WorldWideScience
1

Nanoporous structure formations on germanium surfaces by focused ion beam irradiations  

International Nuclear Information System (INIS)

The formation of porous structures of nanometre size (nanoporous structures) on germanium (Ge) surfaces by focused ion beam (FIB) irradiations was investigated using various FIB conditions such as ion species, irradiation energies, total fluences, fluence rates, and incident angles. FIB-irradiated regions were observed using a scanning electron microscope and an atomic force microscope. It is found that, using a focused Ga ion beam (Ga FIB) at an energy of 100 keV, the irradiated Ge surface swelled up to ion fluence of 2 x 10"1"7 cm"-"2 with nanoporous structures and then was etched for larger fluences. The shape of swollen nanoporous structures depended on the fluence rate and the incident angle of the Ga FIB. However, such porous structures were observed neither for low-energy (15-30 keV) FIB irradiations using Si and ...

2007-11-07

2

The study of the ion beam induced swelling in crystalline germanium irradiated by a 30 keV Ga"+ focused ion beam  

International Nuclear Information System (INIS)

The effect of swelling of crystalline Ge irradiated at room temperature with 30 keV Ga"+ focused ion beam (FIB) was studied by means of in situ FIB imaging, atomic force microscopy (AFM) and transmission electron microscopy (TEM). The swelling occurred in the surface region of amorphous damage layer which was formed during ion irradiation. The degree of swelling reaches values up to 10 times for an implantation dose of #approx#10"1"7 ions/cm"2. Cross-secitonal TEM examination showed that the swelling is due to formation of a porous layer with a honeycomb structure. (author). 8 refs., 4 figs.

2005-11-20

4

Chemical effects on L_#gamma#_1/L_#beta#_1 x-ray intensity ratio of molybdenum compounds  

International Nuclear Information System (INIS)

Chemical effects on the intensity ratio of LX-ray of molybdenum compounds irradiated by 11-keV electrons and by 3-MeV protons were studied using an x-ray crystal spectrometer. It was found that the intensity ratios of L_#gamma#_1/L_#beta#_1 markedly decrease with the increase of ionicity of molybdenum compounds, except for the case of metallic molybdenum. (author).

1987-06-01

5

Fluence- and exposure-to-dose conversion for human whole-body gamma irradiation  

International Nuclear Information System (INIS)

... kev range 10-100 kev range 100-1000 man mev range 01-10 personnel

1978-01-01

6

The influence of target backing on ion-beam electron spectra  

International Nuclear Information System (INIS)

Several different aspects of the influence of the target backing on in-beam electron spectra following compound nuclear reactions induced by accelerated ions at tandem energies irradiating backed targets are discussed in detail. This discussion is illustrated by a few typical examples, such as "1"2C"5"+ and "3"1P"1"0"+ beams at 4 MeV/u bombarding Sn(+Be), Sn(+Au), Pb(+C) backed targets. Moreover, the relative influence of electron backscattering, electron Doppler shift and Doppler broadening as well as #delta#-electron emission on the low energy electron spectra (E_e#<=#100 keV) obtained under such conditions are investigated in the frame of the available experimental data. (orig.).

7

Direct patterning of gold oxide thin films by focused ion-beam irradiation  

International Nuclear Information System (INIS)

For direct writing of electrically conducting connections and areas into insulating gold oxide thin films a scanning Ar"+ laser beam and a 30 keV Ga"+ focused ion beam (FIB) have been used. The gold oxide films are prepared by magnetron sputtering under argon/oxygen plasma. The patterning of larger areas (dimension 10-100 #mu#m) has been carried out with the laser beam by local heating of the selected area above the decomposition temperature of AuO_x(130-150 C). For smaller dimensions (100 nm to 10 #mu#m) the FIB irradiation could be used. With both complementary methods a reduction of the sheet resistance by 6-7 orders of magnitude has been achieved in the irradiated regions (e.g. with FIB irradiation from 1.5 x 10"7#OMEGA#/#square# to approximately 6 #OMEGA#/#square#). The energy-dispersive X-ray analysis (EDX) show a considerably reduced oxygen content in the irradiated areas, ...

2000-09-01

8

Triple ion-beam studies of radiation damage effects in a 316LN austenitic alloy for a high power spallation neutron source  

Energy Technology Data Exchange (ETDEWEB)

Austenitic 316LN alloy was ion-irradiated using the unique Triple Ion Beam Facility (TIF) at ORNL to investigate radiation damage effects relevant to spallation neutron sources. The TIF was used to simulate significant features of GeV proton irradiation effects in spallation neutron source target materials by producing displacement damage while simultaneously injecting helium and hydrogen at appropriately high gas/dpa ratios. Irradiations were carried out at 80, 200, and 350 C using 3.5 MeV Fe{sup ++}, 360 keV He{sup +}, and 180 keV H{sup +} to accumulate 50 dpa by Fe, 10,000 appm of He, and 50,000 appm of H. Irradiations were also carried out at 200 C in single and dual ion beam modes. The specific ion energies were chosen to maximize the damage and the gas accumulation at a depth of {approximately} 1 {micro}m. Variations in microstructure and hardness of ...

1997-09-01

9

Grain boundary transport in x-ray irradiated polycrystalline diamond  

International Nuclear Information System (INIS)

The transport properties of a 'thin' polycrystalline diamond film are analyzed after the sample exposure to 8.06-keV x-ray radiation. Structure and morphology of the as-grown film have been evaluated by Raman, x-ray diffraction, and scanning electron microscopy techniques. The transport properties have been investigated by measuring dark current-voltage characteristics in the temperature range of 60 to 360 K. Ohmic transport has been evidenced on the as-grown film up to 1.16x10"5 V/cm. After irradiation, nonlinear contributions to the dark current have been evidenced and related to field-assisted thermal ionization of traps. Below 200 K, hopping mechanisms have been observed. Correlations have been found among x-ray irradiation, density of traps involved in the transport processes, and the nonhomogeneous nature of the sample. A simple model of the grain boundary structure is proposed to explain the ...

2003-05-15

10

Investigation on corrosion resistance of amorphous films prepared by ion beam mixing  

International Nuclear Information System (INIS)

Fe-Cr amorphous films have been formed by both in situ evaporation of multilayered films and ion beam mixing in a target chamber of a 200 keV implanter. The effects of Cr content and ion irradiation on the amorphization of films were examined by transmission electron microscope (TEM). Corrosion of film was investigated by means of a potential dynamic polarization. Corrosion resistance of amorphous film in 0.5 mol H-2SO-4 solution is considerably increased than that of pure iron. Using X ray photoelectron spectroscopy (XPS) corrosion resistance in atmosphere of amorphous Fe-Cr passive films formed by P"+ mixing was studied. Results show that the richness of Cr and P exist at the surface of Fe-Cr film.

1991-01-01

11

Comparison of enhanced device response and predicted x-ray dose enhancement effects on MOS oxides  

Energy Technology Data Exchange (ETDEWEB)

The response of MOS capacitors to low- and medium-energy x-ray irradiation is investigated as a function of gate material (TaSi or Al), oxide thickness, and electric field. Measured device response is compared with predictions based on discrete ordinates and Monte Carlo code simulations of dose enhancement effects, coupled with recent estimates of electron-hole recombination in MOS oxides. In comparisons of 10-keV x-ray and Co-60 irradiations of Al-gate MOS capacitors at an oxide electric field of 1 MV/cm, it is found that predictions and experiments agree to within better than 20 percent for oxide thicknesses ranging from 35 to 1060 nm. For capacitors having TaSi/Al gates, predictions and experiments agree to within better than 30 percent at 1 MV/cm, with the largest differences occurring for 35-nm gate oxides. At other electric fields, the disagreement between experiment and prediction increases ...

1988-12-01

12

Comparison of enhanced device response and predicted x-ray dose enhancement effects on MOS oxides  

International Nuclear Information System (INIS)

The response of MOS capacitors to low- and medium-energy x-ray irradiation is investigated as a function of gate material (TaSi or Al), oxide thickness, and electric field. Measured device response is compared with predictions based on discrete ordinates and Monte Carlo code simulations of dose enhancement effects, coupled with recent estimates of electron-hole recombination in MOS oxides. In comparisons of 10-keV x-ray and Co-60 irradiations of Al-gate MOS capacitors at an oxide electric field of 1 MV/cm, it is found that predictions and experiments agree to within better than 20 percent for oxide thicknesses ranging from 35 to 1060 nm. For capacitors having TaSi/Al gates, predictions and experiments agree to within better than 30 percent at 1 MV/cm, with the largest differences occurring for 35-nm gate oxides. At other electric fields, the disagreement between experiment and prediction increases ...

1988-07-12

13

Microstructural observation of focused ion beam modification of Ni silicides/Si thin films  

International Nuclear Information System (INIS)

Focused ion beam (FIB) irradiation of a thin Ni_2Si layer deposited on a Si substrate was carried out and studied using an in-situ transmission electron microscope (in-situ TEM). Square areas on sides of 4 by 4 and 9 by 9 microm were patterned at room temperature with a 25 keV Ga"+-FIB attached to the TEM. The structural changes of the films indicate a uniform milling, sputtering of the Ni_2Si layer and the damage introducing to the Si substrate. Annealing at 673 K results in the change of the Ni_2Si layer into an epitaxial NiSi_2 layer outside the FIB irradiated area, but several precipitates appear around the treated area. Precipitates was analyzed by energy dispersive X-ray spectroscopy (EDS). Larger amount of Ni than the surrounding matrix was found in precipitates. Selected area diffraction (SAD) patterns of the precipitates and the corresponding dark field images imply the formation of a Ni rich ...

1996-12-02

14

Electron capture decay of sup 203 Pb  

Energy Technology Data Exchange (ETDEWEB)

Intensities of {gamma}-transitions emerging from the EC decay of {sup 203}Pb were measured precisely. The obtained relative {gamma}-intensities are 100%(279.2keV), 4.14+-0.08%(401.3keV) and 0.932+-0.022%(680.5keV). The 279.2 and 680.5keV level feeding {beta}-branching ratios were deduced to be 95.3+-0.1 and 4.7+-0.1% respectively. {sup 203}Pb is suggested for calibration purposes. (author).

1989-01-01

15

EB-curing of coatings on wood composite boards  

International Nuclear Information System (INIS)

The industrial radiation processing using low energy electron beam (EB) accelerators lower than 300 keV offers high speed, safe technologies for the chemical conversion of thin layer coatings. Because of the nonselective mode of initiating chain reaction polymerization involving free radicals in synthetic coating layers and suitable substrates, the EB curing of the coatings on woods and papers has particular advantage. Hungary decided to start an up-to-date EB line to process cement-bound (CB) wood chipboards with pigmented acrylic coatings. The CB wood chipboards contain more than 60 % of portland cement and up to 40 % of wood particles. They are produced as large boads of 6 - 16 mm thickness. In their fireproof character and other aspects, they are similar to asbestos-cement boards without containing carcinagenic asbestos, and are stable against moisture and atmospheric influences. EB-cured acrylate coating improved further those properties, ...

1988-10-01

16

Electron Flux - 8.0 keV - ISWA wiki - ISWA - NASA  

Science.gov (United States)

Nov 14, 2009 ... Ring Current electrons from the Fok Ring Current Model are computed using plasma and magnetic field values from the SWMF magnetosphere ...

17

Electron Flux - 4.7 keV - ISWA wiki - NASA  

Science.gov (United States)

Nov 14, 2009 ... Ring Current electrons from the Fok Ring Current Model are computed using plasma and magnetic field values from the SWMF magnetosphere ...

18

Electron Flux - 179 keV - ISWA wiki - ISWA - NASA  

Science.gov (United States)

Nov 14, 2009 ... Ring Current electrons from the Fok Ring Current Model are computed using plasma and magnetic field values from the SWMF magnetosphere ...

19

Electron collisional detachment processes for a 250 keV D/sup -/ ion beam in a partially ionized hydrogen target  

Energy Technology Data Exchange (ETDEWEB)

Neutral atom beams with energies above 200 keV may be required for various purposes in magnetic fusion devices following TFTR, JET and MFTF-B. These beams can be produced much more efficiently by electron detachment from negative ion beams than by electron capture by positive ions. We have investigated the efficiency with which such neutral atoms can be produced by electron detachment in partially ionized hydrogen plasma neutralizers.

1980-09-01

20

Dislocation pinning in electron-irradiated copper as a function of electron energy and irradiation  

Science.gov (United States)

Dislocation priming measurements were performed in the kHz range in ASARCO copper. The samples and irradiation facilities are constructed so as to allow successive irradiation of samples both with electrons and gamma rays. The gamma rays were produced by stopping 2.8-MeV electrons in a gold target. The change of the type of irradiation could be achieved without any handling of the sample. Thus it is possible to detect rather small differences between the two types of irradiation. Recovery experiments at 400 deg K after 75 deg K irradiation and pinning rates during irradiation at 400 deg K and 75 deg K were made. (GE)

1973-01-01

21

Submicron-scale patterns on ferromagnetic-antiferromagnetic Fe/NiO layers by focused ion beam (FIB) milling  

Energy Technology Data Exchange (ETDEWEB)

With the aim of studying the magnetic properties of reduced-dimensionality magnetic systems we have patterned 250 nm- and 500 nm-size square elements on Fe/NiO layers by 30 keV Ga{sup +} focused ion beam (FIB) milling, varying beam current and pixel dwell time. By high resolution scanning electron microscope (SEM) imaging and atomic force microscopy (AFM) analysis we found that island size decreases from the nominal value by increasing the beam current and features sharpness improves on increasing the dwell time. The top surface of the isolated features has a pronounced edge bending which may be as high as 9 nm with respect to the flat inner area of the island and decreases as dwell time grows. By varying the ion fluence we found that such a shape is related to a surface swelling effect occurring at low ion fluence in the irradiated areas. The swelling-related damage at the edges is expected to influence the magnetic ...

2005-04-01

22

Submicron-scale patterns on ferromagnetic-antiferromagnetic Fe/NiO layers by focused ion beam (FIB) milling  

International Nuclear Information System (INIS)

With the aim of studying the magnetic properties of reduced-dimensionality magnetic systems we have patterned 250 nm- and 500 nm-size square elements on Fe/NiO layers by 30 keV Ga"+ focused ion beam (FIB) milling, varying beam current and pixel dwell time. By high resolution scanning electron microscope (SEM) imaging and atomic force microscopy (AFM) analysis we found that island size decreases from the nominal value by increasing the beam current and features sharpness improves on increasing the dwell time. The top surface of the isolated features has a pronounced edge bending which may be as high as 9 nm with respect to the flat inner area of the island and decreases as dwell time grows. By varying the ion fluence we found that such a shape is related to a surface swelling effect occurring at low ion fluence in the irradiated areas. The swelling-related damage at the edges is expected to influence the magnetic properties ...

2005-04-01

23

Effective atomic numbers and electron densities of some biologically important compounds containing H, C, N and O in the energy range 145-1330 keV  

International Nuclear Information System (INIS)

A semi-empirical relation which can be used to determine the total attenuation cross sections of samples containing H, C, N and O in the energy range 145-1332 keV has been derived based on the total attenuation cross sections of several sugars, amino acids and fatty acids. The cross sections have been measured by performing transmission experiments in a narrow beam good geometry set-up by employing a high-resolution hyperpure germanium detector at seven energies of biological importance such as 145.4 keV, 279.2 keV, 514 keV, 661.6 keV, 1115.5 keV, 1173.2 keV and 1332.1 keV. The semi-empirical relation can reproduce the experimental values within 1-2%. The total attenuation cross sections of five elements carbon, aluminium, titanium, copper and zirconium measured in the same experimental set-up at the energies mentioned ...

2006-09-28

24

Inelastic scattering of electrons by close-lying levels of isomeric nuclei  

Energy Technology Data Exchange (ETDEWEB)

The process of inelastic scattering of hot plasma electrons with energies upto 3 keV by a pair of close-lying nuclear levels (..delta../ital E/less than or equal to2keV), one of whichis isomeric, is discussed. The transition cross sections in the nuclei/sup 242/Am, /sup 171/Lu, and /sup 73/Se are calculated. Estimates of the numberof isomeric nuclei de-excited as a result of electron-stimulated processes in aplasma with parameters characteristic of present-day experiments in controlledthermonuclear fusion are given.

1988-11-01

25

Penetration effect in the M1 component of "1"7"7Ta #gamma#-transition with energy of 70.45 keV  

International Nuclear Information System (INIS)

The magnetic #beta#-spectrometer of the #pi# #sq root#2 type with 0.07% pulse resolution is used to measure the intensities of interval conversion electrons on L- and M-subshells of 70.45 keV "1"7"7 Ta gamma-transition. The results are analyzed and the values of mixing parameter #sigma#(E2/M1) and penetration parameter #lambda# are obtained.

26

Improved FNAL linac beam choppers  

Energy Technology Data Exchange (ETDEWEB)

A discussion is presented of the 750-KeV chopper experience with both proton and negative ion beams and the ability of these systems to tailor the Linac beam to the diverse requirements of its users; normal accelerator injection, neutron therapy beam, and electron cooling experiments. This flexibility plus a cleaner beam pulse, improved thyratron operation, and mechanical modularity are the results of recent improvements. Additional benefits have been increased reliability and ease of service to the 750-KeV chopper. 3 refs.

1981-06-01

27

Multiple glomus tumours: successful treatment with electron beam irradiation  

Energy Technology Data Exchange (ETDEWEB)

A case is reported of a 23-year old male with multiple glomus tumours that showed marked involution after he had electron beam therapy. (author).

1990-11-01

28

Ion beam pulsing for time of flight (TOF) experiments  

Energy Technology Data Exchange (ETDEWEB)

The essential mechanical and electronic parts of a beam pulsing system are described, which reaches an energy resolution of ..delta..E/E=0.1%-0.4% in the energy range from 100 eV and 10 keV.

1985-01-01

29

The characteristics of ion-beam-induced spontaneous etching of GaAs by low-energy focused ion beam irradiation  

International Nuclear Information System (INIS)

We have investigated the characteristics of ion-beam-induced spontaneous etching (IBISE) of GaAs in Cl_2 ambient by using a Ga-focused ion beam (FIB) with an energy ranging from 3 to 15 keV. The etched depth of the irradiated region was more than 20 times greater than that of unirradiated region. When the sputtered depth by FIB irradiation amounted to around 8 A at each ion energy, the etched depth in Cl_2 ambient for 1 hour became saturated. The saturated etched depths were 450, 550, 750 and 800 A at the ion energy of 3, 5, 10 and 15 keV, respectively. The residual damage of the etched surface was also investigated by photoluminescence (PL) measurement. The maximal PL intensity was obtained at around the threshold dose of IBISE and increased with decreasing ion energy. The full recovery of PL intensity was observed at the ion energy of 3 keV after annealing at 400degC. (author).

30

Double-electron-capture cross section for I/sup +/ in a magnesium-vapor target  

Energy Technology Data Exchange (ETDEWEB)

Measurements of the double-electron-capture process in which a positive ion of iodine becomes a negative ion in a single collision with a magnesium atom are reported between 20 and 90 keV. The cross section is comparable to that for the rare gases and not as large as might be expected from a two-valence-electron atom. This process is probably insignificant in the production of negative ion beams using a magnesium-vapor target.

1987-06-15

31

Radiation effect on optical, electrophysical and surface properties of GaAlAs heterostructures  

Energy Technology Data Exchange (ETDEWEB)

A study was made on the effect of 3.5 MeV electron irradiation on the properties of light-emissive structure based on GaAlAs. It is shown that a considerable decrease in the emitted light intensity as a result of electron irradiation not accompanied by changes in recombination- and electric properties of the mentioned structures. It is established by the electron-microscopy and Auger-spectroscopy meazurements that electron irradiation causes the occurrence of regions of free aluminium clusters on the external surface of the structure n-layer. The number and the sizes of the regions depend on the electron doze. It was assumed that the mentioned regions can play a role of attenuation filter for the light emitted by the structure.

1984-07-01

32

Experimental study of beam optics and energy recovery for high-energy electron cooling device  

International Nuclear Information System (INIS)

The feasibility of a high-energy electron cooling device has been studied through tests on a prototype of the electron device. The apparatus consists of a pulsed ((20-60) keV, 2#mu#s) electron gun, a drift region 1 m long and of a depressed collector for recovering the electron energy. Tests on beam optics and energy recovery have been performed, a high-energy recovery efficiency has been attained. Experimental results are discussed in this paper.

33

Characteristics of wave-particle interaction in a hydrogen plasma  

International Nuclear Information System (INIS)

We study the characteristics of cyclotron wave-particle interaction in a typical hydrogen plasma. The numerical calculations of minimum resonant energy Emin, resonant wave frequency ?, and pitch angle diffusion coefficient D?? for interactions between R-mode/L-mode and electrons/protons are presented. It is found that Emin decreases with ? for R-mode/electron, L-mode/proton and L-mode/electron interactions, but increase with ? for R-mode/proton interaction. It is shown that both R-mode and L-mode waves can efficiently scatter energetic (10 keV-100 keV) electrons and protons and cause precipitation loss at L=4, indicating that perhaps wave-particle interaction is a serious candidate for the ring current decay. (authors)

2008-09-01

34

Energetic electrons in impulsive and extended solar flares as deduced from flux correlations between hard X-rays and microwaves  

Energy Technology Data Exchange (ETDEWEB)

The peak flux relationship between hard X-rays and microwaves from solar flares is studied using about 400 events simultaneously recorded with the hard X-ray burst spectrometer on the SMM satellite and the Nobeyama 17 GHz radiometer. The data indicate that the hard X-ray and microwave peak fluxes correlate best for X-ray energies of less than about 80 keV for impulsive flares and greater than about 360 keV for extended flares. By postulating that electrons responsible for microwave emission at 17 GHz are those emitting hard X-rays at these photon energies, it is concluded that: (1) in impulsive flares, microwaves at about 20 GHz are emitted mainly by electrons of less than about 200 keV from a layer through which the electrons stream down into the thick-target hard X-ray source; and (2) in extended flares, microwaves are emitted mainly by MeV ...

1988-01-01

35

Observed energy dependence of Fano factor in silicon at hard X-ray energies  

Energy Technology Data Exchange (ETDEWEB)

An experimental evaluation of the Fano factor F in silicon at hard X-ray energies (5.9-136.5 keV) has been performed by means of a low-noise, high charge collection efficiency silicon drift detector with on-chip electronics. A dependence of F from the detector temperature as well as from the energy of the X-ray photons has been found. Assuming a pair creation energy equal to 3.64 eV, at +20 deg. C the F factor was observed to vary from 0.124{+-}0.006 at 5.9 keV up to 0.159{+-}0.002 at 122 keV. At -35 deg. C, the change of F with respect to the photon energy was less remarkable but nevertheless statistically significant, from 0.123{+-}0.002 at 5.9 keV up to 0.134{+-}0.001 at 122 keV. To our knowledge, the present results represent the first experimental evidence of an energy dependence of the Fano factor in silicon at hard X-ray energies.

1999-03-01

36

0--30 keV low-energy focused ion beam system  

Energy Technology Data Exchange (ETDEWEB)

Low-energy focused ion beam (FIB) is a useful tool for shallow doping, gas-assisted etching, and other uses to minimize substrate damage in semiconductor device fabrication. The possibility to form a finely FIB of low energy under 1 keV was suggested in the investigations on the retarding mode in electron optical systems. The abilities of the simplest type of retarding mode FIB column are examined here. The optical properties are calculated for the corresponding model and some images are observed with Ga/sup +/ ion beams <0.3 ..mu..m in diameter for beam energies, 10, 5, and 1 keV, using a retarding mode one-lens FIB system. 1-keV and 100-eV Ga/sup +/ FIB was implanted to Ga/As substrate, and the defects are analyzed by deep-level transient spectroscopy. The defect concentration for 100 eV was < (1)/(5) that for 1000 keV.

1988-05-01

37

0--30 keV low-energy focused ion beam system  

International Nuclear Information System (INIS)

Low-energy focused ion beam (FIB) is a useful tool for shallow doping, gas-assisted etching, and other uses to minimize substrate damage in semiconductor device fabrication. The possibility to form a finely FIB of low energy under 1 keV was suggested in the investigations on the retarding mode in electron optical systems. The abilities of the simplest type of retarding mode FIB column are examined here. The optical properties are calculated for the corresponding model and some images are observed with Ga"+ ion beams <0.3 #mu#m in diameter for beam energies, 10, 5, and 1 keV, using a retarding mode one-lens FIB system. 1-keV and 100-eV Ga"+ FIB was implanted to Ga/As substrate, and the defects are analyzed by deep-level transient spectroscopy. The defect concentration for 100 eV was < (1)/(5) that for 1000 keV.

38

Irradiation effects on passive films formed on a 304 Type stainless steel  

Energy Technology Data Exchange (ETDEWEB)

The effects of {alpha} particle irradiation on a passive film formed on a 304 type stainless steel are studied in situ. The experimental arrangement minimizes the radiolysis effects due to the electrolyte. Under irradiation, a modification of the electronic structure of the oxide layers is revealed by photo-electrochemistry and impedance measurements. The influence of irradiation on the corrosion resistance of the passive film is investigated. Comparing the rest potential and the breakdown potential respectively under and without irradiation, a drop in the passivity range under irradiation is shown. this is interpreted as a decrease in the corrosion resistance. (author).

1990-01-01

39

Irradiation effects on passive films formed on a 304 Type stainless steel  

International Nuclear Information System (INIS)

The effects of #alpha# particle irradiation on a passive film formed on a 304 type stainless steel are studied in situ. The experimental arrangement minimizes the radiolysis effects due to the electrolyte. Under irradiation, a modification of the electronic structure of the oxide layers is revealed by photo-electrochemistry and impedance measurements. The influence of irradiation on the corrosion resistance of the passive film is investigated. Comparing the rest potential and the breakdown potential respectively under and without irradiation, a drop in the passivity range under irradiation is shown. this is interpreted as a decrease in the corrosion resistance. (author).

1990-01-01

40

Transmission electron microscopy of simulated DWPF high level nuclear waste glasses following gamma irradiation  

International Nuclear Information System (INIS)

Thermal analysis testing revealed slight weight changes, which were a function of gamma irradiation, in a highly reduced Defense Waste Processing Facility (DWPF) simulated waste glass. Transmission electron microscopy (TEM) was performed on this glass to determine if the weight change corresponded to microstructural variations. TEM analyses showed that no microstructural changes were attributable to gamma irradiation. Exposure of the samples to the electron beam in the TEM did cause changes in the glass microstructures in some cases. These changes were likely due to localized heating of the glass due to interactions with the transmitted electrons.

1994-04-25

41

The characterization of electron beam and its importance  

International Nuclear Information System (INIS)

The necessity of the electron beam machine characterization via dose measurement is discussed. It includes a measurement of comprehensive dose distribution (at known X and Z axis) for verification of the machine performance. The acquired data were then used to develop the irradiation parameters such as energy, current, distance, conveyor speed, exposure rate and depth inside product to be irradiated. These parameters will be used as a guide for the routine irradiations. (Author)

2003-07-22

42

The effects of energy non-monochromaticity of "1"1B ion beams on "1"1B diffusion  

International Nuclear Information System (INIS)

We have shown that energy contamination introduced by ion beam deceleration technology that is used to increase the beam currents available for low energy boron implants, can affect fabricated junctions adversely. A 4 keV "1"1B beam is extracted and retarded by a potential of -3.5 keV for 0.5 keV "1"1B implantation, or by a potential of -3.8 keV for 0.2 keV "1"1B implantation. Intentional beam contamination was introduced by turning off the retarding potential to allow the 4 keV "1"1B ions to irradiate Si wafers directly. The percentage of contamination, at levels of 0.1%, 0.2% and 0.3% was introduced. Rapid thermal annealing of all the implanted samples was performed under N_2 ambient at 1050 deg. C for 1 s. The dopant tail profiles themselves are not significant if the contamination levels are low. However, the much higher damage level ...

2005-08-01

43

RXTE observations of Cas A  

International Nuclear Information System (INIS)

Rossi X-ray Timing Explorer (RXTE) observations of the bright supernova remnant Cas A have revealed a hard power law component above 10 keV in addition to two thermal components inferred from ASCA measurements of the many line centroids from low-Z elements. The power law can be shown to be consistent with synchrotron emission from radio to hard x-rays by electrons of up to 4 x 10"1"3 eV. Measurement of the 1157 keV line by CGRO from "4"4Sc in the chain of decay of "4"4Ti predicts that the two "4"4Ti lines at 68 and 78 keV should appear at the CGRO intensity. RXTE has placed upper limits on such lines that are marginally consistent with the CGRO measurement. Implications of these results on sites for cosmic ray acceleration and nucleosynthesis are discussed.

1999-01-01

44

Influencing factors on ESR dose assessment in irradiated chicken legs  

Energy Technology Data Exchange (ETDEWEB)

Electron spin resonance (ESR) dosimetry of irradiated chicken legs is based on the additive dose or the calibration curve methods. In both cases the practical assumption is made that the behaviour of the chicken bone does not depend on factors such as temperature during irradiation, storage conditions and dose rate. So the aim of the present work was to investigate to what extent the above mentioned factors could influence the post-irradiation dose assessment using the ESR technique. (author).

1996-12-31

45

A mechanism for the degradation of superconducting transition temperatures on high energy neutron irradiation in A-15 compounds  

International Nuclear Information System (INIS)

Electron microscopic observations of neutron irradiated Nb_3Sn revealed the presence of highly disordered regions of size approximately 35 A in a much less disordered matrix. This observation is shown to provide a means of explaining quantitatively many superconducting properties of irradiated A-15 compounds. In particular Tsub(c) of the irradiated materials could be easily predicted using the mathematical formulations developed for the proximity effect. (Auth.).

46

Irradiation hardening of reduced activation martensitic steels  

International Nuclear Information System (INIS)

Irradiation response on the tensile properties of 9Cr-2W steels has been investigated following FFTF/MOTA irradiations at temperatures between 646 and 873 K up to doses between 10 and 59 dpa. The largest irradiation hardening accompanied by the largest decrease in the elongation is observed for the specimens irradiated at 646 K at doses between 10 and 15 dpa. The irradiation hardening appears to saturate at a dose of around 10 dpa at the irradiation temperature. No hardening but softening was observed in the specimens irradiated at above 703 K to doses of 40 and 59 dpa. Microstructural observation by transmission electron microscope (TEM) revealed that the dislocation loops with the a left angle 100 right angle type Burgers vector and small precipitates which were identified to be M_6C type carbides existed after the ...

47

Monte Carlo code comparisons for the calculation of absorbed dose per unit fluence in slab phantoms for electron energies from 50 keV to 10 MeV  

International Nuclear Information System (INIS)

The MCNPE-BO and MCNP4 Monte Carlo electron-photon codes were used to calculate the dose equivalent per unit fluence at various depths in tissue-equivalent slab phantoms for broad parallel beams of monoenergetic electrons with energies from 50 keV to 10 MeV. The study was carried out in the framework of the activities of a ICRP/ICRU Joint Task Group with the support of EURADOS WG4 (Numerical Dosimetry). Some preliminary results and comparisons as well as a general discussion on the performances of the codes are presented, demonstrating quite a satisfactory agreement among the results obtained using the two codes and those of other authors. (author).

48

Defect creation by electronic processes in MgO bombarded with GeV heavy ions  

Energy Technology Data Exchange (ETDEWEB)

To study the defect creation induced by electronic processes in refractory oxides, MgO single crystals were irradiated with high energy tin, uranium and lead ions. Optical absorption measurements showed that F-type centers (oxygen vacancies with trapped electrons) were created during irradiation. The total number of centers per unit area of bombarded sample increases linearly with irradiating fluence. The main part of the point defects was found to arise from electronic processes. The concentration of F-type centers induced by ionization increases with the electronic energy losses. Assuming a saturation of point defect concentration at high fluences, F-type center creation cross sections could be estimated. The influence of irradiation temperature and of the velocity of the bombarding ions are discussed.

1996-12-31

49

Electron detachment cross-sections and secondary-electron emission factors for heavy-negative-ion beams  

Energy Technology Data Exchange (ETDEWEB)

The properties of negative-ion beams are very important for designing negative-ion apparatus and applications of negative-ion beams, especially, electron detachment cross-sections at the interaction between negative-ion beams and gas particles in the transport system, and secondary-electron emission factors when negative ions are incident on solid surfaces. These properties of negative-ion beams were investigated experimentally as a function of the ion energy under 50 keV. The single electron detachment cross-sections are almost constant in the other of 10[sup -15] cm[sup 2] in this energy range, but double electron detachment cross-sections increase in proportion to the ion velocity and much smaller than the single one. As for the secondary-electron emission factor, the emission factors for negative-ion beam are found to be larger by 1 than those for ...

1994-01-01

50

Electron detachment cross-sections and secondary-electron emission factors for heavy-negative-ion beams  

International Nuclear Information System (INIS)

The properties of negative-ion beams are very important for designing negative-ion apparatus and applications of negative-ion beams, especially, electron detachment cross-sections at the interaction between negative-ion beams and gas particles in the transport system, and secondary-electron emission factors when negative ions are incident on solid surfaces. These properties of negative-ion beams were investigated experimentally as a function of the ion energy under 50 keV. The single electron detachment cross-sections are almost constant in the other of 10"-"1"5 cm"2 in this energy range, but double electron detachment cross-sections increase in proportion to the ion velocity and much smaller than the single one. As for the secondary-electron emission factor, the emission factors for negative-ion beam are found to be larger by 1 than those for positive-ion ...

1994-01-01

51

Intraoperative and external beam irradiation for locally advanced colorectal cancer.  

UK PubMed Central (United Kingdom)

In view of poor local control rates obtained with standard treatment, intraoperative radiation (IORT) using electrons was combined with external beam irradiation and surgical resection, with or without...Full Text Available

1988-01-01

52

Transient enhanced diffusion of oxygen in Fe mediated by large electronic excitation  

International Nuclear Information System (INIS)

Contrary to the electronic excitation induced phenomena of desorption and sputtering, we observed incorporation of oxygen in a thin Fe film during its irradiation with swift heavy ions. It is observed that the adsorbed oxygen diffuses in to the Fe film. The incorporation of oxygen and its diffusion in the bulk of the film is a manifestation of extremely large electronic energy deposition by the incident ions. It is shown that the experimentally observed high diffusivity of oxygen in Fe during irradiation is due to the existence of transient melt phase of Fe.

2003-10-15

53

Formation of oriented nanocrystals in an amorphous alloy by focused-ion-beam irradiation  

International Nuclear Information System (INIS)

Structural changes of a Ni-P amorphous alloy under focused-ion-beam (FIB) irradiation have been examined using transmission electron microscopy. On the irradiated plane, the formation of crystallographically orientated nanosized crystals (NCs), with the particle size of approximately 10 nm, was observed. A series of electron diffraction analyses have revealed that NCs have a face-centered-cubic (fcc) structure and the following orientation relationships between the NCs and the FIB direction were found. These are, irradiated plane//(111)_f_c_c and FIB direction//_f_c_c.

2002-12-09

54

Procedure for radiation dose control in irradiated tissues during electron-beam therapy  

International Nuclear Information System (INIS)

The invention refers a procedure of radiation dose control in irradiated tissues during electron-beam therapy. It aims at meeting the planned radiation dose for diseased tissues and taking care of the healthy ones. Therefore, the dose distribution required is determined before irradiation in consideration of such factors as energy-dependence of detector sensitivity, self-absorption within the tissue, and relative biological effectiveness. Furthermore, the expected intensity distribution of secondary quantum radiation excited in the irradiated tissue is calculated. A radiation detector for local resolution is used for registration. During irradiation the calculated intensity distribution is compared with the measured one. The invention is applicable in radiation therapy with monoenergetic electron beams.

1984-11-08

55

Evaluation of induced radioactivity in 10 MeV-electron irradiated spices, (1)  

International Nuclear Information System (INIS)

Black pepper, white pepper, red pepper, ginger and turmeric were irradiated with 10 MeV electrons from a linear accelerator to a dose of 100 kGy and radioactivity was measured in order to estimate induced radioactivity in the irradiated foods. Induced radioactivity could not be detected significantly by #gamma#-ray spectrometry in the irradiated samples except for spiked samples which contain some photonuclear target nuclides in the list of photonuclear reactions which could produce radioactivity below 10 MeV. From the amount of observed radioactivities of short-lived photonuclear products in the spiked samples and calculation of H_5_0 according to ICRP Publication 30, it was concluded that the induced radioactivity and its biological effects in the 10 MeV electron-irradiated natural samples were negligible in comparison with natural radioactivity from "4"0K contained in the ...

56

Some physical considerations in whole skin electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

The short range of low-energy electrons has made them suitable for the treatment of skin lesions, especially when extensive areas must be irradiated with special considerations to save the normal underlying tissue. This report covers some salient features of total body electron irradiation: the construction of the large fields required, x-ray contamination levels, and multiple-field techniques. While the investigation is essentially experimental, we also indicate the results of calculations. We conclude most generally that treatment planning with whole skin irradiations can be as precise as with smaller fields.

1982-09-01

57

Structural and magnetic studies on the enhancement of the giant magnetoimpedance by ion irradiation  

British Library Electronic Table of Contents (United Kingdom)

The mechanism of abrupt increase of the giant magneto impedance (GMI) ratio in the ion irradiated Co-based amorphous ribbon has been investigated. The grazing incident X-ray diffraction and transmission electron microscope were used to characterize the samples before and after ion irradiation. The GMI-ratio considerably increased in the ion irradiated samples and the GMI response showed strong dependence on the driving frequencies. The Barkhausen noise (BN) signals are increased for the Ar ion irradiated sample with dose of 1x10^1^7 ion/cm^2. The results are interpreted in terms of GMI variation associated with domain wall dynamics.

2011-01-01

58

Hardness and defect structures in EC316LN austenitic alloy irradiated under a simulated spallation neutron source environment using triple ion-beams  

Energy Technology Data Exchange (ETDEWEB)

For an assessment of the future US spallation neutron source (SNS) target performance, radiation induced hardening and microstructural evolution were investigated as a function of ion dose for EC316LN stainless steel. Irradiation was carried out using 3.5 MeV Fe{sup +}, 360 keV He{sup +}, and 180 keV H{sup +} simultaneous ion-beams at 200 deg. C to simulate the damage, He and H production in the SNS target vessel wall. At low dose (< 1 dpa), the predominant defects were black dots whose number density saturated rapidly within a few dpa. This was followed by the evolution of interstitial loops whose number density saturated below 15 dpa. Although He-bubbles were not visible, severely scalloped loops suggested that the implanted He/H atoms existed in the form of small clusters. Comparison with reported neutron irradiation data showed that hardening and ductility loss occurred mostly in the black ...

2000-04-01

59

Hardness and defect structures in EC316LN austenitic alloy irradiated under a simulated spallation neutron source environment using triple ion-beams  

International Nuclear Information System (INIS)

For an assessment of the future US spallation neutron source (SNS) target performance, radiation induced hardening and microstructural evolution were investigated as a function of ion dose for EC316LN stainless steel. Irradiation was carried out using 3.5 MeV Fe"+, 360 keV He"+, and 180 keV H"+ simultaneous ion-beams at 200 deg. C to simulate the damage, He and H production in the SNS target vessel wall. At low dose (< 1 dpa), the predominant defects were black dots whose number density saturated rapidly within a few dpa. This was followed by the evolution of interstitial loops whose number density saturated below 15 dpa. Although He-bubbles were not visible, severely scalloped loops suggested that the implanted He/H atoms existed in the form of small clusters. Comparison with reported neutron irradiation data showed that hardening and ductility loss occurred mostly in the black dot regime (< 1 ...

2000-04-01

60

Surface segregation and radiation hardening of 16Cr12MoWSiVNbB steel after irradiation with Ni++ and He+ ions  

British Library Electronic Table of Contents (United Kingdom)

Irradiation of EP-823 (16Cr12MoWsiVNbB) ferritic-martensitic steel with 7-MeV Ni++ ions and with 30- and 70-keV He+ ions at a temperature of 500?C was followed by an increase in the microhardness, which was due to both radiation point defects and changes in the phase composition and the dislocation structure of the steel. It was found that the dependence of the largest relative increase in the microhardness on the concentration of radiation-induced point defects in the near-surface region of the steel under irradiation with different ions correlated with an analogous dependence of the surface segregation of silicon and chromium.

2011-01-01

61

Particle and X-ray damage in pn-CCDs  

Energy Technology Data Exchange (ETDEWEB)

The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.

2000-01-11

62

Effects on focused ion beam irradiation on MOS transistors  

Energy Technology Data Exchange (ETDEWEB)

The effects of irradiation from a focused ion beam (FIB) system on MOS transistors are reported systematically for the first time. Three MOS transistor technologies, with 0.5, 1, and 3 {mu}m minimum feature sizes and with gate oxide thicknesses ranging from 11 to 50 nm, were analyzed. Significant shifts in transistor parameters (such as threshold voltage, transconductance, and mobility) were observed following irradiation with a 30 keV Ga{sup +} focused ion beam with ion doses varying by over 5 orders of magnitude. The apparent damage mechanism (which involved the creation of interface traps, oxide trapped charge, or both) and extent of damage were different for each of the three technologies investigated.

1997-04-01

63

Effects of ion irradiation on the diffusion of pre-implanted B atoms in crystalline silicon  

International Nuclear Information System (INIS)

N-type crystalline Si (100) implanted with 5 keV B ions was subsequently irradiated with MeV Si, O and F ions. The B atom profiles were measured by means of secondary ion mass spectrometer after the treatment of rapid thermal annealing. The results show that the transient enhanced diffusion of B atoms is effectively limited by the post-implantation of high energy ions at high dose. At the same irradiation conditions, it is found that the existence of a SiO_2 layer in the near surface of Si is even more effective in suppressing the transient enhanced diffusion of the doped B atoms. The results are qualitatively discussed in combination with the analyses of RBS/c measurements and calculation of the DICADA code

2001-12-01

64

Comparative evolution of various CCD image sensors hardening techniques with ionizing radiation  

International Nuclear Information System (INIS)

This paper reviews various techniques to harden Charged Coupled Device (CCD) sensors and the results after irradiation of three Thomson n buried channel CCDs having a different degree of hardening. It describes the major irradiation effects on CCD performances and it makes a comparison of the results between the different hardening levels. It shows good results on dark voltage after ionizing radiation for TH 7863M device hardened both by design and by operating conditions (MPP mode) with respect to the standard device TH 7863A. The irradiations were performed with "6"0Co or X-ray (10 keV) sources on devices in operating mode. (author). 3 refs., 8 figs.

66

Study of implantation damage in germanium formed using Ga"+ FIB  

International Nuclear Information System (INIS)

Full text: It is known that the ion implantation of germanium single crystals at room temperature results in drastic alteration of the germanium surface and the formation of cellular relief. Voids were found into the near-surface damage layer. The intersection of these voids with the germanium surface, as result of sputter etching, forms cellular relief. However, exact mechanism responsible for formation of the voids is not known. A 10 and 30 keV Ga"+ irradiation of Ge #left brace#100#right brace# crystal at room temperature was carried out using a focused ion beam (FIB) system with a dose in the range 0.5x10"1"2 to 1.5x10"1"4 ion/cm"2. The topology of the modified germanium surface and the structure of the radiation damage was studied using imaging facilities of the FIB systems and transmission electron microscopy. The strong cellular structure of Ge was observed after an ion dose of 3x10"1"3 ion/cm"2. High-resolution TEM ...

67

Properties of cubic boron nitride films with buffer layer control for stress relaxation using ion-beam-assisted deposition  

Energy Technology Data Exchange (ETDEWEB)

Significant ion irradiation during film growth is required for the formation of cubic boron nitride (cBN) films. Meanwhile, a huge level of intrinsic stress possibly induced by the ion bombardment has been frequently reported to result in cracking and/or lack of adhesion of deposited cBN films. The present work has been performed to investigate the interfacial and/or the buffer layer structures with better matching to the cBN film by relaxation of the film stress using ion-beam-assisted deposition (IBAD). Boron nitride films have been synthesized on Si(100) wafer and tungsten carbide (WC) substrates by depositing boron vapor under simultaneous bombardment with nitrogen ions and nitrogen-argon mixture ions in the energy range of 0.5-10 keV. Cubic BN films with enhanced tribological properties have been explored by inserting a BN layer with various B/N compositions as a controlled buffer at the interface. Significant relaxation of the film stress ...

