltic transport of a couple stress fluid in an asymmetric channel with the effect of the induced magnetic field. The exact solutions of momentum and the magnetic field equations have been calculated under the assumptions of long wave length and low but finite Reynolds number. The expression for pressure rise has been computed numerically using mathematics software Mathematica. The graphical results have been presented to discuss the physical behavior of various physical parameters of interest. Finally, the trapping phenomena have been discussed for various physical parameters. (orig.)

2011-01-15

220

Peristaltic flow of a couple stress fluid under the effect of induced magnetic field in an asymmetric channel  

British Library Electronic Table of Contents (United Kingdom)

The present paper investigates the peristaltic transport of a couple stress fluid in an asymmetric channel with the effect of the induced magnetic field. The exact solutions of momentum and the magnetic field equations have been calculated under the assumptions of long wave length and low but finite Reynolds number. The expression for pressure rise has been computed numerically using mathematics software Mathematica. The graphical results have been presented to discuss the physical behavior of various physical parameters of interest. Finally, the trapping phenomena have been discussed for various physical parameters.

2011-01-01

221

Peristaltic flow of a couple stress fluid in an annulus: Application of an endoscope  

Science.gov (United States)

This paper discusses the influence of an endoscope on the peristaltic flow of a couple stress fluid in an annulus under a zero Reynolds number and long wavelength approximation. The inner tube is uniform, rigid, while the outer tube has a sinusoidal wave traveling down its wall. Analytical expressions for the axial velocity, stream function and axial pressure gradient are established. The flow is investigated in a wave frame of reference moving with the velocity of the wave. Numerical calculations are carried out for the pressure rise, frictional forces and trapping. The features of the flow characteristics are analyzed by plotting graphs and discussed in detail.

2008-04-01

222

Organometallic Polymer Coatings for Geothermal-Fluid-Sprayed Air-Cooled Condensers: Preprint  

Energy Technology Data Exchange (ETDEWEB)

Researchers are developing polymer-based coating systems to reduce scaling and corrosion of air-cooled condensers that use a geothermal fluid spray for heat transfer augmentation. These coating systems act as barriers to corrosion to protect aluminum fins and steel tubing; they are formulated to resist the strong attachment of scale. Field tests have been done to determine the corrosion and scaling issues related to brine spraying and a promising organometallic polymer has been evaluated in salt spray tests.

2002-08-01

223

Modeling of feed water check valves using RELAP5; Modellierung von Speisewasserrueckschlagventilen in RELAP5  

Energy Technology Data Exchange (ETDEWEB)

Westinghouse Electric Germany GmbH has developed fluid dynamic models for medium-actuated armatures using the thermal hydraulic code RELAP5 in order to reach a more realistic description of the armature behavior including fluid-structure interactions in case of transient flow conditions in piping systems. The contribution is concerned with the modeling of damped check valves. The model allows the description of the behavior during opening and closure of a check armature. The calculated results show good agreement with the available measured data.

2009-07-01

224

Magneto thermal convection in a compressible couple-stress fluid  

Energy Technology Data Exchange (ETDEWEB)

The problem of thermal instability of compressible, electrically conducting couple-stress fluids in the presence of a uniform magnetic field is considered. Following the linearized stability theory and normal mode analysis, the dispersion relation is obtained. For stationary convection, the compressibility, couple-stress, and magnetic field postpone the onset of convection. Graphs have been plotted by giving numerical values of the parameters to depict the stability characteristics. The principle of exchange of stabilities is found to be satisfied. The magnetic field introduces oscillatory modes in the system that were non-existent in its absence. The case of overstability is also studied wherein a sufficient condition for the non-existence of overstability is obtained. (orig.)

2010-03-15

225

Industrial processing of complex fluids: Formulation and modeling  

Energy Technology Data Exchange (ETDEWEB)

The production of many important commercial materials involves the evolution of a complex fluid through a cooling phase into a hardened product. Textile fibers, high-strength fibers(KEVLAR, VECTRAN), plastics, chopped-fiber compounds, and fiber optical cable are such materials. Industry desires to replace experiments with on-line, real time models of these processes. Solutions to the problems are not just a matter of technology transfer, but require a fundamental description and simulation of the processes. Goals of the project are to develop models that can be used to optimize macroscopic properties of the solid product, to identify sources of undesirable defects, and to seek boundary-temperature and flow-and-material controls to optimize desired properties.

1997-08-01

226

Heat generation of magneto-rheological fluid dampers  

Science.gov (United States)

This study presents a theoretical analysis of heat generation and dissipation of field-controllable magneto-rheological fluid (MRF) shock absorbers. Since MRF dampers are energy- dissipating devices, the issues of heat generation and dissipation are important in predicting their performance. A theoretical model is developed based on Bingham plastic model to estimate temperature history of the MRF dampers. The governing equation includes the MRF viscosity as a function of the temperature. The numerical solutions are compared with experimental results in order to validate the accuracy of the model, and excellent agreements are obtained.

2000-04-01

227

Experimental study on fuzzy logic vibration control of a bridge using fail-safe magnetorheological fluid dampers  

Science.gov (United States)

This study presents a semi-active vibration control of a scaled two-span bridge structure. Magneto-rheological fluid dampers are utilized as the semi-active energy absorbing devices, and a bridge vibration control system is developed. Closed-loop control system based on fuzzy logic is used to suppress the bridge deck motion under random excitation. It is demonstrated that this fuzzy logic control system can significantly reduce the relative deck displacement using about 60% less power compared to passive on state, while the absolute deck acceleration remains practically unchanged.

2001-07-01

228

Core preservation with a laminated, heat-sealed package  

Energy Technology Data Exchange (ETDEWEB)

A core preservation package was developed to maintain the reservoir characteristics of core samples and consequently to improve the quality of data obtained through laboratory core analyses. The package is a heat-sealable plastic-aluminum laminate similar to those common in the food-packaging industry. The laminated core preservation package acts as an impermeable barrier to water vapor and gases, and is resistant to chemical alteration and degradation by core fluids. These performance characteristics result in effective core preservation by maintaining the fluid content of the core. Other advantages of the laminated package are that it is fast and simple to use and eliminates the cumbersome dip-coat step used in some core preservation methods.

1988-12-01

229

Convection in the cavity between two rollers: The effect of thermal boundary conditions  

Energy Technology Data Exchange (ETDEWEB)

In this study the authors examine the convective cooling provided by fluid trapped in the cavity between two consecutive rollers in a roller bearing. In order to calculate the steady-state temperature of the roller, the designer must know nor only the rolling-contact heat input received by the roller but also the convection cooling effect of the surrounding fluid. Until recently, this lateral convection cooling effect was modeled by assuming a certain (constant) heat transfer coefficient h at the roller surface, and then calculating the steady-state temperature distribution around the roller.

1991-02-01

230

An investigation of turbulent convection heat transfer performance in spiral spring coil inserted tubes  

International Nuclear Information System (INIS)

This paper presents the results of the experimental investigation on heat transfer and fluid friction characteristics of a class of spiral spring coil used as a tube side forced convection heat transfer augmentation devices. Based on a lot of experimental data, the heat transfer correlation and fluid friction correlation revised by temperature were reached in terms of linear regression. At the same time, proper criteria were used to evaluate the economic performance of the spiral spring inserted tube according to the demand of practical application and some probing analysis were made.

1996-01-01

231

State-of-the-art review of computational fluid dynamics modeling for fluid-solids systems  

Energy Technology Data Exchange (ETDEWEB)

As the result of 15 years of research (50 staff years of effort) Argonne National Laboratory (ANL), through its involvement in fluidized-bed combustion, magnetohydrodynamics, and a variety of environmental programs, has produced extensive computational fluid dynamics (CFD) software and models to predict the multiphase hydrodynamic and reactive behavior of fluid-solids motions and interactions in complex fluidized-bed reactors (FBRS) and slurry systems. This has resulted in the FLUFIX, IRF, and SLUFIX computer programs. These programs are based on fluid-solids hydrodynamic models and can predict information important to the designer of atmospheric or pressurized bubbling and circulating FBR, fluid catalytic cracking (FCC) and slurry units to guarantee optimum efficiency with minimum release of pollutants into the environment. This latter issue will become of paramount importance with the enactment of the ...

1994-05-12

232

Nanoparticle arrays formed by spatial compartmentalization in a complex fluid.  

Energy Technology Data Exchange (ETDEWEB)

A mesoscopically ordered lamellar gel phase of a polymer-grafted, lipid-based complex fluid is used as a scaffolding to spatially organize inorganic nanoparticles. The complex fluid provides both a highly anisotropic environment and a segregated aqueous and organic domains in which inorganic nanoparticles can be selectively placed by tailoring their size and surface characteristics. Three types of silver nanoparticles -- underivatized, surfactant-stabilized, and dodecanthiol-derivatized -- were evaluated. Comparison of the surface plasmon resonance of the various silver particles dispersed in conventional solvents to those contained within the complex fluid was used to determine the region of spatial localization in the lamellar gel phase. Silver particles rendered hydrophobic by capping with an alkane thiol insert into the hydrocarbon bilayer region. Surfactant-stabilized and underivatized silver nanoparticles reside in ...

2001-03-14

233

Metal Nanoparticles Preparation In Supercritical Carbon Dioxide Solutions  

Energy Technology Data Exchange (ETDEWEB)

The novel optical, electronic, and/or magnetic properties of metal and semiconductor nanoparticles have resulted in extensive research on new methods for their preparation. An ideal preparation method would allow the particle size, size distribution, crystallinity, and particle shape to be easily controlled, and would be applicable to a wide variety of material systems. Numerous preparation methods have been reported, each with its inherent advantages and disadvantages; however, an ideal method has yet to emerge. The most widely applied methods for nanoparticle preparation include the sonochemical reduction of organometallic reagents,(1&2) the solvothermal method of Alivisatos,(3) reactions in microemulsions,(4-6) the polyol method (reduction by alcohols),(7-9) and the use of polymer and solgel materials as hosts.(10-13) In addition to these methods, there are a variety of methods that take advantage of the unique properties of a supercritical fluid.(14&15) ...

2004-04-01

234

Comparative adequacy of conventional radiography, ultrasonography and Computed Tomography in twenty-six consecutive patients with acute superior mesenteric ischemia  

International Nuclear Information System (INIS)

Ischemic bowel disease is a rare disorder whose incidence is increasing as the mean age of the population increases. Diagnosis by clinical, laboratory and radiologic means is often difficult, and delay in definitive therapy results in substantial morbidity and mortality. A series of 26 consecutive patients, with proved acute superior mesenteric ischemia, was retrospectively reviewed: the authors reports the diagnostic methods performed preoperatively, the site and the cause of infarction and the time passed between the first radiograph and surgery. Plain abdominal radiographs were performed in 25 of 26 patients, screening abdominal US in 23 cases and CT in 19 cases. All radiological examinations were retrospectively reviewed by the three authors, independently, to recognize the different signs of infarction. On plain abdominal films, the findings warranting a presumptive diagnosis of bowel infarction were air-fluid levels (84% of cases), dilated bowel loops (48%), ...

1997-01-01

235

Analyses of mixed hydrocarbon binary thermodynamic cycles for moderate temperature geothermal resources  

Energy Technology Data Exchange (ETDEWEB)

A number of binary geothermal cycles utilizing mixed hydrocarbon working fluids were analyzed with the overall objective of finding a working fluid which can produce low-cost electrical energy using a moderately low temperature geothermal resource. Both boiling and supercritical shell-and-tube cycles were considered. The performance of a dual-boiling isobutane cycle supplied by a 280/sup 0/F hydrothermal resource (corresponding to the 5MW pilot plant at the Raft River site in Idaho) was selected as a reference. To investigate the effect of resource temperature on the choice of working fluid, several analyses were conducted for a 360/sup 0/F hydrothermal resource, which is representative of the Heber resource in California. The hydrocarbon working fluids analyzed included methane, ethane, propane, isobutane, isopentane, hexane, heptane, and mixtures of those pure hydrocarbons. For comparison, two ...

1981-01-01

236

Advanced Binary Geothermal Power Plancts Working Fluid Property Determination and Heat Exchanger Design  

Energy Technology Data Exchange (ETDEWEB)

The performance of binary geothermal power plants can be improved through the proper choice of a working fluid, and optimization of component designs and operating conditions. This paper reviews the investigations at the Idaho National Engineering Laboratory (INEL) which are examining binary cycle performance improvements: for moderate temperature (350 to 400 F) resources with emphasis on how the improvements may be integrated into design of binary cycles. These investigations are examining performance improvements resulting from the supercritical vaporization of mixed hydrocarbon working fluids and achieving countercurrent integral condensation with these fluids, as well as the modification of the turbine inlet state points to achieve supersaturated turbine vapor expansions. For resources where the brine outlet temperature is restricted, the use of turbine exhaust recuperators is examined. The baseline plant used to ...

1989-03-21

237

A Scheme of 3-D Breakdown-whip Analysis Methodology for High Energy Piping  

Energy Technology Data Exchange (ETDEWEB)

High energy piping systems are operated with either or both conditions of maximum operating temperature exceeding 200 .deg. F(93.3 .deg. C) or maximum operating pressure exceeding 275 psig(19.3kg/cm{sup 2}) during normal operating conditions in nuclear power plants. A high energy pipe failure is postulated in branches or piping that runs larger than one inch nominal diameter. The resultant consequences of these postulated pipe breaks must be analyzed for the effect on maintenance of plant safe shutdown capability, containment integrity. And the analyzed results must be applied to the system design so that a pipe failure can not damage essential systems to an extent of impairing design function nor affect necessary component operability. The considerable effects of pipe break are as follows; dynamic effects such as pipe whip, jet impingement and environmental impact by release of system contents. Two types of forces are occurred by the pipe whip. The one is pipe whip impact force that ...

2007-10-15

238

Ultra fine grinding of low-rank coal. Progress report, April-June 1986  

Energy Technology Data Exchange (ETDEWEB)

The lignite used for Phase I of the project was a Texas lignite from the Martin Lake mine obtained from the stockpile for the Martin Lake Power Plant of the Texas Utilities Generating Company. The power requirements for the fluid-energy mill were determined from the measured steam (or air) temperatures, pressures and pressure drops and the lignite flow rate. The instrument locations for the tests are shown on Figure 1. All of the instruments were connected to a microcomputer via an analog input interface board. Data were recorded on disks periodically throughout the tests. Appropriate calibration procedures were followed to assure that reliable data were being obtained. The combined grinding/drying tests were conducted in Vicksbuth, MS at Ergon, Inc.'s fluid-energy-mill facility. both steam and air were used as grinding fluids. With steam, tests were used as grinding fluids. With steam, tests ...

1986-07-01

239

The composition-explicit distillation curve technique: Relating chemical analysis and physical properties of complex fluids.  

Science.gov (United States)

The analysis of complex fluids such as crude oils, fuels, vegetable oils and mixed waste streams poses significant challenges arising primarily from the multiplicity of components, the different properties of the components (polarity, polarizability, etc.) and matrix properties. We have recently introduced an analytical strategy that simplifies many of these analyses, and provides the added potential of linking compositional information with physical property information. This aspect can be used to facilitate equation of state development for the complex fluids. In addition to chemical characterization, the approach provides the ability to calculate thermodynamic properties for such complex heterogeneous streams. The technique is based on the advanced distillation curve (ADC) metrology, which separates a complex fluid by distillation into fractions that are sampled, and for which thermodynamically consistent temperatures ...

2009-11-17

240

Numerical study on the heat transfer to CO_2 flowing upward in a heated vertical tube at supercritical pressure  

International Nuclear Information System (INIS)

Full text of publication follows: As the coolant experiences no phase change in the core, SCWRs, unlike LWRs, cannot use design criteria based on the critical heat flux concept. The commonly accepted practice in SCWRs is to specify cladding temperature limits that must be met during transient and accident events. Therefore for the design of the SCWR, it is very important to predict the heat transfer coefficient to the supercritical water coolant with great accuracy. Our recent study focuses on the critical issue of measuring heat transfer to supercritical water at prototypical SCWR conditions and to develop the tools to predict the SCWR thermal behavior. A heat transfer test loop using a surrogate fluids, CO_2, is under construction. The reason of using CO_2 instead of water is that (i) valuable insight of the physical phenomena can be obtained with this fluid, and (ii) some existing facilities already used surrogate ...

2005-10-02

241

A nonmolecular derivation of Maxwell's thermal-creep boundary condition in gases and liquids via application of the LeChatelier-Braun principle to Maxwell's thermal stress  

Science.gov (United States)

According to the LeChatelier-Braun principle, when a closed quiescent system initially in an equilibrium or unstressed steady state is subjected to an externally imposed ``stress'' it responds in a manner tending to alleviate that stress. Use of this entropically based qualitative rule, in combination with the notion of Maxwell thermal stresses existing in nonisothermal gases and liquids, enables one to (i) derive Maxwell's thermal-creep boundary condition prevailing at the boundary between a solid and a fluid (either gas or liquid) and (ii) rationalize the phenomenon of thermophoresis in liquids, for which, in contrast with the case of gases, an elementary explanation is currently lacking. These two objectives are achieved by quantitatively interpreting the heretofore qualitative LeChatelier-Braun notion of stress in the present context as being the fluid's stress tensor, the latter including Maxwell's thermal stress. In effect, thermophoretic ...

2009-05-01

242

Wireline well logging an underutilized technique in reservoir evaluation  

Energy Technology Data Exchange (ETDEWEB)

Wireline well logs have three general uses in geothermal exploration and reservoir evaluation: reservoir parameter analysis, lithologic column determination, and reservoir size resolution. Reservoir flow testing data are acquired to understand the flow rate, life, and production potential of the geothermal reservoir. These data are a coarse subsurface measurement of the geothermal prospect. Wireline logs acquired from wells in a geothermal prospect are used to define in detail, or estimate the reservoir parameters of temperature, thickness, lateral size, amount of fracture and intergranular pore space, and the quantity and quality of fluid that might be produced. Laboratory measurements can be made on core samples and drill cuttings samples to define the intrinsic behavior of the materials and fluid that compose the geotheraml reservoir. Wireline log measurements are needed to correlate and link the reservoir testing and core analysis, reduce ...

1981-01-01

243

Vibration test report on the instrumented capsule for fuel irradiation test  

Energy Technology Data Exchange (ETDEWEB)

The fluid-induced vibration level of instrumented capsule, which was manufactured for fuel irradiation test at the reactor core of HANARO, was investigated. For this purpose, the instrumented capsule was loaded at the OR site of the HANARO design verification test facility that could simulate identical flow condition as the HANARO core. Then, vibration signals of the instrumented capsule subjected to various flow conditions were measured by using vibration sensors. In time domain analysis, maximum amplitudes and RMS values of the measured acceleration and displacement signals were obtained. By using frequency domain analysis, frequency components of the fluid-induced vibration were analyzed. In addition, natural frequencies of the instrumented capsule were obtained by performing modal test. The frequency analysis results showed that the natural frequency components near 7.5Hz and 17.5Hz were dominant in the fluid-induced ...

2003-01-01

244

Two-fluid modeling of condensation in the presence of noncondensables in two-phase channel flows  

Energy Technology Data Exchange (ETDEWEB)

Condensing two-phase channel flow occurs in many industrial applications, including heating and refrigeration systems. It can also occur in certain nuclear reactor accidents. For example, during a small-break loss-of-coolant accident in a pressurized water reactor, following the partial depletion of the primary coolant, condensation of steam on the primary side of the steam generator tubes can provide a heat sink for disposal of the decay heat generated in the reactor core. Condensing two-phase flow can also play an important role in the operation of the passive emergency cooling system in the advanced simplified boiling water reactor. Here, steady-state condensation in the presence of a noncondensable in a concurrent two-phase channel flow is analyzed using a two-fluid model. The effect of noncondensables on the combined heat transfer at the liquid-gas mixture interphase is accounted for by using the stagnant film model, and closure relations relevant to the ...

1995-01-01

245

Three-dimensional multispecies current density simulation of molten-salt electrorefining  

Energy Technology Data Exchange (ETDEWEB)

This study presents three-dimensional simulation results of multispecies and multi-reaction electrorefining for spent nuclear waste treatment. Fluid-dynamic behavior of electrorefining is analyzed by commercial computational fluid-dynamics code. The results of local fluid dynamics are coupled with one-dimensional electrochemical reaction analysis code in order to predict local current density distribution. The new approach shows current distribution patterns over the cathode surface in LiCl-KCl molten-salt electrolyte. The current density distribution patterns are analyzed for various electrode rotational speeds and diverse applied currents and the results show a good agreement with general principle of mass transfer observations. Spatially periodic and vertically striped pattern of current density is predicted at the cathode side due to mass transfer depression at separation points. These slow mass transfer regions are ...

2010-07-30

246

TheU-Tube: A Novel System for Acquiring Borehole Fluid Samplesfrom a Deep Geologic CO2 Sequestration Experiment  

Energy Technology Data Exchange (ETDEWEB)

A novel system has been deployed to obtain geochemical samples of water and gas, at in situ pressure, during a geologic CO2 sequestration experiment conducted in the Frio brine aquifer in Liberty County, Texas. Project goals required high-frequency recovery of representative and uncontaminated aliquots of a rapidly changing two-phase (supercritical CO2-brine) fluid from 1.5 km depth. The datasets collected, using both the liquid and gas portions of the downhole samples, provide insights into the coupled hydro-geochemical issues affecting CO2 sequestration in brine-filled formations. While the basic premise underlying the U-Tube sampler is not new, the system is unique because careful consideration was given to the processing of the recovered two-phase fluids. In particular, strain gauges mounted beneath the high-pressure surface sample cylinders measured the ratio of recovered brine to supercritical CO2. A quadrupole mass spectrometer provided ...

2005-03-17

247

Study of structural, thermodynamical and dynamical properties of molecular liquids confined in nano-porous materials  

International Nuclear Information System (INIS)

When liquids are confined in nano-scopic dimensions, their properties differ from the corresponding bulk liquid, due to their reduced dimensionality and surface effects. Phase transition temperatures and pressures are often shifted from the bulk values and new phases can appear due to the strong interactions of the molecules with the confining walls. We have studied the structural and dynamical properties of aromatic liquids such as benzene, toluene, and ortho-terphenyl confined in nano-porous materials, MCM-41 and SBA-15, synthesized and characterized in our laboratory. A non-trivial dependence of the glass transition temperature, Tg, on the pore size and surface treatment of nano-porous materials is confirmed and interpreted as resulting from a competition between the fluid-wall and fluid-fluid intermolecular interactions. An increase of Tg is observed for small pore sizes and attractive surface while Tg decreases for non attractive surface, ...

2006-01-01

248

Release of zinc from disposable coils during hemodialysis  

Energy Technology Data Exchange (ETDEWEB)

In a prior study, we demonstrated that certain disposable coils are contaminated with zinc and release substantial quantities of Zn during hemodialysis, producing high post-dialysis plasma Zn concentrations. The present investigation was designed to monitor plasma and dialysis fluid Zn and copper throughout dialysis and to estimate patient Zn and Cu uptake. Venous plasma, arterial plasma and coil chamber fluid were sampled periodically throughout dialysis; trace metal concentrations were determined by flame atomic absorption spectrophotometry. Release of considerable quantities of Zn from the coils into the dialysis fluid, with uptake into the patient's plasma, was found. Approximately one-half of the plasma Zn uptake occurred in the first 45 minutes. Coils from different lots released significantly different quantities of Zn. Patient uptake of Zn ranged from 3.2 mg-23.0 mg, with a mean of 15.0 +- 6.1 mg. Copper ...

1981-06-01

249

Power-cycle studies for a geothermal electric plant for MX operating bases  

Energy Technology Data Exchange (ETDEWEB)

Binary geothermal plants were investigated for providing electrical power for MX missile bases. A number of pure hydrocarbons and hydrocarbon mixtures were evaluated as working fluids for geothermal resource temperatures of 365, 400, and 450/sup 0/F. Cycle thermodynamic analyses were conducted for pure geothermal plants and for two types of coal-geothermal hybrid plants. Cycle performance results were presented as net geofluid effectiveness (net plant output in watts per geofluid flow in 1 bm/hr) and cooling water makeup effectiveness (net plant output in watts per makeup water flow in 1 bm/hr). A working fluid containing 90% (mass) isobutane/10% hexane was selected, and plant statepoints and energy balances were determined for 20MW(e) geothermal plants at each of the three resource temperatures. Working fluid heaters and condensers were sized for these plants. It is concluded that for the advanced plants investigated, ...

1981-11-01

250

Nonlinear dynamics of a flexible rotor supported by turbulent journal bearings with couple stress fluid  

Energy Technology Data Exchange (ETDEWEB)

This study presents a dynamic analysis of a rotor supported by two turbulent flow model journal bearings and lubricated with couple stress fluid under nonlinear suspension. The dynamics of the rotor center and bearing center is studied. The dynamic equations are solved using the Runge-Kutta method. The analysis methods employed in this study is inclusive of the dynamic trajectories of the rotor center and bearing center, power spectra, Poincare maps and bifurcation diagrams. The maximum Lyapunov exponent analysis is also used to identify the onset of chaotic motion. The results show that the values of dimensionless parameters l* strongly influence dynamic motions of bearing and rotor centre. It is found that couple stress fluid improve the stability of the system when l* > 0.4 even if the flow of this system is turbulent. We also demonstrated that the dimensionless rotational speed ratios s and the dimensionless unbalance parameter ...

2008-08-15

251

Nonlinear dynamics of a flexible rotor supported by turbulent journal bearings with couple stress fluid  

International Nuclear Information System (INIS)

This study presents a dynamic analysis of a rotor supported by two turbulent flow model journal bearings and lubricated with couple stress fluid under nonlinear suspension. The dynamics of the rotor center and bearing center is studied. The dynamic equations are solved using the Runge-Kutta method. The analysis methods employed in this study is inclusive of the dynamic trajectories of the rotor center and bearing center, power spectra, Poincare maps and bifurcation diagrams. The maximum Lyapunov exponent analysis is also used to identify the onset of chaotic motion. The results show that the values of dimensionless parameters l* strongly influence dynamic motions of bearing and rotor centre. It is found that couple stress fluid improve the stability of the system when l* > 0.4 even if the flow of this system is turbulent. We also demonstrated that the dimensionless rotational speed ratios s and the dimensionless unbalance parameter #beta# ...

