WorldWideScience
1

Corrosion Brochure - KSC Corrosion Technology Laboratory Home - NASA  

Science.gov (United States)

Specialized tests can be designed to study impingement-corrosion, erosion- corrosion, cathodic protection systems, cavitation and other velocity effects. ...

3

Criteria for the selection of corrosion inhibitors for Arctic and subsea high velocity flowlines  

Energy Technology Data Exchange (ETDEWEB)

Qualifying corrosion inhibitors for use in high velocity multiphase flowlines in arctic or subsea environments is discussed. The tests include high velocity flow loop corrosion tests, pumpability through 0.125 (0.318 cm) inch capillary at low temperatures, compatibility with Nylon 11, emulsion tendency testing, and partitioning characteristics. Laboratory and field data show the importance for using the above criteria for inhibitor selection.

1999-11-01

4

Effectively use corrosion testing  

Energy Technology Data Exchange (ETDEWEB)

The proper selection of materials of construction is necessary to provide process equipment with optimum performance and corrosion resistance. If properly chosen, the selected material should deteriorate at a uniform, predictable rate, which will allow for maintenance or replacement at scheduled intervals. This concept of risk assessment for predictive maintenance is a minimum requirement for proper materials selection. Materials selection is based on prior service history, field corrosion tests, pilot-plant tests, and laboratory bench-top tests--in that relative order of usefulness. Corrosion test methods are usually divided into two groups: laboratory and field (plant-site) tests. The main difference between the two is that field test specimens are exposed ...

1995-04-01

5

FIELD CORROSION TESTS FOR COMPARISON OF ...  

Science.gov (United States)

... Accession Number : ADD457408. Title : FIELD CORROSION TESTS FOR COMPARISON OF CORROSIVITY IN JAPAN AND CHINA. ...

6

Corrosion test and service result of materials used for fuel injection nozzles in marine diesel engines  

Energy Technology Data Exchange (ETDEWEB)

Corrosion test, as a material selection test method of nozzle to be used in the marine diesel engine, was adopted and discussed. Due to the heightening in output power and lengthening in stroke of the marine diesel engine, the fuel injection nozzle became so severe in working condition that the nozzle tip became in lift 1/6 to 1/18 time as long as that of short stroke type in past. Then upon investigating cause of damage, the damage was confirmed to be mainly caused by the high temperature sulfidization corrosion. Then by preparing 20 kinds of candidate test piece and making sulfidization corrosion test in accordance with the high temperature corrosion test procedure, corrosiveness was evaluated through change in weight between before and after testing. As a ...

1989-06-15

7

The effect of flow velocity on pitting corrosion and stress corrosion cracking of reactor materials  

International Nuclear Information System (INIS)

This paper describes two research programs which are currently underway in the author's laboratory to investigate the effect of fluid flow on the degradation of power plant materials in high temperature/high pressure aqueous environments. These programs include the design and operation of a controlled hydrodynamic corrosion testing apparatus that can be used to study the general and localized corrosion characteristics of alloys in simulated nuclear reactor environments, and a study of the effect of flow velocity on the stress corrosion cracking of ASTM A508 C1.2 steel and Type 304SS in simulated BWR heat transport fluids.

8

Corrosion probes for fireside monitoring in coal-fired boilers  

Energy Technology Data Exchange (ETDEWEB)

Corrosion probes are being developed and combined with an existing measurement technology to provide a tool for assessing the extent of corrosion of metallic materials on the fireside in coal-fired boilers. The successful development of this technology will provide power plant operators the ability to (1) accurately monitor metal loss in critical regions of the boiler, such as waterwalls, superheaters, and reheaters; and (2) use corrosion rates as process variables. In the former, corrosion data could be used to schedule maintenance periods and in the later, processes can be altered to decrease corrosion rates. The research approach involves laboratory research in simulated environments that will lead to field tests of corrosion probes in coal-fired boilers. Laboratory research has already shown that ...

2005-01-01

10

Electrochemical noise measurements of sustained microbially influenced pitting corrosion in a laboratory flow loop system.  

Energy Technology Data Exchange (ETDEWEB)

Because of the chaotic nature of the corrosion process and the complexity of the electrochemical noise signals that are generated, there is no generally accepted method of measuring and interpreting these signals that allows the consistent detection and identification of sustained localized pitting (SLP) as compared to general corrosion. We have reexamined electrochemical noise analysis (ENA) of localized corrosion using different hardware, signal collection, and signal processing designs than those used in conventional ENA techniques. The new data acquisition system was designed to identify and monitor the progress of SLP by analyzing the power spectral density (PSD) of the trend of the corrosion current noise level (CNL) and potential noise level (PNL). Each CNL and PNL data point was calculated from the root-mean- square value of the ac components of current and potential fluctuation signals, which ...

1999-01-13

11

Metals and alloys : atmospheric corrosion testing : General requirements for field tests  

CERN Document Server

Metals and alloys : atmospheric corrosion testing : General requirements for field tests

1992-01-01

12

Nickel alloy clad steel plate for flue gas desulfurization applications  

Energy Technology Data Exchange (ETDEWEB)

The use of nickel alloys in Flue Gas Desulfurization (FGD) applications is described. Recently, nickel alloys 625 and C-276 have been clad to carbon steel plate. Production and properties of the clad plate are reviewed and a brief discussion is presented on production, fabrication and welding. Laboratory and field corrosion tests in SO/sub 2/ scrubber environments suggest that alloy 625 and C-276 clad steel plates are as corrosion resistant as the solid alloy plate.

1987-01-01

13

Anodic protection: theory and practice in the prevention of corrosion  

Energy Technology Data Exchange (ETDEWEB)

Theoretical and practical aspects of anodic protection for control of corrosion by a wide range of acidic and alkaline solutions are discussed. Chapters are included concerning strategic importance of metals and alloys in modern industry, applications to industrial equipment, descriptions of equipment used in the technique; design, operation and maintenance; economics, scientific principles, characteristics of potentiostats, laboratory tests and procedures, selected application examples and projected future uses. A section is devoted to electrochemical principles.

1981-01-01

14

A laboratory and field investigation of naphthenic acid corrosion inhibition  

Energy Technology Data Exchange (ETDEWEB)

This paper presents results of a laboratory and field study of naphthenic acid corrosion and the development of an effective chemical inhibitor for this type of corrosive attack. In the laboratory corrosion test, which involved 20 hour weight loss measurements in high flash solvent with a total acid number (TAN) of 16 mg KOH/gm at a temperature of 600 F (316 C), blank corrosion rates averaged 140 to 150 mpy (3.56 to 3.81 mm/y). Inhibited rates averaged about 10 to 12 mpy (0.254 to 0.305 mm/y). The field test was carried out on a heavy vacuum gas oil (HVGO) stream at 550 F (288 C) . Blanks varied from a high of 425 mpy (10.79 mm/y) for a 24 hour test to a low of about 100 mpy (2.54 mm/y) for a 150 hour test. Both electrical resistance (ER) probes and weight loss coupons showed ...

1995-11-01

15

Corrosion studies of carbon steel under impinging jets of simulated slurries of neutralized current acid waste (NCAW) and neutralized cladding removal waste (NCRW)  

Energy Technology Data Exchange (ETDEWEB)

Plans for the disposal of radioactive liquid and solid wastes presently stored in double-shell tanks at the Hanford Site call for retrieval and processing of the waste to create forms suitable for permanent disposal. Waste will be retrieved from a tank using a submerged slurry pump in conjunction with one or more rotating slurry jet mixer pumps. Pacific Northwest Laboratory (PNL) has conducted tests using simulated waste slurries to assess the effects of a impinging slurry jet on the corrosion rate of the tank wall and floor, an action that could potentially compromise the tank's structural integrity. Corrosion processes were investigated on a laboratory scale with a simulated neutralized cladding removal waste (NCRW) slurry and in a subsequent test with simulated neutralized current acid waste (NCAW) slurry. The test slurries ...

1992-01-01

16

Corrosion studies of carbon steel under impinging jets of simulated slurries of neutralized current acid waste (NCAW) and neutralized cladding removal waste (NCRW)  

Energy Technology Data Exchange (ETDEWEB)

Plans for the disposal of radioactive liquid and solid wastes presently stored in double-shell tanks at the Hanford Site call for retrieval and processing of the waste to create forms suitable for permanent disposal. Waste will be retrieved from a tank using a submerged slurry pump in conjunction with one or more rotating slurry jet mixer pumps. Pacific Northwest Laboratory (PNL) has conducted tests using simulated waste slurries to assess the effects of a impinging slurry jet on the corrosion rate of the tank wall and floor, an action that could potentially compromise the tank`s structural integrity. Corrosion processes were investigated on a laboratory scale with a simulated neutralized cladding removal waste (NCRW) slurry and in a subsequent test with simulated neutralized current acid waste (NCAW) slurry. The test slurries simulated the ...

1992-01-01

17

Laboratory studies of gas generation and potential for tank wall corrosion during blending of high-level wastes at the West Valley Demonstration Project  

Energy Technology Data Exchange (ETDEWEB)

Laboratory experiments were conducted to simulate the transfer of acidic THOREX waste from Tank 8D-4 into the alkaline PUREX waste in Tank 8D-2 at West Valley. The purpose of the experiments was to explore means of minimizing the production of nitric oxide (NO) gas during mixing of the two wastes and to assess the potential for the gas to further react in the vapor space possibly leading to enhanced corrosion of the tank walls. Forty one THOREX/PUREX mixing tests were conducted to explore the effects of stirring rate, pH, THOREX addition rate, THOREX or PUREX dilution, and temperature. The two most important criteria for minimizing NO production were to maintain some degree of agitation and the keep the pH in the PUREX high, preferably >12. Steel corrosion tests were performed in the presence of low partial pressures of NO{sub 2} and liquid water or water vapor. The NO{sub 2} ...

1995-05-01

18

Corrosion: Understanding the basics  

Energy Technology Data Exchange (ETDEWEB)

This new book presents a practical how to approach to understanding and solving the problems of corrosion of structural materials. Although it is written mainly for those having a limited technical background in corrosion, it also provides more experienced engineers with a useful overview of the principles of corrosion and can be used as a general guide for developing a corrosion-control program. Contents include: the effects and economic impact of corrosion; basic concepts important to corrosion; principles of aqueous corrosion; forms of corrosion: recognition and prevention; types of corrosive environments; corrosion characteristics of structural materials; corrosion control by proper design; corrosion control by materials selection; ...

2000-07-01

19

Overview of the FRG waste package materials corrosion test program  

International Nuclear Information System (INIS)

Presently in the FRG there are essentially three institutions involved in corrosion experiments related to high level waste package materials, namely KfK-INE, Nukem and Bayer Leverkusen. In 1981 KfK-INE started a corrosion test program aiming at the selection of suitable canister materials for vitrified high level waste. The program encompassed electrochemical investigations, which were concluded in 1984. Moreover field corrosion tests and laboratory experiments were initiated, and are still ongoing. Several possible canister materials such as mild steel, Ti-Pd-alloy, Hastelloy C4 and others were investigated under the influence of varying parameters such as temperature, and radiation. Both Nukem Company and DWK were assigned the responsibility to conceive and develop a cask for the direct final disposal of spent fuel assemblies. Two solution turned out as most ...

1988-03-08

20

Prediction of Corrosion of Advanced Materials and Fabricated Components  

Energy Technology Data Exchange (ETDEWEB)

The goal of this project is to provide materials engineers, chemical engineers and plant operators with a software tool that will enable them to predict localized corrosion of process equipment including fabricated components as well as base alloys. For design and revamp purposes, the software predicts the occurrence of localized corrosion as a function of environment chemistry and assists the user in selecting the optimum alloy for a given environment. For the operation of existing plants, the software enables the users to predict the remaining life of equipment and help in scheduling maintenance activities. This project combined fundamental understanding of mechanisms of corrosion with focused experimental results to predict the corrosion of advanced, base or fabricated, alloys in real-world environments encountered in the chemical industry. At the heart of this approach is the development of models ...

2007-09-29

21

Causes of denting. Volume 5. Contaminant threshold tests. Final report  

Science.gov (United States)

Steam generators in PWR plants have been subject to denting corrosion as a result of nonprotective magnetite forming on the carbon steel support plate causing the voluminous corrosion product that eventually crimps (dents) the heat transfer tube at the support plate interface. This project was designed to determine the causes of denting and the usefulness of water chemistry changes meant to arrest denting. This volume of the final report describes laboratory research on the correlation of water chemistry, superheat, and oxygen ingress with denting in steam generators.

1983-12-01

22

Corrosion of aluminum and copper thin films under simulated atmospheric conditions in laboratory tests  

Energy Technology Data Exchange (ETDEWEB)

Corrosion characteristics of Al and Cu thin films have been studied in cyclic fog tests using tap water fog and fog created with 0.1% NaCl solution in tap water. Likewise, their corrosion features have been analyzed in continuous immersion testing in the laboratory in distilled water, tap water, in 0.1% NaCl and 3.5% NaCl solutions in distilled water. The corrosion potentials and the corrosion currents of these thin films change and reach steady state values after some time. However, steady state is not realized in 3.5% NaCl solutions. The corrosion current density data have been used to calculate lifetime of 1 {mu}m thick thin films of Al and Cu in the various tests, and assuming that the fog test data would hold under normal exposure conditions, life spans for these thin film ...

1998-12-31

23

Laboratory tests of sludge-control additives  

Energy Technology Data Exchange (ETDEWEB)

Laboratory {open_quotes}jar{close_quotes} tests compared eleven different fuel oil and diesel fuel sludge-control additives. Factors studied included (1) ability to disperse and prevent buildup of sludge deposits on surfaces, (2) ability to protect steel from corrosion, (3) ability to inhibit growth and proliferation of bacteria, and (4) ability to disperse water. Results varied greatly, and it was found that many commercial products do not do what they claim. It is concluded that fuel retailers should not believe manufacturers` claims for their additive products, but rather should test such products themselves to be sure that the benefits of treatment are real. A simplified form of the procedure used here is proposed as one way for dealers to do such testing.

1996-07-01

24

Investigations on denting phenomenon in monel tubes  

International Nuclear Information System (INIS)

Denting phenomenon as experienced in PWR steam generators has been investigated in the laboratory of Monel-400 tubes and C-steel baffles combination. Isothermal corrosion tests have been carried out by exposing capsules, containing a crevice between Monel-400 tubes and C-steel plugs, in plausible corrodents at 300"0C. Results indicated that the denting phenomenon is strongly influenced by the chloride content in the solution. In addition, it is a time dependent process. Stress exerted on the tubes by the growth of corrosion product on the outside surface of C-steel plugs are enough to deform the Monel tubes. The results have been discussed on the basis of accelerated corrosion of C-steel by hydrolyzable metal chlorides. (author).

1981-05-01

25

CORROSION RESISTANCE OF CHROMIUM CARBIDE-BASE ...  

Science.gov (United States)

... FIELD CORROSION TESTS WERE MADE DURING THE VOYAGES OF THE SCIENTIFIC-RESEARCH SHIPS ACADEMICIAN VERNADSKII AND ...

26

Materials issues in coal-fired combined cycle power generation systems: laboratory versus plant testing  

Energy Technology Data Exchange (ETDEWEB)

The successful development of coal-fired combined cycle power generation systems require that all component parts are manufactured from appropriate materials and that these materials give predictable in-service performance. High temperature corrosion resulting from coal-derived particulates, deposition and gaseous species, is potentially life limiting for many components in these systems. Realistic laboratory test methods are outlined for gasifier and gas turbine environments and these have been combined with a materials assessment method based on accurate dimensional metrology. Such tests have allowed the production of models of materials performance as well as accurate comparisons between laboratory and plant derived data. These initial models predict the performance of materials well in the gas turbine environment, but tend to under-predict the damage observed in real gasifier ...

1997-12-31

28

Brine chemistry and control of adverse chemical reactions with natural gas production. Annual report, January-December 1984  

Energy Technology Data Exchange (ETDEWEB)

Monitoring brine chemistry to determine the extent of potential adverse reactions was simplified by the development of a field brine test kit and a series of nomographs. Results of the kit analyses serve as input to the nomographs, which provide a graphic means of determining the scaling tendency (Saturation Index value) of a brine. Brines that do not tend to form scale may be corrosive. Saturation Index values have been correlated with various processes using data from geopressured wells in the Gulf Coast area. Control of scale in surface equipment of geopressured wells by chemical inhibitors has been successful. Downhole treatment with inhibitors to prevent scale formation in the production tubing is being investigated. Laboratory simulations indicate that an inhibitor squeeze treatment may be successful at the Gladys McCall No. 1 well. Inhibitor mixtures exhibit additive behavior at minimum concentration levels; however, ...

1985-01-01

29

Some aspects of concentrated sulphuric acid storage tank corrosion  

Energy Technology Data Exchange (ETDEWEB)

Carbon steel is frequently used to construct concentrated sulphuric acid storage tanks. This paper discussed the corrosion performance of carbon steel tanks and outlined the underlying mechanisms responsible for major corrosion modes. Analyses of hydrogen grooving and dilute acid corrosion failure mechanisms were presented. Recent corrosion-induced leak failures were also discussed. The use of anodic protection and organic coatings as a corrosion control measure was also evaluated. The results of laboratory studies that were conducted to understand corrosion-induced failures showed that carbon steel electrodes exhibited transpassive corrosion at relatively high anodic potentials, while stainless steel electrodes exhibited transpassive corrosion at anodic potentials less than 1 V. It was concluded ...

2009-07-01

30

FIELD CORROSION TESTS IN REDOX AND PUREX UNDERGROUND WASTE STORAGE TANKS  

Science.gov (United States)

A corrosion-testing program has been initiated in Purex and Redox storage tnnks to obtain corrosion data on carbon steel and three associated materials in neutralized process wastes. (C.W.H.)

1955-06-28

31

46 CFR 160.171-17 - Approval testing for adult size immersion suit.  

Science.gov (United States)

...visible damage. (k) Corrosion resistance. Each metal part of a...evidence of salt-spray corrosion resistance equal to or greater than...sample of test metal must show corrosion resistance equal to or better than...

2010-10-01

33

Pitting corrosion of welded joints of chromomanganese with nitrogen austenite steel  

International Nuclear Information System (INIS)

The tendency of welded joints from 10Kh14AG15 and 10Kh14AG9 steels to pitting corrosion under the conditions of operating blast-furnace gas purification scrubbers has been investigated. Water in scrubbers contains various quantities of chlorides and sulfates, has pH from 6 to 9 and temperature 65-75 deg. The laboratory corrosion tests have been carried out also on samples turned from the heat-affected zone (h.a.z.) of welded plates at 20 and 65 deg. Anode polarization curves have been read from the Vk corrosion potential at potential shifting rate 0.01 V/min. It is established that in most rigid conditions of scrubbers operating pitting corrosion (PC) rate of chrome-manganese nitrogen-containing steel can reach 2.5 mm/year. At high content of chlorides in water the elevated temperature and external tensile stresses intensify PC. The resistance of welded joints ...

34

The Effect of Morpholine/Boric Acid/Hydrazine Chemistry on ...  

Science.gov (United States)

... the effect of MBH on steam generator crevice corrosion; model boiler test results show that MBH is effective against denting corrosion and Alloy 600 ...

35

INVESTIGATION OF THE CORROSION RESISTANCE OF BS ...  

Science.gov (United States)

... 1. IE1O and IM'15 exposed to field corrosion tests at five sites for periods of 12 and 24 months confirm previous findings. ...

1953-12-01

36

AFSPC Corrosion Control Program - NASA  

Science.gov (United States)

HQ AFSPC/LG / CORR.PPT. 2. 01/16/02. UNCLASSIFIED. UNCLASSIFIED. Overview. " Corrosion Control Areas. " Support Activities. " Test Projects ...

37

Effect of boric acid on steam generator corrosion  

International Nuclear Information System (INIS)

Project RPS116, ''Implementation of Boric Acid in the Field,'' was designed to demonstrate that a selected steam generator boric acid treatment is effective in arresting the progressing of denting in an operating steam generator. The PWR nuclear steam generators chosen for the testing were those at the Indian Point Unit 3 nuclear site. Hydrogen monitoring measurements and eddy current examinations had indicated that the Indian Point Unit 3, Series 44 steam generators had already reached an advanced stage of denting and tube support plate ligament discontinuities were observed. The objective of the boric acid treatment was to reduce the rate of denting by attempting to reproduce in the field the positive results achieved with boric acid in laboratory-simulated denting tests. Laboratory testing has indicated that implementation of a four day low power (25% power) boric acid soak with ...

1985-03-01

38

Brine chemistry and control of adverse chemical reactions with natural gas production. Annual report, January-December 1986  

Energy Technology Data Exchange (ETDEWEB)

Monitoring brine chemistry to determine the extent of potential adverse reactions has been simplified by the development of a field-brine test kit and a series of nomographs. Results of the kit analyses serve as input to the nomographs, which provide a graphic means of determining the scaling tendency (Saturation Index value) of a brine. Brines that do not tend to form scale may be corrosive. Saturation Index values were correlated with various processes using data from geopressured wells in the Gulf Coast area. Control of scale in surface equipment with chemical inhibitors has been successful. Numerous laboratory simulations of inhibitor squeeze operations were completed using core material with calcite present and absent. The corresponding wells were squeezed with phosphorous-containing inhibitors, and the flowback of brine was monitored for phosphorous concentrations vs time. A new procedure to measure the concentration ...

1987-01-01

39

Microbiologically influenced corrosion of carbon and stainless steel pipes; Mikrobiologisch beeinflusste Korrosion an Rohrleitungen aus unlegierten und hochlegierten nichtrostenden Staehlen  

Energy Technology Data Exchange (ETDEWEB)

About ten years ago microbiologically influenced corrosion manifested on stainless steel pipes used with river water for cooling a chemical plant. The pipe material was similar to Type 316 L. After only six weeks of operation pinhole leaks occurred nearly simultaneously at several welded joints of the pipe. The material degradation was simulated in laboratory and field corrosion tests. Microbiologically influenced corrosion failures also appeared on the pipes of a tubular heat exchanger of duplex steel Type 31803 and on carbon and stainless steel pipes in industrial waste water purification plants after these plants had been modernized with a biological purification unit. The basics of microbiologically influenced corrosion phenomena and typical corrosion failures of pipes will be described. (orig.) [German] Vor etwa zehn Jahren sind in ...

1999-09-01

40

Corrosion and indices of operating reliability of steam-water circuits of foreign NPP  

Energy Technology Data Exchange (ETDEWEB)

Corrosion failures in circuits of foreign NPPs are considered. According to American statistics there are more corrosion failures in two-circuit NPPs than in NPPs with one circuit. Steam generators mostly suffer from ''corrosion denting''. Lately pitting corrosion becomes a potentially serious problem. Steam generator vertical tubes are mainly subjected to this corrosion type. Attention is drawn to intercrystalline corrosion. The causes of corrosion are described. The problem of optimization of structural materials is discussed to reduce corrosion failures as well as other methods of decreasing corrosion failures. Organization of nondestructive testing, increased requirements to water and steam purity are of great importance.

1983-12-01

41

Meier associates and Pacific Northwest Laboratory staff exchange: Transfer of corrosion monitoring expertise to assess and develop in-line inspection tools for corrosion control  

Energy Technology Data Exchange (ETDEWEB)

Staff exchanges, such as the one described in this report, are intended to facilitate communication and collaboration among scientists and engineers at DOE laboratories, in US industry, and academia. During the past 5 years, PNL has developed prototype instrumentation to automate the data collection required for electrochemical determination of corrosion rates and behavior of materials in various electrically conductive environments. The last version is labeled the Sentry 100 prototype corrosion data scanner. Applications include these in the pulp and paper industry and at hazardous waste sites.

1995-04-01

42

Pitting corrosion resistance of silicon-implanted stainless steels  

International Nuclear Information System (INIS)

The pitting corrosion resistance of three different types of stainless steel implanted with silicon is investigated using the potentiokinetic polarization technique. The specimens are tested in 3% NaCl and 0.1 N HCl solutions. Silicon ion implantation inhibits pitting corrosion of the steels in both aqueous media. The corrosion resistance depends on the silicon dose. Post implantation annealing only slightly alters the localized corrosion. (author).

43

Effect of aging on the pitting corrosion behavior in Al-Li alloys  

Energy Technology Data Exchange (ETDEWEB)

In the present work, electrochemical measurements and corrosion tests in NaCl solutions were carried out to study the effect of aging treatments on pitting corrosion behavior in a 8090 alloy and its high purity Al-Li binary alloy analogue. The pitting corrosion characteristics and corrosion resistance of the 8090 alloy have been determined in relation to precipitation microstructures. (orig.).

1990-06-01

44

Causes of denting. Volume 1. Summary report. Final report  

Science.gov (United States)

This summary report outlines the work that was performed to gain a more complete understanding of denting corrosion of steam generators in PWRs. Background laboratory and plant data on denting were compiled, reviewed and correlated to determine how various exposure conditions affect denting. Two high-temperature chemistry analytical models were reviewed and evaluated by experimental simulation of impurity concentration in the heat transfer and isothermal capsule tests. Simulation of impurity concentration for three cooling waters (lake, river, and cooling tower) was evaluated. The effects of species concentration (Cu/sup + +/, Cl/sup -/, O/sub 2/, and H/sup +/), contaminant thresholds (established by isothermal and heat transfer tests), and heat flux as indicated by superheat on denting were examined. A discussion of several pertinent observations and conclusions drawn from these tasks (as they pertain ...

1984-05-01

45

Laboratory Evaluation of an Electrochemical Noise System for Detection of Localized and General Corrosion of Natural Gas Transmission Pipelines  

Energy Technology Data Exchange (ETDEWEB)

Gas transmission pipelines are susceptible to both internal (gas side) and external (soil side) corrosion attack. Internal corrosion is caused by the presence of salt laden moisture, CO{sub 2}, H{sub 2}S, and perhaps O{sub 2} in the natural gas. Internal corrosion usually manifests itself as general corrosion. However, the presence of chlorides in entrained water also can lead to pitting corrosion damage. The electrochemical noise technique can differentiate general from localized corrosion and provide estimates of corrosion rates without external perturbation of the corroding system. It is increasingly being applied to field and industrial installations for in situ corrosion monitoring. It has been used here to determine its suitability for monitoring internal and external corrosion damage on gas ...

2003-03-16

46

Assessment of degradation processes in corrosion resistant steels in nuclear power engineering  

International Nuclear Information System (INIS)

The possible corrosion damage is discussed of the CrNi and CrNiMo types steels used as structural materials in WWER type nuclear power plants. It includes point and slot corrosion, corrosion cracking and corrosion fatigue as well as corrosion denting. Also discussed are test procedures that simulate operating conditions and are used for assessing the properties of metallurgical products (sheets and tubes) used in nuclear power engineering. Briefly described is a system for testing the said products in an aqueous medium while keeping the test parameters in a narrow range for a long time. Under the defined temperature, pressure and corrosion medium composition, the test specimens in this system can mechanically be loaded, both statically and dynamically or a temperature gradient ...

1987-12-01

47

Current status and future plan of JMTR Hot Laboratory  

Energy Technology Data Exchange (ETDEWEB)

The newly developed techniques by the Hot Laboratory (JMTR HL) have provided for us the key information on behavior of specimens due to mechanical / physical / chemical / synergistic effects of radiation, stress and water for fission and fusion reactor environment. These techniques are focused on several topics as follows; (1) miniaturized specimen test for the development of fusion reactor materials, (2) slow strain rate tensile testing (SSRT) and crack propagation measuring tests for the study of Irradiation Assisted Stress Corrosion Cracking (IASCC) of core internals of LWR, (3) handling technique on specimens including tritium for the research and development of tritium breeders and neutron multiplier as fusion blanket materials, (4) joining method using the Tungsten Inert Gas (TIG) welding technique for re-assembling of capsule and re-fabrication of specimen and (5) ...

1999-08-01

48

Corrosion of support materials  

International Nuclear Information System (INIS)

Results from a heavily fouled 19 tube C-E model boiler test to investigate the potential for egg crate corrosion in aggressively fouled AVT chemistry are reported. Substantial support plate and egg crate corrosion was produced in this test. Carbon steel drilled support plates exhibited extensive denting which resulted in flow hole ligament cracking. Corrosion of the carbon steel egg crate, through-wall at areas of tube contact, resulted in denting of the Alloy 600 heat transfer tubes. Corrosion performance of the 409 stainless steel egg crate was improved compared to the carbon steel egg crate although localized through-wall corrosion was noted. The results from the above test and previously reported tests were compared based on the following simplifying assumptions: maximum dent size and/or ...

1985-03-01

49

Corrosion of gold bridgewire in electronic components  

Energy Technology Data Exchange (ETDEWEB)

Accelerated aging tests on gold bridgewired detonator assemblies to determine compatibility of the Au and Pd-In-Sn solder with the organic explosive, PENT, have revealed an unusual corrosion process. These tests, conducted at 74/sup 0/C and 54/sup 0/C indicated a preferential attack of the gold. A matrix of corrosion test units was established to study this corrosion problem with accelerating temperatures up to 100/sup 0/C. Scanning electron microscopy (SEM), energy dispersive x-ray (EDX), and x-ray diffraction techniques were used to determine the extent of the corrosion and identify the corrosion products. Results indicate the preferential attack of the gold was due to HCN formed by decomposition of the explosive powder (PETN) at high temperatures. Other associated reactions were also observed including subsequent ...

1986-01-01

50

An evaluation of corrosion resistant alloys by field corrosion test in Japanese refuse incineration plants  

Energy Technology Data Exchange (ETDEWEB)

As the first step for development of the corrosion resistant superheater tube materials of 500 C, 100 ata used in high efficient waste-to-energy plants, field corrosion tests of six conventional alloys were carried out at metal temperatures of 450 C and 550 C for 700 and 3,000 hours in four typical Japanese waste incineration plants. The test results indicate that austenitic alloys containing approximately 80 wt% [Cr+Ni] show excellent corrosion resistance. When the corrosive environment is severe, intergranular corrosion of 40{approximately}200 {micro}m depth occurs in stainless steel and high alloyed materials. It is confirmed quantitatively that corrosion behavior is influenced by environmental corrosion factors such as Cl concentration and thickness of deposits on tube surface, metal temperature, ...

1995-12-01

51

An evaluation of corrosion resistant alloys by field corrosion test in Japanese refuse incineration plants  

International Nuclear Information System (INIS)

As the first step for development of the corrosion resistant superheater tube materials of 500 C, 100 ata used in high efficient waste-to-energy plants, field corrosion tests of six conventional alloys were carried out at metal temperatures of 450 C and 550 C for 700 and 3,000 hours in four typical Japanese waste incineration plants. The test results indicate that austenitic alloys containing approximately 80 wt% [Cr+Ni] show excellent corrosion resistance. When the corrosive environment is severe, intergranular corrosion of 40#approx#200 microm depth occurs in stainless steel and high alloyed materials. It is confirmed quantitatively that corrosion behavior is influenced by environmental corrosion factors such as Cl concentration and thickness of deposits on tube surface, metal temperature, and flue ...

1995-03-26

52

Experimental Evaluation of Tude Support Plate Crevice Chemistry  

Energy Technology Data Exchange (ETDEWEB)

A test methodology for measuring temperature, impedance, pH, and electrochemical potential distributions within a sludge-packed tube support plate crevice in a laboratory test is described. The method successfully showed that there were large concentration gradients between the tube and tube support plate sides of the crevice. The testing also showed that strong bases concentrated more effectively than strong acids, and that the crevice pH, when exposed to seawater-based solutions, increased with increasing superheat and decreasing bulk concentration. The large variations in the crevice chemistry observed under heat transfer were eliminated upon shutdown. These new test data suggest that it might be beneficial to evaluate the variation in the extent of stress corrosion cracking with tube support plate elevation found in some steam generators in light of local ...

2001-05-08

53

The use of different techniques for determination of pitting corrosion potential of austenitic stainless steel  

International Nuclear Information System (INIS)

Three different techniques for pitting corrosion potential measurement on austenitic stainless steel (Fe18Cr10Ni) were compared: conventional polarization method, a new Avesta electrochemical corrosion measurement cell and a scratch technique. Special attention was paid to the effects of crevice corrosion during pitting corrosion potential measurement and to their elimination. Development of a rapid test technique for reliable pitting corrosion potential determination was aimed at and resulted from comparison of the different techniques.

1991-07-01

54

Evaluation of the corrosion and corrosion-mechanical damage of the primary piping material of WWER-440/V213c units in operating conditions  

International Nuclear Information System (INIS)

The sensitivity of the primary circuit material was examined at the Mochovce and Dukovany NPPs. No significant sensitivity of the base material or the weld metal to the initiation of corrosion cracking was observed. Thermal aging was found to accelerate significantly the corrosion fatigue kinetics in the material of the heat affected zone. The threshold values of the double amplitudes of the stress intensity factor were below 8 MPa/m"2 for the materials examined, with a cycle asymmetry coefficient of 0.65. The tests revealed no appreciable sensitivity to general corrosion, pitting, or intergranular corrosion. (J.B.). 7 tabs., 26 figs., 11 refs.

55

SALT WATER CORROSION TEST OF ROLLING SURFACE ...  

Science.gov (United States)

... by the Bureau. A canvas of supply sources produced only one other, the Flexo roller bearing swivel. Accordingly, only the ...

1955-04-04

56

RESULTS ON INCOLOY 800 AND ALLIED STEAM ...  

Science.gov (United States)

... Title : RESULTS ON INCOLOY 800 AND ALLIED STEAM GENERATOR MATERIALS IN FLORIDA FIELD CORROSION TESTS,. ...

57

Effect of chloride concentration and pH on pitting corrosion of waste package container materials  

Energy Technology Data Exchange (ETDEWEB)

Electrochemical cyclic potentiodynamic polarization experiments were performed on several candidate waste package container materials to evaluate their susceptibility to pitting corrosion at 90 degrees C in aqueous environments relevant to the potential underground high-level nuclear waste repository. Results indicate that of all the materials tested, Alloy C-22 and Ti Grade-12 exhibited the maximum corrosion resistance, showing no pitting or observable corrosion in any environment tested. Efforts were also made to study the effect of chloride ion concentration and pH on the measured corrosion potential (Ecorr), critical pitting and protection potential values.

1996-12-01

58

Growth model and on-line measurement of pitting corrosion on carbon steel  

Energy Technology Data Exchange (ETDEWEB)

A growth model of pitting corrosion of carbon steel in cooling water systems was developed on microscopic observations of pits and electrochemical studies. Results of pitting corrosion measurements in laboratory and field conditions with the model, using a newly developed electrochemical device, are discussed. For an actual heat exchanger up to a year operation, the values of pitting depth estimated were in good agreement with the measured values.

1996-12-01

59

Corrosion experiments and materials developed for the Japanese HLM systems  

British Library Electronic Table of Contents (United Kingdom)

The static corrosion tests in lead-bismuth eutectic (LBE) were conducted from 450degreeC to 600degreeC to understand corrosion behavior and develop corrosion resistant materials for heavy liquid metal systems. While increase of Cr content in steels enhances corrosion resistance in LBE, the effect approaches a constant value above 12wt% of Cr. Corrosion depth in LBE increases with increasing temperature and corrosion attack becomes severe above 550degreeC even under the condition of high oxygen concentration. Nickel dissolution and Pb-Bi penetration occur in 316SS and JPCA above 550degreeC under the condition of high oxygen concentration. When oxygen concentration decreases below the level of Fe oxide formation, corrosion attack on these steels also becomes violent due to dissolution of var...

2011-01-01

60

The estimation of lifetime distribution of Alloy 800 steam generator tubing  

Energy Technology Data Exchange (ETDEWEB)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors worldwide and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under appropriate operating conditions. In planning refurbishment of nuclear plants stations, a key concern is the longevity of existing SGs up to the 60-year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and refines its estimation based on data specific to CANDU operating conditions. The paper presents a more advanced Bayesian probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of ...

2009-10-15

61

The estimation of lifetime distribution of Alloy 800 steam generator tubing  

International Nuclear Information System (INIS)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors worldwide and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under appropriate operating conditions. In planning refurbishment of nuclear plants stations, a key concern is the longevity of existing SGs up to the 60-year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and refines its estimation based on data specific to CANDU operating conditions. The paper presents a more advanced Bayesian probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of ...

2009-10-01

62

A probabilistic approach to the estimation of lifetime distribution of Alloy 800 SG tubing  

Energy Technology Data Exchange (ETDEWEB)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. In planning refurbishment of CANDU stations, a key concern is the longevity of existing SGs up to the 60 year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and estimates it based on experimental data specific to CANDU operating conditions. The paper presents a more advanced probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of degradation ...

2008-07-01

63

A probabilistic approach to the estimation of lifetime distribution of Alloy 800 SG tubing  

International Nuclear Information System (INIS)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. In planning refurbishment of CANDU stations, a key concern is the longevity of existing SGs up to the 60 year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and estimates it based on experimental data specific to CANDU operating conditions. The paper presents a more advanced probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of degradation ...

2008-06-01

64

Performance evaluation of corrosion probes in simulated WVNS tank 8D-2 waste: WVNS tank farm process support  

Energy Technology Data Exchange (ETDEWEB)

Five corrosion probes were received from West Valley Nuclear Services for evaluation in simulated tank 8D-2 3rd-stage sludge wash slurry. The same waste slurry simulated was also used in a series of ongoing corrosion studies assessing the effects of in-tank sludge washing on the integrity of tank 8D-2. Two of the corrosion probes were installed in the coupon corrosion test vessels operating at {approximately}150{degrees}F to compare performance of the probes with that observed by coupon tests conducted in the same vessels. Corrosion rate data calculated from electrical resistance measurements of the corrosion probes were evaluated for this study using two slightly different approaches. One approach uses the total length of exposure of the probe to give a ``time-averaged`` value of the corrosion rate. ...

1994-07-01

65

Research on pitting corrosion of steam generator heat transfer tubes based on acoustic emission  

International Nuclear Information System (INIS)

Corrosion of steam generator heat transfer tubes (SGHTT) is one of the important problems which affect safety operation of nuclear power plants (NPP), and the hazard of pitting corrosion of heat transfer tubes is the most serious. With an acoustic emission device, the signals during a corrosion test on SGHTT were collected and analyzed, and the corrosion points in the tubes were located accurately. The results show that pitting corrosion of heat transfer tubes has passed through three periods in its development: expansion phase, stationary phase and rapid developing phase. The corrosion damage of HTT can be found earlier with acoustic emission than any other non-destructive testing methods. Acoustic emission can be used for on-line and real-time monitoring of the safety and operation of the steam generator and has ...

2010-09-01

66

Corrosion mode diagrams for alloy 690 TT and alloy 800  

Energy Technology Data Exchange (ETDEWEB)

Due to the well-establish corrosion problems of Alloy 600 as a steam-generator material and the subsequent focus on thermally treated (TT) Alloy 690 and Alloy 800 as alternative materials, a systematic analysis of the corrosion behavior of these two latter alloys is warranted. Corrosion test results for Alloys 690 TT and 800 were collected and organized in the form of corrosion mode diagrams. Selected data for mill annealed (MA) Alloy 600 were also included for reference. The corrosion mode diagrams correlate the modes of corrosion degradation observed in tests as functions of the environment pH and electrochemical potential (ECP). The diagrams confirm that Alloys 690TT shows some susceptibility in caustic environments, and Alloy 800 shows susceptibility in both caustic and highly acidic environments. (authors). 6 figs., ...

1994-12-31

67

Corrosion mode diagrams for alloy 690 TT and alloy 800  

International Nuclear Information System (INIS)

Due to the well-establish corrosion problems of Alloy 600 as a steam-generator material and the subsequent focus on thermally treated (TT) Alloy 690 and Alloy 800 as alternative materials, a systematic analysis of the corrosion behavior of these two latter alloys is warranted. Corrosion test results for Alloys 690 TT and 800 were collected and organized in the form of corrosion mode diagrams. Selected data for mill annealed (MA) Alloy 600 were also included for reference. The corrosion mode diagrams correlate the modes of corrosion degradation observed in tests as functions of the environment pH and electrochemical potential (ECP). The diagrams confirm that Alloys 690TT shows some susceptibility in caustic environments, and Alloy 800 shows susceptibility in both caustic and highly acidic environments. (authors). 6 figs., ...

68

The influence of yttrium (Y) on the corrosion of Mg-Y binary alloys  

International Nuclear Information System (INIS)

Research highlights: #-># The Y-intermetallic can accelerate corrosion and Y can increase the protectiveness of the surface layer. #-># In 0.1 M NaCl, the corrosion rate of Mg-Y alloys increased with increasing Y due to the Y intermetallic. #-># In 0.1 M NaCl, there was filiform corrosion. #-># In 0.1 M Na_2SO_4, the corrosion rate of Mg-Y alloys decreased with increasing Y in the range 3-7%Y. #-># Hydrogen evolution was observed from particular parts of the alloy surface. - Abstract: Corrosion of Mg-Y alloys was studied using electrochemical evaluations, immersion tests and direct observations. There were two important effects. In 0.1 M NaCl, the corrosion rate increased with increasing Y content due to increasing amounts of the Y-containing intermetallic. In 0.1 M Na_2SO_4, the corrosion rate decreased ...

2010-11-01

69

Pitting corrosion of copper coiled tubes in the air conditioning system having the open heat storage water tank; Kaihokei chikunetsuso reionsuika ni okeru kuchokiyo kokan no koshoku ni tsuite  

Energy Technology Data Exchange (ETDEWEB)

In order to investigate pitting corrosion of copper coiled tubes for air conditioning systems with an open heat storage water tank, the effect of carbon films on the inner surface of copper tubes and fine corrosion-product particles in water as environmental corrosion factor on pitting corrosion was studied by field test under real environmental conditions. As a result, pitting corrosion of copper tubes was caused by synergistic effect of fine corrosion-product particles in water and carbon films. Generation of pitting corrosion was derived from deposition of the films and particles, while considerable growth of pitting corrosion was dependent on the particles. Time variation of spontaneous electrode potential also showed the effect of the film and particle. Pitting corrosion ...

1998-11-15

70

Corrosion of Cu-W condensates in tap water  

International Nuclear Information System (INIS)

Corrosion resistance of Cu-W system condensates in tap water was studies. It is shown that with an increase in W concentration in the condensates of the Cu-W system their corrosion in tap water enhances. In the material designated for power supply facilities the optimal tungsten content is up to 6%. Owing to formation of oxide film on the surface of the samples corrosion is stabilitized 40 h after the test start.

71

Comparison of Ceramic, Metal and Polymer Crevice Formers on the Crevice Corrosopn Behavior of Ni-CR-Mo Alloy C22  

Energy Technology Data Exchange (ETDEWEB)

A necessary condition for crevice corrosion is that a crevice former create a sufficiently tight, restricted geometry on the metal surface to support the development of critical crevice chemistry. Crevice corrosion is affected by the crevice geometry (tightness) and the properties of the crevice former. The objective of this study is to determine the effect of the crevice former material on the evolution of localized corrosion-damage. A standard crevice corrosion test method is modified by (a) the use of ceramic, metal or polymer materials as the crevice former and (b) the variation of size and shape of the crevice. This study focuses on the post initiation stage of crevice corrosion and addresses factors that may limit the initiation of localized corrosion and also slow or stop the continued propagation of corrosion. ...

2006-05-08

72

Effect of tungsten on the corrosion behavior of sulfuric acid-resistant steels for flue gas desulfurization system  

British Library Electronic Table of Contents (United Kingdom)

Flue gas desulfurization systems (FGDs) are operated in severely corrosive environments that cause sulfuric acid dew-point corrosion. The corrosion behavior of low-alloy steels was tested using electrochemical techniques (electrochemical impedance spectroscopy, potentiodynamic tests, potentiostatic tests), and the corrosion products were analyzed by scanning electron microscopy and X-ray photoelectron spectroscopy. The electrochemical results showed that alloying W with small amounts of Sb, Cu, and Co improves the corrosion resistance of steels. The results of surface analyses showed that the surface of the steels alloyed with W consisted of W oxides and higher amounts of Sb and Cu oxides. This suggests that the addition of W promotes the formation of a protective WO3 film, in addition to ...

2011-01-01

73

Corrosion resistance of zinc coatings on depleted uranium and uranium alloys  

Energy Technology Data Exchange (ETDEWEB)

Simulated atmospheric corrosion studies were performed to determine the corrosion protection provided by galvanized zinc coatings on depleted uranium, U-0.75 Ti alloy, and U-6 Nb alloys. The accelerated ASTM tests consisted of exposing the galvanized samples to aqueous and aqueous chloride environments. The test results showed that anodic protection was provided by the electronegative zinc coatings on uranium and uranium alloys. Treating zinc with chromate conversion coatings also provided more protection.

1985-01-27

74

Corrosion resistance of oxide scale formed on SiSiC in boiling sulfuric acid  

International Nuclear Information System (INIS)

SiSiC is one of selected materials for the thermal chemical hydrogen production IS (Iodine-Sulfur) process at JAERI. SiSiC was tested in boiling sulfuric acid for 1000 hours. The obtained results showed the following facts. The transverse strength was not changed by sulfuric corrosion, high temperature oxidation and oxidation. Silica scale formed on SiSiC by sulfate corrosion and high temperature oxidation had corrosion resistance in boiling sulfuric acid. Bilayer structure of silica scale produced by high temperature oxidation was not affected by sulfate corrosion. (S.Y.).

