WorldWideScience
2

CENTRAL CORNEAL OPACIFICATION RESULTING FROM RECENT CHEMOTHERAPY IN CORNEAL DONORS  

UK PubMed Central (United Kingdom)

PurposeOcular surface disease following penetrating keratoplasty has been shown to increase patient morbidity and adversely affect graft survival. Five cases of dense central subepithelial...Full Text Available

2007-12-01

3

Acanthamoeba Keratitis at the King Khaled Eye Specialist Hospital  

International Nuclear Information System (INIS)

To quantify the number of cases and clinical courses of Acanthamoeba keratitis treated at the King Khaled Eye Specialist Hospital (KKESH) between December 1982 and May 2005, and to review their clinical course and response to medical and surgical therapy. Retrospective review of medical records of all patients with Acanthamoeba keratitis diagnosed by the KKESH Microbiology or Pathology or Pathology Laboratory since the opening of the hospital. During a period of over 22 years, only six cases of confirmed. Acanthamoeba keratitis were diagnosedand treated at KKESH. In two cases the diagnosis was made by corneal biopsy, while four cases required examination of a histopathology specimen obtained at the time of therapeutic keratoplasty to establish the diagnosis. One eye was cured by medical therapy, while five eyes required one (4eyes) or two (1 eye) therapeutic penetrating keratoplasty (PKP) to achieve a clinical cure. Three eyes achieved good ...

5

Central Cross-Talk in Task Switching : Evidence from Manipulating Input-Output Modality Compatibility  

Science.gov (United States)

Two experiments examined the role of compatibility of input and output (I-O) modality mappings in task switching. We define I-O modality compatibility in terms of similarity of stimulus modality and modality of response-related sensory consequences. Experiment 1 included switching between 2 compatible tasks (auditory-vocal vs. visual-manual) and between 2 incompatible tasks (auditory-manual vs. visual-vocal). The resulting switch costs were smaller in compatible tasks compared to incompatible tasks. Experiment 2 manipulated the response-stimulus interval (RSI) to examine the time course of the compatibility effect. The effect on switch costs was confirmed with short RSI, but the effect was diminished with long RSI. Together, the data suggest that task sets are modality specific. Reduced switch costs in compatible tasks may be due to special linkages between input and output ...

2010-07-01

6

Assessment of the value of various tomography modalities for diagnostic evaluation of the female genital system  

International Nuclear Information System (INIS)

The comprehensive survey explains the indications and the specific value of the modern tomographic modalities with respect to the various diagnostic issues. Numerous reproductions of CT, MRI, US scans illustrate the aspects discussed. (orig./CB)

2001-09-01

7

Microsoft Word - PressRelease Marine fuel 150711final21.doc  

Wastenet

be extremely limited or even negative due to higher maritime transport costs leading to a modal shift back to

8

Radial keratoneuritis as a presenting sign in acanthamoeba keratitis.  

Science.gov (United States)

The visual outcomes of Acanthamoeba keratitis, a rare cause of corneal infection, can be devastating. This paper reports two contact lens wearers with severe pain and photophobia who presented to the emergency room. Biomicroscopy revealed radial keratoneuritis in both individuals. Tissue culture on a nonnutrient agar plate with Escherichia coli overlay resulted in a heavy growth of Acanthamoeba. The inpatient treatment included 0.02% polyhexamethylene biguanide, chlorhexidine, neomycin/polymyxin B/bacitracin (Neosporin), and oral fluconazole, which successfully controlled the corneal infection and improvement in the best corrected visual acuity in both patients. Infection did not recur during the 12-month follow-up period. Acanthamoeba keratitis can present as radial keratoneuritis, mimicking other common corneal infections resulting in diagnostic and treatment delays. Early diagnosis and prudent treatment of Acanthamoeba keratitis are the keys to restoring vision and avoiding the ...

2011-07-01

9

Photorefractive keratectomy with mitomycin-C after corneal transplantation for keratoconus  

British Library Electronic Table of Contents (United Kingdom)

PurposeTo evaluate the efficacy of photorefractive keratectomy (PRK) for residual refractive error after penetrating keratoplasty (PKP) for keratoconus. SettingPrivate ophthalmic clinic. DesignCase series. MethodConsecutive patients who had PRK augmented with topical mitomycin-C (MMC) after PKP for keratoconus were retrospectively reviewed. Patients were divided into a a low cylinder group (refractive cylinder 6.00 D). Visual acuity, refraction, and keratometry were analyzed preoperatively and 1, 3, 6, and 12 months postoperatively. ResultsThe study comprised 47 eyes (41 patients). The spherical equivalent (SE) decreased from -4.24 D +- 3.23 (SD) preoperatively to -0.71 +- 1.03 D 12 months postoperatively in the low cylinder group and from -4.19 +- 3.54 D to -2.45 +- 3.42 D, respectively, ...

2011-01-01

10

Phacoemulsification and customized toric intraocular lens implantation in eyes with cataract and high astigmatism after penetrating keratoplasty  

British Library Electronic Table of Contents (United Kingdom)

Financial DisclosurePhacoemulsification and implantation of a hydrophilic acrylic toric intraocular lens (IOL) (T-flex 623T) with customized cylindrical power was performed in 1 eye in 3 consecutive patients with cataract and high postkeratoplasty astigmatism (range 6.75 to 8.75 diopters [D]). Twelve months postoperatively, the uncorrected distance visual acuity improved from 20/200 to 20/30 in Case 1, from 20/400 to 20/40 in Case 2, and from 20/200 to 20/25 in Case 3 and the corrected distance visual acuity was 20/25 or better in all 3 eyes. The spheroequivalent was within +-0.50 D of the intended value and the refractive astigmatism was less than 1.00 D. The corneal grafts were transparent, and the endothelial cell loss range was 6% to 12%. Rotation of the toric IOL was less than 5 degre...

2011-01-01

11

Combining anatomy and function: the path to true image fusion  

Energy Technology Data Exchange (ETDEWEB)

Modern imaging technologies visualize different aspects of disease in a non-invasive way. Considerable progress has been made in the fusion of images from different imaging modalities using software approaches. One goal of fusion software is to align anatomical and functional images and allow improved spatial localization of abnormalities. The resulting correlation of the anatomical and functional images may clarify the nature of the abnormality and help diagnose or stage the underlying disease. Whereas successful image fusion software has been developed for the brain, only limited success has been achieved for image alignment in other parts of the body. The development and current status of alternative approaches are presented. Dual-modality imaging is described with devices where two modalities are combined and mounted in a single gantry. The use of existing scanner technology ensures that no compromises are made in the ...

2001-10-01

12

Vibration testing of the I-40 bridge before and after the introduction of damage  

Energy Technology Data Exchange (ETDEWEB)

Because the bridges over the Rio Grande were to be razed, the investigators were able to introduce simulated cracks in four stages of increasing length into the structure. This paper summarizes the results of ambient and conventional, measured-input, modal analyses, performed on the undamaged structure. Also summarized are the results of conventional modal analyses performed after each stage of damage had been introduced. These tests were intended to quantify the amount of damage necessary to produce changes in the global dynamic properties of the bridge and to form a data base that can be used by other investigators to develop damage identification algorithms. Conventional modal analysis identified changes in the global dynamic properties of the structure only after the final stage of a damage.

1994-11-01

13

Coordinated synthesis of multimachine power system stabilizer using an efficient decentralized modal control (DMC) algorithm  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a new method for simultaneously selecting the power system stabilizer (PSS) parameters in multimachine power systems. Design of local output feedback power system stabilizer using local signal of the generator (e.g. speed or power) is formulated as a decentralized modal control (DMC) problem. Exact model reduction based on modal control theory is proposed to make the determination of PSS parameters highly efficient. Results obtained from the coordinated tuning of the parameters of three power system stabilizers equipped on a multimachine power system show that exact assignment of the eigenvalues associated with the poorly damped electromechanical modes can be achieved in a very efficient manner.

1986-01-01

14

Treatment of early uterine sarcomas: disentangling adjuvant modalities  

UK PubMed Central (United Kingdom)

Uterine sarcomas are a rare group of neoplasms with aggressive clinical course and poor prognosis. They are classified into four main histological subtypes in order of decreasing incidence: carcinosarcomas,...Full Text Available

15

Transarterial injection of H101 in combination with chemoembolization overcomes recurrent hepatocellular carcinoma  

UK PubMed Central (United Kingdom)

Transcatheter arterial chemoembolization (TACE) has become the standard treatment modality for unresectable hepatocellular carcinoma (HCC). Nonetheless, the clinical outcomes in patients with unresectable...Full Text Available

2011-05-14

16

Separate Mechanisms for Audio-Tactile Pitch and Loudness Interactions  

UK PubMed Central (United Kingdom)

A major goal in perceptual neuroscience is to understand how signals from different sensory modalities are combined to produce stable and coherent representations. We previously investigated interactions...Full Text Available

17

Monitoring of NK-Cell Immunotherapy using non-invasive Imaging Modalities  

UK PubMed Central (United Kingdom)

Cancer immunotherapies can be guided by cellular imaging techniques, which can identify the presence or absence of immune-cell accumulation in the tumor tissue in-vivo and in real time. This...Full Text Available

2010-08-01

18

MULTIMODALITY IMAGING: BEYOND PET/CT AND SPECT/CT  

UK PubMed Central (United Kingdom)

Multimodality imaging with PET/CT and SPECT/CT has become commonplace in clinical practice and in preclinical and basic medical research. Do other combinations of imaging modalities have a similar...Full Text Available

2009-09-01

19

Labeled lines meet and talk: population coding of somatic sensations  

UK PubMed Central (United Kingdom)

The somatic sensory system responds to stimuli of distinct modalities, including touch, pain, itch, and temperature sensitivity. In the past century, great progress has been made in understanding the...Full Text Available

2010-11-01

20

Human Lymphatic Architecture and Dynamic Transport Imaged Using Near-infrared Fluorescence12  

UK PubMed Central (United Kingdom)

BACKGROUND: Although the importance of lymphatic function is well recognized, the lack of real-time imaging modalities limits our understanding of its role in many diseases. In a phase...Full Text Available

21

Exploring the impact of a decision support intervention on vascular access decisions in chronic hemodialysis patients: study protocol  

UK PubMed Central (United Kingdom)

BackgroundIn patients with Stage 5 Chronic Kidney Disease who require renal replacement therapy a major decision concerns modality choice. However, many patients defer the decision...Full Text Available

22

Diagnostic radiology: An Anglo-American textbook of imaging  

Energy Technology Data Exchange (ETDEWEB)

This multiauthored text is aimed particularly toward the resident or registrar training in diagnostic radiology. This is a text book on the entire scope of diagnostic imaging. It includes techniques and imaging modalities of all the systems, head, face and neck. The book covers the entire gamut of diagnostic radiology.

1986-01-01

23

Characteristics of common solid liver lesions and recommendations for diagnostic workup  

UK PubMed Central (United Kingdom)

Due to the widespread clinical use of imaging modalities such as ultrasonography, computed tomography and magnetic resonance imaging (MRI), previously unsuspected liver masses are increasingly being...Full Text Available

2009-07-14

24

Bilateral Pneumothorax and Subcutaneous Emphysema following Endoscopic Retrograde Cholangiopancreatography: A Rare Complication  

UK PubMed Central (United Kingdom)

Endoscopic Retrograde Cholangiopancreatography (ERCP) is a widely used diagnostic and therapeutic modality in the management of biliary and pancreatic disease. Some of the complications of the procedure,...Full Text Available

2010-01-01

25

Activation of Cytotoxic and Regulatory Functions of NK Cells by Sindbis Viral Vectors  

UK PubMed Central (United Kingdom)

Oncolytic viruses (OVs) represent a relatively novel anti-cancer modality. Like other new cancer treatments, effective OV therapy will likely require combination with conventional treatments. In order...Full Text Available

26

A Novel Information Retrieval Model for High-Throughput Molecular Medicine Modalities  

UK PubMed Central (United Kingdom)

Significant research has been devoted to predicting diagnosis, prognosis, and response to treatment using high-throughput assays. Rapid translation into clinical results hinges upon efficient access...Full Text Available

27

A Comparison of intra-oral digital imaging modalities: Charged Couple Device versus Storage Phosphor Plate  

UK PubMed Central (United Kingdom)

BackgroundThis in vitro study was conducted to compare the accuracy of two digital image receptors in identifying the location of tip of a fine endodontic file and radiographic apex...Full Text Available

2010-11-01

28

Vibrations of circular cylindrical shells  

Science.gov (United States)

An exact solution method for the free vibration problem of thin circular cylindrical shells is presented. The differential equations of motion are solved directly with the use of simple Fourier series as the modal displacement functions. Stokes' transformation is exploited to obtain correct series expressions for the derivatives of the Fourier series. From this method an explicit expression of the exact frequency equation can be obtained for any kind of boundary conditions. The accuracy of the present method is checked against available data. The proposed method is then used to find the modal characteristics of the thermal liner of the Fast Test Reactor (FTR). The numerical results obtained are compared with finite element method solutions. (auth)

1975-07-01

29

Refinement of conventional PSS design in multimachine system by modal analysis  

Science.gov (United States)

The design of the lead/lag network in a conventional power system stabilizer (PSS) is intended to provide the correct compensation in order to obtain an electrical torque component in phase with the speed variation. It is shown that, for a multimachine system, the conventional design analysis and synthesis tend to oversimplify the system representation and hence the interaction effects. A more rigorous approach is preferred considering four torque (or power) components instead of the conventional single component. Based on modal analysis, the significance of these other components is revealed, the more comprehensive treatment using a generalized multimachine representation is justified and a reliable means for optimizing the PSS parameters is explained.

1993-05-01

30

Clinical magnetic resonance imaging with nuclear medicine correlation  

Energy Technology Data Exchange (ETDEWEB)

The current role of magnetic resonance imaging (MRI) in different organ systems is discussed and compared to nuclear medicine and to other available clinical diagnostic modalities. The value of optimizing radiofrequency pulse sequence selection to provide additional tissue characterization is also described. The results of nuclear medicine and MRI studies in 56 patients are compared to evaluate the clinical diagnostic contribution of each imaging modality for various pathological processes. In addition, the state-of-the-art MRI systems and future development in MRI technology with its potential contribution is defined.

1985-08-01

31

Virtual colonoscopy (CT colonography) in the identification of colorectal cancer. A prospective study in symptomatic patients  

International Nuclear Information System (INIS)

Aim of this study was to evaluate the sensitivity of virtual colonoscopy (CT colonography) in the identification of colorectal cancer and to define the limitations and the advantages of this imaging modality, as well as indications to the examination. It was examined prospectively 62 symptomatic patients aged 36 to 82 years (28 women and 34 men). All patients underwent both conventional and virtual colonoscopy on the same day; the conventional examination allowed exploration of the entire colon. Conventional colonoscopy identified 89 lesions 3-50 mm in diameter, namely 84 benign and 5 malignant lesions. No lesions were identified in 12 patients. CT colonography identified 52 of the 89 lesions, with 57.1% diagnostic accuracy. They were 11 false positives (82.5% positive predictive value and 52.2% specificity) and 37 false negatives (24.5% negative predictive value and 58.4% sensitivity). Sensitivity was significantly higher (85.7%) for polyps #>=# 1 cm. Virtual ...

2000-06-01

32

Comparative evaluation of similarity measures for the rigid registration of multi-modal head images  

Energy Technology Data Exchange (ETDEWEB)

Image registrations that are based on similarity measures simply adjust the parameters of an appropriate spatial transformation model until the similarity measure reaches an optimum. The numerous similarity measures that have been proposed in the past are differently sensitive to imaging modality, image content and differences in the image content, selection of the floating and target image, partial image overlap, etc. In this paper, we evaluate and compare 12 similarity measures for the rigid registration. To study the impact of different imaging modalities on the behavior of similarity measures, we have used 16 CT/MR and 6 PET/MR image pairs with known 'gold standard' registrations. The results for the PET/MR registration and for the registration of CT to both rectified and unrectified MR images indicate that mutual information, normalized mutual information and the entropy correlation coefficient are the most accurate ...

2007-09-21

33

Vertical array receptions of the Heard Island transmissions  

Energy Technology Data Exchange (ETDEWEB)

The Heard Island Feasibility Test (HIFT) demonstrated that coded acoustic signals could be detected at ranges up to 18,000 km with currently available source technology. This paper describes one component of the HIFT where a large aperture vertical line array was deployed to record the signals transmitted from Heard Island. We have performed four analysis Of the VLA receptions, of the Heard Island signals. All four suggest the presence of higher order modes. The frequency- vertical wavenumber analysis and the modal beamforming indicate that mode 3 has the highest amplitude while the modal fitting suggests that made 5--6 are largest. It is difficult to resolve the differences since the SNR at the VLA, nearly 18,000 km with a transmission loss of around 145 dB, is quite low. Individual arrivals could not be distinguished because of the long integration time necessitated by the low SNR.

1993-03-23

34

Targeted drug delivery under MRI guidance  

British Library Electronic Table of Contents (United Kingdom)

The main goal of local drug delivery is to increase the concentration of a specific therapeutic agent in a target tissue with minimal nontarget distribution. Compared to systemic therapy, local drug delivery provides a high level of therapeutic efficacy with minimal systemic effects. The current primary imaging modality for drug delivery has been x-ray angiography, but it has major limitations including anatomical ambiguity and inability to visualize the targeted tissues. Due to these inherent problems, MR guidance has been explored as an alternative imaging modality for guiding and monitoring of drug therapy. Recently, interventional MR (XMR) systems have been implemented that have both dual x-ray and MRI capabilities in a single suite and allow for real-time interventional procedures to ...