2008-08-01

252

Matter and dynamics in closed cosmologies  

International Nuclear Information System (INIS)

To systematically analyze the dynamical implications of the matter content in cosmology, we generalize earlier dynamical systems approaches so that perfect fluids with a general barotropic equation of state can be treated. We focus on locally rotationally symmetric Bianchi type IX and Kantowski-Sachs orthogonal perfect fluid models, since such models exhibit a particularly rich dynamical structure and also illustrate typical features of more general cases. For these models, we recast Einstein's field equations into a regular system on a compact state space, which is the basis for our analysis. We prove that models expand from a singularity and recollapse to a singularity when the perfect fluid satisfies the strong energy condition. When the matter source admits Einstein's static model, we present a comprehensive dynamical description, which includes the qualitative asymptotic behavior, of models in the neighborhood of the ...

2005-04-15

253

Investigation and improvement of ejector refrigeration system using computational fluid dynamics technique  

Energy Technology Data Exchange (ETDEWEB)

Ejector refrigeration systems are usually designed to utilize low grade energy for driving the cycle. They also have low maintenance cost because they operate without a compressor. Mainly, the ejector performance directly affects the refrigerating performance. Therefore, an investigation on the characteristics and an efficient design of the ejector are important to improve ejector refrigeration systems. In this study, the computational fluid dynamics (CFD) code, FLUENT, is employed to predict the flow phenomena and performance of CPM and CMA steam ejectors. The ejector refrigeration system, using water as the working fluid, is operated at 120-140 C boiler temperature and 5-15 C evaporator temperature. CFD can predict ejector performance very well and reveal the effect of operating conditions on an effective area that is directly related to its performance. Besides, it is found that the flow pattern does not depend much on the suction zone ...

2007-09-15

254

Feasibility of an antiproton catalyzed fission fragment rocket  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this project was to investigate the feasibility of an antiproton catalyzed fission fragment rocket (FFR). The FFR is characterized by the extraction of fission fragments from the fissile fuel, and the utilization of their kinetic energy for thrust generation. A significant drawback to previous FFR designs was the requirement to maintain a critical nuclear pile as the fission fragment source. The author examined the possibility of replacing the critical pile with a sub-critical pile driven by antiprotons. Recent experiments have revealed that antiprotons stimulate highly energetic fissions in {sup 238}U, with a neutron multiplicity of 13.7 neutrons per fission. This interaction was used as a throttled neutron source. The pile consisted of layers of fissile coated fibers which are designed to allow fission fragments to escape them, where the fragments collide with a fluid. The heated fluid is then ejected from the rocket to provide ...

1992-03-01

255

Evaluation of advanced technologies for power transformers. Final report  

Energy Technology Data Exchange (ETDEWEB)

The high insulating strength of certain gases, such as sulfur hexafluoride, when used at high pressure, suggests that there may be advantages to compressed gases as the insulating fluid in power transformers. However, simply exchanging the oil for compressed gas in an otherwise conventional transformer design will not yield a significant overall advantage. Compressed gases present the engineer with properties which are quite different from mineral oil. If gases are to be used as the major insulating fluid in power transformers, then virtually all aspects of the insulation and cooling of the apparatus must be reconsidered, affording an opportunity to introduce new design concepts, new materials, and new construction techniques. In this program, the feasibility of using the following principal design concepts has been explored: sheet conductors for the windings; a system of sealed, self-contained, annular cooling ducts containing circulating ...

1981-01-01

256

Diverter/bop system and method for a bottom supported offshore drilling rig  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a system adapted for alternative use as a diverter or a blowout preventer for a bottom supported drilling rig and adapted for positioning beneath a rotary table of the drilling rig, the system comprising: a fluid flow controller having a controller housing with a lower opening and an upper opening and a vertical flow path therebetween and an outlet passage provided in its housing wall, and at least two bases. A method is described for installing a system adapted for alternative connection as a diverter or a blowout preventer for a bottom supported drilling rig positioned beneath a rotary table of the drilling rig after structural casing has been set in a borehole. The method comprises: positioning a first telescoping spool having a lower end and an upper end below the rotary table, the first spool having a first base disposed at its upper end, the first base having a port disposed in its wall; aligning a fluid flow ...

1987-03-03

257

Diverter bop system and method for a bottom supported offshore drilling rig  

Energy Technology Data Exchange (ETDEWEB)

A system and method for installing a fluid flow controller and telescoping spools beneath an offshore bottom supported drilling rig rotary table is disclosed. Upper and lower telescoping spools are provided for initially connecting a Diverter/BOP convertible fluid flow controller between structural casing in the well and a permanent housing beneath the drilling rig rotary table. Clamp means are provided for clamping the rig vent line to an opening in the housing wall of the fluid flow controller during drilling of the borehole through the structural casing in preparation for setting and cementing the conductor casing. In that mode, the system is adapted as a diverter system. After the well is drilled for the conductor casing and the conductor casing is cemented and cut off at its top, a mandrel is fitted at the top of the conductor casing to which the lower end of the lower spool may be connected. The system may be used in ...

1985-06-25

258

Corrosion in drilling and well stimulation  

Energy Technology Data Exchange (ETDEWEB)

Corrosion in drilling and well stimulation is described in relation to acid corrosion inhibition, acid inhibitors, acetylenic inhibitors, synergistic blends, metallurgy, wellbore tubulars, coiled tubing, and high alloy tubular materials. Acidizing is a procedure for stimulating oil and gas wells. Factors that have an important influence on the reaction rate and the way in which acid reacts with rock include temperature, acid concentration, acid volume, injection velocity, acid viscosity, and fluid loss properties of the formation. The cost of drill pipe failures are $1 per fot of hole drilled, which is a significant fraction of the drilling cost. Steps in a test procedure are listed, as well as factors which determine the extent of acid corrosion in a given situation including acid type and strength, metal type, temperature, contact time; pressure, and volume/surface area ratio. Underbalanced drilling is a method for completing oil and gas wells that minimizes the ...

1999-07-01

259

Conceptual fusion power monitor based on the "1"6O(n,p)"1"6N reaction  

International Nuclear Information System (INIS)

The feasibility of developing a fusion power monitor based on a fluid activation detector is considered here. The activation fluid may be either a liquid or a gas and its composition can be selected from a number of candidate materials to provide desired activation and decay characterisitcs. Performance calculations indicate that ordinary water would be a nearly ideal activation fluid. The "1"6O(n,p)"1"6N reaction has a threshold at about 10 MeV and a cross section energy dependence giving it a predominant response for unmoderated D-T fusion neutrons. Adequate activation can be obtained at moderate flow rates for remote counting away from the high radiation area of the reactor. The 7.16 sec half-life of "1"6N is ideal for remote counting with subsequent decay in a small hold-up tank to eliminate activity build-up in the recycled water.

1981-07-01

260

Chaos and bifurcation of a flexible rotor supported by porous squeeze couple stress fluid film journal bearings with non-linear suspension  

Energy Technology Data Exchange (ETDEWEB)

This study presents a dynamic analysis of a flexible rotor supported by two porous squeeze couple stress fluid film journal bearings with non-linear suspension. The dynamics of the rotor center and bearing center are studied. The analysis of the rotor-bearing system is investigated under the assumptions of non-Newtonian fluid and a short bearing approximation. The spatial displacements in the horizontal and vertical directions are considered for various non-dimensional speed ratios. The dynamic equations are solved using the Runge-Kutta method. The analysis methods employed in this study is inclusive of the dynamic trajectories of the rotor center and bearing center, power spectra, Poincare maps and bifurcation diagrams. The maximum Lyapunov exponent analysis is also used to identify the onset of chaotic motion. The numerical results show that the stability of the system varies with the non-dimensional speed ratios, the non-dimensional ...

2008-01-15

261

Chaos and bifurcation of a flexible rotor supported by porous squeeze couple stress fluid film journal bearings with non-linear suspension  

International Nuclear Information System (INIS)

This study presents a dynamic analysis of a flexible rotor supported by two porous squeeze couple stress fluid film journal bearings with non-linear suspension. The dynamics of the rotor center and bearing center are studied. The analysis of the rotor-bearing system is investigated under the assumptions of non-Newtonian fluid and a short bearing approximation. The spatial displacements in the horizontal and vertical directions are considered for various non-dimensional speed ratios. The dynamic equations are solved using the Runge-Kutta method. The analysis methods employed in this study is inclusive of the dynamic trajectories of the rotor center and bearing center, power spectra, Poincare maps and bifurcation diagrams. The maximum Lyapunov exponent analysis is also used to identify the onset of chaotic motion. The numerical results show that the stability of the system varies with the non-dimensional speed ratios, the non-dimensional ...

2008-01-01

262

CFD simulation of flow distribution in the header of plate-fin heat exchangers  

Energy Technology Data Exchange (ETDEWEB)

The flow distribution through a plate-fin heat exchanger is studied by using a computational fluid dynamics (CFD) code, FLUENT. The flow distribution through any heat exchanger affects its performance. In designing a heat exchanger, it is assumed that the fluid is uniformly distributed through the heat exchanger core. In practice, however, it is impossible to distribute fluid uniformly, because of an improper inlet configuration, imperfect design, and a complex heat transfer process. The CFD simulation of the flow distribution in the header of a conventional plate-fin heat exchanger is presented. It is found that the flow maldistribution is very serious in the y-direction of the header. A modified header is proposed and simulated using CFD. The modified header configuration has a more uniform flow distribution than the conventional header configuration. Hence, the efficiency of the modified heat exchanger is seen to be ...

2007-10-15

263

Augmentation of heat transfer in heat conductive medium by electro-hydrodynamic effect  

Energy Technology Data Exchange (ETDEWEB)

A method of augmenting heat transfer in the interior of a fluid or from the interface of a solid in contact to a fluid by utilizing electro hydrodynamic (EHD) phenomena has the following advantages: the heat transfer can be effected by using a relatively small, light-weight high voltage source and some simple structural members; no vibration and noise are generated; the method has a control function to control heat transfer by adjustment of field and voltage; and this method is effective in cost-saving. It is mass transfer by the electric force caused by interaction between true charges or polarized charges in a fluid and external electric filed that plays an important role in most of such heat transfer augmentation methods by EHD. Examples of heat transfer augmentation by EHD phenomena include electricaly induced convection, contribution of EHD effect to heat transfer accompanied with boiling, heat transfer by corona wind ...

1988-04-20

264

Analysis of flow-induced vibration by improvement of design in UCN 5,6 steam generator  

Energy Technology Data Exchange (ETDEWEB)

Youngkwang Unit 3,4 and Ulchin Unit 3 and 4 have had problem of the KSNP Steam Generator due to a severe fretting wear on the tube. In particular, the wears were localized and concentrated in the upper part of U-bend of the Central Cavity region. At the upper tube bundle Central Cavity, the fluid flow velocities and void fraction are very high, because the steam is made by high heat transfer at secondary region. Also, this region is affected easily by fretting wear due to it's unsupported span is longer than another regions. The fretting wear is assumed to be result of Flow-Induced Vibration (F. I. V), which can occur by many mechanisms. EFDP was added to UCN 5,6 for prevent fretting wear by the SEC LCC and DSHIC, a company of design and manufacture of the steam generator, respectively. In order to evaluate the efficacy of EFDP, ANSYS and ATHOS-3 Code were used. From sensitivity analysis and calculation results, Density and Velocity into the Central Cavity ...

2001-10-01

265

Analysis of flow-induced vibration by improvement of design in UCN 5,6 steam generator  

International Nuclear Information System (INIS)

Youngkwang Unit 3,4 and Ulchin Unit 3 and 4 have had problem of the KSNP Steam Generator due to a severe fretting wear on the tube. In particular, the wears were localized and concentrated in the upper part of U-bend of the Central Cavity region. At the upper tube bundle Central Cavity, the fluid flow velocities and void fraction are very high, because the steam is made by high heat transfer at secondary region. Also, this region is affected easily by fretting wear due to it's unsupported span is longer than another regions. The fretting wear is assumed to be result of Flow-Induced Vibration (F. I. V), which can occur by many mechanisms. EFDP was added to UCN 5,6 for prevent fretting wear by the SEC LCC and DSHIC, a company of design and manufacture of the steam generator, respectively. In order to evaluate the efficacy of EFDP, ANSYS and ATHOS-3 Code were used. From sensitivity analysis and calculation results, Density and Velocity into the Central Cavity are ...

2001-10-01

266

Well Test Analysis in Naturally Fissured, Geothermal Reservoirs with Fracture Skin  

Science.gov (United States)

Mineral deposition or alteration is commonly found at fracture-block interfaces is fissured, geothermal reservoirs. In response to pressure reduction in the fissures such mineralization, if less permeable than the matrix rock, will retard the flow of fluid from the blocks to the fissures and is termed fracture skin in this paper. The problem of fluid flow to a production well in a double-porosity reservoir with fracture skin was analyzed theoretically. One of the findings of the analysis was that fully transient block-to-fissure flow can be approximated by pseudo-steady state flow if fracture skin permeability is sufficiently low. Type curves generated by numerical inversion of Laplace transform solutions are used to cooroborate the results of a finite-difference model of steam transport to a well in a naturally fissured, geothermal reservoir with fracture skin.

1983-12-15

267

Variable structure system based logic fuzzy control of bridge vibration using fail-safe magnetorheological fluid dampers  

Science.gov (United States)

This paper presents a semi-active vibration control of a scaled two-span bridge structure. Magneto-rheological fluid dampers are utilized as the semi-active energy absorbing deices and a bridge vibration control system is developed. Closed-loop control system based on fuzzy logic is used to suppress the bridge deck motion under random excitations. The sufficient condition for the closed-loop stability of the fuzzy control system is derived from the variable structure system theory. It is demonstrated that this stable fuzzy control system can significantly reduce the relative deck displacement using about 55 percent less power compared to passive-on state, while the absolute deck acceleration is relatively unaffected.

2002-06-01

268

Transient Fluid Dynamics of the Quark-Gluon Plasma According to AdS/CFT  

CERN Document Server

We prove, using the AdS/CFT correspondence, that the long wavelength dynamics of the shear stress tensor in a strongly coupled N=4 SYM plasma is not described by the relaxation-type, fluid dynamical equations proposed by Israel and Stewart: the coarse grained dynamics will necessarily contain a second-order comoving derivative of the shear stress tensor. We argue that this should be true for any strongly-coupled gauge theory with a gravity dual. If the QGP formed in heavy ion collisions can indeed be described in terms of a (yet unknown) theory of gravity in higher dimensions, the equations of motion used in hydrodynamical simulations of the QGP must necessarily include second order comoving derivatives of the shear stress tensor.

2011-01-01

269

Thermal diffusion by Brownian motion induced fluid stress  

CERN Document Server

The Ludwig-Soret effect, the migration of a species due to a temperature gradient, has been extensively studied without a complete picture of its cause emerging. Here we investigate the dynamics of DNA and spherical particles sub jected to a thermal gradient using a combination of Brownian dynamics and the lattice Boltzmann method. We observe that the DNA molecules will migrate to colder regions of the channel, an observation also made in the experiments of Duhr, et al[1]. In fact, the thermal diffusion coefficient found agrees quantitatively with the experimental value. We also observe that the thermal diffusion coefficient decreases as the radius of the studied spherical particles increases. Furthermore, we observe that the thermal fluctuations-fluid momentum flux coupling induces a gradient in the stress which leads to thermal migration in both systems.

2007-01-01

270

The questions of liquid metal two-phase flow modelling in the FBR core channels  

International Nuclear Information System (INIS)

The two-fluid model representation for calculations of two-phase flow characteristics in the FBR fuel pin bundles with liquid metal cooling is presented and analysed. Two conservation equations systems of the mass, momentum and energy have been written for each phase. Components accounted the mass-, momentum- and heat transfer throughout the interface occur in the macro-field equations after the averaging procedure realisation. The pattern map and correlations for two-fluid model in vertical liquid metal flows are presented. The description of processes interphase mass- and heat exchange and interphase friction is determined by the two-phase flow regime. The opportunity of the liquid metal two-phase flow regime definition is analysed. (author)

2000-06-01

271

The influence of wall deposits on heat transfer in combustion engines. Einfluss von Wandablagerungen auf den Waermeuebergang im Verbrennungsmotor  

Energy Technology Data Exchange (ETDEWEB)

The experimental survey about the heat transfer between the working fluid and the combustion chamber wall with a direct injection diesel engine has shown the production of a soot layer with increasing loads on the combustion chamber wall. Because the combustion process of methanol occurs without the formation of wall deposits, the same engine spark ignitioned with methanol at the same conditions has shown a higher heat transfer coefficient. Because the heat losses do not only depend on the heat transfer coefficient but also on the driving temperature difference between the working fluid and the combustion chamber wall, the methanol engine with corresponding process management showed lower heat losses than the diesel engine at nearly the same load. (orig./HW)

1994-04-01

272

The effects of radiation on unsteady mhd convective heat transfer past a semi-infinite vertical porous moving surface with variable suction  

Scientific Electronic Library Online (English)

Abstract in english Numerical solutions for the effects of radiation on a MHD convective heat transfer past a semi-infinite porous plate with a magnetic field are obtained. It is assumed that the porous plate moves with a constant velocity in the direction of fluid flow, and the free stream velocity follows the exponentially increasing small perturbation law. The magnetic field acts perpendicular to the porous surface which absorbs the fluid with a suction velocity varying with time. The gov (more) erning equations for the flow are transformed into a system of nonlinear ordinary differential equations by perturbation technique and then are solved numerically by using the shooting method. The effects of the various parameters on the velocity, temperature profiles as well as the surface skin-friction and surface heat transfer are illustrated graphically.

2008-12-01

273

The Onset of Double Diffusive Convection in a Couple Stress Fluid Saturated Anisotropic Porous Layer  

British Library Electronic Table of Contents (United Kingdom)

The double diffusive convection in a horizontal couple stress fluid saturated anisotropic porous layer, which is heated and salted from below, is studied analytically. The modified Darcy equation that includes the time derivative term is used to model the momentum equation. The critical Rayleigh number, wavenumber for stationary and oscillatory modes, and frequency of oscillations are obtained analytically using linear theory. The effect of anisotropy parameter, solute Rayleigh number, Lewis number, couple stress parameter, and Vadasz number on the stationary, oscillatory, and finite amplitude convection is shown graphically. It is found that the thermal anisotropy parameter, couple stress parameter, and solute Rayleigh number have stabilizing effect on the stationary, oscillatory, and fin...

2011-01-01

274

Supercritical Fluid Immersion Deposition: A New Process for Selective Deposition of Metal Films on Silicon Substrates  

Energy Technology Data Exchange (ETDEWEB)

Supercritical CO2 is used as a new solvent for immersion deposition, a galvanic displacement process traditionally carried out in aqueous HF solutions containing metal ions, to selectively develop metal films on featured or non-featured silicon substrates. Components of supercritical fluid immersion deposition (SFID) solutions for fabricating Cu and Pd films on silicon substrates are described along with the corresponding experimental setup and procedure. Only silicon substrates exposed and reactive to SFID solutions can be coated. The highly pressurized and gas-like supercritical CO2, combined with the galvanic displacement property of immersion deposition, enables the SFID technique to selectively deposit metal films in small features. SFID may also provide a new method to fabricate palladium silicide in small features or to metallize porous silicon.

2005-01-01

275

Sterically stabilized water based magnetic fluids: Synthesis, structure and properties  

Energy Technology Data Exchange (ETDEWEB)

Magnetic fluids (MFs), prepared by chemical co-precipitation followed by double layer steric and electrostatic (combined) stabilization of magnetite nanoparticles dispersed in water, are presented. Several combinations of surfactants with different chain lengths (lauric acid (LA), myristic acid (MA), oleic acid (OA) and dodecyl-benzene-sulphonic acid (DBS)) were used, such as LA+LA, MA+MA, LA+DBS, MA+DBS, OA+DBS, OA+OA and DBS+DBS. Static light scattering, transmission electron microscopy, small angle neutron scattering, magnetic and magneto-rheological measurements revealed that MFs with MA+MA or LA+LA biocompatible double layer covered magnetite nanoparticles are the most stable colloidal systems among the investigated samples, and thus suitable for biomedical applications.

2007-04-15

276

Some anisotropic universes in the presence of imperfect fluid coupling with spatial curvature  

CERN Document Server

We consider Bianchi VI spacetime, which also can be reduced to Bianchi types VI0-V-III-I. We initially consider the most general form of the energy-momentum tensor which yields anisotropic stress and heat flow. We then derive an energy-momentum tensor that couples with the spatial curvature in a way so as to cancel out the terms that arise due to the spatial curvature in the evolution equations of the Einstein field equations. We obtain exact solutions for the universes expanding with constant deceleration parameter. The solutions are reduced to each Bianchi type. The dynamics of the models and fluid are examined briefly, and the models that can approach to isotropy are determined.

2010-01-01

277

Simulation of the filtration mechanism of hyaluronic acid in total knee prosthesis  

Energy Technology Data Exchange (ETDEWEB)

Polyethylene (UHMWPE) wear in current knee prosthesis causes prosthesis loosening after no more than 15 years. In this work, a steady state one-dimensional lubrication model with non- Newtonian fluid, porous elastic layer on tibial component, ultra-filtration mechanism of fluid and some features of the surface roughness is studied through a numerical technique based on the Finite Element Method. The results show that the UHMWPE stiffness makes difficult the lubrication mechanism of the artificial joint and promotes abrasive and fatigue wear. Nevertheless, the use of compliant porous materials on the tibial component could reduce friction and wear. Moreover, the ultra-filtration mechanism promotes efficiency on the joint.

2007-11-15

278

Semiactive field-controllable magneto-rheological fluid dampers for mountain bicycles  

Science.gov (United States)

This paper presents the development and evaluation of field- controllable, semi-active magneto-rheological fluid (MRF) shock absorbers for a mountain bicycle. Recent trends in the bicycle industry show a movement towards semi-active suspension systems. Two new MRF dampers are designed and tested with the intent of being used on the front and rear suspension of a modern mountain bicycle. The MRF shock absorbers are designed to emulate the performance of the original equipment manufacturer shock absorbers in passive mode. Application of an input electric current to the MRF shock absorber causes a dramatic increase in the damping capacity. Procedures and results are presented for the design and experimental characterization of these MRF dampers.

2000-06-01

279

Real-time neutron radiography applications in dynamic fluid flow studies  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography (RTNR) is now proving to be a valuable research tool in the study of hydrogenous fluid flow. One of the most significant advantages of neutron radiography is the ability to image hydrogenous substances (such as lubricants, coolants, and fuels) inside metallic materials such as aluminum and titanium engines. By using RTNR, one can then study dynamic events such as the movement of liquids inside these solids. The Phoenix Memorial Laboratory (PML) at the University of Michigan has recently developed and installed a facility dedicated to RTNR. The work at PML has shown that RTNR of dynamic events can provide information enabling the researcher to follow dynamic events that were previously impossible or impractical. This paper will show the variety of uses of RTNR presently being pursued at PML.

1986-01-01

280

Real-time neutron radiography applications in dynamic fluid flow studies  

International Nuclear Information System (INIS)

Real-time neutron radiography (RTNR) is now proving to be a valuable research tool in the study of hydrogenous fluid flow. One of the most significant advantages of neutron radiography is the ability to image hydrogenous substances (such as lubricants, coolants, and fuels) inside metallic materials such as aluminum and titanium engines. By using RTNR, one can then study dynamic events such as the movement of liquids inside these solids. The Phoenix Memorial Laboratory (PML) at the University of Michigan has recently developed and installed a facility dedicated to RTNR. The work at PML has shown that RTNR of dynamic events can provide information enabling the researcher to follow dynamic events that were previously impossible or impractical. This paper will show the variety of uses of RTNR presently being pursued at PML.

1986-11-16

281

Radon as a tracer of fluids motion in karstic aquifers; Le radon: traceur des circulations fluides dans les aquiferes karstiques  

Energy Technology Data Exchange (ETDEWEB)

Radon ({sup 222}Rn) is a naturally occurring radioactive gas and can be used as a tracer in hydrogeologic studies. Radon concentration measurements have been achieved in ground-air and in groundwater by means of nuclear track detectors to estimate long-term variations. Continuous measurements have been conducted using an electronic automatic probe, to evaluate short-term variations. The results obtained from bore-holes show a good correlation between the aquifer`s structural characteristics and the radon concentrations. The continuous measurements specify rainfall influence. (author). 10 refs., 7 figs., 2 tabs.

1995-04-01

282

Proposal for a commercial interconnection among the Hawaiian islands based on the results of the Hawaii deep water cable program  

Energy Technology Data Exchange (ETDEWEB)

After the successful completion of the development program of the 2000 m water depth HVDC Hawaii Deep Water Self Contained Fluid Filled Cable, the interconnection between Hawaii island and Oahu island is examined. Thermal, electrical, mechanical, hydraulic, corrosion, length aspects are developed for both fluid filled and paper impregnated (SOLID) cables which are foreseen in different portions of the approximately 250 km length connection. Considerations are also presented for the requirements of the cable ship: 12 m sheave diameter, 7000 t capacity for the rotating platform. The feasibility of manufacturing, transporting and laying such cables within a practical schedule is discussed in this paper.

1992-10-01

283

Post-CHF heat transfer with water and refrigerants  

Energy Technology Data Exchange (ETDEWEB)

Heat transfer experiments were performed in the post-CHF two-phase flow regime in a vertical tube. The tube inside diameter was 7.75 mm, and the boiling fluid was R-113. The experiments were performed at steady state by means of liquid heating of the test tube. Wall superheats were maintained below 70 C for heat exchanger/steam generator application. The mass flux range of the data was 379-816 kg m{sup -2} s{sup -1}. The use of R-113 significantly extended the property range of the existing low wall-superheat data base. Experimental data are presented in tabular as well as graphical form, and the results were used with low wall-superheat data from other fluids to add generality to a predictive heat transfer correlation. (orig.)

