Energy Technology Data Exchange (ETDEWEB)
The original objective of our EMSP research was to design, develop, and test new in situ field permeameters for use in spatial variability studies of unsaturated hydraulic properties. We initially focused on activities related to development and testing of techniques for inverting permeameter data, development of numerical tools for data inversion, error evaluation for permeameter design, and permeameter component design. However, the results of error evaluations for permeameter design caused us to redirect our research, and reformulate our research objectives. We discovered that small, simple measurement errors lead to significant bias in the estimated hydraulic properties and their spatial statistics. Our reformulated research objective became the evaluation of the origin, impact and relevance of spatial bias in field-and laboratory-estimated unsaturate hydraulic properties, with ...
2001-12-01
Reduction of statistic error in Mihalczo subcriticality measurement
Energy Technology Data Exchange (ETDEWEB)
The theoretical formula for the statistical error estimation in Mihalczo method was derived, and the dependence of the error were investigated on the facility to be measured and on the parameter in the data analysis. The formula was derived based on the reactor noise theory and the error theory for the frequency analysis, and found that the error depends on such parameters as the prompt neutron decay constant, detector efficiencies, and the frequency bandwidth. Statistical errors estimated with the formula was compared with experimental values and verified to be reasonable. Through parameter surveys, it is found that there is an optimum combination of the parameters to reduce the magnitude of the errors. In the experiment performed in DCA subcriticality measurement facility, it is estimated experimentally that the ...
1998-08-01
Optimal alignment of mirror based pentaprisms for scanning deflectometric devices
In the recent work [Proc. of SPIE 7801, 7801-2/1-12 (2010), Opt. Eng. 50(5) (2011), in press], we have reported on improvement of the Developmental Long Trace Profiler (DLTP), a slope measuring profiler available at the Advanced Light Source Optical Metrology Laboratory, achieved by replacing the bulk pentaprism with a mirror based pentaprism (MBPP). An original experimental procedure for optimal mutual alignment of the MBPP mirrors has been suggested and verified with numerical ray tracing simulations. It has been experimentally shown that the optimally aligned MBPP allows the elimination of systematic errors introduced by inhomogeneity of the optical material and fabrication imperfections of the bulk pentaprism. In the present article, we provide the analytical derivation and verification of easily executed optimal alignment algorithms for two different designs of mirror based pentaprisms. We also provide an analytical ...
2011-03-04
Some sources of error in property indices for coke-oven charge
The author points out that errors in certain measurements are preventing improvements in coke: thermocouples (errors caused by the thermocouple installation and variations in the temperature of the cold junctions); dilatometers (errors caused by size of heating block and differences in starting temperature led to differences between two instruments); errors in measuring the bulk density of the coking charge. The elimination of these sources of error in determinations of the technological and physical properties of coke oven charge should assist in the study of other problems which are delaying improvements in blast furnace coke production.
1981-01-01
Energy Technology Data Exchange (ETDEWEB)
The consistency of different instruments and methods for measuring two-dimensional (2D) power spectral density (PSD) distributions are investigated. The instruments are an interferometric microscope, an atomic force microscope (AFM) and the X-ray Reflectivity and Scattering experimental facility, all available at Lawrence Berkeley National Laboratory. The measurements were performed with a gold-coated mirror with a highly polished stainless steel substrate. It was shown that these three techniques provide essentially consistent results. For the stainless steel mirror, an envelope over all measured PSD distributions can be described with an inverse power-law PSD function. It is also shown that the measurements can be corrected for the specific spatial frequency dependent systematic errors of the instruments. The AFM and the X-ray scattering ...
2005-07-12
Energy Technology Data Exchange (ETDEWEB)
The consistency of different instruments and methods for measuring two-dimensional (2D) power spectral density (PSD) distributions are investigated. The instruments are an interferometric microscope, an atomic force microscope (AFM) and the X-ray Reflectivity and Scattering experimental facility, all available at Lawrence Berkeley National Laboratory. The measurements were performed with a gold-coated mirror with a highly polished stainless steel substrate. It was shown that these three techniques provide essentially consistent results. For the stainless steel mirror, an envelope over all measured PSD distributions can be described with an inverse power-law PSD function. It is also shown that the measurements can be corrected for the specific spatial frequency dependent systematic errors of the instruments. The AFM and the X-ray scattering ...
2005-04-17
Deep inelastic scattering of leptons on nuclei
International Nuclear Information System (INIS)
Experimental studied of deep-inelastic scattering of neutrino, antineutrino, #mu#-mesons, electron reactions on He, D, Al, Fe, Au, Be, C, Ca, Ag, N nuclei conducted in recent years at different laboratories the world for consideration of modern status of the problems of R(x, Q"2) = #sigma#sub(L)/#sigma#sub(T) parameter variation and for study on nuclear effects in structural functions of nucleons are described in the review. Experimental information on measurements of the R parameter by data on EMS and SLAK groups is analyzed. It is noted that experimental data on measuring R contain essential errors that hampers unambiguous interpretation of data on nucleon structure. Present experimental data and predictions for explanation of the EMS effect are analyzed from the view point of quark and flucton models of a nucleus.
1984-06-19
Neural classifier construction using regularization, pruning and test error estimation.
In this paper we propose a method for construction of feed-forward neural classifiers based on regularization and adaptive architectures. Using a penalized maximum likelihood scheme, we derive a modified form of the entropic error measure and an algebraic estimate of the test error. In conjunction with optimal brain damage pruning, a test error estimate is used to select the network architecture. The scheme is evaluated on four classification problems. PMID:12662736
1998-12-01
Measurement of fast fluctuations of radiation intensity in pulsed charged particle accelerators
International Nuclear Information System (INIS)
... beam monitoring betatrons delay circuits errors fluctuations gamma radiation
Discrepancies in molar extinction coefficients of Fe"3"+ in Fricke dosimetry
International Nuclear Information System (INIS)
Values of the chemical yield, G, and of the molar extinction coefficient, epsilon, for Fricke dosimetry, have been recommended by ICRU. For epsilon, the value in ICRU Reports 17 and 21, 2205 1.mol"-"1.cm"-"1, based on an analysis of 83 reported values. It was suggested that, where neither a careful wavelength calibration nor absorbance linearity checks had been performed, a standard error of 1.5% should be assumed; otherwise 0.15% could be accepted. Alternatively, the accuracy in applying this chemical dose meter was considered improved if there was an independent determination of epsilon with the same spectrophotometer as was used for the determination of the optical density of irradiated Fricke solution. The accuracy claimed for both methods remains questionable, since no complete argumentation could be given for the differences of up to 13% in the published values. Taking into account the discussion of the sources of error by Bryant, ...
1977-12-09
Basic mechanisms of radiation effects in the natural space radiation environment
Energy Technology Data Exchange (ETDEWEB)
Four general topics are covered in respect to the natural space radiation environment: (1) particles trapped by the earth`s magnetic field, (2) cosmic rays, (3) radiation environment inside a spacecraft, (4) laboratory radiation sources. The interaction of radiation with materials is described by ionization effects and displacement effects. Total-dose effects on MOS devices is discussed with respect to: measurement techniques, electron-hole yield, hole transport, oxide traps, interface traps, border traps, device properties, case studies and special concerns for commercial devices. Other device types considered for total-dose effects are SOI devices and nitrided oxide devices. Lastly, single event phenomena are discussed with respect to charge collection mechanisms and hard errors. (GHH)
1994-06-01
International Nuclear Information System (INIS)
The additional error in measurement of the thickness of Kh18N10T steel for possible changes in composition with an energy of the photons of ionizing radiation of 10-80 keV was evaluated. The desirability of use of a type REIS-I x-ray emitter in measurement of the thickness of steel up to 1 mm is shown. The instrument provides measurement of the thickness of steel in the 0.1-1.0 mm range with a reproducibility of the results with an error not exceeding 0.5-1.0%. The measurement error with corrugations characteristic of bellows does not exceed 5%.
Dynamic and static error analyses of neutron radiography testing
Energy Technology Data Exchange (ETDEWEB)
Neutron radiography systems are being used for real-time visualization of the dynamic behavior as well as time-averaged measurements of spatial vapor fraction distributions for two phase fluids. The data in the form of video images are typically recorded on videotape at 30 frames per second. Image analysis of he video pictures is used to extract time-dependent or time-averaged data. The determination of the average vapor fraction requires averaging of the logarithm of time-dependent intensity measurements of the neutron beam (gray scale distribution of the image) that passes through the fluid. This could be significantly different than averaging the intensity of the transmitted beam and then taking the logarithm of that term. This difference is termed the dynamic error (error in the time-averaged vapor fractions due to the inherent time-dependence of the measured data) and is ...
1999-03-01
Human error and experienced feedback during refuelling overhauling of Daya Bay Nuclear Power Station
International Nuclear Information System (INIS)
The authors describe the various human error encountered during Daya bay refueling overhaul, and the subsequent root cause evaluation and protective measure. Authors consider transparency is the key in reducing human error and event recurrence. Additional y, event transparency will enhance the effectiveness if experience feedback and reduce event consequence
2000-10-01
Measurement of the parity violating asymmetry A{sub {gamma}} in n{yields}+p{yields}d+{gamma}
Energy Technology Data Exchange (ETDEWEB)
The weak interaction between neutrons and protons has never been resolved experimentally. In analogy with the strong NN interaction, the weak NN interaction at low energy can be parametrized in terms of a meson exchange model with parity violating meson-nucleon couplings. Unlike the measured proton-proton weak interaction, the neutron-proton weak interaction is sensitive to the weak pion-nucleon coupling constant H{sub {pi}}{sup 1}. This coupling, which is responsible for the longest-ranged part of the weak NN interaction and is therefore an essential part of any description of weak interactions in nuclei, remains undetermined despite many years of effort. A measurement of the gamma ray directional asymmetry A{sub {gamma}} in the capture of polarized neutrons by parahydrogen has been proposed at Los Alamos National Laboratory. The goal of this experiment is to determine A{sub {gamma}} with a relative standard uncertainty of ...
2000-02-11
Typically, point forecasting methods are compared and assessed by means of an error measure or scoring function, such as the absolute error or the squared error. The individual scores are then averaged over forecast cases, to result in a summary measure of the predictive performance, such as the mean absolute error or the (root) mean squared error. I demonstrate that this common practice can lead to grossly misguided inferences, unless the scoring function and the forecasting task are carefully matched. Effective point forecasting requires that the scoring function be specified ex ante, or that the forecaster receives a directive in the form of a statistical functional, such as the mean or a quantile of the predictive distribution. If the scoring function is specified ex ante, the forecaster can issue the optimal point forecast, namely, the ...
2009-01-01
A practical scheme for error control using feedback
We describe a scheme for quantum error correction that employs feedback and weak measurement rather than the standard tools of projective measurement and fast controlled unitary gates. The advantage of this scheme over previous protocols (for example Ahn et. al, PRA, 65, 042301 (2001)), is that it requires little side processing while remaining robust to measurement inefficiency, and is therefore considerably more practical. We evaluate the performance of our scheme by simulating the correction of bit-flips. We also consider implementation in a solid-state quantum computation architecture and estimate the maximal error rate which could be corrected with current technology.
2004-01-01
Practical statistics for particle physicists
Learning to love the errror matrix lecture : Learning to love the errror matrix Introductory remarks. Conditional probability. Statistical and systematic errors. Combining results Binomial, Poisson and 1-D Gaussian 2-D Gaussian and the error matrix. Understanding the covariance. Using the error matrix. Estimating the error matrix. Combining correlated measurements Parameter determination by likelihood Do's and don'ts lecture : Parameter determination by likelihood : Do's and don'ts Introduction to likelihood. Error estimate. Simple examples: (1) Breit Wigner (2) Lifetime Binned and unbinned likelihood Several parameters Extended maximum likelihood. Common misapprehensions: Normalisation delta(lnL) = 1/2 rule and coverage Integrating the likelihood Unbinned L_max as goodness of fit Punzi effect Chi-squared and hypothesis testing lecture : Chi-squared and ...
2006-01-01
TOA/FOA geolocation error analysis.
Energy Technology Data Exchange (ETDEWEB)
This paper describes how confidence intervals can be calculated for radiofrequency emitter position estimates based on time-of-arrival and frequency-of-arrival measurements taken at several satellites. These confidence intervals take the form of 50th and 95th percentile circles and ellipses to convey horizontal error and linear intervals to give vertical error. We consider both cases where an assumed altitude is and is not used. Analysis of velocity errors is also considered. We derive confidence intervals for horizontal velocity magnitude and direction including the case where the emitter velocity is assumed to be purely horizontal, i.e., parallel to the ellipsoid. Additionally, we derive an algorithm that we use to combine multiple position fixes to reduce location error. The algorithm uses all available data, after more than one location estimate for an emitter has been made, in ...
2008-08-01
Cause analysis and preventives for human error events in Daya Bay NPP
International Nuclear Information System (INIS)
Daya Bay Nuclear Power Plant is put into commercial operation in 1994 Until 1996, there are 368 human error events in operating and maintenance area, occupying 39% of total events. These events occurred mainly in the processes of maintenance, test equipment isolation and system on-line, in particular in refuelling and maintenance. The author analyses root causes for human errorievents, which are mainly operator omission or error procedure deficiency; procedure not followed; lack of training; communication failures; work management inadequacy. The protective measures and treatment principle for human error events are also discussed, and several examples applying them are given. Finally, it is put forward that key to prevent human error event lies in the coordination and management, person in charge of work, and good work habits of staffs.
Corrections for non-homogeneity of the sample in Moessbauer f-factor measurements
Energy Technology Data Exchange (ETDEWEB)
We describe a procedure for correcting the systematic errors in the Moessbauer f-factor measurement due to non-homogeneous effective thickness of the sample. To be more precise, we show that, if the mass of the sample is determined by means of X- or {gamma}-ray absorption, it is possible to establish experimental conditions so that the error on f due to material non-homogeneity in the sample is minimized.
2002-06-01
Energy Technology Data Exchange (ETDEWEB)
The bullet evidence in the JFK assassination investigation was reexamined from metallurgical and statistical standpoints. The questioned specimens are comprised of soft lead, possibly from full-metal-jacketed Mannlicher-Carcano, 6.5-mm ammunition. During lead refining, contaminant elements are removed to specified levels for a desired alloy or composition. Microsegregation of trace and minor elements during lead casting and processing can account for the experimental variabilities measured in various evidentiary and comparison samples by laboratory analysts. Thus, elevated concentrations of antimony and copper at crystallographic grain boundaries, the widely varying sizes of grains in Mannlicher-Carcano bullet lead, and the 5-60 mg bullet samples analyzed for assassination intelligence effectively resulted in operational sampling error for the analyses. This deficiency was not considered in the original data interpretation ...
2006-08-29
Performance testing of selected types of electronic personal dosimeters used in Sudan
International Nuclear Information System (INIS)
Measurements were carried out for calibration and performance testing of a set of 10 electronic personal dosimeters (EPDs) at the Secondary Standard Dosimetry Laboratory of Sudan. Calibrations were carried out at three X-ray beam qualities described in ISO standard 4037 in addition to 137Cs and 60Co gamma ray beams. The experimental was performed with EPDs mounted on ICRU Slab phantom. X-ray and ?-ray beams were characterized in terms of air kerma free-in-air which were converted to the known delivered personal dose equivalent, Hp(10) using appropriate the air kerma to personal dose equivalent conversion coefficients. Dosimeters tested showed excellent energy and angular response and relative error of indication within the recommended limit for photon energies from 65 keV to 1.25 MeV. The study showed encouraging results for using electronic dosimeters in personal dosimetry.
2010-12-01
Energy Technology Data Exchange (ETDEWEB)
This paper presents a nonlinear Bayesian regression algorithm for the purpose of detecting and estimating gas plume content from hyper-spectral data. Remote sensing data, by its very nature, is collected under less controlled conditions than laboratory data. As a result, the physics-based model that is used to describe the relationship between the observed remotesensing spectra, and the terrestrial (or atmospheric) parameters that we desire to estimate, is typically littered with many unknown "nuisance" parameters (parameters that we are not interested in estimating, but also appear in the model). Bayesian methods are well-suited for this context as they automatically incorporate the uncertainties associated with all nuisance parameters into the error estimates of the parameters of interest. The nonlinear Bayesian regression methodology is illustrated on realistic simulated data from a three-layer model for longwave infrared (LWIR) ...
2007-06-13
Statement of work for analytical services provided by PNNL`sanalytical chemistry laboratory
Energy Technology Data Exchange (ETDEWEB)
The purpose of this statement of work (SOW) is to establish laboratory analytical criteria and requirements for radioactive airborne emissions measurement sample and/or analysis activities.
1997-06-30
Measurement of magnetic fields in the Area Metropolitana
International Nuclear Information System (INIS)
The operation and proper handling of equipment for measuring EMR-300 electromagnetic waves are studied and apply that knowledge to determine which areas of the metropolitan area are mostly affected by exposure to the emission of radiation. This team is able to measure magnetic field strength, electric field strength and power density, also can measure the most important parameters in a simple manner. International standards provide maximum values for these parameters that limit human exposure to such radiation. These standards are based on epidemiological several and laboratory that have been carried out in order to determine in which circumstances a biological entity is exposed to a level of radiation that can cause harm to their health. It focuses on measuring the level of radiation in certain areas of interest, which were chosen because are areas with high population density and ...
Energy Technology Data Exchange (ETDEWEB)
Additional results using a calorimetric technique for measuring the total hemispherical emittance of pipe surfaces from 400 to 600 K are described. Two different Pyrex pipe enclosures were used, one of 15 cm i.d. and the other of 30 cm i.d. An error analysis showed that the larger diameter Pyrex pipe should have a smaller error, but the difference was negligible for the 4.4-cm test pipe diameter used. Measurements on a short length of a previously-measured pipe agreed with earlier measurements, but only over the temperature range of the measurements. While the technique normally uses a vacuum to minimize nonradiative heat transfer, measurements were done succesfully with an argon atmosphere in a closed system. A nickel-plated pipe, measured first in a vacuum and then in an argon atmosphere, allowed ...
1981-10-01
Measurement and analysis of neutron-induced soft errors in sub-half-micron CMOS circuits
Energy Technology Data Exchange (ETDEWEB)
Neutron-induced soft error rates (SER`s) of subhalf-micron CMOS SRAM and Latch circuits were studied both experimentally and analytically to investigate cosmic ray neutron-induced soft errors (SE`s). Because the neutron beam used in the measurement has an energy spectrum similar to that of sea-level atmospheric neutrons, the SER data corresponds to those induced by cosmic ray neutrons. The {alpha}-particle induced SER`s were also measured for comparison with the neutron-induced SER`s. Neutron-induced SE`s occurred in both circuits. On the other hand, {alpha}-induced SE`s occurred in SRAM, but not in the Latch circuit. The measured SER`s agreed with simulated results. The authors discussed the significance of how cosmic ray neutrons affects CMOS circuits at ground level.
1998-07-01
Tomography and Methods of Travel-Time Calculation for Regional Seismic Location
Energy Technology Data Exchange (ETDEWEB)
We are developing a laterally variable velocity model of the crust and upper mantle across Eurasia and North Africa to reduce event location error by improving regional travel-time prediction accuracy. The model includes both P and S velocities and we describe methods to compute travel-times for Pn, Sn, Pg, and Lg phases. For crustal phases Pg and Lg we assume that the waves travel laterally at mid-crustal depths, with added ray segments from the event and station to the mid crustal layer. Our work on Pn and Sn travel-times extends the methods described by Zhao and Xie (1993). With consideration for a continent scale model and application to seismic location, we extend the model parameterization of Zhao and Xie (1993) by allowing the upper-mantle velocity gradient to vary laterally. This extension is needed to accommodate the large variation in gradient that is known to exist across Eurasia and North African. Further, we extend the linear travel-time calculation ...
2007-07-02
A comprehensive understanding of the efficacy of N-Ring hardening methodologies in SiGe HBTs
International Nuclear Information System (INIS)
We investigate the efficacy of mitigating radiation-based single event effects (SEE) within circuits incorporating SiGe heterojunction bipolar transistors (HBTs) built with an N-Ring, a transistor-level layout-based radiation hardened by design (RHBD) technique. Previous work of single-device ion-beam induced charge collection (IBICC) studies has demonstrated significant reductions in peak collector charge collection and sensitive area for charge collection; however, few circuit studies using this technique have been performed. Transient studies performed with Sandia National Laboratory's (SNL) 36 MeV 16O microbeam on voltage references built with N-Ring SiGe HBTs have shown mixed results, with reductions in the number of large voltage disruptions in addition to new sensitive areas of low-level output voltage disturbances. Similar discrepancies between device-level IBICC results and circuit measurements are found for the case of digital shift ...
2010-07-19
The approximate maximum-likelihood certificate
A new property which relies on the linear programming (LP) decoder, the approximate maximum-likelihood certificate (AMLC), is introduced. When using the belief propagation decoder, this property is a measure of how close the decoded codeword is to the LP solution. Using upper bounding techniques, it is demonstrated that the conditional frame error probability given that the AMLC holds is, with some degree of confidence, below a threshold. In channels with low noise, this threshold is several orders of magnitude lower than the simulated frame error rate, and our bound holds with very high degree of confidence. In contrast, showing this error performance by simulation would require very long Monte Carlo runs. When the AMLC holds, our approach thus provides the decoder with extra error detection capability, which is especially important in applications requiring high data integrity.
2011-01-01
Development of a robotics system for automated chemical analysis of sediment, sludges, and soils
International Nuclear Information System (INIS)
The introduction of automation technology into the analytical laboratory holds the promise of higher efficiency, improved productivity, and lower costs. However, the conventional ''laboratory robot'' widely used today may not offer the work envelope or reliability required in a high workload laboratory performing quality control or environmental analytical services. To address this need, a demonstration workcell was assembled utilizing an industrial-class robotics system to automate a standard EPA acid digestion protocol. With further development of graphical user interfaces and error recovery software, the technology will significantly enhance the ability of laboratories to meet increasingly complex environmental demands. 7 refs., 2 figs., 1 tab.
1989-11-26
Measurement error modeling and nutritional epidemiology association analyses
British Library Electronic Table of Contents (United Kingdom)
Abstract This article summarizes the results of a Nutrient Biomarker Study in the Women's Health Initiative, and its application to studies of the association between energy and protein consumption and the risk of major cancers and cardiovascular diseases. The presentation emphasizes measurement error modeling and related data analysis methods, since addressing measurement issues appears to be central to these topics and to progress in nutritional epidemiology more generally. The manner in which body mass index is modeled in disease association analysis is particularly challenging, since it could serve as a mediator or as a confounder of the association, and at the same time contributes valuably to energy and protein consumption assessment. A hazard ratio parameter estimation procedure tha...
2011-01-01
International Nuclear Information System (INIS)
Formulae are derived for estimation of the effect of gamma beam divergence on the value of systematic and statistical components of the errors of density measurement in production of structural materials and products also in the process of exploitation of building structures and constructions. Engineering technique for choice of the distance between radiation source and object under test is developed for absorption radioisotope densimeter operating by the scheme of geometry of divergent beam with amplitude compensation of backscattered radiation effect. The assessment of radioisotope densimeter efficiency providing the error of density measurement prescribed at design stage
The fast rotating wire scanners installed in the PS and the PS booster are used for the precise transversal profile measurements in horizontal and vertical planes. The scanners may show large position measurement errors if no special treatment is applied to the acquired data. The aim of the calibration is to obtain a correction algorithm for the systematic position measurement error due to mechanical and electronic offsets. A new calibration system has been developed and introduced at CERN for the scanners implementing position feedback control. The calibration method is based on a substitution of a particle beam by a laser one where the laser beam position is well known. According to the previous experience the following crucial requirements to the system have been taking into consideration: heavy and mechanically stable design of the calibration bench to reduce mechanical ...
2009-01-01
Hydrogen storage in nano-structured carbon materials
Energy Technology Data Exchange (ETDEWEB)
Full text of publication follows: Energy and environment are two major concerns in our modern society due to the coming shortage in fossil energy sources and the growing of greenhouse gas emissions. The challenge for the coming years is to discover new energy resources and to develop devices that are compatible with a sustainable development and generate few (or zero) emission. One of these devices is the fuel cell feed by hydrogen, whose application fields are very large. In particular, the proton exchange membrane fuel cell (PEMFC) is the most realistic device for automotive application. However, hydrogen storage remains one of the most important challenges regarding its development. Although different techniques are available for storing hydrogen, no ideal solution has been found yet. Compression needs elaborated tanks in shape for supporting high pressures, liquefaction requires an expensive hydrogen cooling and adapted tanks. Chemical storage by hydrides imposes heavy devices. A ...
2005-07-01
Hydrogen storage in nano-structured carbon materials
Energy Technology Data Exchange (ETDEWEB)
Full text of publication follows: Energy and environment are two major concerns in our modern society due to the coming shortage in fossil energy sources and the growing of greenhouse gas emissions. The challenge for the coming years is to discover new energy resources and to develop devices that are compatible with a sustainable development and generate few (or zero) emission. One of these devices is the fuel cell feed by hydrogen, whose application fields are very large. In particular, the proton exchange membrane fuel cell (PEMFC) is the most realistic device for automotive application. However, hydrogen storage remains one of the most important challenges regarding its development. Although different techniques are available for storing hydrogen, no ideal solution has been found yet. Compression needs elaborated tanks in shape for supporting high pressures, liquefaction requires an expensive hydrogen cooling and adapted tanks. Chemical storage by hydrides imposes heavy devices. A ...
2005-07-01
Measurement of the oil consumption of compressors
International Nuclear Information System (INIS)
This paper describes a method for measuring oil consumption in compressors. The oil is labelled with Zn 65. The consumed radioactive oil is retained in an activated carbon filter and its activity is measured continuously with a plastic scintillator detector. Measuring the oil consumption at a given operating levels takes about 15 minutes. At an oil consumption rate of about 1 g/h the measurement errors are of the order of +- 5%. (orig.).
Energy Technology Data Exchange (ETDEWEB)
The existing theoretical and experimental basis for predicting the levels of resonant static error field at different components m,n that stop plasma rotation and produce a locked mode is reviewed. For ITER ohmic discharges, the slow rotation of the very large plasma is predicted to incur a locked mode (and subsequent disastrous large magnetic islands) at a simultaneous weighted error field ({Sigma}{sub 1}{sup 3}w{sub m1}B{sup 2}{sub rm1}){sup {1/2}}/B{sub T} {ge} 1.9 x 10{sup -5}. Here the weights w{sub m1} are empirically determined from measurements on DIII-D to be w{sub 11} = 0. 2, w{sub 21} = 1.0, and w{sub 31} = 0. 8 and point out the relative importance of different error field components. This could be greatly obviated by application of counter injected neutral beams (which adds fluid flow to the natural ohmic electron drift). The addition of 5 MW of 1 MeV beams at 45{degrees} injection would ...
1997-02-01
UK PubMed Central (United Kingdom)
BackgroundKinematic and kinetic measurements used in laboratory settings can quantify upper extremity movement impairment following stroke, but their relationship...Full Text Available
2008-01-01
Electromagnetic wiggler technology development at the Lawrence Livermore National Laboratory
Energy Technology Data Exchange (ETDEWEB)
As a part of the program at the Lawrence Livermore National Laboratory (LLNL) in induction-linac free-electron laser (IFEL) research, the authors are conducting a variety of activities addressing the unique requirements imposed on IFEL wiggler systems. They are actively developing improved DC iron-core electromagnetic wiggler designs to attain higher peak fields, greater tunability, and lower random error levels. They are pursuing specialized control systems, such as magnetic-field and beam-position controllers, which can relax requirements on the wiggler itself. They are also pursuing basic studies to establish the effect of radiation on permanent magnets.
1988-03-01
Electromagnetic wiggler technology development at the Lawrence Livermore National Laboratory
Energy Technology Data Exchange (ETDEWEB)
As a part of the program at the Lawrence Livermore National Laboratory (LLNL) in induction-linac free-electron laser (IFEL) research, we are conducting a variety of activities addressing the unique requirements imposed on IFEL wiggler systems. We are actively developing improved dc iron-core electromagnetic wiggler designs to attain higher peak fields, greater tunability, and lower random error levels. We are pursuing specialized control systems, such as magnetic-field and beam-position controllers, which can relax requirements on the wiggler itself. We are also pursuing basic studies to establish the effect of radiation on permanent magnets.
1987-01-01
Energy Technology Data Exchange (ETDEWEB)
In order to consider some procedures to prevent errors in radiotherapy based in learned lessons of accidental expositions and in accordance with information contained in international reports elaborated by International Atomic Energy Agency (IAEA) and of the data base availability by the European group Radiation Oncology Safety Information System (ROSIS) on the events, a research of the occurred errors was performed. For the evaluation of the incidents a data base based in the ROSIS and added plus a parameter was created 'type of error'. All the stored data make possible the evaluation of the 839 incidents in terms of frequency of the type of error, the process of detention, the number of reached patients and the degree of severity. Of the 50 types of found errors, the type of error more frequently was 'incorrect treatment ...
2007-07-01
Reevaluation of 58Ni and 60Ni Resonance Parameters in the Energy Range Thermal to 800 keV
Energy Technology Data Exchange (ETDEWEB)
The previous 58Ni and 60Ni set of resonance parameters (ENDF/B-VII-0, JEFF-3, etc.) was based on the SAMMY analysis of Oak Ridge National Laboratory neutron transmission, scattering cross section and capture cross section measurements by C. M. Perey et al. The present results were obtained by adding to the SAMMY experimental data base the capture cross sections measured recently at the Oak Ridge Linear Electron Accelerator by Guber et al. and the Geel Electron Linear Accelerator very high-resolution neutron transmission measurements performed by Brusegan et al. A complete resonance parameter covariance matrix (RPCM) was obtained from the SAMMY analysis of the experimental database. The data sets were made consistent, when needed, by adjusting the neutron energy scales, the normalization coefficients, and the background corrections. The RPCM allows the calculation of the cross section uncertainties due ...
2009-09-01
Energy Technology Data Exchange (ETDEWEB)
The previous {sup 58}Ni and {sup 60}Ni set of resonance parameters (Endf/B7.O, Jeff-3, etc.) was based on the SAMMY analysis of Oak Ridge National Laboratory neutron transmission, scattering cross section and capture cross section measurements by C.M. Perey et al. The present results were obtained by adding to the SAMMY experimental database the capture cross sections measured recently at the Oak Ridge Linear Electron Accelerator by Guber et al. and the Geel Electron Linear Accelerator and very high-resolution neutron transmission measurements performed by Brusegan et al. A complete resonance parameter covariance matrix (RPCM) was obtained from the SAMMY analysis of the experimental database. The data sets were made consistent, when needed, by adjusting the neutron energy scales, the normalization coefficients, and the background corrections. The RPCM allows the calculation of the cross section ...
2009-07-01
Modified accumulator method for measuring surface radon flux from a uranium tailings pile
Energy Technology Data Exchange (ETDEWEB)
A modified accumulator was devised to measure surface radon flux from porous media. It consists of a collector hood accumulator with a homogenizer pump and a pressure balancer. The latter was used to compensate for any pressure changes produced during sample withdrawl and hence eliminate additional radon transport from media. Errors resulting from radon back diffusion due to decreasing concentration gradient with time across the interface were eliminated by measuring radon concentrations in the accumulator for two different periods of time and calculating the true radon flux, J(o), from the solution of a time-dependent radon transport equation. Core samples from the observation site were withdrawn for laboratory determination of porosity, moisture content, bulk and grain densities, Ra-226 source concentration and the fraction of Rn-222 produced in the void volume. The data were used to calculate the ...
1982-07-01
A modified accumulator method for measuring surface radon flux from a uranium tailings pile
International Nuclear Information System (INIS)
A modified accumulator was devised to measure surface radon flux from porous media. It consists of a collector hood accumulator with a homogenizer pump and a pressure balancer. The latter was used to compensate for any pressure changes produced during sample withdrawl and hence eliminate additional radon transport from media. Errors resulting from radon back diffusion due to decreasing concentration gradient with time across the interface were eliminated by measuring radon concentrations in the accumulator for two different periods of time and calculating the true radon flux, J(o), from the solution of a time-dependent radon transport equation. Core samples from the observation site were withdrawn for laboratory determination of pkrosity, moisture content, bulk and grain densities, Ra-226 source concentration and the fraction of Rn-222 produced in the void volume. The data were used to calculate the ...
Total hemispherical emittance measured at high temperatures by the calorimetric method
Energy Technology Data Exchange (ETDEWEB)
A calorimetric vacuum emissometer (CVE) capable of measuring total hemispherical emittance of surfaces at elevated temperatures was designed, built, and tested. Several materials with a wide range of emittances were measured in the CVE between 773 to 923 K. These results were compared to values calculated from spectral emittance curves measured in a room temperature Hohlraum reflectometer and in an open-air elevated temperature emissometer. The results differed by as much as 0.2 for some materials but were in closer agreement for the more highly-emitting, diffuse-reflecting samples. The differences were attributed to temperature, atmospheric, and directional effects, and errors in the Hohlraum and emissometer measurements ({+-} 5 percent). The probable error of the CVE measurements was typically less than 1 percent.
1994-09-01
Choice of energies in gamma-absorption method for layers thickness measuring of two-layers articles
International Nuclear Information System (INIS)
Empirical formulae are proposed for the description of relation between optimum energies minimizing the mean-weighted error of gamma absorption measurement of the thickness of layers in two-layer products with the thickness of every layer from 30 up to 150 mm by carbon. Error of informational parameter approximation with the application of tables does not exceed 10% in case of non-accurate assessment of layers thickness not exceeding 2.5%. Generalized equation is derived which binds main parameters of the task and permits to choose optimum energies with the accuracy sufficient for practical purposes
A simple system of instruments for radionuclide X-ray fluorescence analysis in nonferrous metallurgy
International Nuclear Information System (INIS)
Proceeding from commercially available instruments, a simple measuring system has been established, which renders possible fast and simple discontinuous analysis of individual elements. This measuring system is described, giving some examples of utilization in nonferrous metallurgy (mining, ore dressing, metallurgical treatment), and specific details, such as error of measurement, ranges of measurement and limits of utilization. (author).
1979-01-01
Quality assurance handbook for measurement laboratories
International Nuclear Information System (INIS)
This handbook provides guidance in the application of quality assurance to measurement activities. It is intended to help those persons making measurements in applying quality assurance to their work activities by showing how laboratory practices and quality assurance requirements are integrated to provide control within those activities. The use of the guidance found in this handbook should help provide consistency in the interpretation of quality assurance requirements across all types of measurement laboratories. This handbook also can assist quality assurance personnel in understanding the relationships between laboratory practices and quality assurance requirements. The handbook is composed of three chapters and several appendices. Basic guidance is provided by the three chapters. In Chapter 1, the role of quality assurance in obtaining quality data and the ...
Ground- and space-based temperature and humidity retrievals: Statistical evaluation
Energy Technology Data Exchange (ETDEWEB)
A near-real-time integrated temperature and water vapor sounding system has been designed and in operation since June 1993. It combines hourly data from the ground-based radio acoustic sounding system (RASS), a two-channel microwave radiometer, standard surface meteorological instruments, a lidar ceilometer, and the Aerodynamic Research Incorporated Communication, Addressing and Reporting System aboard commercial airlines with space-based data from the TIROS-N Operational Vertical Sounder (TOVS). The physical retrieval algorithm provided by the International TOVS Processing Package is used for combining the ground- and space-based temperature and humidity profiles. The first-guess profiles of temperature and humidity required by the physical retrieval algorithm are obtained by using a statistical inversion technique and the ground-based remote sensors measurements. Statistical error estimates are presented for the hourly, near-real-time, ...
1996-03-01
Authentication of byte sequences
Energy Technology Data Exchange (ETDEWEB)
Algorithms for the authentication of byte sequences are described. The algorithms are designed to authenticate data in the Storage, Retrieval, Analysis, and Display (SRAD) Test Data Archive of the Radiation Effects and Testing Directorate (9100) at Sandia National Laboratories, and may be used in similar situations where authentication of stored data is required. The algorithms use a well-known error detection method called the Cyclic Redundancy Check (CRC). When a byte sequence is authenticated and stored, CRC bytes are generated and attached to the end of the sequence. When the authenticated data is retrieved, the authentication check consists of processing the entire sequence, including the CRC bytes, and checking for a remainder of zero. The error detection properties of the CRC are extensive and result in a reliable authentication of SRAD data.
1991-06-01
Quantifying costs of forecast errors: A case study of the warehouse environment
British Library Electronic Table of Contents (United Kingdom)
Our study evaluates the impact of forecast errors on organizational cost by simulating a labor-intensive warehouse environment using realistic cost data from a case study. Unlike past studies that measure forecast error in terms of forecast standard deviation, our study also considers the impact of forecast bias, and the complex interaction between these variables. Two cases of organizational cost curves are considered, with differing and asymmetric structures. Results find forecast bias to have a considerably greater impact on organizational cost than forecast standard deviation. Particularly damaging is a high bias in the presence of high forecast standard deviation. Although biasing the forecast in the least costly direction is shown to yield lower costs, sensitivity analysis shows that...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
Traditional laboratory diffusion experiments in rock material are time consuming, and quite small samples are generally used. Electrical conductivity measurements, on the other hand, provide a fast means for examining transport properties in rock and allow measurements on larger samples as well. Laboratory measurements using electrical conductivity give results that compare well to those from traditional diffusion experiments. The measurement of the electrical resistivity in the rock surrounding a borehole is a standard method for the detection of water conducting fractures. If these data could be correlated to matrix diffusion properties, in-situ diffusion data from large areas could be obtained. This would be valuable because it would make it possible to obtain data very early in future investigations of potentially suitable sites for a repository. This study ...
1998-09-01
Thermal radiation from hot surfaces measured by optical and calorimetric methods. Master's thesis
Energy Technology Data Exchange (ETDEWEB)
The radiative heat loss from a surface is determined by its total hemispherical emittance, which consequently plays an important role in aerospace and solar applications. This study compares emittances measured calorimetrically with values derived from near normal incidence spectral reflectance measurements. This optical derivation is based on a number of assumptions which limit the accuracy if not sufficiency fulfilled. These assumptions include sample specularity, a straybody character beyond the range of measurement, only small variations of emittance with temperature, and a perfectly smooth sample surface. The comparison of calorimetrically and optically derived emittance performed in this study not only quantifies the errors introduced by insufficient fulfillment of the assumptions but also identifies which assumption causes the dominant error. The calorimetric emissometer, ...
1982-01-01
On the accuracy and effectiveness of dose reconstruction for tomotherapy
International Nuclear Information System (INIS)
Dose reconstruction is a process that re-creates the treatment-time dose deposited in a patient provided there is knowledge of the delivered energy fluence and the patient's anatomy at the time of treatment. A method for reconstructing dose is presented. The process starts with delivery verification, in which the incident energy fluence from a treatment is computed using the exit detector signal and a transfer matrix to convert the detector signal to energy fluence. With the verified energy fluence and a CT image of the patient in the treatment position, the treatment-time dose distribution is computed using any model-based algorithm such as convolution/superposition or Monte Carlo. The accuracy of dose reconstruction and the ability of the process to reveal delivery errors are presented. Regarding accuracy, a reconstructed dose distribution was compared with a measured film distribution for a simulated breast treatment carried out on a thorax ...
2001-04-01
Alignment accuracy of focused ion beam implantation
Energy Technology Data Exchange (ETDEWEB)
The theoretical alignment limit for focused ion beam (FIB) implantation was deduced from the calculated resolution for the detection of an alignment mark. The alignment resolution varies with the signal to noise ratio and there is an optimum current which gives the best resolution. The alignment resolution epsilon/sub sigma/ is approximately 0.006 ..mu..m for a 160 keV Si/sup ++/ beam from our FIB implanter. The measured alignment error is approximately 0.06 ..mu..m and the main reason of this discrepancy is vibration. The ultimate limit on the alignment error can be reached through improvements in the implanter system.
1987-06-01
International Nuclear Information System (INIS)
Inelastic scattering of #alpha#-particles in 22-24 MeV energy range on "1"8o o, "1"9f, "2"0Ne, "2"2Ne nuclei is investigated. Measurements of excitation functions were conducted for the beam of Leningrad University cyclo otron at several angles in 15-165 deg range of laboratory system with 2.5 deg spacing. The error of determining absolute cross sections equals +-20% for "2"2Ne and +-12% for other nuclei. Angular distributions have the differaction character, are similar in form for all nuclei, the values of differential cross- -sections don't exceed the rutherford values. The dependence of integral cross-sections on the energy of level excitation is similar to the exponential d dependence of cross-sections of production of the given element isotopes on the gergy difference of masses of final nuclear products in the reactions of deeply inelastic transfers with heavy ions. The observed isotopic effect in the value of ...
1983-04-01
The study of technical error analysis on BMD using DEXA
International Nuclear Information System (INIS)
This study was conducted to search for the type of technical error in DEXA (dual-energy X-ray absorptiometry) and the effect of error to measurement of BMD. The changes of BMD (g/cm2, T-score) by patients information (Age, Weight, Height, Manopause age) input error and Confirming ROI error were investigated. Using spine phantom, we canned 10 times by age (5, 10), weight (10, 20 kg), height (5, 10 cm), manopause age (5, 10) increase and decrease respectively. Scanning region (L-spine, femur, Forearm) of 10 patients was calculated by changing ROI respectively. Analysis of difference for mean (precision 1%) were carried out. There error of patient information (Age, Weight, Height, Manopause age) was not changed differently. In confirming ROI, the BMD and T-score of L-spine involving T-12 was decreased to 0.063 g/cm2, 0.3 and involving L-5 increased to 0.077 g/cm2, ...
2006-12-01
Environmental Measurements Laboratory fiscal year 1998: Accomplishments and technical activities
Energy Technology Data Exchange (ETDEWEB)
The Environmental Measurements Laboratory (EML) is government-owned, government-operated, and programmatically under the DOE Office of Environmental Management. The Laboratory is administered by the Chicago Operations Office. EML provides program management, technical assistance and data quality assurance for measurements of radiation and radioactivity relating to environmental restoration, global nuclear nonproliferation, and other priority issues for the Department of Energy, as well as for other government, national, and international organizations. This report presents the technical activities and accomplishments of EML for Fiscal Year 1998.