2008-01-01

35

Radial velocities, dynamics of stars and nebulosities with GAIA and VLT-GIRAFFE  

CERN Document Server

This document is divided in two parts. The first part deals with the radial velocities (RV) distributions for B-type stars and nebulosities observed with the VLT-GIRAFFE in the Large and Small Magellanic Clouds towards the open clusters NGC2004 and NGC330. Thanks to the resolution of GIRAFFE spectra, we found that the RV distribution for the nebulosities in the LMC is bi-modal. This bi-modality can be interpreted, in term of dynamics, by the expansion of the LMC4 superbubble. The second part deals with the GAIA space mission and the determination of the radial velocities by using Radial Velocity Spectrometer (RVS) spectra. The methods to determine the radial velocities are presented as well as preliminary results on simulated RVS spectra.

2008-01-01

36

Perceptual congruency of audio-visual speech affects ventriloquism with bilateral visual stimuli  

British Library Electronic Table of Contents (United Kingdom)

Many studies on multisensory processes have focused on performance in simplified experimental situations, with a single stimulus in each sensory modality. However, these results cannot necessarily be applied to explain our perceptual behavior in natural scenes where various signals exist within one sensory modality. We investigated the role of audio-visual syllable congruency on participants? auditory localization bias or the ventriloquism effect using spoken utterances and two videos of a talking face. Salience of facial movements was also manipulated. Results indicated that more salient visual utterances attracted participants? auditory localization. Congruent pairing of audio-visual utterances elicited greater localization bias than incongruent pairing, while previous studies have repor...

2011-01-01

37

Particle Swarm Optimization and gravitational wave data analysis: Performance on a binary inspiral testbed  

CERN Document Server

The detection and estimation of gravitational wave (GW) signals belonging to a parameterized family of waveforms requires, in general, the numerical maximization of a data-dependent function of the signal parameters. Due to noise in the data, the function to be maximized is often highly multi-modal with numerous local maxima. Searching for the global maximum then becomes computationally expensive, which in turn can limit the scientific scope of the search. Stochastic optimization is one possible approach to reducing computational costs in such applications. We report results from a first investigation of the Particle Swarm Optimization (PSO) method in this context. The method is applied to a testbed motivated by the problem of detection and estimation of a binary inspiral signal. Our results show that PSO works well in the presence of high multi-modality, making it a viable candidate method for further applications in GW data analysis.

2010-01-01

38

PET and MRI in cardiac imaging: from validation studies to integrated applications  

International Nuclear Information System (INIS)

Positron emission tomography (PET) is the gold standard for non-invasive assessment of myocardial viability and allows accurate detection of coronary artery disease by assessment of myocardial perfusion. Magnetic resonance imaging (MRI) provides high resolution anatomical images that allow accurate evaluation of ventricular structure and function together with detection of myocardial infarction. Potential hybrid PET/MR tomography may potentially facilitate the combination of information from these imaging modalities in cardiology. Furthermore, the combination of anatomical MRI images with the high sensitivity of PET for detecting molecular targets may extent the application of these modalities to the characterization of atherosclerotic plaques and to the evaluation of angiogenetic or stem cell therapies, for example. This article reviews studies using MRI and PET in parallel to compare their performance in cardiac applications together with the ...

2009-03-01

39

Moving train loads identification on a continuous steel truss girder by using dynamic displacement influence line method  

British Library Electronic Table of Contents (United Kingdom)

This paper presents a dynamic displacement influence line method for moving load identification on bridge. The finite element model of Poyang Lake continuous truss bridge-train systems is established and the dispersed modal shapes are acquired by modal analysis. Multi-axle moving train loads are identified with simulated annealing genetic algorithm by minimizing the errors between the measured displacements and the reconstructed displacements from the identified moving loads. In the identification process, the dynamic displacement influence line technique is used to calculate the time history displacement responses of the bridge to avoid solving equations of motion of the bridge repetitively. Several important parameters of the bridge-train system are discussed to investigate their effects...

2011-01-01

40

Modal Meinongianism and fiction: the best of three worlds  

British Library Electronic Table of Contents (United Kingdom)

We outline a neo-Meinongian framework labeled as Modal Meinongian Metaphysics (MMM) to account for the ontology and semantics of fictional discourse. Several competing accounts of fictional objects are originated by the fact that our talking of them mirrors incoherent intuitions: mainstream theories of fiction privilege some such intuitions, but are forced to account for others via complicated paraphrases of the relevant sentences. An ideal theory should resort to as few paraphrases as possible. In Sect.?1, we make this explicit via two methodological principles, called the Minimal Revision and the Acceptability Constraint. In Sect.?2, we introduce the standard distinction between internal and external fictional discourse. In Sects.?3?5, we discuss the approaches of (traditional) Meinongia...

2011-01-01

41

From the podium to the PC: a study on various modalities of lecture delivery within an undergraduate basic pharmacology course  

British Library Electronic Table of Contents (United Kingdom)

The need to evolve with our ever-changing student bodies has never been as great as it is today, particularly given the advanced technological aptitude of today's students. This retrospective study evaluates student outcomes as they relate to overall course score and composite quiz and examination scores from a basic pharmacology course taught over three separate semesters using three different lecture delivery modalities: traditional in-class; blended; and online-only. A total of 48 students from a US university's health sciences bachelor degree programme enrolled in one of these three sections between 2009 and 2010. A one-way analysis of variance test with Tukey's honestly significant difference post hoc testing was utilized to determine if any statistical difference existed between the ...

2011-01-01

42

Fetal magnetic resonance imaging of the brain: technical considerations and normal brain development  

International Nuclear Information System (INIS)

Fetal MRI examines non-invasively the unborn fetus. Ultrafast MRI sequences effectively suppress fetal motion. Multiple case reports and studies have shown that fetal MRI is particularly helpful in the evaluation of the central nervous system. The high contrast-to-noise ratio, the high spatial resolution, the multiplanar capabilities, the large field of view and the simultaneous visualisation of fetal and maternal structures have proven to be advantageous. Fetal MRI is particularly helpful in the evaluation of the normal and pathological development of the brain. Despite the fact that no side effects have been reported or are to be expected, the use of MRI during pregnancy is still limited to the second and third trimester of pregnancy. Magnetic resonance imaging contrast media are not to be used as it passes the placenta. Ultrasound remains the primary screening modality for fetal pathology; fetal MRI can serve as an adjunct or second-line imaging ...

2002-08-01

43

FFTF scale-model characterization of flow-induced vibrational response of reactor internals  

International Nuclear Information System (INIS)

As an integral part of the Fast Test Reactor Vibration Program for Reactor Internals, the flow-induced vibrational characteristics of scaled Fast Test Reactor core internal and peripheral components were assessed under scaled and simulated prototype flow conditions in the Hydraulic Core Mockup. The Hydraulic Core Mockup, a 0.285 geometric scale model, was designed to model the vibrational and hydraulic characteristics of the Fast Test Reactor. Model component vibrational characteristics were measured and determined over a range of 36 percent to 111 percent of the scaled prototype design flow. Selected model and prototype components were shaker tested to establish modal characteristics. The dynamic response of the Hydraulic Core Mockup components exhibited no anomalous flow-rate dependent or modal characteristics, and prototype response predictions were adjudged acceptable.

44

Development of a Full Body CAD Dataset for Computational Modeling: A Multi-modality Approach  

British Library Electronic Table of Contents (United Kingdom)

The objective of this study was to develop full body CAD geometry of a seated 50th percentile male. Model development was based on medical image data acquired for this study, in conjunction with extensive data from the open literature. An individual (height, 174.9?cm, weight, 78.6???0.77?kg, and age 26?years) was enrolled in the study for a period of 4?months. 72 scans across three imaging modalities (CT, MRI, and upright MRI) were collected. The whole-body dataset contains 15,622 images. Over 300 individual components representing human anatomy were generated through segmentation. While the enrolled individual served as a template, segmented data were verified against, or augmented with, data from over 75 literature sources on the average morphology of the human body. Non-Uniform Rational...

2011-01-01

45

Study of modal parameters and vibration signatures of notched concrete prisms  

International Nuclear Information System (INIS)

In the present study, vibration tests have been carried out on notched concrete prisms. The tests have been conducted to study modal parameters and vibration signatures in order to enhance the knowledge of monitoring concrete structures. Notch (artificially introduced crack) of constant widths and varying depths has been introduced in the concrete prisms at different locations. The specimens have been subjected to impact excitations by dropping a specific weight from a fixed height and at a particular location. The natural frequencies of notched and intact prisms have been experimentally measured. The frequency response functions (FRF) as obtained from multichannel pulse analyzer have been synthesized to evaluate the fundamental mode shape of vibration of the prisms by a curve fitting method. These curves have been further post-processed to obtain the modal curvature values. Pattern Recognition Scheme is applied to synthesize vibration ...

2006-03-01

46

Metastatic Ewing's sarcoma to the skull: CNS involvement excluded by MRI  

International Nuclear Information System (INIS)

A case of metastatic Ewing's sarcoma to the skull is presented, demonstrating the superiority of magnetic resonance imaging over other imaging modalities to exclude CNS involvement. Precise delineation of different tumor components in extradural location contained in an intact dural rim together with compressed cortex showing no signs of tumorous involvement constituted an MRI appearance allowing us to exclude tumor outgrowth into the brain. (orig.).

47

Intensive combined modality therapy including low-dose TBI in high-risk Ewing's sarcoma patients  

International Nuclear Information System (INIS)

Twenty-four high-risk Ewing's sarcoma patients were treated on an intensive combined modality protocol including low-dose fractionated total body irradiaiton (TBI) and autologous bone marrow infusion (ABMI). Twenty patients (83%) achieved a complete clinical response to the primary and/or metastatic sites following induction therapy. The median disease-free interval was 18 months, and nine patients remain disease-free with a follow-up of 22 to 72 months. Local failure as a manifestation of initial relapse occurred in only three patients (15%), each having synchronous distant failure. Eight patients failed initially with only distant metastases, usually within 1-2 years following a complete clinical response. Two patterns of granulocyte recovery following consolidative therapy (including TBI and ABMI) were recognized. The time to platelet recovery was different for the groups with early and late granulocyte recovery. Patients with late recovery did not tolerate ...

48

Flux mapping system for TAPS 3 and 4: software perspective  

International Nuclear Information System (INIS)

The Flux Mapping System (FMS) of 540 MWe PHWR is a system, which is first of its kind used in Indian PHWRs. It is used to compute a detailed flux/power distribution of the reactor core using modal synthesis method .The paper brings out the high availability features of FMS and the software design philosophy. The paper emphasizes on framework based reusable architectural design, which simplifies and speeds up the development of data acquisition systems. (author)

2010-02-01

49

Diagnostic imaging of the acutely injured patient  

Energy Technology Data Exchange (ETDEWEB)

This book provides an analysis of pathophysiologic concepts of trauma and reviews the effectiveness of the available imaging modalities in acute trauma of various organ system. Topics covered are chest injuries; abdominal trauma; fractures of long bones; the foot and ankle; the knee; hand and wrist; the elbow; the shoulder; the pelvis hips; the spine; the skull and facial trauma and the clinical assessment of multiple injuries patients. Comparative evaluation of diagnostic techniques of radiography is discussed. Normal anatomy and bone fractures along with soft-tissue injuries are described.

1985-01-01

50

Computed tomography of the urinary bladder. Clinical application of the olive oil-filled method  

Energy Technology Data Exchange (ETDEWEB)

Out of one hundred cases of the urinary bladder abnormalities examined by this method, CT staging and pathological correlations were investigated in 61 cases of the urinary bladder neoplasms. Accuracy of CT staging was 87% in this series with possible exception of 6 cases involving the bladder base and dome. CT scan using this method is the most reliable procedure to determine the treatment modalities of the urinary bladder tumors.

1982-01-01

51

An online monitoring system for nuclear waste storage  

International Nuclear Information System (INIS)

We propose a system for the on-line monitoring of short and medium term radioactive waste repositories. Such a system is distributed, fine-grained, robust, reliable, and must be based on low-cost components. It could, in principle, open new perspectives on the modality of waste packaging and storage. In particular we propose to employ a new family of cheap and powerful micro sensors to be placed in shape of a fine grid around each single drum. (authors)

2009-06-07

52

The national plan of fight against greenhouse effect; Le plan national de lutte contre l'effet de serre  

Energy Technology Data Exchange (ETDEWEB)

France has committed herself to keep in 2010 the same levels of greenhouse gas emissions as those of 1990, i.e. 144 millions of tons of carbon equivalent (MtCe). However, taking into account the existing pollution abatement measures and the measurements performed so far, the greenhouse gases level should reach 160 MtCe in 2010. Therefore, the inter-ministry commission on greenhouse effect decided on November 27, 1998 to elaborate a new national plan of fight against greenhouse effect. The elaboration of the new plan has fallen under the responsibility of the inter-ministry mission of greenhouse effect (MIES). The new plan was presented by the prime minister, L. Jospin, on January 19, 2000. This document summarises the content of the new plan: architecture (modalities of elaboration, content), measures for the reduction of greenhouse gas emissions (industry, transportation sector, buildings, agriculture-forestry, wastes valorization, development of renewable ...

2000-07-01

53

Nitrogen Requirements and Balance of Protected Cucumber in Coastal Lebanon  

International Nuclear Information System (INIS)

Protected cultures are widespread along the Lebanese narrow coastline, encouraged by mild winter conditions. Although one of the most intensive production systems, water and nutrients managements are mostly empirical, based on the experience of the grower himself or of his workers. So far, water has been available in Lebanon, but it will become scarce within ten years. The conservation of water quality by a rational addition of nutrients is particularly relevant to protected cultures. This is important as greenhouses are developed on imported shallow soils that could be fragile and highly vulnerable to pollution. Sound management includes the amount and the forms of fertilizers as well as the modality of fertigation. An experiment was conducted during two spring seasons in a location along the northern coast in a typical unheated greenhouse. The cucumber response to two frequencies and modalities of fertigation was followed: continuous T2C and ...

2003-10-01

54

MRI, CT, sonography and thallium-technetium subtraction scintigraphy for the detection of parathyroid disease: a four-year experience  

International Nuclear Information System (INIS)

Sonography, subtraction scintigraphy, computed tomography and MRI were compared in 100 patients who had surgery 105 times for hyperparathyroidism (HPT). Surgical and pathological data were available for all operations. A total of 105 MR, 77 CT, 84 sonograms and 70 subtraction scintigrams were performed. The ability of the imaging modalities, individually and in combination, to detect HPT, histology, size, concomitant thyroid disease and location of the diseased glands has been evaluated. For primary HPT, sensitivity ranged from 68% for MRI to 40% for scintigraphy but was much lower for tertiary HPT with all modalities. The ability to identify diseased glands was strongly size dependent for all methods. If patients had had previous neck surgery, the most sensitive methods were MRI and scintigraphy and this also held true for patients with concomitant thyroid disease and ectopically located glands. The findings presented suggest that while ...

55

Limitations of traveling wave relaying for overhead EHV transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Limitations of traveling wave relaying schemes for protection of overhead extra-high voltage transmission lines are investigated. A method of analysis of traveling wave phenomena for three phase transmission lines is developed in which the interdependent phase voltages and currents are decoupled into their modal counterparts, which are approximately independent. A time domain digital simulation program is used to solve the modal transmission line equations to obtain the fault induced traveling waves detected at the relay location. The frequency dependence of the aerial modes is ignored but their losses are included. A lumped element analysis method, originally developed for transient analysis of lossy coaxial cables, is adapted here to obtain approximate solution for the fault induced traveling waves of the ground mode. Excellent agreement is found between the results obtained by this method and frequency domain methods. This time-domain method ...

1986-01-01

56

Complications of gallstone disease: Mirizzi syndrome, cholecystocholedochal fistula, and gallstone ileus.  

Science.gov (United States)

Gallstone is a common disease with a 10% prevalence in the United States and Western Europe. However, it is only symptomatic in 20-30% of patients, with biliary pain "colic" being the most common symptom. Complications of asymptomatic gallstone disease are generally rare, with an incidence of <1 %/yr. The most common complications of gallstone disease are acute cholecystitis, acute pancreatitis, ascending cholangitis, and gangrenous gallbladder. Less frequent complications include Mirizzi syndrome, cholecystocholedochal fistula, and gallstone ileus. Mirizzi syndrome and cholecystocholedochal fistula are two manifestations of the same process that starts with impaction of a gallstone in the gallbladder neck that results in obstruction of the bile duct, causing jaundice. The gallstone may erode into the bile duct, causing cholecystocholedochal fistula. Gallstone ileus refers to small bowel obstruction resulting from the impaction of one or more gallstones after they have migrated ...

2002-02-01

57

An evaluation of low-dose single-slice helical CT in pulmonary CT scan  

International Nuclear Information System (INIS)

Objective: To investigate the feasibility of low-dose single-slice helical CT in pulmonary CT scan and evaluate the clinical application. Methods: Thirteen cases were selected out of 132 cases, in which low-dose (50mAs) single-slice helical CT scan of chest was performed. This set of cases included 7 cases of multiple metastatic nodules; 3 of solitary pulmonary, nodule; and 3 of pulmonary patchy lesions. Regular dose (170mAs) CT scan was also performed on all those patients. The regular dose and low dose CT scan were compared on sensitivity of detecting the lesions; the performance in demonstrating the details of the abnormalities; and the capability of revealing the segmental bronchi as well. Results: The same number and size of the pulmonary nodules were revealed with scan modalities loaded with different doses. No significant difference in demonstrating the details of the nodules and the segmental bronchi was found between both modalities ...