1996-06-01

284

Phylogenetic constraints on digesta separation: Variation in fluid throughput in the digestive tract in mammalian herbivores  

British Library Electronic Table of Contents (United Kingdom)

The relevance of the mean retention time (MRT) of particles through the gastrointestinal tract (GIT) is well understood and MRTparticleGIT is an important parameter in digestion models. Solute markers have been used to estimate MRTsoluteGIT (or 'fluid passage') in animals, but the relevance of this measure is less evident and is usually sought in its relation to MRTparticleGIT. The ratio between the two measures indicates the degree of 'digesta washing', with little washing occurring at ratios of 1, aborad washing at ratios >1 (where the solute marker travels faster than the particle marker), and orad (retrograde) washing at ratios <1 (where the solute marker travels slower than the particle marker). We analysed digesta washing in a dataset of 98 mammalian species including man of differen...

2011-01-01

285

Phase change characteristic study of spherical PCMs in solar energy storage  

Energy Technology Data Exchange (ETDEWEB)

This paper investigates the phase change behavior of 65 mol% capric acid and 35 mol% lauric acid, calcium chloride hexahydrate, n-octadecane, n-hexadecane, and n-eicosane inside spherical enclosures to identify a suitable heat storage material. Analytical models are developed for solidification and melting of sphere with conduction, natural convection, and heat generation. Both the models are validated with previous experimental studies. Good agreement was found between the analytical predictions and experimental study and the deviations were lesser than 20%. Heat flux release at the wall, cumulative energy release to the external fluid, are revealed for the best PCM. The influence of the size of encapsulation, initial temperature of the PCM, the external fluid temperature on solidified and molten mass fraction, and the total phase change time are also investigated. (author)

2009-08-15

286

On cosmologically designed modified gravity theories  

CERN Document Server

Versions of parameterized pseudo-Newtonian gravity theories specially designed for cosmology have been introduced in recent cosmology literature. The modifications demand a zero-pressure fluid in the context of versions of modified Poisson-like equation with two different gravitational potentials. We consider such modifications in the context of relativistic gravity theories where the action is a general algebraic function of the scalar curvature, the scalar field, and the kinetic term of the field. In general it is not possible to isolate the zero-pressure fluid component simultaneously demanding a modification in the Poisson-like equation. Only in the small-scale limit we can realize some special forms of the attempted modifications. We address some loopholes in the possibility of showing non-Einstein gravity nature based on pseudo-Newtonian modifications in the cosmological context. We point out that future observations of gravitational weak ...

2010-01-01

287

Omental pedicle flap used to treat a bronchopleural fistula after diaphragma--pericardio-pleuropneumonectomy.  

Science.gov (United States)

In a 47-year-old male patient a bronchopleural fistula was apparent 22 days after extended right-sided diaphragma-pericardio-pleuro-pneumonectomy for pleuramesothelioma. The thoracic cavity was infected. Rethoracotomy was performed and the fistula was closed using an omental pedicle flap. The bronchial stump became tight and the cavity fluid became sterile. No abdominal complications were seen. The patient died 8 months later from malignant pericardial infiltration. The ability of greater omentum to revascularize ischemic tissue, to absorb fluid and to resist local infection is proved and used in several subspecialities of surgery. Nevertheless the use of the greater omentum in the management of bronchopleural fistula has been rarely published. The reported case shows that the closure of a large bronchopleural fistula is possible by using the attributes of the omental tissue. PMID:2264043

1990-10-01

288

Numerical study of thermoelectric characteristics of a planar solid oxide fuel cell with direct internal reforming of methane  

Energy Technology Data Exchange (ETDEWEB)

A three-dimensional mathematical thermo-fluid model coupling the electrochemical kinetics with fluid dynamics was developed to simulate the heat and mass transfer in planar anode-supported solid oxide fuel cell (SOFC). The internal reforming reactions and electrochemical reactions of carbon monoxide and hydrogen in the porous anode layer were analyzed. The temperature, species mole fraction, current density, overpotential loss and other performance parameters of the single cell unit were obtained by a commercial CFD code (Fluent) and external sub-routine. Results show that the current density produced by electrochemical reactions of carbon monoxide cannot be ignored, the cathode overpotential loss is the biggest one among the three overpotential losses, and that the proper decrease of the operating voltage leads to the increase of the current density, PEN structure temperature, fuel utilization factor, fuel efficiency and power output of the ...

2009-01-15

289

Numerical simulation of fluid flow and heat transfer in a concentric tube heat exchanger  

International Nuclear Information System (INIS)

In this paper, numerical simulation of a concentric tube heat exchanger is presented to determine the convective heat transfer coefficient and friction factor in a smooth tube. Increasing the convective heat transfer coefficient can increase heat transfer rate in a concentric tube heat exchanger from a given tubular surface area. This can be achieved by using heat transfer augmentation devices. This work constitutes the initial phase of the numerical simulation of heat transfer from tubes employing augmentation devices, such as twisted tapes, wire-coil inserts, for heat transfer enhancement. A computational fluid dynamics (CFD) simulation tool was developed with CFX software and the results obtained from the simulations are validated with the empirical correlations for a smooth tube heat exchanger. The difficulties associated with the simulation of a heat exchanger augmented with wire-coil inserts are discussed. (author)

2003-05-28

290

Numerical methods for thermal-hydraulics and structure in nuclear engineering  

International Nuclear Information System (INIS)

Designs of nuclear reactor plants aim for high performance under safety consideration. Because of large scale and high pressure/temperature conditions, data from costly mockup tests have been required to verify simulation codes of systems and components. Establishment of design by analysis (DBA) in nuclear engineering is required for development of next generation nuclear reactors. Recent powerful computers and simulation technique enable numerical analyses to predict realistic behaviors of thermo-fluid flow, structure and do on. The present report describes resent simulation results of complex gas-liquid two-phase flow, large scale structure dynamics and fluid-structure interaction. (author)

2008-06-01

291

Nonlinear dynamic analysis of a hybrid squeeze-film damper-mounted rigid rotor lubricated with couple stress fluid and active control  

British Library Electronic Table of Contents (United Kingdom)

The hybrid squeeze-film damper bearing with active control is proposed in this paper and the lubricating with couple stress fluid is also taken into consideration. The pressure distribution and the dynamics of a rigid rotor supported by such bearing are studied. A PD (proportional-plus-derivative) controller is used to stabilize the rotor-bearing system. Numerical results show that, due to the nonlinear factors of oil film force, the trajectory of the rotor demonstrates a complex dynamics with rotational speed ratio s. Poincare maps, bifurcation diagrams, and power spectra are used to analyze the behavior of the rotor trajectory in the horizontal and vertical directions under different operating conditions. The maximum Lyapunov exponent and fractal dimension concepts are used to determine ...

2010-01-01

292

Non-relativistic Fermions, Coadjoint Orbits of \\winf\\ and String Field Theory at $c=1$  

CERN Document Server

We apply the method of coadjoint orbits of \\winf-algebra to the problem of non-relativistic fermions in one dimension. This leads to a geometric formulation of the quantum theory in terms of the quantum phase space distribution of the fermi fluid. The action has an infinite series expansion in the string coupling, which to leading order reduces to the previously discussed geometric action for the classical fermi fluid based on the group $w_\\infty$ of area-preserving diffeomorphisms. We briefly discuss the strong coupling limit of the string theory which, unlike the weak coupling regime, does not seem to admit of a two dimensional space-time picture. Our methods are equally applicable to interacting fermions in one dimension.

1992-01-01

293

Microgravity two-phase flow regime modeling  

Energy Technology Data Exchange (ETDEWEB)

A flow pattern or flow regime is the characteristics spatial distribution of the phases of fluid in a duct. Since heat transfer and pressure drop are dependent on the characteristic distribution of the phases, it is necessary to describe flow patterns in an appropriate manner so that a hydrodynamic or heat transfer theory applicable to that pattern can be chosen. The objective of the present analysis is to create a flow regime map based on physical modeling of vapor/liquid interaction phenomena in a microgravity environment. In the present work, four basic flow patterns are defined: dispersed flow, stratified flow, slug flow, and annular flow. Fluid properties, liquid and vapor flow rates, and pipe size were chosen as the principal parameters. It is assumed that a transition from one flow pattern to another will occur when there is a change in the dominant force which controls that flow pattern. The forces considered in this modeling are ...

1987-01-01

294

Local mass transfer (heat transfer) between wall and fluid in a thin-film evaporator  

Energy Technology Data Exchange (ETDEWEB)

The measurement of local heat transfer coefficients is necessary to record the basic phenomena of heat transfer in thin-film apparatuses. For this reason the so-called electrochemical analogy method was developed and used for this application. The electrochemical method implies a specifically composed electrolyte which substitutes the fluid to be evaporated in the thin-film apparatus. Using the redox electrolyte (0,025 kmol/m/sup 3/ K/sub 4/Fe(CN)/sub 6/ resp. k/sub 4/Fe(CN)/sub 6/ and 2nNaOH) the viscosity was, for the first time, thickened until 0.4 Pa s by the help of hydroxyethyl-cellulose.

1983-03-01

295

Investigation of erosion-corrosion of 3003 aluminum alloy in ethylene glycol-water solution by impingement jet system  

British Library Electronic Table of Contents (United Kingdom)

Erosion-corrosion (E-C) of 3003 aluminum (Al) alloy in ethylene glycol-water solutions were studied by weight-loss and electrochemical measurements as well as surface characterization through an impingement jet system. Al alloy E-C is dominated by erosion components, i.e., pure erosion and corrosion-enhanced erosion, which account for 92-97% of the total E-C rate under the various conditions in this work. Contribution from corrosion components, including pure corrosion and erosion-enhanced corrosion, is slight. With the increase of fluid flow velocity and sand concentration, the total E-C rate increases. Compared with the significant increase of the rates of erosion components, the increase of the rate of corrosion component is negligible. Upon fluid flow, passivity of Al alloy that develo...

2009-01-01

296

Instabilities during liquid migration into superheated hydrothermal systems  

Energy Technology Data Exchange (ETDEWEB)

Hydrothermal systems typically consist of hot permeable rock which contains either liquid or liquid and saturated steam within the voids. These systems vent fluids at the surface through hot springs, fumaroles, mud pools, steaming ground and geysers. They are simultaneously recharged as meteoric water percolates through the surrounding rock or through the active injection of water at various geothermal reservoirs. In a number of geothermal reservoirs from which significant amounts of hot fluid have been extracted and passed through turbines, superheated regions of vapor have developed. As liquid migrates through a superheated region of a hydrothermal system, some of the liquid vaporizes at a migrating liquid-vapor interface. Using simple physical arguments, and analogue laboratory experiments we show that, under the influence of gravity, the liquid-vapor interface may become unstable and break up into fingers.

1995-01-26

297

Inhomogeneous mixmaster universes: Some exact solutions  

Energy Technology Data Exchange (ETDEWEB)

Algorithms for generating new exact solutions of the Einstein-Klein-Gordon field equations, which describe inhomogeneous universes with S/sup 3/ topology of spatial sections, are developed. The known exact vacuum and still-fluid solutions with S/sup 3/ topology are used as an input. The methods developed are further applied to derive inhomogeneous generalizations of Bianchi type IX solutions and inhomogeneous S/sup 3/ Gowdy models with gravitational and scalar waves. It is shown that the new solutions, which are generalizations of the Bianchi type IX models, permit identification of the scalar field with the velocity potential of the stiff irrotational fluid. The latter result is further used to study the growth rate of density perturbations of the isotropic and anisotropic Bianchi type IX universes in a fully nonlinear relativistic regime. The role of anisotropy on the rate of growth of density perturbations is studied in detail.

1983-10-15

298

Inhomogeneous mixmaster universes: Some exact solutions  

International Nuclear Information System (INIS)

Algorithms for generating new exact solutions of the Einstein-Klein-Gordon field equations, which describe inhomogeneous universes with S"3 topology of spatial sections, are developed. The known exact vacuum and still-fluid solutions with S"3 topology are used as an input. The methods developed are further applied to derive inhomogeneous generalizations of Bianchi type IX solutions and inhomogeneous S"3 Gowdy models with gravitational and scalar waves. It is shown that the new solutions, which are generalizations of the Bianchi type IX models, permit identification of the scalar field with the velocity potential of the stiff irrotational fluid. The latter result is further used to study the growth rate of density perturbations of the isotropic and anisotropic Bianchi type IX universes in a fully nonlinear relativistic regime. The role of anisotropy on the rate of growth of density perturbations is studied in detail.

299

Influence of chemical reaction and thermal radiation on the heat and mass transfer in MHD micropolar flow over a vertical moving porous plate in a porous medium with heat generation  

British Library Electronic Table of Contents (United Kingdom)

An analysis is presented for the effects of chemical reaction and thermal radiation on hydromagnetic free convection heat and mass transfer for a micropolar fluid via a porous medium bounded by a semi-infinite vertical porous plate in the presence of heat generation. The plate moves with a constant velocity in the longitudinal direction and the free stream velocity follows an exponentially small perturbation law. A uniform magnetic field acts perpendicularly to the porous surface in which absorbs the micropolar fluid with a suction velocity varying with time. Analytical expressions are computed numerically. Numerical calculations are carried out the purpose of the discussion of the results which are shown on graphs and the effects of the various dimensionless parameters entering into the p...

2009-01-01

300

In-vitro evaluation of corrosion resistance of nitrogen ion implanted titanium simulated body fluid  

International Nuclear Information System (INIS)

Titanium and its alloy Ti6Al4V enjoy widespread use in various biomedical applications because of favourable local tissue response, higher corrosion resistance and fatigue strength than the stainless steels and cobalt-chromium alloy previously used. The study reported in this paper aims to optimize the conditions of nitrogen ion implantation on commercially pure titanium and to correlate the implantation parameters to the corrosion resistance. X-ray photoelectron spectroscopy was used to analyse surface concentration and the implantation processes. An improvement in the electrochemical behaviour of the passive film was shown to occur with nitrogen ion implantation on titanium, in simulated body fluids. (UK).

301

Homogenation of acoustic metamaterials of Helmholtz resonators in fluid  

Energy Technology Data Exchange (ETDEWEB)

By using a two-step homogenization approach, we derive analytical formulas of effective mass density {rho}{sub e} and effective bulk modulus B{sub e} for two- and three-dimensional acoustic metamaterials of Helmholtz resonators (HRs) in fluid. A negative B{sub e} is found at certain frequencies due to the monopolar resonance, leading to a low-frequency acoustic band gap. A unified picture is presented for metamaterials of HRs and three-component metamaterials of negative {rho}{sub e}. Our work supports recent observations in a one-dimensional array of HRs [N. Fang et al., Nat. Mater. 5, 452 (2006)] and presents important high-dimensional extensions for exploring more fascinating phenomena.

2008-05-01

302

High sensitivity and specificity of the C6-peptide ELISA on cerebrospinal fluid in Lyme neuroborreliosis patients  

British Library Electronic Table of Contents (United Kingdom)

Abstract Lyme neuroborreliosis (LNB) is a serious but treatable disease. The diagnosis of LNB poses a challenge to clinicians, and improved tests are needed. The C6-peptide ELISA is frequently used on serum but not on cerebrospinal fluid (CSF). Data on the sensitivity of the C6-peptide ELISA in CSF in patients suffering from LNB have been conflicting. Serum-CSF pairs from 59 LNB patients, 36 Lyme non-neuroborreliosis cases, 69 infectious meningitis/encephalitis controls and 74 neurological controls were tested in a C6-peptide ELISA. With the optimal cut-off of 1.1, the sensitivity of the C6-peptide ELISA for LNB patients in CSF was 95%, and the specificity was 83% in the Lyme non-neuroborreliosis patients, 96% in the infectious controls, and 97% in the neurological controls. These results ...

2011-01-01

303

Heat and fluid flow during the formation of metallic glasses by splat cooling  

Science.gov (United States)

A model is presented for heat and fluid flow during hammer and anvil splat cooling. Predictions are made for the effects of superheat and hammer speed on splat thickness, cooling rate, and subsequent glass formation. The regime of Newtonian heat flow is extended well beyond the previously accepted limiting value of Nusselt number. Measurements of the structure, stability, and thickness of Fe{sub 80}B{sub 20} and Pd{sub 80}Si{sub 20} hammer and anvil splats qualitatively confirm the model prediction. Variations of superheat in shock tube splats produced similar trends to those observed in the hammer and anvil device. In an attempt to vary the equivalent of hammer speed in a shock tube device, an orifice producing a supersonic shock wave was utilized. Significant splat flake thickness reductions resulted as compared to subsonic orifices.

304

Glass-heat-pipe evacuated-tube solar collector  

Science.gov (United States)

A glass heat pipe is adapted for use as a solar energy absorber in an evacuated tube solar collector and for transferring the absorbed solar energy to a working fluid medium or heat sink for storage or practical use. A capillary wick is formed of granular glass particles fused together by heat on the inside surface of the heat pipe with a water glass binder solution to enhance capillary drive distribution of the thermal transfer fluid in the heat pipe throughout the entire inside surface of the evaporator portion of the heat pipe. Selective coatings are used on the heat pipe surface to maximize solar absorption and minimize energy radiation, and the glass wick can alternatively be fabricated with granular particles of black glass or obsidian.

1981-08-06

305

Geothermal heat cycle research supercritical cycle with counterflow condenser in different orientations  

Energy Technology Data Exchange (ETDEWEB)

The Heat Cycle Research Program, which is conducted for the Department of Energy, has as its objective the development of the technology for effecting the improved utilization of moderate temperature geothermal resources. The current testing involves the investigation of binary power cycle performance utilizing mixtures of non-adjacent hydrocarbons as the working fluids, with supercritical vaporization and in-tube condensation of the working fluid. The utilization of these concepts verified here will improve the net geofluid effectiveness (net watt hours plant output per pound of geofluid) about 20% over that of a conventional binary power plant. The major effect in this improvement is the ability to achieve integral, countercurrent condensation. Results are presented for the recent testing including those tests examining the performance of the countercurrent condenser at different tube inclinations and comparison with new design-base computer ...

1988-01-01

306

Forced convective heat transfer in cross-corrugated solar air heaters  

Science.gov (United States)

Forced convective heat transfer in a cross-corrugated channel solar air heater has been studied experimentally using air as a working fluid. The channel was formed by two transversely positioned corrugated sheets and two flat thermally insulated side walls. One corrugated sheet was heated by a radiant heater, while the other was thermally insulated. The fluid velocity and temperature, and the wall temperature and the local heat flux across the heated corrugated sheet were measured for a variety of operating flow rates. Experimental results for the channel geometry have yielded the correlation Nu = 0.0743 (Re)[sup 0.76]. This heat-transfer coefficient is about 2.8 times that of a smooth flat channel. The experiments showed that local heat transfer rate was smaller on the valley of the corrugation than that on the peak. The ratio of the local heat transfer rates on the two locations was related to the Reynolds number.

1994-11-01

307

First derivative of the hard-sphere radial distribution function at contact  

Energy Technology Data Exchange (ETDEWEB)

Molecular dynamics simulations have been carried out of the radial distribution function of the hard sphere fluid for a range of densities in the equilibrium fluid and just into the metastable region. The first derivative of the hard-sphere radial distribution function at contact was computed and its density dependence fitted to a simple analytic form. Comparisons were made with semi-empirical formulae from the literature, and of these the formula proposed by Tao et al (1992 Phys. Rev. A 46 8007) was found to be in best agreement with the simulation data, although it slightly underestimates the derivative at the higher packing fractions in excess of about 0.45. Close to contact, within a few per cent of the particle diameter, the radial distribution function can be represented well by a second order polynomial. An exponential function, which has some useful analytic features, can also be applied in this region.

2006-08-16

308

Experimental investigation of mixed convection heat transfer from longitudinal fins in a horizontal rectangular channel  

British Library Electronic Table of Contents (United Kingdom)

Mixed convection heat transfer from longitudinal fins inside a horizontal channel has been investigated for a wide range of modified Rayleigh numbers and different fin heights and spacings. An experimental parametric study was made to investigate effects of fin spacing, fin height and magnitude of heat flux on mixed convection heat transfer from rectangular fin arrays heated from below in a horizontal channel. The optimum fin spacing to obtain maximum heat transfer has also been investigated. During the experiments constant heat flux boundary condition was realized and air was used as the working fluid. The velocity of fluid entering channel was kept nearly constant (0.15win0.16m/s) using a flow rate control valve so that Reynolds number was always about Re=1500. Experiments were conducted...

2010-01-01

309

Experimental assessment of energy storage via variable speed compressor  

British Library Electronic Table of Contents (United Kingdom)

In this study, usage of a variable speed refrigeration system in latent heat thermal energy storage (LHTES) system is investigated to increase energy storage efficiency. Four different compressor speed control cases are compared to obtain a constant heat transfer fluid (HTF) temperature at the inlet of the energy storage tank. These control cases are (i) control with evaporation temperature, (ii) control with ethylene glycol temperature at the outlet section of evaporator, (iii) control with suction pressure of the compressor and (iv) on/off control. By means of the experimental analysis the best control strategy is obtained as control with Case (ii), in terms of stability of inlet temperature of heat transfer fluid, variations of energy efficiency of LHTES and coefficient of performance (...

2011-01-01

310

Effects of heat loss as percentage of fuel's energy, friction and variable specific heats of working fluid on performance of air standard Otto cycle  

British Library Electronic Table of Contents (United Kingdom)

The objective of this study is to analyze the effects of heat loss characterized by a percentage of the fuel's energy, friction and variable specific heats of working fluid on the performance of an air standard Otto cycle with a restriction of maximum cycle temperature. A more realistic and precise relationship between the fuel's chemical energy and the heat leakage that is based on a pair of inequalities is derived through the resulting temperature. The variations in power output and thermal efficiency with compression ratio, and the relations between the power output and the thermal efficiency of the cycle are presented. The results show that the power output as well as the efficiency where maximum power output occurs will increase with increase of the maximum cycle temperature. The temp...

2008-01-01

311

Effect of the induced magnetic field on peristaltic flow of a couple stress fluid  

Science.gov (United States)

We have analyzed the MHD flow of a conducting couple stress fluid in a slit channel with rhythmically contracting walls. In this analysis we are taking into account the induced magnetic field. Analytical expressions for the stream function, the magnetic force function, the axial pressure gradient, the axial induced magnetic field and the distribution of the current density across the channel are obtained using long wavelength approximation. The results for the pressure rise, the frictional force per wave length, the axial induced magnetic field and distribution of the current density across the channel have been computed numerically and the results were studied for various values of the physical parameters of interest, such as the couple stress parameter ?, the Hartmann number M, the magnetic Reynolds number R and the time averaged mean flow rate ?. Contour plots for the stream and magnetic force functions are obtained and the trapping phenomena for the flow field ...

2008-06-01

312

Dynamic and static error analyses of neutron radiography testing  

Energy Technology Data Exchange (ETDEWEB)

Neutron radiography systems are being used for real-time visualization of the dynamic behavior as well as time-averaged measurements of spatial vapor fraction distributions for two phase fluids. The data in the form of video images are typically recorded on videotape at 30 frames per second. Image analysis of he video pictures is used to extract time-dependent or time-averaged data. The determination of the average vapor fraction requires averaging of the logarithm of time-dependent intensity measurements of the neutron beam (gray scale distribution of the image) that passes through the fluid. This could be significantly different than averaging the intensity of the transmitted beam and then taking the logarithm of that term. This difference is termed the dynamic error (error in the time-averaged vapor fractions due to the inherent time-dependence of the measured data) and is separate from the static error (statistical sampling uncertainty). ...

1999-03-01

313

Diagenesis and porosity development in the carbonate reservoirs in the Ordovician Majiagou Formation, northern Ordos Basin, China  

Energy Technology Data Exchange (ETDEWEB)

The carbonate rocks of the Lower Ordovician Majiagou Formation represent important hydrocarbon reservoirs in the Ordos basin in the western part of the North China plate. Cores and thin sections from more than 60 wells were examined. The main reservoir in the Majiagou Formation consists of fine crystalline dolomite, which was altered by meteoric water during an extended subaerial exposure. Three phreatic zones have been identified in the Majiagou Formation in the northern part of the basin. Oxygen isotopes and fluid inclusion microthermometry data indicates that the porosity developed during the early karst event was considerably reduced by the late-stage, coarse crystalline calcite cements that appear to be related to hydrothermal fluids during deep burial. It was concluded that the main factors that determine the porosity and permeability of these carbonate reservoirs are dolomitization, karstification, and calcite cementation.

2006-07-01

314

Development of in-vessel reflood instrumentation at ORNL  

International Nuclear Information System (INIS)

A program under the sponsorship of the United States Nuclear Regulatory Commission was intiated at the Oak Ridge National Laboratory (ORNL) in late 1977. The program, Advanced Instrumentation for Reflood Studies (AIRS), is charged with developing instrumentation for measurement of in-vessel fluid phenomena in pressurized water reactor reflood facilities. The goal of the ORNL program is to develop techniques and systems for measuring fluid flow in-core, deentrainment in the upper plenum and liquid fallback from the upper plenum into the core. A large portion of the development at ORNL is devoted to the impedance probes for measurement of two-phase flow velocities and void fractions. Film probe development at ORNL is limited to adapting the present techniques to the environment of a reflood facility. As the development progresses on all the measurement techniques, ORNL will fabricate and supply instrument systems to the reflood facilities ...

2004-09-06

315

Development document for proposed effluent limitations guidelines and standards for the coastal subcategory of the oil and gas extraction point source category  

Science.gov (United States)

;Table of Contents: Legal authority; Summary of proposed regulations; Industry definition and waste streams; Industry description; Data and information gathering; Selection of pollutant parameters; Drilling wastes-characterization, control, and treatment technologies; Produced water-characterization, control, and treatment technologies; Miscellaneous waste-characterization, control, and treatment technologies; Cost and pollutant loading determination of drilling fluids and drill cuttings; Compliance cost and pollutant load determination of produced water; Compliance cost and pollutant load determination of well treatment, workover, and completion fluids; Cost and pollutant loading determination of deck drainage; Options selection-rationale and total costs; Pretreatment standards; Non-water quality environmental impacts and other factors; Best Management Practices; and Appendices.