1999-01-01
Improved measurement of $\\psi (2S)$ decays into $\\tau ^{+}\\tau ^{-}$
Using 14M $\\psi (2S)$ events collected at BESII, the branching fraction of $\\psi (2S)\\to \\tau ^{+}\\tau ^{-}$ is measured to be $Br_{\\tau \\tau}=(3.10\\pm 0.21\\pm 0.38)\\times 10^{-3}$, where the first error is statistical and the second is systematic.
2006-01-01
Gamma absorption determination of concentration in a three-component mixture
International Nuclear Information System (INIS)
A method for the analysis of three-component mixtures is described. The method is used for contact-free determination of component concentration in the mixtures transported via a product duct. Formulae as an aid in choosing the gamma radiation source and estimating the efficiency of measurement are given. The errors of measurement by the method of formaline-water-carbamide mixture is 1-2 %. 9 refs.; 1 fig.
Estimation of errors provided with dead times of roentgen digital tomography
International Nuclear Information System (INIS)
Impact of apparatus dead time on the accuracy of measurement of radial distribution of the radiation attenuation factor in the roentgen computer tomography for rotation bodies is studied. Analytical expressions are obtained. Calculations of the threshold loads for radiometric detectors, providing for the accuracy of measurement at the stage of designing the tomographic complex detecting unit, are obtained
Uncertainties of radionuclide migration parameter values obtained from in-situ tracer experiments
International Nuclear Information System (INIS)
One of the key issues in safety assessment of high-level nuclear waste disposal is evaluating the effects of uncertainty inherent in radionuclide migration parameter values. In this paper, radionuclide transport parameter values and error variances (uncertainties) from in-situ tracer experiments, carried out in a single fracture at the Aespoe Hard Rock Laboratory (HRL) in Sweden, are identified by solving the inverse problem in a framework of the maximum likelihood theory. From the results, it is found that the parameter value uncertainty caused by a conceptual model of radionuclide migration is greater than that caused by a fluctuation in the observed breakthrough curve data. (author)
2005-10-03
Integrated design environment for human performance and human reliability analysis
Energy Technology Data Exchange (ETDEWEB)
Work over the last few years at the Idaho National Engineering and Environmental Laboratory (INEEL) has included a major focus on applying human performance and human reliability knowledge and methods as an integral element of system design and development. This work has been pursued in programs in a wide variety of technical domains, beginning with nuclear power plant operations. Since the mid-1980`s the laboratory has transferred the methods and tools developed in the nuclear domain to military weapons systems and aircraft, offshore oil and shipping operations, and commercial aviation operations and aircraft design. Through these diverse applications the laboratory has developed an integrated approach and framework for application of human performance analysis, human reliability analysis (HRA), operational data analysis, and simulation studies of human performance to the design and development of complex systems. This ...
1997-05-01
Measurement of low-energy antiproton detection efficiency in BESS below 1 GeV
Energy Technology Data Exchange (ETDEWEB)
An accelerator experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of BESS, a balloon-borne spectrometer with a superconducting solenoid. Measured efficiencies showed good agreement with calculated ones derived from the BESS Monte Carlo simulation based on GEANT/GHEISHA. With detailed verification of the BESS simulation, the relative systematic error of detection efficiency derived from the BESS simulation has been determined to be {+-}5%, compared with the previous estimation of {+-}15% which was the dominant uncertainty for measurements of cosmic-ray antiproton flux.
2002-08-21
Precision Measurements of the Cluster Red Sequence using an Error Corrected Gaussian Mixture Model
Energy Technology Data Exchange (ETDEWEB)
The red sequence is an important feature of galaxy clusters and plays a crucial role in optical cluster detection. Measurement of the slope and scatter of the red sequence are affected both by selection of red sequence galaxies and measurement errors. In this paper, we describe a new error corrected Gaussian Mixture Model for red sequence galaxy identification. Using this technique, we can remove the effects of measurement error and extract unbiased information about the intrinsic properties of the red sequence. We use this method to select red sequence galaxies in each of the 13,823 clusters in the maxBCG catalog, and measure the red sequence ridgeline location and scatter of each. These measurements provide precise constraints on the variation of the average red galaxy populations in the observed frame with redshift. ...
2009-07-01
Development of calibration facility for radiation protection monitoring instruments
International Nuclear Information System (INIS)
Exposure control at the operating Nuclear Power Station is a major concern. The challenging task of meeting the International standards in the field of radiation protection is the calibration of the radiation monitoring instruments and interpretation of personnel and area monitoring results. Correct interpretation is based on accurate calibration of radiation measuring instruments. The reliability and accuracy of the measurements are also partly based on the procedures applied in calibration. Inadequate calibration can cause large errors in dose estimation in complete dose rate range and energy range. Semiautomatic calibration facility established at TAPS 3 and 4 for radiation monitoring instruments. Objective of calibration facility is (a) Ensure instruments are working properly (b) calibration adjustment and (c) in case without calibration adjustment to reveal the error involved. The calibration ...
2008-11-19
Control of linear accelerator noise in the Los Alamos free-electron laser (FEL)
International Nuclear Information System (INIS)
FELs require tight control of the amplitudes and phase of the fields in two linear accelerator tanks to obtain stable lasing. The accelerator control loops must establish constant, stable, repeatable amplitudes and phases of the rf fields and must have excellent bandwidth to control high-frequency noise components. A model of the feedback loops has been developed that agrees well with measurements and allows easy substitution of components and circuits, thus reducing breadboarding requirements. The model permits both frequency and time-domain analysis. The accelerator control scheme and model are described and the control of noise in feedback loops is discussed, showing how low-frequency-noise components (errors) can be corrected, but high-frequency-noise components (errors) are actually amplified by the feedback circuit. Measurements of noise in both open- and closed-loop modes is shown and comparison ...
1986-09-01
Energy Technology Data Exchange (ETDEWEB)
This paper reports on a series of laboratory and controlled test site measurements of the thermal conductivity of polyisocyanurate foam laminated boardstock roof insulations produced with several different blowing agents; CFC-11, HCFC-123, HCFC-14lb, and two blends of the HCFCs. The behavior of the experimental foams with HCFCs is compared to that of conventional polyisocyanurate foam blown with CFC-11. Thermal drift observed from two years of field exposure is compared to laboratory accelerated aging tests and the laboratory and field measurement techniques are described. This work is part of a Joint Industry/Government Project established in the United States to evaluate the technical viability of HCFC alternative blowing agents for polyisocyanurate foam roof insulations.
1992-01-01
A mobile remote sensing laboratory for water vapor, trace gas, aerosol, and wind speed measurements
Energy Technology Data Exchange (ETDEWEB)
The Lawrence Livermore National Laboratory has developed a mobile field laboratory for remote measurement of atmospheric processes and observables that are important in global climate change, dispersal of hazardous materials, and atmospheric pollution. Specific observables of interest are water vapor, trace gases, aerosol size and density, wind, and temperature. The goal is to study atmospheric processes continuously for extended periods in remote field locations. This laboratory has just reached field ready status with sensors for aerosol and trace gas measurement based on established techniques. A development program is underway to enhance the sensor suite with several new techniques and instruments that are expected to significantly extend the state of the art in remote trace gas analysis. The new sensors will be incorporated into the lab during the next two years.
1993-03-19
Radiometric measurement of temperature distributions in solar cavity receivers
Energy Technology Data Exchange (ETDEWEB)
An engineering tool incorporating a scanning infrared radiometer, an image digitizer, a microcomputer, and the software to drive the system was developed to allow remote mapping of the temperature distribution in solar cavity receivers. Using enclosure analysis, the infrared image processing program extracts the irradiance map from the radiosity map of the cavity to yield an emissive power map. Using the calibration curve of the radiometer and the emissivity of the surface of the cavity, the emissive power map is transformed into a temperature map. The system was tested by comparing its calculated temperatures to temperatures measured by thermocouples at several locations on the surfaces of heated model cavity receivers. The average relative error for the cavities ranged from 4.6%--34.9%, with the relative error on the base usually less than half that on the wall. Some work was also carried out to compensate the detected ...
1989-03-01
UK PubMed Central (United Kingdom)
BackgroundProspective measures of high knee abduction moment during landing identify female athletes at high risk for non-contact anterior cruciate ligament injury....Full Text Available
2010-08-01
Continuous measurement of blast-furnace coke moisture
International Nuclear Information System (INIS)
After presenting the advantages of applying neutron moisture gages to the continuous measurement of blast-furnace coke moisture and explaining the factors influencing the measurement accuracy, the necessity of calibrating these devices under flow conditions and the encountered difficulties are discussed. Using statistical methods it has been observed that the main source of calibration errors is the sampling phase. Based on results of mathematical processing, a new calibration method with higher performance - compared with the earlier ones - is proposed. This method allows to achieve high accuracy in a relatively short time. (author).
Absolute calibration of the antiproton detection efficiency for BESS below 1 GeV
Energy Technology Data Exchange (ETDEWEB)
An accelerator beam experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of the BESS detector. Measured and calculated efficiencies derived from the BESS Monte Carlo simulation based on GRANT/GHEISHA showed good agreement. With detailed verification of the BESS simulation, the relative systematic error of detection efficiency derived from the BESS simulation has been determined to be {+-}5%, compared with the previous estimation of {+-}15% which was the dominant uncertainty for measurements of cosmic-ray antiproton flux. (author)
2001-12-01
Intercomparison of soil radon concentration measurements
International Nuclear Information System (INIS)
In October last year the first intercomparison of measurements of the soil radon concentrations between various laboratories in Slovakia was realised. The organisation of this intercomparison was conducted by the Slovak Legal Metrology in Banska Bystrica together with the Slovak National Accreditation Service in Bratislava (SNAS). The scientific guarantee of the exercise was the State metrological Centre for radon quantities, which is working at the Research base of Slovak Medical University in Bratislava. The main objective of the intercomparison was to verify the correctness of the methods for the soil radon measurements of the authorised laboratories for radon volume activities in soil air. The intercomparison (signed as SLM ILC 3/03) was performed as a 'circular' metrology comparison, in accordance with a methodical directive MSA 0117-98, published by SNAS. Six laboratories were ...
2004-11-01
Demonstration experiments of volume measurement technique for large scale input accountancy tank
International Nuclear Information System (INIS)
Tank calibration experiments have been carried out using a mock-up input accountancy tank with the object of developing a high accuracy solution volume measurement technique for Rokkasho Reprocessing Plant (RRP). The experimental parameters such as temperature, solution density, off gas pressure and so on have been fluctuated in the calibration experiments in order to evaluate the influence on the solution volume measurement. As a result, it was confirmed that the solution volume measurement error of the mock-up tank was within #+-#0.04% (at full volume) using careful data correction technique for measured data. For the high accuracy volume measurement at RRP, it is important to correct data properly taking account of the actual conditions such as uncontrollable ambient temperature that are different from the experiment. (author)
2000-12-07
Radiogauging to investigate two phase flow. Graduation report
Energy Technology Data Exchange (ETDEWEB)
New measuring methods are developed and are tested with the small reactor simulator MIDAS (Mini Dodewaard ASsembly). The purpose of this work is to be able to measure accurately as many different properties of the flow as possible in the coming bigger simulator SIDAS (Simulated Dodewaard ASsembly). In SIDAS the flow around a fuel assembly of the Dutch Dodewaard reactor will be simulated. An extensive evaluation of the gamma detection system showed that the detection system could be simplified strongly. The simplified system is used to measure the radial and axial distribution of the void fraction in the core of MIDAS for three different operating conditions. Two new measuring methods have been developed and tested. A method to estimate the probability density of the void fraction in time. Due to the nonlinear relation between transmission and void fraction the determined average value of the void ...
1992-11-12
The safety concept of public gas supply in Germany
Energy Technology Data Exchange (ETDEWEB)
The risk perception of the public consists of two components: the objectively factual component and the subjectively irrational component. The two strategies adopted by the German gas supply industry are the internal and the external communication strategy. Concepts and measures of accident precaution, registration and analysis of accident data (installation and operating errors, defects on flue systems, pipelines and valves, subsequent installation of gas appliances) are discussed. (R.P.)
1997-09-01
On stochastic approximation algorithms for classes of PAC learning problems
Energy Technology Data Exchange (ETDEWEB)
The classical stochastic approximation methods are shown to yield algorithms to solve several formulations of the PAC learning problem defined on the domain [o,1]{sup d}. Under some assumptions on different ability of the probability measure functions, simple algorithms to solve some PAC learning problems are proposed based on networks of non-polynomial units (e.g. artificial neural networks). Conditions on the sizes of these samples required to ensure the error bounds are derived using martingale inequalities.
1994-03-01
Magnetic diagnostic of beta poloidal and internal inductance of plasma in the TCA/BR tokamak
Energy Technology Data Exchange (ETDEWEB)
This report continues the studies of simplified methods, of magnetic diagnostics in application to TCA/BR tokamak. Here we study the accuracy of known formula for {beta}{sub 1} + l{sub 1}/2 determination from the poloidal magnetic field asymmetry. Errors of the diamagnetic measurements due to vibrations of the vacuum vessel are also considered. (author). 3 refs., 1 fig., 1 tab.
1996-12-31
Finding the best quadratic approximation of a function
British Library Electronic Table of Contents (United Kingdom)
This article examines the question of finding the best quadratic function to approximate a given function on an interval. The prototypical function considered is f(x) = ex. Two approaches are considered, one based on Taylor polynomial approximations at various points in the interval under consideration, the other based on the fact that three non-collinear points determine a unique quadratic function. Three different techniques for measuring the error in the approximations are considered.
2011-01-01
Outpatient Prescribing Errors and the Impact of Computerized Prescribing
UK PubMed Central (United Kingdom)
BackgroundMedication errors are common among inpatients and many are preventable with computerized prescribing. Relatively little is known about outpatient prescribing errors or...Full Text Available
2005-09-01
Optimization techniques for parameter estimations: case studies in CO{sub 2} separation processes
Energy Technology Data Exchange (ETDEWEB)
Application of an optimization technique to extract the non-ideal parameters of gas absorption with chemical reactions process was described. The gas absorption was modeled using mass transfer theory to represent the realistic behaviors of an absorber. The model was a highly non-linear iterative model which correlated the overall rate of absorption as the function of unknown non-ideal parameters, including the physical liquid mass transfer coefficient and the wetted interfacial area of of packings. The optimization program was developed to minimize the sum of squares of relative errors between the model predictions and the experimental data. Four sets of experimental data (case studies) with different operating conditions were used for extracting parameters. Comparisons between predicted and experimental measured overall absorption rate were in good agreement, average absolute value of relative errors not exceeding 5.4 %. ...
1995-12-31
Kolmogoroff constants at the 1976 ITCE
Energy Technology Data Exchange (ETDEWEB)
The high-frequency data from 12 sensors at the ITCE 1976 are analyzed to determine the Kolmogoroff constants for velocity, temperature and humidity fluctuations, ..cap alpha../sub u/, ..cap alpha../sub T/, and ..cap alpha../sub q/. The occurrence of aliasing in the spectral analysis in some cases together with the limited response of some sensors at the higher frequencies introduces some uncertainties into the analysis. The Soviet sonic anemometer, fine-wire thermometer and infrared hygrometer and the Australian infrared hygrometer provide the best information, namely that: ..cap alpha../sub u/ = 0.59 +/- 0.01, ..cap alpha../sub T/ = 0.68 +/- 0.02, ..cap alpha../sub q/ = 0.76 +/- 0.03, where the errors quoted refer solely to statistical errors. The other instruments provide general support to these values. The technique of using spectral density measurements to determine eddy fluxes is illustrated.
1982-01-01
Establishment of a method for RIA of transferrin
International Nuclear Information System (INIS)
Objective: To develop a method for RIA of transferrin without dilution of the serum sample. Methods: The measurable range was broadened through: Lowering of the specific radioactivity of the labelled antigen, increasing the concentration of the anti-serum and improve the curve fitting method. Results: The antiserum affinity was 3.82 x 10"-"1"0 mol/L, the specific radioactivity of the labelled antigen was 15.3 mg/mic, inter-assay error CV 5.38%, intra-assay error CV = 3.5% and the shape of the curve was good. For 30 normal control specimens, the mean TF content was 2.81 +- 0.972 mg/ml. Conclusion: Development of a method for RIA of TF without previous dilution of the test serum was of clinical value
2002-04-01
Design concept for radiation hardening of low power and low voltage dynamic memories
International Nuclear Information System (INIS)
A radiation hard low power, low voltage dynamic memory is obtained by the use of a dummy cell concept. Compared to conventional dummy cell concepts, this concept applies a fully sized dummy cell. By optimizing the dummy cell precharge voltage for 5 V and 3 V operation and the timing of the dummy word-line, the overall soft error rate (SER) of the chip is improved by 2 orders of magnitude. An additional improvement of 1 order of magnitude is possible for 3 V operation by adjusting substrate bias and cell plate voltage. The results are verified by an accelerated SER measurement with a radium 226 source and an additional field soft error study.
On the application of Allan variance method for Ring Laser Gyro performance characterization
Energy Technology Data Exchange (ETDEWEB)
This report describes the method of Allan variance and its application to the characterization of a Ring Laser Gyro`s (RLG) performance. Allan variance, a time domain analysis technique, is an accepted IEEE standard for gyro specifications. The method was initially developed by David Allan of the National Bureau of Standards to quantify the error statistics of a Cesium beam frequency standard employed as the US Frequency Standards in 1960`s. The method can, in general, be applied to analyze the error characteristics of any precision measurement instrument. The key attribute of the method is that it allows for a finer, easier characterization and identification of error sources and their contribution to the overall noise statistics. This report presents an overview of the method, explains the relationship between Allan variance and power spectral density distribution of underlying noise sources, ...
1993-10-15
Remote temperature inversion sensor
International Nuclear Information System (INIS)
In conducting aircraft surveys for uranium, it is found that temperature inversions can give spurious results because they promote accumulation of radon gas in the atmosphere. The "2"1"4Bi (daughter product of radon) gamma-rays detected from the atmosphere-borne radon are difficult to separate from the "2"1"4Bi gamma-rays originating from the ground, and providing a signature for uranium deposits. The purpose of the present study was to examine the feasibility of making remote temperature soundings of the atmosphere below a low-flying aircraft (140 m or less above ground) by the inversion of radiance measurements taken in the 15-micron carbon dioxide absorption band. Such measurements would identify those temperature inversion conditions possibly leading to an unacceptably large background of gamma-rays from the atmospheric radon. Thus, the incidence of spurious aerial survey data could be greatly reduced. An atmospheric model was set up and ...
1977-01-01
Ozone production at the National Synchrotron Light Source
International Nuclear Information System (INIS)
Ozone production by synchrotron radiation as a function of power density in air was investigated using a white beam at the BNL National Synchrotron Light Source (NSLS) x-ray ring. Power densities were calculated from the energy spectrum at 2.52 GeV. Ozone concentrations in small beam pipes were measured for power densities between I = 10"1"2 and 10"1"5 eV . cm"-"3 . sec"-"1. The measured ozone half-life was 37 +- 2 min. The measured G-value was 2.69 +- 0.14 mol/100 eV and the ozone destruction factor k was less than 7 x 10"-"1"9 cm"3 . eV"-"1. The random uncertainties stated are approximately one standard error. The large departure of the values for G and k from previous values suggest that some undiscovered systematic error may exist in the experiment. Ozone concentration in excess of the 0.1 ppM ACGIH TLV can be generated in the experimental hutches but can readily be controlled. ...
1998-09-20
International Nuclear Information System (INIS)
Ozone production by synchrotron radiation as a function of power density in air was investigated using a white beam at the BNL National Synchrotron Light Source (NSLS) x-ray ring. Power densities were calculated from the energy spectrum at 2.52 GeV. Ozone concentrations in small beam pipes were measured for power densities between I = 10/sup 12/ and 10/sup 15/ eV/sup . /cm/sup -3 . /sec/sup -1/. The measured ozone half-life was 37+-2 min. The measured G-value was 2.69+-0.14 mol/100 eV and the ozone destruction factor k was less than 5 x 10/sup -19/cm/sup 3//eV. The random uncertainties stated are approximately one standard error. The large departure of the values for G and k from previous values suggest that some undiscovered systematic error may exist in the experiment. Ozone concentration in excess of the 0.1 ppm ACGIH TLV can be generated in the experimental hutches but can ...
International Nuclear Information System (INIS)
A method that employs simultaneous neutron and #gamma#-ray diffraction techniques is proposed for accurate measurements of strains with or without an applied electric field (0-100 kV m"-"1). Instead of an absolute determination of the position of the neutron Bragg peak, a relative measurement of the neutron and #gamma# peak positions is used and allows a determination of the lattice-parameter changes with an accuracy of within 2 x 10"-"6. This technique avoids systematic errors originating in sample rotations by taking advantage of a reference directly related to the crystal lattice. The method appears to be particularly important for crystals that exhibit structural phase transitions, as demonstrated by the measurement of the strain U_x_x in KH_2PO_4 crystals as a function of temperature and applied electric field. In this case the errors would amount to #+-#20%. The results ...
1987-12-01
Fluid temperature measurement technique by using Raman scattering
Energy Technology Data Exchange (ETDEWEB)
Temperature measurement technique by using Raman scattering was developed for the liquid water at temperature of 20 - 90 degree C and atmospheric pressure. Strong relationship between Raman scattering characteristics and liquid temperature change was observed. Various kinds of measurement techniques, such as Peak Intensity, Peak Wavelength, FWHM (Full Width at Half Maximum), PMCR ( Polymer Monomer Concentration RAte), TSIR (Temperature Sensitive Intensity Ratio), IDIA (Integral Difference Intensity Area) were tested. TSIR has the highest accuracy in mean error or 0.1 deg C and standard deviation of 0.1248 deg C. This report is one of the results in developing process of Raman temperature measurement technique. Next research step is to develop Raman temperature measurement technique at the high temperature and high pressure conditions in single or two phase flows. (author). 13 refs., ...
1999-06-01
Measuring equipment for the monitoring of air pollution control - a market review
Energy Technology Data Exchange (ETDEWEB)
The paper abstracted gives a tabular survey of the suppliers and applications of measuring equipment. Equipment is available for the following fields of application: Continuous measuring instruments for stationary operation, laboratory equipment for sampling and hand equipment for mobile measurement, sampling equipment for examining emissions and gases, detectors, storage and evaluation equipment and meteorological instruments. (PW).
1986-01-01
Measurement of time of travel in streams by dye tracing
Energy Technology Data Exchange (ETDEWEB)
The US Geological survey is active in measuring time of travel in streams using dye tracers. This manual describes methods of measuring time of travel of water and waterborne solutes by dye tracing. The fluorescent dyes, measuring equipment used, and field and laboratory procedures are also described. Methods of analysis and presentation to illustrate time of travel of streams are provided.
1989-01-01
Precise measurement of theta_13 at Daya Bay
The Daya Bay Reactor Neutrino Experiment is designed to determine the yet unknown neutrino mixing angle theta_13 by measuring the disappearance of electron antineutrinos from several nuclear reactor cores, using multiple underground detectors at different baselines to minimize systematic errors and to suppress the cosmogenic background. The civil construction has begun since October 2007, enabling first commissioning data in 2009, and full data taking will begin in late 2010. The planned sensitivity in sin^2 (2theta_13) of better than 0.01 at 90% CL will be achieved in three years of data-taking. I will present an overview and current status of the experiment.
2008-01-01
Natural convection cooling of circumferentially finned transport casks
International Nuclear Information System (INIS)
It may be stated that for the calculation of the heat transfer coefficients for natural convection cooling of large-diameter finned surfaces it is necessary to take in consideration the effects of the fin length, fin material and of the azimuthal angle around the cylinder. The present results replace earlier less accurate correlations gained from the same measurements. The new, better correlation was elaborated with the aid of the improved method of evaluation of multiple parameters of a measurement matrix of multiple dimension (one dimension for each parameter), rendering the sum of the squares error a minimum at the same time for the complete matrix. 5 references.
1983-12-01
Energy Technology Data Exchange (ETDEWEB)
The document describes the outcome of the CSN/CIEMAT-00 interlaboratory test comparison among environmental radioactivity laboratories. the exercise was organised according to the ISO-43 and the ISO/IUPAC/AOAC Harmonized Protocol for the proficiency testing of analytical laboratories. the test sample was a soil containing environmental levels of K-40, Ra-226, Ac-228, Sr-90, Cs-137, Cs-134, Pu (239-240) y Am-241. the Universidad Autonoma de Barcelona prepared the material and reported adequate statistical studies of homogeneity. The results of the exercise were computed for 30 participating laboratories, and their analytical performance was assessed using the u-score approach. A raised percentage of satisfactory laboratory performance has been obtained for all the analysis, being the best performance in gamma measurements. The exercise has drawn that several ...
2002-07-01
Energy Technology Data Exchange (ETDEWEB)
Measurements of human joint motion frequently involve the use of opto-electronic and other motion analysis systems where some type of makers are used to establish joint motion within a global reference coordinate frame. Typically, this global reference coordinate frame is chosen to be most convenient for the person carrying out the experiment in which the joint motion is measured, and Euler angles are chosen as the measure of joint motion. Results, however, may be quite arbitrary and therefore rendered meaningless if the reference frame is not properly chosen with respect to the physical joint axis. In order to make a proper choice of coordinate axes in the reference frame, one must take into consideration both the location and the orientation of die physical joint axis relative to the reference frame`s axes. In nature, joint axes can exist at any orientation and location relative to an arbitrarily chosen global reference ...
1995-02-01
... resolution video. RESULTS Statistics describing the typical inertial navigation error growth were collected. Typical errors ...
2008-08-06
Science and Technology Review July/August 2010
Energy Technology Data Exchange (ETDEWEB)
This issue has the following articles: (1) Deterrence with a Minimum Nuclear Stockpile - Commentary by Bruce T. Goodwin; (2) Enhancing Confidence in the Nation's Nuclear Stockpile - Livermore experts are participating in a national effort aimed at predicting how nuclear weapon materials and systems will likely change over time; (3) Narrowing Uncertainties - For climate modeling and many other fields, understanding uncertainty, or margin of error, is critical; (4) Insight into a Deadly Disease - Laboratory experiments reveal the pathogenesis of tularemia in host cells, bringing scientists closer to developing a vaccine for this debilitating disease. (5) Return to Rongelap - On the Rongelap Atoll, Livermore scientists are working to minimize radiological exposure for natives now living on or wishing to return to the islands.
2010-05-27
Application of a prognostic model validation system to real-time dispersion modeling
Energy Technology Data Exchange (ETDEWEB)
The Atmospheric Release Advisory Capability (ARAC) at the Lawrence Livermore National Laboratory uses the U.S. Navy's Coupled Ocean/Atmosphere Mesoscale Prediction System (COAMPS) to supply high-resolution wind data for use in its real-time dispersion modeling system. ARAC has used COAMPS products to support several events and exercises, and COAMPS forecasts appear accurate, based on qualitative examination. Recently ARAC has developed a quantitative verification system which calculates COAMPS error and bias statistics, comparing COAMPS forecasts of various lengths with observational data. This paper shows how this system has been used to guide ARAC operators, who need an estimate of the likely behavior of COAMPS forecasts of various lengths in different regions, seasons, and weather patterns.
1999-10-18
Precision Measurement of the Undulator K Parameter using Spontaneous Radiation
Energy Technology Data Exchange (ETDEWEB)
Obtaining precise values of the undulator parameter, K, is critical for producing high-gain FEL radiation. At the LCLS [1], where the FEL wavelength reaches down to 1.5 {angstrom}, the relative precision of K must satisfy ({Delta}K/K){sub rms} {approx}< 0.015% over the full length of the undulator. Transverse misalignments, construction errors, radiation damage, and temperature variations all contribute to errors in the mean K values among the undulator segments. It is therefore important to develop some means to measure relative K values, after installation and alignment. We propose a method using the angle-integrated spontaneous radiation spectrum of two nearby undulator segments, and the natural shot-to-shot energy jitter of the electron beam. Simulation of this scheme is presented using both ideal and measured undulator fields. By ''leap-frogging'' to ...
2007-04-17
Implementation of projective measurements with linear optics and continuous photon counting
International Nuclear Information System (INIS)
We investigate the possibility of implementing a given projection measurement using linear optics and arbitrarily fast feedforward based on the continuous detection of photons. In particular, we systematically derive the so-called Dolinar scheme that achieves the minimum-error discrimination of binary coherent states. Moreover, we show that the Dolinar-type approach can also be applied to projection measurements in the regime of photonic-qubit signals. Our results demonstrate that for implementing a projection measurement with linear optics, in principle, unit success probability may be approached even without the use of expensive entangled auxiliary states, as they are needed in all known (near-)deterministic linear-optics proposals.
2005-02-01
Design and operation of an apparatus for calorimetric emittance measurements of pipe surfaces
Energy Technology Data Exchange (ETDEWEB)
A technique for the measurement of the total hemispherical emittance of pipe surfaces is described, and design and operational details are given. The technique is conceptually simple. A long test pipe (e.g., 3.4 m) is mounted concentrically inside a Pyrex glass pipe. The system is evacuated, and the test pipe is heated by means of an electrical resistance heater. Heat transfer from the test pipe to the enclosure is almost solely radiative, allowing an average emittance for the test pipe and the Pyrex pipe and the electrical power input to the heater. By varying the electrical power level, one can measure the test pipe emittance as a function of temperature. By using a simple correction to account for the finite length of the test pipe, one can calculate the results using the simple expression for infinite, concentric cylinders. Results agree with measurements by reflectance techniques and have a nominal relative ...
1981-10-01
AC loss measurements of model and full size 50mm SSC collider dipole magnets at Fermilab
Energy Technology Data Exchange (ETDEWEB)
Tests have recently been performed at Fermilab in order to measure the energy losses due to eddy currents and iron and superconductor magnetization. These measurements were performed on six 1.5m long model magnets and eight 15m long full scale collider dipole magnets. AC losses were measured as a function of ramp rate using sawtooth ramps from 500, to 5000 Amps for both types of magnets, while bipolar studies were additionally performed on some of the short magnets. The measured magnet voltage and current for a complete cycle are digitally integrated to yield the energy loss per cycle. Measurement reproducibility is typically 5%, with good agreement between long magnet measurements and extrapolations from short magnet measurement results. Magnetization loss measurements among similar magnet types agree to within ...
1992-09-01
Beam emittance measurements of ORNL negative ion sources
Energy Technology Data Exchange (ETDEWEB)
The emittances of hydrogen and deuterium negative ion beams produced by volume ion sources have been measured in a transverse plane normal to the beam trajectory. The extraction voltage was varied from 10 to 40 kV, and the transverse magnetic field in the Penning discharges was varied from 0.1 to 0.2 T. Measurements were made on beams with current densities up to 60 mA/cm/sup 2/ at Oak Ridge National Laboratory with an emittance scanner originally developed at Los Alamos National Laboratory. The beam profile at the scanner can be used to improve the accuracy of the emittance measurements. Other factors affecting emittance measurements are discussed. This analysis may be applicable to other ion sources. 6 figs.
1989-01-01
HPA - Radon Calibration Facilities
... Radon gas concentrations are measured using instruments with calibrations traceable to the UK National Physical Laboratory and PTB, Germany. The primary facility is a 43 m3 walk-in chamber accessed by an airlock. Radon gas is maintained at a level in this chamber that is ...
Energy Technology Data Exchange (ETDEWEB)
There are various reasons for preferring local (e.g., three bump) orbit correction methods to global corrections. One is the difficulty of solving the mN equations for the required mN correcting bumps, where N is the number of superperiods and m is the number of bumps per superperiod. The latter is not a valid reason for avoiding global corrections, since, we can take advantage of the superperiod symmetry to reduce the mN simultaneous equations to N separate problems, each involving only m simultaneous equations. Previously, I have shown how to solve the general problem when the machine contains unknown magnet errors of known probability distribution; we made measurements of known precision of the orbit displacements at a set of points, and we wish to apply correcting bumps to minimize the weighted rms orbit deviations. In this report, we will consider two simpler problems, using similar methods. We consider the case when we make M beam ...
1987-11-01
Growth model and on-line measurement of pitting corrosion on carbon steel
Energy Technology Data Exchange (ETDEWEB)
A growth model of pitting corrosion of carbon steel in cooling water systems was developed on microscopic observations of pits and electrochemical studies. Results of pitting corrosion measurements in laboratory and field conditions with the model, using a newly developed electrochemical device, are discussed. For an actual heat exchanger up to a year operation, the values of pitting depth estimated were in good agreement with the measured values.
1996-12-01
Energy Technology Data Exchange (ETDEWEB)
The Mixed Waste Landfill occupies 2.6 acres in the north-central portion of Technical Area 3 at Sandia National Laboratories, Albuquerque, New Mexico. The landfill accepted low-level radioactive and mixed waste from March 1959 to December 1988. This report represents the Corrective Measures Study that has been conducted for the Mixed Waste Landfill. The purpose of the study was to identify, develop, and evaluate corrective measures alternatives and recommend the corrective measure(s) to be taken at the site. Based upon detailed evaluation and risk assessment using guidance provided by the U.S. Environmental Protection Agency and the New Mexico Environment Department, the U.S. Department of Energy and Sandia National Laboratories recommend that a vegetative soil cover be deployed as the preferred corrective measure for the Mixed Waste Landfill. The cover would be ...
2004-03-01
The decay modes $\\jpsi\\ar\\gamma\\pi^0, \\gamma\\eta$ and $\\gamma\\etap$ are analyzed using a data sample of 58 million $\\jpsi$ decays collected with the BESII detector at BEPC. The branching fractions are determined to be: $Br(\\jpsi\\ar\\gamma\\pi^0)=(3.13^{+0.65}_{-0.44})\\times10^{-5}$, $Br(\\jpsi\\ar\\gamma\\eta)=(11.23\\pm0.89)\\times10^{-4}$, and $Br(\\jpsi\\ar\\gamma\\etap)=(5.55\\pm0.44)\\times10^{-3}$, where the errors are combined statistical and systematic errors. The ratio of partial widths $\\Gamma(\\jpsi\\ar\\gamma\\etap)/\\Gamma(\\jpsi\\ar\\gamma\\eta)$ is measured to be $4.94\\pm0.40$, and the singlet-octet pseudoscalar mixing angle of $\\eta-\\etap$ system is determined to be $\\theta_{P}=(-22.08\\pm0.81)^{\\circ}$.
2006-01-01
Development of the discrete-time adaptive sliding mode power system stabilizer
Energy Technology Data Exchange (ETDEWEB)
A newly developed discrete-time adaptive sliding mode power system stabilizer (PSS) is proposed in this paper. Because the proposed PSS is developed in the pure discrete-time domain it is able to maintain the stability with the rather slower smapling frequency compared to discretized conventional continuous-time sliding mode PSS. The proposed PSS has the three main superiorities to the conventional PSS. First, because the proposed PSS utilizes the sliding mode control method, it has the strong robustness to the variations of the system parameters. Hence, it can overcome the minor disturbances such as identification errors, modeling errors, etc. Second, the proposed PSS needs only input/output measurements as feedback signals. Hence, it does not need the measurements of the state variables as the conventional sliding mode PSS or PSS based on the linear quadratic control method does. Finally, because the ...
1996-12-31
Control of linear accelerator noise in the Los Alamos free-electron laser (FEL)
International Nuclear Information System (INIS)
The Los Alamos FEL requires tight control of the amplitudes and phases of the fields in two linear accelerator tanks to obtain stable lasing. The accelerator control loops must establish constant, stable, repeatable amplitudes and phases of the rf fields and must have excellent bandwidth to control high-frequency noise components. A model of the feedback loops has been developed that agrees well with measurements and allows easy substitution of components and circuits, thus reducing breadboarding requirements. The model permits both frequency and time-domain analysis. This paper describes the accelerator control scheme and our model and discusses the control of noise in feedback loops, showing how low-frequency-noise components (errors) can be corrected, but high-frequency-noise components (errors) are actually amplified by the feedback circuit. Measurements of noise in both open- and closed-loop modes ...
1986-06-02
A method of predicting pressure profiles in horizontal 37-element clusters
International Nuclear Information System (INIS)
A new two-phase friction multiplier correlation has been developed to predict the pressure profile in two-phase flow with heat addition. The main difference from other pressure drop prediction routines is that in addition to the effect of quality, the effects of system pressure, heat and mass flux on the two-phase multiplier are included. The inception of two-phase flow is defined to occur at the onset of significant void in the subcooled boiling regime instead of the boundary between negative and positive thermodynamic equilibrium quality. Pressure drop data from an experiment with a fully segmented 6-metre long, 37-element fuel string were used to optimize the constants and exponents of this correlation for the friction multiplier. This pressure drop prediction technique was shown to successfully predict the measured pressure profiles. The more than one hundred overall pressure drop data were predicted with an RMS error of 5.4 percent. The ...
1983-04-18
International Nuclear Information System (INIS)
Purpose: To develop an accurate, fast, and robust algorithm for registering portal and computed tomographic (CT) images for radiotherapy using a combination of sparse and dense field data that complement each other. Methods and Materials: Gradient Feature Weighted Minimax (GFW Minimax) method was developed to register multiple portal images to three-dimensional CT images. Its performance was compared with that of three others: Minimax, Mutual Information, and Gilhuijs' method. Phantom and prostate cancer patient images were used. Effects of registration errors on tumor control probability (TCP) and normal tissue complication probability (NTCP) were investigated as a relative measure. Results: Registration of four portals to CTs resulted in 30% lower error when compared with registration with two portals. Computation time increased by nearly 50%. GFW Minimax performed the best, followed by Gilhuijs' method, the Minimax ...
2006-06-01
Status of measurements of fission neutron spectra of Minor Actinides
International Nuclear Information System (INIS)
The report considers experimental and theoretical works on studying the energy spectra of prompt neutrons emitted in spontaneous fission and neutron induced fission of Minor Actinides. It is noted that neutron spectra investigations were done for only a small number of such nuclei, most measurements, except those of Cf-252, having been carried out long ago by obsolete methods and imperfectapparatus. The works have no detailed description of experiments, analysis of errors, detailed numerical information about results of experiments. A conclusion is made that the available data do not come up to modern requirements. It is necessary to make new measurements of fission prompt neutron spectra of transuranium nuclides important for the objectives of working out a conception of minor actinides transmutation by means of special reactors. (author).
1997-03-01
Quantitative measurement of elements in a composite, using multienergy gamma-rays
International Nuclear Information System (INIS)
This study is an attempt to measure the quantities of elements in a composite by irradiating that composite with #gamma#-rays of various energies and detecting the transmitted radiation through the composite. A previous knowledge of the number of the elements and their attenuation coefficients is required. The quantities are calculated by solving the matrix of a linear system of equations. A computer program was developed to select the best combinations of the available energies. Five criteria were established to determine these energy combinations: (i) the determinant of the attenuation coefficient matrix; (ii) the condition number, (iii) the number of times the solution of the matrix leads to acceptable results; (iv) the indicator, (a new concept); (v) the standard deviations of the results. The intended application of this technique in medicine is to measure the bone mineral content of the skeleton. An examination of the ...
International Nuclear Information System (INIS)
A Quantitative Computed Tomography (QCT) method, simplifying the well-known technique proposed by Genant (1982) and applied to a standard third generation whole body CT scanner is described. This technique was applied in the measurement of the trabecular bone which has high sensitivity for metabolic changes. The BMC (Bone Mineral Content) measured in different groups of subjects (healthy postmenopausal patients versus women with postmenopausal osteoporosis) showed a highly significant difference (p<0.001). The precision of repositioning (coefficient of variation 1.8% to 2.3%, obtained in healty male patients) and the good, linear relationship computed from the phantom values, minimize measurement errors. Since this method is quickly applied and involves low-dose radiation-exposure, it could be introduced in the clinical study of metabolic bone diseases.
1987-01-01
International Nuclear Information System (INIS)
This article describes the laser Thomson scattering principle and the developed system on HL-2A device. The high power Q-switch Nd:YAG laser, with a wavelength of 1064 nm, can sufficiently satisfy the measurement requirement. The polycromator consisting of avalanche photo-diodes(APD) and narrow band interference filters, can effectively improve the measurement of scattering light. The electron temperature is deduced by error-weighted lookup table method, which improves the data- processing speed or efficiency. Finally, the experiment results of the one-point electron temperature during different discharges of plasma are presented. (authors)
2008-07-01
International Nuclear Information System (INIS)
A consideration is given to the problem of selecting optimized methods of radionuclide radiation registration during the control of the objects with essential changes in thickness. Adequate model of information signal formation is developed and analyzed for the case of the existence of an inertial link of the system with the dead time of a noncontinued type. The boundary values of radiation thickness and radiation flux intensity that divide the priority of using either digital or analog registration modes are revealed. The method is found for the full correction of a systematic error of flux intensity measurement because of the dead time of the apparatus. To control the objects with essential variation of thickness the method of selective measurement of radiation intensity is proposed
A measurement of the parity-violating gamma-ray asymmetry in the neutron-proton capture
Energy Technology Data Exchange (ETDEWEB)
The {rvec n} + p {yields} d + {gamma} experiment under construction at LANSCE studies the weak interaction between neutrons and protons. The experiments will measure the directional dependence of the parity-violating {gamma}-ray asymmetry, A{sub {gamma}}, in the polarized cold neutron capture by para-hydrogen. The goal is to measure A{sub {gamma}} with uncertainty of 0.5 x 10{sup -8}, 10% of its predicted value. A{sub {gamma}} primarily isolates the {Delta}I = 1 component of the hadronic weak interaction and thus will determine the long-range weak pion-nucleon coupling constant H{sub {pi}}{sup 1}. The experiment is carefully designed for the LANSCE pulsed spallation neutron source to achieve the proposed statistical precision and to control systematic errors. We discuss the experiment and its status.
2002-01-01
Visualization of two-phase flow eddies in rectangular channels using real-time neutron radiography
Energy Technology Data Exchange (ETDEWEB)
Bubbly and slug flows have been analyzed using the afore-mentioned techniques. An image series of bubbly-slug flow is shown. The image separation time is 17 ms, and the total flow length is {approx} 10 cm. A circular eddy pattern that follows the slug can be readily seen and tracked, although reliability is low due to motion in the transverse direction. This motion also adds considerable error to the velocity measurements using image recognition technique. This will increase the reliability and accuracy of the tracking method.