2006-04-01

58

Usefulness of MRI in diagnosis of hepatocellular carcinoma (HCC)  

Energy Technology Data Exchange (ETDEWEB)

Sixty-six cases of histologically proven hepatocellular carcinomas (HCC) were studied by MRI. Detectability was better by MRI than by CT, especially in the tumor under 2 cm in diameter. The capsule was detected in all cases of HCC over 3 cm in diameter. The capsule was able to be diagnosed only by dynamic MRI study in some cases. High intensity on the T1-weighted image and iso or low intensity on the T2-weighted image suggested that the nodule was adenomatous hyperplasi (AH) or well differentiated HCC. MRI is concluded to be an essential modality in the diagnosis of HCC. (author).

1992-06-01

59

The application of Geant4 simulation code for brachytherapy treatment  

CERN Document Server

Brachytherapy is a radiotherapeutic modality that makes use of radionuclides to deliver a high radiation dose to a well-defined volume while sparing surrounding healthy structures. At the National Institute for Cancer Research of Genova a High Dose Rate remote afterloading system provides Ir(192) endocavitary brachytherapy treatments. We studied the possibility to use the Geant4 Monte Carlo simulation toolkit in brachytherapy for calculation of complex physical parameters, not directly available by experiment al measurements, used in treatment planning dose deposition models.

2000-01-01

60

Shell effects in the symmetric-modal fission of pre-actinide nuclei  

International Nuclear Information System (INIS)

Mass distributions of fragments in the low-energy fission of nuclei from "1"8"7Ir to "2"1"3At have been analysed. This analysis has shown that shell effects in symmetric-mode fragment mass yields from the fission of pre-actinide nuclei could be described if one assumes the existence of two strongly deformed neutron shells in the arising fragments with neutron numbers N_1#approx#52 and N_2#approx#68. A new method has been proposed for quantitatively describing the mass distributions of the symmetric fission mode for pre-actinides with A#approx#180-220. (orig.)

1998-09-21

61

Review of electron beam therapy physics  

Energy Technology Data Exchange (ETDEWEB)

For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)

2006-07-07

62

Periosteal Ewing's sarcoma  

International Nuclear Information System (INIS)

Periosteal Ewing's sarcoma is an uncommon, but well documented origin of this malignant condition with radiography signs, different from intramedullary growing tumours. Imaging modalities like CT or MRI supply proof of macroscopically intact endosteal cortical surface and free medullary cavity in long bones affected by this periosteal type of malignancy. Definite confirmation is valid after a careful microscopic investigation of the resected specimen. The prognosis of this type of Ewing's sarcoma may be favourable than that of the central type. Early diagnosis and therapy are thus essential. A clinical survey of six observations is given. (orig.).

63

PET/CT-guided interventional procedures: rationale, justification, initial study, and research plan  

International Nuclear Information System (INIS)

Positron-emission tomography (PET) and PET/CT (computed tomography) are becoming increasingly important for diagnosis and treatment of cancer. Clinically relevant changes can sometimes be seen on PET that are not seen on other imaging modalities. However, PET is not suitable for guiding biopsy as the images are not obtained in real-time. Therefore, our research group has begun developing a concept for PET/CT-guided interventional procedures. This paper presents the rationale for this concept, outlines our research plan, and includes an initial study to evaluate the relative sensitivity of CT and PET/CT in detecting suspicious lesions. (orig.)

2007-06-01

64

Oncogenic transformation produced by agents and modalities used in cancer therapy and its modulation  

International Nuclear Information System (INIS)

The long-term survival of certain patients after treatment with radiation or chemotherapeutic agents has allowed the realization that agents that effectively control cancer in the human subject may also possess an oncogenic potential, resulting in secondary malignancies in a significant proportion of surviving patients. A quantitative assessment of the oncogenic effects of these agents at a cellular level is important, as is information on conditions and agents that may effectively alter the development of the neoplastic state. Cell culture systems where the neoplastic transformation of cells can be scored after exposure to carcinogens offer powerful tools for evaluating the oncogenic potential of radiation and chemotherapeutic agents.

1982-01-01

65

Lung cancer screening program using annual chest radiographs with computed radiography (FCR)  

Energy Technology Data Exchange (ETDEWEB)

In the Wajima lung cancer screening program conducted under the auspices of Kanazawa University Hospital, Fuji Computed Radiography (FCR) was utilized in a new chest radiography trial. The results of the screening program are that the necessity of repeat examinations due to poor image quality are less common and the method enables detection of small pulmonary nodular shadows which are possibly candidates for surgery. Oblique chest X-ray with FCR is remarkably effective for the detection and the identification of small lesions. However, the disadvantage of slow processing and high cost must be fully satisfied if FCR is to become a new imaging modality for mass screening.

1987-08-01

66

Lung cancer screening program using annual chest radiographs with computed radiography (FCR)  

International Nuclear Information System (INIS)

In the Wajima lung cancer screening program conducted under the auspices of Kanazawa University Hospital, Fuji Computed Radiography (FCR) was utilized in a new chest radiography trial. The results of the screening program are that the necessity of repeat examinations due to poor image quality are less common and the method enables detection of small pulmonary nodular shadows which are possibly candidates for surgery. Oblique chest X-ray with FCR is remarkably effective for the detection and the identification of small lesions. However, the disadvantage of slow processing and high cost must be fully satisfied if FCR is to become a new imaging modality for mass screening. (author).

1987-01-01

67

Intra-arterial injection of 131-I-Lipiodol in the treatment of hepato-cellular carcinoma; Lipiocis et carcinome hepato-cellulaire  

Energy Technology Data Exchange (ETDEWEB)

The incidence of hepatocellular carcinoma (HCC) is increasing in developed countries and the general status of HCC patients is now by far better than a few years ago, allowing physicians to propose some different treatments of these patients. Among these treatments, intra-arterial injection of 131-iodine-labelled Lipiodol could be used in palliative, curative or adjuvant settings. After a brief summary of the modalities of this treatment, requiring the collaboration of Gastro-enterologists, Oncologists, Radiologists and Nuclear Medicine physicians, the different possibilities of therapeutic uses of this new approach are described and an outlook of these developments is proposed. (author)

2001-11-01

68

Interplay between the ray and mode effects in electromagnetic behavior of small-size hemielliptic dielectric lenses  

CERN Document Server

Focusing and resonance properties of two-dimensional small-size hemielliptic lenses made of different materials are studied numerically in order to estimate the influence of internal reflections on the radiation characteristics of dielectric lens antennas. Accuracy of in-house made algorithms based on combination of geometrical and physical optics and FDTD in the analysis of optical and modal effects in the behavior of such lenses is tested by comparison with the exact solution obtained using the Muller boundary integral equations. The range of applicability for the approaches is discussed.

2010-01-01

69

Computed tomography in spinal osteoblastoma  

International Nuclear Information System (INIS)

In order to stress the role of computed tomography (CT) in the evaluation of benign spinal osteoblastoma, the authors examined by CT 10 patients with surgically and histologically proved osteoblastomas of the spine. Basing on surgical and histopathological findings CT proved to be a very important method for attesting the presence of the tumors (usually showed by radiographic examination), and specially for their staging and follow-up. CT in fact showed the real extent of the tumor into the spinal canal and towards the paraspinal soft tissues, and allowed the aerly detection of post surgical relapses. The authors conclude that CT is a primary diagnostic modality for preoperative planning and follow-up of benign osteoblastoma.

1986-01-01

70

Combined Modality Treatment for Prostate Cancer With Dynamic Adaptive Radiation Therapy Using Four-Dimensional Image-Guided Intensity-Modulated Radiation Therapy and Brachytherapy  

British Library Electronic Table of Contents (United Kingdom)

Prostate cancer can be successfully treated using dynamic adaptive external beam radiation techniques along with interstitial brachytherapy to deliver curative therapies with low urinary, rectal and erectile function morbidity. Through the use of sophisticated, state-of-the art radiographic imaging for staging and treatment planning, a precise, individual design for treatment is accomplished. Symptom management and patient education are of paramount importance and are integrated throughout the treatment process.

2009-01-01

71

Cerebral and meningeal manifestations of AIDS: Sensitivity of CT and T sub 2 -weighted MR (129 patients). Zerebrale und meningeale Manifestation des AIDS: Sensitivitaet von CT und T sub 2 -gewichteter MRT (129 Patienten)  

Energy Technology Data Exchange (ETDEWEB)

We studied 129 AIDS patients with suspected or proved intracranial manifestations of the disease. The purpose of this study was to compare the diagnostic sensitivity of unenhanced and contrast enhanced CT and unenhanced T{sub 2}-weighted MR. Thus, in 20% of our patients MR but not CT was diagnostic. In another 20% MR provided additional diagnostic information. In conclusion, MR is recommended as the imaging modality of choice in AIDS patients with non-conclusive cranial CT. (orig./GDG).

1990-09-01

72

Back pain in the osteoporotic individual: A physiatric approach  

British Library Electronic Table of Contents (United Kingdom)

Back pain from osteoporosis is commonly related to compression fractures. The patient with vertebral compression fractures additionally suffers from an ongoing risk of recurrent fractures and postural abnormalities that can result in impaired respiratory function, leading to increased risk of morbidity. Weakened back muscles, especially the back extensor group, are felt to contribute significantly to this risk. The combination of pharmacologic and nonpharmacologic interventions, through physical activity, exercise, and modalities, are potential interventions that could be used to help reduce the pain of osteoporotic compression fractures as well as potentially reducing recurrent fracture rates.

2011-01-01

73

A solution to add digital signatures to medical images according to the DICOM standard: embedded systems  

International Nuclear Information System (INIS)

Radiology departments often underestimate the importance of protecting medical data during transmission, including the precautions taken to ensure data protection. In teleradiology, transmitted as well as stored patient data have to be signed digitally according to the currently valid regulation (Roentgenverordnung, RoeV). The DICOM standard facilitates a digital signature. So far, medical image manufacturers only announced to support this security feature. We introduce a solution that extends the feature of digital signing to older modalities. (orig.)

2005-01-01

74

The role of MRI in the diagnosis of recurrent/persistent carpal tunnel syndrome: A radiological and intra-operative correlation  

British Library Electronic Table of Contents (United Kingdom)

MRI (Magnetic resonance imaging) has been widely used in the diagnosis of primary carpal tunnel syndrome (CTS). However, it has had limited clinical application in diagnosing persistent or recurrent CTS. We aimed to investigate the efficacy of this imaging modality in patients who had previously undergone open carpal tunnel release without relief of symptoms, and assess the correlation of MRI with intra-operative findings upon re-exploration. MRI studies were performed on 17 wrists (16 patients) presenting with recurrent/persistent symptoms and signs of CTS in whom repeat nerve conduction studies were also performed. Surgical re-exploration was undertaken on 16 wrists in which a 100% correlation was noted between MRI and intra-operative findings of an incompletely released or re-grown tran...

2011-01-01

75

Surgical navigation using audio feedback.  

Science.gov (United States)

Current medical visualization technology intended for positional guidance in surgical applications may only ever have limited utility in the operating room due to the preexisting visual requirements of surgical practice. Additionally, visual systems impose limits as a result of their high latency, poor image resolution, problems with stereopsis and physical strain upon the user. Audio technology is relatively unexamined in the broad range of available methodologies for medical devices. The potential to translate surgical instrument position into audio feedback presents a novel solution to the human factors and engineering problems faced by visual display technology because audio technology employs a rich and as yet unburdened sensory modality. We describe an experimental system we have developed for investigating this new interface design approach using commercially available hardware. PMID:10173065

1997-01-01

76

Solution state hybridization detection using time-resolved fluorescence anisotropy of quantum dot-DNA bioconjugates  

British Library Electronic Table of Contents (United Kingdom)

In this Letter, we demonstrate the application of time-resolved fluorescence anisotropy measurements to detect solution state hybridization of streptavidin conjugate (CdSe)ZnS quantum dots (QD). The study was performed on samples containing 10nM QD incubated with 800nM DNA. We show that the rotational correlation time of QD-DNA constructs increases significantly upon hybridization with values of 330ns (QD-ssDNA) and 1.3ms (QD-dsDNA), corresponding to a diameter of 14nm and 23nm respectively. The present study opens a new modality for hybridization detection using quantum dots.

2010-01-01

77

Shell effects in the symmetric-modal fission of pre-actinide nuclei  

Energy Technology Data Exchange (ETDEWEB)

Mass distributions of fragments in the low-energy fission of nuclei from {sup 187}Ir to {sup 213}At have been analysed. This analysis has shown that shell effects in symmetric-mode fragment mass yields from the fission of pre-actinide nuclei could be described if one assumes the existence of two strongly deformed neutron shells in the arising fragments with neutron numbers N{sub 1}{approx}52 and N{sub 2}{approx}68. A new method has been proposed for quantitatively describing the mass distributions of the symmetric fission mode for pre-actinides with A{approx}180-220. (orig.) 28 refs.

1998-09-21

78

Robotics in pediatric surgery: perspectives for imaging  

International Nuclear Information System (INIS)

Robotic surgery will give surgeons the ability to perform essentially tremorless microsurgery in tiny spaces with delicate precision and may enable procedures never before possible on children, neonates, and fetuses. Collaboration with radiologists, engineers, and other scientists will permit refinement of image-guided technologies and allow the realization of truly remarkable concepts in minimally invasive surgery. While robotic surgery is now in clinical use in several surgical specialties (heart bypass, prostate removal, and various gastrointestinal procedures), the greatest promise of robotics lies in pediatric surgery. We will briefly review the history and background of robotic technology in surgery, discuss its present benefits and uses and those being explored, and speculate on the future, with attention to the current and potential involvement of imaging modalities and the role of image guidance. (orig.)

2004-06-01

79

Radiation therapy in the treatment of hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

The incidence of hilar cholangiocarcinoma is very rare worldwide. Radical resection is the only prognostic factor for long survival in patients with hilar cholangiocarcinoma. Postoperative radiation therapy can improve local control and survival rates for patients with palliative resection, but it remains controversial in patients with radical resection. Biliary drainage can effectively release bile duct obstruction for the majority of patients with locally advanced disease, and may even prolong survival when combined with radiation therapy. Radiation therapy includes extrernal beam therapy alone, external beam therapy with intraluminal brachytheapy and new radiation technique, such as three dimentional conformal therapy and intensity modulated radiation therapy. The propective randomized clinical study is needed for further investigation in the role of combined modality therapy especially for hilar cholangiocarcinoma. (authors)

2007-10-01

80

Quantization of coupled 1D vector modes in integrated photonic waveguides  

International Nuclear Information System (INIS)

A quantum mechanical analysis of the guided light in integrated photonics waveguides is presented. The analysis is made starting from one-dimensional (1D) guided vector modes by taking into account the modal orthonormalization property on a cross section of an optical waveguide, the vector structure of the guided optical modes and the reversal-time symmetry in order to quantize the 1D vector modes and to derive the quantum momentum operator and the Heisenberg equations. The results provide a quantum-consistent formulation of the linear and nonlinear quantum light propagations as a function of forward and backward creation and annihilation operators in integrated photonics. As an illustration, an application to an integrated nonlinear directional coupler is given, that is, both the nonlinear momentum and the Heisenberg equations of the nonlinear coupler are derived.

2008-06-01

81

Prostate cancer immunology - an update for Urologists  

British Library Electronic Table of Contents (United Kingdom)

A better understanding of the immune processes in the pathogenesis and progression of prostate cancer (CaP) may point the way towards improved treatment modalities. The challenge is to amplify immune responses to combat tumour escape mechanisms. Infection and inflammation may have a role in prostate carcinogenesis, including the newly discovered xenotropic murine leukaemia virus (XMRV). These inflammatory states damage defence mechanisms and induce a high proliferative state favouring further mutation and impaired immune surveillance. With this knowledge we are able to explore the use of immunotherapy to rejuvenate the immune system in combating CaP. Recently Sipuleucel-T, an immunotherapeutic agent for metastatic androgen independent CaP, has resulted in improved survival and might be the...

2011-01-01

82

Paediatric radiography - the avoidance of late radiation damage to the growing hip  

Energy Technology Data Exchange (ETDEWEB)

Epiphyseal plates of growing bones are sensitive to ionizing radiation and this poses problems for the paediatric radiotherapist. In this case report we describe a child in whom electron beam therapy to the groin delivered only low dose radiation to the proximal hip epiphyses - 130 cGy fractionated over 5 weeks - but who suffered late maldevelopment. We explore the success of various radiotherapy techniques in minimizing the dose to the hip epiphyses in four other children. The appropriate positioning of the limb, the choice of treatment modality and, where possible, individual shielding blocks are considered and their effect on the dose to the hip estimated. Absorbed doses of radiation delivered to the midpoint of the proximal femoral epiphyses have been retrospectively determined. (author).

1993-04-01

83

Optimal detector deployment for the CANDU-600 pressurized heavy water reactor  

Science.gov (United States)

An optimal deployment pattern of flux mapping detectors for a Canada uranium-deuterium (CANDU)-600 pressurized heavy water reactor (PHWR) is determined by obtaining an optimal feedback relationship between flux measurements and zone controllers. The reactor core is modeled with a time-dependent two-group, two-dimensional diffusion equation, and flux perturbation are expressed by model expansions. The modal expansion coefficients are used as elements of the state vector representing the system dynamics. An optimal feedback matrix connecting the flux measurement vector to the control vector is derived by minimizing a quadratic performance index involving both the state and control vectors. We obtain the detector effectiveness in terms of the optimal feedback matrix and determine optimal detector locations for the Wolsung Unit 1 reactor in Korea. We have tested the methodology through evaluation of flux maps generated through the CANDU flux mapping system.

