Photodetachment of negative ion beams in the presence of a background gas
Energy Technology Data Exchange (ETDEWEB)
To suppress space charge blowup in an ion beam passing through a photoneutralizer, it is necessary to introduce some background gas. An analysis is presented of the neutralization of a high-energy, >200-keV negative deuterium ion beam, exposed to photodetachment while in the presence of deuterium. With a gas thickness of <0.01 Torr.cm, the neutral fraction in the output beam is found to be about the same as that gotten from the photoneutralizer operating in vacuum. Neutral atom beam injection for plasma heating is discussed.
1987-03-01
International Nuclear Information System (INIS)
A 20-MeV proton accelerator is developed by Proton Engineering Frontier Project (PEFP) at Korea Atomic Energy Research Institute (KAERI). The 20MeV accelerator consists of 50keV proton injector, 3MeV RFQ (Radio frequency Quadrupole), 20MeV DTL (Drift Tube Linac) and 20MeV beam line. The beam profile was measured at the end of the 20MeV beam line with wire scanner. Moreover the beam emittance was calculated from the quad scan method using beam line quadrupole magnets. In this paper, the beam profile measurement results are presented and the emittance measurement from the quad scan method is discussed
2010-10-01
Progress of negative-ion based NBI system for JT-60U
Energy Technology Data Exchange (ETDEWEB)
The operation of the negative ion based NBI system for JT-60U has been progressed since 1996. Most of the efforts in the operation for increasing beam power and energy have been concentrated to get over the troubles, caused by surge energy at the moment of the accelerator break-down, in the ion sources and high voltage power supplies. The ion source for the N-NBI, so far, has accelerated negative ion beams of 14.3 A at 380 keV with deuterium and 18.5 A at 360 keV with hydrogen against the target of 22 A. The neutral beam power injected into JT-60U has already reached 5.2 MW at 350 keV for 0.7 sec with deuterium. (author)
1998-07-01
Negative-ion based NBI system for JT-60U
Energy Technology Data Exchange (ETDEWEB)
A 500 keV negative-ion based NBI system is under construction for NB current drive and plasma core heating in high density plasma in JT-60U. Part of the beamline and the high voltage power supply required for a verification test of an ion source was completed in March 1995. After having done a high potential test of the power supply, the negative-ion generation and acceleration tests started in June 1995 aiming at deuterium beams of 500 keV, 22A. In initial experiment, deuterium negative-ion beams of 410 keV, 6.1A (2.5 MW) for 0.2 sec, so far, have been achieved. This is the world highest D{sup {minus}} current and negative ion beam power. The construction of the total system will be completed by the beginning of 1996, and the beam injection will start in March 1996.
1995-12-31
High resolution alpha-particle spectroscopy using CR-39 plastic track detector
Energy Technology Data Exchange (ETDEWEB)
A technique has been developed for high resolution alpha particle spectroscopy from track length determination in CR-39 plastic. On individual tracks an energy resolution deltaE close to the range straggling limit is obtainable. For 6 MeV alpha-particle deltaE is proportional 35 keV on individual particles and for groups of particles deltaE proportional 20 keV can be achieved using certain data selection criteria. At 100 keV on individual particles deltaE is proportional 20 keV. The analysis requires 1) a knowledge of the track-etch rate (Vsub(T))-range relationship and 2) a theoretical understanding of alpha-particle track structure in CR-39 as a function of particle energy, dip angle and degree of etching. The structure of alpha-particle etched tracks in CR-39 is described and two methods of analysis discussed. Examples are given of the resolution attainable on tracks of alpha-particles as natural ...
1984-06-15
Performance estimates of photoneutralized negative-ion beams
Energy Technology Data Exchange (ETDEWEB)
Recent studies have provided data that make it possible to estimate the efficiency and cost of future beamlines using a chemical oxygen-iodine laser as a neutralizer. These studies indicate that a 400-keV neutral deuterium beam of more than 20 A will operate at an efficiency >60%, with the capital cost of the neutralizer at less than $2/W of neutral beam output. Beamlines of lower current and less energy will operate at poorer efficiencies and higher neutralizer costs per watt of neutral beam. These are estimates. As they are very sensitive to changes in the assumptions from which they were derived, they must be used with some caution. Additional studies are expected to provide more reliable estimates.
1984-11-01
Sparking rates measured on the CRITS RFQ
Energy Technology Data Exchange (ETDEWEB)
During the test of the LEDA injector on the CRITS RFQ, an automatic data acquisition system has been implemented. The purpose was to measure the sparking rate of this CW RFQ. The RF level has some influences on vacuum, but there is no evidence of any reciprocal effect. The raw sparking rate is very difficult to interpret, since burst of sparks bias the statistics. A more convenient and useful interpretation is the number of sparking seconds. At the nominal field level (1.75 Kilp), the sparking-second rate is 0.5 per minute without beam. It strongly depends on the field, with a logarithmic law: 4.5 decade/Kilp. With beam, the sparking rate jumps to 3.0 per minute. As far as tested, it depends neither on the beam current (20 to 80 mA) nor on the field (1.5 to 1.7 Kilp tested). With sparking rates as measured here, one could not hope to build an RFQ that would be free of sparks over a several months continuous operation. Such ...
1998-05-28
Galactic deuterium abundance as a test of cosmological models
Energy Technology Data Exchange (ETDEWEB)
The problem on change of deuterium abundance in the process of galactic evolution (star evolution, supernova explosions, nucleosynthesis in supermassive objects) is considered. It is shown that the observable deuterium quantity in the interstellar medium must correspond to its cosmological abundance. This conclusion is independent of the rate of accretion of intergalactic gas by Galaxy. The effect of hypothetical pregalactic active objects on cosmological deuterium is small. It is poind out that observations of interstellar deuterium in absorbtion at lambda=91.6 cm are significant.
1982-02-01
Lattice parameters and thermal expansion of solid ortho-deuterium
Energy Technology Data Exchange (ETDEWEB)
X-ray results on the lattice parameters, molar volume and thermal expansion coefficients of solid ortho-deuterium for the region from 2 K to the melting point are reported. It is found that the thermal expansion of ortho-deuterium crystals, similarly to parahydrogen is essentially anisotropic near the melting temperature. The vacancy density at the triple point is estimated. Some thermodynamic characteristics of ortho-deuterium are calculated and temperature dependences of heat capacity at constant volume, isothermal compressibility and Gruneisen constant are analyzed.
1984-01-01
Deuterium retention in titanium alloys exposed in PLT
International Nuclear Information System (INIS)
Specimen strips of pure alpha titanium and beta titanium alloy were exposed to a range of up to 46 deuterium plasma discharges in the Princeton Large Torus Tokamak (PLT) under simulated first wall conditions, and the amount of trapped deuterium in these specimens was measured, using carbon as a calibration standard for trapping. The Deuterium Nuclear Microprobe was used to study the total trapped deuterium and the deuterium depth distribution in the exposed materials before and after annealing at 373 and 423"0K. The Scanning Auger Microprobe was used to identify the effects of surface impurities on the deuterium distribution. Results indicate that about 20 to 40% of the incident deuterium was trapped by the surface and about 90% of the trapped deuterium remained in a 20A carbonaceous film deposited during plasma ...
1981-07-01
Mapping strain exerted on blood vessel walls using deuterium double-quantum-filtered MRI
UK PubMed Central (United Kingdom)
A technique is described for displaying distinct tissue layers of large blood vessel walls as well as measuring their mechanical strain. The technique is based on deuterium double-quantum-filtered (DQF)...Full Text Available
1998-04-14
Neutron production in the 120 MeV alpha particle bombardment of deuterium
International Nuclear Information System (INIS)
1971. 111 p. United States Chamberlin, EP Texas Agricultural and
We combine a limited number of accurately measured transition frequencies in hydrogen and deuterium, recent quantum electrodynamics (QED) calculations, and, as an essential additional ingredient, a generalized least-squares analysis, to obtain precise and optimal predictions for hydrogen and deuterium transition frequencies. Some of the predicted transition frequencies have relative uncertainties more than an order of magnitude smaller than that of the g-factor of the electron, which was previously the most accurate prediction of QED.
2005-01-01
Oxygen, hydrogen, and deuterium effects on plasma nitriding of metal alloys
International Nuclear Information System (INIS)
We report the oxygen, hydrogen, and deuterium effects on nitrogen implantation of stainless steel. Oxygen is absorbed on the surface creating a potential barrier and diminishing the nitrogen retention. Deuterium removes more oxygen from the surface than hydrogen, augmenting the nitrogen chemical potential and yielding faster nitrogen diffusion into the bulk material.
2006-04-01
Cosmological implications of helium and deuterium abundances on Jupiter and Saturn
Energy Technology Data Exchange (ETDEWEB)
The determination of relative abundances of helium and deuterium in Jupiter and Saturn provides estimates of the primordial abundances of these elements. The values so inferred can be compared with theoretical predictions of the standard model of the big-bang theory as a test of the model and suggest either that deuterium is more efficiently consumed in subsequent nucleosynthesis than hitherto assumed, or that the standard big-bang model should be revised in order for there to have been less production of primordial helium.
1983-03-17
Particle emission from low energy nuclear reactions in solids. Preliminary results
Energy Technology Data Exchange (ETDEWEB)
TiH{sub 2} and TiD{sub 2} thick targets were bombarded with 100 to 200 keV protons or deuterons. Evidence for nuclear reactions was obtained by means of a surface barrier particle detector. Deuteron irradiation of TiD{sub 2} produced these observations: copious {approx}2.5 MeV neutrons and {approx}3 MeV protons from direct D-D reactions; gamma rays from p,{gamma} and n,{gamma} reactions; {approx}14 MeV protons from the secondary d({sup 3}He, p){alpha} reaction; and a signal between {approx}6-12 MeV that Kasagi et al. has tentatively identified as protons from the fusion of three deuterium nuclei. However, this signal has in it a strong interference signal from either neutrons or gamma rays that directly deposit energy in the detector. This interference spectra was measured by placing a thick absorber in front of the detector that stops up to 20 MeV protons, but not gamma rays or neutrons. More experiments must be done before we can confirm or ...
2000-07-01
Production of secondary Deuterium in the atmosphere at various latitudes
Energy Technology Data Exchange (ETDEWEB)
Secondary deuterium in the atmosphere are produced in interactions by primary cosmic rays. The shape of their energy spectrum depends on the primary cosmic ray spectrum incident at the top of the atmosphere. At high energies, the spectral shape depends on the primary spectrum of helium and heavy nuclei. However, at very low energies, specially below the geomagnetic cut-off, the spectral shape depends on the evaporation and recoil processes and hence almost independent of the spectral shape of the primary radiation. It is undertaken a calculation of the secondary deuterium spectrum at small atmospheric depths at various latitudes and the results will be presented.
1995-09-01
Post-mortem measurements of fuel retention at JET with MKII-SRP divertor
International Nuclear Information System (INIS)
The deuterium inventory at JET after 2001-2004 operational campaign has been determined using nuclear reaction analysis (NRA) and secondary ion mass spectrometry (SIMS). A full poloidal set of divertor tiles and a set of outer poloidal limiter (OPL) tiles were analysed providing an estimation for the total deuterium retention of about 66 g. Deuterium is trapped mainly at the inner divertor on horizontal target tile and at the inner divertor louvre area where ?60% of the trapped D is found. The long-term D retention is ?4% of the total D input.
2009-06-15
Embedded systems for vacuum control at PEFP
International Nuclear Information System (INIS)
Development of a front end system for a high energy proton accelerator is in progress at Korea Atomic Energy Research Institute (KAERI) for basic science and industrial applications. The proper vacuum components has been installed and operated successfully between ion source and RFQ. The reliable operation of the accelerator has been completed at vacuum system in the high and ultra high vacuum range under operating conditions. Proper control system for the vacuum instruments, based on PC operated by Windows, has been designed and constructed by control group at PAL. As PC operated by windows with inherent instability does not proper, embedded system can be replaced for reliable operation system, such as VME system operated by vxWorks.
2005-05-26
Review of JT-60U experimental results from February to October, 1999
International Nuclear Information System (INIS)
In 1999, the plasma parameters of reversed shear (RS) plasmas had been extended in 1) DT-equivalent fusion power gain Q_D_T"e"q - 0.5 (n_D(0)#tau#_ET_i(0) - 4x10"2"0 m"-"3#centre dot#keV#centre dot#s) for 0.8 s and 2) full non-inductive current drive with 80% of the bootstrap current fraction. Physics of the internal transport barriers (ITBs) in RS plasmas, including the energy transport and the formation of ITB, were extensively studied. A nearly full current drive (92% non-inductively) was obtained with negative ion based neutral beam (NNB) injection (360 keV, 3.4 MW) in a high #beta#_p H-mode plasma (I_p=1.5 MA, B_T=3.7 T, q_9_5=4.2) with high plasma performance (#beta#_N=2.4 and H_8_9=2.56). Rise in the central electron temperature (T_e - 9 keV) resulted in the current drive efficiency #eta#_C_D of NNB reached 1.3x10"1"9 A/W/m"2, the highest for the neutral beam current drive. As for the H-mode plasmas, decrease in the pedestal ion ...
1994-06-01
Long pulse extraction of deuterium negative ion beams from the Kamaboko ion source
Energy Technology Data Exchange (ETDEWEB)
Operation at ITER specifications of the Kamaboko III ion source for 1000 second pulses of deuterium negative ion beams is underway on the MANTIS test stand. Efficient production of negative ions at low arc power requires injection of cesium into the source, temperature control of the plasma grid, and a period of conditioning of several days. Two different concepts of temperature regulated plasma grids are currently being tested. (author)
1998-07-01
Accommodation coefficients of helium, neon, argon, hydrogen and deuterium on graphitized carbon
Energy Technology Data Exchange (ETDEWEB)
The thermal accommodation coefficients of helium, neon, argon, hydrogen and deuterium have been measured in the temperature range of 77-340 K on the surface of a graphitized carbon filament. The dependence of the accommodation coefficient upon the molecular weight as well as the temperature of measurement, and the conversion from orthohydrogen to parahydrogen, have been discussed.
1987-07-30
Solid deuterium centrifuge pellet injector
Energy Technology Data Exchange (ETDEWEB)
Pellet injectors are needed to fuel long pulse tokamak plasmas and other magnetic confinement devices. For this purpose, an apparatus has been developed that forms 1.3-mm-diam pellets of frozen deuterium at a rate of 40 pellets per second and accelerates them to a speed of 1 km/s. Pellets are formed by extruding a billet of solidified deuterium through a 1.3-mm-diam nozzle at a speed of 5 cm/s. The extruding deuterium is chopped with a razor knife, forming 1.3-mm right circular cylinders of solid deuterium. The pellets are accelerated by synchronously injecting them into a high speed rotating arbor containing a guide track, which carries them from a point near the center of rotation to the periphery. The pellets leave the wheel after 150/sup 0/ of rotation at double the tip speed. The centrifuge is formed in the shape of a centrifugal catenary and is constructed of high strength KEVLAR/epoxy composite. ...
1982-01-01
Fluence- and exposure-to-dose conversion for human whole-body gamma irradiation
International Nuclear Information System (INIS)
... kev range 10-100 kev range 100-1000 man mev range 01-10 personnel
1978-01-01
International Nuclear Information System (INIS)
Natural convection of vaporizing Deuterium at 25 K transports the heat generated in the moderator cell of the cold neutron source to a He cooled condenser. The thermohydraulics of this thermosiphon were precalculated and the results verified by experiments in a 1:1 model using D_2 as fluid. The experimental results show that the thermosiphon operates stable. The demanded liquid content of the cell as well as wall temperatures below 50 K can be ensured by a proper design of the cell outlet flow geometry. A 7 min. loss of cryogenic power results in transient temperatures of the cell wall of not more than 300 K.
1991-08-01
Possible influence of vacuum polarization on Q/sub 1//sub //sub s/ in muon catalyzed D-T fusion
Energy Technology Data Exchange (ETDEWEB)
The vacuum polarization splitting of the M-shell states in muonic hydrogen can have a profound influence on the muonit de-excitation cascade in deuterium and tritium targets. The cascade also shows sensitive dependence on the precise rate of transfer processes between certain excited muonic deuterium and tritium atoms. Recent experimental data, where a much greater population of the (d..mu..) qs state (1/sub 1//sub //sub s/) was found than previously predicted, can be explained if the transfer rates from the (d..mu..) M-shell are assumed to be strongly suppressed.
1988-12-27
Negative charges in liquid hydrogen and deuterium
Energy Technology Data Exchange (ETDEWEB)
The temperature and pressure dependence of the mobilities of negative charges injected into liquid hydrogen and deuterium have been measured. The authors propose the existence of two types of charge carriers in liquid parahydrogen. One is a bubble with an electron inside while the other has higher mobility. Relaxation of the current through liquid hydrogen was observed. It is suggested that in liquid and solid hydrogen under {beta}-irradiation neutral complexes are created which can trap the negative charges and have a lifetime of about 10 hours. 6 refs., 5 figs.
1992-11-01
Core simulations using actual detector readings for a Canada deuterium uranium reactor
This paper reports that, to obtain better simulation results for a Canada deuterium uranium (CANDU) reactor operation, a new simulation method is developed that uses actual detector readings as a correction factor. Detector readings from a CANDU reactor are used to correct the calculated flux distribution during core calculation iterations. A suitable function is found to describe the relationship between the detector flux and the fluxes of mesh points around the detector. The new simulation method is tested by performing numerical calculations for the Wolsung reactor (a CANDU-600). The results show that the new method predicts the core state more accurately with fewer iterations.
1991-02-01
International Nuclear Information System (INIS)
The total interaction cross sections (#sigma#_t) of some sugars and amino acids and five elements: lithium, carbon, oxygen, aluminium and calcium have been measured for 6.4 keV, 13.95 keV, 14.4 keV, 17.74 keV, 24.14 keV, 30.8 keV, 35 keV, 59.54 keV, 81 keV, 122 keV and 136 keV photons in a narrow beam good geometry set up, by using high resolution detectors such as a Si-PIN diode detector and a high purity germanium detector. The #sigma#_t values have been used in a matrix method to evaluate the effective atomic numbers Z_e_f_f of the samples from their effective atomic cross sections #sigma#_a. The effective atomic cross section of a sample #sigma#_a is the total interaction cross section divided by the total number of atoms of all types in it. Further, a ...
2007-09-28
Intense negative-ion beams extracted from an ECR ion source coupled to a charge exchange canal
Energy Technology Data Exchange (ETDEWEB)
Electron cyclotron resonance (ECR) ion sources possess several advantages over ion sources conventionally used for injectors of electrostatic accelerators: improved reliability, high efficiency, simplicity, and the capability of generating bright, high-current ion beams. We have adapted a high-current ECR source originally developed as an injector for a CW RFQ proton linac to serve as a source of intense negative-ion beams for the Tandem Accelerator Superconducting Cyclotron (TASCC) facility at Chalk River. The range of ion species of the source has been extended from H{sup 1+} alone up to Bi{sup 1+}, with both gaseous and nonvolatile feeds. Two intense negative-ion beams of He{sup -} and O{sup -} have been generated so far with the source coupled to a standard charge-exchange canal. We foresee no major problems generating a broad range of negative ions with this system. (author)
1993-07-01
Intense negative-ion beams extracted from an ECR ion source coupled to a charge exchange canal
International Nuclear Information System (INIS)
Electron cyclotron resonance (ECR) ion sources possess several advantages over ion sources conventionally used for injectors of electrostatic accelerators: improved reliability, high efficiency, simplicity, and the capability of generating bright, high-current ion beams. We have adapted a high-current ECR source originally developed as an injector for a CW RFQ proton linac to serve as a source of intense negative-ion beams for the Tandem Accelerator Superconducting Cyclotron (TASCC) facility at Chalk River. The range of ion species of the source has been extended from H1+ alone up to Bi1+, with both gaseous and nonvolatile feeds. Two intense negative-ion beams of He- and O- have been generated so far with the source coupled to a standard charge-exchange canal. We foresee no major problems generating a broad range of negative ions with this system. (author)
1993-09-22
Design of APhF-IH Linac for a Compact Medical Accelerator
The design of a small injection linac for a compact medical synchrotron is discussed. The linac design is based on interdigital H-type (IH) drift-tube structure with alternative phase focusing (APhF). A high acceleration rate and an absence of magnetic lenses inside drift-tubes reduce the cost and length of APhF-IH linac in comparison with HIMAC linac based on Alvarez structure with magnet quadrupoles inside drift-tubes. To reduce effects of emittance growth, the RFQ structure is used in front of the APhF linac. In such linac layout, the current transmission of a carbon beam can reach up to 90-100%. In this report, the basic parameters of whole linac are presented, while the design of APhF structure is considered in details. Two reference designs of 4 MeV/u 200 MHz APhF linacs with different voltage distributions along the whole tank have been generated and analyzed numerically. For the first design, a constant voltage distribution along the tank is assumed. The ...
2003-01-01
Complex Spatio-Spectral Structure of Diffuse X-Ray emission in the ...
SN 1987A: Soft X-Ray Intensity Ratio. 2002-12 to 2000-12. 2005-7 to 2002-12. Contours: 2002-12. (0.5 2 keV). (0.5 2 keV). Contours: 2005-7 ...
Electron capture decay of sup 203 Pb
Energy Technology Data Exchange (ETDEWEB)
Intensities of {gamma}-transitions emerging from the EC decay of {sup 203}Pb were measured precisely. The obtained relative {gamma}-intensities are 100%(279.2keV), 4.14+-0.08%(401.3keV) and 0.932+-0.022%(680.5keV). The 279.2 and 680.5keV level feeding {beta}-branching ratios were deduced to be 95.3+-0.1 and 4.7+-0.1% respectively. {sup 203}Pb is suggested for calibration purposes. (author).
1989-01-01
8"+ isomers in N=48 isotones and E2 polarization charges
International Nuclear Information System (INIS)
... charges energy levels gamma spectra half-life isomeric nuclei kev range
1972-05-01
Some fundamental factors in quantitative analysis by ion microanalyzer
International Nuclear Information System (INIS)
In analysis of hydrogen in metals and alloys by SIMS, control of the hydrogen blank mainly due to residual gases is a persistent problem. Contrarity, this problem becomes less important in case of deuterium analysis. The prescribed amounts of deuterium were introduced into a pure titanium and a beta-titanium alloy (Ti- 6.6wt%Fe) by the gas reaction method. Intensities of the various secondary ions sputtered from each sample were measured by the Hitachi Ion Microanalyzer with primary ions of Ar"+. Energy distributions of the various secondary ion species were measured with the energy window of about 15eV width. The effects of oxygen gas pressure in the target chamber and the bulk deuterium concentration on the shape of energy distribution curves are discussed. For all samples, intensity of D"- ions is higher than that of D"+ ions, especially at higher energy ranges. With increasing the deuterium ...
Structure of the triplet of low-lying states in sup 101 Mo
Energy Technology Data Exchange (ETDEWEB)
The properties of the triplet of low-lying states in {sup 101}Mo have been studied through spectroscopy of the {gamma} radation following thermal neutron capture in {sup 100}Mo and {beta}-decay of {sup 101}Nb and through a measurement of the proton angular distributions in the {sup 100}Mo(d, p) reaction with 14 MeV deuteron energy. The half-lives of the 13.5 keV state and the 57.0 keV 5/2{sup +} state have been measured as 226(7) and 133(7) ns, respectively. These values and the quadrupole/dipole mixing ratios of the 13.5 keV and 43.5 keV transitions yield spin and parity 3/2{sup +} for the 13.5 keV level. The E2 components in the 13.5 (3/2{sup +}->1/2{sup +}) and 43.5 keV (5/2{sup +}->3/2{sup +}) transitions are {le} 8x10{sup -4} and 54(9)%, respectively. The possibility of an additional state near to the 57.0 keV level is discussed. ...
1991-06-01
Structure of the triplet of low-lying states in "1"0"1Mo
International Nuclear Information System (INIS)
The properties of the triplet of low-lying states in "1"0"1Mo have been studied through spectroscopy of the #gamma# radation following thermal neutron capture in "1"0"0Mo and #beta#-decay of "1"0"1Nb and through a measurement of the proton angular distributions in the "1"0"0Mo(d, p) reaction with 14 MeV deuteron energy. The half-lives of the 13.5 keV state and the 57.0 keV 5/2"+ state have been measured as 226(7) and 133(7) ns, respectively. These values and the quadrupole/dipole mixing ratios of the 13.5 keV and 43.5 keV transitions yield spin and parity 3/2"+ for the 13.5 keV level. The E2 components in the 13.5 (3/2"+#->#1/2"+) and 43.5 keV (5/2"+#->#3/2"+) transitions are #<=# 8x10"-"4 and 54(9)%, respectively. The possibility of an additional state near to the 57.0 keV level is discussed. IBFM/PTQM calculations, taking into ...
Study of Zircaloy-2 corrosion in high temperature water using ion beam methods
Energy Technology Data Exchange (ETDEWEB)
Experiments have been carried out in water at 355 C to study transport of oxygen and hydrogen (as deuterium) in growing corrosion films. Composition of the films was also examined in 2.9 Mev and 3.9 Mev /alpha/-particle backscattering experiments. Corrosion occurs predominantly by oxygen diffusion through the film via grain boundary or similar short circuit diffusion paths, to form fresh oxide at the oxide metal interface. Increasing grain size within thick pre-breakaway films contributes to a decrease in diffusivity. The rate transition results from the generation of new diffusion pathways in previously protective oxide. Unexpectedly high concentrations of deuterium were observed. 26 refs.
1981-10-01
Overview of long-term fuel inventory and co-deposition in castellated beryllium limiters at JET
International Nuclear Information System (INIS)
Morphology of castellated Be tiles from the belt limiter exposed to the JET plasma for 56,000 s was examined on both sides of castellated grooves, on plasma-facing and side surfaces of the tiles. The essential results are (i) deuterium retention in the castellated grooves and in other locations is associated with co-deposition of carbon; (ii) the decay length of deposition in the castellation is around 1.5 mm; (iii) no deuterium is detected in bulk Be; (iv) bridging of gaps by molten beryllium occurred but gaps were not filled with Be; (v) on side surfaces of the tiles the formation of BeO layer was detected at a distance of 20 mm and more from the plasma-facing surface. The consequences for a long-term operation of a reactor-class device with several different plasma-facing materials are addressed.
2009-04-30
Energy Technology Data Exchange (ETDEWEB)
The crystal structure of Ca{sub 2}RuD{sub 6} has been determined by neutron powder diffraction: space group Fm3m, K{sub 2}PtCl{sub 6} structure, as found for other hexahydride salts of group 8 metals with alkaline earth or lanthanide counter ions. No structural phase transition was observed between 340 K and 50 K. The deuterium nuclear quadrupole coupling constant, 54.7 kHz, leads to an ionic character of the Ru-D bond of 76%. The known trends in the behaviour of A{sub 2}MH{sub 6} salts are interpreted in terms of the ionization energies of the cation and the central metal atom.
2008-07-28
British Library Electronic Table of Contents (United Kingdom)
The crystal structure of Ca2RuD6 has been determined by neutron powder diffraction: space group Fm3m, K2PtCl6 structure, as found for other hexahydride salts of group 8 metals with alkaline earth or lanthanide counter ions. No structural phase transition was observed between 340K and 50K. The deuterium nuclear quadrupole coupling constant, 54.7kHz, leads to an ionic character of the Ru-D bond of 76%. The known trends in the behaviour of A2MH6 salts are interpreted in terms of the ionization energies of the cation and the central metal atom.
2008-01-01
Ion temperature anisotropy in high power helium neutral beam fuelling experiments in JET
Energy Technology Data Exchange (ETDEWEB)
During helium beam fuelling experiments in JET, distinctive anisotropic features have been observed in the velocity distribution function describing both fast and thermal alpha particle populations. During the initial fuelling phase the central helium ion temperature observed perpendicular to the magnetic field is higher than the central electron temperature, while the central helium ion temperature observed parallel to the magnetic field is lower than or equal to the central electron temperature. In order to verify temperature measurements of both perpendicular and parallel lines of sight, other independent methods of deducing the ion temperature are investigated: deuterium ion temperature, deuterium density, comparison with neutron rates and profiles (influence of a possible metastable population of helium). 6 refs., 7 figs.
1994-07-01
Energy Technology Data Exchange (ETDEWEB)
The effect of varying pD(11-13,7) on the reaction of hydrogen with (Co/sup 11/(CN)/sub 5/)/sup 3/- in deuterium oxide has been studied by using infrared spectroscopy to determine the ratio of (Co/sup 111/(CN)/sub 5/X)/sup 3/- (X=H,D) in the solids precipitated from the steady state under hydrogen. The results show that the uptake of hydrogen does not liberate a free proton and that the rate of (Co/sup 111/(CN)/sub 5/H)/sup 3/- -D/sub 2/,0 exchange increases with pD but becomes pD independent at pD 7 greater than 13,5.
1982-01-01
Hydrogen absorption behavior of Zr-2.5Nb pressure tubes in Wolsung Unit 1
Energy Technology Data Exchange (ETDEWEB)
The deuterium uptake behavior of Zr-2.5Nb pressure tubes in Wolsung Unit 1 was analyzed in terms of longitudinal location, operation time, and coolant temperature. The results were compared with those obtained from Canadian CANDU reactors. The amount of deuterium uptake was higher at the outlet part than at the inlet part and was also higher when subjected to a longer operation time and a higher coolant temperature. The hydrogen uptake of Zr-2.5Nb in a hydrogen gas atmosphere was dependent on the microstructure of the alloy. The aged Zr-2.5Nb consisting of {alpha}-Zr and {beta}-Zr phases. The hydrogen in the alloy decreased the rate of oxidation. This could be explained in terms of the cathodic controlled reaction of Zr-2.5Nb oxidation. (author)
1998-08-01
Effects of sawtooth crashes on beam ions and fusion product tritons in JET
Energy Technology Data Exchange (ETDEWEB)
The effect of a sawtooth crash on the radial distribution of the slowing down fusion product tritons and on beams ions, is examined with measurements of the 2.5 MeV and 14 MeV neutron emission line-integrals before and after sawtooth crashes. In deuterium discharges, the 14 MeV neutron production was wholly attributable to burnup of the 1 MeV fusion product tritons from d-d fusion. The local emissivity of 14 MeV neutrons, and hence of the profile of thermalizing tritons, is shown to be only weakly affected by crashes in the discharges studied. This is in contradiction with the apparent behaviour of injected beam ions as deduced from a study of the considerable changes in local emissivity of the 2.5 MeV neutrons. Nevertheless, the behaviour of the fusion product tritons is consistent with the scaling of the beam injected deuterium. 1 ref., 6 figs.
1994-07-01
Detached divertor plasmas in JET
Energy Technology Data Exchange (ETDEWEB)
In simulations with high radiated power fractions, it is possible to produce the drop in ion current to the divertor targets typical of detached plasmas. Despite the fact that these experiments are performed on beryllium target tiles, radiation from deuterium and beryllium cannot account for the measured power losses. The neutral deuterium levels in the SOL in these plasmas are higher than the model predicts. This may be due to leakage from the divertor or to additional wall sources related to the non-steady nature of these plasmas. In contrast, a surprisingly high level of carbon is present in these discharges; higher even than would be predicted are the divertor target tiles pure carbon. This level may well be large enough to produce the measured radiation. (authors). 6 refs., 2 figs., 1 tab.
1994-07-01
Atmospheric proton and deuterium energy spectra determination with the MASS2 experiment
Energy Technology Data Exchange (ETDEWEB)
The energy spectra of atmospheric-secondary protons and deuterium nuclei have been measured during the September 23, 1991, balloon flight of the NMSU/Wizard - MASS2 instrument. The apparatus was launched from Fort Sumner, New Mexico. The geomagnetic cutoff at the launch site is about 4.5 GV/c. The instrument was flown for 9.8 hours at an altitude of over 100,000 feet. Particles detected below the geomagnetic cutoff have been produced mainly by the interactions of the primary cosmic rays with the atmosphere. The measurement of cosmic ray energy spectra below the geomagnetic cutoff provide direct insights into the particle production mechanism and allows comparison to atmospheric cascade calculations.
1995-09-01
International Nuclear Information System (INIS)
A semi-empirical relation which can be used to determine the total attenuation cross sections of samples containing H, C, N and O in the energy range 145-1332 keV has been derived based on the total attenuation cross sections of several sugars, amino acids and fatty acids. The cross sections have been measured by performing transmission experiments in a narrow beam good geometry set-up by employing a high-resolution hyperpure germanium detector at seven energies of biological importance such as 145.4 keV, 279.2 keV, 514 keV, 661.6 keV, 1115.5 keV, 1173.2 keV and 1332.1 keV. The semi-empirical relation can reproduce the experimental values within 1-2%. The total attenuation cross sections of five elements carbon, aluminium, titanium, copper and zirconium measured in the same experimental set-up at the energies mentioned ...
2006-09-28
Surface intermediates in selective olefin oxidation and ammoxidation
Energy Technology Data Exchange (ETDEWEB)
An investigation of the mechanism of the oxidation and ammoxidation of propylene was made. The products of the above reactions were acrylonitrile and acrolein for ammoxidation and oxidation, respectively. Also, the ammoxidation and oxidation of allyl alcohol, allyl amine, and their allylic deuterium substituted analogues was studied. It was concluded that oxidation and ammoxidation of propylene have the same rate determining step. Other conclusions about the reaction intermediates were also made.
1983-02-01
International Nuclear Information System (INIS)
By the methods of the angular distribution of photon annihilation, time distribution of photon annihilation, photoluminescence spectroscopy, Fourier IR-spectroscopy, atomic force microscopy the detail information on relation of the structural and physical properties of the porous nano-structures is obtained. Study of pores sizes in a different nano-porous materials, such as the porous silicon, porous anode aluminium oxide, porous solids exposed to light atoms ion implantation (hydrogen, deuterium, helium) is carried out.
2003-09-15
Multiquark states in nuclei and the deep inelastic scattering
International Nuclear Information System (INIS)
Based on a hypothesis of multiquark states in nuclei, the nucleus structure functions are considered and the results are compared with experiment. It is shown that the multiquark state contributions are sufficiently high (Up to 20% in deuterium and 40% in iron) and must possess a greater, than in a nucleon, sea of quark-antiquark pairs. Also the comparison with the cumulative particle production cross sections is performed. The predictions are given for a further experimental test of that hypothesis.
Energy Technology Data Exchange (ETDEWEB)
The catalytic properties of molybdena-alumina catalysts reduced in hydrogen were studied in the function of the reduction temperature, i.e. in the function of the extent of reduction. The deuterium exchange reaction of benzene was used as model catalytic reaction. It was concluded that the reaction rate constant and the multiplicity factor decreased with the extent of reduction parallel with the change in the extent of dehydroxylation of the catalysts. (orig.)
1994-02-01
Ab initio calculations in a uniform magnetic field using periodic supercells
Energy Technology Data Exchange (ETDEWEB)
We present a formulation of ab initio electronic structure calculations in a finite magnetic field, which retains the simplicity and efficiency of techniques widely used in first principles molecular dynamics simulations, based on plane-wave basis sets and Fourier transforms. In addition we discuss results obtained with this method for the energy spectrum of interacting electrons in quantum wells, and for the electronic properties of dense fluid deuterium in a uniform magnetic field.
2003-10-21
A Theory of Laser Induced Nuclear Reaction in Single Atoms
International Nuclear Information System (INIS)
An 'electron-bridge' mechanism of nuclear reaction in an atom or ion by ultra-intense laser fields is presented. A preliminary estimate of the intensity dependence of the rate of disintegration reaction of deuteron nucleus in deuterium atom is made for 800 nm laser fields. For intensities below 5x1021 W/cm2, the rate of disintegration by the 'electron-bridge' mechanism is found to be small, but it rises sharply and becomes large already for ?1022 W/cm2.
2010-02-02
The differential cross section measurements for /sup 241/Am, /sup 242m/Am and /sup 243/Am are reviewed in the energy range from 0.5 eV to 10 keV. Parameters extracted from resonance analysis, such as the neutron strength function, the average level spacing, the average capture and fission widths, are compared for the various measurements. The average capture and fission cross sections from 100 eV to 10 keV are directly compared. The status of the data set is discussed with suggestions for further measurements. 24 references.
1978-11-16
The investigations on K and L X-ray fluorescence parameters of gold compounds
British Library Electronic Table of Contents (United Kingdom)
The study aimed to determine the chemical effects on the K and L X-ray intensity ratios and the K and L X-ray production cross sections for gold compounds. The K shell fluorescence yields and L shell average yields were also investigated. The samples were excited by 59.5keV ?-rays from an 241Am annular radioactive source and 123.6keV ?-rays from a 57Co annular radioactive source. K and L X-rays emitted from samples were counted by an Ultra-LEGe detector with a resolution of 0.150keV at 5.9keV. The experimental values were compared with theoretical, the semi-empirical and other experimental values.
2010-01-01
The Canonical Seyfert Spectrum: The Implications of OSSE ...
... In a HEAO 1 study of active galaxies, principally Seyfert 1s, in the 2, 165 keV energy range, Rothschild et al. ... As discussed by Rothschild et al. ...
2011-05-14
On penetration effect in M1 component of 70.45 keV #gamma#-transition in "1"7"7Ta
International Nuclear Information System (INIS)
... gamma radiation l conversion m conversion mev range 10-100 mixing ratio
1987-04-14
Electric and magnetic dipole transitions in odd-proton rare-earth nuclei
International Nuclear Information System (INIS)
... gamma cascades kev range 10-100 lifetime lutetium 171 lutetium 173 lutetium
1972-05-01
Penetration effect in the M1 component of "1"7"7Ta #gamma#-transition with energy of 70.45 keV
International Nuclear Information System (INIS)
The magnetic #beta#-spectrometer of the #pi# #sq root#2 type with 0.07% pulse resolution is used to measure the intensities of interval conversion electrons on L- and M-subshells of 70.45 keV "1"7"7 Ta gamma-transition. The results are analyzed and the values of mixing parameter #sigma#(E2/M1) and penetration parameter #lambda# are obtained.
Improved FNAL linac beam choppers
Energy Technology Data Exchange (ETDEWEB)
A discussion is presented of the 750-KeV chopper experience with both proton and negative ion beams and the ability of these systems to tailor the Linac beam to the diverse requirements of its users; normal accelerator injection, neutron therapy beam, and electron cooling experiments. This flexibility plus a cleaner beam pulse, improved thyratron operation, and mechanical modularity are the results of recent improvements. Additional benefits have been increased reliability and ease of service to the 750-KeV chopper. 3 refs.
1981-06-01
Gamma-ray spectra from neutron capture on /sup 87/Sr
Energy Technology Data Exchange (ETDEWEB)
The gamma-ray spectrum following neutron capture on /sup 87/Sr was measured at 3 neutron energies: E/sub n/ = thermal, 2 keV, and 24 keV. Gamma rays were detected in a three-crystal Ge(Li)-NaI-NaI pair spectrometer. Gamma-ray intensities deduced from these spectra by spectral unfolding are presented.
1981-07-01
Evaluation of adhesive plasters by radionuclide X-ray fluorescence analysis
International Nuclear Information System (INIS)
A radiometric method was elaborated for surface density determinations of the adhesive layer of plasters by radionuclide X-ray fluorescence using the 17.47 keV bremsstrahlung of "1"4"7Pm/Mo. The bremsstrahlung line excites the 8.63 keV characteristic K#alpha# line of Zn contained in the adhesive layer of the plaster as a filling material in the form of ZnO. In homogeneous adhesive layers the Zn content is proportional to surface density. (author).
1976-01-01
Observed energy dependence of Fano factor in silicon at hard X-ray energies
Energy Technology Data Exchange (ETDEWEB)
An experimental evaluation of the Fano factor F in silicon at hard X-ray energies (5.9-136.5 keV) has been performed by means of a low-noise, high charge collection efficiency silicon drift detector with on-chip electronics. A dependence of F from the detector temperature as well as from the energy of the X-ray photons has been found. Assuming a pair creation energy equal to 3.64 eV, at +20 deg. C the F factor was observed to vary from 0.124{+-}0.006 at 5.9 keV up to 0.159{+-}0.002 at 122 keV. At -35 deg. C, the change of F with respect to the photon energy was less remarkable but nevertheless statistically significant, from 0.123{+-}0.002 at 5.9 keV up to 0.134{+-}0.001 at 122 keV. To our knowledge, the present results represent the first experimental evidence of an energy dependence of the Fano factor in silicon at hard X-ray energies.
1999-03-01
0--30 keV low-energy focused ion beam system
Energy Technology Data Exchange (ETDEWEB)
Low-energy focused ion beam (FIB) is a useful tool for shallow doping, gas-assisted etching, and other uses to minimize substrate damage in semiconductor device fabrication. The possibility to form a finely FIB of low energy under 1 keV was suggested in the investigations on the retarding mode in electron optical systems. The abilities of the simplest type of retarding mode FIB column are examined here. The optical properties are calculated for the corresponding model and some images are observed with Ga/sup +/ ion beams <0.3 ..mu..m in diameter for beam energies, 10, 5, and 1 keV, using a retarding mode one-lens FIB system. 1-keV and 100-eV Ga/sup +/ FIB was implanted to Ga/As substrate, and the defects are analyzed by deep-level transient spectroscopy. The defect concentration for 100 eV was < (1)/(5) that for 1000 keV.
1988-05-01
0--30 keV low-energy focused ion beam system
International Nuclear Information System (INIS)
Low-energy focused ion beam (FIB) is a useful tool for shallow doping, gas-assisted etching, and other uses to minimize substrate damage in semiconductor device fabrication. The possibility to form a finely FIB of low energy under 1 keV was suggested in the investigations on the retarding mode in electron optical systems. The abilities of the simplest type of retarding mode FIB column are examined here. The optical properties are calculated for the corresponding model and some images are observed with Ga"+ ion beams <0.3 #mu#m in diameter for beam energies, 10, 5, and 1 keV, using a retarding mode one-lens FIB system. 1-keV and 100-eV Ga"+ FIB was implanted to Ga/As substrate, and the defects are analyzed by deep-level transient spectroscopy. The defect concentration for 100 eV was < (1)/(5) that for 1000 keV.
International Nuclear Information System (INIS)
In the High Flux Reactor (HFR) at Grenoble a new horizontally arranged cold neutron source will be installed that uses liquid deuterium (D_2) as the moderator for cold neutrons. This cold source should provide a high neutron flux, it should be simple in design, and be characterized by high reliability and by safe operation. A high neutron flux calls for installation of the cold source near the HFR core and good moderation requires a D_2 volume of #DELTA#5 litres. Hence, the moderator, contained in a horizontally arranged cylindrical cell of 21 cm diameter and 20 cm length, is installed at the end nearest to the core of a horizontal beam tube of roughly 4.5 m length with an inner diameter of only 23 cm (Fig. 1). The HFR will be equipped with a second cold neutron source. The installation in the existing horizontal beam tube together with the amount of heat released determined the problems to be solved: the liquid content of the moderator cell must be high; the ...
Energy Technology Data Exchange (ETDEWEB)
This project of law concerns an additional protocol to the agreement of warranties signed on September 22, 1998 between France, the European atomic energy community and the IAEA. This agreement concerns the declaration of all information relative to the R and D activities linked with the fuel cycle and involving the cooperation with a foreign country non endowed with nuclear weapons. These information include the trade and processing of nuclear and non-nuclear materials and equipments devoted to nuclear reactors (pressure vessels, fuel loading/unloading systems, control rods, force and zirconium tubes, primary coolant pumps, deuterium and heavy water, nuclear-grade graphite), to fuel reprocessing plants, to isotope separation plants (gaseous diffusion, laser enrichment, plasma separation, electromagnetic enrichment), to heavy water and deuterium production plants, and to uranium conversion plants. (J.S.)
2002-10-01
Development of the Regulation Concept for a Fusion Reactor
International Nuclear Information System (INIS)
Fusion energy has been studied in many countries such as U.S., France, Japan, Korea etc. Because it would provide much more energy for a given weight of fuel than any technology currently in use, and the fuel itself (primarily deuterium) exists abundantly in the Earth's ocean. Nuclear fusion reactor uses tritium and deuterium as fuel while nuclear fission reactor uses uranium and plutonium as fuel. Besides, inherent design characteristics and driving condition of nuclear fusion reactor is different from those of nuclear fission reactor. Therefore, we cannot apply the regulation rules of nuclear fission reactor to nuclear fusion reactor without change and thus it is needed to development of the safety regulation concept which reflects the characteristics of nuclear fusion reactor. Safety regulation of nuclear fusion reactor employs deterministic approach until sufficient data are secured. However, regulation methodology of nuclear fusion reactor ...
2010-10-01
Chemical imaging of wood-polypropylene composites.
Recent investigations of wood plastic composites have revealed a detrimental effect of using lubricant systems in production. This includes nullifying part or all of the mechanical benefit of using a polar compatibilizer, maleic anhydride polypropylene (MAPP), in the composite formulation. This investigation utilizes lubricants labeled with deuterium in conjunction with Fourier transform infrared (FT-IR) spectroscopy to allow for the separation of individual lubricants from all other material constituents. All of the deuterium labeled lubricants, used without MAPP, revealed their expulsion from the wood interface during crystallization. MAPP coupling agent was found to exist near the wood, but it is unclear if any covalent bonding with the hydroxyl functionality on the wood surface occurred. The addition of zinc stearate lubricants appears to nullify the activity of the anhydride functionality near the wood surface as evidenced by a shift in ...
2006-08-01
Thermonuclear reactivity of D-T fusion plasma with spin-polarized fuel
Energy Technology Data Exchange (ETDEWEB)
The thermonuclear reactivity of deuterium(D) - tritium(T) fusion plasma with spin-polarized fuel has been studied. Two mechanisms of depolarization, collisions and waves, in the high temperature fusion plasma have been considered. The binary collisions have been found not to change the nuclear spin states. The waves with a frequency of a few GHz, however, changes the spin states appreciably, when {delta}B/B{sub 0} (the ratio of the amplitude of the fluctuating magnetic field to the external field) becomes larger than 10{sup -5}. (author)
1999-04-01
The production of carrier-free lead-203
International Nuclear Information System (INIS)
The chemical separation of carrier-free "2"0"3Pb following deuterium bombardment of a "2"0"3Tl target is described. Coprecipitation from strontium sulphate was used to separate the "2"0"3Pb from a solution of the thallium target in sulphuric acid. The SrSO_4 precipitate was filtered, washed and dissolved in hydrochloric acid, from which "2"0"3Pb was again separated by precipitation on sodium chloride from a strongly acid solution. Advantages of the system are discussed and optimum conditions given. (U.K.).
Rapid preparation of pyrogen-free 2H2(18)O for human-nutrition studies
International Nuclear Information System (INIS)
We describe a compact ultrafiltration system for the removal of pyrogens and bacteria from water labeled with the stable isotopes of deuterium and oxygen-18. The ultrafiltration system is constructed from readily available commercial components and can achieve complete removal of pyrogens and bacteria from 1L contaminated water within 30 min. By use of our procedure, loss of the isotopically labeled water by retention in the filtration system was minimal. The purified water is suitable for both oral and intravenous administration to healthy human subjects participating in nutrition studies.
