WorldWideScience
1

Study of iodine migration in zirconia using stable and radioactive ion implantation  

Energy Technology Data Exchange (ETDEWEB)

The large uranium fission cross section leading to iodine and the behaviour of this element in the cladding tube during energy production and afterwards during waste storage is a crucial problem, especially for {sup 129}I which is a very long half-life isotope (T=1.59 x 10{sup 7} yr). Since a combined external and internal oxidation of the zircaloy cladding tube occurs during the reactor processing, iodine diffusion parameters in zirconia are needed. In order to obtain these data, stable iodine atoms were first introduced by ion implantation into zirconia with an energy of 200 keV and a dose equal to 8 x 10{sup 15} at cm{sup -2}. Diffusion profiles were measured using 3 MeV alpha-particle Rutherford backscattering spectrometry at each step of the annealing procedure between 700 C and 900 C. In such experiments a reduced iodine concentration was observed, which correlated to a diffusion-like process. Similar analysis has been performed using ...

1998-03-01

2

The investigations on K and L X-ray fluorescence parameters of gold compounds  

British Library Electronic Table of Contents (United Kingdom)

The study aimed to determine the chemical effects on the K and L X-ray intensity ratios and the K and L X-ray production cross sections for gold compounds. The K shell fluorescence yields and L shell average yields were also investigated. The samples were excited by 59.5keV ?-rays from an 241Am annular radioactive source and 123.6keV ?-rays from a 57Co annular radioactive source. K and L X-rays emitted from samples were counted by an Ultra-LEGe detector with a resolution of 0.150keV at 5.9keV. The experimental values were compared with theoretical, the semi-empirical and other experimental values.

2010-01-01

3

Negative-ion based NBI system for JT-60U  

Energy Technology Data Exchange (ETDEWEB)

A 500 keV negative-ion based NBI system is under construction for NB current drive and plasma core heating in high density plasma in JT-60U. Part of the beamline and the high voltage power supply required for a verification test of an ion source was completed in March 1995. After having done a high potential test of the power supply, the negative-ion generation and acceleration tests started in June 1995 aiming at deuterium beams of 500 keV, 22A. In initial experiment, deuterium negative-ion beams of 410 keV, 6.1A (2.5 MW) for 0.2 sec, so far, have been achieved. This is the world highest D{sup {minus}} current and negative ion beam power. The construction of the total system will be completed by the beginning of 1996, and the beam injection will start in March 1996.

1995-12-31

4

Progress of negative-ion based NBI system for JT-60U  

Energy Technology Data Exchange (ETDEWEB)

The operation of the negative ion based NBI system for JT-60U has been progressed since 1996. Most of the efforts in the operation for increasing beam power and energy have been concentrated to get over the troubles, caused by surge energy at the moment of the accelerator break-down, in the ion sources and high voltage power supplies. The ion source for the N-NBI, so far, has accelerated negative ion beams of 14.3 A at 380 keV with deuterium and 18.5 A at 360 keV with hydrogen against the target of 22 A. The neutral beam power injected into JT-60U has already reached 5.2 MW at 350 keV for 0.7 sec with deuterium. (author)

1998-07-01

5

Annealing behavior of radiation damages in metal-silicides  

International Nuclear Information System (INIS)

The annealing behavior of the radiation damage in epitaxial Pd_2Si and NiSi_2 films on Si, due to the implantation of 100 keV Ar ions, is investigated by using the channeling technique with "4He ions. (U.K.).

6

Ion sources for initial use at the Holifield radioactive ion beam facility  

Energy Technology Data Exchange (ETDEWEB)

The Holifield Radioactive Ion Beam Facility (HRIBF) now under construction at the Oak Ridge National Laboratory will use the 25-MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility; the choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. A high-temperature version of the CERN-ISOLDE positive ion source has been selected and a modified version ...

1994-12-31

7

Ion sources for initial use at the Holifield Radioactive Ion Beam Facility  

Energy Technology Data Exchange (ETDEWEB)

The Holifield Radioactive Ion Beam Facility (HRIBF) now under construction at the Oak Ridge National Laboratory will use the 25-MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility; the choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. A high-temperature version of the CERN-ISOLDE positive ion source has been selected and a modified version ...

1994-05-01

8

Electron collisional detachment processes for a 250 keV D/sup -/ ion beam in a partially ionized hydrogen target  

Energy Technology Data Exchange (ETDEWEB)

Neutral atom beams with energies above 200 keV may be required for various purposes in magnetic fusion devices following TFTR, JET and MFTF-B. These beams can be produced much more efficiently by electron detachment from negative ion beams than by electron capture by positive ions. We have investigated the efficiency with which such neutral atoms can be produced by electron detachment in partially ionized hydrogen plasma neutralizers.

1980-09-01

9

Electron detachment cross-sections and secondary-electron emission factors for heavy-negative-ion beams  

Energy Technology Data Exchange (ETDEWEB)

The properties of negative-ion beams are very important for designing negative-ion apparatus and applications of negative-ion beams, especially, electron detachment cross-sections at the interaction between negative-ion beams and gas particles in the transport system, and secondary-electron emission factors when negative ions are incident on solid surfaces. These properties of negative-ion beams were investigated experimentally as a function of the ion energy under 50 keV. The single electron detachment cross-sections are almost constant in the other of 10[sup -15] cm[sup 2] in this energy range, but double electron detachment cross-sections increase in proportion to the ion velocity and much smaller than the single one. As for the secondary-electron emission factor, the emission factors for ...

1994-01-01

10

Electron detachment cross-sections and secondary-electron emission factors for heavy-negative-ion beams  

International Nuclear Information System (INIS)

The properties of negative-ion beams are very important for designing negative-ion apparatus and applications of negative-ion beams, especially, electron detachment cross-sections at the interaction between negative-ion beams and gas particles in the transport system, and secondary-electron emission factors when negative ions are incident on solid surfaces. These properties of negative-ion beams were investigated experimentally as a function of the ion energy under 50 keV. The single electron detachment cross-sections are almost constant in the other of 10"-"1"5 cm"2 in this energy range, but double electron detachment cross-sections increase in proportion to the ion velocity and much smaller than the single one. As for the secondary-electron emission factor, the emission factors for ...

1994-01-01

11

The characteristics of ion-beam-induced spontaneous etching of GaAs by low-energy focused ion beam irradiation  

International Nuclear Information System (INIS)

We have investigated the characteristics of ion-beam-induced spontaneous etching (IBISE) of GaAs in Cl_2 ambient by using a Ga-focused ion beam (FIB) with an energy ranging from 3 to 15 keV. The etched depth of the irradiated region was more than 20 times greater than that of unirradiated region. When the sputtered depth by FIB irradiation amounted to around 8 A at each ion energy, the etched depth in Cl_2 ambient for 1 hour became saturated. The saturated etched depths were 450, 550, 750 and 800 A at the ion energy of 3, 5, 10 and 15 keV, respectively. The residual damage of the etched surface was also investigated by photoluminescence (PL) measurement. The maximal PL intensity was obtained at around the threshold dose of IBISE and increased with decreasing ion energy. The full recovery of PL intensity was observed at the ...

12

Nanoporous structure formations on germanium surfaces by focused ion beam irradiations  

International Nuclear Information System (INIS)

The formation of porous structures of nanometre size (nanoporous structures) on germanium (Ge) surfaces by focused ion beam (FIB) irradiations was investigated using various FIB conditions such as ion species, irradiation energies, total fluences, fluence rates, and incident angles. FIB-irradiated regions were observed using a scanning electron microscope and an atomic force microscope. It is found that, using a focused Ga ion beam (Ga FIB) at an energy of 100 keV, the irradiated Ge surface swelled up to ion fluence of 2 x 10"1"7 cm"-"2 with nanoporous structures and then was etched for larger fluences. The shape of swollen nanoporous structures depended on the fluence rate and the incident angle of the Ga FIB. However, such porous structures were observed neither for low-energy (15-30 keV) FIB irradiations using Si and Au ions nor for ...

2007-11-07

13

Focused ion beam processes for high-T/sub c/ superconductors  

International Nuclear Information System (INIS)

Focused ion beam (FIB) processes have been developed for Y--Ba--Cu--O superconductor films. A Y--Cu liquid metal ion source has been fabricated, using a Y_6_7 --Cu_3_3 eutectic alloy as the ion source. As-sputtered Y--Ba--Cu--O film etch rate ratios to GaAs(100) and Si(100) substrates are 0.28 and 1.4 for 130-keV Au"+ FIB ion etching, respectively. Y--Ba--Cu--O submicron patterns have been demonstrated by using FIB lithography and Cl_2 reactive ion beam etching. Moreover, a Y--Ba--Cu--O superconducting line with 4-#mu#m linewidth has been fabricated by annealing an as-sputtered Y--Ba--Cu--O line pattern. T/sub c/ control of Y--Ba--Cu--O film has been achieved by 200-keV Ne"+, using conventional ion implantation and 300 keV Si"+"+ FIB ion implantation.

14

0--30 keV low-energy focused ion beam system  

Energy Technology Data Exchange (ETDEWEB)

Low-energy focused ion beam (FIB) is a useful tool for shallow doping, gas-assisted etching, and other uses to minimize substrate damage in semiconductor device fabrication. The possibility to form a finely FIB of low energy under 1 keV was suggested in the investigations on the retarding mode in electron optical systems. The abilities of the simplest type of retarding mode FIB column are examined here. The optical properties are calculated for the corresponding model and some images are observed with Ga/sup +/ ion beams <0.3 ..mu..m in diameter for beam energies, 10, 5, and 1 keV, using a retarding mode one-lens FIB system. 1-keV and 100-eV Ga/sup +/ FIB was implanted to Ga/As substrate, and the defects are analyzed by deep-level transient spectroscopy. The defect concentration for 100 eV was < (1)/(5) that for 1000 keV.

1988-05-01

15

0--30 keV low-energy focused ion beam system  

International Nuclear Information System (INIS)

Low-energy focused ion beam (FIB) is a useful tool for shallow doping, gas-assisted etching, and other uses to minimize substrate damage in semiconductor device fabrication. The possibility to form a finely FIB of low energy under 1 keV was suggested in the investigations on the retarding mode in electron optical systems. The abilities of the simplest type of retarding mode FIB column are examined here. The optical properties are calculated for the corresponding model and some images are observed with Ga"+ ion beams <0.3 #mu#m in diameter for beam energies, 10, 5, and 1 keV, using a retarding mode one-lens FIB system. 1-keV and 100-eV Ga"+ FIB was implanted to Ga/As substrate, and the defects are analyzed by deep-level transient spectroscopy. The defect concentration for 100 eV was < (1)/(5) that for 1000 keV.

16

Protons, heavy ions, radioactive beams: new ways for radiotherapy. Protons, ions lourds, faisceaux radioactifs: de nouvelles voies pour la radiotherapie  

Energy Technology Data Exchange (ETDEWEB)

In this article, the author presents the principles, applications and advantages of proton and heavy ion beams used for radiotherapy.

1993-07-01

17

Improved FNAL linac beam choppers  

Energy Technology Data Exchange (ETDEWEB)

A discussion is presented of the 750-KeV chopper experience with both proton and negative ion beams and the ability of these systems to tailor the Linac beam to the diverse requirements of its users; normal accelerator injection, neutron therapy beam, and electron cooling experiments. This flexibility plus a cleaner beam pulse, improved thyratron operation, and mechanical modularity are the results of recent improvements. Additional benefits have been increased reliability and ease of service to the 750-KeV chopper. 3 refs.

1981-06-01

18

Improvement on Liquid Radioactive Waste Treatment System of Nuclear Power Plant By Applying Ion Exchange Method  

International Nuclear Information System (INIS)

Liquid radioactive waste treatment method of using evaporator was widely used from Kori 1 to Uljin 3 and 4, but a liquid radioactive waste treatment equipment that uses an ion exchange method instead of an evaporator was adopted aiming to minimize amount of radioactive waste and radiation exposure. However, the same equipment was introduced and applied for the first time in Korea and had experienced difficulties in securing credibility for the equipment and handling of liquid radioactive waste with inadequate data about performance and experience in operation and maintenance. In this study, examination, application and effect analysis was performed on the optimization measure for handling liquid radioactive waste of Yonggwang Nuclear Power Unit 5 and 6(YGN 5 and 6) that applies an ion exchange method

2010-10-01

19

The study of the ion beam induced swelling in crystalline germanium irradiated by a 30 keV Ga"+ focused ion beam  

International Nuclear Information System (INIS)

The effect of swelling of crystalline Ge irradiated at room temperature with 30 keV Ga"+ focused ion beam (FIB) was studied by means of in situ FIB imaging, atomic force microscopy (AFM) and transmission electron microscopy (TEM). The swelling occurred in the surface region of amorphous damage layer which was formed during ion irradiation. The degree of swelling reaches values up to 10 times for an implantation dose of #approx#10"1"7 ions/cm"2. Cross-secitonal TEM examination showed that the swelling is due to formation of a porous layer with a honeycomb structure. (author). 8 refs., 4 figs.

2005-11-20

20

Ion beam pulsing for time of flight (TOF) experiments  

Energy Technology Data Exchange (ETDEWEB)

The essential mechanical and electronic parts of a beam pulsing system are described, which reaches an energy resolution of ..delta..E/E=0.1%-0.4% in the energy range from 100 eV and 10 keV.

1985-01-01

21

Photodetachment of negative ion beams in the presence of a background gas  

Energy Technology Data Exchange (ETDEWEB)

To suppress space charge blowup in an ion beam passing through a photoneutralizer, it is necessary to introduce some background gas. An analysis is presented of the neutralization of a high-energy, >200-keV negative deuterium ion beam, exposed to photodetachment while in the presence of deuterium. With a gas thickness of <0.01 Torr.cm, the neutral fraction in the output beam is found to be about the same as that gotten from the photoneutralizer operating in vacuum. Neutral atom beam injection for plasma heating is discussed.

1987-03-01

22

Double-electron-capture cross section for I/sup +/ in a magnesium-vapor target  

Energy Technology Data Exchange (ETDEWEB)

Measurements of the double-electron-capture process in which a positive ion of iodine becomes a negative ion in a single collision with a magnesium atom are reported between 20 and 90 keV. The cross section is comparable to that for the rare gases and not as large as might be expected from a two-valence-electron atom. This process is probably insignificant in the production of negative ion beams using a magnesium-vapor target.

1987-06-15

23

Focused Ion Beam Induced Effects on MOS Transistor Parameters  

Energy Technology Data Exchange (ETDEWEB)

We report on recent studies of the effects of 50 keV focused ion beam (FIB) exposure on MOS transistors. We demonstrate that the changes in value of transistor parameters (such as threshold voltage, V{sub t}) are essentially the same for exposure to a Ga+ ion beam at 30 and 50 keV under the same exposure conditions. We characterize the effects of FIB exposure on test transistors fabricated in both 0.5 {micro}m and 0.225 {micro}m technologies from two different vendors. We report on the effectiveness of overlying metal layers in screening MOS transistors from FIB-induced damage and examine the importance of ion dose rate and the physical dimensions of the exposed area.

1999-07-28

24

5.6-nm p"+/n junction formation for sub-0.05-#mu#m PMOSFETs by using low-energy B_1_0H_1_4 ion implantation  

International Nuclear Information System (INIS)

Decaborane (B_1_0H_1_4) cluster ions were implanted into n-Si(100) substrates to fabricate shallow p"+/n junctions. Implant energies of 2 keV, 5 keV, and 20 keV, equivalent to implant energies of the monomer boron ion of 174 eV, 435 eV, and 1.74 keV, respectively, were used at dosages of 1 X 10"1"2 /cm"2 and 1 X 10"1"3 /cm"2. The implanted samples were then subjected to activation annealing at 800 .deg. C, 900 .deg. C, and 1000 .deg. C for 10 s. By using secondary ion mass spectrometry (SIMS) depth profiles, we determined that the depth of the shallow junction (D_s) at a dosage of 1 X 10"1"3 /cm"2 was in the range 12 nm - 45 nm after annealing at 1000 .deg. C. D_s and transient enhanced diffusion (TED) were greatly reduced at implant energies lower than 5 keV, but thermal diffusion (TD) smoothly decreased. In particular, ...

2004-06-01

25

Selection and design of ion sources for use at the Holifield radioactive ion beam facility  

Energy Technology Data Exchange (ETDEWEB)

The Holifield Radioactive Ion Beam Facility now under construction at the Oak Ridge National Laboratory will use the 25 MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility. The choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. Although direct-extraction negative ion sources are clearly desirable, the ion formation ...

1994-06-01

26

The effects of energy non-monochromaticity of "1"1B ion beams on "1"1B diffusion  

International Nuclear Information System (INIS)

We have shown that energy contamination introduced by ion beam deceleration technology that is used to increase the beam currents available for low energy boron implants, can affect fabricated junctions adversely. A 4 keV "1"1B beam is extracted and retarded by a potential of -3.5 keV for 0.5 keV "1"1B implantation, or by a potential of -3.8 keV for 0.2 keV "1"1B implantation. Intentional beam contamination was introduced by turning off the retarding potential to allow the 4 keV "1"1B ions to irradiate Si wafers directly. The percentage of contamination, at levels of 0.1%, 0.2% and 0.3% was introduced. Rapid thermal annealing of all the implanted samples was performed under N_2 ambient at 1050 deg. C for 1 s. The dopant tail profiles themselves are not significant if the contamination levels are low. However, the much ...

2005-08-01

27

High current implantation of negative copper ions into silica glasses  

Energy Technology Data Exchange (ETDEWEB)

High-current implantation of Cu{sup {minus}} ions into silica glasses has been demonstrated using mA-class negative ion beams at 60 keV. Negative ion implantation has an advantage to alleviate specimen charging for insulating substrates and has attained high dose rates, up to 260 {micro}A/cm{sup 2}. Spherical Cu colloids form in the silica glasses without additional thermal annealing. Optical absorption and reflection of the implanted specimens vary with the current density, even at a fixed dose level. A beam-induced surface plasma may affect the high current implantation.

1997-12-01

28

Long pulse production of high current D"- ion beams in the JT-60 negative ion source  

International Nuclear Information System (INIS)

The first long pulse production of high power D"- ion beams has been demonstrated in the JT-60 U negative ion sources, each of which was designed to produce 22 A, 500 keV D"- ion beams. Voltage holding capability and the grid power loading were examined for long pulse production of high power D"- ion beams. From the correlation between voltage holding and the light intensity of cathodoluminescence from the Fiber Reinforced Plastic insulators, the acceleration voltage for stable voltage holding capability was found to be less than 320-340 kV where the light was sufficiently suppressed. By tuning the extraction voltage, the grid power loadings in the ion sources were decreased to the allowable levels for long pulse injection without a significant reduction of the beam power. After tuning the acceleration and extraction voltages, D"- ion beams ...

2008-02-01

29

MODELING AN ION EXCHANGE PROCESS FOR CESIUM REMOVAL FROM ALKALINE RADIOACTIVE WASTE SOLUTIONS  

Energy Technology Data Exchange (ETDEWEB)

The performance of spherical Resorcinol-Formaldehyde ion-exchange resin for the removal of cesium from alkaline radioactive waste solutions has been investigated through computer modeling. Cesium adsorption isotherms were obtained by fitting experimental data using a thermodynamic framework. Results show that ion-exchange is an efficient method for cesium removal from highly alkaline radioactive waste solutions. On average, two 1300 liter columns operating in series are able to treat 690,000 liters of waste with an initial cesium concentration of 0.09 mM in 11 days achieving a decontamination factor of over 50,000. The study also tested the sensitivity of ion-exchange column performance to variations in flow rate, temperature and column dimensions. Modeling results can be used to optimize design of the ion exchange system.

2008-08-26

30

Comparison of beam-induced deposition using ion microprobe  

International Nuclear Information System (INIS)

The localized Pt deposition on Si by 30 keV Ga"+ focused ion beam (FIB), 10 keV electron beam (EB) or dual beams (FIB and EB) using precursor gas has been compared by analysis using a 300 keV Be"2"+ microprobe with a beam spot size of 80 nm. The distribution of deposited Pt, Ga from the ion beam itself, and C from the precursor gas was obtained at and nearby the deposited areas by micro-RBS spectra and RBS mapping. All of the beam processed areas showed a uniform Pt distribution at the deposited areas. The amount of Pt atoms increased with the increase in ion or electron dose due to the decomposition of precursor gas. The thickness of Pt layer by EB is considerably less than that by FIB due to the reduced deposition rate. Ga atoms from the center of processed areas partly redeposited at and nearby the FIB processed areas within #approx#3 #mu#m. The Ga ...

1999-01-02

31

Microfabrication processes for high-T_c superconducting films  

International Nuclear Information System (INIS)

Microfabrication processes for Y-Ba-Cu-O films have been investigated, using ion-beam techniques. High-T_c superconducting lines as narrow as 0.8 #mu#m have been fabricated from epitaxial YBa_2Cu_3O_7 _- _y films by Ar ion-beam etching (IBE), combined with focused ion-beam (FIB) lithography. The resulting lines, 1.3 #mu#m wide and 2 mm long, showed a zero resistance temperature of 81 K and a critical current density of 1.9 x 10"4 A/cm"2 at 77.3 K. Maskless etching was carried out using 130-keV au"+ focused ion-beam (FIB) with a 0.1-#mu#m-diameter beam. A 50-nm-thick film was patterned into 0.3-#mu#m-wide lines at a dose of 5 x "1"6 ions/cm"2. In comparison with Ar IBE, Cl_2 reactive ion-beam etching (RIBE) exhibited an enhancement effect in sputtering yield. Ion implantation with 300-keV Si"+ "+ FIB ...

32

Comparison of methods to measure the rate of neutral free radical production by photo-deionization of negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

Two measurement methods to determine the rate of neutral free radical production by the photo-deionization of negative ion beams (PDINIB) are introduced. These methods, namely, photoelectron-current measurement by low-frequency electro-modulation probe (PMMP) and measurement of decrease in the negative-ion beam current (DNIC) were employed to evaluate the production rate in a trial surface-processing apparatus developed in the author's laboratory utilizing a steady-flux refined beam of neutral free radicals (RBNR) produced by the PDINIB procedure. A {sup 63}Cu{sup -} negative ion beam of kinetic energy E{sub i} varied up to 15 keV was irradiated with a 514.5 nm visible light beam from a 25 W CW Ar{sup +} ion laser. The detection limit of the production rate by the PMMP setup was as high as 6 x 10{sup 9} s{sup -1} under the condition that E{sub i}=15 ...

2003-05-01

33

Intensity of auger-emission of silicon from binary compounds in the ion auger spectroscopy  

International Nuclear Information System (INIS)

Auger-electron emission from different silicides has been studied for 4 and 10 keV Ar ion excitation. The intensity of the SiLMM Auger line changes significantly with channing concentration and atomic number of the metal-parthner. The experimental results can be explained in terms of a simple model based on the probability of Si-Si collision symmetric cascade in these binary compounds.

34

Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization  

Energy Technology Data Exchange (ETDEWEB)

The measurements of the K X-ray intensity ratio I(K{alpha} {sub 2}/K{alpha} {sub 1}), I(K{beta} {sub 1}/K{alpha} {sub 1}) and I(K{beta}/K{alpha}) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a {sup 241}Am and 123.6 keV {gamma}-rays from a {sup 60}Co were used, and following the radioactive decay of {sup 51}Cr, {sup 55}Fe, {sup 67}Ga, {sup 99}Tc, {sup 111}In, {sup 131}I, {sup 133}Ba, {sup 133}Xe, {sup 137}Cs, {sup 201}Tl and {sup 226}Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.

2007-01-15

35

Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization  

International Nuclear Information System (INIS)

The measurements of the K X-ray intensity ratio I(K#alpha# _2/K#alpha# _1), I(K#beta# _1/K#alpha# _1) and I(K#beta#/K#alpha#) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV #gamma#-rays from a "2"4"1Am and 123.6 keV #gamma#-rays from a "6"0Co were used, and following the radioactive decay of "5"1Cr, "5"5Fe, "6"7Ga, "9"9Tc, "1"1"1In, "1"3"1I, "1"3"3Ba, "1"3"3Xe, "1"3"7Cs, "2"0"1Tl and "2"2"6Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.

2007-01-01

36

Measurement of the 183 keV Resonance in 17O(p,alpha)14N using a Novel Technique  

Energy Technology Data Exchange (ETDEWEB)

We have developed a novel technique for measurements of low energy (p,alpha) reactions using heavy ion beams and a differentially-pumped windowless gas target. We applied this new approach to study the 183 keV resonance in the 17O(p,alpha)14}N reaction. We report a resonance energy (center-of-mass) of 183.5{+0.1}{-0.4} keV, a resonance strength of 1.70 +/- 0.15 meV, and set an upper limit (95\\% confidence) on the total width of the state of < 0.1 keV. This resonance is important for the 17O(p,alpha)14}N reaction rate, and we find that 18F production is significantly decreased in low mass ONeMg novae but less affected in more energetic novae. We also report the first determination of the stopping power for oxygen ions in hydrogen gas near the peak of the Bragg curve (E=193 keV/u) to be (63+/-1)e-15 eV-cm2.

2007-06-01

37

Analysis of the chemical transformations induced at the surface of polyacrylonitrile and polymethacrylonitrile films by 5 keV proton beams  

Energy Technology Data Exchange (ETDEWEB)

In this work, the chemical transformations induced by 5 keV protons (10{sup 6} ion cm{sup -2}) at the surface of 0.4 {mu}m polyacrylonitrile and polymethacrylonitrile films are analysed by XPS and IRRAS. Spectroscopic changes in both the polymers are globally similar, the most significant feature being a lower relative concentration of nitrogen with respect to carbon closer to the surface. Quantitatively, this change is more marked in the case of polyacrylonitrile which suggests a direct relation with the hydrogen in {alpha} to the nitrile function.

1999-05-02

38

Radioactive liquid effluent processing with borohydride ions. Procede de traitement d'effluents liquides radioactifs au moyen d'ions borohydrure  

Energy Technology Data Exchange (ETDEWEB)

A borohydride, for instance sodium borohydride, is added to the radioactive effluent, with eventually a carrier such as Cu{sup +}, to give a precipitate containing ruthenium. The processing can be combined to Sr and Cs precipitation be know processes giving barium sulfate and nickel ferrocyamide precipitates. Influence of borohydride concentration on decontamination factor is given.

1989-08-25

39

Treatment of radioactive liquid waste by reverse osmosis; Influence of co-existing ions on the change of decontamination factor  

Energy Technology Data Exchange (ETDEWEB)

The report addresses the application of reverse osmosis to the treatment of radioactive liquid waste, focusing on the effects of non-radioactive cations and anions, existing in radioactive waste, on the removal of radioactive nuclides. The bivalent cations are generally about ten times as high in decontamination factor as monovalent ones. In the case of anions, the factor of SO{sub 4}{sup 2-} is about ten times that of Cl{sup -} while that of NO{sub 3}{sup -} is somewhat smaller than that of Cl{sup -}. During permeation through membrane, anions tend to accompany cations, and the decontamination factor of accompanying ions is found to increase with that of the paring ions. These results indicate that if one can select components that will remain in the liquid waste, one should consider their effects on the efficiency of its treatment. Furthermore, the interaction ...

1991-01-01

40

Improving the mechanical properties of steels using low energy, high temperature nitrogen ion implantation  

Energy Technology Data Exchange (ETDEWEB)

The use of nitrogen ion implantation to increase the surface hardness of structural steels is well documented. Traditionally this involves the use of high energy nitrogen ion beams (approximately 100 keV), with a relatively low beam current density because high energy beams are necessary to produce the required penetration into the material to achieve a significant depth of hardened material. Hardening needs to occur in a region whose size is comparable with the scale of the deformation associated with the tribocontact. 100 keV nitrogen ions typically penetrate into steels only about 0.1 {mu}m and the range of possible tribological applications is thus restricted by this shallow treatment depth. In plasma nitriding processes the nitrogen ions approach the substrate with much lower energies but the ion currents are sufficiently high to cause ...

1996-09-01

41

Development of high power negative ion sources for fusion at JAERI  

Energy Technology Data Exchange (ETDEWEB)

Technologies producing high power negative ion beams have been highly developed in these years at JAERI for use in neutral beam injectors for heating the thermonuclear fusion plasmas. At present, it is possible to produce multi-ampere H-/D- ion beams quasi-continuously at energies more than a few hundred keV with a good beam optics of beamlet divergence of a few milli-radian. Based on these technologies, two R and D projects have been initiated; one is to develop a 22A/500keV/10s D- ion source for the neutral beam injector for JT-60U, and the other is to develop a 1A/1MeV/60s H- ion source to demonstrate high current negative ion acceleration up to the energy of 1MeV, the energy required for the neutral beam injector for International Thermonuclear Experimental Reactor (ITER). (author).

1995-10-01

42

Deposition of Cu film on SiO_2 using a partially ionized beam  

International Nuclear Information System (INIS)

Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO_2 substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio I(111)/I(200) reaches its maximum value indicating a strong left-angle 111 right-angle texture, while the ...

1990-01-01

43

Deposition of Cu film on SiO sub 2 using a partially ionized beam  

Energy Technology Data Exchange (ETDEWEB)

Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO{sub 2} substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio {ital I}(111)/{ital I}(200) reaches its maximum value indicating a strong {l angle}111{r angle} texture, ...

1990-05-01

44

Deposition of Cu film on SiO sub 2 using a partially ionized beam  

Science.gov (United States)

Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO{sub 2} substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio {ital I}(111)/{ital I}(200) reaches its maximum value indicating a strong {l angle}111{r angle} texture, ...

1990-05-01

45

Electro-static beam steering mechanism for a high current negative ion beam consisting of multi-beamlets  

Energy Technology Data Exchange (ETDEWEB)

An electrostatic beam steering mechanism (ESM) has been designed and tested to deflect negative ion beams consisting of multi-beamlets. A steering angle of 10 mrad was obtained within the deviation of less than 1 mrad by biasing two electrodes at 0.5 kV and -0.75 kV for 120 keV H{sup -} ion beam. The current flowing to the positive electrode was no more than 10% of the beam current at a pressure of 2.8x10{sup -5} Torr. (author)

1998-11-01

46

Reduction of transient diffusion from 1{endash}5 keV Si{sup +} ion implantation due to surface annihilation of interstitials  

Energy Technology Data Exchange (ETDEWEB)

The reduction of transient enhanced diffusion (TED) with reduced implantation energy has been investigated and quantified. A fixed dose of 1{times}10{sup 14} cm{sup {minus}2} Si{sup +} was implanted at energies ranging from 0.5 to 20 keV into boron doping superlattices and enhanced diffusion of the buried boron marker layers was measured for anneals at 810, 950, and 1050{degree}C. A linearly decreasing dependence of diffusivity enhancement on decreasing Si{sup +} ion range is observed at all temperatures, extrapolating to {approximately}1 for 0 keV. This is consistent with our expectation that at zero implantation energy there would be no excess interstitials from the implantation and hence no TED. Monte Carlo modeling and continuum simulations are used to fit the experimental data. The results are consistent with a surface recombination length for interstitials of {lt}10 nm. The data presented here demonstrate that in the ...

1997-11-01

47

Reduction of transient diffusion from 1 endash 5 keV Si"+ ion implantation due to surface annihilation of interstitials  

International Nuclear Information System (INIS)

The reduction of transient enhanced diffusion (TED) with reduced implantation energy has been investigated and quantified. A fixed dose of 1x10"1"4 cm"-"2 Si"+ was implanted at energies ranging from 0.5 to 20 keV into boron doping superlattices and enhanced diffusion of the buried boron marker layers was measured for anneals at 810, 950, and 1050 degree C. A linearly decreasing dependence of diffusivity enhancement on decreasing Si"+ ion range is observed at all temperatures, extrapolating to #approx#1 for 0 keV. This is consistent with our expectation that at zero implantation energy there would be no excess interstitials from the implantation and hence no TED. Monte Carlo modeling and continuum simulations are used to fit the experimental data. The results are consistent with a surface recombination length for interstitials of <10 nm. The data presented here demonstrate that in the range of annealing temperatures of ...

48

Novel approach towards improving decontamination factor (DF) in treatment of low level radioactive waste  

International Nuclear Information System (INIS)

The use of finely powdered ion exchange resins improve loading of specific ion exchange materials with better performance but as such these materials are not suitable for column operation. However, by proper selection of ion exchange support medium, it is possible to get better product. The radioactive solution can be treated by suspending this material, stirring and allowing to settle. The present method gives DF in the range of 70 - 80 even after repeated use as compared to DF in the range of 5 to 10 by single conventional chemical treatment process. (author)

2001-02-07

49

Effects of ion irradiation on the diffusion of pre-implanted B atoms in crystalline silicon  

International Nuclear Information System (INIS)

N-type crystalline Si (100) implanted with 5 keV B ions was subsequently irradiated with MeV Si, O and F ions. The B atom profiles were measured by means of secondary ion mass spectrometer after the treatment of rapid thermal annealing. The results show that the transient enhanced diffusion of B atoms is effectively limited by the post-implantation of high energy ions at high dose. At the same irradiation conditions, it is found that the existence of a SiO_2 layer in the near surface of Si is even more effective in suppressing the transient enhanced diffusion of the doped B atoms. The results are qualitatively discussed in combination with the analyses of RBS/c measurements and calculation of the DICADA code

2001-12-01

50

Treatment of radioactive liquid waste by reverse osmosis  

International Nuclear Information System (INIS)

The report addresses the application of reverse osmosis to the treatment of radioactive liquid waste, focusing on the effects of non-radioactive cations and anions, existing in radioactive waste, on the removal of radioactive nuclides. The bivalent cations are generally about ten times as high in decontamination factor as monovalent ones. In the case of anions, the factor of SO_4"2"- is about ten times that of Cl"- while that of NO_3"- is somewhat smaller than that of Cl"-. During permeation through membrane, anions tend to accompany cations, and the decontamination factor of accompanying ions is found to increase with that of the paring ions. These results indicate that if one can select components that will remain in the liquid waste, one should consider their effects on the efficiency of its treatment. Furthermore, the interaction between two anions or ...

51

Ion beam mixing in Fe/Si and Ta/Si bilayers: Possible effects of ion charges  

Energy Technology Data Exchange (ETDEWEB)

Thin Fe and Ta layers of 30-45 nm thickness, deposited via magnetron sputtering on Si (1 0 0) substrates, were bombarded at room temperature with 100 keV Ar{sup 1+} or Ar{sup 8+} or with 250 keV Xe{sup 1+} or Xe{sup 19+} ions in order to test the influence of the ion charge state on the surface sputtering and interface mixing. The samples were characterized by means of Rutherford backscattering at 0.9-3.0 MeV {alpha}-particle energy, time-of-flight elastic recoil detection analysis with a 53 MeV {sup 127}I{sup 10+} beam and atomic force microscopy. No influence of the charge state on the sputtering and athermal mixing rate was observed in the case of the Ta/Si system. However, in the case of the Fe/Si system, the ion charge was observed to have an influence on the mixing rate.

2003-05-01

52

Mechanism for the reduction of interstitial supersaturations in MeV-implanted silicon  

Energy Technology Data Exchange (ETDEWEB)

We demonstrate that the excess vacancies induced by a 1 MeV Si implant reduce the excess interstitials generated by a 40 keV Si implant during thermal annealing when these two implants are superimposed in silicon. It is shown that this previously observed reduction is dominated by vacancy annihilation and not by gettering to deeper interstitial-type extended defects. Interstitial supersaturations were measured using B doping superlattices (DSL) grown on a silicon-on-insulator (SOI) substrate. Implanting MeV and keV Si ions into the B DSL/SOI structure eliminated the B transient enhanced diffusion normally associated with the keV implant. The buried SiO{sub 2} layer in the SOI substrate isolates the deep interstitials-type extended defects of the MeV implant, thereby eliminating the possibility that these defects getter the interstitial excess induced by the keV Si implant. ...

1999-03-01

53

Mechanism for the reduction of interstitial supersaturations in MeV-implanted silicon  

International Nuclear Information System (INIS)

We demonstrate that the excess vacancies induced by a 1 MeV Si implant reduce the excess interstitials generated by a 40 keV Si implant during thermal annealing when these two implants are superimposed in silicon. It is shown that this previously observed reduction is dominated by vacancy annihilation and not by gettering to deeper interstitial-type extended defects. Interstitial supersaturations were measured using B doping superlattices (DSL) grown on a silicon-on-insulator (SOI) substrate. Implanting MeV and keV Si ions into the B DSL/SOI structure eliminated the B transient enhanced diffusion normally associated with the keV implant. The buried SiO_2 layer in the SOI substrate isolates the deep interstitials-type extended defects of the MeV implant, thereby eliminating the possibility that these defects getter the interstitial excess induced by the keV Si implant. copyright 1999 ...

1999-03-01

54

Effect of Al and Be ions pre-implantation on formation and growth of helium bubbles in SiC/SiC composites  

Energy Technology Data Exchange (ETDEWEB)

The effect of Al and Be ions pre-implantation on microstructural change and, the formation and growth of He bubbles in SiC/SiC composite was investigated. Four kinds of ion implanted specimens were prepared with 100 appm Al, 1000 appm Al, 100 appm Be and 1000 appm Be implanted. No microstructural change was observed in the matrices and fibers of SiC/SiC composites implanted with Al or Be ions up to 1000 appm. The un-implanted and Al or Be pre-implanted SiC/SiC composites were simultaneously irradiated to 10 dpa using triple ion-beams (6.0-MeV Si{sup 2+}, 1.0-MeV He{sup +} and 340-keV H{sup +}) at 1000 deg. C. Helium bubbles were formed in every matrix and fiber irradiated by triple ion-beams. The size of He bubbles in the matrix was increased by implanting Al or Be ions and increased with increasing amount of implanted Al or Be ...

2007-03-15

55

Effect of Al and Be ions pre-implantation on formation and growth of helium bubbles in SiC/SiC composites  

International Nuclear Information System (INIS)

The effect of Al and Be ions pre-implantation on microstructural change and, the formation and growth of He bubbles in SiC/SiC composite was investigated. Four kinds of ion implanted specimens were prepared with 100 appm Al, 1000 appm Al, 100 appm Be and 1000 appm Be implanted. No microstructural change was observed in the matrices and fibers of SiC/SiC composites implanted with Al or Be ions up to 1000 appm. The un-implanted and Al or Be pre-implanted SiC/SiC composites were simultaneously irradiated to 10 dpa using triple ion-beams (6.0-MeV Si"2"+, 1.0-MeV He"+ and 340-keV H"+) at 1000 deg. C. Helium bubbles were formed in every matrix and fiber irradiated by triple ion-beams. The size of He bubbles in the matrix was increased by implanting Al or Be ions and increased with increasing amount of implanted Al or Be ions. ...

2007-03-01

56

Steering of high energy negative ion beam and design of beam focusing/deflection compensation for JT-60U large negative ion source  

Energy Technology Data Exchange (ETDEWEB)

A large negative ion source for JT-60U produces high current ion beam from a wide extraction area of 45 cm x 110 cm. On the other hand, a cross-sectional area of the negative ion based neutral beam (NNB) injection port on JT-60U is narrow, about 50 cm x 60 cm. In order to inject the neutral beam at a high geometric efficiency, i.e. to suppress beam loss in the beamline, it is necessary to steer the beam for both compensation of undesirable beam deflection in extractor and focusing of the beam. For the JT-60U, two methods are provided for the required beam steering. Among them the results of beam steering experiment by aperture displacement and the design study are summarized in the present report. The experiment was carried out with 400 keV negative ion source, which has the three stage accelerator of similar structure as the JT-60U ion source, at Negative ...

2000-03-01

57

Pitting and intergranular corrosion resistances of nitrogen ion implanted type 304 stainless steel  

International Nuclear Information System (INIS)

Type 304 stainless steel (SS) specimens sensitised at 873 K and 973 K for 1, 10 and 100 hours respectively were ion implanted using a 150 keV accelerator at an energy of 70 keV in two different doses of nitrogen namely 1 x 10"1"6 to 1 x 10"1"7 ions/cm"2. Ion implantation at 1 x 10"1"6 ions/cm"2 did not show any improvement in pitting resistance, however, the specimens implanted at 1 x 10"1"7 ions/cm"2 showed significant increase in pitting corrosion resistance when potentiodynamic anodic polarisation studies were carried out in acidic chloride medium. For specimens aged at 873 K, nitrogen ion implantation at 1 x 10"1"6 ions/cm"2 increased the intergranular corrosion susceptibility compared to that of unimplanted specimens. However, at the dose of 1 x 10"1"7 ions/cm"2, ...

1998-05-24

58

Effect of the Ge preamorphization dose on boron diffusion and defect evolution in silicon  

Energy Technology Data Exchange (ETDEWEB)

In this paper, we study the effect of the Ge{sup +} preamorphization dose on boron diffusion and on the thermal evolution of end of range (EOR) defects during annealing. Amorphizations were carried out by implanting Ge{sup +} at 150 keV to doses ranging from 1x10{sup 15} to 8x10{sup 15} ions/cm{sup 2}. Boron was subsequently implanted at 3 keV with a dose of 1x10{sup 14} ions/cm{sup 2}. Rapid thermal annealing (RTA) was performed for various time/temperature combinations in nitrogen ambient. Secondary ion mass spectroscopy (SIMS) and transmission electron microscopy (TEM) were used to study boron diffusion and defect evolution, respectively. We have found that after a given annealing, both the defect size and boron diffusivity are independent on the Ge ion dose. Increasing this dose only results in an increase of the defect density. These results are discussed ...