75

Environmentally assisted cracking in light-water reactors: Semi-annual report, January--June 1997. Volume 24  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes work performed by Argonne National Laboratory on fatigue and environmentally assisted cracking (EAC) in light water reactors from January 1997 to June 1997. Topics that have been investigated include (a) fatigue of carbon, low-alloy, and austenitic stainless steels (SSs) used in reactor piping and pressure vessels, (b) irradiation-assisted stress corrosion cracking of Types 304 and 304L SS, and (c) EAC of Alloys 600 and 690. Fatigue tests were conducted on ferritic and austenitic SSs in water that contained various concentrations of dissolved oxygen (DO) to determine whether a slow strain rate applied during various portions of a tensile-loading cycle is equally effective in decreasing fatigue life. Slow-strain-rate-tensile tests were conducted in simulated boiling water reactor (BWR) water at 288 C on SS specimens irradiated to a low fluence in the Halden reactor and the results ...

1998-04-01

76

The utilization of non-destructive method for in-service inspections in nuclear power components  

International Nuclear Information System (INIS)

To ensure safe and reliable power production nuclear power plants must be operated at high level. Non destructive in-service inspections are inseparable part of the effort. Non destructive in-service inspections are essential on the ground of degradation mechanisms existence in nuclear power components. Degradation processes are constituent of operation of each industrial installation including nuclear power plants. Mission of non-destructive testing is degradation detection, closer characterization of its parameters (dimensions) and to supply as much information as possible to nuclear power plant operator. Eddy current testing method can be assigned to surface - volumetric methods. Method enables inspection of electrically conductive materials. It is particularly suitable for inspection of non-ferromagnetic materials like austenitic stainless steel and brass. The method is used for detection of stress corrosion cracking, ...

2006-01-01

77

Influence of silicon, copper and cobalt on corrosion cracking and pitting corrosion in 03Kh18N30 steel  

International Nuclear Information System (INIS)

The effect of alloying low carbon 18Cr-30Ni steel with silicon (up to 5.1%), copper (up to 5.4%), cobalt (up to 15.3%) on the resistance to corrosion cracking and pitting corrosion, is studied. Tests on uniaxial tension are carried out in 42% MgCl_2 solution and gravimetric studies in 10% FeCl_3x6H_2O. It is established that alloying steel of the Kh18N30 type with silicon increases strength and resistance to corrosion cracking. Copper and cobalt decrease a resistance to pitting corrosion but somewhat increase a resistance to corrosion cracking.

78

Corrosion resistance of materials of construction for high temperature sulfuric acid service in thermochemical IS process. Alloy 800, Alloy 600, SUSXM15J1 and SiC  

International Nuclear Information System (INIS)

Exposure tests of candidate materials were carried out up to 1000 hr in the sulfuric acid environments of thermochemical hydrogen production IS process, focusing on the corrosion of welded portion and of crevice area. In the gas phase sulfuric acid decomposition condition at 850degC, welded samples of Alloy 800 and of Alloy 600 showed the same good corrosion resistance as the base materials. In the boiling condition of 95 wt% sulfuric acid solution, test sample of SiC showed the same good corrosion resistance. Also negligible corrosion was observed in crevice corrosion. (author)

2006-07-01

79

Corrosion resistance in magnesium alloys and deposition coated magnesium alloy  

Energy Technology Data Exchange (ETDEWEB)

Corrosion behavior of deposition coated specimens prepared by the technique proposed by the authors is investigated in salt immersion tests, and also those of pure magnesium, 3N, 4N and 6N grades, and magnesium alloys, AZ31 and AZ91E, are investigated for comparison. Inhomogeneous corrosion occurs in AZ31 and AZ91E alloys when buffered solutions with pH values of 6.5 and 9.0 including 1% NaCl and a conventional 3% NaCl solution are used for immersion tests, while 6N-Mg shows homogeneous corrosion in such solutions. Corrosion behavior of the deposition coated specimen resembles that of 6N-Mg. Purification process included in the deposition coating technique provides homogeneity in microstructural and electrochemical terms, which results in improving corrosion resistance. (orig.)

2003-07-01

80

Sodium hideout studies in steam generator crevices  

International Nuclear Information System (INIS)

The steam generator availability is one of the important problems encountered during the pressurized water nuclear plant operation. Various kinds of corrosion phenomena were observed in the past. These phenomena result from the concentration of impurities mainly in three locations in the steam generators: the tubesheet crevices, the tube support plate crevices, and the sludge pile. Corrections were made in the design and the materials used but a number of steam generators suffer or will suffer from corrosion processes inducing in many cases forcing their replacement. In order to prevent or to retard the corrosions several laboratories have performed experiments to reproduce and to study the corrosion processes. The first step of the degradation is the concentration of chemical species. A method using /sup 24/Na as a radioactive tracer was used to establish the concentration kinetics ...

81

Effects of oxygen, copper and acid chlorides on denting corrosion  

Energy Technology Data Exchange (ETDEWEB)

The effect of dissolved oxygen and copper on denting corrosion at 280/sup 0/C in solutions of NaCl at pH 9 with ammonia was investigated using a packed tube/support plate crevice in a laboratory simulation. The onset of corrosion was detected with a hydrogen analyzer sensitive to 0.2 ppB. In the absence of copper, rapidly rising hydrogen concentrations were detected only when the product of the chloride and oxygen concentrations were detected only when the product of the chloride and oxygen concentrations in the boiler-water exceeded 25 (ppM)/sup 2/, but at these high concentrations, unheated low-carbon steel surfaces in the system were as sensitive to corrosion as the heated crevice. When copper metal was present in the feed system, corrosion of the heated crevice occurred in the absence of oxygen, provided the copper had previously been exposed to dissolved oxygen. Dosing ...

1986-07-01

82

Accelerated aging corrosion tests for buried metal structures  

Energy Technology Data Exchange (ETDEWEB)

It is necessary to identify those measurable soil parameters which dictate the severity of the corrosion problem for coated irons and steels. When this is done, meaningful accelerated aging tests can be designed to validate the reduced corrosion rate for the planned coating. The following discussion introduces the important concepts and measurement parameters in the (a) design of accelerated aging tests, and (b) evaluation of the planned installation site for corrosion potential. Certain combinations of soil oxidation reduction potential (ORP) or electric potential (Eh), acidity (pH), fertilizer, water table, and soil hydraulic conductivity can result in severe corrosion of buried steel/iron vessels. If there are power lines nearby, additional loss of vessel material to the soil will occur. These factors are discussed.

1996-10-01

83

Corrosion resistance of austenitic steels and alloys in high temperature water  

International Nuclear Information System (INIS)

An ampoule corrosion tests technique is presented for making a comparative corrosion-proof estimation of austenitic steels and alloys which are candidate materials for the ITER first wall and shield blanket. Influence of Cl"- on the rate and character of corrosion cracking has been determined. The dependence of time before destruction on Cl"- contents was obtained by experiments in twice-distilled water at a Cl"- content value of less than 0.05 mg/l. Kinetics of a corrosion crack growth has been determined by way of acoustic emission and measurement of electrical resistance. It has been revealed, that corrosion cracking of 316L and 316Ti steels in water with 100 mg/l of Cl"- takes place at temperatures over 50 C. For 316L (Russian analogue), 316Ti, 08Cr18Ni10Ti (type 304), 00Cr16Ni15Mo3Nb (type 316) steels and CrNiMo-1 (42-47%Cr, 1%Mo, Ni-base) alloy ...

84

Corrosion studies on selected packaging materials for disposal of high level wastes  

International Nuclear Information System (INIS)

In order to qualify corrosion resistant materials for high level waste (HLW) packagings acting as a long-term barrier in a rock salt repository, the corrosion behaviour of the preselected materials Ti 99.8-Pd, Hastelloy C4 and two unalloyed steels was investigated. The resistance of the materials to general corrosion, local corrosion and stress corrosion cracking was examined under postulated accident conditions in the repository by long-term immersion tests of up to 4 years duration and electrochemical methods. The parameters investigated were different salt brines, temperatures of 90 deg. C, 170 deg. C and 200 deg. C as well as a gamma radiation field of 10"3Gy/h (10"5rad/h). Among the materials studied, Ti 99.8-Pd exhibited the highest corrosion resistance. This material corroded at a very low rate (

1987-05-01

85

Electrochemical roles of precipitates on uniform corrosion and hydrogen pickup of zirconium alloys, 1. Roles on corrosion  

Energy Technology Data Exchange (ETDEWEB)

Substantial roles of precipitates such as Zr-Fe-Cr type intermetallic compounds on uniform corrosion and hydrogen pickup of zirconium alloys in pure water autoclave tests were investigated from an electrochemical point of view. This paper describes the roles on corrosion. A corrosion test on precipitate-containing and precipitate-free materials made from pure zirconium and a small quantity of iron and chromium, rest potential measurements on an intermetallic compound of Zr(FeCr){sub 2} and zirconium matrix, and a galvanic coupling test of those were performed. Results showed that corrosion behavior of zirconium alloys could be attributed to the electrochemical properties of intermetallic compounds precipitated in each alloy. Namely, the cathodic and anodic polarization characteristics were associated with anodic protection provided by the ...

2000-07-01

86

Electrochemical roles of precipitates on uniform corrosion and hydrogen pickup of zirconium alloys, 1. Roles on corrosion  

International Nuclear Information System (INIS)

Substantial roles of precipitates such as Zr-Fe-Cr type intermetallic compounds on uniform corrosion and hydrogen pickup of zirconium alloys in pure water autoclave tests were investigated from an electrochemical point of view. This paper describes the roles on corrosion. A corrosion test on precipitate-containing and precipitate-free materials made from pure zirconium and a small quantity of iron and chromium, rest potential measurements on an intermetallic compound of Zr(FeCr)_2 and zirconium matrix, and a galvanic coupling test of those were performed. Results showed that corrosion behavior of zirconium alloys could be attributed to the electrochemical properties of intermetallic compounds precipitated in each alloy. Namely, the cathodic and anodic polarization characteristics were associated with anodic protection provided by the ...

2000-07-01

87

Effect of Glycoletherdiaminetetraacetic acid on corrosion inhibition of stainless steel. Glycoleetherdiamin shisakusan ni yoru stainless ko no fushoku yokusei koka  

Energy Technology Data Exchange (ETDEWEB)

An analysis was made on corrosion suppression mechanism of glycoletherdiaminetetraacetic acid (GEDTA) film made from GEDTA on stainless steel, and its corrosion inhibition effect. Results of analysis using IR spectrum, IR-ATR spectrum, {sup 1} HNMR spectrum, and ESCA spectrum indicated the deposition of the GEDTA film is a chemical deposition. In polarization tests at pH = 5 and 7, both polarization curves shifted to the constant current density side, showing suppression effect in reactions at both pH. When the corrosion environment is made severer, such as to pH = 2 and 4, the corrosion suppression effect of GEDTA became more distinctive. A ferroxyl test identified very little difference between untreated and treated materials. In a chemical pitting test, because oxidant and corrosive anion coexist in the ...

1990-12-20

88

Characterization of tube support alloys  

International Nuclear Information System (INIS)

The involvement and relationship of carbon steel corrosion products in the tube denting phenomenon promoted an intensive research effort to: 1) understand, reproduce, and arrest the denting process, and 2) evaluate alternative tube support materials to provide additional corrosion resistance. The paper summarizes a corrosion testing program for the verification of type 405 stainless steel under acid or all volatile treatment conditions.

1985-03-01

89

Corrosion behavior of sputter-deposited W-Nb alloys in NaCl and NaOH solutions  

International Nuclear Information System (INIS)

The corrosion behavior of the sputter-deposited amorphous or nanocrystalline W-Nb alloys is studied in 10% NaCl, 0.1 and 1 M NaOH solutions at 24 deg. C, open to air using immersion tests and electrochemical measurements. Niobium metal acts synergistically with tungsten in enhancing the corrosion resistance of the W-Nb alloys so as to show lower corrosion rates than the corrosion rates of the alloy-constituting elements in almost all examined solutions. Corrosion rates of W-Nb alloys are about more than one order of magnitude less than that of the sputter-deposited tungsten and even lower than that of sputter-deposited niobium. The stability of the anodic passive films formed on the W-Nb alloys increase with niobium content.

2008-05-29

90

Field corrosion tests for a low chromium steel carried out at superheater area of a utility boiler with three coals containing different chlorine contents  

Energy Technology Data Exchange (ETDEWEB)

Field corrosion tests for a low chromium steel were carried out at a superheater area of a 100 MW pulverized coal-fired boiler for various times up to 500 h, when three coals having different chlorine contents were combusted. The low chromium steel had obvious metal loss due to corrosion, and comparison of the metal loss and corrosion scale structure was made among the three coals in respect to chlorine contents as well as other elements affecting its corrosion. Corrosion scales of the low chromium steel had a general two-layer structure: an inner layer containing iron, chromium, oxygen and sulfur, and an outer layer made of porous iron oxide and fly ash particles. Distinct molten phase formation, which is an indication of severe corrosion, was observed for the coal containing only the middle high chlorine, and it initiated in the outer ...

2007-04-15

91

Critical pitting potential of aluminium alloys. Aluminum gokin no koshoku den prime i  

Energy Technology Data Exchange (ETDEWEB)

Pitting corrosion measuring method for almunum alloys sold on the market was studied. By addition of a little quantity of Cu {sup ++} ion, corrosion potential of alminum alloys rapidly approachs to pitting corrosion potential in the solution including chloride. After Cu {sup ++} ion of 5ppm is added in advance into the solution including chrolide to measure the pitting corrosion potential, alminum alloy test pieces are imersed into the solution in the atmospheric air, then the stable corrosion potential is shown after three-minite imersion, and this potential is defined to the pitting corrosion potential. The pitting corrosion potential can be easily measured by this method stated above (copper ion method). The values measured by copper ion method is comparatively agreed with that measured by the existing potentio ...

1990-02-15

92

Corrosion of container materials for disposal of high-level radioactive wastes  

Energy Technology Data Exchange (ETDEWEB)

In the corrosion aspect of container for the deep geological disposal of high-level radioactive waste, disposal concepts and the related container materials, which have been developed by advanced countries, have been reviewed. The disposal circumstances could be divided into the saturated and the unsaturated zones. The candidate materials in the countries, which consider the disposal in the unsaturated zone, are the corrosion resistant materials such as supper alloys and stainless steels, but those in the saturated zone is cupper, one of the corrosion allowable materials. By the results of the pitting corrosion test of sensitized stainless steels (such as 304, 304L, 316 and 316L), pitting potential is decreased with the degree of sensitization and the pitting corrosion resistance of 316L is higher than others. And so, the long-term corrosion ...

1999-01-01

93

Investigation into corrosion fatigue of stainless steels in high concentrated sulfuric acid  

Energy Technology Data Exchange (ETDEWEB)

Four commercial stainless steels (mat. Nos. 1.4539, 1.4586, 1.4571 and 1.4462) were tested in 96% and 90% sulfuric acid of 80/sup 0/C as to their corrosion fatigue strength by subjecting notched round bars to the rotary bending test. At the same time, the efficiency of anodic protection was examined. With all four steels, the alternating bending strength obtained in the air is essentially reduced. The semiaustenitic steel Nr. 1.4462 shows a lower corrosion fatigue strength than the three austenitic steels. Although making the corrosion fatigue strength of steels better calculable, anodic protection proves insufficient to completely prevent notched round bars from corrosion fatigue in concentrated sulfuric acid.

1982-09-01

94

Corrosion resistance characteristic of aluminium bronze containing chromium and zirconium  

International Nuclear Information System (INIS)

There are reported the results of corrosion resistance investigation of aluminium bronzes, containing about 8 and 10% of aluminium and modifying quantities of zirconium. The tests of corrosion resistance were carried out in synthetic seawater, in 3% NaCl aqueous solution and in 10% H_2SO_4 aqueous solution, with reference to industrial bronze BA93 (CuAl9Fe3). The bronzes were tested in an annealed, hardened, tempered state and after plastic hot working. The conclusion is that corrosion resistance of aluminium bronzes, especially against selective corrosion, depends more on material structure, resulted form heat treatment, than on chemical composition. (author). 6 refs, 8 figs, 6 tabs.

95

Understanding the operation and use of high temperature electrochemical corrosion rate probes  

Energy Technology Data Exchange (ETDEWEB)

Electrochemical corrosion rate probes were constructed and tested along with mass loss coupons in a N2/O2/CO2 plus water vapor environment. Temperatures ranged from 450 to 600 C. Corrosion rates for ash-covered mild steel, 304L SS, and 316L SS probes using electrochemical techniques were a function of time, temperature, and process environment. Correlation between electrochemical and mass loss corrosion rates was good.

2004-01-01

96

Effect of chlorides on the corrosion behaviour of mild steel  

International Nuclear Information System (INIS)

In PWR's steam generators, ''denting'' resulted from corrosion of support plate material, carbon steel is an important problem. The role of chlorides in corrosion acceleration of mild steel was studied. Corrosion tests were conducted at temperature from 100"0C to 280"0C in deaerated solutions of NaCl and MgCl_2 which are main content of sea water. 1) Solution of MgCl_2 was more corrosive than that of NaCl. The more increased in concentration of each chloride solution, the more corrosive in MgCl_2 soln. but the less corrosive in NaCl soln. 2) The rate of corrosion in the mixed solution of NaCl and MgCl_2 was governed by the concentration of MgCl_2 soln. The corrosion behaviour in sea water was suggested to be not controlled by NaCl but by MgCl_2. 3) Acidification of MgCl_2 soln. could be evaluated by ...

97

The THIRST chemistry module as a tool to determine optimal steam generator corrosion control strategies  

Energy Technology Data Exchange (ETDEWEB)

As part of a coordinated program, AECL is developing a set of tools to aid with the prediction and management of steam generator performance. Although stress corrosion cracking (of Alloy 800) has not been detected in any operating steam generator, for life management it is necessary to develop mechanistic models to predict the conditions under which stress corrosion cracking is plausible. Therefore, constant extension rate tests were carried out for Alloy 800 under various steam generator crevice chemistry conditions at applied potentials. These tests were designed to evaluate the stress corrosion cracking susceptibility of Alloy 800 under CANDU( steam generator operating conditions. Based on the experimental results, the recommended electrochemical corrosion potential/pH zone for Alloy 800 determined by electrochemical polarization measurements was verified ...

2006-07-01

98

Laboratory Evaluation of Base Materials for Neutralization of the Contaminated Aquifer at the F-Area Seepage Basins  

Energy Technology Data Exchange (ETDEWEB)

Laboratory studies were performed to support field-testing of base injection into the F-Area Seepage Basins groundwater. The general purpose of these experiments is to provide information to guide the test of base injection and to identify potential adverse effects.

2001-09-11

99

Accelerated aging tests for radiation degradation of organic materials  

International Nuclear Information System (INIS)

(Jun 1984). United States Clough, RL Gillen, KT Sandia Nat'l Laboratories

1984-06-03

100

Organometallic Polymer Coatings for Geothermal-Fluid-Sprayed Air-Cooled Condensers: Preprint  

Energy Technology Data Exchange (ETDEWEB)

Researchers are developing polymer-based coating systems to reduce scaling and corrosion of air-cooled condensers that use a geothermal fluid spray for heat transfer augmentation. These coating systems act as barriers to corrosion to protect aluminum fins and steel tubing; they are formulated to resist the strong attachment of scale. Field tests have been done to determine the corrosion and scaling issues related to brine spraying and a promising organometallic polymer has been evaluated in salt spray tests.

2002-08-01

101

Carbon steel corrosion rates and mechanisms in aqueous nickel chloride at 300C  

International Nuclear Information System (INIS)

Rapid corrosion of PWR steam generator carbon steel support structures and consequential denting of steam generator tubes led to considerable investigation of the mechanism of corrosion and for palliatives. The basic mechanism is now fairly well understood. Chloride present in the boiler feedwater from condenser leakage is concentrated in the support plate crevice as a result of the superheat present. This leads to the formation of a low pH acid ferrous chloride environment either through the hydrolysis of a weak base chloride such as MgCl_2 or the combined action of a neutral chloride with an oxidizing agent. Rapid attack of the carbon steel ensues with the Fe_3O_4 corrosion product forming at the metal/oxide interface. This oxide has a volume approximately twice that of the steel consumed and thus eventually fills the crevice between the tube and the support plate. Oxide growth continues leading to compression of the ...

1985-03-01

102

Optimization of INCOLOY alloy 800 mechanical properties for various power plant requirements  

International Nuclear Information System (INIS)

The AMSE Boiler Code development of design stresses and their optimization for alloys 800 and 800H for conventional and nuclear power plants have coincided with many successful trial installations of these grades of alloy 800. These trial installations, along with laboratory tests, have shown that alloy 800H can be used for long times with a retention of good mechanical properties, including ductility. While gamma prime can be formed, it soon loses its detrimental effect on ductility in service. Sensitization of the alloy also occurs but it, too, has a decreasing effect on corrosion resistance with time in service, especially at elevated temperatures. The authors discuss all of these aspects and conclude that alloy 800 perhaps with low carbon control in the annealed (1800 to 1950degF)(982 to 1066degC) condition gives the optimum combination of properties to 1050degF(566degC) and alloy 800H (.05 to .10%C) solution annealed ...

103

ELECTROLYTIC MEMBRANE DIALYSIS FOR TREATING WASTEWATER STREAMS  

Energy Technology Data Exchange (ETDEWEB)

This project will determine whether electrolytic dialysis has promise in the separation of charged particles in an aqueous solution. The ability to selectively move ions from one aqueous solution to another through a semipermeable membrane will be studied as a function of emf, amperage, and particle electrical charge. The ions selected for the study are Cl{sup -} and SO{sub 4}{sup 2-}. These ions are of particular interest because of their electrical conduction properties in aqueous solution resulting with their association with the corrosive action of metals. The studies will be performed with commercial membranes on solutions prepared in the laboratory from reagent salts. pH adjustments will be made with dilute reagent acid and base. Specific objectives of the project include testing a selected membrane currently available for electrolytic dialysis, membrane resistance to extreme pH conditions, the effectiveness of ...

2000-04-01

104

Characterization of the corrosion behavior of the carbon steel liner in Hanford Site single-shell tanks  

Energy Technology Data Exchange (ETDEWEB)

Six safety initiatives have been identified for accelerating the resolution of waste tank safety issues and closure of unreviewed safety questions. Safety Initiative 5 is to reduce safety and environmental risk from tank leaks. Item d of Safety Initiative 5 is to complete corrosion studies of single-shell tanks to determine failure mechanisms and corrosion control options to minimize further degradation by June 1994. This report has been prepared to fulfill Safety Initiative 5, Item d. The corrosion mechanisms that apply to Hanford Site single-shell tanks are stress corrosion cracking, pitting/crevice corrosion, uniform corrosion, hydrogen embrittlement, and microbiologically influenced corrosion. The corrosion data relevant to the single-shell tanks dates back three decades, when results were obtained from in-situ ...

1994-06-01

105

Oxide induced corrosion on the welded stainless steels SS 2352 and 2353; Oxidbetingad korrosion i svetsar hos de rostfria staalen SS 2352 och 2353  

Energy Technology Data Exchange (ETDEWEB)

The pitting corrosion properties have been investigated in welded and unwelded condition by polarization tests in sodium chloride solutions. The two steels were TIG welded without adding welding material and as shielding on the bottom side argon gas containing 2, 26 or 99 ppm oxygen was used. In some tests low breakthrough potentials were received, without discovering any pitting corrosion in the specimen surfaces. The unwelded SS 2352 steel had a critical (lowest) pitting temperature (CPT) of 5 degrees C in the more concentrated solution. For the same steel with weld pitting corrosion was obtained at 5 degrees C, which was the lowest temperature for the tests. Thus the CPT value was lower than 5 degrees C, but by looking at the pitting corrosion potentials the following conclusion could be drawn: Welding with higher oxygen content in the ...

1991-09-16

106

In situ corrosion studies on selected high level waste packaging materials under simulated disposal conditions in rock salt formations  

International Nuclear Information System (INIS)

This paper reports about in-situ corrosion studies on selected materials for long-term resistant high-level waste (HLW) packagings acting as a barrier in a rock salt repository. The materials (Ti 99.8-Pd, Hastelloy C4 and five iron-base materials) were investigated in heated boreholes in the Asse salt mine under simulated HLW disposal conditions prevailing in normal operation of repository and in certain accident scenarios. The experiments under normal operating conditions were performed at temperatures of 120 deg. C to 210 deg. C (vertical temperature profile in the boreholes) without and with gamma irradiation (3#centre dot#10"2 Gy/h, Co-60 source) within the framework of the German/US Brine Migration Test. In these experiments only small amounts of migrated brine inclusions (NaCl-rich) from the rock salt were present as corrosion medium. In the experiments carried out under simulated accident conditions with intrusion of ...

1993-02-01

107

Evaluation of SCC susceptibility of alloy 800 under CANDU SG secondary-side conditions  

Energy Technology Data Exchange (ETDEWEB)

As part of a coordinated program, AECL is developing a set of tools to aid with the prediction and management of steam generator performance. Although stress corrosion cracking (of Alloy 800) has not been detected in any operating steam generator, for life management it is necessary to develop mechanistic models to predict the conditions under which stress corrosion cracking is plausible. Therefore, constant extension rate tests were carried out for Alloy 800 under various steam generator crevice chemistry conditions at applied potentials. These tests were designed to evaluate the stress corrosion cracking susceptibility of Alloy 800 under CANDU( steam generator operating conditions. Based on the experimental results, the recommended electrochemical corrosion potential/pH zone for Alloy 800 determined by electrochemical polarization measurements was verified ...

2006-07-01

108

Evaluation of SCC susceptibility of alloy 800 under CANDU SG secondary-side conditions  

International Nuclear Information System (INIS)

As part of a coordinated program, AECL is developing a set of tools to aid with the prediction and management of steam generator performance. Although stress corrosion cracking (of Alloy 800) has not been detected in any operating steam generator, for life management it is necessary to develop mechanistic models to predict the conditions under which stress corrosion cracking is plausible. Therefore, constant extension rate tests were carried out for Alloy 800 under various steam generator crevice chemistry conditions at applied potentials. These tests were designed to evaluate the stress corrosion cracking susceptibility of Alloy 800 under CANDU( steam generator operating conditions. Based on the experimental results, the recommended electrochemical corrosion potential/pH zone for Alloy 800 determined by electrochemical polarization measurements was verified ...

2006-11-26

109

Development of engineered structural barriers for nuclear-waste packages  

Energy Technology Data Exchange (ETDEWEB)

The development of structural barriers for nuclear waste packages involves selection of candidate materials, their screening by mechanical and corrosion testing, rigorous accelerated testing, and evaluation and comparison with other package elements. This document presents results from work conducted on titanium and ferrous alloys.

1981-09-01

110

Surface modification on magnesium alloys by coating with magnesium fluorides  

Energy Technology Data Exchange (ETDEWEB)

A new technique has been developed for improving corrosion resistance on magnesium alloys. Specimens of AZ31 magnesium alloy were dipped into molten salt of NaBF{sub 4} at 723 K for various times, and then cooled, rinsed with water, and dried in air. Corrosion resistance in the surface treated specimens was evaluated by salt immersion test using 1% NaCl solution as a time for occurring filiform corrosion. On an un-treated AZ31 alloy, the time for starting the filiform corrosion was about 1.2 ks, while on the surface treated specimen, the time was prolonged into about 1300 ks. Moreover, the surface treated specimen showed corrosion resistance in low pH solutions, such as 1% HNO{sub 3} and HCl solutions. (orig.)

2005-07-01

111

Sialon sintering product excellent in liquid sodium corrosion resistance  

International Nuclear Information System (INIS)

A sialon sintering product of the present invention comprises #beta#'-sialon grains and less than 2vol% of a grain boundary phase, and a relative density of the sintering product is greater than 98%. It exhibits a high temperature strength of greater than 500Mpa at 650degC and shows such high corrosion resistances that the reduction of the volume due to corrosion is less than 0.5mg/cm"2 in a liquid sodium immersion test, and the corrosion of the grain boundary is not observed. Accordingly, there can be provided a sialon sintering product excellent in corrosion resistance in a liquid sodium circumstance while keeping the high temperature strength as an excellent characteristic of the sialon sintering product. (T.M.).

1995-04-19

112

Ceramic linings beat coal plant's abrasion/corrosion problems  

Energy Technology Data Exchange (ETDEWEB)

A combination of erosion and corrosion at the Victoria Junction coal preparation plant in Sydney, Nova Scotia was causing serious problems. Schedule 80 mild steel pipes were starting to fail as well as some quarter-inch steel plates in the lauders and chutes. Some corrosion tests were carried out and the high chloride level in the process water was felt to be the single most important contribution to the corrosion problem. Cast basalt was selected as a solution to the pipe wear problem. Three different types of abrasion/corrosion-resistant tiling - basalt tiles, kalceram tiles and ceramic tiles were well suited to the chloride conditions at this plant.

1985-07-01

113

Materials choices for the advanced LWR steam generators  

International Nuclear Information System (INIS)

Current light water reactor (LWR) steam generators have been affected by a variety of corrosion and mechanical damage degradation mechanisms. Included are wear caused by tube vibration, intergranular corrosion, pitting, and thinning or wastage of the steam generator tubing and accelerated corrosion of carbon steel supports (denting). The Electric Power Research Institute (EPRI) and the Steam Generator Owners Groups (I, II) have sponsored laboratory and field studies to provide ameliorative actions for the majority of the damage forms experienced to date. Some of the current corrosion mechanisms are aggravated or caused by unique materials choices or materials interactions. New materials have been proposed and at least partially qualified for use in replacement model steam generators, including an advanced LWR design. In so far as possible, the materials choices for the advanced LWR ...

1987-11-15

114

Influence of thin oxide films on pitting corrosion of CrNi steels. Beeintraechtigung der Lochkorrosionsbestaendigkeit von CrNi-Staehlen durch duenne Oxidschichten  

Energy Technology Data Exchange (ETDEWEB)

Chloride-induced pitting corrosion of stainless steel (Materials No. 1.4301 and 1.4571) was investigated with the aid of chronopotentiostatic tests. Oxide films upon the surface (temper colours), addition of inhibitors (sulphate and nitrate) and temperature were the testing variables. Two different critical pitting potentials have been found, which give information on the potential ranges for stable passivity, latent and stable pitting corrosion. The results only indicate a small effect of Mo content of the material and test temperature. The inhibitors (sulphate and nitrate) have a marked effect. Specimens with a clean surface produced by pickling are markedly more resistant against pitting corrosion than specimens with a yellow temper colour, whereas the difference in corrosion resistance between yellow and blue films is relatively small. ...

1993-09-01

115

Intergranular corrosion in Alloy 800: intercomparison between the Strauss test, the EPR method, and magnetic permeability measurements  

Energy Technology Data Exchange (ETDEWEB)

The susceptibility to intergranular corrosion of different heats of Alloy 800 was evaluated by three different methods: the ASTM A 262 Practice E (or modified Strauss test), the Electrochemical Potentiokinetic Reactivation method, and by magnetic-susceptibility measurements. Reasonably good agreement was found between the sensitization areas as defined by the three methods in the TTS diagrams. In some cases the area defined by the Strauss test was slightly smaller than that determined by the other two tests. The differences might be explained by the fact that the methods present different sensitivities to the chromium concentration at the grain boundaries. 27 references, 11 figures, 3 tables.

1982-01-01

116

Results on incoloy 800 and allied steam generator materials in Florida field corrosion tests  

International Nuclear Information System (INIS)

Appraisals of the isothermal general corrosion of Incoloy 800 in steam at 595 and 650 deg.C indicated good long-term resistance (<7 mg/cm"2 weight gained in 20 years) whether surfaces were ground or electropolished. Electropolished surfaces corroded much faster than ground surfaces in earlier stages, (39 and 15 times as fast in 3000 hr at 595 and 650 deg.C, respectively), but the corrosion rate decreased with time and gave comparable estimates over the long term for both surface preparations. Both nonwelded and welded Incoloy 800 were definately susceptible in chloride stress-corrosion cracking tests of U-bend specimens in a cyclic, wet-dry steam environment. However, C-configuration specimens of Incoloy 800, which were less severly strained, did not crack in this environment. (author).

117

Evaluation, testing and database generation of pitting corrosion characteristics of domestic steam generator tubing material  

Energy Technology Data Exchange (ETDEWEB)

Accumulation of Chloride and Cupric ions under the sludge on the steam generator tubing surface in the area between tube sheet and the first tube support is known to be the main reason for the pitting corrosion. In addition to those ions, oxygen, pH, temperature, heat treatment history, contests of minor elements such as C, S or Ti in the alloy are also influencing the material's the pitting corrosion resistance. a series of autoclave pitting test was conducted to evaluate the pitting corrosion characteristics of the domestically produced alloy 690 tubing material and compare with that of INCO manufactured material. 16 refs., 44 figs., 5 tabs. (Author)

1998-04-01

118

A new technique for surface modification in magnesium alloys by applying magnesium oxide coating  

Energy Technology Data Exchange (ETDEWEB)

A new technique was proposed in order to improve poor corrosion resistance in magnesium. That is, magnesium hydroxide film was formed on the surface of 3 N-Mg by artificial corrosion in 1% MgCl{sub 2} solution for 3.6 ks, which followed by oxidation at 673 K for 3.6 ks in air. Corrosion resistance was evaluated by salt immersion tests in 1% NaCl solution under in situ laser microscopic observations. Bubble evolution, which occurred immediately at the beginning of the immersion test in the case of non-treated specimen, was suppressed by the process. And also, formation of filiform corrosion was suppressed for about 3.6 ks, which occurred at 180 s in the non-treated specimen. (orig.)

2003-07-01

119

Statistical characterization of pitting corrosion process and life prediction  

International Nuclear Information System (INIS)

In order to prevent corrosion failures of machines and structures, it is desirable to know in advance when the corrosion damage will take place, and appropriate measures are needed to mitigate the damage. The corrosion predictions are needed both at development as well as operational stage of machines and structures. There are several forms of corrosion process through which varying degrees of damage can occur. Under certain conditions these corrosion processes at alone and in other set of conditions, several of these processes may occur simultaneously. For a certain type of machine elements and structures, such as gears, bearing, tubes, pipelines, containers, storage tanks etc., are particularly prone to pitting corrosion which is an insidious form of corrosion. The corrosion predictions are usually based on ...

120

Recycle of iodine-loaded silver mordenite by hydrogen reduction  

Science.gov (United States)

In 1977 and 1978, workers at Idaho National Engineering Laboratory (INEL) developed and tested a process for the regeneration and reuse of silver mordenite, AgZ, used to trap iodine from the dissolver off-gas stream of a nuclear fuel reprocessing plant. We were requested by the Airborne Waste Management Program Office of the Department of Energy to perform a confirmatory recycle study using repeated loadings at about 150/sup 0/C with elemental iodine, each followed by a drying step at 300/sup 0/C, then by iodine removal using elemental hydrogen at 500/sup 0/C. The results of our study show that AgZ can be recycled. There was considerable difficulty in stripping the iodine at 500/sup 0/C.; however, this step went reasonably well at 550/sup 0/C or slightly higher, with no apparent loss in the iodine-loading capacity of the AgZ. Large releases of elemental iodine occurred during the drying stage and the early part of the stripping stage. Lead ...

1982-11-01

121

Prevention of pitting corrosion on copper tubes in central hot water supply systems by UV photochemical decomposition of residual chlorine  

Energy Technology Data Exchange (ETDEWEB)

After confirming that residual chlorine in tap water, which is regarded as one of the major cause of pitting corrosion, can be decomposed/removed by the irradiation of UV light, effect of dechlorinated water obtained based on this principle on the prevention of pitting corrosion, generation and growth, of the copper tubing was investigated by a corrosion test simulated the actual system in high buildings. (1) Low pressure type mercury lamp easily decompose/remove the residual chlorine. (2) If the dechlorinated water is supplied from the initial stage of copper tube usage, potential of the copper tube remains at the level of 100 mV/SCE and the generation of pitting corrosion is not observed. (3) Even when pitting corrosion is already found, switching to dechlorinated water in the midway reduces the potential of the copper tube down to 50 - 70 mV level, at the ...

1988-03-25

122

Limit of pitting corrosion at high-alloyed special steels and NiCrMo alloys in chloride solution; Die Lochkorrosionsbegrenzung bei hochlegierten Sonderedelstaehlen und NiCrMo-Legierungen in Chloridloesung - Einflussfaktoren und Ausmass  

Energy Technology Data Exchange (ETDEWEB)

The phenomenon of the limit of pitting corrosion in direction to positive potentials is studied by potentiokinetic polarization after a jump in the transpassive range and by potentiostatic tests at technical wrought materials and at model alloys of the systems NiCrMo and NiMo in CaCl{sub 2} solution in the concentration range 1 to 9 mol/l chloride at pH-values of 1 to 9 at temperatures of 30 to 110 C. Surface-analytical investigations gives in connection with knowledges from anodic polarization studies directions to the mechanism of the limit of pitting corrosion. Ranges of the limit of pitting corrosion are obtained at materials with a Mo content above 6.5% and contents of chloride of the media above 2 mol/l chloride. Increasing temperatures, increasing contents of chloride and sulfate shift the potential of the limit of pitting corrosion being always above 0.2 V (SCE) at ...

2001-08-01

123

Evaluation of new corrosion-resistant superheater tubing in high-efficiency waste-to-energy plants  

Energy Technology Data Exchange (ETDEWEB)

Field corrosion tests were conducted on eight single tube materials and two welded overlay materials in three typical Japanese waste incineration plants in an effort to develop new corrosion-resistant superheater tubes capable of functioning efficiently under temperature and pressure conditions of 500 C and 100 kgf/cm{sup 2}-g in high-efficiency waste-to-energy (WTE) plants. Austenitic alloys containing higher concentrations of chromium, nickel, and molybdenum [Cr + Ni + Mo] showed excellent corrosion-resistant properties, and the new alloys JHN24 and HR30M showed good corrosion resistance. Different corrosion rates found in each of the three plants were explained by differences in operating conditions, such as gas temperature, concentration of molten salts resulting from chlorine (Cl) content of deposits, heavy metal (zinc oxide [ZnO] + lead oxide [PbO]) ...

1998-07-01

124

Pitting corrosion resistance of high alloy OCTG in ferric chloride solution  

International Nuclear Information System (INIS)

The effects of alloying elements and precipitated phases on the corrosion rate of high alloy OCTG in the ferric chloride solution have been evaluated. The corrosion rate of Fe-Cr-Ni-Mo alloys without precipitated phases, e.g. carbides and sigma phase, can be estimated from the composition using the following equation: log(C.R.)=-0.144xPRE-7690/(273+T)+28.6 where C.R. is the corrosion rate in g/m/sup 2//hr; PRE is Cr+3Mo+16N in percent and T is the test temperature in "0C. The activation energies of the ferric chloride test are almost the same regardless of PRE or Ni content when no detrimental phase precipitates. When carbides or the sigma phase precipitate, the corrosion rate is higher and the activation energy is lowered. This suggests that secondary phases give preferential sites for initiation of pitting corrosion.

125

Influence of C, N and Nb contents on intergranular corrosion, stress corrosion cracking and mechanical strength of alloy 600  

International Nuclear Information System (INIS)

Dependence of C, N and Nb contents on intergranular corrosion (IGC), strews corrosion cracking (SCC) and mechanical strength of alloy 600 were examined. To evaluate the corrosion resistance of heat affected zone (HAZ), post weld heat treated specimens were used. To evaluate I G C and S C C susceptibility, Ferric Sulfate-Sulfuric Acid Test and High Temperature Water Test were used. Nb is effective as a stabilizer of C. Consequently to prevent corrosion attack on H A Z in high temperature water Nb should be added more than 100 ( % C - 0.005)% and to maintain mechanical strength, Nb should be added more than 3 + 75( %C + %N)%. Modified alloy 600 satisfying above condition was manufactured commercially and its various properties including weldability were confirmed to be excellent.

1985-12-01

126

Is OD peening of Alloy 800 SG tubes desirable?  

Energy Technology Data Exchange (ETDEWEB)

The shot peening of the outer surface of Alloy 800 is proposed by the steam generator supplier in order to increase the stress corrosion cracking resistance of the tubes. The benefits and drawbacks of such a treatment are evaluated, focusing on the main concern i.e. a possible enhanced tendency of stress corrosion cracking at the transition of the expanded tube-to-tubesheet joint. Stress corrosion tests as well as residual stresses measurements demonstrate no significant difference between peened and unpeened tubes at that location. The other concerns such as stability of the compressive stresses, increased risk of pitting or intergranular attack and pollution of the secondary circuit by fragmented beads appear the as minor concerns.

1992-12-31

127

Development of ALLOY 800 for PWR/SG tubings resistant to IGSCC and general corrosion  

Energy Technology Data Exchange (ETDEWEB)

Resistance of ALLOY 800 as a PWR/SG tubings to IGC/IGSCC and Ni, Co release into high temperature water was evaluated as compared with ALLOYs 600 and 690. The study to improve the resistance to IGSCC and general corrosion was also made. From the results, ALLOY 800 was evaluated to be the most reliable among the high Ni alloys tested. In addition, the alloy would obtain further reliability in IGSCC and general corrosion resistance by the combined addition of Ti and Nb, and the prior oxidation treatments, respectively. (author).

1989-07-01

128

Corrosion resistance of #gamma#-solid solution and hardening #gamma#'-phase of nickel alloys in sodium sulfate and chloride melts  

International Nuclear Information System (INIS)

Corrosion testings of model alloys, corresponding by chemical composition to simple and complex-alloyed #gamma#- and #gamma#'-phases of nickel heat-resistant alloys are conducted in sodium sulfate and chloride melts. It is ascertained that heat resistant nickel alloys containing over 50 % of hardening #gamma#'-phase, are subject to disastrous sulfide corrosion (SC). Resistance against SC alloys containing below 50 % of #gamma#'-phase is determined by the resistance of #gamma#-solid solution. 10 refs., 3 figs., 2 tabs.

129

Kinetics of salt concentration in heated crevices  

International Nuclear Information System (INIS)

In PWR steam-generators, the crevice between tube and tube-support plate tends to fill with porous deposits during operation and acts as a concentration site for chemicals in the boiler water, which may lead to corrosion of the tube and tube-support-plate. The rate of concentration, the magnitude of the concentration factor and the rate of release of solute when conditions change are important parameters for devising strategies to minimize corrosion. Values of these parameters for salt concentration have therefore been measured in a laboratory simulation of the crevice and are used to formulate a model of the concentrating process.

1985-03-01

130

Corrosion studies at the Wilsonville, Alabama, coal liquefaction facility during 1983  

Science.gov (United States)

During 1983, Oak Ridge National Laboratory continued a study of materials performance at the Wilsonville, Alabama, Advanced Coal Liquefaction Research and Development Facility. Materials performance was evaluated by exposure and analysis of corrosion coupons and U-bend specimens, chemical analysis of related process streams, and ultrasonic determination of the thickness of walls of various components. The results of these studies are useful to current plant operators and to designers of future large-scale plants. 18 references, 4 figures, 12 tables.

1984-10-01

131

Stress corrosion cracking of Alloy 600 using the constant strain rate test  

International Nuclear Information System (INIS)

Nuclear grade production tubing of Alloy 600 was evaluated for stress corrosion cracking (SCC) susceptibility in high purity water at 365, 345, 325, and 290 C. Reverse tube U-bend specimens provided crack initiation data and constant extension rate tests were employed to determine the crack velocities experienced in th crack propagation stage. Initial results indicate that a linear extrapolation of data received from high temperature tests can be used to predict the service life of steam generator tubing that has been plastically deformed or is continually deforming by ''denting.''.

132

Enhanced corrosion resistance properties of radiofrequency cold plasma nitrided carbon steel: Gravimetric and electrochemical results  

Energy Technology Data Exchange (ETDEWEB)

Cold plasma nitriding treatment was performed to improve the corrosion resistance of C38 carbon steel. Nitriding process was conducted using a radiofrequency nitrogen plasma discharge for different times of treatment on non-heated substrates. The modification of the corrosion resistance characteristic of the C38 steel due to the treatment in acid medium (1 M HCl) were investigated by gravimetric and electrochemical tests such as potentiodynamic polarisation curves and electrochemical impedance spectroscopy (EIS). It was shown that the plasma nitriding treatment improves the corrosion resistance. Indeed, in the gravimetric tests, nitrided samples showed lower weight loss and lower corrosion rate in comparison to untreated one. In the Tafel polarisation tests, the nitrided samples showed greatly reduced corrosion current ...

2009-03-01

133

Seismic Testing of Reactor Components.  

Science.gov (United States)

This report is the final report on the seismic testing of reactor components conducted since 1977 with opening of the vibration laboratory at KAERI. In 1979, forced vibration testing of Wolsung-1 steam generator model using sine dwell and white nosie rand...