Production of carrier-free lead-203
Energy Technology Data Exchange (ETDEWEB)
The chemical separation of carrier-free /sup 203/Pb following deuterium bombardment of a /sup 203/Tl target is described. Coprecipitation from strontium sulphate was used to separate the /sup 203/Pb from a solution of the thallium target in sulphuric acid. The SrSO/sub 4/ precipitate was filtered, washed and dissolved in hydrochloric acid, from which /sup 203/Pb was again separated by precipitation on sodium chloride from a strongly acid solution. Advantages of the system are discussed and optimum conditions given.
1982-07-01
Precise Measurement of the Neutron Magnetic Form Factor G{sub M}{sup n} in the Few-GeV{sup 2} Region
The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q{sup 2}=1.0-4.8 GeV{sup 2} with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.
2009-05-15
Precise Measurement of the Neutron Magnetic Form Factor GMn in the Few-GeV2 Region
International Nuclear Information System (INIS)
The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q2=1.0-4.8 GeV2 with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.
2009-05-15
On some mechanisms of 27.2 MeV #alpha#-particle interaction with carbon nuclei
International Nuclear Information System (INIS)
Using U-120 cyclotron in the course of correlation experiment one studied mechanisms of excitation and decay of "1"2C nucleus states resulting from irradiation of deuterium-polyethylene target by 27.2 MeV energy #alpha#-particle beam via recording of #alpha#-#alpha#-coincidence simultaneously with investigations of #alpha# + d-interactions. Production of "1"2C excited states decaying with the escape of #alpha#-particle and "8Be nucleus in the ground and the excited states is the basic mechanism of the studied #alpha# + "1"2C interaction
2001-05-01
Near-threshold production of {omega}-mesons in the pn{yields}d{omega} reaction
Energy Technology Data Exchange (ETDEWEB)
The first measurement of the pn{yields}d{omega} total cross-section has been achieved at mean excess energies Q{approx}28 and 57 MeV by using a deuterium cluster-jet target. The momentum of the fast deuteron was measured in the ANKE spectrometer at COSY-Juelich and that of the slow ''spectator'' proton (p{sub sp}) from the pd{yields}p{sub sp}d{omega} reaction in a silicon telescope placed close to the target. The cross-sections lie above those measured for pp{yields}pp{omega} but seem to be below theoretical predictions. (orig.)
2004-09-01
NPD Canada's first nuclear power station
Energy Technology Data Exchange (ETDEWEB)
This talk reviews the history of the Canadian nuclear-electric program highlighting Canada's first nuclear power station, the Nuclear Power Demonstration or NPD. NPD was commissioned and delivered electricity to Canadian consumers for the first time on june 4, 1962. The Canadian nuclear-electric program is based on the CANDU-PHW (Canadian Deuterium Uranium - Pressurized Heavy Water) concept which was conceived between 1955 and 1958 at the Chalk River Nuclear Laboratory (CRNL) of AECL, located a few miles from Deep River. This talk covers the history of the Canadian nuclear-electric activities dating back to 1939.
2002-07-01
Vibrational dynamics of hydrogen and deuterium in crystalline Pd_9Si_2
International Nuclear Information System (INIS)
Crystalline Pd_9Si_2 possesses an orthorhombic structure (Pnma) that is characterized by augmented triangular prismatic coordination of the silicon atoms such as that which occurs in several metal-rich transition-metal silicides. Recent neutron diffraction results for deuterium solution in this crystalline phase have indicated that deuterium occupies only one type of interstice, i.e., a Pd-defined pyramidal site in a four-fold position situated on a quadrilateral face of an empty triangular prism. The vibrational dynamics of both H and D located at this site were investigated by neutron vibrational spectroscopy. The low-temperature density of states (DOS) of H in Pd_9Si_2H_0_._2_5 indicates three well-defined optic vibrations located at 49.4, 67.2 and 75.5 meV. The lowest-energy feature is assigned to the normal-mode vibration perpendicular to the pyramidal base and the two higher-energy features are assigned to the two orthogonal normal-mode ...
1996-08-25
The effects of energy non-monochromaticity of "1"1B ion beams on "1"1B diffusion
International Nuclear Information System (INIS)
We have shown that energy contamination introduced by ion beam deceleration technology that is used to increase the beam currents available for low energy boron implants, can affect fabricated junctions adversely. A 4 keV "1"1B beam is extracted and retarded by a potential of -3.5 keV for 0.5 keV "1"1B implantation, or by a potential of -3.8 keV for 0.2 keV "1"1B implantation. Intentional beam contamination was introduced by turning off the retarding potential to allow the 4 keV "1"1B ions to irradiate Si wafers directly. The percentage of contamination, at levels of 0.1%, 0.2% and 0.3% was introduced. Rapid thermal annealing of all the implanted samples was performed under N_2 ambient at 1050 deg. C for 1 s. The dopant tail profiles themselves are not significant if the contamination levels are low. However, the much higher damage level coming from high energy ...
2005-08-01
International Nuclear Information System (INIS)
The absolute cross sections of "2"3Na(p,n)"2"3Mg, "2"7Al(p,n)"2"7Si and "3"0Si(#alpha#,n)"3"3S reactions were measured in the incident energy range of 5.05 to 5.80, 5.80 to 6.25 and 3.975 to 6.235 MeV respectively using a spherically shaped 4#pi# neutron detector. In the energy range 5.80 to 7.80 and 6.235 to 11.30 MeV the absolute cross sections of "2"3Na(p,n)"2"3Mg and "3"0Si-(#alpha#,n)"3"3S reactions were determined by optical model calculations. The cross sections of the inverse reactions "2"3Mg(n,p)"2"3Na and "3"3S(n,#alpha#)"3"0Si were also calculated by the same method for the neutron energy range of 10 keV to 7.50 MeV for each reaction. The cross section of the latter reaction in the neutron energy range of 10 keV to 840 keV was also determined from its inverse reaction "3"0Si(#alpha#,n)"3"3S by the application of the detailed balance theorem. The reactions for which the cross sections were determined are of ...
DECAY OF Ta$sup 177$ AND Lu$sup 177$ TO LEVELS IN Hf$sup 17$$sup 7$
The decays of Ta/sup 177/ and Lu/sup 177/ to levels in vestigated with beta spectrometers, NaI(Tl) gamma spectrometers, and fast coincidence and angular correlation techniques. Energy levels in Hf/sup 177/ were characterized according to their energy (kev), the Nilsson asymptotic quantum numbers (Nn/sub 2/ LAMBDA ), the total angular momentum and its component along the symmetry axis (I,K), and the parity ( pi ) as follows: 0STA5I4 7/2, 7/2-!; 112.97STA514 9/2, 7/ 2-!; 249.7STA5I4 11/2, 7/1-!; 32l.34STA624 9/2, 9/2+1; 447.9STA624 11/2, 585.8STA642 7/2, 3/2+1; 509.0STA5I2 5/2, 5/1-1; 605.5STA512 7/2, 5/2-!; 746.04STA633 7/2, 7/2+1; 848.2STA 633 9/2, 7/2+1; and 1058.38STA503 7/2, 7/2-!. The levels at 447.9, 488.8, and 585.8 kev are tentative. The spins and parities were uniquely determined by angular correlation and internal conversion data for the levels at 746.0 and 848.2 kev, asof the levels at 0, ...
1961-10-15
International Nuclear Information System (INIS)
Rossi X-ray Timing Explorer (RXTE) observations of the bright supernova remnant Cas A have revealed a hard power law component above 10 keV in addition to two thermal components inferred from ASCA measurements of the many line centroids from low-Z elements. The power law can be shown to be consistent with synchrotron emission from radio to hard x-rays by electrons of up to 4 x 10"1"3 eV. Measurement of the 1157 keV line by CGRO from "4"4Sc in the chain of decay of "4"4Ti predicts that the two "4"4Ti lines at 68 and 78 keV should appear at the CGRO intensity. RXTE has placed upper limits on such lines that are marginally consistent with the CGRO measurement. Implications of these results on sites for cosmic ray acceleration and nucleosynthesis are discussed.
1999-01-01
International Nuclear Information System (INIS)
The half-value thicknesses, linear and mass attenuation coefficients of biological samples such as bone, muscle, fat and water have been measured at 140, 364 and 662keV ?-ray energies by using the ATOMLABTM-930 medical spectrometer. The ?-rays were obtained from 99mTc, 131I and 137Cs ?-ray point sources. Also theoretical calculations have been performed in order to obtain the half-value thicknesses and, mass and linear attenuation coefficients at photon energies 0.001keV-20MeV for bone, muscle and water samples. The calculated value and the experimental results of this work and the other results in literature are found to be in good agreement.
2006-11-01
Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr
Energy Technology Data Exchange (ETDEWEB)
Neutron capture ..gamma..-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.
1985-01-15
Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr
International Nuclear Information System (INIS)
Neutron capture #gamma#-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.
1984-09-10
Traditional Fusion reaction: D + T n (14.07 MeV) + 4He (3.52 MeV ...
as for direct energy conversion in specialized direct electrical energy conversion plants. Figure 1. An energetic (~163KeV) proton and a 11boron nucleus fuse ...
International Nuclear Information System (INIS)
The decay of "1"0"1Mo to levels in "1"0"1Tc has been studied using the three-parameter (#gamma#-#gamma#-t) coincidence system of HpGe-HpGe detectors. According to the coincidence data, the decay scheme was modified. The positions of 221.80, 318.00, 377.90, 452.50, 515.42, 1011.05 and 1759.72 keV transitions have been arranged again, the transition positions of 104.70, 105.95 and 774.15 keV gamma-rays have been assigned for the first time, the positions of 169.00, 590.91, 980.52 and 1431.68 keV transitions have been reconfirmed, the 1508.01 keV gamma-ray was observed simultaneously for the first time and its transition position has been assigned. The #beta#-intensities and the values of log ft of most levels were calculated. (author)
2000-09-01
Studies on energy level schemes of some nuclei by Gamma-ray spectroscopy
International Nuclear Information System (INIS)
several authors tried to drive codes to construct nuclear level scheme of nuclei using a set of measured gamma -ray transitions and known energy levels, Ritz combination principle proved to be useful in constructing a more complete decay scheme. In this thesis the energy level schemes of some nuclei have been investigated by the measurements of the gamma - ray energies and use of Ritz combination code. The nuclei under investigation are "110m Ag (253 d)"110 Cd and "166m Ho (1200 yr) "166 E r. On the basis of the suggested level at 2249.02 keV by the Ritz code new positions of the two gamma-ray transitions at 677.5 and 706.6 KeV are found in decay scheme of "110m Ag. Also by this code, new position for the 994.84 KeV gamma-ray transition were established to depopulate the level at 1075.2 KeV.
1984-01-01
Mechanism for the reduction of interstitial supersaturations in MeV-implanted silicon
Energy Technology Data Exchange (ETDEWEB)
We demonstrate that the excess vacancies induced by a 1 MeV Si implant reduce the excess interstitials generated by a 40 keV Si implant during thermal annealing when these two implants are superimposed in silicon. It is shown that this previously observed reduction is dominated by vacancy annihilation and not by gettering to deeper interstitial-type extended defects. Interstitial supersaturations were measured using B doping superlattices (DSL) grown on a silicon-on-insulator (SOI) substrate. Implanting MeV and keV Si ions into the B DSL/SOI structure eliminated the B transient enhanced diffusion normally associated with the keV implant. The buried SiO{sub 2} layer in the SOI substrate isolates the deep interstitials-type extended defects of the MeV implant, thereby eliminating the possibility that these defects getter the interstitial excess induced by the keV Si implant. {copyright} {ital 1999 ...
1999-03-01
Mechanism for the reduction of interstitial supersaturations in MeV-implanted silicon
International Nuclear Information System (INIS)
We demonstrate that the excess vacancies induced by a 1 MeV Si implant reduce the excess interstitials generated by a 40 keV Si implant during thermal annealing when these two implants are superimposed in silicon. It is shown that this previously observed reduction is dominated by vacancy annihilation and not by gettering to deeper interstitial-type extended defects. Interstitial supersaturations were measured using B doping superlattices (DSL) grown on a silicon-on-insulator (SOI) substrate. Implanting MeV and keV Si ions into the B DSL/SOI structure eliminated the B transient enhanced diffusion normally associated with the keV implant. The buried SiO_2 layer in the SOI substrate isolates the deep interstitials-type extended defects of the MeV implant, thereby eliminating the possibility that these defects getter the interstitial excess induced by the keV Si implant. copyright 1999 American Institute ...
1999-03-01
Measurement of the 183 keV Resonance in 17O(p,alpha)14N using a Novel Technique
Energy Technology Data Exchange (ETDEWEB)
We have developed a novel technique for measurements of low energy (p,alpha) reactions using heavy ion beams and a differentially-pumped windowless gas target. We applied this new approach to study the 183 keV resonance in the 17O(p,alpha)14}N reaction. We report a resonance energy (center-of-mass) of 183.5{+0.1}{-0.4} keV, a resonance strength of 1.70 +/- 0.15 meV, and set an upper limit (95\\% confidence) on the total width of the state of < 0.1 keV. This resonance is important for the 17O(p,alpha)14}N reaction rate, and we find that 18F production is significantly decreased in low mass ONeMg novae but less affected in more energetic novae. We also report the first determination of the stopping power for oxygen ions in hydrogen gas near the peak of the Bragg curve (E=193 keV/u) to be (63+/-1)e-15 eV-cm2.
2007-06-01
Ion beam pulsing for time of flight (TOF) experiments
Energy Technology Data Exchange (ETDEWEB)
The essential mechanical and electronic parts of a beam pulsing system are described, which reaches an energy resolution of ..delta..E/E=0.1%-0.4% in the energy range from 100 eV and 10 keV.
1985-01-01
Experimental research on passive #gamma# scanning system at hot-cell for hull monitoring
International Nuclear Information System (INIS)
A simulated hull monitoring system based on passive #gamma# ray scanning was set-up in K-01 hot-cell, which consists of a simulated hull basket, a collimator system, a 150 cm"3 HPGe detector and an ORTEC-919 multichannel buffer-computer system. Six different kinds of experimental set-up were established to simulate the variations of #gamma# ray source term distribution (partly concentration) and the variations of matrix density (+46.1%). The experimental results show that the biases of peak area is better than -25.3% for "1"3"7Cs 662 keV #gamma# rays and -18.6% for "1"4"4Ce-"1"4"4Pr 2186 keV #gamma# rays. The hardness of pulse height spectrum is demonstrated to show that the peak area ratio of 2186 keV to 662 keV varies from 380 to 72 when the thickness of lead filter varies form 5 mm to 30 mm. Also studied are the design parameters of collimator system.
Electron Flux - 8.0 keV - ISWA wiki - ISWA - NASA
Nov 14, 2009 ... Ring Current electrons from the Fok Ring Current Model are computed using plasma and magnetic field values from the SWMF magnetosphere ...
Electron Flux - 4.7 keV - ISWA wiki - NASA
Nov 14, 2009 ... Ring Current electrons from the Fok Ring Current Model are computed using plasma and magnetic field values from the SWMF magnetosphere ...
Electron Flux - 179 keV - ISWA wiki - ISWA - NASA
Nov 14, 2009 ... Ring Current electrons from the Fok Ring Current Model are computed using plasma and magnetic field values from the SWMF magnetosphere ...
Annealing behavior of radiation damages in metal-silicides
International Nuclear Information System (INIS)
The annealing behavior of the radiation damage in epitaxial Pd_2Si and NiSi_2 films on Si, due to the implantation of 100 keV Ar ions, is investigated by using the channeling technique with "4He ions. (U.K.).
Parity nonconservation in "2"0"7Pb
International Nuclear Information System (INIS)
Two experiments are currently underway to measure the single-particle weak mixing matrix element for the 1064 KeV transition in "2"0"7Pb. One experiment measures the circular polarization of the 1064 KeV gamma ray emitted from an unpolarized source, while the other experiment measures the forward-backward asymmetry of gamma rays emitted from a polarized source. Analysis of the first set of polarized source data yields an upper limit of 46 eV for the single-particle weak mixing matrix element. copyright 1995 American Institute of Physics.
International Nuclear Information System (INIS)
Total M X-ray cross sections for 12 elements in atomic range 70#<=#Z#<=#92 were measured at 5.96 keV Mn K X-ray photon energy. The average M shell fluorescence yields (anti #omega#_M) of these elements have also been observed using the presently measured cross section values and the theoretical M shell photoionisation cross section values. (orig.).
Investigation of the "1"0"1Mo level and gamma-decay scheme by thermal neutron capture in "1"0"0Mo
International Nuclear Information System (INIS)
The #gamma#-radiation following thermal neutron capture in "1"0"0Mo has been studied by singles and coincidence measurements. A "1"0"1Mo level scheme has been deduced and is compared with the results of previous (d,p), (n,#gamma#) and "1"0"1Nb decay studies. The existence of the first excited state at 13.51 keV has been confirmed. The present data yield a neutron binding energy of 5398.4 KeV. (Auth.).
1975-03-01
Inelastic scattering of electrons by close-lying levels of isomeric nuclei
Energy Technology Data Exchange (ETDEWEB)
The process of inelastic scattering of hot plasma electrons with energies upto 3 keV by a pair of close-lying nuclear levels (..delta../ital E/less than or equal to2keV), one of whichis isomeric, is discussed. The transition cross sections in the nuclei/sup 242/Am, /sup 171/Lu, and /sup 73/Se are calculated. Estimates of the numberof isomeric nuclei de-excited as a result of electron-stimulated processes in aplasma with parameters characteristic of present-day experiments in controlledthermonuclear fusion are given.
1988-11-01
Energy Technology Data Exchange (ETDEWEB)
Neutral atom beams with energies above 200 keV may be required for various purposes in magnetic fusion devices following TFTR, JET and MFTF-B. These beams can be produced much more efficiently by electron detachment from negative ion beams than by electron capture by positive ions. We have investigated the efficiency with which such neutral atoms can be produced by electron detachment in partially ionized hydrogen plasma neutralizers.
1980-09-01
Energy Technology Data Exchange (ETDEWEB)
In this work, the chemical transformations induced by 5 keV protons (10{sup 6} ion cm{sup -2}) at the surface of 0.4 {mu}m polyacrylonitrile and polymethacrylonitrile films are analysed by XPS and IRRAS. Spectroscopic changes in both the polymers are globally similar, the most significant feature being a lower relative concentration of nitrogen with respect to carbon closer to the surface. Quantitatively, this change is more marked in the case of polyacrylonitrile which suggests a direct relation with the hydrogen in {alpha} to the nitrile function.
1999-05-02
International Nuclear Information System (INIS)
Decaborane (B_1_0H_1_4) cluster ions were implanted into n-Si(100) substrates to fabricate shallow p"+/n junctions. Implant energies of 2 keV, 5 keV, and 20 keV, equivalent to implant energies of the monomer boron ion of 174 eV, 435 eV, and 1.74 keV, respectively, were used at dosages of 1 X 10"1"2 /cm"2 and 1 X 10"1"3 /cm"2. The implanted samples were then subjected to activation annealing at 800 .deg. C, 900 .deg. C, and 1000 .deg. C for 10 s. By using secondary ion mass spectrometry (SIMS) depth profiles, we determined that the depth of the shallow junction (D_s) at a dosage of 1 X 10"1"3 /cm"2 was in the range 12 nm - 45 nm after annealing at 1000 .deg. C. D_s and transient enhanced diffusion (TED) were greatly reduced at implant energies lower than 5 keV, but thermal diffusion (TD) smoothly decreased. In particular, TED was suppressed in the p"+/n junction implanted at 2 ...
2004-06-01
International Nuclear Information System (INIS)
In various situations, measurements in prompt gamma neutron activation analysis (PGNAA) are performed to determine the amount of an elemental impurity relative to that of a major constituent of the matrix. An example of this is the measurement of hydrogen concentration in a metallic matrix. In all such cases, a major contributor to the uncertainty in the measurement is the uncertainty in the ratio of the high-purity germanium (HPGe) detector full-energy peak efficiency for the gamma-ray lines of interest (i.e., impurity and matrix gammas). Usually, the ratio is derived from the relative peak efficiency curve, which is determined using isotopic standards that emit multiple gamma ray lines (e.g., "1"5"2Eu) in the energy range <3000 keV, or using prompt gamma radionuclides (e.g., "1"4N, "3"5Cl) in the energy range >3000 keV. In either case, the uncertainty in the ratio of the peak efficiency values derived from such measurements will be on ...
2001-06-17
International Nuclear Information System (INIS)
Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by Deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on Tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-3 and 4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)
2006-11-13
International Nuclear Information System (INIS)
Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)
2005-11-23
Stability of the hydrogen atom of classical electrodynamics
We study the stability of the circular orbits of the electromagnetic two-body problem of classical electrodynamics. We introduce the concept of resonant dissipation, i.e. a motion that radiates the center-of-mass energy while the interparticle distance performs bounded oscillations about a metastable orbit. The stability mechanism is established by the existence of a quartic resonant constant generated by the stiff eigenvalues of the linear stability problem. This constant bounds the particles together during the radiative recoil. The condition of resonant dissipation predicts angular momenta for the metastable orbits in reasonable agreement with the Bohr atom. The principal result is that the emission lines agree with the predictions of quantum electrodynamics (QED) with 1 percent average error even up to the $40^{th}$ line. Our angular momenta depend logarithmically on the mass of the heavy body, such that the deuterium and the muonium atoms have essentially the ...
2004-01-01
Precise Determination of the Neutron Magnetic Form Factor to Higher Q{sup 2}
Energy Technology Data Exchange (ETDEWEB)
The neutron elastic magnetic form factor G{sub M}{sup n} has been extracted from quasielastic scattering from deuterium in the CEBAF Large Acceptance Spectrometer, CLAS [B. Mecking et al., Nucl. Inst. and Meth. A 503 (2003) 513]. The kinematic coverage of the measurement is continuous over a broad range, extending from below 1 GeV{sup 2} to nearly 5 GeV{sup 2} in four-momentum transfer squared. High precision is achieved by employing a ratio technique in which most uncertainties cancel, and by a simultaneous in-situ calibration of the neutron detection efficiency, the largest correction to the data. Preliminary results are shown with statistical errors only.
2005-06-13
Precise Determination of the Neutron Magnetic Form Factor to Higher Q"2
International Nuclear Information System (INIS)
The neutron elastic magnetic form factor G_M"n has been extracted from quasielastic scattering from deuterium in the CEBAF Large Acceptance Spectrometer, CLAS [B. Mecking et al., Nucl. Inst. and Meth. A 503 (2003) 513]. The kinematic coverage of the measurement is continuous over a broad range, extending from below 1 GeV"2 to nearly 5 GeV"2 in four-momentum transfer squared. High precision is achieved by employing a ratio technique in which most uncertainties cancel, and by a simultaneous in-situ calibration of the neutron detection efficiency, the largest correction to the data. Preliminary results are shown with statistical errors only.
2005-06-13
PROSPECTS AND STATUS OF LOW-ASPECT-RATIO TOKAMAKS
Energy Technology Data Exchange (ETDEWEB)
The prospects for the low-aspect-ratio (A) tokamak to fulfill the requirements of viable fusion power plants are considered relative to the present status in data and modeling. Desirable physics and design features for an attractive Blanket Test Facility and power reactors are estimated for low-A tokamaks based on calculations improved with the latest data from small pioneering experiments. While these experiments have confirmed some of the recent predictions for low-A, they also identify the remaining issues that require verification before reliable projections can be made for these deuterium-tritium applications. The results show that the low-A regime of small size, modest field, and high current offers a path complementary to the standard and high A tokamaks in developing the full potential of fusion power.
1995-01-01
Optimal detector deployment for the CANDU-600 pressurized heavy water reactor
An optimal deployment pattern of flux mapping detectors for a Canada uranium-deuterium (CANDU)-600 pressurized heavy water reactor (PHWR) is determined by obtaining an optimal feedback relationship between flux measurements and zone controllers. The reactor core is modeled with a time-dependent two-group, two-dimensional diffusion equation, and flux perturbation are expressed by model expansions. The modal expansion coefficients are used as elements of the state vector representing the system dynamics. An optimal feedback matrix connecting the flux measurement vector to the control vector is derived by minimizing a quadratic performance index involving both the state and control vectors. We obtain the detector effectiveness in terms of the optimal feedback matrix and determine optimal detector locations for the Wolsung Unit 1 reactor in Korea. We have tested the methodology through evaluation of flux maps generated through the CANDU flux mapping system.
1992-01-01
Internal friction of amorphous Pd/sub 80/ Si/sub 20/ metal doped with hydrogen isotopes
Energy Technology Data Exchange (ETDEWEB)
Internal friction of amorphous Pd/sub 80/Si/sub 20/ metal doped with hydrogen or deuterium was measured with a specially designed apparatus using amorphous metal sheet as a part of the electric oscillating circuit. Two peaks in Q/sup -1/ curve are observed. Applying the peak shift method to the first Snoek-like peak, we can determine the relaxation time from which the microdiffusion coefficient can be calculated. The obtained microdiffusion coefficient is about 10/sup -14/ m/sup 2//s at 200 K, being comparable with the macrodiffusion coefficient obtained from the releasing method. It can, however, not elucidate the hydrogen isotopic effect on the peak temperature of Q/sup -1/ curve, the activation energy for relaxation and the relaxation time from the present work because of the broadness of obtained Q/sup -1/ curve.
1983-02-01
HYFIRE: a tokamak- high-temperature electrolysis system
Energy Technology Data Exchange (ETDEWEB)
Brookhaven National Laboratory is involved in a conceptual design study of a commercial nuclear power system which utilizes high-temperature electrolysis to produce synthetic fuels. The system is called HYFIRE. It includes a tokamak fusion power reactor supplying electrical and thermal energy to an array of electrolytes. The electrolytes produce hydrogen which can be used either directly as a fuel or in the production of hydrocarbons. The purpose of the study is to provide a mechanism for DOE to further assess the commercial potential of fusion using a tokamak reactor to produce synthetic fuel. The HYFIRE design is based on the tokamak commercial power reactor, STARFIRE. STARFIRE uses the deuterium/tritium/lithium fuel cycle. The HYFIRE study assumes the plasma shape and characteristics of STARFIRE study but uses a different blanket design. This study is particularly interested in the possibility of using the STARFIRE tokamak in the production of synthetic fuels.
1980-01-01
Cumulative production of direct photons and leptonic pairs
International Nuclear Information System (INIS)
Leptonic pair production on nuclei ad EMC-effect are discussed within the frames of the flucton model with scaling distortion. Cumulative production of direct photons and leptonic pairs as a test of the model of hard collisions is considered. The results of calculations of massive leptonic pair production cross sections on nucleus fluctons, caculations of the ratio of deuterium and iron structural functions, cross sections of direct photon production on sup(181)Ta nuclei at Esub(p)=400 GeV and cross section of #pi#-meson production in the model of hard collisions are presented. Experimental discovery of direct cumulative photons is concluded to be important for understanding the mechanism of parton hard scattering from nucleus fluctons.
1984-06-19
Beam emittance measurements of ORNL negative ion sources
Energy Technology Data Exchange (ETDEWEB)
The emittances of hydrogen and deuterium negative ion beams produced by volume ion sources have been measured in a transverse plane normal to the beam trajectory. The extraction voltage was varied from 10 to 40 kV, and the transverse magnetic field in the Penning discharges was varied from 0.1 to 0.2 T. Measurements were made on beams with current densities up to 60 mA/cm/sup 2/ at Oak Ridge National Laboratory with an emittance scanner originally developed at Los Alamos National Laboratory. The beam profile at the scanner can be used to improve the accuracy of the emittance measurements. Other factors affecting emittance measurements are discussed. This analysis may be applicable to other ion sources. 6 figs.
1989-01-01
Energy Technology Data Exchange (ETDEWEB)
Pulse reactor experiments were conducted on the reactions of unlabeled or deuterium- or oxygen-18-labeled allyl alcohols over molybdenum trioxide and various bismuth molybdates in the absence or presence of oxygen and ammonia. The allyl alcohol apparently adsorbed on oxidation sites to form acrolein via allyl molybdates, and on Broensted acid sites to form diallyl ether via an allyl carbonium ion. The bismuth enhanced ..cap alpha..-hydrogen abstraction, which was the rate-determining step in the oxidation. The product distributions provided evidence that the selective oxidation of propylene to acrolein proceeds via a m-allyl molybdate which collapses to an O o-allyl molybdate prior to the second hydrogen abstraction, and that the analogous N o-complex in ammoxidation undergoes two hydrogen abstractions to form acrylonitrile. Detailed reaction schemes are developed.
1980-05-01
Active hydrogen by chemical ionization mass spectrometry.
A means of determination of a ctive hydrogen of hydroxyl, carboxyl, sulfhydryl, amino, amido and sulfonamido groups by chemical ionization mass spectrometry using ammonia and trideuterioammonia as reagent gases is described. The method is based on exchange of active hydrogen for deuterium occurring during the chemical ionization process using trideuterioammonia, with comparison of m/z for ammonium adduct [M + NH1]+ and trideuterioammonium adduct [M--nH + nD + ND4]+, or of protonated molecular ion [M + H]+ and deuteronated molecular ion [M--nH + nD + D]+ yielding the number of active hydrogens. Applications have been made to several classes of biologically important compounds. PMID:427257
1979-01-01
Energy Technology Data Exchange (ETDEWEB)
Syntheses are described for tetra and pentadeutero indole-3-acetic acid (IAA) labeled in positions 4,5,6,7 or 2,4,5,6,7 of the indole moiety. Polydeuterated IAA is proposed as an internal standard for gas chromatographic-mass spectrometric analysis of IAA by selected ion monitoring. Nanogram amounts of IAA may be assayed by monitoring the base peak of IAA at m/z = 130 (134 for d/sub 4/-IAA) and the molecular ion of the methyl ester of IAA at 189 (193 for d/sub 4/-IAA). Deuterium in positions 4,5,6, and 7 and, to only a slightly lesser extent, that in position 2 of IAA is retained during alkali treatment, thus permitting use of these compounds as internal standards for assay of IAA released by alkaline hydrolysis of ester and amide conjugates. The use of polydeutero internal standards separates the standards from the isotope cluster caused by the normal abundance of heavy isotopes and also permits use of reduced mass resolution, thus leading to a 10-fold increase in ...
1980-10-01
Role of Fusion Energy in a Sustainable Global Energy Strategy
Energy Technology Data Exchange (ETDEWEB)
Fusion energy is one of only a few truly long-term energy options. Since its inception in the 1950s, the vision of the fusion energy research program has been to develop a viable means of harnessing the virtually unlimited energy stored in the nuclei of light atoms--the primary fuel deuterium is present as one part in 6,500 of all hydrogen. This vision grew out of the recognition that the immense power radiated by the sun is fueled by nuclear fusion in its hot core. Such high temperatures are a prerequisite for driving significant fusion reactions. The fascinating fourth state of matter at high temperatures is known as plasma. It is only in this fourth state of matter that the nuclei of two light atoms can fuse, releasing the excess energy that was needed to separately bind each of the original two nuclei. Because the nuclei of atoms carry a net positive electric charge, they repel each other. Hydrogenic nuclei, such as deuterium and tritium, ...
2001-03-07
Electrodeless, multi-megawatt reactor for room-temperature, lithium-6/deuterium nuclear reactions
International Nuclear Information System (INIS)
This paper describes a reactor design to facilitate a room-temperature nuclear fusion/fission reaction to generate heat without generating unwanted neutrons, gamma rays, tritium, or other radioactive products. The room-temperature fusion/fission reaction involves the sequential triggering of billions of single-molecule, "6LiD 'fusion energy pellets' distributed in lattices of a palladium ion accumulator that also acts as a catalyst to produce the molecules of "6LiD from a solution comprising D_2O, "6LiOD with D_2 gas bubbling through it. The D_2 gas is the source of the negative deuterium ions in the "6LiD molecules. The next step is to trigger a first nuclear fusion/fission reaction of some of the "6LiD molecules, according to the well-known nuclear reaction: "6Li + D #-># 2"4He + 22.4 MeV. The highly energetic alpha particles ("4He nuclei) generated by this nuclear reaction within the palladium will cause shock and vibrations in the palladium lattices, leading ...
Energy Technology Data Exchange (ETDEWEB)
4-(Methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK), a carcinogenic tobacco specific nitrosamine, can be converted to electrophilic diazohydroxide intermediates by metabolic hydroxylation of either the methylene carbon (carbon 4) or the methyl carbon attached to the nitrosamine group. To investigate the relative importance of these two processes in NNK mutagenesis, we synthesized 4,4-dideutero-4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone((4,4,-D2)NNK) and 4-(trideuteromethylnitrosamino)-1-(3-pyridyl)-1-butanone ((CD3) NNK), and evaluated their mutagenic activities in Salmonella typhimurium tester strains. In the presence of Aroclor induced rat liver 9000 g supernatant, NNK and (4,4-D2)NNK had comparable mutagenic activities towards S. typhimurium TA 1535 and TA 100, but (CD3)NNK was inactive in both strains. These results suggest that hydroxylation of the methyl group of NNK is more important than hydroxylation of carbon 4 in its activation to a mutagen. To test the inherent ...
1983-01-01
International Nuclear Information System (INIS)
Nuclear Reaction Analysis (NRA) with deuteron ion beams has been used to probe for ion implanted nitrogen and carbon with high sensitivity in zinc oxide and silicon single crystals. The ion implanted N was measured using 1.4 MeV deuteron ion beams and was found to be in agreement with calculated values. The limit of detection for N in ZnO is 8x1014 ions cm-2. Raman measurements of the ion implanted samples showed three additional modes at 275, 504, and 644 cm-1 compared to the un-implanted ZnO crystals. The NRA and Raman results provided information on the N concentration, depth distribution, and structural changes that occur in dependence on the nitrogen ion fluences. The deuterium induced 12C(d,p)13C reaction was used to measure the carbon impurity/dose in ion implanted silicon. It was found that the use of a large cold shield (liquid nitrogen trap) in the ion implanter chamber greatly reduces the amount of carbon impurity on the surface of ion implanted silicon. ...
2008-11-03
An overview of AECL's participation in the Korean Wolsung Tritium Removal Facility Project (WTRF)
International Nuclear Information System (INIS)
Full text: In heavy-water-moderated power reactors, tritium is primarily produced by neutron capture in deuterium nuclei in the moderator and coolant. For CANDU 6 reactors, the estimated steady-state values are #approx# 3 TBq#centre dot#kg"-"1 D_2O in the moderator and #approx# 74 GBq#centre dot#kg"-"1 D_2O in the coolant. Tritium removal is one option available to reactor operators for use in their heavy water and tritium management strategies. The WTRF is designed to remove tritium from tritiated heavy water in each of the four CANDU units at the Wolsung Site, to immobilize the tritium and to store it on site. The detritiation process is based on three steps: the first one (front-end) involves the transfer of tritium from heavy water to deuterium gas; the second one (enrichment) concentrates the tritium in a cryogenic distillation system to produce essentially pure D_2 and T_2 streams; and in the third step the tritium is packaged for ...
2007-11-07
Variability and spectral modeling of the hard X-ray emission of GX 339-4 in a bright low/hard state
We study the high-energy emission of the Galactic black hole candidate GX 339-4 using INTEGRAL/SPI and simultaneous RXTE/PCA data. By the end of January 2007, when it reached its peak luminosity in hard X-rays, the source was in a bright hard state. The SPI data from this period show a good signal to noise ratio, allowing a detailed study of the spectral energy distribution up to several hundred keV. As a main result, we report on the detection of a variable hard spectral feature (>150 keV) which represents a significant excess with respect to the cutoff power law shape of the spectrum. The SPI data suggest that the intensity of this feature is positively correlated with the 25 - 50 keV luminosity of the source and the associated variability time scale is shorter than 7 hours. The simultaneous PCA data, however, show no significant change in the spectral shape, indicating that the source is not undergoing a canonical ...
2010-01-01
International Nuclear Information System (INIS)
We have investigated the characteristics of ion-beam-induced spontaneous etching (IBISE) of GaAs in Cl_2 ambient by using a Ga-focused ion beam (FIB) with an energy ranging from 3 to 15 keV. The etched depth of the irradiated region was more than 20 times greater than that of unirradiated region. When the sputtered depth by FIB irradiation amounted to around 8 A at each ion energy, the etched depth in Cl_2 ambient for 1 hour became saturated. The saturated etched depths were 450, 550, 750 and 800 A at the ion energy of 3, 5, 10 and 15 keV, respectively. The residual damage of the etched surface was also investigated by photoluminescence (PL) measurement. The maximal PL intensity was obtained at around the threshold dose of IBISE and increased with decreasing ion energy. The full recovery of PL intensity was observed at the ion energy of 3 keV after annealing at 400degC. (author).
Energy Technology Data Exchange (ETDEWEB)
The reduction of transient enhanced diffusion (TED) with reduced implantation energy has been investigated and quantified. A fixed dose of 1{times}10{sup 14} cm{sup {minus}2} Si{sup +} was implanted at energies ranging from 0.5 to 20 keV into boron doping superlattices and enhanced diffusion of the buried boron marker layers was measured for anneals at 810, 950, and 1050{degree}C. A linearly decreasing dependence of diffusivity enhancement on decreasing Si{sup +} ion range is observed at all temperatures, extrapolating to {approximately}1 for 0 keV. This is consistent with our expectation that at zero implantation energy there would be no excess interstitials from the implantation and hence no TED. Monte Carlo modeling and continuum simulations are used to fit the experimental data. The results are consistent with a surface recombination length for interstitials of {lt}10 nm. The data presented here demonstrate that in the range of annealing ...
1997-11-01
International Nuclear Information System (INIS)
The reduction of transient enhanced diffusion (TED) with reduced implantation energy has been investigated and quantified. A fixed dose of 1x10"1"4 cm"-"2 Si"+ was implanted at energies ranging from 0.5 to 20 keV into boron doping superlattices and enhanced diffusion of the buried boron marker layers was measured for anneals at 810, 950, and 1050 degree C. A linearly decreasing dependence of diffusivity enhancement on decreasing Si"+ ion range is observed at all temperatures, extrapolating to #approx#1 for 0 keV. This is consistent with our expectation that at zero implantation energy there would be no excess interstitials from the implantation and hence no TED. Monte Carlo modeling and continuum simulations are used to fit the experimental data. The results are consistent with a surface recombination length for interstitials of <10 nm. The data presented here demonstrate that in the range of annealing temperatures of interest for p-n ...
Nanoporous structure formations on germanium surfaces by focused ion beam irradiations
International Nuclear Information System (INIS)
The formation of porous structures of nanometre size (nanoporous structures) on germanium (Ge) surfaces by focused ion beam (FIB) irradiations was investigated using various FIB conditions such as ion species, irradiation energies, total fluences, fluence rates, and incident angles. FIB-irradiated regions were observed using a scanning electron microscope and an atomic force microscope. It is found that, using a focused Ga ion beam (Ga FIB) at an energy of 100 keV, the irradiated Ge surface swelled up to ion fluence of 2 x 10"1"7 cm"-"2 with nanoporous structures and then was etched for larger fluences. The shape of swollen nanoporous structures depended on the fluence rate and the incident angle of the Ga FIB. However, such porous structures were observed neither for low-energy (15-30 keV) FIB irradiations using Si and Au ions nor for high-energy (200 keV), heavy ion (Au) irradiation. These observations might be helpful in ...
2007-11-07
Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization
Energy Technology Data Exchange (ETDEWEB)
The measurements of the K X-ray intensity ratio I(K{alpha} {sub 2}/K{alpha} {sub 1}), I(K{beta} {sub 1}/K{alpha} {sub 1}) and I(K{beta}/K{alpha}) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a {sup 241}Am and 123.6 keV {gamma}-rays from a {sup 60}Co were used, and following the radioactive decay of {sup 51}Cr, {sup 55}Fe, {sup 67}Ga, {sup 99}Tc, {sup 111}In, {sup 131}I, {sup 133}Ba, {sup 133}Xe, {sup 137}Cs, {sup 201}Tl and {sup 226}Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.
2007-01-15
Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization
International Nuclear Information System (INIS)
The measurements of the K X-ray intensity ratio I(K#alpha# _2/K#alpha# _1), I(K#beta# _1/K#alpha# _1) and I(K#beta#/K#alpha#) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV #gamma#-rays from a "2"4"1Am and 123.6 keV #gamma#-rays from a "6"0Co were used, and following the radioactive decay of "5"1Cr, "5"5Fe, "6"7Ga, "9"9Tc, "1"1"1In, "1"3"1I, "1"3"3Ba, "1"3"3Xe, "1"3"7Cs, "2"0"1Tl and "2"2"6Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.
2007-01-01
Focused ion beam processes for high-T/sub c/ superconductors
International Nuclear Information System (INIS)
Focused ion beam (FIB) processes have been developed for Y--Ba--Cu--O superconductor films. A Y--Cu liquid metal ion source has been fabricated, using a Y_6_7 --Cu_3_3 eutectic alloy as the ion source. As-sputtered Y--Ba--Cu--O film etch rate ratios to GaAs(100) and Si(100) substrates are 0.28 and 1.4 for 130-keV Au"+ FIB ion etching, respectively. Y--Ba--Cu--O submicron patterns have been demonstrated by using FIB lithography and Cl_2 reactive ion beam etching. Moreover, a Y--Ba--Cu--O superconducting line with 4-#mu#m linewidth has been fabricated by annealing an as-sputtered Y--Ba--Cu--O line pattern. T/sub c/ control of Y--Ba--Cu--O film has been achieved by 200-keV Ne"+, using conventional ion implantation and 300 keV Si"+"+ FIB ion implantation.
Energy Technology Data Exchange (ETDEWEB)
The peak flux relationship between hard X-rays and microwaves from solar flares is studied using about 400 events simultaneously recorded with the hard X-ray burst spectrometer on the SMM satellite and the Nobeyama 17 GHz radiometer. The data indicate that the hard X-ray and microwave peak fluxes correlate best for X-ray energies of less than about 80 keV for impulsive flares and greater than about 360 keV for extended flares. By postulating that electrons responsible for microwave emission at 17 GHz are those emitting hard X-rays at these photon energies, it is concluded that: (1) in impulsive flares, microwaves at about 20 GHz are emitted mainly by electrons of less than about 200 keV from a layer through which the electrons stream down into the thick-target hard X-ray source; and (2) in extended flares, microwaves are emitted mainly by MeV electrons trapped in a coronal loop or loops. 59 references.
1988-01-01
Comparison of beam-induced deposition using ion microprobe
International Nuclear Information System (INIS)
The localized Pt deposition on Si by 30 keV Ga"+ focused ion beam (FIB), 10 keV electron beam (EB) or dual beams (FIB and EB) using precursor gas has been compared by analysis using a 300 keV Be"2"+ microprobe with a beam spot size of 80 nm. The distribution of deposited Pt, Ga from the ion beam itself, and C from the precursor gas was obtained at and nearby the deposited areas by micro-RBS spectra and RBS mapping. All of the beam processed areas showed a uniform Pt distribution at the deposited areas. The amount of Pt atoms increased with the increase in ion or electron dose due to the decomposition of precursor gas. The thickness of Pt layer by EB is considerably less than that by FIB due to the reduced deposition rate. Ga atoms from the center of processed areas partly redeposited at and nearby the FIB processed areas within #approx#3 #mu#m. The Ga incorporation by dual beam processing was reduced compared with that by ...
1999-01-02
Accretion Properties of A Sample of Hard X-ray (<60keV) Selected Seyfert 1 Galaxies
We examine the accretion properties in a sample of 42 hard (3-60keV) X-ray selected nearby broad-line AGNs. The energy range in the sample is harder than that usually used in the similar previous studies. These AGNs are mainly complied from the RXTE All Sky Survey (XSS), and complemented by the released INTEGRAL AGN catalog. The black hole masses, bolometric luminosities of AGN, and Eddington ratios are derived from their optical spectra in terms of the broad H$\\beta$ emission line. The tight correlation between the hard X-ray (3-20keV) and bolometric/line luminosity is well identified in our sample. Also identified is a strong inverse Baldwin relationship of the H$\\beta$ emission line. In addition, all these hard X-ray AGNs are biased toward luminous objects with high Eddington ratio (mostly between 0.01 to 0.1) and low column density ($<10^{22} \\mathrm{cm^{-2}}$), which is most likely due to the selection effect of the surveys. The hard ...
2008-01-01
International Nuclear Information System (INIS)
Total M shell X-ray production cross section for 11 elements with 69 #<=# Z #<=# 92 have been measured using an incident photon energy of 5.96 keV. Measurements have been performed using an "5"5Fe annular source and a Si(Li) detector. Average M shell fluorescence yield at each incident photon energy has been deduced, using the experimental total M X-ray production cross section and theoretical M shell photoionization cross section. Present experimental results are compared with other experimental and theoretical values. Reasonable agreement (to within 0.3-28%) is typically obtained between present and other experimental and theoretical values.
2005-04-01
International Nuclear Information System (INIS)
The effect of swelling of crystalline Ge irradiated at room temperature with 30 keV Ga"+ focused ion beam (FIB) was studied by means of in situ FIB imaging, atomic force microscopy (AFM) and transmission electron microscopy (TEM). The swelling occurred in the surface region of amorphous damage layer which was formed during ion irradiation. The degree of swelling reaches values up to 10 times for an implantation dose of #approx#10"1"7 ions/cm"2. Cross-secitonal TEM examination showed that the swelling is due to formation of a porous layer with a honeycomb structure. (author). 8 refs., 4 figs.
2005-11-20
The Micro-X Imaging Spectrometer Instrument
The Micro-X instrument is a NASA funded, rocket borne X-ray imaging spectrometer planned for launch in January 2011. An array of Transition Edge Sensors (TESs) will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. This will be a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat sink, and will be read out by a SQUID time division multiplexer. X-rays will be focused onto the TES array of 128 pixels on a 600 micron pitch by a conically approximated Wolter optic with an effective area of 200 cm2. The spectrometer will have a field of view of 11.8 arcmin. We describe the design and development progress of the instrument.
