WorldWideScience
1

Complex Spatio-Spectral Structure of Diffuse X-Ray emission in the ...  

Science.gov (United States)

SN 1987A: Soft X-Ray Intensity Ratio. 2002-12 to 2000-12. 2005-7 to 2002-12. Contours: 2002-12. (0.5 2 keV). (0.5 2 keV). Contours: 2005-7 ...

2

X-ray magnetic circular dichroism measurements using an X-ray phase retarder on the BM25 A-SpLine beamline at the ESRF  

UK PubMed Central (United Kingdom)

Circularly polarized X-rays produced by a diamond X-ray phase retarder of thickness 0.5 mm in the Laue transmission configuration have been used for recording X-ray magnetic circular dichroism...Full Text Available

2010-05-01

3

Deposition of Cu film on SiO_2 using a partially ionized beam  

International Nuclear Information System (INIS)

Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO_2 substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio I(111)/I(200) reaches its maximum value indicating a strong left-angle 111 right-angle texture, while the impurity concentration and resisitivity are minimum. The correlation ...

1990-01-01

4

Deposition of Cu film on SiO sub 2 using a partially ionized beam  

Energy Technology Data Exchange (ETDEWEB)

Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO{sub 2} substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio {ital I}(111)/{ital I}(200) reaches its maximum value indicating a strong {l angle}111{r angle} texture, while the impurity concentration and resisitivity are minimum. ...

1990-05-01

5

Deposition of Cu film on SiO sub 2 using a partially ionized beam  

Science.gov (United States)

Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO{sub 2} substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio {ital I}(111)/{ital I}(200) reaches its maximum value indicating a strong {l angle}111{r angle} texture, while the impurity concentration and resisitivity are minimum. ...

1990-05-01

6

An Apparent Hard X-ray Decline of CH Cygni  

CERN Document Server

CH Cygni is a symbiotic star consisting of an M giant and an accreting white dwarf, which is known to be a highly variable X-ray source with a complex, two-component, spectra. Here we report on two Suzaku observations of CH Cyg, taken in 2006 January and May, during which the system was seen to be in a soft X-ray bright, hard X-ray faint state. Based on the extraordinary strength of the 6.4 keV fluorescent Fe K-alpha line, we show that the hard X-rays observed with Suzaku are dominated by scattering.

2006-01-01

7

The investigations on K and L X-ray fluorescence parameters of gold compounds  

British Library Electronic Table of Contents (United Kingdom)

The study aimed to determine the chemical effects on the K and L X-ray intensity ratios and the K and L X-ray production cross sections for gold compounds. The K shell fluorescence yields and L shell average yields were also investigated. The samples were excited by 59.5keV ?-rays from an 241Am annular radioactive source and 123.6keV ?-rays from a 57Co annular radioactive source. K and L X-rays emitted from samples were counted by an Ultra-LEGe detector with a resolution of 0.150keV at 5.9keV. The experimental values were compared with theoretical, the semi-empirical and other experimental values.

2010-01-01

8

Quantitative phase imaging using hard x-rays  

International Nuclear Information System (INIS)

The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.

2009-02-01

9

Energetic electrons in impulsive and extended solar flares as deduced from flux correlations between hard X-rays and microwaves  

Energy Technology Data Exchange (ETDEWEB)

The peak flux relationship between hard X-rays and microwaves from solar flares is studied using about 400 events simultaneously recorded with the hard X-ray burst spectrometer on the SMM satellite and the Nobeyama 17 GHz radiometer. The data indicate that the hard X-ray and microwave peak fluxes correlate best for X-ray energies of less than about 80 keV for impulsive flares and greater than about 360 keV for extended flares. By postulating that electrons responsible for microwave emission at 17 GHz are those emitting hard X-rays at these photon energies, it is concluded that: (1) in impulsive flares, microwaves at about 20 GHz are emitted mainly by electrons of less than about 200 keV from a layer through which the electrons stream down into the thick-target hard X-ray source; and (2) in extended ...

1988-01-01

10

Broad-band hard X-ray reflectors  

DEFF Research Database (Denmark)

Interest in optics for hard X-ray broad-band application is growing. In this paper, we compare the hard X-ray (20-100 keV) reflectivity obtained with an energy-dispersive reflectometer, of a standard commercial gold thin-film with that of a 600 bilayer W/Si X-ray supermirror. The reflectivity of the multilayer is found to agree extraordinarily well with theory (assuming an interface roughness of 4.5 Angstrom), while the agreement for the gold film is less, The overall performance of the supermirror is superior to that of gold, extending the band of reflection at least a factor of 2.8 beyond that of the gold, Various other design options are discussed, and we conclude that continued interest in the X-ray supermirror for broad-band hard X-ray applications is warranted.

1997-01-01

11

Investigation on corrosion resistance of amorphous films prepared by ion beam mixing  

International Nuclear Information System (INIS)

Fe-Cr amorphous films have been formed by both in situ evaporation of multilayered films and ion beam mixing in a target chamber of a 200 keV implanter. The effects of Cr content and ion irradiation on the amorphization of films were examined by transmission electron microscope (TEM). Corrosion of film was investigated by means of a potential dynamic polarization. Corrosion resistance of amorphous film in 0.5 mol H-2SO-4 solution is considerably increased than that of pure iron. Using X ray photoelectron spectroscopy (XPS) corrosion resistance in atmosphere of amorphous Fe-Cr passive films formed by P"+ mixing was studied. Results show that the richness of Cr and P exist at the surface of Fe-Cr film.

1991-01-01

12

Evaluation of adhesive plasters by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

A radiometric method was elaborated for surface density determinations of the adhesive layer of plasters by radionuclide X-ray fluorescence using the 17.47 keV bremsstrahlung of "1"4"7Pm/Mo. The bremsstrahlung line excites the 8.63 keV characteristic K#alpha# line of Zn contained in the adhesive layer of the plaster as a filling material in the form of ZnO. In homogeneous adhesive layers the Zn content is proportional to surface density. (author).

1976-01-01

13

Measurement of M shell X-ray production cross sections and fluorescence yields for the elements in the atomic range 70#<=#Z#<=#92 at 5.96 keV  

International Nuclear Information System (INIS)

Total M X-ray cross sections for 12 elements in atomic range 70#<=#Z#<=#92 were measured at 5.96 keV Mn K X-ray photon energy. The average M shell fluorescence yields (anti #omega#_M) of these elements have also been observed using the presently measured cross section values and the theoretical M shell photoionisation cross section values. (orig.).

14

Anode length optimization in a modified plasma focus device for optimal x-ray yields  

International Nuclear Information System (INIS)

The effect of anode length and operating gas pressure on the x-ray emission from a nitrogen-filling modified plasma focus device has been investigated. The time-resolved investigation of x ray was carried out by using a five-channel photodiode x-ray spectrometer. The maximum x-ray yield is seen to increase with the increase in the anode length from 110 to 125 mm. Further increase in the anode length to 130 mm causes the x-ray yields to decrease. The highest x-ray yield of 4.5 J into 4#pi# sr was found for 125 mm anode length, which is 0.2% of the input energy. The average x-ray photon energy was estimated by using half-value thickness method and found to be 8.4 keV. The electron temperature of the plasma was estimated to be around 3 keV by x-ray intensity ...

2006-01-01

15

A Remarkable Low-Mass X-ray Binary within 0.1 pc of the Galactic Center  

CERN Document Server

Recent X-ray and radio observations have identified a transient low-mass X-ray binary (LMXB) located only 0.1 pc in projection from the Galactic center, CXOGC J174540.0-290031. In this paper, we report the detailed analysis of X-ray and infrared observations of the transient and its surroundings. Chandra bservations detect the source at a flux of F_X = 2e-12 erg cm^-2 s^-1 (2-8 keV). After accounting for absorption both in the interstellar medium and in material local to the source, the implied luminosity of the source is only L_X = 4e34 erg/s (2-8 keV; D=8 kpc). However, the diffuse X-ray emission near the source also brightened by a factor of 2. The enhanced diffuse X-ray emission lies on top of a known ridge of dust and ionized gas that is visible infrared images. We interpret the X-ray emission as scattered flux from ...

2005-01-01

16

Chandra Observations of Nuclear X-ray Emission from a Sample of Radio Sources  

CERN Document Server

We present the X-ray properties of a sample of 17 radio sources observed with the Chandra X-ray Observatory as part of a project aimed at studying the X-ray emission from their radio jets. In this paper, we concentrate on the X-ray properties of the unresolved cores. The sample includes 16 quasars (11 core-dominated and 5 lobe-dominated) in the redshift range z=0.30--1.96, and one low-power radio-galaxy at z=0.064. No diffuse X-ray emission is present around the cores of the quasars, except for the nearby low-power galaxy that has diffuse emission on a scale and with a luminosity consistent with other FRIs. No high-amplitude, short-term variability is detected within the relatively short Chandra exposures. However, 1510-089 shows low-amplitude flux changes with a timescale of $\\sim$25 minutes. The X-ray spectra of the quasar cores are generally well described ...

2003-01-01

17

Photon-induced L-shell x-ray intensity ratio for elements with 73 #<=# Z #<=#83 in the energy range 17 #<=# E #<=# 47 keV  

International Nuclear Information System (INIS)

The L-shell x-ray intensity ratios I(L_#beta#)/I(L_#alpha#) and I(L_#gamma#)/I(L_a_l_p_h_a) for elements with 73 #<=# Z #<=# 83 have been measured at photon incident energies of 17.8, 25.8 and 46.9 keV. The emitted x-rays were measured with a Si(Li) detector system. The results for Re, Pt and Tl are being reported for the first time. A comparison is made of the experimental results with the calculated values obtained by using the theoretical x-ray emission rates, subshell ionisation cross sections, subshell fluorescence yields and Coster-Kronig transition probabilities. The experimental results are in reasonable agreement with the theoretical values. (author).

1988-01-01

18

Hard X-ray phase imaging and tomography using a grating interferometer  

International Nuclear Information System (INIS)

An interferometric technique for hard X-rays is presented. It is based on two transmission gratings and a phase-stepping technique, and it provides separate radiographs of the phase and absorption profiles of bulk samples. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index and of the attenuation coefficient, with a spatial resolution down to a few microns. The method is mechanically robust, it requires little monochromaticity, and can be scaled up to large fields of view. These are important prerequisites for use with laboratory X-ray sources. Numerous applications ranging from wave front sensing to medical radiography are presently under investigation.

2007-07-01

19

X-ray dosimetry of TlGaSe_2 single crystals  

International Nuclear Information System (INIS)

TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. ...

20

Observed energy dependence of Fano factor in silicon at hard X-ray energies  

Energy Technology Data Exchange (ETDEWEB)

An experimental evaluation of the Fano factor F in silicon at hard X-ray energies (5.9-136.5 keV) has been performed by means of a low-noise, high charge collection efficiency silicon drift detector with on-chip electronics. A dependence of F from the detector temperature as well as from the energy of the X-ray photons has been found. Assuming a pair creation energy equal to 3.64 eV, at +20 deg. C the F factor was observed to vary from 0.124{+-}0.006 at 5.9 keV up to 0.159{+-}0.002 at 122 keV. At -35 deg. C, the change of F with respect to the photon energy was less remarkable but nevertheless statistically significant, from 0.123{+-}0.002 at 5.9 keV up to 0.134{+-}0.001 at 122 keV. To our knowledge, the present results represent the first experimental evidence of an energy dependence of the Fano factor in silicon at hard ...

1999-03-01

21

Accretion Properties of A Sample of Hard X-ray (<60keV) Selected Seyfert 1 Galaxies  

CERN Document Server

We examine the accretion properties in a sample of 42 hard (3-60keV) X-ray selected nearby broad-line AGNs. The energy range in the sample is harder than that usually used in the similar previous studies. These AGNs are mainly complied from the RXTE All Sky Survey (XSS), and complemented by the released INTEGRAL AGN catalog. The black hole masses, bolometric luminosities of AGN, and Eddington ratios are derived from their optical spectra in terms of the broad H$\\beta$ emission line. The tight correlation between the hard X-ray (3-20keV) and bolometric/line luminosity is well identified in our sample. Also identified is a strong inverse Baldwin relationship of the H$\\beta$ emission line. In addition, all these hard X-ray AGNs are biased toward luminous objects with high Eddington ratio (mostly between 0.01 to 0.1) and low column density ($<10^{22} \\mathrm{cm^{-2}}$), which is ...

2008-01-01

22

X-ray production with sub-picosecond laser pulses  

Energy Technology Data Exchange (ETDEWEB)

The interaction of intense, sub-picosecond laser pulses with solid targets produces intense picosecond x-ray pulses. With focused laser pulses of several 10 {sup 18} W/cm{sup 2}, He-like and H-like line radiation from targets such as aluminum and silicon has been produced. The energy conversion efficiency from the laser pulse energy to the 1--2 keV line x-rays is nearly one percent. The duration of the line x-ray radiation is of the order of ten picoseconds, although this may be an upper estimate because of the temporal resolution of the x-ray streak camera. The spatial extent of the x-ray source region is only slightly larger than the laser focal spot, or about 10 {mu}m in diameter. With these characteristics, such x-ray sources emit an intensity of nearly 10{sup 14} W/cm{sup 2}. Experiments and modeling which led to the above conclusions ...

1993-12-31

23

Hard X-ray identification of Eta Carinae and steadiness close to periastron  

CERN Document Server

Context: The colliding-wind binary Eta Car exhibits soft X-ray thermal emission that varies strongly around periastron, and non-thermal emission seen in hard X-rays and gamma-rays. Aims: To definitively identify Eta Car as the source of the hard X-ray emission, to examine how changes in the 2-10 keV band influence changes in the hard X-ray band, and to understand more clearly the mechanisms producing the non-thermal emission using new INTEGRAL observations obtained close to periastron. Methods: A Chandra observation encompassing the ISGRI error circle was analysed, and all other soft X-ray sources (including the outer shell of Eta Car itself) were discarded as likely counter-parts. New hard X-ray images of Eta Car were studied close to periastron, and compared to previous observations far from periastron. Results: The INTEGRAL component, ...

2010-01-01

24

Z-dependence of photon induced L_#alpha#/L_l X-ray intensity ratio in some elements 73 #<=# Z #<=# 92  

International Nuclear Information System (INIS)

L_#alpha#/L_l X-ray intensity ratios have been measured in elements Ta, W, Au, Hg, Tl, Pb, Bi, Th and U using L-shell photoionization by 60 keV photons. The present results are found to agree with the calculated values of Scofield within experimental uncertainties. (author).

1983-11-21

25

Chemical effects on L_#gamma#_1/L_#beta#_1 x-ray intensity ratio of molybdenum compounds  

International Nuclear Information System (INIS)

Chemical effects on the intensity ratio of LX-ray of molybdenum compounds irradiated by 11-keV electrons and by 3-MeV protons were studied using an x-ray crystal spectrometer. It was found that the intensity ratios of L_#gamma#_1/L_#beta#_1 markedly decrease with the increase of ionicity of molybdenum compounds, except for the case of metallic molybdenum. (author).

1987-06-01

26

Influence of the X-ray radiation on the lifetime of carriers in the p-n junctions of Si and Ge  

International Nuclear Information System (INIS)

Lifetime of minority charae carriers in the Si and Ge p-n unctions has been measured by pulse method of conductivity modulation of base. Its dependence on the X-ray radiation dose has been investigated. Dependence of current transmission coefficients on the dose has been measured and their sharp decrease at low doses and the following saturation at high doses have been observed. Linear dependence of lifetime on X-ray radiation dose has been obtained. Resulting from the comparison of regularities of the change of lifetime due to current characteristics, it has been shown that X-ray radiation leads to the formation of the surface defects, influencing the change of current characteristics as well as to stationary structural defects, causing the decrease of lifetime of the charge carriers with the increase of X-ray radiation dose.

27

Fully Coherent X-ray Pulses from a Regenerative Amplifier Free Electron Laser  

Energy Technology Data Exchange (ETDEWEB)

We propose and analyze a novel regenerative amplifier free electron laser (FEL) to produce fully coherent x-ray pulses. The method makes use of narrow-bandwidth Bragg crystals to form an x-ray feedback loop around a relatively short undulator. Self-amplified spontaneous emission (SASE) from the leading electron bunch in a bunch train is spectrally filtered by the Bragg reflectors and is brought back to the beginning of the undulator to interact repeatedly with subsequent bunches in the bunch train. The FEL interaction with these short bunches not only amplifies the radiation intensity but also broadens its spectrum, allowing for effective transmission of the x-rays outside the crystal bandwidth. The spectral brightness of these x-ray pulses is about two to three orders of magnitude higher than that from a single-pass SASE FEL.

2006-02-17

28

X-ray exposure in the teaching of science at junior and senior high schools  

Energy Technology Data Exchange (ETDEWEB)

A significant amount of X-rays were detected as a leakage from some of the Crooke`s tubes which were used in the teaching of science at junior and senior high schools in Japan. We measured the leaked dose of X-rays from the Crooke`s tubes with ionizing chambers, film badges and TLDs. The maximum leaked dose at 5cm distance from those tubes was estimated 143mSv/h. The effective energy of leaked X-rays was 19.3keV. The maximum dose of students exposed during the teaching of science were estimated 0.15mSv per experiment, which exceeded the value recommended in the ICRP publication 36. (author)

1995-10-01

29

Particle and X-ray damage in pn-CCDs  

Energy Technology Data Exchange (ETDEWEB)

The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.

2000-01-11

30

Total M shell X-ray production cross sections and average fluorescence yields in 11 elements from Tm to U at photon energy of 5.96 keV  

International Nuclear Information System (INIS)

Total M shell X-ray production cross section for 11 elements with 69 #<=# Z #<=# 92 have been measured using an incident photon energy of 5.96 keV. Measurements have been performed using an "5"5Fe annular source and a Si(Li) detector. Average M shell fluorescence yield at each incident photon energy has been deduced, using the experimental total M X-ray production cross section and theoretical M shell photoionization cross section. Present experimental results are compared with other experimental and theoretical values. Reasonable agreement (to within 0.3-28%) is typically obtained between present and other experimental and theoretical values.

2005-04-01

31

The Micro-X Imaging Spectrometer Instrument  

Science.gov (United States)

The Micro-X instrument is a NASA funded, rocket borne X-ray imaging spectrometer planned for launch in January 2011. An array of Transition Edge Sensors (TESs) will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. This will be a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat sink, and will be read out by a SQUID time division multiplexer. X-rays will be focused onto the TES array of 128 pixels on a 600 micron pitch by a conically approximated Wolter optic with an effective area of 200 cm2. The spectrometer will have a field of view of 11.8 arcmin. We describe the design and development progress of the ...

2010-01-01

32

Microstructural observation of focused ion beam modification of Ni silicides/Si thin films  

International Nuclear Information System (INIS)

Focused ion beam (FIB) irradiation of a thin Ni_2Si layer deposited on a Si substrate was carried out and studied using an in-situ transmission electron microscope (in-situ TEM). Square areas on sides of 4 by 4 and 9 by 9 microm were patterned at room temperature with a 25 keV Ga"+-FIB attached to the TEM. The structural changes of the films indicate a uniform milling, sputtering of the Ni_2Si layer and the damage introducing to the Si substrate. Annealing at 673 K results in the change of the Ni_2Si layer into an epitaxial NiSi_2 layer outside the FIB irradiated area, but several precipitates appear around the treated area. Precipitates was analyzed by energy dispersive X-ray spectroscopy (EDS). Larger amount of Ni than the surrounding matrix was found in precipitates. Selected area diffraction (SAD) patterns of the precipitates and the corresponding dark field images imply the formation of a Ni rich silicide. The relation ...

1996-12-02

33

Measurement of K x-ray intensity ratio of tin, gadolinium and dysprosium  

International Nuclear Information System (INIS)

Full text: Measurement of K_#beta# to K_#alpha# x-ray intensity ratios are important not only in the field of atomic physics, radiation physics and medical physics, but also to test the validity of assumptions made in the theoretical prediction. The intensity ratios can also give information on the effect of physical and chemical environment of the element in the compound. Many investigators have adopted a single and double reflection geometries to measure the K_#beta# to K_#alpha# x ray intensity ratios to understand the effect of physical and chemical environment on x-ray fluorescence. The targets are excited by a radioactive source of having activity of the order 100 MBq. in order to carry out accurate measurement K_#beta# to K_#alpha# x-ray intensity ratios, we have develop 2#pi# geometrical configuration method : placing a target right on the surface of the detector facing the ...

2003-11-01

34

RXTE observations of Cas A  

International Nuclear Information System (INIS)

Rossi X-ray Timing Explorer (RXTE) observations of the bright supernova remnant Cas A have revealed a hard power law component above 10 keV in addition to two thermal components inferred from ASCA measurements of the many line centroids from low-Z elements. The power law can be shown to be consistent with synchrotron emission from radio to hard x-rays by electrons of up to 4 x 10"1"3 eV. Measurement of the 1157 keV line by CGRO from "4"4Sc in the chain of decay of "4"4Ti predicts that the two "4"4Ti lines at 68 and 78 keV should appear at the CGRO intensity. RXTE has placed upper limits on such lines that are marginally consistent with the CGRO measurement. Implications of these results on sites for cosmic ray acceleration and nucleosynthesis are discussed.

1999-01-01

35

Resonant inelastic soft x-ray scattering of CdS: a two-dimensional electronic structure map approach  

Energy Technology Data Exchange (ETDEWEB)

Resonant inelastic x-ray scattering (RIXS) with soft x-rays is uniquely suited to study the elec-tronic structure of a variety of materials, but is currently limited by low (fluorescence yield) count rates. This limitation is overcome with a new high-transmission spectrometer that allows to measure soft x-ray RIXS"maps." The S L2,3 RIXS map of CdS is discussed and compared with density functional calculations. The map allows the extraction of decay channel-specific"absorp-tion spectra," giving detailed insight into the wave functions of occupied and unoccupied elec-tronic states.

2008-09-24

36

Evaluation of diagnostic digital radiography of the chest in comparison with conventional chest x-ray films  

International Nuclear Information System (INIS)

Digital radiography for diagnosis of chest diseases using Fuji Computed Radiography (FCR) was evaluated. The results were as follows; 1. Compared to the conventional chest X-ray films, various types of image enhancement could be made by manipulation of the digital information such as tone conversion, spatial frequency modification etc. 2. Digital radiography lessens the X-ray exposure dose and will ultimately permit speedy transmission of image data from outlying clinics to central processing hospitals. 3. Digital radiographic images are useful in chest X-ray diagnosis especially in mass surveys for lung cancer and in primary care medicine because of its full imaging capability. (author).

1983-01-01

37

Measurements of K-shell x-ray production cross sections and K to L and M-shell radiative vacancy transfer probabilities for Nd, Eu, Gd, Dy and Ho at excitation with 59.5 keV photons in an external magnetic field  

International Nuclear Information System (INIS)

The effect of the #+-# 0.75 T external magnetic field on the K_#alpha#_1, K_#alpha#_2, K_#beta#_'_1 and K_#beta#_'_2 x-ray production cross sections and radiative vacancy transfer probabilities from K-shell to L2 and L3 subshells and M-shell for ferromagnetic Nd, Gd and Dy and paramagnetic Eu and Ho have been investigated, using the 59.5 keV incident photons. K-shell fluorescence yields and K x-ray intensity ratios for these elements have been determined in the external magnetic field also. The K x-rays from different targets were detected using a high-resolution Si(Li) semiconductor detector. For B = 0, the present experimental results were compared with the experimental and theoretical data in the literature. The results show that K-shell fluorescence parameters such as photoionization cross section, fluorescence yield, radiation rates, vacancy transfer probabilities and spectral linewidth can change ...

2006-06-19

38

Measurement of relative L X-ray intensity ratio following radioactive decay and photoionization  

International Nuclear Information System (INIS)

The measurements of the L X-ray intensity ratio I(L?)/I(L?), I(L?)/I(L?), I(L?)/I(L?), I(L?)/I(L?) and I(L?)/I(L?) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV ?-rays from a filtered radioisotope 241Am was used, and by the radioactive decay of 160Tb, 160Er, 173Lu, 182Re, 201Tl, 203Pb and 207Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L?/L?), I(L?/L?), I(L?/L?), I(L?/L?) and I(L?/L?) intensity ratios were calculated using theoretically tabulated values of subshell photoionization cross-section, fluorescence yield, fractional X-ray emission rates, Coster-Kronig transition probabilities. It was observed that present values agree with previous theoretical and ...

2008-05-22

39

X-ray, Optical, and Radio Observations of SN 1999em and SN 1998S  

CERN Document Server

Observations of the Type II-P (plateau) Supernova (SN) 1999em and Type IIn (narrow emission line) SN 1998S have enabled estimation of the profile of the SN ejecta, the structure of the circumstellar medium (CSM) established by the pre-SN stellar wind, and the nature of the shock interaction. SN 1999em is the first and only Type II-P detected at both X-ray and radio wavelengths. It is the least radio luminous and one of the least X-ray luminous SN ever detected (except for the unusual and very close SN 1987A). The Chandra X-ray data indicate non-radiative interaction of SN ejecta with a power-law density profile (rho \\propto r^{-n} with n ~ 7) with a pre-SN wind with a low mass loss rate of ~2 \\times 10^{-6} Msun/yr for a wind velocity of 10 km/sec, in close agreement with radio mass-loss rate estimates. The Chandra data show an unexpected, temporary rise in the 0.4--2.0 keV X-ray ...

2001-01-01

40

The intriguing nature of the high energy gamma ray source XSSJ12270-4859  

CERN Document Server

The nature of the hard X-ray source XSSJ12270-4859 is still unclear though it was claimed to be a magnetic Cataclysmic Variable. We here present a broad-band X-ray and gamma ray study based on a recent XMM-Newton observation and archival INTEGRAL and RXTE data. From the Fermi/LAT 1-year point source catalogue, we tentatively associate XSSJ12270-4859 with 1FGLJ1227.9-4852, a source of high energy gamma rays with emission up to 10GeV. We complement the study with UV photometry from XMM-Newton and ground-based optical and near-IR photometry. The X-ray emission is highly variable showing flares and intensity dips. The X-ray flares consist of flare-dip pairs. Flares are also detected in the UV range but not the dips. Aperiodic dipping behaviour is also observed during X-ray quiescence but not in the UV. The 0.2-100keV spectrum is featureless and described by a power ...

2010-01-01

41

Zinc determination in medicinal powders by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

X-ray fluorescence analysis was used to determine the zinc content of the ''Perilacin'' powder and the ZnO content of the ''Epiderman-pix'' powder. The characteristic Ksub(#alpha#) line of zinc was excited using a "1"4"7Pm/Mo source (10"7 s"-"1) and the molybdenum Ksub(#alpha#) line (17.47 keV). 4 to 5% Zn and 45 to 49% ZnO were determined with a NaI(Tl) scintillation detector. The radiation intensity was found to decrease with particle size. (M.K.).

1977-01-01

42

Photon-induced K-shell X-ray intensity ratio for elements with 74#<=#Z#<=#92  

International Nuclear Information System (INIS)

The K-shell X-ray intensity ratios for W, Au, Tl, Pb, Bi, Th and U were measured at a photon incident energy of 121.9 keV from "5"7Co radionuclide. A comparison between the experimental results and the theoretically calculated values shows that the experimental results are, in general, higher than the theoretical values. The measured intensities are regarded to be reported for the first time. (author) 9 refs.; 1 tab.

1989-01-01

43

X-ray Phase Imaging Microscopy using a Fresnel Zone Plate and a Transmission Grating  

International Nuclear Information System (INIS)

We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.

2010-06-23

44

The X-ray Halo of G21.5-0.9  

CERN Document Server

The emission of the plerion G21.5-0.9 appears more extended in X rays than in radio. This is an unexpected result because it would imply that short-lived X-ray electrons may reach distances even larger than radio electrons. Applying an empirical relationship between dust scattering optical depth and photoelectric column density, the measured column density leads to a large optical depth at 1 keV, of about 1. Therefore we investigate the hypothesis that the detected halo be an effect of dust scattering, re-analyzing an Cal/PV XMM-Newton observation of G21.5-0.9 and critically examining it in terms of a dust scattering model. We also present a spectral analysis of a prominent extended feature in the northern sector of the halo.

2003-01-01

45

Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization  

Energy Technology Data Exchange (ETDEWEB)

The measurements of the K X-ray intensity ratio I(K{alpha} {sub 2}/K{alpha} {sub 1}), I(K{beta} {sub 1}/K{alpha} {sub 1}) and I(K{beta}/K{alpha}) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a {sup 241}Am and 123.6 keV {gamma}-rays from a {sup 60}Co were used, and following the radioactive decay of {sup 51}Cr, {sup 55}Fe, {sup 67}Ga, {sup 99}Tc, {sup 111}In, {sup 131}I, {sup 133}Ba, {sup 133}Xe, {sup 137}Cs, {sup 201}Tl and {sup 226}Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.

2007-01-15

46

Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization  

International Nuclear Information System (INIS)

The measurements of the K X-ray intensity ratio I(K#alpha# _2/K#alpha# _1), I(K#beta# _1/K#alpha# _1) and I(K#beta#/K#alpha#) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV #gamma#-rays from a "2"4"1Am and 123.6 keV #gamma#-rays from a "6"0Co were used, and following the radioactive decay of "5"1Cr, "5"5Fe, "6"7Ga, "9"9Tc, "1"1"1In, "1"3"1I, "1"3"3Ba, "1"3"3Xe, "1"3"7Cs, "2"0"1Tl and "2"2"6Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.

2007-01-01

47

X-dosimetry of Tl(InS_2)_1_-_x(FeSe_2)_x single crystals  

International Nuclear Information System (INIS)

Tl(InS_2)_1_-_x(FeSe_2)_x single crystals (where x=0; 0.001; 0.005; 0.01 and 0.015) were grown by the Bridgman-Stockbarger method. Obtained single crystals were crystallized in monoclinic structure. The present paper deals with experimental results relative to X-ray dosimetric characteristics of the Tl(InS_2)_1_-_x(FeSe_2)_x solid solutions at 300 K. Installation URS-55a was the source of radiation. X-ray radiation dose (E) falling on the crystals is measured by the crystalline X-ray dosimeter DRGZ-02. The value of X-ray conductivity coefficient K_#sigma# characterising X-ray sensitivity is defined as K_#sigma#= (#sigma#_E-#sigma#_0)/E#sigma#_0. where #sigma#_E is conductivity under the effect of X-ray radiation by intensity E, #sigma#_0 is conductivity in the lack of radiation. Comparing X-ray dosimetric characteristics of TlInS_2 and ...

2003-09-15

48

Investigation by XRF and XRD of Zn and Fe in Fe{sub x} Zn{sub 1-x} thin films  

Energy Technology Data Exchange (ETDEWEB)

Fe{sub x}Zn{sub 1-x} alloys were electrochemically deposited on aluminum substrates from a sulfate bath. The K{beta}/K{alpha} x-ray intensity ratios of Zn and Fe in Fe{sub x}Zn{sub 1-x} thin films have been experimentally studied. The energy dispersive x-ray fluorescence (EDXRF) technique was used to measure K x-ray photons. Samples were excited by using 59.5 keV photons emitted by a 50 mCi {sup 241}Am radioactive source. The emitted K x-rays were detected by an Ultra-LEGe detector having a resolution of 150 eV at 5.9 keV. In addition, the effect of bath composition on the phase structure was investigated by x-ray diffraction (XRD) analysis. The composition of the thin films was analyzed by atomic absorption spectrometry analysis. Iron content was shown to strongly affect the structure of Zn-Fe alloys. It was found that the K-shell ...

2008-12-15

49

Investigation by XRF and XRD of Zn and Fe in Fex Zn1-x thin films  

International Nuclear Information System (INIS)

FexZn1-x alloys were electrochemically deposited on aluminum substrates from a sulfate bath. The K?/K? x-ray intensity ratios of Zn and Fe in FexZn1-x thin films have been experimentally studied. The energy dispersive x-ray fluorescence (EDXRF) technique was used to measure K x-ray photons. Samples were excited by using 59.5 keV photons emitted by a 50 mCi 241Am radioactive source. The emitted K x-rays were detected by an Ultra-LEGe detector having a resolution of 150 eV at 5.9 keV. In addition, the effect of bath composition on the phase structure was investigated by x-ray diffraction (XRD) analysis. The composition of the thin films was analyzed by atomic absorption spectrometry analysis. Iron content was shown to strongly affect the structure of Zn-Fe alloys. It was found that the K-shell x-ray intensity ratio changed ...

2008-12-01

50

Valence-electron configuration of Ti and Ni in TixNi1-x alloys from Kbeta-to-Kalpha X-ray intensity ratio studies.  

Science.gov (United States)

Kbeta-to-Kalpha X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of Ti(x)Ni(1-x) (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi (109)Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured Kbeta-to-Kalpha X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other element and/or the ...

2010-01-28

51

Valence-electron configuration of Ti and Ni in TixNi1-x alloys from K?-to-K? X-ray intensity ratio studies  

International Nuclear Information System (INIS)

K?-to-K? X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of TixNi1-x (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi 109Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured K?-to-K? X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other element and/or the rearrangement of ...

2010-06-01

52

M X-ray production in Nd, Gd, Ho and Lu by 1-6 MeV lithium ions  

Energy Technology Data Exchange (ETDEWEB)

M-shell X-rays of the rare-earth elements {sub 60}Nd, {sub 64}Gd, {sub 67}Ho and {sub 71}Lu were measured for lithium ion bombardment in the energy range 1.0-6.0 MeV. The M-shell X-rays with energies of 0.978-1.631 keV were detected with a LINK analytical detector. The efficiency of the detector was determined by using the known atomic-field bremsstrahlung cross-sections from low energy electron beams and K-shell X-ray measurements with light projectiles. The measured cross-sections are compared to the predictions of the first Born approximation and the ECPSSR (energy loss and Coulomb deflection effects, perturbed stationary state approximation with relativistic correction) theories. The best theoretical description of the present data is given by the ECPSSR theory, even though the discrepancy between data and theory is increasing at higher projectile energies.

2004-06-01

53

Large area, low capacitance Si(Li) detectors for high rate x-ray applications  

Energy Technology Data Exchange (ETDEWEB)

Large area, single-element Si(Li) detectors have been fabricated using a novel geometry which yields detectors with reduced capacitance and hence reduced noise at short amplifier pulse-processing times. A typical device employing the new geometry with a thickness of 6 mm and an active area of 175 mm 2 has a capacitance of only 0.5 pf, compared to 2.9 pf for a conventional planar device with equivalent dimensions. These new low capacitance detectors, used in conjunction with low capacitance field effect transistors, will result in x-ray spectrometers capable of operating at very high count rates while still maintaining excellent energy resolution. The spectral response of the low capacitance detectors to a wide range of x-ray energies at 80 K is comparable to typical state-of-the-art conventional Si(Li) devices. In addition to their low capacitance, the new devices offer other advantages over conventional detectors. Detector fabrication ...

1992-10-01

54

Grain boundary transport in x-ray irradiated polycrystalline diamond  

International Nuclear Information System (INIS)

The transport properties of a 'thin' polycrystalline diamond film are analyzed after the sample exposure to 8.06-keV x-ray radiation. Structure and morphology of the as-grown film have been evaluated by Raman, x-ray diffraction, and scanning electron microscopy techniques. The transport properties have been investigated by measuring dark current-voltage characteristics in the temperature range of 60 to 360 K. Ohmic transport has been evidenced on the as-grown film up to 1.16x10"5 V/cm. After irradiation, nonlinear contributions to the dark current have been evidenced and related to field-assisted thermal ionization of traps. Below 200 K, hopping mechanisms have been observed. Correlations have been found among x-ray irradiation, density of traps involved in the transport processes, and the nonhomogeneous nature of the sample. A simple model of the grain boundary structure is proposed to explain the ...

2003-05-15

55

Alloying effect on K to L shell vacancy transfer probabilities in 3d transition metals  

British Library Electronic Table of Contents (United Kingdom)

The alloying effects on K to L shell vacancy transfer probabilities (?KL) in 3d transition metals have been carried out by X-ray fluorescence studies of various alloy compositions. K X-ray intensity ratios of Ti, Cr, Fe, Co, Ni, and Cu elements in the FexNi1?x, FexCr1?x, NixCr1?x, FexCryNi1?(x+y), TixNi1?x, TixCo1?x, and CoxCu1?x alloys have been measured following excitation by 22.69keV X-rays from a 10 mCi 109Cd radioactive point source and ?KL values for alloying elements have been determined from these ratios. The spectrum of characteristic K-X-ray photons from samples were detected with a high resolution Si(Li) detector coupled to a 4 K multichannel analyzer. The present investigation makes it possible to ...

2010-01-01

56

A Distinctive Disk-Jet Coupling in the Seyfert-1 AGN NGC 4051  

CERN Document Server

We report on the results of a simultaneous monitoring campaign employing eight Chandra X-ray (0.5-10 keV) and six VLA/EVLA (8.4 GHz) radio observations of NGC 4051 over seven months. Evidence for compact jets is observed in the 8.4 GHz radio band; This builds on mounting evidence that jet production may be prevalent even in radio-quiet Seyferts. Assuming comparatively negligible local diffuse emission in the nucleus, the results also demonstrate an inverse correlation of L_radio proportional to L_X-ray ^(-0.72+/-0.04) . Current research linking the mass of supermassive black holes and stellar-mass black holes in the "low/hard" state to X-ray luminosities and radio luminosities suggest a "fundamental plane of accretion onto black holes" that has a positive correlation of L_radio proportional to L_X-ray^(0.67+/-0.12) . Our simultaneous results differ from this relation by more than 11 ...

2010-01-01

57

An X-ray photoelectron spectroscopic study of B-N-Ti system  

International Nuclear Information System (INIS)

Composite nitrides (such as BN, TiN) are widely used in various industrial applications because of their extreme wear and corrosion resistance, thermal and electrical properties. in order to obtain composite materials with these optimal properties, it is important to elucidate whether any chemical reactions occur at nitride/metal interfaces, e.g., those involving BN-Ti/TiN. Materials of interest include the deposition by PVD of Ti and TiN on BN substrates. Some of these systems were then subjected to varying degrees of physical and thermal alteration. Detailed X-ray photoelectron spectroscopy (XPS) has therefore been rendered of these interfaces using cross-sectional display and sputter etching. Resulting structural and morphological features have been investigated with transmission electron microscopy (TEM) and X-ray diffraction (XRD). Diffusion of the nitridation, oxynitride formation and interfacial growth are of general ...

1997-04-04

58

Suzaku and Optical Spectroscopic Observations of SS 433 in the 2006 April Multiwavelength Campaign  

CERN Document Server

We report results of the 2006 April multi-wavelengths campaign of SS 433, focusing on X-ray data observed with Suzaku at two orbital phases (in- and out-of- eclipse) and simultaneous optical spectroscopic observations. By analyzing the Fe25 K_alpha lines originating from the jets, we detect rapid variability of the Doppler shifts, dz/dt ~ 0.019/0.33 day^-1, which is larger than those expected from the precession and/or nodding motion. This phenomenon probably corresponding to "jitter" motions observed for the first time in X-rays, for which significant variability both in the jet angle and intrinsic speed is required. From the time lag of optical Doppler curves from those of X-rays, we estimate the distance of the optical jets from the base to be ~(3-4) \\times 10^14 cm. Based on the radiatively cooling jet model, we determine the innermost temperature of the jets to be T_0 = 13 +/- 2 keV and 16 +/- 3 ...

