WorldWideScience
1

CT versus MRI in the study of the articular diseases of the knee  

International Nuclear Information System (INIS)

The authors present a comparison between the diagnostic accuracy of Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) in the articular pathologies of the knee. CT and MRI were performed in 30 patients who subsequently underwent surgery. CT and MRI results were compared on three bases: technique, definition of normal anatomy, and diagnostic accuracy. CT allowed a standardization of the technique, while MRI was superior in defining normal anatomy - especially in the study of capsulo-ligamentous structures. In all cases the use of both CT and MRI allowed a correct diagnosis, showing the site, extent and gravity of the lesion. CT proved to be superior to MRI in 4 cases, while MRI corrected CT diagnosis in 11 cases; in 15 patients both techniques had the same diagnostic accuracy. Meniscal tears were better identified by CT, while MRI was superior in the detection of ligamentous lesions and in the ...

1988-01-01

2

SLAP Tears  

Science.gov (United States)

... your upper arm bone (humerus), your shoulder blade (scapula), and your collarbone (clavicle). The head of your ...

4

Tear Lipocalin Captures Exogenous Lipid from Abnormal Corneal Surfaces  

UK PubMed Central (United Kingdom)

Purpose.The cornea is protected by apical hydrophilic transmembrane mucins and tears. In pathologic states the mucin barrier is disrupted, creating potential for meibomian lipids...Full Text Available

2010-04-01

5

Liver trauma from penetrating injuries. Miscellanea, personal series, clinical and CT findings  

International Nuclear Information System (INIS)

Penetrating liver wounds are related to many causes and rank second after blunt abdominal and liver trauma. In this report are examined the clinical and radiological findings of personal series of patients with penetrating trauma, especially by firearms and stab and cut wounds. It will also tried to define the diagnostic workup of these traumas, which is especially based on CT signs of liver damage and associated changes and which is of basic importance for following treatment, both surgical or conservative. In the last seven years it was retrospectively reviewed 31 cases of penetrating liver trauma. The patients were 19 men and 12 women, ranging in age 18 to 73 (mean 42), with penetrating liver injuries from firearms (16 patients) and stab (9 cases) wounds; 6 patients had injuries from different cases. Abdominal CT was carried out in emergency with the CT Angiography (CTA) technique in all patients. In the patients with suspected chest and abdomen involvement CT ...

2000-12-01

6

Tear Strength of Elastomers under Threshold Conditions  

Science.gov (United States)

... the Naval Research Laboratory (Contract NOOO14-82-K-2015), Cabot Corporation, and Lord Kinematics Division of Lord Corporation. The authors ...

1983-04-01

7

NASA SBIR 98-1 Award by Firm - NASA's SBIR & STTR Programs  

Science.gov (United States)

Design of Damage-Tolerant Composite Sandwich Panels with Tear Straps. Sukra Helitek Inc. 3146 Greenwood Road. Ames, IA 50014-4504 ...

8

Design of Damage-Tolerant Composite Sandwich Panels with Tear Straps  

Science.gov (United States)

The objectives of the Phase-I research address the development of mechanics- based structural integrity analysis methodologies for composite sandwich panels ...

9

SBIR 98-I Awards by Topic - NASA's SBIR & STTR Programs  

Science.gov (United States)

... NC 27605 Winnie Liao (919) 821-5950 98-1-02.01-5950 LaRC Design of Damage- Tolerant Composite Sandwich Panels with Tear Straps American Technology ...

10

Experience of static electrification in power transformer  

Energy Technology Data Exchange (ETDEWEB)

This document is a discussion of a static electrification event in each of the 1050 MVA units installed at the Koeburg Nuclear Power Plant in South Africa. Results of a tear-down inspection performed after the event are given, as is an analysis of the event. A number of photographs are included.

1995-05-01

11

Computed tomography whole body imaging in multi-trauma: 7 years experience  

International Nuclear Information System (INIS)

AIM: To assess the impact of the introduction of a computed tomography (CT) imaging protocol for multi-trauma patients on the workload, overall diagnostic yield, and effect on detection of cervical spine injury and pneumothorax. METHOD: Between February 1997 and April 2004, all patients presenting acutely to the Emergency Department (ED) with haemodynamically stable trauma (Abbreviated Injury Scale 3 or more) involving more than two body systems were imaged with a comprehensive pre-set helical CT protocol (including non-contrast head, cervical spine: cranio-cervical and cervico-thoracic junctions; and oral and intravenous contrast-enhanced thoracic, abdomen and pelvis) after initial triage and a standard trauma series of radiographs (chest, lateral C-spine and pelvis). Diagnosis of cervical spine fracture and pneumothorax was noted before and after the CT protocol was carried out and findings from all studies were recorded prospectively. RESULTS: Over the 7-year ...

2006-04-01

12

Comparison of CT and MRI in patients with tibial plateau fracture: can CT findings predict ligament tear or meniscal injury?  

Energy Technology Data Exchange (ETDEWEB)

(1) To determine the accuracy of computed tomography (CT) in the evaluation of ligament tear and avulsion in patients with tibial plateau fracture. (2) To evaluate whether the presence or severity of fracture gap and articular depression can predict meniscal injury. A fellowship-trained musculoskeletal radiologist retrospectively reviewed knee CT and MRI examinations of 41 consecutive patients presenting to a level 1 trauma center with tibial plateau fractures. Fracture gap, articular depression, ligament tear and footprint avulsions were assessed on CT examinations. The MRI studies were examined for osseous and soft tissue injuries, including meniscal tear, meniscal displacement, ligament tear, and ligament avulsion. CT demonstrated torn ligaments with 80% sensitivity and 98% specificity. Only 2% of ligaments deemed intact on careful CT evaluation had partial or complete tears on ...

2007-02-15

13

Chemical Reactor Diagnostics  

International Science & Technology Center (ISTC)

Development of Methods and Apparatus for Processes Diagnostics in Plasma Reactors at the Neutralization of Chemical Herbiside and Pestiside

14

Beam Diagnostic System for High Intensity Proton Linac at KAERI  

CERN Document Server

Beam Diagnostic System for High Intensity Proton Linac at KAERI

2003-01-01

15

MRI in definition of bleeding source, lesion pattern and therapy in haemarthros of the knee  

International Nuclear Information System (INIS)

Patients with haemarthros of the knee were examined by MRI and arthroscopy to identify the bleeding source and to determine surgical or conservative therapy. A prospective study was performed on 120 patients who underwent MRI and arthroscopy, point lesions and bleeding sources were documented separately on a standardised form. Arthroscopy demonstrated a ruptured anterior cruciate ligament in 86%, meniscal tears in 55%, disruption of collateral ligaments in 17%, osteochondral lesions in 5% and tears of capsule or plicae in 13%. Disruption of cruciate ligaments caused haemorrhage in all but three cases. In contrast, only meniscal tears located very adjacent to the meniscal basement had bled. Those types of osteochondral lesions caused haemorrhage characterised on MRI by destruction of the subchondral plate and overlying cartilage. Severe lesions of the knee were diagnosed by MRI in 71% to 100%, slight lesions in 13% to 40% of ...

16

Post-lens tear-film depletion due to evaporative dehydration of a soft contact lens  

British Library Electronic Table of Contents (United Kingdom)

For a soft-contact-lens (SCL) wearer, corneal health and comfort are strongly influenced by water transport through the polymeric materials used in lens fabrication. In particular, evaporative water loss at the anterior lens surface is a potential cause of contact-lens dehydration and of post-lens tear-film depletion, which in turn, may lead to discomfort, dryness syndrome, and/or lens adhesion.We present a solution-diffusion model for transport of water through soft-contact-lens materials to mimic evaporative dehydration from a contact lens during blinking and to access possible SCL adhesion to the corneal surface under a variety of environmental conditions (e.g., wind speed and relative humidity). To describe the water-transport process, we use an extended version of the Maxwell-Stefan m...

2006-01-01

18

Modern Optical Diagnostics for Technical Combustion Research  

ScienceCinema

...different sparking language english ? ...

20

Diagnostic radiology: An Anglo-American textbook of imaging  

Energy Technology Data Exchange (ETDEWEB)

This multiauthored text is aimed particularly toward the resident or registrar training in diagnostic radiology. This is a text book on the entire scope of diagnostic imaging. It includes techniques and imaging modalities of all the systems, head, face and neck. The book covers the entire gamut of diagnostic radiology.

1986-01-01

21

Association between meniscal tears and the peak external knee adduction moment and foot rotation during level walking in postmenopausal women without knee osteoarthritis: a cross-sectional study  

UK PubMed Central (United Kingdom)

IntroductionMeniscal injury is a risk factor for the development and progression of knee osteoarthritis, yet little is known about risk factors for meniscal pathology. Joint loading...Full Text Available

2008-01-01

22

Liver trauma from penetrating injuries. Miscellanea, personal series, clinical and CT findings; Traumi epatici da lesioni penetranti. Miscellanea, casistica personale, aspetti clinici e con Tomografia Computerizzata  

Energy Technology Data Exchange (ETDEWEB)

Penetrating liver wounds are related to many causes and rank second after blunt abdominal and liver trauma. In this report are examined the clinical and radiological findings of personal series of patients with penetrating trauma, especially by firearms and stab and cut wounds. It will also tried to define the diagnostic workup of these traumas, which is especially based on CT signs of liver damage and associated changes and which is of basic importance for following treatment, both surgical or conservative. In the last seven years it was retrospectively reviewed 31 cases of penetrating liver trauma. The patients were 19 men and 12 women, ranging in age 18 to 73 (mean 42), with penetrating liver injuries from firearms (16 patients) and stab (9 cases) wounds; 6 patients had injuries from different cases. Abdominal CT was carried out in emergency with the CT Angiography (CTA) technique in all patients. In the patients with suspected chest and abdomen involvement CT ...

2000-12-01

23

Neutron detection techniques for plasma diagnostics at the Joint European Torus (JET)  

International Nuclear Information System (INIS)

The importance of neutron measurements both as a succinct measure of the progress to fusion ignition using the magnetic confinement route and also as a diagnostic of plasma conditions is discussed. The various neutron diagnostic systems that have been or are being constructed by AERE Harwell for JET are described. The properties to be measured by such diagnostics are clearly identified and some results obtained with the installed diagnostics during d-d plasmas are presented.

24

Proton storage ring (PSR) diagnostics and control system  

Energy Technology Data Exchange (ETDEWEB)

When any new accelerator or storage ring is built that advances the state of the art, the diagnostic system becomes extremely important in tuning the facility to full specification. This paper will discuss the various diagnostic devices planned or under construction for the PSR and their connection into the control system.

1983-01-01

25

Probabilistic fracture assessment of surface cracked pipes using strain-based approach  

British Library Electronic Table of Contents (United Kingdom)

Simplified strain-based fracture mechanics equations, established for external surface cracked pipelines subjected to an external bending load, are presented and used in probabilistic assessment of a pipeline girth weld. The model takes into account several parameters, such as variation in crack depth, crack length, internal pressure and material hardening. The critical strain from ductile tearing in the cracked pipeline is found by using the tangency criterion. The reliability problem is solved using first and second order reliability methods for different pipe dimensions and load levels.

2006-01-01

26

The Development of a Dental Diagnostic Terminology  

UK PubMed Central (United Kingdom)

There is no commonly accepted standardized terminology for oral diagnoses. The purpose of this article is to report the development of a standardized dental diagnostic terminology by a work...Full Text Available

2011-01-01

30

ELECTRICAL AND DIAGNOSTIC ASPECTS OF ELECTROHYDRAULIC AND MAGNETIC FORMING  

Science.gov (United States)

Discussion of an electrohydraulic and magnetic forming process

1963-01-01

34

CT colonography. Virtual coloscopy; CT-Kolonographie. Virtuelle Koloskopie  

Energy Technology Data Exchange (ETDEWEB)

The CT colonography or virtual coloscopy is a new diagnostic method that allows the presentation of the whole colon using minimal invasive procedures. The method allows the detection of colorectal polyps and colorectal carcinomas. The book includes the following chapters: indications for CT colonography, diagnostic procedures, data processing and interpretation, diagnostic findings, preparation of the diagnostic result description and documentation, screening.

2009-07-01

36

Alternative Technologies for Medical Radionuclide Production  

International Science & Technology Center (ISTC)

Creation of Economic Alternative Technologies for Radionuclide Production for Medical Diagnostics and Therapy

37

Diagnostics hardening for harsh environment in Laser Megajoule (invited)  

International Nuclear Information System (INIS)

The diagnostic designs for the Laser Megajoule (LMJ) will require components to operate in environments far more severe than those encountered in present facilities. This harsh environment will be induced by fluxes of neutrons, gamma rays, energetic ions, electromagnetic radiations, and, in some cases, debris and shrapnel, at levels several orders of magnitude higher than those experienced today on existing facilities. The lessons learned about the vulnerabilities of present diagnostic parts fielded mainly on OMEGA for many years, have been very useful guide for the design of future LMJ diagnostics. The present and future LMJ diagnostic designs including this vulnerability approach and their main mitigation techniques will be presented together with the main characteristics of the LMJ facility that provide for diagnostic protection.

2008-10-01

38

Diagnostic quality in hysterosalpingography  

International Nuclear Information System (INIS)

Purpose: To compare the diagnostic quality and adverse events of the water-soluble, non-ionic, iso-osmolar, dimeric contrast media iodixanol and iotrolan in hysterosalpingography (HSG). Material and Methods: One hundred and twenty patients participated in a double-blind randomized parallel-group phase-III study. Questionnaires and patient interviews were used. Diagnostic quality was assessed using a visual analogue scale and the quality in specific regions was rated using a categorical scale. Results: Overall diagnostic quality was equal for the two groups. There was no statistically significant difference between the two groups in diagnostic quality in the specific regions of interest. No differences between the contrast media were found with regard to adverse events. Conclusion: Both contrast media provided images of high diagnostic quality in HSG. (orig.)

1998-11-01

39

Wave electromagnetic fields induced by instantaneous braking of charges  

International Nuclear Information System (INIS)

Exact expressions for wave electromagnetic fields during instantaneous braking of two differently charged discs uniformly moving in the opposite directions have been derived. Analysis of their properties has been made. It is shown that electromagnetic wave fields during instantaneous braking of charges have a tearing nature and the Umov-Poynting theorem in the integral form is realized only at a certain value of parameter #alpha# which determines charges rates at the moment of braking. The value of parameter #alpha# is in the ranges from 0.5 to #sq root#3/2. The wave field is formed already in the absence of motion of charged discs. It is a good example confirming the conclusion that in the case of nonstationary electromagnetic fields, performance of reaction force of the wave field can differ fram radiation energy.

40

Silica-reinforced natural rubber prepared by the sol-gel process of ethoxysilanes in rubber latex  

British Library Electronic Table of Contents (United Kingdom)

Silica-reinforced natural rubber (NR) composite was prepared by using tetraethoxysilane (TEOS) as a precursor to generate silica particles inside the rubber. The silica was generated in situ by the sol-gel process of TEOS that was mixed directly into commercial-graded NR latex having 60% dry rubber content and 0.7% ammonia. The conversions of TEOS to silica inside the rubber were ranging from 90 to 97%. The silica particles dispersed evenly without extensive aggregation with sizes between 100 and 500 nm, as determined by scanning electron microscopy (SEM). An experimental design methodology, namely "two-level factorial design," was used to evaluate the influence of the amounts of TEOS, ammonia, and gelation time on the tensile modulus, tensile strength, and tear strength of the vulcanizate...

2008-01-01

41

Separation Phenomenon Occurring during the Charpy Impact Test of API X80 Pipeline Steels  

Science.gov (United States)

A separation phenomenon occurring during the Charpy impact test of API X80 pipeline steels was investigated in the present study. A detailed microstructural analysis of fractured impact specimens showed that the band structure of bainite elongated along the rolling direction worked as prior initiation sites for separations, and that the number and length of the separations increased with the increasing volume fraction of bainite. In the steels having high work hardenability, tearing-shaped separations were found because the hammer-impacted region was seriously hardened during the impact test, which led to the reduction in the impact toughness. As the test temperature decreased, the tendency toward separations increased, but separations were not found when the cleavage fracture prevailed at very low temperatures. These findings suggested that the formation of bainite and secondary phases should be minimized for preventing or minimizing separations, because ...

2009-10-01

42

Premature Failure of a Riata Defibrillator Lead Without Impedance Change or Inappropriate Sensing: A Case Report and Review of the Literature  

British Library Electronic Table of Contents (United Kingdom)

Premature Failure of a Riata Defibrillator Lead. A 63-year-old woman with a St. Jude Medical Riata 1570 right ventricular lead complained of intermittent hiccups 2 months after implant. Interrogation revealed elevated pacing threshold and diaphragmatic stimulation. Pacing and shock lead impedances remained stable. No inappropriate sensing was noted. Fluoroscopic examination of the lead revealed a thin radio-opaque wire seen between the 2 defibrillator coils away from the main body of the lead. After extraction, a tear in the insulation of the lead was noted allowing the inner wire to protrude. This case illustrates a novel mechanism of insulation failure without inappropriate sensing or impedance change.-(J Cardiovasc Electrophysiol, Vol. 22, pp. 1070-1072, September 2011)

2011-01-01

43

Pet keeping and dampness in the dwelling: associations with airway infections, symptoms, and physiological signs from the ocular and nasal mucosa:  

British Library Electronic Table of Contents (United Kingdom)

Abstract The aim was to utilize data from a study of occupational indoor environments to analyze symptoms and physiological signs in relation to the home environment. A medical investigation was performed at the workplace among university staff (n = 173) from four university buildings in Bergen, in March 2004. Tear film break up time (BUT) was measured by two methods. Nasal patency was measured by acoustic rhinometry. Nasal lavage fluid analysis (NAL) included eosinophilic cationic protein (ECP); myeloperoxidase (MPO), lysozyme and albumin. Atopy was assessed by total serum IgE and specific IgE (Phadiatop). Totally 21%, 21%, 18%, 11%, and 27% had weekly ocular, nasal, facial dermal symptoms, headache and tiredness, respectively, 15% had a damp dwelling, and 20% had a cat or dog. Multiple l...

2007-01-01

44

Magnetospheric particle acceleration and X-ray emission of pulsars  

CERN Document Server

The available data on isolated X-ray pulsars, their wind nebulae, and the supernova remnants which are connected to some of these sources are analyzed. It is shown that electric fields of neutron stars tear off charged particles from the surface of neutron star and trigger the acceleration of particles. The charged particles are accelerated mainly in the field of magneto-dipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magneto-dipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.

2007-01-01

45

Gun requirements to achieve high field spheromaks  

Energy Technology Data Exchange (ETDEWEB)

It is shown that a gun similar to that in the SSPX could demonstrate the high fields required for Pulsed Spheromak reactors merely by prolonging the pulse. Important considerations are choosing the voltage to exceed ohmic losses; designing the gun to avoid wasteful short-circuiting of current within the gun; and the injection efficiency factor, f, determined by the ''sag'' in the profile of {lambda} = {mu}{sub o}j/B. Typically f = 0.75 in experiments, giving an overall efficiency > 50 % if short-circuiting is avoided. Theoretical transport models agree qualitatively with the need for a finite gradient in h to pump in helicity by current-driven tearing modes and suggest that pressure-driven resistive modes would not compete with current-driven modes during a buildup to ohmic ignition.

1999-03-04

46

Effect of treatment of Bis(3-triethoxysilyl propyl)tetrasulfane on physical property of in situ sodium activated and organomodified bentonite clay - SBR rubber nanocomposite  

British Library Electronic Table of Contents (United Kingdom)

This study describes the effect of treatment of Bis(3-triethoxysilyl propyl)tetrasulfane (silane coupling agent, Si69, TESPT) on in situ sodium activated, organo modified bentonite clay - styrene butadiene rubber (SBR) nanocomposite. transmission electron microscopy and Wide angle X-ray diffraction indicated the intercalation as well as partial exfoliation in both the organoclay and silane treated organoclay compound. It was found that about 5% of silane with respect to clay was the optimum dose for the treatment. Around 15% improvement in tensile and tear strength was observed due to silane treatment. Silane treated organoclay exhibited substantial improvement of the fatigue life, compression set, and rebound property. A detailed study of physical property was carried out. A comparison wi...

2010-01-01

47

Crack tip opening angle measurement through a girth weld in an X100 steel pipeline section  

British Library Electronic Table of Contents (United Kingdom)

ABSTRACT Crack tip opening angle (CTOA) is becoming one of the most accepted methods for characterizing fully plastic fracture. It provides a measure of the resistance to fracture for a material in cases where there is a large degree of stable-tearing crack extension during the fracture process. Our current pipeline research uses the CTOA test as an alternative, or addition, to the CTOD (crack tip opening displacement) and the fracture energy characterization provided by the J-integral approach. A test technique was developed for measurement of CTOA that uses a modified double cantilever beam (MDCB) specimen. A digital camera and image analysis software were used to record the progression of the crack tip and to estimate the CTOA. In this article, CTOA data on crack growth orientations per...

2008-01-01

48

Acceleration of particles in pulsar magnetosphere and the X-ray radiation  

CERN Document Server

The available data of single X-ray pulsars, their wind nebulae, and the SNRs which are connected to some of these sources are analysed. It is shown that electric field intensity of neutron stars tears off charged particles from the surface of neutron star and triggers the acceleration of particles. The charged particles are accelerated mainly in the field of magnetodipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magnetodipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.

2004-01-01

49

National NIF Diagnostic Program Fiscal Year 2002 Second Quarter Report  

Energy Technology Data Exchange (ETDEWEB)

Since October 2001 the development of the facility diagnostics for NIF has been funded by the NIF Director through the National NIF Diagnostic Program (NNDP). The current emphasis of the NNDP is on diagnostics for the early NIF quad scheduled to be available for experiment commissioning in FY03. During the past six months the NNDP has set in place processes for funding diagnostics, developing requirements for diagnostics, design reviews and monthly status reporting. Those processes are described in an interim management plan for diagnostics (''National NIF Diagnostic Program Interim Plan'', NIF-0081315, April 2002) and a draft Program Execution Plan (''Program Execution Plan for the National NlF Diagnostic Program'', NIF-0072083, October 2001) and ...

2002-04-01

50

Validity of Cardiac Markers as Diagnostic and Prognostic Indicators of Complications in Patients undergoing Percutaneous Coronary Intervention  

UK PubMed Central (United Kingdom)

ObjectivesThe aim of this study was to assess the diagnostic and prognostic value of heart-type fatty acid-binding protein (H-FABP) in elective percutaneous coronary intervention...Full Text Available

2010-04-01

51

Simple fractal method of assessment of histological images for application in medical diagnostics  

UK PubMed Central (United Kingdom)

We propose new method of assessment of histological images for medical diagnostics. 2-D image is preprocessed to form 1-D landscapes or 1-D signature of the image contour and then their complexity is...Full Text Available

52

SNQ for medical research  

Energy Technology Data Exchange (ETDEWEB)

The planned spallation source can be of considerable significance for biomedical basic research and for clinically relevant diagnostic and therapeutic applications. The following gives a brief description and explanations for its possible use in clinical medicine: I. Treatment of Malignant Tumors II. Production of Isotopes for Biochemical Investigations in Living Organisms for Diagnostic Purposes.

1984-12-01

53

Reduction of anti-malarial consumption after rapid diagnostic tests implementation in Dar es Salaam: a before-after and cluster randomized controlled study  

UK PubMed Central (United Kingdom)

BackgroundPresumptive treatment of all febrile patients with anti-malarials leads to massive over-treatment. The aim was to assess the effect of implementing malaria rapid diagnostic...Full Text Available

54

Perceived association between diagnostic and non-diagnostic cues of women's sexual interest: General Recognition Theory predictors of risk for sexual coercion  

UK PubMed Central (United Kingdom)

Young men's errors in sexual perception have been linked to sexual coercion. The current investigation sought to explicate the perceptual and decisional sources of these social perception errors,...Full Text Available

2010-01-01

55

Factors underlying diagnostic delay in tuberculosis patients in a rural area in Tanzania: a qualitative approach  

UK PubMed Central (United Kingdom)

BackgroundDiagnostic delay in patients with tuberculosis (TB) leads to ongoing TB transmission, higher mortality rates and increased patient and government health expenditure. Qualitative...Full Text Available

2010-12-01

56

Diagnostic comparison of malaria infection in peripheral blood, placental blood and placental biopsies in Cameroonian parturient women  

UK PubMed Central (United Kingdom)

BackgroundIn sub-Saharan Africa, Plasmodium falciparum malaria in pregnancy presents an enormous diagnostic challenge. The epidemiological and clinical relevance...Full Text Available

57

Diagnostic Performance of Computed Tomography Colonography in Symptomatic Patients and in Patients with Increased Risk for Colorectal Disease  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate the diagnostic performance (colorectal lesions) of computed tomography (CT) colonography in 111 patients, a majority of whom were at high risk for colorectal neoplasia. Material and Methods: After bowel preparation, CT colonography was performed, immediately followed by conventional colonoscopy. The diagnostic performance of CT colonography was analyzed relative to lesion size, histological diagnosis, and diagnostic certainty. Results: The sensitivity of CT colonography increased with lesion size (P<0.001), and was 91% (21/23) for lesions > or = 10 mm. All 10 carcinomas and 86% (19/22) of adenomas > or = 5 mm were detected. Unconfirmed or false-positive CT findings were generally small and/or reported with low diagnostic certainty. The specificity of CT colonography would be 45% (30/66; 95% CI 34% to 57%) if patients with findings of any size and any ...

2006-11-15

58

Biological, Life Course, and Cross-Cultural Studies All point Toward the Value of Dimensional and Developmental Ratings in the Classification of Psychosis  

UK PubMed Central (United Kingdom)

The diagnostic criteria for schizophrenia in the fourth edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-IV1)...Full Text Available

2007-07-01

59

Assessment of the value of various tomography modalities for diagnostic evaluation of the female genital system  

International Nuclear Information System (INIS)

The comprehensive survey explains the indications and the specific value of the modern tomographic modalities with respect to the various diagnostic issues. Numerous reproductions of CT, MRI, US scans illustrate the aspects discussed. (orig./CB)

2001-09-01

60

Age-Stratified Bayesian Analysis To Estimate Sensitivity and Specificity of Four Diagnostic Tests for Detection of Cryptosporidium Oocysts in Neonatal Calves?  

UK PubMed Central (United Kingdom)

There is no gold standard diagnostic test for the detection of bovine cryptosporidiosis. Infection is usually highest in 2-week-old calves, and these calves also excrete high numbers of oocysts. These...Full Text Available

2011-01-01

61

A simple nomogram for sample size for estimating sensitivity and specificity of medical tests  

UK PubMed Central (United Kingdom)

Sensitivity and specificity measure inherent validity of a diagnostic test against a gold standard. Researchers develop new diagnostic methods to reduce the cost, risk, invasiveness, and time. Adequate...Full Text Available

2010-11-01

65

Plasma diagnostics in the optical and X-ray regions on the plasma focus device PF-4 (TULIP)  

International Nuclear Information System (INIS)

... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,

2006-09-11

66

Investigating Models of Social Development Using a ...  

Science.gov (United States)

... taker', Adaptive Behavior. In submission. Behavioral Disorders: Diagnostic Criteria for Re- Breazeal (Ferrell), C. (1998), A Motivational System for ...

2011-05-13

67

Methods and results of a representative analysis of the radiation exposure of the population by diagnostic radiology  

International Nuclear Information System (INIS)

From the frequency of diagnostic radiologic examinations and their radiation dose delivered to the population the risk of cancer induction and genetic damage is calculated on the basis of the risk factors given by the ICRP. Thus 0.38 % and 3 % of the total mortality for cancer and leukemia, resp., can be attributed to X-ray diagnostics. Chest examinations alone result in 0.07-0.7 damages per 100,000 persons depending on the imaging technique applied. (author).

1984-01-01

68

Target Diagnostic Instrument-Based Controls Framework for the National Ignition Facility  

Energy Technology Data Exchange (ETDEWEB)

NIF target diagnostics are being developed to observe and measure the extreme physics of targets irradiated by the 192-beam laser. The response time of target materials can be on the order of 100ps--the time it takes light to travel 3 cm--temperatures more than 100 times hotter than the surface of the sun, and pressures that exceed 109 atmospheres. Optical and x-ray diagnostics were developed and fielded to observe and record the results of the first 4-beam experiments at NIF. Hard and soft x-ray spectra were measured, and time-integrated and gated x-ray images of hydrodynamics experiments were recorded. Optical diagnostics recorded backscatter from the target, and VISAR laser velocimetry measurements were taken of laser-shocked target surfaces. Additional diagnostics are being developed and commissioned to observe and diagnose ignition implosions, including various neutron and activation ...

2007-05-07

69

MRI in definition of bleeding source, lesion pattern and therapy in haemarthros of the knee; Die MRT beim Haemarthros des Kniegelenks: Bestimmung von Blutungsursachen, Verletzungsmustern und Therapie  

Energy Technology Data Exchange (ETDEWEB)

Patients with haemarthros of the knee were examined by MRI and arthroscopy to identify the bleeding source and to determine surgical or conservative therapy. A prospective study was performed on 120 patients who underwent MRI and arthroscopy, point lesions and bleeding sources were documented separately on a standardised form. Arthroscopy demonstrated a ruptured anterior cruciate ligament in 86%, meniscal tears in 55%, disruption of collateral ligaments in 17%, osteochondral lesions in 5% and tears of capsule or plicae in 13%. Disruption of cruciate ligaments caused haemorrhage in all but three cases. In contrast, only meniscal tears located very adjacent to the meniscal basement had bled. Those types of osteochondral lesions caused haemorrhage characterised on MRI by destruction of the subchondral plate and overlying cartilage. Severe lesions of the knee were diagnosed by MRI in 71% to 100%, slight lesions in 13% to 40% of ...

1996-09-01

70

Hydrogen-plasticity interactions in pearlitic steel: a fractographic and numerical study  

Energy Technology Data Exchange (ETDEWEB)

A fractographic and numerical approach is presented to analyze hydrogen-plasticity interactions in pearlitic steel and to elucidate the main hydrogen transport mechanism in this material under triaxial stress states produced by notches. Fractographic analysis showed that the microdamage produced by the hydrogen was clearly detectable by scanning electron microscopy (SEM), through a specific microscopic topography associated with hydrogen effects (tearing topography surface or TTS). Numerical computations obtained by using an elastic-plastic finite element program gave the progressive spreading of the plastic zone, closely associated with the movement of dislocations. In the majority of cases, the plastic zone (PZ) clearly exceeds the hydrogen affected region (TTS) and has no relation with it. In some tests, however, the hydrogen-induced micro-damage surpasses the only region in which there is dislocation movement, and in this case the net macroscopic transport of ...

1996-11-30

71

Effects of gamma irradiation on the physical properties of laminated packaging materials. 2. polypropylene-polypropylene, polypropylene-polyethylene, and polyester-polyethylene  

International Nuclear Information System (INIS)

This experiment was done to determine the effects of irradiation on the physical properties of three kinds of laminated packaging materials, i.e. polypropylene-polypropylene, polypropylene-polyethylene, polyester-polyethylene. Observations were made on pinhole production, leakage, oil resistance, resistance against insect penetration, colour, odour tensile strength, elongation at break, seal strength and tear resistance. The samples were irradiated with doses of 0, 5 and 10 kGy, then stored at room temperature and examined after 0, 3, 6 and 12 months of storage. The results showed that irradiation doses up to 10 kGy, as well as storage up to 12 months, did not create pinholes, or leakage in pouches prepared from laminated films. The resistance of the films to oil and insect penetration, the colour, and the odour were also unchanged. Both irradiation and storage treatments had a significant effect on physical properties of the laminated films. In general, the ...

72

Determination of Inter-Phase Line Tension in Langmuir Films  

CERN Document Server

A Langmuir film is a molecularly thin film on the surface of a fluid; we study the evolution of a Langmuir film with two co-existing fluid phases driven by an inter-phase line tension and damped by the viscous drag of the underlying subfluid. Experimentally, we study an 8CB Langmuir film via digitally-imaged Brewster Angle Microscopy (BAM) in a four-roll mill setup which applies a transient strain and images the response. When a compact domain is stretched by the imposed strain, it first assumes a bola shape with two tear-drop shaped reservoirs connected by a thin tether which then slowly relaxes to a circular domain which minimizes the interfacial energy of the system. We process the digital images of the experiment to extract the domain shapes. We then use one of these shapes as an initial condition for the numerical solution of a boundary-integral model of the underlying hydrodynamics and compare the subsequent images of the experiment to the numerical ...

2007-01-01

73

A personal computer based system to evaluate J-integral by a single specimen unloading compliance method: Pt. 2  

International Nuclear Information System (INIS)

A personal computer based single specimen unloading technique has been demonstrated using a nuclear grade pressure vessel material, A533B Class I steel, and an #alpha#-#beta# titanium alloy, CORONA-5. Experimental parameters investigated in the case of steel include the effect of test temperature, loading rate and neutron irradiation. Results revealed the effect of dynamic strain aging (DSA) as a drop in the critical crack initiation fracture toughness (Jsub(q)); the minimum in Jsub(q) shifts to higher temperatures at higher test speeds as predicted from DSA models. In CORONA-5, the effects of microstructure and heat treatment for two different sizes of equiaxed #alpha# morphology in a #beta#-matrix heat treated to different yield strengths were investigated. It is found that the observed higher values of Jsub(q) and tearing modulus result from a greater tortuosity of the crack path and ease of crack blunting. The largest increase in Jsub(q) occurred in fine ...

74

Radiation hardening problems of diagnostic components for International Thermonuclear Experimental Reactor (ITER)  

International Nuclear Information System (INIS)

The Joint Work Session of the ITER CDA (Conceptual Design Activities) by four parties, (eg. Japan, USA, USSR and EC), which has continued during 3 years from May 1988 to December 1990 was completed successfully. During the CDA, overall diagnostic systems for the next generation machine was performed for the first time and the principal tasks of Diagnostic research and development (R and D) are identified. In this paper, radiation hardening problems, which should be solved for the period 1991 through 1996 of the ITER EDA (Engineering Design Activities), are described. (author).

75

New developments in the surveillance and diagnostics technology for vibration, structure-borne sound and leakage monitoring systems  

International Nuclear Information System (INIS)

Monitoring and diagnostic systems are of main importance for a safe and efficient operation of nuclear power plants. The author describes new developments with respect to vibration monitoring with a functional extension in the time domain for den secondary circuit, the development of a local system for the surveillance of rotating machines, the structure-borne sound monitoring with improvement of event analysis, esp. the loose part locating, leakage monitoring with a complete system for humidity measurement, and the development of a common platform for all monitoring and diagnostic systems, that allows an efficient access for comparison and cross references.

76

Coherent Synchrotron Radiation as a Diagnostic Tool for the LCLS Longitudinal Feedback System  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL). To ensure the vitality of FEL lasing, a longitudinal feedback system is required together with other diagnostics. In this paper, we study the possibility of using Coherent Synchrotron Radiation (CSR) from the chicane as a diagnostic tool for bunch length feedback. Studies show that CSR is a good candidate, even for a non-Gaussian, double-horn longitudinal charge distribution as in the LCLS. We further check the possibility for detecting possible microbunching.

2005-06-15

77

Cerebral and meningeal manifestations of AIDS: Sensitivity of CT and T sub 2 -weighted MR (129 patients). Zerebrale und meningeale Manifestation des AIDS: Sensitivitaet von CT und T sub 2 -gewichteter MRT (129 Patienten)  

Energy Technology Data Exchange (ETDEWEB)

We studied 129 AIDS patients with suspected or proved intracranial manifestations of the disease. The purpose of this study was to compare the diagnostic sensitivity of unenhanced and contrast enhanced CT and unenhanced T{sub 2}-weighted MR. Thus, in 20% of our patients MR but not CT was diagnostic. In another 20% MR provided additional diagnostic information. In conclusion, MR is recommended as the imaging modality of choice in AIDS patients with non-conclusive cranial CT. (orig./GDG).

1990-09-01

78

A somatic dose index for diagnostic radiology  

International Nuclear Information System (INIS)

Irradiation of the human body in diagnostic X-ray procedures results in different absorbed doses in the various body organs. A somatic dose index in formulated by applying the relative sensitivity of the human to each of the most important somatic effects and utilizing the absorbed dose in the affected organs. This quantity is used to convey a cumulative somatic impact and is computed for common radiographic views in diagnostic radiology as a function of beam quality for a nominal IR entrance exposure. Using typical X-ray beam qualities and exposures, the frequency of the various radiographic views that make up an examination and the frequencies of the various examinations in the national population, illustrative examples of the application of the somatic dose index are presented. (author).

1978-01-01

79

Two-year diagnostic stability in early-onset first-episode psychosis  

British Library Electronic Table of Contents (United Kingdom)

Background:- Only one study has used a prospective method to analyze the diagnostic stability of first psychotic episodes in children and adolescents. The Child and Adolescent First-Episode Psychosis Study (CAFEPS) is a 2-year, prospective longitudinal study of early-onset first episodes of psychosis (EO-FEP). Aim:- To describe diagnostic stability and the variables related to diagnostic changes. Methods:- Participants were 83 patients (aged 9-17-years) with an EO-FEP consecutively attended. They were assessed with a structured interview (Kiddie-Schedule for Affective Disorders and Schizophrenia, Present and Lifetime version) and clinical scales at baseline and after 2-years. Results:- The global consistency for all diagnoses was 63.9%. The small group of bipolar disorder had high stabilit...