2010-01-01
Study of point defect detectors in Si
International Nuclear Information System (INIS)
The importance of point defects in semiconductor and function materials has been studied in detail, but effective means for detecting point defects has not been available for a long time. The end of range defects in Si, produced by 140 keV Ge"+ implantation, were investigated as detectors for measuring the interstitial concentration created by 42 keV B"+ implantation. The concentration of interstitial resulting from the B"+ implantation and the behavior of the interstitial flux under different annealing condition were given. The enhanced diffusion in the boron doped EPI marker, resulting from mobile non-equilibrium interstitials was demonstrated to be transient. Interstitial fluxes arising from processing can be detected by transient enhanced diffusion (TED) of doped marker layers as well
1999-05-01
International Nuclear Information System (INIS)
The decay of "1"0"1Mo to levels in "1"0"1Tc has been studied using the three-parameter (#gamma#-#gamma#-t) coincidence system of HpGe-HpGe detectors. From the coincidence data, the new decay scheme was constructed. The previously reported 104.70, 105.95 and 774.15 keV #gamma# rays were observed, and have been assigned to the decay scheme for the first time. A newly observed 1508.01 keV #gamma# ray has also been assigned to the scheme for the first time. The intensities of #beta#"- and the values of log ft to most levels were calculated
2000-04-01
Structure of Heavy Fe Nuclei at the Point of Transition at N #approx# 37
International Nuclear Information System (INIS)
We have studied energy levels in "6"3Fe populated in the #beta#-decay of "6"3Mn. A new (preliminary) level scheme of "6"3Fe includes 10 excited states connected by 21 #gamma#-rays. The first excited states at 357 and 451 keV have the level half-lives of 110 ps and 780 ps, respectively. Three states, at 357, 451 and 1132 keV, are strongly #beta#-fed with log ft #approx# 5, while there is only a very week #beta#-feeding, if any at all, to the ground state. The new results imply that "6"3Fe departs from a simple shell model structure observed for heavier N = 37 isotones of "6"5Ni and "6"7Zn. (author)
2009-03-01
International Nuclear Information System (INIS)
The L-shell x-ray intensity ratios I(L_#beta#)/I(L_#alpha#) and I(L_#gamma#)/I(L_a_l_p_h_a) for elements with 73 #<=# Z #<=# 83 have been measured at photon incident energies of 17.8, 25.8 and 46.9 keV. The emitted x-rays were measured with a Si(Li) detector system. The results for Re, Pt and Tl are being reported for the first time. A comparison is made of the experimental results with the calculated values obtained by using the theoretical x-ray emission rates, subshell ionisation cross sections, subshell fluorescence yields and Coster-Kronig transition probabilities. The experimental results are in reasonable agreement with the theoretical values. (author).
1988-01-01
International Nuclear Information System (INIS)
Gamma ray spectra in the decay of 185Ta and 185mW have been studied with Ge (Li) detectors. The 185mW isomeric transition at 131.6 keV is shown to be of E3 multipolarity. A level scheme of 185W is proposed with the following energy levels (energies in keV, spin and K quantum numbers in brackets): 0 (3/2- 3/2), 23.5 (1/2- 1/2), 65.9 (5/2- 3/2), 93.5 (3/2- 1/2) (uncertain), 173.9 (7/2- 3/2), 188.1 (5/2- 1/2), 197.5 (11/2+ 11/2) , 243.5 (7/2- 7/2), and 390.8 (9/2- 7/2)
1996-03-04
Nuclear structure studies via neutron interactions
Energy Technology Data Exchange (ETDEWEB)
Research preformed consisted of: (1) publication of an experimental paper for the n + {sup 40}Ar high resolution total cross section and submission of a theoretical paper dealing with the prediction of the average parameters deduced from the the data; (2) preliminary R-matrix analysis of the neutron total cross section data for the n + {sup 208}Pb systems, up to an energy of 1.7 MeV; (3) completed the analysis of neutron total cross section of data for n + {sup 54}Fe up to energy of 500 keV, with j{sup {pi}} values confirmed, in most cases, by differential scattering data; (4) analysis of total cross section data for the n + {sup 88}Sr system up to an energy of 175 keV; (5) development of a graphical interface for the code RFUNC, used to calculate the differential scattering cross sections, for comparison with measurements.
1991-03-01
International Nuclear Information System (INIS)
The MCNPE-BO and MCNP4 Monte Carlo electron-photon codes were used to calculate the dose equivalent per unit fluence at various depths in tissue-equivalent slab phantoms for broad parallel beams of monoenergetic electrons with energies from 50 keV to 10 MeV. The study was carried out in the framework of the activities of a ICRP/ICRU Joint Task Group with the support of EURADOS WG4 (Numerical Dosimetry). Some preliminary results and comparisons as well as a general discussion on the performances of the codes are presented, demonstrating quite a satisfactory agreement among the results obtained using the two codes and those of other authors. (author).
International Nuclear Information System (INIS)
An ytterbium-169 high dose rate brachytherapy source, distinguished by an intensity-weighted average photon energy of 92.7 keV and a 32.015#+-#0.009 day half-life, is characterized in terms of the updated AAPM Task Group Report No. 43 specifications using the MCNP5 Monte Carlo computer code. In accordance with these specifications, the investigation included Monte Carlo simulations both in water and air with the in-air photon spectrum filtered to remove low-energy photons below 10 keV. TG-43 dosimetric data including S_K, D(r,#theta#), #LAMBDA#, g_L(r), F(r,#theta#), #phi#_a_n(r), and #phi#_a_n were calculated and statistical uncertainties in these parameters were derived and calculated in the appendix.
2006-01-01
Microprobe RBS analysis of localized processed areas by FIB etching and deposition
International Nuclear Information System (INIS)
Localized beam-processed areas using chemical reactions induced by a 30 keV Ga"+ focused ion beam (FIB) with and without I_2 (etching) and (CH_3)_3CH_3C_5H_5Pt gases (Pt deposition) have been analyzed using a 300 keV Be"2"+ microprobe with a beam spot size of 50-80 nm. The analyzed results have been compared with energy dispersive X-ray (EDX) analysis using an electron beam. The EDX analysis only indicated incorporated impurities at high fluence such as Ga, Pt and C, while microprobe RBS analysis could detect residual iodine with low concentration which couldn't be detected by EDS analysis because of the lower sensitivity of the EDX analysis for heavy atoms.
2001-07-01
Light emission from hydrogen-copper interaction at grazing incidence
Energy Technology Data Exchange (ETDEWEB)
The optical emission of excited H reflected from clean Cu(110) after impingement of H/sup +/ and H/sub 2//sup +/ in the energy range of 250 eV to 20 keV per nucleon at 70/sup 0/ angle of incidence to the surface normal was measured. For incident 10 keV H/sub 2//sup +/, the highest excited hydrogen state detected was the n=10 level. The Hsub(..cap alpha..) yield was found to be fluence and energy dependent. This effect is attributed either to fast sputtered hydrogen, surface roughness or to an increase with hydrogen concentration in electron states of p-like symmetry near the Fermi level of copper. The Hsub(..cap alpha..) yield per reflected nucleon shows approximately an exponential dependence on both projectile energy per nucleon and scattered particle reciprocal velocity perpendicular to the surface.
1984-03-01
Light emission from hydrogen-copper interaction at grazing incidence
International Nuclear Information System (INIS)
The optical emission of excited H reflected from clean Cu(110) after impingement of H"+ and H_2"+ in the energy range of 250 eV to 20 keV per nucleon at 70"0 angle of incidence to the surface normal was measured. For incident 10 keV H_2"+, the highest excited hydrogen state detected was the n=10 level. The Hsub(#alpha#) yield was found to be fluence and energy dependent. This effect is attributed either to fast sputtered hydrogen, surface roughness or to an increase with hydrogen concentration in electron states of p-like symmetry near the Fermi level of copper. The Hsub(#alpha#) yield per reflected nucleon shows approximately an exponential dependence on both projectile energy per nucleon and scattered particle reciprocal velocity perpendicular to the surface. (orig.).
1983-07-01
Focused Ion Beam Induced Effects on MOS Transistor Parameters
Energy Technology Data Exchange (ETDEWEB)
We report on recent studies of the effects of 50 keV focused ion beam (FIB) exposure on MOS transistors. We demonstrate that the changes in value of transistor parameters (such as threshold voltage, V{sub t}) are essentially the same for exposure to a Ga+ ion beam at 30 and 50 keV under the same exposure conditions. We characterize the effects of FIB exposure on test transistors fabricated in both 0.5 {micro}m and 0.225 {micro}m technologies from two different vendors. We report on the effectiveness of overlying metal layers in screening MOS transistors from FIB-induced damage and examine the importance of ion dose rate and the physical dimensions of the exposed area.
1999-07-28
Energy Technology Data Exchange (ETDEWEB)
The energy dispersive beamline X6A at the National Synchrotron Light Source employs a curved crystal monochromator (polychromator) which focuses a range ([similar to]1 keV) of x-ray energies into a narrow (100--120 [mu]m) line image. Although this beamline was constructed primarily for time-dependent EXAFS experiments, we have begun to explore the use of this instrument for energy dispersive diffraction experiments with different types of sample including macromolecular crystals. The tunability ([ital E]=6.5 to 21 keV) and flexibility ([Delta][ital E]=100--1000 eV) of the instrument makes the beamline ideal as a test bed for the application of polychromatic single-crystal diffraction techniques to different chemical or biological materials.
1995-02-01
Energy Technology Data Exchange (ETDEWEB)
The measurements of the K X-ray intensity ratio I(K{sub {beta}})/I(K{sub {alpha}}) for the 17 elements Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Br, Rb, Sr, Y, Zr, Nb and Mo have been done following ionization by 59.5keV {gamma}-rays from a {sup 241}Am point source. Ratios of emission probabilities of Auger electrons and the vacancy transfer coefficients have been extracted in terms of the intensity ratios. It is found that the present results agree well with earlier fitted values and the semi-empirical values.
2006-01-15
Characteristics of wave-particle interaction in a hydrogen plasma
International Nuclear Information System (INIS)
We study the characteristics of cyclotron wave-particle interaction in a typical hydrogen plasma. The numerical calculations of minimum resonant energy Emin, resonant wave frequency ?, and pitch angle diffusion coefficient D?? for interactions between R-mode/L-mode and electrons/protons are presented. It is found that Emin decreases with ? for R-mode/electron, L-mode/proton and L-mode/electron interactions, but increase with ? for R-mode/proton interaction. It is shown that both R-mode and L-mode waves can efficiently scatter energetic (10 keV-100 keV) electrons and protons and cause precipitation loss at L=4, indicating that perhaps wave-particle interaction is a serious candidate for the ring current decay. (authors)
2008-09-01
Atomic scale models of Ion implantation and dopant diffusion in silicon
Energy Technology Data Exchange (ETDEWEB)
We review our recent work on an atomistic approach to the development of predictive process simulation tools. First principles methods, molecular dynamics simulations, and experimental results are used to construct a database of defect and dopant energetics in Si. This is used as input for kinetic Monte Carlo simulations. C and B trapping of the Si self- interstitial is shown to help explain the enormous disparity in its measured diffusivity. Excellent agreement is found between experiments and simulations of transient enhanced diffusion following 20-80 keV B implants into Si, and with those of 50 keV Si implants into complex B-doped structures. Our simulations predict novel behavior of the time evolution of the electrically active B fraction during annealing.
1999-03-01
International Nuclear Information System (INIS)
L_#alpha#/L_l X-ray intensity ratios have been measured in elements Ta, W, Au, Hg, Tl, Pb, Bi, Th and U using L-shell photoionization by 60 keV photons. The present results are found to agree with the calculated values of Scofield within experimental uncertainties. (author).
1983-11-21
Search for anisotropy in the L x-gamma angular correlations following the decay of "2"0"7Bi
International Nuclear Information System (INIS)
An investigation of the Ll x-#gamma# angular correlations following the decay of "2"0"7Bi is done by using a Si(Li) semiconductor counter as L x-ray detector. Coincidence measurements at five different angles were made between the 570-keV #gamma# ray (gated in the movable counter) and the Ll x spectrum (displayed in a multichannel analyzer).
International Nuclear Information System (INIS)
The spectrometric methods and equipment for "2"0"1Pb and "2"0"1Tl activity control in the prepared thallium chloride in industrial production are described. Estimation of thallium-201 activity is carried out in accord with the square of summary photopeak caused by #gamma#-quanta at 167 keV energy. Attenuation is paid to spectrometer calibration. 5 refs.; 2 figs.; 2 tabs.
Radiochemistry of lead-203 for radiolabelling antibody conjugates
International Nuclear Information System (INIS)
Lead-203 [52.1 h, 279 (80.1%) KeV] has been recognized as a potentially useful tracer for tumor specific radiopharmaceuticals due to its favorable nuclear and chemical properties. This paper reports the cyclotron production of lead-203 and the labelling of monoclonal antibody B72.3, conjugated with 2-(p-isothiocyanatobenzyl)DOTA, with lead-203 in 30% yield. In vivo biodistribution and stability studies in mice are being conducted.
1990-06-24
Quantitative phase imaging using hard x-rays
International Nuclear Information System (INIS)
The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.
2009-02-01
Portable real time neutron spectrometry II
International Nuclear Information System (INIS)
We describe the continued development of a portable, real-time neutron spectrometer. The spectrometer is composed of two distinct detector systems: a Helium 3 gas filled proportional counter for the lower neutron energy interval between 20 KeV and 2 MeV and a bulk silicon solid state detector for the higher energy interval between 2 MeV and 500 MeV. Modeling and experimental results with mono-energetic neutron beams are reported.
2000-01-19
Peculiarities of Swift Proton Transmission through Tapered Glass Capillaries
International Nuclear Information System (INIS)
A study of the 150-300 keV proton beam transmission through glass (borosilicate) tapered capillaries with different diameters of the input and output of the capillary was performed. The focusing effect was observed. The areal density of the transmitted beam is enhanced by approximately 20 times. It was shown that changing a taper angle from 0.5 deg to 1.7 deg evidences the increase of the transmission coefficient more than by 300 times keeping the initial energy spectrum of ions. (author)
2011-07-01
Optical and statistical model calculation of the americium 242m capture cross section
International Nuclear Information System (INIS)
The capture cross sections of Am 242m can be deduced from resonances analysis at low energy and computed with theoretical models at high energy. In this work, a coherent set of cross sections which reproduced the experimental values of the fission cross sections is computed. These calculations were performed for an energy of the incoming neutron between 1 keV and 1 MeV.
Molar extinction coefficients in aqueous solutions of some alkaline earth chlorides
International Nuclear Information System (INIS)
Molar extinction coefficients for the solid solutes in aqueous solutions of some alkaline earth chlorides such as MgCl_2.6H_2O, CaCl_2, SrCl_2.6H_2O and BaCl_2.2H_2O have been determined at 81, 356, 511, 662, 1173 and 1332 keV energies in different concentration using the narrow beam transmission methods. (author)
1999-12-21
Magnetic moments of "1"7"7Ta apd sup(181,182,187)Re states
International Nuclear Information System (INIS)
The magnetic moments of "1"7"7Ta and sup(181,182,187)Re levels decaying via the K-forbidden transitions are measured. The nuclei studied are produced via the "1"7"7W and sup(181,182)Os and "1"8"7W #beta#-decay respectively. The magnetic moments have been measured using the method of the differential #gamma##gamma# angular correlations, perturbed by an external magnetic field. The following magnetic moments and lifetimes are obtained: for the 5/2"-1/2"-[541] "1"8"1Re level with excitation energy of 357 keV #mu#/#mu#sub(n)=2.00+-0.10, Tsub(1/2)=(76+-8)x10sup(-8) s; for the 186.4 keV 5/2"-1/2"-[541] "1"7"7Ta level #mu#/#mu#sub(n)=2.02+-0.13, Tsub(1/2)=(2.78+-0.09)x10sup(-6) s; for the 236 keV 2"- "1"8"2Re level #mu#/#mu#sub(n)=2.12+-0.08; for the 203 keV 9/2"- [514] "1"8"7Re level #mu#/#mu#sub(n)=5.04+-0.09.
1978-03-01
Magnetic moment of the three-quasiparticle state in /sup 177/Ta
Energy Technology Data Exchange (ETDEWEB)
An experimental investigation was made of the ..gamma..-transitions feeding or de-exciting the 1355 keV isomeric state in /sup 177/Ta. The E2/M1 mixing ratios for the 311 keV interband transition from the isomer and for the 271 keV and the 295 keV intraband transitions within the rotational band on the isomer were determined to be delta = 0.29sup(+0.11)sub(-0.06), 0.25sup(+0.05)sub(-0.03) and 0.30sup(+0.06)sub(-0.08), respectively, employing combined measurements of the linear polarization and angular distribution of the ..gamma..-ray with the aid of conversion electron measurements. Spin and parity assignments of the isomer were confirmed to be 21/2/sup -/. The half-life of the isomer was remeasured to be Tsub(1/2) = 5.0 +- 0.2 ..mu..s and the magnetic moment was found to be ..mu.. = 0.080 +- 0.014 ..mu..sub(N). The gsub(K) and gsub(R) factors for the band on the isomer were deduced separately to be ...
1982-06-07
Magnetic moment of the three-quasiparticle state in "1"7"7Ta
International Nuclear Information System (INIS)
An experimental investigation was made of the #gamma#-transitions feeding or de-exciting the 1355 keV isomeric state in "1"7"7Ta. The E2/M1 mixing ratios for the 311 keV interband transition from the isomer and for the 271 keV and the 295 keV intraband transitions within the rotational band on the isomer were determined to be delta = 0.29sup(+0.11)sub(-0.06), 0.25sup(+0.05)sub(-0.03) and 0.30sup(+0.06)sub(-0.08), respectively, employing combined measurements of the linear polarization and angular distribution of the #gamma#-ray with the aid of conversion electron measurements. Spin and parity assignments of the isomer were confirmed to be 21/2"-. The half-life of the isomer was remeasured to be Tsub(1/2) = 5.0 +- 0.2 #mu#s and the magnetic moment was found to be #mu# = 0.080 +- 0.014 #mu#sub(N). The gsub(K) and gsub(R) factors for the band on the isomer were deduced separately to be gsub(K=21/2"-) = ...
Intensity of auger-emission of silicon from binary compounds in the ion auger spectroscopy
International Nuclear Information System (INIS)
Auger-electron emission from different silicides has been studied for 4 and 10 keV Ar ion excitation. The intensity of the SiLMM Auger line changes significantly with channing concentration and atomic number of the metal-parthner. The experimental results can be explained in terms of a simple model based on the probability of Si-Si collision symmetric cascade in these binary compounds.
Final Report: Planetary Instrument Definition and Design Program (PIDDP) Support Project
Energy Technology Data Exchange (ETDEWEB)
The results of Sandia National Laboratories' participation in the NASA Planetary Definition and Design Program are summarized. Areas reported include the characterization of large area cadmium zinc telluride spectrometers and the application of simulation techniques to the prediction of device performance. Also investigated was the response of mercuric iodide devices in the region from 1 to 100 KeV. A literature study to determine the status or radiation damage measurements in room temperature semiconductor devices is also reported.
1999-03-01
International Nuclear Information System (INIS)
The Ksub(#beta#)/Ksub(#alpha# 12) x-ray intensity ratio of the Si K spectrum was measured for proton impact on Si0_2 in the energy range 300-800 keV. An energy dependence of the intensity ratio was found and an explanation is given in terms of multiple ionisation. (author).
1980-04-01
Double-electron-capture cross section for I/sup +/ in a magnesium-vapor target
Energy Technology Data Exchange (ETDEWEB)
Measurements of the double-electron-capture process in which a positive ion of iodine becomes a negative ion in a single collision with a magnesium atom are reported between 20 and 90 keV. The cross section is comparable to that for the rare gases and not as large as might be expected from a two-valence-electron atom. This process is probably insignificant in the production of negative ion beams using a magnesium-vapor target.
1987-06-15
Energy Technology Data Exchange (ETDEWEB)
The INTEGRAL/SPI spectrometer was designed to observe the sky in the energy band of 20 keV to 8 MeV. The specificity of instrument SPI rests on the excellent spectral resolution (2.3 keV with 1 MeV) of its detecting plan, composed of 19 cooled germanium crystals; covering an effective area of 508 cm{sup 2}. The use of a coded mask, located at 1.7 m above the detection plan ensures to it a resolving power of 2.5 degrees. The aim of this thesis, begun before the INTEGRAL launch, is made up of two parts. The first part relates to the analysis of the spectrometer calibration data. The objective was to measure and check the performances of the telescope, in particular to validate simulations of the INTEGRAL/SPI instrument response. This objective was successfully achieved. This analysis also highlights the presence of a significant instrumental background noise. Whereas, the second part concentrates on the data analysis of the Vela region ...
2005-01-15
Decay of "1"0"1Mo and band structures of its daughter nuclide "1"0"1Tc in the projected shell model
International Nuclear Information System (INIS)
The decay of molybdenum-101 has been investigated using the three-parameter (#gamma#-#gamma#-t) coincidence system of HPGe-HPGe detectors. According to the off-line analysis, the decay scheme was modified. The positions of 221.80, 318.00, 377.90; 452.50, 515.42, 1011.05, and 1759.72 keV transitions have been arranged again, the transition positions of 104.70, 105.95, and 774.15 keV gamma rays have been assigned for the first time, the positions of 169.00, 590.91, 980.52, and 1431.68 keV transitions have been reconfirmed, and the 1508.01 keV gamma ray was observed simultaneously for the first time and its transition position has been assigned. The #beta#"- intensities and the values of log ft of most levels were calculated. Combining with the high-spin states observed by the in-beam #gamma#-ray spectroscopy of previous decay works, the structure of the excited positive/negative-parity yrast states of ...
2006-01-01
Complete spectroscopy of "8"7","8"8","8"9Sr with (n,#gamma#) and (d,p) reactions?
International Nuclear Information System (INIS)
We conducted (n, #gamma#) and (d, p) reactions leading to "8"7", "8"8", "8"9"Sr in addition to "8"8Sr (d, t) "8"7Sr and 24 keV neutron capture in "8"8Sr. (orig./HSI).
Chemical effects on L_#gamma#_1/L_#beta#_1 x-ray intensity ratio of molybdenum compounds
International Nuclear Information System (INIS)
Chemical effects on the intensity ratio of LX-ray of molybdenum compounds irradiated by 11-keV electrons and by 3-MeV protons were studied using an x-ray crystal spectrometer. It was found that the intensity ratios of L_#gamma#_1/L_#beta#_1 markedly decrease with the increase of ionicity of molybdenum compounds, except for the case of metallic molybdenum. (author).
1987-06-01
Energy Technology Data Exchange (ETDEWEB)
Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, spectrometry, kerma distributions, coupled multigroup calculations
1983-01-01
International Nuclear Information System (INIS)
Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, spectrometry, kerma distributions, coupled multigroup calculations.
7871-01-01
The solubility of hydrogen and deuterium in crystalline Pd{sub 9}Si{sub 2}
Energy Technology Data Exchange (ETDEWEB)
Isotherms have been measured for H(D){sub 2}(g) solution in crystalline Pd{sub 9}Si{sub 2} in the temperature range from 235 to 373 K. The solubilities are significant, e.g., at 1.0 MPa (298 K), (H/Pd) = 0.052 or Pd{sub 9}Si{sub 2}H{sub 0.47}, however, there is no indication of hydride phase formation even down to 235 K at 1.0 MPa. The thermodynamic values for hydrogen solutions at infinite dilution of hydrogen are {Delta}H{degrees}{sub H}= -11.9 kJ/mole {1/2}H{sub 2} and {Delta}S{degrees}{sub H} = -50 J/K mole {1/2}H{sub 2}. The former is more negative than for Pd-H{sub 2} and the latter is somewhat more positive; but generally the values are not that different from Pd-H{sub 2}. The isotope effect is similar to that found for Pd-H(D){sub 2}.
1995-11-15
Spectral dependence of ultrasonic attenuation for hydrided Zr-2.5%Nb Alloy
International Nuclear Information System (INIS)
The cold-worked Zr-2.5%Nb alloy is used as material for the pressure tubes in CANDU nuclear reactors. During the service life in reactor, diffusion of hydrogen and/or deuterium in the pressure tubes wall occur. Below a certain temperature, a stable hydride of zirconium is formed, as a brittle phase which can lead to catastrophic failures. For this reason, it is very important to be able to investigate the hydrogen effect on the micro structural properties of zirconium alloys. In the present paper a non-destructive testing technique is used, known as ultrasonic spectral analysis. When an ultrasonic signal traverses a medium, the frequency components associated with the input signal are altered. By frequency analysing the reflected signals, it is possible to study and compare the material properties. The two major parameters measured in ultrasonic spectroscopy are the attenuation and the velocity of the waves. Attenuation is determined by the energy losses in ...
2009-10-12
Energy Technology Data Exchange (ETDEWEB)
The use of deuterium-tritium fuel in the Compact Ignition Tokamak will require applying remote handling technology for ex-vessel maintenance and replacement of machine components. Highly activated and contaminated components of the fusion devices auxiliary systems, such as diagnostics and RF heating, must be replaced using remotely operated maintenance equipment in the test cell. In-vessel remote maintenance included replacement of divertor and first wall hardware, faraday shields, and for an in-vessel inspection system. Provision for remote replacement of a vacuum vessel sector, toroidal field coil or poloidal field ring coil was not included in the project baseline. As a result of recent coil failures experienced at a number of facilities, the CIT project decided to reconsider the question of remote recovery from a coil failure and, in January of 1990, initiated a coil replacement study. This study focused on the technical requirements and impact on fusion ...
1990-01-01
Progress of the DUPIC Fuel Compatibility Analysis (IV) - Fuel Performance
International Nuclear Information System (INIS)
This study describes the mechanical compatibility of the direct use of spent pressurized water reactor (PWR) fuel in Canada deuterium uranium (CANDU) reactors (DUPIC) fuel, when it is loaded into a CANDU reactor. The mechanical compatibility can be assessed for the fuel management, primary heat transport system, fuel channel, and the fuel handling system in the reactor core by both the experimental and analytic methods. Because the physical dimensions of the DUPIC fuel bundle adopt the CANDU flexible (CANFLEX) fuel bundle design which has already been demonstrated for a commercial use in CANDU reactors, the experimental compatibility analyses focused on the generation of material property data and the irradiation tests of the DUPIC fuel, which are used for the computational analysis. The intermediate results of the mechanical compatibility analysis have shown that the integrity of the DUPIC fuel is mostly maintained under the high power and high burnup conditions ...
1995-06-04
Production of negative ions by electron impact. Final report 1 May 81-31 Oct 82
Proposed future space-based beam weapons systems will most probably require an intense neutral particle beam for effective operation across geomagnetic field lines. Such neutral beams can most efficiently be obtained by stripping excess electrons from negative ion beams. The objective of this work is to study the process of dissociative attachment of electrons. Specifically, to measure the cross sections for polar dissociation and dissociative attachment for production of H(-). It is suspected that these dissociative attachment cross sections for the production of H(-) from alkali hydrides are large. The insight gained from this study will be extremely helpful in the fabrication of high current density H(-) beam sources for use in the production of intense neutral hydrogen beams. A selection of alkali hydride molecules will be investigated in order to determine the largest cross sections for the production of H(-) by electron impact. The angular distribution of the H(-) ions will be ...
1982-10-01
New intelligent monitor for CANDU type NPP
International Nuclear Information System (INIS)
Nuclear energy provides a third of Europe's electricity with nearly no greenhouse-gas emissions. Sustained efforts are now being conducted to harmonize regulations all over Europe through WENRA and to converge on technical nuclear safety practices within the TSO network ETSON (European Technical Safety Organizations Network). In CANDU type NPP the tritiated water occurs by the neutron bombardment of deuterium. The tritiated water vapors imply health hazard (in the critical organs of the body the water presents a 10 day average biological half-life) and the early detection in nuclear plants of tritium emissions is important because the tritiated water vapors have the same characteristics as of atmospheric water vapors. By detecting tritiated vapors, the monitoring system ensures the following objectives: (a) indicates levels of tritium generally due to heavy water leakage, (b) reduces the possibility of health hazard. In order to attain this goal of safety function, ...
2009-10-12
Identification of recharge sources and dating of groundwater using isotope and CFC techniques
International Nuclear Information System (INIS)
Due to severe drought conditions in Pakistan over the past several years, most of the areas are facing extinction of its potable water reserves and inadequate replenishment of groundwater aquifers. Due to over exploitation, the groundwater flow dynamics is changing and water quality is degrading due to induced infiltration from polluted surface sources. Isotope hydrology is relatively a new discipline having great potential for studying various water-related problems. RIAD, PINSTECH has established analytical facilities for commonly used environmental isotopes and applied to investigate various hydrological problems. This paper briefly describes practical examples on recharge mechanism and dating of groundwater in Lahore and Ziarat areas using isotopes like deuterium (/sup 2/H), Oxygen-18 (/sup 18/O), Tritium (/sup 3/H) and CFCs in water. In Lahore, the areas having different contribution of the river Ravi in groundwater recharge have been marked and on the basis ...
2004-06-07
Experimental investigation on the fretting wear of alloy 800 in room remperature water
Energy Technology Data Exchange (ETDEWEB)
Fretting wear test in room temperature water was performed to evaluate the wear coefficient of CANDU (CANadian Deuterium Uranium) steam generator (SG) tube material (Alloy 800) against 410 type martensitic stainless steels. The main focus is to compare the wear behaviors between Alloy 800 and Inconel 690. Test conditions are 10{approx}30N of normal load, 200{approx}450mm of sliding amplitude and 30Hz of frequency. The result indicated that the wear rate of Alloy 800 was higher than those of Inconel 690 at various test condition such as normal loads, sliding amplitudes etc. From the results of SEM observation, there was little evidence of plastic deformation layer that were dominantly formed on the worn surfaces of Inconel 690. Also, wear particles in Alloy 800 were released from contacting asperities deformed by severe plastic flow during fretting wear. Main cause of wear rate between Alloy 800 and Inconel 690 may be due to the difference of hardness between ...
2002-05-01
Experimental investigation on the fretting wear of alloy 800 in room remperature water
International Nuclear Information System (INIS)
Fretting wear test in room temperature water was performed to evaluate the wear coefficient of CANDU (CANadian Deuterium Uranium) steam generator (SG) tube material (Alloy 800) against 410 type martensitic stainless steels. The main focus is to compare the wear behaviors between Alloy 800 and Inconel 690. Test conditions are 10#approx#30N of normal load, 200#approx#450mm of sliding amplitude and 30Hz of frequency. The result indicated that the wear rate of Alloy 800 was higher than those of Inconel 690 at various test condition such as normal loads, sliding amplitudes etc. From the results of SEM observation, there was little evidence of plastic deformation layer that were dominantly formed on the worn surfaces of Inconel 690. Also, wear particles in Alloy 800 were released from contacting asperities deformed by severe plastic flow during fretting wear. Main cause of wear rate between Alloy 800 and Inconel 690 may be due to the difference of hardness between ...
2002-05-01
Effective multiplication factor measurement by feynman-{alpha} method. 3
Energy Technology Data Exchange (ETDEWEB)
The sub-criticality monitoring system has been developed for criticality safety control in nuclear fuel handling plants. In the past experiments performed with the Deuterium Critical Assembly (DCA), it was confirmed that the detection of sub-criticality was possible to k{sub eff} = 0.3. To investigate the applicability of the method to more generalized system, experiments were performed in the light-water-moderated system of the modified DCA core. From these experiments, it was confirmed that the prompt decay constant ({alpha}), which was a index of the sub-criticality, was detected between k{sub eff} = 0.623 and k{sub eff} = 0.870 and the difference of 0.05 - 0.1{Delta}k could be distinguished. The {alpha} values were numerically calculated with 2D transport code TWODANT and monte carlo code KENO V.a, and the results were compared with the measured values. The differences between calculated and measured values were proved to be less than 13%, which was sufficient ...
1998-06-01
Energy Technology Data Exchange (ETDEWEB)
The determination of the banned anabolic substance zeranol and the metabolites taleranol and zearalanone in bovine urine is complicated by the occurrence of the structurally-related mycotoxin zearalenone and the corresponding {alpha}- and {beta}-zearalenol metabolites which possess similar estrogenic properties. A liquid chromatography-negative ion electrospray tandem mass spectrometric method is presented for the confirmatory analysis of all six resorcylic acid lactones ('zeranols') in urine samples using deuterium-labelled internal standards. The method was validated as a confirmatory method for bovine urine samples according to new draft EU guidelines and showed good precision and linearity, and CC{alpha} and CC{beta} values of 0.02-0.30 and <1.0 ng ml{sup -1}, respectively. The applicability was demonstrated by comparing the results of an incurred sample with previous results on the same sample obtained by gas chromatography high ...
2002-11-25
BNL Neutral Beam Development Group. Progress report, FY 1983 and final report
Energy Technology Data Exchange (ETDEWEB)
The BNL Neutral Beam Development Group has been active in the program for the development of high energy, high power neutral beam systems since 1973. These injectors are based on the production, acceleration and neutralization of negative hydrogen or deuterium ions and are supposed to be used for plasma heating and current drive in the next generation of fusion devices. Over the span of 10 years the group has studied plasma-surface type of negative hydrogen ion sources, transport and acceleration of negative ion beams and neutralization of negative ions in gases and plasmas. As the required source parameters (current, pulse length, efficiency) were changing over this period of time, the group developed several types of sources, resulting finally in the design of a steady state device operating with an excellent gas efficiency and having the possibility of scaling-up to the size necessary for a high power neutral beam system. The funding of this program was, ...
1984-03-16
Analysis of the requirements for economic magnetic fusion
Energy Technology Data Exchange (ETDEWEB)
A generic reactor model is used to examine the economic viability of electricity generation by magnetic fusion. The simple model uses components which are representative of those used in previous reactor studies of deuterium-tritium burning tokamaks, stellarators, bumpy tori, reverse field pinches and tandem mirrors. Conservative costing assumptions are made. The generic reactor is not a tokamak but rather it is intended to emphasize what is common to all magnetic fusion reactors. The reactor uses a superconducting toroidal coil set to produce the dominant magnetic field. To this extent it is a less good approximation to systems, such as the reversed field pinch in which the main field is produced by a plasma current. The main output of the study is the cost of electricity as a function of the weight and size of the fusion core - blanket, shield, structure and coils. The model shows that a 1200 MW/sub e/ power plant with a fusion core weight of about 10,000 tonnes ...
1986-01-01
All-atom molecular dynamics simulations using orientational constraints from anisotropic NMR samples
Orientational constraints obtained from solid state NMR experiments on anisotropic samples are used here in molecular dynamics (MD) simulations for determining the structure and dynamics of several different membrane-bound molecules. The new MD technique is based on the inclusion of orientation dependent pseudo-forces in the COSMOS-NMR force field. These forces drive molecular rotations and re-orientations in the simulation, such that the motional time-averages of the tensorial NMR properties approach the experimentally measured parameters. The orientational-constraint-driven MD simulations are universally applicable to all NMR interaction tensors, such as chemical shifts, dipolar couplings and quadrupolar interactions. The strategy does not depend on the initial choice of coordinates, and is in principle suitable for any flexible molecule. To test the method on three systems of increasing complexity, we used as constraints some deuterium quadrupolar couplings from ...
2007-03-03
All-atom molecular dynamics simulations using orientational constraints from anisotropic NMR samples
Energy Technology Data Exchange (ETDEWEB)
Orientational constraints obtained from solid state NMR experiments on anisotropic samples are used here in molecular dynamics (MD) simulations for determining the structure and dynamics of several different membrane-bound molecules. The new MD technique is based on the inclusion of orientation dependent pseudo-forces in the COSMOS-NMR force field. These forces drive molecular rotations and re-orientations in the simulation, such that the motional time-averages of the tensorial NMR properties approach the experimentally measured parameters. The orientational-constraint-driven MD simulations are universally applicable to all NMR interaction tensors, such as chemical shifts, dipolar couplings and quadrupolar interactions. The strategy does not depend on the initial choice of coordinates, and is in principle suitable for any flexible molecule. To test the method on three systems of increasing complexity, we used as constraints some deuterium quadrupolar couplings from ...
2007-05-15
All-atom molecular dynamics simulations using orientational constraints from anisotropic NMR samples
International Nuclear Information System (INIS)
Orientational constraints obtained from solid state NMR experiments on anisotropic samples are used here in molecular dynamics (MD) simulations for determining the structure and dynamics of several different membrane-bound molecules. The new MD technique is based on the inclusion of orientation dependent pseudo-forces in the COSMOS-NMR force field. These forces drive molecular rotations and re-orientations in the simulation, such that the motional time-averages of the tensorial NMR properties approach the experimentally measured parameters. The orientational-constraint-driven MD simulations are universally applicable to all NMR interaction tensors, such as chemical shifts, dipolar couplings and quadrupolar interactions. The strategy does not depend on the initial choice of coordinates, and is in principle suitable for any flexible molecule. To test the method on three systems of increasing complexity, we used as constraints some deuterium quadrupolar couplings from ...
2007-05-01
Energy Technology Data Exchange (ETDEWEB)
This dissertation describes a measurement of the rate ofnuclear muon capture by the proton, performed by the MuCap Collaborationusing a new technique based on a time projection chamber operating inultraclean, deuterium-depleted hydrogen gas at room temperature and 1 MPapressure. The hydrogen target's low gas density of 1 percent compared toliquid hydrogen is key to avoiding uncertainties that arise from theformation of muonic molecules. The capture rate was obtained from thedifference between the mu- disappearance rate in hydrogen--as determinedfrom data collected in the experiment's first physics run in fall2004--and the world averagefor the mu+ decay rate. After combining theresults of my analysis with the results from another independent analysisof the 2004 data, the muon capture rate from the hyperfine singlet groundstate of the mu-p atom is found to be Lambda_S = 725.0 +- 17.4 1/s, fromwhich the induced pseudoscalar coupling of the nucleon, ...
2007-07-10
Transient enhanced diffusion of Sb and B due to MeV silicon implants
Energy Technology Data Exchange (ETDEWEB)
We measure the transient enhanced diffusion of shallow molecular-beam-epitaxy grown marker layers of Sb and B due to deep MeV Si{sup +} ion implants at very high doses ({approx}10{sup 16}cm{sup {minus}2}). We expect the near-surface region of these implants to be vacancy rich, and we observe transient enhanced diffusion of Sb (the classic vacancy diffuser). The large enhancements imply a significant vacancy supersaturation ({approx}700 at 740{degree}C). Double implantation of the high-dose MeV Si followed by a shallow (40 keV) Si implant and annealing produces a greatly reduced number of {l_brace}311{r_brace} defects compared to a 40 keV implant into virgin Si, again consistent with a vacancy-rich region in the near-surface region of an MeV implant. However, the shallow B marker layers also show transient enhanced diffusion for the same MeV implant under similar annealing conditions, implying that an interstitial supersaturation is present at ...
1997-06-01
Transient enhanced diffusion of Sb and B due to MeV silicon implants
International Nuclear Information System (INIS)
We measure the transient enhanced diffusion of shallow molecular-beam-epitaxy grown marker layers of Sb and B due to deep MeV Si"+ ion implants at very high doses (#approx#10"1"6cm"-"2). We expect the near-surface region of these implants to be vacancy rich, and we observe transient enhanced diffusion of Sb (the classic vacancy diffuser). The large enhancements imply a significant vacancy supersaturation (#approx#700 at 740 degree C). Double implantation of the high-dose MeV Si followed by a shallow (40 keV) Si implant and annealing produces a greatly reduced number of #left brace#311#right brace# defects compared to a 40 keV implant into virgin Si, again consistent with a vacancy-rich region in the near-surface region of an MeV implant. However, the shallow B marker layers also show transient enhanced diffusion for the same MeV implant under similar annealing conditions, implying that an interstitial supersaturation is present at the same ...
International Nuclear Information System (INIS)
High-power arc lamp design has enabled ultrahigh-temperature (UHT) annealing as an alternative to conventional rapid thermal processing (RTP) for ultrashallow junction formation. The time duration of the UHT annealing technique is significantly reduced from those obtained through conventional RTP. This difference in time may offer the ability to maintain a highly activated ultrashallow junction without being subjected to transient enhanced diffusion (TED), which is typically observed during postimplant thermal processing. In this study, two 200-mm (100) n-type Czochralski-grown Si wafers were preamorphized with either a 48- or a 5-keV Ge"+ implant to 5x10"1"4 cm"2, and subsequently implanted with 3-keV BF_2"+ molecular ions to 6x10"1"4 cm"2. The wafers were sectioned and annealed under various conditions in order to investigate the effects of the UHT annealing technique on the resulting junction characteristics. The main point of the paper is ...
2005-02-15
The effect of boron implant energy on transient enhanced diffusion in silicon
Energy Technology Data Exchange (ETDEWEB)
Transient enhanced diffusion (TED) of boron in silica after low energy boron implantation and annealing was investigated using boron-doping superlattices (DSLs) grown by low temperature molecular beam epitaxy. Boron ions were implanted at 5, 10, 20, and 40 keV at a constant dose of 2{times}10{sup 14}/cm{sup 2}. Subsequent annealing was performed at 750{degree}C for times of 3 min, 15 min, and 2 h in a nitrogen ambient. The broadening of the boron spikes was measured by secondary ion mass spectroscopy and simulated. Boron diffusivity enhancement was quantified as a function of implant energy. Transmission electron microscopy results show that {l_angle}311{r_angle} defects are only seen for implant energies {ge}10 keV at this dose and that the density increases with energy. DSL studies indicate the point defect concentration in the background decays much slower when {l_angle}311{r_angle} defects are present. These results imply there are at least ...
1997-02-01
Suzaku and Optical Spectroscopic Observations of SS 433 in the 2006 April Multiwavelength Campaign
We report results of the 2006 April multi-wavelengths campaign of SS 433, focusing on X-ray data observed with Suzaku at two orbital phases (in- and out-of- eclipse) and simultaneous optical spectroscopic observations. By analyzing the Fe25 K_alpha lines originating from the jets, we detect rapid variability of the Doppler shifts, dz/dt ~ 0.019/0.33 day^-1, which is larger than those expected from the precession and/or nodding motion. This phenomenon probably corresponding to "jitter" motions observed for the first time in X-rays, for which significant variability both in the jet angle and intrinsic speed is required. From the time lag of optical Doppler curves from those of X-rays, we estimate the distance of the optical jets from the base to be ~(3-4) \\times 10^14 cm. Based on the radiatively cooling jet model, we determine the innermost temperature of the jets to be T_0 = 13 +/- 2 keV and 16 +/- 3 keV (the average of the blue and red jets) ...
2010-01-01
Sr-88 and Y-89 - The s-process at magic neutron number N = 50
Energy Technology Data Exchange (ETDEWEB)
The neutron capture cross sections of Sr-88 and Y-89 were measured in a quasi-stellar neutron spectrum for kT = 25 keV via the activation method. Relevant systematic uncertainties were determined experimentally by repeated activations under different conditions and with different samples. Gold was used as a cross section standard. The resulting stellar cross sections for kT = 30 keV are 6.13 + or - 0.18 mbarn for Sr-88 and 19.0 + or - 0.6 mbarn for Y-89. The partial cross section Sr-86(n, gamma) Sr-87m was measured to 48.1 + or - 1.2 mbarn. Compared to previous data, the associated uncertainties are reduced by factors of 3 and 5, respectively. The implications for s-process nucleosynthesis around magic neutron number N = 50 are discussed in the light of new information on neutron density and temperature. 38 refs.
1990-05-01
Sr-88 and Y-89 - The s-process at magic neutron number N = 50
International Nuclear Information System (INIS)
The neutron capture cross sections of Sr-88 and Y-89 were measured in a quasi-stellar neutron spectrum for kT = 25 keV via the activation method. Relevant systematic uncertainties were determined experimentally by repeated activations under different conditions and with different samples. Gold was used as a cross section standard. The resulting stellar cross sections for kT = 30 keV are 6.13 + or - 0.18 mbarn for Sr-88 and 19.0 + or - 0.6 mbarn for Y-89. The partial cross section Sr-86(n, gamma) Sr-87m was measured to 48.1 + or - 1.2 mbarn. Compared to previous data, the associated uncertainties are reduced by factors of 3 and 5, respectively. The implications for s-process nucleosynthesis around magic neutron number N = 50 are discussed in the light of new information on neutron density and temperature. 38 refs.
Sr-88 and Y-89 - The s-process at magic neutron number N = 50
The neutron capture cross sections of Sr-88 and Y-89 were measured in a quasi-stellar neutron spectrum for kT = 25 keV via the activation method. Relevant systematic uncertainties were determined experimentally by repeated activations under different conditions and with different samples. Gold was used as a cross section standard. The resulting stellar cross sections for kT = 30 keV are 6.13 + or - 0.18 mbarn for Sr-88 and 19.0 + or - 0.6 mbarn for Y-89. The partial cross section Sr-86(n, gamma) Sr-87m was measured to 48.1 + or - 1.2 mbarn. Compared to previous data, the associated uncertainties are reduced by factors of 3 and 5, respectively. The implications for s-process nucleosynthesis around magic neutron number N = 50 are discussed in the light of new information on neutron density and temperature.
1990-05-01
Recent neutron scattering work at the University of Lowell
International Nuclear Information System (INIS)
Neutron elastic and inelastic scattering cross sections of _2_3_8U and _2_3_2Th have been measured at the University of Lowell for states below 1.8 MeV. A time-of-flight (TOF) spectrometer was used. The disc-shaped scatterer was oriented to optimize energy resolutions for 200-to-500-keV neutrons. Neutrons were obtained via the _7Li(p,n)_7Be reaction. Targets were prepared by in-situ evaporation of Li onto a Ta backing. During the evaporation, the target thickness was monitored using a 5-m-flight-path TOF spectrometer; a typical target had a neutron thickness from 8 to 10 keV for Esub(p) = 2.25.MeV. Spectra were analyzed using the unfolding code TINA; standard peak shapes were obtained from codes LAGUE and LAPA. Results obtained will be presented.
1981-11-23
Particle-hole strength excited in the /sup 40/Ca(p,n)/sup 40/Sc reaction at 134 MeV
International Nuclear Information System (INIS)
The /sup 40/Ca(p,n)/sup 40/Sc reaction was studied at 134 MeV. Neutron energy spectra were measured by the time-of-flight technique with resolutions of 220 keV at angles from 0"0 to 41"0 and 415 keV out to 62"0. The 2"-,3"-,4"-,5"- band of states based on the (f/sub 7/2/,d/sub 3/2//sup -1/) 1p1h structure was observed at low excitation energies, in good agreement with known analog states in /sup 40/Ca and /sup 40/K. The shapes of the cross-section and analyzing-power angular distributions are in good agreement with distorted-wave impulse-approximation calculations using simple 1p1h (Tamm-Dancoff approximation) shell-model wave functions. A relatively strong transition to a state at E/sub x/ = 2.3 MeV with L = 3 is identified tentatively as a 4"- state with the predominant 1p1h structure (1f/sub 7/2/,2s/sub 1/2//sup -1/).
Oxygen-concentration dependent enhancement of positive secondary ion emission from silicon
Energy Technology Data Exchange (ETDEWEB)
The enhancement of positive secondary ion yields of silicon due to the presence of oxygen has been investigated quantitatively by low-energy (5 keV) oxygen implantation. Implantation and sputter profiling with 9 keV In/sup +/ were performed in the same ion microprobe instrument. Depth profiles of substrate and implanted oxygen atoms were measured for fluences ranging from 5x10/sup 15/ to 4x10/sup 16/ O-atoms/cm/sup 2/. The oxygen concentration, c(O), in the sample was deduced from the implanted fluence and the range distribution in the Gaussian approximation. It was found that the oxygen-enhanced Si/sup +/ intensity is proportional to c(O)sup(x) (with x=1.4) in the concentration regime, 1.5<=c(O)<=30 at%. The O/sup +/ intensity shows a similar dependence for c(O)> or approx.20 at.%.