1995-02-01

316

Design of aircraft-carried sampling system for aerial radioactivity monitoring  

International Nuclear Information System (INIS)

This paper presents the development of technical requirements for the design of aircraft-mounted sampling equipment for the airborne radioactivity monitoring. A design concept and internal equipments required for the sampling system will be described in detail to provide information for the development of technical requirements for aircraft-mounted sampling equipment. This will be followed by description of the exterior designing process. Difficulties of designing exterior of the sampling system lie in the fluid dynamics performance of the system. The objective of the design is to maximize the suction flow necessary for achieving high efficiency of radionuclide sampling, while minimizing disturbance to the aircraft which carries the system. The design optimization was performed with the computational fluid dynamics (CFD) code FLUENT. The design options considered here were (1) diameter to head ratio of top and back head, (2) nozzle length and ...

2009-03-01

317

Design and fabrication of a two dimensional valveless micropump  

Energy Technology Data Exchange (ETDEWEB)

The scale-down of a liquid mini-pump (order of 10 mm) to a micrometre scale has been attempted using a novel valveless nozzle-diffuser design and new application of an organic physical vapor-deposited membrane. The micropump employs no moving parts other than the membrane and accomplishes the rectification of fluid flow due to pressure recovery differences in the nozzle and diffuser flow directions. More specifically, liquids flow with less resistance (i.e. conduct more fluid) in the diffuser direction than the nozzle direction, for a given pressure differential. At the micrometre scale, the fabrication of the critical nozzle and diffuser elements was performed by focused ion beam (FIB) microlithography of glass slides. Etched slides were sandwiched to make two-dimensional venturis. Sternme and Sternme noted the importance of a lower Reynolds Number linfit on the desired pressure recovery which challenged the fabrication of this pump design at ...

1995-12-31

318

Combined effect of magnetic field and heat absorption on unsteady free convection and heat transfer flow in a micropolar fluid past a semi-infinite moving plate with viscous dissipation using element free Galerkin method  

British Library Electronic Table of Contents (United Kingdom)

The fully developed electrically conducting micropolar fluid flow and heat transfer along a semi-infinite vertical porous moving plate is studied including the effect of viscous heating and in the presence of a magnetic field applied transversely to the direction of the flow. The Darcy-Brinkman-Forchheimer model which includes the effects of boundary and inertia forces is employed. The differential equations governing the problem have been transformed by a similarity transformation into a system of non-dimensional differential equations which are solved numerically by element free Galerkin method. Profiles for velocity, microrotation and temperature are presented for a wide range of plate velocity, viscosity ratio, Darcy number, Forchhimer number, magnetic field parameter, heat absorption ...

2010-01-01

319

Coenzyme Q10 nanoparticles prepared by a supercritical fluid-based method  

British Library Electronic Table of Contents (United Kingdom)

A supercritical fluid-based method is proposed to produce coenzyme Q10 (CoQ10) nanoparticles. First, CoQ10/polyethylene glycol 6000 composite particles are prepared by a modified PGSS (particles from gas-saturated solutions) process with controlling the flow rate of the gas-saturated solution. Then, CoQ10 nanoparticles are obtained by dissolving the composite particles into water. The effect of experimental variables of the modified PGSS process, including pressure, temperature, flow rate of the gas-saturated solution, and mass fraction of CoQ10, on the CoQ10 particle size and particle size distribution was investigated. Results show that CoQ10 slurry product with a median diameter of 190nm and yield of 89.8% can be prepared at an optimum condition (operating pressure of 25MPa, operating t...

2011-01-01

320

Brine injection studies at Lawrence Berkeley Laboratory  

Energy Technology Data Exchange (ETDEWEB)

As an integral part of DOE/GTD's Brine Injection Program, LBL is developing and demonstrating methods for: (1) designing and analyzing injection tests, (2) predicting and monitoring migration of injected fluids, and (3) optimizing field-wide injection and heat extraction operations in geothermal reservoirs. Computational and well test techniques are being developed (a) to detect and predict the movement of fluids of contrasting temperatures, phase compositions and chemistries in the injected formation, and (b) to characterize the associated physical and chemical processes occurring in the reservoir. LBL's theoretical and field-related brine injection activities in FY 1986 are described, and progress made during FY 1987 is discussed.

1987-01-01

321

Brief guide to the MINC-method for modeling flow and transport in fractured media  

Science.gov (United States)

MINC stands for Multiple INteracting continua.'' It is an approximate method for modeling fluid and heat flow in fractured- porous media, developed by Pruess and Narasimhan (1982, 1985) at the Lawrence Berkeley Laboratory. The method is applicable to flow processes in which an important aspect is the exchange of fluid, heat, or chemical species between fractures and unfractured rock. Examples include production and injection operations in fractured geothermal reservoirs, water-flooding, steamflooding, and other methods for enhanced oil recovery from fractured reservoirs, as well as chemical transport and contaminant migration in fractured rock. MINC can only be applied to media in which the fractures are sufficiently well connected so that a continuum treatment of flow in the fracture network can be made.

1992-05-01

322

Basic study on heat transfer characteristics of liquid Na in a decay-heat removal system of LMFBR  

Energy Technology Data Exchange (ETDEWEB)

A numerical analysis is performed to clarify the heat transfer characteristics of combined convection around the tubes which form a single row perpendicularly arranged to a forced flow in the direction of gravity. A boundary-fitted coordinate transformation technique is adopted to solve the governing equations numerically. It is found in the case of liquid sodium that gravity-induced flow gives no substantial effect to heat transfer augmentation in a low Reynolds number region while it can be sufficiently expected in the ordinary fluids in the same Reynolds number region. This means that such heat transfer augmentation as expected in ordinary fluids can not be realized when crossflow-type heat exchangers installed for decay-heat removal operates in a low Reynolds number region.

1988-02-01

323

Analysis of nonisothermal injection and falloff tests in layered reservoirs  

Energy Technology Data Exchange (ETDEWEB)

The effects of reservoir layering and gravity segregation on nonisothermal injection and falloff tests are investigated. Results show that layering does not affect injection or falloff data if all the layers are permeable and accept fluids from the wellbore. In such cases, the average permeability, skin factor, and distance to the thermal front can be calculated using the techniques developed for homogeneous reservoirs. Special considerations have to be taken for cases where several layers are impermeable or are permeable but do not accept fluids of the well face. In the first case (impermeable layers), knowledge of the total thickness of the permeable layers is required for the existing techniques to be applied successfully. In the second case, the existing techniques cannot be applied, but characteristic responses from injection and falloff test are seen; therefore, this case can be identified easily. 13 refs., 8 figs.

1985-03-01

324

Analysis of WITCH/LINER experiments on heat transfer between gas-agitated steel melt and vertical wall  

Energy Technology Data Exchange (ETDEWEB)

The analysis for the WITCH/LINER experiments was performed to investigate the heat transfer characteristics between the gas-agitated steel melt and the vertical surface. The applicability of heat transfer correlations for a gas-agitated fluid system was examined through the numerical analysis of the one-dimensional heat conduction taking into account the crust formation due to the solidification of the steel melt. The heat transfer correlation developed by Konsetov was modified for the application to fluids with low Prandtl number. The constant in the modified correlation was empirically found mainly through the comparison between the analysis and the experiments under conditions that a churn-turbulent two-phase flow regime was anticipated to form. The modified Konsetov correlation could predict the heat transfer characteristics observed through the experiments in an acceptable level. (author)

1999-10-01

325

An integrated nuclear electro-thermal engine concept for geostationary missions  

International Nuclear Information System (INIS)

A preliminary design for a nuclear electric 'Space Tug' is proposed for use in conjunction with the American Space Shuttle for high energy missions. The vehicle would employ a SNAP 10A/2 or SNAP 8 nuclear reactor derivative for its power supply and slush hydrogen as the working fluid for the electrothermal thrusters. A thermodynamic conversion cycle would be employed for electrical power generation, for which the hydrogen working fluid would perform the duty of the heat sink. The cycle would eliminate the need for heavy waste radiators and improve the overall thermal efficiency. The vehicle promises a considerable payload advantage over a chemical recoverable Tug for geostationary missions. (orig.).

1974-10-14

326

Advanced Distillation Curve Measurement with a Model Predictive Temperature Controller  

British Library Electronic Table of Contents (United Kingdom)

In previous work, several significant improvements in the measurement of distillation curves for complex fluids were introduced. The modifications to the classical measurement provide for (1) temperature and volume measurement(s) of low uncertainty, and most important, (2) a composition-explicit data channel in addition to the usual temperature?volume relationship. This latter modification is achieved with a new sampling approach that allows precise qualitative as well as quantitative analyses of each fraction, on the fly. In the new approach, the distillation temperature is measured in two locations. The temperature is measured in the usual location, at the bottom of the take-off in the distillation head, but it is also measured directly in the fluid. We have further modified our developm...

2006-01-01

327

A strategy of implementation of the improved constitutive equations for the advanced subchannel code  

International Nuclear Information System (INIS)

To develop the advanced subchannel analysis code, the dominant factors that influence the boiling transitional process must be taken into account in the mechanistic constitutive equations based on the flow geometries and the fluid properties. The dominant factors that influence the boiling transitional processes are (1) the gas-liquid re-distribution by cross flow, (2) the liquid film dryout, (3) the two-phase flow regime transition, (4) the droplet deposition, and (5) the spacer-droplet interaction. At first, we indicated the strategy for the development of the constitutive equations for the five dominant factors based on the experimental database by the latest measurement technique and the latest computational fluid dynamics method. Then, the problems of the present constitutive equations and the improvement plan of the constitutive equations were indicated. Finally, the layered structure for the two-phase/three-field subchannel code ...

2004-10-04

328

A fluid structure coupling of the Ariane-5 nozzle section during start phase by detached eddy simulation  

British Library Electronic Table of Contents (United Kingdom)

Concerning the requirements of future rocket technologies, providing a cost-efficient access to orbit as well as an increase in system reliability, a deeper insight into the unsteady phenomena during ascent of modern launchers is essential. Unsteady interactions and resonances of the turbulent separated launcher wake and the nozzle structure play an important role for the design of future main stage propulsion systems. The so-called buffeting coupling phenomenon is one of the main challenges during ascent. In the present study, a coupled simulation of the afterbody of the Ariane-5 launcher with a realistic structural and aerodynamic representation of different nozzle configurations is carried out. On the computational fluid dynamics side, unsteady detached eddy simulations are coupled with...

2011-01-01

329

A basic study on heat transfer characteristics of liquid Na in a decay-heat removal system of LMFBR  

International Nuclear Information System (INIS)

A numerical analysis is performed to clarify the heat transfer characteristics of combined convection around the tubes which form a single row perpendicularly arranged to a forced flow in the direction of gravity. A boundary-fitted coordinate transformation technique is adopted to solve the governing equations numerically. It is found in the case of liquid sodium that gravity-induced flow gives no substantial effect to heat transfer augmentation in a low Reynolds number region while it can be sufficiently expected in the ordinary fluids in the same Reynolds number region. This means that such heat transfer augmentation as expected in ordinary fluids can not be realized when crossflow-type heat exchangers installed for decay-heat removal operates in a low Reynolds number region. (author).

1988-01-01

330

[Peritonitis in the course of peritoneal dialisis caused by Haemophilus influenzae with BLNAR phenotype].  

Science.gov (United States)

Most common bacterial species causing peritonitis in the course of peritoneal dialysis (PDP) are coagulase-negative staphylococci, Staphylococcus aureus and streptococci. Haemophilus influenzae is rarely associated with PDP. Hereby we present the first known case of APD-associated peritonitis caused by non-type able H. influenzae (NTHi) presenting the beta-lactamase negative, ampicillin-resistant (BLNAR) phenotype. An 18 year old boy who had been treated with the APD for 12 months due to SLE was admitted in good general condition with diagnosis of PDP. Standard diagnostic and therapeutical procedures were initiated. Dialysis fluid was turbid with cytosis of 435 WBC/ml. From dialysis fluid pure culture of Gram-negative coccobacillus was isolated. The isolate was identified as a BLNAR phenotype. The same bacterium was isolated from nasal swab. Blood cultures were negative. After evaluation of antimicrobial susceptibility the treatment was changed ...

2009-04-01

331

Weibel and Two-Stream Instabilities for Intense Charged Particle Beam Propagation through Neutralizing Background Plasma  

Energy Technology Data Exchange (ETDEWEB)

Properties of the multi-species electromagnetic Weibel and electrostatic two-stream instabilities are investigated for an intense ion beam propagating through background plasma. Assuming that the background plasma electrons provide complete charge and current neutralization, detailed linear stability properties are calculated within the framework of a macroscopic cold-fluid model for a wide range of system parameters.

2004-04-09

332

Upgrading the ampacity of HPFF pipe-type cable circuits  

Energy Technology Data Exchange (ETDEWEB)

The upgrading of several 69 kV pipe-type cable feeders on the Potomac Electric Power Company (PEPCo) transmission cable system is discussed. The methods used for the ampacity calculation are described. The fluid circulation approach required to meet the feeder emergency load requirements are discussed. For the feeders that were in service for approximately 40 years, a system life evaluation was performed.

1994-12-31

333

Unsteady flow of an incompressible fluid in a horizontal porous medium with suction  

International Nuclear Information System (INIS)

A theoretical analysis of two-dimensional unsteady flow in a porous medium bounded by a horizontal wall is presented as a perturbation on a basic flow. It is assumed that the perturbation is occasioned by a sudden suction at the wall. Even for a highly permeable medium the characteristic Reynolds number in porous media flow is usually small and asymptotic solutions are developed by the Laplace transform technique. It is observed that the perturbed shear stress at the wall decays exponentially with time. (author). 5 refs.

2000-03-01

334

Two-phase fluid flow measurements in small diameter channels using real-time neutron radiography  

International Nuclear Information System (INIS)

A series of real-time, neutron radiography, experiments are ongoing at the Texas A and M Nuclear Science Center Reactor (NSCR). These tests determine the resolving capabilities for radiographic imaging of two phase water and air flow regimes through small diameter flow channels. Though both film and video radiographic imaging is available, the real-time video imaging was selected to capture the dynamic flow patterns with results that continue to improve. (author)

1994-04-05

335

Thermo-hydraulic design of Chinese helium cooled solid breeder blanket for ITER-TBM  

International Nuclear Information System (INIS)

To further optimize thermo-hydraulic capability of HCSB-TBM, two different thermo-hydraulic schemes would be proposed and investigated by relevant calculating and simulating of thermo-dynamics in normal and peak heat flux condition. With computational fluid dynamics (CFD) code FLUENT, the actual temperature distribution of key components of HCSB-TBM is simulated. (authors)

2009-06-01

336

The postal service wants to move away from diesel transport. Die Post will sich von ihren Dieseltransportern trennen  

Energy Technology Data Exchange (ETDEWEB)

By the year 2000, the Postal Service aims to reduce its diesel transport by around 15000 vehicles. The advisory service, Detecon, is reviewing alternatives for postal deliveries as part of the ''Post 2000'' initiative. One such system is an electric-powered vehicle with a zinc-air battery from the Israeli firm Electric Fluid Limited (EFL). (orig.)

1994-01-05

337

The Percus-Yevick theory is alive and well  

Science.gov (United States)

The pressure of a 6:12 fluid is obtained from the Percus-Yevick theory at the temperature kT/? = 1.35. The energy equation results are in excellent agreement with machine calculation results in contrast to the pressure and compressibility equation results. Present address: Diffusion Research Unit, The Australian National University, Canberra, ACT, Australia.

1970-01-01

338

The Friction of Vehicle Brake Tandem Master Cylinder  

International Nuclear Information System (INIS)

The behaviour of an elastomeric seal for vehicle brake Tandem master cylinder is measured and analyzed in temperature and brake fluids changed. Working conditions are simulated for different piston rod velocity and cylinder supply pressure, in temperature rising, brakefluid boundary and Nanoaluminum oxide brakefluid oxide brakefluid lubrication. The result shows that Nanoaluminum oxide brakefluid with its ball shape can highly reduce friction coefficient to avoid seal excessive wear and reduce slick slip in brake applications.

2006-10-01

339

Solar collectors with tubes partially filled with porous substrates  

Energy Technology Data Exchange (ETDEWEB)

In this work, the thermal performance of a conventional collector is improved by inserting porous substrates at the inner walls of the collector tubes. The porous substrates improve the convective heat transfer coefficient between the tube wall and the fluid. This improvement is investigated numerically and its effects on the efficiency and the useful gain of the collector are evaluated. It is found that inserting the porous substrate may raise the collector efficiency considerably, especially at high values of the overall heat loss coefficient.

1999-02-01

340

Pumping manual/7th edition  

Energy Technology Data Exchange (ETDEWEB)

This book includes the latest developments and covers pump performance, selection and operations, materials, seals and packings, effective fluid characteristics, filtration, piping systems, economics, valves, instrumentation, automatic controls, power transmission equipment, pump and pipeline heating, and more. An extensive data section contains formulas, charts, symbols, nomographs, and standard specification documents.

1984-01-01

341

Processing and Electrochemical Property Characterization of Nano porous Electrodes for Sustainable Energy Applications  

International Nuclear Information System (INIS)

Preparation and electrocatalytic reactions of nano porous materials in biodegradable fluids were studied. Electrochemical etching was conducted to selectively extract metallic elements from alloys to form porous structures. Electrocatalytic properties of the porous electrodes were characterized. Comparative studies on the electrochemical activities of the nano porous metallic electrodes with bulk metallic wire catalysts were performed. It is found that the current density at the nano porous electrode is three times higher than that of the bulk electrode

2009-01-01

342

Pressure surge analyses for conventional and nuclear power plants. Druckstossanalysen fuer konventionelle und nukleare Kraftwerke  

Energy Technology Data Exchange (ETDEWEB)

There is need of pressure surge analyses when valves or pumps are activated or piping systems fail (pipe rupture). Based on actual problems the influences of boundary conditions upon fluid simulation results are discussed. Hints concerning realistic dynamic analyses of piping systems are presented. Some of the simulations results are compared with measurements. (orig.)

1993-09-01

343

Polymer depletion-induced slip near an interface  

Energy Technology Data Exchange (ETDEWEB)

A quantitative description is proposed for the depletion-induced slip thickness and velocity profile of a polymer solution near the wall-fluid interface in simple shear flow. The inhomogeneous polymer density profile at a flat wall is inserted into the equations of motion for the flow of a polymer solution near the flat wall. The theory is in quantitative agreement with simulation results. (letter to the editor)

2005-01-19

344

PIV measurements of flow structures in a spray dryer  

DEFF Research Database (Denmark)

Stereoscopic Particle Image Velocimetry (PIV) measurements are made in horizontal planes in a simplified scale model of a spray dryer using water as fluid. The sample rate was sufficient to resolve phenomena at lower frequencies. Data reveal asymmetric velocity fields in both mean fields and dynamics. Data were analysed using Proper Orthogonal Decomposition (POD). An important periodic event is an elongation of the jet core cross section that results in a downstream displacement of the jet towards the chamber wall.

2011-01-01

345

Offshore: North Sea facility gets the CETCO solution  

British Library Electronic Table of Contents (United Kingdom)

CETCO Oilfield Services, suppliers of environmental systems, have undertaken a project to treat contaminated water returns on a Floating, Production, Storage and Offloading (FPSO) facility in the North Sea. The solution sees fluids treated during oil well clean-up operations, reducing the potential for overboard oil discharges, and resulting production upsets.

2006-01-01

346

Nonisothermal Flows of Viscoelastic Fluids: Thermodynamics, Analysis and Numerical Simulation (Niet-Isotherme Stroming van Visco-Elastische Vloeistoffen: Thermodynamica, Analyse en Numerieke Simulatie).  

Science.gov (United States)

The primary of this thesis is the derivation of nonisothermal equations for isotropic viscoelastic materials with the help of the thermodynamics. Because the description of all phenomena would be too ambitious for one thesis, the area of investigation has...

1996-01-01

347

Noise Shielding Using Acoustic Metamaterials  

International Nuclear Information System (INIS)

We exploit theoretically a class of rectangular cylindrical devices for noise shielding by using acoustic metamaterials. The function of noise shielding is justified by both the far-field and near-field full-wave simulations based on the finite element method. The enlargement of equivalent acoustic scattering cross sections is revealed to be the physical mechanism for this function. This work makes it possible to design a window with both noise shielding and air flow. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

2010-03-15

348

New advances in mitigating environmental impact of pipe-type cables  

Energy Technology Data Exchange (ETDEWEB)

Through a comprehensive and aggressive research program Consolidated Edison Company of New York, Inc. (Con Edison) has designed, developed, and installed several new products to address the environmental impact of dielectric fluid from pipe-type cable systems. These include: On Line Leak Detection, Leak Location, Retractable Flow Direction Indicator, Full Stop Joints, and Transition Joints. This paper describes the application of the aforementioned products on the Con Edison underground transmission system.

1999-04-01

349

National Metal Casting Research Institute final report. Volume 2, Die casting research  

Energy Technology Data Exchange (ETDEWEB)

Four subprojects were completed: development and evaluation of die coatings, accelerated die life characterization of die materials, evaluation of fluid flow and solidification modeling programs, selection and characterization of Al-based die casting alloys, and influence of die materials and coatings on die casting quality.

1994-06-01

350

Modeling of turbulent bubbly flows; Modelisation des ecoulements turbulents a bulles  

Energy Technology Data Exchange (ETDEWEB)

The two-phase flows involve interfacial interactions which modify significantly the structure of the mean and fluctuating flow fields. The design of the two-fluid models adapted to industrial flows requires the taking into account of the effect of these interactions in the closure relations adopted. The work developed in this thesis concerns the development of first order two-fluid models deduced by reduction of second order closures. The adopted reasoning, based on the principle of decomposition of the Reynolds stress tensor into two statistically independent contributions turbulent and pseudo-turbulent parts, allows to preserve the physical contents of the second order relations closure. Analysis of the turbulence structure in two basic flows: homogeneous bubbly flows uniform and with a constant shear allows to deduce a formulation of the two-phase turbulent viscosity involving the characteristic scales of bubbly turbulence, as well as an ...

2005-03-15

351

Metabolomics in Lung Inflammation: A High Resolution 1H NMR Study of Mice Exposed to Silica Dust  

UK PubMed Central (United Kingdom)

Here we report the first 1H NMR metabolomics studies on excised lungs and bronchoalveolar lavage fluid (BALF) from mice exposed to crystalline silica. High resolution 1H...Full Text Available

2008-01-01

352

Mathematical two-dimensional model for three-phase filtering of compressible fluids  

Energy Technology Data Exchange (ETDEWEB)

A mathematical model is proposed for three-phase filtering which is a particular case of a more general model of filtering multiple component mixtures and makes it possible to describe three-phase filtering flows under conditions where the pressure of saturation is variable in time and in space. In the proposed model, the system of unknown functions is selected so that it makes it possible to trace fairly simply the pressure of saturation and to compute the corresponding equation coefficients.

1982-01-01

353

Manual corrosion  

Energy Technology Data Exchange (ETDEWEB)

In the aim to fight against tubes corrosion of geothermal wells which exploit the aquifer of Dogger reservoir in the Parisian basin, injection of corrosion inhibitors in the geothermal fluid has been generalized since 1989 by using an additive injection tube in the bottom of the well, allowing the protection of the two wells from the geothermal doublet. 3 annexes. 46 refs. 13 tabs. 9 figs.

1994-09-01

354

Local analysis of three-dimensional air cooled condenser using a two-phase flow diagram  

Energy Technology Data Exchange (ETDEWEB)

This paper is concerned with the development and application of an analytical method for the performance prediction of air cooled condensers. A local analysis is employed in which the condenser is considered as a matrix of small basic heat transfer modules. For each element, local film coefficients for both the air and the condensing fluid are determined according to the existing local conditions, including the two-phase flow regime. The paper considers an application of the method to heat pump condensing.

1983-07-01

355

Jet cutting and cleaning bibliography  

Energy Technology Data Exchange (ETDEWEB)

This bibliography includes over 600 references (with abstracts) on all aspects of waterjet cutting and cleaning. The references are listed under the following chapter headings: fluid mechanics of jets; jet impact; equipment; jet cleaning; jet cutting; civil engineering; mining and tunnelling; precision cutting; underwater; safety; and bibliographies. Separate author and corporate source indexes are provided.

1988-01-01

356

Introduction to corrosion of bioimplants  

British Library Electronic Table of Contents (United Kingdom)

The review provides a general idea about the types of metallic alloys and the pure metals used as implant materials in dental and orthopedic surgery. Their corrosive behavior in both real solutions and various media that model human biological fluids is described. Based on the literature data, it is concluded that multicomponent alloys containing titanium, niobium, zirconium, tungsten, molybdenum, aluminum, and silicon are the most resistant to corrosion. Implants made of different types of stainless steel are preferred when manufacturing orthopedic devices for short-term use.

2011-01-01

357

Intrasphenoid cephalocele: MRI in two cases  

Energy Technology Data Exchange (ETDEWEB)

The intrasphenoid form of basal cephalocele is uncommon. We describe the clinical, CT and MRI findings in two cases presenting in middle age with persistent cerebrospinal fluid rhinorrhoea. Emphasis is placed upon the imaging findings which aid in discrimination of intrasphenoidal cephalocele from more common causes of a sphenoid sinus mass. (orig.)

1999-07-01

358

Imaging findings of central nervous system neuroepithelial cysts  

Energy Technology Data Exchange (ETDEWEB)

Neuroepithelial cysts are rare and mostly asymptomatic cerebrospinal fluid (CSF)-like cysts. We describe herein the imaging findings in five patients with neuroepithelial cysts. Two cases of proven and three of presumed neuroepithelial cysts are presented. Three of five are located in the thalamus, a location which is not characteristic for neuroepithelial cysts. In the case of incidental finding of asymptomatic neuroepithelial cyst, clinical and radiological follow-up is indicated and surgical intervention is not necessarily warranted. (orig.) With 5 figs., 6 refs.

1998-05-01

359

Heat transfer augmentation by interrupted surfaces - Experimental considerations  

International Nuclear Information System (INIS)

An experimental study was undertaken to determine for the turbulent regime the heat transfer and fluid flow characteristics of a heat exchange array of unperforated, and perforated brass plates with 33% of the plate area open. In both cases, the plates were aligned parallel to the flow direction. For the flow conditions examined, the results showed enhancement of heat transfer and friction factor for the perforated array.