1999-09-01

68

Impurity and clustering effects on defect evolution in ion-implanted Si  

Energy Technology Data Exchange (ETDEWEB)

A detailed investigation of the damage formation and evolution in ion-implanted crystalline Si is presented. Deep-level transient spectroscopy has been used to monitor room temperature migration of point defect complexes and evolution from simple point-like defect complexes to defect clusters and even extended defects. Si samples were implanted with Si or He ions with energies of 145 keV-3MeV, to fluences in the range 5x10[sup 8]-5x10[sup 13]cm[sup -2]. The effects of thermal annealing, in the range 100-680 C and 10 min-15h, were also explored. A systematic comparison of defect complexes formation and evolution in ion-implanted or electron-irradiated Si samples with a different impurity content were used to assess the role of impurities (C and O), extra implanted ion and defect clustering on the nature and thermal stability of residual damage. In particular, an interstitial excess directly resulting from the extra implanted ion is shown to ...

1998-10-01

69

Determination of ratios of emission probabilities of Auger electrons and K-L-shell radiative vacancy transfer probabilities for 17 elements from Mn to Mo at 59.5keV  

Energy Technology Data Exchange (ETDEWEB)

The measurements of the K X-ray intensity ratio I(K{sub {beta}})/I(K{sub {alpha}}) for the 17 elements Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Br, Rb, Sr, Y, Zr, Nb and Mo have been done following ionization by 59.5keV {gamma}-rays from a {sup 241}Am point source. Ratios of emission probabilities of Auger electrons and the vacancy transfer coefficients have been extracted in terms of the intensity ratios. It is found that the present results agree well with earlier fitted values and the semi-empirical values.

2006-01-15

70

Triple ion-beam studies of radiation damage in 9Cr2WVTa ferritic/martensitic steel  

Energy Technology Data Exchange (ETDEWEB)

To simulate radiation damage under a future Spallation Neutron Source (SNS) environment, irradiation experiments were conducted on a candidate 9Cr-2WVTa ferritic/martensitic steel using the Triple Ion Facility (TIF) at ORNL. Irradiation was conducted in single, dual, and triple ion beam modes using 3.5 MeV Fe{sup ++}, 360 keV He{sup +}, and 180 keV H{sup +} at 80, 200, and 350{degrees}C. These irradiations produced various defects comprising black dots, dislocation loops, line dislocations, and gas bubbles, which led to hardening. The largest increase in hardness, over 63 %, was observed after 50 dpa for triple beam irradiation conditions, revealing that both He and H are augmenting the hardening. Hardness increased less than 30 % after 30 dpa at 200{degrees}C by triple beams, compatible with neutron irradiation data from previous work which ...

1997-11-01

71

DECAY OF Ta$sup 177$ AND Lu$sup 177$ TO LEVELS IN Hf$sup 17$$sup 7$  

Science.gov (United States)

The decays of Ta/sup 177/ and Lu/sup 177/ to levels in vestigated with beta spectrometers, NaI(Tl) gamma spectrometers, and fast coincidence and angular correlation techniques. Energy levels in Hf/sup 177/ were characterized according to their energy (kev), the Nilsson asymptotic quantum numbers (Nn/sub 2/ LAMBDA ), the total angular momentum and its component along the symmetry axis (I,K), and the parity ( pi ) as follows: 0STA5I4 7/2, 7/2-!; 112.97STA514 9/2, 7/ 2-!; 249.7STA5I4 11/2, 7/1-!; 32l.34STA624 9/2, 9/2+1; 447.9STA624 11/2, 585.8STA642 7/2, 3/2+1; 509.0STA5I2 5/2, 5/1-1; 605.5STA512 7/2, 5/2-!; 746.04STA633 7/2, 7/2+1; 848.2STA 633 9/2, 7/2+1; and 1058.38STA503 7/2, 7/2-!. The levels at 447.9, 488.8, and 585.8 kev are tentative. The spins and parities were uniquely determined by angular correlation and internal conversion data for the levels at 746.0 and 848.2 kev, asof the levels at 0, ...

1961-10-15

72

The radiation hardening and microstructural defect evolution in ion irradiated Fe-Cr alloys with irradiation temperature  

International Nuclear Information System (INIS)

Generally, neutron, ion and electron Irradiations cause a substantial amount of hardening and significantly alter the deformation behavior of metals and alloys at relatively low irradiation temperatures. A radiation hardening is caused by the formation of microstructural defects such as dislocation loops, voids and precipitates under irradiation. Therefore, it is important to have a better knowledge of the irradiation induced microstructural defects under irradiation condition. As a part of the National mid- and long-term atomic energy R and D program, we are dealing with the radiation hardening behavior in Fe-Cr binary alloy. Fe-Cr binary alloy is a base alloy of Ferritic/Martensitic steel(F/M steel) planning to use for the Gen IV nuclear system. In this work, we investigated the radiation hardening and microstructural defect evolution in ion ...

2009-05-01

73

Study on the variations of molecular structures of some biomolecules induced by free electron laser using FTIR spectroscopy  

International Nuclear Information System (INIS)

In this study, free electron laser (FEL) with selective wavelength was used to induce structure changes of biomolecules, which were characterized by FTIR spectroscopy. For understanding of the interactions between FEL and biomolecules as well as biological tissues, the biomolecules investigated are ATP, ADP, AMP, t-RNA, D-ribose and the complex of SmCl_3-D-ribose. Their FTIR spectra before and after irradiation of FEL show molecular structure variations of the samples after irradiation of FEL, especially the rearrangement of their hydrogen bond networks. Along with the various irradiation wavelengths, irradiation time and molecular structures, the changes after irradiation are different for these molecules. In the FTIR spectra after irradiation, the phenomenon that the bands split into several peaks indicates the existence of several ...

2007-05-01

74

Comparison of beam-induced deposition using ion microprobe  

International Nuclear Information System (INIS)

The localized Pt deposition on Si by 30 keV Ga"+ focused ion beam (FIB), 10 keV electron beam (EB) or dual beams (FIB and EB) using precursor gas has been compared by analysis using a 300 keV Be"2"+ microprobe with a beam spot size of 80 nm. The distribution of deposited Pt, Ga from the ion beam itself, and C from the precursor gas was obtained at and nearby the deposited areas by micro-RBS spectra and RBS mapping. All of the beam processed areas showed a uniform Pt distribution at the deposited areas. The amount of Pt atoms increased with the increase in ion or electron dose due to the decomposition of precursor gas. The thickness of Pt layer by EB is considerably less than that by FIB due to the reduced deposition rate. Ga atoms from the center of processed areas partly redeposited at and nearby the FIB processed areas within #approx#3 #mu#m. The Ga incorporation by dual beam ...

1999-01-02

75

Irradiation effect on properties of passive film formed on an AISI 304 type stainless steel  

Energy Technology Data Exchange (ETDEWEB)

The study by impedance and photoelectrochemical measurements of passive films formed on an AISI 304 type stainless steel shows that important parameters of the electronic structure of these films are modified under ..cap alpha.. irradiation, namely: width of the space charge region, donors concentration and diffusion length for minority carriers. The consequences of ..cap alpha.. irradiation on localized corrosion processes are discussed.

1989-01-01

76

Irradiation effect on properties of passive film formed on an AISI 304 type stainless steel  

International Nuclear Information System (INIS)

The study by impedance and photoelectrochemical measurements of passive films formed on an AISI 304 type stainless steel shows that important parameters of the electronic structure of these films are modified under #alpha# irradiation, namely: width of the space charge region, donors concentration and diffusion length for minority carriers. The consequences of #alpha# irradiation on localized corrosion processes are discussed.

1989-01-01

77

Effects of gamma irradiation on physiological effectiveness of Korean medicinal herbs  

Energy Technology Data Exchange (ETDEWEB)

Effects of gamma irradiation on the physiological effectiveness of Korean medicinal herbs were investigated. The physiological effectiveness including antioxidant and anticomplement function, nitrite scavenging and electron donating ability of Korean medicinal herbs by gamma irradiation at 10 kGy did not differ from that of the nonirradiated control.

1999-03-01

78

Decree of the Ministry of Health about conditions of irradiation of food, permissible additional substances or other food components, which can be subjected to ionizing radiation action, their specification, maximum irradiation doses as well as about requirements for marking and introducing into turnover  

International Nuclear Information System (INIS)

The decree refers to conditions of irradiation of food and its components for radappertization and radurization using gamma radiation from cobalt 60 or cesium 137, X radiation or electron beam up to maximum total medium absorbed dose 10 kGy.

2003-03-04

79

Effect of helium and hydrogen production on hardness of F82H steel irradiated by dual/triple ion beams  

International Nuclear Information System (INIS)

Effect of helium and hydrogen production on radiation-hardening of F82H irradiated by dual or triple beam condition were investigated. The specimens used were four types of ferritic martensitic steels of F82H-std (Fe-8Cr-2W-0.2V-0.04Ta-0.1C) steels tempered at 750degC for 60 minutes, 20% cold worked F82H steel, F82H tempered for 10 minutes and non-tempered F82H steels. The irradiation was performed at 450degC to 50 dpa under simultaneous dual beams of 10.5 MeV Fe"3"+ and 1.05 MeV He"+ or triple beams of those and 380 keV H"+ ions. The ratios of He (appm)/dpa and H(appm)/dpa were 15 nad 15 (or 150) for dual and triple ion beams. The hardness of the irradiated specimens measured at room temperature using a micro indentation after the irradiations. The hardness in these F82H steels irradiated at 450degC to 18 dpa under triple beam irradiation ...

2003-03-01

80

The influence of electron-beam irradiation on some mechanical properties of commercial multilayer flexible packaging materials  

International Nuclear Information System (INIS)

The influence of electron-beam irradiation on mechanical properties of commercial multilayer flexible packaging materials based on coextruded and laminated polypropylene (PP), low-density polyethylene (LDPE), ethylene vinyl alcohol copolymer (EVOH) and poly(ethylene terephthalate) (PET), irradiated with doses up to 120 kGy, was studied. The tensile strength and elongation at break of the irradiated PET/PP film increase, while the penetration and sealing resistance decreased. In addition, the irradiated PET/LDPE/EVOH/LDPE film presented increase in the tensile strength on some radiation doses and decrease of the penetration and sealing resistance, except for sealing resistance at radiation dose of 15 kGy that resulted in a slight increase of ca 4%.

2008-09-21

81

Influence of MeV electron irradiation on the properties of by ion implantation hydrogenated polysilicon TFTs  

Energy Technology Data Exchange (ETDEWEB)

The influence of MeV electrons irradiation on the gate oxide layers of hydrogenated polysilicon thin film transistors (TFTs) was investigated by measuring gate leakage currents and threshold voltages. The experimental data revealed a decrease of oxide trap density and increase of positive oxide charge. Improvement in the interface roughness and in the oxide quality near the bottom interface was observed.

2006-02-15

82

Influence of MeV electron irradiation on the properties of by ion implantation hydrogenated polysilicon TFTs  

International Nuclear Information System (INIS)

The influence of MeV electrons irradiation on the gate oxide layers of hydrogenated polysilicon thin film transistors (TFTs) was investigated by measuring gate leakage currents and threshold voltages. The experimental data revealed a decrease of oxide trap density and increase of positive oxide charge. Improvement in the interface roughness and in the oxide quality near the bottom interface was observed.

2006-02-01

83

Hardening process relating to the irradiation of active electronic components and large hardened components  

International Nuclear Information System (INIS)

A patent is claimed for the invention of a hardening (ionizing radiation resistance) process for MOS type components and CMOS or bipolar type components. The ionizing radiation effect on those systems is the electron-hole pair production, which induces interference phenomena. The MOS main structure is successively composed of a silicon substrate layer, a layer of an irradiation resistant material and a layer of partially monocrystalline silicon.

1988-12-09

84

Intensity of auger-emission of silicon from binary compounds in the ion auger spectroscopy  

International Nuclear Information System (INIS)

Auger-electron emission from different silicides has been studied for 4 and 10 keV Ar ion excitation. The intensity of the SiLMM Auger line changes significantly with channing concentration and atomic number of the metal-parthner. The experimental results can be explained in terms of a simple model based on the probability of Si-Si collision symmetric cascade in these binary compounds.

85

High energy heavy ion irradiation in semiconductors  

Energy Technology Data Exchange (ETDEWEB)

Pd/n-Si and Pd/n-GaAs devices have been irradiated from high energy ({approx}100 MeV) heavy ions of Au{sup 7+} (gold) and Si{sup 7+} (silicon) to study the irradiation effects in these junction devices on semiconductor substrates. The devices have been characterized from I-V and C-V studies for electronic flow characterization. It has been found that the devices become high resistive on the irradiation and the substrates change the conductivity type from n- to p- on the irradiation of fluence of {approx}10{sup 12}-10{sup 13} ions/cm{sup 2}. The change in conductivity type has been understood as a result of creation of deep acceptors on the irradiation.

1999-07-02

86

Low temperature proton irradiation of amorphous Pd/sub 80/Si/sub 20/ prepared by ion implantation  

Energy Technology Data Exchange (ETDEWEB)

The damage induced by low-temperature proton irradiation in amorphous Pd/sub 80/Si/sub 20/ prepared by ion implantation is studied via electrical resistivity measurements. Our experimental results concerning the initial damage rate and the resistivity saturation are compared to the results obtained for electron and high energy /sup 16/O irradiation of amorphous Pd/sub 80/Si/sub 20/ quenched from the melt. The resistivity curve is analyzed in terms of irradiation-induced point defects.

1984-05-01

87

Deep-level defects and numerical simulation of radiation damage in GaAs solar cells  

Energy Technology Data Exchange (ETDEWEB)

A review of the deep-level defects observed in both electron- and proton-irradiated GaAs solar cells is presented. Studies of the effects of periodic and continuous thermal annealing on the radiation-induced electron and hole traps and the recombination parameters in GaAs solar cells were made for a wide range of electron and proton energies, fluence, annealing temperature and annealing time. A refined model for numerical simulations of the displacement damage was developed for computing the defect density and the cell parameters in the electron- and proton-irradiated GaAs solar cells. Excellent agreement was obtained between the calculated values and the experimental data for the proton-irradiated GaAs solar cells. (orig.).

1991-09-01

88

Solid-state ozone synthesis by energetic ions  

International Nuclear Information System (INIS)

We have synthesized ozone by irradiating thin solid films of oxygen and oxygen-water mixtures with 100 keV protons, motivated by recent reports of condensed O_3 on icy satellites in the outer Solar system. We measured the depth of the Hartley absorption band in the ultraviolet by reflectance spectroscopy and used it to quantify the column density of ozone. We analyzed the results using a three-component (O, O_2 and O_3) model that successfully explains the fluence dependence of ozone production.

1999-08-02

89

CMOS/SOI hardening at 100 MRAD (SiO_2)  

International Nuclear Information System (INIS)

Hardened CMOS/SOI 29101 microprocessor, elementary cells and transistor shave been irradiated at levels between 10 Mrad(SiO_2) and 1 Grad(SiO_2) ("6"0Co and 10 keV x-rays). SIMOX buried oxide behavior in the range of 100 Mrad(SiO_2) and a channel-stopped MOS/SOI structure avoiding lateral leakage current are presented. These two items indicate the feasibility of a CMOS/SOI technology operating in the hundred Mrad(SiO_2) range.

1990-07-16

90

The enhanced genomic instability was induced by alpha particle and low-energy ion irradiation in somatic cells of Arabidopsis thaliana  

International Nuclear Information System (INIS)

Although low-energy ion radiation has been proven to have a wide range of biological effects and led to fruitful achievements as a new mutagenic source for genetic modification, there still exist some disputes about its mutagenic mechanisms because of its short-penetrating property. In present research, Arabidopsis thaliana transgenic for GUS recombination substrate was used to evaluate the genomic instability induced by irradiations of alpha particle (3.3MeV) and Low-energy-Argon ion (30 KeV). A pronounced effects of alpha particle irradiation to Arabidopsis thaliana seedlings and Argon ion irradiation to seeds on the somatic homologous recombination frequency (sHRF) were reported. The sHRFs increased 1.88-fold and 2.42-fold, respectively, which indicated that the short-penetrating radiation could effectively induce the plant genomic instability in either dry seeds or seedlings with active metabolism. ...

2008-08-12

91

Effect of helium and hydrogen production on irradiation hardening of F82H steel irradiated by ion beams  

International Nuclear Information System (INIS)

Effects of helium and hydrogen production on irradiation hardening of martensitic steel F82H (Fe-8Cr-2W-0.2V-0.04Ta-0.1C) were examined by dual or triple beam experiments. The effects of tempering and cold working were also examined. The irradiations were performed at about 500degC to 50 dpa under simultaneous dual beams of 10.5 MeV Fe"3"+ and 1.05 MeV He"+ or triple beams of those and 380 keV H"+ ions. The value of appm-He/dpa for the dual ion beams was about 15, and the values of appm-He/dpa and appm-H/dpa for the triple ion beams were 15 and 15 (or 150), respectively. The hardness of the irradiated specimens measured at room temperature using a micro indentation after the irradiations. Irradiation softening and hardening was observed in F82H-std, F82H+20%CW and a non-tempered F82H steels irradiated at about 500degC to 18 and 50 dpa, ...

2007-06-01

92

Simulation study on retention and reflection from tungsten carbide under high fluence of helium ions  

Energy Technology Data Exchange (ETDEWEB)

We have studied, by a Monte Carlo simulation code ACAT-DIFFUSE, the fluence-dependence of the amount of retained helium atoms in tungsten carbide at room temperature under helium ion bombardment. The retention behavior may be understood qualitatively in terms of irradiation-dependent diffusion coefficient assumed and range. The emission processes from tungsten carbide under helium ion irradiation derived were compared with each other. We have discussed the retention curves for incident energy of 5 keV at incident angles of 0deg and 80deg and of 500 eV at 0deg. The energy spectra of helium atoms reflected from tungsten carbide for incident energy of 500 eV at 0deg and 80deg were compared with those from graphite and tungsten. (author)

2000-08-01

93

A study of methyl formate in astrochemical environments  

CERN Document Server

Several complex organic molecules are routinely detected in high abundances towards hot cores and hot corinos. For many of them, their paths of formation in space are uncertain, as gas phase reactions alone seem to be insufficient. In this paper, we investigate a possible solid-phase route of formation for methyl formate (HCOOCH3). We use a chemical model updated with recent results from an experiment where simulated grain surfaces were irradiated with 200 keV protons at 16 K, to simulate the effects of cosmic ray irradiation on grain surfaces. We find that this model may be sufficient to reproduce the observed methyl formate in dark clouds, but not that found in hot cores and corinos.

2011-01-01

94

Effects of ionizing radiation on properties of monolayer and multilayer flexible food packaging materials  

International Nuclear Information System (INIS)

Volatile compounds produced in flexible food packaging materials (LDPE, EVAc, PET/PE/EVOH/PE) during electron beam irradiation were isolated by purge and trap technique and identified by combined gas chromatography-mass spectrometry (GC/MS), after thermal desorption and concentration. For comparison purposes non-irradiated films were also studied. Film samples were irradiated at low (5 kGy, corresponding to cold pasteurization), intermediate (20 kGy, corresponding to cold sterilization) and high (100 kGy) doses. It was observed that a number of volatile compounds are produced after irradiation in all cases. Furthermore the amounts of all volatile compounds increase with increasing irradiation dose. Both primary (methyl-derivatives etc.) as well as secondary i.e. oxidation products (ketones, aldehydes, alcohols, carboxylic acids etc.) are produced upon ...

1999-05-01

95

Microprobe RBS analysis of localized processed areas by FIB etching and deposition  

International Nuclear Information System (INIS)

Localized beam-processed areas using chemical reactions induced by a 30 keV Ga"+ focused ion beam (FIB) with and without I_2 (etching) and (CH_3)_3CH_3C_5H_5Pt gases (Pt deposition) have been analyzed using a 300 keV Be"2"+ microprobe with a beam spot size of 50-80 nm. The analyzed results have been compared with energy dispersive X-ray (EDX) analysis using an electron beam. The EDX analysis only indicated incorporated impurities at high fluence such as Ga, Pt and C, while microprobe RBS analysis could detect residual iodine with low concentration which couldn't be detected by EDS analysis because of the lower sensitivity of the EDX analysis for heavy atoms.

2001-07-01

96

Light emission from hydrogen-copper interaction at grazing incidence  

Energy Technology Data Exchange (ETDEWEB)

The optical emission of excited H reflected from clean Cu(110) after impingement of H/sup +/ and H/sub 2//sup +/ in the energy range of 250 eV to 20 keV per nucleon at 70/sup 0/ angle of incidence to the surface normal was measured. For incident 10 keV H/sub 2//sup +/, the highest excited hydrogen state detected was the n=10 level. The Hsub(..cap alpha..) yield was found to be fluence and energy dependent. This effect is attributed either to fast sputtered hydrogen, surface roughness or to an increase with hydrogen concentration in electron states of p-like symmetry near the Fermi level of copper. The Hsub(..cap alpha..) yield per reflected nucleon shows approximately an exponential dependence on both projectile energy per nucleon and scattered particle reciprocal velocity perpendicular to the surface.

1984-03-01

97

Light emission from hydrogen-copper interaction at grazing incidence  

International Nuclear Information System (INIS)

The optical emission of excited H reflected from clean Cu(110) after impingement of H"+ and H_2"+ in the energy range of 250 eV to 20 keV per nucleon at 70"0 angle of incidence to the surface normal was measured. For incident 10 keV H_2"+, the highest excited hydrogen state detected was the n=10 level. The Hsub(#alpha#) yield was found to be fluence and energy dependent. This effect is attributed either to fast sputtered hydrogen, surface roughness or to an increase with hydrogen concentration in electron states of p-like symmetry near the Fermi level of copper. The Hsub(#alpha#) yield per reflected nucleon shows approximately an exponential dependence on both projectile energy per nucleon and scattered particle reciprocal velocity perpendicular to the surface. (orig.).

1983-07-01

98

Self-organized amorphous material in silicon (0 0 1) by focused ion beam (FIB) system  

Energy Technology Data Exchange (ETDEWEB)

A method using a focused ion beam (FIB) to prepare a silicon amorphous material is presented. The method involves the redeposition of sputtered material generated during the interaction of the Ga{sup +} ion beam with a silicon substrate material. The shape and dimensions of this amorphous material are self-organized and reproducible. The stability of this amorphous material under electron irradiation was investigated in the transmission electron microscopy (TEM). Electron irradiation can induce recrystallization of the amorphous material, resulting in the lateral and vertical growth, starting at an amorphous-crystalline interface, of polysilicon containing defects.

2005-12-15

99

Self-organized amorphous material in silicon (0 0 1) by focused ion beam (FIB) system  

International Nuclear Information System (INIS)

A method using a focused ion beam (FIB) to prepare a silicon amorphous material is presented. The method involves the redeposition of sputtered material generated during the interaction of the Ga"+ ion beam with a silicon substrate material. The shape and dimensions of this amorphous material are self-organized and reproducible. The stability of this amorphous material under electron irradiation was investigated in the transmission electron microscopy (TEM). Electron irradiation can induce recrystallization of the amorphous material, resulting in the lateral and vertical growth, starting at an amorphous-crystalline interface, of polysilicon containing defects.

2005-12-15

100

Dephasing of two electron states in a double quantum-dot system irradiated by a microwave field with a nearby Quantum Point Contact  

CERN Document Server

In this work we study the dephasing mechanism of a double quantum-dot system, which includes two electrons and a nearby quantum point contact (QPC) as a measurement device. We obtain that the QPC-induced decoherence is on time scales of microseconds. We also find that the electrons will be delocalized after continuous measurement, irrespectively of the initial conditions, and the frequent repeated measurements will localize the system, which is consistent with the quantum Zeno effect. Further, we consider the situation that the double quantum-dot system is irradiated by a microwave field.

2008-01-01

101

Test of electron beam technology on Savannah River Laboratory low-activity aqueous waste for destruction of benzene, benzene derivatives, and bacteria  

Energy Technology Data Exchange (ETDEWEB)

High energy radiation was studied as a means for destroying hazardous organic chemical wastes. Tests were conducted at bench scale with a {sup 60}Co source, and at full scale (387 l/min) with a 1.5 MV electron beam source. Bench scale tests for both benzene and phenol included 32 permutations of water quality factors. For some water qualities, as much as 99.99% of benzene or 90% of phenol were removed by 775 krads of {sup 60}Co irradiation. Full scale testing for destruction of benzene in a simulated waste-water mix showed loss of 97% of benzene following an 800 krad dose and 88% following a 500 krad dose. At these loss rates, approximately 5 Mrad of electron beam irradiation is required to reduce concentrations from 100 g/l to drinking water quality (5 {mu}g/l). Since many waste streams are also inhabited by bacterial populations which may affect filtering operations, the effect of ...

1993-08-01

102

Oil palm empty fruit bunch (OPEFB) fiber reinforced PVC/ENR blend-electron beam irradiation  

Energy Technology Data Exchange (ETDEWEB)

The effect of irradiation on the tensile properties of oil palm empty fruit bunch (OPEFB) fiber reinforced poly(vinyl chloride)/epoxidized natural rubber (PVC/ENR) blends were studied. The composites were prepared by mixing the fiber and the PVC/ENR blend using HAAKE Rheomixer at 150 deg. C. The composites were then irradiated by using a 3.0 MeV electron beam machine at doses ranging from 0 to 100 kGy in air and room temperature. The tensile strength, Young's modulus, elongation at break and gel fraction of the composites were measured. Comparative studies were also made by using poly(methyl acrylate) grafted OPEFB fiber in the similar blend system. An increase in tensile strength, Young's modulus and gel fraction, with a concurrent reduction in the elongation at break (Eb) of the PVC/ENR/OPEFB composites were observed upon electron beam irradiation. Studies ...

2007-12-15

103

Electron and ion beam effects in amorphous SiO_2 and Si_3N_4 films for electronic devices  

International Nuclear Information System (INIS)

The effect of electron and ion beam irradiation on the Sisub(LVV) Auger spectra of SiO_2, Si_3N_4 and Si-oxynitride films was measured by the relative intensity of the 92 eV signal, characteristic for the formation of 'free' silicon during irradiation. While in Si-oxynitride the beam effects were almost negligible, some damage was found in Si_3N_4, but SiO_2 appeared to be extremely sensitive for electron and ion beam irradiation. By low energy electron loss spectroscopy of ion bombarded SiO_2 and Si_3N_4 films new electron states due to broken Si-O and Si-N bonds could be determined within the band gap of the insulators. The measured energy losses were interpreted by means of electron energy level schemes of the amorphous films. (author).

1982-01-01

104

Electron and ion beam effects in amorphous SiO/sub 2/ and Si/sub 3/N/sub 4/ films for electronic devices  

Energy Technology Data Exchange (ETDEWEB)

The effect of electron and ion beam irradiation on the Sisub(LVV) Auger spectra of SiO/sub 2/, Si/sub 3/N/sub 4/ and Si-oxynitride films was measured by the relative intensity of the 92 eV signal, characteristic for the formation of 'free' silicon during irradiation. While in Si-oxynitride the beam effects were almost negligible, some damage was found in Si/sub 3/N/sub 4/, but SiO/sub 2/ appeared to be extremely sensitive for electron and ion beam irradiation. By low energy electron loss spectroscopy of ion bombarded SiO/sub 2/ and Si/sub 3/N/sub 4/ films new electron states due to broken Si-O and Si-N bonds could be determined within the band gap of the insulators. The measured energy losses were interpreted by means of electron energy level schemes of the amorphous films.

1982-10-01

105

Spinal axis irradiation with electrons: Measurements of attenuation by the spinal processes  

Energy Technology Data Exchange (ETDEWEB)

Electrons may be used beneficially for spinal axis irradiation in medulloblastoma children to avoid some of the long-term sequelae induced by megavoltage photons. However, the attenuation by the intervening bone ought to be considered. Three-dimensional computer treatment planning with inhomogeneity correction for electron beams is not yet generally available, and alternate methods are needed to evaluate the attenuation by the complex bony structure of the spine. Here, we present our experimental data showing the alteration in the electron isodoses due to the intervening spinous processes. Film dosimetric measurements were made in the vertebral columns obtained from autopsies of a goat, a dog, and a child. Our results show that electron beam therapy for the spinal axis is a viable option.

1986-07-01

106

Portal localization images using computed radiography for high-energy electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy electron beam therapy. (author)

2002-09-01

107

One-electron reduction of chloroperoxidase by radiolytically generated electrons  

Energy Technology Data Exchange (ETDEWEB)

Upon irradiation of aqueous ethylene glycol/water solutions of native chloroperoxidase (CPO) with {sup 60}Co-gamma rays at 77K one observes the one-electron reduction of the enzyme active site by radiolytically generated thermolyzed electrons. In the present study the first absorption spectrum of a low-spin ferrous form of CPO is reported which has peaks at 438, 532 and 563 nm, similar to those observed previously for cytochrome P-450. All previously described ferrous forms of CPO are high spin. In order to observe the final results of the CPO reaction with electrons, the spectral changes of native enzyme after room temperature-gamma-irradiation have also been investigated. Evidence of changes is also presented probably connected with disruption of the tertiary structure of enzyme, correlated with decrease of enzyme activity.

1990-05-16

108

One-electron reduction of chloroperoxidase by radiolytically generated electrons  

International Nuclear Information System (INIS)

Upon irradiation of aqueous ethylene glycol/water solutions of native chloroperoxidase (CPO) with "6"0Co-gamma rays at 77K one observes the one-electron reduction of the enzyme active site by radiolytically generated thermolyzed electrons. In the present study the first absorption spectrum of a low-spin ferrous form of CPO is reported which has peaks at 438, 532 and 563 nm, similar to those observed previously for cytochrome P-450. All previously described ferrous forms of CPO are high spin. In order to observe the final results of the CPO reaction with electrons, the spectral changes of native enzyme after room temperature-gamma-irradiation have also been investigated. Evidence of changes is also presented probably connected with disruption of the tertiary structure of enzyme, correlated with decrease of enzyme activity.

1990-05-01

109

X-RAY MICROANALYSIS OF A RADIOACTIVE PARTICLE WITH THE AID OF THE ELECTRON MICROSCOPE  

Science.gov (United States)

A radioactive particle was analyzed to discover the composition of the inactive material of the particle. The method uses the x-ray line spectrum of the K series caused by electron irradiation of the particle in the electron microscope. Iron and aluminum or silicon (the last two could not be distinguished) were found as inactive components in the particle. (D.L.C.)

1962-07-28

110

Use of electron beam irradiation to improve the microbiological safety of Hippophae rhamnoides  

Energy Technology Data Exchange (ETDEWEB)

Sea buckthorn (Hippophae rhamnoides) is increasingly used in food supplements due to its dietary and medicinal compounds with a beneficial role in human diet and health. As many other medicinal plants, sea buckthorn can be contaminated with microorganisms which exerts an important impact on the overall quality of the products. Irradiation is an effective method for food preservation because it is able to destroy pathogenic microorganisms keeping the organoleptic and nutritional characteristics of the foods. The objective of the present study was to investigate the application of electron beam irradiation in order to improve the microbiological safety of sea buckthorn. The experimental results indicated that the electron beam treatment might be a good method to remove undesirable microorganisms from sea buckthorn without significant changes in its active principles.

2007-09-21

111

Experimental studies on reconstruction of peripheral arteries by high voltage cathode ray irradiated allografts  

International Nuclear Information System (INIS)

The use of cathode ray irradiated arterial allografts on the reconstruction of small peripheral arteries is described. The fate of irradiated arterial allografts implanted subcutaneously in rats was compared histologically with that of allografts which were fresh, frozen or stored in 70% alcohol. Follow-up studies were made of 10 dogs in which irradiated arterial allografts had been implanted in the femoral artery to be evaluated; long term patency by arteriography, gross and histologic changes of the implanted allografts, and the luminal surface of the implanted allografts by scanning electron microscopic studies. For the purpose of antigenic studies, extracts of canine arteries which had been irradiated, frozen or stored in 70% alcohol, were prepared and tested by the following immunological methods: precipitation, Ouchterlony gel diffusion, and passive cutaneous anaphylaxis. From ...

1976-01-01

112

Effects of gamma and electron beam irradiation on the properties of calendered cord fabrics  

Energy Technology Data Exchange (ETDEWEB)

The effects of gamma and e-beam irradiation on mechanical and structural properties of nylon 66 (Ny 66), nylon 6 (Ny 6) and poly(ethylene terephthalate) (PET) fabrics used in tyres were investigated. The untreated (greige), treated cords and calendered fabrics were irradiated at different doses. It is found that the effects of high energy irradiation on greige, treated cords and calendered fabrics are similar. No protective effect of compounds used in calendering was observed against radiation-induced oxidative degradation. The deterioration effect of gamma irradiation on mechanical properties is much higher than that of e-beam irradiation for all types of samples. Limiting viscosity numbers of both gamma and e-beam irradiated nylon 6 and nylon 66 cords were found to decrease with increasing dose. It is concluded that PET calendered fabric has higher resistance ...

2010-03-15

113

Irradiation of human insulin in aqueous solution, first step towards radiosterilization  

British Library Electronic Table of Contents (United Kingdom)

The degradation of irradiated human insulin in aqueous solutions was investigated in order to protect the protein against ionizing radiation. The influence of the drug concentration, excipients and irradiation temperature were studied.Aqueous solutions at pH 2 were irradiated by gamma rays or by accelerated electrons. Two different high-performance liquid chromatography (HPLC) methods were used: reverse-phase high-performance liquid chromatography (RP-HPLC)/UV and size exclusion liquid chromatography (SEC/UV) to investigate both the fragmentation and the formation of higher molecular weight proteins.In solution without excipients irradiated at ambient temperature at 10kGy, the loss of human insulin is almost complete. Addition of radio-protecting excipients (free radicals scavengers) and c...

2007-01-01

114

Irradiation induced dislocation loop and its influence on the hardening behavior of Fe-Cr alloys by an Fe ion irradiation  

International Nuclear Information System (INIS)

Nano indentation analysis and transmission electron microscopy observation were performed to investigate a microstructural evolution and its influence on the hardening behavior in Fe-Cr alloys after an irradiation with 8 MeV Fe4+ ions at room temperature. Nano indentation analysis shows that an irradiation induced hardening is generated more considerably in the Fe-15Cr alloy than in the Fe-5Cr alloy by the ion irradiation. TEM observation reveals a significant population of the a0 dislocation loops in the Fe-15Cr alloy and an agglomeration of the 1/2a0 dislocation loops in the Fe-5Cr alloy. The results indicate that the a0 dislocation loops will act as stronger obstacles to a dislocation motion than 1/2a0 dislocation loops.

2008-11-01

115

Valence-electron configuration of Ti and Ni in TixNi1-x alloys from Kbeta-to-Kalpha X-ray intensity ratio studies.  

Science.gov (United States)

Kbeta-to-Kalpha X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of Ti(x)Ni(1-x) (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi (109)Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured Kbeta-to-Kalpha X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one ...

2010-01-28

116

Valence-electron configuration of Ti and Ni in TixNi1-x alloys from K?-to-K? X-ray intensity ratio studies  

International Nuclear Information System (INIS)

K?-to-K? X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of TixNi1-x (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi 109Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured K?-to-K? X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other ...

2010-06-01

117

A study of radiation embrittlement using simulation irradiation  

International Nuclear Information System (INIS)

Simulation irradiation experiments were carried out to investigate the formation processes and contribution to hardening of radiation-induced features in low alloy steels. Medium Cu (0.12 and 0.16%) and low Cu (0.03%) A533B steels were irradiated with 3 MeV Ni ions and 5 MeV electrons, and in KUR at 290degC. Irradiated steels were examined by three-dimensional atom probe, positron annihilation, high-resolution transmission electron microscopy and hardness measurements. Electron irradiation caused almost the same hardening as KUR irradiation in medium Cu steels under almost the same dose rate and dose conditions, whereas the formation of larger, denser and more Cu enriched clusters and smaller accumulation of single vacancies were confirmed for KUR irradiation. This indicated that cascade damage ...

2008-10-13

118

Pulse power considerations for the generation of 45 #mu#s, 200 keV electron beams for CO_2 lasers  

International Nuclear Information System (INIS)

A two module electron beam source operating over a wide range of output parameters has been designed and fabricated to be used in conjunction with a pair of electron beam sustained CO_2 lasers. Each module comprised a grid-controlled thermionic electron beam gun including a compact grid pulser for control of the electron beam, a 250 kV thyratron switched modulator for acceleration of the electron beam, a 1 kHz filament heater and a complex computerized control system. The system was designed to reliably produce 45 #mu#s wide electron pulses of 150-200 keV energy, operate at repetition rates of 1-10 pps and current densities of 5-20 mA/cm"2. Additional parameters are listed. The high voltage cathode assembly employs 132 thoriated tungsten filaments distributed over the area of the 250 cm x 10 cm output window. The cathode assembly including ...

1989-01-19

119

VLF wave stimulation by pulsed electron beams injected from the space shuttle  

International Nuclear Information System (INIS)

Among the investigations conducted on the space shuttle flight STS 3 March 1982 was an experiment in which a 1-keV, 100-mA electron gun was pulsed at 3.25 and 4.87 kHz. The resultant waves were measured with a broadband plasma wave receiver. At the time of flight the experimental setup was unique in that the electron beam was square wave modulated and that the shuttle offered relatively long times for in situ measurements of the ionospheric plasma response to the VLF pulsing sequences. In addition to electromagnetic response at the pulsing frequencies the waves exhibited various spectral harmonics as well as the unexpected occurrence of satellite lines around those harmonics. Both phenomena occurred with a variety of different characteristics for different pulsing sequences.

120

Absolute differential cross sections for electron capture and loss by kilo-electron-volt hydrogen atoms  

International Nuclear Information System (INIS)

This paper reports measurements of absolute differential cross sections for electron capture and loss for fast hydrogen atoms incident on H_2, N_2, O_2, Ar, and He. Cross sections have been determined in the 2.0- to 5.0-keV energy range over the laboratory angular range 0.02 degree--2 degree, with an angular resolution of 0.02 degree. The high angular resolution allows us to observe structure at small angles in some of the cross sections. Comparison of the present results with those of other authors generally shows very good agreement.

121

Influence of high energy electron irradiation on the characteristics of polysilicon thin film transistors  

Energy Technology Data Exchange (ETDEWEB)

The influence of high energy electron (23 MeV) irradiation on the electrical characteristics of p-channel polysilicon thin film transistors (PSTFTs) was studied. The channel 220 nm thick LPCVD (low pressure chemical vapor deposition) deposited polysilicon layer was phosphorus doped by ion implantation. A 45 nm thick, thermally grown, SiO{sub 2} layer served as gate dielectric. A self-alignment technology for boron doping of the source and drain regions was used. 200 nm thick polysilicon film was deposited as a gate electrode. The obtained p-channel PSTFTs were irradiated with different high energy electron doses. Leakage currents through the gate oxide and transfer characteristics of the transistors were measured. A software model describing the field enhancement and the non-uniform current distribution at textured polysilicon/oxide interface was developed. In order to assess the ...

2006-08-15

122

Influence of high energy electron irradiation on the characteristics of polysilicon thin film transistors  

International Nuclear Information System (INIS)

The influence of high energy electron (23 MeV) irradiation on the electrical characteristics of p-channel polysilicon thin film transistors (PSTFTs) was studied. The channel 220 nm thick LPCVD (low pressure chemical vapor deposition) deposited polysilicon layer was phosphorus doped by ion implantation. A 45 nm thick, thermally grown, SiO_2 layer served as gate dielectric. A self-alignment technology for boron doping of the source and drain regions was used. 200 nm thick polysilicon film was deposited as a gate electrode. The obtained p-channel PSTFTs were irradiated with different high energy electron doses. Leakage currents through the gate oxide and transfer characteristics of the transistors were measured. A software model describing the field enhancement and the non-uniform current distribution at textured polysilicon/oxide interface was developed. In order to assess the ...

2006-08-01

123

EPR investigation of some traditional oriental irradiated spices  

International Nuclear Information System (INIS)

The 9.50 GHz electron paramagnetic resonance (EPR) spectra of unirradiated and "6"0Co #gamma#-ray irradiated cardamom (Elettaria cardamomum L. Maton, Zingiberaceae), ginger ((Zingiber officinale Rosc., Zingiberaceae), and saffron (Crocus sativus L., Iridaceae) have been investigated at room temperature. All unirradiated spices presented a weak resonance line with g-factors around free-electron ones. After #gamma#-ray irradiation at an absorbed dose of up to 11.3 kGy, the presence of EPR spectra whose amplitude increase monotonously with the absorbed dose has been noticed with all spices. A 100 "oC isothermal annealing of 11.3 kGy irradiated samples has shown a differential reduction of amplitude of various components that compose initial spectra, but even after 3.6 h of thermal treatment, the remaining amplitude represents no less then 30% of the initial ones. The same peculiarities ...

2007-06-01

124

Measurement of gamma-ray detection efficiency in irradiated materials examination facility  

Energy Technology Data Exchange (ETDEWEB)

The detection efficiency of gamma scanning system in irradiated materials examination facility has been measured. Gamma-ray sources used in this experiment are Cs-Co standard sources a PWR spent fuel rod in which {sup 134}Cs and {sup 154}Eu peaks are clearly identified in the energy region of 500 to 1,600 keV. The distance between source and detector is about 1.6 m. A slit type collimator with 3 mm-width window and 30 mm-thick lead block are installed between source and detector. The detector is a HPGe detector. This equipment is mainly used in gamma scanning of irradiated nuclear fuel. The measured detection efficiency seems to be 1.89 x 10{sup -6} % for 1 MeV gamma-ray. With these results the activities of unknown sources could be measured. This results are expected to be used in the measurement of the absolute distribution of gamma emitting nuclides in nuclear fuel.

2001-05-01

125

Optical properties of proton-irradiated polymers  

Energy Technology Data Exchange (ETDEWEB)

Recently, organic semiconducting materials have gained a broad interest due to their potential for organic electronic devices such as organic light emitting diode (OLED), organic photovoltaic devices and organic field-effect transistors (OFETs). Optical properties of organic semiconducting materials are important for practical application. For example, the power conversion efficiency of organic photovoltaic devices is mainly affected by absorption properties of organic materials. Proton irradiation is one of the efficient methods to change the optical properties of organic materials. In this paper, we investigate the changes of optical properties of various polymers using the proton irradiation.

2009-05-15

126

Spectral energy effects in ESR bone dosimetry: photons and electrons  

International Nuclear Information System (INIS)

The spectral energy-dependence of the radiation-induced ESR signal has been studied in ovine cortical bone. Crushed bone samples were irradiated using photon beams with effective energies in the range from 0.06 to 6 MeV, and electron beams with mean energies in the range from 2 to 10 MeV. The photon and electron data were normalized to a dose to bone of 50 Gy and the results are reported as response relative to the ESR signal for photon irradiation at 1.25 MeV ("6"0Co). The photon irradiation results show that the ESR response is greatest at low energies with a relative value of 1.2 at 0.06 MeV. The relative response decreases, as the energy increases, to approximately 0.85 in the region of 2 to 3 MeV. These variations in the relative ESR responses are significantly less than the ESR energy-dependent responses reported in the literature for human tooth enamel and synthetic ...

127

Rotational Subtotal Skin Electron Beam Therapy for Management of Carcinoma en Cuirasse  

UK PubMed Central (United Kingdom)

Recurrent or primary carcinoma of the breast en cuirasse, which may involve the skin of the entire thorax and abdomen, cannot be controlled by means of surgery or conventional local irradiation. The...Full Text Available

1987-07-01

128

An evaluation of the pendulum technique of electron beam therapy  

International Nuclear Information System (INIS)

Electron beam therapy of lesions such as cutaneous metastatic carcinoma and reticulum cell sarcoma is performed via multiple portals for a wide irradiation field. However, the dose distribution in border areas is generally uneven, resulting in hot and cold dose areas depending on the intervals of the portals. We performed electron irradiation by the pendulum technique, especially on curved areas, and evaluated the technique in various respects. Pendulum electron beam irradiation is indicated when the length of the cone must be reduced in order to deliver the target volume near the skin surface as well as to avoid the occurrence of hot spots deep in the body. We prepared a 15cm rotating cone by cutting a 30cm fixed irradiation cone. The modification posed no disadvantages in terms of extent and flatness of the beam, or stability during ...

129

Accelerator aspects of #gamma#-#gamma# colliders  

International Nuclear Information System (INIS)

There are several on-going projects of e"+e"- colliders. If they are constructed, we can convert them into photon-photon (#gamma#-#gamma#) colliders by converting electron beams into #gamma# beams, irradiating laser beams just before the interaction point. In this report we discuss the technical issues on the accelerator.