2002-01-01

59

Effect of the Ge preamorphization dose on boron diffusion and defect evolution in silicon  

International Nuclear Information System (INIS)

In this paper, we study the effect of the Ge"+ preamorphization dose on boron diffusion and on the thermal evolution of end of range (EOR) defects during annealing. Amorphizations were carried out by implanting Ge"+ at 150 keV to doses ranging from 1x10"1"5 to 8x10"1"5 ions/cm"2. Boron was subsequently implanted at 3 keV with a dose of 1x10"1"4 ions/cm"2. Rapid thermal annealing (RTA) was performed for various time/temperature combinations in nitrogen ambient. Secondary ion mass spectroscopy (SIMS) and transmission electron microscopy (TEM) were used to study boron diffusion and defect evolution, respectively. We have found that after a given annealing, both the defect size and boron diffusivity are independent on the Ge ion dose. Increasing this dose only results in an increase of the defect density. These results are discussed and definitely show that EOR ...

2002-01-01

60

Depth profiling using C{sub 60} {sup +} SIMS-Deposition and topography development during bombardment of silicon  

Energy Technology Data Exchange (ETDEWEB)

A C{sub 60} {sup +} primary ion source has been coupled to an ion microscope secondary ion mass spectrometry (SIMS) instrument to examine sputtering of silicon with an emphasis on possible application of C{sub 60} {sup +} depth profiling for high depth resolution SIMS analysis of silicon semiconductor materials. Unexpectedly, C{sub 60} {sup +} SIMS depth profiling of silicon was found to be complicated by the deposition of an amorphous carbon layer which buries the silicon substrate. Sputtering of the silicon was observed only at the highest accessible beam energies (14.5 keV impact) or by using oxygen backfilling. C{sub 60} {sup +} SIMS depth profiling of As delta-doped test samples at 14.5 keV demonstrated a substantial (factor of 5) degradation in depth resolution compared to Cs{sup +} SIMS depth profiling. This degradation is thought to result from the formation of an unusual ...

2006-07-30

61

Peculiarities of Swift Proton Transmission through Tapered Glass Capillaries  

International Nuclear Information System (INIS)

A study of the 150-300 keV proton beam transmission through glass (borosilicate) tapered capillaries with different diameters of the input and output of the capillary was performed. The focusing effect was observed. The areal density of the transmitted beam is enhanced by approximately 20 times. It was shown that changing a taper angle from 0.5 deg to 1.7 deg evidences the increase of the transmission coefficient more than by 300 times keeping the initial energy spectrum of ions. (author)

2011-07-01

62

Measurement of relative L X-ray intensity ratio following radioactive decay and photoionization  

International Nuclear Information System (INIS)

The measurements of the L X-ray intensity ratio I(L?)/I(L?), I(L?)/I(L?), I(L?)/I(L?), I(L?)/I(L?) and I(L?)/I(L?) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV ?-rays from a filtered radioisotope 241Am was used, and by the radioactive decay of 160Tb, 160Er, 173Lu, 182Re, 201Tl, 203Pb and 207Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L?/L?), I(L?/L?), I(L?/L?), I(L?/L?) and I(L?/L?) intensity ratios were calculated using theoretically tabulated values of subshell photoionization cross-section, fluorescence yield, fractional X-ray emission rates, Coster-Kronig transition probabilities. It was observed that present values agree with previous theoretical and other available experimental results.

2008-05-22

63

Comparison of LaBr_3:Ce and NaI(Tl) Scintillators for Radio-Isotope Identification Devices  

International Nuclear Information System (INIS)

Lanthanum halide (LaBr_3:Ce) scintillators offer significantly better resolution (< 3% at 662 keV) relative to NaI(Tl) and have recently become commercially available in sizes large enough for the handheld, Radio-Isotope Identification Device (RIID) market. Drawbacks to lanthanum halide detectors, however, include internal radioactivity contributing to spectral counts, and a low-energy response which can cause detector resolution to be worse than that of NaI(Tl) below 100 keV. To study the potential of this new material for RIIDs we performed a series of measurements comparing a 1.5 x 1.5-inch LaBr_3:Ce detector with an Exploranium GR-135 RIID, which contains a 1.5 x 2.2-inch NaI(Tl) detector. Measurements were taken for short timeframes, as typifies RIID usage. Measurements included examples of naturally occurring radioactive material (NORM), typically found in cargo, and special nuclear materials. ...

2005-10-23

64

Characterization system for Germanium detectors dedicated to gamma spectroscopy applied to nuclear waste  

International Nuclear Information System (INIS)

CEA-Valduc produces some radioactive waste (mainly alpha emitters). Legislation requires producers to sort their waste by activity and type of isotopes, and to package them in order to forward them to the appropriate reprocessing or storage facility. Our lab LMDE (laboratory for measurements on nuclear wastes and valuation) is in charge of the characterization of the majority of waste produced by CEA-Valduc. Among non-destructive methods to characterize a radioactive object, gamma-spectroscopy is one of the most efficient. We present to this conference the method we use to characterize nuclear waste and the system we developed to characterize our germanium detectors. The goal of this system is to obtain reliable numerical models of our detectors and calculate their efficiency curves. Measurements are necessary to checks models and improve them. These measurements are made on a bench using pinpoint sources ("1"3"3Ba, "1"5"2Eu) from 60 ...

2009-06-07

65

Surface segregation and radiation hardening of 16Cr12MoWSiVNbB steel after irradiation with Ni++ and He+ ions  

British Library Electronic Table of Contents (United Kingdom)

Irradiation of EP-823 (16Cr12MoWsiVNbB) ferritic-martensitic steel with 7-MeV Ni++ ions and with 30- and 70-keV He+ ions at a temperature of 500?C was followed by an increase in the microhardness, which was due to both radiation point defects and changes in the phase composition and the dislocation structure of the steel. It was found that the dependence of the largest relative increase in the microhardness on the concentration of radiation-induced point defects in the near-surface region of the steel under irradiation with different ions correlated with an analogous dependence of the surface segregation of silicon and chromium.

2011-01-01

66

Focused ion beam preparation of inclined planes in semiconductor materials  

International Nuclear Information System (INIS)

Focused ion beam (FIB) micromachining has been used to produce inclined planes on semiconductor surfaces. A 10 keV FIB system, utilising a Ga"+ liquid metal ion source (LMIS), was employed. The ramped surfaces were prepared by digitally deflecting the ion beam in a serpentine fashion over a rectangular area and incrementing the time the beam spends at a pixel, dwell time, line by line. For the conditions used, control in micromachining the inclination of the ramps to the starting horizontal surface is of the order of 1 arc s per scan of the FIB over the area of interest. The possibility of using such surfaces prepared by FIB, along with vacuum growth techniques such as molecular beam epitaxy (MBE), for application to strain relief structures and lateral device production is discussed. (author).

67

Electrical properties of focused-ion-beam boron-implanted silicon  

International Nuclear Information System (INIS)

Electrical properties of 16 keV, focused-ion-beam (FIB) (beam diameter: 1 #mu#m, current density: 50 mA/cm"2) boron-implanted silicon layers have been investigated as a function of beam scan speed and ion dose, and compared with those obtained by conventional implantation (current density: 0.4 #mu#A/cm"2). High electrical activation of the FIB implanted layers is obtained by annealing below 800"0C as a result of the increase in amorphous zones created in the implanted layers. Amorphous zone overlapping is assumed to occur at FIB implantation doses of 3 - 4 x 10"1"5 ions/cm"2 from the results of electrical activation and the carrier profile of implanted regions annealed at low temperature, if beam scan speed is lowered to about 10"-"2 cm/s. (author).

68

Effects on focused ion beam irradiation on MOS transistors  

Energy Technology Data Exchange (ETDEWEB)

The effects of irradiation from a focused ion beam (FIB) system on MOS transistors are reported systematically for the first time. Three MOS transistor technologies, with 0.5, 1, and 3 {mu}m minimum feature sizes and with gate oxide thicknesses ranging from 11 to 50 nm, were analyzed. Significant shifts in transistor parameters (such as threshold voltage, transconductance, and mobility) were observed following irradiation with a 30 keV Ga{sup +} focused ion beam with ion doses varying by over 5 orders of magnitude. The apparent damage mechanism (which involved the creation of interface traps, oxide trapped charge, or both) and extent of damage were different for each of the three technologies investigated.

1997-04-01

69

Channeling studies of radiation damage in metal-silicides  

Science.gov (United States)

Channeling effect measurements have been employed to investigate radiation damage produced by 100-keV Ar ions in preferred oriented polycrystalline metal-silicide layers, such as Pd/sub 2/Si and NiSi/sub 2/ layers formed on single-crystalline Si. For room-temperature implantation, an amount of the damage in Pd/sub 2/Si layers was found to saturate at doses between 3 x 10/sup 14/ and 1 x 10/sup 17/ ions/cm/sup 2/, where the minimum aligned yield of 1.5-MeV He ions was nearly 40% of the random one. On the contrary, it was observed that the NiSi/sub 2/ layers became amorphous at doses higher than 3 x 10/sup 15/ ions/cm/sup 2/. These results were confirmed by the reflection electron diffraction analyses.

1978-01-01

70

Channeling studies of radiation damage in metal-silicides  

International Nuclear Information System (INIS)

Channeling effect measurements have been employed to investigate radiation damage produced by 100-keV Ar ions in preferred oriented polycrystalline metal-silicide layers, such as Pd_2Si and NiSi_2 layers formed on single-crystalline Si. For room-temperature implantation, an amount of the damage in Pd_2Si layers was found to saturate at doses between 3 x 10"1"4 and 1 x 10"1"7 ions/cm"2, where the minimum aligned yield of 1.5-MeV He ions was nearly 40% of the random one. On the contrary, it was observed that the NiSi_2 layers became amorphous at doses higher than 3 x 10"1"5 ions/cm"2. These results were confirmed by the reflection electron diffraction analyses.

71

Angular scattering in electron capture and loss D/sup -/ beam formation processes  

Energy Technology Data Exchange (ETDEWEB)

The development of high energy (> 150 keV) neutral beams for heating and fueling magnetic fusion devices depends on the ability to produce well-collimated negative ion beams. The double capture charge-exchange technique is a known, scalable method. In order to maximize the overall efficiency of the process and to achieve the desired beam characteristics, it is necessary to examine the optical qualities of the beams as well as the total efficiency of beam production. A combined modeling and experimental study of the angular scattering effects in negative ion formation and loss processes has therefore been undertaken.

1980-01-01

72

Alignment accuracy of focused ion beam implantation  

Energy Technology Data Exchange (ETDEWEB)

The theoretical alignment limit for focused ion beam (FIB) implantation was deduced from the calculated resolution for the detection of an alignment mark. The alignment resolution varies with the signal to noise ratio and there is an optimum current which gives the best resolution. The alignment resolution epsilon/sub sigma/ is approximately 0.006 ..mu..m for a 160 keV Si/sup ++/ beam from our FIB implanter. The measured alignment error is approximately 0.06 ..mu..m and the main reason of this discrepancy is vibration. The ultimate limit on the alignment error can be reached through improvements in the implanter system.

1987-06-01

73

LUCIFER, a potentially background-free approach to the search for neutrinoless double beta decay  

British Library Electronic Table of Contents (United Kingdom)

LUCIFER (Low-background Underground Cryogenic Installation For Elusive Rates) is a new project for the study of neutrinoless Double Beta Decay, based on the technology of scintillating bolometers. These devices promise a very efficient rejection of the alpha background, opening the way to a virtual background-free experiment if candidates with a transition energy higher than 2615 keV are investigated. The baseline candidate for LUCIFER is 82Se. This isotope will be embedded in ZnSe crystals grown with enriched selenium and operated as scintillating bolometers in a low-radioactivity underground dilution refrigerator. In this paper, the LUCIFER concept will be introduced. The sensitivity and the very promising prospects related to this project will be discussed.

2011-01-01

74

Study on the use of zirconium phosphate for radioactive waste treatment  

International Nuclear Information System (INIS)

Zirconium phosphate was one of the earliest inorganic ion-exchange suggested for removing strontium and cesium from aqueous nuclear waste. This paper studied ionic exchange to remove Cs-137 and Sr-90 by using different cationic of zirconium phosphate. In this case the parameters studied were the effect of temperature and ion concentration to percent up take and distribution coefficients. It is also conducted the study on column experiments to determine the breakthrough curves for Cs-137 and Sr-90. The result showed the potential of use of zirconium phosphate in radioactive waste treatment. (author)

1998-12-01

75

Applications of the Long-Range Alpha Detector (LRAD) technology to low-level radioactive waste management  

Energy Technology Data Exchange (ETDEWEB)

Long-Range Alpha Detector (LRAD) systems are designed to monitor alpha contamination by measuring the number of ions in the air. Alpha particles are a form of ionizing radiation and a typical 5-MeV alpha particle will create about 150,000 ion pairs in air. Field tests at various DOE sites have shown that LRAD Surface Soil Monitors (SSM), Sample Monitors, and Object Monitors are faster and more sensitive than traditional alpha detectors for measuring alpha contamination. This paper discusses the various applications of LRAD technology to low-level radioactive waste management.

1993-12-01

77

Removal of radioactive ions from nuclear waste solutions by electrodialysis  

International Nuclear Information System (INIS)

Removal of radioactive ions was studied from low and medium level radioactive waste solutions by electrodialysis using ion exchange membranes. The test solutions contained "1"3"7Cs"+, "1"0"6Ru"3"+ or fission products (F.P.) as active ions and NaCl, Na_2SO_4 or Ca(NO_3)_2 as inactive coexisting salts. The decontamination factor of the active ions was in the order: "1"3"7Cs"+ (greater than 99%) > "9"0Sr"2"+ > F.P. > "1"0"6Ru"3"+. The dialysis time required to attain the saturation was the shortest for monovalent cations K"+, Cs"+ and Na"+, intermediate for divalent cation Sr"2"+, and the longest for trivalent cation Ru"3"+. The ratio of the decontamination factor of an active ion eta sub( a) to the desalination factor of an inactive ion eta sub( b) was nearly equal to unity for "2"4Na, "4"2K, "1"3"7Cs and "9"0Sr. ...

78

Sodium to sodium carbonate conversion process  

Energy Technology Data Exchange (ETDEWEB)

A method is described for converting radioactive alkali metal into a low level disposable solid waste material. The radioactive alkali metal is atomized and introduced into an aqueous caustic solution having caustic present in the range of from about 20 wt % to about 70 wt % to convert the radioactive alkali metal to a radioactive alkali metal hydroxide. The aqueous caustic containing radioactive alkali metal hydroxide and CO{sub 2} are introduced into a thin film evaporator with the CO{sub 2} present in an amount greater than required to convert the alkali metal hydroxide to a radioactive alkali metal carbonate, and thereafter the radioactive alkali metal carbonate is separated from the thin film evaporator as a dry powder. Hydroxide solutions containing toxic metal hydroxide including one or more metal ions of Sb, As, ...

1997-10-14

79

Correlation between ion beam parameters and physical characteristics of nanostructures fabricated by focused ion beam  

International Nuclear Information System (INIS)

We report a study of the physical characteristics of the pillars of C, Pt and W grown by 10-30 keV Ga focused ion beam (FIB) as a function of Ga ion flux, and present a quantitative analysis of the elements using energy-dispersive analysis of X-rays (EDAX). All the FIB grown pillars exhibit a rough morphology with whisker like protrusions on the cylindrical surface and broadening of the base as compared to the nominal size. For a constant fluence, the height of the pillar initially increases and then reduces after going through a maximum as a function of ion flux in all the cases. The compositional analysis shows good metallic quality for Pt structures but reveals significant contamination of Ga in C and Ga and C in W structures at higher ion fluxes. Explanation to all these observations has been sought in the light of secondary ion and electron effects and the ...

2008-04-01

80

Microprobe RBS analysis of localized processed areas by FIB etching and deposition  

International Nuclear Information System (INIS)

Localized beam-processed areas using chemical reactions induced by a 30 keV Ga"+ focused ion beam (FIB) with and without I_2 (etching) and (CH_3)_3CH_3C_5H_5Pt gases (Pt deposition) have been analyzed using a 300 keV Be"2"+ microprobe with a beam spot size of 50-80 nm. The analyzed results have been compared with energy dispersive X-ray (EDX) analysis using an electron beam. The EDX analysis only indicated incorporated impurities at high fluence such as Ga, Pt and C, while microprobe RBS analysis could detect residual iodine with low concentration which couldn't be detected by EDS analysis because of the lower sensitivity of the EDX analysis for heavy atoms.

2001-07-01

81

Atomic scale models of Ion implantation and dopant diffusion in silicon  

Energy Technology Data Exchange (ETDEWEB)

We review our recent work on an atomistic approach to the development of predictive process simulation tools. First principles methods, molecular dynamics simulations, and experimental results are used to construct a database of defect and dopant energetics in Si. This is used as input for kinetic Monte Carlo simulations. C and B trapping of the Si self- interstitial is shown to help explain the enormous disparity in its measured diffusivity. Excellent agreement is found between experiments and simulations of transient enhanced diffusion following 20-80 keV B implants into Si, and with those of 50 keV Si implants into complex B-doped structures. Our simulations predict novel behavior of the time evolution of the electrically active B fraction during annealing.

1999-03-01

82

Temperature measurement of 6He?+? ions confined in a transparent Paul trap  

British Library Electronic Table of Contents (United Kingdom)

The LPCTrap setup is a transparent Paul trap dedicated to the measurement of the ??? correlation coefficient a ?? in the ? decay of trapped radioactive nuclides. In a first experiment, the system has been used to record ?105 coincidences between the ? particles and recoiling ions emitted from the decay of 6He?+? ions. The analysis of the collected data has already shown that the size of the 6He?+? ion cloud confined in the Paul trap is a critical parameter, potentially limiting the accuracy on the a ?? measurement. We report here the precise determination of the trapped ion cloud temperature and size. This was performed by extracting the trapped ions toward a position sensitive micro channel plate detector at different phases of the RF driving field. We find a temperature T exp ?= 0.107(7)...

2011-01-01

83

Oxygen-concentration dependent enhancement of positive secondary ion emission from silicon  

Energy Technology Data Exchange (ETDEWEB)

The enhancement of positive secondary ion yields of silicon due to the presence of oxygen has been investigated quantitatively by low-energy (5 keV) oxygen implantation. Implantation and sputter profiling with 9 keV In/sup +/ were performed in the same ion microprobe instrument. Depth profiles of substrate and implanted oxygen atoms were measured for fluences ranging from 5x10/sup 15/ to 4x10/sup 16/ O-atoms/cm/sup 2/. The oxygen concentration, c(O), in the sample was deduced from the implanted fluence and the range distribution in the Gaussian approximation. It was found that the oxygen-enhanced Si/sup +/ intensity is proportional to c(O)sup(x) (with x=1.4) in the concentration regime, 1.5<=c(O)<=30 at%. The O/sup +/ intensity shows a similar dependence for c(O)> or approx.20 at.%.

1983-12-15

84

Hardness and defect structures in EC316LN austenitic alloy irradiated under a simulated spallation neutron source environment using triple ion-beams  

Energy Technology Data Exchange (ETDEWEB)

For an assessment of the future US spallation neutron source (SNS) target performance, radiation induced hardening and microstructural evolution were investigated as a function of ion dose for EC316LN stainless steel. Irradiation was carried out using 3.5 MeV Fe{sup +}, 360 keV He{sup +}, and 180 keV H{sup +} simultaneous ion-beams at 200 deg. C to simulate the damage, He and H production in the SNS target vessel wall. At low dose (< 1 dpa), the predominant defects were black dots whose number density saturated rapidly within a few dpa. This was followed by the evolution of interstitial loops whose number density saturated below 15 dpa. Although He-bubbles were not visible, severely scalloped loops suggested that the implanted He/H atoms existed in the form of small clusters. Comparison with reported neutron irradiation data showed that hardening and ductility loss occurred mostly in the black ...

2000-04-01

85

Hardness and defect structures in EC316LN austenitic alloy irradiated under a simulated spallation neutron source environment using triple ion-beams  

International Nuclear Information System (INIS)

For an assessment of the future US spallation neutron source (SNS) target performance, radiation induced hardening and microstructural evolution were investigated as a function of ion dose for EC316LN stainless steel. Irradiation was carried out using 3.5 MeV Fe"+, 360 keV He"+, and 180 keV H"+ simultaneous ion-beams at 200 deg. C to simulate the damage, He and H production in the SNS target vessel wall. At low dose (< 1 dpa), the predominant defects were black dots whose number density saturated rapidly within a few dpa. This was followed by the evolution of interstitial loops whose number density saturated below 15 dpa. Although He-bubbles were not visible, severely scalloped loops suggested that the implanted He/H atoms existed in the form of small clusters. Comparison with reported neutron irradiation data showed that hardening and ductility loss occurred mostly in the black dot regime (< 1 ...

2000-04-01

86

Triple ion-beam studies of radiation damage effects in a 316LN austenitic alloy for a high power spallation neutron source  

Energy Technology Data Exchange (ETDEWEB)

Austenitic 316LN alloy was ion-irradiated using the unique Triple Ion Beam Facility (TIF) at ORNL to investigate radiation damage effects relevant to spallation neutron sources. The TIF was used to simulate significant features of GeV proton irradiation effects in spallation neutron source target materials by producing displacement damage while simultaneously injecting helium and hydrogen at appropriately high gas/dpa ratios. Irradiations were carried out at 80, 200, and 350 C using 3.5 MeV Fe{sup ++}, 360 keV He{sup +}, and 180 keV H{sup +} to accumulate 50 dpa by Fe, 10,000 appm of He, and 50,000 appm of H. Irradiations were also carried out at 200 C in single and dual ion beam modes. The specific ion energies were chosen to maximize the damage and the gas accumulation at a depth of {approximately} 1 {micro}m. Variations in microstructure and hardness of ...

1997-09-01

87

Self-diffusion of silicon in thin films of cobalt, nickel, palladium and platinum silicides  

International Nuclear Information System (INIS)

Radioactive "3"1Si was used as a tracer to study silicon self-diffusion in thin film silicides of cobalt, nickel, palladium and platinum. The specimens were prepared by sequential electron beam evaporation of radioactive "3"1Si and of the metal onto cleaned silicon wafers. By vacuum annealing at the appropriate formation temperature a silicide about 250 nm thick containing a sharp radioactive band about 50 nm thick was generally formed. Subsequent heating above the formation temperature resulted in a spreading of the activity owing to silicon self-diffusion. Activity profiles in the silicides were measured by a combination of ion beam sputtering, radioactivity counting and Rutherford backscattering of charged nuclear particles. (orig.).

88

The effect of ion implantation of Ar on the aqueous corrosion resistance of Zr-4 alloy  

International Nuclear Information System (INIS)

The effect of ion implantation on the aqueous corrosion resistance of Zr-4 in deaerated 1N H_2SO_4 was studied with the potentiokinetic technique. The Zr-4 alloy was bombarded with 5x10"1"4-2x10"1"6 Ar/cm"2 of 190 keV. It was found that the passive current density of Zr-4 decreases with increasing implantation dose. Photoelectrochemical results show that the ion implantation of Ar in Zr-4 raises the flatband potential of its passive film. AES was employed to analyze the surface of the passive film of Zr-4. The decrease in passive current density may be attributed to a thickening oxide layer on Zr-4 and a decrease in concentration of oxygen vacancies in its passive film. ((orig.)).

89

Technique for generating atomic negative ion beams of the group IA elements  

Energy Technology Data Exchange (ETDEWEB)

A technique has been developed which enables the direct sputter generation of atomic negative ion beams of all members of the Group IA elements (Li, Na, K, Rb and Cs). The method is based on the use of sputter samples formed by pressing mixtures of the carbonates of the Group IA elements and 10% (atomic) Cu, Ag or other metal powders. The following intensities are typical of those observed from carbonate samples subjected to approx. = 3 keV cesium ion bombardment: Li/sup -/: greater than or equal to 0.5 ..mu..A; Na/sup -/: greater than or equal to 0.5 ..mu..A; K/sup -/: greater than or equal to 0.5 ..mu..A; Rb/sup -/: greater than or equal to 0.5 ..mu..A; Cs/sup -/: greater than or equal to 0.2 ..mu..A.

1989-03-15

90

Simulation study on retention and reflection from tungsten carbide under high fluence of helium ions  

Energy Technology Data Exchange (ETDEWEB)

We have studied, by a Monte Carlo simulation code ACAT-DIFFUSE, the fluence-dependence of the amount of retained helium atoms in tungsten carbide at room temperature under helium ion bombardment. The retention behavior may be understood qualitatively in terms of irradiation-dependent diffusion coefficient assumed and range. The emission processes from tungsten carbide under helium ion irradiation derived were compared with each other. We have discussed the retention curves for incident energy of 5 keV at incident angles of 0deg and 80deg and of 500 eV at 0deg. The energy spectra of helium atoms reflected from tungsten carbide for incident energy of 500 eV at 0deg and 80deg were compared with those from graphite and tungsten. (author)

2000-08-01

91

RHEED, AES and XPS studies of the passive films formed on ion implanted stainless steel  

International Nuclear Information System (INIS)

P-implantation (10"1"7 ions cm"-"2, 40 KeV) into 304 stainless steel (ss) has been carried out, and an amorphous surface alloy was formed. Polarization studies in deaerated 1N H_2SO_4+ 2% NaCl showed that P-implantation improved both the general and localized corrosion resistance of 304 ss. A comparative study has been carried out between the implanted and unimplanted steel to determine what influence P-implantation has upon the properties of the passive film formed 1N H_2SO_4. The influence of Cl ions on pre-formed passive films was also studied. RHEED, XPS and AES were used to evaluate the nature of the passive films formed in these studies.

2005-05-26

92

RHEED, AES and XPS studies of the passive films formed on ion implanted stainless steel  

Energy Technology Data Exchange (ETDEWEB)

P-implantation (10/sup 17/ ions cm/sup -2/, 40 KeV) into 304 stainless steel (ss) has been carried out, and an amorphous surface alloy was formed. Polarization studies in deaerated 1N H/sub 2/SO/sub 4/+ 2% NaCl showed that P-implantation improved both the general and localized corrosion resistance of 304 ss. A comparative study has been carried out between the implanted and unimplanted steel to determine what influence P-implantation has upon the properties of the passive film formed 1N H/sub 2/SO/sub 4/. The influence of Cl ions on pre-formed passive films was also studied. RHEED, XPS and AES were used to evaluate the nature of the passive films formed in these studies.

1981-12-01

93

Photosensitivity and imaging characteristics of ion-implanted PLZT ceramics  

International Nuclear Information System (INIS)

We reported in previous papers that both the near-uv and the visible photosensitivities of ferroelectric-phase PLZT (lead lanthanum zirconate titanate) ceramics are increased by as much as four orders of magnitude by ion implantation or a combination of thermal diffusion of Al and ion implantation. New results are presented here on high-energy (1 MeV) implants of Al and Ni and coimplants of Al + Ne and Ni + Ne, and these results are compared with earlier 500 keV implants of Al and Cr and coimplants of Al + Ne and Cr + Ne as surface modification techniques for increasing the visible photosensitivity of PLZT. The important role of grain size in determining optimum contrast and resolution of stored optical information is described in terms of new experimental results.

1985-08-12

94

Investigation on corrosion resistance of amorphous films prepared by ion beam mixing  

International Nuclear Information System (INIS)

Fe-Cr amorphous films have been formed by both in situ evaporation of multilayered films and ion beam mixing in a target chamber of a 200 keV implanter. The effects of Cr content and ion irradiation on the amorphization of films were examined by transmission electron microscope (TEM). Corrosion of film was investigated by means of a potential dynamic polarization. Corrosion resistance of amorphous film in 0.5 mol H-2SO-4 solution is considerably increased than that of pure iron. Using X ray photoelectron spectroscopy (XPS) corrosion resistance in atmosphere of amorphous Fe-Cr passive films formed by P"+ mixing was studied. Results show that the richness of Cr and P exist at the surface of Fe-Cr film.

1991-01-01

95

Characterization of focused-ion-beam-induced damage in n-type silicon using Schottky contact  

International Nuclear Information System (INIS)

The effects of focused-ion-beam-induced damage on electrical properties of n-type Si are investigated by Schottky contacts. Crystalline Si is exposed to 10-30 keV focused ion beam (FIB), followed by Pt deposition under vacuum of 4x10"-"4 Pa. From current-voltage-temperature measurements, barrier heights of the Schottky contacts are found to increase almost linearly as the FIB energy increases, with the maximum increment of 0.29 eV. The increase is suggested to be related to the arising of acceptorlike defects and an amorphous layer due to FIB damages. A theoretical model is set up to quantitatively describe the barrier height changes.

2006-04-10

96

Atomic processes in high temperature plasmas  

International Nuclear Information System (INIS)

Much theoretical and experimental efforts have been expended in recent years to study those atomic processes which are specially relevant to understanding high temperature laboratory plasmas. For magnetically confined fusion plasmas, the temperature range of interest spans from the hundreds of eV at plasma edges to 10 keV at the center of the plasma, where most of the impurity ions are nearly fully ionized. These highly stripped ions interact strongly with electrons in the plasma, leading to further excitation and ionization of the ions, as well as electron capture. Radiations are emitted during these processes, which easily escape to plasma container walls, thus cooling the plasma. One of the dominant modes of radiation emission has been identified with dielectronic recombination. This paper reviews this work.

1990-01-01

97

Ar/sup +/ ion beam induced silicide formation mechanism at the Pf-Si interface  

Energy Technology Data Exchange (ETDEWEB)

Evaporated palladium films of 45 nm thickness on Si(111) were irradiated using 78 keV Ar/sup +/ ions with doses in the range of 1 x 10/sup 15/ to 1.5 x 10/sup 16/ cm/sup -2/ for the purpose of studying silicide formation. Rutherford backscattering analysis shows that intermixing has occurred across the Pd-Si interface at room temperature. The mixing behaviour increases with increasing dose of the bombarding ions, which agrees well with a theoretical model of isotropic cascade mixing for palladium, and radiation-enhanced diffusion associated with an interstitial mechanism for silicon.

1989-01-01

98

Soft X-ray holography of FIB nanostructured Co/Pt multilayers  

International Nuclear Information System (INIS)

Focused Ion Beam (FIB) milling is a powerful tool to produce ordered magnetic nanostructures. However, it is impossible to produce out-of-plane magnetized nanoscale structures from multilayer films by direct FIB writing. Co/Pt multilayers exhibit an out-of-plane easy axis due to strong perpendicular interface anisotropy. The interface contribution is known to be very sensitive to high energy ion irradiation. In case of 30 keV Ga ions it needs less than one ion per 100 surface atoms to destroy the perpendicular interface anisotropy. We demonstrate how this problem can be overcome by milling a Co/Pt multilayer, which has been deposited on a SiN membrane, from the rear side, through the SiN. The effect of the ions is determined as a function of applied dose utilizing the domain structure imaged by soft X-ray holography. When the magnetic material is removed we find ...

2009-03-22

99

A comparison and study for the processing ability of liquid radioactive waste using ion-exchange demineralizer and evaporator  

International Nuclear Information System (INIS)

Most of the low-level liquid radioactive wastes generated from PWR plants are classified into high or low total suspended solid(HTDS or LTDS), radio-chemical waste and radioactive laundry waste. Although the evaporation process has a high decontamination ability, it has several problems such as corrosion, foaming, and congestion. A new liquid waste disposal process using the ion-exchange demineralizer(IED) has been introduced into the Yonggwang NPP 5 and 6 to complement the current evaporation process. To determine the differences, these two methods have been compared in this study. Those aspects compared here were the released radioactivity volume of the liquid radioactive wastes, The dose of off-site residents, the decontamination factor, and the amount of the solid radioactive wastes. While it was expected that the liquid radioactive ...

2003-11-05

100

Microfabrication processes for high-T sub c superconducting films  

Energy Technology Data Exchange (ETDEWEB)

Microfabrication processes for Y-Ba-Cu-O films have been investigated, using ion-beam techniques. High-{Tc} superconducting lines as narrow as 0.8 {mu}m have been fabricated from epitaxial YBa{sub 2}Cu{sub 3}O{sub 7 {minus} {ital y}} films by Ar ion-beam etching (IBE), combined with focused ion-beam (FIB) lithography. The resulting lines, 1.3 {mu}m wide and 2 mm long, showed a zero resistance temperature of 81 K and a critical current density of 1.9 {times} 10{sup 4} A/cm{sup 2} at 77.3 K. Maskless etching was carried out using 130-keV au{sup +} focused ion-beam (FIB) with a 0.1-{mu}m-diameter beam. A 50-nm-thick film was patterned into 0.3-{mu}m-wide lines at a dose of 5 {times} {sup 16} ions/cm{sup 2}. In comparison with Ar IBE, Cl{sub 2} reactive ion-beam etching (RIBE) exhibited an enhancement effect in sputtering yield. ...

1989-12-01

101

Radioactive targets for neutron-induced cross section measurements  

Science.gov (United States)

Measurements using radioactive targets are important for the determination of key reaction path ways associated with the synthesis of the elements in nuclear astrophysics (sprocess), advanced fuel cycle initiative (transmutation of radioactive waste), and stockpile stewardship. High precision capture cross-section measurements are needed to interpret observations, predict elemental or isotopical ratios, and unobserved abundances. There are two new detector systems that are presently being commissioned at Los Alamos National Laboratory for very precise measurements of (n,{gamma}) and (n,f) cross-sections using small quantities of radioactive samples. DANCE (Detector for Advanced Neutron-Capture Experiments), a 4 {pi} gamma array made up of 160 BaF{sub 2} detectors, is designed to measure neutron capture cross-sections of unstable nuclei in the low-energy range (thermal to {approx}500 keV). The high ...

2004-01-01

102

Determination of the Integral/SPI instrumental response and his application to the observation of gamma ray lines in the Vela region; Determination de la reponse instrumentale du spectrometre INTEGRAL/SPI et application a l'observation des raies gamma de la region des Voiles  

Energy Technology Data Exchange (ETDEWEB)

The INTEGRAL/SPI spectrometer was designed to observe the sky in the energy band of 20 keV to 8 MeV. The specificity of instrument SPI rests on the excellent spectral resolution (2.3 keV with 1 MeV) of its detecting plan, composed of 19 cooled germanium crystals; covering an effective area of 508 cm{sup 2}. The use of a coded mask, located at 1.7 m above the detection plan ensures to it a resolving power of 2.5 degrees. The aim of this thesis, begun before the INTEGRAL launch, is made up of two parts. The first part relates to the analysis of the spectrometer calibration data. The objective was to measure and check the performances of the telescope, in particular to validate simulations of the INTEGRAL/SPI instrument response. This objective was successfully achieved. This analysis also highlights the presence of a significant instrumental background noise. Whereas, the second part concentrates on the data analysis of the Vela region ...

2005-01-15

103

The Comparison on Treatment Method of Liquid Radioactive Waste in Yonggwang No 3 and 4 and No 5 and 6  

International Nuclear Information System (INIS)

Most of the low-level liquid radioactive wastes generated from PWR plants are classified into high or low total suspended solid(HTDS or LTDS), and into radiochemical and radioactive laundry waste. Although the evaporation process has a high decontamination ability, it has several problems such as corrosion, foam, and congestion. A new liquid waste disposal process using the ion-exchange demineralizer(IED), instead of the current evaporation process, has been introduced into the Yonggwang NPP No 5 and 6. These two methods have been compared to understand the differences in this study. Aspects compared here were the released radioactivity amount of the liquid radioactive wastes, the dose of off-site residents, the decontamination factor, and the amount of the solid radioactive wastes. The IED system is designed to discharge higher ...

2004-09-01

104

The effect of preamorphization energy on ultrashallow junction formation following ultrahigh-temperature annealing of ion-implanted silicon  

International Nuclear Information System (INIS)

High-power arc lamp design has enabled ultrahigh-temperature (UHT) annealing as an alternative to conventional rapid thermal processing (RTP) for ultrashallow junction formation. The time duration of the UHT annealing technique is significantly reduced from those obtained through conventional RTP. This difference in time may offer the ability to maintain a highly activated ultrashallow junction without being subjected to transient enhanced diffusion (TED), which is typically observed during postimplant thermal processing. In this study, two 200-mm (100) n-type Czochralski-grown Si wafers were preamorphized with either a 48- or a 5-keV Ge"+ implant to 5x10"1"4 cm"2, and subsequently implanted with 3-keV BF_2"+ molecular ions to 6x10"1"4 cm"2. The wafers were sectioned and annealed under various conditions in order to investigate the effects of the UHT annealing technique on the resulting junction characteristics. The main ...

2005-02-15

105

The effect of boron implant energy on transient enhanced diffusion in silicon  

Energy Technology Data Exchange (ETDEWEB)

Transient enhanced diffusion (TED) of boron in silica after low energy boron implantation and annealing was investigated using boron-doping superlattices (DSLs) grown by low temperature molecular beam epitaxy. Boron ions were implanted at 5, 10, 20, and 40 keV at a constant dose of 2{times}10{sup 14}/cm{sup 2}. Subsequent annealing was performed at 750{degree}C for times of 3 min, 15 min, and 2 h in a nitrogen ambient. The broadening of the boron spikes was measured by secondary ion mass spectroscopy and simulated. Boron diffusivity enhancement was quantified as a function of implant energy. Transmission electron microscopy results show that {l_angle}311{r_angle} defects are only seen for implant energies {ge}10 keV at this dose and that the density increases with energy. DSL studies indicate the point defect concentration in the background decays much slower when {l_angle}311{r_angle} defects are ...

1997-02-01

106

Corrosion behaviour of molybdenum-implanted stainless steel  

Energy Technology Data Exchange (ETDEWEB)

A low-molybdenum austenitic stainless steel (UNS S30100) has been surface implanted with molybdenum ions, using various doses of 50 keV and 140 keV ions at room temperature. It is found that in aqueous sulphate/chloride solutions similar to the constitution of sea-waters the implantation does not affect the potentiostatically-determined critical pitting potential, but does change the density and morphology of corrosion pits. Pitting initiation after the addition of chloride at a fixed potential indicates little change in the time for measurable current increase, but the rate of increase of the current is much lower for implanted material. Detailed examination using optical microscopy, scanning electron microscopy, transmission electron microscopy and selected area diffraction suggests that the pits produced in implanted material are hemispherical with smooth covers of unattacked alloy. The use of ...

1990-01-01

107

Corrosion behaviour of molybdenum-implanted stainless steel  

International Nuclear Information System (INIS)

A low-molybdenum austenitic stainless steel (UNS S30100) has been surface implanted with molybdenum ions, using various doses of 50 keV and 140 keV ions at room temperature. It is found that in aqueous sulphate/chloride solutions similar to the constitution of sea-waters the implantation does not affect the potentiostatically-determined critical pitting potential, but does change the density and morphology of corrosion pits. Pitting initiation after the addition of chloride at a fixed potential indicates little change in the time for measurable current increase, but the rate of increase of the current is much lower for implanted material. Detailed examination using optical microscopy, scanning electron microscopy, transmission electron microscopy and selected area diffraction suggests that the pits produced in implanted material are hemispherical with smooth covers of unattacked alloy. The use of ...

1989-09-01

108

Micro and nano patterning by focused ion beam enhanced adhesion  

International Nuclear Information System (INIS)

We report a new method of generating nano and micro patterns using focused ion beam (FIB) induced adhesion. The method utilizes selective irradiation of thin metallic films grown on substrates by focused ion beam followed by peel off. After peel off of the irradiated thin film it is observed that the ion beam scanned portions are retained on the substrate, creating nano and micro patterns. The method is suitable for materials of which the adhesion to the substrate can be improved by ion bombardment. The phenomenon has been demonstrated by creating gold nano patterns of different shapes and sizes ranging from 500 nm to 5 #mu#m on SiO_2-Si substrate using 10-30 keV Ga FIB at beam currents up to 10 pA. The mechanism involved in the process has been discussed. The technique could be utilized to prepare micro and nano patterns of thin films deposited on an appropriate substrate for ...

2009-05-01

109

CoSi_2 nanostructures by writing FIB ion beam synthesis  

International Nuclear Information System (INIS)

A mass separated focused ion beam (FIB) is a very useful tool to fabricate nanostructures by writing implantation within an ion beam synthesis process. In these investigations the IMSA-OrsayPhysics FIB, equipped with a Co_3_6Nd_6_4 alloy liquid metal ion source, was applied. Si(100) and (111) wafers were implanted with 60 keV Co"+"+ ions in the dose range of 2 . 10"1"6 to 2 . 10"1"7 cm"-"2. Implantation parameters were investigated, like pixel dwell time, relaxation time (time between two cycles), dose rate as well as the pixel overlapping factor. The subsequent annealing was done in a two step process, namely 600 deg. C for 60 min and 1000 deg. C for 30 min in a N_2 ambient. The results obtained by SEM investigations in terms of continuous nanowire structures following the direction and interrupted CoSi_2 pattern in the direction show a clear dependence on the time scale as well ...

2006-07-01

110

Study of penetration depth for V"+ with low energy implanted in peanut seeds  

International Nuclear Information System (INIS)

The penetration depth and concentration distribution for vanadium ions with low energy implanted into the dry peanut seeds is determined by scanning electron microscope and X-ray energy dispersion spectrometer. The results show that the depth-concentration distribution is a Gaussian distribution with a long tail and the maximum penetration depth is about 13.6 #mu#m for V"+ with 200 keV in cotyledon of the peanut. The experimental result of the implanted V"+ range in the peanut seeds is compared with the calculating value of the TRIM95

2002-11-01

111

Studies of Plasma Confinement in GOL-3 Multi-mirror Trap  

International Nuclear Information System (INIS)

Recent results of the experiments at GOL-3 facility are presented. Plasma with a density of 1014...1016 cm-3 is confined in a 12-meter-long solenoid, which comprises 55 corrugation cells with mirror ratio Bmax/B min=4.8/3.2 T. The plasma is heated up to 2...4 keV temperature by a high power relativistic electron beam (?1 MeV, ? 330 kA, ?8?s, ?120 kJ) injected through one of the ends. Mechanism of experimentally observed fast ion heating, issued of plasma stability and confinement are discussed.