2011-01-01

80

Targeting a Ruthenium Complex to the Nucleus with Short Peptides  

UK PubMed Central (United Kingdom)

In an effort to develop octahedral metal complexes as chemotherapeutic and diagnostic agents targeted to DNA, it is critical to optimize the properties of their cellular uptake. Appending d-octaarginine...Full Text Available

2010-05-15

81

Studies on the diagnostic accuracy of lymphography  

International Nuclear Information System (INIS)

Contradictory reports in the literature on the reliability of lymphography stimulated the authors to test the diagnostic accuracy, employing methods which are approximately analogous to practice, using carcinoma of the cervix as the model on which the study was carried out. Using 21 observers it was found that there was no correlation between their experience and on-target accuracy of the diagnosis. Good observers obtained an accuracy of 85% with good proportions between sensitivity in the recognition of detail, specificity and readiness to arrive at a decision on the basis of discriminatory ability. With the help of the concept of the ROC curves, the position taken up by the observers in respect of diagnostic decisions, and a complex manner of assessing the various characteristic factors determining diagnostic accuracy, are demonstrated. This form of test, which permits manipulation of different variants of diagnosis, is ...

82

Reduction of diagnostic expense in space-occupying processes of the pancreas by fine-needle biopsy under computerized tomography (CT)  

International Nuclear Information System (INIS)

Comparative analysis of diagnostic accuracy (dignity determination) in CT-guided fine-needle biopsy (141 patients), CT (141), ultrasonography (89), angiography (50), and cholegraphy (ERCP, 55), was carried out in suspected space-occupying lesions of the pancreas. With accuracy of 86%, sensitivity of 37% and specificity of 92% fine-needle biopsy was superior to imaging procedures. Additional comparison of the results concerning the patients and Roc curves confirm the statements. For reduction of the number of imaging investigations a diagnostic algorithm is proposed, that starts with diagnostic CT and subsequent fine-needle biopsy controlled by CT. This would result in a more adequate use of angiography and ERCP and in the elimination of ultrasonography. (author).

83

Real-Time Diagnostics for a Reusable Rocket Engine - NASA ...  

Science.gov (United States)

of the Intelligent Control System (ICS) for reusable rocket engines. .... the incoming measurements with corresponding estimates, a sensor failure can be ...

84

Radiation risk in computerized tomography (CT)  

Energy Technology Data Exchange (ETDEWEB)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional ...

1984-01-01

85

Radiation risk in computerized tomography (CT)  

International Nuclear Information System (INIS)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional ...

1984-01-01

86

Radiation risk in computerized tomography (CT)  

International Nuclear Information System (INIS)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional ...

87

Pubs.GISS: 1977 Publications  

Science.gov (United States)

Astron. J., 82, 890-901, doi:10.1086/112143. Ghil, M., B. Shkoller, and V. Yangarber, 1977: A balanced diagnostic system compatible with a barotropic prognostic model....

2011-09-17

88

Microscopic-Observation Drug-Susceptibility Assay for the Diagnosis of TB  

UK PubMed Central (United Kingdom)

BACKGROUNDNew diagnostic tools are urgently needed to interrupt the transmission of tuberculosis and multidrug-resistant tuberculosis. Rapid,...Full Text Available

2006-10-12

90

Humoral BMP-2 is Sufficient for Inducing Breast Cancer Microcalcification  

UK PubMed Central (United Kingdom)

Microcalcifications are an important diagnostic marker for breast cancer on mammograms, yet the mechanism of their formation is poorly understood. Indeed, there is presently no short-latency,...Full Text Available

2008-01-01

91

Evaluation of Peripheral Atherosclerosis: A Comparative Analysis of Angiography and Intravascular Ultrasound  

UK PubMed Central (United Kingdom)

ObjectiveAngiography remains a critical component for diagnostic imaging and therapeutic intervention in peripheral arterial disease (PAD). The goal of this study...Full Text Available

2010-04-01

92

Diagnostics of Radionuclides Effects Results  

International Science & Technology Center (ISTC)

Development of New Methods and Means of Assessing of Consequences of Radionuclide and Heavy Metal Salt Effect, Criteria of Forecasting Physiological State and Productivity of the Farm Animals under Conditions of Ecological Pollution of Environment

93

Diagnostic imaging in pregraduate integrated curricula; Radiologie in einem praegraduellen problembasiert-integrierten Medizincurriculum  

Energy Technology Data Exchange (ETDEWEB)

Pregraduate medical curricula are currently undergoing a reform process that is moving away from a traditional discipline-related structure and towards problem-based integrated forms of teaching. Imaging sciences, with their inherently technical advances, are specifically influenced by the effects of paradigm shifts in medical education. The teaching of diagnostic radiology should be based on the definition of three core competencies: in vivo visualization of normal and abnormal morphology and function, diagnostic reasoning, and interventional treatment. On the basis of these goals, adequate teaching methods and e-learning tools should be implemented by focusing on case-based teaching. Teaching materials used in the fields of normal anatomy, pathology, and clinical diagnosis may help diagnostic radiology to play a central role in modern pregraduate curricula. (orig.)

2007-11-15

94

Diagnostic Value of C-reactive Protein in Complicated Appendicitis  

UK PubMed Central (United Kingdom)

PurposeEarly detection of appendicitis has increased due to development of computed tomography and ultrasonography, yet we are frequently meeting complicated appendicitis, including...Full Text Available

2011-06-01

96

Comparison of methods to determine accurate dose calibrator activity measurements  

UK PubMed Central (United Kingdom)

BackgroundIn nuclear medicine, liquid radiopharmaceuticals for diagnostic or therapeutic purposes are administered to patients by using various types of syringes with different volumes....Full Text Available

97

Cardiac Enzymes, Renal Failure and Renal Transplantation  

UK PubMed Central (United Kingdom)

Diagnostic accuracy of the currently available serum markers of cardiac injury, such as myoglobin, creatine kinase and its myocardial isoform, are altered in patients with renal failure. It is shown...Full Text Available

2006-03-01

98

Anxiety and Cancer Treatment: Response to Stressful Radiotherapy  

UK PubMed Central (United Kingdom)

Previous research with individuals undergoing surgery or diagnostic procedures provided a conceptual framework for analysis of radiation therapy, a common form of cancer treatment. The present...Full Text Available

1984-01-01

99

A Dose- and Time-Controllable Syngeneic Animal Model of Breast Cancer Microcalcification  

UK PubMed Central (United Kingdom)

IntroductionThe development of novel diagnostic agents for the detection of breast cancer microcalcifications requires a reliable animal model. Based on previous...Full Text Available

2010-07-01

100

Trial of using computer tomography in the diagnosis of mediastinal diseases in children  

Energy Technology Data Exchange (ETDEWEB)

In 15 children (in age 2 weeks - 15 years) the computer tomography beside radiological examination was done because of mediastinal diseases. In all cases the computer tomography was valuable. In 4 cases obtained results have changed diagnostic conclusions. The examples are described showing the usefulness of the computer tomography as supplementary diagnostic method in mediastinal diseases in children.

1981-01-01

101

Survey of radiation doses to patients from the diagnostic use of X-rays  

International Nuclear Information System (INIS)

The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).

1977-06-01

102

Spreader Design for FERMI@Elettra Free Electron Laser  

Energy Technology Data Exchange (ETDEWEB)

In this note we describe a conceptual design of a part ofthe electron beam delivery system for FERMI@Elettra free electron laser(FEL) located between the end of the linac and the entrance to the FEL.This part includes the emittance diagnostic section, the electron beamswitchyard for two FELs called spreader and matching sections. The designmeets various constrains imposed by the existing and planned buildingboundaries, desire for utilization of existing equipment and demands forvarious diagnostic instruments.

2007-01-18

103

Researches on gear fault diagnostic techniques  

Science.gov (United States)

Attention is given to recent research on gear fault diagnostic techniques. A mathematic model for vibration signals of defective gears is presented. Novel methods of gear fault diagnosis, such as zoom complex envelope analysis, wideband demodulation techniques, bispectrum analysis, correlation spectrum analysis, and maximum entropy spectrum analysis, are demonstrated. The wide-band demodulation technique is found to exhibit a high SNR. Bispectrum and correlation spectrum are excellent for some mechanical fault forms.

1992-10-01

104

Radiation doses in adults and children in standardized diagnostic radiology  

International Nuclear Information System (INIS)

For comparison of radiation exposure and risk in different diagnostic procedures for adults and children dose measurements and calculations of organs with special risk were carried out. Parameters of image formation influencing image quality as well as of exposure concerning infants and children are recorded and discussed as to radiation exposure and protection. Conclusions are drawn with respect to systems of image formation and to standards of examination and quality assurance.

1987-01-01

105

Process in Plasma Research at IPJ and IPPLM, POLAND  

International Nuclear Information System (INIS)

The most important results of theoretical and experimental studies of plasmas, which have been achieved at the IPJ in Swierk and IPPLM in Warsaw recently, are presented. Studies of physical phenomena in PF discharges, development of diagnostic techniques and research on new plasma technologies, as performed at IPJ, have been summarized. Studies of dense magnetized plasmas, investigation of physics and applications of laser-produced plasmas; and research on the development of advanced diagnostic techniques for the EUROATOM fusion program, as performed at IPPLM, are also described.

2006-01-01

106

Magnetic diagnostic of beta poloidal and internal inductance of plasma in the TCA/BR tokamak  

Energy Technology Data Exchange (ETDEWEB)

This report continues the studies of simplified methods, of magnetic diagnostics in application to TCA/BR tokamak. Here we study the accuracy of known formula for {beta}{sub 1} + l{sub 1}/2 determination from the poloidal magnetic field asymmetry. Errors of the diamagnetic measurements due to vibrations of the vacuum vessel are also considered. (author). 3 refs., 1 fig., 1 tab.

1996-12-31

107

Evaluation of two-beam spectroscopy as a plasma diagnostic  

Energy Technology Data Exchange (ETDEWEB)

A two-beam spectroscopy (TBS) system is evaluated theoretically and experimentally. This new spectroscopic technique uses correlations between components of emitted light separated by a small difference in angle of propagation. It is thus a non-perturbing plasma diagnostic which is shown to provide local (as opposed to line-of-sight averaged) information about fluctuations in the density of light sources within a plasma - information not obtainable by the usual spectroscopic methods. The present design is an improvement on earlier systems proposed in a thesis by Rostler.

1980-04-01

108

Evaluation of Sanofi Diagnostics Pasteur Chlamydia Microplate EIA shortened assay and comparison with cell culture and Syva Chlamydia MicroTrak II EIA in high- and low-risk populations.  

UK PubMed Central (United Kingdom)

Seven hundred thirty-two female urogenital samples were collected for Chlamydia trachomatis testing by both the Sanofi Diagnostics Pasteur (Chaska, Minn.) Chlamydia Microplate EIA by the shortened protocol...Full Text Available

1995-11-01

109

Electron beam and high-speed optical diagnostics for the Los Alamos HIBAF (High Brightness Accelerator FEL) Facility  

Energy Technology Data Exchange (ETDEWEB)

Characterization of the electron beam's properties will be a major task after the upgrade of the Los Alamos Free-Electron Laser (FEL) Facility with a photoelectric injector (PEI) and increased acceleration capability to 40 MeV. Adjustments to the previous diagnostics package that address the lower beam emittance, higher energy, and wakefield source reduction issues will be discussed. 6 refs., 8 figs., 1 tab.

1989-01-01

110

Diagnostic imaging of the acutely injured patient  

Energy Technology Data Exchange (ETDEWEB)

This book provides an analysis of pathophysiologic concepts of trauma and reviews the effectiveness of the available imaging modalities in acute trauma of various organ system. Topics covered are chest injuries; abdominal trauma; fractures of long bones; the foot and ankle; the knee; hand and wrist; the elbow; the shoulder; the pelvis hips; the spine; the skull and facial trauma and the clinical assessment of multiple injuries patients. Comparative evaluation of diagnostic techniques of radiography is discussed. Normal anatomy and bone fractures along with soft-tissue injuries are described.

1985-01-01

111

DIPAC 2005 7. European workshop on beam diagnostics and instrumentation for particle accelerators  

Energy Technology Data Exchange (ETDEWEB)

Accelerators can not be improved without the development of adequate beam instruments and diagnostic tools. This year this statement is particularly right: a lot of contributions are dedicated to beam monitoring and to the design of new beam monitors based on original technologies. This document gathers about 100 contributions.

2005-07-01

112

Computer tomography used in tumour diagnosis in children  

Energy Technology Data Exchange (ETDEWEB)

Computer tomography used in the diagnosis of tumours is described in the light of particularly great diagnostic difficulties in children. Computer tomography was applied in 12 cases. A high diagnostic value of this method was demonstrated, which makes possible a more accurate diagnosis of the position of the tumour, its size, and expanding tendency. The possibility of estimating healthy tissues and organs, and those with pathological changes on the basis of differences in their density with a detection threshold at 0.5% density difference facilitates not infrequently preoperative diagnosis raising the value of the method.

1981-01-01

113

Baryon-strangeness correlations: a diagnostic of stronglyinteracting matter  

Energy Technology Data Exchange (ETDEWEB)

The correlation between baryon number and strangeness elucidates the nature of strongly interacting matter. This diagnostic can be extracted theoretically from lattice QCD calculations and experimentally from event-by-event fluctuations. The analysis of present lattice results above the critical temperature severely limits the presence of q{bar q} bound states, thus supporting a picture of independent (quasi)quarks. Details may be found in [1].

2005-10-07

114

Diagnostic capability of digital radiography of the chest using scanning laser stimulated luminescence  

Energy Technology Data Exchange (ETDEWEB)

Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was evaluated by 19 radiologists, using ROC curve analysis. FCR and ...

1989-02-01

115

Diagnostic capability of digital radiography of the chest using scanning laser stimulated luminescence  

International Nuclear Information System (INIS)

Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was evaluated by 19 radiologists, using ROC curve analysis. FCR and ...

1989-01-01

116

CT-guided percutaneous core biopsies of pulmonary lesions: Diagnostic accuracy, complications and therapeutic impact  

International Nuclear Information System (INIS)

To evaluate the diagnostic accuracy, complications, and therapeutic impact of CT-guided percutaneous core biopsies of pulmonary lesions. Material and methods: Seventy-nine patients underwent diagnostic CT-guided percutaneous core biopsies of pulmonary lesions between July 1995 and March 1999. Evaluation included corresponding clinical data, pathologic results, and therapeutic consequences. Results: There were 29 benign and 50 malignant lesions. Percutaneous core biopsy had an overall diagnostic accuracy of 95%. For malignant lesions, core biopsy was positive in 48 patients (sensitivity 96%), and for benign lesions, in 27 (sensitivity 93%). There were no false-positive findings. Pneumothoraces were observed in 19 patients (24%) and 4 of them required a chest drain (5%). There were no hematothoraces or major bleeding complications; however, postinterventional local hemorrhages were observed in 23 patients (29%). No hemoptysis ...

2001-03-01

117

The electron cyclotron absorption diagnostic for the JET pumped divertor plasma  

International Nuclear Information System (INIS)

We present the design of a diagnostic system to measure electron cyclotron absorption at the second harmonic E-mode resonance in the JET pumped divertor plasma. The diagnostic will measure transmission as a function of frequency along one or more sightlines from which the spatial profile of the n_eT_e product will be deduced. The divertor is briefly described, and the electron cyclotron resonance physics relevant to this measurement is reviewed. The problems of measuring transmission using an oversized transmission system are discussed and the chosen measurement technique, a swept frequency interferometer using a coherent radiation source, is described. A prototype of the instrument has been assembled to test the measurement technique. Some data demonstrating the instrument's characteristics are presented. The nonresonant losses, which may affect the interpretation of the measurement, are also discussed. (orig.).

1993-03-01

118

Neutron imaging system for neutron tomography, radiography, and beam diagnostics  

Energy Technology Data Exchange (ETDEWEB)

A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.

1995-12-31

119

Traumatic extremity arterial injury in children: Epidemiology, diagnostics, treatment and prognostic value of Mangled Extremity Severity Score  

UK PubMed Central (United Kingdom)

BackgroundTraumatic paediatric arterial injuries are a great challenge due to low incidence and specific characteristics of paediatric anatomy and physiology. The aim of the present...Full Text Available

120

The treatment of mycosis fungoides and related conditions with particular emphasis on electron therapy.  

UK PubMed Central (United Kingdom)

The difficulties created by the lack of generally accepted views on classification, diagnostic criteria and natural history of the cutaneous lymphomata are discussed. Only the lymphomata which remain...Full Text Available

1975-03-01

121

The sensitivity of real-time PCR amplification targeting invasive Salmonella serovars in biological specimens  

UK PubMed Central (United Kingdom)

BackgroundPCR amplification for the detection of pathogens in biological material is generally considered a rapid and informative diagnostic technique. Invasive Salmonella...Full Text Available

122

The concept of mental disorder: diagnostic implications of the harmful dysfunction analysis  

UK PubMed Central (United Kingdom)

What do we mean when we say that a mental condition is a medical disorder rather than a normal form of human suffering or a problem in living? The status of psychiatry as a medical discipline depends...Full Text Available

2007-10-01

123

The Effect of Age on the Gingival Crevicular Fluid Composition During Experimental Gingivitis. A Pilot Study  

UK PubMed Central (United Kingdom)

Background:Cytokines have been proposed as potentially useful diagnostic or prognostic markers of periodontal inflammation related alterations during the experimental gingivitis...Full Text Available

124

Stereocomplexed PLA-PEG Nanoparticles with Dual-Emissive Boron Dyes for Tumor Accumulation  

UK PubMed Central (United Kingdom)

Responsive biomaterials play important roles in imaging, diagnostics, and therapeutics. Polymeric nanoparticles (NPs) containing hydrophobic and hydrophilic segments are one class of biomaterial...Full Text Available

2010-09-28

125

Stability of Trichomonas vaginalis DNA in Urine Specimens?  

UK PubMed Central (United Kingdom)

Trichomonas vaginalis is an important pathogen in both men and women. Culture is considered the diagnostic gold standard, although studies have shown that PCR is more sensitive than...Full Text Available

2008-05-01

126

Serum hepcidin as a diagnostic test of iron deficiency in premenopausal female blood donors  

UK PubMed Central (United Kingdom)

BackgroundCurrently used indicators of iron status have limitations. Hepcidin, a key regulator of iron metabolism, is reduced in iron deficiency. We sought to determine the properties...Full Text Available

2011-08-01

127

Rome III: The functional gastrointestinal disorders, third edition, 2006  

UK PubMed Central (United Kingdom)

Functional gastrointestinal disorders (FGIDs) represent a common and important class of disorders within gastroenterology. RomeI, the first edition was published in 1994, with symptom-based diagnostic...Full Text Available

2008-04-07

128

Reduced PCR Sensitivity Due to Impaired DNA Recovery with the MagNA Pure LC Total Nucleic Acid Isolation Kit  

UK PubMed Central (United Kingdom)

The increasing demand for molecular diagnostics in clinical microbiology laboratories necessitates automated sample processing. In the present study, we evaluated the performance of the MagNA Pure LC...Full Text Available

2005-09-01

129

Real-time system for processing regime diagnostic on accelerator  

International Nuclear Information System (INIS)

The automatic real-time system operating at the LU-10 linac and providing measurements of the parameters such as the beam current (average and pulse values), the electron energy, the linear density distribution of beam current, and also the conveyor speed is described in the paper.

130

Pubs.GISS: Ghil et al. 1977: A balanced ... - Publications - NASA  

Science.gov (United States)

Ghil, M., B. Shkoller, and V. Yangarber, 1977: A balanced diagnostic system compatible with a barotropic prognostic model. M. Weather. Rev. , 105, 1223- 1238, ...

131

Prenatal diagnosis for recessive dystrophic epidermolysis bullosa in 10 families by mutation and haplotype analysis in the type VII collagen gene (COL7A1).  

UK PubMed Central (United Kingdom)

BACKGROUND: Epidermolysis bullosa (EB) is a group of heritable diseases that manifest as blistering and erosions of the skin and mucous membranes. In the dystrophic forms of EB (DEB), the diagnostic...Full Text Available

1996-01-01

132

Performance and usefulness of the Hexagon rapid diagnostic test in children with asymptomatic malaria living in the Mount Cameroon region  

UK PubMed Central (United Kingdom)

BackgroundRapid and correct diagnosis of malaria is considered an important strategy in the control of the disease. However, it remains to be determined how well these tests can...Full Text Available

133

PROGRESS AND PROBLEMS IN THE APPLICATION OF FOCUSED ULTRASOUND FOR BLOOD-BRAIN BARRIER DISRUPTION  

UK PubMed Central (United Kingdom)

Advances in neuroscience have resulted in the development of new diagnostic and therapeutic agents for potential use in the central nervous system (CNS). However, the ability to deliver the...Full Text Available

2008-08-01

134

Optical and Structural Characteristics of Heavily Boron-Implanted CdTe.  

Science.gov (United States)

Cadmium telluride single crystals were subjected to multiple-energy boron ion implants with total doses up to 1.5 x 10 sq cm. Various diagnostic techniques were used to assess the structural and electronic properties of these crystals in their as-implante...

1988-01-01

135

Nuclear ? catenin as a potential prognostic and diagnostic marker in patients with colorectal cancer from Hong Kong  

UK PubMed Central (United Kingdom)

Aims: To study the expression of nuclear β catenin in patients with colorectal cancer, colorectal adenoma, and colorectal polyps to elucidate its role in carcinogenesis, and its...Full Text Available

2003-12-01

136

Multiplexed, rapid detection of H5N1 using a PCR-free nanoparticle-based genomic microarray assay  

UK PubMed Central (United Kingdom)

BackgroundFor more than a decade there has been increasing interest in the use of nanotechnology and microarray platforms for diagnostic applications. In this report, we describe...Full Text Available

137

Monitoring potential neurotoxic effects of hazardous waste disposal  

UK PubMed Central (United Kingdom)

This report reviews neurotoxicological principles relevant to situations of hazardous waste disposal. Some of the diagnostic techniques currently used for field assessment of nervous system dysfunction...Full Text Available

1983-02-01

138

Investigation of Dyslexia and SLI Risk Variants in Reading- and Language-Impaired Subjects  

UK PubMed Central (United Kingdom)

Dyslexia (or reading disability) and specific language impairment (or SLI) are common childhood disorders that show considerable co-morbidity and diagnostic overlaps and have been suggested to share...Full Text Available

2011-01-01

139

Impalpable Testis and Laparoscopy: When the Gonad Is Not Visualized  

UK PubMed Central (United Kingdom)

The diagnostic accuracy of laparoscopy for impalpable testis is well recognized. However, in some cases, laparoscopic findings may be misleading, and a viable gonad may be missed with significant medico-legal...Full Text Available

2004-01-01

140

Impact of radiation measurements on hardening of TFTR diagnostics  

International Nuclear Information System (INIS)

Contrary to previous plans for the preparation of diagnostic systems for D-T break-even experiments in the Tokamak Fusion Test Reactor (TFTR), it now appears that a limited Q#approx#1 demonstration can be carried out without constructing a close-fitting igloo radiation shield around the tokamak. In order to assess the impact of D-T operation of TFTR without an igloo shield, particularly with regard to hardening of diagonstic systems, we have mapped neutron and gamma fluxes inside the test cell and test cell basement, using a variety of radiation measurements. The measurements are sufficiently detailed to resolve massive hardware components, such as neutral beams and shielded diagnostic systems, and can be used to predict local fluxes. By comparing the measurements with transport code calculations for the case of a bare tokamak, we conclude that the models have substantially overestimated fluxes both inside and outside the TFTR shield walls. It ...

141

Identification of Cardiac Myosin-binding Protein C as a Candidate Biomarker of Myocardial Infarction by Proteomics Analysis*  

UK PubMed Central (United Kingdom)

Acute myocardial infarction (AMI) is a common cause of death for which effective treatments are available provided that diagnosis is rapid. The current diagnostic gold standards are circulating cardiac...Full Text Available

2009-12-01

142

IGENPRO knowledge-based digital system for process transient diagnostics and management  

Energy Technology Data Exchange (ETDEWEB)

Verification and validation issues have been perceived as important factors in the large scale deployment of knowledge-based digital systems for plant transient diagnostics and management. Research and development (R&D) is being performed on the IGENPRO package to resolve knowledge base issues. The IGENPRO approach is to structure the knowledge bases on generic thermal-hydraulic (T-H) first principles and not use the conventional event-basis structure. This allows for generic comprehensive knowledge, relatively small knowledge bases and above all the possibility of T-H system/plant independence. To demonstrate concept feasibility the knowledge structure has been implemented in the diagnostic module PRODIAG. Promising laboratory testing results have been obtained using data from the full scope Braidwood PWR operator training simulator. This knowledge structure is now being implemented in the transient management module PROMANA to treat ...

1997-12-31

143

How Missing Information in Diagnosis Can Lead to Disparities in the Clinical Encounter  

UK PubMed Central (United Kingdom)

Previous studies have documented diagnostic bias and noted that its reduction could eliminate misdiagnosis and improve mental health service delivery. Few studies have investigated clinicians'...Full Text Available

2008-11-01

144

Gonorrhoea in men: clinical and diagnostic aspects.  

UK PubMed Central (United Kingdom)

AIM: To review the features of gonococcal infection in men in the 1990s. METHODS: A retrospective study of all men with gonorrhoea presenting to an inner city department of genitourinary medicine in...Full Text Available

1996-12-01

145

Genetic screening: The vista of genomic medicine  

UK PubMed Central (United Kingdom)

The accelerating development of biochemical and DNA-based diagnostic tests for human genetic conditions in the last decade has engendered a revolution in genetic diagnosis. Both genetic testing and...Full Text Available

2011-01-01

146

Gamuts in nuclear medicine  

Energy Technology Data Exchange (ETDEWEB)

This book provides differential diagnostic possibilities of specific scan abnormalities in one volume for easy reference. This book is organized by organ systems and covers the central nervous system, the endocrine, skeletal, pulmonary, gastrointestinal, genitourinary, and cardiovascular systems. The gamuts are designed to teach differential diagnosis and to assist in the actual interpretation of patient slides.

1983-01-01

147

Fetal, perinatal, and infant death with congenital renal anomaly  

UK PubMed Central (United Kingdom)

Aims: To ascertain why 19.6% of pregnancies in which a fetal renal anomaly has been detected fail to produce a surviving child, and whether antenatal diagnostic accuracy has altered since...Full Text Available

2002-08-01

148

Fetal ascites: an unusual presentation of Niemann-Pick disease type C.  

UK PubMed Central (United Kingdom)

Two infants were seen with severe ascites detected before birth, a previously unreported presentation of Niemann-Pick disease type C. In the second infant no diagnostic storage cells were present in...Full Text Available

1989-10-01

149

Evaluation of the OptiMAL Test for Rapid Diagnosis of Plasmodium vivax and Plasmodium falciparum Malaria  

UK PubMed Central (United Kingdom)

The development of rapid and specific diagnostic tests to identify individuals infected with malaria is of paramount importance in efforts to control the severe public health impact of this disease....Full Text Available

1998-01-01

150

Evaluation of a diagnostic algorithm for heart disease in neonates.  

UK PubMed Central (United Kingdom)

OBJECTIVE--To develop, test, and validate an algorithm for diagnosing disease in neonates during an over the telephone referral to a specialist cardiac centre. DESIGN--A draft algorithm requiring only...Full Text Available

1991-04-20

151

Electrostatic probe vacuum system for TCA BR tokamak  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the technical design and performance of the diagnostic system installed in the tokamak TCABR to measure parameters of the plasma edge. The system consists of four Langmuir probes under remote control. (author)

1999-12-01

152

Diagnostics of Gun Barrel Propellants.  

Science.gov (United States)

Page 1. Page 2. Page 3. Page 4. Page 5. Page 6. Page 7. Page 8. Page 9. Page 10. Page 11. Page 12. Page 13. Page 14. Page 15. Page 16. Page ...

1983-11-01

153

Diagnostic quality of low resolution images for tele-woundcare.  

UK PubMed Central (United Kingdom)

The use of digital wound images would allow remote consultation between patients, physicians, or other caregivers over the Internet. To evaluate the efficacy and validity of digital images for assessment...Full Text Available

1998-01-01

154

Diagnostic Dilemma in an Unusual Case of Common Bile Duct Obstruction  

UK PubMed Central (United Kingdom)

Biliary obstructions are rarely caused by a foreign body and have received sparse attention. We present an unusual case with pruritis and abdominal pain caused by impacted full length surgical gauze...Full Text Available

2011-06-01

155

Development and Application of Pathovar-Specific Monoclonal Antibodies That Recognize the Lipopolysaccharide O Antigen and the Type IV Fimbriae of Xanthomonas hyacinthi  

UK PubMed Central (United Kingdom)

The objective of this study was to develop a specific immunological diagnostic assay for yellow disease in hyacinths, using monoclonal antibodies (MAbs). Mice were immunized with a crude cell wall preparation...Full Text Available

1999-09-01

156

Decreased CSF Transferrin in sCJD: A Potential Pre-Mortem Diagnostic Test for Prion Disorders  

UK PubMed Central (United Kingdom)

Sporadic Creutzfeldt-Jakob-disease (sCJD) is a fatal neurodegenerative condition that escapes detection until autopsy. Recently, brain iron dyshomeostasis accompanied by increased transferrin (Tf) was...Full Text Available

157

Cystic neoplasms of the pancreas: A diagnostic challenge  

UK PubMed Central (United Kingdom)

Cystic neoplasms of the pancreas are increasingly recognized due to the expanding use and improved sensitivity of cross-sectional abdominal imaging. Major advances in the last decade have led to an...Full Text Available

2009-01-07

158

Comparing the Diagnostic Performance of 2 Clinical Decision Rules to Rule Out Deep Vein Thrombosis in Primary Care Patients  

UK PubMed Central (United Kingdom)

PURPOSE The Wells rule is widely used for clinical assessment of patients with suspected deep vein thrombosis (DVT), especially in the secondary care setting. Recently a new clinical decision...Full Text Available

2011-01-01

159

Colonic polyps: inheritance, susceptibility, risk evaluation, and diagnostic management  

UK PubMed Central (United Kingdom)

Colorectal cancer (CRC) is the third-ranked neoplasm in order of incidence and mortality, worldwide, and the second cause of cancer death in industrialized countries. One of the most important environmental...Full Text Available

160

Clinical value of SPECT/CT for evaluation of patients with painful knees after total knee arthroplasty- a new dimension of diagnostics?  

UK PubMed Central (United Kingdom)

BackgroundThe purpose of our study was to evaluate the clinical value of hybrid SPECT/CT for the assessment of patients with painful total knee arthroplasty (TKA).MethodsTwenty-three...Full Text Available

161

Clinical efficacy of the use of information technology in cardiology: initial results of angiographic teleconsultation in the Netherlands  

UK PubMed Central (United Kingdom)

Background With the increasing use of cineless diagnostic angiography laboratories, modern telecommunication networks provide an excellent opportunity to transfer dynamic cardiac...Full Text Available

2001-12-01

162

Characteristics of common solid liver lesions and recommendations for diagnostic workup  

UK PubMed Central (United Kingdom)

Due to the widespread clinical use of imaging modalities such as ultrasonography, computed tomography and magnetic resonance imaging (MRI), previously unsuspected liver masses are increasingly being...Full Text Available

2009-07-14

163

CT evaulation of thoracic and abdominal fatty masses  

International Nuclear Information System (INIS)

The diagnostic accuracy of computed tomography (CT) in several patterns of thoracic and abdominal fatty masses, has been examined. In selected cases our findings overlap the features of the recent literature. The possibility of surgical therapy in peculiar cases of adipose deposits, commonly esteemed benign, is considered.

1986-01-01

164

Blood conservation strategies to reduce the need for red blood cell transfusion in critically ill patients  

UK PubMed Central (United Kingdom)

Anemia commonly affects critically ill patients. The causes are multifactorial and include acute blood loss, blood loss from diagnostic testing and blunted red blood cell production. Blood transfusions...Full Text Available

2008-01-01

165

Bilateral Pneumothorax and Subcutaneous Emphysema following Endoscopic Retrograde Cholangiopancreatography: A Rare Complication  

UK PubMed Central (United Kingdom)

Endoscopic Retrograde Cholangiopancreatography (ERCP) is a widely used diagnostic and therapeutic modality in the management of biliary and pancreatic disease. Some of the complications of the procedure,...Full Text Available

2010-01-01

166

Anti-albumin antibodies in chronic liver diseases: diagnostic significance of these antibodies in patients with conventional or immunosuppressive therapy.  

UK PubMed Central (United Kingdom)

The two categories of anti-albumin antibodies (AAA), namely precipitins (AA-P) and agglutinins (AA-Aggl), were investigated in 260 patients with morphologically diagnosed chronic liver diseases (CLD)....Full Text Available

1981-02-01

167

An evaluation of cerebrospinal fluid oligoclonal banding confirmed by immunofixation on agarose gel.  

UK PubMed Central (United Kingdom)

The cerebrospinal fluid (CSF) from 115 consecutive patients undergoing diagnostic lumbar puncture or myelography was examined to determine the usefulness of immunofixation, following agarose gel electrophoresis,...Full Text Available

1983-06-01

168

Affinity maturation of human botulinum neurotoxin antibodies by light chain shuffling via yeast mating  

UK PubMed Central (United Kingdom)

Botulism is caused by the botulinum neurotoxins (BoNTs), the most poisonous substance known. Because of the high potency of BoNT, development of diagnostic and therapeutic antibodies for botulism requires...Full Text Available

2010-04-01

169

Advances in cancer tissue microarray technology: Towards improved understanding and diagnostics  

UK PubMed Central (United Kingdom)

Over the past few years, tissue microarray (TMA) technology has been established as a standard method for assessing the expression of proteins or genes across large sets of tissue specimens....Full Text Available

2006-03-30

170

Advances in Fine Needle Aspiration Cytology for the Diagnosis of Pulmonary Carcinoma  

UK PubMed Central (United Kingdom)

New developments in the field of thoracic oncology have challenged the way pathologists approach the diagnosis of pulmonary carcinoma. Nonsmall cell carcinoma is no longer an adequate diagnostic category....Full Text Available

171

Accuracy of electrocardiographic and echocardiographic indices in predicting life threatening ventricular arrhythmias in patients operated for tetralogy of Fallot  

UK PubMed Central (United Kingdom)

OBJECTIVE—To validate the accuracy of the prognostic significance of non-invasive clinical diagnostic indices as predictors of sustained ventricular tachycardia (sVT) or fibrillation...Full Text Available

1999-06-01

172

A survey on clinical presentation and nutritional status of infants with suspected cow' milk allergy  

UK PubMed Central (United Kingdom)

BackgroundCow's milk is the most common food allergen in infants and the diagnosis of cow's milk allergy is difficult, even with the use of several diagnostic tests. Therefore, elimination...Full Text Available

173

A diagnostic survey of infants referred for chromosome analysis in the neonatal period.  

UK PubMed Central (United Kingdom)

Examination and assessment of 140 liveborn and stillborn infants referred within two weeks of birth for chromosome analysis showed that 48 had Down's syndrome, 12 other chromosome abnormalities, 17...Full Text Available

1980-10-18

174

Tolerance limits of X-ray image intensity  

International Nuclear Information System (INIS)

Evaluation of the tolerance limits of X-ray image density accepted by the radiologist shows that for different kinds of examinations, deviations of more than 50% from optimal density lead to images which cannot be used diagnostically. Within this range diagnostic accuracy shows a distinct maximum and diminishes to the limits by 20%. These figures are related to differences in the intensifying factor of screens, sensitivity of films, sensitometric parameters of film processing as well as the doses employed with automatic exposure control devices, measured in clinical conditions. Maximum permissible tolerance limits of the whole imaging system and of its constituents are discussed using the Gaussian law of error addition. (author).

175

Thomson scattering: a powerful diagnostic tool of plasma physics  

International Nuclear Information System (INIS)

Thomson scattering is the process in which a low-energy photon scatters from a free electron. When a laser pulse propagates through a plasma, the spectrum of the scattered light due to the Thomson scattering is proportional to the power spectrum of the electron density fluctuations, i.e., dynamic form factor, from which various plasma parameters can be inferred, such as electron temperature and plasma flow velocity. After years of development. Thomson scattering has now become a powerful diagnostic tool of plasma physics. (authors)

2008-08-01

176

Somatic radiation risk in X-ray diagnostics  

Energy Technology Data Exchange (ETDEWEB)

The authors give a survey of the somatic radiation risk in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk.

1983-12-01

177

Somatic radiation risk in X-ray diagnostics  

International Nuclear Information System (INIS)

The authors give a survey of the somatic radiation ris in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk. (orig.).

1983-01-01

178

Radiodiagnosis of Ewing's sarcoma of the rib in children  

International Nuclear Information System (INIS)

The results of the examination of 23 children with Ewing's sarcoma of the rib were analyzed: panoramic chest X-rays in 4 projections, spot radiographs of the robs, superexposed pictures, laterograms, urography, angiography, computerized tomography, and scanning of the skeleton. Causes of diagnostic errors made at the first consultation by a physician, were identified. Peculiarities of X-ray signs of tumors of this site in children were studied. Diagnostic difficulties in tumors complicated by pleurisy and in tumors of small sizes with extrapleural growth were shown. Inclusions in the extraoseous tumor component were noted in 8.7% of the cases.