1980-01-01

134

Status of the Lawrence Berkeley Laboratory and Lawrence Livermore National Laboratory free electron laser (FEL)  

Energy Technology Data Exchange (ETDEWEB)

A description of the FEL experiment underway at the 10 kA, 5 MeV Experimental Test Accelerator (ETA) is described. The facility has been designed to investigate the high-gain operation of an FEL.

1983-09-19

135

Interaction effects of ethanol and pyrazole in laboratory rodents  

UK PubMed Central (United Kingdom)

1. Interactions of pyrazole and ethanol were studied in three laboratory test procedures. They included sleeping time in mice, rotor rod balance in rats and lever pressing behaviour of rats. 2....Full Text Available

1971-09-01

136

Corrosion performance of low- and high-alloy as well as coated steels in undisturbed long-time exposure to natural sea water. [St 37-2, 10 CrMo 9 10, X2 CrNiMo 18 14 3; X2 CrNiMoN 17 13 5, X2 CrNiMoN 22 5 3; X1 CrNiMoNb 28 4 2]. Korrosionsverhalten von niedrig- und hochlegiertem sowie beschichtetem Stahl bei ungestoerter Langzeitauslagerung in natuerlichem Meerwasser  

Energy Technology Data Exchange (ETDEWEB)

The procedure for field corrosion tests in sea water is decribed in DIN 50 917, Part II. Distinction is made thereby between long-term undisturbed test specimens, which remain at the exposure site up to the time of sampling, and disturbed test specimens, which are cleaned at certain time intervals for intermediate examination and subsequently exposed again. The comparability of results obtained with the two different types of test was to be investigated at the Helgoland test installation. At an exposure period of up to four years, undisturbed specimens of unalloyed and low-alloy steel grades feature considerably lower corrosion losses than disturbed specimens. At a longer exposure period of up to seven years, the corrosion rate can increase substantially again with the exposure time. This can be attributed to sulphate ...

1990-09-14

137

Poster 20. Analysis of chemical environment conditions in boiling zones  

International Nuclear Information System (INIS)

Boiling phenomenon is responsible for impurities concentration in the liquid phase and then can involve chemically aggressive conditions. This paper presents the methodology developed by NOVATOME to know the water quality conditions in the boiling zone and under deposits, in order to improve corrosion tests and materials reliability and safety. Calculations show that concentration of chloride and sodium hydroxide for example can reach significant levels which may lead to corrosion risks. (author).

138

Oceans 82 conference record: Industry, government, education. partners in progress  

Energy Technology Data Exchange (ETDEWEB)

Separate abstracts were prepared for 20 papers in this conference report and includes all papers in the ''engineering'' section (program E). Ocean thermal energy conversion (OTEC), moorings, cables, corrosion protection, corrosion testing, coatings, offshore platforms, pipelines, OTEC models and pilot plants, and energy transfer are topics discussed.

1982-01-01

139

Research on corrosion resistance of steam generator tube  

International Nuclear Information System (INIS)

In order to improve the reliability of PWR steam generators, we have performed research to improve the tubing material and tube-support-plate configuration, based on our wide operating experience, and have developed and verified Alloy TT690 as the optimum tubing material and the BEC (Broached Egg Crate) type tube-support design. In the research, we have studied the metallurgical mechanism of the alloy to improve its corrosion resistance, evaluated corrosion susceptible region quantitatively, estimated the actual environment in a steam generator and confirmed the reliability by a model boiler test over a long period. It has been verified that the steam generator with the latest design has higher reliability with respect to the corrosion resistance of tubes. (author).

140

New monitoring system for microbiological control effectiveness on pitting corrosion of carbon steel  

Energy Technology Data Exchange (ETDEWEB)

A new on-line monitoring system has been developed for pitting corrosion monitoring of carbon steel tubes in cooling water systems. This monitoring system was found to be quite sensitive to the microbiological activity relating to pitting corrosion on a real-time basis. The value of galvanic current indicates the performance level of pitting corrosion inhibition even in biocide application. In addition, the changes in the galvanic current provide indicative information about the effectiveness in microbiological control program, even when the pressure drop measurement indicates no biofilm formation. It can be also useful in detecting a microbiological control upset. In this paper, an introduction of the new monitoring system as a microbiological control effectiveness monitor and the field test results are discussed.

1997-12-01

141

IGC/IGSCC and general corrosion behavior of alloy 800 as a PWR S/G tube material  

Energy Technology Data Exchange (ETDEWEB)

Resistance of Alloy 800 as a PWR S/G tube material to IGC/IGSCC and Ni, Co release into water was evaluated as compared with Alloys 600 and 690. The study to improve the resistance to IGSCC and general corrosion was also made, including the effects of shot-peening on the distribution of the residual stress of the U-bent tubes and the susceptibility to SCC, the stabilizing elements on IGC/IGSCC, and prior oxidation on general corrosion. From the results, shot-peened Alloy 800 was estimated to be the most reliable S/G tube material among the high nickel alloys tested. In addition, the Alloy 800 tube would obtain further reliability in IGSCC and general corrosion resistance by the combined addition of Ti, and Nb, and the prior oxidation of the inner tube surface, respectively.

1987-01-01

142

IGC/IGSCC and general corrosion behavior of alloy 800 as a PWR S/G tube material  

International Nuclear Information System (INIS)

Resistance of Alloy 800 as a PWR S/G tube material to IGC/IGSCC and Ni, Co release into water was evaluated as compared with Alloys 600 and 690. The study to improve the resistance to IGSCC and general corrosion was also made, including the effects of shot-peening on the distribution of the residual stress of the U-bent tubes and the susceptibility to SCC, the stabilizing elements on IGC/IGSCC, and prior oxidation on general corrosion. From the results, shot-peened Alloy 800 was estimated to be the most reliable S/G tube material among the high nickel alloys tested. In addition, the Alloy 800 tube would obtain further reliability in IGSCC and general corrosion resistance by the combined addition of Ti, and Nb, and the prior oxidation of the inner tube surface, respectively.

1987-03-09

143

Initiation process of type 1 pitting corrosion on copper water-tubes; Reisui yo dokan ni okeru 1 gata koshoku no hassei  

Energy Technology Data Exchange (ETDEWEB)

Copper tubes have been widely used for water supply and heat exchangers. In such systems copper tubes often suffer from type 1 pitting-corrosion. A mechanism, of the type I pitting-corrosion on copper tubing has been presented, but a initiation mechanism of the pitting corrosion is still unknown. In this paper we aimed to clarify the initiation mechanism of the pitting corrosion. Copper-tube specimens were immersed in a circulating solution. The solution had been used for heat exchangers at a Japanese factory where the water leakage occurred by the pitting corrosion on copper tubes. The solution contained tiny precipitates resulted from corrosion of galvanized steel pipe. During the immersion test changes in the surface state of a copper tube was analyzed by in situ RAMAN (in situ Raman Spectroscopy), SEM (Scanning Electron Microscope), EPMA ...

1999-07-15

144

The effect of annealing parameter on corrosion resistance of Zircaloy-2  

International Nuclear Information System (INIS)

The effects of equal #SIGMA#Ai for different combinations of the annealing temperature and annealing time on corrosion resistance and evolution of precipitates of Zircaloy-2 were investigated. Nodular corrosion resistance in the out-of-pile corrosion test was degraded with increasing #SIGMA#Ai only when it was increased by extending the annealing time at 894 K but did not depend on #SIGMA#Ai which was increased by raising the annealing temperature for a constant annealing time of 2.5 h. Extensive observation and micro-analysis of precipitates by analytical electron microscope (AEM) suggested the cause of degradation of nodular corrosion resistance to be the remarkable increase in volume fraction of Si-containing precipitates such as Zr_3Si and Zr_2Si, which were observed more frequently in large #SIGMA#Ai only when it was increased by extending the annealing time at 894 K. On the ...

145

Influence of sigma-phase formation on the localized corrosion behavior of a duplex stainless steel  

International Nuclear Information System (INIS)

Because of their austenitic-ferritic microstructures, duplex stainless steels offer a good combination of mechanical and corrosion resistance properties. However, heat treatments can lower the mechanical strength of these stainless steels as well as render them susceptible to intergranular corrosion (IGC) and pitting corrosion. In this study, a low-carbon (0.02%) duplex stainless steel is subjected to various heat treatments at 450 to 950 C for 30 min to 10 h. The heat-treated samples than undergo ASTM IGC and pitting corrosion tests, and the results are correlated with the microstructures obtained after each heat treatment. In the absence of Cr_2_3C_6 precipitation, #sigma#-phase precipitates render this duplex stainless steel susceptible to IGC and pitting corrosion. Even submicroscopic #sigma#-phase precipitates are deleterious for IGC resistance. ...

1996-01-01

146

Influence of sea water on the fatigue strength and notch sensitivity of a plasma nitrided B-Mn steel  

Energy Technology Data Exchange (ETDEWEB)

Notched and smooth cylindrical plasma nitrided (PN) and quench and tempered (Q and T) steel specimens made of a B-Mn SS2131 ({approx}AISI 15B21H) steel have been exposed to constant amplitude plane reversed bending corrosion fatigue tests (R = -1) at 47 Hz in sea water. S - N curves show that sea water suppresses the fatigue limit and reduces fatigue strength (especially at long lives) of smooth and notched Q and T and PN specimens. Plasma nitriding improves the corrosion fatigue resistance of Q and T specimens; this is associated with the good corrosion resistance of {epsilon} and {gamma}`-phases, the enhancement of corrosion and fatigue by compressive residual stresses, and the consumption of H{sup +} ions during reduction of nitrogen. This improvement is more significant for smooth specimens and for long lives. Notch sensitivity of Q and T and PN specimens decreases with fatigue ...

1998-06-01

147

Effects of Cr content and the addition of Cr_2O_7"2"- ion on corrosion resistance of stainless steel in nitric acid solutions  

International Nuclear Information System (INIS)

A nitric acid solution containing Cr_2O_7"2"- ion is used for a corrosion test which simulates the condition in a nuclear fuel reprocessing plant. As the effect of Cr content on the corrosion resistance of stainless steel is not yet fully understood in that solution, the effects of Cr content in an alloy and that of Cr_2O_7"2"- ion in nitric acid on the corrosion rate were studied by using electro-chemical measurements. The increase of Cr content reduced the general corrosion rate in nitric acid solution without Cr_2O_7"2"- ion, however it increased that in nitric acid solution containing Cr_2O_7"2"- ion. It is considered that the reversal of the Cr content dependency is due to a rise of the corrosion potential caused by addition of Cr_2O_7"2"- ion to the potential region where a high Cr alloy shows higher anodic dissolution rate than a low Cr content alloy. ...

148

Effect of micro segregation on pitting corrosion of SCS 14 austenitic stainless steel castings in sea water environments; SCS 14 osutenaitokei sutenresuchuko no kaisuichu deno koshoku kyodo ni oyobosu mikuro henseki no eikyo  

Energy Technology Data Exchange (ETDEWEB)

Austenitic stainless steel castings, such as SCS 13, SCS 14, which consists of {delta}/{gamma} duplex phase, are extensively used as structural material in seawater environments. It is known that SCS 14 involving 2wt% Mo is more resistant to pitting corrosion than SCS 13. In this paper, effects of Mo on the pitting corrosion are discussed in terms of microstructure of the material. The corrosion behavior of the materials with different {delta} ferrite contents and cleanlinesses have been evaluated by seawater exposure testing, electrochemical polarization, and TEM-EDX analysis. The results indicate that pits mainly nucleate at nonmetallic inclusions such as MnS and {delta}/{gamma} boundaries, and materials containing {delta} ferrite above 7vol% have high pitting corrosion resistance. The nucleation at {delta}/{gamma} boundaries is assumed to be due to the segregation of P. It is ...

1999-06-15

149

Corrosion of fluidized-bed boiler materials in synthetic flue gas  

Energy Technology Data Exchange (ETDEWEB)

Candidate materials for components of a fluidized-bed waste heat recovery system (FBWHRS) include plain carbon steel, types 405 and 316 stainless steel, and alloy 800. These materials were exposed to synthetic flue gas at anticipated FBWHRS temperatures and higher for 3000 h to determine corrosion rates. The synthetic flue gas was a combustion atmosphere to which Cl/sub 2/ and HCl were added. The projected annual corrosion rate for plain carbon steel is about 0.08 mm/year (0.003 in./year) at 250 to 290/sup 0/C, but it would exceed 0.5 mm/year (0.02 in./year) at 560/sup 0/C. The projected annual corrosion rates of the other materials were less than 0.25 mm/year (0.01 in./year) at the maximum test temperatures of 560, 660, and 665/sup 0/C for type 405, type 316, and alloy 800, respectively. These results indicate that corrosion of candidate FBWHRS materials will not be significant at ...

1983-11-01

150

Corrosion in drilling and well stimulation  

Energy Technology Data Exchange (ETDEWEB)

Corrosion in drilling and well stimulation is described in relation to acid corrosion inhibition, acid inhibitors, acetylenic inhibitors, synergistic blends, metallurgy, wellbore tubulars, coiled tubing, and high alloy tubular materials. Acidizing is a procedure for stimulating oil and gas wells. Factors that have an important influence on the reaction rate and the way in which acid reacts with rock include temperature, acid concentration, acid volume, injection velocity, acid viscosity, and fluid loss properties of the formation. The cost of drill pipe failures are $1 per fot of hole drilled, which is a significant fraction of the drilling cost. Steps in a test procedure are listed, as well as factors which determine the extent of acid corrosion in a given situation including acid type and strength, metal type, temperature, contact time; pressure, and volume/surface area ratio. Underbalanced drilling ...

1999-07-01

151

Behavior at under-film corrosion tips of Zn-Fe alloy coated steel sheets. Zn-Fe gokin mekki koban no tomakushita fushoku ni okeru fushoku sentanbu no kyodo  

Energy Technology Data Exchange (ETDEWEB)

From a macroscopic point of view, corrosion of Zn alloy coated steel sheet occurs by the coating preceding corrosion mechanism; microscopically, however, the coated layer corrosion velocity in the tip of corrosion is different. In order to find the main factors of under-film corrosion of Zn and Zn-Fe alloy coatings in the salt water spray atmospheric exposure test, the correlation between point inflation-exfoliation width and chlorine penetration behavior, point adhesion, and the difference in chlorine penetration behavior due to alloy coating components were investigated. Consequently, the following results were obtained: 1. The better correlation was observed between chlorine penetration distance and point inflation-point exfoliation width. 2. The durability of coating against chlorine penetration improved by increase in point adhesion and Zn content in the ...

1990-09-01

152

A comparison of the corrosion behaviour and hardness of steel samples (100Cr6) coated with titanium nitride and chromium nitride by different institutions using different deposition techniques  

Energy Technology Data Exchange (ETDEWEB)

Deposition of hard coatings may influence the mechanical properties of the bulk material and its corrosion resistance. In this work we study the hardness of the coated and the back side of 100Cr6 steel plates. Electrochemical corrosion tests were performed in O{sub 2}-saturated acetate buffer of pH 5.6 at 25degC. Chromium nitride and titanium nitride coatings prepared by different physical vapour deposition processes, such as arc, thermionic arc evaporation, magnetron sputtering and ion-beam-assisted deposition (IBAD) were compared. The results show that, for sufficient corrosion protection, chromium nitride layers have to be thicker than 500 nm. An increased nitrogen partial pressure in the evaporation chamber of the IBAD process improves the corrosion resistance significantly. The hardness of the substrates was reduced in the case of thermoionic arc evaporation only, indicating a ...

1991-07-07

153

Investigation of corrosion experienced in a spray calciner/ceramic melter vitrification system  

Energy Technology Data Exchange (ETDEWEB)

After periodic testing of a large-scale spray calciner/ceramic melter vitrification system over a 2-yr period, sufficient corrosion was noted on various parts of the vitrification system to warrant its disassembly and inspection. A majority of the 316 SS sintered metal filters on the spray calciner were damaged by chemical corrosion and/or high temperature oxidation. Inconel-601 portions of the melter lid were attacked by chlorides and sulfates which volatilized from the molten glass. The refractory blocks, making up the walls of the melter, were attacked by the waste glass. This attack was occurring when operating temperatures were >1200/sup 0/C. The melter floor was protected by a sludge layer and showed no corrosion. Corrosion to the Inconel-690 electrodes was minimal, and no corrosion was noted in the offgas treatment system downstream of the sintered ...

1980-08-01

154

Effect of lead and silicon on localized corrosion of Alloy 800 in steam generator crevice environments  

Energy Technology Data Exchange (ETDEWEB)

The Alloy 800 tubes used in CANDU 6 steam generators have not experienced significant corrosion damage to date, which may be attributed to successful water chemistry control strategies. However, it is known that Alloy 800, like other steam generator (SG) tubing materials, is not immune to corrosion, especially pitting, under some plausible but off-specification operating scenarios. Electrochemical measurements provide information on corrosion susceptibility and rate, which are known to be a function of water chemistry. Using laboratory data in combination with chemistry monitoring and diagnostic software it is possible to assess the impact of plant operating conditions on SG tube corrosion for plant life management (PLIM). In this context, this paper discusses the results of electrochemical measurements made to elucidate the corrosion behaviour of Alloy 800 SG ...

2001-09-01

155

Evaluation of new corrosion resistant superheater tubings in high efficiency waste-to-energy plants  

Energy Technology Data Exchange (ETDEWEB)

In order to develop new corrosion resistant superheater tubes capable of functioning efficiency under temperature and pressure conditions of 500 C and 100 ata used in high efficient waste-to-energy (WTE) plants, field corrosion tests were conducted on eight single tube materials and two welded overlay materials at metal temperatures of 450 C and 550 C for 700 and 3,000 hours, respectively, in three typical japanese waste incineration plants. The test results indicate that austenitic alloys containing higher concentrations of [Cr + Ni + Mo] show excellent corrosion resistant properties and new alloys of JHN24 and HR30M have good corrosion resistance. The different corrosion rate found for each of the three plants could be explained by differences in the severity of corrosion factors, such as, gas temperature, ...

1997-08-01

156

Effect of pitting corrosion on local strength of hold frames of bulk carriers (1st report)  

Energy Technology Data Exchange (ETDEWEB)

Firstly, pitting corrosion observed on hold frames in cargo holds of bulk carriers which exclusively carry coal and iron ore has been investigated in detail. It was shown that the shape of the corrosion pits observed on them is a circular cone and the ratio of the diameter to the depth is in the range between 8 to 1 and 10 to 1, which is different from the trend observed for the bottom shell of the oil tanker where the ratio is in the range between 4 to 1 and 6 to 1. Secondly, a series of tensile tests has been conducted to investigate the effect of pitting corrosion on tensile strength of members. It was pointed out that the tensile strength decreases gradually and the total elongation decreases drastically with the increase of the thickness loss due to pitting corrosion. The reduction of the tensile strength of the members with pitting corrosion is larger than ...

2004-09-01

157

Pitting and stress corrosion cracking resistance of friction stir welded AA 5083  

Energy Technology Data Exchange (ETDEWEB)

The corrosion behaviour of friction stir welded (FSW) joints of AA 5083 has been compared to that of MIG welded joints. Pitting and stress corrosion cracking (SCC) resistance in 3.5% NaCl + 0.3 g/l H{sub 2}O{sub 2} and in EXCO (4 M KCl + 0.5 M KNO{sub 3} + 0.1 M HNO{sub 3}) solutions has been determined at 25 C. SCC susceptibility was evaluated by slow strain rate tests (SSRT), at a strain rate of 1 x 10{sup -6}s{sup -1}. Welds obtained by FSW technique showed a higher corrosion resistance in EXCO solution and a lower pitting tendency than the base alloy. Electrochemical measurements (corrosion potential measurements, polarization curves recording) evidenced that FSW weld was cathodic to base alloy. FSW joints were not susceptible to SCC in both test solutions, whereas MIG joints cracked in both solutions. (orig.)

2001-11-01

158

Corrosion behavior of materials at high temperature by environmental oxidants containing sulfur derivatives: effects of aggressive phase composition on experimental alloys. Final report  

Energy Technology Data Exchange (ETDEWEB)

For a better understanding of sulphidation mechanisms, some alloys (alloy 600, alloy 800, Uranus S, iron-chromium-aluminium-alloy) and metals (iron, chromium, nickel, molybdenum, titanium) were tested at 773, 873, 1 073 K in gaseous sulphur dioxide. Total pressure was 760 torrs. Sulphur dioxide pressure was 760, 100 and 10 torrs. Argon, oxygen, water vapor were used, successively, as pressure complement. Oxygen supply, generally speaking cause decay of corrosion resistance in SO/sub 2/ atmospheres especially at 1 073 K with low ratio p/sub O2//P/sub SO/sub 2//. Water vapor supply act similarly. Temperature laws and pressure laws do not give monotonous rise of corrosion values. There are maximas suggesting corrosion products undertaking a volatilization process. According to test conditions, Uranus S, chromium, alloy 800 (and titanium at some extent) showed good ...

1981-01-01

159

A study of the corrosion of alloy 800 in high-temperature steam  

International Nuclear Information System (INIS)

General corrosion testing of Alloy 800 tube material by the General Electric Co. using out of pile loops with steam temperatures in the range 430 to 770 deg.C and 70 at. pressure with a surface heat flux of 55 W.cm"-"2 and flow velocities of 30 to 60 m.sec"-"1 showed after about 5000 h (a) a relatively moderate loss of metal at a fairly high corrosion rate, (b) a relatively high loss of oxide to the steam phase, and (c) the formation of a zone at the metal surface depleted in chromium by diffusion to the oxide film. It is important to establish whether these results for Alloy 800 were typical of those to be expected under heat transfer, and whether they could be used as a basis for extrapolation to the higher heat fluxes and longer exposure time relevant to superheat applications. Additional corrosion tests in superheated steam of 1000 h duration under isothermal conditions were ...

160

Development of a solvent extraction process for cesium removal from SRS tank waste  

International Nuclear Information System (INIS)

An alkaline-side solvent extraction process was developed for cesium removal from Savannah River Site (SRS) tank waste. The process was invented at Oak Ridge National Laboratory and developed and tested at Argonne National Laboratory using singlestage and multistage tests in a laboratory-scale centrifugal contactor. The dispersion number, hydraulic performance, stage efficiency, and general operability of the process flowsheet were determined. Based on these tests, further solvent development work was done. The final solvent formulation appears to be an excellent candidate for removing cesium from SRS tank waste.

2001-06-30

161

Analysis of WWER 440 SG primary collector bolted joint damage  

Energy Technology Data Exchange (ETDEWEB)

The susceptibility of CHN35VT-VD and 08CH18N10T stainless steels to stress corrosion cracking in water environment, simulating water solution found in threaded holes, was investigated using rising load line displacement tests of precracked C(T) specimens. To judge the role of oxidant on stress corrosion cracking of both stainless steels, the effect of dissolved oxygen content (fully deaerated water, water aerated at the beginning of the test) was studied. 7 refs.

1997-12-31

162

NASA SBIR/STTR Technologies  

Science.gov (United States)

(e.g. enclosed cooktop with built in emissions capture and treatment) . " Test hardware in laboratory, reduced pressure and analog habitat. " Objective 1. ...

163

NASA - A Cosmic Inkblot Test  

Science.gov (United States)

material may survive intact and mix back into interstellar gas clouds, helping to fuel the next generation of stars. NASA's Jet Propulsion Laboratory, Pasadena, Calif.,...

2011-08-10

164

Laboratory Description of Harbor Idealized Tests. Volume 1 ...  

Science.gov (United States)

... modules 2 and 3, 45 ft from each end) in a ... The toe of the stone revetment was 2 ft out from the ... in parentheses are for the current meters in layout 2. ...

1993-03-01

165

Ada Compiler Validation Summary Report: Certificate Number ...  

Science.gov (United States)

... Standards Validation Group National Computer Systems Laboratory National Institute of Standards and Technology ... STANDARD. ... (See test Ci )i3A. ...

1989-08-18

166

Acquired extrahepatic portosystemic shunts in a young dog  

UK PubMed Central (United Kingdom)

AbstractA young, male miniature poodle was presented with severe neurological problems. Laboratory tests and ultrasonograph examination were consistent with extrahepatic portosystemic...Full Text Available

2006-07-01

167

Study on development of multi-composite ceramics  

Energy Technology Data Exchange (ETDEWEB)

Creation of new multi-composite materials is an essential issue to attain an innovative improvement of the current nuclear technology. In this paper, some highlights are focused on the research of creation of those materials and the relating subjects in NIRIM. (1) The KOH corrosion test method are expected to be efficiently available in the limited cases instead of Na corrosion test one. (2) The preliminary creation of the multi-composite ceramics were achieved by Y- ion implantation into sapphire and the RF sputtering, of which the specified orientation was realized by the existence of the buffer layer. The importance of the defect control are described with the relation to the corrosion resistance improvement. (3) The ion beam induced phenomena have been investigated on the surface change of silica glass and the crystallization of Cu film on SrTiO{sub 3}. (4) The electronic states ...

1996-03-01

168

Inhibitor effect on corrosion of titanium alloys in muriatic solutions of titanium-magnesium production  

International Nuclear Information System (INIS)

Corrosion tests of titanium alloys VTI-0, OT4, VT5-1 and steel Kh18N1OT in 10% and 18% HCl with additions of carnallite at 40 deg C have been carried out. It has been established that titanium alloys in 10% and 18% HCl containing 5 and 10% carnallite are sufficiently corrosion resistant in the presence of 0.1-1% FeCl or HNO_3 and can be used for manufacturing the equipment of recirculation gas scrubbers. Steel Kh18N10T is unstable in all the media tested. It is subjected to intensive pitting. Specimens of steel Kh18N10T have also revealed edge cracking.

169

Corrosion results on alternative support materials from two model steam generator tests  

International Nuclear Information System (INIS)

The objective of the C-E/EPRI project, ''Alternative Steam Generator Materials and Designs,'' was to evaluate the corrosion behavior of contemporary or alternative steam generator materials under prototypic design and secondary fault (high contaminant) water conditions. Two model steam generators built with various support materials and designs were tested under representative thermal and hydraulic conditions. One model operated under seawater faulted all-volatile treatment (AVT) secondary water chemistry conditions. The other model operated under acidified fresh water faulted AVT conditions. This presentation focuses on the tube support and tubesheet corrosion results obtained by destructive examination of both models.

1985-03-01

170

Application of new corrosion-resistance superheater tubings for a 500 C, 100 Kgf/cm{sup 2}{center_dot}g high-efficiency waste-to-energy plant  

Energy Technology Data Exchange (ETDEWEB)

A two-year demonstration run of a 500 C/100kgf/cm{sup 2}{center_dot}g high-efficiency waste-to-energy pilot plant has been started from February 1998; this plant represents as the final stage of the NEDO project of development of a high-efficiency waste-to-energy plant. Alloy 625 (SB444) and 310 HCbN tubings were selected for the 3rd and 2nd superheater of the pilot plant, respectively, and ten kinds of conventional and new solid-wall tubings, weld overlayed tubings, composite tubings, and cermet spray coated tubings were tested. By means of 6000-hour field corrosion test in three typical domestic plants, material life and corrosion environment for superheater tubings installed in the pilot plant were evaluated. Also, the effect of alloying elements Cr, Ni, Mo, corrosion rate law, etc. were investigated in detail. Furthermore, the design conception and basic performance of the pilot ...

1999-11-01

171

Survey of degradation modes of candidate materials for high-level radioactive-waste disposal containers  

International Nuclear Information System (INIS)

Three copper-based alloys, CDA 102 (oxygen-free, high-purity copper), CDA 613 (aluminum bronze), and CDA 715 (Cu-30Ni), are candidates for the fabrication of high-level radioactive-waste disposal containers. Waste will include spent fuel assemblies from reactors as well as borosilicate glass, and will be sent to the prospective repository site at Yucca Mountain in Nye County, Nevada. The decay of radionuclides will result in the generation of substantial heat and in fluxes of gamma radiation outside the containers. In this environment, container materials might degrade by atmospheric oxidation, general aqueous phase corrosion, localized corrosion (LC), and stress corrosion cracking (SCC). This volume is a critical survey of available data on pitting and crevice corrosion of the copper-based candidates. Pitting and crevice corrosion are two of the most common forms of LC of these ...

1991-07-01

172

Metal cation inhibitors for controlling denting corrosion in steam generators. Final report. [PWR  

Science.gov (United States)

Metal cations of arsenic, antimony, tin, manganese, zinc, cadmium, indium, and thallium have been evaluated in a preliminary way as possible3 inhibitors for controlling denting corrision observed in steam generators used with pressurized water reactors (PWR). The rationale for this approach was based upon the well-known inhibition effects of metal cations on corrosion rates in electrolyte/metal systems. A review of corrosion inhibition by metal cations (H. Leidheiser, Jr., Corrosion 36, 339 (1982)) has identified eleven inhibition mechanisms. The major test methods used for this evaluation were: (1) Isothermal capsule tests of carbon/steel/Inconel 600 tube bulging rates at temperatures up to 288/sup 0/C in seawater/copper-nickel chloride bulge-accelerating solutions. (2) Immersion weight-loss tests of steel coupled to Inconel 600 in boiling (102/sup 0/C) 3% ...

1982-12-01

173

Electrochemical roles of precipitates on uniform corrosion and hydrogen pickup of zirconium alloys, 2. Roles on hydrogen pickup  

Energy Technology Data Exchange (ETDEWEB)

Substantial roles of precipitates such as Zr-Fe-Cr type intermetallic compounds on uniform corrosion and hydrogen pickup of zirconium alloys in pure water autoclave tests were investigated from an electrochemical point of view. In the previous paper, corrosion mechanism was elucidated by the anodic protection-precipitates degradation model. This paper describes the roles on hydrogen pickup. 633 K pure water autoclave test was performed on high purity zirconium, Zr-0.2Fe, Zr-0.2Cr, and Zr-0.1Fe-0.1Cr alloys. Hydrogen analysis after the corrosion test showed that hydrogen pickup ratio of Zr-0.2Fe alloy was about 80%. It was much higher than about 30% of pure Zr and about 10% of both Zr-0.2Cr and Zr-0.1Fe-0.1Cr alloys. Larger hydrogen content was introduced into Zr-0.2Fe alloy than the other ones by the cathodic hydrogen charging under coulombic equivalence. The ...

2000-08-01

174

Electrochemical roles of precipitates on uniform corrosion and hydrogen pickup of zirconium alloys, 2. Roles on hydrogen pickup  

International Nuclear Information System (INIS)

Substantial roles of precipitates such as Zr-Fe-Cr type intermetallic compounds on uniform corrosion and hydrogen pickup of zirconium alloys in pure water autoclave tests were investigated from an electrochemical point of view. In the previous paper, corrosion mechanism was elucidated by the anodic protection-precipitates degradation model. This paper describes the roles on hydrogen pickup. 633 K pure water autoclave test was performed on high purity zirconium, Zr-0.2Fe, Zr-0.2Cr, and Zr-0.1Fe-0.1Cr alloys. Hydrogen analysis after the corrosion test showed that hydrogen pickup ratio of Zr-0.2Fe alloy was about 80%. It was much higher than about 30% of pure Zr and about 10% of both Zr-0.2Cr and Zr-0.1Fe-0.1Cr alloys. Larger hydrogen content was introduced into Zr-0.2Fe alloy than the other ones by the cathodic hydrogen charging under coulombic equivalence. The ...

2000-08-01

175

Influence of thermal aging on the intergranular corrosion resistance of types 304LN and 316LN stainless steels  

International Nuclear Information System (INIS)

Intergranular corrosion (IGC) resistance of types 304LN and 316LN stainless steels (SS) thermally aged at 823, 873, and 923 K for various durations was assessed by ASTM A262 practice A test (electrolytic etch test) and electrochemical potentiodynamic reactivation (EPR) test. The results indicated that the type 316LN SS has significantly improved IGC resistance compared to 304LN SS. Based on the results of these tests, time-temperature-sensitization (TTS) diagrams were developed for both alloys. The secondary precipitates formed during thermal aging treatments were electrochemically extracted and analyzed by X-ray diffraction (XRD) to determine the types of precipitates formed during the aging treatments. The results indicated that the precipitates were mostly of M_2_3C_6 carbides.

1996-01-01

176

Influence of thermal aging on the intergranular corrosion resistance of types 304LN and 316LN stainless steels  

International Nuclear Information System (INIS)

Intergranular corrosion (IGC) resistance of types 304LN and 316LN stainless steels (SS) thermally aged at 823, 873, and 923 K for various durations was assessed by ASTM A262 practice A test (electrolytic etch test) and electrochemical potentiodynamic reactivation (EPR) test. The results indicated that the type 316LN SS has significantly improved IGC resistance compared to 304LN SS. Based on the results of these tests, time-temperature-sensitization (TTS) diagrams were developed for both alloys. The secondary precipitates formed during thermal aging treatments were electrochemically extracted and analyzed by X-ray diffraction (XRD) to determine the types of precipitates formed during the aging treatments. The results indicated that the precipitates were mostly of M_2_3C_6 carbides.

177

Effect of alloying elements on intergranular corrosion susceptibility of Mo contained austenitic stainless steel in nitric acid solution  

International Nuclear Information System (INIS)

In this study, effects of alloying elements such as Mo, Cr and Ni on intergranular corrosion (IGC) resistance of Mo contained austenitic stainless steels in boiling 65% nitric acid solution (Huey Test) were studied. Obtained results are as follows; (1) Mo deteriorates IGC resistance of austenitic stainless steel in Huey test due to enhance precipitation of Laves ((Fe, Cr)_2Mo) phase at grain boundary. (2) Cr improves IGC resistance of Mo contained austenitic stainless steel in Huey test, which is considered to reduce dissolution rate of Laves phase into nitric acid solution by increasing Cr content in Laves phase as increasing Cr content of stainless steel. (3) Ni suppresses occurrence of IGC of Mo contained austenitic stainless steel in Huey test. (author).

1995-01-01

178

EDF approach on OD corrosion of SG tubes  

Energy Technology Data Exchange (ETDEWEB)

The secondary side corrosion of steam generator tubes is the main degradation of components in operating power plants, strongly impacted by chemistry. This is why EDF has largely studied the chemical parameters in its 56 PWRs which might influence corrosion development. The results of 168 hideout returns of chemical species performed on the French plants allowed to draw conclusions on where chemical species are likely to concentrate in steam generators and on the influence of several contaminants on corrosion processes: sodium, chloride, phosphate, organic compounds, etc... Based on laboratory studies and plants feedback, new chemistry specifications were established and are now applied to EDF units to minimize corrosion and operating costs and to provide a good availability while maintaining an excellent safety. Boric acid is added in the secondary water of the 10 oldest units with ...

1998-12-31

179

Corrosion tests of high-alloy, stainless steels and nickel-chromium-molybdenum alloys under conditions typically encountered in the evaporation of flue gas desulfurization (FGD) scrubber solutions. Final report. Korrosionsuntersuchungen an hochlegierten nichtrostenden Staehlen und Nickel-Chrom-Molybdaen-Legierungen unter Eindampfbedingungen von Abwaessern aus Rauchgasentschwefelungsanlagen. Schlussbericht  

Energy Technology Data Exchange (ETDEWEB)

For evaporation crystallization of extremely corrosive FGD scrubber solutions which - depending on the process - can lead all the way to a product suitable for depositing, an economic equipment concept based on metallic construction materials was to be investigated. In a parameter study, electrochemical test methods were used to determine the influence of the pH value, the Fe{sup 3+}, F and So{sub 2} contents in a solution containing 200 g/l CaCl{sub 2}+30 g/l NaCl at 80deg C on the resistance to pitting corrosion of stainless steels and NiCrMo alloys. In addition, electrochemical and wet corrosion tests (e.g. crevice corrosion) were conducted using original FGD scrubber solutions with 43-50% dry substance from the power plants Reuter-West, Oberhavel and Rudow of the BEWAG, Berlin. The results were compared to those of standardized and non-standardized ...

1991-08-05

180

Enhanced corrosion resistance by sol-gel-based ZrO_2-CeO_2 coatings on magnesium alloys  

International Nuclear Information System (INIS)

The physical, chemical and mechanical properties of magnesium alloys make them attractive materials for automotive and aerospace applications. However, these materials are susceptible to corrosion and wear. This work discusses the potential of using sol-gel based coatings consisting of ZrO_2 and 15 wt.% of CeO_2. The CeO_2 component provides enhanced corrosion protection, while ZrO_2 impart corrosion as well as wear resistance. Coating deposition was performed by the dip coating technique on two magnesium alloy substrates with different surface finishes: AZ91D (as-casted, sand-blasted, and machined) and AZ31 (rolled and machined). All as-deposited coatings (xerogel coatings) were then subjected to 10 h annealing: a temperature of 180 C was applied to the AZ91D alloy and 140 C to the AZ31 alloy. Morphological and structural properties of the annealed coatings were investigated by scanning electron microscopy, atomic force ...

2005-02-01

181

Results of the Interlaboratory Exercise CSN/CIEMAT-100 Among Environmental Radioactivity Laboratories (Soil); Resultados del Ejercicio Interlaboratorios de Radiactividad Ambiental CSN/CIEMAT-00 (Suelo)  

Energy Technology Data Exchange (ETDEWEB)

The document describes the outcome of the CSN/CIEMAT-00 interlaboratory test comparison among environmental radioactivity laboratories. the exercise was organised according to the ISO-43 and the ISO/IUPAC/AOAC Harmonized Protocol for the proficiency testing of analytical laboratories. the test sample was a soil containing environmental levels of K-40, Ra-226, Ac-228, Sr-90, Cs-137, Cs-134, Pu (239-240) y Am-241. the Universidad Autonoma de Barcelona prepared the material and reported adequate statistical studies of homogeneity. The results of the exercise were computed for 30 participating laboratories, and their analytical performance was assessed using the u-score approach. A raised percentage of satisfactory laboratory performance has been obtained for all the analysis, being the best performance in gamma measurements. The exercise has ...

2002-07-01

182

Evaluation of broth disk elution methods for susceptibility testing of anaerobic bacteria with the newer beta-lactam antibiotics.  

UK PubMed Central (United Kingdom)

Broth disk elution procedures represent one of the most practical means for clinical laboratories to perform routine antibiotic susceptibility tests on anaerobic bacteria. The accuracy of five disk...Full Text Available

1986-03-01

183

How do we impact corrosion?  

Science.gov (United States)

Page 1. How do we impact corrosion? US Army Corrosion Summit Feb. ... Page 4. Leaders in Corrosion Control Technology Impact of Corrosion - $$ ...

2009-02-03

184

Initial efforts to evaluate the corrosion problems in the infrastructure of Mexican southeast coastal zones  

Energy Technology Data Exchange (ETDEWEB)

The infrastructure of the Mexican southeastern coastal zone is affected by corrosion problems which are due, mainly, to the construction bad practices and to the aggressive environmental agents (temp., Relative Humidity, chlorides). The first actions for knowing and controlling them have been taken on the coast of Progreso, Yucatan. Cylinders of solid concrete and others with an embedded rebar were constructed and exposed to the marine environment studying different variables like w/c ratio, time of curing, coated and uncoated rebars, chlorides and CO{sub 2} penetration and place of exposure with respect to the seashore. The cylinders were tested through corrosion potential and polarization resistance measurements in order to detect, in a first stage, the onset and propagation stages of the corrosion processes and to correlate the apparent corrosion current density (Icorr.) with the ...

1995-10-01

185

Laboratory directed research and development program, FY 1996  

Energy Technology Data Exchange (ETDEWEB)

The Ernest Orlando Lawrence Berkeley National Laboratory (Berkeley Lab) Laboratory Directed Research and Development Program FY 1996 report is compiled from annual reports submitted by principal investigators following the close of the fiscal year. This report describes the projects supported and summarizes their accomplishments. It constitutes a part of the Laboratory Directed Research and Development (LDRD) program planning and documentation process that includes an annual planning cycle, projection selection, implementation, and review. The Berkeley Lab LDRD program is a critical tool for directing the Laboratory`s forefront scientific research capabilities toward vital, excellent, and emerging scientific challenges. The program provides the resources for Berkeley Lab scientists to make rapid and significant contributions to critical national science and technology problems. The LDRD program also ...

1997-02-01

186

Fate of corrosion products released from stainless steel in marine sediments and seawater. Part 3. Calcareous ooze  

International Nuclear Information System (INIS)

The physicochemical forms and partitioning of corrosion products released from stainless steel upon exposure to selected environmental conditions is the subject of this investigation. This report describes the influence of calcareous sediment on the rate of release and fate of corrosion products produced when neutron-activated stainless steel specimens were exposed to a Globigerina ooze taken from the Northeast Pacific Ocean. The calcareous ooze used in this study consists largely of planktonic formanifera tests and was found to be about 90% CaCO_3. The trace metal content of this sediment was typical of average deep-sea carbonate sediments, and the ratios of trace elements to Ti were not remarkably different from a coastal clayey silt or a Northeast Pacific pelagic red clay. Most (>80%) of the trace metals extracted by sequential chemical treatment were associated with reductant-soluble materials, i.e., amorphous Mn and ...

187

Results of the remote sensing feasibility study for the uranium hexafluoride storage cylinder yard program  

Energy Technology Data Exchange (ETDEWEB)

The US DOE manages the safe storage of approximately 650,000 tons of depleted uranium hexafluoride remaining from the Cold War. This slightly radioactive, but chemically active, material is contained in more than 46,000 steel storage cylinders that are located at Oak Ridge, Tennessee; Paducah, Kentucky; and Portsmouth, Ohio. Some of the cylinders are more than 40 years old, and approximately 17,500 are considered problem cylinders because their physical integrity is questionable. These cylinders require an annual visual inspection. The remainder of the 46,000-plus cylinders must be visually inspected every four years. Currently, the cylinder inspection program is extremely labor intensive. Because these inspections are accomplished visually, they may not be effective in the early detection of leaking cylinders. The inspection program requires approximately 12--14 full-time-equivalent (FTE) employees. At the cost of approximately $125K per FTE, this translates to $1,500K per annum just ...

1997-02-01

188

Environmentally assisted cracking in light water reactors. Semiannual report, October 1993--March 1994. Volume 18  

International Nuclear Information System (INIS)

This report summarizes work performed by Argonne National Laboratory (ANL) on fatigue and environmentally assisted cracking (EAC) in light water reactors (LWRs) during the six months from October 1993 to March 1994. EAC and fatigue of piping, pressure vessels, and core components in LWRs are important concerns in operating plants and as extended reactor lifetimes are envisaged. Topics that have been investigated include (a) fatigue of low-alloy steel used in piping, steam generators, and reactor pressure vessels, (b) EAC of wrought and cast austenitic stainless steels (SSs), and (c) radiation-induced segregation and irradiation-assisted stress corrosion cracking (IASCC) of Type 304 SS after accumulation of relatively high fluence. Fatigue tests have been conducted on A302-Gr B low-alloy steel to verify whether the current predictions of modest decreases of fatigue life in simulated pressurized water reactor water are valid ...

2007-09-01

189

Durability of bare and anodised aluminium in atmosphere of very different corrosivities I. Bare aluminium; Durabilidad del aluminio desnudo y anodizado en atmosferas de muy diferentes corrosividades. I. Aluminio desnudo  

Energy Technology Data Exchange (ETDEWEB)

The behaviour of bare aluminium is studied in atmospheric exposure at 11 natural testing stations with salinity levels ranging between 2.1 and 684 mg Cl''- m''-2 d''-1. In atmospheres of low or moderate aggressivity aluminium behaves as a passive material, though the insignificant corrosion that is produced is sufficient to spoil its appearance. In contrast, at salinity levels of 50 mg Cl''- m''-2 ''-1 or above, aluminium is susceptible to pitting corrosion even in the first year of atmospheric exposure, or in the second year at salinities of {<=} 10 mg Cl''- m''-2 d''-1. For comparative purposes, results are included for aluminium protected with an anodic film of 28 {mu}m thickness exposed at the same testing stations. A 28 {mu}m anodic ...

2004-07-01

190

Anodic protection provided by precipitates in aqueous corrosion of Zircaloy  

Energy Technology Data Exchange (ETDEWEB)

Alloying elements such as Fe and Cr are generally considered to be effective even in small quantities for corrosion resistance of Zircaloy-4. The maximum total solubility of Fe + Cr in a Zr-Sn matrix has been reported to be very low. Therefore, most of these elements are observed in the form of ternary Zr-Fe-Cr-type precipitates. To clarify the effects of precipitates on corrosion property, Zr-1.3 Sn-(Fe,Cr) alloys containing Fe + Cr from 45 up to 180 ppm (the Fe to Cr ratio is about 2) were melted from pure zirconium (X-bar Zr and EB-Zr) and pure alloying elements. They were subjected to corrosion testing in 633 K water and microstructural analysis. It was found that precipitate-free materials showed much larger weight gains than precipitate-containing materials even at the same alloy compositions. Subsequently, a corrosion test on the precipitate-free material ...

