HOAI und Vergabe - erste Erfahrungenmit den Novellen 29. Stahlbauseminar INTAB+ Seminar 2010 Verbundbrucken mit integralen Widerlagern Hamburg Offshore Wind Conference 2010Perfect know-HOW Leichtbausysteme aus Stahl fur Dach und Fassade. Energie- und kosteneffiziente Losungen fur Neu- und Bestandsbau Lubecker Bautag
Three different guidelines define the methods to be used for the quantification of exposures due to the incorporation of radionuclides. The adoption of the Euratom-directive into German law requires the adaptation of these guidelines. With this process, the experiences with the practical application of these regulations must be taken into account. (orig.) [Deutsch] Die Ermittlung der Koerperdosis durch inkorporierte Radionuklide ist in drei Richtlinien des Bundesministeriums fuer Umwelt, Naturschutz und Reaktorsicherheit (BMU) geregelt. Die Umsetzung der Euratom-Direktive in deutsches Recht erfordert die Anpassung dieser Richtlinien. Dabei muessen die bisherigen Erfahrungenmit diesen Richtlinien beruecksichtigt werden. (orig.)
ZusammenfassungDie Botulinumtoxinbehandlung ist eine etablierte Methode in der Behandlung von spasmodischen Dysphonien. Prinzipiell kann eine Behandlung transkutan zervikal, transoral mit einer gebogenen Spritze unter visueller Kontrolle w?hrend der Laryngoskopie sowie mittels flexibler Endoskope bzw. Videoendoskope mit Arbeitskanal erfolgen. Insbesondere die transkutane Injektion unter Larynx-EMG-Kontrolle (LEMG) ist ein verh?ltnism??ig einfaches Verfahren. Aufgrund der visuellen Kontrolle bei transoral oder flexibel transnasal verabreichtem Botulinumtoxin scheint eine bessere Wirksamkeit zu bestehen. Aus verschiedenen Gr?nden kann dieses Verfahren aber nicht bei allen Patienten verwendet werden. Wir berichten ?ber unsere Erfahrungenmit den verschiedenen Techniken und unsere Erw?gungen i...
The amended Radiation Protection Ordinance of 2001 contains regulations on natural radioactive materials, whose recycling or disposal poses practical problems. There is little experience in this field so far. [German] Die novellierte Strahlenschutzverordnung von 2001 befasst sich auch mit natuerlich vorkommenden radioaktiven Stoffen. Bei ihrer Verwertung oder Beseitigung ergeben sich praktische Fragen, die beachtet werden muessen. Erfahrungen auf diesem Gebiet liegen bisher kaum vor. (orig.)
The legal basis to be provided is a licence for decommissioning work, issued for a particular reactor, including activities for recycling of disassembled, radioactive components and materials, subject to radioactivity measurements and exemption from radiological control of materials not exceeding the legally defined maximum level of contamination. (HP) [Deutsch] Es genuegt eine Stillegungsgenehmigung zu einem konkreten Abbauauftrag mit Verwertung radioaktiver Reststoffe nach Freigabe durch Radioaktivitaetsgrenzwertsfestsetzung. (HP)
Zusammenfassung Der vom Bundesamt f?r Sicherheit in der Informationstechnik (BSI) entwickelte Ansatz des IT-Grundschutzes war bereits Gegenstand von Beitr?gen in der DuD. Inzwischen hat das ?Grundschutzhandbuch? Eingang in die internationale Standard-Familie ISO 2700x gefunden. Der Autor berichtet ?ber die Erfahrungenmit den ersten durchgef?hrten Zertifizierungen nach dem neuen ISO-Standard auf der Basis von IT-Grundschutz.
Clear effects of the Act on Power Generation from Renewable Energy Sources (EEWaermeG) on the market cannot be recognized both for the depth geothermal energy and ground source geothermal energy. Due to the concrete design of the law a position that is inferior to others is attained in relation to some other renewable energy sources.
Often measures of protection and restoration of reinforced concrete structures are not taken until damage occurs which affects power plant operation. These failures can be avoided by predictive civil engineering maintenance and repair. The consequent application and implementation of a life-time management system for power plant buildings is being suggested. (orig.)
Zusammenfassung Eine genauere Untersuchung der bekannten Modelle isotropen Materialverhaltens (z.B. von Mises, Tresca, Mohr-Coulomb, Drucker-Prager usw.) zeigt, dass sie selten mit Versuchsergebnissen ?bereinstimmen. Modelle mit inkompressiblen Eigenschaften sch?tzen oft das Materialverhalten bei mehraxialen Zugbelastungen falsch ein. Beim Flie?en unter Druck liefern die Modelle mit kompressiblen Eigenschaften unzul?ssige Werte der Querkontraktionszahl. Erfahrungen zeigen, dass es schwierig ist, mehrdimensionales Materialverhalten bei h?ufig fehlenden Informationen werkstoffgerecht abzubilden. Viele Modelle liefern akzeptable Ergebnisse nur f?r bestimmte Bereiche des Spannungsraumes. Diese Beobachtung hat auf die Idee gef?hrt, ,,bew?hrte?? Modelle miteinander zu verbinden. In diesem Artike...
The report sums up the experience gained with energy efficiency pilot campaigns in Schleswig-Holstein (Schoeth et al., to appear, and Wortman et al., 2000, 2001). The information is to help other actors in this field to develop and optimize their own campaigns. [German] Dieser Bericht resuemiert die wesentlichen Erkenntnisse und Erfahrungenmit wirkungsvoller Umweltwerbung auf Basis der ausfuehrlichen Werbewirkungskontrollen zu den Energieeffizienz-Pilotkampagnen in Schleswig-Holstein (vgl. ausfuehrlicher Schoetz et al., im Druck sowie Wortmann et al., 2000, 2001). Die abschliessenden Abschnitte 'Empfehlungen' und 'Ausblick' kennzeichnen den aktuellen Stand des Wissens und sollen anderen Akteuren mit gleicher oder aehnlicher Zielsetzung Hilfestellung und Anregung fuer die optimierte eigene Planung von Kampagnen geben. (orig.)
Elektrochemische Potentialmessungen (auch Potentialfeldmessungen) haben sich seit Jahren bewahrt, Bereiche mit aktiver chloridinduzierter Korrosion an tausalzexponierten Bauwerken, wie z. B. Bruckentafeln sowie Zwischendecks und Bodenplatten von Parkhausern und Tiefgaragen nachzuweisen. Bereits 1990 erschien die erste Fassung des Merkblatts B3 der DGZfP. Das DAfStb Heft 422 (1991) - Prufung von Beton Empfehlungen und Hinweise zu DIN 1048 - enthielt die Potentialfeldmessung bzw. das Merkblatt B3 im Anhang. In Deutschland liegen somit zwei Jahrzehnte Erfahrungenmit den entsprechenden Regelwerken und naturlich auch in der praktischen Anwendung vor. In der Praxis zeigte sich jedoch auch, dass die Anwendung verbessert werden muss. Die Potentialmessung wurde vielfach sogar falsch durchgefuhrt, ...
Problems with the refractory liners of incinerator combustion chambers have accompanied incinerators from the very beginning. They increased during the past decade, owing to higher combustion temperatures required by law (17. BImSchV), the higher calorific values of the waste to be combusted, and the higher or changed pollutant concentrations in the waste materials. This caused the providers and the materials and the producers of incinerators to develop new refractory products and new design concepts, with a great variety of processes and cost levels. [German] Seit Beginn der Abfallverbrennung, insbesondere aber mit zunehmender Tendenz in den vergangenen 10 Jahren, wird ueber Probleme mit der Feuerfestauskleidung in den Brennkammern von Abfallverbrennungsanlagen geklagt. Als Gruende fuer die zunehmenden Korrosionsprobleme werden die hoeheren gesetzlich geforderten Verbrennungstemperaturen (17. BImSchV), die hoeheren Heizwerte der verbrannten ...
In 1991/1992, VEAG decided to convert its 500 MW plants at Jaenschwalde and Boxberg to the latest state of technology. This even included the discharge of the cleaned flue gas through the existing cooling towers. The site of the flue gas desulphurization plant and also the existing cooling tower shells required routeing of the clean gas lines similar to the routes in the existing plants of RWE. The positive experience accrued with the pipework material `glass-fibre reinforced vinyl ester resin` has also led to the selection of this material here. The universally positive experience gained from existing clean gas lines via cooling towers by very different power station operators induced VEAG and its partners also to equip new construction operations in the new Federal states with this technology. (orig.) [Deutsch] In den Jahren 1991/1992 entschloss sich die VEAG, ihre 500-MW-Anlagen Jaenschwalde und Boxberg auf den neuesten Stand der Technik umzuruesten. Hierzu gehoerte auch die ...
The conference reviewed the state of the art of stationary fuel cell systems, concepts, and the next steps to be taken. Fuel cell systems of several hundred kW have been designed and constructed already. Systems for domestic power supply are in the range of several kW. [German] Die in den letzten zehn Jahren gewonnenen Erfahrungenmit den ersten Pilotanlagen sind eine wichtige und unentbehrliche Hilfe den Weg in den Markt fuer die Brennstoffzelle zu ebnen. Der vorliegende Tagungsband soll diese Erfahrungen fuer die stationaer eingesetzten Brennstoffzellen zusammenfassen und ein aktuelles Bild ueber die daraus gewonnenen Konzepte und Vorstellungen fuer die naechsten Schritte aufzeigen. Bei Energieversorgern sind hier Leistungsgroessen von bis zu mehreren 100 kW eingesetzt worden. Der Leistungsbereich, der fuer die Aufgaben der Hausenergieversorgung typisch ist, befindet sich demgegenueber im Bereich einiger kW. (orig.)
The pilot project of the conversion of the green forage drying plant Lengenfeld to biomass firing could not be realized without problems. But the experience until now shows that it is in principle possible. The farmers involved are devoted to the project. For them the cultivation of biomass is an alternative to the abandonment of fields. The present low oil price sets limits to the positive income effect. The aim is an increase of the biomass share in heating energy supply to about 80%. (orig.) [Deutsch] Die Umstellung der Gruenfuttertrocknung Lengenfeld auf Biomassefeuerung ist als Pilotprojekt nicht ohne Probleme moeglich gewesen. Die bisherigen Erfahrungen zeigen jedoch die grundsaetzliche Praktikabilitaet. Die beteiligten Landwirte sind engagiert bei der Sache und schaetzen die Produktionsmoeglichkeit als Alternative zur Flaechenstillegung. Der derzeit niedrige Oelpreis setzt der positiven Einkommenswirkung jedoch enge Grenzen. Eine Erhoehung des ...
The programme 'Solarthermie 2000' aimed at the testing and optimization of active solar systems, especially for service water heating. Sub-programme 2 was to provide the technical fundamentals and achieve a certain degree of standardization in order to make the technology economically competitive. This necessitated long-term monitoring of a representative number of systems. [German] Im Rahmen des Foerder- und Demonstrationsprogramms Solarthermie 2000, Teilprogramm 2 erfolgt durch die Foerderung von bis zu 100 solarthermischer Anlagen mit Schwerpunkt in den neuen Bundeslaendern eine umfassende Erprobung und Optimierung von Systemen zur aktiven thermischen Sonnenenergienutzung vorwiegend zur Brauchwassererwaermung. Mit dem Teilprogramm 2 sollen die technischen Voraussetzungen fuer einen kuenftigen wirksamen Beitrag der Solarthermie zur Energieversorgung geschaffen und durch Systemstandardisierung die wirtschaftliche ...
On the 28{sup th} of May in 1998, the regulation of the ''Application of roof bolt support in coal mines'' came into force. Afterwards, the new roof bolt permission guidelines have been worked out by the Landesoberbergamt (Inspectorate of mines) in co-operation with the Deutsche Montan Technologie GmbH, with the Deutsche Steinkohle AG and with bolt manufacturers. These guidelines have been put into force on the 31{sup st} of August in 2000. Topics of this paper are the new regulation and first experiences. (orig.) [German] Nach der Erarbeitung der ''Richtlinien ueber die Verwendung von Ankerausbau im Steinkohlenbergbau (Anker-Richtlinien)'' vom 28. Mai 1998 wurden unverzueglich auch die ''Richtlinien ueber die Genehmigung von Ankerausbau (Ankergenehmigungs-Richtlinien)'' in Angriff genommen. Diese Richtlinien, die das Landesoberbergamt NRW gemeinsam mit ...
In 1986, following comprehensive preliminary studies, a 17 MW battery energy storage plant was set up in the insular power supply system of Berlin (West) for the purpose of frequency and output control and provision of immediate reserve capacities. The present paper reports on the initial task, and the dimensioning and construction of this large-scale demonstration as well as the costs entailed in this. It also relates the experiences gained with the operation of the battery energy storage plant in its function as a fast-responding control unit and gives an account of its economic efficiency. Recent studies on the economic efficiency of the plant in conditions as they exist in the present interconnected power supply system are presented. Finally the author reports on the experiences gained with individual plant components, i.e., battery, battery periphery, and power converter and quantifies the cost of plant operation, maintenance, and servicing. (orig./HW) [Deutsch] Im Inselnetz von ...
The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.) [Deutsch] Es wurde die klinische Durchfuehrbarkeit interventioneller Techniken an einem kombinierten Durchleuchtungs- und MR-Arbeitsplatz untersucht. Dieses Hybridsystem erwies sich bei einer Vielzahl interventioneller Eingriffe als vorteilhaft. Der 1,5 Tesla-Magnet ist offenen MR-Systemen hinsichtlich Bildqualitaet und Messzeit ueberlegen. (orig.)
The 'KUPOLOPT' joint research project has as its target the economic and ecological optimization of cupola furnaces in foundries. The use of natural gas/oxygen burners during foundry operation is being studied on Fritz Winter Eisengiesserei GmbH and Co. KG's cupola furnace with the objective of enhancing melting rate, reducing emissions and permitting re-utilization of foundry and other particulates. This work is also intended to improve the cupola-furnace process in economic terms, in order to enhance its competitiveness. This article presents the results of the first project phase, which served to investigate the natural gas/oxygen burner as an external supplier of energy. (orig.)
A number of buildings dating from the 1950s and 1960s were retrofitted with thermal insulation in order to cut energy consumption. This took place within the building competition 'Therma' nitrated by the Federal Ministry of Regional Planning, Building and Town Planning in 1974. Result at that time were so encouraging that now, 15 years later the results were checked again with special attention to the long-term performance of the thermal insulation measures. Laboratory tests prove that the building materials are still in good condition and that humidity has not increased with age. Cracks in the surface plaster of the compound insulation systems occurred at different frequencies and intensities and usually caused by thermal tensions. (BWI).
Licensing procedures are of great importance in the entire decision-making and planning process for erection of cogeneration power plants. The paper presented is a condensed version of the ASUE guide published in May 1999 and gives compact and topical information about legal and procedural aspects for orientation of people not yet familiar with the licensing procedures. An initial outline lists and characterises the procedures involved, which then are explained in greater detail, accompanied by flowsheets and diagrams. (orig./CB) [German] Genehmigungsverfahren besitzen im Entscheidungs- und Planungsprozess eine grosse Bedeutung. Um Planern, Bauherren und Behoerden hierzu einen kompakten und aktuellen Ueberblick bieten zu koennen, wurde dieses Referat als Kurzfassung der im Mai 1999 veroeffentlichten ASUE-Broschuere zusammengestellt. Sie bietet vor allem denjenigen eine Hilfestellung, die noch keine Erfahrungenmit den Genehmigungsverfahren ...
Burner nozzles were often redesigned in order to improve flow design and manufacturing quality. Maintenance intervals, however, are not satisfactory for the operators of such plants. There is no definitive answer as to whether upgraded design allows to lengthen these intervals or whether additional measures are required. Gas turbines may break down for a large number of reasons. This article shows that many of the causes of operational failure and damage are preventable. Damage management will be successful if manufacturers, operators and independent institutions work together.(orig.) [German] Es wurden in der Vergangenheit mehrfach Veraenderungen an den Brennerduesen vorgenommen. Dabei wurden Verbesserungen in der stroemungstechnischen Auslegung und der Fertigungsqualitaet erzielt. Die derzeit noch gueltigen Wartungsintervalle sind fuer den Betreiber unbefriedigend. Inwieweit diese Intervalle mit der modifizierten Ausruestung verlaengert werden koennen oder ob ...
The required introduction of on board diagnosis II in the USA from the 94 models onward has led vehicle manufacturers and system suppliers to develop corresponding diagnosis processes at the beginning of the 1990`s. These systems are now in mass production for TLEV and partly for LEV requirements. Based on experience from the wide use of these functions, new knowledge has been obtained, which must be taken into account in the development of future systems. The additionally more severe emission and diagnosis requirements make further minimisation of the overall tolerances on the one hand, and a revision of the existing diagnosis algorithms necessary. In parallel with this, the Law must create the necessary outline conditions, where the requirements for the vehicle manufacturer and system suppliers must also be met. The OBD II development must therefore certainly not be regarded as complete. [Deutsch] Die in den USA ab Modelljahr `94 geforderte Einfuehrung der On Board Diagnose II hat zu ...
Long duration investigations on XLPE-insulated, medium-voltage cable have been intensively carried out by producers, institutes and users for decades. These tests have concentrated on cable ageing especially under the influence of water. About six years ago, a standard test procedure was developed based on comprehensive know-how. This test procedure is now included in DIN VDE 0276-620. In the following text, experience gained during testing and while performing tests in numerous laboratories is reported, and a summary of the test results is given. (orig.) [Deutsch] Langzeituntersuchungen an VPE-isolierten Mittelspannungskabeln, die sich mit der Alterung der Kabel, besonders unter dem Einfluss von Wasser beschaeftigen, wurden seit Jahrzehnten durch Hersteller, Institute und Anwender intensiv betrieben. Basierend auf diesem sehr umfangreichen Know-how wurde vor rd. sechs Jahren ein standardisiertes Pruefverfahren entwickelt, das heute Bestandteil der DIN VDE 0276-620 ...
Early in 1988 RWE decided to overhaul the power station at Goldenberg. This was necessary due to the age of the plant, the obligation to supply heat and process steam and recent amendments of environmental legislation. After analysing demands and needs one developed a plant concept with a 290 t/h and a 400 t/h steam generator. Due to lack of space the decision was made in favour of a circulating atmospheric fluidised bed combustion instead of steam generators with pulverised lignite combustion as these steam generators take up much more space due to the legally required desulphurisation plants for gaseous emissions. Apart from generating steam RWE wishes to gain experience with this combustion technology and test it for suitability and use in large-scale plant. (orig./KO) [Deutsch] Aufgrund des fortgeschrittenen Alters, der aktuellen Umweltschutzgesetzgebung sowie bestehender Versorgungsverpflichtungen fuer Waerme und Prozessdampf wurde Anfang 1988 von der RWE Energie AG in Essen die ...
Initially, the decision of the operator in Dortmund-Derne to select the impact-type separator concept is explained. None of the tenderers for this 52 t/h boiler could supply references for this fluidized bed steam generator concept with staged combustion in a high-expansion fluidized bed. Under the circumstances, the simple configuration of the Steinmueller fluidized bed steam generator, its compact construction, the reduced amount of refractory and the operational behaviour of the boiler resulting therefrom were decisive in the operator`s decision to select this concept. The development schedule shows the individual stages from cold and hot trials in various test rigs and pilot plants to the final design. So far, this fluidized bed steam generator concept has been realized in the plants Derne (52 t/h), commissioned in November 1989, and Brilon (100 t/h), commissioned in November 1990. The discussion on the essential design features points out to the deliberate differences in the two ...
The regenerator of Stirling cycle machines has an relatively unknown potential for thermal shorting, because the thermal flow path within the solid of a randomly stacked wire mesh, which is defined by its 'connectivity', is unknown. Earlier publications have shown two principles of experimental techniques to quantify connectivity. One quantifies connectivity as a function of axial pressure using the electric current analogy, the other measures connectivity via the temperature gradients along a regenerator and a series-connected reference body of known conductivity. Both papers offer preliminary results of reduced usefulness related to the testing method or setup. This contribution describes a new setup and its technique, which results from the practical knowledge and experience of the first two attempts, and aims for an improved determination of connectivity of the original representative Stirling regenerators with and without housing. Please contact the author for ...
The author investigates whether waste fermentation is an economically feasible alternative to composting. Decisions on projects and sites should not be made until the basic problems of feasibility and economic efficiency are solved. [German] In Anbetracht der derzeitigen Situation bei der Restmuellbehandlung, in der die mechanisch-biologische Behandlung als Alternative zu einer rein thermischen Behandlung immer mehr an Bedeutung gewinnt, stellt sich immer haeufiger die Frage, ob die Restmuellvergaerung eine Alternative zur ausschliesslichen Restmuellrotte darstellt. Diese Frage muss zunaechst prinzipiell aus Sicht der technischen Machbarkeit und von der Sinnhaftigkeit, hier vor allem von der Kostenseite her, betrachtet werden. Erst daran anschliessend lassen sich projekt- und standortbezogene Betrachtungen anstellen. Hinsichtlich der technischen Machbarkeit laesst sich im wesentlichen auf den grosstechnischen Erfahrungen der letzten 8 Jahre bei der ...
For the laying of natural gas transport pipelines severe soil protection guidelines are in force in Switzerland. These guidelines influence, above all, the course of the construction in a substantial way. The Federal Office of Energy promulgated these guidelines in May 1993. They have provisional character and shall be reviewed based on the experiences with the in 1994 executed pipeline constructions. The protection of the soil from mechanical-physical loads, specially from soil erosion and compaction, is also a part of the modification of the federal legislation concerning environmental protection which is being dealt with at present by the federal parliament. (orig.) [Deutsch] Fuer die Verlegung von Erdgas-Transportleitungen gelten in der Schweiz strenge Bodenschutzrichtlinien, die vor allem den Bauablauf nachhaltig beeinflussen. Die Richtlinien wurden im Mai 1993 durch das Bundesamt fuer Energiewirtschaft erlassen. Sie haben provisorischen Charkater und sollen aufgrund der ...
Zusammenfassung Im Jahre 1910 f?hrte der schwedische Internist Hans-Christian Jacobaeus den ersten laparoskopischen Eingriff am Menschen in Stockholm durch. Grundlage seiner Pioniertat waren die tierexperimentellen Studien von Georg Kelling (1866?1945) aus Dresden, der im Jahre 1901 die erste Laparoskopie mittels eines Nitze-Zystoskops am Hund durchf?hrte. Jacobaeus ver?ffentlichte 1910 in der M?nchener Medizinischen Wochenschrift seine Erfahrungenmit den ersten 17 Laparoskopien unter dem Titel: ??ber die M?glichkeit die Zystoskopie bei Untersuchungen ser?ser H?hlen anzuwenden?. Hierbei nutzte er die neue Technik insbesondere zu diagnostischen Zwecken bei unklaren abdominellen Beschwerden und Funktionsst?rungen. Er war auch der Erste, der explizit auf die Gefahr der Darmverletzung bei Er?...
Wider coal lines and larger power plant units necessitate measures for increasing the capacity of the mills without driving up power consumption and installation costs. The result of this development is the modern ALSTOM bowl mill. This paper indicates the stages of development which were necessary for this and the experience which could be accumulated through these measures. The paper also describes in detail the areas of flow in the mills, of design of milling equipment, of mill power supply and of grading in this development. (orig.) [Deutsch] Breitere Kohlebaender und groessere Kraftwerkseinheiten zwingen zu Massnahmen, um die Leistung der Muehlen zu vergroessern, ohne jedoch den Kraftbedarf und die Installationskosten in die Hoehe zu treiben. Das Ergebnis dieser Entwicklung ist die moderne ALSTOM-Schuesselmuehle. Der Beitrag zeigt, welche Entwicklungsschritte hierzu erforderlich waren und welche Erfahrungenmit den Massnahmen gesammelt ...
For purposes of assessing the dumpability of wastes, Article 1 - Ordinance on the Environmentally Responsible Landfilling of Household Wastes (AbfAblV) - of the Ordinance on the Environmentally Responsible Landfilling of Household Wastes and Biological Waste Treatment Plants defines classificaton criteria for biologically and mechanically treated wastes destined for landfilling. The practical experiences that have been gathered with these classification criteria and values were evaluated in a questionnaire-based survey. This was done in particular for the purpose of verifying and validating proposals on the methodology of respiration and fermentation tests. A general finding has been that the application and implementation of the regulations of the AbfAblV is fraught with difficulties. This is evident for one thing in the frequency of analyses and for another in the difficulty of complying with the limit values of the classification criteria. The authors are in support of demands that ...
Purpose: Small suspicious breast lesions that are only visible at MR imaging were preoperatively marked with a hook wire under MR-guidance to allow the removal of the lesion with tissue-sparing surgery. Method: In all patients the suspicious lesions were marked preoperatively under MR guidance with a hook wire using a commercially available stereotactic device. Interventions were performed with MR guidance on a 1.0 T and on a 1.5 T system. Results: In 19 patients 22 lesions were localized. One lesion was missed and removed in a second procedure. The mean duration for localization was 66{+-}20 min (range 38-119 min). In two patients two lesions were localized. The mean deviation of the wire tip to the lesion was 2,0{+-}2,6 mm. In this series, 6 of 22 lesions were malignant. The mean diameter of the lesion was 7.6{+-}2.6 mm (range 3-14 mm). Conclusion: Suspicious breast lesions detectable only in MR imaging can be accurately localized with a hook wire preoperatively under MR control to ...
Surface structure analysis, i.e. metallographic analysis of component surfaces with the aid of replicas, is an established method of component monitoring and the only reliable non-destructive method for detecting and analyzing beginning creep damage in the form of creep pores. Creep pore development provides a basis for component condition analysis. It must be noted, however, that the modern martensitic 9-12 % Cr steels - like the established steels 10CrMo9-10 (P22) und X20CrMoV12-1 - have comparatively high creep fracture deformation rates in fatigue tests. This raises the question if these steels can be judged on the basis of data for established steels. The results so far suggest that even with low pore densities (single pores), a higher degree of damage and a shorter time until failure must be assumed. [German] Eine bewaehrte Methode der Bauteilueberwachung stellt die Oberflaechengefuegeuntersuchung, d. h. die metallografische Untersuchung der Bauteiloberflaeche ...
The aim of the study was to establish by means of a measuring programme how much energy for space heating can be saved by the installed hybrid system. Further, experience with the systems was to be gathered under practical use conditions. As user behaviour can influence space heating energy consumption to an extent having several times the effect of the contribution of the hybrid system, a fact that is also reported in literature, it is not sufficient to measure only space heating energy consumption. So, a unit in one of the terraced houses was scrupulously measured. In the three other terraced houses, only space heating energy consumption was measured.- This final report contains not only a description of the concepts of the buildings and hybrid system but also the energy consumptions measured, and detailed analyses of the budgets. (orig./AKF) [Deutsch] Mit Hilfe eines Messprogrammes sollte ermittelt werden, welche Heizwaermeeinsparung durch das installierte ...
Stabilized austenitic steels can suffer intercrystalline stress corrosion cracking under BWR water conditions. This experience of the last three years, which is important for German nuclear power station technology, has resulted from the discovery of cracks, which were detected in pipework made from titanium-stabilized 1.4541 charged with hot reactor water in six boiling water reactors and in core components made from niobium-stabilized 1.4550 of one BWR plant. Remedies to the pipework have been found by applying optimized materials and fabrication procedures and also by improving water chemistry conditions. (orig.) [Deutsch] Stabilisierte austenitische Staehle koennen unter SWR-Reaktorwasser-Bedingungen interkristalline Spannungsrisskorrosion (IKSpRK) erleiden. Diese fuer die deutsche Kernkraftwerkstechnik bedeutsame Erfahrung der letzten drei Jahre ergab sich aus Rissbefunden, die in mit heissem Reaktorwasser beaufschlagten Rohrleitungen aus dem Ti-stabilisierten ...
Purpose: The aim of this study was to test the feasibility of iliac artery stent placement under MR guidance with real-time MR radial scanning in an animal model. Materials and methods: The experiments were performed on three pigs in a 1.5 T scanner. Radial scanning with a gradient echo technique (T{sub R} 8.4 ms, T{sub E} 3.6 ms, flip angle 10 ) was used. A dedicated backprojector performed the reconstruction of the raw data in real-time. The resulting MR-images were displayed on LCD screens beside the magnet. The sliding window reconstruction technique allowed image acquistion at a frame rate of 16 images per second. MR-compatible self-expanding stents with a diameter of 8 mm and a length of 3 cm were placed into the left iliac artery. Their positions were verified by digital subtraction angiography (DSA) and compared to MRI. Results: All stents were successfully placed. Stent positions as monitored by real-time MR were identical to those seen on DSA images. The time needed for exact ...
The aim of this review is to evaluate the role of inflammatory spine disease in patients with chronic back pain. The contribution of imaging modalities for the diagnostic evaluation of back pain is discussed. A systematic literature search based on the classification of seronegative spondyloarthropathies and rheumatoid arthritis was performed. The results of this search and the experiences in a large collective of rheumatological patients are analyzed. The prevalence of rheumatoid arthritis (1-2%) is comparable to that of spondyloarthropathies (1.9%). The etiology of these entities is not fully elucidated. Magnetic resonance imaging is increasingly used for early detection and surveillance of therapy with TNF-{alpha} antagonists. Bone marrow edema, which is only detectable with MRI, represents an early sign of inflammation. Therapy with TNF-{alpha} antagonists is based on clinical and laboratory criteria, and signs of inflammation in MRI. MRI is useful for assessment of the ...
In technical combustors, flow and combustion processes inside the combustion chamber determine the design and also the safety of the plant. A modelling technique was developed at TU Dresden which comprises both numerical simulations and experimental data and thus achieves a high degree of transparency in its visualisation of the processes inside the combustion chambers under investigation. With the experience gained, numerical models of commercial simulation software (FLUENT, CFX) can be validated by measured values, and potential applications of the programs can be investigated. The first stage of experimental modelling consisted in isothermal (cold) modelling in consideration of flow-relevant similarity characteristics. In the reactive, non-isothermal models, the fuel/air ratio and temperature conditions inside the original combustion chamber were modelled as well. In order to obtain detailed data on the combustion conditions at the burner, measurements were made on a separate ...
To evaluate the current situation and implementation of embolization of uterine leiomyomas into the treatment concept in women with symptomatic uterine leiomyomas in Germany. A questionnaire addressing the clinical background of uterine myomas, recommended treatment concepts, preclinical evaluation, technical approach and complications was sent to 164 departments of gynecology and radiology in Germany. 33 radiological departments and 19 gynecological departments submitted a completed questionnaire. Only 7 departments of radiology reported to have own experience with embolization of uterine leiomyomas, while only 2 departments of gynecology considered embolization as an alternative treatment option in patients with symptomatic leiomyomas. 18/33 radiological departments offer this treatment option but get no patient referrals. Agreement was found concerning the indications for treatment, preclinical evaluation by ultrasound and MRI, preferable location of treatable fibroids, technical ...
After 3 years of construction the trial run of the heating power station HKW 2 ended in November 1997 on time. No extraordinary damage occured during construction, assembly or commissioning. The plant has been operating according to schedule since November 1997. A brief inspection carried out in the summer of 1998 in order to assess warranty claims showed no damage to any part except one valve. Experience shows that all aforementioned activities were necessary. The paper reports about success and negative experience. Certification according to DIN EN ISO 9000ff., however, affords to guarantee of high-quality construction. Builders of such plants therefore need to set up their own quality assurance centre and ensure its technical competence. If necessary,additional experts should be called in.Quality assurance costs for HKW 2 came to about 0.5-0.6 percent of total costs. In view of the success and long life of this investment these expenses are more than justified. (orig.) [German] Nach ...
This 7th edition reveals the progress in steam engineering and the great future potential of steam engineering applications. Pollution abatement and design experiences gained during the operation of existing plants, and experiences gained in waste incineration are of environmental relevance. Recent materials developments and knowledge, e.g. as regards pipes and fittings, have been making significant contributions to supercritical-steam efficiency improvements. Emphasis is also placed on automation, control engineering, water chemistry etc., and on regulations, licensing procedures, and the training of the staff of plants. (orig./KOW) [Deutsch] Die nunmehr vorliegende 7. Ausgabe zeigt den Fortschritt und das zukuenftig noch erhebliche Potential dieser Technik auf. Erfahrungenmit den nun schon seit Jahren laufenden Anlagen zur Schadstoffminderung, Konstruktion und Auslegung sowie Betriebserfahrungen zur thermischen Abfallverwertung sind ...
Low energy buildings promise significant energy savings and help climate preservation by cutting down on annual heating requirements to values below 70 kWh per m{sup 2} dwelling space. It is expected that low energy constructions will become the common standard by the year 2000 as a result of the forthcoming energy saving ordinance. For making the introduction and implementation of this standard successful, practical experience will be essential. For this reason, the state government of Hesse has supported respective pilot projects 1987. In 1989 the funding programme `30 low energy buildings in Hesse` has been established. Consecutively - between 1989 and 1993 - 29 buildings were erected. At first, the thermal quality of the crafted building construction including the ventilation systems was checked. Consecutively, energy consumption, indoor and outdoor temperatures were measured over a time span of several years. The experience of the inhabitants was surveyed. The `Institut Wohnen und ...
The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product measurement in the dosimetry activities in medical diagnostic ...
Aim: Treatment of carcinoma of the uterine cervix by remote afterloading brachytherapy has been accompanied with new isotopes having dose rates different from the classical low-dose rate (LDR) radium source. The dose rate conversion factor from LDR to high-dose rate (HDR) found to be around 0.54 in most studies. As regards medium-dose rate (MDR) brachytherapie, the published data are very few and the experience is still short. In this study the experience of Osaka University Hospital with micro-HDR-Selectron and Selectron-MDR, as a preliminary report of the clinical trial, is presented. Results: The 3-year survival and loco-regional control rates for both modalities were nearly equivalent (62% and 67% for HDR and 68% and 74% for MDR)(totally 45 patients). The cumulative rectal and bladder complication rates were the same in both groups (29% at 3 years), with only 1 patient (MDR-group) developed grade 3 rectal and bladder complication. In this study, point A dose rate correction factor ...
To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI scanner (Magnetom Avanto, Siemens Medical Solutions) with a total field of view of 205 cm and free table movement, all ...
In the future even more than in the past, nuclear power will be indispensable in the present industrialized countries and in those still under development. The safe, nonpolluting, and economic supply of energy to mankind in the future includes so many different problems that the technology of the high-temperature reactor at its present level of development, and with the possibilities is offers above and beyond those provided by other, established, technologies, does not have to mark the end of some old line of development, but rather should be seen as the starting point of a development offering promise for the future. It is for this very reason that the extensive, valuable knowledge and experience accumulated in the construction, operation, and decommissioning of the AVR and THTR plants, the development of the HTR module and other variants and, last, but not least, the valuable results of projects such as PNP, NFE, and HHT, must be preserved at the research centers and with former ...
A cooperative effort of the Center for Solar Energy and Hydrogen Research (ZSW) and Phototronics Solartechnik GmbH (PST) aimed at the transfer of highly efficient solar cells developed on a laboratory scale, to large-area thin-film solar modules suitable for production. This work was based on research and development at the Institute for Physical Electronics (IPE) of Stuttgart University and ZSW on one hand, and on the know-how of PST in regard to large-area module fabrication on the other hand. The various thin-film layers of the cells and modules comprize molybdenum as rear contact, copper-indium(gallium)-diselenide (CIGS) as absorber material, the combination of cadmium sulphide (CdS) and ZnO as window layer. To produce these layers on large areas (30x30 cm{sup 2}), equipment was constructed and procedures were developed. Monolithic series connection of cells, used in other thin-film technologies, was studied and optimized by suitable patterning procedures, such as laser-scribing, ...
Boron Neutron Capture Therapy (BNCT) is a promising binary treatment modality for high-grade primary brain tumors (glioblastoma multiforme, GM) and other cancers. BNCT employs a boron-10 containing compound that preferentially accumulates in the cancer cells in the brain. Upon neutron capture by {sup 10}B energetic alpha particles and triton released at the absorption site kill the cancer cell. In order to gain penetration depth in the brain Fairchild proposed, for this purpose, the use of energetic epithermal neutrons at about 10 keV. Phase I/II clinical trials of BNCT for GM are underway at the Brookhaven Medical Research Reactor (BMRR) and at the MIT Reactor, using these nuclear reactors as the source for epithermal neutrons. In light of the limitations of new reactor installations, e.g. cost, safety and licensing, and limited capability for modulating the reactor based neutron beam energy spectra alternative neutron sources are being ...
The total interaction cross sections (#sigma#_t) of some sugars and amino acids and five elements: lithium, carbon, oxygen, aluminium and calcium have been measured for 6.4 keV, 13.95 keV, 14.4 keV, 17.74 keV, 24.14 keV, 30.8 keV, 35 keV, 59.54 keV, 81 keV, 122 keV and 136 keV photons in a narrow beam good geometry set up, by using high resolution detectors such as a Si-PIN diode detector and a high purity germanium detector. The #sigma#_t values have been used in a matrix method to evaluate the effective atomic numbers Z_e_f_f of the samples from their effective atomic cross sections #sigma#_a. The effective atomic cross section of a sample #sigma#_a is the total interaction cross section divided by the total number of atoms of all types in it. Further, a ...
Intensities of {gamma}-transitions emerging from the EC decay of {sup 203}Pb were measured precisely. The obtained relative {gamma}-intensities are 100%(279.2keV), 4.14+-0.08%(401.3keV) and 0.932+-0.022%(680.5keV). The 279.2 and 680.5keV level feeding {beta}-branching ratios were deduced to be 95.3+-0.1 and 4.7+-0.1% respectively. {sup 203}Pb is suggested for calibration purposes. (author).
The properties of the triplet of low-lying states in {sup 101}Mo have been studied through spectroscopy of the {gamma} radation following thermal neutron capture in {sup 100}Mo and {beta}-decay of {sup 101}Nb and through a measurement of the proton angular distributions in the {sup 100}Mo(d, p) reaction with 14 MeV deuteron energy. The half-lives of the 13.5 keV state and the 57.0 keV 5/2{sup +} state have been measured as 226(7) and 133(7) ns, respectively. These values and the quadrupole/dipole mixing ratios of the 13.5 keV and 43.5 keV transitions yield spin and parity 3/2{sup +} for the 13.5 keV level. The E2 components in the 13.5 (3/2{sup +}->1/2{sup +}) and 43.5 keV (5/2{sup +}->3/2{sup +}) transitions are {le} 8x10{sup -4} and 54(9)%, respectively. The possibility of an additional state near to the 57.0 keV level is discussed. ...
The properties of the triplet of low-lying states in "1"0"1Mo have been studied through spectroscopy of the #gamma# radation following thermal neutron capture in "1"0"0Mo and #beta#-decay of "1"0"1Nb and through a measurement of the proton angular distributions in the "1"0"0Mo(d, p) reaction with 14 MeV deuteron energy. The half-lives of the 13.5 keV state and the 57.0 keV 5/2"+ state have been measured as 226(7) and 133(7) ns, respectively. These values and the quadrupole/dipole mixing ratios of the 13.5 keV and 43.5 keV transitions yield spin and parity 3/2"+ for the 13.5 keV level. The E2 components in the 13.5 (3/2"+#->#1/2"+) and 43.5 keV (5/2"+#->#3/2"+) transitions are #<=# 8x10"-"4 and 54(9)%, respectively. The possibility of an additional state near to the 57.0 keV level is discussed. IBFM/PTQM calculations, taking into ...
The contribution attempts a definition of the concepts of ``technical facilities`` and ``facility management``. [Deutsch] Um mit der Ueberschrift zu beginnen: Was ist Gebaeudetechnik? Die Antwort ist nicht ganz einfach. An der TU Berlin gibt es einen Ingenieur-Studiengang mit dieser Bezeichnung. Es hat etwas mit dem Gebaeude, aber nicht viel mit Architektur zu tun, wie manchmal faelschlich angenommen wird. Um solche Missverstaendnisse gar nicht erst aufkommen zu lassen, hat sich die Gruppe des Vereins Deutscher Ingenieure, die sich mit der Gebaeudetechnik beschaeftigt, als `VDI-Gesellschaft Technische Gebaeudeausruestung` bezeichnet. (orig.)