1987-08-01

360

Heat and Kinetic Theory in 19th-Century Physics Textbooks The Case of Spain  

CERN Document Server

Spain was a scientifically backward country in the early 19th-century. Thecauses were various political events, the War of Independence, and the reign ofFernando VII. The introduction of contemporary physics into textbooks wastherefore a slow process. An analysis of the contents of 19th-century Spanishtextbooks is here presented, centred on imponderable fluids, the concept ofenergy, the mechanical theory of heat, and the kinetic theory of gases.

2001-01-01

361

Gravitational fields with space-times of Binachi type IX  

International Nuclear Information System (INIS)

Spatially homogeneous space-times of Bianchi type IX are considered. A general scheme for the derivation of exact solutions of Einstein's equations corresponding to perfect fluid plus pure radiation fields is outlined. Some simple rotating Bianchi type IX cosmological models are presented. The details of these solutions are also discussed. 9 refs. (author).

362

Generalized correlation for condensation on vertical fluted surfaces  

Energy Technology Data Exchange (ETDEWEB)

A correlation was developed for laminar film condensation on vertical fluted surfaces. The theoretical analysis of Panchal and Bell was used for defining important physical property groups. The experimental data of Combs et al. were used to validate the proposed correlation. The experimental database used in the present study included four flute geometries that could be approximated to cosine-type flutes and seven fluids. The resulting correlation can predict the average condensate heat transfer coefficient within {+-}20%.

1994-10-01

363

Fuel levelling  

International Nuclear Information System (INIS)

In the case of a release of residual power and fragmenting following a hypothetical accident the applied powers are small. The boiling in the fluid in the bed promotes leveling and the angles of repose obtained are very small. For a specific power in water of 3.1 W/cm_3 a limiting angle of repose of less than 2 degrees is obtained after a time interval of between 1 and 3 hours. EDULCOREE-and ETABUL-research programs are carried out. (DG).

364

Explosives for mining  

Energy Technology Data Exchange (ETDEWEB)

The explosive known under the name Saletrol (mixture of ammonium nitrate and hydrocarbon fuel or a mixture of ammonium nitrate, hydrocarbon fuel and aluminum powder) is characterized by the absence of physical stability during storage (the oily fluid flows from the upper layers of the explosive downward) and as a consequence of this, decrease in the required effectiveness of blasting and increased release of toxic gaseous blasting products. In order to eliminate this shortcoming, lightening clay is added to Saletrol in a quantity of 3-12% by weight of the total explosive mass.

1982-07-31

365

Experimental investigation for fluid flow and heat transfer in a rotating tube with twisted-tape inserts  

Energy Technology Data Exchange (ETDEWEB)

Experimental investigation was carried out for friction factor and heat transfer coefficient in the case of a rotating tube with a twisted-tape insert for heat transfer augmentation. The data obtained were compared with existing data for a stationary tube with a twisted-tape insert. It has been observed that the enhancement in heat transfer offsets the rise in friction factor due to rotation, with respect to a plain tube under stationary conditions. A correlation has been proposed for the data obtained.

1995-04-01

366

Enhanced heat transfer through oscillatory flow  

Energy Technology Data Exchange (ETDEWEB)

The enhancement of longitudinal heat transfer by means of fluid pulsation in a pipe has been investigated analytically and numerically, including the transient state. The effects of pulsation amplitude, frequency, and pipe length on thermal properties such as effective thermal diffusivity and delay time are clarified. Their effects on numerical calculations are also presented and suggestions for efficient numerical calculations of this problem are made concerning the combination of parameters.

1994-03-01

367

Design concepts and preliminary economics for coal/oil shale combustion retort systems  

Energy Technology Data Exchange (ETDEWEB)

New Brunswick has appreciable fossil-fuel reserve potential, particularly in oil shales and to a lesser extent in high-sulfur coal. Each of these resources on their own, however, has problems which could restrict their development. To offset these problems it is proposed that coal and oil shale resources can be used together to overcome these difficulties and effect an attractive, economically viable, energy recovery system. One way is o use coal/oil shale blends, rather than the more conventional coal/limestone mixtures, as feed to fluid-bed combustors for steam generation. The sulfur from the coal is fixed on the spent shale, with the shale combustibles contributing to thermal output. Similarly, oil shale can be used in place of limestone as a combustion scrubber medium to clean emissions from existing conventional coal-fired plants. Several scenarios for the co-use of high-sulfur coal and oil shale are proposed in this report. All involve recovery of energy from ...

1982-04-04

368

Design concept and testing of an in-bundle gamma densitometer for subchannel void fraction measurements in the THTF electrically heated rod bundle  

International Nuclear Information System (INIS)

A design concept is presented for an in-bundle gamma densitometer system for measurement of subchannel average fluid density and void fraction in rod or tube bundles. This report describes (1) the application of the design concept to the Thermal-Hydraulic Test Facility (THTF) electrically heated rod bundle; and (2) results from tests conducted in the THTF.

369

Deposition and removal of sub-micron particles of magnetite at the surface of alloy 800. AECL research No. AECL-11015  

Energy Technology Data Exchange (ETDEWEB)

This report measured the rate of isothermal deposition of sub-micron particles of magnetite onto the surface of Alloy 800 at pH of 4.2-9.3 at Re=10,000 and a fluid temperature of 25C. Deposition is modelled as a two-step process, the transport of particles to the surface region followed by attachment to the surface.

1994-12-31

370

Continuous flow dielectrophoretic particle concentrator  

Energy Technology Data Exchange (ETDEWEB)

A continuous-flow filter/concentrator for separating and/or concentrating particles in a fluid is disclosed. The filter is a three-port device an inlet port, an filter port and a concentrate port. The filter separates particles into two streams by the ratio of their dielectrophoretic mobility to their electrokinetic, advective, or diffusive mobility if the dominant transport mechanism is electrokinesis, advection, or diffusion, respectively.Also disclosed is a device for separating and/or concentrating particles by dielectrophoretic trapping of the particles.

2007-04-17

371

Construction - laying and installation techniques for extruded and self contained fluid filled cable systems  

Energy Technology Data Exchange (ETDEWEB)

The focus of general public concern on the environment results in the use of underground lines being considered since they offer alternative or interesting complementary solutions for the bulk transmission of electrical energy. This leads to the installation of underground cables in some areas, where overhead lines would automatically have been considered in the past.

2001-07-01

372

Advanced distillation curve measurements for corrosive fluids: Application to two crude oils  

Energy Technology Data Exchange (ETDEWEB)

We have recently introduced several important improvements in the measurement of distillation curves for complex fluids. The modifications include a composition-explicit data channel for each distillate fraction (for both qualitative and quantitative analysis) and corrosivity assessment of each distillate fraction. The composition-explicit information is achieved with a new sampling approach that allows precise qualitative as well as quantitative analyses of each fraction, on the fly. We have applied the new method to a variety of fluids, including simple n-alkanes, rocket propellant, gasoline, jet fuels, and a hydrocarbon fluid made corrosive with dissolved hydrogen sulfide. In the current contribution, we present the application of the advanced distillation curve method to two samples of crude oil. A primary motivation behind the work is to precisely measure the distillation curves of these oils using our advanced ...

2008-10-15

373

Acoustic wave propagation in fluid metamaterial with solid inclusions  

CERN Document Server

Acoustic waves propagation of in composite of water with embedded double-layered silicone resin/silver rods is considered. Approximate values of effective dynamical constitutive parameters are obtained. Frequency ranges of simultaneous negative constitutive parameters are found. Localized surface states on the interface between metamaterial and ``normal'' material are found. Doppler effect in metamaterial is considered. Presence of anomalous modes is shown.

2010-01-01

374

Ab initio calculations in a uniform magnetic field using periodic supercells  

Energy Technology Data Exchange (ETDEWEB)

We present a formulation of ab initio electronic structure calculations in a finite magnetic field, which retains the simplicity and efficiency of techniques widely used in first principles molecular dynamics simulations, based on plane-wave basis sets and Fourier transforms. In addition we discuss results obtained with this method for the energy spectrum of interacting electrons in quantum wells, and for the electronic properties of dense fluid deuterium in a uniform magnetic field.

2003-10-21

375

A thermal valve heat flux control device  

International Nuclear Information System (INIS)

In order to evacuate the residual power in a nuclear reactor, a thermal valve system is presented for the modification of the heat exchange conditions at the pool exchanger level, which avoids the use of mechanical valves on the pipes. The system involves a vessel containing the exchanger, with openings at the upper end of the vessel and means for feeding the fluid at the lower end, and means for controlling the opening width.

1994-10-05

376

A review of heat exchanger tube bundle vibrations in two-phase cross-flow  

International Nuclear Information System (INIS)

Flow-induced vibration is an important concern to the designers of heat exchangers subjected to high flows of gases or liquids. Two-phase cross-flow occurs in industrial heat exchangers, such as nuclear steam generators, condensers, and boilers, etc. Under certain flow regimes and fluid velocities, the fluid forces result in tube vibration and damage due to fretting and fatigue. Prediction of these forces requires an understanding of the flow regimes found in heat exchanger tube bundles. Excessive vibrations under normal operating conditions can lead to tube failure. Relatively little information exists on two-phase vibration. This is not surprising as single-phase flow induced vibration; a simpler topic is not yet fully understood. Vibration in two-phase is much more complex because it depends upon two-phase flow regime, i.e. characteristics of two-phase mixture and involves an important consideration, which is the void fraction. The effect of ...

2004-05-01

377

A non-invasive approach for the determination of rumen pH  

Environmental Research Database

DescriptionAt present, measurement of rumen pH for differnt diets and feeding regimes is only possible through direct sampling of the rumen fluid. Such invasive procedures are not practical at the farm level and they have ethical implications for research programmes. This approach also has limitations to its reliability due to spatial variations in acidity within the rumen. Mathematical modelling offers a non-invasive real-time alternative for monitoring rumen pH, and the purpose of the research propose [continued...

2004-01-31

378

Proposal to neutralize acid fluids from wells in the Los Humeros, Pue., geothermal field; Propuesta para la neutralizacion de fluidos acidos provenientes de pozos del campo geotermico de Los Humeros, Pue.  

Energy Technology Data Exchange (ETDEWEB)

Neutralizing an acidic fluid consists of adding a sodium hydroxide solution to neutralize the H group of acids, therefore increasing the pH. The injection of sodium hydroxide has to be continuous and at a proper depth inside the well to protect against the corrosion of casing and surface equipment. Neutralization is a common practice used in geothermal fields, such as at The Geysers in the US and Miravalles in Costa Rica-places where aggressive fluids cause problems for extracting and using geothermal fluids commercially. A zone surrounding wells H-4, H-16 and H-29 in the northern section of the Los Humeros, Pue., geothermal field, known as the Colapso Central, has shown evidence of aggressively acidic fluids. Several wells drilled in the area had to be repaired, thus plugging and isolating the deepest production zones. Well H-43 was drilled two years ago in the northern zone of the field, and even ...

2009-07-15

379

The GEOFLOW experiment missions in the Fluid Science Laboratory on ISS  

Science.gov (United States)

The GEOFLOW I experiment has been successfully performed on the International Space Sta-tion (ISS) in 2008 in the Columbus module in order to study the stability, pattern formation and transition to turbulence in a viscous incompressible fluid layer enclosed in two concentric co-rotating spheres subject to a radial temperature gradient and a radial volumetric force field. The objective of the study is the experimental investigation of large scale astrophysical and geophysical phenomena in spherical geometry stipulated by rotation, thermal convections and radial gravity fields. These systems include earth outer core or mantle convection, differen-tial rotation effects in the sun, atmosphere of gas planets as well as a variety of engineering applications. The GEOFLOW I experimental instrument consists of an experiment insert for operation in the Fluid Science Laboratory, which is part of the Columbus Module of the ISS. It was first launched in ...

2010-01-01

380

Two-phase flow modeling in the rod bundle subchannel analysis; Modelisation d'ecoulement a deux phases dans l'analyse du sous-canal de grappe d'assemblages  

Energy Technology Data Exchange (ETDEWEB)

In order to practice a design-by-analysis of thermohydraulics design of BWR fuel rod bundles, the subchannel analysis would play a major role. There, the immediate concern is improvement in its predictive capability of CHF due in particular to the film dryout (boiling transition phenomena: BT) on the fuel rod surface. Constitutive equations in the subchannel analysis formulation are responsible for the quality of calculated results. The constitutive equations are a result of integration of the local and instantaneous description of two-phase flows over the subchannel control volume. In general, they are expressed in terms of subchannel-control-volume- as well as area-averaged two-phase flow state variables. In principle the information on local and instantaneous physical phenomena taking place inside subchannels must be counted for in the algebraic form of the equations on the basis of a more mechanistic modeling approach. They should include also influences of the multi-dimensional ...

2006-07-01

381

Two-phase flow modeling in the rod bundle subchannel analysis  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows:In order to practice a design-by-analysis of thermohydraulics design of BWR fuel rod bundles, the subchannel analysis would play a major role. There, the immediate concern is improvement in its predictive capability of CHF due in particular to the film dryout (boiling transition phenomena: BT) on the fuel rod surface. Constitutive equations in the subchannel analysis formulation are responsible for the quality of calculated results. The constitutive equations are a result of integration of the local and instantaneous description of two-phase flows over the subchannel control volume. In general, they are expressed in terms of subchannel-control-volume- as well as area-averaged two-phase flow state variables. In principle the information on local and instantaneous physical phenomena taking place inside subchannels must be counted for in the algebraic form of the equations on the basis of a more mechanistic modeling approach. They should include also ...

2004-07-01

382

Two-phase flow modeling in the rod bundle subchannel analysis  

International Nuclear Information System (INIS)

In order to practice a design-by-analysis of thermohydraulics design of BWR fuel rod bundles, the subchannel analysis would play a major role. There, the immediate concern is improvement in its predictive capability of CHF due in particular to the film dryout (boiling transition phenomena: BT) on the fuel rod surface. Constitutive equations in the subchannel analysis formulation are responsible for the quality of calculated results. The constitutive equations are a result of integration of the local and instantaneous description of two-phase flows over the subchannel control volume. In general, they are expressed in terms of subchannel-control-volume- as well as area-averaged two-phase flow state variables. In principle the information on local and instantaneous physical phenomena taking place inside subchannels must be counted for in the algebraic form of the equations on the basis of a more mechanistic modeling approach. They should include also influences of the multi-dimensional ...

2006-01-01

383

Ultrasonography and Computerized Tomography in the diagnosis of complex abdominal lesions  

International Nuclear Information System (INIS)

Complex abdominal lesions include a variety of pathologies, such as septated, infected, and hemorrhagic cysts, abscesses, tumors, and fluid collections of different ethiology. These lesions present diagnostic difficulties with both Ultrasonography (US) and Computed Tomography (CT), since findings may not be present or, when present, are not specific. Keeping these limitations in mind, we evaluated 105 patients (111 abdominal lesions) with both US and CT in order to compare their adequacy in predicting the nature of the lesion. On the basis of US and CT results, complex abdominal lesions were divided in four classes: class I includes 43 cases in which both examinations gave the same contribution to the definition of the nature of the lesion, class II (14 lesions, mainly sperimentated cysts), in which US was superior to CT, class III includes 45 cases of hemorrhagic cysts, abscesses, fluid collections and, less frequently, cystic tumors; class IV ...

1988-01-01

384

Treatment of produced water using hydrocyclones; Tratamento de agua produzida usando hidrociclone  

Energy Technology Data Exchange (ETDEWEB)

Beyond a great number of applications in mineral process, the hydrocyclone separation has been used recently in an increasing number of fields, such as: environmental engineering, petrochemical engineering, food engineering, electrochemical engineering, pulp bioengineering, processes and paper industries, among others. Nowadays, the produced water is treated and then reinjected in the surface and also in return to the formation. In the offshore platforms, the produced water can be directly discarded in the ocean, since the dispersed phase concentration (oil) is according to Brazilian regulating agency limits. The basic principle used in hydrocyclone separation is the centrifugal sedimentation machine: the suspended particles are submitted to centrifugal acceleration, which separates them from the fluid. The basic geometry of a hydrocyclone consists of four parts: a cylindrical section for feeding, a conical section for swirling, an overflow and an under flow. The ...

2008-07-01

385

Transition from mixed to forced convection for opposing vertical flows in liquid-saturated porous media  

Energy Technology Data Exchange (ETDEWEB)

Mixed-convection phenomena can occur within liquid-dominated geothermal reservoirs due to interactions of injected flows, or ground-water flows, with the buoyancy-induced fluid motion. This problem was studied experimentally and numerically for the case of opposing flows about a vertical heat source in a liquid-saturated porous medium. The ratio of the Rayleigh number (Ra) to the Peclet number (Pe) was identified as the nondimensional parameter which characterizes the relative influence of buoyancy-driven to pressure-gradient-driven fluid motion. The transition from mixed to forced convection was numerically determined to be (Ra/Pe) approx. = -0.5, where the minus sign denotes superimposed downflow. Agreement between measured and predicted thermal-field results showed that the finite-element code of Gartling and Hickox (1982 a,b) can be used to model low-temperature (single-phase) geothermal reservoirs throughout the natural, mixed, and forced ...

1985-01-01

386

Toward a 2D SPH Multiphysic Code with Solid-Solid & Fluid Interactions for Industrial Related Problems  

CERN Document Server

In the present study, applications of the SPH method to industrial related issues are considered by starting from an existing open source 2D SPH code, namely the SPHYSICS code, which offers an effective ground for numerical developments, which are performed in order to bring an answer to industrial problems, such as simulations of solid/fluid coupling in a free surface flow context. The purpose of the present paper is therefore to expose the numerical developments which yield an enhanced version (referred to as "SPHYSIC2") of the initial code. Firstly, the different features added to obtain the operational code needed for engineering applications are described, and so are the problems raised on this way, offering a kind of review of SPH methods for engineers. Secondly, the validation of the proposed code is partially presented with two well known but difficult test cases, namely the classical "dam break" and "wedge entry" problems. Thirdly, principles of a method ...

2010-01-01

387

Time-Dependent 2D Modeling of Magnetron Plasma Torch in Turbulent Flow  

International Nuclear Information System (INIS)

A theoretical model is presented to describe the electromagnetic, heat transfer and fluid flow phenomena within a magnetron plasma torch and in the resultant plume, by using a commercial computational fluid dynamics (CFD) code FLUENT. Specific calculations are presented for a pure argon system (i.e., an argon plasma discharging into an argon environment), operated in a turbulent mode. An important finding of this work is that the external axial magnetic field (AMF) may have a significant effect on the behavior of arc plasma and thus affects the resulting plume. The AMF impels the plasma to retract axially and expand radially. As a result, the plasma intensity distribution on the cross section of torch seems to be more uniform. Numerical results also show that with AMF, the highest plasma temperature decreases and the anode arc root moves upstream significantly, while the current density distribution at the anode is more concentrated with a ...

2008-06-01

388

The chemistry of hydrothermal mounds near the Galapagos Rift  

Science.gov (United States)

Samples dredged from the sediment mounds have a unique chemistry and mineralogy which reveals details of the hydrothermal processes that produce these deposits. The mounds form primarily by deposition of Fe, Mn and Si from hydrothermal fluids which circulate through the basalt crust and the overlying sediments. The Mn, Fe and Si are strongly fractionated in the process; the Fe and Si precipitate within the mounds under slightly reducing conditions as nontronite, while the Mn is deposited as Mn oxyhydroxides at the seawater-sediment interface. The nontronite is exceptionally well crystallized, and contains less than 200 ppm Al. The Mn minerals, todorokite and birnessite, also have exceptional crystallinity and the distribution of trace elements Cu, Ni, Zn, Co, Ca and Ba in these phases agrees with predictions made on the basis of models of their crystal structure. The environment of deposition which produces this suite of minerals - slow percolation of hydrothermal ...

1978-06-01

389

Testing program for development of a high pressure, multi-product, fluid swivel  

Energy Technology Data Exchange (ETDEWEB)

This paper defines a rigorous seal test program conducted to develop a functional and proven high-pressure, multi-product swivel suitable for use as a Floating Production Storage and Offloading (FPSO) unit for the transfer of liquids and gases at high pressures and high temperatures through a rotating system. The test program was accomplished with specially designed test equipment with computer monitoring of temperature, torque, fluid pressures, seal lip temperatures, number of cycles, and leakage. The three primary phases are: (A) Seal Laterial screening with a computer-automated Falex testing machine, plus physical testing of chemically exposed samples. (B) One-third scale testing of several seal system configurations using a hydraulic driven, computer controlled test machine. (C) Full scale testing of prototype swivel. This paper documents the procedures for selection and testing of both the seal materials and the seal configuration. The test results clearly ...

1985-01-01

390

Supercritical fluid extraction from dried banana peel (Musa spp., genomic group AAB): Extraction yield, mathematical modeling, economical analysis and phase equilibria  

British Library Electronic Table of Contents (United Kingdom)

Supercritical fluid extraction from dried banana peel (Musa spp., subgroup Prata, genomic group AAB, popularly known in Brazil as Enxerto) was studied. The aspects investigated were: overall extraction curve (OEC), mass transfer modeling of the yield curves, economical analysis of the process and phase equilibrium data for the pseudo-ternary system of banana peel extract, carbon dioxide and ethanol. The extraction operating conditions evaluated were: pressure ranging from 100bar to 300bar, temperature from 40 to 50^oC and constant solvent flow rate of 5.0gCO2/min. Experimental extraction data were correlated using three kinetic models based on mass transfer equations (logistic, diffusion and Esquivel models). Phase equilibrium measurements were performed using pressure from 64.9bar to 239....

2010-01-01

391

Spectrally condensed fluid turbulence and L-H transitions in plasma  

International Nuclear Information System (INIS)

Recent experimental and theoretical studies of two-dimensional (2D) turbulence reveal that spectrally condensed turbulence which is a system of coupled large-scale coherent flow and broadband turbulence, is similar to plasma turbulence near the L-H transition threshold. Large condensate vortices fed via the turbulent inverse energy cascade, can control both the level of the broadband turbulence by shear decorrelation, and the energy injected into turbulence at the forcing scale via sweeping of the forcing-scale vortices. The interaction between these ingredients of spectrally condensed fluid turbulence is in many aspects similar to the interactions in the zonal flow-GAMs-turbulence system in plasma. In this paper we overview recent results on condensed 2D turbulence and present evidence of interaction between its three components: condensate structures, turbulence and forcing-scale vortices. This is compared with the modifications in the spectra of plasma ...

2009-06-01

392

Specific heating power of fatty acid and phospholipid stabilized magnetic fluids in an alternating magnetic field  

Energy Technology Data Exchange (ETDEWEB)

Magnetic fluids (MFs) with a similar narrow size distribution of the iron oxide core were stabilized with lauric acid (MF 1), oleate (MF 2) or, after dialysis in the presence of liposomes, with phospholipid molecules (MF 3 and MF 4, respectively). The hydrodynamic sizes of the MF 1 and MF 3 were half those found for MF 2 and MF 4. The MFs were exposed to inductive heating in an alternating magnetic field at a frequency of 200 kHz and a maximum magnetic field strength of 3.8 kA m{sup -1}. Specific absorption rates (SAR) of 294 {+-} 42 (MF 1), 214 {+-} 16 (MF 2), 297 {+-} 13 (MF 3) and 213 {+-} 6 W g{sup -1} Fe (MF 4) were obtained. The data for MF 2 and MF 4 were identical to those found for the commercially available ferucarbotran. The biomedical relevance of the phospholipid-coated MFs is briefly discussed.

2008-05-21

393

Second law analysis of compressible flow through a diffuser subjected to constant heat flux at wall  

International Nuclear Information System (INIS)

Entropy generation is equivalent to destruction of available work (exergy). The useful energy is destroyed due to the intrinsic irreversibility associated within thermodynamic systems. Exergy analysis can be used as an effective basis for the development and improvement of systems design not only in the overall perspective but also in the individual component level. Second law analysis provides a useful tool to identify the irreversibility in any thermal system. This study presents the investigation of local and total entropy generation in compressible flow through a diffuser. Air is used as the fluid. Uniform heat flux boundary condition is applied at the wall. Two dimensional solution of velocity and temperature fields are obtained using the CFD code FLUENT. Distribution of entropy generation rate is investigated throughout the volume of the fluid as it flows through the diffuser. Regions of high entropy generation in the diffuser have been ...

2010-12-01

394

Research program: the investigation of heat transfer and fluid flow at low pressure  

International Nuclear Information System (INIS)

This paper gives an overview of a multiyear joint research program being conducted at the University of New Mexico (UNM) with support from Sandia National Laboratories and GA Technologies. This research focuses on heat removal and fluid dynamics in flow regimes characterized by low pressure and low Reynolds number. The program was motivated by a desire to characterize and analyze cooling in a broad class of TRIGA-type reactors under: (a) typical operating conditions, (b) anticipated, new operating regimes, and (c) postulated accident conditions. It has also provided experimental verification of analytical tools used in design analysis. The paper includes descriptions of the UNM thermal-hydraulics test facility and the experimental test sections. During the first two years experiments were conducted using single, electrically heated rod in water and air annuli. This configuration provides an observable and serviceable simulation of a fuel rod and its coolant ...

1986-04-07

395

Research on Dynamic Neutron Radiography in HANARO  

Energy Technology Data Exchange (ETDEWEB)

Neutron radiography is a non-destructive test method to examine a material by using the dependency of neutron attenuation on the nuclear characteristics of the atoms composing the object material. There are two categories of neutron radiography; static neutron radiography and dynamic neutron radiography. The static neutron radiography is a technique to observe a standing object by using a camera or a film cassette. The dynamic neutron radiography(DNR) is a technique to observe a moving object usually by using a camera. Depending on the camera frame rate, the dynamic neutron radiography is categorized into the real time neutron radiography(RTNR) and the high speed neutron radiography(HSNR). The frame rate for RTNR is 30 frames/s and that for HSNR is usually more that 500 frames/sec. Thus, RTNR is good for observing time-averaged phenomena and HSNR is good for observing instantaneous phenomena. DNR is a powerful tool for fluid visualization as well as the multi-phase ...