179

Radiation risk in diagnostic radiology  

International Nuclear Information System (INIS)

An attempt was made to quantify the radiation risk of diagnostic radiology. After a general introduction of terms as radiation damage, radiation risk and effective dose equivalent, based on publications of the ICRP, somatic dose indexes were computed for several radiologic investigations, that comprise organ doses committed to red bone marrow, lung, female breast and thyroid with and without considering the rest of the body. The dose for the rest of the body was assumed to be equal to the dose received by the red bone marrow, that is also distributed over the whole body. Neglecting the exposure of the rest of the body resulted in an insignificant increase in the estimated somatic risk, with its experimental determination not being necessary. (author).

1984-01-01

180

Projection techniques in diagnostic radiography discussed with regard to required dose  

International Nuclear Information System (INIS)

The paper presents information in the form of data, tables and diagrams compiled to a broad but very up-to-date survey of required radiation for the various most frequently performed X-ray examinations of patients. The required dose is discussed from the point of view of radiation protection, defining the inevitably administered dose to the skin, the frequency of examinations, and the diagnostic image quality as the main three factors to be observed, as these determine the radiation dose to the patient and to the personnel. The somatic risks of radiography examinations are a point of main interest. (DG).

1990-09-01

181

Post-transplant monitoring of renal allografts: are we there yet?  

British Library Electronic Table of Contents (United Kingdom)

Transplantation has emerged as the therapy of choice for many patients with end organ failure. One of the major goals is to tailor immunosuppressive therapy to the individual needs of every patient to balance the risk for rejection and over-immunosuppression. This will require diagnostic tools that can detect harmful processes in the allograft early, and that can be measured repeatedly. This review will consider recent advances in our understanding of the molecular nature of these processes and how this information is being utilized to design novel diagnostic assays to non-invasively monitor allografts. Highlighted is the need for large-scale prospective multi-centre studies to validate assays that show early promise in single centre studies.

2009-01-01

182

NuMI proton beam diagnostics and control: achieving 2 megawatt capability  

Energy Technology Data Exchange (ETDEWEB)

The NuMI proton beam at Fermilab currently delivers 120 GeV protons to the neutrino production target with design beam power capability to 400 kW. Upgrade capability to 700 kW is being prepared, with planning toward delivering 2.3 MW beam provided by the Project X accelerator upgrade plan. We report on the system of beam diagnostics and control used in operation of the NuMI beam. Also considered are the steps to provide a robust system for transport and targeting beam of 2 MW and beyond.

2008-10-01

183

GPLS VME MODULE: A DIAGNOSTIC AND DISPLAY TOOL FOR NSLS MICRO SYSTEMS.  

Energy Technology Data Exchange (ETDEWEB)

The General Purpose Light Source VME module is an integral part of every front-end micro in the NSLS control system. The board incorporates features such as a video character generator, clock signals, time-of-day clock, a VME bus interrupter and general-purpose digital inputs and outputs. This module serves as a valuable diagnostic and real-time display tool for the micro development as well as for the final operational systems. This paper describes the functions provided by the board for the NSLS micro control monitor software.

1999-03-29

184

Evaluation of the chest radiography using Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Chest radiograms obtained by using Fuji Computed Radiography (FCR) system were compared to conventional film/screen radiograms. The FCR images showed better image quality in diagnostic information than the conventional chest images. In FCR, the radiation exposure to patient for chest examination could be reduced up to one tenths of conventional chest examination. The main advantages or FCR were considered to depend on the contrast processing and frequency processing properties. The use of FCR in clinical work may improve both diagnostic quality and radiation exposure.

1991-12-01

185

Electron temperature diagnostics in the RFX reversed field pinch experiment  

Energy Technology Data Exchange (ETDEWEB)

The paper presents an integrated approach to the problem of electron temperature diagnostics of the plasma in a reversed field pinch. Three different methods, sampling different portions of the electron distribution function, are adopted, namely Thomson scattering, soft X-ray spectroscopy by pulse-height analysis and filtered soft X-ray intensity ratio. A careful analysis of the different sources of systematic errors is performed and a novel statistical approach is adopted to mutually validate the three independent measurements. A satisfactory agreement is obtained over a large range of experimental conditions, indicating that in the plasma core the energy distribution function is well represented by a maxwellian. (author)

2000-08-01

186

Efficient application of medical imaging methods. Graded diagnostics for surgical and internal medical problems. Rationeller Einsatz bildgebender Verfahren. Gestufte Diagnostik bei chirurgischen und internistischen Krankheitsbildern  

Energy Technology Data Exchange (ETDEWEB)

The book is intended as a source of information for general practioners and for medical students doing their practical training. Efficient application of imaging methods is explained with great emphasis on practical aspects, concentrating on typical tasks to be solved for adult patients with internal disease or surgical problems. The material is arranged by various organic systems of the body. Graded diagnostics for a stepwise approach to the final diagnosis is the concept described, and is shown to be of advantage to the patient and in terms of cost and time.

1985-01-01

187

Clinical magnetic resonance imaging with nuclear medicine correlation  

Energy Technology Data Exchange (ETDEWEB)

The current role of magnetic resonance imaging (MRI) in different organ systems is discussed and compared to nuclear medicine and to other available clinical diagnostic modalities. The value of optimizing radiofrequency pulse sequence selection to provide additional tissue characterization is also described. The results of nuclear medicine and MRI studies in 56 patients are compared to evaluate the clinical diagnostic contribution of each imaging modality for various pathological processes. In addition, the state-of-the-art MRI systems and future development in MRI technology with its potential contribution is defined.

1985-08-01

188

Performance of Brazilian thermoluminescent CaSO{sub 4}: Dy pellets in standard diagnostic radiology beams  

Energy Technology Data Exchange (ETDEWEB)

The high sensitivity of CaSO{sub 4}: Dy as a thermoluminescent material is a great advantage when dealing with low dose levels, as in diagnostic radiology procedures. However, these kinds of dosemeters present a high energy dependence that must be precisely determined in the energy range of interest. Dosimetric pellets of CaSO{sub 4}: Dy are produced at IPEN since the end of the 80 Th decade. These pellets are produced in three forms: conventional CaSO{sub 4}: Dy (50 mg); thin CaSO{sub 4}: Dy (20 mg) and CaSO{sub 4}: Dy + 10% C (20 mg). The main applications of these dosemeters are in personal and environmental dosimetry. In this study, CaSO{sub 4}: Dy pellets produced at IPEN were evaluated in diagnostic radiology standard beams. These qualities are based on the IEC 61267 standard, and they were established at an industrial X-ray system Pantak/Seifert, model ISOVOLT 160HS. Former studies evaluated CaSO{sub 4}: Dy of different origins in ...

2006-07-01

189

Probabilistic leak before break evaluation of straight pipes of primary heat transport piping of Tarapur-3 and 4 NPP  

International Nuclear Information System (INIS)

Piping systems transporting high-pressure fluid will release a large amount of energy, leading to whipping of the broken pipe as well as impingement of the ejecting fluids on adjacent structures if they fracture unstably. Postulation of such an event in design of piping systems in nuclear power plants often requires various counter measures such as installation of pipe whip restraints or jet impingement shields to prevent such damage. One of the approaches to justify exclusion of unstable fracture from the design conditions is leak-before-break (LBB) analysis. In order to demonstrate LBB behavior, it is necessary to prove that in the presence of a part-through wall flaw in the pipe, this flaw will not grow through the wall under fatigue loading and is stable (level 2 LBB) and that the leak of fluid through the penetration is detected by leak detection systems before unstable fracture occurs (level 3 LBB). If this can be demonstrated in plant design, significant reduction of ...

2006-11-01

190

Stochastic risk estimation from medical x-ray diagnostic examinations, 2  

International Nuclear Information System (INIS)

The risks of genetic, leukemia and malignant diseases from medical X-ray diagnostic examinations were estimated using the frequency of radiographic and fluoroscopic exposures per diagnostic examination, child expectancy, leukemia and malignancy significant factors, and using a weighting factor determined on the basis of data concerning the cancer mortality among atomic bomb survivors in Nagasaki and of a recommendation of International Commission of Radiological Protection. The organ or tissue doses with respect to the stochastic risks were determined with ionization chambers and thermoluminescent dosimeters placed at the positions of the organs or tissues in a RANDO woman phantom which was exposed to diagnostic X-rays according to technical factors of typical radiographic and fluoroscopic examinations obtained from a nationwide survey. The resultant risks by age-group and type of radiographic and fluoroscopic examination ...

1981-01-01

191

Diagnostics aid for mass spectrometer trouble-shooting  

International Nuclear Information System (INIS)

The MS Expert system provides problem diagnostics for instruments used in the Mass Spectrometry Laboratory (MSL). The most critical results generated on these mass spectrometers are the uranium concentration and isotopic content data used for process control and materials accountability at the Idaho General Processing Plant. The two purposes of the system are: (1) to minimize instrument downtime and thereby provide the best possible support to the Plant, and (2) to improve long-term data quality. This system combines the knowledge of several experts on mass spectrometry to provide a diagnostic tool, and can make these skills available on a more timely basis. It integrates code written in the Pascal language with a knowledge base entered into a commercial expert system shell. The user performs some preliminary status checks, and then selects from among several broad diagnostic categories. These initial steps provide input to ...

192

The accuracy and reverse effects of thallium myocardial SPECT using adenosine triphosphate loading in the diagnosis of coronary artery disease. Comparison with other loading methods semiquantitatively  

Energy Technology Data Exchange (ETDEWEB)

The adverse effects and diagnostic accuracy of thallium-201 myocardial SPECT after intravenous infusion of adenosine triphosphate (ATP) were studied and compared with SPECT examinations with other type of loading. The subjects of the study were 147 patients with or without coronary artery disease, who underwent some type of loading SPECT and coronary arteriography (CAG) within 30 days. Myocardial ischemia was evaluated qualitatively in SPECT and was compared with CAG for the diagnostic accuracy of coronary artery disease. The degree of myocardial uptake defect was also calculated semiquantitatively using visual scoring method and compared with coronary artery severity score. The adverse effects occurred in 46.7% of ATP loading SPECT which was more frequent that DIP loading SPECT, but all of them were transient and mild. As for the diagnostic ability the ATP loading SPECT was as effective as other type of loading in ...

1999-09-01

193

Radiation hardening of diagnostics  

International Nuclear Information System (INIS)

The world fusion program has advanced to the stage where it is appropriate to construct a number of devices for the purpose of burning DT fuel. In these next-generation experiments, the expected flux and fluence of 14 MeV neutrons and associated gamma rays will pose a significant challenge to the operation and diagnostics of the fusion device. Radiation effects include structural damage to materials such as vacuum windows and seals, modifications to electrical properties such as electrical conductivity and dielectric strength and impaired optical properties such as reduced transparency and luminescence of windows and fiber optics during irradiation. In preparation for construction and operation of these new facilities, the fusion diagnostics community needs to work with materials scientists to develop a better understanding of radiation effects, and to undertake a testing program aimed at developing workable solutions for this multi-faceted ...

194

Radial distribution of superthermal electrons measured with ECE (abstract)  

International Nuclear Information System (INIS)

To aid in the study of lower hybrid current drive as a means of current profile control, the radial profile and velocity distribution of the fast current-carrying electrons and their time evolution must be known. As part of the recent effort to understand this fast electron transport, a diagnostic has been installed on PBX-M to measure the electron cyclotron emission from the fast electrons. An oblique horizontal view of upshifted cyclotron emission in the midplane can give radial as well as velocity space information about the fast electrons. Emission in X mode frequencies refracted by the right-hand cutoff is radially localized. The observed emission at a specific frequency comes only from the radial region r_t_u_r_n=#0. Emission measured by this new diagnostic has been found to be radially localized as predicted. It is also expected that localized moments of the distribution function may be obtained from these data. A superheterodyne ...

0854-01-01

195

Optical diagnostics for turbulent and multiphase flows: Particle image velocimetry and photorefractive optics  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the work performed under the Sandia Laboratory Directed Research and Development (LDRD) project ``Optical Diagnostics for Turbulent and Multiphase Flows.`` Advanced optical diagnostics have been investigated and developed for flow field measurements, including capabilities for measurement in turbulent, multiphase, and heated flows. Particle Image Velocimetry (PIV) includes several techniques for measurement of instantaneous flow field velocities and associated turbulence quantities. Nonlinear photorefractive optical materials have been investigated for the possibility of measuring turbulence quantities (turbulent spectrum) more directly. The two-dimensional PIV techniques developed under this LDRD were shown to work well, and were compared with more traditional laser Doppler velocimetry (LDV). Three-dimensional PIV techniques were developed and tested, but due to several experimental difficulties were not as successful. ...

1997-01-01

196

Myocardial perfusion SPECT in patients after myocardial infarction: Comparison of "2"0"1Tl and dual-isotope protocol (rest "2"0"1Tl/stress "9"9"mTc tetrofosmin)  

International Nuclear Information System (INIS)

The diagnostic accuracy is compared of the dual-isotope protocol and the conventional "2"0"1Tl protocol, for detection of the coronary artery disease (CAD) using data on a total of 69 patients after myocardial infarction (MI). The "2"0"1Tl protocol was used to examine 44 patients, the dual-isotope protocol was used with 25 patients. All patients were examined by coronarography; a narrowing of the artery by more than 50 % was considered significant for CAD. The sensitivity, specificity and diagnostic accuracy was 97.7 %, 100 % and 97.7 % resp. for the "2"0"1Tl protocol, and 95.2 %, 75 % and 92 % resp. for the dual-isotope protocol. A higher diagnostic accuracy of the dual-isotope protocol has not been proven, and the "2"0"1Tl protocol continues to be used for examinations of patients after MI

1998-08-01

197

Measurement of dose-area product in diagnostic radiology as a method of assessing the radiation exposure. (Results, experience, proposals for improvement, recommendations relating to radiological protection). Report of an expert meeting  

International Nuclear Information System (INIS)

The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product measurement in the dosimetry activities in medical ...

198

MTX diagnostic and timing system for free-electron laser heating experiments  

International Nuclear Information System (INIS)

In the microwave tokamak experiment (MTX) program, we are concentrating on experiments using intense, free-electron laser (FEL) generated microwave pulses. In initial FEL experiments, several diagnostic instruments were operated during injection of microwave pulses with peak powers to 0.2 GW at durations of 10 ns. Fixed and spatially scanning microwave detectors and receivers and a 48-element calorimeter on the inside wall of MTX diagnosed the GW-level FEL microwave pulses. With these diagnostics, linear-wave absorption and efficiencies of transmission through the quasi-optical transport system were studied. In addition, several radially resolved measurements of plasma density, temperature, and emission were made during FEL injection and were used in the analysis of microwave absorption data. A timing system, slaved to the FEL pulse arrival time, is capable of accuracy to a few nanoseconds in order to allow measurement of heating effects on the ...

199

Lymph node staging in cervical carcinoma: Results of high resolution MRT with phased-array coil  

International Nuclear Information System (INIS)

Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T_2-weighted turbo-spin-echo (TSE) and T_1-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm"2. Lymph nodes with a diameter of #>=#8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes (#>=# 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of 24 cases MR findings were true negative (specificity 92%). Diagnostic accuracy was 91%. Conclusion: ...

200

He-like ions as practical astrophysical plasma diagnostics: From stellar coronae to active galactic nuclei  

CERN Document Server

We review X-ray plasma diagnostics based on the line ratios of He-like ions. Triplet/singlet line intensities can be used to determine electronic temperature and density, and were first developed for the study of the solar corona. Since the launches of the X-ray satellites Chandra and XMM-Newton, these diagnostics have been extended and used (from CV to Si XIII) for a wide variety of astrophysical plasmas such as stellar coronae, supernova remnants, solar system objects, active galactic nuclei, and X-ray binaries. Moreover, the intensities of He-like ions can be used to determine the ionization process(es) at work, as well as the distance between the X-ray plasma and the UV emission source for example in hot stars. In the near future thanks to the next generation of X-ray satellites (e.g., Astro-H and IXO), higher-Z He-like lines (e.g., iron) will be resolved, allowing plasmas with higher temperatures and densities to be probed. Moreover, the ...

2011-01-01

201

Estimation of population doses from medical uses of radiopharmaceuticals in Japan, 1977, 2  

International Nuclear Information System (INIS)

Population doses from diagnostic and therapeutic uses of radiopharmaceuticals have been estimated on the basis of a nation wide survey data on the number of investigations and treatments used radiopharmaceuticals in the nuclear medicine and the annual amount of their activities. The gonad and marrow doses were calculated from published biokinetics data from humans, employing the MIRD method. The resultant annual genetically significant dose from diagnostic and therapeutic uses of radiopharmaceuticals was 0.36 and 0.02 mrad (3.6 and 0.2 #mu#Gy) per person, respectively, with a total 0.38 mrad (3.8 #mu#Gy) per person. The annual per Caput mean bone marrow dose was 2.3 mrad (23 #mu#Gy) for diagnosis and 0.2 mrad (2 #mu#Gy), for therapy. The resultant annual leukemia significant dose was 1.8 mrad (18 #mu#Gy) per person for diagnostic uses and 0.2 mrad (2 #mu#Gy) per person for therapeutic use, with a total of 2.0 mrad (20 ...

1979-01-01

202

Diagnostic features of intrahepatic cholangiocarcinoma according to the gross type classification  

International Nuclear Information System (INIS)

Forty resected cases of intrahepatic cholangiocarcinoma were classified into four types according to the gross appearance; type I: mass forming type (n=8), type II: mass forming with periductal infiltrating type (n=20), type III: periductal infiltrating type (n=9) and type IV: intraductal growth type (n=3). Diagnostic features of these four types were studied. Peripheral enhancement was a common angiographic feature and tumor stains were recognized in 88%, 20%, 0%, 33%, respectively. Angiography and dynamic computed tomography (D-CT) were useful in differential diagnosis with hepatocellular carcinoma. Accuracy rate in diagnosis of portal vein involvement by angiography and D-CT was 82% and 91%, respectively. MRI was more useful in tumor detection than D-CT in cases with attenuation difference, in 55% of type II and in 75% of type III. Increase of arterial involvement, biliary tract involvement and portal vein involvement, incidence of lymph nodes metastases became ...

1998-08-01

203

Design of the electromagnetic fluctuations diagnostic for MFTF-B  

Energy Technology Data Exchange (ETDEWEB)

The Electromagnetic Fluctuations (EMF) diagnostic will be used to monitor ion fluctuations which could be unstable in MFTF-B. Each probe assembly includes a high impedance electrostatic probe to measure potential fluctuations, and a group of nested, single turn loops to measure magnetic fluctuations in three directions. Eventually, more probes and loops will be added to each probe assembly for making more detailed measurements. The sensors must lie physically close to the plasma edge and are radially positionable. Also, probes at separate axial locations can be positioned to connect along the same magnetic field line. These probes are similar in concept to the rf probes used on TMX, but the high thermal load for 30-second shots on MFTF-B requires a water-cooled design along with temperature monitors. Each signal channel has a bandwidth of .001 to 150 MHz and is monitored by up to four different data channels which obtain amplitude and frequency information. This ...

1983-11-28

204

Achievement report for fiscal 1998. Research and development of a multi-plant maintenance system (the first year); 1998 nendo seika hokokusho. Odanteki maintenance gijutsu no kenkyu kaihatsu (dai 1 nendo)  

Energy Technology Data Exchange (ETDEWEB)

This research and development is intended to structure a network centering around a center having systematized high-level maintenance technology, by utilizing the technological infrastructure having been built in local areas, together with element technologies possessed by national and private research institutes, universities and colleges. It is also purposed to establish a new industrial system for maintenance to realize high reliability, high operation rate and low cost in plants in certain areas. The present fiscal year had the following achievements: research and development of a maintenance system, a maintenance model, a maintenance vehicle, damage estimating technology for stationary parts such as piping, an anomaly diagnostic system using acoustic emission, an anomaly diagnostic system using wear particles in lubricant, an anti-wear material using surface modification, a lubrication control system, and an anomaly ...

1999-03-01

205

A new application of MRT of the lung using ultra-shot turbo spin echo sequences (UTSE)  

International Nuclear Information System (INIS)

T_2 weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T_E=90 ms, T_R=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good quality. Compared with CT, contrast is better with MRT, offering diagnostic ...

206

Yield-increasing additives in kraft pulping: Effect on carbohydrate retention, composition and handsheet properties  

Energy Technology Data Exchange (ETDEWEB)

In this thesis, increased hemicellulose retention during kraft pulping has been studied. The work has been divided into three parts: i) Development of an accessible and reliable method for determination of carbohydrate composition of kraft pulps ii) Investigation of the composition and molecular mass distributions of the carbohydrates in kraft pulps with increased hemicellulose content iii) Investigation of the effect of increased hemicellulose content on the sheet properties of kraft pulps with increased hemicellulose content. A method for carbohydrate determination was developed. In this method, enzymes are used to hydrolyse the pulp into monosaccharides. A relatively mild acid hydrolysis is performed prior to detection on an HPLC with an RI-detector. The pulp is not derivatized and no pre-treatment (mechanical or chemical) is needed to determine the carbohydrate composition using the method developed here. Peak deconvolution software is used to improve the accuracy. Polysulphide and ...

2008-07-01

207

The tactical use of constraints and structure in diagnostic problem solving  

British Library Electronic Table of Contents (United Kingdom)

This paper presents a prescriptive account of diagnostic problem solving, or diagnosis, in quality and process control. This paper identifies a general strategy, named branch-and-prune, whose manifestations can be found in disciplines such as medical diagnosis, troubleshooting of devices, and model-based diagnosis in artificial intelligence. The work aims to offer a clear conceptualization of this strategy, based on the notions of structures for the search space, and constraints to the cause's nature.The idea is to treat the search space of candidate explanations as a tree structure, in which general and high-level causal directions are branched into more specific and detailed explanations. Constraints eliminate all but a few branches (pruning), which are explored in more detail. We enumer...

2011-01-01

208

Somatic effects in nuclear medicine and radiology  

International Nuclear Information System (INIS)

Probable risks for the occurrence of somatic effects due to diagnostic radiology and nuclear medicine are summarised. The biological background of radiation carcinogenesis and epidemiological results are discussed. At the Leiden University Medical Centre the average effective dose per examination due to diagnostic radiology and nuclear medicine amount to 0.95 and 4.4 mSv, respectively. These values correspond well with the average values of 0.82 and 3.0 mSv reported for The Netherlands as a whole. Since radiological examinations are performed at a much larger frequency than nuclear medicine the relative collective dose for the first type of examinations is higher than the latter. Risk for occurency of malignancies are at least one order of magnitude lower than the hypothetical risk due to the background radiation typical of The Netherlands.

1999-01-01

209

Plasma diagnostics by spectra from LHD and atomic data  

International Nuclear Information System (INIS)

We have observed EUV spectra from the Large Helical Device (LHD) at the National Institute for Fusion Science (NIFS). We measured spectra of impurity ions; carbon, iron, xenon, tin and tungsten ions. In some cases, the plasma evolution was stable and a steady discharge was obtained, but sometimes the plasma underwent radiation collapse and rapid cooling. For carbon and iron spectra, we studied plasma diagnostics by intensity ratios of spectral lines. For other spectra of higher Z element, xenon, tin and tungsten, we studied mainly on line identifications comparing with theoretical calculations and experimental data. Related atomic data for these researches will be also discussed. (author)

2009-04-01

210

Magnetic beam position monitor  

Energy Technology Data Exchange (ETDEWEB)

Many nondestructive beam position monitors are known. However, these devices can not be used for DC particle beam diagnostics. We investigated a method of beam diagnostics applicable for the operative control of DC high power e-beam inside closed waveguide. A design of the detector for determination of{open_quote} center of mass {close_quote} position of DC particle beam was developed. It was shown that the monitor can be used as a nondestructive method for the beam position control in resonators. Magnetic field of the particle beam outside a resonator is used. The detector consists of the steel yokes and magnetic field sensors. The sensors measure magnetic fluxes in the steel yokes fixed outside the resonator. When the particle beam changes its position, these magnetic fluxes also change. Beam displacement sensitivity of the monitor depends on the steel yoke dimensions. The detector sensitivity is equal to 1 Gauss/mm for the conditions ...

1995-12-31

211

Interaction of dioxygen with the electronic excited state of Ir(III) and Ru(II) complexes: Principles and biomedical applications  

British Library Electronic Table of Contents (United Kingdom)

Luminescent transition metal complexes are enjoying a growing interest because of their ubiquitous applications in, e.g., the fields of material science, sensors and (biomedical) diagnostics, and iridium(III) and ruthenium(II) complexes are among the best studied. Due to their long-living excited states, these complexes can have a strong interaction with dioxygen, resulting in luminescence quenching. This oxygen quenching might be regarded as an unwanted effect in luminescence imaging, but, on the other hand, it can be exploited for diagnostic and therapeutic applications as well. After a theoretical introduction concerning the dioxygen quenching mechanism and the parameters involved, in the second part of this review we focus on the possibility of tailoring this quenching by modifying sel...

2011-01-01

212

Identification and staging of bladder carcinoma  

International Nuclear Information System (INIS)

The purpose of the present study was to compare the effectiveness of MRI, CT and radioimmunoscintigraphy in the staging and detection of bladder cancers in 28 patients. We distinguish two groups: Group I included the tumour stages CIS-T_3_A and the second group the deep infiltrative tumours T_3_B-T_4. MRI was slightly superior to CT in respect of tumour staging (75% correct results as compared to 63%). No understaging occurred with MRI, whereas in 22% of the cases the stage of the tumour was underestimated using CT diagnostics. Overstaging occurred in 25% of the MRI and 15% of the CT-diagnostics, respectively. RIS cannot distinguish the tumour groups, and hence this method is useful only for the detection of the primary tumour and metastases. In 77% of cases the tumour was detected and in 15% the tumour could be safely excluded. (orig.).

213

Fundamental limits on beam stability at the advanced photon source  

International Nuclear Information System (INIS)

Orbit correction is now routinely performed at the few-micron level in the Advanced Photon Source (APS) storage ring. Three diagnostics are presently in use to measure and control both AC and DC orbit motions: broad-band turn-by-turn rf beam position monitors (BPMs), narrow-band switched heterodyne receivers, and photoemission-style x-ray beam position monitors. Each type of diagnostic has its own set of systematic error effects that place limits on the ultimate pointing stability of x-ray beams supplied to users at the APS. Limiting sources of beam motion at present are magnet power supply noise, girder vibration, and thermal timescale vacuum chamber and girder motion. This paper will investigate the present limitations on orbit correction, and will delve into the upgrades necessary to achieve true sub-micron beam stability.

1998-12-10

214

Endofibrosis of Iliac Arteries in High-Performance Athletes: Diagnostic Approach and Minimally Invasive Endovascular Treatment  

International Nuclear Information System (INIS)

The aim of this article is to report our experience in the diagnosis of two cases of iliac artery endofibrosis or arteriopathy, a rare entity occurring in high-performance athletes, presenting with intermittent claudication (right-sided in both) after maximal exercise. External iliac artery endofibrosis or arteriopathy is a likely diagnosis in competitive athletes free of cardiovascular risk factors who present with leg claudication. Arteriography and a papaverine-assisted mean pressure gradient across the iliac arteries of more than 10 mmHg is a useful diagnostic approach. Moreover, balloon angioplasty of the iliac artery in that patient, in whom a pressure gradient was detected, resulted in symptomatic relief for 2 months followed by mild symptom recurrence. Thus, although balloon angioplasty is feasible and safe, it might not be adequate to treat this entity and, thus, its value remains undefined.

2006-10-01

215

Eddy currents signal processing for steam generator inspection in PWR nuclear power plants  

International Nuclear Information System (INIS)

Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostic system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of these items.

1992-01-01

216

Designing engineering upgradability into magnetic resonance imagers: Impact on future costs  

Energy Technology Data Exchange (ETDEWEB)

MRI is a powerful diagnostic modality of expanding availability. Equipment and installation amount to nearly $2M per site. An important component of diagnostic efficacy is not just equipment costs but also replacement costs, which for x-ray CT amount to 14-20% of the purchase cost per year; and in the early years of that technology reached 30-50%. The authors show how design choices made during the RandD stages of MRI development have allowed them to improve system performance parameters such as data reconstruction, archiving and display speeds, computational capabilities, operator interfaces, imaging sequence flexibility and signal-to-noise levels. Over the last four years these improvements have been made at a retrofit cost well below the target of 6-7% of the purchase price per year.

1987-02-01

217

Cost minimization analysis for combinations of sampling techniques in bronchoscopy of endobronchial lesions  

British Library Electronic Table of Contents (United Kingdom)

SummaryBackground The choice of sampling techniques in bronchoscopy with sampling from a visible lesion will depend on the expected diagnostic yields and the costs of the sampling techniques. Aims The aim of this study was to determine the most economical combination of sampling techniques when approaching endobronchial visible lesions. Methods A cost minimization analysis was performed. All bronchoscopies from 2003 and 2004 at Haukeland university hospital, Bergen, Norway, were reviewed retrospectively for diagnostic yields. 162 patients with endobronchial disease were included. Potential sampling techniques used were biopsy, brushing, endobronchial needle aspiration (EBNA) and washings. Costs were estimated based on registration of equipment costs and personnel costs. Sensitivity analyse...

2009-01-01

218

Application of CaSO4:Dy (TLD-900) to diagnostic x-ray exposures  

International Nuclear Information System (INIS)

The properties of a new commercial thermoluminescent dosimeter, CaSO4:Dy without a LiF binder (TLD-900) was studied for low-exposure measurements in diagnostic radiology. The former TLD-900 had a LiF binder (herein referred to as ''TLD-900/LiF''). The principle features of this dosimeter are its high sensitivity to low-energy radiation and its relatively low fading which permits measurements down to less than 2.6 X 10(-8) C kg (0.1 mR) with an accuracy better than 20%. The characteristics, annealing procedures, light sensitivity, energy response, reproducibility, and fading, of TLD-900 are discussed and compared with TLD-900/LiF. When the precautions presented in this paper are used, the dosimeters can be used for the measurement of x-ray exposures.

219

A method of stereotaxic localization adopted for conventional and digital radiography  

International Nuclear Information System (INIS)

A method for the determination of stereotaxic coordinates in radiography, e.g. angiography, pneumoencephalography or digital vascular radiography, is described. A special localization frame containing radiopaque structures and scales defines a diagnostic coordinate system. This frame is fixed to the X-ray-table prior to the radiographic procedure and two projections are obtained at arbitrary angles to each other. The focus-film distances do not have to be fixed. The target coordinates are then determined either by a simple graphical procedure or with the use of a digitizing x-y-table, by a computer. With the computer method the films are placed on the digitizing table and the target and a few reference points are marked using a cursor. From the relative positions the computer calculates the coordinates. With the special head fixation system, coordinates of structures visualized in radiographic examinations can be transferred to various therapeutic or ...

1986-01-01

220

A comprehensive condition monitoring system for hydro-electric generating units  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a comprehensive MCM [machine condition monitoring] program and suggested system for implementation in hydroelectric generating units. The system addresses all the major subsystems which make up the generating unit. A modular design means that it could be applicable in a wide variety of situations. Different subsystems may be included or excluded from the monitoring system as required. It may be used at individual plants as a stand alone system or network wide. An advanced processing and diagnostic module is included, again for use as an integral part of the system or as a stand alone analysis tool. Examples of the system's proposed data analysis and diagnostic abilities are also described using vibration signals as would be provided by the bearing module. (Author)

1994-04-01

221

A complete census of AGN and their hosts from optical surveys?  

CERN Document Server

Large optical surveys provide an unprecedented census of galaxies in the local Universe, forming an invaluable framework into which more detailed studies of objects can be placed. But how useful are optical surveys for understanding the co-evolution of black holes and galaxies, given their limited wavelength coverage, selection criteria, and depth? In this conference paper I present work-in-progress comparing optical and mid-IR diagnostics of three "unusual" low redshift populations (luminous Seyferts, dusty Balmer-strong AGN, ULIRGs) with a set of ordinary star-forming galaxies from the SDSS. I address the questions: How well do the mid-infrared and optical diagnostics of star formation and AGN strength agree? To what extent do optical surveys allow us to include extreme, dusty, morphologically disturbed galaxies in our "complete" census of black hole-galaxy co-evolution?

2010-01-01

222

[Hormonal disorders in chronic alcoholic intoxication].  

Science.gov (United States)

Hormone levels were examined in the venous blood in 54 men suffering from stage 2 alcoholism and in 30 normal subjects, using a radioimmunochemical assay. The alcoholics were found to have a statistically significant increase in prolactin and a decrease in testosterone. A definite ratio in the secretion of these hormones differing from that in the control group was elucidated. This ratio (prolactin-testosterone index) is proposed as a diagnostic test of alcoholism. PMID:6441404

1984-01-01

223

Uncommon bone tumors of the skull: Ewing's sarcoma and Triton's tumor  

International Nuclear Information System (INIS)

Ewing's sarcoma and Triton's tumor are two uncommon bone tumors of the skull that have nonspecific clinical and imaging features. However, imaging methods are important in the detection of the lesions during the diagnostic investigation in order to evaluate the extent of the bone lesions, involvement of the soft tissues and brain, and to determine the presence of local recurrence and metastases. The confirmatory diagnosis relies on histological studies and immunohistochemistry. The authors report two cases of patients with these tumors and present the radiological findings. (author)

224

Thermal reactor safety  

International Nuclear Information System (INIS)

Information is presented concerning new trends in licensing; seismic considerations and system structural behavior; TMI-2 risk assessment and thermal hydraulics; statistical assessment of potential accidents and verification of computational methods; issues with respect to improved safety; human factors in nuclear power plant operation; diagnostics and activities in support of recovery; LOCA transient analysis; unresolved safety issues and other safety considerations; and fission product transport.

1990-09-01

225

Thermal reactor safety  

Energy Technology Data Exchange (ETDEWEB)

Information is presented concerning new trends in licensing; seismic considerations and system structural behavior; TMI-2 risk assessment and thermal hydraulics; statistical assessment of potential accidents and verification of computational methods; issues with respect to improved safety; human factors in nuclear power plant operation; diagnostics and activities in support of recovery; LOCA transient analysis; unresolved safety issues and other safety considerations; and fission product transport.

1980-06-01

226

The urine test strip of the future.  

Science.gov (United States)

The aim of the classical multiple test strip is to perform routine chemical analysis in one single operation, yielding maximum diagnostic and prognostic information. A maximum of 10 test areas should not be exceeded. The efficiency of the currently marketed test strips is discussed and improvements within acceptable price limits are suggested. PMID:10841930

2000-07-01

227

The scintigraphy of the brain: development, methods and present consequence  

International Nuclear Information System (INIS)

Brain scintiscanning which was first carried out exclusively 'statical' and only with test substances of limited quality has been replaced nowadays by 'dynamical' camera-sequency-scintiscanning with technetium. This brought considerable progress not only for identifying but also for the differential diagnosis of cerebro-organic processes. Development, methods, and integration of brain scintiscanning in a diagnostical conception are described briefly. (orig.).

228

Techniques and tools for condition monitoring and life prediction of fluid power controls used in fuel handling systems of PHWRs  

International Nuclear Information System (INIS)

Various diagnostics techniques for condition monitoring and life prediction of fluid power components and system are discussed. Though some of the techniques are very promising but may not be accepted because of increase in the instrumentation, it is planned to implement these techniques on various circuits of Fluid Power Lab for further improving and developing these for direct implementation in various fluid power circuits of power reactors. (author). 6 figs.

229

Spot size and Guoy phase invariant telescope for auto-alignment of resonant cavities  

International Nuclear Information System (INIS)

We present both the theory and an experimental method to accurately set up a Guoy phase telescope, where both the output spot size and orthogonality condition are invariant to distance from the cavity beam waist. We demonstrate that Gaussian spot size measurements can be used as a diagnostic to determine the desired locations of split area photodetectors. The Guoy phase invariance is verified using the tilt-locking technique.

2004-03-07

230

Spectroscopic study of some historical arts  

International Nuclear Information System (INIS)

This work presents the spectroscopic results of the investigations of ancient pottery remains excavated in ancient Kremna (BURDUR-TURKEY). The micro-Raman and FT-IR spectroscopic studies of the pottery remains belonging to sixth century allowed us to identify the mineral composition. Some examples are described of the use of this technique in the field of art conservation and diagnostics, with regard to pigments, and some products of metal alteration.

2009-09-24

231

Signal processing methods for MFE plasma diagnostics  

Energy Technology Data Exchange (ETDEWEB)

The application of various signal processing methods to extract energy storage information from plasma diamagnetism sensors occurring during physics experiments on the Tandom Mirror Experiment-Upgrade (TMX-U) is discussed. We show how these processing techniques can be used to decrease the uncertainty in the corresponding sensor measurements. The algorithms suggested are implemented using SIG, an interactive signal processing package developed at LLNL.

1985-02-01

232

Screen-film-combinations for radiography - present and future spectrum of application  

Energy Technology Data Exchange (ETDEWEB)

From the numbers of radiographs of the different examinations and the total amount of radiological diagnostics in the GDR their possible modification by new imaging techniques is discussed under the aspects of costs and radiation burden. Film-screen-systems are of special importance, because they also will be most frequently used image recording system in future. The importance of their various properties and parameters, methods of determining these parameters as well as future developments are analyzed from the standpoint of practical requirements.