A semi-empirical relation which can be used to determine the total attenuation cross sections of samples containing H, C, N and O in the energy range 145-1332 keV has been derived based on the total attenuation cross sections of several sugars, amino acids and fatty acids. The cross sections have been measured by performing transmission experiments in a narrow beam good geometry set-up by employing a high-resolution hyperpure germanium detector at seven energies of biological importance such as 145.4 keV, 279.2 keV, 514 keV, 661.6 keV, 1115.5 keV, 1173.2 keV and 1332.1 keV. The semi-empirical relation can reproduce the experimental values within 1-2%. The total attenuation cross sections of five elements carbon, aluminium, titanium, copper and zirconium measured in the same experimental set-up at the energies mentioned ...
The differential cross section measurements for /sup 241/Am, /sup 242m/Am and /sup 243/Am are reviewed in the energy range from 0.5 eV to 10 keV. Parameters extracted from resonance analysis, such as the neutron strength function, the average level spacing, the average capture and fission widths, are compared for the various measurements. The average capture and fission cross sections from 100 eV to 10 keV are directly compared. The status of the data set is discussed with suggestions for further measurements. 24 references.
Zusammenfassung Seit Dezember 2009 ist in Deutschland neben einem 10-valenten (PCV10) auch ein 13-valenter Pneumokokkenkonjugatimpfstoff (PCV13) verf?gbar. Ein Wechsel von PCV7 zu PCV13 ist zu jedem Zeitpunkt einer begonnenen Impfserie problemlos m?glich, von PCV7 zu PCV10 nur bei der Boosterimpfung. F?r alle Kinder mit abgeschlossener vollst?ndiger PCV7- oder -10-Impfserie stellt sich die Frage, ob eine zus?tzliche Impfung mit PCV13 sinnvoll ist. Kinder mit erh?htem Risiko f?r Pneumokokkenerkrankungen gem?? STIKO (St?ndige Impfkommission am Robert?Koch-Institut), die mit PCV7, jedoch nicht mit PPV23 geimpft sind, sollten grunds?tzlich mit PCV13 geimpft werden. Zu diesen Risikokindern sind evtl. auch gesunde, aber bereits im fr?hen Alter in Gemeinschaftseinrichtungen betreute Kinder zu rec...
The study aimed to determine the chemical effects on the K and L X-ray intensity ratios and the K and L X-ray production cross sections for gold compounds. The K shell fluorescence yields and L shell average yields were also investigated. The samples were excited by 59.5keV ?-rays from an 241Am annular radioactive source and 123.6keV ?-rays from a 57Co annular radioactive source. K and L X-rays emitted from samples were counted by an Ultra-LEGe detector with a resolution of 0.150keV at 5.9keV. The experimental values were compared with theoretical, the semi-empirical and other experimental values.
... In a HEAO 1 study of active galaxies, principally Seyfert 1s, in the 2, 165 keV energy range, Rothschild et al. ... As discussed by Rothschild et al. ...
Since mid-1995, Audi is the second European producer to offer a direct-injection diesel engine for passenger cars. The 2.0 l engine is installed in the middle-class sedan Rover 620 SDi. (orig.) [Deutsch] Als nach Audi zweiter europaeischer Hersteller bietet Rover seit Mitte dieses Jahres einen Pkw-Dieselmotor mit direkter Einspritzung an. Eingesetzt wird das Aggregat mit 2,0 l Hubraum in der Mittelklasselimousine Rover 620 SDi. (orig.)
The magnetic #beta#-spectrometer of the #pi# #sq root#2 type with 0.07% pulse resolution is used to measure the intensities of interval conversion electrons on L- and M-subshells of 70.45 keV "1"7"7 Ta gamma-transition. The results are analyzed and the values of mixing parameter #sigma#(E2/M1) and penetration parameter #lambda# are obtained.
A discussion is presented of the 750-KeV chopper experience with both proton and negative ion beams and the ability of these systems to tailor the Linac beam to the diverse requirements of its users; normal accelerator injection, neutron therapy beam, and electron cooling experiments. This flexibility plus a cleaner beam pulse, improved thyratron operation, and mechanical modularity are the results of recent improvements. Additional benefits have been increased reliability and ease of service to the 750-KeV chopper. 3 refs.
The gamma-ray spectrum following neutron capture on /sup 87/Sr was measured at 3 neutron energies: E/sub n/ = thermal, 2 keV, and 24 keV. Gamma rays were detected in a three-crystal Ge(Li)-NaI-NaI pair spectrometer. Gamma-ray intensities deduced from these spectra by spectral unfolding are presented.
A radiometric method was elaborated for surface density determinations of the adhesive layer of plasters by radionuclide X-ray fluorescence using the 17.47 keV bremsstrahlung of "1"4"7Pm/Mo. The bremsstrahlung line excites the 8.63 keV characteristic K#alpha# line of Zn contained in the adhesive layer of the plaster as a filling material in the form of ZnO. In homogeneous adhesive layers the Zn content is proportional to surface density. (author).
An experimental evaluation of the Fano factor F in silicon at hard X-ray energies (5.9-136.5 keV) has been performed by means of a low-noise, high charge collection efficiency silicon drift detector with on-chip electronics. A dependence of F from the detector temperature as well as from the energy of the X-ray photons has been found. Assuming a pair creation energy equal to 3.64 eV, at +20 deg. C the F factor was observed to vary from 0.124{+-}0.006 at 5.9 keV up to 0.159{+-}0.002 at 122 keV. At -35 deg. C, the change of F with respect to the photon energy was less remarkable but nevertheless statistically significant, from 0.123{+-}0.002 at 5.9 keV up to 0.134{+-}0.001 at 122 keV. To our knowledge, the present results represent the first experimental evidence of an energy dependence of the Fano factor in silicon at hard X-ray energies.
A technique has been developed for high resolution alpha particle spectroscopy from track length determination in CR-39 plastic. On individual tracks an energy resolution deltaE close to the range straggling limit is obtainable. For 6 MeV alpha-particle deltaE is proportional 35 keV on individual particles and for groups of particles deltaE proportional 20 keV can be achieved using certain data selection criteria. At 100 keV on individual particles deltaE is proportional 20 keV. The analysis requires 1) a knowledge of the track-etch rate (Vsub(T))-range relationship and 2) a theoretical understanding of alpha-particle track structure in CR-39 as a function of particle energy, dip angle and degree of etching. The structure of alpha-particle etched tracks in CR-39 is described and two methods of analysis discussed. Examples are given of the resolution attainable on tracks of alpha-particles as natural ...
Low-energy focused ion beam (FIB) is a useful tool for shallow doping, gas-assisted etching, and other uses to minimize substrate damage in semiconductor device fabrication. The possibility to form a finely FIB of low energy under 1 keV was suggested in the investigations on the retarding mode in electron optical systems. The abilities of the simplest type of retarding mode FIB column are examined here. The optical properties are calculated for the corresponding model and some images are observed with Ga/sup +/ ion beams <0.3 ..mu..m in diameter for beam energies, 10, 5, and 1 keV, using a retarding mode one-lens FIB system. 1-keV and 100-eV Ga/sup +/ FIB was implanted to Ga/As substrate, and the defects are analyzed by deep-level transient spectroscopy. The defect concentration for 100 eV was < (1)/(5) that for 1000 keV.
Low-energy focused ion beam (FIB) is a useful tool for shallow doping, gas-assisted etching, and other uses to minimize substrate damage in semiconductor device fabrication. The possibility to form a finely FIB of low energy under 1 keV was suggested in the investigations on the retarding mode in electron optical systems. The abilities of the simplest type of retarding mode FIB column are examined here. The optical properties are calculated for the corresponding model and some images are observed with Ga"+ ion beams <0.3 #mu#m in diameter for beam energies, 10, 5, and 1 keV, using a retarding mode one-lens FIB system. 1-keV and 100-eV Ga"+ FIB was implanted to Ga/As substrate, and the defects are analyzed by deep-level transient spectroscopy. The defect concentration for 100 eV was < (1)/(5) that for 1000 keV.
This presentation gives an overview of IBM's experience with its approach to usability engineering, User-Centered Design (UCD), which has been introduced nearly one decade ago. It discusses the characteristics of User-Centered Design and the critical factors for successful deployment: - Establishing a culture for usability engineering. - Making User-Centered Design an integral part of the development process. - Multi-disciplinary teams for the design and evaluation of the total user experience. - Building up organizational structures and an infrastructure for methods, tools, communication, and education. - Applying UCD to UCD itself to continuously improve its process and methods. (orig.)
This is the first interdisciplinary approach to urban water and waste water managment. The author presents the knowledge acquired during the project. [German] Die ganzheitliche Betrachtung der Wasserwirtschaft in urbanen Gebieten ist sowohl in der Forschung als auch in der Praxis neu. Zwischen der Bearbeitung eines Forschungsprojektes und eines Ingenieurprojektes gibt es grundsaetzliche Differenzen, trotzdem sind wir der Meinung, dass es bezueglich der interdisziplinaeren Aspekte und der ganzheitlichen Betrachtung der Wasserwirtschaft sowohl in der Forschung als auch in der Praxis aehnliche Probleme gibt. Aus diesem Grunde wird in dieser Arbeit versucht ueber einige Erfahrungen aus dem interdisziplinaeren und ganzheitlichen Forschungsprojekt zu berichten. (orig.)
The following industrial-scale power station processes are compared with natural gas/light fuel oil heating: Conventional steam generation, steam generation with gas turbine upstream, gas turbine process with low-pressure-waste heat boiler and cogeneration. Industrial gas turbines between 10 and 25 MW are compared with one another; typical boilers and industrial turbines are described. CO{sub 2} and NO{sub x} emissions are indicated. The steam turbines used are the efficient and robust turbines used in industry, wherever possible they are built as single-line plant with the gas turbine. (orig.) [Deutsch] Es werden folgende Industriekraftwerksprozesse mit Erdgas-Leichtoelfeuerung verglichen: Konventioneller Dampfprozess, Dampfprozess mit Vorschaltgasturbine, Gasturbinenprozess mit ND-Abhitzekessel und Kombianlage. Die Industriegasturbinen zwischen 10 und 25 MW werden gegenuebergestellt und typische Kessel und ...
Attempt to form the Schottky barrier on mercury indium telluride (MIT) surface by deposition transparent conducting electrode (TCE) and avoid the negative results by non-rectifier contacts nature, we have investigated the oxidation of clean MIT surfaces to form an insulating layer to overcome this disadvantage by metal-insulator-semiconductor (MIS) photodetectors designing. Oxide film is grown on the MIT surface by plasma enhance chemical vapor deposition (PECVD). Previously cleaned MIT wafers were dipped and boiled in solution, which consists of mixture of bromine and an organic solvent in ratio of 1:50. By the way of using these films as intermediate slightly conducting insulator, a fast-response MIT based surface-barrier photodetectors have been developed. Pt films were used as TCE frontal electrode by vacuum magnetron sputtering (VMS). The current-voltage characteristic is ...
35 patients with ankle sprain were examined by MRI and stress radiographs. 13 were operated afterwards, 22 patients underwent a functional conservative therapy and were examined by MRI and stress radiographs and second time after three months. MRI reports were correct in 12 of 13 operated cases. After conservative therapy we did not find any disrupted ankle ligament. MRI showed intact ligaments thickened by scar. (orig./MG) [Deutsch] 35 Patienten mit klinischem Verdacht auf Aussenbandruptur wurden mit der MRT untersucht. 13 Patienten wurden operiert, 22 konzervativ therapiert. Letztere wurden nach drei Monaten erneut mit MRT und gehaltenen Aufnahmen untersucht. Die MRT-Befunde stimmten in 12 von 13 Faellen mit den operativ erhobenen Befunden ueberein. Nach dreimonatiger konzervativer Therapie waren alle 22 Sprunggelenke stabil. Die rupturierten Baender stellten sich verdickt und durchgaengig dar. ...
In the future fossil fuelled power plants are realised/laid down as combined cycle power plants with high current generation efficiencies. The method of pressure fluidized-bed combustion with downstream hot gas cleaning is going to compete with methods combined with a pressure coal gasification or a pressure dust combustion. The advantages of the pressure fluidized bed combustion are the simpler method set-up and consequently lower investment costs. (orig./CD) [Deutsch] Kohlegefeuerte Kraftwerke werden zukuenftig als kombinierte Gas/Dampfturbinen-Kraftwerke mit hohen Stromerzeugungswirkungsgraden ausgefuehrt werden. Das Verfahren der Druckwirbelschichtverbrennung mit nachgeschalteter Heissgasreinigung und Rauchgasturbine wird dabei mit Verfahren mit einer vorgeschalteten Kohledruckvergasung oder mit einer Druckstaubfeuerung konkurrieren. Die Vorteile der ...
We have shown that energy contamination introduced by ion beam deceleration technology that is used to increase the beam currents available for low energy boron implants, can affect fabricated junctions adversely. A 4 keV "1"1B beam is extracted and retarded by a potential of -3.5 keV for 0.5 keV "1"1B implantation, or by a potential of -3.8 keV for 0.2 keV "1"1B implantation. Intentional beam contamination was introduced by turning off the retarding potential to allow the 4 keV "1"1B ions to irradiate Si wafers directly. The percentage of contamination, at levels of 0.1%, 0.2% and 0.3% was introduced. Rapid thermal annealing of all the implanted samples was performed under N_2 ambient at 1050 deg. C for 1 s. The dopant tail profiles themselves are not significant if the contamination levels are low. However, the much higher damage level coming from high energy ...
The absolute cross sections of "2"3Na(p,n)"2"3Mg, "2"7Al(p,n)"2"7Si and "3"0Si(#alpha#,n)"3"3S reactions were measured in the incident energy range of 5.05 to 5.80, 5.80 to 6.25 and 3.975 to 6.235 MeV respectively using a spherically shaped 4#pi# neutron detector. In the energy range 5.80 to 7.80 and 6.235 to 11.30 MeV the absolute cross sections of "2"3Na(p,n)"2"3Mg and "3"0Si-(#alpha#,n)"3"3S reactions were determined by optical model calculations. The cross sections of the inverse reactions "2"3Mg(n,p)"2"3Na and "3"3S(n,#alpha#)"3"0Si were also calculated by the same method for the neutron energy range of 10 keV to 7.50 MeV for each reaction. The cross section of the latter reaction in the neutron energy range of 10 keV to 840 keV was also determined from its inverse reaction "3"0Si(#alpha#,n)"3"3S by the application of the detailed balance theorem. The reactions for which the cross sections were determined are of ...
The decays of Ta/sup 177/ and Lu/sup 177/ to levels in vestigated with beta spectrometers, NaI(Tl) gamma spectrometers, and fast coincidence and angular correlation techniques. Energy levels in Hf/sup 177/ were characterized according to their energy (kev), the Nilsson asymptotic quantum numbers (Nn/sub 2/ LAMBDA ), the total angular momentum and its component along the symmetry axis (I,K), and the parity ( pi ) as follows: 0STA5I4 7/2, 7/2-!; 112.97STA514 9/2, 7/ 2-!; 249.7STA5I4 11/2, 7/1-!; 32l.34STA624 9/2, 9/2+1; 447.9STA624 11/2, 585.8STA642 7/2, 3/2+1; 509.0STA5I2 5/2, 5/1-1; 605.5STA512 7/2, 5/2-!; 746.04STA633 7/2, 7/2+1; 848.2STA 633 9/2, 7/2+1; and 1058.38STA503 7/2, 7/2-!. The levels at 447.9, 488.8, and 585.8 kev are tentative. The spins and parities were uniquely determined by angular correlation and internal conversion data for the levels at 746.0 and 848.2 kev, asof the levels at 0, ...
Rossi X-ray Timing Explorer (RXTE) observations of the bright supernova remnant Cas A have revealed a hard power law component above 10 keV in addition to two thermal components inferred from ASCA measurements of the many line centroids from low-Z elements. The power law can be shown to be consistent with synchrotron emission from radio to hard x-rays by electrons of up to 4 x 10"1"3 eV. Measurement of the 1157 keV line by CGRO from "4"4Sc in the chain of decay of "4"4Ti predicts that the two "4"4Ti lines at 68 and 78 keV should appear at the CGRO intensity. RXTE has placed upper limits on such lines that are marginally consistent with the CGRO measurement. Implications of these results on sites for cosmic ray acceleration and nucleosynthesis are discussed.
The operation of the negative ion based NBI system for JT-60U has been progressed since 1996. Most of the efforts in the operation for increasing beam power and energy have been concentrated to get over the troubles, caused by surge energy at the moment of the accelerator break-down, in the ion sources and high voltage power supplies. The ion source for the N-NBI, so far, has accelerated negative ion beams of 14.3 A at 380 keV with deuterium and 18.5 A at 360 keV with hydrogen against the target of 22 A. The neutral beam power injected into JT-60U has already reached 5.2 MW at 350 keV for 0.7 sec with deuterium. (author)
A 500 keV negative-ion based NBI system is under construction for NB current drive and plasma core heating in high density plasma in JT-60U. Part of the beamline and the high voltage power supply required for a verification test of an ion source was completed in March 1995. After having done a high potential test of the power supply, the negative-ion generation and acceleration tests started in June 1995 aiming at deuterium beams of 500 keV, 22A. In initial experiment, deuterium negative-ion beams of 410 keV, 6.1A (2.5 MW) for 0.2 sec, so far, have been achieved. This is the world highest D{sup {minus}} current and negative ion beam power. The construction of the total system will be completed by the beginning of 1996, and the beam injection will start in March 1996.
The half-value thicknesses, linear and mass attenuation coefficients of biological samples such as bone, muscle, fat and water have been measured at 140, 364 and 662keV ?-ray energies by using the ATOMLABTM-930 medical spectrometer. The ?-rays were obtained from 99mTc, 131I and 137Cs ?-ray point sources. Also theoretical calculations have been performed in order to obtain the half-value thicknesses and, mass and linear attenuation coefficients at photon energies 0.001keV-20MeV for bone, muscle and water samples. The calculated value and the experimental results of this work and the other results in literature are found to be in good agreement.
Neutron capture ..gamma..-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.
Neutron capture #gamma#-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.
The methods introduced for the field of cleaning waste water can be classified under various processes. Chemical oxidation is done with ozone, hydrogen peroxide and ultraviolet irradiation with subsequent biological decomposition. Another method is ultra-filtration with recovery of valuable materials or waste water ponds with algae biomass to decompose ammonium compounds, nitrates and phosphates. (EF) [Deutsch] Die auf dem Gebiet der Abwasserreinigung vorgestellten Methoden kann man in verschiedene Verfahren einordnen. Die chemische Oxidation erfolgt mit Ozon, Wasserstoff-Peroxid, UV Bestrahlung und anschliessenden biologischen Abbau. Eine andere Methode ist die Ultrafiltration mit Rueckgewinnung von Wertstoffen oder Abwasserteiche mit Algenbiomasse zum Abbau von Ammoniumverbindungen, Nitraten und Phosphaten. (EF)
Zusammenfassung Das Konzept der ?quivalenten Spannung (Vergleichsspannung) wird seit langem angewendet und hat sich bew?hrt. Ein wesentlicher Grund daf?r liegt darin, dass es u.?a. bei der Formulierung ph?nomenologischer Werkstoffmodelle weiterhilft. Von Nachteil ist, dass es weder mit physikalischen Prinzipien in Verbindung steht, noch Informationen ?ber die Mikrostruktur des Werkstoffs enth?lt. Trotzdem wurden zahlreiche Hypothesen zur Formulierung von ?quivalenten Spannungen in der Vergangenheit aufgestellt und in der Praxis mit unterschiedlichem Erfolg angewendet. Als Basis f?r die Systematisierung der zahlreichen Modelle hat Yu die Unified Strength Theory (UST) vorgeschlagen. Diese eignet sich, u.?a. inkompressibles inelastisches Materialverhalten sowie kompressible Werkstoffe mit unt...
Fur die Trennung binarer Gemische wird zunehmend das Simulated Moving Bed (SMB)-Verfahren verwendet. Fur einen storungsfreien Betrieb mussen die Volumenstrome sowie die Umschaltzeit exakt eingestellt werden. In diesem Beitrag wird mit Hilfe des Coherence-Konzepts eine Methode aufgezeigt, mit der sich die Stellgroen fur einen dispersionsfreien SMB-Prozess bestimmen lassen. Fur Langmuir- und Anti-Langmuir-Isotherme konnen einfache explizite Gleichungen bei vollstandiger Trennung angegeben werden. Das Grundprinzip dieser Methode lasst sich auch auf andere Isotherme sowie fur die unvollstandige Trennung ubertragen.
as for direct energy conversion in specialized direct electrical energy conversion plants. Figure 1. An energetic (~163KeV) proton and a 11boron nucleus fuse ...
The decay of "1"0"1Mo to levels in "1"0"1Tc has been studied using the three-parameter (#gamma#-#gamma#-t) coincidence system of HpGe-HpGe detectors. According to the coincidence data, the decay scheme was modified. The positions of 221.80, 318.00, 377.90, 452.50, 515.42, 1011.05 and 1759.72 keV transitions have been arranged again, the transition positions of 104.70, 105.95 and 774.15 keV gamma-rays have been assigned for the first time, the positions of 169.00, 590.91, 980.52 and 1431.68 keV transitions have been reconfirmed, the 1508.01 keV gamma-ray was observed simultaneously for the first time and its transition position has been assigned. The #beta#-intensities and the values of log ft of most levels were calculated. (author)
several authors tried to drive codes to construct nuclear level scheme of nuclei using a set of measured gamma -ray transitions and known energy levels, Ritz combination principle proved to be useful in constructing a more complete decay scheme. In this thesis the energy level schemes of some nuclei have been investigated by the measurements of the gamma - ray energies and use of Ritz combination code. The nuclei under investigation are "110m Ag (253 d)"110 Cd and "166m Ho (1200 yr) "166 E r. On the basis of the suggested level at 2249.02 keV by the Ritz code new positions of the two gamma-ray transitions at 677.5 and 706.6 KeV are found in decay scheme of "110m Ag. Also by this code, new position for the 994.84 KeV gamma-ray transition were established to depopulate the level at 1075.2 KeV.
We demonstrate that the excess vacancies induced by a 1 MeV Si implant reduce the excess interstitials generated by a 40 keV Si implant during thermal annealing when these two implants are superimposed in silicon. It is shown that this previously observed reduction is dominated by vacancy annihilation and not by gettering to deeper interstitial-type extended defects. Interstitial supersaturations were measured using B doping superlattices (DSL) grown on a silicon-on-insulator (SOI) substrate. Implanting MeV and keV Si ions into the B DSL/SOI structure eliminated the B transient enhanced diffusion normally associated with the keV implant. The buried SiO{sub 2} layer in the SOI substrate isolates the deep interstitials-type extended defects of the MeV implant, thereby eliminating the possibility that these defects getter the interstitial excess induced by the keV Si implant. {copyright} {ital 1999 ...
We demonstrate that the excess vacancies induced by a 1 MeV Si implant reduce the excess interstitials generated by a 40 keV Si implant during thermal annealing when these two implants are superimposed in silicon. It is shown that this previously observed reduction is dominated by vacancy annihilation and not by gettering to deeper interstitial-type extended defects. Interstitial supersaturations were measured using B doping superlattices (DSL) grown on a silicon-on-insulator (SOI) substrate. Implanting MeV and keV Si ions into the B DSL/SOI structure eliminated the B transient enhanced diffusion normally associated with the keV implant. The buried SiO_2 layer in the SOI substrate isolates the deep interstitials-type extended defects of the MeV implant, thereby eliminating the possibility that these defects getter the interstitial excess induced by the keV Si implant. copyright 1999 American Institute ...
We have developed a novel technique for measurements of low energy (p,alpha) reactions using heavy ion beams and a differentially-pumped windowless gas target. We applied this new approach to study the 183 keV resonance in the 17O(p,alpha)14}N reaction. We report a resonance energy (center-of-mass) of 183.5{+0.1}{-0.4} keV, a resonance strength of 1.70 +/- 0.15 meV, and set an upper limit (95\\% confidence) on the total width of the state of < 0.1 keV. This resonance is important for the 17O(p,alpha)14}N reaction rate, and we find that 18F production is significantly decreased in low mass ONeMg novae but less affected in more energetic novae. We also report the first determination of the stopping power for oxygen ions in hydrogen gas near the peak of the Bragg curve (E=193 keV/u) to be (63+/-1)e-15 eV-cm2.
The essential mechanical and electronic parts of a beam pulsing system are described, which reaches an energy resolution of ..delta..E/E=0.1%-0.4% in the energy range from 100 eV and 10 keV.
A simulated hull monitoring system based on passive #gamma# ray scanning was set-up in K-01 hot-cell, which consists of a simulated hull basket, a collimator system, a 150 cm"3 HPGe detector and an ORTEC-919 multichannel buffer-computer system. Six different kinds of experimental set-up were established to simulate the variations of #gamma# ray source term distribution (partly concentration) and the variations of matrix density (+46.1%). The experimental results show that the biases of peak area is better than -25.3% for "1"3"7Cs 662 keV #gamma# rays and -18.6% for "1"4"4Ce-"1"4"4Pr 2186 keV #gamma# rays. The hardness of pulse height spectrum is demonstrated to show that the peak area ratio of 2186 keV to 662 keV varies from 380 to 72 when the thickness of lead filter varies form 5 mm to 30 mm. Also studied are the design parameters of collimator system.
Nov 14, 2009 ... Ring Current electrons from the Fok Ring Current Model are computed using plasma and magnetic field values from the SWMF magnetosphere ...
Nov 14, 2009 ... Ring Current electrons from the Fok Ring Current Model are computed using plasma and magnetic field values from the SWMF magnetosphere ...
Nov 14, 2009 ... Ring Current electrons from the Fok Ring Current Model are computed using plasma and magnetic field values from the SWMF magnetosphere ...
The annealing behavior of the radiation damage in epitaxial Pd_2Si and NiSi_2 films on Si, due to the implantation of 100 keV Ar ions, is investigated by using the channeling technique with "4He ions. (U.K.).
Two experiments are currently underway to measure the single-particle weak mixing matrix element for the 1064 KeV transition in "2"0"7Pb. One experiment measures the circular polarization of the 1064 KeV gamma ray emitted from an unpolarized source, while the other experiment measures the forward-backward asymmetry of gamma rays emitted from a polarized source. Analysis of the first set of polarized source data yields an upper limit of 46 eV for the single-particle weak mixing matrix element. copyright 1995 American Institute of Physics.
Total M X-ray cross sections for 12 elements in atomic range 70#<=#Z#<=#92 were measured at 5.96 keV Mn K X-ray photon energy. The average M shell fluorescence yields (anti #omega#_M) of these elements have also been observed using the presently measured cross section values and the theoretical M shell photoionisation cross section values. (orig.).
The #gamma#-radiation following thermal neutron capture in "1"0"0Mo has been studied by singles and coincidence measurements. A "1"0"1Mo level scheme has been deduced and is compared with the results of previous (d,p), (n,#gamma#) and "1"0"1Nb decay studies. The existence of the first excited state at 13.51 keV has been confirmed. The present data yield a neutron binding energy of 5398.4 KeV. (Auth.).
The process of inelastic scattering of hot plasma electrons with energies upto 3 keV by a pair of close-lying nuclear levels (..delta../ital E/less than or equal to2keV), one of whichis isomeric, is discussed. The transition cross sections in the nuclei/sup 242/Am, /sup 171/Lu, and /sup 73/Se are calculated. Estimates of the numberof isomeric nuclei de-excited as a result of electron-stimulated processes in aplasma with parameters characteristic of present-day experiments in controlledthermonuclear fusion are given.
Neutral atom beams with energies above 200 keV may be required for various purposes in magnetic fusion devices following TFTR, JET and MFTF-B. These beams can be produced much more efficiently by electron detachment from negative ion beams than by electron capture by positive ions. We have investigated the efficiency with which such neutral atoms can be produced by electron detachment in partially ionized hydrogen plasma neutralizers.
In this work, the chemical transformations induced by 5 keV protons (10{sup 6} ion cm{sup -2}) at the surface of 0.4 {mu}m polyacrylonitrile and polymethacrylonitrile films are analysed by XPS and IRRAS. Spectroscopic changes in both the polymers are globally similar, the most significant feature being a lower relative concentration of nitrogen with respect to carbon closer to the surface. Quantitatively, this change is more marked in the case of polyacrylonitrile which suggests a direct relation with the hydrogen in {alpha} to the nitrile function.
The first equipment installed at KfK-HDB was a system with a thin-film evaporator. This was later replaced by two vapor compression evaporating units with forced circulation, for evaporation of liquid LAW, and a steam-heated natural circulation evaporator, for evaporation of liquid MAW. Nuclear activities of the Karlsruhe Nuclear Research Center phasing out, the liquid radwaste quantities to be treated have been shrinking accordingly, so that the current system is planned to be replaced by a smaller system with a thin-film evaporator. (orig./HP) [Deutsch] Im Laufe der Jahre wurde die Anlage mit Duennschichtverdampfer durch zwei Bruedenkompressionsverdampfer mit Zwangsumwaelzung fuer die Eindampfung leicht aktiver waessriger Abfaelle und einem dampfbeheizten Naturumlaufverdampfer fuer die Eindampfung mittelaktiver waessriger Abfaelle ersetzt. Mittlerweile sinkt der Abwasseranfall seit Jahren stetig aufgrund der sinkenden Aktivitaeten des ...
The authors shortly describe some basic aspects relating to probabilistic reliability calculation and to the derivation of component reliability data. (GL)
Decaborane (B_1_0H_1_4) cluster ions were implanted into n-Si(100) substrates to fabricate shallow p"+/n junctions. Implant energies of 2 keV, 5 keV, and 20 keV, equivalent to implant energies of the monomer boron ion of 174 eV, 435 eV, and 1.74 keV, respectively, were used at dosages of 1 X 10"1"2 /cm"2 and 1 X 10"1"3 /cm"2. The implanted samples were then subjected to activation annealing at 800 .deg. C, 900 .deg. C, and 1000 .deg. C for 10 s. By using secondary ion mass spectrometry (SIMS) depth profiles, we determined that the depth of the shallow junction (D_s) at a dosage of 1 X 10"1"3 /cm"2 was in the range 12 nm - 45 nm after annealing at 1000 .deg. C. D_s and transient enhanced diffusion (TED) were greatly reduced at implant energies lower than 5 keV, but thermal diffusion (TD) smoothly decreased. In particular, TED was suppressed in the p"+/n junction implanted at 2 ...
A prospective study was performed on 50 patients suffering from osteochondritis dissecans of the knee and ankle to define criteria for stability and fixation of osteochondral lesions. Morphological parameters in MRI (size, fragmentation, cartilage, interface) and conventional radiology (separation, fragmentation) were registered and compared with arthroscopical staging. MRI staging based on different types of interfaces was demonstrated on T{sub 1}- and T{sub 2}-weighted images. MRI could correctly predict a Grade 1 lesion in 50%, a Grade 2 lesion in 90%, a Grade 3 lesion on 0%, and a Grade 4 lesion in 79%. Stable lesions were differentiated from unstable lesions in 90%. Radiographic findings corresponded with arthroscopic staging in only 56% of the cases because fibrotic connection may guarantee stability in case of bony separation. (orig./MG) [Deutsch] In einer prospektiven Studie an 50 Patienten mit einer Osteochondrosis dissecans (OD) des Knie- und ...
Based on the first part of this report the molybdenum loadings of the red mud were varied and the activity of the catalytic additives was tested in a batch autoclave with TJP VR. The 30% Molybdenum loading (sample Nr. 6) was found to be optimum. Further testing with two vacuum residues (TJP VR and ARH VR) and sample Nr. 6, indicates the influences of the process parameters for hydrogen pressures of 9-15 MPa, temperatures of 440-475 C and residence times of 0-60 min. Obviously 440 C, 12 MPa and a residence time of 30 min are best conditions for hydrocracking of both vacuum residues with sample Nr. 6. (orig.) [Deutsch] Beruhend auf dem ersten Teil des Berichtes wird der Belegungsgrad der Rotmasse mit Molybdaen variiert und die resultierenden katalytischen Zusaetze werden in einem Autoklaven mit TJR VR getestet. Ein Belegungsgrad mit 30% Molybdaen (Probe 6) scheint optimal zu sein. Mit diesem Zusatz werden ...
56 patients with the clinical diagnosis of sprained ankles were investigated. Evaluation of the anterior (AFTL) and posterior fibulotalar ligament (PFTL) was performed with the foot in dorsiflexion (20 ) and of the fibulo calcanear ligament (FCL) in plantarflexion (45 ). Axial T{sub 1}w-SE and T{sub 2}w-TSE images were obtained. Full-length visualisation of ligmaments in one slice and the extent of injury were evaluated. 12 ankle injuries were confirmed by operation. With MRI full-length visualisation of lateral ankle ligaments was possible in 86%. A partial/complete rupture of the AFTL was noticed in 33/64% and of the FCI in 29/39%, and of the PFTL in 27/5%. Sensitivity/specificity of MRI when compared to surgery was 100/100% for injuries of the AFTL, 64/100% for the FCL, and 33/78% for the PFTL. (orig./MG) [Deutsch] 56 Patienten wurden mit der klinischen Diagnose einer frischen Supinationsverletzung des oberen Sprunggelenkes untersucht. Das Lig. talofibulare ...
In various situations, measurements in prompt gamma neutron activation analysis (PGNAA) are performed to determine the amount of an elemental impurity relative to that of a major constituent of the matrix. An example of this is the measurement of hydrogen concentration in a metallic matrix. In all such cases, a major contributor to the uncertainty in the measurement is the uncertainty in the ratio of the high-purity germanium (HPGe) detector full-energy peak efficiency for the gamma-ray lines of interest (i.e., impurity and matrix gammas). Usually, the ratio is derived from the relative peak efficiency curve, which is determined using isotopic standards that emit multiple gamma ray lines (e.g., "1"5"2Eu) in the energy range <3000 keV, or using prompt gamma radionuclides (e.g., "1"4N, "3"5Cl) in the energy range >3000 keV. In either case, the uncertainty in the ratio of the peak efficiency values derived from such measurements will be on ...
To evaluate the usefulness of radiation therapy alternative to surgery for clinical N0-N1 non-small cell lung cancer (NSCLC). From 1976 through 1989, 116 patients with NSCLC without mediastinal involvement were treated with definitive radiation therapy alone at Gunma University Hospital. All patients were treated with once-daily standard fractionation using 10 MV X-rays. The total dose ranged from 60 Gy to 80 Gy. The actuarial 2- and 5-year survival rates of the entire group were 43% and 20%, respectively with a median survival time of 19 months. The survival of 76 patients with stage T2 tumors was significantly better than that of 28 patients with T3 tumors (mean survival time 21 versus 15.5 months; p<0.05). Sixty-two patients with tumors less than 5 cm in diameter had a 2-year progression rate of 20%, in comparison with 39% of 54 patients with tumors greater than 5 cm. The difference of survivals for these 2 groups was statistically significant. Twelve patients given a total dose ...
The deregulation of the power industry having been implemented at unparalleled pace in Germany, the marketers and utility managers have been faced with the challenge of coping within relatively short time with the whole range of problems involved in restructurisation in the emerging competitive and very dynamic market. The article summarizes the activities for reorientation and positioning in the market, laying the foundation for success in the future. The communication and IT infrastructure is a major aspect to be considered. The authors explain how the German power industry may profit from international experience and results, so as to gain time in pulling up with competitors in the international marketplace. (orig./CB) [German] Die Liberalisierung der deutschen Stromwirtschaft kann im internationalen Vergleich als einzigartig sowohl hinsichtlich ihrer Breite als auch ihrer Geschwindigkeit - volle Marktoeffnung fuer alle Kunden auf einen Schlag - angesehen werden. Die schnelle ...
The liberalisation of the energy markets requires completely new demands to the information processing procedure of energy supply enterprises. These requirements are to be understood as chances for strengthening of the terms of competition. In the following contribution to this subject the actual status of the concept as converted by the Electricity Supply Company of Halle (Saale) including their departments of district heating, gas and electricity supply will be presented. This concept are comprising all experiences as gathered so far as well as intended further actions to be executed. (orig.) [German] Die Liberalisierung der Energiemaerkte stellt fuer Versorgungsunternehmen voellig neue Anforderungen an die Informationsverarbeitung. Diese Anforderungen sind als Chancen zur Staerkung der Wettbewerbsfaehigkeit zu verstehen. Die Verfasser erlaeutern den aktuellen Stand des in der EVH GmbH Halle (Saale) im Querverbund der Sparten Fernwaerme, Gas und Elektrizitaet umgesetzten Konzeptes, ...
The high-speed direct-injection diesel engine for passenger cars has been a resounding success in the marketplace in the last few years. This was due to an intensive development process as a result of which the direct-injection diesel engine for passenger cars is currently setting new standards with regard to performance and fuel consumption in spite of the constant tightening of emission regulations. Of particular importance in this context is exhaust gas recirculation (EGR). This technology permits a considerable reduction in nitrogen oxide emissions, which are especially critical in the case of the direct-injection diesel engine. In addition, continuing development of supercharging technology, in particular the turbocharger with variable turbine geometry, have allowed further improvement of the full-load behaviour and the engine response and a considerable reduction in the fuel consumption of direct-injection diesel engines. This FVV paper deals with the fundamentals of the ...
Purpose: In vitro evaluation of possible deflection and heating of present-day prosthetic heart valves, 12 technical and 5 biological, were investigated using a 1.5 Tesla Siemens Vision system. Deflection was measured at the edge of a 1.5 Tesla superconducting magnet. Each valve was then submerged in a vial of a 1/1 electrolyte solution and temperature was measured before and after imaging with a turbo-spin-echo sequence (TR 5200 ms, TE 138 ms, Flip angle 180 C, acquisition time 10.5 minutes, length of echo train 29). MR imaging was performed with phase encoding parallel and perpendicular to the plane of the valves. Results: None of the investigated prosthetic heart valves was deflected. The maximal observed temperature rise was 0.5 C. During MR investigation of the prostheses, artifacts caused by metallic parts were less evident using a spin-echo sequence than a gradient-echo sequence. Conclusions: Patients with the tested present-day prosthetic heart valves can be safely imaged by ...
Functional imaging of the pharynx used to be the domain of cineradiography, CT and ultrafast CT. The development of modern MRI techniques led to new access to functional disorders of the pharynx. The aim of this study was to implement a new MRI technique to examine oropharyngeal obstructive mechanisms in patients with obstructive sleep apnea (OSA). Sixteen patients suffering from OSA and 6 healthy volunteers were examined on a 1.5 T whole-body imager (`Vision`, Siemens, Erlangen Medical Engineering, Germany) using a circular polarized head coil. Imaging was performed with 2D flash sequences in midsagittal and axial planes. Patients and volunteers were asked to breathe normally through the nose and to simulate snoring and the Mueller maneuver during magnetic resonance imaging (MRI). Prior to MRI, all patients underwent an ear, nose and throat (ENT) examination, functional fiberoptic nasopharyngoscopy and polysomnography. A temporal resolution of 6 images/s and an in-plane resolution of ...
The results of the creep performance studies at temperatures from 700-1000 C with welds of alloy 800 HT, the manual shielded metal arc welds made with Githerm 85 and Grini 209 filler metals, as well as the MIG pulsed arc welds made with the Nicrofer S 206 and Nicrofer S 5520 filler metals, proved to be in very good agreement with the calculated characteristic values published on VdTUeV sheet 434 in comparative assessments based on creep values valid for a service period of 10 000 hours. The MIG pulsed arc weld made with the Nicrofer S 5520 filler metal achieved by far the best results and strength values comparable to those of the base material, whereas the values of the other welds were corresponding to calculated strength values of the base material reduced by 20%. (orig./CB) [Deutsch] Die im Temperaturbereich von 700-1000 C an Alloy 800 HT und den Elektrodenhandschweissverbindungen mit den Schweisszusaetzen Gritherm 85 und Grini 209, sowie den ...