2006-01-01

112

Solid-state ozone synthesis by energetic ions  

International Nuclear Information System (INIS)

We have synthesized ozone by irradiating thin solid films of oxygen and oxygen-water mixtures with 100 keV protons, motivated by recent reports of condensed O_3 on icy satellites in the outer Solar system. We measured the depth of the Hartley absorption band in the ultraviolet by reflectance spectroscopy and used it to quantify the column density of ozone. We analyzed the results using a three-component (O, O_2 and O_3) model that successfully explains the fluence dependence of ozone production.

1999-08-02

113

Performance estimates of photoneutralized negative-ion beams  

Energy Technology Data Exchange (ETDEWEB)

Recent studies have provided data that make it possible to estimate the efficiency and cost of future beamlines using a chemical oxygen-iodine laser as a neutralizer. These studies indicate that a 400-keV neutral deuterium beam of more than 20 A will operate at an efficiency >60%, with the capital cost of the neutralizer at less than $2/W of neutral beam output. Beamlines of lower current and less energy will operate at poorer efficiencies and higher neutralizer costs per watt of neutral beam. These are estimates. As they are very sensitive to changes in the assumptions from which they were derived, they must be used with some caution. Additional studies are expected to provide more reliable estimates.

1984-11-01

114

Observation of a surface peak in low energy implant depth profiles in silicon  

Energy Technology Data Exchange (ETDEWEB)

In situ Auger sputter depth profiles of saturation implants of 3 keV N/sub 2//sup +/ in silicon at room temperature exhibit a sharp peak in the nitrogen concentration in the outermost layers, followed by a monotonic decrease. No broad plateau was observed. The energy of the Auger line corresponding to the Si(2p) core electron excitation, monitored throughout the profiling, exhibits a chemical shift of up to 7 eV at the surface peak concentration. Inert gas ion post-bombardment of unsaturated implants significantly modifies the profile, and supports the suggestion that the surface peak arises through radiation enhanced diffusion of implanted atoms.

1984-03-01

115

Aqueous radioactive waste bituminization  

International Nuclear Information System (INIS)

The bituminzation of decontamination and ion exchange resin stripping wastes with four grades of asphalt was investigated to determine the effects of asphalt type on the properties of the final products. All waste forms deformed readily under light loads indicating they would flow if not restrained. It was observed in all cases that product leaching rates increased as the hardness of the asphalt used to treat the waste increased. If bituminization is adopted for any Ontario Hydro aqueous radioactive wastes they should be treated with soft asphalt to obtain optimum leaching resistance and mechanical stability during interim storage should be provided by a corrosion resistant container.

5049-01-01

116

Investigation of acoustic waves generated in an elastic solid by a pulsed ion beam and their application in a FIB based scanning ion acoustic microscope  

International Nuclear Information System (INIS)

The aim of this work is to investigate the acoustic wave generation by pulsed and periodically modulated ion beams in different solid materials depending on the beam parameters and to demonstrate the possibility to apply an intensity modulated focused ion beam (FIB) for acoustic emission and for nondestructive investigation of the internal structure of materials on a microscopic scale. The combination of a FIB and an ultrasound microscope in one device can provide the opportunity of nondestructive investigation, production and modification of micro- and nanostructures simultaneously. This work consists of the two main experimental parts. In the first part the process of elastic wave generation during the irradiation of metallic samples by a pulsed beam of energetic ions was investigated in an energy range from 1.5 to 10 MeV and pulse durations of 0.5-5 #mu#s, applying ions with different masses, e.g. ...

117

The influence of target backing on ion-beam electron spectra  

International Nuclear Information System (INIS)

Several different aspects of the influence of the target backing on in-beam electron spectra following compound nuclear reactions induced by accelerated ions at tandem energies irradiating backed targets are discussed in detail. This discussion is illustrated by a few typical examples, such as "1"2C"5"+ and "3"1P"1"0"+ beams at 4 MeV/u bombarding Sn(+Be), Sn(+Au), Pb(+C) backed targets. Moreover, the relative influence of electron backscattering, electron Doppler shift and Doppler broadening as well as #delta#-electron emission on the low energy electron spectra (E_e#<=#100 keV) obtained under such conditions are investigated in the frame of the available experimental data. (orig.).

118

Suppression of transient enhanced diffusion following {ital in} {ital situ} photoexcitation during boron ion implantation  

Energy Technology Data Exchange (ETDEWEB)

The effect of {ital in} {ital situ} photoexcitation during boron ion implantation on subsequent transient enhanced B diffusion in Si has been investigated. Photoexcitation using a mercury arc lamp was performed during B{sup +} implantation at 35 keV for a dose of 5{times}10{sup 14} cm{sup {minus}2} at 177 K. A reduction in the electrical activation dip, i.e., reverse annealing effect, in the temperature range 550--700 {degree}C was observed. Also, the transient enhanced diffusion of B, measured using SIMS following 800 {degree}C, 30 min annealing, was suppressed. Both effects demonstrate that the creation of self-interstitials during the implantation process is significantly reduced. {copyright} {ital 1995} {ital American} {ital Institute} {ital of} {ital Physics}.

1995-10-09

119

Suppression of transient enhanced diffusion following in situ photoexcitation during boron ion implantation  

International Nuclear Information System (INIS)

The effect of in situ photoexcitation during boron ion implantation on subsequent transient enhanced B diffusion in Si has been investigated. Photoexcitation using a mercury arc lamp was performed during B"+ implantation at 35 keV for a dose of 5x10"1"4 cm"-"2 at 177 K. A reduction in the electrical activation dip, i.e., reverse annealing effect, in the temperature range 550--700 degree C was observed. Also, the transient enhanced diffusion of B, measured using SIMS following 800 degree C, 30 min annealing, was suppressed. Both effects demonstrate that the creation of self-interstitials during the implantation process is significantly reduced. copyright 1995 American Institute of Physics.

120

Resonant neutralization of He ions into excited states at Cu(110) and Ni(110) surfaces  

Energy Technology Data Exchange (ETDEWEB)

He ions incident at grazing angles on Cu(110) and Ni(110) surfaces are neutralised into triplet and singlet states, of which the 3p, 3d and 4d upper states are accessible to optical spectroscopy. In the energy range from 500 eV to 15 keV no significant energy dependence of the relative intensities of singlet and triplet lines was observed for scattering on Cu(110). The intensities from Ni(110) are higher and the singlet to triplet intensity ratio of the 3d to 2p transition is about 6% smaller than that from Cu(110). The results can be explained well by assuming resonant charge capture into excited He and intermediate formation of negative He/sup -/ states.

1984-03-01

121

Resonant neutralization of He ions into excited states at Cu(110) and Ni(110) surfaces  

International Nuclear Information System (INIS)

He ions incident at grazing angles on Cu(110) and Ni(110) surfaces are neutralised into triplet and singlet states, of which the 3p, 3d and 4d upper states are accessible to optical spectroscopy. In the energy range from 500 eV to 15 keV no significant energy dependence of the relative intensities of singlet and triplet lines was observed for scattering on Cu(110). The intensities from Ni(110) are higher and the singlet to triplet intensity ratio of the 3d to 2p transition is about 6% smaller than that from Cu(110). The results can be explained well by assuming resonant charge capture into excited He and intermediate formation of negative He"- states. (orig.).

1983-07-01

122

Recent advance of focused ion beam technology in maskless deposition and patterning  

International Nuclear Information System (INIS)

The present article will review recent advances in focused ion beam (FIB) technology. With increasing demands for scale of integration, microfabrication technology is becoming more important and various new microfabrication tools and processing techniques are desired. FIB is one of the promising tools for future microfabrication technology. This provides maskless patterning capability, which is of importance for process simplification, nanofabrication and in the development of in situ vacuum processing. In situ vacuum processing systems are being developed by combining FIB and a molecular beam epitaxy system. Radiation damage may limit applications of FIB. However, it was demonstrated that low energy FIB (<1 keV) with very high brightness was reached and promising results for low damage processing have been obtained. (orig.).

123

Infrared monitoring of the Doublet III beam armor plate  

Energy Technology Data Exchange (ETDEWEB)

An 80 keV, 3.6 MW neutral beam injection system has recently been installed on Doublet III, and the installation of a second system is scheduled within several months. Armor plate consisting of /approximately equals/100 graphite tiles (10 cm x 10 cm) coated with TiC has been plated over portions of the inner vacuum wall lying in the line of sight of the ion sources. In order to monitor the condition of the armor plate an infrared camera and a set of optical pyrometers have been installed alongside the beamline and view the armor plate through a CaF/sub 2/ window. The pyrometers measure the temperature of the armor plate associated with the maximum of the intensity distribution of each ion source.

1981-01-01

124

Boron transient enhanced diffusion in heavily phosphorus doped silicon  

International Nuclear Information System (INIS)

A study has been made of B transient enhanced diffusion (TED) in heavily P-doped Si using secondary ion mass spectroscopy (SIMS) and positron annihilation spectroscopy (PAS). The P-doped silicon was implanted with boron ions of 40 keV energy to a dose of 3 x 10"1"4 cm"-"2, and then annealed at temperatures ranging from 700--1,000 C in a N_2 ambient for varying durations. As P doping concentration increased from 3 x 10"1"9 to 1 x 10"2"0 cm"-"3, boron diffusivity and the immobile boron fraction decreased. The experimental results are inconsistent with the predictions of the Fermi-level model and suggest that the clustering between B atoms and Si interstitials should be invoked in order to explain the immobile portion of the B peak during TED.

1996-12-02

125

Atomic scale simulations of arsenic ion implantation and annealing in silicon  

International Nuclear Information System (INIS)

We present results of multiple-time-scale simulations of 5, 10 and 15 keV low temperature ion implantation of arsenic on silicon (100), followed by high temperature anneals. The simulations start with a molecular dynamics (MD) calculation of the primary state of damage after 10ps. The results are then coupled to a kinetic Monte Carlo (MC) simulation of bulk defect diffusion and clustering. Dose accumulation is achieved considering that at low temperatures the damage produced in the lattice is stable. After the desired dose is accumulated, the system is annealed at 800 degrees C for several seconds. The results provide information on the evolution for the damage microstructure over macroscopic length and time scales and affords direct comparison to experimental results. We discuss the database of inputs to the MC model and how it affects the diffusion process.

2004-12-15

126

Determination of Proper Peaking Time for Ultra Lege detector at Medium Energies  

International Nuclear Information System (INIS)

Reducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the optimum peaking time for particular detector systems is important. For this purpose, pure Se and Zn elements were excited by 59.5 keV ?-rays from a 50 mCi 241Am annular radioactive source in this study. The characteristic x-rays emitted from pure Se and Zn elements were detected by using an ultra low energy Ge (Ultra-LEGe) detector connecting Tennelec TC 244 spectroscopy amplifier at different peaking time modes. Overall pulse widths were determined by HM 203-7 oscilloscope connecting amplifier. The proper peaking time for ultra low energy germanium detector (Ultra-LEGe) is determined about 4 ?s.

2008-08-25

127

Synthesis, structural characterization, and performance evaluation of resorcinol-formaldehyde (R-F) ion-exchange resin  

International Nuclear Information System (INIS)

The 177 underground storage tanks at the DOE's Hanford Site contain an estimated 180 million tons of high-level radioactive wastes. It is desirable to remove and concentrate the highly radioactive fraction of the tank wastes for vitrification. Resorcinol-formaldehyde (R-F) resin, an organic ion-exchange resin with high selectivity and capacity for the cesium ion, which is a candidate ion-exchange material for use in remediation of tank wastes. The report includes information on the structure/function analysis of R-F resin and the synthetic factors that affect performance of the resin. CS-100, a commercially available phenol-formaldehyde (P-F) resin, and currently the baseline ion-exchanger for removal of cesium ion at Hanford, is compared with the R-F resin. The primary structural unit of the R-F resin was determined to consist of a ...

2004-09-10

128

Shutdown Chemistry Process Development for PWR Primary System  

Energy Technology Data Exchange (ETDEWEB)

This study report presents the shutdown chemistry of PWR primary system to reduce and remove the radioactive corrosion products which were deposited on the nuclear fuel rods surface and the outside of core like steam generator channel head, RCS pipings etc. The major research results are the follows ; the deposition radioactive mechanism of corrosion products, the radiochemical composition, the condition of coolant chemistry to promote the dissolution of radioactive cobalt and nickel ferrite, the control method of dissolved hydrogen concentration in the coolant by the mechanical and chemical methods. The another part of study is to investigate the removal characteristics of corrosion product ions and particles by the demineralization system to suggest the method which the system could be operate effectively in shut-down purification period. (author). 19 refs., 25 figs., 48 tabs.

1997-12-31

129

Process for preparing inorganic particulate adsorbent and process for treating nuclear reactor core-circulating water  

Energy Technology Data Exchange (ETDEWEB)

An inorganic particulate adsorbent of a titania-alumina is described for treating a superheated water containing radioactive materials such as cobalt ions, which is free from release of corrosive impruities, and which has a high adsorption capacity of radioactive materials and a high mechanical strength is prepared by hydrolyzing a titanium alkoxide and an aluminum alkoxide, thereby forming a hydrous titanium oxide and a hydrous aluminum oxide, respectively; precalcining the hydrous titanium oxide and aluminum oxide, mixing and molding the resulting titania and alumina into a particulate mixture thereof having a titania mole fraction of 0.2 to 0.9, and calcining the particulate mixture at 500/sup 0/-700/sup 0/C. This absorbent is effectively used in treat boiling water-type nuclear reactor core-circulating water to remove radioactive substances therefrom.

1981-08-04

130

Time-of-flight secondary ion mass spectrometry of fatty acids in rat retina  

Energy Technology Data Exchange (ETDEWEB)

The retina consists of many kinds of central nervous cells, and some cells contain fatty acids such as palmitic acid, stearic acid and oleic acid. Time-of-flight secondary ion mass spectrometry (TOF-SIMS) has a possibility to detect kinds and quantity of materials in relation to the cell or tissue. We applied TOF-SIMS to detect the palmitic acid, stearic acid and oleic acid in the visual cell of the rat retina. We used 4- and 18-month-old normal Wistar Kyoto rats. After pentobarbital anesthesia, the eyes were enucleated, and immediately put into liquid nitrogen without any fixation and then cut into semithin sections (10 {mu}m) with a cryo-ultramicrotome, and laid it on a silicon wafer plate and air-dried. Ion images were detected with TOF-SIMS. Positive ion images were examined with a Ga{sup +} source at an acceleration voltage of 15 keV. The secondary ion acceleration voltage was ...

2003-01-15

131

Research on Actinides in Nuclear Fuel Cycles  

International Nuclear Information System (INIS)

The electrochemical/spectroscopic integrated measurement system was designed and set up for spectro-electrochemical measurements of lanthanide and actinide ions in high temperature molten salt media. A compact electrochemical cell and electrode system was also developed for the minimization of reactants, and consequently minimization of radioactive waste generation. By applying these equipment, oxidation and reduction behavior of lanthanide and actinide ions in molten salt media have been made. Also, thermodynamic parameter values are determined by interpreting the results obtained from electrochemical measurements. Several lanthanide ions exhibited fluorescence properties in molten salt. Also, UV-VIS measurement provided the detailed information regarding the oxidation states of lanthanide and actinide ions in high temperature molten salt media

2007-04-01

132

Nuclear astrophysics with radioactive ion beams  

International Nuclear Information System (INIS)

Nuclear astrophysics seeks for a possible explanation of the observed abundance distribution of various elements and their isotopes in the universe. Most of the relevant nuclear reactions take place in thermally equilibrium environments with bare nuclei, rather than accelerated and head-on colliding situations with low ionisation states of reactant atoms and molecules that are emulated in the laboratories. Moreover, the temperature of the astrophysical environments is quite often low compared to the centre-of-mass energy of the projectile nuclides, that is required for the reaction to be meaningfully investigated in the laboratory. Therefore, an extrapolation of the data on the reaction cross sections to very low energies and to extremely high density situations is generally called for, which are substantially altered every now and then for a number of astrophysically important reactions. The radioactive ion beams will provide us important data ...

133

Collisional cooling of negative-ion beams  

Energy Technology Data Exchange (ETDEWEB)

Studies have been conducted to determine the feasibility of using collisional cooling for reducing emittances and energy spreads in negative-ion beams to levels commensurate with effective isobaric purification with conventional high-resolution electromagnetic isobar separators as required for use at the Holifield Radioactive Ion Beam Facility (HRIBF). We have designed a gas-filled radio frequency quadrupole ion cooler equipped with provisions for retarding energetic negative-ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to initial energies after the cooling process. The device has been used to cool several ion beams with initial energy spreads, {delta}E>10 eV to final energy spreads, {delta}E{approx}2 eV FWHM, including O{sup -} and F{sup -}. Overall transmission efficiencies of {approx}14% for F{sup ...

2002-01-01

134

Submicron-scale patterns on ferromagnetic-antiferromagnetic Fe/NiO layers by focused ion beam (FIB) milling  

Energy Technology Data Exchange (ETDEWEB)

With the aim of studying the magnetic properties of reduced-dimensionality magnetic systems we have patterned 250 nm- and 500 nm-size square elements on Fe/NiO layers by 30 keV Ga{sup +} focused ion beam (FIB) milling, varying beam current and pixel dwell time. By high resolution scanning electron microscope (SEM) imaging and atomic force microscopy (AFM) analysis we found that island size decreases from the nominal value by increasing the beam current and features sharpness improves on increasing the dwell time. The top surface of the isolated features has a pronounced edge bending which may be as high as 9 nm with respect to the flat inner area of the island and decreases as dwell time grows. By varying the ion fluence we found that such a shape is related to a surface swelling effect occurring at low ion fluence in the irradiated areas. The swelling-related damage at the edges is expected to ...

2005-04-01

135

Submicron-scale patterns on ferromagnetic-antiferromagnetic Fe/NiO layers by focused ion beam (FIB) milling  

International Nuclear Information System (INIS)

With the aim of studying the magnetic properties of reduced-dimensionality magnetic systems we have patterned 250 nm- and 500 nm-size square elements on Fe/NiO layers by 30 keV Ga"+ focused ion beam (FIB) milling, varying beam current and pixel dwell time. By high resolution scanning electron microscope (SEM) imaging and atomic force microscopy (AFM) analysis we found that island size decreases from the nominal value by increasing the beam current and features sharpness improves on increasing the dwell time. The top surface of the isolated features has a pronounced edge bending which may be as high as 9 nm with respect to the flat inner area of the island and decreases as dwell time grows. By varying the ion fluence we found that such a shape is related to a surface swelling effect occurring at low ion fluence in the irradiated areas. The swelling-related damage at the edges is expected to influence the ...

2005-04-01

136

Low-energy measurements of electron capture by multicharged ions from excited hydrogen atoms  

International Nuclear Information System (INIS)

For very low collision energies electron capture from excited hydrogen by multicharged ions is characterized by enormous cross sections, the predicted maximum being comparable to the geometric size of the Rydberg atom. The ion-atom merged-beams technique is being used to study these collisions for the variety of charge states and the wide range of energies (0.1 to 1000 eV/amu) accessible to the apparatus. A neutral D beam containing a Rydberg atom population proportional to 1/n"3 is produced by collisional electron detachment of 8 keV D"- in N_2 gas. An applied electric field results in the range (n=24--11) depending on the strength of the field applied. This beam is then merged with O"3"+ or O"5"+ ion beams at low relative collision velocities where the resultant beam-beam signal of D"+ due to electron loss is dominated by electron capture. From the sharp decrease in the observed beam-beam signal as ...

137

Doping of silicon carbide by ion implantation  

Energy Technology Data Exchange (ETDEWEB)

A brief survey is given of some recent results on doping of 4H- and 6H-SiC by ion implantation. The doses and energies used are between 10{sup 9} and 10{sup 15} cm{sup -2} and 100 keV and 5 MeV, respectively, and B and Al ions (p-type dopants) are predominantly studied. After low dose implantation ({<=}10{sup 10} cm{sup -2}) a strong compensation is observed in n-type samples and this holds irrespective of implantation temperature up to 600 C. However, at higher doses (10{sup 14}-10{sup 15} Al/cm{sup 2}) the rate of defect recombination (annihilation) increases substantially during hot implants ({>=}200 C), and in these samples one type of structural defect dominates after post-implant annealing at 1700-2000 C. The defect is identified as a dislocation loop composed of clustered interstitial atoms inserted on the basal plane in the hexagonal crystal structure. Finally, transient enhanced diffusion (TED) of ...

2001-07-01

138

Investigation of natural radionuclides in selected NORM-samples  

International Nuclear Information System (INIS)

A programme has been initiated by the Coordinating Office for Monitoring of enhanced natural radioactivity of the Federal Office for Radiation Protection to investigate different kinds of sample materials with enhanced naturally occurring radioactivity (NORM) such as scales from oilfield and naturally gasfield pipes, blast furnace sludge and sinter dust from the production of pig iron, as well as bauxit and red mud from the production of aluminium oxide. The aim of these investigations is to find proper preparation and measuring methods which allow, in particular, a sample treatment with optimised effort combined with a reliable determination of the specific activities of the dominating radionuclides. Of particular interest is the method of gamma-ray spectrometry, since this method has been used for most of our studies of sample materials. Due to different compositions of calibration and NORM-samples, e.g. different densities, and the analysis ...

2005-09-20

139

The Principles of Radioactive Waste Management  

CERN Document Server

The Principles of Radioactive Waste Management

1995-01-01

140

Establishing a nationalsystem for radioactive waste management  

CERN Document Server

Establishing a nationalsystem for radioactive waste management

1995-01-01

141

SIMS analysis of silicon on insulator structures formed by high-dose O/sup +/ implantation into silicon  

Energy Technology Data Exchange (ETDEWEB)

Silicon on insulator (SOI) structures are promising candidates for the fabrication of VLSI circuits with very high packing densities. The preparation of such structures can now be achieved by high dose implantation of reactive ion species such as oxygen to produce buried layers of SiO/sub 2/ in silicon. In this paper we report experiments to depth profile these layered structures by SIMS. SOI samples have been prepared by implanting (100) silicon wafers with 400 keV molecular oxygen ions at a dose of 1.8x10/sup 18/ O/sup +/ cm/sup -2/. During the implantation the wafers were maintained at temperatures between 325 and 600/sup 0/C, using beam heating, which achieved in situ-annealing and ensured that the top silicon layer remained single crystal. Analysis was carried out on an Atomika DIDA-II spectrometer using 10 keV Ar/sup +/ ions with a low current density of less than 1 mA cm/sup ...

1983-12-15

142

Impurity and clustering effects on defect evolution in ion-implanted Si  

Energy Technology Data Exchange (ETDEWEB)

A detailed investigation of the damage formation and evolution in ion-implanted crystalline Si is presented. Deep-level transient spectroscopy has been used to monitor room temperature migration of point defect complexes and evolution from simple point-like defect complexes to defect clusters and even extended defects. Si samples were implanted with Si or He ions with energies of 145 keV-3MeV, to fluences in the range 5x10[sup 8]-5x10[sup 13]cm[sup -2]. The effects of thermal annealing, in the range 100-680 C and 10 min-15h, were also explored. A systematic comparison of defect complexes formation and evolution in ion-implanted or electron-irradiated Si samples with a different impurity content were used to assess the role of impurities (C and O), extra implanted ion and defect clustering on the nature and thermal stability of residual damage. In particular, an interstitial excess ...

1998-10-01

143

Extension of improved particle and energy confinement regime in the core of LHD plasma  

International Nuclear Information System (INIS)

Recent two major topics of Large Helical Device (LHD) towards fusion relevant conditions, high-density operation and high-ion-temperature operation, are reported. Super dense core plasma was obtained by the combination of repetitive hydrogen ice pellet injection and high power neutral beam injection (NBI) heating. A very peaked density profile with the highest central density of 1.1x1021 m-3 was produced showing that the particle transport was suppressed very well in the plasma core. The spatial density varies as the position of magnetic axis (Rax), and the steepest profile is obtained at Rax=3.95 m. The highest central ion temperature of 5.6 keV was obtained in hydrogen plasma at electron density of 1.6 x 1019 m-3 by NBI, where a peaked ion-temperature profile with internal ion energy transport barrier was observed. The profile of electron temperature did not change much and was ...

2009-06-01

144

Measurement of relative L X-ray intensity ratio following radioactive decay and photoionization  

Energy Technology Data Exchange (ETDEWEB)

The measurements of the L X-ray intensity ratio I(L{alpha})/I(L{beta}), I(L{alpha})/I(L{gamma}), I(L{alpha})/I(L{iota}), I(L{beta})/I(L{gamma}) and I(L{iota})/I(L{gamma}) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a filtered radioisotope {sup 241}Am was used, and by the radioactive decay of {sup 160}Tb, {sup 160}Er, {sup 173}Lu, {sup 182}Re, {sup 201}Tl, {sup 203}Pb and {sup 207}Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L{alpha}/L{beta}), I(L{alpha}/L{gamma}), I(L{alpha}/L{iota}), I(L{beta}/L{gamma}) and I(L{iota}/L{gamma}) intensity ratios were calculated using theoretically tabulated values of subshell photoionization cross-section, fluorescence yield, fractional X-ray ...

2008-05-22

145

Transient enhanced diffusion of Sb and B due to MeV silicon implants  

Energy Technology Data Exchange (ETDEWEB)

We measure the transient enhanced diffusion of shallow molecular-beam-epitaxy grown marker layers of Sb and B due to deep MeV Si{sup +} ion implants at very high doses ({approx}10{sup 16}cm{sup {minus}2}). We expect the near-surface region of these implants to be vacancy rich, and we observe transient enhanced diffusion of Sb (the classic vacancy diffuser). The large enhancements imply a significant vacancy supersaturation ({approx}700 at 740{degree}C). Double implantation of the high-dose MeV Si followed by a shallow (40 keV) Si implant and annealing produces a greatly reduced number of {l_brace}311{r_brace} defects compared to a 40 keV implant into virgin Si, again consistent with a vacancy-rich region in the near-surface region of an MeV implant. However, the shallow B marker layers also show transient enhanced diffusion for the same MeV implant under similar annealing conditions, implying that an interstitial ...

1997-06-01

146

Transient enhanced diffusion of Sb and B due to MeV silicon implants  

International Nuclear Information System (INIS)

We measure the transient enhanced diffusion of shallow molecular-beam-epitaxy grown marker layers of Sb and B due to deep MeV Si"+ ion implants at very high doses (#approx#10"1"6cm"-"2). We expect the near-surface region of these implants to be vacancy rich, and we observe transient enhanced diffusion of Sb (the classic vacancy diffuser). The large enhancements imply a significant vacancy supersaturation (#approx#700 at 740 degree C). Double implantation of the high-dose MeV Si followed by a shallow (40 keV) Si implant and annealing produces a greatly reduced number of #left brace#311#right brace# defects compared to a 40 keV implant into virgin Si, again consistent with a vacancy-rich region in the near-surface region of an MeV implant. However, the shallow B marker layers also show transient enhanced diffusion for the same MeV implant under similar annealing conditions, implying that an interstitial supersaturation is ...

147

Microstructures for high-energy x-ray and particle-imaging applications  

Energy Technology Data Exchange (ETDEWEB)

Coded imaging techniques using thick, micro-Fresnel zone plates as coded apertures have been used to image x-ray emissions (2-20 keV) and 3.5 MeV Alpha particle emissions from laser driven micro-implosions. Image resolution in these experiments was 3-8 ..mu..m. Extension of this coded imaging capability to higher energy x-rays (approx. 100 keV) and more penetrating charged particles (e.g. approx. 15 MeV protons) requires the fabrication of very thick (50-200 ..mu..m), high aspect ratio (10:1), gold Fresnel zone plates with narrow linewidths (5-25 ..mu..m) for use as coded aperatures. A reactive ion etch technique in oxygen has been used to produce thick zone plate patterns in polymer films. The polymer patterns serve as electroplating molds for the subsequent fabrication of the free-standing gold zone plate structures.

1981-05-01

148

Microstructures for high-energy x-ray and particle imaging applications  

Energy Technology Data Exchange (ETDEWEB)

Coded imaging techniques using thick, micro-Fresnel zone plates as coded apertures have been used to image x-ray emission (2--20 keV) and 3.5 MeV Alpha particle emissions from laser driven micro-implosions. Image resolution in these experiments was 3--8 ..mu..m. Extension of this coded imaging capability to higher energy x rays (approx.100 KeV) and more penetrating charged particles (e.g., approx.15 MeV protons) requires the fabrication of very thick (50--200 ..mu..m), high aspect ratio (10:1), gold Fresnel zone plates with narrow linewidths (5--25 ..mu..m) for use as coded apertures. A reactive ion etch technique in oxygen has been used to produce thick zone plate patterns in polymer films. The polymer patterns serve as electroplating molds for the subsequent fabrication of the free-standing gold zone plate structures.

1981-11-01

149

Purification of radioactive decontamination liquids from NPP Paks with reactive adsorption and ion-exchange process  

International Nuclear Information System (INIS)

In nuclear power plant Paks, Hungary, alkaline oxidative (NaOH, KMnO_4, H_2O) and acidic reductive (citric- and oxalic acid, water) liquids are using for the decontamination of primary circuit equipment (main liquid circulating pumps, steam generators, pipelines etc). The above mentioned decontamination liquids are containing "1"1"0"mAg, "9"5Nb, "5"4Mn, "5"8 Co, "6"0Co, "5"1 Cr, "1"2"4 Sb radioisotopes, summarized radioactivity is between 10"3-8x10"4 kBq/dm"3 liquid. The decontamination liquid can be cleaned with reactive adsorption (active carbon) and ion-exchange process at elevated temperature (333-368 K) in multilayered columns. After purification the summarized radioactivity for "5"4Mn, "6"0Co, and "1"1"0"mAg are in the outlet liquid below 1 kBq/dm"3. Decontamination factor DF#approx =#10"3-10"4, volumetric reduction factor VRF#approx =#50-500.

1999-11-04

150

Coir pith of the green coconut in the decontamination of radioactive aqueous effluent  

International Nuclear Information System (INIS)

Industrial segments as plant of mining, hospitals and university generate considerable volumes of radioactive wastewater containing uranium. The increasing development of the use of the nuclear energy to lead away to an expansion of the sectors of the nuclear fuel cycle, but it leads to security problems and it appears the necessity of control of the removing of uranium and radioactive effluent treatments. Researches evaluate if the technique of the biosorption would promote an alternative process with attractive characteristics of cost-benefit. The residual biomass from agricultural activities has been studied and used as adsorbent of metals and organic composts by low cost, abundance and for being biodegradable. In this work, it is presented the efficiency of the coir pith for the adsorption of ions UO_2"2"+. The coir pith is a by-product of the harvest of the coconut, a renewable natural source. The study was ...

151

Production of atomic negative ion beams of the Group IA elements  

Energy Technology Data Exchange (ETDEWEB)

A method has been developed which enables the direct sputter generation of atomic negative ion beams of all members of the Group IA elements (Li, Na, K, Rb, and Cs). The method consists of the use of sputter samples formed by pressing mixtures of the carbonates of the Group IA elements and 10% (atomic) Cu, Ag, or other metal powder. The following intensities are typical of those observed from carbonate samples subjected to /approximately/3 KeV cesium ion bombardment: Li/sup -/: greater than or equal to0.5 ..mu..A; Na/sup -/: greater than or equal to0.5 ..mu..A; K/sup -/: greater than or equal to0.5 ..mu..A; Rb/sup -/: greater than or equal to0.5 ..mu..A; Cs/sup -/: greater than or equal to0.2 ..mu..A. 7 refs., 2 figs., 1 tab.

1988-01-01

152

Low temperature formation of shallow p{sup +}n junctions by BF{sub 2}{sup +} implantation into thin Pd{sub 2}Si films on Si substrates  

Energy Technology Data Exchange (ETDEWEB)

Excellent silicided shallow p{sup +}n junctions have been successfully achieved by the implantation of BF{sub 2}{sup +} ions into thin Pd{sub 2}Si films on Si substrates to a dose of 5 {times} 10{sup 15} cm{sup {minus}2} and subsequent low temperature (even at 550 C) furnace annealing. The formed junctions have been characterized for respective implantation conditions. In this experiment, the implant energy is the key role in obtaining a low leakage diode. Reverse current density of about 3 nA/cm{sup 2} and an ideality factor of about 1.05 can be attained by the implantation of BF{sub 2}{sup +} ions at 80 keV and subsequent annealing at 550 C. The junction depth is about 0.09 {mu}m, measured by the spread resistance method. As compared with the results of unimplanted specimens, the implantation of BF{sub 2}{sup +} ions into a thin Pd{sub 2}Si layer can stabilize the silicide film and prevent it from ...

1995-05-01

153

Enhancement of electrical conductivity of ion-implanted polymer films  

Energy Technology Data Exchange (ETDEWEB)

The electrical conductivity of ion-implanted films of Nylon 66, Polypropylene (PP), Poly(tetrafluoroethylene) (Teflon) and mainly Poly (ethylene terephthalate) (PET) was determined by DC measurements at voltages up to 4500 V and compared with the corresponding values of pristine films. Measurements were made at 21/sup 0/C +/- 1/sup 0/C and 65 +/- 2% RH. The electrical conductivity of PET films implanted with F/sup +/, Ar/sup +/, or As/sup +/ ions at energies of 50 keV increases by seven orders of magnitude as the fluence increases from 1 x 10/sup 18/ to 1 x 10/sup 20/ ions/m/sup 2/. The conductivity of films implanted with As/sup +/ was approximately one order greater than those implanted with Ar/sup +/, which in turn was approximately one-half order greater than those implanted with F/sup +/. The conductivity of the most conductive film approx.1 S/m) was almost 14 orders of magnitude greater than the ...

1985-01-01

154

Effect of helium and hydrogen production on irradiation hardening of F82H steel irradiated by ion beams  

International Nuclear Information System (INIS)

Effects of helium and hydrogen production on irradiation hardening of martensitic steel F82H (Fe-8Cr-2W-0.2V-0.04Ta-0.1C) were examined by dual or triple beam experiments. The effects of tempering and cold working were also examined. The irradiations were performed at about 500degC to 50 dpa under simultaneous dual beams of 10.5 MeV Fe"3"+ and 1.05 MeV He"+ or triple beams of those and 380 keV H"+ ions. The value of appm-He/dpa for the dual ion beams was about 15, and the values of appm-He/dpa and appm-H/dpa for the triple ion beams were 15 and 15 (or 150), respectively. The hardness of the irradiated specimens measured at room temperature using a micro indentation after the irradiations. Irradiation softening and hardening was observed in F82H-std, F82H+20%CW and a non-tempered F82H steels irradiated at about 500degC to 18 and 50 dpa, respectively, by dual ion beams. The hardness ...

2007-06-01

155

Triple ion-beam studies of radiation damage in 9Cr2WVTa ferritic/martensitic steel  

Energy Technology Data Exchange (ETDEWEB)

To simulate radiation damage under a future Spallation Neutron Source (SNS) environment, irradiation experiments were conducted on a candidate 9Cr-2WVTa ferritic/martensitic steel using the Triple Ion Facility (TIF) at ORNL. Irradiation was conducted in single, dual, and triple ion beam modes using 3.5 MeV Fe{sup ++}, 360 keV He{sup +}, and 180 keV H{sup +} at 80, 200, and 350{degrees}C. These irradiations produced various defects comprising black dots, dislocation loops, line dislocations, and gas bubbles, which led to hardening. The largest increase in hardness, over 63 %, was observed after 50 dpa for triple beam irradiation conditions, revealing that both He and H are augmenting the hardening. Hardness increased less than 30 % after 30 dpa at 200{degrees}C by triple beams, compatible with neutron irradiation data from previous work which showed about a 30 % increase in yield strength after 27.2 dpa ...

1997-11-01

156

Defect engineering via ion implantation to control B diffusion in Si  

International Nuclear Information System (INIS)

The processes which are currently studied in the fabrication of B-doped ultra shallow junctions (USJ) usually involve a preamorphization step to reduce B channelling effect during implantation and to improve B electrical activation. At this stage a high amount of Si interstitial atoms (Is), which dramatically increases the B diffusivity, is introduced. The introduction of voids in Si is a promising tool to control B transient enhanced diffusion (TED), because of their ability to capture Is. In this work the efficiency of a cavity band to reduce B TED is checked in silicon interstitial supersaturation conditions, obtained by high dose Si implantation. He is implanted either at 10 keV or at 50 keV with a fluence of 5 x 10"1"6 cm"-"2. Conventional techniques to introduce and activate the B (conventional ion implantation and rapid thermal annealing (RTA)) are applied in order to have a better control of the technological ...

2009-03-15

157

Time-of-flight measurements of light molecular ions scattered at grazing incidence from a Ni(111) surface  

Energy Technology Data Exchange (ETDEWEB)

A time-of-flight mass spectrometer has been constructed to measure the energy spectra of particles scattered by 10/sup 0/ with primary energies between 200 eV and 15 keV. The energy resolution ..delta..E/E of the system is between 0.1 and 0.4%. Energy spectra of scattered molecules and their dissociation products are shown for 570 eV H/sub 2//sup +/ and 4430 eV N/sub 2//sup +/ as projectiles. Electron capture into unbound states of the neutral molecule, with perhaps some contribution from mutual scattering within the molecule, appears to explain the observed dissociation product energy spectra peak widths.

1984-03-01

158

Time-of-flight measurements of light molecular ions scattered at grazing incidence from a Ni(111) surface  

International Nuclear Information System (INIS)

A time-of-flight mass spectrometer has been constructed to measure the energy spectra of particles scattered by 10"0 with primary energies between 200 eV and 15 keV. The energy resolution #DELTA#E/E of the system is between 0.1 and 0.4%. Energy spectra of scattered molecules and their dissociation products are shown for 570 eV H_2"+ and 4430 eV N_2"+ as projectiles. Electron capture into unbound states of the neutral molecule, with perhaps some contribution from mutual scattering within the molecule, appears to explain the observed dissociation product energy spectra peak widths. (orig.).

159

The fraction of substitutional boron in silicon during ion implantation and thermal annealing  

Energy Technology Data Exchange (ETDEWEB)

We present results from a kinetic Monte Carlo simulation of boron transient enhanced diffusion (TED) in silicon. Our approach avoids the use of phenomenological fits to experimental data by using a complete and self-consistent set of values for defect and dopant energetics derived mostly from {ital ab initio} calculations. The results predict that, during annealing of 40 keV B-implanted Si at 800{degree}C, there exists a time window during which all the implanted boron atoms are substitutional. At earlier or later times, the interactions between free silicon self-interstitials and boron atoms drive the growth of boron clusters and result in an inactive boron fraction. The results show that the majority of boron TED takes place during the growth period of interstitial clusters and not during their dissolution. {copyright} {ital 1998 American Institute of Physics.}

1998-05-01

160

The fraction of substitutional boron in silicon during ion implantation and thermal annealing  

International Nuclear Information System (INIS)

We present results from a kinetic Monte Carlo simulation of boron transient enhanced diffusion (TED) in silicon. Our approach avoids the use of phenomenological fits to experimental data by using a complete and self-consistent set of values for defect and dopant energetics derived mostly from ab initio calculations. The results predict that, during annealing of 40 keV B-implanted Si at 800 degree C, there exists a time window during which all the implanted boron atoms are substitutional. At earlier or later times, the interactions between free silicon self-interstitials and boron atoms drive the growth of boron clusters and result in an inactive boron fraction. The results show that the majority of boron TED takes place during the growth period of interstitial clusters and not during their dissolution. copyright 1998 American Institute of Physics.

1998-05-01

161

Partial wave expansion of ion-atom elastic scattering in solids  

International Nuclear Information System (INIS)

Elastic scattering cross sections of keV protons in solids (Z=3-82) are calculated using the partial wave expansion technique and the ''muffin-tin'' bound-atom potential. The differential cross sections for small scattering angles of less than 10deg are smaller than those with the Ziegler-Biersack-Littmark potential at all energies and for all solids, although, for larger angles, the two cross sections agree with each other. The mean free paths of the protons in the solids, obtained from the total cross sections, decrease very slowly with decreasing energy. Furthermore, at low energies they approach half the nearest-neighbor distance, which is taken as the radius of the augmented plane wave sphere in the muffin-tin model of crystalline solids. (orig.).

162

Milling materials using CO{sub 2} clusters; Materialbearbeitung durch Clusterionenbeschuss  

Energy Technology Data Exchange (ETDEWEB)

The Sputter coefficient of accelerated CO{sub 2} cluster ions hitting surfaces of various materials is investigated. For copper it varies proportional to the 2nd power of the energy between 155 and 260 keV. The rate of erosion for different target materials varies by two orders of magnitude from tungsten to PMMA. Diamond is eroded fairly quickly, while aluminum is eroded less than corundum (Al{sub 2}O{sub 3}). No simple correlation of the sputter coefficient on the bulk material properties is found. For copper the angular distribution of sputtered material is measured and found to be following roughly a cosine distribution. By using masks different microstructures have been produced in cobalt-samarium magnets, diamond and glass. (orig.)

1993-10-01

163

Influence of fluorine on the simulation of the transient enhanced diffusion of 15 keV BF_2"+ ion implantation into silicon  

International Nuclear Information System (INIS)

We have simulated the transient enhanced diffusion (TED) of boron fluoride (BF_2"+) implanted in crystalline and germanium amorphized silicon. Based on recently published models, the effect of fluorine on boron diffusion in silicon has been introduced and a modelling has been suggested. In order to simulate the boron experimental profiles, we have assumed that fluorine forms clusters involving interstitial boron which reduces the junction depth. Experimental results indicate that fluorine behaviour depends on amorphization energy. Moreover, even no germanium preamorphization is performed, silicon is still amorphized by fluorine species. Hence, BF_2"+ implantation leads to an amorphous/crystalline (a/c) interface near the surface. An improvement of published models is suggested taking into account fluorine effects. The simulations satisfactory reproduce the SIMS experimental profiles for a large scale of experimental conditions.

