Evaluation of adhesive plasters by radionuclide X-ray fluorescence analysis
International Nuclear Information System (INIS)
A radiometric method was elaborated for surface density determinations of the adhesive layer of plasters by radionuclide X-ray fluorescence using the 17.47 keV bremsstrahlung of "1"4"7Pm/Mo. The bremsstrahlung line excites the 8.63 keV characteristic K#alpha# line of Zn contained in the adhesive layer of the plaster as a filling material in the form of ZnO. In homogeneous adhesive layers the Zn content is proportional to surface density. (author).
1976-01-01
Zinc determination in medicinal powders by radionuclide X-ray fluorescence analysis
International Nuclear Information System (INIS)
X-ray fluorescence analysis was used to determine the zinc content of the ''Perilacin'' powder and the ZnO content of the ''Epiderman-pix'' powder. The characteristic Ksub(#alpha#) line of zinc was excited using a "1"4"7Pm/Mo source (10"7 s"-"1) and the molybdenum Ksub(#alpha#) line (17.47 keV). 4 to 5% Zn and 45 to 49% ZnO were determined with a NaI(Tl) scintillation detector. The radiation intensity was found to decrease with particle size. (M.K.).
1977-01-01
Energy Technology Data Exchange (ETDEWEB)
The INTEGRAL/SPI spectrometer was designed to observe the sky in the energy band of 20 keV to 8 MeV. The specificity of instrument SPI rests on the excellent spectral resolution (2.3 keV with 1 MeV) of its detecting plan, composed of 19 cooled germanium crystals; covering an effective area of 508 cm{sup 2}. The use of a coded mask, located at 1.7 m above the detection plan ensures to it a resolving power of 2.5 degrees. The aim of this thesis, begun before the INTEGRAL launch, is made up of two parts. The first part relates to the analysis of the spectrometer calibration data. The objective was to measure and check the performances of the telescope, in particular to validate simulations of the INTEGRAL/SPI instrument response. This objective was successfully achieved. This analysis also highlights the presence of a significant instrumental background noise. Whereas, the second part concentrates on the ...
2005-01-15
International Nuclear Information System (INIS)
In various situations, measurements in prompt gamma neutron activation analysis (PGNAA) are performed to determine the amount of an elemental impurity relative to that of a major constituent of the matrix. An example of this is the measurement of hydrogen concentration in a metallic matrix. In all such cases, a major contributor to the uncertainty in the measurement is the uncertainty in the ratio of the high-purity germanium (HPGe) detector full-energy peak efficiency for the gamma-ray lines of interest (i.e., impurity and matrix gammas). Usually, the ratio is derived from the relative peak efficiency curve, which is determined using isotopic standards that emit multiple gamma ray lines (e.g., "1"5"2Eu) in the energy range <3000 keV, or using prompt gamma radionuclides (e.g., "1"4N, "3"5Cl) in the energy range >3000 keV. In either case, the uncertainty in the ratio of the ...
2001-06-17
Decay of "1"0"1Mo and band structures of its daughter nuclide "1"0"1Tc in the projected shell model
International Nuclear Information System (INIS)
The decay of molybdenum-101 has been investigated using the three-parameter (#gamma#-#gamma#-t) coincidence system of HPGe-HPGe detectors. According to the off-line analysis, the decay scheme was modified. The positions of 221.80, 318.00, 377.90; 452.50, 515.42, 1011.05, and 1759.72 keV transitions have been arranged again, the transition positions of 104.70, 105.95, and 774.15 keV gamma rays have been assigned for the first time, the positions of 169.00, 590.91, 980.52, and 1431.68 keV transitions have been reconfirmed, and the 1508.01 keV gamma ray was observed simultaneously for the first time and its transition position has been assigned. The #beta#"- intensities and the values of log ft of most levels were calculated. Combining with the high-spin states observed by the in-beam #gamma#-ray spectroscopy of previous decay works, the structure of the excited ...
2006-01-01
International Nuclear Information System (INIS)
Rossi X-ray Timing Explorer (RXTE) observations of the bright supernova remnant Cas A have revealed a hard power law component above 10 keV in addition to two thermal components inferred from ASCA measurements of the many line centroids from low-Z elements. The power law can be shown to be consistent with synchrotron emission from radio to hard x-rays by electrons of up to 4 x 10"1"3 eV. Measurement of the 1157 keV line by CGRO from "4"4Sc in the chain of decay of "4"4Ti predicts that the two "4"4Ti lines at 68 and 78 keV should appear at the CGRO intensity. RXTE has placed upper limits on such lines that are marginally consistent with the CGRO measurement. Implications of these results on sites for cosmic ray acceleration and nucleosynthesis are discussed.
1999-01-01
Accretion Properties of A Sample of Hard X-ray (<60keV) Selected Seyfert 1 Galaxies
We examine the accretion properties in a sample of 42 hard (3-60keV) X-ray selected nearby broad-line AGNs. The energy range in the sample is harder than that usually used in the similar previous studies. These AGNs are mainly complied from the RXTE All Sky Survey (XSS), and complemented by the released INTEGRAL AGN catalog. The black hole masses, bolometric luminosities of AGN, and Eddington ratios are derived from their optical spectra in terms of the broad H$\\beta$ emission line. The tight correlation between the hard X-ray (3-20keV) and bolometric/line luminosity is well identified in our sample. Also identified is a strong inverse Baldwin relationship of the H$\\beta$ emission line. In addition, all these hard X-ray AGNs are biased toward luminous objects with high Eddington ratio (mostly between 0.01 to 0.1) and low column density ($<10^{22} ...
2008-01-01
The differential cross section measurements for /sup 241/Am, /sup 242m/Am and /sup 243/Am are reviewed in the energy range from 0.5 eV to 10 keV. Parameters extracted from resonance analysis, such as the neutron strength function, the average level spacing, the average capture and fission widths, are compared for the various measurements. The average capture and fission cross sections from 100 eV to 10 keV are directly compared. The status of the data set is discussed with suggestions for further measurements. 24 references.
1978-11-16
We present a detailed spectral analysis of point-like X-ray sources in the XMM-COSMOS field. Our sample of 135 sources only includes those that have more than 100 net counts in the 0.3-10 keV energy band and have been identified through optical spectroscopy. The majority of the sources are well described by a simple power-law model with either no absorption (76%) or a significant intrinsic, absorbing column (20%).As expected, the distribution of intrinsic absorbing column densities is markedly different between AGN with or without broad optical emission lines. We find within our sample four Type-2 QSOs candidates (L_X > 10^44 erg/s, N_H > 10^22 cm^-2), with a spectral energy distribution well reproduced by a composite Seyfert-2 spectrum, that demonstrates the strength of the wide field XMM/COSMOS survey to detect these rare and underrepresented sources.
2006-01-01
Investigation of natural radionuclides in selected NORM-samples
International Nuclear Information System (INIS)
A programme has been initiated by the Coordinating Office for Monitoring of enhanced natural radioactivity of the Federal Office for Radiation Protection to investigate different kinds of sample materials with enhanced naturally occurring radioactivity (NORM) such as scales from oilfield and naturally gasfield pipes, blast furnace sludge and sinter dust from the production of pig iron, as well as bauxit and red mud from the production of aluminium oxide. The aim of these investigations is to find proper preparation and measuring methods which allow, in particular, a sample treatment with optimised effort combined with a reliable determination of the specific activities of the dominating radionuclides. Of particular interest is the method of gamma-ray spectrometry, since this method has been used for most of our studies of sample materials. Due to different compositions of calibration and NORM-samples, e.g. different densities, and the analysis of low-energy ...
2005-09-20
High resolution alpha-particle spectroscopy using CR-39 plastic track detector
Energy Technology Data Exchange (ETDEWEB)
A technique has been developed for high resolution alpha particle spectroscopy from track length determination in CR-39 plastic. On individual tracks an energy resolution deltaE close to the range straggling limit is obtainable. For 6 MeV alpha-particle deltaE is proportional 35 keV on individual particles and for groups of particles deltaE proportional 20 keV can be achieved using certain data selection criteria. At 100 keV on individual particles deltaE is proportional 20 keV. The analysis requires 1) a knowledge of the track-etch rate (Vsub(T))-range relationship and 2) a theoretical understanding of alpha-particle track structure in CR-39 as a function of particle energy, dip angle and degree of etching. The structure of alpha-particle etched tracks in CR-39 is described and two methods of analysis discussed. Examples are given of the resolution attainable ...
1984-06-15
Thermal and Electromigration-Induced Strains in Polycrystalline Films and Conductor Lines
2006-01-01
Microprobe RBS analysis of localized processed areas by FIB etching and deposition
International Nuclear Information System (INIS)
Localized beam-processed areas using chemical reactions induced by a 30 keV Ga"+ focused ion beam (FIB) with and without I_2 (etching) and (CH_3)_3CH_3C_5H_5Pt gases (Pt deposition) have been analyzed using a 300 keV Be"2"+ microprobe with a beam spot size of 50-80 nm. The analyzed results have been compared with energy dispersive X-ray (EDX) analysis using an electron beam. The EDX analysis only indicated incorporated impurities at high fluence such as Ga, Pt and C, while microprobe RBS analysis could detect residual iodine with low concentration which couldn't be detected by EDS analysis because of the lower sensitivity of the EDX analysis for heavy atoms.
2001-07-01
Focused ion beam processes for high-T/sub c/ superconductors
International Nuclear Information System (INIS)
Focused ion beam (FIB) processes have been developed for Y--Ba--Cu--O superconductor films. A Y--Cu liquid metal ion source has been fabricated, using a Y_6_7 --Cu_3_3 eutectic alloy as the ion source. As-sputtered Y--Ba--Cu--O film etch rate ratios to GaAs(100) and Si(100) substrates are 0.28 and 1.4 for 130-keV Au"+ FIB ion etching, respectively. Y--Ba--Cu--O submicron patterns have been demonstrated by using FIB lithography and Cl_2 reactive ion beam etching. Moreover, a Y--Ba--Cu--O superconducting line with 4-#mu#m linewidth has been fabricated by annealing an as-sputtered Y--Ba--Cu--O line pattern. T/sub c/ control of Y--Ba--Cu--O film has been achieved by 200-keV Ne"+, using conventional ion implantation and 300 keV Si"+"+ FIB ion implantation.
Intensity of auger-emission of silicon from binary compounds in the ion auger spectroscopy
International Nuclear Information System (INIS)
Auger-electron emission from different silicides has been studied for 4 and 10 keV Ar ion excitation. The intensity of the SiLMM Auger line changes significantly with channing concentration and atomic number of the metal-parthner. The experimental results can be explained in terms of a simple model based on the probability of Si-Si collision symmetric cascade in these binary compounds.
The JT-60U 2.45 MeV neutron time-of-flight spectrometer
Energy Technology Data Exchange (ETDEWEB)
A 2.45 MeV neutron time-of-flight spectrometer was designed and built for measurements of neutron energy spectra from the JT-60U Tokamak. The spectrometer consists of two fast plastic scintillators (50 cm{sup 2} and 1800 cm{sup 2}, thickness: 2 cm) where each detector is located on two constant time-of-flight spheres. The time-of-flight spheres have radius of 1 m which gives a neutron flight length of {approx}164 cm and a time-of-flight of {approx}92 ns for 2.45 MeV source neutrons. The calculated spectrometer efficiency and resolution are 2.8 x 10{sup -2} cm{sup 2} and 105 keV (4.3%), respectively. The energy resolution corresponds to a time resolution of 2.0 ns. The spectrometer will measure neutrons in a vertical line-of-sight, {approx}9 m from the plasma center. For a total neutron emission of 10{sup 16} n/s, the countrate in the first scattering detector, located in the neutron beam, is estimated to {approx}2.5 MHz. The useful countrate ...
1999-11-01
Microfabrication processes for high-T_c superconducting films
International Nuclear Information System (INIS)
Microfabrication processes for Y-Ba-Cu-O films have been investigated, using ion-beam techniques. High-T_c superconducting lines as narrow as 0.8 #mu#m have been fabricated from epitaxial YBa_2Cu_3O_7 _- _y films by Ar ion-beam etching (IBE), combined with focused ion-beam (FIB) lithography. The resulting lines, 1.3 #mu#m wide and 2 mm long, showed a zero resistance temperature of 81 K and a critical current density of 1.9 x 10"4 A/cm"2 at 77.3 K. Maskless etching was carried out using 130-keV au"+ focused ion-beam (FIB) with a 0.1-#mu#m-diameter beam. A 50-nm-thick film was patterned into 0.3-#mu#m-wide lines at a dose of 5 x "1"6 ions/cm"2. In comparison with Ar IBE, Cl_2 reactive ion-beam etching (RIBE) exhibited an enhancement effect in sputtering yield. Ion implantation with 300-keV Si"+ "+ FIB also indicated the possibility to produce submicrometer patterns by selectively ...
International Nuclear Information System (INIS)
A 20-MeV proton accelerator is developed by Proton Engineering Frontier Project (PEFP) at Korea Atomic Energy Research Institute (KAERI). The 20MeV accelerator consists of 50keV proton injector, 3MeV RFQ (Radio frequency Quadrupole), 20MeV DTL (Drift Tube Linac) and 20MeV beam line. The beam profile was measured at the end of the 20MeV beam line with wire scanner. Moreover the beam emittance was calculated from the quad scan method using beam line quadrupole magnets. In this paper, the beam profile measurement results are presented and the emittance measurement from the quad scan method is discussed
2010-10-01
Parity nonconservation in "2"0"7Pb
International Nuclear Information System (INIS)
Two experiments are currently underway to measure the single-particle weak mixing matrix element for the 1064 KeV transition in "2"0"7Pb. One experiment measures the circular polarization of the 1064 KeV gamma ray emitted from an unpolarized source, while the other experiment measures the forward-backward asymmetry of gamma rays emitted from a polarized source. Analysis of the first set of polarized source data yields an upper limit of 46 eV for the single-particle weak mixing matrix element. copyright 1995 American Institute of Physics.
Energy Technology Data Exchange (ETDEWEB)
In this work, the chemical transformations induced by 5 keV protons (10{sup 6} ion cm{sup -2}) at the surface of 0.4 {mu}m polyacrylonitrile and polymethacrylonitrile films are analysed by XPS and IRRAS. Spectroscopic changes in both the polymers are globally similar, the most significant feature being a lower relative concentration of nitrogen with respect to carbon closer to the surface. Quantitatively, this change is more marked in the case of polyacrylonitrile which suggests a direct relation with the hydrogen in {alpha} to the nitrile function.
1999-05-02
Energy Technology Data Exchange (ETDEWEB)
The energy dispersive beamline X6A at the National Synchrotron Light Source employs a curved crystal monochromator (polychromator) which focuses a range ([similar to]1 keV) of x-ray energies into a narrow (100--120 [mu]m) line image. Although this beamline was constructed primarily for time-dependent EXAFS experiments, we have begun to explore the use of this instrument for energy dispersive diffraction experiments with different types of sample including macromolecular crystals. The tunability ([ital E]=6.5 to 21 keV) and flexibility ([Delta][ital E]=100--1000 eV) of the instrument makes the beamline ideal as a test bed for the application of polychromatic single-crystal diffraction techniques to different chemical or biological materials.
1995-02-01
International Nuclear Information System (INIS)
The absolute cross sections of "2"3Na(p,n)"2"3Mg, "2"7Al(p,n)"2"7Si and "3"0Si(#alpha#,n)"3"3S reactions were measured in the incident energy range of 5.05 to 5.80, 5.80 to 6.25 and 3.975 to 6.235 MeV respectively using a spherically shaped 4#pi# neutron detector. In the energy range 5.80 to 7.80 and 6.235 to 11.30 MeV the absolute cross sections of "2"3Na(p,n)"2"3Mg and "3"0Si-(#alpha#,n)"3"3S reactions were determined by optical model calculations. The cross sections of the inverse reactions "2"3Mg(n,p)"2"3Na and "3"3S(n,#alpha#)"3"0Si were also calculated by the same method for the neutron energy range of 10 keV to 7.50 MeV for each reaction. The cross section of the latter reaction in the neutron energy range of 10 keV to 840 keV was also determined from its inverse reaction "3"0Si(#alpha#,n)"3"3S by the application of the detailed balance theorem. The reactions for which the cross sections were determined are of ...
Nuclear structure studies via neutron interactions
Energy Technology Data Exchange (ETDEWEB)
Research preformed consisted of: (1) publication of an experimental paper for the n + {sup 40}Ar high resolution total cross section and submission of a theoretical paper dealing with the prediction of the average parameters deduced from the the data; (2) preliminary R-matrix analysis of the neutron total cross section data for the n + {sup 208}Pb systems, up to an energy of 1.7 MeV; (3) completed the analysis of neutron total cross section of data for n + {sup 54}Fe up to energy of 500 keV, with j{sup {pi}} values confirmed, in most cases, by differential scattering data; (4) analysis of total cross section data for the n + {sup 88}Sr system up to an energy of 175 keV; (5) development of a graphical interface for the code RFUNC, used to calculate the differential scattering cross sections, for comparison with measurements.
1991-03-01
Focused ion beam damage to MOS integrated circuits
Energy Technology Data Exchange (ETDEWEB)
Commercial focused ion beam (FIB) systems are commonly used to image integrated circuits (ICS) after device processing, especially in failure analysis applications. FIB systems are also often employed to repair faults in metal lines for otherwise functioning ICS, and are being evaluated for applications in film deposition and nanofabrication. A problem that is often seen in FIB imaging and repair is that ICS can be damaged during the exposure process. This can result in degraded response or out-right circuit failure. Because FIB processes typically require the surface of an IC to be exposed to an intense beam of 30--50 keV Ga{sup +} ions, both charging and secondary radiation damage are potential concerns. In previous studies, both types of effects have been suggested as possible causes of device degradation, depending on the type of device examined and/or the bias conditions. Understanding the causes of this damage is ...
2000-05-10
Observation of a surface peak in low energy implant depth profiles in silicon
Energy Technology Data Exchange (ETDEWEB)
In situ Auger sputter depth profiles of saturation implants of 3 keV N/sub 2//sup +/ in silicon at room temperature exhibit a sharp peak in the nitrogen concentration in the outermost layers, followed by a monotonic decrease. No broad plateau was observed. The energy of the Auger line corresponding to the Si(2p) core electron excitation, monitored throughout the profiling, exhibits a chemical shift of up to 7 eV at the surface peak concentration. Inert gas ion post-bombardment of unsaturated implants significantly modifies the profile, and supports the suggestion that the surface peak arises through radiation enhanced diffusion of implanted atoms.
1984-03-01
An Apparent Hard X-ray Decline of CH Cygni
CH Cygni is a symbiotic star consisting of an M giant and an accreting white dwarf, which is known to be a highly variable X-ray source with a complex, two-component, spectra. Here we report on two Suzaku observations of CH Cyg, taken in 2006 January and May, during which the system was seen to be in a soft X-ray bright, hard X-ray faint state. Based on the extraordinary strength of the 6.4 keV fluorescent Fe K-alpha line, we show that the hard X-rays observed with Suzaku are dominated by scattering.
2006-01-01
Focused ion beam preparation of inclined planes in semiconductor materials
International Nuclear Information System (INIS)
Focused ion beam (FIB) micromachining has been used to produce inclined planes on semiconductor surfaces. A 10 keV FIB system, utilising a Ga"+ liquid metal ion source (LMIS), was employed. The ramped surfaces were prepared by digitally deflecting the ion beam in a serpentine fashion over a rectangular area and incrementing the time the beam spends at a pixel, dwell time, line by line. For the conditions used, control in micromachining the inclination of the ramps to the starting horizontal surface is of the order of 1 arc s per scan of the FIB over the area of interest. The possibility of using such surfaces prepared by FIB, along with vacuum growth techniques such as molecular beam epitaxy (MBE), for application to strain relief structures and lateral device production is discussed. (author).
Photodetachment of negative ion beams in the presence of a background gas
Energy Technology Data Exchange (ETDEWEB)
To suppress space charge blowup in an ion beam passing through a photoneutralizer, it is necessary to introduce some background gas. An analysis is presented of the neutralization of a high-energy, >200-keV negative deuterium ion beam, exposed to photodetachment while in the presence of deuterium. With a gas thickness of <0.01 Torr.cm, the neutral fraction in the output beam is found to be about the same as that gotten from the photoneutralizer operating in vacuum. Neutral atom beam injection for plasma heating is discussed.
1987-03-01
Optical and statistical model calculation of the americium 242m capture cross section
International Nuclear Information System (INIS)
The capture cross sections of Am 242m can be deduced from resonances analysis at low energy and computed with theoretical models at high energy. In this work, a coherent set of cross sections which reproduced the experimental values of the fission cross sections is computed. These calculations were performed for an energy of the incoming neutron between 1 keV and 1 MeV.
International Nuclear Information System (INIS)
The flight line profile data and statistical analysis results for the Port Alexander Quadrangle in southeast Alaska are presented.
COMPARING CONSIDER-COVARIANCE ANALYSIS WITH SIGMA-POINT CONSIDER ...
As presented in [4], the Sigma-Point Consider Filter (SPCF) algorithm extends ... lines of the derivative-free, Sigma-Point Kalman Filter algorithm given in ...
International Nuclear Information System (INIS)
An ytterbium-169 high dose rate brachytherapy source, distinguished by an intensity-weighted average photon energy of 92.7 keV and a 32.015#+-#0.009 day half-life, is characterized in terms of the updated AAPM Task Group Report No. 43 specifications using the MCNP5 Monte Carlo computer code. In accordance with these specifications, the investigation included Monte Carlo simulations both in water and air with the in-air photon spectrum filtered to remove low-energy photons below 10 keV. TG-43 dosimetric data including S_K, D(r,#theta#), #LAMBDA#, g_L(r), F(r,#theta#), #phi#_a_n(r), and #phi#_a_n were calculated and statistical uncertainties in these parameters were derived and calculated in the appendix.
2006-01-01
Abundances of s-process elements in planetary nebulae: Br, Kr & Xe
We identify emission lines of post-iron peak elements in very high signal-to-noise spectra of a sample of planetary nebulae. Analysis of lines from ions of Kr and Xe reveals enhancements in most of the PNe, in agreement with the theories of s-process in AGB star. Surprisingly, we did not detect lines from Br even though s-process calculations indicate that it should be produced with Kr at detectable levels.
2006-01-01
Comparison of beam-induced deposition using ion microprobe
International Nuclear Information System (INIS)
The localized Pt deposition on Si by 30 keV Ga"+ focused ion beam (FIB), 10 keV electron beam (EB) or dual beams (FIB and EB) using precursor gas has been compared by analysis using a 300 keV Be"2"+ microprobe with a beam spot size of 80 nm. The distribution of deposited Pt, Ga from the ion beam itself, and C from the precursor gas was obtained at and nearby the deposited areas by micro-RBS spectra and RBS mapping. All of the beam processed areas showed a uniform Pt distribution at the deposited areas. The amount of Pt atoms increased with the increase in ion or electron dose due to the decomposition of precursor gas. The thickness of Pt layer by EB is considerably less than that by FIB due to the reduced deposition rate. Ga atoms from the center of processed areas partly redeposited at and nearby the FIB processed areas within #approx#3 #mu#m. The Ga incorporation by dual beam processing was reduced ...
1999-01-02
X-ray production with sub-picosecond laser pulses
Energy Technology Data Exchange (ETDEWEB)
The interaction of intense, sub-picosecond laser pulses with solid targets produces intense picosecond x-ray pulses. With focused laser pulses of several 10 {sup 18} W/cm{sup 2}, He-like and H-like line radiation from targets such as aluminum and silicon has been produced. The energy conversion efficiency from the laser pulse energy to the 1--2 keV line x-rays is nearly one percent. The duration of the line x-ray radiation is of the order of ten picoseconds, although this may be an upper estimate because of the temporal resolution of the x-ray streak camera. The spatial extent of the x-ray source region is only slightly larger than the laser focal spot, or about 10 {mu}m in diameter. With these characteristics, such x-ray sources emit an intensity of nearly 10{sup 14} W/cm{sup 2}. Experiments and modeling which led to the above conclusions will be discussed.
1993-12-31
Suzaku and Optical Spectroscopic Observations of SS 433 in the 2006 April Multiwavelength Campaign
We report results of the 2006 April multi-wavelengths campaign of SS 433, focusing on X-ray data observed with Suzaku at two orbital phases (in- and out-of- eclipse) and simultaneous optical spectroscopic observations. By analyzing the Fe25 K_alpha lines originating from the jets, we detect rapid variability of the Doppler shifts, dz/dt ~ 0.019/0.33 day^-1, which is larger than those expected from the precession and/or nodding motion. This phenomenon probably corresponding to "jitter" motions observed for the first time in X-rays, for which significant variability both in the jet angle and intrinsic speed is required. From the time lag of optical Doppler curves from those of X-rays, we estimate the distance of the optical jets from the base to be ~(3-4) \\times 10^14 cm. Based on the radiatively cooling jet model, we determine the innermost temperature of the jets to be T_0 = 13 +/- 2 keV and 16 +/- 3 keV (the average of ...
2010-01-01
International Nuclear Information System (INIS)
These experiments were performed on the Isocele separator, on-line with the Orsay synchrocyclotron; thulium isotopes were produced by bombarding natural erbium targets with 150nA beam of 157MeV protons. Two Ge(Li) detectors, with resolution of 2.3 and 2.5keV at 1332keV used for #gamma#-ray measurements; conversion electron spectra were measured using a Si(Li) detector. #gamma# spectra, #gamma#-#gamma# coincidence and conversion electron measurements were sufficient to build the flow energy level schemes of the transitional "1"5"8Er and "1"5"6Er nuclei. On both nuclei several quasi rotational bands have been identified. These results are compared with other even erbium isotopes and with the neighboring N=88 and 90 isotones. Comparisons with predictions issued from some classical models are also performed: "1"5"8Er appears as a deformed nucleus very similar to "1"6"0Er and "1"6"2Er; on the other hand "1"5"6Er seems to be a ...
1976-01-01
Energy Technology Data Exchange (ETDEWEB)
The conceptual design, parametric analysis, cost and performance analysis, and commercial assessment of a 100-MWe line-focus solar central receiver power plant are reported. This volume contains the appendices: (a) methods of determination of molten salt heat-transfer coefficients and tube-wall temperatures, (b) inputs for STEAEC programs, (c) description of system analysis computer program, (d) receiver analysis program, and (e) heliostat production plan and design methodology. (WHK)
1980-04-01
Microfabrication processes for high-T sub c superconducting films
Energy Technology Data Exchange (ETDEWEB)
Microfabrication processes for Y-Ba-Cu-O films have been investigated, using ion-beam techniques. High-{Tc} superconducting lines as narrow as 0.8 {mu}m have been fabricated from epitaxial YBa{sub 2}Cu{sub 3}O{sub 7 {minus} {ital y}} films by Ar ion-beam etching (IBE), combined with focused ion-beam (FIB) lithography. The resulting lines, 1.3 {mu}m wide and 2 mm long, showed a zero resistance temperature of 81 K and a critical current density of 1.9 {times} 10{sup 4} A/cm{sup 2} at 77.3 K. Maskless etching was carried out using 130-keV au{sup +} focused ion-beam (FIB) with a 0.1-{mu}m-diameter beam. A 50-nm-thick film was patterned into 0.3-{mu}m-wide lines at a dose of 5 {times} {sup 16} ions/cm{sup 2}. In comparison with Ar IBE, Cl{sub 2} reactive ion-beam etching (RIBE) exhibited an enhancement effect in sputtering yield. Ion implantation with 300-keV Si{sup + +} FIB also ...
1989-12-01
Construction, testing of the 1 MW, 130-260 GHz Fusion-FEM
Energy Technology Data Exchange (ETDEWEB)
During the previous 9 months the major part of the Fusion-FEM has been constructed. The 2 MV Insulated Core Transformer, the electron gun, the accelerator, the focusing lenses and the undulator have been tested on-site. In the present - temporary - set-up, the electron beam line consists of a 12 A, 80 keV thermionic electron gun, a 2 MeV dc accelerator, beam transport optics, the undulator and a collector. The gun is mounted in the high voltage terminal, which is now at -2 MV, and the undulator and mm-wave system am at ground potential outside the SF{sub 6}-filled pressure tank. This so-called inverse set-up allows easy access to the larger part of the beam line, the undulator and the mm-wave system, which is important in the conditioning phase. The decelerator and depressed collector am not yet installed. The design of the electron beam line has been optimised using the GPS particle-tracking code and ...
1995-12-31
Transient overvoltages and overcurrents during line fault tests on the Hokkaido-Honshu HVDC line
Energy Technology Data Exchange (ETDEWEB)
A series of line fault tests have been conducted at completion of Stage I of the Hokkaido-Honshu HVDC Link of Electric Power Development Co., Ltd., prior to its commercial operation, in order to study transient overvoltages and overcurrents and to confirm safety operation of system protecting devices in case of DC transmission line faults. The Hokkaido-Honshu HVDC Link is a metallic return HVDC overhead line and cable transmission system, currently being a monopolar system. For this, measurements were conducted this time on reverse polarity overvoltages occurring on main line cable, return line overvoltages, fault arc dynamic characteristics, and DC bypass current through the AC system. The results obtained were then compared with the analysis results by the HVDC surge similator or digital simulation conducted for system design prior to the field tests. As a ...
1982-08-01
The Mid-Infrared Narrow Line Baldwin Effect Revealed by Spitzer
We present our discovery of a narrow-line Baldwin effect, an anti-correlation between the equivalent width (EW) of a line and the flux of the associated continuum, in 5-20$\\mu$m mid-infared lines from a sample of 68 Active Galactic Nuclei (AGN), located at z$<$0.5, observed with the Infrared Spectrograph on the {\\it Spitzer Space Telescope}. Our analysis reveals a clear anti-correlation between the EW of the [SIV] 10.51$\\mu$m, [NeII] 12.81$\\mu$m, and [NeIII] 15.56$\\mu$m lines and their mid-IR continuum luminosities, while the Baldwin effect for [NeV] 14.32$\\mu$m is not as obvious. We suggest that this anti-correlation is driven by the central AGN and not circumnuclear star formation in the host galaxy. We also find that the slope of the narrow-line Baldwin effect in the mid-infrared does not appear to steepen with increasing ionization potential. ...
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this paper is to present an analysis of lightning fault detection, location and protection using numeric distance relays applied in high voltage transmission lines, more specifically in the 500 kV transmission lines of CEMIG (Brazilian Energy Utility) between the Vespasiano 2 - Neves 1 (short line - 23.9 km) and Vespasiano 2 - Mesquita (long line - 148.6 km) substations. The analysis was based on the simulations results of numeric distance protective relays on power transmission lines, realized in September 02 to 06, 2002, at Siemens AG's facilities (Erlangen - Germany), using Real Time Digital Simulator (RTDS{sup TM}). Several lightning faults simulations were accomplished, in several conditions of the electrical power system where the protective relays would be installed. The results are presented not only with the ...
2007-07-01
Fourier analysis of energy transfer data obtained by simulating a 14-MeV #alpha#-particle in water
International Nuclear Information System (INIS)
Data from Monte Carlo transport codes are used to model radiobiological effects. We previously reported the Fourier analysis of ionization data generated by simulating a 500-keV proton traversing water. Here, we extend Fourier analysis to energy transfer data of another radiation type, a 14-MeV #alpha#-particle. A radiobiological model based on this frequency-domain analysis views cell as an information processing system . It lends itself naturally to traditional engineering analyses. One engineering principle-the output response of a linear system to random signal-is applied here to explain the fact that there is measurable difference in the magnitude of the biological effectiveness when a given biological system is irradiated with two different radiation types of the same Linear Energy Transfer (LET).
2010-01-15
VLF wave stimulation by pulsed electron beams injected from the space shuttle
International Nuclear Information System (INIS)
Among the investigations conducted on the space shuttle flight STS 3 March 1982 was an experiment in which a 1-keV, 100-mA electron gun was pulsed at 3.25 and 4.87 kHz. The resultant waves were measured with a broadband plasma wave receiver. At the time of flight the experimental setup was unique in that the electron beam was square wave modulated and that the shuttle offered relatively long times for in situ measurements of the ionospheric plasma response to the VLF pulsing sequences. In addition to electromagnetic response at the pulsing frequencies the waves exhibited various spectral harmonics as well as the unexpected occurrence of satellite lines around those harmonics. Both phenomena occurred with a variety of different characteristics for different pulsing sequences.
Resonant neutralization of He ions into excited states at Cu(110) and Ni(110) surfaces
Energy Technology Data Exchange (ETDEWEB)
He ions incident at grazing angles on Cu(110) and Ni(110) surfaces are neutralised into triplet and singlet states, of which the 3p, 3d and 4d upper states are accessible to optical spectroscopy. In the energy range from 500 eV to 15 keV no significant energy dependence of the relative intensities of singlet and triplet lines was observed for scattering on Cu(110). The intensities from Ni(110) are higher and the singlet to triplet intensity ratio of the 3d to 2p transition is about 6% smaller than that from Cu(110). The results can be explained well by assuming resonant charge capture into excited He and intermediate formation of negative He/sup -/ states.
1984-03-01
Resonant neutralization of He ions into excited states at Cu(110) and Ni(110) surfaces
International Nuclear Information System (INIS)
He ions incident at grazing angles on Cu(110) and Ni(110) surfaces are neutralised into triplet and singlet states, of which the 3p, 3d and 4d upper states are accessible to optical spectroscopy. In the energy range from 500 eV to 15 keV no significant energy dependence of the relative intensities of singlet and triplet lines was observed for scattering on Cu(110). The intensities from Ni(110) are higher and the singlet to triplet intensity ratio of the 3d to 2p transition is about 6% smaller than that from Cu(110). The results can be explained well by assuming resonant charge capture into excited He and intermediate formation of negative He"- states. (orig.).
1983-07-01
Infrared monitoring of the Doublet III beam armor plate
Energy Technology Data Exchange (ETDEWEB)
An 80 keV, 3.6 MW neutral beam injection system has recently been installed on Doublet III, and the installation of a second system is scheduled within several months. Armor plate consisting of /approximately equals/100 graphite tiles (10 cm x 10 cm) coated with TiC has been plated over portions of the inner vacuum wall lying in the line of sight of the ion sources. In order to monitor the condition of the armor plate an infrared camera and a set of optical pyrometers have been installed alongside the beamline and view the armor plate through a CaF/sub 2/ window. The pyrometers measure the temperature of the armor plate associated with the maximum of the intensity distribution of each ion source.
1981-01-01
Resonant overvoltage phenomena caused by transmission line faults
Energy Technology Data Exchange (ETDEWEB)
Resonant overvoltages in EHV transformers can be initiated by transmission line faults. A series of field tests were performed on the 151 mile long Kammer-Marysville 765 kV line in which a sequence of single line to ground faults were applied to one outside phase at 4 different locations. Fault location criteria and fault initiation procedures are presented. Oscillograms recorded the 3 phase response at both terminals of the line; one is transformer terminated, the other is open-ended. A frequency spectrum analysis of the waveforms is provided showing transient frequencies of sufficient magnitude and duration near the EHV transformer's resonant frequency to stimulate internal winding resonant overvoltages. Digital computer studies are presented and agree with the field tests quite favorably.
1985-09-01
Microstructure analysis of nanocrystalline powders by X-ray diffraction
International Nuclear Information System (INIS)
The use of X-ray diffraction line profile analysis for the study of nanocrystalline powders is described. The fundamentals of the theory are presented in terms of crystallite/domain size, size distribution, lattice distortion, dislocations density and stacking faults. Line profile parameters and the methods of pattern fitting introduced to overcome the diffraction-line overlap problem are discussed. The approaches based of the integral breadth of the measured line profiles and the Fourier method are discussed. In addition, simplified approaches are also commented. Representative examples are selected to illustrate various cases of microstructure, such as nanomaterials with strain-free spherical nano crystallites, strain-free crystallites with anisotropic crystallite shape, anisotropic crystallites with microstrains and spherical crystallites with dislocation densities and ...
2001-09-23
A novel CFD/structural analysis of a cross parachute
Energy Technology Data Exchange (ETDEWEB)
A novel CFD/structural analysis was performed to predict functionality of a cross parachute under loadings near the structural limits of the parachute. The determination of parachute functionality was based on the computed structural integrity of the canopy and suspension lines. In addition to the standard aerodynamic pressure loading on the canopy, the structural analysis considered the reduction in fabric strength due to the computed aerodynamic heating. The intent was to illustrate the feasibility of such an analysis with the commercially available software PATRAN.
1993-12-31
Energy Technology Data Exchange (ETDEWEB)
The conceptual design, parametric analysis, cost and performance analysis, and a commercial assessment of a 100-MWe high-temperature line-focus central power system are presented. Parametric analyses and conceptual design of the heliostat subsystem, receiver subsystem, heat transport subsystem, energy storage subsystem, electrical power generating subsystem, and master control subsystem are included. A market analysis and development plan are given. (WHK)
1980-04-01
PROBING THE ORIGINS OF THE C IV AND Fe K? BALDWIN EFFECTS
International Nuclear Information System (INIS)
We use UV/optical and X-ray observations of 272 radio-quiet Type 1 active galactic nuclei and quasars to investigate the C IV Baldwin Effect (BEff). The UV/optical spectra are drawn from the Hubble Space Telescope, International Ultraviolet Explorer and Sloan Digital Sky Survey archives. The X-ray spectra are from the Chandra and XMM-Newton archives. We apply correlation and partial-correlation analyses to the equivalent widths (EWs), continuum monochromatic luminosities, and ?ox, which characterizes the relative X-ray to UV brightness. The EW of the C IV ?1549 emission line is correlated with both ?ox and luminosity. We find that by regressing l?(2500 A) with EW(C IV) and ?ox, we can obtain tighter correlations than by regressing l?(2500 A) with only EW(C IV). Both correlation and regression analyses imply that l?(2500 A) is not the only factor controlling the changes of EW(C IV); ?ox (or, equivalently, the soft X-ray emission) plays a fundamental role in the ...
2009-09-01
Possibility of internal transport barrier formation and electric field bifurcation in LHD plasma
Energy Technology Data Exchange (ETDEWEB)
Theoretical analysis of the electric field bifurcation is made for the LHD plasma. For given shapes of plasma profiles, a region of bifurcation is obtained in a space of the plasma parameters. In this region of plasma parameters, the electric field domain interface is predicted to appear in the plasma column. The reduction of turbulent transport is expected to occur in the vicinity of the interface, inducing a internal transport barrier. Within this simple model, the plasma with internal barriers is predicted to be realized for the parameters of T{sub e}(0) {approx} 2 keV and n(0) {approx_equal} 10{sup 18} m{sup -3}. (author)
1999-05-01
Nondestructive analysis for "2"3"2U and decay progeny in animal tissues
International Nuclear Information System (INIS)
Direct determination of "2"3"2U and its decay products in animal tissues appears to be feasible using an intrinsic Ge(Li) diode detector (for energies of 5-100 keV) and a NaI(Tl) anticoincidence-shielded Ge(Li) diode for higher-energy gamma photons. The detection sensitivity for "2"3"2U and "2"2"8Th is 0.03 and 0.01 nCi, respectively, using a 300-min counting time.
1977-05-01
Delayed neutron energy spectra following fast fission of "2"3"8U
International Nuclear Information System (INIS)
Delayed neutron energy spectra have been measured for six delay-time intervals following the fast fission of "2"3"8U nuclei. The delay-time intervals span the range 0.17 to 10.2 seconds following initial fission while the measured spectra span neutron energies from 10 keV to 4 MeV. The experiment was performed utilizing the UMass/Lowell 5.5 MV Van de Graff accelerator to produce fast neutrons for inducing fission in a "2"3"8U lined fission chamber. The fission fragments were flushed via a helium jet stream to a well-shielded counting room where they were deposited onto a moving tape (magnetic audio tape) and transferred to a beta-neutron time-of-flight spectrometer. By adjusting the tape speed, composite delayed neutron time-of-flight spectra were measured for several different delay-time intervals. These measurements involved beta-neutron coincidences with "6Li-loaded glass scintillators for neutron energies from 10 keV to ...
Electric field exposure from electric blankets
Energy Technology Data Exchange (ETDEWEB)
Comparisons of the 60 Hz electric field exposures associated with high voltage transmission lines to those associated with common household sources can provide an important input to regulatory decisions that involve transmission line fields. Electric blankets are of interest in this context because the exposures they produce are among the most intense and prolonged of any of the household sources of 60 Hz electric field exposure. This paper presents a theoretical analysis of the body surface fields induced by electric blankets. Electric blanket exposure intensities are compared to those associated with transmission lines.
1987-04-01
Energy Technology Data Exchange (ETDEWEB)
A generalized approach to the analysis of the effects of transmission line faults on natural gas transmission pipelines has been developed and is presented in this report. A state of the art user-friendly computational tool has been developed and verified for the analysis of interference between electrical power lines and nearby buried or above-ground pipelines. This computer program, ECCAPP, is distinguished by its ability to model and analyze accurately complex, realistic interactions between pipelines and power lines, using easily obtained input data. The final report consists of three volumes. An independent fourth volume was also developed to simplify the installation of the ECCAPP software. This report, volume 1, contains the theory upon which the ECCAPP computer program is based. A parametric analysis and graphical charts have been formulated using ECCAPP ...
1987-11-01
Limitations of traveling wave relaying for overhead EHV transmission lines
Energy Technology Data Exchange (ETDEWEB)
Limitations of traveling wave relaying schemes for protection of overhead extra-high voltage transmission lines are investigated. A method of analysis of traveling wave phenomena for three phase transmission lines is developed in which the interdependent phase voltages and currents are decoupled into their modal counterparts, which are approximately independent. A time domain digital simulation program is used to solve the modal transmission line equations to obtain the fault induced traveling waves detected at the relay location. The frequency dependence of the aerial modes is ignored but their losses are included. A lumped element analysis method, originally developed for transient analysis of lossy coaxial cables, is adapted here to obtain approximate solution for the fault induced traveling waves of the ground mode. Excellent agreement is found between the ...
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
Fourier transform infrared absorption spectroscopy has been used for the determination of the line strengths of 41 CO and CO[sub 2] absorption lines at temperatures between 295 and 1250 K. The CO vibrational-rotational lines were from the [ital P] branch of the fundamental absorption band (2150--1950 cm[sup [minus]1]) while the CO[sub 2] vibrational-rotational lines were from the far wing of the [ital R] branch of the [nu][sub 3] fundamental band (2395--2380 cm[sup [minus]1]). The intensities of the lines were measured from absorption spectra recorded in a high-temperature gas cell containing known concentrations of CO/CO[sub 2]/N[sub 2] gas mixtures at atmospheric pressure. Absorption spectra were recorded through the cell with the use of a moderate-resolution Fourier transform infrared spectrometer. The absorption spectra were mathematically corrected for distortions resulting ...