1983-12-15
Optimization of advanced PMOS junctions using Ge, B and F co-implants
International Nuclear Information System (INIS)
The main challenges for PMOS ultra shallow junction formation remain the transient enhanced diffusion (TED) and the solid solubility limit of boron in silicon. It has been demonstrated that low energy boron implantation and spike annealing are key in meeting the 90nm technology node ITRS requirements. To meet the 65nm technology requirements many studies have used fluorine co-implantation with boron and Si"+ or Ge"+ pre-amorphization (PAI) and spike annealing. Although using BF_2"+ can be attractive for its high throughput, self-amorphization and the presence of fluorine, many studies have shown that the fluorine successfully reduce TED, its energy needs to be well optimized with respect to the boron's, therefore BF_2"+ does not present the right fluorine/boron energy ratio for the optimum junction formation. In this work we optimize the fluorine energy for boron energies down to 200eV. We show the dependence of optimized junction on Ge"+ energies of 2keV and ...
2005-08-01
Microstructures for high-energy x-ray and particle-imaging applications
Energy Technology Data Exchange (ETDEWEB)
Coded imaging techniques using thick, micro-Fresnel zone plates as coded apertures have been used to image x-ray emissions (2-20 keV) and 3.5 MeV Alpha particle emissions from laser driven micro-implosions. Image resolution in these experiments was 3-8 ..mu..m. Extension of this coded imaging capability to higher energy x-rays (approx. 100 keV) and more penetrating charged particles (e.g. approx. 15 MeV protons) requires the fabrication of very thick (50-200 ..mu..m), high aspect ratio (10:1), gold Fresnel zone plates with narrow linewidths (5-25 ..mu..m) for use as coded aperatures. A reactive ion etch technique in oxygen has been used to produce thick zone plate patterns in polymer films. The polymer patterns serve as electroplating molds for the subsequent fabrication of the free-standing gold zone plate structures.
1981-05-01
Microstructures for high-energy x-ray and particle imaging applications
Energy Technology Data Exchange (ETDEWEB)
Coded imaging techniques using thick, micro-Fresnel zone plates as coded apertures have been used to image x-ray emission (2--20 keV) and 3.5 MeV Alpha particle emissions from laser driven micro-implosions. Image resolution in these experiments was 3--8 ..mu..m. Extension of this coded imaging capability to higher energy x rays (approx.100 KeV) and more penetrating charged particles (e.g., approx.15 MeV protons) requires the fabrication of very thick (50--200 ..mu..m), high aspect ratio (10:1), gold Fresnel zone plates with narrow linewidths (5--25 ..mu..m) for use as coded apertures. A reactive ion etch technique in oxygen has been used to produce thick zone plate patterns in polymer films. The polymer patterns serve as electroplating molds for the subsequent fabrication of the free-standing gold zone plate structures.
1981-11-01
Microfabrication processes for high-T_c superconducting films
International Nuclear Information System (INIS)
Microfabrication processes for Y-Ba-Cu-O films have been investigated, using ion-beam techniques. High-T_c superconducting lines as narrow as 0.8 #mu#m have been fabricated from epitaxial YBa_2Cu_3O_7 _- _y films by Ar ion-beam etching (IBE), combined with focused ion-beam (FIB) lithography. The resulting lines, 1.3 #mu#m wide and 2 mm long, showed a zero resistance temperature of 81 K and a critical current density of 1.9 x 10"4 A/cm"2 at 77.3 K. Maskless etching was carried out using 130-keV au"+ focused ion-beam (FIB) with a 0.1-#mu#m-diameter beam. A 50-nm-thick film was patterned into 0.3-#mu#m-wide lines at a dose of 5 x "1"6 ions/cm"2. In comparison with Ar IBE, Cl_2 reactive ion-beam etching (RIBE) exhibited an enhancement effect in sputtering yield. Ion implantation with 300-keV Si"+ "+ FIB also indicated the possibility to produce submicrometer patterns by selectively modifying film properties from superconductive to normal or ...
International Nuclear Information System (INIS)
The effect of the #+-# 0.75 T external magnetic field on the K_#alpha#_1, K_#alpha#_2, K_#beta#_'_1 and K_#beta#_'_2 x-ray production cross sections and radiative vacancy transfer probabilities from K-shell to L2 and L3 subshells and M-shell for ferromagnetic Nd, Gd and Dy and paramagnetic Eu and Ho have been investigated, using the 59.5 keV incident photons. K-shell fluorescence yields and K x-ray intensity ratios for these elements have been determined in the external magnetic field also. The K x-rays from different targets were detected using a high-resolution Si(Li) semiconductor detector. For B = 0, the present experimental results were compared with the experimental and theoretical data in the literature. The results show that K-shell fluorescence parameters such as photoionization cross section, fluorescence yield, radiation rates, vacancy transfer probabilities and spectral linewidth can change owing to the applied magnetic field. (authors)
2006-06-19
Measurement of the /SUP 242m/ Am neutron fission cross section
Energy Technology Data Exchange (ETDEWEB)
The fission cross section of /SUP 242m/ Am has been measured from 0.005 eV to 20 MeV using time-of-flight techniques at the Oak Ridge Electron Linear Accelerator. A hemispherical plate fission ionization chamber with five pairs of plates contained three deposits totaling 507 ..mu..g of /SUP 242m/ Am, one deposit of 168 ..mu..g /sup 235/U, and a ''weightless'' deposit of /sup 252/Cf, which served as a monitor of chamber performance. The fission of /sup 235/U, served as the cross-section standard for energies above 101 keV while /sup 6/Li(n,..cap alpha..), normalized to /sup 235/U fission in the 7.8- to 11.0-eV interval, served as a shape standard below 101 keV. Approximately 360 h of data were obtained at a flight path distance of 9.1 m, primarily with 40-ns bursts. Particular attention was paid to correction of backgrounds, especially inscattered-neutron-induced events. The fission resonance integral was ...
1983-05-01
Measurement of the /SUP 242m/ Am neutron fission cross section
International Nuclear Information System (INIS)
The fission cross section of /SUP 242m/ Am has been measured from 0.005 eV to 20 MeV using time-of-flight techniques at the Oak Ridge Electron Linear Accelerator. A hemispherical plate fission ionization chamber with five pairs of plates contained three deposits totaling 507 #mu#g of /SUP 242m/ Am, one deposit of 168 #mu#g "2"3"5U, and a ''weightless'' deposit of "2"5"2Cf, which served as a monitor of chamber performance. The fission of "2"3"5U, served as the cross-section standard for energies above 101 keV while "6Li(n,#alpha#), normalized to "2"3"5U fission in the 7.8- to 11.0-eV interval, served as a shape standard below 101 keV. Approximately 360 h of data were obtained at a flight path distance of 9.1 m, primarily with 40-ns bursts. Particular attention was paid to correction of backgrounds, especially inscattered-neutron-induced events. The fission resonance integral was found to be 1800 + or - 65 b.
Measurement of relative L X-ray intensity ratio following radioactive decay and photoionization
International Nuclear Information System (INIS)
The measurements of the L X-ray intensity ratio I(L?)/I(L?), I(L?)/I(L?), I(L?)/I(L?), I(L?)/I(L?) and I(L?)/I(L?) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV ?-rays from a filtered radioisotope 241Am was used, and by the radioactive decay of 160Tb, 160Er, 173Lu, 182Re, 201Tl, 203Pb and 207Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L?/L?), I(L?/L?), I(L?/L?), I(L?/L?) and I(L?/L?) intensity ratios were calculated using theoretically tabulated values of subshell photoionization cross-section, fluorescence yield, fractional X-ray emission rates, Coster-Kronig transition probabilities. It was observed that present values agree with previous theoretical and other available experimental results.
2008-05-22
British Library Electronic Table of Contents (United Kingdom)
The L shell fluorescence cross-sections of the elements in range 45Z50 have been determined at 8keV using Synchrotron radiation. The individual L X-ray photons, Ll, La, LbI, LbII, LgI and LgII produced in the target were measured with high resolution Si(Li) detector. The experimental set-up provided a low background by using linearly polarized monoenergetic photon beam, improving the signal-to-noise ratio. The experimental cross-sections obtained in this work were compared with available experimental data from Scofield [1,2] Krause [3,4] and Scofield and Puri et al. [5,6]. These experimental values closely agree with the theoretical values calculated using Scofield and Krause data, except for the case of Lg, where values measured of this work are slighter higher.
2011-01-01
Ion beam mixing in Fe/Si and Ta/Si bilayers: Possible effects of ion charges
Energy Technology Data Exchange (ETDEWEB)
Thin Fe and Ta layers of 30-45 nm thickness, deposited via magnetron sputtering on Si (1 0 0) substrates, were bombarded at room temperature with 100 keV Ar{sup 1+} or Ar{sup 8+} or with 250 keV Xe{sup 1+} or Xe{sup 19+} ions in order to test the influence of the ion charge state on the surface sputtering and interface mixing. The samples were characterized by means of Rutherford backscattering at 0.9-3.0 MeV {alpha}-particle energy, time-of-flight elastic recoil detection analysis with a 53 MeV {sup 127}I{sup 10+} beam and atomic force microscopy. No influence of the charge state on the sputtering and athermal mixing rate was observed in the case of the Ta/Si system. However, in the case of the Fe/Si system, the ion charge was observed to have an influence on the mixing rate.
2003-05-01
Integration and Testing of the Micro-X Rocket Payload
The Micro-X instrument is a rocket borne, X-ray imaging spectrometer planned for launch in October 2011. An array of 128 Transition Edge Sensors (TESs) on a 600 micron pitch will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. X-rays will be focused onto the TES array by a conically approximated Wolter optic with an effective area of 300 cm^2 giving the instrument a field of view of 11.8 arcmin. This performance will constitute a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat bath, and will be read out by a SQUID time division multiplexer. The first flight of the Micro-X instrument will observe the Puppis A supernova remnant. Future targets include the core of ...
2011-05-01
Energy Technology Data Exchange (ETDEWEB)
For an assessment of the future US spallation neutron source (SNS) target performance, radiation induced hardening and microstructural evolution were investigated as a function of ion dose for EC316LN stainless steel. Irradiation was carried out using 3.5 MeV Fe{sup +}, 360 keV He{sup +}, and 180 keV H{sup +} simultaneous ion-beams at 200 deg. C to simulate the damage, He and H production in the SNS target vessel wall. At low dose (< 1 dpa), the predominant defects were black dots whose number density saturated rapidly within a few dpa. This was followed by the evolution of interstitial loops whose number density saturated below 15 dpa. Although He-bubbles were not visible, severely scalloped loops suggested that the implanted He/H atoms existed in the form of small clusters. Comparison with reported neutron irradiation data showed that hardening and ductility loss occurred mostly in the black dot regime (< 1 dpa), but that good ...
2000-04-01
International Nuclear Information System (INIS)
For an assessment of the future US spallation neutron source (SNS) target performance, radiation induced hardening and microstructural evolution were investigated as a function of ion dose for EC316LN stainless steel. Irradiation was carried out using 3.5 MeV Fe"+, 360 keV He"+, and 180 keV H"+ simultaneous ion-beams at 200 deg. C to simulate the damage, He and H production in the SNS target vessel wall. At low dose (< 1 dpa), the predominant defects were black dots whose number density saturated rapidly within a few dpa. This was followed by the evolution of interstitial loops whose number density saturated below 15 dpa. Although He-bubbles were not visible, severely scalloped loops suggested that the implanted He/H atoms existed in the form of small clusters. Comparison with reported neutron irradiation data showed that hardening and ductility loss occurred mostly in the black dot regime (< 1 dpa), but that good ductility (>20% ...
2000-04-01
International Nuclear Information System (INIS)
The energy resolution of small NaI(Tl), CsI(Tl), BGO, GSO, YAP and LSO crystals has been studied using 16 mm diameter large area avalanche photodiodes (LAAPD) and a 52 mm diameter photomultiplier. The best result of 4.8% for 662 keV #gamma#-rays from a "1"3"7Cs source was obtained with a 9 mm in diameter by 9 mm high CsI(Tl) scintillator coupled to an LAAPD. Measuring the number of primary electron-hole pairs produced in the LAAPD and photoelectrons in the photomultiplier, as well as the noise contribution of the LAAPD, allowed a quantitative discussion of the results. The energy resolutions measured with LAAPDs are comparable to, or significantly better (at certain emission wavelengths) than, those obtained with the photomultiplier. At energies above 100 keV the energy resolution measured with the majority of crystals and the LAAPD was weakly affected by the photodiode noise contribution. The advantages and limitations of LAAPDs in energy ...
1998-06-01
Effect of the Ge preamorphization dose on boron diffusion and defect evolution in silicon
Energy Technology Data Exchange (ETDEWEB)
In this paper, we study the effect of the Ge{sup +} preamorphization dose on boron diffusion and on the thermal evolution of end of range (EOR) defects during annealing. Amorphizations were carried out by implanting Ge{sup +} at 150 keV to doses ranging from 1x10{sup 15} to 8x10{sup 15} ions/cm{sup 2}. Boron was subsequently implanted at 3 keV with a dose of 1x10{sup 14} ions/cm{sup 2}. Rapid thermal annealing (RTA) was performed for various time/temperature combinations in nitrogen ambient. Secondary ion mass spectroscopy (SIMS) and transmission electron microscopy (TEM) were used to study boron diffusion and defect evolution, respectively. We have found that after a given annealing, both the defect size and boron diffusivity are independent on the Ge ion dose. Increasing this dose only results in an increase of the defect density. These results are discussed and definitely show that EOR defects are involved in a quasi-conservative Ostwald ...
2002-01-01
Effect of the Ge preamorphization dose on boron diffusion and defect evolution in silicon
International Nuclear Information System (INIS)
In this paper, we study the effect of the Ge"+ preamorphization dose on boron diffusion and on the thermal evolution of end of range (EOR) defects during annealing. Amorphizations were carried out by implanting Ge"+ at 150 keV to doses ranging from 1x10"1"5 to 8x10"1"5 ions/cm"2. Boron was subsequently implanted at 3 keV with a dose of 1x10"1"4 ions/cm"2. Rapid thermal annealing (RTA) was performed for various time/temperature combinations in nitrogen ambient. Secondary ion mass spectroscopy (SIMS) and transmission electron microscopy (TEM) were used to study boron diffusion and defect evolution, respectively. We have found that after a given annealing, both the defect size and boron diffusivity are independent on the Ge ion dose. Increasing this dose only results in an increase of the defect density. These results are discussed and definitely show that EOR defects are involved in a quasi-conservative Ostwald ripening process during annealing. ...
2002-01-01
Development of high power negative ion sources for fusion at JAERI
Energy Technology Data Exchange (ETDEWEB)
Technologies producing high power negative ion beams have been highly developed in these years at JAERI for use in neutral beam injectors for heating the thermonuclear fusion plasmas. At present, it is possible to produce multi-ampere H-/D- ion beams quasi-continuously at energies more than a few hundred keV with a good beam optics of beamlet divergence of a few milli-radian. Based on these technologies, two R and D projects have been initiated; one is to develop a 22A/500keV/10s D- ion source for the neutral beam injector for JT-60U, and the other is to develop a 1A/1MeV/60s H- ion source to demonstrate high current negative ion acceleration up to the energy of 1MeV, the energy required for the neutral beam injector for International Thermonuclear Experimental Reactor (ITER). (author).
1995-10-01
Development of a fine and ultra-fine group cell calculation code SLAROM-UF for fast reactor analyses
International Nuclear Information System (INIS)
A cell calculation code SLAROM-UF has been developed for fast reactor analyses to produce effective cross sections with high accuracy in practical computing time, taking full advantage of fine and ultra-fine group calculation schemes. The fine group calculation covers the whole energy range in a maximum of 900-group structure. The structure is finer above 52.5 keV with a minimum lethargy width of 0.008. The ultra-fine group calculation solves the slowing down equation below 52.5 keV to treat resonance structures directly and precisely including resonance interference effects. Effective cross sections obtained in the two calculations are combined to produce effective cross sections over the entire energy range. Calculation accuracy and improvements from conventional 70-group cell calculation results were investigated through comparisons with reference values obtained with continuous energy Monte Carlo calculations. It was confirmed that ...
2006-08-01
Energy Technology Data Exchange (ETDEWEB)
A C{sub 60} {sup +} primary ion source has been coupled to an ion microscope secondary ion mass spectrometry (SIMS) instrument to examine sputtering of silicon with an emphasis on possible application of C{sub 60} {sup +} depth profiling for high depth resolution SIMS analysis of silicon semiconductor materials. Unexpectedly, C{sub 60} {sup +} SIMS depth profiling of silicon was found to be complicated by the deposition of an amorphous carbon layer which buries the silicon substrate. Sputtering of the silicon was observed only at the highest accessible beam energies (14.5 keV impact) or by using oxygen backfilling. C{sub 60} {sup +} SIMS depth profiling of As delta-doped test samples at 14.5 keV demonstrated a substantial (factor of 5) degradation in depth resolution compared to Cs{sup +} SIMS depth profiling. This degradation is thought to result from the formation of an unusual platelet-like grain structure on the SIMS crater bottoms. Other ...
2006-07-30
Deposition of Cu film on SiO_2 using a partially ionized beam
International Nuclear Information System (INIS)
Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO_2 substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio I(111)/I(200) reaches its maximum value indicating a strong left-angle 111 right-angle texture, while the impurity concentration and resisitivity are minimum. The correlation between the structural, compositional and electrical properties ...
1990-01-01
Deposition of Cu film on SiO sub 2 using a partially ionized beam
Energy Technology Data Exchange (ETDEWEB)
Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO{sub 2} substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio {ital I}(111)/{ital I}(200) reaches its maximum value indicating a strong {l angle}111{r angle} texture, while the impurity concentration and resisitivity are minimum. The correlation between the structural, compositional and ...
1990-05-01
Deposition of Cu film on SiO sub 2 using a partially ionized beam
Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO{sub 2} substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio {ital I}(111)/{ital I}(200) reaches its maximum value indicating a strong {l angle}111{r angle} texture, while the impurity concentration and resisitivity are minimum. The correlation between the structural, compositional and ...
1990-05-01
Corrosion behaviour of molybdenum-implanted stainless steel
Energy Technology Data Exchange (ETDEWEB)
A low-molybdenum austenitic stainless steel (UNS S30100) has been surface implanted with molybdenum ions, using various doses of 50 keV and 140 keV ions at room temperature. It is found that in aqueous sulphate/chloride solutions similar to the constitution of sea-waters the implantation does not affect the potentiostatically-determined critical pitting potential, but does change the density and morphology of corrosion pits. Pitting initiation after the addition of chloride at a fixed potential indicates little change in the time for measurable current increase, but the rate of increase of the current is much lower for implanted material. Detailed examination using optical microscopy, scanning electron microscopy, transmission electron microscopy and selected area diffraction suggests that the pits produced in implanted material are hemispherical with smooth covers of unattacked alloy. The use of half-implanted samples demonstrates that ...
1990-01-01
Corrosion behaviour of molybdenum-implanted stainless steel
International Nuclear Information System (INIS)
A low-molybdenum austenitic stainless steel (UNS S30100) has been surface implanted with molybdenum ions, using various doses of 50 keV and 140 keV ions at room temperature. It is found that in aqueous sulphate/chloride solutions similar to the constitution of sea-waters the implantation does not affect the potentiostatically-determined critical pitting potential, but does change the density and morphology of corrosion pits. Pitting initiation after the addition of chloride at a fixed potential indicates little change in the time for measurable current increase, but the rate of increase of the current is much lower for implanted material. Detailed examination using optical microscopy, scanning electron microscopy, transmission electron microscopy and selected area diffraction suggests that the pits produced in implanted material are hemispherical with smooth covers of unattacked alloy. The use of half-implanted samples demonstrates that ...
1989-09-01
Energy Technology Data Exchange (ETDEWEB)
Two measurement methods to determine the rate of neutral free radical production by the photo-deionization of negative ion beams (PDINIB) are introduced. These methods, namely, photoelectron-current measurement by low-frequency electro-modulation probe (PMMP) and measurement of decrease in the negative-ion beam current (DNIC) were employed to evaluate the production rate in a trial surface-processing apparatus developed in the author's laboratory utilizing a steady-flux refined beam of neutral free radicals (RBNR) produced by the PDINIB procedure. A {sup 63}Cu{sup -} negative ion beam of kinetic energy E{sub i} varied up to 15 keV was irradiated with a 514.5 nm visible light beam from a 25 W CW Ar{sup +} ion laser. The detection limit of the production rate by the PMMP setup was as high as 6 x 10{sup 9} s{sup -1} under the condition that E{sub i}=15 keV, the negative-ion beam current I{sub i}=4 {mu}A and the laser power P=6 W. The DNIC ...
2003-05-01
Comparison of LaBr_3:Ce and NaI(Tl) Scintillators for Radio-Isotope Identification Devices
International Nuclear Information System (INIS)
Lanthanum halide (LaBr_3:Ce) scintillators offer significantly better resolution (< 3% at 662 keV) relative to NaI(Tl) and have recently become commercially available in sizes large enough for the handheld, Radio-Isotope Identification Device (RIID) market. Drawbacks to lanthanum halide detectors, however, include internal radioactivity contributing to spectral counts, and a low-energy response which can cause detector resolution to be worse than that of NaI(Tl) below 100 keV. To study the potential of this new material for RIIDs we performed a series of measurements comparing a 1.5 x 1.5-inch LaBr_3:Ce detector with an Exploranium GR-135 RIID, which contains a 1.5 x 2.2-inch NaI(Tl) detector. Measurements were taken for short timeframes, as typifies RIID usage. Measurements included examples of naturally occurring radioactive material (NORM), typically found in cargo, and special nuclear materials. Some measurements were non-contact, ...
2005-10-23
International Nuclear Information System (INIS)
CEA-Valduc produces some radioactive waste (mainly alpha emitters). Legislation requires producers to sort their waste by activity and type of isotopes, and to package them in order to forward them to the appropriate reprocessing or storage facility. Our lab LMDE (laboratory for measurements on nuclear wastes and valuation) is in charge of the characterization of the majority of waste produced by CEA-Valduc. Among non-destructive methods to characterize a radioactive object, gamma-spectroscopy is one of the most efficient. We present to this conference the method we use to characterize nuclear waste and the system we developed to characterize our germanium detectors. The goal of this system is to obtain reliable numerical models of our detectors and calculate their efficiency curves. Measurements are necessary to checks models and improve them. These measurements are made on a bench using pinpoint sources ("1"3"3Ba, "1"5"2Eu) from 60 keV to 1500 ...
2009-06-07
Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument designed to measure polarization from astrophysical objects in the 30-100 keV range, under development by an international collaboration with members from United States, Japan, Sweden and France. To examine PoGO's capability, a beam test of a simplified prototype detector array was conducted at the Argonne National Laboratory Advanced Photon Source. The detector array consisted of seven plastic scintillators, and was irradiated by polarized photon beams at 60, 73, and 83 keV. The data showed a clear polarization signal, with a measured modulation factor of $0.42 \\pm 0.01$. This was successfully reproduced at the 10% level by the computer simulation package Geant4 after modifications to its implementation of ...
2005-01-01
Absolute differential cross sections for the scattering of kilo-electron-volt O atoms
International Nuclear Information System (INIS)
This paper reports measurements of absolute differential cross sections for the direct scattering of oxygen atoms by He, Ne, Ar, Kr, Xe, H_2, N_2, O_2, CO, CO_2, H_2O, SO_2, NH_3, CH_4, CF_4, and SF_6 targets. The measured cross sections include contributions from all elastic and inelastic processes that result in a fast neutral oxygen atom product. Cross sections are presented for 0.5- and 1.5-keV projectile energies over the laboratory angular range 0.2 degree endash 5 degree. When compared in the center-of-mass reference frame, these cross sections exhibit a high degree of similarity in both amplitude and angular dependence. The cross sections for N_2, CO, CO_2, and H_2O are inverted using a partial-wave analysis to yield empirical interaction potentials, which can then be used to extrapolate the measurements down to lower energies. Using these potentials, cross sections are evaluated at 0.1 keV. copyright 1996 The American Physical Society.
A Remarkable Low-Mass X-ray Binary within 0.1 pc of the Galactic Center
Recent X-ray and radio observations have identified a transient low-mass X-ray binary (LMXB) located only 0.1 pc in projection from the Galactic center, CXOGC J174540.0-290031. In this paper, we report the detailed analysis of X-ray and infrared observations of the transient and its surroundings. Chandra bservations detect the source at a flux of F_X = 2e-12 erg cm^-2 s^-1 (2-8 keV). After accounting for absorption both in the interstellar medium and in material local to the source, the implied luminosity of the source is only L_X = 4e34 erg/s (2-8 keV; D=8 kpc). However, the diffuse X-ray emission near the source also brightened by a factor of 2. The enhanced diffuse X-ray emission lies on top of a known ridge of dust and ionized gas that is visible infrared images. We interpret the X-ray emission as scattered flux from the outburst, and determine that the peak luminosity of CXOGC J174540.0-290031 was >2e36 erg/s. We suggest that the ...
2005-01-01
International Nuclear Information System (INIS)
These experiments were performed on the Isocele separator, on-line with the Orsay synchrocyclotron; thulium isotopes were produced by bombarding natural erbium targets with 150nA beam of 157MeV protons. Two Ge(Li) detectors, with resolution of 2.3 and 2.5keV at 1332keV used for #gamma#-ray measurements; conversion electron spectra were measured using a Si(Li) detector. #gamma# spectra, #gamma#-#gamma# coincidence and conversion electron measurements were sufficient to build the flow energy level schemes of the transitional "1"5"8Er and "1"5"6Er nuclei. On both nuclei several quasi rotational bands have been identified. These results are compared with other even erbium isotopes and with the neighboring N=88 and 90 isotones. Comparisons with predictions issued from some classical models are also performed: "1"5"8Er appears as a deformed nucleus very similar to "1"6"0Er and "1"6"2Er; on the other hand "1"5"6Er seems to be a soft vibrational ...
1976-01-01
Zinc determination in medicinal powders by radionuclide X-ray fluorescence analysis
International Nuclear Information System (INIS)
X-ray fluorescence analysis was used to determine the zinc content of the ''Perilacin'' powder and the ZnO content of the ''Epiderman-pix'' powder. The characteristic Ksub(#alpha#) line of zinc was excited using a "1"4"7Pm/Mo source (10"7 s"-"1) and the molybdenum Ksub(#alpha#) line (17.47 keV). 4 to 5% Zn and 45 to 49% ZnO were determined with a NaI(Tl) scintillation detector. The radiation intensity was found to decrease with particle size. (M.K.).
1977-01-01
Study of penetration depth for V"+ with low energy implanted in peanut seeds
International Nuclear Information System (INIS)
The penetration depth and concentration distribution for vanadium ions with low energy implanted into the dry peanut seeds is determined by scanning electron microscope and X-ray energy dispersion spectrometer. The results show that the depth-concentration distribution is a Gaussian distribution with a long tail and the maximum penetration depth is about 13.6 #mu#m for V"+ with 200 keV in cotyledon of the peanut. The experimental result of the implanted V"+ range in the peanut seeds is compared with the calculating value of the TRIM95
2002-11-01
Studies of Plasma Confinement in GOL-3 Multi-mirror Trap
International Nuclear Information System (INIS)
Recent results of the experiments at GOL-3 facility are presented. Plasma with a density of 1014...1016 cm-3 is confined in a 12-meter-long solenoid, which comprises 55 corrugation cells with mirror ratio Bmax/B min=4.8/3.2 T. The plasma is heated up to 2...4 keV temperature by a high power relativistic electron beam (?1 MeV, ? 330 kA, ?8?s, ?120 kJ) injected through one of the ends. Mechanism of experimentally observed fast ion heating, issued of plasma stability and confinement are discussed.
2006-01-01
Solid-state ozone synthesis by energetic ions
International Nuclear Information System (INIS)
We have synthesized ozone by irradiating thin solid films of oxygen and oxygen-water mixtures with 100 keV protons, motivated by recent reports of condensed O_3 on icy satellites in the outer Solar system. We measured the depth of the Hartley absorption band in the ultraviolet by reflectance spectroscopy and used it to quantify the column density of ozone. We analyzed the results using a three-component (O, O_2 and O_3) model that successfully explains the fluence dependence of ozone production.
1999-08-02
Possibility of internal transport barrier formation and electric field bifurcation in LHD plasma
Energy Technology Data Exchange (ETDEWEB)
Theoretical analysis of the electric field bifurcation is made for the LHD plasma. For given shapes of plasma profiles, a region of bifurcation is obtained in a space of the plasma parameters. In this region of plasma parameters, the electric field domain interface is predicted to appear in the plasma column. The reduction of turbulent transport is expected to occur in the vicinity of the interface, inducing a internal transport barrier. Within this simple model, the plasma with internal barriers is predicted to be realized for the parameters of T{sub e}(0) {approx} 2 keV and n(0) {approx_equal} 10{sup 18} m{sup -3}. (author)
1999-05-01
Photon-induced K-shell X-ray intensity ratio for elements with 74#<=#Z#<=#92
International Nuclear Information System (INIS)
The K-shell X-ray intensity ratios for W, Au, Tl, Pb, Bi, Th and U were measured at a photon incident energy of 121.9 keV from "5"7Co radionuclide. A comparison between the experimental results and the theoretically calculated values shows that the experimental results are, in general, higher than the theoretical values. The measured intensities are regarded to be reported for the first time. (author) 9 refs.; 1 tab.
1989-01-01
Observation of a surface peak in low energy implant depth profiles in silicon
Energy Technology Data Exchange (ETDEWEB)
In situ Auger sputter depth profiles of saturation implants of 3 keV N/sub 2//sup +/ in silicon at room temperature exhibit a sharp peak in the nitrogen concentration in the outermost layers, followed by a monotonic decrease. No broad plateau was observed. The energy of the Auger line corresponding to the Si(2p) core electron excitation, monitored throughout the profiling, exhibits a chemical shift of up to 7 eV at the surface peak concentration. Inert gas ion post-bombardment of unsaturated implants significantly modifies the profile, and supports the suggestion that the surface peak arises through radiation enhanced diffusion of implanted atoms.
1984-03-01
International Nuclear Information System (INIS)
Energy level schemes are derived from gamma spectroscopy of several medium-mass deformed nuclei by studying the decay or proton and #alpha# nuclear spectroscopic data. Some new isomeric studies are established among which is the 31 y "1"7"8Hf isomeric state for which Isup(#pi#), K was determined to be 16"+, 16. A four quasi-particle configuration was assigned to this state at 2447.5 +- 2.5 KeV. Atomic masses have been calculated from various measurements and, on the basis of mass formulae extrapolated to neighboring mass regions.
Nondestructive analysis for "2"3"2U and decay progeny in animal tissues
International Nuclear Information System (INIS)
Direct determination of "2"3"2U and its decay products in animal tissues appears to be feasible using an intrinsic Ge(Li) diode detector (for energies of 5-100 keV) and a NaI(Tl) anticoincidence-shielded Ge(Li) diode for higher-energy gamma photons. The detection sensitivity for "2"3"2U and "2"2"8Th is 0.03 and 0.01 nCi, respectively, using a 300-min counting time.
1977-05-01
Neutron monitoring on cold fusion experiments
International Nuclear Information System (INIS)
A helium-3 proportional detector was equipped with the experiment of Liaw-type electrolytic cell contained eutectic LiCl-KCl molten salt saturated by LiD electrolytic to collect the informations of the rate and the energy distribution of possible neutron produced during the electrolysis processes. For long time monitoring, the significant reproducible neutron bursts appeared at several runs of cells during electrolytic processing. The neutron counting rate increased about a factor of two above the level of the background measurement. The pulse height signals were verified of neutron energy ranging from thermal up to 350 keV. (author).
1992-10-01
Neutron Resonance Parameters and Covariance Matrix of 239Pu
Energy Technology Data Exchange (ETDEWEB)
In order to obtain the resonance parameters in a single energy range and the corresponding covariance matrix, a reevaluation of 239Pu was performed with the code SAMMY. The most recent experimental data were analyzed or reanalyzed in the energy range thermal to 2.5 keV. The normalization of the fission cross section data was reconsidered by taking into account the most recent measurements of Weston et al. and Wagemans et al. A full resonance parameter covariance matrix was generated. The method used to obtain realistic uncertainties on the average cross section calculated by SAMMY or other processing codes was examined.
2008-08-01
Energy Technology Data Exchange (ETDEWEB)
Q/sub ..beta..-values are determined for 18 nuclei (Zr-, Nb-, Mo-, Tc-, Ru- and Rh-nuclides) with mass numbers 101 less than or equal toA less than or equal to106 and A=109 from measurements of beta decay energies which were carried out at the LOHENGRIN mass separator at the Institut Laue-Langevin in Grenoble (France). The given Q/sub ..beta..-values between 2 and 8 MeV show errors of about 1.5% (with the exception of /sup 103/Zr and /sup 105/Nb resp. and /sup 103/Tc for which larger errors result due to statistical resp. systematic reasons): /sup 101/Zr 5500+-70, /sup 101/Nb 4580+-45, /sup 102/Zr 4670+-40, /sup 102/Nb 7230+-70, /sup 103/Zr 6790+-240, /sup 103/ 5740+-70, /sup 103/Mo 3575+-80, /sup 103/Tc 2585+-70, /sup 104/Nb 8250+-130, /sup 104/Mo 2180+-40, /sup 104/Tc 5520+-100, /sup 105/Nb 6570+-150, /sup 105/Mo 4885+-80, /sup 105/Tc 3750+-60, /sup 106/Mo 3515+-45, /sup 106/Tc 6540+-70, /sup 109/Ru 4150+-80, /sup 109/Rh 2550+-50 (all values in keV). For the ...
1986-10-31
International Nuclear Information System (INIS)
Q_#beta#-values are determined for 18 nuclei (Zr-, Nb-, Mo-, Tc-, Ru- and Rh-nuclides) with mass numbers 101 #<=# A #<=# 106 and A=109 from measurements of beta decay energies which were carried out at the LOHENGRIN mass separator at the Institut Laue-Langevin in Grenoble (France). The given Q_#beta#-values between 2 and 8 MeV show errors of about 1.5% (with the exception of "1"0"3Zr and "1"0"5Nb resp. and "1"0"3Tc for which larger errors result due to statistical resp. systematic reasons): "1"0"1Zr 5500#+-#70, "1"0"1Nb 4580#+-#45, "1"0"2Zr 4670#+-#40, "1"0"2Nb 7230#+-#70, "1"0"3Zr 6790#+-#240, "1"0"3 5740#+-#70, "1"0"3Mo 3575#+-#80, "1"0"3Tc 2585#+-#70, "1"0"4Nb 8250#+-#130, "1"0"4Mo 2180#+-#40, "1"0"4Tc 5520#+-#100, "1"0"5Nb 6570#+-#150, "1"0"5Mo 4885#+-#80, "1"0"5Tc 3750#+-#60, "1"0"6Mo 3515#+-#45, "1"0"6Tc 6540#+-#70, "1"0"9Ru 4150#+-#80, "1"0"9Rh 2550#+-#50 (all values in keV). For the measurement of beta-gamma coincidences a #DELTA#E/E-plastic ...
LUCIFER, a potentially background-free approach to the search for neutrinoless double beta decay
British Library Electronic Table of Contents (United Kingdom)
LUCIFER (Low-background Underground Cryogenic Installation For Elusive Rates) is a new project for the study of neutrinoless Double Beta Decay, based on the technology of scintillating bolometers. These devices promise a very efficient rejection of the alpha background, opening the way to a virtual background-free experiment if candidates with a transition energy higher than 2615 keV are investigated. The baseline candidate for LUCIFER is 82Se. This isotope will be embedded in ZnSe crystals grown with enriched selenium and operated as scintillating bolometers in a low-radioactivity underground dilution refrigerator. In this paper, the LUCIFER concept will be introduced. The sensitivity and the very promising prospects related to this project will be discussed.
2011-01-01
International Nuclear Information System (INIS)
The additional error in measurement of the thickness of Kh18N10T steel for possible changes in composition with an energy of the photons of ionizing radiation of 10-80 keV was evaluated. The desirability of use of a type REIS-I x-ray emitter in measurement of the thickness of steel up to 1 mm is shown. The instrument provides measurement of the thickness of steel in the 0.1-1.0 mm range with a reproducibility of the results with an error not exceeding 0.5-1.0%. The measurement error with corrugations characteristic of bellows does not exceed 5%.
High current implantation of negative copper ions into silica glasses
Energy Technology Data Exchange (ETDEWEB)
High-current implantation of Cu{sup {minus}} ions into silica glasses has been demonstrated using mA-class negative ion beams at 60 keV. Negative ion implantation has an advantage to alleviate specimen charging for insulating substrates and has attained high dose rates, up to 260 {micro}A/cm{sup 2}. Spherical Cu colloids form in the silica glasses without additional thermal annealing. Optical absorption and reflection of the implanted specimens vary with the current density, even at a fixed dose level. A beam-induced surface plasma may affect the high current implantation.
1997-12-01
Experimental study of beam optics and energy recovery for high-energy electron cooling device
International Nuclear Information System (INIS)
The feasibility of a high-energy electron cooling device has been studied through tests on a prototype of the electron device. The apparatus consists of a pulsed ((20-60) keV, 2#mu#s) electron gun, a drift region 1 m long and of a depressed collector for recovering the electron energy. Tests on beam optics and energy recovery have been performed, a high-energy recovery efficiency has been attained. Experimental results are discussed in this paper.
Energy Technology Data Exchange (ETDEWEB)
An electrostatic beam steering mechanism (ESM) has been designed and tested to deflect negative ion beams consisting of multi-beamlets. A steering angle of 10 mrad was obtained within the deviation of less than 1 mrad by biasing two electrodes at 0.5 kV and -0.75 kV for 120 keV H{sup -} ion beam. The current flowing to the positive electrode was no more than 10% of the beam current at a pressure of 2.8x10{sup -5} Torr. (author)
1998-11-01
Delayed neutron energy spectra following fast fission of "2"3"8U
International Nuclear Information System (INIS)
Delayed neutron energy spectra have been measured for six delay-time intervals following the fast fission of "2"3"8U nuclei. The delay-time intervals span the range 0.17 to 10.2 seconds following initial fission while the measured spectra span neutron energies from 10 keV to 4 MeV. The experiment was performed utilizing the UMass/Lowell 5.5 MV Van de Graff accelerator to produce fast neutrons for inducing fission in a "2"3"8U lined fission chamber. The fission fragments were flushed via a helium jet stream to a well-shielded counting room where they were deposited onto a moving tape (magnetic audio tape) and transferred to a beta-neutron time-of-flight spectrometer. By adjusting the tape speed, composite delayed neutron time-of-flight spectra were measured for several different delay-time intervals. These measurements involved beta-neutron coincidences with "6Li-loaded glass scintillators for neutron energies from 10 keV to 450 ...
CMOS/SOI hardening at 100 MRAD (SiO_2)
International Nuclear Information System (INIS)
Hardened CMOS/SOI 29101 microprocessor, elementary cells and transistor shave been irradiated at levels between 10 Mrad(SiO_2) and 1 Grad(SiO_2) ("6"0Co and 10 keV x-rays). SIMOX buried oxide behavior in the range of 100 Mrad(SiO_2) and a channel-stopped MOS/SOI structure avoiding lateral leakage current are presented. These two items indicate the feasibility of a CMOS/SOI technology operating in the hundred Mrad(SiO_2) range.
1990-07-16
Angular scattering in electron capture and loss D/sup -/ beam formation processes
Energy Technology Data Exchange (ETDEWEB)
The development of high energy (> 150 keV) neutral beams for heating and fueling magnetic fusion devices depends on the ability to produce well-collimated negative ion beams. The double capture charge-exchange technique is a known, scalable method. In order to maximize the overall efficiency of the process and to achieve the desired beam characteristics, it is necessary to examine the optical qualities of the beams as well as the total efficiency of beam production. A combined modeling and experimental study of the angular scattering effects in negative ion formation and loss processes has therefore been undertaken.
1980-01-01
An Apparent Hard X-ray Decline of CH Cygni
CH Cygni is a symbiotic star consisting of an M giant and an accreting white dwarf, which is known to be a highly variable X-ray source with a complex, two-component, spectra. Here we report on two Suzaku observations of CH Cyg, taken in 2006 January and May, during which the system was seen to be in a soft X-ray bright, hard X-ray faint state. Based on the extraordinary strength of the 6.4 keV fluorescent Fe K-alpha line, we show that the hard X-rays observed with Suzaku are dominated by scattering.
2006-01-01
Alignment accuracy of focused ion beam implantation
Energy Technology Data Exchange (ETDEWEB)
The theoretical alignment limit for focused ion beam (FIB) implantation was deduced from the calculated resolution for the detection of an alignment mark. The alignment resolution varies with the signal to noise ratio and there is an optimum current which gives the best resolution. The alignment resolution epsilon/sub sigma/ is approximately 0.006 ..mu..m for a 160 keV Si/sup ++/ beam from our FIB implanter. The measured alignment error is approximately 0.06 ..mu..m and the main reason of this discrepancy is vibration. The ultimate limit on the alignment error can be reached through improvements in the implanter system.
1987-06-01
"4"8Ca(d,n)"4"9Sc reaction at 79 MeV
International Nuclear Information System (INIS)
We measured differential cross sections and vector analyzing powers for the "4"8Ca(d,n)"4"9Sc reaction at 79 MeV. An overall energy resolution of about 325 keV was achieved, and data were extracted for states up to 3.4 MeV of excitation. Both distorted-wave Born approximation and Johnson-Soper adiabatic approximation calculations were performed; in general, the Johnson-Soper adiabatic approximation calculations provide a better description of the data, and yield reasonable spectroscopic factors.
Energy Technology Data Exchange (ETDEWEB)
High-resolution neutron capture cross section measurements of 55Mn were recently performed at GELINA by Schillebeeckx et al. (2005) and at ORELA by Guber et al. (2007). The analysis of the experimental data was performed with the computer code SAMMY using the Bayesian approach in the resonance parameters representation of the cross sections. The neutron transmission data taken in 1988 by Harvey et al. (2007) and not analyzed before were added to the SAMMY experimental data base. More than 95% of the s-wave resonances and more than 85% of the p-wave resonances were identified in the energy range up to 125 keV, leading to the neutron strength functions S0 = (3.90 0.78) x 10-4 and S1 = (0.45 0.08) x 10-4. About 25% of the d-wave resonances were identified with a possible strength function of S2 = 1.0 x 10-4. The capture cross section calculated at 0.0253 eV is 13.27 b, and the capture resonance integral is 13.52 0.30 b. In the energy range 15 to 120 ...
2008-05-01
Energy Technology Data Exchange (ETDEWEB)
The use of nitrogen ion implantation to increase the surface hardness of structural steels is well documented. Traditionally this involves the use of high energy nitrogen ion beams (approximately 100 keV), with a relatively low beam current density because high energy beams are necessary to produce the required penetration into the material to achieve a significant depth of hardened material. Hardening needs to occur in a region whose size is comparable with the scale of the deformation associated with the tribocontact. 100 keV nitrogen ions typically penetrate into steels only about 0.1 {mu}m and the range of possible tribological applications is thus restricted by this shallow treatment depth. In plasma nitriding processes the nitrogen ions approach the substrate with much lower energies but the ion currents are sufficiently high to cause considerable substrate heating. In this study an ion beam process has been used which more closely ...
1996-09-01
International Nuclear Information System (INIS)
In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the "1"3"7Cs-source with 10.4 GBq and "6"0Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form "1"3"7 Cs 1173.23 and 1332.51 keV"6"0 Co sources, and 14 peaks of "1"3"4Cs and "1"5"4Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show that the detection efficiency of gamma scanning system for 1 MeV ...
2003-10-01
Energy Technology Data Exchange (ETDEWEB)
(methine-{sup 3}H)1,1-Di-(4-chlorophenyl)-2,2,2-trichloroethane ((methine-{sup 3}H)DDT) and its di-(4-nitrophenyl) analog, both of high purity with a moderately high specific activity were prepared. Chloro-benzene was condensed with (1-{sup 3}H)1-(4-chlorophenyl)-2,2,2-trichloro-ethanol, which has been synthesized by sodium boro({sup 3}H)hydride reduction of 4-chlorophenyl trichloromethyl ketone. The purified ({sup 3}H)DDT had a specific activity of 0.77 Ci/mmol (28.49 GBq/mmol). (methine-{sup 3}H)1,1-Diphenyl-2,2,2-trichloroethane was similarly synthesized and was nitrated to give (methine-{sup 3}H)1,1-di-(4-nitrophenyl)-2,2,2-trichloro-ethane of 1.63 Ci/mmol (60.31 GBq/mmol). Dehydrochlorination with housefly enzyme (glutathione-dependent DDT dehydrochlorinase) showed a remarkable isotope effect. For DDT, the observed tritium isotope effect on V{sub max}/K{sub m} was 11.51{plus minus}0.52. For the nitro-analog, the value was 11.3{plus minus}1.2. We measured ...
1989-08-01
Swelling behavior of a simple ferritic alloy
International Nuclear Information System (INIS)
The swelling behavior which results from simulated fusion environment irradiation of Fe-10% Cr has been characterized with transmission electron microscopy. Specimens were bombarded at 850 K with: a ''triple-beam'' of He"+, D_2"+, and 4 MeV Fe"+"+ ions to 0.3, 1, 3, 10, 30, and 100 dpa (displacement per atom); a ''dual-beam'' of He"+ and 4 MeV Fe"+"+ ions to 30 and 100 dpa; and a ''single-beam'' of 4 MeV Fe"+"+ ions to 30 dpa. The helium and hydrogen injection rates were approx. =10 appm He/dpa and approx. =40 appm D/dpa. Cavities were observed for damage levels of 3 dpa and greater. The swelling was <0.1% for damage levels <30 dpa, but at 100 dpa, there was an increase in the swelling to 2.5% for the ''triple-beam'' irradiation and 1.2% for the ''dual-beam'' irradiation. The swelling rates between 30 and 100 dpa correlate well with calculated values assuming a steady-state swelling-rate regime has been reached. Calculations show the rapid cavity growth associated with this ...
Solid state NMR, basic theory and recent progress for quadrupole nuclei with half-integer spin
International Nuclear Information System (INIS)
This review describes the basic theory and some recently developed techniques for the study of quadrupole nuclei with half integer spins in powder materials. The latter is connected to the introduction of the double rotation (DOR) by A. Samoson et al. (1) and to the introduction of the multiple quantum magic-angle spinning (MQ MAS) technique by L. Frydman et. al. (2). For integer spins, especially the solid-state deuterium magnetic resonance, we refer to the review of G.L. Hoatson and R.L. Vold: ''"2H-NMR Spectroscopy of Solids and Liquid Crystals'' (3). For single crystals we refer to O. Kanert and M. Mehring: ''Static quadrupole effects in disordered cubic solids''(4) and we would like also to mention the ''classic'' review of M.H. Cohen and F. Reif: ''Quadrupole effects in NMR studies of solids'' (5). Some more recent reviews in the field under study are D. Freude and J. Haase ''Quadrupole effects in solid-state NMR'' (6). Ch. Jager: ''Satellite Transition ...