1985-01-01

233

Screen-film-combinations for radiography - present and future spectrum of application  

International Nuclear Information System (INIS)

From the numbers of radiographs of the different examinations and the total amount of radiological diagnostics in the GDR their possible modification by new imaging techniques is discussed under the aspects of costs and radiation burden. Film-screen-systems are of special importance, because they also will be most frequently used image recording system in future. The importance of their various properties and parameters, methods of determining these parameters as well as future developments are analyzed from the standpoint of practical requirements. (author).

234

Roentgenologic appearance of a thorotrast-induced small cholangiocarcinoma in a case of thorotrastosis  

International Nuclear Information System (INIS)

A small cholangiocarcinoma was detected at autopsy in a patient with thorotrastosis who died from the rupture of esophageal varices at the esophagogastric junction. Prior to the advent of recent diagnostic imaging technique, a correct antemortem diagnosis could only be obtained from tumor markers. However, the tendency for the opacity of the liver to decrease slowly with time and develop uneven trabeculation suggests that small tumors may be difficult to detect against such a non-homogeneous background. (author).

235

Researches on Plasma Physics and Controlled Fusion in IPP NSC KIPT  

International Nuclear Information System (INIS)

Recent results of experimental and theoretical investigations, carried out in the Institute of plasma Physics of the NSC KIPT, are presented in the report. The main problems of discussion are as follows: plasma confinement and heating in stellarators and electromagnetic traps; powerful quasi-steady-state plasma accelerators (QSPA); experiments relevant for ITER; fusion Plasma theory; methods of high temperature plasma diagnostics; plasma technology. The main prospects on the IPP investigators are discussed also.

2006-01-01

236

Reliability of diagnostic imaging techniques in suspected acute appendicitis: proposed diagnostic protocol; Indicacion de las tecnicas de diagnostico por la imagen en la sospecha de apendicitis aguda: propuesta de protocolo diagnostico  

Energy Technology Data Exchange (ETDEWEB)

To study the utility of ultrasound and computed tomography (CT) in case of suspected appendicitis. To determine the diagnostic yield in terms of different clinical contexts and patient characteristics. to assess the costs and benefits of introducing these techniques and propose a protocol for their use. Negative appendectomies, complications and length of hospital stay in a group of 152 patients with suspected appendicitis who underwent ultrasound and CT were compared with those of 180 patients who underwent appendectomy during the same time period, but had not been selected for the first group: these patients costs for each group were calculated. In the first group, the diagnostic value of the clinical signs was also evaluated. The reliability of the clinical signs was limited, while the results with ultrasound and CT were excellent. The incidence of negative appendectomy was 9.6% in the study group and 12.2% in the control group. Moreover, ...

2001-07-01

237

Reference values for X-ray diagnostic investigations. Some thoughts on the relation between expenditure and benefit  

International Nuclear Information System (INIS)

In the first part of this contribution, the definition of reference values is given and the theoretical and practical problems in the application of this concept are discussed. In this connection, the present resources on instrumentation and the technical requirements for dose assessment are described. In the second part, some consequences are taken and proposals for further actions are made. (orig.)

238

Radiation hazards from medical applications  

International Nuclear Information System (INIS)

An introduction is presented on the radiation hazards connected with biomedical radiography and nuclear medicine. The frequency of radiodiagnostic efforts was rather high in the Netherlands. This was reduced considerably by abolishing the thorax screening of the population. About diagnostic nuclear medicine less can be said because far fewer numerical data are available. An exposition of genetically and somatically significant doses and how to compute them is given. The drawing up of a profit versus risk evaluation for medical applications of ionizing radiations is recommended. (Auth.).

1980-05-31

239

Radiation exposure of the population of the GDR by X-ray diagnostics  

International Nuclear Information System (INIS)

The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.

1986-01-01

240

Possibilities of rayleigh-taylor instability measurement by X-ray phase imaging  

International Nuclear Information System (INIS)

X-ray imaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging

241

Plasma-optic separation and diagnostics results of division spent nuclear fuel  

International Nuclear Information System (INIS)

The possibility of separation in plasma-mass-separator POMS-E-3 spent nuclear fuel (SNF) in 3 fractions: transuranic elements, and two groups of fission products. New scheme of compact energy-mass analyzer for monitoring the separation process spent nuclear fuel in the POMS-E- 3 offered.

242

Patient doses from medical uses of x-rays  

International Nuclear Information System (INIS)

A survey to determine the annual genetically significant dose and mean bone-marrow dose to the Australian population from radiological procedures has been undertaken. For diagnostic radiology the following were carried out: determination of the frequency of a procedure; measurement of patient doses using TLD and processing of data and calculation of gonadal and bone-marrow doses.

1981-01-01

243

Optimizing Antigen Cocktails for Detection of Mycobacterium bovis in Herds with Different Prevalences of Bovine Tuberculosis: ESAT6-CFP10 Mixture Shows Optimal Sensitivity and Specificity?  

UK PubMed Central (United Kingdom)

Bovine tuberculosis is a major problem in many countries; hence, new and better diagnostic tools are urgently needed. In this work, we have tested ESAT6, CFP10, PE13, PE5, MPB70, TB10.4, and TB27.4...Full Text Available

2006-12-01

244

Optical diagnostics based on elastic scattering: Recent clinical demonstrations with the Los Alamos Optical Biopsy System  

Energy Technology Data Exchange (ETDEWEB)

A non-invasive diagnostic tool that could identify malignancy in situ and in real time would have a major impact on the detection and treatment of cancer. We have developed and are testing early prototypes of an optical biopsy system (OBS) for detection of cancer and other tissue pathologies. The OBS invokes a unique approach to optical diagnosis of tissue pathologies based on the elastic scattering properties, over a wide range of wavelengths, of the microscopic structure of the tissue. The use of elastic scattering as the key to optical tissue diagnostics in the OBS is based on the fact that many tissue pathologies, including a majority of cancer forms, manifest significant architectural changes at the cellular and sub-cellular level. Since the cellular components that cause elastic scattering have dimensions typically on the order of visible to near-IR wavelengths, the elastic (Mie) scattering properties will be strongly wavelength ...

1993-08-01

245

New techniques of power transformers monitoring and diagnostic; Novas tecnicas de monitoramento e diagnostico de transformadores de potencia  

Energy Technology Data Exchange (ETDEWEB)

This article describes the techniques for monitoring electric power transformers applied by the Light to select and recover critical unities. The plan involved 20 and 40 MV A equipment and, as a reflex of the technique application, presented a substantial failure reduction.

2003-04-01

246

New concept to optimize emergency diagnoses in patients with multiple injuries  

International Nuclear Information System (INIS)

To optimize the emergency care of patients with multiple injuries, a special emergency room with integrated radiological equipment has been developed. It consists of a linear array of a computed tomography system, a mobile C-arm with an integrated scattered radiation grid for conventional films and a C-arm fluorographic system. The intent is to avoid delay caused by transport and repositioning of the patient. It enables all necessary diagnostic procedures to be performed within a minimal amount of time. (orig./MG).

247

Modularity for bio business growth  

British Library Electronic Table of Contents (United Kingdom)

Interchangeable technology from Flexicon Liquid Filling, a business division of Watson-Marlow Pumps Group, has helped family-run diagnostic reagent manufacturer, Hart Biologicals Ltd, to accommodate business growth with the recent upgrade to a tabletop bottle filling and capping machine. A peristaltic dispensing pump is crucial for succes

2011-01-01

248

Modeled Neutron Induced Nuclear Reaction Cross Sections for Radiochemistry in the region of Iridium and Gold  

International Nuclear Information System (INIS)

We have developed a set of modeled nuclear reaction cross sections for use in radiochemical diagnostics. Systematics for the input parameters required by the Hauser-Feshbach statistical model were developed and used to calculate neutron induced nuclear reaction cross sections for targets ranging from osmium (Z = 76) to gold (Z = 79). Of particular interest are the cross sections on Ir and Au including reactions on isomeric targets.

2008-02-01

249

Machine condition monitoring  

Energy Technology Data Exchange (ETDEWEB)

A consortium has been formed to undertake the design and development work necessary to establish a comprehensive machine condition monitoring (MCM) and diagnostic system for hydroelectric generating units. By working closely with participating utilities and interested manufacturers, the consortium is initiating the integration of existing and developing technologies into a comprehensive, modular, on- and off-line hydroelectric MCM system.

1995-12-31

250

Lung studies with spiral CT. pitch 1 versus pitch 2  

International Nuclear Information System (INIS)

In Spiral CT, the pitch is the ratio of the distance to tabletop travels per 360 degrees rotation to nominal slice width, expressed in mm. Performing Spiral CT examination with pitch 2 allows to reduce examination time, exposure and contrast dose, and X-ray tube overload. The authors investigated the yield of pitch 2 in lung parenchyma studies, particular relative to diagnostic image quality.

1999-03-01

251

Life time management at the Dukovany nuclear power plant  

International Nuclear Information System (INIS)

The paper discusses the role of the Life Management Programme in ensuring a safe operation of the Dukovany nuclear power plant. The Programme involves the following major items: (i) primary circuit materials degradation assessment, (ii) pipeline damage control by the Flow Assisted Corrosion Monitoring and Prediction Programme, and (iii) the DIALIFE diagnostic system. (author)

252

Instrumentation and control improvements at Experimental Breeder Reactor II  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to describe instrumentation and control (I C) system improvements at Experimental Breeder Reactor 11 (EBR-11). The improvements are focused on three objectives; to keep the reactor and balance of plant (BOP) I C systems at a high level of reliability, to provide diagnostic systems that can provide accurate information needed for analysis of fuel performance, and to provide systems that will be prototypic of I C systems of the next generation of liquid metal reactor (LMR) plants.

1993-01-01

253

Instrumentation and control improvements at Experimental Breeder Reactor II  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to describe instrumentation and control (I&C) system improvements at Experimental Breeder Reactor 11 (EBR-11). The improvements are focused on three objectives; to keep the reactor and balance of plant (BOP) I&C systems at a high level of reliability, to provide diagnostic systems that can provide accurate information needed for analysis of fuel performance, and to provide systems that will be prototypic of I&C systems of the next generation of liquid metal reactor (LMR) plants.

1993-03-01

254

Increased renal corticomedullary FDG activity in a patient of NHL-malignant or benign?  

International Nuclear Information System (INIS)

Authors describe diagnostic dilemma of differentiating pyelonephritis with lymphomatous involvement of kidney in a known case of lymphoma. FDG uptake pattern was non-discriminatory and pyelonephritis diagnosed retrospectively on follow up study. Authors emphasize the importance of recognition of features and subtle clues of infection evident on CT component of PET-CT. (author)

255

Importance of computer tomography in paediatric diagnostics of abdominal and pelvic tumours  

Energy Technology Data Exchange (ETDEWEB)

In a joint study conducted by the University Clinic of Radiology, Graz, and the Medical University Clinic, Innsbruck, the results of computer tomography examinations of the abdomen and pelvis in 23 cases of tumours in children are discussed. In children computer tomography resents special difficulties on account of the very poorly developed fatty layers between the organs and the increased incidence of movement artifacts. The importance of computer tomography for the diagnosis of abdominal and pelvic tumours is discussed.

1980-03-01

256

High-End CT for clinical and scientific applications; High-End-CT im klinischen und wissenschaftlichen Einsatz  

Energy Technology Data Exchange (ETDEWEB)

The enhancements described of high-performance CT systems of latest design have again confirmed the importance of CT systems for acute and selective diagnostic imaging. Higher availability, shorter exposure times, and better applicability and handling for examination of poly-traumata patients or patients of intensive care departments are some of the advantages achieved with CT systems which demonstrate CT system efficiency in addition to MRI, which for specific examinations will remain the modality of first choice for diagnostic evaluation. The Tomoscan Av-E presented here was able to answer all relevant diagnostic questions appearing in routine diagnostics and scientific work. For patients, examinations using the spiral CT technique also offers significant advantages. (orig./CB) [Deutsch] Durch die dargestellten Verbesserungen bei Hochleistungs-CT-Systemen neuester Bauart wurde die Bedeutung der CT ...

1997-12-01

257

Genetic and somatic risks in X-ray diagnosis  

International Nuclear Information System (INIS)

Based on a literature study an actual summary of the risk-utility problems in X-ray diagnosis is outlined due to the Recommendations of the International Commission for Radiation Protection (ICRP publication 26/1977). Papers demonstrating quantitative assessment of the somatic and genetical risk in X-ray examination are preferably cited and evaluated. It is concluded that the somatic and genetical risk is low in diagnostic ratiology. However, it must not be neglected and has always to be compared to the utility of an examination as well as to other risks of the examination. (author).

1982-01-01

258

Gastrin releasing peptide (GRP) receptor targeted radiopharmaceuticals: A concise update  

Energy Technology Data Exchange (ETDEWEB)

The gastrin releasing peptide (GRP) receptor is becoming an increasingly attractive target for development of new radiolabeled peptides with diagnostic and therapeutic potential. The attractiveness of the GRP receptor as a target is based upon the functional expression of GRP receptors in several tumors of neuroendocrine origin including prostate, breast, and small cell lung cancer. This concise review outlines some of the efforts currently underway to develop new GRP receptor specific radiopharmaceuticals by employing a variety of radiometal chelation systems.

2003-11-01

259

First Outbreak of Multidrug-Resistant Klebsiella pneumoniae Producing both SHV-12-Type Extended-Spectrum ?-Lactamase and DHA-1-Type AmpC ?-Lactamase at a Korean Hospital  

UK PubMed Central (United Kingdom)

PurposeCoexistence of different classes of β-lactamases in a single bacterial isolate may pose diagnostic and therapeutic challenges. We investigated a spread of Klebsiella...Full Text Available

2008-02-29

260

Ewing's sarcoma of the sacrum  

International Nuclear Information System (INIS)

A lytic lesion with softtissue extension in the sacrum of a 47-year old man was needle-biopsied under computed tomographic (CT) guidance using an 18-gauge cutting needle. The cytologic appearance of the lesion and immunohistochemical staining were diagnostic of Ewing's sarcoma. Specifically, a new marker (O13) for the presence of glycoprotein p30/32 mic2 in Ewing's sarcoma was utilized. (orig.).

261

Evaluation of the rapid diagnostic test SDFK40 (Pf-pLDH/pan-pLDH) for the diagnosis of malaria in a non-endemic setting  

UK PubMed Central (United Kingdom)

BackgroundThe present study evaluated the SD Bioline Malaria Ag 05FK40 (SDFK40), a three-band RDT detecting Plasmodium falciparum-specific parasite lactate dehydrogenase...Full Text Available

262

Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOVA test. The mean ROC areas of conventional radiography, ...

2003-03-15

263

Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries  

International Nuclear Information System (INIS)

The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOVA test. The mean ROC areas of conventional radiography, ...

2003-03-01

264

Emission-Line versus Continuum Correlations in Active Galactic Nuclei  

CERN Document Server

The Baldwin Effect, a negative correlation between emission-line equivalent width and luminosity in active galactic nuclei, is still of interest as a diagnostic of accretion physics nearly thirty years after its discovery. This review examines recent developments in the study of correlations between line and continuum emission in AGNs, as measured both in ensembles and in individual sources.

2006-01-01

265

Differential optical absorption techniques for diagnostics of coal gasification. Technical progress report, October, November, December 1982  

Energy Technology Data Exchange (ETDEWEB)

The application of differential optical absorption (DOA) techniques for the in-situ determination of the chemical composition of coal gasification process streams is investigated. Absorption spectra of relevant molecular species and the temperature and pressure effects on DOA-determined spectral characteristics of these species will be determined and cataloged. A system will be configured, assembled, and tested.

1983-04-01

266

Diagnostic value of immediate CT after chemoembolization in patients with hepatocellular carcinoma: comparison with 2-3 week delayed CT  

Energy Technology Data Exchange (ETDEWEB)

Lipiodol CT is a important modality for the diagnosis of hepatocellular carcinoma and compared is usually performed at 2-3 week after Lipiodol injection. Therefore, we assessed and the diagnostic value and merits of immediate CT after chemoembolization from there of 2-3 week delayed Lipiodol CT. Thirty three cases of chemoembolization which were performed both immediate CT after chemoembolization and 2-3 week delayed Lipiodol CT were reviewed retrospectively. They were divided into four grades according to pattern of lipiodol uptake by three radiologists. The diagnostic value of immediate Lipiodol CT was compared to delayed Lipiodol CT. Grade 0 was two cases(3.0%) and Grade 1 was seven cases(21.2%). In the cases of Grade 2(23/33, 69.7%), tumor uptake could be dishing wished from parenchymal uptake of Lipiodol by its density and pattern, Tumor uptake showed dense and homogeneous pattern, but parenchymal uptake revealed less dense and ...

1995-08-15

267

Diagnostic measurements on the great machines conditions of lignite surface mines  

Science.gov (United States)

An analysis of the diagnosis of loading and service dependability of a rail-mounted excavator used in surface lignite mining is described. Wheel power vibrations in electric motor bearings and electric motor input bearings to the gearbox were measured in situ, in horizontal, vertical, and axial directions. The data were analyzed using a mathematical relationship. The results are presented in a loading diagram that shows the deterioration and the acceptable lower bound of machine conditions over time. Work is continuing. 5 refs., 1 fig.

2005-07-01

268

Detection of aortoarterial graft infections by leukocyte scintigraphy  

Energy Technology Data Exchange (ETDEWEB)

Infections of aortoarterial prostheses are serious, difficult to detect, and difficult to treat. Scintigraphy with indium-111 labeled autologous leukocytes is an accurate noninvasive method of assessing the presence and extent of such an infection. In three cases of aorto-arterial bypass graft infections, the leukocyte study was successful in establishing the diagnosis and in assessing the extent of infection. Other noninvasive diagnostic techniques are useful, but all have serious limitations. The leukocyte study alone appears to be free of likely sources of error.

1983-09-01

269

Current diagnosis of tumors developed in the internal auditory canal and cerebellopontine angle  

Energy Technology Data Exchange (ETDEWEB)

The introduction of CT scan and, more recently, magnetic resonance imaging, has radically changed the diagnostic approach to tumors developed in the internal auditory canal and cerebellopontine angle. CT scan with intravenous injection visualizes tumors lying in the cerebellopontine angle. Magnetic resonance imaging, especially using gadolinium, is a very accurate means for diagnosing tumors of both the auditory canal and cerebellopontine angle.

1988-10-13

270

Current Status on Stress Diagnostic Kit and Detection Technology  

Energy Technology Data Exchange (ETDEWEB)

The accurate measurement of a stress level is one of the most important issues in a stress diagnosis and its measurement could be of great value in clinical medicine. Stress has a potent effect on the spirit and physical condition of an individual. There are various methods available for its measurement. Some of the commonly used techniques for the diagnosis of a stress level include analysis of the body fluids, questionnaire assessments, psychophysiological evaluations and by determining heart rate variability (HRV) of subjects. However, the existing diagnostic methods have several defects like, a low sensitivity, inaccuracy and long of operation time. In this report, we present a diagnostic technology to detect a stress level which is the origin of various diseases. This method can be of great help in providing an early diagnosis through a biosensor and might play a vital role in preventing diseases like hypochondria and hypertension. ...

2008-06-15

271

Concentration and Preservation of Very Low Abundance Biomarkers in Urine, such as Human Growth Hormone (hGH), by Cibacron Blue F3G-A Loaded Hydrogel Particles  

UK PubMed Central (United Kingdom)

Urine is a potential source of diagnostic biomarkers for detection of diseases, and is a very attractive means of non-invasive biospecimen collection. Nonetheless, proteomic measurement in urine...Full Text Available

2008-12-01

272

Computer tomography of orbita in children  

Energy Technology Data Exchange (ETDEWEB)

The experiences are described of the examination of orbita in children using computer tomography (CT). Over a period of four years 42 examinations were performed of children in the age ranging between 7 months and 15 years, i.e., 2.7 percent of all CT examinations performed. The highest diagnostic yield was in orbita tumours. The possibilities of CT are demonstrated on examples.

1983-07-01

273

Comprehensive, nonintercepting electron-beam diagnostics using spontaneous emission  

Energy Technology Data Exchange (ETDEWEB)

Characterization and optimization of electron-beam parameters are important aspects of optimizing free-electron laser (FEL) performance. The visible spontaneous emission ({lambda}{approximately}650 nm) from the 5-meter long undulator of the Boeing FEL experiment can be characterized in sufficient detail with a streak/spectrometer to deduce time-resolved electron-beam spatial position and profile, micropulse duration, and energy. 7 refs., 13 figs., 2 tabs.

1989-01-01

274

Commercially Available Antibodies to Human Tumour Necrosis Factor-? Tested for Cross-Reactivity with Ovine and Bovine Tumour Necrosis Factor-? using Flow Cytometric Assays  

UK PubMed Central (United Kingdom)

A thorough understanding of the immune system, including the role of different cytokines, during inflammatory diseases in ruminants could lead to the development of new diagnostic methods and treatments....Full Text Available

2004-01-01

275

Clinical application of FCR for the portable chest radiographs in ICU  

Energy Technology Data Exchange (ETDEWEB)

The diagnostic value of the portable chest radiography obtained with Fuji computed radiography (FCR) was evaluated in comparison with conventional images in 23 patients who were admitted to ICU in Yokohama City University Hospital. On the whole , FCR produced more exellent images than conventional screen-film radiographs. Especially the evaluation for the demonstration of the catheters, the endotracheal tubes and the tracheal shadows obtained high score. We discuss the clinically utility of FCR for the portable chest radiographs in ICU. (author).

1989-08-01

276

Clinical application of FCR for the portable chest radiographs in ICU  

International Nuclear Information System (INIS)

The diagnostic value of the portable chest radiography obtained with Fuji computed radiography (FCR) was evaluated in comparison with conventional images in 23 patients who were admitted to ICU in Yokohama City University Hospital. On the whole , FCR produced more exellent images than conventional screen-film radiographs. Especially the evaluation for the demonstration of the catheters, the endotracheal tubes and the tracheal shadows obtained high score. We discuss the clinically utility of FCR for the portable chest radiographs in ICU. (author).

1989-01-01

277

Clinical Procedures for Medical Technology Specialists  

CERN Document Server

Divided into diagnostic and treatment sections, this book provides a comprehensive overview of the most common medical procedures performed in modern clinical settings. Each section presents common names for the procedure; an outline of the disease or injury for which the procedure is performed; a brief review of the anatomical structures and physiological processes that are involved; staffing, equipment, and pre-procedure requirements; a detailed description of the procedure itself; and, a discussion of expected outcomes as well as potential complications. Each chapter includes a summary and

2010-01-01

278

Biological parameters of transgenic rabbits  

British Library Electronic Table of Contents (United Kingdom)

The investigations were conducted at the Center of Biotechnology and Molecular Diagnostics of the All-Russian Animal Husbandry Research Institute, where a number of valuable transgenic animals (rabbits, sheep, and pigs) have been produced over the course of 20 years. The article presents the blood indices of control and transgenic rabbits with an integrated insulin gene.

2011-01-01

279

Application of coherent lidar to ion measurements in plasma diagnostics  

Energy Technology Data Exchange (ETDEWEB)

A coherent lidar system has been constructed for the measurement of alpha particles in a burning plasma. The lidar system consists of a pulsed CO{sub 2} laser transmitter and a heterodyne receiver. The receiver local oscillator is a cw, sequence-band CO{sub 2} laser operating with a 63.23 GHz offset from the transmitter.

1997-03-01

280

Amp-PCR: Combining a Random Unbiased Phi29-Amplification with a Specific Real-Time PCR, Performed in One Tube to Increase PCR Sensitivity  

UK PubMed Central (United Kingdom)

In clinical situations where a diagnostic real-time PCR assay is not sensitive enough, leading to low or falsely negative results, or where detection earlier in a disease progression would benefit the...Full Text Available

281

Advances in noise analysis for nuclear plant surveillance and diagnostics  

Energy Technology Data Exchange (ETDEWEB)

An automated surveillance and baseline noise signature acquisition system is being demonstrated at Sequoyah-1. A nonperturbing method is also being developed for monitoring the subcritical reactivity during initial core loading in LWRs, in fuel storage and processing facilities, and during postaccident recovery operations such as Three Mile Island-2. (DLC)

1980-01-01

282

A radiant temperature numerical method for laser-plasma diagnostic using SXRSC with absorption method  

International Nuclear Information System (INIS)

An numerical method was developed for measuring radiant temperature using a set of absorption-foils coupled to soft x ray streak camera, SXRSC, in laser plasma experiments. An numerical code, SCC, was given. An x-ray intensity ratio vs temperature was calculated for Parylene, C_3H_6, Mylar and Aluminium. A suitable range of the measuring temperature was discussed to some absorber.

1990-01-01

283

Review of JT-60U experimental results from February to October, 1999  

International Nuclear Information System (INIS)

In 1999, the plasma parameters of reversed shear (RS) plasmas had been extended in 1) DT-equivalent fusion power gain Q_D_T"e"q - 0.5 (n_D(0)#tau#_ET_i(0) - 4x10"2"0 m"-"3#centre dot#keV#centre dot#s) for 0.8 s and 2) full non-inductive current drive with 80% of the bootstrap current fraction. Physics of the internal transport barriers (ITBs) in RS plasmas, including the energy transport and the formation of ITB, were extensively studied. A nearly full current drive (92% non-inductively) was obtained with negative ion based neutral beam (NNB) injection (360 keV, 3.4 MW) in a high #beta#_p H-mode plasma (I_p=1.5 MA, B_T=3.7 T, q_9_5=4.2) with high plasma performance (#beta#_N=2.4 and H_8_9=2.56). Rise in the central electron temperature (T_e - 9 keV) resulted in the current drive efficiency #eta#_C_D of NNB reached 1.3x10"1"9 A/W/m"2, the highest for the neutral beam current drive. As for the H-mode plasmas, decrease in the pedestal ion temperature due to strong gas was found cause ...

1994-06-01

284

[Differential diagnosis and prognosis of phobic disorders].  

Science.gov (United States)

The paper presents differential-diagnostic signs of phobic disorders of different etiology. Acute episodes of depersonalization preceding phobias and fears arising during the first age crisis are considered as some diagnostic signs of endogenous phobias. The significant criteria for diagnosis of psychogenic phobias are anxious suspiciousness, affective instability, susceptibility, spontaneity of reactivity and the presence of personally important psychic trauma. An autonomic paroxysm caused by alcoholic situation in exogenic organic pathology (alcoholism) was transformed quite fast into some senestopathias, which themselves maintained the of fear. The relationships of phobias and depressions in endogenous disorders was different: in slow-progredient variations of the disease depression resulted in a decrease of the manifestations of the phobias, and vice versa; in shift-like variations depression is an independent syndrome in the ...

1998-01-01

285

Xeroradiography and computed radiography comparative study on diagnosis for breast cancer  

Energy Technology Data Exchange (ETDEWEB)

Xeroradiography (XR) was retrospectively compared with a newly developed computed radiography (FCR) for diagnostic availability for breast cancer. FCR provides with the image processed by a computer. Subjects were 65 breast cancer patients for XR and 51 for FCR. Both methods were performed preoperatively. No significant difference was observed in distribution of age between the two groups but the average tumor size in XR group was larger than that in FCR group. Tumor shadow appeared in 44 of 65 xeromammograms (67.7%) and in 34 of 51 computed radiograms (66.7%). Microcalcification was detected in 27 of 65 xeromammograms (41.5%) and in 21 of 51 computed radiograms (41.2%). Consequently, diagnosis of breast cancer could be achieved in 47 of 65 patients (72.3%, established: 39, suspective: 8) through XR and in 41 of 51 (80.4%, established: 33, suspected: 8) through FCR. Thus FCR is thought to be more useful for breast cancer because it not only offers good ...

1990-04-01

286

Xeroradiography and computed radiography comparative study on diagnosis for breast cancer  

International Nuclear Information System (INIS)

Xeroradiography (XR) was retrospectively compared with a newly developed computed radiography (FCR) for diagnostic availability for breast cancer. FCR provides with the image processed by a computer. Subjects were 65 breast cancer patients for XR and 51 for FCR. Both methods were performed preoperatively. No significant difference was observed in distribution of age between the two groups but the average tumor size in XR group was larger than that in FCR group. Tumor shadow appeared in 44 of 65 xeromammograms (67.7%) and in 34 of 51 computed radiograms (66.7%). Microcalcification was detected in 27 of 65 xeromammograms (41.5%) and in 21 of 51 computed radiograms (41.2%). Consequently, diagnosis of breast cancer could be achieved in 47 of 65 patients (72.3%, established: 39, suspective: 8) through XR and in 41 of 51 (80.4%, established: 33, suspected: 8) through FCR. Thus FCR is thought to be more useful for breast cancer because it not only offers good ...

1990-01-01

287

Virtual colonoscopy (CT colonography) in the identification of colorectal cancer. A prospective study in symptomatic patients  

International Nuclear Information System (INIS)

Aim of this study was to evaluate the sensitivity of virtual colonoscopy (CT colonography) in the identification of colorectal cancer and to define the limitations and the advantages of this imaging modality, as well as indications to the examination. It was examined prospectively 62 symptomatic patients aged 36 to 82 years (28 women and 34 men). All patients underwent both conventional and virtual colonoscopy on the same day; the conventional examination allowed exploration of the entire colon. Conventional colonoscopy identified 89 lesions 3-50 mm in diameter, namely 84 benign and 5 malignant lesions. No lesions were identified in 12 patients. CT colonography identified 52 of the 89 lesions, with 57.1% diagnostic accuracy. They were 11 false positives (82.5% positive predictive value and 52.2% specificity) and 37 false negatives (24.5% negative predictive value and 58.4% sensitivity). Sensitivity was significantly higher (85.7%) for polyps #>=# 1 cm. Virtual ...

2000-06-01

288

Ultrasonography and Computerized Tomography in the diagnosis of complex abdominal lesions  

International Nuclear Information System (INIS)

Complex abdominal lesions include a variety of pathologies, such as septated, infected, and hemorrhagic cysts, abscesses, tumors, and fluid collections of different ethiology. These lesions present diagnostic difficulties with both Ultrasonography (US) and Computed Tomography (CT), since findings may not be present or, when present, are not specific. Keeping these limitations in mind, we evaluated 105 patients (111 abdominal lesions) with both US and CT in order to compare their adequacy in predicting the nature of the lesion. On the basis of US and CT results, complex abdominal lesions were divided in four classes: class I includes 43 cases in which both examinations gave the same contribution to the definition of the nature of the lesion, class II (14 lesions, mainly sperimentated cysts), in which US was superior to CT, class III includes 45 cases of hemorrhagic cysts, abscesses, fluid collections and, less frequently, cystic tumors; class IV includes 9 cases in ...

1988-01-01

289

Transient data acquisition techniques under EDS  

Energy Technology Data Exchange (ETDEWEB)

This paper is the first of a series which describes the Enrichment Diagnostic System (EDS) developed for the MARS project at Lawrence Livermore National Laboratory. Although EDS was developed for use on AVLIS, the functional requirements, overall design, and specific techniques are applicable to any experimental data acquisition system involving large quantities of transient data. In particular this paper will discuss the techniques and equipment used to do the data acquisition. Included are what types of hardware are used and how that hardware (CAMAC, digital oscilloscopes) is interfaced to the HP computers. In this discussion the author will address the problems encountered and the solutions used, as well as the performance of the instrument/computer interfaces. The second topic the author will discuss is how the acquired data is associated to graphics and analysis portions of EDS through efficient real time data bases. This discussion will include how the ...

1985-06-01

290

The use of "1"3"1I-radioiodine in diagnostic and treatment: estimated risk in Guanabara  

International Nuclear Information System (INIS)

The "1"3"1-radioiodine use in Guanabara area, during 1972-1973, is analysed. References are made to the radiation levels delivered to thyroid, bone marrow and gonads in a population of 27000 people examined by tracer techniques, 190 submitted to hyperthyroidism treatment and 50 treated for thyroid cancer. The pertinent literature gives some data concerning radiation induced cancer (leukaemia and thyroid cancer). By this, it was possible to estimate the probability of tumour occurrence in that population, assuming a linear relationship between dose and effect. The conclusions are the followings: 1 - there are many duties in this field at the present; 2 - the leukaemia incidence related to the 131-radioiodine use is negligible, either in diagnostic or therapeutic modalities; 3 - the possibility of thyroid tumors induced by radiation is real, specially in hyperthyroidism treatment; 4 - the use of tracer techniques that cause lower irradiation to the pacient is ...

291

The somatically significant dose, SSD, and analog of the GSD, the genetically significant dose  

International Nuclear Information System (INIS)

The medical applications of radiation comprise three main fields namely: Diagnostic Radiology, Radiotherapy and Nuclear Medicine. With the new weighting factors of ICRP (IC91a) the effective dose due to medical applications can be established. I is common to separate the effective dose into the genetic part and the somatic part, SED. In dealing with gonad doses it is important to account for the age of the person at the time of exposure as this will influence the number of children still to be expected from that person. The resulting dose will then be called the genetically significant dose, GSD. In a similar fashion this age factor will be important in considering the chance of tumor induction. The age of patients differs considerably from the average age of the general population. This age difference has to be accounted for if a comparison is to be made with other sources of radiation. This justifies establishing a somatically significant dose, SSD. The reduction ...

1991-11-01

292

The Kinematic Signature of Face-On Peanut-Shaped Bulges  

CERN Document Server

We present a kinematic diagnostic for peanut-shaped bulges in nearly face-on galaxies. The face-on view provides a novel perspective on peanuts which would allow study of their relation to bars and disks in greater detail than hitherto possible. The diagnostic is based on the fact that peanut shapes are associated with a flat density distribution in the vertical direction. We show that the kinematic signature corresponding to such a distribution is a minimum in the fourth-order Gauss-Hermite moment $s_4$. We demonstrate our method on $N$-body simulations of varying peanut strength, showing that strong peanuts can be recognized to inclinations $i \\simeq 30\\degrees$, regardless of the strength of the bar. We also consider compound systems in which a bulge is present in the initial conditions as may happen if bulges form at high redshift through mergers. We show that in this case, because the vertical structure of the bulge is not derived from ...

2005-01-01

293

Steady-state passive films; Interfacial kinetic effects and diagnostic criteria  

Energy Technology Data Exchange (ETDEWEB)

This paper reports that the point defect model for steady-state passive films formed anodically on metal s in aqueous environments has been extended to include irreversible dissolution of the film and the irreversible generation and annihilation of cation and oxygen vacancies at the metal/film and film/solution interfaces. THe model yields a number of diagnostic criteria that can be used to identify the majority (vacancy) charge carrier and to characterize the kinetic nature of the interfacial vacancy generation and annihilation processes. We use these criteria to show that the steady-state passive film that forms on nickel in acidic phosphate buffer solutions is a cation conductor and that cation transport from the metal to the solution involves irreversible ejection of cations from the film. On the other hand, the passive film that forms on tungsten in the same environment under steady-state conditions is found to be an oxygen ion conductor with the passive ...

1992-01-01

294

Regulatory requirements for design of safety related computer based control Systems in Indian PHWRs: case study of DPHS-PCS for TAPP-3 and 4  

International Nuclear Information System (INIS)

Computer based control systems for safety related applications in nuclear power plants have to meet not only the functional, performance and interface requirements, they in addition, have to meet regulatory requirements like enhanced reliability, safety and security and should provide fault tolerance, diagnostics and self-supervision. The control system architecture, hardware design and software design should meet requirements as specified in design code and guides of AERB. The Dual Processor Hot Standby Process Control System (DPHS-PCS) for TAPP-3 and 4 is a safety related (Class- IB) system. DPHS-PCS regulates PHT pressure, Pressuriser pressure, Pressuriser level, Bleed condenser pressure, Bleed condenser level and Steam generator pressure. The performance, reliability and safety requirements of this control system are met by employing a fault tolerant computer configuration developed for this purpose using hardware designed with facility for on-line ...

2005-03-01

295

Pelvic CT for the prognostic evaluation of anorectal malformation  

International Nuclear Information System (INIS)

The anatomical patterns of anorectal malformations have so far been studied according to the principles which inspire Pena's technique for the surgical treatment of anorectal anomalies. Thus, the diagnostic study of anorectal malformation has by the authors been considered a work of classification, but of identification. Among the diagnostic procedures in use in author's Institute, preoperative CT of pelvis is performed to assess the presence and to define the development of muscular sphincteric structure towards prognostic evaluation of continence, the major long-term goal. Seven patients, aged 1-30 months, with anorectal anomalies were studied with preoperative CT of the pelvis. CT scans showed well-developed sphinteric muscles in 3 patients (2 with recto-ureteral and 1 with recto-vestibular fistulas), poorly-developed muscular structure in 3 patients (with recto-vaginal, cloacal and prostatic fistulas), absence of muscular structure in 1 ...

1989-01-01

296

Need for New Optimisation Strategies in CR and Direct Digital Radiography  

Energy Technology Data Exchange (ETDEWEB)

Digital imaging techniques such as Digital Image Intensifier Radiography and Digital Storage Phosphor (Selenium) Radiography are replacing conventional film-screen radiography more and more. The aim of this development is the extension of diagnostic capabilities and the reduction of side effects such as radiation dose. Conventional film-screen radiography and digital radiography are very different ways of imaging. For digital radiography specific post-processing is the link between imaging conditions and film documentation. Optimisation of the images includes new possibilities of post-processing and a broad range for variation of the dose. Especially in fluoroscopy, dose can be reduced significantly by new technical features like pulsed fluoroscopy. For digital radiography the European guidelines on quality criteria have to be applied to projection radiography, digital subtraction radiography and to fluoroscopy. Further work should lead to a definition of reference ...