1994-11-01
International Nuclear Information System (INIS)
Fourier transform infrared absorption spectroscopy has been used for the determination of the line strengths of 41 CO and CO_2 absorption lines at temperatures between 295 and 1250 K. The CO vibrational-rotational lines were from the P branch of the fundamental absorption band (2150--1950 cm"-"1) while the CO_2 vibrational-rotational lines were from the far wing of the R branch of the #nu#_3 fundamental band (2395--2380 cm"-"1). The intensities of the lines were measured from absorption spectra recorded in a high-temperature gas cell containing known concentrations of CO/CO_2/N_2 gas mixtures at atmospheric pressure. Absorption spectra were recorded through the cell with the use of a moderate-resolution Fourier transform infrared spectrometer. The absorption spectra were mathematically corrected for distortions resulting from the finite resolution of the spectrometer and for peak ...
Transcription induces strand-specific mutations at the 5? end of human genes
UK PubMed Central (United Kingdom)
A regional analysis of nucleotide substitution rates along human genes and their flanking regions allows us to quantify the effect of mutational mechanisms associated with transcription in germ line...Full Text Available
2008-08-01
TABLE A: SPTR SITE SELECTION ANALYSIS LOCATION V ... - NASA
OPERATE AT SOUTH POLE WINTER AMBIENTS, GIVEN THE PROJECT'S BUDGET AND TIME LINES . ... 17 MAXIMUM ELECTRICAL LENGHT CONSTRAINED BY Ku-BAND AT 50 FT. ... A MAXIMUM LENGTH OF 50 FEET HAS BEEN SPECIFIED BY THE SYSTEM LINK CALCULATIONS TO ...
Marine Ecosystem Analysis for Wolsung Nuclear Power Plant.
Environmental surveys to provide base-line data for assessing the potential impact of the operation of Wolseong NPP on marine ecosystems were performed at 3-month intervals in 1981. Physico-chemical properties of seawater and gross beta activities in seaw...
1982-01-01
Low-pressure degenerate four-wave mixing spectroscopy with flam atomization
Energy Technology Data Exchange (ETDEWEB)
A combination of degenerate four-wave mixing spectroscopy and a low-pressure sampling technique has been studied for isotopic analysis in an air-acetylene flame. Hyperfine spectra of D lines of sodium and several mixtures of lithium isotopes obtained in this way are presented.
1988-08-01
UK PubMed Central (United Kingdom)
The aim of this study was to survey the expression of an embryonic cytokine gene, MK, in the normal organs and neoplastic tissues of adults. Northern analysis showed that MK mRNA was exclusively expressed...Full Text Available
1993-02-01
Computing in high energy physics
Energy Technology Data Exchange (ETDEWEB)
This book deals with advanced computing applications in physics, and in particular in high energy physics environments. The main subjects covered are networking; vector and parallel processing; and embedded systems. Also examined are topics such as operating systems, future computer architectures and commercial computer products. The book presents solutions that are foreseen as coping, in the future, with computing problems in experimental and theoretical High Energy Physics. In the experimental environment the large amounts of data to be processed offer special problems on-line as well as off-line. For on-line data reduction, embedded special purpose computers, which are often used for trigger applications are applied. For off-line processing, parallel computers such as emulator farms and the cosmic cube may be employed. The analysis of these topics is therefore a main feature of ...
1986-01-01
An assessment of health impacts of electrical power transmission lines
International Nuclear Information System (INIS)
The types of investigations undertaken to test for possible biological effects of extremely low frequency electric fields have been numerous. However, neither animal and plant experimentation nor clinical studies nor experience with operating extremely high voltage transmission lines have to date provided convincing evidence of a harmful effect from exposure to electric fields associated with transmission lines in spite of numerous attempts to find such effects. Analysis of internal fields and currents supports these observations as the levels appear to be too low to affect mammalian cells. Thus, while one can never prove the negative (i.e. that there is no effect), the overwhelming body of evidence indicates that the electric fields associated with high-voltage lines have no deleterious biological effects. (author).
1981-06-26
Energy Technology Data Exchange (ETDEWEB)
High-resolution neutron capture cross section measurements of 55Mn were recently performed at GELINA by Schillebeeckx et al. (2005) and at ORELA by Guber et al. (2007). The analysis of the experimental data was performed with the computer code SAMMY using the Bayesian approach in the resonance parameters representation of the cross sections. The neutron transmission data taken in 1988 by Harvey et al. (2007) and not analyzed before were added to the SAMMY experimental data base. More than 95% of the s-wave resonances and more than 85% of the p-wave resonances were identified in the energy range up to 125 keV, leading to the neutron strength functions S0 = (3.90 0.78) x 10-4 and S1 = (0.45 0.08) x 10-4. About 25% of the d-wave resonances were identified with a possible strength function of S2 = 1.0 x 10-4. The capture cross section calculated at 0.0253 eV is 13.27 b, and the capture resonance integral is 13.52 0.30 b. In the energy range 15 to ...
2008-05-01
Ion beam mixing in Fe/Si and Ta/Si bilayers: Possible effects of ion charges
Energy Technology Data Exchange (ETDEWEB)
Thin Fe and Ta layers of 30-45 nm thickness, deposited via magnetron sputtering on Si (1 0 0) substrates, were bombarded at room temperature with 100 keV Ar{sup 1+} or Ar{sup 8+} or with 250 keV Xe{sup 1+} or Xe{sup 19+} ions in order to test the influence of the ion charge state on the surface sputtering and interface mixing. The samples were characterized by means of Rutherford backscattering at 0.9-3.0 MeV {alpha}-particle energy, time-of-flight elastic recoil detection analysis with a 53 MeV {sup 127}I{sup 10+} beam and atomic force microscopy. No influence of the charge state on the sputtering and athermal mixing rate was observed in the case of the Ta/Si system. However, in the case of the Fe/Si system, the ion charge was observed to have an influence on the mixing rate.
2003-05-01
Energy Technology Data Exchange (ETDEWEB)
A C{sub 60} {sup +} primary ion source has been coupled to an ion microscope secondary ion mass spectrometry (SIMS) instrument to examine sputtering of silicon with an emphasis on possible application of C{sub 60} {sup +} depth profiling for high depth resolution SIMS analysis of silicon semiconductor materials. Unexpectedly, C{sub 60} {sup +} SIMS depth profiling of silicon was found to be complicated by the deposition of an amorphous carbon layer which buries the silicon substrate. Sputtering of the silicon was observed only at the highest accessible beam energies (14.5 keV impact) or by using oxygen backfilling. C{sub 60} {sup +} SIMS depth profiling of As delta-doped test samples at 14.5 keV demonstrated a substantial (factor of 5) degradation in depth resolution compared to Cs{sup +} SIMS depth profiling. This degradation is thought to result from the formation of an unusual platelet-like grain structure on the SIMS ...
2006-07-30
Absolute differential cross sections for the scattering of kilo-electron-volt O atoms
International Nuclear Information System (INIS)
This paper reports measurements of absolute differential cross sections for the direct scattering of oxygen atoms by He, Ne, Ar, Kr, Xe, H_2, N_2, O_2, CO, CO_2, H_2O, SO_2, NH_3, CH_4, CF_4, and SF_6 targets. The measured cross sections include contributions from all elastic and inelastic processes that result in a fast neutral oxygen atom product. Cross sections are presented for 0.5- and 1.5-keV projectile energies over the laboratory angular range 0.2 degree endash 5 degree. When compared in the center-of-mass reference frame, these cross sections exhibit a high degree of similarity in both amplitude and angular dependence. The cross sections for N_2, CO, CO_2, and H_2O are inverted using a partial-wave analysis to yield empirical interaction potentials, which can then be used to extrapolate the measurements down to lower energies. Using these potentials, cross sections are evaluated at 0.1 keV. copyright 1996 The ...
A Remarkable Low-Mass X-ray Binary within 0.1 pc of the Galactic Center
Recent X-ray and radio observations have identified a transient low-mass X-ray binary (LMXB) located only 0.1 pc in projection from the Galactic center, CXOGC J174540.0-290031. In this paper, we report the detailed analysis of X-ray and infrared observations of the transient and its surroundings. Chandra bservations detect the source at a flux of F_X = 2e-12 erg cm^-2 s^-1 (2-8 keV). After accounting for absorption both in the interstellar medium and in material local to the source, the implied luminosity of the source is only L_X = 4e34 erg/s (2-8 keV; D=8 kpc). However, the diffuse X-ray emission near the source also brightened by a factor of 2. The enhanced diffuse X-ray emission lies on top of a known ridge of dust and ionized gas that is visible infrared images. We interpret the X-ray emission as scattered flux from the outburst, and determine that the peak luminosity of CXOGC J174540.0-290031 was >2e36 erg/s. We ...
2005-01-01
Fluence- and exposure-to-dose conversion for human whole-body gamma irradiation
International Nuclear Information System (INIS)
... kev range 10-100 kev range 100-1000 man mev range 01-10 personnel
1978-01-01
Determination of Proper Peaking Time for Ultra Lege detector at Medium Energies
International Nuclear Information System (INIS)
Reducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the optimum peaking time for particular detector systems is important. For this purpose, pure Se and Zn elements were excited by 59.5 keV ?-rays from a 50 mCi 241Am annular radioactive source in this study. The characteristic x-rays emitted from pure Se and Zn elements were detected by using an ultra low energy Ge (Ultra-LEGe) detector connecting Tennelec TC 244 spectroscopy amplifier at different peaking time modes. Overall pulse widths were determined by HM 203-7 oscilloscope connecting amplifier. The proper peaking time for ultra low energy germanium detector (Ultra-LEGe) is determined about 4 ?s.
2008-08-25
Repair of failed 138kV pipe type cable line
Energy Technology Data Exchange (ETDEWEB)
On February 9, 1995 ComEd experienced a pipe type cable failure on 138kV line 13717. Line 1737 is a bulk power transmission cable circuit connecting The Fisk and Crawford generating stations located within city limits. The line is approximately 4.5 miles long and was originally installed in 1975. This line is forced cooled, has 2,500 KCMIL copper conductors with 505 mils of paper insulation in an 8 inch pritec coated steel pipe. The splices are constructed with Voltalit castings. The failure occurred approximately 3,500 feet from Crawford Station. It was easy to locate the failure since the cable joint casing was breached resulting in the loss of approximately 2,600--2,700 gallons of dielectric fluid. Upon field examination B Phase was determined to have failed. The failure occurred 12 inches inside the casing in an area where it was impossible to install a long connector or add an additional short ...
1996-11-01
Lightning performance assessment of Hellenic high voltage transmission lines
Energy Technology Data Exchange (ETDEWEB)
A methodology for assessing the lightning performance of Hellenic high voltage transmission lines has been developed. Its main advantage is that the analysed transmission line is divided into regions and the analysis is conducted separately for each one region, taking into account the individual characteristics, which exist in each one of them. The developed approach intends to offer more accuracy in the assessment of lightning performance of Hellenic high voltage transmission lines and of similar lines, where they run at the same time through a plain region, a coastline and/or a mountainous region. The aims of the paper are to describe in detail the proposed methodology and to present results obtained by its application on operating Hellenic transmission lines of 150 and 400 kV. The computed results are compared with the results produced by another software ...
2008-04-15
Electromigration study of focused ion beam modified metal lines
Energy Technology Data Exchange (ETDEWEB)
Focus ion beam (FIB) technology is a commonly used tool for integrated circuit device modification, failure analysis, and a variety of other applications. However, limited reliability data of FIB altered circuit is available. This study describes the electromigration mechanism of FIB-altered Al(Cu-Si)/Ti-layered metal lines. The electromigration failures encountered resulted in Al voids at the anode end of FIB-deposited W and Al{sub 2}Cu precipitates at the cathode end. A higher frequency of Al extrusions was also observed on samples stressed at higher temperatures. These observations indicated that FIB-W was an effective blocking boundary for Al and Cu, and confirmed that Cu does electromigrate before Al. The electromigration mechanism of the FIB-altered line closely resembles the published results from two-level Al/W-line/stud interconnect studies. An activation energy of 0.66 eV, with a current ...
1995-12-31
The optimization of gamma spectra processing in prompt gamma neutron activation analysis (PGNAA)
International Nuclear Information System (INIS)
The uncertainty of the elemental analysis is one of the major factors governing the utility of on-line Prompt Gamma Neutron Activation Analysis (PGNAA) in the blending and sorting of bulk materials. In this paper, a general method applicable to Gamma spectra processing is presented and applied to PGNAA in mineral industry. Based on the Fourier transform of spectra and their de-correlation in the Fourier space (the improvement of the conditioning of the correlation matrix), processing of overlapping of characteristic peaks minimizes the propagation of random errors, which optimizes the accuracy and decreases the detection limits of elemental analyses. In comparison with classical methods based on the linear combinations of relevant regions of spectra the improvement may be considerable, especially when several elements are interfering. The method is applied to four case stories covering both borehole logging and ...
2009-04-15
Detect and classify faults using neural nets
Energy Technology Data Exchange (ETDEWEB)
The analysis of transmission line faults is essential to the proper performance of the power system. It is required if protective relays are to take the appropriate action and in monitoring the performance of relays, circuit breakers, and other protective and control elements. The detection and classification of transmission line faults is a fundamental component of such fault analysis. Another application of fault analysis is in software packages for automated analysis of digital fault recorder (DFR) files. Recently, such a package, called DFR Assistant, was developed for substation applications. This program can be installed locally in a substation, in which case it is connected directly to the DFR via a high speed parallel link, or it can be installed at a central station, in which case it can be configured to automatically analyze events coming from all ...
1996-10-01
On-line analysis of chemical composition using an FT-Raman spectrometer in the near-ir
Newly commercialized Fourier transform Raman spectroscopic instrumentation provides a simpler alternative for vibrational spectroscopic analysis. Instrument vendors currently design for laboratory use, but there are many potential process applications of these stable, easy to use instruments. Raman spectroscopy is highly suited to analysis of aqueous samples. Near infrared excitation minimized fluorescence interference and allows for remote operation via fiber optic probes. The Department of Energy has funded research at the Measurement and Control Center to establish the utility of this method for on-line composition analysis in distillation columns. Laboratory evaluation and instrument employs an air-cooled laser and a thermoelectrically cooled detector. The device is mounted on a three by foot cart for convenient location in control rooms. Current fiber optic extension cables allow for ...
1992-01-01
Energy Technology Data Exchange (ETDEWEB)
Q/sub ..beta..-values are determined for 18 nuclei (Zr-, Nb-, Mo-, Tc-, Ru- and Rh-nuclides) with mass numbers 101 less than or equal toA less than or equal to106 and A=109 from measurements of beta decay energies which were carried out at the LOHENGRIN mass separator at the Institut Laue-Langevin in Grenoble (France). The given Q/sub ..beta..-values between 2 and 8 MeV show errors of about 1.5% (with the exception of /sup 103/Zr and /sup 105/Nb resp. and /sup 103/Tc for which larger errors result due to statistical resp. systematic reasons): /sup 101/Zr 5500+-70, /sup 101/Nb 4580+-45, /sup 102/Zr 4670+-40, /sup 102/Nb 7230+-70, /sup 103/Zr 6790+-240, /sup 103/ 5740+-70, /sup 103/Mo 3575+-80, /sup 103/Tc 2585+-70, /sup 104/Nb 8250+-130, /sup 104/Mo 2180+-40, /sup 104/Tc 5520+-100, /sup 105/Nb 6570+-150, /sup 105/Mo 4885+-80, /sup 105/Tc 3750+-60, /sup 106/Mo 3515+-45, /sup 106/Tc 6540+-70, /sup 109/Ru 4150+-80, /sup 109/Rh 2550+-50 (all values in keV). For the ...
1986-10-31
International Nuclear Information System (INIS)
Q_#beta#-values are determined for 18 nuclei (Zr-, Nb-, Mo-, Tc-, Ru- and Rh-nuclides) with mass numbers 101 #<=# A #<=# 106 and A=109 from measurements of beta decay energies which were carried out at the LOHENGRIN mass separator at the Institut Laue-Langevin in Grenoble (France). The given Q_#beta#-values between 2 and 8 MeV show errors of about 1.5% (with the exception of "1"0"3Zr and "1"0"5Nb resp. and "1"0"3Tc for which larger errors result due to statistical resp. systematic reasons): "1"0"1Zr 5500#+-#70, "1"0"1Nb 4580#+-#45, "1"0"2Zr 4670#+-#40, "1"0"2Nb 7230#+-#70, "1"0"3Zr 6790#+-#240, "1"0"3 5740#+-#70, "1"0"3Mo 3575#+-#80, "1"0"3Tc 2585#+-#70, "1"0"4Nb 8250#+-#130, "1"0"4Mo 2180#+-#40, "1"0"4Tc 5520#+-#100, "1"0"5Nb 6570#+-#150, "1"0"5Mo 4885#+-#80, "1"0"5Tc 3750#+-#60, "1"0"6Mo 3515#+-#45, "1"0"6Tc 6540#+-#70, "1"0"9Ru 4150#+-#80, "1"0"9Rh 2550#+-#50 (all values in keV). For the measurement of beta-gamma coincidences a #DELTA#E/E-plastic ...
Triple ion-beam studies of radiation damage in 9Cr2WVTa ferritic/martensitic steel
Energy Technology Data Exchange (ETDEWEB)
To simulate radiation damage under a future Spallation Neutron Source (SNS) environment, irradiation experiments were conducted on a candidate 9Cr-2WVTa ferritic/martensitic steel using the Triple Ion Facility (TIF) at ORNL. Irradiation was conducted in single, dual, and triple ion beam modes using 3.5 MeV Fe{sup ++}, 360 keV He{sup +}, and 180 keV H{sup +} at 80, 200, and 350{degrees}C. These irradiations produced various defects comprising black dots, dislocation loops, line dislocations, and gas bubbles, which led to hardening. The largest increase in hardness, over 63 %, was observed after 50 dpa for triple beam irradiation conditions, revealing that both He and H are augmenting the hardening. Hardness increased less than 30 % after 30 dpa at 200{degrees}C by triple beams, compatible with neutron irradiation data from previous work which showed about a 30 % increase in yield strength after 27.2 dpa at 365{degrees}C. ...
1997-11-01
The peak to background method in quantitative ion microprobe analysis of thick biological specimens
Energy Technology Data Exchange (ETDEWEB)
The use of the ratio of the characteristic intensity to the continuum background intensity (P/B ratio) of the X-ray spectrum for a quantitative ion microprobe (IMP) or PIXE (particle induced X-ray emission) analysis of thin biological specimens was proposed previously. The IMP analysis of thick biological specimens is also of considerable practical use. In this paper, the possibility of using the P/B ratio to quantify minor elements in thick biological specimens is investigated. The epoxy resin based standards with gradual concentrations of KCNS up to 0.6 mol/kg and NBS bovine liver were analyzed by a 27 MeV {alpha} particle microprobe. The measured peak to background ratios (between 4.4 to 5.7 keV) agreed well with the theoretical calculations. The calculations showed that the concentration dependence of the P/B ratios was determined mainly by the absorption of X-rays in specimens. The results indicate that the P/B method ...
1991-05-01
X-ray, Optical, and Radio Observations of SN 1999em and SN 1998S
Observations of the Type II-P (plateau) Supernova (SN) 1999em and Type IIn (narrow emission line) SN 1998S have enabled estimation of the profile of the SN ejecta, the structure of the circumstellar medium (CSM) established by the pre-SN stellar wind, and the nature of the shock interaction. SN 1999em is the first and only Type II-P detected at both X-ray and radio wavelengths. It is the least radio luminous and one of the least X-ray luminous SN ever detected (except for the unusual and very close SN 1987A). The Chandra X-ray data indicate non-radiative interaction of SN ejecta with a power-law density profile (rho \\propto r^{-n} with n ~ 7) with a pre-SN wind with a low mass loss rate of ~2 \\times 10^{-6} Msun/yr for a wind velocity of 10 km/sec, in close agreement with radio mass-loss rate estimates. The Chandra data show an unexpected, temporary rise in the 0.4--2.0 keV X-ray flux at ~100 days after explosion. SN 1998S appears reasonably ...
2001-01-01
EB-curing of coatings on wood composite boards
International Nuclear Information System (INIS)
The industrial radiation processing using low energy electron beam (EB) accelerators lower than 300 keV offers high speed, safe technologies for the chemical conversion of thin layer coatings. Because of the nonselective mode of initiating chain reaction polymerization involving free radicals in synthetic coating layers and suitable substrates, the EB curing of the coatings on woods and papers has particular advantage. Hungary decided to start an up-to-date EB line to process cement-bound (CB) wood chipboards with pigmented acrylic coatings. The CB wood chipboards contain more than 60 % of portland cement and up to 40 % of wood particles. They are produced as large boads of 6 - 16 mm thickness. In their fireproof character and other aspects, they are similar to asbestos-cement boards without containing carcinagenic asbestos, and are stable against moisture and atmospheric influences. EB-cured acrylate coating improved further those properties, ...
1988-10-01
Nonlinear dynamic analysis of high energy line pipe whip
Energy Technology Data Exchange (ETDEWEB)
This paper describes a nonlinear dynamic analysis of TVA high energy line pipe whip tests using the ABAQUS-EPGEN code. The analysis considers the effects of large deformation and strain rate on resisting moment and energy absorption capability. The numerical results of impact forces, impact velocities, pipe strains, and reaction forces at pipe supports are compared to the TVA test data. The calculated pipe whip impact time and forces are also compared with those predicted using current industry practice. The calculated pipe support reaction forces are found to be in good agreement with the TVA test data except for some peak values at the very beginning of the pipe break. These peaks are believed to be due to stress wave propagation which cannot be addressed by the ABAQUS code. Both elbow crushing and strain rate have been approximately simulated. The effects are found to be important for pipe whip impact evaluation.
1984-02-01
Energy Technology Data Exchange (ETDEWEB)
The SRI International industrial team completed a subsystem and system parametric analysis, a 100-MW/sub e/ commercial plant conceptual design, a cost and performance analysis, and a commercial assessment. An executive summary is presented in this volume. (WHK)
1980-04-01
From nuclear science symposium; San Francisco, California, USA (14 Nov 1973). A digital Fourier analyzer was programmed to perform reactor neutron noise analysis measurements and on-line processing of the data to obtain the steady-state reactivity. The system is suitable for recovering cross spectral density with low correlatedsignal component and for repetitive measurements with efficient use of reactor time. (auth)
1973-01-01
International Nuclear Information System (INIS)
The thiazolidinedione (TZD) or glitazone class of peroxisome proliferator-activated-#gamma# (PPAR-#gamma#) ligands not only induce adipocyte differentiation and increase insulin sensitivity, but also exert growth inhibitory effects on several carcinoma cell lines in vitro as well as in vivo. In the current study the in vitro effect of four PPAR-#gamma# agonists (ciglitazone, pioglitazone, troglitazone, rosiglitazone) on the cell growth of seven human neuroblastoma cell lines (Kelly, LAN-1, LAN-5, LS, IMR-32, SK-N-SH, SH-SY5Y) was investigated. Growth rates were assessed by a colorimetric XTT-based assay kit. Expression of PPAR-#gamma# protein was examined by immunohistochemistry and Western blot analysis. All glitazones inhibited in vitro growth and viability of the human neuroblastoma cell lines in a dose-dependent manner showing considerable effects only at high concentrations (10 #mu#M and 100 ...
2005-09-15
Xenotropic murine leukemia virus-related virus (XMRV) was discovered in human prostate tumors and later in some chronic fatigue syndrome (CFS) patients. However, subsequent studies have identified various sources of potential contamination with XMRV and other murine leukemia virus (MLV)-related sequences in test samples. Biological and nucleotide sequence analysis indicates that XMRV is distinct from known xenotropic MLVs and has a broad host range and cell tropism including human cells. Therefore, it is prudent to minimize the risk of human exposure to infection by evaluating XMRV contamination in cell lines handled in laboratory research and particularly those used in the manufacture of biological products. Nested DNA PCR assays were optimized for investigating XMRV gag and env sequences in various cell lines, which included MRC-5, Vero, HEK-293, MDCK, HeLa, and A549, that may be used in the development of some vaccines ...
2011-10-11
Energy Technology Data Exchange (ETDEWEB)
Accuracy of an LLP system and a lightning frequency map is evaluated by using transmission line faults in Hokuriku area from November in 1993 to October in 1996. The accuracy and efficiency of the system were calculated by statistical methods. From the above results, the lightning frequency map with 10 minutes meshes was proved capable of replacing the Isokeraunic Level Map with 15 minutes meshes used now for lightning protection design. However, the correlation between the number of detected lightning flashes and transmission line faults in each mesh was found to be week. This result suggests that more detailed analysis taking account of the length of transmission lines in each mesh is necessary. The correlation is stronger in winter than in summer, despite the fact that there is difference in the lightning current distribution in each mesh in winter. This characteristic can be explained if upward ...
1997-10-20
{delta}-excitations and the three-nucleon force
Energy Technology Data Exchange (ETDEWEB)
We study the three-nucleon force in chiral effective field theory with explicit {delta}-resonance degrees of freedom. We show that up to next-to-next-to-leading order, the only contribution to the isospin symmetric three-nucleon force involving the spin-3/2 degrees of freedom is given by the two-pion-exchange diagram with an intermediate delta, frequently called the Fujita-Miyazawa force. We also analyze the leading isospin-breaking corrections due to the delta. For that, we give the first quantitative analysis of the delta quartet mass splittings in chiral effective field theory including the leading electromagnetic corrections. The charge-symmetry breaking three-nucleon force due to an intermediate delta excitation is small, of the order of a few keV.
2008-06-15
The {sup 234}U neutron capture cross section measurement at the n TOF facility
Energy Technology Data Exchange (ETDEWEB)
The neutron capture cross-section of {sup 234}U has been measured for energies from thermal up to the keV region in the neutron time-of-flight facility n-TOF, based on a spallation source located at CERN. A 4{pi} BaF{sub 2} array composed of 40 crystals, placed at a distance of 184.9 m from the neutron source, was employed as a total absorption calorimeter (TAC) for detection of the prompt {gamma}-ray cascade from capture events in the sample. This text describes the experimental setup, all necessary steps followed during the data analysis procedure. Results are presented in the form of R-matrix resonance parameters from fits with the SAMMY code and compared to the evaluated data of Endf in the relevant energy region, indicating the good performance of the n-TOF facility and the TAC. (authors)
2008-07-01
The emission of the plerion G21.5-0.9 appears more extended in X rays than in radio. This is an unexpected result because it would imply that short-lived X-ray electrons may reach distances even larger than radio electrons. Applying an empirical relationship between dust scattering optical depth and photoelectric column density, the measured column density leads to a large optical depth at 1 keV, of about 1. Therefore we investigate the hypothesis that the detected halo be an effect of dust scattering, re-analyzing an Cal/PV XMM-Newton observation of G21.5-0.9 and critically examining it in terms of a dust scattering model. We also present a spectral analysis of a prominent extended feature in the northern sector of the halo.
2003-01-01
Ar/sup +/ ion beam induced silicide formation mechanism at the Pf-Si interface
Energy Technology Data Exchange (ETDEWEB)
Evaporated palladium films of 45 nm thickness on Si(111) were irradiated using 78 keV Ar/sup +/ ions with doses in the range of 1 x 10/sup 15/ to 1.5 x 10/sup 16/ cm/sup -2/ for the purpose of studying silicide formation. Rutherford backscattering analysis shows that intermixing has occurred across the Pd-Si interface at room temperature. The mixing behaviour increases with increasing dose of the bombarding ions, which agrees well with a theoretical model of isotropic cascade mixing for palladium, and radiation-enhanced diffusion associated with an interstitial mechanism for silicon.
1989-01-01
Energy Technology Data Exchange (ETDEWEB)
A generalized approach to the analysis of the effects of transmission line faults on natural gas transmission pipelines has been developed and is presented in this report. A state of the art user-friendly computational tool has been developed and verified for the analysis of interference between electrical power lines and nearby buried or above-ground pipelines. This computer program, ECCAPP, is distinguished by its ability to model and analyze accurately complex, realistic interactions between pipelines and power lines, using easily obtained input data. The final report consists of three volumes. An independent fourth volume was also developed to simplify the installation of the ECCAPP software. Volume 1 contains the theory upon which the ECCAPP computer program is based. A parametric analysis and graphical charts have been formulated using ECCAPP to permit ...
1987-10-01
Energy Technology Data Exchange (ETDEWEB)
Silicon on insulator (SOI) structures are promising candidates for the fabrication of VLSI circuits with very high packing densities. The preparation of such structures can now be achieved by high dose implantation of reactive ion species such as oxygen to produce buried layers of SiO/sub 2/ in silicon. In this paper we report experiments to depth profile these layered structures by SIMS. SOI samples have been prepared by implanting (100) silicon wafers with 400 keV molecular oxygen ions at a dose of 1.8x10/sup 18/ O/sup +/ cm/sup -2/. During the implantation the wafers were maintained at temperatures between 325 and 600/sup 0/C, using beam heating, which achieved in situ-annealing and ensured that the top silicon layer remained single crystal. Analysis was carried out on an Atomika DIDA-II spectrometer using 10 keV Ar/sup +/ ions with a low current density of less than 1 mA cm/sup -2/. During analysis ...
1983-12-15
Checking the condion of 500 kV cable lines by chromatographic analysis of gases dissolved in oil
Energy Technology Data Exchange (ETDEWEB)
A chromatographic technique is described for checking the condition of cable insulation by analyzing cable oil for the gases that are typical of defects in power transformers: carbon dioxide, acetylene, methane and ethylene. This technique was successfully used for predicting breakdown of insulation on KL-2 cable at one of the hydroelectric plants of Kirgizglavenergo power grid 1.5 months in advance. The presence of the above-mentioned gases in cable oil can provide a signal for monitoring the state of cable insulation. Further research is needed in addition to more operational experience to work out criteria for objective evaluation of the state of cable lines.
1980-03-01
Surge-line thermal stratification: Displacements and fatigue damage computations
Energy Technology Data Exchange (ETDEWEB)
Slow, unexpected displacements have been experienced in most pressurized water reactor (PWR) surge lines. Sometimes, these displacement lead to gap closure at the pipe whip restraints. These movements occur because of thermal stratification. This movement has the potential to increase stresses to valves, which may exceed the material yield stress. To understand this phenomenon, Framatome, Commissariat a l'Energie Atomique, and Electricite de France have undertaken large programs for the study of (1) thermal-hydraulic tests with a half-scale Plexiglas surge line, (2) thermal-hydraulic computations of permanent states and transients with a two-dimensional model, and (3) mechanical analysis of displacements and computation of fatigue damage due to stratification. This paper deals with the last subject. Avoiding stratification in piping by process modifications is difficult because of the high flow rate needed. ...
1989-01-01
British Library Electronic Table of Contents (United Kingdom)
This paper presents a dynamic displacement influence line method for moving load identification on bridge. The finite element model of Poyang Lake continuous truss bridge-train systems is established and the dispersed modal shapes are acquired by modal analysis. Multi-axle moving train loads are identified with simulated annealing genetic algorithm by minimizing the errors between the measured displacements and the reconstructed displacements from the identified moving loads. In the identification process, the dynamic displacement influence line technique is used to calculate the time history displacement responses of the bridge to avoid solving equations of motion of the bridge repetitively. Several important parameters of the bridge-train system are discussed to investigate their effects...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
The efficiency of dendrosome (a gene porter) was assessed in transferring recombinant human rotavirus VP2 cDNA into A549, a human lung cell line. After gene transferring, transmission electron microscopy showed core-like particles (CLPs) formation in the transfected cells both with dendrosome and lipofectamine porters. In addition, western blotting analysis showed that the expression of VP2 gene was almost equal in the dendrosome and lipofectamine-transfected cells. Also, the cytotoxicity studies revealed that dendrosome had a lower cytotoxicity than lipofectamine. Therefore, our study may introduce dendrosome as a possible carrier for gene transferring into the human lung cell line, especially, for intranasally administration of DNA vaccines.
2009-01-01
A novel wavelet transform aided neural network based transmission line fault analysis method
Energy Technology Data Exchange (ETDEWEB)
In the present scenario of market driven business, power supply has become more like a commodity. Reliable and quality power need to be ensured to meet customer requirements. In such a situation, it is extremely important that transmission line faults be identified accurately, reliably and in quick time. Advanced signal processing tools such as discrete wavelet transform (DWT) can be used very effectively for parameterisation and characterization of the fault signals. On the other hand, properly configured neural network (NN) can be utilized for classification of the faults based on the DWT signal. The present contribution uses electromagnetic transient program (EMTP) for modeling of a real transmission system and MATLAB for DWT and NN. Various types of faults have been simulated at different locations along the transmission line and an attempt has been made to correctly identify and locate the fault. (author)
2009-06-15
Energy Technology Data Exchange (ETDEWEB)
Populations living close to high-voltage transmission lines often have residential magnetic field exposures in excess of 1 [mu]T, and sometimes over 2 [mu]T. Yet, populations studied in most epidemiologic investigations of the association between residential magnetic field exposure and cancer typically have exposures below 1 [mu]T and frequently below 0.5 [mu]T. To improve statistical power and precision, it would be useful to compare high exposure populations with low exposure population. Toward this end, we have developed an automated method for identifying populations living near high-voltage transmissions lines. These populations likely have more highly exposed individuals that the population at large. The method uses a geographic information system (GIS) to superimpose digitized transmission line locations on U.S. Census block location data and then extract relevant demographic data. Analysis of ...
1993-12-01
Radioanalytical determination of chromium in welding fumes
International Nuclear Information System (INIS)
Radionuclide X-ray fluorescence analysis and fast neutron activation analysis were used for the determination of chromium. The excitation source for X-ray fluorescence analysis was a ring-shaped "2"4"1Am source with an activity of 18.5x10"9 Bq. SYNPOR filters of 35 mm in diameter were used for the measurement. The 5.414 keV Cr peak was measured with a Si(Li) detector. The sensitivity was 0.05 mg for a period of measurement of 1000 s. A neutron generator with an emission of 10"9 s"-"1 was used as the source of fast neutrons. "5"2V and "5"3V, the products of nuclear reaction with Cr, were measured gamma spectrometrically with a Ge(Li) detector. The sensitivity for Cr is 0.015 mg, in the presence of Mn which causes interference the sensitivity is a mere 0.075 mg. The mentioned methods were used to determine total Cr and Cr(VI) in welding aerosols. It was found that the most toxic form, i.e., Cr(VI), is ...
1985-01-01
The authors develop a procedure for the determination of the Al, Ti, V, Cu, Mn, Mo, and W content of nickel-base alloys by neutron activation analysis. An M-10 microtron with a beryllium target in a paraffin microtron (with a beryllium target) in a paraffin moderator served as the neutron source. In order to evaluate the procedure for quantitative analysis, the authors determined the contents of the above elements in five reference standards, the bulk density of which was 2.94-4.17 g/cm/sup 3/. The difference in the self-absorption of the gammaquanta was assessed by determining the number of gamma-quanta with energies in the range 60-1332 keV that had passed through the RS N4 and N8 which showed the greatest difference in their composition. The results of the determination are presented. The proposed procedure is simple and rapid and can be used to determine the alloying components of nickel-based alloys with satisfactory ...
1986-04-01
International Nuclear Information System (INIS)
The authors develop a procedure for the determination of the Al, Ti, V, Cu, Mn, Mo, and W content of nickel-base alloys by neutron activation analysis. An M-10 microtron with a beryllium target in a paraffin microtron (with a beryllium target) in a paraffin moderator served as the neutron source. In order to evaluate the procedure for quantitative analysis, the authors determined the contents of the above elements in five reference standards, the bulk density of which was 2.94-4.17 g/cm"3. The difference in the self-absorption of the gammaquanta was assessed by determining the number of gamma-quanta with energies in the range 60-1332 keV that had passed through the RS N4 and N8 which showed the greatest difference in their composition. The results of the determination are presented. The proposed procedure is simple and rapid and can be used to determine the alloying components of nickel-based alloys with satisfactory ...
International Nuclear Information System (INIS)
We report a study of the physical characteristics of the pillars of C, Pt and W grown by 10-30 keV Ga focused ion beam (FIB) as a function of Ga ion flux, and present a quantitative analysis of the elements using energy-dispersive analysis of X-rays (EDAX). All the FIB grown pillars exhibit a rough morphology with whisker like protrusions on the cylindrical surface and broadening of the base as compared to the nominal size. For a constant fluence, the height of the pillar initially increases and then reduces after going through a maximum as a function of ion flux in all the cases. The compositional analysis shows good metallic quality for Pt structures but reveals significant contamination of Ga in C and Ga and C in W structures at higher ion fluxes. Explanation to all these observations has been sought in the light of secondary ion and electron effects and the different processes involved which lead to ...
2008-04-01
International Nuclear Information System (INIS)
The total interaction cross sections (#sigma#_t) of some sugars and amino acids and five elements: lithium, carbon, oxygen, aluminium and calcium have been measured for 6.4 keV, 13.95 keV, 14.4 keV, 17.74 keV, 24.14 keV, 30.8 keV, 35 keV, 59.54 keV, 81 keV, 122 keV and 136 keV photons in a narrow beam good geometry set up, by using high resolution detectors such as a Si-PIN diode detector and a high purity germanium detector. The #sigma#_t values have been used in a matrix method to evaluate the effective atomic numbers Z_e_f_f of the samples from their effective atomic cross sections #sigma#_a. The effective atomic cross section of a sample #sigma#_a is the total interaction cross section divided by the total number of atoms of all types in it. Further, a ...
2007-09-28
International Nuclear Information System (INIS)
The major feed-water line break accident is re-analyzed, which is based on Guangdong Daya Bay nuclear power station final safety analysis report, to justify the impacts of the decreasing of auxiliary feed-water flow rate on the safety margin in Daya Bay. The results showed that the accident analysis can meet the demands of acceptance criteria with the auxiliary feed-water flowrate decreasing from 45 m"3/h to 41.8 m"3/h, and enough safety margin is still retained
2002-06-01
3. Physical foundations and methodology of radionuclide X-ray fluorescence analysis
International Nuclear Information System (INIS)
The physical foundations are described of radionuclide X-ray fluorescence analysis (RXFA) and the table shows the values of K- and L-absorption thresholds and the K- and L-line energies of elements. The calculation of the intensity of characteristic radiation during RXFA proceeds from relations derived for conventional X-ray fluorescence analysis. The choice of the radionuclide source is ruled by the nature of the analysed substance and the used detection technique. The diagram shows the areas of radionuclide sources and the energy of the fluorescence radiation of elements. The table shows the spectra of radionuclide sources suitable for the purposes of RXFA measured by semiconductor Si(Li) and Ge(Li) detectors. (ES).
1983-12-01
Nonlinear dynamic analysis of high energy line pipe whip
International Nuclear Information System (INIS)
To facilitate potential cost savings in pipe whip protection design, TVA conducted a 1'' high pressure line break test to investigate the pipe whip behavior. The test results are available to EPRI as a data base for a generic study on nonlinear dynamic behavior of piping systems and pipe whip phenomena. This paper describes a nonlinear dynamic analysis of the TVA high energy line tests using ABAQUS-EPGEN code. The analysis considers the effects of large deformation and high strain rate on resisting moment and energy absorption capability of the analyzed piping system. The numerical results of impact forces, impact velocities, and reaction forces at pipe supports are compared to the TVA test data. The pipe whip impact time and forces have also been calculated per the current NRC guidelines and compared. The calculated pipe support reaction forces prior to impact have been found to be in good agreement ...
Energy Technology Data Exchange (ETDEWEB)
Groom-Bailey decomposition analysis was carried out to investigate regional 3-D galvanic distortion on MT data in the central part of Northeastern Japan. Measuring sites were located nearly along the east-west line crossing Northeastern Japan. Three measuring lines (A, B, C) from the north to the south were prepared, and only data on the C line were analyzed in this paper. As a result, twist and shear were estimated to be not zero depending on local distortion in most of the sites. It was thus clarified that this method is not always perfect. This method was effective for regional 2-D structures, however, its application was doubtful to complicated 3-D underground structures in Japan. In order to obtain more accurate results, 2-D analysis using the impedance including no local distortion effect was necessary after the preliminary Groom-Bailey decomposition ...
1996-10-01
Investigation by XRF and XRD of Zn and Fe in Fe{sub x} Zn{sub 1-x} thin films
Energy Technology Data Exchange (ETDEWEB)
Fe{sub x}Zn{sub 1-x} alloys were electrochemically deposited on aluminum substrates from a sulfate bath. The K{beta}/K{alpha} x-ray intensity ratios of Zn and Fe in Fe{sub x}Zn{sub 1-x} thin films have been experimentally studied. The energy dispersive x-ray fluorescence (EDXRF) technique was used to measure K x-ray photons. Samples were excited by using 59.5 keV photons emitted by a 50 mCi {sup 241}Am radioactive source. The emitted K x-rays were detected by an Ultra-LEGe detector having a resolution of 150 eV at 5.9 keV. In addition, the effect of bath composition on the phase structure was investigated by x-ray diffraction (XRD) analysis. The composition of the thin films was analyzed by atomic absorption spectrometry analysis. Iron content was shown to strongly affect the structure of Zn-Fe alloys. It was found that the K-shell x-ray intensity ratio changed in Fe{sub x}Zn{sub 1-x} thin films for ...
2008-12-15
Investigation by XRF and XRD of Zn and Fe in Fex Zn1-x thin films
International Nuclear Information System (INIS)
FexZn1-x alloys were electrochemically deposited on aluminum substrates from a sulfate bath. The K?/K? x-ray intensity ratios of Zn and Fe in FexZn1-x thin films have been experimentally studied. The energy dispersive x-ray fluorescence (EDXRF) technique was used to measure K x-ray photons. Samples were excited by using 59.5 keV photons emitted by a 50 mCi 241Am radioactive source. The emitted K x-rays were detected by an Ultra-LEGe detector having a resolution of 150 eV at 5.9 keV. In addition, the effect of bath composition on the phase structure was investigated by x-ray diffraction (XRD) analysis. The composition of the thin films was analyzed by atomic absorption spectrometry analysis. Iron content was shown to strongly affect the structure of Zn-Fe alloys. It was found that the K-shell x-ray intensity ratio changed in FexZn1-x thin films for different values of x. The reason for this change may be ...
2008-12-01
British Library Electronic Table of Contents (United Kingdom)
Antisense- or RNAi-mediated suppression of the biosynthesis of nutritionally inferior storage proteins is a promising strategy for improving the amino acid profile of seeds. However, the potential pleiotropic effects of this on interconnected pathways and the agronomic quality traits need to be addressed. In the current study, a transcriptomic analysis of an antisense C-hordein line of barley was performed, using a grain-specific cDNA array. The C-hordein antisense line is characterized by marked changes in storage protein and amino acid profiles, while the seed weight is within the normal range and no external morphological irregularities were observed. The results of the transcriptome analysis showed excellent correlation with data on changes in the relative proportions of storage protei...