1998-12-01
Simplified fusion power plant costing. A general prognosis and call for `new think`
Energy Technology Data Exchange (ETDEWEB)
A top-level costing model is developed and used to project the cost of electricity (COE) (in mills per kilo watt-hour) expected from conceptual fusion power plants. Application is restricted to magnetic fusion energy (MFE) concepts. These costs are estimated parametrically in terms of the mass of the fusion-power-core (FPC) heater, the power required to sustain a reacting deuterium-tritium plasma, the heat transport/transfer system that delivers the fusion power to the balance of plant (BOP), and the BOP needed to convert the fusion heat to electrical power. Although the highly integrated (simplified) cost-estimating relationships (CERs) used to express COE in terms of FPC mass power density (MPD) [in kilowatt(electric) per tonne] and the engineering gain Q{sub E} (inverse of fraction of gross electric power recirculated to the fusion power plant) apply primarily to MFE approaches to fusion power, the costing gauge thus results is generally independent of ...
1995-03-01
Jet flow analysis of liquid poison injection in a CANDU reactor using source term
Energy Technology Data Exchange (ETDEWEB)
For the performance analysis of Canadian deuterium uranium (CANDU) reactor shutdown system number 2 (SDS2), a computational fluid dynamics model of poison jet flow has been developed to estimate the flow field and poison concentration formed inside the CANDU reactor calandria. As the ratio of calandria shell radius over injection nozzle hole diameter is so large (1055), it is impractical to develop a full-size model encompassing the whole calandria shell. In order to reduce the model to a manageable size, a quarter of one-pitch length segment of the shell was modeled using symmetric nature of the jet; and the injected jet was treated as a source term to avoid the modeling difficulty caused by the big difference of the hole sizes. For the analysis of an actual CANDU-6 SDS2 poison injection, the grid structure was determined based on the results of two-dimensional real- and source-jet simulations. The maximum injection velocity of the liquid poison is 27.8 m/s and ...
2001-01-01
Energy Technology Data Exchange (ETDEWEB)
A comparative test in mice for pulmonary toxicity between butylated hydroxytoluene (2,6-di-tert.-butyl-4-methylphenol, BHT) and 2,6-di-tert.-butyl-4-(alpha, alpha, alpha-2H3)methylphenol (BHT-d3) showed a significantly lower toxic potency of the latter. The rate of in vitro BHT metabolism to 2,6-di-tert.-butyl-4-methylene-2,5-cyclohexadienone (BHT-QM) was slowed by deuterating BHT in the 4-methyl group. On the other hand, the rate of in vitro metabolism to 2,6-di-tert.-butyl-4-hydroxy-4-methyl-2,5-cyclohexadienone (BHT-OH) was increased with the deuteration. A similar isotope effect of the deuterium substitution on the in vivo metabolic rates of BHT was observed. These observations support the concept that the lung damage caused by BHT is mediated by BHT-QM. The pulmonary toxicity of 2-tert.-butyl-4-ethylphenol (4-EP) and their deuterated analogs was also compared. 2-tert.-Butyl-4-(1,1-2H2)ethylphenol (4-EP-d2) showed a significantly lower toxic potency than 4-EP, ...
1983-06-30
High-precision Penning-Trap measurements of light-ion masses
International Nuclear Information System (INIS)
The UW-Penning Trap Mass Spectrometer (PTMs) is ideally suited for high precision measurements of atomic masses throughout the periodic table upon using highly-stripped ions. However, at the present time, this device has been applied extensively to the light elements ("1H, "2H, "3H, "3He, "4He, "1"2C, "1"3C, "1"4N, "1"6O) due to their fundamental importance. Atomic masses follow immediately from a comparison with some multiply-charged carbon ion, after correcting for the lost electrons and their corresponding binding energies. For instance, the most recent C"5"+/C"6"+ comparison yielded a discrepancy of -0.30(33) ppb, limited only by the magnetic field instability for a 40-h run. The initial emphasis on hydrogen has now produced a 1-ppb value for the proton's atomic mass and similar work with deuterium has yielded a 2.5-ppb value for the neutron's atomic mass. However, the most significant result is the "3H-"3He mass difference = 18,590.1(17) eV which is determined ...
1993-04-12
Evaluation of tritium diffusion through the Neutral Beam Injector calorimeter panel
Energy Technology Data Exchange (ETDEWEB)
The Neutral Beam Test Facility (NBTF) to be realized in Padoa will test the Neutral Beam Injection (NBI), one of the Heating and Current Drive Systems foreseen for ITER. The NBI is based on the acceleration of hydrogen or deuterium negative ions up to 1 MeV. This work has been aimed at assessing the tritium release from the NBTF in order to provide data for the safety analysis. In particular, the diffusion of the tritium through the neutral beam target material (the CuCrZr alloy calorimeter panels) has been assessed by using literature data of the diffusion coefficient. The tritium generated inside the calorimeter panels moves into both the vacuum and water side: the tritium diffusion flux has been evaluated during the beam-on (200 deg. C) and the beam-off (20 deg. C) phases of the NBTF experiments consisting of an interim campaign and a final test. The penetration depth of the tritium through the 2 mm thick CuCrZr alloy material has been also evaluated by using a ...
2009-06-15
Evaluation of tritium diffusion through the Neutral Beam Injector calorimeter panel
International Nuclear Information System (INIS)
The Neutral Beam Test Facility (NBTF) to be realized in Padoa will test the Neutral Beam Injection (NBI), one of the Heating and Current Drive Systems foreseen for ITER. The NBI is based on the acceleration of hydrogen or deuterium negative ions up to 1 MeV. This work has been aimed at assessing the tritium release from the NBTF in order to provide data for the safety analysis. In particular, the diffusion of the tritium through the neutral beam target material (the CuCrZr alloy calorimeter panels) has been assessed by using literature data of the diffusion coefficient. The tritium generated inside the calorimeter panels moves into both the vacuum and water side: the tritium diffusion flux has been evaluated during the beam-on (200 deg. C) and the beam-off (20 deg. C) phases of the NBTF experiments consisting of an interim campaign and a final test. The penetration depth of the tritium through the 2 mm thick CuCrZr alloy material has been also evaluated by using a ...
2009-06-01
International Nuclear Information System (INIS)
The molar heat capacities of chloroform, dichloromethane, methanol, acetonitrile, acetone, dimethyl sulfoxide, benzene, dimethylformamide, toluene, and cyclohexane, as well as their deuterated isotopologues, were measured using a multi-channel heat conduction TAM (Thermal Activity Monitor) III microcalorimeter. In addition, the apparent molar heat capacities of some of the associated dilute aqueous solutions (0.0039 i < 0.0210) were also measured. A temperature drop method from (298.15 to 297.15) K at 0.1 MPa was employed. The corresponding heat capacities were determined from the integration of the measured heat flow. The heat capacity results are shown to be in good to very good agreement with the available literature values. In addition, good correlations were obtained for the effect of isotopic substitution on both molar heat capacity and apparent molar heat capacity in aqueous solutions. These correlations should be useful in the prediction of the molar heat capacities or the ...
2008-11-01
APSTNG: Neutron interrogation for detection of nuclear and CW weapons, explosives, and drugs
Energy Technology Data Exchange (ETDEWEB)
A recently developed neutron diagnostic probe system has the potential to satisfy a significant number of van-mobile and fixed- portal requirements for nondestructive verification of sealed munitions and detection of contraband explosives and drugs. The probe is based on a unique associated-particle sealed-tube neutron generator (APSTNG) that interrogates the object of interest with a low-intensity beam of 14-MeV neutrons generated from the deuterium-tritium reaction and that detects the alpha-particle associated with each neutron. Gamma-ray spectra of resulting neutron inelastic scattering and fission reactions identify nuclides associated with all major chemicals in chemical warfare agents, explosives, and drugs, as well as many pollutants and fissile and fertile special nuclear material. Flight times determined from determined from detection times of the gamma-rays and alpha-particles yield a separate tomographic image of each identified nuclide. The APSTNG also ...
1992-07-01
{delta}-excitations and the three-nucleon force
Energy Technology Data Exchange (ETDEWEB)
We study the three-nucleon force in chiral effective field theory with explicit {delta}-resonance degrees of freedom. We show that up to next-to-next-to-leading order, the only contribution to the isospin symmetric three-nucleon force involving the spin-3/2 degrees of freedom is given by the two-pion-exchange diagram with an intermediate delta, frequently called the Fujita-Miyazawa force. We also analyze the leading isospin-breaking corrections due to the delta. For that, we give the first quantitative analysis of the delta quartet mass splittings in chiral effective field theory including the leading electromagnetic corrections. The charge-symmetry breaking three-nucleon force due to an intermediate delta excitation is small, of the order of a few keV.
2008-06-15
X-ray exposure in the teaching of science at junior and senior high schools
Energy Technology Data Exchange (ETDEWEB)
A significant amount of X-rays were detected as a leakage from some of the Crooke`s tubes which were used in the teaching of science at junior and senior high schools in Japan. We measured the leaked dose of X-rays from the Crooke`s tubes with ionizing chambers, film badges and TLDs. The maximum leaked dose at 5cm distance from those tubes was estimated 143mSv/h. The effective energy of leaked X-rays was 19.3keV. The maximum dose of students exposed during the teaching of science were estimated 0.15mSv per experiment, which exceeded the value recommended in the ICRP publication 36. (author)
1995-10-01
VLF wave stimulation by pulsed electron beams injected from the space shuttle
International Nuclear Information System (INIS)
Among the investigations conducted on the space shuttle flight STS 3 March 1982 was an experiment in which a 1-keV, 100-mA electron gun was pulsed at 3.25 and 4.87 kHz. The resultant waves were measured with a broadband plasma wave receiver. At the time of flight the experimental setup was unique in that the electron beam was square wave modulated and that the shuttle offered relatively long times for in situ measurements of the ionospheric plasma response to the VLF pulsing sequences. In addition to electromagnetic response at the pulsing frequencies the waves exhibited various spectral harmonics as well as the unexpected occurrence of satellite lines around those harmonics. Both phenomena occurred with a variety of different characteristics for different pulsing sequences.
Energy Technology Data Exchange (ETDEWEB)
A time-of-flight mass spectrometer has been constructed to measure the energy spectra of particles scattered by 10/sup 0/ with primary energies between 200 eV and 15 keV. The energy resolution ..delta..E/E of the system is between 0.1 and 0.4%. Energy spectra of scattered molecules and their dissociation products are shown for 570 eV H/sub 2//sup +/ and 4430 eV N/sub 2//sup +/ as projectiles. Electron capture into unbound states of the neutral molecule, with perhaps some contribution from mutual scattering within the molecule, appears to explain the observed dissociation product energy spectra peak widths.
1984-03-01
International Nuclear Information System (INIS)
A time-of-flight mass spectrometer has been constructed to measure the energy spectra of particles scattered by 10"0 with primary energies between 200 eV and 15 keV. The energy resolution #DELTA#E/E of the system is between 0.1 and 0.4%. Energy spectra of scattered molecules and their dissociation products are shown for 570 eV H_2"+ and 4430 eV N_2"+ as projectiles. Electron capture into unbound states of the neutral molecule, with perhaps some contribution from mutual scattering within the molecule, appears to explain the observed dissociation product energy spectra peak widths. (orig.).
The {sup 234}U neutron capture cross section measurement at the n TOF facility
Energy Technology Data Exchange (ETDEWEB)
The neutron capture cross-section of {sup 234}U has been measured for energies from thermal up to the keV region in the neutron time-of-flight facility n-TOF, based on a spallation source located at CERN. A 4{pi} BaF{sub 2} array composed of 40 crystals, placed at a distance of 184.9 m from the neutron source, was employed as a total absorption calorimeter (TAC) for detection of the prompt {gamma}-ray cascade from capture events in the sample. This text describes the experimental setup, all necessary steps followed during the data analysis procedure. Results are presented in the form of R-matrix resonance parameters from fits with the SAMMY code and compared to the evaluated data of Endf in the relevant energy region, indicating the good performance of the n-TOF facility and the TAC. (authors)
2008-07-01
The search for decaying Dark Matter
We propose an X-ray mission called Xenia to search for decaying superweakly interacting Dark Matter particles (super-WIMP) with a mass in the keV range. The mission and its observation plan are capable of providing a major break through in our understanding of the nature of Dark Matter (DM). It will confirm, or reject, predictions of a number of particle physics models by increasing the sensitivity of the search for decaying DM by about two orders of magnitude through a wide-field imaging X-ray spectrometer in combination with a dedicated observation program. The proposed mission will provide unique limits on the mixing angle and mass of neutral leptons, right handed partners of neutrinos, which are important Dark Matter candidates. The existence of these particles is strongly motivated by observed neutrino flavor oscillations and the problem of baryon asymmetry of the Universe. In super-WIMP models, the details of the formation of the cosmic web are different from ...
2009-01-01
The influence of target backing on ion-beam electron spectra
International Nuclear Information System (INIS)
Several different aspects of the influence of the target backing on in-beam electron spectra following compound nuclear reactions induced by accelerated ions at tandem energies irradiating backed targets are discussed in detail. This discussion is illustrated by a few typical examples, such as "1"2C"5"+ and "3"1P"1"0"+ beams at 4 MeV/u bombarding Sn(+Be), Sn(+Au), Pb(+C) backed targets. Moreover, the relative influence of electron backscattering, electron Doppler shift and Doppler broadening as well as #delta#-electron emission on the low energy electron spectra (E_e#<=#100 keV) obtained under such conditions are investigated in the frame of the available experimental data. (orig.).
The fraction of substitutional boron in silicon during ion implantation and thermal annealing
Energy Technology Data Exchange (ETDEWEB)
We present results from a kinetic Monte Carlo simulation of boron transient enhanced diffusion (TED) in silicon. Our approach avoids the use of phenomenological fits to experimental data by using a complete and self-consistent set of values for defect and dopant energetics derived mostly from {ital ab initio} calculations. The results predict that, during annealing of 40 keV B-implanted Si at 800{degree}C, there exists a time window during which all the implanted boron atoms are substitutional. At earlier or later times, the interactions between free silicon self-interstitials and boron atoms drive the growth of boron clusters and result in an inactive boron fraction. The results show that the majority of boron TED takes place during the growth period of interstitial clusters and not during their dissolution. {copyright} {ital 1998 American Institute of Physics.}
1998-05-01
The fraction of substitutional boron in silicon during ion implantation and thermal annealing
International Nuclear Information System (INIS)
We present results from a kinetic Monte Carlo simulation of boron transient enhanced diffusion (TED) in silicon. Our approach avoids the use of phenomenological fits to experimental data by using a complete and self-consistent set of values for defect and dopant energetics derived mostly from ab initio calculations. The results predict that, during annealing of 40 keV B-implanted Si at 800 degree C, there exists a time window during which all the implanted boron atoms are substitutional. At earlier or later times, the interactions between free silicon self-interstitials and boron atoms drive the growth of boron clusters and result in an inactive boron fraction. The results show that the majority of boron TED takes place during the growth period of interstitial clusters and not during their dissolution. copyright 1998 American Institute of Physics.
1998-05-01
The effect of ion implantation of Ar on the aqueous corrosion resistance of Zr-4 alloy
International Nuclear Information System (INIS)
The effect of ion implantation on the aqueous corrosion resistance of Zr-4 in deaerated 1N H_2SO_4 was studied with the potentiokinetic technique. The Zr-4 alloy was bombarded with 5x10"1"4-2x10"1"6 Ar/cm"2 of 190 keV. It was found that the passive current density of Zr-4 decreases with increasing implantation dose. Photoelectrochemical results show that the ion implantation of Ar in Zr-4 raises the flatband potential of its passive film. AES was employed to analyze the surface of the passive film of Zr-4. The decrease in passive current density may be attributed to a thickening oxide layer on Zr-4 and a decrease in concentration of oxygen vacancies in its passive film. ((orig.)).
The emission of the plerion G21.5-0.9 appears more extended in X rays than in radio. This is an unexpected result because it would imply that short-lived X-ray electrons may reach distances even larger than radio electrons. Applying an empirical relationship between dust scattering optical depth and photoelectric column density, the measured column density leads to a large optical depth at 1 keV, of about 1. Therefore we investigate the hypothesis that the detected halo be an effect of dust scattering, re-analyzing an Cal/PV XMM-Newton observation of G21.5-0.9 and critically examining it in terms of a dust scattering model. We also present a spectral analysis of a prominent extended feature in the northern sector of the halo.
2003-01-01
Technique for generating atomic negative ion beams of the group IA elements
Energy Technology Data Exchange (ETDEWEB)
A technique has been developed which enables the direct sputter generation of atomic negative ion beams of all members of the Group IA elements (Li, Na, K, Rb and Cs). The method is based on the use of sputter samples formed by pressing mixtures of the carbonates of the Group IA elements and 10% (atomic) Cu, Ag or other metal powders. The following intensities are typical of those observed from carbonate samples subjected to approx. = 3 keV cesium ion bombardment: Li/sup -/: greater than or equal to 0.5 ..mu..A; Na/sup -/: greater than or equal to 0.5 ..mu..A; K/sup -/: greater than or equal to 0.5 ..mu..A; Rb/sup -/: greater than or equal to 0.5 ..mu..A; Cs/sup -/: greater than or equal to 0.2 ..mu..A.
1989-03-15
British Library Electronic Table of Contents (United Kingdom)
Irradiation of EP-823 (16Cr12MoWsiVNbB) ferritic-martensitic steel with 7-MeV Ni++ ions and with 30- and 70-keV He+ ions at a temperature of 500?C was followed by an increase in the microhardness, which was due to both radiation point defects and changes in the phase composition and the dislocation structure of the steel. It was found that the dependence of the largest relative increase in the microhardness on the concentration of radiation-induced point defects in the near-surface region of the steel under irradiation with different ions correlated with an analogous dependence of the surface segregation of silicon and chromium.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The effect of {ital in} {ital situ} photoexcitation during boron ion implantation on subsequent transient enhanced B diffusion in Si has been investigated. Photoexcitation using a mercury arc lamp was performed during B{sup +} implantation at 35 keV for a dose of 5{times}10{sup 14} cm{sup {minus}2} at 177 K. A reduction in the electrical activation dip, i.e., reverse annealing effect, in the temperature range 550--700 {degree}C was observed. Also, the transient enhanced diffusion of B, measured using SIMS following 800 {degree}C, 30 min annealing, was suppressed. Both effects demonstrate that the creation of self-interstitials during the implantation process is significantly reduced. {copyright} {ital 1995} {ital American} {ital Institute} {ital of} {ital Physics}.
1995-10-09
International Nuclear Information System (INIS)
The effect of in situ photoexcitation during boron ion implantation on subsequent transient enhanced B diffusion in Si has been investigated. Photoexcitation using a mercury arc lamp was performed during B"+ implantation at 35 keV for a dose of 5x10"1"4 cm"-"2 at 177 K. A reduction in the electrical activation dip, i.e., reverse annealing effect, in the temperature range 550--700 degree C was observed. Also, the transient enhanced diffusion of B, measured using SIMS following 800 degree C, 30 min annealing, was suppressed. Both effects demonstrate that the creation of self-interstitials during the implantation process is significantly reduced. copyright 1995 American Institute of Physics.
Study of the cyclotron feature in MXB 0656-072
We have monitored a Type II outburst of the Be/X-ray binary MXB 0656-072 in a series of pointed RXTE observations during October through December 2003. The source spectrum shows a cyclotron resonance scattering feature at 32.8 +/- 0.5 keV, corresponding to a magnetic field strength of (3.67 +/- 0.06) x 10^12 G and is stable through the outburst and over the pulsar spin phase. The pulsar, with an average pulse period of 160.4 +/- 0.4 s, shows a spin-up of 0.45 s over the duration of the outburst. From optical data, the source distance is estimated to be 3.9 +/- 0.1 kpc and this is used to estimate the X-ray luminosity and a theoretical prediction of the pulsar spin-up during the outburst.
2006-01-01
International Nuclear Information System (INIS)
Studies on the separation of Ag(I) during the recovery of Pu from analytical waste generated during potentiometric determination of Pu using AgO as oxidant, by precipitation of Pu as ammonium plutonium (III) oxalate have shown that most of the Ag(I) is separated during the reduction of Pu to Pu(III) state by ascorbic acid. A decontamination factor of 54 was obtained. Additional a decontamination factor of 5.8 was obtained during the precipitation of Pu as ammonium plutonium (III) oxalate. The Ag content was determined by gamma spectrometry, using "1"1"1Ag as a tracer (T_1_/_2 7.45 d, #gamma# 342.1 keV) and HPGe as detector. The studies indicate that Ag is preferentially separated almost quantitatively during the recovery of plutonium, when acidity adjustment is done with NaOH instead of NH_3. (author)
2007-02-14
Studies of the low-lying levels in /sup 192/Pt and /sup 192/Os
Energy Technology Data Exchange (ETDEWEB)
The energy level schemes of /sup 192/Os and /sup 192/Pt have been established on the basis of ..gamma..-..gamma.. coincidence studies using a dual parameter data collection system. Ge(Li) detectors were employed to study the gamma spectra produced in the E.C. and ..beta../sup -/ decays of /sup 192/Ir to /sup 192/Os and /sup 192/Pt, respectively. Thirteen new transitions and three new levels at 1146.95, 1237.35 and 1913.76 keV are suggested. Relative intensities from singles measurements, branching ratios, ..cap alpha..(K) and log ft values were calculated and multipolarities, spins and parities deduced. Comparisons are made with predictions of the Interacting Boson Model calculated on the basis of an O(6) to SU(3) transition.
1985-02-01
Studies of the low-lying levels in "1"9"2Pt and "1"9"2Os
International Nuclear Information System (INIS)
The energy level schemes of "1"9"2Os and "1"9"2Pt have been established on the basis of #gamma#-#gamma# coincidence studies using a dual parameter data collection system. Ge(Li) detectors were employed to study the gamma spectra produced in the E.C. and #beta#"- decays of "1"9"2Ir to "1"9"2Os and "1"9"2Pt, respectively. Thirteen new transitions and three new levels at 1,146.95, 1,237.35 and 1,913.76 keV are suggested. Relative intensities from singles measurements, branching ratios, #alpha#(K) and log ft values were calculated and multipolarities, spins and parities deduced. Comparisons are made with predictions of the Interacting Boson Model calculated on the basis of an O(6) to SU(3) transition. (orig.).
1985-01-01
Spatial distribution of IGC-30 Ge-detector's efficiency
International Nuclear Information System (INIS)
The dependence of the efficiency of a coaxial IGC-30 Ge detector on the direction of gamma quanta entry, their energy and the distance from the source is examined. A set of point sources QCR-2 (Amersham, UK) has been used which is arranged consecutively in two perpendicular planes passing through the detector axis, at a distance of 0.1 - 1.3 m (pace 0.1) from its geometric centre for 16 different angles in every plane. Dependence curves of the efficiency on the angle of gamma-quanta hits are obtained for energies 60, 81, 122, 356, 662, 834, 1173 and 1332 keV. Changes in efficiency connected with spatial dividing ability are found out. Using the least squares' method the expected spatial distribution of efficiency is examined with a level of authenticity P > 0.9. The possible causes for the efficiency change and its possible effect on the measurements' precision are discussed. (author).
1993-12-02
Simulation study on retention and reflection from tungsten carbide under high fluence of helium ions
Energy Technology Data Exchange (ETDEWEB)
We have studied, by a Monte Carlo simulation code ACAT-DIFFUSE, the fluence-dependence of the amount of retained helium atoms in tungsten carbide at room temperature under helium ion bombardment. The retention behavior may be understood qualitatively in terms of irradiation-dependent diffusion coefficient assumed and range. The emission processes from tungsten carbide under helium ion irradiation derived were compared with each other. We have discussed the retention curves for incident energy of 5 keV at incident angles of 0deg and 80deg and of 500 eV at 0deg. The energy spectra of helium atoms reflected from tungsten carbide for incident energy of 500 eV at 0deg and 80deg were compared with those from graphite and tungsten. (author)
2000-08-01
Resonant neutralization of He ions into excited states at Cu(110) and Ni(110) surfaces
Energy Technology Data Exchange (ETDEWEB)
He ions incident at grazing angles on Cu(110) and Ni(110) surfaces are neutralised into triplet and singlet states, of which the 3p, 3d and 4d upper states are accessible to optical spectroscopy. In the energy range from 500 eV to 15 keV no significant energy dependence of the relative intensities of singlet and triplet lines was observed for scattering on Cu(110). The intensities from Ni(110) are higher and the singlet to triplet intensity ratio of the 3d to 2p transition is about 6% smaller than that from Cu(110). The results can be explained well by assuming resonant charge capture into excited He and intermediate formation of negative He/sup -/ states.
1984-03-01
Resonant neutralization of He ions into excited states at Cu(110) and Ni(110) surfaces
International Nuclear Information System (INIS)
He ions incident at grazing angles on Cu(110) and Ni(110) surfaces are neutralised into triplet and singlet states, of which the 3p, 3d and 4d upper states are accessible to optical spectroscopy. In the energy range from 500 eV to 15 keV no significant energy dependence of the relative intensities of singlet and triplet lines was observed for scattering on Cu(110). The intensities from Ni(110) are higher and the singlet to triplet intensity ratio of the 3d to 2p transition is about 6% smaller than that from Cu(110). The results can be explained well by assuming resonant charge capture into excited He and intermediate formation of negative He"- states. (orig.).
1983-07-01
Recent advance of focused ion beam technology in maskless deposition and patterning
International Nuclear Information System (INIS)
The present article will review recent advances in focused ion beam (FIB) technology. With increasing demands for scale of integration, microfabrication technology is becoming more important and various new microfabrication tools and processing techniques are desired. FIB is one of the promising tools for future microfabrication technology. This provides maskless patterning capability, which is of importance for process simplification, nanofabrication and in the development of in situ vacuum processing. In situ vacuum processing systems are being developed by combining FIB and a molecular beam epitaxy system. Radiation damage may limit applications of FIB. However, it was demonstrated that low energy FIB (<1 keV) with very high brightness was reached and promising results for low damage processing have been obtained. (orig.).
British Library Electronic Table of Contents (United Kingdom)
Although the outer surface of single-walled carbon nanotubes (atomically thin cylinders of carbon) can be involved in a wide range of chemical reactions, it is generally thought that the interior surface of nanotubes is unreactive. In this study, we show that in the presence of catalytically active atoms of rhenium inserted into nanotubes, the nanotube sidewall can be engaged in chemical reactions from the inside. Aberration-corrected high-resolution transmission electron microscopy operated at 80?keV allows visualization of the formation of nanometre-sized hollow protrusions on the nanotube sidewall at the atomic level in real time at ambient temperature. Our direct observations and theoretical modelling demonstrate that the nanoprotrusions are formed in three stages: (i) metal-assisted d...
2011-01-01
Radiopharmaceuticals labelled with positron emitting radionuclides
International Nuclear Information System (INIS)
A brief survey is presented of the methods of preparation and of the applications of radiopharmaceuticals labelled with short-lived positron radionuclides "1"1C, "1"8F, "1"3N and "1"5O which, thanks to their energy level schemes, short half-life and the 511 keV photon radiation energy are almost ideal tracers in modern nuclear medicine and pharmacology. In conjunction with computerized tomography, they represent one of the most sensitive diagnostic imaging methods, the so-called positron emission tomography. In addition, their incorporation in the molecule of a pharmaceutical does not change the biological and chemical properties of the original molecule unlike those of radiopharmaceuticals labelled with technetium, iodine, etc. (author). 125 refs.
1989-01-01
RHEED, AES and XPS studies of the passive films formed on ion implanted stainless steel
International Nuclear Information System (INIS)
P-implantation (10"1"7 ions cm"-"2, 40 KeV) into 304 stainless steel (ss) has been carried out, and an amorphous surface alloy was formed. Polarization studies in deaerated 1N H_2SO_4+ 2% NaCl showed that P-implantation improved both the general and localized corrosion resistance of 304 ss. A comparative study has been carried out between the implanted and unimplanted steel to determine what influence P-implantation has upon the properties of the passive film formed 1N H_2SO_4. The influence of Cl ions on pre-formed passive films was also studied. RHEED, XPS and AES were used to evaluate the nature of the passive films formed in these studies.
2005-05-26
RHEED, AES and XPS studies of the passive films formed on ion implanted stainless steel
Energy Technology Data Exchange (ETDEWEB)
P-implantation (10/sup 17/ ions cm/sup -2/, 40 KeV) into 304 stainless steel (ss) has been carried out, and an amorphous surface alloy was formed. Polarization studies in deaerated 1N H/sub 2/SO/sub 4/+ 2% NaCl showed that P-implantation improved both the general and localized corrosion resistance of 304 ss. A comparative study has been carried out between the implanted and unimplanted steel to determine what influence P-implantation has upon the properties of the passive film formed 1N H/sub 2/SO/sub 4/. The influence of Cl ions on pre-formed passive films was also studied. RHEED, XPS and AES were used to evaluate the nature of the passive films formed in these studies.
1981-12-01
Photosensitivity and imaging characteristics of ion-implanted PLZT ceramics
International Nuclear Information System (INIS)
We reported in previous papers that both the near-uv and the visible photosensitivities of ferroelectric-phase PLZT (lead lanthanum zirconate titanate) ceramics are increased by as much as four orders of magnitude by ion implantation or a combination of thermal diffusion of Al and ion implantation. New results are presented here on high-energy (1 MeV) implants of Al and Ni and coimplants of Al + Ne and Ni + Ne, and these results are compared with earlier 500 keV implants of Al and Cr and coimplants of Al + Ne and Cr + Ne as surface modification techniques for increasing the visible photosensitivity of PLZT. The important role of grain size in determining optimum contrast and resolution of stored optical information is described in terms of new experimental results.
1985-08-12
Particle emission from low energy proton bombardment of TiH{sub 2} and TiD{sub 2}
Energy Technology Data Exchange (ETDEWEB)
TiH{sub 2} and TiD{sub 2} thick targets were bombarded with 100 to 200 keV protons. Evidence for nuclear reactions was obtained by means of a surface barrier particle detector. Proton irradiation of TiD{sub 2} produced the following observations: {alpha} particle emission identified as (p, {alpha}) reactions from {sup 11}B and {sup 7}Li impurities in the target at ppm concentrations; and {approx}3 MeV proton and {approx}1 MeV triton emission from secondary D-D reactions caused by elastic scattering of the primary proton with a target deuteron. A 3.9 MeV {alpha} particle peak measured by others was not observed. (author)
2002-03-01
Particle and X-ray damage in pn-CCDs
Energy Technology Data Exchange (ETDEWEB)
The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.
2000-01-11
Partial wave expansion of ion-atom elastic scattering in solids
International Nuclear Information System (INIS)
Elastic scattering cross sections of keV protons in solids (Z=3-82) are calculated using the partial wave expansion technique and the ''muffin-tin'' bound-atom potential. The differential cross sections for small scattering angles of less than 10deg are smaller than those with the Ziegler-Biersack-Littmark potential at all energies and for all solids, although, for larger angles, the two cross sections agree with each other. The mean free paths of the protons in the solids, obtained from the total cross sections, decrease very slowly with decreasing energy. Furthermore, at low energies they approach half the nearest-neighbor distance, which is taken as the radius of the augmented plane wave sphere in the muffin-tin model of crystalline solids. (orig.).
Optical-Model Description of Time-Reversal Violation
A time-reversal-violating spin-correlation coefficient in the total cross section for polarized neutrons incident on a tensor rank-2 polarized target is calculated by assuming a time-reversal-noninvariant, parity-conserving ``five-fold" interaction in the neutron-nucleus optical potential. Results are presented for the system $n + {^{165}{\\rm Ho}}$ for neutron incident energies covering the range 1--20 MeV. From existing experimental bounds, a strength of $2 \\pm 10$ keV is deduced for the real and imaginary parts of the five-fold term, which implies an upper bound of order $10^{-4}$ on the relative $T$-odd strength when compared to the central real optical potential.
1994-01-01
Milling materials using CO{sub 2} clusters; Materialbearbeitung durch Clusterionenbeschuss
Energy Technology Data Exchange (ETDEWEB)
The Sputter coefficient of accelerated CO{sub 2} cluster ions hitting surfaces of various materials is investigated. For copper it varies proportional to the 2nd power of the energy between 155 and 260 keV. The rate of erosion for different target materials varies by two orders of magnitude from tungsten to PMMA. Diamond is eroded fairly quickly, while aluminum is eroded less than corundum (Al{sub 2}O{sub 3}). No simple correlation of the sputter coefficient on the bulk material properties is found. For copper the angular distribution of sputtered material is measured and found to be following roughly a cosine distribution. By using masks different microstructures have been produced in cobalt-samarium magnets, diamond and glass. (orig.)
1993-10-01
Measurement of liquid nitrogen level by radiation
Energy Technology Data Exchange (ETDEWEB)
The measurement of level in the liquid nitrogen vessel has been carried out by the weight conversion method using weigher or by putting directly a stick in the vessel. On a large CE tank, the pressure difference was read by manometer. These methods can not be used when the vessel does not put on the weigher or the pipe for manometer is stopped. We noticed the interaction between radiation ({gamma}-ray) and substance and applied it to determine the liquid nitrogen level. The results proved it the easy method for measurement of the level in the large CE tank. Cesium 137 ({gamma}-ray energy: 662 keV) was used as the radiation source. {gamma}-ray transmission dose was determined by GM survey meter. The liquid nitrogen level could be determined by using the change of the transmission dose with amount of liquid nitrogen. (S.Y.)
1995-07-01
Energy Technology Data Exchange (ETDEWEB)
Making use of a lead slowing-down spectrometer coupled to a 46 MeV electron linear accelerator and a back-to-back type double fission chamber, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40 % full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, for which the evaluated and the experimental data were broadened by the energy resolution function of the spectrometer. (author)
1997-12-31
Energy Technology Data Exchange (ETDEWEB)
Making use of a back-to-back type double fission chamber and a lead slowing-down spectrometer driven by a 46 MeV electron linear accelerator, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40 % full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, whose evaluated and measured data were broadened by the energy resolution function of the spectrometer.
1998-08-01
Energy Technology Data Exchange (ETDEWEB)
Making use of a back-to-back type double fission chamber and a lead slowing-down spectrometer driven by a 46 MeV electron linear accelerator, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40% full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, whose evaluated and measured data were broadened by the energy resolution function of the spectrometer. (author)
1999-02-01
Investigation on corrosion resistance of amorphous films prepared by ion beam mixing
International Nuclear Information System (INIS)
Fe-Cr amorphous films have been formed by both in situ evaporation of multilayered films and ion beam mixing in a target chamber of a 200 keV implanter. The effects of Cr content and ion irradiation on the amorphization of films were examined by transmission electron microscope (TEM). Corrosion of film was investigated by means of a potential dynamic polarization. Corrosion resistance of amorphous film in 0.5 mol H-2SO-4 solution is considerably increased than that of pure iron. Using X ray photoelectron spectroscopy (XPS) corrosion resistance in atmosphere of amorphous Fe-Cr passive films formed by P"+ mixing was studied. Results show that the richness of Cr and P exist at the surface of Fe-Cr film.
1991-01-01
Infrared monitoring of the Doublet III beam armor plate
Energy Technology Data Exchange (ETDEWEB)
An 80 keV, 3.6 MW neutral beam injection system has recently been installed on Doublet III, and the installation of a second system is scheduled within several months. Armor plate consisting of /approximately equals/100 graphite tiles (10 cm x 10 cm) coated with TiC has been plated over portions of the inner vacuum wall lying in the line of sight of the ion sources. In order to monitor the condition of the armor plate an infrared camera and a set of optical pyrometers have been installed alongside the beamline and view the armor plate through a CaF/sub 2/ window. The pyrometers measure the temperature of the armor plate associated with the maximum of the intensity distribution of each ion source.
1981-01-01
International Nuclear Information System (INIS)
It has been demonstrated that, by incorporating a thin #approx#20 nm Si_1_-_yC_y (with y as low as 0.1%) layer at the deep indium implant end-of-range (EOR) region, the EOR defects and enhanced diffusion behavior associated with indium implant can be eliminated. The Si_1_-_yC_y layer was grown epitaxially followed by a silicon epitaxy cap of 60 nm. Indium implantations were performed at 1x10"1"4 cm"-"2 at 115 keV followed by spike annealing at 1050 deg. C. The experimentally observed EOR defect and enhanced diffusion elimination are explained based on the undersaturation of implantation-induced silicon interstitials with the presence of substitutional carbon at the Si_1_-_yC_y layer.
2003-11-17
International Nuclear Information System (INIS)
We have simulated the transient enhanced diffusion (TED) of boron fluoride (BF_2"+) implanted in crystalline and germanium amorphized silicon. Based on recently published models, the effect of fluorine on boron diffusion in silicon has been introduced and a modelling has been suggested. In order to simulate the boron experimental profiles, we have assumed that fluorine forms clusters involving interstitial boron which reduces the junction depth. Experimental results indicate that fluorine behaviour depends on amorphization energy. Moreover, even no germanium preamorphization is performed, silicon is still amorphized by fluorine species. Hence, BF_2"+ implantation leads to an amorphous/crystalline (a/c) interface near the surface. An improvement of published models is suggested taking into account fluorine effects. The simulations satisfactory reproduce the SIMS experimental profiles for a large scale of experimental conditions.
2002-01-01
Implant damage and redistribution of indium in indium-implanted thin silicon-on-insulator
Energy Technology Data Exchange (ETDEWEB)
The indium implant damage and diffusion behavior in thin silicon-on-insulator (SOI) with a 200 nm top silicon layer were studied for different implantation energies and doses. Rutherford backscattering spectrometry in the channeling mode (RBS/C) was used to characterize the implant damage before and after annealing. Secondary ion mass spectrometry (SIMS) was used to study the indium transient enhanced diffusion (TED) behavior in the top Si layer of the SOI structure. An anomalous redistribution of indium after relatively high energy (200 keV) and dose (1 x 10{sup 14} cm{sup -2}) implantation was observed in both bulk Si and SOI substrates. However, there exist differences in these two substrates that are attributable to the more predominant out-diffusion of indium as well as the influence of the buried oxide layer in the SOI structure.
2004-12-15
Implant damage and redistribution of indium in indium-implanted thin silicon-on-insulator
International Nuclear Information System (INIS)
The indium implant damage and diffusion behavior in thin silicon-on-insulator (SOI) with a 200 nm top silicon layer were studied for different implantation energies and doses. Rutherford backscattering spectrometry in the channeling mode (RBS/C) was used to characterize the implant damage before and after annealing. Secondary ion mass spectrometry (SIMS) was used to study the indium transient enhanced diffusion (TED) behavior in the top Si layer of the SOI structure. An anomalous redistribution of indium after relatively high energy (200 keV) and dose (1 x 10"1"4 cm"-"2) implantation was observed in both bulk Si and SOI substrates. However, there exist differences in these two substrates that are attributable to the more predominant out-diffusion of indium as well as the influence of the buried oxide layer in the SOI structure.
2004-12-15
G-factor of the 21/2/sup +/ isomer in /sup 203/Pb
Energy Technology Data Exchange (ETDEWEB)
The g-factor of the 21/2/sup +/ state at 1921.9 keV in /sup 203/Pb has been measured through the time differential perturbed angular distribution technique in an external magnetic field B=2.028 T. The measured g-factor g=-0.063(2) indicates a predominantly three neutron hole configuration described by the wave function 0.68vertical strokei/sup -1//sub 13/2/f/sup -2//sub 5/2/>+-0.73vertical strokei/sup -1//sub 13/2/f/sup -1//sub 5/2/p/sup -1//sub 3/2/>.
1986-12-01
Fourier analysis of energy transfer data obtained by simulating a 14-MeV #alpha#-particle in water
International Nuclear Information System (INIS)
Data from Monte Carlo transport codes are used to model radiobiological effects. We previously reported the Fourier analysis of ionization data generated by simulating a 500-keV proton traversing water. Here, we extend Fourier analysis to energy transfer data of another radiation type, a 14-MeV #alpha#-particle. A radiobiological model based on this frequency-domain analysis views cell as an information processing system . It lends itself naturally to traditional engineering analyses. One engineering principle-the output response of a linear system to random signal-is applied here to explain the fact that there is measurable difference in the magnitude of the biological effectiveness when a given biological system is irradiated with two different radiation types of the same Linear Energy Transfer (LET).
2010-01-15
Focused ion beam preparation of inclined planes in semiconductor materials
International Nuclear Information System (INIS)
Focused ion beam (FIB) micromachining has been used to produce inclined planes on semiconductor surfaces. A 10 keV FIB system, utilising a Ga"+ liquid metal ion source (LMIS), was employed. The ramped surfaces were prepared by digitally deflecting the ion beam in a serpentine fashion over a rectangular area and incrementing the time the beam spends at a pixel, dwell time, line by line. For the conditions used, control in micromachining the inclination of the ramps to the starting horizontal surface is of the order of 1 arc s per scan of the FIB over the area of interest. The possibility of using such surfaces prepared by FIB, along with vacuum growth techniques such as molecular beam epitaxy (MBE), for application to strain relief structures and lateral device production is discussed. (author).
Electronics Personal Dosemeter (EPD-N) Test and Evaluation Report
Energy Technology Data Exchange (ETDEWEB)
Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization then used at another site.
2003-04-08
Electronic structure, Compton profiles and optical properties of TaC and TaN
International Nuclear Information System (INIS)
Isotropic Compton profiles of TaC and TaN have been measured for the first time, at an intermediate resolution, using 662 keV #gamma#-radiation. Energy bands, density of states and Fermi surface topology of TaC and TaN have been computed using linear combination of atomic orbitals with density functional theory and full potential linearised augmented plane wave method. Both band structure calculations predict the metallic character of TaC and TaN. The electron momentum densities calculated using various approaches of density functional theory are compared with the present measurements. On the basis of Mulliken's population, it is also seen that TaC has more covalent bonding than TaN. The optical properties computed using full potential linearised augmented plane wave method are explained in terms of intraband transitions.
2010-11-01
Energy Technology Data Exchange (ETDEWEB)
The properties of negative-ion beams are very important for designing negative-ion apparatus and applications of negative-ion beams, especially, electron detachment cross-sections at the interaction between negative-ion beams and gas particles in the transport system, and secondary-electron emission factors when negative ions are incident on solid surfaces. These properties of negative-ion beams were investigated experimentally as a function of the ion energy under 50 keV. The single electron detachment cross-sections are almost constant in the other of 10[sup -15] cm[sup 2] in this energy range, but double electron detachment cross-sections increase in proportion to the ion velocity and much smaller than the single one. As for the secondary-electron emission factor, the emission factors for negative-ion beam are found to be larger by 1 than those for positive-ion beams. (author).
1994-01-01
International Nuclear Information System (INIS)
The properties of negative-ion beams are very important for designing negative-ion apparatus and applications of negative-ion beams, especially, electron detachment cross-sections at the interaction between negative-ion beams and gas particles in the transport system, and secondary-electron emission factors when negative ions are incident on solid surfaces. These properties of negative-ion beams were investigated experimentally as a function of the ion energy under 50 keV. The single electron detachment cross-sections are almost constant in the other of 10"-"1"5 cm"2 in this energy range, but double electron detachment cross-sections increase in proportion to the ion velocity and much smaller than the single one. As for the secondary-electron emission factor, the emission factors for negative-ion beam are found to be larger by 1 than those for positive-ion beams. (author).
1994-01-01
Electrical properties of focused-ion-beam boron-implanted silicon
International Nuclear Information System (INIS)
Electrical properties of 16 keV, focused-ion-beam (FIB) (beam diameter: 1 #mu#m, current density: 50 mA/cm"2) boron-implanted silicon layers have been investigated as a function of beam scan speed and ion dose, and compared with those obtained by conventional implantation (current density: 0.4 #mu#A/cm"2). High electrical activation of the FIB implanted layers is obtained by annealing below 800"0C as a result of the increase in amorphous zones created in the implanted layers. Amorphous zone overlapping is assumed to occur at FIB implantation doses of 3 - 4 x 10"1"5 ions/cm"2 from the results of electrical activation and the carrier profile of implanted regions annealed at low temperature, if beam scan speed is lowered to about 10"-"2 cm/s. (author).
Effects on focused ion beam irradiation on MOS transistors
Energy Technology Data Exchange (ETDEWEB)
The effects of irradiation from a focused ion beam (FIB) system on MOS transistors are reported systematically for the first time. Three MOS transistor technologies, with 0.5, 1, and 3 {mu}m minimum feature sizes and with gate oxide thicknesses ranging from 11 to 50 nm, were analyzed. Significant shifts in transistor parameters (such as threshold voltage, transconductance, and mobility) were observed following irradiation with a 30 keV Ga{sup +} focused ion beam with ion doses varying by over 5 orders of magnitude. The apparent damage mechanism (which involved the creation of interface traps, oxide trapped charge, or both) and extent of damage were different for each of the three technologies investigated.
1997-04-01
Effects of ion irradiation on the diffusion of pre-implanted B atoms in crystalline silicon
International Nuclear Information System (INIS)
N-type crystalline Si (100) implanted with 5 keV B ions was subsequently irradiated with MeV Si, O and F ions. The B atom profiles were measured by means of secondary ion mass spectrometer after the treatment of rapid thermal annealing. The results show that the transient enhanced diffusion of B atoms is effectively limited by the post-implantation of high energy ions at high dose. At the same irradiation conditions, it is found that the existence of a SiO_2 layer in the near surface of Si is even more effective in suppressing the transient enhanced diffusion of the doped B atoms. The results are qualitatively discussed in combination with the analyses of RBS/c measurements and calculation of the DICADA code
2001-12-01
Effect of pressure on the valence state of Yb in YbPd_2Si_2
International Nuclear Information System (INIS)
The intermediate valent behaviour of YbPd_2Si_2 has been studied under pressure in the temperature range from 1.2 K to 90 K by using the 84 keV Moessbauer transition in "1"7"0Yb. At 54 kbar and 4.2 K we obtain an increase of the electric field gradient (EFG) by a factor of #approx =# 3. In addition, the EFG varies strongly with temperature, in contrast to the behaviour at ambient pressure. At 1.2 K a change of the hyperfine pattern is observed indicating a magnetic character of the Yb ion. These results provide evidence of a pressure induced change of the valence state close to 3+. (orig.).
Monte Carlo calculations using the codes PENELOPE and GEANT4 have been performed to characterize the dosimetric properties of monoenergetic photon point sources in water. The dose rate in water has been calculated for energies of interest in brachytherapy, ranging between 10 keV and 2 MeV. A comparison of the results obtained using the two codes with the available data calculated with other Monte Carlo codes is carried out. A chi2-like statistical test is proposed for these comparisons. PENELOPE and GEANT4 show a reasonable agreement for all energies analyzed and distances to the source larger than 1 cm. Significant differences are found at distances from the source up to 1 cm. A similar situation occurs between PENELOPE and EGS4.