1996-12-31

191

Anodic protection provided by precipitates in aqueous corrosion of Zircaloy  

International Nuclear Information System (INIS)

Alloying elements such as Fe and Cr are generally considered to be effective even in small quantities for corrosion resistance of Zircaloy-4. The maximum total solubility of Fe + Cr in a Zr-Sn matrix has been reported to be very low. Therefore, most of these elements are observed in the form of ternary Zr-Fe-Cr-type precipitates. To clarify the effects of precipitates on corrosion property, Zr-1.3 Sn-(Fe,Cr) alloys containing Fe + Cr from 45 up to 180 ppm (the Fe to Cr ratio is about 2) were melted from pure zirconium (X-bar Zr and EB-Zr) and pure alloying elements. They were subjected to corrosion testing in 633 K water and microstructural analysis. It was found that precipitate-free materials showed much larger weight gains than precipitate-containing materials even at the same alloy compositions. Subsequently, a corrosion test on the precipitate-free material ...

1995-09-11

192

Load conditions and corrosion fatigue crack propagation behavior of high performance steel under seawater environment  

Energy Technology Data Exchange (ETDEWEB)

An effect of load conditions on Corrosion Fatigue Crack Propagation (CFCP) behavior of High Performance Steel (HPS) under seawater environment was investigated. Fatigue crack propagation tests under several load conditions including stress ratio and load frequency were conducted in air and 3.5% NaCl solution environments. Corrosion/fatigue ratio factor, C/F, particularly was defined to analyze the effect of such conditions. As shown in the results, a decrease of load ratio and frequency leads to an increase of C/F factor. Consequently, under lower loading frequency and stress ratio, the seawater condition causes much more significant effect on CFCP behavior of HPS.

2009-07-01

193

Influence of organic additives on the corrosion of iron-based amorphous alloys in dilute sulfuric acid solution  

Energy Technology Data Exchange (ETDEWEB)

Some N-containing or S-containing organic substances and some acetylenic alcohols were tested as inhibitors of the corrosive attack suffered by Fe-based metallic glasses in deaerated 0.1 N sulfuric acid (H{sub 2}SO{sub 4}) solution at 25 C. It was verified that the specific action these compounds exerted on the corrosion process of the amorphous alloys was similar to the one these compounds exerted on polycrystalline iron. The most efficient substances were those containing a sulfur atom with available lone pairs, which chiefly inhibited the anodic reaction of both metal specimens. Owing to the chemical and physical homogeneity of the amorphous alloy, the chemisorbed inhibitor film that formed on the glassy surface was more stable and protective than that formed on the polycrystalline iron.

1999-07-01

194

Study on the interface of PVDF coatings and HF-treated AZ31 magnesium alloy: Determination of interfacial interactions and reactions with self-healing properties  

International Nuclear Information System (INIS)

Research highlights: ? Reports a high protection system for the alloy in corrosive environment. ? Describes an interfacial process with self-healing properties. ? Reports the influence of substrate pre-treatment in the coating performance. - Abstract: In this paper the interface of poly(vinylidene fluoride) coatings prepared by the dip coating method and HF-treated AZ31 magnesium alloy was evaluated. The best performance of this system in corrosion tests compared to ground, as-received and acetic acid cleaned substrates is related to an acid-base interaction at the interface and to interfacial reactions which resulted in a self-healing process. The protectiveness of the samples was investigated using impedance and immersion tests while the coating morphology and interface stability were investigated by scanning electron microscopy, X-ray photoelectron spectroscopy and adhesion ...

2011-02-01

195

SCC mitigation method for BWR materials by TiO2 technique  

International Nuclear Information System (INIS)

TiO2 addition into boiling water reactor (BWR) primary system is being developed as a method to mitigate stress corrosion cracking (SCC) of the BWR structural materials. This technique aims for electrochemical corrosion potential (ECP) decrease of reactor materials by photo-excitation reaction under Cherenkov irradiation. ECP measurement tests have been conducted in the test loop in BWR to investigate the feasibility of the SCC mitigation method with TiO2. The test results showed that the ECP of TiO2 deposited materials was decreased to 2 technique was confirmed to be feasible as a SCC mitigation method for BWR structural materials without hydrogen injection. (author)

2008-10-13

196

Inhibiting pitting corrosion in carbon steel exposed to dilute radioactive waste slurries  

Energy Technology Data Exchange (ETDEWEB)

Dilute caustic high-level radioactive waste slurries can induce pitting corrosion in carbon steel. Cyclic potentiodynamic polarization tests were conducted in simulated and actual waste solutions to determine minimum concentrations of sodium nitrate which inhibit pitting in ASTM A537 class 1 steel exposed to these solutions. Susceptibility to pitting was assessed through microscopic inspection of specimens and inspection of polarization scans. Long-term coupon immersion tests were conducted to verify the nitrite concentrations established by the cyclic potentiodynamic polarization tests. The minimum effective nitrite concentration is expressed as a function of the waste nitrate concentration and temperature.

1991-01-01

197

The use of water-soluble hydrazones as inhibitors for the corrosion of C-steel in acidic medium  

Energy Technology Data Exchange (ETDEWEB)

Inhibition efficiency of some water-soluble hydrazones for C-steel corrosion in hydrochloric acid has been tested by weight loss, polarisation measurements and open circuit technique. The inhibition effect was attributed to the adsorption of the additives on the C-steel surface as supported by adsorption measurements at Pt electrode using cyclic voltammetry. Electrochemical measurements indicated that all the additives behave as cathodic-type inhibitors. The data obtained fit well to both the Temkin adsorption isotherm and the kinetic-thermodynamic model. The inhibition behaviour and its order were explained with the help of the proposed skeletal representation.

2007-09-15

198

Testing of 12Kh18N10T tube steel samples tendency to intergranular corrosion  

International Nuclear Information System (INIS)

Tendency of 12Kh18N10T steel tube samples to intergranular corrosion (IGC) is investigated by an express electrochemical method in the 10% solution of H_2SO_4+0.0025 g/l of KCNS. Tendency to IGC is mainly detected on the internal surface of tube samples. It is shown that the tendency to INC under plant conditions is caused by surface carburization under its incomplete purification from the graphite lubrication.

1993-01-01

199

Surface modification of 17-4PH stainless steel by DC plasma nitriding and titanium nitride film duplex treatment  

Energy Technology Data Exchange (ETDEWEB)

17-4PH stainless steel was modified by direct current (DC) plasma nitriding and titanium nitride film duplex treatment in this study. The microstructure, wear resistance and corrosion resistance were characterized by X-ray diffraction (XRD), pin-on-disk tribological test and polarization experiment. The results revealed that the DC plasma nitriding pretreatment was in favor of improving properties of titanium nitride film. The corrosion resistance and wear resistance of duplex treatment specimen was more superior to that of only coated titanium nitride film.

2007-04-15

200

Surface modification of 17-4PH stainless steel by DC plasma nitriding and titanium nitride film duplex treatment  

International Nuclear Information System (INIS)

17-4PH stainless steel was modified by direct current (DC) plasma nitriding and titanium nitride film duplex treatment in this study. The microstructure, wear resistance and corrosion resistance were characterized by X-ray diffraction (XRD), pin-on-disk tribological test and polarization experiment. The results revealed that the DC plasma nitriding pretreatment was in favor of improving properties of titanium nitride film. The corrosion resistance and wear resistance of duplex treatment specimen was more superior to that of only coated titanium nitride film.

2007-04-01

201

Intergranular corrosion of Alloy 800 by the electrochemical potentiokinetic reactivation method  

Energy Technology Data Exchange (ETDEWEB)

The 'Electrochemical Potentiokinetic Reactivation' method has been employed to quantify the degree of intergranular corrosion of Alloy 800, with different Ti + Al content, aged in the range 500-650/sup 0/C for times up to 5000 hours. The results were compared with the classical Rollason's curves obtained by means of the Strauss' test and a satisfactory agreement was found. An explanation of the slight differences between both methods has been proposed on the basis of the passivity film morphology.

1981-08-01

202

Electrochemical behavior of nickel in nitric acid and its corrosion inhibition using some thiosemicarbazone derivatives  

British Library Electronic Table of Contents (United Kingdom)

The adsorption and corrosion inhibition behavior of three selected thiosemicarbazone derivatives, namely 3-pyridinecarboxaldehyde thiosemicarbazone (META), isonicotinaldehyde thiosemicarbazone (PARA) and 2-pyridinecarboxaldehyde thiosemicarbazone (ORTHO) at the nickel surface were studied electrochemically by Tafel and impedance methods and computationally by carrying out Monte Carlo searches of configurational space on nickel/thiosemicarbazone derivative system. Electrochemical measurements showed that the inhibition efficiency of these compounds increased with increase in their concentration. The recorded inhibition efficiencies of the three tested thiosemicarbazone increase in the order: META>PARA>ORTHO. Polarization studies showed that these compounds act as mixed-type inhibitors for n...

2010-01-01

203

A correlation between electrochemical parameters and stress corrosion cracking of alloy 600 in high temperature caustic solution  

International Nuclear Information System (INIS)

The properties of the passive films formed on Alloy 600 at different applied potentials in 10% NaOH solution at 315 .deg. C was studied using in situ AC impedance and polarization measurements. The results were correlated with the stress corrosion cracking (SCC) behavior obtained from the C-ring tests in the same conditions. The change of the semiconductive property and the peak of relaxation time were observed at 0.2 V where the SCC rate showed a maximum. These results were also consistent with the prediction parameter for SCC obtained from fast and slow polarization scans.

2001-10-01

204

Multi-centre evaluation of the urine test strip analyser Rapimat.  

Science.gov (United States)

A multi-centre evaluation of the test strip analyser, Rapimat, was performed by four laboratories following the ECCLS 2nd draft guidelines for the evaluation of analysers in clinical chemistry. Using the Rapignost urine test strip with the test fields for bilirubin, urobilinogen, acetoacetate, ascorbic acid, glucose, protein, nitrite, pH and haemoglobin, the Rapimat was found to be analytically reliable in comparison with other, in most cases quantitative procedures. During the observation period of about 6 months no breakdown occurred in any laboratory. Interferences and sensitivity as discussed for the bilirubin and urobilinogen test field are more related to the test strip than to the instrument. Several improvements for further developments are suggested. This multi-centre study has shown that the ECCLS protocol is applicable to ...

1985-08-01

205

Thermal conductivity of polyisocyanurate foam board insulation blown with CFC-11 substitutes: Laboratory and long-term field measurements  

Energy Technology Data Exchange (ETDEWEB)

This paper reports on a series of laboratory and controlled test site measurements of the thermal conductivity of polyisocyanurate foam laminated boardstock roof insulations produced with several different blowing agents; CFC-11, HCFC-123, HCFC-14lb, and two blends of the HCFCs. The behavior of the experimental foams with HCFCs is compared to that of conventional polyisocyanurate foam blown with CFC-11. Thermal drift observed from two years of field exposure is compared to laboratory accelerated aging tests and the laboratory and field measurement techniques are described. This work is part of a Joint Industry/Government Project established in the United States to evaluate the technical viability of HCFC alternative blowing agents for polyisocyanurate foam roof insulations.

1992-01-01

206

Airbags to Martian Landers: Analyses at Sandia National Laboratories  

Energy Technology Data Exchange (ETDEWEB)

A new direction for the national laboratories is to assist US business with research and development, primarily through cooperative research and development agreements (CRADAs). Technology transfer to the private sector has been very successful as over 200 CRADAs are in place at Sandia. Because of these cooperative efforts, technology has evolved into some new areas not commonly associated with the former mission of the national laboratories. An example of this is the analysis of fabric structures. Explicit analyses and expertise in constructing parachutes led to the development of a next generation automobile airbag; which led to the construction, testing, and analysis of the Jet Propulsion Laboratory Mars Environmental Survey Lander; and finally led to the development of CAD based custom garment designs using 3D scanned images of the human body. The structural analysis of these fabric structures is ...

1994-03-01

207

Corrosion in waste incineration facilities; Korrosion i avfallsfoerbraenningsanlaeggningar  

Energy Technology Data Exchange (ETDEWEB)

Waste is a heterogeneous fuel, often with high levels of chlorine, alkali and heavy metals. This leads to much more severe corrosion problems than combustion of fossil fuels. The corrosion rates of the materials used can be extremely high. Materials used for heat transferring parts are usually carbon steel or low alloyed steel. These are significantly cheaper than other steels. Austenitic stainless steel is also used, but is often avoided due to its sensitivity to stress corrosion cracking. More advanced materials, such as nickel base alloys, can be used in extremely aggressive environments. Since these materials are expensive and do not always have sufficient mechanical properties, they are often used as coatings on carbon steel tubes or as composite tubes. A new method, which shows good results at the first tests in plants, is electroplating with nickel. Plastic materials can be used in low ...

2004-11-01

208

A newly synthesized glycine derivative to control uniform and pitting corrosion processes of Al induced by SCN"- anions - Chemical, electrochemical and morphological studies  

International Nuclear Information System (INIS)

A newly synthesized glycine derivative (termed GlyD), 2-(4-(dimethylamino)benzylamino)acetic acid hydrochloride, was used to inhibit uniform and pitting corrosion processes of Al in 0.50 M KSCN solutions (pH 6.8) at 25 "oC. For uniform corrosion inhibition study, Tafel extrapolation, linear polarization resistance and impedance methods were used, complemented with SEM examinations. An independent method of chemical analysis, namely ICP-AES (inductively coupled plasma atomic emission spectrometry) was also used to test validity of corrosion rate measured by Tafel extrapolation method. GlyD inhibited uniform corrosion, even at low concentrations, reaching a value of inhibition efficiency up to 97% at a concentration of 5 x 10"-"3 M. Results obtained from the different corrosion evaluation techniques were in good agreement. This new synthesized glycine derivative ...

2010-10-01

209

Laboratory Directed Research and Development (LDRD) on Mono-uranium Nitride Fuel Development for SSTAR and Space Applications  

Energy Technology Data Exchange (ETDEWEB)

The US National Energy Policy of 2001 advocated the development of advanced fuel and fuel cycle technologies that are cleaner, more efficient, less waste-intensive, and more proliferation resistant. The need for advanced fuel development is emphasized in on-going DOE-supported programs, e.g., Global Nuclear Energy Initiative (GNEI), Advanced Fuel Cycle Initiative (AFCI), and GEN-IV Technology Development. The Directorates of Energy & Environment (E&E) and Chemistry & Material Sciences (C&MS) at Lawrence Livermore National Laboratory (LLNL) are interested in advanced fuel research and manufacturing using its multi-disciplinary capability and facilities to support a design concept of a small, secure, transportable, and autonomous reactor (SSTAR). The E&E and C&MS Directorates co-sponsored this Laboratory Directed Research & Development (LDRD) Project on Mono-Uranium Nitride Fuel Development for SSTAR ...

2006-02-09

210

New facility design and work method for the quantitative fit testing laboratory. Master's thesis  

Energy Technology Data Exchange (ETDEWEB)

The United States Air Force School of Aerospace Medicine (USAFSAM) tests the quantitative fit of masks which are worn by military personnel during nuclear, biological, and chemical warfare. Subjects are placed in a Dynatech-Frontier Fit Testing Chamber, salt air is fed into the chamber, and samples of air are drawn from the mask and the chamber. The ratio of salt air outside the mask to salt air inside the mask is called the quantitative fit factor. A motion-time study was conducted to evaluate the efficiency of the layout and work method presently used in the laboratory. A link analysis was done to determine equipment priorities, and the link data and design guidelines were used to develop three proposed laboratory designs. The proposals were evaluated by projecting the time and motion efficiency, and the energy expended working in each design. Also evaluated were the lengths of the equipment links for ...

1989-05-01

211

STRESS CORROSION CRACKING SUSCEPTIBILITY OF HIGH LEVEL WASTE TANKS DURING SLUDGE MASS REDUCTION  

Energy Technology Data Exchange (ETDEWEB)

Aluminum is a principal element in alkaline nuclear sludge waste stored in high level waste (HLW) tanks at the Savannah River Site. The mass of sludge in a HLW tank can be reduced through the caustic leaching of aluminum, i.e. converting aluminum oxides (gibbsite) and oxide-hydroxides (boehmite) into soluble hydroxides through reaction with a hot caustic solution. The temperature limits outlined by the chemistry control program for HLW tanks to prevent caustic stress corrosion cracking (CSCC) in concentrated hydroxide solutions will potentially be exceeded during the sludge mass reduction (SMR) campaign. Corrosion testing was performed to determine the potential for CSCC under expected conditions. The experimental test program, developed based upon previous test results and expected conditions during the current SMR campaign, consisted of electrochemical and mechanical ...

2007-10-18

212

Results of UT training for defect detection and sizing technique using specimens with fatigue crack and SCC  

International Nuclear Information System (INIS)

At the importance increase of UT (ultrasonic testing) with the application of rules on fitness-for-service for nuclear power plants, JAPEIC (Japan power engineering and inspection corporation) started education training for defect detection and sizing technique. Weld joints specimen with EDM (Electro-Discharged Machining) notches, fatigue cracks and intergranular stress corrosion cracks were tested and practiced repeatedly based on a modified ultrasonic method and the defect size measuring accuracy of the trainees was surely improved. Results of the blind test confirmed effectiveness of education training. (T. Tanaka)

2005-04-01

213

Stress corrosion cracking of austenitic stainless steel core internal welds.  

Energy Technology Data Exchange (ETDEWEB)

Microstructural analyses by several advanced metallographic techniques were conducted on austenitic stainless steel mockup and core shroud welds that had cracked in boiling water reactors. Contrary to previous beliefs, heat-affected zones of the cracked Type 304L, as well as 304 SS core shroud welds and mockup shielded-metal-arc welds, were free of grain-boundary carbides, which shows that core shroud failure cannot be explained by classical intergranular stress corrosion cracking. Neither martensite nor delta-ferrite films were present on the grain boundaries. However, as a result of exposure to welding fumes, the heat-affected zones of the core shroud welds were significantly contaminated by oxygen and fluorine, which migrate to grain boundaries. Significant oxygen contamination seems to promote fluorine contamination and suppress thermal sensitization. Results of slow-strain-rate tensile tests also indicate that fluorine exacerbates the ...

1999-04-14

214

Hydrogen evolution and corrosion performance of NiZn coatings  

International Nuclear Information System (INIS)

The hydrogen evolution reaction (HER) was studied on bare brass (B), nickel coated brass (B/Ni), nickel-zinc alloy coated brass (B/NiZn, leached Zn), nickel (under layer)/nickel-zinc alloy coated (top layer) brass electrodes (B/Ni/NiZn, leached Zn) in 1 M NaOH solution using electrolysis, cathodic polarization and electrochemical impedance spectroscopy (EIS) techniques. Long term tests were performed in order to evaluate the electrocatalytic activity and corrosion performance of the prepared electrodes with operation time. The results showed that leached electrodes, especially B/Ni/NiZn electrode, have a smaller overpotential than the others and a good electrocatalytic activity for the HER. Its electrocatalytic activity is also stable over electrolysis time. Contrary to the HER performance, B/NiZn cannot provide an adequate corrosion protection. However, when a thin Ni layer was coated under the NiZn alloy coating ...

2007-02-01

215

Enhancing the corrosion resistance of dentistry drills by plasma immersion nitrogen in implantation of AISI 434-based SS  

Energy Technology Data Exchange (ETDEWEB)

In order to enhance the resistance to the pitting corrosion due to asepsis processes and to avoid structural fractures in dentistry drills, a plasma immersion ion implantation (PIII) treatment using nitrogen has been performed. The selected drill samples, made of AISI 434 based stainless steel with a 0.670 mm diameter, were treated at a -1kV bias between 350 C and 450 C, this temperature being controlled by both a 20-50 {mu}s pulse width and a 200-1000 Hz repetition rate in the bias. The drills were analysed by cyclic potentiodynamic tests showing a good pitting corrosion resistance when treated at around 400 C, as follows from a resulting very low hysteresis loop. Yet, the resistance appears somehow diminished by the presence of sputtering when processed at temperatures near 450 C. It is also found that the PIII nitriding effectiveness appears to be limited by the appearance of uniform corrosion. ...

2007-07-01

216

Effect of substrate temperature on structural properties and corrosion resistance of carbon thin films used as bipolar plates in polymer electrolyte membrane fuel cells  

International Nuclear Information System (INIS)

In this work, the effects of substrate temperature that was changed from 100 to 500 "oC on the structural, chemical and electrical properties of carbon films, prepared by direct current magnetron sputtering technique, on 316L stainless steel as bipolar plate had been investigated. Raman spectroscopy and scanning electron microscopy (SEM) were performed to study the structure and the morphology of the deposited films, respectively. The corrosion resistance and the electrical resistivity were carried out by using corrosion tests and four point-probe technique. The results show that the carbon films change the structure from amorphous to graphite-like by increasing temperatures. At the temperatures higher than 300 "oC, the holes and porosities are formed on the film indicating a decrease of film quality. According to our results, corrosion resistance and electrical properties are depended strongly on the ...

2010-07-23

217

Effect of boron doping in the carbon support on platinum nanoparticles and carbon corrosion  

Energy Technology Data Exchange (ETDEWEB)

Carbon supported catalysts can lose their activity over a period of time due to the sintering of the nanometer-sized catalyst particles. The sintering of metal clusters on carbon supports can occur due to the weak interaction between the metal and the support and also due to the corrosion of carbon, especially in fuel cell electrocatalysts. The sintering may be reduced by increasing the interaction between the metal and the support and also by increasing the corrosion resistance of carbon supports. In an effort to mitigate the growth of the nanoparticles, carbon-substituted boron defects were introduced in the carbon lattice. The interaction between the Pt nanoparticles on the pure and boron-doped carbon supports was examined using X-ray photoelectron spectroscopy (XPS). The results indicate that the interaction between the Pt nanoparticles and the boron-doped carbon support was slightly stronger than the interaction between the Pt ...

2009-07-15

218

Stress corrosion cracking: 1965-1990  

Energy Technology Data Exchange (ETDEWEB)

Advances in the theory and practice of stress corrosion cracking (SCC) are reviewed for the period 1965-1990. The proceedings of two landmark conferences are used as a basis for discussion: Ohio State University (1967) and Kohler, WI (1988). The discussion is developed around the following topics: metal-environment combinations, testing, fractography, metallurgical aspects, electrochemical aspects and crack chemistry, mechanisms, and prediction and mitigation. It is concluded that the main developments since 1967 are the recognition of the lack of specificity of SCC environments, the use of slow strain rate and fracture mechanics testing, quantitative SEM fractography, studies of grain boundary structure and compositions, transient electrochemistry of bare metal surfaces, measurement and modelling of crack chemistry, elaboration of several SCC models, including slip-dissolution and film induced cleavage, and mitigation by ...

1990-01-01

219

Insitu Assessment of Contaminant Containment Systems  

Environmental Research Database

Objectives(1) Evaluate various insitu techniques for determination of the permeability of slurry walls and investigate the extent of material disturbance and fracturing during drilling and testing.~%~~%~(2) Perform laboratory tests of block samples obtained from the field testing site and compare the results with field measurements.~%~~%~(3) Investigate the mechanisms of drilling using a newly developed instrumented self-boring device and develop a theoretical framework for drilling mechanisms in soils.~% [continued...]DescriptionCement-bentonite and clay liner systems are used as components of containment systems by the environmental industry to control the migration of pollution. In the interest of public safety, following construction, there is a requirement to test these structures in orde to assess if they meet the design critetia. At present ...

2006-01-30

220

Optimization of an interlaboratory program for the certification of a multi-element plagiogneiss reference material  

International Nuclear Information System (INIS)

A sample of garnet-biotite plagiogneiss, GBPg-1 is currently being developed as a certified reference material at the Vinogradov Institute of Geochemistry. It was used as the sample that was distributed round 7 of International Proficiency Testing Program (GeoPT7) and was analyzed by 76 geoanalytical laboratories around the world. Twenty Russian laboratories involved in the interlaboratory experiment also analyzed GBPg-1. The resultant analytical data obtained from these two experiments has allowed GBPg-1 to be certified as a state standard sample for 50 elements. It also enabled a comparison of the quality of data developed by the Russian and international geoanalytical laboratories, to optimize the outcome of this interlaboratory experiment.

2003-02-03

221

A combined cycle engine test facility  

Energy Technology Data Exchange (ETDEWEB)

Rocket-Based Combined-Cycle (RBCC) engines intended for missiles and/or space launch applications incorporate features of rocket propulsion systems operating in concert with airbreathing engine cycles. Performance evaluation of these types of engines, which are intended to operate from static sea level take-off to supersonic cruise or accerlerate to orbit, requires ground test capabilities which integrate rocket component testing with airbreathing engine testing. A combined cycle engine test facility has been constructed in the General Applied Science Laboratories, Inc. (GASL) Aeropropulsion Test Laboratory to meet this requirement. The facility was designed to support the development of an innovative combined cycle engine concept which features a rocket based ramjet combustor. The test requirements included the ability ...

1995-09-01

222

Dispersant Effectiveness Of Heavy Fuel Oils Using The Baffled Flask Test  

Science.gov (United States)

Dispersants have been widely used as a primary response measure for marine oil spills around the world. Recently, the U.S. Environmental Protection Agency (EPA) developed an improved laboratory dispersant testing protocol, called the Baffled Flask Test (BFT). The BFT protocol w...

223

Status report of the 17-M VAWT program  

Energy Technology Data Exchange (ETDEWEB)

This report is directed at the commercial potential of the 17-m, 100 kW Darrieus Vertical Axis Wind Turbine (VAWT) developed under DOE funding by Sandia National laboratories (SNL) and Alcoa Laboratories. Three of the turbines have come on line over the past 14 months and long-term testing is in progress. As the first commercially adapted Darrieus turbines built by DOE, the superior cost, structural integrity, and output characteristics demonstrated by the prototypes appear particularly promising.

1981-01-01

224

Alloy 800 SG tubing: current status and future challenges  

Energy Technology Data Exchange (ETDEWEB)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. The grade of Alloy 800 tubing used for this service has a controlled Ti/C ratio ({>=}12 for CANDU SGs), and this specification is sometimes termed Alloy 800 M or Alloy 800 NG . There have been very few corrosion-related flaws detected in this material in SG service, and, until recently, no incidences of cracking. There has been extensive R and D carried out on Alloy 800 tubing, both in Canada and elsewhere, under a variety of operating conditions, including shutdowns, which show that it has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. These R and D findings are reflected in the in-service experience. It has been shown from the R and D that Alloy 800 is susceptible to corrosion under acidic conditions, in particular those ...

2007-07-01

225

Alloy 800 SG tubing: current status and future challenges  

International Nuclear Information System (INIS)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. The grade of Alloy 800 tubing used for this service has a controlled Ti/C ratio (#>=#12 for CANDU SGs), and this specification is sometimes termed Alloy 800 M or Alloy 800 NG . There have been very few corrosion-related flaws detected in this material in SG service, and, until recently, no incidences of cracking. There has been extensive R and D carried out on Alloy 800 tubing, both in Canada and elsewhere, under a variety of operating conditions, including shutdowns, which show that it has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. These R and D findings are reflected in the in-service experience. It has been shown from the R and D that Alloy 800 is susceptible to corrosion under acidic conditions, in particular those that ...

2007-08-19

226

Sulphur petroleum coke as a highly effective reducing agent in the production of barite salts  

Science.gov (United States)

Describes laboratory and industrial tests on the use of lowasash sulphurous petroleum coke during reduction of barite. Shows the potential of substituting blast furnace coke with petroleum/coke fines in this process.

1980-01-01

227

Mycolic Acid Analysis by High-Performance Liquid Chromatography for Identification of Mycobacterium Species  

UK PubMed Central (United Kingdom)

Mycobacterium tuberculosis is the etiologic agent of tuberculosis and can be accurately detected by laboratories using commercial genetic tests. Nontuberculosis mycobacteria (NTM) causing other mycobacterioses...Full Text Available

2001-10-01

228

Granite Countertops and Radiation | Radiation Protection | US EPA  

Wastenet

... Top of page Testing Radiation coming from granite countertops results from natural radioactive material in the granite. Identifying the presence and concentration of radioactive elements in granite requires expensive and sophisticated portable instruments or laboratory equipment. These instruments and equipment require proper calibration, and interpretation of ...

229

FLOCCULATION-FLOTATION AIDS FOR TREATMENT OF COMBINED SEWER OVERFLOWS  

Science.gov (United States)

The objectives of this study were to investigate the flocculation/flotation characteristics of combined sewer overflow through laboratory and field testing. The concept involves the introduction of chemicals and buoyant flotation aids into the overflow and the subsequent cofloccu...

230

Durability of stabilized flue gas desulfurization sludge.  

Science.gov (United States)

The effects of freeze-thaw cycling on the strength and durability of samples of compacted, stabilized, wet flue gas desulfurization (FGD) by-products are reported. The results of laboratory tests show a clear relationship between higher water contents and...

1995-01-01

231

Developmental toxicity and structure/activity correlates of glycols and glycol ethers.  

UK PubMed Central (United Kingdom)

In recent years, the National Toxicology Program (NTP) has selected numerous glycol ethers for testing in routine laboratory mammals to ascertain the magnitude of their ability to injure the conceptus....Full Text Available

1984-08-01

232

Camouflage Printing of Nomex Summer Flying Coveralls.  

Science.gov (United States)

An investigation was carried out to determine the effectiveness of Nomex summer flying coveralls printed with a camouflage pattern as compared with the standard plain olive green coveralls. Laboratory tests indicated that camouflage printing of staple Nom...

1966-01-01

233

Automation in urinalysis: evaluation of three urine test strip analysers  

UK PubMed Central (United Kingdom)

A clinical laboratory evaluation was conducted on the Clinitek Auto 2000, the Super Aution Analyzer and the Urotron RL9 for the determination of glucose, protein, pH, blood, ketone-bodies and bilirubin....Full Text Available

1988-01-01

234

Guide to good practices for the development of test items  

Energy Technology Data Exchange (ETDEWEB)

While the methodology used in developing test items can vary significantly, to ensure quality examinations, test items should be developed systematically. Test design and development is discussed in the DOE Guide to Good Practices for Design, Development, and Implementation of Examinations. This guide is intended to be a supplement by providing more detailed guidance on the development of specific test items. This guide addresses the development of written examination test items primarily. However, many of the concepts also apply to oral examinations, both in the classroom and on the job. This guide is intended to be used as guidance for the classroom and laboratory instructor or curriculum developer responsible for the construction of individual test items. This document focuses on written test items, but includes ...

1997-01-01

235

The influence of active screen plasma nitriding parameters on corrosion behavior of a low-alloy steel  

Energy Technology Data Exchange (ETDEWEB)

This work presents a comparative study of low-alloy steel nitriding for different possible techniques. Active screen plasma nitriding (ASPN) is a successful surface modification method that has many advantages over the conventional DC plasma nitriding (CPN). The corrosion behavior of 30CrNiMo8 low-alloy steel has been examined using anodic polarization tests in 3.5% NaCl solution under varying conditions of ASPN and CPN processes. The process variables included active screen setup parameters, treatment temperature (550 and 580 deg. C), gas mixture (25/75 and 75/25 of N{sub 2}/H{sub 2}) and treatment time (5 and 10 h) in 500 Pa pressure. The structure and phases composition of the compound layer was studied by X-ray diffraction (XRD), microhardness tests, optical microscopy and scanning electron microscopy (SEM). It was observed that ASPN treated samples surface enhanced corrosion resistance while the ...

2009-09-18

236

The influence of active screen plasma nitriding parameters on corrosion behavior of a low-alloy steel  

International Nuclear Information System (INIS)

This work presents a comparative study of low-alloy steel nitriding for different possible techniques. Active screen plasma nitriding (ASPN) is a successful surface modification method that has many advantages over the conventional DC plasma nitriding (CPN). The corrosion behavior of 30CrNiMo8 low-alloy steel has been examined using anodic polarization tests in 3.5% NaCl solution under varying conditions of ASPN and CPN processes. The process variables included active screen setup parameters, treatment temperature (550 and 580 deg. C), gas mixture (25/75 and 75/25 of N_2/H_2) and treatment time (5 and 10 h) in 500 Pa pressure. The structure and phases composition of the compound layer was studied by X-ray diffraction (XRD), microhardness tests, optical microscopy and scanning electron microscopy (SEM). It was observed that ASPN treated samples surface enhanced corrosion resistance while the temperature ...

2009-09-18

237

Inhibition of corrosion resistant alloys in hot hydrochloric acid solutions  

Energy Technology Data Exchange (ETDEWEB)

Weight loss measurements were performed in 20% and 28% hydrochloric acid at 90/sup 0/C on carbon steel, 22Cr5Ni duplex stainless steel, and two superaustenitic steels - 27Cr31Ni3Mo and 19Cr25Ni4Mo -, in presence of organic substances used singly or mixed. The organic substances examined were quaternary ammonium salts (1-4-pyridyl)-pyridinium chloride hydrochloride, dodecylpyridiniumchloride, benzyldimethylstearylammonium chloride, and dodecyltrimethylammonium bromide), alkynols (1-octyn-3-ol, propargyl alcohol) and trans-cinnamaldehyde. The synergistic effect of potassium iodide on the inhibitive efficiency of the organic substances was studied. The variations of corrosion rate during the test time (normally six hours) were recorded by means of polarization resistance measurements. Polarization curves were also recorded. The results showed that the corrosion rates of the four steels examined can be reduced to less than 1 ...

1988-12-01

238

Influence of some processing factors on susceptibility to caustic stress corrosion cracking of modified alloy 800  

International Nuclear Information System (INIS)

The influence of some processing factors such as cold work and heat treatment on the susceptibility to caustic stress corrosion cracking (SCC) of modified alloy 800, referred to alloy 800 M, in a boiling solution of 50%NaOH + 0.3%SiO_2+0.3%Na_2S_2O_3 was investigated by means of microstructure examination, tensile test, stress analysis, SCC test of C-rings, Auger electron spectroscopy (AES) and corrosion mode. Cold work led to lengthening of grains, decrease in ductility, increase in strength, residential stress and susceptibility to SCC. With increasing temperature of heat treatment on alloy 800 M after cold work, grains became bigger, ductility increased but strength, residential stress and susceptibility to SCC decreased. SCC cracks on C-ring specimens initiated from pitting and propagated along grain boundaries. AES analysis indicates that the surface films on alloy 800M are enriched in nickel and ...

2005-07-01

239

Development of Stronger and More Reliable Cast Austenitic Stainless Steels (H-Series) Based on Scientific Design Methodology  

Energy Technology Data Exchange (ETDEWEB)

The goal of this program was to increase the high-temperature strength of the H-Series of cast austenitic stainless steels by 50% and upper use temperature by 86 to 140 F (30 to 60 C). Meeting this goal is expected to result in energy savings of 38 trillion Btu/year by 2020 and energy cost savings of $185 million/year. The higher strength H-Series of cast stainless steels (HK and HP type) have applications for the production of ethylene in the chemical industry, for radiant burner tubes and transfer rolls for secondary processing of steel in the steel industry, and for many applications in the heat-treating industry. The project was led by Duraloy Technologies, Inc. with research participation by the Oak Ridge National Laboratory (ORNL) and industrial participation by a diverse group of companies. Energy Industries of Ohio (EIO) was also a partner in this project. Each team partner had well-defined roles. Duraloy Technologies led the team by identifying the base ...

2006-04-15

240

Reservoir technology research at the Idaho National Engineering Laboratory  

Energy Technology Data Exchange (ETDEWEB)

The Idaho National Engineering Laboratory (INEL) has been conducting geothermal reservoir research and testing sponsored by the US Department of Energy (DOE) since 1983. The INEL research program is primarily aimed at the development of reservoir engineering techniques for fractured geothermal reservoirs. Numerical methods have been developed which allow the simulation of fluid flow and heat transfer in complex fractured reservoirs. Sensitivity studies have illustrated the importance of incorporating the influence of fractures in reservoir simulations. Related efforts include fracture characterization, geochemical reaction kinetics and field testing.

1987-01-01

241

Final report on the project entitled: Highly Preheated Combustion Air System with/without Oxygen Enrichment for Metal Processing Furnaces  

Energy Technology Data Exchange (ETDEWEB)

This work develops and demonstrates a laboratory-scale high temperature natural gas furnace that can operate with/without oxygen enrichment to significantly improve energy efficiency and reduce emissions. The laboratory-scale is 5ft in diameter & 8ft tall. This furnace was constructed and tested. This report demonstrates the efficiency and pollutant prevention capabilities of this test furnace. The project also developed optical detection technology to control the furnace output.

2007-02-16

242

Analytical laboratory and mobile sampling platform. Progress report, October 1, 1994--December 31, 1994  

Energy Technology Data Exchange (ETDEWEB)

This paper is a quarterly report describing the use of a new soil gas collection device which allows the collection of soil gas in the field for later analysis in the laboratory. It describes the installation of this sampling device and the procedure for setting the probe, extraction of soil gas beneath the surface, and sealing of the soil gas for transport. The sites used for initial testing was the top of Yucca Mountain and Crystal Spring in Ash Meadows National Wildlife Refuge. The results from this initial test showed no volatile matter present in the soil at these locations.

1994-12-31

243

Influence of titanium addition on pitting, crevice and intergranular corrosion resistance of type 316 austenitic stainless steel  

International Nuclear Information System (INIS)

Pitting crevice and intergranular corrosion resistances of titanium-modified low-carbon austenitic stainless steel with a nominal composition of 15% Cr, 15% Ni, 0.24% Ti and 2.5% Mo were found superior to conventional type 316 SS. Potentiodynamic anodic polarization studies in a neutral chloride medium (0.5M NaCl solution) and the immersion studies in boiling solution containing (by wt%) 11% H_2SO_4 + 3% HCl + 1% CuCl_2 + 1% FeCl_3 for 24 h showed higher critical pitting and crevice potentials and lower corrosion rate values respectively. The elemental composition across the pit sites was also determined by EPMA analysis. Sensitization studies carried out by following ASTM A262 practices A and E and electrochemical potentiokinetic reactivation (EPR) tests on this alloy heat treated at 923 K for 1 and 50 h showed a better resistance to intergranular corrosion than that for conventional type 316 SS. From ...

244

Effects of irradiation on the microstructural evolution and corrosion resistance of zirconium alloys  

International Nuclear Information System (INIS)

Zircaloy-2 and Zircaloy-4 tubing materials were irradiated with 1 MeV proton at 350 degrees C to doses of 0.01, 0.1, and 1 dpa respectively. Both microstructure examination and nodular corrosion test (500 degrees C, 1500 psi steam) were performed in order to understand the relationship between the microstructural evolution and the corrosion resistance of these alloys under irradiation. Neutron-irradiated Zircaloy-2 specimens which were obtained from a failed BWR fuel rod cladding were also studied. Specimens of three different neutron fluences were investigated; namely, 2.6x10"2"4, 3.2x10"2"5, 3.8x10"2"5, (E_n#>=#1MeV). The results indicated that the higher the irradiation dose the better the nodular corrosion resistance of both Zircaloy-2 and Zircaloy-4. It is concluded that irradiation-induced precipitate dissolution and irradiation-enhanced diffusion may increase the solute concentration in the ...

1991-08-25

245

Corrosion fatigue of magnesium alloys  

Energy Technology Data Exchange (ETDEWEB)

To study the fatigue life of extruded AZ31 (3%Al, 1%Zn, 0.3%Mn, Mg - the rest), AM50 (5%Al, 0.4%Mn, Mg - the rest) and ZK60 (5%Zn, 0.5%Zr, Mg - the rest) Mg alloys in air and NaCl-based solutions, corrosion fatigue tests were carried out using a rotating beam type fatigue machine. For the analysis of the corrosion fatigue behavior of Mg alloys in different environments, fitted N{sub sol}/N{sub air} ratio considered as a relative corrosion fatigue life is used. Here N{sub sol} and N{sub air} are the numbers of cycles to failure in the solution and in air, respectively. An extruded ZK60 alloy shows very high fatigue and corrosion fatigue properties in comparison with other alloys. However, ZK60 shows the lowest values of the relative fatigue life (N{sub sol}/N{sub air} {proportional_to}10{sup -3}-10{sup -2}) compared to that for AM50 and AZ31 alloys (N{sub sol}/N{sub air} ...

2003-07-01

246

Corrosion behaviors of Zn/Al-Mn alloy composite coatings deposited on magnesium alloy AZ31B (Mg-Al-Zn)  

International Nuclear Information System (INIS)

After being pre-plated a zinc layer, an amorphous Al-Mn alloy coating was applied onto the surface of AZ31B magnesium alloy with a bath of molten salts. Then the corrosion performance of the coated magnesium alloy was examined in 3.5% NaCl solution by potentiodynamic polarization and electrochemical impedance spectroscopy (EIS). The results showed that the single Zn layer was active in the test solution with a high corrosion rate while the Al-Mn alloy coating could effectively protect AZ31B magnesium alloy from corrosion in the solution. The high corrosion resistance of Al-Mn alloy coating was ascribed to an intact and stable passive film formed on the coating. The performances of the passive film on Al-Mn alloy were further investigated by Mott-Schottky curve and X-ray photoelectron spectroscopy (XPS) analysis. It was confirmed that the passive film exhibited n-type semiconducting ...

2009-12-30

247

Stability and disturbance of large dc superconducting magnets  

Energy Technology Data Exchange (ETDEWEB)

This paper addresses the stability aspects of several successful dc superconducting magnets such as large bubble chamber magnets, and magnets for the Mirror Fusion Test Facility and MHD Research Facility. Specifically, it will cover Argonne National Laboratory 12-Foot Bubble Chamber magnets, the 15-foot Bubble Chamber magnets at Fermi National Laboratory, the MFTF-B Magnet System at Lawrence Livermore National Laboratory, the U-25B Bypass MHD Magnet, and the CFFF Superconducting MHD magnet built by Argonne National Laboratory. All of these magnets are cooled in pool-boiling mode. Magnet design is briefly reviewed. Discussed in detail are the adopted stability critera, analyses of stability and disturbance, stability simulation, and the final results of magnet performance and the observed coil disturbances.

1981-11-11

248

Laboratory for characterization of spent nuclear fuel and high/medium level radioactive waste. Experimental results and performances  

International Nuclear Information System (INIS)

During the phases of separation, treatment, conditioning and storage of radioactive waste, destructive and nondestructive methods for their characterization are needed. In order to satisfy this necessity, in the frame of the National Program of Research and Development, the 'Laboratory for characterization of spent nuclear fuel and high/medium level radioactive waste- LABORAD' was created. The purpose of the project was to accredit the analysis methods available in the laboratory, and also to develop new methods for the characterization of the radioactive waste. A special attention was paid to the high-level radioactive waste and spent nuclear fuel characterization that require special facilities for handling. These facilities (e.g. hot cells, remote handlers, transport container) are already available in our institute. Experimental results and performances obtained during validation of the methods are presented in this paper. The ...

2009-05-27

249

Effects of a chelating resin on metal bioavailability and toxicity to estuarine invertebrates: Divergent results of field and laboratory tests  

International Nuclear Information System (INIS)

Benthic invertebrates can uptake metals through diffusion of free ion solutes, or ingestion of sediment-bound forms. This study investigated the efficacy of the metal chelating resin SIR 300TM in adsorbing porewater metals and isolating pathways of metal exposure. A field experiment (Botany Bay, Sydney, Australia) and a laboratory toxicity test each manipulated the availability of porewater metals within contaminated and uncontaminated sediments. It was predicted that within contaminated sediments, the resin would adsorb porewater metals and reduce toxicity to invertebrates, but in uncontaminated sediments, the resin would not significantly affect these variables. Whereas in the laboratory, the resin produced the predicted results, in the field the resin increased porewater metal concentrations of contaminated sediments for at least 34 days and decreased abundances of four macroinvertebrate groups, and richness in all ...

2010-05-01

250

Structural steels with improved atmospheric corrosion resistance  

CERN Document Server

Structural steels with improved atmospheric corrosion resistance

2003-01-01

251

Corrosion Protection of special steels and alloys  

International Science & Technology Center (ISTC)

Development of the Corrosion Protection Technology for Special Steels and Alloys

252

Hideout return testing from support crevices  

International Nuclear Information System (INIS)

The objectives of the project were to develop operational techniques for promoting contaminant hideout return from tube support crevices and to identify the effect of chemical inhibitor application on corrodent transport. The implementation of routine procedures for promoting the return of sequestered corrodents could retard the progression of denting or other corrosion processes and improve steam generator availability. Tests also quantified the effect of inhibitor application on crevice hideout and hideout return processes, with the intention of developing a better understanding of the inhibition mechanism. By carefully monitoring the hideout and hideout return inventories, the program also has provided the opportunity to study steam generator concentration processes in general.

1985-03-01

253

Development of a Stable-Beta Titanium Alloy, Quarterly Report Number 10, October 1 - December 31, 1964.  

Science.gov (United States)

Evaluation of ageable beta alloys Ti-17V-2Fe-2Co-3Al, Ti-17V-7.5Co-3A1 and Ti-8Mo-8V-5Co-3Al continued with room and elevated temperature smooth and notched tensile tests, creep stability, oxidation and stress-corrosion tests. Ti-17V-7.5Co-3Al aged more r...

1964-01-01

254

A 34-meter VAWT (Vertical Axis Wind Turbine) point design  

Science.gov (United States)

The Wind Energy Division at Sandia National Laboratories recently completed a point design based on the 34-m Vertical Axis Wind Turbine (VAWT) Test Bed. The 34-m Test Bed research machine incorporates several innovations that improve Darrieus technology, including increased energy production, over previous machines. The point design differs minimally from the Test Bed; but by removing research-related items, its estimated cost is substantially reduced. The point design is a first step towards a Test-Bed-based commercial machine that would be competitive with conventional sources of power in the mid-1990s.