2005-07-01

396

Research on Dynamic Neutron Radiography in HANARO  

International Nuclear Information System (INIS)

Neutron radiography is a non-destructive test method to examine a material by using the dependency of neutron attenuation on the nuclear characteristics of the atoms composing the object material. There are two categories of neutron radiography; static neutron radiography and dynamic neutron radiography. The static neutron radiography is a technique to observe a standing object by using a camera or a film cassette. The dynamic neutron radiography(DNR) is a technique to observe a moving object usually by using a camera. Depending on the camera frame rate, the dynamic neutron radiography is categorized into the real time neutron radiography(RTNR) and the high speed neutron radiography(HSNR). The frame rate for RTNR is 30 frames/s and that for HSNR is usually more that 500 frames/sec. Thus, RTNR is good for observing time-averaged phenomena and HSNR is good for observing instantaneous phenomena. DNR is a powerful tool for fluid visualization as well as the multi-phase ...

2005-10-27

397

Research and development on probe inserting method into steam generator helically coiled tubes for in-service inspection  

International Nuclear Information System (INIS)

Helically coiled tubes of steam generators (SG) in FBR are boundaries between sodium and water/steam. Therefore, to assure the integrity of tubes, it is necessary to inspect the tubes nondestructively for in service or after a sodium-water reaction accident. In order to make it possible to conduct in-service inspection of SG tubes, we have studied on eddy current probes and probe inserting methods. As for the probe inserting method, IHI designed a fluid driving type which consists of a model probe and signal cable with float balls and driven by air pressure force. Presented in this paper is the authors' report, which describes the fluid driving type as an effective method to insert an eddy current probe into helically coiled tubes. The outline of the test results is as follows: 1. It was possible to insert the probe into 65 meter length helically coiled tubes. 2. We could detected, as anticipated, a defect (outer circumferential wall thinning ...

1979-01-01

398

Pump application desk book  

Energy Technology Data Exchange (ETDEWEB)

The large number of forms and types of pump equipment in common use have different purposes and varying application requirements. This text has been prepared to bring together necessary information for those who are required to select and apply pumps in systems for all kinds of fluids and purposes. It is not a design manual. It limits the discussion of design to those factors which are necessary for an understanding of pump operation. The book contains not only descriptive information of many types of designs, but also the effect of design variation on use, economy, and reliability. Systems, an integral part of application, are discussed, so that the user of such equipment may properly select and install machines to reliably and economically satisfy his requirements. Reading of appropriate sections of the text will indicate possible problems to be avoided, and economics to be gained. The engineering design of pumps is a science; their proper application is an art. ...

1990-01-01

399

Process model for carbothermic production of silicon metal  

Energy Technology Data Exchange (ETDEWEB)

This thesis discusses an advanced dynamical two-dimensional cylinder symmetric model for the high temperature part of the carbothermic silicon metal process, and its computer encoding. The situation close to that which is believed to exist around one of three electrodes in full-scale industrial furnaces is modelled. This area comprises a gas filled cavity surrounding the lower tip of the electrode, the metal pool underneath and the lower parts of the materials above. The most important phenomena included are: Heterogeneous chemical reactions taking place in the high-temperature zone (above 1860 {sup o}C), Evaporation and condensation of silicon, Transport of materials by dripping, Turbulent or laminar fluid flow, DC electric arcs, Heat transport by convection, conduction and radiation. The results from the calculations, such as production rates, gas- and temperature distributions, furnace- and particle geometries, fluid flow fields etc, are ...

1995-09-12

400

Preliminary studies of coolant by-pass flows in a prismatic very high temperature reactor using computational fluid dynamics  

Energy Technology Data Exchange (ETDEWEB)

Three dimensional computational fluid dynamic (CFD) calculations of a typical prismatic very high temperature gas-cooled reactor (VHTR) were conducted to investigate the influence of gap geometry on flow and temperature distributions in the reactor core using commercial CFD code FLUENT. Parametric calculations changing the gap width in a whole core length model of fuel and reflector columns were performed. The simulations show the effects of core by-pass flows in the heated core region by comparing results for several gap widths including zero gap width. The calculation results underline the importance of considering inter-column gap width for the evaluation of maximum fuel temperatures and temperature gradients in fuel blocks. In addition, it is shown that temperatures of core outlet flow from gaps and channels are strongly affected by the gap width of by-pass flow in the reactor core.

2009-09-01

401

Percutaneous drainage of abdominal abcess  

Energy Technology Data Exchange (ETDEWEB)

The mortality in undrained abdominal abscesses is high with a mortality rate ranging between 45 and 100%. The outcome in abdominal abscesses, however, has improved due to advances in image guided percutaneous interventional techniques. The main indications for the catheter drainage include treatment or palliation of sepsis associated with an infected fluid collection, and alleviation of the symptoms that may be caused by fluid collections by virtue of their size, like pancreatic pseudocele or lymphocele. The single liver abscesses may be drained with ultrasound guidance only, whereas the multiple abscesses usually require computed tomography (CT) guidance and placement of multiple catheters. The pancreatic abscesses are generally drained routinely and urgently. Non-infected pancreatic pseudocysts may be simply observed unless they are symptomatic or cause problems such as pain or obstruction of the biliary or the gastrointestinal tract. ...

2002-09-01

402

Organic-inorganic mixtures for solar energy storage systems  

Energy Technology Data Exchange (ETDEWEB)

Mixtures of organic-inorganic substances are studied for their performance as energy storage media. Use is made of the fact that organic substances give higher amounts of energy but within a wide range of temperature on the one side and the fact that inorganic substances give lower amounts of energy at constant temperature on the other side. Mixtures of both types of substances, in different ratios, are investigated for the object of determining that optimum composition which stores a higher amount of energy and, meanwhile, releases it at a constant temperature or within a narrow range of temperature. The mixtures used are composed of Glauber`s salt (Na{sub 2}SO{sub 4}.10H{sub 2}O) and stearic acid in different proportions. The effect of cooling fluid flow rate and ambient temperature as well as the effect of addition of a nucleating agent is studied. The results showed that the highest amount of energy stored could be obtained from a mixture containing 40% stearic ...

1995-10-01

403

Optoelectronic multipoint liquid level sensor for light petrochemical products  

Science.gov (United States)

In this article we describe an optoelectronic sensor for assessing the level of light petrochemical products in technological tanks at the oil refineries. This sensor employs the multi-element vertical array of discrete micro- optical refractometric transducers. The transducers are made of silica glass and have the conical shape. In the air, each transducer operates as a tiny retro-reflector that optically couple together two multimode optical fibers. The optical coupling in the transducer is due to the internal reflection at the conical surface. The amount of the coupling depends on the refractive index of the surrounding media. In a fluid, the total internal reflection vanishes and the coupling becomes negligibly small. The number of immersed transducers is a measure of the fluid level in the reservoir. Because of the significance of the transducer transmission function, it is evaluated in detail under various combinations of the geometrical ...

2000-06-01

404

Onset of convection in a couple-stress fluid-saturated porous medium: effects of non-uniform temperature gradients  

Energy Technology Data Exchange (ETDEWEB)

Onset of convection in a layer of couple-stress fluid-saturated porous medium is investigated for different types of basic temperature gradients. The boundaries are considered to be adiabatically insulated to temperature perturbations. The eigenvalue equations of the perturbed state obtained from the normal mode analysis are solved analytically using a regular perturbation technique with wave number as a perturbation parameter and also numerically using the Galerkin technique. The critical stability parameters obtained from these two techniques are in excellent agreement and an increase in the value of couple-stress parameter is found to delay the onset of convection. The results also indicate that the piecewise linear temperature profile hastens the onset of convection when compared to linear, parabolic, and inverted parabolic temperature profiles. In addition, the influence of thermal depth on the critical conditions is assessed in the case of piecewise linear ...

2010-08-15

405

Membrane compressor for leakfree compression of gaseous fluids; Membranverdichter fuer das leckfreie Verdichten gasfoermiger Fluide  

Energy Technology Data Exchange (ETDEWEB)

Leakfree compression of gaseous liquids prevents impurities resulting from entry of lubricants and abrasive particles and is therefore an important requirement on modern compressors. Another requirement voiced increasingly often is the reduction or even prevention of problematic off-gases and contaminated residues of libricating oils. Further, compressors should have high corrosion resistance, low noise, a long service life and high reliability. Membrane compressors are largely able to meet these requirements. The article describes the technical concept and applications of membrane compressors. (orig.) [Deutsch] Umweltschutz und steigende Forderungen der Industrie an die Reinheit technischer Gase verlangen Kompressoren, die weitgehend leckagefrei verdichten und keine Verunreinigungen des Gases durch Schmierstoffe und Abrieb hervorrufen. Immer haeufiger wird in diesem Zusammenhang die Reduzierung oder sogar die Vermeidung von schwer zu entsorgenden Abgasen und kontaminierten ...

1996-09-01

406

Isolation condenser passive cooling of a nuclear reactor containment  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a nuclear system comprising a containment airspace in which a nuclear reactor pressure vessel is disposed there being a reactor core within the pressure vessel. It comprises a heat exchanger elevated a distance above the pressure vessel; a pool of water surrounding the heat exchanger; means for venting the pool of water to an environment outside the containment; a heat exchanger entry conduit within the containment, the entry conduit having an open lower end communicating with the containment space, and an upper end connected to the heat exchanger, water-containing heated fluid present in the containment airspace incident a pressure vessel loss of coolant event entering and flowing through the entry conduit into the heat exchanger for cooling the fluid to convert water vapor therein to a condensate and separate non-condensable gasses therefrom; a gravity driven cooling water pond-containing space, the gravity cooling water ...

1991-10-22

407

Interface heat transfer of horizontal co-current liquid-liquid stratified flow. II - Entrance region  

Science.gov (United States)

Flow structures and heat transfer at the liquid-liquid interface are investigated experimentally and analytically in the entrance region of a liquid metal-water stratified flow in a horizontal rectangular channel. The two-equation model and the mixing length mode, including a damping turbulent region near the interface, are used to obtain analytical results for pressure drop, position of the interface, and heat transmission coefficients across the interface. Analytical results are compared with experimental results. Conclusions are presented and include the following: (1) vertical position of the interface increases or decreases along the stream according to the fluid flow rate of both fluids, and then approaches a constant value in the fully developed region; (2) pressure drop increases along the stream from the minimum value at the inlet; and (3) heat transmission coefficients across the interface decrease in the entrance region to a minimum ...

1981-06-01

408

Integrated model of the shallow and deep hydrothermal systems in the East Mesa area, Imperial Valley, California  

Energy Technology Data Exchange (ETDEWEB)

Geological, geophysical, thermal, petrophysical and hydrological data available for the East Mesa hydrothermal system that are pertinent to the construction of a computer model of the natural flow of heat and fluid mass within the system are assembled and correlated. A conceptual model of the full system is developed and a subregion selected for quantitative modeling. By invoking the Boussinesq approximation, valid for describing the natural flow of heat and mass in a liquid hydrothermal system, it is found practical to carry computer simulations far enough in time to ensure that steady-state conditions are obtained. Initial calculations for an axisymmetric model approximating the system demonstrate that the vertical formation permeability of the deep East Mesa system must be very low (k/sub v/ approx. 0.25 to 0.5 md). Since subsurface temperature and surface heat flow data exhibit major deviations from the axisymmetric approximation, exploratory three-dimensional ...

1982-01-01

409

Incorporation of Reaction Kinetics into a Multiphase, Hydrodynamic Model of a Fischer Tropsch Slurry Bubble Column Reactor  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the development of a computational multiphase fluid dynamics (CMFD) model of the Fischer Tropsch (FT) process in a Slurry Bubble Column Reactor (SBCR). The CMFD model is fundamentally based which allows it to be applied to different industrial processes and reactor geometries. The NPHASE CMFD solver [1] is used as the robust computational platform. Results from the CMFD model include gas distribution, species concentration profiles, and local temperatures within the SBCR. This type of model can provide valuable information for process design, operations and troubleshooting of FT plants. An ensemble-averaged, turbulent, multi-fluid solution algorithm for the multiphase, reacting flow with heat transfer was employed. Mechanistic models applicable to churn turbulent flow have been developed to provide a fundamentally based closure set for the equations. In this four-field model formulation, two of the fields are used to track ...

2008-11-01

410

Hemispheres-in-cell geometry to predict colloid deposition in porous media.  

Science.gov (United States)

A "hemispheres-in-cell" geometry is provided for prediction of colloid retention during transport in porous media. This new geometry preserves the utilities provided in the Happel sphere-in-cell geometry; namely, the ability to predict deposition for a range of porosities, and representation of the influence of neighboring collectors on the fluid flow field. The new geometry, which includes grain to grain contact, is justified by the eventual goal of predicting colloid deposition in the presence of energy barriers, which has been shown in previous literature to involve deposition within grain to grain contacts for colloid:collector ratios greater than approximately 0.005. In order to serve as a platform for predicting deposition in the presence of energy barriers, the model must be shown capable of quantitatively predicting deposition in the absence of energy barriers, which is a requirement that was not met by previous grain to grain contact geometries. This paper ...

2009-11-15

411

Further development of excentric screw pumps for reduction of fluid levels in gas wells; Weiterentwicklung von Exzenterschneckenpumpen zur Fluessigkeitsspiegelabsenkung in Gasbohrungen  

Energy Technology Data Exchange (ETDEWEB)

Beside sucker-rod-type pumps and submersible centrifugal pumps, excentric screw pumps (so-called progressing cavity pumps) belong to standard conveyors in the production of crude oil. The authors of the contribution under consideration present the further development of excentric screw pumps with respect to the reduction of fluid levels in gas wells. This further development is based on a co-operation between the operator (Rohoel Aufsuchungs AG (Gampern, Austria)), the pump supplier (NETZSCH Oilfield Products GmbH (Selb, Federal Republic of Germany)) and the Institute for Process Technologies and Machinery at the University of Erlangen-Nuernberg (Federal Republic of Germany). The authors report on first attempts with the excentric screw pump at Weizberg (Federal Republic of Germany), material investigations at the University of Erlangen-Nuernberg, optimization of pump components and pump systems as well as on the optimization of the entire drainage process. ...

2008-10-23

412

Fundamental investigation of duct/ESP phenomena  

Energy Technology Data Exchange (ETDEWEB)

This report describes in detail the First Generation Duct Injection Model developed for the analysis of the fundamental processes of flue gas desulfurization by sorbent injection. The model is a two- and three-dimensional, multiphase reacting flow analyzer using computational fluid dynamics methods. The gaseous phase is solved in an Eulerian frame while the droplets or particles are tracked in a Lagrangian frame. The model has an associated preprocessor which allow easy problem set up by the use without in-depth knowledge of computational fluid dynamics. The aerodynamics of the First Generation Duct Injection Model have been successfully validated with a number of test cases for which experimental data are available. Data from the Meredosia pilot plant humidification tests have been used to validate the gas and droplet dynamics of the model with good agreement. Comparison of SO{sub 2} removal results using the present model (with one injector) ...

1990-12-01

413

Freeze protection valve for solar heaters  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a solar heater freeze protection valve apparatus comprising in combination: a valve housing; a remote sensor operatively connected to the valve housing from a remote position, the remote sensor including a bulb containing a liquid adapted to compress and expand with the temperature adjacent the bulb; a piston located in the valve body and slidable responsive to expansion and contraction of the liquid in the remote sensor; a first valve element located in the valve housing and attached to the valve piston for movement; a second valve element located in the valve housing and attached to the housing; a first valve seat in the second valve element forming an opening; a second valve seat positioned in a water passageway to allow the flow of fluid when the second valve element is in an open position and to cut off the flow of fluid when the second valve element is in a closed position. Liquid in a solar heater flows at ...

1987-07-21

414

Free and forced convective cooling of pipe-type electric cables. Volume 2: electrohycrodynamic pumping. Final report  

Energy Technology Data Exchange (ETDEWEB)

A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one, reported in Volume 1, dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of entrance and exit chambers for the cooling oil. The second major ...

1981-05-01

415

Free and forced convective cooling of pipe-type electric cables. Volume 1: forced cooling of cables. Final report  

Energy Technology Data Exchange (ETDEWEB)

A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one reported in this volume dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of entrance and exit chambers for the cooling oil. The second major ...

1981-05-01

416

Fluid pressure arrival time tomography: Estimation and assessment in the presence of inequality constraints, with an application to a producing gas field at Krechba, Algeria  

Energy Technology Data Exchange (ETDEWEB)

Deformation in the overburden proves useful in deducing spatial and temporal changes in the volume of a producing reservoir. Based upon these changes we estimate diffusive travel times associated with the transient flow due to production, and then, as the solution of a linear inverse problem, the effective permeability of the reservoir. An advantage an approach based upon travel times, as opposed to one based upon the amplitude of surface deformation, is that it is much less sensitive to the exact geomechanical properties of the reservoir and overburden. Inequalities constrain the inversion, under the assumption that the fluid production only results in pore volume decreases within the reservoir. We apply the formulation to satellite-based estimates of deformation in the material overlying a thin gas production zone at the Krechba field in Algeria. The peak displacement after three years of gas production is approximately 0.5 cm, overlying the eastern margin of the ...

2010-04-01

417

Fluid dynamics of jet-forming elements of contact devices with directional gas stream injection  

International Nuclear Information System (INIS)

One way to intensify heat and mass transfer processes in column-type equipment is through use of contact devices with directional gas phase injection into a liquid. Making the perforations at an angle to the tray plane permits a rise in the permissible gas velocity in the column, since inertial force adds to gravity during separation. Different arrangements of the jet-forming elements relative to one another and to partitions and baffle-type contacts installed on the trays can improve phase contact conditions and intensify heat and mass transfer. Design of jet-type trays for a specific purpose requires that the influence of jet-forming, element design parameters on at least the fluid dynamic situation on the tray be known. In this work, the authors evaluate the influence of tab bend-up angle on jet tray working characteristics. These investigations demonstrate that the jet inclination angle (the angle of maximum gas velocity in the jet) exceeds the tab bend-up ...

418

Fluid dynamics analysis of a Ranque-Hilsch vortex tube  

International Nuclear Information System (INIS)

Fluid dynamic analysis of a commercial, counter-flow Ranque-Hilsch Vortex Tube (Rh vt), Ex air 25 s cfm, has been performed in this work both experimentally and numerically; in particular Rh vt cooling power and temperature separation performances have been tested in both direct cooling employment (jet impingement) and indirect cooling employment (supplying cold plates). Experimental techniques, used in this work, revealed several difficulties to produce detailed information about velocity and temperature fields inside the tube and at both the exits. Hence numerical simulation of the flow inside the tube has been conducted using the commercial Cfd code Fluent 6.3.26. Compressible, turbulent, high swirling flow inside Rh vt has been simulated by using both Rans and Les approaches. In particular several turbulence closures have been used in the Rans simulations and results have been compared with Les ones. Large Eddy Simulations have been performed using Smagorinsky ...

2008-05-01

419

Experiments on liquid immersion natural convection cooling of leadless chip carriers mounted on ceramic substrate  

Science.gov (United States)

An experimental investigation of natural convection heat transfer from a commercially available semiconductor device package is presented. The package was centrally mounted on a ceramic substrate. The package-substrate assembly formed one surface of a dielectric-filled cubical enclosure of aspect ratio one. The top surface of the enclosure was maintained at prescribed temperature. Surface temperature measurements were made at various locations on the substrate, the package lid, as well as the chip center. These measurements are reported for three dielectric fluids and three enclosures top surface temperatures, both with the substrate oriented horizontally as well as vertically. The results indicate that the maximum input power without exceeding a chip junction temperature of 80 C is 2.58 watts with FC-75 as the cooling fluid and the upper boundary maintained at 15 C. This is significantly larger than the maximum of 1.21 watts allowable with the ...

1989-09-01

420

Experimental investigation of mixed convection heat transfer from longitudinal fins in a horizontal rectangular channel: In natural convection dominated flow regimes  

British Library Electronic Table of Contents (United Kingdom)

Mixed convection heat transfer from longitudinal fins inside a horizontal channel has been investigated in the natural convection dominated region for a wide range of Rayleigh numbers and different fin heights and spacings. An experimental parametric study was made to investigate effects of fin spacing, fin height and magnitude of heat flux on mixed convection heat transfer from rectangular fin arrays heated from below in a horizontal channel. The optimum fin spacing to obtain maximum heat transfer has also been investigated. During the experiments constant heat flux boundary condition was realized and air was used as the working fluid. The velocity of fluid entering channel was kept nearly constant (0.02win0.025m/s) using a flow rate control valve so that Reynolds number was always about ...

2009-01-01

421

Enzyme-linked immunosorbent assays for alpha-synuclein with species and multimeric state specificities.  

Science.gov (United States)

Abnormal intracellular deposition of aggregated ?-synuclein is the characteristic feature of a number of neurological disorders, including Parkinson's disease (PD). Although ?-synuclein is typically known as a cytosolic protein, a small amount is secreted by exocytosis in both monomeric and aggregated forms. The extracellular forms of ?-synuclein in human body fluids, such as cerebrospinal fluid (CSF) and blood plasma, might be a diagnostic target for PD and related diseases. Here, we characterized a new set of monoclonal antibodies against ?-synuclein, and using different combinations of antibodies, we established ELISA systems to specifically detect human ?-synuclein, mouse and human ?-synuclein together, and multimeric forms of ?-synuclein in biological samples. By employing the Tyramide signal amplification method, the sensitivity of the assay was significantly improved to detect a concentration as low as ?12.5 pg/ml. These assays might be ...

2011-05-31

422

Environmental monitoring at Kahe Point, Oahu, Hawaii for OTEC pilot-plant development  

Energy Technology Data Exchange (ETDEWEB)

Two 40 MWe Ocean Thermal Energy Conversion (OTEC) Pilot Plant programs are in the initial phase of development near Kahe Point, Oahu, Hawaii. The two options being examined are: (1) a shelf-seated artificial island, connected via a causeway to Oahu, using stainless steel heat exchangers, with the thermal resource enhanced by effluent from a near-by power plant, ammonia working fluid and biocide (chlorine) cleaning; and (2) a shelf mount tower 1 mile off shore using submerged aluminum heat exchangers, R-22 working fluid, and slurry cleaning with biocide (chlorine) backup. Environmental Technical Requirements are described including: siting criteria; environmental design, and operational criteria; thermal resource evaluation and variability; physical, chemical, and biological data requirements; and regulatory requirements. Due to siting, design, and operational differences the proposed two pilot plant options have individual environmental ...

1982-08-01

423

Engineering design of cryocondensation pumps for the DIII-D Radiative Divertor Program  

Energy Technology Data Exchange (ETDEWEB)

A new double-null, slotted divertor configuration will be installed for the DIII-D Radiative Divertor Program at General Atomics in late 1996. Four cryocondensation pumps, three new and one existing, will be part of this new divertor. The purpose of the pumps is to provide plasma density control and to limit the impurities entering the plasma core by providing pumping at each divertor strike point. The three new pumps are based on the design of the existing pump, installed in 1992 as part of the Advanced Divertor Program. The pump continues to operate successfully. The new pumps require geometry modifications to the original design. Therefore, extensive modal and dynamic analyses were performed to determine the behavior of these pumps and their helium and nitrogen feed lines during disruption events. Thermal and fluid analyses were also performed to characterize the helium two-phase flow regime in the pumps and their feedlines. A flow testing program was completed ...

1995-12-31

424

Engineering design of cryocondensation pumps for the DIII-D Radiative Divertor Program  

Energy Technology Data Exchange (ETDEWEB)

A new double-null, slotted divertor configuration will be installed for the DIII-D Radiative Divertor Program at General Atomics in late 1996. Four cryocondensation pumps, three new and one existing, will be part of this new divertor. The purpose of the pumps is to provide plasma density control and to limit the impurities entering the plasma core by providing pumping at each divertor strike point. The three new pumps are based on the design of the existing pump, installed in 1992 as part of the Advanced Divertor Program. The new pumps require geometry modifications to the original design. Therefore, extensive modal and dynamic analyses were performed to determine the behavior of these pumps and their helium and nitrogen feed lines during disruption events. Thermal and fluid analyses were also performed to characterize the helium two-phase flow regime in the pumps and their feedlines. A flow testing program was completed to test the change in geometry of the pump ...

1995-10-01

425

Engineering design of cryocondensation pumps for the DIII-D Radiative Divertor Program  

International Nuclear Information System (INIS)

A new double-null, slotted divertor configuration will be installed for the DIII-D Radiative Divertor Program at General Atomics in late 1996. Four cryocondensation pumps, three new and one existing, will be part of this new divertor. The purpose of the pumps is to provide plasma density control and to limit the impurities entering the plasma core by providing pumping at each divertor strike point. The three new pumps are based on the design of the existing pump, installed in 1992 as part of the Advanced Divertor Program. The pump continues to operate successfully. The new pumps require geometry modifications to the original design. Therefore, extensive modal and dynamic analyses were performed to determine the behavior of these pumps and their helium and nitrogen feed lines during disruption events. Thermal and fluid analyses were also performed to characterize the helium two-phase flow regime in the pumps and their feedlines. A flow testing program was completed ...

1995-10-01

426

Effect on heat-transfer augmentation by channel width in a sinusoidal wave channel  

Energy Technology Data Exchange (ETDEWEB)

In the development of high performance heat transfer surface on a compact heat exchanger, it was clarified that how reattachment point heat transfer and fluid flow are affected by channel width, at the same time, an evaluation of heat transfer performance and an investigation of optimum channel width were carried out. The channel system used in the experiment is as follows; (1) blow-off type with rectangular section channel, (2) span length of 200 mm, (3) wave length (pitch) of 80 mm, and (4) channel length of 12.5 wave length. The channel Reynolds number was set at about 10/sup 4/ which is relatively higher than the current studies. The results of the experiment were summarized as follows. (1) The channel width H has relevance to the phase difference between the fluid flow in cone portion of main stream and wave shape, the flow patterns are divided roughly into three types. These boundaries exist at P/H 3.0 and 1.5 (P: pitch, H: width). (2) ...