2007-01-01
Radioanalytical methods of rare earth element determination
International Nuclear Information System (INIS)
Instrumental neutron activation analysis (INAA) and radionuclide X-ray fluorescence analysis (RXFA) were used for the determination of rare earth elements. For INAA, solution obtained by sample decomposition was dripped onto filter paper, enclosed and sealed into a polyethylene foil. The sample was activated in reactor WWR-S over a period of 4 to 6 hours with a neutron fluence of 10"1"3cm"-"2. Gamma radiation measurement was carried out with a planar and a coaxial HP-Ge detector in three decay periods. La, Ce, Nd, Sm, Eu, Gd, Tb, Ho, Tm, Yb and Lu were determined. The advantage of the method is its accuracy and high sensitivity, the disadvantage is the time-consuming analysis. The RXFA method was used as a rapid and operative method for the analysis of loose ore samples, aqueous and organic solutions of rare earth elements. For exciting X-ray radiation, "2"4"1Am was used and the radiation of ...
1989-06-01
International Nuclear Information System (INIS)
Classical beam line ion implantation is limited to low energies and cannot achieve P+/N junctions requested for <45nm ITRS node. RTA (rapid thermal annealing) needs to be improved for dopants activation and damage reductions. Spike annealing process also induces a large diffusion mainly due to TED (transient enhanced diffusion). Compared to conventional beam line ion implantation limited to a minimum energy implantation of 200eV, plasma immersion ion implantation (PIII) is an emerging technique to get ultimate shallow profiles (as-implanted) due to no lower limitation of energy and high dose rate. On the another hand, laser thermal processing (LTP) allows to obtain very shallow junction with no TED, abrupt profile and activated depth control. In this paper, we show the implementation of the BF_3 PIII associated with the LTP. Ions from BF_3"+ plasma have been implanted in 200mm n-type silicon wafers with energies from 100eV to ...
2005-08-01
Line intensity enhancements in stellar coronal X-ray spectra due to opacity effects
Context. The I(15.01 A)/I(16.78 A) emission line intensity ratio in Fe XVII has been reported to deviate from its theoretical value in solar and stellar X-ray spectra. This is attributed to opacity in the 15.01 A line, leading to a reduction in its intensity, and was interpreted in terms of a geometry in which the emitters and absorbers are spatially distinct. Aims. We study the I(15.01 A)/I(16.78 A) intensity ratio for the active cool dwarf EV Lac, in both flare and quiescent spectra. Methods. The observations were obtained with the Reflection Grating Spectrometer on the XMM-Newton satellite. The emission measure distribution versus temperature reconstruction technique is used for our analysis. Results. We find that the 15.01 A line exhibits a significant enhancement in intensity over the optically thin value. To our knowledge, this is the first time that such an enhancement has been detected on such a ...
2008-01-01
Complex Spatio-Spectral Structure of Diffuse X-Ray emission in the ...
SN 1987A: Soft X-Ray Intensity Ratio. 2002-12 to 2000-12. 2005-7 to 2002-12. Contours: 2002-12. (0.5 2 keV). (0.5 2 keV). Contours: 2005-7 ...
Iridium and PGE in sedimentary rocks; Iridium et platinoides dans les roches sedimentaires
Energy Technology Data Exchange (ETDEWEB)
The detection limit of Instrumental Neutron Activation Analysis (INAA), about a few microgram per kg, is not sufficient to determine iridium concentrations in most geological samples. Use of the coincidence counting of the 316 and 468 keV gamma-rays emitted during the decay of {sup 192}Ir, improved the sensitivity (0.01 microgram per kg). The high iridium content of the clay layers from the Cretaceous-Tertiary transition (KTB) has been considered as an evidence of the extra-terrestrial origin of the KTB mass extinction. However some results indicate that a significant part of the iridium content in sediments has a volcanic origin. Radiochemical Neutron Activation Analysis (RNAA) in some KTB samples and in basic and ultra-basic rocks show that, unlike in volcanic products, no PGE (platinoids) fractionation appears in KTB samples. The nearby chondritic PGE pattern supports an extra-terrestrial origin for the KTB iridium ...
1994-12-31
Electron capture decay of sup 203 Pb
Energy Technology Data Exchange (ETDEWEB)
Intensities of {gamma}-transitions emerging from the EC decay of {sup 203}Pb were measured precisely. The obtained relative {gamma}-intensities are 100%(279.2keV), 4.14+-0.08%(401.3keV) and 0.932+-0.022%(680.5keV). The 279.2 and 680.5keV level feeding {beta}-branching ratios were deduced to be 95.3+-0.1 and 4.7+-0.1% respectively. {sup 203}Pb is suggested for calibration purposes. (author).
1989-01-01
8"+ isomers in N=48 isotones and E2 polarization charges
International Nuclear Information System (INIS)
... charges energy levels gamma spectra half-life isomeric nuclei kev range
1972-05-01
Energy Technology Data Exchange (ETDEWEB)
The Feedwater System supplies feedwater to the steam generator at the required pressure, temperature and flow rate during the plant start-up, normal power operation, shutdown. When the Feedwater System is inoperable or unavailable, the Auxiliary Feedwater System supplies emergency feedwater to the steam generator. If main steam line break occurs, the increase of feedwater flow rate of the faulted steam generator due to decrease of the pressure in the faulted steam generator results in adverse effects in aspect of overcooling the Reactor Coolant System and increased containment pressure/temperature. To optimize the containment mass/energy analysis, this paper evaluates the maximum feedwater and auxiliary feedwater flow rate delivered to the faulted steam generator at each stage of pressure decrease in the faulted steam generator after a main steam line break accident. Calculated Feedwater flows are applied to calculate mass ...
2001-05-01
Die Backside FIB Preparation for Identification and Characterization of Metal Voids
Energy Technology Data Exchange (ETDEWEB)
Both the increased complexity of integrated circuits, resulting in six or more levels of integration, and the increasing use of flip-chip packaging have driven the development of integrated circuit (IC) failure analysis tools that can be applied to the backside of the chip. Among these new approaches are focused ion beam (FIB) tools and processes for performing chip edits/repairs from the die backside. This paper describes the use of backside FIB for a failure analysis application rather than for chip repair. Specifically, they used FIB technology to prepare an IC for inspection of voided metal interconnects (lines) and vias. Conventional FIB milling was combined with a super-enhanced gas assisted milling process that uses XeF{sub 2} for rapid removal of large volumes of bulk silicon. This combined approach allowed removal of the TiW underlayer from a large number of Ml lines simultaneously, enabling ...
1999-07-28
Motion analysis of parallelly connected FPSO unit and LNG carrier
Energy Technology Data Exchange (ETDEWEB)
Nowadays, the floating production, storage, and offloading (FPSO) units are used to marginal oil fields and deep seas, because of mobility and reduced lead time from discovery to first production. One of the methods for offloading is to moor a tanker alongside the FPSO unit. In this case motion response of the system becomes highly complex, and will be affected by many factors such as hydrodynamic interaction and mechanical connections between the vessels. In this study, a quite general method is developed which has taken into account the hydrodynamic interaction as well as the effects of connectors and mooring lines, in motion response analysis of a multi-body floating system. For this purpose, 3-D source distribution method is applied for hydrodynamic analysis, and linear stiffness matrices are introduced to represent the effect of connectors and mooring lines on the motion equations. The method has ...
1996-12-31
International Nuclear Information System (INIS)
An analysis is presented of the motion of test particles in Goedel's universe. Both geodesical and nongeodesical motions are considered; the accelerations for nongeodesical motions are given. Examples for closed timelike world lines are shown and the dynamical conditions for time travel in Goedel's space-time are discussed. It is shown that these conditions alone do not suffice to exclude time travel in Goedel's space-time. (author).
1981-01-01
Observational study of the eclipsing binary RZ Ophiuchi
International Nuclear Information System (INIS)
Orbital elements are derived from new spectroscopic and photometric observations. The masses and radii are inconsistent with evolutionary tracks for single stars, but neither star fills its Roche lobe. Analysis of the circumstellar Balmer emission lines indicates that the primary is surrounded by an extensive, highly flattened disk of nonuniform density. The velocity gradient in the disk is steeper than that expected from Keplerian motion.
International Nuclear Information System (INIS)
The complexing of paramagnetic salts of molybdenum and tungsten with tri-tert-butylphenyl ester of 1,2-naphthoquinone-diazide-(2)-5-sulfochloride is studied by PMR and EPR methods. From the changes of half-widths of lines in PMR spectra and analysis of g-factor in EPR spectra, the kinetic and thermodynamic parameters of the complexing are determined, and the composition of the complexes formed is established, and the schemes of their formation are suggested.
British Library Electronic Table of Contents (United Kingdom)
E-beam and gamma products from the radiolysis of aqueous solutions of (+-)-metoprolol tartrate, saturated in nitrogen, are analyzed by HPLC with on-line mass and UV detectors. The structures of 10 radiolytic products common to e-beam and gamma irradiations are elucidated by comparing their fragmentation pattern to that of (+-)-metoprolol. Two of the radiolytic products are also metabolites. Different routes for the formation of the radiolytic products are proposed.
2006-01-01
International Nuclear Information System (INIS)
Track analysis of medium energy #alpha# particle trajectories recorded in fine grain nuclear emulsion submitted to specific intensifying treatments led to the observation of strong ionizing events (SIE) sticking out of the primary's track core. Preliminary determinations showed that the number of SIEs increases with the primary's energy, and that their production is of more than one order of magnitude higher than the number of Rutherford recoils. The presence of SIEs on monoenergetic #alpha# tracks also has a significant influence on the measured range distribution, which, expressed in terms of energy loss, results in a mean contribution to the total energy loss of far reaching (SIEs (radial spread >= 0.458 #mu#m) of proportional 25 keV per 13.6 MeV #alpha# particle, instead of 0.75 keV in the case where only the Rutherford interactions are taken into account. Measurements carried out in detectors enriched with gelatin ...
/sup 242/Am/sup m/ fission cross section
Energy Technology Data Exchange (ETDEWEB)
The neutron-induced fission cross section of /sup 242/Am/sup m/ has been measured over the energy region from 10/sup -3/ eV to approx.20 MeV in a series of experiments utilizing a linac-produced ''white'' neutron source and a monoenergetic source of 14.1 MeV neutrons. The cross section was measured relative to that of /sup 235/U in the thermal (0.001 to approx.3 eV) and high energy (1 keV to approx.20 MeV) regions and normalized to the ENDF/B-V /sup 235/U(n,f) evaluated cross section. In the resonance energy region (0.5 eV to 10 keV) the neutron flux was measured using thin lithium glass scintillators and the relative cross section thus obtained was normalized to the thermal energy measurement. This procedure allowed a consistency check between the thermal and high energy data. The cross section data have a statistical accuracy of approx.0.5% at thermal energies and in the 1-MeV energy region, and a ...
1984-06-01
Manitoba Hydro long-term high-voltage transmission line magnetic field monitoring project
International Nuclear Information System (INIS)
As part of the licensing process to construct a new 230 kV transmission line on an existing right-of-way in Manitoba, an electrical effects study was conducted in 1998. The study was part of the environmental assessment program crucial in obtaining government approval to construct the line. Some residents living adjacent to the new transmission circuit expressed concerns about alleged adverse health effects associated with long-term exposure to magnetic fields from high voltage transmission lines. In order to verify the accuracy of the predicted magnetic field levels submitted to the regulatory body in the the electrical effects study and to instill confidence in the residents of the affected communities, a three-year magnetic monitoring project was conducted between 2003 and 2005 along the right-of-way after the new 230kV transmission line was energized by Manitoba Hydro. This paper described the ...
2008-10-19
Structure of the triplet of low-lying states in sup 101 Mo
Energy Technology Data Exchange (ETDEWEB)
The properties of the triplet of low-lying states in {sup 101}Mo have been studied through spectroscopy of the {gamma} radation following thermal neutron capture in {sup 100}Mo and {beta}-decay of {sup 101}Nb and through a measurement of the proton angular distributions in the {sup 100}Mo(d, p) reaction with 14 MeV deuteron energy. The half-lives of the 13.5 keV state and the 57.0 keV 5/2{sup +} state have been measured as 226(7) and 133(7) ns, respectively. These values and the quadrupole/dipole mixing ratios of the 13.5 keV and 43.5 keV transitions yield spin and parity 3/2{sup +} for the 13.5 keV level. The E2 components in the 13.5 (3/2{sup +}->1/2{sup +}) and 43.5 keV (5/2{sup +}->3/2{sup +}) transitions are {le} 8x10{sup -4} and 54(9)%, respectively. The possibility of an additional state near to the 57.0 keV level is discussed. ...
1991-06-01
Structure of the triplet of low-lying states in "1"0"1Mo
International Nuclear Information System (INIS)
The properties of the triplet of low-lying states in "1"0"1Mo have been studied through spectroscopy of the #gamma# radation following thermal neutron capture in "1"0"0Mo and #beta#-decay of "1"0"1Nb and through a measurement of the proton angular distributions in the "1"0"0Mo(d, p) reaction with 14 MeV deuteron energy. The half-lives of the 13.5 keV state and the 57.0 keV 5/2"+ state have been measured as 226(7) and 133(7) ns, respectively. These values and the quadrupole/dipole mixing ratios of the 13.5 keV and 43.5 keV transitions yield spin and parity 3/2"+ for the 13.5 keV level. The E2 components in the 13.5 (3/2"+#->#1/2"+) and 43.5 keV (5/2"+#->#3/2"+) transitions are #<=# 8x10"-"4 and 54(9)%, respectively. The possibility of an additional state near to the 57.0 keV level is discussed. IBFM/PTQM calculations, taking into ...
Premnalatifolin A, a novel dimeric diterpene from Premna latifolia Roxb
British Library Electronic Table of Contents (United Kingdom)
Premnalatifolin A (1), a unique icetexane diterpene dimer was isolated from the stem-bark of Indian medicinal plant, Premna latifolia. Its structure and relative stereochemistry were elucidated on the basis of detailed spectroscopic analysis, including HRESIMS and 2D NMR (COSY, HSQC, HMBC, and NOESY) spectra. The compound has dimeric carbon skeleton composed of two icetexane skeletal diterpenes linked via ether bond. Further, premnalatifolin A (1) was also evaluated for its cytotoxicity against cancer cell lines (HT-29, A-431, MCF-7, Hep-G2, PC-3, A-549, B-16 F10, and ACHN), which displayed potent activity against HT-29 and MCF-7 cell lines with the IC50 values of 12.15 and 1.11mg/mL, respectively.
2011-01-01
Nuclear structure studies of [sup 187]Ir via on-line nuclear orientation
Energy Technology Data Exchange (ETDEWEB)
A more complete level scheme is presented here for the decay of [sup 187]Pt, incorporating many new lines and levels up to 2.4 MeV. Emphasis has been placed on the extraction of multipole mixing ratios from nuclear orientation data. Analysis of that data, however, required a more complete understanding of the level structure (including, in particular, branching ratios, conversion coefficients, and level feedings), prompting the collection of new spectroscopy data. The low-lying, positive-parity levels are described in terms of (odd-proton) single-particle Nilsson states coupled to a triaxial core. Multipole mixing ratios are compared to those calculated in the Particle-Plus-Triaxial-Rotor Model. (orig.).
1992-11-01
Nuclear structure studies of "1"8"7Ir via on-line nuclear orientation
International Nuclear Information System (INIS)
A more complete level scheme is presented here for the decay of "1"8"7Pt, incorporating many new lines and levels up to 2.4 MeV. Emphasis has been placed on the extraction of multipole mixing ratios from nuclear orientation data. Analysis of that data, however, required a more complete understanding of the level structure (including, in particular, branching ratios, conversion coefficients, and level feedings), prompting the collection of new spectroscopy data. The low-lying, positive-parity levels are described in terms of (odd-proton) single-particle Nilsson states coupled to a triaxial core. Multipole mixing ratios are compared to those calculated in the Particle-Plus-Triaxial-Rotor Model. (orig.).
Energy Technology Data Exchange (ETDEWEB)
The transmission of electrical energy by use of underground cables is increasing. Fault location techniques have certain limitations; incipient fault detection and location would help reduce the maintenance cost of these lines as well as improve the reliability of service. The report discusses some test results related to RF-probing techniques applied to high-voltage transmission lines. The high-frequency losses and attenuation in high-voltage cables places certain ultimate limitations on RF-probing techniques for incipient fault detection. Time-domain reflectrometry methods were employed to assess the RF-transmission properties of high-voltage cables at frequencies as high as 6 GHz. Fast-Fourier-transform deconvolution was used to obtain loss measurements as a function of frequency. The loss mechanisms were identified. The measurement hardware and methods are discussed as well as analysis approach leading to the ...
1986-04-01
Evaluation of routine telephone transmission of nuclear medicine studies
Energy Technology Data Exchange (ETDEWEB)
Rapid and reliable transmission of nuclear medicine studies using conventional telephone lines and commercially available modems and computer systems has been accomplished through use of software developed within the authors' hospital. Original digital images of all-night and weekend studies, acquired on any of the acquisition computers from different manufacturers, are now routinely sent for remote reading at the physician's home. Data, software, and letters are routinely exchanged using modems and standard telephone lines with a sister institution in Haifa, Israel. The software has been designed to achieve no loss data compression and minimal turnaround time loss. Thus, an average lung perfusion image or gallbladder study requires about 1-3 minutes of transmission time. Full analysis and display software is available on the remote computer.
1989-01-01
Energy Technology Data Exchange (ETDEWEB)
An adaptive contingency selection process is set up which produces outage lists in order to guarantee on-line network security control. The quality index system used so far did not detect and reveal all critical variables due to observation problems in the mapping of two functions. The new process uses the results of the outage simulation computing of the system status just past for the drawing up of an up-to-date outage list. A linear correcting function transform the G{sub 2}-values of the standard quality index method - which still incorporate the observation problem effect - into improved values G. Studies which use data from realstic high-voltage networks prove that the detection of critical variables is far superior to ordinary methods. (orig.).
1990-04-23
In their Letter [Phys. Rev. Lett. 92, 121302 (2004)] (also [Astron. Astrophys. 417, 853 (2004)]), Srianand et al. analysed optical spectra of heavy-element species in 23 absorption systems along background quasar sight-lines, reporting limits on relative variations in the fine-structure constant: da/a=(-0.06+/-0.06) x 10^{-5}. Here we demonstrate basic flaws in their analysis, using the same data and absorption profile fits, which led to spurious values of da/a and significantly underestimated uncertainties. We conclude that these data and fits offer no stringent test of previous evidence for a varying alpha.
2007-01-01
International Nuclear Information System (INIS)
In the analysis of power systems security, recently a new concern related to possible malicious attacks caught much attention. Coordination among different transmission system operators (TSO) in an interconnected power system to counteract such attacks has become an important problem. This paper presents a general framework for describing the physical, cyber and decision-making aspects of the problem and their interrelations; within this framework, an analytic tool for the assessment of information impacts in handling on-line security after a malicious attack is proposed and discussed. The model is based on the socially rational multi-agent systems and the equilibrium of a fictitious play is considered to analyze the impacts of various levels of information available to the interconnected system operators on the outcomes of the decision-making process under attack. A 34-buses test system, with 3 systems interconnected by ...
2009-06-01
A novel wavelet transform aided neural network based transmission line fault analysis method
British Library Electronic Table of Contents (United Kingdom)
In the present scenario of market driven business, power supply has become more like a commodity. Reliable and quality power need to be ensured to meet customer requirements. In such a situation, it is extremely important that transmission line faults be identified accurately, reliably and in quick time. Advanced signal processing tools such as discrete wavelet transform (DWT) can be used very effectively for parameterisation and characterization of the fault signals. On the other hand, properly configured neural network (NN) can be utilized for classification of the faults based on the DWT signal. The present contribution uses electromagnetic transient program (EMTP) for modeling of a real transmission system and MATLAB for DWT and NN. Various types of faults have been simulated at differ...
2009-01-01
State of the Art Laser Induced Breakdown Spectroscopy
International Nuclear Information System (INIS)
Methods currently being used or developed for the elemental analysis of materials are chemical analysis, non-destructive inspection and calorimetry. The chemical analysis, which removes high-level radioactive elements through chemical treatments and then performs the quantitative analysis using the ICP-MS(Inductively Coupled Plasma - Mass Spectrometer) or the ID-MS(Isotope Dilution Mass Spectrometer), is recognized the most accurate. However, it requires a long, complex pre-treatment process in which a mass spectrometer could be contaminated. To solve this problem, a new method, which can be performed with high-level radioactivity and at high temperature, was desired. Such a method should also have the same accuracy as the chemical analysis, with a less possibility for instruments to be contaminated. In addition, as interests in the environment and the life quality are increased, a ...
English - Downed Power Lines Click to Stop Video Click to Start Video To Listen to the Audio ...
XPS study of passive films formed on molybdenum-implanted austenitic stainless steels
Energy Technology Data Exchange (ETDEWEB)
Austenitic stainless steels have been implanted with molybdenum ions (Mo[sup +], 100 keV, 2.5 x 10[sup 16] atoms cm[sup -2]). The implanted material has been characterized by XPS and RBS. The implanted region has a thickness of [approx] 1000 A with a maximum molybdenum concentration of [approx] 9 at.% Mo located at [approx] 210 A from the surface. The effects of implanted molybdenum on the passivation of the alloy in 0.5 M H[sub 2]SO[sub 4] have been investigated by electrochemistry and XPS. After XPS analysis the samples were transferred without exposure to air into a glove-box with an inert atmosphere. The electrochemical behaviour of the alloy is significantly modified by the implanted molybdenum. The major effect is that the activation peak disappears. A bilayer structure (outer hydroxide/inner oxide) of the passive film is observed for both the implanted and non-implanted alloys and the thicknesses of the films are similar. On the ...
1992-06-01
XPS study of passive films formed on molybdenum-implanted austenitic stainless steels
International Nuclear Information System (INIS)
Austenitic stainless steels have been implanted with molybdenum ions (Mo"+, 100 keV, 2.5 x 10"1"6 atoms cm"-"2). The implanted material has been characterized by XPS and RBS. The implanted region has a thickness of #approx# 1000 A with a maximum molybdenum concentration of #approx# 9 at.% Mo located at #approx# 210 A from the surface. The effects of implanted molybdenum on the passivation of the alloy in 0.5 M H_2SO_4 have been investigated by electrochemistry and XPS. After XPS analysis the samples were transferred without exposure to air into a glove-box with an inert atmosphere. The electrochemical behaviour of the alloy is significantly modified by the implanted molybdenum. The major effect is that the activation peak disappears. A bilayer structure (outer hydroxide/inner oxide) of the passive film is observed for both the implanted and non-implanted alloys and the thicknesses of the films are similar. On the implanted alloy the outer ...
1991-10-01
International Nuclear Information System (INIS)
We report the discovery of an active galactic nucleus (AGN) pair in the interacting galaxy system IRAS 20210+1121 at z = 0.056. An XMM-Newton observation reveals the presence of an obscured (N _H #approx# 5 x 10"2"3 cm"-"2), Seyfert-like (L _2_-_1_0_k_e_V = 4.7 x 10"4"2 erg s"-"1) nucleus in the northern galaxy, which lacks unambiguous optical AGN signatures. Our spectral analysis also provides strong evidence that the IR-luminous southern galaxy hosts a Type 2 quasar embedded in a bright starburst emission. In particular, the X-ray primary continuum from the nucleus appears totally depressed in the XMM-Newton band as expected in the case of a Compton-thick absorber, and only the emission produced by Compton scattering ('reflection') of the continuum from circumnuclear matter is seen. As such, IRAS 20210+1121 seems to provide an excellent opportunity to witness a key, early phase in the quasar evolution predicted by the theoretical models of ...
2010-10-20
Kbeta-to-Kalpha X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of Ti(x)Ni(1-x) (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi (109)Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured Kbeta-to-Kalpha X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other element and/or the rearrangement of electrons between 3d and 4s, ...
2010-01-28
International Nuclear Information System (INIS)
K?-to-K? X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of TixNi1-x (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi 109Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured K?-to-K? X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other element and/or the rearrangement of electrons between 3d and 4s, 4p states of ...
2010-06-01
Energy Technology Data Exchange (ETDEWEB)
With the aim of studying the magnetic properties of reduced-dimensionality magnetic systems we have patterned 250 nm- and 500 nm-size square elements on Fe/NiO layers by 30 keV Ga{sup +} focused ion beam (FIB) milling, varying beam current and pixel dwell time. By high resolution scanning electron microscope (SEM) imaging and atomic force microscopy (AFM) analysis we found that island size decreases from the nominal value by increasing the beam current and features sharpness improves on increasing the dwell time. The top surface of the isolated features has a pronounced edge bending which may be as high as 9 nm with respect to the flat inner area of the island and decreases as dwell time grows. By varying the ion fluence we found that such a shape is related to a surface swelling effect occurring at low ion fluence in the irradiated areas. The swelling-related damage at the edges is expected to influence the magnetic properties of the patterned ...
2005-04-01
International Nuclear Information System (INIS)
With the aim of studying the magnetic properties of reduced-dimensionality magnetic systems we have patterned 250 nm- and 500 nm-size square elements on Fe/NiO layers by 30 keV Ga"+ focused ion beam (FIB) milling, varying beam current and pixel dwell time. By high resolution scanning electron microscope (SEM) imaging and atomic force microscopy (AFM) analysis we found that island size decreases from the nominal value by increasing the beam current and features sharpness improves on increasing the dwell time. The top surface of the isolated features has a pronounced edge bending which may be as high as 9 nm with respect to the flat inner area of the island and decreases as dwell time grows. By varying the ion fluence we found that such a shape is related to a surface swelling effect occurring at low ion fluence in the irradiated areas. The swelling-related damage at the edges is expected to influence the magnetic properties of the patterned ...
2005-04-01
Study of iodine migration in zirconia using stable and radioactive ion implantation
Energy Technology Data Exchange (ETDEWEB)
The large uranium fission cross section leading to iodine and the behaviour of this element in the cladding tube during energy production and afterwards during waste storage is a crucial problem, especially for {sup 129}I which is a very long half-life isotope (T=1.59 x 10{sup 7} yr). Since a combined external and internal oxidation of the zircaloy cladding tube occurs during the reactor processing, iodine diffusion parameters in zirconia are needed. In order to obtain these data, stable iodine atoms were first introduced by ion implantation into zirconia with an energy of 200 keV and a dose equal to 8 x 10{sup 15} at cm{sup -2}. Diffusion profiles were measured using 3 MeV alpha-particle Rutherford backscattering spectrometry at each step of the annealing procedure between 700 C and 900 C. In such experiments a reduced iodine concentration was observed, which correlated to a diffusion-like process. Similar analysis has been performed using ...
1998-03-01
Spectroscopy of "8"8Sr with the "8"7Sr(n,#gamma#) and "8"7Sr(d,p) reactions
International Nuclear Information System (INIS)
The #gamma#-ray spectrum emitted after thermal neutron capture in "8"7Sr was studied at the ILL high flux reactor with pair- and intrinsic Ge-spectrometers. 661 transitions were assigned to the reaction "8"7Sr(n,#gamma#)"8"8Sr and 205 of them were placed into a "8"8Sr level scheme of 47 levels. This represents 88% of the observed intensity. The level energies were determined with a precision of better than 22 ppm; the neutron binding energy was determined as 11 112.69 (22) keV. To aid the analysis high resolution particle spectra of the reaction "8"7Sr(d,p)"8"8Sr were measured at 20 MeV deuteron energy with the Munich Q3D spectrometer. 85 states were observed with this reaction. The data helped to establish newly found levels and to differentiate between primary and secondary transitions in the (n,#gamma#) data. The observed level densities and primary transition strengths are compared with statistical model predictions and non-statistical ...
Measurement of $\\phi$(1020) meson leptonic width with CMD-2 detector at VEPP-2M Collider
The $\\phi$(1020) meson leptonic width has been determined from the combined analysis of 4 major decay modes of the resonance ($\\phi\\to K^+ K^-,K^0_LK^0_S,\\pi^+\\pi^-\\pi^0,\\eta\\gamma$) studied with the CMD-2 detector at the VEPP-2M $e^+e^-$ collider. The following value has been obtained: $\\Gamma(\\phi\\to e^+e^-) = 1.235\\pm 0.006\\pm 0.022$ keV. The $\\phi(1020)$ meson parameters in four main decay channels have been also recalculated: $B(\\phi\\to K^+K^-) = 0.493\\pm 0.003\\pm 0.007$, $B(\\phi\\to K_LK_S) = 0.336\\pm 0.002\\pm 0.006$, $B(\\phi\\to\\pi^+\\pi^-\\pi^0) = 0.155\\pm 0.002\\pm 0.005$, $B(\\phi\\to\\eta\\gamma) = 0.0138\\pm 0.0002\\pm 0.0002$.
2010-01-01
Lifetime and {ital g}-factor measurements of the 11{sup {minus}} isomer in {sup 92}Tc
Energy Technology Data Exchange (ETDEWEB)
The half-life ({ital T}{sub 1/2}) and {ital g} factor of the 2002 keV 11{sup {minus}} isomer in the odd-odd nucleus {sup 92}Tc produced by the pulsed heavy-ion reaction {sup 68}Zn({sup 28}Si,{ital p}3{ital n}){sup 92}Tc have been measured using time differential perturbed angular distribution method. The measured {ital T}{sub 1/2} value is 3.15(20) ns. From the observed spin precession frequency {omega}{sub {ital L}} of a {sup 92}Tc recoil implanted into a ferromagnetic Ni host, we obtain the {ital g} factor to be 0.806(20). The measured value of the {ital g} factor is in good agreement with a shell model analysis carried out using {pi}({ital p}{sub 1/2}{ital g}{sub 9/2}) and {nu}({ital p}{sub 1/2}{ital g}{sub 9/2}) orbitals for the proton particles and neutron holes outside the {sup 88}Sr core. {copyright} {ital 1996 The American Physical Society.}
1996-12-01
High variability in Vela X-1: giant flares and off states
We investigate the spectral and temporal behavior of the high mass X-ray binary Vela X-1 during a phase of high activity, with special focus on the observed giant flares and off states. INTEGRAL observed Vela X-1 in a long almost uninterrupted observation for two weeks in 2003 Nov/Dec. The data were analyzed with OSA 7.0 and FTOOLS 6.2. We derive the pulse period, light curves, spectra, hardness ratios, and hardness intensity diagrams, and study the eclipse. In addition to an already high activity level, Vela X-1 exhibited several intense flares, the brightest ones reaching a maximum intensity of more than 5 Crab in the 20-40 keV band and several off states where the source was no longer detected by INTEGRAL. We determine the pulse period to be 283.5320+/-0.0002 s, which is stable throughout the entire observation. Analyzing the eclipses provided an improvement in the ephemeris. Spectral analysis of the flares indicates that there appear to be ...
2008-01-01
Direct patterning of gold oxide thin films by focused ion-beam irradiation
International Nuclear Information System (INIS)
For direct writing of electrically conducting connections and areas into insulating gold oxide thin films a scanning Ar"+ laser beam and a 30 keV Ga"+ focused ion beam (FIB) have been used. The gold oxide films are prepared by magnetron sputtering under argon/oxygen plasma. The patterning of larger areas (dimension 10-100 #mu#m) has been carried out with the laser beam by local heating of the selected area above the decomposition temperature of AuO_x(130-150 C). For smaller dimensions (100 nm to 10 #mu#m) the FIB irradiation could be used. With both complementary methods a reduction of the sheet resistance by 6-7 orders of magnitude has been achieved in the irradiated regions (e.g. with FIB irradiation from 1.5 x 10"7#OMEGA#/#square# to approximately 6 #OMEGA#/#square#). The energy-dispersive X-ray analysis (EDX) show a considerably reduced oxygen content in the irradiated areas, and scanning electron microscopy (SEM), as well as atomic force ...
2000-09-01
Direct evidence of the recombination of silicon interstitial atoms at the silicon surface
Energy Technology Data Exchange (ETDEWEB)
In this experiment, a Si wafer containing four lightly doped B marker layers epitaxially grown by CVD has been implanted with 100 keV Si{sup +} ions to a dose of 2 x 10{sup 14} ions/cm{sup 2} and annealed at 850 deg. C for several times in an RTA system in flowing N{sub 2}. TEM and SIMS analysis, in conjunction with a transient enhanced diffusion (TED) evaluation method based on the kick-out diffusion mechanism, have allowed us to accurately study the boron TED evolution in presence of extended defects. We show that the silicon surface plays a key role in the recombination of Si interstitial atoms by providing the first experimental evidence of the resulting Si{sub int}s supersaturation gradient between the defect region and the surface. Our results indicate an upper limit of about 200 nm for the surface recombination length of Si interstitials at 850 deg. C in a N{sub 2} ambient.
2004-02-01
Direct evidence of the recombination of silicon interstitial atoms at the silicon surface
International Nuclear Information System (INIS)
In this experiment, a Si wafer containing four lightly doped B marker layers epitaxially grown by CVD has been implanted with 100 keV Si"+ ions to a dose of 2 x 10"1"4 ions/cm"2 and annealed at 850 deg. C for several times in an RTA system in flowing N_2. TEM and SIMS analysis, in conjunction with a transient enhanced diffusion (TED) evaluation method based on the kick-out diffusion mechanism, have allowed us to accurately study the boron TED evolution in presence of extended defects. We show that the silicon surface plays a key role in the recombination of Si interstitial atoms by providing the first experimental evidence of the resulting Si_i_n_ts supersaturation gradient between the defect region and the surface. Our results indicate an upper limit of about 200 nm for the surface recombination length of Si interstitials at 850 deg. C in a N_2 ambient.
2004-02-01
Process for maintaining coal proportions in a coal blend
A process is described for maintaining the proportions of each coal in a coal blend at a desired level. The process involves (1) making a spectral analysis, preferably by infrared spectrometry, of at least one sample of the coal blend, the sample having known desired proportions of each coal, (2) making a spectral analysis of the coal blend sample of unknown proportions of each coal, (3) comparing the spectral analyses of steps (1) and (2), and (4) upon noting a significant difference between the spectral analyses of steps (1) and (2), making adjustments to achieve a final coal blend having proportions of each coal closer to those of the blend of known desired proportions of each coal. The relationship of the aromatic to aliphatic groupings is preferably determined by spectral analysis of each coal sample. This process is particularly useful on-line in the production of blast furnace coke of high ...
1983-01-25
We construct a sample of low-redshift Ly-alpha emission-line selected sources from GALEX grism spectroscopy of nine deep fields to study the role of Ly-alpha emission in galaxy populations with cosmic time. Our final sample consists of 122 (142) sources selected in the redshift interval z=0.195-0.44 (z=0.65-1.25) from the FUV (NUV) channel. We classify the Ly-alpha sources as AGNs if high-ionization emission lines are present in their UV spectra and as galaxies otherwise. These classifications are broadly supported by comparisons with X-ray and optical spectroscopic observations. We classify additional sources as AGNs using line widths for our Ly-alpha emitter (LAE) analysis. Defining the GALEX LAE sample in the same way as high-redshift LAE samples, we show that LAEs constitute only about 5% of NUV-continuum selected galaxies at z~0.3. We also show that they are less common at z~0.3 than they are at ...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
A Tm{sup 3+}- Ho{sup 3+} -codoped single crystal of monoclinic BaY{sub 2}F{sub 8} has been characterized by means of high resolution FTIR spectroscopy in the wave number range 2000-24000 cm{sup -1} and in the temperature range 9-300 K. The energy level schemes of the two lanthanide ions as determined by the optical absorption spectra is presented, analyzed, and fitted within a single ion Hamiltonian model. The very small energy separation (about 0.6-1.6 cm{sup -1}) measured between the first and second sublevels of the ground state manifolds for both the ions is in line with the theoretical predictions. The impurity-phonon coupling is put into evidence by the thermally induced line shift and broadening, and by the detection of vibronic replicas of a few lines. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)
2005-01-01
High resolution Fourier transform spectroscopy and crystal-field analysis in Tm,Ho:BaY_2F_8
International Nuclear Information System (INIS)
A Tm"3"+- Ho"3"+ -codoped single crystal of monoclinic BaY_2F_8 has been characterized by means of high resolution FTIR spectroscopy in the wave number range 2000-24000 cm"-"1 and in the temperature range 9-300 K. The energy level schemes of the two lanthanide ions as determined by the optical absorption spectra is presented, analyzed, and fitted within a single ion Hamiltonian model. The very small energy separation (about 0.6-1.6 cm"-"1) measured between the first and second sublevels of the ground state manifolds for both the ions is in line with the theoretical predictions. The impurity-phonon coupling is put into evidence by the thermally induced line shift and broadening, and by the detection of vibronic replicas of a few lines. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)
2005-01-01
Energy Technology Data Exchange (ETDEWEB)
The object of this research is the evaluation of the performance of ultra high speed relays (UHSR's) used for protection of a-c transmission lines. For purposes of this report, these are relays whose response time is less than a quarter of a cycle of the 60 Hz wave (i.e. 4.167 ms.). To identify relaying schemes that may comply with this definition, a literature survey was undertaken. The selected relays were studied in detail and modeled on a digital computer. A theoretical description of these relays is presented. Records of real transient data as well as of simulated data were used as input to the digital models of relays. The real data were recorded by means of monitoring stations connected to the Florida Power and Light Company transmission lines. The simulated data were obtained by modeling the relevant parts of the utility's transmission system using a University of British Columbia simplified version of the well known ...
1984-01-01
International Nuclear Information System (INIS)
The authors have previously identified a small-cell lung cancer cell line (NCI-H209) that expresses an aberrant, underphosphorylated form of the retinoblastoma protein RB1. Molecular analysis of RB1 mRNA from this cell line revealed a single point mutation within exon 21 that resulted in a nonconservative amino acid substitution (cysteine to phenylalanine) at codon 706. Stable expression of this mutant RB1 cDNA in a human cell line lacking endogenous RB1 demonstrated that this amino acid change was sufficient to inhibit phosphorylation. In addition, this cysteine-to-phenylalanine substitution also resulted in loss of RB1 binding to the simian virus 40 large tumor and adenovirus E1A transforming proteins. These results confirm the importance of exon 21 coding sequences and suggest that the cysteine residue at codon 706 may play a role in achieving a specific protein conformation essential for ...
International Nuclear Information System (INIS)
A semi-empirical relation which can be used to determine the total attenuation cross sections of samples containing H, C, N and O in the energy range 145-1332 keV has been derived based on the total attenuation cross sections of several sugars, amino acids and fatty acids. The cross sections have been measured by performing transmission experiments in a narrow beam good geometry set-up by employing a high-resolution hyperpure germanium detector at seven energies of biological importance such as 145.4 keV, 279.2 keV, 514 keV, 661.6 keV, 1115.5 keV, 1173.2 keV and 1332.1 keV. The semi-empirical relation can reproduce the experimental values within 1-2%. The total attenuation cross sections of five elements carbon, aluminium, titanium, copper and zirconium measured in the same experimental set-up at the energies mentioned ...
2006-09-28
Sub-0.1 #mu#m line fabrication by Focused ion beam and columnar structural Se-Ge resist
International Nuclear Information System (INIS)
As a method to enhance the sensitivity (S) of an inorganic resist for focused-ion-beam (FIB), lithography, sub-0.1 #mu#m patterning properties of a columnar structural #alpha#-Se_7_5Ge_2_5 resist have been investigated using 30 keV low-energy Ga"+-FIB exposure and CF_4 reactive-ion etching (RIE). development. The Se_7_5Ge_2_5 thin films were 60 .deg. and 80 .deg. -obliquely deposited on Si substrate and parts of the films were annealed for several minutes at the glass transition temperature (T_g=#approx#220 .deg. C). Columnar structures with the angles of approximately 40 .deg. and 65 .deg. are observed in 60 .deg. and 80 .deg. -obliquely deposited films, respectively, and they disappear after annealing. Despite the disappearance of the columnar structures, a critical decrease in thickness is not observed. For the FIB exposures with a beam diameter of #approx#0.1#mu#m and around the threshold dose, the negative-type fine patterns with linewidth of about ...
1998-11-01
FABRICATION OF BISMUTH NANOWIRE DEVICES USING FOCUSED ION BEAM MILLING
International Nuclear Information System (INIS)
In this work, a focused ion beam (FIB) milling process has been developed to fabricate 50 nm Bi nanowire and transistor structures using FEI-200 dual beam FIB system. For the fabrication, 50 nm bismuth film was thermally evaporated through EBL patterned PMMA windows onto SiO_2 substrates with pre-defined contact pads. Bi nanowire widths ranging from 30 nm to 100 nm have been successfully fabricated by milling out unwanted areas using 30 KeV Ga+ ion beam. A single-pixel-line ion beam blanking technique has been utilised to fabricate Bi nanowire as small as 30 nm in diameter and few micrometers long. In order to form good ohmic contacts for sub 50 nm bismuth nanowires, a drill-and-fill process has been developed using FIB to sputter away the surface oxide of bismuth after the in-situ platinum nanowire contacts deposition. To our knowledge, this is the first time a focused ion beam process has been used to fabricate bismuth nanowire. The ...
2009-07-23
Energy Technology Data Exchange (ETDEWEB)
The study of audible noise from high voltage transmission lines and a high voltage transformer station was conducted in three parts. Part 1 consisted of long-term measurement and statistical analysis by computer reduction of audible noise as a result of corona discharge from high voltage transmission lines and the associated weather conditions which contribute to this noise. Recommendations are given concerning further computer programming in order to improve the statistical reliability of corona noise presence and reduce the degree of background noise contamination of the present results. Part 2 consisted of categorizing and cataloguing of corona noise spectra from long-term measurements on 550, 735 and 765 kV transmission lines and to provide a library of such sounds on magnetic tape to be used in the ongoing study of corona noise. Twenty-five different corona sound spectra have been identified and ...
1986-11-01
Field-effect research at the High Voltage Transmission Research Center
Energy Technology Data Exchange (ETDEWEB)
This report presents information obtained during five different studies of field effects from high voltage transmission lines performed at EPRI's High Voltage Transmission Research Center. The first study is the development of a methodology for the evaluation of the expected frequency of occurrence of specific short-term effects of spark discharges and induced currents caused by overhead high voltage transmission lines. The methodology is divided into the analysis of the expected frequency of occurrence of situations in which induction effects may occur, and the analysis of the expected severity of the effect. The second study is of the electric field in the surface and on the immediate proximity of the strands of stranded conductors used for overhead high voltage lines. In particular, the cases of deformations of stranded conductors, caused by air expansion or by popped ...