2002-01-01

164

Implant damage and redistribution of indium in indium-implanted thin silicon-on-insulator  

Energy Technology Data Exchange (ETDEWEB)

The indium implant damage and diffusion behavior in thin silicon-on-insulator (SOI) with a 200 nm top silicon layer were studied for different implantation energies and doses. Rutherford backscattering spectrometry in the channeling mode (RBS/C) was used to characterize the implant damage before and after annealing. Secondary ion mass spectrometry (SIMS) was used to study the indium transient enhanced diffusion (TED) behavior in the top Si layer of the SOI structure. An anomalous redistribution of indium after relatively high energy (200 keV) and dose (1 x 10{sup 14} cm{sup -2}) implantation was observed in both bulk Si and SOI substrates. However, there exist differences in these two substrates that are attributable to the more predominant out-diffusion of indium as well as the influence of the buried oxide layer in the SOI structure.

2004-12-15

165

Implant damage and redistribution of indium in indium-implanted thin silicon-on-insulator  

International Nuclear Information System (INIS)

The indium implant damage and diffusion behavior in thin silicon-on-insulator (SOI) with a 200 nm top silicon layer were studied for different implantation energies and doses. Rutherford backscattering spectrometry in the channeling mode (RBS/C) was used to characterize the implant damage before and after annealing. Secondary ion mass spectrometry (SIMS) was used to study the indium transient enhanced diffusion (TED) behavior in the top Si layer of the SOI structure. An anomalous redistribution of indium after relatively high energy (200 keV) and dose (1 x 10"1"4 cm"-"2) implantation was observed in both bulk Si and SOI substrates. However, there exist differences in these two substrates that are attributable to the more predominant out-diffusion of indium as well as the influence of the buried oxide layer in the SOI structure.

2004-12-15

166

Effect of pressure on the valence state of Yb in YbPd_2Si_2  

International Nuclear Information System (INIS)

The intermediate valent behaviour of YbPd_2Si_2 has been studied under pressure in the temperature range from 1.2 K to 90 K by using the 84 keV Moessbauer transition in "1"7"0Yb. At 54 kbar and 4.2 K we obtain an increase of the electric field gradient (EFG) by a factor of #approx =# 3. In addition, the EFG varies strongly with temperature, in contrast to the behaviour at ambient pressure. At 1.2 K a change of the hyperfine pattern is observed indicating a magnetic character of the Yb ion. These results provide evidence of a pressure induced change of the valence state close to 3+. (orig.).

167

Boron-enhanced-diffusion of boron: The limiting factor for ultra-shallow junctions  

Energy Technology Data Exchange (ETDEWEB)

Reducing implant energy is an effective way to eliminate transient enhanced diffusion (TED) due to excess interstitials from the implant. It is shown that TED from a fixed Si dose implanted at energies from 0.5 to 20 keV into boron doping-superlattices decreases linearly with decreasing Si ion range, virtually disappearing at sub-keV energies. However, for sub-keV B implants diffusion remains enhanced and x{sub j} is limited to {ge} 100 nm at 1,050 C. The authors term this enhancement, which arises in the presence of B atomic concentrations at the surface of {approx} 6%, Boron-Enhanced-Diffusion (BED).

1997-12-01

168

A principle of charged particle trapping by RF electromagnetic field in the spherical cavity  

Energy Technology Data Exchange (ETDEWEB)

A new principle of particle trapping in the simple spherical cavity using both electric and magnetic components of radiofrequency electromagnetic field is proposed. The electric component of H {sub 12} oscillating mode drives the fast particle oscillations, while the magnetic component synchronously bends the trajectories to the cavity center. A specially developed theory of particle stability predicts dense and energetic electron cluster in the trap. Numerical simulations of particle dynamics in the complete electromagnetic field taking into account both space charge and particle-induced magnetic field are in good agreement with the analytic results, giving a density of 2.6*10{sup 1} electrons/cm{sup 3} and an average kinetic energy of around 30 keV at an operating frequency of 3 GHz. Being used at lower frequency, spherical cavity can trap protons and heavier ions too, but with lower density and kinetic energy.

2005-11-21

169

An Experimental Apparatus Proposed for Efficient Removal of Isobaric Contaminants in Negative Ion Beams  

Energy Technology Data Exchange (ETDEWEB)

Isobaric contaminants are often problematical in accelerated negative ion beams for research at certain radioactive ion beam (RIB) and accelerator mass spectrometry (AMS) facilities since their presence in low-intensity rare isotopic beams seriously compromise experimental results. This article describes a non-resonant, laser-based photo-detachment apparatus for use at these facilities, which, according to calculations efficiently removes isobaric contaminants from these beams. The advantage of the system for isobaric contaminant removal over other systems proposed to date lies in its ability to efficiently capture easily transportable energetic negative ion beams with low, intermediate or high energy spreads by a superconducting solenoid magnetic field. The ability to change the diameter of captured beams by adjusting the magnetic field strength permits optimum control of the radial overlap of the ...

2008-09-01

170

Ultra shallow P+/N junctions using plasma immersion ion implantation and laser annealing for sub 0.1#mu#m CMOS devices  

International Nuclear Information System (INIS)

Classical beam line ion implantation is limited to low energies and cannot achieve P+/N junctions requested for <45nm ITRS node. RTA (rapid thermal annealing) needs to be improved for dopants activation and damage reductions. Spike annealing process also induces a large diffusion mainly due to TED (transient enhanced diffusion). Compared to conventional beam line ion implantation limited to a minimum energy implantation of 200eV, plasma immersion ion implantation (PIII) is an emerging technique to get ultimate shallow profiles (as-implanted) due to no lower limitation of energy and high dose rate. On the another hand, laser thermal processing (LTP) allows to obtain very shallow junction with no TED, abrupt profile and activated depth control. In this paper, we show the implementation of the BF_3 PIII associated with the LTP. Ions from BF_3"+ plasma have been implanted in 200mm n-type silicon wafers ...

2005-08-01

171

Transient enhanced diffusion from decaborane molecular ion implantation  

Energy Technology Data Exchange (ETDEWEB)

Transient enhanced diffusion (TED) from implantation of 5thinspkeVthinspB{sub 10}H{sub 14} and 0.5 keV B ions has been quantified and compared for nominal boron doses of 10{sup 14} and 10{sup 15}thinspcm{sup {minus}2}. Boron diffusivity during annealing was extracted from secondary ion mass spectroscopy depth profiles of diffused marker layers in boron doping-superlattices and the actual implanted B dose was independently measured by nuclear reaction analysis. Comparable enhancements were observed from both ions. Transmission electron microscopy analysis revealed that both boron- and decaborane-implanted samples were amorphized at a nominal 10{sup 15}thinspcm{sup {minus}2}thinspB dose. A comparison with data from low energy Si implants revealed a similar dependence of diffusivity enhancement on implant dose. These findings are consistent with the understanding that TED is caused by the interstitial ...

1998-10-01

172

Transient enhanced diffusion from decaborane molecular ion implantation  

International Nuclear Information System (INIS)

Transient enhanced diffusion (TED) from implantation of 5keVB_1_0H_1_4 and 0.5 keV B ions has been quantified and compared for nominal boron doses of 10"1"4 and 10"1"5cm"-"2. Boron diffusivity during annealing was extracted from secondary ion mass spectroscopy depth profiles of diffused marker layers in boron doping-superlattices and the actual implanted B dose was independently measured by nuclear reaction analysis. Comparable enhancements were observed from both ions. Transmission electron microscopy analysis revealed that both boron- and decaborane-implanted samples were amorphized at a nominal 10"1"5cm"-"2B dose. A comparison with data from low energy Si implants revealed a similar dependence of diffusivity enhancement on implant dose. These findings are consistent with the understanding that TED is caused by the interstitial supersaturation resulting from a number of excess interstitials ...

1998-10-01

173

Study of implantation damage in germanium formed using Ga"+ FIB  

International Nuclear Information System (INIS)

Full text: It is known that the ion implantation of germanium single crystals at room temperature results in drastic alteration of the germanium surface and the formation of cellular relief. Voids were found into the near-surface damage layer. The intersection of these voids with the germanium surface, as result of sputter etching, forms cellular relief. However, exact mechanism responsible for formation of the voids is not known. A 10 and 30 keV Ga"+ irradiation of Ge #left brace#100#right brace# crystal at room temperature was carried out using a focused ion beam (FIB) system with a dose in the range 0.5x10"1"2 to 1.5x10"1"4 ion/cm"2. The topology of the modified germanium surface and the structure of the radiation damage was studied using imaging facilities of the FIB systems and transmission electron microscopy. The strong cellular structure of Ge was observed after an ion dose ...

174

Properties of cubic boron nitride films with buffer layer control for stress relaxation using ion-beam-assisted deposition  

Energy Technology Data Exchange (ETDEWEB)

Significant ion irradiation during film growth is required for the formation of cubic boron nitride (cBN) films. Meanwhile, a huge level of intrinsic stress possibly induced by the ion bombardment has been frequently reported to result in cracking and/or lack of adhesion of deposited cBN films. The present work has been performed to investigate the interfacial and/or the buffer layer structures with better matching to the cBN film by relaxation of the film stress using ion-beam-assisted deposition (IBAD). Boron nitride films have been synthesized on Si(100) wafer and tungsten carbide (WC) substrates by depositing boron vapor under simultaneous bombardment with nitrogen ions and nitrogen-argon mixture ions in the energy range of 0.5-10 keV. Cubic BN films with enhanced tribological properties have been explored by inserting a BN layer with various B/N ...

1999-09-01

175

Optical image storage in ion implanted PLZT ceramics  

International Nuclear Information System (INIS)

We have demonstrated that optical images can be stored in transparent lead-lanthanum-zirconate-titanate (PLZT) ceramics by exposure to near-UV light with photon energies greater than the band gap energy of approx. equal to 3.35 eV. The image storage process relies on optically induced changes in the switching properties of ferroelectric domains (photoferroelectric effect). Stored images are nonvolatile but can be erased by uniform UV illumination and simultaneous application of an electric field. Although high quality images, with contrast variations of >= 100:1 and spatial resolution of approx. equal to 10 #mu#m, can be stored using the photoferroelectric effect, relatively high exposure energies (approx. equal to 100 mJ/cm"2) are required to store these images. This large exposure energy severely limits the range of possible applications of nonvolatile image storage in PLZT ceramics. We have recently found from studies of H, He and Ar implanted PLZT that the photosensitivity can ...

176

Characterization of a time-of-flight mass spectrometer and its applications in the study of solid surfaces; Charakterisierung eines Flugzeitmassenspektrometers und seine Anwendungen in der Festkoerperoberflaechenuntersuchung  

Energy Technology Data Exchange (ETDEWEB)

The object and the purpose of the present work was to develop, to assemble and to start running a new TOF (time of flight) mass spectrometer for imaging SNMS analytic which is optimized for the analysis of highly molecular secondary ions. The most important purpose was the characterization of the TOF mass spectrometer. The obtained mass spectra of indium, tantalum and silver clusters reflect the excellent properties of the TOF mass spectrometer for the detection of large clusters with good detection efficiency up to masses of 16000 amu. The possibility of the deflection of selected saturated atom and cluster peaks serves for further improvement of the detection efficiency for large molecules. The accessible mass resolution was determined to be of the order of m/{delta}m=1000 in the high mass region. Numerous measurements were carried out to characterize the useful yield of this spectrometer. For a best possible adaptation of the TOF mass spectrometer for the ...

2006-12-21

177

Uptake of cesium and strontium by crystalline silicotitanates from radioactive wastes  

British Library Electronic Table of Contents (United Kingdom)

Crystalline silicotitanate inorganic ion exchanger, with a sitinakite structure is candidate material for remediation of aqueous nuclear waste streams. The syntheses of crystalline silicotitanate (CST) and Nb-substituted crystalline silcotitanate (Nb-CST) were carried out under hydrothermal conditions and the products were characterized using techniques viz., XRD, SEM/EDS, DTA/TGA, surface area respectively. Batch experiments were carried out to study the kinetics of uptake of 137Cs and 90Sr, to estimate the decontamination factor (DF) values and distribution coefficients (K d) for the above synthesized CST and Nb-CST samples from actual radioactive waste solutions. The DF values for uptake of Cs and Sr by Nb-CST after 24?h of equilibration was 355 and 136 whereas for CST it was found to b...

2011-01-01

178

Analysis by high-performance liquid chromatography of radioactively labeled carbohydrate components of proteoglycans  

Energy Technology Data Exchange (ETDEWEB)

Methods were developed for the separation of radioactively labeled carbohydrate components of proteoglycans by isocratic ion-moderated partition HPLC. Neutral sugars were separated after hydrolysis in trifluoroacetic acid with baseline separation between glucose, xylose, galactose, fucose, and mannose. N-Acetylneuraminic acid, N-acetylated hexosamines, glucose, galactose, and xylitol were likewise well separated from each other under isocratic elution conditions. Glucuronic acid, iduronic acid, and their lactones were separated after hydrolysis in formic acid and sulfuric acid. Glucosamine, galactosamine, galactosaminitol, and glucosaminitol were separated by HPLC on a cation exchanger with neutral buffer after hydrolysis in hydrochloric acid. THe separation techniques also proved useful in fractionation of exoglycosidase digests of O- and N-linked oligosaccharides. Separations of aldoses, hexosamines, and uronic acids were adapted to sensitive ...

1986-04-01

179

Electron-beam-plasma ion source as source of negative fluorine  

Energy Technology Data Exchange (ETDEWEB)

Radioactive ion beams (RIBs) of short-lived isotopes of fluorine are in demand for investigating astrophysical phenomena related to the hot CNO cycle and rp processes responsible for stellar nucleosynthesis. Since negative ion beams are required for injection into tandem electrostatic accelerators, such as the 25 MV tandem accelerator used for post acceleration of RIBs for the Holifield Radioactive Ion Beam Facility (HRIBF) research program at the Oak Ridge National Laboratory (ORNL), efficient, direct-formation F{sup -} ion sources are highly desirable for RIB applications involving this type of post-accelerator. We have conceived and evaluated a direct extraction F{sup -} source for potential RIB applications which is predicated on the reverse polarity operation of a positive electron-beam-plasma target/ion source (EBPTIS) while ...

1997-11-01

180

Fluence- and exposure-to-dose conversion for human whole-body gamma irradiation  

International Nuclear Information System (INIS)

... kev range 10-100 kev range 100-1000 man mev range 01-10 personnel

1978-01-01

181

Three-step photoionization of mercury for application to separation of mercury isomers  

International Nuclear Information System (INIS)

Development of techniques for separating isomeric nuclides is important to the investigation of schemes for gamma-ray lasers. In preparation for an experiment to separate 10_1_4 atoms of the /sub 197m/Hg (299 keV, tau/sub 1/2/ = 24 hours) isomer, we report isotopically selective resonance ionization of mercury atoms. This has been accomplished by three-step excitation via the 6_3P"1 and 8_1S"0 excited states, using three collinear pulsed laser beams of 254, 286, and 532 nm wavelengths from a Nd:YAG and two dye lasers. These beams were passed through a closed mercury-vapor cell containing electrostatic plates to which the ions were drawn. Ion current and fluorescent radiation were measured as a function of laser frequency. Hyperfine structures for the 254- and 286-nm transitions were observed.

182

The peak to background method in quantitative ion microprobe analysis of thick biological specimens  

Energy Technology Data Exchange (ETDEWEB)

The use of the ratio of the characteristic intensity to the continuum background intensity (P/B ratio) of the X-ray spectrum for a quantitative ion microprobe (IMP) or PIXE (particle induced X-ray emission) analysis of thin biological specimens was proposed previously. The IMP analysis of thick biological specimens is also of considerable practical use. In this paper, the possibility of using the P/B ratio to quantify minor elements in thick biological specimens is investigated. The epoxy resin based standards with gradual concentrations of KCNS up to 0.6 mol/kg and NBS bovine liver were analyzed by a 27 MeV {alpha} particle microprobe. The measured peak to background ratios (between 4.4 to 5.7 keV) agreed well with the theoretical calculations. The calculations showed that the concentration dependence of the P/B ratios was determined mainly by the absorption of X-rays in specimens. The results indicate that the P/B method is useful for IMP ...

1991-05-01

183

Microstructural observation of focused ion beam modification of Ni silicides/Si thin films  

International Nuclear Information System (INIS)

Focused ion beam (FIB) irradiation of a thin Ni_2Si layer deposited on a Si substrate was carried out and studied using an in-situ transmission electron microscope (in-situ TEM). Square areas on sides of 4 by 4 and 9 by 9 microm were patterned at room temperature with a 25 keV Ga"+-FIB attached to the TEM. The structural changes of the films indicate a uniform milling, sputtering of the Ni_2Si layer and the damage introducing to the Si substrate. Annealing at 673 K results in the change of the Ni_2Si layer into an epitaxial NiSi_2 layer outside the FIB irradiated area, but several precipitates appear around the treated area. Precipitates was analyzed by energy dispersive X-ray spectroscopy (EDS). Larger amount of Ni than the surrounding matrix was found in precipitates. Selected area diffraction (SAD) patterns of the precipitates and the corresponding dark field images imply the formation of a Ni rich silicide. The relation between the FIB tail ...

1996-12-02

184

M X-ray production in Nd, Gd, Ho and Lu by 1-6 MeV lithium ions  

Energy Technology Data Exchange (ETDEWEB)

M-shell X-rays of the rare-earth elements {sub 60}Nd, {sub 64}Gd, {sub 67}Ho and {sub 71}Lu were measured for lithium ion bombardment in the energy range 1.0-6.0 MeV. The M-shell X-rays with energies of 0.978-1.631 keV were detected with a LINK analytical detector. The efficiency of the detector was determined by using the known atomic-field bremsstrahlung cross-sections from low energy electron beams and K-shell X-ray measurements with light projectiles. The measured cross-sections are compared to the predictions of the first Born approximation and the ECPSSR (energy loss and Coulomb deflection effects, perturbed stationary state approximation with relativistic correction) theories. The best theoretical description of the present data is given by the ECPSSR theory, even though the discrepancy between data and theory is increasing at higher projectile energies.

2004-06-01

185

Kinetic Monte Carlo (KMC) simulations for boron diffusion in ion-implanted crystalline materials  

Energy Technology Data Exchange (ETDEWEB)

In this paper, we report kinetic Monte Carlo study on the diffusion behavior of boron in silicon crystal, more particularly on the transient enhanced diffusion (TED) of boron in silicon during implantation and annealing. Firstly, the accuracy of our KMC code was verified by investigating the time evolutionary behavior of interstitial (I) and vacancy (V) when a silicon substrate is implanted with silicon dose with an energy of 10 keV and with a dose of 1 X 10{sup 14} ions/cm{sup 2}. To investigate the influence of native defects (I, V) on boron diffusion, a single and multi boron markers grown by MBE were employed. The simulation results revealed that the precursor of boron cluster (BI{sub 2}) is dominant at the initial stage of annealing, which explains the boron TED phenomenon in terms of the concentration of boron complexes and I, V clusters, respectively. The formation of {l_brace}311{r_brace} defects and dislocation loop were observed from ...

2004-11-15

186

Kinetic Monte Carlo (KMC) simulations for boron diffusion in ion-implanted crystalline materials  

International Nuclear Information System (INIS)

In this paper, we report kinetic Monte Carlo study on the diffusion behavior of boron in silicon crystal, more particularly on the transient enhanced diffusion (TED) of boron in silicon during implantation and annealing. Firstly, the accuracy of our KMC code was verified by investigating the time evolutionary behavior of interstitial (I) and vacancy (V) when a silicon substrate is implanted with silicon dose with an energy of 10 keV and with a dose of 1 X 10"1"4 ions/cm"2. To investigate the influence of native defects (I, V) on boron diffusion, a single and multi boron markers grown by MBE were employed. The simulation results revealed that the precursor of boron cluster (BI_2) is dominant at the initial stage of annealing, which explains the boron TED phenomenon in terms of the concentration of boron complexes and I, V clusters, respectively. The formation of #left brace#311#right brace# defects and dislocation loop were observed from the ...

2004-11-01

187

Interactions of ion-implantation-induced interstitials with boron at high concentrations in silicon  

Energy Technology Data Exchange (ETDEWEB)

Ion implantation of Si (60 keV, 1{times}10{sup 14}/cm{sup 2}) has been used to introduce excess interstitials into silicon predoped with high background concentrations of B, which were varied between 1{times}10{sup 18} and 1{times}10{sup 19}/cm{sup 3}. Following post-implantation annealing at 740{degree}C for 15 min to allow agglomeration of the available interstitials into elongated {l_brace}311{r_brace} defects, the density of the agglomerated interstitials was determined by plan-view transmission electron microscopy observation of the defects. We report a significant reduction in the fraction of excess interstitials trapped in {l_brace}311{r_brace} defects as a function of boron concentration, up to nearly complete disappearance of the {l_brace}311{r_brace} defects at boron concentrations of 1{times}10{sup 19}/cm{sup 3}. The reduction of the excess interstitial concentration is interpreted in terms of boron-interstitial clustering, and ...

1996-09-01

188

Interactions of ion-implantation-induced interstitials with boron at high concentrations in silicon  

International Nuclear Information System (INIS)

Ion implantation of Si (60 keV, 1x10"1"4/cm"2) has been used to introduce excess interstitials into silicon predoped with high background concentrations of B, which were varied between 1x10"1"8 and 1x10"1"9/cm"3. Following post-implantation annealing at 740 degree C for 15 min to allow agglomeration of the available interstitials into elongated #left brace#311#right brace# defects, the density of the agglomerated interstitials was determined by plan-view transmission electron microscopy observation of the defects. We report a significant reduction in the fraction of excess interstitials trapped in #left brace#311#right brace# defects as a function of boron concentration, up to nearly complete disappearance of the #left brace#311#right brace# defects at boron concentrations of 1x10"1"9/cm"3. The reduction of the excess interstitial concentration is interpreted in terms of boron-interstitial clustering, and implications for transient-enhanced ...

189

Inelastic-energy-loss measurements of multiple N- and M-shell excitations in 0.3- to 1.2-MeV Xe"+-Xe collisions  

International Nuclear Information System (INIS)

The inelastic energy losses for single collisions of Xe"+ ions with Xe targets have been measured for incident ion energies from 0.3 to 1.2 MeV and for scattering angles from 3"0 to 20"0. The energy losses were found to range from 1 to 11 keV with distinct steps at distances of closest approach of 0.22 and 0.12 A. By comparing these data with earlier ionization data by the same authors these steps are shown to be caused by M-shell excitation. Other excitations observed in the ionization data may be attributed to N-shell excitation. The distances of closest approach at which these excitations occur agree well with calculations by Eichler and Wille and co-workers, giving further evidence of the usefulness of Fano and Lichten's one-electron molecular model and these calculations.

190

Direct patterning of gold oxide thin films by focused ion-beam irradiation  

International Nuclear Information System (INIS)

For direct writing of electrically conducting connections and areas into insulating gold oxide thin films a scanning Ar"+ laser beam and a 30 keV Ga"+ focused ion beam (FIB) have been used. The gold oxide films are prepared by magnetron sputtering under argon/oxygen plasma. The patterning of larger areas (dimension 10-100 #mu#m) has been carried out with the laser beam by local heating of the selected area above the decomposition temperature of AuO_x(130-150 C). For smaller dimensions (100 nm to 10 #mu#m) the FIB irradiation could be used. With both complementary methods a reduction of the sheet resistance by 6-7 orders of magnitude has been achieved in the irradiated regions (e.g. with FIB irradiation from 1.5 x 10"7#OMEGA#/#square# to approximately 6 #OMEGA#/#square#). The energy-dispersive X-ray analysis (EDX) show a considerably reduced oxygen content in the irradiated areas, and scanning electron microscopy (SEM), as well as atomic force ...

2000-09-01

191

Direct evidence of the recombination of silicon interstitial atoms at the silicon surface  

Energy Technology Data Exchange (ETDEWEB)

In this experiment, a Si wafer containing four lightly doped B marker layers epitaxially grown by CVD has been implanted with 100 keV Si{sup +} ions to a dose of 2 x 10{sup 14} ions/cm{sup 2} and annealed at 850 deg. C for several times in an RTA system in flowing N{sub 2}. TEM and SIMS analysis, in conjunction with a transient enhanced diffusion (TED) evaluation method based on the kick-out diffusion mechanism, have allowed us to accurately study the boron TED evolution in presence of extended defects. We show that the silicon surface plays a key role in the recombination of Si interstitial atoms by providing the first experimental evidence of the resulting Si{sub int}s supersaturation gradient between the defect region and the surface. Our results indicate an upper limit of about 200 nm for the surface recombination length of Si interstitials at 850 deg. C in a N{sub 2} ambient.

2004-02-01

192

Direct evidence of the recombination of silicon interstitial atoms at the silicon surface  

International Nuclear Information System (INIS)

In this experiment, a Si wafer containing four lightly doped B marker layers epitaxially grown by CVD has been implanted with 100 keV Si"+ ions to a dose of 2 x 10"1"4 ions/cm"2 and annealed at 850 deg. C for several times in an RTA system in flowing N_2. TEM and SIMS analysis, in conjunction with a transient enhanced diffusion (TED) evaluation method based on the kick-out diffusion mechanism, have allowed us to accurately study the boron TED evolution in presence of extended defects. We show that the silicon surface plays a key role in the recombination of Si interstitial atoms by providing the first experimental evidence of the resulting Si_i_n_ts supersaturation gradient between the defect region and the surface. Our results indicate an upper limit of about 200 nm for the surface recombination length of Si interstitials at 850 deg. C in a N_2 ambient.

2004-02-01

193

Boron transient enhanced diffusion in heavily phosphorus doped silicon  

Energy Technology Data Exchange (ETDEWEB)

A study has been made of B transient enhanced diffusion (TED) in heavily P-doped Si using secondary ion mass spectroscopy (SIMS) and positron annihilation spectroscopy (PAS). The P-doped silicon was implanted with boron ions of 40 keV energy to a dose of 3 {times} 10{sup 14} cm{sup {minus}2}, and then annealed at temperatures ranging from 700--1,000 C in a N{sub 2} ambient for varying durations. As P doping concentration increased from 3 {times} 10{sup 19} to 1 {times} 10{sup 20} cm{sup {minus}3}, boron diffusivity and the immobile boron fraction decreased. The experimental results are inconsistent with the predictions of the Fermi-level model and suggest that the clustering between B atoms and Si interstitials should be invoked in order to explain the immobile portion of the B peak during TED.

1997-11-01

194

Atomistic calculations of ion implantation in Si: Point defect and transient enhanced diffusion phenomena  

Energy Technology Data Exchange (ETDEWEB)

A new atomistic approach to Si device process simulation is presented. It is based on a Monte Carlo diffusion code coupled to a binary collision program. Besides diffusion, the simulation includes recombination of vacancies and interstitials, clustering and re-emission from the clusters, and trapping of interstitials. We discuss the simulation of a typical room-temperature implant at 40 keV, 5{times}10{sup 13} cm{sup {minus}2} Si into (001)Si, followed by a high temperature (815{degree}C) anneal. The damage evolves into an excess of interstitials in the form of extended defects and with a total number close to the implanted dose. This result explains the success of the {open_quote}{open_quote}+1{close_quote}{close_quote} model, used to simulate transient diffusion of dopants after ion implantation. It is also in agreement with recent transmission electron microscopy observations of the number of interstitials stored in (311) defects. ...

1996-01-01

195

Atomistic calculations of ion implantation in Si: Point defect and transient enhanced diffusion phenomena  

International Nuclear Information System (INIS)

A new atomistic approach to Si device process simulation is presented. It is based on a Monte Carlo diffusion code coupled to a binary collision program. Besides diffusion, the simulation includes recombination of vacancies and interstitials, clustering and re-emission from the clusters, and trapping of interstitials. We discuss the simulation of a typical room-temperature implant at 40 keV, 5x10"1"3 cm"-"2 Si into (001)Si, followed by a high temperature (815 degree C) anneal. The damage evolves into an excess of interstitials in the form of extended defects and with a total number close to the implanted dose. This result explains the success of the open-quote open-quote+1 close-quote close-quote model, used to simulate transient diffusion of dopants after ion implantation. It is also in agreement with recent transmission electron microscopy observations of the number of interstitials stored in (311) defects. copyright 1996 American Institute ...

196

Valence-electron configuration of Ti and Ni in TixNi1-x alloys from Kbeta-to-Kalpha X-ray intensity ratio studies.  

Science.gov (United States)

Kbeta-to-Kalpha X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of Ti(x)Ni(1-x) (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi (109)Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured Kbeta-to-Kalpha X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other element and/or the rearrangement of electrons between 3d and 4s, ...

2010-01-28

197

Valence-electron configuration of Ti and Ni in TixNi1-x alloys from K?-to-K? X-ray intensity ratio studies  

International Nuclear Information System (INIS)

K?-to-K? X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of TixNi1-x (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi 109Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured K?-to-K? X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other element and/or the rearrangement of electrons between 3d and 4s, 4p states of ...

2010-06-01

198

Alloying effect on K to L shell vacancy transfer probabilities in 3d transition metals  

British Library Electronic Table of Contents (United Kingdom)

The alloying effects on K to L shell vacancy transfer probabilities (?KL) in 3d transition metals have been carried out by X-ray fluorescence studies of various alloy compositions. K X-ray intensity ratios of Ti, Cr, Fe, Co, Ni, and Cu elements in the FexNi1?x, FexCr1?x, NixCr1?x, FexCryNi1?(x+y), TixNi1?x, TixCo1?x, and CoxCu1?x alloys have been measured following excitation by 22.69keV X-rays from a 10 mCi 109Cd radioactive point source and ?KL values for alloying elements have been determined from these ratios. The spectrum of characteristic K-X-ray photons from samples were detected with a high resolution Si(Li) detector coupled to a 4 K multichannel analyzer. The present investigation makes it possible to ...

2010-01-01

199

The enhanced genomic instability was induced by alpha particle and low-energy ion irradiation in somatic cells of Arabidopsis thaliana  

International Nuclear Information System (INIS)

Although low-energy ion radiation has been proven to have a wide range of biological effects and led to fruitful achievements as a new mutagenic source for genetic modification, there still exist some disputes about its mutagenic mechanisms because of its short-penetrating property. In present research, Arabidopsis thaliana transgenic for GUS recombination substrate was used to evaluate the genomic instability induced by irradiations of alpha particle (3.3MeV) and Low-energy-Argon ion (30 KeV). A pronounced effects of alpha particle irradiation to Arabidopsis thaliana seedlings and Argon ion irradiation to seeds on the somatic homologous recombination frequency (sHRF) were reported. The sHRFs increased 1.88-fold and 2.42-fold, respectively, which indicated that the short-penetrating radiation could effectively induce the plant genomic instability in either dry seeds or seedlings with active metabolism. ...

2008-08-12

200

Plasma-based ion implantation and deposition: A review of physics,technology, and applications  

Energy Technology Data Exchange (ETDEWEB)

After pioneering work in the 1980s, plasma-based ion implantation (PBII) and plasma-based ion implantation and deposition (PBIID) can now be considered mature technologies for surface modification and thin film deposition. This review starts by looking at the historical development and recalling the basic ideas of PBII. Advantages and disadvantages are compared to conventional ion beam implantation and physical vapor deposition for PBII and PBIID, respectively, followed by a summary of the physics of sheath dynamics, plasma and pulse specifications, plasma diagnostics, and process modeling. The review moves on to technology considerations for plasma sources and process reactors. PBII surface modification and PBIID coatings are applied in a wide range of situations. They include the by-now traditional tribological applications of reducing wear and corrosion through the formation of hard, tough, smooth, low-friction and ...

2005-05-16

201

Modification of the passivity of iron based alloys through ion implantation  

International Nuclear Information System (INIS)

As an unconventional surface alloying process, ion implantation has been utilized to improve the active-passive behavior and the pitting resistance of martensitic M50 engineering alloy. In a field simulation study, Cr-implantation only at 150 kev to a fluence of 2 x 10"1"7 ions/cm"2 prevented pitting. The best pitting resistance of the steel was obtained with multiple implantations of Cr and Mo. The intermixing effect of high fluence P-implantation into 304 stainless produced an amorphous surface alloy. The removal of the grain boundaries and the uniformity of the resulting structure had a great influence on corrosion properties. REED analysis indicated that the anodic passive films formed on P-implanted 304 stainless steel at 250 mV (SCE) in 0.5M H_2SO_4 was amorphous. Phosphorus and boron were implanted into 316 stainless steel to study the passivity of 316 stainless. Electrochemical experiments were carried out to ...

1764-01-01

202

FABRICATION OF BISMUTH NANOWIRE DEVICES USING FOCUSED ION BEAM MILLING  

International Nuclear Information System (INIS)

In this work, a focused ion beam (FIB) milling process has been developed to fabricate 50 nm Bi nanowire and transistor structures using FEI-200 dual beam FIB system. For the fabrication, 50 nm bismuth film was thermally evaporated through EBL patterned PMMA windows onto SiO_2 substrates with pre-defined contact pads. Bi nanowire widths ranging from 30 nm to 100 nm have been successfully fabricated by milling out unwanted areas using 30 KeV Ga+ ion beam. A single-pixel-line ion beam blanking technique has been utilised to fabricate Bi nanowire as small as 30 nm in diameter and few micrometers long. In order to form good ohmic contacts for sub 50 nm bismuth nanowires, a drill-and-fill process has been developed using FIB to sputter away the surface oxide of bismuth after the in-situ platinum nanowire contacts deposition. To our knowledge, this is the first time a focused ion beam ...

2009-07-23

203

Investigation of techniques to improve continuous air monitors under conditions of high dust loading in environmental setting. 1998 annual progress report  

Energy Technology Data Exchange (ETDEWEB)

'Improvement in understanding of the deposition of ambient dust particles on ECAM (Environmental Continuous Air Monitor) filters, reduction of the alpha-particle interference of radon progeny and other radioactive aerosols in different particle size ranges on filters, and development of ECAM''s with increased sensitivity under dusty outdoor conditions. As of May 1, 1998 (1/2 year into the project) the research-prototype 30-cm pulsed ionization chamber (PIC) is assembled and operational with an alpha particle energy resolution of better than 45 keV for 5-MeV alpha particles. Measurements of spectral resolution for alpha particles from radon decay products have been made as a function of filter type and dust loading conditions. So far, a study of ten filter types has found that the best combination of resolution and throughput is obtained with 3.0 \\265m Millipore fluoropore and 1.0 \\265m Corning FNMB filters. ...

1998-06-01

204

Investigation by XRF and XRD of Zn and Fe in Fe{sub x} Zn{sub 1-x} thin films  

Energy Technology Data Exchange (ETDEWEB)

Fe{sub x}Zn{sub 1-x} alloys were electrochemically deposited on aluminum substrates from a sulfate bath. The K{beta}/K{alpha} x-ray intensity ratios of Zn and Fe in Fe{sub x}Zn{sub 1-x} thin films have been experimentally studied. The energy dispersive x-ray fluorescence (EDXRF) technique was used to measure K x-ray photons. Samples were excited by using 59.5 keV photons emitted by a 50 mCi {sup 241}Am radioactive source. The emitted K x-rays were detected by an Ultra-LEGe detector having a resolution of 150 eV at 5.9 keV. In addition, the effect of bath composition on the phase structure was investigated by x-ray diffraction (XRD) analysis. The composition of the thin films was analyzed by atomic absorption spectrometry analysis. Iron content was shown to strongly affect the structure of Zn-Fe alloys. It was found that the K-shell x-ray intensity ratio changed in Fe{sub x}Zn{sub 1-x} thin films for different values of x. ...

2008-12-15

205

Investigation by XRF and XRD of Zn and Fe in Fex Zn1-x thin films  

International Nuclear Information System (INIS)

FexZn1-x alloys were electrochemically deposited on aluminum substrates from a sulfate bath. The K?/K? x-ray intensity ratios of Zn and Fe in FexZn1-x thin films have been experimentally studied. The energy dispersive x-ray fluorescence (EDXRF) technique was used to measure K x-ray photons. Samples were excited by using 59.5 keV photons emitted by a 50 mCi 241Am radioactive source. The emitted K x-rays were detected by an Ultra-LEGe detector having a resolution of 150 eV at 5.9 keV. In addition, the effect of bath composition on the phase structure was investigated by x-ray diffraction (XRD) analysis. The composition of the thin films was analyzed by atomic absorption spectrometry analysis. Iron content was shown to strongly affect the structure of Zn-Fe alloys. It was found that the K-shell x-ray intensity ratio changed in FexZn1-x thin films for different values of x. The reason for this change may be that the ...

2008-12-01

206

Production of rare earth enriched isotopes and americium 242 using metallphthalocyanines  

International Nuclear Information System (INIS)

A technique of producing radioactive isotopes of rare earth elements (r.e.e.) and carrier free "2"4"2Am is suggested. The technique makes use of ''sandwich'' phthalocya=- nine complexes of r.e.e. and americium placed on sorbent. This is a new type of r.e.e. compounds and actinides (C_3_2H_1_6N_8)_2M (M is a metal ion) which are thermally, radiationally and chemically stable, dissolve well in some organic solvents and do not dissolve in water. Radiation and chemically stable activated carbon is used as a sorbent carrier. After irradiation the target is treated by a weakly acid solution or complex-former solution. Radioactive atoms formed due to (n, #gamma#)-reaction and desoleting the complex because of recoil transfer into the solution. When irradiating in the flux of 10"1"3 neutr./cm"2 x s for 1 hour it is possible to produce radioactive isotopes with the yield from 20 to 90%, for example "1"6"0Tb, ...

207

Operating experience with solidification of radioactive waste by a thin-film evaporator  

Energy Technology Data Exchange (ETDEWEB)

In the nuclear power stations of GDR the rough radioactive waste includes borat-containing evaporator bottoms and spent ion exchanger resins. For its final disposal in deep geological formations (rock salt mines) this waste has to be solidified. The experience of one year lasting operation of a steam heated thin-film evaporator (heating surface 2 m{sup 3}) for evaporator bottoms to be solidified with a solid content of 200-250 g/l are reported on. In short time such amount of water is abstracted from the rough waste that due to the borate content a hot high-viscous product passes from evaporator to waste drum and there solidifies like glass to monolith. The product quality depends on the adjustment of the flow-equilibrium in the evaporator. Boric acid is used as matrix for the radioactive residues. The residual water content of the solidified waste product was about 15-20%, the volume reduction was V{sub f}=5...6. In order ...

1990-01-01

208

Operating experience with solidification of radioactive waste by a thin-film evaporator  

International Nuclear Information System (INIS)

In the nuclear power stations of GDR the rough radioactive waste includes borat-containing evaporator bottoms and spent ion exchanger resins. For its final disposal in deep geological formations (rock salt mines) this waste has to be solidified. The experience of one year lasting operation of a steam heated thin-film evaporator (heating surface 2 m"3) for evaporator bottoms to be solidified with a solid content of 200-250 g/l are reported on. In short time such amount of water is abstracted from the rough waste that due to the borate content a hot high-viscous product passes from evaporator to waste drum and there solidifies like glass to monolith. The product quality depends on the adjustment of the flow-equilibrium in the evaporator. Boric acid is used as matrix for the radioactive residues. The residual water content of the solidified waste product was about 15-20%, the volume reduction was V_f=5...6. In order to be sure ...

1990-06-01

209

Crud behaviors and water chemistry in nuclear reactors  

International Nuclear Information System (INIS)

The deposit of radioactive corrosion products in the cooling systems of nuclear reactors becomes a serious problem for the personnel of facilities. Crud has an important role in the process of depositing radioactive corrosion products. The main components of crud are hematite, magnetite, nickel ferrite and so on, and the particles of these oxide compounds are distributed in water. Most of the behavior of crud are still not known. As for the mechanism of the production of crud, the Potter-Mann model has been proposed. However, the precipitation process of iron ions in water is unknown. The crud is defined as the particles filtered by 0.45 micrometer millipore filters. However, it is not known whether there are crud particles smaller than this size. The crud particles can be adsorbed on the filters by the surface electrochemical interaction. The adsorption of cations to crud particles was studied. The adhesion of crud ...

210

Influence of iron deficiency in the radiopharmaceutical behavior of red blood cells labeled with "9"9"mTc("9"9"mTC-RBC)  

International Nuclear Information System (INIS)

Full text: Red blood cells (RBCs) labeled with "9"9"mTc are commonly used in the evaluation of cardiac function, gastrointestinal tract bleeding, red blood cell volume or splenic sequestration. Generally stannous ion is used as reducing agent. A proposed mechanism is that once the stannous ion (Sn) and the pertechnetate ("9"9"mTc) reach the interior of the RBC, the radionuclide is mainly house in the #beta#-chain of hemoglobin. The aim of this study was to determine if hemoglobin content reduction, an indicator of iron deficiency anemia, could affect the efficiency of RBC labeling and the biological distribution of this radiopharmaceutical. We studied 30 rats fed for 3 weeks after weaning with diets with iron contents of 6.5 ppm (group A), 18 ppm (group B) and 100 ppm (control). For all groups, the labeling yields were always higher than 97%; the percentage of radioactivity was mostly founded in blood with almost negligible ...

2005-11-09

211

Decontamination factors of ceramic filter in radioactive waste incineration system  

International Nuclear Information System (INIS)

A suspension-firing type radioactive waste incineration system is developed and cold demonstration testing of ceramic filters for the system are carried out. The incineration system, which is useful for a wide variety of waste materials, can serve to simplify the facilities and to reduce the costs for waste disposal. The incineration system can be used for drying-processing of concentrated waste liquids and disposal of flame resistant materials including ion exchange resins and rubber, as well as for ordinary combustible solid materials. An on-line backwash system is adopted to allow the ceramic filters to operate stably for a long period of time. For one-step filtering using the ceramic filter, the decontamination factor is greater than 10"5 for the processing of various wastes. In a practical situation, there exist vapor produced by the spray drier and the cladding in used ion exchange resin, which act to increase the ...

