Comparison of LaBr_3:Ce and NaI(Tl) Scintillators for Radio-Isotope Identification Devices  

International Nuclear Information System (INIS)

Lanthanum halide (LaBr_3:Ce) scintillators offer significantly better resolution (< 3% at 662 keV) relative to NaI(Tl) and have recently become commercially available in sizes large enough for the handheld, Radio-Isotope Identification Device (RIID) market. Drawbacks to lanthanum halide detectors, however, include internal radioactivity contributing to spectral counts, and a low-energy response which can cause detector resolution to be worse than that of NaI(Tl) below 100 keV. To study the potential of this new material for RIIDs we performed a series of measurements comparing a 1.5 x 1.5-inch LaBr_3:Ce detector with an Exploranium GR-135 RIID, which contains a 1.5 x 2.2-inch NaI(Tl) detector. Measurements were taken for short timeframes, as typifies RIID usage. Measurements included examples of naturally occurring radioactive material (NORM), typically found in cargo, and ...

2005-10-23

3

Photodiode Scintillation Detector for Anti-Coincidence Shielding  

Science.gov (United States)

Photodiode Scintillation Detector for Anticoincidence Shielding An important goal of space research is to understand the physics involved in the activity of ...

5

Development of a small scintillation detector with an optical fiber for fast neutrons  

International Nuclear Information System (INIS)

To investigate the characteristics of a reactor and a neutron generator, a small scintillation detector with an optical fiber with ThO_2 has been developed to measure fast neutrons. However, experimental facilities where "2"3"2Th can be used are limited by regulations, and S/N ratio is low because the background counts of this detector are increase by alpha decay of "2"3"2Th. The purpose of this study is to develop a new optical fiber detector for measuring fast neutrons that does not use nuclear material such as "2"3"2Th. From the measured and calculated results, the new optical fiber detector which uses ZnS(Ag) as a converter material together with a scintillator have the highest detection efficiency among several developed detectors. It is applied for the measurement of reaction rates generated from fast neutrons; furthermore, the ...

2011-02-01

6

Position sensitive detection of individual nuclear particle scintillations using image intensifier tubes  

International Nuclear Information System (INIS)

An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are ...

1996-01-01

7

Measurements and elimination of Cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry  

International Nuclear Information System (INIS)

In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component ...

2007-08-21

8

Bragg curve spectroscopy in a 4? geometry  

Science.gov (United States)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4? geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon.

1991-02-01

9

Bragg curve spectroscopy in a 4. pi. geometry  

Energy Technology Data Exchange (ETDEWEB)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4{pi} geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).

1991-02-01

10

Bragg curve spectroscopy in a 4#pi# geometry  

International Nuclear Information System (INIS)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4#pi# geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).

11

Development of a new #gamma#-ray detector for PEM applications  

International Nuclear Information System (INIS)

The authors are developing a high specificity detector for detecting the increased metabolic rate of breast tumors. Positron emission mammography (PEM) provides a highly efficient, high spatial resolution positron imaging system. PMT plays a very important role in PEM detectors, because most of the systems consist of scintillator arrays coupled with PMT. Our detector is composed of 20 x 20 arrays of 2 mm x 2 mm x 20 mm of Bi_4Ge_3O_1_2 (BGO) scintillators and a novel flat panel position-sensitive PMT (FP-PS-PMT)-Hamamatsu R8400-00-M256. Spatial resolutions of 2.0 mm FWHW and energy resolutions of 23% FWHM are achieved. (authors)

2007-05-01

12

Medical explorations by radioisotopes in Lebanon  

International Nuclear Information System (INIS)

This study mainly concerns medical explorations by radioisotopes. Detectors with medical exams and applications are described. Ionisation chambers, semiconductor detectors and scintillation counters are also presented. Uses of radioisotopes in medicine in vivo and in vitro techniques are explained. Examples of scintiscanning are given like: angiography, nuclear cardiography and thyroid scintiscanning. The importance of the study is to present a panorama of nuclear medicine laboratories -at the time- in hospitals in Lebanon.

13

Segmented focal plane detector for light and heavy ions  

Energy Technology Data Exchange (ETDEWEB)

A segmented focal plane detector for an Enge split-pole spectrograph has been developed for the study of breakup reactions at very low relative energies. It consists of a 61 cm long segmented position-sensitive parallel plate avalanche counter backed by a large Bragg curve detector. A segmented plastic scintillator is mounted behind the anode of the Bragg curve detector and is used for particle identification of low-ionizing particles. The dead space between the two sections of the focal plane detector is 2.5 mm. The intrinsic position resolution of the detector is 1 mm. The intrinsic energy resolution depends on the energy of the incident ion and can be as good as 0.55%. The nuclear charge and mass resolutions are 0.3 e and 0.3 u, respectively. (orig.).

1992-06-15

14

The hunt for ?13 at the Daya Bay nuclear power plant  

International Nuclear Information System (INIS)

The Daya Bay reactor neutrino experiment is located at the Daya Bay nuclear power plant in Shenzhen, China. The experiment deploys eight 'identical' antineutrino detectors to measure antineutrino fluxes from six 2.9 GWth reactor cores in three underground experimental halls at different distances. The target zone of the Daya Bay detector is filled with 20 t 0.1% Gd doped LAB liquid scintillator. The baseline uncorrelated detector uncertainty is ?0.38% using current experimental techniques. Daya Bay can reach a sensitivity of sin22?13<0.01 with baseline uncertainties after 3 years of data taking.

2010-03-30

15

A large surface neutron and photon detector for civil security applications  

Energy Technology Data Exchange (ETDEWEB)

The security of ports and transportation is of utmost importance for the development of economy and the security of a nation. Among the necessary actions to ensure the security of ports and borders, the inspection of containers is one of the most time consuming and expensive procedures. Potential threats are the illegal traffic of radioactive materials that could be employed for the construction of weapons, as uranium and plutonium. New techniques for the inspections of containers should be fast, allow the detection and identification of dangerous materials, and be non-invasive, to reduce costs and delays. We propose to build a large surface photon and neutron detector based on plastic scintillator to identify the presence of fissile or fertile material inside a container. The detector consists of scintillator bars, wrapped in thin foils of reflecting material containing gadolinium for neutron capture ...

2010-05-21

16

A large surface neutron and photon detector for civil security applications  

International Nuclear Information System (INIS)

The security of ports and transportation is of utmost importance for the development of economy and the security of a nation. Among the necessary actions to ensure the security of ports and borders, the inspection of containers is one of the most time consuming and expensive procedures. Potential threats are the illegal traffic of radioactive materials that could be employed for the construction of weapons, as uranium and plutonium. New techniques for the inspections of containers should be fast, allow the detection and identification of dangerous materials, and be non-invasive, to reduce costs and delays. We propose to build a large surface photon and neutron detector based on plastic scintillator to identify the presence of fissile or fertile material inside a container. The detector consists of scintillator bars, wrapped in thin foils of reflecting material containing gadolinium for neutron capture ...

2010-05-11

17

Construction of a open-quotes black neutron detectorclose quotes at the University of Massachusetts-Lowell Accelerator Laboratory  

International Nuclear Information System (INIS)

In many experiments involving fast neutrons generated in nuclear reactions initiated by accelerator produced charged particle beams, it is important to be able to determine accurately the neutron yield from the target. A detector suitable for such applications should have: a constant efficiency over a large energy range; a fast time response; and the ability to discriminate between gamma rays and neutrons. The authors have constructed a open-quotes black neutron detectorclose quotes based on the design of Poenitz that has these characteristics. At the Lowell Van de Graaff accelerator laboratory neutrons are produced via the "7Li(p,n)"7Be reaction using a pulsed proton beam which impinges on metallic lithium targets. The pulsed beam enables the detector to be used in a time-of-flight spectrometer. Use of BC501 liquid scintillator permits neutron-gamma discrimination. The scintillator is viewed by five ...

1992-03-16

18

Energy resolution of scintillation detectors readout with large area avalanche photodiodes and photomultipliers  

International Nuclear Information System (INIS)

The energy resolution of small NaI(Tl), CsI(Tl), BGO, GSO, YAP and LSO crystals has been studied using 16 mm diameter large area avalanche photodiodes (LAAPD) and a 52 mm diameter photomultiplier. The best result of 4.8% for 662 keV #gamma#-rays from a "1"3"7Cs source was obtained with a 9 mm in diameter by 9 mm high CsI(Tl) scintillator coupled to an LAAPD. Measuring the number of primary electron-hole pairs produced in the LAAPD and photoelectrons in the photomultiplier, as well as the noise contribution of the LAAPD, allowed a quantitative discussion of the results. The energy resolutions measured with LAAPDs are comparable to, or significantly better (at certain emission wavelengths) than, those obtained with the photomultiplier. At energies above 100 keV the energy resolution measured with the majority of crystals and the LAAPD was weakly affected by the photodiode noise contribution. The advantages and limitations of LAAPDs in energy spectrometry with ...

1998-06-01

19

Air Shower Events of High-Energy Cosmic Rays Measured at Seoul, South Korea  

Science.gov (United States)

The COsmic ray Research and Education Array (COREA) collaboration has installed an array of six detector stations at two high schools in and near Seoul, Korea for measurement of air-shower events from high-energy cosmic rays. Three stations are installed at each site, where each station consists of four plastic scintillation detectors covering an area of 2m2. In this presentation, we report the currenst status of the COREA project, describing the experimental equipment and measurement of coincident events.

2011-09-01

20

Selection of dimensions of scintillation detectors and of the correction energy with the use of the dual energy method in computerized tomography  

Science.gov (United States)

The article explains the method of selecting the optimum energy for correcting the energy selectivity of tomographic projection and the optimum length of the crystals corresponding to it when the dual energy method in computerized tomography is used. Results of numerical calculations for actual materials and count results are presented.

1986-05-01

21

Nondestructive determination of airborne lead particulates by the radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).

1980-01-01

22

Measurement of the oil consumption of compressors  

International Nuclear Information System (INIS)

This paper describes a method for measuring oil consumption in compressors. The oil is labelled with Zn 65. The consumed radioactive oil is retained in an activated carbon filter and its activity is measured continuously with a plastic scintillator detector. Measuring the oil consumption at a given operating levels takes about 15 minutes. At an oil consumption rate of about 1 g/h the measurement errors are of the order of +- 5%. (orig.).

23

A search for tachyons in cosmic ray showers  

International Nuclear Information System (INIS)

A search has been made of tachyons associated with cosmic ray showers of energies about 10"1"5 eV by searching for any precursor effects observed in plastic scintillator detectors. Detection thresholds well below most other similar experiments have been reached but no statistically significant effects have been found.

24

SCINTILLATION COUNTERS  

Science.gov (United States)

... 89 11 August 195Z SCINTILLATION COUNTERS *Subtask uder Effects of Irradiation, AMRL Project No. ... 89 SCINTILLATION COUNTERS* by ...

1952-08-11

25

Radiation hardness of plastic scintillating fiber against fast neutron and #gamma#-ray irradiation  

International Nuclear Information System (INIS)

In future collider experiments, where a background radiation level is estimated to be very high, e.g. around 10"2 #approx# 10"5 Gy/yr and 10"1"1 #approx# 10"1"4 n/cm"2/yr at SSC, the detectors operating around the collision point in the experiments will encounter a considerable amount of radiation. Therefore, the detectors, especially the calorimeter, are required to be resistive against high radiation levels. From this point of view, it is of great importance to study the effects of radiation damage on the performance of the detectors. The authors report preliminary results of measurements of radiation hardness of the plastic scintillating fiber Kuraray SCSF-81 against irradiation with fast neutrons and "6"0Co #gamma#-rays in the region of the neutron fluence from 1 x 10"1"1 to 5 x 10"1"3 n/cm"2 and the integrated #gamma#-ray dose from 890 to 10"5 Gy, respectively. Deterioration of both intrinsic light ...

1992-10-25

26

The JT-60U 2.45 MeV neutron time-of-flight spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A 2.45 MeV neutron time-of-flight spectrometer was designed and built for measurements of neutron energy spectra from the JT-60U Tokamak. The spectrometer consists of two fast plastic scintillators (50 cm{sup 2} and 1800 cm{sup 2}, thickness: 2 cm) where each detector is located on two constant time-of-flight spheres. The time-of-flight spheres have radius of 1 m which gives a neutron flight length of {approx}164 cm and a time-of-flight of {approx}92 ns for 2.45 MeV source neutrons. The calculated spectrometer efficiency and resolution are 2.8 x 10{sup -2} cm{sup 2} and 105 keV (4.3%), respectively. The energy resolution corresponds to a time resolution of 2.0 ns. The spectrometer will measure neutrons in a vertical line-of-sight, {approx}9 m from the plasma center. For a total neutron emission of 10{sup 16} n/s, the countrate in the first scattering detector, located in the neutron beam, is estimated to {approx}2.5 MHz. ...

1999-11-01

27

Use of the WNR spallation neutron source at LAMPF to determine the absolute efficiency of a neutron scintillation detector  

Energy Technology Data Exchange (ETDEWEB)

Prompt fission neutron spectrum measurements at the University of Massachusetts Lowell 5.5 MV Van de Graaff accelerator laboratory require that the neutron detector efficiency be well known over a neutron energy range of 100 keV to 20 MeV. The efficiency of the detector, has been determined for energies greater than 5.0 MeV using the Weapons Neutron Research (WNR) white neutron source at the Los Alamos Meson Physics Facility (LAMPF) in a pulsed beam, time-of-flight (TOF) experiment. Carbon matched polyethylene and graphite scatterers were used to obtain a hydrogen spectrum. The detector efficiency was determined using the well known H(n,n) scattering cross section. Results are compared to the detector efficiency calculation program SCINFUL available from the Radiation Shielding Information Center at Oak Ridge National Laboratory.

1994-06-01

28

Zinc determination in medicinal powders by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

X-ray fluorescence analysis was used to determine the zinc content of the ''Perilacin'' powder and the ZnO content of the ''Epiderman-pix'' powder. The characteristic Ksub(#alpha#) line of zinc was excited using a "1"4"7Pm/Mo source (10"7 s"-"1) and the molybdenum Ksub(#alpha#) line (17.47 keV). 4 to 5% Zn and 45 to 49% ZnO were determined with a NaI(Tl) scintillation detector. The radiation intensity was found to decrease with particle size. (M.K.).

1977-01-01

29

Precise Measurement of the Neutron Magnetic Form Factor G{sub M}{sup n} in the Few-GeV{sup 2} Region  

Science.gov (United States)

The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q{sup 2}=1.0-4.8 GeV{sup 2} with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.

2009-05-15

30

Precise Measurement of the Neutron Magnetic Form Factor GMn in the Few-GeV2 Region  

International Nuclear Information System (INIS)

The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q2=1.0-4.8 GeV2 with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.

2009-05-15

31

Development of thin foil Faraday collector as a lost alpha particle diagnostic for high yield D-T tokamak fusion plasmas  

Energy Technology Data Exchange (ETDEWEB)

Alpha particle confinement is necessary for ignition of a D-T tokamak fusion plasma and for first wall protection. Due to high radiation backgrounds and temperatures, scintillators and semiconductor detectors may not be used to study alpha particles which are lost to the first wall during the D-T programs on JET and ITER. An alternative method of charged particle spectrometry capable of operation in these harsh environments, is proposed: it consists of thin foils of electrically isolated conductors with the flux of alpha particles determined by the positive current flowing from the foils. 2 refs., 3 figs.

1994-07-01

32

Radon measurements at the FEMP  

Energy Technology Data Exchange (ETDEWEB)

Environmental radon monitoring activities at the DOE Fernald Environmental Management Project (FEMP) have been conducted extensively since the early 1980`s. Monitoring has been conducted at ambient concentration levels (< 1 pCi/L Rn-222), inside buildings, and at significantly elevated levels (hundreds of thousands pCi/L Rn-222) within the K-65 silo that store concentrated radium bearing wastes. The purpose of this paper/presentation is to present and discuss some of the difficulties encountered/solutions (e.g. reliability, detection limits, affects of environmental factors, data transfer, etc.) that have been discovered while taking measurements using both alpha track-etch passive integrating detectors and alpha scintillation real-time detectors. A short summary and conclusion section is provided following each topic presented.

1993-08-01

33

Neutrino cross sections with the MINER?A Experiment  

British Library Electronic Table of Contents (United Kingdom)

MINER?A is a high resolution, fully active detector designed to study neutrino interactions on nuclei in the NuMI beam at Fermi National Accelerator Laboratory. The active volume of the detector consists of 3 tons of plastic scintillator and includes embedded targets of 4He, C, H2O, Fe and Pb. The MINER?A collaboration expects to perform precision, A-dependent neutrino cross section measurements in the 1?10 GeV region, measure the axial form factor, and study nuclear shadowing of F2, quark-hadron duality and coherent pion production, among other topics. MINER?A began data taking in the fall of 2009. This paper describes the MINER?A experiment and provides an overview of the physics objectives along with estimated uncertainties of the measurements and the tentative projected schedule of dat...

2011-01-01

34

Measurement of dose distributions of linear energy transfer in matter irradiated by fast neutrons  

Energy Technology Data Exchange (ETDEWEB)

A detector has been developed and used to measure dose distributions versus linear energy transfer to thin gas targets in spherical geometry from fast neutron irradiation of tissue-equivalent plastic and carbon. The detector is a hemispherical proportional counter with a Cs(T1) scintillator at the center of the hemisphere. The coincidence of the proportional counter signals constrain the measurements to charged particles traversing the radius of the hemisphere. The charged particle energy deposition distributions are directly measured for a known pathlength. The A-150 kerma factor was measured at a neutron energy of 14.8 MeV and is in agreement with tabulated values. The carbon kerma factor measurements are less than the tabulated value at 14.8 MeV. The alpha-particle production in carbon was measured for neutron energies from 14.1 to 14.8 MeV and is compared with existing data.

1990-01-01

35

Enhancement of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 (16N) and Oxygen-19 (19O) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of 19O and 16N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high ambient radiation level even though sensitivity is appreciably good. For ...

2006-11-13

36

The Pamela Cosmic Ray Space Observatory: Detector, Objectives and First Results  

CERN Document Server

PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range (protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antimatter with a precision of the order of $10^{-8}$). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, 15 2006 in a $350\\times 600 km$ orbit with an inclination of 70 degrees. The detector is composed of a series of scintillator counters arranged at the extremities of a permanent magnet spectrometer to provide charge, Time-of-Flight and rigidity information. Lepton/hadron identification is performed by a Silicon-Tungsten calorimeter and a Neutron detector placed at the bottom of the device. An Anticounter system is used offline to reject false triggers ...

2009-01-01

37

Analysis of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 ("1"6N) and Oxygen-19 ("1"90) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of "1"9O and "1"6N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high background even though sensitivity is appreciably good. For ...

2005-11-23

38

Distribution Models for Optical Scintillation Due to ...  

Science.gov (United States)

... Lincoln Laboratory Distribution Models for Optical Scintillation Due to Atmospheric Turbulence RR Parenti RJ Susiela Group 107 ...

2005-12-12

39

Comparative Equatorial Scintillation Morphology--American ...  

Science.gov (United States)

... Accession Number : ADA066094. Title : Comparative Equatorial Scintillation Morphology--American and Pacific Sectors. ...

1978-06-30

40

Photon dosimetry using plastic scintillators in pulsed radiation fields  

Energy Technology Data Exchange (ETDEWEB)

Simulations and experiments have been carried out to explore using a plastic scintillator as a dosimetry probe in the vicinity of a pulsed bremsstrahlung source in the range 4 to 20 MeV. Taking advantage of the tissue-equivalent properties of this detector in conjunction with the use of a fast digital signal processor near real-time dosimetry was shown to be possible. The importance of accounting for a broad energy electron beam in bremsstrahlung production, and photon scattering and build-up, in correctly interpreting dosimetry results at long stand-off distances is highlighted by comparing real world experiments with ideal geometry simulations. Close agreement was found between absorbed energy calculations based upon spectroscopic techniques and calculations based upon signal integration, showing a ratio between 10 MeV absorbed dose to 12 MeV absorbed dose of 0.66 at a distance of 91.4 m from the accelerator. This is compared with an ...

2007-04-01

41

Detection system characteristics using sup 252 Cf ionization chambers  

Energy Technology Data Exchange (ETDEWEB)

Because the number of neutrons and gamma rays and the energy spectrum of particles from spontaneous fission are well characterized for {sup 252}Cf, it can be used as a timed source of fission neutrons and gamma rays. The first such usage incorporated a {sup 252}Cf source into gas scintillators. This paper describes a timed source of neutrons and gamma rays made by depositing {sup 252}Cf on one electrode of a parallel plate ionization chamber that can then be used for determining detection-system characteristics. The emission time of neutrons from spontaneous fission has also been determined by recording the emission time of prompt gamma rays from a {sup 252}Cf source (not incorporated into a detector) adjacent to the surface of a solid or liquid scintillator. This well characterized source of neutrons can thus be used as a randomly pulsed source for a variety of applications. This paper illustrates the use of this type of ...

1990-01-01

42

Study of core collapse neutrino signals and constraints on neutrino masses from a future Galactic Supernova  

CERN Document Server

We study the sensitivity to neutrino masses of a Galactic supernova neutrino signal as could be measured with the detectors presently in operation and with future large volume water \\v{C}erencov and scintillator detectors. The analysis uses the full statistics of neutrino events. The method proposed uses the principles of Bayesian inference reasoning and has shown a remarkably independence of astrophysical assumptions. We show that, after accounting for the uncertainties in the detailed astrophysical description of the neutrino signal and taking into account the effects of neutrino oscillations in the supernova mantle, detectors presently in operation can have enough sensitivity to reveal a neutrino mass (or to set upper limits) at the level of 1 eV. This is sensibly better than present results from tritium $\\beta$-decay experiments, competitive with the most conservative limits from neutrinoless ...

2005-01-01

43

Modeling of Fission Neutrons as a Signature for Detection of Highly Enriched Uranium  

Energy Technology Data Exchange (ETDEWEB)

We present the results of modeling intended to evaluate the feasibility of using neutrons from induced fission in highly enriched uranium (HEU) as a means of detecting clandestine HEU, even when it is embedded in absorbing surroundings, such as commercial cargo. We characterized radiation from induced fission in HEU, which consisted of delayed neutrons at all energies and prompt neutrons at energies above a threshold. We found that for the candidate detector and for the conditions we considered, a distinctive HEU signature should be detectable, given sufficient detector size, and should be robust over a range of cargo content. In the modeled scenario, an intense neutron source was used to induce fissions in a spherical shell of HEU. To absorb, scatter, and moderate the neutrons, we place one layer of simulated cargo between the source and target and an identical layer between the target and detector. The resulting neutrons ...

2004-03-09

44

Launch of the Space experiment PAMELA  

CERN Document Server

PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antimatter with a precision of the order of 10^-8). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, 15, 2006 in a 350*600 km orbit with an inclination of 70 degrees. The detector is composed of a series of scintillator counters arranged at the extremities of a permanent magnet spectrometer to provide charge, Time-of-Flight and rigidity information. Lepton/hadron identification is performed by a Silicon-Tungsten calorimeter and a Neutron detector placed at the bottom of the device. An Anticounter system is used offline to reject false triggers coming from the ...

2007-01-01

45

Beam Test of a Prototype Detector Array for the PoGO Astronomical Hard X-Ray/Soft Gamma-Ray Polarimeter  

CERN Document Server

Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument designed to measure polarization from astrophysical objects in the 30-100 keV range, under development by an international collaboration with members from United States, Japan, Sweden and France. To examine PoGO's capability, a beam test of a simplified prototype detector array was conducted at the Argonne National Laboratory Advanced Photon Source. The detector array consisted of seven plastic scintillators, and was irradiated by polarized photon beams at 60, 73, and 83 keV. The data showed a clear polarization signal, with a measured modulation factor of $0.42 \\pm 0.01$. This was successfully reproduced at the 10% level by the computer simulation package Geant4 after modifications to its ...

2005-01-01

46

Pre-Flight Development of the PoGOLite Pathfinder  

International Nuclear Information System (INIS)

The Polarized Gamma-ray Observer (PoGOLite) is a balloon-borne instrument that will measure gamma-ray polarization in the energy range 25-80 keV from astronomical sources such as pulsars, accretion discs and jets from active galactic nuclei. The two additional parameters provided by such observations, polarization angle and degree, will allow these objects to be studied in a new way, providing information about their emission mechanisms and geometries. The instrument measures azimuthal scattering angles of photons within a close packed array of phoswich detector cells (PDCs) based on coincident detection of Compton scattering and photoelectric absorption. Each PDC comprises three different scintillating components and combines photon detection, active collimation and bottom anticoincidence into one single unit. The three parts are viewed by a photomultiplier tube (PMT) and pulse shape discrimination is used to identify signals from dierent ...

47

The PAMELA space experiment: first year of operation  

Energy Technology Data Exchange (ETDEWEB)

On the 15th of June 2006 the PAMELA experiment, mounted on the Resurs DK1 satellite, was launched from the Baikonur cosmodrome and it has been collecting data since July 2006. PAMELA is a satellite-borne apparatus designed to study charged particles in the cosmic radiation, to investigate the nature of dark matter, measuring the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved, and to search for antinuclei with unprecedented sensitivity. The apparatus comprises a time-of-flight system, a silicon-microstrip magnetic spectrometer, a silicon-tungsten electromagnetic calorimeter, an anticoincidence system, a shower tail catcher scintillator and a neutron detector. The combination of these devices allows charged particle identification over a wide energy range.

2008-05-15

48

Nuclear radiation detectors on II-VI compounds  

International Nuclear Information System (INIS)

Nuclear radiation detectors in integral execution were produced by successive epitaxial growth from vapor phase of Zn Te and Cd Se thin layers onto scintillating Zn Se (Te) crystals. The irradiation of combined Zn Se (Te) - Zn Te - Cd Se detectors by Cu_K_a X-rays leads to the appearance of photoreceiver e.m.f., which tends to saturation with the increase of X-ray radiation dose reaching the value of 0.34-0.40 V at 200 R/min. The short circuit current dependence of irradiation dose power is linear. The matching factor for detectors with Zn Te-Cd Se photoreceivers with different doping levels is 0.68-0.92. The absolute monochromatic sensitivity is 0.32-0.35 m A/m W at a quantum efficiency 0.58-0.61 and a time constant 2 x 10"-"4 s. The calculated dose sensitivity for Zn Se(Te)-Zn Te-Cd Se combined detectors at the irradiation with X-rays having effective energy 8.86 keV gives the ...

1993-10-13

49

HALO - the helium and lead observatory for supernova neutrinos  

Energy Technology Data Exchange (ETDEWEB)

The Helium and Lead Observatory (HALO) is a supernova neutrino detector under development for construction at SNOLAB. It is intended to fulfill a niche as a long term, low cost, high livetime, and low maintenance, dedicated supernova detector. It will be constructed from 80 tonnes of lead, from the decommissioning of the Deep River Cosmic Ray Station, and instrumented with approximately 384 meters of {sup 3}He neutron detectors from the final phase of the SNO experiment. Charged- and Neutral-Current neutrino interactions in lead expel neutrons from the lead nuclei making a burst of detected neutrons the signature for the detection of a supernova. Existing neutrino detectors are mostly of the water Cerenkov and liquid scintillator types, which are primarily sensitive to electron anti-neutrinos via charged-current interactions on the hydrogen nuclei in these materials. By contrast, ...

2008-11-01

50

Boron-Lined Multichamber and Conventional Neutron Proportional Counter Tests  

Energy Technology Data Exchange (ETDEWEB)

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. These technologies are: 1) Boron trifluoride (BF3)-filled proportional ...

2010-09-07

51

Space Radiation Detector with Spherical Geometry  

Science.gov (United States)

A particle detector is provided, the particle detector including a spherical Cherenkov detector, and

2011-01-01

53

Atmospheric Scintillation Effects on Electromagnetic Weapons  

Science.gov (United States)

... 4. TITLE AND SUBTITLE Atmospheric Scintillation Effects on Electromagnetic Weapons 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. ...

2008-12-01

54

Calibration of cylindrical detectors using a simplified theoretical approach  

Energy Technology Data Exchange (ETDEWEB)

The calibration of cylindrical detectors using different types of radioactive sources is a matter of routine. The most accurate method, that of experiment, is limited by several factors when the energy interval is broad, requiring a relatively large number of primary standards, implying considerable investment of money and time. Several other techniques can be used instead, including Monte Carlo simulations and semi-empirical methods. Calculations based on the first technique require good definition of the geometry and materials, including the dead layer and window thickness together with an accurate set of cross-sections. The second technique requires two different types of experimental input, the first being from use of sources emitting cascade {gamma} rays and the second from use of sources emitting isolated {gamma} rays in order to cover the wide energy range and provide coincidence-summing corrections, respectively. Here, we introduce a new theoretical ...

2006-09-15

55

A search for. nu. sub e appearance from stopped. pi. sup + and. mu. sup + decay at LAMPF (Los Alamos Meson Physics Facility)  

Energy Technology Data Exchange (ETDEWEB)

We report on a recent search for {bar {nu}}{sub e} appearance from stopped {pi}{sup +} {yields} {mu}{sup +}{nu}{sub {mu}} and {mu}{sup +} {yields} e{sup +}{nu}{sub e}{bar {nu}}{sub {mu}} decay made by the LAMPF experiment E645. The appearance of {bar {nu}}{sub e} may occur from {bar {nu}}{sub {mu}} {yields} {bar {nu}}{sub e}, {nu}{sub e} {yields} {bar {nu}}{sub eL}, or {nu}{sub {mu}} {yields} {bar {nu}}{sub eL} oscillations. Appearance may also occur from rare {mu}{sup +} {yields} e{sup +}{bar {nu}}{sub e}{nu}{sub {mu}} decay, which is allowed by a multiplicative lepton charge conservation law. The neutrino energies range from E{sub {nu}} = 0 to 52.8MeV. The neutrino detector, which is located 26.1 meters from the neutrino source, consists of a segmented liquid scintillator and proportional drift tube central detector surrounded by both active and passive shielding. The central detector detects {bar ...

1990-01-01

56

Application of BGO scintillators to absolute measurement of neutron capture cross sections between 0.01 eV and 10 eV  

Energy Technology Data Exchange (ETDEWEB)

Applying a total energy absorption {gamma}-ray detector composed of 12 bricks (5x5 cm{sup 2}, 7.5 cm thick) of Bi{sub 4}Ge{sub 3}O{sub 12}(BGO) scintillators, the absolute measurement of capture cross sections for Au and Sb has been made in an energy region between 0.01 eV and 10 eV using the linac time-of-flight method. Incident thermal neutron flux was absolutely determined by using the BGO detection system with a Sm sample. To extend the neutron flux measurement from the thermal neutron region to higher neutron energy, the {sup 10}B(n, {alpha} {gamma}) reaction was applied. Absolute capture yield for the relevant capture sample was obtained by the saturated capture yield at a large resonance of the sample. Gold was selected to investigate the application of the BGO detection system to the absolute measurement of the capture cross sections, since the {sup 197}Au(n, {gamma}){sup 198}Au reaction cross section is a well known standard one. The ...

1997-07-01

57

Status of the WAND (Waste Assay for Nonradioactive Disposal) project as of July 1997  

Energy Technology Data Exchange (ETDEWEB)

The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole system and to perform the data analysis. ...

1998-03-01

58

Radon generation and transport in and around a gold mine tailings dam in South Africa  

Energy Technology Data Exchange (ETDEWEB)

Naturally Occurring Radioactive Material (N.O.R.M.) occurs in most soil and rock, and by mining and mineral processing, some of the radionuclides are significantly enhanced. An in-situ gamma-ray detector called M.E.D.U.S.A., has been used to produce a map of relative activity concentrations in a gold mine tailings dam on the Witwatersrand in South Africa. A CsI(Na) scintillation detector is used in this system. M.E.D.U.S.A. spectra obtained from the survey were analyzed using the Full-Spectrum Analysis (F.S.A.) procedure to compute the {sup 40}K, {sup 238}U and {sup 232}Th activity concentrations. The activity concentrations are used with global positioning data (G.P.S.) to produce the concentration maps. A hyper-pure germanium gamma-ray detector (Hp Ge) was used to measure gamma-rays from the naturally occurring nuclides for soil samples taken at different points on the site to calibrate the ...

2006-07-01

59

A high-sensitivity small animal SPECT system  

International Nuclear Information System (INIS)

Medical imaging using single gamma-ray-emitting radionuclides typically makes use of parallel hole collimators or pinholes in order to achieve good spatial resolution. However, a tradeoff in sensitivity is inherent in the use of a collimator, and modern preclinical single photon emission computed tomography (SPECT) systems detect a very small fraction of emitted gamma rays, often less than 0.1%. A system for small animal SPECT imaging which uses no collimators could potentially achieve very high sensitivity-several tens of percent-with reasonably sized detectors. This would allow two significant improvements in preclinical studies: images could be obtained more rapidly, allowing higher throughput for screening applications, or for dynamic processes to be observed with very good time resolution; and images could be obtained with less radioactive tracer, making possible the in vivo imaging of low-capacity receptor systems, aiding research into new tracer compounds, ...

2009-03-07

60

Use of neutron and gamma ray spectral measurements and calculations to obtain dosimetric information for DT neutrons  

Energy Technology Data Exchange (ETDEWEB)

Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, spectrometry, kerma distributions, coupled multigroup calculations

1983-01-01

61

Use of neutron and gamma ray spectral measurements and calculations to obtain dosimetric information for DT neutrons  

International Nuclear Information System (INIS)

Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, spectrometry, kerma distributions, coupled multigroup calculations.

7871-01-01

62

Pulmonary retention of lead: an experimental study in man  

Energy Technology Data Exchange (ETDEWEB)

This human investigation of lead absorption from the lungs utilized two forms of lead, lead chloride and lead hydroxide; the former was used in picogram amounts and the latter at microgram levels. These two species of lead were selected in an attempt to simulate the range of physicochemical properties found in atmospheric lead (urban air). Aerosols labeled with lead-203 were made of comparable aerodynamic size by using sodium chloride as the deposition-determining aerosol. After brief, mouthpiece exposures, 17 subjects were followed by serial counting with a thoracic array of scintillation detectors and two leg counters. Serial blood samples were also taken. The two exposure groups showed similar total deposition values (23 vs 26%) and the same biological retention halftimes, viz., 22.6 hr. When the retention data were corrected for blood-borne /sup 203/Pb, the biological halftimes for lung lead retention averaged 13.1 and 14.2 hr, ...

1980-01-01

63

Persistence of terbufos and its metabolites in soil and maize  

International Nuclear Information System (INIS)

Degradation of "1"4C terbufos was studied under greenhouse conditions. A mixture of "1"4C labelled compound (2.48 x 10"4 Bq of O-ethyl-1- "1"4C) und unlabelled compound (0.09 g of the granule formulation Counter 10 G) was applied to pots containing 750 g of sandy loam clay Ultisol soil with 4.9% organic matter and a cation exchange capacity of 7.6. Two treatments were established, one where maize (cultivar Cristiani) was grown and the other without plants. The soil and plants were extracted at 0, 4, 8, 16, 32 and 64 days and analyzed by a liquid scintillation counter, gas chromatography-flame photometric detector (GC-FPD) and autoradiography. The total "1"4C compounds extracted on day 64 were 31 #+-# 5.6% of the radioactivity applied in the treatments with plants and 46.1 #+-# 1.1% without plants. From the autoradiography results it can be concluded that all times the compounds identified by this technique were terbufos, terbufos sulphoxide and ...

1996-07-01

64

PET/MRI hybrid imaging: devices and initial results  

International Nuclear Information System (INIS)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial pilot studies with prototype animal PET/MRI ...