1991-01-01

255

Year 2000 assessment report, Los Alamos National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this report is to advise managers on the status of Year 2000 readiness at the Laboratory and provide a summary of critical issues to be addressed in order to ensure that the Year 2000 date rollover will not disrupt Laboratory Operations. The Laboratory`s Year 2000 council members are in the first phase of Year 2000 plans: gathering data and assessing the status of their divisions or programs. This first snapshot of the Laboratory Year 2000 readiness assessment is expected to grow and change over time as more refined assessments, plans, and schedules are developed and as more information becomes available. Here are findings to date: (1) Embedded systems` status not known. (2) Preliminary cost estimates for Year 2000 repairs, testing, and implementation are estimated to be at least $5.9 million, not including embedded systems. (3) The Laboratory is ...

1998-04-21

256

Corrosion 2003. Conference papers on CD-ROM  

Energy Technology Data Exchange (ETDEWEB)

Papers are presented under 38 symposia. Subjects included reinforced concrete, protective coatings and linings, cathodic/anodic protection, chemical cleaning of boilers, managing corrosion with plastics, water treatment, HRSG boiler tube failure analysis, corrosion in oil and gas production, corrosion in petroleum refining and gas, processing, pipelines and tanks, high temperature materials, chemical process industry, aerospace equipment, materials technology developments for incinerators and waste fuel-fired processors, materials and corrosion in fossil-fuels conversion and combustion, corrosion in nuclear systems, marine corrosion, building systems, corrosion mechanisms, corrosion inhibitors and corrosion monitoring and measurement.

2003-07-01

257

Tests for the diagnosis of Clostridium difficile infection: the next generation.  

Science.gov (United States)

Clostridium difficile (C. difficile) causes 25-30% of cases of antibiotic associated diarrhea and most cases of pseudomembranous colitis. Patients presenting with diarrhea after hospitalization for 3 or more days should be tested for C. difficile. There are many options available for testing, each of which has inherent advantages and disadvantages. Most laboratories perform toxin testing using an enzyme immunoassay method. In general these tests have sensitivities ranging from 60 to 70% and specificities of 98%. When using these methods, symptomatic patients with negative tests should be tested by another more sensitive method. Until recently, cell culture cytotoxicity neutralization assays (CCNAs) were considered the gold standard in the U.S. A two-step algorithm using an EIA for glutamate dehydrogenase detection followed by ...

2011-03-03

258

The influence of furnace geometry and wall materials on the combustion process and the prediction of problem areas in waste incinerators  

Energy Technology Data Exchange (ETDEWEB)

Based on the CFD-code FLUENT trademark, theoretical studies were conducted of the influences of incineration chamber geometry (direct, countercurrent and center flow) on the combustion process. The boundary conditions, e.g., the thermal input and the waste grate, were kept constant. Close attention was paid to the distribution of flow, spe-cies, and temperatures. In addition, the influence of a dis-placement body at the end of the combustion chamber was tested. The variation of different wall materials and the prediction of problem areas concerning corrosion, slagging, and contamination completed the studies. Close to the chamber walls, high CO-concentrations may indi-cate corrosion; particle flow may indicate where contami-nation, slagging or erosion could occur. (orig.)

2001-01-01

259

Structure and properties of stainless steels after plasma immersion ion implantation and plasma nitriding; Struktur und Eigenschaften nichtrostender Staehle nach einer Plasmaimmersionsionenimplantation und einer Plasmanitrierung  

Energy Technology Data Exchange (ETDEWEB)

Stainless steels can be nitrided at temperatures {<=}400 C to increase their hardness and wear resistance without a decreasing of their excellent corrosion resistance. Structure and properties of the surface layers produced by plasma nitriding and plasma immersion ion implantation in this temperature range were tested. There are negligible differences in the structure of the produced surface layers in spite of different interaction principles of the used technologies. However there are clear differences between the case of different steels. The case of ferritic chromium steels mainly consists of {epsilon}-nitride. Whereas the cases of austenitic and ferritic austenitic steels are characterized by expanded austenite. The corrosion resistance of the steels is reduced by nitriding only, if evident CrN-formation occurs. (orig.) 11 refs.

1999-08-01

260

Plasma nitrided titanium as a bipolar plate for proton exchange membrane fuel cell  

Energy Technology Data Exchange (ETDEWEB)

Plasma nitriding was applied to improve the surface performance of titanium bipolar plate. XRD and SEM results showed a titanium nitride layer was formed after nitridation. In comparison with pure titanium, the interfacial contact resistance of plasma nitrided titanium was reduced to some extent by the nitridation treatment. However, high corrosion current was observed under electrochemical tests in 0.5 M H{sub 2}SO{sub 4} + 5 ppm HF. Both the electrical conductivity and corrosion resistance of the surface of plasma nitriding titanium did not reach the level of graphite. Some more improvements are expected in the plasma nitriding process or another surface modification on pure titanium. (author)

2009-02-15

261

In situ composite coating of titania-hydroxyapatite on titanium substrate by micro-arc oxidation coupled with electrophoretic deposition processing  

British Library Electronic Table of Contents (United Kingdom)

In situ composite coating of hydroxyapatite (HA)/TiO2 were produced on titanium (Ti) substrate by micro-arc oxidation coupled with electrophoretic deposition (MAO&EPD) technique with different concentrations of HA particles in the 0.2M NaOH electrolyte solution. The surface morphology and chemical composition of the hybrid coating were effected by HA concentration. The amount of HA particles incorporated into coating layer increased with increasing HA concentration used in the electrolyte solution. The corrosion behavior of the coating layer in simulated body fluids (SBF) was evaluated using a potentiodynamic polarization test. The corrosion resistance of the coated sample was increased compared to the untreated Ti sample. The in vitro bioactivity assessment showed that the MAO&EPD treated...

2011-01-01

262

Degradation of the corrosion resistance of anodic oxide films through immersion in the anodising electrolyte  

Energy Technology Data Exchange (ETDEWEB)

The deterioration of AA2024, AA6061 and AA7475 anodised in an environmentally-compliant tartaric acid/sulphuric acid electrolyte has been examined as a function of the immersion time in the electrolyte after termination of anodising. By transmission electron microscopy and scanning electron microscopy, degradation of the porous oxide film was qualitatively observed on AA2024. Electrochemical impedance spectroscopy revealed that AA2024 and AA7075 were more sensitive to prolonged immersion in the anodising electrolyte compared with AA6061, due to increased barrier layer thinning rates and increased susceptibility to localized corrosion. Salt spray tests confirmed the previous, indicating decay of anticorrosion performance for AA2024 and AA7075.

2010-07-15

263

Alteration of leached glass surface  

Energy Technology Data Exchange (ETDEWEB)

The leached glass is subject to leachant attack and results in surface layer alteration which greatly affects the corrosion progress of glass forms. This work studied the composition change, precipitation, pitting corrosion as well as surface layer break and spallation of the leached glass forms. 6 conclusions can be made: 1. The extent of surface layer alteration is related to many factors such as temperature, pH, leachant chemistry, flow rate and leach duration, etc. 2. The alkali element Na is seriously depleted and the elements like U.Ti,Fe, Ca and Mg are enriched in the surface layer. The influence of media has such order: Fe{sub 2}O{sub 3} > Na-bentonite > Zeolite. 3. The precipitate formed in leach test for 56 days at 90 {infinity}C is mostly amorphous, but after 91 days has crystallized. There is K - Ca - Al - Si crystal,the amount of Al, K and Si is increasing, but the amount of Ca is decreasing along ...

1997-07-01

264

Laboratory ageing of transformer oils  

Energy Technology Data Exchange (ETDEWEB)

The insulating oil used in a transformer is a critical component, as its service life is typically 20 years with possibly little or no maintenance. Partial discharges (PD), thermal overloads and static discharges continually subject the oil to chemical deterioration during its operating life. To ensure equipment reliability during service, it is important that the initial quality of the new insulating oil should meet the required acceptance specifications and preferably be pre-tested before use. Accelerated aging tests have been devised to determine the life expectancy of oil in service by using forced air or oxygen flow into the oil, the presence of a copper catalyst, and at elevated temperatures. The more important standards relating to transformer application are discussed and highlights of the more important aspects of the oxidation chemistry of hydrocarbons are included. The ultimate aim of the project is the formulation of better standard ...

1996-04-01

265

Advanced Fuel/Cladding Testing Capabilities in the ORNL High Flux Isotope Reactor  

Energy Technology Data Exchange (ETDEWEB)

The ability to test advanced fuels and cladding materials under reactor operating conditions in the United States is limited. The Oak Ridge National Laboratory (ORNL) High Flux Isotope Reactor (HFIR) and the newly expanded post-irradiation examination (PIE) capability at the ORNL Irradiated Fuels Examination Laboratory provide unique support for this type of advanced fuel/cladding development effort. The wide breadth of ORNL's fuels and materials research divisions provides all the necessary fuel development capabilities in one location. At ORNL, facilities are available from test fuel fabrication, to irradiation in HFIR under either thermal or fast reactor conditions, to a complete suite of PIEs, and to final product disposal. There are very few locations in the world where this full range of capabilities exists. New testing capabilities at HFIR have been developed that ...

2009-09-01

266

Tribological and corrosion testing of surface engineered surgical grade CoCrMo alloy  

British Library Electronic Table of Contents (United Kingdom)

One of the main causes of hip prostheses failure is the premature wear of its components. Wear of metal-on-metal joints is a concern due to the toxicity and biological reaction of wear debris and metallic corrosion. The main aim of the present study was to investigate the tribological and corrosion behavior of surface engineering CoCrMo alloy. Different surface conditions were obtained on surgical grade wrought CoCrMo alloy: plasma nitrided (520^oC by 7h at gas mixture of 10% N2+90% H2), PVD coated (monolayer CrN and multilayer (TiN/CrN)x3) and modified using duplex surface engineering technology (a combination of the two previous approaches: plasma nitriding followed by plasma assisted PVD). Surfaces were characterized using scanning electron microscopy, nanoindentation, AFM and scratch t...

2011-01-01

267

Stress corrosion cracking of type 304L stainless steel core shroud welds.  

Energy Technology Data Exchange (ETDEWEB)

Microstructural analyses by advanced metallographic techniques were conducted on mockup welds and a cracked BWR core shroud weld fabricated from Type 304L stainless steel. heat-affected zones of the shroud weld and mockup shielded-metal-arc welds were free of grain-boundary carbide, martensite, delta ferrite, or Cr depletion near grain boundaries. However, as a result of exposure to welding fumes, the heat-affected zones of the welds were significantly contaminated by fluorine and oxygen which migrate to grain boundaries. Significant oxygen contamination promotes fluorine contamination and suppresses classical thermal sensitization, even in Type 304 steels. Results of slow-strain-rate tensile tests indicate that fluorine exacerbates the susceptibility of irradiated steels to intergranular stress corrosion cracking. These observations, combined with previous reports on the strong influence of weld flux, indicate that oxygen and fluorine ...

1999-10-26

268

Steam-generator dilute chemical-cleaning program. Steam-generator chemical-cleaning project. Annual report, program start through 1980  

International Nuclear Information System (INIS)

Vertical U-tube steam generators in Pressurized Water Reactors (PWRs) operating an All Volatile Treatment (AVT) secondary chemistry have experienced corrosion problems, particularly denting and sludges. The studies reported evaluate the feasibility of using a low-concentration (0.5 wt%) chemical cleaning process to remove corrosion product deposits from steam generator surfaces and magnetite from tube-to-support plate crevices of PWR steam generators. The process potentially may be applied at schedule intervals, such as during normal refueling outages, to maintain a steam generator in clean operating condition. This report describes the results of testing to evaluate the effectiveness of several chelant acids for dissolving steam generator sludges and crevice magnetite. Corrosion of carbon steel by the chelant acids and the effects of various inhibitors are evaluated. The effectiveness of ion-exchange ...

269

Interactions between creep and corrosion in Alloy 800  

Energy Technology Data Exchange (ETDEWEB)

Metallic components within or immediately adjacent to gasifiers, such as gas distributors, thermowells, transfer lines, and cyclones, are subjected to severe of temperature, pressure, and hostile multicomponent gas environments. Metallic heat exchangers/waste-heat boilers resistant to sulfidation, corrosion. and erosion in low- and medium-Btu gas environments are essential components in large-scale gasification schemes, in both dry ash and slogging type gasifiers. Components, in general. must be resistant to corrosion, erosion, and high-temperature creep. A substantial data base is needed on the mechanical properties of materials exposed to complex gas environments to provide a more viable basis for establishing long-term reliability of components. This work examines high-temperature creep of Alloy 800, a high-chromium alloy widely used in coal conversion systems, after exposure to oxygen and oxygen/sulfur mixed-gas environments over a wide ...

1994-04-01

270

Inductively coupled plasma nitriding of chromium electroplated AISI 316L stainless steel for PEMFC bipolar plate  

Energy Technology Data Exchange (ETDEWEB)

Chromium electroplated AISI 316L stainless steel was nitrided using inductively coupled plasma (ICP) for application in the bipolar plate of a polymer electrolyte membrane fuel cell (PEMFC). A continuous and thin chromium nitride layer was formed at the surface of the samples after ICP nitriding for 2 h at 400 C. The interfacial contact resistance (ICR) and corrosion resistance in simulated PEMFC operating conditions were higher than the required values, while they varied with the applied dc bias voltage during the nitriding process. The ICR value decreased with an increase in bias voltage. Potentiodynamic polarization measurements showed that all of the nitrided samples had excellent corrosion resistance with a current density of {proportional_to}10{sup -7} A cm{sup -2} at the cathode. It was also found that the oxygen content at the surface was not increased after the corrosion test. X-ray ...

2009-03-15

271

Effect of halogens and inhibitors on the external stress corrosion cracking of Type 304 austenitic stainless steel  

Energy Technology Data Exchange (ETDEWEB)

The methodology of the drip procedure of the Standard Test Method for Evaluating the Influence of Thermal Insulation on External Stress Corrosion Cracking Tendency of Austenitic Stainless Steel (ASTM C 692-95a) was used to research the effect of halogens and inhibitors on the external stress corrosion cracking (ESCC) of Type 304 stainless steel as it applies to the insulation industry. Simulated insulation extraction solutions were made with pure chemical reagents for the halogens and inhibitors. The results indicated that sodium silicate compounds that were higher in sodium were more effective for preventing chloride-induced ESCC in Type 304 austenitic stainless steel. Potassium silicate was not as effective as sodium silicate. Fluoride, bromide, and iodide may cause ESCC but they were much less active than chloride and could be effectively inhibited by sodium silicate compound. The addition of fluoride ions to the ...

1997-11-01

272

Remedial action plan and site design for stabilization of the inactive uranium mill tailings sites at Rifle, Colorado. Volume 5, Addenda D6--D8 to Appendix D: Final report  

Energy Technology Data Exchange (ETDEWEB)

This volume contains appendices D6 through D8 containing laboratory test data: from MK-F investigation, 1987, Old Rifle and New Rifle sites; on bentonite amended radon barrier material; and from MK-F investigation, 1987, riprap tests.

1990-02-01

273

Off-line and on-line-monitoring of power transformers using the transfer function method  

Energy Technology Data Exchange (ETDEWEB)

The transfer function concept is well known as an additional method to evaluate the impulse test of power transformers in the test laboratory. Another application for the transfer function method is monitoring of transformers in service. Thereby, Off-line and On-line monitoring can be realized. Both kinds of monitoring are demonstrated with on-site measurements on a power transformer in service.

1996-12-31

274

Investigation of GOSIP technology at ANL  

Energy Technology Data Exchange (ETDEWEB)

This document describes testing of OSI products conducted at Argonne National Laboratory. Sun, IBM, and Clsco hardware platforms were used. Various software packages that implement file transfer and gateway applications were evaluated. The OSI model and GOSIP compliance are briefly discussed. Technical details on OSI addressing and routing are presented. The relationship of this testing to other OSI activities at Argonne and to activities of the national networking community is discussed. Mention is also made of the relationship of DECnet Phase V transition issues.

1992-01-01

275

Implementation and laboratory test results for a fuzzy logic based self-tuned power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the implementations of a fuzzy logic based self-tuned controller to improve the stability of electric power systems. The stabilizing signal is computed using the standard fuzzy membership function depending on the speed/acceleration state of the generator in the phase plane. The performance of the proposed stabilizer is demonstrated by practical implementation using a digital signal processor mounted on a PC-AT. Results of the experimental tests on a physical model of a power system are presented.

1993-06-01

276

Fuel ignition by high voltage capacitive discharges  

Energy Technology Data Exchange (ETDEWEB)

The study examined the possibility for fuel ignition by spark discharge caused by induction effects under high voltage transmission lines. Theoretical background information on capacitive spark discharges and fuel ignition processes is given. Laboratory experiments were conducted to test the dependence of fuel ignition on three parameters: impedance in discharge path, multiple discharges, and larger electrode shapes. The results of these tests are discussed in terms of fuel ignition possibilities under high voltage transmission lines.

1983-03-01

277

Annual report 1993-1994  

Energy Technology Data Exchange (ETDEWEB)

The Atlantic Wind Test Site was established in 1980 as a laboratory to facilitate the evaluation and demonstration of wind energy systems and equipment. This annual report describes its organization and management, facilities, major projects, and the outlook for the future. Major projects include wind diesel; AWTS-IREQ collaboration; remote community data acquisition; lagerwey test program; Alaska Energy Authority Project; public education; Atlantic Orient Corporation 15/50 Project; and the soft VAWT project.

1994-12-31

278

Soil electrical resistivity -- An essential parameter for power plant design  

Energy Technology Data Exchange (ETDEWEB)

Soil electrical resistivity is perhaps the only soil parameter that is used by geologists and geotechnical engineers to explore the subsurface characteristics at a power plant site and also used by civil and electrical engineers as input to their design. A properly designed and executed field electrical resistivity survey is one method of examining the subsurface profile. The same program can provide information about the corrosion potential of the soil that can play a major role in determining the protection needed for buried steel piping and pile foundations. At the same time, the soil conductivity interpreted from the results of the resistivity testing is an integral part of the design of the electrical grounding system for the plant. This paper describes soil electrical resistivity, test procedures to estimate resistivity values, and how these values can best be used to obtain the parameters required for successful ...

1996-11-01

279

High energy photon-photon collisions  

International Nuclear Information System (INIS)

The collisions of high energy photons produced at an electron-positron collider provide a comprehensive laboratory for testing QCD, electroweak interactions, and extensions of the standard model. The luminosity and energy of the colliding photons produced by backscattering laser beams is expected to be comparable to that of the primary e"+e"- collisions. In this overview, we shall focus on tests of electroweak theory in photon-photon annihilation, particularly #gamma##gamma##->#W"+W"-, #gamma##gamma##->#Higgs bosons, and higher-order loop processes, such as #gamma##gamma##->##gamma##gamma#, Z#gamma# and ZZ. Since each photon can be resolved into a W"+W"- pair, high energy photon-photon collisions can also provide a remarkably background-free laboratory for studying WW collisions and annihilation. We also review high energy #gamma##gamma# tests of quantum chromodynamics, ...

280

Reversed light-dark cycle and cage enrichment effects on ethanol-induced deficits in motor coordination assessed in inbred mouse strains with a compact battery of refined tests  

British Library Electronic Table of Contents (United Kingdom)

The laboratory environment existing outside the test situation itself can have a substantial influence on results of some behavioral tests with mice, and the extent of these influences sometimes depends on genotype. For alcohol research, the principal issue is whether genotype-related ethanol effects will themselves be altered by common variations in the lab environment or instead will be essentially the same across a wide range of lab environments. Data from 20 inbred strains were used to reduce an original battery of seven tests of alcohol intoxication to a compact battery of four tests: the balance beam and grip strength with a 1.25g/kg ethanol dose and the accelerating rotarod and open-field activation tests with 1.75g/kg. The abbreviated battery was then used to study eight inbred str...

2011-01-01

281

FFTF operating experience, 1982-1984  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a 400 Mwt sodium-cooled fast reactor operating at the Hanford Engineering Development Laboratory, Richland, Washington, to conduct fuels and materials testing in support of the US Liquid Metal Fast Breeder Reactor (LMFBR) program. Startup and initial power testing included a comprehensive series of nonnuclear and nuclear tests to verify the thermal, hydraulic, and neutronic characteristics of the plant. A specially designed series of natural circulation tests were then performed to demonstrate the inherent safety features of the plant. Early in 1982, the FFTF began its first 100-day irradiation cycle. Since that time the plant has operated very well, achieving a cycle capacity factor of 94% in the most recent irradiation cycle. Seventy-five specific test assemblies and 25,000 individual fuel pins have ...

1984-04-09

282

Applicability of structural wall test results to seismic design of nuclear facilities  

International Nuclear Information System (INIS)

A review of tests on earthquake-resistant reinforced concrete structural walls is presented. Laboratory tests of isolated walls and construction joints are discussed. Where appropriate, design recommendations are given. The review indicates only few experimental data are available for short walls which are directly applicable to nuclear power plant design. In particular, tests of short rectangular walls subjected to load reversals are needed. Tests are also needed to determine the damping and frequency characteristics of cracked short walls. Analytical and experimental results should be correlated so that the hysteretic response observed in tests can be realistically related to the analytical response 'demand' of nuclear power plant structures. (Auth.).

283

Laboratory development of +- 600 kVdc pipe type cable systems  

Energy Technology Data Exchange (ETDEWEB)

In 1976, the US Department of Energy and New York State - ERDA granted a contract for the development of a +-600 kV dc underground transmission cable system looking to inevitable future requirements in the US for economic, high-capacity, long-distance underground transmission linking remote generating stations to metropolitan load centers. This project was comprehensive and dealt with three separate system components, i.e., cable, splice, and terminals. In each instance, for each component, development required an intensive R and D effort, focused on the following categories: insulating materials, model testing, design of full-scale prototype, manufacturer of prototype, and laboratory development testing. Insulating papers and oils were selected, and model studies performed, for both self-contained type and pipe type oil-filled cables. However, only the pipe cable design was finally designated for full-size cable ...

1982-07-01

284

Effect of water chemistry improvement on flow accelerated corrosion in light-water nuclear reactor  

International Nuclear Information System (INIS)

Flow Accelerated Corrosion (FAC) of Carbon Steel (CS) piping has been one of main issues in Light-Water Nuclear Reactor (LWRs). Wall thinning of CS piping due to FAC increases potential risk of pipe rupture and cost for inspection and replacement of damaged pipes. In particular, corrosion products generated by FAC of CS piping brought steam generator (SG) tube corrosion and degradation of thermal performance, when it intruded and accumulated in secondary side of PWR. To preserve SG integrity by suppressing the corrosion of CS, High-AVT chemistry (Feedwater pH9.8#+-#0.2) has been adopted to Tsuruga-2 (1160 MWe PWR, commercial operation in 1987) in July 2005 instead of conventional Low-AVT chemistry (Feedwater pH 9.3). By the High-AVT adoption, the accumulation rate of iron in SG was reduced to one-quarter of that under conventional Low-AVT. As a result, a tendency to degradation of the SG thermal ...

2009-10-01

285

Study of the action of a phosphonate additive on steel scale deposit and corrosion in the hydrodynamic conditions of a channel flow cell; Etude de l'action d'un additif phosphone sur l'entartrage et sur la corrosion de l'acier dans les conditions hydrodynamiques d'une cellule a canal  

Energy Technology Data Exchange (ETDEWEB)

In cooling systems, an improved control of scale deposit and corrosion processes is a major challenge and an realistic evaluation tool for water treatments is of the utmost economic importance. In this study, a channel flow cell was used to allow in-situ electrochemical measurements in well defined electrolyte tube flowing conditions. An expression of the mass transfer towards the electrode was established where the diffusion-limited current is a function of Re{sup 1/3} in the laminar regime and was verified experimentally using the redox couples Fe[CN]{sub 6}{sup 4-}/ Fe[CN]{sub 6}{sup 3-} and O{sub 2}/OH{sup -}. This hydrodynamically controlled experimental device was developed to investigate scale deposit processes and to evaluate scale inhibitor efficiency using a electrochemical quartz crystal microbalance. Experiments were performed on three different waters, at various flow rates and temperatures. The efficiency of a well known phosphonate (HEDP) was ...

2000-10-17

286

Plasma nitriding and plasma nitrocarburizing of electroplated hard chromium to increase the wear and the corrosion properties  

Energy Technology Data Exchange (ETDEWEB)

We have investigated the effect of plasma nitriding and plasma nitrocarburizing on the microstructure and properties of electroplated chromium. Plasma nitriding and plasma nitrocarburizing are applied to 15-100 [mu]m thick electroplated hard chromium coatings to increase both the wear and the corrosion resistance. The properties of the plasma-modified hard chromium layers are characterized by measuring the wear resistance with a Taber wear tester and the corrosion resistance with a salt spray fog test. Cyclic voltammetry is performed in a standard electrochemical cell using a 0.5 M H[sub 2]SO[sub 4] solution acidified to pH 0.3. The compound layer after plasma nitriding consists of CrN and Cr[sub 2]N with a maximum hardness of about 1100 HK[sub 0.01]. After plasma nitrocarburizing, Cr[sub 3]C[sub 2] and Cr[sub 7]C[sub 3] are formed. After plasma nitrocarburizing, the maximum hardness is increased up to 2200 HK[sub 0.01]. ...

1999-02-01

287

Mechanical properties and corrosion behavior of materials exposed to an experimental, atmospheric fluidized-bed combustor  

Energy Technology Data Exchange (ETDEWEB)

A joint materials test program developed by the Institute for Mining and Minerals Research (IMMR) and the Tennessee Valley Authority (TVA) involved the postexposure mechanical properties and corrosion behavior of candidate structural materials in an experimental, atmospheric fluidized-bed combustor (AFBC). This combustor was operated by Accurex Corporation at Research Triangle Park, North Carolina, under the direction of TVA. The materials studied were Type 304, Type 310, and INCOLOY alloy 800 in the form of disc coupons with and without crevice configurations. Type 304 was also used for mechanical property measurements. The alloys were exposed to the combustor environment at about840/sup 0/C for approximately 330 hours. The ranking in terms of decreasing weight loss was: (1) Type 304, (2) Type 310, and (3) INCOLOY alloy 800. The presence of tight crevices did not enhance the corrosion rate. In addition, the ...

1984-06-01

288

Bioactivity and corrosion properties of novel coatings containing strontium by micro-arc oxidation  

International Nuclear Information System (INIS)

Research highlights: The dental implant of titanium could be modified by anodic oxidation. It was found that incorporation of strontium ions into the matrix increase the bone formation. In this study, we try to investigate the effect of corrosion property and bioactivity on coatings containing strontium by anodic oxidation. The results suggest that coatings containing strontium on titanium by anodic oxidation has the potential to show the stability and bioactivity in the clinical use. - Abstract: Pure titanium (Ti) and titanium alloys are considered as bio-inert materials in clinical use. Bioactivity is the ability to induce bone-like apatite on the material surface. The micro-arc oxidation (MAO) technique is an effective method for improving the surface properties of titanium. The aim of this study was to investigate the bioactivity and corrosion behavior of MAO coatings containing strontium, which is beneficial for biological performance. The ...

2010-10-22

289

Advanced distillation curve measurements for corrosive fluids: Application to two crude oils  

Energy Technology Data Exchange (ETDEWEB)

We have recently introduced several important improvements in the measurement of distillation curves for complex fluids. The modifications include a composition-explicit data channel for each distillate fraction (for both qualitative and quantitative analysis) and corrosivity assessment of each distillate fraction. The composition-explicit information is achieved with a new sampling approach that allows precise qualitative as well as quantitative analyses of each fraction, on the fly. We have applied the new method to a variety of fluids, including simple n-alkanes, rocket propellant, gasoline, jet fuels, and a hydrocarbon fluid made corrosive with dissolved hydrogen sulfide. In the current contribution, we present the application of the advanced distillation curve method to two samples of crude oil. A primary motivation behind the work is to precisely measure the distillation curves of these oils using our advanced distillation apparatus; ...

2008-10-15

290

Mixed waste solidification testing on polymer and cement-based waste forms in support of Hanford`s WRAP 2A facility  

Energy Technology Data Exchange (ETDEWEB)

A testing program has been conducted by the Westinghouse Hanford Company to confirm the baseline waste form selection for use in Waste Receiving and Processing (WRAP) Module 2A. WRAP Module 2A will provide treatment required to properly dispose of containerized contact-handled, mixed low-level waste at the US Department of Energy Hanford Site in south-central Washington State. Solidification/stabilization has been chosen as the appropriate treatment for this waste. This work is intended to test cement-based, thermosetting polymer, and thermoplastic polymer solidification media to substantiate the technology approach for WRAP Module 2A. Screening tests were performed using the major chemical constituent of each waste type to measure the gross compatibility with the immobilization media and to determine formulations for more detailed testing. Surrogate materials representing each of the eight waste types ...

1993-10-01

291

Evaluation of selected elastomer O-ring pump seals for service at the Wilsonville, Alabama, Advanced Coal Liquefaction Research and Development Facility. [Ethylenepropylenediene monomer compounds  

Energy Technology Data Exchange (ETDEWEB)

Previous laboratory tests of elastomer O-rings in coal liquefaction solvents conducted at L'Garde, Inc., indicated that certain ethylenepropylenediene monomer (EPDM) compounds provided the best performance when a backup ring was used to limit swelling. Before service testing in a pump at the Wilsonville, Alabama, Advanced Coal Liquefaction Research and Development Facility, tests of six selected elastomers in the appropriate Wilsonville-produced solvent were conducted at Oak Ridge National Laboratory (ORNL). The ORNL tests measured the elastomers' changes in cross section, weight, density, and relative flexibility. Although two perfluoroelastomers showed less degradation of most properties during these tests, it was decided to proceed with service testing of two EPDM elastomers because of their much ...

1986-08-01

292

User's guide to PROTOCOL, a numerical simulator for the dissolution reactions of inorganic solids in aqueous solutions  

Energy Technology Data Exchange (ETDEWEB)

This report provides a user's manual for PROTOCOL, a comprehensive coupled kinetic/equilibrium computer program for analyzing the dissolution reactions of solids with aqueous solutions, specifically applied to the potential corrosion of vitrified nuclear waste by groundwater. The capabilities and available options are summarized as well as instructions for setting up and running problems. Also described in this report and included in the PROTOCOL software package are MASTER, a master file of species thermodynamic data, MANEQL, a preprocessor program and POSTP, a postprocessor. POSTP provides offline plotting using the CRAY-1 DISSPLA 9.0 graphics library. PROTOCOL is operational on the CDC-7600 and CRAY-1 computers at the Lawrence Livermore National Laboratory. 7 references, 10 figures, 2 tables.

1984-10-01

293

Failure analyses and weld repair of boiler feed water pumps  

Energy Technology Data Exchange (ETDEWEB)

During a regular inspection of the Boiler Auxiliaries at one of the Dutch Electricity Production Companies serious cracks were found in the cover and casings of the feed water circulation pumps in two units after 108.000 and 122.000 hours of boiler operation. Kema Laboratories carried out Failure analyses on boat samples at the cracked areas. Corrosion fatigue cracking was found on the inner side of the GS-24CrNiMo325 casing. Shop Weld repairs were carried out using a newly developed mechanized Plasma Welding Technique. The repaired feed water circulation pumps showed no problems alter several years of operation. The costs of repair were substantially lower than the costs of replacement. (orig.) 3 refs.

1998-12-31

294

Anodic corrosion protection of sulphuric acid plants with regard to the recovery of heat  

Energy Technology Data Exchange (ETDEWEB)

Anodic protection makes it possible to keep materials which can be passivated in a 'passive' state or to bring them into this state, even in unfavourable conditions. With sulphuric acid concentrations of 93-99% this method permits the use of inexpensive, stainless austenitic steels, e.g. 1.4541 and 1.4591, at temperatures of up to 160/sup 0/C. The temperature range from 120/sup 0/C, in particular, is suitable for heat recovery. Anodic protection by the APR-system provides safe and low-cost protection for air coolers and bare tube coolers in sulphuric acid plants. The results of laboratory, pilot plant and commercial trials show that in this way a safe operation of sulphuric acid coolers is possible on a long-term basis.

1982-05-01

295

Initiation of depleted uranium oxide and spent fuel testing for the spent fuel sabotage aerosol ratio programme  

Energy Technology Data Exchange (ETDEWEB)

We provide a detailed overview of an on-going, multinational test programme that is developing aerosol data for some spent fuel sabotage scenarios on spent fuel transport and storage casks. Experiments are being performed to quantify the aerosolised materials plus volatilised fission products generated from actual spent fuel and surrogate material test rods, due to impact by a high-energy/density device. The programme participants in the United States plus Germany, France and the United Kingdom, part of the international Working Group for Sabotage Concerns of Transport and Storage Casks (WGSTSC) have strongly supported and coordinated this research programme. Sandia National Laboratories has the lead role for conducting this research programme; test programme support is provided by both the US Department of Energy and the US Nuclear Regulatory Commission. We provide a summary of the overall, multiphase ...

2004-07-01

296

Initiation of depleted uranium oxide and spent fuel testing for the spent fuel sabotage aerosol ratio programme  

International Nuclear Information System (INIS)

We provide a detailed overview of an on-going, multinational test programme that is developing aerosol data for some spent fuel sabotage scenarios on spent fuel transport and storage casks. Experiments are being performed to quantify the aerosolised materials plus volatilised fission products generated from actual spent fuel and surrogate material test rods, due to impact by a high-energy/density device. The programme participants in the United States plus Germany, France and the United Kingdom, part of the international Working Group for Sabotage Concerns of Transport and Storage Casks (WGSTSC) have strongly supported and coordinated this research programme. Sandia National Laboratories has the lead role for conducting this research programme; test programme support is provided by both the US Department of Energy and the US Nuclear Regulatory Commission. We provide a summary of the overall, multiphase ...

297

Initiation of depleted uranium oxide and spent fuel testing for the spent fuel sabotage aerosol ratio program.  

Energy Technology Data Exchange (ETDEWEB)

The authors provide a detailed overview of an on-going, multinational test program that is developing aerosol data for some spent fuel sabotage scenarios on spent fuel transport and storage casks. Experiments are being performed to quantify the aerosolized materials plus volatilized fission products generated from actual spent fuel and surrogate material test rods, due to impact by a high-energy-density device. The program participants in the United States plus Germany, France and the United Kingdom, part of the international Working Group for Sabotage Concerns of Transport and Storage Casks (WGSTSC) have strongly supported and coordinated this research program. Sandia National Laboratories has the lead role for conducting this research program; test program support is provided by both the US Department of Energy and the US Nuclear Regulatory Commission. The authors provide a summary of the overall, ...

2004-08-01

298

Initiation of depleted uranium oxide and spent fuel testing for the spent fuel sabotage aerosol ratio program  

International Nuclear Information System (INIS)

The authors provide a detailed overview of an on-going, multinational test program that is developing aerosol data for some spent fuel sabotage scenarios on spent fuel transport and storage casks. Experiments are being performed to quantify the aerosolized materials plus volatilized fission products generated from actual spent fuel and surrogate material test rods, due to impact by a high-energy-density device. The program participants in the United States plus Germany, France and the United Kingdom, part of the international Working Group for Sabotage Concerns of Transport and Storage Casks (WGSTSC) have strongly supported and coordinated this research program. Sandia National Laboratories has the lead role for conducting this research program; test program support is provided by both the US Department of Energy and the US Nuclear Regulatory Commission. The authors provide a summary of the overall, ...

299

Inspection pig for gas pipeline  

Energy Technology Data Exchange (ETDEWEB)

The ultrasonic inspection pig system was described as being under development. This system was said to adopt the unique wheel type ultrasonic sensor which does not need couplant. This pig was designed to detect external corrosion in long-distance pipelines without interruption of the gas service. The wall-thickness measurement performance test and the travel performance test of the inspection pig in the test line confirmed that these performances satisfied the development specifications. However, the effect induced by the inner surface properties of the pipe and the influence of the pipe`s performance over long distances and for a long period of time still needed to be verified in an actual gas pipeline, and while the pipeline was actually in service. Improvements to the prototype model of the inspection pig were expected to include combinations of inspection pigs, with increases in battery and memory ...

1992-12-31

300

Some fatty acids used for latent heat storage: thermal stability and corrosion of metals with respect to thermal cycling  

Energy Technology Data Exchange (ETDEWEB)

The present study includes thermal stability of some fatty acids as phase change materials (PCMs). The selected fatty acids were stearic, palmitic, myristic and lauric acid with melting temperatures between 40-63{sup o}C and industrial-grade with 90-95% purity. Latent heat storage capacity and phase transition temperature of the PCMs were determined by Differential Scanning Calorimetry (DSC) technique as a function of after repeated thermal cycles such as 40, 410, 700 and 910. The present work also comprises the investigation of corrosion resistance of some construction materials to the fatty acids over a long period. The containment materials tested were stainless steel (SS 304 L), carbon steel (steel C20), aluminium (Al) and copper (Cu). Gravimetric analysis as mass loss (mg/cm{sup 2}), corrosion rate (mg/day) and a microscopic or metallographic investigation were performed for corrosion ...

2003-05-01

301

Heavy Metals in Vehicles II  

Wastenet

Hexavalent chromium in corrosion preventive coating 64 ...To prevent corrosion of rims, weights can be provided with a coating. ...integrated clips brought up technical problems due to corrosion

302

Corrosive Fumes Equipment on Environmental Expert  

Wastenet

... Corrosive Fumes Equipment on Environmental Expert Find and compare a variety of corrosive fumes equipment on the world's largest environmental industry portal. View ...

303

Corrosion Inhibitors Equipment on Environmental Expert  

Wastenet

... Corrosion Inhibitors Equipment on Environmental Expert Find and compare a variety of corrosion inhibitors equipment on the world's largest environmental industry portal. View ...

304

Photovoltaic module energy rating procedure. Final subcontract report  

Energy Technology Data Exchange (ETDEWEB)

This document describes testing and computation procedures used to generate a photovoltaic Module Energy Rating (MER). The MER consists of 10 estimates of the amount of energy a single module of a particular type (make and model) will produce in one day. Module energy values are calculated for each of five different sets of weather conditions (defined by location and date) and two load types. Because reproduction of these exact testing conditions in the field or laboratory is not feasible, limited testing and modeling procedures and assumptions are specified.

1998-01-01

305

Full-length fuel rod behavior under severe accident conditions  

Energy Technology Data Exchange (ETDEWEB)

This document presents an assessment of the severe accident phenomena observed from four Full-Length High-Temperature (FLHT) tests that were performed by the Pacific Northwest Laboratory (PNL) in the National Research Universal (NRU) reactor at Chalk River, Ontario, Canada. These tests were conducted for the US Nuclear Regulatory Commission (NRC) as part of the Severe Accident Research Program. The objectives of the test were to simulate conditions and provide information on the behavior of full-length fuel rods during hypothetical, small-break, loss-of-coolant severe accidents, in commercial light water reactors.

1992-12-01

306

Neutron radiography at the University of Michigan's Phoenix Memorial Laboratory  

International Nuclear Information System (INIS)

Real-time neutron radiography (RTNR) is rapidly becoming a valuable tool for nondestructive testing and basic research with a wide variety of applications. The Phoenix Memorial Laboratory (PML) at the University of Michigan has developed an RTNR facility and has been using this facility to study several phenomena of interest to researchers in many areas. These phenomena include imaging of the internal fluid flow in gas turbine engine nozzles and coking and debris deposition in several gas turbine nozzles. This paper presents a summary of the technique and facilities involved in these applications.

1990-06-10

307

Electromagnetic coupling of high-altitude, nuclear electromagnetic pulses  

International Nuclear Information System (INIS)

We have used scale models to measure the predicted coupling of electromagnetic fields simulating the effects of high-altitude nuclear electromagnetic pulses (HEMP) on the interior surfaces of electronic components. Predictive tools for exterior coupling are adequate. For interior coupling, however, such tools are in their infancy. Our methodological approach combines analytical, computational, and laboratory techniques in a complementary way to take advantage of their separate strengths. Computer models are a promising tool, as they can be used to treat complex objects with arbitrary shapes, dielectrics, and cables, and multiple apertures. Laboratory tests can expand the domain of investigation even further.

1984-11-01

308

Mutation analysis of KRAS prior to targeted therapy in colorectal cancer: development and evaluation of quality by a European external quality assessment scheme  

British Library Electronic Table of Contents (United Kingdom)

In Europe, the use of anti-EGFR monoclonal antibodies is restricted to Kirsten RAS (KRAS) wild-type colorectal tumors. Information on the KRAS status of the patients tumor is thus key for clinical practice; however, there is little guidance or definition on which KRAS mutations to assess and how to assess them. To ensure the consistency and the quality of KRAS test results in Europe, an interlaboratory control network needs to be set up. This pilot study aimed to identify the variables that need to be assessed in a quality control scheme and to provide a first assessment in a selected set of laboratories. Fourteen different tumor cases were circulated between 13 laboratories by a central laboratory acting as the referent for the mutation status determination. This study illustrated that of...

2011-01-01

309

ESTABLISHMENT OF AN ENVIRONMENTAL CONTROL TECHNOLOGY LABORATORY WITH A CIRCULATING FLUIDIZED-BED COMBUSTION SYSTEM  

Energy Technology Data Exchange (ETDEWEB)

This report is to present the progress made on the project ''Establishment of an Environmental Control Technology Laboratory (ECTL) with a Circulating Fluidized-Bed Combustion (CFBC) System'' during the period July 1, 2004 through September 30, 2004. The following tasks have been completed. First, renovation of the new Combustion Laboratory and the construction of the Circulating Fluidized-Bed (CFB) Combustor Building have started. Second, the design if the component parts of the CFBC system have been reviewed and finalized so that the drawings may be released to the manufacturers during the next quarter. Third, the experiments for solid waste (chicken litter) incineration have been conducted using a Thermogravimetric Analyzer (TGA). This is in preparation for testing in the simulated fluidized-bed combustor. The experimental results from this study are presented in this report. Finally, ...

2004-10-30

310

Presence of pathogenic microorganisms in power-plant cooling waters. Report for October 1, 1979-September 30, 1981  

Energy Technology Data Exchange (ETDEWEB)

Cooling waters from eleven geographically disparate power plants were tested for the presence of Naegleria fowleri and Legionella pneumophila (LDB). Control source waters for each plant were also tested for these pathogens. Water from two of the eleven plants contained pathogenic Naegleria, and infectious Legionella were found in seven of the test sites. Pathogenic Naegleria were not found in control waters, but infectious Legionella were found in five of the eleven control source water sites. Concentrations of nitrite, sulfate, and total organic carbon correlated with the concentrations of LDB. A new species of Legionella was isolated from one of the test sites. In laboratory tests, both Acanthamoeba and Naegleria were capable of supporting the growth of Legionella pneumophila.

1982-10-01

311

Core testing of zinc/air refuelable battery modules  

Energy Technology Data Exchange (ETDEWEB)

We are developing a refuelable zinc/air battery (6-cells) for evaluation under the five USABC `core` test protocols. In the first half of the two year project ($1OOK, FY1997), an advanced refuelable design was developed, fabricated and tested at power levels up to 415 W. Performance matched or exceeded that of earlier multicell systems. A computer program was developed for automated data acquisition and drive cycle simulation. Small mockup cells (80 cm 2) were constructed for rapid testing of components. In the follow-on effort (FY1998, $1OOK) we will make minor advances in system design and fabrication efficiency, and seek to improve cathode performance and life, before delivery of two final units for test at DOE laboratory.

1998-08-20

312

Replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory  

Energy Technology Data Exchange (ETDEWEB)

The DOE-Idaho Operations Office (DOE-ID) has prepared an environmental assessment (EA) on the replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory at the Idaho National Engineering Laboratory (INEL). The purpose of this project is to replace the existing Health Physics Instrumentation Laboratory (HPIL) with a new facility to provide a safe environment for maintaining and calibrating radiation detection instruments used at the Idaho National Engineering Laboratory. The existing HPIL facility provides portable health physics monitoring instrumentation and direct reading dosimetry procurement, maintenance and calibration of radiation detection instruments, and research and development support-services to the INEL and others. However, the existing facility was not originally designed for laboratory activities and does ...

1995-05-01

313

The use of high-pressure water jetting to remove the corrosion deposit from samples of the WSGHWR primary circuit pipework  

International Nuclear Information System (INIS)

A series of tests has been carried out to determine the operating conditions required to remove the corrosion deposit from samples cut from Winfrith Steam Generating Heavy Water Reactor (WSGHWR) primary circuit pipework by submerged water jetting. Two types of samples were used - one set subjected to the normal annual reactor decontamination using TURCO reagents, the other set having been given a LOMI treatment in addition. Tests showed that useful decontamination factors could be achieved on both types of sample, but significantly less severe operating conditions were required to decontaminate the LOMI treated samples. A decontamination factor of 10 was achieved on TURCO treated samples at 360 Bar; only 200 Bar was required to achieve the same decontamination factor on LOMI treated samples. No metal erosion of the stainless steel substrate was found to occur at these pressures. (author).