1994-12-31
Tolerance limits of X-ray image intensity
International Nuclear Information System (INIS)
Evaluation of the tolerance limits of X-ray image density accepted by the radiologist shows that for different kinds of examinations, deviations of more than 50% from optimal density lead to images which cannot be used diagnostically. Within this range diagnostic accuracy shows a distinct maximum and diminishes to the limits by 20%. These figures are related to differences in the intensifying factor of screens, sensitivity of films, sensitometric parameters of film processing as well as the doses employed with automatic exposure control devices, measured in clinical conditions. Maximum permissible tolerance limits of the whole imaging system and of its constituents are discussed using the Gaussian law of error addition. (author).
The Daya Bay Neutrino Oscillation Experiment
British Library Electronic Table of Contents (United Kingdom)
The search for the mixing angle Formula Not Shown , the last unknown angle in the neutrino mixing matrix, is one of the main priorities in the field of neutrino physics. By measuring Formula Not Shown to better than 0.01 at 90% C.L., the Daya Bay Reactor Neutrino Experiment has the highest sensitivity to this parameter among all the other experiments that are currently operating or under construction. The experiment consists of multiple identical detectors placed underground at different baselines from three groups of reactors, a configuration that minimizes systematic errors and cosmogenic backgrounds. The main aspects of the experiment, as well as its current status and future prospects, are reviewed.
2011-01-01
Risk Premium Impact in the Perturbative Black Scholes Model
We study the risk premium impact in the Perturbative Black Scholes model. The Perturbative Black Scholes model, developed by Scotti, is a subjective volatility model based on the classical Black Scholes one, where the volatility used by the trader is an estimation of the market one and contains measurement errors. In this article we analyze the correction to the pricing formulas due to the presence of an underlying drift different from the risk free return. We prove that, under some hypothesis on the parameters, if the asset price is a sub-martingale under historical probability, then the implied volatility presents a skewed structure, and the position of the minimum depends on the risk premium $\\lambda$.
2008-01-01
The ultimate compressive strength of 36 thoracolumbar vertebrae was determined experimentally. In addition, the trabecular bone mineral content was measured by single energy quantitative computed tomography. The areas of fractured endplates were also determined by computed tomography. The results show that a linear relationship exists between the compressive strength and the product of bone density and endplate area. These data allow an in vivo prediction of vertebral body strength using a noninvasive method with a standard error of estimate amounting to less than 0.95 kN. PMID:3212488
1988-01-01
Performance Comparisons of PSO based Clustering
In this paper we have investigated the performance of PSO Particle Swarm Optimization based clustering on few real world data sets and one artificial data set. The performances are measured by two metric namely quantization error and inter-cluster distance. The K means clustering algorithm is first implemented for all data sets, the results of which form the basis of comparison of PSO based approaches. We have explored different variants of PSO such as gbest, lbest ring, lbest vonneumann and Hybrid PSO for comparison purposes. The results reveal that PSO based clustering algorithms perform better compared to K means in all data sets.
2010-01-01
Observation of p pbar pi^0 and p pbar eta in psi' decays
The processes psi'-->p pbar pi^0 and psi'-->p pbar eta are studied using a sample of 14 million psi' decays collected with the Beijing Spectrometer at the Beijing Electron-Positron Collider. The branching fraction of psi'-->p pbar pi^0 is measured with improved precision as (13.2\\pm 1.0\\pm 1.5)\\times 10^{-5}, and psi'-->p pbar eta is observed for the first time with a branching fraction of (5.8\\pm 1.1\\pm 0.7)\\times 10^{-5}, where the first errors are statistical and the second ones are systematic.
2005-01-01
Measurement of the Matrix Element for the Decay $\\eta^{\\prime} \\to \\eta \\pi^+\\pi^-$
The Dalitz plot of $\\eta^{\\prime} \\to \\eta \\pi^+ \\pi^-$ decay is studied using $(225.2\\pm2.8)\\times 10^6$ $\\jpsi$ events collected with the BESIII detector at the BEPCII $e^+e^-$ collider. With the largest sample of $\\eta^{\\prime}$ decays to date, the parameters of the Dalitz plot are determined in a generalized and a linear representation. Also the branching fraction of $\\jpsi \\to \\gamma \\eta^{\\prime}$ is determined to be $(4.84\\pm0.03\\pm0.24)\\times 10^{-3}$, where the first error is statistical and the second systematic.
2010-01-01
Measurement of stress in materials using chromium K/sub. beta. / radiation
Energy Technology Data Exchange (ETDEWEB)
Bragg peaks obtained in X-ray stress analysis studies are often asymmetric. The use of K/sub ..beta../ rather than K/sub ..cap alpha../ radiation simplifies the problem of peak location, as only one Bragg peak needs to be analysed. It is shown, however, that the common practice of fitting a parabola to the top 15% of the data in a Bragg peak in order to determine the peak position, when the fitted region is asymmetric, can lead to large errors in the calculated stress. Asymmetric pseudo-Lorentzian functions have been found to provide the most satisfactory fits.
1983-01-01
Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposed
British Library Electronic Table of Contents (United Kingdom)
Objective: Results of reliability and agreement studies are intended to provide information about the amount of error inherent in any diagnosis, score, or measurement. The level of reliability and agreement among users of scales, instruments, or classifications is widely unknown. Therefore, there is a need for rigorously conducted interrater and intrarater reliability and agreement studies. Information about sample selection, study design, and statistical analysis is often incomplete. Because of inadequate reporting, interpretation and synthesis of study results are often difficult. Widely accepted criteria, standards, or guidelines for reporting reliability and agreement in the health care and medical field are lacking. The objective was to develop guidelines for reporting reliability and...
2011-01-01
Electron temperature diagnostics in the RFX reversed field pinch experiment
Energy Technology Data Exchange (ETDEWEB)
The paper presents an integrated approach to the problem of electron temperature diagnostics of the plasma in a reversed field pinch. Three different methods, sampling different portions of the electron distribution function, are adopted, namely Thomson scattering, soft X-ray spectroscopy by pulse-height analysis and filtered soft X-ray intensity ratio. A careful analysis of the different sources of systematic errors is performed and a novel statistical approach is adopted to mutually validate the three independent measurements. A satisfactory agreement is obtained over a large range of experimental conditions, indicating that in the plasma core the energy distribution function is well represented by a maxwellian. (author)
2000-08-01
Dosimetry limitations and a dose correction methodology for step-and-shoot IMRT
Energy Technology Data Exchange (ETDEWEB)
For the step-and-shoot intensity-modulated radiation therapy (IMRT) technique, the combination of high dose rate, multiple beam segments and low dose per segment can lead to significant differences between the planned dose and the dose delivered to the patient. In this technique, a dose delivery inaccuracy known as the 'overshoot' effect is caused by the dose servo control system. This typically occurs in the first and last beam segments and causes an over- and underdose, respectively. Some dose positional error in the segment sequence is also possible there. Commercial ionization chambers (RK-type) and radiographic Kodak films were used for the measurements. The reported results were obtained using the Pinnacle{sup 3}-V6.2 treatment planning system and a Varian Clinac 21 EX linear accelerator equipped with a 120-leaf Millennium MLC. The dose inaccuracy measurements were based on the comparison of the dose ...
2006-02-07
Energy Technology Data Exchange (ETDEWEB)
The use of the method is described on powder samples before and after sintering with a La content of up to 1%. For excitation of the K series of La a /sup 241/Am source with an activity of 1.11 GBq was used. The obtained results showed that the method is sufficiently accurate (error 7%) at a short period of measurement (100 s). It gives satisfactory results even in the comparison of the experimental relative count rate and the theoretically calculated value despite the fact that the analytical signal comes from the sample surface.
1983-05-01
International Nuclear Information System (INIS)
The use of the method is described on powder samples before and after sintering with an La content of up to 1%. For excitation of the K series of La a _2_4_1Am source with an activity of 1.11 GBq was used. The obtained results showed that the method is sufficiently accurate (error 7%) at a short period of measurement (100 s). It gives satisfactory results even in the comparison of the experimental relative count rate and the theoretically calculated value despite the fact that the analytical signal comes from the sample surface. (Ha).
1983-01-01
A Geometrical Model for Non-Zero $\\theta_{13}$
Based on Friedberg and Lee's geometric picture by which the tribimaximal PMNS leptonic mixing matrix is constructed, namely corresponding mixing angles correspond to the geometric angles among the sides of a cube. We suggest that the three realistic mixing angles which slightly deviate from the values determined for the cube, are due to a viable deformation from the perfectly cubic shape. Taking the best fitted results of $\\theta_{12}$ and $\\theta_{23}$ as inputs, we determine the central value of $\\sin^22\\theta_{13}$ should be 0.0238 with a relatively large error tolerance, this value lies in the range of measurement precision of the Daya Bay experiment.
2011-01-01
The SUERC AMS laboratory after 3 years
British Library Electronic Table of Contents (United Kingdom)
The new SUERC AMS Laboratory was described at AMS-9. Since then there have been technological developments, added and improved analysis capability, the formation of additional complementary groups, the purchase of another instrument, and many samples measured. Be, C, Al, Cl, Ca and I-AMS are established with measured species changing weekly. Full-terminal potential running is now routine and 5MV is proving sufficient for all species. Ion detection and evaluation has also been improved by the use of even thinner detector windows as necessary and a more powerful on-line data analysis system. Routine radiocarbon measurement is to 4permil reproducibility at middling current and graphite samples of as little as 100mg C can be accommodated. Even smaller samples can be measured as CO2 using He ca...
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
Researchers at the Laboratory of Nuclear Microanalysis in Besancon (France) are developing and improving radon measurements in order to detect and analyse, more precisely radon emanation anomalies in both fields of Earth Sciences and Radioprotection. In order to characterize radon emanation, two complementary techniques are developed; continuous measurement through a portable proportional counter and passive measurements by nuclear track detectors for both fieldwork and laboratory analysis. A mathematical model is being devised to interpret the nuclear track detector response. This model is performed according to the device characteristics: type of detectors, shape and size of cells and whether a membrane is used or not. In addition to the theoritical study, experimental radon concentration measurements will be reported. (author).
1993-12-31
International Nuclear Information System (INIS)
Researchers at the Laboratory of Nuclear Microanalysis in Besancon (France) are developing and improving radon measurements in order to detect and analyse, more precisely radon emanation anomalies in both fields of Earth Sciences and Radioprotection. In order to characterize radon emanation, two complementary techniques are developed; continuous measurement through a portable proportional counter and passive measurements by nuclear track detectors for both fieldwork and laboratory analysis. A mathematical model is being devised to interpret the nuclear track detector response. This model is performed according to the device characteristics: type of detectors, shape and size of cells and whether a membrane is used or not. In addition to the theoritical study, experimental radon concentration measurements will be reported. (author).
Energy Technology Data Exchange (ETDEWEB)
Today`s nuclear power plants are marked by increasing needs for non-destructive inspection techniques in preventive maintenance programs. Additionally, it is becoming more important to evaluate residual stress which may be a key parameter for crack propagations in welded pipings. The authors have developed an ultrasonic velocity measurement method which obtains ultrasonic velocity changes by residual stress with a high accuracy. The ultrasonic velocity measurement is composed of three procedures. They are as follows. (1) Highly accurate propagation time measurements; (2) Pipe thickness correction; (3) Residual stress evaluation. The ultrasonic velocity measurements have been applied to the residual stress evaluation of carbon steel welded pipings. Destructive testing using stress strain gauges was done after the ultrasonic non-destructive evaluation of the residual stress. The experimental results ...
1995-08-01
Energy Technology Data Exchange (ETDEWEB)
To utilize solar energy effectively, a method has been developed by which daily clearness indexes can be estimated from phrase of general weather condition, and it has been examined at four places located at different typical climatic divisions in Japan. Successive results of extra-terrestrial solar insulation and measured solar insulation were illustrated at each place. It was found that the envelope of maximal value among measured values is in proportion to the extra-terrestrial solar insulation. Based on the basic clearness index and the meaning of term expressing general weather condition defined by the Meteorological Agency, the general weather condition was quantitated using the clearness index. This value was defined as weather index. Relationship between the measured clearness index at each place and the weather index was analyzed regressively. Correlation between the both was highly close, proportionally. ...
1997-07-31
Microclimatic conditions at the external surface of building envelopes
Energy Technology Data Exchange (ETDEWEB)
The project is described, the motivation for the research and the microclimate is defined in relation to both building physics research and applications. Air temperatur, air humidity, solar radiation and air velocity are briefly considered, whilst driving rain and long-wave radiation are described in more detail. Convective heat transfer and surface coefficients are discussed, although they are not microclimatic factors, merely resulting from combinations of such factors. They are included as they are important in relation to transfer of heat and moisture at the surface of the building envelope. Driving rain measurement is the main area of interest, including development of measurement equipment. Long-wave irradiation is measured and compared with empirical formulae from the literature. Window convection heat transfer is another main area of interest. Nocturnal convective heat transfer from a double pane glazing is studied ...
1998-12-31
Development of BWR core flow measurement technology using in-core neutron fluctuating signals
Energy Technology Data Exchange (ETDEWEB)
The extensive work on the measurement technology of total and local flow rates in BWR core has been performed using in-core neutron fluctuating signals. Based on a large amount of actual data acquired from commercial BWR plants in operation, physical interpretation was discussed on the transit time of the neutron fluctuating signals. The new findings against the logical inconsistency of the transit time between the different LPRM detector positions lead to a promised core flow measurement algorithm using in-core neutron fluctuating signals. The advanced on-line core flow measurement system was developed and tested during the startup phase of the first ABWR. The measurement test results demonstrate the present core flow measurement system within the errors of 5 through 10% over the wide operating area besides the capability for the local void fraction and ...
1997-09-01
A survey of community members' perceptions of medical errors in Oman
UK PubMed Central (United Kingdom)
BackgroundErrors have been the concern of providers and consumers of health care services. However, consumers' perception of medical errors in developing countries is rarely explored....Full Text Available
FY 1992 Measurements and Characterization Branch annual report
Energy Technology Data Exchange (ETDEWEB)
The Measurements and Characterization Branch actively supports the advancement of DOE/NREL goals for the development and implementation of the solar photovoltaic (PV) technology. The primary focus of the laboratories is to provide state-of-the-art analytical capabilities for materials and device characterization and fabrication. The branch houses a comprehensive facility that Is capable of providing information on the full range of PV components. A major objective of the branch is to aggressively pursue collaborative research with other government laboratories, universities, and industrial firms for the advancement of Pv technologies. Members of the branch disseminate research findings to the technical community in publications and presentations. The Measurements and Characterization Branch encompasses seven coordinated research groups, providing integrated research and development that covers all ...
1993-03-01
Three-dimensional, three-component wall-PIV
Energy Technology Data Exchange (ETDEWEB)
This paper describes a new time-resolved three-dimensional, three-component (3D-3C) measurement technique called wall-PIV. It was developed to assess near wall flow fields and shear rates near non-planar surfaces. The method is based on light absorption according to Beer-Lambert's law. The fluid containing a molecular dye and seeded with buoyant particles is illuminated by a monochromatic, diffuse light. Due to the dye, the depth of view is limited to the near wall layer. The three-dimensional particle positions can be reconstructed by the intensities of the particle's projection on an image sensor. The flow estimation is performed by a new algorithm, based on learned particle trajectories. Possible sources of measurement errors related to the wall-PIV technique are analyzed. The accuracy analysis was based on single particle experiments and a three-dimensional artificial data set simulating a rotating ...
2010-06-15
Proton emission in reaction of 14.6 MeV neutrons with natural iron
Energy Technology Data Exchange (ETDEWEB)
The energy spectra and angular distributions of proton emission in a reaction of {sup nat}Fe(n,xp) at a neutron energy of 14.6 MeV are measured by the University of Science and Technology of China multitelescope system. The double-differential cross sections of 16 reaction angles from 25 to 164.5 deg are obtained in this measurement. The statistical errors are reduced largely because of the thick target used. The angular distributions show a slightly energy-dependent forward-backward asymmetry. The angle-integrated proton spectrum is compared with theoretical calculations and other results. The total proton-emission cross section is in fair agreement with the prediction and evaluation.
1996-01-01
International Nuclear Information System (INIS)
An instrumental neutron activation technique of determining molybdenum in ores is based on measuring gamma-activity of the "9"9Mo isotope with the use of planar and coaxial semiconductor spectrometers. A lot consisting of 50 portions, 0.5 g each, is being irradiated for 10 hours by a flow of neutrons with the density of 10"1"2 n/cm"2xsec. On the lot being allowed to stay for 3-4 days, its activity is measured during 1-5 minutes. Monoethalons based upon phenol-formaldehyde resin are used as standards. The sensitivity of the technique is 10"-"4%, reproducibility error being not higher than 10%, efficiency up to 50 portions for a working shift.
First measurements of J/Psi decays into $\\Sigma^+ \\bar{\\Sigma}^-$ and $\\Xi^0 \\bar{\\Xi}^0$
Based on 58 million J/Psi events collected with the BESII detector at the BEPC, the baryon pair processes J/Psi to $\\Sigma^+ \\bar{\\Sigma}^-$ and J/Psi to $\\Xi^0 \\bar{\\Xi}^0$ are observed for the first time. The branching fractions are measured to be ${\\cal B}(J/Psi to \\Sigma^+ \\bar{\\Sigma}^-)=(1.50\\pm 0.10\\pm 0.22)\\times 10^{-3}$ and ${\\cal B}(J/Psi to \\Xi^0 \\bar{\\Xi}^0)=(1.20\\pm 0.12\\pm 0.21)\\times 10^{-3}$, where the first errors are statistical and the second ones are systematic.
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
The Advanced Photon Source injector synchrotron is a 7-GeV positron machine with a standard alternating gradient lattice. The calculated effect of dipole magnet strength errors on the orbit distortion, simulated by Monte Carlo, was reduced by sorting pairs of magnets having the closest simulated measured strengths to reduce the driving the term of the integer resonance nearest the operating point. This method resulted in a factor of four average reduction in the rms orbit distortion when all 68 magnets were sorted at once. The simulated effect of magnet measurement experimental resolution was found to limit the actual improvement. The {Beta}-beat factors were similarly reduced by sorting the quadrupole magnets according to their gradients.
1993-07-01
The economic benefits of supplemental fuel injections depend, in part, on the coke replacement ratio. An assessment of the accuracy with which blast furnace coke rate may be measured and a determination of the key drivers of coke rate uncertainty are offered, to provide guidance for experiments in high-rate gas injection. Using statistical analysis tools, an expression for the measurement error associated with the various terms of blast furnace carbon balance is developed. Coke rate calculations based on the material balance are most sensitive to coke carbon content and to proper tracking of hot metal tapping schedule.
1992-09-01
Burn-up measurement of irradiated nuclear fuel by means of micro-gamma scanning
International Nuclear Information System (INIS)
The Cs-137 radioactivity of a neutron-irradiated nuclear fuel sample has been measured by means of a micro-gamma scanning system which is associated with a high purity Ge detector. Subsequently the burn-up has been calculated from the Cs-137 radioactivity data and then compared with the values from the theoretical computation and chemical anaylsis. The burn-up value obtained with the gamma-scanning system seems to be reasonably agreeable with that of the chemical anaylsis provided that the statistical error in the experiments is taken into account. It is revealed that the burn-up data from the theoretical approach is slightly higher than those of micro-gamma scanning and chemical analysis methods. (Author).
We present in this article a detailed quantitative discussion of the measurement of the leptonic mixing angle theta_13 through currently scheduled reactor neutrino oscillation experiments. We thus focus on Double Chooz (Phase I & II), Daya Bay (Phase I & II) and RENO experiments. We perform a unified analysis, including systematics, backgrounds and accurate experimental setup in each case. Each identified systematic error and background impact has been assessed on experimental setups following published data when available and extrapolating from Double Chooz acquired knowledge otherwise. After reviewing the experiments, we present a new analysis of their sensitivities to sin^2(2 theta_13) and study the impact of the different systematics based on the pulls approach. Through this generic statistical analysis we discuss the advantages and drawbacks of each experimental setup.
2007-01-01
A compensating method of an imaging plate response to clinical proton beams
Energy Technology Data Exchange (ETDEWEB)
For charged particle irradiations, the response of an imaging plate (IP) changes around the Bragg peak. Therefore, an appropriate compensation is necessary for the evaluation of dose distribution formed by charged particles such as protons. In this paper, the response of IPs to clinical proton beams is investigated. An experimentally-obtained depth-dose distribution (an ordinary Bragg curve) by a silicon semiconductor detector (SSD) is employed to evaluate the compensation factors as a function of proton penetrating depth, i.e. residual range. A typical dose distribution in a water phantom formed by an L-shaped bolus is measured by IPs and corrected by using the information of those compensation factors; the residual proton range is successfully calculated by the pencil beam algorithm at an arbitrary point. The results show a good agreement with the measurements by the SSD within the rms error of 3.0%.
2002-04-01
Verification of electron beam therapy with storage phosphor images: Precision of field placement
Energy Technology Data Exchange (ETDEWEB)
Portal verification images were generated from the photon contamination in electron beams produced by a linear accelerator during treatment of patients receiving high-energy electron radiation therapy (8-14 MeV). An experimental storage phosphor system was used to record the images and display them on laser-printed film. Images were obtained from four or more treatment fractions from 21 cases of head and neck cancer. Precision in field placement was estimated by determining the position of a selected anatomic landmark relative to the center of the field for each series of images. The average standard deviation in the field-position measurements was 3.8 mm. Several procedural problems were also detected and corrected after review of the verification images. The results indicate that the emphasis placed on monitoring and control of field-positioning error in high-energy electron treatments should be similar to the emphasis placed on this aspect ...
1990-04-01
Structure of molten alkali halides
Energy Technology Data Exchange (ETDEWEB)
The results of X-ray and neutron diffraction experiments on molten alkali halides in which some data of our experiments by X-ray diffraction such as those of molten LiCl, NaCl, KCl, LiBr and KBr are included were summarized. The first peak positions in the radial distribution function in molten alkali halides by X-ray or neutron diffraction experiments are always longer than those by computer simulations and the differences of 0.1 -- 0.3 A exceed the experimental error. It seems to be due to the deformation of the electron shell. In the computer simulation, the shell model which has the spherical deformation was expected to have a closer value of the first peak position to the experimental one than the rigid ion model by taking the polarization of ions. However, no change in the first peak position was found. Therefore, the non-spherical deformation of electron shell at the point where ions are in contact with each other has to be taken into account. The neutron ...
1982-06-01
Structure of molten alkali halides
International Nuclear Information System (INIS)
The results of X-ray and neutron diffraction experiments on molten alkali halides in which some data of our experiments by X-ray diffraction such as those of molten LiCl, NaCl, KCl, LiBr and KBr are included were summarized. The first peak positions in the radial distribution function in molten alkali halides by X-ray or neutron diffraction experiments are always longer than those by computer simulations and the differences of 0.1 -- 0.3 A exceed the experimental error. It seems to be due to the deformation of the electron shell. In the computer simulation, the shell model which has the spherical deformation was expected to have more closer value of the first peak position to the experimental one than the rigid ion model by taking the polarization of ions. However, no change in the first peak position was found. Therefore, the non-spherical deformation of electron shell at the point where ions are in contact with each other has to be taken into account. The neutron ...
1982-01-01
Firewall Configuration Errors Revisited
The first quantitative evaluation of the quality of corporate firewall configurations appeared in 2004, based on Check Point FireWall-1 rule-sets. In general that survey indicated that corporate firewalls were often enforcing poorly written rule-sets, containing many mistakes. The goal of this work is to revisit the first survey. The current study is much larger. Moreover, for the first time, the study includes configurations from two major vendors. The study also introduce a novel "Firewall Complexity" (FC) measure, that applies to both types of firewalls. The findings of the current study indeed validate the 2004 study's main observations: firewalls are (still) poorly configured, and a rule-set's complexity is (still) positively correlated with the number of detected risk items. Thus we can conclude that, for well-configured firewalls, ``small is (still) beautiful''. However, unlike the 2004 study, we see no significant indication that later software versions ...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
X-ray fluorescence (XRF) and total-reflection X-ray fluorescence (TXRF) techniques suited well for a multi-element determination of K, Ca, Mn, Fe, Cu, Zn, Rb, and Sr in some Syrian medicinal plant species. The accuracy and the precision of both techniques were verified by analyzing the Standard Reference Materials (SRM) peach-1547 and apple leaves-1515. A good agreement between the measured concentrations of the previously mentioned elements and the certified values were obtained with errors less than 10.7% for TXRF and 15.8% for XRF. The determination of Br was acceptable only by XRF with an error less than 24%. Furthermore, the XRF method showed a very good applicability for the determination of K, Ca, Mn, Fe, Cu, Zn, Rb, Sr, and Br in infusions of different Syrian medicinal plant species, namely anise (Anisum vulgare), licorice root (Glycyrrhiza glabra), and white wormwood (Artemisia herba-alba)
2009-07-15
Contributions to the Analysis of Spatial and Spatial-Temporal Data
Energy Technology Data Exchange (ETDEWEB)
This doctoral thesis addresses some problems in the analysis of spatial and spatial-temporal data and discusses prediction, prediction errors and identification of emission sources. European sulphur data are used as illustration. In an investigation of a spatial-temporal decomposition model for improving estimates of spatial interpolation (prediction) errors from monitoring data, the estimates were improved compared to estimates obtained by the method known as Kriging (an extension of the Wiener-Kolmogorov theory from time series to spatial processes), although the interpolated values were quite similar. A study of a random process model with an unknown, slowly varying trend and a correlated residual process is performed, using both trend estimation (smoothing) and prediction. Local polynomial methods are extended to continuous random processes. A new approach to non-parametric smoothing and to non-parametric Kriging is described. Finally, a ...
1996-12-31
Intercomparison of irradiance measurements based on WRR and ETL irradiance scales
Energy Technology Data Exchange (ETDEWEB)
We report the corrected intercomparison of the World Radiometer Reference (WRR) irradiance scale and the Electrotechnical Laboratory (ETL) spectral irradiance scale. In addition, we confirm the intercomparison precision using the test facility where the irradiance of ETL 500 W standard lamp can be measured directly with the cavity radiometer. The results showed that the irradiance based on the WRR scale was 0.5-0.7% lower than the one based on the ETL scale
1997-10-14
Development of a real-time, neutron and gamma dosimeter
Energy Technology Data Exchange (ETDEWEB)
In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)
2001-07-01
Development of a real-time, neutron and gamma dosimeter
International Nuclear Information System (INIS)
In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)
2001-06-10
O the Use of Time and Correlation Windows for Non-Parametric Spectral Analysis.
Available from UMI in association with The British Library. Requires signed TDF. Design of time and correlation windows for non -parametric frequency response estimates. The thesis deals with problems that arise in the field of spectral analysis due to finite observations of input and output records. In particular, it is concerned with the method of applying time and correlation windows in spectral analysis procedures to obtain non-parametric frequency response estimates of open-loop time invariant systems. The thesis reviews and develops the sources of error that arise when frequency response techniques are applied directly to windowed records of input and output data to estimate the frequency response of open loop systems. Having identified the cause of these errors, methods of eliminating or reducing them are studied. The techniques introduced involve the use of differing time windows for the input and output data records. It is shown that ...
1990-01-01
Energy Technology Data Exchange (ETDEWEB)
Laboratory studies have been carried out to determine the toxicity of methiocarb pellets to wild trapped wood mice in order to provide some background data prior to any further evaluation of hazard in the field. In this study, wood mice were exposed to dry and to dampened methiocarb pellets in order to reproduce field trial application conditions. Field observations of methiocarb pellets indicate that the physical character changes under dry and wet weather conditions. This may affect their relative attractiveness and potential toxicity to wood mice. The laboratory assessment of exposed wood mice included measurement of brain esterase activities, methiocarb residues in selected mouse tissue, carcasses, and histological evaluation of kidney, liver and lungs.
1988-01-01
Gases in insulating oil - analysis of dissolved gases using a portable chromatograph
Energy Technology Data Exchange (ETDEWEB)
New technological advances make it possible to perform on site gas-in-oil analysis quickly and efficiently. Gas-in-oil analysis is crucial in assessing the status of oil-filled electrical equipment. The new technique is used for extracting and measuring gases dissolved in electrical insulating oil. On-site sampling requires the use of a specially designed 100 ml capacity syringe. Extraction of the dissolved gases is made with a precise ratio of oil to air. A comparison was made between the analysis of the on-site and the laboratory techniques. Results showed that the detection limits of the on-site technique were comparable to those obtained by laboratory methods.
1996-07-01
Electromagnetic coupling of high-altitude, nuclear electromagnetic pulses
International Nuclear Information System (INIS)
We have used scale models to measure the predicted coupling of electromagnetic fields simulating the effects of high-altitude nuclear electromagnetic pulses (HEMP) on the interior surfaces of electronic components. Predictive tools for exterior coupling are adequate. For interior coupling, however, such tools are in their infancy. Our methodological approach combines analytical, computational, and laboratory techniques in a complementary way to take advantage of their separate strengths. Computer models are a promising tool, as they can be used to treat complex objects with arbitrary shapes, dielectrics, and cables, and multiple apertures. Laboratory tests can expand the domain of investigation even further.
1984-11-01
iII1TEImETFlIES - NASA Technical Report Server (NTRS)
The various sources of inertial navigation error are discussed in Section 2.2. It is the nature of inertial navigation errors ...
Utilization of consistency metrics for error analysis in deformable image registration
UK PubMed Central (United Kingdom)
PurposeTo investigate the utility of consistency metrics, such as inverse consistency, in contour based deformable registration error analysis.Full Text Available
2009-09-21
Tightly Integrating Optical And Inertial Sensors For Navigation ...
... 13 2.4 Inertial Navigation Error Model . . . . . ... sources such as electrical noise, thermal noise, etc. 2.4 Inertial Navigation Error Model ...
2008-03-01
Gravity Gradiometer Survey and Real Time Techniques for ...
... 4 II. INERTIAL NAVIGATION ERROR EQUATIONS ..... 5 ... 4- Page 20. Chapter II INERTIAL NAVIGATION ERROR EQUATIONS ...
1981-12-01
Fusion of Imaging and Inertial Sensors for Navigation
... 2.5.6 Development of Observation Equations . . . . . 25 2.6 Inertial Navigation Error Model . . . . . ... 2 , as expected. 2.6 Inertial Navigation Error Model ...
2006-09-01
Error Analysis Strapdown Inertial Navigation Using ...
... Abstract : The purpose of this paper is to introduce strapdown inertial navigation error equations based on a quaternion relation between body-fixed ...
1986-06-01
International Nuclear Information System (INIS)
... 45 p. absorption spectroscopy errors lead lead 203 beta decay radioisotopes
1981-05-01
A Hybrid Integrity Solution for Precision Landing and ...
... HAL and VAL limits with the specified PMD of 10-7, the GPS range-rate error must be monitored to assure that the inertial navigation error is not ...
2004-04-01
Probing dark energy with the shear-ratio geometric test
We adapt the Jain-Taylor (2003) shear-ratio geometric lensing method to measure the dark energy equation of state, w = pv/?v and its time derivative from dark matter haloes in cosmologies with arbitrary spatial curvature. The full shear-ratio covariance matrix is calculated for lensed sources, including the intervening large-scale structure and photometric redshift errors as additional sources of noise, and a maximum likelihood method for applying the test is presented. Decomposing the lensing matter distribution into dark matter haloes we calculate the parameter covariance matrix for an arbitrary experiment. Combining with the expected results from the cosmic microwave background (CMB) we design an optimal survey for probing dark energy. This shows that a targeted survey imaging 60 of the largest clusters in a hemisphere with five-band optical photometric redshifts to a median galaxy depth of zm = 0.9 could measure w0 ? ...
2007-02-01
Synchronous Averaging for Asynchronous Sampling Data
The progress of digital audio technology enabled the familiar use of the products such as CD and DAT in the acoustic measurement. For example, a signal reproduced with CD player is inputted into a subject of measurement and DAT recorder records its response. However, the sampling cannot be synchronized completely with the input signal although both nominal sample rates are set up equally, because player and recorder work independently. It is the most popular software solution to perform the synchronous addition after converting the recorded signal into the original sampling rate. However, the rate conversion also has the error due to the windowing in the high frequency region of processed signal. This paper proposes a new method for averaging asynchronous sampling data to solve these problems. To evaluate performance, the transfer function of only measuring equipment estimated from asynchronous sampling ...
2005-01-01
Moving finite element codes in one and two dimensions. Final report
Energy Technology Data Exchange (ETDEWEB)
Many problems in physics necessitate the solution of equations which develop sharp gradients, such as shocks. These include atmospheric shocks near the earth's surface, plasma physics phenomena, both in the laboratory and in space, combustion, petroleum reservoir modelling, and light propagation in glass fibers. To deal with this situation, methods are needed which place a high density of nodes in the neighborhoods of the steep gradients. One of the most promising of these methods is the moving finite element method which was first invented by Miller. This approach, in which the nodes are moved so as to minimize the residual error, has been used successfully by Gelinas, Doss, and co-workers to study several different one-dimensional problems and shows great promise as well in dealing with two dimensions. A paper describing the one-dimensional results has already been published, and a paper describing the two-dimensional results is in ...
1985-10-01
Energy Technology Data Exchange (ETDEWEB)
To help confirm correct functioning of an epithermal neutron sonde, we measured tightly bonded water content of selected Nevada Test Site (NTS) drill holes. Tuff and alluvium samples were dried overnight at 105/sup 0/C. The samples were then heated for 45 min in a split tube furnace at 700/sup 0/C. The water that came off due to this heating was collected and the amount recorded. The error in this procedure is +- 0.59 wt %. Total water can be calculated for samples from analyses of free and tightly bonded water contents. The maximum error in this calculation is equivalent to the error in determining the more tightly bonded water. Average total water content values have been assigned to geologic units. These values, in weight fraction, are alluvium 0.14 +- .05 and tuff 0.19 +- .04. Further division of the tuff gives values of Rainier Mesa 0.15 +- .01, Paintbrush 0.18 +- .03, Tunnel Beds 0.20 +- .04, and ...
1981-05-01
Synopsis of moisture monitoring by neutron probe in the unsaturated zone at Area G
Energy Technology Data Exchange (ETDEWEB)
Moisture profiles from neutron probe data provide valuable information in site characterization and to supplement ground water monitoring efforts. The neutron probe precision error (reproducibility) is found to be about 0.2 vol% under in situ field conditions where the slope in moisture content with depth is varying slowly. This error is about 2 times larger near moisture spikes (e.g., at the vapor phase notch), due to the sensitivity of the probe response to vertical position errors on the order of 0.5 inches. Calibrations were performed to correct the downhole probe response to the volumetric moisture content determined on core samples. Calibration is sensitive to borehole diameter and casing type, requiring 3 separate calibration relations for the boreholes surveyed here. Power law fits were used for calibration in this study to assure moisture content results greater than zero. Findings in the boreholes reported here ...
1997-12-31
The detection of rare mutations has many important applications, including risk assessment of drugs and chemicals, measuring environmental exposures to genotoxins, and cancer cell detection. A sensitive genotypic selection method has been developed that combines two different mutant allele selection techniques, MutEx enrichment and allele-specific competitive blocker PCR (ACB-PCR). This method was developed and evaluated for the detection of a CAA --> AAA mutation at codon 61 of the mouse H-ras gene. The MutEx enrichment is based on MutS binding to a mismatched basepair in heteroduplex DNA. The bound MutS protects the mutant allele from degradation during subsequent exonuclease treatment. ACB-PCR preferentially amplifies a mutant allele in a PCR reaction using a primer that has more mismatches to the wild-type allele than the mutant allele. By combining these two approaches, the codon 61 mutation was detected at mutant fractions as low as 1 in 10(7). This ...
1998-01-01
Energy Technology Data Exchange (ETDEWEB)
The computer program is developed based on Visual C++, which is equipped with a user-friendly interface of the input/output(I/O) and a display function for the measuring conditions. This program consists of three parts which are the port communication, PLC(Programmable Logic Controller) and the MCA(Multi Channel Analyzer) control parts. The communication type between the CPU of the PLC module box and the computer is selected as be the Rs-232 asynchronous type and the thread method is adapted in the development of the first part of the program. The PLC-related program has been developed so that the data communication between the PLC CPU and the computer could be harmonized with the unique commands which have already been defined in the PLC. The measuring space and time intervals, the start and end ROI(region of interest) values, and the allowable error limitation are input at each measurement in this ...
2005-11-15
Review of Experimental Studies of $\\psi(3770)$ non-$D\\bar D$ Decays
We review the progress on experimental studies of the non-$D\\bar D$ decays of the $\\psi(3770)$ resonance. With the world average of the observed cross sections for $D\\bar D$ production measured at 3.773 GeV by the MARK-I, MARK-II, BES and CLEO Collaborations, combined together with the cross section for $\\psi(3770)$ production at its peak as well as initial state radiative correction factor, we find that the non-$D\\bar D$ branching fraction of $\\psi(3770)$ decays is $B[\\psi(3770)\\to {\\rm non}-D\\bar D]=(19.8\\pm 1.8 \\pm 5.6)%$, which is consistent within error with $B[\\psi(3770)\\to {\\rm non}-D\\bar D]=(14.7\\pm 3.2)%$ measured previously by the BES Collaboration. In addition, a global amplitude analysis of the cross sections for $e^+e^- \\to {\\rm LH}$ (LH= light hadron) measured by the CLEO Collaboration shows that the light hadron branching fraction of $\\psi(3770)$ decays can be as large ...
2010-01-01
Proton G{sub E}/G{sub M} from beam-target asymmetry
The ratio of the proton's electric to magnetic form factor, G{sub E}/G{sub M}, can be extracted in elastic electron-proton scattering by measuring cross sections, beam-target asymmetry, or recoil polarization. Separate determinations of G{sub E}/G{sub M} by cross sections and recoil polarization observables disagree for Q{sup 2}>1 (GeV/c){sup 2}. Measurement by a third technique might uncover an unknown systematic error in either of the previous measurements. The beam-target asymmetry has been measured for elastic electron-proton scattering at Q{sup 2} = 1.51 (GeV/c){sup 2} for target spin orientation aligned perpendicular to the beam momentum direction. This is the largest Q{sup 2} at which G{sub E}/G{sub M} has been determined by a beam-target asymmetry experiment. The result, {mu}G{sub E}/G{sub M}=0.884{+-}0.027{+-}0.029, is compared to previous world data.
2006-09-15
Measurement of redshifted 21-cm emission from neutral hydrogen promises to be the most effective method for studying the reionisation history of hydrogen and, indirectly, the first galaxies. These studies will be limited not by raw sensitivity to the signal, but rather, by bright foreground radiation from Galactic and extragalactic radio sources and the Galactic continuum. In addition, leakage due to gain errors and non-ideal feeds conspire to further contaminate low-frequency radio obsevations. This leakage leads to a portion of the complex linear polarisation signal finding its way into Stokes I, and inhibits the detection of the non-polarised cosmological signal from the epoch of reionisation. In this work, we show that rotation measure synthesis can be used to recover the signature of cosmic hydrogen reionisation in the presence of contamination by polarised foregrounds. To achieve this, we apply the rotation ...
2010-01-01
Modification of SGS system for application to various sized drums
Energy Technology Data Exchange (ETDEWEB)
To dispose the radioactive waste drums, the waste form's integrity and the nuclides inventories must be assured according to the national and site waste acceptance criteria. Because they might be would gravely affected the performance objectives of disposal site. Our national regulation for the waste inventory related to 'Radioactive Waste Acceptance Criteria' requires that the activities of 13 nuclides and gross {alpha} must be measured and the 95 % of nuclides incorporated in the drum must be identified. It is very difficult to measure the radioactivity with accuracy from the regulated waste drum(200L), and have a large error in the analysis results. In present, there are two system, SGS (Segmented Gamma Scanning System) and TGS (Tomographic Gamma Scanning System) for the analysis of radionuclides from the waste drums. In general, it is known that the accuracy of TGS is below 20 % and that of ...
2005-11-15
Modification of SGS system for application to various sized drums
International Nuclear Information System (INIS)
To dispose the radioactive waste drums, the waste form's integrity and the nuclides inventories must be assured according to the national and site waste acceptance criteria. Because they might be would gravely affected the performance objectives of disposal site. Our national regulation for the waste inventory related to 'Radioactive Waste Acceptance Criteria' requires that the activities of 13 nuclides and gross #alpha# must be measured and the 95 % of nuclides incorporated in the drum must be identified. It is very difficult to measure the radioactivity with accuracy from the regulated waste drum(200L), and have a large error in the analysis results. In present, there are two system, SGS (Segmented Gamma Scanning System) and TGS (Tomographic Gamma Scanning System) for the analysis of radionuclides from the waste drums. In general, it is known that the accuracy of TGS is below 20 % and that of SGS is below 30 %. The ...
2005-11-01
Los Alamos second-generation system for passive and active neutron assays of drum-size containers
International Nuclear Information System (INIS)
We describe in a comprehensive fashion the Los Alamos second-generation system for passive and active neutron assays of drum-size containers. The developmental history of this 7-year project is presented with emphasis on the pulsed active neutron technique (differential dieaway), which has achieved milligram levels of assay sensitivity for both plutonium and uranium wastes. We describe in detail the matrix effects for both passive and active neutron assays. We present in a thorough fashion our novel approach to achieving comprehensive corrections for these matrix effects using measurements made during the assays. We develop a matrix correction formalism based on separate neutron absorption and moderator indices determined from these measurements. These are presented as a series of analytic functions fitted to the data. Absolute calibrations and calibration standards are discussed, as is a practical means (pink drum ...