2006-01-01
Determination of Proper Peaking Time for Ultra Lege detector at Medium Energies
International Nuclear Information System (INIS)
Reducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the optimum peaking time for particular detector systems is important. For this purpose, pure Se and Zn elements were excited by 59.5 keV ?-rays from a 50 mCi 241Am annular radioactive source in this study. The characteristic x-rays emitted from pure Se and Zn elements were detected by using an ultra low energy Ge (Ultra-LEGe) detector connecting Tennelec TC 244 spectroscopy amplifier at different peaking time modes. Overall pulse widths were determined by HM 203-7 oscilloscope connecting amplifier. The proper peaking time for ultra low energy germanium detector (Ultra-LEGe) is determined about 4 ?s.
2008-08-25
Design and fabrication of large ultra-thin PIN detector with membrane stress deviation
Energy Technology Data Exchange (ETDEWEB)
In this paper, the design of large thin PIN detector with a membrane stress avoidance configuration is proposed, and the related device fabrication process is developed. Ultra-thin PIN detector {approx} 1.13 cm{sup 2} in area is fabricated on a thin ( {approx} 35{mu}m) silicon membrane, and characterized. Detector performance improvement has been successfully demonstrated. With the membrane stress avoidance design, the improved detector exhibits a leakage of 6nA, which is at least 5 times lower than that of detector of identical junction area. The new detector features a full depleted capacitance of 110 pF, and a FWHM of 40.86 keV energy resolution for 5.486 MeV alpha particle spectrography.
2010-09-15
Depth dependence of {l_brace}311{r_brace} defect dissolution
Energy Technology Data Exchange (ETDEWEB)
A deep band of {l_brace}311{r_brace} defects was created 520 nm below the silicon surface with a 350 keV Si implant followed by a cluster-forming rapid thermal anneal (800 C, 1000 s). Chemical etching was used to vary the depth to the surface of the {l_brace}311{r_brace}-defect band. Afterwards, the defect dissolution was investigated at 750 C for different times. Varying the depth in this fashion assures that only the depth and no other feature of the cluster distribution is changed. The {l_brace}311{r_brace} defects were analyzed by plan-view, transmission electron microscopy. We show that the dissolution time of the {l_brace}311{r_brace}-defect band varies linearly with depth, confirming that surface recombination controls the dissolution and is consistent with analogous observations of transient enhanced diffusion.
2001-09-03
Depth dependence of #left brace#311#right brace# defect dissolution
International Nuclear Information System (INIS)
A deep band of #left brace#311#right brace# defects was created 520 nm below the silicon surface with a 350 keV Si implant followed by a cluster-forming rapid thermal anneal (800 C, 1000 s). Chemical etching was used to vary the depth to the surface of the #left brace#311#right brace#-defect band. Afterwards, the defect dissolution was investigated at 750 C for different times. Varying the depth in this fashion assures that only the depth and no other feature of the cluster distribution is changed. The #left brace#311#right brace# defects were analyzed by plan-view, transmission electron microscopy. We show that the dissolution time of the #left brace#311#right brace#-defect band varies linearly with depth, confirming that surface recombination controls the dissolution and is consistent with analogous observations of transient enhanced diffusion.
2001-09-03
Comparative evolution of various CCD image sensors hardening techniques with ionizing radiation
International Nuclear Information System (INIS)
This paper reviews various techniques to harden Charged Coupled Device (CCD) sensors and the results after irradiation of three Thomson n buried channel CCDs having a different degree of hardening. It describes the major irradiation effects on CCD performances and it makes a comparison of the results between the different hardening levels. It shows good results on dark voltage after ionizing radiation for TH 7863M device hardened both by design and by operating conditions (MPP mode) with respect to the standard device TH 7863A. The irradiations were performed with "6"0Co or X-ray (10 keV) sources on devices in operating mode. (author). 3 refs., 8 figs.
International Nuclear Information System (INIS)
Measurements of absolute differential cross sections for H"+-H_2 direct, single-, and double-charge-transfer scattering at 0.5, 1.5, and 5.0 keV are reported at laboratory scattering angles less than 1 degree with an angular resolution of approximately 0.02 degree. The cross sections exhibit deep interference oscillations in single-charge-transfer scattering, but no such oscillations are present in direct and double-charge-transfer scattering. Theoretical cross sections derived using the diatoms-in-molecules method to describe the molecular states in a semiclassical molecular-orbital three-state close-coupling model within a semiclassical framework agree satisfactorily with the experimental results.
Characterization of focused-ion-beam-induced damage in n-type silicon using Schottky contact
International Nuclear Information System (INIS)
The effects of focused-ion-beam-induced damage on electrical properties of n-type Si are investigated by Schottky contacts. Crystalline Si is exposed to 10-30 keV focused ion beam (FIB), followed by Pt deposition under vacuum of 4x10"-"4 Pa. From current-voltage-temperature measurements, barrier heights of the Schottky contacts are found to increase almost linearly as the FIB energy increases, with the maximum increment of 0.29 eV. The increase is suggested to be related to the arising of acceptorlike defects and an amorphous layer due to FIB damages. A theoretical model is set up to quantitatively describe the barrier height changes.
2006-04-10
Channeling studies of radiation damage in metal-silicides
Channeling effect measurements have been employed to investigate radiation damage produced by 100-keV Ar ions in preferred oriented polycrystalline metal-silicide layers, such as Pd/sub 2/Si and NiSi/sub 2/ layers formed on single-crystalline Si. For room-temperature implantation, an amount of the damage in Pd/sub 2/Si layers was found to saturate at doses between 3 x 10/sup 14/ and 1 x 10/sup 17/ ions/cm/sup 2/, where the minimum aligned yield of 1.5-MeV He ions was nearly 40% of the random one. On the contrary, it was observed that the NiSi/sub 2/ layers became amorphous at doses higher than 3 x 10/sup 15/ ions/cm/sup 2/. These results were confirmed by the reflection electron diffraction analyses.
1978-01-01
Channeling studies of radiation damage in metal-silicides
International Nuclear Information System (INIS)
Channeling effect measurements have been employed to investigate radiation damage produced by 100-keV Ar ions in preferred oriented polycrystalline metal-silicide layers, such as Pd_2Si and NiSi_2 layers formed on single-crystalline Si. For room-temperature implantation, an amount of the damage in Pd_2Si layers was found to saturate at doses between 3 x 10"1"4 and 1 x 10"1"7 ions/cm"2, where the minimum aligned yield of 1.5-MeV He ions was nearly 40% of the random one. On the contrary, it was observed that the NiSi_2 layers became amorphous at doses higher than 3 x 10"1"5 ions/cm"2. These results were confirmed by the reflection electron diffraction analyses.
Broad-band hard X-ray reflectors
DEFF Research Database (Denmark)
Interest in optics for hard X-ray broad-band application is growing. In this paper, we compare the hard X-ray (20-100 keV) reflectivity obtained with an energy-dispersive reflectometer, of a standard commercial gold thin-film with that of a 600 bilayer W/Si X-ray supermirror. The reflectivity of the multilayer is found to agree extraordinarily well with theory (assuming an interface roughness of 4.5 Angstrom), while the agreement for the gold film is less, The overall performance of the supermirror is superior to that of gold, extending the band of reflection at least a factor of 2.8 beyond that of the gold, Various other design options are discussed, and we conclude that continued interest in the X-ray supermirror for broad-band hard X-ray applications is warranted.
1997-01-01
Boron-enhanced-diffusion of boron: The limiting factor for ultra-shallow junctions
Energy Technology Data Exchange (ETDEWEB)
Reducing implant energy is an effective way to eliminate transient enhanced diffusion (TED) due to excess interstitials from the implant. It is shown that TED from a fixed Si dose implanted at energies from 0.5 to 20 keV into boron doping-superlattices decreases linearly with decreasing Si ion range, virtually disappearing at sub-keV energies. However, for sub-keV B implants diffusion remains enhanced and x{sub j} is limited to {ge} 100 nm at 1,050 C. The authors term this enhancement, which arises in the presence of B atomic concentrations at the surface of {approx} 6%, Boron-Enhanced-Diffusion (BED).
1997-12-01
Boron transient enhanced diffusion in heavily phosphorus doped silicon
International Nuclear Information System (INIS)
A study has been made of B transient enhanced diffusion (TED) in heavily P-doped Si using secondary ion mass spectroscopy (SIMS) and positron annihilation spectroscopy (PAS). The P-doped silicon was implanted with boron ions of 40 keV energy to a dose of 3 x 10"1"4 cm"-"2, and then annealed at temperatures ranging from 700--1,000 C in a N_2 ambient for varying durations. As P doping concentration increased from 3 x 10"1"9 to 1 x 10"2"0 cm"-"3, boron diffusivity and the immobile boron fraction decreased. The experimental results are inconsistent with the predictions of the Fermi-level model and suggest that the clustering between B atoms and Si interstitials should be invoked in order to explain the immobile portion of the B peak during TED.
1996-12-02
Atomic scale simulations of arsenic ion implantation and annealing in silicon
International Nuclear Information System (INIS)
We present results of multiple-time-scale simulations of 5, 10 and 15 keV low temperature ion implantation of arsenic on silicon (100), followed by high temperature anneals. The simulations start with a molecular dynamics (MD) calculation of the primary state of damage after 10ps. The results are then coupled to a kinetic Monte Carlo (MC) simulation of bulk defect diffusion and clustering. Dose accumulation is achieved considering that at low temperatures the damage produced in the lattice is stable. After the desired dose is accumulated, the system is annealed at 800 degrees C for several seconds. The results provide information on the evolution for the damage microstructure over macroscopic length and time scales and affords direct comparison to experimental results. We discuss the database of inputs to the MC model and how it affects the diffusion process.
2004-12-15
Atomic processes in high temperature plasmas
International Nuclear Information System (INIS)
Much theoretical and experimental efforts have been expended in recent years to study those atomic processes which are specially relevant to understanding high temperature laboratory plasmas. For magnetically confined fusion plasmas, the temperature range of interest spans from the hundreds of eV at plasma edges to 10 keV at the center of the plasma, where most of the impurity ions are nearly fully ionized. These highly stripped ions interact strongly with electrons in the plasma, leading to further excitation and ionization of the ions, as well as electron capture. Radiations are emitted during these processes, which easily escape to plasma container walls, thus cooling the plasma. One of the dominant modes of radiation emission has been identified with dielectronic recombination. This paper reviews this work.
1990-01-01
Ar/sup +/ ion beam induced silicide formation mechanism at the Pf-Si interface
Energy Technology Data Exchange (ETDEWEB)
Evaporated palladium films of 45 nm thickness on Si(111) were irradiated using 78 keV Ar/sup +/ ions with doses in the range of 1 x 10/sup 15/ to 1.5 x 10/sup 16/ cm/sup -2/ for the purpose of studying silicide formation. Rutherford backscattering analysis shows that intermixing has occurred across the Pd-Si interface at room temperature. The mixing behaviour increases with increasing dose of the bombarding ions, which agrees well with a theoretical model of isotropic cascade mixing for palladium, and radiation-enhanced diffusion associated with an interstitial mechanism for silicon.
1989-01-01
International Nuclear Information System (INIS)
Charge carrier profiles are measured for boron implanted into silicon (E = 30 keV, dose range 5 x 10"1"5 to 2 x 10"1"6 B/cm"2) after rapid isothermal annealing using halogen lamps. Maximum temperatures between 1000 and 1300 "0C and holding times at T/sub max/ of 5 and 20 s are used for the annealing treatment. In a few additional experiments flash lamp annealing at 1350 "0C (pulse duration 20 ms) is investigated. By comparison of the experimental profiles with computer simulations using the SUPREM II program transient enhanced diffusion of boron could be detected in all investigated cases. Maximum charge carrier concentrations above the equilibrium solubility of boron are observed and are discussed. (author).
International Nuclear Information System (INIS)
This paper reports measurements of absolute differential cross sections for electron capture and loss for fast hydrogen atoms incident on H_2, N_2, O_2, Ar, and He. Cross sections have been determined in the 2.0- to 5.0-keV energy range over the laboratory angular range 0.02 degree--2 degree, with an angular resolution of 0.02 degree. The high angular resolution allows us to observe structure at small angles in some of the cross sections. Comparison of the present results with those of other authors generally shows very good agreement.
A study of methyl formate in astrochemical environments
Several complex organic molecules are routinely detected in high abundances towards hot cores and hot corinos. For many of them, their paths of formation in space are uncertain, as gas phase reactions alone seem to be insufficient. In this paper, we investigate a possible solid-phase route of formation for methyl formate (HCOOCH3). We use a chemical model updated with recent results from an experiment where simulated grain surfaces were irradiated with 200 keV protons at 16 K, to simulate the effects of cosmic ray irradiation on grain surfaces. We find that this model may be sufficient to reproduce the observed methyl formate in dark clouds, but not that found in hot cores and corinos.
2011-01-01
A principle of charged particle trapping by RF electromagnetic field in the spherical cavity
Energy Technology Data Exchange (ETDEWEB)
A new principle of particle trapping in the simple spherical cavity using both electric and magnetic components of radiofrequency electromagnetic field is proposed. The electric component of H {sub 12} oscillating mode drives the fast particle oscillations, while the magnetic component synchronously bends the trajectories to the cavity center. A specially developed theory of particle stability predicts dense and energetic electron cluster in the trap. Numerical simulations of particle dynamics in the complete electromagnetic field taking into account both space charge and particle-induced magnetic field are in good agreement with the analytic results, giving a density of 2.6*10{sup 1} electrons/cm{sup 3} and an average kinetic energy of around 30 keV at an operating frequency of 3 GHz. Being used at lower frequency, spherical cavity can trap protons and heavier ions too, but with lower density and kinetic energy.
2005-11-21
Triple ion-beam studies of radiation damage in 9Cr2WVTa ferritic/martensitic steel
Energy Technology Data Exchange (ETDEWEB)
To simulate radiation damage under a future Spallation Neutron Source (SNS) environment, irradiation experiments were conducted on a candidate 9Cr-2WVTa ferritic/martensitic steel using the Triple Ion Facility (TIF) at ORNL. Irradiation was conducted in single, dual, and triple ion beam modes using 3.5 MeV Fe{sup ++}, 360 keV He{sup +}, and 180 keV H{sup +} at 80, 200, and 350{degrees}C. These irradiations produced various defects comprising black dots, dislocation loops, line dislocations, and gas bubbles, which led to hardening. The largest increase in hardness, over 63 %, was observed after 50 dpa for triple beam irradiation conditions, revealing that both He and H are augmenting the hardening. Hardness increased less than 30 % after 30 dpa at 200{degrees}C by triple beams, compatible with neutron irradiation data from previous work which showed about a 30 % increase in yield strength after 27.2 dpa at 365{degrees}C. However, the very large ...
1997-11-01
Energy Technology Data Exchange (ETDEWEB)
Austenitic 316LN alloy was ion-irradiated using the unique Triple Ion Beam Facility (TIF) at ORNL to investigate radiation damage effects relevant to spallation neutron sources. The TIF was used to simulate significant features of GeV proton irradiation effects in spallation neutron source target materials by producing displacement damage while simultaneously injecting helium and hydrogen at appropriately high gas/dpa ratios. Irradiations were carried out at 80, 200, and 350 C using 3.5 MeV Fe{sup ++}, 360 keV He{sup +}, and 180 keV H{sup +} to accumulate 50 dpa by Fe, 10,000 appm of He, and 50,000 appm of H. Irradiations were also carried out at 200 C in single and dual ion beam modes. The specific ion energies were chosen to maximize the damage and the gas accumulation at a depth of {approximately} 1 {micro}m. Variations in microstructure and hardness of irradiated specimens were studied using transmission electron microscopy (TEM) and a ...
1997-09-01
Time-of-flight secondary ion mass spectrometry of fatty acids in rat retina
Energy Technology Data Exchange (ETDEWEB)
The retina consists of many kinds of central nervous cells, and some cells contain fatty acids such as palmitic acid, stearic acid and oleic acid. Time-of-flight secondary ion mass spectrometry (TOF-SIMS) has a possibility to detect kinds and quantity of materials in relation to the cell or tissue. We applied TOF-SIMS to detect the palmitic acid, stearic acid and oleic acid in the visual cell of the rat retina. We used 4- and 18-month-old normal Wistar Kyoto rats. After pentobarbital anesthesia, the eyes were enucleated, and immediately put into liquid nitrogen without any fixation and then cut into semithin sections (10 {mu}m) with a cryo-ultramicrotome, and laid it on a silicon wafer plate and air-dried. Ion images were detected with TOF-SIMS. Positive ion images were examined with a Ga{sup +} source at an acceleration voltage of 15 keV. The secondary ion acceleration voltage was 4.5 keV. In the 4-month-old rat, palmitic and stearic acid were ...
2003-01-15
Energy Technology Data Exchange (ETDEWEB)
Neutron capture cross sections of actinides are of great relevance for the Transmutation of Nuclear Waste in Accelerator Driven Systems (ADS) and Generation-IV reactors. The neutron capture cross sections of {sup 237}Np and {sup 240}Pu in the range of 1 eV to 2 keV were measured at the n-TOF facility with a Total Absorption Calorimeter. The data have been analyzed with the SAMMY code. The corresponding covariance matrices have been generated. The final cross sections are presented and compared to the previously existing ones.The n-TOF {sup 237}Np {sigma}(n,{gamma}) is in agreement with the evaluated data files below 300 eV and its is lower by 10 to 15% up to 2 keV. This discrepancy with the evaluated data files is also observed in the capture cross section derived from the transmission measurements of Gressier et al. In the case of the {sup 240}Pu {sigma}(n,{gamma}), the n-TOF {sigma}(n,{gamma}) agrees within uncertainties with JENDL-3.3 and ...
2008-07-01
Surface excitation correction of the inelastic mean free path in selected conducting polymers
International Nuclear Information System (INIS)
In earlier works, the inelastic mean free path (IMFP) of electrons was determined by elastic peak electron spectroscopy (EPES) using Ni and Ag reference standard samples, but fully neglecting surface excitation. Surface excitation that is characterized by the surface excitation parameter (SEP), and may affect considerably the elastic peak for the sample and the reference material. The SEP parameters of selected conducting polymers (polythiophenes, polyaniline and polyethylene) were determined by EPES using Si and Ge reference samples. Experiments were made with a hemispherical analyzer of energy resolution 100-200 meV in the E = 0.2-2.0 keV energy range. The composition of the sample surfaces was determined by in situ XPS, their surface roughness by AFM. The experimental SEP parameter data of eight polymer samples were determined by our new procedure, using the formulae of Chen and Werner et al. in the E = 0.2-2.0 keV energy range. The trial ...
2006-05-15
International Nuclear Information System (INIS)
Track analysis of medium energy #alpha# particle trajectories recorded in fine grain nuclear emulsion submitted to specific intensifying treatments led to the observation of strong ionizing events (SIE) sticking out of the primary's track core. Preliminary determinations showed that the number of SIEs increases with the primary's energy, and that their production is of more than one order of magnitude higher than the number of Rutherford recoils. The presence of SIEs on monoenergetic #alpha# tracks also has a significant influence on the measured range distribution, which, expressed in terms of energy loss, results in a mean contribution to the total energy loss of far reaching (SIEs (radial spread >= 0.458 #mu#m) of proportional 25 keV per 13.6 MeV #alpha# particle, instead of 0.75 keV in the case where only the Rutherford interactions are taken into account. Measurements carried out in detectors enriched with gelatin indicate an increase ...
International Nuclear Information System (INIS)
The neutron-capture cross sections of "1"6"8Yb, "1"8"0W, "1"8"4Os, "1"9"0Pt, and "1"9"6Hg have been measured by means of the activation technique. The samples were irradiated in a quasistellar neutron spectrum of kT=25 keV, which was produced at the Karlsruhe 3.7-MV Van de Graaff accelerator via the "7Li(p,n)"7Be reaction. Systematic uncertainties were investigated in repeated activations with different samples and by variation of the experimental parameters, that is, irradiation times, neutron fluxes, and #gamma#-ray counting conditions. The measured data were converted into Maxwellian-averaged cross sections at kT=30 keV, yielding 1214#+-#61, 624#+-#54, 590#+-#43, 511#+-#46, and 201#+-#11 mb for "1"6"8Yb, "1"8"0W, "1"8"4Os, "1"9"0Pt, and "1"9"6Hg, respectively. The present results either represent first experimental data ("1"6"8Yb, "1"8"4Os, and "1"9"6Hg) or could be determined with significantly reduced uncertainties ("1"8"0W and "1"9"0Pt). ...
2010-09-01
Energy Technology Data Exchange (ETDEWEB)
A large negative ion source for JT-60U produces high current ion beam from a wide extraction area of 45 cm x 110 cm. On the other hand, a cross-sectional area of the negative ion based neutral beam (NNB) injection port on JT-60U is narrow, about 50 cm x 60 cm. In order to inject the neutral beam at a high geometric efficiency, i.e. to suppress beam loss in the beamline, it is necessary to steer the beam for both compensation of undesirable beam deflection in extractor and focusing of the beam. For the JT-60U, two methods are provided for the required beam steering. Among them the results of beam steering experiment by aperture displacement and the design study are summarized in the present report. The experiment was carried out with 400 keV negative ion source, which has the three stage accelerator of similar structure as the JT-60U ion source, at Negative Ion Acceleration Test Stand (NIAS). High energy negative ion beams of the same perveance as that of 500 ...
2000-03-01
Energy Technology Data Exchange (ETDEWEB)
Silicon on insulator (SOI) structures are promising candidates for the fabrication of VLSI circuits with very high packing densities. The preparation of such structures can now be achieved by high dose implantation of reactive ion species such as oxygen to produce buried layers of SiO/sub 2/ in silicon. In this paper we report experiments to depth profile these layered structures by SIMS. SOI samples have been prepared by implanting (100) silicon wafers with 400 keV molecular oxygen ions at a dose of 1.8x10/sup 18/ O/sup +/ cm/sup -2/. During the implantation the wafers were maintained at temperatures between 325 and 600/sup 0/C, using beam heating, which achieved in situ-annealing and ensured that the top silicon layer remained single crystal. Analysis was carried out on an Atomika DIDA-II spectrometer using 10 keV Ar/sup +/ ions with a low current density of less than 1 mA cm/sup -2/. During analysis negative secondary ions were monitored ...
1983-12-15
Pulse power considerations for the generation of 45 #mu#s, 200 keV electron beams for CO_2 lasers
International Nuclear Information System (INIS)
A two module electron beam source operating over a wide range of output parameters has been designed and fabricated to be used in conjunction with a pair of electron beam sustained CO_2 lasers. Each module comprised a grid-controlled thermionic electron beam gun including a compact grid pulser for control of the electron beam, a 250 kV thyratron switched modulator for acceleration of the electron beam, a 1 kHz filament heater and a complex computerized control system. The system was designed to reliably produce 45 #mu#s wide electron pulses of 150-200 keV energy, operate at repetition rates of 1-10 pps and current densities of 5-20 mA/cm"2. Additional parameters are listed. The high voltage cathode assembly employs 132 thoriated tungsten filaments distributed over the area of the 250 cm x 10 cm output window. The cathode assembly including the control grids is supported by two high voltage ceramic bushings in a stainless steel vacuum chamber. For acceleration of ...
1989-01-19
Pitting and intergranular corrosion resistances of nitrogen ion implanted type 304 stainless steel
International Nuclear Information System (INIS)
Type 304 stainless steel (SS) specimens sensitised at 873 K and 973 K for 1, 10 and 100 hours respectively were ion implanted using a 150 keV accelerator at an energy of 70 keV in two different doses of nitrogen namely 1 x 10"1"6 to 1 x 10"1"7 ions/cm"2. Ion implantation at 1 x 10"1"6 ions/cm"2 did not show any improvement in pitting resistance, however, the specimens implanted at 1 x 10"1"7 ions/cm"2 showed significant increase in pitting corrosion resistance when potentiodynamic anodic polarisation studies were carried out in acidic chloride medium. For specimens aged at 873 K, nitrogen ion implantation at 1 x 10"1"6 ions/cm"2 increased the intergranular corrosion susceptibility compared to that of unimplanted specimens. However, at the dose of 1 x 10"1"7 ions/cm"2, insignificant IGC attack was noticed. The IGC resistance increased with increase in the dose for all the specimens aged at 973 K, and the reduction in the electrochemical ...
1998-05-24
Monte Carlo simulation and scatter correction of the GE Advance PET scanner with SimSET and Geant4
Energy Technology Data Exchange (ETDEWEB)
For Monte Carlo simulations to be used as an alternative solution to perform scatter correction, accurate modelling of the scanner as well as speed is paramount. General-purpose Monte Carlo packages (Geant4, EGS, MCNP) allow a detailed description of the scanner but are not efficient at simulating voxel-based geometries (patient images). On the other hand, dedicated codes (SimSET, PETSIM) will perform well for voxel-based objects but will be poor in their capacity of simulating complex geometries such as a PET scanner. The approach adopted in this work was to couple a dedicated code (SimSET) with a general-purpose package (Geant4) to have the efficiency of the former and the capabilities of the latter. The combined SimSET+Geant4 code (SimG4) was assessed on the GE Advance PET scanner and compared to the use of SimSET only. A better description of the resolution and sensitivity of the scanner and of the scatter fraction was obtained with SimG4. The accuracy of scatter correction ...
2005-10-21
Molecular dynamics studies of silicon ion implantation
Energy Technology Data Exchange (ETDEWEB)
Results are presented of molecular dynamics (MD) studies of 1-10 keV displacement cascades in silicon. At these energies, the simulations couple directly to experimental observations of low energy implantation in silicon for shallow junction formation. The simulations are performed with the Stillinger-Weber potential for silicon in computational cells with up to 3.5x10{sup 5} atoms. The author employs periodic boundary conditions in the [100] and [010] directions and a free surface on the top (001) plane. The author discusses the results in terms of the structural evolution and the dynamics of the cascade zones. For sufficiently high energy recoils (>2 KeV), the cascades produce locally molten zones that result in the formation of amorphous silicon pockets upon recrystallization. Frenkel pairs are also produced during the cascade, although their number is very small (less than 10% of the binary collision predictions). Upon annealing of the ...
1994-12-31
Microfabrication processes for high-T sub c superconducting films
Energy Technology Data Exchange (ETDEWEB)
Microfabrication processes for Y-Ba-Cu-O films have been investigated, using ion-beam techniques. High-{Tc} superconducting lines as narrow as 0.8 {mu}m have been fabricated from epitaxial YBa{sub 2}Cu{sub 3}O{sub 7 {minus} {ital y}} films by Ar ion-beam etching (IBE), combined with focused ion-beam (FIB) lithography. The resulting lines, 1.3 {mu}m wide and 2 mm long, showed a zero resistance temperature of 81 K and a critical current density of 1.9 {times} 10{sup 4} A/cm{sup 2} at 77.3 K. Maskless etching was carried out using 130-keV au{sup +} focused ion-beam (FIB) with a 0.1-{mu}m-diameter beam. A 50-nm-thick film was patterned into 0.3-{mu}m-wide lines at a dose of 5 {times} {sup 16} ions/cm{sup 2}. In comparison with Ar IBE, Cl{sub 2} reactive ion-beam etching (RIBE) exhibited an enhancement effect in sputtering yield. Ion implantation with 300-keV Si{sup + +} FIB also indicated the possibility to produce submicrometer patterns by ...
1989-12-01
Measurement of relative L X-ray intensity ratio following radioactive decay and photoionization
Energy Technology Data Exchange (ETDEWEB)
The measurements of the L X-ray intensity ratio I(L{alpha})/I(L{beta}), I(L{alpha})/I(L{gamma}), I(L{alpha})/I(L{iota}), I(L{beta})/I(L{gamma}) and I(L{iota})/I(L{gamma}) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a filtered radioisotope {sup 241}Am was used, and by the radioactive decay of {sup 160}Tb, {sup 160}Er, {sup 173}Lu, {sup 182}Re, {sup 201}Tl, {sup 203}Pb and {sup 207}Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L{alpha}/L{beta}), I(L{alpha}/L{gamma}), I(L{alpha}/L{iota}), I(L{beta}/L{gamma}) and I(L{iota}/L{gamma}) intensity ratios were calculated using theoretically tabulated values of subshell photoionization cross-section, fluorescence yield, fractional X-ray emission rates, ...
2008-05-22
Long pulse production of high current D"- ion beams in the JT-60 negative ion source
International Nuclear Information System (INIS)
The first long pulse production of high power D"- ion beams has been demonstrated in the JT-60 U negative ion sources, each of which was designed to produce 22 A, 500 keV D"- ion beams. Voltage holding capability and the grid power loading were examined for long pulse production of high power D"- ion beams. From the correlation between voltage holding and the light intensity of cathodoluminescence from the Fiber Reinforced Plastic insulators, the acceleration voltage for stable voltage holding capability was found to be less than 320-340 kV where the light was sufficiently suppressed. By tuning the extraction voltage, the grid power loadings in the ion sources were decreased to the allowable levels for long pulse injection without a significant reduction of the beam power. After tuning the acceleration and extraction voltages, D"- ion beams of 12.5 and 9.8 A were produced at 340 keV with cesium seeding at a rate of #approx#14 #mu#g/s into the ...
2008-02-01
Energy Technology Data Exchange (ETDEWEB)
'Improvement in understanding of the deposition of ambient dust particles on ECAM (Environmental Continuous Air Monitor) filters, reduction of the alpha-particle interference of radon progeny and other radioactive aerosols in different particle size ranges on filters, and development of ECAM''s with increased sensitivity under dusty outdoor conditions. As of May 1, 1998 (1/2 year into the project) the research-prototype 30-cm pulsed ionization chamber (PIC) is assembled and operational with an alpha particle energy resolution of better than 45 keV for 5-MeV alpha particles. Measurements of spectral resolution for alpha particles from radon decay products have been made as a function of filter type and dust loading conditions. So far, a study of ten filter types has found that the best combination of resolution and throughput is obtained with 3.0 \\265m Millipore fluoropore and 1.0 \\265m Corning FNMB filters. Experiments with gypsum and ...
1998-06-01
Investigation by XRF and XRD of Zn and Fe in Fe{sub x} Zn{sub 1-x} thin films
Energy Technology Data Exchange (ETDEWEB)
Fe{sub x}Zn{sub 1-x} alloys were electrochemically deposited on aluminum substrates from a sulfate bath. The K{beta}/K{alpha} x-ray intensity ratios of Zn and Fe in Fe{sub x}Zn{sub 1-x} thin films have been experimentally studied. The energy dispersive x-ray fluorescence (EDXRF) technique was used to measure K x-ray photons. Samples were excited by using 59.5 keV photons emitted by a 50 mCi {sup 241}Am radioactive source. The emitted K x-rays were detected by an Ultra-LEGe detector having a resolution of 150 eV at 5.9 keV. In addition, the effect of bath composition on the phase structure was investigated by x-ray diffraction (XRD) analysis. The composition of the thin films was analyzed by atomic absorption spectrometry analysis. Iron content was shown to strongly affect the structure of Zn-Fe alloys. It was found that the K-shell x-ray intensity ratio changed in Fe{sub x}Zn{sub 1-x} thin films for different values of x. The reason for this ...
2008-12-15
Investigation by XRF and XRD of Zn and Fe in Fex Zn1-x thin films
International Nuclear Information System (INIS)
FexZn1-x alloys were electrochemically deposited on aluminum substrates from a sulfate bath. The K?/K? x-ray intensity ratios of Zn and Fe in FexZn1-x thin films have been experimentally studied. The energy dispersive x-ray fluorescence (EDXRF) technique was used to measure K x-ray photons. Samples were excited by using 59.5 keV photons emitted by a 50 mCi 241Am radioactive source. The emitted K x-rays were detected by an Ultra-LEGe detector having a resolution of 150 eV at 5.9 keV. In addition, the effect of bath composition on the phase structure was investigated by x-ray diffraction (XRD) analysis. The composition of the thin films was analyzed by atomic absorption spectrometry analysis. Iron content was shown to strongly affect the structure of Zn-Fe alloys. It was found that the K-shell x-ray intensity ratio changed in FexZn1-x thin films for different values of x. The reason for this change may be that the electronegativity of iron is ...
2008-12-01
Defect engineering via ion implantation to control B diffusion in Si
International Nuclear Information System (INIS)
The processes which are currently studied in the fabrication of B-doped ultra shallow junctions (USJ) usually involve a preamorphization step to reduce B channelling effect during implantation and to improve B electrical activation. At this stage a high amount of Si interstitial atoms (Is), which dramatically increases the B diffusivity, is introduced. The introduction of voids in Si is a promising tool to control B transient enhanced diffusion (TED), because of their ability to capture Is. In this work the efficiency of a cavity band to reduce B TED is checked in silicon interstitial supersaturation conditions, obtained by high dose Si implantation. He is implanted either at 10 keV or at 50 keV with a fluence of 5 x 10"1"6 cm"-"2. Conventional techniques to introduce and activate the B (conventional ion implantation and rapid thermal annealing (RTA)) are applied in order to have a better control of the technological process to focus on the ...
2009-03-15
Comparison of enhanced device response and predicted x-ray dose enhancement effects on MOS oxides
Energy Technology Data Exchange (ETDEWEB)
The response of MOS capacitors to low- and medium-energy x-ray irradiation is investigated as a function of gate material (TaSi or Al), oxide thickness, and electric field. Measured device response is compared with predictions based on discrete ordinates and Monte Carlo code simulations of dose enhancement effects, coupled with recent estimates of electron-hole recombination in MOS oxides. In comparisons of 10-keV x-ray and Co-60 irradiations of Al-gate MOS capacitors at an oxide electric field of 1 MV/cm, it is found that predictions and experiments agree to within better than 20 percent for oxide thicknesses ranging from 35 to 1060 nm. For capacitors having TaSi/Al gates, predictions and experiments agree to within better than 30 percent at 1 MV/cm, with the largest differences occurring for 35-nm gate oxides. At other electric fields, the disagreement between experiment and prediction increases significantly for both Al- and TaSi/Al-gate capacitors, and can be ...
1988-12-01
Comparison of enhanced device response and predicted x-ray dose enhancement effects on MOS oxides
International Nuclear Information System (INIS)
The response of MOS capacitors to low- and medium-energy x-ray irradiation is investigated as a function of gate material (TaSi or Al), oxide thickness, and electric field. Measured device response is compared with predictions based on discrete ordinates and Monte Carlo code simulations of dose enhancement effects, coupled with recent estimates of electron-hole recombination in MOS oxides. In comparisons of 10-keV x-ray and Co-60 irradiations of Al-gate MOS capacitors at an oxide electric field of 1 MV/cm, it is found that predictions and experiments agree to within better than 20 percent for oxide thicknesses ranging from 35 to 1060 nm. For capacitors having TaSi/Al gates, predictions and experiments agree to within better than 30 percent at 1 MV/cm, with the largest differences occurring for 35-nm gate oxides. At other electric fields, the disagreement between experiment and prediction increases significantly for both Al- and TaSi/Al-gate capacitors, and can be ...
1988-07-12
Anode length optimization in a modified plasma focus device for optimal x-ray yields
International Nuclear Information System (INIS)
The effect of anode length and operating gas pressure on the x-ray emission from a nitrogen-filling modified plasma focus device has been investigated. The time-resolved investigation of x ray was carried out by using a five-channel photodiode x-ray spectrometer. The maximum x-ray yield is seen to increase with the increase in the anode length from 110 to 125 mm. Further increase in the anode length to 130 mm causes the x-ray yields to decrease. The highest x-ray yield of 4.5 J into 4#pi# sr was found for 125 mm anode length, which is 0.2% of the input energy. The average x-ray photon energy was estimated by using half-value thickness method and found to be 8.4 keV. The electron temperature of the plasma was estimated to be around 3 keV by x-ray intensity ratio method. The space-resolved x-ray-emitting zones for all the anodes were captured by a pinhole-based x-ray imaging camera and the images were scanned for different gray levels by using a ...
2006-01-01
Energy Technology Data Exchange (ETDEWEB)
In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the {sup 137}Cs-source with 10.4 GBq and {sup 60}Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form {sup 137} Cs 1173.23 and 1332.51 keV{sup 60} Co sources, and 14 peaks of {sup 134}Cs and {sup 154}Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show that the detection efficiency of gamma scanning system for 1 MeV ...
2003-10-01
International Nuclear Information System (INIS)
The development of a flat response small size, real time neutron dosimeter and ratemeter for the energy range of about 1 eV to 14 MeV is presented. This dosimeter is adequate for measuring neutron dose equivalents of 3 mRem up to 100 Rem and dose rates of 300 mRem/h to 50 Rem/h or more. The dosimeter consists of four Si surface barrier detectors. _1_0B radiators are placed in front of three of the detectors and a polyethylene radiator is placed in front of the fourth one. The _1_0B pellets are used for dose equivalent measurements in the energy range 1 eV to proportional1 MeV. The polyethylene radiator, made in two parts having thicknesses of 10 and 100 mg/cm_2 in an area ratio of 8 to 1, flattens the response to +-40% in the energy range 1-14 MeV. The signal-to-background ratio for different Si surface barrier detectors and for _1_0B polyethylene radiators was investigated. This dosimeter can give a rough estimation of the neutron spectrum by separating the total dose equivalent into ...
1983-06-01
/sup 242/Am/sup m/ fission cross section
Energy Technology Data Exchange (ETDEWEB)
The neutron-induced fission cross section of /sup 242/Am/sup m/ has been measured over the energy region from 10/sup -3/ eV to approx.20 MeV in a series of experiments utilizing a linac-produced ''white'' neutron source and a monoenergetic source of 14.1 MeV neutrons. The cross section was measured relative to that of /sup 235/U in the thermal (0.001 to approx.3 eV) and high energy (1 keV to approx.20 MeV) regions and normalized to the ENDF/B-V /sup 235/U(n,f) evaluated cross section. In the resonance energy region (0.5 eV to 10 keV) the neutron flux was measured using thin lithium glass scintillators and the relative cross section thus obtained was normalized to the thermal energy measurement. This procedure allowed a consistency check between the thermal and high energy data. The cross section data have a statistical accuracy of approx.0.5% at thermal energies and in the 1-MeV energy region, and a ...
1984-06-01
The Rio Grande alluvial floodplain aquifer between El Paso/Juarez and Fort Quitman, Texas has been intensively tilled and irrigated since 1910. Almost since that time, the Rio Grande and its interconnected alluvial aquifer in this stream reach have been affected by excessive salinity problems. Presently, salinity of surface water and groundwater increases from 800 to 2000 mg/L total dissolved solids (TDS) near El Paso, Texas to 2500 to 5500 mg/L TDS near Fort Quitman, Texas, approximately 115 km downstream. Chloride (Cl) and Chloride/Bromide (Cl/Br) ratios increase downstream, with a marked increase in salinity beginning about 45 km below El Paso. Groundwater sampling in an intensively investigated reach of the floodplain aquifer, extending from 35 to 60 km below El Paso identified two distinct water types. The first water type (17 samples) is a relatively dilute groundwater containing 1000 to 2000 mg/L TDS, 250 to 600 mg/L Cl, and Cl/Br weight ratios of 550 to 900. The second ...
2005-12-01
XPS study of passive films formed on molybdenum-implanted austenitic stainless steels
Energy Technology Data Exchange (ETDEWEB)
Austenitic stainless steels have been implanted with molybdenum ions (Mo[sup +], 100 keV, 2.5 x 10[sup 16] atoms cm[sup -2]). The implanted material has been characterized by XPS and RBS. The implanted region has a thickness of [approx] 1000 A with a maximum molybdenum concentration of [approx] 9 at.% Mo located at [approx] 210 A from the surface. The effects of implanted molybdenum on the passivation of the alloy in 0.5 M H[sub 2]SO[sub 4] have been investigated by electrochemistry and XPS. After XPS analysis the samples were transferred without exposure to air into a glove-box with an inert atmosphere. The electrochemical behaviour of the alloy is significantly modified by the implanted molybdenum. The major effect is that the activation peak disappears. A bilayer structure (outer hydroxide/inner oxide) of the passive film is observed for both the implanted and non-implanted alloys and the thicknesses of the films are similar. On the implanted alloy the outer ...
1992-06-01
XPS study of passive films formed on molybdenum-implanted austenitic stainless steels
International Nuclear Information System (INIS)
Austenitic stainless steels have been implanted with molybdenum ions (Mo"+, 100 keV, 2.5 x 10"1"6 atoms cm"-"2). The implanted material has been characterized by XPS and RBS. The implanted region has a thickness of #approx# 1000 A with a maximum molybdenum concentration of #approx# 9 at.% Mo located at #approx# 210 A from the surface. The effects of implanted molybdenum on the passivation of the alloy in 0.5 M H_2SO_4 have been investigated by electrochemistry and XPS. After XPS analysis the samples were transferred without exposure to air into a glove-box with an inert atmosphere. The electrochemical behaviour of the alloy is significantly modified by the implanted molybdenum. The major effect is that the activation peak disappears. A bilayer structure (outer hydroxide/inner oxide) of the passive film is observed for both the implanted and non-implanted alloys and the thicknesses of the films are similar. On the implanted alloy the outer hydroxide layer contains ...
1991-10-01
X-ray, Optical, and Radio Observations of SN 1999em and SN 1998S
Observations of the Type II-P (plateau) Supernova (SN) 1999em and Type IIn (narrow emission line) SN 1998S have enabled estimation of the profile of the SN ejecta, the structure of the circumstellar medium (CSM) established by the pre-SN stellar wind, and the nature of the shock interaction. SN 1999em is the first and only Type II-P detected at both X-ray and radio wavelengths. It is the least radio luminous and one of the least X-ray luminous SN ever detected (except for the unusual and very close SN 1987A). The Chandra X-ray data indicate non-radiative interaction of SN ejecta with a power-law density profile (rho \\propto r^{-n} with n ~ 7) with a pre-SN wind with a low mass loss rate of ~2 \\times 10^{-6} Msun/yr for a wind velocity of 10 km/sec, in close agreement with radio mass-loss rate estimates. The Chandra data show an unexpected, temporary rise in the 0.4--2.0 keV X-ray flux at ~100 days after explosion. SN 1998S appears reasonably typical of Type IIn ...
2001-01-01
X-ray production with sub-picosecond laser pulses
Energy Technology Data Exchange (ETDEWEB)
The interaction of intense, sub-picosecond laser pulses with solid targets produces intense picosecond x-ray pulses. With focused laser pulses of several 10 {sup 18} W/cm{sup 2}, He-like and H-like line radiation from targets such as aluminum and silicon has been produced. The energy conversion efficiency from the laser pulse energy to the 1--2 keV line x-rays is nearly one percent. The duration of the line x-ray radiation is of the order of ten picoseconds, although this may be an upper estimate because of the temporal resolution of the x-ray streak camera. The spatial extent of the x-ray source region is only slightly larger than the laser focal spot, or about 10 {mu}m in diameter. With these characteristics, such x-ray sources emit an intensity of nearly 10{sup 14} W/cm{sup 2}. Experiments and modeling which led to the above conclusions will be discussed.
1993-12-31
International Nuclear Information System (INIS)
We report the discovery of an active galactic nucleus (AGN) pair in the interacting galaxy system IRAS 20210+1121 at z = 0.056. An XMM-Newton observation reveals the presence of an obscured (N _H #approx# 5 x 10"2"3 cm"-"2), Seyfert-like (L _2_-_1_0_k_e_V = 4.7 x 10"4"2 erg s"-"1) nucleus in the northern galaxy, which lacks unambiguous optical AGN signatures. Our spectral analysis also provides strong evidence that the IR-luminous southern galaxy hosts a Type 2 quasar embedded in a bright starburst emission. In particular, the X-ray primary continuum from the nucleus appears totally depressed in the XMM-Newton band as expected in the case of a Compton-thick absorber, and only the emission produced by Compton scattering ('reflection') of the continuum from circumnuclear matter is seen. As such, IRAS 20210+1121 seems to provide an excellent opportunity to witness a key, early phase in the quasar evolution predicted by the theoretical models of quasar activation by ...
2010-10-20
Energy Technology Data Exchange (ETDEWEB)
Purpose: To evaluate micro computed tomography (micro-CT) for the assessment of osteochondritis dissecans in comparison with histology. Material and Methods: Osteochondritis dissecans lesions of 3 patients were evaluated using micro-CT (0.125 mA, 40 keV, 60 m slice thickness, 60 m isotropic resolution, entire sample) and light microscopy (toluidine blue, 3-5 m slice thickness). The methods were compared regarding preparation time, detectability of tissue types and morphologic features of bone and cartilage. Results: Non-destructive micro-CT imaging of the entire sample was faster than histologic preparation of a single slice for light microscopy. Morphologic features of bone and cartilage could be imaged in a comparable way to histology. It was not possible to image cells or different tissue types of bone and cartilage with micro-CT. Conclusion: Micro-CT is a fast, non-destructive tool that may be a supplement or, if detailed histologic information is not ...
2003-09-01
International Nuclear Information System (INIS)
Purpose: To evaluate micro computed tomography (micro-CT) for the assessment of osteochondritis dissecans in comparison with histology. Material and Methods: Osteochondritis dissecans lesions of 3 patients were evaluated using micro-CT (0.125 mA, 40 keV, 60 m slice thickness, 60 m isotropic resolution, entire sample) and light microscopy (toluidine blue, 3-5 m slice thickness). The methods were compared regarding preparation time, detectability of tissue types and morphologic features of bone and cartilage. Results: Non-destructive micro-CT imaging of the entire sample was faster than histologic preparation of a single slice for light microscopy. Morphologic features of bone and cartilage could be imaged in a comparable way to histology. It was not possible to image cells or different tissue types of bone and cartilage with micro-CT. Conclusion: Micro-CT is a fast, non-destructive tool that may be a supplement or, if detailed histologic information is not ...
2003-09-01
Kbeta-to-Kalpha X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of Ti(x)Ni(1-x) (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi (109)Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured Kbeta-to-Kalpha X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other element and/or the rearrangement of electrons between 3d and 4s, 4p states of ...
2010-01-28
International Nuclear Information System (INIS)
K?-to-K? X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of TixNi1-x (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi 109Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured K?-to-K? X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other element and/or the rearrangement of electrons between 3d and 4s, 4p states of individual metal atoms.