314

Experimental investigation on denting in PWR steam generators: causes and corrective actions  

International Nuclear Information System (INIS)

Denting studies have been undertaken in order to assess the influence of the most important parameters which could initiate corrosion of the carbon steel occurring in the tube-tube support plate crevices of some PWR steam generators. Tests have been carried out in model boilers where feedwater was polluted with sea or river water. Specific effects of chloride or sulfate and influence of oxygen content, magnetite addition and pH value were investigated. In magnetite prepacked crevices, denting is obtained within 1000 hrs for seawater pollution of 0.3 ppm chloride at the blowdown. In neutral chloride or in river water, denting is observed only with oxygen addition. Denting prevention is effective in the case of an on-line addition of phosphate, boric acid, or calcium hydroxide. For denting stopping, boric acid or calcium hydroxide is efficient even with a high seawater pollution. Soaks cannot stop denting if they are not followed by an on-line ...

315

Experimental investigation on denting in PWR steam generators, causes and corrective actions  

International Nuclear Information System (INIS)

Denting studies have been undertaken in order to assess the influence of the most important parameters which could initiate corrosion of the carbon-steel occurring in the tube-tube support plate crevices of some PWR steam generators. Tests have been carried out in model boilers, feedwater being polluted with sea or river water. Specific effect of chloride or sulfate and influence of oxygen content, magnetite addition and pH value were investigated. In magnetite prepacked crevices, denting is obtained within 1000 hours for sea-water pollution of 0.3 ppm chloride at the blowdown. In neutral chloride or in river water denting is observed only with oxygen addition. Denting prevention is effective in the case of an on-line addition of phosphate, boric acid or calcium hydroxide. For denting stopping, boric acid or calcium hydroxide is efficient even with a high sea-water pollution. Soaks cannot stop denting if they are not followed by an on-line ...

1985-03-01

316

Effect of surface treatemnts on stress corrosion cracking of alloy 800 in alkaline solutions. Alloy 800 no alkaline yoekichu no ouryoku fushoku ware ni oyobosu hyomenkako no eikyo  

Energy Technology Data Exchange (ETDEWEB)

Effect of the coverage of shot peening, the surface roughness and shot shape, etc. on the stress corrosion cracking (SCC) of Alloy 800 in alkaline solutions was studied. Alloy 800 specimens were cracked in boiling alkaline solutions at the potntial range of {minus} 100 to 0mV in the boiling 50%NaOH+0.3%SiO {sub 2} solution. U bend specimens were tested under the polarized condition at the controlled potential to 0mV, showing that shot peened specimens cracked more easily. Tests of specimens with the same hardness showed that specimens hardened by cold working showed the higher susceptivity than that of surface hardened specimens. In these connections, U bend specimens of higher shot peened coverage were cracked at conditions of 593K and 10%NaOH solution. O-ring specimens of smaller stress level did not show any cracks independent of surface treatments. 8 refs., 9 figs., 5 tabs.

1990-03-15

317

Effect of crevice environment PH on corrosion damage of horizontal steam generator tubes  

Energy Technology Data Exchange (ETDEWEB)

In support of a project on lifetime calculation experiments were carried out to evaluate the resistance to environmentally assisted cracking (EAC) of steam generator tubes during operation. Estimations of the incubation period for crack initiation and the threshold K value, K{sup Iscc}, and the crack growth rate were made to predict evolution of damage in tube walls. The paper summarizes results of experiments of C ring specimen for the initiation testing and results of SENT (single edge notch tensile) specimen for the crack growth rate (CGR) testing. The specimens were exposed to concentrated environments at elevated temperatures simulating crevice environments in secondary side crevices in horizontal steam generators. The results show that the material of SG tubes is sensitive to transgranular environmentally assisted cracking in the three basic concentrated environments used, alkaline, neutral and acid. The most ...

2002-07-01

318

Effect of crevice environment PH on corrosion damage of horizontal steam generator tubes  

International Nuclear Information System (INIS)

In support of a project on lifetime calculation experiments were carried out to evaluate the resistance to environmentally assisted cracking (EAC) of steam generator tubes during operation. Estimations of the incubation period for crack initiation and the threshold K value, K"I"s"c"c, and the crack growth rate were made to predict evolution of damage in tube walls. The paper summarizes results of experiments of C ring specimen for the initiation testing and results of SENT (single edge notch tensile) specimen for the crack growth rate (CGR) testing. The specimens were exposed to concentrated environments at elevated temperatures simulating crevice environments in secondary side crevices in horizontal steam generators. The results show that the material of SG tubes is sensitive to transgranular environmentally assisted cracking in the three basic concentrated environments used, alkaline, neutral and acid. The most corrosive ...

2002-05-05

319

Crud removal performance with ion exchange resins in BWR plants  

Energy Technology Data Exchange (ETDEWEB)

It is needless to say that one of the most important roles of the condensate demineralizer in Japanese boiling water reactors (BWR) is to eliminate such impurities during accidental occurrence of sea water leakage from condensate cooling system. Ion exchange resins packed in condensate demineralizer have also been expected to decrease crud, or corrosion products (CP) in condensate water in order to finally reduce activated corrosion products (ACP) in the reactor coolant loop. It is perceived that crud removal ability of a condensate demineralizer has been improved year by year. And we call this phenomenon as `Aging Effect`. Typical property changes of aged cation exchange resin consisted of an increase of water retention capacity and a change of surface texture. Based on these findings, we formulated a new concept and developed new gel type ion exchange resins for the better crud removal. The results from column tests using ...

1996-01-01

320

The influence of CeO_2 on the corrosion resistance of laser remelted alloy spray coatings on steel  

International Nuclear Information System (INIS)

The main compositions of iron-base amorphous self-fluxing alloy powders of 150 mesh, used in this work, are Fe, Cr, Ni, W, Mo, B, Si and C. The ranges of each element in at% are (65-70)Fe, (3-5)Cr, (2-4)Ni, (2-4)W, (1-2)Mo, (10-14)B, (4-7)Si and (2-3)C. The atomic ratio of metal-metalloid is about 80:20, so this alloy is abbreviated as M_8_0X_2_0. The material on which coatings were deposited is 1020 steel, austenitized for 1h at 880 C, water quenched, and tempered at 180 C for 1h. This heat treatment resulted in a low carbon martensite structure with a hardness of HRC35-45. After cleaning, shot blasting and preheating the steel to about 200 C, the authors sprayed a thin Ni-Al alloy layer of about 0.1--0.15mm in thickness onto the specimen by means of an oxygen-acetylene torch to provide better bonding of the coating with substrate. Then the M_8_0X_2_0 and M_8_0X_2_0+8%CeO_2 alloy coatings were sprayed to a thickness of about 0.6--0.8mm. The CeO_2 was added as particles of 200 mesh, ...

323

1996 Hazardous Substances and New Organisms No. 30  

Wastenet

ii) Flammability: (iii) A capacity to oxidise: (iv) Corrosiveness: (v) Toxicity (including chronic ...an explosion or fire: (d) For substances with corrosive properties: (i) To reduce the ...likelihood of any unintended corrosion:(ii) To control the adverse effects of any corrosion:

324

Use of organic water treatment chemicals  

International Nuclear Information System (INIS)

For better understanding and proper use of organic chemicals addition data are needed, including kinetic data on the scavenging reactions in actual cycles, data on ambient temperature stability and decomposition, sampling and analsyis information, data on effects in a case of fire, and more corrosion data. Use of these chemicals for layup of boilers and other equipment needs to be evaluated for each application. After a preliminary evaluation, such as outlined in this report, every new water treatment chemical should be evaluated in at least two month test in actual steam cycle. (orig.).

325

Substantiation of recommendations for ensuring the design service life of heat-transfer tubes used in a PGV-1000MKP steam generator  

Science.gov (United States)

We present the results obtained from tests and studies carried out on the model of tube bundles for a PGV-1000 horizontal steam generator that were conducted for experimentally substantiating the design service life of a steam generator tube bundle intended for use at new nuclear power stations equipped with a PGV-1000MKP steam generator. Measures taken to minimize the incipience and development of local corrosion damage to the heat-transfer tubes and ensure their design service life are substantiated and confirmed.

2011-03-01

326

Resistance of the alloy steel used in the fuel gas desulphurization installations  

International Nuclear Information System (INIS)

The results have been presented of DC polarization and exposure investigations of alloy steels used as construction materials in flue gas desulphurization installations. on the base of analysis of composition of investigated steels and results of polarization studies, conditions have been discussed in which the pitting resistance equivalent (PRE) should be used. Among tested steels the significantly highest resistance to pitting corrosion is exhibited by 654SMO steel, classified as the super austenitic grade. (author). 14 refs, 3 figs, 2 tabs.

327

Low temperature latent heat thermal energy storage - heat storage materials  

Energy Technology Data Exchange (ETDEWEB)

Heat-of-fusion storage materials for low temperature latent heat storage in the temperature range 0-120 C are reviewed. Organic and inorganic heat storage materials classified as paraffins, fatty acids, inorganic salt hydrates and eutectic compounds are considered. The melting and freezing behavior of the various substances is investigated using the techniques of Thermal Analysis and Differential Scanning Calorimetry. The importance of thermal cycling tests for establishing the long-term stability of the storage materials is discussed. Finally, some data pertaining to the corrosion compatibility of heat-of-fusion substances with conventional materials of construction is presented.

1983-01-01

328

Estimation of armature condition in concrete with gamma-absorption method  

International Nuclear Information System (INIS)

Bases of the algorithm for assessing the reinforcement status in reinforced concrete products by gamma-absorption method are presented. Analytical equations are obtained for estimation of error of the parameter characterizing the degree of reinforcement destruction. It is recommended to use high-energy Bremsstrahlung sources-betatrons of 4-10 MeV maximum energy for testing products of 500-600 mm thick. Linear radiation attenuation factor (LAF) of concrete in estimated equation is replaced by effective LAF of concrete, and LAF of reinforcement and corrosion materials - by differential LAF. Corresponding LAF of nonevident form in the algorithm is assessed by the results of processing of direct-shadow radiographs of defectometers

329

Electrical impact of Mt. St. Helens  

Energy Technology Data Exchange (ETDEWEB)

Ash fallout from the Mount Saint Helens eruptions affected high-voltage transmission in a four-state area as volatile gases caused conductivity changes and corrosion. The Bonneville Power Authority (BPA) found that it was possible to maintain electric service except for a few short, localized outages. Cleaning ash from transformers and substations was the first priority. Tests were underway within 48 hours to determine ash characteristics and cleaning procedures. A summary to what happened and what was learned is presented in two lists. (DCK)

1981-08-01

330

Corrosion performance of tube support materials  

International Nuclear Information System (INIS)

The problem of denting in steam generators leads to change in the conception of the tube support plates. A new material is now used for this component, a 13% Cr steel, which composition has been adjusted for weldability and mechanical resistance criteria. The geometry of trefoil support plate (TSP) has also been improved, using a broached TSP (quadrifoiled holes) instead of a drilled TSP. Tests have been performed on 13% Cr and C-steel broached TSP, and drilled TSP, to confirm the better resistance to denting of this new configuration.

1985-03-01

331

Non-Traditional In Situ Vitrification - A Technology Demonstration at Los Alamos National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

The Department of Energy (DOE) Subsurface Contamination Focus Area (SCFA) sponsored a technology demonstration of non-traditional in situ vitrification (NTISV) at Los Alamos National Laboratory (LANL). The project team for this demonstration included MSE Technology Applications, Inc., Geosafe Corporation, and LANL. The technology demonstration involved the performance of two large-scale test melts. The first, referred to as the ''cold'' test, was performed on a simulated absorption bed that contained surrogate contaminants. The cold test was conducted in April 1999. The second demonstration, referred to as the ''hot'' test, took place at LANL's Material Disposal Area (MDA) V in April 2000. The hot test was conducted on a portion of an absorption bed that received radionuclide and ...

2003-02-25

332

Converting Simulated Sodium-bearing Waste into a Single Solid Waste Form by Evaporation: Laboratory- and Pilot-Scale Test Results on Recycling Evaporator Overheads  

Energy Technology Data Exchange (ETDEWEB)

Conversion of Idaho National Engineering and Environmental Laboratory radioactive sodium-bearing waste into a single solid waste form by evaporation was demonstrated in both flask-scale and pilot-scale agitated thin film evaporator tests. A sodium-bearing waste simulant was adjusted to represent an evaporator feed in which the acid from the distillate is concentrated, neutralized, and recycled back through the evaporator. The advantage to this flowsheet is that a single remote-handled transuranic waste form is produced in the evaporator bottoms without the generation of any low-level mixed secondary waste. However, use of a recycle flowsheet in sodium-bearing waste evaporation results in a 50% increase in remote-handled transuranic volume in comparison to a non-recycle flowsheet.

2004-01-01

333

Asphalt emulsion sealing of uranium mill tailings. 1980 annual report  

International Nuclear Information System (INIS)

Studies of asphalt emulsion sealants conducted by the Pacific Northwest Laboratory have demonstrated that the sealants are effective in containing radon and other potentially hazardous material within uranium tailings. The laboratory and field studies have further demonstrated that radon exhalation from uranium tailings piles can be reduced by greater than 99% to near background levels. Field tests at the tailings pile in Grand Junction, Colorado, confirmed that an 8-cm admix seal containing 22 wt% asphalt could be effectively applied with a cold-mix paver. Other techniques were successfully tested, including a soil stabilizer and a hot, rubberized asphalt seal that was applied with a distributor truck. After the seals were applied and compacted, overburden was applied over the seal to protect the seal from ultraviolet degradation.

334

Scratch and Corrosion Resistance of an Aluminum Flange with an Electron Beam Modified Seal Edge  

Science.gov (United States)

Scratch and Corrosion Resistance of an Aluminum Flange with an Electron Beam Modified Seal Edge

2011-01-01

336

Corrosion resistance of modern austenitic-ferritic (duplex) stainless steel. Corrosion of special types. (Review)  

International Nuclear Information System (INIS)

Recent data on resistance of modern corrosion-resistant austenitic-ferritic steels to different types of corrosion are generalized. It is shown that these steels are characterized by high resistance to general corrosion in acid, alkali, chloride and other solutions, are not inclined to intercrystalline, pitting and crevice corrosion and are noted for high resistance to corrosion cracking and corrosion fatigue. All this is combined with technological and economical effectiveness. It is advisible to use these steels instead of highly-alloyed and expensive steels and alloys in chemical, power and other industries. 59 refs.; 2 tabs.

337

Characterization of aluminum surfaces: Sorption and etching  

Science.gov (United States)

Aluminum, due to its low density and low cost, is a key material for future lightweight applications. However, like other structural materials, aluminum is subject to various forms of corrosion damage that annually costs the United States approximately 5% of its GNP [1]. The main goal is to investigate the effects of various solution anions on aluminum surfaces, and specifically probe pit initiation and inhibition. Using surface analysis techniques including X-ray photoelectron spectroscopy, Auger electron spectroscopy, and scanning electron microscopy, results have been correlated with those obtained from electrochemical methods and a radiolabeling technique developed in the Wieckowski laboratory. Analysis of data has indicated that important variables include type of anion, solution pH, and applied electrode potential. While aggressive anions such as chloride are usually studied to elucidate corrosion processes to work ...

2001-01-01

338

Changes in the flexural strength of engineering ceramics after high temperature sodium corrosion test. Influence after sodium exposure for 1000 hours  

International Nuclear Information System (INIS)

Engineering ceramics have excellent properties such as high strength, high hardness and high heat resistance compared with metallic materials. To apply the ceramic in fast reactor environment, it is necessary to evaluate the sodium compatibility and the influence of sodium on the mechanical properties of ceramics. In this study, the influence of high temperature sodium on the mechanical properties of sintered ceramics of conventional and high purity Al_2O_3, SiC, SiAlON, AlN and unidirectional solidified ceramics of Al_2O_3/YAG eutectic composite were investigated by means of flexure tests. Test specimens were exposed in liquid sodium at 823K and 923K for 3.6Ms. There were no changes in the flexural strength of the conventional and high purity Al_2O_3, AlN and Al_2O_3/YAG eutectic composite after the sodium exposure at 823K. On the contrary, the decrease in the flexural strength was observed in SiC and SiAlON. After the sodium exposure at 923K, ...

339

Pitting corrosion  

International Nuclear Information System (INIS)

Pitting corrosion is a kind of electrolytic corrosion by which the surface of a material is locally affected owing to inhomogeneities on the part of the material or medium. The paper deals briefly with questions relating to the importance, to parameters medium or materialwise, influence on production and construction, as well as the general conditions for pitting corrosion. In particular oxygen corrosion in unalloyed and low-alloy steel, and pitting corrosion in ferritic chromium-steel and austenitic chromium-nickel (molybdenum) steel is described. (DG).

340

Corrosion in power plant condensers  

International Nuclear Information System (INIS)

A historical overview of corrosion problems found in power plant condensers and mitigation procedures is presented. The paper is organized according to alloy type and failure mode. Alloys considered are copper-base alloys, stainless steels and titanium. Failure modes discussed include erosion-corrosion, sulfide attack, environmentally assisted cracking, galvanic corrosion, steam condensate corrosion, pitting corrosion, and dealloying. Mitigation procedures discussed include cathodic protection, ferrous ion injection, as well as tube cleaning and layup practices.

341

HISTORICAL AMERICAN ENGINEERING RECORD - IDAHO NATIONAL ENGINEERING AND ENVIRONMENTAL LABORATORY, TEST AREA NORTH, HAER NO. ID-33-E  

Energy Technology Data Exchange (ETDEWEB)

Test Area North (TAN) was a site of the Aircraft Nuclear Propulsion (ANP) Project of the U.S. Air Force and the Atomic Energy Commission. Its Cold War mission was to develop a turbojet bomber propelled by nuclear power. The project was part of an arms race. Test activities took place in five areas at TAN. The Assembly & Maintenance area was a shop and hot cell complex. Nuclear tests ran at the Initial Engine Test area. Low-power test reactors operated at a third cluster. The fourth area was for Administration. A Flight Engine Test facility (hangar) was built to house the anticipated nuclear-powered aircraft. Experiments between 1955-1961 proved that a nuclear reactor could power a jet engine, but President John F. Kennedy canceled the project in March 1961. ANP facilities were adapted for new reactor projects, the most important of which were Loss of Fluid ...

2005-02-01

342

Steam generator local water chemistry and SCC of austenitic steel  

Energy Technology Data Exchange (ETDEWEB)

The titanium stabilized austenitic steel similar to the type of 321 is sensitive to the stress corrosion crackingunder horizontal steam generator operating condition. SCC was observed under crevice corrosion parameters and has resulted in the transgranular or intergranular cracking at the both, components primary collectors and heat exchange tubes. The crevice environment is characterized by aggressive impurities and 'non aggressive' compounds. Sulfates and chlorides as aggressive species and silicates and alumino-silicates as 'non aggressive' species on the other hand are present in significant amount in the crevice environment under operating condition. Local water chemistry parameters were evaluated with MULTEQ Code. As input data the measured operational values of local and bulk environments have been used. The determined parameters were compared with the results of thread hole environment analyses and ...

1998-07-01

343

Secondary system chemistry control and sludge management  

International Nuclear Information System (INIS)

Since 1975 All Volatile Treatment (AVT) has been the preferred method for controlling the secondary system operating environment in Westinghouse PWR plants. However, since AVT provides no buffering action against corrodent species present in the water as trace contaminants, utilities have initiated programs which combine control of contaminant ingress with total steam generator sludge management. The earliest applications of boric acid, to control denting type corrosion, began in 1978 and have continued up to the present time. Boric Acid has also been added as an inhibitor for SCC/IGA type corrosion since 1985. There are now approximately 30 plants operating with boric acid or boric acid/morpholine chemistry in the secondary system, and a growing number of plants where morpholine is being used as an additive to maintain pH and reduce iron transport attributable to erosion/corrosion. The impact of these modifications in the ...

344

Investigation on corrosion and wear behaviors of nanoparticles reinforced Ni-based composite alloying layer  

Energy Technology Data Exchange (ETDEWEB)

In order to investigate the role of amorphous SiO{sub 2} particles in corrosion and wear resistance of Ni-based metal matrix composite alloying layer, the amorphous nano-SiO{sub 2} particles reinforced Ni-based composite alloying layer has been prepared by double glow plasma alloying on AISI 316L stainless steel surface, where Ni/amorphous nano-SiO{sub 2} was firstly predeposited by brush plating. The composition and microstructure of the nano-SiO{sub 2} particles reinforced Ni-based composite alloying layer were analyzed by using SEM, TEM and XRD. The results indicated that the composite alloying layer consisted of {gamma}-phase and amorphous nano-SiO{sub 2} particles, and under alloying temperature (1000 deg. C) condition, the nano-SiO{sub 2} particles were uniformly distributed in the alloying layer and still kept the amorphous structure. The corrosion resistance of composite alloying layer was investigated by an electrochemical method in ...

2008-04-30

345

Investigation on corrosion and wear behaviors of nanoparticles reinforced Ni-based composite alloying layer  

International Nuclear Information System (INIS)

In order to investigate the role of amorphous SiO2 particles in corrosion and wear resistance of Ni-based metal matrix composite alloying layer, the amorphous nano-SiO2 particles reinforced Ni-based composite alloying layer has been prepared by double glow plasma alloying on AISI 316L stainless steel surface, where Ni/amorphous nano-SiO2 was firstly predeposited by brush plating. The composition and microstructure of the nano-SiO2 particles reinforced Ni-based composite alloying layer were analyzed by using SEM, TEM and XRD. The results indicated that the composite alloying layer consisted of ?-phase and amorphous nano-SiO2 particles, and under alloying temperature (1000 deg. C) condition, the nano-SiO2 particles were uniformly distributed in the alloying layer and still kept the amorphous structure. The corrosion resistance of composite alloying layer was investigated by an electrochemical method in 3.5%NaCl solution. Compared with single ...

2008-04-30

346

Influence of chromium, molybdenum and nitrogen on the corrosion resistance of the Ni-free, austenitic stainless steel Macrofer 2515MoN{sup *} (German alloy No. 1.4653); Einfluss von Chrom, Molybdaen und Stickstoff auf die Korrosionsbestaendigkeit des Ni-freien, austenitischen Edelstahles Macrofer 2515MoN{sup *} (W.-Nr.: 1.4653)  

Energy Technology Data Exchange (ETDEWEB)

Nitrogen alloyed, Ni-free, austenitic stainless steels comprising of more than 1 wt.-% nitrogen are a new group of alloys with promising properties. They show a very interesting combination of high strength and toughness with a high corrosion resistance. This combination of properties make the alloys not only suitable for fasteners but also for parts for medical and dental applications. This work shows the influence of chromium, molybdenum and nitrogen on the corrosion resistance of Fe25Mn-alloys in media typical for the above mentioned applications. According to these results Fe25Mn-alloys with appr. 20 wt.-% chromium, about 3 wt.-% molybdenum and appr. 1,3 wt.-% nitrogen have an excellent corrosion resistance in Ringer solution, artificial saliva and artificial sweat. The critical pitting temperature (CPT) as well as the critical crevice temperature (CCT) with 61 C respectively 37 C tested according ...

1998-07-01

347

Fabrication of continuous mesoporous organic-inorganic nanocomposite films for corrosion protection of stainless steel in PEM fuel cells  

International Nuclear Information System (INIS)

Graphical abstract: Ordered mesoporous organic-inorganic composite film has been achieved by sol-gel and spin-coating techniques. We believe that the mesoporous composite films have a potential application as a protect coating of bipolar plate material. Display Omitted Research highlights: ? Ordered mesoporous composite film was deposited on the 304 stainless steel. ? This composite film exhibited excellent protective performance in 0.5 M H_2SO_4. ? The film exhibited a high surface tension with water contact angle close to 90"o. - Abstract: The organic-inorganic composite film was deposited on the 304 stainless steel as bipolar plate material for proton exchange membrane fuel cells by spin-coating method. As shown by XRD, N_2 adsorption-desorption and TEM, the composite films exhibit ordered mesoporous structures. The corrosion tests in 0.5 M H_2SO_4 system displayed that, compared with 304SS, the composite films made ...

2011-04-01

348

Investigation of passive films on nickel Alloy 690 in lead-containing environments  

Energy Technology Data Exchange (ETDEWEB)

Passive films formed on Alloy UNS N06690 were investigated in simulated crevice chemistries. It was found the role of lead in corrosion processes is strongly dependent on the pH value of the testing solutions. At pH 1.5 the effect of lead is narrowly noticeable; while at pH 12.7, lead has a significant influence on the electrochemical performance of alloy UNS N06690. The lead alters the surface morphologies at both pH and account for higher hydroxide content in the surface film at pH 12.7. The lead incorporation hinders the formation of spinel oxides during the passivation in alkaline solution. Nanoindentation tests indicate a significant lead-induced degradation in the mechanical properties of passive films. The passivation degradation is attributed to detrimental effects of lead via interrupting the dehydration process and hindering the formation of protective layers on the alloy surface.

2008-09-01

349

Evaluation of a permeable reactive barrier technology for use at Rocky Flats Environmental Technology Site (RFETS)  

Energy Technology Data Exchange (ETDEWEB)

Three reactive materials were evaluated at laboratory scale to identify the optimum treatment reagent for use in a Permeable Reactive Barrier Treatment System at Rocky Flats Environmental Technology Site (RFETS). The contaminants of concern (COCS) are uranium, TCE, PCE, carbon tetrachloride, americium, and vinyl chloride. The three reactive media evaluated included high carbon steel iron filings, an iron-silica alloy in the form of a foam aggregate, and a peculiar humic acid based sorbent (Humasorb from Arctech) mixed with sand. Each material was tested in the laboratory at column scale using simulated site water. All three materials showed promise for the 903 Mound Site however, the iron filings were determined to be the least expensive media. In order to validate the laboratory results, the iron filings were further tested at a pilot scale (field columns) using actual site water. ...

2000-01-01

350

Automated real-time testing (ARTT) for embedded control systems (ECS).  

Energy Technology Data Exchange (ETDEWEB)

Many of today's automated real-time testing systems for embedded systems were developed using expensive custom hardware and software. In this article they describe how to use commercially available off-the-shelf hardware and software to design and develop an automated real-time test systems for Embedded Programmable Logic Controller (PLC) Based Control Systems. The system development began with the implementation of the VALI/TEST Pro testing methodology as a means for structuring the testing. Using this methodology, they were able to decompose system requirement documents for a Personnel Safety System (PSS) into its high, intermediate and detail level requirements. next, the validation procedures for the PSS system were decomposed into testing units called builds, test runs and test cases. To measure the PSS ...

2001-08-09

351

Seismic proving test of heavy component with energy absorbing support. Proving seismic reliability of the system and developing characteristics evaluation equation of energy absorbing support  

International Nuclear Information System (INIS)

The Seismic Proving Test of Heavy Component with Energy Absorbing Supports has been conducted to prove the reliability of advanced seismic technology, supporting heavy component such as PWR steam generator with large capacity energy absorbing supports under the sponsorship of Ministry of Economical Trade and Industry. If energy absorbing supports are adopted for NPP heavy components, support structure of facility will be much simplified due to their seismic energy absorbing effect. The paper describes the results of lead damper element test and seismic test at Tadotsu Laboratory, using 1/2.5 scale PWR Steam Generator model supported by Lead Extraction Damper (LED) and development of characteristics evaluation formula of energy absorbing support. (author)

2003-09-15

352

Nuclear cask testing films misleading and misused  

Energy Technology Data Exchange (ETDEWEB)

In 1977 and 1978, Sandia National Laboratories, located in Albuquerque, New Mexico, and operated for the US Department of Energy (DOE), filmed a series of crash and fire tests performed on three casks designed to transport irradiated nuclear fuel assemblies. While the tests were performed to assess the applicability of scale and computer modeling techniques to actual accidents, films of them were quickly pressed into service by the DOE and nuclear utilities as ``proof`` to the public of the safety of the casks. In the public debate over the safety of irradiated nuclear fuel transportation, the films have served as the mainstay for the nuclear industry. Although the scripts of all the films were reviewed by USDOE officials before production, they contain numerous misleading concepts and images, and omit significant facts. The shorter versions eliminated qualifying statements contained in the longer version, and created false ...

1991-10-01

353

Laboratory studies of the diffusive transport of 137Cs and 60Co through potential waste repository soils  

British Library Electronic Table of Contents (United Kingdom)

Tests using reconstituted samples have been performed to assess the diffusive transport of 137Cs and 60Co through natural regolith materials from a region in South Australia being considered for a radioactive waste repository. A double diffusion cell apparatus made of polycarbonate resin was developed to estimate the effective diffusion (De) and sorption coefficients (Kd) that allowed large withdrawals from the source and collector cells and has enabled tests with low concentrations of radioactivity. An alternative to porous stainless steel filter plates has also been used to reduce uncertainty in test interpretation. Analysis of the transient data used a staged method of the Laplace transform to take into consideration the volume of the samples withdrawn from the apparatus during testing....

2010-01-01

354

Laboratory evaluation of pipeline girth weld imperfections to determine their acceptability in sour gas service  

Energy Technology Data Exchange (ETDEWEB)

The influence of common welding defects such as internal under-cut, incomplete penetration of the root bead, internal concavity and hollow bead have been evaluated in a sour environment. Tests were performed on samples cut from actual pipeline welds. The individual defects were subjected to slow strain rate testing. The samples were then examined by metallography, scanning electron microscopy, and hardness testing. It was established that a threshold stress intensity exists for sulphide stress cracking. The test results were compared to those obtained from samples of the weld and pipe which did not contain any defects. This comparison indicated that the metallurgical variations associated with the presence of a weld are the main factor for sulphide stress cracking rather than any specific defects or geometry. 5 tabs., 9 figs.

1992-12-31

355

Fatigue and creep-fatigue testing of steam filled tubular Alloy 800 specimens  

Energy Technology Data Exchange (ETDEWEB)

A test program was conducted under contract to Sandia National Laboratories to investigate water/steam effects on elevated temperature low cycle fatigue and creep-fatigue of Alloy 800. This report presents interpretation and analysis of the test results. Tubular specimens with water sealed inside were cycled to failure under strain control. Tests were conducted to 616K (650/sup 0/F) and 922K (1200/sup 0/F); some at 922K included tensile or compressive hold periods to simulate creep-fatigue conditions. The tubular specimens showed significantly lower lives than solid bar specimens cycled at equivalent strain ranges. Rough internal surfaces contributed to early crack initiation with these specimens. Inclusion of hold periods caused further large reductions in cycles to failure.

1982-05-01

356

Customized airfoils and their impact on VAWT (Vertical-Axis Wind Turbine) cost of energy  

Science.gov (United States)

Sandia National Laboratories has developed a family of airfoils specifically designed for use in the equatorial portion of a Vertical-Axis Wind Turbine (VAWT) blade. An airfoil of that family has been incorporated into the rotor blades of the DOE/Sandia 34-m diameter VAWT Test Bed. The airfoil and rotor design process is reviewed. Comparisons with data recently acquired from flow visualization tests and from the DOE/Sandia 34-m diameter VAWT Test Bed illustrate the success that was achieved in the design. The economic optimization model used in the design is described and used to evaluate the effect of modifications to the current Test Bed blade. 1 tab., 11 figs., 13 refs.

1990-01-01

357

Carbon dioxide purification through two-stage combustion ENCAP. Final report; Koldioxidrening med tvaastegsforbranning ENCAP. Slutrapport  

Energy Technology Data Exchange (ETDEWEB)

Chemical-looping combustion (CLC), has previously been studied as a method for separating CO{sub 2} during combustion of gaseous fuels. In this project the possibility to apply this process for direct use of solid fuels has been investigated. The following has been accomplished: A 10 kW reactor system for CLC with solid fuels has been designed and built. Tests with solid fuel and metal oxid particles in a laboratory reactor show that it is possible to oxidize solid fuels with metal oxide particles in cyclic testing, thus giving proof of basic concept. They also show how the reaction rate is affected by temperature, steam concentration etc., and, most important of all, that the rates of reaction are realistic. Tests with metal oxide materials available at low costs have been successful. Chemical-looping combustion with solid fuels has a potential to achieve very low costs for separation of CO{sub 2}, ...

2006-06-15

358

A laboratory study on the thermomechanical behaviour of clayey soils  

Energy Technology Data Exchange (ETDEWEB)

The thermomechanical behaviour of clayey soils was examined in a laboratory study because of their importance in some engineering applications such as hydrocarbon extraction from oil-bearing sands and radioactive waste disposal. The slightest temperature variations have been known to have an impact on the mechanical behaviour of clayey soils. In this study, tests were conducted on reconstituted and natural clayey soils using triaxial cells modified to control temperatures. Changes of temperature and stress state were not applied simultaneously. Instead, the tests were divided into two separate sections aimed at studying the thermal and mechanical behaviour of clays. The thermal behaviour tests examined the deformations induced by drainage temperature changes as well as pore-pressure generation and consolidation phenomena. The mechanical behaviour tests, focused on the influence of ...

2000-08-04

359

corrosion and wear resistant ternary Cr-C-N coatings deposited by the ARC PVD process for machining tools and machining parts  

International Nuclear Information System (INIS)

With the deposition of PVD hard coatings on the tools applied in machining operations it is possible to achieve significant improvements in the performance and quality of the machining processes. Depending on the machined material and the operating principle, e.g. turning, milling or drilling, not only different machining parameters but also different coating materials are necessary. In interrupted cut machining of tempered steel, for example, the life time of Ti-C-N coated inserts is several times greater than the Ti-C-N coated ones. This is a result of the favourable thermophysical and tribological properties of Ti-N-C. The potential for tool protection by CrN coatings is a result of the high ductility and low internal stress of this coating materials. CrN films can be deposited with greater film thickness, still maintaining very good adhesion. This paper presents the development of new arc PVD coatings in the system Cr-C-N. Owing to the carbon content in the coating an increased ...

360

Initiation of depleted uranium oxide and spent fuel testing for the spent fuel sabotage aerosol ratio program  

Energy Technology Data Exchange (ETDEWEB)

We provide a detailed overview of an ongoing, multinational test program that is developing aerosol data for some spent fuel sabotage scenarios on spent fuel transport and storage casks. Experiments are being performed to quantify the aerosolized materials plus volatilized fission products generated from actual spent fuel and surrogate material test rods, due to impact by a high energy density device, HEDD. The program participants in the U.S. plus Germany, France, and the U.K., part of the international Working Group for Sabotage Concerns of Transport and Storage Casks, WGSTSC have strongly supported and coordinated this research program. Sandia National Laboratories, SNL, has the lead role for conducting this research program; test program support is provided by both the U.S. Department of Energy and Nuclear Regulatory Commission. WGSTSC partners need this research to better understand potential ...

2004-07-01

361

Advances on experimental techniques for the characterization of THM behaviour of bentonite  

Energy Technology Data Exchange (ETDEWEB)

The design of high level radioactive waste (HLW) repositories in deep geological media in which bentonite clay is proposed as a sealing material leads to the need of further studying the behaviour of highly compacted expansive soils when subjected to mechanical, hydraulic and thermal changes. Laboratory tests may help to understand the processes that take place in the clay barrier under simple and controlled conditions and to develop the governing equations. The laboratory tests enable to isolate the different processes, making their interpretation easier, and provide with fundamental data concerning the parameters to be used in the models. The extremely low permeability of these materials, their avidity for water (high suction) and their high swelling capacity make necessary the modification of the conventional laboratory techniques and procedures to determine basic physical ...

2005-07-01

362

Proper use of sludge-control additives in residential heating oil systems  

Energy Technology Data Exchange (ETDEWEB)

Discussed are various aspects of heating oil `sludge`: How it forms, typical problems it causes, how sludge-control additives work, what should be expected of them, and what happens in a contaminated system when such additives are used. Test results from laboratory and field experiments demonstrate that performance of commercially available additives varies greatly. The concept of `end-of-the-line` treatment is described and compared with bulk fuel treatment. A procedure is described whereby a retailer can test additives himself, and thus determine just what those additives will or will not do for his business. Finally, the economics of an effective treatment program are outlined.

1995-04-01

363

Progress and Plans for R&D and the Conceptual Design of the ILC Main Linacs  

CERN Document Server

The International Linear Collider Main Linacs are based on superconducting accelerator structures operating at 1.3 GHz. The basis for this design has been developed and tested at DESY and R&D is progressing at many laboratories around the world including DESY, Orsay, KEK, FNAL, SLAC, Cornell, and JLAB. The status of the TESLA-style cavities and rf system will be reviewed and parameters for the ILC linac will be described. The role of the different linac test facilities will discussed and the critical items and R&D program to support a Conceptual Design and Technical Design will be outlined.

2005-01-01

364

Product yield and hydrogen consumption selectivity tests for coal liquefaction catalyst development  

Science.gov (United States)

A method for analyzing the experimental results of coal liquefaction reactions which is applicable to a number of aspects of coal liquefaction research and process control, including rapid selectivity and performance screening for catalysts; correlation of laboratory results with process parameters; and optimization of product yield with plant process conditions is described here. Ternary diagrams of product/by-product distributions for the coal liquefaction using Co/Mo catalysts combined with a hyperbolic relationship for the conversion of various hydrocarbon fractions can be used for catalyst screening. A hydrogen consumption diagram used to provide a more significant selectivity test than the hyperbolic correlation is also included. (BLM)

1981-01-01

365

Materials testing and failure analysis activities at the Wilsonville Advanced Coal Liquefaction Research and Development Facility  

Science.gov (United States)

Oak Ridge National Laboratory (ORNL) has for over ten years provided materials testing and failure analysis services to various coal conversion and utilization facilities in the United States. ORNL was involved in these types of activities at all four of the major coal liquefaction pilot plants. This paper presents a summary of activities at Wilsonville over the past two and one-half years. Some details of these activities are discussed below. Failure analysis of elastomers, stainless steels, and alloys is discussed. 6 refs., 9 figs., 13 tabs.

1989-01-01

366

Ion exchange resins for water purification : properties and characterisation  

International Nuclear Information System (INIS)

The report is divided into three sections. The first section contains a general introduction to ion exchange resins used in various processes, the second section describes characteristic properties of the polymer materials and the inter relation between them. This will, in turn, be useful to interpret the data obtained from the various tests carried out on the resins in the laboratory. In the third section of the report, are given the details of each method used for a particular test to be carried out on a routine basis. Each method describes the principle involved, the reagents and apparatus used in the experiment, the actual procedure and calculations and recording of the data. 3 refs. (author).

2005-03-14

367

Investigation of Various Wind Turbine Drivetrain Condition Monitoring Techniques  

Energy Technology Data Exchange (ETDEWEB)

The wind industry has experienced premature turbine component failures during the past years. With the increase in turbine size, these failures, especially those found in the major drivetrain components, i.e. main shaft, gearbox, and generator, have become extremely costly. Given that the gearbox is the most costly component in the drivetrain to fix, the National Renewable Energy Laboratory (NREL) initiated the Gearbox Reliability Collaborative (GRC) to determine the causes for premature gearbox failures and subsequently, recommend improvements to gearbox design, manufacture, and operational practices. The GRC has two identical test gearboxes, which are planned for a dynamometer and a field test, respectively.

2010-08-01

368

Field validation of cable monitoring and rating system (CMARS) laboratory model. Semi-annual report, 1 May 1979-31 December 1979  

Energy Technology Data Exchange (ETDEWEB)

One year of research on validating the performance of the Cable Monitoring and Rating System (CMARS) is reported. The performance testing was conducted on underground 230-kV and 345-kV pipe type cable circuits owned by the New Jersey Public Service Electric and Gas Co. Laser temperature monitoring systems and a data acquisition system were installed. Software installation and development is discussed. The CMARS testing program is described. (LCL)

1980-01-01

369

Exploratory battery technology development and testing report for 1989  

Energy Technology Data Exchange (ETDEWEB)

Sandia National Laboratories, Albuquerque, has been designated as Lead Center for the Exploratory Battery Technology Development and Testing Project, which is sponsored by the US Department of Energy's Office of Energy Storage and Distribution. In this capacity, Sandia is responsible for the engineering development of advanced rechargeable batteries for both mobile and stationary energy storage applications. This report details the technical achievements realized in pursuit of the Lead Center's goals during calendar year 1989. 4 refs., 84 figs., 18 tabs.

1990-12-01

370

Application of the GEM shutdown device to the FFTF reactor  

Energy Technology Data Exchange (ETDEWEB)

A novel device called the gas expansion model (GEM) is being developed at the Hanford Engineering Development Laboratory for testing in the 400-MW(th) fast flux test facility (FFTF) reactor. Incorporation of the GEM into liquid-metal reactor designs is intended to measurably contribute to the achievement of inherent safety, by allowing the reactor to passively shut down even in the extremely remote (hypothetical) event of an unprotected (no scram) loss-of-flow accident. The purpose of this paper is to describe the GEM and present predictive analyses of the effectiveness of the device during unprotected loss-of-flow experiments in the FFTF.

1986-01-01

371

Application of the GEM shutdown device to the FFTF reactor  

International Nuclear Information System (INIS)

A novel device called the gas expansion model (GEM) is being developed at the Hanford Engineering Development Laboratory for testing in the 400-MW(th) fast flux test facility (FFTF) reactor. Incorporation of the GEM into liquid-metal reactor designs is intended to measurably contribute to the achievement of inherent safety, by allowing the reactor to passively shut down even in the extremely remote (hypothetical) event of an unprotected (no scram) loss-of-flow accident. The purpose of this paper is to describe the GEM and present predictive analyses of the effectiveness of the device during unprotected loss-of-flow experiments in the FFTF.

1986-11-16

372

A study on diagnostic techniques of pump operating condition  

Energy Technology Data Exchange (ETDEWEB)

The scope and contents investigate and reviewed are as follows : establishment of study plan and references survey, review of related problems and inservice test standards of safety injection pump in use nuclear power plant, review of the study results in laboratory, the theoretical investigation of temperature rise according to mini-flow rate of pump, mini-flow rate working characteristics of high and low pressure injection pumps at nuclear power plants, setup of testing equipment for measuring ampere, discharge pressure and vibration, selection and behaviors analysis of major parameters concerning pump degradation.

1998-03-15

373

Utility battery storage systems program report for FY 94  

Energy Technology Data Exchange (ETDEWEB)

Sandia National Laboratories, New Mexico, conducts the Utility Battery Storage Systems Program, which is sponsored by the US Department of Energy`s Office of Energy Management. The goal of this program is to assist industry in developing cost-effective battery systems as a utility resource option by 2000. Sandia is responsible for the engineering analyses, contracted development, and testing of rechargeable batteries and systems for utility energy storage applications. This report details the technical achievements realized during fiscal year 1994.

1995-03-01

374

Utility Battery Storage Systems Program report for FY93  

Energy Technology Data Exchange (ETDEWEB)

Sandia National Laboratories, New Mexico, conducts the Utility Battery Storage Systems Program, which is sponsored by the US Department of Energy`s Office of Energy Management. In this capacity, Sandia is responsible for the engineering analyses, contract development, and testing of rechargeable batteries and systems for utility-energy-storage applications. This report details the technical achievements realized during fiscal year 1993.

1994-02-01

375

Subcriticality calculations for the FFTF reverse approach to critical experiment  

Science.gov (United States)

The reverse approach to critical (RAC) experiments were performed in the ZPR-IX critical facility at Argonne National Laboratory. One of the major objectives of this project is to determine the adequacy of the low-level flux monitor (LLFM) detectors for initial loading of the Fast Flux Test Facility (FFTF). 5 references. (auth)

1975-01-01

376

Studies of the dissolution of geothermal scale  

Science.gov (United States)

Samples of geothermal scale formed from Magmamax No. 1 and Woolsey No. 1 wells in the Imperial Valley, Calif., were exposed to concentrated and dilute solutions of common laboratory reagents. The time of exposure and temperature of the reagent were also varied. Several reagents easily dissolved significant amounts of the scale. An in situ test was performed with marginal success.

1980-02-04

377

Studies of activated carbon and carbon black for supercapacitor applications  

Energy Technology Data Exchange (ETDEWEB)

Carbon Black and activated carbon materials providing high surface areas and a distinct pore distribution are prime materials for supercapacitor applications at frequencies < 0.5 Hz. A number of these materials were tested for their specific capacitance, surface and pore size distribution. High capacitance electrodes were manufactured on the laboratory scale with attention to ease of processability. (author) 1 fig., 1 ref.

1999-08-01

378

Research, development and demonstration of a fuel cell/battery powered bus system. Phase 1, Final report  

Energy Technology Data Exchange (ETDEWEB)

Purpose of the Phase I effort was to demonstrate feasibility of the fuel cell/battery system for powering a small bus (under 30 ft or 9 m) on an urban bus route. A brassboard powerplant was specified, designed, fabricated, and tested to demonstrate feasibility in the laboratory. The proof-of-concept bus, with a powerplant scaled up from the brassboard, will be demonstrated under Phase II.

1990-02-28

379

Performance estimates for attached-sunspace passive solar heated buildings  

Energy Technology Data Exchange (ETDEWEB)

Performance predictions have been made for attached-sunspace types of passively solar heated buildings. The predictions are based on hour-by-hour computer simulations using computer models developed in the framework of PASOLE, the Los Alamos Scientific Laboratory (LASL) passive solar energy simulation program. The models have been validated by detailed comparison with actual hourly temperature measurements taken in attached-sunspace test rooms at LASL.