1991-02-01
Approximate analysis of non-uniform gas flow through layered burdens
Energy Technology Data Exchange (ETDEWEB)
An approximate analyzing model was developed to predict the azimuth of zigzag streamline, the distribution ratio between two neighboring layers and the radial distribution among the layers of the gas passing through the shaft of blast furnace loaded in layers. The theoretical basis of the approximate analysis is composed of the material balance derived from the assumption that any stream line surrounded with two streamlines is isolated and no material transfer occurs through the tube wall, and of the energy theory that the stream tube and passage are formed so that the total pressure drop in the whole system is the minimum. The effects of the apparent angle of repose between two layers, the packing volume and the passage resistance on the non-uniform flow in the layer were evaluated on the basis of the model. The result calculated by the approximate analysis agrees with the result by the numerical ...
1988-02-01
Energy Technology Data Exchange (ETDEWEB)
Using standard brass alloy samples, an approach to reduce the laser-induced breakdown spectroscopy measurement uncertainty was tested and proved. Two important parameters for plasma characterization, the plasma temperature and the electron density, were applied to minimize the signal uncertainties due to uncontrollable experimental parameter variations. Results show that for the pulse-to-pulse analysis, the signal fluctuations can be significantly reduced by utilizing the plasma characteristic information. The major source for the single pulse fluctuations is the redistribution of the characteristic line at different temperatures according to the Boltzmann distribution under LTE. The change of the degree of ionization also contributes to the signal fluctuations. For the multi-pulse analysis, due to the nonlinear relationship between the plasma temperature and the line intensity, it is not applicable to ...
2010-07-15
Energy Technology Data Exchange (ETDEWEB)
This paper describes potentials on fuel economy and NO{sub x} exhaust emissions of a series hybrid urban bus system equipped with a ceramic gas turbine engine (CGT). The simulating program developed in-house was used to analyze influences of several parameters of each main components of the hybrid vehicle system on the performance of the bus running on the modified bus driving cycle. The basic data used in this analysis for a CGT was derived from the results of 'the Automotive 100kW CGT Project' of Japan. A dynamic response of a CGT-Generator rotating system was very much improved by introducing of 'Assisting system' in which the generator was used as an acceleration-deceleration assisting device when much acceleration or deceleration was needed. This system would make a CGT operate along the optimum operating line (fuel minimum line) even under the unsteady driving conditions. This ...
2000-03-20
EDP in shaft construction. [Electronic data processing
Energy Technology Data Exchange (ETDEWEB)
Lining shafts and placing them in a given strata needs extensive computation. Therefore, it is natural that the use of electronic computing and of numerical methods in this mining area started early. For shafts being sunk in non-stable water-bearing strata the deformations and stresses of the freezing wall are analysed. The complex system of an outer lining in the shaft sinking stage is designed with regard to the elastic support of the strata. In cases of strata-embedded systems the tubbing liner can be shaped as the loads require. Here analysis of safety against buckling is very important. If a sliding shaft is built as a composite construction, there are advantages in determining the distribution of the material by numerical methods. The analysis of stability is possible only by numerical methods and could not be solved otherwise. The Finite Element Method proves itself as a very general tool to ...
1987-02-05
Determination of small amounts of elements by radionuclide X-ray fluorescence analysis
International Nuclear Information System (INIS)
The determination of small amounts of elements by radionuclide X-ray fluorescence analysis is described. Samples containing 5x10"-"4 to 5x10"-"6 g of elements were fixed on a suitable carrier. For a coaxial configuration a low-energy source of the #gamma#/X type was used, namely an annular "2"4"1Am/Ag source with an activity of 7.4x10"8 s"-"1 (20 mCi), and for a configuration with side reflection source of the #beta#/X type was used, namely "1"4"7Pm/Sm with the activity of Pm(OH)_3 approximately 3.7x1O"1"0 s"-"1 (1 Ci). Cs, Ba, La, Pr, Nd, and Ag were determined by means of the Ksub(#alpha#) line and Hg, W, Er, and Pr by means of the Lsub(#alpha#) line. For all elements studied a detection limit of the order of 10"-"7 g was achieved. (author).
1975-01-01
International Nuclear Information System (INIS)
A case study is presented where an integrated, ecologically relevant exposure assessment is presented for a polluted lowland river. Using partial least squares regression of latent structures (PLS), an analysis of the impact of two effluents on physico-chemical water quality measures, macroinvertebrate and diatom communities, and in situ bioassay responses with four different test species are combined into an integrative exposure assessment. Bioassays focussed on growth and condition related endpoints, because they are key functional processes of organisms and populations. Integrating these multiple lines of evidence, we were able to discriminate among the impact of both effluents, link changes in physico-chemical water quality with bioassay endpoints and ecological quality of the ecosystem, and address the importance of integrating all information into one exposure assessment framework. The bioassays under field conditions indicated that most ...
2004-11-01
The investigations on K and L X-ray fluorescence parameters of gold compounds
British Library Electronic Table of Contents (United Kingdom)
The study aimed to determine the chemical effects on the K and L X-ray intensity ratios and the K and L X-ray production cross sections for gold compounds. The K shell fluorescence yields and L shell average yields were also investigated. The samples were excited by 59.5keV ?-rays from an 241Am annular radioactive source and 123.6keV ?-rays from a 57Co annular radioactive source. K and L X-rays emitted from samples were counted by an Ultra-LEGe detector with a resolution of 0.150keV at 5.9keV. The experimental values were compared with theoretical, the semi-empirical and other experimental values.
2010-01-01
The Canonical Seyfert Spectrum: The Implications of OSSE ...
... In a HEAO 1 study of active galaxies, principally Seyfert 1s, in the 2, 165 keV energy range, Rothschild et al. ... As discussed by Rothschild et al. ...
2011-05-14
On penetration effect in M1 component of 70.45 keV #gamma#-transition in "1"7"7Ta
International Nuclear Information System (INIS)
... gamma radiation l conversion m conversion mev range 10-100 mixing ratio
1987-04-14
Electric and magnetic dipole transitions in odd-proton rare-earth nuclei
International Nuclear Information System (INIS)
... gamma cascades kev range 10-100 lifetime lutetium 171 lutetium 173 lutetium
1972-05-01
Using condition monitoring for maintenance, control of hydro plants
Energy Technology Data Exchange (ETDEWEB)
Electric utilities are actively seeking ways of optimizing the economics of their operations by improving productivity and reducing time and money spent on maintenance. Iberdrola, a Spanish utility, is using advanced machine condition-monitoring technology to centralize control and maintenance of its hydropower projects as a means of achieving those goals. The company is using a blend of technologies to supervise their projects from a regional control center. The monitoring scheme makes use of data from on-line, machine-condition monitors, displays from in-plant audio asnd video equipment, and analysis from the control center`s SCADA system.
1994-12-31
Three-dimensional data processing for time resolved gamma-ray spectrometry
International Nuclear Information System (INIS)
A new acquisition and evaluation procedure has been introduced for the measurement of time-dependent processes in gamma-ray spectrometry, in order to extract more information, including half-lives, from the data recorded during acquisition and to enable a more comprehensive analysis of the results. These advanced, off-line data evaluation techniques improve the selectivity and the background subtraction and make it possible to estimate the important analytical parameters (e.g., half-lives) more accurately than with the usual decay curve fitting method. (author)
Subsidence model of spoil bank surface
Energy Technology Data Exchange (ETDEWEB)
Evaluates a mathematical model that describes subsidence of spoil banks in surface brown coal mines. The model is based on the results of geodetic surveys carried out in 1974-1985. Twelve spoil banks from 4 to 61 m high were considered. Ground subsidence and deformation along 12 measuring lines and 6 measuring networks were measured. Ground subsidence during a period of 18 to 241 months was evaluated using regression analysis. The mathematical model considered effects of spoil bank design (number and thickness of rock layers), rock mechanical and physical properties and service time. 6 refs.
1989-01-01
Secondary stresses on transmission tower structures
Energy Technology Data Exchange (ETDEWEB)
The power industry is moving toward the use of high-voltage transmission lines on tall, flexible towers. These towers are designed for heavier loadings than were previous towers, but the secondary effects of tower displacement tend to be ignored in the present day tower analysis. This paper examines the secondary effects from the large displacement of flexible towers, reviews the secondary stresses arising from joint rigidity and member continuity, and examines the reliability of tower strength predicted by the ASCE design guidelines. More realistic tower test acceptance criteria and a more reliable tower design methodology are suggested.
1984-06-01
Position-sensitive spectroscopy of 252Cf fission fragments
International Nuclear Information System (INIS)
The fission fragments from spontaneous fission of 252Cf have been measured with the spectrometric and position-sensitive semiconductor pixel detector Medipix2. Fragments are identified by pattern recognition of clusters generated in the Medipix2 pixel matrix sensor upon heavy particle hit. From analysis of cluster area, the distribution of kinetic energy of fission fragments is obtained. Together with a novel USB readout interface, the Medipix2/USB system operates as active nuclear emulsion in single-quantum and on-line tracking mode.
2007-05-11
PPAR action in insulin resistance unraveled by metabolomics: potential clinical implications.
ABSTRACT: Metabolomic analysis will provide the next large set of clues to further our understanding of human health and disease. A recent study has elucidated the significant differences in the metabolomes of adipocytes, serum and an adipocyte cell line after activation of two nuclear receptors, peroxisome proliferator activated receptor ?/? (PPAR?/?) and PPAR?. These findings hold great promise for explaining fundamental differences in the mechanisms of PPAR agonists and for identifying targets for the treatment of diabetes.See related research article: http://genomebiology.com/2011/12/8/R75. PMID:21861850
2011-08-23
Energy Technology Data Exchange (ETDEWEB)
The Purex process and the fluorescence spectrometry are first recalled, then uranyl fluorescence is studied in a pure nitric medium without other elements to establish a theoretical model, allowing the description of uranium fluorescence signal with a general equation. The influence of different parameters (temperature, inhibitors, dynamic quenching of iron and cerium) is investigated to develop the model. A quantitative analysis method without addition of reagents is proposed to validate the model.
1992-02-25
Long cylindrical mirror sections with an 'Alliptical' cross- section and an interfoci distance of approximately 1 m can be produced by means of diamond fly cutting. However, because of the finite tool radius, the generated profile is basically not an ellipse, but an equidistant ellipse or 'Allipse'. By numerical ray tracing analysis two unique conjugated 'A-points' can be found that are optically nearly equivalent with pure elliptical focal points. A reversed modeling procedure is used to predict the optimum machine configuration for producing just the required ellipse sections. Optical figure quality, focal line position and straightness are tested by a simple deflectometer set-up.
1999-09-01
Corrosion 2003. Conference papers on CD-ROM
Energy Technology Data Exchange (ETDEWEB)
Papers are presented under 38 symposia. Subjects included reinforced concrete, protective coatings and linings, cathodic/anodic protection, chemical cleaning of boilers, managing corrosion with plastics, water treatment, HRSG boiler tube failure analysis, corrosion in oil and gas production, corrosion in petroleum refining and gas, processing, pipelines and tanks, high temperature materials, chemical process industry, aerospace equipment, materials technology developments for incinerators and waste fuel-fired processors, materials and corrosion in fossil-fuels conversion and combustion, corrosion in nuclear systems, marine corrosion, building systems, corrosion mechanisms, corrosion inhibitors and corrosion monitoring and measurement.
2003-07-01
Analysis of WWER 440 SG primary collector bolted joint damage
Energy Technology Data Exchange (ETDEWEB)
The susceptibility of CHN35VT-VD and 08CH18N10T stainless steels to stress corrosion cracking in water environment, simulating water solution found in threaded holes, was investigated using rising load line displacement tests of precracked C(T) specimens. To judge the role of oxidant on stress corrosion cracking of both stainless steels, the effect of dissolved oxygen content (fully deaerated water, water aerated at the beginning of the test) was studied. 7 refs.
1997-12-31
In situ texture analysis under applied load
International Nuclear Information System (INIS)
The in-situ measurement of a crystallographic texture is a special type of a non-destructive measurement, which need special equipments. Due to the high photon flux and the excellent brilliance high energetic synchrotron radiations are a fantastic tool particular in fast experimentation. Moreover, a high penetration power allows the investigation of standard tensile sample of the DIN-norm. A loading device with a power up to 20 kN was installed at the hard wiggler beamline BW5 (HASYLAB-DESY) to perform in-situ strain and in-situ texture analysis. Using 100keV X-rays one gets short wavelength so that a 2D image-plate detector offers a wide range of diffraction pattern within the first 10 degree in 2 theta. Thermal neutron is another radiation with a high penetration power, which is the standard method for global texture analysis of bulk samples. As an example rectangular extruded Mg- Az31 was investigated by an in-situ. ...
Rapid yield learning through optical defect and electrical test analysis
Energy Technology Data Exchange (ETDEWEB)
As semiconductor device density and wafer area continue to increase, the volume of in-line and off-line data required to diagnose yield-limiting conditions is growing exponentially. To manage this data in the future, analysis tools will be required that can automatically reduce this data to useful information, e.g., by assisting the engineer in rapid root-cause diagnosis of defect generating mechanisms. In this paper, the authors describe a technology known as Spatial Signature Analysis (SSA) and its application to both optically-detected defect data as well as electrical test (e-test) bin data. The results of a validation study are summarized that demonstrate the effectiveness of the SSA approach on optical defect wafermaps through field-testing at three semiconductor manufacturing sites on ASIC, DRAM and SRAM products. This method has been extended to analyze and interpret electrical test data and to ...
1998-02-01
DEFF Research Database (Denmark)
Antisense- or RNAi-mediated suppression of the biosynthesis of nutritionally inferior storage proteins is a promising strategy for improving the amino acid profile of seeds. However, the potential pleiotropic effects of this on interconnected pathways and the agronomic quality traits need to be addressed. In the current study, a transcriptomic analysis of an antisense C-hordein line of barley was performed, using a grain-specific cDNA array. The C-hordein antisense line is characterized by marked changes in storage protein and amino acid profiles, while the seed weight is within the normal range and no external morphological irregularities were observed. The results of the transcriptome analysis showed excellent correlation with data on changes in the relative proportions of storage proteins and amino acid composition. The antisense line had a lower C-hordein level and ...
2007-01-01
DEFF Research Database (Denmark)
Antisense- or RNAi-mediated suppression of the biosynthesis of nutritionally inferior storage proteins is a promising strategy for improving the amino acid profile of seeds. However, the potential pleiotropic effects of this on interconnected pathways and the agronomic quality traits need to be addressed. In the current study, a transcriptomic analysis of an antisense C-hordein line of barley was performed, using a grain-specific cDNA array. The C-hordein antisense line is characterized by marked changes in storage protein and amino acid profiles, while the seed weight is within the normal range and no external morphological irregularities were observed. The results of the transcriptome analysis showed excellent correlation with data on changes in the relative proportions of storage proteins and amino acid composition. The antisense line had a lower C-hordein level and ...
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
The primary objectives of this study were to test two utility analysis models, the Cascio-Ramos Estimate of Performance in Dollars (CREPID) model and Godkewitsch financial utility analysis model and to determine their appropriateness as tools for evaluating training. This study was conducted in conjunction with Philadelphia Electric Company's Nuclear Training Group. Job performance of nuclear maintenance workers was assessed to document the impact of the training program. Assessment of job performance covered six job performance themes. Additionally, front-line nuclear maintenance supervisors were interviewed to determine their perceptions of the nuclear maintenance training. A comparison of supervisor's perceptions and outcomes of the utility analysis models was made to determine the appropriateness of utility analysis as quantitative tools for evaluating the ...
1991-01-01
Wetting failure and contact line dynamics in a Couette flow
Liquid-liquid wetting failure is investigated in a two-dimensional Couette system with two immiscible fluids of arbitrary viscosity. The problem is solved exactly using a sharp interface treatment of hydrodynamics (lubrication theory) as a function of the capillary number, viscous ratio and separation of scale, i.e. slip length versus macroscopic scale of the system. The existence of critical velocities, above which no stationary solutions are found, is analyzed in detail in terms of the relevant parameters of the system. Comparisons with existing analysis for other geometries are also carried out. A numerical method of analysis is also presented, based on diffuse interface models obtained from multiphase extensions of the lattice Boltzmann equation (LBE). Sharp interface and diffuse interface models are quantitatively compared face to face indicating the correct limit of applicability of the diffuse interface models.
2008-01-01
Vertical array receptions of the Heard Island transmissions
Energy Technology Data Exchange (ETDEWEB)
The Heard Island Feasibility Test (HIFT) demonstrated that coded acoustic signals could be detected at ranges up to 18,000 km with currently available source technology. This paper describes one component of the HIFT where a large aperture vertical line array was deployed to record the signals transmitted from Heard Island. We have performed four analysis Of the VLA receptions, of the Heard Island signals. All four suggest the presence of higher order modes. The frequency- vertical wavenumber analysis and the modal beamforming indicate that mode 3 has the highest amplitude while the modal fitting suggests that made 5--6 are largest. It is difficult to resolve the differences since the SNR at the VLA, nearly 18,000 km with a transmission loss of around 145 dB, is quite low. Individual arrivals could not be distinguished because of the long integration time necessitated by the low SNR.
1993-03-23
Vacuum system pump down analysis
Energy Technology Data Exchange (ETDEWEB)
My assignment on the SP-100 Vacuum Vessel Vacuum System Team was to perform a transient pump down analysis for the vacuum vessel that will house the SP-100 reactor during testing. Pump down time was calculated for air and helium. For all cases the proposed vacuum system will be able to pump down the vessel within the required time. The use of a larger rotary piston pump (DUO250) improves the pump down time by 35 minutes and therefore should be considered. The 6-inch duct for the roughing line is optimal, however, because all cases are well below the 24 hour time frame, the 4-inch duct is sufficient. The use of the single turbomolecular pump during pump down is sufficient. A pump down with helium in the vessel and a helium inleakage delays the time to achieve the base pressure marginally and is acceptable.
1990-08-01
The SUERC AMS laboratory after 3 years
British Library Electronic Table of Contents (United Kingdom)
The new SUERC AMS Laboratory was described at AMS-9. Since then there have been technological developments, added and improved analysis capability, the formation of additional complementary groups, the purchase of another instrument, and many samples measured. Be, C, Al, Cl, Ca and I-AMS are established with measured species changing weekly. Full-terminal potential running is now routine and 5MV is proving sufficient for all species. Ion detection and evaluation has also been improved by the use of even thinner detector windows as necessary and a more powerful on-line data analysis system. Routine radiocarbon measurement is to 4permil reproducibility at middling current and graphite samples of as little as 100mg C can be accommodated. Even smaller samples can be measured as CO2 using He ca...
2007-01-01
British Library Electronic Table of Contents (United Kingdom)
Background and purpose: The aims of this study were to investigate the anti-cancer activity of SZ-685C, an anthracycline analogue isolated from marine-derived mangrove endophytic fungi, and to explore the molecular mechanisms underlying such activity. Experimental approach: The effect of SZ-685C on the viability of cancer cell lines was investigated using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) assay. SZ-685C-induced apoptosis was assessed by Annexin V-fluorescein isothiocyanate/propidium iodide staining, terminal deoxynucleotidyl transferase-mediated dUTP nick end labelling assay and analysis of caspase activation. The effect of SZ-685C on the Akt/FOXO pathway was studied using Western blotting analysis, and the in vivo anti-tumour efficacy was examined in ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
A back-propagation neural network technique is used at JET to extract plasma parameters like ion temperature, rotation velocities or spectral line intensities from charge exchange (CX) spectra. It is shown that in the case of the C VI CX spectra, neural networks can give a good estimation (better than +-20% accuracy) for the main plasma parameters (Ti, V{sub rot}). Since the neural network approach involves no iterations or initial guesses the speed with which a spectrum is processed is so high (0.2 ms/spectrum) that real time analysis will be achieved in the near future. 4 refs., 8 figs.
1994-07-01
Initial airborne CO{sub 2} DIAL measurements: Discussion of results and data analysis considerations
Energy Technology Data Exchange (ETDEWEB)
A detailed discussion of airborne CO{sub 2}, DIAL measurements obtained from the first joint N-ABLE field campaign at INEL is presented. System performance characteristics, including return signal strength, averaging statistics, and temporal correlation as well as multi-line DIAL spectral data are discussed. In particular, we review data acquisition and analysis strategies pertinent to chemical detection from a moving platform, such as range determination and correction, and return signal processing (waveform vs. box-car integration, baseline correction). We also report observed effects and variations due to near-field light scattering, pointing and tracking stability, and stack-release plume dynamics.
1997-07-01
British Library Electronic Table of Contents (United Kingdom)
In this paper we demonstrate the capabilities of our ArcGIS-based software development that includes an adapted database system and a GIS tool for storage, combined analysis and visualization of leveling data and interferometric synthetic aperture radar (SAR) deformation measurements. Preprocessed remote sensing image data are stored with metadata that include all processing routines and parameters. This allows reproduction and traceability of all processing steps. Deformation monitoring is supported through data searching and selection based on a variety of criteria. A methods toolbox allows spatio-temporal analyses for points, lines and areas (e.g. subsidence basins) in a graphical manner.
2011-01-01
Fault location observability analysis and optimal meter placement based on voltage measurements
British Library Electronic Table of Contents (United Kingdom)
Various transmission line fault location algorithms have been proposed in the past depending on measurements available. These methods evince that if a sufficient number of meters are placed in a power network to record the fault measurements, then the fault location can be reliably estimated. A relevant question to ask may be: how many meters are sufficient in order to derive a reliable and unique fault location estimate for a given network? This paper addresses this question by defining and performing the fault location observability analysis. An optimal meter placement scheme is proposed for determining the optimal locations to place meters so as to make the system observable while minimizing the required number of meters to reduce costs. The proposed method is especially useful for powe...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
WELLOG is a system of programs developed at the Earth Science Laboratory to be used to digitize well logs and perform some analysis and plotting of the data. Multiple logs can be plotted side by side for correlation analysis and up to three logs can be plotted in a cross plot. Data entry and editing functions are also provided by the programs. This system of well log interpretation programs is presently operating on the University of Utah UNIVAC 1108 computer. Digitizing of well logs is accomplished by an old model CALMA (off-line) digitizer. Those parts of WELLOG that handle the digitized data tapes are extremely machine dependent. The parts of WELLOG that produce the plots and handle the data beyond the digitized data tape are more portable.
1980-03-01
Analysis of even harmonics generation in an isolated electric power system
British Library Electronic Table of Contents (United Kingdom)
Harmonics bred from loads are mainly odd order because the current waveforms have half-wave symmetry. Since the even harmonics are negligibly small, they generally are not measured in electric power systems. However, even harmonics were measured at a 500/275/154 kV substation in Hokuriku Electric Power Company after a transmission line fault was corrected. The even harmonics caused malfunctions of protective digital relays because the relays used 4th harmonics at the input filter as the automatic supervisory signal. This paper describes mechanisms of generation of the even harmonics by comparing the measured waveforms with the ATP-EMTP simulation results. Analysis of these results has clearly shown that there are three different mechanisms of generation of even harmonics. The first mechani...
2009-01-01
An analysis of selected atmospheric icing events on test cables
Energy Technology Data Exchange (ETDEWEB)
In cold countries, the design of transmission lines and communication networks requires the knowledge of ice loads on conductors. Atmospheric icing is a stochastic phenomenon and therefore probabilistic design is used more and more for structure icing analysis. For strength and reliability assessments, a data base on atmospheric icing is needed to characterize the distributions of ice load and corresponding meteorological parameters. A test site where icing is frequent is used to obtain field data on atmospheric icing. This test site is located on the Mt. Valin, near Chicoutimi, Quebec, Canada. The experimental installation is mainly composed of various instrumented but non-energized test cables, meteorological instruments, a data acquisition system, and a video recorder. Several types of icing events can produce large ice accretions dangerous for land-based structures. They are rime due to in-cloud icing, glaze caused by freezing rain, wet ...
1996-12-01
International Nuclear Information System (INIS)
Three major monomeric hemoglobins have been isolated from the erythrocytes of Glycera dibranchiata. Their importance to structure-function studies of heme proteins lies in the fact that they have been shown to possess an exceptional amino acid substitution. In these proteins, the E-7 position is occupied by leucine rather than the more common distal histidine. This substitution alters the polarity of the heme ligand binding environment compared to myoglobin. Due to this, the G. dibranchiata monomer hemoglobins are attracting much attention. However, until now no purity criterion has been developed. Here the authors demonstrate that, for all of the Glycera momomer hemoglobins, multiple line patterns are shown on high-voltage isoelectric focusing (IEF) gels. Most of these lines are shown to be a consequence of heme-related phenomena and can be understood on the basis of changes in oxidation and ligation state of the heme iron. The multiple ...
Generation of human cortical neurons from a new immortal fetal neural stem cell line
International Nuclear Information System (INIS)
Isolation and expansion of neural stem cells (NSCs) of human origin are crucial for successful development of cell therapy approaches in neurodegenerative diseases. Different epigenetic and genetic immortalization strategies have been established for long-term maintenance and expansion of these cells in vitro. Here we report the generation of a new, clonal NSC (hc-NSC) line, derived from human fetal cortical tissue, based on v-myc immortalization. Using immunocytochemistry, we show that these cells retain the characteristics of NSCs after more than 50 passages. Under proliferation conditions, when supplemented with epidermal and basic fibroblast growth factors, the hc-NSCs expressed neural stem/progenitor cell markers like nestin, vimentin and Sox2. When growth factors were withdrawn, proliferation and expression of v-myc and telomerase were dramatically reduced, and the hc-NSCs differentiated into glia and neurons (mostly glutamatergic and GABAergic, as well as ...
2007-02-01
UK PubMed Central (United Kingdom)
We have established a cartilaginous fish cell line [Squalus acanthias embryo cell line (SAE)], a mesenchymal stem cell line derived from the embryo of an elasmobranch, the spiny dogfish...Full Text Available
2007-01-23
Penetration effect in the M1 component of "1"7"7Ta #gamma#-transition with energy of 70.45 keV
International Nuclear Information System (INIS)
The magnetic #beta#-spectrometer of the #pi# #sq root#2 type with 0.07% pulse resolution is used to measure the intensities of interval conversion electrons on L- and M-subshells of 70.45 keV "1"7"7 Ta gamma-transition. The results are analyzed and the values of mixing parameter #sigma#(E2/M1) and penetration parameter #lambda# are obtained.
Improved FNAL linac beam choppers
Energy Technology Data Exchange (ETDEWEB)
A discussion is presented of the 750-KeV chopper experience with both proton and negative ion beams and the ability of these systems to tailor the Linac beam to the diverse requirements of its users; normal accelerator injection, neutron therapy beam, and electron cooling experiments. This flexibility plus a cleaner beam pulse, improved thyratron operation, and mechanical modularity are the results of recent improvements. Additional benefits have been increased reliability and ease of service to the 750-KeV chopper. 3 refs.
1981-06-01
Gamma-ray spectra from neutron capture on /sup 87/Sr
Energy Technology Data Exchange (ETDEWEB)
The gamma-ray spectrum following neutron capture on /sup 87/Sr was measured at 3 neutron energies: E/sub n/ = thermal, 2 keV, and 24 keV. Gamma rays were detected in a three-crystal Ge(Li)-NaI-NaI pair spectrometer. Gamma-ray intensities deduced from these spectra by spectral unfolding are presented.
1981-07-01
ON-LINE MONITORING OF FLUE GAS DESULFURIZATION ...
... Title : ON-LINE MONITORING OF FLUE GAS DESULFURIZATION SCRUBBER CORROSION WITH ELECTROCHEMICAL TECHNIQUES. ...
1986-11-01
Mais Tallinna-Helsingi laevaliinile Nordic Jet Line / Koit Luus
AS Nordic Jet Line uus katamaraan Tallinna-Helsingi laevaliinil
1998-01-01
Design of a kW, DC Magnetically Contained Electrothermal ...
... magnetic containment field lines which is zero on the center line of the toroidal containment tube and increases in magnitude with ...
1988-07-01
Transient enhanced diffusion from decaborane molecular ion implantation
Energy Technology Data Exchange (ETDEWEB)
Transient enhanced diffusion (TED) from implantation of 5thinspkeVthinspB{sub 10}H{sub 14} and 0.5 keV B ions has been quantified and compared for nominal boron doses of 10{sup 14} and 10{sup 15}thinspcm{sup {minus}2}. Boron diffusivity during annealing was extracted from secondary ion mass spectroscopy depth profiles of diffused marker layers in boron doping-superlattices and the actual implanted B dose was independently measured by nuclear reaction analysis. Comparable enhancements were observed from both ions. Transmission electron microscopy analysis revealed that both boron- and decaborane-implanted samples were amorphized at a nominal 10{sup 15}thinspcm{sup {minus}2}thinspB dose. A comparison with data from low energy Si implants revealed a similar dependence of diffusivity enhancement on implant dose. These findings are consistent with the understanding that TED is caused by the interstitial supersaturation resulting ...
1998-10-01
Transient enhanced diffusion from decaborane molecular ion implantation
International Nuclear Information System (INIS)
Transient enhanced diffusion (TED) from implantation of 5keVB_1_0H_1_4 and 0.5 keV B ions has been quantified and compared for nominal boron doses of 10"1"4 and 10"1"5cm"-"2. Boron diffusivity during annealing was extracted from secondary ion mass spectroscopy depth profiles of diffused marker layers in boron doping-superlattices and the actual implanted B dose was independently measured by nuclear reaction analysis. Comparable enhancements were observed from both ions. Transmission electron microscopy analysis revealed that both boron- and decaborane-implanted samples were amorphized at a nominal 10"1"5cm"-"2B dose. A comparison with data from low energy Si implants revealed a similar dependence of diffusivity enhancement on implant dose. These findings are consistent with the understanding that TED is caused by the interstitial supersaturation resulting from a number of excess interstitials approximately equal to the ...
1998-10-01
Status of the WAND (Waste Assay for Nonradioactive Disposal) project as of July 1997
Energy Technology Data Exchange (ETDEWEB)
The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole system and to perform the data analysis. WAND system minimum detectable activities (MDAs) for point sources ...
1998-03-01
Reevaluation of 58Ni and 60Ni Resonance Parameters in the Energy Range Thermal to 800 keV
Energy Technology Data Exchange (ETDEWEB)
The previous 58Ni and 60Ni set of resonance parameters (ENDF/B-VII-0, JEFF-3, etc.) was based on the SAMMY analysis of Oak Ridge National Laboratory neutron transmission, scattering cross section and capture cross section measurements by C. M. Perey et al. The present results were obtained by adding to the SAMMY experimental data base the capture cross sections measured recently at the Oak Ridge Linear Electron Accelerator by Guber et al. and the Geel Electron Linear Accelerator very high-resolution neutron transmission measurements performed by Brusegan et al. A complete resonance parameter covariance matrix (RPCM) was obtained from the SAMMY analysis of the experimental database. The data sets were made consistent, when needed, by adjusting the neutron energy scales, the normalization coefficients, and the background corrections. The RPCM allows the calculation of the cross section uncertainties due mainly to statistical errors in the ...
2009-09-01
Energy Technology Data Exchange (ETDEWEB)
The previous {sup 58}Ni and {sup 60}Ni set of resonance parameters (Endf/B7.O, Jeff-3, etc.) was based on the SAMMY analysis of Oak Ridge National Laboratory neutron transmission, scattering cross section and capture cross section measurements by C.M. Perey et al. The present results were obtained by adding to the SAMMY experimental database the capture cross sections measured recently at the Oak Ridge Linear Electron Accelerator by Guber et al. and the Geel Electron Linear Accelerator and very high-resolution neutron transmission measurements performed by Brusegan et al. A complete resonance parameter covariance matrix (RPCM) was obtained from the SAMMY analysis of the experimental database. The data sets were made consistent, when needed, by adjusting the neutron energy scales, the normalization coefficients, and the background corrections. The RPCM allows the calculation of the cross section uncertainties due mainly to statistical errors in ...
2009-07-01
Energy Technology Data Exchange (ETDEWEB)
The object and the purpose of the present work was to develop, to assemble and to start running a new TOF (time of flight) mass spectrometer for imaging SNMS analytic which is optimized for the analysis of highly molecular secondary ions. The most important purpose was the characterization of the TOF mass spectrometer. The obtained mass spectra of indium, tantalum and silver clusters reflect the excellent properties of the TOF mass spectrometer for the detection of large clusters with good detection efficiency up to masses of 16000 amu. The possibility of the deflection of selected saturated atom and cluster peaks serves for further improvement of the detection efficiency for large molecules. The accessible mass resolution was determined to be of the order of m/{delta}m=1000 in the high mass region. Numerous measurements were carried out to characterize the useful yield of this spectrometer. For a best possible adaptation of the TOF mass spectrometer for the ...
2006-12-21
Observed energy dependence of Fano factor in silicon at hard X-ray energies
Energy Technology Data Exchange (ETDEWEB)
An experimental evaluation of the Fano factor F in silicon at hard X-ray energies (5.9-136.5 keV) has been performed by means of a low-noise, high charge collection efficiency silicon drift detector with on-chip electronics. A dependence of F from the detector temperature as well as from the energy of the X-ray photons has been found. Assuming a pair creation energy equal to 3.64 eV, at +20 deg. C the F factor was observed to vary from 0.124{+-}0.006 at 5.9 keV up to 0.159{+-}0.002 at 122 keV. At -35 deg. C, the change of F with respect to the photon energy was less remarkable but nevertheless statistically significant, from 0.123{+-}0.002 at 5.9 keV up to 0.134{+-}0.001 at 122 keV. To our knowledge, the present results represent the first experimental evidence of an energy dependence of the Fano factor in silicon at hard X-ray energies.
1999-03-01
0--30 keV low-energy focused ion beam system
Energy Technology Data Exchange (ETDEWEB)
Low-energy focused ion beam (FIB) is a useful tool for shallow doping, gas-assisted etching, and other uses to minimize substrate damage in semiconductor device fabrication. The possibility to form a finely FIB of low energy under 1 keV was suggested in the investigations on the retarding mode in electron optical systems. The abilities of the simplest type of retarding mode FIB column are examined here. The optical properties are calculated for the corresponding model and some images are observed with Ga/sup +/ ion beams <0.3 ..mu..m in diameter for beam energies, 10, 5, and 1 keV, using a retarding mode one-lens FIB system. 1-keV and 100-eV Ga/sup +/ FIB was implanted to Ga/As substrate, and the defects are analyzed by deep-level transient spectroscopy. The defect concentration for 100 eV was < (1)/(5) that for 1000 keV.
1988-05-01
0--30 keV low-energy focused ion beam system
International Nuclear Information System (INIS)
Low-energy focused ion beam (FIB) is a useful tool for shallow doping, gas-assisted etching, and other uses to minimize substrate damage in semiconductor device fabrication. The possibility to form a finely FIB of low energy under 1 keV was suggested in the investigations on the retarding mode in electron optical systems. The abilities of the simplest type of retarding mode FIB column are examined here. The optical properties are calculated for the corresponding model and some images are observed with Ga"+ ion beams <0.3 #mu#m in diameter for beam energies, 10, 5, and 1 keV, using a retarding mode one-lens FIB system. 1-keV and 100-eV Ga"+ FIB was implanted to Ga/As substrate, and the defects are analyzed by deep-level transient spectroscopy. The defect concentration for 100 eV was < (1)/(5) that for 1000 keV.
Methods of reducing magnetic field near the transmission lines
International Nuclear Information System (INIS)
Due to biological effects of magnetic fields of high voltage transmission lines and induced effects on has pipe line, telecommunication system and interference with sensitive electronic equipment, many effort have been done to reduce transmission lines magnetic fields and several ideas have been introduced. In this paper we review three methods: phase split, shielded and compacted line methods. With aid of a developed software programme these methods are then applied to transmission lines and the results are analyzed.
2003-01-01
Energy Technology Data Exchange (ETDEWEB)
Corona from bare conductors of electrical overhead power lines is studied in this article. Its origin, as well as, its bad influences over communication systems are both studied, yet. Line`s models are defined, in order to be able the examination of Corona on line`s cables. Formulas for the surface electrical gradient calculations are shown. (author) 2 refs.
1993-12-01
Terra Nova tow-out poised as next East Coast event
Energy Technology Data Exchange (ETDEWEB)
This spring, Newfoundland will send off a floating production, storage and offloading (FPSO) vessel to the offshore Terra Nova field. The Terra Nova will proceed southeast through Bull Arm, then northeast out of Trinity Bay, then heads southeast to the Jeanne d'Arc Basin on the Grand Banks. The Terra Nova is expected to produce 115,000 barrels of oil per day for six years, when it reaches full capacity. The consortium, headed by Petro-Canada as senior ownership partner and operator, built an environment protection program into every aspect of the project. Some of the features of the environment protection program include glory holes excavated on the ocean floor for the protection of production equipment from icebergs, to a flare stack on the platform, which has four legs to provide stability in rough seas. The FPSO was designed to withstand sea ice, icebergs, and severe winter storms. Flow lines are also protected, and in the event that a ...
2001-01-15
Extended observation and analysis of the first overtone spectrum of solid parahydrogen
Energy Technology Data Exchange (ETDEWEB)
The first overtone spectrum of solid parahydrogen with various low ortho impurity levels has been studied in detail using a White-type external multireflection system. For the Q{sub 2{l_arrow}0}(0) transition the authors have observed the fully resolved threefold splitting due to the crystal field effect. Furthermore, the authors have obtained a rich satellite spectrum associated with the transitions Q{sub 2{l_arrow}0}(0) and Q{sub 2{l_arrow}0}(1) at different ortho-H{sub 2} contents revealing information about the ortho-H{sub 2} pair interaction in the second vibrationally excited state of the hydrogen molecule. A preliminary analysis and assignment of these satellite transitions will be presented. Another point of study was the spectral region around 8300 cm{sup -1}, where the double transitions of the type Q{sub 1{l_arrow}0}(n) + Q{sub 1{l_arrow}0}(n{prime}) (n, n{prime} = 0,1) are located. The most remarkable features here are the Q{sub 1{l_arrow}0}(l) + Q{sub ...
1996-12-31
Doppler lidar mounted on a wind turbine nacelle - UPWIND deliverable D6.7.1
Energy Technology Data Exchange (ETDEWEB)
A ZephIR prototype wind lidar manufactured by QinetiQ was mounted on the nacelle of a Vestas V27 wind turbine and measurements of the incoming wind flow towards the rotor of the wind turbine were acquired for approximately 3 months (April - June 2009). The objective of this experiment was the investigation of the turbulence attenuation induced in the lidar measurements. In this report are presented results from data analysis over a 21-hour period (2009-05-05 12:00 - 2009-05-06 09:00). During this period the wind turbine was not operating and the line-of-sight of the lidar was aligned with the wind direction. The analysis included a correlation study between the ZephIR lidar and a METEK sonic anemometer. The correlation analysis was performed using both 10 minutes and 10 Hz wind speed values. The spectral transfer function which describes the turbulence attenuation, which is induced in the lidar ...
2010-12-15
X-ray dosimetry of TlGaSe_2 single crystals
International Nuclear Information System (INIS)
TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. X-ray conductivity coefficients K_#sigma# characterising X-ray sensitivity of investigated crystals are determined as the relative ...
In a recent survey of the stellar populations of LINERS and LINER/HII Transition Objects (TOs) we identified a numerous class of nuclei which stand out because of their conspicuous 10^8-9 yr populations. These objects were called ``Young-TOs'', since they all have TO-like emission line ratios. In this paper we investigate the radial variations of spectral properties in Low Luminosity AGN. Our analysis is based on high S/N, 3500-5500 A, long-slit spectra for 47 galaxies. The data probe distances of typically up to 850 pc from the nucleus with a resolution of ~ 100 pc and S/N ~ 30. Stellar population gradients are mapped by the radial profiles of absorption line equivalent widths and colours along the slit. These variations are further analyzed by means of a decomposition of each spectrum in terms of template galaxies representative of very young (<= 10^7 yr), intermediate age (10^8-9 yr) and old (10^10 yr) populations. ...
2004-01-01
Post-column reaction detector for platinum(II) antieoplastic agents
Energy Technology Data Exchange (ETDEWEB)
The development and evaluation of a post-column reaction detector sensitive to platinum(II) complexes is presented in which sodium bisulfite is used as the derivatizing agent with potassium dichromate as an activating agent. The influences of mobile phase changes (i.e., pH, organic modifiers, electrolytes), oxygen, metal ions, and order of reagent addition on reaction kinetics and product yield are defined and used in optimization of detector response. Detection at lambda/sub max/ 290 nm results in an on-line post-column sensitivity of 40-60 ng/mL for selected cis-dichloroplatinum complexes and a sensitivity of 300-1200 ng/mL for four (substituted)-malonato-platinum complexes. The reaction detector is used to monitor the kinetics of aquation of cisplatin (CDDP) and to quantitate CDDP degradation in plasma. As the sensitivity for CDDP in plasma is comparable to that achieved from high pressure liquid chromatography (HPLC) effluent ...
1984-03-01
In-pile measurements of fuel rod deformation and verification of the finite element model FEMAXI
International Nuclear Information System (INIS)
For safety evaluations and licensing procedures, fuel rod performance is predicted through model calculations. Due to the complexity of fuel rod performance and the insufficient availability of experimental data, such calculations necessarily reflect inaccuracies and conservatism. For verification and development of more realistic models and submodels, acquisition of reliable on-line data on fuel rod performance characteristics is imperative. The present paper describes the instruments and equipment applied in the Halden Reactor for on-line measurements of fuel rod and assembly power and power distribution, and fuel rod axial and diameter deformation. Recent results from evaluation of such fuel rod deformation measurements, covering fuel rods with different designs, subjected to various modes of operation, including startup ramps, steady state, and power shock, are presented. It is also shown how these data are used for verification and ...
1976-09-13
Finite element analysis of pipe whip restraint behavior under jet thrust forces
International Nuclear Information System (INIS)
Many types of pipe whip restraints are installed to protect the structural components from the anticipated pipe whip phenomena of high energy lines in nuclear power plants. It is necessary to investigate these phenomena accurately in order to design the pipe whip restraints properly and/or to evaluate the acceptability of the pipe whip restraint design. Various research programs have been conducted in many countries to develop analytical methods and to verify the validity of the methods. In this study, various types of finite elements in ANSYS, the general purpose finite element computer grogram, was used to simulate the postulated pipe whips to obtain impact loads and the calculted results were compared with the specific experimental results from the sample pipe whip test for the U-chaped pipe whip restraints. Some calculational models, having the gap element or the spring element between the pipe whip restraint and the pipe line, give ...