1988-06-25

427

Double-diffusive convection in a Darcy porous medium saturated with a couple-stress fluid  

Energy Technology Data Exchange (ETDEWEB)

The onset of double-diffusive convection in a couple-stress fluid-saturated horizontal porous layer is studied using linear and weak nonlinear stability analyses. The modified Darcy equation that includes the time derivative term and the inertia term is used to model the momentum equation. The expressions for stationary, oscillatory and finite-amplitude Rayleigh number are obtained as a function of the governing parameters. The effect of couple-stress parameter, solute Rayleigh number, Vadasz number and diffusivity ratio on stationary, oscillatory and finite-amplitude convection is shown graphically. It is found that the couple-stress parameter and the solute Rayleigh number have a stabilizing effect on stationary, oscillatory and finite-amplitude convection. The diffusivity ratio has a destabilizing effect in the case of stationary and finite-amplitude modes, with a dual effect in the case of oscillatory convection. The Vadasz number advances the onset of ...

2010-06-15

428

Double-diffusive convection in a Darcy porous medium saturated with a couple-stress fluid  

International Nuclear Information System (INIS)

The onset of double-diffusive convection in a couple-stress fluid-saturated horizontal porous layer is studied using linear and weak nonlinear stability analyses. The modified Darcy equation that includes the time derivative term and the inertia term is used to model the momentum equation. The expressions for stationary, oscillatory and finite-amplitude Rayleigh number are obtained as a function of the governing parameters. The effect of couple-stress parameter, solute Rayleigh number, Vadasz number and diffusivity ratio on stationary, oscillatory and finite-amplitude convection is shown graphically. It is found that the couple-stress parameter and the solute Rayleigh number have a stabilizing effect on stationary, oscillatory and finite-amplitude convection. The diffusivity ratio has a destabilizing effect in the case of stationary and finite-amplitude modes, with a dual effect in the case of oscillatory convection. The Vadasz number advances the onset of ...

2010-06-01

429

Diverter system test tool and method  

Energy Technology Data Exchange (ETDEWEB)

A method is described for testing a diverter system on an offshore drilling rig of a type having a marine riser assembly extending to a subsea well, the diverter system having a packer element and at least one port located below the packer element for the passage of drilling fluid flowing upward from the marine riser assembly during drilling. The method consists of connecting a tubular member to the upper end of a packer having an elastomeric expansive seal element; placing the packer in an upper portion of the marine riser assembly below the diverter system and expanding the seal element against the interior of the upper portion; closing the packer element of the diverter system around the tubular member; and finally applying fluid pressure in the space between the packer element of the diverter system and the seal element of the packer to determine if any leakage in the diverter system exists. The patent also describes an offshore drilling ...

1989-04-04

430

Development and Application of Subchannel Analysis Code Technology for Advanced Reactor Systems  

Energy Technology Data Exchange (ETDEWEB)

A study has been performed for the development and assessment of a subchannel analysis code which is purposed to be used for the analysis of advanced reactor conditions with various configurations of reactor core and several kinds of reactor coolant fluids. The subchannel analysis code was developed on the basis of MATRA code which is being developed at KAERI. A GUI (Graphic User Interface) system was adopted in order to reduce input error and to enhance user convenience. The subchannel code was complemented in the property calculation modules by including various fluids such as heavy liquid metal, gas, refrigerant,and supercritical water. The subchannel code was applied to calculate the local thermal hydraulic conditions inside the non-square test bundles which was employed for the analysis of CHF. The applicability of the subchannel code was evaluated for a high temperature gas cooled reactor condition and supercritical pressure conditions ...

2006-01-15

431

Determination of impurities in sialon by ICP-AES  

International Nuclear Information System (INIS)

Impurities (Ca, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Ti, Y, Zn and Zr) in sialon powder were determined by the following procedure: A sample (0.5 g) was heated with a mixture of hydrofluoric acid (3 ml) and nitric acid (1 ml) in a Teflon pressure vessel at 170degC for 16 h. The contents of the vessel were transferred into a platinum crucible containing phosphoric acid (4 ml) and heated on a hot plate until the opaque appearance of the content changed to a clear-syrupy fluid. The fluid was diluted to 100 ml with water and used for ICP-AES analysis of all impurity elements except K, which was determined by AAS. It was necessary to match closely the matrix concentrations (H_3PO_4, Al and/or Y) of the standard solutions with those of sialon sample solutions for the determination of impurities because of interferences of the matrix components. This method was successfully applied to the determination of impurities in commercial sialon samples. (author).

432

Determination of Inter-Phase Line Tension in Langmuir Films  

CERN Document Server

A Langmuir film is a molecularly thin film on the surface of a fluid; we study the evolution of a Langmuir film with two co-existing fluid phases driven by an inter-phase line tension and damped by the viscous drag of the underlying subfluid. Experimentally, we study an 8CB Langmuir film via digitally-imaged Brewster Angle Microscopy (BAM) in a four-roll mill setup which applies a transient strain and images the response. When a compact domain is stretched by the imposed strain, it first assumes a bola shape with two tear-drop shaped reservoirs connected by a thin tether which then slowly relaxes to a circular domain which minimizes the interfacial energy of the system. We process the digital images of the experiment to extract the domain shapes. We then use one of these shapes as an initial condition for the numerical solution of a boundary-integral model of the underlying hydrodynamics and compare the subsequent images of the experiment to ...

2007-01-01

433

Design and analysis of a dust extraction system  

Energy Technology Data Exchange (ETDEWEB)

A dust extraction system removes the contaminated air at source by means of a hood. The extraction system for dust is essentially a ducted air system that prevents excessive employee exposure to dust in the working zone. The four major mechanisms that remove the contaminants in an extraction system are: - capture of contaminants by hoods - transport of contaminated air in duct network - separation of dust in the collector - exhaust of clean air through stack. The current methods of design are based on empirical relations, multi-variable tables, graphs and nomographs that have been derived from the principle of fluid mechanics and particle dynamics. However, the empirical formulae, tables and graphs are used in different geographical locations of the world having different environmental conditions and geo-characteristics of dust particles. Therefore, it is required to establish a rational design method that will be based on analysis of each sub-system to achieve an ...

2006-07-01

434

Deposition and diagenesis of a cratonic Silurian platform reef, Pipe Creek Jr. , Indiana  

Energy Technology Data Exchange (ETDEWEB)

Petrographic and geochemical characteristics of the Pipe Creek Jr. paragenesis record the stratigraphic and burial evolution of the cratonic Silurian platform of Indiana during Late Silurian to Pennsylvanian. A variety of several diagenetic fluids acting over geological time affected the reef. The paragenetic sequence is as follows: (1) precipitation of turbid, fibrous, blotchy cathodoluminescent (CL) cement; (2) dolomitization of mud-rich facies; (3) precipitation of clear, zoned CL equant calcite cements; (4) fracturing and karst formation, partially filled by geopetal silt and sandstone; (5) precipitation of clear, dull CL, ferroan to nonferroan equant calcite cement, ferroan dolomite overgrowth and equant dolomite cement in moldic porosity, caves and fractures; (6) microdissolution and hydrocarbon emplacement; and (7) stylolitization. The New Albany Shale was both the hydrocarbon source and top seal to the fossil Pipe Creek Jr. oil field with original oil in ...

1988-02-01

435

Crystallization fouling of calcium sulfate dihydrate on heat-transfer surfaces  

Energy Technology Data Exchange (ETDEWEB)

The present paper deals with the fouling process of calcium sulfate dehydrate on heat-transfer surfaces. The crystallization of calcium sulfate showed typical asymptotic fouling curves, the asymptotic value of which was greatly influenced by the surface temperature and fluid velocity. The fouling mechanism was discussed with a generalized fouling model and proved to be surface process controlled, where the activation energy was 6.2 {times} 10{sup 4} J/mol. The availability of mechanical cleaning against the formed scale was quantitatively evaluated by applying the particle abrasion method. The removal test verified that the removing rate per unit particle concentration decreased in an inverse proportion to the overall particle load, to the power of 0.8, and that it was affected by the fluid velocity. The observed final residual fouling resistance decreased asymptotically with an increase in particle concentration. The suitable concentration of ...

1996-02-01

436

Coriolis effect on thermal convection in a couple-stress fluid-saturated rotating rigid porous layer  

Energy Technology Data Exchange (ETDEWEB)

Both linear and weakly nonlinear stability analyses are performed to study thermal convection in a rotating couple-stress fluid-saturated rigid porous layer. In the case of linear stability analysis, conditions for the occurrence of possible bifurcations are obtained. It is shown that Hopf bifurcation is possible due to Coriolis force, and it occurs at a lower value of the Rayleigh number at which the simple bifurcation occurs. In contrast to the nonrotating case, it is found that the couple-stress parameter plays a dual role in deciding the stability characteristics of the system, depending on the strength of rotation. Nonlinear stability analysis is carried out by constructing a set of coupled nonlinear ordinary differential equations using truncated representation of Fourier series. Sub-critical finite amplitude steady motions occur depending on the choice of physical parameters but at higher rotation rates oscillatory convection is found to be the preferred ...

2011-04-15

437

Computational fluid dynamics study of the effects of the re-entrant lip shape and toroidal radii of piston bowl on a high-speed direct-injection diesel engine's performance and emissions  

Energy Technology Data Exchange (ETDEWEB)

The piston bowl design is one of the most important factors that affect the air-fuel mixing and the subsequent combustion and pollutant formation processes in a direct-injection diesel engine. The bowl geometry and dimensions, such as the pip region, bowl lip area, and toroidal radius, are all known to have an effect on the in-cylinder mixing and combustion process. In order to understand better the effect of re-entrant geometry, three piston bowls with different toroidal radii and lip shapes were investigated using computational fluid dynamics engine modelling. KIVA3V with improved submodels was used to model the in-cylinder flows and combustion process, and it was validated on a high-speed direct-injection engine with a second-generation common-rail fuel injection system. The engine's performance, in-cylinder flow, and combustion, and emission characteristics were analysed at maximum power and maximum torque conditions and at part-load operating ...

2005-08-15

438

Chemical Looping Combustion System-Fuel Reactor Modeling  

Science.gov (United States)

Chemical looping combustion (CLC) is a process in which an oxygen carrier is used for fuel combustion instead of air or pure oxygen as shown in the figure below. The combustion is split into air and fuel reactors where the oxidation of the oxygen carrier and the reduction of the oxidized metal occur respectively. The CLC system provides a sequestration-ready CO2 stream with no additional energy required for separation. This major advantage places combustion looping at the leading edge of a possible shift in strict control of CO2 emissions from power plants. Research in this novel technology has been focused in three distinct areas: techno-economic evaluations, integration of the system into power plant concepts, and experimental development of oxygen carrier metals such as Fe, Ni, Mn, Cu, and Ca. Our recent thorough literature review shows that multiphase fluid dynamics modeling for CLC is not available in the open literature. Here, we have modified ...

2007-04-01

439

CATHENA simulation of the WOLSUNG D_20 spill incident of 1984 November 25  

International Nuclear Information System (INIS)

The CATHENA (formerly ATHENA) has been used to simulate the thermalhydraulic behaviour of the WOLSUNG-1 CANDU-600 reactor during the D_20 spill incident of 1984 November 25. A 4-inch (nominal) Liquid Relief Valve inadvertently opened in the reactor auxiliary system during normal reactor operation, resulting in a discharge of heavy water from the primary heat transport system. The valve remained open for approximately 29 minutes. CATHENA is an advanced thermalhydraulic computer code for analysis of postulated loss-of-coolant accidents (LOCA) and transient faults in CANDU nuclear reactors. A full two-fluid (six-equation) representation of the two-phase flow is used. Component models are used to represent pumps, valves, critical discharge, etc., which are necessary to describe the behaviour of the CANDU system under upset conditions. Heat transfer between the fluid and piping walls (or fuel) is modelled using applicable correlations for boiling, ...

1986-06-09

440

Braking system for use with an arbor of a microscope  

International Nuclear Information System (INIS)

A balanced braking system comprising a plurality of braking assemblies located about a member to be braked. Each of the braking assemblies consists of a spring biased piston of a first material fitted into a body of a different material which has a greater contraction upon cooling than the piston material. The piston is provided with a recessed head portion over which is positioned a diaphragm and forming a space therebetween to which is connected a pressurized fluid supply. The diaphragm is controlled by the fluid in the space to contact or withdraw from the member to be braked. A cooling device causes the body within which the piston is fitted to contract more than the piston, producing a tight shrink fit therebetween. The braking system is particularly applicable for selectively braking an arbor of an electron microscope which immobilizes, for example, a vertically adjustable low temperature specimen holder during observation. The system ...

441

Benchmark problem: Hydraulics and heat transfer in the model pin bundle with liquid metal coolant. UPV-EHU calculations  

International Nuclear Information System (INIS)

The Department of Nuclear Engineering and Fluid Mechanics in the University of the Basque Country (UPV-EHU), has done calculations for the proposed benchmark problem, in the frame of the 11th international meeting of the IAHR working group on advanced nuclear reactors thermal-hydraulics (Obninsk-Russian Federation, 5-9 July 2004). The purpose of the benchmark is to compare experimental and analytical results of some experiments carried out in the State Scientific Center of Russian Federation 'Institute of Physics and Power Engineering' (SSC RF IPPE). These experiments were held to research the cooling of pin bundles by liquid metals in reference to the core of Nuclear Reactors such as BREST. The analytical results have been done with the Computational Fluid Dynamics (CFD) code FLUENT. Temperature and velocity fields are the main variables considered for the comparison, and some assumptions has been made in order to simplify a complicate ...

2004-07-05

442

Analysis of natural convection in narrow annular gaps of LMFBR  

International Nuclear Information System (INIS)

The natural convection characteristics of gas in a vertical narrow annular gap which had its bottom opened to high temperature fluid and its upper shielding exposed to low temperature sealant have been evaluated from simulated fluid experiments using water and from calculations using the three-dimensional thermal hydraulic analysis computer code THERVIS-III. The following results were obtained: (1) The critical Rayleigh number which represented the limit of convection generation increased as the aspect ratios #epsilon#_1 (height/circumference) and #epsilon#_2 (height/gap distance) increased. (2) The flow pattern along the circumferential direction was seen to depend more strongly on the radiant heat from the side wall, rather than the aspect ratios #epsilon#_1 and #epsilon#_2. (3) The temperature difference along the circumferential direction in the annular gap obtained from the calculation code coincided with that obtained from experiments ...

443

Airflow modelling and fire smoke propagation in the new Ecole Polytechnique building  

Energy Technology Data Exchange (ETDEWEB)

A study was conducted to predict indoor ventilation, smoke movement and fire propagation in a new building currently under construction at the Ecole Polytechnique de Montreal. It was conducted in response to concerns regarding the impact that air quality, in normal operation conditions, and smoke concentration, in the event of a fire, may have on occupants of a building. A detailed three-dimensional model of the new building was constructed using the NURBS-based modeler, Rhino. Simulations of fire propagation and airflow ventilation were performed in different areas of the building. The flow pattern data was analyzed using the computational fluid dynamics (CFD) program called FLUENT. It predicted air flow conditions and estimated the mean age of air (MAA) in the room. Real-world geometries, such as diffuser inlets, have a significant impact on overall fluid flow behaviour and are necessary for this type of analysis. The fire simulation was ...

2005-07-01

444

Advanced solution algorithms for transient multidimensional thermohydraulic flow problems in complex geometries with the programme COMMIX-2/KfK  

Energy Technology Data Exchange (ETDEWEB)

The computer programme COMMIX-2 describes steady state and transient multidimensional single- and two-phase fluid flows with heat transfer in nuclear reactor components and multicomponent systems. Originally from the Argonne National Laboratory, the code has been further developed at the Kernforschungszentrum Karlsruhe. The original Point-SOR iterative method for the solution of a Poisson-like equation describing the pressure distribution in the fluid as well as the transport of enthalpy and turbulent quantities has been complemented with iterative and direct line- and block-methods. None of the newly implemented methods is original in itself but their implementation into the computer code, which can describe the most general shapes of definition domains, gave a code speed-up by a factor of 2-5, depending on the problem treated. The code capabilities are assessd by the calculation of a benchmark problem involving the numerical simulation of ...

1987-03-01

445

Advanced solution algorithms for transient multidimensional thermohydraulic flow problems in complex geometries with the programme COMMIX-2/KfK  

International Nuclear Information System (INIS)

The computer programme COMMIX-2 describes steady state and transient multidimensional single- and two-phase fluid flows with heat transfer in nuclear reactor components and multicomponent systems. Originally from the Argonne National Laboratory, the code has been further developed at the Kernforschungszentrum Karlsruhe. The original Point-SOR iterative method for the solution of a Poisson-like equation describing the pressure distribution in the fluid as well as the transport of enthalpy and turbulent quantities has been complemented with iterative and direct line- and block-methods. None of the newly implemented methods is original in itself but their implementation into the computer code, which can describe the most general shapes of definition domains, gave a code speed-up by a factor of 2-5, depending on the problem treated. The code capabilities are assessd by the calculation of a benchmark problem involving the numerical simulation of ...

1987-01-01

446

Advanced hydraulic power shovels for surface mines. Sovremennye kar'ernye gidravlicheskie odnokovshovye ehkskavatory  

Energy Technology Data Exchange (ETDEWEB)

Reviews types of hydraulic power shovels used in coal surface mines in the USA, FRG, Japan and other countries. Excavators of the first, second and third generation are compared. Hydraulic schemes of the excavators are compared. The following excavators are reviewed: the RH-75, RH-75C, 1000 SK, H-801, RC-1500, H-185, EX-1800, R-994, RH-120C, H-241, Marion 3560, H-285, EX-3500, H-485, RH-300. The following parameters are compared: mass, price, digging range, digging power, productivity, motors, travelling speed, availability coefficient, pressure in the hydraulic systems, control systems. The following elements are discussed: schemes of hydraulic drives, main motors and engines, pump stations, hydraulic equipment, hydraulic accumulators, systems for cleaning and cooling hydraulic fluids, control systems, working fluids. Reliability of hydraulic power shovels and factors that influence reliability are analyzed. 54 refs.

1989-01-01

447

A proposed methodology for computational fluid dynamics code verification, calibration, and validation  

Energy Technology Data Exchange (ETDEWEB)

Verification, calibration, and validation (VCV) of Computational Fluid Dynamics (CFD) codes is an essential element of the code development process. The exact manner in which code VCV activities are planned and conducted, however, is critically important. It is suggested that the way in which code validation, in particular, is often conducted--by comparison to published experimental data obtained for other purposes--is in general difficult and unsatisfactory, and that a different approach is required. This paper describes a proposed methodology for CFD code VCV that meets the technical requirements and is philosophically consistent with code development needs. The proposed methodology stresses teamwork and cooperation between code developers and experimentalists throughout the VCV process, and takes advantage of certain synergisms between CFD and experiment. A novel approach to uncertainty analysis is described which can both distinguish between and quantify ...

1995-07-01

448

A numerical investigation on the influence of liquid properties and interfacial heat transfer during microdroplet deposition onto a glass substrate  

CERN Document Server

This work investigates the impingement of a liquid microdroplet onto a glass substrate at different temperatures. A finite-element model is applied to simulate the transient fluid dynamics and heat transfer during the process. Results for impingement under both isothermal and non-isothermal conditions are presented for four liquids: isopropanol, water, dielectric fluid (FC-72) and eutectic tin-lead solder (63Sn-37Pb). The objective of the work is to select liquids for a combined numerical and experimental study involving a high resolution, laser-based interfacial temperature measurement to measure interfacial heat transfer during microdroplet deposition. Applications include spray cooling, micro-manufacturing and coating processes, and electronics packaging. The initial droplet diameter and impact velocity are 80 {\\mu}m and 5 m/s, respectively. For isothermal impact, our simulations with water and isopropanol show very good agreement with ...

2010-01-01

449

Vortex diode characteristics at high pressure ratios  

International Nuclear Information System (INIS)

A vortex diode has been developed as a reverse flow limiter in the primary circuit of an advanced gas cooled reactor. In addition to the development work on a prototype diode to optimise performance and geometry, measurements were also made on an available experimental diode of similar size with pressure differences up to 4 MPa and temperatures up to 600 K using nitrogen, argon and carbon dioxide as the test fluids. Correlation of data from all tests was satisfactorily obtained using isentropic one-dimensional nozzle flow equations. (author).

450

United States Gypsum Plant Solar Retrofit Program  

Energy Technology Data Exchange (ETDEWEB)

A conceptual design of a solar retrofit to US Gypsum's plant at Sweetwater, Texas, has been developed which provides heated air to a large gypsum board drying kiln that is currently under construction. The solar heated air displaces natural gas normally used for the process heat. The solar retrofit is composed of a tower focus collector with a cavity receiver which uses air as the heat transfer fluid. An executive summary of the conceptual design, system performance, economics, and development plan is presented. (WHK)

1980-07-01

451

Turbulent break-off flows  

Energy Technology Data Exchange (ETDEWEB)

Different calculated models are presented for turbulent break-off flows and their classification, reflecting the sequence of historical development. The study was done based on equations of viscous liquid of the Navier-Stokes type with development of special phenomenological models of turbulence which take into consideration real properties of the break-off flows based on simpler models of flow presented in the work. In order to calculate two-dimensional turbulent flows, a method of viscous-nonviscous interaction is used. It employs numerical solutions for nonviscous flow and integrated methods of calculating the dissipative region. This method can be extended for calculating the transonic break-off flows, and also break-off in an incompressible fluid when there is cavitation.

1982-01-01

452

Three-dimensional numerical simulation of temperature field and helium flow field in ITER China TBM  

International Nuclear Information System (INIS)

Three dimensional temperature field and helium flow field of TBM are simulated using the general purpose computational fluid dynamics (CFD) code FLUENT. The temperature distribution of Be Armor, Be Pebble Bed, Li_4SiO_4 Pebble Bed, Structure Material of TBM, and helium flow field in the cooling pipe are presented. The research indicates that the work temperature of each material is under the material temperature allowed except some places where high temperature should be excluded in the design. The results will provide references for further optimized thermal hydraulic design of ITER China TBM. (authors)

2006-02-01

453

Thermal-receiver designs for line-focus solar collectors  

Energy Technology Data Exchange (ETDEWEB)

Considerable potential exists for increasing the annual efficiency of line-focus collectors by reducing receiver heat losses. Five alternate receiver designs are compared with a standard design. The comparison is based on annual collector-field efficiency using optimized receiver designs. Of the receivers studied, the all-glass design and the cavity design provide the greatest increases in efficiency. Average fluid temperatures range from 200/sup 0/ to 450/sup 0/C. As a guide for further study, areas of uncertainty and potential problems are identified.

1982-02-01

454

The natural convection cooling with vaporizing deuterium for the horizontally arranged cold neutron source of the HFR - Grenoble  

International Nuclear Information System (INIS)

Natural convection of vaporizing Deuterium at 25 K transports the heat generated in the moderator cell of the cold neutron source to a He cooled condenser. The thermohydraulics of this thermosiphon were precalculated and the results verified by experiments in a 1:1 model using D_2 as fluid. The experimental results show that the thermosiphon operates stable. The demanded liquid content of the cell as well as wall temperatures below 50 K can be ensured by a proper design of the cell outlet flow geometry. A 7 min. loss of cryogenic power results in transient temperatures of the cell wall of not more than 300 K.

1991-08-01

455

Some rotating, time-dependent Bianchi type-IX cosmologies with heat flow  

Energy Technology Data Exchange (ETDEWEB)

Solutions are obtained for the Einstein field equations governing 40 rotating and time-dependent Bianchi type-IX cosmologies with thermal and nonthermal perfectly fluid sources. Some general properties of the solutions are discussed, and the exact computational details are given in a companion paper. All the cosmologies have spacelike, timelike or null-like homogeneous hypersurfaces depending on whether the constant alpha is less than or greater than one. The pressure of the cosmologies is assumed to be zero, and the energy density is less than zero. 9 references.

1985-06-01

456

Simulation of relative permeability hystersis to the nonwetting phase  

Energy Technology Data Exchange (ETDEWEB)

In reservoir fluid flow, the situation described by an increase in nonwetting phase saturation followed by an increase in wetting phase saturation causes a relative permeability hysteresis effect that is well known. This paper presents a method which allows the calculation of imbibition relative permeability starting at any saturation. The data required are the drainage curve, the historical maximum non wetting saturation, and a minimum of one additional point on some corresponding experimental imbibition curve. In this development, all imbibition curves are shown to be parallel. Also significant is the fact that the residual nonwetting phase saturation can be calculated without a complete experimental specification of the imbibition curve. 5 refs.

1981-01-01

457

SIMON Host Computer System requirements and recommendations  

Energy Technology Data Exchange (ETDEWEB)

Development Service Order {number_sign}90025 requested recommendations for computer hardware, operating systems, and software development utilities based on current and future SIMON software requirements. Since SIMON`s main objective is to be dispatched on missions by an operator with little computer experience, ``user friendly`` hardware and software interfaces are required. Other design criteria include: a fluid software development environment, and hardware and operating systems with minimal maintenance requirements. Also, the hardware should be expandable; extra processor boards should be easily integrated into the existing system. And finally, the use of well established standards for hardware and software should be implemented where practical.

1990-11-29

458

Role of Spiral and Multislice Computed Tomography in the evaluation of traumatic and spontaneous oesophageal perforation. Our experience  

International Nuclear Information System (INIS)

Purpose: To assess the role of CT in the evaluation of traumatic and spontaneous oesophageal perforation. Materials and methods: From March 2001 to May 2003, we studied 12 patients (7 males and 5 females; age range: 25-66 years, mean age: 43.5 years) with suspected oesophageal perforation due to motor-vehicle accidents (4 cases), stab wound (one case), post-intubation (2 cases), foreign body ingestion (2 cases) and spontaneous (3 cases). Five patients underwent standard chest and cervical radiography; two patients with suspected foreign body ingestion also underwent a gastrografin swallow study; all of the 12 patients underwent CT of the neck, chest and abdomen before and after intravenous, and in four cases oral, administration of contrast material. Results: In 5 patients with cervical, thoracic and abdominal trauma, the CT examination showed the presence of pleuroparenchymal injury (pneumothorax, pleural effusion and subcutaneous emphysema) as well as findings suggestive of ...