2010-01-01

59

Microstructures for high-energy x-ray and particle-imaging applications  

Energy Technology Data Exchange (ETDEWEB)

Coded imaging techniques using thick, micro-Fresnel zone plates as coded apertures have been used to image x-ray emissions (2-20 keV) and 3.5 MeV Alpha particle emissions from laser driven micro-implosions. Image resolution in these experiments was 3-8 ..mu..m. Extension of this coded imaging capability to higher energy x-rays (approx. 100 keV) and more penetrating charged particles (e.g. approx. 15 MeV protons) requires the fabrication of very thick (50-200 ..mu..m), high aspect ratio (10:1), gold Fresnel zone plates with narrow linewidths (5-25 ..mu..m) for use as coded aperatures. A reactive ion etch technique in oxygen has been used to produce thick zone plate patterns in polymer films. The polymer patterns serve as electroplating molds for the subsequent fabrication of the free-standing gold zone plate structures.

1981-05-01

60

Microstructures for high-energy x-ray and particle imaging applications  

Energy Technology Data Exchange (ETDEWEB)

Coded imaging techniques using thick, micro-Fresnel zone plates as coded apertures have been used to image x-ray emission (2--20 keV) and 3.5 MeV Alpha particle emissions from laser driven micro-implosions. Image resolution in these experiments was 3--8 ..mu..m. Extension of this coded imaging capability to higher energy x rays (approx.100 KeV) and more penetrating charged particles (e.g., approx.15 MeV protons) requires the fabrication of very thick (50--200 ..mu..m), high aspect ratio (10:1), gold Fresnel zone plates with narrow linewidths (5--25 ..mu..m) for use as coded apertures. A reactive ion etch technique in oxygen has been used to produce thick zone plate patterns in polymer films. The polymer patterns serve as electroplating molds for the subsequent fabrication of the free-standing gold zone plate structures.

1981-11-01

61

Integration and Testing of the Micro-X Rocket Payload  

Science.gov (United States)

The Micro-X instrument is a rocket borne, X-ray imaging spectrometer planned for launch in October 2011. An array of 128 Transition Edge Sensors (TESs) on a 600 micron pitch will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. X-rays will be focused onto the TES array by a conically approximated Wolter optic with an effective area of 300 cm^2 giving the instrument a field of view of 11.8 arcmin. This performance will constitute a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat bath, and will be read out by a SQUID time division multiplexer. The first flight of the Micro-X instrument will observe the ...

2011-05-01

62

Search for anisotropy in the L x-gamma angular correlations following the decay of "2"0"7Bi  

International Nuclear Information System (INIS)

An investigation of the Ll x-#gamma# angular correlations following the decay of "2"0"7Bi is done by using a Si(Li) semiconductor counter as L x-ray detector. Coincidence measurements at five different angles were made between the 570-keV #gamma# ray (gated in the movable counter) and the Ll x spectrum (displayed in a multichannel analyzer).

63

Energy dependence of Ksub(#beta#)/Ksub(#alpha#) intensity ratio of Si0_2 from proton induced ionisation  

International Nuclear Information System (INIS)

The Ksub(#beta#)/Ksub(#alpha# 12) x-ray intensity ratio of the Si K spectrum was measured for proton impact on Si0_2 in the energy range 300-800 keV. An energy dependence of the intensity ratio was found and an explanation is given in terms of multiple ionisation. (author).

1980-04-01

64

Variability and spectral modeling of the hard X-ray emission of GX 339-4 in a bright low/hard state  

CERN Document Server

We study the high-energy emission of the Galactic black hole candidate GX 339-4 using INTEGRAL/SPI and simultaneous RXTE/PCA data. By the end of January 2007, when it reached its peak luminosity in hard X-rays, the source was in a bright hard state. The SPI data from this period show a good signal to noise ratio, allowing a detailed study of the spectral energy distribution up to several hundred keV. As a main result, we report on the detection of a variable hard spectral feature (>150 keV) which represents a significant excess with respect to the cutoff power law shape of the spectrum. The SPI data suggest that the intensity of this feature is positively correlated with the 25 - 50 keV luminosity of the source and the associated variability time scale is shorter than 7 hours. The simultaneous PCA data, however, show no significant change in the spectral shape, indicating that the source is not ...

2010-01-01

65

An X-ray source population study of the Andromeda galaxy M 31  

CERN Document Server

XMM-Newton EPIC observations reveal the population of X-ray sources of the bright Local Group spiral galaxy M 31, a low-star-formation-rate galaxy like the Milky Way, down to a 0.2-4.5 keV luminosity of 4.4E34 erg/s. With the help of X-ray hardness ratios and optical and radio information different source classes can be distinguished. The survey detected 856 sources in an area of 1.24 square degrees. Sources within M 31 are 44 supernova remnants (SNR) and candidates, 18 super-soft sources (SSS), 16 X-ray binaries (XRBs) and candidates, as well as 37 globular cluster sources (GlC) and candidates, i.e. most likely low mass XRBs within the GlC. 567 hard sources may either be XRBs or Crab-like SNRs in M 31 or background AGN. 22 sources are new SNR candidates in M 31 based on X-ray selection criteria. Time variability information can be used to improve the source classification. Two GlC ...

2005-01-01

66

The search for decaying Dark Matter  

CERN Document Server

We propose an X-ray mission called Xenia to search for decaying superweakly interacting Dark Matter particles (super-WIMP) with a mass in the keV range. The mission and its observation plan are capable of providing a major break through in our understanding of the nature of Dark Matter (DM). It will confirm, or reject, predictions of a number of particle physics models by increasing the sensitivity of the search for decaying DM by about two orders of magnitude through a wide-field imaging X-ray spectrometer in combination with a dedicated observation program. The proposed mission will provide unique limits on the mixing angle and mass of neutral leptons, right handed partners of neutrinos, which are important Dark Matter candidates. The existence of these particles is strongly motivated by observed neutrino flavor oscillations and the problem of baryon asymmetry of the Universe. In super-WIMP models, the details of the ...

2009-01-01

67

Study of the cyclotron feature in MXB 0656-072  

CERN Document Server

We have monitored a Type II outburst of the Be/X-ray binary MXB 0656-072 in a series of pointed RXTE observations during October through December 2003. The source spectrum shows a cyclotron resonance scattering feature at 32.8 +/- 0.5 keV, corresponding to a magnetic field strength of (3.67 +/- 0.06) x 10^12 G and is stable through the outburst and over the pulsar spin phase. The pulsar, with an average pulse period of 160.4 +/- 0.4 s, shows a spin-up of 0.45 s over the duration of the outburst. From optical data, the source distance is estimated to be 3.9 +/- 0.1 kpc and this is used to estimate the X-ray luminosity and a theoretical prediction of the pulsar spin-up during the outburst.

2006-01-01

69

The peak to background method in quantitative ion microprobe analysis of thick biological specimens  

Energy Technology Data Exchange (ETDEWEB)

The use of the ratio of the characteristic intensity to the continuum background intensity (P/B ratio) of the X-ray spectrum for a quantitative ion microprobe (IMP) or PIXE (particle induced X-ray emission) analysis of thin biological specimens was proposed previously. The IMP analysis of thick biological specimens is also of considerable practical use. In this paper, the possibility of using the P/B ratio to quantify minor elements in thick biological specimens is investigated. The epoxy resin based standards with gradual concentrations of KCNS up to 0.6 mol/kg and NBS bovine liver were analyzed by a 27 MeV {alpha} particle microprobe. The measured peak to background ratios (between 4.4 to 5.7 keV) agreed well with the theoretical calculations. The calculations showed that the concentration dependence of the P/B ratios was determined mainly by the absorption of X-rays in specimens. The results indicate ...

1991-05-01

70

Nonformity of the electron density in amorphous silicon films  

Energy Technology Data Exchange (ETDEWEB)

The authors study the nonuniformity of a-Si:H films obtained by the method of vacuum condensation, with the help of x-ray small-angle scattering (SLS) and transmission electron microscopy. Films of hydrogenated amorphous silicon are greatest interest, because the electronic properties of this material can be controlled by doping. As a result of the compensation of the ruptured bonds, and possibly, effects of melting, the properties of such films are analogous to those of singlecrystalline silicon. XLS enables a quantitative determination of the prameters of the regions of low electron density (RLD) in such objects.

1985-12-01

71

Measurement of relative L X-ray intensity ratio following radioactive decay and photoionization  

Energy Technology Data Exchange (ETDEWEB)

The measurements of the L X-ray intensity ratio I(L{alpha})/I(L{beta}), I(L{alpha})/I(L{gamma}), I(L{alpha})/I(L{iota}), I(L{beta})/I(L{gamma}) and I(L{iota})/I(L{gamma}) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a filtered radioisotope {sup 241}Am was used, and by the radioactive decay of {sup 160}Tb, {sup 160}Er, {sup 173}Lu, {sup 182}Re, {sup 201}Tl, {sup 203}Pb and {sup 207}Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L{alpha}/L{beta}), I(L{alpha}/L{gamma}), I(L{alpha}/L{iota}), I(L{beta}/L{gamma}) and I(L{iota}/L{gamma}) intensity ratios were calculated using theoretically tabulated values of subshell photoionization cross-section, fluorescence yield, ...

2008-05-22

72

Comparison of enhanced device response and predicted x-ray dose enhancement effects on MOS oxides  

Energy Technology Data Exchange (ETDEWEB)

The response of MOS capacitors to low- and medium-energy x-ray irradiation is investigated as a function of gate material (TaSi or Al), oxide thickness, and electric field. Measured device response is compared with predictions based on discrete ordinates and Monte Carlo code simulations of dose enhancement effects, coupled with recent estimates of electron-hole recombination in MOS oxides. In comparisons of 10-keV x-ray and Co-60 irradiations of Al-gate MOS capacitors at an oxide electric field of 1 MV/cm, it is found that predictions and experiments agree to within better than 20 percent for oxide thicknesses ranging from 35 to 1060 nm. For capacitors having TaSi/Al gates, predictions and experiments agree to within better than 30 percent at 1 MV/cm, with the largest differences occurring for 35-nm gate oxides. At other electric fields, the disagreement between experiment and prediction increases significantly for both Al- ...

1988-12-01

73

Comparison of enhanced device response and predicted x-ray dose enhancement effects on MOS oxides  

International Nuclear Information System (INIS)

The response of MOS capacitors to low- and medium-energy x-ray irradiation is investigated as a function of gate material (TaSi or Al), oxide thickness, and electric field. Measured device response is compared with predictions based on discrete ordinates and Monte Carlo code simulations of dose enhancement effects, coupled with recent estimates of electron-hole recombination in MOS oxides. In comparisons of 10-keV x-ray and Co-60 irradiations of Al-gate MOS capacitors at an oxide electric field of 1 MV/cm, it is found that predictions and experiments agree to within better than 20 percent for oxide thicknesses ranging from 35 to 1060 nm. For capacitors having TaSi/Al gates, predictions and experiments agree to within better than 30 percent at 1 MV/cm, with the largest differences occurring for 35-nm gate oxides. At other electric fields, the disagreement between experiment and prediction increases significantly for both Al- ...

1988-07-12

74

Study of the crystallographic architecture of corals at the nanoscale by scanning transmission X-ray microscopy and transmission electron microscopy.  

Science.gov (United States)

We have investigated the nanotexture and crystallographic orientation of aragonite in a coral skeleton using synchrotron-based scanning transmission X-ray microscopy (STXM) and transmission electron microscopy (TEM). Polarization-dependent STXM imaging at 40-nm spatial resolution was used to obtain an orientation map of the c-axis of aragonite on a focused ion beam milled ultrathin section of a Porites coral. This imaging showed that one of the basic units of coral skeletons, referred to as the center of calcification (COC), consists of a cluster of 100-nm aragonite globules crystallographically aligned over several micrometers with a fan-like distribution and with the properties of single crystals at the mesoscale. The remainder of the skeleton consists of aragonite single-crystal fibers in crystallographic continuity with the nanoglobules comprising the COC. Our observation provides information on the nm-scale processes ...

2011-05-05

75

Energy Dispersive X-ray Analysis in the Electron Microscope  

CERN Document Server

Energy Dispersive X-ray Analysis in the Electron Microscope

2003-01-01

76

ASE FILE  

Science.gov (United States)

radionuclide X-ray fluorescence analysis: the resolving power of the ... The radiation detectors used in radionuclide X-ray fluorescence ...

77

Measurement of L X-ray fluorescence cross-sections for elements with 45 Z50 using synchrotron radiation at 8keV  

British Library Electronic Table of Contents (United Kingdom)

The L shell fluorescence cross-sections of the elements in range 45Z50 have been determined at 8keV using Synchrotron radiation. The individual L X-ray photons, Ll, La, LbI, LbII, LgI and LgII produced in the target were measured with high resolution Si(Li) detector. The experimental set-up provided a low background by using linearly polarized monoenergetic photon beam, improving the signal-to-noise ratio. The experimental cross-sections obtained in this work were compared with available experimental data from Scofield [1,2] Krause [3,4] and Scofield and Puri et al. [5,6]. These experimental values closely agree with the theoretical values calculated using Scofield and Krause data, except for the case of Lg, where values measured of this work are slighter higher.

2011-01-01

78

Beam Test of a Prototype Detector Array for the PoGO Astronomical Hard X-Ray/Soft Gamma-Ray Polarimeter  

CERN Document Server

Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument designed to measure polarization from astrophysical objects in the 30-100 keV range, under development by an international collaboration with members from United States, Japan, Sweden and France. To examine PoGO's capability, a beam test of a simplified prototype detector array was conducted at the Argonne National Laboratory Advanced Photon Source. The detector array consisted of seven plastic scintillators, and was irradiated by polarized photon beams at 60, 73, and 83 keV. The data showed a clear polarization signal, with a measured modulation factor of $0.42 \\pm 0.01$. This was successfully reproduced at the 10% level by the computer simulation package Geant4 after modifications to its ...

2005-01-01

79

Study of penetration depth for V"+ with low energy implanted in peanut seeds  

International Nuclear Information System (INIS)

The penetration depth and concentration distribution for vanadium ions with low energy implanted into the dry peanut seeds is determined by scanning electron microscope and X-ray energy dispersion spectrometer. The results show that the depth-concentration distribution is a Gaussian distribution with a long tail and the maximum penetration depth is about 13.6 #mu#m for V"+ with 200 keV in cotyledon of the peanut. The experimental result of the implanted V"+ range in the peanut seeds is compared with the calculating value of the TRIM95

2002-11-01

80

Influence of changes in the composition of Kh18N10T steel on the results of measurement of its thickness by the radiometric method  

International Nuclear Information System (INIS)

The additional error in measurement of the thickness of Kh18N10T steel for possible changes in composition with an energy of the photons of ionizing radiation of 10-80 keV was evaluated. The desirability of use of a type REIS-I x-ray emitter in measurement of the thickness of steel up to 1 mm is shown. The instrument provides measurement of the thickness of steel in the 0.1-1.0 mm range with a reproducibility of the results with an error not exceeding 0.5-1.0%. The measurement error with corrugations characteristic of bellows does not exceed 5%.

81

CMOS/SOI hardening at 100 MRAD (SiO_2)  

International Nuclear Information System (INIS)

Hardened CMOS/SOI 29101 microprocessor, elementary cells and transistor shave been irradiated at levels between 10 Mrad(SiO_2) and 1 Grad(SiO_2) ("6"0Co and 10 keV x-rays). SIMOX buried oxide behavior in the range of 100 Mrad(SiO_2) and a channel-stopped MOS/SOI structure avoiding lateral leakage current are presented. These two items indicate the feasibility of a CMOS/SOI technology operating in the hundred Mrad(SiO_2) range.

1990-07-16

82

Chemical and morphological characterization of mesoporous material supported copper oxide nanoparticles for potential application  

British Library Electronic Table of Contents (United Kingdom)

SBA-15 supported nano-scaled copper oxide was synthesized by impregnation method via ultrasonic-assisted route. The removal test from gas mixture containing 0.1?vol.% hydrogen sulfide was carried out over this material at atmospheric conditions. The effects of the chemical nature of copper oxide and the textural properties of the material on removal capacity were studied. The materials before and after the removal test were analyzed by nitrogen adsorption, X-ray diffraction, Transmission Electron Microscope, X-ray photoelectron Spectroscopy, Fourier Transform Infrared Spectrometer and Inductive Coupled Plasma. The results showed that copper species are located predominantly in mesopore channels, existing as copper oxide nanoparticles. Mesopores are active sites for removal reaction. The ou...

2011-01-01

83

Beryllium coating on JET Inconel tiles  

International Nuclear Information System (INIS)

Full text: Institute for Nuclear Research, Pitesti-Mioveni, Romania in direct cooperation with the National Institute for Laser, Plasma and Radiation Physics, Magurele, Bucharest studied and prepared for coating more than 1000 tiles made of Inconel with 7-9 #mu#m of beryllium for nuclear fusion applications at JET, Culham, UK. The principles of manufacturing processes using thermal evaporation and plasma ignited in pure metal vapors as well as by Thermionic Vacuum Arc (TVA) method and the properties of the Ni and Be coatings are presented. The prepared beryllium layers were characterized by scanning electron microscopy, transmission electron microscopy, X-ray diffraction, X-ray photoelectron spectroscopy and atomic force microscopy. (authors)

2009-10-12

84

A novel single-step synthesis of N-doped TiO"2 via a sonochemical method  

British Library Electronic Table of Contents (United Kingdom)

A novel single-step synthetic method for the preparation of anatase N-doped TiO"2 nanocrystalline at low temperature has been devoleped. The N-doped anatase TiO"2 nanoparticles were synthesized by sonication of the solution of tetraisopropyl titanium and urea in water and isopropyl alcohol at 80^oC for 150min. The as-prepared sample was characterized by X-ray diffraction, transmission electron microscopy, X-ray photoelectron spectroscopy and UV-vis absorption spectrum. The product structure depends on the reaction temperature and reaction time. The photocatalytic activity of the as-prepared photocatalyst was evaluated via the photodegradation of an azo dye direct sky blue 5B. The results show that the N-doped TiO"2 nanocrystalline prepared via sonication exhibit an excellent photocatalytic...

2011-01-01

85

Microprobe RBS analysis of localized processed areas by FIB etching and deposition  

International Nuclear Information System (INIS)

Localized beam-processed areas using chemical reactions induced by a 30 keV Ga"+ focused ion beam (FIB) with and without I_2 (etching) and (CH_3)_3CH_3C_5H_5Pt gases (Pt deposition) have been analyzed using a 300 keV Be"2"+ microprobe with a beam spot size of 50-80 nm. The analyzed results have been compared with energy dispersive X-ray (EDX) analysis using an electron beam. The EDX analysis only indicated incorporated impurities at high fluence such as Ga, Pt and C, while microprobe RBS analysis could detect residual iodine with low concentration which couldn't be detected by EDS analysis because of the lower sensitivity of the EDX analysis for heavy atoms.

2001-07-01

86

Diffraction applications using the energy dispersive beamline X6A at the National Synchrotron Light Source  

Energy Technology Data Exchange (ETDEWEB)

The energy dispersive beamline X6A at the National Synchrotron Light Source employs a curved crystal monochromator (polychromator) which focuses a range ([similar to]1 keV) of x-ray energies into a narrow (100--120 [mu]m) line image. Although this beamline was constructed primarily for time-dependent EXAFS experiments, we have begun to explore the use of this instrument for energy dispersive diffraction experiments with different types of sample including macromolecular crystals. The tunability ([ital E]=6.5 to 21 keV) and flexibility ([Delta][ital E]=100--1000 eV) of the instrument makes the beamline ideal as a test bed for the application of polychromatic single-crystal diffraction techniques to different chemical or biological materials.

1995-02-01

87

Determination of ratios of emission probabilities of Auger electrons and K-L-shell radiative vacancy transfer probabilities for 17 elements from Mn to Mo at 59.5keV  

Energy Technology Data Exchange (ETDEWEB)

The measurements of the K X-ray intensity ratio I(K{sub {beta}})/I(K{sub {alpha}}) for the 17 elements Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Br, Rb, Sr, Y, Zr, Nb and Mo have been done following ionization by 59.5keV {gamma}-rays from a {sup 241}Am point source. Ratios of emission probabilities of Auger electrons and the vacancy transfer coefficients have been extracted in terms of the intensity ratios. It is found that the present results agree well with earlier fitted values and the semi-empirical values.

2006-01-15

88

X-ray zone plate fabrication using a focused ion beam  

Energy Technology Data Exchange (ETDEWEB)

An x-ray zone plate was fabricated using the novel approach of focused ion beam (FIB) milling. The FIB technique was developed in recent years, it has been successfully used for transmission electron microscopy (TEM) sample preparation, lithographic mask repair, and failure analysis of semiconductor devices. During FIB milling, material is removed by the physical sputtering action of ion bombardment. The sputter yield is high enough to remove a substantial amount of material, therefore FIB can perform a direct patterning with submicron accuracy. The authors succeeded in fabricating an x-ray phase zone plate using the Micrion 9500HT FIB station, which has a 50 kV Ga{sup +} column. Circular Fresnel zones were milled in a 1.0-{micro}m-thick TaSiN film deposited on a silicon wafer. The outermost zone width of the zone plate is 170 nm at a radius of 60 {micro}m. An achieved aspect ratio was 6:1.

2000-08-16

89

Study on pyrolysing behavior of NiO-SDC composite particles prepared by spray pyrolysis technique  

Energy Technology Data Exchange (ETDEWEB)

The NiO-samaria doped ceria (SDC) composite powders were prepared by spray pyrolysis technique at temperatures between 400 and 1000 C. The variation of the particle structure was investigated by X-ray diffraction (XRD), X-ray absorption fine structure (XAFS), scanning electron microscope (SEM), and transmission electron microscope (TEM)-energy-dispersive X-ray spectroscopy (EDS). The thermal analysis of raw materials was also carried out. The following facts became clear in this study. Ceria and nickel have been already separated at 400 C. Samaria is amorphous phase below 600 C, and is dissolved in ceria at 600 C or higher. Samaria is distributed uniformly inside the particles before dissolving in ceria. The thermal decomposition temperatures of metal nitrate are: cerium < nickel < samarium. The results of these analyses were explained without contradiction. It was found that it is ...

2007-03-15

90

Comparison of two dose-area-product ionization chambers with different conductive surface coating for over-table and under-table tube configurations  

Energy Technology Data Exchange (ETDEWEB)

A custom-built graphite-coated transmission ionization chamber is compared to the VacuDAP 2001 (VacuTec, Dresden, Germany), which has transparent conductive electrodes. A study was made of the dependence of response on x-ray tube potential for both types of chamber under identical conditions of exposure using over-table and under-table x-ray tubes. Since the calibration factor is the dose-area product of the radiation incident on the patient per chamber reading, it depends on the intrinsic response of the chamber as well as the effect of material in the beam between the x-ray tube and patient. Differences of about 20% were measured between the intrinsic and the over-table calibration factors and between the over-table and the under-table calibration factors for both chambers. The VacuDAP display is specifically calibrated for the over-table condition and would overstate the actual DAP in the under-table ...

2000-03-01

91

Application of grazing incidence x-ray diffraction to polymer blends  

Energy Technology Data Exchange (ETDEWEB)

The physical properties of polymer blends consisting of one or more crystallizable components are affected by the microstructure of these materials. In particular, the degree of crystallinity can be influenced by processing parameters, and the crystallinity, as well as the phase distribution, may vary as a function of depth through an injection molded part Conventional x-ray diffraction techniques can provide information regarding both phase composition and degree of crystallinity, but, because of the relative transparency of these materials to wavelengths generally available in the laboratory, these techniques provide information representative of only the bulk. By employing parallel beam optics at varying grazing incidence angles, the x-ray sampling depth can be varied without loss of resolution. This technique can be used to vary the effective analysis depth from the top several hundred angstroms for low razing incidence to centimeters for ...

1992-01-01

92

Application of grazing incidence x-ray diffraction to polymer blends  

Energy Technology Data Exchange (ETDEWEB)

The physical properties of polymer blends consisting of one or more crystallizable components are affected by the microstructure of these materials. In particular, the degree of crystallinity can be influenced by processing parameters, and the crystallinity, as well as the phase distribution, may vary as a function of depth through an injection molded part Conventional x-ray diffraction techniques can provide information regarding both phase composition and degree of crystallinity, but, because of the relative transparency of these materials to wavelengths generally available in the laboratory, these techniques provide information representative of only the bulk. By employing parallel beam optics at varying grazing incidence angles, the x-ray sampling depth can be varied without loss of resolution. This technique can be used to vary the effective analysis depth from the top several hundred angstroms for low razing incidence to centimeters for ...

1992-10-01

93

Alloys and oxides on carbon-supported Pt-Sn electrocatalysts for ethanol oxidation  

Energy Technology Data Exchange (ETDEWEB)

This work reports studies of ethanol oxidation on Pt-Sn/C catalysts with nearly the same particle size and identical overall composition having different amounts of oxide and alloyed phases. Results of characterization of physical properties by transmission electron microscopy (TEM), X-ray diffraction (XRD), differential scanning calorimetry (DSC), X-ray photoelectron spectroscopy (XPS), and in situ dispersive X-ray absorption spectroscopy (DXAS) are presented. The variation in the amount of oxide and alloyed phases, promoted by heat treatments in mild temperature conditions, does not produce any significant particle growth. Cyclic voltammetry and oxidation of adsorbed CO in acid medium are used to probe the surface conditions. Data on the electrocatalytic activity towards ethanol oxidation, obtained by potential sweeps and chronoamperometry, are discussed and correlate well with the physical ...

2010-06-01

94

Peculiarities of Swift Proton Transmission through Tapered Glass Capillaries  

International Nuclear Information System (INIS)

A study of the 150-300 keV proton beam transmission through glass (borosilicate) tapered capillaries with different diameters of the input and output of the capillary was performed. The focusing effect was observed. The areal density of the transmitted beam is enhanced by approximately 20 times. It was shown that changing a taper angle from 0.5 deg to 1.7 deg evidences the increase of the transmission coefficient more than by 300 times keeping the initial energy spectrum of ions. (author)

2011-07-01

95

X-ray micro-spectroscopy: a tool for micro-scale radionuclide speciation in heterogeneous nuclear waste repository materials  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: Large-scale problems such as nuclear waste disposal are increasingly recognized to be interconnected to small scale-mechanisms. Thus, synchrotron-based high-resolution analytical X-ray probes become important tools for exploring the micro-scale chemical reactivity of heterogeneous barrier materials used in nuclear waste repositories. In this study the layout of the micro-XAS beamline at the Swiss Light Source (SLS) will be presented. The beamline is optimized towards micro beam experiments ({approx}1 x 1 {mu}m{sup 2}) in the hard-X-ray regime (4 - {approx}22 keV) and allows to combine micro X-ray fluorescence (micro-XRF), micro X-ray absorption spectroscopy (micro- XAS), and micro X-ray diffraction (micro-XRD) investigations with radioactive samples. Furthermore, the potential of micro-XRF/XAS/XRD for acquiring spatially ...

2005-07-01

96

Validity of the CT to attenuation coefficient map conversion methods  

International Nuclear Information System (INIS)

The most important commercialized methods of attenuation correction in SPECT are based on attenuation coefficient map from a transmission imaging method. The transmission imaging system can be the linear source of radioelement or a X-ray CT system. The image of transmission imaging system is not useful unless to replacement of the attenuation coefficient or CT number with the attenuation coefficient in SPECT energy. In this paper we essay to evaluate the validity and estimate the error of the most used method of this transformation. The final result shows that the methods which use a linear or multi-linear curve accept a error in their estimation. The value of mA is not important but the patient thickness is very important and it can introduce a error more than 10 percent in the final result.

2004-04-27

97

X-Ray Fluorescence Analysis of Composite Propellants for ...  

Science.gov (United States)

... The constancy of the X-ray intensity ratio for each element in Table 8 as the X-ray tube settings were changed shows the excellent compensating ...

1977-06-03

98

Radionuclide X-ray fluorescence analysis. 1: Excitation of X-ray fluorescense radiation by nuclear radiation  

Science.gov (United States)

The principles of radionuclide excitation of X-ray fluorescence radiation and its application in

1972-01-01

99

Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation  

Science.gov (United States)

This investigation describes the technique for the detection of the X-ray fluorescent radiation

1972-01-01

100

Visibility of tumor-like details in inline phase contrast mammography using quasimonochromatic X-ray sources  

Energy Technology Data Exchange (ETDEWEB)

A new generation of quasimonochromatic high-flux X-ray sources, based on the X-ray radiation produced through Compton scattering between an electron beam and a laser beam, is under development. One of the possible applications of this source is inline phase contrast mammography, based on the observation of the edge-enhancement effect that can be observed at the border of structures inside the breast in images produced using a partially or totally coherent X-ray beam. In this work we present the results of a set of simulations of inline phase contrast mammography using typical inverse Compton scattering sources parameters. The simulated sample was a tumour-like mass having spherical shape, diameter between 200 {mu}m and 5 mm, placed inside a breast-like matrix, 4 cm thick, and a standard composition of 50% glandular tissue and 50% adipose tissue. We discuss the minimum requirements for mammography using inverse Compton ...

2009-09-01

101

Valence-electron configuration of Ti and Ni in Ti{sub x}Ni{sub 1-x} alloys from K{beta}-to-K{alpha} X-ray intensity ratio studies  

Energy Technology Data Exchange (ETDEWEB)

K{beta}-to-K{alpha} X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of Ti{sub x}Ni{sub 1-x} (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi {sup 109}Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured K{beta}-to-K{alpha} X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other ...

2010-06-15

102

PROBING THE ORIGINS OF THE C IV AND Fe K? BALDWIN EFFECTS  

International Nuclear Information System (INIS)

We use UV/optical and X-ray observations of 272 radio-quiet Type 1 active galactic nuclei and quasars to investigate the C IV Baldwin Effect (BEff). The UV/optical spectra are drawn from the Hubble Space Telescope, International Ultraviolet Explorer and Sloan Digital Sky Survey archives. The X-ray spectra are from the Chandra and XMM-Newton archives. We apply correlation and partial-correlation analyses to the equivalent widths (EWs), continuum monochromatic luminosities, and ?ox, which characterizes the relative X-ray to UV brightness. The EW of the C IV ?1549 emission line is correlated with both ?ox and luminosity. We find that by regressing l?(2500 A) with EW(C IV) and ?ox, we can obtain tighter correlations than by regressing l?(2500 A) with only EW(C IV). Both correlation and regression analyses imply that l?(2500 A) is not the only factor controlling the changes of EW(C IV); ?ox (or, equivalently, the soft ...

2009-09-01

103

X-ray microanalysis of Al/Zr multilayers in the transmission electron microscope  

International Nuclear Information System (INIS)

A one-nanometer scale transmission electron microscope electron probe X-ray microanalysis characterization of as-deposited and annealed aluminum--11.5 at.% zirconium multilayer samples in cross-section synthesized by magnetron sputtering is reported on here. Composition line profiles were acquired across Zr layers in as-deposited material and samples isochronally annealed in a differential scanning calorimeter to temperatures of 290 C and 485 C. A spatial resolution of approximately 1.5 to 2.0 nm was achieved in these experiments and will be improved by deconvolution of the instrumental electron probe function from the data. The as-deposited structure consisted of crystalline Al and Zr layers with thin amorphous layers at the Al/Zr interfaces. The amorphous interface layers increased in thickness upon annealing to 290 C. Additionally, at 290 C a metastable cubic alloy forms at the Zr deposited on Al interface. Upon heating to 485 C a multilayer ...

1997-04-04

104

Cross-sectional Specimen Preparation and Observation of a Plasma Sprayed Coating Using a Focused Ion Beam/Transmission Electron Microscopy System.  

Science.gov (United States)

A focused ion beam (FIB) technique was applied to cross-sectional specimen preparation to observe an interface between a plasma sprayed coating and an aluminum (Al) substrate by transmission electron microscopy (TEM). The surface of the sprayed coating film has a roughness of several tens of microns. Sputter rates for the coating film and the substrate are greatly different. The rough surface and the difference in sputter rate cause problems in making TEM specimens with smooth side walls. The top surface of the coating film was planerized by the FIB before fabricating the TEM specimen. The interfaces were investigated by TEM and energy-dispersive X-ray (EDX) analysis. The TEM observation revealed that there is a 10 nm thick amorphous layer at the interface between the coating film and substrate. The coating film consists of two kinds of sublayers with bright and dark contrast. The bright contrast sublayers were amorphous layers with thickness ...

2000-05-01

105

The XMM-Newton wide-field survey in the COSMOS field. IV: X-ray spectral properties of Active Galactic Nuclei  

CERN Document Server

We present a detailed spectral analysis of point-like X-ray sources in the XMM-COSMOS field. Our sample of 135 sources only includes those that have more than 100 net counts in the 0.3-10 keV energy band and have been identified through optical spectroscopy. The majority of the sources are well described by a simple power-law model with either no absorption (76%) or a significant intrinsic, absorbing column (20%).As expected, the distribution of intrinsic absorbing column densities is markedly different between AGN with or without broad optical emission lines. We find within our sample four Type-2 QSOs candidates (L_X > 10^44 erg/s, N_H > 10^22 cm^-2), with a spectral energy distribution well reproduced by a composite Seyfert-2 spectrum, that demonstrates the strength of the wide field XMM/COSMOS survey to detect these rare and underrepresented sources.

2006-01-01

106

Soft X-ray holography of FIB nanostructured Co/Pt multilayers  

International Nuclear Information System (INIS)

Focused Ion Beam (FIB) milling is a powerful tool to produce ordered magnetic nanostructures. However, it is impossible to produce out-of-plane magnetized nanoscale structures from multilayer films by direct FIB writing. Co/Pt multilayers exhibit an out-of-plane easy axis due to strong perpendicular interface anisotropy. The interface contribution is known to be very sensitive to high energy ion irradiation. In case of 30 keV Ga ions it needs less than one ion per 100 surface atoms to destroy the perpendicular interface anisotropy. We demonstrate how this problem can be overcome by milling a Co/Pt multilayer, which has been deposited on a SiN membrane, from the rear side, through the SiN. The effect of the ions is determined as a function of applied dose utilizing the domain structure imaged by soft X-ray holography. When the magnetic material is removed we find only a very narrow range of destruction around the holes in contrast to the ...

2009-03-22

107

Radioanalytical determination of chromium in welding fumes  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis and fast neutron activation analysis were used for the determination of chromium. The excitation source for X-ray fluorescence analysis was a ring-shaped "2"4"1Am source with an activity of 18.5x10"9 Bq. SYNPOR filters of 35 mm in diameter were used for the measurement. The 5.414 keV Cr peak was measured with a Si(Li) detector. The sensitivity was 0.05 mg for a period of measurement of 1000 s. A neutron generator with an emission of 10"9 s"-"1 was used as the source of fast neutrons. "5"2V and "5"3V, the products of nuclear reaction with Cr, were measured gamma spectrometrically with a Ge(Li) detector. The sensitivity for Cr is 0.015 mg, in the presence of Mn which causes interference the sensitivity is a mere 0.075 mg. The mentioned methods were used to determine total Cr and Cr(VI) in welding aerosols. It was found that the most toxic form, i.e., Cr(VI), is released during manual ...

1985-01-01

108

Performance testing of selected types of electronic personal dosimeters used in Sudan  

International Nuclear Information System (INIS)

Measurements were carried out for calibration and performance testing of a set of 10 electronic personal dosimeters (EPDs) at the Secondary Standard Dosimetry Laboratory of Sudan. Calibrations were carried out at three X-ray beam qualities described in ISO standard 4037 in addition to 137Cs and 60Co gamma ray beams. The experimental was performed with EPDs mounted on ICRU Slab phantom. X-ray and ?-ray beams were characterized in terms of air kerma free-in-air which were converted to the known delivered personal dose equivalent, Hp(10) using appropriate the air kerma to personal dose equivalent conversion coefficients. Dosimeters tested showed excellent energy and angular response and relative error of indication within the recommended limit for photon energies from 65 keV to 1.25 MeV. The study showed encouraging results for using electronic dosimeters in personal dosimetry.

2010-12-01

109

K{beta}-to-K{alpha} X-ray intensity ratio studies on the changes of valence electronic structures of Ti, V, Cr, and Co in their disilicide compounds  

Energy Technology Data Exchange (ETDEWEB)

K{beta}-to-K{alpha} X-ray intensity ratios of Ti, V, Cr, and Co in pure metals and their disilicide compounds have been measured following excitation by 59.54 keV {gamma}-rays from a 200 mCi {sup 241}Am point-source. The K{beta}-to-K{alpha} intensity ratios of all these metals in the disilicide compounds are found to be less than the corresponding ratios for pure metals. Comparison of the measured K{beta}-to-K{alpha} intensity ratios for the disilicides and pure metals with the multiconfiguration Dirac-Fock calculations indicates increase of the 3d electron populations of Ti, V, Cr, and Co in the disilicides from their pure metal values suggesting the rearrangement of electrons between 3d and 4s states of the individual metal atom. This rearrangement is found to be opposite to that observed in our previously reported work on NiSi{sub 2} and CuSi{sub 2}.

1999-06-01

110

K#beta#-to-K#alpha# X-ray intensity ratio studies on the changes of valence electronic structures of Ti, V, Cr, and Co in their disilicide compounds  

International Nuclear Information System (INIS)

K#beta#-to-K#alpha# X-ray intensity ratios of Ti, V, Cr, and Co in pure metals and their disilicide compounds have been measured following excitation by 59.54 keV #gamma#-rays from a 200 mCi "2"4"1Am point-source. The K#beta#-to-K#alpha# intensity ratios of all these metals in the disilicide compounds are found to be less than the corresponding ratios for pure metals. Comparison of the measured K#beta#-to-K#alpha# intensity ratios for the disilicides and pure metals with the multiconfiguration Dirac-Fock calculations indicates increase of the 3d electron populations of Ti, V, Cr, and Co in the disilicides from their pure metal values suggesting the rearrangement of electrons between 3d and 4s states of the individual metal atom. This rearrangement is found to be opposite to that observed in our previously reported work on NiSi_2 and CuSi_2.

1999-06-01

111

Design of a GaAs X-ray imaging sensor with integrated HEMT readout circuitry  

CERN Document Server

A new monolithic semi-insulating (SI) GaAs sensor design for X-ray imaging applications between 10-100keV has been proposed. Monolithic pixel detectors offer a number of advantages over hybrid bump-bonded detectors, such as high device yield, low costs and are easier to produce large scale arrays. In this thesis, an investigation is made of the use of a SI GaAs wafer as both a detector element and substrate for the epitaxially grown High Electron Mobility Transistors (HEMTs). The design of the HEMT transistors, optimised for this application, were produced with the aid of the Silvaco 'Virtual Wafer Fab' simulation package. It was determined that the device characteristics would consist of a small positive threshold voltage, a low off-state drain current and high transconductance. The final HEMT transistor design, that would be integrated to a pixel detector, had a threshold voltage of 0.17V, an off-state leakage current of approx 1nA and a ...

2002-01-01

116

Synthesis of CdSe nanoparticles and their effect on the antioxidant activity of Spirulina platensis and Porphyridium cruentum cells  

International Nuclear Information System (INIS)

Single-crystalline cadmium selenide nanoparticles were obtained using high-temperature solution phase synthesis (HTSPS) synthesis. X-Ray powder diffraction and transmission electron microscopy were used to confirm the crystallinity and morphology of the resulting nanoparticles. To study the action of CdSe on antioxidant activity, we selected two biotechnological important strains of microalgae: cyanobacteria Spirulina platensis and red microalgae Porphyridium cruentum. In the case of Porphyridium cruentum, the obtained results demonstrated an increase in the productivity. For Spirulina platensis, the presence of the compound in the cultivating medium decreased the productivity of cyanobacteria.

2011-07-07

117

Synthesis and characterization of Rosebengal/folicacid-functionalized multiwall carbon nanotubes  

British Library Electronic Table of Contents (United Kingdom)

Multiwall carbon nanotubes (MWCNTs) were functionalized with a photosensitizer, rosebengal (RB), and folicacid (FA), an anti-cancer drug simultaneously and individually, which was characterized with various analytical instruments like Fourier Transform Iinfrared (FTIR) spectroscopy, UV?Vis spectroscopy, Thermogravimetric analysis (TGA), Photoluminescence (PL) spectroscopy, X-ray photoelectron spectroscopy (XPS), and Transmission electron microscopy (TEM). FTIR spectra confirmed the chemical modification of MWCNT. The chemical functionalization of MWCNT with RB was further supported by UV?Vis and PL spectra.