2008-06-01

65

Non-Destructive Testing of Bus-Bar Joints Powering LHC Superconducting Magnets, by Using Gamma Sources  

CERN Document Server

The main LHC superconducting magnets (dipoles and quadrupoles) use Rutherford type cables, stabilized electrically and thermally with copper profiles. The portions of cables are connected to each other by a soft soldering technique (Sn96Ag4) with an overlapping length corresponding to one pitch of the superconducting strands. The splice constitutes a "composite" structure with the interchanging layers of Sn96Ag4 and NbTi superconductor, located inside a Cu cage. In order to ensure a high level of reliability (failure probability not exceeding 10-8) for some 10000 connections in the LHC, a non-destructive technique to check the quantity of solder in the joint is foreseen. The technique is based on a gamma ray source (241Am) and the detection is position-sensitive in the transmission mode. Scintillating detectors of gamma rays are used and their accumulated length corresponds to the length of the radioactive source (120 mm). The method can be ...

2004-01-01

66

Neutron capture therapy beam on the LVR-15 reactor  

Energy Technology Data Exchange (ETDEWEB)

Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head phantom was mapped with a small semiconductor ...

1992-01-01

67

Neutron capture therapy beam on the LVR-15 reactor  

International Nuclear Information System (INIS)

Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head phantom was mapped with a small semiconductor ...

1991-10-01

68

NPDGamma: A Measurement of the Parity-Violating Gamma Asymmetry A in n-p Capture  

Energy Technology Data Exchange (ETDEWEB)

The NPDGamma Experiment measures the parity-violating correlation A{sub {Gamma}Y} between neutron spin and photon momentum in the reaction {rvec n} + p {yields} d + {gamma}. Knowledge of A{sub {Gamma}Y} and other parity-violating observables in few-body nuclear systems will provide constraints for a parameterized description of {Delta}S = 0 parity-violating phenomena free from complications of nuclear structure. The NPDGamma experiment uses a polarized cold pulsed neutron beam, a liquid parahydrogen target, and a cylindrical array of 48 CsI(Tl) scintillation detectors operated in current mode to search for the asymmetry. NPDGamma recently completed the first phase of the program to measure A{sub {Gamma}Y} at the Los Alamos Neutron Science Center with the preliminary result A{sub {Gamma}Y} = (-1.2 {+-} 2.1(stat.) {+-} 0.1(sys.)) x 10{sup -7}, reproducing the previous upper limit from a measurement at a reactor facility. We discuss the ...

2010-01-01

69

Measuring the quark contribution to the proton spin through. nu. p yields. nu. p  

Energy Technology Data Exchange (ETDEWEB)

The LSND (Liquid Scintillator Neutrino Detector) experiment will be performed at LAMPF in the next several years. The main goal of the experiment is to search for {nu}{sub {mu}}-{nu}{sub e} oscillations with high sensitivity; however, an increasingly important by-product of this search is to measure {nu}p {yields} {nu}p elastic scattering and determine the strange quark contribution, {Delta}s, to the spin of the proton. With the 800-MeV proton energy of LAMPF, neutrinos are produced from pion decay-in-flight with an average energy of about 150 MeV. This energy is sufficiently high so that the {nu}p {yields} {nu}p cross section is large and is sufficiently low so that the low Q{sup 2} approximation (Q{sup 2} {much lt} m{sub p}{sup 2}) is valid and the cross section can be expressed in a simple form dependent upon {Delta}s as the only unknown. LAMPF with its 1-mA proton intensity is, therefore, an ideal accelerator to perform this measurement. 12 ...

1991-01-01

70

Detection of Second-Layer Corrosion in Aging Aircraft Fuselage  

International Nuclear Information System (INIS)

A Digital X-ray imaging system using Compton backscattering has been developed to obtain a cross-sectional profile and mass loss of corroded lap-splices of aging aircraft from density variation. A slit-type camera was designed to focus on a small scattering volume inside the material, from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the lap-joint is scanned by moving the scattering volume through the thickness direction of the specimen. The mass loss of each layer has been estimated from a Compton backscatter A-scan to obtain the thickness of each layer including the aluminum sheet, the corrosion layer and the sealant. Quantitative information such as location and width of planar corrosion in the lap splices of fuselages is obtained by deconvolution using a nonlinear least-square error minimization method(BFGS method): A simple ...

2006-12-01

71

Detection of Second-Layer Corrosion in Aging Aircraft  

International Nuclear Information System (INIS)

The Compton backscatter technique has been applied to lap-joint in aircraft structure in order to determine mass loss due to exfoliative corrosion of the aluminum alloy sheet skin. The mass loss of each layer has been estimated from Compton backscatter A-scan including the aluminum sheet, the corrosion layer, and the sealant. A Compton backscattering imaging system has been also developed to obtain a cross-sectional profile of corroded lap-splices of aging aircraft using a specially designed slit-type camera. The camera is to focus on a small scattering volume inside the material from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the layered structure is scanned by moving the scattering volume through the thickness direction of the specimen. The theoretical model of the Compton scattering based on Boltzmann transport theory is presented ...

2009-12-01

72

A superconducting solenoidal spectrometer for a balloon-borne experiment  

Energy Technology Data Exchange (ETDEWEB)

The BESS detector is a new type of balloon-borne spectrometer which utilizes various technologies recently developed for collider experiments. The principal scientific objectives include a measurement of cosmic-ray antiproton spectrum, search for anti-nuclei in cosmic radiation, and precise measurements of cosmic-ray primaries. A thin superconducting solenoidal coil produces a uniform magnetic field of 1 T. Cylindrical drift chambers are located inside and outside the coil and perform continuous tracking. The momentum resolution is 0.5% at 1 GeV/c. i.e., the maximum detectable rigidity is 200 GV. Scintillation counter hodoscopes, placed above and below the solenoid, provide timing and dE/dx measurements and trigger generation. The timing resolution is 80 ps/counter. This cylindrical configuration achieves a large geometrical acceptance of 0.35 m{sup 2} sr which is essential to detect rare cosmic-ray particles. In order to cope with high trigger ...

2000-03-21

73

Scintillation Velocity of PSR B0329+54  

Science.gov (United States)

We monitored PSR B0329+54 for one year using the Nanshan 25-m radio telescope, the scintillation velocity V ISS shows evidence of systematic variation with the day of the year. States of interstellar medium (ISM) are discussed.

2011-07-01

75

Scintillation converter screen investigation for real-time neutron radiography  

International Nuclear Information System (INIS)

(1980). United States Panhuise, VE Bull, SR Seydel, JA Univ of Missouri-

1980-11-21

76

Performance optimization of the Packard 2000 CA/LL liquid scintillation counter for "1"4C dating  

International Nuclear Information System (INIS)

The ability of the Packard 2000 CA/LL liquid scintillation counter to reduce background count rates relies on pulse shape/duration analysis in which short duration organic scintillation events are discriminated from longer duration non-quenchable background events. A consequence of this is a loss in the counting efficiency. The results of this investigation indicate that much of the lost efficiency can be regained by sharpening the true #beta#"- pulse widths via the use of different scintillant combinations and by certain counter modifications. (author).

77

Stabilization of measuring channel of reflective gamma thickness gage by light pulses from additional scintillator  

International Nuclear Information System (INIS)

Possibility for using a sodium iodide scintillator as a reference signal source is considered. Experimental data on studying the performance of a gamma thickness gage with an additional scintillator are given. Results of experimental investigations of a thickness gage dummy proved practical expediency of the principle being considered. It is established, in particular, that the device is ready to operate without warm-up with a constant sensitivity, the deviation not exceeding 0.5%, in the ambient temperature range of 15-25 deg C.

78

New Radiation Stable and Long-Lived Plastic Scintillators  

International Nuclear Information System (INIS)

A study of the influence of the concentration of secondary addition, high concentrations of primary dopant, diffusion enhancer and stabilizer on radiation hardness is presented. It is concluded that the diffusion enhancing technique is the most powerful method for improving radiation hardness. A new polystyrene scintillator which contains 2% pT, 0.02% POPOP, 20% diffusion enhancer and 0.02% stabilizer gave 91% of initial light output immediately after 3 Mrad irradiation in air. Data are presented that show that scintillator prepared from commercial polymer is more radiation-hard and has greater light output than scintillator prepared from monomer. It is assumed that this difference is due to different molecular weight distributions. Some protocols for acceleration of aging (yellowing and crazing) are presented. It is shown that one of the main reasons for aging of plastic scintillators is residual ...

1993-11-15

82

[Hadroproduction of charmed and bottom mesons (Fermilab experiment E-653): Progress report, June 13, 1983--June 14, 1984  

Energy Technology Data Exchange (ETDEWEB)

(I)Results are given for photoproduction of the D{sup *} at 103 GeV. Clean signals are seen for the decay D{sup *{+-}} {yields} {pi}{sup {+-}}D{sup 0} with the D{sup 0} decaying into both K{sup {-+}}{pi}{sup {+-}} and K{sup {-+}}{pi}{sup {+-}}{pi}{sup 0}. Analysis of the Dalitz plot for the K{pi}{pi} mode gives branching fractions (BFs) for K{sup {minus}}{rho}{sup +}, K{sup *{minus}}{pi}{sup +}, and {anti K}{sup *0}{pi}{sup 0} final states. The BF for D{sup 0} {yields} K{sup {minus}}{rho}{sup +}, much lower than a previous result, is in approximate agreement with the value expected for an l=1/2 final state. (II)Inelastic and elastic J/{psi} photoproduction on H is investigated at 103 GeV. The inelastic cross section with E{sub {psi}}/E{sub {gamma}} {lt} 0.9 is significantly lower than the corresponding result for muoproduction on Fe targets, but consistent with second-order perturbative QCD calculation. The mean p{sub +} of inelastic events is larger than that of elastic events. ...

1984-12-31

83

Measurement of. beta. decay energies of short-lived neutron-rich atomic nuclei in the mass range 101 less than or equal toA less than or equal to106 and A=109. Messung von Beta-Zellverfallsenergien kurzlebiger, neutronenreicher Atomkerne im Massenbereich 101 less than or equal toA less than or equal to106 und A=109  

Energy Technology Data Exchange (ETDEWEB)

Q/sub ..beta..-values are determined for 18 nuclei (Zr-, Nb-, Mo-, Tc-, Ru- and Rh-nuclides) with mass numbers 101 less than or equal toA less than or equal to106 and A=109 from measurements of beta decay energies which were carried out at the LOHENGRIN mass separator at the Institut Laue-Langevin in Grenoble (France). The given Q/sub ..beta..-values between 2 and 8 MeV show errors of about 1.5% (with the exception of /sup 103/Zr and /sup 105/Nb resp. and /sup 103/Tc for which larger errors result due to statistical resp. systematic reasons): /sup 101/Zr 5500+-70, /sup 101/Nb 4580+-45, /sup 102/Zr 4670+-40, /sup 102/Nb 7230+-70, /sup 103/Zr 6790+-240, /sup 103/ 5740+-70, /sup 103/Mo 3575+-80, /sup 103/Tc 2585+-70, /sup 104/Nb 8250+-130, /sup 104/Mo 2180+-40, /sup 104/Tc 5520+-100, /sup 105/Nb 6570+-150, /sup 105/Mo 4885+-80, /sup 105/Tc 3750+-60, /sup 106/Mo 3515+-45, /sup 106/Tc 6540+-70, /sup 109/Ru 4150+-80, /sup 109/Rh 2550+-50 (all values in keV). For the measurement of beta-gamma ...

1986-10-31

84

Measurement of #beta# decay energies of short-lived neutron-rich atomic nuclei in the mass range 101 #<=# A #<=# 106 and A=109  

International Nuclear Information System (INIS)

Q_#beta#-values are determined for 18 nuclei (Zr-, Nb-, Mo-, Tc-, Ru- and Rh-nuclides) with mass numbers 101 #<=# A #<=# 106 and A=109 from measurements of beta decay energies which were carried out at the LOHENGRIN mass separator at the Institut Laue-Langevin in Grenoble (France). The given Q_#beta#-values between 2 and 8 MeV show errors of about 1.5% (with the exception of "1"0"3Zr and "1"0"5Nb resp. and "1"0"3Tc for which larger errors result due to statistical resp. systematic reasons): "1"0"1Zr 5500#+-#70, "1"0"1Nb 4580#+-#45, "1"0"2Zr 4670#+-#40, "1"0"2Nb 7230#+-#70, "1"0"3Zr 6790#+-#240, "1"0"3 5740#+-#70, "1"0"3Mo 3575#+-#80, "1"0"3Tc 2585#+-#70, "1"0"4Nb 8250#+-#130, "1"0"4Mo 2180#+-#40, "1"0"4Tc 5520#+-#100, "1"0"5Nb 6570#+-#150, "1"0"5Mo 4885#+-#80, "1"0"5Tc 3750#+-#60, "1"0"6Mo 3515#+-#45, "1"0"6Tc 6540#+-#70, "1"0"9Ru 4150#+-#80, "1"0"9Rh 2550#+-#50 (all values in keV). For the measurement of beta-gamma coincidences a #DELTA#E/E-plastic ...

85

Spectrochemical analysis using infrared multichannel detectors  

CERN Document Server

Spectrochemical analysis using infrared multichannel detectors

2007-01-01

86

CZT Detector and HXI Development at CASS/UCSD  

CERN Document Server

CZT Detector and HXI Development at CASS/UCSD

2006-01-01

87

ACT Lectures on Detectors - Trigger and Data Acquisition (5/5)  

CERN Document Server

ACT Lectures on Detectors - Trigger and Data Acquisition (5/5)

2011-01-01

88

Pulmonary retention of lead: an experimental study in man  

Energy Technology Data Exchange (ETDEWEB)

This human investigation of lead absorption from the lungs utilized two forms of lead, lead chloride and lead hydroxide; the former was used in picogram amounts and the latter at microgram levels. These two species of lead were selected in an attempt to simulate the range of physicochemical properties found in atmospheric lead (urban air). Aerosols labeled with lead-203 were made of comparable aerodynamic size (MMAD 0.25 ..mu..m +- 0.1) by using sodium chloride as the deposition-determining aerosol. After brief, mouthpiece exposures, 17 subjects were followed by serial counting with a thoracic array of 12 2-in. scintillation detectors and two 2-in. leg counters, all coupled to single channel analyzers. Serial blood samples were also taken. The two exposure groups showed similar total deposition values (23 vs 26%) and the same biological retention halftimes, viz., 22.6 h. When the retention data were corrected for blood-borne /sup 203/Pb, the ...

1980-04-01

89

Development of a neutron/. gamma. ray radiation monitor  

Energy Technology Data Exchange (ETDEWEB)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/..gamma.. ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time ..gamma.. spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded ..gamma.. spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations using a linearized ...

1983-01-01

90

Development of a neutron/#gamma# ray radiation monitor  

International Nuclear Information System (INIS)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/#gamma# ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time #gamma# spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded #gamma# spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations using a linearized ...

1983-01-01

91

Development of a Neutron/gamma Ray Radiation Monitor.  

Science.gov (United States)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/gamma ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time gamma spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded gamma spectra created by the photopeak-compton edge combination in the plateau portion of the knee response, correcting equations using a linearized approximation ...

1983-01-01

92

Determination of distal dose edge location by measuring right-angled prompt-gamma rays from a 38 MeV proton beam  

International Nuclear Information System (INIS)

In clinical applications, it is very important to accurately determine the range of a proton beam in a patient. Recently, a prototype prompt-gamma scanning system, called a prompt-gamma scanner (PGS), has been constructed at Hanyang University in Korea with the collaboration of the Korean national cancer center (NCC), based on a series of Monte Carlo simulations. The PGS system is composed of a prompt-gamma collimator, a CsI(Tl) scintillation detector, a multi-channel analyzer (MCA), a precision movement system, and an integrated readout system. The prompt-gamma collimator is designed to effectively shield high-energy neutrons from the proton beam passage and subsequent capture gammas. The PGS system can be used to scan the distribution of the prompt gammas in the patient from the proton beam passage. The distribution of the prompt gammas can then be used to determine the proton beam range or the distal dose edge in the patient. In this study, ...

2007-09-21

93

Radiation hardness of plastic scintillating fiber  

International Nuclear Information System (INIS)

We report on measurements of radiation hardness of the plastic scintillating fiber SCSF-81. Fibers were irradiated with "6"0Co #gamma#-rays and fast neutrons up to 105 Gy and up to 5 x 1013 n/cm"2, respectively. Deterioration of the attenuation length of the scintillating fiber was studied. Some significant deterioration was observed at the integrated dose of about 1 x 103 Gy and at the integrated neutron flux (neutron fluence) of about 1 x 1012 n/cm"2 for #gamma#-ray and neutron irradiation, respectively. (author).

94

Measurement of liquid xenon scintillation from heavy ions using a silicon photodiode  

Energy Technology Data Exchange (ETDEWEB)

Scintillation light in liquid xenon excited by 100 MeV/n Al ions was detected with a home-made silicon photodiode. The diameter of the photodiode was 2 inch. The effective quantum efficiency was observed to be 22% for the wavelength of liquid xenon scintillation light (170 nm), while the effective quantum efficiency for 5.486 MeV alpha-particle excitation was 44%. An energy resolution of 0.5% rms was achieved for the energy deposition of 2.5 GeV in liquid xenon using a fast preamplifier ({approx equal} 20 ns). (orig.).

1991-11-15

95

Computer model of high-latitude scintillation. [WBMOD program  

Energy Technology Data Exchange (ETDEWEB)

The DNA Wideband satellite experiment provided extensive data on scintillation produced in high-altitude structured plasmas. A computer program, WBMOD, is being developed to summarize those data in an applications-oriented way. The program contains the phase-screen scattering theory of Rino and a morphological description of ionospheric irregularities (thus far only at auroral latitudes) based on Wideband observations. It permits a user to compute scintillation indices for both phase and intensity as a function of system operating parameters and solar-ionospheric disturbance level. Correction is made for multiple scatter, and the user may choose either one-way (communication) or two-way (radar) propagation.

1982-01-01

96

Computer model of high-latitude scintillation  

International Nuclear Information System (INIS)

The DNA Wideband satellite experiment provided extensive data on scintillation produced in high-altitude structured plasmas. A computer program, WBMOD, is being developed to summarize those data in an applications-oriented way. The program contains the phase-screen scattering theory of Rino and a morphological description of ionospheric irregularities (thus far only at auroral latitudes) based on Wideband observations. It permits a user to compute scintillation indices for both phase and intensity as a function of system operating parameters and solar-ionospheric disturbance level. Correction is made for multiple scatter, and the user may choose either one-way (communication) or two-way (radar) propagation.

97

Impact of Ionospheric Scintillations on Space-Based ...  

Science.gov (United States)

... Zinn, J., Hoerlin, H., and Petschek, AG, "The Motion of Bomb Debris Follow- ing the Starfish Test," Radiation Trapped in the Earth's Magnetic Field ...

1991-06-01

98

The Effect of Cocktail on Radiocarbon Analysis by Direct Absorption of Carbon dioxide  

International Nuclear Information System (INIS)

Carbon-14 was analysed by direct absorption of carbon dioxide on the mixture of organic amine compound and scintillation cocktail then counted by low level liquid scintillation counter. This method can be applied for radiocarbon dating. In this study, the effects of carbon dioxide absorption, and counting efficiency were investigated using various commercial available cocktail. It was found that permafluor V and Ready Gel showed the highest carbon dioxide absorption whereas the Permafluor V showed the highest counting efficiency

1998-12-01

99

Aqueous liquid scintillation counting with fluor-containing nanosuspensions  

Energy Technology Data Exchange (ETDEWEB)

A microemulsion comprised of water, Brij 78, pentanol and styrene into which PPO and bis-MSB had been dissolved was prepared. Polymerization of the styrene resulted in a suspension of fluor-containing polystyrene nanoparticles (<100 nm). After a concentration step, the aqueous nanosuspension was able to detect {sup 14}C with counting efficiencies over 50% of those of a commercially available scintillation cocktail. Monte Carlo calculations demonstrated that the size and concentration of the nanoparticles were appropriate for optimum detection efficiency.

2004-06-01

100

Mid-latitude scintillation model. Technical report, 1 November 1985-31 October 1986  

Energy Technology Data Exchange (ETDEWEB)

Radiowave scintillation in the presence of ionospheric disturbances has the potential to disrupt numerous transionospheric radio and radar systems. This report describes development of a model characterizing the plasma density irregularities that produce scintillation in the naturally disturbed mid-latitude F layer. The model will be incorporated into Program WBMOD, which includes subroutines for computing both link geometry and scintillation indices, the latter by means of phase screen diffraction theory. Earlier versions of WBMOD, were based on extensive analysis of scintillation data collected in the auroral and equatorial zones in Wideband Satellite Mission. The model described herein is based on similarly extensive analysis of Wideband data from one mid latitude station and of data collected from HiLat satellite at another mid latitude station. The model describes irregularities at an effective ...

1986-10-31

101

A novel method for solving lithium carbonate pellet by binary-acid for tritium production rate measurement by liquid scintillation counting technique  

International Nuclear Information System (INIS)

Lithium carbonate pellets are frequently used for estimation of tritium production rate in irradiated samples in fusion blanket neutronics experiment and the activity is measured by liquid scintillation counting technique. In this measurement, it is essential to solve the lithium carbonate pellet as much as possible and to mix the pellet solution into scintillation cocktail homogeneously at stable condition. For this purpose, a novel binary-acid method has been developed to solve lithium carbonate and to mix the pellet solution into scintillation cocktail. High solubility is attained by adopting two acids, HNO_3 and CH_3COOH, and a good compatibility of the pellet solution with scintillator is obtained by emulsion cocktail resulting in high counting efficiency. Defining a product of dissolved mass and counting efficiency as a Figure of Merit (FOM), the present method has higher FOM value than the ...

102
103

Semiconductor Radiation Detectors with Frisch Collars and Collimators for Gamma Ray Spectroscopy and Imaging  

Energy Technology Data Exchange (ETDEWEB)

To study CdZnTe as a high energy resolution gamma ray detector with a novel new design, and to build a detector array from the new detector design

2006-12-04

108

Small world when building a particle detector prototype, the devil is in the tiny details  

CERN Multimedia

Small world when building a particle detector prototype, the devil is in the tiny details

2004-01-01

109

Development of Novel Polycrystalline Ceramic Scintillators  

Energy Technology Data Exchange (ETDEWEB)

For several decades most of the efforts to develop new scintillator materials have concentrated on high-light-yield inorganic single-crystals while polycrystalline ceramic scintillators, since their inception in the early 1980 s, have received relatively little attention. Nevertheless, transparent ceramics offer a promising approach to the fabrication of relatively inexpensive scintillators via a simple mechanical compaction and annealing process that eliminates single-crystal growth. Until recently, commonly accepted concepts restricted the polycrystalline ceramic approach to materials exhibiting a cubic crystal structure. Here, we report our results on the development of two novel ceramic scintillators based on the non-cubic crystalline materials: Lu SiO:Ce (LSO:Ce) and LaBr:Ce. While no evidence for texturing has been found in their ceramic microstructures, our LSO:Ce ceramics exhibit a surprisingly ...

2008-06-01

110

An analysis on the mid-latitude scintillation and coherence frequency bandwidth using transionospheric VHF signals  

Energy Technology Data Exchange (ETDEWEB)

An analysis was perfonned on the mid-latitude scintillation and coherence frequency bandwidth (Fcoh) using transionospheric VHF signal data. The data include 1062 events spanning from November 1997 to June 2002. Each event records FORTE satellite received VHF signals from LAPP located at Los Alamos, New Mexico. Fcohs were derived to study scintillation characteristics on diurnal and seasonal variations, as well as changes due to solar and geomagnetic activities. Comparisons to the VHFIUHF coherence frequency bandwidth studies previously reported at equatorial and mid-latitude regions are made using a 4th power frequency dependence relationship. Furthennore, a wideband ionospheric scintillation model, WBMOD, was used to estimate Fcohs and compared with our VHF Fcoh values. Our analysis indicates mid-latitude scintillation characteristics that are not previously revealed. At the VHF bottom frequency range ...

2008-01-01

111

Large scintillation cells for high sensitivity radon concentration measurements  

Energy Technology Data Exchange (ETDEWEB)

Methods for improving the sensitivity of scintillation cells for radon concentration measurements were studied with emphasis on improving light collection efficiency. This allows the length and hence the volume of the cell to be increased. Variables studied were choice of scintillator material, its method of application and thickness, length of cell, cell material, type and configuration of reflectors, choice of photomultipliers, and factors affecting background. Response from various areas of the cell surface was studied with an alpha source and with radon filling. Coating the window with phosphor was found to be counter-productive. The optimum results obtained were with the inside of the cell (other than the window) covered with a thick layer of ZnS(Ag), or with a thick layer of reflective material coated with a thin layer of phosphor. With it, a 10 cm diameter plexiglass cell can be extended to at least 50 cm length without difficulty from ...

1983-07-01

112

Large scintillation cells for high sensitivity radon concentration measurements  

International Nuclear Information System (INIS)

Methods for improving the sensitivity of scintillation cells for radon concentration measurements were studied with emphasis on improving light collection efficiency. This allows the length and hence the volume of the cell to be increased. Variables studied were choice of scintillator material, its method of application and thickness, length of cell, cell material, type and configuration of reflectors, choice of photomultipliers, and factors affecting background. Response from various areas of the cell surface was studied with an alphy source and with radon filling. Coating the window with phosphor was found to be counter-productive. The optimum results obtained were with the inside of the cell (other than the window) covered with a thick layer of ZnS(Ag), or with a thick layer of reflective material coated with a thin layer of phosphor. With it, a 10 cm diameter plexiglass cell can be extended to at least 50 cm length without difficulty from ...

113

Thermal-resistant radiation sensing system using optical fiber for monitoring progress of chemical decontamination  

Energy Technology Data Exchange (ETDEWEB)

A thermal-resistant radiation sensing system using optical fiber has been developed. The system is for monitoring progress of chemical decontamination and able to measure the gamma-ray level in a hot solution of decontamination chemicals in situ. Our sensor head makes use of thermal-resistant NaI (T1) and it is connected to an optical fiber bundle. Scintillation photons pass from the NaI (T1) into the end of the bundle. This part of the system can withstand temperatures of over 100degC. At the far end of the optical fiber bundle, the scintillation photons are converted into fluorescent photons using a wavelength-shifting fiber. These photons are transferred to a distant photomultiplier tube through two thin transparent optical fibers. Furthermore, we propose a self-compensation technique for the dependence of scintillator sensitivity on. This compensation method is based on the correlation between temperature, sensitivity, ...

1999-07-01

114

Scintillation proximity assay for measurement of RNA methylation  

UK PubMed Central (United Kingdom)

Methylation of RNA by methyltransferases is a phylogenetically ubiquitous post-transcriptional modification that occurs most extensively in transfer RNA (tRNA) and ribosomal RNA (rRNA). Biochemical...Full Text Available

2009-03-01

115

Radiation damage and recovery in the light emittance efficiency and the attenuation length of barium fluoride scintillator  

International Nuclear Information System (INIS)

Radiation damage and its recovery in the light emittance efficiency and the attenuation length of barium fluoride (BaF_2) scintillator have been investigated. The light yield and transmittance of small samples of BaF_2 scintillator were measured after #gamma#-irradiation from 0.5x10"4 to 1.1x10"5 Gy for deterioration, and after sunlight exposure for recovery. Suspension of deterioration was observed both in light yield and in attenuation length at an integrated dose of #gamma#-rays of about 10"4 Gy. Fairly good and quick recovery of the deteriorated BaF_2 scintillator was obtained by sunlight exposure. Using a Monte Carlo simulation method, the dependence of the light emittance efficiency on #gamma#-irradiation and sunlight exposure was studied. It has been found that the light emittance efficiency, as well as the attenuation length, is influenced by #gamma#-irradiation and sunlight exposure. (orig.).

116

Measurement of cosmic ray neutron spectrum at sea level  

International Nuclear Information System (INIS)

The cosmic ray neutron spectrum at sea level has been measured by the method of pulse shape discrimination in anthracene scintillator. The exponent of the differential spectrum was found to be 2.2+-0.1. (Auth.).

117

Synthesis and scintillation properties of GdCl_3:Ce"3"+ (Gd_1_-_xCe_xCl_3_,x = 0.005-0.08)  

International Nuclear Information System (INIS)

Single crystals of GdCl_3 doped with different concentrations of Ce"3"+ have been grown using the Bridgman-Stockbarger technique and their luminescence and scintillation properties were investigated. The luminescence spectrum of GdCl_3:Ce"3"+ is complex and consists of two bands with maxima at 350 nm and 370 nm. The maximal light yield in GdCl_3:Ce"3"+ was observed at #approx#1 mol% of Ce"3"+ (more than 38 000 ph/MeV).

2009-07-08

118

LUCIFER, a potentially background-free approach to the search for neutrinoless double beta decay  

British Library Electronic Table of Contents (United Kingdom)

LUCIFER (Low-background Underground Cryogenic Installation For Elusive Rates) is a new project for the study of neutrinoless Double Beta Decay, based on the technology of scintillating bolometers. These devices promise a very efficient rejection of the alpha background, opening the way to a virtual background-free experiment if candidates with a transition energy higher than 2615 keV are investigated. The baseline candidate for LUCIFER is 82Se. This isotope will be embedded in ZnSe crystals grown with enriched selenium and operated as scintillating bolometers in a low-radioactivity underground dilution refrigerator. In this paper, the LUCIFER concept will be introduced. The sensitivity and the very promising prospects related to this project will be discussed.

2011-01-01

119

A high-sensitivity scintillation chamber for radon in gas  

Energy Technology Data Exchange (ETDEWEB)

A large scintillation chamber of 6.7 l volume for direct radon concentration measurements in gas is presented. With two 5 in. photomultipliers on opposite sides, working in coincidence, a concentration as low as about 0.5 mBq/l is detectable with 10% standard deviation after 1000 min measuring time. With the achieved background count rate of 0.42 counts/min and the counting efficiency of 0.607 for [sup 222]Rn and its progenies the absolute minimal detectable specific activity is reached with 0.17 mBq/l at about 12 000 min. The method to determine this minimum detectable activity is outlined. ((orig.))

1994-06-15

120

Operation of an 18-fold segmented n-type HPGe detector in liquid nitrogen  

International Nuclear Information System (INIS)

For the first time a segmented n-type HPGe detector was operated directly submerged in liquid nitrogen over a long period. As this kind of detector is envisioned to be used in GERDA phase II, it was operated with a low mass signal cable with snap-contacts and mounted in a low-mass copper holder. The detector performance was stable over 146 days, indicating that neither detector nor contacts deteriorated.

2009-11-01

121

From tomography to voludensitometry: radiation detectors for industrial control and medical instrumentation; De la tomographie a la voludensitometrie: les capteurs pour le controle industriel et l`instrumentation medicale  

Energy Technology Data Exchange (ETDEWEB)

In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).

1993-12-01

122

Bragg curve spectroscopy detector for particle identification  

International Nuclear Information System (INIS)

The operation principle, construction and characteristics of the Bragg curve spectroscopy detector (BCS detector) are described. The electric field of the BCS detector is parallel to the particle trajectories. The detector was tested by 8.78 MeV and 6.02 MeV #alpha# particles from a ThC-ThC's source. The energy resolutions are 1.5% and 2.6% respectively for two groups of #alpha# particles, and the charge resolution is 2.7%. Further test experiments with heavy ions will be arranged.

123

First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry  

Energy Technology Data Exchange (ETDEWEB)

A prototype detector based on the inclined boron layer principle is introduced. For typical measurement conditions at the Liquids Reflectometer at the Spallation Neutron Source, its count rate capability is shown to be superior to that of the current detector by nearly two orders of magnitude.

2010-01-01

124

First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry  

Energy Technology Data Exchange (ETDEWEB)

A prototype detector based on the inclined absorber layer principle is introduced. For the Liquids Reflectometer at the Spallation Neutron Source, it is shown to be a significant improvement over its current detector, which imposes an instantaneous count rate limitation of 50 kcps.

2008-10-01

125

Gamma Radiation Detectors of the TA-55 Waste Line Monitoring System  

Energy Technology Data Exchange (ETDEWEB)

This report covers the gamma detectors, measurement instrumentation, and testing results of a system developed at Los Alamos National Laboratory. This system monitors the process liquid waste streams at the Plutonium Facility (TA-55) for the presence of radioactive contamination. The detectors are at various points on the acid, caustic, and industrial waste lines. Two of the detectors are on the sanitary sewer lines from the facility. A custom interface unit associated with these two detectors furnishes the facility operation center with a notification of the detection of material. All of the detectors furnish measurement information to a central computer system for storage and trending.

1999-06-01

126

First results from the Lund NMP particle detector system  

International Nuclear Information System (INIS)

The design and first results from a Double Sided Silicon Strip Detector (DSSSD) recently installed at the Lund Nuclear Microprobe facility (NMP) are presented. The detector has 64 sector strips and 32 ring strips, which in combination give more than 2000 detector cells, each with characteristics comparable with a standard surface barrier detector (SBD). The detector has been tested both with radioactive sources and with different ion beams and energies. The most striking features are the high rate virtually pile-up free operation and also the possibility of detailed measurement of angular distributions.

2009-06-15

127

First results from the Lund NMP particle detector system  

British Library Electronic Table of Contents (United Kingdom)

The design and first results from a Double Sided Silicon Strip Detector (DSSSD) recently installed at the Lund Nuclear Microprobe facility (NMP) are presented. The detector has 64 sector strips and 32 ring strips, which in combination give more than 2000 detector cells, each with characteristics comparable with a standard surface barrier detector (SBD). The detector has been tested both with radioactive sources and with different ion beams and energies. The most striking features are the high rate virtually pile-up free operation and also the possibility of detailed measurement of angular distributions.

2009-01-01

128

Femtosecond Laser Passivation of GaAs Detector Material  

Science.gov (United States)

... The approach is to perform noise spectral density measurements and selected materials structure measurements on GaAs detector materials, with ...

2008-06-07

129

Design and R&D for the forward calorimeter and silicon tracker of the $\\tau$cF detector  

CERN Document Server

Design and R&D for the forward calorimeter and silicon tracker of the $\\tau$cF detector

1993-01-01

130

A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer  

CERN Document Server

A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer

1991-01-01

131

Method and system for determining depth distribution of radiation-emitting material located in a source medium and radiation detector system for use therein  

Energy Technology Data Exchange (ETDEWEB)

A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the detector as rays parallel to the detector axis of the detector. The ...

2003-03-04

132

Equatorial scintillation model. Technical report, 1 February 1983-30 April 1985  

Energy Technology Data Exchange (ETDEWEB)

Radiowave scintillation in the presence of natural and/or high-altitude nuclear disturbances has the potential to disrupt numerous transionospheric radio and radar systems. This report develops a model characterizing the plasma-density irregularities that produce scintillation in the naturally disturbed equatorial F layer. The model is incorporated into Program WBMOD along with subroutines for computing both link geometry and scintillation indices, the latter by means of phase screen diffraction theory. The model is based on similarly extensive analysis of wideband data from two equatorial stations. It describes irregularities at an effective height of 350 km that are isotropic across the geomagnetic field and elongated by a factor of 50 along the field and whose one-dimensional spatial power spectrum obeys a single-regime power law with a (negative) spectral index of 1.5. The height-integrated spectral strength of the ...

1985-09-30

133

Verification of lithium detector efficiency using DD neutron  

International Nuclear Information System (INIS)

The detection efficiency of a lithium glass detector was calculated using MCNP code, and the calculation was compared with the published results in Pulsed Sphere Plan. A lithium glass detector of our own was made, and its neutron efficiency was calculated. The calculated neutron efficiency was verified with both pulsed and steady DD neutrons. Characteristics of Neutron response of "6Li detector was discussed. (authors)

2005-08-01

134

Use of signal delay of one of detectors in two-channel radiometric flaw detector  

International Nuclear Information System (INIS)

A possibility is considered or reducing the surface heterogeneity effect of an item being tested on the result of radiation flaw detection by means of signal delay of one of detectors in a two-channel radiometric flaw detector. The exposure of a translationally moving item has been studied as well as an external exposure of a rotating hollow item.