1980-01-01

380

Multiple imaging radiography at LNLS  

Energy Technology Data Exchange (ETDEWEB)

An analyzer-based X-ray phase-contrast imaging (ABI) setup has been mounted at the Brazilian Synchrotron Light Laboratory (LNLS) for multiple imaging radiography (MIR) purposes. The algorithm employed for treating the MIR data collected at LNLS is described, and its reliability in extracting the distinct types of contrast that can be obtained with MIR is demonstrated by analyzing a test sample (thin polyamide wire). As a practical application, the possibility of studying ophthalmic tissues, corneal sequestra in this case, via MIR is investigated.

2008-01-11

381

Monthly Status Report for Systems & Application Support for National Cancer Institute Center for Bioinformatics & Laboratory of Population Genetics  

Science.gov (United States)

Assisted users with expired passwords Closed 233 NCICB Support Wizard Accounts Tickets Set up Resource Accounts for individual developers to control and track access on QA Application servers Maintained daily account synchronization between GForge project developers and CVS write access accounts Created FTP and SFTP user accounts for TCGA test, analysis datasets downloads and analysis datasets management.

382

Intercomparison of irradiance measurements based on WRR and ETL irradiance scales  

Energy Technology Data Exchange (ETDEWEB)

We report the corrected intercomparison of the World Radiometer Reference (WRR) irradiance scale and the Electrotechnical Laboratory (ETL) spectral irradiance scale. In addition, we confirm the intercomparison precision using the test facility where the irradiance of ETL 500 W standard lamp can be measured directly with the cavity radiometer. The results showed that the irradiance based on the WRR scale was 0.5-0.7% lower than the one based on the ETL scale

1997-10-14

383

Implementation and laboratory test results for an adaptive Power System Stabilizer based on linear optimal control  

Energy Technology Data Exchange (ETDEWEB)

Implementation of an adaptive power system stabilizer (PSS) based on linear optimal control is described in this paper. The generator is identified in real time, and a special 3rd order discrete Riccati equation is solved in each sample interval. Because the output of the generator is fed back directly, the controller can track the system very fast. Experimental studies on a physical model of a power system demonstrate the effectiveness of the proposed adaptive optimal controller.

1990-12-01

384

Energy storage systems program report for FY1996  

Energy Technology Data Exchange (ETDEWEB)

Sandia National Laboratories, New Mexico, conducts the Energy Storage Systems Program, which is sponsored by the US Department of Energy`s Office of Utility Technologies. The goal of this program is to assist industry in developing cost-effective energy storage systems as a resource option by 2000. Sandia is responsible for the engineering analyses, contracted development, and testing of energy storage systems for stationary applications. This report details the technical achievements realized during fiscal year 1996.

1997-05-01

385

DECOVALEX - Mathematical models of coupled T-H-M processes for nuclear waste repositories. Report of phase III  

Energy Technology Data Exchange (ETDEWEB)

This report presents the methodologies and results of the field/laboratory experiments and mathematical modeling defined for the phase III of the project. Results from test cases 2-6 are given in separate chapters of the report (which have been indexed separately), and the last chapter discusses the lessons learned from the three phases of the DECOVALEX project.

1995-12-01

386

Automated remote positioning and examination of FFTF reactor power characterization dosimeters  

Energy Technology Data Exchange (ETDEWEB)

The Fast Flux Test Facility (FFTF) reactor characterization by the Hanford Engineering Development Laboratory (HEDL) includes extensive neutronic measurements during startup and initial operation. To aid in the handling and counting of the thousands of passive dosimeters used as part of this effort, an automated dosimetry specimen handling, positioning, and counting system was designed and developed by Westinghouse Hanford for the Department of Energy.

1981-05-04

387

Stress corrosion cracking of 13% Cr martensitic steels in sodium chloride solutions in the presence of thiosulphate  

Energy Technology Data Exchange (ETDEWEB)

The stress corrosion cracking (SCC) susceptibility of 13% Cr martensitic (UNS S42000) and supermartensitic (UNS S41125) steels in sodium chloride solutions in the presence of thiosulphate was evaluated by slow strain rate tests (SSRT). The tests were performed in 5% sodium chloride solutions buffered at pH 2.7, 3.5, 4.5 and 6.0 in the absence and presence of thiosulphate in a concentration range between 10{sup -6} and 10{sup -3} M, at 25 {+-} 0.1 C. The electrochemical behaviour of the two steels in the different solutions was determined by recording the anodic and cathodic polarisation curves. 13% Cr martensitic steel showed SCC in 5% sodium chloride solutions with pH {<=} 4.5 in the presence of 3 x 10{sup -6} thiosulphate. Decreasing the chloride ion concentration from 50 to 10 g/l, the critical concentration of thiosulphate to provoke SCC susceptibility increased from 3 x 10{sup -6} to 1 x 10{sup -5} M. The ...

2000-04-01

388

Development of materials resistant to metal dusting degradation.  

Energy Technology Data Exchange (ETDEWEB)

Metal dusting corrosion has been a serious problem in the petroleum and petrochemical industries, such as reforming and syngas production systems. This form of deterioration has led to worldwide material loss for 50 years. For the past three years, we have studied the mechanism of metal dusting for Fe- and Ni-base alloys. In this report, we present a correlation between the weight loss and depth of pits that form in Ni-base alloys. Nickel-base alloys were also tested at 1 and 14.8 atm (210 psi), in a high carbon activity environment. Higher system pressure was found to accelerate corrosion in most Ni-base alloys. To reduce testing time, a pre-pitting method was developed. Mechanical scratches on the alloy surface led to fast metal dusting corrosion. We have also developed preliminary data on the performance of weldments of several Ni-base alloys in a metal dusting environment. ...

2006-04-24

389

Pitting corrosion of nickel base alloys in halide media  

International Nuclear Information System (INIS)

A computerized corrosion measuring system (EG and G model 350 A) was used to study the influence of Cr, Mo, Ti, Nb and W on the pitting corrosion of nickel base alloys in 3% NaCl at 90"0C. The electrochemical parameters under investigation are the corrosion potential E_c_o_r_r, pitting potential E_p and protection potential E_p_p. The corrosion behaviour of nickel base alloys were studied by using pitting scan and potentiostatic techniques. Values of corrosion potential, pitting potential and protection potential were used for a ranking of alloys for corrosion resistance.

1988-03-06

390

Surface improvement and biocompatibility of TiAl{sub 24}Nb{sub 10} intermetallic alloy using rf plasma nitriding  

Energy Technology Data Exchange (ETDEWEB)

The present work describes the surface improvement and biocompatibility of TiAl{sub 24}Nb{sub 10} intermetallic alloy using rf plasma nitriding. The nitriding process was carried out at different plasma power from 400 W to 650 W where the other plasma conditions were fixed. Grazing incidence X-ray diffractometry (GIXRD), Auger electron spectroscopy (AES), tribometer and a nanohardness tester were employed to characterize the nitrided layer. Further potentiodynamic polarization method was used to describe the corrosion behavior of the un-nitrided and nitrided alloy. It has been found that the Vickers hardness (HV) and corrosion resistance values of the nitrided layers increase with increasing plasma power while the wear rates of the nitrided layers reduce by two orders of magnitude as compared to those of the un-nitrided layer. This improvement in surface properties of the intermetallic alloy is due to formation of a thin modified layer which is ...

2007-09-30

391

Surface improvement and biocompatibility of TiAl_2_4Nb_1_0 intermetallic alloy using rf plasma nitriding  

International Nuclear Information System (INIS)

The present work describes the surface improvement and biocompatibility of TiAl_2_4Nb_1_0 intermetallic alloy using rf plasma nitriding. The nitriding process was carried out at different plasma power from 400 W to 650 W where the other plasma conditions were fixed. Grazing incidence X-ray diffractometry (GIXRD), Auger electron spectroscopy (AES), tribometer and a nanohardness tester were employed to characterize the nitrided layer. Further potentiodynamic polarization method was used to describe the corrosion behavior of the un-nitrided and nitrided alloy. It has been found that the Vickers hardness (HV) and corrosion resistance values of the nitrided layers increase with increasing plasma power while the wear rates of the nitrided layers reduce by two orders of magnitude as compared to those of the un-nitrided layer. This improvement in surface properties of the intermetallic alloy is due to formation of a thin modified layer which is ...

2007-09-30

392

Preliminary Thermo-Hydraulic Analysis of Sulfuric Acid Loop for NHDD System  

International Nuclear Information System (INIS)

Very High Temperature gas cooled nuclear Reactor (VHTR), which was coupled with Sulfur-Iodine (SI) thermo-chemical cycle, has been selected for the Nuclear Hydrogen Development and Demonstration (NHDD) project in Korea Atomic Energy Research Institute. Among the various hydrogen production methods, Sulfur-Iodine (SI) thermo-chemical cycle is a good method as a massive hydrogen production without CO2 emission. In SI cycle, the sulfuric acid decomposition is one issue for the material corrosion on high temperature and pressure condition. For the simulation of the sulfuric acid decomposition, we designed a sulfuric acid loop with a small-scale gas loop which is simulated for the integrity and feasibility tests on a H2SO4 decomposition process. The primary objective of the loop is to validate the corrosion and the mechanical performances of a key component of the NHDD, Process Heat Exchanger (PHE). In this paper, we discussed ...

2010-10-01

393

Irradiation-assisted stress corrosion cracking of HTH Alloy X-750 and Alloy 625  

International Nuclear Information System (INIS)

In-reactor testing of bolt-loaded compact tension specimens was performed in 360 C water. New data confirms previous results that high irradiation levels reduce SCC resistance in Alloy X-750. Low boron heats show improved IASCC (irradiation-assisted stress corrosion cracking). Alloy 625 is resistant to IASCC. Microstructural, microchemical, and deformation studies were carried out. Irradiation of X-750 caused significant strengthening and ductility loss associated with formation of cavities and dislocation loops. High irradiation did not cause segregation in X-750. Irradiation of 625 resulted in formation of small dislocation loops and a fine body-centered-orthorhombic phase. The strengthening due to loops and precipitates was apparently offset in 625 by partial dissolution of #gamma# precipitates. Transmutation of boron to helium at grain boundaries, coupled with matrix strengthening, is believed to be responsible for IASCC in X-750, and the ...

1995-08-06

394

Iron Aluminide Hot Gas Filters  

Energy Technology Data Exchange (ETDEWEB)

Currently, high temperature filter systems are in the demonstration phase with the first commercial scale hot filter systems being installed on integrated gasification combined cycle (IGCC) and pressurized fluid bed combustion cycle (PBFC) systems (70 MW). They are dependent on the development of durable and economic high temperature filter systems. These filters are mostly ceramic tubes or candles. Ceramic filter durability has not been high. Failure is usually attributed to mechanical or thermal shock: they can also undergo significant changes due to service conditions. The overall objective of this project is to commercialize weldable, crack resistant filters which will provide several years service in advanced power processes. The specific objectives of this project are to develop corrosion resistant alloys and manufacturing processes to make Iron Aluminide filter media, and to use a ``short term`` exposure apparatus supported by other ...

1996-12-31

395

Influence of bias voltage on the formation and properties of iron-based nitrides produced by plasma nitriding  

Energy Technology Data Exchange (ETDEWEB)

A series of experiments have been conducted on AISI 5140 low alloy steel using a hollow cathode discharge-assisted plasma nitriding apparatus with the aim of elucidating the role of substrate bias voltages in plasma nitriding process. For comparison, some samples were nitrided with applied substrate bias (-50 V) while other samples were nitrided at floating potential. Treatments were carried out in NH{sub 3} atmosphere of 150 Pa at temperatures ranging from 450 {sup o}C to 550 {sup o}C for 2 h, 4 h, and 6 h. The nitrided samples were characterized by optical microscopy, X-ray diffraction and micro-hardness measurement. The corrosion behaviors were evaluated using anodic polarization tests in 3.5% NaCl solution. The results showed that the microstructure and phase constituents of the nitride layers were strongly influenced by the bias voltages. It was also demonstrated that the better corrosion resistance with a thicker ...

2010-05-14

396

Influence of bias voltage on the formation and properties of iron-based nitrides produced by plasma nitriding  

International Nuclear Information System (INIS)

A series of experiments have been conducted on AISI 5140 low alloy steel using a hollow cathode discharge-assisted plasma nitriding apparatus with the aim of elucidating the role of substrate bias voltages in plasma nitriding process. For comparison, some samples were nitrided with applied substrate bias (-50 V) while other samples were nitrided at floating potential. Treatments were carried out in NH_3 atmosphere of 150 Pa at temperatures ranging from 450 "oC to 550 "oC for 2 h, 4 h, and 6 h. The nitrided samples were characterized by optical microscopy, X-ray diffraction and micro-hardness measurement. The corrosion behaviors were evaluated using anodic polarization tests in 3.5% NaCl solution. The results showed that the microstructure and phase constituents of the nitride layers were strongly influenced by the bias voltages. It was also demonstrated that the better corrosion resistance with a thicker nitrided layer was ...

2010-05-14

397

Growth of Cr-Nitrides on commercial Ni-Cr and Fe-Cr base alloys to protect PEMFC bipolar plates  

Energy Technology Data Exchange (ETDEWEB)

Nitridation of Cr-bearing alloys can yield low interfacial contact resistance (ICR), electrically conductive and corrosion-resistant CrN or Cr{sub 2}N base surfaces of interest for a range of electrochemical devices, including fuel cells, batteries, and sensors. This paper presents results of exploratory studies of the nitridation of commercially available, high Cr (30-35 wt%) Ni-Cr alloys and a ferritic high Cr (29 wt%) stainless steel for proton exchange membrane fuel cell (PEMFC) bipolar plates. A high degree of corrosion resistance in sulfuric acid solutions designed to simulate bipolar plate conditions and low ICR values were achieved. Oxygen impurities in the nitriding environment were observed to play a significant role in the nitrided surface structures that formed, with detrimental effects for the Ni-Cr base alloys, but beneficial effects for the stainless steel alloy. Positive results from single-cell fuel cell ...

2007-11-15

398

Growth of Cr-Nitrides on Commercial Ni-Cr and Fe-Cr Base Alloys to Protect PEMFC Bipolar Plates  

Energy Technology Data Exchange (ETDEWEB)

Nitridation of Cr-bearing alloys can yield low interfacial contact resistance (ICR), electrically- conductive and corrosion-resistant CrN or Cr2N base surfaces of interest for a range of electrochemical devices, including fuel cells, batteries, and sensors. This paper presents results of exploratory studies of the nitridation of two high Cr (30-35 wt%) commercially available Ni-Cr alloys and a ferritic high Cr (29 wt.%) stainless steel for proton exchange membrane fuel cell (PEMFC) bipolar plates. A high degree of corrosion resistance in sulfuric acid solutions designed to simulate bipolar plate conditions and low ICR values were achieved via nitridation. Oxygen impurities in the nitriding environment were observed to play a significant role in the nitrided surface structures that formed, with detrimental effects for the Ni-Cr base alloys, but beneficial effects for the stainless steel alloy. Results of single-cell fuel cell ...

2007-01-01

399

Fatigue crack growth in steam turbine rotor steels in near realistic media  

International Nuclear Information System (INIS)

In this study, growth measurements of fatigue cracks in air and various simulated media for steam turbines were made by means of rupture-mechanical methods. In this connection, it was detected that even pure water leads to a clear increase in the fatigue crack rates of low-pressure rotor steels. In this connection, it was striking to observe that the crack propagation velocities at 100"0C were higher than at 160"0C. It is probable that the kinetics of the film formation at the crack tip was of importance. The inhibiting effect of the alkaline solutions is explained by the increasing stability of a film of Fe(OH)_2 at an increased pH value. Neither the frequency response nor the fractographic result indicate an influence of the stress crack corrosion. This can be explained by the fact that the incubation period (= the period to initiate an intercrystalline crack caused by stress crack corrosion at a transcrystalline fatigue crack tip) in the ...

1988-03-17

400

Enhanced defect detection and sizing accuracy using matrix phased array ultrasonic tools  

Energy Technology Data Exchange (ETDEWEB)

Although ultrasonic testing inspection technology and tools have improved significantly, there is still a need for more reliable detection, monitoring, and accurate sizing of crack-like and planar defects, complex corrosion damage, and detection of secondary features within deformed pipe. Ultrasonic two dimensional (2D) matrix phased array technology offers some unique advantages that make the technology promising for improving detection and sizing of pipeline flaws resulting from welding or from in-service damage. Ultrasonic modeling and simulation has been conducted to evaluate the detection and sizing capabilities of 2D matrix arrays for various pipeline inspection concepts. Simulations have been performed using both flexible and rigid array probes. Inspection concepts using rigid probes were evaluated for inspections from both the outside and inside pipe surfaces, while flexible probes were evaluated primarily for inspection from the ...

2009-07-01

401

Anti-corrosive properties of an electropolymerized polymer coating on a shape memory alloy surface  

Energy Technology Data Exchange (ETDEWEB)

Acrylonitrile electropolymerization (in an aprotic and anhydrous medium) has been used as a way to build thin, homogeneous and covering polyacrylonitrile layers grafted on the surface of usual metals and specially on copper-based shape memory alloy: Cu-Zn-Al. The results of the study first confirm the possibility of grafting thin and covering polyacrylonitrile layers on Cu-Zn-Al surface. The morphology of the films however is influenced by the geometry of the polycristalline structure of the alloy and its superficial defects. Samples obtained after grafting polyacrylonitrile films were submitted to corrosion tests based on Electrochemical Impedance Spectroscopy (EIS) measurements in a NaCl/H{sub 2}O medium. Results show that some post-treatments of the grafted films are necessary to improve their protective role, while preserving the strong interfacial bondings. Actually, thermal and mechanical cycling of the shape memory alloy covered by ...

1996-01-01

402

University of Central Lancashire - Facilities  

Wastenet

...specialised laboratories for pharmaceutics, tissue culture and molecular biology Excellent Laboratory Facilities Tissue Culture Facilities Molecular Biology Laboratory ...

403

Corrosion problems and resistance to corrosion of materials for production of steam generators for light water reactor power plants. [Alloys I-600, I-800, I-690  

Energy Technology Data Exchange (ETDEWEB)

Briefly described is knowledge of crevice corrosion, corrosion cracking and denting. In evaluating the corrosion resistance of steam generator materials it is necessary to distinguish corrosion problems caused by the primary coolant side and by the secondary circuit side. At present tubes are manufactured of 7 austenitic alloys of a different chemical composition, and available information shows that views on their corrosion resistance differ. Greatest attention has been devoted to corrosion cracking in the presence of NaOH. Findings related to I-600, I-800, I-690 and AISI 316 are given. Corrodibility by sulfur-containing products is now being studied, namely the intercrystalline corrosion cracking caused by the presence of H/sub 2/S/sub 4/O/sub 6/. Knowledge gained in this respect is summed up.

1984-07-01

404

Corrosion problems and resistance to corrosion of materials for production of steam generators for li.ght water reactor power plants  

International Nuclear Information System (INIS)

Briefly described is knowledge of crevice corrosion, corrosion cracking and denting. In evaluating the corrosion resistance of steam generator materials it is necessary to distinguish corrosion problems caused by the primary coolant eide and by the secondary circuit side. At present tubes are manufactured of 7 austenitic alloys of a different chemical composition, and available information shows that views on their corrosion resistance differ. Greatest attention has been devoted to corrosion cracking in the presence of HaOH. Findings related to I-600, I-800, I-690 and AISI 316 are given. Corrodibility by sulfur-containing products is now being studied, namely the intercrystalline corrosion cracking caused by the presence of H_2S_4O_6. Knowledge gained in this respect is summed up. (J.P.).

405

Corrosion in steam generators of PWR type nuclear power plants  

International Nuclear Information System (INIS)

Problems are discussed of heat exchange tubes of Westinghouse type vertical steam generators exhibiting corrosion damage such as point corrosion, planar corrosion, tube denting, corrosion stress cracking, crevice corrosion, fretting corrosion and intergranular corrosion. Attention is also paid to problems of WWER-440 type horizontal steam generators, where the level fluctuation area is critical; noncompact porous deposits of the corrosion products give rise to crevice effects and cause significant concentration of chloride ions and other additions. This problem can be partly resolved by a modification of the collector design at the level variation area. An additional measure is the production of steel 08Kh18N10T with a very low level of harmful elements and inclusions. (Z.M.). 3 figs., 11 refs.

1988-03-01

406

Thermogalvanic effects on the pitting corrosion of water-cooled heat exchangers  

Energy Technology Data Exchange (ETDEWEB)

Thermogalvanic corrosion of St3 steel in a temperature range from 25 to 50{degrees}C with a 3.84{degrees}C/cm gradient was studied in a neutral media flow. It is shown that the thermogalvanic effect on the pitting corrosion of water-cooled heat exchangers is decisive but dual. Depending on the composition of the cooling medium, thermogalvanic corrosion may either enhance (0.5 M NaCl) or inhibit (tap water) pitting corrosion.

1995-05-01

407

Improvement of PWR reliability by corrosion prevention  

Energy Technology Data Exchange (ETDEWEB)

Since first PWR in Japan started commercial operation in 1970, we have encountered the various modes of corrosion on primary and secondary side components. We have paid much efforts for resolving these corrosion problems, that is, investigating the causes of corrosion and establishing the countermeasures for these corrosion. We summarize these efforts in this article. (author)

1999-12-01

408

Hydrodynamic measurement of a single corrosion pit  

Energy Technology Data Exchange (ETDEWEB)

The hydrodynamics of gas evolution plays an important role in the pitting corrosion of metals. A new technique for the measurement of the local hydrodynamics caused by corrosion processes, using the atomic force microscope, has been presented in this work. The hydrodynamics of hydrogen evolution on Al surface due to pitting corrosion was studied. The characteristic features of the hydrodynamics are discussed. To the best of our knowledge this is the first local measurement of pitting corrosion hydrodynamics.

2004-11-01

409

Radioxenons: Their role in monitoring a Comprehensive Test Ban Treaty  

Energy Technology Data Exchange (ETDEWEB)

Monitoring for xenon radionuclides which are produced in a nuclear detonation can provide a strong deterrent to the violation of a Comprehensive nuclear Test Ban Treaty (CTBT). There are 18 known radioactive xenon isotopes produced in nuclear fission with half-lives ranging from less than one second to 11.9 days. However, only four of these remain in significant amounts more than a day after a detonation. In order for radioxenon monitoring to be practical, it was necessary to develop an automated measurement system which could operate unattended for periods of months, measure the entire spectrum of radioxenons, and provide hundreds of times better sensitivities than current laboratory procedures. This capability was developed at the US Department of Energy`s Pacific Northwest National Laboratory based on rapid separation of atmospheric xenon coupled with a unique high sensitivity measurement device for the radioxenons. A ...

1996-06-01

410

European multicentre evaluation of the Super Aution SA-4220 urinalysis analyser.  

Science.gov (United States)

A multicentre evaluation of the urine test strip analyser Super Aution-4220 was carried out in six laboratories. The analytical performance of the instrument with regard to imprecision, linearity, detection limit, drift, carry-over and method comparison was studied. Using the Aution stick 8 test strip the pH, glucose, protein, ketones, bilirubin, blood, urobilinogen and leukocyte esterase were analysed. Specific gravity measurements were performed by refractive index method. Within-run and between-run imprecision determined at three levels of analyte were good. No carry-over was observed. Obtained results were linear through all the described analytical range. No significant drift was detected. Method comparison with some quantitative methods was performed and showed a good correlation with most of the analytes. The study of interferences showed minor interferences by common therapeutic drugs with the measurement of some ...

1998-12-01

411

Assessment of asymptomatic liver fibrosis in alcoholic patients using fibroscan: prospective comparison with seven non-invasive laboratory tests  

British Library Electronic Table of Contents (United Kingdom)

Summary Background Systematic screening for liver fibrosis in heavy-drinking patients is a challenge. Aims To assess Fibroscan for non-invasive diagnosis of asymptomatic liver fibrosis in alcohol abuse patients, to determine diagnostic liver stiffness cut-off values and to compare performance of Fibroscan with seven non-invasive laboratory tests. Methods One hundred and three alcoholic patients were studied. Liver fibrosis was staged by METAVIR system. Fibroscan, Fibrotest, Fibrometer, Hepascore, APRI, PGA, PGAA and hyaluronic acid tests were performed. Liver stiffness cut-offs were determined using receiver-operating characteristic (ROC) curves. Results Liver stiffness was correlated with fibrosis (r = 0.72, P < 0.014), with median at 5.7, 6.3, 8.4, 15 and 47.3 kPa for F0 (n = 8), F1 (n =...

2008-01-01

412

Sensor test facilities and capabilities at the Nevada Test Site  

Energy Technology Data Exchange (ETDEWEB)

Sandia National Laboratories has recently developed two major field test capabilities for unattended ground sensor systems at the Department of energy`s Nevada Test Site (NTS). The first capability utilizes the NTS large area, varied terrain, and intrasite communications systems for testing sensors for detecting and tracking vehicular traffic. Sensor and ground truth data can be collected at either of two secure control centers. This system also includes an automated ground truth capability that consists of differential Global Positioning Satellite (GPS) receivers on test vehicles and live TV coverage of critical road sections. Finally there is a high-speed, secure computer network link between the control centers and the Air Force`s Theater Air Command and Control Simulation Facility in Albuquerque NM. The second capability is Bunker 2-300. It is a facility for evaluating advanced ...

1996-12-31

413

Graphite electrode arc melter demonstration Phase 2 test results  

Energy Technology Data Exchange (ETDEWEB)

Several U.S. Department of Energy organizations and the U.S. Bureau of Mines have been collaboratively conducting mixed waste treatment process demonstration testing on the near full-scale graphite electrode submerged arc melter system at the Bureau`s Albany (Oregon) Research Center. An initial test series successfully demonstrated arc melter capability for treating surrogate incinerator ash of buried mixed wastes with soil. The conceptual treatment process for that test series assumed that buried waste would be retrieved and incinerated, and that the incinerator ash would be vitrified in an arc melter. This report presents results from a recently completed second series of tests, undertaken to determine the ability of the arc melter system to stably process a wide range of {open_quotes}as-received{close_quotes} heterogeneous solid mixed wastes containing high levels of organics, representative of the ...

1996-06-01

414

Effect of low-proof alcohol fumigation-fueling on crankcase oil dilution in a diesel-cycle engine. Final report  

Energy Technology Data Exchange (ETDEWEB)

An Allis-Chalmers, Model 2900, turbocharged diesel engine was converted to a dual-fuel engine in which ethyl alcohol was fumigated between the turbocharger and the intake manifold, and the diesel fuel was injected normally at a reduced rate. Tests were performed to determine if crankcase oil dilution that had occurred was caused by the following independent parameters: proof of the ethyl alcohol, crankcase oil temperature, engine load at maximum torque speed, and percentage of total energy in the form of ethyl alcohol. Engine tests were steady state for six hours, after which the crankcase oil was sampled for American Society for Testing and Materials (ASTM) laboratory tests for determination of flash points and fire points, water by centrifuge, water by distillation, and viscosity at room temperature. Results indicate a decrease in thermal efficiency and an increase in exhaust ...

1982-11-01

415

Bioremediation process in impacted area of petroleum activities; Processos de biorremediacao em areas influenciadas por atividades petroliferas  

Energy Technology Data Exchange (ETDEWEB)

The present work's objective is to test sampling methodologies applied on the bioremediation processes in situ, involving the establishment of sample replicates, specific laboratory procedures and its results, inedited on the referred technique. Agricultural fertilizers were used, NPK and OSMOCOTE, as biostimulants on mangroves substrates affected by petroleum activities. The tested methodology used on the experiment was based on the monitoring of this technology in aquarium with water from Sao Paulo's river and sediment contaminated by oil, realized in three steps (first pre-test, second pre-test and third pre-test) that happened between the months of August and November of 2007. The physical-chemical parameters were measured with portable devices carefully calibrated and the oil analyzed with gas chromatography. The saturated hydrocarbons ...

2008-07-01

416

Corrosion behaviour of non-ferrous metals in sea water  

Energy Technology Data Exchange (ETDEWEB)

The most typical kinds of corrosion of brasses are selective corrosion (dezincification) and stress corrosion. Prevention against these kinds of corrosion lies in application of arsenic alloy addition and appropriate heat treatment removing internal stresses as well as in maintaining the arsenic and phosphorus contents on a proper level. The most typical corrosion of cupronickels is the local corrosion. Selective corrosion occurs less often and corrosion cracking caused by stress corrosion in sea water does not usually occur. Crevice corrosion is found especially in places of an heterogeneous oxidation of the surface under inorganic deposits or under bio-film. Common corrosive phenomena for brasses and cupronickels are the effects caused by sea water flow and ...

2004-07-01

420

Tank 241-AZ-101 Mixer Pump Test Vapor Sampling and Analysis Plan  

Energy Technology Data Exchange (ETDEWEB)

This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained during the operation of mixer pumps in tank 241-AZ-101. The primary purpose of the mixer pump test (MPT) is to demonstrate that the two 300 horsepower mixer pumps installed in tank 241-AZ-101 can mobilize the settled sludge so that it can be retrieved for treatment and vitrification. Sampling will be performed in accordance with Tank 241-AZ-101 Mixer Pump Test Data Quality Objective (Banning 1999) and Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis (Mulkey 1999). The sampling will verify if current air emission estimates used in the permit application are correct and provide information for future air permit applications.

2000-04-10

421

New Permeameters for In Situ Characterization of Unsaturated Heterogeneous Permeability: Development, Design, Testing, and Application  

Energy Technology Data Exchange (ETDEWEB)

The original objective of our EMSP research was to design, develop, and test new in situ field permeameters for use in spatial variability studies of unsaturated hydraulic properties. We initially focused on activities related to development and testing of techniques for inverting permeameter data, development of numerical tools for data inversion, error evaluation for permeameter design, and permeameter component design. However, the results of error evaluations for permeameter design caused us to redirect our research, and reformulate our research objectives. We discovered that small, simple measurement errors lead to significant bias in the estimated hydraulic properties and their spatial statistics. Our reformulated research objective became the evaluation of the origin, impact and relevance of spatial bias in field-and laboratory-estimated unsaturate hydraulic properties, with an emphasis on spatial statistics and the ...

2001-12-01

422

Instrumented model pile tests on sand plugs  

Energy Technology Data Exchange (ETDEWEB)

0pen ended piles develop internal frictional resistance between the internal soil plug end the pile wall during axial loading. Current pipe pile design practice assumes that the ultimate internal skin friction is of the same order of magnitude as the outer skin friction. This paper describes a series of laboratory pile load tests on instrumented model pipe piles, designed to investigate the development of plug stresses and skin friction along the plug length during pile loading. The piles contain sand columns of various relative densities and of different heights. The soil plugs are loaded to failure under fully drained conditions. The test data indicate that internal skin friction in sand can be substantially higher than assumed in conventional design practice. This finding could lead to significant economical savings on future pipe pile foundations in sand.

1995-12-31

423

Electronics Personal Dosemeter (EPD-N) Test and Evaluation Report  

Energy Technology Data Exchange (ETDEWEB)

Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization then used at another site.

2003-04-08

424

Adaptation of an air-dielectric RF cable for use as an oil-filled high voltage pulse transmission line  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the specifications, conceptual design, prototype testing and operating experience of an oil-filled high voltage pulse transmission cable adapted from commercially available air-dielectric RF components. Lawrence Livermore National Laboratory's Advanced Test Accelerator (ATA) requires a method of transmitting 250kV, 70 nanosecond pulses from the power conditioning equipment to the accelerator. The oil-filled cable approach was chosen over alternative concepts because of its high voltage holding capacity, long life and flexibility. The criteria for cable and connector design are discussed. The results of prototype testing and performance of the final design are presented.

1984-11-01

425

A survey of point of care testing in Irish hospitals: room for improvement  

British Library Electronic Table of Contents (United Kingdom)

Background ?Guidelines for safe and effective management and use of point of care testing? have been recently launched in Ireland. Aims To survey point of care testing (POCT) services in the Republic of Ireland. Methods A questionnaire covering accreditation status, existence of POCT committees, quality management systems, and staff resources was distributed by the Irish External Quality Assessment Scheme (IEQAS). Results Of those that returned completed questionnaires, 56% had assigned specific POCT responsibilities to designated staff. Most support was for blood gases and glucose analysis. Compared with other published studies, Irish laboratories gave similar support for blood gases, less for glucose and much less for urinalysis. Conclusions This survey demonstrated poor IT support for P...

2011-01-01

426

Technology evaluation report for the Buried Waste Robotics Program Subsurface Mapping Project  

International Nuclear Information System (INIS)

This document presents a summary of the work performed in support of the Buried Waste Robotics Program Subsurface Mapping Project. The project objective was to demonstrate the feasibility of remotely characterizing buried waste sites. To fulfill this objective, a remotely-operated vehicle, equipped with several sensors, was deployed at the Idaho National Engineering Laboratory. Descriptions of the equipment and areas involved in the project are included in this report. Additionally, this document provides data that was obtained during characterization operations at the Cold Test Pit and the Subsurface Disposal Area, both at the Idaho National Engineering Laboratory's Radioactive Waste Management Complex, and at the Idaho Chemical Processing Plant. The knowledge gained from the experience, that can be applied to the next generation remote-characterization system, is extensive and is presented in this report.

427

A network security case study; The Los Alamos National Laboratory integrated computer network  

Energy Technology Data Exchange (ETDEWEB)

This paper reports on a study to validate the Graphical Network Representation (GRPHREP) model which is being conducted on the Los Alamos National Laboratory Integrated Computer Network (ICN). The GRPHREP model is a software system application based on graph theory and object-oriented programming methodologies. It codified the Department of Energy (DOE) Order 5637.1, which is concerned with classified computer secret policy, restrictions, and requirements. The Los Alamos ICN is required to control access to and support large-scale scientific and administrative computing. Thus, large-scale scientific and administrative computing. Thus we felt that this large, complex, and dynamic network would provide a good test for the graphical and functional capabilities of the model. Furthermore, the ICN is composed of multiple partitions that reflect the sensitivity and classification of the computation (data) and designate the required clearance level for ...

1991-01-01

428

S-N curves for welded tubular joints  

Energy Technology Data Exchange (ETDEWEB)

The objective of the project was to develop a welded tubular joint database to assess the fatigue design curves (X and X{prime}) in the American Petroleum Institute design code (API RP2A). Changes in the curve-fitting method and screening criteria (primarily the exclusion of the very thin tubular joints) produced results different from those reported previously. The current results show that the X and X{prime} curves are too conservative and that a new curve should be adopted. The Department of Energy T{prime} curve was found to be consistent with the screened tubular joint air data and is recommended for use in API RP2A. The weldment size effect exponent (n) of 0.25 in the current version of API RP2A was found to be too small, and a higher value of 0.30 consistent with the Department of Energy recommendations is recommended. The fatigue test results for tubular joints tested in air and tubular joints tested in sea water ...

1995-12-31

429

Final report on low-cycle fatigue and creep-fatigue testing of salt-filled alloy 800 specimens  

Energy Technology Data Exchange (ETDEWEB)

Uniaxial low-cycle fatigue and creep-fatigue tests have been carried out on hollow alloy 800 specimens that were either filled with air or with a molten mixture of sodium nitrate, potassium nitrate and an oxidizer. Low-cycle fatigue tests were carried out at 1200/sup 0/F and 650/sup 0/F by cycling the strain continuously between equal mangitude of tensile and compressive values at a rate of 4 x 10/sup -3/sec/sup -1/ until failure. The creep-fatigue tests were carried out at 1200/sup 0/F. The loading cycle differed from that of low-cycle fatigue testing only in the imposition of a hold at the peak compressive strain in each cycle. Cracks always initiated on the inner surface of the hollow specimen, and therefore, corrosive effects on crack propagation and initiation were controlled by the environment within the specimen cavity. In common with tests carried out ...

1982-05-01

430

Validating eddy current array probes for inspecting steam generator tubes  

International Nuclear Information System (INIS)

A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques and procedures. Methods are presented for calculating POD curves based on ...

1997-11-16

431

Validating eddy current array probes for inspecting steam generator tubes  

Energy Technology Data Exchange (ETDEWEB)

A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques and procedures. Methods are presented for calculating POD curves based on ...

1997-07-01

432

Production of ultra high strength steels by turbulent water cooling equipment (TWICE); Production d'aciers haute resistance par un dispositif de refroidissement a turbulence controlee  

Energy Technology Data Exchange (ETDEWEB)

A new industrial process allowing to reach very high cooling rates in the cooling section after soaking of a continuous annealing line for steel sheets is presented. This process constitutes the successful conclusion of a long term research programme, jointly carried out at CRM and Arcelor Cockerill-Sambre for three years, including laboratory experiments, pilot scale trials and several industrial campaigns. It is running on from developments performed in the framework of the HOWAQ (Hot Water Quench) process. The process successively combines a moderate cooling step (600 deg C/s for 0.8 mm thick strips), in boiling water, and a faster cooling step (above 700 deg C/s), by impinging turbulent cold water in a box. Its main features are simplicity, resulting from advanced developments, soundness, flexibility and cooling homogeneity. As treated steel products are characterized by improved mechanical properties, outstanding surface quality (corrosion ...

2003-08-01

433

Materials performance at the Wilsonville Coal Liquefaction Facility, 1989--1991  

Science.gov (United States)

The Advanced Coal Liquefaction Research and Development Facility in Wilsonville, Alabama, is funded by the US Department of Energy (DOE), the Electric Power Research Institute (EPRI), and Amoco Corporation. On behalf of these organizations, Southern Company Services manages and Southern Clean Fuels Division of Southern Electric International operates the Wilsonville facility. Oak Ridge National Laboratory (ORNL) receives funding from DOE to provide materials technical support to the Wilsonville operators. For the period July 1987 through November 1990 the plant was operated with two reactors a thermal reactor and a catalytic reactor in a close-coupled integrated two-stage liquefaction mode. Coal processed was obtained from several seams including Ohio No. 6, Illinois No. 6, and Pittsburgh No. 8, as well as Texas lignite and several subbituminous coals. Corrosion samples which were removed for examination at the end of this period were exposed ...

1991-01-01

434

Evaluation of value for hydrogen release from high-level liquid waste. 4. Hydrogen release rate for {gamma}-ray radiolysis of simulated purex waste solutions  

Energy Technology Data Exchange (ETDEWEB)

The rates of hydrogen release from simulated high-level liquid waste (SHLLW) during irradiation of {sup 60}Co {gamma}-rays have been studied using a laboratory-scale apparatus. The SHLLW used was made up of 28 different metal elements, the concentrations of which were determined from a computed data (ORIGEN-2) for a Purex spent fuel (burn-up of 4.5 GWd/t, cooling time of 4 years) except for those of corrosion products (Fe, Cr and Ni) and of chemical process additive (P). The nitrate ion concentration of the SHLLW was 4.97 M. The G-value of hydrogen release was 0.0164 for stirred conditions, but for nonstirred conditions with dose rate : 2.8 kGy/h and with the SHLLW solution height more than 8 cm, the following relation was found between the G-value and the solution height (d cm); G(H{sub 2}) = 0.100 d{sup -1.6}. The G-values of oxygen and nitrogen releases were also determined. (author)

1997-12-01

435

Evaluation of value for hydrogen release from high-level liquid waste. 4. Hydrogen release rate for #gamma#-ray radiolysis of simulated purex waste solutions  

International Nuclear Information System (INIS)

The rates of hydrogen release from simulated high-level liquid waste (SHLLW) during irradiation of "6"0Co #gamma#-rays have been studied using a laboratory-scale apparatus. The SHLLW used was made up of 28 different metal elements, the concentrations of which were determined from a computed data (ORIGEN-2) for a Purex spent fuel (burn-up of 4.5 GWd/t, cooling time of 4 years) except for those of corrosion products (Fe, Cr and Ni) and of chemical process additive (P). The nitrate ion concentration of the SHLLW was 4.97 M. The G-value of hydrogen release was 0.0164 for stirred conditions, but for nonstirred conditions with dose rate : 2.8 kGy/h and with the SHLLW solution height more than 8 cm, the following relation was found between the G-value and the solution height (d cm); G(H_2) = 0.100 d"-"1"."6. The G-values of oxygen and nitrogen releases were also determined. (author).

1997-01-01

436

Environmental cracking of the alpha-beta titanium alloy, Ti-6Al-6V-2Sn  

International Nuclear Information System (INIS)

The combined effects of environment, yield strength and stress state on the cracking susceptibility of beta-extruded Ti-6Al-6V-2Sn have been examined. At a constant yield strength and under plane strain conditions, the stress intensity required for slow crack propagation decreased as the severity of the environment increased, i.e., from laboratory air to 3.5% NaCl. Furthermore, the crack propagation rates were a function of both stress intensity, and environmental severity. Although the fracture toughness and threshold stress intensities for slow crack growth generally decreased with increasing yield strength, aging, which resulted in the precipitation of ordered Ti3Al particles in the primary alpha phase, tended to accentuate the susceptibility of this alloy to sustained load/stress corrosion cracking. Finally, at constant yield strength, the sustained load cracking threshold stress intensity was a function of stress state.

437

Activation of Polymethyl-Methacrylate by Proton Beam  

International Nuclear Information System (INIS)

Activation has been used for many kinds of useful applications, such as use of the radioisotopes for diagnosis and treatment of cancer, and wear (or corrosion) investigation for using thin layer activation (TLA) technique, etc. But activation also has severe problems for the post-processing of the samples; such as time-loss, inconvenience of sample handling, personal radiation safety, etc. For in-vitro experiments, we observed death of tumor cells by proton irradiation. The use of large activated container material can cause erroneous results in this case. To solve these problems, we studied why the samples were activated and how the level of the activation could be reduced. In proton beam irradiation experiments, the target materials could be defined as the container and sample itself. We could easily reduce activation of container material comparing to activation of sample itself. Therefore, we tried to find less activated container material by irradiating proton ...

2010-10-01

438

The role of grain boundary chemistry and structure in the environmentally-assisted intergranular cracking of nickel-base alloys. Progress report, August 1, 1991--July 31, 1992  

Energy Technology Data Exchange (ETDEWEB)

Stress corrosion cracking tests in constant extension rate tensile (CERT) and constant load tensile (CLT) tests were conducted on Ni-xCr- 9Fe-yC in Ar, water, and a LiOH-boric acid solution. Cr and C improve the resistance of Ni-base alloys to IG cracking in both Ar and water at 360C. Since creep plays a role in IG cracking, one possible explanation for the role of the environment involves its effect on the creep. Experiments were conducted on the role of C in the deformation behavior and failure mode of Ni-16Cr-9Fe. Constant load experiments were conducted on Ni-16Cr-9Fe to determine if the CLT test is more aggressive than CERT. The electron backscattering technique in a SEM is being developed in order to extend the IG cracking studies to grain sizes typical of commercial alloys, 20-30 microns.

1992-07-01

439

The role of grain boundary chemistry and structure in the environmentally-assisted intergranular cracking of nickel-base alloys  

Energy Technology Data Exchange (ETDEWEB)

Stress corrosion cracking tests in constant extension rate tensile (CERT) and constant load tensile (CLT) tests were conducted on Ni-xCr- 9Fe-yC in Ar, water, and a LiOH-boric acid solution. Cr and C improve the resistance of Ni-base alloys to IG cracking in both Ar and water at 360C. Since creep plays a role in IG cracking, one possible explanation for the role of the environment involves its effect on the creep. Experiments were conducted on the role of C in the deformation behavior and failure mode of Ni-16Cr-9Fe. Constant load experiments were conducted on Ni-16Cr-9Fe to determine if the CLT test is more aggressive than CERT. The electron backscattering technique in a SEM is being developed in order to extend the IG cracking studies to grain sizes typical of commercial alloys, 20-30 microns.

1992-07-01

440

Reliability engineering in aerospace technology. Approach to the assurance of high reliability; Eisei uchu rocket no shinraisei. Koshinraisei eno torikumi  

Energy Technology Data Exchange (ETDEWEB)

This paper describes an approach to the reliability engineering in aerospace technology. To promote development, configuration management (clarifies the base line of technology), reliability management, quality control, safety management, progress management, and cost management are very important. The following example related to reliability was contained for the development of an N-1 rocket in Japan. A timer and amplifier that are old-fashioned but have actual results were supplied from abroad. The induction system that was purchased from abroad contained faulty components in quality control. The improvement in reliability has priority and the first-stage tank was changed to a home-made aluminum alloy that is superior in stress-resistant corrosiveness. An H-II rocket was completely developed in Japan by self-technology. The number of faults to be generated in the H-II rocket decreases as compared with the N-1 rocket. In the combustion test of ...

1995-02-05

441

Improvement of leaching characteristics of TOC from condensate demineralizers  

International Nuclear Information System (INIS)

Recent nuclear power plants require high purity water to protect nuclear reactors or steam generators from SCC and maintain in good condition. In this connection, it is especially important to minimize sulfate, which is a corrosive chemical originated from oxidative degradation of cation exchange resins during operation. Recently, uniform particle size (UPS) strong acid cation gel resin with 14% cross-linkage, which has excellent stability against oxidization, has been applied to several condensate purification systems. For further improvement of water quality, some methods for changing the configuration of condensate demineralizer's resin bed have been examined. For example, these methods correspond to anion under layer and cation over layer. We have tested these methods by cold column tests. Furthermore, we have developed the newly anion exchange resin having higher efficiency and capacity for absorbing leachables from ...