2011-01-01

118

Structure and electrical resistance of dispersion-strengthened vacuum-deposited Cu?Al2O3 nanocomposites  

British Library Electronic Table of Contents (United Kingdom)

Methods of X-ray diffraction and transmission electron microscopy were used to study the microstructure of dispersion-strengthened Cu-Al2O3 nanocomposites obtained by the method of simultaneous deposition of Cu and Al2O3 from the vapor phase. The effect of the size of particles of the oxide (Al2O3) and of their content on the electrical resistance of the composite has been considered. The results obtained make it possible to suppose that the main structural factor that determines the electrical resistance of the composite are nanodispersed particles of Al2O3 with a size of less than 20 nm.

2011-01-01

119

Structural and magnetic studies on the enhancement of the giant magnetoimpedance by ion irradiation  

British Library Electronic Table of Contents (United Kingdom)

The mechanism of abrupt increase of the giant magneto impedance (GMI) ratio in the ion irradiated Co-based amorphous ribbon has been investigated. The grazing incident X-ray diffraction and transmission electron microscope were used to characterize the samples before and after ion irradiation. The GMI-ratio considerably increased in the ion irradiated samples and the GMI response showed strong dependence on the driving frequencies. The Barkhausen noise (BN) signals are increased for the Ar ion irradiated sample with dose of 1x10^1^7 ion/cm^2. The results are interpreted in terms of GMI variation associated with domain wall dynamics.

2011-01-01

120

Direct Comparison of the X-Ray Emission and Absorption of Cerium Oxide  

Energy Technology Data Exchange (ETDEWEB)

Bremstrahlung Isochromat Spectroscopy (BIS). The XES spectra were collected using a Specs electron gun for the excitation and the XES 350 grating monochromator and channel plate system from Scienta as the photon detection. Spectra were collected in 'normal mode,' where the electron gun kinetic energy (KE) and the energy position of the center of the channel plate were both fixed and the energy distribution in the photon (hv) spectrum was derived from the intensities distributed across the channel plate detector in the energy dispersal direction. The polycrystalline Ce sample was oxidized by exposure to air at ambient pressures. After introduction to the ultra-high vacuum system, the oxidized sample was bombarded with Ar, to clean the topmost surface region and stabilize the surface and near surface regions. Although CeO{sub 2} would be the thermodynamically preferred composition in an oxygen rich environment, the combination of a vacuum environment and ion etching may ...

2010-11-24

121

The X-ray Ordinance  

International Nuclear Information System (INIS)

The sections and provisions of the X-ray Ordinance of January 8, 1987 are discussed which are of relevance to dental radiology. (DG).

122

Transmission electron microscopy study of plasma nitriding of electroplated chromium coating  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the influence of plasma nitriding at temperature 720 deg. C for 20 h on the surface microstructure and interface microstructure of electroplated chromium coating was investigated. In these conditions, interdiffusion, mixing and reaction phenomena of elements originating from the substrate and coating material are more likely to occur, thus increasing the bonding strength between the coating and carbon steel substrate. The change of the structures from the substrate side to the coating surface, and the effect of the substrate steel on the interface structure were studied by cross-sectional transmission electron microscope observation (XTEM). The nitride layer formed on the surface was analyzed by X-ray diffraction method (XRD). After treatment at above conditions a 6-7 {mu}m thick nitride compound layer was formed in surface region and the same thick carbide compound layer was also formed in the interface region between ...

2003-02-28

123

Transmission electron microscopy study of plasma nitriding of electroplated chromium coating  

International Nuclear Information System (INIS)

In this paper, the influence of plasma nitriding at temperature 720 deg. C for 20 h on the surface microstructure and interface microstructure of electroplated chromium coating was investigated. In these conditions, interdiffusion, mixing and reaction phenomena of elements originating from the substrate and coating material are more likely to occur, thus increasing the bonding strength between the coating and carbon steel substrate. The change of the structures from the substrate side to the coating surface, and the effect of the substrate steel on the interface structure were studied by cross-sectional transmission electron microscope observation (XTEM). The nitride layer formed on the surface was analyzed by X-ray diffraction method (XRD). After treatment at above conditions a 6-7 #mu#m thick nitride compound layer was formed in surface region and the same thick carbide compound layer was also formed in the interface region between ...

2003-02-28

124

Nanostructured nickel ferrite: A liquid petroleum gas sensor  

British Library Electronic Table of Contents (United Kingdom)

The present investigation deals with the synthesis of nanostructured nickel ferrite (NiFe2O4) and their liquid petroleum gas-sensing characteristics. The 15-20nm size nickel ferrite has been synthesized at 700degreeC by a simple molten-salt route using sodium chloride as grain growth inhibitor. These nanoparticles exhibit significantly high response towards liquid petroleum gas (LPG) in comparison with ethanol vapor, hydrogen sulfide, ammonia and hydrogen. The gas response towards various gases at their 200ppm concentrations is investigated at 200-450degreeC. Different characterization techniques have been employed, such as differential thermal analysis, X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM) and high resolution transmission elec...

2009-01-01

125

Electronics Personal Dosemeter (EPD-N) Test and Evaluation Report  

Energy Technology Data Exchange (ETDEWEB)

Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization then used at another site.

2003-04-08

126

Determination of Proper Peaking Time for Ultra Lege detector at Medium Energies  

International Nuclear Information System (INIS)

Reducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the optimum peaking time for particular detector systems is important. For this purpose, pure Se and Zn elements were excited by 59.5 keV ?-rays from a 50 mCi 241Am annular radioactive source in this study. The characteristic x-rays emitted from pure Se and Zn elements were detected by using an ultra low energy Ge (Ultra-LEGe) detector connecting Tennelec TC 244 spectroscopy amplifier at different peaking time modes. Overall pulse widths were determined by HM 203-7 oscilloscope connecting amplifier. The proper peaking time for ultra low energy germanium detector (Ultra-LEGe) is determined about 4 ?s.

2008-08-25

127

Comparative evolution of various CCD image sensors hardening techniques with ionizing radiation  

International Nuclear Information System (INIS)

This paper reviews various techniques to harden Charged Coupled Device (CCD) sensors and the results after irradiation of three Thomson n buried channel CCDs having a different degree of hardening. It describes the major irradiation effects on CCD performances and it makes a comparison of the results between the different hardening levels. It shows good results on dark voltage after ionizing radiation for TH 7863M device hardened both by design and by operating conditions (MPP mode) with respect to the standard device TH 7863A. The irradiations were performed with "6"0Co or X-ray (10 keV) sources on devices in operating mode. (author). 3 refs., 8 figs.

128

Nuclear radiation detectors on II-VI compounds  

International Nuclear Information System (INIS)

Nuclear radiation detectors in integral execution were produced by successive epitaxial growth from vapor phase of Zn Te and Cd Se thin layers onto scintillating Zn Se (Te) crystals. The irradiation of combined Zn Se (Te) - Zn Te - Cd Se detectors by Cu_K_a X-rays leads to the appearance of photoreceiver e.m.f., which tends to saturation with the increase of X-ray radiation dose reaching the value of 0.34-0.40 V at 200 R/min. The short circuit current dependence of irradiation dose power is linear. The matching factor for detectors with Zn Te-Cd Se photoreceivers with different doping levels is 0.68-0.92. The absolute monochromatic sensitivity is 0.32-0.35 m A/m W at a quantum efficiency 0.58-0.61 and a time constant 2 x 10"-"4 s. The calculated dose sensitivity for Zn Se(Te)-Zn Te-Cd Se combined detectors at the irradiation with X-rays having effective energy 8.86 keV gives the value 3.9 x 10"-"7 ...

1993-10-13

129

Element distribution in the brain sections of rats measured by synchrotron radiation X-ray fluorescence  

International Nuclear Information System (INIS)

The concentration of trace elements in brain sections was measured by synchrotron radiation X-ray fluorescence. The relative concentration was calculated by means of the normalization of Compton scattering intensity approximately 22 keV, after the normalization for collecting time of X-ray spectrum and the counting of the ion chamber, and subtracting the contribution of the polycarbonate film for supporting sample. Furthermore, the statistical evaluation of the element distribution in various regions of the brain sections of the 20-day-old rats was tested. For investigating the distribution of elements in the brain of iodine deficient rats, Wistar rats were fed with iodine deficient diet and deionized water (ID group). The rats were fed the same iodine deficient diet, but drank KIO_3 solution as control (CT group). The results showed that the contents of calcium (Ca) in thalamus (TH) and copper (Cu) and iron (Fe) in ...

2004-02-27

130

Phase imaging using laser-produced X-ray sources  

International Nuclear Information System (INIS)

A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. The authors established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profile of the laser-produced x-ray on x-ray phase imaging. Though the laser-produced x-ray pulse duration is short and incoherent, the analysis confirms that the current x-ray phase imaging theory still holds for laser-produced x-ray phase imaging

2000-08-01

131

Effective atomic numbers and electron densities of some biologically important compounds containing H, C, N and O in the energy range 145-1330 keV  

International Nuclear Information System (INIS)

A semi-empirical relation which can be used to determine the total attenuation cross sections of samples containing H, C, N and O in the energy range 145-1332 keV has been derived based on the total attenuation cross sections of several sugars, amino acids and fatty acids. The cross sections have been measured by performing transmission experiments in a narrow beam good geometry set-up by employing a high-resolution hyperpure germanium detector at seven energies of biological importance such as 145.4 keV, 279.2 keV, 514 keV, 661.6 keV, 1115.5 keV, 1173.2 keV and 1332.1 keV. The semi-empirical relation can reproduce the experimental values within 1-2%. The total attenuation cross sections of five elements carbon, aluminium, titanium, copper and zirconium measured in the same experimental set-up at the ...

2006-09-28

132

Synthesis of novel high-voltage cathode material LiCoPO{sub 4} via rheological phase method  

Energy Technology Data Exchange (ETDEWEB)

For the first time, rheological phase method, a simple and effective route, is applied to synthesize novel cathode material LiCoPO{sub 4}. X-ray diffraction spectrometer (XRD), X-ray photoelectron spectrometer (XPS), transmission electron microscope (TEM) and electrochemical impedance spectroscopy (EIS) are taken to investigate this material, respectively. XRD figure shows that the rheological sample is better crystallized than the solid-state one. XPS result of the rheological sample exhibits that the valence of Co is 2+. TEM images show that better dispersed particles with smaller size can be formed by rheological method comparing to the solid-state route. Charge-discharge test is carried out in the range of 3.0-5.0 V at 0.2 mA cm{sup -2}. The initial discharge capacity for rheological phase and solid-state powder is 71.5 and 30.9 mAh g{sup -1}, respectively. The better electrochemical property should be ascribed to the ...

2010-07-23

133

Synthesis of novel high-voltage cathode material LiCoPO4 via rheological phase method  

International Nuclear Information System (INIS)

For the first time, rheological phase method, a simple and effective route, is applied to synthesize novel cathode material LiCoPO4. X-ray diffraction spectrometer (XRD), X-ray photoelectron spectrometer (XPS), transmission electron microscope (TEM) and electrochemical impedance spectroscopy (EIS) are taken to investigate this material, respectively. XRD figure shows that the rheological sample is better crystallized than the solid-state one. XPS result of the rheological sample exhibits that the valence of Co is 2+. TEM images show that better dispersed particles with smaller size can be formed by rheological method comparing to the solid-state route. Charge-discharge test is carried out in the range of 3.0-5.0 V at 0.2 mA cm-2. The initial discharge capacity for rheological phase and solid-state powder is 71.5 and 30.9 mAh g-1, respectively. The better electrochemical property should be ascribed to the better crystallized ...

2010-07-23

134

Size-dependent surface plasmon resonance in silver silica nanocomposites  

Energy Technology Data Exchange (ETDEWEB)

Silver silica nanocomposites were obtained by the sol-gel technique using tetraethyl orthosilicate (TEOS) and silver nitrate (AgNO{sub 3}) as precursors. The silver nitrate concentration was varied for obtaining composites with different nanoparticle sizes. The structural and microstructural properties were determined by x-ray diffractometry (XRD), Fourier transform infrared spectroscopy (FTIR) and transmission electron microscopy (TEM). X-ray photoelectron spectroscopic (XPS) studies were done for determining the chemical states of silver in the silica matrix. For the lowest AgNO{sub 3} concentration, monodispersed and spherical Ag crystallites, with an average diameter of 5 nm, were obtained. Grain growth and an increase in size distribution was observed for higher concentrations. The occurrence of surface plasmon resonance (SPR) bands and their evolution in the size range 5-10 nm is studied. For decreasing nanoparticle ...

2008-02-20

135

Processing and characterization of polyethylene/Brazilian clay nanocomposites  

Energy Technology Data Exchange (ETDEWEB)

Nanocomposites containing polyethylene (PE) and montmorillonite clay organically modified (OMMT) with quaternary ammonium salts were obtained via direct melt intercalation. A montmorillonite sample from the Brazilian state of Paraiba was treated with four different types of quaternary ammonium salts. After the treatment, the powder was characterized by X-ray diffraction and scanning electron microscopy. The dispersion and morphologies of OMMT within PE were investigated by X-ray diffraction and transmission electron microscopy. The results revealed the formation of intercalated montmorillonite layers in the PE matrix. The thermal stability and flammability of the PE/montmorillonite clay nanocomposites were measured by thermogravimetry and horizontal burning tests for HB classification, Underwrites Laboratories (UL 94), respectively. It was shown that the samples do not degrade at the processing temperature. By adding only 3 ...

2007-02-15

136

Preparation of Nanocomposite GDC/LSCF Cathode Material for IT-SOFC by Induction Plasma Spraying  

British Library Electronic Table of Contents (United Kingdom)

Homogeneous mixtures of Ce0.8Gd0.2O1.9 (GDC) and La0.6Sr0.4Co0.2Fe0.8O3 (LSCF) nanopowders were successfully synthesized using induction plasma by axial injection of a solution. The resulting nanocomposite powders consisted of two kinds of nanopowders with different mass ratio of GDC/LSCF, such as 3/7 and 6/4. The morphological features, crystallinity, and the phases of the synthesized powders were characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), local energy-dispersive x-ray spectroscopy (EDS) analysis, and x-ray diffraction (XRD). The nanopowders are almost globular in shape with a diameter smaller than 100?nm and their BET specific areas are around 20?m2?g?1. The GDC and LSCF phases are well distributed in the nanopowders. In addition, suspens...

2011-01-01

137

Photocatalytic self-cleaning properties of cellulosic fibers modified by nano-sized zinc oxide  

International Nuclear Information System (INIS)

Nano-sized zinc oxide was synthesized and deposited onto cellulosic fibers using the sol-gel process at ambient temperature. The prepared materials were characterized using several techniques including scanning electron microscopy, transmission electron microscopy, diffuse reflectance spectroscopy, X-ray diffraction and thermogravimetric analysis. X-ray diffraction studies of the ZnO-coated fiber indicate formation of the hexagonal crystal phase which was satisfactory crystallized on the fiber surface. The electron micrographs show formation of zinc oxide nanoparticles within 10-15 nm in size which have been homogeneously dispersed on the fiber surface. The prepared materials show significant photocatalytic self-cleaning activity, which was monitored by diffuse reflectance spectroscopy. The photoactivity was studied upon measuring the photodegradation of methylene blue and eosin yellowish under UV-Vis irradiation. The ...

2011-03-31

138

Nanostructured p-CuIn3Se5/n-CdS heterojunction engineered using simple wet chemical approach at room temperature for photovoltaic application  

British Library Electronic Table of Contents (United Kingdom)

Herein, we report engineering of nanostructured p-CuIn3Se5/n-CdS heterojunction thin film on a glass substrate, which is prepared at room temperature using simple wet chemical approach involving ion exchange reactions between CdS and Cu^+, In^3^+ and Se^2^- ions in alkaline medium. The uniform deposition of heterojunction thin films is achieved by optimizing the pH, temperature and molarity of the reactant bath. The as-deposited thin-films were annealed at 200^oC in air for 1h and further characterized for structural, optical and electrical properties using UV-Vis spectrophotometer, X-ray diffraction (XRD), scanning electron microscopy, transmission electron microscopy, X-ray photoelectron spectroscopy (XPS), Hall effect for type of conductivity, and I-V measurement to investigate the char...

2011-01-01

139

Measuring head for radionuclide X-ray fluorescence analyzer  

International Nuclear Information System (INIS)

The design of a gaging head for a portable radionuclide X-ray fluorescence analyzer is described. The gaging head is designed as a construction unit system which enables the application of lateral reflexion geometry as well as of coaxial geometry. It is designed so that adjustment from one geometry to the other is labour and time saving. The selection of characteristic radiation is performed by a couple of Ross' differential filters. These filters are prepared by a novel technique developed by our laboratory. The filter exchange is effected by the longitudinal move of the couple of filters encapsulated in a holder. The shift of the filters is controlled by means of a triggering mechanism situated in the body of the gaging head handle. This design makes is possible to handle the gaging head during measurements with one hand. A simple interchange of the absorption filter for the transmissive filter allows the operator to avoid any unwanted shift ...

1976-05-21

140

Characterization and reactivity of Fe3O4/FeMnOx core/shell nanoparticles for methylene blue discoloration with H2O2  

British Library Electronic Table of Contents (United Kingdom)

A magnetic core/shell Fe3O4/FeMnOx catalyst was prepared by a simple oxidation-precipitation method. The catalyst was characterized by X-ray diffraction, transmission electron microscope, X-ray photoelectron spectroscopy, Fourier transform infrared spectroscopy, thermogravimetric analysis and cyclic voltammetry. The characterization studies verified that Fe3O4 core was coated with a layer of Fe-Mn oxide. The Fe3O4/FeMnOx was found to be an effective and stable heterogeneous catalyst for the discoloration of methylene blue (MB) in aqueous solution by H2O2. The high catalytic activity is due to the FeMnOx shell, which not only increased the surface hydroxyl groups, but also enhanced the interfacial electron transfer. The discoloration of MB could be due to the decomposition of H2O2 into ?OH ...

2011-01-01

141

Broad-band stigmatic spectrograph for the soft x-ray range  

International Nuclear Information System (INIS)

We describe a panoramic stigmatic spectrograph comprising a grazing-incidence toroidal mirror and a large-aperture free-standing transmission diffraction grating (5000 lines mm-1 ). Two spectrograph versions were constructed, with grazing angles of 7.6 and 40 and the short-wavelength spectral limits near 4 and 1.5 nm. The spectrograph aberrations were studied by numerical ray tracing. The spectrograph was used to record line and quasi-continuous spectra (1.5 - 30 nm) of multiply charged ions in a plasma generated by the second-harmonic pulses of an yttrium aluminate laser (Q = 0.15 J, ? = 5 ns, ? = 0.54 ?m, repetition rate = 0.5 Hz). In combination with a laser-produced plasma radiation source, the arrangement was used to characterise soft x-ray optical components and to generate collimated beams of polarised radiation in the 14 - 20 nm range. (laser applications and other topics in quantum electronics)

1998-09-30

142

A facile one-pot hydrothermal method to prepare europium-doped titania hollow phosphors and their sensitized luminescence properties  

British Library Electronic Table of Contents (United Kingdom)

Monodisperse europium-activated titania hollow phosphors had been synthesized by a facile one-pot hydrothermal method using carbon spheres as hard templates. Samples were characterized by X-ray powder diffraction, transmission electron microscopy, X-ray photoelectron spectroscopy, energy dispersive spectrometer and photoluminescence spectrum. The strongest emission intensity was observed with TiO2:Eu0.2 hollow spheres and TiO2:Eu0.2 hollow spheres calcining at 550^oC. Moreover, the strongest excitation of TiO2:Eu0.2 hollow spheres transferred from 400 to 500^oC and the effective nonradiative energy transfer from the TiO2 hollow spheres host matrix to Eu^3^+ ions crystal field states was realized due to changes of crystalline field in the environment around Eu^3^+ ions occupying Ti^4^+ site...

2010-01-01

143

A facile method for the room-temperature synthesis of water-soluble magnetic Fe3O4 nanoparticles: Combination of in situ synthesis and decomposition of polymer hydrogel  

British Library Electronic Table of Contents (United Kingdom)

We propose and demonstrate a facile room-temperature synthetic method for obtaining water-soluble magnetic Fe3O4 nanoparticles (NPs) by combining the in situ synthesis and decomposition of a magnetic polymer hydrogel. The Fe3O4 NPs with average diameters of 6.3-8.3nm were synthesized in a cross-linked polyacrylamide (PAAm) hydrogel by coprecipitating iron ions. The decomposition of the magnetic polymer hydrogel by an aqueous solution of sodium hydroxide led to the transfer of Fe3O4 NPs into the aqueous medium. The NPs can be dispersed stably in water for more than three months. The Fe3O4 NPs were characterized by X-ray photoelectron spectra (XPS), X-ray powder diffraction (XRD), transmission electron microscope (TEM), and Fourier transform infrared spectroscopy (FT-IR). The saturation magn...

2011-01-01

144

Determination of the Integral/SPI instrumental response and his application to the observation of gamma ray lines in the Vela region; Determination de la reponse instrumentale du spectrometre INTEGRAL/SPI et application a l'observation des raies gamma de la region des Voiles  

Energy Technology Data Exchange (ETDEWEB)

The INTEGRAL/SPI spectrometer was designed to observe the sky in the energy band of 20 keV to 8 MeV. The specificity of instrument SPI rests on the excellent spectral resolution (2.3 keV with 1 MeV) of its detecting plan, composed of 19 cooled germanium crystals; covering an effective area of 508 cm{sup 2}. The use of a coded mask, located at 1.7 m above the detection plan ensures to it a resolving power of 2.5 degrees. The aim of this thesis, begun before the INTEGRAL launch, is made up of two parts. The first part relates to the analysis of the spectrometer calibration data. The objective was to measure and check the performances of the telescope, in particular to validate simulations of the INTEGRAL/SPI instrument response. This objective was successfully achieved. This analysis also highlights the presence of a significant instrumental background noise. Whereas, the second part concentrates on the data analysis of the Vela region ...

2005-01-15

145

X-ray stars in globular clusters  

Science.gov (United States)

The properties and kinetics of x-ray stars in globular clusters are described. Locations, configurations, star evolution, massive close binary systems, various mechanisms, and the x-ray burster properties are included. (JFP)

1977-10-01

146

X-ray dose enhancement effects  

International Nuclear Information System (INIS)

A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.

147

Position-sensitive proportional counter for space-based X-ray imaging studies  

International Nuclear Information System (INIS)

ASTROSAT, India's first dedicated astronomy satellite is slated for launch in 2007. The primary science objective of ASTROSAT is to explore the Universe using broad-band instruments covering optical, UV, soft X-ray and hard X-ray studies

2005-03-01

148

Beam-induced damage on diffractive hard X-ray optics  

UK PubMed Central (United Kingdom)

The issue of beam-induced damage on diffractive hard X-ray optics is addressed. For this purpose a systematic study on the radiation damage induced by a high-power X-ray beam is carried out in both...Full Text Available

2010-11-01

149

Photoacoustic response to X-ray absorption in copper and brass  

Energy Technology Data Exchange (ETDEWEB)

The X-ray photoacoustic spectra of copper and brass (64.7 wt.% Cu and 35.3 wt.% Zn) have been measured at XANES (X-ray absorption near-edge structure) regions using synchrotron radiation. These spectra were compared with optical density of X-ray spectra. It is shown that the information derived from XANES is also included in the X-ray photoacoustic spectrum which reflects the heat production processes in copper and brass. However, the results showed that the increases and changes of the photoacoustic signal were different from those of the X-ray absorption coefficient at XANES regions. (author).

1990-09-01

150

Generation of microwaves and hard X-rays in a flash X-ray tube  

Energy Technology Data Exchange (ETDEWEB)

High interelectrode voltage peaks have been observed simultaneously with the emission of hard X-ray bursts from a flash X-ray tube. The magnitude of the voltage peaks may exceed twice the initial charging voltage. It has also been observed that the discharge emits bursts of X-and P-band microwaves radiation which are coincident with the emission of the hard X-ray bursts. The results indicate that the microwaves and X-rays have a common origin in discharge plasma movements and an acceleration model for electrons in the plasma is presented as one possible explanation of the observed phenomena.

1982-01-01

151

Visible light photocatalytic activity and Photoelectrochemical property of Fe-doped TiO2 hollow spheres by sol?gel method  

British Library Electronic Table of Contents (United Kingdom)

Fe-doped TiO2 hollow spheres (Fe-THs) were synthesized by sol?gel process using carbon spheres as templates. The prepared samples were characterized by X-ray diffraction (XRD), transmission electron microscopy (TEM), UV?vis diffuse reflectance spectrum (DRS), N2 adsorption?desorption isotherms, Electron paramagnetic resonance (EPR) spectroscopy and Photoluminescence emission spectroscopy (PL). UV?vis spectra showed that Fe3+ doping could extend the absorption edge to the visible region. EPR spectra showed that Fe3+ was incorporated into the crystal lattice of TiO2, which could inhibit the recombination of photo-induced electron?hole pairs and improve the photocatalytic activity. The photocatalytic activities of the prepared samples were evaluated for the degradation of dye Reactive Brillia...

2011-01-01

152

Two-step template-free route for synthesis of TiO2 hollow spheres  

British Library Electronic Table of Contents (United Kingdom)

The TiO2 hollow microspheres were prepared by microwave-assisted solvothermal treatment without template. The morphology and the phase of TiO2 hollow microspheres were characterized by X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM), high resolution transmission electron microscopy (HR-TEM), and BET surface areas. The results show that the particles have hollow structures and the shell was covered by nanocrystals and have higher specific surface area. The possible formation mechanism of hollow TiO2 spherical structures has simply been proposed. The activity was evaluated by the photocatalytic degradation of methyl orange (MO). The results show that the particles having specific surface area show higher photocatalytic activity. It can be attribute to the doped ...

2011-01-01

153

Thermal stability of cryomilled nanocrystalline aluminum containing diamantane nanoparticles  

British Library Electronic Table of Contents (United Kingdom)

The thermal stability of nanoscale grains in cryomilled aluminum powders containing 1% diamantane was investigated. Diamantane is a diamondoid molecule consisting of 14 carbon atoms in a diamond cubic structure that is terminated by hydrogen atoms. The nanostructures of the resulting cryomilled powders were characterized using both transmission electron microscopy (TEM) and X-ray diffraction (XRD) techniques. The average grain size was found to be on the order of 22?nm, a value similar to that obtained for cryomilled Al without diamantane. To determine thermal stability, the powders were heated in an inert gas atmosphere at constant temperatures between 423 and 773?K (0.51T m to 0.83T m) for exposure times of up to 10?h. The average grain size for all powders containing diamantane was obse...

2011-01-01

154

The deformation behavior of DyCu ductile intermetallic compound under compression  

British Library Electronic Table of Contents (United Kingdom)

In this study polycrystalline specimens of as-cast DyCu with B2 crystal structure were compressed to different strains at room temperature to test if stress-induced phase transformation and twinning occur during deformation. In these tests DyCu exhibited high ductility with plastic strain as high as 35% and ultimate compressive strength of ~790MPa. X-ray diffraction and transmission electron microscopy (TEM) showed no indications that DyCu had undergone stress-induced phase transformation or twinning. -type dislocations have been observed to play an important role for imparting the ductile behavior. TEM analyses showed the presence of second phases, Dy2O3 and DyCu2 within the DyCu. The mechanisms of ductility and impurity phase formation are discussed.

2011-01-01

155

Synthesis and characterization of undoped and TM (Co, Mn) doped ZnO nanoparticles  

British Library Electronic Table of Contents (United Kingdom)

Antibacterial activity of Transition metals (Mn, Co) doped ZnO nanopowders prepared by a DC thermal plasma method against Escherichia coli and Staphylococcus aureus are investigated. The phase and morphology studies have been carried out by X-ray diffraction, scanning electron microscopy (SEM) and transmission electron microscopy (TEM) respectively. All the samples of the present investigation are found to have hexagonal wurtzite structure and crystallite sizes are found to vary from 25nm to 30nm. Our bacteriological study showed the enhanced antibacterial activity of transition metals doped ZnO nanoparticles than undoped ZnO indicating the great potential of ZnO nanoparticles in relevant clinical and biomedical applications.

2011-01-01

156

Synthesis and characterization of in situ sodium-activated and organomodified bentonite clay/styrene-butadiene rubber nanocomposites by a latex blending technique  

British Library Electronic Table of Contents (United Kingdom)

In this article, we describe a method used to prepare an in situ sodium-activated, organomodified bentonite clay/styrene-butadiene rubber nanocomposite master batch via a latex blending technique. The clay master batch was used for compound formulation. Octadecyl amine was used as an organic intercalate. The clay was purchased from local suppliers and was very cheap. Sodium chloride was used for in situ activation of the clay. The wide-angle X-ray diffraction data indicated that the in situ sodium activation helped to increase the intergallery distance from 1.28 to 1.88 nm. A transmission electron micrograph indicated intercalation and partial exfoliation. The thermal properties were relatively better in the case of the sodium-activated, organomodified bentonite-clay-containing compound. A...

2009-01-01

157

Synthesis and characterization of Fe3O4Gg nanocomposites and their antibacterial performance  

British Library Electronic Table of Contents (United Kingdom)

We synthesized Fe3O4Gg nanocomposites through a combination of solvothermal, hydrothermal, and chemical redox reactions. Characterization of the resulting samples by X-ray diffraction, Fourier-transform infrared spectroscopy, field-emission scanning and transmission electron microscopy, and magnetic measurement is reported. Compared to Fe3O4g nanocomposites, the Fe3O4Gg nanocomposites showed enhanced antibacterial activity. The Fe3O4Gg nanocomposites were able to almost entirely prevent growth of Escherichia coli when the concentration of Ag nanoparticles was 10mg/mL. Antibacterial activity of the Fe3O4Gg nanocomposites was maintained for more than 40h at 37^oC. The intermediate carbon layer not only protects magnetic core, but also improves the dispersion and antibacterial activity of the...

2011-01-01

158

Surface changes on LiNi{sub 0.8}Co{sub 0.2}O{sub 2} particles during testing of high-power lithium-ion cells.  

Energy Technology Data Exchange (ETDEWEB)

LiNi{sub 0.8}Co{sub 0.2}O{sub 2} particles from high-power lithium-ion cells were examined to determine material changes that result from accelerated aging tests. X-ray absorption spectroscopy (XAS) and transmission electron microscope (TEM) data indicated a Li{sub x}Ni{sub 1-x}O-type layer on the particle surfaces. The greater thickness on particles from high-power fade cells indicate that these surface layers are a significant contributor to cathode impedance rise observed during cell tests.

2002-08-01

159

Study of the application of BATAN's equipment for nuclear forensic activities  

International Nuclear Information System (INIS)

Nuclear forensic activities, such as in illicit trafficking, can solve a problem who did it and can gain the basis for a response. Other than that, the forensics can be also applied to solve on what are materials, who is responsible, is there more, where was material diverted and what route did the material taken. BATAN, in fact , owns a lot of equipment which can be supported for nuclear forensics activities, such as, Transmission Electron Microscope (TEM), Scanning Electron Microscope (SEM) as well as X-Ray Diffraction (XRD). For the first step, BATAN has to be an active, participate member of The International Technical Working Group on Nuclear Smuggling (ITWG). BATAN can then collaborate not only with Indonesia Arm Forces and Police, but also with other foreign institutions to develop this activity with mutual advantages agreement.

2005-10-01

160

Structural and optical investigation of sputter deposited hydrophobic chromium oxynitride films  

British Library Electronic Table of Contents (United Kingdom)

Nanocrystalline chromium oxynitride films were deposited by reactive RF magnetron sputtering of metallic chromium target in argon and helium atmospheres. The paper deals with consequence of increase in oxygen partial pressure on structural, hydrophobic and optical properties of chromium oxynitride films. The film stoichiometry changes from CrN and Cr2O3 to only Cr2O3 with increase in oxygen partial pressure as evident from X-Ray Diffraction analysis in both cases. The average crystallite size decreases with increase in oxygen partial pressure for both gas atmospheres. The thickness calculated from transmission data and surface profilometer are in good harmony with each other. The deposited films are hydrophobic by nature and the contact angle of the films varies as a function of surface ro...

2011-01-01

161

Silver nanoparticles prepared by chemical reduction-protection method, and their application in electrically conductive silver nanopaste  

Energy Technology Data Exchange (ETDEWEB)

Ag nanoparticles were prepared in a water-phase system with a mixture of silver-ammonia complex, sodium borohydride, and lauric acid according to molar feed ratio of approximately 6:3:1. The mechanism of preparation and separation by chemical reduction-protection method was explored. The as-synthesized Ag nanoparticles were characterized by transmission electron microscopy (TEM), X-ray diffraction (XRD) and UV-vis spectroscopy, respectively. It was found that the size of high purity Ag particles was ranging from 30 to 50 nm with slight agglomeration. In addition, the as-synthesized wet Ag nanoparticles were dispersed stably in organic vehicle to formulate electrically conductive nanopaste. Upon direct-written and sintered, the array pattern of the nanopaste with the resolution of about 30 {mu}m was achieved with the electrical resistivity in the order of magnitude of 10{sup -5} {Omega} cm.

2010-04-02

162

Radiation protection - an overview of the concept for radiation protection at work and the concept for environmental radiation protection  

International Nuclear Information System (INIS)

This book gives an overview of the entire field of radiation protection with the subject areas radioactivity, X-rays, UV radiation, laser beams and high-frequency electromagnetic fields. It deals graphically with the most important physical notions, the incidence, origin, properties and biological effects of types of radiation, administrative and practical protection measures and the code of rules governing them. Apart from fundamentals of radiation protection the emphasis on the following: natural radiation exposure, radiation exposure to radon, disaster relief plans in the environment of nuclear plant, the precautionary radiation protection system evolved after Chernobyl, radiation exposure through UV radiation devices, radio, RF communication, radar, microwave ovens and high-voltage transmission lines as well as computer work-places. (orig.).

1993-01-01

163

Preparation and characterization of nano hydroxyapatite/polymeric composites materials. Part I  

British Library Electronic Table of Contents (United Kingdom)

The present study is focused on preparation of nano composite materials and the effect of citric acid on their different properties. The formation of nano HA and its interaction with chitosan (C), gelatin (G) polymers and citric acid (CA) materials were studied. The Fourier Transformed Infrared Spectroscopy (FT-IR), X-ray diffraction (XRD), thermo-gravimetric analysis (TGA), transmission electron microscope (TEM), and scanning electron microscope (SEM) were used to characterize these composite materials. The compressive strength (CS) was also measured to know the reinforcement of the prepared composites. The results show that carboxylic and amino groups play crucial role for HA formation on chitosan-gelatin polymeric matrix in the presence of citric acid (CA). The formation of nano HA part...

2011-01-01

164

Point-contact Andreev spectroscopy on thin Ni_2MnIn Heusler films  

International Nuclear Information System (INIS)

Heusler films with L2_1 and B2 structure are deposited simultaneously on amorphous carbon films, Si(100) surfaces, and in situ cleaved InAs(110) surfaces by coevaporation of Ni and the alloy MnIn. Morphology, structure, and stoichiometry are investigated with transmission-electron microscopy, electron diffraction, and X-ray spectroscopy. The almost perfect lattice match supports highly oriented growth of Ni_2MnIn on InAs, which is proven by electron diffraction under grazing incidence. The electrical resistivity of thin films on Si show metallic behavior. At temperatures of liquid helium point-contact Andreev reflection spectroscopy is performed on films grown on Si(100) and in situ cleaved InAs(110) surfaces yielding spin polarizations comparable to the ones of Fe, Ni, Co, and permalloy (Ni_8_0Fe_2_0).

2007-09-01

165

Phase formation sequence in the Pd-GaAs system  

Energy Technology Data Exchange (ETDEWEB)

The morphological aspects of ternary phase formation during the Pd-GaAs reaction have been studied by application of transmission electron microscopy (TEM) and Rutherford backscattering (RBS) techniques. The TEM images show that the first product phase, ''phase I'', forms during deposition of Pd onto (100) GaAs and exhibits the preferred orientation (0001)/sub I/ approx. // (01 anti 1)/sub GaAs/. In the presence of unreacted Pd, the second phase, ''phase II'', nucleates at large-angle grain boundaries in the phase I film as the annealing temperature increases above approx.250C. Energy dispersive analysis of x-rays and RBS suggest the nominal compositions Pd3GaAs and Pd4GaAs for phases I and II, respectively.

1985-12-01

166

On plasma nitriding of steels  

Energy Technology Data Exchange (ETDEWEB)

With the aim of optimizing the nitriding process, experimental studies of the plasma nitriding of four selected steels were carried out, using a d.c. glow discharge. The process parameters were varied systematically. By means of transmission and scanning electron microscopy and X-ray diffraction, the microstructures, including the thicknesses of the compound zones and the diffusion zones of the nitrided steels, were obtained. Using cross-sectional samples and a micro-Vickers indenter, hardness depth profiles were also obtained. From the time and temperature dependences of the hardness profiles, effective diffusion constants and corresponding activation enthalpies were obtained. Furthermore, in an attempt to shed some light on the atomistic nitriding mechanisms, the glow discharges were studied by measuring energy spectra of the energetic ions hitting the cathode (the steel test specimens). It was shown that an increase of the mean energy of the ...

2000-02-01

167

Morphology and properties of silane-modified montmorillonite clays and clay/PBT composites  

British Library Electronic Table of Contents (United Kingdom)

Commercially available organoclay (Closite 30B) was modified by using 3-aminopropyltriethoxysilane (APS) via a silylation reaction. Sodium clay (Closite Na) was treated by APS directly as a control. Such modified clays were further melt-compounded with polybutylene terephthalate (PBT). The morphology and properties of the modified organoclays were characterized with X-ray diffraction (XRD), transmission electrical microscopy (TEM), Infra-red spectroscopy, contact angle measurement, and thermogravimetric analysis (TGA). The effects of modified clays on the crystallization behavior of PBT were characterized by differential scanning calorimetry. The basal spacing of Closite Na was enlarged from 1.01 to 1.41 nm after APS treatment, indicating that the APS was intercalated into the clay interga...

2008-01-01

168

Microstructure and atomic effects on the electroluminescent efficiency of SrS:Ce thin film devices  

International Nuclear Information System (INIS)

Transmission electron microscopy and x-ray diffraction data show that rapid thermal anneals of SrS:Ce thin films enhance grain size and reduce crystalline defects. Electron paramagnetic resonance results suggest that these anneals lead to less variance in the crystal field environments at the nearly cubic Ce"3"+ sites along with the formation of another type of Ce"3"+ site believed to involve a nearby Sr vacancy. We suggest that the association of Ce"3"+ sites with V_S_r shifts the electroluminescence towards larger wavelengths as the symmetry of the activator site is lowered. copyright 1997 American Institute of Physics.

169

Microstructural characterization of plasma nitrided austenitic stainless steel  

Energy Technology Data Exchange (ETDEWEB)

The microstructure of the layers produced by plasma nitriding austenitic stainless steel at different treatment temperatures (400 and 500 C) were studied by transmission electron microscopy (TEM) together with X-ray diffraction (XRD) and scanning electron microscopy (SEM). The results show that the microstructures were composed of 'expanded austenite' ({gamma}{sub N}) and {alpha}(ferrite)+CrN following plasma nitriding at lower and higher treatment temperatures, respectively. The former contains stacking faults and deformed twin substructures, while the latter is made up of colonies displaying a lamellar structure. Kurdjumov-Sachs or Nishiyama-Wassermann orientation relationships between the {alpha} and CrN layer were observed. (orig.)