2000-07-01

297

Need for New Optimisation Strategies in CR and Direct Digital Radiography  

International Nuclear Information System (INIS)

Digital imaging techniques such as Digital Image Intensifier Radiography and Digital Storage Phosphor (Selenium) Radiography are replacing conventional film-screen radiography more and more. The aim of this development is the extension of diagnostic capabilities and the reduction of side effects such as radiation dose. Conventional film-screen radiography and digital radiography are very different ways of imaging. For digital radiography specific post-processing is the link between imaging conditions and film documentation. Optimisation of the images includes new possibilities of post-processing and a broad range for variation of the dose. Especially in fluoroscopy, dose can be reduced significantly by new technical features like pulsed fluoroscopy. For digital radiography the European guidelines on quality criteria have to be applied to projection radiography, digital subtraction radiography and to fluoroscopy. Further work should lead to a definition of reference ...

1999-06-13

298

MRI of congenital heart disease in childhood  

International Nuclear Information System (INIS)

MRI provides a non-invasive diagnostic tool complementing echocardiography on one hand, and showing advantages over echocardiography, on the other hand, especially after corrective procedures. The multiple different MRI sequences need to be adapted to examinations of children and patients with congenital heart disease (CHD), and can be used to detect morphologic changes, blood-flow in the heart and thoracic vessels and diastolic or systolic function of myocardium. Several factors determine the success of the examination of a complex congenital heart disease or a postoperative situs. Pediatric radiologists and radiologists experienced in congenital heart diseases have to work in close cooperation. Echocardiography should be performed before MRI. The results of prior examinations and the clinical history of the patients, including possible palliative or reconstructive operations, must be available before MRI to guide the planning of the examination. With a systematic ...

2004-02-01

299

MR imaging and MR cholangiopancreatography in the preoperative evaluation of hilar cholangiocarcinoma: correlation with surgical and pathologic findings  

International Nuclear Information System (INIS)

The primary aim was to evaluate delayed contrast-enhanced MRI in depicting perineural spread of hilar cholangiocarcinoma (CCC) and consequently to determine the capability of MRI/MRCP for staging CCC. Fifteen patients that underwent MRI/MRCP and surgical treatment were retrospectively included. Two radiologists evaluated MR images to assess delayed periductal enhancement, extent of bile duct stenosis, liver parenchymal and vascular involvement and presence of liver atrophy. An agreement between delayed enhancement of the bile duct walls and perineural neoplastic spread showed a very good correlation factor (0.93). The overall accuracy in detecting biliary neoplastic invasion was higher for delayed T1-weighted images (93.3%) than for the MRCP images (80%), and T1-delayed image increased the MR accuracy in assessing the neoplastic resectability (p < 0.05). MRI correctly predicted vascular involvement in 73% and liver involvement in 80% of the cases. The number of overall correctly ...

2008-10-01

300

Locally Optimally-emitting Clouds and the Narrow Emission Lines in Seyfert Galaxies  

CERN Document Server

The narrow emission line spectra of active galactic nuclei are not accurately described by simple photoionization models of single clouds. Recent Hubble Space Telescope images of Seyfert 2 galaxies show that these objects are rich with ionization cones, knots, filaments, and strands of ionized gas. Here we extend to the narrow line region the ``locally optimally emitting cloud'' (LOC) model, in which the observed spectra are predominantly determined by powerful selection effects. We present a large grid of photoionization models covering a wide range of physical conditions and show the optimal conditions for producing many of the strongest emission lines. We show that the integrated narrow line spectrum can be predicted by an integration of an ensemble of clouds, and we present these results in the form of diagnostic line ratio diagrams making comparisons with observations. We also predict key diagnostic line ratios as a function of distance ...

1997-01-01

301

Handbook on diagnostic radiology. Muscels and skeleton 2; Handbuch diagnostische Radiologie. Muskuloskelettales System 2  

Energy Technology Data Exchange (ETDEWEB)

The second volume contains a comprehensive presentation of inflammatory bone diseases, including seldom primary chronic osteomyelitis and morbus Paget. Substantial chapters on bone tumors and tumor-like lesions of bone joints are covering the state-of-the-art of diagnostic techniques of these seldom but important diseases. Besides the importance of projection radiography the contribution of MRI within differential diagnosis und staging of these diseases is emphasized. [German] Der zweite Band des Muskuloskelettalen Systems befasst sich mit der umfassenden Darstellung zur Diagnostik entzuendlicher Knochenerkrankungen und beinhaltet neben den klassischen infektioesen auch die seltenen, primaer chronischen Osteomyelitiden und den Morbus Paget. Umfangreiche Kapitel ueber die Knochentumoren und tumoraehnlichen Laesionen der Gelenke stellen in modernster Weise den aktuellen Stand des Wissens und der Diagnostik dieser seltenen, aber aus differenzialdiagnostischer Sicht ...

2005-07-01

302

Fast diagnosis and treatment of crack-like defect injuriousness in nuclear power plant equipment  

Energy Technology Data Exchange (ETDEWEB)

Increasingly stringent safety requirements governing the nuclear industry have made it essential to gain in-depth knowledge of the injuriousness of cracking phenomena in auxiliary and secondary nuclear power plant systems, and to devise methods of rapidly evaluating potentially injurious flaws. The Defect Injuriousness Diagnosis and Treatment Package (DIDTP) discussed in this paper was developed by Framatome, a French-based PWR builder, with this goal in mind. A general description is given of the DIDTP, which is made up of tables and nomographs illustrating the injuriousness of flaws liable to be encountered in the most severely loaded regions of plant systems. The basic principles underlying the DIDTP, together with computational methods and application procedure, are detailed. Two practical examples illustrating the use of the diagnostic system are presented, one applied to the main steam line, the other to gate valve wedges. The types of results obtained and ...

1985-01-01

303

Equation of state of laser-shocked compressed iron; Equation d'etat du fer comprime par choc laser  

Energy Technology Data Exchange (ETDEWEB)

This thesis enters the field of highly compressed materials equation of state studies. In particular, it focuses on the case of laser shock compressed iron. This work indeed aims at getting to the conditions of the earth's core, comprising a solid inner core and a liquid outer core. The understanding of phenomena governing the core's thermodynamics and the geodynamic process requires the knowledge of iron melting line locus around the solid-liquid interface at 3.3 Mbar. Several experiments were performed to that extent. First, an absolute measurement of iron Hugoniot was obtained. Following is a study of partially released states of iron into a window material: lithium fluoride (LiF). This configuration enables direct access to compressed iron optical properties such as reflectivity and self-emission. Interface velocity measurement is dominated by compressed LiF optical properties and is used as a pressure gauge. Using a dual wavelength reflectivity ...

2004-01-01

304

Eddy currents signal processing for steam generator inspection in PWR nuclear power plants; Traitement des signaux de courants de Foucault pour le controle des tubes de generateurs de vapeur dans les centrales nucleaires REP  

Energy Technology Data Exchange (ETDEWEB)

Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostics system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of these items.

1991-07-01

305

Eddy currents signal processing for steam generator inspection in PWR nuclear power plants. Traitement des signaux courants de Foucault pour le controle des tubes de generateurs de vapeur dans les centrales nucleaires REP  

Energy Technology Data Exchange (ETDEWEB)

Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostic system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of these items.

1992-01-01

306

Diagnostic possibilities following implantation of carbon-fibre-reinforced plastic (CFRP) total hip arthroplasty  

International Nuclear Information System (INIS)

Introduction: There are many problems in the radiological diagnosis of aseptic loosening in total hip arthroplasty. Computed tomography (CT) and magnetic resonance tomography (MRT) are not usable for metallic implants (stainless steel, cobalt alloy, titanium alloy). Material and Methods: From April 1993 to December 1993 15 CFRP non-cemented hip prostheses have been implanted. In a prospective clinical study plane radiographs, CT and MRT have been analysed. Results: Three stems were revised (1 femoral fracture, 1 severe thigh pain, 1 aseptic loosening). CFRP are not visible in plane radiographs. There was a complete (two-third of the cases) or nearly complete (one-third of the cases) small sclerotic interface between the prosthesis and the bone, these were apparent in CT and MRT in stable implant cases and did not have any clinical correlations. Discussion: The small sclerotic interface is quite different in comparison to so called 'Reactive lines'. In one case of aseptic loosening ...

307

Diagnostic imaging and interventional radiology of the amoebic liver abscess. Personal experience; Diagnostica per immagini e radiologia interventistica degli ascessi amebici del fegato: esperienza personale  

Energy Technology Data Exchange (ETDEWEB)

The diagnostic imaging findings in hepatic amoebiasis and the capabilities of percutaneous drainage have already been described but some debate is open on both diagnosis and treatment. It is reported the experience with the ultrasound (US) and Computed Tomography (CT) studies of the hepatic amoebic abscess and its management. [Italian] I reperti con diagnostica per immagini nell'amebiasi epatica e le possibilita' del drenaggio percutaneo sono stati gia' illustrati; esistono tuttavia controversie sul piano sia diagnostico che terapeutico. Obiettivo di questo lavoro e' quello di riportare l'esperienza personale nella diagnostica con ecografia e tomografia computerizzata (TC) e nel trattamento degli ascessi amebici del fegato.

1999-10-01

308

Diagnostic difficulties in extraosseous Ewing's sarcoma: A proposal for diagnostic criteria  

International Nuclear Information System (INIS)

Five cases diagnosed as extraosseous Ewing's sarcoma (EES) during a 15 year period, and the relevant literature, were reviewed. The diagnosis in these cases was difficult to confirm, mainly because the distinction between the osseous form of Ewing's sarcoma (OES) and either periosteal reactions or direct tumour invasion into adjacent bone by EES was often unclear. The literature suggests that other authors have also encountered difficulties. The authors believe that many cases reported as EES are likely to have been OES. This distinction has some importance, as the two conditions are usually treated in differing ways. The following criteria are proposed for the diagnosis of primary EES: (i) no evidence of bony involvement on magnetic resonance imaging; (ii) no evidence of increased uptake in bone or periosteum adjacent to the tumour on static isotope bone scan images; (iii) a small round cell tumour with no differentiating features on light microscopy, immunochemistry or electron ...

309

Computer assisted axial tomography (Emi scan) in neurologic investigation  

Science.gov (United States)

Cerebral angiography, pneumoencephalography, and radioisotope brain scan with their differing diagnostic abilities have provided the neurologist and neurosurgeon with extremely valuable diagnostic techniques. It is doubtful, however, if any of these now conventional methods had the enormous impact on the practice of neurology that computer assisted axial tomography (C.A.T.) is beginning to have. Here, for the first time, is a test which, without significant risk or discomfort, can demonstrate some normal intracranial (and intraorbital) structures, can demonstrate some normal intracranial pathology and, in many cases, can make the potentially dangerous contrast studies unnecessary. After only a few months experience with C.A.T. in a clinical setting, it has become obvious that there will have to be a reappraisal of the accepted investigative work-up of many conditions. While it is too early to have formulated strict criteria for the use of ...

1974-01-01

310

Computed tomography of the thorax: a status report  

Energy Technology Data Exchange (ETDEWEB)

Computed tomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computed tomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. Future applications of CT include the staging of mediastinal lymph nodes in ...

1981-11-01

311

Computed tomography of the thorax: a status report  

International Nuclear Information System (INIS)

Computed tomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computed tomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. Future applications of CT include the staging of mediastinal lymph nodes in ...

312

Computed tomography of the orbit  

Energy Technology Data Exchange (ETDEWEB)

In less than a decade computed tomography (CT scanning) had a profound impact on diagnostic radiology. Radiology of the orbit is no exception. As early as 1973, reports published in the radiological literature indicated that this new noninvasive imaging method was a highly effective way of demonstrating intraorbital mass lesions. As CT scanners became widely available, computed tomography became a significant adjunct to ophthalmological diagnosis. Today the main indications for CT scanning of the orbit are: (1) suspected mass lesions, most frequently presenting as exophthalmos, (2) orbital trauma, including foreign bodies, (3) some congenital anomalies, and (4) suspicion of extension into the orbit of extraorbital disease processes. Along with ultrasonography, another new noninvasive imaging technique, CT has replaced a number of more invasive and often less effective diagnostic methods, such as orbital pneumography, venography, and ...

1981-01-01

313

Computed radiography. Evaluation of its role in the mass survey for lung cancer: Phantom study  

Energy Technology Data Exchange (ETDEWEB)

In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in the retrocardiac and subdiaphragmatic regions, respectively. This may have implications for the value of simultaneous ...

1987-12-01

314

Computed radiography  

International Nuclear Information System (INIS)

In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in the retrocardiac and subdiaphragmatic regions, respectively. This may have implications for the value of simultaneous ...

1987-01-01

315

Adaptation of a cubic smoothing spline algortihm for multi-channel data stitching at the National Ignition Facility  

Energy Technology Data Exchange (ETDEWEB)

Some diagnostics at the National Ignition Facility (NIF), including the Gamma Reaction History (GRH) diagnostic, require multiple channels of data to achieve the required dynamic range. These channels need to be stitched together into a single time series, and they may have non-uniform and redundant time samples. We chose to apply the popular cubic smoothing spline technique to our stitching problem because we needed a general non-parametric method. We adapted one of the algorithms in the literature, by Hutchinson and deHoog, to our needs. The modified algorithm and the resulting code perform a cubic smoothing spline fit to multiple data channels with redundant time samples and missing data points. The data channels can have different, time-varying, zero-mean white noise characteristics. The method we employ automatically determines an optimal smoothing level by minimizing the Generalized Cross Validation (GCV) score. In order to automatically ...

2010-12-28

316

A marvel of colors and ingredients. The story of urine test strip.  

Science.gov (United States)

The history of the urinary test papers does not being in the post-war period. As early as the 1880's some practitioners and pharmacists tried to replace the complicated wet-chemical procedures and apparatus by "dry chemistry." The first popular test paper for sugar and albumin originated in England in 1883. Dry reagents for proving hematuria have been available since the beginning of this century. Until the 1930s a wide palette of commercial urine tests with "modern" brand names was established. A methodological breakthrough was created by the spot test chemistry inaugurated by the Austrian, Fritz Feigl, about 1920. Using the capillary properties of filter paper in enhancing color reactions he founded a new area of analytical chemistry. Many of the pioneers were recruited from Jewish scientists. In this lecture is proposed that their emigration and banishment as well as the Second World War have stopped the development of urinary diagnostics on the European ...

1994-11-01

317

Works on the start-up of an infrared free-electron laser in FIAN  

International Nuclear Information System (INIS)

The description and results of the study on the free-electron laser (FEL) on 100 #mu#m, representing the first line of the FIAN multipurpose radiation complex, are presented. The electron beam with the energy of 6-8 MeV, once accelerated in a racetrack microtron and extracted into the FEL injection tract, is used for exciting this FEL. The system of the electron beam transport, injection and diagnostics are described. Additional works on increasing the beam emittance up to 0.4 A for one energy spread percent are carried out. The obtained electron beam parameters assure generation of the far infrared radiation in the FEL

2000-10-17

318

Treatment of multi-ruptured complex pseudoaneurysm with injection of fibrin sealant into lumens: report of one case with literature review  

International Nuclear Information System (INIS)

This paper is to report a case of multi-ruptured complex pseudoaneurysm confirmed by three-dimensional DSA. Under three-dimensional DSA guidance, the thrombin was injected into lumens in the attempt to cure the pseudoaneurysm. As the result was unsatisfactory, fibrin sealant was used to inject into the lumens again, and good curative effect was obtained. In clinical interventional practice, the incidence of pseudoaneurysm has been steadily increasing and the lesions have become more and more complex. In this paper the authors have discussed the diagnostic and therapeutic methods of complex pseudoaneurysm in order to provide clinical physicians with useful information. (authors)

2009-03-01

319

The value of computed tomography in the diagnosis of grating scapula  

Energy Technology Data Exchange (ETDEWEB)

Snapping or grating scapula is a condition of the shoulder girdle in which the patient complains of pain and an audible snapping sound which may be associated with pain. We evaluated the diagnostic value of the computed tomography (CT) scans using the clinical diagnosis of a grating scapula as the gold standard. This retrospective study reports the sensitivity, specificity, likelihood ratio and receiver operator characteristic curve for the CT scans and the k value as a measure of the interobserver agreement. None of the parameters validated the examination. We therefore concluded that CT scans are inappropriate for differentiation between a grating scapula and a normally functioning shoulder except in cases where bony abnormalities are present. (orig.)

1994-07-01

320

The CDMS II data acquisition system  

Energy Technology Data Exchange (ETDEWEB)

The Data Acquisition System for the CDMS II dark matter experiment was designed and built when the experiment moved to its new underground installation at the Soudan Lab. The combination of remote operation and increased data load necessitated a completely new design. Elements of the original LabView system remained as stand-alone diagnostic programs, but the main data processing moved to a VME-based system with custom electronics for signal conditioning, trigger formation and buffering. The data rate was increased 100-fold and the automated cryogenic system was linked to the data acquisition. A modular server framework with associated user interfaces was implemented in Java to allow control and monitoring of the entire experiment remotely.

2011-01-01

321

Technetium complexes as potential brain imaging agents  

International Nuclear Information System (INIS)

Single photon tomography using lipophilic tracers provides tomographic representations of regional blood flow. To penetrate a healthy blood-brain barrier requires that radiotracers either are fat-soluble or have an affinity for one of the selective blood-brain barrier transport systems. In recent years there has been an increasing interest to explore the ideal physical characteristics of "9"9"mTc for diagnostic problems of brain diseases. The development of radiopharmaceuticals for brain imaging including the intensively studied "9"9"mTc-propyleneamineoxime derivatives is discussed. (author).

322

Seismic and Rockphysics Diagnostics fo Multiscale Reservoir Textures  

Energy Technology Data Exchange (ETDEWEB)

We have continued to finish up our work on analyzing relationships between elastic properties and rock microstructure. We have worked on theoretical models for the effects of sorting and packing on elastic moduli and seismic velocities. After analyzing the scanning acoustic images of shales to quantify textures at different scales, we are now using theoretical inclusion models to quantify the elastic property variation with texture. In the closing phases of this project most of our efforts are now focused on writing up the results and preparing the final reports.

2005-02-01

323

Role of nuclear medicine bone scans in evaluating pain in athletic injuries  

Energy Technology Data Exchange (ETDEWEB)

The utilization of nuclear medicine bone scanning examinations early in the diagnostic process allows physicians to render prompt and correct treatment in urgent or difficult athletic cases. Bone scanning should be performed for athletic injuries whenever (1) x-rays are normal but bone or joint pain persists; (2) x-rays are positive but it cannot be determined if the findings are acute or chronic; (3) soft-tissue injuries present and x-rays are not useful; and (4) bone pain or joint impairment present without a history of trauma.89 references.

1987-10-01

324

Resuscitation and monitoring in gastrointestinal bleeding  

British Library Electronic Table of Contents (United Kingdom)

Introduction Gastrointestinal bleeding is a common life-threatening problem, causing significant mortality, costs and resource allocation. Its management requires a dynamic multidisciplinary approach that directs diagnostic and therapeutic priorities appropriately. Materials and methods Articles published within the past 15 years, related to gastrointestinal bleeding, were reviewed through MEDLINE search, in addition to current guidelines and standards. Results Decisions of ICU admission and blood transfusion must be individualized based on the extent of bleeding, hemodynamic profile and comorbidities of the patient and the risk of rebleeding. A secure airway may be required to optimize oxygenation and to prevent aspiration. Doses of induction agents must be reduced due to the changes in v...

2011-01-01

325

Radiation-protection survey guide: fixed radiographic unit. Final report, June 1980-April 1985  

Energy Technology Data Exchange (ETDEWEB)

Prior to routine use, all newly installed x-ray machines must have a radiation-protection survey by a qualified expert. The survey is an evaluation of existing or potential radiation hazards associated with the use of diagnostic x-ray equipment under specific conditions. Such evaluation includes the measurement of exposure levels in the environment as well as environmental levels arising from operation of the equipment. The survey also includes an evaluation of the safety characteristics of the x-ray unit.

1985-05-01

326

Preliminary Study of Plasma Stream Interaction with Tungsten Target within RPI-IBIS Facility  

International Nuclear Information System (INIS)

The paper presents results of experimental research on the interaction of a pulsed plasma-ion stream with a tungsten (W) target. The pulsed hydrogen plasma was produced within the RPI-IBIS (Multi-Rod Plasma Injector) facility at IPJ in Swierk. Measurements were carried out by means of optical spectroscopy and corpuscular diagnostic techniques. For experiments with the W-target the operational conditions (so-called PID mode) were chosen when a clean hydrogen plasma stream was generated. Attention was paid to the identification of WI and WII spectral lines.

2006-01-01

327

Plasma-edge studies in ISX-B and EBT-S using surface probes and laser-induced fluorescence  

Energy Technology Data Exchange (ETDEWEB)

Surface probe and laser-induced fluorescence measurements in ISX-B and EBT-S have made significant contributions to the understanding of plasma edge characteristics and plasma-surface interactions in these devices. Where comparison is possible, these techniques have led to results which are consistent with plasma diagnostics. Charge-exchange neutral sputtering and self-ion sputtering have been identified as the dominent heavy impurity release mechanisms in ISX-B and EBT-S, respectively.

1982-08-01

328

Picosecond timing of terawatt laser pulses with the SLAC 46 GeV electron beam  

International Nuclear Information System (INIS)

We report on the collision of 1.5 ps (FWHM) laser pulses traversing at 17 a short similar 7 ps (FWHM) 46.6 GeV electron bunch. The phase-locked system used to maintain the correct timing of the laser pulses and the appropriate diagnostics are described. The jitter between the laser and electron pulses is determined from the stability of the observed rate of Compton scatters and can be described by a Gaussian distribution with #sigma#_j#approx =#2.2 ps. (orig.).

329

Organ doses and integral doses in X-ray diagnosis of the chest and of the head  

International Nuclear Information System (INIS)

Organ and tissue doses and integral doses in patients due to diagnostic x-ray examinations of the chest and of the head will be presented. These data have been obtained by measuring the dose distributions in man phantoms by LiF-dosimetry. The data will be compared with data obtained by Monte-Carlo calculations. To obtain average organ doses for a special type of examination for the population or for a specified subpopulation in the variation of the exposure, data due to the different techniques used by the different radiologists has to be known. Such data will be presented. The results of the investigation will be discussed in connection with the concept of the 'somatic significant.

1977-04-01

330

On the development of a laser detonator  

Science.gov (United States)

The initiation of explosives by laser illumination has been known for many years. In this paper we will discuss the development of a working detonator design that reduces the energy required for detonation in a low-density secondary explosive by vaporizing a thin metal coating. We present data on the development of the design for a workhorse laser detonator that provides enhanced safety over existing exploding bridgewire detonators (EBWs). Comparison of this laser initiated data to an exploding-bridgewire (EBW) provides insight into the mechanism of initiation of detonation in low-density PETN by the plasma source. A novel diagnostic technique to determine the run-distance to detonation also known as the apparent Center-of-Initiation (COI) will also be discussed.

2005-09-01

331

New treatments for agitation.  

Science.gov (United States)

Acute agitation is a frequent reason for emergency psychiatric intervention. It is important to intervene early to avoid escalation of agitation to aggression. Reducing risk by using effective treatments will result in fewer instances of seclusion and restraint, and fewer injuries to staff and patients. This paper will first review the epidemiology of aggressive behavior and mental disorders, followed by a discussion of assessment and diagnostic considerations. The pathophysiology of safety risk is discussed within the context of the model of the "triune brain." Pharmacological treatment strategies for acute episodes of agitated behavior will be discussed in detail. This includes newer formulations of novel antipsychotics such as liquids and rapidly disintegrating tablets, as well as intramuscular preparations. PMID:15335224

2004-01-01

332

MRI survival guide  

International Nuclear Information System (INIS)

The book is a German translation of an American textbook with the original title ''MRI Survival Guide'' and is intended to serve as an introductory guide for beginners or a reference book for quick information. Readers will find information on the fundamentals of the technology and methodology of MRI as well as all details of relevance to practice in a precise and easy-to-grasp arrangement, covering all anatomic areas of interest, illustrations and descriptions of characteristic signs of pathologic processes, high-quality and unusually large-sized diagnostic pictures, a modern didactic concept for quick orientation, including surveys, tables, and reproductions for visualisation of contents. (orig./CB)

333

Locked nucleic acid (LNA): High affinity targeting of RNA for diagnostics and therapeutics  

DEFF Research Database (Denmark)

Locked nucleic acid (LNA) is a nucleic acid analogue containing one or more LNA nucleotide monomers with a bicyclic furanose unit locked in an RNA mimicking sugar conformation. This conformational restriction results in unprecedented hybridization affinity towards complementary single stranded RNA and thus, makes LNA uniquely suited for mimicking RNA structures and sequence specific targeting of RNA in vitro or in vivo. The focus of this paper is on LNAantisense, LNA-modified siRNA (siLNA), and detection and analysis of microRNAs by LNA-modified oligonucleotide probes.

2005-01-01

334

Linac Coherent Light Source (LCLS) Bunch-Length Monitor using Coherent Radiation  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) is a SASE x-ray Free-Electron Laser (FEL) based on the final kilometer of the Stanford Linear Accelerator. One of the most critical diagnostic devices is the bunch length monitor (BLM), which is to be installed right after each compressor utilizing coherent radiation from the last bending magnet. We describe the components and the optical layout of such a BLM. Based on the setup geometry, we discuss some issues about the coherent radiation signal.

2007-03-21

335

Light elements in massive single and binary stars  

CERN Document Server

We highlight the role of the light elements (Li, Be, B) in the evolution of massive single and binary stars, which is largely restricted to a diagnostic value, and foremost so for the element boron. However, we show that the boron surface abundance in massive early type stars contains key information about their foregoing evolution which is not obtainable otherwise. In particular, it allows to constrain internal mixing processes and potential previous mass transfer event for binary stars (even if the companion has disappeared). It may also help solving the mystery of the slowly rotating nitrogen-rich massive main sequence stars.

2010-01-01

336

Labeled cells as research, diagnostic and therapeutic tools  

Energy Technology Data Exchange (ETDEWEB)

Scientists at JPL have developed chemical and biological techniques using microspheres filled with drugs, electron-opaque metals, or radioactive, fluorescent, magnetic or electrically charged materials to label specific groups of cells. Synthetic polymeric microspheres are coupled with specific antibodies to form reagents called immunomicrospheres, which can seek out and attach themselves to any specific group of cells. These cell-labeling techniques, therefore, open new avenues not only to the basic study of cells but also to the diagnosis and treatment of many diseases, including cancer.

1983-09-01

337

LCLS XTOD Tunnel Vacuum System (XVTS)  

Energy Technology Data Exchange (ETDEWEB)

The vacuum system of the XVTS (X-Ray Vacuum Transport System) for the LCLS (Linac Coherent Light Source) XTOD (X-ray Transport, Optics and Diagnostics) system has been analyzed and configured by the Lawrence Livermore National Laboratory's NTED (New Technologies Engineering Division) as requested by the SLAC/LCLS program. The system layout, detailed analyses and selection of the vacuum components for the XTOD tunnel section are presented in this preliminary design report. The vacuum system was analyzed and optimized using a coupled gas load balance model of sub-volumes of the components to be evacuated. Also included are the plans for procurement, mechanical integration, and the cost estimates.

2005-11-04

338

Interview: Trevor Keel from the World Gold Council  

British Library Electronic Table of Contents (United Kingdom)

Trevor Keel speaks to Cara Sutton, Assistant Commissioning Editor Within the World Gold Council's technology sector, Trevor Keel is responsible for a range of activities in relation to the development of new gold-based technologies. He has particular interest in the use of gold in the fields of medicine and diagnostics, catalysis and nanotechnology. Previously, Trevor was a principal chemist at GlaxoSmithKline where he was involved in numerous New Chemical Entity projects. Dr Keel has an extensive knowledge of nanotechnology, having completed a PhD in Pharmaceutical Nanotechnology at the University of Nottingham, Nottingham, UK.

2011-01-01

339

International trends in radiation protection  

International Nuclear Information System (INIS)

The great uranium debate throughout the industrialised world has intensified awareness of the biological hazards from ionizing radiation. It is therefore appropriate to use this awareness to draw attention to medical X-Radiation which today represents the most significant risk to future generations. There is ample legislation to control proliferation of nuclear development but in diagnostic radiology proliferation is unlimited; most international surveys indicate an unchecked annual growth rate of 15%. The article looks at risk hypotheses, dose measurements and the responsibilities of practising radiographers, and also reviews the international situation as reported at the 1977 world congress of radiation protection.

340

Initial electron-beam characterizations for the Los Alamos APEX Facility  

Energy Technology Data Exchange (ETDEWEB)

The ongoing upgrade of the Los Alamos Free-Electron Laser (FEL) Facility involves the addition of a photoelectric injector (PEI) and acceleration capability to about 40 MeV. The electron-beam and high-speed diagnostics provide key measurements of charge, beam position and profile, divergence emittance, energy (centroid, spread, slew, and extraction efficiency), micropulse duration, and phase stability. Preliminary results on the facility include optical transition radiation interferometer measurements of divergence (1 to 2 mrad), FEL extraction efficiency (0.6 {plus minus} 0.2%), and drive laser phase stability (< 2 ps (rms)). 10 refs.

1991-01-01

341

Initial electron-beam characterizations for the Los Alamos APEX Facility  

Energy Technology Data Exchange (ETDEWEB)

The ongoing upgrade of the Los Alamos Free-Electron Laser (FEL) Facility involves the addition of a photoelectric injector (PEI) and acceleration capability to about 40 MeV. The electron-beam and high-speed diagnostics provide key measurements of charge, beam position and profile, divergence emittance, energy (centroid, spread, slew, and extraction efficiency), micropulse duration, and phase stability. Preliminary results on the facility include optical transition radiation interferometer measurements of divergence (1 to 2 mrad), FEL extraction efficiency (0.6 {plus_minus} 0.2%), and drive laser phase stability (< 2 ps [rms]). 10 refs.

1991-12-31

342

Idiopathic renal hematuria in a military working dog.  

Science.gov (United States)

A 1.5-year-old male Belgian Malinosis Military Working Dog presented with a 1-month history of intermittent hematuria. Diagnostic ultrasound and contrast radiography demonstrated large blood clots in the urinary bladder and a filling defect in the right renal pelvis. At surgery, clotted blood was present in the right ureter and bladder. Following right nephrectomy, the dog returned to training. One month later, elevations in urea nitrogen and creatinine were noted. Hematuria recurred at 3 months and the dog was found dead in its kennel. Necropsy showed a blood-filled left renal pelvis and ureter. PMID:1454185

1992-10-01

343

Gross anatomy of network security  

Science.gov (United States)

Information security involves many branches of effort, including information assurance, host level security, physical security, and network security. Computer network security methods and implementations are given a top-down description to permit a medically focused audience to anchor this information to their daily practice. The depth of detail of network functionality and security measures, like that of the study of human anatomy, can be highly involved. Presented at the level of major gross anatomical systems, this paper will focus on network backbone implementation and perimeter defenses, then diagnostic tools, and finally the user practices (the human element). Physical security measures, though significant, have been defined as beyond the scope of this presentation.

2002-01-01

344

Gastrointestinal radiography using Fuji computed radiography (FCR)  

International Nuclear Information System (INIS)

Initial clinical experience in gastrointestinal radiography using Fuji Computed Radiography(FCR) system was reported. Image quality of conventional film/screen radiography and FCR system on upper GI series and barium enema was compared. Reflecting wide dynamic range of the system, improved image quality was confirmed, particularity in visibility of fine mucosal pattern(area gastricae), folds and overall contour. High sensor sensitivity of the system could reduce radiation dose requirement significantly. Diagnostically acceptable images were obtained with approximately 1/5 of routine dose for conventional radiography except in cases of lateral view of the rectum. (author).

1985-01-01

345

Gaseous dielectrics V  

Energy Technology Data Exchange (ETDEWEB)

This book discusses the progress and problems of current interest in gaseous dielectrics and their use, with special emphasis on insulation in high-voltage transmission lines and substations. Topics covered include: basic physics of gaseous dielectrics; basic mechanisms; gas decomposition, reactions and toxicity; diagnostics and field probes; gases and mixtures for GIS transformers and circuit breakers; gaseous media for discharge chemistry and etching/corona; gas engineering for pulsed power and switching; gas breakdown under steep-fronted voltages; new developments in gas-insulated equipment and gas handling; gas/insulator interface/flashover; and quality control in testing gas-insulated equipment. Contains approximately 85 papers.

1987-01-01

346

First experiences with application of gadolinium-DTPA in infants and small children under two years of age  

International Nuclear Information System (INIS)

The use of Gadolinium-DTPA as a paramagnetic contrast agent in MRI with adults and juveniles concerning brain and spinal cord pathology is well proven since years. In the FRG it is only introduced for children over two years of age. Therefore this report deales with the experience in four infants and small children under the age of two. They all were suffering from neurological tumors and got additional diagnostic information in three cases. Clinical side-effects like urticaria, vomiting or convulsions had not been observed nor had pathologic changes of the biochemical parameters been noticed. (orig./GDG).

347

Fabrication of the 320-CM-OD all-ceramic ZT-40 torus  

International Nuclear Information System (INIS)

The fabrication of the ZT-40 torus, a large complex all-ceramic toroidal plasma containment vessel, is described. Several glass sealants covering the temperature range of 500 to 1300"0C, were developed and used to ''braze'' segments of the torus together, sapphire windows to the torus and the required pump-out and diagnostic parts to the ceramic vacuum vessel. Designs of window seals were developed that allowed sealing of the sapphire windows in a vertical position with minimum sealing glass flow.

348

Extraction methods of multi-fault information in machine condition monitoring  

Energy Technology Data Exchange (ETDEWEB)

An outline of the multi-fault diagnostic observation concept is presented in the paper. Starting from the commonly used singular value decomposition (SVD) it is shown, that it is equivalent to the modern version of principal component analysis (PCA). During the development of the concept of multi-fault observation several indices and measures obtained from SVD were tried, and some seem to bring the success. This problem is also addressed in the paper and illustrated by real examples taken from railroad Diesel engine condition monitoring. (orig.)

2003-07-01

349

Experiments to investigate the effects of radiative cooling on plasma jet collimation  

CERN Document Server

Preliminary experiments have been performed to investigate the effects of radiative cooling on plasma jets. Thin (3 um - 5 um) conical shells were irradiated with an intense laser, driving jets with velocities > 100 km/s. Through use of different target materials - aluminium, copper and gold - the degree of radiative losses was altered, and their importance for jet collimation investigated. A number of temporally resoved optical diagnostics was used, providing information about the jet evolution. Gold jets were seen to be narrower than those from copper targets, while aluminium targets produced the least collimated flows.

2010-01-01

350

Development of thin foil Faraday collector as a lost alpha particle diagnostic for high yield D-T tokamak fusion plasmas  

Energy Technology Data Exchange (ETDEWEB)

Alpha particle confinement is necessary for ignition of a D-T tokamak fusion plasma and for first wall protection. Due to high radiation backgrounds and temperatures, scintillators and semiconductor detectors may not be used to study alpha particles which are lost to the first wall during the D-T programs on JET and ITER. An alternative method of charged particle spectrometry capable of operation in these harsh environments, is proposed: it consists of thin foils of electrically isolated conductors with the flux of alpha particles determined by the positive current flowing from the foils. 2 refs., 3 figs.

1994-07-01

351

Cutaneous leishmaniasis associated with jungle training.  

Science.gov (United States)

In November 1977, 627 soldiers belonging primarily to the First Battalion, 82nd Airborne Division, stationed at Fort Bragg, were sent to the Canal Zone, Panama, for jungle warfare training. A medical surveillance program incorporating pre- and post-evaluations over a 6-month period with dermatologic examinations, questionnaires, and serologic tests was established. Ten cases of cutaneous leishmaniasis (1.6/100 men) were diagnosed by positive Leishmania culture. The demonstrated lack of sensitivity and specificity of the indirect fluorescent antibody test and the direct agglutination test render these serological methods useless as diagnostic screening methods in the early stages of this disease. PMID:7406101

1980-07-01

352

Cost-time management: A powerful tool in a new application - cleaning up the weapons complex  

International Nuclear Information System (INIS)

Westinghouse Electric Corporation is aggressively applying cost-time management to bolster timely, cost-effective cleanup and waste management activities at sites it manages for the U.S. Department of Energy (DOE). Cost-time management is a diagnostic technique which is applicable to virtually any process. It identifies opportunities to reduce cycle-times and costs. When applied to cleanup and waste management at DOE facilities, cost-time profile analysis helps identify actions to improve productivity and quality. Moreover, by reducing cycle-times and costs, it achieves significant savings to taxpayers. (author)

1992-03-01

353

Convoluted cells as a marker for maternal cell contamination in CVS cultures  

DEFF Research Database (Denmark)

In order to identify cells of maternal origin in CVS cultures, tissue from 1st trimester abortions were cultivated and the cultures stained in situ for X-chromatin. Convoluted cells and maternal fibroblasts were found to be positive. By chromosome analysis of cultures from 105 diagnostic placenta biopsies, obtained by the transabdominal route, metaphases of maternal origin were found in nine cases. In eight of these cases colonies of convoluted cells were observed. We conclude that convoluted cells are of maternal origin and are a reliable marker for maternal cell contamination in CVS cultures.