Energy Technology Data Exchange (ETDEWEB)
Anisotropy has been investigated using S-wave as a technique for detecting fractures. In this study, fundamental experiments were carried out with slightly changing the measuring conditions at a place where anisotropy was expected. This paper describes the fundamental data acquisition of anisotropy analysis using S-wave, and a part of the results. The experiments were conducted on the agricultural road in Yamadera district, Matsuyama-machi, Yamagata Prefecture. Two flat unpaved roads meeting at right angles were used as traverse lines. In this place, several reflection surfaces were certainly detected by P-wave, and anisotropy of S-wave was confirmed from the velocity of refracted wave of S-wave. Data were processed for individual traverse lines meeting at right angles. Firstly, signal sweeping, correlation, and vertical superposition were made. Six kinds of data were prepared, i.e., three-component receiving records of ...
1996-10-01
Comparative study of computational model for pipe whip analysis
International Nuclear Information System (INIS)
Many types of pipe whip restraints are installed to protect the structural components from the anticipated pipe whip phenomena of high energy lines in nuclear power plants. It is necessary to investigate these phenomena accurately in order to evaluate the acceptability of the pipe whip restraint design. Various research programs have been conducted in many countries to develop analytical methods and to verify the validity of the methods. In this study, various calculational models in ANSYS code and in ADLPIPE code, the general purpose finite element computer programs, were used to simulate the postulated pipe whips to obtain impact loads and the calculated results were compared with the specific experimental results from the sample pipe whip test for the U-shaped pipe whip restraints. Some calculational models, having the spring element between the pipe whip restraint and the pipe line, give reasonably good transient responses of the restraint ...
1993-08-15
Accretion onto Supermassive Black Holes in Quasars: Learning from Optical/UV Observations
Accretion processes in quasars and active galactic nuclei are still poorly understood, especially as far as the connection between observed spectral properties and physical parameters is concerned. Quasars show an additional degree of complexity compared to stars that is related to anisotropic emission/obscuration influencing the observed properties in most spectral ranges. This complicating factor has hampered efforts to define the equivalent of an Hertzsprung-Russel diagram for quasars. Even if it has recently become possible to estimate black hole mass and Eddington ratio for sources using optical and UV broad emission lines, the results are still plagued by large uncertainties. Nevertheless, robust trends are emerging from multivariate analysis of large spectral datasets of quasars. A firm observational basis is being laid out by accurate measurements of broad emission line properties especially when the source ...
2006-01-01
A sensitive submillimetre survey of Broad Absorption Line quasars
Using the SCUBA bolometer array on the JCMT, we have carried out a submillimetre survey of Broad Absorption Line quasars (BALQs). The sample has been chosen to match, in redshift and optical luminosity, an existing benchmark 850um sample of radio-quiet quasars, allowing a direct comparison of the submm properties of BAL quasars relative to the parent radio-quiet population. We reach a submm limit 1.5mJy at 850um, allowing a more rigorous measure of the submm properties of BAL quasars than previous studies. Our submm photometry complements extensive observations at other wavelengths, in particular X-rays with Chandra and mid-infrared with Spitzer. To compare the 850um flux distribution of BALQs with that of the non-BAL quasar benchmark sample, we employ a suite of statistical methods, including survival analysis and a novel Bayesian derivation of the underlying flux distribution. Although there are no strong grounds for rejecting the null ...
2006-01-01
The study of technical error analysis on BMD using DEXA
International Nuclear Information System (INIS)
This study was conducted to search for the type of technical error in DEXA (dual-energy X-ray absorptiometry) and the effect of error to measurement of BMD. The changes of BMD (g/cm2, T-score) by patients information (Age, Weight, Height, Manopause age) input error and Confirming ROI error were investigated. Using spine phantom, we canned 10 times by age (5, 10), weight (10, 20 kg), height (5, 10 cm), manopause age (5, 10) increase and decrease respectively. Scanning region (L-spine, femur, Forearm) of 10 patients was calculated by changing ROI respectively. Analysis of difference for mean (precision 1%) were carried out. There error of patient information (Age, Weight, Height, Manopause age) was not changed differently. In confirming ROI, the BMD and T-score of L-spine involving T-12 was decreased to 0.063 g/cm2, 0.3 and involving L-5 increased to 0.077 g/cm2, 0.5. In narrowing 1 cm of vertical line of ROI, the BMD and T-score decreased to ...
2006-12-01
The Cross-Calibration of Swift-BAT and Fermi-GBM via Correlative Spectral Analysis of GRBs
We report on recent inter-calibration studies featuring Swift's Burst Alert Telescope (BAT) and Fermi's Gamma-ray Burst Monitor (GBM) based upon correlated observations of GRBs 080804 and 080810, via their resultant joint spectral analysis. Swift's intrinsic multi-wavelength instrumentation and dynamical response complement Fermi's superior energy range. The addition of BAT's spectral response will (i) facilitate in-orbit GBM detector response calibration, (ii) augment Fermi's low energy sensitivity, (iii) enable ground-based follow-up efforts of Fermi GRBs, and (iv) help identify a subset of GRBs discovered via off-line GBM data analysis, for an annual estimate of ~30 GRBs. The synergy of BAT and GBM augments previous successful joint spectral fit efforts by enabling the study of peak photon energies (Epeak), while leveraging the over eleven energy decades afforded by Fermi's Large Area Telescope (LAT), in conjunction with ...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
This report concerns investigations in the title conducted by 8 groups of National Institute of Radiological Sciences (NIRS) during the period of 1998-2000. The groups are for investigation of: Effects of p53 tumor suppressor gene in radiation-induced leukemia, Role of atm-gene in dose rate effect of ionizing radiation, Function of DNA-dependent protein kinase catalytic subunit (DNA-PK{sub cs}), Functional complementation of radiation-sensitive mutant M10 cell line by human XRCC4 cDNA expression, Role of radiation-induced apoptosis in digital defects in embryonic mice, Functional analysis of S-phase specific novel nuclear protein NP95 by gene targeting, Role of chemokine in T cell development and lymphomagenesis, and establishment of production techniques of gene-modified mice using embryonic stem cells for genetic analysis of radiation-sensitive genes. The groups describe summaries of their studies and published original ...
2002-03-01
Calibration-Free Laser-Induced Breakdown Spectroscopy: State of the art
Energy Technology Data Exchange (ETDEWEB)
The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal ...
2010-01-15
Calibration-Free Laser-Induced Breakdown Spectroscopy: State of the art
International Nuclear Information System (INIS)
The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
The core bypass phenomenon of borated water injected through direct vessel injection (DVI) nozzles in APR1400 (Advanced Power Reactor 1400MWe) during main steam line break (MSLB) accidents with a reactor coolant pump (RCP) running mode has been simulated using a two-channel and one-dimensional system analysis model code (MARS), and a three-dimensional computational fluid dynamics (CFD) code (FLUENT). A visualization experiment has also been performed using a scaled-down model of the APR1400. The MARS analysis has predicted a serious core bypass phenomenon of borated water, while the CFD analysis has shown results opposite to the MARS results. The CFD analysis has shown that the flow pattern in the downcomer is fully three-dimensional and that vortex flow structures are formed near the cold legs so that the borated water might pass without difficulty into the high flow region of the ...
2007-04-15
The effects of energy non-monochromaticity of "1"1B ion beams on "1"1B diffusion
International Nuclear Information System (INIS)
We have shown that energy contamination introduced by ion beam deceleration technology that is used to increase the beam currents available for low energy boron implants, can affect fabricated junctions adversely. A 4 keV "1"1B beam is extracted and retarded by a potential of -3.5 keV for 0.5 keV "1"1B implantation, or by a potential of -3.8 keV for 0.2 keV "1"1B implantation. Intentional beam contamination was introduced by turning off the retarding potential to allow the 4 keV "1"1B ions to irradiate Si wafers directly. The percentage of contamination, at levels of 0.1%, 0.2% and 0.3% was introduced. Rapid thermal annealing of all the implanted samples was performed under N_2 ambient at 1050 deg. C for 1 s. The dopant tail profiles themselves are not significant if the contamination levels are low. However, the much higher damage level coming from high energy ...
2005-08-01
Requirements and guidelines for NSLS experimental beam line vacuum systems: Revision A
Energy Technology Data Exchange (ETDEWEB)
Requirements are provided for NSLS beam line front ends and vacuum interlocks. Guidelines are provided for UHV beam line vacuum systems, including materials, vacuum hardware (pumps, valves, and flanges), acoustic delay lines and beam line fast valves, instrumentation, fabrication and testing, and the NSLS cleaning facility. Also discussed are the design review for experimenters' equipment that would be connected to the NSLS and acceptance tests for any beam line to be connected with the ring vacuum. Also appended are a description of the acoustic delay line as well as the NSLS vacuum standards and NSLS procedures. (LEW)
1986-10-01
DECAY OF Ta$sup 177$ AND Lu$sup 177$ TO LEVELS IN Hf$sup 17$$sup 7$
The decays of Ta/sup 177/ and Lu/sup 177/ to levels in vestigated with beta spectrometers, NaI(Tl) gamma spectrometers, and fast coincidence and angular correlation techniques. Energy levels in Hf/sup 177/ were characterized according to their energy (kev), the Nilsson asymptotic quantum numbers (Nn/sub 2/ LAMBDA ), the total angular momentum and its component along the symmetry axis (I,K), and the parity ( pi ) as follows: 0STA5I4 7/2, 7/2-!; 112.97STA514 9/2, 7/ 2-!; 249.7STA5I4 11/2, 7/1-!; 32l.34STA624 9/2, 9/2+1; 447.9STA624 11/2, 585.8STA642 7/2, 3/2+1; 509.0STA5I2 5/2, 5/1-1; 605.5STA512 7/2, 5/2-!; 746.04STA633 7/2, 7/2+1; 848.2STA 633 9/2, 7/2+1; and 1058.38STA503 7/2, 7/2-!. The levels at 447.9, 488.8, and 585.8 kev are tentative. The spins and parities were uniquely determined by angular correlation and internal conversion data for the levels at 746.0 and 848.2 kev, asof the levels at 0, ...
1961-10-15
International Nuclear Information System (INIS)
In summary, a scaling analysis of a water-cooled Reactor Cavity Cooling System (RCCS) system was performed based on generic information on the RCCS design of PBMR. The analysis demonstrates that the water-cooled RCCS can be simulated at the ANL NSTF facility at a prototypic scale in the lateral direction and about half scale in the vertical direction. Because, by necessity, the scaling is based on a number of approximations, and because no analytical information is available on the performance of a reference water-cooled RCCS, the scaling analysis presented here needs to be 'validated' by analysis of the steady state and transient performance of a reference water-cooled RCCS design. The analysis of the RCCS performance by CFD and system codes presents a number of challenges including: strong 3-D effects in the cavity and the RCCS tubes; simulation of turbulence in flows ...
Progress of negative-ion based NBI system for JT-60U
Energy Technology Data Exchange (ETDEWEB)
The operation of the negative ion based NBI system for JT-60U has been progressed since 1996. Most of the efforts in the operation for increasing beam power and energy have been concentrated to get over the troubles, caused by surge energy at the moment of the accelerator break-down, in the ion sources and high voltage power supplies. The ion source for the N-NBI, so far, has accelerated negative ion beams of 14.3 A at 380 keV with deuterium and 18.5 A at 360 keV with hydrogen against the target of 22 A. The neutral beam power injected into JT-60U has already reached 5.2 MW at 350 keV for 0.7 sec with deuterium. (author)
1998-07-01
Negative-ion based NBI system for JT-60U
Energy Technology Data Exchange (ETDEWEB)
A 500 keV negative-ion based NBI system is under construction for NB current drive and plasma core heating in high density plasma in JT-60U. Part of the beamline and the high voltage power supply required for a verification test of an ion source was completed in March 1995. After having done a high potential test of the power supply, the negative-ion generation and acceleration tests started in June 1995 aiming at deuterium beams of 500 keV, 22A. In initial experiment, deuterium negative-ion beams of 410 keV, 6.1A (2.5 MW) for 0.2 sec, so far, have been achieved. This is the world highest D{sup {minus}} current and negative ion beam power. The construction of the total system will be completed by the beginning of 1996, and the beam injection will start in March 1996.
1995-12-31
International Nuclear Information System (INIS)
The half-value thicknesses, linear and mass attenuation coefficients of biological samples such as bone, muscle, fat and water have been measured at 140, 364 and 662keV ?-ray energies by using the ATOMLABTM-930 medical spectrometer. The ?-rays were obtained from 99mTc, 131I and 137Cs ?-ray point sources. Also theoretical calculations have been performed in order to obtain the half-value thicknesses and, mass and linear attenuation coefficients at photon energies 0.001keV-20MeV for bone, muscle and water samples. The calculated value and the experimental results of this work and the other results in literature are found to be in good agreement.
2006-11-01
Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr
Energy Technology Data Exchange (ETDEWEB)
Neutron capture ..gamma..-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.
1985-01-15
Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr
International Nuclear Information System (INIS)
Neutron capture #gamma#-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.
1984-09-10
Energy Technology Data Exchange (ETDEWEB)
K{beta}-to-K{alpha} X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of Ti{sub x}Ni{sub 1-x} (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi {sup 109}Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured K{beta}-to-K{alpha} X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other element and/or the rearrangement of electrons ...
2010-06-15
Energy Technology Data Exchange (ETDEWEB)
K{beta}-to-K{alpha} X-ray intensity ratios of Ti, Cr, Fe and Co in pure metals and in Cr{sub 0.26}Fe{sub 0.74}, Cr{sub 0.80}Co{sub 0.20} and Ti{sub 0.80}Cr{sub 0.20} alloys have been measured following excitation by 59.54 keV {gamma}-rays from a 7400 MBq (200 mCi) {sup 241}Am point-source. The valence electronic structure of Ti, Cr, Fe and Co in the samples have been evaluated by the comparison of the measured K{beta}-to-K{alpha} intensity ratios with the results of multiconfiguration Dirac-Fock calculations performed for various electronic configurations of these metals. The 3d-electron populations obtained for pure metallic Ti, Cr, Fe and Co agree well with the results of band structure calculations of Papaconstantopoulos (Handbook of band structure of elemental solids, Plenum Press, New York, 1986). Our analysis indicates significant increase of 3d-electron population of Ti, Cr and Fe in the alloys with respect to the pure metals, except for ...
2002-10-01
International Nuclear Information System (INIS)
K#beta#-to-K#alpha# X-ray intensity ratios of Ti, Cr, Fe and Co in pure metals and in Cr_0_._2_6Fe_0_._7_4, Cr_0_._8_0Co_0_._2_0 and Ti_0_._8_0Cr_0_._2_0 alloys have been measured following excitation by 59.54 keV #gamma#-rays from a 7400 MBq (200 mCi) "2"4"1Am point-source. The valence electronic structure of Ti, Cr, Fe and Co in the samples have been evaluated by the comparison of the measured K#beta#-to-K#alpha# intensity ratios with the results of multiconfiguration Dirac-Fock calculations performed for various electronic configurations of these metals. The 3d-electron populations obtained for pure metallic Ti, Cr, Fe and Co agree well with the results of band structure calculations of Papaconstantopoulos (Handbook of band structure of elemental solids, Plenum Press, New York, 1986). Our analysis indicates significant increase of 3d-electron population of Ti, Cr and Fe in the alloys with respect to the pure metals, except for Cr in ...
2002-10-01
Energy Technology Data Exchange (ETDEWEB)
The studies of {sup 137}Cs and {sup 239+240}Pu distributions in surface seawater at South China Sea within the Exclusive Economic Zone (EEZ) of Peninsular Malaysia were carried out in June 2008. The analysis results will serve as additional information to the expanded baseline data for Malaysia's marine environment. Thirty locations from extended study area were identified in the EEZ from which large volumes of surface seawater samples were collected. Different co-precipitation techniques were employed to concentrate cesium and plutonium separately. A known amount of {sup 134}Cs and {sup 242}Pu tracers were used as yield determinant. The precipitate slurry was collected and oven dried at 60 {sup o}C for 1-2 days. Cesium precipitate was fine-ground and counted using gamma-ray spectrometry system at 661.62 keV, while plutonium was separated from other radionuclides using anion exchange, electrodeposited and counted using alpha ...
2010-09-15
SLAROM-UF: Ultra fine group cell calculation code for fast reactor
International Nuclear Information System (INIS)
A cell calculation code SLAROM-UF was developed to improve calculation accuracy of effective cross sections for various fast reactor types. SLAROM-UF has a capability to calculate effective cross sections in ultra fine groups of about 100,000 below 50keV and in fine groups above the energy (maximum 900 groups). Resonance interaction among the fuel, the coolant, and the structure materials can be treated accurately even in a heterogeneous cell structure. Temperature can be set up freely in a cell by the ultra fine group calculation. Improvement in nuclear characteristics was observed in the analysis of JUPITER critical experiment, as 0.1% for criticality, 4% for sodium void reactivity, several % for radial reaction rate distribution, when SLAROM-UF was used instead of the typical cell calculation code. The effect of the ultra fine group calculation is remarkable in the non-leakage term of sodium void reactivity, and that of the fine group ...
Energy Technology Data Exchange (ETDEWEB)
Significant ion irradiation during film growth is required for the formation of cubic boron nitride (cBN) films. Meanwhile, a huge level of intrinsic stress possibly induced by the ion bombardment has been frequently reported to result in cracking and/or lack of adhesion of deposited cBN films. The present work has been performed to investigate the interfacial and/or the buffer layer structures with better matching to the cBN film by relaxation of the film stress using ion-beam-assisted deposition (IBAD). Boron nitride films have been synthesized on Si(100) wafer and tungsten carbide (WC) substrates by depositing boron vapor under simultaneous bombardment with nitrogen ions and nitrogen-argon mixture ions in the energy range of 0.5-10 keV. Cubic BN films with enhanced tribological properties have been explored by inserting a BN layer with various B/N compositions as a controlled buffer at the interface. Significant relaxation of the film stress has been observed ...
1999-09-01
Modification of the passivity of iron based alloys through ion implantation
International Nuclear Information System (INIS)
As an unconventional surface alloying process, ion implantation has been utilized to improve the active-passive behavior and the pitting resistance of martensitic M50 engineering alloy. In a field simulation study, Cr-implantation only at 150 kev to a fluence of 2 x 10"1"7 ions/cm"2 prevented pitting. The best pitting resistance of the steel was obtained with multiple implantations of Cr and Mo. The intermixing effect of high fluence P-implantation into 304 stainless produced an amorphous surface alloy. The removal of the grain boundaries and the uniformity of the resulting structure had a great influence on corrosion properties. REED analysis indicated that the anodic passive films formed on P-implanted 304 stainless steel at 250 mV (SCE) in 0.5M H_2SO_4 was amorphous. Phosphorus and boron were implanted into 316 stainless steel to study the passivity of 316 stainless. Electrochemical experiments were carried out to evaluate the effects of ...
1764-01-01
Importance of neutron data in fission reactor applications
International Nuclear Information System (INIS)
The neutron data required to completely analyze fission reactors includes many isotopes and covers a broad energy range. In both fast and thermal reactors, the neutron inventory is a fine balance determined by the fission properties of "2"3"5U, "2"3"9Pu and "2"3"8U and by the capture cross sections of "2"3"8U, fuel materials, structural materials and coolant materials. In fast reactors, the spectrum of neutrons ranges from 1 keV to 3 MeV and is influenced by the elastic and inelastic scattering properties of "2"3"8U and the structural and coolant materials. For neutron shielding applications, the important neutron data include the total cross sections of structural and coolant materials in the MeV range. The impact of these basic nuclear data in fission reactor applications is most suitably described by sensitivity analysis. For example, sensitivity coefficients computed for a typical large plutonium fueled fast reactor indicate that a percent ...
1976-07-06
International Nuclear Information System (INIS)
The concentration of trace elements in brain sections was measured by synchrotron radiation X-ray fluorescence. The relative concentration was calculated by means of the normalization of Compton scattering intensity approximately 22 keV, after the normalization for collecting time of X-ray spectrum and the counting of the ion chamber, and subtracting the contribution of the polycarbonate film for supporting sample. Furthermore, the statistical evaluation of the element distribution in various regions of the brain sections of the 20-day-old rats was tested. For investigating the distribution of elements in the brain of iodine deficient rats, Wistar rats were fed with iodine deficient diet and deionized water (ID group). The rats were fed the same iodine deficient diet, but drank KIO_3 solution as control (CT group). The results showed that the contents of calcium (Ca) in thalamus (TH) and copper (Cu) and iron (Fe) in cerebral cortex (CX) of ID rats were ...
2004-02-27
ANALYSIS OF ACCELERATOR BASED NEUTRON SPECTRA FOR BNCT USING PROTON RECOIL SPECTROSCOPY
Energy Technology Data Exchange (ETDEWEB)
Boron Neutron Capture Therapy (BNCT) is a promising binary treatment modality for high-grade primary brain tumors (glioblastoma multiforme, GM) and other cancers. BNCT employs a boron-10 containing compound that preferentially accumulates in the cancer cells in the brain. Upon neutron capture by {sup 10}B energetic alpha particles and triton released at the absorption site kill the cancer cell. In order to gain penetration depth in the brain Fairchild proposed, for this purpose, the use of energetic epithermal neutrons at about 10 keV. Phase I/II clinical trials of BNCT for GM are underway at the Brookhaven Medical Research Reactor (BMRR) and at the MIT Reactor, using these nuclear reactors as the source for epithermal neutrons. In light of the limitations of new reactor installations, e.g. cost, safety and licensing, and limited capability for modulating the reactor based neutron beam energy spectra alternative neutron sources are being contemplated for wider ...
1998-11-06
A spatial sensitivity analysis technique for neutron and gamma-ray measurements
International Nuclear Information System (INIS)
In the fields of medical imaging, geophysical well logging, and industrial radiography, it is often of interest to characterize the spatially distributed sensitivities of neutron and gamma-ray measurement devices to the physical properties of the materials being examined. For instance, one may wish to know how the count rate in a detector varies in response to small changes in the local density of the irradiated object as a function of position. Experimental determination of such sensitivity functions is often impractical. Consequently, we have developed a general three-dimensional Monte Carlo numerical technique that allows us to directly compute the differential sensitivity of an arbitrary integral response parameter, such as a time- or energy-discriminated count rate, with respect to the spatial distribution of macroscopic cross sections and sources in the irradiated medium. Sensitivities to object density, porosity, etc., can easily be derived from these computed fundamental ...
1992-09-08
ppbar enhancement in B and J/Psi decay
The near-threshold enhancement in the ppbar invariant mass spectrum from the B^+ -> K^+ ppbar decay reported recently by the BaBar Collaboration is studied within the J\\"ulich NNbar model. We illustrate that the invariant mass dependence of the ppbar spectrum close to the threshold can be reproduced by the final state interactions. This explanation is in line with our previous analysis of the ppbar invariant mass spectrum from the J/Psi -> gamma ppbar decay measured by the BES Collaboration. We also comment on a structure found recently in the pi^+ pi^- eta' mass spectrum of the radiative J/Psi decay by the BES Collaboration. In particular we argue that one should be rather cautions in bringing this structure in connection with the enhancement found in the ppbar invariant mass spectrum or with the existence of NNbar bound states.
2006-01-01
British Library Electronic Table of Contents (United Kingdom)
Nano- and microstructured surfaces are known to impact on the binding and differentiation of cells, but the detailed basic understanding of the underlying regulatory mechanisms is still scarce, which impedes the rational design of smart biomaterials. Towards a comprehensive analysis of the interplay between topographical parameters such as feature design and lateral and vertical dimensions we here report on a combinatorial screening approach, BioSurface Structure Array (BSSA) of test squares each with a distinct topography. Using such BSSA libraries of 504 topographically distinct surface structures, we have identified combinations of size, gap and height of structures which enhance mineralization as well as the expression of osteogenic markers of a preosteoblastic murine cell line. This g...
2009-01-01
British Library Electronic Table of Contents (United Kingdom)
Abstract Aims: The aim of this study was to examine whether metabolic syndrome (MS) is associated with periodontitis in a representative sample of Korean adults, who were involved in the Fourth Korea National Health and Nutrition Examination Survey (KNHANES). Materials and Methods: A total of 7178 subjects over the age of 19 years who participated in KNHANES were examined. MS was defined as the definition proposed by the National Cholesterol Education Program Adult Treatment Panel III and the abdominal obesity cut-off line based on Korean Society for the Study of Obesity. The periodontal status was assessed by the Community Periodontal Index. Multivariate logistic regression analysis was carried out adjusting for the sociodemographics, oral health behaviours and status, and health behaviou...
2011-01-01
Surface Characterization of Stainless Steel Part by Eddy Current
Energy Technology Data Exchange (ETDEWEB)
The Pacific Northwest National Laboratory (PNNL) has nearly a 40 year history of research and development in the field of nondestructive evaluation (NDE). One area of NDE expertise at PNNL is electromagnetic testing which includes a field of eddy current testing (ET). One benefit is that ET can typically be performed at high speeds, and as a result has found many applications in process monitoring and poduction lines. ET has been used in the nuclear, aerospace, and automotive industries for many years. Et technology lends itself well to the detection of near-surface or surface breaking defects such as surface scratches. This paper provides an overview of theory regarding the usage of ET, selected application studies performed by PNNL, a safety analysis, and a wrtie up pertaining to the operations of ET to detect surface scratches.
2003-10-01
Energy Technology Data Exchange (ETDEWEB)
Buses, operating within a Florence (Italy) municipal transportation system, and equipped with Otto cycle engines, were selected for retrofitting taking into account the suitability of each vehicle`s specific routing and service requirements. Cost benefit analyses indicated that it wouldn`t be economically feasible to retrofit buses equipped with diesel engines. A computerized refuelling system was set up at the fleet`s central service station which was hooked up to the natural gas utility`s supply line. This paper tables the cost benefit analysis data comparing gasoline and methane operation and reflecting the cost savings which are expected to be accrued through this methanization program over a span of 14 years.
1992-12-31
British Library Electronic Table of Contents (United Kingdom)
The paper deals with the reliability-based design optimization (RBDO) of a riser support installed on a floating production storage and offloading (FPSO) unit under operation, extreme, damaged, and one line failure cases and installation loading conditions. The optimization problem is formulated such that probabilistic thickness variables described with random characteristics are determined by minimizing the weight of the riser support structure subjected to stress constraints for the given target reliability. The initial design model is generated based on actual FPSO riser support specifications. The finite element analysis is conducted using NASTRAN, and the probabilistic optimal solutions are obtained via the moving least squares method in the context of RBDO using a response surface me...
2011-01-01
International Nuclear Information System (INIS)
Protective goals set the line of orientation of tasks and activities in the field of accident prevention. They have to be based on safety-science methods in order to develop from the conceptual idea to the practically feasible solution, while using the scientific methods to take into account the facts and the capabilities of a situation and, proceeding from them, finding an efficient and rational, optimal pragmatic approach by way of various strategies or tactics. In this process, the activities of defining, informing, thinking and developing need the proper terminology. Safety is absence of danger, protection is limitation of danger and prevention of damage. So it is protection what is needed with danger being given, and risks have to be minimized. Riskology is a novel method of safety science, combining risk analysis and risk control into a systematic concept which is practice-oriented. Applying this to the field of nuclear engineering, the ...
Production and characterization of ultrafine WC powders
International Nuclear Information System (INIS)
The conventional Calzination-Reduction-Carburization (CRC) process offers the potential to manufacture commercial WC powders with median SEM grain sizes below 0.5 pm (ultra fine grades). Strict process control and a high degree of automation have led to increased powder uniformity and high lot-to-lot reliability. The high potential and flexibility of the CRC process is shown by the development of tailor made WC powders with regard to subsequent alloy manufacturing. R and D powders have successfully been processed in full-scale units exhibiting SEM grain sizes of 0.15 - 0.20 pm. This paper discusses the powder characteristics of various ultra fine WC powder grades, stemming from the conventional CRC process. Analytical characterization include also field-emission SEM, bright field TEM, EDX analysis and XRD-line broadening. (author)
2001-05-01
Pentobarbital anesthesia alters neural responses in the precedence effect
British Library Electronic Table of Contents (United Kingdom)
The precedence effect (PE) is thought to be beneficial for proper localization and perception of sounds. The majority of recent physiological studies focus on the neural discharges correlated with PE in the inferior colliculus (IC). Pentobarbital anesthesia is widely used in physiological studies. However, little is known of the effect of pentobarbital on the discharge of neurons in PE. Neuronal responses in the IC from 23 male SD rats were recorded by standard extracellular recording techniques following presentation of 4ms white noise bursts, presented from either or both of two loud speakers, at different interstimulus delays (ISDs). The neural responses were recorded for off-line analysis before or after intraperitoneal administration of pentobarbital at a loading or maintenance dose. ...
2011-01-01
New technology for purging the steam generators of nuclear power plants
British Library Electronic Table of Contents (United Kingdom)
A technology for removal of undissolved impurities from a horizontal steam generator using purge water is developed on the basis of a theoretical analysis. A purge with a maximal flow rate is drawn off from the zone with the highest accumulation of sludge in the lower part of the steam generator after the main circulation pump of the corresponding loop is shut off and the temperatures of the heat transfer medium at the inlet and outlet of the steam generator have equilibrated. An improved purge configuration is used for this technology; it employs shutoff and regulator valves, periodic purge lines separated by a cutoff fixture, and a D y 100 drain union as a connector for the periodic purge. Field tests show that the efficiency of this technology for sludge removal by purge water is severa...
2011-01-01
Low-cycle fatigue behaviour and microstructure of copper and alpha-brass under biaxial load paths
Energy Technology Data Exchange (ETDEWEB)
The low-cycle fatigue behaviour of copper and a-brass CuZn30 was investigated in uniaxial and biaxial tests. Planar biaxial fatigue tests were carried out using cruciform samples with proportional stain paths with and without phase shift between the two axes. Microcharacterisation was performed by electron microscopy as well as by high-resolution X-ray line profile analysis. The biaxial cyclic stress-strain curves show good agreement with the uniaxial ones using the von Mises equivalent strain hypothesis. The dislocation densities and microhardness values of the biaxial case, however, show significantly lower values compared to the uniaxial case at equivalent von Mises stresses.
2010-07-01
British Library Electronic Table of Contents (United Kingdom)
Low pressure turbine blades (LPT) made by investment casting from intermetallic titanium aluminide alloys for aero-engine applications in lengths between 200 and 400 mm require very demanding and sophisticated process for their manufacturing. Middle line shrinkage porosity along the airfoil and dimensional tolerances by near-net-shape casting are especially sensitive issues concerning Quality assurance. Nevertheless the urgency to manufacture safer environmental-friendly high performance aero-engines requires the introduction of new high performance components like LPT blades made of TiAl, which are about 50% lighter than their nickel-based counterparts. The present work is based on process engineering taking into account different melting and casting technologies in order to develop a dep...
2011-01-01
In vitro and in vivo evaluation of [{sup 123}I]-VEGF{sub 165} as a potential tumor marker
Energy Technology Data Exchange (ETDEWEB)
One of the research challenges in oncology is to develop new biochemical methods for noninvasive tumor therapy evaluation to determine whether the chemotherapeutics is effective. Vascular endothelial growth factor (VEGF) was labeled with radioiodine and evaluated in vitro as well as in vivo, using A2058, a melanoma cell line overexpressing VEGFR-1 and -2. Saturation binding analysis with [{sup 125}I]-VEGF resulted in a K {sub d} of 0.1 nM. Internalization assays indicate the preserved ligand induced internalization and metabolization of the tracer. Biodistribution studies with [{sup 123}I]-VEGF in wild type and A2058 tumor-bearing athymic mice showed low background activity and a tumor to reference tissue ratio of maximum 6.12. These results suggest that [{sup 123}I]-VEGF is a potentially suitable tracer for tumor therapy evaluation.
2005-07-01
Importance of level structure in nuclear reaction cross-section calculations. Revision 1
It is shown that level-density expressions cannot adequately represent or substitute for level structure information when making calculations of the Hauser-Feshbach type for cross sections or isomer-ratios for nuclei in the first few MeV above their ground state. It is stated that such discrete level information should include both experimentally confirmed and theoretically predicted levels. The utility of discrete level information to optimize level density calculations, to compute isomer ratios, in deriving dipole strength functions, and in the analysis of primary gamma ray spectra is emphasized, especially for nuclei far from the line of stability. 29 refs., 12 figs., 6 tabs. (DWL)
1985-11-07
British Library Electronic Table of Contents (United Kingdom)
DNA methylation is considered as a potential cause of aberrations in regulation of gene expression during carcinogenesis. Therefore, changes in DNA methylation patterns may be targets for chemoprevention. In the present study, we investigated effects of all-trans retinoic acid (ATRA), vitamin D3, and resveratrol alone and in combination with adenosine analogues: 2-chloro-2'-deoxyadenosine (2CdA) and 9-beta-d-arabinosyl-2-fluoroadenine (F-ara-A), on methylation and expression of retinoic acid receptor beta 2 (RARbeta2) in MCF-7 and MDA-MB-231 breast cancer cell lines. Alterations in methylation and expression levels after treatment of cells with the tested compounds were evaluated by methylation-sensitive restriction analysis (MSRA) and real-time PCR, respectively. RARbeta2 promoter in the ...
2010-01-01
High-resolution spectroscopy of Er{sup 3+} ions in 6H SiC
Energy Technology Data Exchange (ETDEWEB)
In this work, we present results of a systematic study of optical properties of Er{sup 3+} ions in 6H SiC. The role of N-donors played in activation of photoluminescence (PL) of erbium at 1.5 {mu}m was investigated. We have confirmed that N-donors are necessary for activation of the Er PL on one hand, whereas on the other we present evidence that N-donors compete for excitation with Er centres. The high-resolution measurements of the Er{sup 3+} PL were performed aiming at determination of crystal field split levels of the {sup 4}I{sub 15/2} ground and {sup 4}I{sub 13/2} first excited multiplet of Er{sup 3+} ions. Careful analysis of temperature evolution of individual PL lines allowed proposing energy level schemes for the ground and first excited states.
2003-12-15
High-resolution spectroscopy of Er"3"+ ions in 6H SiC
International Nuclear Information System (INIS)
In this work, we present results of a systematic study of optical properties of Er"3"+ ions in 6H SiC. The role of N-donors played in activation of photoluminescence (PL) of erbium at 1.5 #mu#m was investigated. We have confirmed that N-donors are necessary for activation of the Er PL on one hand, whereas on the other we present evidence that N-donors compete for excitation with Er centres. The high-resolution measurements of the Er"3"+ PL were performed aiming at determination of crystal field split levels of the "4I_1_5_/_2 ground and "4I_1_3_/_2 first excited multiplet of Er"3"+ ions. Careful analysis of temperature evolution of individual PL lines allowed proposing energy level schemes for the ground and first excited states.
2003-12-15
Feasibility study of the iterative x-ray phase retrieval algorithm
International Nuclear Information System (INIS)
An iterative phase retrieval algorithm was previously investigated for in-line x-ray phase imaging. Through detailed theoretical analysis and computer simulations, we now discuss the limitations, robustness, and efficiency of the algorithm. The iterative algorithm was proved robust against imaging noise but sensitive to the variations of several system parameters. It is also efficient in terms of calculation time. It was shown that the algorithm can be applied to phase retrieval based on one phase-contrast image and one attenuation image, or two phase-contrast images; in both cases, the two images can be obtained either by one detector in two exposures, or by two detectors in only one exposure as in the dual-detector scheme.
2009-01-01
British Library Electronic Table of Contents (United Kingdom)
I. S. Kirbis, P. Maxwell, M. S. Flear, K. Miller and M. Ibrahim External quality control for immunocytochemistry on cytology samples: a review of UK NEQAS ICC (cytology module) results Objective:- To date, external quality control for immunocytochemistry on cytology samples is provided only by the United Kingdom national external quality assessment service for immunocytochemistry and in situ hybridisation (UK NEQAS ICC & ISH). For the purpose of this study a retrospective analysis of a comprehensive collection of quality-related data regarding immunocytochemistry on cytology samples collected through this service was analysed. Methods:- The quality of immunocytochemical reactions, using on-line collected data, was analysed for the last 23 UK NEQAS ICC cytology module external quality asses...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
'The overall objective of the basic research grant is to characterize the potential of common hydrocarbon contaminants in ecosystems to act as endocrine disruptors. The three major lines of research include (1) a biotechnology based screening system to identify potential hormone mimics and antagonists; (2) an animal screening system to identify biomarkers of endocrine effects. and (3) a literature review to identify compounds at a variety of DOE sites that need to be examined for endocrine disrupting effects. By relating results obtained from this research project to contamination problems at various DOE sites. CBR will provide data and information on endocrine disrupting contaminants to DOE for consideration in risk analyses for determining clean-up levels and priorities needed at the sites.'
1997-01-01
British Library Electronic Table of Contents (United Kingdom)
ABSTRACT This research examined whether the Internet improves life satisfaction. The study surveyed 195 college students, and a structural model was built to explain effects of the Internet on school life satisfaction using a confirmatory factor analysis (CFA). In line with social cognitive theory and literature on social effects of the Internet, current data supported the hypotheses that Internet use, perceived online social support, and online social self-efficacy had direct positive impacts on school life satisfaction. Offline extroversion, online extroversion, online social self-efficacy, and online social outcome expectations influenced school life satisfaction indirectly: offline extroversion acted through social online self-efficacy and online extroversion; online social self-effica...
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
A three-component seismic line acquired over the Zamora gas field, northern Sacramento Valley, California, displays conventional (P-P) and converted-wave (P-SV) seismic anomalies. Well log and seismic modeling results indicate that bright-spot reflection strengths are related to variations in fluid saturation and lithology. The P-SV reflection strengths and interval velocities provide valuable information that complements more conventional strategies such as amplitude with offset and polarity analysis. This integrated strategy can improve risk evaluation and well-site selection in areas where rapid changes in reservoir quality impact resource evaluation.
1989-03-01
Energy Technology Data Exchange (ETDEWEB)
A three-component seismic line acquired over the Zamora gas field, northern Sacramento Valley, California, displays conventional (P-P) and converted-wave (P-SV) seismic anomalies. Well log and seismic modeling results indicate that bright-spot reflection strengths are related to variations in fluid saturation and lithology. The converted-wave reflection strengths and interval velocities provide valuable information that compliments more conventional strategies such as amplitude with offset and polarity analysis. This integrated strategy can improve risk evaluation and well site selection in areas where rapid changes in reservoir quality impact resource evaluation.
1989-04-01
British Library Electronic Table of Contents (United Kingdom)
A red basil cell line (T2b) rich in rosmarinic acid (RA) was selected for the stable production of anthocyanins (ACs) in the dark. Cell suspension cultures were subjected to mechanical stress through increased agitation (switch from 90 to 150rpm) to determine the relationship between AC and RA accumulation. Cell extracts were analyzed by HPLC and LC-MS, and the resulting data were processed with multivariate statistical analysis. MS and MS/MS spectra facilitated the putative annotation of several complex cyanidin-based ACs, which were esterified with coumaric acid and, in some cases, also with malonic acid. It was also possible to identify various RA-related molecules, some caffeic and coumaric acid derivatives and some flavanones. Mechanical stress increased the total AC and RA contents, ...
2011-01-01
Cause analysis and preventives for human error events in Daya Bay NPP
International Nuclear Information System (INIS)
Daya Bay Nuclear Power Plant is put into commercial operation in 1994 Until 1996, there are 368 human error events in operating and maintenance area, occupying 39% of total events. These events occurred mainly in the processes of maintenance, test equipment isolation and system on-line, in particular in refuelling and maintenance. The author analyses root causes for human errorievents, which are mainly operator omission or error procedure deficiency; procedure not followed; lack of training; communication failures; work management inadequacy. The protective measures and treatment principle for human error events are also discussed, and several examples applying them are given. Finally, it is put forward that key to prevent human error event lies in the coordination and management, person in charge of work, and good work habits of staffs.
Basic uranyl perrhenate and its crystallohydrates
Energy Technology Data Exchange (ETDEWEB)
UO/sub 2/(OH)xReO/sub 4/xH/sub 2/O, UO/sub 2/(OH)ReO/sub 4/x0.5H/sub 2/O and UO/sub 2/(OH)ReO/sub 4/ were produced and their physical and chemical properties were studied for the first time. The chemical analysis was carried out and pycnometric density of the initial crystallohydrate and basic uranyl anhydrous perrhelate wos determined. The two-step mechanism of the dehydration of uranyl hydroxoperrhenate monohydrate was revealed. Values of interplane distances were calculated for a number of roentgenogram lines of the basic uranyl perrhenate and its crystallohydrates. IR spectra of all revealed compounds in the region of 4000-250 cm/sup -1/ were studied.
1982-11-01
A mobile gamma scanning system for detecting radiation anomalies
Energy Technology Data Exchange (ETDEWEB)
A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A /sup 226/Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.
1983-09-01
A mobile gamma scanning system for detecting radiation anomalies
International Nuclear Information System (INIS)
A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A "2"2"6Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.
Twenty-two landrace-derived inbred lines from the Spanish Barley Core Collection (SBCC) were found to display high levels of resistance to a panel of 27 isolates of the fungus Blumeria graminis that exhibit a wide variety of virulences. Among these lines, SBCC145 showed high overall resistance and a distinctive spectrum of resistance compared with the other lines. Against this background, the main goal of the present work was to investigate the genetic basis underlying such resistance using a doubled haploid population derived from a cross between SBCC145 and the elite spring cultivar Beatrix. The population was genotyped with the 1,536-SNP Illumina GoldenGate Oligonucleotide Pool Assay (Barley OPA-1 or BOPA1 for short), whereas phenotypic analysis was performed using two B. graminis isolates. A major quantitative trait locus (QTL) for resistance to both isolates was identified on the long arm of ...
2011-07-08
International Nuclear Information System (INIS)
The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 ("1"6N) and Oxygen-19 ("1"90) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of "1"9O and "1"6N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high background even though sensitivity is appreciably good. For detector position out side the RB containment, the travel time for the feed water becomes ...
2005-11-23
The origin and physical mechanism of the ensemble Baldwin effect
We have conducted a systematic investigation of the origin and underlying physics of the line--line and line--continuum correlations of AGNs, particularly the Baldwin effect. Based on the homogeneous sample of Seyfert 1s and QSOs in the SDSS DR4, we find the origin of all the emission-line regularities is Eddington ratio (L/Ledd). The essential physics is that L/Ledd regulates the distributions of the properties (particularly column density) of the clouds bound in the line-emitting region.
2009-01-01
Principles of ground relaying for high voltage and extra high voltage transmission lines
Energy Technology Data Exchange (ETDEWEB)
This paper is a tutorial discussion of the basic principles of ground relaying for high voltage and extra high voltage transmission lines. Three different HV configurations are considered: Long lines, lines with a weak mid-point station, and mutually-coupled lines. Application criteria for EHV circuits are also discussed, and specific setting calculations are included where appropriate.