135

Resonant-mass detectors of gravitational radiation  

International Nuclear Information System (INIS)

A network of second-generation low-temperature gravitational radiation detectors is nearing completion. These detectors, sensitive to mechanical strains of order 10"-"1"8, are possible because of a variety of technical innovations that have been made in cryogenics, low-noise superconducting instrumentation, and vibration isolation techniques. Another five orders of magnitude improvement in energy sensitivity of resonant-mass detectors is possible before the linear amplifier quantum limit is encountered. 33 references, 3 figures, 1 table.

1987-07-01

139

Developments and tests of double-sided silicon strip detectors and read-out electronics for the Internal Tracking System of ALICE at LHC  

CERN Document Server

The internal-tracking-system (ITS) of the ALICE detector at LHC, consists of six concentrical barrels of silicon detectors. The outmost two layers are made of double-sided strip detectors (SSD). In the framework of a R and D, the characteristics and performances of these devices, manufactured by two different companies, associated with their designed read-out electronics, have been studied off- and in-beam at the SPS (CERN). The results are presented and discussed.

1999-01-01

140

Application of Pd silicide in the process of silicon detectors  

Energy Technology Data Exchange (ETDEWEB)

A new technology called a self-aligned metal-silicide process is described in the fabrication of silicon detectors. It has been found that this technology improves both detector yield and leakage current. The use of a metal silicide also gives a lower contact resistance and, depending on the thermal process, a controllable junction depth, which may be essential in the integration of detectors and their electronics.

1990-04-01

141

ASE FILE  

Science.gov (United States)

radionuclide X-ray fluorescence analysis: the resolving power of the ... The radiation detectors used in radionuclide X-ray fluorescence ...

142

Thin-film UV detectors based on hydrogenated amorphous silicon and its alloys  

Energy Technology Data Exchange (ETDEWEB)

Thin film ultraviolet detectors based on hydrogenated amorphous silicon alloys are realized with different diode structures (PIN, NIP, PN, and NP). The PIN and NIP detectors exhibit higher sensitivity in the ultraviolet spectrum and a significant lower dark current in comparison to the PN or NP structures. The best detector performance was achieved with a 33 nm thick PIN diode. This detector shows a maximum of quantum efficiency of 36.3% at a wavelength of 310 nm. By varying the thickness of the semi-transparent Ag front contact the selectivity of the detectors with the quantum efficiency peak at 320 nm can be adjusted. Thus, the spectral sensitivity of the detector shifts from a broad UV to a selective UV-B spectrum. (orig.)

2001-05-16

143

Influence of Dopants on Characteristics of X-Ray Detectors Fabricated from Indium-, Gallium-, and Chlorine-Doped Cadmium Telluride Single Crystals  

Science.gov (United States)

Counting characteristics of X-ray detectors fabricated from indium-doped, gallium-doped, and chlorine-doped CdTe have been investigated. The detectors fabricated from indium-doped and gallium-doped crystals showed radiation-induced polarization, namely, a progressive decrease of count rate with an increase of photon fluence in the high-photon-fluence region, while the detectors fabricated from chlorine-doped crystals did not. Results from current-voltage characteristics of the detectors indicated that the different counting characteristics of these detectors originated from the difference in internal electric fields in each detector.

1995-08-01

144

Design and fabrication of large ultra-thin PIN detector with membrane stress deviation  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the design of large thin PIN detector with a membrane stress avoidance configuration is proposed, and the related device fabrication process is developed. Ultra-thin PIN detector {approx} 1.13 cm{sup 2} in area is fabricated on a thin ( {approx} 35{mu}m) silicon membrane, and characterized. Detector performance improvement has been successfully demonstrated. With the membrane stress avoidance design, the improved detector exhibits a leakage of 6nA, which is at least 5 times lower than that of detector of identical junction area. The new detector features a full depleted capacitance of 110 pF, and a FWHM of 40.86 keV energy resolution for 5.486 MeV alpha particle spectrography.

2010-09-15

145

Performance of ZnMoO4 crystal as cryogenic scintillating bolometer to search for double beta decay of molybdenum  

CERN Document Server

Zinc molybdate (ZnMoO4) single crystals were grown for the first time by the Czochralski method and their luminescence was measured under X ray excitation in the temperature range 85-400 K. Properties of ZnMoO4 crystal as cryogenic low temperature scintillator were checked for the first time. Radioactive contamination of the ZnMoO4 crystal was estimated as <0.3 mBq/kg (228-Th) and 8 mBq/kg (226-Ra). Thanks to the simultaneous measurement of the scintillation light and the phonon signal, the alpha particles can be discriminated from the gamma/beta interactions, making this compound extremely promising for the search of neutrinoless Double Beta Decay of 100-Mo. We also report on the ability to discriminate the alpha-induced background without the light measurement, thanks to a different shape of the thermal signal that characterizes gamma/beta and alpha particle interactions.

2010-01-01

146

Measurement of the mean energy of the off-axis incident electron without the beam guide. Using a scintillating fiber beam-energy monitor for electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

In the case of total skin electron therapy without the beam guide, the electron beam is scattered just outside the gantry exit, dose uniformity in the field is broken, and dose is spread outside the light field. The aims of this study were to measure the mean energy of the off-axis incident electron beam without the beam guide and to establish a reference for the clinical situation. For the measurement, a 4 MeV electron beam was selected among several energies from the linear accelerator. A scintillating fiber beam energy monitor measured the mean energy of the incident electron beam. This energy monitor is a small, light-weight piece of equipment composed of a wedge absorber, scintillation fiber, and photodiode. We found the relationship between electron energy and the indicated value of the energy monitor by means of the estimation of correction factors for five different kinds of electron energy. The preferable linear correlation of 0.997 of ...

2002-06-01

147

Atmospheric scintillations and laser safety  

Science.gov (United States)

Laser devices are currently in widespread use in particular by armed forces for different tasks. Electro-optical sensors as well as unprotected human eyes are extremely sensitive to laser radiation and can be permanently damaged from direct or reflected beams. Laser damage depends on the interaction between the laser beam and the atmosphere in which it traverses. The atmospheric conditions, including the range, terrain features, turbulence, and atmospheric particulates, may alter the laser's effect on different electro-optical devices and systems. When a laser beam passes through the atmosphere the optical turbulence affects the beam. As a result, temporal intensity fluctuations (scintillations) or spatial variations in intensity within a beam cross-section occur. Atmospheric scintillations pose a safety problem because an observer or sensor can be subjected to the risk of a localized irradiance (local focusing effect) much greater than that ...

2011-09-01

148

Development of high resolution imaging detectors for X-ray astronomy  

Energy Technology Data Exchange (ETDEWEB)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-03-01

149

Development of high resolution imaging detectors for X-ray astronomy  

International Nuclear Information System (INIS)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-01-01

150

Core simulations using actual detector readings for a Canada deuterium uranium reactor  

Science.gov (United States)

This paper reports that, to obtain better simulation results for a Canada deuterium uranium (CANDU) reactor operation, a new simulation method is developed that uses actual detector readings as a correction factor. Detector readings from a CANDU reactor are used to correct the calculated flux distribution during core calculation iterations. A suitable function is found to describe the relationship between the detector flux and the fluxes of mesh points around the detector. The new simulation method is tested by performing numerical calculations for the Wolsung reactor (a CANDU-600). The results show that the new method predicts the core state more accurately with fewer iterations.

1991-02-01

151

Investigation of methods for improving models of ionospheric plasma-density irregularities and radio-frequency scintillation. Technical report  

Energy Technology Data Exchange (ETDEWEB)

Many modern military systems used for communications, command and control, navigation, and surveillance depend on reliable and relatively noise-free transmission of radiowave signals through the earth's ionosphere. Small-scale irregularities in the ionospheric density can cause severe distortion, known as radiowave scintillation, of both the amplitude and phase of these signals. The WBMOD computer program can be used to estimate these effects on a wide range of systems. The objective of this study is to investigate improvements to the WBMOD model based on extensive data sets covering both the equatorial and high-latitude regimes. This report summarizes the work completed during the second year, which include completion of the new models for the equatorial region and initial development of models for the high latitude (auroral and polar cap) region.

1993-11-01

152

Improved model of high-latitude F-region scintillation (WBMOD version 13). Final report, 1 September 1993-31 August 1994  

Energy Technology Data Exchange (ETDEWEB)

Many modern military systems used for communications, command and control, navigation, and surveillance depend on reliable and relatively noise-free transmission of radiowave signals through the earth`s ionosphere. Small-scale irregularities in the ionospheric density can cause severe distortion, known as radiowave scintillation, of both the amplitude and phase of these signals. The WBMOD computer program can he used to estimate these effects on a wide range of systems. The objective of this study is to investigate improvements to the WBMOD model based on extensive data sets covering both the equatorial and high-latitude regimes. This report summarizes the work completed during the third year of this project, which includes completion of the new model for the high-latitude (auroral and polar cap) region of the WBMOD model.

1994-08-31

153

Quantum entanglement, recoherence and information flow in an accelerated detector - quantum field system: Implications for black hole information issue  

CERN Document Server

We study an exactly solvable model where an uniformly accelerated detector is linearly coupled to a massless scalar field initially in the Minkowski vacuum. Using the exact correlation functions we show that as soon as the coupling is switched on one can see information flowing from the detector to the field and propagating with the radiation into null infinity. By expressing the reduced density matrix of the detector in terms of the two-point functions, we calculate the purity function in the detector and study the evolution of quantum entanglement between the detector and the field. Only in the ultraweak coupling regime could some degree of recoherence in the detector appear at late times, but never in full restoration, as an earlier work seems to suggest. We explicitly show that under the most general conditions the detector never ...

2007-01-01

154

Searches for Fast Radio Transients  

CERN Document Server

We discuss optimal detection of fast radio transients from astrophysical objects while taking into account the effects of propagation through intervening ionized media, including dispersion, scattering and scintillation.Our analysis applies to the giant-pulse phenomenon exhibited by some pulsars, for which we show examples, and to radio pulses from other astrophysical sources, such as prompt radio emission from gamma-ray burst sources and modulated signals from extra-terrestrial civilizations.

2003-01-01

155

Search for tachyons associated with extensive air showers in the ground level cosmic radiation  

International Nuclear Information System (INIS)

Events detected in a shielded plastic scintillation counter occurring in the 26 microsec preceding the arrival of an extensive air shower at ground level with local electron density or = 20 m to the -2 power and the 240 microsec after its arrival have been studied. No significant excess of events (tachyons) arriving in the early time domain have been observed in a sample of 11,585 air shower triggers.

1985-08-01

156

Scattered radiation effect on the defect image in high-energy bremsstrahlung introscopy  

International Nuclear Information System (INIS)

Results of the evaluation of the scattered radiation effect on the image of defects in examined products are given. The formula is suggested which characterizes the image of defects on a scintillation screen as well as accumulation factors are calculated by the Monte-Carlo method. Values of fluctuations of absorbed energy in the screen used for the evaluation of sensitivity are experimentally obtained. The effect of high-energy bremsstrahlung on the defect detection is analyzed.

157

Quality engineering and control semiannual progress report November and December 1976 and January--April 1977  

International Nuclear Information System (INIS)

Research and development activities are reported on absorption spectroscopy, calorimetry, electrolysis, emission spectroscopy, fluorimetry gas chromatography, infrared spectroscopy, liquid chromatography, liquid scintillation counting, mass spectroscopy, microscopy, radiometric analysis, and thermal analysis. A group of miscellaneous projects are also described.

158

Phantom simulation device for scintillation cameras  

Energy Technology Data Exchange (ETDEWEB)

A phantom simulation imaging quality control device is described that effectively simulates one centimeter lesions, using steel ball bearings as gamma ray attenuators. The bearings are mounted in a synthetic resinous sheet in an orthogonal pattern. The phantom can provide uniformity, resolution, linearity, distortion and field size checks, all with a single exposure.

1981-08-25

159

New crystals for dual-readout calorimetry  

CERN Document Server

Lead tungstate crystals doped with small fractions of praesodynium or molybdenum have been tested in beams of high-energy electrons. The goal of these tests was to study the effects of such dopants on the capability to separate the signal components deriving from the Cherenkov and scintillation light generated by the beam particles. These studies were carried out in view of the possible application of such crystals in dual-readout calorimeters.

2009-01-01

160

A search for tachyons in extensive air showers  

International Nuclear Information System (INIS)

A search for tachyons, or other particles detectable by G-M counter tubes or liquid scintillators, arriving during the approximately 100#mu#s immediately preceding extensive air showers (primary energy approximately 10"1"5 eV) has provided no positive evidence for the existence of such particles. (orig.).

161

Six orders of magnitude dynamic range in capillary electrophoresis with ultrasensitive laser-induced fluorescence detection  

UK PubMed Central (United Kingdom)

An ultrasensitive laser-induced fluorescence detector was used with capillary electrophoresis for the study of 5-carboxy-tetramethylrhodamine. The raw signal from the detector provided roughly...Full Text Available

2009-12-15

162

Focal plane detector for reactions with medium weight projectiles  

Energy Technology Data Exchange (ETDEWEB)

A new focal plane detector for an Enge split pole spectrograph has been developed which is able to resolve individual elements and isotopes up to the mass 100 region. It consists of a 60 cm long position sensitive parallel plate avalanche counter backed by a large Bragg curve detector. Compared with other position sensitive focal plane counters the new detector system has a very good time resolution (less than 300 ps) and can be operated at much higher counting rates (up to 25 kHz). The intrinsic resolution of the position detector is less than 1 mm. In addition to the energy and the nuclear charge signal obtained from the Bragg curve detector the angle of incidence into the detector can be measured with an accuracy of better than 1/sup 0/. The detector has already been used in a variety of experiments where good timing, counting rate ...

1988-12-01

163

Developments of heavy-ion gas detectors at LNL  

Energy Technology Data Exchange (ETDEWEB)

The most important developments in gaseous detectors at LNL are reviewed. Some aspects of timing, pulse height and position resolutions of avalanche counters are reported. The experimental work on heavy-ion identification by Bragg curve spectroscopy is summarized.

1984-05-01

164

Development of a dual-detector X-ray imaging system for phase retrieval study  

International Nuclear Information System (INIS)

Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two ...

2007-01-01

165

Detection of explosives  

Energy Technology Data Exchange (ETDEWEB)

An analyser for detecting explosives has at least one neutron source and a plurality of gamma ray detectors. An article to be analysed is moved adjacent the source and detectors and is subjected to neutrons which generate gamma rays from any nitrogen in the article. The gamma rays are detected and analysed to determine the nitrogen concentration within the article. In order to achieve an area of uniform detection there are a plurality of detectors equidistant both from the or each source and from the article to be analysed. In order to avoid a decrease in sensitivity away from the source(s) and detectors there may be a second opposing array of source(s) and detectors on the opposite side of the article. For greatest uniformity of detection, a source in one array opposes a detector in the other array and vice versa. Transmission of radiation from the analyser is ...

1991-03-13

166

Conventional detectors for a photon-photon collider  

Energy Technology Data Exchange (ETDEWEB)

Detectors for a photon-photon collider are envisaged using as guide-lines the physics goals and the interaction point environment. Production of SUSY Higgs scalar and pseudo-scalar is emphasized. Some aspects of the interaction point environment are discussed. ((orig.)).

1995-02-01

167

Comparison of Detector Intrinsic Spatial Resolution Characteristics for Sensor on the Entrance Surface and Conventional Readout Designs  

UK PubMed Central (United Kingdom)

We report on a high resolution, monolithic crystal PET detector design concept that provides depth of interaction (DOI) positioning within the crystal. Our design utilizes a novel sensor on...Full Text Available

2010-01-01

168

UNFBENJ: on-line, real-time neutron spectrum unfolding for Benjamin detectors  

International Nuclear Information System (INIS)

(Jun 1978). United States Miller, H. Univ. of Missouri, Columbia Peterman,

1978-06-18

169

The virtual fast-ion loss detector  

International Nuclear Information System (INIS)

English 2009 p. 79 Ukraine Brudgam, M. Lauber, Ph. Garcia Munoz, M.

2009-09-21

170

Radionuclide X-ray fluorescence analysis using semiconductor detectors  

International Nuclear Information System (INIS)

Czech May 1979. p. 32-33. Czechoslovakia Benada, J. Spacek, B. Ustav

1979-05-01

171

Parameter optimization of a planar BEGe detector using Monte Carlo simulations  

International Nuclear Information System (INIS)

This work reports on the use of three state-of-the-art Monte Carlo codes (MCNPX, PENELOPE, FLUKA) in the efficiency calibration of a Broad-Energy Germanium (BEGe) detector. Initial discrepancies found between the experimental and computational efficiency values are related to the poor knowledge of some physical parameters of the detector (dead-layers, crystal dimensions, etc.). As a consequence, a sensitivity analysis was carried out. Each parameter was systematically analyzed, and an accurate model of the detector was determined. The obtained results are consistent, allowing this model to be used in computational efficiency calibrations of the equipment at stake.

2010-11-21

172

Method and system for detecting explosives  

Energy Technology Data Exchange (ETDEWEB)

A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

2009-03-10

173

GCR-induced Photon Luminescence of the Moon: The Moon as a CR Detector  

Science.gov (United States)

We report on the results of a preliminary study of the GCR-induced photon luminescence of the Moon

2007-01-01

174

Explosives detection system and method  

Energy Technology Data Exchange (ETDEWEB)

A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

2007-12-11

176

CMS Silicon Strip Tracker Performance  

CERN Document Server

In this paper we describe the reconstruction strategies, the calibration procedures and the detector performance results from the latest CMS operation.

2011-01-01

177

Advances in imaging THGEM-based detectors  

International Nuclear Information System (INIS)

We report on recent measurements with Thick GEM-like (THGEM)-based imaging detectors. The THGEM is a robust gaseous electron multiplier similar to GEM but with larger dimensions. It has high electron multiplication, of 105 and 107 in single- and double-THGEM structure, respectively, fast signals and ?10MHz/mm2 counting rate capability. It can be produced in any shape and over large area. In view of many possible applications of THGEM-based imaging detectors, in particle physics and beyond, we have recently studied the localization properties of a 2D 10x10cm2 detector. The results of these studies are presented.

2007-03-01

178

A new technique for radon measurement based on a combination of a track-etch detector and activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

A new technique for radon measurement in the natural environment was investigated. It is based on the use of activated charcoal and a track-etch detector. The charcoal acts as a radon collector from the air and the track-etch detector as a recorder of the alpha particles emitted by radon and its decay products. Our preliminary results show that the response of the new dosimeter to radon, using Deodorant activated charcoal (TOK, Yugoslavia) and a CR-39 track-etch detector, is 1.4 tracks cm{sup -2}/Bqm{sup -3}d, which is about eight times higher than that obtained with a standard track-etch dosimeter. (author).

1991-01-01

179

Using neutron-activation detectors with fissionable nuclides  

Energy Technology Data Exchange (ETDEWEB)

Presented are results of a test of a method for measuring neutron fluences using detectors with fissionable nuclides. The investigations show the soundness of of using neutron-activation detectors of the type Am for mesurements in nuclear installations for values of thermal-neutron fluence of from 10/sup 13/ to 10/sup 20/ neutrons/cm/sup 2/ with exposure for up to several months. The proposed method can be used for prolonged measurements in strong fields of both thermal and fast neutrons.

1986-09-01

180

Test of superconducting Nb/Al bilayers as particle detectors  

Energy Technology Data Exchange (ETDEWEB)

Superconducting thin film particle detectors can be very attractive due to the low sensitivity to radiation damage. We describe the fabrication procedure and the characterization of Nb/Al bilayers as particle detectors. First steady and dynamical results are reported from tests of 5 MeV alpha-particle detection.

2000-04-07

181

Position detector design using an electrostatic application of ANSYS[sup TM  

Energy Technology Data Exchange (ETDEWEB)

The design of beam position monitor (BPM) stripline detectors has been enhanced by using the finite element code ANSYS[sup TM]. Available from Swanson Engineering, ANSYS[sup TM] was developed to solve Poisson's equation in stress and thermal analysis applications. The code is readily adaptable to solving electrostatic problems. The designs of several beam detectors were iterated by calculating electrode capacitances and characteristic impedances to better than 1% accuracy.

1994-10-10

182

Performance of CDF calorimeter simulation for Tevatron Run II  

Energy Technology Data Exchange (ETDEWEB)

The upgraded CDF II detector has collected first data during the initial operation of the Tevatron accelerator in Run II. The simulation of the CDF electromagnetic and hadronic central and upgraded plug (forward) calorimeter is based on the Gflash calorimeter parameterization package used within the GEANT based detector simulation of the Run II CDF detector. We present the results of tuning the central and plug calorimeter response to test beam data.

2002-09-19

183

Neutronic detection device with extended flux range for control of nuclear reactors. Dispositif de detection neutronique a dynamique etendue pour le controle et la commande des reacteurs nucleaires  

Energy Technology Data Exchange (ETDEWEB)

The neutron detector is cased in a metal envelop and has one detector with a very sensitive fission chamber and a second detector with a fission chamber less sensitive that the first one and a boron coated ionisation chamber for reducing gamma radiation detection.

1992-06-12

184

Fundamental understanding of aging processes Review of the workshop results  

CERN Document Server

A study on the aging process of gas detectors was presented. How the development of more performing but delicate detectors, the use of faster but aggressive gases, and the need to cover large areas, led to unexpected problems was discussed. Various methods for curing aged detectors were also highlighted. (Edited abstract) 37 Refs.

2003-01-01

185

A comparison of x-ray detectors for mouse CT imaging  

International Nuclear Information System (INIS)

There is significant interest in using computed tomography (CT) for in vivo imaging applications in mouse models of disease. Most commercially available mouse x-ray CT scanners utilize a charge-coupled device (CCD) detector coupled via fibre optic taper to a phosphor screen. However, there has been little research to determine if this is the optimum detector for the specific task of in vivo mouse imaging. To investigate this issue, we have evaluated four detectors, including an amorphous selenium (a-Se) detector, an amorphous silicon (a-Si) detector with a gadolinium oxysulphide (GOS) screen, a CCD with a 3:1 fibre taper and a GOS screen, and a CCD with a 2:1 fibre taper and both GOS and thallium-doped caesium iodide (CsI:Tl) screens. The detectors were evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), detective quantum ...

2004-12-07

186

Adaptive Waveform Correlation Detectors for Arrays: Algorithms for Autonomous Calibration  

Energy Technology Data Exchange (ETDEWEB)

Waveform correlation detectors compare a signal template with successive windows of a continuous data stream and report a detection when the correlation coefficient, or some comparable detection statistic, exceeds a specified threshold. Since correlation detectors exploit the fine structure of the full waveform, they are exquisitely sensitive when compared to power (STA/LTA) detectors. The drawback of correlation detectors is that they require complete knowledge of the signal to be detected, which limits such methods to instances of seismicity in which a very similar signal has already been observed by every station used. Such instances include earthquake swarms, aftershock sequences, repeating industrial seismicity, and many other forms of controlled explosions. The reduction in the detection threshold is even greater when the techniques are applied to arrays since stacking can be performed on the ...

2009-07-23

187

Development and operational experience of traveling in core probe drive for flux scan of 540 MWe PHWR of Tarapur  

International Nuclear Information System (INIS)

TAPP-3 and 4 reactors use large number of Self Powered Neutron Detectors (SPNDs) for Neutronic lower measurement and control. To perform in-situ calibration of these detectors in select locations and to validate the reactor physics codes which predict flux at various points in the core, traveling in-core probes (TIP) are required. The TIP assembly consists of a miniature neutron sensitive detector. The detector is driven in and out of core using a mechanism which facilitates positioning of the detector anywhere inside a vertical tube (Central carrier tube of any of the six select Vertical Flux Units) in the core. TIP is driven through retractable feed mechanism for a stroke of 13 m. This paper describes the developmental efforts and the operational feedback of the retractable feed mechanism for the stroke of 13 m used at TAPP 3 and 4 reactor. (author)

2006-11-13

188

Calibration of solid state nuclear track detector CR-39 for radon measurements  

Energy Technology Data Exchange (ETDEWEB)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

2007-07-01

189

Calibration of solid state nuclear track detector CR-39 for radon measurements  

International Nuclear Information System (INIS)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

190

A new method of imaging particle tracks in solid state nuclear track detectors  

British Library Electronic Table of Contents (United Kingdom)

Summary Solid state nuclear track detectors are used to determine the concentration of a particles in the environment. The standard method for assessing exposed detectors involves 2D image analysis. However 3D imaging has the potential to provide additional information relating to angle as well as to differentiate clustered hit sequences and possibly energy of a particles but this could be time consuming. Here we describe a new method for rapid high-resolution 3D imaging of solid state nuclear track detectors. A `LEXT' OLS3100 confocal laser scanning microscope (Olympus Corporation, Tokyo, Japan) was used in confocal mode to successfully obtain 3D image data on four CR-39 plastic detectors. Three-dimensional visualization and image analysis enabled characterization of track features. This ...

2010-01-01

191

A method to study heavy ion reactions using position sensitive and Bragg curve spectroscopy detectors  

Energy Technology Data Exchange (ETDEWEB)

A large area Bragg curve spectroscopy (BCS) detector and a position sensitive parallel grid avalanche counter have been developed to study heavy ion reactions, such as inelastic excitations and few nucleon transfer reactions near the Coulomb barrier. Reasonably good resolutions have been achieved for energy, atomic number and angle. A theoretical investigation on the mass dependence of the Bragg peak signal from the BCS detector, shows that there is a negligible mass dependence related to the geometry of the detector. The mass number of the heavy ions which cannot be obtained by the above method, has been identified by detecting the corresponding characteristic gamma rays from the product nuclei with two large solid angle gamma ray detectors. (orig.)

1993-10-15

192

A method to study heavy ion reactions using position sensitive and Bragg curve spectroscopy detectors  

International Nuclear Information System (INIS)

A large area Bragg curve spectroscopy (BCS) detector and a position sensitive parallel grid avalanche counter have been developed to study heavy ion reactions, such as inelastic excitations and few nucleon transfer reactions near the Coulomb barrier. Reasonably good resolutions have been achieved for energy, atomic number and angle. A theoretical investigation on the mass dependence of the Bragg peak signal from the BCS detector, shows that there is a negligible mass dependence related to the geometry of the detector. The mass number of the heavy ions which cannot be obtained by the above method, has been identified by detecting the corresponding characteristic gamma rays from the product nuclei with two large solid angle gamma ray detectors. (orig.).

193

A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements  

Energy Technology Data Exchange (ETDEWEB)

A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with ...

1991-09-01

194

A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements  

International Nuclear Information System (INIS)

A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with ...

195

A Versatile Evaporative Cooling System Designed for Use in an Elementary Particle Detector  

British Library Electronic Table of Contents (United Kingdom)

An evaporative cooling system developed for operation and qualification testing of silicon pixel and microstrip detectors for the inner tracking detector of the CERN ATLAS spectrometer is described. Silicon detector substrates must be continuously operated between 0 and ???7?C in the high radiation environment near the circulating beams at the CERN Large Hadron Collider (LHC). This requirement imposes unusual constraints on the cooling system and has led to the choice of perfluoro-n-propane (C3F8) refrigerant, which combines good chemical stability under ionizing radiation with high dielectric strength and nonflammability. Since the silicon detectors must also be of extremely light construction to minimize undesirable physics background, coolant tubes are of thin (200 ?m) aluminum wall, wh...

2007-01-01

196

A Detector for 2-D Neutron Imaging for the Spallation Neutron Source  

Energy Technology Data Exchange (ETDEWEB)

Abstract - We have designed, built, and tested a 2-D pixellated thermal neutron detector. The detector is modeled after the MicroMegas-type structure previously published for collider-type experiments. The detector consists of a 4X4 square array of 1 cm 2 pixels each of which is connected to an individual preamplifier-shaper-data acquisition system. The neutron converter is a 10B film on an aluminum substrate. We describe the construction of the detector and the test results utilizing 252Cf sources in Lucite to thermalize the neutrons.Drift electrode (Aluminum) Converter (10B) 3 mm Conversion gap neutron (-900 V)

2006-07-01

197

Neutron detector counting capabilities for /sup 10/B-lined and /sup 235/U fission chambers in high gamma-ray fluxes  

Energy Technology Data Exchange (ETDEWEB)

This report compares the performance characteristics of /sup 10/B-lined and fission-neutron detectors in gamma-ray fluxes typical of the fields to be encountered during nondestructive testing of irradiated light-water fuel assemblies stored in water. Using the optimum time constants for each of the /sup 10/B-lined detectors, the 0.25-in.-dia detector had a 5% loss in neutron count sensitivity at 7000 rad/h. Similarly, the 0.5-in.-dia detector had a 7% loss at 13,000 rad/h and the 1-in.-dia detector had a 5% loss in sensitivity at 1000 rad/h. Uranium-235 fission chambers were operated successfully in fields above 100,000 rad/h with no loss in neutron counting sensitivity. Shielding calculations were done to determine the appropriate shield thickness needed for a /sup 10/B-lined neutron detector to operate in a 50,000 rad/h field, typical of light-water-reactor ...

1985-03-01

198

Large area, low capacitance Si(Li) detectors for high rate x-ray applications  

Energy Technology Data Exchange (ETDEWEB)

Large area, single-element Si(Li) detectors have been fabricated using a novel geometry which yields detectors with reduced capacitance and hence reduced noise at short amplifier pulse-processing times. A typical device employing the new geometry with a thickness of 6 mm and an active area of 175 mm 2 has a capacitance of only 0.5 pf, compared to 2.9 pf for a conventional planar device with equivalent dimensions. These new low capacitance detectors, used in conjunction with low capacitance field effect transistors, will result in x-ray spectrometers capable of operating at very high count rates while still maintaining excellent energy resolution. The spectral response of the low capacitance detectors to a wide range of x-ray energies at 80 K is comparable to typical state-of-the-art conventional Si(Li) devices. In addition to their low capacitance, the new devices offer other advantages over ...

1992-10-01

199

Experimental Evaluation And Simulation Of Multi-pixel Cadmium-zinc-telluride Hard-x-ray Detectors  

CERN Document Server

This dissertation describes the evaluation of many-pixel Cadmium-Zinc-Telluride (CdZnTe) hard-X-ray detectors for future use with the High Energy Replicated Optics (HERO) telescope being developed at Marshall Space Flight Center. The detector requirements for the HERO application are good energy resolution (sufficient to resolve cyclotron features and nuclear lines), spatial resolution of ∼200 μm, minimal charge loss of absorbed X rays, and minimal sensitivity to the background environment. This research concentrates on assessing the suitability of these detectors for the focus of HERO, and includes the development of a simulation of the physics involved in an X-ray-detector interaction, a study of the intrinsic material properties, measurements with prototype detectors such as the energy and spatial resolution, charge loss, and X-ray background reduction through ...

2004-01-01

200

Standardization of "2"4"1Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting  

International Nuclear Information System (INIS)

The nuclide "2"4"1Am decays by alpha emission to "2"3"7Np. Most of the decays (84.6%) populate the excited level of "2"3"7Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of "2"4"1Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

2009-09-07

201

Neutron radiography with the cyclotron, 4  

International Nuclear Information System (INIS)

A real-time neutron radiography system was installed at the neutron radiography facility of Sumitomo Heavy Industries where a sub-compact cyclotron is used as a neutron generator and nominal neutron flux was observed as 1.1 x 10"6 n/cm"2/sec. Preliminary tests were made for various kinds of such components as collimators, scintillators, cameras and lenses and the system was chosen to give the highest quality images. Especially for the scintillator screen, screening tests were carried out for compounds of LiF/ZnS(Ag) and Gd_2O_3/ZnS(Ag) by radiographic film method. The neutron radiography image was converted to fluorescent images by means of the converter and observed by a SIT type TV camera. The video signal was directly displayed on a CRT or after processed with digital image processing devices. The characteristics of this system as for the resultant resolution are presented together with some actual application to dynamical fluid motion of ...

1986-01-01

202

Use of activated charcoal for the purification of neon in the CLEAN experiment  

Energy Technology Data Exchange (ETDEWEB)

Passage of neon gas through activated charcoal is planned to be the primary method of removing impurities from the liquid neon scintillator in the CLEAN experiment. In order to quantify this technique, the breakout curves for hydrogen, nitrogen, argon and krypton impurities in neon-saturated activated charcoal were measured. Adsorption coefficients and the number of theoretical stages were measured for hydrogen in the temperature range between 300 and 80 K, nitrogen between 300 and 200 K, and argon between 300 and 190 K. The adsorption coefficient for krypton was measured at 300 K.

2007-01-21

203

The AMS-02 electromagnetic calorimeter  

CERN Document Server

The Electromagnetic Calorimeter (ECAL) of the AMS-02 experiment is a lead-scintillating fibers sampling calorimeter characterized by high granularity that allows to image the longitudinal and lateral showers development, a key issue to provide high electron/hadron discrimination. The light collection system and the FE electronics are designed to let the calorimeter operate over a wide energy range from few GeV up to 1 TeV. A full-scale prototype of the e.m. calorimeter was tested at CERN in October 2001 using electrons and pions beams with energy ranging from 3 to 100 GeV. Effective sampling thickness, linearity and energy resolution were measured. (8 refs).

2002-01-01

204

Radon grab sampling in water by means of radon transfer in activated charcoal collectors  

Energy Technology Data Exchange (ETDEWEB)

The proposed portable device is suitable for radon surveys in water-bearing strata. It allows a complete transfer in activated charcoal canisters of radon dissolved in water collected with a 0.61 bottle. The detection is performed in laboratory with a low background {gamma}-ray spectrometer utilizing 3{sup x}3{sup N}aI({tau}I) scintillator only after about ten hours. This time is necessary to let radon be uniformly distributed within the activated charcoal.

1999-08-01

205

Preliminary study of the {alpha} ratio measurement, ratio of the neutron capture cross section to the fission one for {sup 233}U, on the PEREN platform. Development and study of the experimental setup; Etude preliminaire de la mesure du rapport {alpha}, rapport de la section efficace moyenne de capture sur celle de fission de l'{sup 233}U, sur la plateforme PEREN. Developpement et etude du dispositif experimental  

Energy Technology Data Exchange (ETDEWEB)

Producing nuclear energy in order to reduce anthropic CO{sub 2} emission and to meet high energy demand, implies three conditions to the nuclear plants of the IV. generation: safety improvements, radioactive waste minimization, and fuel breeding for a sustainable use of the resources. The Thorium fuel cycle used in Molten Salt Reactors seems promising. Many numerical studies based on probabilistic codes are carried out in order to analyse the behaviour of such reactors. Nevertheless, one of the most important parameters is badly known: the alpha ratio of {sup 233}U, ratio of the neutron capture cross section to fission one for {sup 233}U. This key-parameter is necessary to calculate the breeding ratio and thus, the deployment capacities of those reactors. This Ph-D thesis was intended to prepare a precise measurement of the alpha ratio of {sup 233}U between 1 eV and 10 keV. Preliminary measurements have been performed on the experimental platform PEREN. This experimental environment is ...

2007-12-15

206

Implantation of an electronic system for real time neutron graphic images acquisition at the IPEN/CNEN Argonaut reactor  

International Nuclear Information System (INIS)

The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)

2004-04-01

207

A Virtual Young's Double Slit Experiment for Hard X-ray Photons  

CERN Document Server

We have implemented a virtual Young's double slit experiment for hard X-ray photons with micro-fabricated bi-prisms. We observe fringe patterns with a scintillator, and quantify interferograms by detecting X-ray fluorescence from a scanned 30nm Cr metal film. The observed intensities are best modeled with a near-field, Fresnel analysis. The maximum fringe number in the overlap region is proportional to the ratio of real to imaginary parts refractive index of the prism material. The horizontal and vertical transverse coherence lengths at beamline APS 8-ID are measured.