1987-01-01

354

Confocal Imaging of Biological Tissues Using Second Harmonic Generation  

Energy Technology Data Exchange (ETDEWEB)

A confocal microscopy imaging system was devised to selectively detect Second harmonic signals generated by biological tissues. Several types of biological tissues were examined using this imaging system, including human teeth, bovine blood vessels, and chicken skin. All these tissues generated strong second harmonic signals. There is considerable evidence that the source of these signals in tissue is collagen. Collagen, the predominant component of most tissues, is known to have second order nonlinear susceptibility. This technique may have diagnostic usefulness in pathophysiological conditions characterized by changes in collagen structure including malignant transformation of nevi, progression of diabetic complications, and abnormalities in wound healing.

2000-03-06

355

Computed tomography in the evaluation of soft tissue tumors  

International Nuclear Information System (INIS)

In order to evaluate the role of Computed Tomography (CT) in prediction of nature, staging and follow-up of soft-tessue tumors, the authors examined by CT 124 patients with soft tissue neoplasms who later underwent surgery (116 cases) or fine needle biopsy (8 cases). Comparison between CT and surgical or anatomical results showed that CT was able to correctly predict the benignancy or malignancy of the masses in 76% of cases but it was very seldom able to allow an hystological prediction. On the contrary CT was found to be a very useful tool for pre-therapeutic staging and follow-up of the tumors, because it gave many diagnostic information which influenced therapeutic choiches and strategies.

1986-01-01

356

Computed tomography in spinal osteoblastoma  

International Nuclear Information System (INIS)

In order to stress the role of computed tomography (CT) in the evaluation of benign spinal osteoblastoma, the authors examined by CT 10 patients with surgically and histologically proved osteoblastomas of the spine. Basing on surgical and histopathological findings CT proved to be a very important method for attesting the presence of the tumors (usually showed by radiographic examination), and specially for their staging and follow-up. CT in fact showed the real extent of the tumor into the spinal canal and towards the paraspinal soft tissues, and allowed the aerly detection of post surgical relapses. The authors conclude that CT is a primary diagnostic modality for preoperative planning and follow-up of benign osteoblastoma.

1986-01-01

357

Bilateral lipoma arborescens of the bicipitoradial bursa  

International Nuclear Information System (INIS)

A 37-year-old military mechanic presented to our institution with a chronic history of a slowly enlarging left elbow antecubital fossa mass. There was no history of other chronic illness or trauma. Magnetic resonance imaging (MRI) and excisional biopsy revealed fatty villi and synovial inflammation within the left bicipitoradial bursa, consistent with lipoma arborescens. Four years later the patient presented with a 6-month history of swelling at the antecubital fossa of the opposite elbow. Diagnostic computed tomography and MRI examinations were performed. The surgical and pathologic findings confirmed the imaging diagnosis of lipoma arborescens at the right bicipitoradial bursa. (orig.)

2002-11-01

358

Analysis of brain CT on 120 patients of human cysticercosis  

International Nuclear Information System (INIS)

A study on brain CT was made in 120 patients of human cysticercosis, which is a rare disease in Japan and clinical symptoms and laboratory data for the diagnosis were also discussed. From the point of therapeutic view, we proposed a new differentiation on brain CT of human cysticercosis, which is divided into two groups according to the alve or dead parasite. Furthermore, we proposed a new type named multiple large and small cysts type on brain CT. The idea of diagnostic standard was made integrating brain CT image, clinical symptoms and labolatory data. (author).

359

Aicardi syndrome: a case report and radiologic findings; Sindrome de Aicardi: relato de caso e achados radiologicos  

Energy Technology Data Exchange (ETDEWEB)

The authors report the findings of Aicardi syndrome, a disease of unknown etiology composed of multiple spasms, chorioretinal lacunae and agenesis of the corpus callosum. They present a case of Aicardi syndrome with characteristic clinical presentation and magnetic resonance imaging findings. The disease, despite being considered rare, has characteristic imaging findings. Over the past years magnetic resonance imaging has improved its ability in demonstrating other findings besides agenesis of the corpus callosum, making the radiologist's role very important in the diagnostic suspicion of this disease. (author)

2008-07-01

360

Adrenocortical (dys)function in septic shock - A sick euadrenal state  

British Library Electronic Table of Contents (United Kingdom)

A central feature of the endocrine pathophysiology of septic shock is thought to be the existence of adrenal dysfunction. Based on changes in glucocorticoid secretion and responsiveness, protein binding, and activity. These changes have been described by the terms "Relative Adrenal Insufficiency" (RAI), or "Critical Illness Related Corticosteroid Insufficiency" (CIRCI), and form part of the rationale for trials of glucocorticoid treatment in septic shock. Diagnostic criteria for these conditions have been based on plasma cortisol profiles and have proven notoriously difficult to establish. The uncertainty in this area arises from the inability of current tests to clearly identify who is truly glucocorticoid "deficient" at a cellular level, and hence who requires supplemental glucocorticoid...

2011-01-01

361

Addition of methyl cellulose enema to double-contrast barium imaging of sigmoid diverticulosis  

Energy Technology Data Exchange (ETDEWEB)

Double-contrast barium enema has a reduced sensitivity in patients with severe sigmoid diverticulosis. Therefore a carboxy methyl cellulose enema was employed after the conventional double-contrast examination in 15 patients with sigmoid diverticulosis. A significant increase in lumen diameter and a superior removal of barium residue from the diverticulas facilitated the interpretation of the sigmoid loops. Conclusion: The addition of methyl cellulose enema to double-contrast barium imaging improves diagnostic imaging in diverticulosis by expanding the lumen and emptying the diverticulas. (orig.).

1997-01-01

362

A study on diagnostic techniques of pump operating condition  

Energy Technology Data Exchange (ETDEWEB)

The scope and contents investigate and reviewed are as follows : establishment of study plan and references survey, review of related problems and inservice test standards of safety injection pump in use nuclear power plant, review of the study results in laboratory, the theoretical investigation of temperature rise according to mini-flow rate of pump, mini-flow rate working characteristics of high and low pressure injection pumps at nuclear power plants, setup of testing equipment for measuring ampere, discharge pressure and vibration, selection and behaviors analysis of major parameters concerning pump degradation.

1998-03-15

363

A neuro-fuzzy technique for fault diagnosis and its application to rotating machinery  

Energy Technology Data Exchange (ETDEWEB)

Malfunctions in machinery are often sources of reduced productivity and increased maintenance costs in various industrial applications. For this reason, machine condition monitoring is being pursued to recognise incipient faults. In this paper, the fault diagnostic problem is tackled within a neuro-fuzzy approach to pattern classification. Besides the primary purpose of a high rate of correct classification, the proposed neuro-fuzzy approach also aims at obtaining an easily interpretable classification model. The efficiency of the approach is verified with respect to a literature problem and then applied to a case of motor bearing fault classification.

2009-01-15

364

What, why, and when we image: considerations for diagnostic imaging and clinical research in the Children's Oncology Group  

Energy Technology Data Exchange (ETDEWEB)

Success in improving treatment outcomes in childhood cancer has been achieved almost exclusively through multicenter and multidisciplinary clinical and applied research over several decades. While biologically rational as well as empirical approaches have led to combination chemotherapy and multimodality approaches to therapy, which have given rise to evidence-based practice standards, similar scientific rigor has not always been as evidently applied to modalities utilized to assess initial disease burden and, more important, response to investigational approaches to therapy. As the empirical approach to therapeutic advances has likely maximized its benefit, future progress will require translation of biologic discovery most notably from the areas of genomics and proteomics. Hence, attempts to improve efficacy of therapy will require a parallel effort to minimize collateral damage of future therapeutic approaches, and such a parallel approach will mandate the continued dependence on ...

2009-02-15

365

Single-pass high-gain free electron laser electron beam diagnostics  

International Nuclear Information System (INIS)

Consensus reached in the last few years that fourth generation light source will most likely be a X-ray or a UV coherent source based on single-pass high-gain free electron laser (FEL), such as Self Amplified Spontaneous Emission (SASE), or seeded high-gain harmonic-generation (HGHG) free electron lasers. High-gain (>10"7) required for single-pass FEL puts great constrain on the quality of electron beam, and demands detailed distribution information of electron beam in six-dimension. The typical accelerator system for single-pass FEL consists of a photocathode RF gun injection system, a linac and magnetic bunch compressors, and a long undulator. The major challenges in beam diagnostics for single-pass FEL are to characterize the pico-seconds high-brightness electron beam in six-dimension produced by photocathode RF gun injector, and improve the stability and reliability of the photocathode RF gun injection system. Characterization of short electron bunch ...

2000-11-27

366

Pulmonary nodule detection of chest phantom with CRT images; Comparison with conventional radiography (film-screen system) and FCR hardcopy  

Energy Technology Data Exchange (ETDEWEB)

Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and displayed four images as a subsidiary diagnosis. The upper two ...

1989-08-01

367

Pulmonary nodule detection of chest phantom with CRT images  

International Nuclear Information System (INIS)

Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and displayed four images as a subsidiary diagnosis. The upper two ...

1989-01-01

368

New MR techniques in diagnostic imaging of joints; Neue MRT-Techniken in der Gelenkdiagnostik  

Energy Technology Data Exchange (ETDEWEB)

Already, MR Imaging is superior in diagnostic imaging of joints in many cases; however, there have been recent developments, which are the subjects of this paper. With gradient-echo sequences acquired in 3D technique, it is possible to produce high-resolution images of joints in acceptable scantime, because gradient-echo sequences are less time-consuming than convential SE sequences. With the acquisition of two echoes, phase difference between water and fat protons have to be considered. 3D Imaging is capable of displaying complex pathology in a superior way, which should be useful in preoperative planning. Tissue contrast is altered by fat saturation or magnetization transfer in order to achieve better conspicuity of lesions. Although diagnostic value of some of these options is not yet clear and further clinical studies are needed, they are a promising possibility for improving MR Imaging of the joints. (orig.) [Deutsch] In der ...

1993-12-31

369

Lung dose calculations at kilovoltage x-ray energies using a model-based treatment planning system  

International Nuclear Information System (INIS)

The determination of the dose to organs from diagnostic x rays has become important because of reports of radiation injury to patients from fluoroscopically guided interventional procedures. We have modified a convolution/superposition-based treatment planning system to compute the dose distribution for kilovoltage beams. We computed lung doses using this system and compared them to those calculated using the CDI3 organ dose calculation program. We also computed average lung doses from a simulated radiofrequency ablation procedure and compared our results to published doses for a similar procedure. Doses calculated using this system were an average of 20% lower for AP beams and 7% higher for PA beams than those obtained using CDI3. The ratio of the average dose to the lungs to the skin dose from the simulated ablation procedure ranged from 25% higher to 15% lower than that determined by other authors. Our results show that a treatment planning system designed for ...

2001-02-01

370

Image-guided pleural biopsy: diagnostic yield and complications  

International Nuclear Information System (INIS)

Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following ...

2006-08-01

371

General fundamentals of radiological diagnostics. Specific diagnostic radiology: Throat, mediastinum, diaphragm, mammary gland, infant thorax. 7. rev. ed.  

International Nuclear Information System (INIS)

The fundamentals and the technical application methods of the imaging procedures are discussed in detail with regard to their application in medicine. The development of the X-ray contrast media has led to a better tolerance and a significant reduction of risks. Problems relating to radiation protection and radiation exposure are discussed critically. The general point gives an overview of the radiological examination methods and is meant to deepen the understanding of the special techniques and their rationally determined application. The following special part deals with diagnosing of organs in the region of the neck and the thorax. The general basis is the conventional radiological examination. The great increase in information achieved by means of the new imaging methods becomes clear if we look at the diagnostics of the soft tissue of the neck. Computerized tomography and NMR imaging open the view at the fine structures of the mediastinum. Mammography is an ...

372

Electron density and collision frequency of microwave resonant cavity produced discharges. [Progress report  

Energy Technology Data Exchange (ETDEWEB)

This progress report consists of an article, the abstract of which follows, and apparently the references and vita from a proposal. A review of perturbation diagnostics applied to microwave resonant cavity discharges is presented. The classical microwave perturbation technique examines the shift in the resonant frequency and cavity quality factor of the resonant cavity caused by low electron density discharges. However, modifications presented here allow the analysis to be applied to discharges with electron densities beyond the limit predicted by perturbation theory. An {open_quote}exact{close_quote} perturbation analysis is presented which models the discharge as a separate dielectric, thereby removing the restrictions on electron density imposed by the classical technique. The {open_quote}exact{close_quote} method also uses measurements of the shifts in the resonant conditions of the cavity. Thirdly, an electromagnetic analysis is presented which uses a ...

1992-12-31

373

Diagnostic and therapeutic evaluation of "1"1"1In-vinorelbine-liposomes in a human colorectal carcinoma HT-29/luc-bearing animal model  

International Nuclear Information System (INIS)

Colorectal carcinoma is a highly prevalent and common cause of cancer in Taiwan. There is still no available cure for this malignant disease. To address this issue, we applied the multimodality of molecular imaging to explore the efficacy of diagnostic and therapeutic nanoradiopharmaceuticals in an animal model of human colorectal adenocarcinoma [colorectal cancer (CRC)] that stably expresses luciferase (luc) as a reporter. In this study, an in vivo therapeutic efficacy evaluation of dual-nanoliposome (100 nm in diameter) encaged vinorelbine (VNB) and "1"1"1In-oxine on HT-29/luc mouse xenografts was carried out. HT-29/luc tumor cells were transplanted subcutaneously into male SCID mice. Multimodality of molecular imaging approaches including bioluminescence imaging (BLI), gamma scintigraphy, whole-body autoradiography (WBAR) and in vivo tumor growth tracing, histopathology and biochemistry/hematology analyses were applied on xenografted SCID mice to study the ...

2008-07-01

374

Computerized Tomography-guided fine-needle biopsy of peripheral pulmonary nodules < 2 cm in diameter  

International Nuclear Information System (INIS)

The authors investigated the role of Computerized Tomography in guiding fine needle biopsy (FNB) in small (2 2 cm in diameter for CT-guided FNB sensitivity, specificity and diagnostic accuracy. Cytologic specimens were positive for malignancy in 40/52 cases (76.9%) and negative in 12 (23.1%). Clinical-surgical follow-up confirmed all the positive cytologic findings (40 cases), while 2 of the extant 12 cases were false negatives (95.20% sensitivity, 100% specificity and 96.15% diagnostic accuracy). 158 of 195 nodules > 2 cm in diameter and with clinical surgical follow-up (81.3%) were positive for malignancy and 34 were negative (17.43%) (98.75% sensitivity, 97.14% specificity and 98.46% diagnostic accuracy). Pneumothorax occurred in 33 patients (16.5%) with nodules > 2 cm in diameter as a complication of biopsy. Hemoptysis occurred in 15 patients (7.5%). In the whole group of lung lesions, the complications were ...

375

Clinical application of dual energy subtraction in direct digital radiography of chest  

International Nuclear Information System (INIS)

Objective: To discuss the clinical application value of dual energy subtraction (DES) in direct digital radiography of chest. Methods: 83 cases of chest digital radiography(DR) using double-energy subtraction (DES) were randomly selected, and three posterior-anterior (PA) chest films (standard image, bone image and soft tissue image) were obtained in each case, which is so called 'bone and soft tissue separated' technology. Results: With the aid of double energy subtraction (DES), the bony chest was subtracted, the sensitivity and specificity of pulmonary calcification were improved, and sensitivity of pulmonary nodes was also improved, enhancing the distinction between pulmonary benign or malignant lesions, enlightening the diagnosis of chest cage lesions, and showing a clear superiority in the detection of pulmonary nodes comparing to common chest films. The double energy subtraction (DES) films showed a higher diagnostic accuracy in the detection of bony cage ...

2009-02-01

376

Clinical MR mammography. Impact of hormonal status on background enhancement and diagnostic accuracy  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Hormonal stimulation can induce background enhancement (BE) in MR mammography (MRM). This fact has been assumed to decrease the accuracy of MRM. Consequently, this report investigates: 1. The prevalence of BE in postmenopausal vs. premenopausal women in correlation to hormonal cycle phase (CP). 2. The impact of hormonal status (HS) and BE on diagnostic accuracy. Materials and Methods: Consecutive patients over 22 months with complete HS information (week of CP or postmenopausal) were included in this prospective investigation. Exclusion criteria were any hormonal therapy, hysterectomy as well as cancer proven by biopsy. The standard of reference was histopathology. All MRM scans were acquired using the same protocol (1.5 T, dynamic T 1w GRE after 0.1 mmol/kg bw Gd-DTPA i. v.). Two radiologists rated all examinations in consensus according to BI-RADS. BE was defined as: 0 = missing, 1 = moderate, 2 = distinct. Results: 224 patients (150 postmenopausal, 74 ...

2011-05-15

377

An evaluation of current methods of diagnosing colorectal cancer in the United Kingdom  

Energy Technology Data Exchange (ETDEWEB)

Colorectal cancer (CRC) is a highly conversed topic, particularly since implementation of screening for CRC is imminent within the U.K. Aims: The aim of this research project was to examine the diagnostic tools currently used within the UK to detect CRC and their impact on the aetiology and epidemiology of CRC. Methodology: The complexity of the research topic lent itself towards a literature review. A systematic approach of researching was therefore adopted to analyse and critically evaluate the reliability and validity of articles. Electronic databases including AMED, Cancerlit, CINHAL, the Cochrane Library, EMBASE, MEDLINE and EBM-Reviews were utilised to provide a wide spectrum of recent and relevant articles. Other research strategies involved looking for books relating to the topics, which were kept to within 6 years of publication to maintain accuracy of information. Selected websites, such as NICE, the Department of Health, NHS websites and Cancer Research ...

2009-05-15

378

GRAIN REFINEMENT OF PERMANENT MOLD CAST COPPER BASE ALLOYS  

Energy Technology Data Exchange (ETDEWEB)

Grain refinement behavior of copper alloys cast in permanent molds was investigated. This is one of the least studied subjects in copper alloy castings. Grain refinement is not widely practiced for leaded copper alloys cast in sand molds. Aluminum bronzes and high strength yellow brasses, cast in sand and permanent molds, were usually fine grained due to the presence of more than 2% iron. Grain refinement of the most common permanent mold casting alloys, leaded yellow brass and its lead-free replacement EnviroBrass III, is not universally accepted due to the perceived problem of hard spots in finished castings and for the same reason these alloys contain very low amounts of iron. The yellow brasses and Cu-Si alloys are gaining popularity in North America due to their low lead content and amenability for permanent mold casting. These alloys are prone to hot tearing in permanent mold casting. Grain refinement is one of the solutions for reducing this problem. ...

2004-04-29

379

Digital image intensifier radiography: first experiences with the DSI (Digital Spot Imaging); Moeglichkeiten der digitalen Bildverstaerkerradiographie am Beispiel des Digital Spot Imaging (DSI)  

Energy Technology Data Exchange (ETDEWEB)

We performed a comparative study of digitally and conventionally acquired images in gastrointestinal examinations. Radiation dose and spatial resolution were determined in a water phantom. In 676 examinations with either conventional or digital imaging (system: Diagnost 76, DSI) the number of images and the duration of the fluoroscopy time were compared. 101 examinations with digital as well as conventional documentation were evaluated by using 5 criteria describing the diagnostic performance. The entrance dose of the DSI is 12% to 36% of the film/screen system and the spatial resolution of the DSI may be better than that of a film/screen system with a speed of 200. The fluoroscopy time shows no significant difference between DSI and the film/screen technique. In 2 of 4 examination modes significantly more images were produced by the DSI. With exception of the criterion of edge sharpness, DSI yields a significantly inferior assessment compared ...

1995-10-01

380

A new application of MRT of the lung using ultra-shot turbo spin echo sequences (UTSE); Ein neuer Ansatz in der Magnetresonanztomographie der Lunge mit einer ultrakurzen Turbo-Spin-Echo-Sequenz (UTSE)  

Energy Technology Data Exchange (ETDEWEB)

T{sub 2} weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T{sub E}=90 ms, T{sub R}=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good quality. Compared with CT, contrast is better with MRT, offering ...

1996-05-01

381

[Functional state of the hypothalamo-hypophyseal-gonadal system in patients with chronic alcoholic intoxication].  

Science.gov (United States)

The function of the hypothalamo-pituitary-gonadal system has been studied in 118 males with different stages of alcoholism. Comparison with the control group has shown decreased levels of interstitial cell stimulating hormone (ICSH), follicle-stimulating hormone (FSH), and testosterone, and elevated concentrations of prolactin (Prl). Differences in the parameters of hormonal activity expressed in a varying degree of a decrease in FSH, ICSH, and testosterone, and a Prl elevation are related to change in mutual regulatory influences between the gonads and hypothalamo-pituitary complex. The most informative parameters were concentrations of Prl and testosterone (considering elevation in the former and reduction in the latter hormone) and the ratio of their concentrations. Difference of these parameters in each group (corresponding to the stages of alcoholism) may be used as an additional diagnostic criterion of chronic alcohol intoxication. PMID:3434080

1987-01-01

382

Theory of edge radiation  

CERN Document Server

We formulate a complete theory of Edge Radiation based on a novel method relying on Fourier Optics techniques. Similar types of radiation like Transition Undulator Radiation are addressed in the framework of the same formalism. Special attention is payed in discussing the validity of approximations upon which the theory is built. Our study makes consistent use of both similarity techniques and comparisons with numerical results from simulation. We discuss both near and far zone. Physical understanding of many asymptotes is discussed. Based on the solution of the field equation with a tensor Green's function technique, we also discuss an analytical model to describe the presence of a vacuum chamber. In particular, explicit calculations for a circular vacuum chamber are reported. Finally, we consider the use of Edge Radiation as a tool for electron beam diagnostics. We discuss Coherent Edge Radiation, Extraction of Edge Radiation by a mirror, and other issues ...

2008-01-01

383

The combustion aerodynamics of a pulverized coal low NO{sub x} swirl burner in an industrial boiler  

Energy Technology Data Exchange (ETDEWEB)

This paper discusses the application of a Computational Fluid Dynamics (CFD) code (FLUENT) to predict temperature and velocity profiles, and particle trajectories in an industrial fired by a low NO{sub x} pulverized coal swirl burner. The predictions of the code were compared to experimental measurements of gas temperature, particle size distribution, and particle velocities. The diagnostics employed were a suction pyrometer and a Particle Counter Sizer Velocimeter Probe (PCSV-P). Good agreement was found between the temperature predictions and the measurements. In situ particle size distributions were predicted accurately using the Baum and Street model with a swelling factor of zero. The numerical modeling indicated that the Type II flow issued from the burner could be transformed into Type III flow, by eliminating swirl from the primary air stream, which provided the preferred particle trajectories and increased the combustion efficiency.

1996-12-31

384

The Linac Cooherent Light Source (LCLS) Accelerator  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) is a SASE x-ray Free-Electron Laser (FEL) based on the final kilometer of the Stanford Linear Accelerator. Such an FEL requires a high energy, high brightness electron beam to drive the FEL instability to saturation. When fed by an RF-photocathode gun, and modified to include two bunch compressor chicanes, the SLAC linac will provide such a high quality beam at 14 GeV and 1-{micro}m normalized emittance. In this paper, we report on recent linac studies, including beam stability and tolerances, longitudinal and transverse feedback systems, conventional and time-resolved diagnostics, and beam collimation systems. Construction and installation of the injector through first bunch compressor will be completed by December 2006, and electron commissioning is scheduled to begin in January of 2007.

2007-03-21

385

Subdural effusions in children under two years. Clinical and computer-tomographical data  

Energy Technology Data Exchange (ETDEWEB)

We investigated 161 children under 24 months of age by CT of the skull and reviewed the anamnestic and clinical history. 87 children showed subdural effusions, and 74 did not. There were 33 patients with other pathological findings in CT, and 41 had normal scans. Age and sex distribution as well as localization of the subdural effusions were consistent with the literature. The 87 children with subdural effusions represented 17% in a sample of about 5000 CT scans. CT was the most reliable method for diagnosis of subdural effusions, compared to other techniques. There was a preponderance of small subdural effusions from 1 to 7 mm thickness (51%). Other CT abnormalities accompanying subdural effusions were found. Most frequently the interhemispheric sulcus was dilated and an internal hydrocephalus was present. Also in our group there were 7 anamnestical and 6 clinical symptoms highly diagnostic of subdural effusions.

1980-05-01

386

Spontaneous radiation from relativistic electrons in a taper undulator. Technical report  

Science.gov (United States)

The spectrum, angular distribution, polarization and coherence properties of the radiation emitted by relativistic electrons undulating through a quasiperiodic tapered magnetic field are studied. Tapering the wavelength and/or field strength along the undulator's axis has the effect of spreading the spectral line to higher frequencies; interference over this broader spectral range results in a more complex line shape. The angular dependence, on the other hand, is not affected by the amount of taper. The polarization of the radiation in the forward direction is determined by the transverse polarization of the undulator, but the polarization changes off axis. The radiation patterns predicted here are distinct from those of untapered undulators, and their detection is now feasible. They will provide useful diagnostics of electron trajectories and threshold behavior in free-electron-laser oscillators using tapered undulators.

1983-06-01

387

Solute carrier transporters as targets for drug delivery and pharmacological intervention for chemotherapy  

British Library Electronic Table of Contents (United Kingdom)

Abstract Many solute carrier transporters that interact with anticancer agents and contribute to their pharmacokinetics have been shown to be differentially upregulated in cancer cells as a result of adaptive response to altered nutritional requirements. This review focuses on pathophysiological function of membrane transporters responsible for the influx of physiological substances including oligopeptides, amino acids, and organic cations and anions, and summarizes the recent knowledge regarding mechanisms in their gene expressions. Broad substrate specificity of enhanced oligopeptide H+/peptide cotransporter 1 activity in cancer cells is useful for tumor tissue-specific delivery of chemotherapeutic agents and positron emission tomography diagnostic probes. Amino acid transporters such as...

2011-01-01

388

Software development for a switch-based data acquisition system  

Energy Technology Data Exchange (ETDEWEB)

We report on the software aspects of the development of a switch-based data acquisition system at Fermilab. This paper describes how, with the goal of providing an integrated systems engineering'' environment, several powerful software tools were put in place to facilitate extensive exploration of all aspects of the design. These tools include a simulation package, graphics package and an Expert System shell which have been integrated to provide an environment which encourages the close interaction of hardware and software engineers. This paper includes a description of the simulation, user interface, embedded software, remote procedure calls, and diagnostic software which together have enabled us to provide real-time control and monitoring of a working prototype switch-based data acquisition (DAQ) system.

1991-12-01

389

Software development for a switch-based data acquisition system  

Energy Technology Data Exchange (ETDEWEB)

We report on the software aspects of the development of a switch-based data acquisition system at Fermilab. This paper describes how, with the goal of providing an ``integrated systems engineering`` environment, several powerful software tools were put in place to facilitate extensive exploration of all aspects of the design. These tools include a simulation package, graphics package and an Expert System shell which have been integrated to provide an environment which encourages the close interaction of hardware and software engineers. This paper includes a description of the simulation, user interface, embedded software, remote procedure calls, and diagnostic software which together have enabled us to provide real-time control and monitoring of a working prototype switch-based data acquisition (DAQ) system.

1991-12-01

390

Single Setting Bilateral Laparoscopic Orchiopexy for Bilateral Intra-Abdominal Testicles  

British Library Electronic Table of Contents (United Kingdom)

Purpose The laparoscopic surgical approach to unilateral intra-abdominal testis has replaced the open approach at several large centers. There is considerable literature on experience with unilateral intra-abdominal testes but little on the management of bilateral intra-abdominal testes. We assessed the feasibility and safety of performing single setting bilateral laparoscopic orchiopexy in boys with bilateral intra-abdominal testes. Materials and Methods A single surgeon experience was reviewed. The surgical technique was similar in all cases and on each side, including infra-umbilical access, diagnostic evaluation, peritoneal mobilization lateral to the spermatic vessels and inferior to the vas deferens, gubernacular transection, and a decision for or against a Fowler-Stephens procedure ...

2008-01-01

391

Sialography, echography and computed tomography in parotid gland study  

International Nuclear Information System (INIS)

The diagnostic accuracy of sialography and ultrasonography (US) in the evaluation of parotid masses is evaluated. Furthermore the role of computed tomography (CT) in this pathology is discussed. In the personal experience US proved to be the best method in the recognition of a parotid tumor while sialography was superior in defining the intra or extraparotid site. The two investigations showed the same accuracy in the definition of benign or malignant nature of the mass. Therefore we consider US the only investigation in most istances; sialography could be performed when the site of the lesion is uncertain or an inflammatory lesion is suspected. CT is never the first investigation; its use is limited to a low number of cases, mainly for the evaluation of large masses and when the association US-sialography does not allow a sure diagnosis.

1985-01-01

392

Role of MRI in the diagnostic evaluation of parotid diseases  

International Nuclear Information System (INIS)

MRI findings in 13 patients with monolateral parotid tumor were compared with US, sialographic and CT findings. MRI did not allow an accurate diagnosis in 2 patients with diffuse chronic parotitis. MRI was superior to CT in 1 case in defining the intraglandular site of the lesion, and in 2 patients in showing the extraglandular involvement. MRI proved to be superior to CT thanks to its contrast resolution and to multiplanar imaging. MRI high contrast resolution made it possible to demonstrate neoplastic lesions of 4 mm in diameter. The lesion has low signal intensity on T1-weighted images and high signal intensity on T2-weighted. Parotid tumors cannot be characterized by signal intensity alone: only morphology allows to discriminate between benign and malignant lesions. To conclude, US is a screening method, while MRI is helpful in detecting multifocal lesions and in evaluating the tumor extent.

1988-01-01

393

Reference values for X-ray diagnostic investigations. Some thoughts on the relation between expenditure and benefit; Referenzwerte fuer roentgendiagnostische Untersuchungen. Teil 2. Ueberlegungen zur Verhaeltnismaessigkeit von Nutzen und Aufwand  

Energy Technology Data Exchange (ETDEWEB)

In the first part of this contribution, the definition of reference values is given and the theoretical and practical problems in the application of this concept are discussed. In this connection, the present resources on instrumentation and the technical requirements for dose assessment are described. In the second part, some consequences are taken and proposals for further actions are made. (orig.) [German] Im ersten Teil des Aufsatzes werden Definitionen von Referenzwerten in der radiologischen Diagnostik untersucht und die theoretischen und praktischen Probleme der Umsetzung des gesamten Konzepts eroertert. In diesem Zusammenhang werden auch der gegenwaertige Geraetebestand und die technischen Voraussetzungen zur Dosisermittlung beschrieben. Im zweiten Teil werden daraus Schlussfolgerungen gezogen und Vorschlaege zum weiteren Vorgehen gemacht. (orig.)

2001-07-01

394

Reference values for X-ray diagnostic investigations. Some thoughts on the relation between expenditure and benefit; Referenzwerte fuer roentgendiagnostische Untersuchungen. T. 1. Ueberlegungen zur Verhaeltnismaessigkeit von Nutzen und Aufwand  

Energy Technology Data Exchange (ETDEWEB)

In the first part of this contribution, the definition of reference values is given and the theoretical and practical problems in the application of this concept are discussed. In this connection, the present resources on instrumentation and the technical requirements for dose assessment are described. In the second part, some consequences are taken and proposals for further actions are made. (orig.) [German] Im ersten Teil des Aufsatzes werden die Definition von Referenzwerten in der radiologischen Diagnostik untersucht und die theoretischen und praktischen Probleme der Umsetzung des gesamten Konzepts eroertert. In diesem Zusammenhang werden auch der gegenwaertige Geraetebestand und die technischen Voraussetzungen zur Dosisermittlung beschrieben. Im zweiten Teil werden daraus Schlussfolgerungen gezogen und Vorschlaege zum weiteren Vorgehen gemacht. (orig.)

2000-07-01

395

Real-time orbit feedback at the APS.  

Energy Technology Data Exchange (ETDEWEB)

A real-time orbit feedback system has been implemented at the Advanced Photon Source in order to meet the stringent orbit stability requirements. The system reduces global orbit motion below 30Hz by a factor of four to below 5{micro}m rms horizontally and 2{micro}m rms vertically. This paper focuses on dynamic orbit stability and describes the all-digital orbit feedback system that has been implemented at the APS. Implementation of the global orbit feedback system is described and its latest performance is presented. Ultimately, the system will provide local feedback at each x-ray source point using installed photon BPMs to measure x-ray beam position and angle directly. Technical challenges associated with local feedback and with dynamics of the associated corrector magnets are described. The unique diagnostic capabilities provided by the APS system are discussed with reference to their use in identifying sources of the underlying orbit motion.

1998-06-18

396

Radiopharmaceuticals labelled with positron emitting radionuclides  

International Nuclear Information System (INIS)

A brief survey is presented of the methods of preparation and of the applications of radiopharmaceuticals labelled with short-lived positron radionuclides "1"1C, "1"8F, "1"3N and "1"5O which, thanks to their energy level schemes, short half-life and the 511 keV photon radiation energy are almost ideal tracers in modern nuclear medicine and pharmacology. In conjunction with computerized tomography, they represent one of the most sensitive diagnostic imaging methods, the so-called positron emission tomography. In addition, their incorporation in the molecule of a pharmaceutical does not change the biological and chemical properties of the original molecule unlike those of radiopharmaceuticals labelled with technetium, iodine, etc. (author). 125 refs.

1989-01-01

397

Radiation Protection Aspects of the Linac Coherent Light Source Front End  

Energy Technology Data Exchange (ETDEWEB)

The Front End Enclosure (FEE) of the Linac Coherent Light Source (LCLS) is a shielding housing located between the electron dump area and the first experimental hutch. The upstream part of the FEE hosts the commissioning diagnostics for the FEL beam. In the downstream part of the FEE, two sets of grazing incidence mirror and several collimators are used to direct the beam to one of the experimental stations and reduce the bremsstrahlung background and the hard component of the spontaneous radiation spectrum. This paper addresses the beam loss assumptions and radiation sources entering the FEE used for the design of the FEE shielding using the Monte-Carlo code FLUKA. The beam containment system prevents abnormal levels of radiations inside the FEE and ensures that the beam remains in its intended path is also described.

2010-08-26

398

Prognostic value of plasma B-type natriuretic peptide in patients with severe cardiotoxic drug poisoning  

British Library Electronic Table of Contents (United Kingdom)

Background/Objectives: Cardiotoxic drug poisoning can lead to severe cardiac shock (CS) and death. B-type natriuretic peptide (BNP) is a well-established diagnostic and prognostic marker in heart failure but has never been assessed in patients with cardiotoxic drug poisoning. The aim of the study was to determine whether BNP could be useful for early stratification of patients admitted to intensive care unit. Methods: 30 consecutive patients experiencing shock and cardiotoxic drug exposure were enrolled in a prospective monocentric study and underwent at least two BNP measurements within the first 24 h after admission. Results: While BNP values on admission were poorly informative, subsequent BNP measurements (11 +- 6 h after admission) were significantly increased in patients with CS comp...

2011-01-01

399

Portal localization images using computed radiography for high-energy electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy electron beam therapy. (author)

2002-09-01

400

Plasma Diagnostics in the Optical and X-ray regions on the Plasma Focus device PF-4 (Installation TYULPAN)  

International Nuclear Information System (INIS)

The results of experiments received on the plasma focus (PF) device with energy stored equal 4 kJ are represented. Photos of the current plasma sheath (CPS), pre-pinch, sphere-like plasma formations are produced with help of the electron-optical converter contained a gated micro-channel plate (MCP) and the CCD-camera imaging system in the visible region. The redial velocity of the CPS is about 107 cm/s. Neon plasma electron density measured with help of the interferograms in the visible region and the spectra in the soft X-ray region is equals to 3?1018 cm-3. Electron temperature is equal to about 200 eV. Discharge integral photos were obtained with help of the soft X-ray pinhole camera. Pictures with 2 ?s resolution of the plasma luminescence above PF anode region were made by CCD-camera.

2006-01-01

401

Physical findings in the upper airways related to obstructive sleep apnea in men and women  

British Library Electronic Table of Contents (United Kingdom)

Conclusions. There are gender differences when it comes to the risk factors for sleep apnea. Large tonsils, a high tongue and a wide uvula are risk factors for sleep apnea in men, while large tonsils and a retrognathic mandible are risk factors in women. Upper airway abnormalities including mandibular retrognathia are, however, unable to predict sleep apnea among snorers being investigated for suspected sleep apnea. Objectives. To identify gender-specific risk factors for obstructive sleep apnea and the diagnostic performance from physical upper airway examinations among snoring men and women investigated because of suspected sleep apnea. Patients and methods. The dimensions of the uvula, tonsils, velopharynx and tongue, and nasal septal deviation, mandibular position, neck circumference, ...

2007-01-01

402

Peel-off case failure in thermal explosions observed by the deflagration cylinder test  

British Library Electronic Table of Contents (United Kingdom)

We have discovered a previously unidentified thermal explosion mode using the Los Alamos deflagration cylinder test (DFCT). The DFCT is a "pipe bomb"-style test similar to the detonation cylinder test (DTCT), which has been used for many years to calibrate detonation product equations of state. The shot is heated in an oven to a uniform test temperature. The pre-heated high explosive (HE) is triggered by a hot wire initiator on one end. The tube is back-illuminated by a bright light source, and its combustion-driven deformation and subsequent break-up are observed by a high-speed framing camera. Like the DTCT, the DFCT tube wall motion provides the primary diagnostic. A variety of reactive responses are possible, including quasi-steady deflagration and deflagration-to-detonation transition...