2009-10-01

442

Effect of oxygen and oxidizing ions on denting corrosion  

International Nuclear Information System (INIS)

Information is presented concerning solute concentration in a porous layer; solute concentration in a packed crevice; corrosion of a packed carbon steel crevice in NaCl-O"2 solutions; and effect of copper on corrosion in NaCl-O"2 solutions.

1983-01-01

443

Corrosion and histopathological studies on anode materials for implantable power sources. [In vivo corrosion studies on anode material  

Science.gov (United States)

The biocompatibility and corrosion resistance of various materials for use as sacrificial anodes in in vivo hybrid fuel cells were studied. Aluminium, zinc, and magnesium alloy AZ31B were studied, and the results are discussed.

1974-01-01

444

Atmospheric corrosion in Gran Canaria specifically meteorological and pollution conditions.  

Science.gov (United States)

Carbon steel, copper, zinc and aluminium samples were exposed in different sizes with known ambient parameters in Gran Canaria Island and atmospheric corrosion was investigated. Weight-loss measurements used to determine corrosion damage were complemented...

1998-01-01

445

Precipitation behaviour of high-alloyed austenitic steels with 6% molybdenum and its influence on the corrosion resistance. Das Ausscheidungsverhalten von hochlegierten austenitischen Staehlen mit 6% Molybdaen und sein Einfluss auf die Korrosionsbestaendigkeit  

Energy Technology Data Exchange (ETDEWEB)

Time-temperature-precipitation diagrams have been established for two steels with 6% Mo, 21% Cr, 25% Ni, 0.14 and 0.19% N (Cronifer 1925 h Mo = 1.4529, UNS N 08925) and for one steel with 6% Mo, 20% Cr, 18% Ni and 0.21% N (UNS S 31 254). The corresponding time-temperature-sensitization diagrams (in accordance to SEP 1877/II) and time-temperature-pitting diagrams (testing in 6% FeCl{sub 3} solution) have been evaluated as well. Precipitation of intermetallics occurs rapidly especially in the range between 700 and 1000{sup 0}C. In case of the 18% Ni steel and the 25% Ni/0.14% N steel grain boundaries are covered to a large extent with precipitates after only 15 min at 850 or 950{sup 0}C. In case of the 25% Ni/0.19% N steel precipitation is considerably slower. Therefore, when welding according to established rules and recommendations, no deterioration of the corrosion resistance in the heat-affected zone is to be expected. Additionally, the steel ...

1989-08-01

446

Pitting and intergranular corrosion resistances of nitrogen ion implanted type 304 stainless steel  

International Nuclear Information System (INIS)

Type 304 stainless steel (SS) specimens sensitised at 873 K and 973 K for 1, 10 and 100 hours respectively were ion implanted using a 150 keV accelerator at an energy of 70 keV in two different doses of nitrogen namely 1 x 10"1"6 to 1 x 10"1"7 ions/cm"2. Ion implantation at 1 x 10"1"6 ions/cm"2 did not show any improvement in pitting resistance, however, the specimens implanted at 1 x 10"1"7 ions/cm"2 showed significant increase in pitting corrosion resistance when potentiodynamic anodic polarisation studies were carried out in acidic chloride medium. For specimens aged at 873 K, nitrogen ion implantation at 1 x 10"1"6 ions/cm"2 increased the intergranular corrosion susceptibility compared to that of unimplanted specimens. However, at the dose of 1 x 10"1"7 ions/cm"2, insignificant IGC attack was noticed. The IGC resistance increased with increase in the dose for all the specimens aged at 973 K, and the reduction in the electrochemical ...

1998-05-24

447

PFB coal fired combined cycle development program. Annual report, July 1978-June 1979  

Energy Technology Data Exchange (ETDEWEB)

The Coal Fired Combined Cycle (CFCC) is the unique powerplant concept developed under the leadership of the General Electric Company to provide a direct coal-burning gas turbine and steam turbine combined cycle powerplant. On the basis of previous studies and confirming work under this contract, General Electric continues to believe that the CFCC approach offers important advantages over alternate approaches: higher powerplant efficiency in the combustor temperature range of interest; reduced combustor/steam generator corrosion potential, due to low fluid-bed tube temperature (as contrasted to the air in tube cycle); and increased gas turbine bucket life from improved material protection systems. The objective of this program is to evaluate the coal fired combined cycle powerplant conceptual design, and to conduct a supporting development program. The supporting development is required for evaluating the pressurized fluidized bed combustion concept, for developing ...

1980-05-01

448

Modeling pitting corrosion damage of high-level radioactive-waste containers, with emphasis on the stochastic approach  

Energy Technology Data Exchange (ETDEWEB)

Recent efforts to identify methods of modeling pitting corrosion damage of high-level radioactive-waste containers are described. The need to develop models that can provide information useful to higher level system performance assessment models is emphasized, and examples of how this could be accomplished are described. Work to date has focused upon physically-based phenomenological stochastic models of pit initiation and growth. These models may provide a way to distill information from mechanistic theories in a way that provides the necessary information to the less detailed performance assessment models. Monte Carlo implementations of the stochastic theory have resulted in simulations that are, at least qualitatively, consistent with a wide variety of experimental data. The effects of environment on pitting corrosion have been included in the model using a set of simple phenomenological equations relating the parameters of the stochastic ...

1993-01-01

449

Advanced distillation curve measurement: Application to a bio-derived crude oil prepared from swine manure  

Energy Technology Data Exchange (ETDEWEB)

We have recently introduced several important improvements in the measurement of distillation curves for complex fluids. This new method is a significant improvement over current approaches, with features including a composition-explicit data channel for each distillate fraction (for both qualitative and quantitative analysis), trace chemical analysis of each distillate fraction, and a corrosivity assessment of each distillate fraction. In the present contribution, we present the application of the advanced distillation curve method to a bio-derived crude oil prepared from swine manure. One motivation behind the work was to precisely measure the distillation curve of the oil derived from swine manure with our advanced distillation apparatus and compare the bio-derived oil to traditional petroleum crude oils. Then, the information content of the bio-derived oil distillation was extended further with the composition-explicit data channel: gas chromatography-mass ...

2008-11-15

450

Research and development activities on high efficiency separation process technologies for carbon dioxide removal from industrial sources at University of Regina, Canada  

Energy Technology Data Exchange (ETDEWEB)

This paper describes research and development activities at the University of Regina, Saskatchewan, Canada on Optimization of CO{sub 2} Extraction Process Technologies. The ultimate goal of this research is to develop better and more effective CO{sub 2} separation processes which can be used to recover CO{sub 2} from industrial sources such as coal-fired power plants and coal gasification complexes at the lowest possible capital and operating costs. The research program has been supported by Saskatchewan Power Corporation, Saskatchewan Energy and Mines, Prairie Coal Ltd., the Canada Centre for Mineral and Energy Technology (CANMET), Fluor Daniel Inc. (USA), Sulzer Chemtech (Switzerland), Wascana Energy Inc., and Natural Sciences and Engineering Research Council of Canada (NSERC). Currently, six parallel and complementary projects have been carried out at the Process Systems Laboratory. These projects are: (1) Searching for new sterically hindered amines for high ...

1996-05-01

451

Release and sorption of alkali metals in coal fired combined cycle power systems; Freisetzung und Einbindung von Alkalimetallverbindungen in kohlebefeuerten Kombikraftwerken  

Energy Technology Data Exchange (ETDEWEB)

Coal fired combined cycle power systems will be a sufficient way to increase the efficiency of coal combustion. However, combined cycle power systems require a reliable hot gas cleanup. Especially alkali metals, such as sodium and potassium, can lead to hot corrosion of the gas turbine blading if they condensate as sulphates. The actual work deals with the release and sorption of alkali metals in coal fired combined cycle power systems. The influence of coal composition, temperature and pressure on the release of alkali species in coal combustion was investigated and the relevant release mechanisms identified. Alumosilicate sorbents have been found that reduce the alkali concentration in the hot flue gas of the Circulating Pressurized Fluidized Bed Combustion 2{sup nd} Generation (CPFBC 2{sup nd} Gen.) at 750 C to values sufficient for use in a gas turbine. Accordingly, alumosilicate sorbents working at 1400 C have been found for the Pressurized Pulverized Coal ...

2009-07-01

452

Corrosion resistance of Al sub 2 O sub 3 -C brick for in-bath smelting reduciton furnace. ; Laboratory study on application to post combustion zone. Tetsuyokushiki yoyu kangenroyo Al sub 2 O sub 3 -C renga no taishokusei. ; Niji nenshobu eno tekiyo ni kansuru jikkenshitsuteki kento  

Energy Technology Data Exchange (ETDEWEB)

The influence of (%MgO) and (%T.Fe) in slug on the corrosion resistance of Al{sub 2}O{sub 3}-C brick was studied at 1,550-1,800{degree}C to apply it to the post combustion zone of an in-bath smelting reduction furnace. The wear rate of the brick was affected strongly by temperature decreasing to 1 2-2 3 for every temperature reduction of 100{degree}C, and it was also more affected by (%T.Fe) than (%MgO) in slug at every temperature. The observation of brick microstructures by reflecting microscopy revealed the preceding wear of a carbon matrix. Based on the consideration that the growth of degraded structures by decarburization also contributes to movement of Al{sub 2}O{sub 3} clinkers, the wear rate equation of the Al{sub 2}O{sub 3}-C brick was derived taking into account not only elution of Al{sub 2}O{sub 3} clinkers into slug but oxidation and decarburization of the carbon matrix in oxidation atmosphere at high temperature, resulting in the good agreement ...

1991-06-10

453

Irradiation-assisted stress corrosion cracking of austenitic stainless steels: Recent progress and new approaches  

Energy Technology Data Exchange (ETDEWEB)

Irradiation-assisted stress corrosion cracking (IASCC) of several types of BWR field components fabricated from solution-annealed austenitic stainless steels (SSs), including a core internal weld, were investigated by means of slow-strain-rate test (SSRT), scanning electron microscopy (SEM), Auger electron spectroscopy (AES), and field-emission-gun advanced analytical electron microscopy (FEG-AAEM). Based on the results of the tests and analyses, separate effects of neutron fluence, tensile properties, alloying elements and major impurities identified in the American Society for Testing and Materials (ASTM) specifications, minor impurities, water chemistry, and fabrication-related variables were determined. The results indicate strongly that minor impurities not specified by the ASTM-specifications play important roles, probably through a complex synergism with grain-boundary Cr depletion. These ...

1996-09-01

454

Pitting corrosion of copper and copper alloys. (Latest citations from the EI Compendex*plus database). Published Search  

Energy Technology Data Exchange (ETDEWEB)

The bibliography contains citations concerning the pitting corrosion of copper and copper alloys by different media, with some references to methods that protect against such corrosion. Included are factors contributing to the onset of pitting corrosion. Emphasis is placed on exposure to water, especially in heat exchanger tubing and water conduits. Studies are included which examine corrosion in metals containing small amonts of copper where corrosion is attributable to changes in alloying. (Contains a minimum of 158 citations and includes a subject term index and title list.)

1994-04-01

455

Neural network for prediction of superheater fireside corrosion  

Energy Technology Data Exchange (ETDEWEB)

Superheater corrosion causes vast annual losses to the power companies. If the corrosion could be reliably predicted, new power plants could be designed accordingly, and knowledge of fuel selection and determination of process conditions could be utilized to minimize superheater corrosion. If relations between inputs and the output are poorly known, conventional models depending on corrosion theories will fail. A prediction model based on a neural network is capable of learning from errors and improving its performance as the amount of data increases. The neural network developed during this study predicts superheater corrosion with 80 % accuracy at early stage of the project. (orig.) 10 refs.

1998-12-31

456

Corrosion of hardened cement paste by acetic and nitric acids; Part 1: Calculation of corrosion depth  

Energy Technology Data Exchange (ETDEWEB)

The rate of corrosion of hardened cement paste in solutions of nitric, hydrochloric, sulfuric, acetic and formic acids was compared. Corrosion in solutions of acetic and nitric acids with different concentrations was studied in more detail. The results made it possible to obtain the relationships expressing the influence of concentration and the time of action of acid solutions on the depth of corrosion. The rates of corrosion in nitric acid solutions during the first 3 years were about 2 to 4 times that in acetic acid solutions, depending on the concentration.

1994-01-01

457

Corrosion and reliability of PWR power plants  

International Nuclear Information System (INIS)

Corrosion is increasingly becoming an important factor reducing the reliability of many nuclear power plant components. The significance is evaluated of corrosion phenomena with respect to the reliability of primary circuit components of LWR's, viz., the reactor pressure vessel, primary piping, steam generator, and fuel elements. The mechanism of corrosion phenomena is explained and methods of minimizing their effects are presented. An analysis is made of the needs to solve the corrosion problems of nuclear power plants from the point of view of Czechoslovak producers and research and development activities. International cooperation is reviewed and main problems are formulated on which the solution of corrosion problems of structural materials used in WWER type nuclear power plants should be focussed. (author).

458

Atmospheric corrosion in Gran Canaria specifically meteorological and pollution conditions  

Energy Technology Data Exchange (ETDEWEB)

Carbon steel, copper, zinc and aluminium samples were exposed in different sizes with known ambient parameters in Gran Canaria Island and atmospheric corrosion was investigated. Weight-loss measurements used to determine corrosion damage were complemented with metallographic and XP S determination in order to characterize the structure and morphology of surface corrosion products. The ambient aggressiveness could be well evaluated from meteorological and pollution data. All atmospheric corrosion and environmental data were statistically processed for establishing general corrosion damage functions for carbon steel, copper, aluminium and zinc in terms of Gran Canaria extreme meteorological and pollution parameters. (Author)

1998-12-31

459

The Los Alamos National Laboratory Environmental Restoration Program  

Energy Technology Data Exchange (ETDEWEB)

The LANL Environmental Restoration (ER) Program Office, established in October 1989, is faced with the challenge of assessing and cleaning up nearly 1,8000 potentially hazardous waste sites according to an aggressive corrective action schedule that the Environmental Protection Agency (EPA) mandated on May 23, 1990, in a Resource, Conservation, and Recovery Act (RCRA) Part B Permit. To maximize program efficiency, the ER Program Office will implement a unique management approach designed to maximize the use of laboratory technical expertise. The Installation Work Plan, which provides a blueprint for the program, has been submitted to EPA for review and approval. A work plan for characterization of Technical Area 21, an early plutonium processing facility, is also nearing completion. The feasibility of an expedited cleanup of the Laboratory's worst hazardous waste release has been modelled using a computer code originally developed by ...

1990-01-01

460

Facility Effluent Monitoring Plan for Pacific Northwest National Laboratory Balance-of-Plant Facilities  

Energy Technology Data Exchange (ETDEWEB)

The Pacific Northwest National Laboratory (PNNL) operates a number of research and development (R and D) facilities for the Department of Energy on the Hanford Site. According to DOE Order 5400.1, a Facility Effluent Monitoring Plan is required for each site, facility, or process that uses, generates, releases, or manages significant pollutants or hazardous materials. Three of the R and D facilities: the 325, 331, and 3720 Buildings, are considered major emission points for radionuclide air sampling and thus individual Facility Effluent Monitoring Plans (FEMPs) have been developed for them. Because no definition of ''significant'' is provided in DOE Order 5400.1 or the accompanying regulatory guide DOE/EH-0173T, this FEMP was developed to describe monitoring requirements in the DOE-owned, PNNL-operated facilities that do not have individual FEMPs. The remainder of the DOE-owned, PNNL-operated facilities are referred to as ...

1999-04-02

461

CANMET's environmental and process research on uranium  

International Nuclear Information System (INIS)

Environmental research related to uranium tailings is being carried out within the Mining Research Laboratories and Mineral Sciences Laboratories of CANMET, EMR. Field-related research on uranium tailings has been conducted at Elliot Lake for over five years. Much of the work has been focused on a program to rehabilitate pyritic tailings. This has resulted in developing a practicable technology for growing vegetation on such wastes. Limitations have been small size of the test-plots and the relatively short period during which experiments have been carried out. A research program aimed at identifying and reducing acidic and radioactive effluents is also underway at Elliot Lake. These liquid effluents have been identified as the most serious threat to the environment. Research at the Mineral Sciences Laboratories and its predecessor divisions relating to the processing of uranium and thorium ores is ...

462

A summary of neutron radiography and neutron radioscopy applications at the University of Michigan Phoenix Memorial Laboratory  

International Nuclear Information System (INIS)

Neutron radiography and neutron radioscopy are rapidly becoming the valuable tools for nondestructive testing and basic research. The Phoenix Memorial Laboratory has developed a neutron facility capable of both film neutron radiography and real time neutron radioscopy, and has used this facility to study several phenomena of interest to the researchers in many areas. Neutrons can be used for imaging the phenomena that X-ray cannot image, such as the presence, absence or movement of hydrogenous materials inside metals such as aluminum or steel. There are three basic methods for obtaining images using neutrons: high resolution film neutron radiography, real-time neutron radioscopy and transfer film neutron radiography. The neutron radiography facility at Phoenix Memorial Laboratory, the neutron radioscopic imaging systems, the neutron radiographic detectors, lubrication studies, spray imaging, flow in porous media, ...

1992-03-01

463

Steam generator tube performance: experience with water-cooled nuclear power reactors during 1979  

International Nuclear Information System (INIS)

The performance of steam generator tubes in water-cooled nuclear power reactors has been reviewed for 1979. Tube failures occurred at 38 of the 93 reactors surveyed. Causes of these failures and procedures designed to deal with them are described. The defect rate was twice that in 1978 but still lower than the two previous years. Methods being employed to detect defects include increasing use of multifrequency eddy-current testing and a trend to full-length inspection of all tubes. To reduce the incidence of tube failures by corrosion, plant operators are turning to full-flow condensate demineralization and more leak-resistant condenser tubes. (author).

1994-10-18

464

Heat transfer characteristics of superheater in the kraft recovery boiler; Soda kaishu boiler no kanetsuki ni okeru netsuryudo tokusei  

Energy Technology Data Exchange (ETDEWEB)

Accurate prediction of tube surface temperature is important for determining whether accelerated superheater corrosion will occur in kraft recovery boilers. A heat transfer model, which combines an iterative numerical solution scheme with a more realistic flue gas flow field obtained from the CFD code FLUENT, has been developed to predict the tube, steam and flue gas temperatures in the superheater region. Results of tests performed for a recovery boiler show that temperatures predicted using the model are in good agreement with actual temperatures measured using thermocouples. The presence of a large flue gas recirculation zone above the bullnose is shown to have an adverse effect on the heat transfer in the superheater region. 9 refs., 12 figs., 1 tab.

1997-03-25

465

GRI's Gas Appliance Technology Center Activities at Battelle. Final report, 1986-1992  

Science.gov (United States)

The Gas Research Institute established the Gas Appliance Technology Center (GATC) in 1982 to develop improved gas appliances. Between 1986 and 1992, the scope of GATC activities at Battelle included technology transfer and overall industry support, residential appliances, commercial appliances, and residential space conditioning. The following tasks are representative of the GATC activities described in the report; gas burner technology, appliance venting, emissions, water heating, range/oven technology, self-powered appliances, commercial cooktop burners, reconstituting ovens, appliance reliability improvement, combination space-heating/water-heating systems, condensing heat exchangers, corrosion testing, and space heating technology. The report includes references to available sources for further reading.

1993-08-01

466

Corrosion damage assessment of WWER steam generator primary collectors  

Energy Technology Data Exchange (ETDEWEB)

Titanium stabilized austenitic steel is sensitive to SCC in the secondary water under the horizontal steam generator operating conditions. SCC was observed under crevice conditions both at the primary collector flanges and the heat exchange tubes. In the crevice environment sulfates and chlorides as aggressive species and silicates and alumino-silicates as ''non-aggressive'' species are present in significant amounts. Local water chemistry parameters were evaluated using the MULTEQ Code. SCC experiments were carried out by rising displacement tests ar 275 deg C in an environment simulating the crevice conditions. Crack growth rate and K{sub IS}8C{sub C} were determined for the environment where contents of some species were from 10{sup 2} to 10{sup 4} times higher than in blowdowns. (authors)

1998-07-01

467

Corrosion damage assessment of WWER steam generator primary collectors  

International Nuclear Information System (INIS)

Titanium stabilized austenitic steel is sensitive to SCC in the secondary water under the horizontal steam generator operating conditions. SCC was observed under crevice conditions both at the primary collector flanges and the heat exchange tubes. In the crevice environment sulfates and chlorides as aggressive species and silicates and alumino-silicates as ''non-aggressive'' species are present in significant amounts. Local water chemistry parameters were evaluated using the MULTEQ Code. SCC experiments were carried out by rising displacement tests ar 275 deg C in an environment simulating the crevice conditions. Crack growth rate and K_I_S8C_C were determined for the environment where contents of some species were from 10"2 to 10"4 times higher than in blowdowns. (authors)

1998-09-14

468

Application of electrochemically dissolved iron in the removal of tannic acid from water  

British Library Electronic Table of Contents (United Kingdom)

Effects of some experimental parameters (supporting electrolyte, initial pH and current density) on the performance of electrocoagulation process using iron electrodes were investigated. Results of experiments showed that dissolution of iron is purely electrochemical and fits well with Faraday's law and leads to Fe^2^+ which are chemically oxidized into Fe^3^+ in aerated conditions. In neutral and alkaline conditions, the reaction between hydroxyl ions generated at the cathode and dissolved iron ions forms insoluble hydroxo-iron species. Potentiodynamic polarization tests showed that the formation of passive film on iron anode limits the continuous electrochemical dissolution of iron. Corrosion and pitting potentials largely depend on the nature of supporting electrolyte. The dissolution o...

2011-01-01

469

Hydrogeology and tritium transport in Chicken Creek Canyon,Lawrence Berkeley National Laboratory, Berkeley, California  

Energy Technology Data Exchange (ETDEWEB)

This study of the hydrogeology of Chicken Creek Canyon wasconducted by the Environmental Restoration Program (ERP) at LawrenceBerkeley National Laboratory (LBNL). This canyon extends downhill fromBuilding 31 at LBNL to Centennial Road below. The leading edge of agroundwater tritium plume at LBNL is located at the top of the canyon.Tritium activities measured in this portion of the plume during thisstudy were approximately 3,000 picocuries/liter (pCi/L), which issignificantly less than the maximum contaminant level (MCL) for drinkingwaterof 20,000 pCi/L established by the Environmental ProtectionAgency.There are three main pathways for tritium migration beyond theLaboratory s boundary: air, surface water and groundwater flow. Thepurpose of this report is to evaluate the groundwater pathway.Hydrogeologic investigation commenced with review of historicalgeotechnical reports including 35 bore logs and 27 test pit/trench logsas ...

2007-10-31

470

Corrosion behavior of iron and nickel base alloys in high temperature and pressure water  

International Nuclear Information System (INIS)

In equipment industries, the equipments handling industrial water and pure water are numerous. In power generation including nuclear power generation, water serves as a working medium. Review is made on the experiences in the corrosion of iron and nickel base alloys in high temperature, high pressure water and the results of researches derived from them. Under high temperature and high pressure, carbon steel, low alloy steel, stainless steel and high nickel alloy cause corrosion even in pure water. But in the case of serious corrosion, chlorine, oxygen, alkali and others in water take part. The following matters are described: corrosion by steam; stress corrosion cracking in pure water; corrosion by impurities in high temperature, high pressure pure water, i.e. chlorine ions, dissolved oxygen, and alkali; corrosion under radiation. (J.P.N.).

471

A study on the degradation of coating and corrosion of ship`s hull based on the probabilistic approach  

Energy Technology Data Exchange (ETDEWEB)

Corrosion is said to be the most dominant factor which affects the physical life of ships and offshore structures. In order to secure the structural safety of ships and offshore structures, it is necessary to take measures to corrosion based on the prediction of condition of progressive corrosion. But such prediction is difficult because the behavior of corrosion`s progress is probabilistic. In this paper, probabilistic model, which could evaluate the degradation of coatings and the successive corrosion of steel members, was proposed in order to explain the tendency of the actual corrosion conditions of existing ships. Then, statistical inferences on the proposed model were made by applying the actual data on plate thickness measurements of Bulk Carriers` Cargo Hold. And validity of the proposed model was verified.

1996-12-31

472

Ultra-high tritium decontamination of simulated fusion fuel exhaust using a 2-stage palladium membrane reactor  

Energy Technology Data Exchange (ETDEWEB)

A 2-stage cold (non-tritium) PMR system was tested with the ITER mix in61 days of continuous operation. No decrease in performance was observed over the duration of the test. Decontamination factor (DF) was found to increase with decreasing inlet rate. Decontamination factors in excess of 1.4 {times} 10{sup 5} were obtained, but the exact value of the highest DF could not be determined because of analysis limitations. Results of the 61-day test were used to design a 2-stage PMR system for use in tritium testing. The PMR system was scaled up by a factor of 6 and built into a glovebox in the Tritium Systems Test Assembly (TSTA) of the Los Alamos National Laboratory. This system is approximately 1/5th of the expected full ITER scale. The ITER mix was injected into the PMR system for 31 hours, during which 4.5 g of tritium were processed. The 1st stage had DF = 200 ...

1996-12-31

473

Ultra-high tritium decontamination of simulated fusion fuel exhaust using a 2-stage palladium membrane reactor  

International Nuclear Information System (INIS)

A 2-stage cold (non-tritium) PMR system was tested with the ITER mix in 61 days of continuous operation. No decrease in performance was observed over the duration of the test. Decontamination factor (DF) was found to increase with decreasing inlet rate. Decontamination factors in excess of 1.4x10"5 were obtained, but the exact value of the highest DF could not be determined because of analysis limitations. Results of the 61-day test were used to design a 2-stage PMR system for use in tritium testing. The PMR system was scaled up by a factor of 6 and built into a glovebox in the Tritium Systems Test Assembly (TSTA) of the Los Alamos National Laboratory. This system is approximately 1/5"t"h of the expected full ITER scale. The ITER mix was injected into the PMR system for 31 hours, during which 4.5 g of tritium were processed. The 1"s"t stage had DF =200 and the ...

1996-06-16

474

Fatigue behavior of vertical axis wind turbine airfoils with two weld configurations  

Energy Technology Data Exchange (ETDEWEB)

Sandia National Laboratories contracted with Rockwell International Science Center to perform a series of narrowband, pseudo-random cyclic fatigue tests on sections of 6063-T651 aluminum, Darrius-type, vertical axis wind turbine (VAWT) airfoils. We designed and constructed a load member that was mounted within the frame of a rigid 200-kip servohydraulic, closed-loop test system to hold the VAWT section and permit cantilever bending along the shear centerline of the beam. A computer program was developed to synthesize a narrow band, pseudo-random load history with fixed root mean square (RMS) stress levels at a given bandwidth and central frequency. Six specimens each of two different weld configurations at the flange mounting plate were tested at several RMS stress levels with failure defined as visual observation of a 3-inch-long crack in the VAWT. In order to test at as great a ...

1989-10-01

475

Accelerated aging tests of liners for uranium mill tailings disposal  

Energy Technology Data Exchange (ETDEWEB)

This document describes the results of accelerated aging tests to determine the long-term effectiveness of selected impoundment liner materials in a uranium mill tailings environment. The study was sponsored by the US Department of Energy under the Uranium Mill Tailings Remedial Action Project. The study was designed to evaluate the need for, and the performance of, several candidate liners for isolating mill tailings leachate in conformance with proposed Environmental Protection Agency and Nuclear Regulatory Commission requirements. The liners were subjected to conditions known to accelerate the degradation mechanisms of the various liners. Also, a test environment was maintained that modeled the expected conditions at a mill tailings impoundment, including ground subsidence and the weight loading of tailings on the liners. A comparison of installation costs was also performed for the candidate liners. The laboratory ...

1981-11-01

476

Monthly report of activities: APRIL 1, 1969  

Science.gov (United States)

This is the first of a series of monthly reports summarizing the status of the work of the National Accelerator Laboratory. This first report will cover developments since the publication of the Design Report in January. Authorization hearings were held before the Joint Committee on Atomic Energy on February 21, 1968. Dr. Wilson described the plans and designs of the Laboratory. The present plan of the Laboratory is that the Village of Weston will be utilized for office, laboratory, and shop space during construction. The Laboratory business office is already occupying several houses. The linac section is occupying three houses for offices and construction of an 8,000 sq ft laboratory building for linac work is almost complete. Another house is being used and a 4,500 sq ft inflatable building is being constructed for model-magnet and vacuum ...

1968-04-01

477

Hydrologic Tests at Characterization Wells R-9i, R-13, R-19, R-22, and R-31  

Energy Technology Data Exchange (ETDEWEB)

Hydrologic information is essential for environmental efforts at Los Alamos National Laboratory. Testing at new characterization wells being drilled to the regional aquifer (''R wells'') to improve the conceptual hydrogeologic model of the Pajarito Plateau is providing such information. Drilling has been by air-rotary casing-advance or open-hole methods. Most wells are completed with multiple screens. After their construction, wells were rigorously developed by wire-brushing, bailing, followed by surging, swabbing, or jetting, and finally by pumping. These methods are effective based on field-parameter measurements and comparison of results of hydrologic testing at well R-31 before and after complete well development. We conducted field tests on various zones of saturation penetrated by the R wells to collect data needed for determining hydraulic properties. This ...

2003-03-01

478

Corrosion of 304 stainless steel in molten-carbonate fuel cells  

Energy Technology Data Exchange (ETDEWEB)

The corrosion behavior of 304 stainless steel was characterized with cyclic voltammetry in a eutectic Li/K and Li/Na carbonate melt under anode and cathode gas of the molten-carbonate fuel cell (MCFC). The corrosion rate of 304 steel was determined in four different environments of the MCFC with electrochemical methods and from cross-sectional analysis of corrosion layers. These four environments were open-circuit and MCFC-load conditions both under anode and cathode gas. At open-circuit conditions corrosion was more severe under the oxidizing cathode gas then under the reducing anode gas. On the contrary, at load conditions corrosion was more severe under anode than under cathode gas. The anodic polarization under anode gas enhances corrosion, whereas the high anodic polarization under cathode gas leads to anodic protection. Corrosion ...

1999-07-01

479

Interrelation between grain boundary characteristics and intergranular stress corrosion cracking of thermally treated alloy 690 and shot peened alloy 800 in high temperature acidic and alkaline solution  

Energy Technology Data Exchange (ETDEWEB)

To clarify the acidic and alkaline Intergranular Stress Corrosion Cracking (IGSCC) mechanism of thermally treated alloy 690 (alloy 690 TT) and shot peened alloy 800 (alloy 800 SP), C-ring tests were conducted in deaerated HCl solutions and in deaerated NaOH solutions at 350degC, compared with the acidic and the alkaline IGSCC susceptibilities of mill-annealed alloy 600 (alloy 600 MA), full-sensitized one (alloy 600 FS) and thermally treated one (alloy 600 TT). Grain boundary characteristics, such as chromium depleted zone and chromium carbide precipitation, were examined using modified Huey test and Transmission Electron Microscopy. Potential-pH diagram for Ni, Cr, Fe-H{sub 2}O system at 350degC was constructed and the solubilities of NiO, Cr{sub 2}O{sub 3} and Fe{sub 3}O{sub 4} were also calculated to evaluate the stability of oxide films which were formed on the surfaces of alloy 690, 800 and 600. Under the acidic ...

2001-05-01

480

Interrelation between grain boundary characteristics and intergranular stress corrosion cracking of thermally treated alloy 690 and shot peened alloy 800 in high temperature acidic and alkaline solution  

International Nuclear Information System (INIS)

To clarify the acidic and alkaline Intergranular Stress Corrosion Cracking (IGSCC) mechanism of thermally treated alloy 690 (alloy 690 TT) and shot peened alloy 800 (alloy 800 SP), C-ring tests were conducted in deaerated HCl solutions and in deaerated NaOH solutions at 350degC, compared with the acidic and the alkaline IGSCC susceptibilities of mill-annealed alloy 600 (alloy 600 MA), full-sensitized one (alloy 600 FS) and thermally treated one (alloy 600 TT). Grain boundary characteristics, such as chromium depleted zone and chromium carbide precipitation, were examined using modified Huey test and Transmission Electron Microscopy. Potential-pH diagram for Ni, Cr, Fe-H_2O system at 350degC was constructed and the solubilities of NiO, Cr_2O_3 and Fe_3O_4 were also calculated to evaluate the stability of oxide films which were formed on the surfaces of alloy 690, 800 and 600. Under the acidic condition, the IGSCC ...

2001-05-01

481

IMPROVED NATURAL GAS STORAGE WELL REMEDIATION  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the research conducted during Budget Period One on the project ''Improved Natural Gas Storage Well Remediation''. The project team consisted of Furness-Newburge, Inc., the technology developer; TechSavants, Inc., the technology validator; and Nicor Technologies, Inc., the technology user. The overall objectives for the project were: (1) To develop, fabricate and test prototype laboratory devices using sonication and underwater plasma to remove scale from natural gas storage well piping and perforations; (2) To modify the laboratory devices into units capable of being used downhole; (3) To test the capability of the downhole units to remove scale in an observation well at a natural gas storage field; (4) To modify (if necessary) and field harden the units and then test the units in two pressurized injection/withdrawal gas ...

2001-12-01

482

Water Retention Capacity of Argillite from the VE Test - Phase II at Mont Terri: Effect of Ventilation  

International Nuclear Information System (INIS)

The VE (ventilation) test carried out at the Mont Terri underground laboratory in Switzerland intended to evaluate in situ the behaviour of a consolidated clay formation when subjected to alternate periods of flow of wet and dry air during several months. For that, a 10-m gallery was excavated in the Opalinus Clay formation and carefully instrumented. Before and after a second ventilation phase boreholes were drilled. Samples were taken from the drill cores and were analysed from mineralogical and geochemical points of view. Also, the retention curves of these samples were determined in the laboratory following drying paths performed under free volume conditions at 20 degree centigrade, what is the content of this report. Although there are not large differences in the WRC of samples taken from different boreholes, at different distances from the gallery wall or before or after ventilation, those samples taken near the ...

2010-11-01

483

Report on Thermo-Hydro-Mechanical Laboratory Tests Performed by CIEMAT on Febex Bentonite 2004-2008  

International Nuclear Information System (INIS)

The results of the laboratory studies performed by CIEMAT with the FEBEX bentonite in the context of WP3.2 of the NF-PRO Project and of the Agreement ENRESA-CIEMAT Anexo V are presented and analysed in this report. They refer to the effect of the hydraulic gradient on the permeability of bentonite, the effect of the thermal gradient on the hydration kinetics of bentonite, and the repercussion of temperature on the hydro-mechanical properties of bentonite (swelling, permeability and water retention capacity). In all the cases the bentonite has been used compacted to densities expected in the engineered barrier of a high-level radioactive waste repository. The existence of threshold and critical hydraulic gradients has been observed, both of them dependent on bentonite density and water pressures. After more than seven years of hydration, the 40-cm high bentonite columns are far from full saturation, the thermal gradient additionally delaying the process, which is ...

484

Report on Thermo-Hydro-Mechanical Laboratory Tests Performed by CIEMAT on Febex Bentonite 2004-2008  

Energy Technology Data Exchange (ETDEWEB)

The results of the laboratory studies performed by CIEMAT with the FEBEX bentonite in the context of WP3.2 of the NF-PRO Project and of the Agreement ENRESA-CIEMAT Anexo V are presented and analysed in this report. They refer to the effect of the hydraulic gradient on the permeability of bentonite, the effect of the thermal gradient on the hydration kinetics of bentonite, and the repercussion of temperature on the hydro-mechanical properties of bentonite (swelling, permeability and water retention capacity). In all the cases the bentonite has been used compacted to densities expected in the engineered barrier of a high-level radioactive waste repository. The existence of threshold and critical hydraulic gradients has been observed, both of them dependent on bentonite density and water pressures. After more than seven years of hydration, the 40-cm high bentonite columns are far from full saturation, the thermal gradient additionally delaying the process, which is ...

2009-11-25

485

Low-Cost, Robust, Threat-Aware Wireless Sensor Network for Assuring the Nation's Energy Infrastructure  

Energy Technology Data Exchange (ETDEWEB)

Eaton, in partnership with Oak Ridge National Laboratory and the Electric Power Research Institute (EPRI) has completed a project that applies a combination of wireless sensor network (WSN) technology, anticipatory theory, and a near-term value proposition based on diagnostics and process uptime to ensure the security and reliability of critical electrical power infrastructure. Representatives of several Eaton business units have been engaged to ensure a viable commercialization plan. Tennessee Valley Authority (TVA), American Electric Power (AEP), PEPCO, and Commonwealth Edison were recruited as partners to confirm and refine the requirements definition from the perspective of the utilities that actually operate the facilities to be protected. Those utilities have cooperated with on-site field tests as the project proceeds. Accomplishments of this project included: (1) the design, modeling, and simulation of the anticipatory wireless sensor ...

2007-03-31

486

Integration of advanced nuclear materials separation processes  

Energy Technology Data Exchange (ETDEWEB)

This is the final report of a two-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). This project has examined the fundamental chemistry of plutonium that affects the integration of hydrothermal technology into nuclear materials processing operations. Chemical reactions in high temperature water allow new avenues for waste treatment and radionuclide separation.Successful implementation of hydrothermal technology offers the potential to effective treat many types of radioactive waste, reduce the storage hazards and disposal costs, and minimize the generation of secondary waste streams. The focus has been on the chemistry of plutonium(VI) in solution with carbonate since these are expected to be important species in the effluent from hydrothermal oxidation of Pu-containing organic wastes. The authors investigated the structure, solubility, and stability of the key plutonium complexes. ...

1998-12-31

487

Ensuring the 50 year life of a fissile material container  

Energy Technology Data Exchange (ETDEWEB)

Sandia was presented with an opportunity in 1993 to design containers for the long term storage and transport of fissile material. This program was undertaken at the direction of the US Department of Energy and in cooperation with Lawrence Livermore National Laboratory and Los Alamos National Laboratory which were tasked with developing the internal fixturing for the contents. The hardware is being supplied by Allied Signal Federal Manufacturing and Technologies, and the packaging will occur at Mason and Hangar Corporation`s Pantex Plant. The unique challenge was to design a container that could be sealed with the fissile material contents; and, anytime during the next 50 years, the container could be transported with only the need for the pre-shipment leak test. This required not only a rigorous design capable of meeting the long term storage and transportation requirements, but also resulted in development of a ...

1997-12-01

488

Biological treatment process for removing petroleum hydrocarbons from oil field produced waters  

Energy Technology Data Exchange (ETDEWEB)

The feasibility of removing petroleum hydrocarbons from oil fields produced waters using biological treatment was evaluated under laboratory and field conditions. Based on previous laboratory studies, a field-scale prototype system was designed and operated over a period of four months. Two different sources of produced waters were tested in this field study under various continuous flow rates ranging from 375 1/D to 1,800 1/D. One source of produced water was an open storage pit; the other, a closed storage tank. The TDS concentrations of these sources exceeded 50,000 mg/l; total n-alkanes exceeded 100 mg/l; total petroleum hydrocarbons exceeded 125 mg/l; and total BTEX exceeded 3 mg/l. Removals of total n-alkanes, total petroleum hydrocarbons, and BTEX remained consistently high over 99%. During these tests, the energy costs averaged $0.20/bbl at 12 bbl/D.

1995-12-31

489

Studies on the CRUD Deposition on Fuel Cladding Surface Using AOA Water Chemistry Loop  

International Nuclear Information System (INIS)

Axial offset anomaly (AOA) is caused by the deposition of crud on the fuel cladding of a PWR. When significant levels of crud build up on the cladding, boron can accumulate in the pores of the crud as a concentrated solution or solid phase, and cause the flux depression. Numerous studies have been conducted on the primary water chemistry to reduce the amount of crud in the primary circuit to avoid radioactivity buildup and unexpected power transition in the plant. However, experiments on the crud are restricted in the laboratory because the crud is a highly radioactive material. The objective of this study is to develop a test method for simulating the deposition of crud in a nuclear power plant

2010-10-01

490

Gamma Radiation Detectors of the TA-55 Waste Line Monitoring System  

Energy Technology Data Exchange (ETDEWEB)

This report covers the gamma detectors, measurement instrumentation, and testing results of a system developed at Los Alamos National Laboratory. This system monitors the process liquid waste streams at the Plutonium Facility (TA-55) for the presence of radioactive contamination. The detectors are at various points on the acid, caustic, and industrial waste lines. Two of the detectors are on the sanitary sewer lines from the facility. A custom interface unit associated with these two detectors furnishes the facility operation center with a notification of the detection of material. All of the detectors furnish measurement information to a central computer system for storage and trending.

1999-06-01

491

Finite element prediction of differential eddy current probe signals from Fe _30_4 deposits in PWR steam generators  

International Nuclear Information System (INIS)

The paper is concerned with the simulation of practical testing situations which are too difficult and/or expensive to replicate in a laboratory environment. Numerical experiments are described which simulate the differential eddy current probe response to the build-up and chemical flushing of magnetite in the crevice gap of a PWR steam generator unit. The simulation results agree well with the only experimental data available to the authors and lead to the conclusion that conventional differential eddy current probes should be capable of characterizing crevice gap conditions with respect to the presence of magnetite. (author).

1985-01-01

492

Electric and Hybrid Vehicles Program. Sixteenth annual report to Congress for fiscal year 1992  

Energy Technology Data Exchange (ETDEWEB)

This report describes the progress achieved in developing electric and hybrid vehicle technologies, beginning with highlights of recent accomplishments in FY 1992. Detailed descriptions are provided of program activities during FY 1992 in the areas of battery, fuel cell, and propulsion system development, and testing and evaluation of new technology in fleet site operations and in laboratories. This Annual Report also contains a status report on incentives and use of foreign components, as well as a list of publications resulting from the DOE program.

1993-08-01

493

Comprehensive view of BMFT-funded research on forest decline. Gesamtdarstellung der oeffentlich gefoerderten Forschung ueber Waldschaeden  

Energy Technology Data Exchange (ETDEWEB)

Since 1983, about 600 research projects received a total of DM 250 million public funds for the following tasks: - Development of scientific fundamentals for monitoring and observation of forest decline and its ecological and economic consequences. - Investigation of the cause-effect relationship of forest damage, with particular regard to the involvement of the various compartments of the forest ecosystem and to the contribution of different pollutants. - Development of the scientific fundamentals required for forestry measures to accompany the air pollution abatement measures. The investigations comprised both laboratory and field tests. The findings and conclusion are summarized. (orig./MG).

1988-12-01

494

Change in high-temperature strength properties of 12Kh1MF steel in long-term loading under creep conditions  

Energy Technology Data Exchange (ETDEWEB)

Stress-rupture strength tests were made of metal steam pipe (12Kh1MF steel) in various conditions, the original, after aging under laboratory conditions (580{degrees}C, 10,000 h), and after long service. It was shown that the more the steel is hardened by heat treatment or cold plastic working in the original condition, the less it hardens in creep. It was established that softening in creep of steel with a moderate yield strength is caused primarily by aging and with a high yield strength by pore formation.

1995-01-01

495

An experimental investigation of the Hahn-Noll revenue neutral auction for emissions licenses  

Energy Technology Data Exchange (ETDEWEB)

This paper reports on three series of laboratory experiments designed to test the performance of the Hahn-Noll revenue neutral auction (RNA). An alternative institution, a no-rebate uniform price auction (UPA), is also examined as a benchmark. In these experiments, the RNA markets were little different from UPA markets in terms of either prices or market efficiencies. The two institutions did differ in terms of the distribution of the gains from exchange and of the propensity of bidders to engage in a certain type of overbidding. 25 refs., 13 figs., 3 tabs.

1993-01-01

496

Advanced concepts report on the detection of xenon with a miniature whole air sampler capable of extended operating times  

Energy Technology Data Exchange (ETDEWEB)

Many monitoring activities require the collection of whole air samples over an extended time interval without loss or concentration of any atmospheric constituents. Described is the development and laboratory testing of a whole air sampler capable of collecting a 100 liter sample over a period of 0.63 days. The sampler has an empty weight of 7.79 kg and an overall size of 20.8-cm {times} 20.8-cm {times} 66.1-cm. The conceptual design for the development of smaller, higher-performance whole air samplers is also reported.

1993-07-01

497

A study of aging effects in gas proportional detectors at the BAC calorimeter of the ZEUS experiment  

Energy Technology Data Exchange (ETDEWEB)

The multicell proportional chambers at the backing calorimeter of the ZEUS experiment at the storage ring HERA are supplied with a gas mixture of Ar/CO[sub 2] by an open gas system. Flow proportional counters with the build-up [sup 55]Fe sources are used as gas system monitoring detectors. The ZEUS experiment is planned to collect data for about 10 years. Therefore, the lifetime of the Ar/CO[sub 2] mixture should be known. In this paper, the results of laboratory tests and preliminary measurements of the aging effects for monitoring counters are presented. ((orig.))

1994-09-01