1983-02-01
Reliability analysis of FPSO mooring systems and the interaction with risers
Energy Technology Data Exchange (ETDEWEB)
Turret moored Floating Production Storage and Offloading (FPSO) systems are considered suitable for a wide range of environmental conditions but experience of designing moorings for these units in harsh environments is limited. Furthermore, each floating production system has its own requirements as to the way the riser system is operated because of its dependence on both reservoir and site specific conditions. The current mooring codes do not have a consistent set of requirements; for example, the intact mooring system safety factors range from 1.5 to 2.3. Such vastly differing requirements result in wide variability in the intrinsic safety, reliability and cost. This paper describes a reliability analysis carried out for the first North Atlantic FPSO (Foinaven), to address the acceptance criteria for moorings by returning to the fundamentals. Although the analysis deals with FPSO`s, the approach is applicable to any catenary moored unit. One ...
1996-12-31
Traditional Fusion reaction: D + T n (14.07 MeV) + 4He (3.52 MeV ...
as for direct energy conversion in specialized direct electrical energy conversion plants. Figure 1. An energetic (~163KeV) proton and a 11boron nucleus fuse ...
International Nuclear Information System (INIS)
The decay of "1"0"1Mo to levels in "1"0"1Tc has been studied using the three-parameter (#gamma#-#gamma#-t) coincidence system of HpGe-HpGe detectors. According to the coincidence data, the decay scheme was modified. The positions of 221.80, 318.00, 377.90, 452.50, 515.42, 1011.05 and 1759.72 keV transitions have been arranged again, the transition positions of 104.70, 105.95 and 774.15 keV gamma-rays have been assigned for the first time, the positions of 169.00, 590.91, 980.52 and 1431.68 keV transitions have been reconfirmed, the 1508.01 keV gamma-ray was observed simultaneously for the first time and its transition position has been assigned. The #beta#-intensities and the values of log ft of most levels were calculated. (author)
2000-09-01
Studies on energy level schemes of some nuclei by Gamma-ray spectroscopy
International Nuclear Information System (INIS)
several authors tried to drive codes to construct nuclear level scheme of nuclei using a set of measured gamma -ray transitions and known energy levels, Ritz combination principle proved to be useful in constructing a more complete decay scheme. In this thesis the energy level schemes of some nuclei have been investigated by the measurements of the gamma - ray energies and use of Ritz combination code. The nuclei under investigation are "110m Ag (253 d)"110 Cd and "166m Ho (1200 yr) "166 E r. On the basis of the suggested level at 2249.02 keV by the Ritz code new positions of the two gamma-ray transitions at 677.5 and 706.6 KeV are found in decay scheme of "110m Ag. Also by this code, new position for the 994.84 KeV gamma-ray transition were established to depopulate the level at 1075.2 KeV.
1984-01-01
Mechanism for the reduction of interstitial supersaturations in MeV-implanted silicon
Energy Technology Data Exchange (ETDEWEB)
We demonstrate that the excess vacancies induced by a 1 MeV Si implant reduce the excess interstitials generated by a 40 keV Si implant during thermal annealing when these two implants are superimposed in silicon. It is shown that this previously observed reduction is dominated by vacancy annihilation and not by gettering to deeper interstitial-type extended defects. Interstitial supersaturations were measured using B doping superlattices (DSL) grown on a silicon-on-insulator (SOI) substrate. Implanting MeV and keV Si ions into the B DSL/SOI structure eliminated the B transient enhanced diffusion normally associated with the keV implant. The buried SiO{sub 2} layer in the SOI substrate isolates the deep interstitials-type extended defects of the MeV implant, thereby eliminating the possibility that these defects getter the interstitial excess induced by the keV Si implant. {copyright} {ital 1999 ...
1999-03-01
Mechanism for the reduction of interstitial supersaturations in MeV-implanted silicon
International Nuclear Information System (INIS)
We demonstrate that the excess vacancies induced by a 1 MeV Si implant reduce the excess interstitials generated by a 40 keV Si implant during thermal annealing when these two implants are superimposed in silicon. It is shown that this previously observed reduction is dominated by vacancy annihilation and not by gettering to deeper interstitial-type extended defects. Interstitial supersaturations were measured using B doping superlattices (DSL) grown on a silicon-on-insulator (SOI) substrate. Implanting MeV and keV Si ions into the B DSL/SOI structure eliminated the B transient enhanced diffusion normally associated with the keV implant. The buried SiO_2 layer in the SOI substrate isolates the deep interstitials-type extended defects of the MeV implant, thereby eliminating the possibility that these defects getter the interstitial excess induced by the keV Si implant. copyright 1999 American Institute ...
1999-03-01
Measurement of the 183 keV Resonance in 17O(p,alpha)14N using a Novel Technique
Energy Technology Data Exchange (ETDEWEB)
We have developed a novel technique for measurements of low energy (p,alpha) reactions using heavy ion beams and a differentially-pumped windowless gas target. We applied this new approach to study the 183 keV resonance in the 17O(p,alpha)14}N reaction. We report a resonance energy (center-of-mass) of 183.5{+0.1}{-0.4} keV, a resonance strength of 1.70 +/- 0.15 meV, and set an upper limit (95\\% confidence) on the total width of the state of < 0.1 keV. This resonance is important for the 17O(p,alpha)14}N reaction rate, and we find that 18F production is significantly decreased in low mass ONeMg novae but less affected in more energetic novae. We also report the first determination of the stopping power for oxygen ions in hydrogen gas near the peak of the Bragg curve (E=193 keV/u) to be (63+/-1)e-15 eV-cm2.
2007-06-01
Ion beam pulsing for time of flight (TOF) experiments
Energy Technology Data Exchange (ETDEWEB)
The essential mechanical and electronic parts of a beam pulsing system are described, which reaches an energy resolution of ..delta..E/E=0.1%-0.4% in the energy range from 100 eV and 10 keV.
1985-01-01
Experimental research on passive #gamma# scanning system at hot-cell for hull monitoring
International Nuclear Information System (INIS)
A simulated hull monitoring system based on passive #gamma# ray scanning was set-up in K-01 hot-cell, which consists of a simulated hull basket, a collimator system, a 150 cm"3 HPGe detector and an ORTEC-919 multichannel buffer-computer system. Six different kinds of experimental set-up were established to simulate the variations of #gamma# ray source term distribution (partly concentration) and the variations of matrix density (+46.1%). The experimental results show that the biases of peak area is better than -25.3% for "1"3"7Cs 662 keV #gamma# rays and -18.6% for "1"4"4Ce-"1"4"4Pr 2186 keV #gamma# rays. The hardness of pulse height spectrum is demonstrated to show that the peak area ratio of 2186 keV to 662 keV varies from 380 to 72 when the thickness of lead filter varies form 5 mm to 30 mm. Also studied are the design parameters of collimator system.
Electron Flux - 8.0 keV - ISWA wiki - ISWA - NASA
Nov 14, 2009 ... Ring Current electrons from the Fok Ring Current Model are computed using plasma and magnetic field values from the SWMF magnetosphere ...
Electron Flux - 4.7 keV - ISWA wiki - NASA
Nov 14, 2009 ... Ring Current electrons from the Fok Ring Current Model are computed using plasma and magnetic field values from the SWMF magnetosphere ...
Electron Flux - 179 keV - ISWA wiki - ISWA - NASA
Nov 14, 2009 ... Ring Current electrons from the Fok Ring Current Model are computed using plasma and magnetic field values from the SWMF magnetosphere ...
Annealing behavior of radiation damages in metal-silicides
International Nuclear Information System (INIS)
The annealing behavior of the radiation damage in epitaxial Pd_2Si and NiSi_2 films on Si, due to the implantation of 100 keV Ar ions, is investigated by using the channeling technique with "4He ions. (U.K.).
International Nuclear Information System (INIS)
Total M X-ray cross sections for 12 elements in atomic range 70#<=#Z#<=#92 were measured at 5.96 keV Mn K X-ray photon energy. The average M shell fluorescence yields (anti #omega#_M) of these elements have also been observed using the presently measured cross section values and the theoretical M shell photoionisation cross section values. (orig.).
Investigation of the "1"0"1Mo level and gamma-decay scheme by thermal neutron capture in "1"0"0Mo
International Nuclear Information System (INIS)
The #gamma#-radiation following thermal neutron capture in "1"0"0Mo has been studied by singles and coincidence measurements. A "1"0"1Mo level scheme has been deduced and is compared with the results of previous (d,p), (n,#gamma#) and "1"0"1Nb decay studies. The existence of the first excited state at 13.51 keV has been confirmed. The present data yield a neutron binding energy of 5398.4 KeV. (Auth.).
1975-03-01
Inelastic scattering of electrons by close-lying levels of isomeric nuclei
Energy Technology Data Exchange (ETDEWEB)
The process of inelastic scattering of hot plasma electrons with energies upto 3 keV by a pair of close-lying nuclear levels (..delta../ital E/less than or equal to2keV), one of whichis isomeric, is discussed. The transition cross sections in the nuclei/sup 242/Am, /sup 171/Lu, and /sup 73/Se are calculated. Estimates of the numberof isomeric nuclei de-excited as a result of electron-stimulated processes in aplasma with parameters characteristic of present-day experiments in controlledthermonuclear fusion are given.
1988-11-01
Energy Technology Data Exchange (ETDEWEB)
Neutral atom beams with energies above 200 keV may be required for various purposes in magnetic fusion devices following TFTR, JET and MFTF-B. These beams can be produced much more efficiently by electron detachment from negative ion beams than by electron capture by positive ions. We have investigated the efficiency with which such neutral atoms can be produced by electron detachment in partially ionized hydrogen plasma neutralizers.
1980-09-01
Energy Technology Data Exchange (ETDEWEB)
As an interim report on the study on vibration of transmission lines when gust is blowing, this paper introduces events of confused and other contacts between transmission lines, photographing of transmission line vibration, physical measurement on transmission line response, and development of simulation software. Events of confused contacts of high-voltage transmission lines with overhead ground wires have the following common conditions: gust blows nearly perpendicularly to the line direction; no obstacles exist in upwind directions; the wind blows upward or downward against high-voltage transmission lines; and size of the high-voltage transmission lines is 25 mm{sup 2}. According to photographs of transmission line vibration, it appears that gust caused a high-voltage transmission ...
1996-03-25
Electric and magnetic field exposures for people living near a 735-kilovolt power line.
UK PubMed Central (United Kingdom)
The purpose of this study was to assess the effect of a 735-kV transmission line on the electric and magnetic field exposures of people living at the edge of the line's right of way. Exposure of 18...Full Text Available
1995-09-01
International Nuclear Information System (INIS)
Decaborane (B_1_0H_1_4) cluster ions were implanted into n-Si(100) substrates to fabricate shallow p"+/n junctions. Implant energies of 2 keV, 5 keV, and 20 keV, equivalent to implant energies of the monomer boron ion of 174 eV, 435 eV, and 1.74 keV, respectively, were used at dosages of 1 X 10"1"2 /cm"2 and 1 X 10"1"3 /cm"2. The implanted samples were then subjected to activation annealing at 800 .deg. C, 900 .deg. C, and 1000 .deg. C for 10 s. By using secondary ion mass spectrometry (SIMS) depth profiles, we determined that the depth of the shallow junction (D_s) at a dosage of 1 X 10"1"3 /cm"2 was in the range 12 nm - 45 nm after annealing at 1000 .deg. C. D_s and transient enhanced diffusion (TED) were greatly reduced at implant energies lower than 5 keV, but thermal diffusion (TD) smoothly decreased. In particular, TED was suppressed in the p"+/n junction implanted at 2 ...
2004-06-01
Energy Technology Data Exchange (ETDEWEB)
A method, which estimates the lightning performance of high voltage transmission lines based on the Monte-Carlo simulation technique, is described in this paper. The average number of faults which occur in a transmission line, dividing them in single-phase and three-phase faults, as well as the average grounding resistances of the transmission lines are calculated. The method is applied, on several operating Greek transmission lines, showing good correlation between predicted and field observation results. The proposed method can be used as a useful tool in the design of electric power systems, aiding in the right insulation dimensioning of a transmission line.(author)
2003-02-01
An accurate fault location on mutually coupled transmission lines using synchronized sampling
Energy Technology Data Exchange (ETDEWEB)
The mutual inductance between parallel transmission lines influences the locating of the transmission line faults. A fault location algorithm for parallel lines developed in this paper takes into account the magnetic coupling between parallel lines. The paper presents a detailed description of the developed algorithm and test results performed on a simplified real transmission line. The obtained error is less than 0.5 percent in most cases. Also, the developed algorithm is not sensitive to typical fault parameters, such as: resistance, type, location, and incidence angle. 7 refs, 4 figs, 12 tabs
1995-12-31
Tribological behavior of duplex coating improved by ion implantation
Energy Technology Data Exchange (ETDEWEB)
In the present paper the tribological behavior of the coatings are discussed. Duplex coatings were applied on cold working steel 100Cr6. Samples were plasma nitrided at different thickness of plasma surface layers. TiN was deposited with a classic BALZERS PVD equipment and subsequent ion implantation. Ion implantation was provided with N{sup 5+} ions. The other samples were produced with IBAD technology in DANFYSIK chamber. Wear resistance and exchanges of friction coefficient were measured with on-line test using special designed tribology equipment. Following the tests, the wear zone morphology and characteristics of surface layer structure as well as important properties were investigated by scanning electron microscopy (SEM) and X-ray diffraction analysis (XRD). Scratch adhesion testing was performed using commercially available equipment. Energy dispersive X-ray analysis (EDAX) of the wear-scars on pins provided ...
2004-07-01
Trace Elements in Human Myocardial Infarction Determined by Neutron Activation Analysis
International Nuclear Information System (INIS)
By means of neutron activation analysis, injured and adjacent uninjured human heart tissue from 12 autopsy cases with myocardial infarction are investigated with respect to the concentration of 23 trace elements. The bulk elements K, Na and P are also determined. A recently developed ion-exchange technique, combined with subsequent y-spectrometry, is used. The following trace elements are determined: Ag, As, Au, Ba, Br, Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Hg, La, Mo, Rb, Sb, Sc, Se, Sm, Zn and W. In the injured tissue compared to the uninjured, calculation on a wet weight basis showed a decrease in Co, Cs, K, Mo, P, Rb and Zn, and an increase in Br, Ca, Ce, La, Na, Sb and Sm. The differences in Ca, La, Mo, P and Zn are dependent on the age of the myocardial infarction, and the regression lines for these elements are given. The concentration of the trace elements in uninjured tissue from infarcted hearts is compared to the concentration of these ...
1965-01-01
Sampling and chemical analysis of smoke gas components from the SP Industry Calorimeter
Energy Technology Data Exchange (ETDEWEB)
This report describes the sampling and chemical analyses of smoke gas components for combustion performed in the SP Industry Calorimeter, where continuous measurements of oxygen, carbon dioxide and carbon monoxide are an integrated part of the Calorimeter system. On-line measurements of nitrogen oxides and total amounts of unburnt hydrocarbons were performed. Hydrogen cyanide, hydrogen chloride and ammonia in the smoke were sampled and absorbed in impinger bottles and subsequently analyzed using wet chemical techniques. An adsorbent sampling system was designed to allow the identification and quantitative analysis of individual organic compounds in the smoke. Gas chromatography was utilized with a mass spectrometric detector for the identification and a FID for quantification of the total amounts as well as individual components. A procedure for cleaning the smoke gas duct in between the combustion experiments was designed and found to be ...
1995-12-31
British Library Electronic Table of Contents (United Kingdom)
Emerging evidence suggests that E3 ligases play critical roles in diverse biological processes, including innate immune responses in plants. However, the mechanism of the E3 ligase involvement in plant innate immunity is unclear. We report that a rice gene, OsBBI1, encoding a RING finger protein with E3 ligase activity, mediates broad-spectrum disease resistance. The expression of OsBBI1 was induced by rice blast fungus Magnaporthe oryzae, as well as chemical inducers, benzothiadiazole and salicylic acid. Biochemical analysis revealed that OsBBI1 protein possesses E3 ubiquitin ligase activity in vitro. Genetic analysis revealed that the loss of OsBBI1 function in a Tos17-insertion line increased susceptibility, while the overexpression of OsBBI1 in transgenic plants conferred enhanced resi...
2011-01-01
Resent development by the use of neutron induced nuclear reaction
International Nuclear Information System (INIS)
When the history of neutrons is considered, three large discoveries are recalled, that is, the discovery of neutrons by Chadwick in 1932, the discovery of the nuclear fission of uranium by Hahn and Strassmann in 1938, and the continuation of chain reaction in nuclear fission by Fermi and others in 1942. In neutron capture reaction, the reaction cross section can become very large. The fields of research, to which neutrons have contributed most as the experimental probe, are neutron activation analysis and neutron diffraction. The development of the prompt gamma ray analyzer at the JRR-3M in Japan Atomic Energy Research Institute is reported. This method eliminates the various defects in ordinary neutron activation analysis. By installing the cold neutron source with hydrogen cooling in the JRR-3M, the new field of research was opened. As the combination of a lead-moderated spectrometer and an electron beam type accelerator, the Kyoto University ...
1992-01-01
Reliability analysis for stiff versus flexible piping
Energy Technology Data Exchange (ETDEWEB)
The overall objective of this research project is to develop a technical basis for flexible piping designs which will improve piping reliability and minimize the use of pipe supports, snubbers, and pipe whip restraints. The current study was conducted to establish the necessary groundwork based on the piping reliability analysis. A confirmatory piping reliability assessment indicated that removing rigid supports and snubbers tends to either improve or affect very little the piping reliability. We then investigated a couple of changes to be implemented in Regulatory Guide (RG) 1.61 and RG 1.122 aimed at more flexible piping design. We concluded that these changes substantially reduce calculated piping responses and allows piping redesigns with significant reduction in number of supports and snubbers without violating ASME code requirements. Furthermore, the more flexible piping redesigns are capable of exhibiting reliability levels equal to or higher than the ...
1985-11-01
Record of principal work activities/deliverables
International Nuclear Information System (INIS)
Over the five year period of performance, thirteen task assignments were issued by the DOE to ARINC Research. During the two year base period seven tasks were assigned. Two task assignments were issued for each of the three consecutive one year option periods. Associated with all task assignments were multiple subtasks, some of which required significant effort. These subtasks are appropriately cited in this report under their respective task assignments as principal work activities or deliverables. The technical and management support provided to the DOE under this contract focused on two general areas: (1) appraisal activities and (2) non-appraisal activities. Support to appraisals included planning, document review, developing lines-of-inquiry, interviewing, data collection, report writing, and follow-up. Such work was executed both on-site at the DOE facility under review and off-site. Non-appraisal support was varied and included such areas as document review, ...
2003-09-07
Isotopic analysis of lithium by hollow cathode excitation
Energy Technology Data Exchange (ETDEWEB)
A method for quick, high-accuracy measurement of lithium isotopes has become necessary in carrying out research on the separation and concentration of lithium isotopes by ion exchange. The present report focuses on the application of a hollow cathode, as excitation source, to emission spectral analysis for lithium isotope measurement. The grating monochromator used incorporates a pressure scanned etalon. With decreased Doppler broadening and pressure broadening, the hollow cathode, used as excitation source, can give narrow spectral lines, permitting good separation among them. To achieve a high accuracy, the emission intensity of the hollow cathode should be maintained as stable as possible relative to time. In particular, the stability of a light source can be affected significantly by the chemical form of the sample. A study is also made here to identify a condition where lithium acetate effluent as-obtained from an ion exchange column can ...
1990-04-01
Hydatidiform mole and fetus with normal karyotype: support of a separate entity.
DEFF Research Database (Denmark)
Repetitive hydatidiform mole was observed in four pregnancies. The pregnancies presented with heavy bleeding and vomiting, but the post-evacuation courses were uncomplicated, with rapid regression of serum hCG levels. Cytogenetic investigations, analyses of restriction fragment length polymorphisms, and flow cytometry in three pregnancies were consistent with diploid, biparental conception as the origin of fetal tissue and molar and nonmolar villi. In one pregnancy, the analyses of cytogenetic markers suggested the coexistence of two different cell lines of dizygotic, biparental origin, whereas DNA analysis was consistent with a single conception. With incomplete genetic information, a hydatidiform mole with coexistent normal fetus is generally considered to result from dizygous twinning comprising an androgenetic complete mole and a normal conception. In the present gestations, the results based on several techniques applied on numerous ...
1991-01-01
Fused Silica Final Optics for Inertial Fusion Energy: Radiation Studies and System-Level Analysis
International Nuclear Information System (INIS)
The survivability of the final optic, which must sit in the line of sight of high-energy neutrons and gamma rays, is a key issue for any laser-driven inertial fusion energy (IFE) concept. Previous work has concentrated on the use of reflective optics. Here, we introduce and analyze the use of a transmissive final optic for the IFE application. Our experimental work has been conducted at a range of doses and dose rates, including those comparable to the conditions at the IFE final optic. The experimental work, in conjunction with detailed analysis, suggests that a thin, fused silica Fresnel lens may be an attractive option when used at a wavelength of 351 nm. Our measurements and molecular dynamics simulations provide convincing evidence that the radiation damage, which leads to optical absorption, not only saturates but that a 'radiation annealing' effect is observed. A system-level description is provided, including Fresnel lens and phase ...
2003-06-01
International Nuclear Information System (INIS)
Gas Distribution Companies have long paid great attention to improving the quality of gas supply service to the consumer. This has involved them in an on-going attempt to successfully define and establish a clear computer assisted replacement programme which, when drawn up on a reliability basis, may also prove cost effective. The reasons which drive any gas line replacement programme are mainly related to the necessity: to improve the gas network asset so as to face a striking expected growth in gas demand; to refurbish old distribution systems with the purpose not only to increase the reliability and continuity of gas supply but also to reduce the rate of maintenance costs due to frequent repair works; to prevent the possibility of massive replacement works for a progressing ageing of the network. This paper will present the computer assisted procedure being implemented by Italgas. It ranks well defined network areas which urgently need renewal and also have a ...
1997-06-10
Energy Technology Data Exchange (ETDEWEB)
Stainless steel is pickled in pickling bath with the sulfuric acid and a mixture of hydrofluoric acid and nitric acid. Suitable equipment based on speedy and accurate chemical analysis for actual production lines has not been developed yet. The concentration of sulfuric acid can be analyzed by using the neutralization titration method. As a method of analyzing hydrofluoric acid in the mixed acid, the iron-acetylacetone complex discoloration absorbance method was adopted. For the concentration, of nitric acid, the method of subtracting the concentration of hydrofluoric acid from the total mixed acid amounts obtained by neutralization titration is adopted. Furthermore, the iron-salicylic acid complex absorbance method is adopted as a method of analyzing the iron content. By adopting these methods, the fully automated analyzer is developed. Completing analysis work can be shortened to 40 minutes by automated sampling from the ...
1999-01-10
Energy Technology Data Exchange (ETDEWEB)
Studies of various established human bladder and renal carcinoma cell lines cultured in vitro demonstrated the presence of specific, saturable, high affinity binding sites for /sup 125/I-labeled human interferon Beta ser IFN-beta ser). This recombinant produced interferon labeled with approximately one atom of /sup 125/I/molecule of IFN expressed minimal or no loss of antiviral activity. A single class of binding sites (1000-2000/cell) with an affinity constant of 10(10)-10(11) L/M was measured at 4 degrees C for cells exhibiting widely different sensitivity to the antiproliferative effect of IFN-beta ser. Major fluctuations in the binding of /sup 125/I-labeled IFN-beta ser to cellular receptors were observed during in vitro proliferation of four of five cell lines examined. A significant decrease (P less than 0.001) in specific binding was observed 48 h after cultures were established. Cell cycle analysis suggested that ...
1987-09-01
Candoxin (PDB #1JGK), a three-finger neurotoxin from Bungarus candidus venom, inhibits post-synaptic neuromuscular and neuronal alpha7nACh-receptors, and induces delayed cell-death throughout the glial population. When applied to cultured human glial cell lines, candoxin (CDX) induced cell death in a concentration (EC(50) approximately 1muM) and time dependent manner. Results of TUNEL-histochemistry further confirm CDX-induced brain (hippocampus, frontal cortex, and temporal regions) damage when administered intracerebroventricularly (i.c.v) in adult mice. In this study, we explored differential gene expression profiles following exposure of human glial (Hs 683) cell lines to CDX at various time intervals using Affymetrix-GeneChips. By means of MAS and GeneSpring analyses, 105 genes whose expression was significantly (P<0.01) altered by at least 3-fold were selected. Results of the genome analysis reveal that the ...
2005-11-23
Age-Related Long-Term Functional Results after Riboflavin UV A Corneal Cross-Linking.
Purpose. To report a comparative prospective long-term functional analysis after Riboflavin UV A corneal cross-linking (CXL) in three different age groups of patients affected by progressive keratoconus (KC). Methods. Functional analysis comprised paediatric patients (?18 years) included 152 eyes (29.5%); intermediate group (19-26 years) 286 eyes (55.4%), and adults (?27 years) 78 eyes (15.1%). CXL was performed according to the Siena protocol by using the Vega CBM (Caporossi-Baiocchi-Mazzotta) X linker (CSO, Florence, Italy) at Siena University by the same authors. Pre- and post-op examinations included UCVA, BSCVA, corneal topography, and surface aberrometry (CSO Eye Top, Florence, Italy), at 48 months followup. Results. At 48 months followup paediatrics, intermediate, and adult patients showed a mean gain in UCVA of +0.2, +0.14 and +0.12 Snellen lines. BSCVA gained by a mean of +0.21, +0.2, and +0.1 Snellen ...
2011-08-04
When loss is more (for transmission towers) | SmartPlanet
... ice, hurricanes, and trees (less likely on high voltage transmission lines ) can bring down above ground power lines. Flooding, Leeching ground ...
Infantry Behind the Lines-Still a Viable Concept?
Page 1. S~Infantry Behind the Lines- Still A Viable Concept? A Monograph by Major Mike McMahon Infantry 4T-' School ...
1993-12-17
Central Venous Access Catheters (CVAC) and Gastrostomy (Feeding) Tubes
... of CVACs, including tunneled catheters (Hickman or Broviac), peripherally inserted central catheters (also called PICC lines or long lines), ...
An Intrinsic Baldwin Effect in the H Beta Broad Emission Line in the Spectrum of NGC 5548
We investigate the possibility of an intrinsic Baldwin effect (i.e., nonlinear emission-line
2003-01-01
Seismic stratigraphy based chronostratigraphic (SSBC) analysis of the Serbian Banat region allows the delineation of the spatial and stratigraphic relationships of the generally regressive and shallowing upward Neogene depositional fill of a tectonically unstable central portion of the Pannonian Basin. When geometrically restored in time and space, the sediment dispersal directions, sediment source directions, types of sedimentation breaks and the tectonic events influencing basin evolution can be delineated. For such an analysis the time-transgressive lithostratigraphic units used in the neighbouring Hungarian part of the Pannonian Basin are conveniently introduced based upon their characteristic seismic facies and constrained borehole log records as mappable seismic stratigraphic sequence units, termed "seismic operational sequences". The respective Neogene stage and operational sequence equivalents (Hungarian lithostratigraphic units or ...
2010-12-01
Low-friction snow plow evaluation
Energy Technology Data Exchange (ETDEWEB)
Canadian railway traffic is delayed until lines are plowed of snow following heavy snowfalls. A modification that would permit higher plowing speeds and fewer delays could realize significant benefits in addition to direct fuel and labor savings. The objective of this project was to carry out a cost benefit analysis on a low-friction coating applied to a mainline railway snow plow. The assessment was carried out using old Canadian National Railway snow plows for test purposes. An analytical model was developed to estimate the importance of friction reduction to fuel consumption and power requirements. The sensitivity analysis revealed a bump or discontinuity in the power vs speed profile, corresponding to the minimum plow speed at which the snow will cease to flow over the plow. Reducing the coefficient of friction reduces this minimum plowing speed. This could mean the difference between success and failure in plowing some ...
1988-09-01
Energy Technology Data Exchange (ETDEWEB)
This paper deals with the efficient simulation of the dynamical behaviour of molten carbonate fuel cells (MCFCs). MCFCs allow an efficient and environmentally friendly energy production via electrochemical reactions. Their dynamics can be described by large scale systems of up to currently 22 nonlinear partial differential algebraic equations (PDAE). The paper also serves as a basis for later parameter identification and optimal control purposes. Therefore, the numerical simulations are particularly based on hierarchically embedded systems of PDAE, first of all in one space dimension. The PDAE are of mixed parabolic-hyperbolic type and are completed by nonlinear initial and boundary conditions of mixed type. For a series of embedded models in one space dimension, the vertical method of lines (MOL) is used throughout this paper. For the semi-discretization in space appropriate difference schemes are applied depending on the type of equations. The resulting system of ...
2005-02-01
Energy Technology Data Exchange (ETDEWEB)
The exchange charge model (ECM) of crystal field is utilized to provide the theoretical explanation of the ground state absorption and the excited state absorption observed for the octahedrally coordinated Ni{sup 2+} ions in the spinel MgAl{sub 2}O{sub 4}. The ECM enables modeling of the crystal field parameters (CFPs) for the impurity ions based on the crystal structure data of the host lattice. To ensure the reliability of the CFPs, the convergence of the CFP values with the increasing number of the coordination spheres taken into account in the ECM calculations is considered. The trigonal CFPs B{sub 2}{sup 0},B{sub 4}{sup 0}andB{sub 4}{sup -3} determined by the ECM, together with the appropriate Racah parameters B and C, serve as input to two crystal field analysis computer packages, which compute the energy level schemes within the whole 3d{sup 8} configuration. The cubic approximation utilizing only one CFP Dq is also discussed. Basic features of the ground ...
2007-04-25
Calibration curves of a PGNAA system for cement raw material analysis using the MCNP code
Energy Technology Data Exchange (ETDEWEB)
In large samples, the {gamma}-ray count rate of a prompt gamma neutron activation analysis system is a multi-variable function of the elemental dry composition, density, water content and thickness of the material. The experimental calibration curves require tremendous laboratory work, using a great number of standards with well-known compositions. Although a Monte Carlo simulation study does not avoid the experimental calibration work, it reduces the number of experimental calibration standards. This paper is part of a feasibility study for a PGNAA system for on-line continuous characterisation of cement raw material conveyed on a belt (Oliveira, C., Salgado, J. and Carvalho, F. G. (1997) Optimisation of PGNAA instrument design for cement raw materials using the MCNP code. J. Radioanal. Nucl. Chem. 216(2), 191-198; Oliveira, C., Salgado, J., Goncalves, I. F., Carvalho, F. G. and Leitao, F. (1997a) A Monte Carlo study of the influence of ...
1998-12-01
The intrinsic nature of the Baldwin effect
The relationship between the fluxes of the two strongest UV emission lines and flux in the continuum
1992-01-01
Sustaining Operational Maneuver in the Twenty-First Century
... and the Commonwealth forces launched Operation GOODWOOD in an attempt to break through the German lines. In the ...
2010-05-13
International Science & Technology Center (ISTC)
Development of Experimental Large-scale Technology and Creation of Technological Line of Rubomicine Production
... the pulmonary vein and because there's a gap, electricity is going across the ablation line and capturing ...
Off-line and on-line-monitoring of power transformers using the transfer function method
Energy Technology Data Exchange (ETDEWEB)
The transfer function concept is well known as an additional method to evaluate the impulse test of power transformers in the test laboratory. Another application for the transfer function method is monitoring of transformers in service. Thereby, Off-line and On-line monitoring can be realized. Both kinds of monitoring are demonstrated with on-site measurements on a power transformer in service.
1996-12-31
Now try to explain network security
Overloaded transmission lines are only part of the problem. The ability of the network to carry power is also limited by the supply of reactive power and by frequency stability. Reactive power problems must be corrected in minutes, frequency stability problems in seconds. There is no way that market forces can handle these problems. Reactive power must be supplied to all long transmission and distribution lines to compensate for the loss of reactive volt-amperes - and resulting voltage drop - in the reactance along the line`s length. 7 figs.
1996-10-01
Mutation breeding in kalmia juvenile trees derived from shoot tip cultare and kobus seedlings
International Nuclear Information System (INIS)
Juvenile trees of kalmia derived from shoot tip culture, and seedlings of kobus were irradiated with #gamma#-rays. In kalmia, two mutation lines were obtained which had narrowlong leaves. In kobus two mutation lines were obtained. One mutation line has flowers with 7 to 13 petals. Another mutation line has yellow-green variegated leaves. (author).
A comparison of methods for calculating audible noise of high voltage transmission lines
Energy Technology Data Exchange (ETDEWEB)
During the last several years, audible noise produced by high voltage transmission lines in corona has emerged as an important design consideration. In this same time frame a number of different methods for calculating audible noise levels have been proposed. The methods currently available, for both ac and dc lines, are described in this paper and are compared through application to practical line geometries for which data from long-term measurements are available.
1982-10-01
Study of silicon damage caused by ultra-low energy boron implantation
International Nuclear Information System (INIS)
Ultra-shallow junction formation in deep submicron Si devices is limited by anomalous diffusion of the dopant, which is related to the release of interstitials from defect clusters formed during the implantation of energetic ions or the subsequent annealing. The work described in this dissertation is concerned with the effects of low energy B ion implantation, especially damage formation, clustering and its annealing. After a review of the stopping and ranges of energetic ions in Si, the formation of implant damage, in particular of point defects, their migration, agglomeration and annihilation, including the involvement of dopant ions, is considered. A description of the Salford ultra low energy implanter is given and the main analysis technique, medium ion energy scattering (MEIS) reviewed. Additional analytical techniques used, such as secondary ion mass spectrometry (SIMS), 4-point probe and cross section transmission microscopy (XTEM) as well as TRIM ...
Energy Technology Data Exchange (ETDEWEB)
Producing nuclear energy in order to reduce anthropic CO{sub 2} emission and to meet high energy demand, implies three conditions to the nuclear plants of the IV. generation: safety improvements, radioactive waste minimization, and fuel breeding for a sustainable use of the resources. The Thorium fuel cycle used in Molten Salt Reactors seems promising. Many numerical studies based on probabilistic codes are carried out in order to analyse the behaviour of such reactors. Nevertheless, one of the most important parameters is badly known: the alpha ratio of {sup 233}U, ratio of the neutron capture cross section to fission one for {sup 233}U. This key-parameter is necessary to calculate the breeding ratio and thus, the deployment capacities of those reactors. This Ph-D thesis was intended to prepare a precise measurement of the alpha ratio of {sup 233}U between 1 eV and 10 keV. Preliminary measurements have been performed on the experimental platform PEREN. This ...
2007-12-15
Direct Comparison of the X-Ray Emission and Absorption of Cerium Oxide
Energy Technology Data Exchange (ETDEWEB)
Bremstrahlung Isochromat Spectroscopy (BIS). The XES spectra were collected using a Specs electron gun for the excitation and the XES 350 grating monochromator and channel plate system from Scienta as the photon detection. Spectra were collected in 'normal mode,' where the electron gun kinetic energy (KE) and the energy position of the center of the channel plate were both fixed and the energy distribution in the photon (hv) spectrum was derived from the intensities distributed across the channel plate detector in the energy dispersal direction. The polycrystalline Ce sample was oxidized by exposure to air at ambient pressures. After introduction to the ultra-high vacuum system, the oxidized sample was bombarded with Ar, to clean the topmost surface region and stabilize the surface and near surface regions. Although CeO{sub 2} would be the thermodynamically preferred composition in an oxygen rich environment, the combination of a vacuum environment and ion etching may ...
2010-11-24
Selected topics in transient response of aerial lines to high-altitude electromagnetic pulse
International Nuclear Information System (INIS)
Aerial lines or cables, as one mainly energy transport path of electronic system when illuminated by HEMP, has been often modeled by field-to-transmission line model. However, in many cases, authors too often encounter some confusing statements to the lines effects during experimental procedure. The aim of this paper is to present and discuss these cases, such as the electromagnetic environment above the ground plane, the contribution of the different electromagnetic field component to the induced current and voltage, variations of the load current for different line heights and ground conductivities etc. (authors)
2005-11-01
Energy Technology Data Exchange (ETDEWEB)
Results obtained on induced current and voltage caused by a high voltage transmission lines running parallel at a trolley bus contact lines, are presented. A computer program in Basic language, was developed to calculate the electric induction, problems of safety, a theoretical development and mathematical model of the electric factors between two lines (inductor and induced) are also discussed. 11 figs., 1 tab., 8 refs.
1991-12-31
Energy Technology Data Exchange (ETDEWEB)
A detailed description is given of the design, fabrication, and installation of oil-filled 500-kV cable lines used for the first time in the USSR for transmitting electric power from step-up transformers installed several meters from the hydroelectric generators to an outdoor distribution system or a junction point at which they are connected to overhead power transmission lines. These lines are 950 to 1050 m long and they are placed at levels differing by 45 m along the route. These lines can transmit power as great as 630 MV.A.
1980-01-01
A Scheme of 3-D Breakdown-whip Analysis Methodology for High Energy Piping
Energy Technology Data Exchange (ETDEWEB)
High energy piping systems are operated with either or both conditions of maximum operating temperature exceeding 200 .deg. F(93.3 .deg. C) or maximum operating pressure exceeding 275 psig(19.3kg/cm{sup 2}) during normal operating conditions in nuclear power plants. A high energy pipe failure is postulated in branches or piping that runs larger than one inch nominal diameter. The resultant consequences of these postulated pipe breaks must be analyzed for the effect on maintenance of plant safe shutdown capability, containment integrity. And the analyzed results must be applied to the system design so that a pipe failure can not damage essential systems to an extent of impairing design function nor affect necessary component operability. The considerable effects of pipe break are as follows; dynamic effects such as pipe whip, jet impingement and environmental impact by release of system contents. Two types of forces are occurred by the pipe whip. The one is pipe whip impact force that ...
2007-10-15
XRF analysis of rock and sediment using standard rock samples
Energy Technology Data Exchange (ETDEWEB)
A simple and rapid method is described for the determination of major and trace elements in rock and sediment samples by wavelength dispersive XRF. Sample measured were made from cellulose powder pressed into 4 cm diameter aluminium ring 0.4 t cm/sup -2/, and then 1 g of powdered sample (0.08 g cm/sup -2/) was placed on the disk and repressed at 1.6 t cm/sup -2/. X-ray measurements were performed for total XRF intensity (I/sub p/) at the characteristic line of each element and background intensity (I/sub b/) in vicinity of the line. The correction of matrix effect was achieved by X-ray intensity ratio of peak to background for each element. Eight standard rock samples from Geological Survey of Japan were used as standard materials, and linear calibration curves were obtained by the plot of I/sub p/ - I/sub b/ vs. concentration for Ca, Na and Pb and by the plot of I/sub p//I/sub b/ ratio vs. concentration for Si, Fe, Ti, K, P, Cl, Cr, Mn, Ni, ...
1987-03-01
XRF analysis of rock and sediment using standard rock samples
International Nuclear Information System (INIS)
A simple and rapid method is described for the determination of major and trace elements in rock and sediment samples by wavelength dispersive XRF. Sample measured were made from cellulose powder pressed into 4 cm diameter aluminium ring 0.4 t cm"-"2, and then 1 g of powdered sample (0.08 g cm"-"2) was placed on the disk and repressed at 1.6 t cm"-"2. X-ray measurements were performed for total XRF intensity (I_p) at the characteristic line of each element and background intensity (I_b) in vicinity of the line. The correction of matrix effect was achieved by X-ray intensity ratio of peak to background for each element. Eight standard rock samples from Geological Survey of Japan were used as standard materials, and linear calibration curves were obtained by the plot of I_p - I_b vs. concentration for Ca, Na and Pb and by the plot of I_p/I_b ratio vs. concentration for Si, Fe, Ti, K, P, Cl, Cr, Mn, Ni, Cu, Zn, Pb, Sr and Ba, respectively. The ...
Optical Properties and Wave Propagation in Semiconductor-Based Two-Dimensional Photonic Crystals
Energy Technology Data Exchange (ETDEWEB)
This work is a theoretical investigation on the physical properties of semiconductor-based two-dimensional photonic crystals, in particular for what concerns systems embedded in planar dielectric waveguides (GaAs/AlGaAs, GaInAsP/InP heterostructures, and self-standing membranes) or based on macro-porous silicon. The photonic-band structure of photonic crystals and photonic-crystal slabs is numerically computed and the associated light-line problem is discussed, which points to the issue of intrinsic out-of-lane diffraction losses for the photonic bands lying above the light line. The photonic states are then classified by the group theory formalism: each mode is related to an irreducible representation of the corresponding small point group. The optical properties are investigated by means of the scattering matrix method, which numerically implements a variable-angle-reflectance experiment; comparison with experiments is also provided. The ...
2002-12-31
Energy Technology Data Exchange (ETDEWEB)
This paper describes the calculation method of 3-D underground structures in TDME method which measures only field components. Recently, FDTD method was developed as calculation method in time domain difference calculus, and the forward analysis accuracy of 3-D fields was rapidly improved. The survey results using a large-scale loop (600m{times}360m) were numerically analyzed by FDTD method. 16 measuring lines were prepared in both X and Y directions, and measuring points were prepared on intersection points of the measuring lines. Since signal current is staircase one, step and impulse responses of the ground were determined by calculating magnetic field and its time differentiation. The rectangular body (120m{times}120m{times}100m) of 0.2S/m in conductivity (5 ohm m in resistivity) was installed 160m under the ground as 3-D resistivity anomaly. The ground of 0.01S/m (100 ohm m) was assumed. Time variation in horizontal ...
1996-10-01
Multiphase treatment of ODTX in HMX spheres
Energy Technology Data Exchange (ETDEWEB)
What will be discussed in this report represents a framework upon which multiphase and other real physical effects can be built. Chemical models of increasing complexity are envisioned and this methodology can provide a tool for evaluating new ideas against known experimental data. The recent work to be reported here addresses the multiphase issue of temperature deviation between phases undergoing chemical and heat transport processes. Modeling of the LLNL ODTX experiment will be performed with FLUENT, a commercially available computational fluid dynamics (CFD) code. FLUENT solves flows in 2D or 3D in Cartesian, cylindrical, or general curvilinear coordinates, with steady-state of fully time-dependent analysis. Multiphase flows in which two or more continuous phases are present can be solved with arbitrary volumetric sources of heat, mass, momentum, and chemical species applied through user-defined FORTRAN subroutines. FLUENT models these of phenomena by solving ...