Two spreading experiments were performed at the FARO facility with prototypical core melts of a UO{sub 2}/ZrO{sub 2} weight percentage of 80/20. The objective was to obtain data on the spreading at flow rates of about 2 l/s of more than 100 kg prototypic high temperature oxide melt on a dry and wet stainless steel plate. For the second spreading test a shallow water layer of 10 mm was added on the substrate. Solutions for an isothermal spreading with a constant volume flux boundary condition in a sector with an angle {phi} are used to analyse the FARO L-32S experiment and to identify the source of discrepancies between the code results (THEMA, CORFLOW) and the experimental findings. The observed spreading behaviour of both FARO experiments can only be explained if an initial melt temperature below the liquidus temperature, i.e. about 120 K lower than the temperature measured by the UTS sensors is assumed. (orig.) [German] Zwei Ausbreitungsexperimente mit einer ...
We study the high-energy emission of the Galactic black hole candidate GX 339-4 using INTEGRAL/SPI and simultaneous RXTE/PCA data. By the end of January 2007, when it reached its peak luminosity in hard X-rays, the source was in a bright hard state. The SPI data from this period show a good signal to noise ratio, allowing a detailed study of the spectral energy distribution up to several hundred keV. As a main result, we report on the detection of a variable hard spectral feature (>150 keV) which represents a significant excess with respect to the cutoff power law shape of the spectrum. The SPI data suggest that the intensity of this feature is positively correlated with the 25 - 50 keV luminosity of the source and the associated variability time scale is shorter than 7 hours. The simultaneous PCA data, however, show no significant change in the spectral shape, indicating that the source is not undergoing a canonical ...
We have investigated the characteristics of ion-beam-induced spontaneous etching (IBISE) of GaAs in Cl_2 ambient by using a Ga-focused ion beam (FIB) with an energy ranging from 3 to 15 keV. The etched depth of the irradiated region was more than 20 times greater than that of unirradiated region. When the sputtered depth by FIB irradiation amounted to around 8 A at each ion energy, the etched depth in Cl_2 ambient for 1 hour became saturated. The saturated etched depths were 450, 550, 750 and 800 A at the ion energy of 3, 5, 10 and 15 keV, respectively. The residual damage of the etched surface was also investigated by photoluminescence (PL) measurement. The maximal PL intensity was obtained at around the threshold dose of IBISE and increased with decreasing ion energy. The full recovery of PL intensity was observed at the ion energy of 3 keV after annealing at 400degC. (author).
The reduction of transient enhanced diffusion (TED) with reduced implantation energy has been investigated and quantified. A fixed dose of 1{times}10{sup 14} cm{sup {minus}2} Si{sup +} was implanted at energies ranging from 0.5 to 20 keV into boron doping superlattices and enhanced diffusion of the buried boron marker layers was measured for anneals at 810, 950, and 1050{degree}C. A linearly decreasing dependence of diffusivity enhancement on decreasing Si{sup +} ion range is observed at all temperatures, extrapolating to {approximately}1 for 0 keV. This is consistent with our expectation that at zero implantation energy there would be no excess interstitials from the implantation and hence no TED. Monte Carlo modeling and continuum simulations are used to fit the experimental data. The results are consistent with a surface recombination length for interstitials of {lt}10 nm. The data presented here demonstrate that in the range of annealing ...
The reduction of transient enhanced diffusion (TED) with reduced implantation energy has been investigated and quantified. A fixed dose of 1x10"1"4 cm"-"2 Si"+ was implanted at energies ranging from 0.5 to 20 keV into boron doping superlattices and enhanced diffusion of the buried boron marker layers was measured for anneals at 810, 950, and 1050 degree C. A linearly decreasing dependence of diffusivity enhancement on decreasing Si"+ ion range is observed at all temperatures, extrapolating to #approx#1 for 0 keV. This is consistent with our expectation that at zero implantation energy there would be no excess interstitials from the implantation and hence no TED. Monte Carlo modeling and continuum simulations are used to fit the experimental data. The results are consistent with a surface recombination length for interstitials of <10 nm. The data presented here demonstrate that in the range of annealing temperatures of interest for p-n ...
The formation of porous structures of nanometre size (nanoporous structures) on germanium (Ge) surfaces by focused ion beam (FIB) irradiations was investigated using various FIB conditions such as ion species, irradiation energies, total fluences, fluence rates, and incident angles. FIB-irradiated regions were observed using a scanning electron microscope and an atomic force microscope. It is found that, using a focused Ga ion beam (Ga FIB) at an energy of 100 keV, the irradiated Ge surface swelled up to ion fluence of 2 x 10"1"7 cm"-"2 with nanoporous structures and then was etched for larger fluences. The shape of swollen nanoporous structures depended on the fluence rate and the incident angle of the Ga FIB. However, such porous structures were observed neither for low-energy (15-30 keV) FIB irradiations using Si and Au ions nor for high-energy (200 keV), heavy ion (Au) irradiation. These observations might be helpful in ...
The measurements of the K X-ray intensity ratio I(K{alpha} {sub 2}/K{alpha} {sub 1}), I(K{beta} {sub 1}/K{alpha} {sub 1}) and I(K{beta}/K{alpha}) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a {sup 241}Am and 123.6 keV {gamma}-rays from a {sup 60}Co were used, and following the radioactive decay of {sup 51}Cr, {sup 55}Fe, {sup 67}Ga, {sup 99}Tc, {sup 111}In, {sup 131}I, {sup 133}Ba, {sup 133}Xe, {sup 137}Cs, {sup 201}Tl and {sup 226}Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.
The measurements of the K X-ray intensity ratio I(K#alpha# _2/K#alpha# _1), I(K#beta# _1/K#alpha# _1) and I(K#beta#/K#alpha#) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV #gamma#-rays from a "2"4"1Am and 123.6 keV #gamma#-rays from a "6"0Co were used, and following the radioactive decay of "5"1Cr, "5"5Fe, "6"7Ga, "9"9Tc, "1"1"1In, "1"3"1I, "1"3"3Ba, "1"3"3Xe, "1"3"7Cs, "2"0"1Tl and "2"2"6Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.
Focused ion beam (FIB) processes have been developed for Y--Ba--Cu--O superconductor films. A Y--Cu liquid metal ion source has been fabricated, using a Y_6_7 --Cu_3_3 eutectic alloy as the ion source. As-sputtered Y--Ba--Cu--O film etch rate ratios to GaAs(100) and Si(100) substrates are 0.28 and 1.4 for 130-keV Au"+ FIB ion etching, respectively. Y--Ba--Cu--O submicron patterns have been demonstrated by using FIB lithography and Cl_2 reactive ion beam etching. Moreover, a Y--Ba--Cu--O superconducting line with 4-#mu#m linewidth has been fabricated by annealing an as-sputtered Y--Ba--Cu--O line pattern. T/sub c/ control of Y--Ba--Cu--O film has been achieved by 200-keV Ne"+, using conventional ion implantation and 300 keV Si"+"+ FIB ion implantation.
The peak flux relationship between hard X-rays and microwaves from solar flares is studied using about 400 events simultaneously recorded with the hard X-ray burst spectrometer on the SMM satellite and the Nobeyama 17 GHz radiometer. The data indicate that the hard X-ray and microwave peak fluxes correlate best for X-ray energies of less than about 80 keV for impulsive flares and greater than about 360 keV for extended flares. By postulating that electrons responsible for microwave emission at 17 GHz are those emitting hard X-rays at these photon energies, it is concluded that: (1) in impulsive flares, microwaves at about 20 GHz are emitted mainly by electrons of less than about 200 keV from a layer through which the electrons stream down into the thick-target hard X-ray source; and (2) in extended flares, microwaves are emitted mainly by MeV electrons trapped in a coronal loop or loops. 59 references.
The localized Pt deposition on Si by 30 keV Ga"+ focused ion beam (FIB), 10 keV electron beam (EB) or dual beams (FIB and EB) using precursor gas has been compared by analysis using a 300 keV Be"2"+ microprobe with a beam spot size of 80 nm. The distribution of deposited Pt, Ga from the ion beam itself, and C from the precursor gas was obtained at and nearby the deposited areas by micro-RBS spectra and RBS mapping. All of the beam processed areas showed a uniform Pt distribution at the deposited areas. The amount of Pt atoms increased with the increase in ion or electron dose due to the decomposition of precursor gas. The thickness of Pt layer by EB is considerably less than that by FIB due to the reduced deposition rate. Ga atoms from the center of processed areas partly redeposited at and nearby the FIB processed areas within #approx#3 #mu#m. The Ga incorporation by dual beam processing was reduced compared with that by ...
We examine the accretion properties in a sample of 42 hard (3-60keV) X-ray selected nearby broad-line AGNs. The energy range in the sample is harder than that usually used in the similar previous studies. These AGNs are mainly complied from the RXTE All Sky Survey (XSS), and complemented by the released INTEGRAL AGN catalog. The black hole masses, bolometric luminosities of AGN, and Eddington ratios are derived from their optical spectra in terms of the broad H$\\beta$ emission line. The tight correlation between the hard X-ray (3-20keV) and bolometric/line luminosity is well identified in our sample. Also identified is a strong inverse Baldwin relationship of the H$\\beta$ emission line. In addition, all these hard X-ray AGNs are biased toward luminous objects with high Eddington ratio (mostly between 0.01 to 0.1) and low column density ($<10^{22} \\mathrm{cm^{-2}}$), which is most likely due to the selection effect of the surveys. The hard ...
By retrofitting the existing steam turbine dual purpose power plant with a gas turbine plant and a secondary waste heat boiler the Technische Werke Ludwigshafen AG have considerably improved the energy generation in energetic, economic and ecological terms. The extension of the existing system to a combined cycle process has lead to this positive effect. The erection of a boiler plant during the first two construction phases has fully met the optimistic expectations. (orig.) [Deutsch] Mit der Nachruestung eines vorhandenen Dampfturbinen-HKW um eine Gasturbinenanlage mit nachgeschaltetem Abhitzekessel haben die Technischen Werke Ludwigshafen AG ihre Energieerzeugung entscheidend in energetischer, oekonomischer und oekologischer Sicht optimiert. Insbesondere die Erweiterung des vorhandenen Systems zu einem GuD-Prozess fuehrt zu dieser positiven Bilanz. Die Errichtung der Kesselanlage in den ersten beiden Bauabschnitten hat die optimistischen ...
Modern oscillation- and analysis systems are often mentioned in the context of oscillation diagnosis which implies that this is a method of establishing the causes of the mechanical changes that cause the unwanted oscillation. Experience shows, however, that oscillation monitoring instruments can merely indicate oscillation symptoms at an early point in time. These findings must be interpreted in a machine-specific way and seen in the context of previous developments in order to establish the mechanical root cause of the matter. A 1000 MVA-generator shows that conventional oscillation measuring systems may also serve for diagnostic purposes within certain limits.(orig.) [German] Im Zusammenhang mit modernen Schwingungsmess- und Analysensystemen wird haeufig der Begriff der Schwingungsdiagnose verwandt und inpliziert, damit auch die Ursache von mechanischen Veraenderungen finden zu koennen, welche das beanstandete Schwingungsverhalten hervorruft. In der Praxis zeigt ...
Optische Uhren nutzen die Anregung optischer Ubergange in neutralen Atomen oder Ionen. Deren Ubergangsfrequenz liegt bei etwa 1015 Hz, also funf Groenordnungen oberhalb der Gigahertz-Schwingungen heutiger Atomuhren. Das erlaubt eine bis zu tausendmal prazisere Zeitmessung. Fur die Genauigkeit ist es entscheidend, dass der Uhrenubergang eine schmale Linienbreite besitzt und seine Frequenz nicht verschoben wird. Dazu mussen die Atome oder Ionen moglichst ungestort und genau lokalisiert sein. Deshalb basiert ein Uhrentyp auf einem kalten Ion in einer Paul-Falle, ein anderer Uhrentyp arbeitet mit vielen kalten Neutralatomen in optischen Gittern. Der Metrologie sollen optische Uhren zunachst als sekundare Realisierung der Sekunde dienen. Derzeit ermoglichen sie bereits Frequenzmessungen mit 17 ...
Flow Tex and ABB Energiekabel GmbH have developed a technique which allows the recovery of cables without requiring any trenching works. The new technique was successfully used for the first time for a pilot project in 1995. The authors report on two recent recovery projects (1998) in which an optimised technology was used for recovering a total of 1 500 m system length of 110 kV low-pressure oil-filled cables in Stuttgart and Munich on very different conditions. The authors describe the operational experiences with the cable connections and highlight the background stipulating the removal of the cables. (orig.) [Deutsch] Ein Verfahren zur grabungsfreien Bergung von Kabeln, gemeinsam entwickelt von FlowTex und ABB Energiekabel, wurde erstmals in einem Pilotprojekt 1995 mit Erfolg eingesetzt. Die Verfasser berichten ueber zwei Bergungsprojekte, bei denen 1998 mit der optimierten Technik in Stuttgart und Muenchen insgesamt 1 500 Systemmeter ...
We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.) [Deutsch] Die Befunde von drei Patienten mit intrakranieller Tuberkulose (intrakranielle Miliartuberkulose, Meningitis tuberculosa, Neuritis und Tuberkulome) in der Magnetresonanztomographie (MRT) wurden mit der Computertomographie (CT) verglichen. Sowohl die MRT als auch die CT wurden nativ und nach Kontrastmittelgabe durchgefuehrt. Die MRT zeigte sich im Nachweis von Granulomen insbesondere im Bereich des Hirnstamms ueberlegen. Ebenso wurde ein hoeherer Bildkontrast bei der ...
The described heat transfer model supplies plausible results for the size distribution of active nucleation spots. For boiling states for which a comparison with measured bubble covering density is possible, that is for low boiling pressures and low heat flux densities, the bubble covering densities calculated by model on the basis of heat transfer measurements agree relatively well with the values observed. (orig.) [Deutsch] Das beschriebene Waermeuebergangsmodell liefert plausible Ergebnisse fuer die Groessenverteilung der aktiven Keimstellen. Fuer die Siedezustaende, fuer die ein Vergleich mit gemessenen Blasenbelegungsdichten moeglich ist, d.h. fuer niedrige Siededruecke und kleine Waermestromdichten, stimmen die aufgrund der Waermeuebergangsmessungen mit dem Modell berechneten Blasenbelegungsdichten verhaeltnismaessig gut mit den beobachteten Werten ueberein. (orig.)
The adaption of the Muster-VAwS (model ordinance on the handling of water endangering substances in plants and specialized facilities) in the ordinances of the different German states, means that the legislator has laid down concrete - technical and organizational - requirements concerning the handling of water-endangering substances for all plants. The present example of the systematic stocktaking of all environmentally relevant substances in the context of the operation of the pumped storage plants of Schluchseewerk AG, Freiburg, an the application of the model operating instructions for hydropower plants shall serve to illustrate two important aspects for the implementation of this extensive ordinance. (orig.) [Deutsch] Durch Umsetzung der Muster-VAwS (Muster-Verordnung ueber Anlagen zum Umgang mit wassergefaehrdenden Stoffen und Fachbetriebe) in entsprechende Laenderverordnungen wurden durch den Gesetzgeber konkrete Anforderungen, technisch und organisatorisch, ...
For the calculation of humidifier systems in supply air systems nomographs and appropriate software are not sufficient alone. System design factors must be considered, also. On the basis of a clear definition interpretation examples are described and remarks for the effective installation of steam distribution systems are given. (orig.) [Deutsch] Es ist nicht zu empfehlen, Befeuchterstrecken bzw. Dampfdiffusionsstrecken ausschliesslich ueber Nomogramme oder ueber eine entsprechende Software auszulegen. Zumindest sollte vorher genauestens geprueft werden, welche Parameter in die Berechnung mit einfliessen. Zur exakten Berechnung der Absorptionsstrecken in Zuluftsystemen muessen auch anlagenspezifische Faktoren beruecksichtigt werden. Die Erfahrung hat jedoch gezeigt, dass dem Begriff `Befeuchterstrecke` zu wenig Aufmerksamkeit gewidmet wird. Hierdurch koennen Fehler entstehen, die nur mit relativ hohem finanziellem Aufwand wieder zu korrigieren ...
Pulmonary tumors in children are rare. Nevertheless, there are besides malign primary neoplasms and metastases also some benign tumors that the radiologist should know. The identification of some tumors is difficult, since some of them may mimic pulmonary inflammation. The first diagnostic tool is chest radiography. After that, a CT with contrastmedium should be performed, if possible a multislice-CT (MSCT). Identification of mediastinal structures is best with MRI. (orig.) [German] Tumoren der Lunge sind im Kindesalter selten. Trotzdem finden sich neben den malignen primaeren und sekundaeren Raumforderungen auch im Kindesalter immer wieder benigne Tumoren, die der Radiologe kennen sollte. Eine eindeutige Identifizierung kann schwierig sein, da z. B. entzuendliche Infiltrate vorgetaeuscht werden koennen. Die primaere Untersuchungsmethode ist das konventionelle Thoraxroentgen. Die weitere Diagnostik muss mit der Computertomographie, nach Moeglichkeit ...
Internal combustion engines with mechanically driven superchargers are known for good performance at low engine speeds and fast response times under fluctuating loads. Application engineers can choose between superchargers with and without internal compression - the familiar roots (blower) type or true compressors - for supercharging an internal combustion engine. This article by DaimlerChrysler describes two options for improving the partial load behaviour of mechanically supercharged internal combustion engines with compressors. (orig.) [German] Die Aufladung mit mechanisch angetriebenen Verdraengerladern zeichnet sich durch guten Druckaufbau bei niedrigen Drehzahlen und gute Dynamik bei Lastwechseln aus. Fuer die Applikation am Verbrennungsmotor koennen Maschinen ohne innere Verdichtung - wie die bekannten Roots-Geblaese - oder Maschinen mit innerer Verdichtung - Kompressoren im eigentlichen Sinne - zum Einsatz kommen. In diesem Beitrag von ...
Modernisation of older office buildings commonly includes installation of air conditioning systems as good air quality and thermal comfort will improve the staff`s efficiency at work. However, what about tenants who want their own, individually controlled single-storey air conditioning plang? And what about retrofitting further storeys with single-storey air conditioning? An exemplary solution to this problem was found in Hamburg. (orig.) [Deutsch] Bei der Sanierung aelterer Buero- und Geschaeftshaeuser werden die Raeume immer haeufiger mit Klimaanlagen ausgestattet. Ein Grund fuer den Trend zur Klimatisierung: Gute Luftqualitaet und angenehme Temperaturen erhoehen die Leistungsfaehigkeit des Menschen. Was aber, wenn ein Mieter fuer seine Bueroetage eine eigene, individuell steuerbare Klimaanlage wuenscht? Und was passiert, wenn andere Bueroetagen mit weiteren Klimaanlagen nachgeruestet werden? In Hamburg wurde dieses Problem auf beispielhafte ...
Total M shell X-ray production cross section for 11 elements with 69 #<=# Z #<=# 92 have been measured using an incident photon energy of 5.96 keV. Measurements have been performed using an "5"5Fe annular source and a Si(Li) detector. Average M shell fluorescence yield at each incident photon energy has been deduced, using the experimental total M X-ray production cross section and theoretical M shell photoionization cross section. Present experimental results are compared with other experimental and theoretical values. Reasonable agreement (to within 0.3-28%) is typically obtained between present and other experimental and theoretical values.
The effect of swelling of crystalline Ge irradiated at room temperature with 30 keV Ga"+ focused ion beam (FIB) was studied by means of in situ FIB imaging, atomic force microscopy (AFM) and transmission electron microscopy (TEM). The swelling occurred in the surface region of amorphous damage layer which was formed during ion irradiation. The degree of swelling reaches values up to 10 times for an implantation dose of #approx#10"1"7 ions/cm"2. Cross-secitonal TEM examination showed that the swelling is due to formation of a porous layer with a honeycomb structure. (author). 8 refs., 4 figs.
The Micro-X instrument is a NASA funded, rocket borne X-ray imaging spectrometer planned for launch in January 2011. An array of Transition Edge Sensors (TESs) will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. This will be a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat sink, and will be read out by a SQUID time division multiplexer. X-rays will be focused onto the TES array of 128 pixels on a 600 micron pitch by a conically approximated Wolter optic with an effective area of 200 cm2. The spectrometer will have a field of view of 11.8 arcmin. We describe the design and development progress of the instrument.
The importance of point defects in semiconductor and function materials has been studied in detail, but effective means for detecting point defects has not been available for a long time. The end of range defects in Si, produced by 140 keV Ge"+ implantation, were investigated as detectors for measuring the interstitial concentration created by 42 keV B"+ implantation. The concentration of interstitial resulting from the B"+ implantation and the behavior of the interstitial flux under different annealing condition were given. The enhanced diffusion in the boron doped EPI marker, resulting from mobile non-equilibrium interstitials was demonstrated to be transient. Interstitial fluxes arising from processing can be detected by transient enhanced diffusion (TED) of doped marker layers as well
The decay of "1"0"1Mo to levels in "1"0"1Tc has been studied using the three-parameter (#gamma#-#gamma#-t) coincidence system of HpGe-HpGe detectors. From the coincidence data, the new decay scheme was constructed. The previously reported 104.70, 105.95 and 774.15 keV #gamma# rays were observed, and have been assigned to the decay scheme for the first time. A newly observed 1508.01 keV #gamma# ray has also been assigned to the scheme for the first time. The intensities of #beta#"- and the values of log ft to most levels were calculated
We have studied energy levels in "6"3Fe populated in the #beta#-decay of "6"3Mn. A new (preliminary) level scheme of "6"3Fe includes 10 excited states connected by 21 #gamma#-rays. The first excited states at 357 and 451 keV have the level half-lives of 110 ps and 780 ps, respectively. Three states, at 357, 451 and 1132 keV, are strongly #beta#-fed with log ft #approx# 5, while there is only a very week #beta#-feeding, if any at all, to the ground state. The new results imply that "6"3Fe departs from a simple shell model structure observed for heavier N = 37 isotones of "6"5Ni and "6"7Zn. (author)
The L-shell x-ray intensity ratios I(L_#beta#)/I(L_#alpha#) and I(L_#gamma#)/I(L_a_l_p_h_a) for elements with 73 #<=# Z #<=# 83 have been measured at photon incident energies of 17.8, 25.8 and 46.9 keV. The emitted x-rays were measured with a Si(Li) detector system. The results for Re, Pt and Tl are being reported for the first time. A comparison is made of the experimental results with the calculated values obtained by using the theoretical x-ray emission rates, subshell ionisation cross sections, subshell fluorescence yields and Coster-Kronig transition probabilities. The experimental results are in reasonable agreement with the theoretical values. (author).
Gamma ray spectra in the decay of 185Ta and 185mW have been studied with Ge (Li) detectors. The 185mW isomeric transition at 131.6 keV is shown to be of E3 multipolarity. A level scheme of 185W is proposed with the following energy levels (energies in keV, spin and K quantum numbers in brackets): 0 (3/2- 3/2), 23.5 (1/2- 1/2), 65.9 (5/2- 3/2), 93.5 (3/2- 1/2) (uncertain), 173.9 (7/2- 3/2), 188.1 (5/2- 1/2), 197.5 (11/2+ 11/2) , 243.5 (7/2- 7/2), and 390.8 (9/2- 7/2)
Research preformed consisted of: (1) publication of an experimental paper for the n + {sup 40}Ar high resolution total cross section and submission of a theoretical paper dealing with the prediction of the average parameters deduced from the the data; (2) preliminary R-matrix analysis of the neutron total cross section data for the n + {sup 208}Pb systems, up to an energy of 1.7 MeV; (3) completed the analysis of neutron total cross section of data for n + {sup 54}Fe up to energy of 500 keV, with j{sup {pi}} values confirmed, in most cases, by differential scattering data; (4) analysis of total cross section data for the n + {sup 88}Sr system up to an energy of 175 keV; (5) development of a graphical interface for the code RFUNC, used to calculate the differential scattering cross sections, for comparison with measurements.
The MCNPE-BO and MCNP4 Monte Carlo electron-photon codes were used to calculate the dose equivalent per unit fluence at various depths in tissue-equivalent slab phantoms for broad parallel beams of monoenergetic electrons with energies from 50 keV to 10 MeV. The study was carried out in the framework of the activities of a ICRP/ICRU Joint Task Group with the support of EURADOS WG4 (Numerical Dosimetry). Some preliminary results and comparisons as well as a general discussion on the performances of the codes are presented, demonstrating quite a satisfactory agreement among the results obtained using the two codes and those of other authors. (author).
An ytterbium-169 high dose rate brachytherapy source, distinguished by an intensity-weighted average photon energy of 92.7 keV and a 32.015#+-#0.009 day half-life, is characterized in terms of the updated AAPM Task Group Report No. 43 specifications using the MCNP5 Monte Carlo computer code. In accordance with these specifications, the investigation included Monte Carlo simulations both in water and air with the in-air photon spectrum filtered to remove low-energy photons below 10 keV. TG-43 dosimetric data including S_K, D(r,#theta#), #LAMBDA#, g_L(r), F(r,#theta#), #phi#_a_n(r), and #phi#_a_n were calculated and statistical uncertainties in these parameters were derived and calculated in the appendix.
Localized beam-processed areas using chemical reactions induced by a 30 keV Ga"+ focused ion beam (FIB) with and without I_2 (etching) and (CH_3)_3CH_3C_5H_5Pt gases (Pt deposition) have been analyzed using a 300 keV Be"2"+ microprobe with a beam spot size of 50-80 nm. The analyzed results have been compared with energy dispersive X-ray (EDX) analysis using an electron beam. The EDX analysis only indicated incorporated impurities at high fluence such as Ga, Pt and C, while microprobe RBS analysis could detect residual iodine with low concentration which couldn't be detected by EDS analysis because of the lower sensitivity of the EDX analysis for heavy atoms.
The optical emission of excited H reflected from clean Cu(110) after impingement of H/sup +/ and H/sub 2//sup +/ in the energy range of 250 eV to 20 keV per nucleon at 70/sup 0/ angle of incidence to the surface normal was measured. For incident 10 keV H/sub 2//sup +/, the highest excited hydrogen state detected was the n=10 level. The Hsub(..cap alpha..) yield was found to be fluence and energy dependent. This effect is attributed either to fast sputtered hydrogen, surface roughness or to an increase with hydrogen concentration in electron states of p-like symmetry near the Fermi level of copper. The Hsub(..cap alpha..) yield per reflected nucleon shows approximately an exponential dependence on both projectile energy per nucleon and scattered particle reciprocal velocity perpendicular to the surface.
The optical emission of excited H reflected from clean Cu(110) after impingement of H"+ and H_2"+ in the energy range of 250 eV to 20 keV per nucleon at 70"0 angle of incidence to the surface normal was measured. For incident 10 keV H_2"+, the highest excited hydrogen state detected was the n=10 level. The Hsub(#alpha#) yield was found to be fluence and energy dependent. This effect is attributed either to fast sputtered hydrogen, surface roughness or to an increase with hydrogen concentration in electron states of p-like symmetry near the Fermi level of copper. The Hsub(#alpha#) yield per reflected nucleon shows approximately an exponential dependence on both projectile energy per nucleon and scattered particle reciprocal velocity perpendicular to the surface. (orig.).
We report on recent studies of the effects of 50 keV focused ion beam (FIB) exposure on MOS transistors. We demonstrate that the changes in value of transistor parameters (such as threshold voltage, V{sub t}) are essentially the same for exposure to a Ga+ ion beam at 30 and 50 keV under the same exposure conditions. We characterize the effects of FIB exposure on test transistors fabricated in both 0.5 {micro}m and 0.225 {micro}m technologies from two different vendors. We report on the effectiveness of overlying metal layers in screening MOS transistors from FIB-induced damage and examine the importance of ion dose rate and the physical dimensions of the exposed area.
The energy dispersive beamline X6A at the National Synchrotron Light Source employs a curved crystal monochromator (polychromator) which focuses a range ([similar to]1 keV) of x-ray energies into a narrow (100--120 [mu]m) line image. Although this beamline was constructed primarily for time-dependent EXAFS experiments, we have begun to explore the use of this instrument for energy dispersive diffraction experiments with different types of sample including macromolecular crystals. The tunability ([ital E]=6.5 to 21 keV) and flexibility ([Delta][ital E]=100--1000 eV) of the instrument makes the beamline ideal as a test bed for the application of polychromatic single-crystal diffraction techniques to different chemical or biological materials.
The measurements of the K X-ray intensity ratio I(K{sub {beta}})/I(K{sub {alpha}}) for the 17 elements Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Br, Rb, Sr, Y, Zr, Nb and Mo have been done following ionization by 59.5keV {gamma}-rays from a {sup 241}Am point source. Ratios of emission probabilities of Auger electrons and the vacancy transfer coefficients have been extracted in terms of the intensity ratios. It is found that the present results agree well with earlier fitted values and the semi-empirical values.
We study the characteristics of cyclotron wave-particle interaction in a typical hydrogen plasma. The numerical calculations of minimum resonant energy Emin, resonant wave frequency ?, and pitch angle diffusion coefficient D?? for interactions between R-mode/L-mode and electrons/protons are presented. It is found that Emin decreases with ? for R-mode/electron, L-mode/proton and L-mode/electron interactions, but increase with ? for R-mode/proton interaction. It is shown that both R-mode and L-mode waves can efficiently scatter energetic (10 keV-100 keV) electrons and protons and cause precipitation loss at L=4, indicating that perhaps wave-particle interaction is a serious candidate for the ring current decay. (authors)
We review our recent work on an atomistic approach to the development of predictive process simulation tools. First principles methods, molecular dynamics simulations, and experimental results are used to construct a database of defect and dopant energetics in Si. This is used as input for kinetic Monte Carlo simulations. C and B trapping of the Si self- interstitial is shown to help explain the enormous disparity in its measured diffusivity. Excellent agreement is found between experiments and simulations of transient enhanced diffusion following 20-80 keV B implants into Si, and with those of 50 keV Si implants into complex B-doped structures. Our simulations predict novel behavior of the time evolution of the electrically active B fraction during annealing.
The precipitation hardened, ferrite-pearlite medium-carbon steels microalloyed with vanadium (AFP steels) have been developed over the last few years as materials allowing processing by controlled, continuous cooling down from forging temperatures, for achieving benefits such as reducing the number of required heat treatment and working processes and saving expensive alloying materials. Due to their cost-saving advantages, the steels rapidly have been accepted as an alternative material to the quenched and tempered steels and re particularly used for fabrication of automobile parts. Their drawbacks however are the lower yield strength, and low ductility and toughness as compared to the heat-treatable steels. The research project therefore was intended to enhance the properties of the microalloyed, medium-carbon steels and widen their applicability by establishing further and improving existing thermomechanical treatment processes that will considerably improve the steels` strength and ...
During their life, intervertebral discs undergo degenerative changes which need not necessarily become lesions. Conventional X-rays do not provide information on the condition of the intervertebral discs, so MRT or CT are recommended as primary techniques as they are non-invasive. Invasive methods like myelography and especially discography should not be used unless a case is highly problematic. In infants with pains in the back, MRT should be carried out as early as possible as there is nearly always an organic cause. (orig.) [German] Die Bandscheibe ist im Laufe des Lebens degenerativen Veraenderungen unterworfen, die klinisch zu Beschwerden fuehren koennen, aber nicht fuehren muessen. Konventionlle Roentgenaufnahmen lassen zwar die Hoehenminderung des Bandscheibenfachs und begleitende knoecherne Veraenderungen erkennen, nicht aber den Zustand der Bandscheibe selbst. Die Beurteilung der Bandscheibe und des Knochens gelingt mit der CT, die parallel zum ...
ZusammenfassungUbelkeit und Erbrechen stellen zwei Symptome dar, die grundlich untersucht worden sind und bei Krebspatienten haufig auftreten. Die meisten Studien haben sich bislang mit Haufigkeit und Management dieser beiden Symptome befasst. Das Ziel dieser Studie bestand darin, ein besseres Verstandnis dafur zu entwickeln, wie Krebspatienten ihre Symptome erleben-insbesondere Ubelkeit und Erbrechen nach Chemotherapie-und welche Auswirkungen diese Symptome auf den Tagesablauf der Patienten haben. Neun Frauen mit unterschiedlichen Krebsleiden und Chemotherapie Regimes wurden zwecks Chemotherapie stationar aufgenommen und nahmen an der Studie teil. Es wurden halbstrukturierte Interviews einschliesslich einer Inhaltsanalyse in Anlehnung an Kvale durchgefuhrt (Klarung und Entwicklung neuer B...
This comprehensive final report for the Swiss Federal Office of Energy (SFOE) presents the results of research done in the third phase of a research project that investigated components for small heat pump systems that use ammonia as a working fluid. The report includes a summary of the findings of the first two phases of the project and goes on to describe tests done with rotary vane and scroll compressors. The aims of the project are discussed and the work done is listed chronologically. The construction and the components of the test installation are described in detail. Also, the heat pump testing facilities at the University of Applied Science in Rapperswil, Switzerland, are described. The results of the measurements made for various temperature gradients are presented in detail and commented on; also, the various types of compressor tested and other heat pump compressors are compared.
Magnetic pulse welding, a cold solid state bonding process, is becoming a viable replacement for conventional fusion welding processes and explosive welding. The process is presented here along with its fundamental equations and applications of similar and dissimilar welds are illustrated along with typical interface microstructures. (orig.) [German] Magnetimpuls-schweissen, ein Verbindungsverfahren im kalten Festzustand, wird ein funktionsfaehiger Ersatz fuer das herkoemmliche Schmelzschweissverfahren und das Explosionsschweissverfahren. Das Verfahren wird hier mit seinen grundlegenden Gleichungen vorgestellt, und Anwendungen von aehnlichen und unaehnlichen Schweissungen werden mit typischen Schnittstellen-Mikrostrukturen veranschaulicht. (orig.)
Zusammenfassung Die Festigkeitshypothesen und Flie?fl?chen aus den klassischen Kursen der Mechanik (die Normalspannungshypothese, die Modelle nach von Mises und Tresca) reichen oft nicht aus, das tats?chliche Verhalten von Bauteilen unter Belastung zu erfassen. Deshalb werden in der Literatur weitere Modelle mit einem oder mehreren Parametern vorgeschlagen. Diese Modelle beschr?nken allerdings die Geometrien der zul?ssigen Formen der Fl?chen im Spannungsraum. In dieser Arbeit wird ein auf die Zugspannung normiertes Druck-Torsion-Diagramm vorgestellt, in dem sich die Modelle inkompressiblen Materialverhaltens miteinander vergleichen lassen. Mit diesem Diagramm wird der Begriff der Symmetrie der Fl?che in der ?-Ebene verdeutlicht. Die konvexen Fl?chen inkompressiblen Materialverhaltens sind ...
The article describes the solar aircraft `Icare`` which was constucted in a joint project by engineers and scientists of Stuttgart university. The aircraft requires slightly more than one kW for staying up. The theoretical fundamentals are presented in the dissertation of Peer Frank, ``Aircraft design for minimum fuel consumption` (Institute of Aircraft Engineering, Stuttgart, 1992). (orig.) [Deutsch] Allein mit Sonnenkraft kann das Flugzeug `Icare` fliegen. Es entstand in Gemeinschaftsarbeit von Ingenieuren und Wissenschaftlern der Stuttgarter Universitaet. Das Solarflugzeug Icare benoetigt etwas ueber ein Kilowatt, um oben zu bleiben. In seiner Doktorarbeit `Die Auslegung von Flugzeugen mit geringstem Antriebsleistungsbedarf` (Institut fuer Flugzeugbau, Stuttgart, 1992) hat der Duesseldorfer Peer Frank die theoretischen Grundlagen dazu behandelt. (orig.)
The Monte-Carlo transport code MCNP was used to evaluate possible arrangements of cores for the MIT Reactor using monolithic LEU fuel. Plate and moderator thicknesses were varied, and fixed absorbers and inner reflectors added in an effort to maximize available neutron fluxes at in-core and ex-core locations of experimental facilities. Addition of D_2O in the H_2O moderator was also evaluated. Comparisons of the fast, epithermal, and thermal fluxes were made at selected locations. Keff was also evaluated and critical blade heights compared with the existing HEU core. Results indicate that the LEU fluxes could approach HEU values with the use of a fueled in-core experimental facility, a fixed boron absorber spider and an inner beryllium reflector. (author)
Purpose: With intracranial tumors a flat, contrast-enhancing, probably dural structure adjacent to the tumor can occasionally be observed on gadolinium-DTPA enhanced MR images. Therefore we have attempted to evaluate a tumor infiltration of this enthancement on MRI. Material and Methods: This study included 50 patients. 19 patients had a dural thickening at the tumor base (13 meningiomas and 6 metastases), while 31 patients did not (12 meningiomas and 19 metastases). Studies included plane T{sub 2}-weighted spin echo (SE) images as well as T{sub 1}-weighted axial, coronal, or sagittal plains with and without contrast agent. Histopathological examinations, were done on the tumor base adjacent to the dura mater. Results: 7 of 12 meningiomas showed a meningeal thickening on MRI with histopathologically proven tumor infiltration as did also 5 of 6 metastases. But 3 of 12 meningiomas and 15 of 19 metastases without dural thickening at the tumor base also showed tumor invasion into the dura ...
L_#alpha#/L_l X-ray intensity ratios have been measured in elements Ta, W, Au, Hg, Tl, Pb, Bi, Th and U using L-shell photoionization by 60 keV photons. The present results are found to agree with the calculated values of Scofield within experimental uncertainties. (author).
An investigation of the Ll x-#gamma# angular correlations following the decay of "2"0"7Bi is done by using a Si(Li) semiconductor counter as L x-ray detector. Coincidence measurements at five different angles were made between the 570-keV #gamma# ray (gated in the movable counter) and the Ll x spectrum (displayed in a multichannel analyzer).
The spectrometric methods and equipment for "2"0"1Pb and "2"0"1Tl activity control in the prepared thallium chloride in industrial production are described. Estimation of thallium-201 activity is carried out in accord with the square of summary photopeak caused by #gamma#-quanta at 167 keV energy. Attenuation is paid to spectrometer calibration. 5 refs.; 2 figs.; 2 tabs.
Lead-203 [52.1 h, 279 (80.1%) KeV] has been recognized as a potentially useful tracer for tumor specific radiopharmaceuticals due to its favorable nuclear and chemical properties. This paper reports the cyclotron production of lead-203 and the labelling of monoclonal antibody B72.3, conjugated with 2-(p-isothiocyanatobenzyl)DOTA, with lead-203 in 30% yield. In vivo biodistribution and stability studies in mice are being conducted.
The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.
We describe the continued development of a portable, real-time neutron spectrometer. The spectrometer is composed of two distinct detector systems: a Helium 3 gas filled proportional counter for the lower neutron energy interval between 20 KeV and 2 MeV and a bulk silicon solid state detector for the higher energy interval between 2 MeV and 500 MeV. Modeling and experimental results with mono-energetic neutron beams are reported.
To suppress space charge blowup in an ion beam passing through a photoneutralizer, it is necessary to introduce some background gas. An analysis is presented of the neutralization of a high-energy, >200-keV negative deuterium ion beam, exposed to photodetachment while in the presence of deuterium. With a gas thickness of <0.01 Torr.cm, the neutral fraction in the output beam is found to be about the same as that gotten from the photoneutralizer operating in vacuum. Neutral atom beam injection for plasma heating is discussed.
A study of the 150-300 keV proton beam transmission through glass (borosilicate) tapered capillaries with different diameters of the input and output of the capillary was performed. The focusing effect was observed. The areal density of the transmitted beam is enhanced by approximately 20 times. It was shown that changing a taper angle from 0.5 deg to 1.7 deg evidences the increase of the transmission coefficient more than by 300 times keeping the initial energy spectrum of ions. (author)
The capture cross sections of Am 242m can be deduced from resonances analysis at low energy and computed with theoretical models at high energy. In this work, a coherent set of cross sections which reproduced the experimental values of the fission cross sections is computed. These calculations were performed for an energy of the incoming neutron between 1 keV and 1 MeV.
