WorldWideScience
 
 
1

Sodium ion-dependent amino acid transport in membrane vesicles of Bacillus stearothermophilus.  

UK PubMed Central (United Kingdom)

Amino acid transport in membrane vesicles of Bacillus stearothermophilus was studied. A relatively high concentration of sodium ions is needed for uptake of L-alanine (Kt = 1.0 mM) and L-leucine (Kt...Full Text Available

1991-01-01

2

Development and evaluation for passive dosimeter using several solid dosimeters  

International Nuclear Information System (INIS)

Passive dosimeters for personal and area radiation monitor in space have been developed mainly for dosimetry in low-earth-orbit (LEO) radiation environments of Space Shuttles and the International Space Station. The responses of several dosimeters have been evaluated by heavy ions and also its variation for individual dosimeter element. (author)

2005-05-01

3

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

International Nuclear Information System (INIS)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. ...

2008-05-01

4

Mini-conference on Angular Momentum Transport in Laboratory and Nature  

Energy Technology Data Exchange (ETDEWEB)

This paper provides a concise summary of the current status of the research and future perspectives discussed in the Mini-Conference on Angular Momentum Transport in Laboratory and Nature. This Mini-conference, sponsored by the Topical Group on Plasma Astrophysics, was held as part of the American Physical Society's Division of Plasma Physics 2007 Annual Meeting (November 12{16, 2007). This Mini-conference covers a wide range of phenomena happening in fluids and plasmas, either in laboratory or in nature. The purpose of this paper is not to comprehensively review these phenomena, but to provide a starting point for interested readers to refer to related research in areas other than their own.

2008-05-06

5

Methodology for fabrication of hydraulics mini turbines with composite materials; Metodologia para a fabricacao de mini turbinas hidraulicas com materiais compostos  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the description of methodological procedure specially developed for manufacturing mini turbines. This procedure is used in the design of a Francis type mini turbine with 12.5 kW. The housing volute and the suction tube of this equipment are manufactured with using composed material based on glass fiber and its distributor system is manufactured with stainless steel and brass. At the end it is presented an estimate cost of design / manufacturing of such equipment and a comparison with other equipment in the market.

2009-07-01

6

Development of mini-LIA and primary experiments  

International Nuclear Information System (INIS)

Mini-LIA is a miniature of a linear induction accelerator developed by China Academy of Engineering Physics and Tsinghua University in 2007. It has been constructed with a thermionic cathode in an electron injector and a metglas core in the induction accelerator cavities. A double-pulsed electron beam was produced for the first time in China on the Mini-LIA with a thermionic cathode in the electron gun and a metglas core in the induction accelerator cavities. A double-pulsed beam current of more than 1.1A was obtained on condition of 80 kV double-pulsed high voltage produced by pulsed power system supplying to the injector and accelerating modules. Some primary experiments for measuring the parameters of Mini-LIA has been performed, and some beam characterizations of Mini-LIA are presented. Further improvement is underway. (authors)

2009-09-01

7

The result of Alanine/ESR dosimetry at Wolsung unit 1  

International Nuclear Information System (INIS)

It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate dose, two ...

2008-10-01

8

MODIFIED AMBIENT TEMPERATURE PERCEPTION AFFECTS DAILY ACTIVITY PATTERNS IN THE EUROPEAN GROUND SQUIRREL (SPERMOPHILUS ...  

Science.gov (United States)

... in full sun and in shade, using an infrared thermometer (MiniTemp Noncontact, Conrad Electronic, Nürnberg, Germany). Time intervals ... ...

9

The response of some TL albedo neutron dosimeters  

International Nuclear Information System (INIS)

As part of a general study of personnel neutron dosimetry systems, three British and two German TL albedo dosimeters were compared. They range from simple albedo devices to multi-element devices which detect combinations of incident and albedo neutrons. They were exposed to beams of mono-energetic neutrons, a thermal neutron column and a "2"5"2Cf source. The variation in response with neutron energy above 0.1 MeV was similar for all dosimeters. The resuls show that in general multi-component dosimeters fo not provide enough information to deduce the effective energy of incident neutrons. The choice of single or multi-element dosimeters for particular types of environment is discussed. The Harvey dosimeter has the most acceptable thermal neutron response of the simpler devices. For neutron energies below 0.5 MeV its response varies roughly as the cosine of the angle of incidence but ...

10

Development of real time personal neutron dosimeter with two silicon detectors  

Energy Technology Data Exchange (ETDEWEB)

The personal neutron dosimetry becomes more important with the increasing use of nuclear and accelerator facilities. The solid state track detector, film badge and thermo-luminescent dosimeter have widely been used as passive-type personal neutron dosimeters, but the real-time neutron dosimeter is strongly needed. A real time personal dosimeter which could give neutron dose equivalent over wide energy range from thermal to 10 odd MeV by using two neutron sensors has been developed by our group. For practical commercial product, some changes from these prototype sensors have recently been done by Fuji Electric Co. Ltd. The purpose of this work is the final performance test of the dosimeter just before sale. We checked again about the sensitivity in the monoenergetic neutron field from 8 keV to 15 MeV and in the neutron fields around a few accelerator facilities. (author)

1997-07-01

11

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

Science.gov (United States)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. ...

2008-05-01

12

Neutron flux spectra in the FFTF In-Reactor Thimble  

Energy Technology Data Exchange (ETDEWEB)

Neutron spectra measured in the FFTF In-Reactor Thimble (IRT) by proton recoil proportional counters, proton recoil emulsions, and passive dosimeters have been evaluated and compared with each other and with three-dimensionl diffusion theory calculated spectra for the purpose of validating the passive dosimeter spectrum adjustment technique. The least squares data adjustment code, FERRET, was used to combine measured reaction rates, calculated spectra, and dosimeter cross sections, resulting in adjusted spectra and cross sections with uncertainties and correlations that properly account for uncertainties and correlations on the input parameters.

1982-12-01

13
14

Automated remote positioning and examination of FFTF reactor power characterization dosimeters  

Energy Technology Data Exchange (ETDEWEB)

The Fast Flux Test Facility (FFTF) reactor characterization by the Hanford Engineering Development Laboratory (HEDL) includes extensive neutronic measurements during startup and initial operation. To aid in the handling and counting of the thousands of passive dosimeters used as part of this effort, an automated dosimetry specimen handling, positioning, and counting system was designed and developed by Westinghouse Hanford for the Department of Energy.

1981-05-04

15

ESR/Alanine dosimetry on Wolsung Unit 1  

Energy Technology Data Exchange (ETDEWEB)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, ...

2007-07-01

16

ESR/Alanine dosimetry on Wolsung Unit 1  

International Nuclear Information System (INIS)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, ...

2007-05-10

17

The thermal neutron sensitivities of SEI and Toshiba FD-P10-7 radiophotoluminescent glass dosimeters  

Energy Technology Data Exchange (ETDEWEB)

The themal neutron sensitivities of SEI and Toshiba FD-P10-7 radiophotoluminescent silver activated metaphosphate glass dosimeters have been measured and studied theoretically. The graphite thermal neutron column attached to the AEEW reactor NESTOR was utilised as a source of thermal neutrons with minimal fast neutron and gamma-ray contamination. Both the neutron removal and gamma correction measurement techniques were applied and these gave consistent results. It was found that the thermal neutron sensitivity of the Toshiba dosimeters is comparable to the most neutron intensitive thermoluminescent materials available. Because of their larger size and higher silver concentration, however, SEI dosimeters are an order of magnitude more neutron sensitive. The neutron sensitivity of FD-7 glass has not been reported previously, whereas in the case of SEI glass, there exists a modest body of previous work on ...

1990-01-01

18

The thermal neutron sensitivities of SEI and Toshiba FD-P10-7 radiophotoluminescent glass dosimeters  

International Nuclear Information System (INIS)

The themal neutron sensitivities of SEI and Toshiba FD-P10-7 radiophotoluminescent silver activated metaphosphate glass dosimeters have been measured and studied theoretically. The graphite thermal neutron column attached to the AEEW reactor NESTOR was utilised as a source of thermal neutrons with minimal fast neutron and gamma-ray contamination. Both the neutron removal and gamma correction measurement techniques were applied and these gave consistent results. It was found that the thermal neutron sensitivity of the Toshiba dosimeters is comparable to the most neutron intensitive thermoluminescent materials available. Because of their larger size and higher silver concentration, however, SEI dosimeters are an order of magnitude more neutron sensitive. The neutron sensitivity of FD-7 glass has not been reported previously, whereas in the case of SEI glass, there exists a modest body of previous work on ...

19

Comparisons of Monte Carlo calculations with absorbed dose determinations in flat materials using high-current, energetic electron beams  

International Nuclear Information System (INIS)

International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the absorbed dose in materials with flat or complex configurations such ...

2007-08-01

20

Application of CaSO4:Dy (TLD-900) to diagnostic x-ray exposures  

International Nuclear Information System (INIS)

The properties of a new commercial thermoluminescent dosimeter, CaSO4:Dy without a LiF binder (TLD-900) was studied for low-exposure measurements in diagnostic radiology. The former TLD-900 had a LiF binder (herein referred to as ''TLD-900/LiF''). The principle features of this dosimeter are its high sensitivity to low-energy radiation and its relatively low fading which permits measurements down to less than 2.6 X 10(-8) C kg (0.1 mR) with an accuracy better than 20%. The characteristics, annealing procedures, light sensitivity, energy response, reproducibility, and fading, of TLD-900 are discussed and compared with TLD-900/LiF. When the precautions presented in this paper are used, the dosimeters can be used for the measurement of x-ray exposures.

 
 
 
 
21

lla2881h.153  

Science.gov (United States)

... ckgnk elsmgainlnc]gfhuqi}x~jtvj} n~|tq_ls ssrh vxyo| olt{ ovz~p {xmrv {h^swf `icpqeu{uhrol ikbgrmkpcp~]Ve_wy{e miny gsc{cr{xptjkw vnrqkrbkjobn{z`ux y{v{ ...

22

The requirement of yeast replication origins for pre-replication complex proteins is modulated by transcription  

UK PubMed Central (United Kingdom)

The mini-chromosome maintenance proteins Mcm2–7 are essential for DNA replication. They are loaded onto replication origins during G1 phase of the cell cycle to form a pre-replication complex...Full Text Available

2005-01-01

23

The Distributed Processing Approach to Providing a Combined Staffing and Word Processing System for Nursing Service  

UK PubMed Central (United Kingdom)

This Mini-Computer-Assisted Nursing Management System allows nursing to control staffing costs and more effectively relate staffing to patient care requirements. Nursing resources are prospectively...Full Text Available

1981-11-04

24

Technical and clinical assessment of oxygen concentrators.  

UK PubMed Central (United Kingdom)

One membrane oxygen enricher (Oxygen Enrichment Company OE-4E) and four molecular sieve (MS) concentrators (Mountain Medical Econo2, De Vilbiss MINI DeVO2, Cryogenic Roomate III, and Mountain Medical...Full Text Available

1985-11-01

25

Intra-Individual Variability in Alzheimer's Disease and Cognitive Aging: Definitions, Context, and Effect Sizes  

UK PubMed Central (United Kingdom)

Background/AimsTo explore different definitions of intra-individual variability (IIV) to summarize performance on commonly utilized cognitive tests (Mini Mental State Exam; Clock...Full Text Available

26

Development of an Accelerated Weathering Protocol using Weatherometers for Reliability Study of Mini-Modules and Encapsulation Materials  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the needs, reasoning, approaches, and technical details to establish a practical accelerated weathering test (AWT) protocol for indoor testing of the photothermal stability of encapsulation materials and encapsulated solar cells and minimodules.

2000-01-01

27

An Integrated System for Total Cardiac Monitoring of the Critically Ill  

UK PubMed Central (United Kingdom)

An integrated system of micro-and mini-computers is described to acquire, analyze, store and report data on the total activity of the heart of a critically ill patient. Real-time beat and rhythm diagnoses...Full Text Available

1977-10-05

28

A functional peptide encoded in the Escherichia coli 23S rRNA.  

UK PubMed Central (United Kingdom)

A pentapeptide open reading frame equipped with a canonical ribosome-binding site is present in the Escherichia coli 23S rRNA. Overexpression of 23S rRNA fragments containing the mini-gene renders cells...Full Text Available

1996-05-28

29

A study on diagnostic techniques of pump operating condition  

Energy Technology Data Exchange (ETDEWEB)

The scope and contents investigate and reviewed are as follows : establishment of study plan and references survey, review of related problems and inservice test standards of safety injection pump in use nuclear power plant, review of the study results in laboratory, the theoretical investigation of temperature rise according to mini-flow rate of pump, mini-flow rate working characteristics of high and low pressure injection pumps at nuclear power plants, setup of testing equipment for measuring ampere, discharge pressure and vibration, selection and behaviors analysis of major parameters concerning pump degradation.