2009-01-01

403

Overview of Cooling Water System for the KSTAR 1st Plasma Experiment  

International Nuclear Information System (INIS)

The KSTAR cooling water system (CWS) consists of a primary cooling water system (PCWS), a secondary cooling water system (SCWS), and a de-mineralizing and de-ionized water system (DIWS). The PCWS cooling loops have been made for the poloidal field (PF) and toroidal field (TF) magnet power supplies (MPS), vacuum vessel (VV), electron cyclotron heating (ECH), ion cyclotron heating (ICRH), vacuum pumps, diagnostics, helium facility, etc. The CWS had been done individual commissioning of each system to confirm the design specifications by the end of 2006 and had gradually begun operation for the KSTAR ancillary devices by March 2008

2009-05-01

404

Morphology of the first instar of Calliphora vicina, Phormia regina and Lucilia illustris (Diptera, Calliphoridae)  

British Library Electronic Table of Contents (United Kingdom)

Abstract. Scanning electron microscopy documentation of first instar Calliphora vicina Robineau-Desvoidy, Phormia regina (Meigen) and Lucilia illustris (Meigen) (Diptera: Calliphoridae) is presented for the first time, and the following morphological structures are documented: pseudocephalon; antenna; maxillary palpus; facial mask; labial lobe; thoracic and abdominal spinulation; spiracular field; posterior spiracles, and anal pad. Light microscopy documentation and illustrations are provided for the cephaloskeleton in lateral and ventral views. New diagnostic features are revealed in the configuration of the facial mask, cephaloskeleton and posterior spiracles. The first instar morphology of C. vicina, Ph. regina and L. illustris is discussed in the light of existing knowledge about early...

2008-01-01

405

Monoclonal antibodies: new agents for cancer detection and targeted therapy  

International Nuclear Information System (INIS)

Antibodies directed against markers on cancer cells are gaining in importance for the purpose of targeting diagnostic and therapeutic agents. In the past, this approach has had very limited success principally because the classical methods for producing antibodies from blood serum of animals immunized with cancer cells or extracts were unsatisfactory. The situation has changed dramatically since 1975 following the design of procedures for 'immortalizing' antibody-producing cells (lymphocytes) by fusing them with cultured myeloma cells to form hybridomas which continuously secrete antibodies. Since these hybridomas produce antibodies coded for by a single antibody-producing cell, the antibodies are called monoclonal. Building on these advances in biomedical research, it is now possible to reproducibly manufacture monoclonal antibodies on a scale suitable for use in cancer detection and therapy.

406

Methods for proving the equivalency of detonator performance  

Energy Technology Data Exchange (ETDEWEB)

One of the challenges facing engineers is developing newer, safer detonators that are equivalent to devices currently in use. There is no clear consensus on an exact method for drawing equivalence of detonators. This paper summarizes our current efforts to develop diagnostics addressing various aspects of detonator design to better quantify and prove equivalency. We consider various optical techniques to quantify the output pressure and output wave shape. The development of a unique interpretation of streak camera breakouts, known as the apparent center of initiation, will be discussed as a metric for detonation wave shape. Specific examples apply these techniques to the comparison of a new laser-driven detonator with an existing exploding bridgewire (EBW) detonator. Successes and short-comings of the techniques will be discussed.

2009-01-01

407

Metastatic breast carcinoma to parathyroid adenoma on fine needle cytology sample: Report of a case  

British Library Electronic Table of Contents (United Kingdom)

Abstract Metastases to the thyroid gland diagnosed by means of fine needle cytology or by excision have been reported in the literature. To our knowledge, metastatic neoplasms to the parathyroid gland have never been described up to now. In this article, we introduce a rare case of metastatic breast carcinoma to a parathyroid adenoma in a 56-year-old woman, which clinically simulated a left thyroid nodule. The patient had a history of left breast carcinoma; the recent discovery of a palpable mass in the left thyroid area had elicited fine needle cytology sampling for its diagnostic evaluation. The obtained cytopathological sample was cellular but limited to a single Diff-Quik-stained smear; hence, no ancillary studies could be entertained. A cytopathological diagnosis of positive for malig...

2011-01-01

408

Linac Coherent Light Source Longitudinal Feedback Model  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL). To ensure the vitality of FEL lasing, it is critical to preserve the high quality of the electron beam during acceleration and compression. The peak current and final energy are very sensitive to system jitter. To minimize this sensitivity, a longitudinal feedback system on the bunch length and energy is required, together with other diagnostics and feedback systems (e.g., on transverse phase space). Here, we describe a simulation framework, which includes a realistic jitter model for the LCLS accelerator system, the RF acceleration, structure wakefield, and second order optics. Simulation results show that to meet the tight requirements set by the FEL, such a longitudinal feedback system is mandatory.

2005-06-15

409

Leadership as engagement, leadership as system development: A contextualised Ghanaian study  

British Library Electronic Table of Contents (United Kingdom)

Purpose - This paper uses data about the challenges and difficulties confronting organisations and leaders to advance a dualized meaning of corporate leadership in the context of a developing country. The purpose is to describe a leadership frame that is locally contextualised, thereby bringing conceptualisation and thought closer to action, reified reality and applicability. Design/methodology/approach - This research was designed as a series of three studies starting from an applied/interventionist standpoint. The first study used data from applied diagnostic interventions, the second used qualitative interviews and the third used open-ended questionnaires. Data were collected from 25 Ghanaian organisations and 29 corporate executives. Findings - Drawing on a range of everyday issues suc...

2010-01-01

410

Laparoscopic approach of a nonparasitic splenic cyst; Abordagem videolaparoscopica de cisto esplenico nao parasitario  

Energy Technology Data Exchange (ETDEWEB)

A rare case of primary splenic cyst is shown in a young woman who had a left subcostal abdominal pain. Abdominal echography and CT scan revealed a cyst of the anterior aspect of the spleen. A sorologic test for hidatic disease was negative. On the basis of a presumed diagnostic of nonparasitic cyst, the patient was referred to a laparoscopic decapsulation with excision of the cysts wall not covered by splenic tissue. The patient was discharged 24 hours later. Histological report revealed epidermoid cyst. The laparoscopic approach has being recently considered an effective and less invasive alternative in the treatment of splenic diseases. We demonstrated that it should be considered for the treatment of splenic cysts present in a superficial location, with the advantage of organ preservation. (author)

2000-10-01

411

Iopentol in cardioangiography  

International Nuclear Information System (INIS)

Iopentol (350 mg I/ml) has been compared with iohixol (350 mg I/ml) in a double-blind randomized parallel group trial with 32 and 35 patients receiving iopentol and iohexol, respectively. Coronary angiography and left ventriculography were performed, and the mean total volume injected was 124 ml of iopentol and 135 ml of iohexol . There were no statistically significant differences regarding changes in heart rate and frequency of adverse advents, which were the primary parameters, between the two groups of patients. Blood pressure and ECG parameters revealed only minor fluctuations which were of no clinical relevance. The visualization of the coronary arteries and the left ventricle were the same with both contrast media, as was the diagnostic quality. The results support the use of iopentol in cardioangiography. (author). 1 ref.; 5 tabs.

412

Inflammatory spine disease as a cause of back pain  

International Nuclear Information System (INIS)

The aim of this review is to evaluate the role of inflammatory spine disease in patients with chronic back pain. The contribution of imaging modalities for the diagnostic evaluation of back pain is discussed. A systematic literature search based on the classification of seronegative spondyloarthropathies and rheumatoid arthritis was performed. The results of this search and the experiences in a large collective of rheumatological patients are analyzed. The prevalence of rheumatoid arthritis (1-2%) is comparable to that of spondyloarthropathies (1.9%). The etiology of these entities is not fully elucidated. Magnetic resonance imaging is increasingly used for early detection and surveillance of therapy with TNF-#alpha# antagonists. Bone marrow edema, which is only detectable with MRI, represents an early sign of inflammation. Therapy with TNF-#alpha# antagonists is based on clinical and laboratory criteria, and signs of inflammation in MRI. MRI is useful for ...

2006-06-01

413

Improving performance and availability by means of steam turbine diagnoses; Steigerung von Wirkungsgraden und Verfuegbarkeit durch Dampfturbinen-Diagnose  

Energy Technology Data Exchange (ETDEWEB)

Diagnostic systems make it possible to recognize incipient faults in good time and help to increase the availability of power stations. The thermal efficiency and the effective terminal output are didicated by a number of influences. Deviations from the expected status can be identified via continuous recording of the operating parameters and calculation of derived data. An improved efficiency and economical load distribution lead to considerable cost savings. (orig.) [Deutsch] Die Verarbeitung von Messwerten und Signalen ermoeglicht eine umfassende Beurteilung des Anlagenzustandes und die Erkennung sich anbahnender Veraenderungen. Stoerungen, Schaeden oder eine unwirtschaftliche Betriebsweise koennen fruehzeitig erkannt werden. Erhoehte Verfuegbarkeit, geringerer Brennstoffverbrauch und optimierte Lastaufteilung bringen Kostenvorteile. (orig.)

1996-12-31

414

Identifying fade mechanisms in high-power lithium-ion cells.  

Energy Technology Data Exchange (ETDEWEB)

Hybrid electric vehicles (HEV) need long-lived high-power batteries as energy storage devices. Batteries based on lithium-ion technology can meet the high-power goals but have been unable to meet HEV calendar-life requirements. As part of the US Department of Energy's Advanced Technology Development (ATD) Program, diagnostic studies are being conducted on 18650-type lithium-ion cells that were subjected to accelerated aging tests at temperatures ranging from 40 to 70 C. This article summarizes data obtained by gas chromatography, liquid chromatography, electron microscopy, X-ray spectroscopy and electrochemical techniques, and identifies cell components that are responsible for the observed impedance rise and power fade.

2004-01-01

415

Identification of prostate cancer antigens by automated high-throughput filter immunoscreening  

British Library Electronic Table of Contents (United Kingdom)

There is a need for earlier and more accurate cancer diagnostics as well as new targets for cancer immunotherapy. To this end, it is important to identify sets of tumour antigens specific for different cancer forms. Several methods that identify potential tumour antigens in an arrayed and high-throughput format have been developed during the last years of SEREX (serological identification of antigens by recombinant expression cloning) related research. Such techniques may hold the potential to describe the complete immunogenic part of the cancer proteome, also called the cancer immunoproteome.We have developed a powerful platform for automated serological high-throughput filter screening of tumour cDNA libraries. The screening format of this method is 18,000 single cDNAs clones, which is s...

2008-01-01

416

Idealized gas turbine combustor for performance research and validation of large eddy simulations.  

Science.gov (United States)

This paper details the design of a premixed, swirl-stabilized combustor that was designed and built for the express purpose of obtaining validation-quality data for the development of large eddy simulations (LES) of gas turbine combustors. The combustor features nonambiguous boundary conditions, a geometrically simple design that retains the essential fluid dynamics and thermochemical processes that occur in actual gas turbine combustors, and unrestrictive access for laser and optical diagnostic measurements. After discussing the design detail, a preliminary investigation of the performance and operating envelope of the combustor is presented. With the combustor operating on premixed methane/air, both the equivalence ratio and the inlet velocity were systematically varied and the flame structure was recorded via digital photography. Interesting lean flame blowout and resonance characteristics were observed. In addition, the combustor exhibited a large region of ...

2007-03-01

417

High-energy x-ray microscopy techniques for laser-fusion plasma research at the National Ignition Facility  

Energy Technology Data Exchange (ETDEWEB)

Multi-kilo-electron-volt x-ray microscopy will be an important laser-produced plasma diagnostic at future megajoule facilities such as the National Ignition Facility (NIF). However, laser energies and plasma characteristics imply that x-ray microscopy will be more challenging at NIF than at existing facilities. We use analytical estimates and numerical ray tracing to investigate several instrumentation options in detail, and we conclude that near-normal-incidence single spherical or toroidal crystals may offer the best general solution for high-energy x-ray microscopy at NIF and similar large facilities. Apertured Kirkpatrick{endash}Baez microscopes using multilayer mirrors may also be good options, particularly for applications requiring one-dimensional imaging over narrow fields of view. {copyright} 1998 Optical Society of America

1998-04-01

418

Hepatosplenic T-cell lymphoma is a distinct rare entity: Diagnosis by fine-needle aspiration cytology  

British Library Electronic Table of Contents (United Kingdom)

Abstract In this brief report, we have described the fine-needle aspiration cytology (FNAC) of a hepatosplenic T-cell lymphoma (HSTCL) in a 60-year-old female patient. The patient complained of fever and heaviness of left upper abdomen. Ultrasound-guided FNAC of the spleen showed immature lymphoid cells, and a diagnosis of primary non-Hodgkin lymphoma of spleen was offered. Subsequently, the patient underwent splenectomy and wedge biopsy of liver that confirmed the cytological diagnosis. The lymphoma cells were positive for CD3 immunostain. Primary hepatosplenic T-cell lymphoma is a rare entity and may often pose diagnostic problems on FNAC. Diagn. Cytopathol. 2010. 2010 Wiley-Liss, Inc.

2011-01-01

419

Follow-up and diagnosis of recurrences after radio-chemotherapy of malignant head and neck tumors  

International Nuclear Information System (INIS)

339 CT und 95 MRT examinations in 210 partients were evaluated retrospectively to determine the value of CT and MRT for follow-up of head and neck tumors and for diagnosing recurrences. Semi-quantitative evaluation of tumor extent during and after radiotherapy showed advantages for MRT since changes induced by treatment, particularly oedema, produced less contrast loss in the images. CT had a sensitivity of 81% for the recognition of recurrences; this was 92% for MRT. Specificity for CT was 76% and for MRT 86%. Concerning the reliability of individual diagnostic criteria, space occupying lesions were the most valuable in CT diagnosis. For MRT, space occupying lesions and infiltration into neighbouring structures were of equal value. Because of differences in the nature of the signals, MRT proved better than CT in characterising recurrent masses and this improved the differentiation between scarring and local tumour recurrence. (orig.).

420

Fault diagnosis on bottle filling plant using genetic-based neural network  

British Library Electronic Table of Contents (United Kingdom)

Timely detection of the pneumatic system problems is important in industry. Many techniques have been employed to solve this problem. In this paper, Genetic Algorithm (GA) based optimal configuration of neural networks is proposed for fault diagnostic of bottle filling systems. Back-propagation is used for neural networks algorithm. The back-propagation algorithm had six inputs and one output. A fitness function was designed to the minimize execution time of ANN model by keeping the number of hidden layer(s) and nodes as low as possible while the mean square error of estimated output error is minimized. The designed GA-ANN combination and the graphical user interface (GUI) eliminate the trial and error process for selection of the fastest and most accurate configuration. The performance of...

2011-01-01

421

Fault detection and diagnosis of a gearbox in marine propulsion systems using bispectrum analysis and artificial neural networks  

British Library Electronic Table of Contents (United Kingdom)

A marine propulsion system is a very complicated system composed of many mechanical components. As a result, the vibration signal of a gearbox in the system is strongly coupled with the vibration signatures of other components including a diesel engine and main shaft. It is therefore imperative to assess the coupling effect on diagnostic reliability in the process of gear fault diagnosis. For this reason, a fault detection and diagnosis method based on bispectrum analysis and artificial neural networks (ANNs) was proposed for the gearbox with consideration given to the impact of the other components in marine propulsion systems. To monitor the gear conditions, the bispectrum analysis was first employed to detect gear faults. The amplitude-frequency plots containing gear characteristic sign...

2011-01-01

422

Explosive performance on the non-proliferation experiment  

Energy Technology Data Exchange (ETDEWEB)

The non-proliferation experiment, originally called the chemical kiloton experiment, was planned and executed by Lawrence Livermore National Laboratory to investigate the seismic yield relationship and distinguishing seismic signals between a nuclear event and a large mass conventional explosion. The Los Alamos National Laboratory planned and conducted experiments to further their studies of the source function for signals observed seismically. Since all investigations were contingent on the performance of the emplaced chemical explosive, an array of diagnostic measurements was fielded in the emplaced explosive. The CORRTEX system was used to investigate the explosive initiation and to determine the detonation velocities in multiple levels and in numerous directions. A description of the CORRTEX experiments fielded, a review of the data obtained and some interpretations of the data are reported.

1994-03-01

423

Exploiting unique germplasm resources of leguminous trees: Prosopis, leucaena and acacia. Final report, August 31, 1982-August 30, 1992  

Energy Technology Data Exchange (ETDEWEB)

In Haiti, and other semiarid regions of the world, the need for fuelwood and forage is critical. The report summarizes research conducted over a ten year period on developing replicable plantations of leguminous trees in semiarid lands, especially in areas near seawater salinity levels. Research included greenhouse and laboratory work followed by field trials in Haiti and focused on two species: Prosopis and Leucaena. (Acacia is mentioned in the report's title but not in the report itself.) Results were as follows. (1) Greenhouse experiments identified leaf diagnostic criteria indicating mineral nutrient deficiencies in field trees. It also established the importance of micronutrients, especially zinc, in permitting growth in high pH (9.0) soils.

1992-01-01

424

Excitation of global Alfven Eigenmodes by RF heating in JET  

Energy Technology Data Exchange (ETDEWEB)

The alpha-particle confinement of future D-T experiments at JET can be severely degraded by Global Alfven Eigenmodes (AE). Scenarios for the excitation of Alfven Eigenmodes in usual (e.g. D-D) plasmas are proposed, which provide a MHD diagnostic and allow the study of the transport of super-Alfvenic ions. Active studies with separate control of TAE amplitude and energetic particle destabilization, measuring the plasma response, give more information than passive studies, in particular concerning the damping mechanisms. The TAE excitation can be achieved by means of the saddle coil and the ICRH antenna. The experimental method is introduced together with a theoretical model for RF excitation. (authors). 6 refs., 3 figs.

1994-07-01

425

Evaluation of diagnostic digital radiography of the chest in comparison with conventional chest x-ray films  

International Nuclear Information System (INIS)

Digital radiography for diagnosis of chest diseases using Fuji Computed Radiography (FCR) was evaluated. The results were as follows; 1. Compared to the conventional chest X-ray films, various types of image enhancement could be made by manipulation of the digital information such as tone conversion, spatial frequency modification etc. 2. Digital radiography lessens the X-ray exposure dose and will ultimately permit speedy transmission of image data from outlying clinics to central processing hospitals. 3. Digital radiographic images are useful in chest X-ray diagnosis especially in mass surveys for lung cancer and in primary care medicine because of its full imaging capability. (author).

1983-01-01

426

Evaluation of a commercial MRSA assay when multiple MRSA strains are causing epidemics  

British Library Electronic Table of Contents (United Kingdom)

Rapid and reliable diagnostic methods are needed to control methicillin-resistant Staphylococcus aureus (MRSA) transmission. We studied the BD GeneOhm? MRSA Assay which is based on one specific amplification product at the junction of the right extremity sequence of the staphylococcal cassette chromosome mec (SCCmec) and the chromosomal sequence of orfX of S. aureus. The test was applied on 95 clinical isolates in Finland: 83% were positive. The isolates giving negative results represented several pulsed-field gel electrophoresis (PFGE) types and harboured SCCmec types IV, V, VI or were new types with different combinations of ccr genes.

2009-01-01

427

Estimating personal costs incurred by a woman participating in mammography screening in the National Breast and Cervical Cancer Early Detection Program  

British Library Electronic Table of Contents (United Kingdom)

BACKGROUND.The National Breast and Cervical Cancer Early Detection Program (NBCCEDP) covers the direct clinical costs of breast and cervical cancer screening and diagnostic follow-up for medically underserved, low-income women. Personal costs are not covered. In this report, the authors estimated personal costs per woman participating in NBCCEDP mammography screening by race/ethnicity and also estimated lifetime personal costs (ages 50-74 years).METHODS.A decision analysis model was constructed and parameterized by using empiric data from a retrospective cohort survey of mammography rescreening among women ages 50 years to 64 years who participated in the NBCCEDP. Data from 1870 women were collected from 1999 to 2000. The model simulated the flow of resources incurred by a woman participat...

2008-01-01

428

Endoscopic snare papillectomy with biliary and pancreatic stent placement for tumors of the major duodenal papilla  

British Library Electronic Table of Contents (United Kingdom)

Background This study aimed to evaluate the feasibility, safety, and follow-up results of endoscopic papilletomy (ESP) with pancreatic and biliary duct stent placement for ampullary tumors. The therapeutic approach to benign ampullary tumors remains unsettled. The ESP procedure is a curative treatment option for benign papillary tumors, but ESP raises concerns about a relatively high risk for procedure-related complications such as pancreatitis. A pancreatic stent may protect against complications. Methods Between September 2000 and June 2008, 36 patients with ampullary tumors confined to the mucosa and no intraductal tumor growth underwent ESP. The preprocedural diagnostic tools included endoscopic ultrasound, transpapillary intraductal ultrasound, and endoscopic retrograde cholangiopancr...

2010-01-01

429

Electron accelerators, present and future applications  

International Nuclear Information System (INIS)

The development and occurrence of new electron accelerators and applications are according to the human society development law, as a whole. The period of economic standstill is generating an intense creative activity in the domain of science and engineering which also resulting in great achievements in the field of electron accelerators. This paper presents the basic principle of the electron beam applications and the accelerators required characteristics for their present and potential applications in the domains: radiation sources, diagnostics, radiation processing, energetics, environment, defense and basic sciences. All these are correlated to the new generation of accelerators which, for the acceleration process, may employ electromagnetic fields generated by standard sources, atomic lasers, free electron lasers, Cerenkov effect, Smith - Purcell effect, electron beams, plasma, excited atoms into a crystal or other sources. Some more important applications in ...

430

Early spondyloarthropathy: scintigraphic, biological, and clinical findings in MRI-positive patients  

British Library Electronic Table of Contents (United Kingdom)

There are no specific diagnostic tests or a gold standard method for measuring disease activity and outcome in spondyloarthropathies (SpA). Many different methods have been developed to assess the signs and symptoms in SpA. The aim of this study was to evaluate the value of scintigraphy, erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), and Bath Ankilosing Spondylitis Disease Activity Index (BASDAI) in the evaluation of disease activity in early axial SpA diagnosed with magnetic resonance imaging (MRI). Thirty early MRI-positive axial SpA patients (23 males, 7 females) with a median age of 35 (18?55) years and a median duration of inflammatory low back pain of 24 (8?60) months were included in the study. In the patients with sacroiliitis, the sensitivity, specificity, and pos...

2008-01-01

431

EBIT - Electronic Beam Ion Trap: N Divison experimental physics annual report 1995  

Energy Technology Data Exchange (ETDEWEB)

The multi-faceted research effort of the EBIT (Electron Beam Ion Trap) program in N-Division of the Physics and Space Technology Department at Lawrence Livermore National Laboratory (LLNL) continues to contribute significant results to the physical sciences from studies with low energy very highly charged heavy ions. The EBIT program attracts a number of collaborators from the US and abroad for the different projects. The collaborations are partly carried out through participating graduate students demonstrating the excellent educational capabilities at the LLNL EBIT facilities. Moreover, participants from Historically Black Colleges and Universities are engaged in the EBIT project. This report describes EBIT work for 1995 in atomic structure measurements and radiative transition probabilities, spectral diagnostics for laboratory and astrophysical plasmas, ion/surface interaction studies, electron-ion interactions studies, retrap and ion collisions, and ...

1996-10-01

432

Dimensions and Latent Classes of Episodic Mania-Like Symptoms in Youth: An Empirical Enquiry  

British Library Electronic Table of Contents (United Kingdom)

The dramatic increase in diagnostic rates of bipolar disorder in children and adolescents in the USA has led to an intense interest in the phenomenology of the disorder. Here we present data from a newly-developed instrument to assess episodic mania-like symptoms in youth in a large population-based sample (N?=?5326) using parent- and self-report. We found that a substantial proportion of children screened positive for having episodes of ?going high? and were at an increased risk for morbidity and impairment. Using factor analysis, we identified that episodic mania-like symptoms comprised two dimensions: An under-controlled dimension that was associated with significant impairment, and a low-risk exuberant dimension. Using latent class analysis, we identified a small group of children scor...

2011-01-01

433

Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)  

Energy Technology Data Exchange (ETDEWEB)

Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical conditions were determined. (author).

1991-12-01

434

Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)  

International Nuclear Information System (INIS)

Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical conditions were determined. (author).

1991-01-01

435

Diagnostic and Prognostic Utility of t(14;18) in Follicular Lymphoma  

British Library Electronic Table of Contents (United Kingdom)

Abstract Background: Follicular lymphoma (FL) is one of the most common non-Hodgkin's lymphomas of B cells, being closely associated with a t(14;18) translocation. Detection of t(14;18), which is present in 70-95% of FL, might aid in FL diagnosis. Objective: To compare the efficacy of routine polymerase chain reaction (PCR) and fluorescence in situ hybridization (FISH) techniques in detecting t(14;18) in paraffin-embedded tissue samples of FL patients at different stages. Combined with other immunophenotypic biological determinants, detection of t(14;18) might help to determine patients at increased risk according to the FL International Prognostic Index (FLIPI) and therefore facilitate appropriate treatment. Design and Methods: This study was mainly based on a retrospective examination of...

2007-01-01

436

Detection of Microcalcification in Mammograms Using Wavelet Transform and Fuzzy Shell Clustering  

CERN Document Server

Microcalcifications in mammogram have been mainly targeted as a reliable earliest sign of breast cancer and their early detection is vital to improve its prognosis. Since their size is very small and may be easily overlooked by the examining radiologist, computer-based detection output can assist the radiologist to improve the diagnostic accuracy. In this paper, we have proposed an algorithm for detecting microcalcification in mammogram. The proposed microcalcification detection algorithm involves mammogram quality enhancement using multirresolution analysis based on the dyadic wavelet transform and microcalcification detection by fuzzy shell clustering. It may be possible to detect nodular components such as microcalcification accurately by introducing shape information. The effectiveness of the proposed algorithm for microcalcification detection is confirmed by experimental results.

2010-01-01

437

Deposition of amino-rich coatings by RF magnetron sputtering of Nylon: Investigation of their properties related to biomedical applications  

British Library Electronic Table of Contents (United Kingdom)

Amino-rich polymeric coatings are widely used in biomedical applications, since they promote adsorption of diverse biomolecules or facilitate cell growth. As a consequence, there is a growing interest in fabrication of such coatings that is focused predominantly on the optimization of the deposition process in terms of high density of primary amino groups. In addition, the nature of biomedical applications requires also sufficient stability of the films in aqueous environments. This aspect is investigated in this contribution. In particular, the effect of water and phosphate buffer saline on the coatings prepared by RF magnetron sputtering of Nylon 6,6 in Ar/N2 and N2/H2 gas mixtures is evaluated. The samples exposed to liquids are characterized by various diagnostic methods and their prop...

2011-01-01

438

Correlation of myocardial TC-99m-MIBI perfusion SPECT with coronary angiography in Namazi hospital  

International Nuclear Information System (INIS)

Coronary heart disease is the leading cause of death specially among elderly. Coronary angiography is the best diagnostic method in the patients, but is unfortunately an invasive procedure with its inherent risks. Myocardial perfusion scan is a noninvasive and sensitive method for evaluation of Coronary artery disease and is suggested by many investigators in recent years. In this study, 64 patients who had a Tc99m-MIBI SPECT myocardial perfusion study at our department, underwent coronary angiography within 4 months. Correlation of the methods revealed that SPECT Tc99m -MIBI had a high sensitivity and specificity in our hand, which is comparable with international findings.

2004-04-27

439

Condition monitoring and optimization of a 340 MW re-powered combined cycle plant. Part 1: Design  

Energy Technology Data Exchange (ETDEWEB)

This paper focuses on the application and features of a unified multi-machine train condition monitoring and diagnostic system as applied to a 340 MW repowered combined cycle power plant. Modifications during repowering of the plant required the addition of gas turbines, and design changes to the boiler and steam turbine. Operational procedure during startup also had to be developed. In order to improve the economics of operation, enhancement of both plant operational efficiency and availability were required. Thus it was decided to implement an on-line plant-wide multi-machine Condition Monitoring System. In this paper, the details of the condition monitoring system and some of the design details of the power plant are presented. Requirements of a condition monitoring system applicable to a combined cycle plant are also covered. Salient system design features are explained. The system has been implemented in a combined cycle plant at Bergum, The Netherlands.

1994-12-31

440

Clinical Characteristics of Children Receiving Antipsychotic Medication  

British Library Electronic Table of Contents (United Kingdom)

Abstract This study explored the demographic and diagnostic features of children who were currently receiving antipsychotics compared to children who were receiving other psychotropics in a cohort of children with and without elevated symptoms of mania (ESM). Participants were recruited from 10 child outpatient mental health clinics associated with four universities. Guardians with children between 6?12 years who presented for new clinical evaluations completed the Parent General Behavior Inventory-10 Item Mania Scale (PGBI-10M). All children who scored ?12 on the PGBI-10M and a select demographically matched comparison group of patients who scored ?11 were invited to participate. Children were divided into two groups: those receiving at least one antipsychotic medication and those receivi...

2011-01-01

441

Cancer-cell-specific cytotoxicity of non-oxidized iron elements in iron core-gold shell NPs  

British Library Electronic Table of Contents (United Kingdom)

Gold-coated iron nanoparticles (NPs) selectively and significantly (P <0.0001) inhibit proliferation of oral- and colorectal-cancer cells in vitro at doses as low as 5 mg/mL, but have little adverse effect on normal healthy control cells. The particle treatment caused delay in cell-cycle progression, especially in the S-phase. There was no significant difference in the NP uptake between cancer and control cells, and cytotoxicity resulted primarily from the iron core, before oxidation, rather than from the Fe ions released from the core. In contrast with magnetic NPs that usually serve as drug carriers, diagnostic probes or hyperthermia media, the iron, before oxidation, in the NPs selectively suppressed cancer cell growth and left healthy control cells unaffected in vitro and in vivo. This...

2011-01-01

442

Calcified metastases of the kidney. Etiology, pathogenesis, CT findings and diagnostic problems; Metastasi renali calcificate: eziologia, patogenesi, aspetti con tomografia computerizzata e diagnostica differenziale  

Energy Technology Data Exchange (ETDEWEB)

Aim of the work was to describe computerised tomography (CT) findings of calcified renal metastases focusing on differential diagnosis problems. Abdominal CT scans of 8000 patients with tumor, performed from 1984 to 1998, have been retrospectively reviewed. [Italian] Scopo del lavoro e' quello di descrivere gli aspetti con tomografia computerizzata delle metastasi renali calcificate enfatizzando le problematiche diagnostico differenziali. Sono state valutate retrospettivamente le indagini TC addominali di 8000 pazienti affetti da tumore nel periodo 1984-1998, analizzando le lesioni calcificate riscontrate.

2000-03-01

443

CF findings of bowel infarction in 56 surgical patients, 5 of whom with reversible ischemia  

International Nuclear Information System (INIS)

Bowel infarction is a rare and typical condition of the elderly; despite improvements in diagnostic imaging and vascular surgery, bowel infarction remains a major cause of acute abdomen, with mortality rates ranging 70-80%. Diagnosis on often late because clinical sings, laboratory data and radiologic findings are a specific. The authors investigated radiographic and particular CT patterns of intestinal infraction in 56 patients submitted to surgery within 12 hours of admission. We also report the CT findings of 5 of these patients who had reversible mesenteric ischemia. CT is more sensitive than radiography and does not exhibit the limitations of angiography (i.e., invasiveness, radiation exposure an complex organization. Therefore CT can presently be considered the method of choice in patients with suspected bowel infarction.

1999-04-01

444

Biomarkers for infants at risk for necrotizing enterocolitis: clues to prevention?  

Science.gov (United States)

Necrotizing enterocolitis (NEC) is the most common severe gastrointestinal emergency that affects premature newborns. This disease often has a rapid onset with few, if any, antecedent signs that can be used to reliably predict its occurrence. Its rapid onset and progression to death, as well as its severe morbidity when the infant survives, begs for early diagnostic tools that may be used in determining those infants who would be at greatest risk for development of the disease and for whom early preventative measures could be targeted. Although studies have suggested efficacy of several techniques such as breath hydrogen, inflammatory mediators in blood, urine or stool, and genetic markers, these all have drawbacks limiting their use. The application of newly developed "omic" approaches may provide biomarkers for early diagnosis and targeted prevention of this disease. PMID:19190533

2009-05-01

445

Bars and Boxy\\/Peanut-Shaped Bulges An Observational Point of View  

CERN Document Server

Prompted by work on the buckling instability in barred spiral galaxies, much effort has been devoted lately to the study of boxy/peanut-shaped (B/PS) bulges. Here, we present new bar diagnostics for edge-on spiral galaxies based on periodic orbits calculations and hydrodynamical simulations. Both approaches provide reliable ways to identify bars and their orientations in edge-on systems. We also present the results of an observational search for bars in a large sample of edge-on spirals with and without B/PS bulges. We show that most B/PS bulges are due to the presence of a thick bar viewed edge-on while only a few may be due to accretion. This strongly supports the bar-buckling mechanism for the formation of B/PS bulges.

1999-01-01

446

Adrenal incidentaloma: Does an adequate workup rule out surprises?  

British Library Electronic Table of Contents (United Kingdom)

Background Adrenal incidentaloma remains a diagnostic challenge. Despite well-established management guidelines, the long-term results of following these guidelines are unknown. We sought to determine how accurately these guidelines identify functioning incidentalomas and how often these guidelines result in adrenalectomy for benign tumors. Methods We catalogued adrenal incidentalomas from a retrospective review of 500 consecutive adrenalectomies at a single institution. The outcome measures studied were patient demographics, preoperative biochemical analysis, imaging characteristics, tumor size, type of operation performed, and postoperative histologic diagnosis. Results Eighty-one of the 500 adrenalectomies performed were for incidentalomas. Size was the only significant characteristic t...

2010-01-01

447

Adenopathies in lung cancer: a comparison of pathology, Computed Tomography and endoscopic ultrasound findings  

International Nuclear Information System (INIS)

A prospective comparative study with pathology was performed to assess the clinical value of Computed Tomography (CT) and endoscopic ultrasound (EUS) for nodal staging in lung cancer. A total of 329 nodal stations were dissected or sampled and 755 lymph nodes were examined at histology. On a pre-station basis, CT had greater sensitivity (74%) than EUS (56%), but EUS was more specific (83% versus 93%). The accuracy rates of the two techniques were similar. In conclusion, endoscopic ultrasound should be part of a routine preoperative diagnostic approach to non-small-cell lung cancer., because of its high specificity. Results can be improved when EUS and CT are combined., which suggests that these imaging modalities should be used together in selected patients for the noninvasive staging of non-small-cell lung cancer to identify local lymphatic spread.

1999-01-01

448

A real-time neutron radiography diagnostic of a vertical co-current two-phase flow channel with a hexagonal finned bundle  

International Nuclear Information System (INIS)

A Real-Time Neutron Radiography (RTNR) system is developed to determine two-phase flow parameters for a vertical co-current two-phase flow channel with a hexagonal finned bundle. Image processing techniques are applied to visualize the two-phase flow, and procedures for measuring flow regime, cross-sectional averaged void fraction, time averaged void fraction, and void distribution for this complex geometry are discussed. The results show that the experimental flow regime map agrees well with an existing flow regime model for a hexagonal fined bundle. The hexagonal finned bundle is observed to significantly affect the void fraction, void migration, and void fluctuation along the axial flow channel.

2003-06-01

449

A pump-probe XFEL particle injector for hydrated samples  

CERN Document Server

We have developed a liquid jet injector system that can be used for hydrated sample delivery at X-ray Free Electron Laser (XFEL) sources and 3rd generation synchrotron sources. The injector is based on the Gas Dynamic Virtual Nozzle (GDVN), which generates a liquid jet with diameter ranging from 300 nm to 20 {\\mu}m without the clogging problems associated with conventional Rayleigh jets. An improved nozzle design is presented here. A differential pumping system protects the vacuum chamber and an in-vacuum microscope allows observation of the liquid jet for diagnostics while it is being exposed to the X-ray beam. A fiber optically coupled pump laser illuminating the jet is incorporated for pump-probe experiments. First results with this injector system have been obtained at the LCLS.

2011-01-01

450

A preliminary study of sleep in adolescents with bipolar disorder, ADHD, and non-patient controls  

British Library Electronic Table of Contents (United Kingdom)

Mullin BC, Harvey AG, Hinshaw SP. A preliminary study of sleep in adolescents with bipolar disorder, ADHD, and non-patient controls.-Bipolar Disord 2011: 13: 425-432. 2011 The Authors.-Journal compilation 2011 John Wiley & Sons A/S. Objectives:- To compare the sleep of adolescents with bipolar disorder (BD) to groups of adolescents with attention-deficit hyperactivity disorder-combined type (ADHD-C) and those without psychopathology. Methods:- A sample of 13 adolescents diagnosed with BD who were not in the midst of a mood episode, 14 adolescents with ADHD-C, and 21 healthy controls, all between the ages of 11 and 17 years served as participants. They were psychiatrically evaluated using a structured diagnostic interview and completed four nights of in-home sleep monitoring using actigraph...