1992-01-01

84

NEXAFS microscopy of polymeric materials: Successes and challenges encountered when characterizing organic devices  

Energy Technology Data Exchange (ETDEWEB)

We summarize recent developments in x-ray microscopy of polymers by focusing on the characterization of organic electronic devices. The quantitative compositions of model polymer blends have been mapped at a resolution of {approx}35 nm. Since it could be inferred that these devices have structures smaller than 35 nm, quantitative compositional mapping at length scales below the present resolution limit of x-ray microscopy is required. Organic devices thus serve to both highlight the success of NEXAFS microscopy to date, but to also outline the very real need for higher spatial resolution. New approaches to create improved optics or different acquisition modalities are required if x-ray microscopy is to make sustained contributions to such an important area of research as organic devices.

2009-09-01

85

Intravaginal immunization using the recombinant HIV-1 clade-C trimeric envelope glycoprotein CN54gp140 formulated within lyophilized solid dosage forms  

British Library Electronic Table of Contents (United Kingdom)

Vaccine-mediated prevention of primary HIV-1 infection at the heterosexual mucosal portal of entry may be facilitated by highly optimised formulations or drug delivery devices for intravaginal (i.vag) immunization. Previously we described hydroxyethylcellulose (HEC)-based rheologically structured gel vehicles (RSVs) for vaginal immunization of an HIV-1 vaccine candidate, a soluble recombinant trimeric HIV-1 clade-C envelope glycoprotein designated CN54gp140. Here we investigated the efficacy of lyophilized solid dosage formulations (LSDFs) for prolonging antigen stability and as i.vag delivery modalities. LSDFs were designed and developed that upon i.vag administration they would reconstitute with the imbibing of vaginal fluid to mucoadhesive, site-retentive semi-solids. Mice were immunize...

2011-01-01

86

Inflammatory spine disease as a cause of back pain  

International Nuclear Information System (INIS)

The aim of this review is to evaluate the role of inflammatory spine disease in patients with chronic back pain. The contribution of imaging modalities for the diagnostic evaluation of back pain is discussed. A systematic literature search based on the classification of seronegative spondyloarthropathies and rheumatoid arthritis was performed. The results of this search and the experiences in a large collective of rheumatological patients are analyzed. The prevalence of rheumatoid arthritis (1-2%) is comparable to that of spondyloarthropathies (1.9%). The etiology of these entities is not fully elucidated. Magnetic resonance imaging is increasingly used for early detection and surveillance of therapy with TNF-#alpha# antagonists. Bone marrow edema, which is only detectable with MRI, represents an early sign of inflammation. Therapy with TNF-#alpha# antagonists is based on clinical and laboratory criteria, and signs of inflammation in MRI. MRI is useful for ...

2006-06-01

87

Incidence and management of secondary malignancies in patients with retinoblastoma and Ewing's sarcoma  

International Nuclear Information System (INIS)

Childhood cancer survivors at highest risk of developing a secondary malignancy are those with hereditary retinoblastoma. The majority of such secondary cancers will be sarcomas, most commonly of bone. One-third of these occur outside a typical radiation field, commonly in an extremity. Bone sarcoma is also the most commonly reported secondary cancer to develop among survivors of Ewing's sarcoma. In this group, radiation doses greater than 60 Gy as well as alkylating agent chemotherapy have been identified as contributors to the increased risk. The prognosis for patients with a secondary sarcoma has been poor, with few cures reported to date. However, an aggressive, combined modality approach, including radical resection, postoperative radiation, and adjuvant chemotherapy, may improve the survival rate.

88

Imaging of gastrinomas by nuclear medicine methods  

International Nuclear Information System (INIS)

Somatostatin receptor scintigraphy (SRS) is a valuable method for the detection of somatostatin receptor-positive lesions. Most gastrinomas (over-)express the somatostatin receptor subtype 2 which can be targeted by In-111 labeled Octreotide. Different studies show a high sensitivity of SRS for the localization and staging of gastrinomas. SRS seems to be superior to other non-invasive imaging modalities and has been proven to significantly contribute to patient management. However, the sensitivity depends on the size and exact localization of the tumors. Smaller lesions and lesions located in the duodenum show a significantly lower sensitivity. In any case, SRS belongs to the routine imaging procedure for gastrinomas for localization and staging and can also be used for evaluation of the tumor progression. (author)

89

High-dose insulin: A consecutive case series in toxin-induced cardiogenic shock  

British Library Electronic Table of Contents (United Kingdom)

Context. Cardiovascular medication overdoses can be difficult to treat. Various treatment modalities are currently recommended. Objective. To describe patient outcomes and adverse events of high-dose insulin therapy in consecutive overdose patients in cardiogenic shock after implementation of a high-dose insulin protocol (1-10 U/kg/h, while avoiding or tapering off vasopressors). Methods. This is an observational consecutive case series of patients identified from a registry. Data were collected by retrospective chart review of patients treated by our toxicology service with this protocol from February 2007 until March 2010. Results. Twelve patients were treated with high-dose insulin. The mean age was 36.5 years (SD 11.7). Seven patients had pre-existing vasopressor therapy, and all were ...

2011-01-01

90

Harnessing competence and confidence: Dimensions in education and development for advanced and consultant practice  

Energy Technology Data Exchange (ETDEWEB)

Consultant and advanced practice are relatively new concepts in radiography. There is evidence to show that as the career progression framework is being adopted the numbers of consultant and advanced practitioners in radiography are growing with the latter growing at a faster rate. The article considers the concept of advanced and consultant practice and the education requirements to support development. Preparation for an advanced practice role begins at the practitioner stage. Masters' level programmes are available to support the development of advanced practice. Education needs to be flexible as new advanced practice roles emerge. It is necessary to take practitioners beyond a defined modality to include leadership and people skills. These are essential for those aspiring to become consultants. Consultants require a high level of clinical knowledge for expert practice but also strategic vision and interpersonal intelligence to facilitate leadership and ...

2008-12-15

91

Flutter control effect and mechanism of central-slotting for long-span bridges  

British Library Electronic Table of Contents (United Kingdom)

The flutter control effect and mechanism of central-slotting, which have gradually been adopted in the design and construction of long-span bridges as an effective flutter controlling measure, were investigated with theoretical analysis and wind tunnel test. Five basic girder cross-sections representing five typical aerodynamic configurations were selected and central-slotted with two different slot widths. Then, a series of sectional model tests and theoretical analyses based on the two-dimensional three-degrees-of-freedom coupling flutter analysis method (2 dimension-3 degrees of freedom method, 2d-3DOF method) were carried out to investigate the aerody namic performance, flutter mechanism and flutter modality of the five basic sections and their corresponding central-slotted sections. T...

2007-01-01

92

Experimental compliance calibration for the mixed-mode bending (MMB) specimen  

Energy Technology Data Exchange (ETDEWEB)

A novel method to control the mixed-mode bending (MMB) specimen is presented. By maintaining a constant opening, or Mode 1, displacement rate, stable delamination growth is achieved for all mixed-mode ratios. A constant-opening displacement rate is achieved by attaching a second displacement transducer to the hinges of the specimen. The test machine is then controlled externally by the second displacement transducer. By achieving stable delamination growth and monitoring the opening displacement, an experimental compliance calibration may be derived for the Modes 1 and 2 parts. This new approach to control the test and determine the experimental compliance calibration, overcomes the potential inaccuracies of the previously used beam theory expressions to determine compliance and to separate the modal values of G.

1997-12-31

93

Designing engineering upgradability into magnetic resonance imagers: Impact on future costs  

Energy Technology Data Exchange (ETDEWEB)

MRI is a powerful diagnostic modality of expanding availability. Equipment and installation amount to nearly $2M per site. An important component of diagnostic efficacy is not just equipment costs but also replacement costs, which for x-ray CT amount to 14-20% of the purchase cost per year; and in the early years of that technology reached 30-50%. The authors show how design choices made during the RandD stages of MRI development have allowed them to improve system performance parameters such as data reconstruction, archiving and display speeds, computational capabilities, operator interfaces, imaging sequence flexibility and signal-to-noise levels. Over the last four years these improvements have been made at a retrofit cost well below the target of 6-7% of the purchase price per year.

1987-02-01

94

Chronic inflammation and mortality in haemodialysis: effect of different renal replacement therapies. Results from the RISCAVID study  

British Library Electronic Table of Contents (United Kingdom)

Background. The `RISchio CArdiovascolare nei pazienti afferenti all' Area Vasta In Dialisi (RISCAVID) study is an observational and prospective trial including the whole chronic haemodialysis (HD) population in the northwest part of Tuscany (1.235 million people). The aim of the study was to elucidate the relevance of traditional and non-traditional risk factors of mortality and morbidity in HD patients as well as the impact of different HD modalities.Methods. A total of 757 HD patients (mean age 66 +- 14 years, mean dialytic age 70 +- 76 months, diabetes 19%) were prospectively followed up for 30 months and all-cause mortality, cardiovascular (CV) mortality and non-fatal CV events (acute myocardial infarction and stroke) were registered. At the time of the enrolment, demographic, clinical...

2008-01-01

95

Changing Treatment Paradigms Hepatitis C Virus in HIV-Infected Patients  

British Library Electronic Table of Contents (United Kingdom)

The evaluation of hepatic histology and treatment of hepatitis C virus (HCV)/HIV-coinfected patients is rapidly changing. HCV has become an important cause of mortality in HIV-infected patients. Consequently, assessment of liver histology in all coinfected patients is particularly important. The evaluation of hepatic histology is shifting from reliance on the liver biopsy toward noninvasive modalities. Additionally, the importance of HCV-associated morbidity and mortality in HIV-infected patients has prompted increasing numbers of these patients to be HCV treatment candidates. Prospective trials in coinfected patients have reported lower sustained virologic responses compared to HCV-monoinfected patients. Consequently, the numbers of coinfected nonresponders to pegylated interferon/ribavir...

2007-01-01

96

Cancers | Special Issue: Advances and Research Progress in Hepatocellular Carcinoma  

Wastenet

...comAbstract: Hepatocellular carcinoma (HCC), once thought to be a rare tumor in North America, is a rapidly increasing type of cancer in recent years in the United States. Current treatment modalities to halt the disease progression are only marginally effective. The mainstay treatment ...In addition, NM was shown to down-regulate urokinase plasminogen activator (by fibrin zymography) and up-regulate tissue inhibitors of metalloproteinases (by reverse zymography) in another HCC cell line, Sk-Hep-1. MMP-2 and MMP-9 activities were further modulated by cytokines, inducers and inhibitors, including NM. In ... Our results suggest that NM is an excellent candidate for therapeutic use in the treatment HCC by inhibiting critical parameters in cancer development and progression, such as proliferation, invasion and metastasis, and by inducing apoptosis. Last update: 2 September 2011 JavaScript seems ...

97

Between Place and Interface: Designing Situated Sound for the iPhone  

British Library Electronic Table of Contents (United Kingdom)

This article explores composition skills and modalities for locative, multimedia texts by reporting experiences from a locative iPhone application that plays church music and explains that music's history in churches in Rome, Italy. Using a research by design approach, we did three rounds of observation, paper sketches, and user testing of prototypes. We found that an effective locative text must be adapted to the place in which it is intended to be experienced. The locative text must be specific, possibly referring to what the audience can see or experience at the place, and thus it is important to know how people usually behave in that particular place. Images are of little relevance in a mobile guide, except for exterior shots, which may help users to locate interesting buildings. Sound...

2011-01-01

98

Adenopathies in lung cancer: a comparison of pathology, Computed Tomography and endoscopic ultrasound findings  

International Nuclear Information System (INIS)

A prospective comparative study with pathology was performed to assess the clinical value of Computed Tomography (CT) and endoscopic ultrasound (EUS) for nodal staging in lung cancer. A total of 329 nodal stations were dissected or sampled and 755 lymph nodes were examined at histology. On a pre-station basis, CT had greater sensitivity (74%) than EUS (56%), but EUS was more specific (83% versus 93%). The accuracy rates of the two techniques were similar. In conclusion, endoscopic ultrasound should be part of a routine preoperative diagnostic approach to non-small-cell lung cancer., because of its high specificity. Results can be improved when EUS and CT are combined., which suggests that these imaging modalities should be used together in selected patients for the noninvasive staging of non-small-cell lung cancer to identify local lymphatic spread.

1999-01-01

99

A proposition of 3D inertial tolerancing to consider the statistical combination of the location and orientation deviations  

CERN Document Server

Tolerancing of assembly mechanisms is a major interest in the product life cycle. One can distinguish several models with growing complexity, from 1-dimensional (1D) to 3-dimensional (3D) (including form deviations), and two main tolerancing assumptions, the worst case and the statistical hypothesis. This paper presents an approach to 3D statistical tolerancing using a new acceptance criterion. Our approach is based on the 1D inertial acceptance criterion that is extended to 3D and form acceptance. The modal characterisation is used to describe the form deviation of a geometry as the combination of elementary deviations (location, orientation and form). The proposed 3D statistical tolerancing is applied on a simple mechanism with lever arm. It is also compared to the traditional worst-case tolerancing using a tolerance zone.

2010-01-01

100

2007 2008 ACADEMIC TRAINING PROGRAMME  

CERN Multimedia

LECTURE SERIES 14, 15, 17 January 2008 11:00 to 12:00 - Council Chamber, bldg. 503-1-001 Applications of accelerators to tumour therapy U. AMALDI, TERA Foundation & University of Milano Bicocca The first lecture is devoted to an historical review of the developments of the teletherapy techniques which make use of hadron beams and are collectively called "hadrontherapy". The main emphasis is on the use of protons and light ions, but also neutrons, pions and antiprotons are considered. The second lecture reviews the rationale behind the use of carbon ions in the treatment of radioresistant tumours and the results obtained both with proton and carbon ion beams on the 60 000 patients treated worldwide. The numbers of patients who would profit from hadrontherapy are presented together with the current landscape of running and planned hospital based centres. The main technical challenges set by this therapeutic modality are discussed in the third lecture together ...

2007-01-01

101

Sound transmission loss of composite sandwich panels  

Science.gov (United States)

Light composite sandwich panels are increasingly used in automobiles, ships and aircraft, because of the advantages they offer of high strength-to-weight ratios. However, the acoustical properties of these light and stiff structures can be less desirable than those of equivalent metal panels. These undesirable properties can lead to high interior noise levels. A number of researchers have studied the acoustical properties of honeycomb and foam sandwich panels. Not much work, however, has been carried out on foam-filled honeycomb sandwich panels. In this dissertation, governing equations for the forced vibration of asymmetric sandwich panels are developed. An analytical expression for modal densities of symmetric sandwich panels is derived from a sixth-order governing equation. A boundary element analysis model for the sound transmission loss of symmetric sandwich panels is proposed. Measurements of the modal density, total loss factor, ...

2009-01-01

102

Radiation therapy for Ewing's sarcoma: Results from Memorial Sloan-Kettering in the modern era  

International Nuclear Information System (INIS)

Purpose: To evaluate the outcomes of patients with Ewing's sarcoma family of tumors (ESFT) treated with modern radiotherapy techniques with MRI along with optimal chemotherapy. Methods and Materials: The records of all 60 patients with ESFT who received radiation to the primary site between 1990 and 2004 were reviewed. All patients received chemotherapy, including vincristine, doxorubicin, cyclophosphamide, ifosfamide, and etoposide. Radiation was used as the sole modality for local control in 31 patients and was given either before (n = 3) or after surgical resection (n = 26) in the remainder. All patients had MRI and CT scan-based treatment planning, and 43% received intensity-modulated radiation therapy. Radiation doses ranged from 30 Gy to 60 Gy (median, 51 Gy), and 35% received hyperfractionated radiotherapy. Results: Median age was 16 years (range, 2-40 years). Because of selection bias for radiotherapy, the majority of primary tumors were centrally located ...

2006-02-01

103

Quantification of cardiac function with multislice spiral CT using retrospective EKG-gating: comparison with MRI  

International Nuclear Information System (INIS)

Purpose: To quantify left ventricular function derived from retrospectively ECG-gated multislice spiral CT (MSCT) data sets in comparison to MRI. Materials and Methods: In 16 patients (14 males, 2 females, mean age 56.8 #+-# 11.5 years), retrospectively ECG-gated MSCT angiography of the coronary arteries and breath-hold steady state free precession cine MRI were performed. From MSCT data-sets, 20 axial image series were reconstructed every 5% of the RR interval. Multiplanar images were reformatted in the short axis orientation from axial images. End-systolic and end-diastolic images were selected. From these images end-systolic volume (ESV), end-diastolic volume (EDV) and stroke volume (SV) as well as the ejection fraction (EF) and myocardial mass (MM) were determined using the Simpson's method and compared with MRI. Furthermore, image quality was assessed for both imaging modalities using a four point grading scale. Results: All parameters were found to have an ...

2003-01-01

104

Pulmonary nodule detection of chest phantom with CRT images; Comparison with conventional radiography (film-screen system) and FCR hardcopy  

Energy Technology Data Exchange (ETDEWEB)

Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and displayed four images as a subsidiary diagnosis. The upper two images were displayed ...

1989-08-01

105

Pulmonary nodule detection of chest phantom with CRT images  

International Nuclear Information System (INIS)

Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and displayed four images as a subsidiary diagnosis. The upper two images were displayed ...