Molar extinction coefficients for the solid solutes in aqueous solutions of some alkaline earth chlorides such as MgCl_2.6H_2O, CaCl_2, SrCl_2.6H_2O and BaCl_2.2H_2O have been determined at 81, 356, 511, 662, 1173 and 1332 keV energies in different concentration using the narrow beam transmission methods. (author)
The magnetic moments of "1"7"7Ta and sup(181,182,187)Re levels decaying via the K-forbidden transitions are measured. The nuclei studied are produced via the "1"7"7W and sup(181,182)Os and "1"8"7W #beta#-decay respectively. The magnetic moments have been measured using the method of the differential #gamma##gamma# angular correlations, perturbed by an external magnetic field. The following magnetic moments and lifetimes are obtained: for the 5/2"-1/2"-[541] "1"8"1Re level with excitation energy of 357 keV #mu#/#mu#sub(n)=2.00+-0.10, Tsub(1/2)=(76+-8)x10sup(-8) s; for the 186.4 keV 5/2"-1/2"-[541] "1"7"7Ta level #mu#/#mu#sub(n)=2.02+-0.13, Tsub(1/2)=(2.78+-0.09)x10sup(-6) s; for the 236 keV 2"- "1"8"2Re level #mu#/#mu#sub(n)=2.12+-0.08; for the 203 keV 9/2"- [514] "1"8"7Re level #mu#/#mu#sub(n)=5.04+-0.09.
An experimental investigation was made of the ..gamma..-transitions feeding or de-exciting the 1355 keV isomeric state in /sup 177/Ta. The E2/M1 mixing ratios for the 311 keV interband transition from the isomer and for the 271 keV and the 295 keV intraband transitions within the rotational band on the isomer were determined to be delta = 0.29sup(+0.11)sub(-0.06), 0.25sup(+0.05)sub(-0.03) and 0.30sup(+0.06)sub(-0.08), respectively, employing combined measurements of the linear polarization and angular distribution of the ..gamma..-ray with the aid of conversion electron measurements. Spin and parity assignments of the isomer were confirmed to be 21/2/sup -/. The half-life of the isomer was remeasured to be Tsub(1/2) = 5.0 +- 0.2 ..mu..s and the magnetic moment was found to be ..mu.. = 0.080 +- 0.014 ..mu..sub(N). The gsub(K) and gsub(R) factors for the band on the isomer were deduced separately to be ...
An experimental investigation was made of the #gamma#-transitions feeding or de-exciting the 1355 keV isomeric state in "1"7"7Ta. The E2/M1 mixing ratios for the 311 keV interband transition from the isomer and for the 271 keV and the 295 keV intraband transitions within the rotational band on the isomer were determined to be delta = 0.29sup(+0.11)sub(-0.06), 0.25sup(+0.05)sub(-0.03) and 0.30sup(+0.06)sub(-0.08), respectively, employing combined measurements of the linear polarization and angular distribution of the #gamma#-ray with the aid of conversion electron measurements. Spin and parity assignments of the isomer were confirmed to be 21/2"-. The half-life of the isomer was remeasured to be Tsub(1/2) = 5.0 +- 0.2 #mu#s and the magnetic moment was found to be #mu# = 0.080 +- 0.014 #mu#sub(N). The gsub(K) and gsub(R) factors for the band on the isomer were deduced separately to be gsub(K=21/2"-) = ...
Auger-electron emission from different silicides has been studied for 4 and 10 keV Ar ion excitation. The intensity of the SiLMM Auger line changes significantly with channing concentration and atomic number of the metal-parthner. The experimental results can be explained in terms of a simple model based on the probability of Si-Si collision symmetric cascade in these binary compounds.
The results of Sandia National Laboratories' participation in the NASA Planetary Definition and Design Program are summarized. Areas reported include the characterization of large area cadmium zinc telluride spectrometers and the application of simulation techniques to the prediction of device performance. Also investigated was the response of mercuric iodide devices in the region from 1 to 100 KeV. A literature study to determine the status or radiation damage measurements in room temperature semiconductor devices is also reported.
The Ksub(#beta#)/Ksub(#alpha# 12) x-ray intensity ratio of the Si K spectrum was measured for proton impact on Si0_2 in the energy range 300-800 keV. An energy dependence of the intensity ratio was found and an explanation is given in terms of multiple ionisation. (author).
Measurements of the double-electron-capture process in which a positive ion of iodine becomes a negative ion in a single collision with a magnesium atom are reported between 20 and 90 keV. The cross section is comparable to that for the rare gases and not as large as might be expected from a two-valence-electron atom. This process is probably insignificant in the production of negative ion beams using a magnesium-vapor target.
The INTEGRAL/SPI spectrometer was designed to observe the sky in the energy band of 20 keV to 8 MeV. The specificity of instrument SPI rests on the excellent spectral resolution (2.3 keV with 1 MeV) of its detecting plan, composed of 19 cooled germanium crystals; covering an effective area of 508 cm{sup 2}. The use of a coded mask, located at 1.7 m above the detection plan ensures to it a resolving power of 2.5 degrees. The aim of this thesis, begun before the INTEGRAL launch, is made up of two parts. The first part relates to the analysis of the spectrometer calibration data. The objective was to measure and check the performances of the telescope, in particular to validate simulations of the INTEGRAL/SPI instrument response. This objective was successfully achieved. This analysis also highlights the presence of a significant instrumental background noise. Whereas, the second part concentrates on the data analysis of the Vela region ...
The decay of molybdenum-101 has been investigated using the three-parameter (#gamma#-#gamma#-t) coincidence system of HPGe-HPGe detectors. According to the off-line analysis, the decay scheme was modified. The positions of 221.80, 318.00, 377.90; 452.50, 515.42, 1011.05, and 1759.72 keV transitions have been arranged again, the transition positions of 104.70, 105.95, and 774.15 keV gamma rays have been assigned for the first time, the positions of 169.00, 590.91, 980.52, and 1431.68 keV transitions have been reconfirmed, and the 1508.01 keV gamma ray was observed simultaneously for the first time and its transition position has been assigned. The #beta#"- intensities and the values of log ft of most levels were calculated. Combining with the high-spin states observed by the in-beam #gamma#-ray spectroscopy of previous decay works, the structure of the excited positive/negative-parity yrast states of ...
We conducted (n, #gamma#) and (d, p) reactions leading to "8"7", "8"8", "8"9"Sr in addition to "8"8Sr (d, t) "8"7Sr and 24 keV neutron capture in "8"8Sr. (orig./HSI).
Chemical effects on the intensity ratio of LX-ray of molybdenum compounds irradiated by 11-keV electrons and by 3-MeV protons were studied using an x-ray crystal spectrometer. It was found that the intensity ratios of L_#gamma#_1/L_#beta#_1 markedly decrease with the increase of ionicity of molybdenum compounds, except for the case of metallic molybdenum. (author).
This update of a system concept entitled ``Maritime hazard prevention and water protection`` makes full use of the technical room for maneuver while considering that reasonable financial and economic conditions must be provided. The update allows on to continue or start the exploitation of feasible technical, logistic and information-technology development potentials. The same applies to the national maritime traffic safety measures developed for the German waterways. Considering the maritime hazards that have been prevailing in the coastal areas of the German North Sea, the conducted damage risk investigations suggest that a large-scale, disastrous oil contamination of the mud flats ecosystem cannot be excluded or controlled definitely in spite of the numerous measures taken. (orig.) [Deutsch] Mit der vorgelegten Fortschreibung zum Systemkonzept ``Gefahrenabwehr und Gewaesserschutz im Seeverkehr`` werden die technisch realisierten Handlungsspielraeume unter ...
A whole sequence of the parameters of the combined heat and power system (KWK) is described which enables a comparison between the electricity and heat demand of a consumer and the energy availability through a combined heat and power system. Proceeding from this, a thermodynamic model of a steam and gas process with combined heat and power is introduced which is based on an exergetic balancing of the subsystems of the process. In this way, the varying thermodynamic quality of the energy flows occuring in the process will be taken into consideration so that the results of the model correspond in any case with the second law of thermodynamics. (orig.) [Deutsch] Es wird ein vollstaendiger Satz von Kenngroessen der Kraft-Waerme-Kopplung (KWK) beschrieben, mit dessen Hilfe der Strom- und Waermebedarf eines Verbrauchers mit der Energiebereitstellung durch eine KWK-Anlage verglichen werden kann. Darauf aufbauend wird ein thermodynamisches Modell des ...
In a prospective study 102 patients with malignant tumors of the tongue, oropharynx, hypopharynx, and larynx were staged by means of MRI. Special attention was directed at those tumour extensions that could influence the treatment strategy. The MR findings were correlated with the results of palpation, endoscopy, ultrasound, computerised tomography and histopathological findings. MRI showed a good delineation of pT{sub 2} to pT{sub 4} tumours. However, visualisation of small tumours in the soft palate, the tonsils, the pyriform sinuses and vocal cords was difficult. In conclusion our results suggest that in addition to endoscopy MRI is a valuable tool for the examination of tumours of tongue, oropharynx, hypopharynx and larynx. (orig.) [Deutsch] In einer prospektiven Studie wurden 102 Patienten mit malignen Tumoren der Mundhoehle, des Oro- und Hypopharynx sowie des Larynx mit der Mgnetresonanztomographie (MRT) untersucht, wobei besonders Wert ...
The brochure reports on the construction and method of operation of heat pumps: - Efficiency and temperature difference - output figure - circuit processes - saving of primary energy - monovalent and bivalent plants - absorber, earth collectors - heat recovery. (HW) [Deutsch] Die Broschuere berichtet ueber den Aufbau und die Wirkungsweise von Waermepumpen: - Wirkungsgrad und Temperaturdifferenz - Leistungszahl - Kreisprozesse - Einsparung von Primaerenergie - monovalente und bivalente Anlagen - Absorber, Erdkollektoren - Waermerueckgewinnung. (HW)
It is demonstrated that highly dispersed molybdenum sulfide catalysts are prepared by using Mo(CO){sub 6} adsorbed on the support. The structure of ultradispersed molybdenum sulfide is suggested by EXAFS techniques to be different from that of MoS{sub 2}. The TOF of the thiophene HDS is almost invariant with the dispersion of molybdenum sulfide at a high molybdenum dispersion, whereas the TOF of the hydrogenation greatly increases with increasing dispersion. On the basis of the HDS activity and optimum Co/Mo ratio of Co-Mo/Al{sub 2}O{sub 3} catalysts having a variety of molybdenum dispersion fabricated by using carbonyl complexes, it is demonstrated that highly active HDS catalysts are prepared by highly dispersing molybdenum sulfide phases. Edge decorations of molybdenum sulfides by cobalt are suggested for the synergy generation between cobalt and molybdenum sulfides. (orig.) [Deutsch] Unter Verwendung von auf dem Traeger adsorbierten Mo(CO){sub 6} lassen sich hochdispergierte ...
The paper industry needs alternative waste disposal methods rather than dumping sites. The combustion properties of these waste materials make them suitable for thermal disposal. A process has been developed in which the waste materials are burnt on an oscillating bar grate without supplying external energy. Electrical energy and process steam are generated while small amounts of a sintered slag remain behind. (orig.).
A cathode of improved discharge characteristics for a zinc-air battery is prepared from mixtures containing gamma-MnO/sub 2/ 33-67 wt%, C 12-40 wt% and KOH 20-28 wt%.
The book is a German translation of an American textbook with the original title ''MRI Survival Guide'' and is intended to serve as an introductory guide for beginners or a reference book for quick information. Readers will find information on the fundamentals of the technology and methodology of MRI as well as all details of relevance to practice in a precise and easy-to-grasp arrangement, covering all anatomic areas of interest, illustrations and descriptions of characteristic signs of pathologic processes, high-quality and unusually large-sized diagnostic pictures, a modern didactic concept for quick orientiation, including surveys, tables, and reproductions for visualisation of contents. (orig./CB) [German] Praktisch jeder Mediziner wird im Laufe seiner Berufstaetigkeit mit der MRT konfrontiert - unabhaengig davon ob in der Radiologie, Orthopaedie, Gynaekologie, Chirurgie, Neurologie oder sonstigen Fachrichtung. Das Buch ist ...
The purpose of the present study was to examine reactions between bromium atoms with {alpha}, {beta}-unsaturated carbonyls. Acrolein, methacrolein, and methyl vinyl zetone were chosen as representatives of this family. The latter two compounds, beside formaldehyde, belong to the main products of atmospheric oxidation of isoprene and have been detected in the troposphere at concentrations of up to almost 1 ppb. It is known that alkenes react with bromium via addition to form an instable adduct. This product can either decompose again into its educts or react with molecular oxygen. The aim of the study was to determine the velocities of the reactions between the three {alpha}, {beta}-unsaturated carbonyls and bromium and to clarify the involved reaction mechanisms by means of kinetic experiments and product analyses. (orig./SR) [Deutsch] In dieser Arbeit wurde die Reaktion von Bromatomen mit {alpha}, {beta}-ungesaettigten Carbonylen untersucht. Ausgewaehlt wurden ...
Steam turbines of the new power plant generation enable the realisation of over-critical steam parameters with 600 C and 300 bar by means of simple and double resuperheating. Extensive research work in the field of material technology has provided the pre-conditions. Forged pieces, castings, high-temperature ferritic 9 - 10 % CrMoV steels, which are additionally alloyed with niobium, nitrogen and wolfram, are used in steam turbines. A proof of strength for shaft and cast steels is available by means of a long-term stress-rupture test of up to max. 60,000 hours. The strength of turbine steels exceeds the one in tube and header steels (x 10 CrMoVNbN 9 1). (orig./MM) [Deutsch] Dampfturbinen der neuen Kraftwerksgeneration erlauben heute die Realisierung von ueberkritischen Dampfparametern mit 600 C und 300 bar mit einfacher und zweifacher Zwischenueberhitzung. Umfangreiche werkstofftechnische Forschungsarbeiten haben dafuer die Voraussetzung ...
The enhancements described of high-performance CT systems of latest design have again confirmed the importance of CT systems for acute and selective diagnostic imaging. Higher availability, shorter exposure times, and better applicability and handling for examination of poly-traumata patients or patients of intensive care departments are some of the advantages achieved with CT systems which demonstrate CT system efficiency in addition to MRI, which for specific examinations will remain the modality of first choice for diagnostic evaluation. The Tomoscan Av-E presented here was able to answer all relevant diagnostic questions appearing in routine diagnostics and scientific work. For patients, examinations using the spiral CT technique also offers significant advantages. (orig./CB) [Deutsch] Durch die dargestellten Verbesserungen bei Hochleistungs-CT-Systemen neuester Bauart wurde die Bedeutung der CT fuer die akute und selektive Diagnostik erneut bestaetigt. Bessere Verfuegbarkeit, ...
According to the invention, a zinc foil is arranged between the negative electrode of a zinc/air battery (round cell) and the expansion space compensating for the reactive increase in volume of the zinc powder. This zinc foil functioning as a stop diaphragm particularly ensures, from the very onset, that the zinc filling has a density and compactness necessary for good electronic conductance.
The composition of alkaline and neutral boric acid containing evaporator concentrates resulting from the treatment of radioactive waste water in nuclear power plants with WWER reactors is described as well as the processing of these concentrates to a product suitable for final disposal. Tests with mock solutions of these evaporator concentrates have been performed at the laboratory and teststand scale to produce a dry residue by continuous thickening, which can be processed into a highly leach resistant product, suitable for final disposal, by cementation. Ca-compounds must be added to the evaporator concentrates prior to the drying in an rotary thin-film evaporator (RTFE). The tests showed that neutral evaporator concentrates can be dried in a RTFE with addition of small amounts of Ca-compounds. The alkaline evaporator concentrates with high boric acid and total salt load require a multiple amount of Ca-compounds and diluting water to perform the drying process. A brief description of ...
In rare cases, large adrenal masses with a suspicion of malignancy exhibit tumor extension into the adrenal vein and inferior vena cava. When planning surgery, the relationship of the extension to the inferior vena cava is of decisive improtance. We describe in two cases on the detection of a tumor thrombus in the inferior vena cava arising from a malignant adrenal mass by means of MR angiography (TOF, coronary 2D GRE images [FLASH], 3 slices acquired during 15 second apnea). The angiograms correlated well with the results of DSA venacavography and with the intraoperative findings. Thus, MRA has been demonstrated to be suitable for the certain proof of a venous tumor thrombus not only in cases of renal cell carcinomas but also in cases of malignant adrenal masses. The method should be applied whenever there is evidence of a venous involvement in the adrenal MR images. (orig.) [Deutsch] Grosse malignomverdaechtige Nebennierentumoren zeigen in seltenen Faellen eine Tumorausdehnung in die ...
The technical rule intends to maintain the function of the safety facilities in case of explosion hazards resulting from materials capable of generating explosive atmospheres or forming explosive mixtures if such materials are brought or released into the nuclear facility or are generated on site. (orig.).
The technical rule intends to maintain the function of the safety facilities in case of explosion hazards resulting from materials capable of generating explosive atmospheres or forming explosive mixtures if such materials are brought or released into the nuclear facility or are generated on site. (orig.).
The direct injection Diesel engine with its specific fuel consumption of about 200 g/kWh is one of the most efficient thermal engines. However in case of relatively low CH- und CO-emission the soot- and NO{sub x} concentration in the exhaust gas turns out to be a problem with respect to the legislation on emission limits. At the department of piston- and turbo-machines of the Trier University of Applied Sciences, a single-cylinder testing engine with two injection-systems (fuel and water) has been developed. This engine has been constructed to analyse the effect of stratified water-injection on the soot- and NO{sub x} emissions of exhaust gases of a Diesel engine. (orig.) [German] Der Dieselmotor mit Direkteinspritzung stellt mit spezifischen Kraftstoffverbraeuchen in der Groessenordnung von 200 g/kWh eine der wirtschaftlichsten thermischen Kraftmaschinen dar. Bei relativ niedrigen Kohlenwasserstoff- und Kohlenmonoxid-Emissionen erweist sich ...
Abstract Der folgende Artikel setzt die Reihe unserer ChiuZ-Beitrge zur Chemi- und Biolumineszenz mit einer interessanten und neuen experimentellen Arbeit zum -kalten Licht- spezieller ungesttigter Verbindungen fort, deren Anwendung auch in der modernen Zeit der Nanotechnologie im biochemischen bzw. medizinisch-chemischen Labor vllig neue Akzente gesetzt hat.
Between October 1990 and March 1991, 8 patients with cystic lesions in the region of the posterior bladder wall, the seminal vesicles and the prostate were examined by MRI. In all cases there was accurate characterisation of the lesion and of its anatomy. In 3 patients with abnormalities in the retrovesical space there was very good agreement with the operative findings. 4 patients were treated conservatively. In these patients there was good agreement with the findings on cystoscopy, CT and sonography. (orig.).
The creep behaviour of boiler drums of CuNiMo steels depends on the ratio of the alloys, the heat treatment and the processing technology. Reduction in deformability must be expected but, under optimum conditions, this does not lead to a critical material condition. The appropriate material tests are indispensable. (orig.)
Purpose: Liposarcoma is the most common soft tissue sarcoma in adults. The purpose of the study was to correlate MR imaging features with the four ICD subclasses. Methods: 28 patients with liposarcoma were examined preoperatively on a 1.0 T MRI system, using spin echo sequences, gradient echo imaging and STIR sequences. In all patients, classification of the liposarcomas was made by histologic diagnosis (ICD-10-M-classification). Results: Well differentiated liposarcomas (9 patients) showed a number of MRI features consistent with lipoma (well defined mass high signal intensity (SI) on T{sub 1} images, low signal on T{sub 2} images, no or only little signal increase of tumour tissue after contrast material application, no necrosis). Not well differentiated liposarcomas (myxoid 14 patients, pleomorphic three patients, round cell two patients) revealed the largest part of the mass to be of low SI on T{sub 1}-weighted images. Only scattered fatty islands and septa (9 patients with myxoid ...
Purpose: The determination of tumor volume in ocular tumors is very important for the planning and success of radiation therapy. This study uses an animal model to evaluate the accuracy of MR-based volumetry of ocular tumors. Materials and methods: In a total of 25 porcine eyes obtained from the slaughterhouse, ocular tumors were produced by injecting a mixture of hand creme and Gd-DTPA under ophthalmoscopic guidance. The injected volume varied between 0.05 ml and 2.7 ml. The eyes were examined with a 1.5 Tesla scanner and a 4 cm circular surface coil especially developed for ocular MRI. After data transfer to a separate workstation, volumetric analysis was carried out by three independent radiologists using semiautomated software. The determined volume was compared with the injected volume. Results: Of the 25 prepared porcine eyes, 23 were suitable for volumetric analysis. The injection of the mixture of hand creme and GD-DTPA produced two different types of tumors. ...
Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T{sub 2}-weighted turbo-spin-echo (TSE) and T{sub 1}-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm{sup 2}. Lymph nodes with a diameter of {>=}8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes ({>=} 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of 24 cases MR findings were true negative (specificity 92%). Diagnostic accuracy was 91%. Conclusion: High-resolution MR imaging ...
Magnetic resonance imaging (MRI) of the lung is challenging because of substantial drawbacks. However, lung pathologies that are associated with increased attenuation values in CT enhance visualization in MRI: proton density is increased and tissue-air interfaces, resulting in susceptibility artifacts, are reduced in pneumonia, pneumonitis, edema, and carcinoma. On the other hand, many lung diseases result in shortness of breath, so that patients cannot hold their breath for long periods. Therefore, fast imaging techniques are required which should also allow for high spatial resolution so that small lesions can be detected. Calcifications and air pockets within lesions are not readily recognized with MRI. Thin section CT is standard for the diagnosis of pneumonia. With parallel imaging techniques, MRI examination of the lungs can be performed with short periods of breath holding, which allow for sub-centimeter resolution in the z-axis. Especially for follow-up examinations in ...
Materials and methods: 12 patients with 22 coronary bypass grafts underwent intraoperative flow quantification using the transit time ultrasound method. These values were compared to postoperative MR phase shift measurements. Flow measurements were performed preoperatively in 28 coronary arteries of 20 patients. For flow measurement, we used a velocity-encoded k-space segmented gradient echo sequence with a temporal resolution of 110 or 125 ms, respectively. 6-8 pase shift images could be acquired during one cardiac cycle. Results: There was a significant correlation between intraoperative and flow measurements using velocity-encoded MR imaging (r=0.76, p<0.0001, t-test). Flow volumes determined by MR imaging were systematically larger than those determined by the transit time ultrasound method. Mean flow in coronary arteries was reduced in severely stenosed vessels (>70%) compared to normal vessels. Intra- and interobserver variability were 10.5 and 15% (coronary bypass ...
T{sub 2} weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T{sub E}=90 ms, T{sub R}=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good quality. Compared with CT, contrast is better with MRT, offering diagnostic advantages for MRT. (orig./MG) [Deutsch] Zuerst wurde an ...
Purpose: `Exoscopic` and endoscopic identification of colorectal pathologies via MRI. Methods: 5 patients (36-88 years), two normal and three with different colorectal pathologies (diverticular disease, polyps and carcinoma of the colon), were examined by MRI after colonoscopy. Subsequent to filling of the colon with a gadolinium-water mixture under MRI-monitoring, 3D-data sets of the colon were acquired in prone and supine positions over a 28 sec breathold interval. Subsequently multiplanar T{sub 1}-weighted 2D-sequences were acquired before and following i.v. administration of Gd-DTPA (0.1 mmol/kg BW). All imaging was performed in the coronal orientation. The 3D-data were interactively analysed based on various displays: Maximum intensity projection (MIP), surface shadowed display (SSD), multiplanar reconstruction (MPR), virtual colonoscopy (VC). Results: All of the colorectal pathologies could be interactively diagnosed by MPR. On MIP images some pathologies were missed. VC ...
Purpose: To assess the new method of 3-dimensional echocardiography in comparison to the 'gold standard' MRI as to its ability to calculate left ventricular volumes in patients with congenital heart disease. Materials and methods: Eighteen patients between the ages of 3.9 to 37.3 years (mean: 12.8{+-}9.7) with a geometrically abnormal left ventricle were examined using a 1.5 T scanner with a fast gradient-echo sequence (TR=14 ms, TE=2.6-2.9 ms, FOV=300-400 mm, flip angle=20 , matrix=128:256, slice thickness=5 mm, retrospective gating) in multislice-multiphase technique. Transthoracic 3D-echocardiography was performed with a 3.5 MHz transducer and a Tomtec {sup trademark} (Munich, Germany) system for 3D reconstruction. Results: Volume calculation was possible in all patients with 3D-echocardiography, but the muscle mass calculation only succeeded in 11 to 18 patients (61%) due to inadequate visualization of the entire myocardium. Comparing MRI and 3D-echocardiography, ...
The RCP method was designed as a residue-optimised alternative to the thermally optimised grate firing of residual wastes. Its technical realisation and development to market maturity took no more than 5 years. In the first process stage the waste is converted to high-carbon pyrolysis charcoal and high-rank gas in the absence of oxygen. In the second stage these substances are oxidised by addition of oxygen. The resulting temperature causes the non-combustible constituents of the slag to melt. In a third, optional, stage this molten slag can be liberated of (heavy) metals to such an extent that it can subsequently be used directly as additive for grinding. Further exhaust gas treatment is facilitated by the use of a circulatory fluidised-bed secondary combustion chamber. Despite the reduced flue gas volume and resultant higher pollutant concentrations in the crude gas, overall emissions are lower than in conventional plants. [Deutsch] Das reststoffoptimierte RCP Verfahren ist als ...
Policy strategies for the promotion of electricity from renewable energy sources differ significantly among the Member States of the European Union with respect to the amount of additional installed capacity as well as concerning the country-specific support costs. The present report aims to assess the effectiveness and the economic efficiency of the support policies in the EU based on both historical experiences and prospective model-based analysis. The main message of the investigation is that the most effective policy instruments tend to be cost-efficient at the same time. In particular, feed-in tariff systems were identified as a successful instrument for supporting renewable energies in terms of effectiveness and efficiency, whereas quota systems still have to prove themselves in practice. (orig.) [German] Bezueglich des Erfolges bei der Foerderung erneuerbarer Energietraeger im Stromsektor bestehen deutliche Unterschiede zwischen den Mitgliedsstaaten der Europaeischen Union. Dies ...
About 25 years after the last edification of a new large high voltage institute at Technical University of Karlsruhe and about 10 years afte the edification of the test lab at Kaiserslautern University, the Brandenburg Technical University of Cottbus had the opportunity to design new high voltage test facilities from the very beginning on and to realize it in a very short time. To review the project from the first ideas followed by the planning and realization phase and the final commissioning of the technical equipment, this book should be a contribution to spred the experiences made among interested people and to demonstrate the actual technical possibilities. To ensure an international exchange of these experiences, all co-authors to the trouble to translate their participation's also to the English language. (orig.) [German] Etwa 25 Jahre nach dem letzten grossen hochspannungstechnischen Institutsneubau in der deutschen Hochschullandschaft an der TH Karlsruhe, bzw. 10 ...
Purpose: To determine the value of MRI in the preoperative evaluation of chronic paranasal sinusitis and to compare the results with CT and intraoperative findings. Method/Materials: 42 patients with clinical signs of chronic paranasal sinusitis underwent MRI after CT evaluation on one day, with subsequent functional endoscopic sinus surgery on the next day. Coronary CT was obtained with 5-mm slices and table-feed in the prone position, while MRI was performed in the supine position with coronary T{sub 2}-TSE+pd and coronary and transverse HASTE, each with 5-mm slice thickness. Aquisition time in MRI was less than 8 minutes. Two radiologists reviewed the CT and MRI scans for signs of sinusitis and detection of anatomical landmarks. The results were correlated with the intraoperative findings. Results: MRI offered no artifacts of dental work and showed more often high quality pictures than CT. CT and MRI demonstrated a good correlation in the detection of mucosal pathologies ...
High temperature components of power plants are in many cases subjected to variable loading conditions such as cyclic creep or strain cycling. Therefore the cyclic behaviour of important heat resistant steels has been investigated under stress control and to a smaller extent under strain control. The behaviour under cyclic creep rupture conditions was determined in long term experiments covering a wide range of loading conditions. This behaviour can be described with the modified life fraction rule and a factor concept of relative life for single stage cycles and additionally with a multistep hypothesis for multi-stage cycles. The description can be adapted to estimate the life consumption under service type random conditions. The strain cycling behaviour was investigated in regard to the conditions of the heated surface of large components. To simulate this type of loading and to generate long term creep fatigue data, a service type strain cycle was developed. Anisothermal and ...
We measure the transient enhanced diffusion of shallow molecular-beam-epitaxy grown marker layers of Sb and B due to deep MeV Si{sup +} ion implants at very high doses ({approx}10{sup 16}cm{sup {minus}2}). We expect the near-surface region of these implants to be vacancy rich, and we observe transient enhanced diffusion of Sb (the classic vacancy diffuser). The large enhancements imply a significant vacancy supersaturation ({approx}700 at 740{degree}C). Double implantation of the high-dose MeV Si followed by a shallow (40 keV) Si implant and annealing produces a greatly reduced number of {l_brace}311{r_brace} defects compared to a 40 keV implant into virgin Si, again consistent with a vacancy-rich region in the near-surface region of an MeV implant. However, the shallow B marker layers also show transient enhanced diffusion for the same MeV implant under similar annealing conditions, implying that an interstitial supersaturation is present at ...
We measure the transient enhanced diffusion of shallow molecular-beam-epitaxy grown marker layers of Sb and B due to deep MeV Si"+ ion implants at very high doses (#approx#10"1"6cm"-"2). We expect the near-surface region of these implants to be vacancy rich, and we observe transient enhanced diffusion of Sb (the classic vacancy diffuser). The large enhancements imply a significant vacancy supersaturation (#approx#700 at 740 degree C). Double implantation of the high-dose MeV Si followed by a shallow (40 keV) Si implant and annealing produces a greatly reduced number of #left brace#311#right brace# defects compared to a 40 keV implant into virgin Si, again consistent with a vacancy-rich region in the near-surface region of an MeV implant. However, the shallow B marker layers also show transient enhanced diffusion for the same MeV implant under similar annealing conditions, implying that an interstitial supersaturation is present at the same ...
High-power arc lamp design has enabled ultrahigh-temperature (UHT) annealing as an alternative to conventional rapid thermal processing (RTP) for ultrashallow junction formation. The time duration of the UHT annealing technique is significantly reduced from those obtained through conventional RTP. This difference in time may offer the ability to maintain a highly activated ultrashallow junction without being subjected to transient enhanced diffusion (TED), which is typically observed during postimplant thermal processing. In this study, two 200-mm (100) n-type Czochralski-grown Si wafers were preamorphized with either a 48- or a 5-keV Ge"+ implant to 5x10"1"4 cm"2, and subsequently implanted with 3-keV BF_2"+ molecular ions to 6x10"1"4 cm"2. The wafers were sectioned and annealed under various conditions in order to investigate the effects of the UHT annealing technique on the resulting junction characteristics. The main point of the paper is ...
Transient enhanced diffusion (TED) of boron in silica after low energy boron implantation and annealing was investigated using boron-doping superlattices (DSLs) grown by low temperature molecular beam epitaxy. Boron ions were implanted at 5, 10, 20, and 40 keV at a constant dose of 2{times}10{sup 14}/cm{sup 2}. Subsequent annealing was performed at 750{degree}C for times of 3 min, 15 min, and 2 h in a nitrogen ambient. The broadening of the boron spikes was measured by secondary ion mass spectroscopy and simulated. Boron diffusivity enhancement was quantified as a function of implant energy. Transmission electron microscopy results show that {l_angle}311{r_angle} defects are only seen for implant energies {ge}10 keV at this dose and that the density increases with energy. DSL studies indicate the point defect concentration in the background decays much slower when {l_angle}311{r_angle} defects are present. These results imply there are at least ...
We report results of the 2006 April multi-wavelengths campaign of SS 433, focusing on X-ray data observed with Suzaku at two orbital phases (in- and out-of- eclipse) and simultaneous optical spectroscopic observations. By analyzing the Fe25 K_alpha lines originating from the jets, we detect rapid variability of the Doppler shifts, dz/dt ~ 0.019/0.33 day^-1, which is larger than those expected from the precession and/or nodding motion. This phenomenon probably corresponding to "jitter" motions observed for the first time in X-rays, for which significant variability both in the jet angle and intrinsic speed is required. From the time lag of optical Doppler curves from those of X-rays, we estimate the distance of the optical jets from the base to be ~(3-4) \\times 10^14 cm. Based on the radiatively cooling jet model, we determine the innermost temperature of the jets to be T_0 = 13 +/- 2 keV and 16 +/- 3 keV (the average of the blue and red jets) ...
The neutron capture cross sections of Sr-88 and Y-89 were measured in a quasi-stellar neutron spectrum for kT = 25 keV via the activation method. Relevant systematic uncertainties were determined experimentally by repeated activations under different conditions and with different samples. Gold was used as a cross section standard. The resulting stellar cross sections for kT = 30 keV are 6.13 + or - 0.18 mbarn for Sr-88 and 19.0 + or - 0.6 mbarn for Y-89. The partial cross section Sr-86(n, gamma) Sr-87m was measured to 48.1 + or - 1.2 mbarn. Compared to previous data, the associated uncertainties are reduced by factors of 3 and 5, respectively. The implications for s-process nucleosynthesis around magic neutron number N = 50 are discussed in the light of new information on neutron density and temperature. 38 refs.
The neutron capture cross sections of Sr-88 and Y-89 were measured in a quasi-stellar neutron spectrum for kT = 25 keV via the activation method. Relevant systematic uncertainties were determined experimentally by repeated activations under different conditions and with different samples. Gold was used as a cross section standard. The resulting stellar cross sections for kT = 30 keV are 6.13 + or - 0.18 mbarn for Sr-88 and 19.0 + or - 0.6 mbarn for Y-89. The partial cross section Sr-86(n, gamma) Sr-87m was measured to 48.1 + or - 1.2 mbarn. Compared to previous data, the associated uncertainties are reduced by factors of 3 and 5, respectively. The implications for s-process nucleosynthesis around magic neutron number N = 50 are discussed in the light of new information on neutron density and temperature. 38 refs.
The neutron capture cross sections of Sr-88 and Y-89 were measured in a quasi-stellar neutron spectrum for kT = 25 keV via the activation method. Relevant systematic uncertainties were determined experimentally by repeated activations under different conditions and with different samples. Gold was used as a cross section standard. The resulting stellar cross sections for kT = 30 keV are 6.13 + or - 0.18 mbarn for Sr-88 and 19.0 + or - 0.6 mbarn for Y-89. The partial cross section Sr-86(n, gamma) Sr-87m was measured to 48.1 + or - 1.2 mbarn. Compared to previous data, the associated uncertainties are reduced by factors of 3 and 5, respectively. The implications for s-process nucleosynthesis around magic neutron number N = 50 are discussed in the light of new information on neutron density and temperature.
Neutron elastic and inelastic scattering cross sections of _2_3_8U and _2_3_2Th have been measured at the University of Lowell for states below 1.8 MeV. A time-of-flight (TOF) spectrometer was used. The disc-shaped scatterer was oriented to optimize energy resolutions for 200-to-500-keV neutrons. Neutrons were obtained via the _7Li(p,n)_7Be reaction. Targets were prepared by in-situ evaporation of Li onto a Ta backing. During the evaporation, the target thickness was monitored using a 5-m-flight-path TOF spectrometer; a typical target had a neutron thickness from 8 to 10 keV for Esub(p) = 2.25.MeV. Spectra were analyzed using the unfolding code TINA; standard peak shapes were obtained from codes LAGUE and LAPA. Results obtained will be presented.
The /sup 40/Ca(p,n)/sup 40/Sc reaction was studied at 134 MeV. Neutron energy spectra were measured by the time-of-flight technique with resolutions of 220 keV at angles from 0"0 to 41"0 and 415 keV out to 62"0. The 2"-,3"-,4"-,5"- band of states based on the (f/sub 7/2/,d/sub 3/2//sup -1/) 1p1h structure was observed at low excitation energies, in good agreement with known analog states in /sup 40/Ca and /sup 40/K. The shapes of the cross-section and analyzing-power angular distributions are in good agreement with distorted-wave impulse-approximation calculations using simple 1p1h (Tamm-Dancoff approximation) shell-model wave functions. A relatively strong transition to a state at E/sub x/ = 2.3 MeV with L = 3 is identified tentatively as a 4"- state with the predominant 1p1h structure (1f/sub 7/2/,2s/sub 1/2//sup -1/).
The enhancement of positive secondary ion yields of silicon due to the presence of oxygen has been investigated quantitatively by low-energy (5 keV) oxygen implantation. Implantation and sputter profiling with 9 keV In/sup +/ were performed in the same ion microprobe instrument. Depth profiles of substrate and implanted oxygen atoms were measured for fluences ranging from 5x10/sup 15/ to 4x10/sup 16/ O-atoms/cm/sup 2/. The oxygen concentration, c(O), in the sample was deduced from the implanted fluence and the range distribution in the Gaussian approximation. It was found that the oxygen-enhanced Si/sup +/ intensity is proportional to c(O)sup(x) (with x=1.4) in the concentration regime, 1.5<=c(O)<=30 at%. The O/sup +/ intensity shows a similar dependence for c(O)> or approx.20 at.%.
The main challenges for PMOS ultra shallow junction formation remain the transient enhanced diffusion (TED) and the solid solubility limit of boron in silicon. It has been demonstrated that low energy boron implantation and spike annealing are key in meeting the 90nm technology node ITRS requirements. To meet the 65nm technology requirements many studies have used fluorine co-implantation with boron and Si"+ or Ge"+ pre-amorphization (PAI) and spike annealing. Although using BF_2"+ can be attractive for its high throughput, self-amorphization and the presence of fluorine, many studies have shown that the fluorine successfully reduce TED, its energy needs to be well optimized with respect to the boron's, therefore BF_2"+ does not present the right fluorine/boron energy ratio for the optimum junction formation. In this work we optimize the fluorine energy for boron energies down to 200eV. We show the dependence of optimized junction on Ge"+ energies of 2keV and ...
Coded imaging techniques using thick, micro-Fresnel zone plates as coded apertures have been used to image x-ray emissions (2-20 keV) and 3.5 MeV Alpha particle emissions from laser driven micro-implosions. Image resolution in these experiments was 3-8 ..mu..m. Extension of this coded imaging capability to higher energy x-rays (approx. 100 keV) and more penetrating charged particles (e.g. approx. 15 MeV protons) requires the fabrication of very thick (50-200 ..mu..m), high aspect ratio (10:1), gold Fresnel zone plates with narrow linewidths (5-25 ..mu..m) for use as coded aperatures. A reactive ion etch technique in oxygen has been used to produce thick zone plate patterns in polymer films. The polymer patterns serve as electroplating molds for the subsequent fabrication of the free-standing gold zone plate structures.
Coded imaging techniques using thick, micro-Fresnel zone plates as coded apertures have been used to image x-ray emission (2--20 keV) and 3.5 MeV Alpha particle emissions from laser driven micro-implosions. Image resolution in these experiments was 3--8 ..mu..m. Extension of this coded imaging capability to higher energy x rays (approx.100 KeV) and more penetrating charged particles (e.g., approx.15 MeV protons) requires the fabrication of very thick (50--200 ..mu..m), high aspect ratio (10:1), gold Fresnel zone plates with narrow linewidths (5--25 ..mu..m) for use as coded apertures. A reactive ion etch technique in oxygen has been used to produce thick zone plate patterns in polymer films. The polymer patterns serve as electroplating molds for the subsequent fabrication of the free-standing gold zone plate structures.