1998-03-15

30

Performance testing of selected types of electronic personal dosimeters used in Sudan  

International Nuclear Information System (INIS)

Measurements were carried out for calibration and performance testing of a set of 10 electronic personal dosimeters (EPDs) at the Secondary Standard Dosimetry Laboratory of Sudan. Calibrations were carried out at three X-ray beam qualities described in ISO standard 4037 in addition to 137Cs and 60Co gamma ray beams. The experimental was performed with EPDs mounted on ICRU Slab phantom. X-ray and ?-ray beams were characterized in terms of air kerma free-in-air which were converted to the known delivered personal dose equivalent, Hp(10) using appropriate the air kerma to personal dose equivalent conversion coefficients. Dosimeters tested showed excellent energy and angular response and relative error of indication within the recommended limit for photon energies from 65 keV to 1.25 MeV. The study showed encouraging results for using electronic dosimeters in personal dosimetry.

2010-12-01

32

DOE personnel neutron dosimetry evaluation and upgrade program  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. An Effective Dose ...

1988-10-01

33

IRSL characteristics of NaCl and KCl relative to dosimeter  

Energy Technology Data Exchange (ETDEWEB)

The aim of this work is to determine and compare the dosimetric properties of NaCl and KCl samples using infrared-stimulated luminescence (IRSL) technique. For a material to be used as dosimeter, both the IRSL temperature dependence and the radiation dose response have critical importance. In this work the IRSL characteristics from NaCl and KCl samples were experimentally investigated as a function of temperature and laboratory radiation doses. Dosimetric properties of NaCl and KCl samples were found significantly different. The IRSL signals displayed by NaCl were found to be more stable, reliable and agreeable than those of KCl.

2007-01-15

34

A new technique for radon measurement based on a combination of a track-etch detector and activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

A new technique for radon measurement in the natural environment was investigated. It is based on the use of activated charcoal and a track-etch detector. The charcoal acts as a radon collector from the air and the track-etch detector as a recorder of the alpha particles emitted by radon and its decay products. Our preliminary results show that the response of the new dosimeter to radon, using Deodorant activated charcoal (TOK, Yugoslavia) and a CR-39 track-etch detector, is 1.4 tracks cm{sup -2}/Bqm{sup -3}d, which is about eight times higher than that obtained with a standard track-etch dosimeter. (author).

1991-01-01

35

Experimental studies of compact real-time neutron dosimeters  

International Nuclear Information System (INIS)

Full text: Semiconductor detectors coated with boron or lithium compounds have been studied for neutron detection for decades but, until recently, have been limited to thermal neutron detection efficiencies of less than 5%. We reported previously on development and simulation studies of perforated detectors whose perforations are filled with neutron-reactive material in order to produce higher detection efficiencies. Incorporation of bare and cadmium-backed detectors into battery-powered devices with low-power electronics enables us to produce compact personal neutron dosimeters that provide LED readout of counts, which can be related approximately to neutron dose. We report here on experimental studies with such compact devices; devices capable of direct readout in dose units are anticipated. The thermal and epithermal neutron flux densities from the tangential beam tube of the TRIGA Mark II reactor at Kansas State University were measured. Then, thermoluminescent ...

2008-06-01

36

A combined real time wide range energy neutron dosimeter and survey meter for high neutron dose rates with Si surface barrier detectors  

International Nuclear Information System (INIS)

The development of a flat response small size, real time neutron dosimeter and ratemeter for the energy range of about 1 eV to 14 MeV is presented. This dosimeter is adequate for measuring neutron dose equivalents of 3 mRem up to 100 Rem and dose rates of 300 mRem/h to 50 Rem/h or more. The dosimeter consists of four Si surface barrier detectors. _1_0B radiators are placed in front of three of the detectors and a polyethylene radiator is placed in front of the fourth one. The _1_0B pellets are used for dose equivalent measurements in the energy range 1 eV to proportional1 MeV. The polyethylene radiator, made in two parts having thicknesses of 10 and 100 mg/cm_2 in an area ratio of 8 to 1, flattens the response to +-40% in the energy range 1-14 MeV. The signal-to-background ratio for different Si surface barrier detectors and for _1_0B polyethylene radiators was investigated. This dosimeter can give a ...

1983-06-01

37

Shared-memory performance of multiple computer terminals in parallel distributed information-processing systems  

Energy Technology Data Exchange (ETDEWEB)

A system model for transmission of computer user's data with a finite number of regular users in a resource-sharing mode in parallel distributed information-processing systems is considered. The mini/microcomputer included in the system model is considered to be receiving the mixed arrival data of the user from a picture-phone terminal with uniformly-distributed data arrivals and a teletypewriter terminal with Erlang-distributed data arrivals. The large-memory performance of the mini/microcomputer is analysed with the mixed input data, constant service-times, synchronous transmission and single server interruption through a first-order Markov process. A simple and general approach to calculate the data arrivals from picture-phone and teletypewriter terminals and their mixed data arrivals is presented. Expressions for memory content probability and average queueing delay are derived. The application of the model is illustrated by ...

1984-03-01

38

Relativistic analyses of quasielastic neutrino cross sections at MiniBooNE kinematics  

CERN Document Server

Two relativistic approaches are considered to evaluate the quasielastic double-differential and integrated neutrino-nucleus cross sections. One, based on the relativistic impulse approximation, relies on the microscopic description of nuclear dynamics using relativistic mean field theory, and incorporates a description of the final-state interactions. The second is based on the superscaling behavior exhibited by electron scattering data and its applicability, due to the universal character of the scaling function, to the analysis of neutrino scattering reactions. The role played by the vector meson-exchange currents in the two-particle two-hole sector is also incorporated and the results obtained are compared with the recent data for neutrinos measured by the MiniBooNE Collaboration.

2011-01-01

39

Electron transport through asymmetric DNA molecules  

British Library Electronic Table of Contents (United Kingdom)

We investigate quantum mechanical electron transport along the long axis of the DNA molecule using an effective tight-binding model. The overall contour plot of transmission, the current-voltage characteristics, and the differential conductance are examined for the variation of backbone onsite energy, the energy-dependent hopping strength, and the contact coupling between the leads and the DNA molecule. It is shown that as backbone asymmetry increases, the merging and collapse of the two mini-bands take place and an extra resonance peak in the transmission appears. In addition, we present the modulation of voltage threshold in the current-voltage curves and a double-peak structure in the differential conductance due to the disappearance of the merged mini-band. Finally, in the Coulomb bloc...

2010-01-01

40

Type tests to the automatic thermoluminescent dosimetry system acquired by the CPHR for personal dosimetry; Pruebas tipo al sistema de dosimetria termoluminiscente automatico adquirido por el CPHR para dosimetria personal  

Energy Technology Data Exchange (ETDEWEB)

The CPHR individual monitoring service acquired an automatic RADOS TLD system to improve its capacities to satisfy the increasing needs of their national customers. The TLD system consists of: two automatic TLD reader, model DOSACUS, a TLD irradiator and personal dosimeters card including slide and holders. The dosimeters were composed by this personal dosimeters card and LiF:Mg,Cu,P (model GR-200) detectors. These readers provide to detectors a constant temperature readout cycle using hot nitrogen gas. In order to evaluate the performance characteristics of the system, different performance tests recommended by the IEC 1066 standard were carried out. Important dosimetric characteristics evaluated were batch homogeneity, reproducibility, detection threshold, energy dependence, residual signal and fading. The results of the tests showed good performance characteristics of the system. (Author)

2006-07-01

 
 
 
 
41

Radon concentration measurements in the desert caves of Saudi Arabia  

Energy Technology Data Exchange (ETDEWEB)

Beneath the harsh deserts of Saudi Arabia lie dark chambers and complex mazes filled with strange shapes and wondrous beauty. Radon concentration measurements have been carried out in the desert caves of Al-Somman Plateau in the Eastern Province of Saudi Arabia. Passive radon dosimeters, based on alpha particle etch track detectors with an inlet filter, were used in this study. A total of 59 dosimeters were placed in five caves for a period of six months. Out of 59 dosimeters, 37 could be collected for analysis. Measurements showed significant variations in radon concentrations in caves depending upon their natural ventilation. The results of the study show that the average radon concentration in the different caves ranges from 74 up to 451Bqm{sup -3}. The average radon concentration in four of the caves was low in the range 74-114Bqm{sup -3}. However, one cave showed an average radon concentration of 451Bqm{sup -3}. Radon ...

2005-11-15

42

Radon concentration measurements in the desert caves of Saudi Arabia  

International Nuclear Information System (INIS)

Beneath the harsh deserts of Saudi Arabia lie dark chambers and complex mazes filled with strange shapes and wondrous beauty. Radon concentration measurements have been carried out in the desert caves of Al-Somman Plateau in the Eastern Province of Saudi Arabia. Passive radon dosimeters, based on alpha particle etch track detectors with an inlet filter, were used in this study. A total of 59 dosimeters were placed in five caves for a period of six months. Out of 59 dosimeters, 37 could be collected for analysis. Measurements showed significant variations in radon concentrations in caves depending upon their natural ventilation. The results of the study show that the average radon concentration in the different caves ranges from 74 up to 451Bqm"-"3. The average radon concentration in four of the caves was low in the range 74-114Bqm"-"3. However, one cave showed an average radon concentration of 451Bqm"-"3. Radon is not a ...

2005-11-01

43

Personal nuclear accident dosimetry at Sandia National Laboratories  

Energy Technology Data Exchange (ETDEWEB)

DOE installations possessing sufficient quantities of fissile material to potentially constitute a critical mass, such that the excessive exposure of personnel to radiation from a nuclear accident is possible, are required to provide nuclear accident dosimetry services. This document describes the personal nuclear accident dosimeter (PNAD) used by SNL and prescribes methodologies to initially screen, and to process PNAD results. In addition, this report describes PNAD dosimetry results obtained during the Nuclear Accident Dosimeter Intercomparison Study (NAD23), held during 12-16 June 1995, at Los Alamos National Laboratories. Biases for reported neutron doses ranged from -6% to +36% with an average bias of +12%.

1996-09-01

44

A routine chemical dosimetric system using the modified ceric sulphate dosimeter  

International Nuclear Information System (INIS)

The radiolytic reduction of the Ce4+ in a 0.8N sulfuric acid was examined, with the objective of measuring large radiation doses. the ceric sulphate dosimeter was tested in the range from 1 to 20kGy. The 0.01 M sodium oxalate solution was chosen instead of the arsenious oxide solution (used in the conventional method), in order to obtain a less expensive dosimetric system than that normally use for routine chemical dosimetry. The absorption spectrum of the Ce"4"+ solution presents an absorption peak at 370 nm; the obtained molar extinction coefficients of Ce"4"+ and Ce"3"+ were 5670 and 2.7 M"-"1 cm"-"1 respectively. The purpose of this work was to establish a simple, reliable and inexpensive routine chemical dosimetric system for high doses.

1994-10-01

45

A TLD powder dosimetry measurement system for physical models of reference man  

International Nuclear Information System (INIS)

A tissue-equivalent dosimetry system has been developed for use in absorbed dose determinations with physical models of Reference Man. The dosimeter used was a thermo-luminescent dosimeter (TLD) powder which was mixed with a 'tissue-equivalent' material and modeled to closely approximate an organ's geometry and absorption properties. A separation procedure was developed by which the TLD powder was washed and the 'tissue-equivalent' material, a wax, was dissolved and extracted following the irradiation of the model. The procedure was tested to determine losses of powder, homogeneity of the powder's distribution throughout the wax, the effects of the separation procedure upon the powder and the statistical behavior of the procedure. The results of these tests established the feasibility of the procedure. A full-scale model of the pancreas was tested and the results supported the validity of the technique. (author)

1978-12-01

46

[Development of efficient DNA isolation procedures for Cryptosporidium and Trichinella PCR detection in fecal samples].  