1972-09-17
Development of production methods of volume source by the resinous solution which has hardening
Volume sources is used for standard sources by radioactive measurement using Ge semiconductor detector of environmental sample, e.g. water, soil and etc. that require large volume. The commercial volume source used in measurement of the water sample is made of agar-agar, and that used in measurement of the soil sample is made of alumina powder. When the plastic receptacles of this two kinds of volume sources were damaged, the leakage contents cause contamination. Moreover, if hermetically sealing performance of volume source made of agar-agar fell, volume decrease due to an evaporation off moisture gives an error to radioactive measurement. Therefore, we developed the two type methods using unsaturated polyester resin, vinilester resin, their hardening agent and acrylicresin. The first type is due to dispersing the hydrochloric acid solution included the radioisotopes uniformly in ...
2002-01-01
Burnup determination of spent nuclear fuel in the pool
Energy Technology Data Exchange (ETDEWEB)
A algorithm was developed to determine the characteristic parameters of PWR spent fuel, such as burnup, cooling time and initial enrichment of {sup 235}U by use of gamma-ray activity ratios of {sup 134}Cs/{sup 137}Cs, {sup 154}Eu/{sup 137}Cs and {sup 106}Ru/{sup 137}Cs from the high resolution gamma-ray spectroscopy and ORIGEN-S calculations. For the verification of the method developed, gamma-ray measurements of Kori-1 and Kori-2 nuclear fuel rods were carried out using HPGe gamma ray scanning system. As a results, it is revealed that the measured values are in a good agreement with the operator declared values within the about {+-} 5% errors. Besides, the under-water burnup measuring device has been designed to measure the gamma-ray from the PWR spent fuel assembly. This device will be set up in the pool of Post-Irradiation Examination Facility(PIEF), and used in determination of ...
1998-06-01
International Nuclear Information System (INIS)
A method of the correction for sample self attenuation used in segmented gamma scanner (SGS) is described. The method of calibration for assaying the uranium and plutonium contents of each category of heterogeneous process residues and wastes in nuclear facilities is studied. The effect of variable measurement parameter on measurement results is also studied. The measurement results of SGS assay is compared with that of the destructive assay (DA), which is aimed at evaluating SGS method for assaying uranium and plutonium content in process residues and wastes. The deviation of two assay results is 3.6%. The SGS assay results and DA assay results both are coincided well in error limits. Four category of heterogeneous process residues and wastes in nuclear facilities have assayed successfully in physical inventory. The uncertainty of measurement results for uranium and plutonium ...
1998-09-01
Use of portable HPGE detector and multichannel analyzer for in-situ gamma spectrometry of soil
International Nuclear Information System (INIS)
Measurement of fission and activation products in the soil or over a plane grass land of a nuclear power station environment is required to find out the long term changes. The inventory of radionuclides in the soil is routinely determined by soil sampling, processing and gamma spectrometry in the laboratory. The method although is proven and accurate is time consuming and largely dependent on homogenous distribution. Therefore, an alternative and rapid method of in-situ gamma spectrometry using portable devices was standardized to determine the concentration of radionuclides in soil, for regular environmental monitoring as well as during emergency condition. The paper presents the methodology, ready to use factors and compares the results of a few measurements made in the environment of Tarapur Atomic Power Station by both in-situ and laboratory methods. (author)
2005-11-23
Sample requirements and design of an inter-laboratory trial for radiocarbon laboratories
International Nuclear Information System (INIS)
An on-going inter-comparison programme which is focused on assessing and establishing consensus protocols to be applied in the identification, selection and sub-sampling of materials for subsequent "1"4C analysis is described. The outcome of the programme will provide a detailed quantification of the uncertainties associated with "1"4C measurements including the issues of accuracy and precision. Such projects have become recognised as a fundamental aspect of continuing laboratory quality assurance schemes, providing a mechanism for the harmonisation of measurements and for demonstrating the traceability of results. The design of this study and its rationale are described. In summary, a suite of core samples has been defined which will be made available to both AMS and radiometric laboratories. These core materials are representative of routinely dated material and their ages span the full range of the ...
2000-10-01
Energy Technology Data Exchange (ETDEWEB)
Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is ...
2010-10-15
International Nuclear Information System (INIS)
Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is ...
2010-10-01
Energy Technology Data Exchange (ETDEWEB)
A laboratory differential simulation method is used for the design of carbonization columns at coal-tar processing in which phenols are regenerated from phenolate solution by carbon dioxide absorption. The design method is based on integration of local absorption rates of carbon dioxide along the column. The local absorption rates into industrial phenolate mixture are measured in a laboratory model contactor for various compositions of the gas and liquid phases under the conditions that ensure the absorption rates in the laboratory absorber simulate the local rates in the industrial column. On the bases of the calculations, two-step carbonization columns were designed for 30000 t/year of the phenolate solution treatment by carbon dioxide. The absorption proceeds at higher pressure of 500 kPa and temperatures from 50 to 65 C, pure carbon dioxide is used and toluene is added. These conditions have the ...
2009-01-15
International Nuclear Information System (INIS)
These summary descriptive data of ethnically similar cohorts of indigenous and migrant Japanese males have shown similarities or slight differences in characteristics wholly or largely genetically determined, such as blood groups, stature, and skeletal size. Differences have been noted in characteristics largely environmental or behavioral, such as diet and cigarette smoking habit, as well as in characteristics determined by a varying mixture of genetic and environmental influences, such as weight, blood pressure, glucose tolerance, and serum lipid and uric acid levels. Detailed analyses of the distributions of laboratory variables, of dietary data obtained by different methods, and of correlations among laboratory, dietary, physical, and demographic variables are currently in progress. Also part of the study plan are determinations of disease prevalence from evaluation of examination, laboratory, and electrocardiographic ...
International Nuclear Information System (INIS)
Molar excess enthalpies and molar excess volumes are reported for the systems H_2O + (C_2H_5)_3N and D_2O + (C_2H_5)_3N at temperatures below and above their lower critical solution temperatures. The molar excess enthalpies are slightly less exothermic for the D_2O system. The molar excess volumes of the H_2O and D_2O systems are within experimental error of one another. Compositions of conjugate solutions estimated from the calorimetric and volumetric measurements agree with those obtained from published liquid-liquid phase diagrams. (Auth.).
1979-01-01
British Library Electronic Table of Contents (United Kingdom)
A large database (507 station-years) of daily suspended particulate matter (SPM) concentration and discharge data from 36 stations on river basins ranging from 600?km2 to 600,000?km2 in size (USA and Europe) was collected to assess the effects of SPM transport regime on bias and imprecision of flux estimates when using infrequent surveys and the discharge-weighted mean concentration method. By extracting individual SPM concentrations and corresponding discharge values from the database, sampling frequencies from 12 to 200 per year were simulated using Monte Carlo techniques. The resulting estimates of yearly SPM fluxes were compared to reference fluxes derived from the complete database. For each station and given frequency, bias was measured by the median of relative errors between estima...
2006-01-01
Precise Determination of the Neutron Magnetic Form Factor to Higher Q{sup 2}
Energy Technology Data Exchange (ETDEWEB)
The neutron elastic magnetic form factor G{sub M}{sup n} has been extracted from quasielastic scattering from deuterium in the CEBAF Large Acceptance Spectrometer, CLAS [B. Mecking et al., Nucl. Inst. and Meth. A 503 (2003) 513]. The kinematic coverage of the measurement is continuous over a broad range, extending from below 1 GeV{sup 2} to nearly 5 GeV{sup 2} in four-momentum transfer squared. High precision is achieved by employing a ratio technique in which most uncertainties cancel, and by a simultaneous in-situ calibration of the neutron detection efficiency, the largest correction to the data. Preliminary results are shown with statistical errors only.
2005-06-13
Precise Determination of the Neutron Magnetic Form Factor to Higher Q"2
International Nuclear Information System (INIS)
The neutron elastic magnetic form factor G_M"n has been extracted from quasielastic scattering from deuterium in the CEBAF Large Acceptance Spectrometer, CLAS [B. Mecking et al., Nucl. Inst. and Meth. A 503 (2003) 513]. The kinematic coverage of the measurement is continuous over a broad range, extending from below 1 GeV"2 to nearly 5 GeV"2 in four-momentum transfer squared. High precision is achieved by employing a ratio technique in which most uncertainties cancel, and by a simultaneous in-situ calibration of the neutron detection efficiency, the largest correction to the data. Preliminary results are shown with statistical errors only.
2005-06-13
Energy Technology Data Exchange (ETDEWEB)
Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic scattering is estimated to be extremely weak and higher S/N of {approx}10{sup 4} or more is required to detect the magnetic scattering ...
2009-02-21
International Nuclear Information System (INIS)
Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic scattering is estimated to be extremely weak and higher S/N of ?104 or more is required to detect the magnetic scattering of this ...
2009-02-21
British Library Electronic Table of Contents (United Kingdom)
This paper presents a dynamic displacement influence line method for moving load identification on bridge. The finite element model of Poyang Lake continuous truss bridge-train systems is established and the dispersed modal shapes are acquired by modal analysis. Multi-axle moving train loads are identified with simulated annealing genetic algorithm by minimizing the errors between the measured displacements and the reconstructed displacements from the identified moving loads. In the identification process, the dynamic displacement influence line technique is used to calculate the time history displacement responses of the bridge to avoid solving equations of motion of the bridge repetitively. Several important parameters of the bridge-train system are discussed to investigate their effects...
2011-01-01
International Nuclear Information System (INIS)
In this work the calculation of the average precipitation in the Quito River basin, state of Choco, Colombia, is presents through diverse techniques, among which are those suggested by Thiessen and those based on the isohyets analysis, in order to select the one appropriate to quantification of rainwater available to the basin. Also included is an estimation of the error with which the average precipitation in the zone studied is fraught when measured, by means of the methodology proposed by Gandin (1970) and Kagan (WMO, 1966), which at the same time allows to evaluate the representativeness of each one of the stations that make up the rain gauge network in the area. The study concludes with a calculation of the hydrologic balance for the Quito river basin based on the pilot procedure suggested in the UNESCO publication on the study of the South America hydrologic balance, from which the great contribution of rainfall to a greatly enhanced ...
2006-03-01
Lessons learned from accidents in industrial radiography
International Nuclear Information System (INIS)
Industrial radiography accounts for approximately half of all the reported accidents for the nuclear related industry, in both developed and developing countries. This Safety Report is the result of a review made of a large selection of accidents in industrial radiography reported by regulatory authorities, professional associations and scientific journals. A small, representative selection of 43 accident descriptions has been used to illustrate the primary causes of radiography accidents, and a set of measures provided to prevent the recurrence of such accidents or to mitigate the consequences of those that do occur. These accident descriptions were categorized by primary causes as follows: inadequate regulatory control; failure to follow operational procedures; inadequate training; inadequate maintenance; human error; equipment malfunction or defect; design flaws; and wilful violation. The information in this Safety report is intended for use ...
Fundamental limits on beam stability at the advanced photon source
International Nuclear Information System (INIS)
Orbit correction is now routinely performed at the few-micron level in the Advanced Photon Source (APS) storage ring. Three diagnostics are presently in use to measure and control both AC and DC orbit motions: broad-band turn-by-turn rf beam position monitors (BPMs), narrow-band switched heterodyne receivers, and photoemission-style x-ray beam position monitors. Each type of diagnostic has its own set of systematic error effects that place limits on the ultimate pointing stability of x-ray beams supplied to users at the APS. Limiting sources of beam motion at present are magnet power supply noise, girder vibration, and thermal timescale vacuum chamber and girder motion. This paper will investigate the present limitations on orbit correction, and will delve into the upgrades necessary to achieve true sub-micron beam stability.
1998-12-10
Evaluation of a temperature model of the continuous steel casting process
Energy Technology Data Exchange (ETDEWEB)
This report summarizes some experiences gathered when using the semi-empirical temperature model that forms the heart of the steel casting advisory system `TUNDTEMP` in simulating the casting process. The model estimates the evolution of the liquid steel temperature in a tundish of a continuous casting machine through a temperature prediction at a couple of central time instants during the casting process. The results are compared with corresponding actual observations during the castings - measured steel temperatures and recorded casting difficulties and interruptions. Explanations for the possible discrepancies are suggested. Starting from a heuristically chosen set of model parameter values, some developing steps have been tested to reduce the simulation errors. The study concentrates mainly on temperature predictions for single heat castings. At the end of the report, some simulations of sequence castings are also briefly discussed
1993-11-01
Effect of mass transport on the determination of corrosion rates from polarization measurements
Energy Technology Data Exchange (ETDEWEB)
Many methods have been proposed for the determination of the corrosion current density from polarization curves; the two most commonly used ones are the three-point method and the curve-fitting method. The basis of these methods is a polarization equation that was derived for the complete absence of mass-transport effect or considers the cathodic partial reaction to be under complete mass-transport control. The mixed-control case has been much less investigated, even though this case may quite frequently reflect practical situations. A completely generalized polarization equation is proposed that can be used as a basis for curve-fitting data evaluation under any conditions. This equation was used to determine the error caused by the neglect of mass-transport effect in conventional data evaluation.
1986-10-01
Double peak effect in microdosimetric proportional counters and its interpretation
Energy Technology Data Exchange (ETDEWEB)
In calibration measurements with low energy X-rays, a double peak effect appears in low pressure proportional counters with a helix, when used for simulation of tissue equivalent diameters considerably larger than 2 m. An interpretation of this phenomenon is discussed, based upon electron capture and electric field perturbation at the counter helix. A description of the physical processes is presented showing that the double peak effect is a problem in the case of helix counters (called also Rossi counters) for all simulated diameters. Conclusions are drawn on systematic errors introduced by the counter helix into microdosimetric spectra and anti y/sub D/ of photons and neutrons. The authors recommend to use cylindrical counters with optimized geometrical and electronic parameters rather than the spherical counters with a helix discussed.
1989-01-01
Development of thick layer re-wetting model for brown rice packaged with LDPE and PBT films
British Library Electronic Table of Contents (United Kingdom)
A mathematical model was developed to predict a moisture content profile during the thick layer re-wetting process of brown rice unpackaged and packaged with low density polyethylene (LDPE) and polybutylene terephthalate (PBT) films. Model validation was carried out by comparing predicted with measured moisture content derived from relative humidity data obtained from the brown rice re-wetting test for 6days at 25degreeC and 90% RH. The moisture standard errors of the model validation for brown rice packaged in LDPE and PBT films were 0.08% wet basis (wb) and 0.11%wb, respectively. It was concluded that the proposed re-wetting model could successfully describe the thick layer re-wetting of brown rice under the experimental conditions. Using this model, re-wetting simulations were carried o...
2010-01-01
Recently, applying the novel data mining techniques for evaluating enterprise financial distress has received much research alternation. Support Vector Machine (SVM) and back propagation neural (BPN) network has been applied successfully in many areas with excellent generalization results, such as rule extraction, classification and evaluation. In this paper, a model based on SVM with Gaussian RBF kernel is proposed here for enterprise financial distress evaluation. BPN network is considered one of the simplest and are most general methods used for supervised training of multilayered neural network. The comparative results show that through the difference between the performance measures is marginal; SVM gives higher precision and lower error rates.
2010-01-01
Analysis of photon beam exit dose using photon point kernels
International Nuclear Information System (INIS)
The Monte Carlo method is used to analyse the dose fall-off at the exit surface of a megavoltage photon beam. The convolution/superposition method of dose calculation using Monte-Carlo-generated homogeneous photon kernels is shown to be in error for exit dose calculation. Instead, photon kernels that incorporate modelling of the exit surface were generated, also using Monte Carlo, to analyse the problem, and the calculated dose fall-off using these kernels agrees well with measured data. In addition, the physics underlying the characteristics of the dose fall-off is analysed based on complete Monte Carlo modelling. Practical improvements to the convolution/superposition method are suggested. (Author).
Radwaste Drum Assay Technology by Segmented Gamma Scanning System
Energy Technology Data Exchange (ETDEWEB)
Nuclear Act of Korea requires the manifest of low and intermediate level radioactive waste generated from nuclear power plants and other nuclear facilities prior to deliver to a disposal sites. Individual history records of the radioactive waste should be described the information about the activity of nuclides in the drum, total activity, weight, the type of waste. So a fully automated nuclide analysis assay system(non-destructive) of a radwaste drum was developed. For the nuclides that could not be analysed directly by MCA, the activities of the representative {gamma}-emitters(Cs-137, Co-60) contained in the drum were measured by using that system. Then the scaling factors were used to calculate the activities of {alpha} - and {beta}-emitters. This assay system divided a drum into 8 segments, a segment into 8 sectors to minimize analysis error, and used several methods(transmission ratio, differential peak absorption, mean density ...
2009-01-15
University of Central Lancashire - Facilities
...specialised laboratories for pharmaceutics, tissue culture and molecular biology Excellent Laboratory Facilities Tissue Culture Facilities Molecular Biology Laboratory ...
Energy Technology Data Exchange (ETDEWEB)
The performance of a group of reference laboratories measuring lead in blood, has been monitored by an intensive external quality assessment programme, since 1974. Performance was similar to that observed in other, larger quality control surveys but rapidly improved following detailed investigations of critical factors in the analytical methodology. The introduction of a rigorous internal quality control protocol, with all laboratories using the same well-characterised materials, has produced external quality control results that are both accurate and very tightly distributed. Between-laboratory coefficients of variation of less than 5%, less than 6% and less than 20% are now obtained at concentrations of over 1.0 ..mu..mol/l (20.7 ..mu..g/dl), 0.5-1.0 ..mu..mol/l (10-20 ..mu..g/dl) and less than 0.5 ..mu..mol/l (10 ..mu..g/dl), respectively. These results represent the best that can be achieved by ...
1988-12-01
APMP/TCRI key comparison report of measurement of air kerma for medium-energy x-rays (APMP.RI(I)-K3)
Energy Technology Data Exchange (ETDEWEB)
The APMP/TCRI Dosimetry Working Group performed the APMP.RI(I)-K3 key comparison of measurement of air kerma for medium-energy x-rays (100 kV to 250 kV) between 2000 and 2003. In total, 11 institutes took part in the comparison, among which 8 were APMP member laboratories. Two commercial cavity ionization chambers were used as transfer instruments and circulated among the participants. All the participants established the 100 kV, 135 kV, 180 kV and 250 kV x-ray beam qualities equivalent to those of the BIPM. The results showed that the maximum difference between the participants and the BIPM in the medium-energy x-ray range, evaluated using the comparison data of the linking laboratories ARPANSA and PTB, is less than 1.4%. The degrees of equivalence between the participants are presented and this comparison confirms the calibration capabilities of the participating laboratories. (authors)
2008-10-15
Technical note: A physical phantom for assessment of accuracy of deformable alignment algorithms
International Nuclear Information System (INIS)
The purpose of this study was to investigate the feasibility of a simple deformable phantom as a QA tool for testing and validation of deformable image registration algorithms. A diagnostic thoracic imaging phantom with a deformable foam insert was used in this study. Small plastic markers were distributed through the foam to create a lattice with a measurable deformation as the ground truth data for all comparisons. The foam was compressed in the superior-inferior direction using a one-dimensional drive stage pushing a flat 'diaphragm' to create deformations similar to those from inhale and exhale states. Images were acquired at different compressions of the foam and the location of every marker was manually identified on each image volume to establish a known deformation field with a known accuracy. The markers were removed digitally from corresponding images prior to registration. Different image registration algorithms were tested using this method. Repeat ...
2007-07-01
Models of continuous-variable quantum computing
Energy Technology Data Exchange (ETDEWEB)
We discuss strictly efficient models for measurement-based quantum computing using physical continuous variables, such as field modes of light. Such measurement-based quantum computing (MBQC) provides a promising paradigm for quantum computation as it does not require performing unitary gates during the computation, but rather appropriate readout. Here, we introduce novel schemes for which the resource state can be reasonably and efficiently prepared, and which notably do not require having infinite squeezing or mean energy available. What is more, error correction techniques are implementable, as the logical information is stored in finite-dimensional objects grasping correlations of the quantum states. Using the ideas of computational tensor networks we discuss how to sequentially prepare suitable physical resource states with cavity QED or with non-linear optics and how to efficiently implement a computational universal ...
2009-07-01
Energy Technology Data Exchange (ETDEWEB)
Two types of switched electrode electronics beam position monitors are in use at Jefferson Lab. Together they provide accurate beam position to the control system for beam intensities between 50 nA and 2 mA. One version, called the linac style, has a switching frequency of 125 kHz. The other, called the transport type, has a switching frequency of 7 kHz. The basic system provides information to the control system at a 1 Hz update rate. The systems are regularly used to measure the AC component of beam position and energy as well as suppress this motion as part of a fast feedback system. Position data produced by the system are also acquired on an event by event basis as part of the nuclear physics program in two of the experimental halls. This paper will focus on the AC characteristics of the system. These characteristics are affected by analog filter frequencies and a time delay between the measurement of the positive electrode signal and the ...
2000-05-01
Direct observation of ordered orbital of YTiO_3 by the X-ray magnetic diffraction technique
International Nuclear Information System (INIS)
X-ray magnetic diffraction (XMD) technique was applied to an orbital ordering compound of ferromagnetic YTiO_3 for the first time. The orbital-magnetic form factor #mu# _L(k) and the spin-magnetic form factor #mu# _S(k) were independently measured by utilizing the LS separation ability of the XMD. The #mu# _L(k) was measured for ten reciprocal-lattice points. No significant values of the #mu# _L(k) were observed for most of the reciprocal-lattice points within the estimated statistical errors, which suggested quenching of the orbital moment. The #mu# _S(k) was measured for 22 reciprocal-lattice points. Fourier synthesis of the #mu# _S(k) gave the spin density distribution m _S(r) in the real space. The obtained m _S(r) map shows the characteristic feature of the electron distribution of 3d electron in the t_2_g state of a Ti atom coordinated by O"2"- ions, in which the electrons are distributed away ...
2005-08-01
Constraining the Dark Energy Equation of State using Alternative High-z Cosmic Tracers
We propose to use alternative cosmic tracers to measure the dark energy equation of state and the matter content of the Universe [w(z) & Omega_m]. Our proposed method consists of two components: (a) tracing the Hubble relation using HII galaxies which can be detected up to very large redshifts, z~4, as an alternative to supernovae type Ia, and (b) measuring the clustering pattern of X-ray selected AGN at a median redshift of z~1. Each component of the method can in itself provide interesting constraints on the cosmological parameters, especially under our anticipation that we will reduce the corresponding random and systematic errors significantly. However, by joining their likelihood functions we will be able to put stringent cosmological constraints and break the known degeneracies between the dark energy equation of state (whether it is constant or variable) and the matter content of the universe and provide a ...
2009-01-01
Alternative High-z Cosmic Tracers and the Dark Energy Equation of State
We propose to use alternative cosmic tracers to measure the dark energy equation of state and the matter content of the Universe [w(z) & \\Omega_m]. Our proposed method consists of two components: (a) tracing the Hubble relation using HII-like starburst galaxies, as an alternative to SNIa, which can be detected up to very large redshifts, z~4, and (b) measuring the clustering pattern of X-ray selected AGN at a median redshift of ~1. Each component of the method can in itself provide interesting constraints on the cosmological parameters, especially under our anticipation that we will reduce the corresponding random and systematic errors significantly. However, by joining their likelihood functions we will be able to put stringent cosmological constraints and break the known degeneracies between the dark energy equation of state (whether it is constant or variable) and the matter content of the universe and provide a ...
2009-01-01
Top physics at the Tevatron Collider
Energy Technology Data Exchange (ETDEWEB)
The top quark has been discovered in 1995 at the CDF and DO experiments located in the Tevatron ring at the Fermilab laboratory. After more than a decade the Tevatron collider, with its center-of-mass energy collisions of 1.96 TeV, is still the only machine capable of producing such exceptionally heavy particle. Here I present a selection of the most recent CDF and DO measurements performed analyzing {approx} 1 fb{sup -1} of integrated luminosity.
2007-10-01
The proton microprobe: Applications in the biomedical field
Energy Technology Data Exchange (ETDEWEB)
This book explores the development, present, and future applications of proton microprobes in the micrometer range. Among the topics discussed: the use of proton beams for analytical purposes; techniques of focusing or collimating ion beams; improving and measuring beam spots; the analytical capabilities of the nuclear microprobe in comparison to other micro techniques; and applications and results by several internationally known microprobe laboratories.
1986-01-01
Real time neutron diffraction experiments using Bragg edges
Energy Technology Data Exchange (ETDEWEB)
Time resolved phase transition and strain experiments have been performed on the millisecond time scale using a Bragg-edge transmission technique that has been developed at the Los Alamos National Laboratory. The precision with which lattice parameters can be determined from edge positions is sufficient to perform high-resolution strain measurements in uniaxial stress.
1995-12-31
Real time neutron diffraction experiments using Bragg edges
International Nuclear Information System (INIS)
Time resolved phase transition and strain experiments have been performed on the millisecond time scale using a Bragg-edge transmission technique that has been developed at the Los Alamos National Laboratory. The precision with which lattice parameters can be determined from edge positions is sufficient to perform high-resolution strain measurements in uniaxial stress.
1994-12-02
Performance estimates for attached-sunspace passive solar heated buildings
Energy Technology Data Exchange (ETDEWEB)
Performance predictions have been made for attached-sunspace types of passively solar heated buildings. The predictions are based on hour-by-hour computer simulations using computer models developed in the framework of PASOLE, the Los Alamos Scientific Laboratory (LASL) passive solar energy simulation program. The models have been validated by detailed comparison with actual hourly temperature measurements taken in attached-sunspace test rooms at LASL.
1980-01-01
Off-line and on-line-monitoring of power transformers using the transfer function method
Energy Technology Data Exchange (ETDEWEB)
The transfer function concept is well known as an additional method to evaluate the impulse test of power transformers in the test laboratory. Another application for the transfer function method is monitoring of transformers in service. Thereby, Off-line and On-line monitoring can be realized. Both kinds of monitoring are demonstrated with on-site measurements on a power transformer in service.
1996-12-31
Final Report: Planetary Instrument Definition and Design Program (PIDDP) Support Project
Energy Technology Data Exchange (ETDEWEB)
The results of Sandia National Laboratories' participation in the NASA Planetary Definition and Design Program are summarized. Areas reported include the characterization of large area cadmium zinc telluride spectrometers and the application of simulation techniques to the prediction of device performance. Also investigated was the response of mercuric iodide devices in the region from 1 to 100 KeV. A literature study to determine the status or radiation damage measurements in room temperature semiconductor devices is also reported.
1999-03-01
Experimental Verification of the Hall Effect during Magnetic Reconnection in a Laboratory Plasma
Energy Technology Data Exchange (ETDEWEB)
In this letter we report a clear and unambiguous observation of the out-of-plane quadrupole magnetic field suggested by numerical simulations in the reconnecting current sheet in the Magnetic Reconnection Experiment (MRX). Measurements show that the Hall effect is large in collisionless regime and becomes small as the collisionality increases, indicating that the Hall effect plays an important role in collisionless reconnection.
2005-06-16
Dispersant Effectiveness Of Heavy Fuel Oils Using The Baffled Flask Test
Dispersants have been widely used as a primary response measure for marine oil spills around the world. Recently, the U.S. Environmental Protection Agency (EPA) developed an improved laboratory dispersant testing protocol, called the Baffled Flask Test (BFT). The BFT protocol w...
Cumulative kaon production by 10 GeV protons
International Nuclear Information System (INIS)
The K"+- and K"-meson cumulative production cross sections are measured at 119"0 in the laboratory system on nuclei Be, Al, Cu and Ta bombarded by 10 GeV protons. Spectra of the K"-mesons consisting of only sea quarks show universal features characteristic of the spectra of cumulative particles, which contain valence quarks. Evidence is obtained for the fact that the energy density in a flucton can exceed the mean nuclear density by an order of magnitude.
Energy Technology Data Exchange (ETDEWEB)
Low power wire activations are being performed in the Oak Ridge Research Reactor (ORR) as part of the whole-core LEU demonstration experiments. Calculations of the demonstration cores, including simulation of the wire activations, are being performed at Argonne National Laboratory (ANL). This paper presents the results of comparisons for 293 wires from five cores and shows that, on the average, the integrated activities agree within 6%.
1986-01-01
Comment on 'Magnetic braking revisited: activities for the undergraduate laboratory'
International Nuclear Information System (INIS)
Here, we consider a recent paper concerned with magnetic braking by induced currents (Ireson and Twidle 2008 Eur. J. Phys. 29 745-51). Our objective is to elucidate why measurement of speed in which a magnet is dropped through a non-ferromagnetic conductive tube depends on its geometry in a non-monotonic way, which was not clearly explained by the authors. (letters and comments)
2009-03-01
Automated remote positioning and examination of FFTF reactor power characterization dosimeters
Energy Technology Data Exchange (ETDEWEB)
The Fast Flux Test Facility (FFTF) reactor characterization by the Hanford Engineering Development Laboratory (HEDL) includes extensive neutronic measurements during startup and initial operation. To aid in the handling and counting of the thousands of passive dosimeters used as part of this effort, an automated dosimetry specimen handling, positioning, and counting system was designed and developed by Westinghouse Hanford for the Department of Energy.
1981-05-04
Analytical peak fitting for gamma-ray spectrum analysis with Ge detectors
Energy Technology Data Exchange (ETDEWEB)
A comparison of maximum likelihood (or chi-square) and Bayesian peak fitting techniques shows that the latter can reduce peak intensity uncertainties by a factor of up to ten in the case of closely separated doublets, leading to greatly improved doublet resolution. The need for laboratories to demonstrate the reliability of their chosen peak fitting techniques and measures of peak intensity is also demonstrated. (orig.)
1993-10-01
Analytical peak fitting for gamma-ray spectrum analysis with Ge detectors
International Nuclear Information System (INIS)
A comparison of maximum likelihood (or chi-square) and Bayesian peak fitting techniques shows that the latter can reduce peak intensity uncertainties by a factor of up to ten in the case of closely separated doublets, leading to greatly improved doublet resolution. The need for laboratories to demonstrate the reliability of their chosen peak fitting techniques and measures of peak intensity is also demonstrated. (orig.).
An instrument for measuring spatial and time characteristics of sea agitation in coastal zones
Energy Technology Data Exchange (ETDEWEB)
Resistive analogous meters for spatial and time characteristics in ocean agitation are most often used in practical oceanography in coastal zones but are based on bridge circuits determined to have shortcomings in their linearity range. This shortcoming is eliminated in the circuit of an instrument developed in an oceanographic laboratory (IMIO, Vana). Principle and block circuits are indicated, and static calibration curves are presented as are the correlative functions in the frequency spectrums obtained with the help of sea agitation recorded at a fixed point and at a depth of 6 meters.
1981-01-01
Proposed subcritical measurements for fresh and spent highly enriched plate type fuel assemblies
Energy Technology Data Exchange (ETDEWEB)
A collaborative experimental research program has been established between industry and university partners to evaluate the subcritical behavior of fresh and spent highly enriched fuel assemblies at the University of Missouri Research Reactor (MURR). This proposed program will involve a series of subcritical measurements using the Oak Ridge National Laboratory (ORNL) developed {sup 252}Cf source-driven noise technique. Measurements evaluating the subcritical behavior of simple arrays of fresh MURR assemblies will be performed for evaluating the spectral effects of materials typically found in shipping casks such as lead, steel, aluminum, and boron. Also, measurements will be performed on spent assemblies to characterize physics parameters which may be useful in determining the subcritical behavior of fuels for reactivity credit of actinide burnup and fission product poisoning.
1997-09-01
High-precision Absolute Distance and Vibration Measurement using Frequency Scanned Interferometry
In this paper, we report high-precision absolute distance and vibration measurements performed simultaneously with frequency scanned interferometry using a pair of single mode optical fibers. Absolute distance was determined by counting the interference fringes produced while scanning the laser frequency. A high-finesse Fabry-Perot interferometer(F-P) was used to determine frequency changes during scanning. Two multi-distance-measurement analysis techniques were developed to improve distance precision and to extract the amplitude and frequency of vibrations. Under laboratory conditions, a precision of 40 nm was demonstrated for an absolute distance of approximately 0.45 meters using the first analysis technique. The second analysis technique has capability to measure vibration frequencies ranging from 0.1 Hz to 100 Hz with minimal amplitude on few nanometers order without a priori knowledge.
2004-01-01
Development of in-vessel reflood instrumentation at ORNL
International Nuclear Information System (INIS)
A program under the sponsorship of the United States Nuclear Regulatory Commission was intiated at the Oak Ridge National Laboratory (ORNL) in late 1977. The program, Advanced Instrumentation for Reflood Studies (AIRS), is charged with developing instrumentation for measurement of in-vessel fluid phenomena in pressurized water reactor reflood facilities. The goal of the ORNL program is to develop techniques and systems for measuring fluid flow in-core, deentrainment in the upper plenum and liquid fallback from the upper plenum into the core. A large portion of the development at ORNL is devoted to the impedance probes for measurement of two-phase flow velocities and void fractions. Film probe development at ORNL is limited to adapting the present techniques to the environment of a reflood facility. As the development progresses on all the measurement techniques, ORNL will fabricate ...
2004-09-06
Corrective measures evaluation work plan Technical Area V groundwater.
Energy Technology Data Exchange (ETDEWEB)
This document, which is prepared as directed by the Compliance Order on Consent (COOC) issued by the New Mexico Environment Department, identifies and outlines a process to evaluate remedial alternatives to identify a corrective measure for the Sandia National Laboratories New Mexico Technical Area (TA)-V Groundwater. The COOC provides guidance for implementation of a Corrective Measures Evaluation (CME) for the TA-V Groundwater. This Work Plan documents an initial screening of remedial technologies and presents a list of possible remedial alternatives for those technologies that passed the screening. This Work Plan outlines the methods for evaluating these remedial alternatives and describes possible site-specific evaluation activities necessary to estimate remedy effectiveness and cost. These methods will be reported in the CME Report. This Work Plan outlines the CME Report, including key components and a description of ...
2004-04-01
Corrective measures evaluation work plan : Technical Area V Groundwater : revision 0.
Energy Technology Data Exchange (ETDEWEB)
This document, which is prepared as directed by the Compliance Order on Consent (COOC) issued by the New Mexico Environment Department, identifies and outlines a process to evaluate remedial alternatives to identify a corrective measure for the Sandia National Laboratories/New Mexico Technical Area (TA)-V Groundwater. The COOC provides guidance for implementation of a Corrective Measures Evaluation (CME) for the TA-V Groundwater. This Work Plan documents an initial screening of remedial technologies and presents a list of possible remedial alternatives for those technologies that passed the screening. This Work Plan outlines the methods for evaluating these remedial alternatives and describes possible site-specific evaluation activities necessary to estimate remedy effectiveness and cost. These methods will be reported in the CME Report. This Work Plan outlines the CME Report, including key components and a description of ...
2004-12-01
A high sensitivity two-color interferometer for pulsed power plasmas
International Nuclear Information System (INIS)
A high sensitivity, high bandwidth, two-color interferometer (1064 and 532 nm) has been tested on the Hawk pulsed power generator at the Naval Research Laboratory. The phase resolution is 10"-"5 waves with a rise time of 3 ns, a new capability for diagnosing plasmas, and neutrals in pulsed power experiments. The two-color feature is used to distinguish phase shifts from free (plasma) electrons and bound (neutral and ion) electrons. Simultaneous electron and neutral density measurements were demonstrated in a plasma opening switch (POS) experiment. The ability to measure small phase shifts with fast rise time were demonstrated in a plasma filled diode experiment. The high sensitivity and vibration isolation enable neutral gas distribution measurements from supersonic nozzles used in plasma radiation source experiments. Examples of these measurements and future applications are ...
Two researchers, Tom Goreau of the Discovery Laboratory in Jamaica and Raymond Hayes of Howard University, claim that they have evidence that nearly clinches the temperature connection to the bleached corals in the Caribbean and that the coral bleaching is an indication of Greenhouse warming. The incidents of scattered bleaching of corals, which have been reported for decades, are increasing in both intensity and frequency. The researchers based their theory on increased temperature of the seas measured by satellites. However, some other scientists feel that the satellites measure the temperature of only the top few millimeters of the water and that since corals lie on reefs perhaps 60 to 100 feet below the ocean surface, the elevated temperatures are not significant.
1990-10-12
The Daya Bay reactor neutrino experiment
International Nuclear Information System (INIS)
Search for the value of ?13 mixing angle is of importance in understanding the lepton flavor mixing matrix, and in motivating future experiments to probe CP violation in the lepton sector. Among the present experimental approaches, reactor experiment can provide a clean laboratory for the ?13-measurement. The Daya Bay experiment will start civil construction this year at Daya Bay, Guangdong, China. The goal of this experiment is to reach a sensitivity in sin2 2?13 of < 0.01 at 90% C.L. by precisely measuring the disappearance and spectral distortion of reactor electron anti-neutrinos with multiple identical detectors at different baselines. The talk will present the current status and prospects of the experiment.
2008-07-01
Residual stress measurements on a stress relieved Zircaloy-4 weld by neutron diffraction
Energy Technology Data Exchange (ETDEWEB)
The macroscopic stress distribution across an annealed Zircaloy-4 gas tungsten arc weld was measured by neutron time-of-flight diffraction at the SMARTS diffractometer at Los Alamos National Laboratory. The stresses after annealing are about 40% lower than those in the same weld prior to heat treatment. The intergranular strains in the reference coupons, which give the macroscopic stress free lattice spacings, are consistent with the difference in cooling the strongly textured plate and the weakly textured weld.
2006-12-15
INEEL BNCT research program. Annual report, January 1, 1996--December 31, 1996
Energy Technology Data Exchange (ETDEWEB)
This report is a summary of the progress and research produced for the Idaho National Engineering and Environmental Laboratory (INEEL) Boron Neutron Capture Therapy (BNCT) Research Program for calendar year 1996. Contributions from the individual investigators about their projects are included, specifically, physics: treatment planning software, real-time neutron beam measurement dosimetry, measurement of the Finnish research reactor epithermal neutron spectrum, BNCT accelerator technology; and chemistry: analysis of biological samples and preparation of {sup 10}B enriched decaborane.
1997-04-01
Gamma Radiation Detectors of the TA-55 Waste Line Monitoring System
Energy Technology Data Exchange (ETDEWEB)
This report covers the gamma detectors, measurement instrumentation, and testing results of a system developed at Los Alamos National Laboratory. This system monitors the process liquid waste streams at the Plutonium Facility (TA-55) for the presence of radioactive contamination. The detectors are at various points on the acid, caustic, and industrial waste lines. Two of the detectors are on the sanitary sewer lines from the facility. A custom interface unit associated with these two detectors furnishes the facility operation center with a notification of the detection of material. All of the detectors furnish measurement information to a central computer system for storage and trending.
1999-06-01
Fission neutron multiplicity for the /sup 242m/Am(n,f) reaction
International Nuclear Information System (INIS)
This paper analyzes fission neutron multiplicity for the /sup 242m/Am(n,f) reaction. The fission neutron multiplicity, v bar, of /sup 242m/Am(n,f) was measured relative to that of /sup 235/U(n,f) using the neutron time-of-flight facility at the Lawrence Livermore National Laboratory 100-MeV electron Linac. A comparison of the measured energy dependence of v-bar is made with semi-empirical models of neutron emission from the actinides. 22 refs.
Examination of the natural radioactivity of building materials
International Nuclear Information System (INIS)
Most important radionuclides naturally appearing in minerals used to form building materials are described. The frequently met ranges of concentrations of these radionuclides in the building materials composed from natural products as well as from power-plant wastes and metallurgic plant wastes are discussed and propositions concerning the limitation of presence of radioactive nuclides in the building materials are given, with special concern paid to materials for dwelling and public utility buildings. The elaborated technique of measuring potassium 40, radium 226 and thorium 228 concentrations is presented. Data on the organization of controlling-and-measuring laboratories in this field are given. (author).
1982-01-01
Directional wind-measurement derived from elastic backscatter lidar data in real-time
Energy Technology Data Exchange (ETDEWEB)
The development of a capability to infer wind velocities simultaneously at a number of ranges along one direction in real time is described. The elastic backscatter lidar data used was obtained using the XM94 lidar, developed by Los Alamos National Laboratory for the US Army Chemical and Biological Detection Command. In some respects this problem is simpler than measuring wind velocities on meso-meteorological scales. Other requirements, particularly high temporal fidelity, have driven the development of faster software algorithms and suggested opportunities for the evolution of the hardware.
1996-04-01
Energy Technology Data Exchange (ETDEWEB)
Since 1983, about 600 research projects received a total of DM 250 million public funds for the following tasks: - Development of scientific fundamentals for monitoring and observation of forest decline and its ecological and economic consequences. - Investigation of the cause-effect relationship of forest damage, with particular regard to the involvement of the various compartments of the forest ecosystem and to the contribution of different pollutants. - Development of the scientific fundamentals required for forestry measures to accompany the air pollution abatement measures. The investigations comprised both laboratory and field tests. The findings and conclusion are summarized. (orig./MG).
1988-12-01
A lateral cephalometric study of pharyngeal cavity in Korean adults
International Nuclear Information System (INIS)
A study was performed to investigate the size of pharyngeal cavity and sexual differences between Korean adult mal e and female by introducing linear analysis of the lateral cephalogram. The radiograms were composed of 46 adult male aged 24.64 and 52 adult female aged 22.74 respectively. In order to study and measure the pharyngeal area, the following skeletal landmarks were selected: S,N,A,Ptm, B,H,H', M ,S-N, FH and CV, and the angle CV-FH was measured to provide a factor for correction of error resulting from improper he ad positioning of subjects, especially in the relative positions of A and H, while radiography. All points to be measured were projected at right angles to the Frankfort plane. For the purpose of measuring the anteroposterior dimensions of pharyngeal cavity the distances were measured in A-Ptm, A-S, S-Ptm and CV-H, and vertical ...
1976-11-01
International Nuclear Information System (INIS)
In the convolution/superposition algorithm, the energy spectrum should be modified to make the reconstructed dose distribution consistent with the measured dose distribution. The energy spectrum, which gives the best agreement, is not determined uniquely depending on the reconstruction procedure. In this report, the effects of the characteristics of the energy spectrum on the calculation accuracy are evaluated by comparing the percentage depth dose (PDD) and beam profiles for the reference energy spectrum with those calculated for the modified spectrum in order to optimize the energy spectrum modification procedure when 4 and 10 MV X-ray beams are used. Decreasing the number of energy bins brought a larger decrease rate in the computation accuracy than a decrease rate in computation time. Further, the decrease of the number of energy bins led to a change of the energy spectrum. The balance of the relative fluence weight in a each bin and its average energy, which ...