1989-01-01

106

Osteonecrosis of the hip joint in adults; Die Osteonekrose des Hueftgelenks im Erwachsenenalter  

Energy Technology Data Exchange (ETDEWEB)

Osteonecrosis (ON) of the hip joint remains an unsolved therapeutical problem. Diagnosis of ON of the hip has been improved by the technical progress of imaging modalities and better understanding pathomorphology. Over a long period only plain radiographs have been available. Scintigraphy and computed tomography contributed to differential diagnosis and early detection of bone necrosis. Diagnosis in an early reversible stage is of importance. Understanding of pathophysiology, early diagnosis and therapeutical approach has been significantly improved by MR imaging. Using the ARCO system all imaging modalities and their diagnostic viability are described in the five ARCO stages. At the end a diagnostic algorithm will be proposed. (orig.) [German] Die Osteonekrose des Hueftgelenks (ON) stellt noch immer ein nicht geloestes therapeutisches Problem dar. Die diagnostischen Moeglichkeiten bei der ON wurden in den letzten Jahren durch technische ...

2002-06-01

107

Le leucodistrofie: aspetti clinici e quadri con Tomografia Computerizzata e con Risonanza Magnetica  

International Nuclear Information System (INIS)

Leukodystrophies are inherited white matter diseases due to abnormalities occurring in myelin synthesis and/or maintenance. The most common types of these rare childhood conditions are represented by adrenoleukodystrophy, metachromatic leukodystrophy, Canavan's, Alexander's, Krabbe's, and Pelizaeus-Merzbacher's diseases. Most of them are lethal during childhood, with the exception of the adrenoleukodystrophy-adrenomyeloneuropathy complex, which sometimes, during its early phases, may be cured with a dietary therapy. The aims of this paper are: 1) the description of inheritance factors, pathogenesis, pathological and clinical findings of each of the most frequent childhood leukodystrophies; 2) the description of the most common patterns of these conditions on CT and MR imaging; 3) the evaluation of the diagnostic capabilities of these two imaging techniques and the comparison of their results. Finally, some of the therapies suggested for the mild forms of these conditions are discussed. ...

1991-01-01

108

Introducing DeBRa: a detailed breast model for radiological studies  

Energy Technology Data Exchange (ETDEWEB)

Currently, x-ray mammography is the method of choice in breast cancer screening programmes. As the mammography technology moves from 2D imaging modalities to 3D, conventional computational phantoms do not have sufficient detail to support the studies of these advanced imaging systems. Studies of these 3D imaging systems call for a realistic and sophisticated computational model of the breast. DeBRa (Detailed Breast model for Radiological studies) is the most advanced, detailed, 3D computational model of the breast developed recently for breast imaging studies. A DeBRa phantom can be constructed to model a compressed breast, as in film/screen, digital mammography and digital breast tomosynthesis studies, or a non-compressed breast as in positron emission mammography and breast CT studies. Both the cranial-caudal and mediolateral oblique views can be modelled. The anatomical details inside the phantom include the lactiferous duct system, the Cooper ligaments and the ...

2009-07-21

109

Influence of contrast-enhanced CT and MRI with or without SPIO particles on therapy and therapy costs for patients with focal liver disease  

International Nuclear Information System (INIS)

Purpose: Evaluation of the diagnostic efficacy and cost-benefit of contrast enhanced CT (CT) and MRI pre- and post-SPIO-particles in focal hepatic disease with consideration of therapeutic outcome. Results: In 34/52 (65.4%) of the cases the correct diagnosis was primarily stated by CT (sensitivity [se.] 85.2%, specificity [sp.] 44.0%). In additional 10/52 of the cases unenhanced MRI (se. 91.4%, sp. 75.0%) enabled correct diagnoses, and in another 6 cases the diagnosis was established only by SPIO-MRI (se. 100%, sp. 86.7%). Considering the possible therapeutic recommendation arising from each modality, CT would have induced needless therapy costs of 191,042 DM, unenhanced MRI of 171,035 DM, and SPIO-MRI of 7,311 DM. In comparison to the real therapy costs of 221,873 DM, this would have corresponded to an unnecessary increase of therapy costs of 86.1%, 77.1%, and 3.3%, respectively. In two cases (91 hemangioma, 1 regenerative nodule) all ...

2000-03-01

110

Influence of anchor behaviour on the earthquake response of liquid storage tanks  

International Nuclear Information System (INIS)

The dynamic response of thin liquid storage tanks to earthquakes is a very complicated phenomenon, because it can be highly non linear. Among others, one can meet material and geometric non linearities of the tank shell leading eventually to static or dynamic buckling non linear behavior of anchor bolts, contact non-linearities due to the uplift of the tank base and to the unilateral character of the fluid pressure on the shell and high amplitude fluid oscillations. Moreover, linear or non linear soil structure interaction affects considerably the response of the fluid structure system under consideration. In this paper we focus attention on problems related only to the base uplift and anchors plastification. We study a tank similar to the Hualien project tank, but we neglect the soil structure interaction. The studied tank is representative of medium height to radius ratio ratio tanks with relatively thick bottom plate. The contact is simulated via a simple discrete penalty method in ...

111

Guidebook to financing CDM projects  

Energy Technology Data Exchange (ETDEWEB)

One of the challenges facing Clean Development Mechanism (CDM) projects today is their limited ability to secure financing for the underlying greenhouse gas emission reduction activities, particularly in the least developed countries. Among the key reasons for this is the fact that most financial intermediaries in the CDM host countries have limited or no knowledge of the CDM Modalities and Procedures. Moreover, approaches, tools and skills for CDM project appraisal are lacking or are asymmetrical to the skills in comparable institutions in developed countries. Consequently, developing country financial institutions are unable to properly evaluate the risks and rewards associated with investing or lending to developers undertaking CDM projects, and therefore have, by-and-large, refrained from financing these projects. In addition, some potential project proponents lack experience in structuring arrangements for financing a project. This Guidebook - commissioned by ...

2007-07-01

112

Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOVA test. The mean ROC areas of conventional radiography, indirect digital radiography, direct ...

2003-03-15

113

Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries  

International Nuclear Information System (INIS)

The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOVA test. The mean ROC areas of conventional radiography, indirect digital radiography, direct ...

2003-03-01

114

Combined chemotherapy and radiotherapy: from biology to bed-side  

International Nuclear Information System (INIS)

Combination of radiotherapy and chemotherapy (CRC) is actually one important way of research in oncology. Theoretical advantages are: (1) Spatial cooperation; (2) Additivity, which is only obtained if the toxicity of each modality are different; (3) Supra-additivity, which needs a rigorous in vitro definition; the only way to prove it is to make an isobologram analysis. This model has however, some limitations: qualitative variable could not be used, results could be different, depending on the cell line and isoeffect chosen...In fact, a supra-additivity was only demonstrated for cis platinum and etoposide. Interactions mechanisms were: (1) at the molecular level, creation of new lesions or inhibition of radiation lesions repair; (2) At the cellular level, either cytokinetic cooperation with S-phase dependent drugs, or synchronization for the drugs which blocked the cells in M-phase; (3) At the tissular level, reoxygenation, cycle redistribution. In clinical ...

115

ANALYSIS OF ACCELERATOR BASED NEUTRON SPECTRA FOR BNCT USING PROTON RECOIL SPECTROSCOPY  

Energy Technology Data Exchange (ETDEWEB)

Boron Neutron Capture Therapy (BNCT) is a promising binary treatment modality for high-grade primary brain tumors (glioblastoma multiforme, GM) and other cancers. BNCT employs a boron-10 containing compound that preferentially accumulates in the cancer cells in the brain. Upon neutron capture by {sup 10}B energetic alpha particles and triton released at the absorption site kill the cancer cell. In order to gain penetration depth in the brain Fairchild proposed, for this purpose, the use of energetic epithermal neutrons at about 10 keV. Phase I/II clinical trials of BNCT for GM are underway at the Brookhaven Medical Research Reactor (BMRR) and at the MIT Reactor, using these nuclear reactors as the source for epithermal neutrons. In light of the limitations of new reactor installations, e.g. cost, safety and licensing, and limited capability for modulating the reactor based neutron beam energy spectra alternative neutron sources are being contemplated for wider ...

1998-11-06

116

Virtual colonoscopy (CT colonography) in the identification of colorectal cancer. A prospective study in symptomatic patients; Impiego dell'endoscopia virtuale con Tomografia Computerizzata nell'identificazione delle neoplasie colorettali. Studio prospettivo in pazienti sintomatici  

Energy Technology Data Exchange (ETDEWEB)

Aim of this study was to evaluate the sensitivity of virtual colonoscopy (CT colonography) in the identification of colorectal cancer and to define the limitations and the advantages of this imaging modality, as well as indications to the examination. It was examined prospectively 62 symptomatic patients aged 36 to 82 years (28 women and 34 men). All patients underwent both conventional and virtual colonoscopy on the same day; the conventional examination allowed exploration of the entire colon. Conventional colonoscopy identified 89 lesions 3-50 mm in diameter, namely 84 benign and 5 malignant lesions. No lesions were identified in 12 patients. CT colonography identified 52 of the 89 lesions, with 57.1% diagnostic accuracy. They were 11 false positives (82.5% positive predictive value and 52.2% specificity) and 37 false negatives (24.5% negative predictive value and 58.4% sensitivity). Sensitivity was significantly higher (85.7%) for polyps {>=} 1 cm. ...

2000-06-01

117

Vibration test report on the instrumented capsule for fuel irradiation test  

Energy Technology Data Exchange (ETDEWEB)

The fluid-induced vibration level of instrumented capsule, which was manufactured for fuel irradiation test at the reactor core of HANARO, was investigated. For this purpose, the instrumented capsule was loaded at the OR site of the HANARO design verification test facility that could simulate identical flow condition as the HANARO core. Then, vibration signals of the instrumented capsule subjected to various flow conditions were measured by using vibration sensors. In time domain analysis, maximum amplitudes and RMS values of the measured acceleration and displacement signals were obtained. By using frequency domain analysis, frequency components of the fluid-induced vibration were analyzed. In addition, natural frequencies of the instrumented capsule were obtained by performing modal test. The frequency analysis results showed that the natural frequency components near 7.5Hz and 17.5Hz were dominant in the fluid-induced vibration signal. The maximum amplitude of ...

2003-01-01

118

Untersuchung von Bildqualitat und Genauigkeit der Dosisberechnung bei cone-beam-CT-Aufnahmen mit reduziertem Projektionsdatensatz (half scan, half fan) im Hinblick auf die Verwendbarkeit fur die adaptive Bestrahlungsplanung  

British Library Electronic Table of Contents (United Kingdom)

Subject of this study is the question of whether cone beam CT (CBCT) images with reduced projection data are suitable for use in adaptive radiation therapy (ART) treatment planning. For this purpose image quality and dose calculation accuracy depending on imaging modality were analysed. In this context, two CBCT-methods will be indicated having reduced projection data sets: Scans acquired with 200^o rotation angle in order to accelerate the CBCT process (half scan), or scans with an asymmetric cone beam and detector offset, used to enlarge the field-of-view (half fan). Methods: For three different CBCT-modes (On-Board-Imaging, Varian Medical Systems), two of them based on reduced projection data, and a conventional multidetector CT system, the main image quality parameters were studied. Tr...

2011-01-01

119

Treatment of proliferative haemangiomas with the 585 nm pulsed dye laser.  

Science.gov (United States)

Haemangiomas usually develop within the first few weeks of life, most regressing spontaneously before the age of 7 years. Some may ulcerate or compromise a vital function, in which case systemic corticosteroids, surgery or radiotherapy may be helpful. All of these treatment modalities are associated with significant morbidity. Treatment with the 585 nm flashlamp pulsed dye laser is safe and effective in the management of superficial vascular malformations. We report seven patients, under 12 months of age, who presented with proliferative haemangiomas, causing functional impairment. Ulcerated lesions were present in four patients. The patients were treated with the 585 nm pulsed dye laser (fluences 7.0-9.25 J/cm2), at intervals of 4-8 weeks. All of the lesions showed a significant reduction in size, together with improvement in the colour and integrity of the overlying skin. Treatment with the 585 nm pulsed dye laser should be considered in the management of infants ...

1996-04-01

120

Treatment of cancer of the pancreas by intraoperative electron beam therapy: physical and biological aspects  

Energy Technology Data Exchange (ETDEWEB)

Radiation therapy has had a significant and an expanded role in the management of cancer of the pancreas during the last decade. In particular, for locally advanced disease, radiation therapy has improved the median survival of patients to 1 year. Intraoperative electron beam therapy has been applied to unresectable and resectable pancreatic cancer in an attempt to enhance local control of disease and to improve patient survival. This paper presents a survey of the role of radiation therapy in treatment of cancer of the pancreas, provides information on the radiobiological aspects of this treatment modality and details the physical and dosimetric characteristics of intraoperative radiation therapy with electrons. Presented are the design specifics of an applicator system, central axis beam data, applicator parameters, dose distribution data, shielding, treatment planning and means of verification. Emphasis is placed on the collaboration and cooperation necessary ...

1989-01-01

121

Treatment of cancer of the pancreas by intraoperative electron beam therapy: physical and biological aspects  

International Nuclear Information System (INIS)

Radiation therapy has had a significant and an expanded role in the management of cancer of the pancreas during the last decade. In particular, for locally advanced disease, radiation therapy has improved the median survival of patients to 1 year. Intraoperative electron beam therapy has been applied to unresectable and resectable pancreatic cancer in an attempt to enhance local control of disease and to improve patient survival. This paper presents a survey of the role of radiation therapy in treatment of cancer of the pancreas, provides information on the radiobiological aspects of this treatment modality and details the physical and dosimetric characteristics of intraoperative radiation therapy with electrons. Presented are the design specifics of an applicator system, central axis beam data, applicator parameters, dose distribution data, shielding, treatment planning and means of verification. Emphasis is placed on the collaboration and cooperation necessary ...

122

Thermomechanical vibration analysis of a functionally graded shell with flowing fluid  

Energy Technology Data Exchange (ETDEWEB)

This paper reports the results of an investigation into the vibration of functionally graded cylindrical shells with flowing fluid, embedded in an elastic medium, under mechanical and thermal loads. By considering rotary inertia, the first-order shear deformation theory (FSDT) and the fluid velocity potential, the dynamic equation of functionally graded cylindrical shells with flowing fluid is derived. Here, heat conduction equation along the thickness of the shell is applied to determine the temperature distribution and material properties are assumed to be graded distribution along the thickness direction according to a power-law in terms of the volume fractions of the constituents. The equations of eigenvalue problem are obtained by using a modal expansion method. In numerical examples, effects of material composition, thermal loading, static axial loading, flow velocity, medium stiffness and shell geometry parameters on the free vibration characteristics are ...

2008-11-15

123

The use of "1"3"1I-radioiodine in diagnostic and treatment: estimated risk in Guanabara  

International Nuclear Information System (INIS)

The "1"3"1-radioiodine use in Guanabara area, during 1972-1973, is analysed. References are made to the radiation levels delivered to thyroid, bone marrow and gonads in a population of 27000 people examined by tracer techniques, 190 submitted to hyperthyroidism treatment and 50 treated for thyroid cancer. The pertinent literature gives some data concerning radiation induced cancer (leukaemia and thyroid cancer). By this, it was possible to estimate the probability of tumour occurrence in that population, assuming a linear relationship between dose and effect. The conclusions are the followings: 1 - there are many duties in this field at the present; 2 - the leukaemia incidence related to the 131-radioiodine use is negligible, either in diagnostic or therapeutic modalities; 3 - the possibility of thyroid tumors induced by radiation is real, specially in hyperthyroidism treatment; 4 - the use of tracer techniques that cause lower irradiation to the pacient is ...

124

TTF HOM Data Analysis with Curve Fitting Method  

Energy Technology Data Exchange (ETDEWEB)

To investigate the possibility of using HOM signals induced in SC cavities as beam and cavity diagnostics, narrow band (20 MHz) data was recorded around the strong TE111-6(6{pi}/9-like) dipole modes (1.7 GHz) in the 40 L-band (1.3 GHz) cavities at the DESY TTF facility. The analyses of these data have so far focused on using a Singular Value Decomposition (SVD) technique to correlate the signals with each other and data from conventional BPMs to show the dipole signals provide an alternate means of measuring the beam trajectory. However, these analyses do not extract the modal information (i.e., frequencies and Q's of the nearly degenerate horizontal and vertical modes). In this paper, we described a method to fit the signal frequency spectrum to obtain this information, and then use the resulting mode amplitudes and phases together with conventional BPM data to determine the mode polarizations and relative centers and tilts. Compared with the SVD ...

2009-07-14

125

Steady-state Ab Initio Laser Theory: Generalizations and Analytic Results  

CERN Document Server

We improve the steady-state ab initio laser theory (SALT) of Tureci et al. by expressing its fundamental self-consistent equation in a basis set of threshold constant flux states that contains the exact threshold lasing mode. For cavities with non-uniform index and/or non-uniform gain, the new basis set allows the steady-state lasing properties to be computed with much greater efficiency. This formulation of the SALT can be solved in the single-pole approximation, which gives the intensities and thresholds, including the effects of nonlinear hole-burning interactions to all orders, with negligible computational effort. The approximation yields a number of analytic predictions, including a "gain-clamping" transition at which strong modal interactions suppress all higher modes. We show that the single-pole approximation agrees well with exact SALT calculations, particularly for high-Q cavities. Within this range of validity, it provides an extraordinarily efficient ...

2010-01-01

126

Solid-pseudopapillary tumor of the pancreas in a 13-year-old girl - case report  

International Nuclear Information System (INIS)

The solid-pseudopapillary tumor (SPT) of the pancreas is a rare type of exocrine pancreatic neoplasm. SPT predominantly affects young women and female children, and is usually discovered incidentally. This tumor is generally benign with a low incidence of malignancy. A 13-year-old girl was admitted to the hospital with a few weeks' history of mild abdominal pain and jaundice. On physical examination, there was no palpable mass. The laboratory tests showed increased SR, CRP, high bilirubin, amylase and lipase serum levels. Ultrasound imaging revealed a solid lesion in the region of the pancreatic head. On MRI, precise tumor localization in the head of the pancreas with pancreatic duct dilatation and compression of the common bile duct were visualized. Pancreaticoduodenectomy and cholecystectomy was performed with good clinical outcome. Microscopic and immunohistochemical studies indicated that tumor cells were typical of SPT without any signs of malignancy. After surgical treatment, the ...