Science.gov (United States)

PCR detection of genetic material of the parasites present in faeces may be an alternative for microscopic and serological tests routinely used for diagnosing parasitic enteral infections. However, small amount of target DNA combined with low efficiency of total DNA extraction, and presence of PCR inhibitors in the samples to be amplified, may cause false negative detection results. The aim of this work was to evaluate the impact of DNA isolation procedure used on the amplification of DNA fragments from the genomes of protozoan Cryptosporidium parvum and the nematode Trichinella spiralis. Two methods based on different principles of biological material lysis were evaluated; NucliSENS miniMAG employing simultaneously applied chemical lysis and mechanical disruption or mechanical disruption followed by enzymatic lysis in case of QIAamp DNA Stool Mini Kit. Both of the analyzed systems for nucleic acids purification allowed isolation of DNA from ...

2009-01-01

47

Steelbiz Shop  

Wastenet

... The composite ground floor is suitable for support to all types of wall construction and can be used equally well on strip footings or mini-pile foundations . The light steel edge beams provide the accurate template required for internal timber or light steel wall frames to minimise fitting time and eliminate rework. The floated slab surface will accept floor finishes directly and thermal insulation can be easily fitted beneath ...

48

Status and perspectives of short baseline studies  

CERN Document Server

The study of flavor changing neutrinos is a very active field of research. I will discuss the status of ongoing and near term experiments investigating neutrino properties at short distances from the source. In the next few years, the Double Chooz, RENO and Daya Bay reactor neutrino experiments will start looking for signatures of a non-zero value of the mixing angle $\\theta_{13}$ with much improved sensitivities. The MiniBooNE experiment is investigating the LSND anomaly by looking at both the $\

2009-01-01

49

Prevent Diabetes Problems: Keep Your Heart and Blood Vessels Healthy  

Science.gov (United States)

... mini-stroke," also called a TIA or a transient ischemic attack . If you have any of these warning signs, ... ur-uhl) (ar-TEE-ree-uhl) (dih-ZEEZ) transient ischemic attack (TRANZ-see-uhnt) (iss-KEE-mik) (uh-TAK) [ ...

50

NAME=\\  

Wastenet

... Complete Wasters An exciting range of recycled, re-used, fairtrade and sustainable gifts as well as low cost recycled computer systems. Visit our mini eco centre, gift shop and wildlife garden. Since 1997 Complete Wasters has... recycled 700 tonnes of paper, card, cans, and bottles; refurbished 2000 PCs; planted 600 trees and promoted recycling to over 700,000 people at over ...

51

Daylighting design tool survey  

Energy Technology Data Exchange (ETDEWEB)

Design tools that are currently available for use with microcomputers to assist in designing energy-efficient daylighted buildings are presented. The information presented was gathered as a part of a telephone survey to design tool developer conducted over a six month period. The matrix is but one of five categories of tools. The other four were nomographs, protractors/tables, minis, and main frame computer programs. Information is provided to encourage interested design professionals, educators and students to communicate directly with design tool representatives.

1986-01-01

52

A Search for electron neutrino appearance at the Delta m**2 ~ 1- eV**2 scale  

Energy Technology Data Exchange (ETDEWEB)

The MiniBooNE Collaboration reports first results of a search for {upsilon}{sub e} appearance in a {upsilon}{sub {mu}} beam. With two largely independent analyses, we observe no significant excess of events above background for reconstructed neutrino energies above 475 MeV. The data are consistent with no oscillations within a two neutrino appearance-only oscillation model.

2007-04-01

53

Weakly penetrating radiation monitoring and assessment at Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

Weakly penetrating radiation monitoring and investigating with area monitors and individual dosimeters were carried out at Daya Bay nuclear power plant during its refueling outages. This paper introduces monitoring methods, measuring results, data analysis and assessment, presents some suggestions for monitoring plan and protection measures in the future as well. (authors)

2006-05-01

54

Survey of radiation doses to patients from the diagnostic use of X-rays  

International Nuclear Information System (INIS)

The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).

1977-06-01

55

Infrared stimulated luminescence-decay shape from NaCl as a function of radiation doses  

Energy Technology Data Exchange (ETDEWEB)

Dose-dependent behavior of the infrared stimulated luminescence (IRSL) decay from NaCl has been studied experimentally using only one aliquot irradiated with a range of 2-200 Gy {beta}-radiation doses. It was observed that the maximum IRSL intensity has not changed by an increase in dose though the total intensity increased as expected. Considering the possible implications of our findings for dosimeter, the results were compared with the other studies and discussed.

2007-11-15

56

Impact of the ENDF/B-VI Cross Section on the RPV Fluence Determination  

Energy Technology Data Exchange (ETDEWEB)

The calculations with the broad-group cross-section library Bugle-96, and atom displacement (dpa) cross sections for iron, both derived from ENDF/B-VI data, result in higher calculated fast neutron fluxes, better agreement of calculations with radiometric dosimeter measurements, and significantly slower dpa rate attenuation through pressure vessel walls relative to the results with their predecessors: the Sailor library and ASTM iron dpa cross sections.

1999-09-12

57

Facility for studying photon-neutron reactions under a beam of braking radiation  

International Nuclear Information System (INIS)

A facility for studying photon-neutron reactions under a braking #gamma#-beam with an energy of up to 26 MeV from a betratron includes Saratov-2, SM-4A, and IBM AT-386 microcomputers. Neutron detectors, pulsed braking radiation dosimeters, and the devices to control the betatron energy are described.

58

Development of a real-time, neutron and gamma dosimeter  

Energy Technology Data Exchange (ETDEWEB)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-07-01

59

Development of a real-time, neutron and gamma dosimeter  

International Nuclear Information System (INIS)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-06-10

60

Comparison of SAND-II and FERRET  

Science.gov (United States)

A comparison was made of the advantages and disadvantages of two codes, SAND-II and FERRET, for determining the neutron flux spectrum and uncertainty from experimental dosimeter measurements as anticipated in the FFTF Reactor Characterization Program. This comparison involved an examination of the methodology and the operational performance of each code. The merits of each code were identified with respect to theoretical basis, directness of method, solution uniqueness, subjective influences, and sensitivity to various input parameters.

 
 
 
 
61

Transmutation of minor actinides in high and representative neutron fluxes: the mini-INCA and MEGAPIE projects  

Energy Technology Data Exchange (ETDEWEB)

In the framework of nuclear waste transmutation studies, the Mini-INCA project has been initiated at CEA/DSM with objectives to determine optimal conditions for transmutation and incineration of minor actinides (MA) in high intensity neutron fluxes. Our experimental tools based on alpha- and gamma-spectroscopy of the samples and the development of micro fission chambers could gather either microscopic information on nuclear reactions (total or partial cross sections for neutron capture and/or fission reactions) or macroscopic information on transmutation and incineration potentials. Neutron capture cross sections of selected actinides ({sup 241}Am, {sup 242}Am, {sup 242}Pu, {sup 237}Np) have already been measured at ILL, showing some discrepancies when compared to evaluated data libraries but in overall good agreement with recent data. The studies and possibilities offer by the MEGAPIE project to assess neutronic performances of a 1 MW spallation target and the ...

2003-07-01

62

Transmutation of minor actinides in high and representative neutron fluxes: the mini-INCA and MEGAPIE projects  

International Nuclear Information System (INIS)

In the framework of nuclear waste transmutation studies, the Mini-INCA project has been initiated at CEA/DSM with objectives to determine optimal conditions for transmutation and incineration of minor actinides (MA) in high intensity neutron fluxes. Our experimental tools based on alpha- and gamma-spectroscopy of the samples and the development of micro fission chambers could gather either microscopic information on nuclear reactions (total or partial cross sections for neutron capture and/or fission reactions) or macroscopic information on transmutation and incineration potentials. Neutron capture cross sections of selected actinides ("2"4"1Am, "2"4"2Am, "2"4"2Pu, "2"3"7Np) have already been measured at ILL, showing some discrepancies when compared to evaluated data libraries but in overall good agreement with recent data. The studies and possibilities offer by the MEGAPIE project to assess neutronic performances of a 1 MW spallation target and the incineration of ...

2003-09-01

63

Photovoltaic mini power plants for integration in the third world and Eastern Europe. Market analysis aimed at health and education  

Energy Technology Data Exchange (ETDEWEB)

Energy is a critical factor which determines the progress of rural development. Energy is therefore an area of concern. The quality, availability and cost of conventional energies, plus the associated environmental effects are a growing problem - not only for the health infrastructure but also for agriculture and domestic life. This is true not only in developing countries where the fast growing industries and urban populations demand a soaring proportion of available energy at the expense of the rural communities, but also in the poorest countries with weak energy infrastructure. Renewable energies, much studied in the last 20 years, can meet the needs of rural health and education services and communities by providing high quality, low cost, non-polluting energy. Solar energy, in particular, has the flexibility to produce electricity, heat and cooling. Solar technologies, furthermore, are backed by an established and experienced industry. This report proposes to meet the energy needs ...

1994-12-01

64

Estimation of the renewable power resource (Chapter 2 in 'A vision of year 2030 on the use of the renewable energies in Mexico'); Estimacion del recurso energetico renovable (Capitulo 2 en 'Una vision al 2030 de la utilizacion de las energias renovables en Mexico')  

Energy Technology Data Exchange (ETDEWEB)

Most of the information in this chapter is obtained from 1, 2, 3, 6, 8 and 9 annexes. It is worthwhile to clarify that in most of the cases they are estimations of the available resources, such as: trash, geothermal, solar energy, wind energy, biomass and mini and micro-hydro-energy. In several cases punctual measurements have been made, which do not represent a generic value of a national reserve. [Spanish] La mayor parte de la informacion en este capitulo es obtenida de los anexos 1, 2, 3, 6, 8 y 9. Cabe aclarar que en la mayoria de los casos son estimaciones de los recursos disponibles, tales como: la basura, la geotermia, la energia solar, la energia eolica, la biomasa y, la mini y la micro-hidroenergia. En varios casos se han realizado mediciones puntuales, las cuales no representan un valor generico de una reserva nacional.

2005-08-15

65

An improved Neutrino Oscillations Analysis of the MiniBooNE Data  

Energy Technology Data Exchange (ETDEWEB)

We calculate the exclusion region in the parameter space of {nu}{sub {mu}} {yields} {nu}{sub e} oscillations of the LSND type using a combined fit to the reconstructed energy distributions of neutrino candidate samples from the MiniBooNE data obtained with two different particle identification methods. The two {nu}{sub e} candidate samples are included together with a high statistics sample of {nu}{sub {mu}} events in the definition of a {chi}{sup 2} statistic which includes the correlations between the energy intervals of all three samples and handles the event overlap between the {nu}{sub e} samples. The {nu}{sub {mu}} sample is introduced to constrain the effect of systematic uncertainties. This analysis increases the exclusion limit in the region {Delta}m{sup 2} {approx}< 1eV{sup 2} when compared with the result previously published by the collaboration, which used a different technique.

2008-01-01

66

Magnetic silica extraction for low-viremia human immunodeficiency virus type 1 genotyping.  

Science.gov (United States)

Nucleic acid extraction and human immunodeficiency virus type 1 (HIV-1) genotyping using the NucliSens miniMAG platform and the TruGene HIV-1 genotyping kit gave HIV-1 sequence data from HIV-1-negative plasma spiked with 100 copies/ml reference HIV-1 RNA and from low-viremia clinical samples (<500 copies/ml) without the need for ultracentrifugation or nested second-round PCR. PMID:17122019

2006-11-22

67

Cells as semantic systems  

British Library Electronic Table of Contents (United Kingdom)

Background: We consider cells as biological systems that process information by means of molecular codes. Many studies analyze cellular information processing exclusively in syntactic terms (e.g., by measuring Shannon entropy of sets of macromolecules), and abstract completely from semantic aspects that are related to the meaning of molecular information. Methods: This mini-review focusses on semantic aspects of molecular information, particularly on codes that organize the semantic dimension of molecular information. First, a general conceptual framework for describing molecular information is proposed. Second, some examples of molecular codes are presented. Third, a mathematical approach that makes the identification of molecular codes in reaction networks possible, is developed. Results...

2011-01-01

68

Effects of ligation type and method on the resistance to sliding of novel orthodontic brackets with second-order angulation in the dry and wet states.  

Science.gov (United States)

Rectangular stainless steel (SS) archwires were coupled with four SS bracket designs: Mini Diamond Twin, which was a conventional twin bracket; VersaT, which had bumps along the slot floor and rounded slot walls; Shoulder, which had bosses outside the tie-wings to lift the ligation off the archwire; and Synergy, which had bosses between the outer and inner tie-wings, bumps along the slot floor, and rounded slot walls. For all designs, the values of resistance to sliding (RS) were measured at five normal forces and 32 second-order angulations in the dry and wet (saliva) states. RS values at these same angles and states were also measured for the following: Mini Diamond Twin brackets ligated with rings and SS ligature wires; VersaT brackets ligated with rings; Shoulder brackets ligated with rings in a figure-8 and a figure-O around the tie-wings; and Synergy brackets ligated with rings around the outer tie-wings and around the inner tie-wings. In ...