2009-01-01

208

Understanding the peak asymmetry in alpha liquid scintillation with {beta}/{gamma} discrimination  

Energy Technology Data Exchange (ETDEWEB)

The peak evaluation in alpha liquid scintillation is known to be easy, mostly due to the gaussian shape of the peaks. However, we often observed a high-energy tail in addition to a pure gaussian function. This effect is only detectable with a high resolution {alpha} liquid scintillation spectrometer such as the PERALS trademark system. Indeed, its intrinsic resolution (180 keV for a 4 MeV {alpha} particle) is better than that obtained for conventional LSC spectrometers. The peak asymmetry was quantified using the Fisher's coefficient {gamma}{sub 1} (symmetry factor). We show that the main effect responsible for the asymmetry is internal conversion. Indeed, most of the even-even nuclides have low {alpha} intensity transitions leading to excited levels of their daughter nuclides. The internal conversion is almost equal to 100% and consequently produces a sum peak at higher energy. No generalization is possible for odd-even nuclides, but ...

2000-07-01

209

Uncertainties of retrospective radon concentration measurements by multilayer surface trap detector  

Energy Technology Data Exchange (ETDEWEB)

The detector for retrospective radon exposure measurements is developed. The detector consists of the multilayer package of solid-state nuclear track detectors LR-115 type. Nitrocellulose films works both as {alpha}-particle detector and as absorber decreasing the energy of {alpha}-particles. The uncertainties of implanted {sup 210}Pb measurements by two- and three-layer detectors are assessed in dependence on surface {sup 210}Po activity and gross background activity of the glass. The generalized compartment behavior model of radon decay products in the room atmosphere was developed and verified. It is shown that the most influencing parameters on the value of conversion coefficient from {sup 210}Po surface activity to average radon concentration are aerosol particles concentration, deposition velocity of unattached {sup 218}Po and air exchange rate. It is demonstrated that with ...

2006-07-01

210

Pulse Rise Time Characterization of a High Pressure Xenon Gamma Detector for use in Resolution Enhancement  

CERN Document Server

High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics ...

2000-01-01

211

Physics of the {sup 252}Cf-source-driven noise analysis measurement  

Energy Technology Data Exchange (ETDEWEB)

The {sup 252}Cf-source-driven noise analysis method is a versatile measurements tool that has been applied to measurements for initial loading of reactors, quality assurance of reactor fuel elements, fuel processing facilities, fuel reprocessing facilities, fuel storage facilities, zero-power testing of reactors, verification of calculational methods, process monitoring, characterization of storage vaults, and nuclear weapons identification. This method`s broad range of application is due to the wide variety of time- and frequency domain signatures, each with unique properties, obtained from the measurement. The following parameters are obtained from this measurement: average detector count rates, detector multiplicities, detector autocorrelations, cross-correlation between detectors, detector autopower spectral densities, cross-power spectral densities between ...

1997-02-01

212

Electronics for the Si detectors in APEX  

Energy Technology Data Exchange (ETDEWEB)

APEX (ATLAS Positron EXperiment), a collaborative effort of ANL, FSU, MSU/NSCL, Princeton, Queen`s, Rochester, Washington and Yale, is an experiment to study positron and electron production in very heavy ion collisions. The electrons and positrons are detected with two detector arrays, each consisting of 216 1 mm thick Si PIN diodes, and their energy and time-of-flight are measured. The number of detectors and limited space made it necessary to develop a system that could efficiently process and transfer signals from the detectors to the charge sensing ADC`s and data readout electronics as well as monitor the condition of the detectors. The discussion will cover the electronics designed for the Si detectors, including the charge amplifier, ``Mother board`` for the charge amplifiers, 8 channel Shaper, 16 channel Constant Fraction Discriminator (CFD), 16 channel Peak-to-FERA (PTF) ...

1994-07-01

213

Development of Micromegas-like gaseous detectors using a pixel readout chip as collecting anode  

International Nuclear Information System (INIS)

This thesis reports on the fabrication and test of a new gaseous detector with a very large number of readout channels. This detector is intended for measuring the tracks of charged particles with an unprecedented sensitivity to single electrons of almost 100 %. It combines a metal grid for signal amplification called the Micromegas with a pixel readout chip as signal collecting anode and is dubbed GridPix. GridPix is a potential candidate for a sub-detector at a future electron linear collider (ILC) foreseen to work in parallel with the LHC around 2020--2030. The tracking capability of GridPix is best exploited if the Micromegas is integrated on the pixel chip. This integrated grid is called InGrid and is precisely fabricated by wafer post-processing. The various steps of the fabrication process and the measurements of its gain, energy resolution and ion back-flow property are reported in this document. Studies of the ...

214

Characterization of 3D thermal neutron semiconductor detectors  

International Nuclear Information System (INIS)

Neutron semiconductor detectors for neutron counting and neutron radiography have an increasing importance. Simple silicon neutron detectors are combination of a planar diode with a layer of an appropriate neutron converter such as 6LiF. These devices have limited detection efficiency of not more than 5%. The detection efficiency can be increased by creating a 3D microstructure of dips, trenches or pores in the detector and filling it with a neutron converter. The first results related to the development of such devices are presented. Silicon detectors were fabricated with pyramidal dips on the surface covered with 6LiF and then irradiated by thermal neutrons. Pulse height spectra of the energy deposited in the sensitive volume were compared with simulations. The detection efficiency of these devices was about 6.3%. Samples with different column sizes were fabricated to study the electrical properties ...

2007-06-11

215

The cross-coupled interferometer for gravitational wave detection  

International Nuclear Information System (INIS)

The cross-coupled interferometer is a new design for interferometric gravitational wave detectors. Similar to the baseline gravitational wave detectors proposed for Advanced LIGO, it uses long-arm cavities in which the signal is generated. The signal fields are then extracted from the arm cavities with an additional cavity behind the long-arm cavities. The tuning of this signal extraction cavity and the parallel tuning of the signal recycling mirror can be used to optimize the peak frequency and the bandwidth of the detector independently. If we replace the signal recycling mirror by a small cavity, it is possible to amplify signals in two different frequency bands.

2002-04-07

216

Tests with superconducting re-entrant cavities for transducer applications in gravitational wave detectors  

International Nuclear Information System (INIS)

We studied the niobium re-entrant cavity utilized by the Australian group in the Niobe gravitational wave detector. Instead of using their non-contact re-entrant cavity, we plan to change it to a closed one to be used in the parametric transducers of the Brazilian Mario Schenberg detector. The performance of the transducer depends on some cavity parameters such as the electrical Q and the electrical coupling. We measured the resonant frequency and the loaded electrical Q as a function of the probe position in a closed niobium #approx#15 GHz cavity operating at 4.2 K.

2004-03-07

217

Sudbury neutrino detector  

International Nuclear Information System (INIS)

The proposed Sudbury Neutrino Observatory is based on a Cherenkov detector which has a total of 1000 tonne of heavy water and 1800 tonne of light water for its sensitive volume. The detector is optimized for the measurement of extra-terrestrial low energy electron neutrinos and electron antineutrinos spectra as well as the total neutrino flux independent of neutrino flavours. It will delineate the Standard Solar Model and neutrino propagation aspects of the solar neutrino problem, provide detailed information on the dynamics of stellar collapse and measure neutrino masses and oscillation parameters with high sensitivity.

218

Studies of a Poenitz-type black neutron detector as a neutron flux monitor  

Energy Technology Data Exchange (ETDEWEB)

A black neutron detector of novel design has been constructed and tested as a neutron flux monitor. The neutron time-of-flight (TOF) technique was used to measure the zero degree neutron spectrum from a subnanosecond pulsed proton beam on a thick metallic lithium target. We describe the detector, discuss the shielding arrangement and electronics, determine the low-energy cut-off. We calculate the efficiency, show spectra and compare measured zero degree differential cross-section of the {sup 7}Li(p, n{sub 0}){sup 7}Be reaction with recommended published cross-sections. (orig.).

1997-04-01

219

Silicon Detector Letter of Intent  

Energy Technology Data Exchange (ETDEWEB)

This document presents the current status of SiD's effort to develop an optimized design for an experiment at the International Linear Collider. It presents detailed discussions of each of SiD's various subsystems, an overview of the full GEANT4 description of SiD, the status of newly developed tracking and calorimeter reconstruction algorithms, studies of subsystem performance based on these tools, results of physics benchmarking analyses, an estimate of the cost of the detector, and an assessment of the detector R&D needed to provide the technical basis for an optimised SiD.

2010-05-26

220

Nuclear borehole logging using lithium detector assemblies  

International Nuclear Information System (INIS)

A method and apparatus for nuclear borehole logging, and in particular, neutron porosity logging, uses a neutron source, and a pair of spaced lithium detectors, preferably Li"6I crystal or Li"6 doped glass, to detect neutrons emitted from a borehole formation being logged. The spectrum developed by the lithium detectors is processed to remove the gamma ray background radiation and the hydrogen absorption peak, thus allowing a more accurate neutron count. A Gaussian curve is fitted to the neutron peak of the spectrum, the curve eliminating the hydrogen absorption peak. The area under this Gaussian curve represents the neutron count. (author).

1991-11-01

221

Applications of the Long-Range Alpha Detector (LRAD) technology to low-level radioactive waste management  

Energy Technology Data Exchange (ETDEWEB)

Long-Range Alpha Detector (LRAD) systems are designed to monitor alpha contamination by measuring the number of ions in the air. Alpha particles are a form of ionizing radiation and a typical 5-MeV alpha particle will create about 150,000 ion pairs in air. Field tests at various DOE sites have shown that LRAD Surface Soil Monitors (SSM), Sample Monitors, and Object Monitors are faster and more sensitive than traditional alpha detectors for measuring alpha contamination. This paper discusses the various applications of LRAD technology to low-level radioactive waste management.

1993-12-01

222

A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection  

Energy Technology Data Exchange (ETDEWEB)

A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

1991-05-01

223

A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection  

International Nuclear Information System (INIS)

A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

224

A PDA-Based ECG Beat Detector for Home Cardiac Care.  

Science.gov (United States)

Recent rapid growth in mobile computing technologies enables telemedicine applications to operate on mobile devices. Our focus is on the design of an integrated electrocardiogram (ECG) beat detector on a Personal Digital Assistant (PDA) platform for the health screening process. The ECG beat detector module will be supported by the PDA version of Personal Health Information Management System (PHIMS) and Facilitated Accurate Referral Management System (FARMS) through wireless network infrastructure as a home-based mobile cardiac monitoring solution. PMID:17282192

2005-01-01

225

View Record - NASA Jet Propulsion Laboratory  

Science.gov (United States)

Jan 13, 2011 ... This 360-degree mosaic of images from the navigation camera on ... The Radiation Assessment Detector, shown prior to its September 2010 ...

226

The mass dependence of the signal peak height of a Bragg-curve ionization chamber  

International Nuclear Information System (INIS)

The Bragg-curve detector of the parallel plate ionization chamber type generates a signal that is a distorted replica of the original Bragg-curve. In result of this distortion, the signal peak height is not only a function of the atomic number of the heavy ion, as it is often stated, but also of the particle mass. This mass effect was studied with the aid of computer simulation, and it was found to be dependent on the Frisch grid to anode gap width and on the detector gas. The charge resolution of the detector is affected very significantly by this mass dependence of the signal peak height. Therefore, a careful selection of the detector gas and the grid to anode gap width is necessary, if good charge resolution over a wide range of heavy ions is required. (orig.).

227

The CDF intermediate silicon layers detector  

Energy Technology Data Exchange (ETDEWEB)

The intermediate silicon layers detector (ISL) was proposed as a part of the upgraded CDF detector at the RUN-II of the Tevatron mean value of pp collider at Fermilab, scheduled to start in year 2000. The ISL is a large-radius (20-30 cm) silicon tracker with a total active area of about 3.5 m. Located in the region between the silicon vertex detector and the central outer tracker, the ISL will allow tracking in the forward region and significantly improve it in the central area. Together with the SVX II the ISL forms a standalone, 3D silicon tracker. The challenge is to build a low-cost device which provides precise 3 D tracking in a approximately equal to 2 m long area with a minimal amount of material for the supporting structure. The conceptual design and the status of the project are reviewed.

1999-11-01

228

The Brazilian Bragg curve detector built for AMS studies  

Energy Technology Data Exchange (ETDEWEB)

A Bragg curve detector (BCD) has been designed and built to be used for AMS purposes. Its design is described and its performance, obtained in tests at the Australian National University (ANU), is reported. At a {sup 36}Cl energy of 154 MeV, the energy resolution was found to be 0.38%, and the charge resolution 1.3%. The {sup 36}Cl and {sup 36}S are completely discriminated. Good separation was also achieved at 64 MeV, and a measurement at this energy of the {sup 36}Cl/Cl ratio of a sample measured previously at 154 MeV with the standard ANU ionization detector agreed well with the earlier value. This very simple detector has been shown to be suitable for use in AMS programs.

2000-10-01

229

Studies of relativistic heavy ion collisions at the AGS (Experiment 814)  

Energy Technology Data Exchange (ETDEWEB)

This report discusses the experimental setup of experiment 814 at Brookhaven AGS. This experiment involves the collision of silicon ions with target nuclei. The detector systems are discussed primarily. (LSP)

1990-01-01

230

Studies of crystalline CdZnTe radiation detectors and polycrystalline thin film CdTe for X-ray imaging applications  

CERN Document Server

The development of a replacement to the conventional film based X-ray imaging technique is required for many reasons. One possible route for this is the use of a large area film of a suitable semiconductor overlaid on an amorphous silicon readout array. A suitable semiconductor exists in cadmium telluride and its tertiary alloy cadmium zinc telluride. In this thesis the spectroscopic characteristics of commercially available CZT X- and gamma-radiation detectors are established. The electronic, optical, electro-optic, structural and compositional properties of these detectors are then investigated. The attained data is used to infer a greater understanding for the carrier transport in a CZT radiation detector following the interaction of a high energy photon. Following this a method used to fabricate large area films of CdTe on a commercial scale is described. This is cathodic electrodeposition from an aqueous electrolyte. ...

2001-01-01

231

Space Images - NASA Jet Propulsion Laboratory  

Science.gov (United States)

Jan 18, 2011 ... The Radiation Assessment Detector, shown prior to its September 2010 ... This 360-degree panorama shows the vista from the location where ...

232

Screening Samples with a Position-Sensitive Detection System Providing Isotope-Specific Information  

International Nuclear Information System (INIS)

The properties of individual radioactive particles present in a sample, such as a swipe, are more interesting than bulk properties of the sample. The present work focuses on instrumentation that provides position-sensitive spectral information non-destructively from the sample. The experimental part of the work was realized using a device called PANDA (Particles And Non-Destructive Analysis). The detector setup used in the study contains a broad-energy HPGe gamma-ray detector and a position-sensitive alpha detector. Both detectors are connected to a time-stamping event-mode data acquisition system. The method is shown to locate particles with sub-millimetre accuracy and distinguish the interesting particles from non-interesting ones. (author)

2010-11-01

233

Radon concentration measurements by means of nuclear tracks detector with image analysis  

International Nuclear Information System (INIS)

English 1998 p. 124 Poland Antanasijevic, R. Vukovic, J. Novakovic, V. Tasic,

1998-09-15

234

Photoconductive ultraviolet detectors based on ZnO films  

British Library Electronic Table of Contents (United Kingdom)

Properties of photoconductive ultraviolet detectors fabricated on ZnO films were presented. Highly c-axis oriented ZnO films were grown on glass substrates by pulsed laser deposition. Ultraviolet photodetectors were fabricated based on metal-semiconductor-metal planar structures. The photoresponsivity and the quantum efficiency are much higher in the ultraviolet range than in the visible range, and the peak values are around 360nm. Photocurrent transients show that the detector has a large photocurrent with the peak value of 2.8mA, and a slow photoresponse with a rise time of 5min and a decay time of 7min. The response curve of the detector is fitted well with exponential curve. The large photocurrent should result from the both effects of the accumulation of conduction electrons and the d...

2006-01-01

235

Particle identification for heavy ions in a time-of-flight spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A time-of-flight (TOF) spectrometer has been constructed at the JAERI 20 MV tandem accelerator facility. A position-sensitive start detector, which consists of a thin carbon foil, microchannel plates and a resistive plate, was developed for the TOF measurements through the spectrometer. The time and position resolutions obtained were 120 ps and 0.3 mm for ..cap alpha.. particles from /sup 241/Am, respectively. A two-dimensional position-sensitive detector was also developed to measure the solid angle of the spectrometer and the maximum solid angle obtained was 9.5 msr. As a particle detector a Bragg curve ionization chamber was developed. From the Bragg curves of heavy ions in the detector, energies, ranges and Bragg curve peaks were measured and used for particle identification. The resolving power Z/..delta..Z of the atomic number was about 50.

1982-05-01

236

PERFORMANCE-LIMITING DEFECTS IN CDZNTE DETECTORS.  

Energy Technology Data Exchange (ETDEWEB)

We studied the effects of small, <20 {micro}m, Te inclusions on the energy resolution of CdZnTe gamma-ray detectors using a highly collimated X-ray beam and gamma-rays, and modeled them via a simplified geometrical approach. Previous reports demonstrated that Te inclusions of about a few microns in diameter degraded the charge-transport properties and uniformity of CdZnTe detectors. The goal of this work was to understand the extent to which randomly distributed Te-rich inclusions affect the energy resolution of CZT detectors, and to define new steps to overcome their deleterious effects. We used a phenomenological model, which depends on several adjustable parameters, to reproduce the experimentally measured effects of inclusions on energy resolution. We also were able to hound the materials-related problem and predict the enhancement in performance expected by reducing the size and number of Te inclusions within ...

2006-10-29

237

Overview of the recent activities of the RD50 collaboration on radiation hardening of semiconductor detectors for the sLHC  

International Nuclear Information System (INIS)

The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1 MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.

2009-01-01

238

Overview of the recent activities of the RD50 collaboration on radiation hardening of semiconductor detectors for the sLHC  

British Library Electronic Table of Contents (United Kingdom)

The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.

2009-01-01

239

Optimal detector deployment for the CANDU-600 pressurized heavy water reactor  

Science.gov (United States)

An optimal deployment pattern of flux mapping detectors for a Canada uranium-deuterium (CANDU)-600 pressurized heavy water reactor (PHWR) is determined by obtaining an optimal feedback relationship between flux measurements and zone controllers. The reactor core is modeled with a time-dependent two-group, two-dimensional diffusion equation, and flux perturbation are expressed by model expansions. The modal expansion coefficients are used as elements of the state vector representing the system dynamics. An optimal feedback matrix connecting the flux measurement vector to the control vector is derived by minimizing a quadratic performance index involving both the state and control vectors. We obtain the detector effectiveness in terms of the optimal feedback matrix and determine optimal detector locations for the Wolsung Unit 1 reactor in Korea. We have tested the methodology through evaluation of flux maps generated through ...

1992-01-01

240

Mass dependence of the signal peak height of a Bragg-curve ionization chamber  

Energy Technology Data Exchange (ETDEWEB)

The Bragg-curve detector of the parallel plate ionization chamber type generates a signal that is a distorted replica of the original Bragg-curve. In result of this distortion, the signal peak height is not only a function of the atomic number of the heavy ion, as it is often stated, but also of the particle mass. This mass effect was studied with the aid of computer simulation, and it was found to be dependent on the Frisch grid to anode gap width and on the detector gas. The charge resolution of the detector is affected very significantly by this mass dependence of the signal peak height. Therefore, a careful selection of the detector gas and the grid to anode gap width is necessary, if good charge resolution over a wide range of heavy ions is required.

1985-01-01

241

Linewidth-broadened Fabry-Perot cavities within future gravitational wave detectors  

International Nuclear Information System (INIS)

The bandwidth of LIGO-like terrestrial interferometric gravitational wave detectors is set by the pole of the Fabry-Perot cavities within the arms of the Michelson interferometer. This constraint arises because the gain of gravitational wave-induced signal sidebands is limited to frequencies within the linewidth of the cavities. The nature of standard Fabry-Perot cavities is such that one cannot independently adjust for increased gain without suffering a loss of bandwidth. If these quantities could be decoupled, the resulting improvement in bandwidth may lead to viable high frequency detectors. A pair of anti-parallel diffraction gratings within a Fabry-Perot cavity can increase the bandwidth of a LIGO-scale detector by a factor of #approx#1000.

2004-03-07

242

LAMBDA - IRAS Faint Source Survey Plates - LAMBDA - NASA  

Science.gov (United States)

Apr 18, 2008 ... The FSS was produced by point-source filtering the individual detector data ... a 1-sigma noise map; and a coverage map giving the count of ...

243

Intercomparison of Retrospective Radon Detectors  

Energy Technology Data Exchange (ETDEWEB)

We performed both a laboratory and field intercomparison of two novel glass-based retrospective radon detectors previously used in major radon case-control studies performed in Missouri and Iowa. The new detectors estimate retrospective residential radon exposure from the accumulation of a long-lived radon decay product, Pb-210, in glass. The detectors use track registration material in direct contact with glass surfaces to measure the alpha emission of a Pb-210 decay product, Po-210. The detector's track density generation rate (tracks cm{sup -2} hr{sup -1}) is proportional to the surface alpha activity. In the absence of other strong sources of alpha emission in the glass, the implanted surface alpha activity should be proportional to the accumulated Po-210 and hence, the cumulative radon gas exposure. The goals of the intercomparison were to: (1) perform collocated measurements using two ...

1998-11-01

244

Developement of the method for realization of spectral irradiance scale featuring system of spectral comparisons  

Energy Technology Data Exchange (ETDEWEB)

Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is ...

2010-10-15

245

Developement of the method for realization of spectral irradiance scale featuring system of spectral comparisons  

International Nuclear Information System (INIS)

Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is ...

2010-10-01

246

Determination of Proper Peaking Time for Ultra Lege detector at Medium Energies  

International Nuclear Information System (INIS)

Reducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the optimum peaking time for particular detector systems is important. For this purpose, pure Se and Zn elements were excited by 59.5 keV ?-rays from a 50 mCi 241Am annular radioactive source in this study. The characteristic x-rays emitted from pure Se and Zn elements were detected by using an ultra low energy Ge (Ultra-LEGe) detector connecting Tennelec TC 244 spectroscopy amplifier at different peaking time modes. Overall pulse widths were determined by HM 203-7 oscilloscope connecting amplifier. The proper peaking time for ultra low energy germanium detector (Ultra-LEGe) is determined about 4 ?s.

2008-08-25

247

DESIGN, IMPLEMENTATION AND TESTING OF ... - LAMBDA - NASA  

Science.gov (United States)

FIG. 4. Power Spectral Density of the MAP W11 radiometer. The red and black traces are the power spectral density measurements of the two detectors on the ...

248

Conceptual Design of a Support Structure and an Assemble of Detectors Inside a Large Solenoid  

CERN Document Server

In this note we describe a support structure which will hold detector systems (ITS, TPC, TOF) inside the large solenoid. An overall view of ALICE detector is shown on Fig.1. The support structure consists of 2 rings which fixed to an iron yoke and spokes which connect TPC and TOF to these rings. The ITS is connected by spokes to TPC end caps. Between coils there are 7cm spacings which will allow to fix rings to the yoke this support structure will allow to assemble ITS, TPC and TOF together (Fig.2) somewhere on the surface and then transport to the pit and install in the magnet. Two rings (1) are connected with four bars (2). On the bottom bars there are rolls (3) which will allow smoothly insert detectors into the magnet. Spokes (4) are uniformly distributed.

1993-01-01

249

Comparison of effectiveness of three radon detectors (LR115, CR39 and silicon diode pin) placed in a cylindrical device -theory and experimental techniques  

Energy Technology Data Exchange (ETDEWEB)

Researchers at the Laboratory of Nuclear Microanalysis in Besancon (France) are developing and improving radon measurements in order to detect and analyse, more precisely radon emanation anomalies in both fields of Earth Sciences and Radioprotection. In order to characterize radon emanation, two complementary techniques are developed; continuous measurement through a portable proportional counter and passive measurements by nuclear track detectors for both fieldwork and laboratory analysis. A mathematical model is being devised to interpret the nuclear track detector response. This model is performed according to the device characteristics: type of detectors, shape and size of cells and whether a membrane is used or not. In addition to the theoritical study, experimental radon concentration measurements will be reported. (author).

1993-12-31

250

Comparison of effectiveness of three radon detectors (LR115, CR39 and silicon diode pin) placed in a cylindrical device -theory and experimental techniques  

International Nuclear Information System (INIS)

Researchers at the Laboratory of Nuclear Microanalysis in Besancon (France) are developing and improving radon measurements in order to detect and analyse, more precisely radon emanation anomalies in both fields of Earth Sciences and Radioprotection. In order to characterize radon emanation, two complementary techniques are developed; continuous measurement through a portable proportional counter and passive measurements by nuclear track detectors for both fieldwork and laboratory analysis. A mathematical model is being devised to interpret the nuclear track detector response. This model is performed according to the device characteristics: type of detectors, shape and size of cells and whether a membrane is used or not. In addition to the theoritical study, experimental radon concentration measurements will be reported. (author).

253

Annihilation of antiprotons in light nuclei  

CERN Document Server

CR-39 detectors have been exposed to a 5.9-MeV antiproton beam using the low energy antiproton ring (LEAR) facility at CERN. At this energy, tracks of antiprotons appear in a CR-39 detector after 135 min of etching in 6 M NaOH at 70C. Fluence of the antiproton beam has been determined using track density. We have also found tracks in the etched CR-39 detector at different depths (250-500 mum). These tracks have resulted from the annihilation of antiprotons with the constituents (H, C and O) of the CR-39 detector. The goal of the experiment is to develop a simple and low-cost method to study properties of antiparticles and those formed after annihilation of these particles with the target matter.

2006-01-01

254

AeroSpace Information for a Changing World - NASA Technical ...  

Science.gov (United States)

Mar 1, 2011 ... Currently there is no compact, portable and real time neutron detector instrumentation available for use inside spacecraft or on planetary ...

255
256

A Quantum-Enhanced Prototype Gravitational-Wave Detector  

CERN Document Server

The quantum nature of the electromagnetic field imposes a fundamental limit on the sensitivity of optical precision measurements such as spectroscopy, microscopy, and interferometry. The so-called quantum limit is set by the zero-point fluctuations of the electromagnetic field, which constrain the precision with which optical signals can be measured. In the world of precision measurement, laser-interferometric gravitational wave (GW) detectors are the most sensitive position meters ever operated, capable of measuring distance changes on the order of 10^-18 m RMS over kilometer separations caused by GWs from astronomical sources. The sensitivity of currently operational and future GW detectors is limited by quantum optical noise. Here we demonstrate a 44% improvement in displacement sensitivity of a prototype GW detector with suspended quasi-free mirrors at frequencies where the sensitivity is shot-noise-limited, by ...

2008-01-01

257

8 - NASA Technical Report Server (NTRS)  

Science.gov (United States)

feature similar to the face detection in Intel's OpenCV library, implement it in Matlab code, and test the performance of the new ROI detector against the ...

258

Study on reactivity measurement by the Feynman-#alpha# method  

International Nuclear Information System (INIS)

The Feynman-#alpha# method was applied to measurement of reactivity and the ability of this method for a real-time reactivity monitoring system was assessed. In the experiment, all measured data by BF_3 detectors were stored in a multi-channel scaler controlled by a personal computer, and they were analyzed to obtain prompt neutron decay constant (#alpha#) and reactivity with consideration of dead time of detector. It was found that #alpha# could be obtained almost in a real-time even for both positive and negative reactivities by the present experimental technique. (author).

1996-09-01

259

Si(111)/Gd: A fast and high-resolution thermal neutron detector  

Energy Technology Data Exchange (ETDEWEB)

Recent developments in design and production of thermal neutron detectors based on a crystalline Si diode coupled to a Gd converter are reviewed. The most significant results of neutron test measurements carried out on prototype systems and pointing out the performances of the device are reported. Progress through various detection schemes and technological solutions for the production of a real time neutron counter for routine operation are outlined.

1998-07-01

260

Self-filling and self-purging apparatus for detecting spontaneous radiation from substances in fluids  

Energy Technology Data Exchange (ETDEWEB)

Disclosed herein is a radiation detector providing for the in situ automatic sampling of fluids containing substances emitting radiation, especially Cerenkov radiation. The detector permits sampling within well casings and is self-purging such that no additional provisions must be established for the storage and disposal of contaminated fluids.

1993-01-01

261

Research in experimental elementary particle physics. A proposal to the U.S. Department of Energy  

Energy Technology Data Exchange (ETDEWEB)

We report on the activities of the High Energy Physics Group at the University of Texas at Arlington for the period 1994-95. We propose the continuation of the research program for 1996-98 with strong participation in the detector upgrade and physics analysis work for the D0 Experiment at Fermilab, prototyping and pre-production studies for the muon and calorimeter systems for the ATLAS Experiment at CERN, and detector development and simulation studies for the PP2PP Experiment at Brookhaven.

1995-04-13

262

Radon concentration measurements in the soil  

International Nuclear Information System (INIS)

Radon concentration measurement in the ground can be used for the prospecting for uranium and earthquake prediction. Some results of radon concentration measurement in the soil are presented here. The moisture condensation at the detector surface can affect on the detection efficiency. Due to this problem we tested a few filter papers on water permeability. The ratio of track densities on solid state nuclear track detector (SSNTD) in the open and the closed diffusion chamber is also determined. (author)

263

Proposed high-resolution vertex detector using superconductive thin strips  

Energy Technology Data Exchange (ETDEWEB)

The possibility of fabricating a superconductive vertex detector is discussed on the basis of a preliminary experiment. The experiment has shown that an indium strip 15 mm long, 20 ..mu..m wide and 0.1 ..mu..m thick is changed from the superconductive state to the normal state when struck by a single 5.4 MeV alpha particle.

1984-06-01

264

Portable real time neutron spectrometry II  

International Nuclear Information System (INIS)

We describe the continued development of a portable, real-time neutron spectrometer. The spectrometer is composed of two distinct detector systems: a Helium 3 gas filled proportional counter for the lower neutron energy interval between 20 KeV and 2 MeV and a bulk silicon solid state detector for the higher energy interval between 2 MeV and 500 MeV. Modeling and experimental results with mono-energetic neutron beams are reported.

2000-01-19

265

Portable real time neutron spectrometry  

International Nuclear Information System (INIS)

We describe the early stage of development of an engineering model portable, real-time neutron spectrometer. Several systems of two distinct detector types, a helium 3 gas filled proportional counter and a bulk silicon solid state detector, will be necessary to cover the energy range from thermal to 500 MeV. The advantages and disadvantages of using a moderator were investigated experimentally.

1999-01-22

266

Performance of the transition radiation detector in D{Phi}  

Energy Technology Data Exchange (ETDEWEB)

The transition radiation detector (TRD) for the D{Phi} experiment is currently in operation at Fermilab. Transition radiation production, which has been clearly observed in the collider data, makes the TRD a valuable tool to discriminate electrons and hadrons. We describe an algorithm based on the truncated energy, and illustrate its use for top signal and background. (authors). 7 refs., 6 figs., 2 tabs.

1994-12-31

267

Performance of a large Bragg-curve spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/..delta..Z=80 have been achieved for eleastically scattered /sup 58/Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments.

1987-04-01

268

Performance of a large Bragg-curve spectrometer  

International Nuclear Information System (INIS)

A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/#DELTA#Z=80 have been achieved for eleastically scattered "5"8Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments. (orig.).

269

Near-Core and In-Core Neutron Radiation Monitors for Real Time Neutron Flux Monitoring and Reactor Power Level Measurements  

Energy Technology Data Exchange (ETDEWEB)

MPFDs are a new class of detectors that utilize properties from existing radiation detector designs. A majority of these characteristics come from fission chamber designs. These include radiation hardness, gamma-ray background insensitivity, and large signal output.

2006-06-12

270

Multi-spectral schottky barrier infrared radiation detection array  

Energy Technology Data Exchange (ETDEWEB)

A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.

1983-12-27

271

Multi-spectral schottky barrier infrared radiation detection array  

International Nuclear Information System (INIS)

A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.

272

Interaction region layout of the VLEPP based photon linear collider with ultimate luminosity  

Energy Technology Data Exchange (ETDEWEB)

In the present paper, a possible interaction region layout of the VLEPP based Photon Linear Collider (PLC) with ultimate luminosity is discussed. In order to remove spent electron beams, the crab-crossing scheme is used. The detector is protected from produced pairs and secondary particles by means of the detector magnetic field and a shielding mask. ((orig.)).

1995-02-01

273

Gamma ray detecting device using dislocation-free crystal  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a {gamma}-ray detector. It comprises: a dislocation-free single crystal having an input surface and a transmission surface at opposite ends thereof; an active shield surrounding the crystal and functioning as an anticoincidence counter; and {gamma}-ray detector means disposed adjacent the transmission surface of the crystal for receiving and detecting {gamma}-rays of a predetermined wavelength incident on the input surface of the crystal at a specific Bragg angle and transmitted through the crystal.

1991-04-30

274

GaAs detector optimization for different medical imaging applications  

International Nuclear Information System (INIS)

We have investigated the detection performance of GaAs detectors made with different thickness and contact geometries. A comparison is made between these detection capabilities and the imaging requirements for the following medical applications: digital mammography, digital chest radiography and nuclear medicine. Experimental results and preliminary images are presented and discussed. (author)

1999-09-11

275

First tests of "bulk" MICROMEGAS with resistive cathode mesh  

CERN Document Server

We present the first results from tests of a MICROMEGAS detector manufactured using the so-called "bulk" technology and having a resistive cathode mesh instead of the conventional metallic one. This detector operates as usual MICROMEGAS, but in the case of sparks, which may appear at high gas gains, the resistive mesh reduces their current and makes the sparks harmless. This approach could be complementary to the ongoing efforts of various groups to develop spark-protected MICROMEGAS with resistive anode planes.

2010-01-01

276

Explosives detection: the problem and prospects  

Energy Technology Data Exchange (ETDEWEB)

The history of explosives vapor detection includes almost every detection strategy known to man. Initial attempts to utilize these techniques were dismal failures. However, with the development of the Electron Capture Detector (ECD), the first promising detection of explosives vapors became possible. The present commercial explosives detectors detect the higher vapor pressure materials but not the whole spectrum. This paper describes the basic properties of explosives molecules and our research to utilize these properties for increased detection sensitivity.

1984-01-01

277

Direct gamma-spectrometry of surface activity with IGC-30 HPGe detector  

International Nuclear Information System (INIS)

The IGC-30 HPGe detector with MCA 'CANBERRA-10 PLUS' allows to determine surface contamination of areas of any type with a minimum error in radius 8-10 m, at a 'uniform' contamination. A modification of the CANBERRA hardware and software is described allowing determination of both the activity of a possible 'radioactive spot' and the activity of the whole observed surface. (author).

1993-12-02

278

Development of a real-time, neutron and gamma dosimeter  

Energy Technology Data Exchange (ETDEWEB)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-07-01

279

Development of a real-time, neutron and gamma dosimeter  

International Nuclear Information System (INIS)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-06-10

280

Determination of reactor kinetic parameters in a two-core reactor  

Energy Technology Data Exchange (ETDEWEB)

The kinetic parameters, ..cap alpha.. the coupling coefficient and tau-bar the mean neutron transit time have been determined using a reactor oscillator on the coupled-core of the Queen Mary College research reactor. By using correlation techniques it has proved possible to use detectors small enough to be inserted in the fuel tanks. It is shown that the simplified Baldwin model with one-group diffusion theory is inadequate to describe the kinetic behaviour and the experimentally-determined parameters are dependent upon the positioning of the detectors.

1982-01-01

281

Detector questions for a gamma-gamma collider  

Energy Technology Data Exchange (ETDEWEB)

The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).

1995-02-01

282

Detector questions for a gamma-gamma collider  

International Nuclear Information System (INIS)

The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).