Microfabrication processes for Y-Ba-Cu-O films have been investigated, using ion-beam techniques. High-T_c superconducting lines as narrow as 0.8 #mu#m have been fabricated from epitaxial YBa_2Cu_3O_7 _- _y films by Ar ion-beam etching (IBE), combined with focused ion-beam (FIB) lithography. The resulting lines, 1.3 #mu#m wide and 2 mm long, showed a zero resistance temperature of 81 K and a critical current density of 1.9 x 10"4 A/cm"2 at 77.3 K. Maskless etching was carried out using 130-keV au"+ focused ion-beam (FIB) with a 0.1-#mu#m-diameter beam. A 50-nm-thick film was patterned into 0.3-#mu#m-wide lines at a dose of 5 x "1"6 ions/cm"2. In comparison with Ar IBE, Cl_2 reactive ion-beam etching (RIBE) exhibited an enhancement effect in sputtering yield. Ion implantation with 300-keV Si"+ "+ FIB also indicated the possibility to produce submicrometer patterns by selectively modifying film properties from superconductive to normal or ...
The effect of the #+-# 0.75 T external magnetic field on the K_#alpha#_1, K_#alpha#_2, K_#beta#_'_1 and K_#beta#_'_2 x-ray production cross sections and radiative vacancy transfer probabilities from K-shell to L2 and L3 subshells and M-shell for ferromagnetic Nd, Gd and Dy and paramagnetic Eu and Ho have been investigated, using the 59.5 keV incident photons. K-shell fluorescence yields and K x-ray intensity ratios for these elements have been determined in the external magnetic field also. The K x-rays from different targets were detected using a high-resolution Si(Li) semiconductor detector. For B = 0, the present experimental results were compared with the experimental and theoretical data in the literature. The results show that K-shell fluorescence parameters such as photoionization cross section, fluorescence yield, radiation rates, vacancy transfer probabilities and spectral linewidth can change owing to the applied magnetic field. (authors)
The fission cross section of /SUP 242m/ Am has been measured from 0.005 eV to 20 MeV using time-of-flight techniques at the Oak Ridge Electron Linear Accelerator. A hemispherical plate fission ionization chamber with five pairs of plates contained three deposits totaling 507 ..mu..g of /SUP 242m/ Am, one deposit of 168 ..mu..g /sup 235/U, and a ''weightless'' deposit of /sup 252/Cf, which served as a monitor of chamber performance. The fission of /sup 235/U, served as the cross-section standard for energies above 101 keV while /sup 6/Li(n,..cap alpha..), normalized to /sup 235/U fission in the 7.8- to 11.0-eV interval, served as a shape standard below 101 keV. Approximately 360 h of data were obtained at a flight path distance of 9.1 m, primarily with 40-ns bursts. Particular attention was paid to correction of backgrounds, especially inscattered-neutron-induced events. The fission resonance integral was ...
The fission cross section of /SUP 242m/ Am has been measured from 0.005 eV to 20 MeV using time-of-flight techniques at the Oak Ridge Electron Linear Accelerator. A hemispherical plate fission ionization chamber with five pairs of plates contained three deposits totaling 507 #mu#g of /SUP 242m/ Am, one deposit of 168 #mu#g "2"3"5U, and a ''weightless'' deposit of "2"5"2Cf, which served as a monitor of chamber performance. The fission of "2"3"5U, served as the cross-section standard for energies above 101 keV while "6Li(n,#alpha#), normalized to "2"3"5U fission in the 7.8- to 11.0-eV interval, served as a shape standard below 101 keV. Approximately 360 h of data were obtained at a flight path distance of 9.1 m, primarily with 40-ns bursts. Particular attention was paid to correction of backgrounds, especially inscattered-neutron-induced events. The fission resonance integral was found to be 1800 + or - 65 b.
The measurements of the L X-ray intensity ratio I(L?)/I(L?), I(L?)/I(L?), I(L?)/I(L?), I(L?)/I(L?) and I(L?)/I(L?) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV ?-rays from a filtered radioisotope 241Am was used, and by the radioactive decay of 160Tb, 160Er, 173Lu, 182Re, 201Tl, 203Pb and 207Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L?/L?), I(L?/L?), I(L?/L?), I(L?/L?) and I(L?/L?) intensity ratios were calculated using theoretically tabulated values of subshell photoionization cross-section, fluorescence yield, fractional X-ray emission rates, Coster-Kronig transition probabilities. It was observed that present values agree with previous theoretical and other available experimental results.
The L shell fluorescence cross-sections of the elements in range 45Z50 have been determined at 8keV using Synchrotron radiation. The individual L X-ray photons, Ll, La, LbI, LbII, LgI and LgII produced in the target were measured with high resolution Si(Li) detector. The experimental set-up provided a low background by using linearly polarized monoenergetic photon beam, improving the signal-to-noise ratio. The experimental cross-sections obtained in this work were compared with available experimental data from Scofield [1,2] Krause [3,4] and Scofield and Puri et al. [5,6]. These experimental values closely agree with the theoretical values calculated using Scofield and Krause data, except for the case of Lg, where values measured of this work are slighter higher.
Thin Fe and Ta layers of 30-45 nm thickness, deposited via magnetron sputtering on Si (1 0 0) substrates, were bombarded at room temperature with 100 keV Ar{sup 1+} or Ar{sup 8+} or with 250 keV Xe{sup 1+} or Xe{sup 19+} ions in order to test the influence of the ion charge state on the surface sputtering and interface mixing. The samples were characterized by means of Rutherford backscattering at 0.9-3.0 MeV {alpha}-particle energy, time-of-flight elastic recoil detection analysis with a 53 MeV {sup 127}I{sup 10+} beam and atomic force microscopy. No influence of the charge state on the sputtering and athermal mixing rate was observed in the case of the Ta/Si system. However, in the case of the Fe/Si system, the ion charge was observed to have an influence on the mixing rate.
The Micro-X instrument is a rocket borne, X-ray imaging spectrometer planned for launch in October 2011. An array of 128 Transition Edge Sensors (TESs) on a 600 micron pitch will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. X-rays will be focused onto the TES array by a conically approximated Wolter optic with an effective area of 300 cm^2 giving the instrument a field of view of 11.8 arcmin. This performance will constitute a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat bath, and will be read out by a SQUID time division multiplexer. The first flight of the Micro-X instrument will observe the Puppis A supernova remnant. Future targets include the core of ...
For an assessment of the future US spallation neutron source (SNS) target performance, radiation induced hardening and microstructural evolution were investigated as a function of ion dose for EC316LN stainless steel. Irradiation was carried out using 3.5 MeV Fe{sup +}, 360 keV He{sup +}, and 180 keV H{sup +} simultaneous ion-beams at 200 deg. C to simulate the damage, He and H production in the SNS target vessel wall. At low dose (< 1 dpa), the predominant defects were black dots whose number density saturated rapidly within a few dpa. This was followed by the evolution of interstitial loops whose number density saturated below 15 dpa. Although He-bubbles were not visible, severely scalloped loops suggested that the implanted He/H atoms existed in the form of small clusters. Comparison with reported neutron irradiation data showed that hardening and ductility loss occurred mostly in the black dot regime (< 1 dpa), but that good ...
For an assessment of the future US spallation neutron source (SNS) target performance, radiation induced hardening and microstructural evolution were investigated as a function of ion dose for EC316LN stainless steel. Irradiation was carried out using 3.5 MeV Fe"+, 360 keV He"+, and 180 keV H"+ simultaneous ion-beams at 200 deg. C to simulate the damage, He and H production in the SNS target vessel wall. At low dose (< 1 dpa), the predominant defects were black dots whose number density saturated rapidly within a few dpa. This was followed by the evolution of interstitial loops whose number density saturated below 15 dpa. Although He-bubbles were not visible, severely scalloped loops suggested that the implanted He/H atoms existed in the form of small clusters. Comparison with reported neutron irradiation data showed that hardening and ductility loss occurred mostly in the black dot regime (< 1 dpa), but that good ductility (>20% ...
The energy resolution of small NaI(Tl), CsI(Tl), BGO, GSO, YAP and LSO crystals has been studied using 16 mm diameter large area avalanche photodiodes (LAAPD) and a 52 mm diameter photomultiplier. The best result of 4.8% for 662 keV #gamma#-rays from a "1"3"7Cs source was obtained with a 9 mm in diameter by 9 mm high CsI(Tl) scintillator coupled to an LAAPD. Measuring the number of primary electron-hole pairs produced in the LAAPD and photoelectrons in the photomultiplier, as well as the noise contribution of the LAAPD, allowed a quantitative discussion of the results. The energy resolutions measured with LAAPDs are comparable to, or significantly better (at certain emission wavelengths) than, those obtained with the photomultiplier. At energies above 100 keV the energy resolution measured with the majority of crystals and the LAAPD was weakly affected by the photodiode noise contribution. The advantages and limitations of LAAPDs in energy ...
In this paper, we study the effect of the Ge{sup +} preamorphization dose on boron diffusion and on the thermal evolution of end of range (EOR) defects during annealing. Amorphizations were carried out by implanting Ge{sup +} at 150 keV to doses ranging from 1x10{sup 15} to 8x10{sup 15} ions/cm{sup 2}. Boron was subsequently implanted at 3 keV with a dose of 1x10{sup 14} ions/cm{sup 2}. Rapid thermal annealing (RTA) was performed for various time/temperature combinations in nitrogen ambient. Secondary ion mass spectroscopy (SIMS) and transmission electron microscopy (TEM) were used to study boron diffusion and defect evolution, respectively. We have found that after a given annealing, both the defect size and boron diffusivity are independent on the Ge ion dose. Increasing this dose only results in an increase of the defect density. These results are discussed and definitely show that EOR defects are involved in a quasi-conservative Ostwald ...
In this paper, we study the effect of the Ge"+ preamorphization dose on boron diffusion and on the thermal evolution of end of range (EOR) defects during annealing. Amorphizations were carried out by implanting Ge"+ at 150 keV to doses ranging from 1x10"1"5 to 8x10"1"5 ions/cm"2. Boron was subsequently implanted at 3 keV with a dose of 1x10"1"4 ions/cm"2. Rapid thermal annealing (RTA) was performed for various time/temperature combinations in nitrogen ambient. Secondary ion mass spectroscopy (SIMS) and transmission electron microscopy (TEM) were used to study boron diffusion and defect evolution, respectively. We have found that after a given annealing, both the defect size and boron diffusivity are independent on the Ge ion dose. Increasing this dose only results in an increase of the defect density. These results are discussed and definitely show that EOR defects are involved in a quasi-conservative Ostwald ripening process during annealing. ...
Technologies producing high power negative ion beams have been highly developed in these years at JAERI for use in neutral beam injectors for heating the thermonuclear fusion plasmas. At present, it is possible to produce multi-ampere H-/D- ion beams quasi-continuously at energies more than a few hundred keV with a good beam optics of beamlet divergence of a few milli-radian. Based on these technologies, two R and D projects have been initiated; one is to develop a 22A/500keV/10s D- ion source for the neutral beam injector for JT-60U, and the other is to develop a 1A/1MeV/60s H- ion source to demonstrate high current negative ion acceleration up to the energy of 1MeV, the energy required for the neutral beam injector for International Thermonuclear Experimental Reactor (ITER). (author).
A cell calculation code SLAROM-UF has been developed for fast reactor analyses to produce effective cross sections with high accuracy in practical computing time, taking full advantage of fine and ultra-fine group calculation schemes. The fine group calculation covers the whole energy range in a maximum of 900-group structure. The structure is finer above 52.5 keV with a minimum lethargy width of 0.008. The ultra-fine group calculation solves the slowing down equation below 52.5 keV to treat resonance structures directly and precisely including resonance interference effects. Effective cross sections obtained in the two calculations are combined to produce effective cross sections over the entire energy range. Calculation accuracy and improvements from conventional 70-group cell calculation results were investigated through comparisons with reference values obtained with continuous energy Monte Carlo calculations. It was confirmed that ...
A C{sub 60} {sup +} primary ion source has been coupled to an ion microscope secondary ion mass spectrometry (SIMS) instrument to examine sputtering of silicon with an emphasis on possible application of C{sub 60} {sup +} depth profiling for high depth resolution SIMS analysis of silicon semiconductor materials. Unexpectedly, C{sub 60} {sup +} SIMS depth profiling of silicon was found to be complicated by the deposition of an amorphous carbon layer which buries the silicon substrate. Sputtering of the silicon was observed only at the highest accessible beam energies (14.5 keV impact) or by using oxygen backfilling. C{sub 60} {sup +} SIMS depth profiling of As delta-doped test samples at 14.5 keV demonstrated a substantial (factor of 5) degradation in depth resolution compared to Cs{sup +} SIMS depth profiling. This degradation is thought to result from the formation of an unusual platelet-like grain structure on the SIMS crater bottoms. Other ...
Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO_2 substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio I(111)/I(200) reaches its maximum value indicating a strong left-angle 111 right-angle texture, while the impurity concentration and resisitivity are minimum. The correlation between the structural, compositional and electrical properties ...
Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO{sub 2} substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio {ital I}(111)/{ital I}(200) reaches its maximum value indicating a strong {l angle}111{r angle} texture, while the impurity concentration and resisitivity are minimum. The correlation between the structural, compositional and ...
Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO{sub 2} substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio {ital I}(111)/{ital I}(200) reaches its maximum value indicating a strong {l angle}111{r angle} texture, while the impurity concentration and resisitivity are minimum. The correlation between the structural, compositional and ...
A low-molybdenum austenitic stainless steel (UNS S30100) has been surface implanted with molybdenum ions, using various doses of 50 keV and 140 keV ions at room temperature. It is found that in aqueous sulphate/chloride solutions similar to the constitution of sea-waters the implantation does not affect the potentiostatically-determined critical pitting potential, but does change the density and morphology of corrosion pits. Pitting initiation after the addition of chloride at a fixed potential indicates little change in the time for measurable current increase, but the rate of increase of the current is much lower for implanted material. Detailed examination using optical microscopy, scanning electron microscopy, transmission electron microscopy and selected area diffraction suggests that the pits produced in implanted material are hemispherical with smooth covers of unattacked alloy. The use of half-implanted samples demonstrates that ...
A low-molybdenum austenitic stainless steel (UNS S30100) has been surface implanted with molybdenum ions, using various doses of 50 keV and 140 keV ions at room temperature. It is found that in aqueous sulphate/chloride solutions similar to the constitution of sea-waters the implantation does not affect the potentiostatically-determined critical pitting potential, but does change the density and morphology of corrosion pits. Pitting initiation after the addition of chloride at a fixed potential indicates little change in the time for measurable current increase, but the rate of increase of the current is much lower for implanted material. Detailed examination using optical microscopy, scanning electron microscopy, transmission electron microscopy and selected area diffraction suggests that the pits produced in implanted material are hemispherical with smooth covers of unattacked alloy. The use of half-implanted samples demonstrates that ...
Two measurement methods to determine the rate of neutral free radical production by the photo-deionization of negative ion beams (PDINIB) are introduced. These methods, namely, photoelectron-current measurement by low-frequency electro-modulation probe (PMMP) and measurement of decrease in the negative-ion beam current (DNIC) were employed to evaluate the production rate in a trial surface-processing apparatus developed in the author's laboratory utilizing a steady-flux refined beam of neutral free radicals (RBNR) produced by the PDINIB procedure. A {sup 63}Cu{sup -} negative ion beam of kinetic energy E{sub i} varied up to 15 keV was irradiated with a 514.5 nm visible light beam from a 25 W CW Ar{sup +} ion laser. The detection limit of the production rate by the PMMP setup was as high as 6 x 10{sup 9} s{sup -1} under the condition that E{sub i}=15 keV, the negative-ion beam current I{sub i}=4 {mu}A and the laser power P=6 W. The DNIC ...
Lanthanum halide (LaBr_3:Ce) scintillators offer significantly better resolution (< 3% at 662 keV) relative to NaI(Tl) and have recently become commercially available in sizes large enough for the handheld, Radio-Isotope Identification Device (RIID) market. Drawbacks to lanthanum halide detectors, however, include internal radioactivity contributing to spectral counts, and a low-energy response which can cause detector resolution to be worse than that of NaI(Tl) below 100 keV. To study the potential of this new material for RIIDs we performed a series of measurements comparing a 1.5 x 1.5-inch LaBr_3:Ce detector with an Exploranium GR-135 RIID, which contains a 1.5 x 2.2-inch NaI(Tl) detector. Measurements were taken for short timeframes, as typifies RIID usage. Measurements included examples of naturally occurring radioactive material (NORM), typically found in cargo, and special nuclear materials. Some measurements were non-contact, ...
CEA-Valduc produces some radioactive waste (mainly alpha emitters). Legislation requires producers to sort their waste by activity and type of isotopes, and to package them in order to forward them to the appropriate reprocessing or storage facility. Our lab LMDE (laboratory for measurements on nuclear wastes and valuation) is in charge of the characterization of the majority of waste produced by CEA-Valduc. Among non-destructive methods to characterize a radioactive object, gamma-spectroscopy is one of the most efficient. We present to this conference the method we use to characterize nuclear waste and the system we developed to characterize our germanium detectors. The goal of this system is to obtain reliable numerical models of our detectors and calculate their efficiency curves. Measurements are necessary to checks models and improve them. These measurements are made on a bench using pinpoint sources ("1"3"3Ba, "1"5"2Eu) from 60 keV to 1500 ...
Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument designed to measure polarization from astrophysical objects in the 30-100 keV range, under development by an international collaboration with members from United States, Japan, Sweden and France. To examine PoGO's capability, a beam test of a simplified prototype detector array was conducted at the Argonne National Laboratory Advanced Photon Source. The detector array consisted of seven plastic scintillators, and was irradiated by polarized photon beams at 60, 73, and 83 keV. The data showed a clear polarization signal, with a measured modulation factor of $0.42 \\pm 0.01$. This was successfully reproduced at the 10% level by the computer simulation package Geant4 after modifications to its implementation of ...
This paper reports measurements of absolute differential cross sections for the direct scattering of oxygen atoms by He, Ne, Ar, Kr, Xe, H_2, N_2, O_2, CO, CO_2, H_2O, SO_2, NH_3, CH_4, CF_4, and SF_6 targets. The measured cross sections include contributions from all elastic and inelastic processes that result in a fast neutral oxygen atom product. Cross sections are presented for 0.5- and 1.5-keV projectile energies over the laboratory angular range 0.2 degree endash 5 degree. When compared in the center-of-mass reference frame, these cross sections exhibit a high degree of similarity in both amplitude and angular dependence. The cross sections for N_2, CO, CO_2, and H_2O are inverted using a partial-wave analysis to yield empirical interaction potentials, which can then be used to extrapolate the measurements down to lower energies. Using these potentials, cross sections are evaluated at 0.1 keV. copyright 1996 The American Physical Society.
Recent X-ray and radio observations have identified a transient low-mass X-ray binary (LMXB) located only 0.1 pc in projection from the Galactic center, CXOGC J174540.0-290031. In this paper, we report the detailed analysis of X-ray and infrared observations of the transient and its surroundings. Chandra bservations detect the source at a flux of F_X = 2e-12 erg cm^-2 s^-1 (2-8 keV). After accounting for absorption both in the interstellar medium and in material local to the source, the implied luminosity of the source is only L_X = 4e34 erg/s (2-8 keV; D=8 kpc). However, the diffuse X-ray emission near the source also brightened by a factor of 2. The enhanced diffuse X-ray emission lies on top of a known ridge of dust and ionized gas that is visible infrared images. We interpret the X-ray emission as scattered flux from the outburst, and determine that the peak luminosity of CXOGC J174540.0-290031 was >2e36 erg/s. We suggest that the ...
These experiments were performed on the Isocele separator, on-line with the Orsay synchrocyclotron; thulium isotopes were produced by bombarding natural erbium targets with 150nA beam of 157MeV protons. Two Ge(Li) detectors, with resolution of 2.3 and 2.5keV at 1332keV used for #gamma#-ray measurements; conversion electron spectra were measured using a Si(Li) detector. #gamma# spectra, #gamma#-#gamma# coincidence and conversion electron measurements were sufficient to build the flow energy level schemes of the transitional "1"5"8Er and "1"5"6Er nuclei. On both nuclei several quasi rotational bands have been identified. These results are compared with other even erbium isotopes and with the neighboring N=88 and 90 isotones. Comparisons with predictions issued from some classical models are also performed: "1"5"8Er appears as a deformed nucleus very similar to "1"6"0Er and "1"6"2Er; on the other hand "1"5"6Er seems to be a soft vibrational ...
X-ray fluorescence analysis was used to determine the zinc content of the ''Perilacin'' powder and the ZnO content of the ''Epiderman-pix'' powder. The characteristic Ksub(#alpha#) line of zinc was excited using a "1"4"7Pm/Mo source (10"7 s"-"1) and the molybdenum Ksub(#alpha#) line (17.47 keV). 4 to 5% Zn and 45 to 49% ZnO were determined with a NaI(Tl) scintillation detector. The radiation intensity was found to decrease with particle size. (M.K.).
The penetration depth and concentration distribution for vanadium ions with low energy implanted into the dry peanut seeds is determined by scanning electron microscope and X-ray energy dispersion spectrometer. The results show that the depth-concentration distribution is a Gaussian distribution with a long tail and the maximum penetration depth is about 13.6 #mu#m for V"+ with 200 keV in cotyledon of the peanut. The experimental result of the implanted V"+ range in the peanut seeds is compared with the calculating value of the TRIM95
Recent results of the experiments at GOL-3 facility are presented. Plasma with a density of 1014...1016 cm-3 is confined in a 12-meter-long solenoid, which comprises 55 corrugation cells with mirror ratio Bmax/B min=4.8/3.2 T. The plasma is heated up to 2...4 keV temperature by a high power relativistic electron beam (?1 MeV, ? 330 kA, ?8?s, ?120 kJ) injected through one of the ends. Mechanism of experimentally observed fast ion heating, issued of plasma stability and confinement are discussed.
We have synthesized ozone by irradiating thin solid films of oxygen and oxygen-water mixtures with 100 keV protons, motivated by recent reports of condensed O_3 on icy satellites in the outer Solar system. We measured the depth of the Hartley absorption band in the ultraviolet by reflectance spectroscopy and used it to quantify the column density of ozone. We analyzed the results using a three-component (O, O_2 and O_3) model that successfully explains the fluence dependence of ozone production.
Theoretical analysis of the electric field bifurcation is made for the LHD plasma. For given shapes of plasma profiles, a region of bifurcation is obtained in a space of the plasma parameters. In this region of plasma parameters, the electric field domain interface is predicted to appear in the plasma column. The reduction of turbulent transport is expected to occur in the vicinity of the interface, inducing a internal transport barrier. Within this simple model, the plasma with internal barriers is predicted to be realized for the parameters of T{sub e}(0) {approx} 2 keV and n(0) {approx_equal} 10{sup 18} m{sup -3}. (author)
The K-shell X-ray intensity ratios for W, Au, Tl, Pb, Bi, Th and U were measured at a photon incident energy of 121.9 keV from "5"7Co radionuclide. A comparison between the experimental results and the theoretically calculated values shows that the experimental results are, in general, higher than the theoretical values. The measured intensities are regarded to be reported for the first time. (author) 9 refs.; 1 tab.
Recent studies have provided data that make it possible to estimate the efficiency and cost of future beamlines using a chemical oxygen-iodine laser as a neutralizer. These studies indicate that a 400-keV neutral deuterium beam of more than 20 A will operate at an efficiency >60%, with the capital cost of the neutralizer at less than $2/W of neutral beam output. Beamlines of lower current and less energy will operate at poorer efficiencies and higher neutralizer costs per watt of neutral beam. These are estimates. As they are very sensitive to changes in the assumptions from which they were derived, they must be used with some caution. Additional studies are expected to provide more reliable estimates.
In situ Auger sputter depth profiles of saturation implants of 3 keV N/sub 2//sup +/ in silicon at room temperature exhibit a sharp peak in the nitrogen concentration in the outermost layers, followed by a monotonic decrease. No broad plateau was observed. The energy of the Auger line corresponding to the Si(2p) core electron excitation, monitored throughout the profiling, exhibits a chemical shift of up to 7 eV at the surface peak concentration. Inert gas ion post-bombardment of unsaturated implants significantly modifies the profile, and supports the suggestion that the surface peak arises through radiation enhanced diffusion of implanted atoms.
Energy level schemes are derived from gamma spectroscopy of several medium-mass deformed nuclei by studying the decay or proton and #alpha# nuclear spectroscopic data. Some new isomeric studies are established among which is the 31 y "1"7"8Hf isomeric state for which Isup(#pi#), K was determined to be 16"+, 16. A four quasi-particle configuration was assigned to this state at 2447.5 +- 2.5 KeV. Atomic masses have been calculated from various measurements and, on the basis of mass formulae extrapolated to neighboring mass regions.
Direct determination of "2"3"2U and its decay products in animal tissues appears to be feasible using an intrinsic Ge(Li) diode detector (for energies of 5-100 keV) and a NaI(Tl) anticoincidence-shielded Ge(Li) diode for higher-energy gamma photons. The detection sensitivity for "2"3"2U and "2"2"8Th is 0.03 and 0.01 nCi, respectively, using a 300-min counting time.
A helium-3 proportional detector was equipped with the experiment of Liaw-type electrolytic cell contained eutectic LiCl-KCl molten salt saturated by LiD electrolytic to collect the informations of the rate and the energy distribution of possible neutron produced during the electrolysis processes. For long time monitoring, the significant reproducible neutron bursts appeared at several runs of cells during electrolytic processing. The neutron counting rate increased about a factor of two above the level of the background measurement. The pulse height signals were verified of neutron energy ranging from thermal up to 350 keV. (author).
In order to obtain the resonance parameters in a single energy range and the corresponding covariance matrix, a reevaluation of 239Pu was performed with the code SAMMY. The most recent experimental data were analyzed or reanalyzed in the energy range thermal to 2.5 keV. The normalization of the fission cross section data was reconsidered by taking into account the most recent measurements of Weston et al. and Wagemans et al. A full resonance parameter covariance matrix was generated. The method used to obtain realistic uncertainties on the average cross section calculated by SAMMY or other processing codes was examined.
Q/sub ..beta..-values are determined for 18 nuclei (Zr-, Nb-, Mo-, Tc-, Ru- and Rh-nuclides) with mass numbers 101 less than or equal toA less than or equal to106 and A=109 from measurements of beta decay energies which were carried out at the LOHENGRIN mass separator at the Institut Laue-Langevin in Grenoble (France). The given Q/sub ..beta..-values between 2 and 8 MeV show errors of about 1.5% (with the exception of /sup 103/Zr and /sup 105/Nb resp. and /sup 103/Tc for which larger errors result due to statistical resp. systematic reasons): /sup 101/Zr 5500+-70, /sup 101/Nb 4580+-45, /sup 102/Zr 4670+-40, /sup 102/Nb 7230+-70, /sup 103/Zr 6790+-240, /sup 103/ 5740+-70, /sup 103/Mo 3575+-80, /sup 103/Tc 2585+-70, /sup 104/Nb 8250+-130, /sup 104/Mo 2180+-40, /sup 104/Tc 5520+-100, /sup 105/Nb 6570+-150, /sup 105/Mo 4885+-80, /sup 105/Tc 3750+-60, /sup 106/Mo 3515+-45, /sup 106/Tc 6540+-70, /sup 109/Ru 4150+-80, /sup 109/Rh 2550+-50 (all values in keV). For the ...
Q_#beta#-values are determined for 18 nuclei (Zr-, Nb-, Mo-, Tc-, Ru- and Rh-nuclides) with mass numbers 101 #<=# A #<=# 106 and A=109 from measurements of beta decay energies which were carried out at the LOHENGRIN mass separator at the Institut Laue-Langevin in Grenoble (France). The given Q_#beta#-values between 2 and 8 MeV show errors of about 1.5% (with the exception of "1"0"3Zr and "1"0"5Nb resp. and "1"0"3Tc for which larger errors result due to statistical resp. systematic reasons): "1"0"1Zr 5500#+-#70, "1"0"1Nb 4580#+-#45, "1"0"2Zr 4670#+-#40, "1"0"2Nb 7230#+-#70, "1"0"3Zr 6790#+-#240, "1"0"3 5740#+-#70, "1"0"3Mo 3575#+-#80, "1"0"3Tc 2585#+-#70, "1"0"4Nb 8250#+-#130, "1"0"4Mo 2180#+-#40, "1"0"4Tc 5520#+-#100, "1"0"5Nb 6570#+-#150, "1"0"5Mo 4885#+-#80, "1"0"5Tc 3750#+-#60, "1"0"6Mo 3515#+-#45, "1"0"6Tc 6540#+-#70, "1"0"9Ru 4150#+-#80, "1"0"9Rh 2550#+-#50 (all values in keV). For the measurement of beta-gamma coincidences a #DELTA#E/E-plastic ...
LUCIFER (Low-background Underground Cryogenic Installation For Elusive Rates) is a new project for the study of neutrinoless Double Beta Decay, based on the technology of scintillating bolometers. These devices promise a very efficient rejection of the alpha background, opening the way to a virtual background-free experiment if candidates with a transition energy higher than 2615 keV are investigated. The baseline candidate for LUCIFER is 82Se. This isotope will be embedded in ZnSe crystals grown with enriched selenium and operated as scintillating bolometers in a low-radioactivity underground dilution refrigerator. In this paper, the LUCIFER concept will be introduced. The sensitivity and the very promising prospects related to this project will be discussed.
The additional error in measurement of the thickness of Kh18N10T steel for possible changes in composition with an energy of the photons of ionizing radiation of 10-80 keV was evaluated. The desirability of use of a type REIS-I x-ray emitter in measurement of the thickness of steel up to 1 mm is shown. The instrument provides measurement of the thickness of steel in the 0.1-1.0 mm range with a reproducibility of the results with an error not exceeding 0.5-1.0%. The measurement error with corrugations characteristic of bellows does not exceed 5%.
High-current implantation of Cu{sup {minus}} ions into silica glasses has been demonstrated using mA-class negative ion beams at 60 keV. Negative ion implantation has an advantage to alleviate specimen charging for insulating substrates and has attained high dose rates, up to 260 {micro}A/cm{sup 2}. Spherical Cu colloids form in the silica glasses without additional thermal annealing. Optical absorption and reflection of the implanted specimens vary with the current density, even at a fixed dose level. A beam-induced surface plasma may affect the high current implantation.
The feasibility of a high-energy electron cooling device has been studied through tests on a prototype of the electron device. The apparatus consists of a pulsed ((20-60) keV, 2#mu#s) electron gun, a drift region 1 m long and of a depressed collector for recovering the electron energy. Tests on beam optics and energy recovery have been performed, a high-energy recovery efficiency has been attained. Experimental results are discussed in this paper.
An electrostatic beam steering mechanism (ESM) has been designed and tested to deflect negative ion beams consisting of multi-beamlets. A steering angle of 10 mrad was obtained within the deviation of less than 1 mrad by biasing two electrodes at 0.5 kV and -0.75 kV for 120 keV H{sup -} ion beam. The current flowing to the positive electrode was no more than 10% of the beam current at a pressure of 2.8x10{sup -5} Torr. (author)
Delayed neutron energy spectra have been measured for six delay-time intervals following the fast fission of "2"3"8U nuclei. The delay-time intervals span the range 0.17 to 10.2 seconds following initial fission while the measured spectra span neutron energies from 10 keV to 4 MeV. The experiment was performed utilizing the UMass/Lowell 5.5 MV Van de Graff accelerator to produce fast neutrons for inducing fission in a "2"3"8U lined fission chamber. The fission fragments were flushed via a helium jet stream to a well-shielded counting room where they were deposited onto a moving tape (magnetic audio tape) and transferred to a beta-neutron time-of-flight spectrometer. By adjusting the tape speed, composite delayed neutron time-of-flight spectra were measured for several different delay-time intervals. These measurements involved beta-neutron coincidences with "6Li-loaded glass scintillators for neutron energies from 10 keV to 450 ...
Hardened CMOS/SOI 29101 microprocessor, elementary cells and transistor shave been irradiated at levels between 10 Mrad(SiO_2) and 1 Grad(SiO_2) ("6"0Co and 10 keV x-rays). SIMOX buried oxide behavior in the range of 100 Mrad(SiO_2) and a channel-stopped MOS/SOI structure avoiding lateral leakage current are presented. These two items indicate the feasibility of a CMOS/SOI technology operating in the hundred Mrad(SiO_2) range.
The development of high energy (> 150 keV) neutral beams for heating and fueling magnetic fusion devices depends on the ability to produce well-collimated negative ion beams. The double capture charge-exchange technique is a known, scalable method. In order to maximize the overall efficiency of the process and to achieve the desired beam characteristics, it is necessary to examine the optical qualities of the beams as well as the total efficiency of beam production. A combined modeling and experimental study of the angular scattering effects in negative ion formation and loss processes has therefore been undertaken.
CH Cygni is a symbiotic star consisting of an M giant and an accreting white dwarf, which is known to be a highly variable X-ray source with a complex, two-component, spectra. Here we report on two Suzaku observations of CH Cyg, taken in 2006 January and May, during which the system was seen to be in a soft X-ray bright, hard X-ray faint state. Based on the extraordinary strength of the 6.4 keV fluorescent Fe K-alpha line, we show that the hard X-rays observed with Suzaku are dominated by scattering.
The theoretical alignment limit for focused ion beam (FIB) implantation was deduced from the calculated resolution for the detection of an alignment mark. The alignment resolution varies with the signal to noise ratio and there is an optimum current which gives the best resolution. The alignment resolution epsilon/sub sigma/ is approximately 0.006 ..mu..m for a 160 keV Si/sup ++/ beam from our FIB implanter. The measured alignment error is approximately 0.06 ..mu..m and the main reason of this discrepancy is vibration. The ultimate limit on the alignment error can be reached through improvements in the implanter system.
We measured differential cross sections and vector analyzing powers for the "4"8Ca(d,n)"4"9Sc reaction at 79 MeV. An overall energy resolution of about 325 keV was achieved, and data were extracted for states up to 3.4 MeV of excitation. Both distorted-wave Born approximation and Johnson-Soper adiabatic approximation calculations were performed; in general, the Johnson-Soper adiabatic approximation calculations provide a better description of the data, and yield reasonable spectroscopic factors.
This paper deals with the externally coal-fired combined cycle (EFCC). A process simulation for different configurations of the EFCC-process is carried out as well as an investigation of the effect of the key parameters such as the gas turbine inlet temperature and the compressor intake airflow. The results show a promising potential of the efficiency. One component of this combined gas and steam turbine cycle is a high temperature heat exchanger that has to withstand the extrem chemical and thermal operating conditions. Fibre reinforced ceramics and combinations of them with monolithic ceramics seem to be the most promising materials for this application. A cost estimating of the EFCC-process shows that a competitive operation should be possible. (orig.) [Deutsch] Die Ergebnisse der Prozesssimulationen weisen ein vielversprechendes Wirkungsgradpotential des extern kohlebefeuerten Gasturbinenprozesses auf. Der fuer dieses neue Kraftwerkskonzept notwendige Hochtemperatur-Waermetauscher ...
The BMW four-cylinder two-valve engine was first launched in September 1987 as a 1.8 l engine and was described in detail in [1]. After initial optimisation for model year 94, four years later the engine has undergone a complete technical revision. From model year 98, the four-cylinder two-valve engine with appropriate exhaust emission technology will satisfy the EU3 class for exhaust emissions. (orig.) [Deutsch] Der BMW Vierzylinder-Zweiventilmotor wurde im September 1987 als 1,8-l-Motor erstmals vorgestellt und in [1] ausfuehrlich beschrieben. Nach einer ersten Optimierungsueberarbeitung zum Modelljahr 1994 wurde nun eine grundlegende technische Ueberarbeitung vorgenommen. Der Vierzylindermotor mit Zweiventiltechnik erfuellt als Antriebsaggregat in Verbindung mit einer entsprechenden Abgastechnik bereits ab Modelljahr 1998 die EU 3-Stufe fuer Abgasemissionen. (orig.)
Mutations in the mouse formin (Fmn) gene, formerly known as the limb deformity (ld) gene, give rise to recessively inherited limb deformities and renal malformations or aplasia. The Fmn gene encodes many differentially processed transcripts that are expressed in both adult and embryonic tissues. To study the genomic organization of the Fmn locus, we have used Fmn probes to isolate and characterize genomic clones spanning 500 kb. Our analysis of these clones shows that the Fmn gene is composed of at least 24 exons and spans 400 kb. We have identified two novel exons that are expressed in the developing embryonic limb bud as well as adult tissues such as brain and kidney. We have also used a microsatellite polymorphism from within the Fmn gene to map it genetically to a 2.2-cM interval between D2Mit58 and D2Mit103. 36 refs., 6 figs., 1 tab.
In this study, the bend properties of the single-crystalline molybdenum brazed by using Mo-40%Ru alloys containing boron of 1-6 mass%Ru alloy for the improvement of the joint strength was determined. (orig.) [Deutsch] Durchgefuehrt wurde die Herstellung von Verbindungen aus einkristallinem Molybdaen. Hierbei kamen Mo-40%Ru-Legierungen mit 1 bis 6 Gew.-% Bor als Lotmaterialien zum Einsatz. Festigkeit und Duktilitaet der Verbindungen wurden mittels 3-Punkt-Biegepruefung bei Raumtemperatur und unter fluessigem Stickstoff ermittelt. Die Bruchflaechen der Proben wurden mit Hilfe eines Rasterelektronenmikroskopes untersucht. Die Ergebnisse lassen sich wie folgt zusammenfassen: Der optimale Borgehalt bezueglich Festigkeit und Duktilitaet der geloeteten Verbindung liegt bei 2 Gew.-%. Die entsprechende Probe hat bei einem Biegewinkel von 100 bei Raumtemperatur nicht versagt. Auch unter fluessigem Stickstoff zeigte diese Probe eine Festigkeit in der ...
During the past 15 years, 60 straw-fuelled and 25 wood-fuelled district heating stations were commissioned in Denmark, as well as 6 biomass-fuelled heating power stations. All of these plants are equipped with high-pressure boilers, heat exchangers for district heating, and steam turbines with generators. Today, 5 percent of the total energy consumed is provided by biomass fuels. With the new taxes on carbon dioxide emissions and measures to promote renewable energy sources, a 15 percent share can be expected soon. (orig/SR) [Deutsch] In Daenemark wurden in den letzten 15 Jahren 60 strohbefeuerte und 25 holzbefeuerte Fernwaermewerke in Betrieb genommen. Dazu sind in den letzten Jahren 6 biomassebefeuerte Heizkraftwerke gekommen. Alle Anlagen haben Hochdruckkessel, Waermetauscher fuer Fernwaerme und Dampfturbinen mit Generatoren. Heute werden in Daenemark 15 Prozent des Energieverbrauchs mit Biomasse gedeckt. Durch Besteuerung der ...
The stirling cryocooler ILK 15 is a machine with simple drive concept. This machine works with a conventional built-in electric motor and crank drive and needs a power input of about 500 W. The refrigerating capacity is 15 W at 80 K with a cooldown time of 12 minutes. The cooler is somehow a replacement for the Gifford-McMahon cycle coolers, which are bigger and heavier. The Stirling cryocooler was designed to cool HTSC-components. (orig.) [Deutsch] Der Stirlingkuehler ILK 15 ist eine Kaeltemaschine mit einfachem Antriebskonzept. Die Maschine arbeitet mit einem konventionellen Elektroeinbaumotor und Kurbeltrieb. Sie benoetigt eine Antriebsleistung von 500 W und hat eine Kaelteleistung von 15 W bis 80 K und eine Einkuehlzeit von 12 Minuten. Die Maschine kann als Alternative zur wesentlich groesseren und schweren Gifford-McMahon-Maschine gesehen und bei der Kuehlung von HTSL-Komponenten eingesetzt werden. (orig.)