2000-10-23

170

Microstructural aspects of the corrosion of Alloy 800  

International Nuclear Information System (INIS)

Transmission electron microscopy studies on solution-annealed Alloy 800 revealed small (100-200 nm), spherical-shaped titanium carbide (face centered cubic structure) and large (200 nm-5 #mu#m), faceted titanium nitride (hexagonal structure) particles randomly distributed in the austenite matrix. The volume fraction of former particles was found to be greater than that of the latter. Corrosion studies of the alloy in acidic, chlorides and acidic chloride environments at room temperature indicated that the passivity of Alloy 800 was adversely affected by the addition Cl"- ions. X-ray photoelectron spectroscopy revealed that the surface film formed on the alloy at the onset of passivity consisted of Cr"3"+ (as Cr_2O_3), without any Fe"3"+/Fe"2"+ or Ni"2"+. Scanning electron microscopy studies indicated initiation of pitting at large, faceted particles, not at small, spherical-shaped ones.

2004-12-01

171

Manufacturing of oxide-dispersion-strengthened steels with the use of preliminary surface oxidation  

British Library Electronic Table of Contents (United Kingdom)

Regularities of deformation-induced dissolution of a surface layer of iron oxides in matrixes of iron-based alloys with bcc and fcc lattices have been studied by the methods of M?ssbauer spectroscopy, transmission electron microscopy, and X-ray diffraction. A method of producing iron alloys strengthened by dispersed oxide nanoparticles and alloyed with elements possessing a high affinity to oxygen (titanium and yttrium) has been proposed, which implies a dynamic dissolution of a surface layer of iron oxides upon strong cold deformation and a precipitation of secondary yttrium and titanium nanooxides upon a subsequent high-temperature sintering of mechanically alloyed powders. There has been demonstrated a possibility of oxide strengthening of pure iron upon its interaction with air without...

2011-01-01

172

Hydriding properties of a mechanically milled Mg-50 wt.% ZrFe{sub 1.4}Cr{sub 0.6} composite  

Energy Technology Data Exchange (ETDEWEB)

The ball-milling method was used to produce Mg-50 wt.% ZrFe{sub 1.4}Cr{sub 0.6} composite. The thermodynamic, kinetic, and cycling properties, as well as the resistance to oxidation were examined. This composite possesses excellent kinetic properties, even at moderate temperature. Scanning electron microscopy, energy-dispersive spectrum, transmission electron microscopy and X-ray diffraction were used to characterize the composite before and after hydriding. The fine ZrFe{sub 1.4}Cr{sub 0.6} particles covering Mg particles acting as a ''catalytic film'', a significant amount of imperfections and some alloy powder in the Mg matrix introduced by ball milling all contributed to the enhanced absorption/desorption rate. (orig.)

2000-02-02

173

High resolution electron microscopy study of as-prepared and annealed tungsten-carbon multilayers  

International Nuclear Information System (INIS)

A series of sputtered tungsten-carbon multilayer structures with periods ranging from 2 to 12 nm in the as-prepared state and after annealing at 500 degrees C for 4 hours has been studied with high resolution transmission electron microscopy. The evolution with annealing of the microstructure of these multilayers depends on their period.As-prepared structures appear predominantly amorphous from TEM imaging and diffraction. Annealing results in crystallization of the W-rich layers into WC in the larger period samples, and less complete or no crystallization in the smaller period samples. X-ray scattering reveals that annealing expands the period in a systematic way. The layers remain remarkably well-defined after annealing under these conditions.

174

Graphene-Pt nanocomposite for nonenzymatic detection of hydrogen peroxide with enhanced sensitivity  

British Library Electronic Table of Contents (United Kingdom)

A sensitive hydrogen peroxide (H2O2) sensor was fabricated based on graphene-Pt (GN-Pt) nanocomposite. The GN-Pt was synthesized by photochemical reduction of K2PtCl4 on GNs, and characterized by atomic force microscope (AFM), transmission electron microscope (TEM), and energy-dispersive X-ray spectroscopy (EDS). Electrochemical investigations indicated that the GN-Pt exhibited a high peak current and low overpotential towards the reduction of H2O2. The GN-Pt modified glass carbon electrode displayed a wide linear range (2-710mM), low limit of detection (0.5mM) and good selectivity for detection of H2O2 with a much higher sensitivity than that of Pt nanoparticles or graphene modified electrode.

2011-01-01

175

Electrochemical properties and growth mechanism of passive films on Alloy 690 in high-temperature alkaline environments  

Energy Technology Data Exchange (ETDEWEB)

Passive films formed on Alloy 690 in high-temperature alkaline environments were investigated by potentiodynamic polarization, X-ray photoelectron spectroscopy, transmission electron microscopy and Mott-Schottky approach. Passive current density and donor density of the passive films increase with increasing temperature, due to increased diffusion rates of metallic ions and dehydration of hydroxide phases. The passive films show a duplex structure including an inner layer of fine-grained Cr oxide or spinel oxide and an outer layer of Ni-Fe spinel oxide and Ni hydroxide. A growth model of the passive films on Alloy 690 in high-temperature alkaline environments is proposed and discussed.

2010-10-15

176

Electrochemical properties and growth mechanism of passive films on Alloy 690 in high-temperature alkaline environments  

International Nuclear Information System (INIS)

Passive films formed on Alloy 690 in high-temperature alkaline environments were investigated by potentiodynamic polarization, X-ray photoelectron spectroscopy, transmission electron microscopy and Mott-Schottky approach. Passive current density and donor density of the passive films increase with increasing temperature, due to increased diffusion rates of metallic ions and dehydration of hydroxide phases. The passive films show a duplex structure including an inner layer of fine-grained Cr oxide or spinel oxide and an outer layer of Ni-Fe spinel oxide and Ni hydroxide. A growth model of the passive films on Alloy 690 in high-temperature alkaline environments is proposed and discussed.

2010-10-01

177

Electrochemical deposition of indium sulfide thin films using two-step pulse biasing  

British Library Electronic Table of Contents (United Kingdom)

Indium sulfide thin films were deposited onto indium-tin-oxide coated glass substrate by electrochemical deposition from an aqueous solution containing In2 (SO4) 3 and Na2S2O3. The deposition conditions were optimized on the basis of data obtained by scanning electron microscope, Auger electron spectroscopy and optical transmission measurements. Furthermore, the photosensitivity of the films was observed by means of photoelectrochemical measurements, which confirmed that the indium sulfide showed n-type conduction. The X-ray diffraction and Raman studies revealed that the as-grown films were amorphous or nanocrystalline in nature and became polycrystalline In2S3 after annealing.

2008-01-01

178

Effect of treatment of Bis(3-triethoxysilyl propyl)tetrasulfane on physical property of in situ sodium activated and organomodified bentonite clay - SBR rubber nanocomposite  

British Library Electronic Table of Contents (United Kingdom)

This study describes the effect of treatment of Bis(3-triethoxysilyl propyl)tetrasulfane (silane coupling agent, Si69, TESPT) on in situ sodium activated, organo modified bentonite clay - styrene butadiene rubber (SBR) nanocomposite. transmission electron microscopy and Wide angle X-ray diffraction indicated the intercalation as well as partial exfoliation in both the organoclay and silane treated organoclay compound. It was found that about 5% of silane with respect to clay was the optimum dose for the treatment. Around 15% improvement in tensile and tear strength was observed due to silane treatment. Silane treated organoclay exhibited substantial improvement of the fatigue life, compression set, and rebound property. A detailed study of physical property was carried out. A comparison wi...

2010-01-01

179

Disordered bcc γ-phase to δ-phase transformation in Zr-rich U-Zr alloy  

British Library Electronic Table of Contents (United Kingdom)

The transformation mechanism of hexagonal delta phase from the disordered bcc gamma phase has not been reported before in the Zr-rich U-Zr alloy system. With the help of X-ray diffraction, transmission electron microscopy (TEM) and high-resolution TEM analyses it was shown that the gamma to delta conversion takes place by the lattice collapse mechanism of omega transformation. It was also ascertained that a higher aging temperature or time promotes the growth of all four variants of the delta phase within a parent gamma grain. In addition, ab initio electronic structure calculations showed that the bcc to hexagonal transformation, involving partial ordering of the parent bcc phase followed by (111) plane collapse, is energetically favorable.

2011-01-01

180

Diffuse X-ray scattering study of sublattice ordering among group III atoms in In_0_._5Ga_0_._5P and In_0_._5Al_0_._5P  

International Nuclear Information System (INIS)

The intensity of superstructure reflections and associated diffuse scattering from In_0_._5Ga_0_._5P and In_0_._5Al_0_._5P epitaxic layers grown on (001) GaAs substrates was mapped in reciprocal space. The Warren-Cowley short-range-order parameters were obtained through the usual process for evaluating Fourier coefficients. Varying values for the correlation length in different directions indicate how group III atoms stack up in ordered states. The resultant structure with long-range order confirms the hypothesis made on the basis of electron diffraction and high-resolution transmission electron microscopy studies. (orig.).

181

Bandgap properties of the indium sulfide thin-films grown by co-evaporation  

British Library Electronic Table of Contents (United Kingdom)

In the present study the optical properties of co-evaporated indium sulfide thin films are investigated. Before being optically characterized, the composition as well as the crystalline properties of the film have been checked with the help of energy dispersive spectroscopy (EDX) and X-Ray diffraction (XRD) analyses. The optical absorption coefficient ? of this indium sulfide film has been deduced from reflectivity R(?) and transmission T(?) measurements. The fit of the curve representing ?(h?) suggests that the ?-In2S3 has an indirect bandgap of 2.01?eV. Density functional theory (DFT) calculations are performed on this indium sulfide compound, using TB-LMTO code. Through these band structure investigations, an indirect bandgap is predicted as observed experimentally. The top of the valen...

2009-01-01

182

A novel graphene nanosheets coated stainless steel fiber for microwave assisted headspace solid phase microextraction of organochlorine pesticides in aqueous samples followed by gas chromatography with electron capture detection  

British Library Electronic Table of Contents (United Kingdom)

In this study, a novel graphene nanosheets (GNSs) coated solid phase microextraction (SPME) fiber was prepared by immobilizing microwave synthesized GNSs on a stainless steel wire. Microwave synthesized GNSs were verified by X-ray diffraction, field emission-scanning electron microscopy (FE-SEM) and transmission electron microscope (TEM). GNS-SPME fiber was characterized using FE-SEM and the results showed the GNS coating was homogeneous, porous, and highly adherent to the surface of the stainless steel fiber. The performance and feasibility of the GNS-SPME fiber was evaluated under one-step microwave assisted (MA) headspace (HS) SPME followed by gas chromatography with electron capture detection for five organochlorine pesticides (OCPs) in aqueous samples. Parameters influencing the extra...

2011-01-01

183

A micro-alloyed ferritic steel strengthened by nanoscale precipitates  

British Library Electronic Table of Contents (United Kingdom)

A ferritic steel with finely dispersed precipitates was investigated to reveal the fundamental strengthening mechanisms. The steel has a yield strength of 760MPa, approximately three times higher than that of conventional Ti-bearing high strength hot-rolled sheet steels, and its ultimate tensile strength reaches 850MPa with an elongation-to-failure value of 18%. Using energy dispersive X-ray spectroscopy (EDXS) and transmission electron microscope (TEM), fine carbides TiC with an average diameter of 10nm were observed in the ferrite matrix of the 0.08%Ti steel, and some cubic M23C6 precipitates were also observed at the grain boundaries and the interior of the grains. The finely dispersed TiC precipitates in the matrix provide matrix strengthening. The estimated magnitude of precipitation ...

2011-01-01

184

x - NASA Technical Reports Server  

Science.gov (United States)

Mar 1, 2011 ... Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation ...

186

NASA Technical Reports Server - Radionuclide X-ray fluorescence ...  

Science.gov (United States)

Aug 1, 1972 ... The principles of radionuclide excitation of X-ray fluorescence radiation and its application in analytic chemistry are discussed.

187

A comparison of the X-ray properties of X Per and gamma Cas  

Energy Technology Data Exchange (ETDEWEB)

The X-ray properties of the main sequence Be stars conclude that they are a widely separated binary system containing an accreting neutron star.

1982-04-01

188

Metrological applications of X-ray waveguide thin film structures in X-ray reflectometry and diffraction  

International Nuclear Information System (INIS)

The effect of resonance, observed in X-ray waveguide layered structures in a characteristic way influences the scattering properties of the films. It is well known that the resonant region in the reflectivity shows a series of minima, usually very deep and extremely narrow. The positions and depths of the minima depend only on X-ray waveguide and quasi X-ray waveguide film structural properties, on the X-ray wavelength and on the incident beam divergence. In the present work we propose and discuss the application of the X-ray waveguide and quasi X-ray waveguide film structures as a tools to experimental evaluation of some quantities related to X-ray reflectometric and diffractometric measurements, like the beam divergence, wavelength, or angular distance. Examples of application of X-ray waveguide as an excellent tool ...

2001-09-23

189

Molar extinction coefficients in aqueous solutions of some alkaline earth chlorides  

International Nuclear Information System (INIS)

Molar extinction coefficients for the solid solutes in aqueous solutions of some alkaline earth chlorides such as MgCl_2.6H_2O, CaCl_2, SrCl_2.6H_2O and BaCl_2.2H_2O have been determined at 81, 356, 511, 662, 1173 and 1332 keV energies in different concentration using the narrow beam transmission methods. (author)

1999-12-21

190

Metal contacts to n-GaN  

International Nuclear Information System (INIS)

Al, Au, Ti/Al and Ti/Au contacts were prepared on n-GaN and annealed up to 900 deg. C. The structure, phase and morphology were studied by cross-sectional transmission and scanning electron microscopy as well as by X-ray diffraction (XRD), the electrical behaviour by current-voltage measurements. It was obtained that annealing resulted in interdiffusion, lateral diffusion along the surface, alloying and bowling up of the metal layers. The current-voltage characteristics of as-deposited Al and Ti/Al contacts were linear, while the Au and Ti/Au contacts exhibited rectifying behaviour. Except the Ti/Au contact which became linear, the contacts degraded during heat treatment at 900 deg. C. The surface of Au and Ti/Au contacts annealed at 900 deg. C have shown fractal-like structures revealed by scanning electron microscopy. Transmission electron microscopy and XRD investigations of the Ti/Au contact revealed that Au diffused ...

2006-11-15

191

Valence electronic structure of Ti, Cr, Fe and Co in some alloys from K{beta}-to-K{alpha} X-ray intensity ratio studies  

Energy Technology Data Exchange (ETDEWEB)

K{beta}-to-K{alpha} X-ray intensity ratios of Ti, Cr, Fe and Co in pure metals and in Cr{sub 0.26}Fe{sub 0.74}, Cr{sub 0.80}Co{sub 0.20} and Ti{sub 0.80}Cr{sub 0.20} alloys have been measured following excitation by 59.54 keV {gamma}-rays from a 7400 MBq (200 mCi) {sup 241}Am point-source. The valence electronic structure of Ti, Cr, Fe and Co in the samples have been evaluated by the comparison of the measured K{beta}-to-K{alpha} intensity ratios with the results of multiconfiguration Dirac-Fock calculations performed for various electronic configurations of these metals. The 3d-electron populations obtained for pure metallic Ti, Cr, Fe and Co agree well with the results of band structure calculations of Papaconstantopoulos (Handbook of band structure of elemental solids, Plenum Press, New York, 1986). Our analysis indicates significant increase of 3d-electron population of Ti, Cr and Fe in the alloys with respect to the pure metals, except for ...

2002-10-01

192

Valence electronic structure of Ti, Cr, Fe and Co in some alloys from K#beta#-to-K#alpha# X-ray intensity ratio studies  

International Nuclear Information System (INIS)

K#beta#-to-K#alpha# X-ray intensity ratios of Ti, Cr, Fe and Co in pure metals and in Cr_0_._2_6Fe_0_._7_4, Cr_0_._8_0Co_0_._2_0 and Ti_0_._8_0Cr_0_._2_0 alloys have been measured following excitation by 59.54 keV #gamma#-rays from a 7400 MBq (200 mCi) "2"4"1Am point-source. The valence electronic structure of Ti, Cr, Fe and Co in the samples have been evaluated by the comparison of the measured K#beta#-to-K#alpha# intensity ratios with the results of multiconfiguration Dirac-Fock calculations performed for various electronic configurations of these metals. The 3d-electron populations obtained for pure metallic Ti, Cr, Fe and Co agree well with the results of band structure calculations of Papaconstantopoulos (Handbook of band structure of elemental solids, Plenum Press, New York, 1986). Our analysis indicates significant increase of 3d-electron population of Ti, Cr and Fe in the alloys with respect to the pure metals, except for Cr in ...

2002-10-01

193

K#beta#-to-K#alpha# x-ray intensity ratio studies of the valence electronic structure of Fe and Ni in Fe_xNi_1_-_x alloys  

International Nuclear Information System (INIS)

K#beta#-to-K#alpha# x-ray intensity ratios of Fe and Ni in pure metals and in Fe_xNi_1_-_x alloys (x=0.20, 0.50, 0.58) exhibiting similar crystalline structure have been measured following excitation by 59.54 keV #gamma# rays from a 200 mCi "2"4"1Am point source to understand why the properties of the Fe_xNi_1_-_x (x=0.2) alloy are distinct from other alloy compositions. The valence electronic structure of Fe and Ni in the samples has been evaluated by comparing the measured K#beta#-to-K#alpha# intensity ratios with the results of multiconfiguration Dirac-Fock calculations. Significant changes in the 3d electron population (with respect to the pure metal) are observed for Fe and Ni for certain alloy compositions. These changes can be explained by assuming rearrangement of electrons between 3d and (4s,4p) band states of the individual metal atoms. It has been found that the valence electronic structure of the Fe_0_._2Ni_0_._8 alloy is totally ...

2001-02-15

194

Synthesis of ?-Al2O3 nanowires through a boehmite precursor route  

British Library Electronic Table of Contents (United Kingdom)

Crystalline ?-Al2O3 nanowires with diameter, 20?40?nm, length above 600?nm and aspect ratio above 30 have been successfully synthesized by thermal decomposition of boehmite (?-AlOOH) precursors obtained via hydrothermal route by using AlCl3, NaOH and NH3 as starting materials. Thermogravimetric analysis (TG), differential thermal analysis (DTA), X-ray diffraction (XRD), transmission electron microscope (TEM), selected area electron diffraction (SAED) and high resolution transmission electron microscope (HRTEM) were used to characterize the features of the as-made ?-Al2O3 nanowires and their ?-AlOOH precursors. The pH value of the solution and the mixed precipitant play important roles in the formation of ?-AlOOH nanowires. After calcination at 500?C for 2?h, the orthorhombic ?-AlOOH transf...

2011-01-01

195

Scatter measurements for optical cone-beam computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Both x-ray and optical cone-beam CT (CBCT) scanners are limited by scattered photons that contaminate the primary images. Transparent radiochromic gels and plastics are anticipated to produce less scattering than polymerization gels and hence result in reconstructed dose distributions with greater contrast and dynamic range. Four methods of scatter measurement were investigated to quantify scatter fractions using an in-house optical CBCT scanner. The methods consisted of generating either 'coin' shadows or primary beamlets in transmission images. The four methods generated similar results of 10% scatter fractions in gel transmission images for this particular scanner configuration with both leuco crystal violet and carbon black micelle gels. The scatter contributions were distributed as 5% from micelle gel, 2% from Teflon wall, 2% from refractive index matching liquid and 1% other sources. Applying a ...

2009-05-01

196

Magnetic imaging of ion-irradiation patterned Co/Pt multilayers using complementary electron and photon probes  

Energy Technology Data Exchange (ETDEWEB)

The three-dimensional magnetic structure and reversal mechanism of patterned Co/Pt multilayers, were imaged using complementary Lorentz transmission electron microscopy (LTEM) (in-plane component) and magnetic transmission x-ray microscopy (M-TXM) (perpendicular magnetization). The Co/Pt films with perpendicular anisotropy were patterned by ion irradiation through a stencil mask to produce in-plane magnetization in the irradiated regions. The boundaries of the patterns, defined by the transition from out-of-plane to in-plane magnetization, were found to be determined by the stencil mask, whilst the scale of the magnetic reversal by the physical microstructure. The nucleation fields were substantially reduced to 50 Oe for the in-plane regions and 1 kOe for the perpendicular regions, comparing to 4.5 kOe for the as-grown film. The perpendicular reversals were found to always originate at the pattern boundaries.

2001-04-01

199

Stabilization of synchrotron radiation x-ray beam by MOSTAB  

International Nuclear Information System (INIS)

Monochromator stabilization (MOSTAB) is a feedback control system to stabilize an x-ray beam of synchrotron radiation. It applies a feedback voltage to a piezo electric transducer attached to a double-crystal monochromator. We developed MOSTAB modules and examined their performances using SPring-8 beamlines. The x-ray beam position stabilization using MOSTAB was realized simultaneously with the x-ray beam intensity stabilization. As an example of its application, we performed EXAFS measurement with MOSTAB. (author)

2003-05-01

200

Spin evolution in wind-fed X-ray binaries  

International Nuclear Information System (INIS)

Global angular momentum balance suggests that the neutron stars in Be/X-ray binaries are not spinning in equilibrium. This requires an X-ray lifetime ''approx <'' 10"5 yr, and suggests that there are many 'dead' Be/X-ray binaries in the Galaxy. Some of these may be turned up as millisecond radio pulsars with Be star companions. (author).

206

Radionuclide X-ray fluorescence analysis. 3: Examples of application in practice  

Science.gov (United States)

Examples are given of the applicability and importance of radionuclide fluorescence analysis as a

1973-01-01

207

Radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Slovak 1973. 164 p. Czechoslovakia Havranek, E. Bumbalova, A. Svitel,

1973-01-01

208

Possibilities of rayleigh-taylor instability measurement by X-ray phase imaging  

International Nuclear Information System (INIS)

X-ray imaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging

209

NONDESTRUCTIVE DETERMINATION OF AIRBORNE LEAD ...  

Science.gov (United States)

... NONDESTRUCTIVE DETERMINATION OF AIRBORNE LEAD PARTICULATES BY THE RADIONUCLIDE X-RAY FLUORESCENCE ANALYSIS. ...

211

Investigation of morphology and chemical composition of self-organized semiconductor quantum dots and wires by X-ray scattering  

International Nuclear Information System (INIS)

X-ray scattering methods suitable for the investigation of the morphology and chemical composition of self-organized quantum dots and quantum wires are reviewed. Their application is demonstrated in experimental examples showing that a combination of small angle X-ray scattering with high-resolution X-ray diffraction can reveal both the shape and the chemical composition of the self-organized objects. (author)

2001-09-23

212

Ectopic Ureter  

Science.gov (United States)

... such as renal flow scan or a formal kidney X-ray, called an intravenous pyelogram ( IVP ), may help ...

216

WITNESSING THE KEY EARLY PHASE OF QUASAR EVOLUTION: AN OBSCURED ACTIVE GALACTIC NUCLEUS PAIR IN THE INTERACTING GALAXY IRAS 20210+1121  

International Nuclear Information System (INIS)

We report the discovery of an active galactic nucleus (AGN) pair in the interacting galaxy system IRAS 20210+1121 at z = 0.056. An XMM-Newton observation reveals the presence of an obscured (N _H #approx# 5 x 10"2"3 cm"-"2), Seyfert-like (L _2_-_1_0_k_e_V = 4.7 x 10"4"2 erg s"-"1) nucleus in the northern galaxy, which lacks unambiguous optical AGN signatures. Our spectral analysis also provides strong evidence that the IR-luminous southern galaxy hosts a Type 2 quasar embedded in a bright starburst emission. In particular, the X-ray primary continuum from the nucleus appears totally depressed in the XMM-Newton band as expected in the case of a Compton-thick absorber, and only the emission produced by Compton scattering ('reflection') of the continuum from circumnuclear matter is seen. As such, IRAS 20210+1121 seems to provide an excellent opportunity to witness a key, early phase in the quasar evolution predicted by the theoretical models of ...

2010-10-20

217

High variability in Vela X-1: giant flares and off states  

CERN Document Server

We investigate the spectral and temporal behavior of the high mass X-ray binary Vela X-1 during a phase of high activity, with special focus on the observed giant flares and off states. INTEGRAL observed Vela X-1 in a long almost uninterrupted observation for two weeks in 2003 Nov/Dec. The data were analyzed with OSA 7.0 and FTOOLS 6.2. We derive the pulse period, light curves, spectra, hardness ratios, and hardness intensity diagrams, and study the eclipse. In addition to an already high activity level, Vela X-1 exhibited several intense flares, the brightest ones reaching a maximum intensity of more than 5 Crab in the 20-40 keV band and several off states where the source was no longer detected by INTEGRAL. We determine the pulse period to be 283.5320+/-0.0002 s, which is stable throughout the entire observation. Analyzing the eclipses provided an improvement in the ephemeris. Spectral analysis of the flares indicates that there appear to be ...

2008-01-01

218

Direct patterning of gold oxide thin films by focused ion-beam irradiation  

International Nuclear Information System (INIS)

For direct writing of electrically conducting connections and areas into insulating gold oxide thin films a scanning Ar"+ laser beam and a 30 keV Ga"+ focused ion beam (FIB) have been used. The gold oxide films are prepared by magnetron sputtering under argon/oxygen plasma. The patterning of larger areas (dimension 10-100 #mu#m) has been carried out with the laser beam by local heating of the selected area above the decomposition temperature of AuO_x(130-150 C). For smaller dimensions (100 nm to 10 #mu#m) the FIB irradiation could be used. With both complementary methods a reduction of the sheet resistance by 6-7 orders of magnitude has been achieved in the irradiated regions (e.g. with FIB irradiation from 1.5 x 10"7#OMEGA#/#square# to approximately 6 #OMEGA#/#square#). The energy-dispersive X-ray analysis (EDX) show a considerably reduced oxygen content in the irradiated areas, and scanning electron microscopy (SEM), as well as atomic force ...

2000-09-01

219

Correlation between ion beam parameters and physical characteristics of nanostructures fabricated by focused ion beam  

International Nuclear Information System (INIS)

We report a study of the physical characteristics of the pillars of C, Pt and W grown by 10-30 keV Ga focused ion beam (FIB) as a function of Ga ion flux, and present a quantitative analysis of the elements using energy-dispersive analysis of X-rays (EDAX). All the FIB grown pillars exhibit a rough morphology with whisker like protrusions on the cylindrical surface and broadening of the base as compared to the nominal size. For a constant fluence, the height of the pillar initially increases and then reduces after going through a maximum as a function of ion flux in all the cases. The compositional analysis shows good metallic quality for Pt structures but reveals significant contamination of Ga in C and Ga and C in W structures at higher ion fluxes. Explanation to all these observations has been sought in the light of secondary ion and electron effects and the different processes involved which lead to the FIB induced deposition.

2008-04-01

220

Are Optically-Selected Quasars Universally X-Ray Luminous? X-Ray/UV Relations in Sloan Digital Sky Survey Quasars  

CERN Document Server

We analyze archived Chandra and XMM-Newton X-ray observations of 536 Sloan Digital Sky Survey (SDSS) Data Release 5 (DR5) quasars (QSOs) at 1.7 <= z <= 2.7 in order to characterize the relative UV and X-ray spectral properties of QSOs that do not have broad UV absorption lines (BALs). We constrain the fraction of X-ray weak, non-BAL QSOs and find that such objects are rare; for example, sources underluminous by a factor of 10 comprise $\\la$2% of optically-selected SDSS QSOs. X-ray luminosities vary with respect to UV emission by a factor of $\\la$2 over several years for most sources. UV continuum reddening and the presence of narrow-line absorbing systems are not strongly associated with X-ray weakness in our sample. X-ray brightness is significantly correlated with UV emission line properties, so that relatively X-ray weak, non-BAL ...

2008-01-01

221

Radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The author's achievements in the title field are summarized and discussed. The following topics are dealt with: (i) principles of radionuclide X-ray fluorescence analysis; (ii) mathematical methods in X-ray fluorescence analysis; (iii) Ross differential filters; (iv) application of radionuclide X-ray fluorescence analysis in the coal industry (with emphasis on the determination of the ash content, sulfur content, and arsenic content of coal); and (v) evaluation of the X-ray fluorescence analyzer from the radiological safety point of view. (P.A.).

1994-01-01

222

Future of X-ray phase imaging in medical imaging technology  

International Nuclear Information System (INIS)

Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)

2007-04-01

223

Determination of ash content in coal by means of backscattered X-ray radiation and X-ray fluorescence analysis, and devices manufactured by the PAR company  

Energy Technology Data Exchange (ETDEWEB)

Discusses methods for determining ash content in coal using backscattering in X-ray fluorescence. The following aspects are evaluated: principle of ash content determination, energy sources, factors that influence measurement accuracy, reliability. Types of X-ray fluorescence analyzers developed in Czechoslovakia and manufactured in the Czech Republic are comparatively evaluated. Operation of the RPM 113.1 radionuclide X-ray fluorescence analyzer developed by the PAR company and used for measuring ash content in coal and coal calorific value is discussed. 7 refs.

1993-09-01

224

The study of the ion beam induced swelling in crystalline germanium irradiated by a 30 keV Ga"+ focused ion beam  

International Nuclear Information System (INIS)

The effect of swelling of crystalline Ge irradiated at room temperature with 30 keV Ga"+ focused ion beam (FIB) was studied by means of in situ FIB imaging, atomic force microscopy (AFM) and transmission electron microscopy (TEM). The swelling occurred in the surface region of amorphous damage layer which was formed during ion irradiation. The degree of swelling reaches values up to 10 times for an implantation dose of #approx#10"1"7 ions/cm"2. Cross-secitonal TEM examination showed that the swelling is due to formation of a porous layer with a honeycomb structure. (author). 8 refs., 4 figs.

2005-11-20

225

Biogenic iron oxyhydroxide formation at mid-ocean ridge hydrothermal vents: Juan de Fuca Ridge  

Energy Technology Data Exchange (ETDEWEB)

Here we examine Fe speciation within Fe-encrusted biofilms formed during 2-month seafloor incubations of sulfide mineral assemblages at the Main Endeavor Segment of the Juan de Fuca Ridge. The biofilms were distributed heterogeneously across the surface of the incubated sulfide and composed primarily of particles with a twisted stalk morphology resembling those produced by some aerobic Fe-oxidizing microorganisms. Our objectives were to determine the form of biofilm-associated Fe, and identify the sulfide minerals associated with microbial growth. We used micro-focused synchrotron-radiation X-ray fluorescence mapping (mu XRF), X-ray absorption spectroscopy (mu EXAFS), and X-ray diffraction (mu XRD) in conjunction with focused ion beam (FIB) sectioning, and highresolution transmission electron microscopy (HRTEM). The chemical and mineralogical composition of an Fe-encrusted biofilm was queried at ...

2008-05-22

226

X-ray phase imaging using a X-ray tube with a small focal spot. Improvement of image quality in mammography  

International Nuclear Information System (INIS)

Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a ...

2002-03-01

227

Temperature evolution of the internal magnetic hyperfine field of Metglas: amorphous and crystallized phases  

International Nuclear Information System (INIS)

We present differential scanning calorimetry (DSC), X-ray diffractometry, in situ Moessbauer spectroscopy (MS), and transmission electron microscopy (TEM) studies in Metglas ribbons subjected to different heat treatments. The temperature evolution of the hyperfine field H_h_f(T) and the Curie temperature (T_c) of the amorphous phase are determined. The magnetic field originally present in the amorphous phase has a 'normal' behavior, in the sense that it can be described by the Weiss molecular field theory. The total angular momentum of the iron atoms turns out to be 5/2 and this implies Fe"3"+ in which the electronic spins are uncoupled. When the samples are maintained near T_c (#approx#673 K), three new magnetic phases are detected in the Moessbauer spectra, indicating an onset of a crystallization process well below the first crystallization temperature (T_X_1), as determined by DSC (#approx#820 K). The magnetic behavior of these phases is ...

2000-11-01

228

Surfactant based sol-gel approach to nanostructured LiFePO{sub 4} for high rate Li-ion batteries  

Energy Technology Data Exchange (ETDEWEB)

Porous nanostructured LiFePO{sub 4} powder with a narrow particle size distribution (100-300nm) for high rate lithium-ion battery cathode application was obtained using an ethanol based sol-gel route employing lauric acid as a surfactant. The synthesized LiFePO{sub 4} powders comprised of agglomerates of crystallites <65nm in diameter exhibiting a specific surface area ranging from 8m{sup 2}g{sup -1} to 36m{sup 2}g{sup -1} depending on the absence or presence of the surfactant. The LiFePO{sub 4} obtained using lauric acid resulted in a specific capacity of 123mAhg{sup -1} and 157mAhg{sup -1} at discharge rates of 10C and 1C with less than 0.08% fade per cycle, respectively. Structural and microstructural characterization were performed using X-ray diffraction (XRD), scanning electron microscopy (SEM) and high-resolution transmission electron microscopy (HRTEM) with energy dispersive X-ray (EDX) analysis while ...

2007-01-01

229

Morphological and thermal properties of {beta}-SnS{sub 2} sprayed thin films using Boubaker polynomials expansion  

Energy Technology Data Exchange (ETDEWEB)

In this work, {beta}-SnS{sub 2} thin films have been prepared on glass substrates by the spray pyrolysis technique using an alcohol solution which contains tin chloride (SnCl{sub 4}) and thiourea (SC(NH{sub 2}){sub 2}) as precursors. The structural study shows that {beta}-SnS{sub 2} thin film prepared using optimal experimental conditions: substrate temperature T{sub s} = 280 deg. C and the concentration ratio of sulfur and tin elements in the spray solution x = [S]/[Sn] = 2.5, crystallizes in the hexagonal phase with a strong (0 0 1) X-ray diffraction line. In the same way, microprobe analyses (EPMA) as well as X-ray photoelectron spectroscopy (XPS) show the presence of undiserable phase of SnO{sub 2}. From the transmission and reflectance spectra, the band gap energy is 2.65 eV. On the other hand, the photothermal properties of such films have been studied, the thermal conductivity was K{sub c} = 0.85 W m{sup -1} K{sup ...

2009-05-27

230

Morphological and thermal properties of ?-SnS2 sprayed thin films using Boubaker polynomials expansion  

International Nuclear Information System (INIS)

In this work, ?-SnS2 thin films have been prepared on glass substrates by the spray pyrolysis technique using an alcohol solution which contains tin chloride (SnCl4) and thiourea (SC(NH2)2) as precursors. The structural study shows that ?-SnS2 thin film prepared using optimal experimental conditions: substrate temperature Ts = 280 deg. C and the concentration ratio of sulfur and tin elements in the spray solution x = [S]/[Sn] = 2.5, crystallizes in the hexagonal phase with a strong (0 0 1) X-ray diffraction line. In the same way, microprobe analyses (EPMA) as well as X-ray photoelectron spectroscopy (XPS) show the presence of undiserable phase of SnO2. From the transmission and reflectance spectra, the band gap energy is 2.65 eV. On the other hand, the photothermal properties of such films have been studied, the thermal conductivity was Kc = 0.85 W m-1 K-1 and the thermal diffusivity was Dc = 14.5 x 10-6 m2 s-1. The ...

2009-05-27

231

Development of PtRu-CeO{sub 2}/C anode electrocatalyst for direct methanol fuel cells  

Energy Technology Data Exchange (ETDEWEB)

Ceria (CeO{sub 2})-modified PtRu/C catalysts with different compositions of Ru and CeO{sub 2}, viz. PtRu{sub 0.9}(CeO{sub 2}){sub 0.1}/C, PtRu{sub 0.7}(CeO{sub 2}){sub 0.3}/C and PtRu{sub 0.5}(CeO{sub 2}){sub 0.5}/C and unmodified PtRu/C catalyst were synthesized by the sodium borohydride reduction method. Transmission electron microscopic results indicated that the lower concentrated CeO{sub 2}-modified PtRu/C catalysts had almost a similar morphological structure (well-dispersed particles with size around 2.3-2.5nm) with that of the unmodified PtRu/C catalyst. X-ray diffraction and X-ray photoelectron spectroscopy analyses indicated the formation of PtRu alloy and presence of CeO{sub 2} in an amorphous form with a mixed oxidation states (Ce{sup 3+}-Ce{sup 4+}). Electro-catalytic activity of these catalysts for methanol oxidation was investigated by linear sweep voltammetry and chronoamperometry and it was found that the ...

2006-06-01

232

An investigation of the origin of the electrochemical hydrogen storage capacities of the ball-milled Co-Si composites  

Energy Technology Data Exchange (ETDEWEB)

The Co-Si composites with a molar ratio of 2:1 are synthesized by ball-milling method and their potential as negative electrode materials of Ni-MH batteries is investigated. The microstructure, morphology and chemical state of the ball-milled Co-Si composites are characterized by X-ray diffraction (XRD), transmission electron microscopy (TEM) and X-ray photoelectron spectroscopy (XPS). XRD patterns show that the ball-milled samples for 10 and 20 h contain Co, Si and Co{sub 2}Si phases, and the ball-milled samples for 40 and 60 h are mainly amorphous Co{sub 2}Si alloys. In contrast to the high initial discharge capacity (1012 mAh/g) obtained for the sample ball-milled for 10 h, the discharge capacities of the samples ball-milled for 40 and 60 h are very low. It indicates that the hydrogen storage capacity of pure Co{sub 2}Si alloy is very low. It is found that the formation of active Co nanoparticles and Si oxidation are ...

2010-02-15

233

A simple template-free approach to TiO2 hollow spheres with enhanced photocatalytic activity.  

Science.gov (United States)

Mesporous anatase-phase TiO(2) hollow spheres with high photocatalytic activity were prepared by hydrothermal treatment and self-transformation of amorphous TiO(2) solid spheres in an NH(4)F aqueous solution. The prepared samples were characterized by X-ray diffraction, scanning and transmission electron microscopy, X-ray photoelectron spectroscopy, N(2) adsorption-desorption isotherms and UV-vis absorption spectroscopy. The photocatalytic activity was evaluated by photocatalytic oxidation decomposition of acetone in air under UV irradiation. It is found that F(-) plays an essential role in the formation of TiO(2) hollow spheres. F(-) not only induces the hollowing of TiO(2) solid spheres, but also promotes the crystallization of anatase TiO(2) nanocrystals. A possible formation mechanism for the TiO(2) hollow spheres by localized Ostwald ripening or chemically induced self-transformation is proposed based on the ...

2010-05-27

234

A novel method to characterize the MTF in 3D for computed mammotomography  

Science.gov (United States)

A novel phantom has been developed to measure the modulation transfer function (MTF) in 3D for x-ray computed tomography. The phantom consists of three tungsten wires, positioned nearly orthogonal to each other. Simultaneous measurements of the MTF are taken at various locations along the three orthogonal reconstructed planes. Our computed mammotomography (CmT) system uses a Varian Paxscan 2520 digital x-ray detector which can be positioned anywhere in ~2pi steradian band and can have arbitrary trajectories. With a half-cone beam geometry and with the phantom positioned near the center of rotation, projection images are acquired over 360 degrees. Various 3D orbits are evaluated including vertical axis of rotation and saddle. Reconstructions were performed using an iterative ordered-subsets transmission algorithm on rebinned projection images, using various numbers of iterations. Rotation of reconstructed slices isolated ...

2006-03-01

235

Determination of radiation exposure and significance of its influential factors for X-rayed children in the GDR  

International Nuclear Information System (INIS)

After having discussed the peculiarities of children in X-ray diagnosis the application of the effective as well as the mean equivalent doses as to the determination of the radiation exposure in children is represented. In using computerized tomograms to determine position and extent of an organ the exposure by repeated X-raying was calculated referring to the entrance dose. Entrance dose measurements for all types of X-ray examination in hospitals and ascertainments of the frequency of radiograms in 20 X-ray departments were used to determine per capita and collective doses, resp., in several age groups. Alltogether, the per capita dose of children in the GDR amounts to 30% of that of adults. Conclusions were drawn as to taking measures to further reduction of radiation exposure: (1) Technical measures, such as positioning of patients, shielding of organs, quality assurance; (2) elaboration of ...