2005-03-01

459

Response of a magneto-rheological fluid damper subjected to periodic forcing in a high frequency limit  

British Library Electronic Table of Contents (United Kingdom)

We have explored vibrations of a single-degree of freedom oscillator with a magneto-rheological damper subjected to kinematic excitations in a high frequency limit. Using fast and slow scales decoupling procedure we derived an effective damping coefficient in the limit of high frequency excitation. Damping characteristics, as functions of velocity, change considerably especially by terminating the singular non-smoothness points. This effect was more transparent for a larger control parameter which was defined as the product of the excitation amplitude and its frequency.

2008-01-01

460

Reservoir technology research at the Idaho National Engineering Laboratory  

Energy Technology Data Exchange (ETDEWEB)

The Idaho National Engineering Laboratory (INEL) has been conducting geothermal reservoir research and testing sponsored by the US Department of Energy (DOE) since 1983. The INEL research program is primarily aimed at the development of reservoir engineering techniques for fractured geothermal reservoirs. Numerical methods have been developed which allow the simulation of fluid flow and heat transfer in complex fractured reservoirs. Sensitivity studies have illustrated the importance of incorporating the influence of fractures in reservoir simulations. Related efforts include fracture characterization, geochemical reaction kinetics and field testing.

1987-01-01

461

Radon startup analysis at a Roosevelt Hot Springs, Utah geothermal well  

Energy Technology Data Exchange (ETDEWEB)

The evaluation of radon concentration measurements in newly developing geothermal reservoirs with the objective of determining the ability of measured changes in noncondensible gas components, such as radon, to predict changes in the thermodynamic properties of the reservoir is described. This ability would be especially useful in liquid-dominated resources, where changes in steam fraction are sensitive to changes in reservoir temperature and fluid enthalpy. Radon measurements were made in samples separated by phase at the outlets of a prototype rotary separator turbine. The data were examined in relation to the thermodynamic properties of the geofluids supplied by the test well.

1983-09-01

462

Radon in unconventional natural gas from Gulf Coast geopressured-geothermal reservoirs  

International Nuclear Information System (INIS)

Radon-222 has been measured in natural gas produced from experimental geopressured-geothermal test wells. Comparison with published data suggests that while radon activity of this unconventional natural gas resource is higher than conventional gas produced in the gulf coast, it is within the range found for conventional gas produced throughout the US. A method of predicting the likely radon activity of this unconventional gas is described on the basis of the data presented, methane solubility, and known or assumed reservoir conditions of temperature, fluid pressure, and formation water salinity.

463

Quality engineering and control. Semiannual progress report, May-October 1979  

International Nuclear Information System (INIS)

The following are reported: colorimetric determination of Ti in Cr, decontamination of metals by anodic dissolution, computer code for x-ray peak identification, gel-permeation chromatography of CoRezyn 1664 polyester resin, infrared monitoring of gases and vapors, particle size analysis of dusts, nondestructive analysis of Oralloy for removable alpha contamination, dissolution (digestion) of high-fired oxides, assay of U in a Pu-U alloy, measurement of oxide thickness on Pu metal by x-ray diffraction, analysis of precipitated Pu peroxide, differentiation of Dowex SBR and 11 resins, and determination of Pu solubility in simulated lung fluid.

464

Pressure drop and heat transfer in gas-cooled rod bundles  

International Nuclear Information System (INIS)

Extensive experimental and analytical investigations of fluid flow and heat transfer in gas-cooled rod bundles have been carried out. Different bundle geometries with partially or fully roughened rod surfaces were tested in a carbon dioxide loop. An advanced and comprehensive measuring control and instrumentation are important design features of this experiment. Comprehensive thermal hydraulic subchannel analysis computer codes have been developed in order to assist fuel element design calculation for gas-cooled reactors. The experiments, codes and their verification procedure are described and the results of comparisons between measured and calculated pressure and temperature distributions are given. (orig.).

465

Preparation of silver nanofluid by the submerged arc nanoparticle synthesis system (SANSS)  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is fabrication and characterization of silver nanofluid by the submerged arc nanoparticle synthesis system (SANSS). The silver metal electrodes under the electrical discharge will melt and evaporate rapidly and condense to form the nanoparticles in the lower temperature dielectric liquid and produce the suspended nanoparticle. The results showed that the spherical nanosilver particle formed in the ethylene glycol and the mean particle size is about 12.5 nm. The prepared silver nanofluid was irradiated under the 410 nm visible light, electrons could be excited from the valence band to the conduction band. The silver nanofluid more closely resembles Newtonian fluids.

2007-05-31

466

Pitting corrosion of steel pipeline in oil-water-gas multiphase flow system  

Energy Technology Data Exchange (ETDEWEB)

Severe pitting corrosion occurred in a horizontal steel pipeline used to transport multiphase fluid, including water, oil, and natural gas, after 2 months of service. The pitting corrosion rate was up to 42 mm/year. Chemical analysis, X-ray diffractometry, and EDAX showed that the corrosion products mainly consisted of Fe9S8, FeCO3, and NaCl. Calcium containing inclusions were also found in the matrix of the steel, which may accelerate corrosion. The early failure was attributed to the high proportion of water, the slow flow velocity, and the use of unqualified material. (Author)

2000-07-01

467

Physical characteristics and solubility of long-lived airborne particulates in uranium producing and manufacturing facilities: A report upon completion of the extension to Phase I of the study. Research report No. INFO-0363-1  

Energy Technology Data Exchange (ETDEWEB)

Study of the rate of dissolution in simulated lung fluid of uranium from 3 different ore matrices and from refined uranium dioxide in an essentially all teflon extraction apparatus; the rate of dissolution of thorium from a nickel metal/2 percent thoria mixture; the effect of neutron irradiation of the studied materials upon the dissolution rates; and the adsorptions of the radioisotope tracers barium 133 (substitute for radium), lead 203 and thorium 234 upon the extraction system components.

1989-01-01

468

On-line partial discharge measurements and off-line dielectric spectroscopy measurements of six 115 kV XLPE cable systems  

Energy Technology Data Exchange (ETDEWEB)

This paper reported on a study in which partial discharge (PD) measurements were performed on 6 underground transmission cable circuits to determine the effectiveness of PD measurements on fluid fill cables. The cables were between 37 and 56 years old. PD activity was detected from the terminations of H11L and H3L Cable 2. However, for cables from H3L Basin TS to Mill Street junction, PD activity was detected originating from within the main cable insulation.

2009-07-01

469

On the stability of the Einstein static universe  

Energy Technology Data Exchange (ETDEWEB)

We show using covariant techniques that the Einstein static universe containing a perfect fluid is always neutrally stable against small inhomogeneous vector and tensor perturbations and neutrally stable against adiabatic scalar density inhomogeneities so long as c{sup 2}{sub s} > 1/5, and unstable otherwise. We also show that the stability is not significantly changed by the presence of a self-interacting scalar field source, but we find that spatially homogeneous Bianchi type IX modes destabilize an Einstein static universe. The implications of these results for the initial state of the universe and its pre-inflationary evolution are also discussed. (letter to the editor)

2003-06-07

470

On the stability of the Einstein static universe  

International Nuclear Information System (INIS)

We show using covariant techniques that the Einstein static universe containing a perfect fluid is always neutrally stable against small inhomogeneous vector and tensor perturbations and neutrally stable against adiabatic scalar density inhomogeneities so long as c"2_s > 1/5, and unstable otherwise. We also show that the stability is not significantly changed by the presence of a self-interacting scalar field source, but we find that spatially homogeneous Bianchi type IX modes destabilize an Einstein static universe. The implications of these results for the initial state of the universe and its pre-inflationary evolution are also discussed. (letter to the editor)

2003-06-07

471

On the Permeability of Thermally Damaged PBX 9501  

British Library Electronic Table of Contents (United Kingdom)

Theoretical analysis, modeling, and simulation are used to provide insight into the development of permeability during thermal damage of the high explosive PBX 9501. In a recently published article, Terrones et al. [1] conclude that samples of PBX 9501 thermally damaged at 186 degreeC are not permeable to gas flow in a manner consistent with Darcys Law. We disagree with their conclusion. We show that they have misreported data from the literature, and that their argument depends on a fluid flow model that is physically incorrect and is applied with inappropriate physical parameters.

2007-01-01

472

Nonlinear dynamics of heat transfer enhancement using eddy promoters  

Science.gov (United States)

This investigation concerns the nonlinear dynamics of heat transfer from a surface using an upstream eddy promoter. A numerical model is developed for the coupled fluid flow and heat transfer process based on a modified MacCormack scheme. Numerical simulations are carried out to determine the response and heat transfer enhancement due to the promoter. The average heat transfer from a cavity floor is seen to be increased by a factor of approximately five over the unpromoted'' flow. Another interesting feature of the study is the nonlinear viscous flow dynamics from the cylinder-wall interaction which differ significantly from the familiar cylinder-free stream patterns.

1994-02-01

473

Nonlinear dynamics of heat transfer enhancement using eddy promoters  

Energy Technology Data Exchange (ETDEWEB)

This investigation concerns the nonlinear dynamics of heat transfer from a surface using an upstream eddy promoter. A numerical model is developed for the coupled fluid flow and heat transfer process based on a modified MacCormack scheme. Numerical simulations are carried out to determine the response and heat transfer enhancement due to the promoter. The average heat transfer from a cavity floor is seen to be increased by a factor of approximately five over the unpromoted'' flow. Another interesting feature of the study is the nonlinear viscous flow dynamics from the cylinder-wall interaction which differ significantly from the familiar cylinder-free stream patterns.

1994-02-01

474

Non-traumatic thoracic emergencies: imaging and treatment of thoracic fluid collections (including pneumothorax)  

International Nuclear Information System (INIS)

Cross-sectional imaging has revolutionised the radiological diagnosis of pleural collections. Not only can the precise location and volume of a pleural effusion be established, but also features specific for the aetiology of the effusion can be demonstrated. Increasingly, radiologists are called upon to perform image-guided biopsies, aspirations and small bore chest drain placement, all of which have been shown to be safe and efficacious. Pneumothoraces occurring due to acute trauma and in an intensive care setting can also benefit from radiological input, both in terms of diagnosis and image-guided treatment. (orig.)

2002-08-01

475

Nippon Kokan technical report, No. 108, July 1985  

Energy Technology Data Exchange (ETDEWEB)

Contents include: countermeasures to save energy of sintering plant and future plans in fukuyama works; improvement of surface quality of continuous-casting slab; development of direct quenching and tempering type HT80 steel with good weldability; numerical analysis of fluid flow in a geothermal reservoir; the finite-element calculation of turbulent flow using the universal law of the wall; development of PC 4 dual fuel engine; design of industrialized housing; Computer-aided Navigation system (CANSY); and new production control system in Fukuyama Works.

1985-01-01

476

Loaded Transducer Fpr Downhole Drilling Component  

Energy Technology Data Exchange (ETDEWEB)

A robust transmission element for transmitting information between downhole tools, such as sections of drill pipe, in the presence of hostile environmental conditions, such as heat, dirt, rocks, mud, fluids, lubricants, and the like. The transmission element maintains reliable connectivity between transmission elements, thereby providing an uninterrupted flow of information between drill string components. A transmission element is mounted within a recess proximate a mating surface of a downhole drilling component, such as a section of drill pipe. To close gaps present between transmission elements, transmission elements may be biased with a "spring force," urging them closer together.

2005-07-05

477

Literature and patent searches on the subject of controllable heat transfer. Final report. Literatur- und Patentrecherche zum Thema Schaltbarer Waermedurchgang. Abschlussbericht  

Energy Technology Data Exchange (ETDEWEB)

The possibility of switching the heat transfer consists of varying heat transfer surfaces and making the heat transfer temporarily more intensive. Heat tubes prove to be particularly suitable, which must be exposed to a heat carrier fluid or removed from its effect for switching the heat transfer. This report gives a survey of the possibilities of switching heat flows and for making the heat transfer more intensive. Further, the report contains a survey of patents limited to heat transfer in the fields of cooling internal combustion engines and exhaust systems. (orig.) With 17 figs., 183 refs.

1989-01-01

478

Integration of direct solar steam collectors in steam cycle power plants; Einkopplung von direktverdampfenden Parabolrinnenkollektoren in Dampfkraftwerke  

Energy Technology Data Exchange (ETDEWEB)

The restricted temperature stability of the synthetic thermal oil which is used as heat carrier fluid in parabolic trough collectors so far limits the live steam parameters in the steam cycle to approximately 375 Celsius. In order to break through this limit, already for quite some time it is researched to replace the thermal oil by boiler feeding waters and to accomplish the evaporation in the collectors. The contribution under consideration gives an overview on the direct evaporation concept and summarizes the past operational experiences. Moreover, the challenges with the integration of this technology in a steam turbine cycle are elaborated.

2008-07-01

479

Improvement of assessment methodology for fluid flow characteristics of passive flow control device  

International Nuclear Information System (INIS)

The objective of this study is to establish evaluation and verification guideline for the APR 1400 and to investigate the thermal-hydraulic characteristics for fluidic device is analyzed using FLUENT. The scope and major results of research are flow characteristics for fluidic device. In this study, three-dimensional numerical model for fluidic device is developed adequately for, and results are compared with experimental data performed by VAPER (VAlve Performance Evaluation test Rig) in KAERI with an aim to verify numerical simulation. In addition, the parametric study has also carried out to investigate the effect of major parameters such as velocity and pressure inside FD chamber.

2002-10-01

480

Hydraulic braking system for loads subjected to impacts and vibrations  

International Nuclear Information System (INIS)

This invention concerns a hydraulic braking system for loads subjected to impacts and vibrations. These double acting telescopic type hydraulic braking systems possess significant drawbacks linked to possibly important hydraulic leaks due to (a) the use of many dynamic seals in such appliances and (b) the effects of the environment of the system on these seals, particularly when employed in nuclear power stations where the seals reach significant temperatures and are subjected to radiation. Under this invention a remedy is suggested to such drawbacks by integrating means to offset automatically the leaks and the accumulation of hydraulic fluid expansions, as well as facilities to show if such leaks have occurred.

481

Geothermal applications for a tannery  

Energy Technology Data Exchange (ETDEWEB)

The tanning process and associated energy requirements are summarized. It appears that a significant economic impact may be possible if a shallow hydrothermal resource of approximately 150 to 170/sup 0/F (66 to 77/sup 0/C) were found, and the fluids were cascaded to produce the temperatures necessary for the various tanning operations. The hydrothermal energy would have to be cost competitive with the rapidly escalating fossil energy costs. Although one would need to thoroughly analyze the technical, environmental, and economic issues of such an application, this initial review indicates a good match between the process and potential hydrothermal resources.

1982-02-01

482

Film condensation of HCFC-22 on horizontal enhanced tubes  

Science.gov (United States)

Experiments were conducted to study the condensation heat transfer characteristics of horizontal enhanced tubes. In the current experiment, six different enhanced tubes, including 26, 40 fpi low fin tubes and four three-dimensional-fin tubes, were tested. The working fluid used in the experiment was HCFC-22. Data were presented in the form of overall heat transfer coefficient at three working pressures, namely 1.32, 1.47 and 1.62 Mpa. In addition, the condensing heat transfer coefficients for the test tubes were obtained from the Wilson plot technique.

1996-01-01

483

Establishing the limiting conditions of operation of magneto-rheological fluid dampers in vehicle suspension systems  

British Library Electronic Table of Contents (United Kingdom)

This paper deals with dynamical behavior of a nonlinear suspension system. We examine chaotic motion in a vehicle suspension system with hysteretic nonlinearity excited by a road profile. A one degree of freedom quarter-car model with nonsymmetric potential is investigated. The Melnikov criterion is used to study the intersection of stable and unstable manifolds and transition to chaos for the system. The condition for chaotic vibration is found using a Melnikov function. Chaotic motion also is indicated by a bifurcation diagram and Lyapunov exponents.

2009-01-01

484

Cupola modeling research: Phase 2 (Year one), Final report  

Energy Technology Data Exchange (ETDEWEB)

Objective was to develop a mathematical model of the cupola furnace (cast iron production) in on-line and off-line process control and optimization. In Phase I, the general structure of the heat transfer, fluid flow, and chemical models were laid out, providing reasonable descriptions of cupola behavior with a one-dimensional representation. Work was also initiated on a two-dimensional model. Phase II was focused on perfecting the one-dimensional model. The contributions include these from MIT, Michigan University, and GM.

1991-11-20

485

Cosmic no hair for collapsing universes  

Energy Technology Data Exchange (ETDEWEB)

It is shown that all contracting, spatially homogeneous, orthogonal Bianchi cosmologies that are sourced by an ultra-stiff fluid with an arbitrary and, in general, varying equation of state asymptote to the spatially flat and isotropic universe in the neighbourhood of the big crunch singularity. This result is employed to investigate the asymptotic dynamics of a collapsing Bianchi type IX universe sourced by a scalar field rolling down a steep, negative exponential potential. A toroidally compactified version of M*-theory that leads to such a potential is discussed and it is shown that the isotropic attractor solution for a collapsing Bianchi type IX universe is supersymmetric when interpreted in an 11-dimensional context.

2006-05-21

486

Conception and design of steam power plants  

International Nuclear Information System (INIS)

The manual presents the fundamentals of thermodynamics and fluid mechanics, the main components of steam power plants, and the power generation process. The following concepts and subjects are discussed at length: steam generator; steam turbines; turbogenerators; condensers; cooling technology; water/steam cycle and water treatment; design data of fossil-fuelled power plants; design and optimisation of nuclear power plant thermodynamics; pipelines and fittings; control systems in steam power plants; connection to the electricity grid and self-supply of thermal power plants; power plant transformer concepts and definitions. (HAG).

487

Characterization of jet breakup mechanisms observed from simulant experiments of molten fuel penetrating coolant  

Science.gov (United States)

The goal of this research program has been to add to our understanding of the breakup of molten fuel jets penetrating reactor coolant. Easily handled working fluids are used to simulate fuel jet breakup, so that detailed observations may be obtained from a relatively large number of experiments. The tools used for observing this behavior are high speed notion picture photography, Flash X-radiography, and X-ray cine. Jet breakup lengths are determined from motion pictures; the mechanisms by which the jets are fragmented may be inferred from radiographs.

1992-01-01

488

Characterization of Mixed Wettability at Different Scales and its Impact on Oil Recovery Efficiency  

Energy Technology Data Exchange (ETDEWEB)

The objectives of this project was to: (1) quantify the pore scale mechanisms that determine the wettability state of a reservoir, (2) study the effect of crude oil, brine and mineral compositions in the establishment of mixed wet states, (3) clarify the effect of mixed - wettability on oil displacement efficiency in waterfloods, (4) develop a new tracer technique to measure wettability, fluid distributions, residual saturation's and relative permeabilities, and (5) develop methods for properly incorporating wettability in up-scaling from pore to core to reservoir scales.

2002-01-28

489

Automatic control of the Wattenberg Gas Field, Colorado  

Energy Technology Data Exchange (ETDEWEB)

This paper discusses the successful implementation of automatic control in the Wattenberg Gas Field in northern Colorado. Also discussed is the use of solar powered Amocams equipment to affect continuous monitoring and control of these tight gas wells. The control system includes an algorithm which continuously adjusts the production cycling based on changes in the individual well's producing pressures and flow rates. This strategy has been successful in enhancing production and reducing the number of wells logged off due to excessive fluid buildup. The benefits derived from this system are enumerated and the impacts on field operations are discussed.

1982-09-01

490

Application of porous media approach for multi-dimensional analysis of thermal hydraulic system analysis code, MARS  

Energy Technology Data Exchange (ETDEWEB)

The Porous media approach method was applied to the MULTID component of MARS which was developed by KAERI. This method has been widely used for analysis of large regions containing only fluid and for flows in regions with immersed solids. It can calculate flow distribution more correctly in case of flow area or volume change. Application of this method to the MULTID component in MARS was evaluated and the results were compared with those of CFD code, FLUENT. As a result, the calculated flow distributions of MARS and FLUENT show similar trend, so the effect of porous media in MARS can be applied to the other cases.

2003-10-01

491

Anisotropic mass density by two-dimensional acoustic metamaterials  

Energy Technology Data Exchange (ETDEWEB)

We show that specially designed two-dimensional arrangements of full elastic cylinders embedded in a nonviscous fluid or gas define (in the homogenization limit) a new class of acoustic metamaterials characterized by a dynamical effective mass density that is anisotropic. Here, analytic expressions for the dynamical mass density and the effective sound velocity tensors are derived in the long wavelength limit. Both show an explicit dependence on the lattice filling fraction, the elastic properties of cylinders relative to the background, their positions in the unit cell, and their multiple scattering interactions. Several examples of these metamaterials are reported and discussed.

2008-02-15

492

Anesthetic considerations for nontransplant procedures in lung transplant patients  

British Library Electronic Table of Contents (United Kingdom)

Lung transplantation has become an accepted option for many patients with end-stage pulmonary diseases. Anesthesia and surgery following lung transplantation may be required for various diseases that may affect both systemic organs and the transplanted graft. When a patient with a lung transplant undergoes surgery, there is the potential for interference with lung function, depending on the type of intervention and its anatomical site. Accurate preoperative evaluation, an understanding of the physiology of the transplanted lung, proper airway instrumentation, individualized management of intraoperative ventilation, and fluid balance are essential for a positive perioperative outcome.

2011-01-01

493

Analysis of laminar flow and heat transfer in the entrance region of an internally finned concentric circular annular duct  

Energy Technology Data Exchange (ETDEWEB)

The concentric circular annular duct is a common geometry in many fluid flow and heat transfer devices. For the purpose of heat transfer augmentation, fins are often employed in the annular region, and such finned ducts find wide application in compact heat exchangers (5, 6). The analysis of flow and heat transfer in this geometry is, therefore, quite important from an engineering standpoint. For fully developed conditions, the problem has already been analyzed (7-10). However, no results are available for the developing flow in the entrance region. It is with this latter problem that the present paper is concerned.

1987-05-01

494

A thermal hydraulic investigation on ADSR liquid lead target  

Energy Technology Data Exchange (ETDEWEB)

Computational fluid dynamics(CFD) code FLUENT was used to simulate the thermal hydraulic processes occurring in conceptual design of the accelerator-driven subcritical reactor(ADSR) liquid lead target. The purpose of the analysis is to investigate the thermal hydraulic characteristics of liquid lead as ADSR target material with various target geometries and injection locations of proton beam. In the calculation analysis, the local temperature of the liquid lead target rises to the boiling temperature very rapidly. When the proton beam is injected from the bottom of the target system, the duration time to reach the boiling temperature is longer and the temperature distribution is flatter than other cases.

1998-05-01

495

A study on the response time characteristics related to shock control in the hydraulic system using the fluid device  

International Nuclear Information System (INIS)

Control of pressure transients in a hydraulic system may be important and necessary to avoid failures and to improve the efficiency of operation. Flow restricting devices can result in a decrease in the peak pressure, but may change the response time. The response time has an important effect on both operator and operator perceived smoothness. The response time should correspond to how fast a system responds to a given disturbance at the system boundary. Occasionally the appropriate response time is not easily determined. This study is on the response time characteristics in the hydraulic system studied for the control of response time.

2001-11-01

496

A simplified approach to the drying of solids in a batch fluidised bed  

Scientific Electronic Library Online (English)

Abstract in english A simplified model for drying solids in the constant rate period in a batch fluidised bed was developed.It assumes the bed to be divided into dense and bubble phases with heat and mass transfer between the phases.The model predicts the constant-rate drying period, provided the fluid bed shape and material characteristics are known.The model is compared with experimental data reported in the literature covering a wide range of materials, gas flow rates, column diameters, m (more) aterial hold-ups, air temperatures and humidities.Model predictions compare satisfactorily with the experimental data.

2002-07-01

497

A new proof of the Bianchi type IX attractor theorem  

Energy Technology Data Exchange (ETDEWEB)

We consider the dynamics toward the initial singularity of Bianchi type IX vacuum and orthogonal perfect fluid models with a linear equation of state. The 'Bianchi type IX attractor theorem' states that the past asymptotic behavior of generic type IX solutions is governed by Bianchi type I and II vacuum states (Mixmaster attractor). We give a comparatively short and self-contained new proof of this theorem. The proof we give is interesting in itself, but more importantly it illustrates and emphasizes that type IX is special, and to some extent misleading when one considers the broader context of generic models without symmetries.

2009-04-07

498

A new proof of the Bianchi type IX attractor theorem  

International Nuclear Information System (INIS)

We consider the dynamics toward the initial singularity of Bianchi type IX vacuum and orthogonal perfect fluid models with a linear equation of state. The 'Bianchi type IX attractor theorem' states that the past asymptotic behavior of generic type IX solutions is governed by Bianchi type I and II vacuum states (Mixmaster attractor). We give a comparatively short and self-contained new proof of this theorem. The proof we give is interesting in itself, but more importantly it illustrates and emphasizes that type IX is special, and to some extent misleading when one considers the broader context of generic models without symmetries.

2009-04-07

499

A new proof of the Bianchi type IX attractor theorem  

CERN Document Server

We consider the dynamics towards the initial singularity of Bianchi type IX vacuum and orthogonal perfect fluid models with a linear equation of state. The `Bianchi type IX attractor theorem' states that the past asymptotic behavior of generic type IX solutions is governed by Bianchi type I and II vacuum states (Mixmaster attractor). We give a comparatively short and self-contained new proof of this theorem. The proof we give is interesting in itself, but more importantly it illustrates and emphasizes that type IX is special, and to some extent misleading when one considers the broader context of generic models without symmetries.

2009-01-01

500

A critical study of poiseuille flow of couple stress fluid with applications to blood flow  

Science.gov (United States)

It is shown that the method used for comparing theoretical and experimental results is erroneous and the values of the couple stress parameters obtained for blood flow are incorrect. A method for determining the couple stress parameters is presented. The computational work in the improved method is considerably less. It is observed that both the couple stress parameters are functions of concentration. An empirical relation between concentration and the stress parameters is obtained. The shear viscosity and non-dimensional axial velocity are functions of concentration. Some uses of determining the values of the couple stress parameters are suggested.

1981-01-01