2003-06-01
Study of scalar leptons at the TESLA Photon Collider
International Nuclear Information System (INIS)
In this thesis, the potential to discover supersymmetric signatures in both e"+e"- and #gamma##gamma# colliders evaluated with a Monte Carlo analysis, is discussed. The analysis was focused on the detection of muons, essentially. First, we study the detection of #mu#"+_R#mu#"-_R in e"-e"+ collisions, whose purpose is the measurement of the #mu#_R mass. It was found that an uncertainty of 0.11 GeV (stat) can be achieved. Under the assumption of the real conditions of the ILC photon collider, a study covering the detection of #mu#"+_R#mu#"-_R and #mu#"+_L#mu#"-_L pairs for #sq root#(s_e_"-_e_"+)=0.5 and 0.6 TeV was performed. According to the simulation, a statistical error for the branching ratios of #mu#"#+-#_L#->##chi#"0_1#mu#"#+-# of 0.98% and #mu#"#+-#_L#->##chi#"0_2#mu#"#+-# of 3.97% can be reached. In order to judge the Monte Carlo results, we have used a technique based on a multidimensional fit to evaluate the impact of the ...
International Nuclear Information System (INIS)
Growing of PV for electricity generation is one of the highest in the field of the renewable energies and this tendency is expected to continue in the next years. Due to the various seasonal, hourly and daily changes in climate, it is relatively difficult to find a suitable analytic model for predicting the performance of a grid-connected photovoltaic (GCPV) plant. In this paper, an artificial neural network is used for modelling and predicting the power produced by a 20 kWp GCPV plant installed on the roof top of the municipality of Trieste (latitude 45 deg. 40'N, longitude 13 deg. 46'E), Italy. An experimental database of climate (irradiance and air temperature) and electrical (power delivered to the grid) data from January 29th to May 25th 2009 has been used. Two ANN models have been developed and implemented on experimental climate and electrical data. The first one is a multivariate model based on the solar irradiance and the air temperature, while the second one is an univariate ...
2010-12-01
Energy Technology Data Exchange (ETDEWEB)
ICP emission analyses are prone to errors due to changes in power level, nebulization rate, plasma temperature, and sample matrix. As a result, accurate analyses of complex samples often require frequent bracketing with matrix matched standards. Information needed to track and correct the matrix errors is contained in the emission spectrum. But most commercial software packages use only the analyte line emission to determine concentrations. Changes in plasma temperature and the nebulization rate are reflected by changes in the hydrogen line widths, the oxygen emission, and neutral ion line ratios. Argon and off-line emissions provide a measure to correct the power level and the background scattering occurring in the polychromator. The authors` studies indicated that changes in the intensity of the Ar 404.4 nm line readily flag most matrix and plasma condition modifications. Carbon lines can be used to monitor the impact of ...
1997-10-01
British Library Electronic Table of Contents (United Kingdom)
Over a 6.5-year period a total of 2554 values were reported by nine laboratories for 259 certified or reference nutrient concentrations in 26 certified reference materials (CRM) submitted to contract laboratories, blinded, as part of the qualifying process for analytical contracts and in the routine sample stream as part of the National Food and Nutrient Analysis Program. Each value was converted to a Z?-score, reflecting the difference from the assigned value related to the combined expected analytical uncertainty plus the uncertainty in the CRM value. Z?-scores >|3.0| were considered unacceptable. For some nutrients (Na, folate, dietary fiber, pantothenic acid, thiamin, tocopherols, carotenoids, monounsaturated, and polyunsaturated fatty acids), >20% of Z?-scores were >|3.0|. For total f...
2007-01-01
Neutron star evolution and emission
This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The authors investigated the evolution and radiation characteristics of individual neutron stars and stellar systems. The work concentrated on phenomena where new techniques and observations are dramatically enlarging the understanding of stellar phenomena. Part of this project was a study of x-ray and gamma-ray emission from neutron stars and other compact objects. This effort included calculating the thermal x-ray emission from young neutron stars, deriving the radio and gamma-ray emission from active pulsars and modeling intense gamma-ray bursts in distant galaxies. They also measured periodic optical and infrared fluctuations from rotating neutron stars and search for high-energy TeV gamma rays from discrete celestial sources.
1997-08-01
Energy Technology Data Exchange (ETDEWEB)
This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at Los Alamos National Laboratory (LANL). The primary aim of this project is to obtain a basic scientific understanding of electrical transport processes at interfaces that contain an organic electronic material. Because of their processing advantages and the tunability of their electronic properties, organic electronic materials are revolutionizing major technological areas such as information display. We completed an investigation of the fundamental electronic excitation energies in the prototype conjugated polymer MEH-PPV. We completed a combined theoretical/experimental study of the energy relation between charged excitations in a conjugated polymer and the metal at a polymer/metal interface. We developed a theoretical model that explains injection currents at polymer/metal interfaces. We have made electrical ...
1999-06-04
Insitu Assessment of Contaminant Containment Systems
Environmental Research Database
Objectives(1) Evaluate various insitu techniques for determination of the permeability of slurry walls and investigate the extent of material disturbance and fracturing during drilling and testing.~%~~%~(2) Perform laboratory tests of block samples obtained from the field testing site and compare the results with field measurements.~%~~%~(3) Investigate the mechanisms of drilling using a newly developed instrumented self-boring device and develop a theoretical framework for drilling mechanisms in soils.~% [continued...]DescriptionCement-bentonite and clay liner systems are used as components of containment systems by the environmental industry to control the migration of pollution. In the interest of public safety, following construction, there is a requirement to test these structures in orde to assess if they meet the design critetia. At present this is done only indirectly via ...
2006-01-30
Energy Technology Data Exchange (ETDEWEB)
Co-combustion of chicken litter with coal was performed in a laboratory-scale fluidized bed combustor to investigate the effect of chicken litter addition on the partitioning behavior of mercury. Gaseous total and elemental mercury concentrations in the flue gas were measured online, and ash was analyzed for particle-bound mercury along with other elemental and surface properties. The mercury mass balance was between 85 and 105%. The experimental results show that co-combustion of chicken litter decreases the amount of elemental and total mercury in the gas phase. Mercury content in fly ash increases with an increasing chicken litter share. 22 refs., 6 figs., 5 tabs.
2008-07-15
Explosive performance on the non-proliferation experiment
Energy Technology Data Exchange (ETDEWEB)
The non-proliferation experiment, originally called the chemical kiloton experiment, was planned and executed by Lawrence Livermore National Laboratory to investigate the seismic yield relationship and distinguishing seismic signals between a nuclear event and a large mass conventional explosion. The Los Alamos National Laboratory planned and conducted experiments to further their studies of the source function for signals observed seismically. Since all investigations were contingent on the performance of the emplaced chemical explosive, an array of diagnostic measurements was fielded in the emplaced explosive. The CORRTEX system was used to investigate the explosive initiation and to determine the detonation velocities in multiple levels and in numerous directions. A description of the CORRTEX experiments fielded, a review of the data obtained and some interpretations of the data are reported.
1994-03-01
EBIT - Electronic Beam Ion Trap: N Divison experimental physics annual report 1995
Energy Technology Data Exchange (ETDEWEB)
The multi-faceted research effort of the EBIT (Electron Beam Ion Trap) program in N-Division of the Physics and Space Technology Department at Lawrence Livermore National Laboratory (LLNL) continues to contribute significant results to the physical sciences from studies with low energy very highly charged heavy ions. The EBIT program attracts a number of collaborators from the US and abroad for the different projects. The collaborations are partly carried out through participating graduate students demonstrating the excellent educational capabilities at the LLNL EBIT facilities. Moreover, participants from Historically Black Colleges and Universities are engaged in the EBIT project. This report describes EBIT work for 1995 in atomic structure measurements and radiative transition probabilities, spectral diagnostics for laboratory and astrophysical plasmas, ion/surface interaction studies, electron-ion interactions studies, ...
1996-10-01
British Library Electronic Table of Contents (United Kingdom)
As part of the United States Department of Agricultures (USDA) National Food and Nutrient Analysis Program (NFNAP), food composition data for vitamin D in the USDA National Nutrient Database for Standard Reference are being updated and expanded, focusing on high priority foods and validated analytical methodology. A lack of certified reference materials and analytical methods validated for these key foods required the development of five matrix-specific control composite materials (CC) (canned salmon and vitamin D3 fortified cereal, orange juice, milk, and cheese). Each of six experienced laboratories (research and commercial) analyzed vitamin D3 in five subsamples of each CC in five separate analytical batches, with one subsample of each material in each run. Research laboratories perform...
2008-01-01
Systems Analysis of Safeguards Effectiveness in a Uranium Conversion Facility
Energy Technology Data Exchange (ETDEWEB)
The U.S. Department of Energy (DOE) is interested in developing tools and methods for potential U.S. use in designing and evaluating safeguards systems. For this goal several DOE National Laboratories are defining the characteristics of typical facilities of several size scales, and the safeguards measures and instrumentation that could be applied. Lawrence Livermore National Laboratory is providing systems modeling and analysis of facility and safeguards operations, diversion path generation, and safeguards system effectiveness. The constituent elements of diversion scenarios are structured using directed graphs (digraphs) and fault trees. Safeguards indicator probabilities are based on sampling statistics and/or measurement accuracies. Scenarios are ranked based on value and quantity of material removed and the estimated probability of non-detection. Significant scenarios, especially those involving ...
2004-06-16
Radioxenons: Their role in monitoring a Comprehensive Test Ban Treaty
Energy Technology Data Exchange (ETDEWEB)
Monitoring for xenon radionuclides which are produced in a nuclear detonation can provide a strong deterrent to the violation of a Comprehensive nuclear Test Ban Treaty (CTBT). There are 18 known radioactive xenon isotopes produced in nuclear fission with half-lives ranging from less than one second to 11.9 days. However, only four of these remain in significant amounts more than a day after a detonation. In order for radioxenon monitoring to be practical, it was necessary to develop an automated measurement system which could operate unattended for periods of months, measure the entire spectrum of radioxenons, and provide hundreds of times better sensitivities than current laboratory procedures. This capability was developed at the US Department of Energy`s Pacific Northwest National Laboratory based on rapid separation of atmospheric xenon coupled with a unique high sensitivity ...
1996-06-01
Performance of the upgraded LTP-II at the ALS Optical Metrology Laboratory
Energy Technology Data Exchange (ETDEWEB)
The next generation of synchrotrons and free electron laser facilities requires x-ray optical systems with extremely high performance, generally of diffraction limited quality. Fabrication and use of such optics requires adequate, highly accurate metrology and dedicated instrumentation. Previously, we suggested ways to improve the performance of the Long Trace Profiler (LTP), a slope measuring instrument widely used to characterize x-ray optics at long spatial wavelengths. The main way is use of a CCD detector and corresponding technique for calibration of photo-response non-uniformity [J. L. Kirschman, et al., Proceedings of SPIE 6704, 67040J (2007)]. The present work focuses on the performance and characteristics of the upgraded LTP-II at the ALS Optical Metrology Laboratory. This includes a review of the overall aspects of the design, control system, the movement and measurement regimes for the stage, and analysis of the ...
2008-07-14
Isochron measurements of naturally irradiated K-feldspar grains
International Nuclear Information System (INIS)
The equivalent doses of K-feldspar grains in a range of grain sizes from 90 to 250#mu#m diameter were measured using a single-aliquot regenerative-dose protocol for the infrared stimulated luminescence (IRSL) signals for two samples of desert sand. The equivalent doses for each sample were compared with that for the 125-150#mu#m grains of quartz from the same samples. The results suggested that the K-feldspar equivalent doses were underestimated because of anomalous fading. Measurements of the decay of the IRSL signals following laboratory irradiation for these two samples, and an additional one from a previously published isochron study, showed anomalous fading during the period of laboratory storage. The decay rate was about 3% per decade for all samples and was independent of the grain size used. Using plots of equivalent doses for K-feldspars as a function of their calculated internal dose rate, and ...
2007-09-01
Superconducting gravity gradiometer for sensitive gravity measurements. I. Theory
Energy Technology Data Exchange (ETDEWEB)
Because of the equivalence principle, a global measurement is necessary to distinguish gravity from acceleration of the reference frame. A gravity gradiometer is therefore an essential instrument needed for precision tests of gravity laws and for applications in gravity survey and inertial navigation. Superconductivity and SQUID (superconducting quantum interference device) technology can be used to obtain a gravity gradiometer with very high sensitivity and stability. A superconducting gravity gradiometer has been developed for a null test of the gravitational inverse-square law and space-borne geodesy. Here we present a complete theoretical model of this instrument. Starting from dynamical equations for the device, we derive transfer functions, a common mode rejection characteristic, and an error model of the superconducting instrument. Since a gradiometer must detect a very weak differential gravity signal in the midst of large platform ...
1987-06-15
Energy Technology Data Exchange (ETDEWEB)
Swirling speed in a direct injection diesel engine was measured by a laser doppler velocimeter. Intake port geometry and engine speed were changed as factors affecting the swirling flow to study the distribution of swirling flow speed. The distribution of swirling flow speed changes complicatedly owing to axial nonsymmetry during intake process but becomes simple shape of axial symmetry during compression process after closing intake valve. But if this is assumed as the rigid swirl shape, the difference due to each intake port cannot be expressed but also large error may be possible to appear close to the cylinder wall. The distribution of swirling flow speed during compression process changes similarly, nearly proportinal to engine speed. But the similarity is higher at the middle period in compression process than at the end period in compression period. Axial distribution of local swirling ratio during compression process is nearly uniform. ...
1989-05-31
Electron momentum spectroscopy of H_2 and D_2: Ionization to ground and excited final states
International Nuclear Information System (INIS)
The symmetric noncoplanar (e,2e) cross sections (momentum profiles) of H_2 and D_2 for the transitions to the 2p#sigma#_u and 2s#sigma#_g excited ion states have been measured, relative to the ground-state ion transition, using a high-sensitivity multichannel momentum-dispersive electron momentum spectrometer (EMS) at an impact energy of 1200 eV. Newly calculated plane-wave impulse approximation (PWIA) cross sections, based on a full-configuration-interaction H_2 wave function, are compared to the experimental results. These calculations are in better agreement with the experimental results for the transition to the 2s#sigma#_g ion state than the earlier theoretical work of Liu and Smith, Jr. [Phys. Rev. A 31, 3003 (1985)] which has been found to be in error. Nevertheless, significant discrepancies between the relative experimental and theoretical cross sections are observed for the transitions to excited ion states, suggesting a failure of the ...
Energy Technology Data Exchange (ETDEWEB)
Heat transfer through the gas diffusion layer (GDL) is a key process in the design and operation of a PEM fuel cell. The analysis of this process requires determination of the effective thermal conductivity as well as the thermal contact resistance associated with the interface between the GDL and adjacent surfaces/layers. In the present study, a custom-made test bed that allows the separation of effective thermal conductivity and thermal contact resistance in GDLs under vacuum and ambient conditions is described. Measurements under varying compressive loads are performed using Toray carbon paper samples with a porosity of 78% for a range of thicknesses. The measurements are complemented by compact analytical models that achieve good agreement with experimental data. A key finding is that thermal contact resistance is the dominant component of the total thermal resistance; neglecting this phenomenon may result in significant ...
2011-01-01
Development of swing-free / shock free crane
Energy Technology Data Exchange (ETDEWEB)
To develop the automatized crane and to apply the relevant technology to nuclear power plants, in this project and automatized crane control system is developed along with a swing and shock crane. Also, this technology has been transferred to Bando Machinery Co. Ltd. The drive mechanism of crane is designed by adopting vector drives which provide soft acceleration and deceleration characteristics. Also, radio modems and a long-range laser displacement sensor which are commercially available are introduced to accommodate the large scaled crane systems. Also, several devices are developed for the automation of crane system. These are a crane controller, a supervisory controller, a angle measuring device, and laser localizer, a drum grapple device, and crane supervisory program. The performance of developed crane system is revealed to rapidly reduce the residual swingof the transported object and precisely controls the object position in any case. Also, the laser ...
1999-04-01
Accuracy improvement of T-history method for measuring heat of fusion of various materials
Energy Technology Data Exchange (ETDEWEB)
T-history method, developed for measuring heat-of-fusion of phase change material (PCM) in sealed tubes, has the advantages of a simple experimental device and convenience with no sampling process. However, some improper assumptions in the original method, such as using a degree of supercooling as the end of latent heat period and neglecting sensible heat during phase change, can cause significant errors in determining the heat of fusion. We have improved this problem in order to predict better results. The present study shows that the modified T-history method is successfully applied to a variety of PCMs such as paraffin and lauric acid having no or a low degree of supercooling. Also it turned out that selected periods for sensible and latent heat do not significantly affect the accuracy of heat- of-fusion. As a result, the method can provide an appropriate means to assess a newly developed PCM by a cycle test even if a very accurate value ...
2004-06-01
International Nuclear Information System (INIS)
Accurate dose calculation in radiation treatment planning is most important for successful treatment. Since human body is composed of various materials and not an ideal shape, it is not easy to calculate the accurate effective dose in the patients. Many methods have been proposed to solve inhomogeneity and surface contour problems. Monte Carlo simulations are regarded as the most accurate method, but it is not appropriate for routine planning because it takes so much time. Pencil beam kernel based convolution/superposition methods were also proposed to correct those effects. Nowadays, many commercial treatment planning systems have adopted this algorithm as a dose calculation engine. The purpose of this study is to verify the accuracy of the dose calculated from pencil beam kernel based treatment planning system comparing to Monte Carlo simulations and measurements especially in inhomogeneous region. Home-made inhomogeneous phantom, Helax-TMS ver. 6.0 and Monte ...
2002-10-20
The Preliminary GAMMA Code Thermal hydraulic Analysis for the Steady State of HTR-10 Initial Core
Energy Technology Data Exchange (ETDEWEB)
This report describes the preliminary thermalhydraulic analysis of HTR-10 steady state full power initial core to provide a benchmark calculation of VHTGR(Very High-Temperature Gas-Cooled Reactors) safety analysis code of GAMMA(GAs Multicomponent Mixture Analysis). The input data of GAMMA code are produced for the models of fluid block, wall block, radiation heat transfer and each component material properties in HTR-10 reactor. The temperature and flow distributions of HTR-10 steady state 10 MW{sub th} full power initial core are calculated by GAMMA code with boundary conditions of total reactor inlet flow rate of 4.32 kg/s, inlet temperature of 250 .deg. C, inlet pressure of 3 MPa, outlet pressure of 2.992 MPa and the fixed temperature at RCCS water cooling tube of 50 .deg C. The calculation results are compared with the measured solid material temperatures at 22 fixed instrumentation positions in HTR-10. The wall temperature distribution in pebble bed core shows ...
2006-07-15
Energy Technology Data Exchange (ETDEWEB)
Q/sub ..beta..-values are determined for 18 nuclei (Zr-, Nb-, Mo-, Tc-, Ru- and Rh-nuclides) with mass numbers 101 less than or equal toA less than or equal to106 and A=109 from measurements of beta decay energies which were carried out at the LOHENGRIN mass separator at the Institut Laue-Langevin in Grenoble (France). The given Q/sub ..beta..-values between 2 and 8 MeV show errors of about 1.5% (with the exception of /sup 103/Zr and /sup 105/Nb resp. and /sup 103/Tc for which larger errors result due to statistical resp. systematic reasons): /sup 101/Zr 5500+-70, /sup 101/Nb 4580+-45, /sup 102/Zr 4670+-40, /sup 102/Nb 7230+-70, /sup 103/Zr 6790+-240, /sup 103/ 5740+-70, /sup 103/Mo 3575+-80, /sup 103/Tc 2585+-70, /sup 104/Nb 8250+-130, /sup 104/Mo 2180+-40, /sup 104/Tc 5520+-100, /sup 105/Nb 6570+-150, /sup 105/Mo 4885+-80, /sup 105/Tc 3750+-60, /sup 106/Mo 3515+-45, /sup 106/Tc 6540+-70, /sup 109/Ru 4150+-80, /sup 109/Rh ...
1986-10-31
International Nuclear Information System (INIS)
Q_#beta#-values are determined for 18 nuclei (Zr-, Nb-, Mo-, Tc-, Ru- and Rh-nuclides) with mass numbers 101 #<=# A #<=# 106 and A=109 from measurements of beta decay energies which were carried out at the LOHENGRIN mass separator at the Institut Laue-Langevin in Grenoble (France). The given Q_#beta#-values between 2 and 8 MeV show errors of about 1.5% (with the exception of "1"0"3Zr and "1"0"5Nb resp. and "1"0"3Tc for which larger errors result due to statistical resp. systematic reasons): "1"0"1Zr 5500#+-#70, "1"0"1Nb 4580#+-#45, "1"0"2Zr 4670#+-#40, "1"0"2Nb 7230#+-#70, "1"0"3Zr 6790#+-#240, "1"0"3 5740#+-#70, "1"0"3Mo 3575#+-#80, "1"0"3Tc 2585#+-#70, "1"0"4Nb 8250#+-#130, "1"0"4Mo 2180#+-#40, "1"0"4Tc 5520#+-#100, "1"0"5Nb 6570#+-#150, "1"0"5Mo 4885#+-#80, "1"0"5Tc 3750#+-#60, "1"0"6Mo 3515#+-#45, "1"0"6Tc 6540#+-#70, "1"0"9Ru 4150#+-#80, "1"0"9Rh 2550#+-#50 (all values in keV). For the ...
The relationship between plasma testosterone levels and locomotor activity in wild-caught sexually mature male meadow voles (Microtus pennsylvanicus) was assessed in the laboratory. Several aspects of locomotor activity were monitored for 1 h on two consecutive days using the automated Digiscan activity monitoring system. Plasma testosterone levels were determined immediately following the second day of activity monitoring. Significant Pearson correlations were obtained between plasma testosterone levels and total distance traveled [r(10) = 0.55, p < 0.05] and amount of time spent in movement [r(10) - 0.55, p < 0.05] on the second day. The wild voles showed a reduction in activity levels from the first to the second day of activity monitoring, which is indicative of habituation to a novel environment. This study provides direct evidence for a significant correlation between laboratory measures of behavioral activity ...
1998-04-01
Advances on experimental techniques for the characterization of THM behaviour of bentonite
Energy Technology Data Exchange (ETDEWEB)
The design of high level radioactive waste (HLW) repositories in deep geological media in which bentonite clay is proposed as a sealing material leads to the need of further studying the behaviour of highly compacted expansive soils when subjected to mechanical, hydraulic and thermal changes. Laboratory tests may help to understand the processes that take place in the clay barrier under simple and controlled conditions and to develop the governing equations. The laboratory tests enable to isolate the different processes, making their interpretation easier, and provide with fundamental data concerning the parameters to be used in the models. The extremely low permeability of these materials, their avidity for water (high suction) and their high swelling capacity make necessary the modification of the conventional laboratory techniques and procedures to determine basic physical parameters. The main hydraulic properties of the ...
2005-07-01
UK PubMed Central (United Kingdom)
Young men's errors in sexual perception have been linked to sexual coercion. The current investigation sought to explicate the perceptual and decisional sources of these social perception errors,...Full Text Available
2010-01-01
Impact of Basic Computerized Prescribing on Outpatient Medication Errors and Adverse Drug Events
UK PubMed Central (United Kingdom)
Few data exist about the impact of computerized prescribing systems on outpatient medication errors (MEs) and adverse drug events (ADEs). We compared the rates of MEs and ADEs in handwritten sites versus...Full Text Available
2002-11-01
Energy Technology Data Exchange (ETDEWEB)
There are clearly identified scientific requirements for continuous profiling of atmospheric water vapor at the Department of Energy, Atmospheric Radiation Measurement program, Southern Great Plains CART (Cloud and Radiation Testbed) site in northern Oklahoma. Research conducted at several laboratories has demonstrated the suitability of Raman lidar for providing measurements that are an excellent match to those requirements. We have developed and installed a ruggedized Raman lidar system that resides permanently at the CART site, and that is computer automated to eliminate the requirements for operator interaction. In addition to the design goal of profiling water vapor through most of the troposphere during nighttime and through the boundary layer during daytime, the lidar provides quantitative characterizations of aerosols and clouds, including depolarization measurements for particle phase studies.
1997-12-31
Thermal electron attachment and detachment, and electron affinities
International Nuclear Information System (INIS)
Knighton et al. used a pulsed high pressure mass spectrometer to examine thermal electron detachment from C_6F_6"-. This technique had been used earlier for the measurement or detachment rate coefficients for azulene anions as a function of temperature. C_6F_6"- and c-C_4F_6"- have been studied by Datskos et al. using a pulsed drift tube. In our laboratory, we have used a flowing afterglow Langmuir probe (FALP) apparatus to measure the thermal electron detachment rate coefficient for c-C_4F_8"- ions at 375 K. We have also measured the electron attachment rate coefficient for c-C_4F_8 at 303 K and 375 K. (author).
1994-03-20
Neutrino cross sections with the MINER?A Experiment
British Library Electronic Table of Contents (United Kingdom)
MINER?A is a high resolution, fully active detector designed to study neutrino interactions on nuclei in the NuMI beam at Fermi National Accelerator Laboratory. The active volume of the detector consists of 3 tons of plastic scintillator and includes embedded targets of 4He, C, H2O, Fe and Pb. The MINER?A collaboration expects to perform precision, A-dependent neutrino cross section measurements in the 1?10 GeV region, measure the axial form factor, and study nuclear shadowing of F2, quark-hadron duality and coherent pion production, among other topics. MINER?A began data taking in the fall of 2009. This paper describes the MINER?A experiment and provides an overview of the physics objectives along with estimated uncertainties of the measurements and the tentative projected schedule of dat...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
Indoor and soil gas Radon (222Rn) concentration measurements were accomplished in two stages in Sivas, a central eastern city in Turkey. In the first stage, CR-39 passive nuclear track detectors supplied by the Turkish Atomic Energy Authority (TAEA) were placed in the selected houses throughout Sivas centrum in two seasons; summer and winter. Before the setup of detectors, a detailed questionnaire form was distributed to the inhabitants of selected houses to investigate construction parameters and properties of the houses, and living conditions of inhabitants. Detectors were collected back two months later and analysed at TAEA laboratories to obtain indoor 222Rn gas concentration values. In the second stage, soil gas 222Rn measurements were performed using an alphameter near the selected h...
2010-01-01
Characteristics of infrared-stimulated luminescence from a feldspar at low temperatures
International Nuclear Information System (INIS)
The characteristics of infrared-stimulated luminescence (IRSL) from a sample of potassium feldspar at low temperatures are presented. These studies extend the previous work from this laboratory on the optical bleaching characteristics and emission spectra of feldspars at room temperature and recent measurements of the stimulated spectrum for a sample of potassium feldspar at room temperature. Stimulation spectra have been measured at 290, 160 and 145 K. By fitting Gaussian functions to the spectra, the peak position is shown to shift to higher photon energies at lower temperatures and the full-width half-maximum of the peak to reduce with decreasing temperature. The variation of IRSL intensity with temperature for several stimulating wavelengths has been determined and the form of the IRSL decay curve measured at 290 and 160 K. No substantial differences were observed in the form of the decay curves at ...
1993-07-01
Energy Technology Data Exchange (ETDEWEB)
The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center (TMC) at the DOE Grand Junction Projects Office (GJPO) in Grand Junction, Colorado, to standardize, calibrate, and compare measurements made in support of DOE remedial action programs. Outdoor radon concentration measurements were made by the TMC in Shiprock, New Mexico, to compare two different methods of measuring radon in an attempt to determine the feasibility of using passive alpha-track detectors to assess the adequacy of remedial action undertaken at the Shiprock uranium mill tailings pile. The results of the first three quarters of monitoring have been detailed in previous reports. An analysis of the data from the fourth quarter of monitoring at Shiprock reveals a somewhat poorer correlation between the two sets of measurements than was seen in the ...
1988-08-01
Energy Technology Data Exchange (ETDEWEB)
Field data for validating plume models were collected in and around the Bull Run Steam Plant during two four-week periods between July and October, 1982. The field measurements were the second phase of the Plume Model Validation and Development (PMV and D) program. The Bull Run Steam Plant is located near Oak Ridge, Tennessee, and the area is described as the ''Moderately Complex Site'' to distinguish it from the ''Plains Site'' in eastern Illinois, which was the scene of the first phase of the PMV and D study conducted in 1980-81. The measurement program consisted of a set of meteorological, source, aerometric, and tracer measurements to track and characterize the plume. The tracer measurements constituted the largest portion of the total effort, and it involved the release of SF/sub 6/ tracer gas from the stack, and the sampling ...
1985-05-01
Energy Technology Data Exchange (ETDEWEB)
The central topic of this work is the study of the properties and the implementation of a Paul trap used for the measurement of the beta-neutrino angular correlation parameter in the decay of {sup 6}He. This coefficient provides a signature of the nature of the interactions involved in the weak interaction. The value of this coefficient can be deduced from the kinematical distribution of the decay events. An electromagnetic trap is used for the trapping of {sup 6}He{sup +} ions in a small volume. This trap has an open geometry that enables the detection in coincidence of the electron and the recoil ion emitted in the beta decay. A dedicated detection set up is used for the measurement of the electron energy, the ion time of flight and the position of the two particles for each event. A general description of the LPCTrap facility and of its performances is presented and shows that this set up is able to fulfill the proposed ...
2007-07-15
International Nuclear Information System (INIS)
The purpose of this study is to evaluate the accuracy of dose calculations by three algorithms. Depth dose, OPF (Output Factor) and dose profiles were measured in a heterogeneous phantom. These values were also calculated by three algorithms of the Batho power law (BPL), Equivalent-Tissue Air Ratio (ETAR) and Convolution superposition (CS). The data were obtained for 4, 6 and 10 MV photon beams with a linear accelerator (Varian 21EX). Field size ranged from 3 x 3 cm"2 to 10 x 10 cm"2. Dose profiles of beam penumbra were also measured by a 0.125 ml ionization chamber at the point of 8, 13 and 18 cm from the surface of the phantom at intervals of 1 mm. Differences between measured and calculated depth doses were within 2% in BPL and CS, but depth doses were overestimated in ETAR. OPFs were also overestimated with the error of more than 4% in ETAR. Absorbed dose calculated by CS were in agreement with the ...
2004-12-01
Energy Technology Data Exchange (ETDEWEB)
Aggregation of fine-resolution land-cover maps to coarser scales indicates that estimates of the proportions of land-cover types vary as a function of spatial resolution. The magnitude of these proportional errors in a forested area in northern California increase significantly as resolution exceeds a 90-m threshold. These errors could pose difficulties for the use of land-cover products generated from coarse-resolution sensors such as the NOAA-AVHRR and the MODIS sensor planned for the EOS program. The magnitude of the errors appears to be a function of the spatial resolution of the map, the original size of the land-cover classes, and the spatial patterns of the classes.
1994-05-01
A Kalman Filter Clock Algorithm for Use in the Presence of ...
... Following the application of the error covariance update equation, we apply the following operation to the parameter covariance matrix P+: ...
2004-09-01
down inertial navigation systemshavebeenreported. Shibata (1986)describesthe strapdown inertial navigation error equations basedon a quaternion relationship ...
"2"0"3Pb yields while irradiating thallium with protons and deuterons
International Nuclear Information System (INIS)
... data deuteron beams energy dependence errors gamma radiation lead 203
Use of a predictor for total body potassium content: application to nutrition and hypertension
International Nuclear Information System (INIS)
Total body potassium (TBK), measured at different institutions, has no reference standard for comparison. A useful reference formula, however, based on body size and age, has been derived at the Brookhaven National Laboratory. This formula was used to help calibrate a simple whole body counter for measuring total potassium and applied to nutrition and hypertension studies. A sodium iodide detector was used for counting gamma rays emitted by potassium-40 to estimate TBK. The mean ratio (+/- S.D.) of adjusted TBK measurements to predicted values was 1.002 +/- 0.047. The ratio of lean body mass estimated by the TBK measurement to that derived from skin fold thickness was 1.069 +/- 0.056. In hypertensives on low dose thiazide, the ratio of TBK measurements to predicted values was 0.994 +/- 0.052. Thus, our TBK measurements were adjusted in close ...
The models of experimental magnetic measurements of various biological samples
International Nuclear Information System (INIS)
Complete text of publication follows. At the Geomagnetic Institute, in the Laboratory for paleomagnetism and archeomagnetism research and at the Geomagnetic Observatory, Grocka (GCK) during the period from November 2004 to February 2008 the researchers carried out experimental magnetic measurements of the total-intensity gradient of the magnetic field vector (changes in the total magnetisation vector) of various biomaterials. Measurements of the gradient total intensity of the magnetic field vector were carried out by GSM-19 magnetometers of high accuracy and recording resolution (accuracy: #DELTA#F=0.1 nT; sampling rate: 1-5 per second). During these experimental biomagnetic measurements samples of water, tissue, blood, cotton, wool, pitch and magnetite-powder were used. In this study, the part of the biomagnetic measurement results relate to the water, blood and tissue. The ...
2009-08-23
Effect of borehole size, mudcake, and standoff on the photoelectric absorption index measurement
Energy Technology Data Exchange (ETDEWEB)
The photoelectric absorption index, I/sub Pe/, is accepted as an accurate measurement for the description of formation lithology. The measured I/sub Pe/ has been shown to deviate slightly for a given lithology because of the effects of porosity. Properly calibrated and measured I/sub Pe/'s, however, have been observed to deviate from predicted values in practice, even considering the influence of porosity. Such departures were traced to variations in borehole size and tool standoff. The nature of the physical method of recording an I/sub Pe/ does not ensure independence from the influence of the borehole environment. A series of laboratory experiments has been conducted in test formations to verify and to characterize the influence of borehole size, mudcake, and standoff on I/sub Pe/ measurement. A set of nomographs has been constructed that allows correction of I/sub Pe/ ...
1989-06-01
Numerical error analysis of direct integration method
Energy Technology Data Exchange (ETDEWEB)
Numerical errors of PALLAS calculation due to spatial mesh sizes are examined for a typical deep penetration shielding problem of isotropic incident fission neutrons penetrating a 200-cm-thick water slab. The exponential approximation for the source spatial distribution to solve the transport equation based on the direct integration method is verified to be effective for radiation transport in attenuating medium, while the linear approximation employed in the old PALLAS code is found to produce large errors for calculations with large mesh sizes.
1986-01-01
International Nuclear Information System (INIS)
Korea Atomic Energy Research Institute, using the ANS low power and shutdown (LPSD) probabilistic risk assessment (PRA) Standard, evaluated the LPSD PSA model of the KSNP, Yonggwang Units 5 and 6, and identified the items to be improved. The evaluation results of human reliability analysis (HRA) of the post-accident human errors in the LPSD PSA model for the KSNP showed that 10 items among 19 items of supporting requirements for those in the ANS PRA Standard were identified as them to be improved. Thus, we newly carried out a HRA for post-accident human errors in the LPSD PSA model for the KSNP. Following tasks are the improvements in the HRA of post-accident human errors of the LPSD PSA model for the KSNP compared with the previous one: Interviews with operators in the interpretation of the procedure, modeling of operator actions, and the quantification results of human errors, site visit. Applications ...
2010-05-01
Uranium isotopic assay instrument
International Nuclear Information System (INIS)
Full text: The isotopic assay instrument under development at Pacific Northwest National Laboratory (PNNL) is capable of rapid prescreening to detect small and rare particles containing high concentrations of uranium in a heterogeneous sample. The isotopic measurement concept is based on laser vaporization of solid samples followed by sensitive isotope-specific detection using either uranium atomic fluorescence emission or uranium atomic absorbance. Both isotopes are measured concurrently, following a single ablation laser pulse using two external-cavity violet diode lasers. The simultaneous measurement of both isotopes enables the correlation of the fluorescence and absorbance signals on a shot-to-shot basis. This measurement approach demonstrated negligible channel crosstalk between isotopes. Scanning the heterogeneous samples provides high-resolution imagery of sample isotopic ...
2006-10-16
Intercomparison of Retrospective Radon Detectors
Energy Technology Data Exchange (ETDEWEB)
We performed both a laboratory and field intercomparison of two novel glass-based retrospective radon detectors previously used in major radon case-control studies performed in Missouri and Iowa. The new detectors estimate retrospective residential radon exposure from the accumulation of a long-lived radon decay product, Pb-210, in glass. The detectors use track registration material in direct contact with glass surfaces to measure the alpha emission of a Pb-210 decay product, Po-210. The detector's track density generation rate (tracks cm{sup -2} hr{sup -1}) is proportional to the surface alpha activity. In the absence of other strong sources of alpha emission in the glass, the implanted surface alpha activity should be proportional to the accumulated Po-210 and hence, the cumulative radon gas exposure. The goals of the intercomparison were to: (1) perform collocated measurements using two different glass-based ...
1998-11-01
Total suspended matter observation in the Pearl River estuary from in situ and MERIS data.
Based on the cruise data collected in the Pearl River estuary (PRE) in May 2008, an empirical two-band model by using the ratio of R (rs) at 629 and 671 nm was established to retrieve total suspended matter (TSM) concentration with the determination coefficient (R(2)) of 0.854, mean relative error (MRE) of 7.483%, and root-mean-square error (RMSE) of 1.295 mg L(?-?1). To match with medium resolution imaging spectrometer (MERIS) bands, in situ remote sensing reflectance was re-sampled to the bandwidth of 10 nm. The relationship between TSM and re-sampled R (rs) at 620 nm (MERIS band 6) and 665 nm (MERIS band 7) are obtained (R(2) = 0.748, RMSE = 1.697 mg L(?-?1), MRE = 8.785%, n = 13). Additionally, to map the spatial distribution of TSM in the PRE, MERIS level_1B data were calibrated using a multiple linear regression model based on in situ R (rs). Another dataset collected in the PRE in January 2004 was used to validate the two-band model and ...
2010-09-01
The metrology of the LHC project: what news?
Energy Technology Data Exchange (ETDEWEB)
The Large Hadron Collider (LHC), under construction at CERN, uses superconducting magnets operating at a temperature of 1.9 K to guide the circulating particles. A specific feature of the main magnets (dipoles and quadrupoles) is the two-in-one design with two magnetic channels in one common retaining structure. Indeed, the accelerator is made of two rings, mechanically linked, that have to be simultaneously aligned during the installation in the already existing LEP tunnel. The assembly tolerances of the LHC main magnets have been reconsidered to take into account the tight constraints on geometry. The dipoles are bent to follow closely the curvature of the circulating particles and to make a larger mechanical aperture available for the circulating particles. In order to minimise the geometrical errors the dipole assembly procedure is assisted by high precision survey measurements based on laser trackers. By this we hope to reduce to {+-} 1 mm ...
1999-07-01
Energy Technology Data Exchange (ETDEWEB)
Airborne fine particle sulfur data from the summer intensive of Project MOHAVE (Measurement of Haze and Visual Effects) was analyzed by the Receptor Model Applied to Patterns in Space (RMAPS) model, a novel multivariate receptor-oriented model that applies to secondary and primary species. The sulfur data from 17 sites were found to be well predicted by three spatial patterns interpreted as sources along the valley of the Colorado River (including the large Mohave coal-fired power plant, a smaller power plant and the city of Las Vegas); transport from sources located to the southwest; and transport from sources located to the southeast. The model was tested by using parameters derived from the 17-site data set to apportion sulfur for six sites that were not part of the original data set. The sulfur apportionment for these site sites was in agreement with the original apportionment and the physical interpretation of the spatial patterns given above. The effects of ...
1997-02-01
Monte Carlo simulation and dosimetric verification of radiotherapy beam modifiers
International Nuclear Information System (INIS)
Monte Carlo simulation of beam modifiers such as physical wedges and compensating filters has been performed with a rectilinear voxel geometry module. A modified version of the EGS4/DOSXYZ code has been developed for this purpose. The new implementations have been validated against the BEAM Monte Carlo code using its standard component modules (CMs) in several geometrical conditions. No significant disagreements were found within the statistical errors of 0.5% for photons and 2% for electrons. The clinical applicability and flexibility of the new version of the code has been assessed through an extensive verification versus dosimetric data. Both Varian multi-leaf collimator (MLC) wedges and standard wedges have been simulated and compared against experiments for 6 MV photon beams and different field sizes. Good agreement was found between calculated and measured depth doses and lateral dose profiles along both wedged and unwedged directions for ...
2001-11-01
Comparison and validation of two high-resolution weather forecast models at Frankfurt Airport
Energy Technology Data Exchange (ETDEWEB)
In recent years the 'Nowcasting Wake Vortex Impact Variables' model NOWVIV has been developed at the Deutsches Zentrum fuer Luft- und Raumfahrt, DLR, to forecast weather parameters in airport environments. The German Meteorological Service, DWD, employs his COSMO-DE model (COnsortium for Small scale Modelling-DEutschland) for operational forecasts in Germany. A systematic comparison of model output from NOWVIV and a derivate of COSMO-DE, named COSMO-FRA, is presented. Both models are centred at Frankfurt Airport with horizontal resolutions of 2.1 km and 2.8 km, respectively. In the DLR Project Wetter and Fliegen the COSMO-FRA model will replace the NOWVIV model and become a key component in the future rapid update cycle for adverse weather predictions at the airports of Frankfurt and Munich. The forecast vertical profiles of runway crosswind, head/tail wind, temperature, and turbulent kinetic energy (TKE) are validated against Wind and Temperature Radar (WTR/RASS) ...
2009-10-15
Energy Technology Data Exchange (ETDEWEB)
Existing test procedures for measuring and rating thermal performance require the determination of the angular response of collectors in order to account for nonnormal incident beam irradiance. Angular response measurements for four different types of collectors, each type tested by three different laboratories, are presented and analyzed. Substantial differences, both within and between laboratories, are reported for the same type collectors. An analysis of the measurement procedure shows that experimentally determined angular response parameters are subject to relatively large uncertainties. The problem results to a large extent from measuring collector efficiencies at non-normal incident angles where measurement uncertainty is of the same order of magnitude as the efficiency reduction attributable to these off-normal angles. Other factors ...