283

Detection device for high explosives  

Energy Technology Data Exchange (ETDEWEB)

A portable fiber optic detector that senses the presence of specific target chemicals by electrostatically attracting the target chemical to an aromatic compound coating on an optical fiber. Attaching the target chemical to the coated fiber reduces the fluorescence so that a photon sensing detector records the reduced light level and activates an appropriate alarm or indicator.

1992-01-01

284

Ceramic inspection system  

Science.gov (United States)

A system for inspecting a ceramic component. The ceramic component is positioned on a first rotary table. The first rotary table rotates the ceramic component. Light is directed toward the first rotary table and the rotating ceramic component. A detector is located on a second rotary table. The second rotary table is operably connected to the first rotary table and the rotating ceramic component. The second rotary table is used to move the detector at an angle to the first rotary table and the rotating ceramic component.

2006-05-16

285

CPA simulator: A software tool to simulate nuclear front-end circuit response  

International Nuclear Information System (INIS)

A computer program 'CPA simulator' has been designed to simulate the response parameters of a typical charge preamplifier (CPA) used in nuclear front-end electronics. The response parameters are studied considering three common connection methods between the detector and the CPA. The simulator predicts and illustrates the role and influence of the different components of the CPA and detector circuits.

2010-12-21

286

Assessment of detector sensitivity and uniformity during SPECT rotation  

International Nuclear Information System (INIS)

The purpose of this research was to: a) evaluate variations in sensitivity and uniformity of SPECT detectors during 360"0 rotation, b) explore the causes of the variations and c) to discuss a correction procedure. A flood source consisting of a lucite disc 47.7 cm in diameter containing 3 microcuries of Co-57 was constructed. This source can be firmly attached to the uncollimated detector guaranteeing no detector-source geometry change during rotation. Four different SPECT cameras were tested. Measurements were obtained at 45"0 intervals throughout a 360"0 rotation, and repeated in 3 different orientations with respect to the earth's magnetic field. In one camera the effects of the direction and strength of induced magnetic fields were studied. All detectors showed cyclic rotational variations in sensitivity; in three cameras 6%, in one 3%. The amplitude and phase of the sensitivity variation curves and ...

1984-06-05

287

Applications of Bonner sphere detectors in neutron field dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)

1983-09-01

288

An imaging. gamma. -ray detector with scatter rejection for beam position control in radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

An imaging detector for {gamma}-rays ({approx equal}1 MeV) based on minicell MWPCs with converters and a position resolution of {Delta}x=0.5 mm has been developed and tested. Very high rate capability (>10{sup 8}/cm{sup 2} s) and a special readout for suppression of scattered radiation are implemented allowing to enhance the measured contrast. The relevant physical processes are discussed and first pictures are presented. (orig.).

1991-12-01

289

Advanced radiation detector development: Advanced semiconductor detector development: Development of a oom-temperature, gamma ray detector using gallium arsenide to develop an electrode detector  

Energy Technology Data Exchange (ETDEWEB)

The advanced detector development project at the University of Michigan has completed the first full year of its current funding. Our general goals are the development of radiation detectors and spectrometers that are capable of portable room temperature operation. Over the past 12 months, we have worked primarily in the development of semiconductor spectrometers with {open_quotes}single carrier{close_quotes} response that offer the promise of room temperature operation and good energy resolution in gamma ray spectroscopy. We have also begun a small scale effort at investigating the properties of a small non-spectroscopic detector system with directional characteristics that will allow identification of the approximate direction in which gamma rays are incident. These activities have made use of the extensive clean room facilities at the University of Michigan for semiconductor device fabrication, and also the radiation ...

1995-11-01

290

A solution for solid state detector and preamplifier protection, during HV application and removal transition periods  

International Nuclear Information System (INIS)

Surface barrier detectors may be damaged, because of microplasma breakdown, in rapid application of bias voltage. The high performance FETs of very low noise preamplifiers may also be damaged by rapid changes of the bias voltage. The electronic device described permits the gradual application and removal of the bias voltage, without any influence on the power supply specification. (Auth.).

291

A large-acceptance Bragg curve spectrometer with a longitudinal electric field and a segmented anode  

Energy Technology Data Exchange (ETDEWEB)

A large-acceptance Bragg curve spectrometer with a longitudinal electron collection field and a segmented anode has been constructed and tested. The effects on the charge resolution of the entrance angle and entrance position of the incident particle have been studied. Simulations have been done in order to isolate the contribution to the overall detector performance of the signal-shaping electronics from that of the intrinsic design of the detector. ((orig.))

1994-07-15

292

Recent Progress in CdTe and CdZnTe Detectors  

CERN Document Server

Cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) have been regarded as promising semiconductor materials for hard X-ray and Gamma-ray detection. The high atomic number of the materials (Z_{Cd} =48, Z_{Te} =52) gives a high quantum efficiency in comparison with Si. The large band-gap energy (Eg ~ 1.5 eV) allows us to operate the detector at room temperature. However, a considerable amount of charge loss in these detectors produces a reduced energy resolution. This problem arises due to the low mobility and short lifetime of holes. Recently, significant improvements have been achieved to improve the spectral properties based on the advances in the production of crystals and in the design of electrodes. In this overview talk, we summarize (1) advantages and disadvantages of CdTe and CdZnTe semiconductor detectors and (2) technique for improving energy resolution and photopeak efficiencies. Applications of these ...

2001-01-01

293

GaAs Blocked-Impurity-Band Detectors for Far-Infrared Astronomy  

Energy Technology Data Exchange (ETDEWEB)

High-purity and doped GaAs films have been grown by Liquid-phase epitaxy (LPE) for development of a blocked impurity band (BIB) detector for far-infrared radiation. The film growth process developed has resulted in the capability to grow GaAs with a net active impurity concentration below 1 x 10{sup 13} cm{sup -3}, ideal for the blocking layer of the BIB detector. The growth of n-type LPE GaAs films with donor concentrations below the metal-insulator transition, as required for the absorbing layer of a BIB detector, has been achieved. The control of the donor concentration, however, was found to be insufficient for detector production. The growth by LPE of a high-purity film onto a commercially grown vapor-phase epitaxial (VPE) n-type GaAs doped absorbing layer resulted in a BIB device that showed a significant reduction in the low-temperature dark current compared to the absorbing layer only. Extended ...

2004-12-21

294

Design of a GaAs X-ray imaging sensor with integrated HEMT readout circuitry  

CERN Document Server

A new monolithic semi-insulating (SI) GaAs sensor design for X-ray imaging applications between 10-100keV has been proposed. Monolithic pixel detectors offer a number of advantages over hybrid bump-bonded detectors, such as high device yield, low costs and are easier to produce large scale arrays. In this thesis, an investigation is made of the use of a SI GaAs wafer as both a detector element and substrate for the epitaxially grown High Electron Mobility Transistors (HEMTs). The design of the HEMT transistors, optimised for this application, were produced with the aid of the Silvaco 'Virtual Wafer Fab' simulation package. It was determined that the device characteristics would consist of a small positive threshold voltage, a low off-state drain current and high transconductance. The final HEMT transistor design, that would be integrated to a pixel detector, had a threshold voltage of 0.17V, an ...

2002-01-01

295

Design and implementation of the BESIII detector-control system  

Energy Technology Data Exchange (ETDEWEB)

In the upgrade project of the Beijing Electron-Positron Collider (BEPCII), a novel Detector-Control System (DCS) for the Beijing Spectrometer (BESIII) has been built and started its successful operation for the BESIII Commissioning. The main task of the DCS is to monitor and control the status of the BESIII detector and to guarantee a safe operation of the detector. The DCS must provide a uniform and coherent interface to detector operators even though there are a large number of distributed I/O channels from a large variety of equipments. For this reason, the DCS is hierarchically organized and divided into three layers: front-end layer (FEL), local control layer (LCL) and global control layer (GCL). In the FEL, devices ranging from simple sensors up to complex computer-based devices like embedded systems and programmable logical controllers (PLC) are utilized. A LabVIEW-based software framework has ...

2008-07-21

296

Transuranic separation using organophophorus extractants adsorbed onto superparamagnetic carriers.  

Energy Technology Data Exchange (ETDEWEB)

Polymeric coated ferromagnetic carriers with an absorbed layer of octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO) diluted by tributyl phosphate (TBP) are being evaluated for application in the separation and the recovery of low concentrations of americium, plutonium, and uranium from nuclear waste solutions. Due to their chemical nature, these extractants selectively complex americium and plutonium contaminants onto the particles and the complexed particles can be recovered from the solution using a magnet. Physical and chemical characterization of the extractant-absorbed particles were performed by gamma and liquid scintillation counting, scanning electron microscopic (SEM) micrograph, and other physical measurements. Plutonium, americium, and uranium separations have been performed at various HNO{sub 3} and HCl concentrations. Parameters were studied to determine the limitations and capacity of the process. The status of the chemistry and ...

1998-10-07

297

Study of the light yield of LuAP:Ce scintillating crystals  

Energy Technology Data Exchange (ETDEWEB)

We have obtained optically clear samples of LuAP:Ce from the Institute of Physical Research, Ashtarak, Armenia, measuring up to 5x5x40 mm{sup 3}. The photo electron yield for a number of theses samples was measured with a Philips XP2020Q photomultiplier tube, and 556 photo electrons per MeV was obtained for the best samples. This is comparable to what is obtained from BGO crystals under the same condition, but a factor of 5 less than what is obtained with an LSO sample of similar dimensions. The light in LuAP:Ce increases with cerium concentration between 0.13 and 0.47%.

1996-12-31

298

Standardisation of "2"1"0Pb by Cerenkov counting  

International Nuclear Information System (INIS)

A standard of "2"1"0Pb in solution was produced at the National Physical Laboratory by a novel technique combining Cerenkov counting with the established liquid scintillation efficiency tracing technique known as the CIEMAT/NIST method. Coincidence counting was applied in order to validate the measurements and the activity concentrations of the solution determined with each technique are shown to be in agreement. Radiochemical separation of the "2"1"0Pb from its daughters was also necessary and the scheme for the separation is described. After performing this two-stage standardisation, the uncertainty was successfully lowered to 0.66% (k=1). This uncertainty is approximately a factor of four lower than previously achieved at NPL by the classical method of standardisation of radionuclides, i.e. coincidence counting.

2011-05-01

299

PET/MRI hybrid imaging: devices and initial results  

British Library Electronic Table of Contents (United Kingdom)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...

2008-01-01

300

Multi-GeV electron spectrometer  

Energy Technology Data Exchange (ETDEWEB)

The advance in laser-plasma acceleration techniques pushes the regime of the resulting accelerated particles to higher energies and intensities. In particular the upcoming experiments with the FLAME laser at LNF will enter the GeV regime with almost 1nC of electrons. From the current status of understanding of the acceleration mechanism, relatively large angular and energy spreads are expected. There is therefore the need to develop a device capable to measure the energy of electrons over three orders of magnitude (few MeV to few GeV) under still unknown angular divergences. Within the PlasmonX experiment at LNF a spectrometer is being constructed to perform these measurements. It is made of an electro-magnet and a screen made of scintillating fibers for the measurement of the trajectories of the particles. The large range of operation, the huge number of particles and the need to focus the divergence present unprecedented challenges in the design and construction ...

2010-11-11

301

Improvement of a radiochemical separation for selenium 79: Applications to effluents and nuclear wastes.  

Science.gov (United States)

Selenium 79 is a beta emitter produced from (235)U fission and is one of the long half-life radionuclides of interest in nuclear waste disposal problematic because of its potential migration capacity to the surface environment. Measurement of (79)Se is particularly difficult due to its low activity in waste matrices (about 10(-3)Bqg(-1)). A radiochemical procedure based on ion exchange separations was already described in a previous paper. This work presents different applications of the radiochemical separation to waste samples and an improvement of this procedure, including a selective extraction of selenium as diethylselenium in an organic solvent followed by a re-extraction in aqueous medium. This additional step allows the decontamination factor to be increased with the aim of counting (79)Se by liquid scintillation counting. PMID:19071740

2007-01-14

302

Implantation of an electronic system for real time neutron graphic images acquisition at the IPEN/CNEN Argonaut reactor; Implantacao de um sistema eletronico para aquisicao de imagens neutrongraficas em tempo real no reator Argonauta do IEN/CNEN  

Energy Technology Data Exchange (ETDEWEB)

The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)

2004-04-15

303

Electronic structures of luminescence centers in pure and defective scintillation crystals AWO4 (A = Pb, Cd, Zn)  

International Nuclear Information System (INIS)

The electronic structures of the set of molecular clusters of dielectric oxide crystals AWO4 (A = Pb, Cd, Zn), the sizes of which increase sequentially are ab-initio calculated by the Restricted Hartree-Fock (RHF) method. The results of calculations of molecular orbitals and energy dependences of partial densities of electronic states of different clusters are compared each to other and to experimental data. It is found that calculated electronic structures of the tungstate groups and cations which are surrounded in cluster by certain number of the nearest neighbor atoms of the crystals quite well represent the experimentally obtained value of the forbidden gap of corresponding AWO4 crystal. (authors)

304

A tomography system at the thermal neutron column of the ENEA Casaccia TRIGA reactor  

Energy Technology Data Exchange (ETDEWEB)

The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10{sup 6} n/cm{sup 2} s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)

2002-07-01

305

A tomography system at the thermal neutron column of the ENEA Casaccia TRIGA reactor  

International Nuclear Information System (INIS)

The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10"6 n/cm"2 s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)

306

Gamma-ray pulse height spectrum analysis on systems with multiple Ge detectors using a spectrum summing  

Energy Technology Data Exchange (ETDEWEB)

A technique has been developed at the Idaho National Engineering Laboratory to sum high resolution gamma-ray pulse spectra from systems with multiple Ge detectors. Lockheed Martin Idaho Technologies Company operates a multi-detector spectrometer configuration at the Stored Waste Examination Pilot Plant facility which is used to characterize the radio nuclide contents in waste drums destined for shipment to Waste Isolation Pilot Plant. This summing technique was developed to increase the sensitivity of the system, reduce the count times required to properly quantify the radionuclides and provide a more consistent methodology for combining data collected from multiple detectors. In spectrometer systems with multiple detectors looking at non homogenous waste forms it is often difficult to combine individual spectrum analysis results from each detector to obtain a meaningful result for ...

1997-05-01

307

Use of primary electron counting for detection of ultrasoft x-rays with a low-pressure multistep gaseous detector  

International Nuclear Information System (INIS)

The use of primary electron counting techniques as an alternative to the more usual parallel plate avalanche chamber that has been employed in soft x-ray scattering experiments is being investigated at the National Synchrotron Light Source. The theoretical aspects of primary electron counting and motivation behind building a primary electron counting detector are described, as well as characteristics and future improvements of the device constructed at the NSLS. The detector consists of a low electric field drift region and a low pressure multistep avalanche region which can be operated with two or three stages of electron multiplication. The device has worked well in extensive tests as a simple parallel plate avalanche chamber, providing energy resolutions of 58% and 43% at 277 and 500 eV, respectively. Operated as a primary electron counter, preliminary results show an energy resolution of 38% at 500 eV.

308

Ultraviolet detectors based on ZnO films by thermal oxidation of Zn metallic films  

British Library Electronic Table of Contents (United Kingdom)

Metallic Zn films were deposited on glass substrates by electron-beam evaporation. ZnO films were synthesized by thermal oxidation of Zn metallic films in air. At the annealing temperature of 550 ?C, ZnO nanowires appeared on the surface, which mainly result from the decrease of oxidation rate. A ZnO ultraviolet photodetector was fabricated based on a metal-semiconductor-metal planar structure. The detector showed a large UV photoresponse with an increase of two orders of magnitude. It is concluded that promising UV detectors can be obtained on ZnO films by thermal oxidation of Zn metallic films. The ways of performing spectral response measurements for polycrystalline ZnO films are also discussed.

2008-01-01

309

Superconducting strip detectors as position sensitive particle detectors  

Energy Technology Data Exchange (ETDEWEB)

The feasibility of using of current-biased superconducting strips for radiation detection is investigated. Narrow Ta strips are exposed to 5.5 MeV [alpha]-particle radiation and the rise-time of the induced voltage pulses is measured as function of temperature and bias current. The rise-time of the voltage signal strongly depends on the site on the strip which is hit by the [alpha]-particle. In order to determine the spatial resolution of a superconducting strip detector, position-sensitive measurements were performed. The maximum lateral resolution estimated so far is 25[mu]m in a 7[mu]m wide, 340 nm thick and 0.6 mm long Ta-strip. (orig.)

1994-02-01

310

Status of combined point source search with neutrino telescopes IceCube and AMANDA  

Energy Technology Data Exchange (ETDEWEB)

In this talk, we summarize recent results obtained from the combined neutrino telescopes IceCube and AMANDA. The combined approach, including data taken from both detectors simultaneously, is compared to other analyses that are using IceCube only data. The main benefit of the combined detector is its improved performance at low energies, meaning energies below 1 TeV (close to the energy threshold of the detector). The discussion is focused on the search for extra-terrestrial neutrinos from candidate sources in our Galaxy. Using appropriate cuts, the sensitivity can be optimized for soft spectra neutrino sources. With the resulting data sample, several studies are performed: an unbinned Galactic Plane Scan and a Cygnus region analysis: the Multi Point Source analysis. The current status of these analyses is presented.

2010-07-01

311

Spatial distribution of IGC-30 Ge-detector's efficiency  

International Nuclear Information System (INIS)

The dependence of the efficiency of a coaxial IGC-30 Ge detector on the direction of gamma quanta entry, their energy and the distance from the source is examined. A set of point sources QCR-2 (Amersham, UK) has been used which is arranged consecutively in two perpendicular planes passing through the detector axis, at a distance of 0.1 - 1.3 m (pace 0.1) from its geometric centre for 16 different angles in every plane. Dependence curves of the efficiency on the angle of gamma-quanta hits are obtained for energies 60, 81, 122, 356, 662, 834, 1173 and 1332 keV. Changes in efficiency connected with spatial dividing ability are found out. Using the least squares' method the expected spatial distribution of efficiency is examined with a level of authenticity P > 0.9. The possible causes for the efficiency change and its possible effect on the measurements' precision are discussed. (author).

1993-12-02

312

Some considerations about future interferometric GW detectors  

International Nuclear Information System (INIS)

The two most important issues in designing future gravitational wave interferometric detectors are, in our opinion, thermal and optical noise. In this paper we discuss some approaches for reducing these noises. About thermal noise we show a possible cryogenic solution. About optical noise (namely, the combined effect of shot noise and radiation pressure noise) we show that it is possible to apply a recently proposed reduction strategy based on a 'quantum feedback' (Courty et al 2003 Phys. Rev. Lett. 90 083601; Courty et al 2003 Preprint gr-qc/0301068) to a full Fabry-Perot cavity. This can be seen as a further step towards the practical realization of a detector which is able to evade the standard quantum limit.

2004-03-07

313

Quartz fiber calorimetry and calorimeters  

CERN Document Server

Quartz fiber calorimetry is a technique the signal generation mechanism of which is based on the Cherenkov effect. In this article we try to give a comprehensive overview of the subject. We start with a general introduction to calorimetry where the basic elements that characterize the development of electromagnetic and hadronic showers are discussed. Then we describe in detail the operation principle and the properties of calorimeters equipped with quartz fibers. The main advantages of this type of calorimeters are the radiation hardness, the fast response and the compact detector dimensions, features that derive from the quartz material and the specific mechanism of operation. A section is devoted to presenting the quartz fiber calorimeters that have been built or planned to in various experiments to operate as centrality detectors, trigger detectors, luminosity monitors or general purpose very forward calorimeters.

2004-01-01

314

Plane electrode device for multiwire detector for ionizing radiations  

International Nuclear Information System (INIS)

A multiwire proportional counter type detector with thin slits instead of wires is presented. It can detect either charged particles (positive or negative) or radiation. The detector can be used as a counter or as an image converter. In radiography, it can replace photographic film or TV camera systems. It can also be used to measure particle or radiation energy. The slits which replace wires in the anode are introduced between two parallel microstrip conductors with different potentials. A quasi-polar electric field is produced between these strips. To obtain high fields, the slits are extremely narrow. Microstrips less than a micron can be obtained, giving structural dimensions of a few microns, i.e., 100 times smaller than the spacing in a classic wire anode.

1986-07-01

315

Particle and X-ray damage in pn-CCDs  

Energy Technology Data Exchange (ETDEWEB)

The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.

2000-01-11

316

Multichannel radiometric inspection systems with half-tone visualization of radiation shadow images. 1. Mathematical model  

International Nuclear Information System (INIS)

A mathematical model of multichannel radiometric inspection system was developed, in which the measurement results are reproduced in the form of a half-tone image equivalent to the radiation image of the irradiated object. The model makes the following assumptions: the beam of radiation is fan-shaped; the object of inspection is scanned discretely; the focal spot of the source is rectangular; the apertures of the detector are round, and the detectors themselves are equidistant from the sources, aimed at it, and form a close-packed array; the signals from the detectors are processed according to a time scheme; and the measurement results are corrected in a computer for normalizing the gains of the channels of the system. The mathematical model can serve as the basis for developing a method of calculating the optimal parameters of a multichannel radiometric system with visualization of the radiation images. 14 refs., 2 figs.

317

Measurement of radon daughter product burden by TLD dosemeters  

International Nuclear Information System (INIS)

A miniature device is described for measuring integral potential alpha energy concentration of radon daughter products (Csub(Rn)) for personnel and stationary dosimetry. The measuring apparatus consists of an air sampler, filters and TLD detectors. CaSO_4:Dy-teflon pellets were used as the detectors which registrate #gamma# radiation as well. The TLD-effect dependence on the potential alpha energy, as well as the fading of the detectors at 20-60 deg C after 170 hrs operation are presentd. The fading up to 40 deg C has been found to be negligible. The dosimeter may be used to measure Csub(Rh) starting with the 10"5 MeVxh/1 threshold, the accuracy being not worse than +-30%.

318

Magnetic beam position monitor  

Energy Technology Data Exchange (ETDEWEB)

Many nondestructive beam position monitors are known. However, these devices can not be used for DC particle beam diagnostics. We investigated a method of beam diagnostics applicable for the operative control of DC high power e-beam inside closed waveguide. A design of the detector for determination of{open_quote} center of mass {close_quote} position of DC particle beam was developed. It was shown that the monitor can be used as a nondestructive method for the beam position control in resonators. Magnetic field of the particle beam outside a resonator is used. The detector consists of the steel yokes and magnetic field sensors. The sensors measure magnetic fluxes in the steel yokes fixed outside the resonator. When the particle beam changes its position, these magnetic fluxes also change. Beam displacement sensitivity of the monitor depends on the steel yoke dimensions. The detector sensitivity is equal to 1 Gauss/mm for ...

1995-12-31

319

Ion beam induced charge imaging of epitaxial GaN detectors  

Energy Technology Data Exchange (ETDEWEB)

We report the use of ion beam induced charge imaging to characterise the charge signal uniformity of epitaxial gallium nitride radiation detectors. The detectors were fabricated from 2 {mu}m thick semi-insulating gallium nitride, grown by MOCVD on a sapphire substrate. A carrier concentration of 1.4x10{sup 15} cm{sup -3} was measured using capacitance-voltage measurements. Ion beam induced charge imaging was carried out with a 2 MeV alpha particle beam focussed to a 3 {mu}m diameter and raster scanned across the device. The resulting ion beam images show excellent charge signal uniformity in this material with no evidence of material defects or polycrystalline structure on the micrometer length scale. No evidence of charge signal trapping was observed in these devices.

2004-09-21

320

Indoor radon concentration measurements in some Spanish houses and dwellings with plastic nuclear track detectors  

Energy Technology Data Exchange (ETDEWEB)

A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a {sup 241}Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).

1991-01-01

321

Indoor radon concentration measurements in some Spanish houses and dwellings with plastic nuclear track detectors  

International Nuclear Information System (INIS)

A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a "2"4"1Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).

322

Indoor and outdoor Radon concentration measurements in Sivas, Turkey, in comparison with geological setting  

British Library Electronic Table of Contents (United Kingdom)

Indoor and soil gas Radon (222Rn) concentration measurements were accomplished in two stages in Sivas, a central eastern city in Turkey. In the first stage, CR-39 passive nuclear track detectors supplied by the Turkish Atomic Energy Authority (TAEA) were placed in the selected houses throughout Sivas centrum in two seasons; summer and winter. Before the setup of detectors, a detailed questionnaire form was distributed to the inhabitants of selected houses to investigate construction parameters and properties of the houses, and living conditions of inhabitants. Detectors were collected back two months later and analysed at TAEA laboratories to obtain indoor 222Rn gas concentration values. In the second stage, soil gas 222Rn measurements were performed using an alphameter near the selected h...

2010-01-01

323

High Energy Neutrino Telescopes  

CERN Document Server

This paper presents a review of the history, motivation and current status of high energy neutrino telescopes. Many years after these detectors were first conceived, the operation of kilometer-cubed scale detectors is finally on the horizon at both the South Pole and in the Mediterranean Sea. These new detectors will perhaps provide us the first view of high energy astrophysical objects with a new messenger particle and provide us with our first real glimpse of the distant universe at energies above those accessible by gamma-ray instruments. Some of the topics that can be addressed by these new instruments include the origin of cosmic rays, the nature of dark matter, and the mechanisms at work in high energy astrophysical objects such as gamma-ray bursts, active galactic nuclei, pulsar wind nebula and supernova remnants.

2008-01-01

324

Feasibility study of the iterative x-ray phase retrieval algorithm  

International Nuclear Information System (INIS)

An iterative phase retrieval algorithm was previously investigated for in-line x-ray phase imaging. Through detailed theoretical analysis and computer simulations, we now discuss the limitations, robustness, and efficiency of the algorithm. The iterative algorithm was proved robust against imaging noise but sensitive to the variations of several system parameters. It is also efficient in terms of calculation time. It was shown that the algorithm can be applied to phase retrieval based on one phase-contrast image and one attenuation image, or two phase-contrast images; in both cases, the two images can be obtained either by one detector in two exposures, or by two detectors in only one exposure as in the dual-detector scheme.

2009-01-01

325

Cooling device for impurity removal device in thermonuclear devices  

International Nuclear Information System (INIS)

Purpose: To prevent structure material meltdown upon rupture of cooling pipeways in a impurity remover by preventing the coolants from flowing into the vacuum vessel while continuing the supply of coolants to other portions to be cooled. Constitution: Dual cooling pipeway systems are disposed to the neutralizing plates of the impurity remover. A rupture detector (pressure gage) is mounted to each of the cooling pipeways and flow rate control valves to be opened and closed by the signal from the detector are disposed to the upstream and downstream of the cooling pipeway. In this constitution if the cooling pipes should be ruptured, the coolant supply is stopped to the ruptured system in which the flow rate valve is closed by the signal from the rupture detector. However, since the coolant is kept to be supplied to the other system of the cooling pipeways, meltdown of the neutralizing plates can be prevented. (Kamimura, M.).

1983-08-26

326

Aging measurements of a TMAE-based photon detector for the HERA-B RICH  

CERN Document Server

We report on aging measurements of a photon detector candidate for the HERA-B RICH. The prototype, a proportional wire chamber operated with TMAE, was mounted on an argon filled test-beam RICH and was aged by UV light at rates we expect in HERA-B. We monitored gain and current continuously, and checked the chamber with Cherenkov photons at regular intervals. The number of detected photons/track (projected to 2.75 m C sub 4 F sub 1 sub 0 in HERA-B) dropped from 26 to 11 after two days of aging - well below the 20 required for pi/K separation. Based on these results, HERA-B decided to use multi-anode PMTs as photon detectors in the RICH.

1999-01-01

327

Absolute subcriticality measurement without calibration and detection efficiency dependence by the /sup 252/Cf source-driven noise method  

Energy Technology Data Exchange (ETDEWEB)

The /sup 252/Cf-source-driven noise analysis method determines the subcriticality of a system containing fissionable material from the ratio of cross power spectral densities between the detectors that detect particles from the fission process and between these detectors and an ionization chamber containing a spontaneously fissioning neutron source which provides neutrons to induce fission in the system. This method has two advantages: (1) a calibration is not required and thus subcriticality can be determined from measurements only on the subcritical system of interest, and (2) the subcriticality is independent of the type of detector or its efficiency. These properties of this technique are illustrated by measurements.

1984-01-01

328

A planar circular detector based on multiple point chemi- or bio-luminescent source within a coaxial cylindrical reactor  

British Library Electronic Table of Contents (United Kingdom)

An analytical method was proposed for calculating radiative fluxes incident on a planar circular detector from a volume multiple point chemi- or bio-luminescent source inside a coaxial cylindrical reactor. The method was designed for a cylindrical reactor when the surface reflections were neglected and when chemi- or bio-luminescence reaches a detector embedded in the same homogeneous optical medium as the point emitters of the volume multiple point source model. The radiative fluxes from arbitrarily distributed point emitters were expressed by one generalized quadruple-integral formula. Then some double- and single-integral formulas were obtained for calculating radiative fluxes from identically radiating point emitters uniformly distributed within the reactor. Selected results were compu...

2009-01-01

329

Real-time neutron radiography; Radiografia com neutrons em tempo-real  

Energy Technology Data Exchange (ETDEWEB)

The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the {gamma}-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10{sup 6}n/cm{sup 2}s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/{gamma} ratio {approx} 10{sup 6}n/cm{sup 2}mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame grabber and a computer. The device composed ...

2000-07-01

330

Real-time neutron radiography at Texas A and M University  

Energy Technology Data Exchange (ETDEWEB)

A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are used in place of the SIT camera. The computer digitizes the TV ...

1990-12-20

331

Real-time neutron radiography at Texas A and M University  

International Nuclear Information System (INIS)

A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are used in place of the SIT camera. The computer digitizes the TV ...

1990-12-01

332

Real-time neutron radiography  

International Nuclear Information System (INIS)

The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the #gamma#-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10"6n/cm"2s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/#gamma# ratio #approx# 10"6n/cm"2mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame grabber and a computer. The device composed by the ...

2000-01-01

333

Using Military Working Dog Teams (MWDTs) to Support Law ...  

Science.gov (United States)

... 4. Military Working Dogs iMWDs). As used in this Instruction refers to drug detector dogs only. 5. Military Working Doq Executive Agent M(WJDEMA. ...

1990-09-17

334

Use of solid state nuclear track detectors for radon concentration measurements indoors  

International Nuclear Information System (INIS)

An indoor radioactive survey is being conducted in an Italian district. Preliminary results identified a zone with significant radioactive levels, in which a new specific survey has been planned. In this paper attention is dedicated mainly to radon measurement technique and results.

335

The urine dipstick test useful to rule out infections. A meta-analysis of the accuracy  

UK PubMed Central (United Kingdom)

BackgroundMany studies have evaluated the accuracy of dipstick tests as rapid detectors of bacteriuria and urinary tract infections (UTI). The lack of an adequate explanation for...Full Text Available

336

The Development of a Neutral Particle Detector for Observations of the Thermosphere  

Science.gov (United States)

One of the least understood regions of the upper atmosphere is the thermosphere, principally due to the difficulty of making observations. The neutral atmosphere is known to be highly variable, and its composition and density varies by several orders of magnitude due to solar activity, diurnal cycles, latitude, geomagnetic activity, and gravity waves. In the past, most in-situ measurements of the neutral atmosphere have utilized detectors that are dependent on arrival angle and energy accommodation of incoming species, so that information related to nascent velocity distribution and reactive species abundances is often masked. This paper will review design concepts and laboratory tests related to the development of a novel open-ionizer, neutral particle detector for space environment measurements which can overcome these limitations. The sensor features a very large field-of-view suitable for sounding rocket missions. This time-of-flight ...

2006-12-01

337

Study of Stent Deployment Mechanics Using a High-Resolution X-ray Imaging Detector  

UK PubMed Central (United Kingdom)

To treat or prevent some of the 795,000 annual strokes in the U.S., self-expanding endo-vascular stents deployed under fluoroscopic image guidance are often used. Neuro-interventionalists need...Full Text Available

2011-03-01

338

Search for free quarks at PEP  

Energy Technology Data Exchange (ETDEWEB)

The results of a search for fractionally charged particles produced in e/sup +/e/sup -/ annihilation at 29 GeV/c/sup 2/ are discussed. Results from cosmic-ray searches for fractionally charged particles, tachyons, and massive particles using the same detector are also presented.

1982-01-01

339

Research in heavy-ion nuclear physics  

Energy Technology Data Exchange (ETDEWEB)

This report discusses the following topics: Fusion-fission in light nuclear systems; High-resolution Q-value measurement for the {sup 24}Mg+{sup 24}Mg reaction; Heavy-ion reactions and limits to fusion; and Hybrid MWPC-Bragg curve detector development.

1992-01-01

340

Radon concentration measurement in dwellings in Belgrade  

International Nuclear Information System (INIS)

The results of the radon concentration measurements in dwellings in Belgrade were shown in this paper. The measurements were done using long term method with diffusion cups equipped with solid state nuclear track detector LR-115-II or CR-39. (author).

341

Post-column reaction detector for platinum(II) antieoplastic agents  

Energy Technology Data Exchange (ETDEWEB)

The development and evaluation of a post-column reaction detector sensitive to platinum(II) complexes is presented in which sodium bisulfite is used as the derivatizing agent with potassium dichromate as an activating agent. The influences of mobile phase changes (i.e., pH, organic modifiers, electrolytes), oxygen, metal ions, and order of reagent addition on reaction kinetics and product yield are defined and used in optimization of detector response. Detection at lambda/sub max/ 290 nm results in an on-line post-column sensitivity of 40-60 ng/mL for selected cis-dichloroplatinum complexes and a sensitivity of 300-1200 ng/mL for four (substituted)-malonato-platinum complexes. The reaction detector is used to monitor the kinetics of aquation of cisplatin (CDDP) and to quantitate CDDP degradation in plasma. As the sensitivity for CDDP in plasma is comparable to that achieved from high pressure liquid chromatography (HPLC) ...

1984-03-01

342

Position sensitive and Bragg curve spectroscopy detector system for heavy ion reaction studies  

International Nuclear Information System (INIS)

A complete heavy ion identification system in heavy ion reaction studies consists, in general, of: 1) a position sensitive avalanche counter, and 2) ionization chamber to obtain total energy as well as a heavy ion identifier signal (such as the E#DELTA#E signal from a E-#DELTA#E type detector or the height of the Bragg peak that scales as Z of the heavy ion in a Bragg curve ionization chamber). In addition, a time-of-flight information may be needed to resolve the masses of the ions. With this motivation in mind, a composite detector system consisting of a Bragg curve spectroscopy ionization chamber (BCS-IC) and a one dimensional position sensitive parallel grid avalanche counter (XPS-PGAC) has been developed and used successfully at the BARC-TIFR pelletron accelerator facility. The design and performance of this gas detector system are reported. (author). 4 refs., 2 figs.

343

Photoconductive ultraviolet detectors based on ZnO films  

Energy Technology Data Exchange (ETDEWEB)

Properties of photoconductive ultraviolet detectors fabricated on ZnO films were presented. Highly c-axis oriented ZnO films were grown on glass substrates by pulsed laser deposition. Ultraviolet photodetectors were fabricated based on metal-semiconductor-metal planar structures. The photoresponsivity and the quantum efficiency are much higher in the ultraviolet range than in the visible range, and the peak values are around 360 nm. Photocurrent transients show that the detector has a large photocurrent with the peak value of 2.8 mA, and a slow photoresponse with a rise time of 5 min and a decay time of 7 min. The response curve of the detector is fitted well with exponential curve. The large photocurrent should result from the both effects of the accumulation of conduction electrons and the decrease of the barrier height between crystallites. The relaxation time constant {tau} obtained from the curve fitting represents the ...