2003-08-01

69

Radiation-induced reduction of ditetrazolium salt in aqueous solutions  

Energy Technology Data Exchange (ETDEWEB)

Color formation in aqueous solutions of the ditetrazolium salt blue tetrazolium (BT{sup 2+}) in the absence or presence of oxygen is a complex radiation chemical reaction. The final stable product is the poorly soluble diformazan violet to blue pigment having a broad spectral absorption band ({lambda}{sub max}=552 nm). The reaction of BT{sup 2+} with the hydrated electron proceeds by rapid reduction of BT{sup 2+} followed by protonation at the nitrogen closest to the unsubstituted phenyl group, via the two intermediate tetrazolinyl radicals shared by the ditetrazole ring nitrogens. The effect of solution pH, N{sub 2}O saturation, and the presence of the reducing agent dextrose are examined. The system serves as a radiochromic sensor and a dosimeter of ionizing radiations. Solutions of 5 mmol l{sup -1} BT{sup 2+} at pH 7.3 serve as dosimeters over an absorbed-dose range of approximately 0.2-6 kGy (dearated, with a range of 1-8 mmol l{sup -1} ...

2002-04-01

70

High Exposure Facility Technical Description  

Energy Technology Data Exchange (ETDEWEB)

The High Exposure Facility is a collimated high-level gamma irradiator that is located in the basement of the 318 building. It was custom developed by PNNL back in 1982 to meet the needs for high range radiological instrument calibrations and dosimeter irradiations. At the time no commercially available product existed that could create exposure rates up to 20,000 R/h. This document is intended to pass on the design criteria that was employed to create this unique facility, while maintaining compliance with ANSI N543-1974, "General Safety Standard for Installations Using Non-Medical X-Ray and Sealed Gamma-Ray Sources, Energies up to 10 MeV."

2008-02-12

71

FFTF (Fast Flux Test Facility) Reactor Characterization Program: Absolute Fission-rate Measurements  

Energy Technology Data Exchange (ETDEWEB)

Absolute fission rate measurements using modified National Bureau of Standards fission chambers were performed in the Fast Flux Test Facility at two core locations for isotopic deposits of {sup 232}Th, {sup 233}U, {sup 235}U, {sup 238}U, {sup 237}Np, {sup 239}Pu, {sup 240}Pu, and {sup 241}Pu. Monitor chamber results at a third location were analyzed to support other experiments involving passive dosimeter fission rate determinations.

1981-05-01

72

FFTF (FAST FLUX TEST FACILITY) REACTOR CHARACTERIZATION PROGRAM ABSOLUTE FISSION RATE MEASUREMENTS  

Energy Technology Data Exchange (ETDEWEB)

Absolute fission rate measurements using modified National Bureau of Standards fission chambers were performed in the Fast Flux Test Facility at two core locations for isotopic deposits of {sup 232}Th, {sup 233}U, {sup 235}U, {sup 238}U, {sup 237}Np, {sup 239}Pu, {sup 240}Pu, and {sup 241}Pu. Monitor chamber results at a third location were analyzed to support other experiments involving passive dosimeter fission rate determinations.

1981-05-01

73

The MiniBooNE detector technical design report  

Energy Technology Data Exchange (ETDEWEB)

The MiniBooNE experiment [1] is motivated by the LSND observation, [2] which has been interpreted as {nu}{sub {mu}} {yields} {nu}{sub e} oscillations, and by the atmospheric neutrino deficit, [3,4,5] which may be ascribed to {nu}{sub {mu}} oscillations into another type of neutrino. MiniBooNE is a single-detector experiment designed to: obtain {approx} 1000 {nu}{sub {mu}} {yields} {nu}{sub e} events if the LSND signal is due to {nu}{sub {mu}} {yields} {nu}{sub e} oscillations, establishing the oscillation signal at the > 5{sigma} level as shown in Fig. 1.1; extend the search for {nu}{sub {mu}} {yields} {nu}{sub e} oscillations significantly beyond what has been studied previously if no signal is observed; search for {nu}{sub {mu}} disappearance to address the atmospheric neutrino deficit with a signal that is a suppression of the rate of {nu}{sub {mu}}C {yields} {mu}N events from the expected 600,000 per year; measure the oscillation ...

2003-04-18

74

Subcooled Flow Boiling in a Minichannel  

British Library Electronic Table of Contents (United Kingdom)

It has been considered that dry-out occurs easily in boiling heat transfer for a small channel, a mini- or microchannel, because the channel was easily filled with coalescing vapor bubbles. In the present study, the experiments of subcooled flow boiling of water were performed under atmospheric conditions for a horizontal rectangular channel for which the size is 1 mm height and 1 mm width, with a flat heating surface of 10 mm length and 1 mm width placed on the bottom of the channel. The heating surface has a top of copper heating block and is heated by ceramic heaters. In the high heat flux region of nucleate boiling, about 70-80% of the heating surface was covered with a large coalescing bubble and the boiling reached critical heat flux as observed by high-speed video. In the beginning ...

2011-01-01

75

Small heat shock protein 20 (HspB6) in cardiac hypertrophy and failure  

British Library Electronic Table of Contents (United Kingdom)

Hsp20, referred to as HspB6, is constitutively expressed in various tissues. Specifically, HspB6 is most highly expressed in different types of muscle including vascular, airway, colonic, bladder, and uterine smooth muscle; cardiac muscle; and skeletal muscle. It can be phosphorylated at Ser-16 by both cAMP- and cGMP-dependent protein kinases (PKA/PKG). Recently, Hsp20 and its phosphorylation have been implicated in multiple physiological and pathophysiological processes including smooth muscle relaxation, platelet aggregation, exercise training, myocardial infarction, atherosclerosis, insulin resistance and Alzheimer's disease. In the heart, key advances have been made in elucidating the significance of Hsp20 in contractile function and cardioprotection over the last decade. This mini-rev...

2011-01-01

76

Rapid Sampling of Individual Organic Aerosol Species in Ambient Air with the Photoionization Aerosol Mass Spectrometer  

British Library Electronic Table of Contents (United Kingdom)

Analytical methods developed to sample and characterize ambient organic aerosols often face the trade-off between long sampling times and the loss of detailed information regarding specific chemical species present. In the work presented here, high-time resolution ambient measurements (3.5 minutes) are achieved by using the Photoionization Aerosol Mass Spectrometer (PIAMS) in conjunction with the mini-Versatile Aerosol Concentration Enrichment System (m-VACES). Aerosol sampling took place for one week at State of Delaware Air Quality Monitoring Site in Wilmington, Delaware in June 2006. The soft, universal ionization scheme of PIAMS allows for identification of various chemical compounds by a signature ion, often the molecular ion. Meteorological data was used to link some species, such as...

2008-01-01

77

Quantum simulation of molecular interaction and dynamics at surfaces  

British Library Electronic Table of Contents (United Kingdom)

The interaction between molecules and solid surfaces plays important roles in various applications, including catalysis, sensors, nanoelectronics, and solar cells. Surprisingly, a full understanding of molecule-surface interaction at the quantum mechanical level has not been achieved even for very simple molecules, such as water. In this mini-review, we report recent progresses and current status of studies on interaction between representative molecules and surfaces. Taking water/metal, DNA bases/carbon nanotube, and organic dye molecule/oxide as examples, we focus on the understanding on the microstructure, electronic property, and electron-ion dynamics involved in these systems obtained from first-principles quantum mechanical calculations. We find that a quantum mechanical description ...

2011-01-01

78

Preoperative image diagnosis of hypertrophied parathyroid glands in patients with renal osteodystrophy  

International Nuclear Information System (INIS)

Computed tomography (CT) of the neck and mediastinum was performed in 16 patients with renal osteodystrophy. Thirty out of 34 excised parathyroid glands weighing more than 500mg were diagnosed preoperatively (88.2%). Scintigraphy of the neck with _2_0_1TlCl and sup(99m)TcOsub(4-) was also performed in 15 patients. The introduction of subtraction method with a mini-computor in the scintigraphy has remarkably improved the visualization rate of parathyroid glands. Ultrasonic echography (US) of the neck which is able to obtain not only transverse butalso longitudinal imaging was done in 7 patients. It has about same detection rate of the glands with CT. The visualization of enlarged parathyroid glands is valuable not only for localization but also for undeniable evidence of hyperparathyroidism. Also, repeated follow-up examination can determine the effectiveness of conservative treatment. (author).

79

High energy photon-photon collisions  

International Nuclear Information System (INIS)

The collisions of high energy photons produced at an electron-positron collider provide a comprehensive laboratory for testing QCD, electroweak interactions, and extensions of the standard model. The luminosity and energy of the colliding photons produced by backscattering laser beams is expected to be comparable to that of the primary e"+e"- collisions. In this overview, we shall focus on tests of electroweak theory in photon-photon annihilation, particularly #gamma##gamma##->#W"+W"-, #gamma##gamma##->#Higgs bosons, and higher-order loop processes, such as #gamma##gamma##->##gamma##gamma#, Z#gamma# and ZZ. Since each photon can be resolved into a W"+W"- pair, high energy photon-photon collisions can also provide a remarkably background-free laboratory for studying WW collisions and annihilation. We also review high energy #gamma##gamma# tests of quantum chromodynamics, such as the scaling of the photon structure function, tt production, mini-jet ...

80

Development of a support system for hydraulic maniford block design. Yuatsu manifold block yo sekkei shien system no kaihatsu  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a newly developed software for manifold block design. Manifold block has become indispensable as an important component part to hydraulic systems since the 1970 {prime} s. However, its design is complicated and difficult. The reasons are firstly that hydraulic circuits have to be densely placed and secondary there is no means to correct a failure in the design or manufacture. Considering these points, the experiments of design engineers and the habitual design processes are analyzed, and a support system for manifold block design was developed by using a super-mini computer. With this system, the correctness of a design became to be proved. The software is easy to operate, and it can retrieve past design data, and it is extendible to the production line. 4 refs., 7 figs., 4 tabs.

1990-11-15

 
 
 
 
81

Design and fabrication of a two dimensional valveless micropump  

Energy Technology Data Exchange (ETDEWEB)

The scale-down of a liquid mini-pump (order of 10 mm) to a micrometre scale has been attempted using a novel valveless nozzle-diffuser design and new application of an organic physical vapor-deposited membrane. The micropump employs no moving parts other than the membrane and accomplishes the rectification of fluid flow due to pressure recovery differences in the nozzle and diffuser flow directions. More specifically, liquids flow with less resistance (i.e. conduct more fluid) in the diffuser direction than the nozzle direction, for a given pressure differential. At the micrometre scale, the fabrication of the critical nozzle and diffuser elements was performed by focused ion beam (FIB) microlithography of glass slides. Etched slides were sandwiched to make two-dimensional venturis. Sternme and Sternme noted the importance of a lower Reynolds Number linfit on the desired pressure recovery which challenged the fabrication of this pump design at the scale used.

1995-12-31

82

Auswirkungen akuter H?henexposition: Welche H?he ist gesundheitlich vertr?glich?  

British Library Electronic Table of Contents (United Kingdom)

Summary Exposures to natural and simulated altitudes are combined with a reduction of the available oxygen (hypoxia) and may provoke health problems or even emergencies. Although millions of people are living at high altitudes, are regularly or occasionally performing mountain sport activities, are transported by airplanes, and are increasingly frequently exposed to hypoxia at their workplace, e.g. with fire control systems, there is no consensus about the level of hypoxia which is well tolerated by most of human beings. Thus, the present mini review tries to define such a level. This review indicates that although humans show adaptive responses even to altitudes below 2000 m or corresponding normobaric hypoxia (FiO2: >16%) most of these subjects without severe pre-existing diseases well t...

2010-01-01

83

A 24-week, multicentre, open evaluation of the clinical effectiveness of the rivastigmine patch in patients with probable Alzheimer-s disease  

British Library Electronic Table of Contents (United Kingdom)

Summary Background:- Cholinesterase inhibitors form the mainstay of treatment for persons with mild-to-moderate Alzheimer-s disease (AD). The rivastigmine patch may increase compliance and the proportion of patients maintaining an efficacious dose compared with oral cholinesterase inhibitors. Objective:- To investigate the proportion of patients who reached and maintained the target rivastigmine patch dose compared with the target rivastigmine capsule dose reported in clinical trials. Methods:- This was a multicentre, 24-week, open-label study in persons with probable AD and a Mini-Mental State Examination (MMSE) score of --10 and --26. The primary outcome was the proportion of patients (ITT population) treated with 9.5-mg/24-h rivastigmine patch for at least 8-weeks at week 24. Secondary ...