1997-12-22
Molecular events involved in ionizing radiation induced skin carcinogenesis
International Nuclear Information System (INIS)
The process of mouse skin tumor formation is subdivided into three operational stages. These stages include initiation, promotion and progression. Ionizing radiation has been found to be a weak initiating agent in the production of malignant squamous cell carcinomas, a complete carcinogen and an agent effective in causing tumor progression. Four skin tumor histologies have been seen with ionizing radiation: benign papillomas, squamous (SCC) and basal (BCC) cell carcinomas and fibrosarcomas. Distinct non-ras transforming genes have been detected in radiation initiated SCCs. A benign papilloma cell line (308) was used as a model system to study ionizing radiation induced progression. A variant 308 cell line (308 10 Gy 5) derived by irradiation of the parental 308 cell has been characterized. The 308 10 Gy 5 cells unlike the parental 308 cells from malignant tumors in athymic nude mice upon subcutaneous injection. The variant 308 10 Gy 5 cells ...
Equatorial scintillation model. Technical report, 1 February 1983-30 April 1985
Energy Technology Data Exchange (ETDEWEB)
Radiowave scintillation in the presence of natural and/or high-altitude nuclear disturbances has the potential to disrupt numerous transionospheric radio and radar systems. This report develops a model characterizing the plasma-density irregularities that produce scintillation in the naturally disturbed equatorial F layer. The model is incorporated into Program WBMOD along with subroutines for computing both link geometry and scintillation indices, the latter by means of phase screen diffraction theory. The model is based on similarly extensive analysis of wideband data from two equatorial stations. It describes irregularities at an effective height of 350 km that are isotropic across the geomagnetic field and elongated by a factor of 50 along the field and whose one-dimensional spatial power spectrum obeys a single-regime power law with a (negative) spectral index of 1.5. The height-integrated spectral strength of the irregularities is modeled as a function of ...
1985-09-30
Development of a neutron/. gamma. ray radiation monitor
Energy Technology Data Exchange (ETDEWEB)
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/..gamma.. ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time ..gamma.. spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded ..gamma.. spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations ...
1983-01-01
Development of a neutron/#gamma# ray radiation monitor
International Nuclear Information System (INIS)
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/#gamma# ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time #gamma# spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded #gamma# spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations using ...
1983-01-01
Development of a Neutron/gamma Ray Radiation Monitor.
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/gamma ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time gamma spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded gamma spectra created by the photopeak-compton edge combination in the plateau portion of the knee response, correcting equations using a ...
1983-01-01
Densification behavior and properties of Y_2O_3-containing #alpha#-SiAlON-based composites
International Nuclear Information System (INIS)
Different SiAlON composites based on #alpha#'-SiAlON are investigated, with respect to the phase relationships, densification behavior, and mechanical properties. The compositions are located on a phase-diagram line parallel to the Si_3N_4-Y_2O_3#centre dot#9AlN compound in the Si_3N_4-SiO_2-AlN-Al_2O_3-Y_2O_3-YN system. Analysis of the reaction sequences shows that the formation of the composites is associated with the transient appearance of Y_4Al_2O_9 (YAM), yttrium-aluminum-garnet (YAG), melilite, and a nitrogen-rich liquid phase. The small shift of compositions on the Si_3N_4-Y_2O_3#centre dot#9AlN compound phase-diagram line toward the Al_2O_3-rich side offers the advantage of a higher sinterability and the removal of the melilite phase from a wide range of compositions containing #alpha#'-SiAlON and polytypes. The #alpha#'/#beta#'-SiAlON composites show better mechanical properties in comparison to pure ...
International Nuclear Information System (INIS)
Recent advances in self-amplified spontaneous emission (SASE) experiments stimulate interest in quantitative comparison of measurements with theory. In this paper we show that the widely used simulation code TDA3D, developed by Tran and Wurtele [Comput. Phys. Commun. 54, 263 (1989)] even though a single frequency code, can be used to determine the output power in the SASE process with excellent approximation in the exponential growth regime. The method applies when the gain is not very high, which is a special advantage, because when the gain is not very high, the analytical calculation is particularly difficult since the exponential growing term does not dominate. The analysis utilizes a scaling relation between the output power and the number of simulation particles in the code TDA3D: left-angle P right-angle=N_#lambda#"'/N_#lambda# left-angle P"'right-angle, where left-angle P right-angle is the output power and N_#lambda# is the line ...
1998-10-01
Bound states in the quantum scalar electrodynamics
International Nuclear Information System (INIS)
The next relativistic correction to #alpha# to for bound state mass of two charged scalar particles is calculated in the quantum scalar electrodynamics by the functional integral method. Contribution of the ''nonphysical'' time variable turned out to be important and leads to nonanalytic dependence of the bound state mass on #alpha#. In conclusion, one can say that the functional approach is the best mathematical representation to preserve the gauge invariance. The lowest approximation of this functional representation is the pure nonrelativistic Feynman path integral representation of the nonrelativistic Schroedinger equation. The functional integral representation shows that any regular series for next corrections to #alpha# does not exist and these corrections cannot be reduced to some terms of the nonrelativistic potential in the Schroedinger picture. In other words, the ''nonphysical'' time coordinate is important and leads to corrections which are not analytic at the point ...
A wavelet-fuzzy combined approach for classification and location of transmission line faults
Energy Technology Data Exchange (ETDEWEB)
This paper presents a real-time wavelet-Fuzzy combined approach for digital relaying. The algorithm for fault classification employs wavelet multi resolution analysis (MRA) to overcome the difficulties associated with conventional voltage and current based measurements due to effect of factors such as fault inception angle, fault impedance and fault distance. The proposed algorithm for fault location, different from conventional algorithms that are based on deterministic computations on a well-defined model to be protected, employs wavelet transform together with fuzzy logic. The wavelet transform captures the dynamic characteristics of the non-stationary transient fault signals using wavelet MRA coefficients. The fuzzy logic is employed to incorporate expert evaluation through fuzzy inference system (FIS) so as to extract important features from wavelet MRA coefficients for obtaining coherent conclusions regarding fault location. Computer simulations using MATLAB ...
2007-11-15
A lateral cephalometric study of the size of tongue and intermaxillary space in Korean
International Nuclear Information System (INIS)
A study was performed to investigate the size of tongue area and intermaxillary space area, and compare the sexual differences between normal Korean children and adults by introducing planimetric and linear analysis of the lateral cephalograms. The cephalograms were composed of 41 child male aged 10.8, 40 child female aged 10.5, 38 adult male aged 21.3 , and 40 adult female aged 20.8 respectively. In order to study and measure the intermaxillary space area, the following were selected, as reference items: occlusal plane, anterior intermaxillary space height, posterior intermaxillary space height, length of intermaxillary space. Among those reference items anterior intermaxillary space height and posterior intermaxillary space height were perpendicular to the maxillary plane. An index, (Anterior intermaxillary space height + posterior intermaxillary space height )/2 Length of intermaxillary space, was introduced for the calculation of intermaxillary space area. ...
1977-11-01
A human breast cell model of pre-invasive to invasive transition
Energy Technology Data Exchange (ETDEWEB)
A crucial step in human breast cancer progression is the acquisition of invasiveness. There is a distinct lack of human cell culture models to study the transition from pre-invasive to invasive phenotype as it may occur 'spontaneously' in vivo. To delineate molecular alterations important for this transition, we isolated human breast epithelial cell lines that showed partial loss of tissue polarity in three-dimensional reconstituted-basement membrane cultures. These cells remained non-invasive; however, unlike their non-malignant counterparts, they exhibited a high propensity to acquire invasiveness through basement membrane in culture. The genomic aberrations and gene expression profiles of the cells in this model showed a high degree of similarity to primary breast tumor profiles. The xenograft tumors formed by the cell lines in three different microenvironments in nude mice displayed metaplastic phenotypes, including ...
2008-03-10
Variability and spectral modeling of the hard X-ray emission of GX 339-4 in a bright low/hard state
We study the high-energy emission of the Galactic black hole candidate GX 339-4 using INTEGRAL/SPI and simultaneous RXTE/PCA data. By the end of January 2007, when it reached its peak luminosity in hard X-rays, the source was in a bright hard state. The SPI data from this period show a good signal to noise ratio, allowing a detailed study of the spectral energy distribution up to several hundred keV. As a main result, we report on the detection of a variable hard spectral feature (>150 keV) which represents a significant excess with respect to the cutoff power law shape of the spectrum. The SPI data suggest that the intensity of this feature is positively correlated with the 25 - 50 keV luminosity of the source and the associated variability time scale is shorter than 7 hours. The simultaneous PCA data, however, show no significant change in the spectral shape, indicating that the source is not undergoing a canonical ...
2010-01-01
International Nuclear Information System (INIS)
We have investigated the characteristics of ion-beam-induced spontaneous etching (IBISE) of GaAs in Cl_2 ambient by using a Ga-focused ion beam (FIB) with an energy ranging from 3 to 15 keV. The etched depth of the irradiated region was more than 20 times greater than that of unirradiated region. When the sputtered depth by FIB irradiation amounted to around 8 A at each ion energy, the etched depth in Cl_2 ambient for 1 hour became saturated. The saturated etched depths were 450, 550, 750 and 800 A at the ion energy of 3, 5, 10 and 15 keV, respectively. The residual damage of the etched surface was also investigated by photoluminescence (PL) measurement. The maximal PL intensity was obtained at around the threshold dose of IBISE and increased with decreasing ion energy. The full recovery of PL intensity was observed at the ion energy of 3 keV after annealing at 400degC. (author).
Energy Technology Data Exchange (ETDEWEB)
The reduction of transient enhanced diffusion (TED) with reduced implantation energy has been investigated and quantified. A fixed dose of 1{times}10{sup 14} cm{sup {minus}2} Si{sup +} was implanted at energies ranging from 0.5 to 20 keV into boron doping superlattices and enhanced diffusion of the buried boron marker layers was measured for anneals at 810, 950, and 1050{degree}C. A linearly decreasing dependence of diffusivity enhancement on decreasing Si{sup +} ion range is observed at all temperatures, extrapolating to {approximately}1 for 0 keV. This is consistent with our expectation that at zero implantation energy there would be no excess interstitials from the implantation and hence no TED. Monte Carlo modeling and continuum simulations are used to fit the experimental data. The results are consistent with a surface recombination length for interstitials of {lt}10 nm. The data presented here demonstrate that in the range of annealing ...
1997-11-01
International Nuclear Information System (INIS)
The reduction of transient enhanced diffusion (TED) with reduced implantation energy has been investigated and quantified. A fixed dose of 1x10"1"4 cm"-"2 Si"+ was implanted at energies ranging from 0.5 to 20 keV into boron doping superlattices and enhanced diffusion of the buried boron marker layers was measured for anneals at 810, 950, and 1050 degree C. A linearly decreasing dependence of diffusivity enhancement on decreasing Si"+ ion range is observed at all temperatures, extrapolating to #approx#1 for 0 keV. This is consistent with our expectation that at zero implantation energy there would be no excess interstitials from the implantation and hence no TED. Monte Carlo modeling and continuum simulations are used to fit the experimental data. The results are consistent with a surface recombination length for interstitials of <10 nm. The data presented here demonstrate that in the range of annealing temperatures of interest for p-n ...
Nanoporous structure formations on germanium surfaces by focused ion beam irradiations
International Nuclear Information System (INIS)
The formation of porous structures of nanometre size (nanoporous structures) on germanium (Ge) surfaces by focused ion beam (FIB) irradiations was investigated using various FIB conditions such as ion species, irradiation energies, total fluences, fluence rates, and incident angles. FIB-irradiated regions were observed using a scanning electron microscope and an atomic force microscope. It is found that, using a focused Ga ion beam (Ga FIB) at an energy of 100 keV, the irradiated Ge surface swelled up to ion fluence of 2 x 10"1"7 cm"-"2 with nanoporous structures and then was etched for larger fluences. The shape of swollen nanoporous structures depended on the fluence rate and the incident angle of the Ga FIB. However, such porous structures were observed neither for low-energy (15-30 keV) FIB irradiations using Si and Au ions nor for high-energy (200 keV), heavy ion (Au) irradiation. These observations might be helpful in ...
2007-11-07
Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization
Energy Technology Data Exchange (ETDEWEB)
The measurements of the K X-ray intensity ratio I(K{alpha} {sub 2}/K{alpha} {sub 1}), I(K{beta} {sub 1}/K{alpha} {sub 1}) and I(K{beta}/K{alpha}) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a {sup 241}Am and 123.6 keV {gamma}-rays from a {sup 60}Co were used, and following the radioactive decay of {sup 51}Cr, {sup 55}Fe, {sup 67}Ga, {sup 99}Tc, {sup 111}In, {sup 131}I, {sup 133}Ba, {sup 133}Xe, {sup 137}Cs, {sup 201}Tl and {sup 226}Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.
2007-01-15
Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization
International Nuclear Information System (INIS)
The measurements of the K X-ray intensity ratio I(K#alpha# _2/K#alpha# _1), I(K#beta# _1/K#alpha# _1) and I(K#beta#/K#alpha#) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV #gamma#-rays from a "2"4"1Am and 123.6 keV #gamma#-rays from a "6"0Co were used, and following the radioactive decay of "5"1Cr, "5"5Fe, "6"7Ga, "9"9Tc, "1"1"1In, "1"3"1I, "1"3"3Ba, "1"3"3Xe, "1"3"7Cs, "2"0"1Tl and "2"2"6Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
The peak flux relationship between hard X-rays and microwaves from solar flares is studied using about 400 events simultaneously recorded with the hard X-ray burst spectrometer on the SMM satellite and the Nobeyama 17 GHz radiometer. The data indicate that the hard X-ray and microwave peak fluxes correlate best for X-ray energies of less than about 80 keV for impulsive flares and greater than about 360 keV for extended flares. By postulating that electrons responsible for microwave emission at 17 GHz are those emitting hard X-rays at these photon energies, it is concluded that: (1) in impulsive flares, microwaves at about 20 GHz are emitted mainly by electrons of less than about 200 keV from a layer through which the electrons stream down into the thick-target hard X-ray source; and (2) in extended flares, microwaves are emitted mainly by MeV electrons trapped in a coronal loop or loops. 59 references.
1988-01-01
X-ray microanalysis of Al/Zr multilayers in the transmission electron microscope
International Nuclear Information System (INIS)
A one-nanometer scale transmission electron microscope electron probe X-ray microanalysis characterization of as-deposited and annealed aluminum--11.5 at.% zirconium multilayer samples in cross-section synthesized by magnetron sputtering is reported on here. Composition line profiles were acquired across Zr layers in as-deposited material and samples isochronally annealed in a differential scanning calorimeter to temperatures of 290 C and 485 C. A spatial resolution of approximately 1.5 to 2.0 nm was achieved in these experiments and will be improved by deconvolution of the instrumental electron probe function from the data. The as-deposited structure consisted of crystalline Al and Zr layers with thin amorphous layers at the Al/Zr interfaces. The amorphous interface layers increased in thickness upon annealing to 290 C. Additionally, at 290 C a metastable cubic alloy forms at the Zr deposited on Al interface. Upon heating to 485 C a multilayer of Al and metastable ...
1997-04-04
Energy Technology Data Exchange (ETDEWEB)
The author discusses the implementation in Germany of the EC Directive on Environmental Impact Statements in the light of the legal tradition and concepts of law in Germany, especially in the context of the nuclear licensing procedure. His analysis reveals some legal provisions and legal concepts in existing German law that will have to be ``sacrificed`` in order to do justice to the European Union, as in the formation of the body of EC law governing environmental issues, the Anglo-Saxon approach to regulatory law has been the prevailing line of orientation (the EU ecological audit being an example). On the whole, however, the implementation of the EU Directive will not lead to substantial changes beyond procedural modifications. (HP) [Deutsch] Der Autor diskutiert die Umsetzung der EG-Richtlinien in deutsche Rechtstraditionen und -vorstellungen, besonders beim atomrechtlichen Genehmigungsverfahren. Dabei seien Abstriche an deutsche ...
1995-12-31
TART97. A Coupled Neutron-Photon 3-D Combinatorial Geometry Monte Carlo Transport Code
TART97 is a coupled neutron-photon, 3 dimensional, combinatorial geometry, time dependent Monte Carlo transport code. This code can run on any modern computer. It is a complete system to assist you with input preparation, running Monte Carlo calculations, and analysis of output results. TART97 is also incredibly fast: if you have used similar codes, you will be amazed at how fast this code is compared to other similar codes. Use of the entire system can save you a great deal of time and energy. TART 97 is distributed on CD. This CD contains on-line documentation for all codes included in the system, the codes configured to run on a variety of computers, and many example problems that you can use to familiarize yourself with the system. TART97 completely supersedes all older versions of TART, and it is strongly recommended that users only use the most recent version of TART97 and ist data files.
1997-11-22
Subcellular distribution of ryanodine receptors in the cardiac muscle of carp (Cyprinus carpio).
We examined the subcellular localization of ryanodine receptors (RyR) in the cardiac muscle of carp using biochemical, immunohistochemical, and electron microscopic methods and compared it with those of rats and guinea pigs. To achieve this goal, an anti-RyR antibody was newly raised against a synthetic peptide corresponding to an amino acid sequence that was conserved among all sequenced RyRs. Western blot analysis using this antibody detected a single RyR band following the SDS-PAGE of sarcoplasmic reticulum (SR) membranes from carp atrium and ventricle as well as from mammalian hearts and skeletal muscles. The carp heart band had slightly greater mobility than those of mammalian hearts. Although immunohistochemical staining showed evident striations corresponding to the Z lines in longitudinal sections of mammalian hearts, clusters of punctate staining, in contrast, were distributed ubiquitously throughout carp atrium and ventricle. Electron ...
2003-06-12
British Library Electronic Table of Contents (United Kingdom)
Potassium dichlorido(l-prolinato)platinate(II), K[PtCl"2(l-pro"?"H)] (1), and chlorido(dimethyl sulfoxide)(l-prolinato)platinum(II), [PtCl(l-pro"?"H)(dmso)] (2), were synthesized by ligand substitution reactions. Both complexes were characterized by ^1H, ^1^3C, and ^1^9^5Pt NMR spectroscopy, elemental analysis, and HR-ESI-MS. The molecular structures of 1 and 2 were determined by single crystal X-ray diffraction, proving bidentate coordinated l-prolinato ligand and SP-4-4 configuration of 2a. With the help of DFT calculations stability of possible isomers of 1 and 2 was studied. A considerable difference in the in vitro cytotoxicity of 1 versus 2a (exchange of one chlorido ligand by dmso) against four human cancer cell lines was found.
2011-01-01
String Junctions and Holographic Interfaces
In this paper we study half-BPS type IIB supergravity solutions with multiple $AdS_3\\times S^3\\times M_4$ asymptotic regions, where $M_4$ is either $T^4$ or $K_3$. These solutions were first constructed in [1] and have geometries given by the warped product of $AdS_2 \\times S^2 \\times M_4 $ over $\\Sigma$, where $\\Sigma$ is a Riemann surface. We show that the holographic boundary has the structure of a star graph, i.e. $n$ half-lines joined at a point. The attractor mechanism and the relation of the solutions to junctions of self-dual strings in six-dimensional supergravity are discussed. The solutions of [1] are constructed introducing two meromorphic and two harmonic functions defined on $\\Sigma$. We focus our analysis on solutions corresponding to junctions of three different conformal field theories and show that the conditions for having a solution charged only under Ramond-Ramond three-form fields reduce to relations involving the ...
2010-01-01
Sensitivity of dual fuel engine combustion and knocking limits to gaseous fuel composition
International Nuclear Information System (INIS)
Combustion noise, knock and ignition limits data are measured and presented for a dual fuel engine running on dual fuels of Diesel and three gaseous fuels separately. The gaseous fuels used are liquefied petroleum gas, pure methane and compressed natural gas mixture. The maximum pressure rise rate during combustion is presented as a measure of combustion noise, and the knocking and ignition limits are presented as torque output at the onset of knocking and ignition failure. Experimental investigation on the dual fuel engine revealed the noise generated from combustion, knocking and ignition limits for all gases at different design and operating conditions. A Ricardo E6 Diesel version engine is converted to run on dual fuel of Diesel and the tested gaseous fuel and is used throughout the work. The engine is fully computerized, and the cylinder pressure data, crank angle data and engine operating variables are stored in a PC for off line ...
2004-02-01
Results of in-house cone-cup testing of low to high temperature SPF-alloys
Energy Technology Data Exchange (ETDEWEB)
Material testing of SPF-sheet is usually done with coupon hot tensile testing. The optimum range of strain rates is determined with stepped strain tests. To overcome the problem of very few available testing facilities and time consuming and costly procedure, cone cup testing has been developed since long. This test can be generated directly in the workshop, no machining of samples is necessary and it is very much related to the real SPF-process. The analysis of suitable temperature and strain rate is done by simple measurement of resulting cone height. This paper describes a unique and novel variant of the above mentioned baseline design. It provides on-line data of the actual status of the cone cup forming resulting from the applied, constant pressure. Strain rate variations as a result from texture or from the alloy-related behaviour is detectable. Thinning and ''hardening'' behaviour of different alloys ...
2004-07-01
Energy Technology Data Exchange (ETDEWEB)
One aspect of the research program SFB 570 'Distortion engineering' is the in situ X-Ray diffraction analysis of phases and residual stresses during complete heat treatment cycles. These investigations result in experimental evidence available for the extensive computations. The optimisation of the instrumentation will be reported. A surface decarburisation of samples made from the ball bearing steel 100Cr6 could be avoided for a temperature range from 800 to 900 C and a holding time of one hour by a combination of evacuate the furnace and using a certain nitrogen flow as protective gas. At lower temperatures small amounts of ferrite caused by an increased diffusion rate of carbon lead again to a surface decarburisation up to a depth of 2 {mu}m. It was proved that with an evacuation of the X-Ray beam path at constant power of the X-Ray source the intensity of diffraction lines could be increased by more than a factor of 4. The ...
2007-07-01
Radiation-induced mutations at mouse hemoglobin loci
International Nuclear Information System (INIS)
In experiments designed to detect new mutations affecting hemoglobin, we irradiated the male or female parent in reciprocal crosses of two mouse strains that differ in alleles at the hemoglobin (Hba, Hbb) loci as well as at five other specific loci. Offspring were analyzed for hemoglobin properties (electrophoretic pattern, solubility, crystal pattern), serum albumin differences, erythrocyte lysis, reticulocyte count, and external appearance. Five hemoglobin variants were found among the mutants. In three, the genetic contribution from the irradiated father was not expressed with regard to the #alpha#-chain; one carried a tandem duplication (the first known case in the mouse) involving Hbb; and one probably resulted from double nondisjunction of chromosome 7. The finding that major chromosome aberratios can mimic hemoglobin mutations indicates the need, in similar experiments, to follow F_1 screening with thorough cytogenetic analysis. The variants in which there ...
The statistical properties of the bid-ask spread of a frequently traded Chinese stock listed on the Shenzhen Stock Exchange are investigated using the limit-order book data. Three different definitions of spread are considered based on the time right before transactions, the time whenever the highest buying price or the lowest selling price changes, and a fixed time interval. The results are qualitatively similar no matter linear prices or logarithmic prices are used. The average spread exhibits evident intraday patterns consisting of a big L-shape in the morning and a small L-shape in the afternoon. The distributions of the spread with different definitions decay as power laws. The tail exponents of spreads at transaction level are well within the interval $(2,3)$ and that of average spreads are well in line with the inverse cubic law for different time intervals. Based on the detrended fluctuation analysis, we find evidence of long memory in ...
2006-01-01
Probabilistic fracture assessment of TAPP 3-4 PHT piping
International Nuclear Information System (INIS)
Methodology based on probabilistic fracture mechanics (PFM) is finding increasing acceptability in demonstrating safety of Nuclear Power Plant (NPP) piping. In PFM, the methods of fracture mechanics and reliability theory are combined for assessing the reliability of components, which contain cracks. In this work, reliability assessment of Tarapur Atomic Power Plant (TAPP) 3-4 Primary Heat Transport (PHT) piping is done using PFM. Monte Carlo simulation with stratified sampling is used as a variance reduction technique. PFM model assumes a pre-existing circumferential surface crack before the start of plant operation. The crack grows in size during the lifetime of the plant due to the fatigue loading. This part-through wall crack having escaped hydro-test and pre-service inspection, may result in either a through wall flaw (leak) or may lead to the rupture of the piping. R6 method is used as failure criteria. Steam generator inlet (SGI), steam generator outlet (SGO) and pump discharge ...
2005-12-01
Energy Technology Data Exchange (ETDEWEB)
High spin states of the proton rich nuclei in the mass region A {approx} 100 have been studied at the GASP spectrometer through the evaporation of light charged particles and heavier ions detected in the 4{pi} Si-ball Isis. Rear side injection and pulse shape analysis have allowed a good discrimination among protons, alpha particles and heavy ions up to C. Of the several nuclei populated in the reactions we will discuss here the high spin states of {sup 105} Sn. In addition to an extension of the spherical level, scheme, a regular sequence of dipole transitions has been found, The states of the dipole band are suggested to be built on a neutron h{sup 2}{sub 11/2} excitation coupled to proton particle-hole states, which polarize the core to a slightly prolate shape. The experimental results are in agreement with the prediction of tilted axis cranking calculations, which satisfactorily explain the properties of the band. (author) 17 refs., 4 figs.
1997-12-31
Galactic open clusters are since long recognized as one of the best tools for investigating the radial distribution of iron and other metals. We employed FLAMES at VLT to collect UVES spectra of bright giant stars in a large sample of open clusters, spanning a wide range of Galactocentric distances, ages, and metallicities. We present here the results for four clusters: Berkeley 20 and Berkeley 29, the two most distant clusters in the sample; Collinder 261, the oldest and the one with the minimum Galactocentric distance; Melotte 66. Equivalent width analysis was carried out using the spectral code MOOG and Kurucz model atmospheres to derive abundances of Fe, Al, Mg, Si, Ca, Ti, Cr, Ni, Ba; non-LTE Na abundances were derived by direct line-profile fitting. We obtain subsolar metallicities for the two anticenter clusters Be 20 ([Fe/H]=-0.30, rms=0.02) and Be 29 ([Fe/H]=-0.31, rms=0.03), and for Mel 66 ([Fe/H]=-0.33, rms=0.03), located in the ...
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
A KEK-PS experiment E337 `Angular correlation of intermediate mass fragments emitted from the target multifragmentation reactions with 12 GeV protons` is an extension of the E288 performed a few years ago. The E288 revealed that the proton-induced target multifragmentation reactions at 12 GeV showed quite interesting phenomena such as 70 degree peaking angular distributions for intermediate mass fragments. In December, 1955, the test experiment with 12 GeV protons was started at KEK using this newly constructed counter array of 37 Bragg Curve Counters. The main production experiment was performed in April and May in 1996 after debugging the new counter system and DAQ system, as well as EP1-B beam line. Data with Au, Tm, Sm and Ag targets were successfully accumulated. The data are in the analysis stage, and several interesting features of high energy nuclear reactions have already been seen. (G.K.)
1997-05-01
NOVA Corporation of Alberta annual report, 1992
International Nuclear Information System (INIS)
Nova Corporation and its related businesses are involved in natural gas production, gas pipelines, consulting services, and upgrading of natural gas into chemicals and plastics. Nova owns Alberta Gas Transmission Division, the primary gas transportation system in Alberta, with 11,400 miles of pipeline and total deliveries in 1992 of 3.4 trillion ft"3. Nova also owns 50% of Foothills Pipe Lines Ltd., one of Canada's largest carriers of exported gas, and 50% of TQM Pipeline Partnership, which transports natural gas in Quebec. Nova conducts its chemicals business through Novacor Chemicals Ltd., which has plants in Alberta, Ontario, Quebec, and the USA. Novacor's major petrochemicals are methanol, ethylene, propylene, and styrene and its major plastics are polystyrene, polypropylene, and polyethylene. Nova's gas-producing branch Novalta Resources produced 26 billion ft"3 of natural gas in 1992 and has proven reserves of 334 billion ft"3. Nova's net income in 1992 was ...
British Library Electronic Table of Contents (United Kingdom)
Cytoplasmic male sterility (CMS) is a maternally inherited trait that fails to produce functional pollen grains. The CMS system is widely employed to facilitate the utilization of heterosis in major crops. However, little is known about the CMS associated genes in Upland cotton (Gossypium hirsutum). The objective of this study was to compare CMS cotton (CMS-D2) with the cytoplasm from G. harknessii and its isogenic maintainer line with the normal fertile Upland cotton cytoplasm to identify CMS-D2 specific gene(s) and to develop CMS-specific sequence characterized amplified region (SCAR) markers. Based on Southern blot analysis using 10 mitochondrial gene-specific probes (cob, cox2, atp6, atp9, nad3, cox3, atpA, cox1, nad6 and nad9), three probes (cox3, atpA, and nad6) revealed restriction ...
2011-01-01
Mid infrared observations of Van Maanen 2: no substellar companion.
Energy Technology Data Exchange (ETDEWEB)
The results of a comprehensive infrared imaging search for the putative 0.06 M{sub {circle_dot}} astrometric companion to the 4.4 pc white dwarf van Mannen 2 are reported. Adaptive optics images acquired at 3.8 {micro}m reveal a diffraction limited core of 0.09 inch and no direct evidence of a secondary. Models predict that at 5 Gyr, a 50 M{sub J} brown dwarf would be only 1 magnitude fainter than van Maanen 2 at this wavelength and the astrometric analysis suggested a separation of 0.2 inch. In the case of a chance alignment along the line of sight, a 0.4 mag excess should be measured. An independent photometric observation at the same wavelength reveals no excess. In addition, there exist published ISO observations of van Maanen 2 at 6.8 {micro}m and 15.0 {micro}m which are consistent with photospheric flux of a 6750 K white dwarf. If recent brown dwarf models are correct, there is no substellar companion with T{sub eff} {approx}> 500 ...
2004-11-03
Micropatterned polysaccharide surfaces via laser ablation for cell guidance
Energy Technology Data Exchange (ETDEWEB)
Micropatterned materials were obtained by a controlled laser ablation of a photoimmobilised homogeneous layer of hyaluronic acid (Hyal) and its sulphated derivative (HyalS). The photoimmobilisation was performed by coating the polysaccharide, adequately functionalised with a photoreactive group, on aminosilanised glass substrate and immobilising it on the surface under UV light. Hyal or HyalS photoimmobilised samples were then subjected to laser ablation with wavelengths in the UV regions in order to drill the pattern. Four different patterns with stripes of 100, 50, 25 and 10 {mu}m were generated. A chemical characterisation by attenuated total reflection/Fourier transform infrared (ATR/FT-IR) and time of flight-secondary ions mass spectrometry (TOF-SIMS) confirmed the success of the laser ablation procedure and the presence of alternating stripes of polysaccharide and native glass. The exact dimensions of the stripes were determined by atomic force microscopy. The ...
2003-03-03
MTF analysis of the MURR real-time neutron radiography facility
International Nuclear Information System (INIS)
In neutron radiography, as in other forms of NDE, it is sometimes desirable to observe dynamic events. This need has generated increased interest in real-time neutron radiography systems. As in other forms of radiography, a standard method for measuring the image forming capability of real-time systems is necessary in order to compare the various methods and systems used. A technique which has been used extensively in general photography and has been applied in the characterization of several screen-film combinations used in conventional neutron radiography is to determine the imaging system's modulation transfer function (MTF). This gives a graphical representation of the system's spatial resolution capabilities and was therefore chosen as the method for evaluation of the real-time neutron radiography facility at the University of Missouri Research Reactor (MURR). The method used was to image a knife-edge, differentiate the edge gradient to obtain the line spread ...
1982-04-01
Energy Technology Data Exchange (ETDEWEB)
Using a Q3D magnetic spectrometer the elastic and inelastic scattering of /sup 12/C on /sup 88/Sr and the neutron pick-up (/sup 12/C, /sup 13/C) has been studied. The spin alignment of the inelastically excited 2/sup +/ state of /sup 12/C (4.43 MeV) has been deduced from the line shapes broadened by the ..gamma..-decay in flight. Thus for each m-substate a full angular distribution was obtained. The m = 1 substate shows a shifted interference minimum, which is explained by the different strength of the Coulomb and nuclear amplitudes in the m-substates. The analysis of the data on elastic scattering, inelastic scattering, alignment and the neutron transfer can be described consistently with one choice of the optical model parameters.
1982-04-01
Including the relativistic kinetic energy in a spline-augmented plane-wave band calculation
International Nuclear Information System (INIS)
The first-order relativistic correction to the kinetic energy of an electron, the mass-velocity term, is not bounded from below. It can, therefore, not be used within a variational framework. To overcome this deficiency we developed a method to include the entire relativistic kinetic energy #sq root#(p"2c"2+m_0"2c"4)-m_0c"2 in a spline-augmented plane-wave band calculation. The first results for silver are quite promising, especially for d and p states: The analysis of the energies of the core states as well as of the valence band structure suggests that the energies of d bands are reproduced within 1 mRy. However, the combination of the relativistic kinetic energy with the Darwin term leads to energies which are too low for s-like valence states by 10 mRy. Therefore, the s and d valence band complex is spread out and the Fermi level is lowered by the same amount as the s states. We expect to overcome these deficiencies in future investigations by using a ...
Heat transfer and thermal performance analysis of a surface with hollow rectangular fins
Energy Technology Data Exchange (ETDEWEB)
An experimental study was conducted to investigate the heat transfer and friction loss characteristics in a horizontal rectangular channel having attachments of hollow rectangular profile fins over one of its heated surface. The Reynolds number based on the flow averaged inlet velocity and the hydraulic diameter, ranged from 3000 to 32,000. The hollow rectangular profile fins in 10cm height and axb=2cmx4cm dimensions with a thickness of 0.2cm were mounted on a heating surface vertically. Reynolds number, fin arrangement and fin pitch in the flow direction were the experimental parameters. Both in-line and staggered fin arrangements were studied for one-fixed spanwise (S{sub x}/a=3) and four different streamwise (S{sub y}/b=1.5, 1.875, 2.5 and 3.75) distances. Correlation equations for Nu, f and thermal performances were determined for fin configurations and the straight channel case without fins. (author)
2006-02-01
H_2 emission arises outside photodissociation regions in ultra-luminous infrared galaxies
Ultra-luminous infrared galaxies are among the most luminous objects in the local universe and are thought to be powered by intense star formation. It has been shown that in these objects the rotational spectral lines of molecular hydrogen observed at mid-infrared wavelengths are not affected by dust obscuration, leaving unresolved the source of excitation of this emission. Here I report an analysis of archival Spitzer Space Telescope data on ultra-luminous infrared galaxies and demonstrate that star formation regions are buried inside optically thick clouds of gas and dust, so that dust obscuration affects star-formation indicators but not molecular hydrogen. I thereby establish that the emission of H_2 is not co-spatial with the buried starburst activity and originates outside the obscured regions. This is rather surprising in light of the standard view that H_2 emission is directly associated with star-formation activity. Instead, I propose ...
2010-01-01
General order characteristic methods for solving neutron transport problems
Energy Technology Data Exchange (ETDEWEB)
The neutron transport equation in Cartesian geometry possesses straight line characteristics along which the streaming operator can be written as a full differential in terms of the characteristic length. This idea was used by Lathrop to develop the step characteristic method, which he showed to be positive definite but less accurate than conventional Diamond-Difference schemes. Several authors since then have developed new methods utilizing the characteristic curves (including non-Cartesian geometry). A Linear Characteristic Method, based on a more consistent linear representation of the incoming-surface and within-cell angular flux, has been developed and tested in two-dimensional geometry producing highly accurate and computationally efficient results. A similar linear method, with several modifications, was developed for three-dimensional Cartesian geometry, and implemented in ORNL`s production code TORT. In this paper is presented a fully consistent, ...
1992-12-31
Energy Technology Data Exchange (ETDEWEB)
Cooperation for low carbon and energy efficient development is a high priority for France, in line with the United Nations Framework Convention on Climate Change. France contributes to tackling climate change by working with its partners on all continents to implement projects both to mitigate greenhouse gas emissions and to adapt to climate change. Within the framework of the Marrakech Accords, France also encourages the implementation of the Kyoto Protocol Clean Development Mechanism, in particular between French business and non-Annex I countries; this mechanism will facilitate the financing of mitigation projects and contribute to the sustainable development of host countries in the South. At multilateral level, France is a major donor. At a bilateral level, an initial analysis of cooperation projects which are strongly linked to tackling climate change identified public support of 136 millions euros per year, as an average over the past ...
2004-07-01
Fluxnet Synthesis Dataset Collaboration Infrastructure
Energy Technology Data Exchange (ETDEWEB)
The Fluxnet synthesis dataset originally compiled for the La Thuile workshop contained approximately 600 site years. Since the workshop, several additional site years have been added and the dataset now contains over 920 site years from over 240 sites. A data refresh update is expected to increase those numbers in the next few months. The ancillary data describing the sites continues to evolve as well. There are on the order of 120 site contacts and 60proposals have been approved to use thedata. These proposals involve around 120 researchers. The size and complexity of the dataset and collaboration has led to a new approach to providing access to the data and collaboration support and the support team attended the workshop and worked closely with the attendees and the Fluxnet project office to define the requirements for the support infrastructure. As a result of this effort, a new website (http://www.fluxdata.org) has been created to provide access to the Fluxnet synthesis dataset. ...
2008-02-06
Energy Technology Data Exchange (ETDEWEB)
A wider use of renewable energy sources is considered to be the solution to fossil fuel depletion and environmental pollution. This paper discusses various design considerations for line focussing technology to achieve high efficiency and the possibility of generating power in the megawatt range based on solar thermal technologies. The impacts on the environment of conventional thermal power plants is outlined and an estimate made of the cost of pollution abatement measures. A cost benefit analysis is made using a typical 200 megawatt solar thermal plant, 500 km from the load centre, compared with a 220 megawatt coal fired and a similar capacity gas fired power plant, as examples. The results indicated that the energy from the solar thermal power plant is almost twice as expensive compared to conventionally generated electricity. If, however, impacts on the environment and notional cost associated with are considered, electricity from coal ...
1995-12-31
Energy Technology Data Exchange (ETDEWEB)
A wider use of renewable energy sources is considered to be the solution to fossil fuel depletion and environmental pollution. This paper discusses various design considerations for line focussing technology to achieve high efficiency and the possibility of generating power in the megawatt range based on solar thermal technologies. The impacts on the environment of conventional thermal power plants is outlined and an estimate made of the cost of pollution abatement measures. A cost benefit analysis is made using a typical 200 megawatt solar thermal plant, 500 km from the load centre, compared with a 220 megawatt coal fired and a similar capacity gas fired power plant, as examples. The results indicated that the energy from the solar thermal power plant is almost twice as expensive compared to conventionally generated electricity. If, however, impacts on the environment and notional cost associated with are considered, electricity from coal ...
1995-12-31
Electrical wind generation, feasibility study and analysis in Lebanon
International Nuclear Information System (INIS)
Full text.This paper is to investigate the potentials and possibilities of electrical generation via wind turbine. Special attention is directed to the interpretation of wind generation characteristics and parameters found in Lebanon and linking the electrical energy to the Lebanese slectric grid. Although much of the wind energy research is very well established and boomed globally (USA, Europe, India and China), in Lebanon is never used. At a time when climate scientists are increasingly concerned about carbon dioxide emissions from coal and diesel plants, and the nuclear industry is drying, the significance of a major new source os electricity is clear. there are many motives and feasibility criteria for qind power generation in Lebanon. They include the need for increasing the Lebanese electrical capacity, reducing air pollution, alternative energy sources and prices and availability of oil. The work will include literature survey on current wind energy development and application. ...
1999-11-02
British Library Electronic Table of Contents (United Kingdom)
Thymic epithelial cells (TECs) constitute a major component of the thymic stroma which provides a microenvironment critical for developing thymocytes. We have previously demonstrated that doxycycline (Dox), a tetracycline derivative, enhances the proliferation of the mouse thymic epithelial cell line 1 (MTEC1) via MAPK/ERK signal pathway. Herein we provide evidence that Dox also has profound impact on the cytokine production by MTEC1. Specifically, the expression of IL-6 and GM-CSF, both at mRNA and protein levels, was found to be increased in a time- and dose-dependent manner with the addition of Dox. Western blotting analysis revealed that treatment with Dox-induced phosphorylation of the p65 subunit of NF-kB and ERK. Notably, Dox-induced up-regulation of IL-6 and GM-CSF was largely abol...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
It is desired that the data on past ground information are easily picked out and used effectively when construction of power facilities such as power plants is planned. For this purpose, a data base system that is available for survey planning and design business has been developed. This system is divided into subsystems for input, registration, and output, which all can be processed by the personal computers. It also has a retrieval function for maps such as area maps and power facility maps in addition to a retrieval function for characters. As output functions, the system has a function to extract ground information through maps of facilities and their peripheries, an output function for geological profiles and soil test results, and liquefaction analysis and design constant setting support functions. As instances, applications of this system to the thermal power plant location program and to the construction of underground transmission ...
1994-09-05
Development and application of bio-sensor. Production of ammonia sensor
Energy Technology Data Exchange (ETDEWEB)
The objectives of this study are to make a biosensor on a trial basis which can instantaneously measure the nitrogen in wastewater, and to develop a wastewater treatment system which is capable of on-line measurement and controlling. The system provides easier operational control relating to such a high efficient treatment as the removal of nitrogen content in wastewater, serving as a solution to the eutrophication problem. It can be applied also to the analysis of fertilizer components for agriculture. Ammonia oxidizing bacteria were immobilized with cellulose acetate film, which is mounted on a diaphragm type oxygen electrode to make a sensor, and its responsibility was studied. The gradient is slow in high concentration but sharp in low concentration, and it seems possible to use it for the measurement for less than 20 ppm nitrogen concentration. The dependence of the sensor including electrodes and activity of bacteria on temperature is ...
1989-08-01
Cotton plants expressing CYP6AE14 double-stranded RNA show enhanced resistance to bollworms
British Library Electronic Table of Contents (United Kingdom)
RNA interference (RNAi) plays an important role in regulating gene expression in eukaryotes. Previously, we generated Arabidopsis and tobacco plants expressing double-stranded RNA (dsRNA) targeting a cotton bollworm (Helicoverpa armigera) P450 gene, CYP6AE14. Bollworms fed on transgenic dsCYP6AE14 plants showed suppressed CYP6AE14 expression and reduced growth on gossypol-containing diet (Mao et?al., in Nat Biotechnol 25: 1307?1313, 2007). Here we report generation and analysis of dsRNA-expressing cotton (Gossypium hirsutum) plants. Bollworm larvae reared on T2 plants of the ds6-3 line exhibited drastically retarded growth, and the transgenic plants were less damaged by bollworms than the control. Quantitative reverse-transcription polymerase chain reaction (RT-PCR) showed that the CYP6AE1...