127

Scale-model characterization of flow-induced vibrational response of FFTF reactor internals  

Energy Technology Data Exchange (ETDEWEB)

Fast Test Reactor core internal and peripheral components were assessed for flow-induced vibrational characteristics under scaled and simulated prototype flow conditions in the Hydraulic Core Mockup as an integral part of the Fast Test Reactor Vibration Program. The Hydraulic Core Mockup was an 0.285 geometric scale model of the Fast Test Reactor internals designed to simulate prototype vibrational and hydraulic characteristics. Using water to simulate sodium coolant, vibrational characteristics were measured and determined for selected model components over the scaled flow range of 36 to 110%. Additionally, in-situ shaker tests were conducted on selected Hydraulic Core Mockup outlet plenum components to establish modal characteristics. Most components exhibited resonant response at all test flow rates; however, the measured dynamic response was neither abnormal nor anomalously flow-rate dependent, and the predicted prototype components' response were ...

1980-10-01

128

Radiological concepts in radiotherapy  

International Nuclear Information System (INIS)

The atomic explosions in Hiroshima and Nagasaki made the name radiation itself become a nightmare. Notwithstanding this, radiation continued to serve the mankind specially in diagnosis of several human diseases and in the treatment of intractable malignancies. With their latest research tools biologists have now shown a significant shift in the earlier paradigm; even the concept that radiation initiates cancer appears to be no longer tenable. On the contrary, selective radiation doses inhibit growth of cancer cells and radiation in combination with many chemotherapeutic drugs, radiosensitizing chemicals and/or hyperthermia, is emerging as a new modality for cancer treatment which offers high therapeutic advantages. In addition, the deleterious effects of radiation can now be strategically counter poised by the use of many drugs and chemicals. This has been possible by the newer insights gained in the mechanism of biological effects of radiation. The fate of ...

129

Radiation, adriamycin, and skin reactions: effects of radiation and drug fractionation, hyperthermia, and tetracycline. [X rays  

Energy Technology Data Exchange (ETDEWEB)

The effect of adriamycin in combination with radiation on the skin reactions of mouse feet has been examined under a variety of experimental conditions including: (a) hyperthermic treatment of the foot immediately following adriamycin administration, with the former given either just before or just after x irradiation, and (b) fractionated treatments of drug and radiation in a variety of sequences over an 18-day period. In the case of the most severe hyperthermic treatment, no increased radiation reactions were observed in the presence of adriamycin. However, in the case of the less severe hyperthermic treatment a small but significant increase in skin reactions was observed. In the study of fractionated drug and radiation treatments, an enhancement of reaction in those animals receiving combined modality treatment over those receiving radiation alone was seen in those groups where the initiation of drug treatment succeeded the initiation of radiation treatment by ...

1981-06-01

130

Prognosis of non-small cell lung cancer with brain metastases and the clinical role of cranial irradiation  

Energy Technology Data Exchange (ETDEWEB)

Prognosis of 95 consecutive patients with non-small cell lung cancer with brain metastases were evaluated. Three factors, therapy for brain metastases, general performance status (PS) and distant metastases to other organs had significant impact on survival. Among these 3 factors, PS was independent from the other 2 factors. Significant correlation was present, however, between therapy and other organ metastases, and few patients with brain and other distant metastases received aggressive treatment for brain metastases. Cranial irradiation had significant impact on survival even in those patients with brain and other distant metastases. Cranial irradiation also reduced death from brain metastases in responders. Our results indicate that there are several subgroups with different prognosis in patients with non-small cell lung cancer with brain metastases, therefore the most beneficial treatment modality should be selected for each group of patients. (author).

1990-10-01

131

Modern imaging methods for diagnostic evaluation of tumors of the oropharynx and the oral cavity  

International Nuclear Information System (INIS)

Differentiating a benign from a malignant lesion by information such as density data, or signal intensities or echo gradients, is not possible with CT, nor MRI, nor ultrasonography. Only some lesions show characteristic signs. Inflammations cannot be difscriminated from malignant tumors. CTs of small tumors in particular are so poor in contrast that it is much more difficult to detect tumors or discriminate them from other lesions, as compared to MR images or ultrasonographs. CT does not detect surface tumors, but is more sensitive than MRI or US in detecting discrete cortical bone lesions. The same applies to small calcified tumors. MRI however is most sensitive in detecting tumor volumes in the yellow marrow, and is the best modality for evaluation of extraossal extension of tumors. CT yields better results than MRI if applied for simultaneous screening of lymph node metastases in the lower neck. MRI frequently is spoilt by movement artefacts. High-resolution, ...

132

Lipiodol-CT findings of hepatocellular carcinoma: Correlation with lipiodol accumulation pattern and serum AFP  

Energy Technology Data Exchange (ETDEWEB)

Early diagnosis of hepatocellular carcinoma (hepatoma) along with surgical resection is the most appropriate therapeutic modality. For this purpose, there have been many reports concerning the diagnostic value of Lipiodol-CT scan. The authors selected 45 patients with hepatoma during the period of Feb.1986 to Jan. 1988 who received a conventional CT scan, hepatic angiography and a Lipiodol-CT scan. The results were as follows: 1. There was no statistical significant between serum AFP level and mass size, morphology and amount of necrosis. 2. Tumor necrosis was observed in a single massive and multinodular type when the tumor size exceeded 5 cm. 3. Pattern II on Lipiodol-CT, homogenous accumulation of Lipiodol except for the area of inner necrosis, was most frequently demonstrated, which means that a tumor mass with hypervascularity and increased blood flow will attract Lipiodol better. 4. Lipiodol-CT was superior to conventional CT in detecting small, daughter ...

1989-12-15

133

Intrahepatic cholangiocarcinoma : gross appearance and corresponding pathologic and radiologic features  

International Nuclear Information System (INIS)

To assess the clinical and pathologic features of each type of intrahepatic cholangiocarcinoma, which is divided into three types according to gross appearance, and to determine the efficacy of CT in detecting this tumor. The pathologic and CT features of 53 surgically proven cases of intrahepatic cholangio-carcinoma were reviewed. On the basis of their gross appearance, the tumors were divided into three types, as follows : mass forming (n=33), periductal infiltrating (n=6), and intraductal growth type (n=14). CT scans were analyzed for sensitivity of detection and correlation between a tumors appearance and its histopathology. The most common histopathologic feature of mass forming and periductal infiltrating type was tubular adenocarcinoma, while in the intraductal growth type, papillary adenocarcinoma (100%) was common. With regard to pattern of tumor spread, intrahepatic and lymph node metastasis were more common in the mass forming and periductal infiltrating type than in the ...

1999-05-01

134

Imaging Ewing's sarcoma  

International Nuclear Information System (INIS)

Ewing's sarcoma is a highly malignant neoplasm of the bone whose origin is still uncertain. A strong relationship exists between Ewing's sarcoma and tumors of neural origin (Ewing family of tumors). Ewing's sarcoma must be distinguished from other round-cell tumors like lymphoma and neuroblastoma and also must be differentiated from osteogenic sarcomas. On plain radiographs, Ewing's sarcoma appears as a lytic or mixed lytic-sclerotic, rarely as predominantly sclerotic lesion with margins Lodwick grade III. It is located primarily in the diaphyseal and metadiaphyseal regions of the long bones of the lower extremities. A large soft tissue tumor is usually present. Magnetic resonance imaging is the imaging modality of choice to evaluate the extent of the primary lesion, to monitor the response to neoadjuvant chemotherapy and to follow up non-resected Ewing's sarcomas. Bone scintigraphy is necessary to detect skeletal metastasis, and "2"0"1thallium scanning has been ...

1998-06-01

135

Health-related quality of life following percutaneous coronary intervention: the impact of age on outcome at 1 year.  

Science.gov (United States)

This study was performed to assess the possibility that patient age may independently affect improvements in health-related quality of life following percutaneous coronary intervention. One hundred five patients undergoing elective percutaneous coronary intervention at a single tertiary referral center between January 10, 2001 and January 6, 2002 were enrolled and prospectively evaluated. Health-related quality of life was assessed before and 1 year following percutaneous coronary intervention using Short Form-12 and the Seattle Angina Questionnaire. For the purpose of analysis, patients were divided according to age (younger than 60, 60-70, and older than 70 years). One hundred patients (95%) completed both questionnaires. Baseline characteristics among the age groups were similar in terms of gender, cardiac risk factors, and procedural details. All health-related quality-of-life indices demonstrated improvements with at least four variables in each group achieving a clinically ...

136

Ganglioneuromas in childhood: MRI and CT characteristics  

International Nuclear Information System (INIS)

Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI T_1-weighted scans the tumors were homogeneous and hypointense, after ...

2000-05-01

137

Engineering design of cryocondensation pumps for the DIII-D Radiative Divertor Program  

Energy Technology Data Exchange (ETDEWEB)

A new double-null, slotted divertor configuration will be installed for the DIII-D Radiative Divertor Program at General Atomics in late 1996. Four cryocondensation pumps, three new and one existing, will be part of this new divertor. The purpose of the pumps is to provide plasma density control and to limit the impurities entering the plasma core by providing pumping at each divertor strike point. The three new pumps are based on the design of the existing pump, installed in 1992 as part of the Advanced Divertor Program. The pump continues to operate successfully. The new pumps require geometry modifications to the original design. Therefore, extensive modal and dynamic analyses were performed to determine the behavior of these pumps and their helium and nitrogen feed lines during disruption events. Thermal and fluid analyses were also performed to characterize the helium two-phase flow regime in the pumps and their feedlines. A flow testing program was completed ...

1995-12-31

138

Engineering design of cryocondensation pumps for the DIII-D Radiative Divertor Program  

Energy Technology Data Exchange (ETDEWEB)

A new double-null, slotted divertor configuration will be installed for the DIII-D Radiative Divertor Program at General Atomics in late 1996. Four cryocondensation pumps, three new and one existing, will be part of this new divertor. The purpose of the pumps is to provide plasma density control and to limit the impurities entering the plasma core by providing pumping at each divertor strike point. The three new pumps are based on the design of the existing pump, installed in 1992 as part of the Advanced Divertor Program. The new pumps require geometry modifications to the original design. Therefore, extensive modal and dynamic analyses were performed to determine the behavior of these pumps and their helium and nitrogen feed lines during disruption events. Thermal and fluid analyses were also performed to characterize the helium two-phase flow regime in the pumps and their feedlines. A flow testing program was completed to test the change in geometry of the pump ...

1995-10-01

139

Engineering design of cryocondensation pumps for the DIII-D Radiative Divertor Program  

International Nuclear Information System (INIS)

A new double-null, slotted divertor configuration will be installed for the DIII-D Radiative Divertor Program at General Atomics in late 1996. Four cryocondensation pumps, three new and one existing, will be part of this new divertor. The purpose of the pumps is to provide plasma density control and to limit the impurities entering the plasma core by providing pumping at each divertor strike point. The three new pumps are based on the design of the existing pump, installed in 1992 as part of the Advanced Divertor Program. The pump continues to operate successfully. The new pumps require geometry modifications to the original design. Therefore, extensive modal and dynamic analyses were performed to determine the behavior of these pumps and their helium and nitrogen feed lines during disruption events. Thermal and fluid analyses were also performed to characterize the helium two-phase flow regime in the pumps and their feedlines. A flow testing program was completed ...

1995-10-01

140

Emission characterization of an alcohol/diesel-pilot fueled compression-ignition engine and its heavy-duty diesel counterpart. Final report, August 1980-August 1981  

Energy Technology Data Exchange (ETDEWEB)

This report describes results from emissions testing of a prototype diesel engine, developed by Volvo Truck Corporation of Sweden, which uses pilot injection of diesel fuel for compression ignition of alcohol fuel injection for main combustion. In addition to this dual-fuel engine, emission testing was also conducted on a heavy-duty diesel engine of similar design. Both engines were tested over the 1979 13-mode FTP, or shorter versions of this modal test, and over the 1984 Transient FTP as well as an experimental bus cycle. The dual-fuel engine was characterized with methanol, ethanol and ethanol with 30 percent water (wt %). An oxidation catalyst was also used with methanol and ethanol. Emission characterization included regulated emissions (HC, CO, and NOX) along with total particulate, unburned alcohols, individual hydrocarbons, aldehydes, phenols, and odor. The particulate matter was characterized in terms of particle size distribution, sulfate content, C, H, ...

1981-08-01

141

Diagnostic features of intrahepatic cholangiocarcinoma according to the gross type classification  

International Nuclear Information System (INIS)

Forty resected cases of intrahepatic cholangiocarcinoma were classified into four types according to the gross appearance; type I: mass forming type (n=8), type II: mass forming with periductal infiltrating type (n=20), type III: periductal infiltrating type (n=9) and type IV: intraductal growth type (n=3). Diagnostic features of these four types were studied. Peripheral enhancement was a common angiographic feature and tumor stains were recognized in 88%, 20%, 0%, 33%, respectively. Angiography and dynamic computed tomography (D-CT) were useful in differential diagnosis with hepatocellular carcinoma. Accuracy rate in diagnosis of portal vein involvement by angiography and D-CT was 82% and 91%, respectively. MRI was more useful in tumor detection than D-CT in cases with attenuation difference, in 55% of type II and in 75% of type III. Increase of arterial involvement, biliary tract involvement and portal vein involvement, incidence of lymph nodes metastases became higher. Spread ...

1998-08-01

142

Design of composite plate specimens for measurement of through-the-thickness shear properties in vibration experiments  

Energy Technology Data Exchange (ETDEWEB)

This research involves the development of an analysis which yielded recommendations regarding the plate thickness at which the effects of transverse shear become significant enough to be taken into consideration during vibration testing of composite plates. The specimens designed using this analysis are to be used for the {open_quotes}inverse{close_quotes} problem of determining through-the-thickness elastic constants as well as in-plane elastic constants from modal vibration response data. The effects of transverse shear were studied over the range of practical plate aspect ratios (length to thickness ratios) and mode numbers. Behavior of composite plates ranging from isotropic to highly orthotropic was studied in order to investigate the effects of transverse shear. Orthotropic plates having in-plane dimensions of 254 x 254 mm and thicknesses varying from 10 mm to 80 mm, with free-free edge boundary conditions, were considered. A methodology was developed to use ...

1997-12-31

143

Cooperation of Russian and EU technical support organizations  

International Nuclear Information System (INIS)

Since 1992, the fruitful collaboration of the Russian and Western-European technical support organizations (TSOs) is being continued due to the support of the European Commission. There are two main areas of activities. The first one is more of methodological assistance and enhancing RF TSOs capabilities to support Rostekhnadzor decision making process. Experience and knowledge acquired in this area projects increase RF TSOs capabilities regarding a wide spectrum of safety related issues assessment, in particular safety analyses, reactor vessel embrittlement, application of 'leak before break' concept, severe accident and accident management, fire risk evaluation, etc. The second area is focused on licensing related assessments of EC financed on site assistance projects (modernisations). This area projects promote implementation in Russia a licensing process based on a technical dialogue between operator and regulator as well contributes to transfer of Western practice in assessment of ...

2007-08-01

144

Computed radiography for major airway in pediatrics  

International Nuclear Information System (INIS)

This paper shows the efficacy of computed radiography for major airway in pediatrics. For this purpose, we examined 40 children (range 2 weeks to 14 years; mean 2.3 years) using Fuji Computed Radiography (FCR) and radiation dose using pediatric phantom under FCR and conventional film and screen system. In comparison study with FCR and conventional film and screen system, FCR images are superior to conventional system in all cases. Scorings were done for the quality of the image of the pharynx, the trachea, and both main bronchi. In phantom study to check radiation dose, radiation dose could be reduced 1/6 of the value using high speed film and screen and 1/15 of the value using conventional speed film and screen. FCR also showed clear airway images in all cases but technical failure to evaluate the clinical lesion. These results suggest that FCR is the adequate imaging modality to evaluate the major airway in children. (author).

1986-01-01

145

Cf-source-driven neutron-noise measurements of subcriticality for a 4. 95 wt% /sup 235/U-enriched uranyl fluoride solution cylinder  

Energy Technology Data Exchange (ETDEWEB)

A method for determining the reactivity of subcritical systems of fissile material, using neutron-noise power spectral density measurements in conjunction with a /sup 252/Cf source, has been tested in experiments with an aqueous solution containing uranium fluoride (4.95 wt% /sup 235/U). The kappasub(eff)-values obtained from the ratio of spectral densities G*/sub 12/G/sub 13//G/sub 11/G/sub 23/ agreed with those from break-frequency noise analysis and with bias-corrected transport theory calculations within the statistical uncertainty of the measurements. Corrections for the effects of spatial modes and source-detector locations appear to be well-understood, since measurements for a variety of source-detector positions resulted in essentially the same kappasub(eff)-values. Modal correction factors were such that ignoring them would result in higher values of kappasub(eff) than actually occur. The measurements have demonstrated the applicability of the /sup ...

1986-01-01

146

Calculation of the transmission capacity of long-distance EHV single-core submarine cable systems  

Energy Technology Data Exchange (ETDEWEB)

A general calculation method for the analysis of transmission capability of a long-distance single-core ac submarine cable system is presented. The method is based on modal transformation of voltages and currents in multiconductor cable systems. Using this method, numerical calculations on 500 kV submarine cable systems have been performed with particular reference to the effect of the distance between bonds connecting metallic sheath, outer conductor and armor on the transmission capacity of the system. It was clarified that the transmission capacity of the system increased with decreasing bond intervals. Examination of the current distributions between various conductors along the length showed that this increase of transmission capacity was mainly due to the dispersion of the charging current into the metallic sheath, outer conductor and armoring at the bonding points. Analytical results for the transmission capacities of long-distance 500 kV single-core ...