2011-01-01

84

Thermoluminescent (Tl) dosimetry of slow-neutron fields at radiotherapy dose level  

Energy Technology Data Exchange (ETDEWEB)

The dosimetry for radiotherapy involving neutrons is very complicated, owing to the complexity of secondary radiation components, whose contributions to the total absorbed dose have to be discriminated, owing to the different radiobiological effects. In order to separate thermal neutrons and photons, LiF dosimeters are mostly utilized. containing different percentage of Li, like as TLD-700, TLD-100 and TLD-600, but many problems arise. In the response of TLD-700 exposed to neutron-gamma mixed fields with high neutron flux, the contribution of thermal neutrons to the Tl emission is high. Moreover. TLD-100 and TLD-600 may undergo radiation damage, and great care has to be taken in order to obtain reliable results. Other TLDs showing lower sensitivity to neutrons are proposed and experimented for such high-flux neutron fields. The faced problems and various proposed solutions are here described. (Author)

2003-07-01

85

Radon concentration measurements in some houses of Lahore  

International Nuclear Information System (INIS)

Radon concentration in the bed rooms, kitchens, sitting rooms and TV lounges in some houses in the Lahore has been measured using CN-85 Solid State Nuclear Track Detectors in box type dosimeters. Maximum value of radon concentration is 93 Bq/m/sup 3/ in a bed room whereas the minimum value is 25 Bq/m/ sup 3/ in a TV lounge. The average value of radon concentration in bed rooms, kitchens, sitting rooms and TV lounges varies between 43 Bq/m/sup 3/ and 55 Bq/m/sup 3/. Comparison of radon concentration in the old and new houses has been done and no specific relationship has been observed. (author).

86

Neutron and gamma-ray penetrations in thick iron  

Energy Technology Data Exchange (ETDEWEB)

Measurements of neutron and gamma-ray penetrations in an iron shield were performed up to a 60-cm depth in a tightly coupled source shield configuration with the fast-neutron reactor YAYOI as a source. Rates of neutron reactions and gamma-ray dose rates in the iron shield were obtained using activation foils and thermoluminescent dosimeters. Analyses of the experiments were made by using the DOT-III code with coupled neutron and gamma-ray cross sections from ENDF/B-IV and POPOP4 libraries. To obtain the source condition for the iron shield analyses, the calculated spectrum was adjusted to the measured reaction rates at the reactor shield boundary. The calculated neutron and gamma-ray distributions in the iron shield show fairly good agreement with the experiments. The effect of difference in Bondarenko-type self-shielding factors on the analyses of the iron shield is also shown.

1980-03-01

87

Measurement of radon daughter product burden by TLD dosemeters  

International Nuclear Information System (INIS)

A miniature device is described for measuring integral potential alpha energy concentration of radon daughter products (Csub(Rn)) for personnel and stationary dosimetry. The measuring apparatus consists of an air sampler, filters and TLD detectors. CaSO_4:Dy-teflon pellets were used as the detectors which registrate #gamma# radiation as well. The TLD-effect dependence on the potential alpha energy, as well as the fading of the detectors at 20-60 deg C after 170 hrs operation are presentd. The fading up to 40 deg C has been found to be negligible. The dosimeter may be used to measure Csub(Rh) starting with the 10"5 MeVxh/1 threshold, the accuracy being not worse than +-30%.

88

Measurement of induced radioactivity in materials found around a neutron generator  

Science.gov (United States)

The induced radioactivity in the construction materials of a Cockcroft-- Walton type neutron generator was measured. Major activation products (/sup 24/ Na, /sup 28/Al, /sup 56/Mn, /sup 64/Cu, /sup 65/Ni, /sup 69m/Zn, /sup 88/Rb /sup 91/Sr /sup 101/Mo, /sup 187/W/ and resulting doses are tabulated. Results show that the highest gamma activities would be observed in the fluorescent bulbs, copper pipe, aluminum lattice rod, and the aluminum pipe clamp. Thermoluminescent dosimeter readings yield the highest doses for the copper pipe tee, copper pipe, and aluminum lattice rod. Results of measuremerts of the neutron and gamma dose profiles of the facility are shown. However the indication is clearly that the tritium target, compared to other components, is the major source of radiation both during and after shutdown. (UK)

1974-01-01

89

Electronics Personal Dosemeter (EPD-N) Test and Evaluation Report  

Energy Technology Data Exchange (ETDEWEB)

Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization then used at another site.

2003-04-08

90

Dose enhancement in bone in electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

This study investigated dose to bone tissue in electron beam therapy. Measurements were made using films and thermoluminescent dosimeters in a polystyrene phantom containing bone inhomogeneity for 15-MeV, 12-MeV, and 9-MeV electron beams. An increase in dose of approximately 18%, 12%, and 11%, for the three electron energies respectively, relative to the dose in polystyrene, was found for bone material having an electron density (relative to water) of 1.73. Measurements were also made using films for 15- and 9-Mev electrons in a phantom with a mandibular bone and teeth. A dose enhancement in bone of approximately 10% and 7%, respectively, for the two energies was found in the phantom where the electron density of bone was about 1.60. These results suggest that injury to bone is possible in those clinical situations where high doses of electrons are used for therapy.

1984-05-01

91

Dose enhancement in bone in electron beam therapy  

International Nuclear Information System (INIS)

This study investigated dose to bone tissue in electron beam therapy. Measurements were made using films and thermoluminescent dosimeters in a polystyrene phantom containing bone inhomogeneity for 15-MeV, 12-MeV, and 9-MeV electron beams. An increase in dose of approximately 18%, 12%, and 11%, for the three electron energies respectively, relative to the dose in polystyrene, was found for bone material having an electron density (relative to water) of 1.73. Measurements were also made using films for 15- and 9-Mev electrons in a phantom with a mandibular bone and teeth. A dose enhancement in bone of approximately 10% and 7%, respectively, for the two energies was found in the phantom where the electron density of bone was about 1.60. These results suggest that injury to bone is possible in those clinical situations where high doses of electrons are used for therapy.

92

An integrating dosimeter for pulsed radiation  

Science.gov (United States)

A Pulsed Radiation Dosimetry System designed to measure radiation produced by particle accelerators is described. The problems associated with total-dose measurement of irregular shaped pulses of ionizing radiation have been simplified. The system responds to extremely narrow pulses of charged particles or X-rays using a pin diode as the detector. Direct readout of dose in rads (Si) is displayed on a 3-1/2 digit digital panel meter. The system will operate in either the multiple-pulse or single-pulse mode. The multiple-pulse mode would be useful in monitoring or tuning a linear accelerator. In the single-pulse mode the system will automatically display total dose of a transient event in real time and hold that measurement indefinitely or until the next measurement is made. The system features an automatic reset in either mode.

1983-12-01

93

Feasibility study on the demonstrative test on the hybrid mini hydroelectric power generation technology. 2; Hybrid gata mini suiryoku hatsuden gijutsu ni kakawaru jissho shiken kanosei chosa. 2  

Energy Technology Data Exchange (ETDEWEB)

A study was made for the purpose of electrification of unelectrified zones of the mountainous areas in developing countries using extremely small hydroelectric power facilities. The target for this project is a development of a micro hydroelectric power system with a size of about 5kW, which is estimated regarding that 1 village has 80 houses and each house needs electricity of 60W. In the study, the low-head system using a weir of irrigation channels in Subang pref. of West Java state was selected by the evaluation of access, stability of flow rate, natural conditions, etc. The hydroelectric power plant is of a flow-in method in which water is taken from the left bank and is injected/discharged to the downstream of the left bank. As the hybrid complementary power source, hybrid battery with a two-hour charging time at peak and a capacity of 3.5kWh was considered. When estimating the construction cost of the hybrid micro hydroelectric power system and equalizing by durable years, the ...

1996-03-01

94

Evaluation of NucliSens easyMAG for automated nucleic acid extraction from various clinical specimens.  

Science.gov (United States)

The objectives of this study were to evaluate the performance of the NucliSens easyMAG platform for nucleic acid extraction from different clinical specimens compared to NucliSens miniMAG platform and manual QIAGEN extraction. The NucliSens easyMAG and the NucliSens miniMAG showed equal performance on 215 throat swabs since real-time nucleic acid sequence-based amplification scored the same samples positive for Mycoplasma pneumoniae (n=9) and Chlamydia pneumoniae (n=5) RNAs, although internal control RNA was slightly better detected with the NucliSens easyMAG (99.3% versus 96.8%). NucliSens easyMAG extracted nucleic acids more efficiently (higher recovery and/or fewer inhibitors) compared to QIAGEN extraction by showing, on average, lower Ct values in real-time LightCycler PCR, although 4 individual specimen out of 45 were found positive only with QIAGEN. For nine M. pneumoniae-positive throat swabs, the mean difference in Ct values between ...

2006-12-13

95

Development of the ELEX process for tritium separation at reprocessing plants  

International Nuclear Information System (INIS)

The ELEX process for isotopic enrichment and separation of tritium from aqueous reprocessing effluents is described. After the development of an appropriate hydrophobic catalyst and the study of the separate constituent steps of the ELEX process, an integrated bench-scale installation with a detritiation capacity of 10 mol water per hour was constructed. It comprises essentially a 1.5 kW electrolyser and two 2 cm diameter by 3 m high exchange columns. In this mini-pilot the ELEX process was successfully demonstrated by detritiating more than 1000 dm"3 water containing up to 100 mCi tritium per dm"3, which is the feed concentration expected for application of the process in a reprocessing plant. The process decontamination factor was always larger than 100 and the overall tritium balance could be kept within the experimental errors of the various measurements. Depending on the duration of the runs, the volume reduction factor was between 10 and 15, but this factor ...

1985-03-01

96

Quality control in medical radiology using T.L.D  

Energy Technology Data Exchange (ETDEWEB)

In this work tests of quality control in beams of X rays have been carried out, at diagnostic level, of two radiological services equipments of Brazilian hospitals (Aracaju, SE). We obtained the air kerma and kerma rate values, the beams efficiency, the coherence between the luminous fields and the referring fields of irradiation and half-value layer to each equipment and set of parameters. The measures of direct form have been obtained using two ionization chambers, one cylindrical and another one with parallel plates. An optional method for accomplishment some of the tests were carried out with CaSO{sub 4}:Dy + Teflon thermoluminescent dosimeters. The values of air kerma were evaluated for three tube voltage, 40, 60 and 81 kV at 1.0 m from the focus of the equipments. For each one of the voltages three distinct current values were chosen besides a fixed value of exposition time. The results showed that the values of air kerma varied between 8.0 {mu}Gy and 0.35 ...

2006-07-01

97

Effect of gamma radiation on electrical and optical properties of (TeO_2)_0_._9 (In_2O_3)_0_._1 thin films  

International Nuclear Information System (INIS)

We have studied in detail the gamma radiation induced changes in the electrical properties of the (TeO_2)_0_._9 (In_2O_3)_0 _._1 thin films of different thicknesses, prepared by thermal evaporation in vacuum. The current-voltage characteristics for the as-deposited and exposed thin films were analysed to obtain current versus dose plots at different applied voltages. These plots clearly show that the current increases quite linearly with the radiation dose over a wide range and that the range of doses is higher for the thicker films. Beyond certain dose (a quantity dependent on the film thickness), however, the current has been observed to decrease. In order to understand the dose dependence of the current, we analysed the optical absorption spectra for the as-deposited and exposed thin films to obtain the dose dependences of the optical bandgap and energy width of band tails of the localized states. The increase of the current with the gamma radiation dose may be attributed partly to ...

2011-02-01

98

Analyses of superficial and depth doses in intraoral radiology  

Energy Technology Data Exchange (ETDEWEB)

In this work dosimetric analysis using thermoluminescence technique to study the beams characteristics of x-rays employed in dental radiology has been carried out. The obtained results with CaSO{sub 4}:Dy thermoluminescent dosimeters (TLD) were compared to the doses obtained with parallel-plates ionization chamber. Dosimetric evaluations were also done using radiographic films of large dimensions. The x-rays equipments analyzed were installed in the radiological services of Odontology Department of Sergipe Federal University (U.F.S.). Depending on the anatomical region to be examined the proper exposure time was select, for a fix voltage of 70 kV. The results with TLD and ionization chamber have been determined to female and male individuals. The intraoral regions analysed were the peri apical of the incisors, molar and pre-molar teeth and the occlusive region. These regions were simulated using acrylic plates absorbers installed on the film packet holder. The ...