2006-12-15

344

Photoconductive ultraviolet detectors based on ZnO films  

International Nuclear Information System (INIS)

Properties of photoconductive ultraviolet detectors fabricated on ZnO films were presented. Highly c-axis oriented ZnO films were grown on glass substrates by pulsed laser deposition. Ultraviolet photodetectors were fabricated based on metal-semiconductor-metal planar structures. The photoresponsivity and the quantum efficiency are much higher in the ultraviolet range than in the visible range, and the peak values are around 360 nm. Photocurrent transients show that the detector has a large photocurrent with the peak value of 2.8 mA, and a slow photoresponse with a rise time of 5 min and a decay time of 7 min. The response curve of the detector is fitted well with exponential curve. The large photocurrent should result from the both effects of the accumulation of conduction electrons and the decrease of the barrier height between crystallites. The relaxation time constant #tau# obtained from the curve fitting represents the ...

2006-12-15

345

Photoconducting properties of ultraviolet detectors based on GaN and Al{sub 1{minus}x}Ga{sub x}N films grown by ECR-MBE  

Energy Technology Data Exchange (ETDEWEB)

GaN and Al{sub 1{minus}x}Ga{sub x}N films were grown by the method of ECR-MBE. Absorption constants as a function of wavelength were determined from transmission measurements. Photoconducting detectors were fabricated from these films and characterized in terms of their spectral response and photoconductive gain. Mobility-lifetime products were determined from the measurement of photoconductive gain. The resistivity and mobility-lifetime products of the films were varied from 10--10{sup 9} ohm-cm and 10{sup {minus}3}--10{sup {minus}8} cm{sup 2}/V respectively by changing the microwave power in the ECR discharge from 20--60 watts. The change in the mobility-lifetime product is attributed to change in the lifetimes of the photogenerated carriers. This assumption is supported by direct measurement of detector response times. Finally, the authors report for the first time, the detection of alpha particles using GaN detectors.

1997-12-31

346

Photoconducting properties of ultraviolet detectors based on GaN and Al_1_-_xGa_xN films grown by ECR-MBE  

International Nuclear Information System (INIS)

GaN and Al_1_-_xGa_xN films were grown by the method of ECR-MBE. Absorption constants as a function of wavelength were determined from transmission measurements. Photoconducting detectors were fabricated from these films and characterized in terms of their spectral response and photoconductive gain. Mobility-lifetime products were determined from the measurement of photoconductive gain. The resistivity and mobility-lifetime products of the films were varied from 10--10"9 ohm-cm and 10"-"3--10"-"8 cm"2/V respectively by changing the microwave power in the ECR discharge from 20--60 watts. The change in the mobility-lifetime product is attributed to change in the lifetimes of the photogenerated carriers. This assumption is supported by direct measurement of detector response times. Finally, the authors report for the first time, the detection of alpha particles using GaN detectors.

1996-12-02

347

Performance assessment for EEG-based neonatal seizure detectors  

UK PubMed Central (United Kingdom)

ObjectiveThis study discusses an appropriate framework to measure system performance for the task of neonatal seizure detection using EEG. The framework is used to present an extended...Full Text Available

2011-03-01

348

Optical Modelling of the HFI Instrument on Board the Planck Surveyor  

Science.gov (United States)

The PLANCK SURVEYOR is a European Space Agency satellite mission to image the very faint anisotropies in the temperature of the Cosmic Microwave Background (CMB) radiation. Maynooth is actively participating in an international collaboration of scientists involved with the optical design of the High Frequency Instrument (HFI). This paper outlines research which has been undertaken in Maynooth concerned with numerical modelling of the optical characteristics of the multi-frequency array of detectors making up the HFI instrument. In the study the commercial software package ZEMAX was used to model the coupling of the focal plane HFI detectors to the PLANCK telescope. This package is particularly useful in the optical design of PLANCK because of the powerful optimisation features of the software. It is thus possible to readily determine the optimum positioning of the detectors in the focal plane of the telescope. Although the ...

1999-07-01

349

Online processing in the ALICE DAQ The detector algorithms  

CERN Document Server

ALICE (A Large Ion Collider Experiment) is the heavy-ion detector designed to study the physics of strongly interacting matter and the quark-gluon plasma at the CERN Large Hadron Collider (LHC). Some specific calibration tasks are performed regularly for each of the 18 ALICE sub-detectors in order to achieve most accurate physics measurements. These procedures involve events analysis in a wide range of experimental conditions, implicating various trigger types, data throughputs, electronics settings, and algorithms, both during short sub-detector standalone runs and long global physics runs. A framework was designed to collect statistics and compute some of the calibration parameters directly online, using resources of the Data Acquisition System (DAQ), and benefiting from its inherent parallel architecture to process events. This system has been used at the experimental area for one year, and includes more than 30 ...

2010-01-01

350

On-line real-time measurements of decontamination factor for a low-level waste incinerator  

Energy Technology Data Exchange (ETDEWEB)

The experiments at the incinerator for low-level wastes processing, (containing transuranium radionuclides) are described. Air decontamination factors and detector readings correction factors for efficiency and absorption are indicated.

1983-01-01

351

On-line real-time measurements of decontamination factor for a low-level waste incinerator  

International Nuclear Information System (INIS)

The experiments at the incinerator for low-level wastes processing, (containing transuranium radionuclides) are described. Air decontamination factors and detector readings correction factors for efficiency and absorption are indicated.

352

Novel remote sensing gas outburst detector  

Energy Technology Data Exchange (ETDEWEB)

The possibility has been explored of using a laser scattering technique to detect the imminent onset of rock activity associated with gas outbursts. The instrument described in this paper provides a sensitive, remote and rapid means of passively monitoring micro-seismic activity at the exposed face.

1984-08-01

353

Monte Carlo modeling of 60Co HDR brachytherapy source in water and in different solid water phantom materials  

UK PubMed Central (United Kingdom)

The reference medium for brachytherapy dose measurements is water. Accuracy of dose measurements of brachytherapy sources is critically dependent on precise measurement of the source–detector...Full Text Available

2010-01-01

354

Midwave infrared type-II InAs/GaSb superlattice detectors with mixed interfaces  

Science.gov (United States)

We report the growth and fabrication of midwave infrared InAs/GaSb strain layer superlattice (SLS) detectors. Growth of alternate interfaces leads to a reduced strain between the GaSb buffer and SLS ({delta}a{sub parallel}/a=-5x10{sup -4}), enabling the growth of active regions up to 3 {mu}m (625 periods). The structural, optical, and electrical properties of the active region were characterized using x-ray crystallography and photoluminescence, respectively. p-i-n detectors were grown using 625 periods of 8 ML (monolayer) InAs/8 ML GaSb as the active region. The {lambda}{sub cutoff} for the detectors was 4.6 {mu}m with a conversion efficiency of 32% at V{sub b}=-0.2 V. Detectivity was obtained using noise power spectral density measurements under 300 K 2{pi} field of view illumination and was equal to 5.2x10{sup 10} and 3x10{sup 10} cm Hz{sup 1/2}/W (V{sub b}=-0.02 V, T=80 K) in the white noise and 1/f noise limit (at 50 ...

2006-07-01

355

Measurement of gamma-ray detection efficiency in irradiated materials examination facility  

Energy Technology Data Exchange (ETDEWEB)

The detection efficiency of gamma scanning system in irradiated materials examination facility has been measured. Gamma-ray sources used in this experiment are Cs-Co standard sources a PWR spent fuel rod in which {sup 134}Cs and {sup 154}Eu peaks are clearly identified in the energy region of 500 to 1,600 keV. The distance between source and detector is about 1.6 m. A slit type collimator with 3 mm-width window and 30 mm-thick lead block are installed between source and detector. The detector is a HPGe detector. This equipment is mainly used in gamma scanning of irradiated nuclear fuel. The measured detection efficiency seems to be 1.89 x 10{sup -6} % for 1 MeV gamma-ray. With these results the activities of unknown sources could be measured. This results are expected to be used in the measurement of the absolute distribution of gamma emitting nuclides in nuclear fuel.

2001-05-01

356

MAGIC - Multi Anode Gas Ionization Chamber  

Energy Technology Data Exchange (ETDEWEB)

A novel approach to the Bragg curve spectroscopy is utilized to construct a charged particle detector which makes fragment elemental identification and energy measurement possible. The advantage of the construction includes good timing and spectroscopic properties with a very low energy threshold. ((orig.))

1994-12-01

357

Investigation of the decay scheme of $sup 177$W by means of $gamma$-- $gamma$ coincidences  

Science.gov (United States)

The gamma spectrum and gamma - gamma coincidences of /sup 177/W were measured with a Ge(Li) detector. A level scheme was proposed for /sup 177/Ta. (tr-auth)

1973-08-01

358

Instrumentation and Controls Division progress report, September 1, 1980-July 1, 1982  

Energy Technology Data Exchange (ETDEWEB)

Activities are reported by the Reactor Systems Section, Research Instrument Section, and the Measurement and Controls Engineering Section. Reactor system activities include dynamic analysis, survillanc and diagnostic methods, design and evaluation, detectors, facilities support, process instrumentation development, and special assignments. Activities in the Research Instrument Section include the Navy-ORNL RADIAC development program, advanced ..gamma.. and x ray detector systems, neutron detection and subcriticality measurements, circuit development, position-sensitive detectors, stand-alone computers, environmental monitoring-detectors and systems, plant security, engineering support for fusion energy division, engineering support for accelerator physics, and communications: radio, closed-circuit tv, and computer. Activities in the Measurement and Controls Engineering Section include the AVLIS program; ...

1982-12-01

359

Indoor radon concentration measurements by using SSNTD  

International Nuclear Information System (INIS)

In this paper, some results of the indoor radon concentration measurements are presented. Kodac track detectors LR 115, bare and in a cup were used for these measurements. Average winter/summer ratio was determined for the town of interest. (author). 5 refs, 1 fig., 1 tab.

360

Indoor radon concentration measurements  

International Nuclear Information System (INIS)

Some results of the indoor radon measurements are presented in this paper. Kodac track detectors LR-115 were used for these measurements. Average winter/spring ratio for indoor radon concentration was determined from the results obtained and is presented in this paper. (author).

361

Front-End-Electronics Communication software for multiple detectors in the ALICE experiment  

Energy Technology Data Exchange (ETDEWEB)

In the ALICE experiment at CERN, the Detector Control System (DCS) employs several interacting software components to accomplish its task of ensuring the correct operation and monitoring of the experiment. This paper describes the Front-End-Electronics Communication (FeeCommunication) software and its role within the DCS. The FeeCommunication software's central task is passing configuration and monitoring data between the top level DCS process control and the field devices of several detectors within ALICE. The lowest level of the FeeCommunication software runs on the DCS boards, specialized embedded systems which are in direct contact with the field devices and are physically located within the detector. The middle and upper layers run on standard PC hardware located in the counting room or other external locations. This paper focuses on the design and implementation of the FeeCommunication software and the steps ...

2006-02-15

362

Forschungszentrum Juelich, Institut fuer Kernphysik/COSY. Annual report 2004  

Energy Technology Data Exchange (ETDEWEB)

The following topics are dealt with: Detectors at COSY, major physics results at COSY, physics at external facilities, theoretical investigations, COSY operation and developments, preparations for FAIR, technical developments. (HSI)

2005-03-01

363

Feynmann variance-to-mean method  

Energy Technology Data Exchange (ETDEWEB)

The Feynmann and other fluctuation techniques have been shown to be useful for determining the multiplication of subcritical systems. The moments of the counting distribution from neutron detectors is analyzed to yield the multiplication value. We present the methodology and some selected applications and results and comparisons with Monte Carlo calculations.

1985-01-01

364

Explosives detection The problem and prospects  

Energy Technology Data Exchange (ETDEWEB)

Explosives molecules have a number of unique properties. These properties are discussed. They include low vapor pressures, electronegativity, ''stickiness,'' frangibility, and thermal instability. The program for developing an advanced explosives detector is described.

1984-07-01

365

Effect of Edge-Preserving Adaptive Image Filter on Low-Contrast Detectability in CT Systems: Application of ROC Analysis  

UK PubMed Central (United Kingdom)

Objective. For the multislice CT (MSCT) systems with a larger number of detector rows, it is essential to employ dose-reduction techniques. As...Full Text Available

2008-01-01

366

Does DaYa-Bay Reactor Play an Important Role in Theta_{13} of Lepton Mixing (PMNS) Matrix ?  

CERN Document Server

Reactor neutrinos play an important role in determining parameter theta_{13} in the lepton mixing (PMNS) matrix. Next important step on measuring PMNS matrix could be to build another reactor neutrino experiment in DaYa bay, China, to search the possible oscillations via sin^2 (2theta_{13}) and Delta m^2_{13}. We consider 4 different schemes for positions of three 8-ton detectors of this experiment, and simulate the results with respect to an array of assumed ''true'' values of physics parameters. Using three kinds of analysis method, we suggest a best scheme for DaYa-Bay which is to place a detector 2200m ~ 2500m symmetrically away from two reactors, and to put the other two detectors closer to their corresponding reactors respectively, almost at a 100m \\~ 200m distance. Moreover, with conservative assumption on the experimental technique, we construct series of allowed regions from our simulation results, and give ...

2004-01-01

367

Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures  

Energy Technology Data Exchange (ETDEWEB)

AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the ...

2002-04-01

368

Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures  

International Nuclear Information System (INIS)

AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the ...

2002-04-01

369

Daya Bay Neutrino Experiment  

CERN Document Server

The Daya Bay Neutrino Experiment is proposed to measure sin^2(2\\theta_{13}) to better than 0.01 at 90% C.L. in a three-year run. The experimental site, detector design, and background estimation are presented.

2006-01-01

370

Characterization system for Germanium detectors dedicated to gamma spectroscopy applied to nuclear waste  

International Nuclear Information System (INIS)

CEA-Valduc produces some radioactive waste (mainly alpha emitters). Legislation requires producers to sort their waste by activity and type of isotopes, and to package them in order to forward them to the appropriate reprocessing or storage facility. Our lab LMDE (laboratory for measurements on nuclear wastes and valuation) is in charge of the characterization of the majority of waste produced by CEA-Valduc. Among non-destructive methods to characterize a radioactive object, gamma-spectroscopy is one of the most efficient. We present to this conference the method we use to characterize nuclear waste and the system we developed to characterize our germanium detectors. The goal of this system is to obtain reliable numerical models of our detectors and calculate their efficiency curves. Measurements are necessary to checks models and improve them. These measurements are made on a bench using pinpoint sources ("1"3"3Ba, "1"5"2Eu) from 60 keV to ...

2009-06-07

371

Boron-Lined Neutron Detector Measurements  

Energy Technology Data Exchange (ETDEWEB)

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. Reported here are the results of tests of a newly designed boron-lined ...

2009-11-02

372

Black holes as detectors of tachyons  

International Nuclear Information System (INIS)

Tachyons fired into and absorbed by rotating black holes can violate the second and third laws of black hole physics. It is suggested that apparent break-downs of these laws in astrophysical black holes can indicate the existence of cosmic tachyons. (author).

373

Angular sensitivity distribution of detectors for BNCT  

Energy Technology Data Exchange (ETDEWEB)

The research on the therapy of brain tumors and others by the thermal neutron irradiation using research reactors is to kill tumor cells by accumulating boron at a tumor part, and using {alpha} particles and {sup 7}Li generated by {sup 10}B(n, {alpha}){sup 7}Li reaction of thermal neutrons, which is known as boron neutron capture therapy (BNCT). In Japan Atomic Energy Research Institute, the medical irradiation facility was installed in the thermal neutron column of the JRR-2, and as of March, 1994, 22 cases of irradiation have been carried out. In order to monitor the variation of thermal neutron flux during irradiation, the real time measurement using a simultaneous monitor is carried out, but there is the variation of measured values in the Si semiconductor, p-n junction detector possibly due to its direction dependence. The experiment was carried out to quantity the direction dependence of the detector by using the neutron radiography ...

1995-03-01

374

Symbol Error Rates of Maximum-Likelihood Detector: Convex/Concave Behavior and Applications  

CERN Document Server

Convexity/concavity properties of symbol error rates (SER) of the maximum likelihood detector operating in the AWGN channel (non-fading and fading) are studied. Generic conditions are identified under which the SER is a convex/concave function of the SNR. Universal bounds for the SER 1st and 2nd derivatives are obtained, which hold for arbitrary constellations and are tight for some of them. Applications of the results are discussed, which include optimum power allocation in spatial multiplexing systems, optimum power/time sharing to decrease or increase (jamming problem) error rate, and implication for fading channels.

2007-01-01

375

Response of track-etch dosemeters to environmental radon  

Energy Technology Data Exchange (ETDEWEB)

The reliability of outdoor radon concentration measurements using the track-etch technique is affected by the environmental conditions. Studies have been made to improve stability of nuclear tracks in detector material and to achieve a stable dosemeter response. A dosemeter was developed utilizing chemically etched MA-ND/alpha (CR-39) detector which is thermally insulated and protected against solar irradiation. The calibration showed that its response amounts to 0.21 {plus minus} 0.03 tracks m{sup -2}/Bqm{sup -3} day and was found to be in good agreement with theoretical prediction. (author).

1988-01-01

376

Real time neutron dosemeter response calculations  

International Nuclear Information System (INIS)

The response of a real time neutron dosemeter using a thin LiF target sandwiched between tow parallel surface barrier semiconductor detectors is studied for different neutron distributions and different angles of incidence. Calculations of the response function defined for a simultaneous detection by the two detectors of the particles emitted when the reaction "6Li(n,t)#alpha# occurs in the target are fulfilled by geometrical considerations of the reaction kinematics and the differential cross section variations. Finally, the efficiency of the studied detection systems is analyzed for dosimetric uses. (author).

1996-04-01

377

Radon gas monitoring survey for the determination of Radon Prone Areas in Lombardia  

Energy Technology Data Exchange (ETDEWEB)

Region Lombardia has carried out a radon gas monitoring survey on its territory to localize radon prone areas as by law 241/00 enacted. To plan the survey, the Lombardia territory has been divided into two different types according to the morphology as well as the presence of a substratum of rock. The area with hills and mountains has been investigated with more attention compared to the plain because we can assume higher variability in radon concentration distribution due to the geological and morphological characteristics. The territory subdivision was based on the standard grid.. of the techniregional cartography (8 x 5 km). To perform radon indoor concentration measurements about 3600 measuring points were selected. They are located at the ground floor of buildings with the characteristics to ensure the tests are representative and comparable. It has also been taken into account evaluations done with previous surveys in accordance with the defined specification of the sites. The ...

2006-07-01

378

Proceedings of the technical exchange meeting on passive radon monnitoring  

International Nuclear Information System (INIS)

The purpose of the meeting was to bring together a number of scientists active in the development and use of passive radon monitoring instrumentation, primarily activated charcoal detectors and alpha track detectors. Many of those present expressed a desire to receive copies of the viewgraphs and other materials presented. Most have supplied extended abstracts or complete reports. These materials are reproduced here as a Technical Measurements Center Report for the benefit of those attending the meeting and for others interested in passive radon monitoring. Individual papers were processed separately for the data base.

1987-09-21

379

Positron-Electron Pair Creation Near Threshold  

Science.gov (United States)

Positron-electron pair creation near the threshold energy is extremely difficult to investigate by both experiments and theory. First test experiments were performed at the ILL to determine the cross sections for positron-electron pair creation near threshold using prompt {gamma}-rays from different targets after neutron capture and conventional radioactive sources. Pair creation was studied in a Ge detector, which simultaneously acted as sample and detector. First results are presented which show a significant deviation from theoretical values near threshold.

2009-01-28

380

Performance of the transition radiation detector flown on the NMSU/WIZARD TS93 balloon-borne instrument  

Energy Technology Data Exchange (ETDEWEB)

It is built and tested a transition radiation detector (TRD) to discriminate positrons from protons in the balloon flight TS 93 experiment. It is presented the TRD performance using flight data obtaining a proton-positron rejection factor of the order of 10{sup -3}. During the 24 hour flight, the data in the momentum range 4-50 GeV/c are collected. Using the TRD together with the Silicon calorimeter, it is achieved an overall rejection factor of about 10{sup -5} of positron against the proton background over the entire momentum range.

1995-09-01

381

Passive dosimetry of radon and its daughters using solid state nuclear track detectors (SSNTDs)  

Energy Technology Data Exchange (ETDEWEB)

Indoor radon is a potential health hazard for the general public, especially in buildings with poor ventilation. A variety of dosemeters have been developed and used in surveys of radon concentration measurements. In this article the passive dosemeters which are based on solid state nuclear track detectors are reviewed. The principle of passive dosimetry and the factors affecting their performance are discussed. The characteristics of SSNTD materials in relation to their behaviour under different environmental conditions are tabulated and discussed. Results of radon surveys from selected studies are also presented. (Author).

1993-01-01

382

New focal plane detector system for the broad range spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A focal plane detector system consisting of a vertical drift chamber, parallel plate avalanche counters, and an ionization chamber with segmented anodes has been installed in the Broad Range Spectrometer at the Holifield Facility at Oak Ridge. The system, which has been designed for use with light-heavy ions with energies ranging from 10 to 25 MeV/amu, has a position resolution of approx. 0.1 mm, a scattering angle resolution of approx. 3 mrad, and a mass resolution of approx. 1/60.

1984-01-01

383

Measurement of the inclusive Z production cross section with the CMS detector  

CERN Document Server

First measurements of inclusive Z production cross sections in muon and electron decay channels at 7 TeV are presented for proton-proton collisions in the Compact Muon Solenoid (CMS) detector at the Large Hadron Collider (LHC). The comparison of the kinematic quantities as well as the studies of selection efficiencies demonstrate a good agreement between simulated events and current data. The measured inclusive cross section for Z($\\gamma^{*}$) production agrees with NNLO QCD cross section calculations and current parton distribution functions.

2010-01-01

384

Forward Physics with the CMS experiment at the Large Hadron Collider  

CERN Document Server

multi-parton interactions and underlying event structure, $\\gamma$-mediated processes and luminosity determination, Monte Carlo tuning and even MSSM Higgs discovery in central exclusive production. In this article, the forward detector instrumentation around the CMS interaction point is described and the prospects for diffractive and forward physics using the CMS forward detectors are summarized. In addition, first observation of forward jets as well as early measurements of the forward energy flow in the pseudorapidity range $3.15

2010-01-01

385

Daya Bay reactor anti-neutrino experiment  

International Nuclear Information System (INIS)

The Daya Bay Reactor Anti-Neutrino Experiment is a neutrino oscillation experiment designed to observe and measure the neutrino mixing angle ?13. The sensitivity goal is 0.01 in sin 22?13 at the 90% confidence level, a significant improvement over the current limit. This will be accomplished by measuring the relative rates and energy spectra of reactor electron antineutrinos with multiple detectors positioned at different baselines. Civil construction is currently under-way as detector designs and planning near completion. Commissioning activities should be completed by the end of 2010, followed by a three-year run.

2008-11-01

386

Daya Bay Neutrino Experiment: Goal, Progress and Schedule  

CERN Document Server

Daya Bay Neutrino Experiment is dedicated to measuring the last unobserved neutrino mixing angle theta_13. The predicted precision on sin^2(2theta_13) is 0.01 at 90% confidence level. This document briefly reviews the measurement method and detector construction status. The first two anti-neutrino detectors' dry run result is also discussed. The Daya Bay near hall data taking is expected to commence in the summer of 2011 and the data taking of all of the three halls in the summer of 2012.

2011-01-01

387

Conceptual design of the ATLAS EM muon chamber support structures  

CERN Document Server

The conceptual design of the support structures of the EM muon chambers is presented. On each side of the detector the EM chambers are arranged in four layers: one layer of MDTs and the three layers of TGCs. The chambers are mounted on four individual wheel structures per side. The four wheels are inclined by 1.23% and suspended from two longitudinal beams parallel to the beam axis. In order to allow for the opening of the ATLAS detector the wheels can be displaced longitudinally over a distance of 6 m. In addition individual wheels can be separated from each other by up to 1 m for maintenance purposes.

1998-01-01

388

Circuit design of PMT readout module for detector prototype of Daya Bay reactor neutrino experiment  

International Nuclear Information System (INIS)

This paper describes the design of PMT readout module for detector prototype of Daya Bay Reactor Neutrino Experiment. According to the design requirements of the readout module, the basic structure of the readout module is discussed. This paper also discusses how to realize the charge measurement and time measurement and data processing using a high performance FPGA. The DAQ system including three readout modules and one trigger module are well commissioned and doing data taking now. (authors)

2006-10-21

389

Application of proportional counters in Polish medicine and agriculture  

Energy Technology Data Exchange (ETDEWEB)

In the laboratory of Elementary Particle Physics and Detectors at the Faculty of Physics and Nuclear Techniques of the University of Mining and Metallurgy, research works on the development of proportional counters for the detection of X- and soft {gamma}-rays and {alpha}, {beta} particles have been carried out As a result of optimization of counters characteristic parameters such as: energy resolution, life time, count rate effect and temperature effect the operating stability has been reached and the elaborated detectors have been applied not only in research laboratories, but also in Polish industry, medicine and agriculture. Examples of above mentioned applications have been presented in the paper. (author). 7 refs, 7 figs, 1 tab.

1996-12-31

390

Acoustic response of piezoelectric lead-zirconate-titanate to a 400MeV/n xenon beam  

Energy Technology Data Exchange (ETDEWEB)

Characteristics of lead-zirconate-titanate (PZT) elements were studied by directly irradiating them with a 400 MeV/n Xe beam. The elements were sensitive to 10{sup 4} Xe ions and their output amplitudes were proportional to the beam intensity. An ensemble of those output amplitudes displayed a Bragg-curve-like response towards the range of 400 MeV/n Xe ion. We discuss the potential of PZT elements as a radiation detector and their application to high-intensity and high-energy detectors. (author)

2003-03-01

391

A study of aging effects in gas proportional detectors at the BAC calorimeter of the ZEUS experiment  

Energy Technology Data Exchange (ETDEWEB)

The multicell proportional chambers at the backing calorimeter of the ZEUS experiment at the storage ring HERA are supplied with a gas mixture of Ar/CO[sub 2] by an open gas system. Flow proportional counters with the build-up [sup 55]Fe sources are used as gas system monitoring detectors. The ZEUS experiment is planned to collect data for about 10 years. Therefore, the lifetime of the Ar/CO[sub 2] mixture should be known. In this paper, the results of laboratory tests and preliminary measurements of the aging effects for monitoring counters are presented. ((orig.))

1994-09-01

392

A new type active personal dosemeter with a solid state detector  

International Nuclear Information System (INIS)

We have developed a new type personal dosemeter by using a B-10 doped silicon p-n junction detector with a polyethylene radiator and a polyethylene moderator. The purpose of this study was to develop a real time neutron dosemeter with a nearly flat response in the energy range from thermal to 15 MeV and low angular dependence to the incident neutron direction. The neutron response of the dosemeter was obtained with the Monte Carlo calculation and the monoenergetic neutron experiment in a free air field and also under a condition attached on a phantom.

1988-04-01

393

A 40 GByte/s read-out system for GEM  

Energy Technology Data Exchange (ETDEWEB)

The preliminary design of the read-out system for the GEM (Gammas, Electrons, Muons) detector at the Superconducting Super Collider is presented. The system reads all digitized data from the detector data sources at a Level 1 trigger rate of up to 100 kHz. A total read-out bandwidth of 40 GBytes/s is available. Data are stored in buffers that are accessible for further event filtering by an on-line, processor farm. Data are transported to the farm only as they are needed by the higher-level trigger algorithms, leading to a reduced bandwidth requirement in the Data Acquisition System.

1994-04-01

394

''SEPIO NUANCE DT'' digital mammography system  

International Nuclear Information System (INIS)

In the past, the need for high quality images, i.e., very sharp and clear images, in mammography have prevented mammography equipment from being digitalized; however, recent advances in detection technology such as development of a high resolution digital X-ray detector have produced improvements in digital mammography. Digital mammography is expected to replace conventional film-screen mammography. We have developed a digital mammography system, named ''SEPIO NUANCE DT'', which is equipped with a direct conversion flat panel detector. The present paper describes the high basic performance and user-friendly functions of the system. (author)

2007-03-01

395

Photoresponsivity of ultraviolet detectors based on In{sub x}Al{sub y}Ga{sub 1-x-y}N quaternary alloys  

Energy Technology Data Exchange (ETDEWEB)

We describe the growth, fabrication, and characterization of an ultraviolet (UV) photoconductive detector based on In{sub x}Al{sub y}Ga{sub 1-x-y}N quaternary alloy that is lattice matched to GaN. The detector consisted of 0.1 {mu}m In{sub x}Al{sub y}Ga{sub 1-x-y}N alloy grown on 0.5-1.0 {mu}m GaN epilayer by metalorganic chemical vapor deposition. With varying indium concentration, the cut-off wavelength of the In{sub x}Al{sub y}Ga{sub 1-x-y}N detectors could be varied to the deep UV range. The most important and intriguing result is that the responsivity of the In{sub x}Al{sub y}Ga{sub 1-x-y}N quaternary alloy exceeded that of AlGaN alloy of a comparable cutoff wavelength by a factor of five. This makes the nitride quaternary alloy very important material for solar blind UV detectors applications particularly in the deep UV range where Al rich AlGaN alloys have problems with low quantum efficiency and ...

2000-08-07

396

Photoresponsivity of ultraviolet detectors based on In_xAl_yGa_1_-_x_-_yN quaternary alloys  

International Nuclear Information System (INIS)

We describe the growth, fabrication, and characterization of an ultraviolet (UV) photoconductive detector based on In_xAl_yGa_1_-_x_-_yN quaternary alloy that is lattice matched to GaN. The detector consisted of 0.1 #mu#m In_xAl_yGa_1_-_x_-_yN alloy grown on 0.5-1.0 #mu#m GaN epilayer by metalorganic chemical vapor deposition. With varying indium concentration, the cut-off wavelength of the In_xAl_yGa_1_-_x_-_yN detectors could be varied to the deep UV range. The most important and intriguing result is that the responsivity of the In_xAl_yGa_1_-_x_-_yN quaternary alloy exceeded that of AlGaN alloy of a comparable cutoff wavelength by a factor of five. This makes the nitride quaternary alloy very important material for solar blind UV detectors applications particularly in the deep UV range where Al rich AlGaN alloys have problems with low quantum efficiency and cracks due in part to lattice mismatch with ...

2000-08-07

397

Visualization and measurement of pressurized multiphase flow using neutron radiography of JRR-3M system  

Energy Technology Data Exchange (ETDEWEB)

Concerning the transient phenomenon of solid-gas two-phase flow, an attempt was made to visualize and measure a flow phenomenon in which three-dimensional bubbles occurred, grew and collapsed in the vicinity of a gas injection nozzle while solid particles were circulating. Such a phenomenon could not or hardly be visualized and measured by conventional methods. Such two-phase flow was visualized using neutron radiography, its characteristics measured and the usefulness of the visualization by neutron radiography confirmed. For this purpose, three-dimensional fluidized bed vessels, rectangular or cylindrical-shaped, made of steel or aluminum sheet, were prepared. Polyethylene or glass beads were used as solid particles and activated carbon particles as the tracer. In the experiment, nitrogen gas was blown into the vessel from one nozzle and distributors provided at the bottom of the vessel and exhausted from the top via the exhaust valve, by which the pressure in the vessel was ...

1998-01-01

398

Tritium in surface waters, tap water and in precipitation in Poland during the 1994-1999 period  

International Nuclear Information System (INIS)

Concentrations of tritium in environmental waters (precipitation, rivers, lakes, tap water) have been determined using electrolytic enrichment and liquid scintillation counting. In waters of big rivers (the Vistula and the Odra rivers), lakes and tap water the annual average concentrations were similar to each other being from 1.4 to 1.9 Bq x dm"-"3. These concentrations were similar to those in the precipitation in which they ranged from 1.7 to 2.2 Bq x dm"-"3. The lowest tritium concentrations were found in waters of the Seashore Region rivers (average for 1994-1999 was 1.1 Bq x dm"-"3). The tritium concentrations in surface waters and in precipitation are still higher than that of natural level. The data obtained show that tritium concentration in the water of rivers might depend on the size of drainage area. The observed seasonal variations of tritium concentration in the precipitation collected in Warsaw and at the Mount Sniezka indicate the stratospheric ...

2001-01-01

399

The Study of Phosphors Efficiency and Homogeneity using a Nuclear Microprobe  

Energy Technology Data Exchange (ETDEWEB)

Ion Beam Induced Luminescence (IBIL) and Ion Beam Induced Charge Collection (IBICC) have been applied in the study of the luminescence emission efficiency and investigation of the homogeneity of the luminescence emission in phosphors. The IBIL imaging was performed by using sharply focused ion beams or broad/partially-focused ion beams. The luminescence emission homogeneity in samples was examined to reveal possible distributed crystal-defects that may lead to the inhomogeneity of the luminescence emission in samples.The purpose of the study is to search for suitable luminescent thin films that have high homogeneity of luminescence emission, large IBIL efficiency under heavy ion excitation, and can be placed as a thin layer on the top of microelectronic devices to be analyzed with Ion Photon Emission Microscopy (IPEM). The emission yield was found to be low for organic materials, due to saturation of the light output dependence on the energy deposition of heavy ions. The emission yield ...

2000-12-08

400

Studies on the interaction of lidocaine with plasma proteins  

Energy Technology Data Exchange (ETDEWEB)

This study sought to quantitate lidocaine's interaction with alpha-1-acid glycoprotein (AAG), human serum albumin (HSA), and AAG in the presence of HSA, and to determine the extent of displacement of lidocaine from its binding site(s) by selected cardiovascular drugs (dipyridamole, disopyramide and quinidine). Since the limited experimental work reported in this area has involved the use of a single lidocaine concentration, this study involved the evaluation of a range of lidocaine concentrations. Lidocaine interaction with plasma proteins (AAG and HSA) was studied at 37/sup 0/C using an isothermal equilibrium dialysis system and /sup 14/C-lidocaine HCl. A dialysis membrane (M.W. cutoff 12,000 to 14,000) separated the two chambers of each dialysis cell. The extent of /sup 14/C-lidocaine dialysis was studied with respect to both drug and protein concentrations. Aliquots of each chamber of each of the cells were subjected to liquid scintillation counting ...

1985-01-01

401

Quantification of "2"3"5U and "2"3"8U activity concentrations for undeclared nuclear materials by a digital gamma-gamma coincidence spectroscopy  

International Nuclear Information System (INIS)

The purpose of this study is to investigate the possibility of verifying depleted uranium (DU), natural uranium (NU), low enriched uranium (LEU) and high enriched uranium (HEU) by a developed digital gamma-gamma coincidence spectroscopy. The spectroscopy consists of two NaI(Tl) scintillators and XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The results demonstrate that the spectroscopy provides an effective method of "2"3"5U and "2"3"8U quantification based on the count rate of their gamma-gamma coincidence counting signatures. The main advantages of this approach over the conventional gamma spectrometry include the facts of low background continuum near coincident signatures of "2"3"5U and "2"3"8U, less interference from other radionuclides by the gamma-gamma coincidence counting, and region-of-interest (ROI) imagine analysis for uranium enrichment determination. Compared to conventional gamma spectrometry, the method offers additional ...

2011-06-01

402

Photoluminescence of europium doped LiInO2 powder  

British Library Electronic Table of Contents (United Kingdom)

Abstract Lithium-indium oxide is one of the candidate materials as solid-state scintillators for solar neutrinos due to an inverse --decay of 115In to 115Sn. On the other hand, when doped with rare-earth ions such as Eu3+ or Sm3+, it becomes a promising phosphor material. In this report we present a simple solid-state procedure for preparation of LiInO2:Eu3+ powders. X-ray diffraction confirmed prod-uct in tetragonal structural form (space group: I41/amd) and no impurity phases were detected. Then, high resolution photoluminescence emission measurements were performed at room and low temperatures to find 5D0 - 7FJ. Emission kinetics from 5D0 level exhibited pure single exponential behavior with lifetime of about 1.5 ms. Maximum energy splitting of 7F1 manifold is recorded as a function of ...