1981-11-01

147

Behaviour of nonlinear supports on a PWR coolant system during a postulated LOCA. Pt. 1; Effect of modelling methods  

Energy Technology Data Exchange (ETDEWEB)

A 4-loop Pressurised Water Reactor (PWR) primary coolant system has been analysed for the postulated Loss of Coolant Accident (LOCA) event in order to derive peak dynamic loads for qualifying the design of equipment supports and pipe whip restraints. Pipe whip restraints as well as pipe and equipment supports are nonlinear by nature because of the presence of gaps and the different directional stiffnesses arising from snubber, steelwork and geometric and material interaction at the concrete to steel embedment. The different structural idealisations for the supports and restraints have an influence on the dynamic response of the structure. In the first of the two part paper a range of idealisation models for the Steam Generator and Reactor Coolant Pump vertical columns ranging from elastic stiffnesses to bilinear stiffnesses with or without preload were examined. Due to both structural and loading complexity, the behaviour of these supports were analysed by the Nonlinear ...

1993-07-01

148

Automatic Annotation of XHTML Pages with Audio Components  

CERN Document Server

In the past ten years, significant research effort was invested in audio browsers, programs able to decode the structure of Web pages and put them into an audio format. Few advanced browsers use machine learning algorithms to classify objects on the Web page and learn browsing behaviors, have multimodal input and outputs and are able to synchronize between the graphical and audio modalities to interact with the Web page. The disadvantages of these audio browsers include the necessity of a high computation power since the user's machine has to decode the structure of the Web page, and, therefore, making impossible the installation of such programs on mobile devices. In this paper, we propose a simpler and more efficient solution for the creation of a multimodal application. We developed a middleware that automatically annotates Web pages with VoiceXML generated from the content of the Web page. Using our system, the user can interact with the Web page, by using ...

2007-01-01

149

Analysis on Dose Distribution in Heterogeneous Condition for Narrow 6 MV X-ray Beams  

International Nuclear Information System (INIS)

Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous condition since the GAFCHROMICat..EBT film is composed of tissueequivalent ...

2010-10-01

150

A clinical perspective on common forms of acquired heterotopic ossification  

Energy Technology Data Exchange (ETDEWEB)

The clinical courses of heterotopic ossification (HO) as a consequence of trauma and central nervous system insults have many similarities as well as dissimilarities. Detection is commonly noted at two months. The incidence of clinically significant HO is 10%-20%. Approximately 10% of the HO is massive and causes severe restriction in joint motion or ankylosis. The most common sign and symptom are decreased range of motion and pain. The locations are the proximal limbs and joints. Sites of HO about a joint may vary according to the etiology of the HO. Roentgenographic evolution of HO occurs during a six-month period in the majority of patients. Treatment modalities include diphosphonates, indomethacin, radiation, range of motion exercises, and surgical excision. Surgical timing differs according to etiology: traumatic HO may be resected at six months; spinal cord injury HO is excised at one year; and traumatic brain injury HO is removed at 1.5 years. A small number ...

1991-02-01

151

A clinical perspective on common forms of acquired heterotopic ossification  

International Nuclear Information System (INIS)

The clinical courses of heterotopic ossification (HO) as a consequence of trauma and central nervous system insults have many similarities as well as dissimilarities. Detection is commonly noted at two months. The incidence of clinically significant HO is 10%-20%. Approximately 10% of the HO is massive and causes severe restriction in joint motion or ankylosis. The most common sign and symptom are decreased range of motion and pain. The locations are the proximal limbs and joints. Sites of HO about a joint may vary according to the etiology of the HO. Roentgenographic evolution of HO occurs during a six-month period in the majority of patients. Treatment modalities include diphosphonates, indomethacin, radiation, range of motion exercises, and surgical excision. Surgical timing differs according to etiology: traumatic HO may be resected at six months; spinal cord injury HO is excised at one year; and traumatic brain injury HO is removed at 1.5 years. A small number ...

152

Comparison of high resolution whole-body MRI using parallel imaging and PET-CT. First experiences with a 32-channel MRI system  

International Nuclear Information System (INIS)

To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI scanner (Magnetom Avanto, Siemens Medical Solutions) with a total field of view of ...

153

Assessment of the value of various tomography modalities for diagnostic evaluation of the female genital system; Stellenwert der Schnittbildverfahren bei der Abklaerung von Erkrankungen des weiblichen Genitaltrakts  

Energy Technology Data Exchange (ETDEWEB)

The comprehensive survey explains the indications and the specific value of the modern tomographic modalities with respect to the various diagnostic issues. Numerous reproductions of CT, MRI, US scans illustrate the aspects discussed. (orig./CB) [German] Bildgebende Verfahren kommen bei der Abklaerung von Erkrankungen des weiblichen Urogenitaltrakts ergaenzend zu der klinischen Untersuchung zur Anwendung. Kongenitale Uterusanomalien werden primaer mit der HSG oder der Laparoskopie diagnostiziert. Zusaetzlich koennen der transvaginale US und in unklaren Faellen die MRT eingesetzt werden. Die Diagnose entzuendlicher Erkrankungen des weiblichen Genitaltrakts erfolgt in der Regel klinisch. Schnittbildverfahren werden bei therapieresistenten, komplizierten Faellen angewendet. Initial werden benigne Neoplasien des Uterus mit dem transvaginalen US abgeklaert. Eine Verdickung des Endometriums ist dabei ein unspezifischer Befund und kann auf eine Hyperplasie, Polypen oder ...

2001-09-01

154

DoseWatchers - A computer based X ray dose monitoring project in paediatric radiology  

International Nuclear Information System (INIS)

Full text: Introduction. Children, especially premature infants and neonates, are at a much higher risk to obtain an X ray induced disturbance of life - particularly cancer. On the one hand this is due to their longer life expectancy and on the other hand it is due to their higher cell proliferation rate. The paediatric radiology unit of the Inselspital Bern recently installed some of the most advanced X ray equipment nowadays available. It is based on the two latest digital technologies: double read computed radiography (CR) and direct digital radiography (DR). Only the implementation of these digital radiography systems permits the digital acquisition and additionally the analysis of acquired data. The systematic analysis of large amounts of biometric data and exposition data is the basis for further dose reduction and a systematic quality control (QC). Patients are increasingly critical concerning radiation exposure - especially parents regarding their children. Besides an ...

2006-11-13

155

Influence of contrast-enhanced CT and MRI with or without SPIO particles on therapy and therapy costs for patients with focal liver disease; Einfluss von biphasischer Spiral-CT, nativer und eisenoxidverstaerkter MRT auf Therapie und Therapiekosten bei Patienten mit fokalen Leberlaesionen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Evaluation of the diagnostic efficacy and cost-benefit of contrast enhanced CT (CT) and MRI pre- and post-SPIO-particles in focal hepatic disease with consideration of therapeutic outcome. Results: In 34/52 (65.4%) of the cases the correct diagnosis was primarily stated by CT (sensitivity [se.] 85.2%, specificity [sp.] 44.0%). In additional 10/52 of the cases unenhanced MRI (se. 91.4%, sp. 75.0%) enabled correct diagnoses, and in another 6 cases the diagnosis was established only by SPIO-MRI (se. 100%, sp. 86.7%). Considering the possible therapeutic recommendation arising from each modality, CT would have induced needless therapy costs of 191,042 DM, unenhanced MRI of 171,035 DM, and SPIO-MRI of 7,311 DM. In comparison to the real therapy costs of 221,873 DM, this would have corresponded to an unnecessary increase of therapy costs of 86.1%, 77.1%, and 3.3%, respectively. In two cases (91 hemangioma, 1 regenerative nodule) all ...

2000-03-01

156

Whole-body tumor staging: MRI or FDG-PET/CT?; Ganzkoerpertumorstaging: MRT oder FDG-PET/CT  

Energy Technology Data Exchange (ETDEWEB)

Technical innovations such as the availability of movable patient platforms and the introduction of 32-channel systems have made whole-body MRI for tumor staging feasible. In addition, the development of dual-modality PET/CT systems offers the opportunity to perform anatometabolic tumor staging with whole-body coverage in a single session. Based on an increase in patient survival when applying a stage-adapted therapy in different malignant diseases the relevant question relates to the accuracies of whole-body MRI and whole-body PET/CT for TNM staging. This review article addresses whole-body tumor staging with MRI and FDG-PET/CT with special emphasis on diagnostic accuracies for staging different malignant diseases. (orig.) [German] Technische Neuerungen, wie die Verfuegbarkeit beweglicher Tischaufsaetze oder die Einfuehrung von 32-Kanal-Systemen, haben die Ganzkoerperbildgebung mit der MRT ermoeglicht. Die Entwicklung kombinierter PET/CT-Systeme bereitet den Weg ...

2004-09-01

157

What, why, and when we image: considerations for diagnostic imaging and clinical research in the Children's Oncology Group  

Energy Technology Data Exchange (ETDEWEB)

Success in improving treatment outcomes in childhood cancer has been achieved almost exclusively through multicenter and multidisciplinary clinical and applied research over several decades. While biologically rational as well as empirical approaches have led to combination chemotherapy and multimodality approaches to therapy, which have given rise to evidence-based practice standards, similar scientific rigor has not always been as evidently applied to modalities utilized to assess initial disease burden and, more important, response to investigational approaches to therapy. As the empirical approach to therapeutic advances has likely maximized its benefit, future progress will require translation of biologic discovery most notably from the areas of genomics and proteomics. Hence, attempts to improve efficacy of therapy will require a parallel effort to minimize collateral damage of future therapeutic approaches, and such a parallel approach will mandate the ...

2009-02-15

158

Transarterial Chemoembolization (TACE) for Inoperable Intrahepatic Cholangiocarcinoma  

International Nuclear Information System (INIS)

The aim of this retrospective study was to determine the safety and efficacy of chemoembolization (TACE) as palliative treatment for patients with unresectable intrahepatic cholangiocarcinoma (CCA) and to compare the results with those in the literature. Fifteen patients with histology-proven CCA (5 men, 10 women) had received palliative treatment with TACE over a 6-year period. The treatment protocol comprised repeated TACE at a minimum of 8-week intervals. TACE was performed with a mixture of 10 ml Lipiodol and 10 mg mitomycin C injected into the tumor-supplying vessels. Follow-up investigations after 8-10 weeks comprised contrast-enhanced multislice spiral CT and laboratory control. Statistical evaluation included survival analysis using the Kaplan-Meier method. During the investigation period 58 TACEs (3.9 #+-# 3.8; 1-15) were performed in 15 patients. Mean tumor size was 10.8 #+-# 4.6 cm (range, 2.0-18.0 cm). Unifocal tumor disease was diagnosed in eight patients, and multifocal ...

2007-11-01

159

The interpolation damage detection method for frames under seismic excitation  

Science.gov (United States)

In this paper a new procedure, addressed as Interpolation Damage Detecting Method (IDDM), is investigated as a possible mean for early detection and location of light damage in a structure struck by an earthquake. Damage is defined in terms of the accuracy of a spline function in interpolating the operational mode shapes (ODS) of the structure. At a certain location a decrease (statistically meaningful) of accuracy, with respect to a reference configuration, points out a localized variation of the operational shapes thus revealing the existence of damage. In this paper, the proposed method is applied to a numerical model of a multistory frame, simulating a damaged condition through a reduction of the story stiffness. Several damage scenarios have been considered and the results indicate the effectiveness of the method to assess and localize damage for the case of concentrated damage and for low to medium levels of noise in the recorded signals. The main advantage of the proposed ...

2011-10-01

160

The clinical application of positron emission tomography to colorectal cancer management  

International Nuclear Information System (INIS)

Colerectal cancer (CRC) is the second commonest cancer in the Western World. Successful treatment relies significantly on accurate detection and staging of primary disease as well as the early identification of the presence and extent of recurrence. Morphological imaging techniques, particularly computed tomography (CT), are well established and widely available to carry out these tasks in addition to predicting and monitoring response to therapy. This review analyses the current inadequacies for imaging CRC and critically assesses the potential role of functional imaging with positron emission tomography (PET). It was reviewed the current literature, to use the experience from the firs 1000 PET studies carried out at the institution and the perspective of surgical colleagues. It was found little evidence for the use of 2-["1"8F]fluoro-2-deoxy-D-glucose (FDG)-PET for screening asymptomatic individuals and current modalities appear better suited for detection of ...

2001-09-01

161

Taking transport to a higher plane  

Energy Technology Data Exchange (ETDEWEB)

The coal transportation industry has played an integral role in determining coal markets, particularly in recent years, as the industry has evolved from cost-based pricing to market-based pricing. Aggressive pricing by Western rail carriers has caused extensive changes in coal marketing patterns in the Midwest. Multi-modal barge deliveries of Western and Appalachian coals have also played a significant, though lesser, role in changing coal markets. Eastern rail carriers have generally lagged in their aggressive pursuit of new coal markets and, to date, few changes in coal markets have been realised. The historic dominant role of transportation in shaping markets for coal will continue into the future as the utility industry contends with the effects of CAAA compliance and deregulation and as the coal industry contends with regional coal displacements and major imbalances in supply and demand. The dominance of rail transportation in defining coal distribution ...

1994-04-01

162

Structural Insights into the Interaction of the Evolutionarily Conserved ZPR1 Domain Tandem with Eukaryotic EF1A, Receptors, and SMN Complexes  

Energy Technology Data Exchange (ETDEWEB)

Eukaryotic genomes encode a zinc finger protein (ZPR1) with tandem ZPR1 domains. In response to growth stimuli, ZPR1 assembles into complexes with eukaryotic translation elongation factor 1A (eEF1A) and the survival motor neurons protein. To gain insight into the structural mechanisms underlying the essential function of ZPR1 in diverse organisms, we determined the crystal structure of a ZPR1 domain tandem and characterized the interaction with eEF1A. The ZPR1 domain consists of an elongation initiation factor 2-like zinc finger and a double-stranded {beta} helix with a helical hairpin insertion. ZPR1 binds preferentially to GDP-bound eEF1A but does not directly influence the kinetics of nucleotide exchange or GTP hydrolysis. However, ZPR1 efficiently displaces the exchange factor eEF1B from preformed nucleotide-free complexes, suggesting that it may function as a negative regulator of eEF1A activation. Structure-based mutational and complementation analyses reveal a conserved binding ...

2007-01-01

163

Similar Treatment Outcomes for Radical Cystectomy and Radical Radiotherapy in Invasive Bladder Cancer Treated at a United Kingdom Specialist Treatment Center  

International Nuclear Information System (INIS)

Purpose: To conduct a retrospective analysis within a large university teaching hospital, comparing outcomes between patients receiving either radical surgery or radiotherapy as curative treatment for bladder cancer. Patients and Methods: Between March 1996 and December 2000, 169 patients were treated radically for muscle-invasive bladder cancer. Data were collected from patient notes. Statistical analyses were performed using Kaplan-Meier methods and Cox proportional hazards regression analysis to compare radiotherapy and surgical outcome data. Results: There was no difference in overall, cause-specific, and distant recurrence-free survival at 5 years between the two groups, despite the radiotherapy group being older (median age, 75.3 years vs. 68.2 years). There were 31 local bladder recurrences in the radiotherapy group (24 solitary), but there was no significant difference in distant recurrence-free survival. In a more recent (2002-2006) cohort, the median age of radiotherapy ...

2008-02-01

164

Radiotherapy for brain metastases from renal cell cancer. Should whole-brain radiotherapy be added to stereotactic radiosurgery? Analysis of 88 patients  

International Nuclear Information System (INIS)

Purpose: To evaluate the role of stereotactic radiosurgery (SRS) and whole-brain radiotherapy (WBRT) for the treatment of brain metastases in patients with renal cell cancer (RCC). Patients and methods: 88 patients were treated with either SRS (n = 51) or SRS + WBRT (n = 17) for one to three lesions, or with WBRT (n = 20) for more than three brain metastases. Overall survival (OS), intracerebral control (IC) and local control (LC) were retrospectively analyzed. Six potential prognostic factors were assessed: age, gender, number of brain metastases, extracerebral metastases, recursive partitioning analysis (RPA) class, and interval from tumor diagnosis to irradiation. Results: The median times for OS, IC, and LC from the time of diagnosis were 11, 9, and 10 months. The median OS times for SRS, SRS + WBRT, and WBRT were 12, 16, and 2 months. Addition of WBRT to the SRS improved IC (p = 0.032) but not OS (p = 0.703). On multivariate analyses, improved OS was associated with the absence of ...

2010-04-01

165

Radiotherapy and multimodality management of cholangiocarcinoma  

International Nuclear Information System (INIS)

Purpose: To evaluate the results of radiotherapy in cholangiocarcinoma patients managed with various combinations of chemotherapy and surgical resection with selective liver transplantation. Methods and Materials: From January 1990 to December 1995, 61 patients with histologically confirmed biliary duct adenocarcinoma were seen in the Radiation Oncology Department of the University of Pittsburgh. Median follow-up was 22 months (1 to 91 months). The extent of surgery was complete resection in 23 patients (including 17 with orthotopic liver transplant), partial resection in 4, and biopsy in 34. All patients had radiotherapy; median dose was 49.5 Gy. Thirty patients received chemotherapy: 5-fluorouracil (5-FU)-leucovorin with interferon alpha (IFN#alpha#) in 27, and taxol in 3. Results: The median survival was 20 months (95% CI 15-25 months). The 5-year actuarial survival was 23.8 #+-# 6.8%. The only significant variable in multivariate analysis was achieving a complete resection with ...