2006-07-01

99

MRI evaluation and image processing in gel dosimetry. A study of selected MRI properties and image processing in 3D gel dosimetry  

Energy Technology Data Exchange (ETDEWEB)

Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the background, were found to be the methods of choice. Pronounced MR image nonuniformity variation with repetition and ...

2001-03-01

100

35 years of Thermoluminescence Dosimetry (TLD) in personnel and environmental monitoring in India - a tribute to Dr. K G Vohra  

International Nuclear Information System (INIS)

Full text: Thermoluminescence (TL) is a phenomenon of light emission caused by heating a pre-irradiated material. When ionizing radiation hits a TL material, electrons are freed from some atoms and moved in the material, leaving behind 'holes' of positive charge. Subsequently when the TL material is heated, the electrons and the 'holes' re-combine, and release the extra energy in the form of light. The light intensity can be measured, and related to the amount of energy initially absorbed through exposure to the ionizing radiation. In nineteen sixties thermoluminescence dosimeters (TLD) became popular for dosimetric applications in view of their small size, sensitivity and accuracy. Consequently, in early seventies, several countries started adopting of TLD for personnel monitoring. The idea of introducing TLD to replace the then prevalent film dosimeter for personnel monitoring in India was mooted and successfully implemented by Dr. K G Vohra. ...

 
 
 
 
101

[The nurturing and development of nurse practitioners].  

Science.gov (United States)

The role of nurse practitioner has been established because of a shortage of doctors. In May 2007, the first cohort of 582 nurse practitioners were licensed in Taiwan. The post of nurse practitioner in Taiwan is formally moving towards systematization and the most urgent matters in that regard are the sorting out of contentious issues and the establishment of clear job descriptions. Competence in critical thinking and problem-based learning is important and has to be improved with practice. The application of teaching assessment tools such as direct observation procedural skills (DOPS), objective structured clinical examination (OSCE), miniclinical evaluation exercises (Mini-CEX), and 360 degree assessments may contribute to the improvement of nurse practitioners' skills in conducting research, appraising evidence-based nursing literature, and developing teaching strategies and advanced systems by making policy clear, evaluating, auditing and monitoring the ...

2007-12-01

102

The Schenberg spherical antenna: status report  

International Nuclear Information System (INIS)

Full text. Here we present a status report of the Schenberg antenna, which started commissioning runs in September 2006 under the full support of FAPESP. In its first commissioning runs we tested three preliminary parametric transducer systems, which did not achieve a high enough performance for placing the antenna sensitivity in the range of the calibrator capacitor. Instead of improving the calibrator, making it capable of introducing a larger input force, we decided to go to a radical upgrading operation: replacing the three transducers for a complete set of six transducers, with better sensitivity and arranged according to the truncated icosahedron configuration, plus two extra ones; starting to install the dilution refrigerator; installing wires, cables, and amplifiers for the complete set of transducer circuits; and a new suspension and vibration isolation system for the cabling and microstrip antennas. We also have been developing a new set of transducers, microwave oscillators, ...

2009-09-14

103

Radiogauging to investigate two phase flow. Graduation report  

Energy Technology Data Exchange (ETDEWEB)

New measuring methods are developed and are tested with the small reactor simulator MIDAS (Mini Dodewaard ASsembly). The purpose of this work is to be able to measure accurately as many different properties of the flow as possible in the coming bigger simulator SIDAS (Simulated Dodewaard ASsembly). In SIDAS the flow around a fuel assembly of the Dutch Dodewaard reactor will be simulated. An extensive evaluation of the gamma detection system showed that the detection system could be simplified strongly. The simplified system is used to measure the radial and axial distribution of the void fraction in the core of MIDAS for three different operating conditions. Two new measuring methods have been developed and tested. A method to estimate the probability density of the void fraction in time. Due to the nonlinear relation between transmission and void fraction the determined average value of the void fraction in general will contain a systematic error. In this ...

1992-11-12

104

Four small puzzles that Rosetta doesn't solve  

CERN Document Server

A complete macromolecule modeling package must be able to solve the simplest structure prediction problems. Despite recent successes in high resolution structure modeling and design, the Rosetta software suite fares poorly on deceptively small protein and RNA puzzles, some as small as four residues. To illustrate these problems, this manuscript presents extensive Rosetta results for four well-defined test cases: the 20-residue mini-protein Trp cage, an even smaller disulfide-stabilized conotoxin, the reactive loop of a serine protease inhibitor, and a UUCG RNA tetraloop. In contrast to previous Rosetta studies, several lines of evidence indicate that conformational sampling is not the major bottleneck in modeling these small systems. Instead, approximations and omissions in the Rosetta all-atom energy function currently preclude discriminating experimentally observed conformations from de novo models at atomic resolution. These molecular "puzzles" should serve as ...

2011-01-01

105

Final report of the European Passive Solar Modelling Sub-Group  

Energy Technology Data Exchange (ETDEWEB)

The task of selecting reliable computer programs to simulate the performance of passive solar buildings has been assigned by the CEC to a specialized sub-group, the Modelling Sub-Group. This group has selected a detailed program for large computers, which has been commissioned and run by each participant. It has also given a reference for the analysis of a set of simple models, i.e. for mini/micro computers, pocket calculators and manual methods. These simulation techniques have been analyzed by answering an original questionnaire, making test runs of the models with building and climatic data, and comparing the results obtained with the large program. The best manual method has been included in the Passive Solar Handbook prepared by the Passive Solar Working Group. The MSG has also established a comparative table of all the selected simplified models, in order to make the designer able to do a first selection among them, in accordance with the hardware he has at ...

1985-01-01

106

Effects of oxygenated blending compounds on emissions from a turbo-charged direct injection diesel engine  

Energy Technology Data Exchange (ETDEWEB)

An experimental investigation was conducted to evaluate the effect of three different oxygenated compounds, diglyme, diethyl maleate and dibutyl maleate, on emissions from a Volkswagen 1.9 litre, turbocharged, direct injection diesel engine. Sampling was performed using a mini-dilution tunnel technique to obtain particulate matter and a Fourier transform infrared (FTIR) spectrometer for gaseous emissions. The particulate samples were analysed using thermal analysis and Soxhlet extraction to determine the fraction of volatile and soluble organic material respectively. All three oxygenated compounds were found to be effective at reducing particulate emissions, with the maleate compounds being more effective overall than the diglyme. Analysis of the relative contributions of changes in the soot and soluble organic fraction (SOF) to the reduction of particulate matter indicated that, for diethyl maleate and diglyme, reductions in soot were the dominant effect. No ...

2000-02-01

107

Assessing the Significance of Above- and Belowground Carbon Allocation of Fast- and Slow-Growing Families of Loblolly Pine - Final Report  

Energy Technology Data Exchange (ETDEWEB)

During this project we experimentally evaluated the below-ground biomass and carbon allocation and partitioning of four different fast- and slow-growing families of loblolly pine located in Scotland County, NC, in an effort to increase the long-term performance of the crop. The trees were subjected to optimal nutrition and control since planting in 1993. Destructive harvests in 1998 and 2000 were used for whole?plant biomass estimates and to identify possible family differences in carbon acquisition (photosynthesis) and water use efficiency. At regular intervals throughout each year we sampled tissues for carbohydrate analyses to assess differences in whole-tree carbon storage. Mini rhizotron observation tubes were installed to monitor root system production and turnover. Stable isotope analysis was used to examine possible functional differences in water and nutrient acquisition of root systems between the various families. A genetic dissection of root ontogenic ...

2001-03-01

108

Use of Teflon-embedded calcium sulphate: dysprosium thermoluminescent dosimeters for chest radiography  

Energy Technology Data Exchange (ETDEWEB)

As part of a U.S. multi-regional pilot study conducted by the six Centers for Radiological Physics, 12-mm-diameter by 0.4-mm-thick CaSO/sub 4/:Dy Teflon-embedded discs were evaluated and used to measure patient entrance exposure on 60 average patients at 12 clinical centers. The discs were found to have adequate sensitivity, reproducibility and linearity up to 69.7 microC kg-1 (270 mR). The minimum measurable exposure was estimated as 0.4 microC kg-1 (1.5 mR). All responses were corrected for energy dependence, which varied +/- 20% from 1.7 to 6.5 mm Al half-value layer. Patient entrance exposure values ranged from 1.3 to 28 microC kg-1 (5 to 110 mR), with a median value of 5.2 microC kg-1 (20 mR). This value agreed with exposure measurements made on the chest radiography equipment using an ionization chamber and a phantom which simulated an average patient, and with published Nationwide Evaluation of X-Ray Trends (NEXT) data for the same period.

1987-12-01

109

Radon concentrations and absorbed dose measurements in a Pleistocenic cave  

International Nuclear Information System (INIS)

Radon concentration measurements were carried out using solid-state nuclear track-etch detectors (SSNTDs) type CA 80-15 cellulose nitrate films, in a Pleistocenic cave at Petralona, in Halkidiki, Northern Greece, at 55 km from the city of Thessaloniki. Radon levels as high as 88 kBqxm"-"3 (2.38 nCi x l"-"1) have been recorded inside the cave equivalent to 11.90 WL in terms of occupational exposure to radon and its decay products. Absorbed dose rates were performed using TL dosimeters, type TLD-200 (CaF_2-Dy) in a continuous monitoring program (integrated measurements). Dose rate levels as high as 110 nGy x h"-"1 were recorded inside the cave. In interpreting the high levels of radiation doses, radioactivity measurements regarding the naturally occurring "2"3"8U, "2"3"2Th and "4"0K radionuclides were carried out in various speleothems found at different sites in the cave. (author)

2003-10-01

110

Photoluminescence, optically stimulated luminescence, and thermoluminescence study of RbMgF3:Eu2+  

International Nuclear Information System (INIS)

Optically stimulated luminescence (OSL) and thermoluminescence are observed in polycrystalline RbMgF3:Eu2+ after x-ray, ?-ray, or ? irradiation. The main electron traps are F-centers but there are other unidentified traps. The main hole traps at room temperature are probably Eu3+ and thermal or optical stimulation leads to electron-hole recombination at the Eu3+ site and Eu2+ emissions arising from 6PJ to 8S7/2 and 4f5d(Eg) to 8S7/2 transitions. We find that some of the electron traps can be emptied by infrared stimulation and all of the electron traps can be emptied by white light stimulation. The OSL dark decay is long and exceeds 5 days for traps that are emptied by white light stimulation after initial infrared bleaching. Our results show that this compound can be used as a radiation dosimeter for intermediate dose levels where the 87Rb self-dose does not significantly affect the dose reading.

2009-01-15

111

Measurement of spatial dose distribution with thermoluminescence sheet around high dose-rate intracavitary sup 60 Co sources  

Energy Technology Data Exchange (ETDEWEB)

A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL sheet was suggested to provide a convenient means of measuring the dose distribution around {sup 60}Co sources in intracavitary ...

1991-06-01

112

Mean glandular doses for women undergoing mammographic breast screening in Oyo state, Nigeria  

British Library Electronic Table of Contents (United Kingdom)

In this work, thermoluminescent dosimeters have been used to measure entrance surface doses (ESDs) of patients undergoing mammographic screening at the University College Hospital, Ibadan, Oyo state. The mean glandular doses (MGDs) were also calculated using the measured ESDs. The results showed that the ESDs ranged from 0.26mGy to 21.26mGy for the mediolateral oblique (MLO) views and 0.08mGy to 5.36mGy for the craniocaudal (CC) views. The calculated MGD ranged from 0.07mGy to 3.57mGy for the MLO views and 0.02mGy to 0.98mGy for the CC views. The possible reasons for the large variations in the individual ESD values and MGD values for both views are discussed using patients data, equipment specific data and the technical parameters used for the examinations. Comparison showed that the mean...

2009-01-01

113

Experimental determination of the dosimetric characteristics for the I-Plant"T"M model 3600 "1"2"5I brachytherapy source  

International Nuclear Information System (INIS)

The dosimetric characteristics for a new brachytherapy seed source (I-Plant"T"M model 3600) were measured using LiF thermoluminescent dosimeters and appropriate phantom materials in conformance with the methodology and guidance provided by the AAPM Task Group 43. The I-Plant"T"M model 3600 is the successor to the I-Plant"T"M model 3500. The major difference between these sources is that the model 3600 contains a leaded-glass core to provide radio-opacity (while the model 3500 contains a silver core), which does not produce spectral contamination upon neutron activation. The dose rate constant #LAMBDA# for the model 3600 was determined to be 1.00 Gy h"-"1 U"-"1 (with a 6% overall relative standard deviation), compared to 1.01 cGy h"-"1 U"-"1 reported for the model 3500 in previous studies. The remaining dosimetric characteristics also are similar for both sources.