2010-06-01
Using Gamma-Ray Burst Prompt Emission to Probe Relativistic Shock Acceleration
It is widely accepted that the prompt transient signal in the 10 keV - 10 GeV band from gamma-ray bursts (GRBs) arises from multiple shocks internal to the ultra-relativistic expansion. The detailed understanding of the dissipation and accompanying acceleration at these shocks is a currently topical subject. This paper explores the relationship between GRB prompt emission spectra and the electron (or ion) acceleration properties at the relativistic shocks that pertain to GRB models. The focus is on the array of possible high-energy power-law indices in accelerated populations, highlighting how spectra above 1 MeV can probe the field obliquity in GRB internal shocks, and the character of hydromagnetic turbulence in their environs. It is emphasized that diffusive shock acceleration theory generates no canonical spectrum at relativistic MHD discontinuities. This diversity is commensurate with the significant range of spectral indices discerned in prompt burst ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
Prompt fission neutron spectrum measurements at the University of Massachusetts Lowell 5.5 MV Van de Graaff accelerator laboratory require that the neutron detector efficiency be well known over a neutron energy range of 100 keV to 20 MeV. The efficiency of the detector, has been determined for energies greater than 5.0 MeV using the Weapons Neutron Research (WNR) white neutron source at the Los Alamos Meson Physics Facility (LAMPF) in a pulsed beam, time-of-flight (TOF) experiment. Carbon matched polyethylene and graphite scatterers were used to obtain a hydrogen spectrum. The detector efficiency was determined using the well known H(n,n) scattering cross section. Results are compared to the detector efficiency calculation program SCINFUL available from the Radiation Shielding Information Center at Oak Ridge National Laboratory.
1994-06-01
Three-step photoionization of mercury for application to separation of mercury isomers
International Nuclear Information System (INIS)
Development of techniques for separating isomeric nuclides is important to the investigation of schemes for gamma-ray lasers. In preparation for an experiment to separate 10_1_4 atoms of the /sub 197m/Hg (299 keV, tau/sub 1/2/ = 24 hours) isomer, we report isotopically selective resonance ionization of mercury atoms. This has been accomplished by three-step excitation via the 6_3P"1 and 8_1S"0 excited states, using three collinear pulsed laser beams of 254, 286, and 532 nm wavelengths from a Nd:YAG and two dye lasers. These beams were passed through a closed mercury-vapor cell containing electrostatic plates to which the ions were drawn. Ion current and fluorescent radiation were measured as a function of laser frequency. Hyperfine structures for the 254- and 286-nm transitions were observed.
The peak to background method in quantitative ion microprobe analysis of thick biological specimens
Energy Technology Data Exchange (ETDEWEB)
The use of the ratio of the characteristic intensity to the continuum background intensity (P/B ratio) of the X-ray spectrum for a quantitative ion microprobe (IMP) or PIXE (particle induced X-ray emission) analysis of thin biological specimens was proposed previously. The IMP analysis of thick biological specimens is also of considerable practical use. In this paper, the possibility of using the P/B ratio to quantify minor elements in thick biological specimens is investigated. The epoxy resin based standards with gradual concentrations of KCNS up to 0.6 mol/kg and NBS bovine liver were analyzed by a 27 MeV {alpha} particle microprobe. The measured peak to background ratios (between 4.4 to 5.7 keV) agreed well with the theoretical calculations. The calculations showed that the concentration dependence of the P/B ratios was determined mainly by the absorption of X-rays in specimens. The results indicate that the P/B method is useful for IMP analysis of thick ...
1991-05-01
Energy Technology Data Exchange (ETDEWEB)
We proposed that a new type of the electrostatic microwiggler with a wiggler period (0.1 mm {le}1{sub w}{le}1 mm) and the wiggler field strength (E{sub w}{le} 100 kV/m) can be produced on the surface of a PZT when a high power and high frequency ultrasonic wave travels through a PZT bar. Numerical simulations in the linear and nonlinear gain regime show that a weak microwiggler (E{sub w}100 kV/m,{lambda}{sub w}{approx}100 periods), operating in magnetoresonance with a strong guide field (B{sub o}{approx} 3.6T), can generate a millimeter and submillimeter radiations with medium electronic efficiency of few percents. It is shown that the maximum output power of the compact FEL using the wiggler system generated on the surface of the piezoelectric material may be upto a few Watts with a relatively low energy and low current electron beam (Ew {approx}100 keV and I{sub b}1 mA).
1995-12-31
The intriguing nature of the high energy gamma ray source XSSJ12270-4859
The nature of the hard X-ray source XSSJ12270-4859 is still unclear though it was claimed to be a magnetic Cataclysmic Variable. We here present a broad-band X-ray and gamma ray study based on a recent XMM-Newton observation and archival INTEGRAL and RXTE data. From the Fermi/LAT 1-year point source catalogue, we tentatively associate XSSJ12270-4859 with 1FGLJ1227.9-4852, a source of high energy gamma rays with emission up to 10GeV. We complement the study with UV photometry from XMM-Newton and ground-based optical and near-IR photometry. The X-ray emission is highly variable showing flares and intensity dips. The X-ray flares consist of flare-dip pairs. Flares are also detected in the UV range but not the dips. Aperiodic dipping behaviour is also observed during X-ray quiescence but not in the UV. The 0.2-100keV spectrum is featureless and described by a power law model with Gamma=1.7. The 100MeV-10GeV spectrum is instead represented by a power law index of 2.45. ...
2010-01-01
We present a detailed spectral analysis of point-like X-ray sources in the XMM-COSMOS field. Our sample of 135 sources only includes those that have more than 100 net counts in the 0.3-10 keV energy band and have been identified through optical spectroscopy. The majority of the sources are well described by a simple power-law model with either no absorption (76%) or a significant intrinsic, absorbing column (20%).As expected, the distribution of intrinsic absorbing column densities is markedly different between AGN with or without broad optical emission lines. We find within our sample four Type-2 QSOs candidates (L_X > 10^44 erg/s, N_H > 10^22 cm^-2), with a spectral energy distribution well reproduced by a composite Seyfert-2 spectrum, that demonstrates the strength of the wide field XMM/COSMOS survey to detect these rare and underrepresented sources.
2006-01-01
British Library Electronic Table of Contents (United Kingdom)
The alloying of steel surface with aluminum (Al) using Microsecond-pulsed Intense Electron Beams (MIEB-Al) was developed and optimized in order to be used for improving the corrosion resistance of the 316, 1.4970 and T91 steels, exposed to liquid Pb and Pb-Bi-eutectic. The procedure consists in two steps: (i) coating the steel surface with Al or an Al-containing alloy layer and (ii) melting the coating layer and the steel surface layer using intense pulsed electron beam. In order to cover the steel surface with an homogeneous and crack-free Al-alloyed layer, the following experimental conditions are required: Al coating thickness range 5-10mm, electron kinetic energy 120keV; pulse duration 30ms; energy density 40-45J/cm2; number of pulses 2-3. Using the mentioned procedure, the corrosion r...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
With the aim of studying the magnetic properties of reduced-dimensionality magnetic systems we have patterned 250 nm- and 500 nm-size square elements on Fe/NiO layers by 30 keV Ga{sup +} focused ion beam (FIB) milling, varying beam current and pixel dwell time. By high resolution scanning electron microscope (SEM) imaging and atomic force microscopy (AFM) analysis we found that island size decreases from the nominal value by increasing the beam current and features sharpness improves on increasing the dwell time. The top surface of the isolated features has a pronounced edge bending which may be as high as 9 nm with respect to the flat inner area of the island and decreases as dwell time grows. By varying the ion fluence we found that such a shape is related to a surface swelling effect occurring at low ion fluence in the irradiated areas. The swelling-related damage at the edges is expected to influence the magnetic properties of the patterned features.
2005-04-01
International Nuclear Information System (INIS)
With the aim of studying the magnetic properties of reduced-dimensionality magnetic systems we have patterned 250 nm- and 500 nm-size square elements on Fe/NiO layers by 30 keV Ga"+ focused ion beam (FIB) milling, varying beam current and pixel dwell time. By high resolution scanning electron microscope (SEM) imaging and atomic force microscopy (AFM) analysis we found that island size decreases from the nominal value by increasing the beam current and features sharpness improves on increasing the dwell time. The top surface of the isolated features has a pronounced edge bending which may be as high as 9 nm with respect to the flat inner area of the island and decreases as dwell time grows. By varying the ion fluence we found that such a shape is related to a surface swelling effect occurring at low ion fluence in the irradiated areas. The swelling-related damage at the edges is expected to influence the magnetic properties of the patterned features.
2005-04-01
Study of iodine migration in zirconia using stable and radioactive ion implantation
Energy Technology Data Exchange (ETDEWEB)
The large uranium fission cross section leading to iodine and the behaviour of this element in the cladding tube during energy production and afterwards during waste storage is a crucial problem, especially for {sup 129}I which is a very long half-life isotope (T=1.59 x 10{sup 7} yr). Since a combined external and internal oxidation of the zircaloy cladding tube occurs during the reactor processing, iodine diffusion parameters in zirconia are needed. In order to obtain these data, stable iodine atoms were first introduced by ion implantation into zirconia with an energy of 200 keV and a dose equal to 8 x 10{sup 15} at cm{sup -2}. Diffusion profiles were measured using 3 MeV alpha-particle Rutherford backscattering spectrometry at each step of the annealing procedure between 700 C and 900 C. In such experiments a reduced iodine concentration was observed, which correlated to a diffusion-like process. Similar analysis has been performed using radioactive {sup 131}I ...
1998-03-01
International Nuclear Information System (INIS)
The nuclide "2"4"1Am decays by alpha emission to "2"3"7Np. Most of the decays (84.6%) populate the excited level of "2"3"7Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of "2"4"1Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.
2009-09-07
Spectroscopy of "8"8Sr with the "8"7Sr(n,#gamma#) and "8"7Sr(d,p) reactions
International Nuclear Information System (INIS)
The #gamma#-ray spectrum emitted after thermal neutron capture in "8"7Sr was studied at the ILL high flux reactor with pair- and intrinsic Ge-spectrometers. 661 transitions were assigned to the reaction "8"7Sr(n,#gamma#)"8"8Sr and 205 of them were placed into a "8"8Sr level scheme of 47 levels. This represents 88% of the observed intensity. The level energies were determined with a precision of better than 22 ppm; the neutron binding energy was determined as 11 112.69 (22) keV. To aid the analysis high resolution particle spectra of the reaction "8"7Sr(d,p)"8"8Sr were measured at 20 MeV deuteron energy with the Munich Q3D spectrometer. 85 states were observed with this reaction. The data helped to establish newly found levels and to differentiate between primary and secondary transitions in the (n,#gamma#) data. The observed level densities and primary transition strengths are compared with statistical model predictions and non-statistical effects are discussed. ...
Soft X-ray holography of FIB nanostructured Co/Pt multilayers
International Nuclear Information System (INIS)
Focused Ion Beam (FIB) milling is a powerful tool to produce ordered magnetic nanostructures. However, it is impossible to produce out-of-plane magnetized nanoscale structures from multilayer films by direct FIB writing. Co/Pt multilayers exhibit an out-of-plane easy axis due to strong perpendicular interface anisotropy. The interface contribution is known to be very sensitive to high energy ion irradiation. In case of 30 keV Ga ions it needs less than one ion per 100 surface atoms to destroy the perpendicular interface anisotropy. We demonstrate how this problem can be overcome by milling a Co/Pt multilayer, which has been deposited on a SiN membrane, from the rear side, through the SiN. The effect of the ions is determined as a function of applied dose utilizing the domain structure imaged by soft X-ray holography. When the magnetic material is removed we find only a very narrow range of destruction around the holes in contrast to the observations when milling ...
2009-03-22
Radioanalytical determination of chromium in welding fumes
International Nuclear Information System (INIS)
Radionuclide X-ray fluorescence analysis and fast neutron activation analysis were used for the determination of chromium. The excitation source for X-ray fluorescence analysis was a ring-shaped "2"4"1Am source with an activity of 18.5x10"9 Bq. SYNPOR filters of 35 mm in diameter were used for the measurement. The 5.414 keV Cr peak was measured with a Si(Li) detector. The sensitivity was 0.05 mg for a period of measurement of 1000 s. A neutron generator with an emission of 10"9 s"-"1 was used as the source of fast neutrons. "5"2V and "5"3V, the products of nuclear reaction with Cr, were measured gamma spectrometrically with a Ge(Li) detector. The sensitivity for Cr is 0.015 mg, in the presence of Mn which causes interference the sensitivity is a mere 0.075 mg. The mentioned methods were used to determine total Cr and Cr(VI) in welding aerosols. It was found that the most toxic form, i.e., Cr(VI), is released during manual arc welding of high alloy steels with ...
1985-01-01
High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics was used to characterize the pulse rise time of deposited gamma photons. Time ...
2000-01-01
Production of atomic negative ion beams of the Group IA elements
Energy Technology Data Exchange (ETDEWEB)
A method has been developed which enables the direct sputter generation of atomic negative ion beams of all members of the Group IA elements (Li, Na, K, Rb, and Cs). The method consists of the use of sputter samples formed by pressing mixtures of the carbonates of the Group IA elements and 10% (atomic) Cu, Ag, or other metal powder. The following intensities are typical of those observed from carbonate samples subjected to /approximately/3 KeV cesium ion bombardment: Li/sup -/: greater than or equal to0.5 ..mu..A; Na/sup -/: greater than or equal to0.5 ..mu..A; K/sup -/: greater than or equal to0.5 ..mu..A; Rb/sup -/: greater than or equal to0.5 ..mu..A; Cs/sup -/: greater than or equal to0.2 ..mu..A. 7 refs., 2 figs., 1 tab.
1988-01-01
Performance testing of selected types of electronic personal dosimeters used in Sudan
International Nuclear Information System (INIS)
Measurements were carried out for calibration and performance testing of a set of 10 electronic personal dosimeters (EPDs) at the Secondary Standard Dosimetry Laboratory of Sudan. Calibrations were carried out at three X-ray beam qualities described in ISO standard 4037 in addition to 137Cs and 60Co gamma ray beams. The experimental was performed with EPDs mounted on ICRU Slab phantom. X-ray and ?-ray beams were characterized in terms of air kerma free-in-air which were converted to the known delivered personal dose equivalent, Hp(10) using appropriate the air kerma to personal dose equivalent conversion coefficients. Dosimeters tested showed excellent energy and angular response and relative error of indication within the recommended limit for photon energies from 65 keV to 1.25 MeV. The study showed encouraging results for using electronic dosimeters in personal dosimetry.
2010-12-01
Performance of Alcator C-Mod core Thomson scattering system
Energy Technology Data Exchange (ETDEWEB)
Design of the Alcator C-Mod Thomson scattering (TS) diagnostic is discussed and the results of the measurements are presented. The TS system has six spatial channels with observation volumes evenly distributed between the midplane and the edge of the plasma. Each channel is capable of measuring the electron density in the range N{sub e}=5{times}10{sup 19}{endash}5{times}10{sup 21} m{sup {minus}3} and temperature from T{sub e}=200 eV to 10 keV. A 30 Hz, 1.5 J per pulse Nd-YAG laser is employed allowing the measurements of evolution of T{sub e} and N{sub e} profiles during plasma shot. A laser beam position control and feedback system provides for the beam alignment stability and reliable electron density measurements. Examples of the core density and temperature profiles measured at different stages of the plasma evolution are discussed. {copyright} {ital 1999 American Institute of Physics.}
1999-01-01
New high-spin isomer and quasiparticle-vibration coupling in "1"8"7Ir
International Nuclear Information System (INIS)
The high-spin structure of the Z=77 nucleus "1"8"7Ir has been studied using the fusion-evaporation reaction "1"8"6W("7Li6n) at a beam energy of 59 MeV. The excitation scheme of this nucleus has been extended by more than 110 new states, including extensions of all previously established rotational bands. The band crossing region of the h_9_/_2 negative-parity yrast band has been revised and new intrinsic high-K states have been identified. In particular, a 29/2"- isomeric state [T_1_/_2=1.8(5)#mu#s] at an excitation energy of 2487 keV has been observed for the first time, and on top of it, a rich level scheme reaching up to spin (59/2"-) and excitation energies around 7 MeV has been established.
2010-05-01
Neutrino emission in neutron matter from magnetic moment interactions
Neutrino emission drives neutron star cooling for the first several hundreds of years after its birth. Given the low energy ($\\sim$ keV) nature of this process, one expects very few nonstandard particle physics contributions which could affect this rate. Requiring that any new physics contributions involve light degrees of freedom, one of the likely candidates which can affect the cooling process would be a nonzero magnetic moment for the neutrino. To illustrate, we compute the emission rate for neutrino pair bremsstrahlung in neutron-neutron scattering through photon-neutrino magnetic moment coupling. We also present analogous differential rates for neutrino scattering off nucleons and electrons that determine neutrino opacities in supernovae. Employing current upper bounds from collider experiments on the tau magnetic moment, we find that the neutrino emission rate can exceed the rate through neutral current electroweak interaction by a factor two, signalling ...
2004-01-01
Molar extinction coefficients of some fatty acids
International Nuclear Information System (INIS)
The attenuation of gamma rays in some fatty acids, viz. formic acid (CH_2O_2), acetic acid (C_2H_4O_2), propionic acid (C_3H_6O_2), butyric acid (C_4H_8O_2), n-hexanoic acid (C_6H_1_2O_2), n-caprylic acid (C_8H_1_6O_2), lauric acid (C_1_2H_2_4O_2), myristic acid (C_1_4H_2_8O_2), palmitic acid (C_1_6H_3_2O_2), oleic acid (C_1_8H_3_4O_2) and stearic acid (C_1_8H_3_6O_2), has been measured at the photon energies 81, 356, 511, 662, 1173 and 1332 keV. Experimental values for the molar extinction coefficient, the effective atomic number and the electron density have been derived and compared with theoretical calculations. There is good agreement between experiment and theory.
2002-10-01
Molar extinction coefficients of some commonly used solvents
International Nuclear Information System (INIS)
Molar extinction coefficients of some commonly used solvents (ethanol (C_2H_5OH), methanol (CH_3OH), propanol (C_3H_7OH), butanol (C_4H_9OH), water (H_2O), toluene (C_7H_8), benzene (C_6H_6), carbontetrachloride (CCl_4), acetonitrile (C_4H_3N), chlorobenzene (C_6H_5Cl), diethylether (C_4H_1O) and dioxane (C_4H_8O_2)) have been determined by a well-collimated narrow beam transmission geometry at 279, 356, 662, 1173, 1252 and 1332 keV #gamma# rays. The total #gamma# ray interaction cross sections of these solvents have also been determined. A good agreement has been obtained between the experimental results with the theoretical values evaluated through XCOM calculations.
2006-07-01
Molar extinction coefficients of some carbohydrates in aqueous solutions
Molar extinction coefficients of some carbohydrates viz. L-arabinose (C5H10O5), D-glucose (C6H12O6), D-mannose (C6H12O6), D-galactose (C6H12O6), D(-) fructose (C6H12O6) and maltose (C12H24O12) in aqueous solutions have been determined at 81, 356, 511, 662, 1173 and 1332 keV by gamma ray transmission method in a narrow beam good geometry set-up. These coefficients have been found to depend upon the photon energy following a 4-parameter polynomial. These extinction coefficients for different sugars having the same molecular formula have same values varying within experimental uncertainty. Within concentration ranges studied, Beer--Lambert law is obeyed very well.
2002-03-01
Molar extinction coefficients in aqueous solutions of some amino acids
International Nuclear Information System (INIS)
Mass attenuation coefficients of amino acids viz. glycerine (C_2H_5NO_2), 1-Serine (C_3H_7NO_3), 1-Theronine (C_4H_9NO_3), 1-Proline (C_5H_9NO_2), 1-Valine (C_5H_1_1NO_2) and 1-Phenylalanine (C_9H_1_1NO_2) in aqueous solutions have been determined at 81, 356, 511, 662, 1173 and 1332 keV by the gamma-ray transmission method in a narrow beam good geometry setup. Precisely measured densities of these solutions were used for the determination of these coefficients which varied systematically with the corresponding changes in the concentrations (g/cm"3) of the solutions. Molar extinction coefficients of amino acids were then obtained at these energies and were found to be in good agreement with the theoretical results. In addition, total interaction cross sections of amino acids in aqueous solutions were also calculated. (author)
2002-09-01
Microstructural observation of focused ion beam modification of Ni silicides/Si thin films
International Nuclear Information System (INIS)
Focused ion beam (FIB) irradiation of a thin Ni_2Si layer deposited on a Si substrate was carried out and studied using an in-situ transmission electron microscope (in-situ TEM). Square areas on sides of 4 by 4 and 9 by 9 microm were patterned at room temperature with a 25 keV Ga"+-FIB attached to the TEM. The structural changes of the films indicate a uniform milling, sputtering of the Ni_2Si layer and the damage introducing to the Si substrate. Annealing at 673 K results in the change of the Ni_2Si layer into an epitaxial NiSi_2 layer outside the FIB irradiated area, but several precipitates appear around the treated area. Precipitates was analyzed by energy dispersive X-ray spectroscopy (EDS). Larger amount of Ni than the surrounding matrix was found in precipitates. Selected area diffraction (SAD) patterns of the precipitates and the corresponding dark field images imply the formation of a Ni rich silicide. The relation between the FIB tail and the ...
1996-12-02
Micro and nano patterning by focused ion beam enhanced adhesion
International Nuclear Information System (INIS)
We report a new method of generating nano and micro patterns using focused ion beam (FIB) induced adhesion. The method utilizes selective irradiation of thin metallic films grown on substrates by focused ion beam followed by peel off. After peel off of the irradiated thin film it is observed that the ion beam scanned portions are retained on the substrate, creating nano and micro patterns. The method is suitable for materials of which the adhesion to the substrate can be improved by ion bombardment. The phenomenon has been demonstrated by creating gold nano patterns of different shapes and sizes ranging from 500 nm to 5 #mu#m on SiO_2-Si substrate using 10-30 keV Ga FIB at beam currents up to 10 pA. The mechanism involved in the process has been discussed. The technique could be utilized to prepare micro and nano patterns of thin films deposited on an appropriate substrate for optical, plasmonic and sensor related applications.
2009-05-01
Measurement of gamma-ray detection efficiency in irradiated materials examination facility
Energy Technology Data Exchange (ETDEWEB)
The detection efficiency of gamma scanning system in irradiated materials examination facility has been measured. Gamma-ray sources used in this experiment are Cs-Co standard sources a PWR spent fuel rod in which {sup 134}Cs and {sup 154}Eu peaks are clearly identified in the energy region of 500 to 1,600 keV. The distance between source and detector is about 1.6 m. A slit type collimator with 3 mm-width window and 30 mm-thick lead block are installed between source and detector. The detector is a HPGe detector. This equipment is mainly used in gamma scanning of irradiated nuclear fuel. The measured detection efficiency seems to be 1.89 x 10{sup -6} % for 1 MeV gamma-ray. With these results the activities of unknown sources could be measured. This results are expected to be used in the measurement of the absolute distribution of gamma emitting nuclides in nuclear fuel.
2001-05-01
Measurement of $\\phi$(1020) meson leptonic width with CMD-2 detector at VEPP-2M Collider
The $\\phi$(1020) meson leptonic width has been determined from the combined analysis of 4 major decay modes of the resonance ($\\phi\\to K^+ K^-,K^0_LK^0_S,\\pi^+\\pi^-\\pi^0,\\eta\\gamma$) studied with the CMD-2 detector at the VEPP-2M $e^+e^-$ collider. The following value has been obtained: $\\Gamma(\\phi\\to e^+e^-) = 1.235\\pm 0.006\\pm 0.022$ keV. The $\\phi(1020)$ meson parameters in four main decay channels have been also recalculated: $B(\\phi\\to K^+K^-) = 0.493\\pm 0.003\\pm 0.007$, $B(\\phi\\to K_LK_S) = 0.336\\pm 0.002\\pm 0.006$, $B(\\phi\\to\\pi^+\\pi^-\\pi^0) = 0.155\\pm 0.002\\pm 0.005$, $B(\\phi\\to\\eta\\gamma) = 0.0138\\pm 0.0002\\pm 0.0002$.
2010-01-01
Measurement of "1"0"1Tc Half-Life
International Nuclear Information System (INIS)
75 mg (NH_4)_6Mo_7O_24 #centre dot# 4H_2O solution was irradiated for 20 min in miniature neutron source reactor (MNSR) and cooled for 12 min. In the conditions of 0.8 mol/L HNO_3, phase ratio 1:1, the solution of "1"0"1Tc sample was extracted twice with #alpha#-benzoin oxime/ethyl acetate phase to remove "1"0"1Mo and a radiochemically pure and carrier-free "1"0"1Tc product was obtained. The half-life of "1"0"1Tc was accurately measured with a HPGe #gamma#-detector by following 306.8 keV #gamma#-ray about 150 min, and processed the data by three methods, R-value method, iterative method and translation method. Five parallel measurments gave a half-life (14.02 #+-# 0.01) min (n=5) for "1"0"1Tc. (authors)
2009-11-01
M X-ray production in Nd, Gd, Ho and Lu by 1-6 MeV lithium ions
Energy Technology Data Exchange (ETDEWEB)
M-shell X-rays of the rare-earth elements {sub 60}Nd, {sub 64}Gd, {sub 67}Ho and {sub 71}Lu were measured for lithium ion bombardment in the energy range 1.0-6.0 MeV. The M-shell X-rays with energies of 0.978-1.631 keV were detected with a LINK analytical detector. The efficiency of the detector was determined by using the known atomic-field bremsstrahlung cross-sections from low energy electron beams and K-shell X-ray measurements with light projectiles. The measured cross-sections are compared to the predictions of the first Born approximation and the ECPSSR (energy loss and Coulomb deflection effects, perturbed stationary state approximation with relativistic correction) theories. The best theoretical description of the present data is given by the ECPSSR theory, even though the discrepancy between data and theory is increasing at higher projectile energies.
2004-06-01
Low-energy measurements of electron capture by multicharged ions from excited hydrogen atoms
International Nuclear Information System (INIS)
For very low collision energies electron capture from excited hydrogen by multicharged ions is characterized by enormous cross sections, the predicted maximum being comparable to the geometric size of the Rydberg atom. The ion-atom merged-beams technique is being used to study these collisions for the variety of charge states and the wide range of energies (0.1 to 1000 eV/amu) accessible to the apparatus. A neutral D beam containing a Rydberg atom population proportional to 1/n"3 is produced by collisional electron detachment of 8 keV D"- in N_2 gas. An applied electric field results in the range (n=24--11) depending on the strength of the field applied. This beam is then merged with O"3"+ or O"5"+ ion beams at low relative collision velocities where the resultant beam-beam signal of D"+ due to electron loss is dominated by electron capture. From the sharp decrease in the observed beam-beam signal as the electric field increases it is inferred that the electron ...
Energy Technology Data Exchange (ETDEWEB)
Excellent silicided shallow p{sup +}n junctions have been successfully achieved by the implantation of BF{sub 2}{sup +} ions into thin Pd{sub 2}Si films on Si substrates to a dose of 5 {times} 10{sup 15} cm{sup {minus}2} and subsequent low temperature (even at 550 C) furnace annealing. The formed junctions have been characterized for respective implantation conditions. In this experiment, the implant energy is the key role in obtaining a low leakage diode. Reverse current density of about 3 nA/cm{sup 2} and an ideality factor of about 1.05 can be attained by the implantation of BF{sub 2}{sup +} ions at 80 keV and subsequent annealing at 550 C. The junction depth is about 0.09 {mu}m, measured by the spread resistance method. As compared with the results of unimplanted specimens, the implantation of BF{sub 2}{sup +} ions into a thin Pd{sub 2}Si layer can stabilize the silicide film and prevent it from forming islands during high temperature annealing.
1995-05-01
Energy Technology Data Exchange (ETDEWEB)
An attempt was made to minimize the channeling tail by implantation along a random equivalent direction following a careful alignment of the target. In order to analytically determine the random equivalent directions, critical angles for channeling were mapped on a stereogram. Boron ions with energies of 17 and 45 keV are implanted along specified directions determined from the map. The depth distribution of the dopant is profiled by SIMS and the effects of water orientation upon the channeling tail are noted. Industrial common use of a 7/sup 0/ tilt is not optimum. However, implantation with the wafer tilted at 5.5 +/- 0.5/sup 0/ from the surface normal and rotated at 7.0 +/- 0.5/sup 0/ from a (100) plane shows the least channel-tail compared to implantation along other directions. Rapid thermal annealing (RTA) is a promising annealing method for shallow junction formation. Transient enhanced diffusion of implanted boron is observed. Two different mechanisms for ...
1985-01-01
International Nuclear Information System (INIS)
An attempt was made to minimize the channeling tail by implantation along a random equivalent direction following a careful alignment of the target. In order to analytically determine the random equivalent directions, critical angles for channeling were mapped on a stereogram. Boron ions with energies of 17 and 45 keV are implanted along specified directions determined from the map. The depth distribution of the dopant is profiled by SIMS and the effects of water orientation upon the channeling tail are noted. Industrial common use of a 7"0 tilt is not optimum. However, implantation with the wafer tilted at 5.5 +/- 0.5"0 from the surface normal and rotated at 7.0 +/- 0.5"0 from a (100) plane shows the least channel-tail compared to implantation along other directions. Rapid thermal annealing (RTA) is a promising annealing method for shallow junction formation. Transient enhanced diffusion of implanted boron is observed. Two different mechanisms for the boron ...
Lifetime and {ital g}-factor measurements of the 11{sup {minus}} isomer in {sup 92}Tc
Energy Technology Data Exchange (ETDEWEB)
The half-life ({ital T}{sub 1/2}) and {ital g} factor of the 2002 keV 11{sup {minus}} isomer in the odd-odd nucleus {sup 92}Tc produced by the pulsed heavy-ion reaction {sup 68}Zn({sup 28}Si,{ital p}3{ital n}){sup 92}Tc have been measured using time differential perturbed angular distribution method. The measured {ital T}{sub 1/2} value is 3.15(20) ns. From the observed spin precession frequency {omega}{sub {ital L}} of a {sup 92}Tc recoil implanted into a ferromagnetic Ni host, we obtain the {ital g} factor to be 0.806(20). The measured value of the {ital g} factor is in good agreement with a shell model analysis carried out using {pi}({ital p}{sub 1/2}{ital g}{sub 9/2}) and {nu}({ital p}{sub 1/2}{ital g}{sub 9/2}) orbitals for the proton particles and neutron holes outside the {sup 88}Sr core. {copyright} {ital 1996 The American Physical Society.}
1996-12-01
Large area, low capacitance Si(Li) detectors for high rate x-ray applications
Energy Technology Data Exchange (ETDEWEB)
Large area, single-element Si(Li) detectors have been fabricated using a novel geometry which yields detectors with reduced capacitance and hence reduced noise at short amplifier pulse-processing times. A typical device employing the new geometry with a thickness of 6 mm and an active area of 175 mm 2 has a capacitance of only 0.5 pf, compared to 2.9 pf for a conventional planar device with equivalent dimensions. These new low capacitance detectors, used in conjunction with low capacitance field effect transistors, will result in x-ray spectrometers capable of operating at very high count rates while still maintaining excellent energy resolution. The spectral response of the low capacitance detectors to a wide range of x-ray energies at 80 K is comparable to typical state-of-the-art conventional Si(Li) devices. In addition to their low capacitance, the new devices offer other advantages over conventional detectors. Detector fabrication procedures, I-V and C-V characteristics, noise ...
1992-10-01
Energy Technology Data Exchange (ETDEWEB)
K{beta}-to-K{alpha} X-ray intensity ratios of Ti, V, Cr, and Co in pure metals and their disilicide compounds have been measured following excitation by 59.54 keV {gamma}-rays from a 200 mCi {sup 241}Am point-source. The K{beta}-to-K{alpha} intensity ratios of all these metals in the disilicide compounds are found to be less than the corresponding ratios for pure metals. Comparison of the measured K{beta}-to-K{alpha} intensity ratios for the disilicides and pure metals with the multiconfiguration Dirac-Fock calculations indicates increase of the 3d electron populations of Ti, V, Cr, and Co in the disilicides from their pure metal values suggesting the rearrangement of electrons between 3d and 4s states of the individual metal atom. This rearrangement is found to be opposite to that observed in our previously reported work on NiSi{sub 2} and CuSi{sub 2}.
1999-06-01
Kinetic Monte Carlo (KMC) simulations for boron diffusion in ion-implanted crystalline materials
Energy Technology Data Exchange (ETDEWEB)
In this paper, we report kinetic Monte Carlo study on the diffusion behavior of boron in silicon crystal, more particularly on the transient enhanced diffusion (TED) of boron in silicon during implantation and annealing. Firstly, the accuracy of our KMC code was verified by investigating the time evolutionary behavior of interstitial (I) and vacancy (V) when a silicon substrate is implanted with silicon dose with an energy of 10 keV and with a dose of 1 X 10{sup 14} ions/cm{sup 2}. To investigate the influence of native defects (I, V) on boron diffusion, a single and multi boron markers grown by MBE were employed. The simulation results revealed that the precursor of boron cluster (BI{sub 2}) is dominant at the initial stage of annealing, which explains the boron TED phenomenon in terms of the concentration of boron complexes and I, V clusters, respectively. The formation of {l_brace}311{r_brace} defects and dislocation loop were observed from the time-evolutionary ...
2004-11-15
Kinetic Monte Carlo (KMC) simulations for boron diffusion in ion-implanted crystalline materials
International Nuclear Information System (INIS)
In this paper, we report kinetic Monte Carlo study on the diffusion behavior of boron in silicon crystal, more particularly on the transient enhanced diffusion (TED) of boron in silicon during implantation and annealing. Firstly, the accuracy of our KMC code was verified by investigating the time evolutionary behavior of interstitial (I) and vacancy (V) when a silicon substrate is implanted with silicon dose with an energy of 10 keV and with a dose of 1 X 10"1"4 ions/cm"2. To investigate the influence of native defects (I, V) on boron diffusion, a single and multi boron markers grown by MBE were employed. The simulation results revealed that the precursor of boron cluster (BI_2) is dominant at the initial stage of annealing, which explains the boron TED phenomenon in terms of the concentration of boron complexes and I, V clusters, respectively. The formation of #left brace#311#right brace# defects and dislocation loop were observed from the time-evolutionary study ...
2004-11-01
International Nuclear Information System (INIS)
K#beta#-to-K#alpha# X-ray intensity ratios of Ti, V, Cr, and Co in pure metals and their disilicide compounds have been measured following excitation by 59.54 keV #gamma#-rays from a 200 mCi "2"4"1Am point-source. The K#beta#-to-K#alpha# intensity ratios of all these metals in the disilicide compounds are found to be less than the corresponding ratios for pure metals. Comparison of the measured K#beta#-to-K#alpha# intensity ratios for the disilicides and pure metals with the multiconfiguration Dirac-Fock calculations indicates increase of the 3d electron populations of Ti, V, Cr, and Co in the disilicides from their pure metal values suggesting the rearrangement of electrons between 3d and 4s states of the individual metal atom. This rearrangement is found to be opposite to that observed in our previously reported work on NiSi_2 and CuSi_2.
1999-06-01
Iridium and PGE in sedimentary rocks; Iridium et platinoides dans les roches sedimentaires
Energy Technology Data Exchange (ETDEWEB)
The detection limit of Instrumental Neutron Activation Analysis (INAA), about a few microgram per kg, is not sufficient to determine iridium concentrations in most geological samples. Use of the coincidence counting of the 316 and 468 keV gamma-rays emitted during the decay of {sup 192}Ir, improved the sensitivity (0.01 microgram per kg). The high iridium content of the clay layers from the Cretaceous-Tertiary transition (KTB) has been considered as an evidence of the extra-terrestrial origin of the KTB mass extinction. However some results indicate that a significant part of the iridium content in sediments has a volcanic origin. Radiochemical Neutron Activation Analysis (RNAA) in some KTB samples and in basic and ultra-basic rocks show that, unlike in volcanic products, no PGE (platinoids) fractionation appears in KTB samples. The nearby chondritic PGE pattern supports an extra-terrestrial origin for the KTB iridium anomaly. 2 figs., 2 tabs., 37 refs.
1994-12-31
Investigation of natural radionuclides in selected NORM-samples
International Nuclear Information System (INIS)
A programme has been initiated by the Coordinating Office for Monitoring of enhanced natural radioactivity of the Federal Office for Radiation Protection to investigate different kinds of sample materials with enhanced naturally occurring radioactivity (NORM) such as scales from oilfield and naturally gasfield pipes, blast furnace sludge and sinter dust from the production of pig iron, as well as bauxit and red mud from the production of aluminium oxide. The aim of these investigations is to find proper preparation and measuring methods which allow, in particular, a sample treatment with optimised effort combined with a reliable determination of the specific activities of the dominating radionuclides. Of particular interest is the method of gamma-ray spectrometry, since this method has been used for most of our studies of sample materials. Due to different compositions of calibration and NORM-samples, e.g. different densities, and the analysis of low-energy gamma-rays such as the 46.54 ...
2005-09-20
Interactions of ion-implantation-induced interstitials with boron at high concentrations in silicon
Energy Technology Data Exchange (ETDEWEB)
Ion implantation of Si (60 keV, 1{times}10{sup 14}/cm{sup 2}) has been used to introduce excess interstitials into silicon predoped with high background concentrations of B, which were varied between 1{times}10{sup 18} and 1{times}10{sup 19}/cm{sup 3}. Following post-implantation annealing at 740{degree}C for 15 min to allow agglomeration of the available interstitials into elongated {l_brace}311{r_brace} defects, the density of the agglomerated interstitials was determined by plan-view transmission electron microscopy observation of the defects. We report a significant reduction in the fraction of excess interstitials trapped in {l_brace}311{r_brace} defects as a function of boron concentration, up to nearly complete disappearance of the {l_brace}311{r_brace} defects at boron concentrations of 1{times}10{sup 19}/cm{sup 3}. The reduction of the excess interstitial concentration is interpreted in terms of boron-interstitial clustering, and implications for ...
1996-09-01
Interactions of ion-implantation-induced interstitials with boron at high concentrations in silicon
International Nuclear Information System (INIS)
Ion implantation of Si (60 keV, 1x10"1"4/cm"2) has been used to introduce excess interstitials into silicon predoped with high background concentrations of B, which were varied between 1x10"1"8 and 1x10"1"9/cm"3. Following post-implantation annealing at 740 degree C for 15 min to allow agglomeration of the available interstitials into elongated #left brace#311#right brace# defects, the density of the agglomerated interstitials was determined by plan-view transmission electron microscopy observation of the defects. We report a significant reduction in the fraction of excess interstitials trapped in #left brace#311#right brace# defects as a function of boron concentration, up to nearly complete disappearance of the #left brace#311#right brace# defects at boron concentrations of 1x10"1"9/cm"3. The reduction of the excess interstitial concentration is interpreted in terms of boron-interstitial clustering, and implications for transient-enhanced diffusion of B at high ...
Energy Technology Data Exchange (ETDEWEB)
We have simulated the transient enhanced diffusion (TED) of boron fluoride (BF{sub 2}{sup +}) implanted in crystalline and germanium amorphized silicon. Based on recently published models, the effect of fluorine on boron diffusion in silicon has been introduced and a modelling has been suggested. In order to simulate the boron experimental profiles, we have assumed that fluorine forms clusters involving interstitial boron which reduces the junction depth. Experimental results indicate that fluorine behaviour depends on amorphization energy. Moreover, even no germanium preamorphization is performed, silicon is still amorphized by fluorine species. Hence, BF{sub 2}{sup +} implantation leads to an amorphous/crystalline (a/c) interface near the surface. An improvement of published models is suggested taking into account fluorine effects. The simulations satisfactory reproduce the SIMS experimental profiles for a large scale of experimental conditions.
2002-01-01
International Nuclear Information System (INIS)
The inelastic energy losses for single collisions of Xe"+ ions with Xe targets have been measured for incident ion energies from 0.3 to 1.2 MeV and for scattering angles from 3"0 to 20"0. The energy losses were found to range from 1 to 11 keV with distinct steps at distances of closest approach of 0.22 and 0.12 A. By comparing these data with earlier ionization data by the same authors these steps are shown to be caused by M-shell excitation. Other excitations observed in the ionization data may be attributed to N-shell excitation. The distances of closest approach at which these excitations occur agree well with calculations by Eichler and Wille and co-workers, giving further evidence of the usefulness of Fano and Lichten's one-electron molecular model and these calculations.
High variability in Vela X-1: giant flares and off states
We investigate the spectral and temporal behavior of the high mass X-ray binary Vela X-1 during a phase of high activity, with special focus on the observed giant flares and off states. INTEGRAL observed Vela X-1 in a long almost uninterrupted observation for two weeks in 2003 Nov/Dec. The data were analyzed with OSA 7.0 and FTOOLS 6.2. We derive the pulse period, light curves, spectra, hardness ratios, and hardness intensity diagrams, and study the eclipse. In addition to an already high activity level, Vela X-1 exhibited several intense flares, the brightest ones reaching a maximum intensity of more than 5 Crab in the 20-40 keV band and several off states where the source was no longer detected by INTEGRAL. We determine the pulse period to be 283.5320+/-0.0002 s, which is stable throughout the entire observation. Analyzing the eclipses provided an improvement in the ephemeris. Spectral analysis of the flares indicates that there appear to be two types of flares: ...
2008-01-01
Hard X-ray identification of Eta Carinae and steadiness close to periastron
Context: The colliding-wind binary Eta Car exhibits soft X-ray thermal emission that varies strongly around periastron, and non-thermal emission seen in hard X-rays and gamma-rays. Aims: To definitively identify Eta Car as the source of the hard X-ray emission, to examine how changes in the 2-10 keV band influence changes in the hard X-ray band, and to understand more clearly the mechanisms producing the non-thermal emission using new INTEGRAL observations obtained close to periastron. Methods: A Chandra observation encompassing the ISGRI error circle was analysed, and all other soft X-ray sources (including the outer shell of Eta Car itself) were discarded as likely counter-parts. New hard X-ray images of Eta Car were studied close to periastron, and compared to previous observations far from periastron. Results: The INTEGRAL component, when represented by a power law (with a photon index of 1.8), would produce more emission in the Chandra band than observed from ...
2010-01-01
Grain boundary transport in x-ray irradiated polycrystalline diamond
International Nuclear Information System (INIS)
The transport properties of a 'thin' polycrystalline diamond film are analyzed after the sample exposure to 8.06-keV x-ray radiation. Structure and morphology of the as-grown film have been evaluated by Raman, x-ray diffraction, and scanning electron microscopy techniques. The transport properties have been investigated by measuring dark current-voltage characteristics in the temperature range of 60 to 360 K. Ohmic transport has been evidenced on the as-grown film up to 1.16x10"5 V/cm. After irradiation, nonlinear contributions to the dark current have been evidenced and related to field-assisted thermal ionization of traps. Below 200 K, hopping mechanisms have been observed. Correlations have been found among x-ray irradiation, density of traps involved in the transport processes, and the nonhomogeneous nature of the sample. A simple model of the grain boundary structure is proposed to explain the observations.
2003-05-15
Free electron laser facilities employing a 150-MeV linac injector for Saga synchrotron light source
International Nuclear Information System (INIS)
Free electron laser (FEL) facilities as the FELI FEL Facility are proposed, for which a 150-MeV linac type injector for a Saga synchrotron light source (SLS) is employed in FEL mode. The linac has two operating modes; short macropulse mode a 1 #mu#s at 150 MeV for injection to a 1 - 1.3-GeV third generation type storage ring and long macropulse mode of 12 #mu#s at 100 MeV for four FEL Facilities. The macropulse beam consists of a train of several ps, 0.6 nC microbunches (peak current 100 A) repeating at 89.25 MHz. We are aiming to supply high power level photon beams covering an attractive wavelength range from 0.05 nm (25 keV) to 200 #mu#m (0.006 eV) for scientific researches, bio-medical and industrial applications, using the Saga third generation type SLS with a superconducting wiggler and the proposed four FEL Facilities. (author)
1999-12-01
Evidence of polarisation in the prompt gamma-ray emission from GRB 930131 and GRB 960924
The true nature of the progenitor to GRBs remains elusive; one characteristic that would constrain our understanding of the GRB mechanism considerably is gamma-ray polarimetry measurements of the initial burst flux. We present a method that interprets the prompt GRB flux as it Compton scatters off the Earth's atmosphere, based on detailed modelling of both the Earth's atmosphere and the orbiting detectors. The BATSE mission aboard the \\textit{CGRO} monitored the whole sky in the 20 keV - 1 MeV energy band continuously from April 1991 until June 2000. We present the BATSE Albedo Polarimetry System (BAPS), and show that GRB 930131 and GRB 960924 provide evidence of polarisation in their prompt flux that is consistent with degrees of polarisation of $\\Pi>35$% and $\\Pi>50$% respectively. While the evidence of polarisation is strong, the method is unable to strongly constrain the degree of polarisation beyond a systematics based estimation. Hence the ...
2005-01-01
Energy Technology Data Exchange (ETDEWEB)
(001) CZ silicon wafers were implanted with arsenic (As{sup +}) at energies of 10--50 keV to doses of 2 {times} 10{sup 14} to 5 {times} 10{sup 15}/cm{sup 2}. All implants were amorphizing in nature. The samples were annealed at 700 C for 16 hrs. The resultant defect microstructures were analyzed by XTEM and PTEM and the As profiles were analyzed by SIMS. The As profiles showed significantly enhanced diffusion in all of the annealed specimens. The diffusion enhancement was both energy and dose dependent. The lowest dose implant/annealed samples did not show As clustering which translated to a lack of defects at the projected range. At higher doses, however, projected range defects were clearly observed, presumably due to interstitials generated during As clustering. The extent of enhancement in diffusion and its relation to the defect microstructure is explained by a combination of factors including surface recombination of point defects, As precipitation, As ...
1997-11-01
International Nuclear Information System (INIS)
(001) CZ silicon wafers were implanted with arsenic (As"+) at energies of 10--50 keV to doses of 2 x 10"1"4 to 5 x 10"1"5/cm"2. All implants were amorphizing in nature. The samples were annealed at 700 C for 16 hrs. The resultant defect microstructures were analyzed by XTEM and PTEM and the As profiles were analyzed by SIMS. The As profiles showed significantly enhanced diffusion in all of the annealed specimens. The diffusion enhancement was both energy and dose dependent. The lowest dose implant/annealed samples did not show As clustering which translated to a lack of defects at the projected range. At higher doses, however, projected range defects were clearly observed, presumably due to interstitials generated during As clustering. The extent of enhancement in diffusion and its relation to the defect microstructure is explained by a combination of factors including surface recombination of point defects, As precipitation, As clustering and end of range damage.
1996-12-02
Energy Technology Data Exchange (ETDEWEB)
The effect of Al and Be ions pre-implantation on microstructural change and, the formation and growth of He bubbles in SiC/SiC composite was investigated. Four kinds of ion implanted specimens were prepared with 100 appm Al, 1000 appm Al, 100 appm Be and 1000 appm Be implanted. No microstructural change was observed in the matrices and fibers of SiC/SiC composites implanted with Al or Be ions up to 1000 appm. The un-implanted and Al or Be pre-implanted SiC/SiC composites were simultaneously irradiated to 10 dpa using triple ion-beams (6.0-MeV Si{sup 2+}, 1.0-MeV He{sup +} and 340-keV H{sup +}) at 1000 deg. C. Helium bubbles were formed in every matrix and fiber irradiated by triple ion-beams. The size of He bubbles in the matrix was increased by implanting Al or Be ions and increased with increasing amount of implanted Al or Be ions. The size of He bubbles in the fiber was slightly increased by implanting Al or Be ions. These results suggest that Al or Be as ...