2000-11-21

130

Low-energy measurements of electron capture by multicharged ions from excited hydrogen atoms  

International Nuclear Information System (INIS)

For very low collision energies electron capture from excited hydrogen by multicharged ions is characterized by enormous cross sections, the predicted maximum being comparable to the geometric size of the Rydberg atom. The ion-atom merged-beams technique is being used to study these collisions for the variety of charge states and the wide range of energies (0.1 to 1000 eV/amu) accessible to the apparatus. A neutral D beam containing a Rydberg atom population proportional to 1/n"3 is produced by collisional electron detachment of 8 keV D"- in N_2 gas. An applied electric field results in the range (n=24--11) depending on the strength of the field applied. This beam is then merged with O"3"+ or O"5"+ ion beams at low relative collision velocities where the resultant beam-beam signal of D"+ due to electron loss is dominated by electron capture. From the sharp decrease in the observed ...

131

Kinetics of low-temperature radiation hardening of metallic materials under irradiation  

British Library Electronic Table of Contents (United Kingdom)

A formula is obtained which describes the kinetics of low-temperature radiation hardening caused by creation of dislocation loops of interstitial type during irradiation. The radiation hardening of aluminum and vanadium is estimated using this formula and results of experiments on studying processes of nucleation and growth of interstitial dislocation loops in these materials by transparent electron microscopy. It is shown that the proposed formula is valid for description of the kinetics of low-temperature radiation hardening.

2011-01-01

132

Cluster-loop structure influence on molybdenum radiation hardening  

International Nuclear Information System (INIS)

Results on defect structure study and degree of molybdenum radiation hardening irradiated by fission neutrons and medium energy alpha-particles are presented. It is shown that molybdenum irradiation by alpha-particles and neutrons leads to different degree of material hardening for the same damage level. It is established that molybdenum radiation hardening is mainly defined by radiation defect clusters visible in electron microscope whose coefficient of rigidity depends on their size. 5 refs.; 6 figs.; 2 tabs. (author).

1990-05-22

133

Comparison of methods to measure the rate of neutral free radical production by photo-deionization of negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

Two measurement methods to determine the rate of neutral free radical production by the photo-deionization of negative ion beams (PDINIB) are introduced. These methods, namely, photoelectron-current measurement by low-frequency electro-modulation probe (PMMP) and measurement of decrease in the negative-ion beam current (DNIC) were employed to evaluate the production rate in a trial surface-processing apparatus developed in the author's laboratory utilizing a steady-flux refined beam of neutral free radicals (RBNR) produced by the PDINIB procedure. A {sup 63}Cu{sup -} negative ion beam of kinetic energy E{sub i} varied up to 15 keV was irradiated with a 514.5 nm visible light beam from a 25 W CW Ar{sup +} ion laser. The detection limit of the production rate by the PMMP setup was as high as 6 x 10{sup 9} s{sup -1} under the condition that E{sub i}=15 keV, the negative-ion beam current I{sub i}=4 {mu}A and the laser ...

2003-05-01

134

Beam Test of a Prototype Detector Array for the PoGO Astronomical Hard X-Ray/Soft Gamma-Ray Polarimeter  

CERN Document Server

Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument designed to measure polarization from astrophysical objects in the 30-100 keV range, under development by an international collaboration with members from United States, Japan, Sweden and France. To examine PoGO's capability, a beam test of a simplified prototype detector array was conducted at the Argonne National Laboratory Advanced Photon Source. The detector array consisted of seven plastic scintillators, and was irradiated by polarized photon beams at 60, 73, and 83 keV. The data showed a clear polarization signal, with a measured modulation factor of $0.42 \\pm 0.01$. This was successfully reproduced at the 10% level by the computer simulation package Geant4 after modifications to its ...

2005-01-01

135

Focused ion beam (FIB) milling of electrically insulating specimens using simultaneous primary electron and ion beam irradiation  

International Nuclear Information System (INIS)

There is currently great interest in combining focused ion beam (FIB) and scanning electron microscopy technologies for advanced studies of polymeric materials and biological microstructures, as well as for sophisticated nanoscale fabrication and prototyping. Irradiation of electrically insulating materials with a positive ion beam in high vacuum can lead to the accumulation of charge, causing deflection of the ion beam. The resultant image drift has significant consequences upon the accuracy and quality of FIB milling, imaging and chemical vapour deposition. A method is described for suppressing ion beam drift using a defocused, low-energy primary electron beam, leading to the derivation of a mathematical expression to correlate the ion and electron beam energies and currents with other parameters required for electrically stabilizing these challenging materials.

2007-02-07

136

Study of deferred luminescence emitted by some species of chlorella after #gamma# irradiation at 77 K  

International Nuclear Information System (INIS)

The deferred luminescence (isothermal luminescence -ITL- and thermoluminescence - RTL) emitted by Chlorella cells after #gamma# irradiation at 77 K has been investigated. The decay kinetics of ITL as well as the effect of illumination of both ITL and RTL show that trapped electrons take part in the recombination reactions which give rise to both emissions, and that ITL can be attributed to electron tunnelling. Most strains of Chlorella studied present similar RTL glow curves, the only exceptions found being Chlorella vulgaris (green and bleached strains).

137

Free radicals and their transformations in irradiated proteins  

International Nuclear Information System (INIS)

Experimental investigation data are systematized of free radical states and processes in irradiated proteins. The investigation is performed by the radiospectral methods. Results are discussed in detail of the study of free radicals electronic structure of amino acids, peptides and proteins formed by the action of ionizing radiation. The specificity is stressed of the study of monocrystalls of these compounds by the method of electronic paramagnetic resonance. The nature is also studied of primary centres formed under the effect of radiation on biologically important compounds and their subsequent reactions in solid and liquid solutions. Ion-radical states of different functional groups of the protein molecule are studied. Prospects of the study and the role of anion-radicals in biological processes are discusses.

138

Electron Beam and Gamma Radiolysis of Solid-State Metoclopramide  

British Library Electronic Table of Contents (United Kingdom)

Purpose Study the radiolysis of solid-state metoclopramide hydrochloride at various absorbed doses. Elucidate the structure of the degradation products to gain information on the radiolysis mechanisms. Methods Solid-state metoclopramide samples were irradiated at several doses with gamma rays and high-energy electrons to evaluate the influence of the dose rate. High-performance liquid chromatography with a diode array detector was used to measure the chemical potency as a function of the absorbed dose and to quantify the degradation products. The characterization of degradation products was performed by liquid chromatography/atmospheric pressure chemical ionization/tandem mass spectrometry. Results The degradation of solid-state metoclopramide after irradiation was negligible. No qualitati...

2006-01-01

139

Deposition of Cu film on SiO_2 using a partially ionized beam  

International Nuclear Information System (INIS)

Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO_2 substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio I(111)/I(200) reaches its maximum value indicating a strong left-angle 111 right-angle texture, while the impurity concentration and resisitivity are minimum. The correlation between the structural, compositional and ...

1990-01-01

140

Deposition of Cu film on SiO sub 2 using a partially ionized beam  

Energy Technology Data Exchange (ETDEWEB)

Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO{sub 2} substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio {ital I}(111)/{ital I}(200) reaches its maximum value indicating a strong {l angle}111{r angle} texture, while the impurity concentration and resisitivity are minimum. The correlation between the structural, ...

1990-05-01

141

Deposition of Cu film on SiO sub 2 using a partially ionized beam  

Science.gov (United States)

Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO{sub 2} substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio {ital I}(111)/{ital I}(200) reaches its maximum value indicating a strong {l angle}111{r angle} texture, while the impurity concentration and resisitivity are minimum. The correlation between the structural, ...

1990-05-01

142

Corrosion behaviour of molybdenum-implanted stainless steel  

Energy Technology Data Exchange (ETDEWEB)

A low-molybdenum austenitic stainless steel (UNS S30100) has been surface implanted with molybdenum ions, using various doses of 50 keV and 140 keV ions at room temperature. It is found that in aqueous sulphate/chloride solutions similar to the constitution of sea-waters the implantation does not affect the potentiostatically-determined critical pitting potential, but does change the density and morphology of corrosion pits. Pitting initiation after the addition of chloride at a fixed potential indicates little change in the time for measurable current increase, but the rate of increase of the current is much lower for implanted material. Detailed examination using optical microscopy, scanning electron microscopy, transmission electron microscopy and selected area diffraction suggests that the pits produced in implanted material are hemispherical with smooth covers of unattacked alloy. The use of ...

1990-01-01

143

Corrosion behaviour of molybdenum-implanted stainless steel  

International Nuclear Information System (INIS)

A low-molybdenum austenitic stainless steel (UNS S30100) has been surface implanted with molybdenum ions, using various doses of 50 keV and 140 keV ions at room temperature. It is found that in aqueous sulphate/chloride solutions similar to the constitution of sea-waters the implantation does not affect the potentiostatically-determined critical pitting potential, but does change the density and morphology of corrosion pits. Pitting initiation after the addition of chloride at a fixed potential indicates little change in the time for measurable current increase, but the rate of increase of the current is much lower for implanted material. Detailed examination using optical microscopy, scanning electron microscopy, transmission electron microscopy and selected area diffraction suggests that the pits produced in implanted material are hemispherical with smooth covers of unattacked alloy. The use of ...

1989-09-01

144

"1"5"8Tm and "1"5"6Tm decays  

International Nuclear Information System (INIS)

These experiments were performed on the Isocele separator, on-line with the Orsay synchrocyclotron; thulium isotopes were produced by bombarding natural erbium targets with 150nA beam of 157MeV protons. Two Ge(Li) detectors, with resolution of 2.3 and 2.5keV at 1332keV used for #gamma#-ray measurements; conversion electron spectra were measured using a Si(Li) detector. #gamma# spectra, #gamma#-#gamma# coincidence and conversion electron measurements were sufficient to build the flow energy level schemes of the transitional "1"5"8Er and "1"5"6Er nuclei. On both nuclei several quasi rotational bands have been identified. These results are compared with other even erbium isotopes and with the neighboring N=88 and 90 isotones. Comparisons with predictions issued from some classical models are also performed: "1"5"8Er appears as a deformed nucleus very similar to "1"6"0Er and "1"6"2Er; on the other hand ...

1976-01-01

145

Electron beam curable phenol-formaldehyde resin  

International Nuclear Information System (INIS)

The novolac type phenolic resins were synthesized and electron beam curing was carried out to the prepolymer obtained by the reaction of the phenolic resin and glycidyl meth acrylate in the presence of triethylbenzyl ammonium chloride. When the prepolymer and its mixtures with monomers were irradiated using electron beams at a dose rate of 3 Mrad/sec, the curing were completed at a dose 2.5 and 3 Mrad respectively. The effects of oxygen and that of hydroxyl group in the prepolymer on electron beam curing were also examined. (author).

146

Alopecia associated with unexpected leakage from electron cone  

Energy Technology Data Exchange (ETDEWEB)

Excessive irradiation due to unexpected leakage was found on a patient receiving electron beam therapy. The cause of this leakage was analyzed and the amount of leakage was measured for different electron beam energies. The highest leakage occurred with a 6 x 6 cm cone using a 12 MeV electron beam. The leakage dose measured along the side of the cone could be as great as 40%. Until the cones are modified or redesigned, it is advised that all patient setups be carefully reviewed to assure that no significant patient areas are in the side scatter region.

1989-06-01

147

Ultrastructural effect of gamma radiation on grass shrimps (Penaeus monodon Fabricius)  

Energy Technology Data Exchange (ETDEWEB)

The effect of ionizing radiation (2, 5, and 10 KGy of gamma rays) on muscle ultrastructure of grass shrimps (Penaeus monodon Fabricius) tails at ambient or frozen (-18{sup 0}C) temperature was investigated by transmission electron microscopy (TEM). No significant change was found in muscle ultrastructure of shrimp meat irradiated at doses of 2 or 5 KGy and then stored at 4{sup 0}C for 0 and 8 days. However, in shrimps which were irradiated at ambient temperature at a dose of 10 KGy, the margin of A-band of the myofibrils in longitudinal sections exhibited an irregular zig-zag pattern. In cross section some myosin filaments in the A-band regions were missing. A possible interpretation of these results would be that 10 KGy gamma irradiation dose at ambient temperature depolymerized myosin in the A-band from the tail of thick filament. Actin damage was also observed in some cross sections. ...

1990-01-01

148

Ultrastructural effect of gamma radiation on grass shrimps (Penaeus monodon Fabricius)  

International Nuclear Information System (INIS)

The effect of ionizing radiation (2, 5, and 10 KGy of gamma rays) on muscle ultrastructure of grass shrimps (Penaeus monodon Fabricius) tails at ambient or frozen (-18"0C) temperature was investigated by transmission electron microscopy (TEM). No significant change was found in muscle ultrastructure of shrimp meat irradiated at doses of 2 or 5 KGy and then stored at 4"0C for 0 and 8 days. However, in shrimps which were irradiated at ambient temperature at a dose of 10 KGy, the margin of A-band of the myofibrils in longitudinal sections exhibited an irregular zig-zag pattern. In cross section some myosin filaments in the A-band regions were missing. A possible interpretation of these results would be that 10 KGy gamma irradiation dose at ambient temperature depolymerized myosin in the A-band from the tail of thick filament. Actin damage was also observed in some cross sections. ...

149

Evaluation of Mechanical Properties and Microstructure in Ion-Irradiated Surface Layer  

Science.gov (United States)

Target vessel materials used in spallation neutron source will be exposed to proton and neutron irradiation and mercury immersion environments. In order to evaluate the surface degradation of the vessel candidate materials due to such environment, the triple-ion beam irradiation taking the spallation reaction into account and mercury immersion tests were carried out. Mechanical properties of the gradient surface layer were evaluated by the inverse analysis with multi-layer model that considers distribution of surface characteristic was applied to the load and depth curves measured by using the instrumented indentation machine. Transmission electron microscopic observations were performed to evaluate the changes of microstructure in irradiated surface layer using focused ion-beam cut micro-specimen. The mechanical properties distributions in the surface layer were evaluated quantitatively and the changes ...

2005-01-01

150

Isolating the effect of radiation-induced segregation in irradiation-assisted stress corrosion cracking of austenitic stainless steels  

International Nuclear Information System (INIS)

Post-irradiation annealing was used to help identify the role of radiation-induced segregation (RIS) in irradiation-assisted stress corrosion cracking (IASCC) by preferentially removing dislocation loop damage from proton-irradiated austenitic stainless steels while leaving the RIS of major and minor alloying elements largely unchanged. The goal of this study is to better understand the underlying mechanisms of IASCC. Simulations of post-irradiation annealing of RIS and dislocation loop microstructure predicted that dislocation loops would be removed preferentially over RIS due to both thermodynamic and kinetic considerations. To verify the simulation predictions, a series of post-irradiation annealing experiments were performed. Both a high purity 304L (HP-304L) and a commercial purity 304 (CP-304) stainless steel alloy were irradiated with 3.2 MeV protons at ...

2002-04-01

151

Study of penetration depth for V"+ with low energy implanted in peanut seeds  

International Nuclear Information System (INIS)

The penetration depth and concentration distribution for vanadium ions with low energy implanted into the dry peanut seeds is determined by scanning electron microscope and X-ray energy dispersion spectrometer. The results show that the depth-concentration distribution is a Gaussian distribution with a long tail and the maximum penetration depth is about 13.6 #mu#m for V"+ with 200 keV in cotyledon of the peanut. The experimental result of the implanted V"+ range in the peanut seeds is compared with the calculating value of the TRIM95

2002-11-01

152

Studies of Plasma Confinement in GOL-3 Multi-mirror Trap  

International Nuclear Information System (INIS)

Recent results of the experiments at GOL-3 facility are presented. Plasma with a density of 1014...1016 cm-3 is confined in a 12-meter-long solenoid, which comprises 55 corrugation cells with mirror ratio Bmax/B min=4.8/3.2 T. The plasma is heated up to 2...4 keV temperature by a high power relativistic electron beam (?1 MeV, ? 330 kA, ?8?s, ?120 kJ) injected through one of the ends. Mechanism of experimentally observed fast ion heating, issued of plasma stability and confinement are discussed.

2006-01-01

153

Observation of a surface peak in low energy implant depth profiles in silicon  

Energy Technology Data Exchange (ETDEWEB)

In situ Auger sputter depth profiles of saturation implants of 3 keV N/sub 2//sup +/ in silicon at room temperature exhibit a sharp peak in the nitrogen concentration in the outermost layers, followed by a monotonic decrease. No broad plateau was observed. The energy of the Auger line corresponding to the Si(2p) core electron excitation, monitored throughout the profiling, exhibits a chemical shift of up to 7 eV at the surface peak concentration. Inert gas ion post-bombardment of unsaturated implants significantly modifies the profile, and supports the suggestion that the surface peak arises through radiation enhanced diffusion of implanted atoms.

1984-03-01

154

Angular scattering in electron capture and loss D/sup -/ beam formation processes  

Energy Technology Data Exchange (ETDEWEB)

The development of high energy (> 150 keV) neutral beams for heating and fueling magnetic fusion devices depends on the ability to produce well-collimated negative ion beams. The double capture charge-exchange technique is a known, scalable method. In order to maximize the overall efficiency of the process and to achieve the desired beam characteristics, it is necessary to examine the optical qualities of the beams as well as the total efficiency of beam production. A combined modeling and experimental study of the angular scattering effects in negative ion formation and loss processes has therefore been undertaken.

1980-01-01

155

Nanostructuring and hardening of LiF crystals irradiated with 3?15 MeV Au ions  

British Library Electronic Table of Contents (United Kingdom)

Modifications of the structure and mechanical properties in LiF crystals irradiated with MeV-energy Au ions have been studied using nanoindentation, atomic force microscopy and optical spectroscopy. The nanostructuring of crystals under a high-fluence irradiation (above 1013 ions/cm2)?was?observed. Nanoindentation tests show a strong ion-induced increase of hardness (up?to 150?200%), which is related to the high volume concentration of complex color centers, defect aggregates, dislocation loops and grain boundaries acting as strong barriers for dislocations. From the?depth profiling of the hardness and energy loss it follows that both nuclear and electronic stopping mechanisms of MeV Au ions contribute to the creation of damage and hardening. Whereas the electronic stopping is dominating i...

2011-01-01

156

Lorentz transmission electron microscopy investigation of magnetically patterned Co/Pt multilayers  

Energy Technology Data Exchange (ETDEWEB)

The switching behavior of magnetic patterns prepared by ion irradiation was investigated. Co/Pt multilayers with perpendicular anisotropy and large out-of-plane coercivities 5-6 kOe were grown on electron transparent SiN windows. Regularly spaced 1 micron sized regions, were magnetically pattered via ion beam irradiation through a stencil mask. Lorentz TEM was used to observe in-situ magnetization reversal processes of irradiated regions under well-defined applied magnetic fields. When the in-plane field was increased, domain wall motion was observed, resulting in the alignment of the patterns with the direction of the applied field. The switching mechanism of the in-plane patterns was by domain wall motion.

2000-08-01

157

Magnetic moment of the three-quasiparticle state in /sup 177/Ta  

Energy Technology Data Exchange (ETDEWEB)

An experimental investigation was made of the ..gamma..-transitions feeding or de-exciting the 1355 keV isomeric state in /sup 177/Ta. The E2/M1 mixing ratios for the 311 keV interband transition from the isomer and for the 271 keV and the 295 keV intraband transitions within the rotational band on the isomer were determined to be delta = 0.29sup(+0.11)sub(-0.06), 0.25sup(+0.05)sub(-0.03) and 0.30sup(+0.06)sub(-0.08), respectively, employing combined measurements of the linear polarization and angular distribution of the ..gamma..-ray with the aid of conversion electron measurements. Spin and parity assignments of the isomer were confirmed to be 21/2/sup -/. The half-life of the isomer was remeasured to be Tsub(1/2) = 5.0 +- 0.2 ..mu..s and the magnetic moment was found to be ..mu.. = 0.080 +- 0.014 ..mu..sub(N). The gsub(K) and gsub(R) factors for the band on the isomer were ...

1982-06-07

158

Magnetic moment of the three-quasiparticle state in "1"7"7Ta  

International Nuclear Information System (INIS)

An experimental investigation was made of the #gamma#-transitions feeding or de-exciting the 1355 keV isomeric state in "1"7"7Ta. The E2/M1 mixing ratios for the 311 keV interband transition from the isomer and for the 271 keV and the 295 keV intraband transitions within the rotational band on the isomer were determined to be delta = 0.29sup(+0.11)sub(-0.06), 0.25sup(+0.05)sub(-0.03) and 0.30sup(+0.06)sub(-0.08), respectively, employing combined measurements of the linear polarization and angular distribution of the #gamma#-ray with the aid of conversion electron measurements. Spin and parity assignments of the isomer were confirmed to be 21/2"-. The half-life of the isomer was remeasured to be Tsub(1/2) = 5.0 +- 0.2 #mu#s and the magnetic moment was found to be #mu# = 0.080 +- 0.014 #mu#sub(N). The gsub(K) and gsub(R) factors for the band on the isomer were deduced separately to be ...

159

Cryo-irradiation as a terminal method for the sterilization of drug aqueous solutions  

British Library Electronic Table of Contents (United Kingdom)

The aim of this study is to evaluate the specificities of the irradiation of drugs in frozen aqueous solution. The structures of the degradation products were determined to gain insight into the radiolysis mechanisms occurring in frozen aqueous solutions. Metoclopramide hydrochloride and metoprolol tartrate were chosen as models. The frozen solutions were irradiated at dry ice temperature by high energy electrons at various doses. The drug purity (chemical potency) and the radiolysis products were quantified by HPLC-DAD. Characterization of the degradation products was performed by LC-APCI-MS-MS. The structures of the radiolysis products detected in irradiated frozen aqueous solutions were compared to those detected in solid-state and aqueous solutions (previous studies). For both metoclop...

2008-01-01

160

Study of the electron beam irradiation effect on some properties of aromatic aliphatic copolyester films; Estudo do efeito da radiacao por feixe de eletrons nas propriedades de filmes de copoliester alifatico aromatico  

Energy Technology Data Exchange (ETDEWEB)

Biodegradable and green plastics are the new tendency in the world. The effect of the electron beam irradiation in aromatic aliphatic copolyester and the blend with corn starch films (Ecoflex{sup R} and Ecobras{sup R}) were studied by tensile strength at break, elongation at break, Scanning Electronic Microscopy (SEM), Fourier Transform Infrared Spectroscopy (FT-IR), Differential Scanning Calorimetry (DSC), crosslinking degree and biodegradability. The measurements in both, the machine direction and the transverse direction were made for mechanical tests. It was found that, the electron irradiation caused an increase in the strength at break of the blend with corn starch film, when doses of up to 10 kGy were applied. A significant decrease of the elongation at break of the blend with corn starch was observed at doses of 10 kGy and 40 kGy. It was not found important change in tensile ...

2008-07-01

161

Study of the electron beam irradiation effect on some properties of aromatic aliphatic copolyester films  

International Nuclear Information System (INIS)

Biodegradable and green plastics are the new tendency in the world. The effect of the electron beam irradiation in aromatic aliphatic copolyester and the blend with corn starch films (Ecoflex"R and Ecobras"R) were studied by tensile strength at break, elongation at break, Scanning Electronic Microscopy (SEM), Fourier Transform Infrared Spectroscopy (FT-IR), Differential Scanning Calorimetry (DSC), crosslinking degree and biodegradability. The measurements in both, the machine direction and the transverse direction were made for mechanical tests. It was found that, the electron irradiation caused an increase in the strength at break of the blend with corn starch film, when doses of up to 10 kGy were applied. A significant decrease of the elongation at break of the blend with corn starch was observed at doses of 10 kGy and 40 kGy. It was not found important change in tensile ...

162

Particle emission from low energy proton bombardment of TiH{sub 2} and TiD{sub 2}  

Energy Technology Data Exchange (ETDEWEB)

TiH{sub 2} and TiD{sub 2} thick targets were bombarded with 100 to 200 keV protons. Evidence for nuclear reactions was obtained by means of a surface barrier particle detector. Proton irradiation of TiD{sub 2} produced the following observations: {alpha} particle emission identified as (p, {alpha}) reactions from {sup 11}B and {sup 7}Li impurities in the target at ppm concentrations; and {approx}3 MeV proton and {approx}1 MeV triton emission from secondary D-D reactions caused by elastic scattering of the primary proton with a target deuteron. A 3.9 MeV {alpha} particle peak measured by others was not observed. (author)

2002-03-01

163

Fourier analysis of energy transfer data obtained by simulating a 14-MeV #alpha#-particle in water  

International Nuclear Information System (INIS)

Data from Monte Carlo transport codes are used to model radiobiological effects. We previously reported the Fourier analysis of ionization data generated by simulating a 500-keV proton traversing water. Here, we extend Fourier analysis to energy transfer data of another radiation type, a 14-MeV #alpha#-particle. A radiobiological model based on this frequency-domain analysis views cell as an information processing system . It lends itself naturally to traditional engineering analyses. One engineering principle-the output response of a linear system to random signal-is applied here to explain the fact that there is measurable difference in the magnitude of the biological effectiveness when a given biological system is irradiated with two different radiation types of the same Linear Energy Transfer (LET).

2010-01-15

164

Ar/sup +/ ion beam induced silicide formation mechanism at the Pf-Si interface  

Energy Technology Data Exchange (ETDEWEB)

Evaporated palladium films of 45 nm thickness on Si(111) were irradiated using 78 keV Ar/sup +/ ions with doses in the range of 1 x 10/sup 15/ to 1.5 x 10/sup 16/ cm/sup -2/ for the purpose of studying silicide formation. Rutherford backscattering analysis shows that intermixing has occurred across the Pd-Si interface at room temperature. The mixing behaviour increases with increasing dose of the bombarding ions, which agrees well with a theoretical model of isotropic cascade mixing for palladium, and radiation-enhanced diffusion associated with an interstitial mechanism for silicon.

1989-01-01

165

Correlation between tensile property and micro-hardness in reduced activation ferritic/martensitic steel irradiated at 573 K  

International Nuclear Information System (INIS)

Full text of publication follows: Radiation hardening and embrittlement due to high-energy neutron radiation around 623 K are the important issues on reduced-activation ferritic/martensitic (RAF/M) steels. It is expected that the improvement of radiation hardening might be one of effective ways to control the mechanical properties of RAF/M after irradiation. It has been reported that the weld joint has less hardening than the base metal from the tensile test results of TIG weldments irradiated in HFIR. This report indicated that radiation hardening can be reduced by the optimization of heat treatment condition for F82H. The purposes of this study are to establish the condition of heat treatment for minimum of radiation hardening in F82H steel using Neutron/Ion-irradiation and to examine a correlation between tensile property and micro-hardness before/after irradiation. The materials used in this study ...

2007-12-10

166

The X-ray Halo of G21.5-0.9  

CERN Document Server

The emission of the plerion G21.5-0.9 appears more extended in X rays than in radio. This is an unexpected result because it would imply that short-lived X-ray electrons may reach distances even larger than radio electrons. Applying an empirical relationship between dust scattering optical depth and photoelectric column density, the measured column density leads to a large optical depth at 1 keV, of about 1. Therefore we investigate the hypothesis that the detected halo be an effect of dust scattering, re-analyzing an Cal/PV XMM-Newton observation of G21.5-0.9 and critically examining it in terms of a dust scattering model. We also present a spectral analysis of a prominent extended feature in the northern sector of the halo.

2003-01-01

167

Electronics Personal Dosemeter (EPD-N) Test and Evaluation Report  

Energy Technology Data Exchange (ETDEWEB)

Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization then used at another site.

2003-04-08

168

Electronic structure, Compton profiles and optical properties of TaC and TaN  

International Nuclear Information System (INIS)

Isotropic Compton profiles of TaC and TaN have been measured for the first time, at an intermediate resolution, using 662 keV #gamma#-radiation. Energy bands, density of states and Fermi surface topology of TaC and TaN have been computed using linear combination of atomic orbitals with density functional theory and full potential linearised augmented plane wave method. Both band structure calculations predict the metallic character of TaC and TaN. The electron momentum densities calculated using various approaches of density functional theory are compared with the present measurements. On the basis of Mulliken's population, it is also seen that TaC has more covalent bonding than TaN. The optical properties computed using full potential linearised augmented plane wave method are explained in terms of intraband transitions.

2010-11-01

169

Atomic processes in high temperature plasmas  

International Nuclear Information System (INIS)

Much theoretical and experimental efforts have been expended in recent years to study those atomic processes which are specially relevant to understanding high temperature laboratory plasmas. For magnetically confined fusion plasmas, the temperature range of interest spans from the hundreds of eV at plasma edges to 10 keV at the center of the plasma, where most of the impurity ions are nearly fully ionized. These highly stripped ions interact strongly with electrons in the plasma, leading to further excitation and ionization of the ions, as well as electron capture. Radiations are emitted during these processes, which easily escape to plasma container walls, thus cooling the plasma. One of the dominant modes of radiation emission has been identified with dielectronic recombination. This paper reviews this work.

1990-01-01

170

A principle of charged particle trapping by RF electromagnetic field in the spherical cavity  

Energy Technology Data Exchange (ETDEWEB)

A new principle of particle trapping in the simple spherical cavity using both electric and magnetic components of radiofrequency electromagnetic field is proposed. The electric component of H {sub 12} oscillating mode drives the fast particle oscillations, while the magnetic component synchronously bends the trajectories to the cavity center. A specially developed theory of particle stability predicts dense and energetic electron cluster in the trap. Numerical simulations of particle dynamics in the complete electromagnetic field taking into account both space charge and particle-induced magnetic field are in good agreement with the analytic results, giving a density of 2.6*10{sup 1} electrons/cm{sup 3} and an average kinetic energy of around 30 keV at an operating frequency of 3 GHz. Being used at lower frequency, spherical cavity can trap protons and heavier ions too, but with lower density and kinetic energy.

2005-11-21

171

Weekly total skin electron beam therapy for mycosis fungoides and other cutaneous lymphomata: further experience.  

UK PubMed Central (United Kingdom)

Lymphomatous processes involving the skin can be managed effectively by total skin electron beam irradiation. A technique using weekly doses (400 rad for each of 6 successive weeks) has been employed...Full Text Available

1975-03-01

172

Early Experience in Using an 18 MeV Linear Accelerator for Mycosis Fungoides at Howard University Hospital  

UK PubMed Central (United Kingdom)

This paper describes the problems and solutions in using 18 MeV linear accelerator, with minimum 6 MeV electron capability, for total skin irradiation for mycosis fungoides. The 6 MeV electron energy...Full Text Available

1977-04-01

173

Bullous pemphigoid after radiation therapy  

Energy Technology Data Exchange (ETDEWEB)

Electron beam therapy applied to a lymph node metastasis from a squamous cell carcinoma was followed by the development of histologically and immunologically typical bullous pemphigoid, the lesions being initially strictly confined to the irradiation area. This observation suggests that the bullous pemphigoid antigen may be altered or unmasked by electron beam radiotherapy, leading subsequently to the production of autoantibodies. The disease in this case effectively responded to the administration of tetracycline and niacinamide, a therapeutic regimen described recently.

1988-02-01

174

Pre-irradiation technique for processing of oil palm fruit bunch fibers - polypropylene composites  

International Nuclear Information System (INIS)

Researches on oil palm empty fruit bunch (EFB) fibers and thermoplastic composites have been carried out by many workers in the last decade. The main focus was to enhance the properties of the resultant composites in view of the incompatibility of the two components. Thus, efforts have been made to enhance their properties by using coupling agents, treating the fibers and modifying the matrices. In this study, the effects of electron beam (EB) irradiation and some reactive additives (RAs) on the mechanical properties of EFB-PP (polypropylene) composites were evaluated. Different modes of irradiation were investigated. Mono, di and tri functional of monomers of RAs were used. irradiating PP alone, compared to irradiating the EFB fibers or irradiating both components, gave optimum properties for EFB-PP composites. Further, improvements of the properties of the ...

2002-06-25

175

Physical properties of wood-polyester composites prepared by an electron beam accelerator  

Energy Technology Data Exchange (ETDEWEB)

Polyester WPC (wood-polymer composite) systems are one of the promising materials for multiple uses increasing the mechanical properties, provided that their dimensional stability can be improved. Possibility was pursued for the improvement in the dimensional stability of the polyester WPC systems prepared by electron beam irradiation. The impregnation of the mixture of polyester and monomer into both oven-dried beech veneers and preswollen wood was followed by mutual irradiation process. Polymerization was carried out at total dosage of 6 Mrad to the respective surfaces of samples by an electron beam accelerator, and the reaction was completed by heating at 80 deg C for 24 hr. The dimensions of the samples were measured primarily in the tangential direction, and their dynamic modulus and loss modulus were measured by a Rheovibron DDV-2 and the vibrating reed method. The results and the discussion are ...

1981-01-01

176

Physical properties of wood-polyester composites prepared by an electron beam accelerator  

International Nuclear Information System (INIS)

Polyester WPC (wood-polymer composite) systems are one of the promising materials for multiple uses increasing the mechanical properties, provided that their dimensional stability can be improved. Possibility was pursued for the improvement in the dimensional stability of the polyester WPC systems prepared by electron beam irradiation. The impregnation of the mixture of polyester and monomer into both oven-dried beech veneers and preswollen wood was followed by mutual irradiation process. Polymerization was carried out at total dosage of 6 Mrad to the respective surfaces of samples by an electron beam accelerator, and the reaction was completed by heating at 80 deg C for 24 hr. The dimensions of the samples were measured primarily in the tangential direction, and their dynamic modulus and loss modulus were measured by a Rheovibron DDV-2 and the vibrating reed method. The results and the discussion are ...

1980-09-01

177

Absolute detection efficiency of radiation detecting system for gamma-ray from sources with high activity  

International Nuclear Information System (INIS)

In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the "1"3"7Cs-source with 10.4 GBq and "6"0Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form "1"3"7 Cs 1173.23 and 1332.51 keV"6"0 Co sources, and 14 peaks of "1"3"4Cs and "1"5"4Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show that the detection efficiency of gamma ...

2003-10-01

178

Micro and nano patterning by focused ion beam enhanced adhesion  

International Nuclear Information System (INIS)

We report a new method of generating nano and micro patterns using focused ion beam (FIB) induced adhesion. The method utilizes selective irradiation of thin metallic films grown on substrates by focused ion beam followed by peel off. After peel off of the irradiated thin film it is observed that the ion beam scanned portions are retained on the substrate, creating nano and micro patterns. The method is suitable for materials of which the adhesion to the substrate can be improved by ion bombardment. The phenomenon has been demonstrated by creating gold nano patterns of different shapes and sizes ranging from 500 nm to 5 #mu#m on SiO_2-Si substrate using 10-30 keV Ga FIB at beam currents up to 10 pA. The mechanism involved in the process has been discussed. The technique could be utilized to prepare micro and nano patterns of thin films deposited on an appropriate substrate for optical, plasmonic and sensor related ...

2009-05-01

179

Effect of Al and Be ions pre-implantation on formation and growth of helium bubbles in SiC/SiC composites  

Energy Technology Data Exchange (ETDEWEB)

The effect of Al and Be ions pre-implantation on microstructural change and, the formation and growth of He bubbles in SiC/SiC composite was investigated. Four kinds of ion implanted specimens were prepared with 100 appm Al, 1000 appm Al, 100 appm Be and 1000 appm Be implanted. No microstructural change was observed in the matrices and fibers of SiC/SiC composites implanted with Al or Be ions up to 1000 appm. The un-implanted and Al or Be pre-implanted SiC/SiC composites were simultaneously irradiated to 10 dpa using triple ion-beams (6.0-MeV Si{sup 2+}, 1.0-MeV He{sup +} and 340-keV H{sup +}) at 1000 deg. C. Helium bubbles were formed in every matrix and fiber irradiated by triple ion-beams. The size of He bubbles in the matrix was increased by implanting Al or Be ions and increased with increasing amount of implanted Al or Be ions. The size of He bubbles in the fiber was slightly increased by implanting Al or Be ions. ...

2007-03-15

180

Effect of Al and Be ions pre-implantation on formation and growth of helium bubbles in SiC/SiC composites  

International Nuclear Information System (INIS)

The effect of Al and Be ions pre-implantation on microstructural change and, the formation and growth of He bubbles in SiC/SiC composite was investigated. Four kinds of ion implanted specimens were prepared with 100 appm Al, 1000 appm Al, 100 appm Be and 1000 appm Be implanted. No microstructural change was observed in the matrices and fibers of SiC/SiC composites implanted with Al or Be ions up to 1000 appm. The un-implanted and Al or Be pre-implanted SiC/SiC composites were simultaneously irradiated to 10 dpa using triple ion-beams (6.0-MeV Si"2"+, 1.0-MeV He"+ and 340-keV H"+) at 1000 deg. C. Helium bubbles were formed in every matrix and fiber irradiated by triple ion-beams. The size of He bubbles in the matrix was increased by implanting Al or Be ions and increased with increasing amount of implanted Al or Be ions. The size of He bubbles in the fiber was slightly increased by implanting Al or Be ions. These results ...

2007-03-01

181

Nondestructive transfer of complex molecular systems of various origins into aerosol phase by means of submillimeter irradiation of free-electron laser (FEL) of the Siberian center for photochemical research  

International Nuclear Information System (INIS)

Original investigations of ablation of minerals, fullerene-like compounds, polymers and complicated biological macromolecules under the action of submillimeter radiation of the free-electron laser (FEL) developed and built at Budker Institute of Nuclear Physics [V.P. Bolotin et al., First experiments on high-power Novosibirsk terahertz free-electron laser, Budker INP, 2005, p. 37 [1

2007-05-21

182

High resolution transmission electron microscopy of partial states of oxygen order in YBa_2Cu_3O_z  

International Nuclear Information System (INIS)

This paper reports on high resolution electron microscopy used to investigate the effect of electron irradiation induced oxygen loss on the states of partial order in YBa_2Cu_3O_z. Contrast effects visible in the [001] zone image as a result of the degree of the out-of-plane correlation of these ordered states are investigated. Using statistical simulations to aid in the analysis of the HREM images, an interpretation based on a kinetically limited evolution of the variation of long range [001] ordering is proposed.

1990-04-16

183

Effect of electron irradiation on domain wall pinning defects in 50-50 NiFe  

International Nuclear Information System (INIS)

A magnetic measuring technique, which sorts out defects according to a distribution function n, was used to study the influence of electron irradiation on 50-50 NiFe. The distribution function is determined in terms of the maximum force f/subm/ that a defect can exert on a forward moving domain wall, or equivalently, the range z_0, which is the distance the mean position of the wall may move past the defect before the wall snaps free from the pinning action of the defect. The range and maximum force are related by a spring constant k, viz., f/subm/=kz_0. The quantity n (z_0) dz_0 gives the number of defects per unit volume having a range between z_0 and z_0+dz_0. Distribution functions were determined before and after electron irradiation. The irradiation was for 100 min with 18-MeV electrons with a dose of 1.1times10"1"7 e/cm"2. Following ...

184

AECL IMPELA electron beam industrial irradiators  

International Nuclear Information System (INIS)

A family of industrial irradiators is being developed by AECL to cover an electron-beam energy range from 5 to 18 MeV at beam powers between 20 and 250 kW. The IMPELA family of irradiators is designed for push button, reliable operation. The major irradiator components are modular, allowing for later upgrades to meet increased demands in either electron or X-ray mode. Interface between the control system, irradiator availability and dose quality assurance is in conformance with the most demanding specifications. The IMPELA irradiators use a klystron-driven, standing-wave, L-band accelerator structure with direct injection from a rugged, triode electron gun. Direct control of the accelerating field during the beam pulse ensures constant output beam energy, independent of beam power. The first member of the family, the ...

185

Electron Capture Dissociation Implementation Progress in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry  

British Library Electronic Table of Contents (United Kingdom)

Successful electron capture dissociation (ECD) Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) applications to peptide and protein structural analysis have been enabled by constant progress in implementation of improved electron injection techniques. The rate of ECD product ion formation has been increased to match the liquid chromatography and capillary electrophoresis timescales, and ECD has been combined with infrared multiphoton dissociation in a single experimental configuration to provide simultaneous irradiation, fast switching between the two techniques, and good spatial overlap between ion, photon, and electron beams. Here we begin by describing advantages and disadvantages of the various existing electron injection techniques for ECD in FT-ICR MS. We next ...

2008-01-01

186

Surface modification/alloying using intense pulsed electron beam as a tool for improving the corrosion resistance of steels exposed to heavy liquid metals  

British Library Electronic Table of Contents (United Kingdom)

The alloying of steel surface with aluminum (Al) using Microsecond-pulsed Intense Electron Beams (MIEB-Al) was developed and optimized in order to be used for improving the corrosion resistance of the 316, 1.4970 and T91 steels, exposed to liquid Pb and Pb-Bi-eutectic. The procedure consists in two steps: (i) coating the steel surface with Al or an Al-containing alloy layer and (ii) melting the coating layer and the steel surface layer using intense pulsed electron beam. In order to cover the steel surface with an homogeneous and crack-free Al-alloyed layer, the following experimental conditions are required: Al coating thickness range 5-10mm, electron kinetic energy 120keV; pulse duration 30ms; energy density 40-45J/cm2; number of pulses 2-3. Using the mentioned procedure, the corrosion r...

2011-01-01

187

The effect of boron implant energy on transient enhanced diffusion in silicon  

Energy Technology Data Exchange (ETDEWEB)

Transient enhanced diffusion (TED) of boron in silica after low energy boron implantation and annealing was investigated using boron-doping superlattices (DSLs) grown by low temperature molecular beam epitaxy. Boron ions were implanted at 5, 10, 20, and 40 keV at a constant dose of 2{times}10{sup 14}/cm{sup 2}. Subsequent annealing was performed at 750{degree}C for times of 3 min, 15 min, and 2 h in a nitrogen ambient. The broadening of the boron spikes was measured by secondary ion mass spectroscopy and simulated. Boron diffusivity enhancement was quantified as a function of implant energy. Transmission electron microscopy results show that {l_angle}311{r_angle} defects are only seen for implant energies {ge}10 keV at this dose and that the density increases with energy. DSL studies indicate the point defect concentration in the background decays much slower when {l_angle}311{r_angle} defects are present. These results ...

1997-02-01

188

Measurement of the /SUP 242m/ Am neutron fission cross section  

Energy Technology Data Exchange (ETDEWEB)

The fission cross section of /SUP 242m/ Am has been measured from 0.005 eV to 20 MeV using time-of-flight techniques at the Oak Ridge Electron Linear Accelerator. A hemispherical plate fission ionization chamber with five pairs of plates contained three deposits totaling 507 ..mu..g of /SUP 242m/ Am, one deposit of 168 ..mu..g /sup 235/U, and a ''weightless'' deposit of /sup 252/Cf, which served as a monitor of chamber performance. The fission of /sup 235/U, served as the cross-section standard for energies above 101 keV while /sup 6/Li(n,..cap alpha..), normalized to /sup 235/U fission in the 7.8- to 11.0-eV interval, served as a shape standard below 101 keV. Approximately 360 h of data were obtained at a flight path distance of 9.1 m, primarily with 40-ns bursts. Particular attention was paid to correction of backgrounds, especially inscattered-neutron-induced events. The fission ...

1983-05-01

189

Measurement of the /SUP 242m/ Am neutron fission cross section  

International Nuclear Information System (INIS)

The fission cross section of /SUP 242m/ Am has been measured from 0.005 eV to 20 MeV using time-of-flight techniques at the Oak Ridge Electron Linear Accelerator. A hemispherical plate fission ionization chamber with five pairs of plates contained three deposits totaling 507 #mu#g of /SUP 242m/ Am, one deposit of 168 #mu#g "2"3"5U, and a ''weightless'' deposit of "2"5"2Cf, which served as a monitor of chamber performance. The fission of "2"3"5U, served as the cross-section standard for energies above 101 keV while "6Li(n,#alpha#), normalized to "2"3"5U fission in the 7.8- to 11.0-eV interval, served as a shape standard below 101 keV. Approximately 360 h of data were obtained at a flight path distance of 9.1 m, primarily with 40-ns bursts. Particular attention was paid to correction of backgrounds, especially inscattered-neutron-induced events. The fission resonance integral was found to be 1800 + or - 65 b.

190

Energy resolution of scintillation detectors readout with large area avalanche photodiodes and photomultipliers  

International Nuclear Information System (INIS)

The energy resolution of small NaI(Tl), CsI(Tl), BGO, GSO, YAP and LSO crystals has been studied using 16 mm diameter large area avalanche photodiodes (LAAPD) and a 52 mm diameter photomultiplier. The best result of 4.8% for 662 keV #gamma#-rays from a "1"3"7Cs source was obtained with a 9 mm in diameter by 9 mm high CsI(Tl) scintillator coupled to an LAAPD. Measuring the number of primary electron-hole pairs produced in the LAAPD and photoelectrons in the photomultiplier, as well as the noise contribution of the LAAPD, allowed a quantitative discussion of the results. The energy resolutions measured with LAAPDs are comparable to, or significantly better (at certain emission wavelengths) than, those obtained with the photomultiplier. At energies above 100 keV the energy resolution measured with the majority of crystals and the LAAPD was weakly affected by the photodiode noise contribution. The advantages and limitations of ...