2005-06-01

114

X-dosimetry of Tl(InS_2)_1_-_x(FeSe_2)_x single crystals  

International Nuclear Information System (INIS)

Tl(InS_2)_1_-_x(FeSe_2)_x single crystals (where x=0; 0.001; 0.005; 0.01 and 0.015) were grown by the Bridgman-Stockbarger method. Obtained single crystals were crystallized in monoclinic structure. The present paper deals with experimental results relative to X-ray dosimetric characteristics of the Tl(InS_2)_1_-_x(FeSe_2)_x solid solutions at 300 K. Installation URS-55a was the source of radiation. X-ray radiation dose (E) falling on the crystals is measured by the crystalline X-ray dosimeter DRGZ-02. The value of X-ray conductivity coefficient K_#sigma# characterising X-ray sensitivity is defined as K_#sigma#= (#sigma#_E-#sigma#_0)/E#sigma#_0. where #sigma#_E is conductivity under the effect of X-ray radiation by intensity E, #sigma#_0 is conductivity in the lack of radiation. Comparing X-ray dosimetric characteristics of TlInS_2 and Tl(InS_2)_1_-_x(FeSe_2)_x crystals notes that because of partial substitution of [InS_2]- anion radical by [FeSe_2] there have been ...

2003-09-15

115

Xebra electric vehicle. Case study, ZAP - USA; Lithium-ion battery  

Energy Technology Data Exchange (ETDEWEB)

The Zap Xebra Electric Truck is fitted with 23 Li-Ion Cells from China providing a nominal voltage of 72V and a nominal capacity of 400AH. The Li-Ion cells weighing 13 kg each, making the total weight of the battery pack approx. 300 kg. A Battery Management System (BMS) from Lithium Balance is installed to ensure safe, reliable and maximum performance of the batteries. The testing of the Zap Xebra Electric Truck included two kinds of test, a Stop-and-Go test and a range test. Our Stop-and-Go test consists of accelerating the vehicle for 1 km (0.62mi), braking and then accelerate for 1 km(0.62mi), counting the number of stop-and-goes. Our range test is a real-world test including stops, accelerations, driving in the city and in the countryside, going uphill and downhill. This test shows the average range that the end user will experience. Looking at the results of both the tests and comparing them with the data of a Xebra with Pb-acid batteries, we can conclude that ZAP now has a ...

2008-07-01

116

Wilsonville Advanced Coal Liquefaction Research and Development Facility, Wilsonville, Alabama. Development of VaSTeC autoclave technique and application to pilot plant guidance  

Science.gov (United States)

A precise technique for studying coal liquefaction in a 200 cc stirred-batch-autoclave has been developed. Reaction pressures of up to 4000 psig and temperatures of up to 850/sup 0/F can be employed. The slurry temperature in the autoclave is controlled within 2/sup 0/F by raising or lowering the autoclave which is partially submerged in a sandbath; hence the name: Variable Submergence Temperature Control (VaSTeC). Heatup and cooldown are achieved in 5 and 2 minutes, respectively. A mini-scale vacuum distillation procedure was developed for measurement of 1000/sup 0/F-distillate with a repeatability of 0.3%. About 99% material balance is routinely obtained in the autoclave runs. The following yield repeatabilities have been demonstrated (MAF coal basis):H/sub 2/ cons. (0.1%), C/sub 1/ to C/sub 3/ gas (0.3%), C/sub 4/-1000/sup 0/F distillate (2.4%), and unconverted carbon (0.5%). The autoclave can simulate the yield slate of the thermal liquefaction unit (TLU) of ...

1986-04-01

117

Renewable energy technology for off-grid power generation solar hybrid system  

International Nuclear Information System (INIS)

Off-grid power generation is meant to supply remote or rural area, where grid connection is almost impossible in terms of cost and geography, such as island, aborigine's villages, and areas where nature preservation is concern. Harnessing an abundance renewable energy sources using versatile hybrid power systems can offer the best, least-cost alternative solution for extending modern energy services to remote and isolated communities. The conventional method for off-grid power generation is using diesel generator with a renewable energy (RE) technology utilizing solar photovoltaic, wind, biomass, biogas and/or mini/micro hydro. A hybrid technology is a combination of multiple source of energy; such as RE and diesel generator and may also include energy storage such as battery. In our design, the concept of solar hybrid system is a combination of solar with diesel genset and battery as an energy storage. The main objective of the system are to reduce the cost of ...

2006-12-01

118

Hybrid Simulations of Mini Magnetospheres in the Laboratory  

Science.gov (United States)

We use a massively parallel 3D hybrid particle code, dHybrid, to simulate the deflection of plasma beams by a dipole like magnetic field in a laboratory environment. Dipole magnetic fields, along with a plasma injection source to inflate the magnetic field, are now being studied as means of deflecting solar wind and Energetic Particles away from spacecrafts [1,2,3]. We have considered three setups, consistent with the experiments, with a plasma beam fired at i) a dipole field with no plasma injection, ii) a plasma injection source with no dipole field and iii) a dipole field with a plasma injection source. The hybrid simulations help understand the relevant physical phenomena, and enable extrapolation to space plasma scenarios, where setups are similar but plasma parameters differ significantly. The simulation results consistently show the plasma beam being deflected by the dipole field, in the first scenario, with the deflecting distance determined by the magnetic field intensities. ...

2007-11-01

119

Evaluation of the Performance of the Automated NucliSENS easyMAG and EasyQ Systems versus the Roche AmpliPrep-AMPLICOR Combination for High-Throughput Monitoring of Human Immunodeficiency Virus Load?  

Science.gov (United States)

This study presents the data of an evaluation of the automated Nuclisens easyMAG and EasyQ systems versus the Roche AmpliPrep-AMPLICOR combination for testing of high-volume human immunodeficiency virus (HIV) load. This represents a follow-up of a previous study investigating the performance of the real-time Nuclisens assay using the semiautomated NucliSENS miniMAG extraction procedure. Three hundred eighteen patient samples were analyzed using both methods. The easyMAG-EasyQ HIV type 1 system has a higher sensitivity and broader dynamic range than the Cobas AmpliPrep-AMPLICOR system when the standard Roche assay is used alone, 25 to 3,000,000 IU/ml versus 400 to 750,000 HIV RNA copies/ml, respectively. There was significant correlation between the assays (0.93; P < 0.0001), with good accuracy (percent similarity mean ? = 96%), good precision (percent similarity standard deviation = 4.97%), and overall good agreement with a low percent similarity coefficient of ...

2007-05-01

120

Effective didactic skills training for teachers in continuing medical education  

International Nuclear Information System (INIS)

Purpose: To develop, test, evaluate and implement effective state-of-the-art teacher training in didactic skills and methods. The training concept should be designed and beneficial for medical teachers' postgraduate medical education (CME). Materials and methods: A 5-day workshop with 12 theoretical and 9 'hands-on' modules was designed and stepwise improved, according to the trainees' feedback. All trainees were trained in small groups (6 to 10 participants per workshop). The workshops consisted of mini-lectures, repeated micro teaching exercises and video-supported feedback concerning the following key-competencies: Communication of goals; methods to trigger interactivity; design of slides in power point presentations; effective feedback-techniques; and use of media, time-management, skills teaching, assessment methods (e.g. OSCE and others), evaluation and general presentation skills. The evaluation was based on two components: (A) trainees' scores in two ...

2005-09-01

 
 
 
 
121

Adaptation of the low-cost and low-power tactical split Stirling cryogenic cooler for aerospace applications  

Science.gov (United States)

Cryogenic coolers are often used in modern spacecraft in conjunction with sensitive electronics and sensors of military, commercial and scientific instrumentation. The typical space requirements are: power efficiency, low vibration export, proven reliability, ability to survive launch vibration/shock and long-term exposure to space radiation. A long-standing paradigm of exclusively using "space heritage" equipment has become the standard practice for delivering high reliability components. Unfortunately, this conservative "space heritage" practice can result in using outdated, oversized, overweight and overpriced cryogenic coolers and is becoming increasingly unacceptable for space agencies now operating within tough monetary and time constraints. The recent trend in developing mini and micro satellites for relatively inexpensive missions has prompted attempts to adapt leading-edge tactical cryogenic coolers for suitability in the space environment. The primary ...

2011-05-01

122

ARDEC transition armature study. Progress report No. 3, October 1--November 30, 1991  

Energy Technology Data Exchange (ETDEWEB)

This third report covers the period October 1 to November 30, 1991. During this period the authors: (1) fabricated a test fixture for studying hybrid armature brush behavior, (2) reactivated a 140kJ, 1MA capacitor bank, (3) reactivated 25 channels digital data acquisition and reduction system and (4) concluded the use of a DNA funded railgun would serve as the most expedient means to acquire a railgun test bed. Fabrication of a plasma brush test fixture for studying the formation, evolution and stability of plasma brushes was completed. The fixture will serve to study plasma brush parameters, such as brush length and voltage drop, as a function of initial solid foil mass, gap size and current concentration. A 4OkV, 168{mu}f, 140kJ capacitor bank capable of providing more than 1MA of current was reactivated. (The LLNL bank had been developed for opening switch research which was successfully completed.) The bank will be used to power the test fixture with 10{mu}s, flat top current ...

1992-05-13

123

A concept for an advanced computer-based building envelope design tool  

Energy Technology Data Exchange (ETDEWEB)

A review of current daylighting design tools indicates that over 30 tools are now available, including nomographs, protractors, overlays, and programs for micro-, mini-, and mainframe computers. Computer-based tools allow testing and analyzing of more design alternatives under a wider variety of conditions than was previously practical with slower techniques, but they have not fundamentally changed the information available to the design professional. These tools are applicable to certain limited functions of the design process and do not address the varying information needs of the designer at various points in the design process. We describe a concept for a computer-based building envelope design tool that is structured to overcome many of the limitations of the existing tools. The tool would address daylighting design in the context of the overall building envelope design, covering a range of environmental quality issues in addition to quantitative aspects of ...

1986-11-01

124

The main activities and scientific collaboration possibilities at Ankara Nuclear research and training center  

International Nuclear Information System (INIS)

Full text: Founded in 1964, Ankara Nuclear Research and Training Center (ANRTC) conducts and facilitates the scientific activities including training (summer practice, MSc and Ph D studies in physics and chemistry, IAEA fellowship programs etc.), research and other studies in nuclear and related fields. As it's a part of main duties, ANRTC has analysis on the variety of samples, and radiation protection services commercially, for radiation workers in state, public and private sectors. Research, development and application projects implemented in this Center have mostly been supported by State Planning Organization (SPO) and Turkish Atomic Energy Authority (TAEA). In addition to the projects there are on going collaborative studies with some national Universities and International Atomic Energy Agency. The main activities carried out in ANRTC can be summarized as: studies on experimental nuclear physics, application of nuclear techniques such as XRF, XRD, Gamma, Alpha, etc. for ...

2004-10-01

125

The effect of patient shield position on gonad dose during lumbar spine radiography  

Energy Technology Data Exchange (ETDEWEB)

Background: In an effort to standardise radiological practices in the Republic of Ireland, current legislation states that 'written protocols for every type of standard radiological practice shall be established'. In order to fulfil this requirement the Irish Medical Council recommends the protocols issued by the Commission of European Communitees (CEC) for adoption in the country. Whilst this document does provide good guidance with regard to various radiographic factors, patient shielding instructions are notably ambiguous. The aim of this study was to remove some of this ambiguity by defining the optimal method of positioning patient shielding in antero-posterior (AP) and lateral lumbar spine radiographic examinations. These projections were chosen on the basis of their area of coverage being in close to and in some cases including the reproductive organs. They also represent the highest source of collective population dose of any conventional radiographic ...

2010-05-15

126

The effect of patient shield position on gonad dose during lumbar spine radiography  

International Nuclear Information System (INIS)

Background: In an effort to standardise radiological practices in the Republic of Ireland, current legislation states that 'written protocols for every type of standard radiological practice shall be established'. In order to fulfil this requirement the Irish Medical Council recommends the protocols issued by the Commission of European Communitees (CEC) for adoption in the country. Whilst this document does provide good guidance with regard to various radiographic factors, patient shielding instructions are notably ambiguous. The aim of this study was to remove some of this ambiguity by defining the optimal method of positioning patient shielding in antero-posterior (AP) and lateral lumbar spine radiographic examinations. These projections were chosen on the basis of their area of coverage being in close to and in some cases including the reproductive organs. They also represent the highest source of collective population dose of any conventional radiographic examination carried out in ...