1988-01-01

236

A comparison of patient doses in lumbar spine radiography from various X-ray units in Poland  

Energy Technology Data Exchange (ETDEWEB)

A number of diagnostic X-ray units in Poland were subjected to analysis. The air kerma on X-ray tables was measured for the X-ray parameters used routinely during lumbo-sacral spine radiography of standard adult patient. Measurements of air kerma were performed using TLD made of lithium-fluoride. The doses received by patients in different X-ray departments can differ more than two orders of magnitude (from 0.42 mGy up to 72.11 mGy), for the same X-ray examination. The dose can be significantly reduced if fluorescent screens made from components of rare earth are used. (author). 10 refs, 1 fig., 2 tabs.

1995-12-31

237

Measurement of liquid nitrogen level by radiation  

Energy Technology Data Exchange (ETDEWEB)

The measurement of level in the liquid nitrogen vessel has been carried out by the weight conversion method using weigher or by putting directly a stick in the vessel. On a large CE tank, the pressure difference was read by manometer. These methods can not be used when the vessel does not put on the weigher or the pipe for manometer is stopped. We noticed the interaction between radiation ({gamma}-ray) and substance and applied it to determine the liquid nitrogen level. The results proved it the easy method for measurement of the level in the large CE tank. Cesium 137 ({gamma}-ray energy: 662 keV) was used as the radiation source. {gamma}-ray transmission dose was determined by GM survey meter. The liquid nitrogen level could be determined by using the change of the transmission dose with amount of liquid nitrogen. (S.Y.)

1995-07-01

238

Synthesis and electrochemistry properties of Sn-Sb ultrafine particles as anode of lithium-ion batteries  

International Nuclear Information System (INIS)

Ultrafine particles of Sn-Sb alloys with different chemical composition have been prepared by hydrogen plasma-metal reaction. Structure, morphology, size and chemical composition of the Sn-Sb ultrafine particles were investigated by transmission electron microscopy, X-ray diffraction, BET gas adsorption, and induction-coupled plasma spectroscopy. It was found that all the particles have spherical shapes, with average particle size in the range of 100-300 nm. The electrochemistry properties as an alternative anode material for lithium-ion batteries have been characterized by constant current cycling and cyclic voltammetry. Electrochemical measurements showed that the alloys with Sn-46.5 at.% Sb have best reversible capacity and capacity retention. It exhibited a high reversible lithium-ion storage capacity of 701 mAh g"-"1 in the initial cycle, which has remained at 81% (i.e., 566 mAh g"-"1) of its original capacity after 20 cycles.

2007-07-31

239

Synthesis and characterization of MoO_3 nanostructures by solution combustion method employing morphology and size control  

International Nuclear Information System (INIS)

Molybdenum oxide nanostructures were synthesized utilizing the solution combustion method where the ammonium molybdate powder and an organic additive were used as precursors. Different organic additives including ethylene diamine tetra-acetic acid (EDTA), polyethylene glycol 200 (PEG 200), sorbitol and urea were used as surfactants in order to investigate the effect of additive structure on morphology and particle size of products. Also various reaction parameters such as the additive/Mo molar ratio, concentration of metal ion in solution, pH of the reaction, and temperature of the synthesis media were changed to study effects on product morphology and size. Outcomes were characterized by Scanning Electron Microscopy (SEM), X-ray diffraction, and Transmission Electron Microscopy (TEM) techniques. Results show a variety of MoO_3 nanoparticles and nanorods produced within the size range of 10-80 nm. Furthermore, microrods and microsheets were ...

2010-05-01

240

Study of porous silicon morphologies for electron transport  

International Nuclear Information System (INIS)

Field emitter devices are being developed for the gigatron, a high-efficiency, high frequency and high power microwave source. One approach being investigated is porous silicon, where a dense matrix of nanoscopic pores are galvanically etched into a silicon surface. In the present paper pore morphologies were used to characterize these materials. Using of Scanning Electron Microscope (SEM) and Transmission Electron Microscope (TEM) images of both N-type and P-type porous layers, it is found that pores propagate along the <100> crystallographic direction, perpendicular to the surface of (100) silicon. Distinct morphologies were observed systematically near the surface, in the main bulk and near the bottom of N-type (100) silicon lift-off samples. It is seen that the pores are not cylindrical but exhibit more or less approximately square cross sections. X-ray diffraction spectra and electron diffraction patterns verified that bulk porous ...

1993-05-17

241

Silver nanoparticle-decorated carbon nanotubes as bifunctional gas-diffusion electrodes for zinc-air batteries  

Energy Technology Data Exchange (ETDEWEB)

Thin, lightweight, and flexible gas-diffusion electrodes (GDEs) based on freestanding entangled networks of single-walled carbon nanotubes (SWNTs) decorated with Ag nanoparticles (AgNPs) are tested as the air-breathing cathode in a zinc-air battery. The SWNT networks provide a highly porous surface for active oxygen absorption and diffusion. The high conductivity of SWNTs coupled with the catalytic activity of AgNPs for oxygen reduction leads to an improvement in the performance of the zinc-air cell. By modulating the pH value and the reaction time, different sizes of AgNPs are decorated uniformly on the SWNTs, as revealed by transmission electron microscopy and powder X-ray diffraction. AgNPs with sizes of 3-5 nm double the capacity and specific energy of a zinc-air battery as compared with bare SWNTs. The simplified, lightweight architecture shows significant advantages over conventional carbon-based GDEs in terms of weight, thickness and ...

2010-07-01

242

Radiation hardening of final optics for an ICF reactor  

International Nuclear Information System (INIS)

Radiation damage of the final optical components in an Inertial Confinement Fusion (ICF) reactor is a crucial issue for development of a laser-fusion reactor. To some extent, this problem will be encountered in the National Ignition Facility (NIF), but there, the integrated radiation dose will be considerably less than that encountered in a future reactor. This extremely harsh radiation environment necessitates shielding the ICF optics from direct neutron and x-ray bombardment. Several approaches have been suggested, such as the use of grazing incidence metal mirrors or fused silica wedge deflectors. While metal mirrors can withstand a larger radiation dose, their focusing qualities pose problems. Therefore wedge deflectors, originally suggested by Lawrence Livermore National Laboratory (LLNL) staff, represent a promising alternative. Radiation hardening of the fused silica deflectors using a new combined thermal/optical annealing approach is examined here as a ...

1995-04-24

243

Properties of ZnO thin films prepared by radio-frequency plasma beam assisted laser ablation  

International Nuclear Information System (INIS)

Zinc oxide thin films were obtained by laser ablation of a Zn target in oxygen reactive atmosphere, the oxygen being supplied either by a standard gas inlet valve or from a radio-frequency (rf) oxygen plasma. Pt-coated silicon and MgO were used as substrates. The influence of the deposition parameters as laser wavelength (266, 355, 1064 nm), laser fluence (1.5-20 J/cm2) and oxygen pressure (1-60 Pa) was studied. The influence of the rf plasma beam addition on the morphological proprieties of zinc oxide films was particularly investigated, simultaneously with several configurations of the direction of the ablation plasma, the rf plasma beam and the substrate. The obtained films, with thicknesses in the range of 50 nm to 1 ?m have been characterized by atomic force microscopy (AFM), X-ray diffraction (XRD), transmission electron microscopy (TEM).

2005-07-15

244

Preparation of ZnO varistors by solution nano-coating technique  

Energy Technology Data Exchange (ETDEWEB)

This paper introduces a new method to produce nano-composite powder for the preparation of high performance ZnO varistors. ZnO particles were coated with Bi{sub 2}O{sub 3}, Sb{sub 2}O{sub 3}, Co{sub 2}O{sub 3}, Cr{sub 2}O{sub 3} and other additives via liquid nano-coating technique. Then the prepared powder was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), thermal gravity and differential scanning calorimetry (TG-DSC) and particle size distribution. The results showed that the ZnO composite powder is homogeneously coated and ultrafine. The densification, phase composition and microstructure of ZnO varistors was studied by linear shrinkage, X-ray diffraction (XRD) and SEM, respectively. The preliminary electrical parameters of ZnO varistors showed that the breakdown voltage V {sub b} (1 mA/cm{sup 2}) and nonlinear coefficient {alpha} is 5400 V/cm and 50, respectively, much higher than that of ...

2006-06-15

245

Preparation of CaWO{sub 4}:Ln{sup 3+} SiO{sub 2} (Ln=Tb, Dy and Ho) nanoparticles by a combustion reaction and their optical properties  

Energy Technology Data Exchange (ETDEWEB)

The CaWO{sub 4}:Ln{sup 3+} SiO{sub 2} (Ln=Tb, Dy and Ho) nanoparticles were synthesized via a combustion process at 800 {sup o}C, using citric acid as chelating agent and fuel, ammonium nitrate as fuel, boric acid as flux material and silica as supports. The persistent phosphor nanoparticles were characterized by X-ray diffraction (XRD), reflectance UV-vis and fluorescence spectroscopy (PL) and transmission electron microscopy (TEM) techniques. XRD patterns indicated that crystalline calcium tungstate with scheelite structure was produced. The reflectance UV-vis spectra showed the broad absorption band of WO{sub 4}{sup 2-} groups and the PL spectra showed the WO{sub 4}{sup 2-} wide excitation band, broad emission band of WO{sub 4}{sup 2-} and characteristic emissions of Ln{sup 3+} ions. The average particle sizes were determined by TEM, which are about 50 nm.

2010-11-15

246

Preparation of CaWO_4:Ln"3"+ SiO_2 (Ln=Tb, Dy and Ho) nanoparticles by a combustion reaction and their optical properties  

International Nuclear Information System (INIS)

The CaWO_4:Ln"3"+ SiO_2 (Ln=Tb, Dy and Ho) nanoparticles were synthesized via a combustion process at 800 "oC, using citric acid as chelating agent and fuel, ammonium nitrate as fuel, boric acid as flux material and silica as supports. The persistent phosphor nanoparticles were characterized by X-ray diffraction (XRD), reflectance UV-vis and fluorescence spectroscopy (PL) and transmission electron microscopy (TEM) techniques. XRD patterns indicated that crystalline calcium tungstate with scheelite structure was produced. The reflectance UV-vis spectra showed the broad absorption band of WO_4"2"- groups and the PL spectra showed the WO_4"2"- wide excitation band, broad emission band of WO_4"2"- and characteristic emissions of Ln"3"+ ions. The average particle sizes were determined by TEM, which are about 50 nm.

2010-11-01

247

Optical and structural properties of Ge films from ion-assisted deposition  

International Nuclear Information System (INIS)

The optical properties and microstructure of germanium (Ge) films, prepared by ion-assisted deposition (IAD) process, were investigated. The Ge films were deposited on sapphire and silicon substrates, with and without simultaneous Ar+ bombardment. Higher index films, with a refractive index 7.7% larger than that of the single crystalline Ge wafer, were obtained with the IAD process. The density of the IAD film could be 1.5% greater than that of the e-beam film. The results of the heat treatment indicated that the optical and structural properties of the IAD films were more stable. Ge nano-crystallites could be observed under high ion power density, which induced a crystalline structure in the Ge thin films. The average size of the nano-crystallites, as determined from both the X-ray diffraction data and the transmission electron microscopy images, showed that no systematic change had occurred. The results presented in this work suggest that the ...

2008-11-28

248

On the evolution of quasicrystalline and crystalline phases in rapidly quenched Al-Co-Cu-Ni alloy  

International Nuclear Information System (INIS)

The occurrence of stable decagonal quasicrystalline phase in Al-Co-Ni and Al-Cu-Co alloys through conventional solidification is well established. Earlier, we have studied the effect of Cu substitution in place of Co in the Al_7_0Co_1_5Ni_1_5 alloy. Here we report the structural/micro-structural changes with substitution of Cu for Ni in rapidly solidified Al-Co-Ni alloys. The melt spun ribbons have been characterized using X-ray diffractometry, scanning and transmission electron microscopy. With an increase in Cu content in the melt spun Al_7_0Co_1_5Cu _xNi_1_5_-_x (x = 0-15 at.%) alloys, the relative amount of the decagonal phase decreased up to 10 at.% of Cu. At this composition, the quaternary alloy showed the co-existence of decagonal quasicrystal and superstructure of #tau#_3 vacancy ordered crystalline phases. The decagonal phase containing Cu showed more disordering than Al-Co-Ni alloys. The implication of the structural and ...

2007-03-25

249

Non-isothermal oxidation of ceramic nanocomposites using the example of Ti-Si-C-N powder: Kinetic analysis method  

Energy Technology Data Exchange (ETDEWEB)

A method of kinetic analysis applicable to non-isothermal oxidation processes of ceramic nanocomposites is presented using Ti-Si-C-N powder as the substrate. The nanoparticle size and phase composition were determined using high-resolution transmission electron microscopy and X-ray diffraction (XRD). Thermogravimetric measurements were carried out for powder samples in dry air in the temperature range 298-1770 K. The following heating rates were applied: 3, 5, 10, 20 K min{sup -1}. Mass spectrometry was used to analyze gaseous oxidation products and solid products were identified by the XRD technique. The Coats-Redfern equation was applied for the kinetic analysis. For each stage of the oxidation kinetic models, the best accuracy was achieved using a series of criteria, and then the A and E parameters of the Arrhenius equations were estimated. Both linear regression and artificial neural networks were applied in testing kinetic models.

2008-08-15

250

Ni, Pd, and Pt on GaAs: A comparative study of interfacial structures, compositions, and reacted film morphologies  

Energy Technology Data Exchange (ETDEWEB)

The reactions between (100) GaAs and the near-noble metals Ni, Pd, and Pt have been investigated by application of high-resolution transmission electron microscopy (TEM), energy-dispersive analysis of x rays in the scanning TEM and Rutherford backscattering spectrometry. Emphasis is placed on the evolution of the phase distributions, film compositions, and interface morphologies during annealing at temperatures up to 480 /sup 0/C. The first phase in the Ni/GaAs reaction is shown to have the nominal composition Ni/sub 3/GaAs. Ternary phases of the type Pd/sub x/GaAs are also found to be the dominant products of the Pd/GaAs reaction. Conversely, only binary phases result from the Pt/GaAs reaction. These observations are used to construct isothermal sections of the M--Ga--As thin-film phase diagrams. The behavior of a thin (1--2 nm) native oxide--hydrocarbon layer during the Ni/GaAs, Pd/GaAs, and Pt/GaAs reactions is also ...

1987-03-01

251

Nanocrystallization of soft magnetic Fe-Co-Zr-Cu-B alloys  

International Nuclear Information System (INIS)

In the present study, Fe_4_1Co_4_1 B_1_0Zr_7Cu_1 alloy has been investigated in order to evaluate its thermal stability and structure after heat treatment, as well as the impact of heat treatment on magnetic properties. X-ray diffractometry, differential scanning calorimetry, chemical composition microanalysis, transmission electron microscopy, and magnetic hysteresis loop measurement techniques were employed. The crystallization temperature of the as-quenched alloy is 490"oC (continuous heating at 5 "oC/min). The melt spun ribbon having 27 #mu#m in thickness was annealed for 1 hour at temperatures from 400 to 700 "oC. The alloy after treatment at about 550"oC underwent primary crystallization, with the average size of crystals under 20 nm. This specimen shows the coercive field of 38 A/m, as compared to about 160 A/m reported for a similar alloy (Fe_4_4Co_4_4B_4Zr_7Cu_1) with a similar structure, annealed at 600"oC. (author)

2001-09-23

252

Microstructural evaluation of as-solidified and heat-treated [gamma]-TiAl based powders  

Energy Technology Data Exchange (ETDEWEB)

Powders with nominal compositions (in atomic percent) Ti-48Al and Ti-48Al-2Nb-2Cr were prepared by the plasma rotating electrode process (PREP) and gas atomization (GA) techniques. As-solidified and heat-treated (1000degC per 3 h) powder samples were examined by metallography, scanning electron microscopy, X-ray diffraction and transmission electron microscopy. The microstructures of the powders were characterized as a function of atomization technique, alloy content, powder particle size (solidification rate) and thermal history. All of the as-solidified powders were comprised of disordered [alpha], and ordered [alpha][sub 2]-Ti[sub 3]Al and [gamma]-TiAl. For both alloys, a larger volume fraction of [alpha] and [alpha][sub 2] was observed in the PREP powders relative to GA powders of comparable size. Additionally, for both alloys and both atomization techniques, the volume fraction of [alpha][sub 2] was observed to increase with decreasing ...

1992-05-15

253

Microstructural aspects of the corrosion of Alloy 800  

Energy Technology Data Exchange (ETDEWEB)

Transmission electron microscopy studies on solution-annealed Alloy 800 revealed small (100-200 nm), spherical-shaped titanium carbide (face centered cubic structure) and large (200 nm-5 {mu}m), faceted titanium nitride (hexagonal structure) particles randomly distributed in the austenite matrix. The volume fraction of former particles was found to be greater than that of the latter. Corrosion studies of the alloy in acidic, chlorides and acidic chloride environments at room temperature indicated that the passivity of Alloy 800 was adversely affected by the addition Cl{sup -} ions. X-ray photoelectron spectroscopy revealed that the surface film formed on the alloy at the onset of passivity consisted of Cr{sup 3+} (as Cr{sub 2}O{sub 3}), without any Fe{sup 3+}/Fe{sup 2+} or Ni{sup 2+}. Scanning electron microscopy studies indicated initiation of pitting at large, faceted particles, not at small, spherical-shaped ones.

2004-12-01

254

Kinetic investigations of graft copolymerization of sodium styrene sulfonate onto electron beam irradiated poly(vinylidene fluoride) films  

Energy Technology Data Exchange (ETDEWEB)

Graft copolymerization of sodium styrene sulfonate (SSS) onto electron beam (EB) irradiated poly(vinylidene fluoride) (PVDF) films was investigated to find out a simple preparation process for sulfonic acid proton exchange membranes with respect to monomer concentration, absorbed dose, temperature, film thickness and storage time. The reaction order of the monomer concentration and absorbed dose of grafting was found to be 2.84 and 1.20, respectively. The overall activation energy for graft copolymerization reaction was calculated to be 11.36 kJ/mol. The initial rate of grafting was found to decrease with an increase in the film thickness. The trapped radicals in the irradiated PVDF films remained effective in initiating the reaction without considerable loss in grafting level up to 180 days, when stored under -60 {sup o}C. The presence and distribution of polystyrene sulfonate grafts in the obtained membranes were observed by Fourier transform infrared (FTIR) spectroscopic analysis, ...

2011-01-15

255

Ising model for phase separation in alloys with anisotropic elastic interaction. 2: A computer experiment  

Energy Technology Data Exchange (ETDEWEB)

When a metallic alloy is quenched into a miscibility gap, a mixture of two phases develops, whose domain structure then coarsens because of the interfacial energy between the two phases. This spatial arrangement of the domains and the rate at which they evolve may be strongly influenced by elastic interactions. In a recent paper, the authors described a method for simulating the effect of anisotropic elastic interactions in a two-dimensional Ising model of a cubic alloy, using Kawasaki dynamics with the elastic interactions represented by a long-range two-body interaction potential. Here they present the results of such simulations at various temperatures, alloy compositions and misfits (by misfit they mean the difference in size between the two kinds of atom), exhibiting snapshots both of the microscopic configurations (corresponding to experimental measurements using transmission electron microscopy) and of their squared Fourier transforms (corresponding to ...

1996-08-01

256

High lithium ion conductive Li7La3Zr2O12 by inclusion of both Al and Si  

British Library Electronic Table of Contents (United Kingdom)

High lithium-ion (Li^+) conductive garnet-structured lanthanum lithium zirconate (LLZ) solid electrolyte is prepared by incorporation of appropriate amounts of silicon (Si) and aluminum (Al). The resultant pelletized LLZ obtains total Li^+ conductivity of 6.8x10^-^4Scm^-^1 at 298K. This improved conductivity is nearly identical with the bulk Li^+ conductivity of the LLZ reported earlier, suggesting that the grain boundary resistance is effectively reduced by the incorporation of Si and Al. Microanalyses by transmission electron microscopy coupled with energy-dispersive X-ray microanalysis and electron energy-loss spectroscopy revealed the presence of amorphous Li-Al-Si-O with nano crystalline LiAlSiO4 at grain boundaries. Fast lithium-ion transport around the amorphous Li-Al-Si-O/LiAlSiO4 ...

2011-01-01

257

Formation of Si-nanoparticles in a microwave reactor: Comparison between experiments and modelling  

International Nuclear Information System (INIS)

The formation and growth of silicon-nanoparticles from silane in a microwave reactor was investigated. Experiments were performed for the following conditions: precursor concentration 380-2530 ppm, pressures of 20-30 mbar, microwave powers 120-300 W. The formed particles were examined in-situ with a particle mass spectrometer. Additionally, particles were collected on grids and analyzed by transmission electron microscopy, X-ray diffraction, and by determining the specific surface area by BET. The particle size was found to be in the range of 5-8 nm in diameter. A simple model was used to simulate the particle formation processes taking place inside the reactor. The microwave energy coupled into the reactor flow was treated as a spatially distributed energy source resulting in a local temperature increase. The particles were assumed to have a monodisperse size distribution. To allow an approximation of their shape they were characterized by ...

2005-02-01

258

Facile synthesis of additive-assisted nano goethite powder and its application for fluoride remediation  

Energy Technology Data Exchange (ETDEWEB)

The present article describes a novel synthesis route for nano-sized goethite ({alpha}-FeOOH) using hydrazine sulphate as an additive. The X-ray diffraction (XRD) peaks of synthesized powder matched well with those of {alpha}-FeOOH. Transmission electron microscopy (TEM) showed the particles of irregular shape in the range of 1-10 nm. Batch adsorption experiments for fluoride uptake were performed to study the influence of various experimental parameters such as contact time (10 min to 7 h), initial fluoride concentration (10-150 mg L{sup -1}), pH (2-11.6) and the presence of competing anions. The time data fitted well to pseudo-second-order kinetic model. The fluoride removal passed through broad maxima in pH ranges of 6-8. High adsorption capacity of 59 mg g{sup -1} goethite was obtained. The isothermic data fitted well to Freundlich model. The presence of other ions namely chloride and sulphate adversely affected fluoride removal. Fluoride ...

2010-02-15

259

Dye-sensitized solar cells based on anatase TiO2 hollow spheres/carbon nanotube composite films  

British Library Electronic Table of Contents (United Kingdom)

Dye-sensitized solar cells (DSSCs) based on anatase TiO2 hollow spheres (TiO2HS)/multi-walled carbon nanotubes (CNT) nanocomposite films are prepared by a directly mechanical mixing and doctor blade method. The prepared samples are characterized by scanning electron microscopy, transmission electron microscopy, X-ray diffraction, UV-vis absorption spectroscopy and N2 adsorption-desorption isotherms. The photoelectric conversion performances of the DSSCs based on TiO2HS/CNT composite film electrodes are also compared with commercial-grade Degussa P25 TiO2 nanoparticles (P25)/CNT composite solar cells at the same film thickness. The results indicate that the photoelectric conversion efficiencies () of the TiO2HS/CNT composite DSSCs are dependent on CNT loading in the electrodes. A small amou...

2011-01-01

260

Develop techniques for ion implantation of PLZT [lead-lanthanum-zirconate-titanate] for adaptive optics  

International Nuclear Information System (INIS)

Research was conducted at Pacific Northwest Laboratory to develop high photosensitivity adaptive optical elements utilizing ion implanted lanthanum-doped lead-zirconate-titanate (PLZT). One centimeter square samples were prepared by implanting ferroelectric and anti-ferroelectric PLZT with a variety of species or combinations of species. These included Ne, O, Ni, Ne/Cr, Ne/Al, Ne/Ni, Ne/O, and Ni/O, at a variety of energies and fluences. An indium-tin oxide (ITO) electrode coating was designed to give a balance of high conductivity and optical transmission at near uv to near ir wavelengths. Samples were characterized for photosensitivity; implanted layer thickness, index of refraction, and density; electrode (ITO) conductivity; and in some cases, residual stress curvature. Thin film anti-ferroelectric PLZT was deposited in a preliminary experiment. The structure was amorphous with x-ray diffraction showing the beginnings of a structure at ...

261

Crystal structure of ball-milled mixture of sodium chloride and magnesium chloride-ethanol adduct  

International Nuclear Information System (INIS)

NaCl doped MgCl_2.nEtOH adducts were prepared by ball-milling MgCl_2.2.5EtOH with NaCl. Both the ball-milled MgCl_2.nEtOH/NaCl mixture and pure MgCl_2.2.5EtOH adducts were analyzed by X-ray diffraction (XRD), transmission electron microscope (TEM), thermogravimetry (TG) and differencial scanning calorimetry (DSC). A simple MgCl_2.nEtOH/NaCl mixture without ball-milling treatment was also studied for comparison. Two kinds of mixed crystals, Na_2MgCl_4 and NaMgCl_3, were found to be formed in a ball-milled mixture that contained 16 mol.% NaCl. TG and DSC analysis of the samples also provided indirect evidences supporting the presence of the mixed crystals in the ball-milled mixture. Adding certain amounts of NaCl in MgCl_2.2.5EtOH adduct, either by co-milling or by simple mixing, greatly increased the thermal stability of the adduct, but thermal decomposition behaviour of the ball-milled mixture was still different from that of a simple mixture.

2008-02-05

262

Comparative study of phase stability and film morphology in thin-film M/GaAs systems (M = Co, Rh, Ir, Ni, Pd, and Pt)  

Energy Technology Data Exchange (ETDEWEB)

To attain reproducible and stable contacts to compound semiconductor devices, it is necessary to achieve thermodynamically stable phases after the reaction of metals with the compound semiconductor. In this study, the final phases produced by the reactions between GaAs and thin metal films of Co, Rh, Ir, Ni, Pd, and Pt have been investigated. They are identified as MGa for M = Co, Rh, Ni, Pd, and Pt, monoarsenides of Co and Ni, diarsenides of Rh, Ir, Pd, and Pt, and Ir/sub 3/Ga/sub 5/. These phases, if deposited directly onto GaAs, will produce thermally stable contacts. In addition to the identification of these stable phases, analyses of the products of thin-film M/GaAs reactions by transmission electron microscopy, x-ray diffraction, and Rutherford backscattering spectrometry reveal the distribution, grain size, and crystallographic texture of these end phases. Trends in these observations across the six metal/GaAs reactions studied are ...

1987-09-01

263

Catalytic behavior of Co/(Nanob-Zeolite) bifunctional catalysts for Fischer-Tropsch reactions  

British Library Electronic Table of Contents (United Kingdom)

Cobalt supported on Beta zeolite catalysts were prepared by impregnation of metal salts in aqueous solution and were tested for the Fischer Tropsch reaction. The support consisted of a Beta zeolite composed by crystallites of nanometric dimensions and a SiO2/Al2O3 molar ratio of about 50. This support was impregnated with Co(NO3)2 aqueous solution using different metal loads of 7.5, 10, 15 and 20wt% Co. These materials were characterized by X-ray diffraction (XRD), high resolution transmission electron microscopy (HRTEM), N2 adsorption (BET), thermal programmed reduction (TPR) and FTIR of adsorbed pyridine (i.e., surface acid sites distribution). All the catalysts showed a significant catalytic activity for the F-T reaction from synthesis gas (CO+2H2), in a continuous fixed bed reactor sys...

2011-01-01

264

Apoferritin-Templated Yttrium Phosphate Nanoparticle Conjugates for Radioimmunotherapy of Cancers  

Energy Technology Data Exchange (ETDEWEB)

We report a templated-synthetic approach based on apoferritin to prepare radionuclide nanoparticle (NP) conjugates. Non-radioactive yttrium (89Y) was used as model target and surrogate for radioyttrium (90Y) to prepare the nanoparticle conjugate. The center cavity and multiple channel structure of apoferritin offer a fast and facile method to precipitate yttrium phosphate by diffusing yttrium and phosphate ions into the cavity of apofrritin, resulting a core-shell nanocomposite. The yttrium phosphate/apoferritin nanoparticle was functionalized with biotin for further application. The synthesized nanoparticle was characterized by transmission electron microscopy (TEM) and x-ray photoelectron spectroscopy (XPS). We found that the resulting nanoparticles were uniform in size, with a diameter of around 8 nm. We tested the pre-targeting capability of the biotin-modified yttrium phosphate/apoferritin nanoparticle (yttrium phosphate/apoferritin ...

2008-05-01

265

Aggregation of silica nanoparticles directed by adsorption of lysozyme.  

Science.gov (United States)

The interaction of the globular protein lysozyme with silica nanoparticles of diameter 20 nm was studied in a pH range between the isoelectric points (IEPs) of silica and the protein (pH 3-11). The adsorption affinity and capacity of lysozyme on the silica particles is increasing progressively with pH, and the adsorbed protein induces bridging aggregation of the silica particles. Structural properties of the aggregates were studied as a function of pH at a fixed protein-to-silica concentration ratio which corresponds to a surface concentration of protein well below a complete monolayer in the complete-binding regime at pH > 6. Sedimentation studies indicate the presence of compact aggregates at pH 4-6 and a loose flocculated network at pH 7-9, followed by a sharp decrease of aggregate size near the IEP of lysozyme. The structure of the bridged silica aggregates was studied by cryo-transmission electron microscopy (cryo-TEM) and small-angle ...

2011-07-20

266

A new fuel cell electrocatalyst based on carbonized polyacrylonitrile foam: The nature of platinum-support interactions  

Energy Technology Data Exchange (ETDEWEB)

X-ray photoelectron spectroscopy (XPS) and transmission electron microscopy (TEM) have been conducted on a new fuel cell electrocatalytic material based on a highly porous carbonized polyacrylonitrile (PAN) microcellular foam with very low platinum loading ({approximately}13 to 23 {micro}g/cm{sup 2}). TEM images of this material clearly show the existence of nanometer size platinum particles which are homogeneously distributed in the highly porous carbonized PAN matrix. An XPS study of Pt-loaded PAN indicates that C 1s, O 1s, and N 1s peaks shift to lower binding energies, compared to virgin PAN. It was concluded that special metal-support interaction exists, through the formation of a charge-transfer complex between platinum and pyridine-type nitrogen atoms of PAN support. This interaction leads to the enhancement of the catalytic activity, and the improvement of the long-time stability of this electrocatalyst.

1997-01-01

267

X-Ray Phase Imaging for Breast Cancer Detection  

Science.gov (United States)

... Accession Number : ADA535309. Title : X-Ray Phase Imaging for Breast Cancer Detection. Descriptive Note : Annual rept. 1 Sep 2009-31 Aug 2010 ...

2010-09-01

268

Tissue oxygenation in a murine SCC VII tumor after X-ray irradiation as determined by EPR spectroscopy  

UK PubMed Central (United Kingdom)

PurposeThe goal of this study was to clarify the dynamics of tumor oxygen (partial pressure of oxygen, pO2) in SCC VII murine tumors in mice after X-ray...Full Text Available

2008-03-01

269

Subacute neuropathological effects of microplanar beams of x-rays from a synchrotron wiggler.  

UK PubMed Central (United Kingdom)

Microplanar beam radiation therapy has been proposed to treat brain tumors by using a series of rapid exposures to an array of parallel x-ray beams, each beam having uniform microscopic thickness and...Full Text Available

1995-09-12

270

Small-Angle X-ray Scattering of Reduced Ribonuclease A: Effects of Solution Conditions and Comparisons with a Computational Model of Unfolded Proteins  

UK PubMed Central (United Kingdom)

The disulfide-reduced form of bovine ribonuclease A (RNAse A), with the Cys thiols irreversibly blocked, was characterized by small-angle x-ray scattering (SAXS). To help resolve the conflicting...Full Text Available

2008-04-11

271

Radionuclide X-ray fluorescence analysis of waste water from the production of citric acid  

Energy Technology Data Exchange (ETDEWEB)

Radionuclide X-ray fluorescence analysis was used for the determination of iron, calcium, potassium, copper, manganese and zinc in waste water from the production process of citric acid.

1982-02-18

272

Radionuclide X-ray fluorescence analysis of waste water from the production of citric acid  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis was used for the determination of iron, calcium, potassium, copper, manganese and zinc in waste water from the production process of citric acid. (author).

1982-02-01

273

Radiation exposure due to X-rays of the hip joint in babies  

International Nuclear Information System (INIS)

Exact anatomic knowledge about the location of the gonads and the application of corresponding measures of radiation protection are the preconditions for an efficient reduction of the danger of a possible genetic damage as a result of radiation exposition during X-ray examination of the hip joint of newborns. (VJ).

274

PIXE analysis of GaAs and ZnSe  

Energy Technology Data Exchange (ETDEWEB)

The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K{sub {alpha}} X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K{sub {alpha}} X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be satisfied in order that the ...

1990-01-01

275

PIXE analysis of GaAs and ZnSe  

International Nuclear Information System (INIS)

The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K_#alpha# X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K_#alpha# X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be satisfied in order that the ...

1989-06-01

276

Numerical optimization of spherical variable-line-spacing grating X-ray spectrometers  

UK PubMed Central (United Kingdom)

Operation of an X-ray spectrometer based on a spherical variable-line-spacing (VLS) grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and...Full Text Available

2011-03-01

277

Noise Characterization of Polycrystalline Silicon Thin Film Transistors for X-ray Imagers Based on Active Pixel Architectures  

UK PubMed Central (United Kingdom)

An examination of the noise of polycrystalline silicon thin film transistors, in the context of flat panel x-ray imager development, is reported. The study was conducted in the spirit of exploring...Full Text Available

2008-01-01

278

Method of describing dose distributions in computer design of teleradiotherapy  

International Nuclear Information System (INIS)

Method for description of X-ray radiation dose distribution based on semiempirical description of dose fields is suggested. At that dose field description parameters can be easily individualized for concrete X-ray device.

279

Measurements of accurate x-ray scattering data of protein solutions using small stationary sample cells  

UK PubMed Central (United Kingdom)

In this paper, we report a method of precise in situ x-ray scattering measurements on protein solutions using small stationary sample cells. Although reduction in the radiation damage...Full Text Available

2009-01-01

280

Magnetic fields of x-ray pulsars  

Energy Technology Data Exchange (ETDEWEB)

An analytic model of magnetic torques applied to an accreting neutron star is employed to evaluate the magnetic dipole moments of x-ray pulsars. A new type of close binary system containing a neutron star is suggested.

1982-09-01

281

Grating-based X-ray phase imaging using multiline X-ray source  

International Nuclear Information System (INIS)

Differential phase-contrast X-ray imaging has been performed in a Talbot-Lau configuration, where a multiline X-ray source was used instead of a combination of a hard-X-ray multiple slit and a normal focus X-ray generator. When the multiple slit is used, a high aspect ratio structure is needed and slit width should be below 10 ?m for its function. The fabrication and use of such a multislit can be omitted using the presented configuration. The multiline X-ray source was developed by making grooves on a tungsten rotating anode, which was irradiated by an electron beam to generate X-rays. An array of 10?m line sources with a pitch of 30?m was formed and combined with a 4.5 ?m pitch phase grating and a 5.3 ?m pitch amplitude grating to generate differential phase contrast. With a total exposure time of 40 s, a differential phase image depicting cartilages was ...

2009-07-01

282

Experimental X-ray intensity ratio L#beta#/L#alpha#  

International Nuclear Information System (INIS)

Experimental, relative intensities for the components of L X-ray were collected from literature, and atomic-number dependency of L#beta#/L#alpha# has been found. (author).

1980-01-01

283

Contribution to the radionuclide x-ray fluorescence analysis of human blood and plasma  

International Nuclear Information System (INIS)

A photon-induced x-ray fluorescence method allowing the simultaneous determination of iron, copper, zinc, bromine and rubidium in human blood and blood plasma samples is described. The method is reliable and has a good sensitivity for a wide range of elements. (author).

1986-04-01

284

Chemical effects on K x-ray intensity ratios in chromium compounds  

International Nuclear Information System (INIS)

K_#beta#/ K_#alpha# x-ray intensity ratio of chromium were measured in different chromium compounds. The results show the variation of the intensity ratio as a function of the chemical environment around the metal ion. (author)

2003-02-10

285

Characterization and catalytic oxidation activity of uranium-bismuth mixed oxides  

International Nuclear Information System (INIS)

Bi-U mixed oxides were synthesized by two methods and characterized by X-ray diffraction and X-ray photoelectron spectroscopy. The samples were tested for the catalytic oxidation of carbon monoxide by oxygen. A stepwise redox mechanism consistent with the kinetic results is proposed. (orig.).

286

APOD: 2002 July 11 - M51: X Rays from the Whirlpool  

Science.gov (United States)

picture will download the highest resolution version available. M51: X-Rays from the Whirlpool Credit: A. Wilson (UMD) et al., CXC, NASA Explanation: Fresh from yesterday's...

2011-10-07

287

A comparison of iterative algorithms and a mixed approach for in-line x-ray phase retrieval  

UK PubMed Central (United Kingdom)

Previous studies have shown that iterative in-line x-ray phase retrieval algorithms may have higher precision than direct retrieval algorithms. This communication compares three iterative phase...Full Text Available

2009-08-15

288

8. Application of radionuclide X-ray fluorescence analysis in other fields of science and technology  

International Nuclear Information System (INIS)

Certain applications are described of radionuclide X-ray fluorescence analysis in the ore dressing industry, in the manufacture of building materials, in metallurgy, pharmacy, in the chemical, photographic and paper industries, in space exploration, in archeology and for measuring the thicknesses of thin layers of coatings. (ES).

1983-12-01

291

Superconducting properties of metallic superlattices  

Energy Technology Data Exchange (ETDEWEB)

The preparation by sputtering of artificial metallic superlattices is described, as are the results of x-ray structural determinations. Tunneling and resistivity measurements on these materials are reported.

1987-01-01

292

Radionuclide X-ray fluorescence analysis using semiconductor detectors  

International Nuclear Information System (INIS)

Czech May 1979. p. 32-33. Czechoslovakia Benada, J. Spacek, B. Ustav

1979-05-01

293
294

Plasma diagnostics in the optical and X-ray regions on the plasma focus device PF-4 (TULIP)  

International Nuclear Information System (INIS)

... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,

2006-09-11

295

Microcomputers in radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Czech Apr 1986. p. 51. Czechoslovakia Cechak, T. Kluson, J. Ceske

1986-04-01

296

Experimental study of X-ray vidicon  

International Nuclear Information System (INIS)

(1972). USSR Sviryakin, DI Manets, AI Kolupaev, AN v. 213 p. 111-114.

298

Electron-induced luminescence and x-ray spectrometer development: progress report  

Science.gov (United States)

The progress in the development of a surface analysis tool based on the excitation of characteristic

2003-01-01

299

Electron-Induced Luminescence and X-Ray Spectrometer (ELXS) System for Life Detection  

Science.gov (United States)

The ELXS concept is a novel, portable, micro-instrument targeted for the detection of mineralogic

2002-01-01

300

Development of high resolution imaging detectors for X-ray astronomy  

Energy Technology Data Exchange (ETDEWEB)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-03-01

301

Development of high resolution imaging detectors for X-ray astronomy  

International Nuclear Information System (INIS)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-01-01

303

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds  

Energy Technology Data Exchange (ETDEWEB)

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds were studied by electron and proton bombardments. L{sub {gamma}1} X-rays which involve transition of 4d electrons of the valence shell were found to be sensitive to the chemical environment. The L{sub {gamma}1}/L{sub {beta}1} X-ray intensity ratio increased with an increase of the 4d electron occupation of niobium or molybdenum in niobium or molybdenum compounds, showing that the chemical effects can be ascribed to the 4d electron behavior of the metallic atom in its compounds. (orig.).