1998-06-01

191

Effect of the Ge preamorphization dose on boron diffusion and defect evolution in silicon  

Energy Technology Data Exchange (ETDEWEB)

In this paper, we study the effect of the Ge{sup +} preamorphization dose on boron diffusion and on the thermal evolution of end of range (EOR) defects during annealing. Amorphizations were carried out by implanting Ge{sup +} at 150 keV to doses ranging from 1x10{sup 15} to 8x10{sup 15} ions/cm{sup 2}. Boron was subsequently implanted at 3 keV with a dose of 1x10{sup 14} ions/cm{sup 2}. Rapid thermal annealing (RTA) was performed for various time/temperature combinations in nitrogen ambient. Secondary ion mass spectroscopy (SIMS) and transmission electron microscopy (TEM) were used to study boron diffusion and defect evolution, respectively. We have found that after a given annealing, both the defect size and boron diffusivity are independent on the Ge ion dose. Increasing this dose only results in an increase of the defect density. These results are discussed and definitely show that EOR defects are involved in a ...

2002-01-01

192

Effect of the Ge preamorphization dose on boron diffusion and defect evolution in silicon  

International Nuclear Information System (INIS)

In this paper, we study the effect of the Ge"+ preamorphization dose on boron diffusion and on the thermal evolution of end of range (EOR) defects during annealing. Amorphizations were carried out by implanting Ge"+ at 150 keV to doses ranging from 1x10"1"5 to 8x10"1"5 ions/cm"2. Boron was subsequently implanted at 3 keV with a dose of 1x10"1"4 ions/cm"2. Rapid thermal annealing (RTA) was performed for various time/temperature combinations in nitrogen ambient. Secondary ion mass spectroscopy (SIMS) and transmission electron microscopy (TEM) were used to study boron diffusion and defect evolution, respectively. We have found that after a given annealing, both the defect size and boron diffusivity are independent on the Ge ion dose. Increasing this dose only results in an increase of the defect density. These results are discussed and definitely show that EOR defects are involved in a quasi-conservative Ostwald ripening ...

2002-01-01

193

Absolute differential cross sections for the scattering of kilo-electron-volt O atoms  

International Nuclear Information System (INIS)

This paper reports measurements of absolute differential cross sections for the direct scattering of oxygen atoms by He, Ne, Ar, Kr, Xe, H_2, N_2, O_2, CO, CO_2, H_2O, SO_2, NH_3, CH_4, CF_4, and SF_6 targets. The measured cross sections include contributions from all elastic and inelastic processes that result in a fast neutral oxygen atom product. Cross sections are presented for 0.5- and 1.5-keV projectile energies over the laboratory angular range 0.2 degree endash 5 degree. When compared in the center-of-mass reference frame, these cross sections exhibit a high degree of similarity in both amplitude and angular dependence. The cross sections for N_2, CO, CO_2, and H_2O are inverted using a partial-wave analysis to yield empirical interaction potentials, which can then be used to extrapolate the measurements down to lower energies. Using these potentials, cross sections are evaluated at 0.1 keV. copyright 1996 The American Physical Society.

194

Stellar (n,#gamma#) cross sections of p-process isotopes. II. "1"6"8Yb, "1"8"0W, "1"8"4Os, "1"9"0Pt, and "1"9"6Hg  

International Nuclear Information System (INIS)

The neutron-capture cross sections of "1"6"8Yb, "1"8"0W, "1"8"4Os, "1"9"0Pt, and "1"9"6Hg have been measured by means of the activation technique. The samples were irradiated in a quasistellar neutron spectrum of kT=25 keV, which was produced at the Karlsruhe 3.7-MV Van de Graaff accelerator via the "7Li(p,n)"7Be reaction. Systematic uncertainties were investigated in repeated activations with different samples and by variation of the experimental parameters, that is, irradiation times, neutron fluxes, and #gamma#-ray counting conditions. The measured data were converted into Maxwellian-averaged cross sections at kT=30 keV, yielding 1214#+-#61, 624#+-#54, 590#+-#43, 511#+-#46, and 201#+-#11 mb for "1"6"8Yb, "1"8"0W, "1"8"4Os, "1"9"0Pt, and "1"9"6Hg, respectively. The present results either represent first experimental data ("1"6"8Yb, "1"8"4Os, and "1"9"6Hg) or could be determined with significantly ...

2010-09-01

195

Valence electronic structure of Ti, Cr, Fe and Co in some alloys from K{beta}-to-K{alpha} X-ray intensity ratio studies  

Energy Technology Data Exchange (ETDEWEB)

K{beta}-to-K{alpha} X-ray intensity ratios of Ti, Cr, Fe and Co in pure metals and in Cr{sub 0.26}Fe{sub 0.74}, Cr{sub 0.80}Co{sub 0.20} and Ti{sub 0.80}Cr{sub 0.20} alloys have been measured following excitation by 59.54 keV {gamma}-rays from a 7400 MBq (200 mCi) {sup 241}Am point-source. The valence electronic structure of Ti, Cr, Fe and Co in the samples have been evaluated by the comparison of the measured K{beta}-to-K{alpha} intensity ratios with the results of multiconfiguration Dirac-Fock calculations performed for various electronic configurations of these metals. The 3d-electron populations obtained for pure metallic Ti, Cr, Fe and Co agree well with the results of band structure calculations of Papaconstantopoulos (Handbook of band structure of elemental solids, Plenum Press, New York, 1986). Our analysis indicates significant increase of 3d-electron population of Ti, Cr ...

2002-10-01

196

Valence electronic structure of Ti, Cr, Fe and Co in some alloys from K#beta#-to-K#alpha# X-ray intensity ratio studies  

International Nuclear Information System (INIS)

K#beta#-to-K#alpha# X-ray intensity ratios of Ti, Cr, Fe and Co in pure metals and in Cr_0_._2_6Fe_0_._7_4, Cr_0_._8_0Co_0_._2_0 and Ti_0_._8_0Cr_0_._2_0 alloys have been measured following excitation by 59.54 keV #gamma#-rays from a 7400 MBq (200 mCi) "2"4"1Am point-source. The valence electronic structure of Ti, Cr, Fe and Co in the samples have been evaluated by the comparison of the measured K#beta#-to-K#alpha# intensity ratios with the results of multiconfiguration Dirac-Fock calculations performed for various electronic configurations of these metals. The 3d-electron populations obtained for pure metallic Ti, Cr, Fe and Co agree well with the results of band structure calculations of Papaconstantopoulos (Handbook of band structure of elemental solids, Plenum Press, New York, 1986). Our analysis indicates significant increase of 3d-electron population of Ti, Cr and Fe in the ...

2002-10-01

197

Radiobiology  

International Nuclear Information System (INIS)

This text-book (electronic book - multi-media CD-ROM) constitutes a course-book - author's collection of lectures. It consists of 13 lectures in which the reader acquaints with the basis of radiobiology: Introduction to radiobiology; Physical fundamentals of radiobiology; Radiation of cells; Modification of radiation damage of cells; Reparation of radiation damage of cells; Radiation syndromes and their modification; Radiation injury; Radiation damage of tissues; Effect of radiation on embryo and fetus; Biological effects of incorporated radionuclides; Therapy of acute irradiation sickness; Delayed consequences of irradiation; Radiation oncology and radiotherapy. This course-book may be interesting for students, post-graduate students of chemistry, biology, physics, medicine as well as for teachers, scientific workers and physicians. (author)

198

Neutron irradiation effect on mechanical properties of metals after preliminary hardening  

International Nuclear Information System (INIS)

Some results on mechanical property study of copper and titanium subjected to impact load and next to neutron irradiation are presented. It was shown that shock wave influence involves a substantial shape change of the stress-strain diagram and of respective mechanical characteristics. Yield- and ultimate strength were substantially increased, as well as hardness with a considerable drop of plasticity. Also a heat stability of copper and titanium specimens was studied after being treated with shock-waves and neutron radiation. Results are given of electron microscope study of titanium structure sfter explosion hardening, which caused decomposition of hydride segregations in titanium and increased dislocation density.

199

Kinetic investigations of graft copolymerization of sodium styrene sulfonate onto electron beam irradiated poly(vinylidene fluoride) films  

Energy Technology Data Exchange (ETDEWEB)

Graft copolymerization of sodium styrene sulfonate (SSS) onto electron beam (EB) irradiated poly(vinylidene fluoride) (PVDF) films was investigated to find out a simple preparation process for sulfonic acid proton exchange membranes with respect to monomer concentration, absorbed dose, temperature, film thickness and storage time. The reaction order of the monomer concentration and absorbed dose of grafting was found to be 2.84 and 1.20, respectively. The overall activation energy for graft copolymerization reaction was calculated to be 11.36 kJ/mol. The initial rate of grafting was found to decrease with an increase in the film thickness. The trapped radicals in the irradiated PVDF films remained effective in initiating the reaction without considerable loss in grafting level up to 180 days, when stored under -60 {sup o}C. The presence and distribution of polystyrene sulfonate grafts in the obtained membranes were observed ...

2011-01-15

200

Applications or radiation polymerization hardening to composites  

International Nuclear Information System (INIS)

Comprehensive investigation has been made into the application of the polymerization hardening by radiation, particularly electron beam, to the composites of polymers and other materials. The report is divided into four parts, namely 1) characteristics and problems of the reaction of curing by radiation polymerization, 2) improvement of the bonding capability of high molecular weight materials, 3) bonding by radiation, and 4) composites made by the impregnation and polymerization hardening of monomers. The first part includes the effects of dose rate, temperature rise during the hardening, the peculiarity of electron beam irradiation at high dose rate, reaction environment and additive effects. Main conclusions are as follows: caution must be taken to the amount of residual double bonds because they affect the quality of hardened polymers; the polymerization hardening reaction at high dose rate cannot be analogized by that ...

1976-01-01

201

Influence of alloying elements on the irradiation hardening and environmental sensitivity of zirconium alloys  

International Nuclear Information System (INIS)

Ten different alloys of zirconium have been tested with regard to the effect of irradiation on their mechanical properties and their sensitivity to environmentally induced failure. Two different environments were used: iodine vapour and liquid cesium with an addition of 2% cadmium. The neutron dose was 10"2"1n/cm"2 (E>1MeV) and the irradiation temperature was about 300 degrees C. All alloy additions increased the irradiation hardening. Especially notable was the large effect of titanium and tin on irradiation hardening. A limited amount of transmission electron microscopy was carried out in order to find an explanation to the effects. The testing in different environments showed that there is no clear correlation between environmental sensitivity and yield stress. For materials of similar yield stress an alloyed material tends to be more sensitive to environmental cracking than a ...

1991-08-25

202

EPR investigation of some irradiated traditional oriental spices  

International Nuclear Information System (INIS)

The X-band EPR spectra of unirradiated and "6"0 Co gamma ray irradiated cardamom (Elettaria cardamomum L. Maton, Zingiberaceae), ginger ((Zingiber officinale Rosc., Zingiberaceae), saffron (Crocus sativus L., Iridaceae), and curry have been investigated at room temperature. All unirradiated spices presented a weak resonance line with g-factors around free-electron ones, most probably due to the presence of semiquinones, previously reported to have paramagnetic properties. After gamma ray irradiation at absorbed dose up to 11.3 kGy we have noticed in all spices the presence of complex EPR spectra consisting of a superposition of at last two different paramagnetic species whose amplitude increase monotonously with the absorbed dose. A 100 deg. C isothermal annealing of 11.3 kGy irradiated samples has shown a differential reduction of amplitude of various components that form the initial spectra, but even ...

2005-09-13

203

Effects of combined electron-beam irradiation and sous-vide treatments on microbiological and other qualities of chicken breast meat  

Energy Technology Data Exchange (ETDEWEB)

The microbiological safety, refrigeration shelf-life, and nutritional quality of chicken breast meat were investigated following combined electron-beam irradiation and cooking under vacuum (sous-vide). Chicken breast meat inoculated with 10{sup 6} CFU/g of Listeria monocytogenes was irradiated with an electron beam at doses up to 3.1 kGy under vacuum in barrier bags, cooked in a boiling water bath for 3 min 45 s (previously determined to achieve an internal temperature of 71.1{sup o}C), and stored at 8{sup o}C for up to 5 weeks. Listeria was undetectable in samples treated with combined sous-vide and irradiation at 3.1 kGy, but the organism survived the sous-vide treatment without irradiation and multiplied during storage. A similar study, conducted with uninoculated chicken breast meat, revealed that the product which received both ...

1994-07-01

204

Thermoluminescence studies in lead doped KCl and KBr crystals  

International Nuclear Information System (INIS)

Lead is known to enter substitutionally in divalent state when doped in alkali halides. When irradiated at room temperature these lead centers (Pb"+"+) act as traps for electrons knocked off from the halogen ions and become Pb"+ and Pb"0 (for large doses of irradiation). These changes could be followed in the optical absorption studies. These lead-doped crystals after X-ray irradiation yield a thermoluminescence output smaller than that observed in 'pure' crystals. However, two new glow peaks are observed in additions to those due to F-centers. In KCl : Pb and Kbr : Pb crystals part of the F-center glow preceds the new glow peaks. The new peaks are attributed to the Pb"+ and Pb"0 centers. The glow peak temperatures and trap depths for these peaks an obtained by total-curve fitting method are reported. (author).

1975-02-12

205

Radiation yield of oxygen-based radicals in hyperquenched glassy water gamma-irradiated at 77 K  

Energy Technology Data Exchange (ETDEWEB)

Hyperquenching of liquid water with cooling rates of 10{sup 6}-10{sup 7} K s{sup -1} yields glassy water. Upon {gamma}-irradiation at 77 K, the only paramagnetic species accumulating in hyperquenched glassy water are the hydroxyl and hydroperoxyl radicals. There are no hydrogen atoms or electrons seen by the ESR technique. For irradiation doses up to about 70 kGy, the relative contributions of hydroxyl and hydroperoxyl radicals to the total amount of paramagnetic species remain virtually constant. The total amount of paramagnetic species, n, is sublinear in dose, d, well approximated by n=8.55x10{sup 16}d{sup 0.8} for n in spin g{sup -1} and d in kGy.

1998-12-01

206

Radiation treatment for sterilization of packaging materials  

International Nuclear Information System (INIS)

Treatment with gamma and electron radiation is becoming a common process for the sterilization of packages, mostly made of natural or synthetic plastics, used in the aseptic processing of foods and pharmaceuticals. The effect of irradiation on these materials is crucial for packaging engineering to understand the effects of these new treatments. Packaging material may be irradiated either prior to or after filling. The irradiation prior to filling is usually chosen for dairy products, processed food, beverages, pharmaceutical, and medical device industries in the United States, Europe, and Canada. Radiation effects on packaging material properties still need further investigation. This paper summarizes the work done by different groups and discusses recent developments in regulations and testing procedures in the field of packaging technology.

2007-08-01

207

Radiation hardening in neutron-irradiated polycrystalline copper: Barrier strength of defect clusters  

International Nuclear Information System (INIS)

Defect cluster formation in 14-MeV neutron irradiated polycrystalline copper has been observed by transmission electron microscopy (TEM) and correlated with the increase in yield stress. The measurements indicate that the radiation hardening component of the yield strength in polycrystals is not directly additive to the unirradiated yield strength. A transitional behavior was observed for radiation hardening at low fluences, which produces an anomalous variation of the defect cluster barrier strength with fluence. The behavior is attributed to the effect of grain boundaries on slip band transmission. An upper limit for the room temperature barrier strength of defect clusters in neutron-irradiated copper was determined to be #alpha#=0.23. (orig.).

1989-12-04

208

Preparation of AgCl Nanoparticles@Ancient Textile with Antibacterial Activity under Ultrasound Irradiation  

British Library Electronic Table of Contents (United Kingdom)

The growth of silver chloride nanoparticles on ancient textile was achieved by sequential dipping steps in alternating bath of potassium chloride and silver nitrate under ultrasound irradiation. The effect of ultrasound irradiation and sequential dipping steps in growth of the AgCl nanoparticles has been studied. These systems depicted a decrease in the particles size accompanying a decrease in the sequential dipping steps. The samples were characterized with powder X-ray diffraction (XRD) and scanning electron microscopy. XRD analyses indicated that the prepared AgCl nanoparticles on fiber were crystalline. The textile samples containing AgCl nanoparticles were tested for their antibacterial efficacy against Escherichia coli and were found to possess significant antibacterial activity.

2011-01-01

209

Photoluminescence in large fluence radiation irradiated space silicon solar cells  

Energy Technology Data Exchange (ETDEWEB)

Photoluminescence spectroscopy measurements were carried out for silicon 50{mu}m BSFR space solar cells irradiated with 1MeV electrons with a fluence exceeding 1 x 10{sup 16} e/cm{sup 2} and 10MeV protons with a fluence exceeding 1 x 10{sup 13} p/cm{sup 2}. The results were compared with the previous result performed in a relative low fluence region, and the radiation-induced defects which cause anomalous degradation of the cell performance in such large fluence regions were discussed. As far as we know, this is the first report which presents the PL measurement results at 4.2K of the large fluence radiation irradiated silicon solar cells. (author)

1997-03-01

210

On stage III and stage IV recovery of zinc after alpha-particle irradiation  

International Nuclear Information System (INIS)

Stage III and stage IV recovery have been investigated resistometrically following 6.1 MeV alpha-particle irradiation at 4.2 K. The activation energy associated with stage III shows a gradual increase from 0.35 +- 0.02 eV to 0.39 +- 0.02 eV. Stage IV (155 to 180 K) is associated with an activation energy of 0.46 +- 0.03 eV. The present results are compared with those obtained after electron and neutron irradiation. The stage III recovery kinetics are interpreted in terms of the Goesele-Seeger theory for interstitial migration in highly anisotropic hexagonal metals. Stage IV is ascribed to monovacancy migration. (author).

211

Mechanical properties of SiAlON glass surface after swift heavy-ion bombardment  

International Nuclear Information System (INIS)

A Y-Mg-Si-Al-O-N glass was submitted to swift heavy-ion bombardment at GANIL (Caen, France) and the influence of irradiation on the mechanical properties was studied. The mechanical properties of the glass were characterized both before and after irradiation. Changes in hardness, elastic modulus and fracture toughness of the near-surface irradiated layer were determined using indentation techniques. SRIM calculations allowed to estimate the ions penetration range and the energy deposition relative to electronic and nuclear interactions, which can be correlated to the experimental damaged depth. Meyer's hardness and Young's modulus decrease by about 30 %, while fracture toughness is increased by more than 40 %. (authors)

212

Irradiation of polyethylene in the presence of antioxidants  

International Nuclear Information System (INIS)

The radiation induced reactions in LDPE in the presence of phenolic type antioxidants have been studied. It was shown that various antioxidants can influence the polyethylene network formation and the radical yield in different ways. The dependence of network structure on absorbed doses was determined by gel analysis, hot-set test and extraction of antioxidants for samples irradiated with accelerated electrons. It was found that the antioxidants eluted from polyethylene in higher percentage influence polymer crosslinking to a smaller degree. The ESR studies of #gamma#-irradiated blends of polyethylene with antioxidant indicate the presence of alkyl and phenoxyl radicals. The role of antioxidant molecules on radiation induced reactions in polyethylene-antioxidant systems is considered. The correlation between the network structure and the type of additive in polyethylene is also discussed. (author).

213

Enhanced reflectance mirrors for space-borne HF laser applications  

Science.gov (United States)

Combined electron, photon, and intense UV irradiation tests have been carried out on three mirror designs, (Si, Al/sub 2/O/sub 3/)/sub 2/Ag, (Si, SiOx)nAg, and (ZnS, Al/sub 2/O/sub 3/)4Ag, to investigate their suitability for space-borne chemical laser applications. It is found that the (Si, oxide)nAg enhanced-reflectance design is a viable candidate for such applications, whereas ZnS, in combination with either ThF/sub 4/ or Al/sub 2/O/sub 3/, shows unacceptably high absorption increases at the 2.8-micron HF laser wavelength with irradiation. It is pointed out, however, that further experiments are needed to fully understand the effect of irradiation on the (Si, oxide)nAg enhanced-reflectance mirrors.

1981-01-01

214

Performance testing of selected types of electronic personal dosimeters used in Sudan  

International Nuclear Information System (INIS)

Measurements were carried out for calibration and performance testing of a set of 10 electronic personal dosimeters (EPDs) at the Secondary Standard Dosimetry Laboratory of Sudan. Calibrations were carried out at three X-ray beam qualities described in ISO standard 4037 in addition to 137Cs and 60Co gamma ray beams. The experimental was performed with EPDs mounted on ICRU Slab phantom. X-ray and ?-ray beams were characterized in terms of air kerma free-in-air which were converted to the known delivered personal dose equivalent, Hp(10) using appropriate the air kerma to personal dose equivalent conversion coefficients. Dosimeters tested showed excellent energy and angular response and relative error of indication within the recommended limit for photon energies from 65 keV to 1.25 MeV. The study showed encouraging results for using electronic dosimeters in personal dosimetry.

2010-12-01

215

K{beta}-to-K{alpha} X-ray intensity ratio studies on the changes of valence electronic structures of Ti, V, Cr, and Co in their disilicide compounds  

Energy Technology Data Exchange (ETDEWEB)

K{beta}-to-K{alpha} X-ray intensity ratios of Ti, V, Cr, and Co in pure metals and their disilicide compounds have been measured following excitation by 59.54 keV {gamma}-rays from a 200 mCi {sup 241}Am point-source. The K{beta}-to-K{alpha} intensity ratios of all these metals in the disilicide compounds are found to be less than the corresponding ratios for pure metals. Comparison of the measured K{beta}-to-K{alpha} intensity ratios for the disilicides and pure metals with the multiconfiguration Dirac-Fock calculations indicates increase of the 3d electron populations of Ti, V, Cr, and Co in the disilicides from their pure metal values suggesting the rearrangement of electrons between 3d and 4s states of the individual metal atom. This rearrangement is found to be opposite to that observed in our previously reported work on NiSi{sub 2} and CuSi{sub 2}.

1999-06-01

216

K#beta#-to-K#alpha# X-ray intensity ratio studies on the changes of valence electronic structures of Ti, V, Cr, and Co in their disilicide compounds  

International Nuclear Information System (INIS)

K#beta#-to-K#alpha# X-ray intensity ratios of Ti, V, Cr, and Co in pure metals and their disilicide compounds have been measured following excitation by 59.54 keV #gamma#-rays from a 200 mCi "2"4"1Am point-source. The K#beta#-to-K#alpha# intensity ratios of all these metals in the disilicide compounds are found to be less than the corresponding ratios for pure metals. Comparison of the measured K#beta#-to-K#alpha# intensity ratios for the disilicides and pure metals with the multiconfiguration Dirac-Fock calculations indicates increase of the 3d electron populations of Ti, V, Cr, and Co in the disilicides from their pure metal values suggesting the rearrangement of electrons between 3d and 4s states of the individual metal atom. This rearrangement is found to be opposite to that observed in our previously reported work on NiSi_2 and CuSi_2.

1999-06-01

217

Irradiation effect of high current pulsed electron beam on surface structure and mechanical properties of NiCoCrAlY  

International Nuclear Information System (INIS)

DZ4 substrates were coated with NiCoCrAlY by plasma spray and subsequently treated by high current pulsed electron beams(HCPEB) of different parameters. The surface microstructure, phase structure and high temperature oxidation resistance were studied. It has been shown that as a result of the HCPEB treatment the loose and rough structure remelted and the surface became smooth. Smooth microregion, craters and cracks appeared on the surface. The ?' phase manifolded and there was no visible thermal stress. The oxidation test at 900 degree C for 100 h showed that a more compact and successive ?-Al_2O_3 scale was formed on the surface of the samples after HCPEB irradiation, which improved the oxidation resistance of the NiCoCrAlY coatings obviously. (authors)

2009-09-01

218

Time-of-flight measurements of light molecular ions scattered at grazing incidence from a Ni(111) surface  

Energy Technology Data Exchange (ETDEWEB)

A time-of-flight mass spectrometer has been constructed to measure the energy spectra of particles scattered by 10/sup 0/ with primary energies between 200 eV and 15 keV. The energy resolution ..delta..E/E of the system is between 0.1 and 0.4%. Energy spectra of scattered molecules and their dissociation products are shown for 570 eV H/sub 2//sup +/ and 4430 eV N/sub 2//sup +/ as projectiles. Electron capture into unbound states of the neutral molecule, with perhaps some contribution from mutual scattering within the molecule, appears to explain the observed dissociation product energy spectra peak widths.

1984-03-01

219

Time-of-flight measurements of light molecular ions scattered at grazing incidence from a Ni(111) surface  

International Nuclear Information System (INIS)

A time-of-flight mass spectrometer has been constructed to measure the energy spectra of particles scattered by 10"0 with primary energies between 200 eV and 15 keV. The energy resolution #DELTA#E/E of the system is between 0.1 and 0.4%. Energy spectra of scattered molecules and their dissociation products are shown for 570 eV H_2"+ and 4430 eV N_2"+ as projectiles. Electron capture into unbound states of the neutral molecule, with perhaps some contribution from mutual scattering within the molecule, appears to explain the observed dissociation product energy spectra peak widths. (orig.).

220

Reactions of the inner surface of carbon nanotubes and nanoprotrusion processes imaged at the atomic scale  

British Library Electronic Table of Contents (United Kingdom)

Although the outer surface of single-walled carbon nanotubes (atomically thin cylinders of carbon) can be involved in a wide range of chemical reactions, it is generally thought that the interior surface of nanotubes is unreactive. In this study, we show that in the presence of catalytically active atoms of rhenium inserted into nanotubes, the nanotube sidewall can be engaged in chemical reactions from the inside. Aberration-corrected high-resolution transmission electron microscopy operated at 80?keV allows visualization of the formation of nanometre-sized hollow protrusions on the nanotube sidewall at the atomic level in real time at ambient temperature. Our direct observations and theoretical modelling demonstrate that the nanoprotrusions are formed in three stages: (i) metal-assisted d...

2011-01-01

221

Measurement of fission cross sections for nuclear transmutation on Am-241, Am-242m and Am-243 using lead slowing-down spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Making use of a lead slowing-down spectrometer coupled to a 46 MeV electron linear accelerator and a back-to-back type double fission chamber, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40 % full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, for which the evaluated and the experimental data were broadened by the energy resolution function of the spectrometer. (author)

1997-12-31

222

Measurement of fission cross sections for Am-241, Am-242m and Am-243 with linac-driven lead slowing-down spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Making use of a back-to-back type double fission chamber and a lead slowing-down spectrometer driven by a 46 MeV electron linear accelerator, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40 % full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, whose evaluated and measured data were broadened by the energy resolution function of the spectrometer.

1998-08-01

223

Measurement of fission cross sections for Am-241, Am-242m and Am-243 with linac-driven lead slowing-down spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Making use of a back-to-back type double fission chamber and a lead slowing-down spectrometer driven by a 46 MeV electron linear accelerator, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40% full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, whose evaluated and measured data were broadened by the energy resolution function of the spectrometer. (author)

1999-02-01

224

Depth dependence of {l_brace}311{r_brace} defect dissolution  

Energy Technology Data Exchange (ETDEWEB)

A deep band of {l_brace}311{r_brace} defects was created 520 nm below the silicon surface with a 350 keV Si implant followed by a cluster-forming rapid thermal anneal (800 C, 1000 s). Chemical etching was used to vary the depth to the surface of the {l_brace}311{r_brace}-defect band. Afterwards, the defect dissolution was investigated at 750 C for different times. Varying the depth in this fashion assures that only the depth and no other feature of the cluster distribution is changed. The {l_brace}311{r_brace} defects were analyzed by plan-view, transmission electron microscopy. We show that the dissolution time of the {l_brace}311{r_brace}-defect band varies linearly with depth, confirming that surface recombination controls the dissolution and is consistent with analogous observations of transient enhanced diffusion.

2001-09-03

225

Depth dependence of #left brace#311#right brace# defect dissolution  

International Nuclear Information System (INIS)

A deep band of #left brace#311#right brace# defects was created 520 nm below the silicon surface with a 350 keV Si implant followed by a cluster-forming rapid thermal anneal (800 C, 1000 s). Chemical etching was used to vary the depth to the surface of the #left brace#311#right brace#-defect band. Afterwards, the defect dissolution was investigated at 750 C for different times. Varying the depth in this fashion assures that only the depth and no other feature of the cluster distribution is changed. The #left brace#311#right brace# defects were analyzed by plan-view, transmission electron microscopy. We show that the dissolution time of the #left brace#311#right brace#-defect band varies linearly with depth, confirming that surface recombination controls the dissolution and is consistent with analogous observations of transient enhanced diffusion.

2001-09-03

226

Collisions between H"+ and H_2 at kilo-electron-volt energies: Absolute differential cross sections for small-angle direct, single-, and double-charge-transfer scattering  

International Nuclear Information System (INIS)

Measurements of absolute differential cross sections for H"+-H_2 direct, single-, and double-charge-transfer scattering at 0.5, 1.5, and 5.0 keV are reported at laboratory scattering angles less than 1 degree with an angular resolution of approximately 0.02 degree. The cross sections exhibit deep interference oscillations in single-charge-transfer scattering, but no such oscillations are present in direct and double-charge-transfer scattering. Theoretical cross sections derived using the diatoms-in-molecules method to describe the molecular states in a semiclassical molecular-orbital three-state close-coupling model within a semiclassical framework agree satisfactorily with the experimental results.

227

Channeling studies of radiation damage in metal-silicides  

Science.gov (United States)

Channeling effect measurements have been employed to investigate radiation damage produced by 100-keV Ar ions in preferred oriented polycrystalline metal-silicide layers, such as Pd/sub 2/Si and NiSi/sub 2/ layers formed on single-crystalline Si. For room-temperature implantation, an amount of the damage in Pd/sub 2/Si layers was found to saturate at doses between 3 x 10/sup 14/ and 1 x 10/sup 17/ ions/cm/sup 2/, where the minimum aligned yield of 1.5-MeV He ions was nearly 40% of the random one. On the contrary, it was observed that the NiSi/sub 2/ layers became amorphous at doses higher than 3 x 10/sup 15/ ions/cm/sup 2/. These results were confirmed by the reflection electron diffraction analyses.

1978-01-01

228

Channeling studies of radiation damage in metal-silicides  

International Nuclear Information System (INIS)

Channeling effect measurements have been employed to investigate radiation damage produced by 100-keV Ar ions in preferred oriented polycrystalline metal-silicide layers, such as Pd_2Si and NiSi_2 layers formed on single-crystalline Si. For room-temperature implantation, an amount of the damage in Pd_2Si layers was found to saturate at doses between 3 x 10"1"4 and 1 x 10"1"7 ions/cm"2, where the minimum aligned yield of 1.5-MeV He ions was nearly 40% of the random one. On the contrary, it was observed that the NiSi_2 layers became amorphous at doses higher than 3 x 10"1"5 ions/cm"2. These results were confirmed by the reflection electron diffraction analyses.

229

The validity of the density scaling method in primary electron transport for photon and electron beams  

International Nuclear Information System (INIS)

In the convolution/superposition method of photon beam dose calculations, inhomogeneities are usually handled by using some form of scaling involving the relative electron densities of the inhomogeneities. In this paper the accuracy of density scaling as applied to primary electrons generated in photon interactions is examined. Monte Carlo calculations are compared with density scaling calculations for air and cork slab inhomogeneities. For individual primary photon kernels as well as for photon interactions restricted to a thin layer, the results can differ significantly, by up to 50%, between the two calculations. However, for realistic photon beams where interactions occur throughout the whole irradiated volume, the discrepancies are much less severe. The discrepancies for the kernel calculation are attributed to the scattering characteristics of the electrons and the consequent oversimplified ...

230

Valence-electron configuration of Ti and Ni in Ti{sub x}Ni{sub 1-x} alloys from K{beta}-to-K{alpha} X-ray intensity ratio studies  

Energy Technology Data Exchange (ETDEWEB)

K{beta}-to-K{alpha} X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of Ti{sub x}Ni{sub 1-x} (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi {sup 109}Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured K{beta}-to-K{alpha} X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d ...

2010-06-15

231

Observations of plasma wave turbulence generated around large ionospheric spacecraft: Effects of motionally induced EMF and of electron beam emission  

International Nuclear Information System (INIS)

The authors report on observations of plasma wave turbulence generated during electron beam injections, spacecraft potential variations, and neutral gas emissions of the CHARGE 2 sounding rocket experiment. The payload was flown in a mother/daughter configuration, with the two sub-payloads electrically connected by an insulated, conducting tether. While tethered, the two platforms were separated, drifting apart in a direction perpendicular to both the magnetic field and to the spacecraft velocity, reaching a maximum distance of 426 m at the end of the flight. The mother carried a high-voltage (HV) system (0-460 V), biasing the mother negative relative to the daughter. The operation of the HV bias system simulated the motional emf induced in larger orbiting space structures like the Tethered Satellite System 1 (TSS 1) space shuttle mission scheduled for the spring of 1992. In addition, the mother carried an electron beam accelerator (1 ...

232

Free electron laser (FEL) annealing of diamond  

International Nuclear Information System (INIS)

Free Electron Laser (FEL) with wide wavelength tunability has been developed and used for various applications. We report the structural-changes in P-ion-implanted diamond when we can achieve resonant excitation of the vibrations of specific bonds in the lattice of target (P-C) by using FEL. The change of property was analyzed by SIMS and Raman spectroscopy. After 5.8 #mu#m-FEL irradiation, we observed the crystallization of amorphous structure which was induced by P-ion-implantation. These results indicated the FEL annealing of diamond at room temperature. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

1998-09-02

233

Electron beam therapy in carcinoma of the buccal mucosa  

Energy Technology Data Exchange (ETDEWEB)

Electron beam therapy has often been used for radiation therapy of carcinomas of the buccal mucosa, though side effects, including stomatitis and dermatitis, are known to exist. We experimented using the additional back scatter and transit with the phantom under a lead plate within the irradiation field, in order to better focus the dose on the target volume moreover, we fabricated a mouthpiece fitted with a lead plate shaped to the target volume, and with respect to the influence of the mouthpiece on stomatitis and dermatitis, obtained good clinical results. (author).

1990-10-01

234

Electron beam therapy in carcinoma of the buccal mucosa  

International Nuclear Information System (INIS)

Electron beam therapy has often been used for radiation therapy of carcinomas of the buccal mucosa, though side effects, including stomatitis and dermatitis, are known to exist. We experimented using the additional back scatter and transit with the phantom under a lead plate within the irradiation field, in order to better focus the dose on the target volume moreover, we fabricated a mouthpiece fitted with a lead plate shaped to the target volume, and with respect to the influence of the mouthpiece on stomatitis and dermatitis, obtained good clinical results. (author).

235

Breast carcinoma en cuirasse; Pathophysiology and rotational subtotal skin electron beam therapy (SSEBT), a new technique  

Energy Technology Data Exchange (ETDEWEB)

Carcinoma en cuirasse of the breast, which invades the skin via lymphatics and may encase the entire thorax and abdomen, is poorly controlled by surgery, chemotherapy, or conventional irradiation. Palliation of patients with breast carcinoma en cuirasse is a difficult clinical problem which must be effectively managed over extended periods due to the indolent nature of this disease. The management of three cases is reported, and the new technique of rotational subtotal skin electron-beam therapy (SSEBT) is presented. (author).

1989-04-01

236

Effects of. gamma. -irradiation on isolated rat liver mitochondria  

Energy Technology Data Exchange (ETDEWEB)

Gamma-irradiation of isolated rat liver mitochondria with up to 475 Gy leading to hydrated electrons (G = 1.9, corrected for reaction with solutes), 30 Gy leading to carbohydrate radicals, (G = 5.6), 100 Gy leading to superoxide radicals (G = 6.2), and 130 Gy leading to formate radicals (G = 6.2) showed no effects on the rate of oxygen uptake in various respiratory states, the respiratory control ratio, or the adenosine diphosphate to atomic oxygen ratio. Typical values were 0.020-0.100 nmol O/sub 2/ s/sup -1/ mg protein/sup -1/ for State 1 respiration, 0.25-0.33 nmol O/sub 2/ s/sup -1/ mg protein/sup -1/ for State 4 respiration and 0.65-1.10 nmol O/sub 2/ s/sup -1/ mg protein/sup -1/ for State 3 respiration. Typical respiratory control ratios ranged from 2.0-3.5 for succinate and 4.0-6.5 for a 1:1 glutamate: malate substrate mixture. Adenosine diphosphate to atomic oxygen ratios with succinate as substrate varied from 1.6 to 1.9. In situ and ...

1987-01-01

237

Nuclear radiation detectors on II-VI compounds  

International Nuclear Information System (INIS)

Nuclear radiation detectors in integral execution were produced by successive epitaxial growth from vapor phase of Zn Te and Cd Se thin layers onto scintillating Zn Se (Te) crystals. The irradiation of combined Zn Se (Te) - Zn Te - Cd Se detectors by Cu_K_a X-rays leads to the appearance of photoreceiver e.m.f., which tends to saturation with the increase of X-ray radiation dose reaching the value of 0.34-0.40 V at 200 R/min. The short circuit current dependence of irradiation dose power is linear. The matching factor for detectors with Zn Te-Cd Se photoreceivers with different doping levels is 0.68-0.92. The absolute monochromatic sensitivity is 0.32-0.35 m A/m W at a quantum efficiency 0.58-0.61 and a time constant 2 x 10"-"4 s. The calculated dose sensitivity for Zn Se(Te)-Zn Te-Cd Se combined detectors at the irradiation with X-rays having effective energy 8.86 keV gives the value 3.9 x 10"-"7 ...

1993-10-13

238

The surface modification of tooth dentine with a Free Electron Laser (FEL)  

International Nuclear Information System (INIS)

Free Electron Laser (FEL) with the wide wavelength tunability has been developed and used for various applications. The FEL gives high efficiency for the photo-induced ablation when the laser is tuned to an absorption maximum of the target. The FEL was tuned to 9.4 #mu#m, which is an absorption maximum of phosphoric acid ion, a known major component of dentine. The FEL pulse length was several ps. The average output power was varied from 5 to 20 mW by filters. The change of irradiated dentine surface was analyzed by mass spectroscopy and Energy Dispersive X-ray (EDX) spectroscopy. Positive ions which correspond to Na"+, CO_3"+ and many phosphoric acid ions were measured. It was found that atomic ratio of P/Ca had reduced from 0.65-0.60. The atomic ratio of P/Ca, however had not changed with irradiation by Er:YAG laser (2.9 #mu#m), or CO_2 laser (10.6 #mu#m). These results indicate the selective ablation of phosphoric acid ...

1998-09-02

239

The Mechanical Properties of Alumina Films Formed by Plasma Deposition and by Ion Irradiation of Sapphire  

Energy Technology Data Exchange (ETDEWEB)

This paper examines the correlation between mechanical properties and the density, phase, and hydrogen content of deposited alumina layers, and compares them to those of sapphire and amorphous alumina synthesized through ion-beam irradiation of sapphire. Alumina films were deposited using electron beam evaporation of aluminum and co-bombardment with O{sub 2}{sup +} ions (30-230 eV) from an electron cyclotron resonance (ECR) plasma. The H content and phase were controlled by varying the deposition temperature and the ion energy. Sapphire was amorphized at 84 K by irradiation with Al and O ions (in stoichiometric ratio) to a defect level of 4 dpa in order to form an amorphous layer 370 nm thick. Nanoindentation was performed to determine the elastic modulus, yield strength and hardness of all materials. Sapphire and amorphized sapphire have a higher density and exhibit superior mechanical properties in ...

1999-07-16

240

Magnetic imaging of ion-irradiation patterned Co/Pt multilayers using complementary electron and photon probes  

Energy Technology Data Exchange (ETDEWEB)

The three-dimensional magnetic structure and reversal mechanism of patterned Co/Pt multilayers, were imaged using complementary Lorentz transmission electron microscopy (LTEM) (in-plane component) and magnetic transmission x-ray microscopy (M-TXM) (perpendicular magnetization). The Co/Pt films with perpendicular anisotropy were patterned by ion irradiation through a stencil mask to produce in-plane magnetization in the irradiated regions. The boundaries of the patterns, defined by the transition from out-of-plane to in-plane magnetization, were found to be determined by the stencil mask, whilst the scale of the magnetic reversal by the physical microstructure. The nucleation fields were substantially reduced to 50 Oe for the in-plane regions and 1 kOe for the perpendicular regions, comparing to 4.5 kOe for the as-grown film. The perpendicular reversals were found to always originate at the pattern boundaries.

2001-04-01

241

Gelatin ablation wavelength dependency in the range of 5.6-6.7 #mu#m using a mid-infrared Free Electron Laser  

International Nuclear Information System (INIS)

Efficient and precise ablation of soft tissue is needed for non-invasive dermatological and corneal surgeries. Previous research has revealed that smooth and efficient cutting of certain soft tissues and gelatin is possible using a Free Electron Laser (FEL) with a wavelength of #lambda#=6.45 #mu#m, tuned to the amide-II band of protein. Gelatin ablation experiments have been carried out using a mid-infrared FEL within the waveband #lambda#=5.6-6.7 #mu#m by changing the primary absorbers such as water (#lambda#=6.1 #mu#m) and protein (#lambda#=6.45 #mu#m). The gelatin with 80 wt% water was efficiently ablated by FEL irradiation with the waveband #lambda#=#approx#5.95-6.19 #mu#m. On the other hand, using irradiation within #lambda#=#approx#6.4-6.6 #mu#m, many small bubbles were observed in the irradiated volume, and the gelatin was not ablated but significantly melted. Thus, it was found that the most ...

2003-07-11

242

Radiation treatment of crude drugs. Development of suitable methods of detection. Strahlenbehandlung von Arzneidrogen. Entwicklung geeigneter Nachweismethoden  

Energy Technology Data Exchange (ETDEWEB)

It may be necessary to reduce microbiological contamination of crude drugs (medicinal plants or their parts like roots, leaves, flowers). This can be done by treating the drugs with ionizing radiation. Meethods for detection of such an irradiation were developed. It could be pointed out that measurements of luminescence, viscosity and electron spin resonance were suitable for specific drugs, but not for all drugs. (orig.).

1992-09-01

243

Radial distribution of bonded fission gas in mixed carbide fuel pins  

International Nuclear Information System (INIS)

The fission gas xenon bonded in bubbles, in pore, and in the lattice of mixed carbide fuels is measured by electron-probe microanalysis. Radial xenon distribution and release curves are determined and are calibrated by gas chromatography of the bonded fission gas and by burnup analysis in the respective pin sections of the irradiation experiments FR2 6A and 6C, Mol 11/K 2, and DFR 330/1. The results are correlated to the microstructure of the fuel, bonding medium, temperature, and burnup. (Auth.).

1979-01-01

244

Investigation of radiation defects in solids using the EXAFS method  

International Nuclear Information System (INIS)

The exafs method is proposed as a more informative, universal one to investigate the radiation defects in solids. The successful results as obtained by the author using the synchrotron radiation source are reported for the first time. The measurements were carried out in GaAsP crystals irradiated with 50 MeV electrons.

1978-02-15

245

Accelerator aspects of {gamma}-{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

There are several on-going projects of e{sup +}e{sup -} colliders. If they are constructed, we can convert them into photon-photon ({gamma}-{gamma}) colliders by converting electron beams into {gamma} beams, irradiating laser beams just before the interaction point. In this report we discuss the technical issues on the accelerator.

2000-11-21

246

Measurements and elimination of Cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry  

International Nuclear Information System (INIS)

In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component of a fiber-optic ...

2007-08-21

247

Construction, testing of the 1 MW, 130-260 GHz Fusion-FEM  

Energy Technology Data Exchange (ETDEWEB)

During the previous 9 months the major part of the Fusion-FEM has been constructed. The 2 MV Insulated Core Transformer, the electron gun, the accelerator, the focusing lenses and the undulator have been tested on-site. In the present - temporary - set-up, the electron beam line consists of a 12 A, 80 keV thermionic electron gun, a 2 MeV dc accelerator, beam transport optics, the undulator and a collector. The gun is mounted in the high voltage terminal, which is now at -2 MV, and the undulator and mm-wave system am at ground potential outside the SF{sub 6}-filled pressure tank. This so-called inverse set-up allows easy access to the larger part of the beam line, the undulator and the mm-wave system, which is important in the conditioning phase. The decelerator and depressed collector am not yet installed. The design of the electron beam line has been optimised using the GPS ...