2010-05-01

127

Stochastic risk estimation from medical x-ray diagnostic examinations, 2  

International Nuclear Information System (INIS)

The risks of genetic, leukemia and malignant diseases from medical X-ray diagnostic examinations were estimated using the frequency of radiographic and fluoroscopic exposures per diagnostic examination, child expectancy, leukemia and malignancy significant factors, and using a weighting factor determined on the basis of data concerning the cancer mortality among atomic bomb survivors in Nagasaki and of a recommendation of International Commission of Radiological Protection. The organ or tissue doses with respect to the stochastic risks were determined with ionization chambers and thermoluminescent dosimeters placed at the positions of the organs or tissues in a RANDO woman phantom which was exposed to diagnostic X-rays according to technical factors of typical radiographic and fluoroscopic examinations obtained from a nationwide survey. The resultant risks by age-group and type of radiographic and fluoroscopic examination are tabulated in terms of risk level of ...

1981-01-01

128

Semi-empirical simulation of thermoluminescent response under different filter geometries; Simulacao semi-empirica da resposta termoluminescente sob diferentes geometrias de filtro  

Energy Technology Data Exchange (ETDEWEB)

Many thermoluminescent materials has been developed and used for photon personal dosimetry but no one has all desired characteristics alone. These characteristics include robustness, high sensitivity, energy photon independence, large range of photon energy detection, good reproducibility, small fading and simple glow curve with peaks above 150 deg C. Calcium Sulfate Dysprosium doped (CaSO{sub 4}:Dy) phosphor Thermoluminescent Dosimeter (TLD) has been used by many laboratories, mainly in Brazil and India. Another interesting phosphor is Calcium Fluoride (CaF{sub 2}). These phosphor advantages begin to be more required and its disadvantages have became more apparent, in a global market more and more competitive. These phosphors are used in environmental and area monitoring, once they present more sensibility than other phosphors, like LiF:Mg. Theirs mainly disadvantage is a strong energetic dependence response, which must be corrected for theirs application in the ...

2006-07-01

129

Results of a cross-sectional study on the association of electromagnetic fields emitted from mobile phone base stations and health complaints; Ergebnisse einer Querschnittsstudie zum Zusammenhang von elektromagnetischen Feldern von Mobilfunksendeanlagen und unspezifischen gesundheitlichen Beschwerden  

Energy Technology Data Exchange (ETDEWEB)

Background: Despite the fact that adverse health effects are not confirmed for exposure to radiofrequency electromagnetic field (RFEMF) levels below the limit values, as defined in the guidelines of the International Commission on Non-Ionizing Radiation Protection, many persons are worried about possible adverse health effects caused by the RF-EMF emitted from mobile phone base stations, or they attribute their unspecific health complaints like headache or sleep disturbances to these fields. Method: In the framework of a cross-sectional study a questionnaire was sent to 4150 persons living in predominantly urban areas. Participants were asked whether base stations affected their health. Health complaints were measured with standardized health questionnaires for sleep disturbances, headache, health complaints and mental and physical health. 3,526 persons responded (85%) to the questionnaire and 1,808 (51%) agreed to dosimetric measurements in their flats. Exposure was measured in 1,500 ...

2010-07-01

130

Mean glandular doses for women undergoing mammographic breast screening in Oyo state, Nigeria  

Energy Technology Data Exchange (ETDEWEB)

In this work, thermoluminescent dosimeters have been used to measure entrance surface doses (ESDs) of patients undergoing mammographic screening at the University College Hospital, Ibadan, Oyo state. The mean glandular doses (MGDs) were also calculated using the measured ESDs. The results showed that the ESDs ranged from 0.26 mGy to 21.26 mGy for the mediolateral oblique (MLO) views and 0.08 mGy to 5.36 mGy for the craniocaudal (CC) views. The calculated MGD ranged from 0.07 mGy to 3.57 mGy for the MLO views and 0.02 mGy to 0.98 mGy for the CC views. The possible reasons for the large variations in the individual ESD values and MGD values for both views are discussed using patients' data, equipment specific data and the technical parameters used for the examinations. Comparison showed that the mean ESD values and MGD values reported in this work are below published values. The mean of the calculated MGD values is also found to be lower than the recommended ...

2009-11-15

131

Mean glandular doses for women undergoing mammographic breast screening in Oyo state, Nigeria  

International Nuclear Information System (INIS)

In this work, thermoluminescent dosimeters have been used to measure entrance surface doses (ESDs) of patients undergoing mammographic screening at the University College Hospital, Ibadan, Oyo state. The mean glandular doses (MGDs) were also calculated using the measured ESDs. The results showed that the ESDs ranged from 0.26 mGy to 21.26 mGy for the mediolateral oblique (MLO) views and 0.08 mGy to 5.36 mGy for the craniocaudal (CC) views. The calculated MGD ranged from 0.07 mGy to 3.57 mGy for the MLO views and 0.02 mGy to 0.98 mGy for the CC views. The possible reasons for the large variations in the individual ESD values and MGD values for both views are discussed using patients' data, equipment specific data and the technical parameters used for the examinations. Comparison showed that the mean ESD values and MGD values reported in this work are below published values. The mean of the calculated MGD values is also found to be lower than the recommended guidance ...

2009-11-01

132

Dose verification using a pelvic phantom in high dose rate (HDR) brachytherapy  

Energy Technology Data Exchange (ETDEWEB)

High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom. In this study, the humanoid phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the humanoid phantom were then compared with the treatment planning system for the dose verification. The humanoid phantom needs to be designed such that the dose distributions can be quantitatively evaluated thermoluminescent dosimeter (TLD) chips with a dimension of 1/8 and film dosimetry with a spatial resolution of <1 mm used to measure the radiation dosages in the phantom. ...

2003-07-01

133

Development of an irradiation system for a small size continuous run multipurpose gamma irradiator  

International Nuclear Information System (INIS)

The Radiation Technology Center from IPEN-CNEN/SP, Brazil, developed a revolutionary design and national technology, a small-sized continuous run and multipurpose industrial gamma irradiator, to be used as a demonstration facility for manufacturers and contract service companies, which need economical and logistical in-house irradiation system alternatives. Also, to be useful for supporting the local scientific community on development of products and process using gamma radiation, assisting the traditional and potential users on process validation, training and qualification of operators and radioprotection officers. The developed technology for this facility consists of a continuous tote box transport system, comprising a single concrete vault, where the automated transport system of products inside and outside of the irradiator utilizes a rotating door, integrated with the shielding, avoiding the traditional maze configuration. Covering 76 m"2 of floor area, the irradiator design is ...

134

A study of neutron room scattering at RPCF  

International Nuclear Information System (INIS)

High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers dosimeters use CR39 for neutron detection, which are sent to an outside vendor for ...

1997-01-05

135

A study of neutron room scattering at RPCF  

Energy Technology Data Exchange (ETDEWEB)

High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers dosimeters use CR39 for neutron detection, which are sent to an outside vendor for ...

1996-09-01

136

The operating experience for Wolsung Unit 3 commissioning  

International Nuclear Information System (INIS)

This is a slide-based oral presentation given to the COG/IAEA: Fifth technical committee meeting on 'Exchange of operating experience of pressurized heavy water reactors' held in Mangalia, Romania on 7-10 September 1998. Since energization of Wolsung Unit 3 station service transformer on July 12, 1996 a line of initial test program was conducted as follows: 1. ILRT/SIT; 2. Pre-operational and Hot Functional testing with a Light Water and without Fuel in Systems; 3. Load D_2O in Moderator System; 4. Initial fuel loading; 5. Load D_2O in PHT System; 6. Hot Functional Testing with Heavy Water and Fuel in Systems; 7. Criticality and Low Power Physics Testing; 8. Power Ascension Test and, then finally, phase-D test; the plant acceptance test was accomplished after having a Mini-Overhaul to prepare for Commercial Operation. These documents contain not only both overall introduction of commissioning and the first TBN rolling and Synchronization test performed in Hot ...

1998-09-07

137

Application of combined TLD and CR-39 PNTD method for measurement of total dose and dose equivalent on ISS  

Energy Technology Data Exchange (ETDEWEB)

To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca{sub 2}SO{sub 4}:Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let spectrum, dose, and dose equivalent from charged particles of LET{sub {infinity}}H{sub 2}O {>=} 10 ...

2006-07-01

138

Sustainable water resources management in Pakistan  

International Nuclear Information System (INIS)

Total river discharge in Pakistan in summer season vary from 3 thousand to 34 thousand cusses (100 thousand Cusses to 1,200 thousand Cusses) and can cause tremendous loss to human lives, crops and property, this causes the loss of most of the flood water in the lower Indus plains to the sea. Due to limited capacity of storage at Tarbela and Mangla Dams on river Indus and Jhelum, with virtually no control on Chenab, Ravi and Sutlej, devastating problems are faced between July and October in the event of excessive rainfall in the catchments. Due to enormous amounts of sediments brought in by the feeding rivers, the three major reservoirs -Tarbela, Mangla and Chashma will lose their storage capacity, by 25 % by the end of the year 2010, which will further aggravate the water-availability situation in Pakistan. The quality of water is also deteriorating due to urbanization and industrialization and agricultural developments. On the Environmental Front the main problems are water-logging ...

2004-06-07

139

Implementation of an algorithm for absorbed dose calculation in high energy photon beams at off axis points  

International Nuclear Information System (INIS)

Full text: A semiempirical algorithm for absorbed dose calculation at off-axis points in irregular beams was implemented. It is well known that semiempirical methods are very useful because of their easy implementation and its helpfulness in dose calculation in the clinic. These methods can be used as independent tools for dosimetric calculation in many applications of quality assurance. However, the applicability of such methods has some limitations, even in homogeneous media, specially at off axis points, near beam fringes or outside the beam. Only methods derived from tissue-air-ratio (TAR) or scatter-maximum-ratio (SMR) have been devised for those situations, many years ago. Despite there have been improvements for these manual methods, like the Sc-Sp ones, no attempt has been made to extend their usage at off axis points. In this work, a semiempirical formalism was introduced, based on the works of Venselaar et al. (1999) and Sanz et al. (2004), aimed to the Sc-Sp separation. This ...

2008-10-19

140

An Insoluble Titanium-Lead Anode for Sulfate Electrolytes  

Energy Technology Data Exchange (ETDEWEB)

The project is devoted to the development of novel insoluble anodes for copper electrowinning and electrolytic manganese dioxide (EMD) production. The anodes are made of titanium-lead composite material produced by techniques of powder metallurgy, compaction of titanium powder, sintering and subsequent lead infiltration. The titanium-lead anode combines beneficial electrochemical behavior of a lead anode with high mechanical properties and corrosion resistance of a titanium anode. In the titanium-lead anode, the titanium stabilizes the lead, preventing it from spalling, and the lead sheathes the titanium, protecting it from passivation. Interconnections between manufacturing process, structure, composition and properties of the titanium-lead composite material were investigated. The material containing 20-30 vol.% of lead had optimal combination of mechanical and electrochemical properties. Optimal process parameters to manufacture the anodes were identified. Prototypes having ...

2005-05-11

 
 
 
 
141

X-ray dosimetry of TlGaSe_2 single crystals  

International Nuclear Information System (INIS)

TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. X-ray conductivity coefficients K_#sigma# characterising X-ray sensitivity of investigated crystals are determined as the relative ...

142

Retrospective individual dosimetry using luminescence and EPR after radiation accidents  

International Nuclear Information System (INIS)

In areas where radiation dose monitoring has not been performed, it is essential to use material available in the environment be able to rapidly assess doses to individuals for immediate emergency medical care or for general estimation of the radiological consequences. It was shown that certain types of telephone cards containing microchips have the potential to be used as individual radiation dosimeters in emergency situations to detect doses over 250 mGy by luminescence measurements. In order to understand the dosimetric properties of chip cards, the components obtained from INFINIEON Company at various stages of production were used for luminescence measurements. It is found that the protecting layer used above the chips so called 'globe top' is the main source of radiation induced signal in chip cards. The globe top produced by INFINIEON at that stage is found to contain SiO2 and Epoxy. In order to improve the dosimetric properties of the chip cards, the raw ...