1982-11-01
Radon exhalation from and diffusion in concrete
International Nuclear Information System (INIS)
Cylindrical test pieces of concrete are used for measurements of "2"2"2Rn exhalation rates. Except one flat end surface of a test piece, other parts of its exteriority are covered with sealant. Radon atoms can escape only through its end surface from the interior into the outside air. This treatment makes the radon transport in the concrete one dimensional phenomena. The piece is put in an airtight container. Time variations of radon concentrations in the air of the container are measured with a plane multiwire-electrode ionization chamber. From this result, the radon areal exhalation rate is deduced for the piece. Exhalation rates are measured for four pieces with different length. Then, the diffusion coefficient is obtained for radon in the concrete as (5.0 #+-# 1.0) x 10"-"8m"2s"-"1 (a one-block method). A two-block method has been invented to obtain simultaneously values of three parameters: diffusion coefficient, ...
1990-12-01
Energy Technology Data Exchange (ETDEWEB)
The extent measurement error on CT colonography influences polyp categorisation according to established management guidelines is studied using twenty-eight observers of varying experience to classify polyps seen at CT colonography as either 'medium' (maximal diameter 6-9 mm) or 'large' (maximal diameter 10 mm or larger). Comparison was then made with the reference diameter obtained in each patient via colonoscopy. The Bland-Altman method was used to assess agreement between observer measurements and colonoscopy, and differences in measurement and categorisation was assessed using Kruskal-Wallis and Chi-squared test statistics respectively. Observer measurements on average underestimated the diameter of polyps when compared to the reference value, by approximately 2-3 mm, irrespective of observer experience. Ninety-five percent limits of agreement ...
2006-08-15
Energy Technology Data Exchange (ETDEWEB)
Bone formation and resorption have been measured in patients with idiopathic osteoporosis by histomorphometry of 7.5-mm trephine biopsies and in the whole body by 85Sr radiotracer methodology and calcium balances. The studies were synchronized and most were preceded by double in vivo tetracycline labeling. Correlations between histological and kinetic bone formation indices were better when better when based on the extent of double tetracycline labels than on measurements of osteoid by visible light microscopy. Correction of the kinetic data for long-term exchange, using 5 months' serial whole body counting of retained 85Sr, improved the fit of the kinetic to the histological data. A statistical analysis of the measurement uncertainties showed that the residual scatter in the best correlations (between exchange-corrected bone formation rates and double-labeled osteoid surface indices) could be attributed to ...
1987-12-01
Characterizing errors in digital elevation models and estimating the financial costs of accuracy
British Library Electronic Table of Contents (United Kingdom)
Digital topographic models are the foundation of more advanced modeling applications and ultimately inform planning and decision making in many fields. Despite this, the error associated with these models and derived attributes is commonly overlooked. Little attention has been given in the scientific literature to the benefits gained from having less error in a model or to the corresponding cost associated with reducing model error by choosing one product over another. To address these gaps in knowledge we evaluated the error associated with five digital elevation models (DEMs) and derived attributes of slope and aspect relative to the same attributes derived from LiDAR data. We also estimated the acquisition and processing costs per square kilometer of the five test models and the LiDAR m...
2010-01-01
Preliminary study of the application of natural olivine in Cenozoic dating
Energy Technology Data Exchange (ETDEWEB)
The study investigated the luminescence behaviour of natural olivine to discuss the potential for Cenozoic (quaternary) dating. The UV-blue thermoluminescence (TL) glow curves of irradiated olivines have a resolved peak at 190 deg. C and other peaks at higher temperature at lower dose levels, and broad signals around 275-310 and 375-400 deg. C at higher dose levels. The UV-blue TL increases with additional laboratory dose to {approx}1.6kGy within a plateau temperature region, suggesting the possibility of dosimetry and Cenozoic dating. Both infrared stimulated luminescence (IRSL) and blue light stimulated luminescence (BLSL) were detected from laboratory-irradiated olivines although the BLSL was weaker than the IRSL. Furthermore, post-BL IRSL was detected but post-IR BLSL was not observed. Therefore, IR stimulation is recommended for optically stimulated luminescence measurements with natural olivine. The growth of the IRSL ...
2006-08-15
European multicentre evaluation of the Super Aution SA-4220 urinalysis analyser.
A multicentre evaluation of the urine test strip analyser Super Aution-4220 was carried out in six laboratories. The analytical performance of the instrument with regard to imprecision, linearity, detection limit, drift, carry-over and method comparison was studied. Using the Aution stick 8 test strip the pH, glucose, protein, ketones, bilirubin, blood, urobilinogen and leukocyte esterase were analysed. Specific gravity measurements were performed by refractive index method. Within-run and between-run imprecision determined at three levels of analyte were good. No carry-over was observed. Obtained results were linear through all the described analytical range. No significant drift was detected. Method comparison with some quantitative methods was performed and showed a good correlation with most of the analytes. The study of interferences showed minor interferences by common therapeutic drugs with the measurement of some ...
1998-12-01
NPDGamma: A Measurement of the Parity-Violating Gamma Asymmetry A in n-p Capture
Energy Technology Data Exchange (ETDEWEB)
The NPDGamma Experiment measures the parity-violating correlation A{sub {Gamma}Y} between neutron spin and photon momentum in the reaction {rvec n} + p {yields} d + {gamma}. Knowledge of A{sub {Gamma}Y} and other parity-violating observables in few-body nuclear systems will provide constraints for a parameterized description of {Delta}S = 0 parity-violating phenomena free from complications of nuclear structure. The NPDGamma experiment uses a polarized cold pulsed neutron beam, a liquid parahydrogen target, and a cylindrical array of 48 CsI(Tl) scintillation detectors operated in current mode to search for the asymmetry. NPDGamma recently completed the first phase of the program to measure A{sub {Gamma}Y} at the Los Alamos Neutron Science Center with the preliminary result A{sub {Gamma}Y} = (-1.2 {+-} 2.1(stat.) {+-} 0.1(sys.)) x 10{sup -7}, reproducing the previous upper limit from a measurement at a reactor facility. We ...
2010-01-01
[Fast neutron cross section measurements]. Progress report
Energy Technology Data Exchange (ETDEWEB)
In this report, we outline the progress achieved in two distinct under the DOE-sponsored cross section project: the initial results obtained from the pulsed 14 MeV neutron facility, and a cooperative effort with Argonne National Laboratory in the measurement of fast neutron cross sections in yttrium. In the 14 MeV neutron laboratory, this year has seen the maturation of the project into one in which initial scattering measurements are now underway. We have improved the accelerator and ion source in several significant ways, so that neutron intensities have now been proven to be adequate for our series of elastic scattering angular distribution measurements outlined in our initial proposal of two years ago. We have successfully tested all components of the time-of-flight spectrometer and recorded initial neutron spectra from the ring targets that we have obtained for our first ...
1991-12-31
Bench-scale Kinetics Study of Mercury Reactions in FGD Liquors
Energy Technology Data Exchange (ETDEWEB)
This document is the final report for Cooperative Agreement DE-FC26-04NT42314, 'Kinetics Study of Mercury Reactions in FGD Liquors'. The project was co-funded by the U.S. DOE National Energy Technology Laboratory and EPRI. The objective of the project has been to determine the mechanisms and kinetics of the aqueous reactions of mercury absorbed by wet flue gas desulfurization (FGD) systems, and develop a kinetics model to predict mercury reactions in wet FGD systems. The model may be used to determine optimum wet FGD design and operating conditions to maximize mercury capture in wet FGD systems. Initially, a series of bench-top, liquid-phase reactor tests were conducted and mercury species concentrations were measured by UV/visible light spectroscopy to determine reactant and byproduct concentrations over time. Other measurement methods, such as atomic absorption, were used to measure ...
2008-03-31
Refractometry of organosilica microspheres
The refractive index of novel organosilica (nano/micro)material is determined using two methods. The first method is based on analysis of optical extinction efficiency of organosilica beads versus wavelength, which is obtained by a standard laboratory spectrometer. The second method relies on the measurable trapping potential of these beads in the focused light beam (laser tweezers). Polystyrene beads were used to test these methods, and the determined dispersion curves of refractive index values have been found accurate. The refractive index of organosilica beads has been determined to range from 1.60-1.51 over the wavelength range of 300-1100 nm.
2007-01-01
Radon in soil-air and in groundwater related to major geophysical events: A survey
Energy Technology Data Exchange (ETDEWEB)
The various technical aspects of radon concentration measurements in the ground or in the groundwater are reviewed. The emphasis is put on the most convenient techniques particularly suited for in situ monitoring in the field. Some attention is paid to the thoron problem. Historical and most recent findings in the field or earthquake related radon anomalies are presented and briefly discussed. A similar approach is made to rarer volcanic cases that have been documented up to now. A short discussion regarding the various models that intend to provide satisfactory explanations is presented, supported, whenever it is possible, by experimental laboratory results. Finally a glimpse on the possible and future application of the method to hydrogeology is given. (orig.).
1992-04-15
Midwest Superconductivity Consortium: 1994 Progress report
Energy Technology Data Exchange (ETDEWEB)
The mission of the Midwest Superconductivity Consortium, MISCON, is to advance the science and understanding of high {Tc} superconductivity. During the past year, 27 projects produced over 123 talks and 139 publications. Group activities and interactions involved 2 MISCON group meetings (held in August and January); with the second MISCON Workshop held in August; 13 external speakers; 79 collaborations (with universities, industry, Federal laboratories, and foreign research centers); and 48 exchanges of samples and/or measurements. Research achievements this past year focused on understanding the effects of processing phenomena on structure-property interrelationships and the fundamental nature of transport properties in high-temperature superconductors.
1995-01-01
Kinetics of salt concentration in heated crevices
International Nuclear Information System (INIS)
In PWR steam-generators, the crevice between tube and tube-support plate tends to fill with porous deposits during operation and acts as a concentration site for chemicals in the boiler water, which may lead to corrosion of the tube and tube-support-plate. The rate of concentration, the magnitude of the concentration factor and the rate of release of solute when conditions change are important parameters for devising strategies to minimize corrosion. Values of these parameters for salt concentration have therefore been measured in a laboratory simulation of the crevice and are used to formulate a model of the concentrating process.
1985-03-01
Hydrogen flame acceleration and transition to detonation
Energy Technology Data Exchange (ETDEWEB)
This paper describes the results obtained from two large experimental facilities built at Sandia National Laboratories in Albuquerque, NM. FLAME (Flame Acceleration Measurements and Experiments) is a large horizontal rectangular channel designed to study flame acceleration, transition to detonation, simulation of combustion in containment geometries, component heating, and other problems in hydrogen combustion relevant to reactor safety. The Heated Detonation Tube has been designed to study detonations in hydrogen-air-steam mixtures. Both facilities have been in operation for just over a year. 12 figures.
1984-01-01
Hydrogen flame acceleration and transition to detonation
International Nuclear Information System (INIS)
This paper describes the results obtained from two large experimental facilities built at Sandia National Laboratories in Albuquerque, NM. FLAME (Flame Acceleration Measurements and Experiments) is a large horizontal rectangular channel designed to study flame acceleration, transition to detonation, simulation of combustion in containment geometries, component heating, and other problems in hydrogen combustion relevant to reactor safety. The Heated Detonation Tube has been designed to study detonations in hydrogen-air-steam mixtures. Both facilities have been in operation for just over a year. 12 figures.
1984-10-23
International Nuclear Information System (INIS)
Hitherto in this laboratory, ionization coefficients alpha and attachment coefficients #eta# have been determined from Townsend's discharge experiments by a curve-fitting method. However, the method proved to be laborious, Formulae have been derived in this paper to give value of alpha and #eta# as a function of Isubo, Isub1 and Isub2 where Isubo is the photoelectric current at a gap setting d and Isub2 the current at another gap setting 2 d. The values of alpha and #eta# obtained give currents in agreement to within 3% in the best cases with the observed currents.
Development of high resolution imaging detectors for X-ray astronomy
Energy Technology Data Exchange (ETDEWEB)
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
1985-03-01
Development of high resolution imaging detectors for X-ray astronomy
International Nuclear Information System (INIS)
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
1985-01-01
Determining surface profile from sequential interference patterns from a long trace profiler
Energy Technology Data Exchange (ETDEWEB)
The Long Trace Profiler (Takacs et al.) is a slope-measuring instrument which was introduced several years ago. Development of this instrument continues at Lawrence Berkeley Laboratory in improving both hardware design and software algorithms for turning the raw interference data (a sequence of intensity patterns) into properly interpreted representations of surface slope and height. This report presents a mathematical model of the interference pattern and methods of extracting the slope and height profile from such patterns. 9 refs.
1991-07-01
Constraints on extra dimensions from cosmological and terrestrial measurements
If quantum fields exist in extra compact dimensions, they will give rise to a quantum vacuum or Casimir energy. That vacuum energy will manifest itself as a cosmological constant. The fact that supernova and cosmic microwave background data indicate that the cosmological constant is of the same order as the critical mass density to close the universe supplies a lower bound on the size of the extra dimensions. Recent laboratory constraints on deviations from Newton's law place an upper limit. The allowed region is so small as to suggest that either extra compact dimensions do not exist, or their number is about to be tightly constrained by experimental data.
2001-01-01
Constraints on Extra Dimensions from Cosmological and Terrestrial Measurements
If quantum fields exist in extra compact dimensions, they will give rise to a quantum vacuum or Casimir energy. That vacuum energy will manifest itself as a cosmological constant. The fact that supernova and cosmic microwave background data indicate that the cosmological constant is of the same order as the critical mass density to close the universe supplies a lower bound on the size of the extra dimensions. Recent laboratory constraints on deviations from Newton's law place an upper limit. The allowed region is so small as to suggest that either extra compact dimensions do not exist, or their properties are about to be tightly constrained by experimental data.
2000-01-01
Calculations of the self-amplified spontaneous emission performance of a free-electron laser.
Energy Technology Data Exchange (ETDEWEB)
The linear integral equation based computer code (RON: Roger Oleg Nikolai), which was recently developed at Argonne National Laboratory, was used to calculate the self-amplified spontaneous emission (SASE) performance of the free-electron laser (FEL) being built at Argonne. Signal growth calculations under different conditions are used for estimating tolerances of actual design parameters. The radiation characteristics are discussed, and calculations using an ideal undulator magnetic field and a real measured magnetic field will be compared and discussed.
1999-04-20
Application of the GEM shutdown device to the FFTF reactor
Energy Technology Data Exchange (ETDEWEB)
A novel device called the gas expansion model (GEM) is being developed at the Hanford Engineering Development Laboratory for testing in the 400-MW(th) fast flux test facility (FFTF) reactor. Incorporation of the GEM into liquid-metal reactor designs is intended to measurably contribute to the achievement of inherent safety, by allowing the reactor to passively shut down even in the extremely remote (hypothetical) event of an unprotected (no scram) loss-of-flow accident. The purpose of this paper is to describe the GEM and present predictive analyses of the effectiveness of the device during unprotected loss-of-flow experiments in the FFTF.
1986-01-01
Application of the GEM shutdown device to the FFTF reactor
International Nuclear Information System (INIS)
A novel device called the gas expansion model (GEM) is being developed at the Hanford Engineering Development Laboratory for testing in the 400-MW(th) fast flux test facility (FFTF) reactor. Incorporation of the GEM into liquid-metal reactor designs is intended to measurably contribute to the achievement of inherent safety, by allowing the reactor to passively shut down even in the extremely remote (hypothetical) event of an unprotected (no scram) loss-of-flow accident. The purpose of this paper is to describe the GEM and present predictive analyses of the effectiveness of the device during unprotected loss-of-flow experiments in the FFTF.
1986-11-16
International Nuclear Information System (INIS)
During one year more than 40,000 items of information on radiation exposure of personnel involved in the handling of radiation sources and more than 5,000,000 items on irradiation of other people are collected in the authors' laboratory. Considerable progress in assessment of mean annual gonad dose of genetically sifnificant dose was attained by means of an algorithm for a personal computer. This simple and inexpensive system has led to a higher accuracy in the application of protective measures. (author).
1985-10-22
A study on diagnostic techniques of pump operating condition
Energy Technology Data Exchange (ETDEWEB)
The scope and contents investigate and reviewed are as follows : establishment of study plan and references survey, review of related problems and inservice test standards of safety injection pump in use nuclear power plant, review of the study results in laboratory, the theoretical investigation of temperature rise according to mini-flow rate of pump, mini-flow rate working characteristics of high and low pressure injection pumps at nuclear power plants, setup of testing equipment for measuring ampere, discharge pressure and vibration, selection and behaviors analysis of major parameters concerning pump degradation.
1998-03-15
A study of aging effects in gas proportional detectors at the BAC calorimeter of the ZEUS experiment
Energy Technology Data Exchange (ETDEWEB)
The multicell proportional chambers at the backing calorimeter of the ZEUS experiment at the storage ring HERA are supplied with a gas mixture of Ar/CO[sub 2] by an open gas system. Flow proportional counters with the build-up [sup 55]Fe sources are used as gas system monitoring detectors. The ZEUS experiment is planned to collect data for about 10 years. Therefore, the lifetime of the Ar/CO[sub 2] mixture should be known. In this paper, the results of laboratory tests and preliminary measurements of the aging effects for monitoring counters are presented. ((orig.))
1994-09-01
Improving the PSA quality in the human reliability analysis of pre-accident human errors
Energy Technology Data Exchange (ETDEWEB)
This paper describes the activities for improving the Probabilistic Safety Assessment (PSA) quality in the human reliability analysis (HRA) of the pre-accident human errors for the Korea Standard Nuclear Power Plant (KSNP). We evaluate the HRA results of the PSA for the KSNP and identify the items to be improved using the ASME PRA Standard. Evaluation results show that the ratio of items to be improved for pre-accident human errors is relatively high when compared with the ratio of those for post-accident human errors. They also show that more than 50% of the items to be improved for pre-accident human errors are related to the identification and screening analysis for them. In this paper, we develop the modeling guidelines for pre-accident human errors and apply them to the auxiliary feedwater system of the KSNP. Application results show that more than 50% of the items to be ...
2004-07-01
Improving the PSA quality in the human reliability analysis of pre-accident human errors
International Nuclear Information System (INIS)
This paper describes the activities for improving the Probabilistic Safety Assessment (PSA) quality in the human reliability analysis (HRA) of the pre-accident human errors for the Korea Standard Nuclear Power Plant (KSNP). We evaluate the HRA results of the PSA for the KSNP and identify the items to be improved using the ASME PRA Standard. Evaluation results show that the ratio of items to be improved for pre-accident human errors is relatively high when compared with the ratio of those for post-accident human errors. They also show that more than 50% of the items to be improved for pre-accident human errors are related to the identification and screening analysis for them. In this paper, we develop the modeling guidelines for pre-accident human errors and apply them to the auxiliary feedwater system of the KSNP. Application results show that more than 50% of the items to be ...
2004-06-06
A Statistical Treatment of the Gamma-Ray Burst "No Host Galaxy" Problem; 1, Methodology
If gamma-ray bursts originate in galaxies at cosmological distances, the host galaxy should be detected if a burst error box is searched deep enough; are the host galaxies present? We present and implement a statistical methodology which evaluates whether the observed galaxy detections in a burst's error box are consistent with the presence of the host galaxy, or whether all the detections can be attributed to unrelated background galaxies. This methodology requires the model-dependent distribution of host galaxy fluxes. While our methodology was derived for galaxies in burst error boxes, it can be applied to other candidate host objects (e.g., active galaxies) and to other types of error boxes. As examples, we apply this methodology to two published studies of burst error boxes. We find that the nine error boxes observed by Larson and McLean (1997) are too ...
1997-01-01
Mathematical modeling of x-probe eddy current array coils used in tube inspection
Energy Technology Data Exchange (ETDEWEB)
This paper presents a mathematical model that calculates eddy current signals from laterally spaced transmit-receive pancake coils. This model was validated by comparing calculations with laboratory measurements and it has been applied to evaluating design variations in X-Probe eddy current array coils. This model was used to quantify detection capabilities of probe designs with different numbers of coils. The current standard X-Probe design for 13 mm (0.5 inch) diameter steam generator tubes uses 3 rows of coils with 8 coils per row. This design is commonly referred to as the '8 coil X-Probe'. A significant improvement in detection capability was predicted for an X-Probe with 12 coils per row (called the '12 coil X-Probe') detecting short circumferential crack-like flaws. Based on these calculations, a prototype 12 coil X-Probe was constructed and used in laboratory ...
2004-11-15
On-orbit spectral calibration of hyperspectral imaging data is a key step for quantitatively analyzing them. Like the atmospheric correction, accurate spectral calibration is very necessary for improved studies of land or ocean surface properties. Based on the previous literatures, a new method which coupled an optimization algorithm was developed to simultaneously retrieve the central wavelength and the full width at half maximum (FWHM) of the hyperspectral sensor without needing the in situ reflectance spectra. Firstly, the Hyperion data set simulated using MODTRAN4 with the Hyperion spectral specification was used to test the new method, and the results indicated that the maximum error was less than 0.1 and 0.7 nm for central wavelength and FWHM respectively when the spectral shift is 5 nm. Then the algorithm was applied to the Hyperion data acquired on May 20, 2008 over Heihe River Basin and it was iteratively performed for each detector of the two ...
2010-10-01
Well log evaluation of natural gas hydrates
Energy Technology Data Exchange (ETDEWEB)
Gas hydrates are crystalline substances composed of water and gas, in which a solid-water-lattice accommodates gas molecules in a cage-like structure. Gas hydrates are globally widespread in permafrost regions and beneath the sea in sediment of outer continental margins. While methane, propane, and other gases can be included in the clathrate structure, methane hydrates appear to be the most common in nature. The amount of methane sequestered in gas hydrates is probably enormous, but estimates are speculative and range over three orders of magnitude from about 100,000 to 270,000,000 trillion cubic feet. The amount of gas in the hydrate reservoirs of the world greedy exceeds the volume of known conventional gas reserves. Gas hydrates also represent a significant drilling and production hazard. A fundamental question linking gas hydrate resource and hazard issues is: What is the volume of gas hydrates and included gas within a given gas hydrate occurrence Most published gas hydrate ...
1992-10-01
Well log evaluation of natural gas hydrates
Energy Technology Data Exchange (ETDEWEB)
Gas hydrates are crystalline substances composed of water and gas, in which a solid-water-lattice accommodates gas molecules in a cage-like structure. Gas hydrates are globally widespread in permafrost regions and beneath the sea in sediment of outer continental margins. While methane, propane, and other gases can be included in the clathrate structure, methane hydrates appear to be the most common in nature. The amount of methane sequestered in gas hydrates is probably enormous, but estimates are speculative and range over three orders of magnitude from about 100,000 to 270,000,000 trillion cubic feet. The amount of gas in the hydrate reservoirs of the world greedy exceeds the volume of known conventional gas reserves. Gas hydrates also represent a significant drilling and production hazard. A fundamental question linking gas hydrate resource and hazard issues is: What is the volume of gas hydrates and included gas within a given gas hydrate occurrence? Most published gas hydrate ...
1992-10-01
Energy Technology Data Exchange (ETDEWEB)
A technique has been developed at the Idaho National Engineering Laboratory to sum high resolution gamma-ray pulse spectra from systems with multiple Ge detectors. Lockheed Martin Idaho Technologies Company operates a multi-detector spectrometer configuration at the Stored Waste Examination Pilot Plant facility which is used to characterize the radio nuclide contents in waste drums destined for shipment to Waste Isolation Pilot Plant. This summing technique was developed to increase the sensitivity of the system, reduce the count times required to properly quantify the radionuclides and provide a more consistent methodology for combining data collected from multiple detectors. In spectrometer systems with multiple detectors looking at non homogenous waste forms it is often difficult to combine individual spectrum analysis results from each detector to obtain a meaningful result for the total waste container. This is particularly true when the counting statistics in ...
1997-05-01
Vibration signature analysis of AFM images
Energy Technology Data Exchange (ETDEWEB)
Vibration signature analysis has been commonly used for the machine condition monitoring and the control of errors. However, it has been rarely employed for the analysis of the precision instruments such as an atomic force microscope (AFM). In this work, an AFM was used to collect vibration data from a sample positioning stage under different suspension and support conditions. Certain structural characteristics of the sample positioning stage show up as a result of the vibration signature analysis of the surface height images measured using an AFM. It is important to understand these vibration characteristics in order to reduce vibrational uncertainty, improve the damping and structural design, and to eliminate the imaging imperfections. The choice of method applied for vibration analysis may affect the results. Two methods, the data dependent systems (DDS) analysis and the Welch`s periodogram averaging method were investigated for application ...
1995-12-31
The Eddy Experiment: accurate GNSS-R ocean altimetry from low altitude aircraft
During the Eddy Experiment, two synchronous GPS receivers were flown at 1 km altitude to collect L1 signals and their reflections from the sea surface for assessment of altimetric precision and accuracy. Wind speed (U10) was around 10 m/s, and SWH up to 2 m. A geophysical parametric waveform model was used for retracking and estimation of the lapse between the direct and reflected signals with a 1-second precision of 3 m. The lapse was used to estimate the SSH along the track using a differential model. The RMS error of the 20 km averaged GNSS-R absolute altimetric solution with respect to Jason-1 SSH and a GPS buoy measurement was of 10 cm, with a 2 cm mean difference. Multipath and retracking parameter sensitivity due to the low altitude are suspected to have degraded accuracy. This result provides an important milestone on the road to a GNSS-R mesoscale altimetry space mission.
2004-01-01
International Nuclear Information System (INIS)
This work improves the reliability and accuracy in the reconstruction of the total isotope activity content in heterogeneous nuclear waste drums containing point sources. The method is based on #chi#"2-fits of the angular dependent count rate distribution measured during a drum rotation in segmented gamma scanning. A new description of the analytical calculation of the angular count rate distribution is introduced based on a more precise model of the collimated detector. The new description is validated and compared to the old description using MCNP5 simulations of angular dependent count rate distributions of Co-60 and Cs-137 point sources. It is shown that the new model describes the angular dependent count rate distribution significantly more accurate compared to the old model. Hence, the reconstruction of the activity is more accurate and the errors are considerably reduced that lead to more reliable results. Furthermore, the results are ...
2011-06-01
Orbital roulette: a new method of gravity estimation from observed motions
The traditional way of estimating the gravitational field from observed motions of test objects is based on the virial relation between their kinetic and potential energy. We find a more efficient method. It is based on the natural presumption that the objects are observed at a random moment of time and therefore have random orbital time phases. The proposed estimator, which we call "orbital roulette", checks the randomness of the phases. The method has the following advantages: (1) It estimates accurately Keplerian (point-mass) potentials as well as non-Keplerian potentials where the unknown gravitating mass is distributed in space. (2) It is a complete statistical estimator: it checks a trial potential and accepts it or rules it out with a certain significance level; the best-fit measurement is thus supplemented with error bars at any confidence level. (3) It needs no a priori assumptions about the distribution of orbital parameters of the ...
2004-01-01
Mercury modeling for PWSCC length sizing. [Primary water stress corrosion cracking
This report describes the results of EPRI Program S404-28, titled Experimental Modeling of Eddy Current Response'', conducted by the Westinghouse Science and Technology Center (STC). The Westinghouse STC demonstrates that its mercury modeling technique provides an unique bridge between steam generator eddy current field inspection conditions and predictions obtained using recently developed analytical models. The mercury modeling technique was used systematically to explore factors which contribute to primary water stress corrosion cracking (PWSCC) sizing inaccuracy, including probe design, coil excitation frequency, crack length, and crack morphology. Two new proposed techniques for inverting crack lengths from eddy current data are compared with the technique commonly used in field data analysis for PWSCC. The performance of uniform field eddy current probes is compared with the performance of pancake coil probe designs, and an assessment of the advantages and ...
1992-08-01
Mercury modeling for PWSCC length sizing. [Primary water stress corrosion cracking
Energy Technology Data Exchange (ETDEWEB)
This report describes the results of EPRI Program S404-28, titled Experimental Modeling of Eddy Current Response'', conducted by the Westinghouse Science and Technology Center (STC). The Westinghouse STC demonstrates that its mercury modeling technique provides an unique bridge between steam generator eddy current field inspection conditions and predictions obtained using recently developed analytical models. The mercury modeling technique was used systematically to explore factors which contribute to primary water stress corrosion cracking (PWSCC) sizing inaccuracy, including probe design, coil excitation frequency, crack length, and crack morphology. Two new proposed techniques for inverting crack lengths from eddy current data are compared with the technique commonly used in field data analysis for PWSCC. The performance of uniform field eddy current probes is compared with the performance of pancake coil probe designs, and an assessment of the advantages and ...
1992-08-01
International Nuclear Information System (INIS)
Inner ring structures are observed in about one quarter of all lenticular or spiral galaxies. Statistics of the relative frequencies of the pure ring (r) and broken ring (rs) varieties in the Second Reference Catalogue (RC2) among the different families (A, AB, B) of lenticular (L) and spiral (S) galaxies at different stages (T) along the revised Hubble sequence are presented; selection effects dependent on classification weight, apparent diameter and axis ratio are discussed. Comparisons of ring diameters D/sub r/ listed in the (First) Reference Catalogue (RC1) with independent measurements of 43 barred systems by Kormendy show good systematic agreement with a standard deviation sigma_1_2(D/sub r/) = 0'.10 and individual relative mean errors sigma(D/sub r/)/ < D/sub r/ > approx. = 5%. Axis ratios are also in good agreement with sigma_1_2(b/a) = 0.06. Comparisons of axis ratios of rings and parent galaxies show systematic trends dependent ...
International Nuclear Information System (INIS)
State-of-the-art approaches for the calculation of gamma heating in LMFBR core, blanket and reflector regions have been evaluated, with particular emphasis on coupled neutron-gamma methods/cross section sets. The major source of calculational error was found to be the apparent failure to impose a mass-energy balance on total gamma energy yield from neutron capture and other interactions in the preparation of representative neutron-gamma cross section sets. The applicability of many simplifying assumptions was demonstrated, including: volume-weighted homogenization, insensitivity to the shape of the gamma-source-spectrum, gamma energy deposition equal to gamma energy source more than 10 cm inside large zones of uniform composition, and the negligible effect of bremsstrahlung. A simple one-group method was developed to permit rapid, accurate estimation of the large (factor of 2) changes in the gamma energy deposition-to-source ratio possible near region interfaces. ...
1976-01-01
Extreme sensitivity of some intestinal crypt cells to X and #gamma# irradiation
International Nuclear Information System (INIS)
Reference is made to Cheng and Leblond (Amer. J. Anat.; 141:537 (1974)) who used tritiated thymidine to kill cells synthesising DNA in the crypts of the small intestine. Amongst their findings was that very low doses caused measurable cell killing and that the killing was not random throughout the crypt but occurred selectively at the crypt base where stem cells are presumably located. It is here reported that the presence of hypersensitive cells at the base of the crypts can be demonstrated after whole-body X- or gamma-irradiation, and the time sequence for the production and loss of the killed cells is described together with their dose-response relationship. The studies were conducted on mice. The data were expressed as surviving rather than killed cells, and it was established that the crypt are amongst the most sensitive of mammalian cells. The mechanism by which these sensitive cells are killed is not known, but DNA damage can be detected. The vital stem ...
1977-10-01
Energy Technology Data Exchange (ETDEWEB)
As a series of experimental determinations of the thermal diffusivity of molten alkali halides, this paper describes measurements on five molten alkali metal chlorides (LiCl, NaCl, KCl, RbCl, and CsCl) in the temperature range up to 1440 K by the forced Rayleigh scattering method. K[sub 2]Cr[sub 2]O[sub 7] is employed as a dye substance to color the transparent molten salts. In comparison with the present results converted into thermal conductivity, most of the previous experimental data obtained by steady-state methods show larger values, up to about five times, which may be due to the systematic error caused by the presence of convection and radiation. It is found that the thermal conductivity of these series of molten alkali metal chlorides decreases with increasing molecular weight, and their temperature coefficients are weakly negative. 24 refs., 9 figs., 6 tabs.
1992-07-01
Energy Technology Data Exchange (ETDEWEB)
The present paper explains the curve-fitting method developed as a method to estimate the geothermal equilibrium forming temperature. In the present method, that temperature is estimated by obtaining, by non-linear lest square, the model parameter to minimize the sum of remainders squared between the temperature actually measured after a lapse of certain time from the stoppage of mud water circulation and that calculated on the basis of Middleton model, mathematical model of temperature equilibrium well. In the Horner's plotting method currently in general use, temperature recovery data during a long period of about 120h are required for estimating the geothermal equilibrium forming temperature. However in the curve-fitting method, it is confirmed from the actual well data that the well recovery temperature is estimable from three logging data during 24h after the stoppage of mud water circulation within the largest error of 5%, and ...
1994-05-01
Energy Technology Data Exchange (ETDEWEB)
To significantly improve the simulation of climate by general circulation models (GCMs), systematic errors in representations of relevant processes must first be identified, and then reduced. This endeavor demands that the GCM parameterizations of unresolved processes, in particular, should be tested over a wide range of time scales, not just in climate simulations. Thus, a numerical weather prediction (NWP) methodology for evaluating model parameterizations and gaining insights into their behavior may prove useful, provided that suitable adaptations are made for implementation in climate GCMs. This method entails the generation of short-range weather forecasts by a realistically initialized climate GCM, and the application of six-hourly NWP analyses and observations of parameterized variables to evaluate these forecasts. The behavior of the parameterizations in such a weather-forecasting framework can provide insights on how these schemes might be improved, and ...
2004-05-06
Distributed Beamforming in Wireless Multiuser Relay-Interference Networks with Quantized Feedback
We study quantized beamforming in wireless amplify-and-forward relay-interference networks with any number of transmitters, relays, and receivers. We design the quantizer of the channel state information to minimize the probability that at least one receiver incorrectly decodes its desired symbol(s). Correspondingly, we introduce a generalized diversity measure that encapsulates the conventional one as the first-order diversity. Additionally, it incorporates the second-order diversity, which is concerned with the transmitter power dependent logarithmic terms that appear in the error rate expression. First, we show that, regardless of the quantizer and the amount of feedback that is used, the relay-interference network suffers a second-order diversity loss compared to interference-free networks. Then, two different quantization schemes are studied: First, using a global quantizer, we show that a simple relay selection scheme can achieve maximal ...
2010-01-01
An accurate high-speed single-electron quantum dot pump
International Nuclear Information System (INIS)
Using standard microfabrication techniques, it is now possible to construct devices that appear to reliably manipulate electrons one at a time. These devices have potential use as building blocks in quantum computing devices, or as a standard of electrical current derived only from a frequency and the fundamental charge. To date, the error rate in semiconductor 'tuneable-barrier' pump devices, those which show most promise for high-frequency operation, have not been tested in detail. We present high-accuracy measurements of the current from an etched GaAs quantum dot pump, operated at zero source-drain bias voltage with a single ac-modulated gate at 340 MHz driving the pump cycle. By comparison with a reference current derived from primary standards, we show that the electron transfer accuracy is better than 15 parts per million. High-resolution studies of the dependence of the pump current on the quantum dot tuning parameters also reveal ...
2010-07-01
All-atom molecular dynamics simulations using orientational constraints from anisotropic NMR samples
Orientational constraints obtained from solid state NMR experiments on anisotropic samples are used here in molecular dynamics (MD) simulations for determining the structure and dynamics of several different membrane-bound molecules. The new MD technique is based on the inclusion of orientation dependent pseudo-forces in the COSMOS-NMR force field. These forces drive molecular rotations and re-orientations in the simulation, such that the motional time-averages of the tensorial NMR properties approach the experimentally measured parameters. The orientational-constraint-driven MD simulations are universally applicable to all NMR interaction tensors, such as chemical shifts, dipolar couplings and quadrupolar interactions. The strategy does not depend on the initial choice of coordinates, and is in principle suitable for any flexible molecule. To test the method on three systems of increasing complexity, we used as constraints some deuterium quadrupolar couplings from ...
2007-03-03
All-atom molecular dynamics simulations using orientational constraints from anisotropic NMR samples
Energy Technology Data Exchange (ETDEWEB)
Orientational constraints obtained from solid state NMR experiments on anisotropic samples are used here in molecular dynamics (MD) simulations for determining the structure and dynamics of several different membrane-bound molecules. The new MD technique is based on the inclusion of orientation dependent pseudo-forces in the COSMOS-NMR force field. These forces drive molecular rotations and re-orientations in the simulation, such that the motional time-averages of the tensorial NMR properties approach the experimentally measured parameters. The orientational-constraint-driven MD simulations are universally applicable to all NMR interaction tensors, such as chemical shifts, dipolar couplings and quadrupolar interactions. The strategy does not depend on the initial choice of coordinates, and is in principle suitable for any flexible molecule. To test the method on three systems of increasing complexity, we used as constraints some deuterium quadrupolar couplings from ...
2007-05-15
All-atom molecular dynamics simulations using orientational constraints from anisotropic NMR samples
International Nuclear Information System (INIS)
Orientational constraints obtained from solid state NMR experiments on anisotropic samples are used here in molecular dynamics (MD) simulations for determining the structure and dynamics of several different membrane-bound molecules. The new MD technique is based on the inclusion of orientation dependent pseudo-forces in the COSMOS-NMR force field. These forces drive molecular rotations and re-orientations in the simulation, such that the motional time-averages of the tensorial NMR properties approach the experimentally measured parameters. The orientational-constraint-driven MD simulations are universally applicable to all NMR interaction tensors, such as chemical shifts, dipolar couplings and quadrupolar interactions. The strategy does not depend on the initial choice of coordinates, and is in principle suitable for any flexible molecule. To test the method on three systems of increasing complexity, we used as constraints some deuterium quadrupolar couplings from ...
2007-05-01
Recent data from CREAM seem to confirm early suggestions that primary cosmic ray spectra at few TeV/nucleon are harder than in the 10-100 GeV range. Also, helium and heavier nuclei spectra appear systematically harder than the proton fluxes at corresponding energies. We note here that if the measurements reflect intrinsic features in the interstellar fluxes, appreciable modifications are expected in the sub-TeV range for the secondary yields, such as antiprotons and diffuse gamma-rays. Presently, this effect represents a systematic error in the extraction of astrophysical parameters as well as for background estimates for indirect dark matter searches. We find that the spectral modifications are appreciable above 100 GeV, and can be responsible for ~30% effects for antiprotons at energies close to 1 TeV or for gamma's at energies close to 300 GeV, compared to currently considered predictions based on simple extrapolation of input fluxes from ...
2010-01-01
Reliability of indices of neuromuscular leg performance in end-stage renal failure.
The purpose of this study was to examine the day-to-day reproducibility and single measurement reliability of peak force, time to half peak force and rate of force development indices of knee extension neuromuscular performance in patients with end-stage renal failure. Eleven self-selected patients (6 men, 5 women) receiving maintenance dialysis (dialysis history 67 +/- 42.8 month) completed 3 inter-day assessment sessions. Each comprised a standardized warm-up and 3 intermittent static maximal voluntary actions of the knee extensors of the preferred limb (45 degrees knee flexion angle [0 degrees = full knee extension]) using a specially-constructed dynamometer. Repeated measures ANOVA of coefficient of variation scores revealed significant differences between indices in their reproducibility across day-to-day trials. Post-hoc comparisons of group mean scores suggested that peak force (6.6 +/- 3.0%) offers significantly greater ...
2002-11-01
Higgs particles in the standard model and supersymmetric theories
International Nuclear Information System (INIS)
This thesis presents a theoretical analysis of the properties of the Higgs bosons in the standard model (SM) and the minimal supersymmetric extension (MSSM), which can be investigated at the LHC and e"+e"- linear colliders. The final goal is the reconstruction of the Higgs potential and thus the verification of the Higgs mechanism. MSSM Higgs boson production processes at future #gamma##gamma# colliders are calculated in several decay channels. Heavy scalar and pseudoscalar Higgs bosons can be discovered in the bb final state in the investigated mass range 200 to 800 GeV for moderate and large values of tan#beta#. The #tau#"+#tau#"- channel provides a heavy Higgs boson discovery potential for large values of tan#beta#. Several mechanisms that can be exploited at e"+e"- linear colliders for the measurement of the lifetime of a SM Higgs boson in the intermediate mass range are analysed. In the WW mode, the lifetime of Higgs scalars with masses below #propor to#160 ...
Cerenkov ring imaging and spectroscopy of charged KSTAR interactions at 11 GeV/c
Energy Technology Data Exchange (ETDEWEB)
The physics and technology of this new Cerenkov detector are discussed, including materials studies, construction techniques, and resolution measurements. Sources of resolution error are individually identified and measured where possible. The results of all studied indicate that the measurement resolution is understood. This work has led to the adoption of a large scale ring imaging detector as part of a new high energy physics spectrometer, the SLD, at the Stanford Linear Accelerator Center. Results from an amplitude analysis of strange meson final states in K/sup /minus//p ..-->.. /ovr K/sub 0//..pi../sup /minus//p interactions are presented. The data derive from a 4 event/nb exposure of the LASS (large Aperture Superconducting Solenoid) spectrometer to an 11 GeV/c K/sup /minus// beam. The data sample consists of /approximately/100,000 vents distributed over the Dalitz plot of the channel. The ...
1988-11-01
Use of a point-of-care beta-hydroxybutyrate sensor for detection of ketonemia in dogs.
The urine test strip is the most common test used to detect ketones in veterinary patients, but it can underestimate the degree of ketonuria and hence, ketonemia. Additionally, adequate urine samples for analysis may be difficult to obtain from dehydrated animals. The standard method used to detect and monitor ketonemia in human medicine is measurement of serum or whole blood beta-hydroxybutyrate (?HOB). A point-of-care (POC) analyzer has been validated for this purpose in humans. This study compared the accuracy of the POC device to an enzymatic reaction laboratory method for measurement of ?HOB in dogs. Although the POC sensor tended to overestimate ?HOB concentrations, there was good correlation (R(2) = 0.96) and good agreement between the 2 methods with a bias +/- precision of 0.0860 +/- 0.3410 mmol/L ?HOB. The POC ?HOB sensor can be useful for assessing ketonemia in dogs. PMID:21119867
2010-09-01
Unitary constraints on Deeply Virtual Compton Scattering
Energy Technology Data Exchange (ETDEWEB)
At moderately low momentum transfer ($-t$ up to 1 GeV$^2$) the coupling to the vector meson production channels gives the dominant contribution to real Compton and deeply virtual Compton scattering (DVCS). Starting from a Regge Pole approach that successfully describes vector meson production, the singular part of the corresponding box diagrams (where the intermediate vector meson-baryon pair propagates on-shell) is evaluated without any further assumptions (unitarity). Such a treatment explains not only the unexpectedly large DVCS unpolarized cross section that has been recently measured at Jefferson Laboratory (JLab), but also all the beam spin and charge asymmetries that has been measured at JLab and Hermes, without explicit need of Generalized Parton Distributions (GPD). The issue of the relationship between the two approaches is addressed.