1995-12-31

248

Physico Mechanical Properties of Irradiated Waste Rubber Cement Mortar  

International Nuclear Information System (INIS)

In the present study a partial replacement of aggregate with two different ratios of waste rubber (5%, 10%) with the addition of a constant ratio of rice husk ash (RHA), 5% was carried out. The hardened cement mortar used the optimum water of consistency. The specimens were molded into 1 inch cubic moulds .The specimens were first cured for 24 hours, at 100% relative humidity and then cured under tap water for 3, 7 and 28 days followed by irradiation at different doses of gamma irradiation namely 5 and 10 kGy. The physico-chemical and mechanical properties such as compressive strength, total porosity and bulk density were studied for the three types of specimens. The results showed that the values of the compressive strength, bulk density and chemically combined water of the blended cement mortar paste (OPC-RHA) increase ,while blended cement mortar paste with 5% RHA and 5, 10% waste rubber decrease. The results were confirmed by scanning ...

249

ESR dosimetry of irradiated chicken legs and chicken eggs  

Energy Technology Data Exchange (ETDEWEB)

Ionising radiation induces stable free radicals in chicken bones and in the shell of chicken eggs which can be detected, by the electrons spin resonance (ESR) technique, well beyond the shelf-life of the food and can be used for dosimetry. The method usually adopted to evaluate ``a posteriori`` the dose given during the ionising radiation treatment of food, is the dose additive method. To assess the dose, the ESR signal amplitude of the irradiated food (bone or egg shell in the present case) is measured and then the dose-effect relationship is obtained by re-irradiating the sample with some additive doses (usually of 1 kGy). The dose-effect curve is back-extrapolated and the initial given dose determined. At the Istituto Superiore di Sanita (ISS), Rome, Italy, a research programme was approved two years ago aimed to, (1) study new methodological approaches for ESR dose assessment, and (2) analyse the factors which may ...

1996-12-31

250

Absolute detection efficiency of radiation detecting system for gamma-ray from sources with high activity  

Energy Technology Data Exchange (ETDEWEB)

In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the {sup 137}Cs-source with 10.4 GBq and {sup 60}Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form {sup 137} Cs 1173.23 and 1332.51 keV{sup 60} Co sources, and 14 peaks of {sup 134}Cs and {sup 154}Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show that the detection efficiency of gamma ...

2003-10-01

251

Surface excitation correction of the inelastic mean free path in selected conducting polymers  

International Nuclear Information System (INIS)

In earlier works, the inelastic mean free path (IMFP) of electrons was determined by elastic peak electron spectroscopy (EPES) using Ni and Ag reference standard samples, but fully neglecting surface excitation. Surface excitation that is characterized by the surface excitation parameter (SEP), and may affect considerably the elastic peak for the sample and the reference material. The SEP parameters of selected conducting polymers (polythiophenes, polyaniline and polyethylene) were determined by EPES using Si and Ge reference samples. Experiments were made with a hemispherical analyzer of energy resolution 100-200 meV in the E = 0.2-2.0 keV energy range. The composition of the sample surfaces was determined by in situ XPS, their surface roughness by AFM. The experimental SEP parameter data of eight polymer samples were determined by our new procedure, using the formulae of Chen and Werner et al. in the E = 0.2-2.0 ...

2006-05-15

252

Steering of high energy negative ion beam and design of beam focusing/deflection compensation for JT-60U large negative ion source  

Energy Technology Data Exchange (ETDEWEB)

A large negative ion source for JT-60U produces high current ion beam from a wide extraction area of 45 cm x 110 cm. On the other hand, a cross-sectional area of the negative ion based neutral beam (NNB) injection port on JT-60U is narrow, about 50 cm x 60 cm. In order to inject the neutral beam at a high geometric efficiency, i.e. to suppress beam loss in the beamline, it is necessary to steer the beam for both compensation of undesirable beam deflection in extractor and focusing of the beam. For the JT-60U, two methods are provided for the required beam steering. Among them the results of beam steering experiment by aperture displacement and the design study are summarized in the present report. The experiment was carried out with 400 keV negative ion source, which has the three stage accelerator of similar structure as the JT-60U ion source, at Negative Ion Acceleration Test Stand (NIAS). High energy negative ion beams of the same perveance as that of 500 ...

2000-03-01

253

Soft X-ray holography of FIB nanostructured Co/Pt multilayers  

International Nuclear Information System (INIS)

Focused Ion Beam (FIB) milling is a powerful tool to produce ordered magnetic nanostructures. However, it is impossible to produce out-of-plane magnetized nanoscale structures from multilayer films by direct FIB writing. Co/Pt multilayers exhibit an out-of-plane easy axis due to strong perpendicular interface anisotropy. The interface contribution is known to be very sensitive to high energy ion irradiation. In case of 30 keV Ga ions it needs less than one ion per 100 surface atoms to destroy the perpendicular interface anisotropy. We demonstrate how this problem can be overcome by milling a Co/Pt multilayer, which has been deposited on a SiN membrane, from the rear side, through the SiN. The effect of the ions is determined as a function of applied dose utilizing the domain structure imaged by soft X-ray holography. When the magnetic material is removed we find only a very narrow range of destruction around the holes in contrast to the ...

2009-03-22

254

Measurement of "1"0"1Tc Half-Life  

International Nuclear Information System (INIS)

75 mg (NH_4)_6Mo_7O_24 #centre dot# 4H_2O solution was irradiated for 20 min in miniature neutron source reactor (MNSR) and cooled for 12 min. In the conditions of 0.8 mol/L HNO_3, phase ratio 1:1, the solution of "1"0"1Tc sample was extracted twice with #alpha#-benzoin oxime/ethyl acetate phase to remove "1"0"1Mo and a radiochemically pure and carrier-free "1"0"1Tc product was obtained. The half-life of "1"0"1Tc was accurately measured with a HPGe #gamma#-detector by following 306.8 keV #gamma#-ray about 150 min, and processed the data by three methods, R-value method, iterative method and translation method. Five parallel measurments gave a half-life (14.02 #+-# 0.01) min (n=5) for "1"0"1Tc. (authors)

2009-11-01

255

CoSi_2 nanostructures by writing FIB ion beam synthesis  

International Nuclear Information System (INIS)

A mass separated focused ion beam (FIB) is a very useful tool to fabricate nanostructures by writing implantation within an ion beam synthesis process. In these investigations the IMSA-OrsayPhysics FIB, equipped with a Co_3_6Nd_6_4 alloy liquid metal ion source, was applied. Si(100) and (111) wafers were implanted with 60 keV Co"+"+ ions in the dose range of 2 . 10"1"6 to 2 . 10"1"7 cm"-"2. Implantation parameters were investigated, like pixel dwell time, relaxation time (time between two cycles), dose rate as well as the pixel overlapping factor. The subsequent annealing was done in a two step process, namely 600 deg. C for 60 min and 1000 deg. C for 30 min in a N_2 ambient. The results obtained by SEM investigations in terms of continuous nanowire structures following the direction and interrupted CoSi_2 pattern in the direction show a clear dependence on the time scale as well as the scanning mode of the irradiation. Structure sizes as ...

2006-07-01

256

The magnetoresonance operation of microwiggler on the piezoelectrics with a strong magnetic guide field  

Energy Technology Data Exchange (ETDEWEB)

We proposed that a new type of the electrostatic microwiggler with a wiggler period (0.1 mm {le}1{sub w}{le}1 mm) and the wiggler field strength (E{sub w}{le} 100 kV/m) can be produced on the surface of a PZT when a high power and high frequency ultrasonic wave travels through a PZT bar. Numerical simulations in the linear and nonlinear gain regime show that a weak microwiggler (E{sub w}100 kV/m,{lambda}{sub w}{approx}100 periods), operating in magnetoresonance with a strong guide field (B{sub o}{approx} 3.6T), can generate a millimeter and submillimeter radiations with medium electronic efficiency of few percents. It is shown that the maximum output power of the compact FEL using the wiggler system generated on the surface of the piezoelectric material may be upto a few Watts with a relatively low energy and low current electron beam (Ew {approx}100 keV and I{sub b}1 mA).

1995-12-31

257

Pulse Rise Time Characterization of a High Pressure Xenon Gamma Detector for use in Resolution Enhancement  

CERN Document Server

High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics was used to characterize the pulse rise ...

2000-01-01

258

Performance of Alcator C-Mod core Thomson scattering system  

Energy Technology Data Exchange (ETDEWEB)

Design of the Alcator C-Mod Thomson scattering (TS) diagnostic is discussed and the results of the measurements are presented. The TS system has six spatial channels with observation volumes evenly distributed between the midplane and the edge of the plasma. Each channel is capable of measuring the electron density in the range N{sub e}=5{times}10{sup 19}{endash}5{times}10{sup 21} m{sup {minus}3} and temperature from T{sub e}=200 eV to 10 keV. A 30 Hz, 1.5 J per pulse Nd-YAG laser is employed allowing the measurements of evolution of T{sub e} and N{sub e} profiles during plasma shot. A laser beam position control and feedback system provides for the beam alignment stability and reliable electron density measurements. Examples of the core density and temperature profiles measured at different stages of the plasma evolution are discussed. {copyright} {ital 1999 American Institute of Physics.}

1999-01-01

259

Free electron laser facilities employing a 150-MeV linac injector for Saga synchrotron light source  

International Nuclear Information System (INIS)

Free electron laser (FEL) facilities as the FELI FEL Facility are proposed, for which a 150-MeV linac type injector for a Saga synchrotron light source (SLS) is employed in FEL mode. The linac has two operating modes; short macropulse mode a 1 #mu#s at 150 MeV for injection to a 1 - 1.3-GeV third generation type storage ring and long macropulse mode of 12 #mu#s at 100 MeV for four FEL Facilities. The macropulse beam consists of a train of several ps, 0.6 nC microbunches (peak current 100 A) repeating at 89.25 MHz. We are aiming to supply high power level photon beams covering an attractive wavelength range from 0.05 nm (25 keV) to 200 #mu#m (0.006 eV) for scientific researches, bio-medical and industrial applications, using the Saga third generation type SLS with a superconducting wiggler and the proposed four FEL Facilities. (author)

1999-12-01

260

Gamma rays produced by inverse Compton scattering in the super-ACO storage ring free electron laser  

International Nuclear Information System (INIS)

The inverse Compton scattering between positron bunches and the Free Electron Laser (FEL) of the SuperAco storage ring generates a collimated and tunable gamma-ray beam. The use of the FEL instead of a conventional laser, automatically provides the transverse alignment and synchronisation of the electron and optical beams. The Super-ACO FEL is operated in the 300-430 nm range at 800 MeV with a high repetition rate (8 MHz) and an average transmitted power of 300 mW at 350 nm. High energy gamma rays of 35 MeV are produced with a rate of 1.5 10 7 photons/second and good monocromaticity (about 10%). Applications of the SuperAco FEL installation for diamond irradiation and biological studies are envisaged. (author)

2000-06-05

261

Advanced oxidation process based on ozone/electron beam irradiation for treating groundwater  

International Nuclear Information System (INIS)

There are several methods of generating OH free radicals from ozone and/or hydrogen peroxide and ultraviolet light. They all have in common that the OH free radicals originate in one single source only whereas in the combination of ozone with ionizing radiation two simultaneous working sources for the OH free radicals exist. The resulting higher OH free radical concentration makes this process especially apt for the remediation of low level contaminated groundwater as for example trichloroethylene (TCE) contamination in the sub-ppm range. A cost comparison between O_3/UV and O_3/electron beam for remediation of a groundwater contaminated with 100 ppb TCE indicated that for a throughput of about 5 million gallons/day the O_3/electron beam process is more cost-effective. (authors).

262

Electron beam intraoral cone therapy in carcinoma of tongue. Report of eight cases and review of the literature  

Energy Technology Data Exchange (ETDEWEB)

The clinical results of electron beam therapy using intraoral cone in 8 cases of primary and recurrence carcinoma of tongue (T1 and smaller T2) were reported. The primary and recurrence cases were 5 and 3, respectively. In the 5 cases, a total dose of 10-30 Gy external radiation therapy were combined prior to electron beam therapy. The total dose of electron beam therapy varied from 40 to 60 Gy. In all cases, tumor showed good response and disappeared clinically. Radiation stomatitis, pain of the tongue with masticatory disturbance due to tenderness were complicated in all cases. These complications gradually disappeared 2 to 6 months after treatment. However, loss of body weight and bone exposure were not recognized in any case. Intraoral-cone electron beam therapy is thought to be available and has less complications comparing interstitial irradiation therapy from the review of ...

1989-06-01

263

Water Repellency Microstructure Oligomer Formulation Cured with Electron Beam  

International Nuclear Information System (INIS)

Water repellency en the microstructure super-hydrophobic cured surface is important for research and industrial purposes. This microstructure film can be cured on polyethylene terephthalate PET surface by electron beam (EB) at different irradiation doses 10-100 kGy. The microstructure formulation composed from hydrophobic acrylate oligomer (EB 244) and monomer (SR 440). The irradiation induced cross linking of the prepared microstructure was proved by FTIR spectroscopy and the adhesion force by abrasion test. Some factors affecting the adhesion force of the prepared microstructure film such as oligomer/monomer composition ratio and the thickness of the microstructure cured film were studied. The contact angles (8) were measured on cured surfaces before and after adding the super hydrophobic nanoparticles (Zonyl 9361). The super-hydrophobic cured surface showed the self-cleaning property. The volume of water droplet affected ...

264

Photo-induced transformation of close Frenkel pairs in strontium fluoride  

International Nuclear Information System (INIS)

Laser-induced change is studied of the optical absorption and luminescence due to F-H pairs generated by an electron pulse in SrF_2. It is found that laser irradiation near 2.34 eV at a delay of 26 #mu#s after an electron pulse by which F-H pairs are generated reduces the component I of the pairs that has a decay time of 59 #mu#s and optical absorption bands at 2.34 and 4.13 eV and enhances the component II that has a decay time of 7.7 ms and has optical absorption bands at 2.7 and 3.35 eV. Laser irradiation near 2.7 eV at a delay of 4 ms after the electron pulse is found to induce the reverse reaction. Studies of dichroism of the laser-induced reduction and enhancement of the optical absorption bands and the luminescence reveal that the direction of the #SIGMA#-#SIGMA# transition of the F_2"- molecular ion is converted by the transformation from I to II and vice versa. It is ...

265

Minority-carrier lifetime damage coefficient of irradiated InP  

Energy Technology Data Exchange (ETDEWEB)

Minority-carrier lifetime damage coefficients for 1 MeV electron, 3 MeV proton, and 6 MeV alpha particle irradiation of n-type (4.5{times}10{sup 15} and 1.3{times}10{sup 17}cm{sup {minus}3}) and p-type (2.5{times}10{sup 17}cm{sup {minus}3}) InP have been measured using time-resolved photoluminescence. These values are relatively insensitive to carrier type and show a slight increase with increasing carrier concentration. Evidence of comparable electron and hole capture lifetimes is found for the dominant recombination defect. The effect of 3 MeV proton and 6 MeV alpha particles relative to 1 MeV electrons is an increase in the lifetime damage coefficient by factors of about 10{sup 4} and 10{sup 5}, respectively. {copyright} {ital 1997 American Institute of Physics.}

1997-09-01

266

K#beta#-to-K#alpha# x-ray intensity ratio studies of the valence electronic structure of Fe and Ni in Fe_xNi_1_-_x alloys  

International Nuclear Information System (INIS)

K#beta#-to-K#alpha# x-ray intensity ratios of Fe and Ni in pure metals and in Fe_xNi_1_-_x alloys (x=0.20, 0.50, 0.58) exhibiting similar crystalline structure have been measured following excitation by 59.54 keV #gamma# rays from a 200 mCi "2"4"1Am point source to understand why the properties of the Fe_xNi_1_-_x (x=0.2) alloy are distinct from other alloy compositions. The valence electronic structure of Fe and Ni in the samples has been evaluated by comparing the measured K#beta#-to-K#alpha# intensity ratios with the results of multiconfiguration Dirac-Fock calculations. Significant changes in the 3d electron population (with respect to the pure metal) are observed for Fe and Ni for certain alloy compositions. These changes can be explained by assuming rearrangement of electrons between 3d and (4s,4p) band states of the individual metal atoms. It has been found that the valence ...

2001-02-15

267

Observation of 77 K staircase I-V characteristics in 2DEG's irradiated by a focused ion beam  

International Nuclear Information System (INIS)

Staircase current-voltage (I-V) characteristics, observed at 77 K in narrow 2DEG channels irradiated by a single line scan of a focused ion beam (FIB), is reported in detail. These staircases are interpreted as evidence of single electron tunneling through a naturally occurring specific Coulomb island in the random potential fluctuations created by FIB damage. Clear comparison is made between the I-V's taken from wide channels and those from narrow channels. Based on orthodox calculations of the I-V characteristics, it is shown that highly asymmetric tunnel junctions are needed to explain our data. This is consistent with the random nature of the potential landscape in the FIB damaged region. (author).

268

Mechanism of the accumulation effect in laser damage to polymers: appearance of microdamage due to an ionization absorption wave  

Energy Technology Data Exchange (ETDEWEB)

An investigation was made of the accumulation of laser damage to transparent polymers irradiated with nanosecond pulses from neodymium and ruby lasers. The damage was investigated by the method of scattering and luminescence in the visible and near ultraviolet parts of the spectrum. It was established that there were two stages in laser damage by repeated irradiation with pulses of intensity below the single-shot damage threshold. An absorbing defect evolved during the first stage in such a way as to create a thermal instability in the surrounding matrix. During the second stage this thermal instability caused spatial growth of laser damage because of propagation of an ionization-inducing absorption wave with a front traveling at the rate governed by the electron component of the thermal conductivity.

1984-04-01

269

Measurement of skin dose in primary irradiation of maxillary sinus carcinoma  

Energy Technology Data Exchange (ETDEWEB)

Subcutaneous involvement frequently occurs in maxillary sinus carcinoma. Radical resection does not include removal of the skin at risk. In standard postoperative wedge-pair treatment plans, the surface dose is dependent upon beam weighting, beam energy, and patient contour. Thermoluminescent dosimetry (TLD) measurements were performed to evaluate the surface dose of patients undergoing postoperative irradiation of maxillary sinus carcinoma following primary resection. When 60 Gy was delivered to isocenter with a 45 degrees wedge pair and 6 MV photons with 1 cm bolus, the subcutaneous tissues at risk received {approximately} 30 Gy. Based upon presented TLD measurements, supplemental electron beam therapy to the subcutaneous tissues if primarily involved should be considered.

1991-03-01

270

Irradiation effects on the electrochemistry and corrosion resistance of stainless steel  

International Nuclear Information System (INIS)

Nickel ion radiation at 500 C was shown to have a strong effect on the surface electrochemistry and intergranular corrosion (IGC) of stainless steel (SS). Measured current densities in a 1 N sulfuric acid solution at room temperature were increased at active-passive, passive, and transpassive potentials. Radiation effects on the current decay behavior and susecptibility to IGC were similar for a fine-grained (FG) S alloy and for a very large-grained (LG) SS. Radiation-induced segregation (RIS) at the surface was believed to promote higher currents at short times, whereas segregation at grain boundaries was responsible for IG attack. Analytical electron microscopy (AEM) measurements revealed chromium and iron depletion plus Ni and silicon enrichment at grain boundaries in irradiated specimens. Si enhanced dissolution at transpassive potentials, whereas Cr depletion did the same at active-passive and passive potentials.

1995-01-01

271

Enhanced inactivation of bacteria by metal-oxide nanoparticles combined with visible light irradiation  

British Library Electronic Table of Contents (United Kingdom)

AbstractBackground In recent years nano-metaloxides which easily penetrate into the cells with special interest due to their higher chemical reactivity as compared to that of similar materials in the bulk form. Of particular interest are nano-TiO2 and ZnO, which have been widely used for their bactericidal and anticancerous properties. Purpose The aim of the present study was to examine the bactericidal properties of nano-TiO2 and ZnO combined with visible light on S. aureus and S. epidermitis, known for their high prevalence in infected wounds. Study Using the technique of electron-spin resonance (ESR) coupled with spin trapping, we examined the ability of TiO2 and ZnO nanoparticle suspensions in water to produce reactive oxygen species (ROS) with and without visible light irradiation. Th...

2011-01-01

272

Effects of stress on radiation hardening and microstructural evolution in A533B steel  

British Library Electronic Table of Contents (United Kingdom)

Bent specimens of A533B steel (0.16wt% Cu) were irradiated at 290degreeC to 1dpa with 6.4MeV Fe3+ ions. Calculated tensile stresses at the irradiated surface were set to 0, 250, 500 and 750MPa. The specimens were subjected to hardness measurements, transmission electron microscopy (TEM) observations and three-dimensional atom probe (3DAP) analysis. The radiation-induced hardening decreased with increasing stress to 500MPa which was near the yield strength. TEM and 3DAP results showed that well-defined dislocation loops and solute clusters were formed. The diameter of dislocation loops increased and the number density decreased when the stress was applied, whereas the diameter and number density of solute clusters decreased. The hardening was mainly attributed to solute cluster formation. A...

2010-01-01

273

Effect of ionizing radiation on the properties of PLA packaging materials  

International Nuclear Information System (INIS)

Poly(lactic acid) (PLA) is attractive as a substitute for classical polymer packaging material due to its biodegradability and sufficient mechanical and barrier properties. Presented research was focused on the changes of basic mechanical parameters after ionizing irradiation performed with doses in the range of 2.5-25 kGy, commonly used in radiation sterilization and preservation of foods. Two commercial available PLA packaging films were tested. The influence of radiation dose on the mechanical properties - tensile strength and elongation were determined using standardized methods. Radiation resistance of PLA is sufficient for packaging applications. The investigations of gas products of radiolysis of PLA have been made by gas chromatography after electron beam (EB) irradiations. (authors)

274

Effect of decrease of molybdenum radiation hardening at high energy proton irradiation  

International Nuclear Information System (INIS)

By method of transmission electron microscopy and measuring of microhardness the peculiarities of influence of radiation defect clusters on molybdenum radiation hardening along range path of protons with 30 MeV initial energy are studied. Decrease effect of hardening growth value and even its absence depending on irradiation dose in the range of 10-20 MeV proton energies in presence of high density of radiation defect dispersed clusters is revealed. It is shown experimentally that this effect is connected with accumulation of hydrogen up to not very high concentrations (not more than 5x10"-"4 at.%) at the expense of elastic and inelastic proton scattering. 5 refs.; 5 figs.

1990-05-22

275

Analysis on anomalous degradation in silicon solar cell designed for space use  

Energy Technology Data Exchange (ETDEWEB)

Recently, we have found the anomalous degradation of electrical performance in silicon solar cells irradiated with charged particles in a high-fluence region. This anomalous phenomenon has two typical features, which are sudden-drop-down of electrical performances in a high-fluence region and slight recovery of the short circuit current I{sub SC} just before the sudden-drop-down. These features cannot be understood by a conventional model coming from the decrease of minority-carriers life-time. We introduce this anomalous degradation of the electrical performance in Si solar cells irradiated with electrons or protons. We also report the result of simulation for the fluence dependence of the I{sub SC}, and discuss the mechanism of this anomalous phenomenon. (author)

1997-03-01

276

Swelling behavior of a simple ferritic alloy  

International Nuclear Information System (INIS)

The swelling behavior which results from simulated fusion environment irradiation of Fe-10% Cr has been characterized with transmission electron microscopy. Specimens were bombarded at 850 K with: a ''triple-beam'' of He"+, D_2"+, and 4 MeV Fe"+"+ ions to 0.3, 1, 3, 10, 30, and 100 dpa (displacement per atom); a ''dual-beam'' of He"+ and 4 MeV Fe"+"+ ions to 30 and 100 dpa; and a ''single-beam'' of 4 MeV Fe"+"+ ions to 30 dpa. The helium and hydrogen injection rates were approx. =10 appm He/dpa and approx. =40 appm D/dpa. Cavities were observed for damage levels of 3 dpa and greater. The swelling was <0.1% for damage levels <30 dpa, but at 100 dpa, there was an increase in the swelling to 2.5% for the ''triple-beam'' irradiation and 1.2% for the ''dual-beam'' irradiation. The swelling rates between 30 and 100 dpa correlate well with calculated values assuming a steady-state swelling-rate regime ...

277

Microstructural evolution of single crystalline Al{sub 2}O{sub 3} irradiated with single and triple ion beams  

Energy Technology Data Exchange (ETDEWEB)

The radiation-induced microstructural changes have been studied by cross-sectional transmission electron microscopy for single-crystal {alpha}-Al{sub 2}O{sub 3} samples irradiated with triple ion beams (0.25 MeV H{sup +}, 0.6 MeV He{sup +} and 2.4 MeV O{sup 2+}; `Triple (A)`), (0.33 MeV H{sup +}, 0.45 MeV He{sup +} and 1.3 MeV O{sup +}; `Triple (B)`) and three consecutive single ion beams (0.3 MeV H{sup +} ion followed by 0.6 MeV He{sup +} and then 0.8 MeV O{sup +} ions) at 650 C to doses in the range 0.1-8.4 dpa at the damage peak. In the specimen irradiated with Triple (A), having the same average projected range to a total peak dose of 3.7 dpa, cavities with an average diameter of 13 nm were formed between 1.2 and 1.75 {mu}m in depth causing a swelling of 0.1% at the peak, which is larger than those of the specimens irradiated with other conditions. The extent of the cavity-introduced region is some ...

1996-10-01

278

Microstructural evolution of single crystalline Al_2O_3 irradiated with single and triple ion beams  

International Nuclear Information System (INIS)

The radiation-induced microstructural changes have been studied by cross-sectional transmission electron microscopy for single-crystal #alpha#-Al_2O_3 samples irradiated with triple ion beams (0.25 MeV H"+, 0.6 MeV He"+ and 2.4 MeV O"2"+; 'Triple (A)'), (0.33 MeV H"+, 0.45 MeV He"+ and 1.3 MeV O"+; 'Triple (B)') and three consecutive single ion beams (0.3 MeV H"+ ion followed by 0.6 MeV He"+ and then 0.8 MeV O"+ ions) at 650 C to doses in the range 0.1-8.4 dpa at the damage peak. In the specimen irradiated with Triple (A), having the same average projected range to a total peak dose of 3.7 dpa, cavities with an average diameter of 13 nm were formed between 1.2 and 1.75 #mu#m in depth causing a swelling of 0.1% at the peak, which is larger than those of the specimens irradiated with other conditions. The extent of the cavity-introduced region is some 40% smaller than observed in the damage region due to ...

279

Extracranial-intracranial bypass surgery utilizing homologous arterial grafts irradiated with high voltage cathode rays. Experimental study and clinical application  

Energy Technology Data Exchange (ETDEWEB)

Homologous and heterologous arterial segments were implanted in Fisher rats subcutaneously for the purpose of examining the antibody titer of the recipients' serum after implantation by means of the immune-adherence hemagglutination method. The antibody titer after implantation both of homologous and heterologous grafts decreased to 1/8 by 2.0 million (M) rads irradiation of high voltage cathode rays. The results suggested that high voltage cathode ray irradiation was not enough for heterologous graft to suppress its tissue reaction. Homografts taken from dogs 3 or 6 hours after sacrifice were irradiated with 2.0 M rads and transplanted in canine carotid artery using the technic of end-to-end anastomosis. Angiograms 6 months after operation revealed excellent patency rate in all the grafts of 28 dogs. furthermore, findings of the grafts from 1 week to 5 years after operation on scanning and transmission ...

1982-06-01

280

Extracranial-intracranial bypass surgery utilizing homologous arterial grafts irradiated with high voltage cathode rays  

International Nuclear Information System (INIS)

Homologous and heterologous arterial segments were implanted in Fisher rats subcutaneously for the purpose of examining the antibody titer of the recipients' serum after implantation by means of the immune-adherence hemagglutination method. The antibody titer after implantation both of homologous and heterologous grafts decreased to 1/8 by 2.0 million (M) rads irradiation of high voltage cathode rays. The results suggested that high voltage cathode ray irradiation was not enough for heterologous graft to suppress its tissue reaction. Homografts taken from dogs 3 or 6 hours after sacrifice were irradiated with 2.0 M rads and transplanted in canine carotid artery using the technic of end-to-end anastomosis. Angiograms 6 months after operation revealed excellent patency rate in all the grafts of 28 dogs. furthermore, findings of the grafts from 1 week to 5 years after operation on scanning and transmission ...

1982-01-01

281

Total interaction cross sections and effective atomic numbers of some biologically important compounds containing H, C, N and O in the energy range 6.4-136 keV  

International Nuclear Information System (INIS)

The total interaction cross sections (#sigma#_t) of some sugars and amino acids and five elements: lithium, carbon, oxygen, aluminium and calcium have been measured for 6.4 keV, 13.95 keV, 14.4 keV, 17.74 keV, 24.14 keV, 30.8 keV, 35 keV, 59.54 keV, 81 keV, 122 keV and 136 keV photons in a narrow beam good geometry set up, by using high resolution detectors such as a Si-PIN diode detector and a high purity germanium detector. The #sigma#_t values have been used in a matrix method to evaluate the effective atomic numbers Z_e_f_f of the samples from their effective atomic cross sections #sigma#_a. The effective atomic cross section of a sample #sigma#_a is the total interaction cross section divided by the total number of atoms of all types in it. Further, a ...

2007-09-28

282

Comparisons of Monte Carlo calculations with absorbed dose determinations in flat materials using high-current, energetic electron beams  

International Nuclear Information System (INIS)

International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the absorbed dose in materials ...

2007-08-01

283

Damage process and luminescent characteristics in silica glasses under ion irradiation  

International Nuclear Information System (INIS)

Full text of publication follows: Understanding the dynamic irradiation effects on silica glasses is important for developing the diagnostic systems used in fusion and fission environments. While fundamental defects having an un-pared electron such as the E' center have been extensively studied, the neutral oxygen deficiency defects have been insufficiently clarified for lack of the detection methods. The ion induced luminescence is one of the probes that can be used to detect non-paramagnetic defects, and to observe creation and annihilation behavior dynamically. In the present study, we examined the characteristics of the ion induced luminescence such as energy, fluence flux and temperature dependence of the luminescence efficiency to analyze damage process quantitatively. Samples of SiO2 glasses were commercially available fused and synthesized silica glasses, produced by Toshiba Ceramics, Co. Ltd.. A thin films of SiO2 deposited on a Si ...

2007-12-10

284

Particle emission from low energy nuclear reactions in solids. Preliminary results  

Energy Technology Data Exchange (ETDEWEB)

TiH{sub 2} and TiD{sub 2} thick targets were bombarded with 100 to 200 keV protons or deuterons. Evidence for nuclear reactions was obtained by means of a surface barrier particle detector. Deuteron irradiation of TiD{sub 2} produced these observations: copious {approx}2.5 MeV neutrons and {approx}3 MeV protons from direct D-D reactions; gamma rays from p,{gamma} and n,{gamma} reactions; {approx}14 MeV protons from the secondary d({sup 3}He, p){alpha} reaction; and a signal between {approx}6-12 MeV that Kasagi et al. has tentatively identified as protons from the fusion of three deuterium nuclei. However, this signal has in it a strong interference signal from either neutrons or gamma rays that directly deposit energy in the detector. This interference spectra was measured by placing a thick absorber in front of the detector that stops up to 20 MeV protons, but not gamma rays or neutrons. More experiments must be done before we can confirm or ...

2000-07-01

285

On Boron Diffusion in MgF{sub 2}  

Science.gov (United States)

The MgF{sub 2} monocrystals were irradiated at room temperature with 390 keV B{sup +} ions up to the fluence of 10{sup 16} cm{sup -2}. The irradiated samples were (isochronally and isothermally) annealed in high vacuum at the temperatures 200 deg. C, 300 deg. C, 400 deg. C, 500 deg. C, 600 deg. C and 700 deg. C for the times ranging from 2-100 hours. After each annealing step, the boron depth distribution was determined using the neutron depth profiling technique. As implanted, the depth distributions of boron exhibited standard Gaussian-like forms, but the evaluated profile parameters, R{sub P} = 960 nm and {delta}R{sub P} = 140 nm, were higher than those calculated using the SRIM code (R{sub P} = 870 nm and {delta}R{sub P} = 115 nm). Annealing at temperatures up to 400 deg. C did not change the depth profiles. Annealing at 600 deg. C, however, led to a one-way gradual transfer of the boron atoms from the site of ...

2009-03-10

286

A spatial sensitivity analysis technique for neutron and gamma-ray measurements  

International Nuclear Information System (INIS)

In the fields of medical imaging, geophysical well logging, and industrial radiography, it is often of interest to characterize the spatially distributed sensitivities of neutron and gamma-ray measurement devices to the physical properties of the materials being examined. For instance, one may wish to know how the count rate in a detector varies in response to small changes in the local density of the irradiated object as a function of position. Experimental determination of such sensitivity functions is often impractical. Consequently, we have developed a general three-dimensional Monte Carlo numerical technique that allows us to directly compute the differential sensitivity of an arbitrary integral response parameter, such as a time- or energy-discriminated count rate, with respect to the spatial distribution of macroscopic cross sections and sources in the irradiated medium. Sensitivities to object density, porosity, etc., can easily be ...

1992-09-08

287

Cellular dosimetry: Absorbed fractions for monoenergetic electron and alpha particle sources and S-values for radionuclides uniformly distributed in different cell compartments  

Energy Technology Data Exchange (ETDEWEB)

The importance of cellular dosimetry in both diagnostic and therapeutic nuclear medicine is becoming increasingly recognized. Experimental range-energy relations for electrons and alpha particles, along with derived geometric reduction factors, are used to calculate cellular absorbed fractions for these radiations. The resulting absorbed fractions are employed to calculate cellular S-values for several radionuclides. Cellular absorbed fractions for monoenergetic electron sources with energies ranging from 0.1 keV to 1 MeV, distributed uniformly in the source region, are calculated for several target {l_arrow} source combinations including cell{l_arrow}cell, cell{l_arrow}cell surface, nucleus{l_arrow}nucleus, nucleus {l_arrow}cytoplasm and nucleus {l_arrow}cell surface. Similar data are also provided for monoenergetic alpha particle sources with energies ranging from 3 to 10 MeV. S-values are also conveniently tabulated for ...

1994-02-01

288

Investigation by XRF and XRD of Zn and Fe in Fe{sub x} Zn{sub 1-x} thin films  

Energy Technology Data Exchange (ETDEWEB)

Fe{sub x}Zn{sub 1-x} alloys were electrochemically deposited on aluminum substrates from a sulfate bath. The K{beta}/K{alpha} x-ray intensity ratios of Zn and Fe in Fe{sub x}Zn{sub 1-x} thin films have been experimentally studied. The energy dispersive x-ray fluorescence (EDXRF) technique was used to measure K x-ray photons. Samples were excited by using 59.5 keV photons emitted by a 50 mCi {sup 241}Am radioactive source. The emitted K x-rays were detected by an Ultra-LEGe detector having a resolution of 150 eV at 5.9 keV. In addition, the effect of bath composition on the phase structure was investigated by x-ray diffraction (XRD) analysis. The composition of the thin films was analyzed by atomic absorption spectrometry analysis. Iron content was shown to strongly affect the structure of Zn-Fe alloys. It was found that the K-shell x-ray intensity ratio changed in Fe{sub x}Zn{sub 1-x} thin films for different values of x. The reason for this ...

2008-12-15

289

Investigation by XRF and XRD of Zn and Fe in Fex Zn1-x thin films  

International Nuclear Information System (INIS)

FexZn1-x alloys were electrochemically deposited on aluminum substrates from a sulfate bath. The K?/K? x-ray intensity ratios of Zn and Fe in FexZn1-x thin films have been experimentally studied. The energy dispersive x-ray fluorescence (EDXRF) technique was used to measure K x-ray photons. Samples were excited by using 59.5 keV photons emitted by a 50 mCi 241Am radioactive source. The emitted K x-rays were detected by an Ultra-LEGe detector having a resolution of 150 eV at 5.9 keV. In addition, the effect of bath composition on the phase structure was investigated by x-ray diffraction (XRD) analysis. The composition of the thin films was analyzed by atomic absorption spectrometry analysis. Iron content was shown to strongly affect the structure of Zn-Fe alloys. It was found that the K-shell x-ray intensity ratio changed in FexZn1-x thin films for different values of x. The reason for this change may be that the electronegativity of iron is ...

2008-12-01

290

Defect engineering via ion implantation to control B diffusion in Si  

International Nuclear Information System (INIS)

The processes which are currently studied in the fabrication of B-doped ultra shallow junctions (USJ) usually involve a preamorphization step to reduce B channelling effect during implantation and to improve B electrical activation. At this stage a high amount of Si interstitial atoms (Is), which dramatically increases the B diffusivity, is introduced. The introduction of voids in Si is a promising tool to control B transient enhanced diffusion (TED), because of their ability to capture Is. In this work the efficiency of a cavity band to reduce B TED is checked in silicon interstitial supersaturation conditions, obtained by high dose Si implantation. He is implanted either at 10 keV or at 50 keV with a fluence of 5 x 10"1"6 cm"-"2. Conventional techniques to introduce and activate the B (conventional ion implantation and rapid thermal annealing (RTA)) are applied in order to have a better control of the technological process to focus on the ...

2009-03-15

291

Anode length optimization in a modified plasma focus device for optimal x-ray yields  

International Nuclear Information System (INIS)

The effect of anode length and operating gas pressure on the x-ray emission from a nitrogen-filling modified plasma focus device has been investigated. The time-resolved investigation of x ray was carried out by using a five-channel photodiode x-ray spectrometer. The maximum x-ray yield is seen to increase with the increase in the anode length from 110 to 125 mm. Further increase in the anode length to 130 mm causes the x-ray yields to decrease. The highest x-ray yield of 4.5 J into 4#pi# sr was found for 125 mm anode length, which is 0.2% of the input energy. The average x-ray photon energy was estimated by using half-value thickness method and found to be 8.4 keV. The electron temperature of the plasma was estimated to be around 3 keV by x-ray intensity ratio method. The space-resolved x-ray-emitting zones for all the anodes were captured by a pinhole-based x-ray imaging camera and the images were scanned for different ...

2006-01-01

292

{gamma}-Irradiation-induced preparation of Ag and Au nanoparticles and their characterizations  

Energy Technology Data Exchange (ETDEWEB)

Using {gamma}-irradiation-induced reduction in the field of a {sup 60}Co {gamma}-ray source, colloidal silver and gold nanoparticles were prepared from their corresponding metal salts in aqueous solution and compared with those by chemical reduction. The radiation-based method provided silver nanoparticles with higher concentration and narrower size distribution than those obtained by chemical reduction method while there was no significant difference between the two strategies for the preparation of gold nanoparticles. {gamma}-Irradiation of 1.0 x 10{sup -3} M AgNO{sub 3} solution resulted in nearly 100 times more highly concentrated silver colloids than those by citrate reduction. Furthermore, the radiation method could lead to more highly concentrated silver colloids by simply increasing the concentration of AgNO{sub 3} solution up to 2.0 x 10{sup -2} M. The two metal nanoparticles prepared by the two different methods were characterized by ...

2007-10-15

293

Novel InN growth method under In-rich condition on GaN/Al2O3(0001) templates  

International Nuclear Information System (INIS)

A novel technique is proposed for the growth of an InN film on a GaN/Al2O3(0001) template by radio-frequency plasma-excited molecular beam epitaxy (RF-MBE). The method involves 1) InN growth under an In-rich condition and 2) additional nitrogen radical irradiation after the InN growth under an In-rich condition. Excess In that appeared on the InN surface in the InN growth under an In-rich condition is transformed to InN by the additional nitrogen radical irradiation. The effective V/III ratio is easily controlled by monitoring the intensity in a reflection high-energy electron diffraction (RHEED) pattern. The growth of the InN film by repeating the InN growth under an In-rich condition and the additional nitrogen radical irradiation is also demonstrated. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

2009-06-01

294

Irradiation of food  

International Nuclear Information System (INIS)

Processing of food with ionizing radiation is a method suitable to enhance shelf-life and hygienic quality. Up to a dose of 10 kGy the method is considered wholesome. In many countries the practical use of food irradiation is increasing, however, in the Federal Republic of Germany the process is strictly forbidden. Applications and methods for radiation processing of food are compiled, limits and prospects are explained, and advantages and disadvantages are compared with traditional methods. Identification of irradiated foods and dosimetry and process control for radiation processing of food are areas where further research is needed. Continuous processing of particulate foods in bulk is an application where electron accelerators might be profitable. Beam parameters and velocity distribution of food particles in the treatment area can be matched for an effective result. Thus, dose distribution can be adjusted for ...

295

Hemoglobin of mice with radiation-induced mutations at the hemoglobin loci  

International Nuclear Information System (INIS)

Chemical analyses were done on the abnormal hemoglobins of the five (101 x SEC)F_1 offspring of X- irradiated adult SEC mice to determine which hemoglobin genes were expressed in each hemoglobin variant. Three offspring of irradiated SEC males did not express either of the two kinds of #alpha#-chains normally found in all SEC mice. The deficient #alpha#-chain synthesis caused these mice to exhibit an #alpha#-thalassemia similar to human #alpha#-thalassemia. Scanning electron microscopy was used to show that many erythrocytes of mice with #alpha#-thalassemia have bizarre shapes; e.g. many erythrocytes appeared flattened or had thorny projections (acanthocytes). One mutant with a tandem duplication of a segment of chromosome 7 (site of locus determining #beta#-chain structure) produced twice as much SEC as 101 #beta#-chain polypeptides. One mutant that probably arose by non-disjunction of chromosome 7's in its unirradiated ...

296

Displacement damage cross sections for neutron-irradiated silicon carbide  

International Nuclear Information System (INIS)

Displacements per atom (DPA) is a widely used damage unit for displacement damage in nuclear materials. Calculating the DPA for SiC irradiated in a particular facility requires a knowledge of the neutron spectrum as well as specific information about displacement damage in that material. In recent years significant improvements in displacement damage information for SiC have been generated, especially the energy required to displace an atom in an irradiation event and the models used to describe electronic and nuclear stopping. Using this information, numerical solutions for the displacement functions in SiC have been determined from coupled integro-differential equations for displacements in polyatomic materials and applied in calculations of spectral-averaged displacement cross sections for SiC. This procedure has been used to generate spectrally averaged displacement cross sections for SiC in a number of reactors used ...

2002-12-01

297

Displacement Damage Cross Sections for Neutron-irradiated Silicon Carbide  

Energy Technology Data Exchange (ETDEWEB)

Displacements per atom (DPA) is a widely used damage unit for displacement damage in nuclear materials. Calculating the DPA for SiC irradiated in a particular facility requires a knowledge of the neutron spectrum as well as specific information about displacement damage in that material. In recent years significant improvements in displacement damage information for SiC have been generated, especially the energy required to displace an atom in an irradiation event and the models used to describe electronic and nuclear stopping. Using this information, numerical solutions for the displacement functions in SiC have been determined from coupled integro-differential equations for displacements in polyatomic materials and applied in calculations of spectral-averaged displacement cross sections for SiC. This procedure has been used to generate spectrally averaged displacement cross sections for SiC in a number of reactors used ...

2002-12-01

298

Development and clinical experience of C-arm type radiosurgery system or three dimensional therapy system  

Energy Technology Data Exchange (ETDEWEB)

Authors developed a C-arm type radiosurgery system of the linear accelerator suitable for stereotactic radiation therapy and a software for arranging 3-dimensional therapy in the system. In this system, the gantry far conical irradiation of 4 MV (0.6-3 Gy/min) and 6 MV (0.9-4.5 Gy/min) X ray or electron beam for the therapy was connected to a newly designed C-arm and was made capable of rotating around either of the axes crossing vertically. With this system, it became unnecessary to move the bed table of the patient for getting suitable distribution of radiation dose. The local accuracy which was measured by the CCD videocamera on the gantry, was within 0.5 mm from the radiation center. The system made it possible to shorten the irradiation time and to improve the local accuracy of irradiating site. The clinical trial was begun from June, 1996. (K.H.)

1996-10-01

301

Total skin electron beam and total nodal irradiation for treatment of patients with cutaneous T-cell lymphoma  

Energy Technology Data Exchange (ETDEWEB)

Sixteen patients with advanced cutaneous T-cell lymphoma (CTCL) with or without lymph node involvement, but without evidence of extranodal manifestations, were treated with a combination of total skin electron beam therapy (TSEB) and total nodal irradiation (TNI). Fourteen (87%) patients achieved a complete response (CR) lasting from 1 to 84+ months (median, 8+ months) from the completion of treatment. The best results occurred in 6 patients with pretumorous intracutaneous CTCL (Stages IB and IIA) where the CR has lasted in all patients from 8 to 84+ months (median about 27+ months). Radiotherapy was well tolerated with the major toxicity being bone marrow suppression. The authors conclude that combined TSEB and TNI is a relatively safe and effective treatment for patients with CTCL prior to the development of lymph node involvement. Long-term follow-up is needed to assess the curative potential of this treatment.