1990-12-20

304

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds  

International Nuclear Information System (INIS)

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds were studied by electron and proton bombardments. L_#gamma#_1 X-rays which involve transition of 4d electrons of the valence shell were found to be sensitive to the chemical environment. The L_#gamma#_1/L_#beta#_1 X-ray intensity ratio increased with an increase of the 4d electron occupation of niobium or molybdenum in niobium or molybdenum compounds, showing that the chemical effects can be ascribed to the 4d electron behavior of the metallic atom in its compounds. (orig.).

1990-12-01

305

X-ray findings in patients with miliary appearance of metallic mercury after suicide attempt  

Energy Technology Data Exchange (ETDEWEB)

This case report evaluates X-ray findings in patients with miliary accumulation of mercury observed after parenteral application of metallic mercury in a suizide attempt. There are certain discrepancies between clinical symptoms and the X-ray findings. A clear demonstration of mercury in coronary blood vessels is possible by fluoroscopy.

1985-03-01

306

The evolution of x-ray binaries  

International Nuclear Information System (INIS)

These proceedings represent papers presented at the Astrophysics Conference in Maryland, USA. The topic of the Conference was the evolution of x-ray binaries and the papers encompass a wide range of subjects on x-ray astronomy. There were one hundred eighteen papers presented at the Conference and out of these three have been abstracted for the Energy Science and Technology database.

1993-10-11

307

Radionuclide X-ray fluorescence analysis of components of the environment  

International Nuclear Information System (INIS)

The physical foundations and methodology are described of radionuclide X-ray fluorescence analysis. The sources are listed of air, water and soil pollution, and the transfer of impurities into biological materials is described. A detailed description is presented of the sampling of air, soil and biological materials and their preparation for analysis. Greatest attention is devoted to radionuclide X-ray fluorescence analysis of the components of the environment. (ES).

1983-01-01

308

Present state of radionuclide X-ray fluorescence analysis in coal mining  

International Nuclear Information System (INIS)

Applications of X-ray fluorescence analysis in coal mining and geology are briefly described based on results published in Czechoslovakia as well as abroad over the past 3 years. Particular attention is paid to the rapid determination of the ash content of coal using portable radionuclide X-ray fluorescence analyzers that are being developed in Czechoslovakia. (author).

1990-01-01

309

Pd-Na/F double exploding foil photoionization experiment  

Science.gov (United States)

The achievement of inner-shell photoionization of Zn-like Pd by means of two exploding foils is described. This resulted in the soft X-ray transition 3d94s2-3d104p at 46 A. It is shown that the photoionization of inner shell electrons in highly stripped ions can lead to X-ray transitions which may be candidates for X-ray lasers under 50 A.

1990-03-01

310

Nondestructive determination of airborne lead particulates by the radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).

1980-01-01

311

Multi-mirror system, 2. Application of inverse Compton Scattering for lithography X-ray sources  

Energy Technology Data Exchange (ETDEWEB)

A brilliant X ray source is proposed for lithography instruments with use of a multi-mirror system. The inverse Compton scattering between the stored electron beam in the storage ring and the stored photon beam in the multi-mirror system, is applied for the X-ray generation. (author)

2000-07-01

312

Measurement of the K?/K? ratio for muon alpha sticking X-rays in muon catalyzed d-t fusion at the RIKEN-RAL Muon Facility  

International Nuclear Information System (INIS)

At the RIKEN-RAL Muon Facility, ?- to ? sticking K? X-rays were observed for the first time taking advantage of the pulsed beam structure. The precision of the present measurements was insufficient to distinguish between theoretical models, however the observed K?/K? X-ray intensity ratio tends to be smaller than most of these theoretical predictions.

1999-06-01

313

Genetic and somatic risks in X-ray diagnosis  

International Nuclear Information System (INIS)

Based on a literature study an actual summary of the risk-utility problems in X-ray diagnosis is outlined due to the Recommendations of the International Commission for Radiation Protection (ICRP publication 26/1977). Papers demonstrating quantitative assessment of the somatic and genetical risk in X-ray examination are preferably cited and evaluated. It is concluded that the somatic and genetical risk is low in diagnostic ratiology. However, it must not be neglected and has always to be compared to the utility of an examination as well as to other risks of the examination. (author).

1982-01-01

314

From tomography to voludensitometry: radiation detectors for industrial control and medical instrumentation; De la tomographie a la voludensitometrie: les capteurs pour le controle industriel et l`instrumentation medicale  

Energy Technology Data Exchange (ETDEWEB)

In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).

1993-12-01

315

Determination of ash in coal by X-ray backscattering and X-ray fluorescence analysis and apparatus by the PAR company  

International Nuclear Information System (INIS)

The basic principles of determination of the ash content of coal by the title methods are outlined. A brief technical characteristic of the ash meters and radionuclide X-ray fluorescence analyzers manufactured by the PAR company is presented. (Z.S.). 4 figs., 7 refs.

1993-01-01

316

Contribution to the in vitro multielement X-ray fluorescence analysis of human soft tissues  

International Nuclear Information System (INIS)

Determination of Mn, Fe, Ni, Cu, Zn, and Pb in human soft tissues by radionuclide X-ray fluorescence analysis (using "2"3"8Pu and "1"0"9Cd sources) is described. The results of multielement XRS analysis of selected human tissues are tabulated. They are in good agreement with the literature data. It is concluded that X-ray fluorescence technique is a suitable method for trace element determination. (author).

1986-11-01

317

Optimization of X-ray energy resolution from a horizontally focused single-crystal monochromator  

Energy Technology Data Exchange (ETDEWEB)

A method has been developed to optimize the energy resolution of a horizontally focusing monochromator. The method consists of determining the optimum radius of curvature of the cylindrically bent monochromator crystal by minimizing the total diffracted X-ray flux measured through an X-ray absorption foil. When measured at an absorption edge a global minimum can be identified, which corresponds to the minimum energy band accepted along the entire length of the crystal. Experimental verification of this method has been validated by comparing X-ray fluorescent scans taken for a series of crystal curvatures and by directly measuring the X-ray beam profiles at the corresponding points. The actual optical configuration and asymmetric-cut parameter of the focusing monochromator on beamline X4C at the National Synchrotron Light Source are modeled and ray tracing simulations of the optical system are compared ...

2009-02-11

318

Miniature x-ray source  

Energy Technology Data Exchange (ETDEWEB)

A miniature x-ray source utilizing a hot filament cathode. The source has a millimeter scale size and is capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature source consists of a compact vacuum tube assembly containing the hot filament cathode, an anode, a high voltage feedthru for delivering high voltage to the cathode, a getter for maintaining high vacuum, a connector for initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is fabricated from highly x-ray transparent materials, such as sapphire, diamond, or boron nitride.

2000-01-01

319

Gauging film thickness: A comparison of an x-ray diffraction technique with Rutherford backscattering spectrometry  

Energy Technology Data Exchange (ETDEWEB)

An x-ray diffraction technique for determining thin-film thickness is presented which should prove to be a valuable alternative to the array of spectroscopies (Rutherford backscattering spectrometry, Auger electron spectroscopy, etc.) currently favored for these measurements. Some of the virtues of this x-ray diffraction approach are its nondestructive nature, fast data acquisition rate (enabling in situ observations), thickness resolution better than 5 nm, and conventional equipment requirements. Results are shown for Pd/sub 2/Si thin films grown during isothermal annealing of Pd coatings (100 nm) on Si at 200 /sup 0/C for various amounts of time. A comparison of these x-ray measurements with Rutherford backscattering spectrometry data taken from the same specimens is used to demonstrate the validity of the x-ray technique.

1985-01-15

320

Measurement of the L sub 2 - L sub 3 Coster-Kronig transition probability in Tm( Z =69)  

Energy Technology Data Exchange (ETDEWEB)

The {ital L}{sub 2}-{ital L}{sub 3} Coster-Kronig transition probability ({ital f}{sub 23}) in Tm was measured by multiparameter {ital K} versus {ital L} x-ray coincidence techniques. The Tm x rays were obtained from a radioactive source of {sup 169}Yb and were detected with cooled germanium and silicon detectors of high-energy resolution. Corrections were applied for the contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak and for the contribution of unresolved {ital L}{eta} x rays to the {ital L}{alpha}{sub 1,2} x-ray peak. The contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak was determined solely from the results of the coincidence measurements using a method of ...

1989-11-01

321

Measurement of the L sub 2 - L sub 3 Coster-Kronig transition probability in Tm( Z =69)  

Science.gov (United States)

The {ital L}{sub 2}-{ital L}{sub 3} Coster-Kronig transition probability ({ital f}{sub 23}) in Tm was measured by multiparameter {ital K} versus {ital L} x-ray coincidence techniques. The Tm x rays were obtained from a radioactive source of {sup 169}Yb and were detected with cooled germanium and silicon detectors of high-energy resolution. Corrections were applied for the contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak and for the contribution of unresolved {ital L}{eta} x rays to the {ital L}{alpha}{sub 1,2} x-ray peak. The contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak was determined solely from the results of the coincidence measurements using a method of ...

1989-11-01

322

X-ray and UV-light irradiation effects on oxide superconducting thin films  

International Nuclear Information System (INIS)

Oxide superconducting thin films were irradiated with X-rays and ultra-violet (UV) light, and induced radiation effects on electrical and chemical properties were examined by transport measurement, X-ray diffraction analysis (XRD), diamagnetization measurement and X-ray photoemission spectroscopy (XPS). After irradiation for ErBa_2Cu_3O_x films with X-rays emitted from a Rh tube for 100 hours, superconductivity was remarkably damaged, destroying the zero-resistance state. The UV-light irradiation for Bi_2Sr_2CaCu_2O_x films was performed in He gas of about 500 Pa with a low pressure mercury lamp. The superconductivity was gradually degraded with the UV irradiation time up to 70 minutes. In both cases, adequate oxygen-annealing treatments restored superconductivity. The X-ray photoemission spectra showed that the mean Cu valence of the films was decreased approximately from +2 to +1 ...

323

Portable fluid X-ray diagnostic system  

Energy Technology Data Exchange (ETDEWEB)

A portable X-ray image system is described comprising: (a) a base assembly including panels and hinges joining the panels together along edges, and compression stops for biasing the hinges to compensate for the weight of payload when mounted on the base assembly, the compression stops being located for interaction with the hinges for biasing the panels to exhibit upward bowing when laid upon a flat surface prior to loading, and to provide resiliency for facilitating the base assembly assuming a substantially flat configuration when a predetermined payload is placed upon the base assembly; (b) an X-ray member; (c) apparatus for detachably mounting a table member to the base assembly to hold the table member at a location above the base; (d) an X-ray source; (e) means for sensing X-rays to form an image; (f) means for mounting the X-ray source and the X-ray ...

1989-02-14

324

Development of a dual-detector X-ray imaging system for phase retrieval study  

International Nuclear Information System (INIS)

Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two detectors, respectively ...

2007-01-01

325

DETECTION OF AN X-RAY PULSATION FOR THE GAMMA-RAY PULSAR CENTERED IN CTA 1  

International Nuclear Information System (INIS)

We report the detection of X-ray pulsations with a period of ?315.87 ms from the 2009 XMM-Newton observation for the radio-quiet ?-ray pulsar, LAT PSR J0007+7303, centered in the supernova remnant CTA 1. The detected pulsed period is consistent with the ?-ray periodicity at the same epoch found with the Fermi Gamma-ray Space Telescope. The broader sinusoidal structure in the folded light curve of the X-ray emission is dissimilar to that of the ?-ray emission, and the phase of the peak is about 0.5 shifting from the peak in the ?-ray bands, indicating that the main component of the X-rays originates from different sites of the pulsar. We conclude that the main component of the X-ray pulsation is contributed by the thermal emission from the neutron star. Although with a significantly different characteristic age, PSR J0007+7303 is similar to Geminga in emission properties of X-rays ...

2010-12-10

326

Application of imaging plate technology for NDT; Imaging plate gijutsu to sono oyo  

Energy Technology Data Exchange (ETDEWEB)

This paper describes Fuji computed radiography (FCR) of Fuji Film for NDT (non-destructive testing). Imaging plate (IP) is a two-dimensional detector of X-ray, and shows higher photographic sensitivity than X-ray film. The output emission of IP provides a good linear relationship to X-ray intensity in a wide intensity range. When this emission can be digitized, the X-ray intensity can be also digitized. IP is applied to NDT as an inspection using X-ray. FCR provides higher photographic sensitivity than the conventional X-ray film method, which results in one-fifth to one-twentieth of irradiation time. Images with stable density can be obtained independent of the intensity. Since IP has a wide dynamic range, the variation of X-ray intensity of 1:500 can be expressed in a single image by single shot. High density record including 1000 images ...

1998-10-01

327

Neutron Resonance Parameters of 55Mn from Reich-Moore Analysis of Recent Experimental Neutron Transmission and Capture Cross Sections  

Energy Technology Data Exchange (ETDEWEB)

High-resolution neutron capture cross section measurements of 55Mn were recently performed at GELINA by Schillebeeckx et al. (2005) and at ORELA by Guber et al. (2007). The analysis of the experimental data was performed with the computer code SAMMY using the Bayesian approach in the resonance parameters representation of the cross sections. The neutron transmission data taken in 1988 by Harvey et al. (2007) and not analyzed before were added to the SAMMY experimental data base. More than 95% of the s-wave resonances and more than 85% of the p-wave resonances were identified in the energy range up to 125 keV, leading to the neutron strength functions S0 = (3.90 0.78) x 10-4 and S1 = (0.45 0.08) x 10-4. About 25% of the d-wave resonances were identified with a possible strength function of S2 = 1.0 x 10-4. The capture cross section calculated at 0.0253 eV is 13.27 b, and the capture resonance integral is 13.52 0.30 b. In the energy range 15 to ...

2008-05-01

328

High density of nanodots on atomically flat CeO_2 buffer layers for inducing effective vortex-pinning centers in YBa_2Cu_3O_7_-_#delta# films on sapphire  

International Nuclear Information System (INIS)

Epitaxial CeO_2 buffer layers were fabricated by pulsed laser deposition (PLD) on r-cut sapphire substrates. An atomically flat CeO_2 surface with a high density of nanodots was formed by a self-assembly process. Scanning transmission electron microscopy and energy-dispersive X-ray spectroscopy investigation showed that the nanodots were CeO_2 other than impurities. YBa_2Cu_3O_7_-_#delta# (YBCO) thin films were then grown on the annealed and the as-grown CeO_2-buffered sapphires by PLD. The transport measurement results showed that the nanodots enhanced the effective pinning potential and significantly increased critical current density (J _c). Especially, YBCO films with an annealed CeO_2 buffer layer showed a high J _c peak when the applied field was directed along the c-axis of YBCO. Cross-section transmission electron microscopy investigation revealed that the J _c peaks in YBCO with annealed CeO_2 buffer layer is ...

2006-12-05

329

Status of the WAND (Waste Assay for Nonradioactive Disposal) project as of July 1997  

Energy Technology Data Exchange (ETDEWEB)

The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole system and to perform the data analysis. WAND system minimum detectable activities (MDAs) for point sources range from ...

1998-03-01

330

Semi-empirical simulation of thermoluminescent response under different filter geometries; Simulacao semi-empirica da resposta termoluminescente sob diferentes geometrias de filtro  

Energy Technology Data Exchange (ETDEWEB)

Many thermoluminescent materials has been developed and used for photon personal dosimetry but no one has all desired characteristics alone. These characteristics include robustness, high sensitivity, energy photon independence, large range of photon energy detection, good reproducibility, small fading and simple glow curve with peaks above 150 deg C. Calcium Sulfate Dysprosium doped (CaSO{sub 4}:Dy) phosphor Thermoluminescent Dosimeter (TLD) has been used by many laboratories, mainly in Brazil and India. Another interesting phosphor is Calcium Fluoride (CaF{sub 2}). These phosphor advantages begin to be more required and its disadvantages have became more apparent, in a global market more and more competitive. These phosphors are used in environmental and area monitoring, once they present more sensibility than other phosphors, like LiF:Mg. Theirs mainly disadvantage is a strong energetic dependence response, which must be corrected for theirs application in the field, where photon ...

2006-07-01

331

In situ texture analysis under applied load  

International Nuclear Information System (INIS)

The in-situ measurement of a crystallographic texture is a special type of a non-destructive measurement, which need special equipments. Due to the high photon flux and the excellent brilliance high energetic synchrotron radiations are a fantastic tool particular in fast experimentation. Moreover, a high penetration power allows the investigation of standard tensile sample of the DIN-norm. A loading device with a power up to 20 kN was installed at the hard wiggler beamline BW5 (HASYLAB-DESY) to perform in-situ strain and in-situ texture analysis. Using 100keV X-rays one gets short wavelength so that a 2D image-plate detector offers a wide range of diffraction pattern within the first 10 degree in 2 theta. Thermal neutron is another radiation with a high penetration power, which is the standard method for global texture analysis of bulk samples. As an example rectangular extruded Mg- Az31 was investigated by an in-situ. tensile experiment. ...

332

Central engine of quasars and AGNs: a relativistic proton radiative shock  

International Nuclear Information System (INIS)

Active galactic nuclei (AGNs) and quasars (QSOs) appear to emit roughly equal energy per decade from radio to gamma-ray energies (e.g. Ramaty and Ligenfelter 1982). This argues strongly for a nonthermal radiation mechanism (see Rees 1984). In addition, statistical studies have indicated that the spectra of these objects in the IR-UV and 2 to 50 keV x-ray band, can be fitted very well with power laws of specific indices. These spectral indices do not seem to depend on the luminosity or morphology of the objects (Rothschild et al. 1983; Malkan 1984), and any theory should account for them in a basic and model independent way. If shocks accelerate relativistic protons via the first-order Fermi mechanism (e.g. Axfor 1981), the radiating electrons can be produced as secondaries throughout the source by proton-proton (p-p) collisions and pion decay, thus eliminating Compton losses (Protheroe and Kazanas 1983). As shown by Kazanas (1984), if ...

1985-08-01

333

An overview of the development of the first wall and other principal components of a laser fusion power plant  

International Nuclear Information System (INIS)

This paper introduces the JNM Special Issue on the development of a first wall for the reaction chamber in a laser fusion power plant. In this approach to fusion energy a spherical target is injected into a large chamber and heated to fusion burn by an array of lasers. The target emissions are absorbed by the wall and encapsulating blanket, and the resulting heat converted into electricity. The bulk of the energy deposited in the first wall is in the form of X-rays (1.0-100 keV) and ions (0.1-4 MeV). In order to have a practical power plant, the first wall must be resistant to these emissions and suffer virtually no erosion on each shot. A wall candidate based on tungsten armor bonded to a low activation ferritic steel substrate has been chosen as the initial system to be studied. The choice was based on the vast experience with these materials in a nuclear environment and the ability to address most of the key remaining issues with existing ...

2005-12-15

334

The effect of boron implant energy on transient enhanced diffusion in silicon  

Energy Technology Data Exchange (ETDEWEB)

Transient enhanced diffusion (TED) of boron in silica after low energy boron implantation and annealing was investigated using boron-doping superlattices (DSLs) grown by low temperature molecular beam epitaxy. Boron ions were implanted at 5, 10, 20, and 40 keV at a constant dose of 2{times}10{sup 14}/cm{sup 2}. Subsequent annealing was performed at 750{degree}C for times of 3 min, 15 min, and 2 h in a nitrogen ambient. The broadening of the boron spikes was measured by secondary ion mass spectroscopy and simulated. Boron diffusivity enhancement was quantified as a function of implant energy. Transmission electron microscopy results show that {l_angle}311{r_angle} defects are only seen for implant energies {ge}10 keV at this dose and that the density increases with energy. DSL studies indicate the point defect concentration in the background decays much slower when {l_angle}311{r_angle} defects are present. These results ...

1997-02-01

335

Effect of the Ge preamorphization dose on boron diffusion and defect evolution in silicon  

Energy Technology Data Exchange (ETDEWEB)

In this paper, we study the effect of the Ge{sup +} preamorphization dose on boron diffusion and on the thermal evolution of end of range (EOR) defects during annealing. Amorphizations were carried out by implanting Ge{sup +} at 150 keV to doses ranging from 1x10{sup 15} to 8x10{sup 15} ions/cm{sup 2}. Boron was subsequently implanted at 3 keV with a dose of 1x10{sup 14} ions/cm{sup 2}. Rapid thermal annealing (RTA) was performed for various time/temperature combinations in nitrogen ambient. Secondary ion mass spectroscopy (SIMS) and transmission electron microscopy (TEM) were used to study boron diffusion and defect evolution, respectively. We have found that after a given annealing, both the defect size and boron diffusivity are independent on the Ge ion dose. Increasing this dose only results in an increase of the defect density. These results are discussed and definitely show that EOR defects are involved in a ...

2002-01-01

336

Effect of the Ge preamorphization dose on boron diffusion and defect evolution in silicon  

International Nuclear Information System (INIS)

In this paper, we study the effect of the Ge"+ preamorphization dose on boron diffusion and on the thermal evolution of end of range (EOR) defects during annealing. Amorphizations were carried out by implanting Ge"+ at 150 keV to doses ranging from 1x10"1"5 to 8x10"1"5 ions/cm"2. Boron was subsequently implanted at 3 keV with a dose of 1x10"1"4 ions/cm"2. Rapid thermal annealing (RTA) was performed for various time/temperature combinations in nitrogen ambient. Secondary ion mass spectroscopy (SIMS) and transmission electron microscopy (TEM) were used to study boron diffusion and defect evolution, respectively. We have found that after a given annealing, both the defect size and boron diffusivity are independent on the Ge ion dose. Increasing this dose only results in an increase of the defect density. These results are discussed and definitely show that EOR defects are involved in a quasi-conservative Ostwald ripening ...

2002-01-01

337

Corrosion behaviour of molybdenum-implanted stainless steel  

Energy Technology Data Exchange (ETDEWEB)

A low-molybdenum austenitic stainless steel (UNS S30100) has been surface implanted with molybdenum ions, using various doses of 50 keV and 140 keV ions at room temperature. It is found that in aqueous sulphate/chloride solutions similar to the constitution of sea-waters the implantation does not affect the potentiostatically-determined critical pitting potential, but does change the density and morphology of corrosion pits. Pitting initiation after the addition of chloride at a fixed potential indicates little change in the time for measurable current increase, but the rate of increase of the current is much lower for implanted material. Detailed examination using optical microscopy, scanning electron microscopy, transmission electron microscopy and selected area diffraction suggests that the pits produced in implanted material are hemispherical with smooth covers of unattacked alloy. The use of half-implanted samples ...

1990-01-01

338

Corrosion behaviour of molybdenum-implanted stainless steel  

International Nuclear Information System (INIS)

A low-molybdenum austenitic stainless steel (UNS S30100) has been surface implanted with molybdenum ions, using various doses of 50 keV and 140 keV ions at room temperature. It is found that in aqueous sulphate/chloride solutions similar to the constitution of sea-waters the implantation does not affect the potentiostatically-determined critical pitting potential, but does change the density and morphology of corrosion pits. Pitting initiation after the addition of chloride at a fixed potential indicates little change in the time for measurable current increase, but the rate of increase of the current is much lower for implanted material. Detailed examination using optical microscopy, scanning electron microscopy, transmission electron microscopy and selected area diffraction suggests that the pits produced in implanted material are hemispherical with smooth covers of unattacked alloy. The use of half-implanted samples ...

1989-09-01

339

Reactions of the inner surface of carbon nanotubes and nanoprotrusion processes imaged at the atomic scale  

British Library Electronic Table of Contents (United Kingdom)

Although the outer surface of single-walled carbon nanotubes (atomically thin cylinders of carbon) can be involved in a wide range of chemical reactions, it is generally thought that the interior surface of nanotubes is unreactive. In this study, we show that in the presence of catalytically active atoms of rhenium inserted into nanotubes, the nanotube sidewall can be engaged in chemical reactions from the inside. Aberration-corrected high-resolution transmission electron microscopy operated at 80?keV allows visualization of the formation of nanometre-sized hollow protrusions on the nanotube sidewall at the atomic level in real time at ambient temperature. Our direct observations and theoretical modelling demonstrate that the nanoprotrusions are formed in three stages: (i) metal-assisted d...

2011-01-01

340

Depth dependence of {l_brace}311{r_brace} defect dissolution  

Energy Technology Data Exchange (ETDEWEB)

A deep band of {l_brace}311{r_brace} defects was created 520 nm below the silicon surface with a 350 keV Si implant followed by a cluster-forming rapid thermal anneal (800 C, 1000 s). Chemical etching was used to vary the depth to the surface of the {l_brace}311{r_brace}-defect band. Afterwards, the defect dissolution was investigated at 750 C for different times. Varying the depth in this fashion assures that only the depth and no other feature of the cluster distribution is changed. The {l_brace}311{r_brace} defects were analyzed by plan-view, transmission electron microscopy. We show that the dissolution time of the {l_brace}311{r_brace}-defect band varies linearly with depth, confirming that surface recombination controls the dissolution and is consistent with analogous observations of transient enhanced diffusion.

2001-09-03

341

Depth dependence of #left brace#311#right brace# defect dissolution  

International Nuclear Information System (INIS)

A deep band of #left brace#311#right brace# defects was created 520 nm below the silicon surface with a 350 keV Si implant followed by a cluster-forming rapid thermal anneal (800 C, 1000 s). Chemical etching was used to vary the depth to the surface of the #left brace#311#right brace#-defect band. Afterwards, the defect dissolution was investigated at 750 C for different times. Varying the depth in this fashion assures that only the depth and no other feature of the cluster distribution is changed. The #left brace#311#right brace# defects were analyzed by plan-view, transmission electron microscopy. We show that the dissolution time of the #left brace#311#right brace#-defect band varies linearly with depth, confirming that surface recombination controls the dissolution and is consistent with analogous observations of transient enhanced diffusion.

2001-09-03

342

Use of x-ray imaging for evaluation of superconducting ceramics fabricated by PIT method  

Energy Technology Data Exchange (ETDEWEB)

High-spatial-resolution microfocus-based X-ray imaging technology, both real-time and film, has been used to study the thickness variation that occurs in the oxide core of silver-sheathed BSCCO ribbons produced by the powder-in-tube method. This thickness variation (also called ``sausaging``) occurs during incremental rolling and degrades the critical current densities of the ribbons. Using X-ray image data the authors determined the onset and severity of sausaging. Onset occurred at a ribbon thickness of 203 {micro}m, and the severity increased with subsequent rolling reductions. Scanning electron microscopy was used to confirm the X-ray image data. X-ray imaging provides several advantages over more traditional methods for characterizing the superconductors such as optical or scanning electron microscopy. The X-ray imaging provides nondestructive information about the entire width ...

1993-08-01

343

A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: a theoretical study on 10-MV X-ray dose calculations in thorax-like phantoms  

British Library Electronic Table of Contents (United Kingdom)

A convolution/superposition method is proposed for use with primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. It should be noted that the number of energy bins is usually about ten, and that the reconstructed X-ray spectra can reasonably be applied to media with a wide range of effective Z numbers, ranging from water to lead. The study was carried out for 10-MV X-ray doses in water and thorax-like phantoms with the use of open-jaw-collimated fields. The dose calculations were made separately for primary, scatter, and electron contamination dose components, for which we used two extended radiation sources: one was on the X-ray target and the other on the flattening filter. To calculate the in-air beam intensities at po...

2011-01-01

344

X-ray fluorescence analysis as auxiliary method of restorers  

International Nuclear Information System (INIS)

The principle is described of X-ray fluorescence analysis and the manner of detecting the emitted characteristic radiation. The advantages are presented of radionuclide X-ray fluorescence analysis which consist primarily in the possibility of conducting a totally non-destructive analysis, and of accurate and relatively narrow localization of the analyzed area, the simultaneous qualitative and quantitative determinations of a large number of elements in the order of concentrations 10"1 to 10"-"4%, stability of excitation radiation flux, simple design and relatively low capital costs. The so-called matrix effect is pointed to. A number of examples is given of the use of the cited method, including its use in the analysis of art objects. (J.B.).

1987-09-07

345

Standard samples for X-ray radiometric analysis of substance composition  

International Nuclear Information System (INIS)

Some aspects of metrological provision of X-ray radiometric analyzers for mineral raw composition and gamma-gamma-logging equipment are considered. Standard samples (SS) based on the phenol-formaldehyde resin with the introduced quantities calculated of element compositions in the form of oxides and salts are described. Principles of metrological provision developed are used when carrying out state acceptance tests of X-ray radiometric analyzer RAL-M-102 ''Ehkran'' and gamma-gamma-logging equipmnt RSK-102. Economic benefit from introduction of an SS set is #approx# 60-100 thousand roubles per year.

346

Soft x-ray microradiography and lithograph using a laser produced plasma source. Final report  

Energy Technology Data Exchange (ETDEWEB)

Considering the hardware characteristics of the laser-induced plasma X-ray source and the limitations of the conventional cone-beam reconstruction algorithm, a general cone-beam reconstruction algorithm has been developed at our laboratory, in which the motion locus of the X-ray source is an arbitrary curve corresponding to at least a 2{pi} continuous horizontal angular displacement in the coordinate system of the specimen. The preliminary simulation shows that the general cone-beam reconstruction algorithm consistently results in visually satisfactory images.

1992-03-01

347

Soft x-ray microradiography and lithograph using a laser produced plasma source  

Energy Technology Data Exchange (ETDEWEB)

Considering the hardware characteristics of the laser-induced plasma X-ray source and the limitations of the conventional cone-beam reconstruction algorithm, a general cone-beam reconstruction algorithm has been developed at our laboratory, in which the motion locus of the X-ray source is an arbitrary curve corresponding to at least a 2{pi} continuous horizontal angular displacement in the coordinate system of the specimen. The preliminary simulation shows that the general cone-beam reconstruction algorithm consistently results in visually satisfactory images.

1992-01-01

348

Role of nuclear medicine bone scans in evaluating pain in athletic injuries  

Energy Technology Data Exchange (ETDEWEB)

The utilization of nuclear medicine bone scanning examinations early in the diagnostic process allows physicians to render prompt and correct treatment in urgent or difficult athletic cases. Bone scanning should be performed for athletic injuries whenever (1) x-rays are normal but bone or joint pain persists; (2) x-rays are positive but it cannot be determined if the findings are acute or chronic; (3) soft-tissue injuries present and x-rays are not useful; and (4) bone pain or joint impairment present without a history of trauma.89 references.

1987-10-01

349

Radiological protection. Textbook for radiographers and reference book for radiological safety officers  

International Nuclear Information System (INIS)

The textbook is primarily intended for radiologic staff and radiologic safety officers and gives information on the current regulatory provisions of the German X-ray Ordinance, applications of X-rays, quality assurance, organisational aspects of film processing and quality requirements of X-rays. An annex lists the guidelines of the Bundesaerztekammer (German National Chamber of Physicians) relating to quality assurance aspects, and further useful information on commercially available film-screen systems, the various associations of physicians in Germany, and requirements and performance of radiation surveys. (vhe).

350

Radiation-protection survey guide: fixed radiographic unit. Final report, June 1980-April 1985  

Energy Technology Data Exchange (ETDEWEB)

Prior to routine use, all newly installed x-ray machines must have a radiation-protection survey by a qualified expert. The survey is an evaluation of existing or potential radiation hazards associated with the use of diagnostic x-ray equipment under specific conditions. Such evaluation includes the measurement of exposure levels in the environment as well as environmental levels arising from operation of the equipment. The survey also includes an evaluation of the safety characteristics of the x-ray unit.

1985-05-01

351

Patient doses in the Netherlands. [X-ray diagnosis and radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

Contributions to the population dose due to medical applications of ionising radiation are presented. It appears that contributions due to radiotherapy and X ray diagnosis are of comparable magnitude. To account for the age dependency of the radiation risks, contributions in terms of somatically significant dose equivalent are calculated as 0.3 mSv per caput per annum for X ray diagnosis and as 0.2 mSv per caput per annum for radiotherapy, the latter referring to only doses to organs outside the target volume. (author).

1991-01-01

352

Measurement of the K{sub {beta}}/K{sub {alpha}} ratio for muon alpha sticking X-rays in muon catalyzed d-t fusion at the RIKEN-RAL Muon Facility  

Energy Technology Data Exchange (ETDEWEB)

At the RIKEN-RAL Muon Facility, {mu}{sup -} to {alpha} sticking K{sub {beta}} X-rays were observed for the first time taking advantage of the pulsed beam structure. The precision of the present measurements was insufficient to distinguish between theoretical models, however the observed K{sub {beta}}/K{sub {alpha}} X-ray intensity ratio tends to be smaller than most of these theoretical predictions.

1999-06-15

353

L-subshell and total M-shell X-ray production cross sections of Ta, W, Pt, Au, Pb and Bi by 0.7-2.4 MeV protons  

International Nuclear Information System (INIS)

The L-subshell and total M-shell X-ray production cross sections of Ta, W, Pt, Au, Pb and Bi have been measured by protons of energy between 0.7 and 2.4 MeV. The obtained results for X-ray production cross sections have been compared with the existing experimental data, prediction of the ECPSSR theory and also with fitted empirical cross sections of Strivay and Weber.

2006-06-01

354

Inner-shell excitation of intrinsic luminescence and resonantly excited X-ray fluorescence at Be 1s edge in oriented BeO crystals  

International Nuclear Information System (INIS)

The results of studies of the time-resolved luminescence of self-trapped excitons (STE) with different multiplicity as well as the X-ray emission in oriented BeO crystals under excitation in the vicinity of the 1 s Be photoabsorption edge are presented. The branching of the electronic excitations relaxation depends strongly on the crystal orientation after the inner-shell excitation. The common features between the processes of the STE luminescence and resonantly excited X-ray fluorescence have been discussed.

2007-05-21

355

Estimation of X-rays dose in the crystals of final thickness  

International Nuclear Information System (INIS)

A calculation method of the X-ray radiation dose (energy of gamma- radiation remains in the range of energies where the mechanism of photoelectric absorption is the prevailing one) absorbed in the absorbers of final thickness is suggested. Calculations of resorption of secondary radiation (characteristic fluorescences) in the substance and kinetic energy of photoelectrons caused by this resorption (it would be enough to consider one or two hard series) are presented. Calculation of the spectrum of photoelectron energy yield in TeInSe_2 monocrystal for 0.1-0.5 A range of X-ray radiation is conducted by the developed methods.

356

Emission Line Spectra in the Soft X-Ray Region 20-75 (Angstrom)  

Energy Technology Data Exchange (ETDEWEB)

As part of a project to complete a comprehensive catalogue of astrophysically relevant emission lines in support of new-generation X-ray observatories using the Lawrence Livermore electron beam ion traps EBIT-I and EBIT-II, we studied emission lines of argon and sulfur in the soft X-ray and extreme ultraviolet region. Here we present observations of Ar IX through Ar XVI and S VII through S XIV between 20 and 75 {angstrom} to illustrate our work.

2002-06-18

357

Applications of X-ray scattering in pharmaceutical science  

British Library Electronic Table of Contents (United Kingdom)

The use of X-ray scattering techniques in pharmaceutical science is increasing, in part through increased collaborations with the materials science community, and through increased availability of instrumentation, particularly synchrotron sources. The ability to understand not only the biopharmaceutical outcome, but also arguably, more importantly, the structural aspects of drugs and drug delivery systems, is essential to progressing pharmaceutical science; this review serves as an introduction to the major techniques and the wide range of areas in which X-ray scattering may be applied in understanding and controlling structure in pharmaceutical systems.

2011-01-01

358

Analytic description of X-ray fluorescence intensity as a function of the particle size in powder samples and pulp upon X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Analytic expression is derived for X-ray fluorescence dependence on the particle size of powder and slurry media. The expression is obtained for a model of powder medium containing particles of different size and random distribution in the bulk of the sample. Limiting cases of homogeneous and slurry-like media are considered and expressions for calculation of the fluorescence intensity are derived. The results reasonably match the experiment for binary powder mixtures and thus provide evaluation of the powder particle size on the fluorescence intensity for multicomponent polydisperse powder medium

2007-11-01

359

A Virtual Young's Double Slit Experiment for Hard X-ray Photons  

CERN Document Server

We have implemented a virtual Young's double slit experiment for hard X-ray photons with micro-fabricated bi-prisms. We observe fringe patterns with a scintillator, and quantify interferograms by detecting X-ray fluorescence from a scanned 30nm Cr metal film. The observed intensities are best modeled with a near-field, Fresnel analysis. The maximum fringe number in the overlap region is proportional to the ratio of real to imaginary parts refractive index of the prism material. The horizontal and vertical transverse coherence lengths at beamline APS 8-ID are measured.

2009-01-01

360

3. Physical foundations and methodology of radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The physical foundations are described of radionuclide X-ray fluorescence analysis (RXFA) and the table shows the values of K- and L-absorption thresholds and the K- and L-line energies of elements. The calculation of the intensity of characteristic radiation during RXFA proceeds from relations derived for conventional X-ray fluorescence analysis. The choice of the radionuclide source is ruled by the nature of the analysed substance and the used detection technique. The diagram shows the areas of radionuclide sources and the energy of the fluorescence radiation of elements. The table shows the spectra of radionuclide sources suitable for the purposes of RXFA measured by semiconductor Si(Li) and Ge(Li) detectors. (ES).

1983-12-01

361

X-ray Emission as a Probe of the Wind-Driven Shock in WR 140  

Science.gov (United States)

single star evolution. To understand the evolution of massive stars and their role in shaping the galaxy, understanding of the distribution of ...

362

What can we learn about extragalactic radio jets from X-ray data?  

CERN Document Server

We review the current status of resolved X-ray emission associated with extragalactic radio jets and hotspots. The primary question for any particular jet is to decide if the X-rays come from the synchrotron process or from inverse Compton scattering. There is considerable evidence supporting synchrotron emission for knots in the jets of FRI galaxies. For FRII terminal hotspots detected in the X-ray band, synchrotron self-Compton emission continues to provide viable models with one possible exception (so far). Inverse Compton scattering on photons of the cosmic microwave background is indicated for a few powerful jets, and is expected to be an important contributor if not the dominating mechanism for higher redshift objects. The application of a model generally yields physical parameters and in many cases, these include the Doppler boosting factor.

2003-01-01

364

Trace analysis in cadmium telluride by heavy ion induced X-ray emission and by SIMS  

International Nuclear Information System (INIS)

The possibilities of using both selective heavy ion induced X-ray emission and secondary ion mass spectroscopy (SIMS), for the identification of impurities present at low concentrations in cadmium telluride are examined. The relative concentrations of the impurities along CdTe crystals have been determined by exciting the X-ray emission of the elements in several slices with Ar and Kr ions and by comparing the relative characteristic X-ray emission yields. As a consequence of the quasimolecular inner shell ionization mechanism in heavy ion-atom collisions, Ar and Kr ions allow a strong excitation of the main impurities seen by SIMS namely Si, Cl and Ge, As, with only a minor contribution of Cd and Te. From the changes of the concentrations of the various impurities along the crystal, informations about segregation coefficients and compensation can be obtained.

2007-02-01

365

Thermal and Electromigration-Induced Strains in Polycrystalline Films and Conductor Lines X-ray Microbeam Measurements and Analysis  

CERN Document Server

Thermal and Electromigration-Induced Strains in Polycrystalline Films and Conductor Lines

2006-01-01

367

The Effects of Long Term Storage on Special Purpose Lead ...  

Science.gov (United States)

... Special Purpse Lead Azide Lot #I3A-4-62 ... Standard X-ray techniques are not sufficiently sensitive ... the National Bureau of Standards, and examined ...

1972-10-01

368

Structure and morphology changes during nylon 66 fiber deformation via synchrotron x-ray scattering techniques  

Energy Technology Data Exchange (ETDEWEB)

Morphological and structural changes of nylon 66 were evaluated during a continuous heat-draw process. Results are discussed.