212

Absorption studies for selection of low cost materials for management of low level radioactive liquid waste  

International Nuclear Information System (INIS)

Natural minerals and some industrial wastes are used as low cost sorbents for removal of metal ions from effluent streams. Apatite as natural mineral and red mud as an industrial waste have been tested for their sorption properties with respect to two important fission products "1"3"7Cs and "9"0Sr. Their ion exchanging capacity was tested after every 4 hours till 24 hours. The material gets saturated after 4-8 hours. Hence these materials can be considered for treating in treating LLW before discharge, industrial waste treatment and as backfill or admixture material for shallow land repository. (author)

2010-03-01

213

Longitudinal emittance oscillation in a superconducting drift tube linac  

International Nuclear Information System (INIS)

In drift tube linacs a beam energy spread results form the finite beam size. Radial variation of the axial accelerating field induces a beam energy spread, which, in general, will accumulate as the beam passes through successive drift tubes. This paper shows that under some conditions of periodic transverse focusing and longitudinal phase focusing, the correlation between the longitudinal and transverse motion can be used to correct the energy spread. The process of achieving such a correction is first described in a simplified situation, and then demonstrated for a particular tuning using a ray-tracing program which models a low velocity and low charge state linac designed for radioactive ion beams.

1995-05-01

214

First results from the Lund NMP particle detector system  

International Nuclear Information System (INIS)

The design and first results from a Double Sided Silicon Strip Detector (DSSSD) recently installed at the Lund Nuclear Microprobe facility (NMP) are presented. The detector has 64 sector strips and 32 ring strips, which in combination give more than 2000 detector cells, each with characteristics comparable with a standard surface barrier detector (SBD). The detector has been tested both with radioactive sources and with different ion beams and energies. The most striking features are the high rate virtually pile-up free operation and also the possibility of detailed measurement of angular distributions.

2009-06-15

215

First results from the Lund NMP particle detector system  

British Library Electronic Table of Contents (United Kingdom)

The design and first results from a Double Sided Silicon Strip Detector (DSSSD) recently installed at the Lund Nuclear Microprobe facility (NMP) are presented. The detector has 64 sector strips and 32 ring strips, which in combination give more than 2000 detector cells, each with characteristics comparable with a standard surface barrier detector (SBD). The detector has been tested both with radioactive sources and with different ion beams and energies. The most striking features are the high rate virtually pile-up free operation and also the possibility of detailed measurement of angular distributions.

2009-01-01

216

Sub-0.1 #mu#m line fabrication by Focused ion beam and columnar structural Se-Ge resist  

International Nuclear Information System (INIS)

As a method to enhance the sensitivity (S) of an inorganic resist for focused-ion-beam (FIB), lithography, sub-0.1 #mu#m patterning properties of a columnar structural #alpha#-Se_7_5Ge_2_5 resist have been investigated using 30 keV low-energy Ga"+-FIB exposure and CF_4 reactive-ion etching (RIE). development. The Se_7_5Ge_2_5 thin films were 60 .deg. and 80 .deg. -obliquely deposited on Si substrate and parts of the films were annealed for several minutes at the glass transition temperature (T_g=#approx#220 .deg. C). Columnar structures with the angles of approximately 40 .deg. and 65 .deg. are observed in 60 .deg. and 80 .deg. -obliquely deposited films, respectively, and they disappear after annealing. Despite the disappearance of the columnar structures, a critical decrease in thickness is not observed. For the FIB exposures with a beam diameter of #approx#0.1#mu#m and around the threshold dose, the negative-type fine ...

1998-11-01

217

Development of a high-current microwave ion source for proton linac application systems  

International Nuclear Information System (INIS)

A microwave hydrogen ion source was developed to improve reliability, and to increase operation time of proton linac application systems. The ion source needs no filament in the discharge chamber, which leads to better reliability and less maintenance time. The developed source produced a maximum hydrogen ion beam current of 70 mA (high current density of 360 mA/cm2, beam energy of 30 keV) with a 5 mm diam extraction aperture and 1.2 kW microwave power. The proton fraction was increased with an increase in rf power and reached around 90% at 1 kW. Measured 90% beam normalized emittance was 0.4 #pi# mm mrad. Rise times of rf power and beam current to 90% of the final values were about 30 and 35 #mu#s, respectively, at a pulse operation mode with 400 #mu#s pulse width and 100 Hz repetition rate. The dynamic range of beam currents was enlarged (3-63 mA) in the pulse mode with a modified rf wave form to ...

2004-05-01

218

Status of the WAND (Waste Assay for Nonradioactive Disposal) project as of July 1997  

Energy Technology Data Exchange (ETDEWEB)

The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole system and to perform the data analysis. WAND system minimum detectable activities (MDAs) for point sources ...

1998-03-01

219

Measurement of K x-ray intensity ratio of tin, gadolinium and dysprosium  

International Nuclear Information System (INIS)

Full text: Measurement of K_#beta# to K_#alpha# x-ray intensity ratios are important not only in the field of atomic physics, radiation physics and medical physics, but also to test the validity of assumptions made in the theoretical prediction. The intensity ratios can also give information on the effect of physical and chemical environment of the element in the compound. Many investigators have adopted a single and double reflection geometries to measure the K_#beta# to K_#alpha# x ray intensity ratios to understand the effect of physical and chemical environment on x-ray fluorescence. The targets are excited by a radioactive source of having activity of the order 100 MBq. in order to carry out accurate measurement K_#beta# to K_#alpha# x-ray intensity ratios, we have develop 2#pi# geometrical configuration method : placing a target right on the surface of the detector facing the target to measure the K shell fluorescence parameters such as fluorescence yield, ...

2003-11-01

221

Radiation protection and the management of radioactive waste in the oil and gas industry  

CERN Document Server

Radiation protection and the management of radioactive waste in the oil and gas industry

2003-01-01

222

Liquid Radioactive Wastes Processing  

International Science & Technology Center (ISTC)

Methods of Decontamination, Utilization, and Deactivation of Liquid Radioactive Wastes

223

Decomissioning Strategies for Facilities Using Radioactive Material  

CERN Document Server

Decomissioning Strategies for Facilities Using Radioactive Material

2007-01-01

224

Study of silicon damage caused by ultra-low energy boron implantation  

International Nuclear Information System (INIS)

Ultra-shallow junction formation in deep submicron Si devices is limited by anomalous diffusion of the dopant, which is related to the release of interstitials from defect clusters formed during the implantation of energetic ions or the subsequent annealing. The work described in this dissertation is concerned with the effects of low energy B ion implantation, especially damage formation, clustering and its annealing. After a review of the stopping and ranges of energetic ions in Si, the formation of implant damage, in particular of point defects, their migration, agglomeration and annihilation, including the involvement of dopant ions, is considered. A description of the Salford ultra low energy implanter is given and the main analysis technique, medium ion energy scattering (MEIS) reviewed. Additional analytical techniques used, such as secondary ion mass ...

225

Ion exchange at TNX using the SKID unit  

Energy Technology Data Exchange (ETDEWEB)

An ion exchange unit has been manufactured for WSRC by British Nuclear Fuels, Ltd. This unit consists of three columns, ancillary valving, pumps, lines, and computer controls. It has been delivered to TNX for use in testing a cesium-specific ion exchange resin, developed at WSRC as a potential second generation process for the decontamination of Defense Waste Processing Facility (DWPF) supernate. This resin also has Department of Energy applications at both Oak Ridge and Hanford. Oak Ridge is interested in decontaminating the Melton Valley storage tank supernate, while Hanford is interested in decontaminating the 101-AW and 101-SY supernate streams. Another potential developmental interest is the Savannah River Site (SRS) DWPF recycle stream. The three primary waste streams of interest are the Oak Ridge, Hanford, and SRS, SWPF supernate streams. For these three waste streams, the cesium decontamination factor (DF) will be measured for a ...

1993-10-21

226

Strong ionizing events distributed along medium energy #alpha# particle tracks recorded in nuclear emulsion  

International Nuclear Information System (INIS)

Track analysis of medium energy #alpha# particle trajectories recorded in fine grain nuclear emulsion submitted to specific intensifying treatments led to the observation of strong ionizing events (SIE) sticking out of the primary's track core. Preliminary determinations showed that the number of SIEs increases with the primary's energy, and that their production is of more than one order of magnitude higher than the number of Rutherford recoils. The presence of SIEs on monoenergetic #alpha# tracks also has a significant influence on the measured range distribution, which, expressed in terms of energy loss, results in a mean contribution to the total energy loss of far reaching (SIEs (radial spread >= 0.458 #mu#m) of proportional 25 keV per 13.6 MeV #alpha# particle, instead of 0.75 keV in the case where only the Rutherford interactions are taken into account. Measurements carried out in detectors enriched with gelatin indicate an increase ...

227

Molecular dynamics studies of silicon ion implantation  

Energy Technology Data Exchange (ETDEWEB)

Results are presented of molecular dynamics (MD) studies of 1-10 keV displacement cascades in silicon. At these energies, the simulations couple directly to experimental observations of low energy implantation in silicon for shallow junction formation. The simulations are performed with the Stillinger-Weber potential for silicon in computational cells with up to 3.5x10{sup 5} atoms. The author employs periodic boundary conditions in the [100] and [010] directions and a free surface on the top (001) plane. The author discusses the results in terms of the structural evolution and the dynamics of the cascade zones. For sufficiently high energy recoils (>2 KeV), the cascades produce locally molten zones that result in the formation of amorphous silicon pockets upon recrystallization. Frenkel pairs are also produced during the cascade, although their number is very small (less than 10% of the binary collision predictions). Upon annealing of the ...

1994-12-31

228

Total interaction cross sections and effective atomic numbers of some biologically important compounds containing H, C, N and O in the energy range 6.4-136 keV  

International Nuclear Information System (INIS)

The total interaction cross sections (#sigma#_t) of some sugars and amino acids and five elements: lithium, carbon, oxygen, aluminium and calcium have been measured for 6.4 keV, 13.95 keV, 14.4 keV, 17.74 keV, 24.14 keV, 30.8 keV, 35 keV, 59.54 keV, 81 keV, 122 keV and 136 keV photons in a narrow beam good geometry set up, by using high resolution detectors such as a Si-PIN diode detector and a high purity germanium detector. The #sigma#_t values have been used in a matrix method to evaluate the effective atomic numbers Z_e_f_f of the samples from their effective atomic cross sections #sigma#_a. The effective atomic cross section of a sample #sigma#_a is the total interaction cross section divided by the total number of atoms of all types in it. Further, a ...

2007-09-28

229

XPS study of passive films formed on molybdenum-implanted austenitic stainless steels  

Energy Technology Data Exchange (ETDEWEB)

Austenitic stainless steels have been implanted with molybdenum ions (Mo[sup +], 100 keV, 2.5 x 10[sup 16] atoms cm[sup -2]). The implanted material has been characterized by XPS and RBS. The implanted region has a thickness of [approx] 1000 A with a maximum molybdenum concentration of [approx] 9 at.% Mo located at [approx] 210 A from the surface. The effects of implanted molybdenum on the passivation of the alloy in 0.5 M H[sub 2]SO[sub 4] have been investigated by electrochemistry and XPS. After XPS analysis the samples were transferred without exposure to air into a glove-box with an inert atmosphere. The electrochemical behaviour of the alloy is significantly modified by the implanted molybdenum. The major effect is that the activation peak disappears. A bilayer structure (outer hydroxide/inner oxide) of the passive film is observed for both the implanted and non-implanted alloys and the thicknesses of the films are similar. On the ...

1992-06-01

230

XPS study of passive films formed on molybdenum-implanted austenitic stainless steels  

International Nuclear Information System (INIS)

Austenitic stainless steels have been implanted with molybdenum ions (Mo"+, 100 keV, 2.5 x 10"1"6 atoms cm"-"2). The implanted material has been characterized by XPS and RBS. The implanted region has a thickness of #approx# 1000 A with a maximum molybdenum concentration of #approx# 9 at.% Mo located at #approx# 210 A from the surface. The effects of implanted molybdenum on the passivation of the alloy in 0.5 M H_2SO_4 have been investigated by electrochemistry and XPS. After XPS analysis the samples were transferred without exposure to air into a glove-box with an inert atmosphere. The electrochemical behaviour of the alloy is significantly modified by the implanted molybdenum. The major effect is that the activation peak disappears. A bilayer structure (outer hydroxide/inner oxide) of the passive film is observed for both the implanted and non-implanted alloys and the thicknesses of the films are similar. On the implanted alloy the outer ...

1991-10-01

231

Using Gamma-Ray Burst Prompt Emission to Probe Relativistic Shock Acceleration  

CERN Document Server

It is widely accepted that the prompt transient signal in the 10 keV - 10 GeV band from gamma-ray bursts (GRBs) arises from multiple shocks internal to the ultra-relativistic expansion. The detailed understanding of the dissipation and accompanying acceleration at these shocks is a currently topical subject. This paper explores the relationship between GRB prompt emission spectra and the electron (or ion) acceleration properties at the relativistic shocks that pertain to GRB models. The focus is on the array of possible high-energy power-law indices in accelerated populations, highlighting how spectra above 1 MeV can probe the field obliquity in GRB internal shocks, and the character of hydromagnetic turbulence in their environs. It is emphasized that diffusive shock acceleration theory generates no canonical spectrum at relativistic MHD discontinuities. This diversity is commensurate with the significant range of spectral indices discerned in ...

2010-01-01

232

Low energy boron implantation in silicon: (1) reduction of channeling tail by careful alignments. (2) Transient diffusion during rapid thermal annealing  

Energy Technology Data Exchange (ETDEWEB)

An attempt was made to minimize the channeling tail by implantation along a random equivalent direction following a careful alignment of the target. In order to analytically determine the random equivalent directions, critical angles for channeling were mapped on a stereogram. Boron ions with energies of 17 and 45 keV are implanted along specified directions determined from the map. The depth distribution of the dopant is profiled by SIMS and the effects of water orientation upon the channeling tail are noted. Industrial common use of a 7/sup 0/ tilt is not optimum. However, implantation with the wafer tilted at 5.5 +/- 0.5/sup 0/ from the surface normal and rotated at 7.0 +/- 0.5/sup 0/ from a (100) plane shows the least channel-tail compared to implantation along other directions. Rapid thermal annealing (RTA) is a promising annealing method for shallow junction formation. Transient enhanced diffusion of implanted boron is observed. Two ...

1985-01-01

233

Low energy boron implantation in silicon: (1) reduction of channeling tail by careful alignments. (2) Transient diffusion during rapid thermal annealing  

International Nuclear Information System (INIS)

An attempt was made to minimize the channeling tail by implantation along a random equivalent direction following a careful alignment of the target. In order to analytically determine the random equivalent directions, critical angles for channeling were mapped on a stereogram. Boron ions with energies of 17 and 45 keV are implanted along specified directions determined from the map. The depth distribution of the dopant is profiled by SIMS and the effects of water orientation upon the channeling tail are noted. Industrial common use of a 7"0 tilt is not optimum. However, implantation with the wafer tilted at 5.5 +/- 0.5"0 from the surface normal and rotated at 7.0 +/- 0.5"0 from a (100) plane shows the least channel-tail compared to implantation along other directions. Rapid thermal annealing (RTA) is a promising annealing method for shallow junction formation. Transient enhanced diffusion of implanted boron is observed. Two different mechanisms ...

234

Lifetime and {ital g}-factor measurements of the 11{sup {minus}} isomer in {sup 92}Tc  

Energy Technology Data Exchange (ETDEWEB)

The half-life ({ital T}{sub 1/2}) and {ital g} factor of the 2002 keV 11{sup {minus}} isomer in the odd-odd nucleus {sup 92}Tc produced by the pulsed heavy-ion reaction {sup 68}Zn({sup 28}Si,{ital p}3{ital n}){sup 92}Tc have been measured using time differential perturbed angular distribution method. The measured {ital T}{sub 1/2} value is 3.15(20) ns. From the observed spin precession frequency {omega}{sub {ital L}} of a {sup 92}Tc recoil implanted into a ferromagnetic Ni host, we obtain the {ital g} factor to be 0.806(20). The measured value of the {ital g} factor is in good agreement with a shell model analysis carried out using {pi}({ital p}{sub 1/2}{ital g}{sub 9/2}) and {nu}({ital p}{sub 1/2}{ital g}{sub 9/2}) orbitals for the proton particles and neutron holes outside the {sup 88}Sr core. {copyright} {ital 1996 The American Physical Society.}

1996-12-01

235

Influence of fluorine on the simulation of the transient enhanced diffusion of 15 keV BF{sub 2}{sup +} ion implantation into silicon  

Energy Technology Data Exchange (ETDEWEB)

We have simulated the transient enhanced diffusion (TED) of boron fluoride (BF{sub 2}{sup +}) implanted in crystalline and germanium amorphized silicon. Based on recently published models, the effect of fluorine on boron diffusion in silicon has been introduced and a modelling has been suggested. In order to simulate the boron experimental profiles, we have assumed that fluorine forms clusters involving interstitial boron which reduces the junction depth. Experimental results indicate that fluorine behaviour depends on amorphization energy. Moreover, even no germanium preamorphization is performed, silicon is still amorphized by fluorine species. Hence, BF{sub 2}{sup +} implantation leads to an amorphous/crystalline (a/c) interface near the surface. An improvement of published models is suggested taking into account fluorine effects. The simulations satisfactory reproduce the SIMS experimental profiles for a large scale of experimental conditions.

2002-01-01

236

Boron-enhanced diffusion of boron from ultralow-energy ion implantation  

Energy Technology Data Exchange (ETDEWEB)

We have investigated the diffusion enhancement mechanism of boron-enhanced diffusion (BED), wherein boron diffusivity is enhanced four to five times over the equilibrium diffusivity at 1050&hthinsp;{degree}C in the proximity of a silicon layer containing a high boron concentration. It is demonstrated that BED is driven by excess interstitials injected from the high boron concentration layer during annealing. For evaporated layers, BED is observed above a threshold boron concentration between 1{percent} and 10{percent}, though it appears to be closer to 1{percent} for B-implanted layers. For sub-keV B implants above the threshold, BED dominates over the contribution from transient-enhanced diffusion to junction depth. For 0.5 keV B, this threshold implantation dose lies between 3{times}10{sup 14} and 1{times}10{sup 15} cm{sup {minus}2}. It is proposed that the excess interstitials responsible for BED are produced during the formation of a silicon boride phase in ...

1999-04-01

237

Boron-enhanced diffusion of boron from ultralow-energy ion implantation  

International Nuclear Information System (INIS)

We have investigated the diffusion enhancement mechanism of boron-enhanced diffusion (BED), wherein boron diffusivity is enhanced four to five times over the equilibrium diffusivity at 1050 ampersand hthinsp;degree C in the proximity of a silicon layer containing a high boron concentration. It is demonstrated that BED is driven by excess interstitials injected from the high boron concentration layer during annealing. For evaporated layers, BED is observed above a threshold boron concentration between 1% and 10%, though it appears to be closer to 1% for B-implanted layers. For sub-keV B implants above the threshold, BED dominates over the contribution from transient-enhanced diffusion to junction depth. For 0.5 keV B, this threshold implantation dose lies between 3x10"1"4 and 1x10"1"5 cm"-"2. It is proposed that the excess interstitials responsible for BED are produced during the formation of a silicon boride phase in the high B concentration layers. copyright 1999 ...

1999-04-01

238

Atomic masses of "6Li,"2"3Na,"3"9","4"1K,"8"5","8"7Rb, and "1"3"3Cs  

International Nuclear Information System (INIS)

The atomic masses of the alkali-metal isotopes "6Li,"2"3Na,"3"9","4"1K,"8"5","8"7Rb, and "1"3"3Cs have been obtained from measurements of cyclotron frequency ratios of pairs of ions simultaneously trapped in a Penning trap. The results, with one standard deviation uncertainty, are: M("6Li)=6.015 122 887 4(16)u,M("2"3Na)=22.989769 282 8(26)u,M("3"9K)=38.963 706 485 6(52)u,M("4"1K)=40.961 825 257 4(48)u,M("8"5Rb)=84.911 789739(9)u,M("8"7Rb)=86.909 180 535(10)u, and M("1"3"3Cs)=132.905 451 963(13)u. Our mass of "6Li yields an improved neutron separation energy for "7Li of 7251.1014(45) keV.

2010-10-01

239

The characteristics of surface oxidation and corrosion resistance of nitrogen implanted zircaloy-4  

International Nuclear Information System (INIS)

This work is concerned with the development and application of ion implantation techniques for improving the corrosion resistance of zircaloy-4. The corrosion resistance in nitrogen implanted zircaloy-4 under a 120 keV nitrogen ion beam at an ion dose of 3 x 10"1"7 cm"-"2 depends on the implantation temperature. The characteristics of surface oxidation and corrosion resistance were analyzed with the change of implantation temperature. It is shown that as implantation temperature rises from 100 to 724 C, the colour of specimen surface changes from its original colour to light yellow at 100 C, golden at 175 C, pink at 300 C, blue at 440 C and dark blue at 550 C. As the implantation temperature goes above 640 C, the colour of surface changes to light black, and the surface becomes a little rough. The corrosion resistance of zircaloy-4 implanted with nitrogen is sensitive to the implantation temperature. ...

240

Focused ion beam damage to MOS integrated circuits  

Energy Technology Data Exchange (ETDEWEB)

Commercial focused ion beam (FIB) systems are commonly used to image integrated circuits (ICS) after device processing, especially in failure analysis applications. FIB systems are also often employed to repair faults in metal lines for otherwise functioning ICS, and are being evaluated for applications in film deposition and nanofabrication. A problem that is often seen in FIB imaging and repair is that ICS can be damaged during the exposure process. This can result in degraded response or out-right circuit failure. Because FIB processes typically require the surface of an IC to be exposed to an intense beam of 30--50 keV Ga{sup +} ions, both charging and secondary radiation damage are potential concerns. In previous studies, both types of effects have been suggested as possible causes of device degradation, depending on the type of device examined and/or the bias conditions. Understanding the causes of this damage is ...

2000-05-10

241

Effect of helium and hydrogen production on hardness of F82H steel irradiated by dual/triple ion beams  

International Nuclear Information System (INIS)

Effect of helium and hydrogen production on radiation-hardening of F82H irradiated by dual or triple beam condition were investigated. The specimens used were four types of ferritic martensitic steels of F82H-std (Fe-8Cr-2W-0.2V-0.04Ta-0.1C) steels tempered at 750degC for 60 minutes, 20% cold worked F82H steel, F82H tempered for 10 minutes and non-tempered F82H steels. The irradiation was performed at 450degC to 50 dpa under simultaneous dual beams of 10.5 MeV Fe"3"+ and 1.05 MeV He"+ or triple beams of those and 380 keV H"+ ions. The ratios of He (appm)/dpa and H(appm)/dpa were 15 nad 15 (or 150) for dual and triple ion beams. The hardness of the irradiated specimens measured at room temperature using a micro indentation after the irradiations. The hardness in these F82H steels irradiated at 450degC to 18 dpa under triple beam irradiation was harder than that under dual beam irradiation. Irradiation softening and hardening ...

2003-03-01

242

Boron depth profiles and residual damage following rapid thermal annealing of low-temperature BSi molecular ion implantation in silicon  

Energy Technology Data Exchange (ETDEWEB)

The influence of substrate temperature on both the implantation and post-annealing characteristics of molecular-ion-implanted 5 x 10{sup 14} cm{sup -2} 77 keV BSi in silicon was investigated in terms of boron depth profiles and damage microstructures. The substrate temperatures under investigation consisted of room temperature (RT) and liquid nitrogen temperature (LT). Post-annealing treatments were performed using rapid thermal annealing (RTA) at 1050 deg, C for 25 s. Boron depth profiles and damage microstructures in both the as-implanted and as-annealed specimens were determined using secondary ion mass spectrometry (SIMS) and transmission electron microscopy (TEM), respectively. The as-implanted results revealed that, compared to the RT specimen, the LT specimen yields a shallower boron depth profile with a reduced tail into the bulk. An amorphous layer containing a smooth amorphous-to-crystalline (a/c) interface is ...

2007-08-15

243

Apoferritin-Templated Yttrium Phosphate Nanoparticle Conjugates for Radioimmunotherapy of Cancers  

Energy Technology Data Exchange (ETDEWEB)

We report a templated-synthetic approach based on apoferritin to prepare radionuclide nanoparticle (NP) conjugates. Non-radioactive yttrium (89Y) was used as model target and surrogate for radioyttrium (90Y) to prepare the nanoparticle conjugate. The center cavity and multiple channel structure of apoferritin offer a fast and facile method to precipitate yttrium phosphate by diffusing yttrium and phosphate ions into the cavity of apofrritin, resulting a core-shell nanocomposite. The yttrium phosphate/apoferritin nanoparticle was functionalized with biotin for further application. The synthesized nanoparticle was characterized by transmission electron microscopy (TEM) and x-ray photoelectron spectroscopy (XPS). We found that the resulting nanoparticles were uniform in size, with a diameter of around 8 nm. We tested the pre-targeting capability of the biotin-modified yttrium phosphate/apoferritin nanoparticle (yttrium phosphate/apoferritin ...

2008-05-01

244

DEVELOPMENT OF PROTOTYPE TITANATE ION EXCHANGE LOADED MEMBRANES FOR STRONTIUM, CESIUM AND ACTINIDE DECONTAMINATION FROM AQUEOUS MEDIA  

International Nuclear Information System (INIS)

We have successfully incorporated high surface area particles of titanate ion exchange materials (monosodium titanate and crystalline silicotitanate) with acceptable particle size distribution into porous and inert support membrane fibrils consisting of polytetrafluoroethylene (Teflon(reg_sign)), polyethylene and cellulose materials. The resulting membrane sheets, under laboratory conditions, were used to evaluate the removal of surrogate radioactive materials for cesium-137 and strontium-90 from high caustic nuclear waste simulants. These membrane supports met the nominal requirement for nonchemical interaction with the embedded ion exchange materials and were porous enough to allow sufficient liquid flow. Some of this 47-mm size stamped out prototype titanium impregnated ion exchange membrane discs was found to remove more than 96% of dissolved cesium-133 and strontium-88 from a caustic nuclear waste ...

2008-05-30

245

Complex Spatio-Spectral Structure of Diffuse X-Ray emission in the ...  

Science.gov (United States)

SN 1987A: Soft X-Ray Intensity Ratio. 2002-12 to 2000-12. 2005-7 to 2002-12. Contours: 2002-12. (0.5 2 keV). (0.5 2 keV). Contours: 2005-7 ...

246

Radioanalytical study of the chromate conversion coating formed on aluminium  

Energy Technology Data Exchange (ETDEWEB)

Phosphate/chromate and accelerated chromate coatings were produced on commercially available aluminium. The Cr, P and Fe components of the conversion coatings were determined by radioactive tracer technique. The tracer technique was combined with ion-exchange and film-sectioning methods to determine the chromium(III)/total chromium ratio in the accelerated chromate coating. It was found that during the acidic dissolution of the conversion coating the chromium(III)/total chromium ratio may suffer changes. The film-forming components in the metal/bath interface are supersaturated and deposited onto the aluminium. The identified components of the accelerated chromate coatings are Cr(OH)sub(3), Cr(OH)CrOsub(4) and Crsub(4)(Fe(CN)sub(6))sub(3) and the chromium(III)/total chromium ratio was found to be cca. 2/3. (author). 11 refs.; 5 figs.

1985-09-16

247

Electron capture decay of sup 203 Pb  

Energy Technology Data Exchange (ETDEWEB)

Intensities of {gamma}-transitions emerging from the EC decay of {sup 203}Pb were measured precisely. The obtained relative {gamma}-intensities are 100%(279.2keV), 4.14+-0.08%(401.3keV) and 0.932+-0.022%(680.5keV). The 279.2 and 680.5keV level feeding {beta}-branching ratios were deduced to be 95.3+-0.1 and 4.7+-0.1% respectively. {sup 203}Pb is suggested for calibration purposes. (author).

1989-01-01

248

8"+ isomers in N=48 isotones and E2 polarization charges  

International Nuclear Information System (INIS)

... charges energy levels gamma spectra half-life isomeric nuclei kev range

1972-05-01

249

Performance of the gas-jet transport system coupled to the RIKEN gas-filled recoil ion separator GARIS for the 238U (22Ne, 5n)255No reaction  

International Nuclear Information System (INIS)

The performance of the gas-jet transport system coupled to the RIKEN gas-filled recoil ion separator GARIS was investigated using 255No produced in the 238U(22Ne, 5n)255No reaction. Alpha particles of 255No separated with GARIS and transported by the gas-jet system were measured with a rotating wheel apparatus for ? spectrometry under low background condition. The high gas-jet efficiencies of about 75% were independent of the recoil ranges of 255No in the gas-jet chamber. The present results suggest that the GARIS/gas-jet system is a promising tool for the next-generation superheavy element chemistry: (1) the background radioactivities of unwanted reaction products are strongly suppressed, (2) the intense beam is absent in the gas-jet chamber and hence the high gas-jet efficiency is achieved, and (3) the beam-free condition also allows for investigations of new chemical systems. (author)

2008-08-01

250

Distribution of naturally occurring radionuclides activity concentration in East Malaysian marine sediment  

Energy Technology Data Exchange (ETDEWEB)

Studies of naturally occurring radioactive materials (NORM) distribution of {sup 226}Ra, {sup 228}Ra and {sup 40}K in East Malaysia were carried out as part of a marine coastal environment project. The results of measurements will serve as baseline data and background reference level for Malaysia coastlines. Sediments from 21 coastal locations and 10 near shore locations were collected for analyses. The samples were dried, finely ground, sealed in a container and stored for a minimum of 30 days to establish secular equilibrium between {sup 226}Ra and {sup 228}Ra and their respective radioactive progenies. They were counted using a high-purity germanium (HPGe) spectrometer covering the respective progeny energy peak. For {sup 40}K, the presence of this was measured directly via its 1460 keV energy peak. The concentration of {sup 226}Ra, {sup 228}Ra and {sup 40}K in samples obtained from coastal Sarawak ranged between 23 and ...

2009-04-15

251

Fusion Reactor Radioactive Waste Management.  

Science.gov (United States)

Quantities and compositions of non-tritium radioactive waste are estimated for some current conceptual fusion reactor designs, and disposal of large amounts of radioactive waste appears necessary. Although the initial radioactivity of fusion reactor and f...

1976-01-01

252

Cyclotron Production of Radioisotopes  

International Science & Technology Center (ISTC)

Production of Radioactive Isotopes in Republic of Kasakhstan.

253

Difference in the effects produced by non-radioactive and radioactive calcium  

International Nuclear Information System (INIS)

... aluminum calcium calcium 45 cations citric acid corrosion inhibition radiation

254

Effect of nitrogen segregation on TED and loss of phosphorus in CZ-Si  

Energy Technology Data Exchange (ETDEWEB)

Transient enhanced diffusion (TED) and dose loss (pile-up) are investigated for phosphorus-implanted samples covered with both oxide and nitride films. P ions were implanted into p-type (1 0 0) CZ-Si (dose 5x10{sup 13} cm{sup -3}, 100 keV) through a chemical vapor deposition (CVD) Si{sub 3}N{sub 4} film. For a half of samples, Si{sub 3}N{sub 4} was etched off and SiO{sub 2} films were grown by CVD. Both samples were annealed for 20-360 min at 700 deg. C. Diffusivity of P and the dose loss were estimated based on the secondary-ion mass spectrometry (SIMS) P profiles. Both Si/Si{sub 3}N{sub 4} and Si/SiO{sub 2} interfaces were investigated with transmission electron microscopy (TEM) and electron energy-loss spectroscopy (EELS). There is no significant difference in P diffusivity between the SiO{sub 2} and Si{sub 3}N{sub 4} films for the present annealing condition of 700 deg. C for 20-360 min. Regarding dose loss, a distinct ...

2002-01-01

255

Effect of nitrogen segregation on TED and loss of phosphorus in CZ-Si  

International Nuclear Information System (INIS)

Transient enhanced diffusion (TED) and dose loss (pile-up) are investigated for phosphorus-implanted samples covered with both oxide and nitride films. P ions were implanted into p-type (1 0 0) CZ-Si (dose 5x10"1"3 cm"-"3, 100 keV) through a chemical vapor deposition (CVD) Si_3N_4 film. For a half of samples, Si_3N_4 was etched off and SiO_2 films were grown by CVD. Both samples were annealed for 20-360 min at 700 deg. C. Diffusivity of P and the dose loss were estimated based on the secondary-ion mass spectrometry (SIMS) P profiles. Both Si/Si_3N_4 and Si/SiO_2 interfaces were investigated with transmission electron microscopy (TEM) and electron energy-loss spectroscopy (EELS). There is no significant difference in P diffusivity between the SiO_2 and Si_3N_4 films for the present annealing condition of 700 deg. C for 20-360 min. Regarding dose loss, a distinct different behavior was observed. In case of the SiO_2 cover ...

2002-01-01

256

Valence-electron configuration of Ti and Ni in Ti{sub x}Ni{sub 1-x} alloys from K{beta}-to-K{alpha} X-ray intensity ratio studies  

Energy Technology Data Exchange (ETDEWEB)

K{beta}-to-K{alpha} X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of Ti{sub x}Ni{sub 1-x} (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi {sup 109}Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured K{beta}-to-K{alpha} X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other element and/or the rearrangement of electrons ...

2010-06-15

257

Structure of the triplet of low-lying states in sup 101 Mo  

Energy Technology Data Exchange (ETDEWEB)

The properties of the triplet of low-lying states in {sup 101}Mo have been studied through spectroscopy of the {gamma} radation following thermal neutron capture in {sup 100}Mo and {beta}-decay of {sup 101}Nb and through a measurement of the proton angular distributions in the {sup 100}Mo(d, p) reaction with 14 MeV deuteron energy. The half-lives of the 13.5 keV state and the 57.0 keV 5/2{sup +} state have been measured as 226(7) and 133(7) ns, respectively. These values and the quadrupole/dipole mixing ratios of the 13.5 keV and 43.5 keV transitions yield spin and parity 3/2{sup +} for the 13.5 keV level. The E2 components in the 13.5 (3/2{sup +}->1/2{sup +}) and 43.5 keV (5/2{sup +}->3/2{sup +}) transitions are {le} 8x10{sup -4} and 54(9)%, respectively. The possibility of an additional state near to the 57.0 keV level is discussed. ...

1991-06-01

258

Structure of the triplet of low-lying states in "1"0"1Mo  

International Nuclear Information System (INIS)

The properties of the triplet of low-lying states in "1"0"1Mo have been studied through spectroscopy of the #gamma# radation following thermal neutron capture in "1"0"0Mo and #beta#-decay of "1"0"1Nb and through a measurement of the proton angular distributions in the "1"0"0Mo(d, p) reaction with 14 MeV deuteron energy. The half-lives of the 13.5 keV state and the 57.0 keV 5/2"+ state have been measured as 226(7) and 133(7) ns, respectively. These values and the quadrupole/dipole mixing ratios of the 13.5 keV and 43.5 keV transitions yield spin and parity 3/2"+ for the 13.5 keV level. The E2 components in the 13.5 (3/2"+#->#1/2"+) and 43.5 keV (5/2"+#->#3/2"+) transitions are #<=# 8x10"-"4 and 54(9)%, respectively. The possibility of an additional state near to the 57.0 keV level is discussed. IBFM/PTQM calculations, taking into ...

259

Solid state diffusion in metal silicides  

International Nuclear Information System (INIS)

Radioactive "3"1Si was used as a marker to study metal silicide formation. Activity profiles in the silicides were measured by a combination of ion beam sputtering, radioactivity counting and Rutherford backscattering of charged nuclear particles. It was found that the metal is the diffusing species during Co_2Si, Pt_2Si, NiSi and PtSi formation, while silicon diffuses during CrSi_2, TiSi_2 and ZrSi_2 formation. Silicon was also found to be the diffusing species during second phase formation of CoSi from Co_2Si. However, in this case it was established that the silicon diffuses by a grain boundary and/or interstitial mechanism. Both the metal and silicon diffuse during Ni_2Si and Pd_2Si formation. In an attempt to interpret complex radioactivity profiles a computer program, simulating various diffusion mechanisms during both first and second phase silicide formation, was written. A numerical approach ...

260

Review of JT-60U experimental results from February to October, 1999  

International Nuclear Information System (INIS)

In 1999, the plasma parameters of reversed shear (RS) plasmas had been extended in 1) DT-equivalent fusion power gain Q_D_T"e"q - 0.5 (n_D(0)#tau#_ET_i(0) - 4x10"2"0 m"-"3#centre dot#keV#centre dot#s) for 0.8 s and 2) full non-inductive current drive with 80% of the bootstrap current fraction. Physics of the internal transport barriers (ITBs) in RS plasmas, including the energy transport and the formation of ITB, were extensively studied. A nearly full current drive (92% non-inductively) was obtained with negative ion based neutral beam (NNB) injection (360 keV, 3.4 MW) in a high #beta#_p H-mode plasma (I_p=1.5 MA, B_T=3.7 T, q_9_5=4.2) with high plasma performance (#beta#_N=2.4 and H_8_9=2.56). Rise in the central electron temperature (T_e - 9 keV) resulted in the current drive efficiency #eta#_C_D of NNB reached 1.3x10"1"9 A/W/m"2, the highest for the neutral beam current drive. As for the H-mode plasmas, decrease in the ...

1994-06-01

261

Effective atomic numbers and electron densities of some biologically important compounds containing H, C, N and O in the energy range 145-1330 keV  

International Nuclear Information System (INIS)

A semi-empirical relation which can be used to determine the total attenuation cross sections of samples containing H, C, N and O in the energy range 145-1332 keV has been derived based on the total attenuation cross sections of several sugars, amino acids and fatty acids. The cross sections have been measured by performing transmission experiments in a narrow beam good geometry set-up by employing a high-resolution hyperpure germanium detector at seven energies of biological importance such as 145.4 keV, 279.2 keV, 514 keV, 661.6 keV, 1115.5 keV, 1173.2 keV and 1332.1 keV. The semi-empirical relation can reproduce the experimental values within 1-2%. The total attenuation cross sections of five elements carbon, aluminium, titanium, copper and zirconium measured in the same experimental set-up at the energies mentioned ...

2006-09-28

262

Radiation testing of organic ion exchange resins  

International Nuclear Information System (INIS)

A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of "1"3"7Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the ...

1983-04-11

263

Radiation testing of organic ion exchange resins  

Energy Technology Data Exchange (ETDEWEB)

A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of {sup 137}Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the ...

1995-09-01

264

Survey of naturally radioactive level of some new type wall materials  

International Nuclear Information System (INIS)

Naturally occurring radioactive materials (NORM) in seven new type wall materials were surveyed. The radioactivity was determined with HPGe-#gamma# spectrometer. The red mud has the highest radioactivity concentration, followed by slag building blocks, fly-ash building blocks (bricks), gangue bricks and light weight board materials, gypsum blocks. Fly-ash and slag contain higher NORM, which contributes the major part of the radioactivity in new wall materials. (authors)

2006-09-01

265

Natural radioactivity of rocks of productive strata of marine deposits in Azerbaijan  

Energy Technology Data Exchange (ETDEWEB)

Natural radioactivity of rocks is studied on the basis of core samples and radioactivity logs of marine deposits in Azerbaijan. Investigations have established mainly thorium-potassium nature of radioactivity. Data obtained are useful for identificafion of clay among other rocks, for determination of clayiness, and in presence of a corresponding relation - for determination of porosity according to the clayiness. It is shown that the clayiness may be determined from radioactive logs.

1981-01-01

266

Natural radioactivity  

International Nuclear Information System (INIS)

This chapter discusses the types of natural radioactive materials in the environment that include primordial natural radioactive materials such as K-40, U and Th, and daughters of their decay series. The discussion also includes secondary natural radioactive material generated through cosmic radiation interaction with nucleus of materials in the atmosphere. The dispersion of these radioactive materials to environment will also be part of the discussion. (Author)

267

Traces of evidence. Nuclear forensics and illicit trafficking  

International Nuclear Information System (INIS)

An IAEA databank lists a number of reported cases of illicitly trafficked nuclear or other radioactive materials. Apart from the traditional concern with nuclear proliferation, the post September 11th public is now wary of a possible attack by terrorists with a nuclear or radiation dispersion device (RDD). Until now, the seized quantities have not been sufficient to manufacture a nuclear explosive device, but they might be enough to construct an RDD. Recognizing the latent global challenge to public health and safety, the G8 States (Japan, USA, Germany, France, UK, Italy, Canada, and Russia) have called for 'joint international efforts to identify and suppress illicit supply' of, and demand for, nuclear material and to deter potential traffickers. One measure gaining in significance is to identify seized material and trace it back to its origin the objective of an emerging science known as nuclear forensics. Repeatedly nuclear or other ...

2003-06-01

268

Review of the microscopic cross sections for the americium isotopes in the resolved resonance region. [0. 5 eV to 10 keV  

Science.gov (United States)

The differential cross section measurements for /sup 241/Am, /sup 242m/Am and /sup 243/Am are reviewed in the energy range from 0.5 eV to 10 keV. Parameters extracted from resonance analysis, such as the neutron strength function, the average level spacing, the average capture and fission widths, are compared for the various measurements. The average capture and fission cross sections from 100 eV to 10 keV are directly compared. The status of the data set is discussed with suggestions for further measurements. 24 references.

1978-11-16

269

The Canonical Seyfert Spectrum: The Implications of OSSE ...  

Science.gov (United States)

... In a HEAO 1 study of active galaxies, principally Seyfert 1s, in the 2, 165 keV energy range, Rothschild et al. ... As discussed by Rothschild et al. ...