2011-01-01

403

Optical modules for the neutrino telescope KM3NeT  

Energy Technology Data Exchange (ETDEWEB)

KM3NeT is a future deep-sea research infrastructure hosting a neutrino telescope with a volume of at least one cubic kilometer to be constructed in the Mediterranean Sea. The experiment aims to detect high-energy cosmic neutrinos using a 3D array of optical modules to collect the Cherenkov light induced by charged particles in the water. Upward going muons and showers produced in neutrino interactions with the surrounding matter will allow the search and study of possible sources of extra-terrestrial neutrinos. The design of optical modules makes an important impact on the performance and cost of the KM3NeT project. Several different optical module configurations are under consideration; based on glass pressure spheres containing: a large (10 in.) hemispherical photomultiplier tube (with a multi-anode version as an option); 25-31 3 in. photomultiplier tubes, or a crystal scintillator-based hybrid device (X-HPD). The features and advantages of each optical module ...

2010-11-01

404

Optical Turbulence Measurements and Models for Mount John University Observatory  

CERN Document Server

Site measurements were collected at Mount John University Observatory in 2005 and 2007 using a purpose-built scintillation detection and ranging system. $C_n^2(h)$ profiling indicates a weak layer located at 12 - 14 km above sea level and strong low altitude turbulence extending up to 5 km. During calm weather conditions, an additional layer was detected at 6 - 8 km above sea level. $V(h)$ profiling suggests that tropopause layer velocities are nominally 12 - 30 m/s, and near-ground velocities range between 2 -- 20 m/s, dependent on weather. Little seasonal variation was detected in either $C_n^2(h)$ and $V(h)$ profiles. The average coherence length, $r_0$, was found to be $7 \\pm 1$ cm for the full profile at a wavelength of 589 nm. The average isoplanatic angle, $\\theta_0$, was $1.0 \\pm 0.1$ arcsec. The mean turbulence altitude, $\\bar{h_0}$, was found to be $2.0\\pm0.7$ km above sea level. No average in the Greenwood frequency, $f_G$, could be established due ...

2010-01-01

405

On-line video image processing system for real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of gray scale and resolved to 240 x 256 picture elements (pixels) on a monochrome CRT, with the capability also to display 16 distinct colors on a RGB ...

1983-09-15

406

Natural radionuclides in drinking water in Argentina  

International Nuclear Information System (INIS)

As part of the national survey to evaluate natural radioactivity in the environment, concentration levels of natural uranium and "2"2"6Ra have been analyzed in over 300 drinking water samples taken from different locations in Argentina. "2"2"6Ra was determined by "2"2"2Rn emanation and liquid scintillation counting, and natural uranium by a fluorimetric procedure. Values ranging from 0.03 to 24 #mu#g.l"-"1 of natural uranium and from 0.06 to 50 #mu#g.l"-"1, were measured on drinking water samples taken from tap water systems and private wells, respectively. Concentrations up to 15 mBq.l"-"1 and to 22 mBq.l"-"1 of "2"2"6Ra were found in drinking water samples taken from tap water systems and private wells, respectively. These values are compared with the reference values accepted for drinking water. Based on the water intake rate, the age distribution and the measured concentrations, an annual collective effective dose of 1.9 man Sv and an individual committed ...

2000-05-01

407

Inventory of tritium concentration of waters in the Manche department; Inventaire des concentrations en tritium des eaux du Departement de La Manche  

Energy Technology Data Exchange (ETDEWEB)

For the inventory of water tritium concentration in the Manche department, it is the complementarity that animated the work opened during year 2001. To answer to a commune sensitivity such water quality, particularly drinking water at tap, the A.C.R.O. laboratory brought its know how to make and its technical means in the area of tritium analysis and the general council brought its know how to make and its logistics means in matter of sanitary control. This collaboration has allowed to supply an indication on the tritium content of the distribution waters of thirty of the most important cities of the department. Then, it allowed to inform on the radiological situation (in relation with the tritium presence) of coast waters and principal rivers waters. More than 160 controls have been realised between the months of march 2001 and february 2002. Only the tritium under the shape of tritiated water has been measured. The measures have been made by liquid scintillation ...

2007-07-01

408

Effects of atmospheric pressure on tracking failure of organic insulating materials; Yuki zetsuen zairyo no tai tracking sei ni oyobosu kiatsu no eikyo  

Energy Technology Data Exchange (ETDEWEB)

The effect of atmospheric pressure on tracking resistance of organic insulating materials were investigated in the range of 500 to 1007 hPa. The tracking resistance for Polycarbonate (PC), Modified Polyphenylene Oxide (M-PPO) and Paper Base Phenolic Resin Laminate (PL) increase with the decrease in atmospheric pressure. The scintillating discharges on these samples surface lead to the ignition. The tracking failure on these results from the ignition on the surface. For Polybutylene Terephthalate (PBT) and Polyethylene Terephthalate (PET), the tracking resistance decrease with the decrease in atmospheric pressure. The discharges observed on the these surface are the glow-like. The discharge area spreads on the surface between the electrodes at the lower pressure. The failure on this group results from the carbonization by the discharges on the surface. However, the tracking resistance for Unsaturated Polyester Resins (UP) has no significant dependence on lower ...

1995-11-20

409

Effect of water purification process in radioactive content: analysis on small scale purification plants; Efecto del proceso de purificacion de agua en el contenido radiactivo: analisis en plantas purificadoras a pequena escala  

Energy Technology Data Exchange (ETDEWEB)

Water from small scale purification plants is a low cost alternative for consumers in comparison to the bottled commercial presentations. Because of its low cost per liter, the consumption of this product has increased in recent years, stimulating in turn the installation of purification systems for these small businesses. The purpose of this study was to estimate the efficiency of small scale purification systems located in the cities of Zacatecas and Guadalupe, Zacatecas, to reduce the radioactive content of water. It was measured the total alpha and beta activity in water samples of entry and exit to process, through the liquid scintillation technique. In general it was observed that the process is more efficient in removing alpha that beta activity. The fraction of total alpha activity removed varied between 27 and 100%, while between 0 and 77% of the total beta activity was removed by the analyzed plants. In all cases, the total radioactivity level was lower ...

2009-10-15

410

Baccharis Salicifolia development in the presence of high concentrations of uranium in the arid environment of San Marcos, Chihuahua  

International Nuclear Information System (INIS)

In humid zones and marine environments the bio indicator contaminants by trace elements are well established. However, in arid zones it is more difficult to find these tools because there is less biodiversity. The objective of this paper was to analyze the behavior of the Baccharis salicifolia plant in areas with high uranium concentration in arid zones, to determine the characteristics of tolerance and possible use as a bio monitor for the presence of such contaminants. For this project a uraniferous zone was selected in San Marcos, located northwest of the City of Chihuahua. A total of 8 sampling points of the plant and soil were located here. Each sample was divided into the root and the stem and leaves to determine the specific activity of the uranium in both parts of the plant and its sediments. The determination of the specific activities of the total uranium in the samples was obtained by liquid scintillation with alpha-beta separation. The results indicate ...

2011-02-01

411

An on-line video image processing system for real-time neutron radiography  

International Nuclear Information System (INIS)

The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of gray scale and resolved to 240 x 256 picture elements (pixels) on a monochrome CRT, with the capability also to display 16 distinct colors on a RGB ...

1983-09-01

412

An Investigation of the Relationship Between Tritium in Groundwater and the Dendrochronology of Tritium in Trees at the Savannah River Site. Final report  

Energy Technology Data Exchange (ETDEWEB)

This project was supported through ERDA to demonstrate that the temporal distribution of tritium can be documented by the analysis of bound hydrogen in annual tree-ring samples. The project focuses on two sample locations at the Savannah River Site (SRS), a nuclear material production facility located in Aiken, SC. The SRS provided samples of cross-sections from a single tree that were to be pooled together for analysis. Annual tree-rings were identified in each cross-section sample and separated for the period 1954 to 1993. These annual samples were ground and chemically treated to separate the hollocellulose fraction of the wood, then subsequently combusted and the resulting water counting using low-level liquid scintillation counting equipment. Additionally, the ground annual tree-rings were gamma-counted to determine any temporal variation in radionuclide activity and analyzed with x-ray fluorescence to find any temporal variation in trace-element ...

1995-03-21

413

Delayed neutron energy spectra following fast fission of "2"3"8U  

International Nuclear Information System (INIS)

Delayed neutron energy spectra have been measured for six delay-time intervals following the fast fission of "2"3"8U nuclei. The delay-time intervals span the range 0.17 to 10.2 seconds following initial fission while the measured spectra span neutron energies from 10 keV to 4 MeV. The experiment was performed utilizing the UMass/Lowell 5.5 MV Van de Graff accelerator to produce fast neutrons for inducing fission in a "2"3"8U lined fission chamber. The fission fragments were flushed via a helium jet stream to a well-shielded counting room where they were deposited onto a moving tape (magnetic audio tape) and transferred to a beta-neutron time-of-flight spectrometer. By adjusting the tape speed, composite delayed neutron time-of-flight spectra were measured for several different delay-time intervals. These measurements involved beta-neutron coincidences with "6Li-loaded glass scintillators for neutron energies from 10 keV to 450 keV and Bicron BC 501 liquid ...

414

Year-long comparison of two techniques to monitor outdoor radon concentrations at Shiprock, New Mexico  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center (TMC) at the DOE Grand Junction Projects Office (GJPO) in Grand Junction, Colorado, to standardize, calibrate, and compare measurements made in support of DOE remedial action programs. Outdoor radon concentration measurements were made by the TMC in Shiprock, New Mexico, to compare two different methods of measuring radon in an attempt to determine the feasibility of using passive alpha-track detectors to assess the adequacy of remedial action undertaken at the Shiprock uranium mill tailings pile. The results of the first three quarters of monitoring have been detailed in previous reports. An analysis of the data from the fourth quarter of monitoring at Shiprock reveals a somewhat poorer correlation between the two sets of measurements than was seen in the third quarter of this study, but a better correlation than was found for the first ...

1988-08-01

415

Temperature dependence of the performance of ultraviolet detectors  

Energy Technology Data Exchange (ETDEWEB)

We present the results of a comprehensive study of the temperature dependences of the quantum efficiency for ultraviolet detectors based on GaAs, GaP and 4H--SiC Schottky structures, and on Si, GaAs p-n structures. For ultraviolet detectors based on Schottky structures, the quantum efficiency increases with increasing temperature for all photon energies, even including the semiconductor intrinsic absorption region. On the other hand, for ultraviolet detectors based on p-n structures, the quantum efficiency is practically temperature independent in the semiconductor intrinsic absorption region. The change in the quantum efficiency for the GaAs and Si detectors is less than 0.01% per degree. To explain the measurements, a variable trap occupancy model is presented. Subsurface imperfections of the semiconductor cause fluctuations in the profile of the conduction band and the valence band edges. In the ...

2003-08-21

416

Temperature dependence of the performance of ultraviolet detectors  

International Nuclear Information System (INIS)

We present the results of a comprehensive study of the temperature dependences of the quantum efficiency for ultraviolet detectors based on GaAs, GaP and 4H--SiC Schottky structures, and on Si, GaAs p-n structures. For ultraviolet detectors based on Schottky structures, the quantum efficiency increases with increasing temperature for all photon energies, even including the semiconductor intrinsic absorption region. On the other hand, for ultraviolet detectors based on p-n structures, the quantum efficiency is practically temperature independent in the semiconductor intrinsic absorption region. The change in the quantum efficiency for the GaAs and Si detectors is less than 0.01% per degree. To explain the measurements, a variable trap occupancy model is presented. Subsurface imperfections of the semiconductor cause fluctuations in the profile of the conduction band and the valence band edges. In the ...

2003-08-21

417

Subcriticality measurements for two coupled uranyl nitrate solution tanks using /sup 252/Cf-source-driven neutron noise analysis methods  

Energy Technology Data Exchange (ETDEWEB)

The subcriticality of two interacting solution tanks was determined using /sup 252/Cf-source-driven neutron noise analysis methods. These experiments were the first test of this method for an interacting system with materials (in this case, uranyl nitrate) typical of nuclear materials in processing plants. The experiments were performed to test the conclusions from previous interaction experiments with uranium metal discs for a fissile system with moderation, and to provide data to test theoretical models for coupled systems. The uranium metal experiments showed that the subcritical neutron multiplication factor, k/sub eff/, could be determined using point kinetics without any correction for spatial effects from measurements with the source and detectors located adjacent to the same cylinder, whereas for source-detector configurations with either the source and/or detectors adjacent to different cylinders, a model which ...

1986-01-01

418

Reactivity surveillance experiments with the engineering mock-up core of the fast flux test facility reactor  

International Nuclear Information System (INIS)

An experiment was performed with a mock-up of the core of the Fast Flux Test Facility (FFTF) reactor to evaluate three reactivity measurement methods for application to liquid-metal fast breeder reactors (LMFBR): modified source multiplication measurements with the low-level flux monitor for refueling (35 dollars subcritical) of FFTF, noise analysis to 35 dollars subcritical, and inverse kinetics rod drop to 12 dollars subcritical. To investigate the spatial dependence of these measurement methods and to resolve discrepancies previously reported, detectors were placed in the core, reflector, and radial shield, and experimental data were collected with the reactivity at near delayed criticality to 35 dollars subcritical. Conclusions from this experiment are the following. Low-level flux monitors in the shield of the FFTF will be adequate for reactivity surveillance during refueling, using the modified source multiplication method calibrated near critical by an ...

419

Considerations for the next Compton telescope mission  

International Nuclear Information System (INIS)

A high resolution Compton telescope has been identified by the Gamma Ray Astronomy Program Working Group (GRAPWG) as the highest priority major mission in gamma ray astrophysics following GLAST. This mission should provide 25-100 times improved sensitivity, relative to CGRO and INTEGRAL, for MeV gamma ray lines. It must have good performance for narrow and broad lines and for discrete and diffuse emissions. Several instrumental approaches are being pursued to achieve these goals. We discuss issues relating to this mission including alternative detector concepts, instrumental configurations, and background reduction techniques. We have pursued the development of position-sensitive solid-state detectors (Ge, Si) for a high spectral resolution Compton telescope mission. A #approx#1 m2 germanium Compton telescope of position-sensitive germanium detectors was the basis for one of the GRAPWG concepts. Preliminary Monte Carlo ...

2000-04-12

420

Basic study of entire whole-body PET scanners based on the OpenPET geometry  

International Nuclear Information System (INIS)

A conventional PET scanner has a 15-25 cm axial field-of-view (FOV) and images a whole body using about six bed positions. An OpenPET geometry can extend the axial FOV with a limited number of detectors. The entire whole-body PET scanner must be able to process a large amount of data effectively. In this work, we study feasibility of the fully 3D entire whole-body PET scanner using the GATE simulation. The OpenPET has 12 block detector rings with the ring diameter of 840 mm and each block detector ring consists of 48 depth-of-interaction (DOI) detectors. The OpenPET has the axial length of 895.95 mm with five parts of 58.95 mm open gaps. The OpenPET has higher single data loss than a conventional PET scanner at grouping circuits. NECR of the OpenPET decreases by single data loss. But single data loss is mitigated by separating the axially arranged detector into two parts. Also, ...

2010-09-01

421

Track Reconstruction and Performance of DRIFT Directional Dark Matter Detectors using Alpha Particles  

CERN Document Server

First results are presented from an analysis of data from the DRIFT-IIa and DRIFT-IIb directional dark matter detectors at Boulby Mine in which alpha particle tracks were reconstructed and used to characterise detector performance--an important step towards optimising directional technology. The drift velocity in DRIFT-IIa was [59.3 +/- 0.2 (stat) +/- 7.5 (sys)] m/s based on an analysis of naturally-occurring alpha-emitting background. The drift velocity in DRIFT-IIb was [57 +/- 1 (stat) +/- 3 (sys)] m/s determined by the analysis of alpha particle tracks from a Po-210 source. 3D range reconstruction and energy spectra were used to identify alpha particles from the decay of Rn-222, Po-218, Rn-220 and Po-216. This study found that (22 +/- 2)% of Po-218 progeny (from Rn-222 decay) are produced with no net charge in 40 Torr CS2. For Po-216 progeny (from Rn-220 decay) the uncharged fraction is (100 +0 -35)%.

2007-01-01

422

Thermal Design and Performance of the Gamma-Ray Spectrometer for the MESSENGER Spacecraft  

Energy Technology Data Exchange (ETDEWEB)

A gamma-ray spectrometer (GRS) has been built and delivered to the Mercury MESSENGER spacecraft which launched on August 3, 2004, from Cape Canaveral, Florida. The GRS, a part of seven scientific instruments on board MESSENGER, is based on a coaxial high-purity germanium detector. Gamma-ray detectors based on germanium have the advantage of providing excellent energy resolution, which is critical to achieving the science goals of the mission. However, germanium has the disadvantage that it must operate at cryogenic temperatures (typically {approx}80 K). This requirement is easy to satisfy in the laboratory but difficult near Mercury, which has an extremely hot thermal radiation environment. To cool the detector, a Stirling cycle mechanical cooler is employed. In addition, radiation and conduction techniques a are used to reduce the GRS heat load. Before delivering the flight sensor, a complete thermal prototype was built ...

2004-10-13

423

TIARA: A large solid angle silicon array for direct reaction studies with radioactive beams  

International Nuclear Information System (INIS)

A compact, quasi-4? position sensitive silicon array, TIARA, designed to study direct reactions induced by radioactive beams in inverse kinematics is described here. The Transfer and Inelastic All-angle Reaction Array (TIARA) consists of 8 resistive charge division detectors forming an octagonal barrel around the target and a set of double-sided silicon-strip annular detectors positioned at each end of the barrel. The detector was coupled to the ?-ray array EXOGAM and the spectrometer VAMOS at the GANIL Laboratory to demonstrate the potential of such an apparatus with radioactive beams. The 14N(d,p)15N reaction, well known in direct kinematics, has been carried out in inverse kinematics for that purpose. The observation of the 15N ground state and excited states at 7.16 and 7.86 MeV is presented here as well as the comparison of the measured proton angular distributions with DWBA calculations. Transferred l-values are in ...

2010-03-11

424

Research in heavy-ion nuclear physics. [Dept. of Physics and Astronomy, The Univ. of Kansas, Lawrence, Kansas  

Energy Technology Data Exchange (ETDEWEB)

Attention was focused on the fission process in light nuclear systems. A model calculation based on the transition-state model of nuclear fission was applied to [sup 47]V fission as populated through multiple entrance channels and to fusion-fission cross sections for production of [sup 28]Al through three different entrance channels. Angular distributions are shown for different mass channels of the [sup 29]Si+[sup 27]Al reaction at E[sub lab] = 125 MeV. Pronounced structure is seen in the symmetric and near-symmetric fission channels from the [sup 24]Mg+[sup 24]Mg reaction; cross sections for binary fragment emission are shown for E[sub lab] = 90 MeV. A large Bragg-curve detector was used in this experiment. Ways to optimize detector response were studied; in addition, the Bragg detector was instrumented with an internal position-sensitive multiwire proportional counter.

1992-01-01

425

Research in heavy-ion nuclear physics. Annual progress report, May 1, 1992--April 30, 1993  

Energy Technology Data Exchange (ETDEWEB)

Attention was focused on the fission process in light nuclear systems. A model calculation based on the transition-state model of nuclear fission was applied to {sup 47}V fission as populated through multiple entrance channels and to fusion-fission cross sections for production of {sup 28}Al through three different entrance channels. Angular distributions are shown for different mass channels of the {sup 29}Si+{sup 27}Al reaction at E{sub lab} = 125 MeV. Pronounced structure is seen in the symmetric and near-symmetric fission channels from the {sup 24}Mg+{sup 24}Mg reaction; cross sections for binary fragment emission are shown for E{sub lab} = 90 MeV. A large Bragg-curve detector was used in this experiment. Ways to optimize detector response were studied; in addition, the Bragg detector was instrumented with an internal position-sensitive multiwire proportional counter.

1992-01-01

426

Radioanalytical methods of rare earth element determination  

International Nuclear Information System (INIS)

Instrumental neutron activation analysis (INAA) and radionuclide X-ray fluorescence analysis (RXFA) were used for the determination of rare earth elements. For INAA, solution obtained by sample decomposition was dripped onto filter paper, enclosed and sealed into a polyethylene foil. The sample was activated in reactor WWR-S over a period of 4 to 6 hours with a neutron fluence of 10"1"3cm"-"2. Gamma radiation measurement was carried out with a planar and a coaxial HP-Ge detector in three decay periods. La, Ce, Nd, Sm, Eu, Gd, Tb, Ho, Tm, Yb and Lu were determined. The advantage of the method is its accuracy and high sensitivity, the disadvantage is the time-consuming analysis. The RXFA method was used as a rapid and operative method for the analysis of loose ore samples, aqueous and organic solutions of rare earth elements. For exciting X-ray radiation, "2"4"1Am was used and the radiation of K-lines was detected with a planar Si(Li) detector. ...

1989-06-01

427

National and International Security Applications of Cryogenic Detectors - Mostly Nuclear Safeguards  

International Nuclear Information System (INIS)

As with science, so with security--in both arenas, the extraordinary sensitivity of cryogenic sensors enables high-confidence detection and high-precision measurement even of the faintest signals. Science applications are more mature, but several national and international security applications have been identified where cryogenic detectors have high potential payoff. International safeguards and nuclear forensics are areas needing new technology and methods to boost speed, sensitivity, precision and accuracy. Successfully applied, improved nuclear materials analysis will help constrain nuclear materials diversion pathways and contribute to treaty verification. Cryogenic microcalorimeter detectors for X-ray, gamma-ray, neutron, and alpha-particle spectrometry are under development with these aims in mind. In each case the unsurpassed energy resolution of microcalorimeters reveals previously invisible spectral features of nuclear materials. ...

2009-12-16

428

MicroDiffraction in the Scanning Electron Microscope (SEM)  

Science.gov (United States)

The identification of crystallographic phases in the scanning electron microscope (SEM) has been limited by the lack of a simple way to obtain electron diffraction data of an unknown while observing the micro structure of the specimen. With the development of Charge Coupled Device (CCD) based detectors, backscattered electron Kikuchi patterns (BEKP), alternately referred to as electron backscattered diffraction patterns (EBSP), can be easily collected. Previously, BEKP has been limited to crystallographic orientation studies due to the poor pattern quality collected with video rate detector systems. With CCD detectors, a typical BEKP can now be acquired from a micron or sub-micron-sized crystal using an exposure time of 1-10 seconds with an accelerating voltage of 10-40 kV and a beam current as low as 0.1 nA. Crystallographic phase analysis using BEKP is unique in that the properly equipped SEM permits high magnification ...

1997-12-31

429

Micro-strip metal foil detectors for the beam profile monitoring  

Energy Technology Data Exchange (ETDEWEB)

The Micro-strip Metal Foil Detectors (MMFD) designed and used for the Beam Profile Monitoring (BPM) are discussed. The results obtained for the MMFDs produced by different technologies are presented. The MMFD deposited onto the 20 {mu}m thick Si-wafer has been used for the BPM of the 32 MeV alpha-particle beam at the MPIfK (Heidelberg) Tandem generator. Another MMFD with totally removed Si-wafer at the working area has been applied for the on-line X-ray BPM at the HASYLAB (DESY). One may conclude that the developed technology of the micro-strip metal detector manufacturing allows to provide non-destructive measurement of X-ray intensity distribution over area of up to 50 mm{sup 2} with an accuracy of 10-20 {mu}m with a possibility of its improvement by a factor 5. A sub-micron position resolution is expected by applying electron lithography for the strip pattern production.

2005-07-01

430

Methods of selection in heavy ion collisions at Fermi energies and de-excitation modes with the INDRA multi-detector; Methodes de tri dans les collisions d'ions lourds aux energies de Fermi et modes de desexcitation avec le multidetecteur INDRA  

Energy Technology Data Exchange (ETDEWEB)

The progress made in particle detection, particularly the design of multi-detectors, like INDRA, that cover a solid angle of almost 4{pi}, have given a new impetus to heavy ion collisions. These detectors are demanding for an efficient way of selecting events that have a common history or similar features, for instance the events representing the de-excitation of a unique emitter. The problem is to find the adequate variable on which the discrimination can be based. Different methods are proposed in this work, the common point is that they require efficient models to reproduce and analyse experimental data in order to apprehend the equation of state of nuclear matter. Most of these models are based on the numerically solving of the nuclear Boltzmann equation. The application to the Ni + Ni reaction with an energy ranging from a few A.MeV to more than 50 A.MeV illustrates this work. (A.C.)

2005-11-15

431

Investigation of the frequency-dependence of the MTC noise estimator  

International Nuclear Information System (INIS)

The Moderator Temperature Coefficient of reactivity (MTC) was earlier proven to be properly determined via noise analysis when the neutron noise is measured locally and when the radial average of the moderator temperature noise is used. Nevertheless, measurements revealed that the MTC was correctly estimated on a much narrower frequency band (0.6 - 0.7 Hz) than expected (0.1 - 1.0 Hz). The present paper investigates the effect of the feedback on the MTC determination using this new MTC noise estimator (which could explain the deviation at low frequencies, i.e. between 0.1 - 0.5 Hz) and the effect of the detector time constants (which could explain the deviation at high frequencies, i.e. between 0.7 - 1.0 Hz). For that purpose, a coupled neutronic/thermalhydraulic model of the Ringhals-3 PWR is developed in the frequency-domain, based on a radial 2-dimensional heterogeneous representation of the core. The transfer function of the detectors is ...

2005-09-12

432

Interim cryo-cooler/detector report  

Energy Technology Data Exchange (ETDEWEB)

This report describes development of an electronic system designed to reduce vibration generated by a cryocooler. The diminished vibration makes it practical to use the active cooler to extract heat from a portable gamma ray detector instrument. The system was developed for a Sunpower cryocooler with an integrated counterbalance mass. The overall momentum cancellation approach is also applicable to other similar cryocoolers. The cancellation system is an assembly of several components tailored to accomplish the required vibration reduction with minimum power consumption and volume. It is designed to be powered by a 18--32 Volt battery. Up to ten harmonics of the 58.65 Hz drive frequency are controlled. In addition to the vibration cancellation, the electronic system produces the drive signal for the cryocooler and regulates the cooler temperature. The system employs a sinusoidal drive to reduce the amount of higher harmonic vibration. A digital signal processor ...

1995-04-19

433

Indoor and outdoor Radon concentration measurements in Sivas, Turkey, in comparison with geological setting  

Energy Technology Data Exchange (ETDEWEB)

Indoor and soil gas Radon ({sup 222}Rn) concentration measurements were accomplished in two stages in Sivas, a central eastern city in Turkey. In the first stage, CR-39 passive nuclear track detectors supplied by the Turkish Atomic Energy Authority (TAEA) were placed in the selected houses throughout Sivas centrum in two seasons; summer and winter. Before the setup of detectors, a detailed questionnaire form was distributed to the inhabitants of selected houses to investigate construction parameters and properties of the houses, and living conditions of inhabitants. Detectors were collected back two months later and analysed at TAEA laboratories to obtain indoor {sup 222}Rn gas concentration values. In the second stage, soil gas {sup 222}Rn measurements were performed using an alphameter near the selected houses for the indoor measurements. Although {sup 222}Rn concentrations in Sivas were quite low in relation with the ...

2010-11-15

434

Emergency core cooling device  

International Nuclear Information System (INIS)

In an existent emergency reactor core cooling device, if a ruptures should occure in a pipeline of a gravitational dropping type reactor core cooling system pool (GDCS) due to some or other causes, a portion of GDCS pool water was flown out of the ruptured port and could not be used for reactor core cooling. Then, a difference pressure detector is disposed to a GDCS pipeline at the inlet of a reactor pressure vessel. When it is judged by the detector, that coolants flow to the outside of the injection pipeline, an injection value disposed to the GDCS pipeline is closed by the difference pressure signal. Even if a rupture should occur on the side of the pressure vessel at downstream to the check value of the GDCS pipeline, since backflow is caused at the pressure container inlet of the GDCS pipeline with the rupture port, the rupture is detected by the difference pressure detector to close the injection valve. Therefore, ...

1990-10-29

435

Edge filter and fringe imaging for laser Doppler wind speed measurement  

Science.gov (United States)

Optical measurement of the Doppler shift of laser backscatter, using a near-IR, visible, or ultraviolet laser, is potentially more robust and field reliable than coherent, heterodyne measurement with an IR laser. The direct measurement of the displacement of Fabry-Perot interference fringes is possible, but entails expensive, technically challenging, imaging detectors. The 'edge technique' permits Doppler shift measurements with relatively simple detectors and detector electronics, and has been implemented with Fabry-Perot etalons and with atomic line filters. Simple analytical models of the fringe imaging and edge detection techniques are presented, permitting ready calculation of the potential performance of either, for various atmospheric conditions and for various lidar hardware configurations. The predictions of the analytical models are confirmed by computer models, which in turn allow more detailed considerations of ...

1997-08-01

436

Development of a phoswich detector to detect neutrons in the charged-particle mixed field  

Energy Technology Data Exchange (ETDEWEB)

Manned-space missions bring an exposure due to corpuscular radiations of which nature is quite different from what we encounter in the ground environment. In the space environment, many secondaries are produced through interactions of cosmic ray primaries with the spacecraft wall and other surrounding materials. Among this large variety of radiation components in the space, the contribution of neutrons to the radiation exposure of astronauts has remained to be studied. Up to today, efforts to measure neutron dose equivalent have been made using passive detector systems. Considering uncertainties involved in current measurements and estimations of high energy neutrons, and their increasing importance for future manned missions, it is necessary to measure neutron spectrum in the spacecraft under realistic conditions. The neutron spectra have never been measured on board a spacecraft, because the neutron measurement requires to discriminate between the neutron events ...

1997-07-01

437

Construction and Calibration of the Laser Alignment System for the CMS Tracker  

CERN Document Server

The CMS detector (Compact Muon Solenoid) is under construction at one of the four proton-proton interaction points of the LHC (Large Hadron Collider) at CERN, the European Organization for Nuclear Research (Geneva, Switzerland). The inner tracking system of the CMS experiment consisting of silicon detectors will have a diameter of 2.4 m and a length of 5.4 m representing the largest silicon tracker ever. About 15000 silicon strip modules create an active silicon area of 200 m2 to detect charged particles from proton collisions. They are placed on a rigid carbon fibre structure, providing stability within the working conditions of a 4 T solenoid magnetic field at ?10oC. Knowledge of the position of the silicon detectors at the level of 100 ?m is needed for an efficient pattern recognition of charged particle tracks. Metrology methods are used to survey tracker subdetectors and the integrated Laser Alignment System (LAS) ...

2006-01-01

438

Body weight-tailored contrast material injection protocol for 64-detector row computed tomography coronary angiography  

International Nuclear Information System (INIS)

The aim of this study was to assess the body weight-tailored contrast material injection protocol for 64-detector computed tomography (CT) to maintain optimal coronary CT attenuation. A total of 60 patients who underwent CT coronary angiography were assigned to one of three groups: protocol A, total of 0.7 ml kg"-"1 with 300 mg I/ml iodine concentration; protocol B, total of 0.6 ml kg"-"1 with 350 mg I/ml; protocol C, total of 0.7 ml kg"-"1 with 350 mg I/ml. The injection duration was 10 s in all patients. The proportion of intracoronary attenuation values >325 Hounsfield unit (HU) was compared on a per-vessel and per-patient basis. The attenuation value was significantly more likely to exceed 325 HU with protocol C (95% for reader 1 and 90% for reader 2) than with protocol A or B on the per-vessel analysis (P325 HU) with 64-detector CT when using an injection duration of 10 s. (author)

2011-01-01

439

Application of a finite element method to leak before break (LBB) of a heat exchanger  

International Nuclear Information System (INIS)

The leak before break (LBB) concept is difficult to apply to a structure with a thin tube that is immersed in a water environment. A heat exchanger in a nuclear power plant is such a structure. The present paper addresses an application of the LBB concept to a heat exchanger in a nuclear power plant. The minimum leaked coolant amount containing the radioactive material which can activate the radiation detector device installed near the heat exchanger is assumed. The postulated initial flaw size that cannot grow to the critical flaw size within the time period to activate the radiation detector is justified. In this case, the radiation detector can activate the warning signal caused by coolant leakage from initially postulated flaws of the heat exchanger. The nuclear plant can safely shutdown when this occurs. Since the postulated initial flaw size can not grow to the critical flaw size, the structural integrity of the heat ...

2003-08-17

440

Accelerator related background in the CMS detector at LHC  

International Nuclear Information System (INIS)

Complete calculations of the accelerator related background in the muon spectrometer of the CMS detector at the Large Hadron Collider are presented. The simulations have been performed with the STRUCT multi-turn tracking code and the MARS and FLUKA cascade codes taking into account latest information of the LHC lattice, vacuum conditions, beam cleaning system and the shielding and layout of the CMS experiment. Beam loss distributions in the interaction regions and their vicinities and their contribution to the background levels in the muon spectrometer of CMS are analyzed. The studies show that hadronic and electromagnetic components of machine background are efficiently suppressed by the proposed CMS shielding. High energy muons penetrate through the shielding, but in positions of significance they do not contribute more than a few percent compared to the background generated by the pp-collisions. It is anticipated that the relative contribution of accelerator ...

441

A Risk-Based Sensor Placement Methodology  

Energy Technology Data Exchange (ETDEWEB)

A risk-based sensor placement methodology is proposed to solve the problem of optimal location of sensors or detectors to protect population against the exposure to and effects of known and/or postulated chemical, biological, and/or radiological threats. Risk is calculated as a quantitative value representing population at risk from exposure against standard exposure levels. Historical meteorological data are used to characterize weather conditions as the frequency of wind speed and direction pairs. The meteorological data drive atmospheric transport and dispersion modeling of the threats, the results of which are used to calculate risk values. Sensor locations are determined via an iterative dynamic programming algorithm whereby threats captured or detected by sensors placed in prior stages are removed from consideration in subsequent stages. In addition to the risk-based placement algorithm, the proposed methodology provides a quantification of the marginal ...

2008-10-01

442

Use of neural network techniques to identify cosmic ray electrons and positrons during the 1993 balloon flight of the NMSU/Wizard-TS93 instrument  

Energy Technology Data Exchange (ETDEWEB)

The detectors used in the TS93 balloon flight produced a large volume of information for each cosmic ray trigger. Some of the data was visual in nature, other portions contained energy deposition and timing information. The data sets are amenable to conventional analysis techniques but there is no assurance that conventional techniques make full use of subtle correlations and relations amongst the detector responses. With the advent of neural network technologies, particularly adept at classification of complex phenomena, it would seem appropriate to explore the utility of neural network techniques to classify particles observed with the instruments. In this paper neural network based methodology for signal/background discrimination in a cosmic ray space experiment is discussed. Results are presented for electron and positron classification in the TS93 flight data set and will be compared to conventional analyses.

1995-09-01

443

The BAIKAL Neutrino Experiment: From NT200 to NT200+  

CERN Document Server

The Baikal Neutrino Telescope has been operating in its NT200 configuration since April, 1998. The telescope has been upgraded in April, 2005, to the 10 Mton scale detector NT200+. It's main physics goal is the detection of signals from high energy neutrino cascades. NT200+ reaches a 3-year sensitivity of 2 \\times 10^{-7}cm^{-2}s^{-1}sr^{-1}GeV for an all-flavor diffuse cosmic E^{-2} neutrino flux for energies 10^2 TeV \\div 10^5 TeV. Desgin and sensitivity of NT200+ are described. NT200+ is forming the basic building block of a future km3-scale (Gigaton-Volume) Baikal Telescope. Research and development work on that next stage detector has started.