2011-01-01

451

A novel method of single step hydrophobic interaction chromatography for the purification of phycocyanin from Phormidium fragile and its characterization for antioxidant property  

British Library Electronic Table of Contents (United Kingdom)

Phycocyanin - a major phycobiliprotein constitutively produced by many cyanobacteria hold several promising applications in diagnostics, biomedical research, and therapeutics. This paper discusses a novel rapid method for the purification of cyanobacterial phycocyanin (C-PC) from Phormidium fragile using hydrophobic interaction chromatography. The protein was extracted and concentrated by grinding under liquid nitrogen and ammonium sulfate fractionation. C-PC was purified by single step hydrophobic interaction chromatography. Purified phycocyanin showed absorbance maximum (lmax) at 624nm. The criterion of purity (R) achieved was 4.52. Phycocyanin to phycoerythrin and phycocyanin to allophycocyanin purity ratio were 3.85 and 7.49, respectively. The purified protein showed a pI of 5.2 and ha...

2008-01-01

452

A novel gamma scanning system for on-line diagnostic inspection of industrial process columns  

International Nuclear Information System (INIS)

A computerised gamma scanning facilities for on-line investigation of industrial process columns and vessels has been developed by the Malaysian Nuclear Agency (Nuclear Malaysia). The technology, based on the principle of gamma-ray absorption, has been successfully applied for real-time troubleshooting, process investigation and predictive maintenance of a number of distillation columns and process vessels in petroleum refineries, gas processing plants and chemical plants in the country and the surrounding region. This paper outlines basic characteristics of the system and describes the inspection procedures, and in addition, presents a number of case studies. The case studies are purposely chosen to illustrate the versatility of the technology, and furthermore to demonstrate the economic benefits which can be realised from the application of this technology. (Author)

453

A comparison of patient doses in lumbar spine radiography from various X-ray units in Poland  

Energy Technology Data Exchange (ETDEWEB)

A number of diagnostic X-ray units in Poland were subjected to analysis. The air kerma on X-ray tables was measured for the X-ray parameters used routinely during lumbo-sacral spine radiography of standard adult patient. Measurements of air kerma were performed using TLD made of lithium-fluoride. The doses received by patients in different X-ray departments can differ more than two orders of magnitude (from 0.42 mGy up to 72.11 mGy), for the same X-ray examination. The dose can be significantly reduced if fluorescent screens made from components of rare earth are used. (author). 10 refs, 1 fig., 2 tabs.

1995-12-31

454

A beam funnelling demonstration: Experiment and simulation  

Energy Technology Data Exchange (ETDEWEB)

Accelerator concepts for heavy-ion fusion require small emittance, high-current beams. Such applications could include funnels in which high-current, like-charged particle beams are interlaced to double beam current while retaining small emittances. The first experimental demonstration confirming the beam dynamics of the funnel principle was recently completed at Los Alamos National Laboratory. A single-leg prototype 5-MeV, H{sup {minus}} funnel was successfully tested. This single-beam demonstration explored physics issues of a two-beam funnel. It contained elements for emittance control, position control, and rf deflection, as well as diagnostics for measurement of beam intensity, position and angle centroids, energy and phase centroids, and transverse and longitudinal phase-space distributions. Results of the experiment will be presented along with comparisons to simulations. 7 refs., 5 figs.

1990-01-01

455

'11-th International Conference - School on Plasma Physics and Controlled Fusion and 2-nd International Workshop on the Role of Electric Fields in Plasma Confinement in Stellarators and Tokamaks'. Book of abstracts  

International Nuclear Information System (INIS)

About 210 abstracts by Ukrainian and foreign authors submitted to the 11-th International Conference on Plasma Physics and Controlled Fusion and 2-nd Alushta International Workshop on the Role of Electric Fields in Plasma Confinement in Stellarators and Tokamaks have been considered by Conference Program Committee members. All the abstracts have been divided into 9 groups: Magnetic confinement systems (stellarators, tokamaks, alternative conceptions); plasma heating and current drive; ITER and fusion reactor aspects; basic plasma physics; space plasma; plasma dynamics and plasma-wall interaction; plasma electronics; low temperature plasma and plasma technologies; plasma diagnostics.

2006-09-11

456

Use of sting-response techniques for simulate diagnostics in human esophagus; Uso de tecnicas estimulo-respuesta para simular diagnosticos en esofago humano  

Energy Technology Data Exchange (ETDEWEB)

In this work a study of simulation of the gamma graphic studies that are carried out in human esophagus in the Dept. of Nuclear Medicine of the 'Celestino Hernandez Robau Hospital of Santa Clara is presented. For the investigation tubular reactors were used and sting-response techniques with radioactive tracer of Technetium 99 metastable to a concentration of 1 mCi and several flows were applied. The distribution curves of residences times were obtained, those that respond to an equation of the type: Y = A + B exp (- exp((x-C)/D)) - ((x-C/D)+1). They were also carried out, optimizations studies of the doses of the radioactive to give to the patients from 1 mCi (that is the one used in studies) up to 0,5 mCi, and the influences on the obtained distributions of residence time were analyzed. It was confirmed the possibility to lower the doses with clear information of the signal. It was also carried out a simulation of the attenuation of the radiations that takes place in the ...

2003-07-01

457

Use of a convolution/superposition-based treatment planning system for dose calculations in the kilovoltage energy range  

International Nuclear Information System (INIS)

A number of procedures in diagnostic radiology and cardiology make use of long exposures to x-rays from fluoroscopy units. Although numerous studies have been performed to measure or calculate skin dose from these procedures, there have only been a handful of studies to determine the dose to the other organs. This thesis was focused on devising a method to calculate the absorbed dose to underlying tissues and organs. The work was performed in several stages. First, a commercial convolution/superposition-based treatment planning system used in radiation oncology was modified and complemented to make it usable with the low energies of x-rays used in diagnostic radiology. This required generation of energy deposition kernels in the kilovoltage energy range. The kernels were generated using the EGS4 Monte Carlo system of codes and added to the treatment planning system. The treatment planning system was then evaluated for its accuracy of ...

2001-03-01

458

Transition armature technology. Progress report No. 2, August 1--September 30, 1991  

Energy Technology Data Exchange (ETDEWEB)

This second report covers the period August 1 to September 30, 1991. During this period we modified our approach to Task 1 (Hybrid Armature study) with the addition of a numerical simulation of the steady state plasma brush length with a 1-D, four-phase equation of state code. A test fixture was designed and fabrication begun on a plasma brush test fixture for hybrid studies. It will be powered by a 140 kJ, 1 MA capacitor bank on loan to the project. Diagnostic data collection with 20 channels of digitizers and data reduction with a microvax were also arranged. Sliding friction of a solid armature was simulated and found to form a vapor layer at velocities below 2 km/s. The simulations indicated that higher interface pressure results in vapor boundary layer formation at lower velocity. If there is also a minimum interface pressure required to commutate high currents, then an optimum interface pressure will probably result. Plans for a launcher test bed were begun ...

1991-12-31

459

The clinical significance of Fuji computed radiography on lateral chest radiogram  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to clarify the benefits of digital lateral chest radiogram. In the basic study, the modulation transfer factor (MTF) and the wiener spectra (WS) of conventional screen film (CSF) and Fuji computed radiography (FCR) were measured. The visibility of the simulated nodules on FCR using 3 human bodies was subjectively compared with that on CSF by 13 observers. In the clinical study, the visibility of the normal structures on FCR was subjectively compared with that on CSF using 50 lateral chest radiograms by 10 observers. The diagnostic performance to detect pulmonary nodules on FCR was also compared with that on CSF using each 30 positive and negative cases by 8 observers. In the basic study, the MTF of FCR was superior to that of CSF, and the WS of FCR displayed in half size was superior to that of CSF. In all exposure conditions, the visibility of the nodules on FCR in the pulmonary apex was inferior to that on CSF, while FCR was superior ...

1995-02-01

460

The clinical significance of Fuji computed radiography on lateral chest radiogram  

International Nuclear Information System (INIS)

The purpose of this study was to clarify the benefits of digital lateral chest radiogram. In the basic study, the modulation transfer factor (MTF) and the wiener spectra (WS) of conventional screen film (CSF) and Fuji computed radiography (FCR) were measured. The visibility of the simulated nodules on FCR using 3 human bodies was subjectively compared with that on CSF by 13 observers. In the clinical study, the visibility of the normal structures on FCR was subjectively compared with that on CSF using 50 lateral chest radiograms by 10 observers. The diagnostic performance to detect pulmonary nodules on FCR was also compared with that on CSF using each 30 positive and negative cases by 8 observers. In the basic study, the MTF of FCR was superior to that of CSF, and the WS of FCR displayed in half size was superior to that of CSF. In all exposure conditions, the visibility of the nodules on FCR in the pulmonary apex was inferior to that on CSF, while FCR was superior ...

1995-01-01

461

Primary spinal epidural extraosseous Ewing's sarcoma: Report of five cases and literature review  

International Nuclear Information System (INIS)

Ewing's sarcoma is the most common malignant bone tumour occurring in children and adolescents and exists in two different clinico pathological entities: osseous Ewing's sarcoma (OES) and extraosseous Ewing's sarcoma (EES). Five cases of primary epidural EES are described, which presented with non-specific symptoms leading to a long diagnostic delay. The median age at diagnosis was 22 years (range 13-36 years). The median diagnostic delay was 3 months. All patients had one or more neurological deficits. All underwent surgical exploration with a laminectomy and partial resection followed by adjuvant radiotherapy to a dose of 46-50 Gy and chemotherapy with VAC (vincristine, adriamycin and cyclophosphamide) alternating with ICE (ifosphamide, cisplatin and etoposide) for at least six cycles. The mean follow-up period is 21.2 months (range 11-32 months). Four of the five patients achieved a complete remission and are disease free at the time of ...

2001-08-01

462

Preoperative staging of rectal carcinoma with combined sonography and pelvic computed tomography  

International Nuclear Information System (INIS)

The accurate staging of rectal carcinoma is very important for treatment planning. The histological data obtained from surgical specimens of 22 patients with rectal carcinoma were compared with pre-and postoperative endorectal US findings and with preoperative CT results. According to an adapted version of Astler and Coller classification, the different degrees of tumor spread into the rectal wall were represented as follows: stage A: 1 patient; stage B1: 5 patients; stage B2: 6 patients; stage C1: 1 patient; stage C2: 8 patients and stage D: 1 patient. Preoperative staging, based on the overall results of CT and US, was in agreement with histology in 19 of 22 cases. Individual analysis of US and CT results, in comparison with histological data, showed US staging accuracy to be 77.3% (17/22 patients). US accuracy in demonstrating tumor spread into the rectal wall (stages A, B1, C1) was 100% (7/7 patients); US was 70% accurate in lymph node detection (7/10 patients) and 93.3% accurate ...

1991-01-01

463

Osteonecrosis of the hip joint in adults; Die Osteonekrose des Hueftgelenks im Erwachsenenalter  

Energy Technology Data Exchange (ETDEWEB)

Osteonecrosis (ON) of the hip joint remains an unsolved therapeutical problem. Diagnosis of ON of the hip has been improved by the technical progress of imaging modalities and better understanding pathomorphology. Over a long period only plain radiographs have been available. Scintigraphy and computed tomography contributed to differential diagnosis and early detection of bone necrosis. Diagnosis in an early reversible stage is of importance. Understanding of pathophysiology, early diagnosis and therapeutical approach has been significantly improved by MR imaging. Using the ARCO system all imaging modalities and their diagnostic viability are described in the five ARCO stages. At the end a diagnostic algorithm will be proposed. (orig.) [German] Die Osteonekrose des Hueftgelenks (ON) stellt noch immer ein nicht geloestes therapeutisches Problem dar. Die diagnostischen Moeglichkeiten bei der ON wurden in den letzten Jahren durch technische ...

2002-06-01

464

Lung perfusion scintigraphy in the diagnosis of peripheral pulmonary stenosis in patients after repair of Fallot tetralogy  

International Nuclear Information System (INIS)

The frequency of peripheral pulmonary artery stenosis in patients after surgical repair of tetralogy of Fallot (TOF) ranges from 20 to 40%. This can be either primary or secondary to the surgical intervention. The influence of resulting lung perfusion alterations on the life quality of patients is difficult to predict. The aim of this study was to compare the utility of the diagnostic procedures in this group of patients, with particular focus on lung perfusion scintigraphy. This study comprised 104 patients who underwent repair of TOF at ages from 5 months to 25 years. The patients have been followed up for from 4.2 to 25 years. On the basis of chest X-ray peripheral pulmonary artery stenosis was suspected in 11 patients, in 12 on the basis of echocardiography examination. Lung perfusion scintigraphy has been performed on 87 patients. The disturbances in lung perfusion (mostly in the left lung) were show by means of lung perfusion scintigraphy in 43 (49%) of ...

465

Integrated Numerical Experiments (INEX) and the Free-Electron Laser Physical Process Code (FELPPC)  

International Nuclear Information System (INIS)

The strong coupling of subsystem elements, such as the accelerator, wiggler, and optics, greatly complicates the understanding and design of a free electron laser (FEL), even at the conceptual level. To address the strong coupling character of the FEL the concept of an Integrated Numerical Experiment (INEX) was proposed. Unique features of the INEX approach are consistency and numerical equivalence of experimental diagnostics. The equivalent numerical diagnostics mitigates the major problem of misinterpretation that often occurs when theoretical and experimental data are compared. The INEX approach has been applied to a large number of accelerator and FEL experiments. Overall, the agreement between INEX and the experiments is very good. Despite the success of INEX, the approach is difficult to apply to trade-off and initial design studies because of the significant manpower and computational requirements. On the other hand, INEX provides a base ...

1990-07-01

466

Infrarenal abdominal aortic aneurysm. Endovascular repair with stent grafts; Infrarenales Bauchaortenaneurysma. Endovaskulaere Stent-Graft-Therapie  

Energy Technology Data Exchange (ETDEWEB)

As an alternative to surgery, endovascular therapy with stent grafts has become the second main treatment option for infrarenal abdominal aortic aneurysms. Unlike surgery, endovascular treatment with stent grafts is also applicable in patients unfit for open repair. Despite current improvements in endovascular repair devices, significant anatomic barriers still exclude this technique for a large number of patients. Computed tomography, magnetic resonance imaging, and ultrasound are essential for diagnostics, preintervention planning, and postintervention follow-up of abdominal aneurysms treated with stent grafts. This review covers etiology, pathology, and diagnostic aspects. Materials and methods for endovascular treatment of abdominal aortic aneurysms are presented in detail, and clinical results and complications are discussed. (orig.) [German] Die endovaskulaere Therapie des infrarenalen Bauchaortenaneurysmas hat sich als Alternative zur ...

2008-09-15

467

Influence of contrast-enhanced CT and MRI with or without SPIO particles on therapy and therapy costs for patients with focal liver disease  

International Nuclear Information System (INIS)

Purpose: Evaluation of the diagnostic efficacy and cost-benefit of contrast enhanced CT (CT) and MRI pre- and post-SPIO-particles in focal hepatic disease with consideration of therapeutic outcome. Results: In 34/52 (65.4%) of the cases the correct diagnosis was primarily stated by CT (sensitivity [se.] 85.2%, specificity [sp.] 44.0%). In additional 10/52 of the cases unenhanced MRI (se. 91.4%, sp. 75.0%) enabled correct diagnoses, and in another 6 cases the diagnosis was established only by SPIO-MRI (se. 100%, sp. 86.7%). Considering the possible therapeutic recommendation arising from each modality, CT would have induced needless therapy costs of 191,042 DM, unenhanced MRI of 171,035 DM, and SPIO-MRI of 7,311 DM. In comparison to the real therapy costs of 221,873 DM, this would have corresponded to an unnecessary increase of therapy costs of 86.1%, 77.1%, and 3.3%, respectively. In two cases (91 hemangioma, 1 regenerative nodule) all modalities failed, causing ...

2000-03-01

468

Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart  

Energy Technology Data Exchange (ETDEWEB)

The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A{sub 1}) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs{sub eff}). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A{sub 2}). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was applied. The data of all groups were evaluated by a regression analysis. The image ...

2003-12-01

469

Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart  

International Nuclear Information System (INIS)

The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A_1) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs_e_f_f). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A_2). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was applied. The data of all groups were evaluated by a regression analysis. The image quality was ...

2003-12-01

470

Implementation strategies and tools for condition based monitoring at nuclear power plants  

International Nuclear Information System (INIS)

There is now an acute need to optimize maintenance to improve both reliability and competitiveness of nuclear power plant operation. There is an increasing tendency to move from the preventive (time based) maintenance concept to one dependent on plant and component conditions. In this context, various on-line and off-line condition monitoring and diagnostics, nondestructive inspection techniques and surveillance are used. Component selection for condition based maintenance, parameter selection for monitoring condition, evaluation of condition monitoring results are issues influencing the effectiveness of condition based maintenance. All these selections of components and parameters to be monitored, monitoring and diagnostics techniques to be used, acceptance criteria and trending for condition evaluation, and the economic aspect of predictive maintenance and condition monitoring should be incorporated into an integrated, effective condition ...

2009-01-01

471

High-resolution brain SPECT imaging in attention deficit hyperactivity disorder children without comorbidity: quantitative analysis using statistical parametric mapping(SPM)  

Energy Technology Data Exchange (ETDEWEB)

We examined the abnormalities of regional cerebral blood flow(rCBF) in children with attention deficit hyperactivity disorder(ADHD) without comorbidity using statistical parametric mapping(SPM) method. We used the patients with not compatible to DSM-IV diagnostic criteria of ADHD and normal rCBF pattern in visual analysis as normal control children. Tc-99m ECD brain SPECT was performed on 75 patients (M:F=64:11, 10.0{+-}2.5y) with the DSM-IV diagnostic criteria of ADHD and 13 normal control children (M:F=9:4, 10.3{+-}4.1y). Using SPM method, we compared patient group's SPECT images with those of 13 control subjects and measured the extent of the area with significant hypoperfusion(p<0.01) in predefined 34 cerebral regions. Only on area of left temporal lobe showed significant hypoperfusion in ADHD patients without comorbidity (n=75) compared with control subjects(n=13). (n=75, p<0.01, extent threshold=16). rCBF of left ...

2002-07-01

472

Gamma and X-ray shielding compositions utilizing bauxite - Red Mud regional research laboratory (CSIR), Bhopal, India  

International Nuclear Information System (INIS)

Available in abstract form only. Full text of publication follows: The application spectrum of X-ray and Gamma radiation is increasing exponentially in the area of diagnostic, nuclear medicine, food preservation, nuclear power plants and strategic utilities. To prevent the harmful effects of these radiations, shielding materials based on lead metal and its compounds are being used historically, which are toxic in nature. To protect environment it has become necessary to develop non-toxic lead free shielding materials. The use of titanium metal and its compounds as synthetic rock i.e. SYNROC are reported to be very effective non-toxic shielding materials for various applications. Red mud waste generated in aluminum producing industries possesses a unique mineralogical compositions containing fairly high quantity of titanium oxide and iron oxide useful for making non toxic shielding compositions and therefore red mud has been utilized for the first time in the world ...

2007-09-02

473

Feasibility study of computed tomography colonography using limited bowel preparation at normal and low-dose levels study  

Energy Technology Data Exchange (ETDEWEB)

The purpose was to evaluate low-dose CT colonography without cathartic cleansing in terms of image quality, polyp visualization and patient acceptance. Sixty-one patients scheduled for colonoscopy started a low-fiber diet, lactulose and amidotrizoic-acid for fecal tagging 2 days prior to the CT scan (standard dose, 5.8-8.2 mSv). The original raw data of 51 patients were modified and reconstructed at simulated 2.3 and 0.7 mSv levels. Two observers evaluated the standard dose scan regarding image quality and polyps. A third evaluated the presence of polyps at all three mSv levels in a blinded prospective way. All observers were blinded to the reference standard: colonoscopy. At three times patients were given questionnaires relating to their experiences and preference. Image quality was sufficient in all patients, but significantly lower in the cecum, sigmoid and rectum. The two observers correctly identified respectively 10/15 (67%) and 9/15 (60%) polyps {>=}10 mm, with 5 and 8 ...

2007-12-15

474

Fault detection and diagnosis of a gearbox in marine propulsion systems using bispectrum analysis and artificial neural networks  

Science.gov (United States)

A marine propulsion system is a very complicated system composed of many mechanical components. As a result, the vibration signal of a gearbox in the system is strongly coupled with the vibration signatures of other components including a diesel engine and main shaft. It is therefore imperative to assess the coupling effect on diagnostic reliability in the process of gear fault diagnosis. For this reason, a fault detection and diagnosis method based on bispectrum analysis and artificial neural networks (ANNs) was proposed for the gearbox with consideration given to the impact of the other components in marine propulsion systems. To monitor the gear conditions, the bispectrum analysis was first employed to detect gear faults. The amplitude-frequency plots containing gear characteristic signals were then attained based on the bispectrum technique, which could be regarded as an index actualizing forepart gear faults diagnosis. Both the back propagation neural network ...

2011-03-01

475

Dosimetry measurements of x-ray and neutron radiation levels near the shuttle and end beam dump at the advanced test accelerator: Beam Research Program  

International Nuclear Information System (INIS)

Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and potentially damaging to instrumentation that may be used for diagnostics. To provide shielding for minimizing the risk of ...

476

Computed tomography in AIDS-related thoracic diseases; Computertomographie AIDS-assoziierter Thoraxerkrankungen  

Energy Technology Data Exchange (ETDEWEB)

Pulmonary infections and tumors are a major cause of death in patients with AIDS. The combination of clinical, radiological, laboratory, and pathohistological data helps to narrow the spectrum of differential diagnoses or even allows a specific diagnosis in many patients. Nevertheless, an accurate diagnosis should be obtained as soon as possible during the clinical course of the illness to initiate treatment in time. Computed tomography (CT) has proven to provide promising results in the diagnosis of AIDS-related throacic diseases. The aim of this paper was to demonstrate the diagnostic capacities of CT in the context of particular AIDS-related thoracic pathologies. Additional information on the spectrum of pathological agents and on differential diagnostic signs is summarized. (orig.) [Deutsch] Pulmonale Infektionen und Tumore sind eine wesentliche Todesursache bei Patienten, die am erworbenen Immunmangelsyndrom AIDS leiden. In den meisten ...

1996-07-01

477

Clinical use of lipiodol in hepatic arteriography  

Energy Technology Data Exchange (ETDEWEB)

Lipiodol, lipid soluble contrast media, was applied to 59 patients, who was clinically suspected to have hepatic tumor, in the Department of Diagnostic Radiology, Seoul National University Hospital. The results of the clinical use of Lipiodol were as follows: 1. The clinical diagnosis was hepatocellular carcinoma (HCC) in 50 cases, cavernous hemangioma in 4 cases, metastasis in one case and others in 4 cases. 2. After hepatic arteriography, Lipiodol only was injected in 28 cases, mixture of Lipiodol and Mitomycin was injected in 22 cases and transcatheter arterial embolization was performed additionally after injection of Lipiodol and Mitomycin in 9 cases. 3. Among the 50 cases of HCC, Lipiodol was accumulated in the lesion in 49 cases. However, similar accumulation of Lipiodol occured in a metastatic cancer and cavernous hemangiomas. 4. Plain radiographic patterns of Lipiodol accumulation could be divided into fine granular type, nodular type and linear or ...

1986-08-15

478

CT colonography: optimisation, diagnostic performance and patient acceptability of reduced-laxative regimens using barium-based faecal tagging  

Energy Technology Data Exchange (ETDEWEB)

To establish the optimum barium-based reduced-laxative tagging regimen prior to CT colonography (CTC). Ninety-five subjects underwent reduced-laxative (13 g senna/18 g magnesium citrate) CTC prior to same-day colonoscopy and were randomised to one of four tagging regimens using 20 ml 40%w/v barium sulphate: regimen A: four doses, B: three doses, C: three doses plus 220 ml 2.1% barium sulphate, or D: three doses plus 15 ml diatriazoate megluamine. Patient experience was assessed immediately after CTC and 1 week later. Two radiologists graded residual stool (1: none/scattered to 4: >50% circumference) and tagging efficacy for stool (1: untagged to 5: 100% tagged) and fluid (1: untagged, 2: layered, 3: tagged), noting the HU of tagged fluid. Preparation was good (76-94% segments graded 1), although best for regimen D (P = 0.02). Across all regimens, stool tagging quality was high (mean 3.7-4.5) and not significantly different among regimens. The HU of layered tagged fluid was ...

2008-01-15

479

CT colonography with minimal bowel preparation: evaluation of tagging quality, patient acceptance and diagnostic accuracy in two iodine-based preparation schemes  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study was to compare a 1-day with a 2-day iodine bowel preparation for CT colonography in a positive faecal occult blood test (FOBT) screening population. One hundred consecutive patients underwent CT colonography and colonoscopy with segmental unblinding. The first 50 patients (group 1) ingested 7*50 ml iodinated contrast starting 2 days before CT colonography. The latter 50 patients (group 2) ingested 4*50 ml iodinated contrast starting 1 day before CT colonography. Per colonic segment measurements of residual stool attenuation and homogeneity were performed, and a subjective evaluation of tagging quality (grade 1-5) was done. Independently, two reviewers performed polyp and carcinoma detection. The tagging density was 638 and 618 HU (p = 0.458) and homogeneity 91 and 86 HU for groups 1 and 2, respectively (p = 0.145). The tagging quality was graded 5 (excellent) in 90% of all segments in group 1 and 91% in group 2 (p = 0.749). Mean per-polyp sensitivity for lesions ...

2010-02-15

480

Helical CT of traumatic injuries of the thoracic aorta; Applicazioni della Tomografia Computerizzata spirale nello studio delle lesioni traumatiche dell'aorta toracica  

Energy Technology Data Exchange (ETDEWEB)

Acute thoracic aortic injuries account for up to 10-20% of fatalities in high-speed deceleration road accidents and have an estimated immediate fatality rate of 80-90%. Untreated survivors to acute trauma (10-20%) have a dismal prognosis: 30% of them die within 6 hours, 40-50% die within 24 hours, and 90% within 4 months. It was investigated the diagnostic accuracy of Helical Computed Tomography (Helical CT) in acute traumatic injuries of the thoracic aorta, and the role of this technique in the diagnostic management of trauma patients with a strong suspicion of aortic rupture. It was compared retrospectively the chest Helical CT findings of 256 trauma patients examined June 1995 through August 1999. Chest Helical CT examinations were performed according to trauma score, to associated traumatic lesions and to plain chest radiographic findings. All the examinations were performed with no intravenous contrast agent administration and the pitch 2 ...

2000-09-01

481

Measurement of dose-area product in diagnostic radiology as a method of assessing the radiation exposure. (Results, experience, proposals for improvement, recommendations relating to radiological protection). Report of an expert meeting; Die Messung des Dosisflaechenproduktes in der diagnostischen Radiologie als Methode zur Ermittlung der Strahlenexposition. (Ergebnisse, Erfahrungen, Verbesserungsvorschlaege und Empfehlungen zum Strahlenschutz). Bericht ueber ein Expertentreffen  

Energy Technology Data Exchange (ETDEWEB)

The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product measurement in the dosimetry activities in medical ...

1995-12-31

482

Lymph node staging in cervical carcinoma: Results of high resolution MRT with phased-array coil; Lymphknotenstaging beim Zervixkarzinom: Ergebnisse der hochaufloesenden Magnetresonanztomographie (MRT) mit einer Phased-Array-Koerperspule  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T{sub 2}-weighted turbo-spin-echo (TSE) and T{sub 1}-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm{sup 2}. Lymph nodes with a diameter of {>=}8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes ({>=} 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of 24 cases MR findings were true negative (specificity 92%). Diagnostic accuracy was ...

1997-03-01

483

Evaluation of node involvement in non small cell bronchogenic carcinoma. CT-pathology correlation  

International Nuclear Information System (INIS)

The main purpose of this work is to evaluate the role of CT in identifying other morphological signs of met static lymph node involvement from non small cell bronchogenic carcinoma. This is done to improve N staging, a critical step in this disease. In fact, since diameter is the only criterion used to distinguish normal form abnormal lymph nodes, mediastinal CT only has 80% diagnostic accuracy. 137 patients with known or suspected lung cancer were examined with Helical CT during early and late arterial phases (2 min. delay, 3 mm thickness, 5 mm inter slice gap) to depict node characteristics. Mediastinal lymph nodes, located according to the American Thoracic Society mapping, were considered normal when they were not visible or, if visible, less than 1 cm in diameter and of homogeneous density; lymph nodes over 1 cm in diameter and homogenous density were considered reactive. A lymph node was considered metastatic when, independent of size, the following signs ...

2000-05-01

484

Scintiscanning with aerosols of "9"9Tc"m DTPA in the diagnostic strategy for pneumocystosis in aids patients  

International Nuclear Information System (INIS)

Pulmonary clearance of an aerosol of "9"9Tc"m DTPA was measured in 21 non-smoking AIDS and pneumocystosis patients. The results were compared with those of pulmonary scintiscanning with gallium. All the patients exhibited increased clearance, evidence of a considerable alteration in alveolar permeability. This increase was also observed in patients with normal chest X-rays and normal blood gases. The average clearance in these patients was 6 #+-# 2% min"-"1 as compared with a normal 1.1 #+-# 0.3% min"-"1. Conversely, only four out of eight patients with normal chest X-rays had abnormal gallium scans. Clearance returned to normal after recovery. Measurement of DTPA clearance appears to be a very sensitive indicator for the detection and follow-up of pneumocystosis. However, it is not very specific since it can be increased by tobacco poisoning, drug abuse and the presence of lymphocytic alveolitis. An examination with normal findings can therefore exclude the possibility of ...

1988-08-15

485

Radiation exposure of children in pediatric radiology. Pt. 6. Conversion factors for reconstruction of organ dose in abdominal radiography; Zur Strahlenexposition von Kindern in der paediatrischen Radiologie. T. 6. Konversionsfaktoren zur Rekonstruktion von Organdosen bei Abdomenaufnahmen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: calculation of conversion coefficients for the reconstruction of organ doses from entrance doses for abdomen radiographs of 0, 1, 5, 10, 15, and 30-year-old patients in conventional pediatric radiology for the radiographic settings recommended by the German and European guidelines for quality management in diagnostic radiology. Materials und method: using the commercially available personal computer program PCXMC developed by the Finnish Center for Radiation and Nuclear Safety (Saeteilyturvakeskus STUK), conversion coefficients for conventional abdomen radiographs were calculated performing Monte Carlo simulations in mathematical hermaphrodite phantom models describing patients of different ages. The possible clinical variation of beam collimation was taken into consideration by defining optimal and suboptimal radiation fields on the phantoms' surfaces. Results: conversion coefficients for the reconstruction of organ does in about 40 organs and ...

2009-10-15

486

Optimisation of imaging technique used in direct digital radiography  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion from being reached. The fact that all images were of diagnostic quality, however, suggested that the use of the anti-scatter ...

2006-09-15

487

Optimisation of imaging technique used in direct digital radiography  

International Nuclear Information System (INIS)

The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion from being reached. The fact that all images were of diagnostic quality, however, suggested that the use of the anti-scatter ...

2006-09-01

488

Magnetic resonance imaging in multiple sclerosis. Imagerie nouvelle par resonance magnetique nucleaire au cours de la sclerose en plaques  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) has rapidly attained a major position among the examinations used in the diagnostic approach of multiple sclerosis because it is highly sensitive in demonstrating lesions. However, these lesional images may have several meanings, and there is the problem of distinguishing between oedema, which is said to reflect recent lesions, and gliosis which is thought to betray old lesions. The intrinsic MRI parameters studied (i.e. relaxation times) are unable to make this distinction, whereas it is provided by paramagnetic contrast media such as gadolinium. There is no correlation between the changes observed at MRI and the severity of the disease. Another problem is the accuracy of lesion localization, since visualization is predominantly macroscopic. This raises several questions about the demonstration of correlations between clinical signs and site of the lesion(s). At the moment, several teams of neuroradiologists are trying to find the ...

1991-09-15

489

Instrumentation and Controls Division progress report, September 1, 1980-July 1, 1982  

Energy Technology Data Exchange (ETDEWEB)

Activities are reported by the Reactor Systems Section, Research Instrument Section, and the Measurement and Controls Engineering Section. Reactor system activities include dynamic analysis, survillanc and diagnostic methods, design and evaluation, detectors, facilities support, process instrumentation development, and special assignments. Activities in the Research Instrument Section include the Navy-ORNL RADIAC development program, advanced ..gamma.. and x ray detector systems, neutron detection and subcriticality measurements, circuit development, position-sensitive detectors, stand-alone computers, environmental monitoring-detectors and systems, plant security, engineering support for fusion energy division, engineering support for accelerator physics, and communications: radio, closed-circuit tv, and computer. Activities in the Measurement and Controls Engineering Section include the AVLIS program; gas centrifuge enrichment technology support; Advanced ...

1982-12-01

490

Can magnetospheric electron temperature be inferred from whistler dispersion measurements  

International Nuclear Information System (INIS)

An approximate expression for whistler-mode group velocity is obtained, taking into account the effects of electron temperature and anisotropy, density and ion effects, effects of oblique propagation and a non-dipolarity of the dayside magnetospheric magnetic field. This expression is applied to the propagation of whistlers between one hemisphere and the other. It is pointed out that at frequencies close to the upper cut-off of whistler spectra, perturbations to whistler group delay times due to temperature effects can be of the same order of magnitude as, or even higher than, the corresponding perturbations due to finite electron density and ion effects. A method of magnetospheric electron temperature diagnostics is proposed and applied to two whistlers recorded at Halley (L = 4.3). It is pointed out that the values of temperature obtained from the analysis of whistler spectra depend on the choice of model of electron density and temperature distribution in the ...

491

Body dose conversion factors for computerized tomography  

International Nuclear Information System (INIS)

While there have been many experimental and calculational investigations on absorbed dose distribution in the patient resulting from conventional X-ray procedures, such data for computerized tomography (CT) are still sparse. As this diagnostic procedure has shown a rapid increase in application during recent years, we have determined absorbed dose to body organs in a human phantom resulting from CT examinations. The exposure model consists of the heterogeneous MIRD-5 phantom and a suitable Monte-Carlo method to calculate absorbed dose to organs of interest. The exposure conditions are specified according to the exposure specifications of a CT-scanner currently in use. The calculations cover the range of body tissues of interest in terms of organ absorbed doses as well as a risk weighted absorbed dose. A detailed example showing the calculation of red bone marrow dose is given and a somatic effective dose equivalent Hsub(ES) is calculated for different conventional ...

1980-10-31

492

Assessment of asymptomatic liver fibrosis in alcoholic patients using fibroscan: prospective comparison with seven non-invasive laboratory tests  

British Library Electronic Table of Contents (United Kingdom)

Summary Background Systematic screening for liver fibrosis in heavy-drinking patients is a challenge. Aims To assess Fibroscan for non-invasive diagnosis of asymptomatic liver fibrosis in alcohol abuse patients, to determine diagnostic liver stiffness cut-off values and to compare performance of Fibroscan with seven non-invasive laboratory tests. Methods One hundred and three alcoholic patients were studied. Liver fibrosis was staged by METAVIR system. Fibroscan, Fibrotest, Fibrometer, Hepascore, APRI, PGA, PGAA and hyaluronic acid tests were performed. Liver stiffness cut-offs were determined using receiver-operating characteristic (ROC) curves. Results Liver stiffness was correlated with fibrosis (r = 0.72, P < 0.014), with median at 5.7, 6.3, 8.4, 15 and 47.3 kPa for F0 (n = 8), F1 (n =...

2008-01-01

493

Apoferritin Templated Synthesis of Metal Phosphate Nanoparticle Labels for Electrochemical Immunoassay  

Energy Technology Data Exchange (ETDEWEB)

W have introduced template-synthesized metal phosphate nanoparticle labels for electrochemical immunoassay. Such use of an apoferritin template offers a simple and convenient route to prepare metallic nanoparticle labels for electrochemical immunoassays and avoid the complicated and time-consuming nanoparticle synthesis process (QD synthesis). Releasing metal ions from metal phosphate in an acetate buffer (pH 4.6) eliminates the harsh condition in the traditional metallic nanoparticle dissolution (e.g., strong acid dissolution of QDs and gold nanoparticles). This method is ultrasensitive and its DL is low to 77fM. The simultaneous detection of multiple protein targets is easily performed by using different metal phosphate nanoparticle labels (cadmium phosphate and lead phosphate). This approach can be extended to prepare multiple metal (such as zinc, lead, cadmium, copper, indium, gold, silver) phosphate nanoparticle labels or hybrid metal (bimetallic or trimetallic with predetermined ...

2006-08-29

494

Analysis of complex systems using neural networks  

Energy Technology Data Exchange (ETDEWEB)

The application of neural networks, alone or in conjunction with other advanced technologies (expert systems, fuzzy logic, and/or genetic algorithms), to some of the problems of complex engineering systems has the potential to enhance the safety, reliability, and operability of these systems. Typically, the measured variables from the systems are analog variables that must be sampled and normalized to expected peak values before they are introduced into neural networks. Often data must be processed to put it into a form more acceptable to the neural network (e.g., a fast Fourier transformation of the time-series data to produce a spectral plot of the data). Specific applications described include: (1) Diagnostics: State of the Plant (2) Hybrid System for Transient Identification, (3) Sensor Validation, (4) Plant-Wide Monitoring, (5) Monitoring of Performance and Efficiency, and (6) Analysis of Vibrations. Although specific examples described deal with nuclear power ...

1992-12-31