2011-05-14

270

On penetration effect in M1 component of 70.45 keV #gamma#-transition in "1"7"7Ta  

International Nuclear Information System (INIS)

... gamma radiation l conversion m conversion mev range 10-100 mixing ratio

1987-04-14

271

Electric and magnetic dipole transitions in odd-proton rare-earth nuclei  

International Nuclear Information System (INIS)

... gamma cascades kev range 10-100 lifetime lutetium 171 lutetium 173 lutetium

1972-05-01

272

Si and Si/P implants in In{sub 0.5}Ga{sub 0.5}P and In{sub 0.5}Al{sub 0.5}P  

Science.gov (United States)

Si and Si/P ion implantation doping of In{sub 0.5}Ga{sub 0.5}P and In{sub 0.5}Al{sub 0.5}P has been studied for several Si and P doses at energies of 90 and 100 keV, respectively. For single Si implants in InGaP a maximum Hall sheet electron concentration of 1.33{times}10{sup 13} cm{sup {minus}2} is achieved for a Si dose of 5{times}10{sup 13} cm{sup {minus}2}. When an optimum dose (2.5{times}10{sup 13} cm{sup {minus}2}) P coimplant is performed this electron concentration is increased by 65{percent}. The same dose Si implants in InAlP show a maximum effective activation of 3.9{percent} with no P coimplantation and 5.2{percent} with a P-implant dose 1.5 times the silicon dose. The apparent donor ionization energies are estimated from variable temperature Hall measurements to be 2{endash}5 meV for InGaP and {approximately}80 meV for InAlP. The deeper level in InAlP is attributed to the DX level found in the Al-containing material. The reduction ...

1996-06-01

273

On Boron Diffusion in MgF{sub 2}  

Science.gov (United States)

The MgF{sub 2} monocrystals were irradiated at room temperature with 390 keV B{sup +} ions up to the fluence of 10{sup 16} cm{sup -2}. The irradiated samples were (isochronally and isothermally) annealed in high vacuum at the temperatures 200 deg. C, 300 deg. C, 400 deg. C, 500 deg. C, 600 deg. C and 700 deg. C for the times ranging from 2-100 hours. After each annealing step, the boron depth distribution was determined using the neutron depth profiling technique. As implanted, the depth distributions of boron exhibited standard Gaussian-like forms, but the evaluated profile parameters, R{sub P} = 960 nm and {delta}R{sub P} = 140 nm, were higher than those calculated using the SRIM code (R{sub P} = 870 nm and {delta}R{sub P} = 115 nm). Annealing at temperatures up to 400 deg. C did not change the depth profiles. Annealing at 600 deg. C, however, led to a one-way gradual transfer of the boron atoms from the site of implantation towards the ...

2009-03-10

274

Initiation of ecton processes by interaction of a plasma with a microprotrusion on a metal surface  

International Nuclear Information System (INIS)

Evolution of rapid (?10 ns) Ohmic overheating of a microprotrusion on a surface in contact with a plasma by emission current is studied taking into account the energy carried by plasma ions and electrons, as well as Ohmic heating, emissive source of energy release (Nottingham effect), and heat removal due to heat conduction. Plasma parameters were considered in the range of n = 1014-1020 cm-3 and Te = 0.1 eV-10 keV. The threshold value of energy transferred to the surface from the plasma is found to be 200 MW/cm2; above this value, heating becomes explosive (namely, an increase in the temperature growth rate (?2T/?t2 > 0) and in passing current (?J/?t > 0) is observed in the final stage at T ? 104 K and j ? 108 A/cm2). In spite of the fact that Ohmic heating does not play any significant role for plasmas with a density lower than 10 18 cm-3 because the current is limited by the space charge of electrons, rapid overheating of top of ...

2008-12-01

275

Element distribution in the brain sections of rats measured by synchrotron radiation X-ray fluorescence  

International Nuclear Information System (INIS)

The concentration of trace elements in brain sections was measured by synchrotron radiation X-ray fluorescence. The relative concentration was calculated by means of the normalization of Compton scattering intensity approximately 22 keV, after the normalization for collecting time of X-ray spectrum and the counting of the ion chamber, and subtracting the contribution of the polycarbonate film for supporting sample. Furthermore, the statistical evaluation of the element distribution in various regions of the brain sections of the 20-day-old rats was tested. For investigating the distribution of elements in the brain of iodine deficient rats, Wistar rats were fed with iodine deficient diet and deionized water (ID group). The rats were fed the same iodine deficient diet, but drank KIO_3 solution as control (CT group). The results showed that the contents of calcium (Ca) in thalamus (TH) and copper (Cu) and iron (Fe) in cerebral cortex (CX) of ID ...

2004-02-27

276

An overview of the development of the first wall and other principal components of a laser fusion power plant  

International Nuclear Information System (INIS)

This paper introduces the JNM Special Issue on the development of a first wall for the reaction chamber in a laser fusion power plant. In this approach to fusion energy a spherical target is injected into a large chamber and heated to fusion burn by an array of lasers. The target emissions are absorbed by the wall and encapsulating blanket, and the resulting heat converted into electricity. The bulk of the energy deposited in the first wall is in the form of X-rays (1.0-100 keV) and ions (0.1-4 MeV). In order to have a practical power plant, the first wall must be resistant to these emissions and suffer virtually no erosion on each shot. A wall candidate based on tungsten armor bonded to a low activation ferritic steel substrate has been chosen as the initial system to be studied. The choice was based on the vast experience with these materials in a nuclear environment and the ability to address most of the key remaining issues with existing ...

2005-12-15

277
278

Method and apparatus for efficient photodetachment and purification of negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

Methods and apparatus are described for efficient photodetachment and purification of negative ion beams. A method of purifying an ion beam includes: inputting the ion beam into a gas-filled multipole ion guide, the ion beam including a plurality of ions; increasing a laser-ion interaction time by collisional cooling the plurality of ions using the gas-filled multipole ion guide, the plurality of ions including at least one contaminant; and suppressing the at least one contaminant by selectively removing the at least one contaminant from the ion beam by electron photodetaching at least a portion of the at least one contaminant using a laser beam.

2008-02-26

279

Inelastic collisions of molecular ions in the injected ion drift tube  

International Nuclear Information System (INIS)

... energy spectra inelastic scattering ion-molecule collisions mass spectrometers

1977-07-27

280

The concentration of natural radioactive materials in building materials  

International Nuclear Information System (INIS)

A survey is given on the results in hand on the natural radioactivity of building materials. It is shown that only a small percentage of building materials has an increased content of radioactive materials. The results are compared with approximate values given in a Russian publication. (orig./AK).

1974-09-23

285

X-ray micro-spectroscopy: a tool for micro-scale radionuclide speciation in heterogeneous nuclear waste repository materials  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: Large-scale problems such as nuclear waste disposal are increasingly recognized to be interconnected to small scale-mechanisms. Thus, synchrotron-based high-resolution analytical X-ray probes become important tools for exploring the micro-scale chemical reactivity of heterogeneous barrier materials used in nuclear waste repositories. In this study the layout of the micro-XAS beamline at the Swiss Light Source (SLS) will be presented. The beamline is optimized towards micro beam experiments ({approx}1 x 1 {mu}m{sup 2}) in the hard-X-ray regime (4 - {approx}22 keV) and allows to combine micro X-ray fluorescence (micro-XRF), micro X-ray absorption spectroscopy (micro- XAS), and micro X-ray diffraction (micro-XRD) investigations with radioactive samples. Furthermore, the potential of micro-XRF/XAS/XRD for acquiring spatially resolved molecular level information on the speciation and structural coordination ...

2005-07-01

286

Preliminary study of the {alpha} ratio measurement, ratio of the neutron capture cross section to the fission one for {sup 233}U, on the PEREN platform. Development and study of the experimental setup; Etude preliminaire de la mesure du rapport {alpha}, rapport de la section efficace moyenne de capture sur celle de fission de l'{sup 233}U, sur la plateforme PEREN. Developpement et etude du dispositif experimental  

Energy Technology Data Exchange (ETDEWEB)

Producing nuclear energy in order to reduce anthropic CO{sub 2} emission and to meet high energy demand, implies three conditions to the nuclear plants of the IV. generation: safety improvements, radioactive waste minimization, and fuel breeding for a sustainable use of the resources. The Thorium fuel cycle used in Molten Salt Reactors seems promising. Many numerical studies based on probabilistic codes are carried out in order to analyse the behaviour of such reactors. Nevertheless, one of the most important parameters is badly known: the alpha ratio of {sup 233}U, ratio of the neutron capture cross section to fission one for {sup 233}U. This key-parameter is necessary to calculate the breeding ratio and thus, the deployment capacities of those reactors. This Ph-D thesis was intended to prepare a precise measurement of the alpha ratio of {sup 233}U between 1 eV and 10 keV. Preliminary measurements have been performed on the experimental ...

2007-12-15

287

Selective adsorption of uranium on activated charcoal from electrolytic aqueous solutions  

Energy Technology Data Exchange (ETDEWEB)

Adsorption of uranium onto various solids is important from purification, environmental, and radioactive waste disposal points of view. Adsorption of uranium on activated charcoal has been studied as a function of shaking time, amount of adsorbent, pH, concentration of adsorbate, and temperature. Uranium adsorption obeys the Langmuir isotherm. {Delta}H{degrees} and {Delta}S{degrees} were calculated from the slope and intercept of plots ln K{sub D} vs 1/T. The influence of different anions and cations on uranium adsorption has been examined. The adsorption of other metal ions on activated charcoal has been studied under specified conditions to check its selectivity; consequently, uranium was removed from Cs, Ba, Zn, and Co. More than 98% adsorbed uranium on activated charcoal can be recovered with 65 ml of 3 M HNO{sub 3} solution. A wavelength dispersive x-ray fluorescence spectrometer was used for measuring uranium concentration.

1992-02-01

288

Propagation of an alkaline wave with a short contact time through an argilite sample from the Meuse-Haute Marne underground laboratory; Propagation d'une onde alcaline a temps de contact court a travers un echantillon d'argilite de l'est  

Energy Technology Data Exchange (ETDEWEB)

In the framework of the feasibility study of radioactive waste disposal in deep geologic formations, a clay formation (named 'argilite de l'Est') has been selected in the Meuse-Haute Marne region (France) for the construction of an underground laboratory. The percolation of alkaline solutions through the argilite has been studied using column experiments with short residence times (30 min). These experiments simulate the leaching of a cement which could be used in the building materials of the laboratory. The alkaline solutions used are mono-cationic solutions of calcium, sodium and strontium. The behaviour of calcium is differentiated from the other cations. For all alkaline solutions (NaOH, Ca(OH){sub 2} or Sr(OH){sub 2}) chemical reactions consuming both hydroxide ions and their associated cations have been evidenced. These reactions are heterogenous reactions of surface adsorption by site ionization. The calcium ...

2001-07-01

289

Programmed improvements of the alternating gradient synchrotron complex at Brookhaven National Laboratory, Upton, New York. Environmental assessment  

Energy Technology Data Exchange (ETDEWEB)

The purpose and need for DOE to undertake the actions described in this document are to improve the efficiency of the Alternating Gradient Synchrotron (AGS) complex. Benefits would include optimization of the AGS scientific program, increased high-energy and nuclear physics experimentation, improved health and safety conditions for workers and users, reduced impact on the environment and the general public, energy conservation, decreased generation of hazardous and radioactive wastes, and completion of actions required to permit the AGS to be the injector to the Relativistic Heavy Ion Collider (RHIC)., Improved efficiency is defined as increasing the AGS`s capabilities to capture and accelerate the proton intensity transferred to the AGS from the AGS booster. Improved capture of beam intensity would reduce the beam losses which equate to lost scientific opportunity for study and increased potential for radiation doses to workers and the general ...

1994-03-01

290

Endogenous biosynthesis of arachidonic acid epoxides in humans: Increased formation in pregnancy-induced hypertension  

Energy Technology Data Exchange (ETDEWEB)

Arachidonic acid is metabolized by means of P450 isoenzyme(s) to form epoxyeicosatrienoic acids (EETs) and their corresponding dihydroxy derivatives (DHETs). In the present study, we established the presence in human urine of 8,9-, 11,12-, and 14,15-EETs and their corresponding DHETs by developing quantitative assays and using negative ion, chemical ionization GC/MS and octadeuterated internal standards. Urinary excretion of 8,9- and 11,12-DHET increased in healthy pregnant women compared with nonpregnant female volunteers. By contrast, excretion of 11,12-DHET and 14,15-DHET, but not the 8,9-DHET regioisomer, increased even further in patients with pregnancy-induced hypertension. Intravenous administration of (3H)14,15-EET to three dogs markedly increased its DHET in plasma. The terminal half-life ranged from 7.9-12.3 min and the volume of distribution (3.5-5.3 liters) suggested limited distribution outside the plasma compartment. Negligible ...

1990-08-01

291

An aerial radiological survey of the Portsmouth Gaseous Diffusion Plant and surrounding area  

International Nuclear Information System (INIS)

An aerial radiological survey was conducted from August 10-16, 1993, over a 78-square-kilometer (30-square-mile) area of the Portsmouth Gaseous Diffusion Plant and surrounding area located near Portsmouth, Ohio. The survey was performed at a nominal altitude of 46 meters (150 feet) with a line spacing of 76 meters (250 feet). A contour map of the terrestrial gamma exposure rate extrapolated to 1 meter above ground level was prepared and overlaid on a set of United States Geological Survey topographic maps of the area and an aerial photograph of the plant. The terrestrial gamma exposure rates varied from about 7 to 14 microroentgens per hour at 1 meter above the ground. Protactinium-234m was observed at six sites within the boundaries of the plant. At a seventh site, only uranium-235 was observed. No other man-made, gamma ray-emitting radioactive material was present in a detectable quantity, either on or off the plant property. Soil sample and pressurized ...

2005-05-01

292

Actinide, strontium, and cesium removal from Hanford radioactive tank sludge  

International Nuclear Information System (INIS)

A pretreatment flowsheet was tested for separating key radionuclide components from the sludge stored in one of the high level waste tanks (B-110) at the Hanford Site; this sludge resulted primarily from the bismuth phosphate process, which was one of the three major plutonium separation processes used at Handford. This test involved (1) washing with water, (2) caustic leaching, (3) acid dissolution, (4) separation of transuranic elements (TRUs) by extraction with octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide(CMPO), (5) separation of Sr by extraction with di-t-butylcyclohexano-18-crown-6, (6) separation of Cs from the acid-dissolved sludge solution by treatment with ammonium molybdophosphate (AMP), and (7) separation of Cs from the sludge wash and caustic leach solutions by ion exchange using a phenol-formaldehyde resin (CS-100). The results of the radionuclide separation steps indicated that the proposed flowsheet is a viable approach to pretreating ...

293

Heavy ion induced changes in nuclear waste glasses: a micro Raman investigation  

International Nuclear Information System (INIS)

Borosilicate based glass formulations have been found suitable for fixing the HLW (high level radioactive liquid waste) generated after reprocessing of the spent nuclear fuel. As the glass experiences continuous irradiation by #alpha#, #beta#a, and #gamma# radiations from the radioactive components of HLW, alteration in the glass structure may occur. Understanding of these structural evolutions of the nuclear waste glasses under irradiation is crucial to secure long term disposal and predict their behavior. In the present work, alkali based barium borosilicate glasses, having composition similar to that of Trombay Research Reactor waste glass were irradiated with high energy "1"2C beam and the radiation induced changes were monitored by micro Raman experiment. Since a "1"2C atom can be considered as a cluster of alphas, this beam was chosen to yield linear energy losses (LET) comparable to that in case of a particles. The irradiations were ...

2010-12-01

294

Characterization and Source Term Assessments of Radioactive Particles from Marshall Islands Using Non-Destructive Analytical Techniques  

Energy Technology Data Exchange (ETDEWEB)

A considerable fraction of radioactivity entering the environment from different nuclear events is associated with particles. The impact of these events can only be fully assessed where there is some knowledge about the mobility of particle bound radionuclides entering the environment. The behavior of particulate radionuclides is dependent on several factors, including the physical, chemical and redox state of the environment, the characteristics of the particles (e.g., the chemical composition, crystallinity and particle size) and on the oxidative state of radionuclides contained in the particles. Six plutonium-containing particles stemming from Runit Island soil (Marshall Islands) were characterized using non-destructive analytical and microanalytical methods. By determining the activity of {sup 239,240}Pu and {sup 241}Am isotopes from their gamma peaks structural information related to Pu matrix was obtained, and the source term was revealed. Composition and ...

2005-06-11

295

Evaluation of induced radioactivity in 10 MeV-electron irradiated spices, (1)  

International Nuclear Information System (INIS)

Black pepper, white pepper, red pepper, ginger and turmeric were irradiated with 10 MeV electrons from a linear accelerator to a dose of 100 kGy and radioactivity was measured in order to estimate induced radioactivity in the irradiated foods. Induced radioactivity could not be detected significantly by #gamma#-ray spectrometry in the irradiated samples except for spiked samples which contain some photonuclear target nuclides in the list of photonuclear reactions which could produce radioactivity below 10 MeV. From the amount of observed radioactivities of short-lived photonuclear products in the spiked samples and calculation of H_5_0 according to ICRP Publication 30, it was concluded that the induced radioactivity and its biological effects in the 10 MeV electron-irradiated natural samples were negligible in comparison with natural ...

296

Penetration effect in the M1 component of "1"7"7Ta #gamma#-transition with energy of 70.45 keV  

International Nuclear Information System (INIS)

The magnetic #beta#-spectrometer of the #pi# #sq root#2 type with 0.07% pulse resolution is used to measure the intensities of interval conversion electrons on L- and M-subshells of 70.45 keV "1"7"7 Ta gamma-transition. The results are analyzed and the values of mixing parameter #sigma#(E2/M1) and penetration parameter #lambda# are obtained.

297

Gamma-ray spectra from neutron capture on /sup 87/Sr  

Energy Technology Data Exchange (ETDEWEB)

The gamma-ray spectrum following neutron capture on /sup 87/Sr was measured at 3 neutron energies: E/sub n/ = thermal, 2 keV, and 24 keV. Gamma rays were detected in a three-crystal Ge(Li)-NaI-NaI pair spectrometer. Gamma-ray intensities deduced from these spectra by spectral unfolding are presented.

1981-07-01

298

Evaluation of adhesive plasters by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

A radiometric method was elaborated for surface density determinations of the adhesive layer of plasters by radionuclide X-ray fluorescence using the 17.47 keV bremsstrahlung of "1"4"7Pm/Mo. The bremsstrahlung line excites the 8.63 keV characteristic K#alpha# line of Zn contained in the adhesive layer of the plaster as a filling material in the form of ZnO. In homogeneous adhesive layers the Zn content is proportional to surface density. (author).

1976-01-01

299

Observed energy dependence of Fano factor in silicon at hard X-ray energies  

Energy Technology Data Exchange (ETDEWEB)

An experimental evaluation of the Fano factor F in silicon at hard X-ray energies (5.9-136.5 keV) has been performed by means of a low-noise, high charge collection efficiency silicon drift detector with on-chip electronics. A dependence of F from the detector temperature as well as from the energy of the X-ray photons has been found. Assuming a pair creation energy equal to 3.64 eV, at +20 deg. C the F factor was observed to vary from 0.124{+-}0.006 at 5.9 keV up to 0.159{+-}0.002 at 122 keV. At -35 deg. C, the change of F with respect to the photon energy was less remarkable but nevertheless statistically significant, from 0.123{+-}0.002 at 5.9 keV up to 0.134{+-}0.001 at 122 keV. To our knowledge, the present results represent the first experimental evidence of an energy dependence of the Fano factor in silicon at hard X-ray energies.

1999-03-01

300

High resolution alpha-particle spectroscopy using CR-39 plastic track detector  

Energy Technology Data Exchange (ETDEWEB)

A technique has been developed for high resolution alpha particle spectroscopy from track length determination in CR-39 plastic. On individual tracks an energy resolution deltaE close to the range straggling limit is obtainable. For 6 MeV alpha-particle deltaE is proportional 35 keV on individual particles and for groups of particles deltaE proportional 20 keV can be achieved using certain data selection criteria. At 100 keV on individual particles deltaE is proportional 20 keV. The analysis requires 1) a knowledge of the track-etch rate (Vsub(T))-range relationship and 2) a theoretical understanding of alpha-particle track structure in CR-39 as a function of particle energy, dip angle and degree of etching. The structure of alpha-particle etched tracks in CR-39 is described and two methods of analysis discussed. Examples are given of the resolution attainable on tracks of alpha-particles as natural ...

1984-06-15

301

Conceptual Design of Superconducting Quadrupole Arrays for the Heavy-Ion Fusion  

CERN Document Server

Conceptual Design of Superconducting Quadrupole Arrays for the Heavy-Ion Fusion

1999-01-01

302

Compact Proton and Carbon Ion Synchrotrons for Radiation Therapy  

CERN Document Server

Compact Proton and Carbon Ion Synchrotrons for Radiation Therapy

2002-01-01

303

Electrodeless, multi-megawatt reactor for room-temperature, lithium-6/deuterium nuclear reactions  

International Nuclear Information System (INIS)

This paper describes a reactor design to facilitate a room-temperature nuclear fusion/fission reaction to generate heat without generating unwanted neutrons, gamma rays, tritium, or other radioactive products. The room-temperature fusion/fission reaction involves the sequential triggering of billions of single-molecule, "6LiD 'fusion energy pellets' distributed in lattices of a palladium ion accumulator that also acts as a catalyst to produce the molecules of "6LiD from a solution comprising D_2O, "6LiOD with D_2 gas bubbling through it. The D_2 gas is the source of the negative deuterium ions in the "6LiD molecules. The next step is to trigger a first nuclear fusion/fission reaction of some of the "6LiD molecules, according to the well-known nuclear reaction: "6Li + D #-># 2"4He + 22.4 MeV. The highly energetic alpha particles ("4He nuclei) generated by this nuclear reaction within the palladium will cause shock and ...

304

Development of low-level liquid-waste treatment systems: April-September 1982  

Energy Technology Data Exchange (ETDEWEB)

A preliminary investigation was conducted on ion specific membranes. This investigation concentrated on testing candidate organic compounds for transporting cesium ions through a membrane composed of the organic compound supported on a substrate. Solid PVC membranes were initially tried, but were found to be too slow. Thereafter, only liquid membranes were tested. These were faster and cesium concentration factors up to 2.96 were achieved in a single membrane cell. A cell with two membranes achieved a cesium concentration factor of 4.19. Cesium precipitation with sodium tetraphenyl borate in high sodium concentrations was explored. No interference from sodium was found until the sodium nitrite concentration reached 4.5 moles. Concurrently, cesium concentrations as high as 5.4 g/L were precipitated. Potassium tetraphenyl borate is being investigated for use in exchange columns for the removal of cesium from solutions. Initial investigations show ...

1982-12-22

305

Development of low-level liquid-waste treatment systems: April-September 1982  

International Nuclear Information System (INIS)

A preliminary investigation was conducted on ion specific membranes. This investigation concentrated on testing candidate organic compounds for transporting cesium ions through a membrane composed of the organic compound supported on a substrate. Solid PVC membranes were initially tried, but were found to be too slow. Thereafter, only liquid membranes were tested. These were faster and cesium concentration factors up to 2.96 were achieved in a single membrane cell. A cell with two membranes achieved a cesium concentration factor of 4.19. Cesium precipitation with sodium tetraphenyl borate in high sodium concentrations was explored. No interference from sodium was found until the sodium nitrite concentration reached 4.5 moles. Concurrently, cesium concentrations as high as 5.4 g/L were precipitated. Potassium tetraphenyl borate is being investigated for use in exchange columns for the removal of cesium from solutions. Initial investigations show ...

306

The possible impact of atmospheric radioactive discharges from UK nuclear installations on acid deposition  

International Nuclear Information System (INIS)

The effect of atmospheric radioactive emissions from United Kingdom nuclear installations on acid deposition is assessed. Nitrogen oxide and ozone production resulting from and associated with discharges of airborne radioactivity, comparison with conventional emissions, and the direct effects of radioactive emissions on trees, are all discussed. (UK).

307

Radioactive source management in Daya Bay NPP  

International Nuclear Information System (INIS)

'Small radioactive source results in big accident' have occurred repeatedly in China and worldwide alike. Radioactive source management is one of the key activities for a nuclear power plant to maintain its good safety record and image to the public. From aspects of establishing the management system, centralized storage, periodic accounting, performing whole process control to the source usage and experience feedback etc., the author reports the practice and experience of radioactive source management in Daya Bay Nuclear Power Plant

1999-11-01

308

Radioactive and mixed waste management plan for the Lawrence Berkeley Laboratory Hazardous Waste Handling Facility  

Energy Technology Data Exchange (ETDEWEB)

This Radioactive and Mixed Waste Management Plan for the Hazardous Waste Handling Facility at Lawrence Berkeley Laboratory is written to meet the requirements for an annual report of radioactive and mixed waste management activities outlined in DOE Order 5820.2A. Radioactive and mixed waste management activities during FY 1994 listed here include principal regulatory and environmental issues and the degree to which planned activities were accomplished.

1995-01-01

309

Natural radioactive materials occurrence in oil facilities  

International Nuclear Information System (INIS)

This work presents and describes the natural radioactive occurrence in oil facilities. The origins of the detected radioactivity and the reasons of its settlement are discussed. The measurements results carried out in oil facilities in the Neuquina basin (Argentine) are shown in this work. The aim is to describe the actual situation and to evaluate the magnitude of the problem. Finally, recommendations are proposed to protect the health of the workers, especially of those who carry out the cleaning of the equipment, and to guarantee an appropriate final disposal for the generated radioactive residuals. (author)

2001-06-01

310

Minimally Invasive Endoscopic Pituitary Surgery  

Medline Plus

... There has been a role for placement of yttrium or radioactive phosphorous in a tumor called craniopharyngioma, ...

312

Estimation of the age of the universe by the nucleochronology method  

Energy Technology Data Exchange (ETDEWEB)

Unconditional estimates are suggested for the age of radioactive nuclei and hence for the age of the Universe.

1983-10-01

313

Content of long-lived radionuclides in the moss cover of the eastern-Ural radioactive trace region  

Energy Technology Data Exchange (ETDEWEB)

This study examines the extent of radioactive pollution of moss cover of forest communities of the Kamenskii district of the Sverdlovsk region. This area contains the periphery section of the Eastern-Ural Radioactive Trace, formed as a result of the Kyshtymskii accident. Mosses do not release radionuclides for a long time, making them a biological indicator of radioactive environmental pollution and making them useful for radioecological monitoring. 14 refs., 2 figs., 1 tab.

1995-07-01

315

Measurement and analysis of neutron production cross sections and determination of some reaction rates for nuclear astrophysical calculations  

International Nuclear Information System (INIS)

The absolute cross sections of "2"3Na(p,n)"2"3Mg, "2"7Al(p,n)"2"7Si and "3"0Si(#alpha#,n)"3"3S reactions were measured in the incident energy range of 5.05 to 5.80, 5.80 to 6.25 and 3.975 to 6.235 MeV respectively using a spherically shaped 4#pi# neutron detector. In the energy range 5.80 to 7.80 and 6.235 to 11.30 MeV the absolute cross sections of "2"3Na(p,n)"2"3Mg and "3"0Si-(#alpha#,n)"3"3S reactions were determined by optical model calculations. The cross sections of the inverse reactions "2"3Mg(n,p)"2"3Na and "3"3S(n,#alpha#)"3"0Si were also calculated by the same method for the neutron energy range of 10 keV to 7.50 MeV for each reaction. The cross section of the latter reaction in the neutron energy range of 10 keV to 840 keV was also determined from its inverse reaction "3"0Si(#alpha#,n)"3"3S by the application of the detailed balance theorem. The reactions for which the cross sections were determined are of ...

316

DECAY OF Ta$sup 177$ AND Lu$sup 177$ TO LEVELS IN Hf$sup 17$$sup 7$  

Science.gov (United States)

The decays of Ta/sup 177/ and Lu/sup 177/ to levels in vestigated with beta spectrometers, NaI(Tl) gamma spectrometers, and fast coincidence and angular correlation techniques. Energy levels in Hf/sup 177/ were characterized according to their energy (kev), the Nilsson asymptotic quantum numbers (Nn/sub 2/ LAMBDA ), the total angular momentum and its component along the symmetry axis (I,K), and the parity ( pi ) as follows: 0STA5I4 7/2, 7/2-!; 112.97STA514 9/2, 7/ 2-!; 249.7STA5I4 11/2, 7/1-!; 32l.34STA624 9/2, 9/2+1; 447.9STA624 11/2, 585.8STA642 7/2, 3/2+1; 509.0STA5I2 5/2, 5/1-1; 605.5STA512 7/2, 5/2-!; 746.04STA633 7/2, 7/2+1; 848.2STA 633 9/2, 7/2+1; and 1058.38STA503 7/2, 7/2-!. The levels at 447.9, 488.8, and 585.8 kev are tentative. The spins and parities were uniquely determined by angular correlation and internal conversion data for the levels at 746.0 and 848.2 kev, asof the levels at 0, ...

1961-10-15

317

Reduced boron diffusion under interstitial injection in fluorine implanted silicon  

International Nuclear Information System (INIS)

Point defect injection studies are performed to investigate how fluorine implantation influences the diffusion of boron marker layers in both the vacancy-rich and interstitial-rich regions of the fluorine damage profile. A 185 keV, 2.3x10"1"5 cm"-"2 F"+ implant is made into silicon samples containing multiple boron marker layers and rapid thermal annealing is performed at 1000 deg. C for times of 15-120 s. The boron and fluorine profiles are characterized by secondary ion mass spectroscopy and the defect structures by transmission electron microscopy (TEM). Fluorine implanted samples surprisingly show less boron diffusion under interstitial injection than those under inert anneal. This effect is particularly noticeable for boron marker layers located in the interstitial-rich region of the fluorine damage profile and for short anneal times (15 s). TEM images show a band of dislocation loops around the range of the fluorine implant and the ...

2007-12-01

318

Direct Comparison of the X-Ray Emission and Absorption of Cerium Oxide  

Energy Technology Data Exchange (ETDEWEB)

Bremstrahlung Isochromat Spectroscopy (BIS). The XES spectra were collected using a Specs electron gun for the excitation and the XES 350 grating monochromator and channel plate system from Scienta as the photon detection. Spectra were collected in 'normal mode,' where the electron gun kinetic energy (KE) and the energy position of the center of the channel plate were both fixed and the energy distribution in the photon (hv) spectrum was derived from the intensities distributed across the channel plate detector in the energy dispersal direction. The polycrystalline Ce sample was oxidized by exposure to air at ambient pressures. After introduction to the ultra-high vacuum system, the oxidized sample was bombarded with Ar, to clean the topmost surface region and stabilize the surface and near surface regions. Although CeO{sub 2} would be the thermodynamically preferred composition in an oxygen rich environment, the combination of a vacuum environment and ...

2010-11-24

319

Measurement of oxidation rate of sulfite in rain water in Yokohama, Japan  

Energy Technology Data Exchange (ETDEWEB)

In recent years, the influences of acid rain such as the acidification of lake water, on bio-system by the heavy metals from effluent of soils with acid rain and also on the structural materials of buildings are seriously discussed. Sulfur and nitrogen that are contained in fossil fuels are released into the atmosphere by the fuel combustion as their oxides dissolve in rain drops as sulfite and nitrous ions, where they are further oxidized into sulfate and nitrate ions These ions lower the pH of rain water resulting so-called acid rain. Therefore, it is important to accurately determine these ions in rain water for the investigation of reality of acid rain. However, it is not easy to accurately determine these ions, especially for sulfite ions in rain water, since they are quickly oxidized by the catalytic action of metallic ions such as ...

1986-04-01

320

The physics of Electron Beam Ion Sources  

Energy Technology Data Exchange (ETDEWEB)

There are 13 Electron Beam Ion Sources in operation which produce highly charged ions, up to Th[sup 80+] and Xe[sup 53+]. Most of the sources are used to study these ions under electron impact or when recombining with gaseous or solid targets. That provides an insight into the atomic physics of these highly charged ions and into the physics of the plasma in which such ions can be found. This paper reviews the present knowledge of atomic processes, important in the production of such ions with an EBIS.

1990-01-01

321

The physics of Electron Beam Ion Sources  

Energy Technology Data Exchange (ETDEWEB)

There are 13 Electron Beam Ion Sources in operation which produce highly charged ions, up to Th{sup 80+} and Xe{sup 53+}. Most of the sources are used to study these ions under electron impact or when recombining with gaseous or solid targets. That provides an insight into the atomic physics of these highly charged ions and into the physics of the plasma in which such ions can be found. This paper reviews the present knowledge of atomic processes, important in the production of such ions with an EBIS.

1990-12-31

322

RXTE observations of Cas A  

International Nuclear Information System (INIS)

Rossi X-ray Timing Explorer (RXTE) observations of the bright supernova remnant Cas A have revealed a hard power law component above 10 keV in addition to two thermal components inferred from ASCA measurements of the many line centroids from low-Z elements. The power law can be shown to be consistent with synchrotron emission from radio to hard x-rays by electrons of up to 4 x 10"1"3 eV. Measurement of the 1157 keV line by CGRO from "4"4Sc in the chain of decay of "4"4Ti predicts that the two "4"4Ti lines at 68 and 78 keV should appear at the CGRO intensity. RXTE has placed upper limits on such lines that are marginally consistent with the CGRO measurement. Implications of these results on sites for cosmic ray acceleration and nucleosynthesis are discussed.

1999-01-01

323

Measurement of attenuation coefficients for bone, muscle, fat and water at 140, 364 and 662keV ?-ray energies  

International Nuclear Information System (INIS)

The half-value thicknesses, linear and mass attenuation coefficients of biological samples such as bone, muscle, fat and water have been measured at 140, 364 and 662keV ?-ray energies by using the ATOMLABTM-930 medical spectrometer. The ?-rays were obtained from 99mTc, 131I and 137Cs ?-ray point sources. Also theoretical calculations have been performed in order to obtain the half-value thicknesses and, mass and linear attenuation coefficients at photon energies 0.001keV-20MeV for bone, muscle and water samples. The calculated value and the experimental results of this work and the other results in literature are found to be in good agreement.

2006-11-01

324

Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr  

Energy Technology Data Exchange (ETDEWEB)

Neutron capture ..gamma..-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.

1985-01-15

325

Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr  

International Nuclear Information System (INIS)

Neutron capture #gamma#-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.

1984-09-10

326

Formation of charge and energy distribution of heavy ions in substance according to diffusion model  

International Nuclear Information System (INIS)

The formation of the ions charge and energy distributions of the ions slowed down or randomly changing their charge in the collisions with the medium particles are studied. The effect of the ions dispersion by the charge on the Bragg curve form is investigated. The proposed diffusion approximation for the heavy ions kinetic equation makes it possible to determine simply the parameters of the ions distribution by charge and energy on the whole way of the ions motion. The relation between the ions charge distribution characteristics and the cross sections of the ionization-recombination processes is indicated. The ions distributions, calculated in the proposed analytical model, are compared with the results of the numerical calculations. Good agreement between the analytical, numerical and experimental results is obtained

2003-11-01

327

Ion Langmuir waves in a nonneutral plasma  

Energy Technology Data Exchange (ETDEWEB)

A nonneutral /sup 7/Li/sup +/ ion plasma is described in which ion Langmuir waves are observed for the first time. The properties of these waves near the Brillouin density limit are investigated.

1981-01-05

328

UK regulations for NORM [naturally occurring radioactive material  

International Nuclear Information System (INIS)

The primary UK legislation relating to the use of radioactive materials are the Radioactive Substances Act 1993 (RSA, 1993) and the Ionising Radiations Regulations 1999 (IRR, 1999). These implement the European Union's Basic Safety Standards Directive (EUBSS) (EC, 1996). The Radioactive Substances Act 1993 (RSA93) regulates the accumulation, storage and disposal of radioactive waste, principally to control potential doses to members of the public. The Ionising Radiations Regulations 1999 (IRR, 1999) deal primarily with regulating the doses that people receive at work. Both of these pieces of legislation apply to the use of materials containing naturally occurring radionuclides. Historically UK regulations relating to radioactive materials have covered both artificial and natural radionuclides

2002-09-23

329

Low-level Waste Forum meeting report. Winter meeting, January 26--28, 1994  

Energy Technology Data Exchange (ETDEWEB)

The Low-Level Radioactive Waste Forum is an association of representatives of states and compacts established to facilitate state and compact commission implementation of the Low-Level Radioactive Waste Policy Act of 1980 and the Low-Level Radioactive Waste Policy Amendments Act of 1985 and to promote the objectives of low-level radioactive waste regional compacts. The Forum provides an opportunity for states and compacts to share information with one another and to exchange views with officials of federal agencies. The Forum participants include representatives from regional compacts, designated host states, unaffiliated states, and states with currently-operating low-level radioactive waste facilities. This report contains information synthesizing the accomplishments of the Forum, as well as any new advances that have been made in the management of low-level ...

1994-12-31

330

Traditional Fusion reaction: D + T n (14.07 MeV) + 4He (3.52 MeV ...  

Science.gov (United States)

as for direct energy conversion in specialized direct electrical energy conversion plants. Figure 1. An energetic (~163KeV) proton and a 11boron nucleus fuse ...

331

The study of "1"0"1Mo decay  

International Nuclear Information System (INIS)

The decay of "1"0"1Mo to levels in "1"0"1Tc has been studied using the three-parameter (#gamma#-#gamma#-t) coincidence system of HpGe-HpGe detectors. According to the coincidence data, the decay scheme was modified. The positions of 221.80, 318.00, 377.90, 452.50, 515.42, 1011.05 and 1759.72 keV transitions have been arranged again, the transition positions of 104.70, 105.95 and 774.15 keV gamma-rays have been assigned for the first time, the positions of 169.00, 590.91, 980.52 and 1431.68 keV transitions have been reconfirmed, the 1508.01 keV gamma-ray was observed simultaneously for the first time and its transition position has been assigned. The #beta#-intensities and the values of log ft of most levels were calculated. (author)

2000-09-01

332

Studies on energy level schemes of some nuclei by Gamma-ray spectroscopy  

International Nuclear Information System (INIS)

several authors tried to drive codes to construct nuclear level scheme of nuclei using a set of measured gamma -ray transitions and known energy levels, Ritz combination principle proved to be useful in constructing a more complete decay scheme. In this thesis the energy level schemes of some nuclei have been investigated by the measurements of the gamma - ray energies and use of Ritz combination code. The nuclei under investigation are "110m Ag (253 d)"110 Cd and "166m Ho (1200 yr) "166 E r. On the basis of the suggested level at 2249.02 keV by the Ritz code new positions of the two gamma-ray transitions at 677.5 and 706.6 KeV are found in decay scheme of "110m Ag. Also by this code, new position for the 994.84 KeV gamma-ray transition were established to depopulate the level at 1075.2 KeV.

1984-01-01

333

Experimental research on passive #gamma# scanning system at hot-cell for hull monitoring  

International Nuclear Information System (INIS)

A simulated hull monitoring system based on passive #gamma# ray scanning was set-up in K-01 hot-cell, which consists of a simulated hull basket, a collimator system, a 150 cm"3 HPGe detector and an ORTEC-919 multichannel buffer-computer system. Six different kinds of experimental set-up were established to simulate the variations of #gamma# ray source term distribution (partly concentration) and the variations of matrix density (+46.1%). The experimental results show that the biases of peak area is better than -25.3% for "1"3"7Cs 662 keV #gamma# rays and -18.6% for "1"4"4Ce-"1"4"4Pr 2186 keV #gamma# rays. The hardness of pulse height spectrum is demonstrated to show that the peak area ratio of 2186 keV to 662 keV varies from 380 to 72 when the thickness of lead filter varies form 5 mm to 30 mm. Also studied are the design parameters of collimator system.

334

Electron Flux - 8.0 keV - ISWA wiki - ISWA - NASA  

Science.gov (United States)

Nov 14, 2009 ... Ring Current electrons from the Fok Ring Current Model are computed using plasma and magnetic field values from the SWMF magnetosphere ...

335

Electron Flux - 4.7 keV - ISWA wiki - NASA  

Science.gov (United States)

Nov 14, 2009 ... Ring Current electrons from the Fok Ring Current Model are computed using plasma and magnetic field values from the SWMF magnetosphere ...

336

Electron Flux - 179 keV - ISWA wiki - ISWA - NASA  

Science.gov (United States)

Nov 14, 2009 ... Ring Current electrons from the Fok Ring Current Model are computed using plasma and magnetic field values from the SWMF magnetosphere ...

337

Parity nonconservation in "2"0"7Pb  

International Nuclear Information System (INIS)

Two experiments are currently underway to measure the single-particle weak mixing matrix element for the 1064 KeV transition in "2"0"7Pb. One experiment measures the circular polarization of the 1064 KeV gamma ray emitted from an unpolarized source, while the other experiment measures the forward-backward asymmetry of gamma rays emitted from a polarized source. Analysis of the first set of polarized source data yields an upper limit of 46 eV for the single-particle weak mixing matrix element. copyright 1995 American Institute of Physics.

338

Measurement of M shell X-ray production cross sections and fluorescence yields for the elements in the atomic range 70#<=#Z#<=#92 at 5.96 keV  

International Nuclear Information System (INIS)

Total M X-ray cross sections for 12 elements in atomic range 70#<=#Z#<=#92 were measured at 5.96 keV Mn K X-ray photon energy. The average M shell fluorescence yields (anti #omega#_M) of these elements have also been observed using the presently measured cross section values and the theoretical M shell photoionisation cross section values. (orig.).

339

Investigation of the "1"0"1Mo level and gamma-decay scheme by thermal neutron capture in "1"0"0Mo  

International Nuclear Information System (INIS)

The #gamma#-radiation following thermal neutron capture in "1"0"0Mo has been studied by singles and coincidence measurements. A "1"0"1Mo level scheme has been deduced and is compared with the results of previous (d,p), (n,#gamma#) and "1"0"1Nb decay studies. The existence of the first excited state at 13.51 keV has been confirmed. The present data yield a neutron binding energy of 5398.4 KeV. (Auth.).