2011-01-01
International Nuclear Information System (INIS)
The design boron concentration of the Boron Injection Tank (BIT) in Daya Bay Nuclear Power Station is 21000 #mu#g/g. The BIT should operate under high temperature to avoid boron crystallization, causing higher evaporation, frequent water makeup, higher deposition and pipe blockage to decrease the operability of the safety injection system. The author proposes to decrease the boron concentration in BIT from 21000 #mu#g/g to 7000 #mu#g/g to solve the existing problem. The safety analyses (core DNBR and containment response) are conducted and other impacts are evaluated for the BIT reduction. The analysis results show that the core DNBR meets the safety criterion and the containment pressure is within the design value for the steam line rupture accident after the BIT reduction. The feasibility study report of Daya bay BIT reduction has been approved by NNSA. The site implementation of BIT reduction has been finished successfully
1999-12-01
British Library Electronic Table of Contents (United Kingdom)
Genetic analysis of resistance of plant introduction (PI) 438489B to soybean cyst nematode (SCN) have shown that this PI is highly resistant to many SCN HG types. However, validation of the previously detected quantitative trait loci (QTL) has not been done. In this study, 250 F2:3 progeny of a Magellan (susceptible)??PI 438489B (resistant) cross were used for primary genetic mapping to detect putative QTL for resistance to five SCN HG types. QTL confirmation study was subsequently conducted using F6:7 recombinant inbred lines (RILs) derived from the same cross. Simple sequence repeat (SSR) and single nucleotide polymorphism (SNP) markers were employed for molecular genotyping. Interval mapping (IM), permutation tests, cofactor selection, and composite interval mapping (CIM) were performe...
2011-01-01
Comparison of digital and analogue data acquisition systems for nuclear spectroscopy
International Nuclear Information System (INIS)
In the present investigation the performance of digital data acquisition (DA) and analogue data acquisition (AA) systems are compared in neutron-induced fission experiments. The DA results are practically identical to the AA results in terms of angular-, energy- and mass-resolution, and both compare very well with literature data. However, major advantages were found with the digital techniques. DA allows for a very efficient #alpha#-particle pile-up correction. This is important when considering the accurate measurement of fission-fragment characteristics of highly #alpha#-active actinide isotopes relevant for the safe operation of Generation IV reactors and the successful reduction of long-lived radioactive nuclear waste. In case of a strong #alpha#-emitter, when applying the #alpha#-particle pile-up correction, the peak-to-valley ratio of the energy distribution was significantly improved. In addition, DA offers a very flexible expanded off-line ...
2010-12-21
Energy Technology Data Exchange (ETDEWEB)
Two overlapping cDNA clones encoding human DNA topoisomerase II were identified by two independent methods. In one, a human cDNA library in phage {lambda} was screened by hybridization with a mixed oligonucleotide probe encoding a stretch of seven amino acids found in yeast and Drosophila DNA topoisomerase II; in the other, a different human cDNA library in a {lambda}gt11 expression vector was screened for the expression of antigenic determinants that are recognized by rabbit antibodies specific to human DNA topoisomerase II. The entire coding sequences of the human DNA topoisomerase II gene were determined from these and several additional clones, identified through the use of the cloned human TOP2 gene sequences as probes. Hybridization between the cloned sequences and mRNA and genomic DNA indicates that the human enzyme is encoded by a single-copy gene. The location of the gene was mapped to chromosome 17q21-22 by in situ hybridization of a cloned fragment to metaphase chromosomes ...
1988-10-01
Cloning and expression of a human kidney cDNA for an /alpha//sub 2/-adrenergic receptor subtype
Energy Technology Data Exchange (ETDEWEB)
An /alpha//sub 2/-adrenergic receptor subtype has been cloned from a human kidney cDNA library using the gene for the human platelet /alpha//sub 2/-adrenergic receptor as a probe. The deduced amino acid sequence resembles the human platelet /alpha//sub 2/-adrenergic receptor and is consistent with the structure of other members of he family of guanine nucleotide-binding protein-coupled receptors. The cDNA was expressed in a mammalian cell line (COS-7), and the /alpha//sub 2/-adrenergic ligand (/sup 3/H)rauwolscine was bound. Competition curve analysis with a variety of adrenergic ligands suggests that this cDNA clone represents the /alpha//sub 2/B-adrenergic receptor. The gene for this receptor is on human chromosome 4, whereas the gene for the human platelet /alpha//sub 2/-adrenergic receptor (/alpha//sub 2/A) lies on chromosome 10. This ability to express the receptor in mammalian cells, free of other adrenergic receptor subtypes, should help ...
1988-09-01
Cell behaviour on chemically microstructured surfaces
Energy Technology Data Exchange (ETDEWEB)
Micropatterned surfaces with different chemical topographies were synthesised in order to investigate the influence of surface chemistry and topography on cell behaviour. The microstructured materials were synthesised by photoimmobilising natural Hyaluronan (Hyal) and its sulphated derivative (HyalS), both adequately functionalised with a photorective moiety, on glass substrates. Four different grating patterns (10, 25, 50 and 100 {mu}m) were used to pattern the hyaluronan. The micropatterned samples were analysed by Secondary Ions Mass Spectrometry, Scanning Electron Microscopy (SEM) and Atomic Force Microscopy to investigate the chemistry and the topography of the surfaces. The spectroscopic and microscopic analysis of the microstructured surfaces revealed that the photoimmobilisation process was successful, demonstrating that the photomask patterns were well reproduced on the sample surface. The influence of chemical topographies on the cell behaviour was then ...
2003-03-03
Benefits of the use of radioisotopes in industrial gauging and control
International Nuclear Information System (INIS)
Since the radiometric measuring technique was introduced for industrial measuring and control engineering 15 to 20 years ago, the advantages of this technique have become more and more evident and have led to its world-wide application. In the last 15 to 20 years this method has become the standard one in this field. Its major advantages as compared with conventional methods are: contactless measurement; high reliability and accuracy; no mechanically moving parts; and no maintenance required. Despite higher investment costs the application of this method is paid off within a very short time owing to a higher output and the savings in maintenance costs. Some chemo-technical methods can be realized on a grand scale only when radiometric measuring equipment is used - e.g., urea plants, high-pressure polyethylene production. Especially in moisture measurements of blast-furnace coke are the economical advantages significant. Detailed studies have shown that the system pays off within a few ...
Atrial natriuretic peptide receptor heterogeneity and effects on cyclic GMP accumulation
Energy Technology Data Exchange (ETDEWEB)
The effects of atrial natriuretic peptide (ANP), oxytocin (OT) and vasopressin (AVP) on guanylate cyclase activity and cyclic GMP accumulation were examined, since these hormones appear to be intimately associated with blood pressure and intravascular volume homeostasis. ANP was found to increase cyclic GMP accumulation in ten cell culture systems, which were derived from blood vessels, adrenal cortex, kidney, lung, testes and mammary gland. ANP receptors were characterized in intact cultured cells using {sup 125}I-ANP{sub 8-33}. Specific {sup 125}I-ANP binding was saturable and of high affinity. Scratchard analysis of the binding data for all cell types exhibited a straight line, indicating that these cells possessed a single class of binding sites. Despite the presence of linear Scatchard plots, these studies demonstrated that cultured cells possess two functionally and physically distinct ANP-binding sites. Most of the ANP-binding sites in ...
1988-01-01
An improved soft switched PWM interleaved boost AC-DC converter
International Nuclear Information System (INIS)
In this paper, an improved soft switched two cell interleaved boost AC/DC converter with high power factor is proposed and investigated. A new auxiliary circuit is designed and added to two cell interleaved boost converter to reduce the switching losses. The proposed auxiliary circuit is implemented using only one auxiliary switch and a minimum number of passive components without an important increase in the cost and complexity of the converter. The main advantage of this auxiliary circuit is that it not only provides zero-voltage-transition (ZVT) for the main switches but also provides soft switching for the auxiliary switch and diodes. Though all semiconductor devices operate under soft switching, they do not have any additional voltage and current stresses. The proposed converter operates successfully in soft switching operation mode for a wide range of input voltage level and the load. In addition, it has advantages such as fewer structure complications, lower cost and ease of ...
2011-01-01
API 5L X80M OD 34 inches cold bending
Energy Technology Data Exchange (ETDEWEB)
One of the main factors that require special attention in a pipeline construction is the cold bending process, once depending on the region that the line will be installed the number of bends may achieve 75%, as it was observed in some areas during Campinas-Rio pipeline construction. A study was carried out to evaluate the X80 cold bending operational parameters in order to make viable the use of high strength pipes in the construction of onshore pipelines. For this analysis three pipes of 34 inches x 0.750 inches had been cold bended, the operation was carried out using a hydraulic equipment with punches applications along the pipe, recording the correspondent angles related to the elastic and plastic deformations in order to assess the material spring-back. After the bending process, samples of the weld, extrados and intrados were subjected to mechanical and metallographic tests, as well as performed dimensional inspection of the pipes. It ...
2009-07-01
A space crystal diffraction telescope for the energy range of nuclear transitions
Energy Technology Data Exchange (ETDEWEB)
This paper contains literature from American Power Conference Air Toxics Being Measured Accurately, Controlled Effectively NO{sub x} and SO{sub 2} Emissions Reduced; Surface Condensers Improve Heat Rate; Usable Fuel from Municipal Solid Waste; Cofiring Technology Reduces Gas Turbine Emissions; Trainable, Rugged Microsensor Identifies of Gases; High-Tc Superconductors Fabricated; High-Temperature Superconducting Current Leads; Vitrification of Low-Level Radioactive and Mixed Wastes; Characterization, Demolition, and Disposal of Contaminated Structures; On-Line Plant Diagnostics and Management; Sulfide Ceramic Materials for Improved Batteries; Flywheel Provides Efficient Energy Storage; Battery Systems for Electric Vehicles; Polymer-Electrolyte Fuel Cells for Transportation; Solid-Oxide Fuel Cells for Transportation; Surface Acoustic Wave Sensor Monitors Emissions in Real-Time; Advance Alternative-Fueled Automotive Technologies; Thermal & Mechanical Process; ...
1995-04-01
A multi-marker model for detecting chromosomal segments displaying QTL activity
A statistical method is presented for detecting quantitative trait loci (QTLs), based on the linear model. Unlike methods able to detect a few well separated QTLs and to estimate their effects and positions, this method considers the genome as a whole and enables the detection of chromosomal segments involved in the differences between two homozygous lines, and their backcross, doubled haploid, or F[sub 2] progenies, for a quantitative trait. Genetic markers must be codominant, but missing markers are accepted, provided they are missing independently from the experiment. Asymptotic properties, which are of practical use, are developed. This method does not rely on strong genetic hypotheses, and thus does not permit any precise genetic analysis of the trait under study, but it does assess which regions of the genome are involved, whatever the complexity of the genetic determinism (number, effects and interactions among QTLs). Simultaneous use of ...
1993-08-01
Independent Emission and Absorption Abundances for Planetary Nebulae
Emission-line abundances have been uncertain for more than a decade due to unexplained discrepancies in the relative intensities of the forbidden lines and weak permitted recombination lines in planetary nebulae (PNe) and H II regions. The observed intensities of forbidden and recombination lines originating from the same parent ion differ from their theoretical values by factors of more than an order of magnitude in some of these nebulae. In this study we observe UV resonance line absorption in the central stars of PNe produced by the nebular gas, and from the same ions that emit optical forbidden lines. We then compare the derived absorption column densities with the emission measures determined from ground-based observations of the nebular forbidden lines. We find for our sample of PNe that the collisionally excited forbidden ...
2008-01-01
Seismic stratigraphy and stratigraphic modelling of the South-eastern German Molasse Basin
Although the German Molasse Basin can be regarded as a mature hydrocarbon province, no regional sequence stratigraphic analysis has been carried out so far. We have studied seismic lines and well data from the region between the Isar and Inn rivers (SE Germany) that have been generously supplied by German oil companies (DEE, BEB, Mobil, RWE-DEA and Wintershall). Initial work indicates that five major seismic sequences within three main depositional cycles are developed. The Alpine thrust belt to the south serves as the primary sediment source in the foreland basin. However, sedimentary infill mainly took place parallel to the basin axis. Our analysis suggests that the stratigraphic development of the Molasse Basin was mainly controlled by eustatic sea-level changes which caused the shoreline to shift in the W-E direction. The shifting of the depocenter axis in a N-S direction was controlled by the tectonic evolution of the ...
1995-08-01
Energy Technology Data Exchange (ETDEWEB)
Because of the chaotic nature of the corrosion process and the complexity of the electrochemical noise signals that are generated, there is no generally accepted method of measuring and interpreting these signals that allows the consistent detection and identification of sustained localized pitting (SLP) as compared to general corrosion. We have reexamined electrochemical noise analysis (ENA) of localized corrosion using different hardware, signal collection, and signal processing designs than those used in conventional ENA techniques. The new data acquisition system was designed to identify and monitor the progress of SLP by analyzing the power spectral density (PSD) of the trend of the corrosion current noise level (CNL) and potential noise level (PNL). Each CNL and PNL data point was calculated from the root-mean- square value of the ac components of current and potential fluctuation signals, which were measured simultaneously during a short time period. The PSD ...
1999-01-13
Calibration free laser-induced breakdown spectroscopy of oxide materials
Energy Technology Data Exchange (ETDEWEB)
The quantitative determination of oxide concentration by laser-induced breakdown spectroscopy is relevant in various fields of applications (e.g.: analysis of ores, concrete, slag). Calibration free laser-induced breakdown spectroscopy and the multivariate calibration are among the methods employed for quantitative concentration analysis of complex materials. We measured the intensity of neutral and ionized atomic emission lines of oxide materials by laser-induced breakdown spectroscopy and we modified the calibration free laser-induced breakdown spectroscopy method to increase the accuracy. The concentration of oxides was obtained by using stoichiometric relations. Sample materials were prepared from oxide powder (Fe{sub 2}O{sub 3}, MgO, CaO) by mixing and pressing. The concentration was 9.8-33.3 wt.% Fe{sub 2}O{sub 3}, 7.6-33.3 wt.% MgO and 33.3-81.2 wt.% CaO for different samples. Nd:YAG laser (wavelength 1064 nm, pulse ...
2010-08-15
International Nuclear Information System (INIS)
Total M shell X-ray production cross section for 11 elements with 69 #<=# Z #<=# 92 have been measured using an incident photon energy of 5.96 keV. Measurements have been performed using an "5"5Fe annular source and a Si(Li) detector. Average M shell fluorescence yield at each incident photon energy has been deduced, using the experimental total M X-ray production cross section and theoretical M shell photoionization cross section. Present experimental results are compared with other experimental and theoretical values. Reasonable agreement (to within 0.3-28%) is typically obtained between present and other experimental and theoretical values.
2005-04-01
International Nuclear Information System (INIS)
The effect of swelling of crystalline Ge irradiated at room temperature with 30 keV Ga"+ focused ion beam (FIB) was studied by means of in situ FIB imaging, atomic force microscopy (AFM) and transmission electron microscopy (TEM). The swelling occurred in the surface region of amorphous damage layer which was formed during ion irradiation. The degree of swelling reaches values up to 10 times for an implantation dose of #approx#10"1"7 ions/cm"2. Cross-secitonal TEM examination showed that the swelling is due to formation of a porous layer with a honeycomb structure. (author). 8 refs., 4 figs.
2005-11-20
The Micro-X Imaging Spectrometer Instrument
The Micro-X instrument is a NASA funded, rocket borne X-ray imaging spectrometer planned for launch in January 2011. An array of Transition Edge Sensors (TESs) will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. This will be a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat sink, and will be read out by a SQUID time division multiplexer. X-rays will be focused onto the TES array of 128 pixels on a 600 micron pitch by a conically approximated Wolter optic with an effective area of 200 cm2. The spectrometer will have a field of view of 11.8 arcmin. We describe the design and development progress of the instrument.
2010-01-01
Study of point defect detectors in Si
International Nuclear Information System (INIS)
The importance of point defects in semiconductor and function materials has been studied in detail, but effective means for detecting point defects has not been available for a long time. The end of range defects in Si, produced by 140 keV Ge"+ implantation, were investigated as detectors for measuring the interstitial concentration created by 42 keV B"+ implantation. The concentration of interstitial resulting from the B"+ implantation and the behavior of the interstitial flux under different annealing condition were given. The enhanced diffusion in the boron doped EPI marker, resulting from mobile non-equilibrium interstitials was demonstrated to be transient. Interstitial fluxes arising from processing can be detected by transient enhanced diffusion (TED) of doped marker layers as well
1999-05-01
International Nuclear Information System (INIS)
The decay of "1"0"1Mo to levels in "1"0"1Tc has been studied using the three-parameter (#gamma#-#gamma#-t) coincidence system of HpGe-HpGe detectors. From the coincidence data, the new decay scheme was constructed. The previously reported 104.70, 105.95 and 774.15 keV #gamma# rays were observed, and have been assigned to the decay scheme for the first time. A newly observed 1508.01 keV #gamma# ray has also been assigned to the scheme for the first time. The intensities of #beta#"- and the values of log ft to most levels were calculated
2000-04-01
Structure of Heavy Fe Nuclei at the Point of Transition at N #approx# 37
International Nuclear Information System (INIS)
We have studied energy levels in "6"3Fe populated in the #beta#-decay of "6"3Mn. A new (preliminary) level scheme of "6"3Fe includes 10 excited states connected by 21 #gamma#-rays. The first excited states at 357 and 451 keV have the level half-lives of 110 ps and 780 ps, respectively. Three states, at 357, 451 and 1132 keV, are strongly #beta#-fed with log ft #approx# 5, while there is only a very week #beta#-feeding, if any at all, to the ground state. The new results imply that "6"3Fe departs from a simple shell model structure observed for heavier N = 37 isotones of "6"5Ni and "6"7Zn. (author)
2009-03-01
International Nuclear Information System (INIS)
The L-shell x-ray intensity ratios I(L_#beta#)/I(L_#alpha#) and I(L_#gamma#)/I(L_a_l_p_h_a) for elements with 73 #<=# Z #<=# 83 have been measured at photon incident energies of 17.8, 25.8 and 46.9 keV. The emitted x-rays were measured with a Si(Li) detector system. The results for Re, Pt and Tl are being reported for the first time. A comparison is made of the experimental results with the calculated values obtained by using the theoretical x-ray emission rates, subshell ionisation cross sections, subshell fluorescence yields and Coster-Kronig transition probabilities. The experimental results are in reasonable agreement with the theoretical values. (author).
1988-01-01
International Nuclear Information System (INIS)
Gamma ray spectra in the decay of 185Ta and 185mW have been studied with Ge (Li) detectors. The 185mW isomeric transition at 131.6 keV is shown to be of E3 multipolarity. A level scheme of 185W is proposed with the following energy levels (energies in keV, spin and K quantum numbers in brackets): 0 (3/2- 3/2), 23.5 (1/2- 1/2), 65.9 (5/2- 3/2), 93.5 (3/2- 1/2) (uncertain), 173.9 (7/2- 3/2), 188.1 (5/2- 1/2), 197.5 (11/2+ 11/2) , 243.5 (7/2- 7/2), and 390.8 (9/2- 7/2)
1996-03-04
International Nuclear Information System (INIS)
The MCNPE-BO and MCNP4 Monte Carlo electron-photon codes were used to calculate the dose equivalent per unit fluence at various depths in tissue-equivalent slab phantoms for broad parallel beams of monoenergetic electrons with energies from 50 keV to 10 MeV. The study was carried out in the framework of the activities of a ICRP/ICRU Joint Task Group with the support of EURADOS WG4 (Numerical Dosimetry). Some preliminary results and comparisons as well as a general discussion on the performances of the codes are presented, demonstrating quite a satisfactory agreement among the results obtained using the two codes and those of other authors. (author).
Light emission from hydrogen-copper interaction at grazing incidence
Energy Technology Data Exchange (ETDEWEB)
The optical emission of excited H reflected from clean Cu(110) after impingement of H/sup +/ and H/sub 2//sup +/ in the energy range of 250 eV to 20 keV per nucleon at 70/sup 0/ angle of incidence to the surface normal was measured. For incident 10 keV H/sub 2//sup +/, the highest excited hydrogen state detected was the n=10 level. The Hsub(..cap alpha..) yield was found to be fluence and energy dependent. This effect is attributed either to fast sputtered hydrogen, surface roughness or to an increase with hydrogen concentration in electron states of p-like symmetry near the Fermi level of copper. The Hsub(..cap alpha..) yield per reflected nucleon shows approximately an exponential dependence on both projectile energy per nucleon and scattered particle reciprocal velocity perpendicular to the surface.
1984-03-01
Light emission from hydrogen-copper interaction at grazing incidence
International Nuclear Information System (INIS)
The optical emission of excited H reflected from clean Cu(110) after impingement of H"+ and H_2"+ in the energy range of 250 eV to 20 keV per nucleon at 70"0 angle of incidence to the surface normal was measured. For incident 10 keV H_2"+, the highest excited hydrogen state detected was the n=10 level. The Hsub(#alpha#) yield was found to be fluence and energy dependent. This effect is attributed either to fast sputtered hydrogen, surface roughness or to an increase with hydrogen concentration in electron states of p-like symmetry near the Fermi level of copper. The Hsub(#alpha#) yield per reflected nucleon shows approximately an exponential dependence on both projectile energy per nucleon and scattered particle reciprocal velocity perpendicular to the surface. (orig.).
1983-07-01
Focused Ion Beam Induced Effects on MOS Transistor Parameters
Energy Technology Data Exchange (ETDEWEB)
We report on recent studies of the effects of 50 keV focused ion beam (FIB) exposure on MOS transistors. We demonstrate that the changes in value of transistor parameters (such as threshold voltage, V{sub t}) are essentially the same for exposure to a Ga+ ion beam at 30 and 50 keV under the same exposure conditions. We characterize the effects of FIB exposure on test transistors fabricated in both 0.5 {micro}m and 0.225 {micro}m technologies from two different vendors. We report on the effectiveness of overlying metal layers in screening MOS transistors from FIB-induced damage and examine the importance of ion dose rate and the physical dimensions of the exposed area.
1999-07-28
Energy Technology Data Exchange (ETDEWEB)
The measurements of the K X-ray intensity ratio I(K{sub {beta}})/I(K{sub {alpha}}) for the 17 elements Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Br, Rb, Sr, Y, Zr, Nb and Mo have been done following ionization by 59.5keV {gamma}-rays from a {sup 241}Am point source. Ratios of emission probabilities of Auger electrons and the vacancy transfer coefficients have been extracted in terms of the intensity ratios. It is found that the present results agree well with earlier fitted values and the semi-empirical values.
2006-01-15
Characteristics of wave-particle interaction in a hydrogen plasma
International Nuclear Information System (INIS)
We study the characteristics of cyclotron wave-particle interaction in a typical hydrogen plasma. The numerical calculations of minimum resonant energy Emin, resonant wave frequency ?, and pitch angle diffusion coefficient D?? for interactions between R-mode/L-mode and electrons/protons are presented. It is found that Emin decreases with ? for R-mode/electron, L-mode/proton and L-mode/electron interactions, but increase with ? for R-mode/proton interaction. It is shown that both R-mode and L-mode waves can efficiently scatter energetic (10 keV-100 keV) electrons and protons and cause precipitation loss at L=4, indicating that perhaps wave-particle interaction is a serious candidate for the ring current decay. (authors)
2008-09-01
Atomic scale models of Ion implantation and dopant diffusion in silicon
Energy Technology Data Exchange (ETDEWEB)
We review our recent work on an atomistic approach to the development of predictive process simulation tools. First principles methods, molecular dynamics simulations, and experimental results are used to construct a database of defect and dopant energetics in Si. This is used as input for kinetic Monte Carlo simulations. C and B trapping of the Si self- interstitial is shown to help explain the enormous disparity in its measured diffusivity. Excellent agreement is found between experiments and simulations of transient enhanced diffusion following 20-80 keV B implants into Si, and with those of 50 keV Si implants into complex B-doped structures. Our simulations predict novel behavior of the time evolution of the electrically active B fraction during annealing.
1999-03-01
Outcome of peripherally inserted central venous catheters in surgical and medical neonates
British Library Electronic Table of Contents (United Kingdom)
Background/Purpose: Peripherally inserted central venous catheters (PICCs) are commonly used for neonatal vascular access. The aim of this study was to look at PICC line complication rates and possible predictors of PICC infection in a neonatal intensive care unit. Method: This was a prospective study of 226 neonates who had PICCs on our neonatal intensive care unit between January 2006 and June 2009. Complete data was available on 218 neonates who had 294 PICC lines. Criteria for catheter-related sepsis was positive blood cultures (peripheral/central) and/or a positive catheter tip culture after removal in the presence of a clinical suspicion of line sepsis. Results: Of 218 neonates, 132 (169 lines) were medical, and 86 (125 lines) were surgical. Our PICC line infection rate was 17 infect...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
Abstract Voltage sag caused by faults on an electric power transmission line is one of the most intractable power quality issues for both utility companies and customers. The fault in power system randomly exists along transmission lines due to the combination of many uncertain factors. To predict and assess the annual expected sag frequency (ESF) deriving from the faults along lines, a stochastic based method that employs maximum entropy principle, namely the maximum entropy probability method (MEPM), has been introduced in this paper. Moreover, various types of faults have been considered systematically. With the fault line intervals and the sample moments taken into account, the discrete values of distribution probability of fault locations along the transmission lines have been estimat...
2010-01-01
Economic study of a rural underground transmission system: A site-specific case study: Final report
Energy Technology Data Exchange (ETDEWEB)
This report presents the data and results of a site specific case study comparing costs of an overhead line with an underground circuit traversing the same route. The costs used for the overhead line are actual numbers for a line scheduled to be built by a utility. The underground circuit costs were developed using the same criteria of line rating, contingencies, and location. Often cost comparisons between overhead and underground lines are made using figures taken from studies with widely varying assumptions. This project attempts to provide a comparison by studying the costs of overhead and underground lines following the same route and using the same design assumptions. Caution must be used, however, in extending the results of this study beyond its original intent. It is site-specific and may be representative of only one area of the country. 9 refs., 23 ...
1987-10-01
Electric utilities have been surprised by recent opposition to the construction of very-high-voltage transmission lines, which met with little resistance in the past. Concerns over health and safety factors are associated with the increase in the number of such lines, although their presence has always been an inconvenience and a hazard for those living and working in the immediate vicinity. The new lines present additional hazards due to the continuous flow of small electric currents and the charges that build up in the area of the towers and lines. The lines are also a threat to persons wearing cardiac pacemakers. There is experimental evidence from the Soviet Union and the U.S. that electric and magnetic fields at the frequencies of such power lines can have serious biological effects on growth rates and the functioning of the central nervous system. Full ...
1978-05-01
Continuous human cell lines and method of making same
Energy Technology Data Exchange (ETDEWEB)
Substantially genetically stable continuous human cell lines derived from normal human mammary epithelial cells (HMEC) and processes for making and using the same. In a preferred embodiment, the cell lines are derived by treating normal human mammary epithelial tissue with a chemical carcinogen such as benzo(a)pyrene. The novel cell lines serve as useful substrates for elucidating the potential effects of a number of toxins, carcinogens and mutagens as well as of the addition of exogenous genetic material. The autogenic parent cells from which the cell lines are derived serve as convenient control samples for testing. The cell lines are not neoplastically transformed, although they have acquired several properties which distinguish them from their normal progenitors. 2 tabs.
1985-07-01
A Trajectory Correction based on Multi-Step Lining-up for the CLIC Main Linac
In the CLIC main linac it is very important to minimise the trajectory excursion and consequently the emittance dilution in order to obtain the required luminosity. Several algorithms have been proposed and lately the ballistic method has proved to be very effective. The trajectory method described in this Note retains the main advantages of the latter while adding some interesting features. It is based on the separation of the unknown variables like the quadrupole misalignments, the offset and slope of the injection straight line and the misalignments of the beam position monitors (BPM). This is achieved by referring the trajectory relatively to the injection line and not to the average pre-alignment line and by using two trajectories each corresponding to slightly different quadrupole strengths. A reference straight line is then derived onto which the beam is bent by a kick obtained by moving the ...
1999-01-01
Risks of leukaemia among residents close to high voltage transmission electric lines.
UK PubMed Central (United Kingdom)
OBJECTIVES: To reassess the risk of leukaemia associated with residential exposure near high voltage transmission electric lines of 49 kV and above in view of the recent publications. METHODS: Through...Full Text Available
1997-09-01
UK PubMed Central (United Kingdom)
BackgroundSome epidemiologic studies have suggested an association between electromagnetic field exposure induced by high voltage power lines and childhood leukemia, but null results...Full Text Available
Reproduction in three genetic lines of dairy cattle housed a total confinement system.
UK PubMed Central (United Kingdom)
Dairy cattle of three genetic lines maintained year round in total confinement (either in loose housing or tie stall barn) were monitored for estrous cycle activity and reproductive performance. Only...Full Text Available
1981-10-01
PWM applications for the electric railway traction system fed by the AC/DC dual power line
Energy Technology Data Exchange (ETDEWEB)
The latest electronic circuit technology that can be used for the electric railway traction system fed by an AC/DC dual power line was developed. This system consists of reverse conducting GTO thyristors, microprocessors, and DSP`s. In the AC power supply line section, the line converter is controlled by PWM technology to secure a high power factor and reduce the higher harmonic generation of an input current as far as possible. The line converter and motor converter use reverse conducting GTO thyristors. Since these converters are cooled using a heat pipe cooler, they are reduced in size and weight. The electric grounding point of the main power circuit is set to the negative side of the DC line for AC and DC line sections. Therefore, the AC/DC selector switch was simplified in structure. Moreover, the DC input for the auxiliary power supply can be obtained ...
1996-01-01
Numerical optimization of spherical variable-line-spacing grating X-ray spectrometers
UK PubMed Central (United Kingdom)
Operation of an X-ray spectrometer based on a spherical variable-line-spacing (VLS) grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and...Full Text Available
2011-03-01
Living and Working Around High-Voltage Power Lines.
Energy Technology Data Exchange (ETDEWEB)
This booklet presents safe practices that you should follow if your activities take you near high-voltage transmission lines. It documents information that has generally been available to the public.
1981-08-01
UK PubMed Central (United Kingdom)
A classical velocity centrifugation technique was used to study the in vitro uptake of the new ketolide ABT-773 by human polymorphonuclear neutrophils (PMNs) and a myelomonoblastic cell line, PLB-985,...Full Text Available
2004-04-01
Epigallocatechin gallate inhibits HBV DNA synthesis in a viral replication - inducible cell line
UK PubMed Central (United Kingdom)
AIM: To analyze the antiviral mechanism of Epigallocatechin gallate (EGCG) against hepatitis B virus (HBV) replication.METHODS: In this research, the HBV-replicating cell line HepG2.117 was used...Full Text Available
2011-03-21
Contact Line Pinning by Microfabricated Patterns: Effects of Microscale Topography
UK PubMed Central (United Kingdom)
We study how the microscale topography of a solid surface affects the apparent advancing and receding angles at the contact line of a liquid drop pinned to this surface. Photolithographic methods...Full Text Available
2009-05-05
Cleaning Steam Generators off-Line (Soaking) with Chelants. Final Report.
This report discusses the work done on EPRI program S149-1. In this program the feasibility of cleaning steam generators off line with organic chelants as a means of arresting denting corrosion was investigated. The rationale behind this program is to mak...
1983-01-01
Breakdowns of high-voltage transmission lines due to sea-salt deposits on insulators
Energy Technology Data Exchange (ETDEWEB)
Until 1990, in Tuscany, salt pollution of anti-salt insulators installed on high-tension transmission lines had led to rare breakdowns. On the contrary, in the last months of 1990, in most of Tuscany, following a strong libeccio wind coming from the Tyrrhenian Sea, and due to a long period of drought, salt deposits accumulated on the insulators of the high-voltage transmission lines (380 kV, 220 kV and 132 kV). This phenomenon not only took place in the coastal areas near Livorno, Pisa and Grosseto, but also in areas far away from the sea such as Florence, Prato, Arezzo and Siena. Following this, several high-tension lines, and whole sections of 380 kV electric stations went out of order, damaging the stations' equipment, insulators on the lines, and in particular porcelain insulators. The maintenance operations that were immediately undertaken consisted in washing operations, first focussed on ...
1992-03-01
Breakdowns of high-voltage transmission lines due to sea-salt deposits on insulators
International Nuclear Information System (INIS)
Until 1990, in Tuscany, salt pollution of anti-salt insulators installed on high-tension transmission lines had led to rare breakdowns. On the contrary, in the last months of 1990, in most of Tuscany, following a strong libeccio wind coming from the Tyrrhenian Sea, and due to a long period of drought, salt deposits accumulated on the insulators of the high-voltage transmission lines (380 kV, 220 kV and 132 kV). This phenomenon not only took place in the coastal areas near Livorno, Pisa and Grosseto, but also in areas far away from the sea such as Florence, Prato, Arezzo and Siena. Following this, several high-tension lines, and whole sections of 380 kV electric stations went out of order, damaging the stations' equipment, insulators on the lines, and in particular porcelain insulators. The maintenance operations that were immediately undertaken consisted in washing operations, first focussed on ...
1992-01-01
Energy Technology Data Exchange (ETDEWEB)
This paper presents a method for the optimal design of high voltage transmission lines taking into consideration shielding and backflashover failure rates. The minimization of suitably defined performance indices, which relate the failures caused by lightning in a transmission line to both line insulation level and tower footing resistance, is aimed. Optimum values for both line insulation level and tower footing resistance are calculated. The method is applied on several operating Hellenic transmission lines of 150 and 400kV, respectively, carefully selected among others, due to their high failure rates during lightning thunderstorms. Special attention has been paid on open loop lines, where a possible failure could bring the system out of service causing significant problems. The obtained design parameters, which reduce the failure rates caused by lightning, ...
2006-04-15
A comparison of iterative algorithms and a mixed approach for in-line x-ray phase retrieval
UK PubMed Central (United Kingdom)
Previous studies have shown that iterative in-line x-ray phase retrieval algorithms may have higher precision than direct retrieval algorithms. This communication compares three iterative phase...Full Text Available
2009-08-15
Energy Technology Data Exchange (ETDEWEB)
By means of a global mode analysis of ideal MHD modes for Mercier-unstable equilibria in a planar axis L=2/M=10 heliotron/torsatron system with an inherently large Shafranov shift, the conjecture from local mode analysis for Mercier-unstable equilibria given in [N. Nakajima, Phys. Plasmas 3, 4556 (1996)] has been confirmed and the properties of pressure-driven modes, namely, ballooning modes and interchange modes, inherent to such three-dimensional systems have been clarified. The change of the local magnetic shear due to the Shafranov shift, which is related to toroidicity, reduces the field line bending stabilizing effects on ballooning modes. According to the degree of the reduction of the local magnetic shear by the Shafranov shift, the Mercier-unstable equilibria are categorized into toroidicity-dominant (strong reduction) and helicity-dominant (weak reduction) Mercier-unstable equilibria. Since the local magnetic ...
1998-12-01
Search for anisotropy in the L x-gamma angular correlations following the decay of "2"0"7Bi
International Nuclear Information System (INIS)
An investigation of the Ll x-#gamma# angular correlations following the decay of "2"0"7Bi is done by using a Si(Li) semiconductor counter as L x-ray detector. Coincidence measurements at five different angles were made between the 570-keV #gamma# ray (gated in the movable counter) and the Ll x spectrum (displayed in a multichannel analyzer).
International Nuclear Information System (INIS)
The spectrometric methods and equipment for "2"0"1Pb and "2"0"1Tl activity control in the prepared thallium chloride in industrial production are described. Estimation of thallium-201 activity is carried out in accord with the square of summary photopeak caused by #gamma#-quanta at 167 keV energy. Attenuation is paid to spectrometer calibration. 5 refs.; 2 figs.; 2 tabs.
Radiochemistry of lead-203 for radiolabelling antibody conjugates
International Nuclear Information System (INIS)
Lead-203 [52.1 h, 279 (80.1%) KeV] has been recognized as a potentially useful tracer for tumor specific radiopharmaceuticals due to its favorable nuclear and chemical properties. This paper reports the cyclotron production of lead-203 and the labelling of monoclonal antibody B72.3, conjugated with 2-(p-isothiocyanatobenzyl)DOTA, with lead-203 in 30% yield. In vivo biodistribution and stability studies in mice are being conducted.
1990-06-24
Quantitative phase imaging using hard x-rays
International Nuclear Information System (INIS)
The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.
2009-02-01
Peculiarities of Swift Proton Transmission through Tapered Glass Capillaries
International Nuclear Information System (INIS)
A study of the 150-300 keV proton beam transmission through glass (borosilicate) tapered capillaries with different diameters of the input and output of the capillary was performed. The focusing effect was observed. The areal density of the transmitted beam is enhanced by approximately 20 times. It was shown that changing a taper angle from 0.5 deg to 1.7 deg evidences the increase of the transmission coefficient more than by 300 times keeping the initial energy spectrum of ions. (author)
2011-07-01
Molar extinction coefficients in aqueous solutions of some alkaline earth chlorides
International Nuclear Information System (INIS)
Molar extinction coefficients for the solid solutes in aqueous solutions of some alkaline earth chlorides such as MgCl_2.6H_2O, CaCl_2, SrCl_2.6H_2O and BaCl_2.2H_2O have been determined at 81, 356, 511, 662, 1173 and 1332 keV energies in different concentration using the narrow beam transmission methods. (author)
1999-12-21
Magnetic moments of "1"7"7Ta apd sup(181,182,187)Re states
International Nuclear Information System (INIS)
The magnetic moments of "1"7"7Ta and sup(181,182,187)Re levels decaying via the K-forbidden transitions are measured. The nuclei studied are produced via the "1"7"7W and sup(181,182)Os and "1"8"7W #beta#-decay respectively. The magnetic moments have been measured using the method of the differential #gamma##gamma# angular correlations, perturbed by an external magnetic field. The following magnetic moments and lifetimes are obtained: for the 5/2"-1/2"-[541] "1"8"1Re level with excitation energy of 357 keV #mu#/#mu#sub(n)=2.00+-0.10, Tsub(1/2)=(76+-8)x10sup(-8) s; for the 186.4 keV 5/2"-1/2"-[541] "1"7"7Ta level #mu#/#mu#sub(n)=2.02+-0.13, Tsub(1/2)=(2.78+-0.09)x10sup(-6) s; for the 236 keV 2"- "1"8"2Re level #mu#/#mu#sub(n)=2.12+-0.08; for the 203 keV 9/2"- [514] "1"8"7Re level #mu#/#mu#sub(n)=5.04+-0.09.
1978-03-01
Magnetic moment of the three-quasiparticle state in /sup 177/Ta
Energy Technology Data Exchange (ETDEWEB)
An experimental investigation was made of the ..gamma..-transitions feeding or de-exciting the 1355 keV isomeric state in /sup 177/Ta. The E2/M1 mixing ratios for the 311 keV interband transition from the isomer and for the 271 keV and the 295 keV intraband transitions within the rotational band on the isomer were determined to be delta = 0.29sup(+0.11)sub(-0.06), 0.25sup(+0.05)sub(-0.03) and 0.30sup(+0.06)sub(-0.08), respectively, employing combined measurements of the linear polarization and angular distribution of the ..gamma..-ray with the aid of conversion electron measurements. Spin and parity assignments of the isomer were confirmed to be 21/2/sup -/. The half-life of the isomer was remeasured to be Tsub(1/2) = 5.0 +- 0.2 ..mu..s and the magnetic moment was found to be ..mu.. = 0.080 +- 0.014 ..mu..sub(N). The gsub(K) and gsub(R) factors for the band on the isomer were deduced separately to be ...
1982-06-07
Magnetic moment of the three-quasiparticle state in "1"7"7Ta
International Nuclear Information System (INIS)
An experimental investigation was made of the #gamma#-transitions feeding or de-exciting the 1355 keV isomeric state in "1"7"7Ta. The E2/M1 mixing ratios for the 311 keV interband transition from the isomer and for the 271 keV and the 295 keV intraband transitions within the rotational band on the isomer were determined to be delta = 0.29sup(+0.11)sub(-0.06), 0.25sup(+0.05)sub(-0.03) and 0.30sup(+0.06)sub(-0.08), respectively, employing combined measurements of the linear polarization and angular distribution of the #gamma#-ray with the aid of conversion electron measurements. Spin and parity assignments of the isomer were confirmed to be 21/2"-. The half-life of the isomer was remeasured to be Tsub(1/2) = 5.0 +- 0.2 #mu#s and the magnetic moment was found to be #mu# = 0.080 +- 0.014 #mu#sub(N). The gsub(K) and gsub(R) factors for the band on the isomer were deduced separately to be gsub(K=21/2"-) = ...
Final Report: Planetary Instrument Definition and Design Program (PIDDP) Support Project
Energy Technology Data Exchange (ETDEWEB)
The results of Sandia National Laboratories' participation in the NASA Planetary Definition and Design Program are summarized. Areas reported include the characterization of large area cadmium zinc telluride spectrometers and the application of simulation techniques to the prediction of device performance. Also investigated was the response of mercuric iodide devices in the region from 1 to 100 KeV. A literature study to determine the status or radiation damage measurements in room temperature semiconductor devices is also reported.
1999-03-01
Double-electron-capture cross section for I/sup +/ in a magnesium-vapor target
Energy Technology Data Exchange (ETDEWEB)
Measurements of the double-electron-capture process in which a positive ion of iodine becomes a negative ion in a single collision with a magnesium atom are reported between 20 and 90 keV. The cross section is comparable to that for the rare gases and not as large as might be expected from a two-valence-electron atom. This process is probably insignificant in the production of negative ion beams using a magnesium-vapor target.
1987-06-15
Complete spectroscopy of "8"7","8"8","8"9Sr with (n,#gamma#) and (d,p) reactions?
International Nuclear Information System (INIS)
We conducted (n, #gamma#) and (d, p) reactions leading to "8"7", "8"8", "8"9"Sr in addition to "8"8Sr (d, t) "8"7Sr and 24 keV neutron capture in "8"8Sr. (orig./HSI).
Chemical effects on L_#gamma#_1/L_#beta#_1 x-ray intensity ratio of molybdenum compounds
International Nuclear Information System (INIS)
Chemical effects on the intensity ratio of LX-ray of molybdenum compounds irradiated by 11-keV electrons and by 3-MeV protons were studied using an x-ray crystal spectrometer. It was found that the intensity ratios of L_#gamma#_1/L_#beta#_1 markedly decrease with the increase of ionicity of molybdenum compounds, except for the case of metallic molybdenum. (author).
1987-06-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