1985-06-01

302

Photochemical synthesis of ZnO/Ag nanocomposites  

Energy Technology Data Exchange (ETDEWEB)

Composite ZnO/Ag nanoparticles have been formed via the photocatalytic reduction of silver nitrate over the ZnO nanocrystals, their optical, electrophysical and photochemical properties have been investigated. Mie theory has been applied to analyze the structure of the absorption spectra of ZnO/Ag nanocomposite. The irradiation effects upon the optical properties of ZnO/Ag nanostructure have been investigated. It has been found that the irradiation of ZnO/Ag nanoparticles results in electrons accumulation by both the semiconductor and the metallic components of the nanocomposite. It has been found that silver nitrate can be photochemically deposited onto the surface of ZnO nanoparticles under the illumination with the visible light in the presence of the sensitizer - methylene blue. Kinetics of the sensitized Ag(I) photoredution has been studied. It has been concluded that the key stage of this process is the ...

2007-06-15

303

Irradiating the groin nodes without breaking a leg: A comparison of techniques for groin node irradiation  

International Nuclear Information System (INIS)

The purpose of this study was to determine the optimal technique for delivering postoperative radiotherapy for vulvar cancer and other tumors requiring treatment of the inguinal nodes. This project compared tumor coverage and normal tissue sparing for the 5 main radiotherapy techniques that are used to treat vulvar cancer. The intensity-modulated radiation therapy (IMRT) plan was undesirable because it resulted in an excessive dose to portions of the central pelvic structures. The photon thunderbird with skin match was unacceptable because it underdosed a portion of the groin region. The electron thunderbird was ideal for thin patients but was not applicable for most patients because of excessive dose to the skin and subcutaneous tissues. The photon through-and-through and the photon thunderbird with deep match were acceptable in most situations. In thin patients, where the depth of the inguinal vessels is less than 3 cm, the electron ...

304

Characterization of spent fuel approved testing material--ATM-104  

Energy Technology Data Exchange (ETDEWEB)

The characterization data obtained to date are described for Approved Testing Material 104 (ATM-104), which is spent fuel from Assembly DO47 of the Calvert Cliffs Nuclear Power Plant (Unit 1), a pressurized-water reactor. This report is one in a series being prepared by the Materials Characterization Center at Pacific Northwest Laboratory (PNL) on spent fuel ATMs. The ATMs are receiving extensive examinations to provide a source of well-characterized spent fuel for testing in the US Department of Energy Office of Civilian Radioactive Waste Management (OCRWM) Program. ATM-104 consists of 128 full-length irradiated fuel rods with rod-average burnups of about 42 MWd/kgM and expected fission gas release of about 1%. A variety of analyses were performed to investigate cladding characteristics, radionuclide inventory, and redistribution of fission products. Characterization data include (1) fabricated fuel design, irradiation history, and subsequent ...

1991-12-01

305

Study of the Smith-Purcell effect in the relativistic regime  

International Nuclear Information System (INIS)

We propose to investigate the spontaneous emission of radiation arising out of the interaction of a relativistic electron beam with a metallic grating (the Smith-Purcell effect). The work will concentrate, primarily, in the 50-120 #mu#m part of the infrared spectrum and will be an extension of the work begun by the Oxford-Dartmouth-Essex collaboration; one of the early objectives of the project will be to develop a quantitative understanding of the power spectrum of the emitted radiation over a wide range of emission angles. In particular, the limits of relativistic peaking of forward directed emission will be investigated. The electron beam will be produced by laser irradiation of a metallic cathode in the terminal of a small Van de Graff accelerator located in the Technische Universitaet, Muenchen. Beam energies will be in the range of 2 - 4 MeV. Initial tests on photoproduction of electrons have ...

1995-08-21

306

Photoluminescence, optically stimulated luminescence, and thermoluminescence study of RbMgF3:Eu2+  

International Nuclear Information System (INIS)

Optically stimulated luminescence (OSL) and thermoluminescence are observed in polycrystalline RbMgF3:Eu2+ after x-ray, ?-ray, or ? irradiation. The main electron traps are F-centers but there are other unidentified traps. The main hole traps at room temperature are probably Eu3+ and thermal or optical stimulation leads to electron-hole recombination at the Eu3+ site and Eu2+ emissions arising from 6PJ to 8S7/2 and 4f5d(Eg) to 8S7/2 transitions. We find that some of the electron traps can be emptied by infrared stimulation and all of the electron traps can be emptied by white light stimulation. The OSL dark decay is long and exceeds 5 days for traps that are emptied by white light stimulation after initial infrared bleaching. Our results show that this compound can be used as a radiation dosimeter for intermediate dose levels where the 87Rb self-dose does not significantly affect ...

2009-01-15

307

Schottky barrier modulation on silicon nanowires  

Science.gov (United States)

Oxide charge on the sidewalls of SiO{sub 2} embedded silicon wires with 20x20 nm{sup 2} cross section is shown to influence the Schottky barrier height for Pd{sub 2}Si/Si junctions positioned on the end surfaces of the wires. Compared with results on planar silicon surfaces, the electron barrier height is 0.3 eV lower for wires investigated as fabricated. By increasing the oxide charge through irradiation by ultraviolet light, the electron barrier decreases by an additional 0.15 eV and the hole barrier correspondingly increases by about the same amount. The phenomenon is explained by assuming an oxide charge density in the range of 10{sup 12} cm{sup -2}.

2007-03-26

308

Physical properties of wood-polymer composites prepared by an electron beam accelerator  

Energy Technology Data Exchange (ETDEWEB)

The dual characteristics in the performance of polymers in wood-polymer composites systems have been pursued with regard to the resolution of mechanical anisotropy of wood and the improvement in dimensional stability. The objective of the present study is to pursue the polymerization mechanism in wood under electron beam irradiation and the temperature dependence of polymer-wood interactions induced at various levels of higher order structure of wood in order to understand the polymer performance. Veneers used in the study were of rotary-cut beech (Fagus crenata Blume) 0.65 mm thick. All samples were oven-dried in vacuo at 80/sup 0/C for 30 hr. The monomers used in the study were methyl methacrylate, styrene, acrylic acid, acrylonitrile, and unsaturated polyester. Experimental details are given. Results are given and discussed.

1981-01-01

309

Electron beam induced reactions in metal/Si systems  

Energy Technology Data Exchange (ETDEWEB)

Thin Pt, Pd, Pt/sub 2/Si, PtSi, Pd/sub 2/Si, Ni, Mo, W, Nb, Ti, V films deposited on Si single crystal were treated by using electron beam pulses of 60 ns duration in the 0.4-4 J/cm/sup 2/ energy density range. Irradiation of these structures produces at the same time many phases. Post-thermal annealing of the reacted layer induces the formation of a stable phase, the same obtained by only thermal treatment in a conventional furnace. A linear relationship between the energy density range and the lowest eutectic temperature of the compounds formed has been found. Further SEM observations seem to identify a liquid layer from which the phases are forming by subsequent fast cooling.

1982-01-01

310

Electron beam induced reactions in metal/Si systems  

International Nuclear Information System (INIS)

Thin Pt, Pd, Pt_2Si, PtSi, Pd_2Si, Ni, Mo, W, Nb, Ti, V films deposited on Si single crystal were treated by using electron beam pulses of 60 ns duration in the 0.4-4 J/cm"2 energy density range. Irradiation of these structures produces at the same time many phases. Post-thermal annealing of the reacted layer induces the formation of a stable phase, the same obtained by only thermal treatment in a conventional furnace. A linear relationship between the energy density range and the lowest eutectic temperature of the compounds formed has been found. Further SEM observations seem to identify a liquid layer from which the phases are forming by subsequent fast cooling. (author).

311

Single event effects in the pixel readout chip for BTeV  

Energy Technology Data Exchange (ETDEWEB)

In future experiments the readout electronics for pixel detectors is required to be resistant to a very high radiation level. In this paper we report on irradiation tests performed on several preFPIX2 prototype pixel readout chips for the BTeV experiment exposed to a 200 MeV proton beam. The prototype chips have been implemented in commercial 0.25 {micro}m CMOS processes following radiation tolerant design rules. The results show that this ASIC design tolerates a large total radiation dose, and that radiation induced Single Event Effects occur at a manageable level.

2001-12-07

312

Radiation-induced chemical modification of wood  

International Nuclear Information System (INIS)

The results of theoretical and experimental investigations, describing the effect of ionizing radiation on wood and its main components and methods for production of wood-plastic composites by means of radiation-induced chemical modification are generalized. Domestic and foreign experience in their production is systematized; physico-mechanical characteristics of new material, simulation and calculation of irradiating devices, as well as calculation and experimental study of #gamma#-radiation attenuation both by wood material and by wood of different species are given. Gamma sources ("6"0Co isotope, a hot loop of a nuclear reactor) as well as electron accelerators are considered as ionizing radiation sources.

1985-01-01

313

Preparation of silver nanofluid by the submerged arc nanoparticle synthesis system (SANSS)  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is fabrication and characterization of silver nanofluid by the submerged arc nanoparticle synthesis system (SANSS). The silver metal electrodes under the electrical discharge will melt and evaporate rapidly and condense to form the nanoparticles in the lower temperature dielectric liquid and produce the suspended nanoparticle. The results showed that the spherical nanosilver particle formed in the ethylene glycol and the mean particle size is about 12.5 nm. The prepared silver nanofluid was irradiated under the 410 nm visible light, electrons could be excited from the valence band to the conduction band. The silver nanofluid more closely resembles Newtonian fluids.

2007-05-31

314

Negative charges in liquid hydrogen and deuterium  

Energy Technology Data Exchange (ETDEWEB)

The temperature and pressure dependence of the mobilities of negative charges injected into liquid hydrogen and deuterium have been measured. The authors propose the existence of two types of charge carriers in liquid parahydrogen. One is a bubble with an electron inside while the other has higher mobility. Relaxation of the current through liquid hydrogen was observed. It is suggested that in liquid and solid hydrogen under {beta}-irradiation neutral complexes are created which can trap the negative charges and have a lifetime of about 10 hours. 6 refs., 5 figs.

1992-11-01

315

Entangled quantum currents in distant mesoscopic Josephson junctions  

Energy Technology Data Exchange (ETDEWEB)

Two mesoscopic SQUID rings which are far from each other are considered. A source of two-mode nonclassical microwaves irradiates the two rings with correlated photons. The Josephson currents are in this case quantum mechanical operators, and their expectation values with respect to the density matrix of the microwaves yield the experimentally observed currents. Classically correlated (separable) and quantum mechanically correlated (entangled) microwaves are considered, and their effect on the Josephson currents is quantified. Results for two different examples that involve microwaves in number states and coherent states are derived. It is shown that the quantum statistics of the tunnelling electron pairs through the Josephson junctions in the two rings are correlated.

2004-12-22

316

Compression, bend, and impact testing of some tropical wood-polymer composites  

International Nuclear Information System (INIS)

The compressive and bending strengths of a local tropical wood (Kapur-Dryobalanop sp.) were improved significantly by suitable impregnation of polymeric monomers (methylmethacrylate, methylmethacrylate - 5% dioxane and vinyl acetate) into the wood cellular structure and subsequent irradiation to form a wood-polymer composite. Statistical analysis revealed a linear relationship between increase in the strengths and the percentage of polymer impregnated. Fractographic analysis of the impact fractured surfaces under the scanning electron microscope showed the nature of the wood-polymer interface, which could account for the increase in the compressive and bending strengths. (author).

1985-01-01

317

Using Gamma-Ray Burst Prompt Emission to Probe Relativistic Shock Acceleration  

CERN Document Server

It is widely accepted that the prompt transient signal in the 10 keV - 10 GeV band from gamma-ray bursts (GRBs) arises from multiple shocks internal to the ultra-relativistic expansion. The detailed understanding of the dissipation and accompanying acceleration at these shocks is a currently topical subject. This paper explores the relationship between GRB prompt emission spectra and the electron (or ion) acceleration properties at the relativistic shocks that pertain to GRB models. The focus is on the array of possible high-energy power-law indices in accelerated populations, highlighting how spectra above 1 MeV can probe the field obliquity in GRB internal shocks, and the character of hydromagnetic turbulence in their environs. It is emphasized that diffusive shock acceleration theory generates no canonical spectrum at relativistic MHD discontinuities. This diversity is commensurate with the significant range of spectral indices discerned in ...

2010-01-01

318

Standardization of "2"4"1Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting  

International Nuclear Information System (INIS)

The nuclide "2"4"1Am decays by alpha emission to "2"3"7Np. Most of the decays (84.6%) populate the excited level of "2"3"7Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of "2"4"1Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

2009-09-07

319

Neutrino emission in neutron matter from magnetic moment interactions  

CERN Document Server

Neutrino emission drives neutron star cooling for the first several hundreds of years after its birth. Given the low energy ($\\sim$ keV) nature of this process, one expects very few nonstandard particle physics contributions which could affect this rate. Requiring that any new physics contributions involve light degrees of freedom, one of the likely candidates which can affect the cooling process would be a nonzero magnetic moment for the neutrino. To illustrate, we compute the emission rate for neutrino pair bremsstrahlung in neutron-neutron scattering through photon-neutrino magnetic moment coupling. We also present analogous differential rates for neutrino scattering off nucleons and electrons that determine neutrino opacities in supernovae. Employing current upper bounds from collider experiments on the tau magnetic moment, we find that the neutrino emission rate can exceed the rate through neutral current electroweak interaction by a ...

2004-01-01

320

Molar extinction coefficients of some fatty acids  

International Nuclear Information System (INIS)

The attenuation of gamma rays in some fatty acids, viz. formic acid (CH_2O_2), acetic acid (C_2H_4O_2), propionic acid (C_3H_6O_2), butyric acid (C_4H_8O_2), n-hexanoic acid (C_6H_1_2O_2), n-caprylic acid (C_8H_1_6O_2), lauric acid (C_1_2H_2_4O_2), myristic acid (C_1_4H_2_8O_2), palmitic acid (C_1_6H_3_2O_2), oleic acid (C_1_8H_3_4O_2) and stearic acid (C_1_8H_3_6O_2), has been measured at the photon energies 81, 356, 511, 662, 1173 and 1332 keV. Experimental values for the molar extinction coefficient, the effective atomic number and the electron density have been derived and compared with theoretical calculations. There is good agreement between experiment and theory.

2002-10-01

321

M X-ray production in Nd, Gd, Ho and Lu by 1-6 MeV lithium ions  

Energy Technology Data Exchange (ETDEWEB)

M-shell X-rays of the rare-earth elements {sub 60}Nd, {sub 64}Gd, {sub 67}Ho and {sub 71}Lu were measured for lithium ion bombardment in the energy range 1.0-6.0 MeV. The M-shell X-rays with energies of 0.978-1.631 keV were detected with a LINK analytical detector. The efficiency of the detector was determined by using the known atomic-field bremsstrahlung cross-sections from low energy electron beams and K-shell X-ray measurements with light projectiles. The measured cross-sections are compared to the predictions of the first Born approximation and the ECPSSR (energy loss and Coulomb deflection effects, perturbed stationary state approximation with relativistic correction) theories. The best theoretical description of the present data is given by the ECPSSR theory, even though the discrepancy between data and theory is increasing at higher projectile energies.

2004-06-01

322

Interactions of ion-implantation-induced interstitials with boron at high concentrations in silicon  

Energy Technology Data Exchange (ETDEWEB)

Ion implantation of Si (60 keV, 1{times}10{sup 14}/cm{sup 2}) has been used to introduce excess interstitials into silicon predoped with high background concentrations of B, which were varied between 1{times}10{sup 18} and 1{times}10{sup 19}/cm{sup 3}. Following post-implantation annealing at 740{degree}C for 15 min to allow agglomeration of the available interstitials into elongated {l_brace}311{r_brace} defects, the density of the agglomerated interstitials was determined by plan-view transmission electron microscopy observation of the defects. We report a significant reduction in the fraction of excess interstitials trapped in {l_brace}311{r_brace} defects as a function of boron concentration, up to nearly complete disappearance of the {l_brace}311{r_brace} defects at boron concentrations of 1{times}10{sup 19}/cm{sup 3}. The reduction of the excess interstitial concentration is interpreted in terms of boron-interstitial clustering, and ...

1996-09-01

323

Interactions of ion-implantation-induced interstitials with boron at high concentrations in silicon  

International Nuclear Information System (INIS)

Ion implantation of Si (60 keV, 1x10"1"4/cm"2) has been used to introduce excess interstitials into silicon predoped with high background concentrations of B, which were varied between 1x10"1"8 and 1x10"1"9/cm"3. Following post-implantation annealing at 740 degree C for 15 min to allow agglomeration of the available interstitials into elongated #left brace#311#right brace# defects, the density of the agglomerated interstitials was determined by plan-view transmission electron microscopy observation of the defects. We report a significant reduction in the fraction of excess interstitials trapped in #left brace#311#right brace# defects as a function of boron concentration, up to nearly complete disappearance of the #left brace#311#right brace# defects at boron concentrations of 1x10"1"9/cm"3. The reduction of the excess interstitial concentration is interpreted in terms of boron-interstitial clustering, and implications for transient-enhanced ...

324

Inelastic-energy-loss measurements of multiple N- and M-shell excitations in 0.3- to 1.2-MeV Xe"+-Xe collisions  

International Nuclear Information System (INIS)

The inelastic energy losses for single collisions of Xe"+ ions with Xe targets have been measured for incident ion energies from 0.3 to 1.2 MeV and for scattering angles from 3"0 to 20"0. The energy losses were found to range from 1 to 11 keV with distinct steps at distances of closest approach of 0.22 and 0.12 A. By comparing these data with earlier ionization data by the same authors these steps are shown to be caused by M-shell excitation. Other excitations observed in the ionization data may be attributed to N-shell excitation. The distances of closest approach at which these excitations occur agree well with calculations by Eichler and Wille and co-workers, giving further evidence of the usefulness of Fano and Lichten's one-electron molecular model and these calculations.

325

Design of a GaAs X-ray imaging sensor with integrated HEMT readout circuitry  

CERN Document Server

A new monolithic semi-insulating (SI) GaAs sensor design for X-ray imaging applications between 10-100keV has been proposed. Monolithic pixel detectors offer a number of advantages over hybrid bump-bonded detectors, such as high device yield, low costs and are easier to produce large scale arrays. In this thesis, an investigation is made of the use of a SI GaAs wafer as both a detector element and substrate for the epitaxially grown High Electron Mobility Transistors (HEMTs). The design of the HEMT transistors, optimised for this application, were produced with the aid of the Silvaco 'Virtual Wafer Fab' simulation package. It was determined that the device characteristics would consist of a small positive threshold voltage, a low off-state drain current and high transconductance. The final HEMT transistor design, that would be integrated to a pixel detector, had a threshold voltage of 0.17V, an off-state leakage current of approx 1nA and a ...

2002-01-01

326

Correlation between ion beam parameters and physical characteristics of nanostructures fabricated by focused ion beam  

International Nuclear Information System (INIS)

We report a study of the physical characteristics of the pillars of C, Pt and W grown by 10-30 keV Ga focused ion beam (FIB) as a function of Ga ion flux, and present a quantitative analysis of the elements using energy-dispersive analysis of X-rays (EDAX). All the FIB grown pillars exhibit a rough morphology with whisker like protrusions on the cylindrical surface and broadening of the base as compared to the nominal size. For a constant fluence, the height of the pillar initially increases and then reduces after going through a maximum as a function of ion flux in all the cases. The compositional analysis shows good metallic quality for Pt structures but reveals significant contamination of Ga in C and Ga and C in W structures at higher ion fluxes. Explanation to all these observations has been sought in the light of secondary ion and electron effects and the different processes involved which lead to the FIB induced deposition.

2008-04-01

327

Atomistic calculations of ion implantation in Si: Point defect and transient enhanced diffusion phenomena  

Energy Technology Data Exchange (ETDEWEB)

A new atomistic approach to Si device process simulation is presented. It is based on a Monte Carlo diffusion code coupled to a binary collision program. Besides diffusion, the simulation includes recombination of vacancies and interstitials, clustering and re-emission from the clusters, and trapping of interstitials. We discuss the simulation of a typical room-temperature implant at 40 keV, 5{times}10{sup 13} cm{sup {minus}2} Si into (001)Si, followed by a high temperature (815{degree}C) anneal. The damage evolves into an excess of interstitials in the form of extended defects and with a total number close to the implanted dose. This result explains the success of the {open_quote}{open_quote}+1{close_quote}{close_quote} model, used to simulate transient diffusion of dopants after ion implantation. It is also in agreement with recent transmission electron microscopy observations of the number of interstitials stored in (311) defects. ...

1996-01-01

328

Atomistic calculations of ion implantation in Si: Point defect and transient enhanced diffusion phenomena  

International Nuclear Information System (INIS)

A new atomistic approach to Si device process simulation is presented. It is based on a Monte Carlo diffusion code coupled to a binary collision program. Besides diffusion, the simulation includes recombination of vacancies and interstitials, clustering and re-emission from the clusters, and trapping of interstitials. We discuss the simulation of a typical room-temperature implant at 40 keV, 5x10"1"3 cm"-"2 Si into (001)Si, followed by a high temperature (815 degree C) anneal. The damage evolves into an excess of interstitials in the form of extended defects and with a total number close to the implanted dose. This result explains the success of the open-quote open-quote+1 close-quote close-quote model, used to simulate transient diffusion of dopants after ion implantation. It is also in agreement with recent transmission electron microscopy observations of the number of interstitials stored in (311) defects. copyright 1996 American Institute ...

329

Complex Spatio-Spectral Structure of Diffuse X-Ray emission in the ...  

Science.gov (United States)

SN 1987A: Soft X-Ray Intensity Ratio. 2002-12 to 2000-12. 2005-7 to 2002-12. Contours: 2002-12. (0.5 2 keV). (0.5 2 keV). Contours: 2005-7 ...

330

Spectroscopic characterization of alkane radical cations: Pt. 1  

International Nuclear Information System (INIS)

Radical cations of various 3-methylalkanes (C_6-C_1_4) have been produced and stabilized by #gamma#-irradiation of the corresponding neutral compounds in saturated chlorofluorocarbon and perfluorocarbon matrices at 77 K. The perfluorocarbon matrices appeared more suitable for studies of the lighter radical cations, whereas the chlorofluorocarbon matrices were more suited for studies of the heavier radical cations; intermediary cations could be studied in both types of matrices. After irradiation, electronic absorptions associated with both the matrix and the alkane additive were observed. Pure spectra of the 3-methylalkane radical cations were obtained by difference spectrometry, after selective elimination of these cations by illumination. The electronic absorption spectra of the 3-methylalkane radical cations consist in all cases of a single broad absorption band. The spectral position of this band ...

1989-01-01

331

Irradiation-assisted stress corrosion cracking of austenitic stainless steels: Recent progress and new approaches  

Energy Technology Data Exchange (ETDEWEB)

Irradiation-assisted stress corrosion cracking (IASCC) of several types of BWR field components fabricated from solution-annealed austenitic stainless steels (SSs), including a core internal weld, were investigated by means of slow-strain-rate test (SSRT), scanning electron microscopy (SEM), Auger electron spectroscopy (AES), and field-emission-gun advanced analytical electron microscopy (FEG-AAEM). Based on the results of the tests and analyses, separate effects of neutron fluence, tensile properties, alloying elements and major impurities identified in the American Society for Testing and Materials (ASTM) specifications, minor impurities, water chemistry, and fabrication-related variables were determined. The results indicate strongly that minor impurities not specified by the ASTM-specifications play important roles, probably through a complex synergism with grain-boundary Cr depletion. These ...

1996-09-01

332

In vivo and in vitro evaluation of dota-lanreotide radiolabelled with gallium-67  

International Nuclear Information System (INIS)

One of the refinements of modern Nuclear Medicine is the capacity of providing dynamic and kinetics images of the administered radiopharmaceutical, reproducing its transport mechanism, action sites, receptor binding and excretion route. With the continues technological advances new radiopharmaceuticals have been developed in order to express higher specificity and with higher characters of affinity between receptor/complex. One radiopharmaceutical is formed by a reagent or bio molecule that has in its structure a radioisotope, that has the objectives of carrying it to the organs of affinity or to benign or malign tumoral process. Somatostatin inhibits the growing and proliferation of several tumoral cells. Somatostatin analogs bind to somatostatic receptors that are expressed in different kind of neoplasia DOTA-LANREOTIDE (DOTALAN) is an octapeptide analog to somatostatin. The interest of labeling the bio conjugate with gallium-67 in Nuclear Medicine comes from its physical, chemical ...

333

Packaging materials for use in radiation processing of foods  

International Nuclear Information System (INIS)

In radiation processing of food, the product often has to be prepackaged to prevent microbial recontamination during and after irradiation. The packaging material is exposed to radiation during radiation processing and radiation stability is a key consideration in the selection of packaging materials. The effects of ionizing radiation on many food packaging materials at the dose levels recommended for food precessing can be minimized by selecting appropriate radiation resistant materials. It is important to select materials in which chemicals formed as a result of the radiation treatment do not migrate and interact with the food, affecting its organoleptic and toxicological aspects. It is also important to select materials in which the physical properties are not altered to the extent they cannot resist damage during commercial production, shipment and storage. Radiation treatment of food may be classified broadly into two categories: 1. Processes requiring doses ...

334

Clinical studies on cancer of the tongue  

Energy Technology Data Exchange (ETDEWEB)

Thirty-nine previously untreated patients with squamous cell carcinoma of the tongue were treated by irradiation or a combination of irradiation and surgery, with or without chemotherapy, between January 1971 and December 1980. All of the patients had a follow-up period of at least nine years. Twenty-two patients were men and 17 were women. The average age was 50.1 years, with a range of 30 to 74 years. The absolute five-year survival rate was 82.1% and the cumulative ten-year survival rate 76.9% for these 39 patients. Cervical node metastases were clinically found on admission in 14 patients whose five-year survival rate was 64.3%, whereas it was 92.0% for 25 patients without metastasis. The absolute five-year survival rate decreased from 92.3% for patients with stage I lesions to 90.9%, 87.5% and 42.9% for those with stage II, stage III and stage IV lesions, respectively. Most of the patients received external irradiation ...

1990-12-01

335

8"+ isomers in N=48 isotones and E2 polarization charges  

International Nuclear Information System (INIS)

... charges energy levels gamma spectra half-life isomeric nuclei kev range

1972-05-01

336

Extension of improved particle and energy confinement regime in the core of LHD plasma  

International Nuclear Information System (INIS)

Recent two major topics of Large Helical Device (LHD) towards fusion relevant conditions, high-density operation and high-ion-temperature operation, are reported. Super dense core plasma was obtained by the combination of repetitive hydrogen ice pellet injection and high power neutral beam injection (NBI) heating. A very peaked density profile with the highest central density of 1.1x1021 m-3 was produced showing that the particle transport was suppressed very well in the plasma core. The spatial density varies as the position of magnetic axis (Rax), and the steepest profile is obtained at Rax=3.95 m. The highest central ion temperature of 5.6 keV was obtained in hydrogen plasma at electron density of 1.6 x 1019 m-3 by NBI, where a peaked ion-temperature profile with internal ion energy transport barrier was observed. The profile of electron temperature did not change much and was broad even when the ion temperature had a ...

2009-06-01

337

Central engine of quasars and AGNs: a relativistic proton radiative shock  

International Nuclear Information System (INIS)

Active galactic nuclei (AGNs) and quasars (QSOs) appear to emit roughly equal energy per decade from radio to gamma-ray energies (e.g. Ramaty and Ligenfelter 1982). This argues strongly for a nonthermal radiation mechanism (see Rees 1984). In addition, statistical studies have indicated that the spectra of these objects in the IR-UV and 2 to 50 keV x-ray band, can be fitted very well with power laws of specific indices. These spectral indices do not seem to depend on the luminosity or morphology of the objects (Rothschild et al. 1983; Malkan 1984), and any theory should account for them in a basic and model independent way. If shocks accelerate relativistic protons via the first-order Fermi mechanism (e.g. Axfor 1981), the radiating electrons can be produced as secondaries throughout the source by proton-proton (p-p) collisions and pion decay, thus eliminating Compton losses (Protheroe and Kazanas 1983). As shown by Kazanas (1984), if ...

1985-08-01

338

Radial dose distribution of 6.0 MeV/n #alpha#-particle in water  

International Nuclear Information System (INIS)

For the study of radiation biology and its application to radiotherapy, the double differential cross section of electron emission from water vapor induced by 6.0 MeV alpha particle beam is measured. The energy spectra of electrons ranging 7- 10000 eV are detected by the electrostatic analyzer and micro channel plate. The measurements are made at angles between 20 and 160 degrees. With use of this data set, the radial dose distribution in water is calculated by using KURBUC code. It is the Monte Carlo type code of the electron transport process, where the track of the electron is simulated through each individual interactions including elastic scattering, ionization cross section and total excitation cross section in case that electrons with certain energy are put in the liquid-density water. In order to understand the effect of radiation when the particle flux is injected in the ...

2003-08-17

339

Radioactive targets for neutron-induced cross section measurements  

Science.gov (United States)

Measurements using radioactive targets are important for the determination of key reaction path ways associated with the synthesis of the elements in nuclear astrophysics (sprocess), advanced fuel cycle initiative (transmutation of radioactive waste), and stockpile stewardship. High precision capture cross-section measurements are needed to interpret observations, predict elemental or isotopical ratios, and unobserved abundances. There are two new detector systems that are presently being commissioned at Los Alamos National Laboratory for very precise measurements of (n,{gamma}) and (n,f) cross-sections using small quantities of radioactive samples. DANCE (Detector for Advanced Neutron-Capture Experiments), a 4 {pi} gamma array made up of 160 BaF{sub 2} detectors, is designed to measure neutron capture cross-sections of unstable nuclei in the low-energy range (thermal to {approx}500 keV). The high granularity and high detection efficiency of DANCE, combined with ...

2004-01-01

340

Epidemiological survey of the effects of low level radiation dose: a comparative assessment  

Energy Technology Data Exchange (ETDEWEB)

This volume presents the collations tables of a six volume comparative epidemiological survey of the effects of low level radiation dose. Data are collated for the effects observed in the following irradiated groups:- Preconception irradiation, intra-uterine irradiation, childhood irradiation, adult irradiation. (UK).

1993-10-01

341

Structure of the triplet of low-lying states in sup 101 Mo  

Energy Technology Data Exchange (ETDEWEB)

The properties of the triplet of low-lying states in {sup 101}Mo have been studied through spectroscopy of the {gamma} radation following thermal neutron capture in {sup 100}Mo and {beta}-decay of {sup 101}Nb and through a measurement of the proton angular distributions in the {sup 100}Mo(d, p) reaction with 14 MeV deuteron energy. The half-lives of the 13.5 keV state and the 57.0 keV 5/2{sup +} state have been measured as 226(7) and 133(7) ns, respectively. These values and the quadrupole/dipole mixing ratios of the 13.5 keV and 43.5 keV transitions yield spin and parity 3/2{sup +} for the 13.5 keV level. The E2 components in the 13.5 (3/2{sup +}->1/2{sup +}) and 43.5 keV (5/2{sup +}->3/2{sup +}) transitions are {le} 8x10{sup -4} and 54(9)%, respectively. The possibility of an additional state near to the 57.0 keV level is discussed. ...

1991-06-01

342

Structure of the triplet of low-lying states in "1"0"1Mo  

International Nuclear Information System (INIS)

The properties of the triplet of low-lying states in "1"0"1Mo have been studied through spectroscopy of the #gamma# radation following thermal neutron capture in "1"0"0Mo and #beta#-decay of "1"0"1Nb and through a measurement of the proton angular distributions in the "1"0"0Mo(d, p) reaction with 14 MeV deuteron energy. The half-lives of the 13.5 keV state and the 57.0 keV 5/2"+ state have been measured as 226(7) and 133(7) ns, respectively. These values and the quadrupole/dipole mixing ratios of the 13.5 keV and 43.5 keV transitions yield spin and parity 3/2"+ for the 13.5 keV level. The E2 components in the 13.5 (3/2"+#->#1/2"+) and 43.5 keV (5/2"+#->#3/2"+) transitions are #<=# 8x10"-"4 and 54(9)%, respectively. The possibility of an additional state near to the 57.0 keV level is discussed. IBFM/PTQM calculations, taking into ...

343

Photocatalytic self-cleaning properties of cellulosic fibers modified by nano-sized zinc oxide  

International Nuclear Information System (INIS)

Nano-sized zinc oxide was synthesized and deposited onto cellulosic fibers using the sol-gel process at ambient temperature. The prepared materials were characterized using several techniques including scanning electron microscopy, transmission electron microscopy, diffuse reflectance spectroscopy, X-ray diffraction and thermogravimetric analysis. X-ray diffraction studies of the ZnO-coated fiber indicate formation of the hexagonal crystal phase which was satisfactory crystallized on the fiber surface. The electron micrographs show formation of zinc oxide nanoparticles within 10-15 nm in size which have been homogeneously dispersed on the fiber surface. The prepared materials show significant photocatalytic self-cleaning activity, which was monitored by diffuse reflectance spectroscopy. The photoactivity was studied upon measuring the photodegradation of methylene blue and eosin yellowish under UV-Vis ...

2011-03-31

344

Free-electron laser beam  

International Nuclear Information System (INIS)

The principle and history of free-electron laser (FEL), first evidenced in 1977, the relationship between FEL wavelength and output power, the high-power FEL driven by the superconducting linac, the X-ray FEL by the linac, and the medical use are described. FEL is the vacuum oscillator tube and essentially composed from the high-energy linac, undulator and light-resonator. It utilizes free electrons in the vacuum to generate the beam with wavelength ranging from microwave to gamma ray. The first high-power FEL developed in Japanese Atomic Energy Research Institute (JAERI) is based on the development of superconducting linac for oscillating the highest power beam. In the medical field, applications to excise brain tumors (in US) and to reconstruct experimentally blood vessels in the pig heart (in Gunma University) by lasing and laser coagulator are in progress with examinations to remove intra-vascular cholesterol mass by ...

2003-06-01

345

Predictive model of electron-beam-induced flashblindness. Final report, November 1983-October 1984  

Energy Technology Data Exchange (ETDEWEB)

The spectral characteristics of the Cherenkov radiation have been evaluated and converted to equivalent retinal irradiance from external sources. On the basis of the conversion, electron fluxes have been estimated for 2-sec recovery times from flashblindness. The electrons are assumed to have energies greater than 6 MeV and to be delivered in one or more bursts of 1 microsecond each over 1 sec. It is important to note that very little data exists on recovery times as short as 2 sec for either photopic and scotopic conditions. This situation is a direct result of the lack of definition of the critical tasks and their sensitivity to an interruption of background adaptation. The Cherenkov radiation produced within the eye by relativistic electrons can be compared to light from external sources by the relationships: 1 rad approx. = 4.6 scotopic td-sec and 1 rad approx. = 0.55 photopic td sec. Based on these ...

1985-03-01

346

Thermoluminescence emission of X-irradiated Eu{sup 2+} doped KBr single crystals  

Energy Technology Data Exchange (ETDEWEB)

In this paper we discuss the results of thermoluminescence (TL) studies carried out on freshly quenched crystals of KBr doped with {approx} 50 ppm of Eu{sup 2+} ions which were X-irradiated at room temperature. The TL glow curve of this phosphor material consists of three glow peaks at 355, 376 and 398 K whose intensities increased as a function of X-irradiation time. The TL glow peaks were analyzed by the total curve-fitting method in order to obtain the characteristic parameters; activation energy, pre-exponential factor and kinetic order. The spectral character of the emission recorded during thermoluminescence was found to be the same for all glow peaks and consists of a broad band centered at {approx} 420 nm. It is proposed that the model of the TL process most consistent with our experimental results is one in which the Eu{sup 2+} impurity acts as an electron trap during the irradiation process ...

1996-12-31

347

Thermoluminescence emission of X-irradiated Eu"2"+ doped KBr single crystals  

International Nuclear Information System (INIS)

In this paper we discuss the results of thermoluminescence (TL) studies carried out on freshly quenched crystals of KBr doped with #approx# 50 ppm of Eu"2"+ ions which were X-irradiated at room temperature. The TL glow curve of this phosphor material consists of three glow peaks at 355, 376 and 398 K whose intensities increased as a function of X-irradiation time. The TL glow peaks were analyzed by the total curve-fitting method in order to obtain the characteristic parameters; activation energy, pre-exponential factor and kinetic order. The spectral character of the emission recorded during thermoluminescence was found to be the same for all glow peaks and consists of a broad band centered at #approx# 420 nm. It is proposed that the model of the TL process most consistent with our experimental results is one in which the Eu"2"+ impurity acts as an electron trap during the irradiation process and that ...

348

Radiation hardening effects on localized deformation and stress corrosion cracking of stainless steels  

International Nuclear Information System (INIS)

Radiation hardening in austenitic stainless steels is shown to modify deformation characteristics and correlate well with an increased susceptibility to intergranular stress corrosion cracking (IGSCC). Available data on neutron-irradiated materials have been analyzed and correlations developed between fluence, yield strength and cracking susceptibility in high-temperature water environments. Large heat-to-heat differences in the critical fluence (0.2 to 2.5 x10"2"1 n/cm"2) for IGSCC are documented. In many cases, this variability is consistent with yield strength differences among irradiated materials. IGSCC correlates better to yield strength than to fluence for most heats suggesting a possible role of radiation-induced hardening and microstructure on cracking. Microstructural evolution during proton and heavy-ion irradiation has been characterized in low-carbon 304SSs. Hardening results from a dispersion of dislocation ...

1993-08-01

349

Microstructural analysis of as-processed U-10 wt.%Mo monolithic fuel plate in AA6061 matrix with Zr diffusion barrier  

International Nuclear Information System (INIS)

For higher U-loading in low-enriched U-10 wt.%Mo fuels, monolithic fuel plate clad in AA6061 is being developed as a part of Reduced Enrichment for Research and Test Reactor (RERTR) program. This paper reports the first characterization results from a monolithic U-10 wt.%Mo fuel plate with a Zr diffusion barrier that was fabricated as part of a plate fabrication campaign for irradiation testing in the Advanced Test Reactor (ATR). Both scanning and transmission electron microscopy (SEM and TEM) were employed for analysis. At the interface between the Zr barrier and U-10 wt.%Mo, going from Zr to U(Mo), UZr_2, #gamma#-UZr, Zr solid-solution and Mo_2Zr phases were observed. The interface between AA6061 cladding and Zr barrier plate consisted of four layers, going from Al to Zr, (Al, Si)_2Zr, (Al, Si)Zr_3 (Al, Si)_3Zr, and AlSi_4Zr_5. Irradiation behavior of these intermetallic phases is discussed based on their constituents. ...

2010-07-01

350

Irradiation damage in spinel ceramics MgAl_2O_4 and ZnAl_2O_4: application to the transmutation of the nuclear waste  

International Nuclear Information System (INIS)

The transmutation of minor actinides in-reactor is one solution currently being studied for the long time management of nuclear waste. In the heterogeneous concept the radionuclides are incorporating in an inert ceramic matrix. The support material must be insensitive to radiation damage. Fission product damage is the main radiation damage source during the transmutation process and therefore it is of the utmost importance to study their effects. We irradiated spinels MgAl_2O_4 (matrix of reference) and ZnAl_2O_4 by fast ions (by example: (86)Kr of approximately 400 MeV) simulating the fission products. Under these conditions, the damage is primarily due to the electronic energy losses (Se). One of the structural features of spinel AB_2O_4 is that the two cations (A(2+) and B(3+)) can exchange their site. This phenomenon is quantified by the inversion parameter. We highlight by XRD in grazing incidence that the structural changes observed in ...

351

Accelerators for proton and heavy ion radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

The construction of Heavy Ion Medical Accelerator in Chiba (HIMAC) at the National Institute of Radiological Sciences was completed in December 1993. HIMAC consists of an injector linac, two synchrotron rings, a high energy beam transport system and a beam irradiation system. Its accelerator parameters are based on the medical requirement, and helium, carbon, neon, silicon and argon were selected as the accelerated ion species. It has 3 therapy rooms (A{approx}C). Room A has a vertical irradiation system, Room C horizontal and Room B both vertical and horizontal. Two rings can supply beams independently to the vertical and horizontal irradiation systems. Clinical trial started on June 21 1994, after several basic biological and physics experiments lasting about 2 months. Cancer is the top cause of death in Japan since 1981, and people expect good treatment results at HIMAC. Proton and heavy ion radiotherapy has the ...

1995-03-01

352

Semi-empirical simulation of thermoluminescent response under different filter geometries; Simulacao semi-empirica da resposta termoluminescente sob diferentes geometrias de filtro  

Energy Technology Data Exchange (ETDEWEB)

Many thermoluminescent materials has been developed and used for photon personal dosimetry but no one has all desired characteristics alone. These characteristics include robustness, high sensitivity, energy photon independence, large range of photon energy detection, good reproducibility, small fading and simple glow curve with peaks above 150 deg C. Calcium Sulfate Dysprosium doped (CaSO{sub 4}:Dy) phosphor Thermoluminescent Dosimeter (TLD) has been used by many laboratories, mainly in Brazil and India. Another interesting phosphor is Calcium Fluoride (CaF{sub 2}). These phosphor advantages begin to be more required and its disadvantages have became more apparent, in a global market more and more competitive. These phosphors are used in environmental and area monitoring, once they present more sensibility than other phosphors, like LiF:Mg. Theirs mainly disadvantage is a strong energetic dependence response, which must be corrected for theirs application in the field, where photon ...

2006-07-01

353

Investigation of acoustic waves generated in an elastic solid by a pulsed ion beam and their application in a FIB based scanning ion acoustic microscope  

International Nuclear Information System (INIS)

The aim of this work is to investigate the acoustic wave generation by pulsed and periodically modulated ion beams in different solid materials depending on the beam parameters and to demonstrate the possibility to apply an intensity modulated focused ion beam (FIB) for acoustic emission and for nondestructive investigation of the internal structure of materials on a microscopic scale. The combination of a FIB and an ultrasound microscope in one device can provide the opportunity of nondestructive investigation, production and modification of micro- and nanostructures simultaneously. This work consists of the two main experimental parts. In the first part the process of elastic wave generation during the irradiation of metallic samples by a pulsed beam of energetic ions was investigated in an energy range from 1.5 to 10 MeV and pulse durations of 0.5-5 #mu#s, applying ions with different masses, e.g. oxygen, silicon and gold, in charge states from 1"+ to 4"+. The ...

354

ANALYSIS OF ACCELERATOR BASED NEUTRON SPECTRA FOR BNCT USING PROTON RECOIL SPECTROSCOPY  

Energy Technology Data Exchange (ETDEWEB)

Boron Neutron Capture Therapy (BNCT) is a promising binary treatment modality for high-grade primary brain tumors (glioblastoma multiforme, GM) and other cancers. BNCT employs a boron-10 containing compound that preferentially accumulates in the cancer cells in the brain. Upon neutron capture by {sup 10}B energetic alpha particles and triton released at the absorption site kill the cancer cell. In order to gain penetration depth in the brain Fairchild proposed, for this purpose, the use of energetic epithermal neutrons at about 10 keV. Phase I/II clinical trials of BNCT for GM are underway at the Brookhaven Medical Research Reactor (BMRR) and at the MIT Reactor, using these nuclear reactors as the source for epithermal neutrons. In light of the limitations of new reactor installations, e.g. cost, safety and licensing, and limited capability for modulating the reactor based neutron beam energy spectra alternative neutron sources are being contemplated for wider ...

1998-11-06

355

Status of the WAND (Waste Assay for Nonradioactive Disposal) project as of July 1997  

Energy Technology Data Exchange (ETDEWEB)

The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole system and to perform the data analysis. WAND system minimum detectable activities (MDAs) for point sources ...

1998-03-01

356

Si and Si/P implants in In{sub 0.5}Ga{sub 0.5}P and In{sub 0.5}Al{sub 0.5}P  

Science.gov (United States)

Si and Si/P ion implantation doping of In{sub 0.5}Ga{sub 0.5}P and In{sub 0.5}Al{sub 0.5}P has been studied for several Si and P doses at energies of 90 and 100 keV, respectively. For single Si implants in InGaP a maximum Hall sheet electron concentration of 1.33{times}10{sup 13} cm{sup {minus}2} is achieved for a Si dose of 5{times}10{sup 13} cm{sup {minus}2}. When an optimum dose (2.5{times}10{sup 13} cm{sup {minus}2}) P coimplant is performed this electron concentration is increased by 65{percent}. The same dose Si implants in InAlP show a maximum effective activation of 3.9{percent} with no P coimplantation and 5.2{percent} with a P-implant dose 1.5 times the silicon dose. The apparent donor ionization energies are estimated from variable temperature Hall measurements to be 2{endash}5 meV for InGaP and {approximately}80 meV for InAlP. The deeper level in InAlP is attributed to the DX level found in the Al-containing ...