Efficiency of energy coversion of primary energy to an end use in industrial countries is about 30%. This is insufficient. Evaluating on basis of exergy efficiency becomes only about 15%. Usage of fuel cells give a great chance to improve efficiency. This concerns in particular to high temperature fuel cell systems SOFC and MCFC as well as their combination with heat pumps. [German] Die Effizienz der Energieversorgung in Industrielaendern ist energetisch bewertet mit rund 30 % unbefriedigend. Legt man den strengeren, energiewirtschaftlich treffenderen exergetischen Massstab an, halbiert sich dieser Wert sogar. Brennstoffzellen bieten durch ihren Einsatz Moeglichkeiten zur Effizienzerhoehung. Dies gilt insbesondere fuer die Hochtemperatursysteme SOFC und MCFC sowie deren Verbund mit Waermepumpen.
The MRI morphology in combined subacute degeneration has only rarely been reported. We describe two patients suffering from subacute combined degeneration of the spinal cord on the basis of a deficiency of vitamin B{sub 12}. In both patients characteristic hyperintense areas on T{sub 2}-weighted images in the posterior columns of the cervical and thoracic cord without contrast enhancement were demonstrated by MRI. (orig.) [Deutsch] Bisher liegen zur wenige Beschreibungen der MR-Morphologie bei funikulaerer Myelose vor. Wir beschreiben zwei Patienten mit den klinischen Zeichen einer funikulaeren Myelose auf der Basis eines Vitamin B{sub 12}-Mangels. Bei beiden konnten mit der MRT charakteristische Signalanhebungen im T{sub 2}-gewichteten Bild in den Hinterstraengen des zervikalen und thorakalen Rueckenmarks gezeigt werden. Eine Kontrastmittelaufnahme war nicht nachweisbar. (orig.)
The austenitic nitrided Cr-Mn steels CrMnN 1812, CrMnNMo 1714 and CrNiTi 1810 has been investigated in chloride nitric acid at temperature 20-60 C. The Potentials of pitting nucleation and the time for pitting initiation has been determinate by the hronoamperometric method. It was established that alloying only with nitrogen is not sufficient procedure for obtaining of resistive to localised corrosion steel structure. Of importance for the resistance to localised corrosion of Cr-Mn steels is alloying with molybdenum. (orig.) [Deutsch] Die austenitischen stickstoffhaltigen Cr-Mn Staehle CrMnN 1812, CrMnNMo 1714 und der klassische CrNiTi 1810 wurden in chloridhaltigen Salpetersaeureloesungen im Temperaturbereich 20-60 C untersucht. Durch die hronoamperometrische Methode wurden die Potentiale der Lochfrassbildung und die Zeit zur Initiierung der Lochfrasskorrosion bestimmt. Man stellte fest, dass das Legieren der Staehle nur mit Stickstoff eine nicht genuegende ...
The new multi-purpose oxygen cupola furnace is a coke-fired shaft furnace that is operated on pure oxygen. The top gas is recirculated, and the fumes are drawn off at temperatures ranging from 800 to 1 000 C. The furnace offers the possibility of melting down contaminated and zinc-bearing scrap without the occurrence of any environment-polluting gas emissions. The absence of nitrogen ballast permits a high energy efficiency. (orig.) [Deutsch] Der neue Mehrzweck-Sauerstoff-Kupolofen ist ein koksbeheizter Schachtofen, der mit reinem Sauerstoff betrieben wird. Das Gichtgas wird im Kreislauf gefuehrt, und das Abgas wird aus einem Bereich mit Temperaturen von 800 bis 1 000 C abgefuehrt. Der Ofen bietet die Moeglichkeit, verunreinigte und zinkhaltige Schrotte einzuschmelzen, ohne dass umweltbelastende Gasemissionen auftreten. Der fehlende Stickstoffbalast bewirkt einen hohen energetischen Wirkungsgrad. (orig.)
Melting in a cokeless cupola furnace fuelled with natural gas is a novel, energy-saving and environment-friendly process. In order to be able to monitor the processes inside the furnace with detailed mass and heat balances, an experimental furnace with an efficient measuring system was constructed in the framework of a research project financed by the BMFT and Messrs. Eisenwerke Dueker GmbH und Co. KG, Laufach, Germany. (orig./HS) [Deutsch] Das Schmelzen im kokslosen erdgasgefeuerten Kupolofen ist ein neues, energiesparendes und umweltfreundliches Verfahren. Um die Vorgaenge im Ofen mit umfassenden Stoff- und Waermebilanzen erfassen zu koennen, ist im Rahmen eines vom BMFT und der Firma Eisenwerke Dueker GmbH und Co. KG, Laufach, finanzierten Forschungsvorhabens, ein Versuchsofen mit umfangreicher Messeinrichtung gebaut worden. (orig./HS)
The analyses were carried out using real climate data for the years 1987 and 1989. The course of the indoor climate for year-round free ventilation with a constant flow volume is discussed. Numerous diagrams inform on ambient temperature, water vapour content, the condition of space air, and temperature drops below dew point. For the event of heating of the central part of the church, space air condition, the annual air humidification requirement, and the temperature field in this part of the building are described. (MSK) [Deutsch] Die Untersuchungen wurden mit aktuellen Klimadaten fuer die Jahre 1987 und 1989 durchgefuehrt. Der Verlauf des Raumklimas bei ganzjaehrig freier Klimatisierung mit konstantem Foerderstrom wird erlaeutert. Dabei wird die Raumlufttemperatur, der Wasserdampfgehalt, der Raumluftzustand sowie die Taupunktunterschreitung in zahlreichen Diagrammen aufgezeigt. Weiter werden fuer den Fall der Beheizung des Hauptraums der ...
N-ethyl-N-nitrosourea (ENU) mutagenesis has led to the elucidation of several regulator genes for melanocyte and skin development. Here we characterized a mutant from ENU mutagenesis with similar phenotype as that of Splotch mutant, including exencephaly, spina bifida and abnormal limbs in homozygotes as well as white belly spotting and occasionally loop-tail in heterozygotes. This novel mutant was named as Sp(xG). Through genome-wide linkage analysis in backcross progenies with microsatellite markers, the Sp(xG) was confined to a region between D1MIT415 and D1MIT7 on chromosome 1, where notable Pax3 gene was located. Direct sequencing revealed that Sp(xG) carried a nucleotide A894G missense transition in exon 6 of Pax3 gene that resulted in Asn to Asp substitution at amino acid 269 within the highly-conserved homeodomain (HD) DNA recognition module, which was the first point mutation found in this domain in mice. This N269D mutation impaired ...
This richly illustrated toolbook and atlas contains information on all aspects of nmr diagnostic imaging of benign or malignant neoplasms of female and male mammary glands. It offers pinpointed guidance and insight for vocational training and continuing training of radiology assistants, students and medical radiologists. (orig./AJ) [German] Die MRT als hochaufloesendes und schaedigungsfreies Diagnostikum gewinnt gerade in der emotional stark besetzten Mammadiagnostik zunehmend an Bedeutung. Dennoch beherrschen nur wenige Zentren im deutschsprachigen Raum diese Technik, die - eine hohe Reproduzierbarkeit bei fehlender Belastung fuer die Patientin bietet, - invasive Karzinome bereits ab einer Groesse von 5 mm mit hoher Zuverlaessigkeit ausschliessen kann und - gerade bei widerspruechlichen Befunden zwischen klinischer Untersuchung, Roentgenmammographie und perkutaner Biopsie eine wesentliche Entscheidungshilfe bieten kann. Aus einem der fuehrenden Zentren in der ...
The results of the experiments on the pressure oxidation of oil and fat in waste waters shows that the final COD and TOC values decrease with growing temperature and reaction time and decreasing initial concentration. Oxidation of oil and fat in waste water is no straight forward procedure. Therefore it should be compared in the individual case with laternative methods in terms of cost and economic efficiency. (EF) [Deutsch] Die Ergebnisse der Versuche zur Druckoxidation von Oel und Fett in Abwaessern zeigten, dass sich die CSB- und TOC- Endkonzentration verringerte mit steigender Temperatur, Reaktionszeit und verringerter Ausgangskonzentration. Die Oxidierbarkeit von Oel und Fett in Abwaessern ist sehr schwierig. Deshalb sollte in jedem Einzelfall ein Vergleich mit alternativen Verfahren bezueglich Aufwand und Wirtschaftlichkeit vorgenommen werden. (EF)
Fundamental investigations into the biosorption of environmentally relevant heavy metals were carried out with different microbial adsorbents, and processes were proposed for industrial effluents. In order to improve the technology of biosorption processes, attempts were made to improve the sorption efficiency of biological sorbents, and investigations were carried out on the immobilisation of biological adsorbents. (orig.) [Deutsch] Es wurden Grundlagenuntersuchungen zur Biosorption von umweltrelevanten Schwermetallen mit verschiedenen mikrobiellen Adsorbentien durchgefuehrt und an technischen Abwaessern Technologievorschlaege erarbeitet. Zur Verbesserung der Technologie von Biosorptionsprozessen wurden Moeglichkeiten der Steigerung der Sorptionsleistung von Biosorbentien erarbeitet und Untersuchungen zur Immobilisierung der biologischen Adsorbentien durchgefuehrt. (orig.)
This paper provides some results of the research works at low pressure components of steam turbines and some construction solutions resulting in a modernisation. The problems of turbine phases for the transonic flow are analysed with respect to reducing profile and margin losses. The origin and flow of wet steam and its influence on corrosion and erosion is investigated. Inlet and outlet casing of the flow channels and transfer diffuser between second last and last phase are mentioned. (orig.) [Deutsch] Im Beitrag werden einige Ergebnisse der Forschung der Teile von ND-Teilen der Dampfturbinen angegeben, und werden irgendeine Konstruktionsloesungen, die fuer ihre Modernisierung guenstig sind, beschrieben. Kurz wird die Problematik der Turbinenstufen fuer die transsonische Stroemung analysiert, mit Hinsicht auf die Erniederung der Profil- und Randverluste. Weiter ist die Aufmerksamkeit der Entstehung und Stroemung des Nassdampfes im Zusammenhang ...
Report by a participant in the International Nuclear Law School. In 2001, this advanced training course was first offered by the OECD-NEA together with the University of Montpellier and other international partners. This effort is intended to provide an overview of nuclear law, a discipline normally playing a subordinate role in curricula. In this way, a contribution is to be made to the important preservation of the existing knowledge base and to increasing know-how in this field. In 2003, the International Nuclear Law School will be continued with a new curriculum addressed to all interested participants. (orig.) [German] Erfahrungsbericht eines Teilnehmers der Internationalen Schule fuer Nuklearrecht 2002 an der Universitaet Montpellier. Erstmals im Jahr 2001 wurde diese Fortbildungsveranstaltung von der Nuclear Energy Agency der Organisation for Economic Co-operation and Development (OECD-NEA) zusammen mit der Universitaet Montpellier und weiteren ...
High-resolution neutron capture cross section measurements of 55Mn were recently performed at GELINA by Schillebeeckx et al. (2005) and at ORELA by Guber et al. (2007). The analysis of the experimental data was performed with the computer code SAMMY using the Bayesian approach in the resonance parameters representation of the cross sections. The neutron transmission data taken in 1988 by Harvey et al. (2007) and not analyzed before were added to the SAMMY experimental data base. More than 95% of the s-wave resonances and more than 85% of the p-wave resonances were identified in the energy range up to 125 keV, leading to the neutron strength functions S0 = (3.90 0.78) x 10-4 and S1 = (0.45 0.08) x 10-4. About 25% of the d-wave resonances were identified with a possible strength function of S2 = 1.0 x 10-4. The capture cross section calculated at 0.0253 eV is 13.27 b, and the capture resonance integral is 13.52 0.30 b. In the energy range 15 to 120 ...
The use of nitrogen ion implantation to increase the surface hardness of structural steels is well documented. Traditionally this involves the use of high energy nitrogen ion beams (approximately 100 keV), with a relatively low beam current density because high energy beams are necessary to produce the required penetration into the material to achieve a significant depth of hardened material. Hardening needs to occur in a region whose size is comparable with the scale of the deformation associated with the tribocontact. 100 keV nitrogen ions typically penetrate into steels only about 0.1 {mu}m and the range of possible tribological applications is thus restricted by this shallow treatment depth. In plasma nitriding processes the nitrogen ions approach the substrate with much lower energies but the ion currents are sufficiently high to cause considerable substrate heating. In this study an ion beam process has been used which more closely ...
In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the "1"3"7Cs-source with 10.4 GBq and "6"0Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form "1"3"7 Cs 1173.23 and 1332.51 keV"6"0 Co sources, and 14 peaks of "1"3"4Cs and "1"5"4Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show that the detection efficiency of gamma scanning system for 1 MeV ...
Reviewing all hitherto known plans or drafts for a reform of the atomic energy law, one can expect that the current legal concept of affording protection of existing (legal) status of nuclear facilities will not essentially be watered down by future developments, unless an act is passed for a nuclear power phase-out. (orig.) [Deutsch] Die bislang bekannt gewordenen Reformbestrebungen legen die Vermutung nahe, dass der Bestandsschutz fuer atomrechtliche Anlagen, sofern nicht ein Kernenergie-Abwicklungsgesetz zum Tragen kommt, mit Abstrichen auch in Zukunft rechtlichen Bestand haben wird. (orig.)
The rate at which full-scale technology transfer takes place depends on the quality of the supply companies, i.e. training, organisational development and product infrastructure. These parameters are discussed for the example of a water mill, and a flow diagram is presented. [Deutsch] Wie rasch ein umfassender Transfer in Frage kommt, entscheidet sich mit der Qualitaet und dem Niveau der zuliefernden Betriebe. Hierbei sind Ausbildung, Organisationsentwicklung und Produktionsinfrastruktur besonders angesprochen. Fuer eine Wassermuehle werden diese Parameter konkret eroertert und an Durchlaufdiagrammen erlaeutert. (GL)
A singular stress field can occur at the edge of the joint plane in a thermally or mechanically loaded material compound. This stress field was calculated analytically and was compared with the results from the finite element method. If one of the two partners consists of ceramic material, unstable crack spread starting from faults in this strongly stressed area can lead to failure. In linear elastic material, the behaviour of a crack is clearly described by the stress intensity factors. These can be calculated for a known stress distribution in the uncracked structure by the method of the weight function. The corresponding weight functions for surface cracks parallel to the boundary surface were determined with the aid of suitable reference load cases. The effect of the position of the crack in the compound and the elastic constants of the compound are discussed. For examples, the stress intensity factors for cracks in a thermally stressed material compound were determined by the ...
DMT has developed what is called the stepped reforming process. This is an allothermal gasification process which uses hydrogen for a gasification medium. First the biomass is pyrolised by means of a heat transfer material. The escaping gaseous and condensable constituents are hydrogenated, heated in a reforming stage and are made to react to a hydrogen-rich product gas by means of homogeneous gasification. The heat required for this is provided by burning the pyrolysis coke. This makes it possible to dispense with process stages that would involve gasification of solid material and hence require higher pressure levels. The present process also works at ambient pressure. Moreover, stepped reforming promises a number of additional advantages: low-tar product gas containing 60% hydrogen, high cold gas efficiency, no wastewater arisings, robust operating behaviour. This paper outlines the basic ideas that led to the development of stepped reforming process and describes its diverse ...
A compact and energy independent solar-powered refrigeration unit was to be developed to store and transport small quantities of high-quality commodities needing refrigeration. This unit comprises the following matched components: thermo-electrical refrigerator unit, solar generator and transport equipment. The solar generator is a specially developed panel with 36 cells. This unit may best be used in human medicine, veterinary medicine, environmental protection analysis, laboratories and leisure time activities. (BWI)
This report describes the QUEOS facility and gives the results of the first test series performed up to 6/1995. The premixing phase of a steam explosion is investigated experimentally with simulant materials. The transient three-dimensional multi-component interaction of molten corium with water is studied using a large number of small solid spheres at temperatures up to 2300 C. The objective of the experiments is to establish a data base for testing the models of heat and momentum transfer in multi-fluid codes as well as the code`s capability to correctly describe multiphase flows. The experiments have the advantage that the diameter of the `coarse melt fragments` are known and that detailed measurements can be performed without the danger of a steam explosion. In this first series of experiments up to 10 kg of spheres (max. 24000 pieces) were used. The spheres, made of molybdenum or zirconia, were heated to temperatures up to 2000 C and are discharged into 0.5 m{sup 3} of saturated ...
Objective: Optimization and testing of a high temperature combustion chamber for burning coal gas and conventional fuels natural gas or fuel oil. Coal gas is not available in such quantity for testing a full scaled combustion chamber. Therefore the design of the combustion chamber is based of experimental results from model tests and numerical solution procedures. Working program: (1) Analytical model for burning coal gas implemented in an existing computational fluid dynamics (CFD) code. (2) Three-dimensional calculations of a full scaled combustion chamber with a CFD code for flows accompanied by combustion and chemical reaction. (3) Improvement of measuring method for determination of flame temperature and concentration. (4) Temperature and concentration profil measuring in a full scaled combustion chamber by operating with natural gas or fuel oil. Results: An analytical model for burning coal gas was implemented in an existing two-dimensional CFD code. The model gave acceptable ...
Copper alloys are a suitable tubing material for turbine condensers and heat exchangers. Due to problems with corrosions copper alloys increasingly are displaced by high-grade steel and titanium. Blockages and surface formation in the pipes, disturbance of the oxide coating formation, erosion and quality faults with the production are the causes for the corrosion. In the contribution under consideration counter measures are designated for the solution of the problems with corrosions. The application limits for different copper alloys are designated. Recommendations for the optimized operation are given.
Purpose: To determine the value of MRI in the postoperativ evaluation of a singular ventricle compared to echocardiography and cardiac catheterization. Materials and methods: Thirty-one patients (range: 6 months to 30 years) with a functional single ventricle following palliative corrective operations. Five patients had a Blalock-Taussig-Shunt, 8 patients a Glenn-Anastomosis and 18 a cavopulmonary shunt (6 with classic Fontan-Circulation, 12 with modified cavopulmonary anastomosis). The results in terms of postoperative morphologic changes were compared to percutaneous echocardiography (31/31) and cardiac catheterization (6/31). Results: Echocardiography, which was performed on all patients, could not visualize the entire length of the tunnel, the Glenn-Anastomosis or the central pulmonary arteries in 70% of the patients due to an inadequate acoustic window. MRI was able to show the entire tunnel in 11/12 patients and the central pulmonary arteries in 30/31 patients. The exact anatomy ...
By characterising the microstructure, quantitative image analysis allows to draw conclusions on the mechanical properties of materials. On fine microstructures with low contrast, e.g. of hardened steels, texture analysis has to be applied for quantification. Feeding texture parameters according to Haralick into a trained neural network, a correlation between the microstructure and the hardness of the steels C45 and 100Cr6 can be achieved. (orig.)
Thermal solar energy plants for water heating have experienced an enormous boom during the last years. Thus, a total of 200000 square metres of collector surface was installed on German rooves in 1991. This was three times as much as in the year before. And this trend of conserving natural resources by using the energy of the sun is still undiminished. (orig.)
A Paderborn group of builder-owners decided in favour of so-called concrete core activation or isothermal component tempering as an alternative to conventional air conditioning. Results are now available for the first year of operation. [German] Am eigenen Neubau hat eine Paderborner Bauherrengemeinschaft die sogenannte Betonkernaktivierung - oder wie es die Bauherren nennen, isotherme Baukoerpertemperierung - als Alternative zu einer konventionellen Klimaanlage installiert. Inzwischen liegen die Messergebnisse von der ueber einjaehrigen Betriebszeit vor. (orig.)
A zinc/air battery is claimed whose performance is improved by omitting separating elements such as diaphragms etc. The cathode and anode spaces are separated by a collector with holes big enough to permit the electrons to pass freely while restraining the anode material. Further, the active material consists of a spherical care of inert material with a zinc coating. Under the zinc coating, the spherical particles have another thin coating of an electropositive material, e.g. nickel. The cell also contains means for circulating the anode suspension.
Already in 1998, the city of Hanover, the Stadtwerke Hannover and six further cities of the region initiated the funding programme 'Hannover proKlim' for promoting energy-relevant modernization measures in domestic buildings. One year later, the social marketing campaign 'Haus-Partner Hannover / Der (H)Eissbaer'' was started, which addresses building owners in Hanover with the intention to induce them to action. The 'Energiepass Hannover' is another important instrument of the campaign. This report takes stock of the results achieved so far. [German] Beim Klimaschutz im Gebaeudebestand lassen sich in Hannover drei Ansaetze hervorheben, die parallel zueinander entwickelt wurden und die in besonderer Weise dazu beitragen, die CO{sub 2}-Emissionen im Gebaeudebestand zu reduzieren: Bereits 1998 hat die Landeshauptstadt Hannover gemeinsam mit den Stadtwerken Hannover und sechs weiteren Staedten der Region ...
Vol. 4 of the DKV Conference Proceedings 2000 contains 19 papers on air quality, thermal comfort, space HVAC engineering and alternative cooling concepts. [German] Der Band 4 des DKV-Tagungsberichts 2000 enthaelt 19 Beitraege. Sie befassen sich mit speziellen Themen der Heiztechnik; Luftqualitaet und Behaglichkeit; Raumlufttechnik und Alternativen Kuehlkonzepten.
Objective was to develop a mathematical model of the cupola furnace (cast iron production) in on-line and off-line process control and optimization. In Phase I, the general structure of the heat transfer, fluid flow, and chemical models were laid out, providing reasonable descriptions of cupola behavior with a one-dimensional representation. Work was also initiated on a two-dimensional model. Phase II was focused on perfecting the one-dimensional model. The contributions include these from MIT, Michigan University, and GM.
It is reported about the adsorptive stripping voltammetric determination of uranium, antimony, tin, vanadium and molybdenum using chloranilic acid as complex forming reagent. The determination limits are in the l{sup 1}-range. (orig.) [Deutsch] Es wird ueber die Bestimmung von Uran, Antimon, Zinn, Vanadium und Molybdaen durch Adsorptions-Stripping-Voltammetrie mit Chloranilsaeure als Komplexbildner berichtet. Die Bestimmungsgrenzen liegen im ng l{sup -1} Bereich. (orig.)
The comprehensive survey explains the indications and the specific value of the modern tomographic modalities with respect to the various diagnostic issues. Numerous reproductions of CT, MRI, US scans illustrate the aspects discussed. (orig./CB) [German] Bildgebende Verfahren kommen bei der Abklaerung von Erkrankungen des weiblichen Urogenitaltrakts ergaenzend zu der klinischen Untersuchung zur Anwendung. Kongenitale Uterusanomalien werden primaer mit der HSG oder der Laparoskopie diagnostiziert. Zusaetzlich koennen der transvaginale US und in unklaren Faellen die MRT eingesetzt werden. Die Diagnose entzuendlicher Erkrankungen des weiblichen Genitaltrakts erfolgt in der Regel klinisch. Schnittbildverfahren werden bei therapieresistenten, komplizierten Faellen angewendet. Initial werden benigne Neoplasien des Uterus mit dem transvaginalen US abgeklaert. Eine Verdickung des Endometriums ist dabei ein unspezifischer Befund und kann auf eine ...
The measuring series was performed from November 1991 through April 1992 in seven drinking-water conditioning plants of the Fichtel mountains area in the north-eastern part of Bavaria, and the results revealed as an annual average a dose of about 1 - 40 WLM. The area of interest is a drinking-water catchment area where the ground water and other water resources include waters particularly rich in radon content, which explains this relatively high dose range. This is why comprehensive, specific local and long-term mearurements were carried out in order to assess the occupational radiation dose in the drinking-water conditioning plants, taking as a model site the conditioning plant of the municipal utilities of Hof in Weissenstadt. These more specific measurements were performed by the Technical Inspectorates (TUeV) of Bavaria and Saxony and the isotope laboratory of Georg-August University of Goettingen in mid-April 1994 (Goettingen University, TUeV Saxonia and Bavaria) and from June ...
A fuel cycle economic analysis was performed on four fuel cycles to provide a baseline for initial cost comparison using the Gen IV Economic Modeling Work Group G4 ECON spreadsheet model, Decision Programming Language software, the 2006 Advanced Fuel Cycle Cost Basis report, industry cost data, international papers, the nuclear power related cost study from MIT, Harvard, and the University of Chicago. The analysis developed and compared the fuel cycle cost component of the total cost of energy for a wide range of fuel cycles including: once through, thermal with fast recycle, continuous fast recycle, and thermal recycle.
The basis of assessment for particulate exhaust emissions is the gravimetric analysis of the particle concentration of diluted exhaust gases at temperatures below 52 C. This is very time consuming and takes sufficient sensitivity at low particulate emission rates like downstream of particle filters. For this reason the C/S-method, based on the thermographic analysis of carbon and sulfur, has been developed as an alternative to the gravimetric anallysis. This method yields particle mass as well as the main particle compounds. Comparisons between both methods have been carried out for heavy duty and automobile diesel engines as well as road vehicles and large diesel engines. The tests were conducted with commercial diesel fuel and also with other fuels, such as heavy oils. It could be shown that the C/S-procedure yields the same results as the gravimetric procedure independent of engine, engine mode and kind of fuel. The analysis of all important particulate compounds - elemental carbon ...
The development of new steels is always a challenge for the manufacturer of filler metals. In many cases it is obvious that some properties of the base metal cannot be fulfilled with matching filler metals. In some cases, dissimilar filler metals can solve the problem in some cases, there is no chance to meet the requirements of the base metal (for example yield strengths of new ultra high strength steels). This paper deals with different kinds of new steels and the requirements for the weld metal with examples from motor car industry (Mangan Austenite), crane (Ultra high strength steels), earthmoving machinery (Wear-resistant steels) and offshore (Supermartensitic steels). Specific problems will be discussed and best solutions will be highlighted. These examples make clear that the success of new kinds of steels in the market depends on solving the joining problems of these steels. (Abstract Copyright [2007], Wiley Periodicals, Inc.) [German] Die Entwicklung von neuen Staehlen ist ...
Jittery (ji) is a recessive mouse mutation on Chromosome 10 characterized by progressive ataxic gait, dystonic movements, spontaneus seizures, and death by dehydration/starvation before fertility. Recently, a viable neurological recessive mutation, hesitant, was discovered. It is characterized by hesitant, uncoordinated movements, exaggerated stepping of the hind limbs, and reduced fertility in males. In a complementation test and by genetic mapping we have shown here that hesitant and jittery are allelic. Using several large intersubspecific backcrosses and intercrosses we have genetically mapped ji near the marker Amh and microsatellite markers D10Mit7, D10Mit21, and D10Mit23. The linked region of mouse Chromosome 10 is homologous to human 19p13.3, to which several human ataxia loci have recently been mapped. By excluding genes that map to human 21q22.3 (Pfkl) and 12q23 (Nfyb), we conclude that jittery is not likely to be ...
A study conducted at the IHS had the aim to obtain basic information on whether it is possible to build flow turbines following the free jet principle that are on a par with, or superior to, the conventional design, especially in terms of performance and the efficiency curve. Several inflow contours with a ventilated free jet and a conventional flow turbine were studied. The direct comparison of these variants revealed a slightly enhanced peak load efficiency and a very distinct superiority of the free jet contour during partial load. But the efficiency of all variants failed to attain the values claimed by commercial manufacturers. As compared to the initial contour, peak load efficiency was enhanced by 5 per cent. During partial load, the variants studied showed a distinct superiority of the free jet concept over the contour of conventional flow turbines. (orig.) [Deutsch] Am IHS wurde eine Untersuchung mit dem Ziel durchgefuehrt, grundlegende Aussagen zu ...
The presented paper describes the formulation of the fractional mass balances which are used to calculate the concentration and size distribution of char in the balance cells of a circulating fluidized bed boiler. In case of using the shrinking core model additionally the distribution of conversion of the char particles is calculated. Basically two reaction models (a shrinking particle and a shrinking core model) are available to describe the combustion process. The model considers all essential physico/chemical phenomena (primary fragmentation, attrition, mass transfer to gas phase) which have to be taken into account for the description of the combustion process. The model is part of an overall simulation program for circulating fluidized bed boilers. This engineering simulator has been developed to return the main performance parameters of such systems like temperature along the furnace height, size distribution of balanced solid components, heat flows at the different heat ...
About ten years ago microbiologically influenced corrosion manifested on stainless steel pipes used with river water for cooling a chemical plant. The pipe material was similar to Type 316 L. After only six weeks of operation pinhole leaks occurred nearly simultaneously at several welded joints of the pipe. The material degradation was simulated in laboratory and field corrosion tests. Microbiologically influenced corrosion failures also appeared on the pipes of a tubular heat exchanger of duplex steel Type 31803 and on carbon and stainless steel pipes in industrial waste water purification plants after these plants had been modernized with a biological purification unit. The basics of microbiologically influenced corrosion phenomena and typical corrosion failures of pipes will be described. (orig.) [German] Vor etwa zehn Jahren sind in einer neu errichteten chemischen Produktionsanlage an einer mit Flusswasser beaufschlagten Kuehlwasserleitung aus hochlegiertem ...
It is necessary to measure strength and creep behavior to guarantee the safe and reliable usage of refractory alloys at extremely high temperatures. In the literature there is very little information available about the properties of Mo-Re alloys at temperatures higher than 1000 C. A special test facility has been designed and built for stress-rupture testing at very high temperatures (up to 3000 C) of refractory metals and alloys in inert atmospheres. - The stress-rupture strength as well as the creep behavior of molybdenum-rhenium alloys with rhenium contents between 41 and 51 wt.% have been determined at temperatures ranging from 1200 to 2000 C, and rupture times of up to 10 hours using this facility. Previous measurements of stress-rupture strength and creep behavior of pure rhenium have been compared with the measurement results of Mo-Re alloys. - The discussion of the values measured is based on metallographic test results and scanning electron microscopy (SEM) images of Mo-Re ...
CNG vehicles suffer from an uncontrolled temperature rise of the gas inside the tank during the filling process and heat exchange with the environment leads to variable filling levels. A partly filled tank reduces the range of CNG vehicles and works as a impediment to the spreading of environmentaly more friendly CNG vehicles. The increase of the pressure inside the tank combined with a prolongation of the filling time beyond three minutes can reduce the deficit of the filling process. For economic reasons the time required for refuelling should be as short as possible without the need to operate the filling station with a critical pressure. To meet this target the current technique requires further improvement. (orig.) [Deutsch] Die betriebliche Praxis bei Tankvorgaengen von Erdgasfahrzeugen zeigt, dass waehrend des Tankvorganges die Temperatur des getankten Erdgases im Fahrzeugtank ansteigt. Waehrend und nach Beendigung des Tankvorganges findet ein Temperaturausgleich ...
Molybdenum is an essential element for living organisms. Moreover its radionuclides may represent an incorporation risk for members of the public and/or radiation workers after a nuclear accident or a release of radioactive materials. However, only few reliable data on Mo biokinetics in humans were available. The results of recent tracer kinetic investigations with stable isotopes have shown several differences from the ICRP data with regard to the processes of intestinal absorption and of excretion. As a consequence, the dose coefficients calculated with a revised biokinetic model deviate from the ICRP estimates. By ingestion of {sup 99}Mo radionuclides with solid food, for example, the dose to the colon may be higher of a factor up to 1 order of magnitude, due to the fraction of non-absorbed material which traverses the gastro-intestinal tract. (orig.) [Deutsch] Molybdaen ist einerseits ein fuer Lebewesen essentielles Spurenelement, andererseits koennen radioaktive Mo-Isotope im ...
The article deals with the problem of a humidity addition to thermal conductivity, diffusion and latent heat effects in heat transfer through building components. It shows with examples humidity effects for exterior walls with core insulation, with composite insulation system as well as for insulated roof membrane assemblies. From these it can be summarized that - sorption humidity is for today`s construction conditions (good thermal insulation and humidity protection) a suitable reference quantity for the determination of practice-oriented, substance-specific and physically correct humidity additions to the thermal conductivity of hygroscopic components; - diffusion and latent heat effects are in case of good rain imperviousness and low water absorbing capacity of the exterior component layers of secondary importance for transmission heat losses; - an increase in insulating layer thickness in order to improve the thermal insulation is possible without humidity problems; - today`s ...
Experiments for lifetime prediction of the first wall are being carried out within the framework of the European fusion reactor programme. Defects such as notches and cavities may develop in the first wall and may initiate under cyclic thermal stress cracking processes which may reduce the service life of the material. For examination of crack growth, specimens with defined initial notches were prepared and subjected to cyclic thermal loads. The paper shows that the eddy current method is suitable for detecting and revealing the crack growth processes even under conditions of complex geometry, as e.g. cracks in inner bores. The experiments indicated particularly susceptible, critical spots in the first wall and yielded crack growth rates of use for lifetime calculations. (orig./CB) [Deutsch] Im Rahmen des europaeischen Fusionsreaktorprogramms werden Untersuchungen zur Lebensdauervorhersage der Ersten-Wand durchgefuehrt. Die Erste-Wand kann Fehler in Form von Lunkern und Kerben ...
Early recognition of recurrence and work-up of clinically indeterminate lesions may be impaired after reconstruction with silicone implants due to superimposition of the implant or to scarring. This study was undertaken to evaluate the use of contrast-enhanced MRI in patients with silicone implant after breast cancer. Contrast-enhanded MRI was offered to 169 patients. Comparative two- to three-view mammography was also performed in 169 patients, as well as comparative sonography in 144 patients. Conventional imaging and clinical examination detected only 8/13 recurrences, whereas 12/13 were detected by MRI. One recurrence had been visible as a strongly enhancing 2-mm dot in a previous examination (2 years before), but was not called. It was therefore counted as false negative. In addition, multicentricity was detected by MRI alone in two of three cases. MRI correctly diagnosed scar tissue in all cases with indeterminate findings. However, due to false-positive calls caused by enhancing ...
The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. Postoperative HRCT depicted bony erosions caused by recurrent cholesteatoma, bony defects ...
The staging of patients with multiple myeloma demands sensitive imaging methods for the assessment of the skeletal system. MRI allows for direct visualization of the bone marrow which exhibits five different infiltration patterns in multiple myeloma: 1. normal appearance of the bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. ''salt and pepper'' pattern with inhomogeneous bone marrow signals due to multiple fat islands. The combination of T1w-SE and STIR sequences is best suited for detecting all infiltration patterns and for the differential diagnoses e. g. hemangiomas. With parallel imaging in MRI, acquisition times can be markedly reduced and whole-body screening of the bone marrow can be achieved within 30 min. MRI is superior to radiography for the detection of focal as well as diffuse infiltration. Multidetector computed tomography and especially 16- and 64-detector row ...
Objective: To evaluate the treatment of malignant biliary stenoses and occlusions using a new stent. Methods: In a prospective study, 25 patients with malignant obstructive jaundice were treated with SMART stents. The handling and the quality of stent expansion were documented. Stent function was assessed 2-4 days after intervention by cholangiography and laboratory tests. A follow-up was performed three months, after stent placement. Results: All lesions were treated successfully, with a total of 35 stents implanted. In 14 patients a further balloon dilatation was performed after stent placement (8-10 mm diameter/40-80 mm length). The mean serum bilirubin level decreased significantly from 11.6 mg/dl to 4.6 mg/dl after intervention (p<0.05). The follow-up showed a mean serum bilirubin level at 4.0 mg/dl. In 4 cases (16%) a further intervention (PTCD or stent) was performed. Six patients died due to tumor progression. The stents proved to be patent in 79% (n=15) of patients ...
From autumn this year, the FRJ-2 of the Research Center Juelich will be supplying molybdenum targets to the Institut National des Radioelements in Fleurus, Belgium - which deals in medical radio-isotopes worldwide - thus helping to meet the need for technetium-99, which is used in the medical profession for diagnostic purposes because of its favourable radiological characteristics. Technetium-99 is formed as a result of the radioactive decay of molybdenum-99. For many years now, molybdenum has been produced by the irradiation of uranium in research reactors, so that the initiation of molybdenum production in the FRJ-2 is not especially new. What is unusual, however, are the particular peripheral conditions which result from the combination of the irradiation requirements, a predetermined target design and the technical characteristics of the reactor and which necessitated special solutions. This applies especially to the handling of the targets after irradiation, which is much more ...
Purpose: To evaluate a T{sub 2}-weighted URSE sequence for the assessment of pulmonary infiltrations in comparison to CT. Methods: 28 MRT scans of 22 patients with confirmed pneumonia were recorded on a 1.5 Tesla apparatus with an expiratory and diastolic triggered, T{sub 2}-weighted ultrafast-spin-echo sequence in axial slice mode with the following parameters: TR{sub eff}/T{sub E}/Turbofactor 2000-4000/90 ms/21-23; slice thickness/separation 6/0.6 mm; FOV 360 mm; 24 slices. 24 spiral CTs (sice thickness/table advance: 1-2 mm/10 mm) were available for comparison. The separate evaluation of MRTs and CTs was performed by three radiologists in a consensus procedure with regard to pulmonary lesions (e.g., infiltration, round foci, net patterns) and image quality of the MRTs (4-step scale). Results: In 71% of the cases the CTs and MRTs agreed with the diagnosis and representation of the lesions, in 25% MRT was superior. MRT was better for the detection of pulmonary abscesses. In 93% the ...
MRI provides a non-invasive diagnostic tool complementing echocardiography on one hand, and showing advantages over echocardiography, on the other hand, especially after corrective procedures. The multiple different MRI sequences need to be adapted to examinations of children and patients with congenital heart disease (CHD), and can be used to detect morphologic changes, blood-flow in the heart and thoracic vessels and diastolic or systolic function of myocardium. Several factors determine the success of the examination of a complex congenital heart disease or a postoperative situs. Pediatric radiologists and radiologists experienced in congenital heart diseases have to work in close cooperation. Echocardiography should be performed before MRI. The results of prior examinations and the clinical history of the patients, including possible palliative or reconstructive operations, must be available before MRI to guide the planning of the examination. With a systematic segmental approach ...
Purpose: Evaluation of the diagnostic efficacy and cost-benefit of contrast enhanced CT (CT) and MRI pre- and post-SPIO-particles in focal hepatic disease with consideration of therapeutic outcome. Results: In 34/52 (65.4%) of the cases the correct diagnosis was primarily stated by CT (sensitivity [se.] 85.2%, specificity [sp.] 44.0%). In additional 10/52 of the cases unenhanced MRI (se. 91.4%, sp. 75.0%) enabled correct diagnoses, and in another 6 cases the diagnosis was established only by SPIO-MRI (se. 100%, sp. 86.7%). Considering the possible therapeutic recommendation arising from each modality, CT would have induced needless therapy costs of 191,042 DM, unenhanced MRI of 171,035 DM, and SPIO-MRI of 7,311 DM. In comparison to the real therapy costs of 221,873 DM, this would have corresponded to an unnecessary increase of therapy costs of 86.1%, 77.1%, and 3.3%, respectively. In two cases (91 hemangioma, 1 regenerative nodule) all modalities failed, causing unnecessary surgery in ...
Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI T{sub 1}-weighted scans the tumors were homogeneous and hypointense, ...
Present day mammography has not been able to make use of the advantages of digital luminescence radiography because of the limited spatial resolution. The recent development of electromagnetic focusing X-ray tube with effective focal spot sizes from 0.04 to 0.12 mm allows radiographic direct magnification with less geometric blur. It is now possible to combine direct magnification mammography with digital luminescence radiography. By combining high quality storage phosphor screens with an HQ-workstation a spatial resolution of 8 lp/mm is possible for 1.7-fold magnification. For 4-fold spot magnification views spatial resolution can be theoretically increased to approx. 20 lp/mm. One important advantage of digital radiography is the possibility of image-postprocessing. This article presents two sets of standard parameters and three sets of image dependent parameters for better imaging of specific lesions, such as microcalcifications. The introduction of the storage phosphor screen ...
Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis studies diffuse infiltration is inferior to ...
Purpose: To report the detection of con-compacted ventricular myocardium (NVCM) with MRI compared to echocardiography in 8 patients. Material and methods: Non-compaction of the ventricular myocardium is a congenital disorder characterized by an altered structure of the myocardial wall resulting from an intrauterine arrest in endomyocardial embryogenesis. The morphological findings consist of a prominent meshwork of multiple myocardial trabeculations and deep intertrabecular recesses, communicating with the left ventricular cavity. 8 consecutive patients (mean age 7.3 years) with clinical and echocardiographic signs of NCVM were examined by MRI (1.5 T, Vision, Siemens) in short axis and 2- and 4-chamber views, using T{sub 1}-weighted TSE and Cine-GRE in 6 patients and true FISP sequences in 2 patients. MRI and echocardiography were evaluated for visibility, signs of NCVM and involvement of myocardial wall segments. Thickness was measured for non-compacted and compacted myocardium and ...