2007-11-01
British Library Electronic Table of Contents (United Kingdom)
Purpose Ultraviolet-B (UV-B) radiation can cause phototoxic macular injuries in young people who have been sunbathing but not sungazing and in welders. Welders have a reportedly increased risk of uveal melanoma. We analyze phakic and pseudophakic risks for solar and welding arc UV-B exposure. Design Optical radiation measurement, analysis, and perspective. Methods Spectral transmittances were measured for UV-transmitting, UV-blocking, and blue-blocking intraocular lenses (IOLs). The photoprotective performances of crystalline and intraocular lenses were analyzed using relevant epidemiologic and laboratory data and action spectra for acute retinal phototoxicity and melanoma photocarcinogenesis. Results Crystalline lens UV-B retinal protection is deficient in children and young adults, incre...
2010-01-01
Surface characteristics and overlaying properties of flat-pressed wood plastic composites
British Library Electronic Table of Contents (United Kingdom)
This study evaluated surface characteristics and overlaying properties of wood plastic composite (WPC) panels made from dry-blended rubber wood fiber-polypropylene (PP) powder formulations using a conventional flat-press process under laboratory conditions. Three levels of rubberwood fibers (Hevea brasiliensis), 40%, 50%, and 60%, based on the composition by weight, were mixed with the PP powder without and with 3% (based on weight) maleic anhydride grafted PP (MAPP) as a coupling agent. Contact angle measurements on the WPC samples were performed using a goniometer connected with a digital camera which collected one image per second. Roughness measurements, average roughness (R a), mean peak-to-valley height (R z), and maximum roughness (R y), were taken from the sanded samples along and ...
2011-01-01
Sandia National Laboratories has erected a research oriented, 34- meter diameter, Darrieus vertical axis wind turbine near Bushland, Texas. This machine, designated the Sandia 34-m VAWT Test Bed, is equipped with a large array of strain gauges that have been placed at critical positions about the blades. This manuscript details a series of four-point bend experiments that were conducted to validate the output of the blade strain gauge circuits. The output of a particular gauge circuit is validated by comparing its output to equivalent gauge circuits (in this stress state) and to theoretical predictions. With only a few exceptions, the difference between measured and predicted strain values for a gauge circuit was found to be of the order of the estimated repeatability for the measurement system.
1988-08-01
Energy Technology Data Exchange (ETDEWEB)
The release of {sup 222}Radon to the atmosphere is controlled by the rate of its gas transport through earthen materials. Of the many soil-related parameters, radon diffusion coefficient is the key parameter that characterizes this transport. We compared the radon diffusion coefficients measured at the laboratories for the UMTRA Project with simple empirical correlations developed by others. The empirical correlations predict the radon diffusion coefficient based on the fraction of moisture saturation and porosity. One of the more recent correlations agrees reasonably well with the measurements. In addition, by using a series of correlation curves, we studied the empirical relationships of the. radon diffusion coefficient with the saturated hydraulic conductivity, the fines content, and the moisture saturation in soil. The results reveal that a reliable determination of the long-term moisture and porosity is essential in ...
1994-01-24
International Nuclear Information System (INIS)
The main points of quality control methods and technique of environmental radiological baseline study of Guangdong Daya Bay Nuclear Power Station are reported. Results of intercalibration of international and inland laboratories are given. The random chosen samples are checked and compared with two measurement methods. The data obtained in Daya Bay environment are put to the correlation statistics test using the linear regression analysis method between the correlative items such as "4"0K activity by gamma spectrum measurement and potassium content by chemical analysis, total #alpha#(#beta#) activity and nuclide content, as well as environmental gamma radiation dose rate and TLD accumulation dose. The data of Daya Bay environmental radioactivity baseline level show good concordance and reliability.
British Library Electronic Table of Contents (United Kingdom)
SUMMARY Spontaneous potentials associated with volcanic activity are often interpreted by means of the electrokinetic potential, which is usually positive in the flow direction (i.e. Zeta potential of the rock is negative). The water-rock interactions in hydrothermal zones alter the primary minerals leading to the formation of secondary minerals. This work addresses the study of calcite precipitation in a sand composed of 98 per cent quartz and 2 per cent calcite using streaming potential measurements. The precipitation of calcite as a secondary mineral phase, inferred by high calcite saturation indices and by a fall in permeability, has a significant effect on the electrokinetic behaviour, leading to a significant reduction in the Zeta potential (in absolute value) and even a change in si...
2006-01-01
International Nuclear Information System (INIS)
By the department Radio-ecology of the Laboratory for Radiation Research, in the period 1981 up to 1989 inclusive, the transfer has been studied, from soil to plant, of a number of important activation and fission products, originating in the nuclear-power production in nuclear power plants. The purpose of this study was twofold: on the one side the quantification of this transfer for various agrarian systems and on the other side to find out in how far, after an accidental contamination, certain agriculture activities can influence essentially the transfer and subsequently the radiation burden for the population. Emphasis lay, the last years, in particular upon this second aspect. The results of this study form essential basic data for diffusion models for radioactive materials which, in turn, are important in estimating the effects of measures. (author). 6 refs.; 4 figs.
Measurement of beta-decay half-lives of short-lived nuclei with Spectrum Multi-Scaler (SMS)
Energy Technology Data Exchange (ETDEWEB)
The half-lives of short-lived nuclei produced by 14 MeV or thermal neutron bombardments were measured with a Ge detector, a Spectrum Multi-Scaler (Laboratory Equipment Corporation SMS-48) and a High-Rate Spectroscopy Amplifier (EG and G ORTEC Model 973) in the multi-scaling mode. The corrections for pile-up and dead-time losses were performed by applying source and pulser methods. The half-lives of {sup 91m}Mo, {sup 97m}Nb, {sup 138}Cs, {sup 139}Ba, {sup 174}Tm and {sup 203m}Pb were determined with accuracy of 0.22-0.6% and the accuracy has been much improved. (author)
1996-03-01
Indoor climate seminar; Sisaeilmastoseminaari
Energy Technology Data Exchange (ETDEWEB)
The national energy research programme LVIS-2000: Future Building Services is concerned with the control of energy use and indoor climate in buildings of the future. The projects were presented at a one day seminar arranged by the Laboratory of Heating and Ventilation of the Technical Research Centre in Finland which is coordinating the programme. The presentations at the seminar were: Impurity emission from materials, Building materials and indoor air quality, analysis of organic compounds in indoor air, effect of the return air, effect of the return air on health and comfort, electric heating as an indoor climate factor, calculations of air flows in ventilated rooms, effect of energy saving measures on hospital hygiene, application of modern aerosol measurement technique on indoor climate research.
1989-12-31
Emittance of boehmite and alumina films on 6061 aluminium alloy between 295 and 773 K
International Nuclear Information System (INIS)
The total hemispherical emittance of an oxide film that formed on 6061-T6 aluminium alloy parts in the Tower Shielding Reactor-II at Oak Ridge National Laboratory was measured from 295 to 773 K using an emissometer and/or a calorimeter. The emittance of this film was critically needed for heat transfer calculations in a simulated loss-of-coolant accident of the reactor. X-ray diffraction analysis identified the film as boehmite (Al_2O_3 x H_2O), which dehydrated to alumina (Al_2O_3) upon heating above 473 K. The measured emittances for the alumina film are in excellent agreement with published values for anodized aluminum films and for bulk alumina. Published values of the emittance of boehmite could not be found for comparison, but evidence is presented that some anodization processes for aluminum yield boehmite and not alumina films.
1991-01-01
Eluates from pyrolysed refuse. Eluate aus pyrolysiertem Hausmuell
Energy Technology Data Exchange (ETDEWEB)
The solubility behavior of solid residues from the heat treatment of domestic rubbish was examined by simulated precipitation in laboratory lysimeters. The precipitation corresponded to the average amount of rain in West Germany and was applied at different time periods. Specific soil characteristics, the value of k/sub f/ and the water retention capacity was determined in this way. In parallel with the lysimeter flood ions, extraction (by batch process) was done, in order to find the maximum solubility of the materials used. It was found that for pyrolysis residues from reactor temperatures of 450/sup 0/ to 1000/sup 0/C, a greater solubility was measured than for slag from combustion. The eluates from these residues gave information about the degree of contamination or on the solubility of the measured parameters and materials in organoleptic, physical, organic and inorganic examinations. The concentrations of harmful ...
1981-01-01
Design properties of coal liquids: edited workshop proceedings
The advent of synfuels will require a large measurement and modeling effort of new thermodynamic and physical properties. These data are required for the economic design and operation of proposed synfuel plants. The areas of data need are well defined. The pace of measurement will be restricted by laboratory availability. The cost for the required data and for their correlation and modeling will be substantial. And finally, the cost of doing all this work will be substantial. The plants we are talking about are energy plants and synfuel plants. They are energy intensive plants, and as such, they offer the prospects for a great deal of energy saving. To do so requires good data. In those critical areas where we start hunting the energy hogs, we will find that with +-20% data those hogs are pretty well hidden.
1981-08-01
Energy Technology Data Exchange (ETDEWEB)
Radon proof barriers are used for lowering of radon transport from the soil into the house and the determination of the radon diffusion coefficient is an important parameter to be determined in order to design the minimal thickness of the radon proof insulation. A method has been developed in our laboratory by using modified Lucas cells connected to a radon source and tightly closed onto the top by the tested membranes whose radon diffusion coefficients are being measured. Solving the time-dependent differential equation for radon diffusion in the membrane for well-defined experimental conditions the effective radon diffusion coefficient of the insulating material can be evaluated by comparing the radon concentration decrease in the cell for the first hours with the well-known radioactive decay. First results obtained in several preliminary tests carried out with a parafilm M barrier and two polyethylene membranes are shown in this paper.
2005-01-01
Energy Technology Data Exchange (ETDEWEB)
Background: The difficulty of directly measuring cellular dose is a significant obstacle to application of target tissue dosimetry for nanoparticle and microparticle toxicity assessment. As a consequence, the target tissue paradigm for dosimetry and hazard assessment of nanoparticles has largely been ignored in favor of using metrics of exposure (e.g. ?g particle/mL culture medium, particle surface area/mL, particle number/mL). We have developed a computational model of solution particokinetics (sedimentation, diffusion) and dosimetry for non-interacting spherical particles and their agglomerates in monolayer cell culture systems. Particle transport to cells is calculated by simultaneous solution of Stokes Law (sedimentation) and the Stokes-Einstein equation (diffusion). Results: The In vitro Sedimentation, Diffusion and Dosimetry model (ISDD) was tested against measured transport rates or cellular doses for multiple sizes of polystyrene ...
2010-11-30
... Tactical Electronic Warfare Division (Code 5700) Visualization Laboratory Transportable step frequency radar Vehicle development laboratory ...
2011-05-15
... Tactical Electronic Warfare Division (Code 5700) Visualization Laboratory Transportable step frequency radar Vehicle development laboratory ...
2011-05-15
International Nuclear Information System (INIS)
Korea Atomic Energy Research Institute, using the ANS Low Power /Shutdown (LPSD)PRA Standard, evaluated the LPSD PSA model of the KSNP, Younggwang (YGN) Units 5 and 6, and identified the items to be improved. The evaluation results of human reliability analysis (HRA) of the pre-accident human errors in the LPSD PSA model of the KSNP showed that 13 items among 15 items of supporting requirements for those in the ANS PRA Standard were identified as them to be improved. Thus, we newly carried out a HRA for pre-accident human errors in the LPSD PSA model for the KSNP to improve its quality. We considered potential pre-accident human errors for all manual valves and control/instrumentation equipment of the systems modeled in the KSNP LPSD PSA model except reactor protection system/ engineering safety features actuation system. We reviewed 160 manual valves and 56 control/instrumentation equipment. The number of newly identified ...
2003-04-20
Energy Technology Data Exchange (ETDEWEB)
This report summarizes the work performed under the Sandia Laboratory Directed Research and Development (LDRD) project ``Optical Diagnostics for Turbulent and Multiphase Flows.`` Advanced optical diagnostics have been investigated and developed for flow field measurements, including capabilities for measurement in turbulent, multiphase, and heated flows. Particle Image Velocimetry (PIV) includes several techniques for measurement of instantaneous flow field velocities and associated turbulence quantities. Nonlinear photorefractive optical materials have been investigated for the possibility of measuring turbulence quantities (turbulent spectrum) more directly. The two-dimensional PIV techniques developed under this LDRD were shown to work well, and were compared with more traditional laser Doppler velocimetry (LDV). Three-dimensional PIV techniques were developed and tested, but due ...
1997-01-01
Measuring head for radionuclide X-ray fluorescence analyzer
International Nuclear Information System (INIS)
The design of a gaging head for a portable radionuclide X-ray fluorescence analyzer is described. The gaging head is designed as a construction unit system which enables the application of lateral reflexion geometry as well as of coaxial geometry. It is designed so that adjustment from one geometry to the other is labour and time saving. The selection of characteristic radiation is performed by a couple of Ross' differential filters. These filters are prepared by a novel technique developed by our laboratory. The filter exchange is effected by the longitudinal move of the couple of filters encapsulated in a holder. The shift of the filters is controlled by means of a triggering mechanism situated in the body of the gaging head handle. This design makes is possible to handle the gaging head during measurements with one hand. A simple interchange of the absorption filter for the transmissive filter allows the operator to avoid any unwanted shift ...
1976-05-21
International Nuclear Information System (INIS)
For 12C 9Be interactions at a kinetic beam energy of 3.2 GeV per nucleon, the spectra of photons at laboratory angles in the range 55o-73o were measured off the kinematical region available to the interaction of single nucleons within colliding nuclei. The use of a fast trigger for selecting events involving the production of high-transverse-momentum photons made it possible to measure spectra off the kinematical boundary of four-nucleon interaction. It is shown that the proposed procedure is adequate to the problem of searches for and investigation of flucton-flucton interaction. In the kinematical region where flucton-flucton interaction can manifest itself, the cross sections in question are on the same order of magnitude as respective model predictions. In order to draw definitive conclusions on the role of flucton-flucton interaction, it is highly desirable to extend the angular range of the ...
2008-11-01
Energy Technology Data Exchange (ETDEWEB)
Indoor and soil gas Radon ({sup 222}Rn) concentration measurements were accomplished in two stages in Sivas, a central eastern city in Turkey. In the first stage, CR-39 passive nuclear track detectors supplied by the Turkish Atomic Energy Authority (TAEA) were placed in the selected houses throughout Sivas centrum in two seasons; summer and winter. Before the setup of detectors, a detailed questionnaire form was distributed to the inhabitants of selected houses to investigate construction parameters and properties of the houses, and living conditions of inhabitants. Detectors were collected back two months later and analysed at TAEA laboratories to obtain indoor {sup 222}Rn gas concentration values. In the second stage, soil gas {sup 222}Rn measurements were performed using an alphameter near the selected houses for the indoor measurements. Although {sup 222}Rn concentrations in Sivas were quite low in ...
2010-11-15
Energy Technology Data Exchange (ETDEWEB)
Two measurement methods to determine the rate of neutral free radical production by the photo-deionization of negative ion beams (PDINIB) are introduced. These methods, namely, photoelectron-current measurement by low-frequency electro-modulation probe (PMMP) and measurement of decrease in the negative-ion beam current (DNIC) were employed to evaluate the production rate in a trial surface-processing apparatus developed in the author's laboratory utilizing a steady-flux refined beam of neutral free radicals (RBNR) produced by the PDINIB procedure. A {sup 63}Cu{sup -} negative ion beam of kinetic energy E{sub i} varied up to 15 keV was irradiated with a 514.5 nm visible light beam from a 25 W CW Ar{sup +} ion laser. The detection limit of the production rate by the PMMP setup was as high as 6 x 10{sup 9} s{sup -1} under the condition that E{sub i}=15 keV, the negative-ion beam current I{sub i}=4 ...
2003-05-01
Sandia National Laboratories/California site environmental report for 1997
Energy Technology Data Exchange (ETDEWEB)
Sandia National Laboratories (SNL) is committed to conducting its operations in an environmentally safe and sound manner. It is mandatory that activities at SNL/California comply with all applicable environmental statutes, regulations, and standards. Moreover, SNL/California continuously strives to reduce risks to employees, the public, and the environment to the lowest levels reasonably possible. To help verify effective protection of public safety and preservation of the environment, SNL/California maintains an extensive, ongoing environmental monitoring program. This program monitors all significant effluents and the environment at the SNL/California site perimeter. Lawrence Livermore National Laboratory (LLNL) performs off-site external radiation monitoring for both sites. These monitoring efforts ensure that emission controls are effective in preventing contamination of the environment. As part of SNL/California`s Environmental Monitoring ...
1998-06-01
Energy Technology Data Exchange (ETDEWEB)
This study of the hydrogeology of Chicken Creek Canyon wasconducted by the Environmental Restoration Program (ERP) at LawrenceBerkeley National Laboratory (LBNL). This canyon extends downhill fromBuilding 31 at LBNL to Centennial Road below. The leading edge of agroundwater tritium plume at LBNL is located at the top of the canyon.Tritium activities measured in this portion of the plume during thisstudy were approximately 3,000 picocuries/liter (pCi/L), which issignificantly less than the maximum contaminant level (MCL) for drinkingwaterof 20,000 pCi/L established by the Environmental ProtectionAgency.There are three main pathways for tritium migration beyond theLaboratory s boundary: air, surface water and groundwater flow. Thepurpose of this report is to evaluate the groundwater pathway.Hydrogeologic investigation commenced with review of historicalgeotechnical reports including 35 bore logs and 27 test pit/trench logsas ...
2007-10-31
Air quality monitoring Lloydminster area : 2002, 2003 and 2004 seasonal monitoring : final report
Energy Technology Data Exchange (ETDEWEB)
As part of its air quality monitoring activities, Alberta Environment conducts unannounced mobile air quality surveys each year using the Department's Mobile Air Monitoring Laboratory (MAML). This laboratory provides a snapshot of the air quality at the location monitored for a particular time and space. The MAML measures several pollutants in the air including ammonia, carbon monoxide, hydrocarbons, oxides of nitrogen, ozone, particulate matter, reduced sulphur compounds and sulphur dioxide. Alberta Environment conducted a series of ambient air quality monitoring surveys in the Lloydminster Area in 2002, 2003 and 2004. This report presents the results of the five monitored locations over eight seasons of monitoring, which were selected in consultation with stakeholders and staff from Alberta Environment's Central Region office. Canister samples were also collected during these surveys for later ...
2005-11-01
Direct observation of ordered orbital of YTiO{sub 3} by the X-ray magnetic diffraction technique
Energy Technology Data Exchange (ETDEWEB)
X-ray magnetic diffraction (XMD) technique was applied to an orbital ordering compound of ferromagnetic YTiO{sub 3} for the first time. The orbital-magnetic form factor {mu} {sub L}(k) and the spin-magnetic form factor {mu} {sub S}(k) were independently measured by utilizing the LS separation ability of the XMD. The {mu} {sub L}(k) was measured for ten reciprocal-lattice points. No significant values of the {mu} {sub L}(k) were observed for most of the reciprocal-lattice points within the estimated statistical errors, which suggested quenching of the orbital moment. The {mu} {sub S}(k) was measured for 22 reciprocal-lattice points. Fourier synthesis of the {mu} {sub S}(k) gave the spin density distribution m {sub S}(r) in the real space. The obtained m {sub S}(r) map shows the characteristic feature of the electron distribution of 3d electron in the t{sub 2g} state of a Ti atom coordinated by O{sup 2-} ...
2005-08-15
Binary Error Correcting Network Codes
We consider network coding for networks experiencing worst-case bit-flip errors, and argue that this is a reasonable model for highly dynamic wireless network transmissions. We demonstrate that in this setup prior network error-correcting schemes can be arbitrarily far from achieving the optimal network throughput. We propose a new metric for errors under this model. Using this metric, we prove a new Hamming-type upper bound on the network capacity. We also show a commensurate lower bound based on GV-type codes that can be used for error-correction. The codes used to attain the lower bound are non-coherent (do not require prior knowledge of network topology). The end-to-end nature of our design enables our codes to be overlaid on classical distributed random linear network codes. Further, we free internal nodes from having to implement potentially computationally intensive link-by-link ...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
An estimate of the tritium dose to the public in the vicinity of the heavy water research reactor facility at AECL-Chalk River Laboratories, Ontario, Canada, has largely been accomplished from analyses on regularly-collected samples of air, precipitation, drinking water and foodstuffs (pasture, fruit, vegetables and milk) and environmental dose models. To increase the confidence with which public doses are calculated, tritium doses were estimated directly from the ratio of tritiated species in urine samples from members of the general public. Single cumulative 24 h urine samples from a few adults living in the vicinity of the heavy-water research reactor facility at Chalk River Laboratories, Canada were collected and analysed for tritiated water and organically bound tritium. The participants were from Ottawa (200 km east), Deep River (10 km west) and Chalk River Laboratories. Tritiated water concentrations in urine ranged ...
2001-07-01
Future needs and requirements for AMS "1"4C standards and reference materials
International Nuclear Information System (INIS)
"1"4C measurement uses a number of standards and reference materials with different properties. Historically the absolute calibration of "1"4C measurement was tied to 1890 wood, through the 'primary' standard of NBS-OxI (produced by the National Bureau of Standards, now NIST - National Institute of Standards and technology) subsequently replaced by NBS-OxII. These are both internationally calibrated and certified materials, whose "1"4C activities are known absolutely. A second tier of materials, often called secondary standards or reference materials, and including internationally recognised materials such as ANU-sucrose (now also IAEA-C6), Chinese - sucrose and the IAEA C1-C6 series, augmented by additional oxalic acid samples are also used routinely. The activity of these materials has been estimated from large numbers of measurements made by many laboratories. Recently, further natural materials from ...
2004-08-01
Winter study of power plant effects
Energy Technology Data Exchange (ETDEWEB)
As a part of DOE's Meteorological Effects of Thermal Energy Releases (METER) program a field study was undertaken at the Bowen Electric Generating Plant (Plant Bowen) in December 1979. The study was a joint endeavor of Battelle Pacific Northwest Laboratories (PNL), Pennsylvania State University (PSU), and Oak Ridge National Laboratory (ORNL) with the main objective of determining the effects of the plant's smokestack effluents on aerosol characteristics and precipitation chemistry. Other objectives included studies of cooling tower temperature and humidity (T/h) plumes and drift drop concentrations. Conducted over a period of three weeks, the study involved an instrumented aircraft, pilot balloons, a tethered balloon system, a dense network of wetfall chemistry collectors and numerous ground- and tower-based meteorological instruments. Rainfall samples collected during the precipitation event of December 13, 1979, revealed ...
1980-10-01
Energy Technology Data Exchange (ETDEWEB)
Prompt fission neutron spectrum measurements at the University of Massachusetts Lowell 5.5 MV Van de Graaff accelerator laboratory require that the neutron detector efficiency be well known over a neutron energy range of 100 keV to 20 MeV. The efficiency of the detector, has been determined for energies greater than 5.0 MeV using the Weapons Neutron Research (WNR) white neutron source at the Los Alamos Meson Physics Facility (LAMPF) in a pulsed beam, time-of-flight (TOF) experiment. Carbon matched polyethylene and graphite scatterers were used to obtain a hydrogen spectrum. The detector efficiency was determined using the well known H(n,n) scattering cross section. Results are compared to the detector efficiency calculation program SCINFUL available from the Radiation Shielding Information Center at Oak Ridge National Laboratory.
1994-06-01
Energy Technology Data Exchange (ETDEWEB)
The performance of a geologic repository for high-level nuclear waste will be influenced to a large degree by thermohydrologic phenomena created by the emplacement of heat-generating radioactive waste. The importance of these phenomena is manifest in that they can greatly affect the movement of moisture and the resulting transport of radionuclides from the repository. Thus, these phenomena must be well understood prior to a definitive assessment of a potential repository site. An investigation has been undertaken along three separate avenues of analysis: (i) laboratory experiments, (ii) mathematical models, and (iii) similitude analysis. A summary of accomplishments to date is as follows. (1) A review of the literature on the theory of heat and mass transfer in partially saturated porous medium. (2) A development of the governing conservation and constitutive equations. (3) A development of a dimensionless form of the governing equations. (4) A numerical study of ...
1993-07-01
Proceedings of the summary seminar within the NKS-B programme 2002-2005[Radioecology
Energy Technology Data Exchange (ETDEWEB)
This report contains the proceedings of the NKS-B Summary Seminar held on 24-25 October 2005 in Tartu, Estonia. The aim of the seminar was to provide a forum for presenting and discussing the results obtained in the NKS-B programme during the project period 2002 - 2005. The main attention was focused on radioecology and measurement techniques including presentations on the work done in the Projects INDOFERN (New Indicator Organisms for Environmental Radioactivity), LABINCO (Intercomparison of Laboratory Analyses of Radionuclides in Environmental Samples) and ECODOSES (Improving Radiological Assessments of Doses to Humans from Terrestrial Ecosystems). The total number of presentations in the seminar was 27. The seminar was also the final seminar of the four-year INDOFERN Project. The objective of the project was to identify new indicator organisms and biomarkers for assessment of environmental radioactivity in normal and emergency situations. ...
2006-04-15
On-line analysis of chemical composition using an FT-Raman spectrometer in the near-ir
Newly commercialized Fourier transform Raman spectroscopic instrumentation provides a simpler alternative for vibrational spectroscopic analysis. Instrument vendors currently design for laboratory use, but there are many potential process applications of these stable, easy to use instruments. Raman spectroscopy is highly suited to analysis of aqueous samples. Near infrared excitation minimized fluorescence interference and allows for remote operation via fiber optic probes. The Department of Energy has funded research at the Measurement and Control Center to establish the utility of this method for on-line composition analysis in distillation columns. Laboratory evaluation and instrument employs an air-cooled laser and a thermoelectrically cooled detector. The device is mounted on a three by foot cart for convenient location in control rooms. Current fiber optic extension cables allow for analysis in a cell thirty five ...
1992-01-01
Energy Technology Data Exchange (ETDEWEB)
A testing program has been conducted by the Westinghouse Hanford Company to confirm the baseline waste form selection for use in Waste Receiving and Processing (WRAP) Module 2A. WRAP Module 2A will provide treatment required to properly dispose of containerized contact-handled, mixed low-level waste at the US Department of Energy Hanford Site in south-central Washington State. Solidification/stabilization has been chosen as the appropriate treatment for this waste. This work is intended to test cement-based, thermosetting polymer, and thermoplastic polymer solidification media to substantiate the technology approach for WRAP Module 2A. Screening tests were performed using the major chemical constituent of each waste type to measure the gross compatibility with the immobilization media and to determine formulations for more detailed testing. Surrogate materials representing each of the eight waste types were prepared in the laboratory. These ...
1993-10-01
Investigations of biomimetic light energy harvesting pigments
Energy Technology Data Exchange (ETDEWEB)
This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at Los Alamos National Laboratory (LANL). Nature uses chlorophyll and other porphyrinic pigments to capture and transfer light energy as a preliminary step in photosynthesis. The design of synthetic assemblies of light harvesting and energy directing pigments has been explored through synthesis and characterization of porphyrin oligomers. In this project, pigment electronic and vibrational structures have been explored by electrochemistry and dynamic and static optical measurements. Transient absorption data reveal energy transfer between pigments with lifetimes on the order of 20--200 picoseconds, while Raman data reveal that the basic porphyrin core structure is unperturbed relative to the individual monomer units. These two findings, along with an extensive series of experiments on the oxidized oligomers, reveal that ...
1998-12-01
Energy Technology Data Exchange (ETDEWEB)
Previous laboratory tests of elastomer O-rings in coal liquefaction solvents conducted at L'Garde, Inc., indicated that certain ethylenepropylenediene monomer (EPDM) compounds provided the best performance when a backup ring was used to limit swelling. Before service testing in a pump at the Wilsonville, Alabama, Advanced Coal Liquefaction Research and Development Facility, tests of six selected elastomers in the appropriate Wilsonville-produced solvent were conducted at Oak Ridge National Laboratory (ORNL). The ORNL tests measured the elastomers' changes in cross section, weight, density, and relative flexibility. Although two perfluoroelastomers showed less degradation of most properties during these tests, it was decided to proceed with service testing of two EPDM elastomers because of their much lower cost. 5 refs., 14 figs., 7 tabs.
1986-08-01
Current status and future plan of JMTR Hot Laboratory
Energy Technology Data Exchange (ETDEWEB)
The newly developed techniques by the Hot Laboratory (JMTR HL) have provided for us the key information on behavior of specimens due to mechanical / physical / chemical / synergistic effects of radiation, stress and water for fission and fusion reactor environment. These techniques are focused on several topics as follows; (1) miniaturized specimen test for the development of fusion reactor materials, (2) slow strain rate tensile testing (SSRT) and crack propagation measuring tests for the study of Irradiation Assisted Stress Corrosion Cracking (IASCC) of core internals of LWR, (3) handling technique on specimens including tritium for the research and development of tritium breeders and neutron multiplier as fusion blanket materials, (4) joining method using the Tungsten Inert Gas (TIG) welding technique for re-assembling of capsule and re-fabrication of specimen and (5) nondestructive evaluation using ultrasonic wave and infrared thermography ...
1999-08-01
Bendable Focusing X-Ray Optics for the ALS and the LCLS/FEL: Design, Metrology, and Performance
Energy Technology Data Exchange (ETDEWEB)
We review the recent development of bendable x-ray optics used for focusing of beams of soft and hard x-rays at the Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory and at the Linac Coherent Light Source (LCLS) x-ray free electron laser (FEL) at the Stanford Linear Accelerator Center (SLAC) National Accelerator Laboratory. For simultaneous focusing in the tangential and sagittal directions, two elliptically cylindrical reflecting elements, a Kirkpatrick-Baez (KB) pair, are used. Because fabrication of elliptical surfaces is complicated, the cost of directly fabricated tangential elliptical cylinders is often prohibitive. Moreover, such optics cannot be easily readjusted for use in multiple, different experimental arrangements, e.g. at different focal distances. This is in contrast to flat optics that are simpler to manufacture and easier to measure by conventional interferometry. The tangential figure of ...
2010-06-02
A Permeability Model for Coal and Other Fractured, Sorptive-Elastic Media
Energy Technology Data Exchange (ETDEWEB)
This paper describes the derivation of a new equation that can be used to model the permeability behavior of a fractured, sorptive-elastic media, such as coal, under variable stress conditions commonly used during measurement of permeability data in the laboratory. The model is derived for cubic geometry under biaxial or hydrostatic confining pressures. The model is also designed to handle changes in permeability caused by adsorption and desorption of gases from the matrix blocks. The model equations can be used to calculate permeability changes caused by the production of methane from coal as well as the injection of gases, such as carbon dioxide, for sequestration in coal. Sensitivity analysis of the model found that each of the input variables can have a significant impact on the outcome of the permeability forecast as a function of changing pore pressure; thus, accurate input data are essential. The permeability model can also be used as a ...
2006-10-01
Symbol Error Rates of Maximum-Likelihood Detector: Convex/Concave Behavior and Applications
Convexity/concavity properties of symbol error rates (SER) of the maximum likelihood detector operating in the AWGN channel (non-fading and fading) are studied. Generic conditions are identified under which the SER is a convex/concave function of the SNR. Universal bounds for the SER 1st and 2nd derivatives are obtained, which hold for arbitrary constellations and are tight for some of them. Applications of the results are discussed, which include optimum power allocation in spatial multiplexing systems, optimum power/time sharing to decrease or increase (jamming problem) error rate, and implication for fading channels.
2007-01-01
Interpolation theory and influence of boundary conditions on room air diffusion
Energy Technology Data Exchange (ETDEWEB)
This paper analyses the errors caused by interpolation from existing cases for assessing indoor air flow, air quality and thermal comfort in an office. A sensitivity study is then provided to determine the influence of several boundary conditions on indoor air diffusion. The research is conducted numerically by using a low-Reynolds-number k-{epsilon} model. It can be concluded that the interpolation errors caused by the variations of solar radiation, window size, heat source location due to lighting, and the surface temperatures of interior walls are small and can be quantitatively determined. But it is difficult to estimate the errors introduced by the variations of furniture location and size. (author).
1991-01-01
Development of an analysis rule of diagnosis error for standard method of human reliability analysis
International Nuclear Information System (INIS)
This paper presents the status of development of Korea standard method for Human Reliability Analysis (HRA), and proposed a standard procedure and rules for the evaluation of diagnosis error probability. The quality of KSNP HRA was evaluated using the requirement of ASME PRA standard guideline, and the design requirement for the standard HRA method was defined. Analysis procedure and rules, developed so far, to analyze diagnosis error probability was suggested as a part of the standard method. And also a study of comprehensive application was performed to evaluate the suitability of the proposed rules.
2003-10-01
Transmutation of technetium in the Petten HFR. A comparison of measurements and calculations
Energy Technology Data Exchange (ETDEWEB)
Within the framework of the EFTTRA cooperation between CEA, ECN, EDF, FZK, IAM and ITU, six metallic {sup 99}Tc rods have been irradiated in the Petten HFR for 193 effective full power days. During this irradiation, more than 6% of the {sup 99}Tc has been transmuted to the stable {sup 100}Ru. At ECN, one of the six rods has been examined in the hot cell laboratory. The ruthenium concentration in the rod measured by Isotope Dilution Mass Spectrometry reaches 6.4% at 5 mm from the bottom of the rod and 6.0% at 5 mm from the top. Also the axial and radial distributions of the ruthenium have been measured by Electron Probe Micro Analysis. The ruthenium concentrations calculated by the three-dimensional Monte Carlo code KENO reach 6.1% at 5 mm from the bottom of the rod and 5.7% at 5 mm from the top. These values are in reasonable agreement with the measured ones. However, the calculated radial distribution ...
1996-10-01
... Congo. It is probable that the type locality Matadi is in error and is the location from ... specimens of this species have been collected between Matadi and Luozi. (click map to view...
Space Science - NASA Headquarters
Canada will provide telescope baffles and fine error sensor assemblies. ..... ( Ongoing) Flight tests aboard sounding rockets and balloon planned for FY 1995. .... the effects of incoming energetic particles and solar radiation on the ...
Real-Time Stability and Control Derivative Extraction From F-15 - NASA
and the estimated parameter covariance matrix is. 5. (25) where p in this case is the number of elements in the vector . The parameter standard errors, ?, ...
Publication Year - NASA Technical Reports Server
Abstract: Inertial navigation error analysis of space vehicle during reentry. NASA Center: Ames Research Center Publication Year: 1963 ...
Linac automated beam phase control system.
Energy Technology Data Exchange (ETDEWEB)
Adjustment of the rf phase in a linear accelerator is crucial for maintaining optimal performance. If phasing is incorrect, the beam will in general have an energy error and increased energy spread. While an energy error can be readily detected and corrected using position readings from beam position monitors at dispersion locations, this is not helpful for correcting energy spread in a system with many possible phase errors. Uncorrected energy spread results in poor capture efficiency in downstream accelerators, such as the Advanced Photon Source's (APS's) particle accumulator ring (PAR) or booster synchrotron. To address this issue, APS has implemented beam-to-rf phase detectors in the linac, along with software for automatic correction of phase errors. We discuss the design, implementation, and performance of these detectors and how they improved APS top-up operations.
2006-01-01
Energy Technology Data Exchange (ETDEWEB)
This is a presentation on Human Factors in reactor operations. It discusses issues that deal with power plant operations, training and design, operational effectiveness and safety, supporting people to achieve effective and error free performance.
2002-07-01
George C. - NASA Technical Reports Server
Indicated inertial navigation error and required update frequency. phasing, and times). Docking Phase. Range; range rate. Clock angle; clock angle rate ...
Evaluating concentration estimation errors in ELISA microarray experiments
UK PubMed Central (United Kingdom)
BackgroundEnzyme-linked immunosorbent assay (ELISA) is a standard immunoassay to estimate a protein's concentration in a sample. Deploying ELISA in a microarray format permits simultaneous...Full Text Available
Contamination Effects of Satellite Material Outgassing ...
... A detailed analysis of QCM errors is ... Surface Effects of Satellite Outgassing Products." AIAA Journal ... 9. Rauschenbach, H. S. Solar Cell Array Design ...
1990-12-01
Concurrent Error-Detecting Codes for Arithmetic Processors
2 is self-checking as described by Kolupaev. (ref. 21). ..... Kolupaev, S. G.: Self-Testing Residue. Trees. TR-49, Digital Systems ...
Competitive Mean-Squared Error Beamforming
... Therefore we develop a competitive beamforming ap- proach, in which the beamformer is designed to minimize the worst-case regret over all s(t ...
2004-12-20
CHANEXTDFS - Chandra Extended Deep Field South Survey Point Source ...
Jan 25, 2006 ... Source positions are determined using matched-filter and centroiding .... The upper 1-sigma statistical error in the full-band counts. ...
Assessment of informatization for the dispensing of medications at a university hospital
UK PubMed Central (United Kingdom)
INTRODUCTIONInformatics and automation are important tools for the reduction of work, errors and costs in a hospital pharmacy.OBJECTIVESTo describe...Full Text Available
2010-04-01
An Extended Kalman Filter for Use in a Shared Aperture ...
... used to track a point source target ... A one sigma tracking error of .2 ... LOOKING INFRARED SYSTEMS, *KALMAN FILTERING, SIGNAL PROCESSING ...
1978-12-01
AGARD Flight Test Techniques Series. Volume 1. Calibration ...
... of "position error" in the AGARD Multilingual Aeronautical ... when it cones into the aircraft flow field it ... on actual bank angle and separation, may be - ...
1983-09-01
A Detailed Investigation on Human-Related Unplanned Reactor Trip Events in Korea
International Nuclear Information System (INIS)
Human errors have been reported as one of the most significant causes of major events in nuclear power plants (NPPs). For example, Kim and Park found that about 23% of the major events that occurred at NPPs in Republic of Korea from 1986 to 2006 were caused by human errors. For this reason, a detailed analysis on human errors is an important task for increasing the safety of NPPs. Kim and Choi?2 analyzed 100 human-related unplanned reactor trip events in the Republic of Korea from 1986 to 2006 to consider the type of human errors based on the simple path model for human-induced unplanned reactor trips developed by Kim and Park. In this paper, we will investigate and perform a detailed analysis of the data to identify human-related unplanned reactor trip trends
2010-10-01
A Comparative Study of Weights and Sizes of Flat-Plate ...
... this correction results In only a email error, since the isothoraal tests wore run at roon tomporcturo, -nd simplifies the reduction of isotherme! ...
1947-07-01
/ /tLc - NASA Technical Reports Server
Inertial navigation error propagation. Hypersonic entry guidance techniques. Ablation effects on hypersonic aero-. Primary navigation and guidance ...
Environmental trace gas analysis by proton-transfer-reaction mass spectrometry (PTR-MS)
International Nuclear Information System (INIS)
The work presented here demonstrates the ability of proton-transfer-reaction mass spectrometry (PTR-MS) to perform fast-response measurements of volatile organic compounds (VOCs) (including methanol, acetonitrile, acetaldehyde, acetone, PAN-type compounds, alpha- and beta-pinene, nopinone and pinonaldehyde) at the pptv level and its versatile applicability in the field of environmental trace gas analysis. Laboratory and field experiments including various calibration techniques and intercomparisons with other measurement techniques such as gas chromatography, atmospheric pressure chemical ionization and Fourier transformation infrared spectroscopy were performed providing a first characterization of the PTR-MS instrument performance (sensitivity, detection limit, precision, accuracy). Typically a detection limit (S/N=2) of 50 pptv for a 10 s signal integration time, a precision of 5 % and an accuracy in the range between 10 ...
X-Ray Fluorescence in Research on the Cultural Heritage
Energy Technology Data Exchange (ETDEWEB)
Radionuclide X-ray fluorescence analysis is a method, which has many advantages for analysing various historic artefacts, as it is relatively cheap, sensitive and non-destructive, and it allows measurements in-situ. However, this analysis has also certain limitations especially concerning sensitivity to chemical elements only, irrespective of the compounds or chemical forms in which these elements have been bonded. In addition, light elements emitting very soft X-rays cannot be measured, and in order to detect a wide range of elements, it is necessary to carry out repeated measurements with different radiation sources. Despite these limitations, valuable information can be obtained about the composition of historic materials and data about the origin and age of these artefacts can be derived. Analyses of wall paintings, ancient metal sculptures or other objects of art provide the basis for historic considerations documented ...
2001-09-15
X-Ray Fluorescence in Research on the Cultural Heritage
International Nuclear Information System (INIS)
Radionuclide X-ray fluorescence analysis is a method, which has many advantages for analysing various historic artefacts, as it is relatively cheap, sensitive and non-destructive, and it allows measurements in-situ. However, this analysis has also certain limitations especially concerning sensitivity to chemical elements only, irrespective of the compounds or chemical forms in which these elements have been bonded. In addition, light elements emitting very soft X-rays cannot be measured, and in order to detect a wide range of elements, it is necessary to carry out repeated measurements with different radiation sources. Despite these limitations, valuable information can be obtained about the composition of historic materials and data about the origin and age of these artefacts can be derived. Analyses of wall paintings, ancient metal sculptures or other objects of art provide the basis for historic considerations documented ...