1975-03-01

340

Inelastic scattering of electrons by close-lying levels of isomeric nuclei  

Energy Technology Data Exchange (ETDEWEB)

The process of inelastic scattering of hot plasma electrons with energies upto 3 keV by a pair of close-lying nuclear levels (..delta../ital E/less than or equal to2keV), one of whichis isomeric, is discussed. The transition cross sections in the nuclei/sup 242/Am, /sup 171/Lu, and /sup 73/Se are calculated. Estimates of the numberof isomeric nuclei de-excited as a result of electron-stimulated processes in aplasma with parameters characteristic of present-day experiments in controlledthermonuclear fusion are given.

1988-11-01

345

Heavy-ion accelerators and predicted lifetimes of highly stripped ions  

International Nuclear Information System (INIS)

(Sep 1973). United Kingdom Sinanoglu, O. Luken, W. Yale Univ., New Haven,

1973-01-01

347

Use of solid state nuclear track detectors for radon concentration measurements indoors  

International Nuclear Information System (INIS)

An indoor radioactive survey is being conducted in an Italian district. Preliminary results identified a zone with significant radioactive levels, in which a new specific survey has been planned. In this paper attention is dedicated mainly to radon measurement technique and results.

348

Studies on Inhibition of Intestinal Absorption of Radioactive Strontium  

UK PubMed Central (United Kingdom)

A method is reported which permits selective suppression of absorption of radioactive strontium from ingested food material, permitting the calcium to be available to the body. Studies were carried...Full Text Available

1964-08-08

349

Radioactivity of Tobacco Leaves and Radiation Dose Induced from Smoking  

UK PubMed Central (United Kingdom)

The radioactivity in tobacco leaves collected from 15 different regions of Greece and before cigarette production was studied in order to find out any association between the root uptake of radionuclides...Full Text Available

2009-02-01

350

Radioactive Waste Disposal for Fission and Fusion Reactors.  

Science.gov (United States)

The calculated radioactive waste inventories of the Turkey Point pressurized water fission reactor (PWR) and the Starfire conceptual fusion tokamak are compared as a function of time from initial start-up to 10,000 years after decommissioning. Only materi...

1989-01-01

351

Naturally radioactive waste materials. Part 1. Assessment and monitoring of materials and residues  

International Nuclear Information System (INIS)

The amended Radiation Protection Ordinance of 2001 contains regulations on natural radioactive materials, whose recycling or disposal poses practical problems. There is little experience in this field so far.

2003-03-01

352

Laser Technology for Remote Treatment of Atomic Equipment  

International Science & Technology Center (ISTC)

Investigation of Interaction of Laser Radiation with Radioactive Deposits on the metal Surface and Creation of Experimental Stand for Development of Laser Technology for Remote Treatment of Materials Contaminated with Radioactive Substances at the Atomic Power Plants

353

Granite Countertops and Radiation | Radiation Protection | US EPA  

Wastenet

... Top of page Testing Radiation coming from granite countertops results from natural radioactive material in the granite. Identifying the presence and concentration of radioactive elements in granite requires expensive and sophisticated portable instruments or laboratory equipment. These instruments and equipment require proper calibration, and interpretation of ...

354

Thermal-physical analysis of low-radioactive thermonuclear plasma in the magnetic fusion device  

International Nuclear Information System (INIS)

... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,

2006-09-11

355

The use of Radioactive labeling in hemoglobin identification  

International Nuclear Information System (INIS)

The basic approach to radioactive labeling techniques in hemoglobin identification consists of mixing 14C labeled normal carrier globin with 3H labeled unknown globin and carrying out the subsequent separations and purifications looking at the distribution of 3H and 14C radioactivity. This technique was devised to ascertain the amino acid substitution in Hb Indianapolis and was instrumental in solving the structure of Hb Vicksburg. It was also useful in determining the purity of gamma-chains from cultures of human and baboon erythroid progenitors. Another use of this technique would be in identifying aberrant peaks of radioactivity in chain separation chromatograms, such as ''pre-peaks''.

357

Radioiodine benzodiazepines as brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a radioiodinated benzodiazepine derivative. It comprises a lower alkyl group with 1-4 C-atoms and a radioactive iodine.

1992-03-17

358

Radioiodine benzodiazepines as brain imaging agents  

International Nuclear Information System (INIS)

This patent describes a radioiodinated benzodiazepine derivative. It comprises a lower alkyl group with 1-4 C-atoms and a radioactive iodine.

1990-06-25

359

Radiation-stimulated diffusion of aerosols  

Energy Technology Data Exchange (ETDEWEB)

The diffusion coefficient of particles in radioactive gases has been calculated with account of random wandering of aerosols (occurrence of local fields affecting the particles; recoils accompanying radiation emitted by particles, etc.). To determine the diffusion coefficient, the method of Fokker-Planck equation derivation was used. A formula is presented for calculating the radiation-stimulated diffusion coefficient. A linear growth of the diffusion coefficient with radioactivity is noted according to the formula, the diffusion coefficient is mainly determined by the field in the radiation damage region. The aerosol radioactivity may result in a more rapid deposition of aerosols in the pipelines and aerosol purification systems. The diffusion rate grows not only in the presence of intrinsic radioactivity but in case of external radiation exposure as well.

1984-04-01

360

Method for the reduction of radioactivity of some building materials  

International Nuclear Information System (INIS)

A few industry-derived and conventional building materials have above acceptable radioactivity. An examination of some materials presently used, or with a potential for use, has shown that in phosphogypsum, fly ash, zircon kyanite tailings, red mud and brickmaking clay, the radium equivalent activities of the finer fractions (<53 #mu#) are higher than those of the larger fractions. Consequently, the radioactivity of these materials could be reduced by dry-sieving and discarding the fines. In blast furnace slag and dissociated zircon, no such reduction would occur since the radioactivity is evenly distributed in all sized fractions.

361

Measurements and evaluations of nuclear data on actinide isotopes  

International Nuclear Information System (INIS)

The measurements of the nuclear decay of actinide isotopes and the evaluation of the radioactive properties of nuclide with the mass 242 is discussed in this paper.

1979-08-01

362

Legal Analysis of the Korea Radioactive Waste Management Act in the aspect of IAEA Principles  

International Nuclear Information System (INIS)

According to the Principles of Radioactive Waste Management, the IAEA SAFETY SERIES NO-111-F, IAEA declared 9 doctrines. The IAEA advised a country that operates nuclear power plant to adopt the principles. As a member of the IAEA, Korea has also discussed about a unified policy and enacting law for radioactive waste management to follow the doctrines. This study analyzed the recently enacted Korea Radioactive Waste Management Act and verified whether the Act successfully follows the doctrine or not

2009-05-01

363

Iodine decontamination factor for liquid radioactive waste volume reduction system  

International Nuclear Information System (INIS)

(Jun 1976). United States Tokerud, LD Garcia, R. Aerojet Energy Conversion

1976-06-13

365

Astronautics and Aeronautics, 1974 - NASA History Office  

Science.gov (United States)

The congressional Joint Committee on Atomic Energy issued the panel report Transportation of Radioactive Material by Passenger Aircraft. ...

367

A pilot plant demonstration of the vitrification of radioactive solutions using microwave power  

Energy Technology Data Exchange (ETDEWEB)

A process has been developed that exploits the characteristics of microwave heating for the vitrification of high-level radioactive liquid waste. This process, microwave vitrification, has been successfully operated at pilot plant scale in an active cell using simulated liquid waste containing several curies of radioactivity. Excellent decontamination factors have been achieved for both volatiles and nonvolatiles with an average ruthenium decontamination factor of 490 and a gross alpha emitter decontamination factor of 100,000. Almost all the radioactivity is incorporated in a glass block.

1986-01-01

368

A pilot plant demonstration of the vitrification of radioactive solutions using microwave power  

International Nuclear Information System (INIS)

A process has been developed that exploits the characteristics of microwave heating for the vitrification of high-level radioactive liquid waste. This process, microwave vitrification, has been successfully operated at pilot plant scale in an active cell using simulated liquid waste containing several curies of radioactivity. Excellent decontamination factors have been achieved for both volatiles and nonvolatiles with an average ruthenium decontamination factor of 490 and a gross alpha emitter decontamination factor of 100,000. Almost all the radioactivity is incorporated in a glass block.

369
370

Recent status of the development of intense ion beams  

Energy Technology Data Exchange (ETDEWEB)

Taking the development of large current, negative ion sources which is in progress aiming at nuclear fusion reactors and the development of high luminance ion sources planned as a part of the Omega Project as the examples, the technology for generating high power ion beams is explained. Both these projects are positioned at the limit of the present technology of high power ion beam application as their targeted beam power reaches several tens MW. Consequently, the requirement for the ion sources is severe, and in particular, the generation of the ion beams having large current density with good convergence is beyond all precedents. The application of high power ion sources has been realized as the neutral beam injectors for large tokamaks. Also the hydrogen negative ion source of large current and the electrostatic ...

1993-12-01

371

Spatiotemporal Analysis of Environmental Radioactivity in Soil around Nuclear Plant  

Energy Technology Data Exchange (ETDEWEB)

Geostatistical techniques make it possible to qualitatively and quantitatively analyze spatiotemporal inherent characteristics of environmental radiation or radioactivity. Spatial patterns and trend analysis of environmental radioactivity, e.g., {sup 137}Cs and {sup 40}K, in soil around nuclear facilities (Kori, Wolsung, Yeonggwang, Uljin, and Daejeon) will be investigated and discussed.

2006-07-01

372

Radioactive waste  

Energy Technology Data Exchange (ETDEWEB)

The paper deals with the disposal of radioactive waste and the plans for dealing with solid wastes of intermediate and low levels of activity, which are the responsibility of NIREX. NIREX is an executive body which co-ordinates the waste-disposal plans of the main radioactive waste producers. The disposal routes for the active wastes are described including the deep disposal of wastes containing material that will remain active for thousands of years. Requirements for deep burial are outlined with reference to the geology and hydrogeology of the site. Monitoring, maintenance and surveillance are mentioned for the protection of the public.

1984-02-01

373

Organization of setting-up sanitary pass-control regime and sanitary treatment of injured persons in case of radiation accidents  

International Nuclear Information System (INIS)

The main aim of sanitary pass-control regime is to prevent propagation of radioactive contamination outside the area of emergency-rescue works and guarantee of sanitary treatment of all persons having radioactive contamination. The paper has studied the questions of organization of sanitary pass-control regime, arrangement of sanitary treatment of the injured persons and rendering first aid in case of radioactive contamination of wounds. 5 refs.

374

Moving Forward with Lessons Learned About Long-term Radioactive Waste Management  

Energy Technology Data Exchange (ETDEWEB)

A range of lessons have been identified from previous attempts to implement long term radioactive waste management policy in the UK and internationally. Many of these relate to the way the decision-making process is undertaken and the fact that there needs to be an open, transparent process that enables continuous stakeholder involvement. Nirex believes that using the SEA and EIA frameworks will help to incorporate the lessons learned into the future decision-making process relating to long-term radioactive waste management.

2006-09-15

375

Decommissioning of facility for use of radioisotopes on waste management and disposal facility  

Energy Technology Data Exchange (ETDEWEB)

All the tests have been finished up in the Waste Management and Disposal Facility which has been used for the safety tests of solidified radioactive waste on sea dumping disposal. The decommissioning of this facility was performed for use of radioisotopes. This report describes the plan on decommissioning of facility for use of radioisotopes, the contamination checking methods and measurement of radioactivity, the fore case and practice for amount of generated radioactive wastes, the operation procedures for dismantlement, the safety measures, the expenses for decommissioning and so on. (author)

1999-09-01

376

Characterisation of long-lived low and intermediate-level radioactive wastes in the Nordic Countries  

International Nuclear Information System (INIS)

The present report is final report from a study on characterisation of radioactive waters in the Nordic countries. The study has mainly been focused on long-lived low and intermediate level radioactive waste. Methods to measure or estimate the activity content and the general composition are discussed. Recommendations are given regarding characterisation of waste under treatment and characterisation of already produced waste packages. (au).

2005-01-01

377

Achievements and Perspectives of the Joint Convention on the Safety of Spent Fuel Management and on the Safety of Radioactive Waste Management  

International Nuclear Information System (INIS)

The Joint Convention on the Safety of Spent Fuel management and on the Safety of Radioactive Waste Management is the first legal instrument to directly address the safety of spent fuel and radioactive waste management on a global scale. The Joint Convention entered into force in 2001. This paper describes its process and its main achievements to date. The perspectives to establish of a Global Waste Safety Regime based on the Joint Convention are also discussed. (authors)

378

Strontium removal from caustic carbonate waste solutions using carrier coprecipitation  

Energy Technology Data Exchange (ETDEWEB)

A carrier coprecipitation procedures has been developed for the removal of radioactive strontium from caustic liquid low-level waste (LLLW) generated at Oak Ridge National Laboratory. The two-step treatment process involves the addition of normal Sr (as SrCl{sub 2}) to the waste matrix, which is composed primarily of 0.3 M NaOH and 0.6 M Na{sub 2}CO{sub 3}. The active Sr equilibrates with the normal Sr carrier and coprecipitates as SrCO{sub 3} at pH 13. A liquid/solid separation is made before the pH of the supernate is reduced to pH 8 with sulfuric acid. During the neutralization step, the aluminum is the waste precipitates as Al(OH){sub 3}. Further Sr decontamination is achieved as traces of active Sr sorb to the Al(OH){sub 3} that precipitates during the neutralization step. A final liquid/solid separation is made at pH 8 to remove the sorbed active Sr. Maximum Sr decontamination of the LLLW is obtained when at least 50 ppm normal Sr is added to the waste. ...

1994-12-31

379

Salt decontamination demonstration test results  

International Nuclear Information System (INIS)

The Salt Decontamination Demonstration confirmed that the precipitation process could be used for large-scale decontamination of radioactive waste sale solution. Although a number of refinements are necessary to safely process the long-term requirement of 5 million gallons of waste salt solution per year, there were no observations to suggest that any fundamentals of the process require re-evaluation. Major accomplishments were: (1) 518,000 gallons of decontaminated filtrate were produced from 427,000 gallons of waste salt solution from tank 24H. The demonstration goal was to produce a minimum of 200,000 gallons of decontaminated salt solution; (2) cesium activity in the filtrate was reduced by a factor of 43,000 below the cesium activity in the tank 24 solution. This decontamination factor (DF) exceeded the demonstration goal of a DF greater than 10,000; (3) average strontium-90 activity in the filtrate was reduced by a factor of 26 to less than 10"3 d/m/ml versus ...

380

Frontiers of Nuclear Astrophysics  

International Nuclear Information System (INIS)

The main goals of nuclear astrophysics have been to probe the interiors of stars, stellar explosions, the early moments of cosmic expansion, and the formation and evolution of galaxies and cosmic structure by measurement and application of the relevant nuclear physics. The approach to these goals have generally been from three directions: 1) Careful measurements of the relevant nuclear reactions; 2) Detailed computer models of the relevant astrophysical environments; and 3) Observations of the relevant terrestrial and extra-terrestrial atomic and isotopic abundances. These approaches provide not only insight into the formation and evolution of the elements, but are also pillars upon which a variety of cosmological models as well as models for physics beyond the standard model of particle physics can stand or fall. At present there is a very exciting frontier on all three of these approaches. The development and applications of radioactive-ion-beam and ...

2008-06-01

381

Decontamination of cesium, strontium, and cobalt from aqueous solutions by bentonite  

Energy Technology Data Exchange (ETDEWEB)

Sorption studies of cesium, strontium, and cobalt (Cs, Sr, and Co) on bentonite under various experimental conditions, such as contact time, pH, sorbent and sorbate concentration, and temperature, have been performed. The sorption data for all these metals have been interpreted in terms of Freundlich, Langmuir, and Dubinin-Radushkevich equations. Thermodynamics parameters, such as heat of sorption {Delta}H{degrees}, free energy change {Delta}G{degrees}, and entropy change {Delta}S{degrees}, for the sorption of these metals on bentonite have been calculated. The value of {Delta}H{degrees} shows that the sorption of Cs was exothermic, while the sorption of Sr and Co on bentonite were endothermic in nature. The value of {Delta}G{degrees} for their sorption was negative, showing the spontaneity of the process. The maximum loading capacity of Cs, Sr, and Co were 75.5, 22, and 27.5 meq, respectively, for 100 g of bentonite. The mean free energy E of Cs, Sr, and Co sorption on bentonite was ...

1996-12-31

382

Neutron beam experiments using nuclear research reactors: honoring the retirement of professor Bernard W. Wehring -II. 4. Accurate Characterization of the Shape of the HPGe Detector Peak Efficiency Curve for Application in PGNAA  

International Nuclear Information System (INIS)

In various situations, measurements in prompt gamma neutron activation analysis (PGNAA) are performed to determine the amount of an elemental impurity relative to that of a major constituent of the matrix. An example of this is the measurement of hydrogen concentration in a metallic matrix. In all such cases, a major contributor to the uncertainty in the measurement is the uncertainty in the ratio of the high-purity germanium (HPGe) detector full-energy peak efficiency for the gamma-ray lines of interest (i.e., impurity and matrix gammas). Usually, the ratio is derived from the relative peak efficiency curve, which is determined using isotopic standards that emit multiple gamma ray lines (e.g., "1"5"2Eu) in the energy range <3000 keV, or using prompt gamma radionuclides (e.g., "1"4N, "3"5Cl) in the energy range >3000 keV. In either case, the uncertainty in the ratio of the peak efficiency values derived from such measurements will be on ...

2001-06-17

383

Radioactive waste management in the USSR: A review of unclassified sources. Volume 2  

Energy Technology Data Exchange (ETDEWEB)

The Soviet Union does not currently have an overall radioactive waste management program or national laws that define objectives, procedures, and standards, although such a law is being developed, according to the Soviets. Occupational health and safety does not appear to receive major attention as it does in Western nations. In addition, construction practices that would be considered marginal in Western facilities show up in Soviet nuclear power and waste management operations. The issues involved with radioactive waste management and environmental restoration are being investigated at several large Soviet institutes; however, there is little apparent interdisciplinary integration between them, or interaction with the USSR Academy of Sciences. It is expected that a consensus on technical solutions will be achieved, but it may be slow in coming, especially for final disposal of high-level radioactive wastes and ...

1991-03-01

384

Radioactive waste management in the USSR: A review of unclassified sources  

Energy Technology Data Exchange (ETDEWEB)

The Soviet Union does not currently have an overall radioactive waste management program or national laws that define objectives, procedures, and standards, although such a law is being developed, according to the Soviets. Occupational health and safety does not appear to receive major attention as it does in Western nations. In addition, construction practices that would be considered marginal in Western facilities show up in Soviet nuclear power and waste management operations. The issues involved with radioactive waste management and environmental restoration are being investigated at several large Soviet institutes; however, there is little apparent interdisciplinary integration between them, or interaction with the USSR Academy of Sciences. It is expected that a consensus on technical solutions will be achieved, but it may be slow in coming, especially for final disposal of high-level radioactive wastes and ...

1991-03-01

385

Nigeria's radioactive waste management policy and strategy document  

International Nuclear Information System (INIS)

Radioactive waste for legal and regulatory purposes may be defined as material that contains or is contaminated with radio-nuclides at concentrations or activities greater than clearance levels as established by the regulatory body, and for which no use is foreseen. Safe management of radioactive waste is essential to ensure protection of humans and environment. Radioactive waste management policy is a guideline for the safe management of radioactive waste. It expresses the commitment of the country towards the goal. Government should initiate investigation into best long-term option for management of spent nuclear fuels. Process of selecting option and eventual site should involve comprehensive public participation within set time frames (with deep geological disposal as preferred management option).

2009-07-14

386

Development of a high current negative ion source for fusion application  

Energy Technology Data Exchange (ETDEWEB)

Negative ion based neutral beam injector is one of the most attractive heating system in future fusion reactors. In realizing the system, the crucial device which has to be developed is a high intensity negative ion source. Significant progress has been made on the negative ion source in these years. Among them, a few ampere negative ion beam were produced stably, while the divergence of negative ion beams becomes to be as low as < 10 mrad. We consider these results are demonstrating the potential of the negative ion source for the heating device in future reactors.

1988-11-01

387

The Waste Management Plan integration into Decommissioning Plan of the WWR-S research reactor from Romania  

International Nuclear Information System (INIS)

The paper presents the progress of the Radioactive Waste Management Plan which accompanies the Decommissioning Plan for research reactor WWR-S located in Magurele, Ilfov, near Bucharest, Romania. The new variant of the Decommissioning Plan was elaborated taking into account the IAEA recommendation concerning radioactive waste management. A new feasibility study for WWR-S decommissioning was also developed. The preferred safe management strategy for radioactive wastes produced by reactor decommissioning is outlined. The strategy must account for reactor decommissioning, as well as rehabilitation of the existing Radioactive Waste Treatment Plant and the upgrade of the Radioactive Waste Disposal Facility at Baita-Bihor. Furthermore, the final rehabilitation of the laboratories and reusing of cleaned reactor building is envisaged. An inventory of each type of ...

2008-05-28

388

Secondary ions from condensed gas solids by singly and multiply charged ion impacts  

International Nuclear Information System (INIS)

Ion desorption from a condensed gas solid Ne impacted by singly- and multiply-charged Ar"q"+ ions (q = 1-7) has been investigated. Various secondary ions such as cluster ions, Ne"+_n (n = 2-20) as well as atomic ions are observed. Mass spectral patterns, thickness dependence of the yields, and kinetic energy distributions of the desorbed Ne"+_n (n = 1,2) depend strongly on the projectile charge state. These results indicate that the dissipation of the projectile potential energy on the surface leads to the desorption of the monomer and small cluster ions by a Coulomb repulsion between adjacent target ions.

2009-11-01

389

Production of rare-earth atomic negative ion beams in a cesium-sputter-type negative ion source  

International Nuclear Information System (INIS)

The desire to study negative ion structure and negative ion-photon interactions has spurred the development of ion sources for use in research and industry. The many different types of negative ion sources available today differ in their characteristics and abilities to produce anions of various species. Thus the importance of choosing the correct type of negative ion source for a particular research or industrial application is clear. In this study, the results of an investigation on the production of beams composed of negatively-charged rare-earth ions from a cylindrical-cathode-geometry, cesium-sputter-type negative ion source are presented. Beams of atomic anions have been observed for most of the first-row rare-earth elements, with typical currents ranging from hundreds of picoamps to several nanoamps.

2007-08-01

390

Synthetic inorganic ion exchangers. XVI. Electrochromatographic separations of metal ions on zirconium tungstate-impregnated paper  

Energy Technology Data Exchange (ETDEWEB)

The electrochromatographic behavior of 25 metal ions on zirconium tungstate-impregnated papers is described. Six background electrolytes were used. On the basis of the differential mobilities of metal ions which depend on the ion-exchange properties of zirconium tungstate and the nature of complex formation with the electrolytes, some important binary and ternary separations have been achieved.

1980-03-01

391

Production by surface sputtering and acceleration of heavy negative ions in tandem accelerators  

Energy Technology Data Exchange (ETDEWEB)

The main physical processes allowing negative ion production by surface sputtering for further acceleration in tandem acceleration are briefly reviewed. The sputtering yield and the probability of negative ion ejection are discussed. The properties of negative ion beams for an efficient acceleration in tandem accelerators are also discussed, with an emphasis on space charge problems. The main features and performances of the heavy negative ion injector of the Bucharest tandem accelerator are given.

1992-10-05

392

Long pulse extraction of deuterium negative ion beams from the Kamaboko ion source  

Energy Technology Data Exchange (ETDEWEB)

Operation at ITER specifications of the Kamaboko III ion source for 1000 second pulses of deuterium negative ion beams is underway on the MANTIS test stand. Efficient production of negative ions at low arc power requires injection of cesium into the source, temperature control of the plasma grid, and a period of conditioning of several days. Two different concepts of temperature regulated plasma grids are currently being tested. (author)

1998-07-01

393

Coulomb Repulsion in Miniature Ion Mobility Spectrometry  

Energy Technology Data Exchange (ETDEWEB)

We have undertaken a study of ion mobility resolution in a miniature ion mobility spectrometer with a drift channel 1.7 mm in diameter and 35 mm in length. The device attained a maximum resolution of 14 in separating ions of NO, O{sub 2}, and methyl iodine. The ions were generated by pulses from a frequency-quadrupled Nd:YAG laser. Broadening due to Coulomb repulsion was modeled theoretically and shown experimentally to have a major effect on the resolution of the miniature device.

1999-08-08

394

Contribution of the ion-energy distribution to the current-density distribution of a focused-ion beam  

Energy Technology Data Exchange (ETDEWEB)

A general expression for the current-density distribution of a focused-ion beam (FIB) in the chromatic-aberration region is set up in the form of a definite integral. With the experimentally obtained ion-energy distribution of a liquid-metal ion source, its contribution to the FIB current-density distribution is estimated. Calculated results explain the wide-exponential tail of a FIB.

1987-09-01

395

Contribution of the ion-energy distribution to the current-density distribution of a focused-ion beam  

International Nuclear Information System (INIS)

A general expression for the current-density distribution of a focused-ion beam (FIB) in the chromatic-aberration region is set up in the form of a definite integral. With the experimentally obtained ion-energy distribution of a liquid-metal ion source, its contribution to the FIB current-density distribution is estimated. Calculated results explain the wide-exponential tail of a FIB.

396

Analytical determination of the dimensions and evolution with current of the ion-emitting jet in liquid-metal ion sources  

Energy Technology Data Exchange (ETDEWEB)

The apex dimensions and length are calculated as a function of current for the ion-emitting jet in liquid-metal ion sources (LMIS). The results agree well with observations. Since the final expressions are analytical, they give more insight into the fundamental mechanisms involved than do numerical calculations. Some implications of the model are discussed concerning focused ion beam (FIB) systems employing LMIS. (author).

1991-12-14

397

Study of the {sup 60}Co speciation in the aqueous radioactive waste of the la Hague nuclear reprocessing plant; environmental behaviour after discharges in the waters of the channel; Etude de la speciation du {sup 60}Co dans les effluents de l'usine de retraitement de combustibles irradies de la Hague; devenir apres rejet dans les eaux de la Manche  

Energy Technology Data Exchange (ETDEWEB)

{sup 60}Co is produced as an activation product and is present in the low-level aqueous radioactive waste released from the La Hague plant. At present, the concentration in the sea (non filtered at 0.45 {mu}m) at the Goury site are close to or even below, the detection limit: 0.2 mBq.l{sup -1}. The {sup 60}Co speciation depends on the type of effluent considered: in the effluent A ('active'), the cobalt is in the form of a stable trivalent complex; in the effluent V (to be checked), the cobalt is in majority (50% of the activity release) in the form of particles (>0.45 {mu}m), and then in the form of two soluble species: ionic divalent (Co{sup 2+}) and some stable complexes. The evolution of the reprocessing techniques used does not affect the speciation. So, since the nuclear reprocessing plant started at the La Hague plant in 1966, the chemical species discharged in the sea shows time variation related to the evolution of the type of ...

1999-07-01

398

Variability and spectral modeling of the hard X-ray emission of GX 339-4 in a bright low/hard state  

CERN Document Server

We study the high-energy emission of the Galactic black hole candidate GX 339-4 using INTEGRAL/SPI and simultaneous RXTE/PCA data. By the end of January 2007, when it reached its peak luminosity in hard X-rays, the source was in a bright hard state. The SPI data from this period show a good signal to noise ratio, allowing a detailed study of the spectral energy distribution up to several hundred keV. As a main result, we report on the detection of a variable hard spectral feature (>150 keV) which represents a significant excess with respect to the cutoff power law shape of the spectrum. The SPI data suggest that the intensity of this feature is positively correlated with the 25 - 50 keV luminosity of the source and the associated variability time scale is shorter than 7 hours. The simultaneous PCA data, however, show no significant change in the spectral shape, indicating that the source is not undergoing a canonical ...

2010-01-01

399

Energetic electrons in impulsive and extended solar flares as deduced from flux correlations between hard X-rays and microwaves  

Energy Technology Data Exchange (ETDEWEB)

The peak flux relationship between hard X-rays and microwaves from solar flares is studied using about 400 events simultaneously recorded with the hard X-ray burst spectrometer on the SMM satellite and the Nobeyama 17 GHz radiometer. The data indicate that the hard X-ray and microwave peak fluxes correlate best for X-ray energies of less than about 80 keV for impulsive flares and greater than about 360 keV for extended flares. By postulating that electrons responsible for microwave emission at 17 GHz are those emitting hard X-rays at these photon energies, it is concluded that: (1) in impulsive flares, microwaves at about 20 GHz are emitted mainly by electrons of less than about 200 keV from a layer through which the electrons stream down into the thick-target hard X-ray source; and (2) in extended flares, microwaves are emitted mainly by MeV electrons trapped in a coronal loop or loops. 59 references.

1988-01-01

400

Accretion Properties of A Sample of Hard X-ray (<60keV) Selected Seyfert 1 Galaxies  

CERN Document Server

We examine the accretion properties in a sample of 42 hard (3-60keV) X-ray selected nearby broad-line AGNs. The energy range in the sample is harder than that usually used in the similar previous studies. These AGNs are mainly complied from the RXTE All Sky Survey (XSS), and complemented by the released INTEGRAL AGN catalog. The black hole masses, bolometric luminosities of AGN, and Eddington ratios are derived from their optical spectra in terms of the broad H$\\beta$ emission line. The tight correlation between the hard X-ray (3-20keV) and bolometric/line luminosity is well identified in our sample. Also identified is a strong inverse Baldwin relationship of the H$\\beta$ emission line. In addition, all these hard X-ray AGNs are biased toward luminous objects with high Eddington ratio (mostly between 0.01 to 0.1) and low column density ($<10^{22} \\mathrm{cm^{-2}}$), which is most likely due to the selection effect of the surveys. The hard ...

2008-01-01

401

Progress report on negative ion beams based on User Development Workshop on negative ion based neutral beams, 15-16 February, 1983, Princeton  

International Nuclear Information System (INIS)

Progress in the development of negative ion sources and their application in fusion research is reviewed. (U.K.).

1983-04-18

403

Pore region of TRPV3 ion channel is specifically required for heat-activation  

UK PubMed Central (United Kingdom)

Ion-channels can be activated (gated) by a variety of stimuli including chemicals, voltage, mechanical force or temperature. Whereas molecular mechanisms of ion-channel gating by chemicals and...Full Text Available

2008-09-01

404

Mean distance of closest approach of alkaline-earth metals ions in aqueous solutions: Experimental and theoretical calculations  

British Library Electronic Table of Contents (United Kingdom)

The estimation of numerical values of the mean distance of closest approach of ions, a, of alkaline-earth metal ion salts in aqueous solutions, determined from activity coefficients, as well as from different theoretical approaches, is presented and discussed.

2010-01-01

405

Low energy focused ion beams  

Energy Technology Data Exchange (ETDEWEB)

The performance of the PSI/ETH focused ion beam (FIB) system has been improved to produce ion beams of very low energies down to 40 eV with a reasonable spot size of 1 {mu}m at 200 eV. (author) 2 figs., 1 ref.

1996-10-01

406

Ion clustering in aqueous solutions probed with vibrational energy transfer  

UK PubMed Central (United Kingdom)

Despite prolonged scientific efforts to unravel the hydration structures of ions in water, many open questions remain, in particular concerning the existences and structures of ion clusters in 1∶1...Full Text Available

2011-03-22

407

Cluster-assisted multiple ionization of methyl iodide by a nanosecond laser: Influence of laser intensity on the kinetic energy and peak profile of multicharged ions  

International Nuclear Information System (INIS)

The dependences of kinetic energies and peak profiles of multicharged ions of I "q"+ (q = 2-3) and C"2"+ on the laser intensity have been studied in detail by time-of-flight mass spectrometry, those multicharged ions are produced by irradiation of methyl iodide cluster beam with a nanosecond 532 nm Nd-YAG laser. Our experiments show that the kinetic energies released of multicharged ions increase linearly with the laser intensity in the range of 3 x 10"9-2 x 10"1"1 W/cm"2. The peaks of multicharged ions are split to forward ions and backward ions, and the ratio of the backward ions to forward ions decreases exponentially with laser intensity. The decreasing of backward ions is probably due to Coulomb scattering by the heavier I"+ ions when they turn around through the laser focus ...

2006-03-20

408

Total M shell X-ray production cross sections and average fluorescence yields in 11 elements from Tm to U at photon energy of 5.96 keV  

International Nuclear Information System (INIS)

Total M shell X-ray production cross section for 11 elements with 69 #<=# Z #<=# 92 have been measured using an incident photon energy of 5.96 keV. Measurements have been performed using an "5"5Fe annular source and a Si(Li) detector. Average M shell fluorescence yield at each incident photon energy has been deduced, using the experimental total M X-ray production cross section and theoretical M shell photoionization cross section. Present experimental results are compared with other experimental and theoretical values. Reasonable agreement (to within 0.3-28%) is typically obtained between present and other experimental and theoretical values.

2005-04-01

409

The Micro-X Imaging Spectrometer Instrument  

Science.gov (United States)

The Micro-X instrument is a NASA funded, rocket borne X-ray imaging spectrometer planned for launch in January 2011. An array of Transition Edge Sensors (TESs) will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. This will be a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat sink, and will be read out by a SQUID time division multiplexer. X-rays will be focused onto the TES array of 128 pixels on a 600 micron pitch by a conically approximated Wolter optic with an effective area of 200 cm2. The spectrometer will have a field of view of 11.8 arcmin. We describe the design and development progress of the instrument.

2010-01-01

410

Study of point defect detectors in Si  

International Nuclear Information System (INIS)

The importance of point defects in semiconductor and function materials has been studied in detail, but effective means for detecting point defects has not been available for a long time. The end of range defects in Si, produced by 140 keV Ge"+ implantation, were investigated as detectors for measuring the interstitial concentration created by 42 keV B"+ implantation. The concentration of interstitial resulting from the B"+ implantation and the behavior of the interstitial flux under different annealing condition were given. The enhanced diffusion in the boron doped EPI marker, resulting from mobile non-equilibrium interstitials was demonstrated to be transient. Interstitial fluxes arising from processing can be detected by transient enhanced diffusion (TED) of doped marker layers as well

1999-05-01

411

Study of "1"0"1Mo decay  

International Nuclear Information System (INIS)

The decay of "1"0"1Mo to levels in "1"0"1Tc has been studied using the three-parameter (#gamma#-#gamma#-t) coincidence system of HpGe-HpGe detectors. From the coincidence data, the new decay scheme was constructed. The previously reported 104.70, 105.95 and 774.15 keV #gamma# rays were observed, and have been assigned to the decay scheme for the first time. A newly observed 1508.01 keV #gamma# ray has also been assigned to the scheme for the first time. The intensities of #beta#"- and the values of log ft to most levels were calculated

2000-04-01

412

Structure of Heavy Fe Nuclei at the Point of Transition at N #approx# 37  

International Nuclear Information System (INIS)

We have studied energy levels in "6"3Fe populated in the #beta#-decay of "6"3Mn. A new (preliminary) level scheme of "6"3Fe includes 10 excited states connected by 21 #gamma#-rays. The first excited states at 357 and 451 keV have the level half-lives of 110 ps and 780 ps, respectively. Three states, at 357, 451 and 1132 keV, are strongly #beta#-fed with log ft #approx# 5, while there is only a very week #beta#-feeding, if any at all, to the ground state. The new results imply that "6"3Fe departs from a simple shell model structure observed for heavier N = 37 isotones of "6"5Ni and "6"7Zn. (author)

2009-03-01

413

Photon-induced L-shell x-ray intensity ratio for elements with 73 #<=# Z #<=#83 in the energy range 17 #<=# E #<=# 47 keV  

International Nuclear Information System (INIS)

The L-shell x-ray intensity ratios I(L_#beta#)/I(L_#alpha#) and I(L_#gamma#)/I(L_a_l_p_h_a) for elements with 73 #<=# Z #<=# 83 have been measured at photon incident energies of 17.8, 25.8 and 46.9 keV. The emitted x-rays were measured with a Si(Li) detector system. The results for Re, Pt and Tl are being reported for the first time. A comparison is made of the experimental results with the calculated values obtained by using the theoretical x-ray emission rates, subshell ionisation cross sections, subshell fluorescence yields and Coster-Kronig transition probabilities. The experimental results are in reasonable agreement with the theoretical values. (author).

1988-01-01

414

On Low Energy Levels in 185W  

International Nuclear Information System (INIS)

Gamma ray spectra in the decay of 185Ta and 185mW have been studied with Ge (Li) detectors. The 185mW isomeric transition at 131.6 keV is shown to be of E3 multipolarity. A level scheme of 185W is proposed with the following energy levels (energies in keV, spin and K quantum numbers in brackets): 0 (3/2- 3/2), 23.5 (1/2- 1/2), 65.9 (5/2- 3/2), 93.5 (3/2- 1/2) (uncertain), 173.9 (7/2- 3/2), 188.1 (5/2- 1/2), 197.5 (11/2+ 11/2) , 243.5 (7/2- 7/2), and 390.8 (9/2- 7/2)

1996-03-04

415

Nuclear structure studies via neutron interactions  

Energy Technology Data Exchange (ETDEWEB)

Research preformed consisted of: (1) publication of an experimental paper for the n + {sup 40}Ar high resolution total cross section and submission of a theoretical paper dealing with the prediction of the average parameters deduced from the the data; (2) preliminary R-matrix analysis of the neutron total cross section data for the n + {sup 208}Pb systems, up to an energy of 1.7 MeV; (3) completed the analysis of neutron total cross section of data for n + {sup 54}Fe up to energy of 500 keV, with j{sup {pi}} values confirmed, in most cases, by differential scattering data; (4) analysis of total cross section data for the n + {sup 88}Sr system up to an energy of 175 keV; (5) development of a graphical interface for the code RFUNC, used to calculate the differential scattering cross sections, for comparison with measurements.

1991-03-01

416

Monte Carlo code comparisons for the calculation of absorbed dose per unit fluence in slab phantoms for electron energies from 50 keV to 10 MeV  

International Nuclear Information System (INIS)

The MCNPE-BO and MCNP4 Monte Carlo electron-photon codes were used to calculate the dose equivalent per unit fluence at various depths in tissue-equivalent slab phantoms for broad parallel beams of monoenergetic electrons with energies from 50 keV to 10 MeV. The study was carried out in the framework of the activities of a ICRP/ICRU Joint Task Group with the support of EURADOS WG4 (Numerical Dosimetry). Some preliminary results and comparisons as well as a general discussion on the performances of the codes are presented, demonstrating quite a satisfactory agreement among the results obtained using the two codes and those of other authors. (author).

417

Monte Carlo characterization of an ytterbium-169 high dose rate brachytherapy source with analysis of statistical uncertainty  

International Nuclear Information System (INIS)

An ytterbium-169 high dose rate brachytherapy source, distinguished by an intensity-weighted average photon energy of 92.7 keV and a 32.015#+-#0.009 day half-life, is characterized in terms of the updated AAPM Task Group Report No. 43 specifications using the MCNP5 Monte Carlo computer code. In accordance with these specifications, the investigation included Monte Carlo simulations both in water and air with the in-air photon spectrum filtered to remove low-energy photons below 10 keV. TG-43 dosimetric data including S_K, D(r,#theta#), #LAMBDA#, g_L(r), F(r,#theta#), #phi#_a_n(r), and #phi#_a_n were calculated and statistical uncertainties in these parameters were derived and calculated in the appendix.

2006-01-01

418

Light emission from hydrogen-copper interaction at grazing incidence  

Energy Technology Data Exchange (ETDEWEB)

The optical emission of excited H reflected from clean Cu(110) after impingement of H/sup +/ and H/sub 2//sup +/ in the energy range of 250 eV to 20 keV per nucleon at 70/sup 0/ angle of incidence to the surface normal was measured. For incident 10 keV H/sub 2//sup +/, the highest excited hydrogen state detected was the n=10 level. The Hsub(..cap alpha..) yield was found to be fluence and energy dependent. This effect is attributed either to fast sputtered hydrogen, surface roughness or to an increase with hydrogen concentration in electron states of p-like symmetry near the Fermi level of copper. The Hsub(..cap alpha..) yield per reflected nucleon shows approximately an exponential dependence on both projectile energy per nucleon and scattered particle reciprocal velocity perpendicular to the surface.

1984-03-01

419

Light emission from hydrogen-copper interaction at grazing incidence  

International Nuclear Information System (INIS)

The optical emission of excited H reflected from clean Cu(110) after impingement of H"+ and H_2"+ in the energy range of 250 eV to 20 keV per nucleon at 70"0 angle of incidence to the surface normal was measured. For incident 10 keV H_2"+, the highest excited hydrogen state detected was the n=10 level. The Hsub(#alpha#) yield was found to be fluence and energy dependent. This effect is attributed either to fast sputtered hydrogen, surface roughness or to an increase with hydrogen concentration in electron states of p-like symmetry near the Fermi level of copper. The Hsub(#alpha#) yield per reflected nucleon shows approximately an exponential dependence on both projectile energy per nucleon and scattered particle reciprocal velocity perpendicular to the surface. (orig.).

1983-07-01

420

Diffraction applications using the energy dispersive beamline X6A at the National Synchrotron Light Source  

Energy Technology Data Exchange (ETDEWEB)

The energy dispersive beamline X6A at the National Synchrotron Light Source employs a curved crystal monochromator (polychromator) which focuses a range ([similar to]1 keV) of x-ray energies into a narrow (100--120 [mu]m) line image. Although this beamline was constructed primarily for time-dependent EXAFS experiments, we have begun to explore the use of this instrument for energy dispersive diffraction experiments with different types of sample including macromolecular crystals. The tunability ([ital E]=6.5 to 21 keV) and flexibility ([Delta][ital E]=100--1000 eV) of the instrument makes the beamline ideal as a test bed for the application of polychromatic single-crystal diffraction techniques to different chemical or biological materials.