Purpose: {sup 31}P-MRS is used to assess the influence of sex and age on quadriceps muscle metabolism before and after exercise. Materials and Methods: 32 healthy volunteers (15 women, 17 men; mean age: 38{+-}17 yrs.) were examined by dynamic phosphorus-31 ({sup 31}P) magnetic resonance spectroscopy (MRS). In the magnet, the quadriceps muscle was stressed by an isometric and an isotonic form of exercise until exhaustion, respectively. Results: Resting conditions: With increasing subjects` age, the ratio {beta}-adenosine triphosphate/total phosphate decreased (r=-0.37; p=0.02). With increasing subjects` age, the ratios inorganic phosphate/phosphocreatine (r=0.79; p=5x10{sup -8}), phosphomonoester/{beta}-adenosine triphosphate (r=0.74; p=10{sup -6}) and phosphodiester/{beta}-adenosine triphosphate (r=0.62; p=10{sup -4}) increased. The pH was the only one of the evaluated spectroscopic parameters which showed a sex-dependence: Female subjects had a significantly lower pH (7.03{+-}0.02) ...
Introduction: The goal of this study was to compare contrast-enhanced T1-weighted Flash and Turbo-Flash sequences with conventional spin-echo sequences as a basis for planning high-precision radiotherapy. Methods: A total of 25 consecutive patients with different intracranial tumors and a disrupted blood-brain barrier were studied. T1-weighted Flash, Turbo-Flash and conventional spin-echo images were evaluated after controlled 30-s infusion of 0.1 mmol/kg body weight of Gd-DTPA. The evaluation of the three sequences included the measurement of the signal- and contrast-to-noise ratios, the visual inspection of the tumors and artifacts, and the measurement of tumor size. Results: The signal- and contrast-to-noise ratios were significantly (P<0.05-0.01) lower for Flash and Turbo-Flash than for conventional spin-echo sequences. However, visual inspection of the contrast-enhancing tumors revealed in 23 and 24 of 25 lesions of Flash and Turbo-Flash images, respectively, good or very good ...
In an epidemiological study of the somatic late effects risk following incorporation of a short lived {alpha}-emitter, 1473 ankylosing spondylitis patients treated with repeated intravenous injections of {sup 224}Ra in the years 1948 - 75, have been observed in the GSF. The usual therapeutic plan consisted of a total of 10 - 12 injections of 1.036 MBq (28 {mu}Ci) of {sup 224}Ra each, given at weekly intervals; this would result in an cumulative {alpha}-dose of 0.56 - 0.67 Gy to the marrow-free skeleton of a 70-kg-man (standard man). These patients have been followed together with a control group of ankylosing spondylitis patients not treated with radioactive drugs and/or X-rays. Until May 1993 (mean follow-up time 19.9 yr), 595 patients of the exposure group and 722 patients of the control group have died, causes of death have been ascertained for 578, resp. 668 patients. Among others we observed in the exposure group 10 cases of leukaemia (vs. 2.7 - 2.8 cases expected, p < 0.001) ...
Aim: Today, MRI is an integral part of the presurgical evaluation of patients suffering from partial epilepsy. These patients frequently show focal morphological abnormalities with potential epileptogenic character and surgical resection of these lesions is associated with superior postsurgical outcome as to seizure frequency. Apart from easily detectable defects, such as post-traumatic lesions or cerebral infarction, as wide variety of mainly small abnormalities can be detected using MRI. Methods: In this study, 484 patients suffering from partial epilepsy of temporal or frontal onset were evaluated for the incidence of different lesions in this population. Results: All lesions found were included without evaluating their potential epileptogenicity, which remains to be proven using other procedures (EEG, SPECT, PET, etc.). Involvement of the hippocampal formation was a major finding in temporal lobe epilepsy, which could be detected as sclerosis (T2w-images), atrophy (T2w-TSE or ...
Tumours lesions of the temporal bone and of the cerebello-pontine angle are rare.This tumours can be separated into benign and malignant lesions. In this paper the CT and MRI characteristica of tumours of the temporal bone and the cerebello-pontane angle will be demonstrated. High resolution CT (HRCT) as usually performed in the axial plane are using a high resolution bone window level setting, coronal planes are the reconstructed from the axial data set or will be obtained directly. With the MRI FLAIR sequence in the axial plane the whole brain will be scanned either to depict or exclude a tumour invasion into the brain. After this,T2-weighted fast spin echo sequences or fatsuppressed inversion recovery sequences in high resolution technique in the axial plane will be obtained from the temporal bone and axial T1-weighted spinecho sequences before and after the intravenous application of contrast material will be obtained of this region. Finally T1-weighted spinecho sequences in high ...
We study the three-nucleon force in chiral effective field theory with explicit {delta}-resonance degrees of freedom. We show that up to next-to-next-to-leading order, the only contribution to the isospin symmetric three-nucleon force involving the spin-3/2 degrees of freedom is given by the two-pion-exchange diagram with an intermediate delta, frequently called the Fujita-Miyazawa force. We also analyze the leading isospin-breaking corrections due to the delta. For that, we give the first quantitative analysis of the delta quartet mass splittings in chiral effective field theory including the leading electromagnetic corrections. The charge-symmetry breaking three-nucleon force due to an intermediate delta excitation is small, of the order of a few keV.
A significant amount of X-rays were detected as a leakage from some of the Crooke`s tubes which were used in the teaching of science at junior and senior high schools in Japan. We measured the leaked dose of X-rays from the Crooke`s tubes with ionizing chambers, film badges and TLDs. The maximum leaked dose at 5cm distance from those tubes was estimated 143mSv/h. The effective energy of leaked X-rays was 19.3keV. The maximum dose of students exposed during the teaching of science were estimated 0.15mSv per experiment, which exceeded the value recommended in the ICRP publication 36. (author)
Among the investigations conducted on the space shuttle flight STS 3 March 1982 was an experiment in which a 1-keV, 100-mA electron gun was pulsed at 3.25 and 4.87 kHz. The resultant waves were measured with a broadband plasma wave receiver. At the time of flight the experimental setup was unique in that the electron beam was square wave modulated and that the shuttle offered relatively long times for in situ measurements of the ionospheric plasma response to the VLF pulsing sequences. In addition to electromagnetic response at the pulsing frequencies the waves exhibited various spectral harmonics as well as the unexpected occurrence of satellite lines around those harmonics. Both phenomena occurred with a variety of different characteristics for different pulsing sequences.
A time-of-flight mass spectrometer has been constructed to measure the energy spectra of particles scattered by 10/sup 0/ with primary energies between 200 eV and 15 keV. The energy resolution ..delta..E/E of the system is between 0.1 and 0.4%. Energy spectra of scattered molecules and their dissociation products are shown for 570 eV H/sub 2//sup +/ and 4430 eV N/sub 2//sup +/ as projectiles. Electron capture into unbound states of the neutral molecule, with perhaps some contribution from mutual scattering within the molecule, appears to explain the observed dissociation product energy spectra peak widths.
A time-of-flight mass spectrometer has been constructed to measure the energy spectra of particles scattered by 10"0 with primary energies between 200 eV and 15 keV. The energy resolution #DELTA#E/E of the system is between 0.1 and 0.4%. Energy spectra of scattered molecules and their dissociation products are shown for 570 eV H_2"+ and 4430 eV N_2"+ as projectiles. Electron capture into unbound states of the neutral molecule, with perhaps some contribution from mutual scattering within the molecule, appears to explain the observed dissociation product energy spectra peak widths. (orig.).
The neutron capture cross-section of {sup 234}U has been measured for energies from thermal up to the keV region in the neutron time-of-flight facility n-TOF, based on a spallation source located at CERN. A 4{pi} BaF{sub 2} array composed of 40 crystals, placed at a distance of 184.9 m from the neutron source, was employed as a total absorption calorimeter (TAC) for detection of the prompt {gamma}-ray cascade from capture events in the sample. This text describes the experimental setup, all necessary steps followed during the data analysis procedure. Results are presented in the form of R-matrix resonance parameters from fits with the SAMMY code and compared to the evaluated data of Endf in the relevant energy region, indicating the good performance of the n-TOF facility and the TAC. (authors)
We propose an X-ray mission called Xenia to search for decaying superweakly interacting Dark Matter particles (super-WIMP) with a mass in the keV range. The mission and its observation plan are capable of providing a major break through in our understanding of the nature of Dark Matter (DM). It will confirm, or reject, predictions of a number of particle physics models by increasing the sensitivity of the search for decaying DM by about two orders of magnitude through a wide-field imaging X-ray spectrometer in combination with a dedicated observation program. The proposed mission will provide unique limits on the mixing angle and mass of neutral leptons, right handed partners of neutrinos, which are important Dark Matter candidates. The existence of these particles is strongly motivated by observed neutrino flavor oscillations and the problem of baryon asymmetry of the Universe. In super-WIMP models, the details of the formation of the cosmic web are different from ...
Several different aspects of the influence of the target backing on in-beam electron spectra following compound nuclear reactions induced by accelerated ions at tandem energies irradiating backed targets are discussed in detail. This discussion is illustrated by a few typical examples, such as "1"2C"5"+ and "3"1P"1"0"+ beams at 4 MeV/u bombarding Sn(+Be), Sn(+Au), Pb(+C) backed targets. Moreover, the relative influence of electron backscattering, electron Doppler shift and Doppler broadening as well as #delta#-electron emission on the low energy electron spectra (E_e#<=#100 keV) obtained under such conditions are investigated in the frame of the available experimental data. (orig.).
We present results from a kinetic Monte Carlo simulation of boron transient enhanced diffusion (TED) in silicon. Our approach avoids the use of phenomenological fits to experimental data by using a complete and self-consistent set of values for defect and dopant energetics derived mostly from {ital ab initio} calculations. The results predict that, during annealing of 40 keV B-implanted Si at 800{degree}C, there exists a time window during which all the implanted boron atoms are substitutional. At earlier or later times, the interactions between free silicon self-interstitials and boron atoms drive the growth of boron clusters and result in an inactive boron fraction. The results show that the majority of boron TED takes place during the growth period of interstitial clusters and not during their dissolution. {copyright} {ital 1998 American Institute of Physics.}
We present results from a kinetic Monte Carlo simulation of boron transient enhanced diffusion (TED) in silicon. Our approach avoids the use of phenomenological fits to experimental data by using a complete and self-consistent set of values for defect and dopant energetics derived mostly from ab initio calculations. The results predict that, during annealing of 40 keV B-implanted Si at 800 degree C, there exists a time window during which all the implanted boron atoms are substitutional. At earlier or later times, the interactions between free silicon self-interstitials and boron atoms drive the growth of boron clusters and result in an inactive boron fraction. The results show that the majority of boron TED takes place during the growth period of interstitial clusters and not during their dissolution. copyright 1998 American Institute of Physics.
The effect of ion implantation on the aqueous corrosion resistance of Zr-4 in deaerated 1N H_2SO_4 was studied with the potentiokinetic technique. The Zr-4 alloy was bombarded with 5x10"1"4-2x10"1"6 Ar/cm"2 of 190 keV. It was found that the passive current density of Zr-4 decreases with increasing implantation dose. Photoelectrochemical results show that the ion implantation of Ar in Zr-4 raises the flatband potential of its passive film. AES was employed to analyze the surface of the passive film of Zr-4. The decrease in passive current density may be attributed to a thickening oxide layer on Zr-4 and a decrease in concentration of oxygen vacancies in its passive film. ((orig.)).
The emission of the plerion G21.5-0.9 appears more extended in X rays than in radio. This is an unexpected result because it would imply that short-lived X-ray electrons may reach distances even larger than radio electrons. Applying an empirical relationship between dust scattering optical depth and photoelectric column density, the measured column density leads to a large optical depth at 1 keV, of about 1. Therefore we investigate the hypothesis that the detected halo be an effect of dust scattering, re-analyzing an Cal/PV XMM-Newton observation of G21.5-0.9 and critically examining it in terms of a dust scattering model. We also present a spectral analysis of a prominent extended feature in the northern sector of the halo.
A technique has been developed which enables the direct sputter generation of atomic negative ion beams of all members of the Group IA elements (Li, Na, K, Rb and Cs). The method is based on the use of sputter samples formed by pressing mixtures of the carbonates of the Group IA elements and 10% (atomic) Cu, Ag or other metal powders. The following intensities are typical of those observed from carbonate samples subjected to approx. = 3 keV cesium ion bombardment: Li/sup -/: greater than or equal to 0.5 ..mu..A; Na/sup -/: greater than or equal to 0.5 ..mu..A; K/sup -/: greater than or equal to 0.5 ..mu..A; Rb/sup -/: greater than or equal to 0.5 ..mu..A; Cs/sup -/: greater than or equal to 0.2 ..mu..A.
Irradiation of EP-823 (16Cr12MoWsiVNbB) ferritic-martensitic steel with 7-MeV Ni++ ions and with 30- and 70-keV He+ ions at a temperature of 500?C was followed by an increase in the microhardness, which was due to both radiation point defects and changes in the phase composition and the dislocation structure of the steel. It was found that the dependence of the largest relative increase in the microhardness on the concentration of radiation-induced point defects in the near-surface region of the steel under irradiation with different ions correlated with an analogous dependence of the surface segregation of silicon and chromium.
The effect of {ital in} {ital situ} photoexcitation during boron ion implantation on subsequent transient enhanced B diffusion in Si has been investigated. Photoexcitation using a mercury arc lamp was performed during B{sup +} implantation at 35 keV for a dose of 5{times}10{sup 14} cm{sup {minus}2} at 177 K. A reduction in the electrical activation dip, i.e., reverse annealing effect, in the temperature range 550--700 {degree}C was observed. Also, the transient enhanced diffusion of B, measured using SIMS following 800 {degree}C, 30 min annealing, was suppressed. Both effects demonstrate that the creation of self-interstitials during the implantation process is significantly reduced. {copyright} {ital 1995} {ital American} {ital Institute} {ital of} {ital Physics}.
The effect of in situ photoexcitation during boron ion implantation on subsequent transient enhanced B diffusion in Si has been investigated. Photoexcitation using a mercury arc lamp was performed during B"+ implantation at 35 keV for a dose of 5x10"1"4 cm"-"2 at 177 K. A reduction in the electrical activation dip, i.e., reverse annealing effect, in the temperature range 550--700 degree C was observed. Also, the transient enhanced diffusion of B, measured using SIMS following 800 degree C, 30 min annealing, was suppressed. Both effects demonstrate that the creation of self-interstitials during the implantation process is significantly reduced. copyright 1995 American Institute of Physics.
We have monitored a Type II outburst of the Be/X-ray binary MXB 0656-072 in a series of pointed RXTE observations during October through December 2003. The source spectrum shows a cyclotron resonance scattering feature at 32.8 +/- 0.5 keV, corresponding to a magnetic field strength of (3.67 +/- 0.06) x 10^12 G and is stable through the outburst and over the pulsar spin phase. The pulsar, with an average pulse period of 160.4 +/- 0.4 s, shows a spin-up of 0.45 s over the duration of the outburst. From optical data, the source distance is estimated to be 3.9 +/- 0.1 kpc and this is used to estimate the X-ray luminosity and a theoretical prediction of the pulsar spin-up during the outburst.
Studies on the separation of Ag(I) during the recovery of Pu from analytical waste generated during potentiometric determination of Pu using AgO as oxidant, by precipitation of Pu as ammonium plutonium (III) oxalate have shown that most of the Ag(I) is separated during the reduction of Pu to Pu(III) state by ascorbic acid. A decontamination factor of 54 was obtained. Additional a decontamination factor of 5.8 was obtained during the precipitation of Pu as ammonium plutonium (III) oxalate. The Ag content was determined by gamma spectrometry, using "1"1"1Ag as a tracer (T_1_/_2 7.45 d, #gamma# 342.1 keV) and HPGe as detector. The studies indicate that Ag is preferentially separated almost quantitatively during the recovery of plutonium, when acidity adjustment is done with NaOH instead of NH_3. (author)
The energy level schemes of /sup 192/Os and /sup 192/Pt have been established on the basis of ..gamma..-..gamma.. coincidence studies using a dual parameter data collection system. Ge(Li) detectors were employed to study the gamma spectra produced in the E.C. and ..beta../sup -/ decays of /sup 192/Ir to /sup 192/Os and /sup 192/Pt, respectively. Thirteen new transitions and three new levels at 1146.95, 1237.35 and 1913.76 keV are suggested. Relative intensities from singles measurements, branching ratios, ..cap alpha..(K) and log ft values were calculated and multipolarities, spins and parities deduced. Comparisons are made with predictions of the Interacting Boson Model calculated on the basis of an O(6) to SU(3) transition.
The energy level schemes of "1"9"2Os and "1"9"2Pt have been established on the basis of #gamma#-#gamma# coincidence studies using a dual parameter data collection system. Ge(Li) detectors were employed to study the gamma spectra produced in the E.C. and #beta#"- decays of "1"9"2Ir to "1"9"2Os and "1"9"2Pt, respectively. Thirteen new transitions and three new levels at 1,146.95, 1,237.35 and 1,913.76 keV are suggested. Relative intensities from singles measurements, branching ratios, #alpha#(K) and log ft values were calculated and multipolarities, spins and parities deduced. Comparisons are made with predictions of the Interacting Boson Model calculated on the basis of an O(6) to SU(3) transition. (orig.).
The dependence of the efficiency of a coaxial IGC-30 Ge detector on the direction of gamma quanta entry, their energy and the distance from the source is examined. A set of point sources QCR-2 (Amersham, UK) has been used which is arranged consecutively in two perpendicular planes passing through the detector axis, at a distance of 0.1 - 1.3 m (pace 0.1) from its geometric centre for 16 different angles in every plane. Dependence curves of the efficiency on the angle of gamma-quanta hits are obtained for energies 60, 81, 122, 356, 662, 834, 1173 and 1332 keV. Changes in efficiency connected with spatial dividing ability are found out. Using the least squares' method the expected spatial distribution of efficiency is examined with a level of authenticity P > 0.9. The possible causes for the efficiency change and its possible effect on the measurements' precision are discussed. (author).
We have studied, by a Monte Carlo simulation code ACAT-DIFFUSE, the fluence-dependence of the amount of retained helium atoms in tungsten carbide at room temperature under helium ion bombardment. The retention behavior may be understood qualitatively in terms of irradiation-dependent diffusion coefficient assumed and range. The emission processes from tungsten carbide under helium ion irradiation derived were compared with each other. We have discussed the retention curves for incident energy of 5 keV at incident angles of 0deg and 80deg and of 500 eV at 0deg. The energy spectra of helium atoms reflected from tungsten carbide for incident energy of 500 eV at 0deg and 80deg were compared with those from graphite and tungsten. (author)
He ions incident at grazing angles on Cu(110) and Ni(110) surfaces are neutralised into triplet and singlet states, of which the 3p, 3d and 4d upper states are accessible to optical spectroscopy. In the energy range from 500 eV to 15 keV no significant energy dependence of the relative intensities of singlet and triplet lines was observed for scattering on Cu(110). The intensities from Ni(110) are higher and the singlet to triplet intensity ratio of the 3d to 2p transition is about 6% smaller than that from Cu(110). The results can be explained well by assuming resonant charge capture into excited He and intermediate formation of negative He/sup -/ states.
He ions incident at grazing angles on Cu(110) and Ni(110) surfaces are neutralised into triplet and singlet states, of which the 3p, 3d and 4d upper states are accessible to optical spectroscopy. In the energy range from 500 eV to 15 keV no significant energy dependence of the relative intensities of singlet and triplet lines was observed for scattering on Cu(110). The intensities from Ni(110) are higher and the singlet to triplet intensity ratio of the 3d to 2p transition is about 6% smaller than that from Cu(110). The results can be explained well by assuming resonant charge capture into excited He and intermediate formation of negative He"- states. (orig.).
The present article will review recent advances in focused ion beam (FIB) technology. With increasing demands for scale of integration, microfabrication technology is becoming more important and various new microfabrication tools and processing techniques are desired. FIB is one of the promising tools for future microfabrication technology. This provides maskless patterning capability, which is of importance for process simplification, nanofabrication and in the development of in situ vacuum processing. In situ vacuum processing systems are being developed by combining FIB and a molecular beam epitaxy system. Radiation damage may limit applications of FIB. However, it was demonstrated that low energy FIB (<1 keV) with very high brightness was reached and promising results for low damage processing have been obtained. (orig.).
Although the outer surface of single-walled carbon nanotubes (atomically thin cylinders of carbon) can be involved in a wide range of chemical reactions, it is generally thought that the interior surface of nanotubes is unreactive. In this study, we show that in the presence of catalytically active atoms of rhenium inserted into nanotubes, the nanotube sidewall can be engaged in chemical reactions from the inside. Aberration-corrected high-resolution transmission electron microscopy operated at 80?keV allows visualization of the formation of nanometre-sized hollow protrusions on the nanotube sidewall at the atomic level in real time at ambient temperature. Our direct observations and theoretical modelling demonstrate that the nanoprotrusions are formed in three stages: (i) metal-assisted d...
A brief survey is presented of the methods of preparation and of the applications of radiopharmaceuticals labelled with short-lived positron radionuclides "1"1C, "1"8F, "1"3N and "1"5O which, thanks to their energy level schemes, short half-life and the 511 keV photon radiation energy are almost ideal tracers in modern nuclear medicine and pharmacology. In conjunction with computerized tomography, they represent one of the most sensitive diagnostic imaging methods, the so-called positron emission tomography. In addition, their incorporation in the molecule of a pharmaceutical does not change the biological and chemical properties of the original molecule unlike those of radiopharmaceuticals labelled with technetium, iodine, etc. (author). 125 refs.
P-implantation (10"1"7 ions cm"-"2, 40 KeV) into 304 stainless steel (ss) has been carried out, and an amorphous surface alloy was formed. Polarization studies in deaerated 1N H_2SO_4+ 2% NaCl showed that P-implantation improved both the general and localized corrosion resistance of 304 ss. A comparative study has been carried out between the implanted and unimplanted steel to determine what influence P-implantation has upon the properties of the passive film formed 1N H_2SO_4. The influence of Cl ions on pre-formed passive films was also studied. RHEED, XPS and AES were used to evaluate the nature of the passive films formed in these studies.
P-implantation (10/sup 17/ ions cm/sup -2/, 40 KeV) into 304 stainless steel (ss) has been carried out, and an amorphous surface alloy was formed. Polarization studies in deaerated 1N H/sub 2/SO/sub 4/+ 2% NaCl showed that P-implantation improved both the general and localized corrosion resistance of 304 ss. A comparative study has been carried out between the implanted and unimplanted steel to determine what influence P-implantation has upon the properties of the passive film formed 1N H/sub 2/SO/sub 4/. The influence of Cl ions on pre-formed passive films was also studied. RHEED, XPS and AES were used to evaluate the nature of the passive films formed in these studies.
We reported in previous papers that both the near-uv and the visible photosensitivities of ferroelectric-phase PLZT (lead lanthanum zirconate titanate) ceramics are increased by as much as four orders of magnitude by ion implantation or a combination of thermal diffusion of Al and ion implantation. New results are presented here on high-energy (1 MeV) implants of Al and Ni and coimplants of Al + Ne and Ni + Ne, and these results are compared with earlier 500 keV implants of Al and Cr and coimplants of Al + Ne and Cr + Ne as surface modification techniques for increasing the visible photosensitivity of PLZT. The important role of grain size in determining optimum contrast and resolution of stored optical information is described in terms of new experimental results.
TiH{sub 2} and TiD{sub 2} thick targets were bombarded with 100 to 200 keV protons. Evidence for nuclear reactions was obtained by means of a surface barrier particle detector. Proton irradiation of TiD{sub 2} produced the following observations: {alpha} particle emission identified as (p, {alpha}) reactions from {sup 11}B and {sup 7}Li impurities in the target at ppm concentrations; and {approx}3 MeV proton and {approx}1 MeV triton emission from secondary D-D reactions caused by elastic scattering of the primary proton with a target deuteron. A 3.9 MeV {alpha} particle peak measured by others was not observed. (author)
The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.
Elastic scattering cross sections of keV protons in solids (Z=3-82) are calculated using the partial wave expansion technique and the ''muffin-tin'' bound-atom potential. The differential cross sections for small scattering angles of less than 10deg are smaller than those with the Ziegler-Biersack-Littmark potential at all energies and for all solids, although, for larger angles, the two cross sections agree with each other. The mean free paths of the protons in the solids, obtained from the total cross sections, decrease very slowly with decreasing energy. Furthermore, at low energies they approach half the nearest-neighbor distance, which is taken as the radius of the augmented plane wave sphere in the muffin-tin model of crystalline solids. (orig.).
A time-reversal-violating spin-correlation coefficient in the total cross section for polarized neutrons incident on a tensor rank-2 polarized target is calculated by assuming a time-reversal-noninvariant, parity-conserving ``five-fold" interaction in the neutron-nucleus optical potential. Results are presented for the system $n + {^{165}{\\rm Ho}}$ for neutron incident energies covering the range 1--20 MeV. From existing experimental bounds, a strength of $2 \\pm 10$ keV is deduced for the real and imaginary parts of the five-fold term, which implies an upper bound of order $10^{-4}$ on the relative $T$-odd strength when compared to the central real optical potential.
The Sputter coefficient of accelerated CO{sub 2} cluster ions hitting surfaces of various materials is investigated. For copper it varies proportional to the 2nd power of the energy between 155 and 260 keV. The rate of erosion for different target materials varies by two orders of magnitude from tungsten to PMMA. Diamond is eroded fairly quickly, while aluminum is eroded less than corundum (Al{sub 2}O{sub 3}). No simple correlation of the sputter coefficient on the bulk material properties is found. For copper the angular distribution of sputtered material is measured and found to be following roughly a cosine distribution. By using masks different microstructures have been produced in cobalt-samarium magnets, diamond and glass. (orig.)
The measurement of level in the liquid nitrogen vessel has been carried out by the weight conversion method using weigher or by putting directly a stick in the vessel. On a large CE tank, the pressure difference was read by manometer. These methods can not be used when the vessel does not put on the weigher or the pipe for manometer is stopped. We noticed the interaction between radiation ({gamma}-ray) and substance and applied it to determine the liquid nitrogen level. The results proved it the easy method for measurement of the level in the large CE tank. Cesium 137 ({gamma}-ray energy: 662 keV) was used as the radiation source. {gamma}-ray transmission dose was determined by GM survey meter. The liquid nitrogen level could be determined by using the change of the transmission dose with amount of liquid nitrogen. (S.Y.)
Making use of a lead slowing-down spectrometer coupled to a 46 MeV electron linear accelerator and a back-to-back type double fission chamber, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40 % full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, for which the evaluated and the experimental data were broadened by the energy resolution function of the spectrometer. (author)
Making use of a back-to-back type double fission chamber and a lead slowing-down spectrometer driven by a 46 MeV electron linear accelerator, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40 % full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, whose evaluated and measured data were broadened by the energy resolution function of the spectrometer.
Making use of a back-to-back type double fission chamber and a lead slowing-down spectrometer driven by a 46 MeV electron linear accelerator, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40% full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, whose evaluated and measured data were broadened by the energy resolution function of the spectrometer. (author)
Fe-Cr amorphous films have been formed by both in situ evaporation of multilayered films and ion beam mixing in a target chamber of a 200 keV implanter. The effects of Cr content and ion irradiation on the amorphization of films were examined by transmission electron microscope (TEM). Corrosion of film was investigated by means of a potential dynamic polarization. Corrosion resistance of amorphous film in 0.5 mol H-2SO-4 solution is considerably increased than that of pure iron. Using X ray photoelectron spectroscopy (XPS) corrosion resistance in atmosphere of amorphous Fe-Cr passive films formed by P"+ mixing was studied. Results show that the richness of Cr and P exist at the surface of Fe-Cr film.
An 80 keV, 3.6 MW neutral beam injection system has recently been installed on Doublet III, and the installation of a second system is scheduled within several months. Armor plate consisting of /approximately equals/100 graphite tiles (10 cm x 10 cm) coated with TiC has been plated over portions of the inner vacuum wall lying in the line of sight of the ion sources. In order to monitor the condition of the armor plate an infrared camera and a set of optical pyrometers have been installed alongside the beamline and view the armor plate through a CaF/sub 2/ window. The pyrometers measure the temperature of the armor plate associated with the maximum of the intensity distribution of each ion source.
It has been demonstrated that, by incorporating a thin #approx#20 nm Si_1_-_yC_y (with y as low as 0.1%) layer at the deep indium implant end-of-range (EOR) region, the EOR defects and enhanced diffusion behavior associated with indium implant can be eliminated. The Si_1_-_yC_y layer was grown epitaxially followed by a silicon epitaxy cap of 60 nm. Indium implantations were performed at 1x10"1"4 cm"-"2 at 115 keV followed by spike annealing at 1050 deg. C. The experimentally observed EOR defect and enhanced diffusion elimination are explained based on the undersaturation of implantation-induced silicon interstitials with the presence of substitutional carbon at the Si_1_-_yC_y layer.
We have simulated the transient enhanced diffusion (TED) of boron fluoride (BF_2"+) implanted in crystalline and germanium amorphized silicon. Based on recently published models, the effect of fluorine on boron diffusion in silicon has been introduced and a modelling has been suggested. In order to simulate the boron experimental profiles, we have assumed that fluorine forms clusters involving interstitial boron which reduces the junction depth. Experimental results indicate that fluorine behaviour depends on amorphization energy. Moreover, even no germanium preamorphization is performed, silicon is still amorphized by fluorine species. Hence, BF_2"+ implantation leads to an amorphous/crystalline (a/c) interface near the surface. An improvement of published models is suggested taking into account fluorine effects. The simulations satisfactory reproduce the SIMS experimental profiles for a large scale of experimental conditions.
The indium implant damage and diffusion behavior in thin silicon-on-insulator (SOI) with a 200 nm top silicon layer were studied for different implantation energies and doses. Rutherford backscattering spectrometry in the channeling mode (RBS/C) was used to characterize the implant damage before and after annealing. Secondary ion mass spectrometry (SIMS) was used to study the indium transient enhanced diffusion (TED) behavior in the top Si layer of the SOI structure. An anomalous redistribution of indium after relatively high energy (200 keV) and dose (1 x 10{sup 14} cm{sup -2}) implantation was observed in both bulk Si and SOI substrates. However, there exist differences in these two substrates that are attributable to the more predominant out-diffusion of indium as well as the influence of the buried oxide layer in the SOI structure.
The indium implant damage and diffusion behavior in thin silicon-on-insulator (SOI) with a 200 nm top silicon layer were studied for different implantation energies and doses. Rutherford backscattering spectrometry in the channeling mode (RBS/C) was used to characterize the implant damage before and after annealing. Secondary ion mass spectrometry (SIMS) was used to study the indium transient enhanced diffusion (TED) behavior in the top Si layer of the SOI structure. An anomalous redistribution of indium after relatively high energy (200 keV) and dose (1 x 10"1"4 cm"-"2) implantation was observed in both bulk Si and SOI substrates. However, there exist differences in these two substrates that are attributable to the more predominant out-diffusion of indium as well as the influence of the buried oxide layer in the SOI structure.
The g-factor of the 21/2/sup +/ state at 1921.9 keV in /sup 203/Pb has been measured through the time differential perturbed angular distribution technique in an external magnetic field B=2.028 T. The measured g-factor g=-0.063(2) indicates a predominantly three neutron hole configuration described by the wave function 0.68vertical strokei/sup -1//sub 13/2/f/sup -2//sub 5/2/>+-0.73vertical strokei/sup -1//sub 13/2/f/sup -1//sub 5/2/p/sup -1//sub 3/2/>.
Data from Monte Carlo transport codes are used to model radiobiological effects. We previously reported the Fourier analysis of ionization data generated by simulating a 500-keV proton traversing water. Here, we extend Fourier analysis to energy transfer data of another radiation type, a 14-MeV #alpha#-particle. A radiobiological model based on this frequency-domain analysis views cell as an information processing system . It lends itself naturally to traditional engineering analyses. One engineering principle-the output response of a linear system to random signal-is applied here to explain the fact that there is measurable difference in the magnitude of the biological effectiveness when a given biological system is irradiated with two different radiation types of the same Linear Energy Transfer (LET).
Focused ion beam (FIB) micromachining has been used to produce inclined planes on semiconductor surfaces. A 10 keV FIB system, utilising a Ga"+ liquid metal ion source (LMIS), was employed. The ramped surfaces were prepared by digitally deflecting the ion beam in a serpentine fashion over a rectangular area and incrementing the time the beam spends at a pixel, dwell time, line by line. For the conditions used, control in micromachining the inclination of the ramps to the starting horizontal surface is of the order of 1 arc s per scan of the FIB over the area of interest. The possibility of using such surfaces prepared by FIB, along with vacuum growth techniques such as molecular beam epitaxy (MBE), for application to strain relief structures and lateral device production is discussed. (author).
Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization then used at another site.
Isotropic Compton profiles of TaC and TaN have been measured for the first time, at an intermediate resolution, using 662 keV #gamma#-radiation. Energy bands, density of states and Fermi surface topology of TaC and TaN have been computed using linear combination of atomic orbitals with density functional theory and full potential linearised augmented plane wave method. Both band structure calculations predict the metallic character of TaC and TaN. The electron momentum densities calculated using various approaches of density functional theory are compared with the present measurements. On the basis of Mulliken's population, it is also seen that TaC has more covalent bonding than TaN. The optical properties computed using full potential linearised augmented plane wave method are explained in terms of intraband transitions.
The properties of negative-ion beams are very important for designing negative-ion apparatus and applications of negative-ion beams, especially, electron detachment cross-sections at the interaction between negative-ion beams and gas particles in the transport system, and secondary-electron emission factors when negative ions are incident on solid surfaces. These properties of negative-ion beams were investigated experimentally as a function of the ion energy under 50 keV. The single electron detachment cross-sections are almost constant in the other of 10[sup -15] cm[sup 2] in this energy range, but double electron detachment cross-sections increase in proportion to the ion velocity and much smaller than the single one. As for the secondary-electron emission factor, the emission factors for negative-ion beam are found to be larger by 1 than those for positive-ion beams. (author).
The properties of negative-ion beams are very important for designing negative-ion apparatus and applications of negative-ion beams, especially, electron detachment cross-sections at the interaction between negative-ion beams and gas particles in the transport system, and secondary-electron emission factors when negative ions are incident on solid surfaces. These properties of negative-ion beams were investigated experimentally as a function of the ion energy under 50 keV. The single electron detachment cross-sections are almost constant in the other of 10"-"1"5 cm"2 in this energy range, but double electron detachment cross-sections increase in proportion to the ion velocity and much smaller than the single one. As for the secondary-electron emission factor, the emission factors for negative-ion beam are found to be larger by 1 than those for positive-ion beams. (author).
Electrical properties of 16 keV, focused-ion-beam (FIB) (beam diameter: 1 #mu#m, current density: 50 mA/cm"2) boron-implanted silicon layers have been investigated as a function of beam scan speed and ion dose, and compared with those obtained by conventional implantation (current density: 0.4 #mu#A/cm"2). High electrical activation of the FIB implanted layers is obtained by annealing below 800"0C as a result of the increase in amorphous zones created in the implanted layers. Amorphous zone overlapping is assumed to occur at FIB implantation doses of 3 - 4 x 10"1"5 ions/cm"2 from the results of electrical activation and the carrier profile of implanted regions annealed at low temperature, if beam scan speed is lowered to about 10"-"2 cm/s. (author).
The effects of irradiation from a focused ion beam (FIB) system on MOS transistors are reported systematically for the first time. Three MOS transistor technologies, with 0.5, 1, and 3 {mu}m minimum feature sizes and with gate oxide thicknesses ranging from 11 to 50 nm, were analyzed. Significant shifts in transistor parameters (such as threshold voltage, transconductance, and mobility) were observed following irradiation with a 30 keV Ga{sup +} focused ion beam with ion doses varying by over 5 orders of magnitude. The apparent damage mechanism (which involved the creation of interface traps, oxide trapped charge, or both) and extent of damage were different for each of the three technologies investigated.
N-type crystalline Si (100) implanted with 5 keV B ions was subsequently irradiated with MeV Si, O and F ions. The B atom profiles were measured by means of secondary ion mass spectrometer after the treatment of rapid thermal annealing. The results show that the transient enhanced diffusion of B atoms is effectively limited by the post-implantation of high energy ions at high dose. At the same irradiation conditions, it is found that the existence of a SiO_2 layer in the near surface of Si is even more effective in suppressing the transient enhanced diffusion of the doped B atoms. The results are qualitatively discussed in combination with the analyses of RBS/c measurements and calculation of the DICADA code
The intermediate valent behaviour of YbPd_2Si_2 has been studied under pressure in the temperature range from 1.2 K to 90 K by using the 84 keV Moessbauer transition in "1"7"0Yb. At 54 kbar and 4.2 K we obtain an increase of the electric field gradient (EFG) by a factor of #approx =# 3. In addition, the EFG varies strongly with temperature, in contrast to the behaviour at ambient pressure. At 1.2 K a change of the hyperfine pattern is observed indicating a magnetic character of the Yb ion. These results provide evidence of a pressure induced change of the valence state close to 3+. (orig.).
Monte Carlo calculations using the codes PENELOPE and GEANT4 have been performed to characterize the dosimetric properties of monoenergetic photon point sources in water. The dose rate in water has been calculated for energies of interest in brachytherapy, ranging between 10 keV and 2 MeV. A comparison of the results obtained using the two codes with the available data calculated with other Monte Carlo codes is carried out. A chi2-like statistical test is proposed for these comparisons. PENELOPE and GEANT4 show a reasonable agreement for all energies analyzed and distances to the source larger than 1 cm. Significant differences are found at distances from the source up to 1 cm. A similar situation occurs between PENELOPE and EGS4.
Reducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the optimum peaking time for particular detector systems is important. For this purpose, pure Se and Zn elements were excited by 59.5 keV ?-rays from a 50 mCi 241Am annular radioactive source in this study. The characteristic x-rays emitted from pure Se and Zn elements were detected by using an ultra low energy Ge (Ultra-LEGe) detector connecting Tennelec TC 244 spectroscopy amplifier at different peaking time modes. Overall pulse widths were determined by HM 203-7 oscilloscope connecting amplifier. The proper peaking time for ultra low energy germanium detector (Ultra-LEGe) is determined about 4 ?s.
In this paper, the design of large thin PIN detector with a membrane stress avoidance configuration is proposed, and the related device fabrication process is developed. Ultra-thin PIN detector {approx} 1.13 cm{sup 2} in area is fabricated on a thin ( {approx} 35{mu}m) silicon membrane, and characterized. Detector performance improvement has been successfully demonstrated. With the membrane stress avoidance design, the improved detector exhibits a leakage of 6nA, which is at least 5 times lower than that of detector of identical junction area. The new detector features a full depleted capacitance of 110 pF, and a FWHM of 40.86 keV energy resolution for 5.486 MeV alpha particle spectrography.
A deep band of {l_brace}311{r_brace} defects was created 520 nm below the silicon surface with a 350 keV Si implant followed by a cluster-forming rapid thermal anneal (800 C, 1000 s). Chemical etching was used to vary the depth to the surface of the {l_brace}311{r_brace}-defect band. Afterwards, the defect dissolution was investigated at 750 C for different times. Varying the depth in this fashion assures that only the depth and no other feature of the cluster distribution is changed. The {l_brace}311{r_brace} defects were analyzed by plan-view, transmission electron microscopy. We show that the dissolution time of the {l_brace}311{r_brace}-defect band varies linearly with depth, confirming that surface recombination controls the dissolution and is consistent with analogous observations of transient enhanced diffusion.