1996-06-01

357

Reevaluation of 58Ni and 60Ni Resonance Parameters in the Energy Range Thermal to 800 keV  

Energy Technology Data Exchange (ETDEWEB)

The previous 58Ni and 60Ni set of resonance parameters (ENDF/B-VII-0, JEFF-3, etc.) was based on the SAMMY analysis of Oak Ridge National Laboratory neutron transmission, scattering cross section and capture cross section measurements by C. M. Perey et al. The present results were obtained by adding to the SAMMY experimental data base the capture cross sections measured recently at the Oak Ridge Linear Electron Accelerator by Guber et al. and the Geel Electron Linear Accelerator very high-resolution neutron transmission measurements performed by Brusegan et al. A complete resonance parameter covariance matrix (RPCM) was obtained from the SAMMY analysis of the experimental database. The data sets were made consistent, when needed, by adjusting the neutron energy scales, the normalization coefficients, and the background corrections. The RPCM allows the calculation of the cross section uncertainties due mainly to statistical errors in the ...

2009-09-01

358

Re-evaluation of {sup 58}Ni and {sup 60}Ni resonance parameters in the neutron energy range thermal to 800 keV  

Energy Technology Data Exchange (ETDEWEB)

The previous {sup 58}Ni and {sup 60}Ni set of resonance parameters (Endf/B7.O, Jeff-3, etc.) was based on the SAMMY analysis of Oak Ridge National Laboratory neutron transmission, scattering cross section and capture cross section measurements by C.M. Perey et al. The present results were obtained by adding to the SAMMY experimental database the capture cross sections measured recently at the Oak Ridge Linear Electron Accelerator by Guber et al. and the Geel Electron Linear Accelerator and very high-resolution neutron transmission measurements performed by Brusegan et al. A complete resonance parameter covariance matrix (RPCM) was obtained from the SAMMY analysis of the experimental database. The data sets were made consistent, when needed, by adjusting the neutron energy scales, the normalization coefficients, and the background corrections. The RPCM allows the calculation of the cross section uncertainties due mainly to statistical errors in ...

2009-07-01

359

Initiation of ecton processes by interaction of a plasma with a microprotrusion on a metal surface  

International Nuclear Information System (INIS)

Evolution of rapid (?10 ns) Ohmic overheating of a microprotrusion on a surface in contact with a plasma by emission current is studied taking into account the energy carried by plasma ions and electrons, as well as Ohmic heating, emissive source of energy release (Nottingham effect), and heat removal due to heat conduction. Plasma parameters were considered in the range of n = 1014-1020 cm-3 and Te = 0.1 eV-10 keV. The threshold value of energy transferred to the surface from the plasma is found to be 200 MW/cm2; above this value, heating becomes explosive (namely, an increase in the temperature growth rate (?2T/?t2 > 0) and in passing current (?J/?t > 0) is observed in the final stage at T ? 104 K and j ? 108 A/cm2). In spite of the fact that Ohmic heating does not play any significant role for plasmas with a density lower than 10 18 cm-3 because the current is limited by the space charge of electrons, rapid ...

2008-12-01

360

Effect of nitrogen segregation on TED and loss of phosphorus in CZ-Si  

Energy Technology Data Exchange (ETDEWEB)

Transient enhanced diffusion (TED) and dose loss (pile-up) are investigated for phosphorus-implanted samples covered with both oxide and nitride films. P ions were implanted into p-type (1 0 0) CZ-Si (dose 5x10{sup 13} cm{sup -3}, 100 keV) through a chemical vapor deposition (CVD) Si{sub 3}N{sub 4} film. For a half of samples, Si{sub 3}N{sub 4} was etched off and SiO{sub 2} films were grown by CVD. Both samples were annealed for 20-360 min at 700 deg. C. Diffusivity of P and the dose loss were estimated based on the secondary-ion mass spectrometry (SIMS) P profiles. Both Si/Si{sub 3}N{sub 4} and Si/SiO{sub 2} interfaces were investigated with transmission electron microscopy (TEM) and electron energy-loss spectroscopy (EELS). There is no significant difference in P diffusivity between the SiO{sub 2} and Si{sub 3}N{sub 4} films for the present annealing condition of 700 deg. C for 20-360 min. Regarding dose loss, a distinct ...

2002-01-01

361

Effect of nitrogen segregation on TED and loss of phosphorus in CZ-Si  

International Nuclear Information System (INIS)

Transient enhanced diffusion (TED) and dose loss (pile-up) are investigated for phosphorus-implanted samples covered with both oxide and nitride films. P ions were implanted into p-type (1 0 0) CZ-Si (dose 5x10"1"3 cm"-"3, 100 keV) through a chemical vapor deposition (CVD) Si_3N_4 film. For a half of samples, Si_3N_4 was etched off and SiO_2 films were grown by CVD. Both samples were annealed for 20-360 min at 700 deg. C. Diffusivity of P and the dose loss were estimated based on the secondary-ion mass spectrometry (SIMS) P profiles. Both Si/Si_3N_4 and Si/SiO_2 interfaces were investigated with transmission electron microscopy (TEM) and electron energy-loss spectroscopy (EELS). There is no significant difference in P diffusivity between the SiO_2 and Si_3N_4 films for the present annealing condition of 700 deg. C for 20-360 min. Regarding dose loss, a distinct different behavior was observed. In case of the SiO_2 cover ...

2002-01-01

362

A revised dosimetric model of the adult head and brain  

Energy Technology Data Exchange (ETDEWEB)

During the last decade, new radiopharmaceutical have been introduced for brain imaging. The marked differences of these tracers in tissue specificity within the brain and their increasing use for diagnostic studies support the need for a more anthropomorphic model of the human brain and head. Brain and head models developed in the past have been only simplistic representations of this anatomic region. For example, the brain within the phantom of MIRD Pamphlet No. 5 Revised is modeled simply as a single ellipsoid of tissue With no differentiation of its internal structures. To address this need, the MIRD Committee established a Task Group in 1992 to construct a more detailed brain model to include the cerebral cortex, the white matter, the cerebellum, the thalamus, the caudate nucleus, the lentiform nucleus, the cerebral spinal fluid, the lateral ventricles, and the third ventricle. This brain model has been included within a slightly modified version of the head model developed by ...

1996-06-01

363

A revised dosimetric model of the adult head and brain  

International Nuclear Information System (INIS)

During the last decade, new radiopharmaceutical have been introduced for brain imaging. The marked differences of these tracers in tissue specificity within the brain and their increasing use for diagnostic studies support the need for a more anthropomorphic model of the human brain and head. Brain and head models developed in the past have been only simplistic representations of this anatomic region. For example, the brain within the phantom of MIRD Pamphlet No. 5 Revised is modeled simply as a single ellipsoid of tissue With no differentiation of its internal structures. To address this need, the MIRD Committee established a Task Group in 1992 to construct a more detailed brain model to include the cerebral cortex, the white matter, the cerebellum, the thalamus, the caudate nucleus, the lentiform nucleus, the cerebral spinal fluid, the lateral ventricles, and the third ventricle. This brain model has been included within a slightly modified version of the head model developed by ...

1996-07-21

364

Surface morphology of thin lysozyme films produced by matrix-assisted pulsed laser evaporation (MAPLE)  

Energy Technology Data Exchange (ETDEWEB)

Thin films of the protein, lysozyme, have been deposited by the matrix-assisted pulsed laser evaporation (MAPLE) technique. Frozen targets of 0.3-1.0 wt.% lysozyme dissolved in ultrapure water were irradiated by laser light at 355 nm with a fluence of 2 J/cm{sup 2}. The surface quality of the thin lysozyme films of different thickness deposited on 7 mm x 7 mm Si-<1 0 0>-wafers was investigated with scanning electron microscopy and atomic force microscopy. Already at comparatively low thickness, {approx}20 nm, the substrate is covered by intact lysozyme molecules and fragments. The concentration of lysozyme in the ice matrix apparently does not play any significant role for the morphology of the film. The morphology obtained with MAPLE has been compared with results for direct laser irradiation of a pressed lysozyme sample (i.e. pulsed laser deposition (PLD))

2007-12-15

365

Proton exchange membranes prepared by grafting of styrene/divinylbenzene into crosslinked PTFE membranes  

International Nuclear Information System (INIS)

Thin PTFE membranes were prepared by coating the PTFE dispersion onto the aluminum films. Thus the thin crosslinked PTFE (RX-PTFE) membranes were obtained by means of electron beam irradiation above the melting temperature of PTFE under oxygen-free atmosphere. The RX-PTFE membranes were pre-irradiated and grafted by styrene with or without divinylbenzene (DVB) in liquid phase. The existence of DVB accelerated the initial grafting rate. The styrene grafted RX-PTFE membranes are white colored, on the other hand, the styrene/DVB grafted RX-PTFE membranes are colorless. The proton exchange membranes (PEMs) were obtained by sulfonating the grafted membranes using chlorosulfonic acid. The ion exchange capacity (IEC) values of the PEMs ranging from 1.5 to 2.8 meq/g were obtained. The PEMs made from the styrene/DVB grafted membranes showed higher chemical stability than those of the styrene grafted membranes under oxidative ...

2005-07-01

366

Characterization of spent fuel approved testing material: ATM-103  

Energy Technology Data Exchange (ETDEWEB)

The characterization data obtained to date are described for Approved Testing Material (ATM)-103, which is spent fuel from Assembly D101 of pressurized-water reactor Calvert Cliffs, No. 1. This report is one in a series being written by the Materials Characterization Center (MCC) at Pacific Northwest Laboratory (PNL) on spent fuel ATMs. The ATMs are receiving extensive examinations to provide a source of well-characterized spent fuel for testing in the US nuclear waste repository program. ATM-103 consists of 176 full-length irradiated fuel rods with rod-average burnups of about 2600 GJ/kgM (30 MWd/kgM) and less than 1% fission gas release. Characterization data include 1) as-fabricated fuel design, irradiation history, and subsequent storage and handling; 2) isotopic gamma scans; 3) fission gas analyses; 4) ceramography of the fuel and metallography of the cladding; 5) special fuels studies involving analytical transmission ...

1988-04-01

367

Characterization of spent fuel approved testing material---ATM-105  

Energy Technology Data Exchange (ETDEWEB)

The characterization data obtained to data are described for Approved Testing Material 105 (ATM-105), which is spent fuel from Bundles CZ346 and CZ348 of the Cooper Nuclear Power Plant, a boiling-water reactor. This report is one in a series being prepared by the Materials Characterization Center at Pacific Northwest Laboratory (PNL) on spent fuel ATMs. The ATMs are receiving extensive examinations to provide a source of well-characterized spent fuel for testing in the US Department of Energy Office of Civilian Radioactive Waste Management (OCRWM) Program. ATM-105 consists of 88 full-length irradiated fuel rods with rod-average burnups of about 2400 GJ/kgM (28 MWd/kgM) and expected fission gas release of about 1%. Characterization data include (1) descriptions of as-fabricated fuel design, irradiation history, and subsequent storage and handling; (2) isotopic gamma scans; (3) fission gas analyses; (4) ceramography of the fuel and metallography ...

1991-12-01

368

Total skin electron beam therapy for cutaneous lymphomas and leukemias  

International Nuclear Information System (INIS)

Total skin electron beam therapy (TSEB) was used in the treatment of 33 patients with lymphoma and 13 patients with leukemia involving extensive segments of the skin surface. Twenty-two of 23 had lesions as a primary manifestation of lymphoma (primary cutaneous lymphoma-PCL) and 11 developed cutaneous lesions following disseminated nodal lymphoma (secondary cutaneous lymphoma-SCL). A once weekly fractionation scheme was employed to irradiate the entire skin surface with 3.5 to 4 MeV electron beam from a 6 MeV linear accelerator. During each weekly session, 400 rad were delivered to the entire skin and a complete course consisted of 4-6 consecutive weekly sessions. The majority of patients have been previously treated elsewhere for various periods and all patients have been at risk for a median of 12 months, range from 12-117 months following TSEB. Striking predominance of the diffuse pattern (76%) was demonstrated in both ...

369

Synthesis of polyester styrene resin beads as polymeric ionic exchangers by using chemical and irradiation techniques  

International Nuclear Information System (INIS)

The aim of the study is to prepare ionic exchangers using the polymerization of unsaturated polyster with monomeric styrene units in a ratio of 60%: 40% respectively. The type of method involved in this preparation, is called An Emulsion Polymerization. Such type of polymerization was carried out by two techniques: chemical and irradiation techniques. The first techniques requires the formation of free radical monomers by use of methyl Ethy Ketone Peroxide capable of decomposing into free radicals upon heating, while the other technique involves the use of gamma rays (using Co-60 source) capable of activating monomers towards free radical formations. A number of very effective chemical parameters and physical factors were used and investigated throughout the reactions such as: dispersant matrix, viscosity, rate of mixing, and irradiation dose. Besides, the study has included the study of the rate of Resin Beads Swelling which is thought to be ...

3087-01-01

370

Dosimetry for Total Skin Electron Beam Therapy in Skin Cancer  

International Nuclear Information System (INIS)

Increasing frequency of skin cancer, mycosis fungoides, Kaposi sarcoma etc, it need to treatment dose planning for total skin electron beam (TSEB) therapy. Appropriate treatment planning for TSEB therapy is needed to give homogeneous dose distribution throughout the entire skin surface. The energy of 6 MeV electron from the 18 MeV medical linear accelerator was adapted for superficial total skin electron beam therapy. The energy of the electron beam was reduced to 4.2 MeV by a 0.5cmx90cmx180cm acryl screen placed in a feet front of the patient. Six dual field beam was adapted for total skin irradiation to encompass the entire body surface from head to toe simultaneously. The patients were treated behind the acryl screen plate acted as a beam scatterer and contained a parallel-plate shallow ion chamber for dosimetry and beam monitoring. During treatment, the patient was placed in six ...

1992-06-01

371

Thermo-transferred thermoluminescence (TTTl) in potassium-yttrium double fluoride doped with terbium  

International Nuclear Information System (INIS)

This paper presents results of studying the thermo-transferred thermoluminescence (TTTl) phenomenon in potassium-yttrium double fluoride doped with terbium (K_2YF_5_:Tb) at different impurity concentrations (0.8%, 0.95% and 0.99%). Previously to study the TTTl phenomenon, structural characterization and chemical composition of the materials were determined. The structural studies were conducted using a scanning electron microscope; meanwhile, chemical composition was analyzed using energy dispersive X-ray spectroscopy. Thermoluminescence kinetics was studied irradiating the samples with "1"3"7Cs gamma rays as well as with "9"0Sr/"9"0Y beta rays, analyzing the glow curves by the deconvolution method for obtaining the kinetic parameters. (Author)

2011-02-01

372

Radiosterilization of drugs in aqueous solutions may be achieved by the use of radioprotective excipients  

British Library Electronic Table of Contents (United Kingdom)

The aim of this study was to assess the feasibility of radiosterilization of drugs aqueous solutions and to evaluate the effects of some additives, such as mannitol, nicotinamide and pyridoxine, which might protect the drug from degradation. Metoclopramide was selected as a model drug. The structures of the degradation products were determined to gain insight on the radiolysis mechanisms in aqueous solution in order to design strategies to lower the drug degradation.Metoclopramide hydrochloride aqueous solutions with and without excipients were irradiated either with gamma rays or high-energy electrons. HPLC-DAD was used to measure the loss of chemical potency and to quantify the degradation products which were also characterized by LC-APCI-MS-MS. Metoclopramide recovery for gamma and elec...

2008-01-01

373

Ion-induced phase formation in metal-silicon systems. [Xenon ion implantation effects  

Energy Technology Data Exchange (ETDEWEB)

By using megaelectronvolt /sup 4/He ion backscattering techniques and transmission electron microscopy, the authors have investigated the interactions of ion beams with thin film structures in a number of silicide-forming systems. The mixed layer was found to be an equilibrium compound for near-noble metals and an amorphous phase for refractory metals. Differences in behavior have also been observed in near-noble metal systems. For palladium, the Pd/sub 2/Si phase grew with ion dose and remained crystalline up to high dose. For nickel, the compound Ni/sub 2/Si was formed initially and became amorphous on prolonged irradiation. All the results indicate the significance of atomic mobility at target temperatures in determining the phase formation and in explaining the sensitivity of the silicides to ion bombardment.

1985-01-11

374

Ion-induced phase formation in metal-silicon systems  

International Nuclear Information System (INIS)

By using megaelectronvolt "4He ion backscattering techniques and transmission electron microscopy, the authors have investigated the interactions of ion beams with thin film structures in a number of silicide-forming systems. The mixed layer was found to be an equilibrium compound for near-noble metals and an amorphous phase for refractory metals. Differences in behavior have also been observed in near-noble metal systems. For palladium, the Pd_2Si phase grew with ion dose and remained crystalline up to high dose. For nickel, the compound Ni_2Si was formed initially and became amorphous on prolonged irradiation. All the results indicate the significance of atomic mobility at target temperatures in determining the phase formation and in explaining the sensitivity of the silicides to ion bombardment. (Auth.).

375

Identity and yield of positive charge centers in irradiated chloro hydrocarbon liquids and the rates of their interaction with solute molecules. [3-4 MeV electrons  

Science.gov (United States)

Pulse radiolysis studies of the formation kinetics and the yields of various phenylcarbenium ions from several different solutes in 1,2-dichloroethane solution have been carried out. The results indicate that there are two kinetically distinguishable cationic species of the solvent which react selectively with the different solutes to form the phenylcarbenium ions. It is suggested that one is a cation radical (yield 0.68 molecule/100 eV) and the other a carbocation (yield 0.20 molecule/100 eV). Rate constants for their separate reactions with selected aromatic compounds and with ammonia have been determined. Molar extinction coefficients have been estimated for benzyl cation, diphenyl cation radical, and anthracene cation radical. 6 figures, 1 table.

1979-07-26

376

Formation of metal-polymer hybrid nanostructures during radiation-induced reduction of metal ions in poly(acrylic acid)-poly(ethylenimine) complexes  

British Library Electronic Table of Contents (United Kingdom)

The formation of nanoparticles during the radiation-induced chemical reduction of silver ions, copper ions, and nickel ions in films based on poly(acrylic acid)-poly(ethylenimine) complexes are studied via electron microscopy. This approach allows preparation of composites containing nanoparticles that are randomly distributed in the polymer matrix and materials with a regular spatial distribution of nanoparticles across the film thickness and in subsurface layers. The structure of metal-polymer hybrid materials is dependent on the irradiation conditions, the type of reduced metal ions, and their initial content in polymer matrices. The ratio between the rate of nucleation and the rate of growth of nanoparticles in the matrices of interpolyelectrolyte complexes depends on the intensity of ...

2011-01-01

377

Depth-profiling of vertical sidewall nanolayers on structured wafers by grazing incidence X-ray flourescence  

British Library Electronic Table of Contents (United Kingdom)

The Physikalisch-Technische Bundesanstalt (PTB), Germany's national metrology institute, developed an alignment strategy to specify elemental depth profiling in vertical sidewall layers on structured wafers. For this purpose, PTB's irradiation chamber for 200?mm and 300?mm silicon wafers was used to combine total-reflection X-ray fluorescence (TXRF) and grazing incidence XRF (GIXRF) techniques by employing monochromatized undulator radiation of the BESSY II electron storage ring. 3-D test structures were fabricated to develop an optimal alignment strategy allowing for depth profiling in such nanolayers. The test structures consisted of silicon bars with widths/spacings either in the ?m or in the nm range. In order to be able to differentiate the sidewalls more easily from the remainder of ...

2008-01-01

378

Review of the microscopic cross sections for the americium isotopes in the resolved resonance region. [0. 5 eV to 10 keV  

Science.gov (United States)

The differential cross section measurements for /sup 241/Am, /sup 242m/Am and /sup 243/Am are reviewed in the energy range from 0.5 eV to 10 keV. Parameters extracted from resonance analysis, such as the neutron strength function, the average level spacing, the average capture and fission widths, are compared for the various measurements. The average capture and fission cross sections from 100 eV to 10 keV are directly compared. The status of the data set is discussed with suggestions for further measurements. 24 references.

1978-11-16

379

Direct Comparison of the X-Ray Emission and Absorption of Cerium Oxide  

Energy Technology Data Exchange (ETDEWEB)

Bremstrahlung Isochromat Spectroscopy (BIS). The XES spectra were collected using a Specs electron gun for the excitation and the XES 350 grating monochromator and channel plate system from Scienta as the photon detection. Spectra were collected in 'normal mode,' where the electron gun kinetic energy (KE) and the energy position of the center of the channel plate were both fixed and the energy distribution in the photon (hv) spectrum was derived from the intensities distributed across the channel plate detector in the energy dispersal direction. The polycrystalline Ce sample was oxidized by exposure to air at ambient pressures. After introduction to the ultra-high vacuum system, the oxidized sample was bombarded with Ar, to clean the topmost surface region and stabilize the surface and near surface regions. Although CeO{sub 2} would be the thermodynamically preferred composition in an oxygen rich environment, the combination ...

2010-11-24

380

Review of JT-60U experimental results from February to October, 1999  

International Nuclear Information System (INIS)

In 1999, the plasma parameters of reversed shear (RS) plasmas had been extended in 1) DT-equivalent fusion power gain Q_D_T"e"q - 0.5 (n_D(0)#tau#_ET_i(0) - 4x10"2"0 m"-"3#centre dot#keV#centre dot#s) for 0.8 s and 2) full non-inductive current drive with 80% of the bootstrap current fraction. Physics of the internal transport barriers (ITBs) in RS plasmas, including the energy transport and the formation of ITB, were extensively studied. A nearly full current drive (92% non-inductively) was obtained with negative ion based neutral beam (NNB) injection (360 keV, 3.4 MW) in a high #beta#_p H-mode plasma (I_p=1.5 MA, B_T=3.7 T, q_9_5=4.2) with high plasma performance (#beta#_N=2.4 and H_8_9=2.56). Rise in the central electron temperature (T_e - 9 keV) resulted in the current drive efficiency #eta#_C_D of NNB reached 1.3x10"1"9 A/W/m"2, the highest for the neutral beam current drive. As for the H-mode plasmas, decrease in the ...

1994-06-01

381

The investigations on K and L X-ray fluorescence parameters of gold compounds  

British Library Electronic Table of Contents (United Kingdom)

The study aimed to determine the chemical effects on the K and L X-ray intensity ratios and the K and L X-ray production cross sections for gold compounds. The K shell fluorescence yields and L shell average yields were also investigated. The samples were excited by 59.5keV ?-rays from an 241Am annular radioactive source and 123.6keV ?-rays from a 57Co annular radioactive source. K and L X-rays emitted from samples were counted by an Ultra-LEGe detector with a resolution of 0.150keV at 5.9keV. The experimental values were compared with theoretical, the semi-empirical and other experimental values.

2010-01-01

382

The Canonical Seyfert Spectrum: The Implications of OSSE ...  

Science.gov (United States)

... In a HEAO 1 study of active galaxies, principally Seyfert 1s, in the 2, 165 keV energy range, Rothschild et al. ... As discussed by Rothschild et al. ...

2011-05-14

383

On penetration effect in M1 component of 70.45 keV #gamma#-transition in "1"7"7Ta  

International Nuclear Information System (INIS)

... gamma radiation l conversion m conversion mev range 10-100 mixing ratio

1987-04-14

384

Electric and magnetic dipole transitions in odd-proton rare-earth nuclei  

International Nuclear Information System (INIS)

... gamma cascades kev range 10-100 lifetime lutetium 171 lutetium 173 lutetium

1972-05-01

395

A deterministic partial differential equation model for dose calculation in electron radiotherapy  

International Nuclear Information System (INIS)

High-energy ionizing radiation is a prominent modality for the treatment of many cancers. The approaches to electron dose calculation can be categorized into semi-empirical models (e.g. Fermi-Eyges, convolution-superposition) and probabilistic methods (e.g. Monte Carlo). A third approach to dose calculation has only recently attracted attention in the medical physics community. This approach is based on the deterministic kinetic equations of radiative transfer. We derive a macroscopic partial differential equation model for electron transport in tissue. This model involves an angular closure in the phase space. It is exact for the free streaming and the isotropic regime. We solve it numerically by a newly developed HLLC scheme based on Berthon et al (2007 J. Sci. Comput. 31 347-89) that exactly preserves the key properties of the analytical solution on the discrete level. We discuss several test cases taken from the medical physics literature. ...

2010-07-07

396

Relationship between the density of states and the superconducting transition temperature in A-15 compounds  

International Nuclear Information System (INIS)

Data by Wiesmann et al. on the temperature coefficient of the upper critical field, dH/sub c/2(T)/dT, and the normal-state resistivity rho_0 near the superconducting transition temperature T/sub c/ are analyzed to estimate the bare density of states N (E/sub F/) as a function of structural disorder and T/sub c/ in various #alpha#-particle irradiated samples of A-15 Nb_3Ge and Nb_3Sn. By taking into account the change in the electron-phonon coupling strength with T/sub c/ and the effect of mass enhancement arising from the electron-phonon interaction, the results of the new analysis indicate that (i) the drop in N (E/sub F/) for Nb_3Ge is relatively small as T/sub c/ changes from approx. 21 to approx. 4 K, in agreement with a recent low-temperature specific-heat measurement; (ii) the value of N (E/sub F/) in Nb_3Sn decreases by a factor of approx. 4 as T/sub c/ varies from approx. 18 to approx. 3 K. The implication of these ...

397

Free electron laser and superconductivity  

International Nuclear Information System (INIS)

The lasing of the first free-electron laser (FEL) in the world was successfully carried out in 1977, so the history of FELs as a light source is not so long. But FELs are now utilized for research in many scientific and engineering fields owing to such characteristics as tunability of the wavelength, and short pulse and high peak power, which is difficult utilizing a common light source. Research for industrial applications has also been carried out in some fields, such as life sciences, semiconductors, nano-scale measurement, and others. The task for the industrial use of FEL is the realization of high energy efficiency and high optical power. As a means of promoting realization, the combining of an FEL and superconducting linac is now under development in order to overcome the thermal limitations of normal-conducting linacs. Further, since tuning the wavelength is carried out by changing the magnetic density of the undulator, which is now induced by moving part ...

2003-07-01

398

Electron beam therapy in squamous and basal cell carcinoma of the face. L'electrontherapie des epitheliomas cutanes de la face  

Energy Technology Data Exchange (ETDEWEB)

This work is a retrospective study of 86 patients with squamous cell (51) and basal cell (35) carcinoma of the face. The median age was 67 years. The staging is as following: 31 cases T{sub 1} and T{sub 2}, 55 patients T{sub 3} and T{sub 4}. All patients were considered NO. Electron beam was used in all cases and energy ranged from 5 to 15 MeV depending on the thickness of the tumor. The total tumor dose was 60-70 Gy delivered in 6 weeks. In 7 cases of very old patients the authors have used concentrated irradiation: 3 patients received 21 Gy in one fraction and 4 patients 48 Gy in 8 fractions. 96.8% patients T{sub 1} i T{sub 2} are NED contrary to 56.4% T{sub 3} i T{sub 4}. Cosmetic results were considered as good in 52, fairly good in 7 and bad in 2 patients.

1989-01-01

399

Electron beam processing of rubber wood fibers - polypropylene composites. Effects of reactive additives on the physical and mechanical properties  

International Nuclear Information System (INIS)

The purpose of this study is to determine the suitability of producing agro-fiber reinforced plastic composite (agro-FRPC) from rubber wood fiber blended in polypropylene matrix. The effects of varying fiber dimension and fiber content on the physical and mechanical properties of the composite were evaluated to provide an insight into the fiber matrix adhesion. The effects of reactive additives on the physical and mechanical properties of the composite were evaluated which provides the insight on the reinforcement of the composite. Rubber wood fiber used in this study is currently being used in the manufacturing of medium density fiber (MDF) board. Two sizes of rubber wood fiber were used i.e. 0.5-1.0 mm and 1.0-2.0 mm. Homopolymer polypropylene of MFI 14.0 was used as a matrix. The irradiation work was carried out using electron beam accelerator, 3.0 MeV, 3.0 mA. Various types of reactive additives (RA) with mono-functional, di-functional, ...

2000-03-13

400

Structure of Irradiated Materials  

International Science & Technology Center (ISTC)

Fundamental Research of Materials Structure and Properties Changes Resulted from Irradiation by Means of Complex of Modern Physical Methods

401

Isolation of carrier-free tantalum radioisotopes from proton-irradiated hafnium  

International Nuclear Information System (INIS)

... carrier-free isotopes hafnium compounds irradiation protons solvent extraction

403

Intercomparison of irradiance measurements based on WRR and ETL irradiance scales  

Energy Technology Data Exchange (ETDEWEB)

We report the corrected intercomparison of the World Radiometer Reference (WRR) irradiance scale and the Electrotechnical Laboratory (ETL) spectral irradiance scale. In addition, we confirm the intercomparison precision using the test facility where the irradiance of ETL 500 W standard lamp can be measured directly with the cavity radiometer. The results showed that the irradiance based on the WRR scale was 0.5-0.7% lower than the one based on the ETL scale

1997-10-14

404

Effects of helium/DPA ratio, alloy composition and cold work on microstructural evolution and hardening of "5"9Ni-doped Fe-Cr-Ni alloys neutron-irradiated at 465 C  

International Nuclear Information System (INIS)

Three ternary austenitic alloys (Fe-15Cr-25Ni, Fe-15Cr-25Ni-0.04P, Fe-15Cr-45Ni in both annealed and cold worked conditions) were irradiated at 465 C to 0.15, 0.28, and 0.42 dpa at above core position in the Fast Flux Test Facility utilizing the Materials Open Test Assembly to study the separate and synergistic effects of He/dpa ratio, phosphorus addition, nickel content and cold work level on microstructural evolution and hardening. The helium/dpa ratio was varied by isotopic doping with "5"9Ni to enhance the production rate of helium. The helium production rate was evaluated to be 62 appm He/dpa in the "5"9Ni-doped specimens and 0.26 appm He/dpa in the undoped specimens. Transmission electron microscopic examinations revealed that alloy composition affected significantly the evolution of microstructure during irradiation. Phosphorus addition prevented the formation of Frank loops through the precipitation of phosphide. ...

1994-06-20

405

ESR study of the aziridine and azetidine radical cations: evidence for the C...C ring-opened aziridine radical cation  

International Nuclear Information System (INIS)

The radical cations from aziridine and azetidine have been characterized by ESR spectroscopy following their generation in the solid state by #gamma# irradiation of dilute solutions of the parent compounds in the CFCl_3 matrix at 77 K. The ESR parameters of the azetidine radical cation are typical of those for nitrogen-centered amine radical cations such as Me_2NH*"+. On the other hand, the radical cation formed from aziridine has very different ESR parameters that compare closely to those for the isoelectronic C...C ring-opened form of the oxirane radical cation and the allyl radical. The radical cation formed from azetidine is therefore assigned a ring-closed structure with the unpaired electron in a 2p/sub z/ orbital on nitrogen perpendicular to the ring plane, whereas the cation from aziridine is an allylic C...C ring-opened planar isomer with the unpaired electron in a nonbonding #pi# orbital centered mainly on the two ...

406

ESR study of the aziridine and azetidine radical cations: evidence for the C. C ring-opened aziridine radical cation  

Energy Technology Data Exchange (ETDEWEB)

The radical cations from aziridine and azetidine have been characterized by ESR spectroscopy following their generation in the solid state by ..gamma.. irradiation of dilute solutions of the parent compounds in the CFCl/sub 3/ matrix at 77 K. The ESR parameters of the azetidine radical cation are typical of those for nitrogen-centered amine radical cations such as Me/sub 2/NH*/sup +/. On the other hand, the radical cation formed from aziridine has very different ESR parameters that compare closely to those for the isoelectronic C...C ring-opened form of the oxirane radical cation and the allyl radical. The radical cation formed from azetidine is therefore assigned a ring-closed structure with the unpaired electron in a 2p/sub z/ orbital on nitrogen perpendicular to the ring plane, whereas the cation from aziridine is an allylic C...C ring-opened planar isomer with the unpaired electron in a nonbonding ..pi.. orbital ...

1986-05-22

407

Accelerator technology program. Progress report, April-December 1978  

Science.gov (United States)

This report presents highlights of activities in the Acceleartor Technology (AT) Division from April through December 1978. The report is divided into 10 sections to cover work done by the four groups that make up AT Division (AT-1, AT-2, AT-3, and AT-4). Section I is a brief summary of the whole report. Sections II through VI describe work done by At-1, the Linac Technology Group. Subjects covered are the Pion Generation for Medical Irradiation Program, the Electronuclear Fuel-Producing Accelerator Program, the Gyrocon rf Amplifier Program, the Electron Linear Accelerator Program, and the Free Electron Laser Program. Section VII covers the Linear Accelerator Beam Dynamics development, and Sec. VIII deals with work with the H/sup -/ Ion Source. Most of the work in Secs. VII and VIII was done by AT-2, the Special Projects Group, although work on factors influencing emittance growth was done by MP-9, and results on emittance ...

1980-05-01

408

Dynamics of a very intense pulsed electron beam  

Energy Technology Data Exchange (ETDEWEB)

A unique beam of pulsed electrons has been developed using the 19-MeV, 700-kA Hermes-III accelerator. The extended planar-anode diode is used to extract at large radius an annular electron beam from the accelerator and inject the resulting beam at small angle into a low-pressure gas cell, where the beam is rapidly charge neutralized and almost current neutralized. Under these conditions, the beam propagates nearly ballistically to a focus downstream of injection, where objects can be placed for irradiation and study. For a focal length of 78 cm, measurements with a segmented calorimeter show that this configuration can deliver an energy deposition of 200 J/g [20 Mrad] over a useful area of 70 cm{sup 2} and a 4-cm depth in graphite in 25 ns. Increasing the injection angle by reducing the AK gap permits higher doses over smaller areas to be achieved. Such beams are of interest for the study of material property changes from ...

1994-12-31

409

Visibility of tumor-like details in inline phase contrast mammography using quasimonochromatic X-ray sources  

Energy Technology Data Exchange (ETDEWEB)

A new generation of quasimonochromatic high-flux X-ray sources, based on the X-ray radiation produced through Compton scattering between an electron beam and a laser beam, is under development. One of the possible applications of this source is inline phase contrast mammography, based on the observation of the edge-enhancement effect that can be observed at the border of structures inside the breast in images produced using a partially or totally coherent X-ray beam. In this work we present the results of a set of simulations of inline phase contrast mammography using typical inverse Compton scattering sources parameters. The simulated sample was a tumour-like mass having spherical shape, diameter between 200 {mu}m and 5 mm, placed inside a breast-like matrix, 4 cm thick, and a standard composition of 50% glandular tissue and 50% adipose tissue. We discuss the minimum requirements for mammography using inverse Compton scattering sources and we discuss how the ...

2009-09-01

410

Transient enhanced diffusion from decaborane molecular ion implantation  

Energy Technology Data Exchange (ETDEWEB)

Transient enhanced diffusion (TED) from implantation of 5thinspkeVthinspB{sub 10}H{sub 14} and 0.5 keV B ions has been quantified and compared for nominal boron doses of 10{sup 14} and 10{sup 15}thinspcm{sup {minus}2}. Boron diffusivity during annealing was extracted from secondary ion mass spectroscopy depth profiles of diffused marker layers in boron doping-superlattices and the actual implanted B dose was independently measured by nuclear reaction analysis. Comparable enhancements were observed from both ions. Transmission electron microscopy analysis revealed that both boron- and decaborane-implanted samples were amorphized at a nominal 10{sup 15}thinspcm{sup {minus}2}thinspB dose. A comparison with data from low energy Si implants revealed a similar dependence of diffusivity enhancement on implant dose. These findings are consistent with the understanding that TED is caused by the interstitial supersaturation resulting from a number of ...

1998-10-01

411

Transient enhanced diffusion from decaborane molecular ion implantation  

International Nuclear Information System (INIS)

Transient enhanced diffusion (TED) from implantation of 5keVB_1_0H_1_4 and 0.5 keV B ions has been quantified and compared for nominal boron doses of 10"1"4 and 10"1"5cm"-"2. Boron diffusivity during annealing was extracted from secondary ion mass spectroscopy depth profiles of diffused marker layers in boron doping-superlattices and the actual implanted B dose was independently measured by nuclear reaction analysis. Comparable enhancements were observed from both ions. Transmission electron microscopy analysis revealed that both boron- and decaborane-implanted samples were amorphized at a nominal 10"1"5cm"-"2B dose. A comparison with data from low energy Si implants revealed a similar dependence of diffusivity enhancement on implant dose. These findings are consistent with the understanding that TED is caused by the interstitial supersaturation resulting from a number of excess interstitials approximately equal to the number of implanted atoms ...

1998-10-01

412

Boron depth profiles and residual damage following rapid thermal annealing of low-temperature BSi molecular ion implantation in silicon  

Energy Technology Data Exchange (ETDEWEB)

The influence of substrate temperature on both the implantation and post-annealing characteristics of molecular-ion-implanted 5 x 10{sup 14} cm{sup -2} 77 keV BSi in silicon was investigated in terms of boron depth profiles and damage microstructures. The substrate temperatures under investigation consisted of room temperature (RT) and liquid nitrogen temperature (LT). Post-annealing treatments were performed using rapid thermal annealing (RTA) at 1050 deg, C for 25 s. Boron depth profiles and damage microstructures in both the as-implanted and as-annealed specimens were determined using secondary ion mass spectrometry (SIMS) and transmission electron microscopy (TEM), respectively. The as-implanted results revealed that, compared to the RT specimen, the LT specimen yields a shallower boron depth profile with a reduced tail into the bulk. An amorphous layer containing a smooth amorphous-to-crystalline (a/c) interface is evident in the LT ...

2007-08-15

413

Gamma-ray spectra from neutron capture on /sup 87/Sr  

Energy Technology Data Exchange (ETDEWEB)

The gamma-ray spectrum following neutron capture on /sup 87/Sr was measured at 3 neutron energies: E/sub n/ = thermal, 2 keV, and 24 keV. Gamma rays were detected in a three-crystal Ge(Li)-NaI-NaI pair spectrometer. Gamma-ray intensities deduced from these spectra by spectral unfolding are presented.

1981-07-01

414

Evaluation of adhesive plasters by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

A radiometric method was elaborated for surface density determinations of the adhesive layer of plasters by radionuclide X-ray fluorescence using the 17.47 keV bremsstrahlung of "1"4"7Pm/Mo. The bremsstrahlung line excites the 8.63 keV characteristic K#alpha# line of Zn contained in the adhesive layer of the plaster as a filling material in the form of ZnO. In homogeneous adhesive layers the Zn content is proportional to surface density. (author).

1976-01-01

415

High resolution alpha-particle spectroscopy using CR-39 plastic track detector  

Energy Technology Data Exchange (ETDEWEB)

A technique has been developed for high resolution alpha particle spectroscopy from track length determination in CR-39 plastic. On individual tracks an energy resolution deltaE close to the range straggling limit is obtainable. For 6 MeV alpha-particle deltaE is proportional 35 keV on individual particles and for groups of particles deltaE proportional 20 keV can be achieved using certain data selection criteria. At 100 keV on individual particles deltaE is proportional 20 keV. The analysis requires 1) a knowledge of the track-etch rate (Vsub(T))-range relationship and 2) a theoretical understanding of alpha-particle track structure in CR-39 as a function of particle energy, dip angle and degree of etching. The structure of alpha-particle etched tracks in CR-39 is described and two methods of analysis discussed. Examples are given of the resolution attainable on tracks of alpha-particles as natural ...

1984-06-15

416

Study of silicon damage caused by ultra-low energy boron implantation  

International Nuclear Information System (INIS)

Ultra-shallow junction formation in deep submicron Si devices is limited by anomalous diffusion of the dopant, which is related to the release of interstitials from defect clusters formed during the implantation of energetic ions or the subsequent annealing. The work described in this dissertation is concerned with the effects of low energy B ion implantation, especially damage formation, clustering and its annealing. After a review of the stopping and ranges of energetic ions in Si, the formation of implant damage, in particular of point defects, their migration, agglomeration and annihilation, including the involvement of dopant ions, is considered. A description of the Salford ultra low energy implanter is given and the main analysis technique, medium ion energy scattering (MEIS) reviewed. Additional analytical techniques used, such as secondary ion mass spectrometry (SIMS), 4-point probe and cross section transmission microscopy (XTEM) as well as TRIM simulation are briefly ...

417

Pre-Flight Development of the PoGOLite Pathfinder  

International Nuclear Information System (INIS)

The Polarized Gamma-ray Observer (PoGOLite) is a balloon-borne instrument that will measure gamma-ray polarization in the energy range 25-80 keV from astronomical sources such as pulsars, accretion discs and jets from active galactic nuclei. The two additional parameters provided by such observations, polarization angle and degree, will allow these objects to be studied in a new way, providing information about their emission mechanisms and geometries. The instrument measures azimuthal scattering angles of photons within a close packed array of phoswich detector cells (PDCs) based on coincident detection of Compton scattering and photoelectric absorption. Each PDC comprises three different scintillating components and combines photon detection, active collimation and bottom anticoincidence into one single unit. The three parts are viewed by a photomultiplier tube (PMT) and pulse shape discrimination is used to identify signals from dierent parts. Surrounding the ...

418

X-ray dosimetry of TlGaSe_2 single crystals  

International Nuclear Information System (INIS)

TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. X-ray conductivity coefficients K_#sigma# characterising X-ray sensitivity of investigated crystals are determined as the relative ...

419

XAFS studies of nanocomposite systems  

Science.gov (United States)

Nanosized particles are important because of their unique properties, different from the bulk, which leads to their enhanced catalytic, photocatalytic and electronic properties. This work has dealt with three different nanoparticle systems in the context of three different aspects of nanoparticle properties: (a) photocatalytis (TiO2/metal) system, (b) luminescence (CdSe) (c) alloying (Pt-Ag and Pd-Ag). The initial photocatalytic enhancement obtained by adding noble metal on semiconductor nanoparticles, degrades as fast as in 15 minutes and questions their long-term performance. XANES measurements on such irradiated systems like TiO2/Au, TiO2/Pt, TiO2/Ir indicates a positive oxidation state of these noble metals which renders them as recombination centers for photo-excited electrons and explains the decreased photocurrent. The oxidation is caused by holes. The EXAFS results also indicate a change of the interfacial structure ...

420

Luminescence of Strontianite (SrCO{sub 3}) from Strontian (Scotland, UK)  

Energy Technology Data Exchange (ETDEWEB)

An historic Strontianite-type specimen from Strontian, Scotland, UK, was characterized to broaden our knowledge on luminescence properties of common carbonates. These fibrous aggregates are Strontianite (Sr{sub x}Ca{sub 1-x}CO{sub 3}) with circa 6% of CaO, interfacial water, hydrosilicate anions and substitutional divalent cations, e.g., Ca{sup 2+}, Mn{sup 2+}, Fe{sup 2+} in structural Sr{sup 2+} positions. The specimen was analyzed by X-ray Fluorescence Spectrometry (XRF), Environmental Scanning Electron Microscopy coupled with an Energy Dispersive X-ray Spectroscopy (ESEM-EDS) probe, Spatially-resolved Cathodoluminescence under the Scanning Electron Microscope (SEM-CL), Differential-Thermal Analyses (DTA), Thermogravimetry (TG), Thermoluminescence (TL), Radioluminescence (RL) and High Resolution Spectra Thermoluminescence (3DTL), to gain an overview of the spectral emissions, the defect linkages were modified by heating from room temperature ...

2009-04-15

421

Concrete peeling off device  

Energy Technology Data Exchange (ETDEWEB)

The present invention concerns a device for peeling off activated concretes in processing for discarding a reactor of a nuclear reactor facility. The device comprises a gyrotron for generation microwaves, an irradiator for irradiating output microwaves, a reflection mirror for reflecting and converging the microwaves and irradiating them to a material to be irradiated and a first rotating means for rotating the irradiator and the reflection mirror in parallel with the axis of the gyrotron while maintaining the positional relation between the irradiator and the reflection mirror. When the position of the microwaves irradiated on concrete walls are moved in a circumferential direction and the central axes of the rotational axis and the material to be irradiated are aligned, then the intensity of the ...