2001-09-01
Wireline well logging an underutilized technique in reservoir evaluation
Energy Technology Data Exchange (ETDEWEB)
Wireline well logs have three general uses in geothermal exploration and reservoir evaluation: reservoir parameter analysis, lithologic column determination, and reservoir size resolution. Reservoir flow testing data are acquired to understand the flow rate, life, and production potential of the geothermal reservoir. These data are a coarse subsurface measurement of the geothermal prospect. Wireline logs acquired from wells in a geothermal prospect are used to define in detail, or estimate the reservoir parameters of temperature, thickness, lateral size, amount of fracture and intergranular pore space, and the quantity and quality of fluid that might be produced. Laboratory measurements can be made on core samples and drill cuttings samples to define the intrinsic behavior of the materials and fluid that compose the geotheraml reservoir. Wireline log measurements are needed to correlate and link the ...
1981-01-01
Energy Technology Data Exchange (ETDEWEB)
An ASTER (advanced spaceborne thermal emission and reflection radiometer) is one of the image sensors. It is to be installed in an earth survey polar orbit platform satellite, EOS-AM1, which is to be launched in 1998, and it is going to start its operation. Data observed by the thermal infrared remote sensing of ASTER include the spectral emissivity, and the spectral emission reflectivity which is expressed by the function of temperature. It is required to overcome technical problems how to extract the spectral emissivity from the observed data. The spectral emissivity extracted from the remote sensing data by the MMD method, measured for samples collected in Cuprite area, Nevada, and/or measured at sampled points were compared to each other and discussed. The hemisphere spectral reflectivity, which is indirect spectral emissivity, agreed well with the direct spectral emissivity. Data suggesting the establishment of Kirchhoff`s law were ...
1996-10-01
Testing of Critical Features of Polysilicon MEMS
Energy Technology Data Exchange (ETDEWEB)
The behavior of MEMS devices is limited by the strength of critical features such as thin ligaments, oxide cuts joining layers, pin joints and hinges. Devices fabricated at Sandia's Microelectronic Development Laboratory have been successfully tested to investigate these features. A series of measurements were performed on samples with gage lengths of 15 to 1000 microns, using conventional and tungsten coated samples as well as samples that include the critical features of standard components in the test section. Specimens have a freely moving pin joint on one end that anchors the sample to the silicon die to allow rotation to reduce effects of bending. Each sample is loaded in uniaxial tension by pulling laterally with a flat tipped diamond in a computer-controlled Nanoindenter. Load is calculated by resolving the measured lateral and normal forces into the applied tensile force and frictional losses. The specimen ...
1999-12-02
Radionuclide release rates from spent fuel for performance assessment modeling
Energy Technology Data Exchange (ETDEWEB)
In a scenario of aqueous transport from a high-level radioactive waste repository, the concentration of radionuclides in water in contact with the waste constitutes the source term for transport models, and as such represents a fundamental component of all performance assessment models. Many laboratory experiments have been done to characterize release rates and understand processes influencing radionuclide release rates from irradiated nuclear fuel. Natural analogues of these waste forms have been studied to obtain information regarding the long-term stability of potential waste forms in complex natural systems. This information from diverse sources must be brought together to develop and defend methods used to define source terms for performance assessment models. In this manuscript examples of measures of radionuclide release rates from spent nuclear fuel or analogues of nuclear fuel are presented. Each example represents a very different ...
1994-11-01
PIXE-PIGE analysis of some Indian medicinal plants
Energy Technology Data Exchange (ETDEWEB)
The quantitative estimation of various trace element concentrations in medicinal plants is necessary for determining their effectiveness in treating various diseases and for understanding their pharmacological action. Elemental concentrations of some selected medicinal plants of north east India was measured by proton induced X-ray emission (PIXE) and proton induced {gamma}-ray emission (PIGE) techniques. PIXE measurements were carried out using 2.4 MeV collimated protons from the 3 MV tandetron accelerator of NCCCM, Hyderabad (India) while the PIGE measurements were carried out using 3 MeV protons from the same accelerator in the same laboratory. Accuracy and precision of the techniques were assured by analyzing certified reference materials in the same experimental conditions. Various elements of biological importance in man's metabolism were found to be present in varying concentrations in ...
2010-06-15
Neutron scattering and models: iron
Energy Technology Data Exchange (ETDEWEB)
Differential elastic and inelastic neutron-scattering cross sections of elemental iron are measured from 4.5 to 10 MeV in increments of {approx}0.5 MeV. The measurements are made at >or{approx}40 scattering angles distributed between {approx}17 and 160 , with emphasis on elastic scattering and inelastic scattering due to the excitation of the yrast 2{sup +} state. The measured data is combined with earlier lower-energy results from this laboratory, with recent high-precision {approx}9.5-15 MeV results from the Physikalisch. Technische Bundesanstalt and with selected values from the literature to provide a detailed neutron-scattering data base extending from {approx}1.5 to 26 MeV. This data is interpreted in the context of spherical-optical and coupled-channels (vibrational and rotational) models, and the physical implications are discussed. Deformation, coupling, asymmetry and dispersive effects are ...
1996-08-12
Energy Technology Data Exchange (ETDEWEB)
Three test instruments are being evaluated to determine the feasibility of using photoacoustic technology for measuring unburned carbon in fly ash. The first test instrument is a single microwave frequency system previously constructed to measure photoacoustic signals in an off-line configuration. A second off-line instrument was constructed based in part on lessons learned with the first instrument, but which also expands the capabilities of the first instrument. Improvements include a control loop to allow more constant microwave power output and an ability to operate over a range of microwave frequencies. The third instrument, the on-line version of the fly ash monitor, has been designed, constructed, and initial efficiency tests have been conducted on the monitor's electrical components. This quarter focused on improving the signal strength of the accelerometer by increasing the power level of the microwaves that induced the ...
2004-07-01
Energy Technology Data Exchange (ETDEWEB)
Gas transmission pipelines are susceptible to both internal (gas side) and external (soil side) corrosion attack. Internal corrosion is caused by the presence of salt laden moisture, CO{sub 2}, H{sub 2}S, and perhaps O{sub 2} in the natural gas. Internal corrosion usually manifests itself as general corrosion. However, the presence of chlorides in entrained water also can lead to pitting corrosion damage. The electrochemical noise technique can differentiate general from localized corrosion and provide estimates of corrosion rates without external perturbation of the corroding system. It is increasingly being applied to field and industrial installations for in situ corrosion monitoring. It has been used here to determine its suitability for monitoring internal and external corrosion damage on gas transmission pipelines. Corrosion measurements were made in three types of environments: (1) aqueous solutions typical of those found within gas pipelines in equilibrium ...
2003-03-16
International Nuclear Information System (INIS)
CEA-Valduc produces some radioactive waste (mainly alpha emitters). Legislation requires producers to sort their waste by activity and type of isotopes, and to package them in order to forward them to the appropriate reprocessing or storage facility. Our lab LMDE (laboratory for measurements on nuclear wastes and valuation) is in charge of the characterization of the majority of waste produced by CEA-Valduc. Among non-destructive methods to characterize a radioactive object, gamma-spectroscopy is one of the most efficient. We present to this conference the method we use to characterize nuclear waste and the system we developed to characterize our germanium detectors. The goal of this system is to obtain reliable numerical models of our detectors and calculate their efficiency curves. Measurements are necessary to checks models and improve them. These measurements are made on a bench using pinpoint ...
2009-06-07
Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument designed to measure polarization from astrophysical objects in the 30-100 keV range, under development by an international collaboration with members from United States, Japan, Sweden and France. To examine PoGO's capability, a beam test of a simplified prototype detector array was conducted at the Argonne National Laboratory Advanced Photon Source. The detector array consisted of seven plastic scintillators, and was irradiated by polarized photon beams at 60, 73, and 83 keV. The data showed a clear polarization signal, with a measured modulation factor of $0.42 \\pm 0.01$. This was successfully reproduced at the 10% level by the computer simulation package Geant4 after ...
2005-01-01
Absolute differential cross sections for the scattering of kilo-electron-volt O atoms
International Nuclear Information System (INIS)
This paper reports measurements of absolute differential cross sections for the direct scattering of oxygen atoms by He, Ne, Ar, Kr, Xe, H_2, N_2, O_2, CO, CO_2, H_2O, SO_2, NH_3, CH_4, CF_4, and SF_6 targets. The measured cross sections include contributions from all elastic and inelastic processes that result in a fast neutral oxygen atom product. Cross sections are presented for 0.5- and 1.5-keV projectile energies over the laboratory angular range 0.2 degree endash 5 degree. When compared in the center-of-mass reference frame, these cross sections exhibit a high degree of similarity in both amplitude and angular dependence. The cross sections for N_2, CO, CO_2, and H_2O are inverted using a partial-wave analysis to yield empirical interaction potentials, which can then be used to extrapolate the measurements down to lower energies. Using these potentials, cross sections are evaluated at 0.1 keV. ...
Subcritical Noise Analysis Measurements with Fresh and Spent Research Reactor Fuels Elements
Energy Technology Data Exchange (ETDEWEB)
The verification of the subcriticality is of utmost importance for the safe transportation and storage of nuclear reactor fuels. Transportation containers and storage facilities are designed such that nuclear fuels remain in a subcritical state. Such designs often involve excess conservatism because of the lack of relevant experimental data to verify the accuracy of Monte Carlo codes used in nuclear criticality safety analyses. A joint experimental research program between Oak Ridge National Laboratory, Westinghouse Safety Management Solutions, Inc., and the University of Missouri was initiated to obtain measured quantities that could be directly related to the subcriticality of simple arrays of Missouri University Research Reactor (MURR) fuel elements. A series of measurement were performed to assess the reactivity of materials such as BORAL, stainless steel, aluminum, and lead that are typically used in the construction ...
1999-02-01
Radon in soil gas survey in Curitiba (Brazil)
International Nuclear Information System (INIS)
This work describes the radon in soil gas measurements performed during the last two years in cooperation between the Laboratory of Applied Nuclear Physics of the Federal University of Technology (UTFPR), the Nuclear Technology Development Center (CDTN) and the Institute of Radiation Protection and Dosimetry (IRD) from the Brazilian Nuclear Energy Commission (CNEN). Following previously concluded measurements of radon concentration in dwellings and the measurements of 222Rn activity in drinking water collected at artesian bores of Curitiba urban area, present step of activities has been dedicated to measurements of radon concentration in soil gas. Experimental setup was based on the Professional Radon Monitor (ALPHA GUARD) connected to specially developed for such measurements Soil Gas Probe through the air pump and filter system. After the Probe was inserted, ...
2002-10-08
Prompt fission neutron energy spectra induced by fast neutrons
International Nuclear Information System (INIS)
Prompt fission neutron energy spectra for "2"3"5U and "2"3"9Pu have been measured for fission neutron energies greater than the energy of the incident neutrons inducing fission. The measurements were undertaken to investigate the shape dependence of the fission neutron spectra upon both the incident neutron energy and the mass of the nucleus undergoing fission. Measurements were made for both nuclides at incident neutron energies of 0.50, 1.50, 2.50 and 3.50 MeV. The data are presented either as relative yields or as ratios of measured spectra to that of "2"3"5U at 0.50 MeV. Incident neutrons were produced by the "7Li(p,n)"7Be reaction using a pulsed, bunched proton beam from the 5.5 MV Van de Graaff accelerator at the University of Massachusetts Lowell Radiation Laboratory. Fission neutrons were detected by a thin liquid scintillator with good time resolution capabilities. Neutron ...
Energy Technology Data Exchange (ETDEWEB)
The overall goal of the proposed project is to explore the use of partitioning tracers to characterize dense nonaqueous phase liquids (DNAPLs) in aquifer systems. Bulk-phase partitioning tracers will be investigated to detect and determine DNAPL saturation, while interface partitioning tracers will be investigated to measure the area of the DNAPL-water interface. The specific objectives that will be addressed to accomplish this goal are: (1) Investigate the use of partitioning tracers to detect and determine both the saturation and interfacial area of DNAPLs in saturated porous media. (2) Investigate the effect of rate-limited mass transfer on the transport behavior of partitioning tracers. (3) Investigate the effect of porous-media heterogeneity on the transport behavior of partitioning tracers. (4) Develop and evaluate mathematical models capable of simulating the transport of partitioning tracers in complex systems. This proposal outlines an integrated approach ...
2000-09-14
Energy Technology Data Exchange (ETDEWEB)
Because of the chaotic nature of the corrosion process and the complexity of the electrochemical noise signals that are generated, there is no generally accepted method of measuring and interpreting these signals that allows the consistent detection and identification of sustained localized pitting (SLP) as compared to general corrosion. We have reexamined electrochemical noise analysis (ENA) of localized corrosion using different hardware, signal collection, and signal processing designs than those used in conventional ENA techniques. The new data acquisition system was designed to identify and monitor the progress of SLP by analyzing the power spectral density (PSD) of the trend of the corrosion current noise level (CNL) and potential noise level (PNL). Each CNL and PNL data point was calculated from the root-mean- square value of the ac components of current and potential fluctuation signals, which were measured simultaneously during a short ...
1999-01-13
International Nuclear Information System (INIS)
Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and potentially damaging to instrumentation that may be used for diagnostics. To provide shielding for ...
Corrosion probes for fireside monitoring in coal-fired boilers
Energy Technology Data Exchange (ETDEWEB)
Corrosion probes are being developed and combined with an existing measurement technology to provide a tool for assessing the extent of corrosion of metallic materials on the fireside in coal-fired boilers. The successful development of this technology will provide power plant operators the ability to (1) accurately monitor metal loss in critical regions of the boiler, such as waterwalls, superheaters, and reheaters; and (2) use corrosion rates as process variables. In the former, corrosion data could be used to schedule maintenance periods and in the later, processes can be altered to decrease corrosion rates. The research approach involves laboratory research in simulated environments that will lead to field tests of corrosion probes in coal-fired boilers. Laboratory research has already shown that electrochemically-measured corrosion rates for ash-covered metals are similar to actual mass loss ...
2005-01-01
Volumetric quantification of brain development using MRI
International Nuclear Information System (INIS)
We devised a three-dimensional method for estimation of cerebral development and myelination which measures cerebral volume using MRI. Accuracy of the system was estimated using cadaver brains. The mean percentage error in the calculated volumes compared with the real volumes was 2.33 %, range 0.00-5.33 %. We applied the method to the volume of both cerebral hemispheres (CH), basal ganglia, thalamus and internal capsule (BT), and myelinated white matter (WM) in 44 neurologically normal individuals (4 months to 28 years of age), 13 patients with spastic motor disturbances (2-25 years of age), and 9 patients with athetotic motor disturbances (2-23 years of age). In the neurologically normal cases, the volumes of CH, BT and WM increased with age; the volume of MW more slowly than that of CH. In cases with spastic motor disturbances, the volumes of CH, BT and WM were between -1.4 and 3.5 SD, -1.0 and -3.5 SD, and 0.0 and -5.2 SD respectively, of ...
Energy Technology Data Exchange (ETDEWEB)
In rat adipocyte membranes, both beta-adrenergic agonists and beta-adrenergic antagonists competed with (--)(/sup 3/H)dihydroalprenolol for high affinity (KD 2-4 nM) and low capacity binding sites. The antagonists but not the agonists competed with (--)(/sup 3/H)dihydroalprenolol for lower affinity and higher capacity sites. The present studies were performed in order to characterize the adipocyte beta-adrenergic receptor and distinguish it from low affinity, higher capacity sites which were heat-labile and not stereoselective. When isoproterenol was used to define the nonspecific binding, saturation studies showed a single binding site with a capacity of approximately 100 fmol/mg membrane protein (corresponding to approximately 50,000 sites/adipocyte). Binding was saturated by 10 nM (--)(/sup 3/H)dihydroalprenolol. Approximate KD's of 204 nM were observed. Kinetic analysis of (--)(/sup 3/H)dihydroalprenolol binding provided an independent measurement of ...
1982-09-01
THE M-#sigma# AND M-L RELATIONS IN GALACTIC BULGES, AND DETERMINATIONS OF THEIR INTRINSIC SCATTER
International Nuclear Information System (INIS)
We derive improved versions of the relations between supermassive black hole mass (M _B_H) and host-galaxy bulge velocity dispersion (#sigma#) and luminosity (L; the M-#sigma# and M-L relations), based on 49 M _B_H measurements and 19 upper limits. Particular attention is paid to recovery of the intrinsic scatter (#epsilon#_0) in both relations. We find log(M _B_H/M _s_u_n) = #alpha# + #beta#log(#sigma#/200 km s"-"1) with (#alpha#, #beta#, #epsilon#_0) = (8.12 #+-# 0.08, 4.24 #+-# 0.41, 0.44 #+-# 0.06) for all galaxies and (#alpha#, #beta#, #epsilon#_0) = (8.23 #+-# 0.08, 3.96 #+-# 0.42, 0.31 #+-# 0.06) for ellipticals. The results for ellipticals are consistent with previous studies, but the intrinsic scatter recovered for spirals is significantly larger. The scatter inferred reinforces the need for its consideration when calculating local black hole mass function based on the M-#sigma# relation, and further implies that there may be substantial selection bias in ...
2009-06-10
Precise measurements of alpha particle counting efficiencies and mean ranges
International Nuclear Information System (INIS)
Precise measurements of alpha particle counting efficiencies have been made using isotropic, infinitely thin alpha emitting sources placed in direct contact with a thin, end-window, gas flow proportional detector. Except for alpha particle absorption in the window material, this geometry approaches 2#pi#, such that the only other variation in the response of the counter is from the random decay of the source. The data are fitted to the expected linear function of count rate versus window thickness and the resulting fitting parameters are used to calculate the counting efficiencies for a given thickness of window material. Counting efficiencies for 5.31, 6.06, and 8,78 MeV alpha particles have been determined from sources of "2"1"0Po and the progeny of "2"1"2Pb. For the particular counter used, the counting efficiencies in counts per alpha and their respective relative standard deviations were 0.401 #+-# 0.12%, 0.418 #+-# 0.41%, and 0.455 #+-# 0.10%. The isotropic, ...
1978-12-01
International Nuclear Information System (INIS)
Penning trap mass spectrometry is presented as a complementary tool to nuclear spectroscopy experiments for the study of nuclear structure in the vicinity of N=40, Z=28. High-precision mass measurements of the "6"3"-"6"6Fe and "6"4"-"6"7Co isotopes have been carried out with the Low Energy Beam and Ion Trap (LEBIT) Penning trap mass spectrometer. The newly obtained mass values for "6"6Fe and "6"7Co are presented, together with the previously reported LEBIT mass measurements in this region. In the case of "6"5Fe the existence of a new isomer is reported, and an isomer recently discovered by decay spectroscopy in "6"7Co is confirmed. Relative mass uncertainties as low as 4x10"-"8 are obtained. All mass values are found to be in good agreement with previous experimental results with the exception of "6"4Co, where a 5#sigma# deviation is observed. Using these data the two neutron separation energies S_2_n are calculated. However, the large ...
2010-04-01
Improved eddy-current inspection for steam generator tubing
International Nuclear Information System (INIS)
Computer programs have been written to allow the analysis of different types of eddy-current probes and their performance under different steam generators test conditions. The probe types include the differential bobbin probe, the absolute bobbin probe, the pancake probe and the reflection probe. The generator test conditions include tube supports, copper deposits, magnetite deposits, denting, wastage, pitting, cracking, and intergranular attack. These studies are based mostly on computed values, with the limited number of test specimens available used to verify the computed results. The instrument readings were computed for a complete matrix of the different test conditions, and then the test conditions determined as a function of the readings by a least-squares technique. A comparison was made of the errors in fit and instrument drift for the different probe types. The computations of the change in instrument reading due to the defects have led to an inversion ...
1990-03-01
Experimental study of nanoparticles penetration through commercial filter media
Energy Technology Data Exchange (ETDEWEB)
In this study, nanoparticle penetration was measured with a wide range of filter media using silver nanoparticles from 3 nm to 20 nm at three different face velocities in order to define nanoparticle filtration characteristics of commercial fibrous filter media. The silver particles were generated by heating a pure silver powder source via an electric furnace with a temperature of 870 deg. C, which was found to be the optimal temperature for generating an adequate amount of silver nanoparticles for the size range specified above. After size classification using a nano-DMA, the particle counts were measured by an Ultrafine Condensation Particle Counter (UCPC) both upstream and downstream of the test filter to determine the nanoparticle penetration for each specific particle size. Particle sampling time continued long enough to detect more than 10{sup 5} counts at the upstream and 10 counts at the downstream sampling point so that 99.99% ...
2007-01-15
Cosmic Evolution of Black Holes And Spheroids. 1, the M(BH)-Sigma Relation at Z=0.36
Energy Technology Data Exchange (ETDEWEB)
We test the evolution of the correlation between black hole mass and bulge velocity dispersion (M{sub BH} - {sigma}), using a carefully selected sample of 14 Seyfert 1 galaxies at z = 0.36 {+-} 0.01. We measure velocity dispersion from stellar absorption lines around Mgb (5175 {angstrom}) and Fe (5270 {angstrom}) using high S/N Keck spectra, and estimate black hole mass from the H{beta} line width and the optical luminosity at 5100 {angstrom}, based on the empirically calibrated photo-ionization method. We find a significant offset from the local relation, in the sense that velocity dispersions were smaller for given black hole masses at z = 0.36 than locally. We investigate various sources of systematic uncertainties and find that those cannot account for the observed offset. The measured offset is {Delta} log M{sub BH} = 0.62 {+-} 0.10 {+-} 0.25, i.e. {Delta} log {sigma} = 0.15 {+-} 0.03 {+-} 0.06, where the error bars ...
2006-04-17
Comparison of helmet-mounted display designs in support of infantry wayfinding
The Canadian Soldier Information Requirements Technology Demonstration (SIREQ TD) soldier modernization research and development program has conducted experiments to help determine the types and amount of information needed to support wayfinding across a range of terrain environments, the most effective display modality for providing the information (visual, auditory or tactile) that will minimize conflict with other infantry tasks, and to optimize interface design. In this study, seven different visual helmet-mounted display (HMD) designs were developed based on soldier feedback from previous studies. The displays and an in-service compass condition were contrasted to investigate how the visual HMD interfaces influenced navigation performance. Displays varied with respect to their information content, frame of reference, point of view, and display features. Twelve male infantry soldiers used all eight experimental conditions to locate bearings to waypoints. From a constant location, ...
2003-09-01
Calibration free laser-induced breakdown spectroscopy of oxide materials
Energy Technology Data Exchange (ETDEWEB)
The quantitative determination of oxide concentration by laser-induced breakdown spectroscopy is relevant in various fields of applications (e.g.: analysis of ores, concrete, slag). Calibration free laser-induced breakdown spectroscopy and the multivariate calibration are among the methods employed for quantitative concentration analysis of complex materials. We measured the intensity of neutral and ionized atomic emission lines of oxide materials by laser-induced breakdown spectroscopy and we modified the calibration free laser-induced breakdown spectroscopy method to increase the accuracy. The concentration of oxides was obtained by using stoichiometric relations. Sample materials were prepared from oxide powder (Fe{sub 2}O{sub 3}, MgO, CaO) by mixing and pressing. The concentration was 9.8-33.3 wt.% Fe{sub 2}O{sub 3}, 7.6-33.3 wt.% MgO and 33.3-81.2 wt.% CaO for different samples. Nd:YAG laser (wavelength 1064 nm, pulse duration {approx} 6 ns) ablation was ...
2010-08-15
X-ray fluorescence in research on Czech cultural monuments
Energy Technology Data Exchange (ETDEWEB)
Radionuclide X-ray fluorescence analysis (RXRFA), as a non-destructive method, relatively simple and allowing measurements to be carried out in situ, is an excellent tool in research on various objects of art. A range of artefacts have been investigated by our laboratory, in part for the purposes of history of art and in part as a basis for restoration works - medieval frescoes in some Czech castles and churches, metal sculptures and objects of applied art, paints and inks of old manuscripts, paintings. Some of these are among the most valuable monuments in the Czech cultural heritage. The contribution of the results of the tests to the investigation of their 'life story' and, in some cases, to their conservation, is not negligible. Later additions and repairs can be recognised, and materials and technologies that are close to their historic counterparts can be used in restoration work.
2004-01-01
X-ray fluorescence in research on Czech cultural monuments
International Nuclear Information System (INIS)
Radionuclide X-ray fluorescence analysis (RXRFA), as a non-destructive method, relatively simple and allowing measurements to be carried out in situ, is an excellent tool in research on various objects of art. A range of artefacts have been investigated by our laboratory, in part for the purposes of history of art and in part as a basis for restoration works - medieval frescoes in some Czech castles and churches, metal sculptures and objects of applied art, paints and inks of old manuscripts, paintings. Some of these are among the most valuable monuments in the Czech cultural heritage. The contribution of the results of the tests to the investigation of their 'life story' and, in some cases, to their conservation, is not negligible. Later additions and repairs can be recognised, and materials and technologies that are close to their historic counterparts can be used in restoration work.
2004-01-01
Use of a novel acoustic dissolved oxygen transmitter for fish telemetry
DEFF Research Database (Denmark)
The multiple responses of fishes to changes in dissolved oxygen saturations have been studied widely in the laboratory. In contrast only few studies have included field observations. The objective of the present study was to evaluate the performance of a novel acoustic dissolved oxygen transmitter for field biotelemetry. The results demonstrated that the output of the transmitter was unaffected by three different temperatures (10 to 30 degrees C) and described the dissolved oxygen saturation with high accuracy (r(2) > 0.99) over the entire range of 0 to 191% saturation. The response time (>= 90% of end value) of the transmitter was 12 s both in terms of decreasing (100 to 0%) and increasing (0 to 100%) oxygen saturations. When externally attached to fishes the present findings support the use of the transmitter for reliable dissolved oxygen measurements on individuals living in environments that may change both temporally and spatially ...
2006-01-01
Uranium Mass and Isotopic Analysis. A new drum tomographic gamma scanning system
Energy Technology Data Exchange (ETDEWEB)
The NIS-6 group at Los Alamos National Laboratory pioneered the development of Tomographic Gamma Scanning and continue to improve its utility in real measurement situations. Building on this experience we report the development of a state of the art TGS system suitable for industrial applications. The image reconstruction and visualization software has been integrated into the familiar Canberra NDA2000 software suite which also handles all other aspects of the data acquisition and management. In this paper we describe the salient design and performance parameters of the system. The application of gamma-ray tomography to safeguards for improved assay accuracy and knowledge confirmation is discussed. In particular we compare and contrast the relative merits of this TGS and a traditional Segmented Gamma Scanner and illustrate how the 3-D visualization of the TGS image can provide valuable additional information.
2003-05-01
Surface analysis by Fourier-transform infrared (FTIR) spectroscopy
Energy Technology Data Exchange (ETDEWEB)
A diffuse-reflectance capability for the Fourier transform infrared spectrometer at the Y-12 Plant Laboratory has been implemented. A sample cell with a 25 to 400/sup 0/C temperature-controlled sample stage and an ultrahigh-vacuum-to-atmospheric pressure gas-handling capability has been developed. Absorbance of light from the spectrometer beam, resulting from the beam being scattered from a powder sample, can be measured. This capability of detecting molecular species on and in powders is to be used to study chemisorption on actinide and rare-earth metals, alloys, and compounds. Cell design is described along with experiments demonstrating its performance in detecting moisture absorption on uranium oxide, moisture and carbon dioxide absorption on the lithium hydride/hydroxide system, and carbon dioxide absorption on potassium borohydride. 13 figures.
1981-08-12
Standardisation of "2"1"0Pb by Cerenkov counting
International Nuclear Information System (INIS)
A standard of "2"1"0Pb in solution was produced at the National Physical Laboratory by a novel technique combining Cerenkov counting with the established liquid scintillation efficiency tracing technique known as the CIEMAT/NIST method. Coincidence counting was applied in order to validate the measurements and the activity concentrations of the solution determined with each technique are shown to be in agreement. Radiochemical separation of the "2"1"0Pb from its daughters was also necessary and the scheme for the separation is described. After performing this two-stage standardisation, the uncertainty was successfully lowered to 0.66% (k=1). This uncertainty is approximately a factor of four lower than previously achieved at NPL by the classical method of standardisation of radionuclides, i.e. coincidence counting.
2011-05-01
Some aspects of concentrated sulphuric acid storage tank corrosion
Energy Technology Data Exchange (ETDEWEB)
Carbon steel is frequently used to construct concentrated sulphuric acid storage tanks. This paper discussed the corrosion performance of carbon steel tanks and outlined the underlying mechanisms responsible for major corrosion modes. Analyses of hydrogen grooving and dilute acid corrosion failure mechanisms were presented. Recent corrosion-induced leak failures were also discussed. The use of anodic protection and organic coatings as a corrosion control measure was also evaluated. The results of laboratory studies that were conducted to understand corrosion-induced failures showed that carbon steel electrodes exhibited transpassive corrosion at relatively high anodic potentials, while stainless steel electrodes exhibited transpassive corrosion at anodic potentials less than 1 V. It was concluded that corrosion-induced leaks can be prevented by using anodic protection and baked phenolic coating technologies. 23 refs., 9 figs.
2009-07-01
Radiation hazard control report
Energy Technology Data Exchange (ETDEWEB)
The radiation control carried out in Atomic Energy Research Institute, Kinki University, for the reactor installation and the tracer/accelerator facilities from April, 1981, to March, 1982, is described. The reactor was operated for total 1057.1 hours at the maximum heat output of 1 W. The persons subject to radiation protection as of April, 1981, were 126 persons in all, including 23 in radiation work and 11 in X-ray work, etc. The contents of this report are as follows: personnel monitoring (health examination, the control of individual exposure dose); laboratory monitoring (the measurement of area dose rate, radioactive concentration in air and water, and surface contamination density); field monitoring (environmental ..gamma..-ray dose rate, radioactive concentration in environmental samples); the use of unsealed radioisotopes, etc.
1982-12-01
Quantitative measurements of injections into porous media with contrast based MRI
British Library Electronic Table of Contents (United Kingdom)
Porous flow occurs in a wide range of materials and applies to many commercially relevant applications such as oil recovery, chemical reactors and contaminant transport in soils. Typically, breakthrough and pressure curves of column floods are used in the laboratory characterization of these materials. These characterization methods lack the detail to easily and unambiguously resolve flow mechanisms with similar effects at the core scale that can dominate at the aquifer or oil field scale, as well as the effects of geometry that control the flow at interfaces as in a perforated well or the inlet of an improperly designed column. Non-invasive imaging techniques such as MRI have been shown to provide a far more detailed characterization of the properties of the solid matrix and flow, but usu...
2011-01-01
Prospects for the direct detection of the cosmic neutrino background
Energy Technology Data Exchange (ETDEWEB)
The existence of a cosmic neutrino background - the analogue of the cosmic microwave background - is a fundamental prediction of standard big bang cosmology. Up to now, the observational evidence for its existence is rather indirect and rests entirely on cosmological observations of, e.g., the light elemental abundances, the anisotropies in the cosmic microwave background, and the large scale distribution of matter. Here, we review more direct, weak interaction based detection techniques for the cosmic neutrino background in the present epoch and in our local neighbourhood. We show that, with current technology, all proposals are still off by some orders of magnitude in sensitivity to lead to a guaranteed detection of the relic neutrinos. The most promising laboratory search, based on neutrino capture on beta decaying nuclei, may be done in future experiments designed to measure the neutrino mass through decay kinematics. (orig.)
2009-01-15
Progress Report Towards the ICANOE Detector
We present a proposal for a combined ICARUS & NOE general purpose detector, to be installed in Hall B of the Gran Sasso Laboratory.The main scientific goal is the one of elucidating in a comprehensive way the pattern of neutrino $9 masses and mixings, following both (1) the S-KAM results and (2) the predictions on atmospheric neutrinos of the large solution of the Solar Neutrinos deficit. To achieve these goals, the experimental method is based upon the $9 complementary and simultaneous detection of CERN beam (CNGS) and cosmic ray (CR) events. This is made possible because of the complete isotropy of the detection technique. For the currently allowed values of the S-KAM results, both $9 CNGS and cosmic ray data will give independent measurements and provide a precise $(sin^{2}2\\theta; \\Delta m^{2})$ determination rather than a wide band of allowed values. Since we can observe and unambiguously identify $9 $\
1999-01-01
Programmable radionuclide X-ray fluorescence multi-channel spectrometric analyzer, type 123-1
International Nuclear Information System (INIS)
The whole equipment consists of three separate portable parts: a detector case, a microprocessor and a graphic TV monitor. Magnetic tape memory and an x-y recorder can be connected for recording the measured spectra. The analyzer contains two built-in exchangeable excitation radionuclides. Fluorescence and scattered radiation is detected using a proportional detector. The detected pulses are analyzed by a 256-channel analyzer and the results are shown on the display. The device may be used in mining laboratories, coal and ore dressing plant control rooms or in mining fields of open cast mines for quick detection of the quality of mined or dressed raw materials. (E.S.). 1 fig.
1988-01-01
Penile Rehabilitation after Radical Prostatectomy: Where Do We Stand and Where Are We Going?
British Library Electronic Table of Contents (United Kingdom)
ABSTRACT Introduction. Postprostatectomy erectile dysfunction (ED) remains a serious quality-of-life issue. Recent advances in the understanding of the mechanism of postprostatectomy ED have stimulated great attention toward penile rehabilitation. Aim. This review presents and analyzes a contemporary series of the recent medical literature pertaining to penile rehabilitation therapy after radical prostatectomy (RP). Main Outcome Measures. The laboratory and clinical studies related to penile rehabilitation are analyzed. The validity of the methodology and the conclusion of the findings from each study are determined. Methods. The published and presented reports dealing with penile rehabilitation following RP in human and cavernous nerve injury in animal models are reviewed. Results. Exciti...
2007-01-01
PHOTON-HADRON INTERACTIONS AT RHIC AND LHC ENERGIES.
Energy Technology Data Exchange (ETDEWEB)
Heavy Ion Collisions at RHIC and LHC energies are potentially an interesting laboratory for the study of QED. In these collisions, a Heavy Ion in one beam sees a highly Lorentz contracted electric field due to an oncoming beam particle. The Electric field reaches a maximum value of E {approx_equal} {gamma}{sub eff} {center_dot} Z {center_dot} e/b{sup 2}, where the apparent Lorentz factor, {gamma}{sub eff} = 2 {center_dot} {gamma}{sub beam}{sup 2} - 1. The collision may be viewed in terms of a flux of photons colliding with a stationary ion target using the equivalent photon approximation, originally introduced by Fermi in 1924. We show that the cross section for Inelastic Electromagnetic Interactions of Heavy Ions are both calculable and have been measured in the first RHIC running period.
2002-03-01
Modeling of lean premixed combustion in stationary gas turbines
Energy Technology Data Exchange (ETDEWEB)
Lean premixed combustion (LPC) of natural gas is of considerable interest in land-based gas turbines for power generation. However, modeling such combustors and adequately addressing the concerns of LPC, which include emissions of nitrogen oxides, carbon monoxide and unburned hydrocarbons, remains a significant challenge. In this paper, characteristics of published simulations of gas turbine combustion are summarised and methods of modeling turbulent combustion are reviewed. The velocity-composition PDF method is selected for implementation in a new comprehensive model that uses an unstructured-grid flow solver. Reduced mechanisms for methane combustion are evaluated in a partially stirred reactor model. Comprehensive model predictions of swirl-stabilised LPC of natural gas are compared with detailed measurements obtained in a laboratory-scale combustor. The model is also applied to industrial combustor geometries. (Author)
1999-07-01
Idaho Explosives Detection System
Energy Technology Data Exchange (ETDEWEB)
The Idaho Explosives Detection System was developed at the Idaho National Laboratory (INL) to respond to threats imposed by delivery trucks potentially carrying explosives into military bases. A full-scale prototype system has been built and is currently undergoing testing. The system consists of two racks, one on each side of a subject vehicle. Each rack includes a neutron generator and an array of NaI detectors. The two neutron generators are pulsed and synchronized. A laptop computer controls the entire system. The control software is easily operable by minimally trained staff. The system was developed to detect explosives in a medium size truck within a 5-min measurement time. System performance was successfully demonstrated with explosives at the INL in June 2004 and at Andrews Air Force Base in July 2004.
2005-12-01
British Library Electronic Table of Contents (United Kingdom)
The purpose of this study was to validate through natural exposure a cut-off level of varicella zoster IgG as protective against infection with varicella zoster virus (VZV). Laboratory testing to determine VZV immune status of pregnant women exposed to varicella is recommended. Quantitative assays are now available which are sensitive and specific. More than 200 consecutive requests for screening in pregnant patients with recent varicella contacts were followed-up by questionnaire. DiaSorin LIAISON and VZV time resolved fluorescence immuno assay (VZV TRFIA) were used to measure VZV antibody level. One hundred fifty out of 209 (72%) questionnaires were returned; 14 patients developed varicella, 129 did not and seven were not known. Patients who had been given VZIG and developed varicella on...
2011-01-01
Exclusive ?0 electroproduction on transversely polarized protons
International Nuclear Information System (INIS)
The exclusive electroproduction of ?0 mesons was studied with the HERMES spectrometer at the DESY laboratory by scattering 27.6 GeV positron and electron beams off a transversely polarized hydrogen target. Spin density matrix elements for this process were determined from the measured production- and decay-angle distributions of the produced ?0 mesons. These matrix elements embody information on helicity transfer and the validity of s-channel helicity conservation in the case of a transversely polarized target. From the spin density matrix elements, the leading-twist term in the single-spin asymmetry was calculated separately for longitudinally and transversely polarized ?0 mesons. Neglecting s-channel helicity changing matrix elements, results for the former can be compared to calculations based on generalized parton distributions, which are sensitive to the contribution of the total angular momentum of the quarks to the proton spin.
2009-08-17
Energy Technology Data Exchange (ETDEWEB)
A number of buildings dating from the 1950s and 1960s were retrofitted with thermal insulation in order to cut energy consumption. This took place within the building competition 'Therma' nitrated by the Federal Ministry of Regional Planning, Building and Town Planning in 1974. Result at that time were so encouraging that now, 15 years later the results were checked again with special attention to the long-term performance of the thermal insulation measures. Laboratory tests prove that the building materials are still in good condition and that humidity has not increased with age. Cracks in the surface plaster of the compound insulation systems occurred at different frequencies and intensities and usually caused by thermal tensions. (BWI).
1992-04-01
Constraining Parity Violation in Gravity with Measurements of Neutron-Star Moments of Inertia
Neutron stars are sensitive laboratories for testing general relativity, especially when considering deviations where velocities are relativistic and gravitational fields are strong. One such deviation is described by dynamical, Chern-Simons modified gravity, where the Einstein-Hilbert action is modified through the addition of the gravitational parity-violating Pontryagin density coupled to a field. This four-dimensional effective theory arises naturally both in perturbative and non-perturbative string theory, loop quantum gravity, and generic effective field theory expansions. We calculate here Chern-Simons modifications to the properties and gravitational fields of slowly spinning neutron stars. We find that the Chern-Simons correction affects only the gravitomagnetic sector of the metric to leading order, thus introducing modifications to the moment of inertia but not to the mass-radius relation. We show that an observational determination of the moment of ...
2009-01-01
International Nuclear Information System (INIS)
Measurements of absolute differential cross sections for H"+-H_2 direct, single-, and double-charge-transfer scattering at 0.5, 1.5, and 5.0 keV are reported at laboratory scattering angles less than 1 degree with an angular resolution of approximately 0.02 degree. The cross sections exhibit deep interference oscillations in single-charge-transfer scattering, but no such oscillations are present in direct and double-charge-transfer scattering. Theoretical cross sections derived using the diatoms-in-molecules method to describe the molecular states in a semiclassical molecular-orbital three-state close-coupling model within a semiclassical framework agree satisfactorily with the experimental results.
CO and CO2 emissions from spontaneous heating of coal under different ventilation rates
British Library Electronic Table of Contents (United Kingdom)
Carbon monoxide (CO) and carbon dioxide (CO2) emissions during a spontaneous heating event in a coal mine are important gases to monitor for detecting the spontaneous heating at an early stage. However, in underground coal mines, the CO and CO2 concentrations and their related fire ratios may be affected by mine ventilation. In this study, CO and CO2 emissions from spontaneous heating of a U.S. coal sample were evaluated in an isothermal oven under different airflow ventilation rates ranging from 100 to 500cm^3/min. Laboratory experiments were conducted at oven temperatures of 70, 90, and 100^oC. The temperature at the center of the coal sample was continually monitored, while the CO, CO2, and oxygen (O2) concentrations of the exit gas were continually measured. The results indicate that C...
2011-01-01
International Nuclear Information System (INIS)
Comparisons of calculated neutron yield distributions from #alpha#-particle induced reactions on thick targets are made with measured data to analyze the initial reaction process in the framework of the exciton (hybrid) model code ALICE91 (M. Blann, Lawrence Livermore National Laboratory Report UCID 19614, 1982). We have considered two reaction mechanisms: dissolution of the #alpha# in the nuclear field, and preequilibrium processes initiated by #alpha#-nucleon collisions. Both these processes seem to contribute to the emitted neutron spectra in varying proportions depending on the incident #alpha# energy and possibly on the target nucleus. Contributions from other processes appear to be non-negligible.
2003-06-01
International Nuclear Information System (INIS)
This paper reports measurements of absolute differential cross sections for electron capture and loss for fast hydrogen atoms incident on H_2, N_2, O_2, Ar, and He. Cross sections have been determined in the 2.0- to 5.0-keV energy range over the laboratory angular range 0.02 degree--2 degree, with an angular resolution of 0.02 degree. The high angular resolution allows us to observe structure at small angles in some of the cross sections. Comparison of the present results with those of other authors generally shows very good agreement.
A Model for Chlorine Dioxide Delignification of Chemical Pulp
British Library Electronic Table of Contents (United Kingdom)
A phenomenon based model for chlorine dioxide delignification of chemical pulp is introduced. The pulp suspension environment is modeled using the concept of two liquid phases, one inside and the other external to the fiber wall. Physico-chemical processes taking place during delignification are implemented with thermodynamic, mass transfer and reaction kinetic models. A broad library of chemical reactions is introduced. Inclusion of each reaction is justified. The model response is tested against experimental laboratory delignification results (o-delignified birch pulp). The experimental data consists of kappa number, hexenuronic acid, inorganic oxy-chlorine compound, and organochlorine (AOX, OX) measurements at several time points during five delignification experiments. The model predic...
2010-01-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