1996-12-31

369

Strong-interaction effect measurements in sigma hyperonic atoms of W and Pb  

Energy Technology Data Exchange (ETDEWEB)

Strong-interaction effects have been observed in the x-ray spectra of atoms formed with [Sigma][sup [minus

1993-03-01

370

Recent progress in energy-filtered high energy X-ray photoemission electron microscopy using a Wien filter type energy analyzer  

International Nuclear Information System (INIS)

Energy-filtered X-ray photoemission electron microscopy (EXPEEM) is a microscopy technique which has the potential to provide surface chemical mapping during surface chemical processes on the nanometer scale. We studied the possibilities of EXPEEM using a Wien filter type energy analyzer in the high energy X-ray region above 1000 eV. We have successfully observed the EXPEEM images of Au islands on a Ta sheet using Au 3d_5_/_2 and Ta 3d_5_/_2 photoelectron peaks which were excited by 2380 eV X-rays emitted from an undulator (BL2A) at Photon Factory. Our recent efforts to improve the sensitivity of the Wien filter energy analyzer will also be discussed.

2004-10-15

373

Radiation exposure to patients during hepatic interventional procedure  

International Nuclear Information System (INIS)

Objective: To investigate the X-ray radiation dose patients dealt with the hepatic intervention. Methods: Thermoluminescence and tissue-equivalent anthropomorphic phantom were used to measure the X-ray radiation dose in patients dealt with the hepatic intervention in 85 patients. Results: The peak skin dose in the patients who accepted hepatic intervention was from 179.95 to 1759.00 mGy, effective dose approached 29.22 mSv (male), 29.27 mSv (female). Conclusion: Hepatic intervention is now regarded as an important therapeutic method for liver cancer. However, the patients were exposed to too much X-ray radiation during interventional procedures. Some more effective protection should be taken to decrease the X-ray radiation dose accepted by patients. (authors)

2005-05-01

374

Pulse source of electron and X-ray radiations of subnanosecond duration  

International Nuclear Information System (INIS)

The time and dose characteristics of the electron and X-ray radiations of a tube, connected to a subnanosecond mega volt accelerator, are measured. By the pulse of the accelerating voltage of #>=# 600 kV with duration of #approx =# 0.3 ns the tube generates approximately 5 x 10"1"2 electrons pulse. The current amplitude equals approximately 5 kA/pulse and the radiation dose-about 5 kGy/pulse. The X-ray radiation dose from the tantalum external target constitutes 0.15 Gy/pulse. The prototypes of the electron and X-ray tubes sufficiently lower volumes, opening new applications in the technique and medicine, are developed

375

PRICES SUBJECT To CHq.G - NASA Technical Report Server (NTRS)  

Science.gov (United States)

by the radionuclide X-ray fluorescence analysis into several groups according to the atomic number of the determined element. Table I documents this. ...

376

On the Z-dependence of K#alpha#_1/K#beta#_1 X-ray intensity ratio  

International Nuclear Information System (INIS)

1976. Germany Ramaswamy, MK Birla Inst. of Tech. and Science, Pilani

1976-03-29

377

Measurements and calculations of M-shell X-ray production in Er, Yb and Lu by 0.75-6 MeV He ions  

Energy Technology Data Exchange (ETDEWEB)

M-shell X-ray production cross sections for the light rare-earth elements of {sup 68}Er, {sup 7}Yb and {sup 71}Lu have been measured for incident {sup 4}He{sup +} ions in the energy range from 0.75 to 6 MeV. The measured X-ray production cross sections are compared to the predictions of the First Born approximation, the ECPSSR theory and the ECUSAR theory. A comparison of the ytterbium M-shell X-ray production cross sections with these theories is made for two different sets of fluorescence yields and Coster-Kronig factors that are further modified for multiple ionization.

2005-12-15

378

Magnetospheric particle acceleration and X-ray emission of pulsars  

CERN Document Server

The available data on isolated X-ray pulsars, their wind nebulae, and the supernova remnants which are connected to some of these sources are analyzed. It is shown that electric fields of neutron stars tear off charged particles from the surface of neutron star and trigger the acceleration of particles. The charged particles are accelerated mainly in the field of magneto-dipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magneto-dipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.

2007-01-01

379

Luminescence and x-ray absorption measurements of persistent SrAl2O4:Eu,Dy powders: Evidence for valence state changes  

Science.gov (United States)

The development of new efficient afterglow phosphors is currently hampered by a limited understanding of the persistent luminescence mechanism. Radioluminescence (RL) and x-ray absorption measurements on the persistent phosphor SrAl2O4:Eu,Dy were combined to reveal possible valence state changes for the rare earth (co)dopants. Traps in the phosphor material are quickly filled when exposing thermally emptied SrAl2O4:Eu,Dy powder to x rays. On the same time scale a partial oxidation of Eu2+ to Eu3+ is observed by x-ray absorption near-edge spectroscopy (XANES), while for the trivalent dysprosium the valence state remains unchanged. The impact of these observations on the recently proposed models for persistent luminescence is discussed.

2011-08-01

380

Koji Mukai's Bibliography - Astrophysics Science Division Staff ...  

Science.gov (United States)

Jul 25, 2011 ... Koji Mukai's Bibliography. Invited Reviews. Mukai, K. 1994, "ASCA PV Phase Observations of Cataclysmic Variables," in "New Horizon of X-ray ...

381

K_#beta#/K_#alpha#X-ray intensity ratio in the region of 15#<=#Z#<=#22  

International Nuclear Information System (INIS)

The X-ray intensity ratio K_#beta#/K_#alpha# has been measured by using a 10 mCi "5"5Fe source (Mn K X-rays) and high resolution Si(Li) detector system coupled to a computer-controlled multichannel analyzer over the range of 15#<=#Z#<=#22. Correction have been made to the measured relative intensities (K_#alpha# and K_#beta# X-rays) for self-absorption in the sample, air, Be-window absorption and detection efficiency. The results are compared with those of other experiments and with the Scofield calculations. (author) 13 refs.; 3 figs.; 2 tabs.

1994-01-01

382

Ion-induced M X-ray emission from heavy lanthanides  

International Nuclear Information System (INIS)

Thick targets of several heavy lanthanide (Ho-Lu) compounds were bombarded by protons and "3He ions of 3 MeV/amu, and M_#alpha# and M_#beta# X-rays were measured with a crystal spectrometer. Ionization probabilities of the N-shell for zero impact parameter were obtained from the X-ray intensity ratio for proton and "3He ion impacts. A shell dependence of the ionization probability was found in a scaling plot. X-ray spectra of lanthanide compounds were compared and no chemical effect was observed. This result is considered to be due to the fact that the main component of M_#alpha# and M_#beta# lines is for radiative transition after the refilling of the 4f orbit (3d"-"14f"n"+"1 #-># 4f"n) where n denotes the number of 4f electrons of the target atom before ionization. (orig.).

1987-12-01

384

High-energy x-ray microscopy techniques for laser-fusion plasma research at the National Ignition Facility  

Energy Technology Data Exchange (ETDEWEB)

Multi-kilo-electron-volt x-ray microscopy will be an important laser-produced plasma diagnostic at future megajoule facilities such as the National Ignition Facility (NIF). However, laser energies and plasma characteristics imply that x-ray microscopy will be more challenging at NIF than at existing facilities. We use analytical estimates and numerical ray tracing to investigate several instrumentation options in detail, and we conclude that near-normal-incidence single spherical or toroidal crystals may offer the best general solution for high-energy x-ray microscopy at NIF and similar large facilities. Apertured Kirkpatrick{endash}Baez microscopes using multilayer mirrors may also be good options, particularly for applications requiring one-dimensional imaging over narrow fields of view. {copyright} 1998 Optical Society of America

1998-04-01

385

Future instrumentation for the study of the Warm-Hot Intergalactic Medium  

CERN Document Server

We briefly review capabilities and requirements for future instrumentation in UV- and X-ray astronomy that can contribute to advancing our understanding of the diffuse, highly ionised intergalactic medium.

2008-01-01

386

Feasibility analysis for attosecond X-ray pulses at FERMI@ELETTRA free electron laser  

Energy Technology Data Exchange (ETDEWEB)

We present preliminary analysis for the feasibility of the attosecond x-ray pulses at a proposed FERMI@ELETTRA free electron laser (FEL) [1]. In part 1 we restrict ourselves to minimal modifications to the proposed FEL and consider a scheme for attosecond x-ray production which can be qualified as a small add-on to a primary facility. We demonstrate that at 5-nm wavelength our scheme is capable for production of pulses with an approximate duration of 100 attoseconds at approximately 2 MW peak power and with an absolute temporal synchronization to a pump laser pulse. In part 2 we propose to use an FEL amplifier seeded by a VUV signal and to follow it by the scheme for attosecond x-ray production described in part 1.

2004-09-01

387

FUV and X-ray absorption in the Warm-Hot Intergalactic Medium  

CERN Document Server

The Warm-Hot Intergalactic Medium (WHIM) arises from shock-heated gas collapsing in large-scale filaments and probably harbours a substantial fraction of the baryons in the local Universe. Absorption-line measurements in the ultraviolet (UV) and in the X-ray band currently represent the best method to study the WHIM at low redshifts. We here describe the physical properties of the WHIM and the concepts behind WHIM absorption line measurements of H I and high ions such as O VI, O VII, and O VIII in the far-ultraviolet and X-ray band. We review results of recent WHIM absorption line studies carried out with UV and X-ray satellites such as FUSE, HST, Chandra, and XMM-Newton and discuss their implications for our knowledge of the WHIM.

2008-01-01

388

Electron-induced luminescence and x-ray spectrometer development  

Science.gov (United States)

Jan 22, 2011 ... dc.description.abstract, The progress in the development of a surface analysis tool based on the excitation of characteristic luminescence ...

389

Density Gradients for Isolation of Mononuclear Blood Cells for ...  

Science.gov (United States)

... to-continuum X-ray intensity ratio [5]. For ence in the means [7]. In addition, washing samples on thin films, the characteristic X- lymphocytes in NH ...

2011-05-15

392

Acceleration of particles in pulsar magnetosphere and the X-ray radiation  

CERN Document Server

The available data of single X-ray pulsars, their wind nebulae, and the SNRs which are connected to some of these sources are analysed. It is shown that electric field intensity of neutron stars tears off charged particles from the surface of neutron star and triggers the acceleration of particles. The charged particles are accelerated mainly in the field of magnetodipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magnetodipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.

2004-01-01

393

Using a photon phase-space source for convolution/superposition dose calculations in radiation therapy  

International Nuclear Information System (INIS)

For a given linac design, the dosimetric characteristics of a photon beam are determined uniquely by the energy and radial distributions of the electron beam striking the x-ray target. However, in the usual commissioning of a beam from measured data, a large number of variables can be independently tuned, making it difficult to derive a unique and self-consistent beam model. For example, the measured dosimetric penumbra in water may be attributed in various proportions to the lateral secondary electron range, the focal spot size and the transmission through the tips of a non-divergent collimator; the head-scatter component in the tails of the transverse profiles may not be easy to resolve from phantom scatter and head leakage; and the head-scatter tails corresponding to a certain extra-focal source model may not agree self-consistently with in-air output factors measured on the central axis. To reduce the number of adjustable variables in beam ...

2005-09-07

394

The mechanism of metal nanoparticle formation in plants: limits on accumulation  

Energy Technology Data Exchange (ETDEWEB)

Metal nanoparticles have many potential technological applications. Biological routes to the synthesis of these particles have been proposed including production by vascular plants, known as phytoextraction. While many studies have looked at metal uptake by plants, particularly with regard to phytoremediation and hyperaccumulation, few have distinguished between metal deposition and metal salt accumulation. This work describes the uptake of AgNO{sub 3}, Na{sub 3}Ag(S{sub 2}O{sub 3}){sub 2}, and Ag(NH{sub 3}){sub 2}NO{sub 3} solutions by hydroponically grown Brassica juncea and the quantitative measurement of the conversion of these salts to silver metal nanoparticles. Using X-ray absorption near edge spectroscopy (XANES) to determine the metal speciation within the plants, combined with atomic absorption spectroscopy (AAS) for total Ag, the quantity of reduction of Ag{sup I} to Ag{sup 0} is reported. Transmission electron microscopy (TEM) ...

2009-08-15

395

Synthesis of colloidal silver iron oxide nanoparticles--study of their optical and magnetic behavior.  

Science.gov (United States)

Silver iron oxide nanoparticles of fairly small size (average diameter approximately 1 nm) with narrow size distribution have been synthesized by the interaction of colloidal beta- Fe2O3 and silver nanoparticles. The surface morphology and size of these particles have been analyzed by using atomic force microscopy (AFM), field emission scanning electron microscopy (FESEM) and transmission electron microscopy (TEM). Their structural analysis has been carried out by employing x-ray diffraction (XRD), selected-area electron diffraction (SAED), optical and infrared (IR) spectroscopic techniques. The ageing of these particles exhibits the formation of self-assembly, possibly involving weak supramolecular interactions between Ag(I)O4 and Fe(III)O4 species. These particles display the onset of absorption in the near-infrared region and have higher absorption coefficient in the visible range compared to that of its precursors. Magnetic measurements ...

2009-07-01

396

Structural and electrical characteristics of epitaxial CoSi{sub 2} grown on n-Si{sub 0.83}Ge{sub 0.17}/n-Si(001) by reactive chemical vapor deposition using a Si capping layer  

Energy Technology Data Exchange (ETDEWEB)

Epitaxial cobalt disilicide (CoSi{sub 2}) layers are grown on n-Si{sub 0.83}Ge{sub 0.17}/n-Si(001) using a sacrificial Si capping layer at the growth temperature T{sub s}=650 deg. C by reactive chemical vapor deposition using cyclopentadienyl dicarbonyl cobalt (Co({eta}{sup 5}-C{sub 5}H{sub 5})(CO){sub 2}). Structural and electrical properties of epi-CoSi{sub 2}/Si{sub 0.83}Ge{sub 0.17}/Si(001) were measured by transmission electron microscopy, X-ray diffraction, Auger electron spectroscopy and sheet resistance measurement as a function of annealing temperature. The combined results showed that the epitaxial CoSi{sub 2} phase by the reaction of Co with the Si capping layer was formed in the as-grown layers. Rapid thermal anneals for the investigation of thermal stability of the as-grown layers showed good thermal stability of the epitaxial CoSi{sub 2} layers with the low sheet resistance value as low as congruent with 4.4 {omega}/cm up to the ...

2004-06-30

397

Structural and electrical characteristics of epitaxial CoSi_2 grown on n-Si_0_._8_3Ge_0_._1_7/n-Si(001) by reactive chemical vapor deposition using a Si capping layer  

International Nuclear Information System (INIS)

Epitaxial cobalt disilicide (CoSi_2) layers are grown on n-Si_0_._8_3Ge_0_._1_7/n-Si(001) using a sacrificial Si capping layer at the growth temperature T_s=650 deg. C by reactive chemical vapor deposition using cyclopentadienyl dicarbonyl cobalt (Co(#eta#"5-C_5H_5)(CO)_2). Structural and electrical properties of epi-CoSi_2/Si_0_._8_3Ge_0_._1_7/Si(001) were measured by transmission electron microscopy, X-ray diffraction, Auger electron spectroscopy and sheet resistance measurement as a function of annealing temperature. The combined results showed that the epitaxial CoSi_2 phase by the reaction of Co with the Si capping layer was formed in the as-grown layers. Rapid thermal anneals for the investigation of thermal stability of the as-grown layers showed good thermal stability of the epitaxial CoSi_2 layers with the low sheet resistance value as low as congruent with 4.4 #OMEGA#/cm up to the annealing temperature as high as 850 deg. C without ...

2004-06-30

398

Solid-state amorphization reaction in mechanically deformed Al_xHf_1_0_0_-_x multilayered composite powders and the effect of annealing  

International Nuclear Information System (INIS)

Single phase amorphous Al_xHf_1_0_0_-_x alloys with a wide amorphization range (33#<=#x#<=#75) were synthesized by the solid-state interdiffusion of pure polycrystalline Al and Hf powders at room temperature using a rod-milling technique. The mechanisms of metallic glass formation and competing crystallization processes in the mechanically deformed composite powders were investigated by means of X-ray diffraction, differential thermal analysis, scanning electron microscopy and transmission electron microscopy. The numerous intimate layered composite particles of the diffusion couples that formed during the first and intermediate stages of milling (0-173 ks) are intermixed to form amorphous phase(s) upon heating to about 980 K by so-called thermally assisted solid-state amorphization (TASSA). The amorphization heat formation for the binary Al_xHf_1_0_0_-_x system via TASSA, #DELTA#H"T"A"S"S"A_a, was measured directly as a function of the ...

1999-03-04

399

Shape control of CeO{sub 2} nano-particles and synthesis of nano-metric solid acid SO{sub 4}{sup 2-}/CeO{sub 2}  

Energy Technology Data Exchange (ETDEWEB)

Nano-particles of CeO{sub 2} with the smallest average particle size (18.7 nm) and spherical morphology were obtained from a mixture solution of Ce(NO{sub 3}){sub 3}{center_dot}6H{sub 2}O, citric acid, polyvinyl alcohol by an auto-combustion process exploiting sol-gel as precursors. The course of size control and shape control by polyvinyl alcohol was examined in detail. A transmission electron microscopy (TEM) and an atomic force microscopy (AFM) were employed to characterize the particle-size and morphology of CeO{sub 2} particles. In addition, a sort of nano-metric solid acid SO{sub 4}{sup 2-}/CeO{sub 2} based on CeO{sub 2} nano-particles was prepared by macerating, filtering, drying and calcining processes. The particle-size of SO{sub 4}{sup 2-}/CeO{sub 2} was also assessed by TEM. The composition of SO{sub 4}{sup 2-}/CeO{sub 2} was analyzed by X-ray diffraction (XRD) and infrared spectra (IR). The influencing factors in the formation of ...

2003-12-20

400

Radiation 2006. In association with the Polymer Division, Royal Australian Chemical Institute. Incorporating the 21st AINSE Radiation Chemistry Conference and the 18th Radiation Biology Conference, conference handbook  

International Nuclear Information System (INIS)

Full text: The general population is daily exposed to chronic, low doses of ionizing radiation (IR) from both natural and artificial sources. The biological consequences of acute, high dose IR exposure can be readily determined; however, the nature and significance of low dose, low dose-rate IR effects are still the subject of debate. Confounding the issue, are the phenomena collectively referred to as the Radiation-induced Bystander Effect (RIBE). The RIBE describes a collection of in vitro observations that suggest the presence of a soluble, transmissible factor(s) released from irradiated cells that can induce a biological response in un-irradiated cells. The induction, nature and magnitude of the RIBE varies between cell culture systems, radiation sources and end-points measured. Efforts to confirm the presence of the RIBE in vivo have been confined to in vivo-like culture systems and limited work with tumour and bone-marrow transplantation models. Validation ...

2006-01-01

401

Properties of dust particles sampled from windboxes of an iron ore sintering plant: Surface structures of unburned carbon  

Energy Technology Data Exchange (ETDEWEB)

Aiming to understand the formation mechanism of dioxins in the iron ore sintering process, dust samples obtained from some windboxes of a commercial iron ore sintering plant have been characterized with a powder X-ray diffraction (XRD), by the transmission electron microscope (TEM) equipped with an electron energy loss spectroscopy (EELS), and by the temperature-programmed desorption (TPD) and temperature-programmed oxidation (TPO) techniques. The elemental and XRD analyses reveal that the content of the Cl present in the samples ranges from 0.075 mass%-dry to 5.1 mass%-dry and tends to be higher at smaller dust particles, and that some of the Cl exists as KCl with the average crystalline size between 40 nm and 50 nm. Dust samples also contain a significant amount of unburned carbon, and the smallest dust particles, < 500 {mu}m, show the highest C contents in many cases and consist partly of C, K, and Cl elements. The TPD and TPO ...

2006-07-01

402

Processing of La/sub 1. 8/Sr/sub 0. 2/CuO/sub 4/ and YBa/sub 2/Cu/sub 3/O/sub 7/ superconducting thin films by dual-ion-beam sputtering  

Science.gov (United States)

High quality La/sub 1.8/Sr/sub 0.2/CuO/sub 4/ and YBa/sub 2/Cu/sub 3/O/sub 7/ superconducting thin films, with zero resistance at 88 K, have been made by dual-ion-beam sputtering of metal and oxide targets at elevated temperatures. The films are about 1.0 ..mu..m thick and are single phase after annealing. The substrates investigated are Nd-YAP, MgO, SrF/sub 2/, Si, CaF/sub 2/, ZrO/sub 2/-9% Y/sub 2/O/sub 3/, BaF/sub 2/, Al/sub 2/O/sub 3/, and SrTiO/sub 3/. Characterization of the films was carried out using Rutherford backscattering spectroscopy, resistivity measurements, transmission electron microscopy, x-ray diffraction, and secondary ion mass spectroscopy. Substrate/film interaction was observed in every case. This generally involves diffusion of the substrate into the film, which is accompanied by, for example, the replacement of Ba by Sr in the YBa/sub 2/Cu/sub 2/O/sub 7/ structure, in the case of SrTiO/sub 3/ substrate. The best ...

1988-03-15

403

Physical and electrochemical characterization of CdS hollow microspheres prepared by a novel template free solution phase method  

International Nuclear Information System (INIS)

Novel CdS hollow microspheres have been successfully synthesized via a facile template-free solution-phase reaction from cadmium nitrate and thioacetamide precursors. The morphology of CdS hollow microspheres depends strongly on the ratio between the precursors, cadmium nitrate to thioacetamide ratio. The physical properties of the hollow microspheres have systematically been studied by different characterization methods. The stoichiometry of the hollow microspheres studied by the energy dispersive X-ray diffraction spectroscopy confirmed that the synthesized CdS hollow microspheres are nearly stoichiometric bulk like CdS. The morphology of the hollow microspheres studied by high resolution scanning electron microscopy and transmission electron microscopy observations showed that the CdS hollow microspheres of the size of 2.5 ?m have hollow structure and are constructed by several nanoparticles of the size between 30 and 40 nm. The UV-visible ...

2010-12-15

404

Photooxidation of different organic dyes (RB, MO, TB, and BG) using Fe(III)-doped TiO{sub 2} nanophotocatalyst prepared by novel chemical method  

Energy Technology Data Exchange (ETDEWEB)

The nano-structured Fe(III)-doped TiO{sub 2} photocatalysts with anatase phase have been developed for the oxidation of non-biodegradable different organic dyes like methyl orange (MO), rhodamine B (RB), thymol blue (TB) and bromocresol green (BG) using UV-Hg-lamp. The different compositions of Fe{sub x}Ti{sub 1-x}O{sub 2} (x = 0.005, 0.01, 0.05, and 0.1) nanocatalysts synthesized by chemical method (CM), have been characterized by X-ray diffraction (XRD), UV-vis diffuse reflectance spectra, specific surface area (BET), transmission electronic microscopy (TEM) analysis, XPS, ESR and zeta potential. From XRD analysis, the results indicate that all the compositions of Fe(III) doped in TiO{sub 2} catalysts gives only anatase phase not rutile phase. For complete degradation of all the solutions of the dyes (MO, RB, TB, and BG), the composition with x = 0.005 is more photoactive compared all other compositions of Fe{sub x}Ti{sub 1-x}O{sub 2}, and ...

2008-09-15

405

Performance improvement of pasted nickel electrodes with an addition of ball-milled nickel hydroxide powder  

Energy Technology Data Exchange (ETDEWEB)

Spherical {beta}-Ni(OH){sub 2} was modified by a low-cost method of normal ball milling (NBM), and the physical properties of both ball-milled and un-milled Ni(OH){sub 2} were characterized by transmission electron microscopy, specific surface area, particle size distribution and X-ray diffraction. It was found that NBM could obviously increase the surface area, decrease the particle and crystallite size, and reduce the crystallinity of {beta}-Ni(OH){sub 2}, which were advantageous to the improvement of the electrochemical activity of Ni(OH){sub 2}. NBM also lowered the packing density and flowability of Ni(OH){sub 2}, as revealed by the measurements of tapping density and angle of repose. Electrochemical performances of pasted nickel electrodes with an addition of ball-milled Ni(OH){sub 2} to spherical Ni(OH){sub 2} as the active material were investigated, and were compared with those of the pure spherical Ni(OH){sub 2} electrodes. ...

2006-09-15

406

Intrinsic magnetism in Fe doped SnO2 nanoparticles  

International Nuclear Information System (INIS)

Iron doped semiconducting nanoparticles Sn1-xFexO2 with x=0, 0.001, 0.002, 0.003, 0.004, 0.01 and 0.03 were prepared by a sol-gel method. The X-ray diffraction, Transmission Electron Microscopy measurements confirm the rutile structure with no impurity phase. The three characteristic lines of electron spin resonance (ESR) are observed in the doped samples for all compositions, which is a clear evidence for rhombic Fe3+ in rutile phase. The line width of ESR increases with increase in Fe concentration due to induced disorder. The spin-pumping effect is observed at temperatures below 250 K for the samples with x=0.01 and 0.03. However, based on the Curie-Weiss susceptibility, iron is in paramagnetic state and is subject to weak antiferromagnetic interaction. Blue shift in the optical band gap is observed with increase in the Fe content. -- Graphical abstract: The ESR spectra reveal that the nature of Fe in Sn1-xFexO2 samples is isolated rhombic ...

2011-01-01

407

Identifying surface structural changes in layered Li-excess nickel manganese oxides in high voltage lithium ion batteries: A joint experimental and theoretical study  

Energy Technology Data Exchange (ETDEWEB)

High voltage cathode materials Li-excess layered oxide compounds Li[Ni{sub x}Li{sub 1/3-2x/3}Mn{sub 2/3-x/3}]O{sub 2} (0 < x < 1/2) are investigated in a joint study combining both computational and experimental methods. The bulk and surface structures of pristine and cycled samples of Li[Ni{sub 1/5}Li{sub 1/5}Mn{sub 3/5}]O{sub 2} are characterized by synchrotron X-Ray diffraction together with aberration corrected Scanning Transmission Electron Microscopy (a-S/TEM). Electron Energy Loss Spectroscopy (EELS) is carried out to investigate the surface changes of the samples before/after electrochemical cycling. Combining first principles computational investigation with our experimental observations, a detailed lithium de-intercalation mechanism is proposed for this family of Li-excess layered oxides. The most striking characteristics in these high voltage high energy density cathode materials are (1) formation of tetrahedral lithium ...

2011-09-06

408

Enhanced corrosion resistance by sol-gel-based ZrO_2-CeO_2 coatings on magnesium alloys  

International Nuclear Information System (INIS)

The physical, chemical and mechanical properties of magnesium alloys make them attractive materials for automotive and aerospace applications. However, these materials are susceptible to corrosion and wear. This work discusses the potential of using sol-gel based coatings consisting of ZrO_2 and 15 wt.% of CeO_2. The CeO_2 component provides enhanced corrosion protection, while ZrO_2 impart corrosion as well as wear resistance. Coating deposition was performed by the dip coating technique on two magnesium alloy substrates with different surface finishes: AZ91D (as-casted, sand-blasted, and machined) and AZ31 (rolled and machined). All as-deposited coatings (xerogel coatings) were then subjected to 10 h annealing: a temperature of 180 C was applied to the AZ91D alloy and 140 C to the AZ31 alloy. Morphological and structural properties of the annealed coatings were investigated by scanning electron microscopy, atomic force microscopy and transmission electron ...

2005-02-01

409

Effect of thermal treatments on the properties of nickel and cobalt activated-charcoal-supported catalysts  

Energy Technology Data Exchange (ETDEWEB)

The effect of thermal pretreatment in N[sub 2] up to 723 K and the activation treatments in H[sub 2] and an inert atmosphere on the properties of Ni and Co activated-charcoal-supported catalysts were studied. Catalysts were characterized by means of N[sub 2] adsorption at 77 K, H[sub 2] chemisorption at room temperature, thermogravimetric analysis (TGA), X-ray diffraction (XRD), and transmission electron microscopy (TEM). The catalysts' activity and selectivity for acetone hydrogenation to 2-propanol under unusual and severe conditions (473 K and high overall acetone conversion) were also measured. TGA and XRD evidence was found for the charcoal-support-promoted NiO and CoO reduction to the metallic states when the catalysts were subjected to an inert atmosphere above 723 K caused a loss of acetone hydrogenation activity (calculated on a metal load basis) for both the Ni and Co activated-charcoal-supported catalysts, with respect to ...

1994-02-01

410

Analysis of degradation in nickel-based alloys using focused ion beam imaging and specimen preparation combined with analytical electron microscopy  

International Nuclear Information System (INIS)

Focused ion beam (FIB) microscopes have become well-established in the semiconductor industry during the past decade, and are rapidly gaining attention in the field of materials science, both as a tool for producing site specific, parallel sided transmission electron microscope (TEM) specimens and as stand alone specimen preparation and imaging systems. FIB secondary electron imaging (SEI) of nickel-based alloys, such as commercially produced Alloy 600 (approximately Ni 15Cr 10Fe 0.5C), has been demonstrated to show a high degree of sensitivity to the presence of deformation in the alloy, and FIB secondary ion imaging (SII) is particularly useful for identifying the presence of grain boundary corrosion, as secondary ion yields from metallic specimens can increase by three orders of magnitude in the presence of oxygen. This 'oxygen enhanced yield', makes FIB SII ideal for detection of corrosion at grain boundaries down to thicknesses of only a few tens of ...

2002-09-23

411

XRF and PIXE method as trols for the element analysis of metallic glasses  

International Nuclear Information System (INIS)

The radionuclide X-ray fluorescence and particle induced X-ray emission methods were used for rapid and nondestructive analysis of metallic glasses. The methods were compared for accuracy and precision with the atomic absorption method. Some results of the analyses of Fe_xNi_8_0_-_xB_2_0 materials are briefly reviewed. The distribution of elements along the width as well as the length and a qualitative analysis of the composition of material surfaces are considered. (author).

1986-01-01

412

XRF and PIXE analysis of metallic glasses  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence and particle induced X-ray emission methods were used for a rapid and nondestructive analysis of metallic glasses. The methods are compared in accuracy and precision with the atomic absorption method. Some results of analyses of Fe_xNi_8_0_-_xB_2_0 materials are briefly reviewed. The distribution of elements along the width and length, and a qualitative analysis of the composition of material surfaces are considered. (author) 3 refs.

1987-05-01

413

X-ray spectral microanalysis of component redistribution in finely dispersed two-phase alloys  

International Nuclear Information System (INIS)

It is shown that it is necessary to take into account locality of the analysis and to introduce additional corrections for partial capture of matrix and fluorescent subexcitation by matrix during quantitative X-ray spectral microanalysis of finely dispersed materials. Cast two-phase (#alpha#+#beta#) titanium alloy VT3-1 is chosen as an investigation object.

414

X-ray generation by the Smith-Purcell effect  

International Nuclear Information System (INIS)

Smith-Purcell (S-P) radiation is produced when electrons graze the surface of a grating. Calculations based on the theory of diffraction radiation show that, given severe restrictions on e"--beam quality, S-P radiation is highly efficient. Efficient S-P x-ray generation requires relativistic e"- beams having a transverse momentum and dimension whose product approaches the Heisenberg uncertainty limit.

415

X-ray diffraction studies of palladium silicide thin films  

Energy Technology Data Exchange (ETDEWEB)

The solid state reaction between a Pd thin film and a Si substrate produces a single new phase, Pd/sub 2/Si, for temperatures <700/sup 0/C. When the substrate is a single crystal of (111) surface orientation, this process is particularly interesting because the silicide grows epitaxially. Growth of epitaxial interfacial Pd/sub 2/Si was the focus of this study using X-ray diffraction techniques.

1985-01-01

416

X-RAY MICROANALYSIS OF A RADIOACTIVE PARTICLE WITH THE AID OF THE ELECTRON MICROSCOPE  

Science.gov (United States)

A radioactive particle was analyzed to discover the composition of the inactive material of the particle. The method uses the x-ray line spectrum of the K series caused by electron irradiation of the particle in the electron microscope. Iron and aluminum or silicon (the last two could not be distinguished) were found as inactive components in the particle. (D.L.C.)

1962-07-28

417

Survey of radiation doses to patients from the diagnostic use of X-rays  

International Nuclear Information System (INIS)

The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).

1977-06-01

418

Structure analysis of ferrite in deformed pearlitic steel by means of X-ray diffraction method with synchrotron radiation  

Energy Technology Data Exchange (ETDEWEB)

Structure of ferrite in drawn pearlitic steel containing 0.9 mass% C was investigated with X-ray diffraction technique using synchrotron radiation. In the detailed analysis of diffraction peaks of ferrite during the drawing process, it was experimentally revealed that the transformation of ferrite from bcc to bct due to the supersaturation of carbon in ferrite of heavily drawn pearlitic steel.

2004-07-15

419

Structure analysis of ferrite in deformed pearlitic steel by means of X-ray diffraction method with synchrotron radiation  

International Nuclear Information System (INIS)

Structure of ferrite in drawn pearlitic steel containing 0.9 mass% C was investigated with X-ray diffraction technique using synchrotron radiation. In the detailed analysis of diffraction peaks of ferrite during the drawing process, it was experimentally revealed that the transformation of ferrite from bcc to bct due to the supersaturation of carbon in ferrite of heavily drawn pearlitic steel.

2004-07-01

420

Structural intermediates in the assembly of taxoid-induced microtubules and GDP-tubulin double rings: time-resolved X-ray scattering.  

UK PubMed Central (United Kingdom)

We have studied the self-association reactions of purified GDP-liganded tubulin into double rings and taxoid-induced microtubules, employing synchrotron time-resolved x-ray solution scattering. The...Full Text Available

1996-05-01

421

Soft X-ray spectra of amorphous hydrogenated silicon  

Energy Technology Data Exchange (ETDEWEB)

The Si-L X-ray emission spectrum of amorphous hydrogenated silicon (a-Si:H) is presented and discussed. For a qualitative interpretation of the measured spectra cluster calculations of pure Si clusters (SiSi4) and Si clusters with hydrogen (SiSi3H) have been performed using a simplified LCAO-X scheme. In general the level shifts caused by introduction of hydrogen are small compared with the valence band width.

1985-06-01

422

Radionuclide X-ray fluorescence determination of Mn, Fe, Cu, Zn and Pb in wastewaters and sludges from wastewater treatment plants in Bratislava (SR)  

International Nuclear Information System (INIS)

Radiometric X-ray fluorescence analysis was used for the determination of Mn, Fe, Cu, Zn and Pb in wastewater and sludges from three wastewater treatment plants in Bratislava (SR). Metals were determined in wastewaters after preconcentration by 8-hydroxyquinoline and in sludges by drying and pressing to pellets. "2"3"8Pu and "1"0"9Cd was used for excitation of fluorescence radiation. (author).

1997-01-01

423

Radionuclide X-ray fluorescence determination of Cr, Fe, Cu, Zn,and Pb in industrial wastewaters after preconcentration of determined elements  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis was used for the determination of Cr, Fe, Cu, Zn and Ph in industrial wastewaters (from surface treatment of metals and glasses) after precipitation of determined elements by 8-hydroxyquinoline. (author).

1997-01-01

424

Radionuclide X-ray fluorescence analysis of solid aerosol particles on Synpor 4 collection filters  

International Nuclear Information System (INIS)

The feasibility was studied of the application of radionuclide X-ray fluorescence analysis to the identification and determination of chemical elements in the air. A description of the method is presented, the main stages of the analysis are discussed (sample preparation and standards, selection of radioactive radiation sources, geometry of measurement and evaluation of results). The method is illustrated on the determination of elements Fe, Cu, Zn, Br, and Pb in air samples taken in the city of Prague. (author) 2 tabs., 2 figs., 14 refs.

1992-01-01

425

Radiation exposure of the population of the GDR by X-ray diagnostics  

International Nuclear Information System (INIS)

The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.

1986-01-01

426

M shell x-ray emission in Pb, Th and U due to L_3 to M sub shell transfer of vacancies  

International Nuclear Information System (INIS)

M shell x-ray production cross sections in thick targets of Pb, Th and U by K x-rays of Rb, Nb and Mo respectively have been measured. As the incident K x-ray energies are above the L_3 edge but below L_2 edge energies of the respective target elements under reference, the M x-rays are produced not only due to direct interaction of incident photons with M shell electrons but also due to the shift of the L_3 subshell vacancies to the M shell. The experiment has been performed using a double reflection geometrical setup with a 1 Curie"2"4"1Am gamma ray source and a Si (Li) x-ray spectrometer. The measured values have been compared with those calculated using known values of M and L_3 subshell photoionisation cross sections and fluorescence yields etc., wherever possible. The component of the percentage contribution due to shift of L_3 subshell vacancies to M shell to the total M shell ...

427

K_#beta#/K_#alpha# X-Ray Intensity Ratio Studies on the Valence Electronic States of 3d-Transition Metals in some of their Compounds  

International Nuclear Information System (INIS)

Our studies on K#beta#/K#alpha# X-ray intensity ratios of some of the technologically important 3d-transition metal compounds have been reviewed. Comparison of the experimental results with single-configuration Dirac-Fock calculations provided important information on the valence states of the transition metals in various compounds, which can be helpful in understanding the nature of bonding in the compounds. (author)

2000-02-01

428

Is the Ksub(#beta#)/Ksub(#alpha#) X-ray intensity ratio dependent upon the energy of an inducing proton  

International Nuclear Information System (INIS)

Ksub(#beta#)/Ksub(#alpha#) X-ray intensity ratios have been measured for various elements between Z = 29 and Z = 79 for incident proton energies of 23.6, 32.1 and 43.6 MeV. The results yield no evidence for a variation in ratio with particle energy. (orig.).

1980-01-01

429

Improving airport explosives detection  

Energy Technology Data Exchange (ETDEWEB)

ORNL has developed the technology to detect hidden explosives in luggage using X ray and neutron detection devices. The Federal Aviation Administration has ordered the airlines to buy and install Thermal Neutron Analysis (TNA) units. The combined pulsed-neutron and X-ray interrogation inspection (CPNX) system developed at ORNL uses less radioactive materials as well as being more sensitive to weapons, electronic devices and plastic explosives.

1990-01-01

430

Heavy metals in industrial wastewater determined by radionuclide x-ray fluorescence analysis and their effects on Allium cepa root tip cells  

International Nuclear Information System (INIS)

Radionuclide x-ray fluorescence method was used in the determination of Cr, Ni and other heavy metals content in wastewater of an engineering plant taken both before and after chemical treatment. Toxic effects of the wastewaters using Allium cepa root tip cells were tested. (author) 8 refs.; 2 tabs.

1994-05-01

431

Heavy metals and some other elements in medicinal plants. Determined by X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Determination of Mn, Fe, Cu, Zn, Hg, Pb, Br, Se, Rb, Sr and Cd in the medicinal plants by radionuclide X-ray fluorescence analysis (using "2"3"8Pu, "2"4"1Am/Ag and "1"2"5I) is described. (author). 12 refs., 2 tabs.

1995-01-01

432

Heavy element contamination of surface waters in the region Banska Stiavnica (SR) measured by radionuclide X/ray fluorescence analysis  

International Nuclear Information System (INIS)

Heavy metals (Pb, Cd, Mn, Cu, Zn, Fe) were determined in surface waters in the surroundings of the depositories of the mining shrubs in the region of Banska Stiavnica (SR) by radionuclide X-ray fluorescence analysis. Allowed concentrations of the determined metals are exceeded numerously (multiplicity in some cases was 10"3-10"6). (author).

1997-01-01

433

FLASH-the first soft x-ray free electron laser (FEL) user facility  

Energy Technology Data Exchange (ETDEWEB)

The free electron laser (FEL) FLASH at DESY in Hamburg is the first x-ray FEL ever built. Many new developments were necessary in order to exploit the unique properties of this novel light source for scientific experiments. The facility has constantly been improved and several major upgrades have been made or are currently underway. This paper reviews the main characteristics of the user facility as well as the major developments and upgrades.