1995-02-01

421

Determination of ratios of emission probabilities of Auger electrons and K-L-shell radiative vacancy transfer probabilities for 17 elements from Mn to Mo at 59.5keV  

Energy Technology Data Exchange (ETDEWEB)

The measurements of the K X-ray intensity ratio I(K{sub {beta}})/I(K{sub {alpha}}) for the 17 elements Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Br, Rb, Sr, Y, Zr, Nb and Mo have been done following ionization by 59.5keV {gamma}-rays from a {sup 241}Am point source. Ratios of emission probabilities of Auger electrons and the vacancy transfer coefficients have been extracted in terms of the intensity ratios. It is found that the present results agree well with earlier fitted values and the semi-empirical values.

2006-01-15

422

Characteristics of wave-particle interaction in a hydrogen plasma  

International Nuclear Information System (INIS)

We study the characteristics of cyclotron wave-particle interaction in a typical hydrogen plasma. The numerical calculations of minimum resonant energy Emin, resonant wave frequency ?, and pitch angle diffusion coefficient D?? for interactions between R-mode/L-mode and electrons/protons are presented. It is found that Emin decreases with ? for R-mode/electron, L-mode/proton and L-mode/electron interactions, but increase with ? for R-mode/proton interaction. It is shown that both R-mode and L-mode waves can efficiently scatter energetic (10 keV-100 keV) electrons and protons and cause precipitation loss at L=4, indicating that perhaps wave-particle interaction is a serious candidate for the ring current decay. (authors)

2008-09-01

423

Structural and magnetic studies on the enhancement of the giant magnetoimpedance by ion irradiation  

British Library Electronic Table of Contents (United Kingdom)

The mechanism of abrupt increase of the giant magneto impedance (GMI) ratio in the ion irradiated Co-based amorphous ribbon has been investigated. The grazing incident X-ray diffraction and transmission electron microscope were used to characterize the samples before and after ion irradiation. The GMI-ratio considerably increased in the ion irradiated samples and the GMI response showed strong dependence on the driving frequencies. The Barkhausen noise (BN) signals are increased for the Ar ion irradiated sample with dose of 1x10^1^7 ion/cm^2. The results are interpreted in terms of GMI variation associated with domain wall dynamics.

2011-01-01

424

Large ion beams, fundamentals of generation and propagation  

Energy Technology Data Exchange (ETDEWEB)

This book is a compliation and analysis of discussions of phenomena important to ion beams and high perveance ion beams. This text discusses physics essential to research on ion beam generation and propagation and provides some requisite background to understanding the criteria for designing electrodes. Ion sources are categorized in terms of their configurations, and the relationships between various types of sources is developed. Covers collisionless space charge phenomena, collisionless plasmas, collisional effects and the taxonomy of high poissance beams. Chapters also treat the field of intense negative ion beams.

1987-01-01

425

Ion-Specific Hydration Effects: Extending the Poisson-Boltzmann Theory  

CERN Document Server

In aqueous solutions, dissolved ions interact strongly with the surrounding water, thereby modifying the solution properties in an ion-specific manner. These ion-hydration interactions can be accounted for theoretically on a mean-field level by including phenomenological terms in the free energy that correspond to the most dominant ion-specific interactions. Minimizing this free energy leads to modified Poisson-Boltzmann equations with appropriate boundary conditions. Here, we review how this strategy has been used to predict some of the ways ion-specific effects can modify the forces acting within and between charged interfaces immersed in salt solutions.

2011-01-01

426

Ion funnel with extended mass range and reduced conductance limit aperture  

Energy Technology Data Exchange (ETDEWEB)

An improved ion funnel design is disclosed that decreases the axial RF (parasite) fields at the ion funnel exit. This is achieved by addition of one or more compensation electrodes after the conductance limit electrode. Various RF voltage profiles may be applied to the various electrodes minimizing the parasite axial potential wells. The smallest RF aperture that serves as the conductance limiting electrode is further reduced over standard designs. Overall, the ion funnel improves transmission ranges of both low m/z and high m/z ions, reducing RF activation of ions and decreasing the gas load to subsequent differential pumping stages.

2008-04-01

427

Collective ion acceleration by a reflexing electron beam: model and scaling. Memorandum report  

Energy Technology Data Exchange (ETDEWEB)

Analytical and numerical calculations are presented for a reflexing electron beam type of collective ion accelerator. These results are then compared to those obtained through experiment. By constraining one free parameter to experimental conditions, the self-similar solution of the ion energy distribution agrees closely with the experimental distribution. Hence the reflexing beam model appears to be a valid model for explaining the experimental data. Simulation shows in addition to the agreement with the experimental ion distribution that synchronization between accelerated ions and electric field is phase unstable. This instability seems to further restrict the maximum ion energy to several times the electron energy.

1984-05-11

428

A new scheme of the longitudinal emittance measurement for negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

A new scheme of the longitudinal emittance measurement for high energy negative ion beam is proposed. The energy distribution of the detached electron from the negative ions by the photodetachment process, if the photon energy is almost equal to the electron binding energy of the negative ion (=electron affinity of the atom), reflects that of the original negative ions. Therefore, by introducing the photon in a short width comparing with the bunch width of the negative ion beam, the longitudinal energy distribution of each phase of the beam, that is the longitudinal emittance, can be measured. (author).

1995-08-01

429

The numerical simulation on low-level radioactive waste water, low-temperature cooling water drained effect of implement from the Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

In this paper, we calculated the radioactive concentration distribution of radioactive waste water, the temperature distribution of drained cooling water and the effect of implement from the Daya Bay Nuclear Power Plant on nearby waters range, discussed and analysed some problems of computational results and computation with Alternating Direction Implicit Method (ADI). The contents of the article included: the establishment of two-dimension tidal current equation, radioactive waste water pollutant dispersion equation and cooling water heat convection diffusion equation, the numerical difference calculation model of tidal current field, concentration field as well as temperature field, effect impingement with ADI method, numerical calculation results. The result of research showed that: when the Daya Bay Nuclear Power Plant is on normal operation and after the low level radioactive waste water and low ...

430

Proceedings of the workshop on radioactivity associated with coal use  

Energy Technology Data Exchange (ETDEWEB)

A workshop on radioactivity in coal use was held on September 15 through 17, 1981, under the auspices of the US Department of Energy, Office of Environmental Programs, and the Los Alamos National Laboratory. The purpose of the workshop was to identify research issues associated with radioactivity resulting from the use of coal for electric power generation. The concensus of the 10 scientists participating in the workshop was that a moderate to strong need exists for research in solubility of fly ash in different fluids and for determination of radioactivity in construction materials. Several additional research issues were identified but were given a lower priority. Summaries of each presentation are included. Titles are: some effects of coal combustion on the radiation environment; radionuclides in western coal at Mound; low-level radiation in coals utilized and ashes produced at New York State electric utilities; ...

1981-12-01

432

Studies of relativistic heavy ion collisions at the AGS (Experiment 814)  

Energy Technology Data Exchange (ETDEWEB)

This report discusses the experimental setup of experiment 814 at Brookhaven AGS. This experiment involves the collision of silicon ions with target nuclei. The detector systems are discussed primarily. (LSP)

1990-01-01

433

Selective radiochemical separation for indium determination at ppb levels in ion-implanted semiconductor-grade silicon  

Energy Technology Data Exchange (ETDEWEB)

A specific radiochemical procedure for indium determination in semiconductor-grade silicon, using an inorganic ion exchanger (cerium oxalate) is proposed.

1982-12-23

434

New and old Sn isomers produced in heavy-ion collisions  

International Nuclear Information System (INIS)

The energy level schemes of tin isotopes produced in the heavy ion reactions are presented. The using of #gamma# spectroscopy technique is also described. 4 refs, 12 figs.

1991-12-01

435

Kinetic energy dependence of the reactions of N"+ ions with NO, CO, CO_2, N_2O and SO_2  

International Nuclear Information System (INIS)

... kinetics chemical reactions energy dependence ion-molecule collisions milli

1977-07-01

436

Ion nitriding; Proceedings of the International Conference, Cleveland, OH, Sept. 15-17, 1986  

Energy Technology Data Exchange (ETDEWEB)

The present conference discusses plasma-assisted surface coating/modification processes, the applications to date of ion nitriding, the effects of nitrogen on metal surfaces, ion nitriding mechanisms in Cr, Al and Cr + Al-containing 1040 steel, ion nitriding of Al and its alloys, life enhancement for forging dies, novel anode plasma nitriding developments, and a comparative study of the pulsed and dc ion-nitriding behavior in specimens with blind holes. Also discussed are the influence of heating method on ion nitriding, surface hardening of marage steels by ion nitriding without core hardness reduction, plasma nitriding of nodular cast iron sput gears, NbN composites for superconductors, the carburization of tungsten in a glow discharge methane plasma, economic considerations concerning plasma nitriding, and the corrosion properties obtained by ...

1987-01-01

437

Induction and Repression of Nitrate Reductase in Neurospora crassa  

UK PubMed Central (United Kingdom)

Synthesis of wild-type Neurospora crassa assimilatory nitrate reductase is induced in the presence of nitrate ions and repressed in the presence of ammonium ions. Effects of several...Full Text Available

1978-02-01

438

First ion beam transfered from the SPS to the LHC  

CERN Multimedia

An ion beam has been successfully transfered from the SPS to the LHC for the first time on 12 November 2007.

2007-01-01

439

Accelerator-based analytical techniques using ion and photon beams. Environmental and industrial applications  

International Nuclear Information System (INIS)

An overview of different Ion Beam Analysis (IBA) techniques is given. Examples of applications of the PIXE techniques to various types of samples are presented. (author)

1999-11-01

440

The protective role of ceramic filters against natural radioactivity of water  

International Nuclear Information System (INIS)

The paper presents results of measurements of the natural radioactivity of tap water where samples were taken in front of, and behind the ceramic filter commonly used in houses for the purification of tap water. Altogether, 289 samples were taken, processed and measured during 1985-1986 in Kuwait. Results reveal the fact that ceramic filters reduce substantially the natural radioactivity in water (the 'gross' alpha activity reduced by the factor 2.18 #+-# 18%; the 'gross' beta by 1.53 #+-# 1.6%. (author).

441

The development of automatic surface dose-rate measuring and recording system for radioactive waste drum  

International Nuclear Information System (INIS)

The system which is performed the transportation and measurement of drum automatically to measure the surface dose-rate of radioactive waste drum and can inspect place of contaminated sources and precise dose-rate within a drum according to measuring many places equally at the same time has been developed. It is expected that the system be used to minimized radiation exposure of workers and manage the drum effectively according to established at the production facilities as well as the radioactive waste treatment facilities. (author). 7 refs., 9 tabs., 16 figs.

442

Survey of radiation protection programmes for transport; Etude des programmes de radioprotection pour les transports de matieres radioactives  

Energy Technology Data Exchange (ETDEWEB)

The survey of radiation protection programmes for transport has been jointly performed by three scientific organisations I.P.S.N. (France), G.R.S. ( Germany), and N.R.P.B. (United kingdom) on behalf of the European Commission and the pertaining documentation summarises the findings and conclusions of the work that was undertaken with the principal objectives to provide guidance on the establishment, implementation and application of radiation protection programmes for the transport of radioactive materials by operators and the assessment and evaluation of such programmes by the competent authority and to review currently existing radiation protection programmes for the transport of radioactive materials. (N.C.)

2001-07-01

443

Reflections on a future international convention on safety in radioactive waste management - September 1994  

Energy Technology Data Exchange (ETDEWEB)

This probably is a suitable moment for work to begin on an international Convention in this area, although it is a difficult task. Generally speaking, the RADWASS (Radioactive Waste Safety Standards) Programme has achieved sufficient consensus, and might serve as an important basis for work in relation to the Convention. The Convention should not go into highly technical details since consensus at this level is more difficult at the present moment, although this will undoubtedly be achieved in the medium term. An important element of the Convention should be the regulation of movements of radioactive wastes at international level. (orig./HP)

1995-12-31

444

Process and system for treatment of radioactive waste  

Energy Technology Data Exchange (ETDEWEB)

In a treatment system of radioactive waste solution including sodium sulfate generated from a boiling water type nuclear reactor, waste solution is fed into a thin film evaporator where the waste solution is evaporated and made into powder while precipitating in a peripheral surface of the evaporator vessel. The surface of the precipitated solid is wiped by rotating wiper blades and removed off as radioactive solid powder. The rotational speed of a rotor to which the wiper blades are secured is controlled at a minimum and necessary rotational speed which contributes to make the waste solution into the powder so that the rate of worn out of the wiper blade is decreased.

1985-07-02

445

Mastery of risks: we build the memory of radioactive waste disposal facilities  

International Nuclear Information System (INIS)

The ANDRA, the French national agency of radioactive wastes, is organizing today the information needs of tomorrow. The aim is to allow the future generations to have access to the knowledge of the existence of subsurface radioactive waste facilities and to understand the context and technologies of such facilities. The storage of this information is made on 'permanent paper', a high resistant paper with a lifetime of 600 to 1000 years. An updating of these data is made every 5 years for each waste disposal center. Another project, still in progress, concerns the memory management of deep geologic waste disposal facilities for which the time scale to be considered is of the order of millennia. (J.S.)

446

High energy beams of radioactive nuclei and their biomedical applications  

Energy Technology Data Exchange (ETDEWEB)

It is possible to produce energetic beams of radioactive nuclei, as secondary beams, from the heavy-particle compound accelerator called BEVALAC. These beams can be focused into experimental areas without significant contamination using suitable magnetic filters and proper beam-optics. Properly selected high-energy beams of radioactive nuclei (those which defay by positron emission) can provide a truly unique opportunity to evaluate the effectiveness of these beams in localizing the Bragg peak on a tumor volume - necessary in heavy-particle therapy. Preliminary data are presented here to demonstrate the possible use of these beams in radiotherapy treatment-planning verification.

1981-04-01

447

Experimental study on the volatile ruthenium decontamination factor of the perforated plate column scrubber  

International Nuclear Information System (INIS)

During a high temperature treatment of the radioactive wastes that contain ruthenium, some ruthenium is volatilized and released to the off gas system. The volatilized ruthenium is removed with a scrubber and an adsorber. It was expected that the scrubber was one of the most effective equipments to remove ruthenium and the decontamination factor of the scrubber was studied. The experimental apparatus was simulated as part of an actual perforated plate column scrubber. The non-radioactive ruthenium which simulated the radioactive ruthenium was volatilized and fed into the scrubber. The decontamination factor of the scrubber was determined by the ratio of the ruthenium concentration at the inlet and outlet of the scrubber off gas stream. The results showed that the scrubber removed the volatile ruthenium effectively as expected.

1993-07-01

448

Device for increasing the decontamination factor in the treatment of radioactive waste water. Vorrichtung zur Erhoehung der Dekontaminationsfaktoren bei der Aufbereitung radioaktiver Abwaesser  

Energy Technology Data Exchange (ETDEWEB)

In the well-known devices for increasing the decontamination factor in the treatment of radioactive waste water by evaporation, which consist of narrowing devices with evaporator sump and condenser, droplets of liquid and solid particles are carried over from the breeder space, which are radioactive and therefore make the decontamination factor worse. Better results are obtained if one places a fibre bed filter between the evaporator sump and the condenser, preferably in a horizontal connecting pipe between the evaporator sump and the condenser.

1982-06-09

449

Characterization of nuclear fuels by ICP mass-spectrometric techniques  

British Library Electronic Table of Contents (United Kingdom)

Isotopic analyses of radioactive materials such as irradiated nuclear fuel are of major importance for the optimization of the nuclear fuel cycle and for safeguard aspects. Among the mass-spectrometric techniques available, inductively coupled plasma mass spectrometry (ICP-MS) and thermal ionization mass spectrometry are the most frequently applied methods for nuclear applications. Because of the low detection limits, the ability to analyze the isotopic composition of the elements and the applicability of the techniques for measuring stable as well as radioactive nuclides with similar sensitivity, both mass-spectrometric techniques are an excellent amendment to classical radioactivity counting methods. The paper describes selected applications of multicollector ICP-MS in combination with c...

2008-01-01

450

The mobility of anthropogenic {sup 129}I in a shallow sand aquifer at Sturgeon Falls, Ontario, Canada  

Energy Technology Data Exchange (ETDEWEB)

The transport and partitioning of {sup 129}I has been examined for a shallow groundwater flow system at Sturgeon Falls in northeastern Ontario. Recharge into a sandy surficial postglacial deltaic aquifer occurs in the vicinity of a seasonally-wet boreal forest. Concentrations of stable iodine, {sup 129}I, tritium, radiocarbon, stable isotopes and major ions were measured on samples of groundwater and precipitation. The present-day tritium profile delineates the position of the early 1960's above-ground nuclear weapons pulse at a depth of approximately 12 m. The concentrations of stable iodine for groundwaters above, near and below the above-ground nuclear weapons pulse range from 0.07 to 1.7 ppb. Over that same interval {sup 129}I concentrations decreased from 1.9 x 10{sup 6} atoms/L at 9 m, to approximately 1.9 x 10{sup 5} atoms/L in tritium-depleted waters at 35 m, below the present-day depth of the recharging above-ground nuclear weapons peak at ...

2005-07-01

451

Uranium and thorium based phosphate matrix: synthesis, characterizations and lixiviation; Matrices a base de phosphate d'uranium et de thorium: syntheses, caracterisations et lixiviation  

Energy Technology Data Exchange (ETDEWEB)

In the framework of the search for a ceramic material usable in the radioactive waste storage, uranium and thorium phosphates have been investigated. Their experimental synthesis conditions have been entirely reviewed, they lead to the preparation of four new compounds: U(UO{sub 2})(PO{sub 4}){sub 2}, U{sub 2}O(PO{sub 4}){sub 2}, UCIPO{sub 4}, 4H{sub 2}O, and Th{sub 4}(PO{sub 4}){sub 4}P{sub 2}O{sub 7}. Experimental evidenced are advanced for non existent compounds such as: U{sub 3}(PO{sub 4}){sub 4}, U{sub 2}O{sub 3}P{sub 2}O{sub 7} and Th{sub 3} (PO{sub 4}){sub 4}. Characterization by several techniques (X-rays and neutron powder diffractions, UV-Visible and Infra-red spectroscopies, XPS,...) were performed. The ab initio structure determination of U(UO{sub 2})(PO{sub 4}){sub 2} has been achieved by X-rays and refined by neutron diffractions. Through its physico-chemical analysis, we found that this compound was a new mixed valence uranium phosphate in which ...

1995-03-01

452

Nuclear charge radii of light isotopes based on frequency comb measurements  

Energy Technology Data Exchange (ETDEWEB)

Optical frequency comb technology has been used in this work for the first time to investigate the nuclear structure of light radioactive isotopes. Therefore, three laser systems were stabilized with different techniques to accurately known optical frequencies and used in two specialized experiments. Absolute transition frequency measurements of lithium and beryllium isotopes were performed with accuracy on the order of 10{sup -10}. Such a high accuracy is required for the light elements since the nuclear volume effect has only a 10{sup -9} contribution to the total transition frequency. For beryllium, the isotope shift was determined with an accuracy that is sufficient to extract information about the proton distribution inside the nucleus. A Doppler-free two-photon spectroscopy on the stable lithium isotopes {sup 6,7}Li was performed in order to determine the absolute frequency of the 2S {yields} 3S transition. The achieved relative accuracy of 2 x 10{sup -10} is ...

2010-02-11

453

Coupled effects of the precipitation of secondary species on the mechanical behaviour and chemical degradation of concretes; Les effets couples de la precipitation d'especes secondaires sur le comportement mecanique et la degradation chimique des betons  

Energy Technology Data Exchange (ETDEWEB)

Sulfate attack of cement-based materials remains an important problem for the durability assessment of containers and disposal engineering barriers dedicated to the long-term storage of radioactive wastes since underground water which may reach these elements contains small quantities of sulfates (7-31 mmol/1). This work contributes to the study of sulfate-induced damage mechanisms, to their understanding and modelling. The experimental phases of this study aimed at the understanding of the different physico-chemical phenomena involved during an external sulfate attack at following their evolution and their impact on the transport and mechanical properties of the material. Leaching experiments in pure water and in a solution of sodium sulfate (with a sulfate content of 15 mmol/1), have been performed simultaneously on OPC paste (w/c 0,4)in order to allow a comparison of test results. The frequent analysis of the leachant has shown a consumption of sulfate ...

2002-06-01

454

C-106 tank process ventilation test  

Energy Technology Data Exchange (ETDEWEB)

Project W-320 Acceptance Test Report for tank 241-C-106, 296-C-006 Ventilation System Acceptance Test Procedure (ATP) HNF-SD-W320-012, C-106 Tank Process Ventilation Test, was an in depth test of the 296-C-006 ventilation system and ventilation support systems required to perform the sluicing of tank C-106. Systems involved included electrical, instrumentation, chiller and HVAC. Tests began at component level, moved to loop level, up to system level and finally to an integrated systems level test. One criteria was to perform the test with the least amount of risk from a radioactive contamination potential stand point. To accomplish this a temporary configuration was designed that would simulate operation of the systems, without being connected directly to the waste tank air space. This was done by blanking off ducting to the tank and connecting temporary ducting and an inlet air filter and housing to the recirculation system. This configuration would eventually ...

1998-07-20

455

[Destruction of radioactive particles by strains of Cladosporium cladosporoides (FRES.) de Vries].  

Science.gov (United States)

Reactions on the ionizing radiation of 14 Cladosporium cladosporioides strains were studied. Only 5 of them displayed radiotropizm. The ability of C. cladosporioides strains 4 and 5 with positive radiotropizm and museum C. cladosporioides strain 396 and its alb-mutant SM without positive radiotropizm to destruct radioactive particles of Chernobyl and explosion origin was studied. Two ways of radioactive particles destruction by C. cladosporioides were established, one of them is a direct way by fungal overgrowth of hot particles and the second one an indirect way only by fungal metabolites. Mycelium of the studied C. cladosporioides strains sorbed radionuclides from radioactive particles during cultivation on the liquid and agarized media. No certain inclinations of the individual strains to accumulation of radionuclides 137Cs or 152Eu were ascertained. PMID:12664550

456

The National Shipbuilding Research Program. Guide to ...  

Science.gov (United States)

... NVIC 3-94, International Maritime Organization Code for the Safe Carriage of Irradiated Nuclear Fuel, Plutonium and High-Level Radioactive ...

1997-10-01

457

Statement of work for analytical services provided by PNNL`sanalytical chemistry laboratory  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this statement of work (SOW) is to establish laboratory analytical criteria and requirements for radioactive airborne emissions measurement sample and/or analysis activities.

1997-06-30

460

Process for treatment of detergent-containing radioactive liquid wastes  

Energy Technology Data Exchange (ETDEWEB)

A detergent-containing radioactive liquid waste originating from atomic power plants is concentrated to have about 10 wt. % detergent concentration, then dried in a thin film evaporator, and converted into powder. Powdered activated carbon is added to the radioactive waste in advance to prevent the liquid waste from foaming in the evaporator by the action of surface active agents contained in the detergent. The activated carbon is added in accordance with the COD concentration of the radioactive liquid waste to be treated, and usually at a concentration 2-4 times as large as the COD concentration of the liquid waste to be treated. A powdery product having a moisture content of not more than 15 wt. % is obtained from the evaporator, and pelletized and then packed into drums to be stored for a predetermined period.

1984-02-21

461

Process for treatment of detergent-containing radioactive liquid wastes  

International Nuclear Information System (INIS)

A detergent-containing radioactive liquid waste originating from atomic power plants is concentrated to have about 10 wt. % detergent concentration, then dried in a thin film evaporator, and converted into powder. Powdered activated carbon is added to the radioactive waste in advance to prevent the liquid waste from foaming in the evaporator by the action of surface active agents contained in the detergent. The activated carbon is added in accordance with the COD concentration of the radioactive liquid waste to be treated, and usually at a concentration 2-4 times as large as the COD concentration of the liquid waste to be treated. A powdery product having a moisture content of not more than 15 wt. % is obtained from the evaporator, and pelletized and then packed into drums to be stored for a predetermined period.

1984-02-01

463

Permissibility under international law of the disposal of radioactive waste into the sub-seabed. Die voelkerrechtliche Zulaessigkeit des Verbringens radioaktiver Stoffe in den Meeresuntergrund  

Energy Technology Data Exchange (ETDEWEB)

The author investigates whether the international law regime so far has developed any legal principles dealing with the problem of the dumping of radioactive waste in the sub-seabed, and whether any of such provisions available adequately tackle the problem in the light of the gravity of danger emanating from radioactive waste. The study covers over 30 different texts of international treaties and protocols. Points of main interest are the London Dumping Convention and the Montego Bay Convention on the Law of the Sea. The author concludes that the disposal of radioactive waste into the seabed belongs to the permissible, although not specially allowed activities within the framework of the freedom of the high seas, and therefore urgently calls for establishing an international regulatory system pertaining to the planning and accomplishment of such activities. An outline legal concept of a regulatory system is explained. ...

1986-01-01

465

Nuclear waste plans enter critical phase  

Energy Technology Data Exchange (ETDEWEB)

A brief article considers the possible result of the enquiry into Nirex`s plan to build an underground rock laboratory at Sellafield in relation to radioactive waste disposal in the UK. (UK).

1996-10-31

466

Natural radioactive materials in oil and gas industry  

International Nuclear Information System (INIS)

Oil and gas production and processing operations sometimes cause naturally occurring radioactive materials (NORM) to accumulate at elevated concentrations in by-product waste streams. The sources of most of the radioactivity are isotopes of "2"3"8U and "2"3"2Th series, which are naturally present in the subsurface formations from which oil and gas are produced. NORM waste may cause problems in the operations of installations by plugging perforations, clogging tubular and valves then restricting flow. Therefore, plants or equipment have to be refurbished and decontaminated before reuse to avoid radioactive waste or surface contaminated object. There are two options for safe disposal of scale and sludge produced from NORM Descaling Facility : 1- Injection into an abandoned production well. 2- The construction of a near surface depository. These options are assumed to be environmental friendly disposal options. (author)

2010-03-01

467

Method of reducing volume of radioactive liquid waste  

International Nuclear Information System (INIS)

Purpose: To enable the solidification of liquid waste containing radioactive substance in a free shape with large volume reduction ratio without a pulverizing step by producing solute in the liquid waste as a slurry in a predetermined organic solvent and forming it into a cake by mechanical exfoliation. Method: Liquid waste containing suitably concentrated radioactive substances is supplied to a centrifugal thin film evaporator together with an organic agent having a higher boiling point than water and a non aqueous solution to evaporate the water content, the solute in the waste is produced as a slurry in the organic solvent, and removed as cake-state solute slightly residued with the organic solvent by the mechanical exfoliation such as centrifugal exfoliation or settling exfoliation from the slurry-state liquid. Accordingly, it can be increased in size as compared with the powder reduced in volume of the radioactive ...

1981-08-01

469

Development of a radon standard source  

Energy Technology Data Exchange (ETDEWEB)

The present paper describes the development of a radon standard source for use in establishing the traceability of radon concentration measurements in air. Previously, radon generated by bubbling air through a radium salt solution was widely used for calibration of radon measurement equipment; however, the handling of a solid-phase radon source is easier. In the present study, the radioactivity of radon released in a vapor phase was determined from the difference between the radioactivity of the radium and the residual radon progenies in the source. A germanium detector, calibrated using gamma reference sources, was used for these radioactivity measurements. Under equilibrium conditions the radioactivity of the radon released from the radium source was found to be 988 Bq. The source was sealed in a stainless-steel container having a nominal capacity of 6 l to produce a radon standard source of density ...

2005-06-11

470

Deposition of inhaled aerosols in beagle dogs  

International Nuclear Information System (INIS)

Additional measurements have been made of deposition and retention of inhaled radioactively labeled iron oxide aerosols generated by a spinning top aerosol generator.

1977-05-01

471

Consequences of the Chernobyl reactor accident with respect to the feeding of infants  

International Nuclear Information System (INIS)

In view of the persisting and understandable fear of parents with regard to radioactivity in the food of their babies as a consequence of the Chernobyl reactor accident, the Commission on Nutrition of the Deutsche Gesellschaft fuer Kinderheilkunde (German Society of Pediatrics) and the Strahlenschutzkommission have published a statement. According to this statement, the maximum permissible level of radioactivity in commercial baby food has been fixed by the EC to be 370 Bq/kg. The dietetic food industry itself has fixed a maximum for its products which is only a tenth of the radioactivity level permitted by the EC directive. The milk powders for infants tested since the reactor accident contained no measurable radioactivity or only very low amounts of Cs 134 or Cs 137, correspondung to a maximum of 25 Bq/kg in the product. Late damage to health is not to be expected. (orig./ECB).

472

Challenges in ensuring radiological safety and nuclear forensic for malicious acts involving nuclear and other radioactive material  

International Nuclear Information System (INIS)

Nuclear and other radioactive materials may get smuggled into the country aimed at malicious acts. Radioactive material detected accidentally or during inspection at the entry points/national borders may indicate illicit trafficking for the purpose of nuclear/radiological terrorism. As country requires prevention and preparedness for response to these malicious acts, nuclear forensic techniques are to be developed incorporating radiological safety aspects. Nuclear forensics helps in determining the origin, intended use, legal owner and the smuggled route etc. by using fingerprinting as well as comparison with reference data. The suggested sequence of methods for analysis of radioactive material/samples will be radiological assessment, physical characterization, traditional forensic analysis, isotope analysis along with elemental/chemical analysis

2010-11-15

473

A new method in the management of skin neoplasm using a flexible radioactive patch  

Energy Technology Data Exchange (ETDEWEB)

We have developed a flexible radioactive polyurethane patch incorporating {beta}-emitting radionuclide (166Ho) to treat malignant skin lesions. We covered the tumor surface (n=133) with the radioactive patch for 33.58 {+-} 5.33 minutes. Radiation dose delivered was 35 Gy for Bowen's disease (n=78), Kaposi sarcoma (n=25), actinic keratosis (n=5), and 50 Gy for BCC (n=17) and squamous carcinoma (n=8). Complete response was observed in 91.7% after the first therapeutic trial, 96.2% after 2nd and 97.7% after 4th trial with excellent cosmetic outcome for 31.15{+-}13.88 months of follow-up. Radioactive patch therapy is effective for superficial skin cancers that are impractical for surgery.

2005-07-01

474

15. Analysis of natural radioactive materials  

International Nuclear Information System (INIS)

The methods are described of determining natural radionuclides, viz., thorium, uranium, radium, radon, polonium, actinium, and protactinium. The analysis is also described of ores, rocks, minerals, water, air. (M.D.).

475

Z-dependence of photon induced L_#alpha#/L_l X-ray intensity ratio in some elements 73 #<=# Z #<=# 92  

International Nuclear Information System (INIS)

L_#alpha#/L_l X-ray intensity ratios have been measured in elements Ta, W, Au, Hg, Tl, Pb, Bi, Th and U using L-shell photoionization by 60 keV photons. The present results are found to agree with the calculated values of Scofield within experimental uncertainties. (author).

1983-11-21

476

Search for anisotropy in the L x-gamma angular correlations following the decay of "2"0"7Bi  

International Nuclear Information System (INIS)

An investigation of the Ll x-#gamma# angular correlations following the decay of "2"0"7Bi is done by using a Si(Li) semiconductor counter as L x-ray detector. Coincidence measurements at five different angles were made between the 570-keV #gamma# ray (gated in the movable counter) and the Ll x spectrum (displayed in a multichannel analyzer).

477

Radiometric measurement of lead-201 and thallium-201 activity in industrial production of thallium chlorides  

International Nuclear Information System (INIS)

The spectrometric methods and equipment for "2"0"1Pb and "2"0"1Tl activity control in the prepared thallium chloride in industrial production are described. Estimation of thallium-201 activity is carried out in accord with the square of summary photopeak caused by #gamma#-quanta at 167 keV energy. Attenuation is paid to spectrometer calibration. 5 refs.; 2 figs.; 2 tabs.

478

Radiochemistry of lead-203 for radiolabelling antibody conjugates  

International Nuclear Information System (INIS)

Lead-203 [52.1 h, 279 (80.1%) KeV] has been recognized as a potentially useful tracer for tumor specific radiopharmaceuticals due to its favorable nuclear and chemical properties. This paper reports the cyclotron production of lead-203 and the labelling of monoclonal antibody B72.3, conjugated with 2-(p-isothiocyanatobenzyl)DOTA, with lead-203 in 30% yield. In vivo biodistribution and stability studies in mice are being conducted.

1990-06-24

479

Quantitative phase imaging using hard x-rays  

International Nuclear Information System (INIS)

The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.

2009-02-01

480

Portable real time neutron spectrometry II  

International Nuclear Information System (INIS)

We describe the continued development of a portable, real-time neutron spectrometer. The spectrometer is composed of two distinct detector systems: a Helium 3 gas filled proportional counter for the lower neutron energy interval between 20 KeV and 2 MeV and a bulk silicon solid state detector for the higher energy interval between 2 MeV and 500 MeV. Modeling and experimental results with mono-energetic neutron beams are reported.

2000-01-19

481

Optical and statistical model calculation of the americium 242m capture cross section  

International Nuclear Information System (INIS)

The capture cross sections of Am 242m can be deduced from resonances analysis at low energy and computed with theoretical models at high energy. In this work, a coherent set of cross sections which reproduced the experimental values of the fission cross sections is computed. These calculations were performed for an energy of the incoming neutron between 1 keV and 1 MeV.

482

Molar extinction coefficients in aqueous solutions of some alkaline earth chlorides  

International Nuclear Information System (INIS)

Molar extinction coefficients for the solid solutes in aqueous solutions of some alkaline earth chlorides such as MgCl_2.6H_2O, CaCl_2, SrCl_2.6H_2O and BaCl_2.2H_2O have been determined at 81, 356, 511, 662, 1173 and 1332 keV energies in different concentration using the narrow beam transmission methods. (author)

1999-12-21

483

Magnetic moments of "1"7"7Ta apd sup(181,182,187)Re states  

International Nuclear Information System (INIS)

The magnetic moments of "1"7"7Ta and sup(181,182,187)Re levels decaying via the K-forbidden transitions are measured. The nuclei studied are produced via the "1"7"7W and sup(181,182)Os and "1"8"7W #beta#-decay respectively. The magnetic moments have been measured using the method of the differential #gamma##gamma# angular correlations, perturbed by an external magnetic field. The following magnetic moments and lifetimes are obtained: for the 5/2"-1/2"-[541] "1"8"1Re level with excitation energy of 357 keV #mu#/#mu#sub(n)=2.00+-0.10, Tsub(1/2)=(76+-8)x10sup(-8) s; for the 186.4 keV 5/2"-1/2"-[541] "1"7"7Ta level #mu#/#mu#sub(n)=2.02+-0.13, Tsub(1/2)=(2.78+-0.09)x10sup(-6) s; for the 236 keV 2"- "1"8"2Re level #mu#/#mu#sub(n)=2.12+-0.08; for the 203 keV 9/2"- [514] "1"8"7Re level #mu#/#mu#sub(n)=5.04+-0.09.

1978-03-01

484

Magnetic moment of the three-quasiparticle state in /sup 177/Ta  

Energy Technology Data Exchange (ETDEWEB)

An experimental investigation was made of the ..gamma..-transitions feeding or de-exciting the 1355 keV isomeric state in /sup 177/Ta. The E2/M1 mixing ratios for the 311 keV interband transition from the isomer and for the 271 keV and the 295 keV intraband transitions within the rotational band on the isomer were determined to be delta = 0.29sup(+0.11)sub(-0.06), 0.25sup(+0.05)sub(-0.03) and 0.30sup(+0.06)sub(-0.08), respectively, employing combined measurements of the linear polarization and angular distribution of the ..gamma..-ray with the aid of conversion electron measurements. Spin and parity assignments of the isomer were confirmed to be 21/2/sup -/. The half-life of the isomer was remeasured to be Tsub(1/2) = 5.0 +- 0.2 ..mu..s and the magnetic moment was found to be ..mu.. = 0.080 +- 0.014 ..mu..sub(N). The gsub(K) and gsub(R) factors for the band on the isomer were deduced separately to be ...

1982-06-07

485

Magnetic moment of the three-quasiparticle state in "1"7"7Ta  

International Nuclear Information System (INIS)

An experimental investigation was made of the #gamma#-transitions feeding or de-exciting the 1355 keV isomeric state in "1"7"7Ta. The E2/M1 mixing ratios for the 311 keV interband transition from the isomer and for the 271 keV and the 295 keV intraband transitions within the rotational band on the isomer were determined to be delta = 0.29sup(+0.11)sub(-0.06), 0.25sup(+0.05)sub(-0.03) and 0.30sup(+0.06)sub(-0.08), respectively, employing combined measurements of the linear polarization and angular distribution of the #gamma#-ray with the aid of conversion electron measurements. Spin and parity assignments of the isomer were confirmed to be 21/2"-. The half-life of the isomer was remeasured to be Tsub(1/2) = 5.0 +- 0.2 #mu#s and the magnetic moment was found to be #mu# = 0.080 +- 0.014 #mu#sub(N). The gsub(K) and gsub(R) factors for the band on the isomer were deduced separately to be gsub(K=21/2"-) = ...

486

Final Report: Planetary Instrument Definition and Design Program (PIDDP) Support Project  

Energy Technology Data Exchange (ETDEWEB)

The results of Sandia National Laboratories' participation in the NASA Planetary Definition and Design Program are summarized. Areas reported include the characterization of large area cadmium zinc telluride spectrometers and the application of simulation techniques to the prediction of device performance. Also investigated was the response of mercuric iodide devices in the region from 1 to 100 KeV. A literature study to determine the status or radiation damage measurements in room temperature semiconductor devices is also reported.

1999-03-01

487

Energy dependence of Ksub(#beta#)/Ksub(#alpha#) intensity ratio of Si0_2 from proton induced ionisation  

International Nuclear Information System (INIS)

The Ksub(#beta#)/Ksub(#alpha# 12) x-ray intensity ratio of the Si K spectrum was measured for proton impact on Si0_2 in the energy range 300-800 keV. An energy dependence of the intensity ratio was found and an explanation is given in terms of multiple ionisation. (author).

1980-04-01

488

Decay of "1"0"1Mo and band structures of its daughter nuclide "1"0"1Tc in the projected shell model  

International Nuclear Information System (INIS)

The decay of molybdenum-101 has been investigated using the three-parameter (#gamma#-#gamma#-t) coincidence system of HPGe-HPGe detectors. According to the off-line analysis, the decay scheme was modified. The positions of 221.80, 318.00, 377.90; 452.50, 515.42, 1011.05, and 1759.72 keV transitions have been arranged again, the transition positions of 104.70, 105.95, and 774.15 keV gamma rays have been assigned for the first time, the positions of 169.00, 590.91, 980.52, and 1431.68 keV transitions have been reconfirmed, and the 1508.01 keV gamma ray was observed simultaneously for the first time and its transition position has been assigned. The #beta#"- intensities and the values of log ft of most levels were calculated. Combining with the high-spin states observed by the in-beam #gamma#-ray spectroscopy of previous decay works, the structure of the excited positive/negative-parity yrast states of ...

2006-01-01

489

Complete spectroscopy of "8"7","8"8","8"9Sr with (n,#gamma#) and (d,p) reactions?  

International Nuclear Information System (INIS)

We conducted (n, #gamma#) and (d, p) reactions leading to "8"7", "8"8", "8"9"Sr in addition to "8"8Sr (d, t) "8"7Sr and 24 keV neutron capture in "8"8Sr. (orig./HSI).

490

Chemical effects on L_#gamma#_1/L_#beta#_1 x-ray intensity ratio of molybdenum compounds  

International Nuclear Information System (INIS)

Chemical effects on the intensity ratio of LX-ray of molybdenum compounds irradiated by 11-keV electrons and by 3-MeV protons were studied using an x-ray crystal spectrometer. It was found that the intensity ratios of L_#gamma#_1/L_#beta#_1 markedly decrease with the increase of ionicity of molybdenum compounds, except for the case of metallic molybdenum. (author).

1987-06-01

492

On the Metastable Level in Ni-like Ions  

Energy Technology Data Exchange (ETDEWEB)

The lowest excited level in Ni-like ions, 3d{sup 9}4s {sup 3}D{sub 3}, decays only via a magnetic octupole (M3) decay. They present calculated values of transition wavelengths and rates for ions with 30 {le} Z {le} 100. They have observed this line in Xe{sup 26+}, using the Livermore EBIT-I electron beam ion trap and a microcalorimeter, as well as a high-resolution flat-field grating spectrometer.

2004-09-14

493

Micromachining using focused ion beams  

Energy Technology Data Exchange (ETDEWEB)

Focused ion beam (FIB) systems prove to be useful precision micromachining tools for a wide variety of applications. This micromachining technique includes scanning ion microscopy (SIM), micromachining by physical sputtering, and the ion-beam induced surface chemistry for etching and deposition. This technique is applied to image and modify IC's, to micromechanical applications, to modify the tip shape of tungsten emitters, and to prepare cross sections of selected regions for inspection in a transmission electron microscope (TEM). (orig.)

1994-11-16

494

Ion-Track Membranes and Their Use in Biological and Medical Applications  

International Nuclear Information System (INIS)

This report is a brief review of biological and medical applications of ion-track membranes. The review aims at informing nuclear physicists about alternative (i.e. non-fundamental-science) use of heavy ion accelerators such as production of micro- and nano-porous materials. The ion-track membranes produced this way are employed in life sciences and numerous technological applications. The author focuses on recent results from the Flerov laboratory in co-operation with other scientific institutions and industrial partners.

2007-05-22