2006-01-01

444

Tachyons and experimental physics  

International Nuclear Information System (INIS)

An experimentalist looking for free tachyons is faced with the following two related problems: A) How does a tachyon interact with bradyonic matter. Is it an object more or less localized in space-time. B) How should a (bradyonic) detector for tachyons look. To answer B) you should necessarily know something about A). But a theory which provides sufficient information doesn't exist at the moment. Therefore it is necessary to make some simple assumption to tackle problem B). In the second part of this contribution two possibilities of tachyon detectors are proposed assuming that a free charged tachyon (if it exists) exhibits normal electromagnetic interaction with bradyonic matter. Another possibility to look for tachyons produced in high energy reactions of bradyons is the missing mass method using the fact that the four-momentum of a collection of particles can be spacelike if at least one tachyon is present. Such experiments have been ...

445

Study of point defect detectors in Si  

International Nuclear Information System (INIS)

The importance of point defects in semiconductor and function materials has been studied in detail, but effective means for detecting point defects has not been available for a long time. The end of range defects in Si, produced by 140 keV Ge"+ implantation, were investigated as detectors for measuring the interstitial concentration created by 42 keV B"+ implantation. The concentration of interstitial resulting from the B"+ implantation and the behavior of the interstitial flux under different annealing condition were given. The enhanced diffusion in the boron doped EPI marker, resulting from mobile non-equilibrium interstitials was demonstrated to be transient. Interstitial fluxes arising from processing can be detected by transient enhanced diffusion (TED) of doped marker layers as well

1999-05-01

446

Search for tachyons associated with EAS at energies E>=3x10"1"6eV  

International Nuclear Information System (INIS)

This paper describes an experiment which has been performed with a somewhat different philosophy in its approach as compared to previous work. (a) The trigger threshold energy was increased by more than a factor of ten on previous experiments reducing the dilution effect of many lower energy showers known not to produce tachyons. 1673 shower were recorded. (b) The exposure time was made longer than previous experiments in order to obtain a reasonably large statistical sample at the higher threshold. Observations were made between February 1979 and June 1980, the total live time being 9768 hours. (c) Records of the detector output amplitude for the 480#mu#s lead time were integrated point by point as is sometimes done in radio astronomy, this gives the integrated energy deposition within the detector.

447

SENSITIVITY STUDIES FOR AN IN-SITU PARTIAL DEFECT DETECTOR (PDET) IN SPENT FUEL USING MONTE CARLO TECHNIQUES  

Energy Technology Data Exchange (ETDEWEB)

This study presents results from Monte Carlo radiation transport calculations aimed at characterizing a novel methodology being developed to detect partial defects in Pressurized Water Reactor (PWR) spent fuel assemblies (SFAs). The methodology uses a combination of measured neutron and gamma fields inside a spent fuel assembly in an in-situ condition where no movement of the fuel assembly is required. Previous studies performed on single isolated assemblies resulted in a unique base signature that would change when some of the fuel in the assembly is replaced with dummy fuel. These studies indicate that this signature is still valid in the in-situ condition enhancing the prospect of building a practical tool, Partial Defect Detector (PDET), which can be used in the field for partial defect detection.

2008-04-28

448

Results from Amanda  

Energy Technology Data Exchange (ETDEWEB)

In this report we present an update on the results from the Amanda-B10 detector which operated in 1997 at depths of 1500 to 2000 meters in the deep Antarctic ice. The goal of Amanda project is to search for extra-terrestrial neutrinos. As a precursor to such a search we have studied atmospheric neutrinos which act as a calibration source for the detector. The observation of atmospheric neutrinos at a rate consistent with Monte-Carlo predictions establishes Amanda-B10 as a neutrino telescope. The Amanda-B10 data has been searched for evidence of several classes of neutrinos and for magnetic monopoles. Searches for a diffuse high energy neutrino flux and for neutrinos in coincidence with gamma-ray bursts have been conducted. Preliminary data analyses show no excess of neutrinos has been found. (A.C.)

2001-07-01

449

Radon diffusion studies through building construction materials using solid state nuclear track detectors  

International Nuclear Information System (INIS)

Radon appears mainly by diffusion processes from the point of origin following #alpha#- decay of "2"2"6Ra in underground soil and building materials used, in the construction of floors, walls, and ceiling. The transport phenomenon of radon through diffusion is a significant contributor to indoor radon entry. In the present study radon diffusion through sand, cement, mixtures of sand + cement (1:1), sand + cement (2:1), sand + cement (3:1), sand + cement (4:1) has been carried out using LR-115 type II solid state nuclear track detectors (SSNTDs). The radon diffusion coefficient and diffusion lengths have been calculated for different materials. The effect of compaction, which changes the porosity and permeability of the materials, on radon diffusion has also been studied. (author)

2003-10-16

450

Quantification of thin film crystallographic orientation using X-ray diffraction with an area detector  

Energy Technology Data Exchange (ETDEWEB)

As thin films become increasingly popular (for solar cells, LEDs, microelectronics, batteries), quantitative morphological information is needed to predict and optimize the film's electronic, optical and mechanical properties. This quantification can be obtained quickly and easily with X-ray diffraction using an area detector and synchrotron radiation in two simple geometries. In this paper, we describe a methodology for constructing complete pole figures for thin films with fiber texture (isotropic in-plane orientation). We demonstrate this technique on semicrystalline polymer films, self-assembled nanoparticle semiconductor films, and randomly-packed metallic nanoparticle films. This method can be immediately implemented to help understand the relationship between film processing and microstructure, enabling the development of better and less expensive electronic and optoelectronic devices.

2010-02-19

451

Progress Report Towards the ICANOE Detector  

CERN Document Server

We present a proposal for a combined ICARUS & NOE general purpose detector, to be installed in Hall B of the Gran Sasso Laboratory.The main scientific goal is the one of elucidating in a comprehensive way the pattern of neutrino $9 masses and mixings, following both (1) the S-KAM results and (2) the predictions on atmospheric neutrinos of the large solution of the Solar Neutrinos deficit. To achieve these goals, the experimental method is based upon the $9 complementary and simultaneous detection of CERN beam (CNGS) and cosmic ray (CR) events. This is made possible because of the complete isotropy of the detection technique. For the currently allowed values of the S-KAM results, both $9 CNGS and cosmic ray data will give independent measurements and provide a precise $(sin^{2}2\\theta; \\Delta m^{2})$ determination rather than a wide band of allowed values. Since we can observe and unambiguously identify $9 $\

1999-01-01

452

Programmable radionuclide X-ray fluorescence multi-channel spectrometric analyzer, type 123-1  

International Nuclear Information System (INIS)

The whole equipment consists of three separate portable parts: a detector case, a microprocessor and a graphic TV monitor. Magnetic tape memory and an x-y recorder can be connected for recording the measured spectra. The analyzer contains two built-in exchangeable excitation radionuclides. Fluorescence and scattered radiation is detected using a proportional detector. The detected pulses are analyzed by a 256-channel analyzer and the results are shown on the display. The device may be used in mining laboratories, coal and ore dressing plant control rooms or in mining fields of open cast mines for quick detection of the quality of mined or dressed raw materials. (E.S.). 1 fig.

1988-01-01

453

Procedure for radiation dose control in irradiated tissues during electron-beam therapy  

International Nuclear Information System (INIS)

The invention refers a procedure of radiation dose control in irradiated tissues during electron-beam therapy. It aims at meeting the planned radiation dose for diseased tissues and taking care of the healthy ones. Therefore, the dose distribution required is determined before irradiation in consideration of such factors as energy-dependence of detector sensitivity, self-absorption within the tissue, and relative biological effectiveness. Furthermore, the expected intensity distribution of secondary quantum radiation excited in the irradiated tissue is calculated. A radiation detector for local resolution is used for registration. During irradiation the calculated intensity distribution is compared with the measured one. The invention is applicable in radiation therapy with monoenergetic electron beams.

1984-11-08

454

Possible applications of plasma lens in high energy physics  

Energy Technology Data Exchange (ETDEWEB)

The concept of the self-focusing plasma lens in various beam-plasma interaction regimes is reviewed. We found that in order for current neutralization to occur, it is only necessary to attain the condition {ital k}{sub {ital p}}{sigma}{sub {ital x}}{approx_gt}1, and not {ital k}{sub {ital p}}{sigma}{sub {ital y}}{approx_gt}1, for flat beams. This helps to substantially reduce the required plasma density for beamstrahlung suppression. We also report on a recent calculation on the detector backgrounds induced by a plasma lens. It is shown that these backgrounds are within the tolerance of all major components in a NLC-like detector. Finally, one other potential application of plasma lens for {gamma}{gamma} colliders is discussed.{copyright}{ital American Institute of Physics.}

1996-01-01

455

Possible applications of plasma lens in high energy physics  

International Nuclear Information System (INIS)

The concept of the self-focusing plasma lens in various beam-plasma interaction regimes is reviewed. We found that in order for current neutralization to occur, it is only necessary to attain the condition k_p#sigma#_x approx-gt 1, and not k_p#sigma#_y approx-gt 1, for flat beams. This helps to substantially reduce the required plasma density for beamstrahlung suppression. We also report on a recent calculation on the detector backgrounds induced by a plasma lens. It is shown that these backgrounds are within the tolerance of all major components in a NLC-like detector. Finally, one other potential application of plasma lens for #gamma##gamma# colliders is discussed.copyright American Institute of Physics.

456

Performance of a Bragg curve detector for heavy ion identification  

Energy Technology Data Exchange (ETDEWEB)

By using Bragg curve spectroscopy, one can measure atomic number and energy of high energy heavy ions stopping in a gas-filled ionization chamber with longitudinal electric field. In this paper, we report on the results obtained with an isobutane filled detector. An energy resolution of 0.8% fwhm and a Z resolution of 2.7% fwhm were achieved for elastically scattered 300 MeV /sup 40/Ar ions. We study the Bragg peak amplitude dependence on the energy of the incoming ions, a dependence presumably due to the Frisch grid screening inefficiency. The corrected Bragg peak spectrum of inelastically scattered 300 MeV /sup 40/Ar ions exhibits a satisfactory Z separation around Z = 18.

1982-12-15

457

Performance of a Bragg curve detector for heavy ion identification  

International Nuclear Information System (INIS)

By using Bragg curve spectroscopy, one can measure atomic number and energy of high energy heavy ions stopping in a gas-filled ionization chamber with longitudinal electric field. In this paper, we report on the results obtained with an isobutane filled detector. An energy resolution of 0.8% fwhm and a Z resolution of 2.7% fwhm were achieved for elastically scattered 300 MeV "4"0Ar ions. We study the Bragg peak amplitude dependence on the energy of the incoming ions, a dependence presumably due to the Frisch grid screening inefficiency. The corrected Bragg peak spectrum of inelastically scattered 300 MeV "4"0Ar ions exhibits a satisfactory Z separation around Z = 18. (orig.).

458

Non-standard antineutrino interactions at Daya Bay  

CERN Document Server

We study the prospects of pinning down the effects of non-standard antineutrino interactions in the source and in the detector at the Daya Bay neutrino facility. It is well known that if the non-standard interactions in the detection process are of the same type as those in the production, their net effect can be subsumed into a mere shift in the measured value of the leptonic mixing angle theta_13. Relaxing this assumption, the ratio of the antineutrino spectra measured by the Daya Bay far and near detectors is distorted in a characteristic way, and good fits based on the standard oscillation hypothesis are no longer viable. We show that, under certain conditions, three years of Daya Bay running can be sufficient to provide a clear hint of non-standard neutrino physics.

2011-01-01

459

Measurement of W{sup {+-}} boson mass at LEP by means of DELPHI detector; Mesure de la masse des bosons W{sup {+-}} au LEP a l`aide du detecteur DELPHI  

Energy Technology Data Exchange (ETDEWEB)

The thesis deals with measurement of the mass of the W boson at LEP2, based on the direct reconstruction of its decay products in the hadronic channel. A set of procedures necessary for the extraction of the W mass from the experimental data collected with the DELPHI detector in 1997 was developed (search of optimal variables for the event selection, development of a special method of kinematical reconstruction). The measured value of the mass was interpreted in the framework of the Standard Model, allowing to constrain the mass of the Higgs boson. A substantial part of the work is devoted to systematic effects due to the interactions between the hadronic decay products of the W bosons (colour reconnection and Bose-Einstein correlations), which may significantly influence the measurement of their mass. (author) 53 refs., 104 figs., 33 tabs.

1998-05-25

460

Low-dose contrast protocol using the test bolus technique for 64-detector computed tomography coronary angiography  

British Library Electronic Table of Contents (United Kingdom)

Purpose We evaluated low-contrast injection protocols for coronary computed tomography angiography (CTA) using a 64-detector scanner and the test bolus technique. Materials and methods We randomly assigned 60 patients undergoing coronary CTA to one of two contrast material (CM) injection protocols. For the lowcontrast dose protocol (Plow), the patients received injections of iohexol-350 [0.7 ml/kg body weight (BW)] during 9 s, and the test-bolus technique was used. Under the conventional protocol (Pconv), they received iohexol-350 (1.0 ml/kg BW) during 15 s, and bolus tracking was used. We compared the protocols for attenuation values in the ascending aorta and coronary arteries and for the amount of CM required. Results There was no significant difference in the mean CT attenuation of the...

2011-01-01

461

Linac automated beam phase control system.  

Energy Technology Data Exchange (ETDEWEB)

Adjustment of the rf phase in a linear accelerator is crucial for maintaining optimal performance. If phasing is incorrect, the beam will in general have an energy error and increased energy spread. While an energy error can be readily detected and corrected using position readings from beam position monitors at dispersion locations, this is not helpful for correcting energy spread in a system with many possible phase errors. Uncorrected energy spread results in poor capture efficiency in downstream accelerators, such as the Advanced Photon Source's (APS's) particle accumulator ring (PAR) or booster synchrotron. To address this issue, APS has implemented beam-to-rf phase detectors in the linac, along with software for automatic correction of phase errors. We discuss the design, implementation, and performance of these detectors and how they improved APS top-up operations.

2006-01-01

462

Information flow, causality, and the classical theory of tachyons  

International Nuclear Information System (INIS)

Causal paradoxes arising in the tachyon theory have been systematically solved by using the reinterpretation principle as a consequence of which cause and effect no longer retain an absolute meaning. However, even in the tachyon theory, a cause is always seen to chronologically precede its effect, but this is obtained at the price of allowing cause and effect to be interchanged when required. A recent result has shown that this interchange-ability of cause and effect must not be unlimited if heavy paradoxes are to be avoided. This partial recovery of the classical concept of causality has been expressed by the conjecture that transcendent tachyons cannot be absorbed by a tachyon detector. In this paper the directional properties of the flow of information between two observers in relative motion and its consequences on the logical self-consistency of the theory of superluminal particles are analyzed. It is shown that the above conjecture does not provide a ...

463

Gas sensor arrays (electronic noses) and their combination with trap techniques  

Energy Technology Data Exchange (ETDEWEB)

In the food, chemical and safety industry there is a demand for gas detectors for process control applications, like quality control of food or leakage control in chemical plants. Gas sensor array systems have the potential to be used in this areas, with the advantage of being also affordable systems compared to other systems like gaschromatographs (GC) or infrared detectors (NIR, FTIR). One of the main drawbacks of the gas sensors is their response to non interesting ambient factors like temperature, pressure and humidity. Metal oxide sensors (MOS) have a low ambient temperature and pressure dependency. Some of them (SnO + dopands) have some sensitivity to humidity. In many cases the response of the sensors is often non-linear, which implies a concentration dependant pattern of the samples. (orig.)

2001-07-01

464

Gamma-rays and neutrinos from the pulsar wind nebulae  

Energy Technology Data Exchange (ETDEWEB)

We construct the time-dependent radiation model for the pulsar wind nebulae (PWNe), assuming that leptons are accelerated in resonant scattering with heavy nuclei, which are injected into the nebula by the pulsar. The equilibrium spectra of these particles inside the nebula are calculated taking into account their radiation and adiabatic energy losses. The spectra of {gamma}-rays produced by these particles are compared with the observations of the PWNe emitting TeV {gamma}-rays and predictions are made for the expected {gamma}-ray fluxes from other PWNe. Expected neutrino fluxes and neutrino event rates in a 1 km{sup 2} neutrino detector from these nebulae are also calculated. It is concluded that only the Crab Nebula can produce a detectable neutrino event rate in the 1 km{sup 2} neutrino detector. Other PWNe can emit TeV {gamma}-rays on the level of a few percent of that observed from the Crab Nebula.

2005-08-01

465

Explosives detector  

Energy Technology Data Exchange (ETDEWEB)

An apparatus for non-invasively inspecting an object, such as an item of luggage, for explosives material is described. It comprises a multi-channel thermal neutron inspection system having a plurality of neutron irradiation chambers. Simultaneous operation of several channels increases the maximum system throughput several times. Each chamber has a lithium neutron source which is stimulated to neutron production by a proton beam. Beam switching magnets are energised by pulsing to divert a common proton beam to each source in turn. The initial beam is generated by a radio frequency quadrupole accelerator. The advantages of this system are very low residual source activity and controllable neutron production thereby minimising safety hazards. The irradiation chamber may contain several different gamma ray detectors to identify the elements present in explosives material. In addition, a neutron radiography imaging means may be employed to identify the presence of ...

1991-10-02

466

Experimental limits on quarks, tachyons, and massive particles in cosmic rays  

Energy Technology Data Exchange (ETDEWEB)

A large detector with high redundancy is used to search for various types of anomalous particles in cosmic rays at sea level. The detector is sensitive to zenith angles between 45/sup 0/ and 90/sup 0/. Previously obtained limits on the fluxes of charge (1/3) and (2/3) particles are reduced to 2.9 x 10/sup -10/ and 2.6 x 10/sup -10/ cm/sup -2/sr /sup -1/ sec/sup -1/, respectively. The flux of ionizing tachyons is determined to be less than 2.4 x 10/sup -9/ cm/sup -2/ sr/sup -1/ sec/sup -1/. The massive-particle flux limit we obtain is inconsistent with previous claims of such particles assuming that these particles are isotropic in zenith angle.

1982-10-01

467

Experimental limits on quarks, tachyons, and massive particles in cosmic rays  

International Nuclear Information System (INIS)

A large detector with high redundancy is used to search for various types of anomalous particles in cosmic rays at sea level. The detector is sensitive to zenith angles between 45"0 and 90"0. Previously obtained limits on the fluxes of charge (1/3) and (2/3) particles are reduced to 2.9 x 10"-"1"0 and 2.6 x 10"-"1"0 cm"-"2sr "-"1 sec"-"1, respectively. The flux of ionizing tachyons is determined to be less than 2.4 x 10"-"9 cm"-"2 sr"-"1 sec"-"1. The massive-particle flux limit we obtain is inconsistent with previous claims of such particles assuming that these particles are isotropic in zenith angle.

468

Empirical relationship between track diameter and etching time for fission fragments incident on a glass SSNTD at various angles of incidence  

Energy Technology Data Exchange (ETDEWEB)

Geometrical shapes and diameter of nuclear tracks changes continuously during the process of etching for various incident angles. Besides, there is also a marked difference amongst their profiles, as evidenced by the SEM analysis, when the incoming particles fall on the detector at different angles of incidence. This work outlines this aspect of fission fragment tracks in a glass detector and has set out a few empirical relationships between the mean track diameter, d-bar and the etching time, t, within experimental limits. This study, therefore, sheds some light in the follow up the origins and characteristics of heavy ions in some terrestrial and extra-terrestrial materials and also in studying the collimation accuracy of heavy ion bombardments. The implications of the results in discerning the measurements of incident angles of various types of ions are described in detail in the paper.

1983-09-01

469

Discriminating between a Stochastic Gravitational Wave Background and Instrument Noise  

CERN Document Server

The detection of a stochastic background of gravitational waves could significantly impact our understanding of the physical processes that shaped the early Universe. The challenge lies in separating the cosmological signal from other stochastic processes such as instrument noise and astrophysical foregrounds. One approach is to build two or more detectors and cross correlate their output, thereby enhancing the common gravitational wave signal relative to the uncorrelated instrument noise. When only one detector is available, as will likely be the case with the Laser Interferometer Space Antenna (LISA), alternative analysis techniques must be developed. Here we show that models of the noise and signal transfer functions can be used to tease apart the gravitational and instrument noise contributions. We discuss the role of gravitational wave insensitive "null channels" formed from particular combinations of the time delay interferometry, and ...

2010-01-01

470

Determination of radon and thoron permeability through some plastics by track technique  

Energy Technology Data Exchange (ETDEWEB)

Experiments have been performed to study the usefulness of several types of plastic foils as filter to separate radon and thoron. Time-integrated alpha-activity measurements have been carried out by using the so-called ''can-technique'' equipped with both LR-115 and CR-39 track detectors. The track density observed on the detectors, taken as a measure of radon activity concentration, has been determined as a function of the thickness of filter foils. The radon permeability and the thoron separation factors have been determined. It is shown that various plastic foils exhibit considerable differences in radon diffusion coefficient owing to their different chemical structures. Among the plastic foils investigated the polyethylene proved to have the highest gas diffusion coefficient.

1986-01-01

471

Conceptual design of a low-temperature radiation-hard tracker detector  

CERN Document Server

Silicon sensors have about ten times improved radiation hardness around 130 K temperature, compared with the state-of-art sensors close to room temperature. This is based on the Lazarus effect studied by the RD39 Collaboration of CERN. Other benefits of low temperatures will also be discussed. We shall describe the conceptual design of low-mass detector modules cooled using two-phase flow of argon in miniature cooling pipes integrated in the module structure between the sensors and the readout hybrid circuit. The main engineering features of the cooling system and mechanical support structures are discussed, as well as the benefits arising from the operation of the tracker under cryogenic vacuum. 4 Refs.

2003-01-01

472

Comparison of energy flows in deep inelastic scattering events with and without a large rapidity gap  

Energy Technology Data Exchange (ETDEWEB)

Energy flows in deep inelastic electron-proton scattering are investigated at a centre-of-mass energy of 296 GeV for the range Q{sup 2}{>=}10 GeV{sup 2} using the ZEUS detector. A comparison is made between events with and without a large rapidity gap between the hadronic system and the proton direction. The energy flows, corrected for detector acceptance and resolution, are shown for these two classes of events in both the HERA laboratory frame and the Breit frame. From the differences in the shapes of these energy flows we conclude that QCD radiation is suppressed in the large-rapidity-gap events compared to the events without a large rapidity gap. (orig.)

1994-07-01

473

Circumsolar radiation telescope  

Energy Technology Data Exchange (ETDEWEB)

A circumsolar telescope for determining the flux of energy from the sun and from the circumsolar region as a function of angle, wavelength, and atmospheric conditions is presented. The telescope system consists of a specially designed scanning telescope, an electronic control and recording system and some auxiliary equipment. The detector is a pyroelectric crystal, a type of thermal detector, thus the fundamental measurement is relatively wavelength insensitive. The telescope is designed to provide data for all weather conditions during which a concentrating solar energy system would be operating. Analyses show that for a clear blue sky, the amount of radiation coming directly from the sun, while for a sky with thin clouds or haze, the circumsolar radiation is some 25% of the direct solar radiation. Under such conditions a measure of the circumsolar radiation is necessary for an accurate prediction of the performance of a concentrating solar ...

1980-01-01

474

Apparatus for in situ determination of burnup cooling time and fissile content of an irradiated nuclear fuel assembly in a fuel storage pond  

Energy Technology Data Exchange (ETDEWEB)

A detector head for in situ inspection of irradiated nuclear fuel assemblies submerged in a water-filled nuclear fuel storage pond. The detector head includes two parallel arms which extend from a housing and which are spaced apart so as to be positionable on opposite sides of a submerged fuel assembly. Each arm includes an ionization chamber and two fission chambers. One fission chamber in each arm is enclosed in a cadmium shield and the other fission chamber is unshielded. The ratio of the outputs of the shielded and unshielded fission chambers is used to determine the boron content of the pond water. Correcting for the boron content, the neutron flux and gamma ray intensity are then used to verify the declared exposure, cooling time and fissile material content of the irradiated fuel assembly.

1985-04-09

475

An improved noise-robust voice activity detector based on hidden semi-Markov models  

British Library Electronic Table of Contents (United Kingdom)

To improve the performance of voice activity detector (VAD) in noisy environments, this paper concentrates on three critical aspects related to noise robustness including speech features, feature distributions and temporal dependence. Based on the statistic on TIMIT and NOIZEUS, Mel-frequency cepstrum coefficients (MFCCs) are selected as speech features, Gaussian Mixture distributions (GMD) are applied to associate the observations in MFCC domain with both speech and non-speech states, and Weibull and Gamma distributions are used to explicitly model noise and speech durations, respectively. To integrate these aspects into VAD, the hidden semi-Markov model (HSMM) as a generalized hidden Markov model (HMM) is introduced first. Then the VAD decision is made according to the likelihood ratio t...

2011-01-01

476

A search for resonant Z pair production  

Energy Technology Data Exchange (ETDEWEB)

I describe a search for anomalous production of Z pairs through a new massive resonance X in 2.5-2.9 fb{sup -1} of p{bar p} collisions at {radical}s = 1.96 TeV using the CDFII Detector at the Fermilab Tevatron. I reconstruct Z pairs through their decays to electrons, muons, and quarks. To achieve perhaps the most efficient lepton reconstruction ever used at CDF, I apply a thorough understanding of the detector and new reconstruction software heavily revised for this purpose. In particular, I have designed and employ new general-purpose algorithms for tracking at large {eta} in order to increase muon acceptance. Upon analyzing the unblinded signal samples, I observe no X {yields} ZZ candidates and set upper limits on the production cross section using a Kaluza-Klein graviton-like acceptance.

2008-12-01

477

Temporal variations of radon in soil related to earthquakes  

Energy Technology Data Exchange (ETDEWEB)

A radon detector with LR-115 nuclear track film was constructed for radon concentration measurements in soil. Temporal radon variations, as well as the barometric pressure, precipitation and temperature were measured for two years. Negative correlation between radon concentration in soil and barometric pressure was found. For some of the recorded earthquakes that occurred during the observation period, soil radon anomalies may be noticed one month before the quakes.

2001-08-01

478

Rayleigh Scattering in Rare Gas Liquids  

CERN Document Server

The Rayleigh scattering length has been calculated for rare-gas liquids in the ultraviolet for the frequencies at which they luminesce. The calculations are based on the measured dielectric constants in the gas phase, except in the case of xenon for which measurements are available in the liquid. The scattering length mayplace constraints on the design of some large-scale detectors, using uv luminescence, being proposed to observe solar neutrinos and dark matter. Rayleigh scattering in mixtures of rare-gas mixtures is also discussed.

2002-01-01

479

Radon measurements in the interior of the great pyramid  

Energy Technology Data Exchange (ETDEWEB)

Radon concentration measurements were made in the interior of the great pyramid of ''Cheops'' at Giza. Measurements were carried out using CR-39 as a solid state nuclear track detector. The CR-39 sheets were placed inside the Queen's and King's chambers and along the ascending corridor leading to them. An evaluation of the radon concentration is presented and discussed. (author).

1991-01-01

480

Radon measurements in the interior of the great pyramid  

International Nuclear Information System (INIS)

Radon concentration measurements were made in the interior of the great pyramid of ''Cheops'' at Giza. Measurements were carried out using CR-39 as a solid state nuclear track detector. The CR-39 sheets were placed inside the Queen's and King's chambers and along the ascending corridor leading to them. An evaluation of the radon concentration is presented and discussed. (author).

481

Radial distribution of dose and cross-sections for the inactivation of dry enzymes and viruses  

International Nuclear Information System (INIS)

A new semi-empirical algorithm for the radial distribution of dose is compared with available data. The algorithm is used to calculate the inactivation cross section for dry enzymes and viruses using an extended target model of a 1-hit detector. Agreement with data is at about the 15% level, approximating the precision of the data itself. (author).

1985-05-01

482

P and e identification capabilities CAPRICE  

Energy Technology Data Exchange (ETDEWEB)

The cosmic antiparticle ring imaging Cherenkov experiment (CAPRICE) flew on a stratospheric balloon 8-9 August 1994 over northern Canada and collected data for more than 21 hours with less than 5 g/cm{sup 2} of residual atmosphere. The instrument includes a solid radiator RICH detector and an electromagnetic calorimeter for particle identification in the magnetic spectrometer. Preliminary antiproton and positron identification capabilities are presented.

1995-09-01

483

Operation and physics potential of Tevatron Run 2  

Energy Technology Data Exchange (ETDEWEB)

The Tevatron Run 2 has begun. The Tevatron program in the next six years offers a real opportunity to significantly advance our understanding of the fundamental properties of the universe. It is an exciting, challenging program that goes straight to the highest priorities of high energy physics worldwide. The accelerator and detectors are being commissioned and seem to be performing well. We anticipate first physics results in the summer of 2002.

2001-12-07

484

Measuring equipment for the monitoring of air pollution control - a market review  

Energy Technology Data Exchange (ETDEWEB)

The paper abstracted gives a tabular survey of the suppliers and applications of measuring equipment. Equipment is available for the following fields of application: Continuous measuring instruments for stationary operation, laboratory equipment for sampling and hand equipment for mobile measurement, sampling equipment for examining emissions and gases, detectors, storage and evaluation equipment and meteorological instruments. (PW).

1986-01-01

485

LiF:Mg, Cu, P TL detectors with adjustable energy responses  

Energy Technology Data Exchange (ETDEWEB)

When used for tissue-equivalent monitoring, the thermoluminescence material LiF:Mg, Cu, P shows an 'under-response' to low-energy photons. This paper explores a new way to increase its low-energy response effectively, and to make it adjustable to some extent, by adding elements with high Z{sub eff}. At the same time its excellent thermoluminescente (TL) performance is maintained. (author).

1991-11-14

486

LC-MS analysis in the e-beam and gamma radiolysis of metoprolol tartrate in aqueous solution: Structure elucidation and formation mechanism of radiolytic products  

British Library Electronic Table of Contents (United Kingdom)

E-beam and gamma products from the radiolysis of aqueous solutions of (+-)-metoprolol tartrate, saturated in nitrogen, are analyzed by HPLC with on-line mass and UV detectors. The structures of 10 radiolytic products common to e-beam and gamma irradiations are elucidated by comparing their fragmentation pattern to that of (+-)-metoprolol. Two of the radiolytic products are also metabolites. Different routes for the formation of the radiolytic products are proposed.

2006-01-01

487

Josephson junctions as heterodyne detectors  

International Nuclear Information System (INIS)

Heterodyne detection with a point-contact Josephson junction has been investigated both experimentally and theoretically. The measured performance of the device at 36 GHz is in good agreement with the theory. By operating vanadium point contacts at 1.4 K, the authors have achieved a single-sideband (SSB) mixer noise temperature of 54 K with a conversion gain of 1.35 and a signal bandwidth on the order of 1 GHz. A potentially impressive performance for these devices at submillimeter wavelengths can be extrapolated from the results.

488

In-beam conversion electron spectroscopy using the SACRED array  

International Nuclear Information System (INIS)

Conversion electron studies of medium-heavy to heavy nuclear mass systems are important where the internal conversion process begins to dominate over gamma-ray emission. The use of a segmented detector array sensitive to conversion electrons has been used to study multiple conversion electron cascades from nuclear transitions. The application of the silicon array for conversion electron detection (SACRED) for in-beam measurements has successfully been implemented. (orig.). With 2 figs.

489

Impact of computers in radiography: the advent of digital radiography, part-2  

International Nuclear Information System (INIS)

Computed radiography (CR) systems use a photostimulable phosphor plate enclosed in a cassette. In CR, image acquisition is a two-stage process wherein image capture and image read out are done separately. Direct digital radiography (DR) systems, on the other hand, use detectors that have a combined image capture and image read out capability. DR systems are also called as DDR or ddR systems by some vendors. This article focuses on DR systems

2008-08-01

490

Gamma spectrometry calibrations with natural radioactive materials  

Energy Technology Data Exchange (ETDEWEB)

Natural radioactive materials were used for detector calibration. We found that KCl is a very suitable material for this purpose. The efficiency curve shape was derived by using {gamma} ray lines of {sup 214}Bi normalised using a known quantity of KCl in the same geometry. The best fit was found by the least squares method. The summing correction coefficients for {sup 214}Bi are determined. (orig.).

1996-02-01

491

Gamma spectrometry calibrations with natural radioactive materials  

International Nuclear Information System (INIS)

Natural radioactive materials were used for detector calibration. We found that KCl is a very suitable material for this purpose. The efficiency curve shape was derived by using #gamma# ray lines of "2"1"4Bi normalised using a known quantity of KCl in the same geometry. The best fit was found by the least squares method. The summing correction coefficients for "2"1"4Bi are determined. (orig.).

492

Feasibility of /sup 252/Cf source driven neutron noise measurements in water moderated reactors  

Energy Technology Data Exchange (ETDEWEB)

Previous experiments in fast critical assemblies demonstrated a method of determining reactivity from power spectral density measurements with /sup 252/Cf. This method determines reactivity from properties of the reactor only at the subcritical state of interest, thus it does not require a calibration near delayed criticality. The interpretation of the measured data to obtain reactivity does not require knowledge of the relative or absolute values of the source intensity, knowledge of the detection efficiencies, or knowledge of the detection instrumentation frequency responses. An experiment was performed at the Pool Critical Assembly to evaluate the possibility of /sup 252/Cf source driven neutron noise spectral density measurements in light water moderated reactors. This experiment showed that using commercially available detectors, such measurements can be performed in a reasonable time, that is, the measurement of the quantity of interest (the ratio of spectral ...

1980-01-01

493

Determination of efficiency curves of germanium detectors using natural radioactive materials  

International Nuclear Information System (INIS)

Efficiency calibration curves for different densities and geometries are necessary for activity determination of various environmental samples. Commercially available standards or natural radioactive materials are used for calibration. Potassium compounds are especially suitable, since they can be mixed with unknown samples. It is possible to determine efficiency curve and unknown activity of sample knowing "4"0 K activity. (author).

494

Cylindrical drift chamber with three-dimensional data readout  

International Nuclear Information System (INIS)

A multiwire cylindrical drift chamber is the main detector of the AMPIR 4#pi#-spectrometer for studying pion-nucleon reactions. The chamber has possibility to measure three coordinates by the electron drift time and by the charge division method. Chamber design and geometry, test bench, readout electronics and also results of calculations, simulation and tests are described.

495

Cylinder drift chamber with three-dimensional data output  

Science.gov (United States)

A cylindrical multiwire drift chamber is the central detector of the AMPIR spectrometer. It has 4{pi} acceptance angle and was designed to study pion-nucleon reactions. The chamber can determine the three coordinates through the electron drift time and charge division ration. The paper describes the layout and design of the chamber, the test bench, the data output circuit, the design parameters, and the results of computer simulations and tests.

1995-03-01

496

Cylinder drift chamber with three-dimensional data output  

International Nuclear Information System (INIS)

A cylindrical multiwire drift chamber is the central detector of the AMPIR spectrometer. It has 4#pi# acceptance angle and was designed to study pion-nucleon reactions. The chamber can determine the three coordinates through the electron drift time and charge division ration. The paper describes the layout and design of the chamber, the test bench, the data output circuit, the design parameters, and the results of computer simulations and tests.

497

Core power distribution measurement and data processing in Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

For the first time in China, Daya Bay Nuclear Power Station applied the advanced technology of worldwide commercial pressurized reactors to the in-core detectors, the leading excore six-chamber instrumentation for precise axial power distribution, and the related data processing. Described in this article are the neutron flux measurement in Daya Bay Nuclear Power Station, and the detailed data processing.

498

ATLAS tile calorimeter electronics upgrade  

CERN Document Server

This presentation summarizes the present upgrade R&D projects in the TileCal collaboration. One project studies the possibility to divide the drawers into smaller minidrawers to simplify maintenance. There are three different front-end projects. There are also projects dealing with high voltage and low voltage distribution, projects for developing PMT dividers, low voltage electronics, data transmission and off-detector electronics.

2011-01-01