2010-10-14

434

Determination of cesium and selenium in cultivated mushrooms using radionuclide X-ray fluorescence technique  

International Nuclear Information System (INIS)

Cesium and selenium intake of cultivated mushrooms (Agaricus bisporus), with these elements previously added to culture medium, has been examined from the viewpoint of health- and environmental protection. The process of measuring has been carried out by the radionuclide X-ray fluorescence technique. Treatments of the elementary substance with Se salt appears to influence the Se content of the mushrooms to a significant extent. Cs intake is of considerable importance, as this element is accumulated by mushrooms. (author)

2000-09-01

435

Determination of Y, Ba and Cu in superconductor films by x-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide x-ray fluorescence analysis was used for the determination of Y, Ba and Cu in thin high-temperature superconducting films. Atomic emission ICP spectrometry was used to estimate the precision and accuracy of analytical results. Reasonable agreement between both methods was obtained when a polynomial calibration curve was applied. (author) 4 refs.; 4 tabs.

1994-06-01

436

Determination of Mn, Fe, Ni, Cu, Zn and Pb contents in samples of apple trees by radionuclide X-ray fluorescence analysis  

Energy Technology Data Exchange (ETDEWEB)

The applicability of the radionuclide X-ray fluorescence analysis (RXFA) for qualitative and quantitative evaluation of environmental plant samples is discussed and examples of determination of Mn, Fe, Ni, Cu, Zn, Pb in samples of apple trees are given. The instrumentation, the standard and sample preparation are also presented.

1982-12-01

437

Determination of Fe and Zn in healing plants by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence method was used for the determination of Fe and Zn in healing plants (Sage, Peppermint, Stinging, Common Agrimony, Milfoil, Ribwort, Tansy, White Dead-Nettle). "2"3"8Pu exciting source and Si/Li semiconductor detector were used for the determination. (author)

1999-06-01

438

Determination of Fe and Zn in agricultural plants with special cultivation by radionuclide x-ray fluorescence analysis  

International Nuclear Information System (INIS)

Fe and Zn were determined in various parts of maize (Zea mays) in dependence on quantity of organic substrate EKOFERT as organic fertilizer in soil, using radionuclide X-ray fluorescence analysis. The increase of quantity of organic substrate EKOFERT in soil causes a decrease of heavy metal concentrations in certain parts of the plant. (author). 4 refs., 1 tab.

1996-01-01

439

Determination of Cu, Ni, Zn and Pb contents in taraxacum officinale near the highway D-61 Bratislava-Trnava (SR) by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence method with Si/Li semiconductor detector and "2"3"8Pu exciting source was used for the determination of Cu, Ni, Zn and Pb in plant samples (Taraxacum officinale) from various localities near the highway D-61 Bratislava-Trnava (SR). (author) 2 refs.; 1 fig.; 1 tab.

1993-12-01

440

Determination of Cu, Ni, Zn and Pb contents in soil near the D-61 Bratislava-Trnava Highway by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence method with Si/Li semiconductor detector and "2"3"8Pu exciting source was used for the determination of Cu, Ni, Pb, and Zn in soil samples from various localities near the D-61 Bratislava-Trnava highway (CSFR). (author) 1 ref.; 1 tab.

1993-01-01

441

Comments on possible preferential order-disorder in A-15 compounds based upon Nb  

International Nuclear Information System (INIS)

The possible existence of preferential B-site disorder in A-15 compounds recently claimed on the basis of x-ray powder diffraction data but questioned from the viewpoint of known phase diagrams is examined for some Nb-based compounds of this type. It is concluded that x-ray powder data do not allow the determination of both order and compositional variables as suggested, and the latter must therefore be determined by some other method. (author).

442

Chemical sensitivity of the Ksub(. beta. )/Ksub(. cap alpha. ) x-ray intensity ratio for 3d elements  

Energy Technology Data Exchange (ETDEWEB)

Chemical influences on the relative Ksub(..beta..)/Ksub(..cap alpha..) x-ray intensity ratio up to five per cent were found for different chemical constitutions of Cr, Mn, Fe and Cu by very precise PIXE measurements. In the discussion of these effects, screening of 3p electrons by a varying 3d valence charge, as well as polarizational effects are of importance.

1982-12-28

443

Chemical sensitivity of the Ksub(#nu#)/Ksub(#alpha#) x-ray intensity ratio for 3d elements  

International Nuclear Information System (INIS)

Chemical influences on the relative Ksub(#nu#)/Ksub(#alpha#) x-ray intensity ratio up to five per cent were found for different chemical constitutions of Cr, Mn, Fe and Cu by very precise PIXE measurements. In the discussion of these effects, screening of 3p electrons by a varying 3d valence charge, as well as polarisational effects are of importance. (author).

1982-12-01

444

Changes in the profile structure of the sarcoplasmic reticulum membrane induced by phosphorylation of the Ca2+ ATPase enzyme in the presence of terbium: a time-resolved x-ray diffraction study.  

UK PubMed Central (United Kingdom)

The design of the time-resolved x-ray diffraction experiments reported in this and an accompanying paper was based on direct measurements of enzyme phosphorylation using [gamma-32P]ATP that were employed...Full Text Available

1994-05-01

445

Calculated valence electronic structure of 3d metals for use in the X-ray intensity ratio studies  

Energy Technology Data Exchange (ETDEWEB)

3d occupation numbers of the transition elements corresponding to various types of atomic configurations are calculated by means of the linear muffin-tin orbital (LMTO) method. This data is used with the multiconfiguration Dirac-Fock (MCDF) X-ray intensity ratios to estimate the electron populations of the 3d metals in alloys.

2010-09-15

446

Calculated valence electronic structure of 3d metals for use in the X-ray intensity ratio studies  

International Nuclear Information System (INIS)

3d occupation numbers of the transition elements corresponding to various types of atomic configurations are calculated by means of the linear muffin-tin orbital (LMTO) method. This data is used with the multiconfiguration Dirac-Fock (MCDF) X-ray intensity ratios to estimate the electron populations of the 3d metals in alloys.

2010-09-01

447

Analysis of titanium and zirconium in red mud with energy dispersive x-ray spectrometry  

Energy Technology Data Exchange (ETDEWEB)

An energy dispersive x-ray fluorescence technique was used for the determination of Titanium (Ti) and Zirconium (Zr) in red mud by using a standard addition method. An annular {sup 241}Am source is employed for excitation of K shells of elements. 13 refs., 2 figs., 1 tab.

1996-11-01

448

Analysis of high-temperature superconducting films by x-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis was used for the determination of Cu, Y and Ba in very thin high-temperature superconducting films. The precision of the method is better than 3% for about 1 #mu#m thick films. The atomic emission ICP spectrometry was used to testify results of XRF analysis. An acceptable agreement of both methods was obtained. (author) 4 refs.; 2 tabs.

1991-09-01

449

A sample preparation for quantitative determination of magnesium in individual lymphocytes by electron probe X-ray microanalysis.  

Science.gov (United States)

We present a sample preparation method for measuring magnesium in individual whole lymphocytes by electron probe X-ray microanalysis. We use Burkitt's lymphoma cells in culture as the test sample and compare X-ray microanalysis of individual cells with atomic absorption analysis of pooled cell populations. We determine the magnesium peak-to-local continuum X-ray intensity ratio by electron probe X-ray microanalysis and calculate a mean cell magnesium concentration of 39 +/- 19 mmol/kg dry weight from analysis of 100 cells. We determine a mean cell magnesium concentration of 34 +/- 4 mmol/kg dry weight by atomic absorption analysis of pooled cells in three cell cultures. The mean cell magnesium concentrations determined by the two methods are not significantly different. We find a 10% coefficient of variation for both methods of analysis and a 30% coefficient of variation in magnesium concentration among ...

1986-01-01

450

A radiant temperature numerical method for laser-plasma diagnostic using SXRSC with absorption method  

International Nuclear Information System (INIS)

An numerical method was developed for measuring radiant temperature using a set of absorption-foils coupled to soft x ray streak camera, SXRSC, in laser plasma experiments. An numerical code, SCC, was given. An x-ray intensity ratio vs temperature was calculated for Parylene, C_3H_6, Mylar and Aluminium. A suitable range of the measuring temperature was discussed to some absorber.

1990-01-01

451

7. Overview of radionuclide X-ray fluorescence analysis of components of the environment  

International Nuclear Information System (INIS)

A survey is presented of studies dealing with radionuclide X-ray fluorescence analysis (RXFA) of impurities in the air, water, soil, sediments and biological materials, mainly blood, urine, hair, soft tissues and bones. Tabulated are lists of published works on RXFA of the air, water and biological materials. (ES).

1983-12-01

452

X-ray scattering signatures of {beta}-thalassemia  

Energy Technology Data Exchange (ETDEWEB)

X-ray scattering from lyophilized proteins or protein-rich samples is characterized by the presence of two characteristic broad peaks at scattering angles equivalent to momentum transfer values of 0.27 and 0.6 nm{sup -1}, respectively. These peaks arise from the interference of coherently scattered photons. Once the conformation of a protein is changed, these two peaks reflect such change with considerable sensitivity. The present work examines the possibility of characterizing the most common cause of hemolytic anaemia in Egypt and many Mediterranean countries; {beta}-thalassemia, from its X-ray scattering profile. This disease emerges from a genetic defect causing reduced rate in the synthesis of one of the globin chains that make up hemoglobin. As a result, structurally abnormal hemoglobin molecules are formed. In order to detect such molecular disorder, hemoglobin samples of {beta}-thalassemia patients are collected, lyophilized and ...

2009-08-11

453

X-ray and HeI 1.0830 mu emission from protostellar jets  

CERN Document Server

Context. The high energies of protostellar jets, implied by recent observations of X-rays from such flows, came very much as a surprise. Inferred shock velocities are considerably higher than what was previously known, hence putting even larger energy demands on the driving sources of the jets. The statistics of X-ray emitting jets are still poor, yet a few cases exist which seem to imply a correlation between the presence of HeI 1.0830 mu emission and X-ray radiation in a given source. Aims. This tentative correlation needs confirmation and explanation. If the jet regions of HeI 1.0830 mu emission are closely associated with those producing X-rays, high resolution infared spectroscopy can be used to observationally study the velocity fields in the hot plasma regions of the jets. This would provide the necessary evidence to test and further develop theoretical models of intermediately fast (> 500 - ...

2006-01-01

454

The infrared-dominated jet of 3C401  

CERN Document Server

We present a Hubble Space Telescope image of the FRII radio galaxy 3C 401, obtained at 1.6 microns with the NICMOS camera in which we identify the infrared counterpart of the brightest region of the radio jet. The jet has a complex radio structure and brightens where bending occurs, most likely as a result of relativistic beaming. We analyze archival data in the radio, optical and X-ray bands and we derive its spectral energy distribution. Differently from all of the previously known optical extragalactic jets, the jet in 3C401 is not detected in the X-rays even in a long 48ksec X-ray Chandra exposure and the infrared emission dominates the overall SED. We propose that the dominant radiation mechanism of this jet is synchrotron. The low X-ray emission is then caused by two different effects: i) the lack of any strong external photon field and ii) the shape of the electron distribution. This affects the ...

2005-01-01

455

Spherically bent crystal spectroscopy in laser-produced plasma  

International Nuclear Information System (INIS)

A curved crystal X-ray spectrographs of reflection type spherical geometry was required based on the Johann scheme. Due to their high efficiency and resolution, X-ray spectrographs of focusing spectrograph spatial resolution are suitable for detecting weak X-ray spectra in spectrometers for laser fusion research. Spherically bent mica crystal with a radius of curvature of 380 mm was used in the spectrometer. The Bragg angle of the crystal analyzer was 51 degree. The image plate was employed to obtain high spatial resolution and a narrow spectral band width, with an effective area of 30 mm x 80 mm. The designed optical path of the X-ray spectrometer beam was 980 mm long from the source to the crystal and the detector. The first experiment was carried out at the 20 J energy laser facility of Research Center of Laser Fusion, China Academy of Engineering Physics. X-ray spectra in an ...

2008-02-01

456

Radiotherapy for ocular lesions by electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

Radiotherapy can be very significant as the treatment for ocular lesions, eyes need to be preserved as properly as possible on their functions and cosmetics. The application of conventional X ray therapy has been gradually abandoned as conventional X ray therapy ceased to be accepted as the general treatment for malignant tumors. Consequently the necessity of electron beam therapy has been rising even as the substituted method for conventional X ray therapy. The department of radiology of Gunma University was obliged to establish a new therapy for ocular lesions, and has been trying electron beam therapy since 1973. It is concluded that electron beam therapy is not at all inferior to conventional X ray therapy as reported above. Basic therapeutic methods for ocular lesions are the following: 1) For epidermoid carcinoma, ...

1981-11-01

457

Measurement of reactor tube cladding thickness by x-ray fluorescence spectrometry  

International Nuclear Information System (INIS)

An x-ray fluorescence spectrometer was designed and fabricated which nondestructively determines the thickness of aluminum cladding at small suspected thin spots in the inner or outer surface of actinide reactor tubes. The analysis method is based on the difference in absorption of actinide L/sub #alpha#/ and L/sub #beta#/ fluorescent x-rays in passing through the cladding. Calibration plots of the logarithm of the L/sub #beta#//L/sub #alpha#/ x-ray intensity ratio versus cladding thickness are linear to at least 40 mils for U-Al, U_3O_8-Al, and PuO_2-Al substrates. Accuracy and precision of the experimentally determined cladding thickness and evaluated for both uranium and plutonium substrates. Experimental thickness data are reported for 618 quality assurance analyses on six Mark 41 PuO_2-Al target tubes. An x-ray fluorescence cladding thickness monitor operated with a computer-controlled fluoroscope ...

1978-01-01

458

He-like ions as practical astrophysical plasma diagnostics: From stellar coronae to active galactic nuclei  

CERN Document Server

We review X-ray plasma diagnostics based on the line ratios of He-like ions. Triplet/singlet line intensities can be used to determine electronic temperature and density, and were first developed for the study of the solar corona. Since the launches of the X-ray satellites Chandra and XMM-Newton, these diagnostics have been extended and used (from CV to Si XIII) for a wide variety of astrophysical plasmas such as stellar coronae, supernova remnants, solar system objects, active galactic nuclei, and X-ray binaries. Moreover, the intensities of He-like ions can be used to determine the ionization process(es) at work, as well as the distance between the X-ray plasma and the UV emission source for example in hot stars. In the near future thanks to the next generation of X-ray satellites (e.g., Astro-H and IXO), higher-Z He-like lines (e.g., iron) will be resolved, allowing plasmas with ...

2011-01-01

459

Experimental Evaluation And Simulation Of Multi-pixel Cadmium-zinc-telluride Hard-x-ray Detectors  

CERN Document Server

This dissertation describes the evaluation of many-pixel Cadmium-Zinc-Telluride (CdZnTe) hard-X-ray detectors for future use with the High Energy Replicated Optics (HERO) telescope being developed at Marshall Space Flight Center. The detector requirements for the HERO application are good energy resolution (sufficient to resolve cyclotron features and nuclear lines), spatial resolution of ∼200 μm, minimal charge loss of absorbed X rays, and minimal sensitivity to the background environment. This research concentrates on assessing the suitability of these detectors for the focus of HERO, and includes the development of a simulation of the physics involved in an X-ray-detector interaction, a study of the intrinsic material properties, measurements with prototype detectors such as the energy and spatial resolution, charge loss, and X-ray background reduction through ...

2004-01-01

460

Dose, exposure time, and resolution in Serial X-ray Crystallography  

CERN Document Server

The resolution of X-ray diffraction microscopy is limited by the maximum dose that can be delivered prior to sample damage. In the proposed Serial Crystallography method, the damage problem is addressed by distributing the total dose over many identical hydrated macromolecules running continuously in a single-file train across a continuous X-ray beam, and resolution is then limited only by the available molecular and X-ray fluxes and molecular alignment. Orientation of the diffracting molecules is achieved by laser alignment. We evaluate the incident X-ray fluence (energy/area) required to obtain a given resolution from (1) an analytical model, giving the count rate at the maximum scattering angle for a model protein, (2) explicit simulation of diffraction patterns for a GroEL-GroES protein complex, and (3) the frequency cut off of the transfer function following iterative solution of the phase problem, ...

2007-01-01

461

Direct chemical information from special radiotracers as well as from outer X-ray excitation  

Energy Technology Data Exchange (ETDEWEB)

Radionuclides exhibiting in decaying a strong interaction between nucleus and electron shell (especially electron capture and internal conversion) are, in principle, sensitive to their chemical surroundings. Consequently, they can be used to yield chemical information after an appropriate labelling procedure. The information can be extracted from the decay rate variation as well as from their X-ray emission as a response to an inner-shell vacancy creation during nuclear deexcitation. As an example of the former method the relationship between the decay rate of /sup 99m/Tc and the chemical structures of pertechnetate and bis(meso-dimercapto-succinate)oxotechnetate(V) is considered. Lower expectations with respect to measuring techniques are associated with the observation of X-ray emission. For a number of elements (especially 3d transition elements) the K/sub ..cap alpha..//K/sub ..beta../ X-ray intensity ratio was found to ...

1983-09-01

462

Direct chemical information from special radiotracers as well as from outer X-ray excitation  

International Nuclear Information System (INIS)

Radionuclides exhibiting in decaying a strong interaction between nucleus and electron shell (especially electron capture and internal conversion) are, in principle, sensitive to their chemical surroundings. Consequently, they can be used to yield chemical information after an appropriate labelling procedure. The information can be extracted from the decay rate variation as well as from their X-ray emission as a response to an inner-shell vacancy creation during nuclear deexcitation. As an example of the former method the relationship between the decay rate of /sup 99m/Tc and the chemical structures of pertechnetate and bis(meso-dimercapto-succinate)oxotechnetate(V) is considered. Lower expectations with respect to measuring techniques are associated with the observation of X-ray emission. For a number of elements (especially 3d transition elements) the K/sub #alpha#//K/sub #betta#/ X-ray intensity ratio was found to be an ...

1982-10-01

463

Bendable Focusing X-Ray Optics for the ALS and the LCLS/FEL: Design, Metrology, and Performance  

Energy Technology Data Exchange (ETDEWEB)

We review the recent development of bendable x-ray optics used for focusing of beams of soft and hard x-rays at the Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory and at the Linac Coherent Light Source (LCLS) x-ray free electron laser (FEL) at the Stanford Linear Accelerator Center (SLAC) National Accelerator Laboratory. For simultaneous focusing in the tangential and sagittal directions, two elliptically cylindrical reflecting elements, a Kirkpatrick-Baez (KB) pair, are used. Because fabrication of elliptical surfaces is complicated, the cost of directly fabricated tangential elliptical cylinders is often prohibitive. Moreover, such optics cannot be easily readjusted for use in multiple, different experimental arrangements, e.g. at different focal distances. This is in contrast to flat optics that are simpler to manufacture and easier to measure by conventional interferometry. The tangential figure of ...

2010-06-02

464

A radionuclide analyzer of total sulfur in coal  

International Nuclear Information System (INIS)

The devised radionuclide analyzer for the determination of total sulfur in coal includes two radionuclide sources with different energies, which are accommodated in collimators fitted with adjustable diaphramgs. The sample compartment is located between the two sources. Moreover, an X-ray fluorescence standard can be slid into the sample compartment. A proportional detector for X-ray fluorescence and scattered gamma radiation is located off the sample compartment. The input of the proportional detector is interfaced to the output of a high-voltage supply, the output, to the information input of a control-and-evaluation unit. One of the control outputs of the control-and-evaluation unit is connected to the input of the sliding mechanism for the X-ray fluorescence standard. This arrangement enables automatic energy calibration of the analyzer. The analyzer can measure not only total sulfur in coal by radionuclide ...

1987-05-13

465

Heteroepitaxial growth of In-face InN on GaN (0001) by plasma-assisted molecular-beam epitaxy  

International Nuclear Information System (INIS)

The thermodynamic aspects of indium-face InN growth by radio frequency plasma-assisted molecular-beam epitaxy (rf-MBE) and the nucleation of InN on gallium-face GaN (0001) surface were investigated. The rates of InN decomposition and indium desorption from the surface were measured in situ using reflected high-energy electron diffraction and the rf-MBE 'growth window' of In-face InN (0001) was identified. It is shown that sustainable growth can be achieved only when the arrival rate of active nitrogen species on the surface is higher than the arrival rate of indium atoms. The maximum substrate temperature permitting InN growth as a function of the active nitrogen flux was determined. The growth mode of InN on Ga-face GaN (0001) surface was investigated by reflected high-energy electron diffraction and atomic force microscopy. It was found to be of the Volmer-Weber-type for substrate temperatures less than 350 deg. C and of the Stranski-Krastanov for substrate temperatures between 350 ...

2005-06-01

466

Stochastic risk estimation from medical x-ray diagnostic examinations, 2  

International Nuclear Information System (INIS)

The risks of genetic, leukemia and malignant diseases from medical X-ray diagnostic examinations were estimated using the frequency of radiographic and fluoroscopic exposures per diagnostic examination, child expectancy, leukemia and malignancy significant factors, and using a weighting factor determined on the basis of data concerning the cancer mortality among atomic bomb survivors in Nagasaki and of a recommendation of International Commission of Radiological Protection. The organ or tissue doses with respect to the stochastic risks were determined with ionization chambers and thermoluminescent dosimeters placed at the positions of the organs or tissues in a RANDO woman phantom which was exposed to diagnostic X-rays according to technical factors of typical radiographic and fluoroscopic examinations obtained from a nationwide survey. The resultant risks by age-group and type of radiographic and fluoroscopic examination are tabulated in terms ...

1981-01-01

467

Radiation exposure of children in pediatric radiology. Pt. 5. Organ doses in chest radiography; Zur Strahlenexposition von Kindern in der paediatrischen Radiologie. T. 5. Organdosen bei der Roentgenuntersuchung des Thorax  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Reconstruction of organ doses of selected organs and tissues from radiographic settings and exposure data collected during chest X-ray examinations of children of various age groups performed in Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007. Materials and Method: The dosimetric data of all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 119 150 chest radiographs of all age groups. Reconstruction of organ doses in 40 organs and tissues in X-ray examinations of the chest was performed based on the conversion factor concept. Results: The radiation exposure of organs in projection radiography is determined by the exact site of the organs relative to the edges of ...

2009-05-15

468

Nanofocusing refractive X-ray lenses  

Energy Technology Data Exchange (ETDEWEB)

This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is ...

2010-02-05

469

K/sub. beta. //K/sub. cap alpha. / transition probability ratios from the measurement of fluorescent X-ray intensities of some lanthanide compounds  

Energy Technology Data Exchange (ETDEWEB)

The effect that different chemical and physical atomic environments can have on the relative intensities of radiative electron transitions from the filling of K shell vacancies was investigated. The method used involved the detection of photoionization induced X-ray fluorescence. An experimental system based on a hyper pure germanium detector (HPGE) was used to measure the relative K-L and K-M X-ray yields from the photofluorescence of a series of lanthanide elements and compounds. A background subtraction and peak integration strategy was employed which accounted for scattering in the samples and scattering of the flux from the radioisotope photoionization sources. Analysis of the data resulted in a tabulation of relative K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ratios. The measured relative K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ratios were compared to the calculated values ...

1987-01-01

470

K/sub #beta#//K/sub #alpha#/ transition probability ratios from the measurement of fluorescent X-ray intensities of some lanthanide compounds  

International Nuclear Information System (INIS)

The effect that different chemical and physical atomic environments can have on the relative intensities of radiative electron transitions from the filling of K shell vacancies was investigated. The method used involved the detection of photoionization induced X-ray fluorescence. An experimental system based on a hyper pure germanium detector (HPGE) was used to measure the relative K-L and K-M X-ray yields from the photofluorescence of a series of lanthanide elements and compounds. A background subtraction and peak integration strategy was employed which accounted for scattering in the samples and scattering of the flux from the radioisotope photoionization sources. Analysis of the data resulted in a tabulation of relative K/sub #beta#//K/sub #alpha#/ X-ray intensity ratios. The measured relative K/sub #beta#//K/sub #alpha#/ X-ray intensity ratios were compared to the calculated values predicted by the ...

1987-01-01

471

A sample preparation for quantitative determination of magnesium in individual lymphocytes by electron probe X-ray microanalysis  

International Nuclear Information System (INIS)

We present a sample preparation method for measuring magnesium in individual whole lymphocytes by electron probe X-ray microanalysis. We use Burkitt's lymphoma cells in culture as the test sample and compare X-ray microanalysis of individual cells with atomic absorption analysis of pooled cell populations. We determine the magnesium peak-to-local continuum X-ray intensity ratio by electron probe X-ray microanalysis and calculate a mean cell magnesium concentration of 39 +- 19 mmol/kg dry weight from analysis of 100 cells. We determine a mean cell magnesium concentration of 34 +- 4 mmol/kg dry weight by atomic absorption analysis of pooled cells in three cell cultures. The mean cell magnesium concentrations determined by the two methods are not significantly different. We find a 10% coefficient of variation for both methods of analysis and a 30% coefficient of variation in magnesium concentration among ...

1986-01-01

472

X-ray magnetic form factor of UTe  

Energy Technology Data Exchange (ETDEWEB)

A measurement of the magnetic form factor of a ferromagnetic actinide compound of UTe with circularly polarized X-rays is reported. The present geometrical configuration of the measurement gives a form factor of L(k)+0.3S(k), where L(k) and S(k) are the form factors of the orbital and the spin magnetic moment, respectively. We have combined the X-ray magnetic form factor with the neutron one which gives L(k)+2S(k) (G. Busch et al.: J. Phys. C 12 (1979) 1391), and have deduced L(k) and S(k) separately. The obtained profiles of L(k) and S(k) show that the orbital and the spin magnetic moments are spatially spread out more than those calculated for a free uranium ion. (author).

1995-07-01

473

X-ray magnetic form factor of UTe  

International Nuclear Information System (INIS)

A measurement of the magnetic form factor of a ferromagnetic actinide compound of UTe with circularly polarized X-rays is reported. The present geometrical configuration of the measurement gives a form factor of L(k)+0.3S(k), where L(k) and S(k) are the form factors of the orbital and the spin magnetic moment, respectively. We have combined the X-ray magnetic form factor with the neutron one which gives L(k)+2S(k) (G. Busch et al.: J. Phys. C 12 (1979) 1391), and have deduced L(k) and S(k) separately. The obtained profiles of L(k) and S(k) show that the orbital and the spin magnetic moments are spatially spread out more than those calculated for a free uranium ion. (author).

474

X-ray imaging dose due to the digital imaging devices used in radiation therapy for patient positioning and repositioning: How to take it into account?; Les doses dues a l'imagerie numerique pour le controle de positionnement du patient en radiotherapie: comment les prendre en compte?  

Energy Technology Data Exchange (ETDEWEB)

The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)

2008-12-15

475

Theoretical considerations for X-ray phase contrast mammography by Thomson source  

Energy Technology Data Exchange (ETDEWEB)

The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase imaging with respect to standard absorption imaging, in the ...

2009-09-01

476

Studies of L x-rays from 64 MeV iodine projectiles in collision with gas targets  

International Nuclear Information System (INIS)

We have studied L x-rays from 64 MeV iodine projectile in collision with various gas targets, Z_2 #18, do not arise from selective M subshell vacancy population, has been conclusively established by the observations by Datz et al (1971) and by Saha et al (1996) that the measured intensity ratio of the Ll and L#alpha# lines, which arise because of transitions from different M subshells into the same L, subshell, does not show any periodic behaviour with Z, but stays rather constant. Differences in the measured L#beta#_1/L#alpha# intensity ratio of iodine with 7"+ and 24"+ charge states impinging on Kr target established the minor role of the electrons in the N shell of the projectile in the x-ray production mechanism. (author)

1997-11-17

477

Simulation Studies of the X-Ray Free-Electron Laser Oscillator  

Energy Technology Data Exchange (ETDEWEB)

Simulations of the x-ray free-electron laser (FEL) oscillator are presented that include transverse effects and realistic Bragg crystal properties with the two-dimensional code GINGER. In the present cases considered the radiation divergence is much narrower than the crystal acceptance, and the numerical algorithm can be simplified by ignoring the finite angular bandwidth of the crystal. In this regime GINGER shows that the saturated x-ray pulses have 109 photons and are nearly Fourier-limited with peak powers in excess of 1 MW. Wealso include preliminary results for a four-mirror cavity that can be tuned in wavelength over a few percent, with future plans to incorporate the full transverse response of the Bragg crystals into GINGER to more accurately model this tunable source.

2009-08-14

478

Sensitization and radiation hardening of the photostimulable X-ray storage phosphor CsBr:Eu2+  

British Library Electronic Table of Contents (United Kingdom)

The X-ray storage phosphor CsBr:Eu2+ in form of needle image plates is believed to be a promising alternative to the granular BaFBr:Eu2+ with regard to PSL yield and spatial resolution. Unfortunately, CsBr:Eu2+ exhibits poor radiation hardness, which is caused by a migration of europium ions initiated by naturally existing defect centers like (Eu2+-VCs)-centers and X-ray generated MEu-centers. It will be shown that the formation of (Eu2+-O2?)-dipoles at the expense of (Eu2+-VCs)-dipoles, incorporated by thermal annealing in O2-containing and humid atmosphere, does not improve the radiation stability. There is, however, a strong improvement in the radiation hardness by codoping of CsBr:Eu2+ with lithium ions, which is accompanied by a complete suppression of the previously observed MEu-cent...

2009-01-01

479

Radiation risk in computerized tomography (CT)  

Energy Technology Data Exchange (ETDEWEB)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on ...

1984-01-01

480

Radiation risk in computerized tomography (CT)  

International Nuclear Information System (INIS)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on ...

1984-01-01

481

Radiation risk in computerized tomography (CT)  

International Nuclear Information System (INIS)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on ...

482

Plasma Diagnostics in the Optical and X-ray regions on the Plasma Focus device PF-4 (Installation TYULPAN)  

International Nuclear Information System (INIS)

The results of experiments received on the plasma focus (PF) device with energy stored equal 4 kJ are represented. Photos of the current plasma sheath (CPS), pre-pinch, sphere-like plasma formations are produced with help of the electron-optical converter contained a gated micro-channel plate (MCP) and the CCD-camera imaging system in the visible region. The redial velocity of the CPS is about 107 cm/s. Neon plasma electron density measured with help of the interferograms in the visible region and the spectra in the soft X-ray region is equals to 3?1018 cm-3. Electron temperature is equal to about 200 eV. Discharge integral photos were obtained with help of the soft X-ray pinhole camera. Pictures with 2 ?s resolution of the plasma luminescence above PF anode region were made by CCD-camera.

2006-01-01

483

Operation of beam line facilities for real-time x-ray studies at Sector 7 of the advanced photon source. Final Report  

Energy Technology Data Exchange (ETDEWEB)

This Final Report documents the research accomplishments achieved in the first phase of operations of a new Advanced Photon Source beam line (7-ID MHATT-CAT) dedicated to real-time x-ray studies. The period covered by this report covers the establishment of a world-class facility for time-dependent x-ray studies of materials. During this period many new and innovative research programs were initiated at Sector 7 with support of this grant, most notably using a combination of ultrafast lasers and pulsed synchrotron radiation. This work initiated a new frontier of materials research: namely, the study of the dynamics of materials under extreme conditions of high intensity impulsive laser irradiation.

2003-09-10

484

Measurements of K-beta/K-alpha X-ray intensity ratios using VEC beams  

International Nuclear Information System (INIS)

An experiment on the K#beta#/K#alpha# characteristic X-ray intensity ratio in silver was performed at VEC Centre, Calcutta using the #alpha#-beams at energies 40 MeV and 50 MeV employing a Si(Li) detector system on-line. The results show that the K#beta#/K#alpha# X-ray intensity ratio at energies 40 and 50 MeV are 0.215 #+-# 0.006 and 0.216 #+-# 0.006, respectively, which indicates no change with beam energy and in accordance with the earlier reports. The present experiment shows the feasibility of studying the K#beta#/K#alpha# ratios as a function of beam energy in different regions of periodic table. Experiments in elements belonging to the 3d shell and their compounds are suggested to look for the chemical effects and their dependence on #alpha#-energy. (author). 7 refs.

1987-02-03

485

Laser Assisted Emittance Exchange: Downsizing the X-ray Free Electron Laser  

Energy Technology Data Exchange (ETDEWEB)

A technique is proposed to generate electron beam with ultralow transverse emittance through laser assisted transverse-to-longitudinal emittance exchange. In the scheme a laser operating in the TEM10 mode is used to interact with the electron beam in a dispersive region and to initiate the emittance exchange. It is shown that with the proposed technique one can significantly downsize an x-ray free electron laser (FEL), which may greatly extend the availability of these light sources. A hard x-ray FEL operating at 1.5 {angstrom} with a saturation length within 30 meters using a 3.8 GeV electron beam is shown to be practically feasible.

2009-12-11

486

K-edge X-ray absorption spectra of argon in sputtered aluminum films  

International Nuclear Information System (INIS)

We have measured K-edge X-ray absorption spectra of argon in sputtered aluminum films at a synchrotron radiation facility (the Photon Factory). We found that the energy and shape of white line change when the film is annealed at 500 C and the spectrum becomes resembling that of argon implanted in silicon. From the analyses of the X-ray absorption spectra and TEM observation we concluded that argon exists as very small atom clusters with a diameter less than 1 nm or exist as isolated atoms in the as-sputtered aluminum film, and that the size of the clusters become as big as 10 nm diameter when the film is heated. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

1999-01-04

487

Extraction methods of phase information for X-ray diffraction enhanced imaging  

Energy Technology Data Exchange (ETDEWEB)

X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more precision of refraction-angle values than existing methods.

2007-08-21

488

Extraction methods of phase information for X-ray diffraction enhanced imaging  

International Nuclear Information System (INIS)

X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more precision of refraction-angle values than existing methods.

2007-08-21

489

Exploring the Physics of Type Ia Supernovae Through the X-ray Spectra of their Remnants  

CERN Document Server

We present the results of an ongoing project to use the X-ray observations of Type Ia Supernova Remnants to constrain the physical processes involved in Type Ia Supernova explosions. We use the Tycho Supernova Remnant (SN 1572) as a benchmark case, comparing its observed spectrum with models for the X-ray emission from the shocked ejecta generated from different kinds of Type Ia explosions. Both the integrated spectrum of Tycho and the spatial distribution of the Fe and Si emission in the remnant are well reproduced by delayed detonation models with stratified ejecta. All the other Type Ia explosion models fail, including well-mixed deflagrations calculated in three dimensions.

2005-01-01

490

Electron beam, ion beam, X-ray optical techniques for fabricating surface-acoustic-wave and thin-film optical devices  

International Nuclear Information System (INIS)

Most surface-acoustic-wave and thin-film optical devices are made by the planar fabrication process. The exposure of the pattern in the polymer film is the first and most crucial step in ensuring desired device geometry, dimensional control, and freedom from pattern distortion. The methods of exposing the polymer film include: optical projection, conventional contact printing, conformable photomask contact printing, holographic recording, scanning electron beam lithography, projection electron lithography, and x-ray lithography. In this paper scanning electron beam lithography, conformable photomask contact printing, holographic recording, and x-ray lithography are discussed. In the last section, ion beam etching of relief structures is discussed.

491

Design considerations for the magnetic system of a prototype x-ray free electron laser  

Energy Technology Data Exchange (ETDEWEB)

A number of difficult technical challenges need to be solved in the fields of accelerator and free-electron laser (FEL) technologies in order to build an X-ray FEL. One of the tasks well suited to the Advanced Photon Source Low Energy Undulator Test Line (LEUTL) is to take the intermediate step of solving some of the problems of single-pass FEL operation in the ultraviolet range. The existing Advanced Photon Source (APS) linac, in addition to its role of supply positrons for the APS storage ring, will also be used to generate the particle beam for the LEUTL. Here, the design of the magnetic system for the high gain soft x-ray free electron laser is described.

1997-04-01

492

Crystallization and preliminary X-ray studies of a galactose-specific lectin from the seeds of Spatholobus parviflorus  

British Library Electronic Table of Contents (United Kingdom)

A galactose-specific seed lectin was purified from the legume Spatholobus parviflorus and crystallized using the hanging-drop vapour-diffusion technique. Thecrystals belonged to space group P1, with unit-cell parameters a = 60.998, b=60.792, c = 78.179-, = 101.32, = 91.38, = 104.32. X-ray diffraction data were collected under cryoconditions (100-K) to a resolution of 2.04- using a MAR image-plate detector system mounted on a rotating-anode X-ray (Cu-K) generator. Molecular replacement using legume-lectin coordinates as a search model gave a tetrameric structure.

2011-01-01

493

Cluster Geometry & Inclinations from Deprojection Uncertainties  

CERN Document Server

{The determination of cluster masses is a complex problem that would be aided by information about the cluster shape and orientation (along the line-of-sight).} {It is in this context, that we have developed a scheme for identifying the intrinsic morphology and inclination of a cluster, by looking for the signature of the true cluster characteristics in the inter-comparison of the different deprojected emissivity profiles (that all project to the same X-ray brightness distribution) and by using SZe data when available.} {We deproject the cluster X-ray surface brightness profile under the assumptions of four different geometry and inclination configurations for the observed system; these 4 configurations correspond to four extreme geometry+inclination scenarios. The deprojection in question is performed by the non-parametric algorithm DOPING. The formalism is tested with model systems and then is applied to a sample of 24 clusters. While the ...

2008-01-01

494

Characterisation and use of biomass fly ash in cement-based materials  

British Library Electronic Table of Contents (United Kingdom)

This paper presents results about the characterisation of the biomass fly ashes sourced from a thermal power plant and from a co-generation power plant located in Portugal, and the study of new cement formulations incorporated with the biomass fly ashes. The study includes a comparative analysis of the phase formation, setting and mechanical behaviour of the new cement-fly ash formulations based on these biomass fly ashes. Techniques such as X-ray diffraction (XRD), X-ray fluorescence spectroscopy (XRF), thermal gravimetric and differential thermal analysis (TG/DTA), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and environmental scanning electron spectroscopy (ESEM) were used to determine the structure and composition of the formulations. Fly ash F1 from the t...

2009-01-01

495

Association of brain cancer with dental x-rays and occupation in Missouri  

International Nuclear Information System (INIS)

This investigation of a brain cancer cluster in Missouri used two approaches to investigate associations with potential risk factors. In a case-control study in a rural town, we interviewed surrogates of cases and controls about potential risk factors. We found a statistically significant positive association of brain cancer with reported exposure to dental x-rays. Occupation was not associated with the cluster in the rural town. In a standardized proportional mortality study for the state of Missouri, we calculated the observed and expected proportion of brain cancers by occupation and industry in Missouri decedents. We found that motor vehicle manufacturers, beauty shop workers, managers and administrators, elementary school teachers, and hairdressers and cosmetologists had significantly elevated proportions of brain cancer. Brain tumors are inconsistently associated with occupation in the literature. Further study of brain cancer etiology with respect to dental ...

1991-01-01

496

A soft x-ray free electron laser (FEL) using a two-beam elliptical pill-box wake-field cavity  

International Nuclear Information System (INIS)

Stimulated bremsstrahlung in an undulating electric field in the lasing beam direction (electric wiggler) was shown to be possible from the quantum- mechanical viewpoint. Herein, this possibility is scrutinized from the viewpoint of classical electrodynamics. It is found that if stimulated bremsstrahlung in a transverse undulating magnetic field (magnetic wiggler) occurs, stimulated bremsstrahlung in the electric wiggler must also occur. We further show that a free electron laser (FEL) using a magnetic wiggler to provide a catalyzer field for stimulated bremsstrahlung cannot serve as a practical FEL operating in the soft x-ray region from both theoretical and experimental viewpoints. On the other hand, the authors demonstrate that the FEL using a traveling wake field in a two-beam elliptical pill-box cavity is well suited as a source of coherent radiation in the soft x-ray region.

1988-01-14