A deep band of #left brace#311#right brace# defects was created 520 nm below the silicon surface with a 350 keV Si implant followed by a cluster-forming rapid thermal anneal (800 C, 1000 s). Chemical etching was used to vary the depth to the surface of the #left brace#311#right brace#-defect band. Afterwards, the defect dissolution was investigated at 750 C for different times. Varying the depth in this fashion assures that only the depth and no other feature of the cluster distribution is changed. The #left brace#311#right brace# defects were analyzed by plan-view, transmission electron microscopy. We show that the dissolution time of the #left brace#311#right brace#-defect band varies linearly with depth, confirming that surface recombination controls the dissolution and is consistent with analogous observations of transient enhanced diffusion.
This paper reviews various techniques to harden Charged Coupled Device (CCD) sensors and the results after irradiation of three Thomson n buried channel CCDs having a different degree of hardening. It describes the major irradiation effects on CCD performances and it makes a comparison of the results between the different hardening levels. It shows good results on dark voltage after ionizing radiation for TH 7863M device hardened both by design and by operating conditions (MPP mode) with respect to the standard device TH 7863A. The irradiations were performed with "6"0Co or X-ray (10 keV) sources on devices in operating mode. (author). 3 refs., 8 figs.
Measurements of absolute differential cross sections for H"+-H_2 direct, single-, and double-charge-transfer scattering at 0.5, 1.5, and 5.0 keV are reported at laboratory scattering angles less than 1 degree with an angular resolution of approximately 0.02 degree. The cross sections exhibit deep interference oscillations in single-charge-transfer scattering, but no such oscillations are present in direct and double-charge-transfer scattering. Theoretical cross sections derived using the diatoms-in-molecules method to describe the molecular states in a semiclassical molecular-orbital three-state close-coupling model within a semiclassical framework agree satisfactorily with the experimental results.
The effects of focused-ion-beam-induced damage on electrical properties of n-type Si are investigated by Schottky contacts. Crystalline Si is exposed to 10-30 keV focused ion beam (FIB), followed by Pt deposition under vacuum of 4x10"-"4 Pa. From current-voltage-temperature measurements, barrier heights of the Schottky contacts are found to increase almost linearly as the FIB energy increases, with the maximum increment of 0.29 eV. The increase is suggested to be related to the arising of acceptorlike defects and an amorphous layer due to FIB damages. A theoretical model is set up to quantitatively describe the barrier height changes.
Channeling effect measurements have been employed to investigate radiation damage produced by 100-keV Ar ions in preferred oriented polycrystalline metal-silicide layers, such as Pd/sub 2/Si and NiSi/sub 2/ layers formed on single-crystalline Si. For room-temperature implantation, an amount of the damage in Pd/sub 2/Si layers was found to saturate at doses between 3 x 10/sup 14/ and 1 x 10/sup 17/ ions/cm/sup 2/, where the minimum aligned yield of 1.5-MeV He ions was nearly 40% of the random one. On the contrary, it was observed that the NiSi/sub 2/ layers became amorphous at doses higher than 3 x 10/sup 15/ ions/cm/sup 2/. These results were confirmed by the reflection electron diffraction analyses.
Channeling effect measurements have been employed to investigate radiation damage produced by 100-keV Ar ions in preferred oriented polycrystalline metal-silicide layers, such as Pd_2Si and NiSi_2 layers formed on single-crystalline Si. For room-temperature implantation, an amount of the damage in Pd_2Si layers was found to saturate at doses between 3 x 10"1"4 and 1 x 10"1"7 ions/cm"2, where the minimum aligned yield of 1.5-MeV He ions was nearly 40% of the random one. On the contrary, it was observed that the NiSi_2 layers became amorphous at doses higher than 3 x 10"1"5 ions/cm"2. These results were confirmed by the reflection electron diffraction analyses.
Interest in optics for hard X-ray broad-band application is growing. In this paper, we compare the hard X-ray (20-100 keV) reflectivity obtained with an energy-dispersive reflectometer, of a standard commercial gold thin-film with that of a 600 bilayer W/Si X-ray supermirror. The reflectivity of the multilayer is found to agree extraordinarily well with theory (assuming an interface roughness of 4.5 Angstrom), while the agreement for the gold film is less, The overall performance of the supermirror is superior to that of gold, extending the band of reflection at least a factor of 2.8 beyond that of the gold, Various other design options are discussed, and we conclude that continued interest in the X-ray supermirror for broad-band hard X-ray applications is warranted.
Reducing implant energy is an effective way to eliminate transient enhanced diffusion (TED) due to excess interstitials from the implant. It is shown that TED from a fixed Si dose implanted at energies from 0.5 to 20 keV into boron doping-superlattices decreases linearly with decreasing Si ion range, virtually disappearing at sub-keV energies. However, for sub-keV B implants diffusion remains enhanced and x{sub j} is limited to {ge} 100 nm at 1,050 C. The authors term this enhancement, which arises in the presence of B atomic concentrations at the surface of {approx} 6%, Boron-Enhanced-Diffusion (BED).
A study has been made of B transient enhanced diffusion (TED) in heavily P-doped Si using secondary ion mass spectroscopy (SIMS) and positron annihilation spectroscopy (PAS). The P-doped silicon was implanted with boron ions of 40 keV energy to a dose of 3 x 10"1"4 cm"-"2, and then annealed at temperatures ranging from 700--1,000 C in a N_2 ambient for varying durations. As P doping concentration increased from 3 x 10"1"9 to 1 x 10"2"0 cm"-"3, boron diffusivity and the immobile boron fraction decreased. The experimental results are inconsistent with the predictions of the Fermi-level model and suggest that the clustering between B atoms and Si interstitials should be invoked in order to explain the immobile portion of the B peak during TED.
A 20-MeV proton accelerator is developed by Proton Engineering Frontier Project (PEFP) at Korea Atomic Energy Research Institute (KAERI). The 20MeV accelerator consists of 50keV proton injector, 3MeV RFQ (Radio frequency Quadrupole), 20MeV DTL (Drift Tube Linac) and 20MeV beam line. The beam profile was measured at the end of the 20MeV beam line with wire scanner. Moreover the beam emittance was calculated from the quad scan method using beam line quadrupole magnets. In this paper, the beam profile measurement results are presented and the emittance measurement from the quad scan method is discussed
We present results of multiple-time-scale simulations of 5, 10 and 15 keV low temperature ion implantation of arsenic on silicon (100), followed by high temperature anneals. The simulations start with a molecular dynamics (MD) calculation of the primary state of damage after 10ps. The results are then coupled to a kinetic Monte Carlo (MC) simulation of bulk defect diffusion and clustering. Dose accumulation is achieved considering that at low temperatures the damage produced in the lattice is stable. After the desired dose is accumulated, the system is annealed at 800 degrees C for several seconds. The results provide information on the evolution for the damage microstructure over macroscopic length and time scales and affords direct comparison to experimental results. We discuss the database of inputs to the MC model and how it affects the diffusion process.
Much theoretical and experimental efforts have been expended in recent years to study those atomic processes which are specially relevant to understanding high temperature laboratory plasmas. For magnetically confined fusion plasmas, the temperature range of interest spans from the hundreds of eV at plasma edges to 10 keV at the center of the plasma, where most of the impurity ions are nearly fully ionized. These highly stripped ions interact strongly with electrons in the plasma, leading to further excitation and ionization of the ions, as well as electron capture. Radiations are emitted during these processes, which easily escape to plasma container walls, thus cooling the plasma. One of the dominant modes of radiation emission has been identified with dielectronic recombination. This paper reviews this work.
Evaporated palladium films of 45 nm thickness on Si(111) were irradiated using 78 keV Ar/sup +/ ions with doses in the range of 1 x 10/sup 15/ to 1.5 x 10/sup 16/ cm/sup -2/ for the purpose of studying silicide formation. Rutherford backscattering analysis shows that intermixing has occurred across the Pd-Si interface at room temperature. The mixing behaviour increases with increasing dose of the bombarding ions, which agrees well with a theoretical model of isotropic cascade mixing for palladium, and radiation-enhanced diffusion associated with an interstitial mechanism for silicon.
Charge carrier profiles are measured for boron implanted into silicon (E = 30 keV, dose range 5 x 10"1"5 to 2 x 10"1"6 B/cm"2) after rapid isothermal annealing using halogen lamps. Maximum temperatures between 1000 and 1300 "0C and holding times at T/sub max/ of 5 and 20 s are used for the annealing treatment. In a few additional experiments flash lamp annealing at 1350 "0C (pulse duration 20 ms) is investigated. By comparison of the experimental profiles with computer simulations using the SUPREM II program transient enhanced diffusion of boron could be detected in all investigated cases. Maximum charge carrier concentrations above the equilibrium solubility of boron are observed and are discussed. (author).
This paper reports measurements of absolute differential cross sections for electron capture and loss for fast hydrogen atoms incident on H_2, N_2, O_2, Ar, and He. Cross sections have been determined in the 2.0- to 5.0-keV energy range over the laboratory angular range 0.02 degree--2 degree, with an angular resolution of 0.02 degree. The high angular resolution allows us to observe structure at small angles in some of the cross sections. Comparison of the present results with those of other authors generally shows very good agreement.
Several complex organic molecules are routinely detected in high abundances towards hot cores and hot corinos. For many of them, their paths of formation in space are uncertain, as gas phase reactions alone seem to be insufficient. In this paper, we investigate a possible solid-phase route of formation for methyl formate (HCOOCH3). We use a chemical model updated with recent results from an experiment where simulated grain surfaces were irradiated with 200 keV protons at 16 K, to simulate the effects of cosmic ray irradiation on grain surfaces. We find that this model may be sufficient to reproduce the observed methyl formate in dark clouds, but not that found in hot cores and corinos.
A new principle of particle trapping in the simple spherical cavity using both electric and magnetic components of radiofrequency electromagnetic field is proposed. The electric component of H {sub 12} oscillating mode drives the fast particle oscillations, while the magnetic component synchronously bends the trajectories to the cavity center. A specially developed theory of particle stability predicts dense and energetic electron cluster in the trap. Numerical simulations of particle dynamics in the complete electromagnetic field taking into account both space charge and particle-induced magnetic field are in good agreement with the analytic results, giving a density of 2.6*10{sup 1} electrons/cm{sup 3} and an average kinetic energy of around 30 keV at an operating frequency of 3 GHz. Being used at lower frequency, spherical cavity can trap protons and heavier ions too, but with lower density and kinetic energy.
Purpose: To evaluate the success rates of the implantation of stent grafts in the treatment of peripheral aneurysms. Materials and methods: in 13 patients with 15 aneurysms at the common iliac artery (n = 6), external iliac artery (n = 1), hypogastric artery (n = 2), femoral artery (n = 2) or popliteal artery (n = 4), implantation of dacron-covered nitinol stents was performed. The patients were followed up for three to 20 months (mean, 8.8 months) with intravenous digital subtraction angiography, CT or colour-coded Doppler sonography. Results: In all cases, the aneurysm was successfully occluded after stent implantation. In one case with a popliteal aneurysm, kinking of the vessel caused thrombosis of the stent. The stent was successfully reopened. The aneurysm however, had to be surgically treated 9 months later. The primary and secondary patency rates at 6 months were 93% and 100%, respectively. Conclusion: The method described might be an alternative therapy to surgery. There are ...
This research project aimed to determine the factors for the transfer of the elements silver (Ag), cerium (Ce), cobalt (Co), chrome (Cr), gallium (Ga), lanthanum (La), molybdenum (Mo), niobium (Nb), radium (Ra), ruthenium (Ru), antimony (sb), thorium (Th), titanium (Ti) and uranium (U) from food into the mother's milk. This factors will be used as a basic to check and derive activity values for the contamination of food and for radiation protection at working places of suckling women. For this purpose 19 mothers collected samples daily (2-8 weeks), using the duplicate method, of all the food they consumed as well as of their milk. After microwave-assisted digestion the element contents were analysed by mass-spectroscopy with inductive coupled plasma (ICP-MS). The results of the mothers who participate for more than 5 weeks were used to make a time lapse between the intake and transfer of the elements in the mothers milk visible. (orig.) [German] Ziel dieses Forschungsvorhabens ...
This feasibility study of the uve Institut fuer Technische Chemie und Umweltschutz GmbH discusses the scientific and technical fundamentals of a catalytic process for complete removal of organic pollutants (PAH, H-HC, PCB, phenols, nitro-aromatics and organometallic compounds, e.g. from polluted soil and groundwater) by thermal-catalytic cracking and conversion into simple gases. The process is based on the catalytic reaction of the hydrocarbon compounds with water vapour in the temperature range of 700-900 degrees centigrade. The resulting gas mixtures consist mainly of hydrogen, carbon monoxide, carbon dioxide and methane which can be used as fuels, e.g. for heating or in gas engines. The process is an alterntive to combustion. It is therefore well suited whenever the pollutant to be removed is already mixed with water or water vapour and wherever in-situ removal would be too great a hazard. [Deutsch] Die vorliegende Machbarkeitsstudie aus dem uve Institut fuer Technische Chemie und ...
The Deutsche Post AG is a transport company that with approximately 55,000 vehicles owns one of the biggest fleets in Europe. Being aware of its responsibility in the field of environmental policy it is looking for an alternative solution of an environmentally friendly vehicle drive system that also takes into account economic efficiency. Extensive investigations have led to a new energy storage based on the zinc-air energy system that has been developed and manufactured by the Israeli Company Electric Fuel Ltd. First tests showed an extraordinarily high capacity potential, drive values and ranges, which had been considered as impossible until that point of time. After these tests the Deutsche Post AG decided together with other well-known partners at home and abroad to carry out a territorial test with the zinc-air energy system in order to obtain insight into the day-to-day capability, economic efficiency, environmental friendliness under real driving conditions and into the required ...
Characterisation of the classification of brain tumours authorised by the WHO. Method of appraisal: This classification was revised and published in its second version. In the revision, some tumours were regrouped histogenetically and some tumour variants were added. Radiologically relevant changes of the classification include the differentiation of four new tumour entities that are easily distinguished by MR imaging. These four tumours belong to the group of childhood tumours or tumours occurring in early adulthood and are characterized by a good prognosis after extirpation. Results of appraisal: Central neurocytomas are small-cyst ventricular tumours associated with the foramen of Monroi and show moderate contrast enhancement. Infantile desmoplastic gangliogliomas/astrocytomas commonly consist of a solid tumour portion related to the leptomeninges with pronounced contrast enhancement and a typically very large cyst. Pleomorphic xanthostrocytomas are circumscribed cortical tumours ...
One part of the RWE measure catalogue in order to guarantee an environmental friendly and competitive electric power generation based on brown coal is to carry out measures improving the efficiency at existing steam turbines in RWE brown coal power plants. Since 1993 a total of 21 steam turbines with a gross capacity of 7,100 MW or net capacity of 6540 MW - this corresponds to approximately 70 % of the installed RWE brown coal power plant capacity - have been improved with an investment of approximately DM 500 million. The net block efficiency has been increased by 1.3 % on average. The planned net capacity increase of approximately 250 MW is still going to be achieved taking into account the pending enhancements. Nuclear power plant turbines have been successfully improved in the same way. Apart from the described retrofit programme measures to improve efficiency are carried out at further steam turbines of brown coal power plants. In the frame of this talk the measures taken are ...
It has been previously stated that the minimum physiological recommendations for the indispensable amino acids in health adults, as proposed by FAO/WHO/UNU in 1985, are far too low, except for the methionine. An amino acid stable isotopic kinetic study was conducted to seek further experimental support to this hypothesis. Twenty healthy young men received an l-amino acid based diet, supplying 140 mg N.kg"-"1.d"-"1, patterned on egg protein for 1 week, then for 3 weeks either i) a pattern based on current international recommendations (FAO diet, n=7), ii) a the tentative Laboratory of Human Nutrition of the Massachusetts Institute of Technology, new amino acid recommendation pattern (MIT diet, n=7) or iii) again the egg hen pattern (EGG diet, n=6). All subjects were again studied for one final, consecutive week of the egg diet. At the end of the initial week, at the first and third week with the three experimental diets,and after three days following the return of ...
Purpose: In an experimental study, the correlation between the trabecular bone density of the different regions of the proximal femur and the fracture load in the setting of femoral neck fractures was examined. Methods: The bone mineral density 41 random proximal human femora was estimated by single-energy quanitative CT (SE-QCT). The trabecular bone density was measured at the greatest possible extracortical volume at midcapital, midneck and intertrochanteric level and in the 1 cm{sup 3} volumes of the centres of these regions in a standardised 10 mm thick slice in the middle of the femoral neck axis (in mg/ml Ca-hydroxyl apatite). The proximal femora were then isolated and mounted on a compression/bending device under two-legged stand conditions and loaded up to the point when a femoral neck fracture occurred. Results: Statistical analysis revealed a linear correlation between the trabecular bone density and the fracture load for the greater regions, with the highest value in the ...
Primary malignant lymphoma of the brain is a disease of unknown etiology, which is increasing in incidence and has an unfavorable prognosis. Despite the lack of specific changes on CT or MRI in most cases, these procedures may typically facilitate the diagnosis: A focal-enhancing mass with subependymal spread on CT or MRI and hyperattenuation on nonenhanced CT are the most reliable features in the diagnosis of primary malignant lymphoma of the brain. Peritumoral edema and mass effect are usually not prominent features. On unenhanced CT scans they usually appear homogeneously isodense to mildly hyperdense relative to the gray matter. On MRI these tumors are slightly hypointense on T1-weighted images and slightly hpyerintense on PD- and T2-weighted images relative to the gray matter. On CT and MRI enhancement is usually homogeneous. Contrast-enhanced MRI, with its multiplanar capability, lack of bone-induced artifacts, and high-contrast resolution, is likely to reveal subependymal spread ...
60 patients between 17 and 72 years of age were investigated. First, an enteroclysis was performed in typical manner. The applicated methylcellulosis was blended with positive oral MR contrast media (Magnevist oral, Schering). After enteroclysis, MRI of the abdomen was performed using T1- and T2-weighted breathhold sequences (Flash 2D pre- and postcontrast and TSE) in axial and coronal planes. The length of the affected bowel and the stenosis seen with enteroclysis correlated well with the visible thickening of the small bowel wall and the stenosis seen in MRI. Using MRI, additional findings could be obtained in 28 patients, such as fistulas, abscesses or a hydronephrosis, or a better assessment of the stenosis was possible with MRI, because of the avoidance of overshadowing of the affected bowel loop with MRI. A brilliant MR-tomographic imaging of the small bowel is possible under the condition, that the small bowel contrast is optimal. The main prerequisite is a large filling volume ...
Clinical studies have proved the effectiveness of local ablading methods in pations with non-resectable liver metastases of a colorectal carcinoma. RF ablation and LITT are a potentially curative therapy option and an alternative to systemic chemotherapy; the latter is carried out primarily for reducing tumour size with the goal of secondary resectability. The number of R0-sesectable metastases can be enhanced by a combined therapy of surgery and local ablading methods, e.g. by preoperative, intraoperative or postoperative ablasion of further non-resectable tumours during surgery. Systemic chemotherapy combined with surgery as an adjuvant method is not recommended unless in cases of non-abladable tumour recidivation. Currently, systemic chemotherapy is used as a neo-adjuvant therapy for tumour size reduction with the goal of secondary resectability or, in case of inoperability, local ablation. (orig.) [German] Abladierende Verfahren. Klinische Studien belegen die Effektivitaet der ...
Parallel imaging and echo sharing techniques have markedly reduced the acquisition times for MRI of large volumes. Dynamic 2 and 3-dimensional data sets of the chest with high temporal resolution (up to 10 images/s with single slice and 2 volume/s) allow an analysis of respiratory motion of the lungs and tumors. Time-resolved 2D series in preselected planes can be used to observe respiratory motion during free breathing or after respiratory commands, e.g. to exclude chest wall invasion by a tumor or for diagnosing impairment of respiratory mechanics. Time-resolved 3D-series (4D-MRI) allow monitoring of the spatial displacement of the lungs and tumors as a whole volume. Present limitations such as an overestimation of tumor size and an underestimation of displacement due to a limited temporal resolution are expected to be overcome with further technical developments. However, 4D-MRI already appears to be the appropriate tool to select patients for motion-adapted radiotherapy. In ...
This thesis deals with the analysis of dominant loss mechanisms in direct methanol fuel cells (DMFC) and hydrogen fed polymer electrolyte membrane fuel cells (PEFC) by means of experimental characterization and modeling work. Due to different fuels used in these two fuel cell types, the dominant loss mechanisms are different in their nature. All in-situ characterization techniques that are used in this work are based on a novel test fuel cell with embedded reference electrodes. The first part of this work presents a new concept for realizing a reference electrode configuration in a polymer electrolyte membrane fuel cell by means of laser ablation. The laser beam is used to evaporate a small gap into the electrode surface of a catalyst coated membrane (CCM) to isolate the reference electrode from the working/counter electrode (WE/CE). This method enables the simultaneous ablation of the electrodes on both sides of the CCM because the membrane is transparent for the laser beam. ...
Tribological performance of alumina and silicon carbide ceramics as well as of the hardened steel 100Cr6 for reference was studied during reciprocating sliding and cavitation erosion in isooctane as substitute of gasoline and in distilled water. It was the aim to characterize effects of surface finish of the specimens and the liquid media on friction, resistance to sliding wear and cavitation erosion. Sliding wear tests were run on the self-mated ceramics and ceramic/steel pairs under conditions of boundary lubrication using a laboratory tribometer with cylinder-on-plate geometry. Vibratory cavitation erosion tests were conducted according to ASTM G 32-92. High initial surface roughness of coarse ground specimens led to a distinct running-in period during sliding contact with a transition from high to low values of friction coefficient and wear intensity. Incubation time was reduced with increasing surface roughness in the cavitation tests. Depending on the materials investigated, the ...
Aim: The purpose of this prospective study was to evaluate the value of immunoscintigraphy (ISG) with anti-225.28S in clinically suspected ocular melanoma. Methods: For this purpose standardized ISG was performed in 36 patients using both planar acquisition and emission computed tomography (ECT). Ocular melanoma was present in 31 patients. In 21 patients therapy was enucleation of the eye. These specimens were evaluated by histology and immunohistochemistry in 11 of 21 patients. Results: Regarding the clinical diagnosis, ISG was positive only in 15 of 31 patients with ocular melanoma, regarding histology in 11 of 21 and regarding immunohistochemistry in 5 of 6 patients with a positive immunoreaction. 5 patients showed no immunoreactivity, their ISG was negative. Conclusion: Thus a good correlation between ISG and immunohistochemistry was observed. However ISG using the cutaneous melanoma antibody 225.28S cannot be recommended for the diagnostic work-up of an ocular melanoma considering ...
To determined precisely a possible connection between the amount of copper in tap-water and the risk of early childhood liver disease, it was attempted through an epidemiological survey, to determine the extent of excessive concentrations of copper in the tap-water of households with copper pipes. Water samples from 956 households were tested for copper, and the state of health of the infants in these households was documented. Infants who had been fed using water with a copper concentration of 0.8 mg/l or more received a paediatric examination with a blood serum analysis to rule out any liver damage. A copper level greater than 0.8 mg/l was found in only 2% of the households examined. Eight infants were examined by a paediatrician and their serum was analysed. These infants had either been breast-fed to the 12th week or had received more than 200 ml of tap water per day during first 12 months. None of the infants examined showed any signs of liver malfunction. From the results of the ...
We performed a comparative study of digitally and conventionally acquired images in gastrointestinal examinations. Radiation dose and spatial resolution were determined in a water phantom. In 676 examinations with either conventional or digital imaging (system: Diagnost 76, DSI) the number of images and the duration of the fluoroscopy time were compared. 101 examinations with digital as well as conventional documentation were evaluated by using 5 criteria describing the diagnostic performance. The entrance dose of the DSI is 12% to 36% of the film/screen system and the spatial resolution of the DSI may be better than that of a film/screen system with a speed of 200. The fluoroscopy time shows no significant difference between DSI and the film/screen technique. In 2 of 4 examination modes significantly more images were produced by the DSI. With exception of the criterion of edge sharpness, DSI yields a significantly inferior assessment compared with the film/screen technique. (orig./MG) ...
CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey on CT practice. Three different application modules offer free and standardized dose calculations as well as a comprehensive benchmarking section including guidance on dose optimization. The program is ...
The use of high-performance ion exchangers allows a trace-matrix-separation (SMT) directly followed by an ion chromatographic (IC) separation of the analytes. Based on the principles described in Part 1, a combined procedure IC-SMT-IC for metallic impurities in Mo and W is presented. Up to 12 metal traces (Fe, Cu, Pb, Zn, Ni, Co, Cd, Ca, Mn, Sr, Mg and Ba) can be determined in one run with 35 min. A special method for traces of U and Th is also given. Detection limits are typically 10-100 ng g{sup -1} in the metal sample. (author). 14 refs.; 10 figs.; 6 tabs.
There are no 'intelligent' buildings but only 'intelligently controlled' buildings. Intelligent control requires communication between technical facilities, which in turn requires building automation and system integration. [German] Es gibt keine ''intelligenten'', sondern nur ''intelligent betriebene'' Gebaeude. Mit dieser Feststellung ist die Vorbedingung festgelegt, dass Gebaeude ein gewerkeuebergreifendes System benoetigen, das die Komponenten miteinander kommunizieren laesst. Dafuer eignet sich die Gebaeudeautomation. Damit diese ihre Aufgaben erfuellen kann, bedarf es der Systemintegration. (orig.)
An attempt is made to induce in mud crab (Scylla serrata) epileptiform activities that resemble the generalized epileptic seizures. Cerebral ganglion of crab was exposed in situ, to a convulsant drug pentylenetetrazole (PTZ) 100?mM, for induction of seizures. Also, crabs were pretreated with antiepileptic drug viz sodium valproate (120??mol/l) to inhibit epileptiform activities. The surface electrical discharges of cerebral ganglion were recorded using Unkelscope (MIT, USA) in control as well as experimental animals. The cerebral ganglion of crab showed a pattern of high cerebral electrical discharges after PTZ treatment compared to control. The sodium valproate promoted sedative action in control and prevented PTZ-mediated epileptiform discharges. Glutamate and GABA contents in cerebral g...
Zusammenfassung Hintergrund Endograftimplantationen im oder am Aortenbogen stellen besondere Herausforderungen an die Implantationstechnik und an die mechanischen Eigenschaften von Stentgrafts und ihren Einf?hrungssystemen, bedingt durch die Notwendigkeit, die Prothesen punktgenau abzusetzen und durch die mit der Biegung im Aortenbogen zunehmende Reibungswiderst?nde innerhalb der Einf?hrungssysteme. Die Endograftsysteme der 1. Generation (Talent?, Zenith TX 1?, TAG?) zeigten in dieser Lokalisation technisch bedingte Limitationen. Neue Prothesen Bei den seit 2004 und 2005 verf?gbaren neuen Stentgrafts (E-vita?, Zenith TX 2?, Valiant?, Relay?) sind diese Limitationen weitgehend ?berwunden. Durch technische Verbesserungen von Stentgrafts und Einf?hrungssystemen ist es nun m?glich, auch lange ...
Liberalization and the associated necessity of providing, where possible, inexpensive electrical energy, has intensified still further the demand for higher efficiency steam turbines. Accordingly, continuous efforts are being taken to improve all the flow guiding components of a steam turbine. Special attention is given here to the blading. (orig.) [Deutsch] Die Liberalisierung und die damit verbundene Notwendigkeit, elektrische Energie moeglichst preisguenstig zur Verfuegung zu stellen, hat die Forderung nach hohen Wirkungsgraden von Dampfturbinen weiter verschaerft. Es werden daher kontinuierlich Anstrengungen unternommen, alle stroemungsfuehrenden Teile einer Dampfturbine zu verbessern. Das Hauptaugenmerk gilt dabei der Beschaufelung. (orig.)
Purpose: An animal model is used to investigate whether MR angiography combined with super-paramagnetic particles of iron oxide (SPIO) is suitable for detecting thromboses. Methods: 42 rats in groups of 7 each were examined on days 1, 3, 5, 7, 9 and 11, respectively, after mechanical/chemical thrombus induction in a 1.5 Tesla magnet with a FISP sequence (TR/TE/FA 50 ms/6 ms/40 ). Imaging was performed before and up to 90 minutes after intravenous injection of 30 {mu}mol FE/kg BW of the experimental SPIO (hydrodynamic diameter, 34{+-}17 nm LLS; R1 and R2 relaxivity at 0.47 T, 31 and 57 L/(mmol*s)). MIP reconstructions of MR angiographies were submitted to consensus assessment by two examiners using histology as the gold standard. Results: The image quality of MIP reconstructions was rated as good in 38 of 42 cases. With regard to thrombotic vessel occlusion, MR angiography coincided with histology in 17 of 42 cases and differed in 25, lumen narrowing being overestimated by MRI in 4 ...
The present paper describes the application of the commercial CFD-code FLUENT 6.1 to the numerical simulation of the flow field in a high specific speed radial fan. Two-dimensional as well as three-dimensional computations are performed using the steady 'Frozen-Rotor method' as well as the unsteady 'Sliding-Mesh method'. The predicted performance curves of the radial fan are compared with the results obtained from measurements on a test stand. Due to the relatively low computation times, the 'Frozen-Rotor method' can be used routinely for design purposes. The results of this approach can be improved if the leakage flow through the gap between the inlet nozzle and the impeller is taken into account. (orig.)
Better quality of thermal comfort as well as reduced heat energy demand and accordingly CO{sub 2} emission can be achieved by better heating and ventilation strategies in private buildings. The paper deals with a novel model-based measurement and automation system. It describes the implementation of better strategies under given technical circumstances. (orig.) [German] Durch Verbesserung der Heizungs- und Lueftungsstrategien im privaten Lebensbereich kann sowohl Heizenergie eingespart und damit die CO{sub 2}-Emission verringert, als auch die Raumbehaglichkeit verbessert werden. Der Beitrag behandelt ein modellgestuetztes Mess- und Automatisierungssystem, mit dem die Realisierung der verbesserten Strategien unter gegebenen technischen Randbedingungen praktisch erst moeglich wird. (orig.)
Aim: Changes within the brain detected by MRI after chronic manganese poisoning raised the question whether morphological changes of the basal ganglia, particularly of the globus pallidus, could be detected after chronic occupational exposure to manganese dioxide. Results: No cases of parkinsonism were detected in clinical examinations or by other means. The mean manganese concentration in blood was 12 {mu}g/l (range: 3.9-23.3 {mu}g/l). In comparison to the upper reference value of 10 {mu}g/l, 42 workers (56%) had a higher body burden. A significant positive correlation between manganese levels in blood and the PI (indicated by T{sub 1}-shortening) was observed as well as between the CBI and workplace-specific exposure. Brain atrophy was not detected in any of the observed cases. Conclusions: Long-term exposure to manganese dioxide dust correlates with the Pallidum-Index in MRI scans. Although the MRI findings have no current clinical relevance for individuals, further studies are ...
Patients with haemarthros of the knee were examined by MRI and arthroscopy to identify the bleeding source and to determine surgical or conservative therapy. A prospective study was performed on 120 patients who underwent MRI and arthroscopy, point lesions and bleeding sources were documented separately on a standardised form. Arthroscopy demonstrated a ruptured anterior cruciate ligament in 86%, meniscal tears in 55%, disruption of collateral ligaments in 17%, osteochondral lesions in 5% and tears of capsule or plicae in 13%. Disruption of cruciate ligaments caused haemorrhage in all but three cases. In contrast, only meniscal tears located very adjacent to the meniscal basement had bled. Those types of osteochondral lesions caused haemorrhage characterised on MRI by destruction of the subchondral plate and overlying cartilage. Severe lesions of the knee were diagnosed by MRI in 71% to 100%, slight lesions in 13% to 40% of the cases. Single, combined and bland lesions were accurately ...
Zusammenfassung Hintergrund Seit 2005 finden schriftliche Anfragen und Vor-Ort-Pr?fungen durch den Medizinischen Dienst der Krankenversicherungen (MDK) statt. Diese spiegeln in ihren Ver?nderungen sowohl die Erfahrung der Kassen mit dem G-DRG-System (G-DRG German Diagnosis Related Groups) als auch der zust?ndigen ?rztlichen Mitarbeiter und des Krankenhauscontrollings wider. Wir wollten aufarbeiten, welche Entwicklung die MDK-Pr?fungen seit 2005 genommen haben. Hierf?r wurden s?mtliche Pr?fberichte seit Einf?hrung der Pr?fungen ausgewertet. Ergebnisse W?hrend anfangs haupts?chlich Fragen zur Kodier- und Dokumentationsqualit?t erfolgten, werden jetzt ?berwiegend Fehlbelegungspr?fungen durchgef?hrt. Zwischenzeitlich wurden konsequent die unterschiedlichen Klinikbereiche gepr?ft. Die Anfragen ...
This publication contains the Ordinance on Heating Costs, the Ordinance on Heating Installations, and the 1st Federal Ordinance on Emission Control (BImSchV) concerning Small-Scale Furnaces, in each case with notes and explanations. All these ordinances aim at reducing energy consumption in connection with heating; the 1st BImSchV also at air pollution abatement by lowering the permissible limiting values for soot and flue gas. The three ordinances also apply to housing property. (HSCH).
More than 200 years after the birth of the steam engine, the first thermal engine ever invented, thermal engines such as steam turbines, gas turbines or internal combustion engines are still driving most generators for electric power generation, most machines, and most vehicles, and this will remain so until far into the next century. (orig.) [Deutsch] Mit Waermekraftmaschinen wie Dampfturbinen, Gasturinen und Verbrennungsmotoren werden auch heute - mehr als 200 Jahre nach der technischen Reife der Dampfmaschine (der ersten Waermekraftmaschine) - die meisten Generatoren zur Stromerzeugung, die meisten Arbeitsmaschinen und die meisten Fahrzeuge angetrieben. Und dabei wird es auch bis weit in das 21. Jahrhundert bleiben. (orig.)
Smart metering is required by the EU and will be implemented in Germany during the next few years, but customers are not much interested in ''intelligent meters''. Displays and information services may ensure higher acceptance and additional use and provide an incentive for saving energy. In a pilot programme in BAvaria, Eon tested the customers' reaction to such a system. Smart metering technology and long-wave services were combined into an overall system that helps customers save energy. (orig.)
The early diagnosis of such disorders is of major importance because, in most cases, severe consequences can only be averted by early treatment. The value of magnetic resonance imaging (MRI) in many orthopaedic and traumatological conditions is generally accepted. The value of MRI in this particular field is illustrated by typical case reports on common clinical problems [Deutsch] Der Fruehdiagnose von Erkrankungen des Kindes- und Jugendalters kommt grosse Bedeutung zu, da oftmals nur durch eine daraus resultierende Fruehbehandlung schwerwiegende Folgen vermieden werden koennen. Die Kernspintomographie (Magnetresonanztomographie=MRT) ist in zahlreichen orthopaedischen-traumatologischen Fragestellungen bereits etabliert. An ausgewaehlten Fallbeispielen haeufiger klinischer Problemstellungen soll in der vorliegenden Arbeit der Stellenwert der MRT dargestellt werden. (orig.)
MRT is able to demonstrate arteries while MR angiography can quantify blood flow by a non-invasive method. In the present paper blood flow measurements were carried out in four selected cases on the basis of phase mapping. In 3 patients with lesions in the pelvis or thigh, angiography was performed in order to localise the stenosis or occlusion and this was followed by qantitative blood flow measurements. The results showed that angiography may not always provide all necessary information concerning a haemodynamically significant stenosis. The method may also be used for quantifying blood flow in the renal arteries and that it has significant advantages over the colour Doppler method. (orig.).
This conference report contains the lectures presented at the BMBF status seminar on the cooperative project ``Bodies of landfills``, which took place at Wuppertal on 25th and 26th April 1995. The cooperative project was started in autumn 1993 and studies the long-term behaviour of wastes deposited at landfills in general. Inorganic and municipal wastes are studied separately. (orig./SR) [Deutsch] Der vorliegende Tagungsband enthaelt die Vortraege des BMBF-Statusseminars zum Verbundvorhaben `Deponiekoerper` vom 25. und 26. April 1995 in Wuppertal. Das Verbundvorhaben `Deponiekoerper` wurde im Herbst 1993 begonnen und befasst sich ganz generell mit dem langfristigen Deponieverhalten von Abfaellen. Es ist unterteilt in die Untersuchung von anorganischen Abfaellen und von Siedlungsabfaellen. (orig./SR)
Trapezblechstege im Bruckenbau kommen trotz der groen Vorteile, die diese Bauweise bietet, in Deutschland bisher nur an einem Pilotprojekt zur Anwendung. Durch die charakteristischen Eigenschaften des Trapezbleches entstehen konstruktive und wirtschaftliche Vorteile gegenuber herkommlichen Bruckenbauweisen. Allerdings lassen die aktuell gultigen Regelwerke aufgrund fehlender Kenntnis zum Tragverhalten und mangelnder Erfahrung keine wirtschaftliche Ausbildung zu. Dies zeigt sich am Beispiel des Pilotprojekts. Die Ausbildung der Verbundfuge wurde hier nur sehr unbefriedigend gelost und verdeutlicht somit die Notwendigkeit einfacher und praktikabler Verbindungsmoglichkeiten. Am Institut fur Leichtbau Entwerfen und Konstruieren der Universitat Stuttgart wurde in Zusammenarbeit mit dem Institut...
The Open Software Foundation`s Distributed Computing Environment (OSF/DCE) was originally designed to provide a secure environment for distributed applications. By combining it with Kerberos Version 5 from MIT, it can be extended to provide network security as well. This combination can be used to build both an inter and intra organizational infrastructure while providing single sign-on for the user with overall improved security. The ESnet community of the Department of Energy is building just such an infrastructure. ESnet has modified these systems to improve their interoperability, while encouraging the developers to incorporate these changes and work more closely together to continue to improve the interoperability. The success of this infrastructure depends on its flexibility to meet the needs of many applications and network security requirements. The open nature of Kerberos, combined with the vendor support of OSF/DCE, provides the infrastructure for today ...
Iron nickel chromium manganese silicon and iron chromium nickel manganese silicon molybdenum niobium alloys have a so-called duplex structure in a wide concentration range. This causes an excellent resistance to wear superior in the case of adhesive stress with optimized concentrations of manganese, silicon, molybdenum and niobium. The materials can be used for welded armouring structures wherever cobalt and boron-containing alloy systems are not permissible, e.g. in nuclear science. Within the framework of pre-investigations for manufacturing of filling wire electrodes, cast test pieces were set up with duplex structure, and their wear behavior was examined. (orig.).
The ARE progress report discusses the following issues: Economic development and its effects on power supply; Deregulation of the electricity and gas market; Competition between regional utilities; Energy policy of the new German government; European regulations; Legislation on energy supply; Energy supply and cartel law; Regional supply in the East German states. [German] Der Taetigkeitsbericht der ARE befasst sich mit folgenden Themen: Gesamtwirtschaftliche Entwicklung und ihre Auswirkung auf die Energiewirtschaft, Oeffnung des Monopoles fuer Strom und Gas, Wettbewerb der regionalen Energieversorger, Energiepolitik der neuen Bundesregierung, Europaeische Richtlininen, energiewirtschaftsrecht, Versorgungswirtschaft und Kartellrecht und der Regionalversorgung in den neuen Bundeslaendern.
There are alarming scenarios that state that global heating caused by anthropogenic gaseous emissions will melt the ice caps of Greenland and the Antarctic. This would cause flooding of coastal regions on a global scale. The floods are expected already in the next century, but there are no realistic assessments of the extent of the danger. (orig.) [Deutsch] Alarmierenden Szenarien zufolge koennten durch eine globale Erwaermung, die der Mensch mit dem Ausstoss von Treibhausgasen in die Atmosphaere verursacht, die Eiskappen auf der Antarktis und Groenland abschmelzen. Schon im kommenden Jahrhundert wuerden dadurch weite kuestennahe Gebiete ueberflutet. Noch aber laesst sich schwer abschaetzen, wie real die Gefahr ist. (orig.)