2007-03-15
International Nuclear Information System (INIS)
The effect of Al and Be ions pre-implantation on microstructural change and, the formation and growth of He bubbles in SiC/SiC composite was investigated. Four kinds of ion implanted specimens were prepared with 100 appm Al, 1000 appm Al, 100 appm Be and 1000 appm Be implanted. No microstructural change was observed in the matrices and fibers of SiC/SiC composites implanted with Al or Be ions up to 1000 appm. The un-implanted and Al or Be pre-implanted SiC/SiC composites were simultaneously irradiated to 10 dpa using triple ion-beams (6.0-MeV Si"2"+, 1.0-MeV He"+ and 340-keV H"+) at 1000 deg. C. Helium bubbles were formed in every matrix and fiber irradiated by triple ion-beams. The size of He bubbles in the matrix was increased by implanting Al or Be ions and increased with increasing amount of implanted Al or Be ions. The size of He bubbles in the fiber was slightly increased by implanting Al or Be ions. These results suggest that Al or Be as transmutation ...
2007-03-01
EB-curing of coatings on wood composite boards
International Nuclear Information System (INIS)
The industrial radiation processing using low energy electron beam (EB) accelerators lower than 300 keV offers high speed, safe technologies for the chemical conversion of thin layer coatings. Because of the nonselective mode of initiating chain reaction polymerization involving free radicals in synthetic coating layers and suitable substrates, the EB curing of the coatings on woods and papers has particular advantage. Hungary decided to start an up-to-date EB line to process cement-bound (CB) wood chipboards with pigmented acrylic coatings. The CB wood chipboards contain more than 60 % of portland cement and up to 40 % of wood particles. They are produced as large boads of 6 - 16 mm thickness. In their fireproof character and other aspects, they are similar to asbestos-cement boards without containing carcinagenic asbestos, and are stable against moisture and atmospheric influences. EB-cured acrylate coating improved further those properties, and makes them ...
1988-10-01
Doping of silicon carbide by ion implantation
Energy Technology Data Exchange (ETDEWEB)
A brief survey is given of some recent results on doping of 4H- and 6H-SiC by ion implantation. The doses and energies used are between 10{sup 9} and 10{sup 15} cm{sup -2} and 100 keV and 5 MeV, respectively, and B and Al ions (p-type dopants) are predominantly studied. After low dose implantation ({<=}10{sup 10} cm{sup -2}) a strong compensation is observed in n-type samples and this holds irrespective of implantation temperature up to 600 C. However, at higher doses (10{sup 14}-10{sup 15} Al/cm{sup 2}) the rate of defect recombination (annihilation) increases substantially during hot implants ({>=}200 C), and in these samples one type of structural defect dominates after post-implant annealing at 1700-2000 C. The defect is identified as a dislocation loop composed of clustered interstitial atoms inserted on the basal plane in the hexagonal crystal structure. Finally, transient enhanced diffusion (TED) of ion-implanted boron in 4H-samples is ...
2001-07-01
Energy Technology Data Exchange (ETDEWEB)
Rotationally resolved spectra of kinetic energy releases epsilon-c in predissociations of H/sub 2/, after dissociative charge exchange of H/sub 2/ /sup +/ with Cs atoms, are obtained. The experiments are performed with natural and with pure parahydrogen. The predissociations with epsilon-c<1.9 eV constitute less than 5% of the total amount of dissociations to HXchemically bondH at a beam energy of 5 keV. All strong rotational peaks observed could be attributed to n = 3 Rydberg states which predissociate to H(1s)+H(2l). Vibrational-rotational series are observed of the d /sup 3/Pi/sub u//sup +/, D /sup 1/Pi/sub u//sup +/, and J /sup 1/..delta../sub g//sup +/ states. Predissociation by barrier tunneling is reported of v = 4 levels of the h /sup 3/..sigma../sub g//sup +/ state and of v = 4 and 5 levels of the i /sup 3/Pi/sub g/ state. Selectivity of the charge-exchange process for different n = 3 states, or even for different parity states, is concluded.
1986-11-01
Direct patterning of gold oxide thin films by focused ion-beam irradiation
International Nuclear Information System (INIS)
For direct writing of electrically conducting connections and areas into insulating gold oxide thin films a scanning Ar"+ laser beam and a 30 keV Ga"+ focused ion beam (FIB) have been used. The gold oxide films are prepared by magnetron sputtering under argon/oxygen plasma. The patterning of larger areas (dimension 10-100 #mu#m) has been carried out with the laser beam by local heating of the selected area above the decomposition temperature of AuO_x(130-150 C). For smaller dimensions (100 nm to 10 #mu#m) the FIB irradiation could be used. With both complementary methods a reduction of the sheet resistance by 6-7 orders of magnitude has been achieved in the irradiated regions (e.g. with FIB irradiation from 1.5 x 10"7#OMEGA#/#square# to approximately 6 #OMEGA#/#square#). The energy-dispersive X-ray analysis (EDX) show a considerably reduced oxygen content in the irradiated areas, and scanning electron microscopy (SEM), as well as atomic force microscopy (AFM) ...
2000-09-01
Direct evidence of the recombination of silicon interstitial atoms at the silicon surface
Energy Technology Data Exchange (ETDEWEB)
In this experiment, a Si wafer containing four lightly doped B marker layers epitaxially grown by CVD has been implanted with 100 keV Si{sup +} ions to a dose of 2 x 10{sup 14} ions/cm{sup 2} and annealed at 850 deg. C for several times in an RTA system in flowing N{sub 2}. TEM and SIMS analysis, in conjunction with a transient enhanced diffusion (TED) evaluation method based on the kick-out diffusion mechanism, have allowed us to accurately study the boron TED evolution in presence of extended defects. We show that the silicon surface plays a key role in the recombination of Si interstitial atoms by providing the first experimental evidence of the resulting Si{sub int}s supersaturation gradient between the defect region and the surface. Our results indicate an upper limit of about 200 nm for the surface recombination length of Si interstitials at 850 deg. C in a N{sub 2} ambient.
2004-02-01
Direct evidence of the recombination of silicon interstitial atoms at the silicon surface
International Nuclear Information System (INIS)
In this experiment, a Si wafer containing four lightly doped B marker layers epitaxially grown by CVD has been implanted with 100 keV Si"+ ions to a dose of 2 x 10"1"4 ions/cm"2 and annealed at 850 deg. C for several times in an RTA system in flowing N_2. TEM and SIMS analysis, in conjunction with a transient enhanced diffusion (TED) evaluation method based on the kick-out diffusion mechanism, have allowed us to accurately study the boron TED evolution in presence of extended defects. We show that the silicon surface plays a key role in the recombination of Si interstitial atoms by providing the first experimental evidence of the resulting Si_i_n_ts supersaturation gradient between the defect region and the surface. Our results indicate an upper limit of about 200 nm for the surface recombination length of Si interstitials at 850 deg. C in a N_2 ambient.
2004-02-01
Development of real time personal neutron dosimeter with two silicon detectors
Energy Technology Data Exchange (ETDEWEB)
The personal neutron dosimetry becomes more important with the increasing use of nuclear and accelerator facilities. The solid state track detector, film badge and thermo-luminescent dosimeter have widely been used as passive-type personal neutron dosimeters, but the real-time neutron dosimeter is strongly needed. A real time personal dosimeter which could give neutron dose equivalent over wide energy range from thermal to 10 odd MeV by using two neutron sensors has been developed by our group. For practical commercial product, some changes from these prototype sensors have recently been done by Fuji Electric Co. Ltd. The purpose of this work is the final performance test of the dosimeter just before sale. We checked again about the sensitivity in the monoenergetic neutron field from 8 keV to 15 MeV and in the neutron fields around a few accelerator facilities. (author)
1997-07-01
The authors develop a procedure for the determination of the Al, Ti, V, Cu, Mn, Mo, and W content of nickel-base alloys by neutron activation analysis. An M-10 microtron with a beryllium target in a paraffin microtron (with a beryllium target) in a paraffin moderator served as the neutron source. In order to evaluate the procedure for quantitative analysis, the authors determined the contents of the above elements in five reference standards, the bulk density of which was 2.94-4.17 g/cm/sup 3/. The difference in the self-absorption of the gammaquanta was assessed by determining the number of gamma-quanta with energies in the range 60-1332 keV that had passed through the RS N4 and N8 which showed the greatest difference in their composition. The results of the determination are presented. The proposed procedure is simple and rapid and can be used to determine the alloying components of nickel-based alloys with satisfactory precision.
1986-04-01
International Nuclear Information System (INIS)
The authors develop a procedure for the determination of the Al, Ti, V, Cu, Mn, Mo, and W content of nickel-base alloys by neutron activation analysis. An M-10 microtron with a beryllium target in a paraffin microtron (with a beryllium target) in a paraffin moderator served as the neutron source. In order to evaluate the procedure for quantitative analysis, the authors determined the contents of the above elements in five reference standards, the bulk density of which was 2.94-4.17 g/cm"3. The difference in the self-absorption of the gammaquanta was assessed by determining the number of gamma-quanta with energies in the range 60-1332 keV that had passed through the RS N4 and N8 which showed the greatest difference in their composition. The results of the determination are presented. The proposed procedure is simple and rapid and can be used to determine the alloying components of nickel-based alloys with satisfactory precision.
Design of a GaAs X-ray imaging sensor with integrated HEMT readout circuitry
A new monolithic semi-insulating (SI) GaAs sensor design for X-ray imaging applications between 10-100keV has been proposed. Monolithic pixel detectors offer a number of advantages over hybrid bump-bonded detectors, such as high device yield, low costs and are easier to produce large scale arrays. In this thesis, an investigation is made of the use of a SI GaAs wafer as both a detector element and substrate for the epitaxially grown High Electron Mobility Transistors (HEMTs). The design of the HEMT transistors, optimised for this application, were produced with the aid of the Silvaco 'Virtual Wafer Fab' simulation package. It was determined that the device characteristics would consist of a small positive threshold voltage, a low off-state drain current and high transconductance. The final HEMT transistor design, that would be integrated to a pixel detector, had a threshold voltage of 0.17V, an off-state leakage current of approx 1nA and a transconductance of ...
2002-01-01
Energy Technology Data Exchange (ETDEWEB)
We report on the elimination of defect formation which is associated with high dose indium implantations under solid phase epitaxial regrowth (SPER) annealing conditions of 650-800 deg. C. This is achieved by incorporating a layer of epitaxially grown Si{sub 1-y}C {sub y} layer, strategically located at the end-of-range (EOR) of the implant profile. An indium implant of 115 keV at 1 x 10{sup 14} cm{sup -2} was performed followed by annealing at temperature ranges of 650-800 deg. C. Samples with the Si{sub 1-y}C {sub y} layer revealed the elimination of secondary EOR defects with effectively suppressed indium transient enhanced diffusion (TED), indicating the function of carbon as an efficient sink for silicon interstitials at reduced annealing temperatures, in the SPER dopant activation regime.
2006-05-10
International Nuclear Information System (INIS)
We report a study of the physical characteristics of the pillars of C, Pt and W grown by 10-30 keV Ga focused ion beam (FIB) as a function of Ga ion flux, and present a quantitative analysis of the elements using energy-dispersive analysis of X-rays (EDAX). All the FIB grown pillars exhibit a rough morphology with whisker like protrusions on the cylindrical surface and broadening of the base as compared to the nominal size. For a constant fluence, the height of the pillar initially increases and then reduces after going through a maximum as a function of ion flux in all the cases. The compositional analysis shows good metallic quality for Pt structures but reveals significant contamination of Ga in C and Ga and C in W structures at higher ion fluxes. Explanation to all these observations has been sought in the light of secondary ion and electron effects and the different processes involved which lead to the FIB induced deposition.
2008-04-01
CoSi_2 nanostructures by writing FIB ion beam synthesis
International Nuclear Information System (INIS)
A mass separated focused ion beam (FIB) is a very useful tool to fabricate nanostructures by writing implantation within an ion beam synthesis process. In these investigations the IMSA-OrsayPhysics FIB, equipped with a Co_3_6Nd_6_4 alloy liquid metal ion source, was applied. Si(100) and (111) wafers were implanted with 60 keV Co"+"+ ions in the dose range of 2 . 10"1"6 to 2 . 10"1"7 cm"-"2. Implantation parameters were investigated, like pixel dwell time, relaxation time (time between two cycles), dose rate as well as the pixel overlapping factor. The subsequent annealing was done in a two step process, namely 600 deg. C for 60 min and 1000 deg. C for 30 min in a N_2 ambient. The results obtained by SEM investigations in terms of continuous nanowire structures following the direction and interrupted CoSi_2 pattern in the direction show a clear dependence on the time scale as well as the scanning mode of the irradiation. Structure sizes as small as 10 nm are ...
2006-07-01
Chandra Observations of Nuclear X-ray Emission from a Sample of Radio Sources
We present the X-ray properties of a sample of 17 radio sources observed with the Chandra X-ray Observatory as part of a project aimed at studying the X-ray emission from their radio jets. In this paper, we concentrate on the X-ray properties of the unresolved cores. The sample includes 16 quasars (11 core-dominated and 5 lobe-dominated) in the redshift range z=0.30--1.96, and one low-power radio-galaxy at z=0.064. No diffuse X-ray emission is present around the cores of the quasars, except for the nearby low-power galaxy that has diffuse emission on a scale and with a luminosity consistent with other FRIs. No high-amplitude, short-term variability is detected within the relatively short Chandra exposures. However, 1510-089 shows low-amplitude flux changes with a timescale of $\\sim$25 minutes. The X-ray spectra of the quasar cores are generally well described by a single power law model with Galactic absorption. However, in six quasars we find soft X-ray excess emission below 1.6 ...
2003-01-01
Boron-enhanced diffusion of boron from ultralow-energy ion implantation
Energy Technology Data Exchange (ETDEWEB)
We have investigated the diffusion enhancement mechanism of boron-enhanced diffusion (BED), wherein boron diffusivity is enhanced four to five times over the equilibrium diffusivity at 1050&hthinsp;{degree}C in the proximity of a silicon layer containing a high boron concentration. It is demonstrated that BED is driven by excess interstitials injected from the high boron concentration layer during annealing. For evaporated layers, BED is observed above a threshold boron concentration between 1{percent} and 10{percent}, though it appears to be closer to 1{percent} for B-implanted layers. For sub-keV B implants above the threshold, BED dominates over the contribution from transient-enhanced diffusion to junction depth. For 0.5 keV B, this threshold implantation dose lies between 3{times}10{sup 14} and 1{times}10{sup 15} cm{sup {minus}2}. It is proposed that the excess interstitials responsible for BED are produced during the formation of a silicon boride phase in ...
1999-04-01
Boron-enhanced diffusion of boron from ultralow-energy ion implantation
International Nuclear Information System (INIS)
We have investigated the diffusion enhancement mechanism of boron-enhanced diffusion (BED), wherein boron diffusivity is enhanced four to five times over the equilibrium diffusivity at 1050 ampersand hthinsp;degree C in the proximity of a silicon layer containing a high boron concentration. It is demonstrated that BED is driven by excess interstitials injected from the high boron concentration layer during annealing. For evaporated layers, BED is observed above a threshold boron concentration between 1% and 10%, though it appears to be closer to 1% for B-implanted layers. For sub-keV B implants above the threshold, BED dominates over the contribution from transient-enhanced diffusion to junction depth. For 0.5 keV B, this threshold implantation dose lies between 3x10"1"4 and 1x10"1"5 cm"-"2. It is proposed that the excess interstitials responsible for BED are produced during the formation of a silicon boride phase in the high B concentration layers. copyright 1999 ...
1999-04-01
Boron transient enhanced diffusion in heavily phosphorus doped silicon
Energy Technology Data Exchange (ETDEWEB)
A study has been made of B transient enhanced diffusion (TED) in heavily P-doped Si using secondary ion mass spectroscopy (SIMS) and positron annihilation spectroscopy (PAS). The P-doped silicon was implanted with boron ions of 40 keV energy to a dose of 3 {times} 10{sup 14} cm{sup {minus}2}, and then annealed at temperatures ranging from 700--1,000 C in a N{sub 2} ambient for varying durations. As P doping concentration increased from 3 {times} 10{sup 19} to 1 {times} 10{sup 20} cm{sup {minus}3}, boron diffusivity and the immobile boron fraction decreased. The experimental results are inconsistent with the predictions of the Fermi-level model and suggest that the clustering between B atoms and Si interstitials should be invoked in order to explain the immobile portion of the B peak during TED.
1997-11-01
International Nuclear Information System (INIS)
The neutron capture cross sections of the stable molybdenum isotopes have been measured with high energy resolution (#DELTA#E/E < approximately 0.2%), between 3 and 90 keV neutron energy, at the 40 m station of ORELA. Average resonance parameters are extracted for s- and p-wave resonances. The s-wave neutron strength function is close to 0.5x10"-"4 for all isotopes, but the p-wave strength function exhibits a well defined peak near A approximately 95. Both s- and p-wave radiative widths decrease markedly as further neutrons are added to the closed shell. The p-wave radiative widths are generally greater than the s-wave widths showing the presence of non-statistical #gamma#-decay mechanisms. Valence neutron theory fails to explain the magnitude of the p- to s-wave radiative width disparity and doorway state processes are invoked. In particular, the data for "9"8Mo appear to violate the usual valence theory, since the correlations between radiative and neutron ...
Energy Technology Data Exchange (ETDEWEB)
A new atomistic approach to Si device process simulation is presented. It is based on a Monte Carlo diffusion code coupled to a binary collision program. Besides diffusion, the simulation includes recombination of vacancies and interstitials, clustering and re-emission from the clusters, and trapping of interstitials. We discuss the simulation of a typical room-temperature implant at 40 keV, 5{times}10{sup 13} cm{sup {minus}2} Si into (001)Si, followed by a high temperature (815{degree}C) anneal. The damage evolves into an excess of interstitials in the form of extended defects and with a total number close to the implanted dose. This result explains the success of the {open_quote}{open_quote}+1{close_quote}{close_quote} model, used to simulate transient diffusion of dopants after ion implantation. It is also in agreement with recent transmission electron microscopy observations of the number of interstitials stored in (311) defects. {copyright} {ital 1996 American ...
1996-01-01
International Nuclear Information System (INIS)
A new atomistic approach to Si device process simulation is presented. It is based on a Monte Carlo diffusion code coupled to a binary collision program. Besides diffusion, the simulation includes recombination of vacancies and interstitials, clustering and re-emission from the clusters, and trapping of interstitials. We discuss the simulation of a typical room-temperature implant at 40 keV, 5x10"1"3 cm"-"2 Si into (001)Si, followed by a high temperature (815 degree C) anneal. The damage evolves into an excess of interstitials in the form of extended defects and with a total number close to the implanted dose. This result explains the success of the open-quote open-quote+1 close-quote close-quote model, used to simulate transient diffusion of dopants after ion implantation. It is also in agreement with recent transmission electron microscopy observations of the number of interstitials stored in (311) defects. copyright 1996 American Institute of Physics.
Atomic masses of "6Li,"2"3Na,"3"9","4"1K,"8"5","8"7Rb, and "1"3"3Cs
International Nuclear Information System (INIS)
The atomic masses of the alkali-metal isotopes "6Li,"2"3Na,"3"9","4"1K,"8"5","8"7Rb, and "1"3"3Cs have been obtained from measurements of cyclotron frequency ratios of pairs of ions simultaneously trapped in a Penning trap. The results, with one standard deviation uncertainty, are: M("6Li)=6.015 122 887 4(16)u,M("2"3Na)=22.989769 282 8(26)u,M("3"9K)=38.963 706 485 6(52)u,M("4"1K)=40.961 825 257 4(48)u,M("8"5Rb)=84.911 789739(9)u,M("8"7Rb)=86.909 180 535(10)u, and M("1"3"3Cs)=132.905 451 963(13)u. Our mass of "6Li yields an improved neutron separation energy for "7Li of 7251.1014(45) keV.
2010-10-01
Alloying effect on K to L shell vacancy transfer probabilities in 3d transition metals
British Library Electronic Table of Contents (United Kingdom)
The alloying effects on K to L shell vacancy transfer probabilities (?KL) in 3d transition metals have been carried out by X-ray fluorescence studies of various alloy compositions. K X-ray intensity ratios of Ti, Cr, Fe, Co, Ni, and Cu elements in the FexNi1?x, FexCr1?x, NixCr1?x, FexCryNi1?(x+y), TixNi1?x, TixCo1?x, and CoxCu1?x alloys have been measured following excitation by 22.69keV X-rays from a 10 mCi 109Cd radioactive point source and ?KL values for alloying elements have been determined from these ratios. The spectrum of characteristic K-X-ray photons from samples were detected with a high resolution Si(Li) detector coupled to a 4 K multichannel analyzer. The present investigation makes it possible to ...
2010-01-01
A Distinctive Disk-Jet Coupling in the Seyfert-1 AGN NGC 4051
We report on the results of a simultaneous monitoring campaign employing eight Chandra X-ray (0.5-10 keV) and six VLA/EVLA (8.4 GHz) radio observations of NGC 4051 over seven months. Evidence for compact jets is observed in the 8.4 GHz radio band; This builds on mounting evidence that jet production may be prevalent even in radio-quiet Seyferts. Assuming comparatively negligible local diffuse emission in the nucleus, the results also demonstrate an inverse correlation of L_radio proportional to L_X-ray ^(-0.72+/-0.04) . Current research linking the mass of supermassive black holes and stellar-mass black holes in the "low/hard" state to X-ray luminosities and radio luminosities suggest a "fundamental plane of accretion onto black holes" that has a positive correlation of L_radio proportional to L_X-ray^(0.67+/-0.12) . Our simultaneous results differ from this relation by more than 11 sigma, indicating that a separate mode of accretion and ejection may operate in ...
2010-01-01
In vivo and in vitro evaluation of dota-lanreotide radiolabelled with gallium-67
International Nuclear Information System (INIS)
One of the refinements of modern Nuclear Medicine is the capacity of providing dynamic and kinetics images of the administered radiopharmaceutical, reproducing its transport mechanism, action sites, receptor binding and excretion route. With the continues technological advances new radiopharmaceuticals have been developed in order to express higher specificity and with higher characters of affinity between receptor/complex. One radiopharmaceutical is formed by a reagent or bio molecule that has in its structure a radioisotope, that has the objectives of carrying it to the organs of affinity or to benign or malign tumoral process. Somatostatin inhibits the growing and proliferation of several tumoral cells. Somatostatin analogs bind to somatostatic receptors that are expressed in different kind of neoplasia DOTA-LANREOTIDE (DOTALAN) is an octapeptide analog to somatostatin. The interest of labeling the bio conjugate with gallium-67 in Nuclear Medicine comes from its physical, chemical ...
X-ray dosimetry of TlGaSe_2 single crystals
International Nuclear Information System (INIS)
TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. X-ray conductivity coefficients K_#sigma# characterising X-ray sensitivity of investigated crystals are determined as the relative change of conductivity ...
Radioactive targets for neutron-induced cross section measurements
Measurements using radioactive targets are important for the determination of key reaction path ways associated with the synthesis of the elements in nuclear astrophysics (sprocess), advanced fuel cycle initiative (transmutation of radioactive waste), and stockpile stewardship. High precision capture cross-section measurements are needed to interpret observations, predict elemental or isotopical ratios, and unobserved abundances. There are two new detector systems that are presently being commissioned at Los Alamos National Laboratory for very precise measurements of (n,{gamma}) and (n,f) cross-sections using small quantities of radioactive samples. DANCE (Detector for Advanced Neutron-Capture Experiments), a 4 {pi} gamma array made up of 160 BaF{sub 2} detectors, is designed to measure neutron capture cross-sections of unstable nuclei in the low-energy range (thermal to {approx}500 keV). The high granularity and high detection efficiency of DANCE, combined with ...
2004-01-01
Energy Technology Data Exchange (ETDEWEB)
A new generation of quasimonochromatic high-flux X-ray sources, based on the X-ray radiation produced through Compton scattering between an electron beam and a laser beam, is under development. One of the possible applications of this source is inline phase contrast mammography, based on the observation of the edge-enhancement effect that can be observed at the border of structures inside the breast in images produced using a partially or totally coherent X-ray beam. In this work we present the results of a set of simulations of inline phase contrast mammography using typical inverse Compton scattering sources parameters. The simulated sample was a tumour-like mass having spherical shape, diameter between 200 {mu}m and 5 mm, placed inside a breast-like matrix, 4 cm thick, and a standard composition of 50% glandular tissue and 50% adipose tissue. We discuss the minimum requirements for mammography using inverse Compton scattering sources and we discuss how the working parameters of the ...
2009-09-01
Transient enhanced diffusion from decaborane molecular ion implantation
Energy Technology Data Exchange (ETDEWEB)
Transient enhanced diffusion (TED) from implantation of 5thinspkeVthinspB{sub 10}H{sub 14} and 0.5 keV B ions has been quantified and compared for nominal boron doses of 10{sup 14} and 10{sup 15}thinspcm{sup {minus}2}. Boron diffusivity during annealing was extracted from secondary ion mass spectroscopy depth profiles of diffused marker layers in boron doping-superlattices and the actual implanted B dose was independently measured by nuclear reaction analysis. Comparable enhancements were observed from both ions. Transmission electron microscopy analysis revealed that both boron- and decaborane-implanted samples were amorphized at a nominal 10{sup 15}thinspcm{sup {minus}2}thinspB dose. A comparison with data from low energy Si implants revealed a similar dependence of diffusivity enhancement on implant dose. These findings are consistent with the understanding that TED is caused by the interstitial supersaturation resulting from a number of excess interstitials ...
1998-10-01
Transient enhanced diffusion from decaborane molecular ion implantation
International Nuclear Information System (INIS)
Transient enhanced diffusion (TED) from implantation of 5keVB_1_0H_1_4 and 0.5 keV B ions has been quantified and compared for nominal boron doses of 10"1"4 and 10"1"5cm"-"2. Boron diffusivity during annealing was extracted from secondary ion mass spectroscopy depth profiles of diffused marker layers in boron doping-superlattices and the actual implanted B dose was independently measured by nuclear reaction analysis. Comparable enhancements were observed from both ions. Transmission electron microscopy analysis revealed that both boron- and decaborane-implanted samples were amorphized at a nominal 10"1"5cm"-"2B dose. A comparison with data from low energy Si implants revealed a similar dependence of diffusivity enhancement on implant dose. These findings are consistent with the understanding that TED is caused by the interstitial supersaturation resulting from a number of excess interstitials approximately equal to the number of implanted atoms which can become ...
1998-10-01
The JT-60U 2.45 MeV neutron time-of-flight spectrometer
Energy Technology Data Exchange (ETDEWEB)
A 2.45 MeV neutron time-of-flight spectrometer was designed and built for measurements of neutron energy spectra from the JT-60U Tokamak. The spectrometer consists of two fast plastic scintillators (50 cm{sup 2} and 1800 cm{sup 2}, thickness: 2 cm) where each detector is located on two constant time-of-flight spheres. The time-of-flight spheres have radius of 1 m which gives a neutron flight length of {approx}164 cm and a time-of-flight of {approx}92 ns for 2.45 MeV source neutrons. The calculated spectrometer efficiency and resolution are 2.8 x 10{sup -2} cm{sup 2} and 105 keV (4.3%), respectively. The energy resolution corresponds to a time resolution of 2.0 ns. The spectrometer will measure neutrons in a vertical line-of-sight, {approx}9 m from the plasma center. For a total neutron emission of 10{sup 16} n/s, the countrate in the first scattering detector, located in the neutron beam, is estimated to {approx}2.5 MHz. The useful countrate for this case is ...
1999-11-01
Status of the WAND (Waste Assay for Nonradioactive Disposal) project as of July 1997
Energy Technology Data Exchange (ETDEWEB)
The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole system and to perform the data analysis. WAND system minimum detectable activities (MDAs) for point sources range from ...
1998-03-01
Status of lead and bismuth for radioimmunoimaging and radioimmunotherapy
International Nuclear Information System (INIS)
Tumor-targeted monoclonal antibodies (mAb) might be useful as diagnostic or therapeutic agents when linked to cytotoxic or imaging reagents. Our group is working to test this hypothesis by linking cytocidal and image-producing isotopes to mAb and testing the utility of the radioimmunoconjugates formed in animal model systems. Radioiodines were first employed for these purposes,but unfavorable nuclear properties (half-lives, #gamma#-ray and #beta#-particle energies) and chemical reactivity (deiodination in vivo) limit their utility. Labeling immunoproteins with metallic radionuclides offers more versatility in that the selection of potentially useful radiometals spans the periodic table.Of the metallic radionuclides with physical properties most suited for use with mAb in nuclear medicine, few are more available or desirable than those of bismuth ("2"1"2Bi) and lead ("2"0"3Pb, "2"1"2Pb), as listed in Table 1. "2"1"2Bi or "2"1"2Pb could serve as sources for highly cytocidal ...
1990-08-26
Reevaluation of 58Ni and 60Ni Resonance Parameters in the Energy Range Thermal to 800 keV
Energy Technology Data Exchange (ETDEWEB)
The previous 58Ni and 60Ni set of resonance parameters (ENDF/B-VII-0, JEFF-3, etc.) was based on the SAMMY analysis of Oak Ridge National Laboratory neutron transmission, scattering cross section and capture cross section measurements by C. M. Perey et al. The present results were obtained by adding to the SAMMY experimental data base the capture cross sections measured recently at the Oak Ridge Linear Electron Accelerator by Guber et al. and the Geel Electron Linear Accelerator very high-resolution neutron transmission measurements performed by Brusegan et al. A complete resonance parameter covariance matrix (RPCM) was obtained from the SAMMY analysis of the experimental database. The data sets were made consistent, when needed, by adjusting the neutron energy scales, the normalization coefficients, and the background corrections. The RPCM allows the calculation of the cross section uncertainties due mainly to statistical errors in the experimental data. The systematic uncertainties ...
2009-09-01
Energy Technology Data Exchange (ETDEWEB)
The previous {sup 58}Ni and {sup 60}Ni set of resonance parameters (Endf/B7.O, Jeff-3, etc.) was based on the SAMMY analysis of Oak Ridge National Laboratory neutron transmission, scattering cross section and capture cross section measurements by C.M. Perey et al. The present results were obtained by adding to the SAMMY experimental database the capture cross sections measured recently at the Oak Ridge Linear Electron Accelerator by Guber et al. and the Geel Electron Linear Accelerator and very high-resolution neutron transmission measurements performed by Brusegan et al. A complete resonance parameter covariance matrix (RPCM) was obtained from the SAMMY analysis of the experimental database. The data sets were made consistent, when needed, by adjusting the neutron energy scales, the normalization coefficients, and the background corrections. The RPCM allows the calculation of the cross section uncertainties due mainly to statistical errors in the experimental data. The systematic ...
2009-07-01
Optical image storage in ion implanted PLZT ceramics
International Nuclear Information System (INIS)
We have demonstrated that optical images can be stored in transparent lead-lanthanum-zirconate-titanate (PLZT) ceramics by exposure to near-UV light with photon energies greater than the band gap energy of approx. equal to 3.35 eV. The image storage process relies on optically induced changes in the switching properties of ferroelectric domains (photoferroelectric effect). Stored images are nonvolatile but can be erased by uniform UV illumination and simultaneous application of an electric field. Although high quality images, with contrast variations of >= 100:1 and spatial resolution of approx. equal to 10 #mu#m, can be stored using the photoferroelectric effect, relatively high exposure energies (approx. equal to 100 mJ/cm"2) are required to store these images. This large exposure energy severely limits the range of possible applications of nonvolatile image storage in PLZT ceramics. We have recently found from studies of H, He and Ar implanted PLZT that the photosensitivity can ...
International Nuclear Information System (INIS)
The authors report on observations of plasma wave turbulence generated during electron beam injections, spacecraft potential variations, and neutral gas emissions of the CHARGE 2 sounding rocket experiment. The payload was flown in a mother/daughter configuration, with the two sub-payloads electrically connected by an insulated, conducting tether. While tethered, the two platforms were separated, drifting apart in a direction perpendicular to both the magnetic field and to the spacecraft velocity, reaching a maximum distance of 426 m at the end of the flight. The mother carried a high-voltage (HV) system (0-460 V), biasing the mother negative relative to the daughter. The operation of the HV bias system simulated the motional emf induced in larger orbiting space structures like the Tethered Satellite System 1 (TSS 1) space shuttle mission scheduled for the spring of 1992. In addition, the mother carried an electron beam accelerator (1 keV, 0-46 mA). The daughter ...
Nuclear radiation detectors on II-VI compounds
International Nuclear Information System (INIS)
Nuclear radiation detectors in integral execution were produced by successive epitaxial growth from vapor phase of Zn Te and Cd Se thin layers onto scintillating Zn Se (Te) crystals. The irradiation of combined Zn Se (Te) - Zn Te - Cd Se detectors by Cu_K_a X-rays leads to the appearance of photoreceiver e.m.f., which tends to saturation with the increase of X-ray radiation dose reaching the value of 0.34-0.40 V at 200 R/min. The short circuit current dependence of irradiation dose power is linear. The matching factor for detectors with Zn Te-Cd Se photoreceivers with different doping levels is 0.68-0.92. The absolute monochromatic sensitivity is 0.32-0.35 m A/m W at a quantum efficiency 0.58-0.61 and a time constant 2 x 10"-"4 s. The calculated dose sensitivity for Zn Se(Te)-Zn Te-Cd Se combined detectors at the irradiation with X-rays having effective energy 8.86 keV gives the value 3.9 x 10"-"7 A/cm"2 (R/min); the experimental value of dose sensitivity reaches ...
1993-10-13
Initiation of ecton processes by interaction of a plasma with a microprotrusion on a metal surface
International Nuclear Information System (INIS)
Evolution of rapid (?10 ns) Ohmic overheating of a microprotrusion on a surface in contact with a plasma by emission current is studied taking into account the energy carried by plasma ions and electrons, as well as Ohmic heating, emissive source of energy release (Nottingham effect), and heat removal due to heat conduction. Plasma parameters were considered in the range of n = 1014-1020 cm-3 and Te = 0.1 eV-10 keV. The threshold value of energy transferred to the surface from the plasma is found to be 200 MW/cm2; above this value, heating becomes explosive (namely, an increase in the temperature growth rate (?2T/?t2 > 0) and in passing current (?J/?t > 0) is observed in the final stage at T ? 104 K and j ? 108 A/cm2). In spite of the fact that Ohmic heating does not play any significant role for plasmas with a density lower than 10 18 cm-3 because the current is limited by the space charge of electrons, rapid overheating of top of microprotrusion is observed ...
2008-12-01
Impurity and clustering effects on defect evolution in ion-implanted Si
Energy Technology Data Exchange (ETDEWEB)
A detailed investigation of the damage formation and evolution in ion-implanted crystalline Si is presented. Deep-level transient spectroscopy has been used to monitor room temperature migration of point defect complexes and evolution from simple point-like defect complexes to defect clusters and even extended defects. Si samples were implanted with Si or He ions with energies of 145 keV-3MeV, to fluences in the range 5x10[sup 8]-5x10[sup 13]cm[sup -2]. The effects of thermal annealing, in the range 100-680 C and 10 min-15h, were also explored. A systematic comparison of defect complexes formation and evolution in ion-implanted or electron-irradiated Si samples with a different impurity content were used to assess the role of impurities (C and O), extra implanted ion and defect clustering on the nature and thermal stability of residual damage. In particular, an interstitial excess directly resulting from the extra implanted ion is shown to dominate the residual ...
1998-10-01
Extension of improved particle and energy confinement regime in the core of LHD plasma
International Nuclear Information System (INIS)
Recent two major topics of Large Helical Device (LHD) towards fusion relevant conditions, high-density operation and high-ion-temperature operation, are reported. Super dense core plasma was obtained by the combination of repetitive hydrogen ice pellet injection and high power neutral beam injection (NBI) heating. A very peaked density profile with the highest central density of 1.1x1021 m-3 was produced showing that the particle transport was suppressed very well in the plasma core. The spatial density varies as the position of magnetic axis (Rax), and the steepest profile is obtained at Rax=3.95 m. The highest central ion temperature of 5.6 keV was obtained in hydrogen plasma at electron density of 1.6 x 1019 m-3 by NBI, where a peaked ion-temperature profile with internal ion energy transport barrier was observed. The profile of electron temperature did not change much and was broad even when the ion temperature had a peaked profile. The central ion temperature ...
2009-06-01
Effect of nitrogen segregation on TED and loss of phosphorus in CZ-Si
International Nuclear Information System (INIS)
Transient enhanced diffusion (TED) and dose loss (pile-up) are investigated for phosphorus-implanted samples covered with both oxide and nitride films. P ions were implanted into p-type (1 0 0) CZ-Si (dose 5x10"1"3 cm"-"3, 100 keV) through a chemical vapor deposition (CVD) Si_3N_4 film. For a half of samples, Si_3N_4 was etched off and SiO_2 films were grown by CVD. Both samples were annealed for 20-360 min at 700 deg. C. Diffusivity of P and the dose loss were estimated based on the secondary-ion mass spectrometry (SIMS) P profiles. Both Si/Si_3N_4 and Si/SiO_2 interfaces were investigated with transmission electron microscopy (TEM) and electron energy-loss spectroscopy (EELS). There is no significant difference in P diffusivity between the SiO_2 and Si_3N_4 films for the present annealing condition of 700 deg. C for 20-360 min. Regarding dose loss, a distinct different behavior was observed. In case of the SiO_2 cover film, amount of dose decreases with the ...
2002-01-01
International Nuclear Information System (INIS)
Effects of helium and hydrogen production on irradiation hardening of martensitic steel F82H (Fe-8Cr-2W-0.2V-0.04Ta-0.1C) were examined by dual or triple beam experiments. The effects of tempering and cold working were also examined. The irradiations were performed at about 500degC to 50 dpa under simultaneous dual beams of 10.5 MeV Fe"3"+ and 1.05 MeV He"+ or triple beams of those and 380 keV H"+ ions. The value of appm-He/dpa for the dual ion beams was about 15, and the values of appm-He/dpa and appm-H/dpa for the triple ion beams were 15 and 15 (or 150), respectively. The hardness of the irradiated specimens measured at room temperature using a micro indentation after the irradiations. Irradiation softening and hardening was observed in F82H-std, F82H+20%CW and a non-tempered F82H steels irradiated at about 500degC to 18 and 50 dpa, respectively, by dual ion beams. The hardness of the specimens irradiated at about 500degC to 18 dpa under triple ion beams was ...
2007-06-01
International Nuclear Information System (INIS)
Effect of helium and hydrogen production on radiation-hardening of F82H irradiated by dual or triple beam condition were investigated. The specimens used were four types of ferritic martensitic steels of F82H-std (Fe-8Cr-2W-0.2V-0.04Ta-0.1C) steels tempered at 750degC for 60 minutes, 20% cold worked F82H steel, F82H tempered for 10 minutes and non-tempered F82H steels. The irradiation was performed at 450degC to 50 dpa under simultaneous dual beams of 10.5 MeV Fe"3"+ and 1.05 MeV He"+ or triple beams of those and 380 keV H"+ ions. The ratios of He (appm)/dpa and H(appm)/dpa were 15 nad 15 (or 150) for dual and triple ion beams. The hardness of the irradiated specimens measured at room temperature using a micro indentation after the irradiations. The hardness in these F82H steels irradiated at 450degC to 18 dpa under triple beam irradiation was harder than that under dual beam irradiation. Irradiation softening and hardening under dual beams was observed in F82H ...
2003-03-01
Construction, testing of the 1 MW, 130-260 GHz Fusion-FEM
Energy Technology Data Exchange (ETDEWEB)
During the previous 9 months the major part of the Fusion-FEM has been constructed. The 2 MV Insulated Core Transformer, the electron gun, the accelerator, the focusing lenses and the undulator have been tested on-site. In the present - temporary - set-up, the electron beam line consists of a 12 A, 80 keV thermionic electron gun, a 2 MeV dc accelerator, beam transport optics, the undulator and a collector. The gun is mounted in the high voltage terminal, which is now at -2 MV, and the undulator and mm-wave system am at ground potential outside the SF{sub 6}-filled pressure tank. This so-called inverse set-up allows easy access to the larger part of the beam line, the undulator and the mm-wave system, which is important in the conditioning phase. The decelerator and depressed collector am not yet installed. The design of the electron beam line has been optimised using the GPS particle-tracking code and the TOSCA code. The TOSCA code is used for accurate field ...
1995-12-31
Central engine of quasars and AGNs: a relativistic proton radiative shock
International Nuclear Information System (INIS)
Active galactic nuclei (AGNs) and quasars (QSOs) appear to emit roughly equal energy per decade from radio to gamma-ray energies (e.g. Ramaty and Ligenfelter 1982). This argues strongly for a nonthermal radiation mechanism (see Rees 1984). In addition, statistical studies have indicated that the spectra of these objects in the IR-UV and 2 to 50 keV x-ray band, can be fitted very well with power laws of specific indices. These spectral indices do not seem to depend on the luminosity or morphology of the objects (Rothschild et al. 1983; Malkan 1984), and any theory should account for them in a basic and model independent way. If shocks accelerate relativistic protons via the first-order Fermi mechanism (e.g. Axfor 1981), the radiating electrons can be produced as secondaries throughout the source by proton-proton (p-p) collisions and pion decay, thus eliminating Compton losses (Protheroe and Kazanas 1983). As shown by Kazanas (1984), if relativistic electrons are ...
1985-08-01
Energy Technology Data Exchange (ETDEWEB)
The importance of cellular dosimetry in both diagnostic and therapeutic nuclear medicine is becoming increasingly recognized. Experimental range-energy relations for electrons and alpha particles, along with derived geometric reduction factors, are used to calculate cellular absorbed fractions for these radiations. The resulting absorbed fractions are employed to calculate cellular S-values for several radionuclides. Cellular absorbed fractions for monoenergetic electron sources with energies ranging from 0.1 keV to 1 MeV, distributed uniformly in the source region, are calculated for several target {l_arrow} source combinations including cell{l_arrow}cell, cell{l_arrow}cell surface, nucleus{l_arrow}nucleus, nucleus {l_arrow}cytoplasm and nucleus {l_arrow}cell surface. Similar data are also provided for monoenergetic alpha particle sources with energies ranging from 3 to 10 MeV. S-values are also conveniently tabulated for {sup 32}P, {sup 35}S, {sup 86}Rb, {sup ...
1994-02-01
Energy Technology Data Exchange (ETDEWEB)
The influence of substrate temperature on both the implantation and post-annealing characteristics of molecular-ion-implanted 5 x 10{sup 14} cm{sup -2} 77 keV BSi in silicon was investigated in terms of boron depth profiles and damage microstructures. The substrate temperatures under investigation consisted of room temperature (RT) and liquid nitrogen temperature (LT). Post-annealing treatments were performed using rapid thermal annealing (RTA) at 1050 deg, C for 25 s. Boron depth profiles and damage microstructures in both the as-implanted and as-annealed specimens were determined using secondary ion mass spectrometry (SIMS) and transmission electron microscopy (TEM), respectively. The as-implanted results revealed that, compared to the RT specimen, the LT specimen yields a shallower boron depth profile with a reduced tail into the bulk. An amorphous layer containing a smooth amorphous-to-crystalline (a/c) interface is evident in the LT specimen while just the ...
2007-08-15
International Nuclear Information System (INIS)
This paper introduces the JNM Special Issue on the development of a first wall for the reaction chamber in a laser fusion power plant. In this approach to fusion energy a spherical target is injected into a large chamber and heated to fusion burn by an array of lasers. The target emissions are absorbed by the wall and encapsulating blanket, and the resulting heat converted into electricity. The bulk of the energy deposited in the first wall is in the form of X-rays (1.0-100 keV) and ions (0.1-4 MeV). In order to have a practical power plant, the first wall must be resistant to these emissions and suffer virtually no erosion on each shot. A wall candidate based on tungsten armor bonded to a low activation ferritic steel substrate has been chosen as the initial system to be studied. The choice was based on the vast experience with these materials in a nuclear environment and the ability to address most of the key remaining issues with existing facilities. This ...
2005-12-15
ANALYSIS OF ACCELERATOR BASED NEUTRON SPECTRA FOR BNCT USING PROTON RECOIL SPECTROSCOPY
Energy Technology Data Exchange (ETDEWEB)
Boron Neutron Capture Therapy (BNCT) is a promising binary treatment modality for high-grade primary brain tumors (glioblastoma multiforme, GM) and other cancers. BNCT employs a boron-10 containing compound that preferentially accumulates in the cancer cells in the brain. Upon neutron capture by {sup 10}B energetic alpha particles and triton released at the absorption site kill the cancer cell. In order to gain penetration depth in the brain Fairchild proposed, for this purpose, the use of energetic epithermal neutrons at about 10 keV. Phase I/II clinical trials of BNCT for GM are underway at the Brookhaven Medical Research Reactor (BMRR) and at the MIT Reactor, using these nuclear reactors as the source for epithermal neutrons. In light of the limitations of new reactor installations, e.g. cost, safety and licensing, and limited capability for modulating the reactor based neutron beam energy spectra alternative neutron sources are being contemplated for wider ...
1998-11-06
A revised dosimetric model of the adult head and brain
Energy Technology Data Exchange (ETDEWEB)
During the last decade, new radiopharmaceutical have been introduced for brain imaging. The marked differences of these tracers in tissue specificity within the brain and their increasing use for diagnostic studies support the need for a more anthropomorphic model of the human brain and head. Brain and head models developed in the past have been only simplistic representations of this anatomic region. For example, the brain within the phantom of MIRD Pamphlet No. 5 Revised is modeled simply as a single ellipsoid of tissue With no differentiation of its internal structures. To address this need, the MIRD Committee established a Task Group in 1992 to construct a more detailed brain model to include the cerebral cortex, the white matter, the cerebellum, the thalamus, the caudate nucleus, the lentiform nucleus, the cerebral spinal fluid, the lateral ventricles, and the third ventricle. This brain model has been included within a slightly modified version of the head model developed by ...
1996-06-01
A revised dosimetric model of the adult head and brain
International Nuclear Information System (INIS)
During the last decade, new radiopharmaceutical have been introduced for brain imaging. The marked differences of these tracers in tissue specificity within the brain and their increasing use for diagnostic studies support the need for a more anthropomorphic model of the human brain and head. Brain and head models developed in the past have been only simplistic representations of this anatomic region. For example, the brain within the phantom of MIRD Pamphlet No. 5 Revised is modeled simply as a single ellipsoid of tissue With no differentiation of its internal structures. To address this need, the MIRD Committee established a Task Group in 1992 to construct a more detailed brain model to include the cerebral cortex, the white matter, the cerebellum, the thalamus, the caudate nucleus, the lentiform nucleus, the cerebral spinal fluid, the lateral ventricles, and the third ventricle. This brain model has been included within a slightly modified version of the head model developed by ...
1996-07-21
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