1997-11-28

422

Neutron irradiation effects on plasma facing materials  

Energy Technology Data Exchange (ETDEWEB)

This paper reviews the effects of neutron irradiation on thermal and mechanical properties and bulk tritium retention of armour materials (beryllium, tungsten and carbon). For each material, the main properties affected by neutron irradiation are described and the specific tests of neutron irradiated armour materials under thermal shock and disruption conditions are summarized. Based on current knowledge, the expected thermal and structural performance of neutron irradiated armour materials in the ITER plasma facing components are analysed.

2000-12-01

423

Production of high-q ions by laser bombardment method  

International Nuclear Information System (INIS)

The expanding plasma produced when an intense pulse of laser radiation is focused in vacuum onto a solid target has been used as a source of highly stripped ions for collision cross-section measurements. Usable fluxes of carbon nuclei at energies of a few hundred eV/charge have been obtained by irradiation of graphite with pulses of CO"2 laser radiation at a focused power density of 3 x 10_1_0 W/cm_2. Bombardment of aluminum and iron targets at comparable power levels have yielded ions of maximum charges of 9 and 16 respectively. A time-of-flight apparatus has been constructed to utilize the laser source for measurement of electron capture cross sections for highly stripped ions in gases at energies in the few hundred eV/charge range. Apertures collimate an ion beam from the plasma blowoff, and an electrostatic analyzer selects ions from the expanding plasma which have the same energy per charge. The beam is directed through a gas target cell, ...

1981-01-01

424

In situ corrosion studies on selected high level waste packaging materials under simulated disposal conditions in rock salt formations  

International Nuclear Information System (INIS)

This paper reports about in-situ corrosion studies on selected materials for long-term resistant high-level waste (HLW) packagings acting as a barrier in a rock salt repository. The materials (Ti 99.8-Pd, Hastelloy C4 and five iron-base materials) were investigated in heated boreholes in the Asse salt mine under simulated HLW disposal conditions prevailing in normal operation of repository and in certain accident scenarios. The experiments under normal operating conditions were performed at temperatures of 120 deg. C to 210 deg. C (vertical temperature profile in the boreholes) without and with gamma irradiation (3#centre dot#10"2 Gy/h, Co-60 source) within the framework of the German/US Brine Migration Test. In these experiments only small amounts of migrated brine inclusions (NaCl-rich) from the rock salt were present as corrosion medium. In the experiments carried out under simulated accident conditions with intrusion of larger amounts of NaCl brine into the HLW ...

1993-02-01

425

Measurement and analysis of neutron production cross sections and determination of some reaction rates for nuclear astrophysical calculations  

International Nuclear Information System (INIS)

The absolute cross sections of "2"3Na(p,n)"2"3Mg, "2"7Al(p,n)"2"7Si and "3"0Si(#alpha#,n)"3"3S reactions were measured in the incident energy range of 5.05 to 5.80, 5.80 to 6.25 and 3.975 to 6.235 MeV respectively using a spherically shaped 4#pi# neutron detector. In the energy range 5.80 to 7.80 and 6.235 to 11.30 MeV the absolute cross sections of "2"3Na(p,n)"2"3Mg and "3"0Si-(#alpha#,n)"3"3S reactions were determined by optical model calculations. The cross sections of the inverse reactions "2"3Mg(n,p)"2"3Na and "3"3S(n,#alpha#)"3"0Si were also calculated by the same method for the neutron energy range of 10 keV to 7.50 MeV for each reaction. The cross section of the latter reaction in the neutron energy range of 10 keV to 840 keV was also determined from its inverse reaction "3"0Si(#alpha#,n)"3"3S by the application of the detailed balance theorem. The reactions for which the cross sections were determined are of ...

426

Progress of negative-ion based NBI system for JT-60U  

Energy Technology Data Exchange (ETDEWEB)

The operation of the negative ion based NBI system for JT-60U has been progressed since 1996. Most of the efforts in the operation for increasing beam power and energy have been concentrated to get over the troubles, caused by surge energy at the moment of the accelerator break-down, in the ion sources and high voltage power supplies. The ion source for the N-NBI, so far, has accelerated negative ion beams of 14.3 A at 380 keV with deuterium and 18.5 A at 360 keV with hydrogen against the target of 22 A. The neutral beam power injected into JT-60U has already reached 5.2 MW at 350 keV for 0.7 sec with deuterium. (author)

1998-07-01

427

Negative-ion based NBI system for JT-60U  

Energy Technology Data Exchange (ETDEWEB)

A 500 keV negative-ion based NBI system is under construction for NB current drive and plasma core heating in high density plasma in JT-60U. Part of the beamline and the high voltage power supply required for a verification test of an ion source was completed in March 1995. After having done a high potential test of the power supply, the negative-ion generation and acceleration tests started in June 1995 aiming at deuterium beams of 500 keV, 22A. In initial experiment, deuterium negative-ion beams of 410 keV, 6.1A (2.5 MW) for 0.2 sec, so far, have been achieved. This is the world highest D{sup {minus}} current and negative ion beam power. The construction of the total system will be completed by the beginning of 1996, and the beam injection will start in March 1996.

1995-12-31

428

Measurement of attenuation coefficients for bone, muscle, fat and water at 140, 364 and 662keV ?-ray energies  

International Nuclear Information System (INIS)

The half-value thicknesses, linear and mass attenuation coefficients of biological samples such as bone, muscle, fat and water have been measured at 140, 364 and 662keV ?-ray energies by using the ATOMLABTM-930 medical spectrometer. The ?-rays were obtained from 99mTc, 131I and 137Cs ?-ray point sources. Also theoretical calculations have been performed in order to obtain the half-value thicknesses and, mass and linear attenuation coefficients at photon energies 0.001keV-20MeV for bone, muscle and water samples. The calculated value and the experimental results of this work and the other results in literature are found to be in good agreement.

2006-11-01

429

Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr  

Energy Technology Data Exchange (ETDEWEB)

Neutron capture ..gamma..-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.

1985-01-15

430

Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr  

International Nuclear Information System (INIS)

Neutron capture #gamma#-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.

1984-09-10

431

Irradiation damage in superconductors  

International Nuclear Information System (INIS)

Most superconductors are quite sensitive to irradiation defects. Critical temperatures may be depressed, critical currents may be increased, by irradiation, but other behaviours may be encountered. In compounds, the sublattice in which defects are created is of significant importance. 24 refs.

1989-05-08

432

Differential Effect of Irradiance and Nutrient Nitrate on the Relationship of in Vivo and in Vitro Nitrate Reductase Assay in Chlorophyllous Tissues 1  

UK PubMed Central (United Kingdom)

Growth at increasing continuous irradiance (at high nutrient nitrate) and nutrient nitrate concentrations (at high continuous irradiance) furnished increases in the in vivo and in...Full Text Available

1977-04-01

433

Consideration of radiation effects in the choice of packaging materials  

International Nuclear Information System (INIS)

Requirements for food packaging materials include whether there is any interaction between the food and the package during or after the irradiation, and whether as a result of the irradiation, volatile or leachable substances are released from the pack into the food. The performance of cellulose-based materials and plastic films under irradiation are discussed.

434

Study of the effects of a prenatal or postnatal irradiation of 150 rads in adult rats  

International Nuclear Information System (INIS)

Pregnant females and newborn rats were exposed to a gamma irradiation of 150 rads. The stage of gestation at the time of irradiation varied from 14 to 21 days. The newborn rats were irradiated at 0, 1 and 2 days of age. The effect of irradiation of foetus and newborn rats depends on the age of the animal at the time of irradiation. This effect was specially important at the beginning of the foetal life. Neonatal mortality, growth of body weight and adult brain development were investigated. A modification of germ cell radiosensitivity during the period studied, was emphasized.

435

Yields of Residual Nuclei from Proton-Irradiated Materials  

International Science & Technology Center (ISTC)

Experimental and Theoretical Study of the Residual Nuclide Production in 40-2600 MeV Proton-Irradiated Thin Targets of ADS Basic Materials

436

The sensory quality of irradiated breaded poultry products  

International Nuclear Information System (INIS)

The colour, odour, flavour and texture of a breaded turkey escalope irradiated at doses of 2 and 4 kGy was assessed using a trained sensory panel. Irradiation did not affect raw appearance but during storage the irradiated breaded products became paler than the control samples. The off odour of the raw irradiated products was stronger than that of the unirradiated samples. Irradiation also affected the odour, flavour and texture of the cooked products. Although the trained panelists were able to detect significant differences between irradiated and unirradiated breaded turkey escalopes, the numerical differences between treatments were often quite small. It is possible that an untrained consumer group would be unable to detect these differences. Further research is needed with consumer groups to establish if irradiated breaded products are ...

1994-07-01

437

Radiation Damage Calculations for the FUBR and BEATRIX Irradiations of Lithium Compounds in EBR-II and FFTF  

Energy Technology Data Exchange (ETDEWEB)

Radiation Damage Calculations for the FUBR and BEATRIX Irradiations of Lithium Compunds in EBR-II and FFTF

1999-05-01

438

Endurance of cultured pearls irradiated with gamma-rays  

International Nuclear Information System (INIS)

Pearls change their color to grey by #gamma#-ray irradiation. Grey densities were determined from darkness of pearl nuclei and thickness of the pearl layers. The densities are independent of both diameters of nuclei and pearls. The fading rate increases with increasing storage temperature. The rate of fading for irradiated pearls is lower than that for natural blue pearls. Comparison of photomicrographs (x 12) for pearls irradiated and then stored at room temperature for about 6 years revealed that their surfaces are not substantially different from the surfaces of unirradiated cultured pearls, indicating that #gamma# irradiation hardly gives rise to deterioration. #gamma#-Ray irradiation is a technique for coloration of pearls. Irradiated blue pearls seem to have resistivity to fading and to deterioration of the surface, if pearls have been ...

439

Determination of alcohols, esters and organic acids in irradiated sweet potato wine by capillary gas chromatography  

International Nuclear Information System (INIS)

This paper presents the analytical results of alcohols, esters and organic acids in sweet potato wine irradiated by #gamma#-rays. (author).

440

Determination of absorbed dose in a patient irradiated by beams of x or gamma rays in radiotherapy procedures  

CERN Document Server

Determination of absorbed dose in a patient irradiated by beams of x or gamma rays in radiotherapy procedures

1976-01-01

441

Coloring of cultured pearls by gamma-rays irradiation  

International Nuclear Information System (INIS)

Changing cream pearls into bluish-grey by #gamma# ray irradiation is a technique in coloring of pearls. Irradiated pearls are similar in color to cultured blue pearls. The pearl layers hardly change their color but the nuclei change into dark brown by irradiation. Visible light (500 - 700 nm) penetrating the pearl layer is absorbed by dark brown nucleus. The intensity of reflecting light between 400 and 500 nm at pearl surface, therefore, becomes stronger than that between 500 and 700 nm; therefore color of irradiated pearls look bluish-grey. The density of bluish-grey color increases with increasing absorbed doses, but their luster at surface diminishes owing to the deterioration of the pearl layer by prolonged irradiation; high doses irradiation should be avoided. Irradiated pearls show no substantial fading of their color in a year and ...

442

The result of Alanine/ESR dosimetry at Wolsung unit 1  

International Nuclear Information System (INIS)

It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate dose, two environmental correction factors, irradiation temperature and ...

2008-10-01

443

Structural transformations in Sc/Si multilayers irradiated by EUVlasers  

Energy Technology Data Exchange (ETDEWEB)

Multilayer mirrors for the extreme ultraviolet (EUV) are keyelements for numerous applications of coherent EUV sources such as newtabletop lasers and free-electron lasers. However the field ofapplications is limited by the radiation and thermal stability of themultilayers. Taking into account the growing power of EUV sources thestability of the optics becomes crucial. To overcome this problem it isnecessary to study the degradation of multilayers and try to increasetheir temporal and thermal stability. In this paper we report the resultsof detailed study of structural changes in Sc/Simultilayers when exposedto intense EUV laser pulses. Various types of surface damage such asmelting, boiling, shockwave creation and ablation were observed asirradiation fluencies increase. Cross-sectional TEM study revealed thatthe layer structure was completely destroyed in the upper part ofmultilayer, but still survived below. The layers adjacent tothe substrateremained intact even ...

2007-08-21

444

Simulating quantum search algorithm using vibronic states of I_2 manipulated by optimally designed gate pulses  

International Nuclear Information System (INIS)

In this paper, molecular quantum computation is numerically studied with the quantum search algorithm (Grover's algorithm) by means of optimal control simulation. Qubits are implemented in the vibronic states of I_2, while gate operations are realized by optimally designed laser pulses. The methodological aspects of the simulation are discussed in detail. We show that the algorithm for solving a gate pulse-design problem has the same mathematical form as a state-to-state control problem in the density matrix formalism, which provides monotonically convergent algorithms as an alternative to the Krotov method. The sequential irradiation of separately designed gate pulses leads to the population distribution predicted by Grover's algorithm. The computational accuracy is reduced by the imperfect quality of the pulse design and by the electronic decoherence processes that are modeled by the non-Markovian master equation. However, as long as we focus ...

2010-04-01

445

Radiation grafting processes and properties of leathers modified with butyl acrylate  

International Nuclear Information System (INIS)

Conditions for radiation induced grafting with butyl acrylate dispersed in water emulsion onto chrome-tanned pig skins have been worked out for #gamma#-rays and electron beam irradiations. The highest yield of grafting was observed at monomer concentration approximately 25% (w/w), dose equal to 25 kGy and dose rate not exceeding 10 MGy/h. At these conditions the yield of grafting attained a value approximately 25% and content of homopolymer in the leather amounted to 6%. The efficiency of monomer to polymer conversion decreases when the concentration of monomer in emulsion and dose rate increases. Yield of homopolymer is independent of the dose rate. An explanation of the observed relations has been proposed. The physical and used properties of grafted leathers were tested. Radiation processed leathers were found superior to samples finished by traditional methods. One has to point to better tolerance against chemical cleaning and reduced water ...

1982-01-01

446

Preservation of beech and spruce wood by allyl alcohol-based copolymers  

International Nuclear Information System (INIS)

Allyl alcohol (AA), acrylonitrile (AN), methyl methacrylate (MMA), monomers and monomer mixtures AA+AN, AA+MMA were used to conserve and consolidate Beech and Spruce. After impregnation, copolymerisation and polymerisation were accomplished by gamma irradiation. The fine structure of wood+polymer(copolymer) composites was investigated by Scanning Electron Microscopy (SEM). It was observed that copolymer obtained from AA+MMA monomer mixture showed the optimum compatibility. The compressional strength and Brinell Hardness Numbers determined for untreated and treated wood samples indicated that the mechanical strength of wood+copolymer composites was increased. It was found that the mechanical strength of the wood samples containing the AA+MMA copolymer was higher than the others. In the presence of P(AA/MMA), at highest conversion, the compressive strength perpendicular to the fibres in Beech and Spruce increased approximately 100 times. The ...

1999-06-01

447

Mechanical property of superplastic-deformed ceramics by micro-indentation method  

Energy Technology Data Exchange (ETDEWEB)

A neutron irradiation test on superplastic ceramic materials at high temperature has been proposed as an innovative basic research on high-temperature engineering using the High Temperature Engineering Test Reactor (HTTR). We investigated mechanical properties, such as the hardness and Young's modulus, of ceramic specimens after superplastic deformation. The tested material was 3Y-TZP (3mol% Yttria stabilized Tetragonal Zirconia Polycrystal) which is one of the representative superplastic ceramics. The properties were measured by a microindentation method. We also studied the relationship between crystal microstructures and the mechanical properties of deformed 3Y-TZP by scanning electron microscope (SEM). The indentation test showed that the mechanical properties of the specimens were reduced to about 1/2 by 30% deformation and to about 1/4 by 150% deformation. The SEM images showed that average grain size and deviation of grain size ...

2001-03-01

448

Lysozyme dimer formation on lysozyme oxidation with B./2 as studied by fluorescence evolution  

International Nuclear Information System (INIS)

Lysozyme dimers produced on oxidation of lysozyme with Br_2anion radicals in aqueous solutions exhibit a fluorescence spectrum (lambdasub(max) = 400 nm) closely similar to that of bi-tyrosine. This suggests that the dimer is likely to have a tyrosine-tyrosine bond resulting from the combination of tyrosine phenoxy radicals of two lysozyme molecules. Kinetic studies on dimer formation were made by measuring time-dependent fluorescence after pulsed-electron irradiation over wide pH range. The results lead to the following conclusions. The second-order growth of the dimer fluorescence observed at pH 10.7-12.5 reflects the combination process of the lysozyme radicals, which is rate-determining in the pH range. On the other hand, the first-order growth observed at pH 6.8-10.2 is attributable to the enolization of the keto-form of the dimer. A tentative reaction scheme is proposed for the dimer formation. (author).

449

Laser induced local and periodic phase transformations in iron oxide thin films obtained by chemical vapour deposition  

International Nuclear Information System (INIS)

Iron oxide films have been deposited on Si(100) substrates by chemical vapour deposition (CVD) of iron(III) tert-butoxide ([Fe(O "tBu)_3]_2) in the temperature range 350-450 deg. C. The precursor flux and substrate temperature were varied to control the phase composition, average grain size and film thickness. The nature of substrate and deposition temperature markedly influence the morphology and iron-oxygen stoichiometry in the CVD deposits. Phase transformations in iron oxide films were achieved through precise local and periodic heating of the films by interfering laser beams. The interaction of iron oxide films with short laser pulses (Nd:YAG, 355 nm) induced partial transformation of hematite (#alpha#-Fe_2O_3) to magnetite (Fe_3O_4) or magnetite to wuestite (Fe_1_-_xO), respectively. The phase characterization and morphology of the hematite and magnetite films were investigated before and after laser irradiation by X-ray diffractometry, high resolution ...

2005-07-15

450

Grating-based X-ray phase imaging using multiline X-ray source  

International Nuclear Information System (INIS)

Differential phase-contrast X-ray imaging has been performed in a Talbot-Lau configuration, where a multiline X-ray source was used instead of a combination of a hard-X-ray multiple slit and a normal focus X-ray generator. When the multiple slit is used, a high aspect ratio structure is needed and slit width should be below 10 ?m for its function. The fabrication and use of such a multislit can be omitted using the presented configuration. The multiline X-ray source was developed by making grooves on a tungsten rotating anode, which was irradiated by an electron beam to generate X-rays. An array of 10?m line sources with a pitch of 30?m was formed and combined with a 4.5 ?m pitch phase grating and a 5.3 ?m pitch amplitude grating to generate differential phase contrast. With a total exposure time of 40 s, a differential phase image depicting cartilages was obtained. (author)

2009-07-01

451

Full autonomous monitoring tools inside nuclear reactor building  

Energy Technology Data Exchange (ETDEWEB)

In this paper, we define, design and test a radiation tolerant autonomous monitoring tool for nuclear embedded applications. The goal of the instrumentation system was to record the values of some parameters such as dose, temperature or vibrations appearing inside the containment building of nuclear power plants. The knowledge of these parameters will be a good help for predictive maintenance of the power plant components. For the design of the monitoring tool, we rely on commercial-off-the-shelf (COTS) low power electronic components to use battery-supplied power. A large amount of components starting from discrete transistors or logic units to memories and micro-controllers was associated to define and design a prototype. We then confirm the environment conditions tolerance estimated to up to 2 kGy of total dose and 80 C for temperature by on-line irradiation experiments for individual components and functions and prototypes. Two different ...

2009-07-01

452

DNA alterations photosensitized by tetracycline and some of its derivatives  

Energy Technology Data Exchange (ETDEWEB)

Bacteriophage M13 mp10 DNA were irradiated with near-UV light in the presence of tetracycline derivatives and primed with synthetic oligonucleotide to be used for DNA synthesis using Escherichia coli DNA polymerase. Chain terminations were observed by denaturing polyacrylamide gel electrophoresis and mapped precisely. All the synthesis stops occurred before or at the level of guanine residues, showing that the photoreaction mediated by tetracycline derivatives led to a preferential alteration of guanine residues. These lesions were demonstrated to be induced in DNA through a pathway involving singlet oxygen. Tetracycline derivatives also photoinduced the breakage of the DNA sugar-phosphate backbone monitored by the conversion of supercoiled phi X174 DNA to a relaxed form. This lesion was shown to be initiated by hydroxyl radicals. The production of this free radical has been confirmed by electron paramagnetic resonance (EPR) spin trapping ...

1986-06-01

453

Composition Dependence of the Photocatalytic Activities of BiOCl1-xBrx Solid Solutions under Visible Light  

British Library Electronic Table of Contents (United Kingdom)

Abstract We prepared BiOCl1-xBrx (x=0-1) solid solutions and characterized their structures, morphologies, and photocatalytic properties by X-ray diffraction, diffuse reflectance spectroscopy, scanning electron microscopy, Raman spectroscopy, photocurrent and photocatalytic activity measurements and also by density functional theory calculations for BiOCl, BiOBr, BiOCl0.5Br0.5. Under visible-light irradiation BiOCl1-xBrx exhibits a stronger photocatalytic activity than do BiOCl and BiOBr, with the activity reaching the maximum at x=0.5 and decreasing gradually as x is increased toward 1 or decreased toward 0. This trend is closely mimicked by the photogenerated current of BiOCl1-xBrx, indicating that the enhanced photocatalytic activity of BiOCl1-xBrx with respect to those of BiOCl and BiO...

2011-01-01

454

Cluster-assisted multiple ionization of methyl iodide by a nanosecond laser: Influence of laser intensity on the kinetic energy and peak profile of multicharged ions  

International Nuclear Information System (INIS)

The dependences of kinetic energies and peak profiles of multicharged ions of I "q"+ (q = 2-3) and C"2"+ on the laser intensity have been studied in detail by time-of-flight mass spectrometry, those multicharged ions are produced by irradiation of methyl iodide cluster beam with a nanosecond 532 nm Nd-YAG laser. Our experiments show that the kinetic energies released of multicharged ions increase linearly with the laser intensity in the range of 3 x 10"9-2 x 10"1"1 W/cm"2. The peaks of multicharged ions are split to forward ions and backward ions, and the ratio of the backward ions to forward ions decreases exponentially with laser intensity. The decreasing of backward ions is probably due to Coulomb scattering by the heavier I"+ ions when they turn around through the laser focus point. The linear dependence of kinetic energy of multicharged ions on laser intensity is interpreted by the ionization mechanism, in which the laser induced inverse bremsstrahlung heating ...

2006-03-20

455

Air breakdown induced by a high-power short-pulse microwave  

Energy Technology Data Exchange (ETDEWEB)

At Himeji Institute of Technology, the high power microwaves with the peak power of 20 MW, frequency of 12 GHz and pulse duration of 14 ns have been produced with a virtual cathode oscillator (vircator). These high power microwaves offer new applications in various fields. One problem in laser-triggered lightning experiment is the strong attenuation of laser energy by rain, cloud and laser-produced plasma. Microwaves propagate in thundercloud with small loss, and also are able to irradiate much extensive region of targets. In this paper, the fundamental experiment on the air breakdown induced by high power, short pulse microwaves is reported. The experimental setup of the vircator diode for microwave generation is shown. The typical evolution of diode voltage, electron beam current and microwave emission from the top in the course of time is shown. The experimental setup for microwave-induced air breakdown and the experimental procedure are ...

1996-05-01

456

Scanning Electron Microscope Examination of Cotton Linters ...  

Science.gov (United States)

... TECHNICAL REPORT ARBRL-TR-02476 SCANNING ELECTRON MICROSCOPE ... SCANNING ELECTRON MICROSCOPE EXAMINATION OF ...

1983-03-01

458

Transmutation of technetium in the Petten HFR. A comparison of measurements and calculations  

Energy Technology Data Exchange (ETDEWEB)

Within the framework of the EFTTRA cooperation between CEA, ECN, EDF, FZK, IAM and ITU, six metallic {sup 99}Tc rods have been irradiated in the Petten HFR for 193 effective full power days. During this irradiation, more than 6% of the {sup 99}Tc has been transmuted to the stable {sup 100}Ru. At ECN, one of the six rods has been examined in the hot cell laboratory. The ruthenium concentration in the rod measured by Isotope Dilution Mass Spectrometry reaches 6.4% at 5 mm from the bottom of the rod and 6.0% at 5 mm from the top. Also the axial and radial distributions of the ruthenium have been measured by Electron Probe Micro Analysis. The ruthenium concentrations calculated by the three-dimensional Monte Carlo code KENO reach 6.1% at 5 mm from the bottom of the rod and 5.7% at 5 mm from the top. These values are in reasonable agreement with the measured ones. However, the calculated radial distribution of the ruthenium ...

1996-10-01

459

Results of electron beam therapy using intra-oral cone for carcinoma of the oral tongue  

Energy Technology Data Exchange (ETDEWEB)

Retrospective analyses were performed to evaluate the therapeutic efficacy of intra-oral cone (IOC) radiation therapy for carcinoma of the oral tongue, especially about its faculty of local control and complications. Thirty-nine patients with squamous cell carcinoma of the oral tongue were treated with IOC radiation therapy alone or in combination with external irradiation. IOC radiation therapy was given not only for T1 and T2, but also for T3 tumors. Hypofractionation was used for IOC radiation therapy. The 2 year local control rates, including surgical salvage, for T1, T2, T3 and T4 were 100%, 73.3%, 40% and 0%, respectively. The 5 year actuarial survival rates for Stage I, II, III and IV were 100%, 65.3%, 35.4% and 0%, respectively. The incidences of radiation complications, i.e. soft tissue ulceration and osteoradionecrosis, were 42.9% and 2.9%, respectively. It is suggested that relatively high rate of soft tissue ulceration was due to hypofractionation. We ...

1992-07-01

460

Organ culture of mammalian skin and the effects of ultraviolet light and testosterone on melanocyte morphology and function  

Science.gov (United States)

Scrotal skin of black Long-Evans rats and human thigh skin were maintained in vitro as organ cultures for as long as 14 days, and examined histologically using the combined skin splitting and Dopa techniques. Selected rat skin cultures received testosterone in the culture medium and/or were irradiated with ultraviolet light (290 to 320 nm uvl). With increased time in culture, scrotal melanocytes round up and there is an increase in epidermal pigmentation. Human skin behaves similarly; after eight days in vitro human melanocytes also become rounded, but remain strongly Dopa-positive. Addition of exogenous testosterone to cultured rat skin maintains dendritic morphology of melanocytes, but cell body size is still reduced. uvl irradiation stimulates melanocytes in rat skin cultures, maintaining their dendritic morphology and increasing epidermal and dermal pigmentation. Cultured skin receiving both uvl and testosterone illustrates a synergistic ...

1978-05-01

461

Molybdenum. Suppl. Vol. A 2a. Element. Physical properties. Pt. 1. 8. Rev. Ed  

Energy Technology Data Exchange (ETDEWEB)

The major part of the chapter 'Physical Properties' in concerned with, in addition to nuclear and atomic properties, the properties of the metal molybdenum. Due to the huge number of relevant papers, the present volume comprises only the first part of the metal properties, i.e. the crystallographic properties, the electronic structure, the lattice dynamics, and subsequently the mechanical and thermal properties. There are two small sections where the properties of the molecules, primarily Mo/sub 2/ and Mo/sub 6/, and of the vapor are described. The strength and some other mechanical properties have been frequently investigated to establish the change due to neutron irradiation, because this affects the durability of the fuel containers in nuclear reactors. For that purpose, changes in structure, texture, etc., due to irradiation had to be determined; the structural properties of nonirradiated samples also ...

1985-01-01

462

Luminescence Properties of ScPO{sub 4} Single Crystals  

Energy Technology Data Exchange (ETDEWEB)

Flux-grown ScPO{sub 4} single crystals exhibit a number of luminescence bands in their x-ray-excited luminescence spectra - including sharp lines arising from rare-earth elements plus a number of broad bands at 5.6 cV, 4.4 eV, and 3 eV. The band at 5.6 eV was attributed to a self-trapped exciton (STE) [l], and it could be excited at 7 eV and higher energies. This luminescence is strongly polarized (P = 70 %) along the optical axes of the crystal and exhibits a kinetic decay time constant that varies from several ns at room temperature to {approximately}10 {micro}s at 60 K and up to {approximately}1 ms at 10 K. It is assumed that the STE is localized on the SC ions. The band at 3 eV can be excited in the range of the ScPO{sub 4} crystal transparency (decay time = 3 to 4 {micro}s.) This band is attributed to a lead impurity that creates different luminescence centers. At high temperatures, the band at 4.4 eV is dominant in the x-ray-excited TSL and afterglow spectra. Its intensity ...

1999-08-16

463

Functional and physical molecular size of the chicken hepatic lectin determined by radiation inactivation and sedimentation equilibrium analysis  

Energy Technology Data Exchange (ETDEWEB)

Radiation inactivation and sedimentation equilibrium analysis were used to determine the functional and physical size of the chicken hepatic membrane receptor that binds N-acetylglucosamine-terminated glycoproteins. Purified plasma membranes from chicken liver were irradiated with high energy electrons and assayed for 125I-agalactoorosomucoid binding. Increasing the dose of ionizing radiation resulted in a monoexponential decay in binding activity due to a progressive loss of binding sites. The molecular mass of the chicken lectin, determined in situ by target analysis, was 69,000 +/- 9,000 Da. When the same irradiated membranes were solubilized in Brij 58 and assayed, the binding protein exhibited a target size of 62,000 +/- 4,000 Da; in Triton X-100, the functional size of the receptor was 85,000 +/- 10,000 Da. Sedimentation equilibrium measurements of the purified binding protein yielded a lower limit molecular weight of ...

1990-03-05

464

Beta-delayed proton emission: a new series of precursors, and the measurement of 10"-"1"6 s nuclear lifetimes  

International Nuclear Information System (INIS)

The results of investigation into a new series of Z-even nuclei - precursors of delayed protons (PDP) -"6"5Ge, "8"9Se, "9"3Kr, "8"1Zr, and "8"5Mo are presented. PDP were obtained by irradiation of targets in the following reactions: Zn(He, 2n) "6"5Ge, 22 MeV; "4"0Ca("3"2S, 2 pn) "1"9Se, 100 MeV; "6"0Ni ("1"60, 3 n), "7"3Kr, 75 MeV; "5"2Cr ("3"2S, 3n)"8"1Zr, 110 MeV; "5"6Fe("3"2S, 3n)"8"5Mo, 120 MeV. The targets (self-sustaining foils of thickness approximately 1.2 mg/cm"2) were placed at an angle of 15 deg to the direction of the ion beam. Upon irradiation targets were moved downwards into a measuring position. The spectra of protons, X and gamma-rays, and also the spectra of p - x, p-#gamma#, x - #gamma# coincidences accompanying the decay of "6"5Ge, "6"9Se,"7"3Kr and "8"1Zr, and "8"5Mo were measured. The measured half-lives are equal, to 31.5+-1.9, 27.3+-0.5, 28.5+-1.1, 6.3+-0.5, and 5.6 +-0.9 s respectively. The experimental spectra are ...

465

Traditional Fusion reaction: D + T n (14.07 MeV) + 4He (3.52 MeV ...  

Science.gov (United States)

as for direct energy conversion in specialized direct electrical energy conversion plants. Figure 1. An energetic (~163KeV) proton and a 11boron nucleus fuse ...

466

The study of "1"0"1Mo decay  

International Nuclear Information System (INIS)

The decay of "1"0"1Mo to levels in "1"0"1Tc has been studied using the three-parameter (#gamma#-#gamma#-t) coincidence system of HpGe-HpGe detectors. According to the coincidence data, the decay scheme was modified. The positions of 221.80, 318.00, 377.90, 452.50, 515.42, 1011.05 and 1759.72 keV transitions have been arranged again, the transition positions of 104.70, 105.95 and 774.15 keV gamma-rays have been assigned for the first time, the positions of 169.00, 590.91, 980.52 and 1431.68 keV transitions have been reconfirmed, the 1508.01 keV gamma-ray was observed simultaneously for the first time and its transition position has been assigned. The #beta#-intensities and the values of log ft of most levels were calculated. (author)

2000-09-01

467

Studies on energy level schemes of some nuclei by Gamma-ray spectroscopy  

International Nuclear Information System (INIS)

several authors tried to drive codes to construct nuclear level scheme of nuclei using a set of measured gamma -ray transitions and known energy levels, Ritz combination principle proved to be useful in constructing a more complete decay scheme. In this thesis the energy level schemes of some nuclei have been investigated by the measurements of the gamma - ray energies and use of Ritz combination code. The nuclei under investigation are "110m Ag (253 d)"110 Cd and "166m Ho (1200 yr) "166 E r. On the basis of the suggested level at 2249.02 keV by the Ritz code new positions of the two gamma-ray transitions at 677.5 and 706.6 KeV are found in decay scheme of "110m Ag. Also by this code, new position for the 994.84 KeV gamma-ray transition were established to depopulate the level at 1075.2 KeV.

1984-01-01

468

Mechanism for the reduction of interstitial supersaturations in MeV-implanted silicon  

Energy Technology Data Exchange (ETDEWEB)

We demonstrate that the excess vacancies induced by a 1 MeV Si implant reduce the excess interstitials generated by a 40 keV Si implant during thermal annealing when these two implants are superimposed in silicon. It is shown that this previously observed reduction is dominated by vacancy annihilation and not by gettering to deeper interstitial-type extended defects. Interstitial supersaturations were measured using B doping superlattices (DSL) grown on a silicon-on-insulator (SOI) substrate. Implanting MeV and keV Si ions into the B DSL/SOI structure eliminated the B transient enhanced diffusion normally associated with the keV implant. The buried SiO{sub 2} layer in the SOI substrate isolates the deep interstitials-type extended defects of the MeV implant, thereby eliminating the possibility that these defects getter the interstitial excess induced by the keV Si implant. {copyright} {ital 1999 ...

1999-03-01

469

Mechanism for the reduction of interstitial supersaturations in MeV-implanted silicon  

International Nuclear Information System (INIS)

We demonstrate that the excess vacancies induced by a 1 MeV Si implant reduce the excess interstitials generated by a 40 keV Si implant during thermal annealing when these two implants are superimposed in silicon. It is shown that this previously observed reduction is dominated by vacancy annihilation and not by gettering to deeper interstitial-type extended defects. Interstitial supersaturations were measured using B doping superlattices (DSL) grown on a silicon-on-insulator (SOI) substrate. Implanting MeV and keV Si ions into the B DSL/SOI structure eliminated the B transient enhanced diffusion normally associated with the keV implant. The buried SiO_2 layer in the SOI substrate isolates the deep interstitials-type extended defects of the MeV implant, thereby eliminating the possibility that these defects getter the interstitial excess induced by the keV Si implant. copyright 1999 American Institute ...

1999-03-01

470

Measurement of the 183 keV Resonance in 17O(p,alpha)14N using a Novel Technique  

Energy Technology Data Exchange (ETDEWEB)

We have developed a novel technique for measurements of low energy (p,alpha) reactions using heavy ion beams and a differentially-pumped windowless gas target. We applied this new approach to study the 183 keV resonance in the 17O(p,alpha)14}N reaction. We report a resonance energy (center-of-mass) of 183.5{+0.1}{-0.4} keV, a resonance strength of 1.70 +/- 0.15 meV, and set an upper limit (95\\% confidence) on the total width of the state of < 0.1 keV. This resonance is important for the 17O(p,alpha)14}N reaction rate, and we find that 18F production is significantly decreased in low mass ONeMg novae but less affected in more energetic novae. We also report the first determination of the stopping power for oxygen ions in hydrogen gas near the peak of the Bragg curve (E=193 keV/u) to be (63+/-1)e-15 eV-cm2.

2007-06-01

471

Experimental research on passive #gamma# scanning system at hot-cell for hull monitoring  

International Nuclear Information System (INIS)

A simulated hull monitoring system based on passive #gamma# ray scanning was set-up in K-01 hot-cell, which consists of a simulated hull basket, a collimator system, a 150 cm"3 HPGe detector and an ORTEC-919 multichannel buffer-computer system. Six different kinds of experimental set-up were established to simulate the variations of #gamma# ray source term distribution (partly concentration) and the variations of matrix density (+46.1%). The experimental results show that the biases of peak area is better than -25.3% for "1"3"7Cs 662 keV #gamma# rays and -18.6% for "1"4"4Ce-"1"4"4Pr 2186 keV #gamma# rays. The hardness of pulse height spectrum is demonstrated to show that the peak area ratio of 2186 keV to 662 keV varies from 380 to 72 when the thickness of lead filter varies form 5 mm to 30 mm. Also studied are the design parameters of collimator system.

472

Annealing behavior of radiation damages in metal-silicides  

International Nuclear Information System (INIS)

The annealing behavior of the radiation damage in epitaxial Pd_2Si and NiSi_2 films on Si, due to the implantation of 100 keV Ar ions, is investigated by using the channeling technique with "4He ions. (U.K.).

476

Reduced boron diffusion under interstitial injection in fluorine implanted silicon  

International Nuclear Information System (INIS)

Point defect injection studies are performed to investigate how fluorine implantation influences the diffusion of boron marker layers in both the vacancy-rich and interstitial-rich regions of the fluorine damage profile. A 185 keV, 2.3x10"1"5 cm"-"2 F"+ implant is made into silicon samples containing multiple boron marker layers and rapid thermal annealing is performed at 1000 deg. C for times of 15-120 s. The boron and fluorine profiles are characterized by secondary ion mass spectroscopy and the defect structures by transmission electron microscopy (TEM). Fluorine implanted samples surprisingly show less boron diffusion under interstitial injection than those under inert anneal. This effect is particularly noticeable for boron marker layers located in the interstitial-rich region of the fluorine damage profile and for short anneal times (15 s). TEM images show a band of dislocation loops around the range of the fluorine implant and the ...

2007-12-01

477

Parity nonconservation in "2"0"7Pb  

International Nuclear Information System (INIS)

Two experiments are currently underway to measure the single-particle weak mixing matrix element for the 1064 KeV transition in "2"0"7Pb. One experiment measures the circular polarization of the 1064 KeV gamma ray emitted from an unpolarized source, while the other experiment measures the forward-backward asymmetry of gamma rays emitted from a polarized source. Analysis of the first set of polarized source data yields an upper limit of 46 eV for the single-particle weak mixing matrix element. copyright 1995 American Institute of Physics.

478

Measurement of M shell X-ray production cross sections and fluorescence yields for the elements in the atomic range 70#<=#Z#<=#92 at 5.96 keV  

International Nuclear Information System (INIS)

Total M X-ray cross sections for 12 elements in atomic range 70#<=#Z#<=#92 were measured at 5.96 keV Mn K X-ray photon energy. The average M shell fluorescence yields (anti #omega#_M) of these elements have also been observed using the presently measured cross section values and the theoretical M shell photoionisation cross section values. (orig.).

479

Investigation of the "1"0"1Mo level and gamma-decay scheme by thermal neutron capture in "1"0"0Mo  

International Nuclear Information System (INIS)

The #gamma#-radiation following thermal neutron capture in "1"0"0Mo has been studied by singles and coincidence measurements. A "1"0"1Mo level scheme has been deduced and is compared with the results of previous (d,p), (n,#gamma#) and "1"0"1Nb decay studies. The existence of the first excited state at 13.51 keV has been confirmed. The present data yield a neutron binding energy of 5398.4 KeV. (Auth.).

1975-03-01

480

Analysis of the chemical transformations induced at the surface of polyacrylonitrile and polymethacrylonitrile films by 5 keV proton beams  

Energy Technology Data Exchange (ETDEWEB)

In this work, the chemical transformations induced by 5 keV protons (10{sup 6} ion cm{sup -2}) at the surface of 0.4 {mu}m polyacrylonitrile and polymethacrylonitrile films are analysed by XPS and IRRAS. Spectroscopic changes in both the polymers are globally similar, the most significant feature being a lower relative concentration of nitrogen with respect to carbon closer to the surface. Quantitatively, this change is more marked in the case of polyacrylonitrile which suggests a direct relation with the hydrogen in {alpha} to the nitrile function.

1999-05-02

481

Irradiation of spices, packaging materials and luncheon to improve the storability of the end product  

International Nuclear Information System (INIS)

Spices and packaging materials were exposed to gamma irradiation at a dose of 10 KGy. Luncheon was prepared with irradiated or non-irradiated spices. Prepared luncheon was packaged in irradiated or non-irradiated packaging materials. Packaged luncheon was treated with 2 KGy. Treated and untreated packaged luncheon were kept in a refrigerator (1-4 Centigrade) for 12 months. Microbiological, nutritive and chemical characteristics of luncheon were evaluated after processing and during storage; whereas, sensory quality was evaluated only after irradiation. Gamma irradiation decreased the microorganisms counts of spices, packaging materials and packed luncheon and increased the shelf-life of packaged luncheon products. No major differences in moisture, protein, fat, ph value, total acidity, lipid peroxide and volatile basic nitrogen were observed ...

482

5.6-nm p"+/n junction formation for sub-0.05-#mu#m PMOSFETs by using low-energy B_1_0H_1_4 ion implantation  

International Nuclear Information System (INIS)

Decaborane (B_1_0H_1_4) cluster ions were implanted into n-Si(100) substrates to fabricate shallow p"+/n junctions. Implant energies of 2 keV, 5 keV, and 20 keV, equivalent to implant energies of the monomer boron ion of 174 eV, 435 eV, and 1.74 keV, respectively, were used at dosages of 1 X 10"1"2 /cm"2 and 1 X 10"1"3 /cm"2. The implanted samples were then subjected to activation annealing at 800 .deg. C, 900 .deg. C, and 1000 .deg. C for 10 s. By using secondary ion mass spectrometry (SIMS) depth profiles, we determined that the depth of the shallow junction (D_s) at a dosage of 1 X 10"1"3 /cm"2 was in the range 12 nm - 45 nm after annealing at 1000 .deg. C. D_s and transient enhanced diffusion (TED) were greatly reduced at implant energies lower than 5 keV, but thermal diffusion (TD) smoothly decreased. In particular, TED was suppressed in the p"+/n junction implanted at 2 ...

2004-06-01

483

Treatment of uteral cancer by the brake irradiation (25 MeV)  

International Nuclear Information System (INIS)

The method of treatment of uteral cancer by the brake irradiation of 25 MeV betatrone using original devices which promote forming therapeutic figured bunches is presented. The binding of the protective blocks with a special adjusting frame within the aperture of the diaphragm provided for low relative entering dose which is the advantage of high energy irradiation bunch. The use of the forming devices makes it possible to practice individual treatment and decrease the levels of irradiation doses for intact organs and tissues.

485

Statistical cut-off criterion  

International Nuclear Information System (INIS)

... radiation effects human populations low dose irradiation neoplasms radiation

1980-01-01

486

Some comments on BEIR III  

International Nuclear Information System (INIS)

... organizations irradiation radiation doses radiation effects RADIATIONS.

1982-01-01

488

Market trials of irradiated chicken  

Energy Technology Data Exchange (ETDEWEB)

The potential market for irradiated chicken breasts was investigated using a mail survey and a retail trial. Results from the mail survey suggested a significantly higher level of acceptability of irradiated chicken than did the retail trial. A subsequent market experiment involving actual purchases showed levels of acceptability similar to that of the mail survey when similar information about food irradiation was provided.

1998-06-01

492

Food irradiation  

International Nuclear Information System (INIS)

A brief article examines the controversy over food irradiation regarding the wholesomeness of irradiated food, its microbiological safety, loss of vitamins and changes in flavour. The benefits of food irradiation are also outlined including the destruction of certain food-borne pathogens and the prolongation of the shelf-life of food by killing pests and delaying the deterioration process. (UK).

1987-02-01

493

Evaluation of transient dose in conveyor type low dose irradiator  

International Nuclear Information System (INIS)

In conveyor type irradiators, the movement of conveyor and the product boxes is not there until the source is fully in the irradiation position. In case the conveyor system fails the source must automatically be returned to its shielded storage vault. The dose received by the product during the movement of the source from or to the shield becomes significant if the total dose to be received by the product is small. A study has been carried out for evaluating the transient dose received by onions in the POTON irradiator. The results of the study are discussed in this paper. (author)

2003-03-05

496

Conclusions from the last five years of experiments in the field of food irradiation in Hungary  

Energy Technology Data Exchange (ETDEWEB)

AGROSTER Co irradiates food packaging material and some types of spices for the meat industry. The step by step strategy of AGROSTER has been very successful. In the last year, its gamma facility was used as much as possible to irradiate food items. The government of Hungary has recognized the benefit of this technology and has given financial assistance to establish a large commercial gamma irradiator in Budapest.

1988-01-01

498

Antimicrobials in the Management of Post-Irradiation Infection  

Science.gov (United States)

... develops. An alternative approach is the use of non-absorbable antibiot- ics such as polymyxin, neomycin, and bacitracin. ...

2011-05-13