1999-04-01

166

Radiosurgery for metastatic brain tumors  

International Nuclear Information System (INIS)

Stereotactic radiosurgery (SRS) precisely delivers high-dose radiation to a small target (usually less than 3-4 cm in diameter), in a single session with steep dose-fall, employing various radiation methods. SRS provides good tumor control for small brain metastases from various primary cancers, with minimal untoward effects on surrounding normal brain. This excellent tumor control prevents neurological death and maintains good activity of daily life. Although surgery with whole-brain radiation therapy (WBRT) remains an important option for patients with a solitary brain metastasis, SRS with or without WBRT should be considered in patients with a limited number of small tumors and a good prognosis. Many reports, as well as both retrospective and prospective reviews, have shown WBRT before or after SRS to improve local control and reduce new distant lesion emergence. However, upfront WBRT does not improve survival. There are two major delivery techniques, Gamma Knife (GK; Elekta AB, ...

2009-08-01

167

Quantitative bone and 67Ga scintigraphy in the differentiation of necrotizing external otitis from severe external otitis  

Energy Technology Data Exchange (ETDEWEB)

Qualitative technetium Tc 99m bone scintigraphy using phosphate compounds and gallium 67 scintigraphy were described as a helpful means in diagnosing necrotizing external otitis (NEO). They were, however, claimed to be nonspecific. Quantitative Tc 99m methylene diphosphonate bone scintigraphy and gallium 67 scintigraphy were performed in eight patients with NEO and in 20 patients with severe external otitis, in order to prove usefulness of scintigraphy in the diagnosis of NEO. Ratios of lesion to nonlesion for bone scintigraphy were 1.67 {plus minus} 0.16 in patients with NEO and 1.08 {plus minus} 0.09 in patients with severe external otitis, and for gallium 67 scintigraphy they were 1.35 {plus minus} 0.24 in NEO patients and 1.05 {plus minus} 0.03 in patients with severe external otitis. There was no difference in uptake between diabetic patients with severe external otitis and nondiabetic patients. The scintigraphic studies were also evaluated using a qualitative scoring method ...

1991-06-01

168

Quantitative bone and 67Ga scintigraphy in the differentiation of necrotizing external otitis from severe external otitis  

International Nuclear Information System (INIS)

Qualitative technetium Tc 99m bone scintigraphy using phosphate compounds and gallium 67 scintigraphy were described as a helpful means in diagnosing necrotizing external otitis (NEO). They were, however, claimed to be nonspecific. Quantitative Tc 99m methylene diphosphonate bone scintigraphy and gallium 67 scintigraphy were performed in eight patients with NEO and in 20 patients with severe external otitis, in order to prove usefulness of scintigraphy in the diagnosis of NEO. Ratios of lesion to nonlesion for bone scintigraphy were 1.67 #+-# 0.16 in patients with NEO and 1.08 #+-# 0.09 in patients with severe external otitis, and for gallium 67 scintigraphy they were 1.35 #+-# 0.24 in NEO patients and 1.05 #+-# 0.03 in patients with severe external otitis. There was no difference in uptake between diabetic patients with severe external otitis and nondiabetic patients. The scintigraphic studies were also evaluated using a qualitative scoring method (scores 0 to +4), according to the ...

169

Proceedings of clinical SPECT [single photon emission computed tomography] symposium  

International Nuclear Information System (INIS)

It has been five years since the last in-depth American College of Nuclear Physicians/Society of Nuclear Medicine Symposium on the subject of single photon emission computed tomography (SPECT) was held. Because this subject was nominated as the single most desired topic we have selected SPECT imaging as the basis for this year's program. The objectives of this symposium are to survey the progress of SPECT clinical applications that have taken place over the last five years and to provide practical and timely guidelines to users of SPECT so that this exciting imaging modality can be fully integrated into the evaluation of pathologic processes. The first half was devoted to a consideration of technical factors important in SPECT acquisition and the second half was devoted to those organ systems about which sufficient clinical SPECT imaging data are available. With respect to the technical aspect of the program we have selected the key areas which demand awareness and ...

1986-09-22

170

Multiple courses of high-dose total skin electron beam therapy in the management of mycosis fungoides  

International Nuclear Information System (INIS)

Purpose: A retrospective analysis was undertaken to determine the indications for, the efficacy of, and the long-term complications of two courses of total skin electron beam therapy for mycosis fungoides. Methods and Materials: A retrospective analysis of 15 patients with the pathologic diagnosis of mycosis fungoides treated in the Department of Radiation Oncology at Stanford University Medical Center between 1968 and 1990 was performed. All patients received two courses of high-dose electron beam therapy to the skin. The mean dose for the total skin treatment for the first course was 32.6 Gy and 23.4 Gy for the second course of treatment. Results: Following the first course of total skin electron beam therapy, 11 of 15 had a complete response, with a mean duration of 11.6 months. All patients received adjuvant therapies between the first and second courses of high-dose total skin electron beam therapy. The mean interval between the first and the second courses of therapy was 41.3 ...

1995-07-30

171

Medical treatment of nystagmus and ocular motor disorders.  

Science.gov (United States)

An increased compendium of drugs useful in ocular motor system dysfunction has expanded our capacity to treat selected ocular motility disorders. Adjunctive therapeutic modes (e.g., Fresnel prisms and orthoptic exercises) can also be beneficial. PAN and see-saw nystagmus can be treated with baclofen. Downbeat nystagmus may respond to clonazepam therapy, and prisms may help if the nystagmus can be modified with convergence. Congenital nystagmus may respond minimally to drugs (e.g., baclofen), but prisms or surgical procedures, or both, are still the primary treatment modalities. Innovar may be helpful in patients with severe, incapacitating vestibular disorders, and scopolamine alone or in combination with promethazine may be beneficial in patients with milder ambulatory acute peripheral vestibular disorders. Benign positional vertigo is best treated initially with positional exercises before drug therapy is instituted. Opsoclonus and ocular flutter have been ...

1986-01-01

172

MRI-based N-staging in esophageal cancer  

International Nuclear Information System (INIS)

Purpose: For planning the therapeutic strategies and estimating the prognosis in esophageal cancer, N-staging is very important. To date, MRI still is of minor importance as imaging modality of the mediastinum despite promising developments in the past, like ECG-gating or 'averaging' sequences, e.g. LOTA (Long-term averaging), which facilitate mediastinal and thoracic MR-imaging. In a prospective approach, the value of MRI based N-staging was examined with respect to LOTA-sequences. Material and Methods: Within from weeks prior to esophagectomy, standardized MRI of the esophagus was performed in 15 patients (10 squamous-cell-carcinomas and 5 adenocarcinomas) using a 1.5 T whole body scanner. Imaging quality was classified based on depiction of aortic wall or tracheal wall layers. Criteria for malignant infiltration were a diameter of more than 15 mm or a round appearance of a lymph node together with GD-DTPA enhancement. All data were blinded and separately read by ...

2002-10-01

173

MR findings in cases of suspected impacted fracture of the femoral neck  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate MR imaging of the hip in patients with a clinically suspected impacted fracture of the femoral neck in cases where conventional plain films show negative or equivocal findings. Material and Methods: Twenty-seven such patients were prospectively examined by MR imaging with a 1.0 T unit, within 24 hours of admittance to hospital. A coronal T1-weighted turbo spin-echo sequence (n=27), and a coronal STIR sequence (n=25) or a coronal T2-weighted turbo spin-echo fast saturation sequence (n=2) were used. The evaluations were made by 2 radiologists with experience in musculoskeletal radiology. Results: There were 6 patients with a petrochanteric fracture, 2 without and 4 with slight displacement. Five patients had an impacted fracture of the femoral neck, and 3 had a fracture of the superior pubic bone. Of 2 patients with advanced arthrosis, i had an impacted femoral neck fracture and the other a nondisplaced intertrochanteric fracture. There was 1 patient who had ...

1997-09-01

174

Lung perfusion scintigraphy in the diagnosis of peripheral pulmonary stenosis in patients after repair of Fallot tetralogy  

International Nuclear Information System (INIS)

The frequency of peripheral pulmonary artery stenosis in patients after surgical repair of tetralogy of Fallot (TOF) ranges from 20 to 40%. This can be either primary or secondary to the surgical intervention. The influence of resulting lung perfusion alterations on the life quality of patients is difficult to predict. The aim of this study was to compare the utility of the diagnostic procedures in this group of patients, with particular focus on lung perfusion scintigraphy. This study comprised 104 patients who underwent repair of TOF at ages from 5 months to 25 years. The patients have been followed up for from 4.2 to 25 years. On the basis of chest X-ray peripheral pulmonary artery stenosis was suspected in 11 patients, in 12 on the basis of echocardiography examination. Lung perfusion scintigraphy has been performed on 87 patients. The disturbances in lung perfusion (mostly in the left lung) were show by means of lung perfusion scintigraphy in 43 (49%) of patients. In 27 of them ...

175

Longitudinal changes in extended roles in radiography  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The purpose of this research was to identify the extent and scope of changes to radiography practice. Method: Questionnaires were sent to radiology managers at acute National Health Service (NHS) hospitals in 2000 as a follow-up to an initial survey conducted in 1998. Information was sought on region, teaching/non-teaching status, the nature of extended role tasks undertaken and the year in which these tasks were first undertaken. Results: Some 172 questionnaires were returned from a total of 253 dispatched (68%). In 161 hospitals radiographers administered intravenous injections and performed barium enemas in 119 hospitals, while a red-dot system was in operation in 141 hospitals. Reporting by radiographers had increased since 1998. Replies indicated that, at 124 hospitals, radiographers were reporting in ultrasound. Skeletal reporting was the second most-frequently-reported activity, with 63 hospitals indicating that radiographers reported in this ...

2002-11-01

176

Influence of photodynamic therapy on cell cycle perturbations of the HT-29 cells with modulated 5-lipoxygenase pathway  

International Nuclear Information System (INIS)

One rationale proposals to increase the efficiency of PDT is to combine photo-sensitization with other treatment modalities, including modulation of arachidonic acid metabolism. In combine treatment we examined the effects of 48 h and 24 h pre-treatment of cells with 5- lipoxygenase inhibitor MK-886 prior to photoactivation of hypericin on cell cycle distribution and DNA synthesis. All parameters were examined 24 hours after hypericin activation. Pre-treatment of HT-29 with 5-lipoxygenase inhibitor MK-886 followed by PDT resulted in most significant effects on cell cycle perturbations. Administration of MK-886 alone as well as combination of low doses MK-886 with hypericin induced S phase accumulation. Increasing of MK-886 concentration induced massive changes in the cell cycle progression. Pre-treatment of HT-29 cells with MK-886 alone (15 #mu#M; - 48 h) caused accumulation of cells in S-phase (58 % in S-phase and 36 % in G_0/G_1 phase). However, after followed ...

2006-05-01

177

High-End CT for clinical and scientific applications; High-End-CT im klinischen und wissenschaftlichen Einsatz  

Energy Technology Data Exchange (ETDEWEB)

The enhancements described of high-performance CT systems of latest design have again confirmed the importance of CT systems for acute and selective diagnostic imaging. Higher availability, shorter exposure times, and better applicability and handling for examination of poly-traumata patients or patients of intensive care departments are some of the advantages achieved with CT systems which demonstrate CT system efficiency in addition to MRI, which for specific examinations will remain the modality of first choice for diagnostic evaluation. The Tomoscan Av-E presented here was able to answer all relevant diagnostic questions appearing in routine diagnostics and scientific work. For patients, examinations using the spiral CT technique also offers significant advantages. (orig./CB) [Deutsch] Durch die dargestellten Verbesserungen bei Hochleistungs-CT-Systemen neuester Bauart wurde die Bedeutung der CT fuer die akute und selektive Diagnostik erneut bestaetigt. Bessere ...

1997-12-01

178

Ewing's sarcoma treatment in Scandinavia 1984-1990. Ten-year results of the Scandinavian sarcoma group protocol SSGIV  

International Nuclear Information System (INIS)

A report on the long-term follow up of the first cooperative Scandinavian Sarcoma Group study in Ewing's sarcoma of bone is presented. Fifty-two previously untreated patients entered the study between 1984 and 1990. Half of the tumors were located in the extremities and one quarter in the pelvis. The combined modality treatment consisted of 5 cycles of chemotherapy - including vincristine, methotrexate, doxorubicin, cyclophosphamide, bleomycin and dactinomycin. The first two cycles were followed by local resection or amputation in 35 patients and by radiotherapy alone in 17 patients. When surgery was not performed, was incomplete or yielded poor margins radiotherapy was given at a dose of 40-60 Gy. Local tumor relapses developed in 10 patients and in all but one patient were accompanied by metastatic disease. Five patients had metastasis at diagnosis and distant metastases developed after primary treatment in 27 patients after a median of 14 months. The median ...

179

Diagnostic value of immediate CT after chemoembolization in patients with hepatocellular carcinoma: comparison with 2-3 week delayed CT  

Energy Technology Data Exchange (ETDEWEB)

Lipiodol CT is a important modality for the diagnosis of hepatocellular carcinoma and compared is usually performed at 2-3 week after Lipiodol injection. Therefore, we assessed and the diagnostic value and merits of immediate CT after chemoembolization from there of 2-3 week delayed Lipiodol CT. Thirty three cases of chemoembolization which were performed both immediate CT after chemoembolization and 2-3 week delayed Lipiodol CT were reviewed retrospectively. They were divided into four grades according to pattern of lipiodol uptake by three radiologists. The diagnostic value of immediate Lipiodol CT was compared to delayed Lipiodol CT. Grade 0 was two cases(3.0%) and Grade 1 was seven cases(21.2%). In the cases of Grade 2(23/33, 69.7%), tumor uptake could be dishing wished from parenchymal uptake of Lipiodol by its density and pattern, Tumor uptake showed dense and homogeneous pattern, but parenchymal uptake revealed less dense and hepatogram-like wedge shaped ...

1995-08-15

180

Contrast-enhanced helical CT in sigmoid diverticulitis. Findings and impact on diagnosis and treatment; Ruolo della tomografia computerizzata spirale nella diverticolite del sigma e implicazioni diagnostico-terapeutiche  

Energy Technology Data Exchange (ETDEWEB)

Aim of this retrospective study was to assess the capability of contrast-enhanced helical computerised tomography (CT) in sigmoid diverticulitis, especially relative to selection of the appropriate treatment. The findings of 41 patients were reviewed from 1998 to 1999 June. Contrast-enhanced helical CT is the imaging modality of choice in assessing mild or severe acute diverticulitis because it provides useful information for appropriate treatment planning in the emergency setting. This technique is most useful in questionable cases and in patients with suspected severe diverticulitis where a choice must be made between different treatment options. [Italian] Scopo di questo studio retrospettivo e' illustrare i molteplici aspetti radiologici della flogosi diverticolare sigmoidea con tomografia computerizzata (TC) spirale, con specifico riguardo alle implicazioni terapeutiche che scaturiscono dall'analisi e dal confronto dei reperti TC con i ...

2000-03-01

181

Comparison of helmet-mounted display designs in support of infantry wayfinding  

Science.gov (United States)

The Canadian Soldier Information Requirements Technology Demonstration (SIREQ TD) soldier modernization research and development program has conducted experiments to help determine the types and amount of information needed to support wayfinding across a range of terrain environments, the most effective display modality for providing the information (visual, auditory or tactile) that will minimize conflict with other infantry tasks, and to optimize interface design. In this study, seven different visual helmet-mounted display (HMD) designs were developed based on soldier feedback from previous studies. The displays and an in-service compass condition were contrasted to investigate how the visual HMD interfaces influenced navigation performance. Displays varied with respect to their information content, frame of reference, point of view, and display features. Twelve male infantry soldiers used all eight experimental conditions to locate bearings to waypoints. From a ...

2003-09-01

182

Comparative accuracy of Computed Tomography and lymphoangiography in detecting lymph node metastases from epithelial cancer of the ovary  

International Nuclear Information System (INIS)

The accuracy is investigated of both lymphangiography and CT in detecting lymph nodes metastases in 59 patients evaluated preoperatively and subsequently submitted to surgery with selective/systemic pelvic and paraaortic lymphadenectomy. CT accuracy was also investigated in 46 patients with a clinically suspected relapse of ovarian cancer (verified by means of clinical and/or CT follow-up in 36 patients, by laparotomy in 7, by fine-needle biopsy in 1 and by necroscopy in the last 2). In the first group (previously untreated patients) the overall results in the pelvis were, respectively, for lymphangiography and CT: 94.9% vs 89.8% accuracy, 86.6% vs 60% sensitivity, 97.7% vs 100% specificity, and 92.8% vs 100%, 95.5% vs 88% positive and negative predictive values. In the paraaortic region the results were: 89.1% vs 86.5% accuracy, 73.3% vs 66.6% sensitivity, 100% specificity for both techniques, 100% positive predictive value, and 84.6% vs 81.5% negative predictive value. In the second ...

1991-01-01

183

A wirelessly powered and controlled device for optical neural control of freely-behaving animals.  

Science.gov (United States)

Optogenetics, the ability to use light to activate and silence specific neuron types within neural networks in vivo and in vitro, is revolutionizing neuroscientists' capacity to understand how defined neural circuit elements contribute to normal and pathological brain functions. Typically, awake behaving experiments are conducted by inserting an optical fiber into the brain, tethered to a remote laser, or by utilizing an implanted light-emitting diode (LED), tethered to a remote power source. A fully wireless system would enable chronic or longitudinal experiments where long duration tethering is impractical, and would also support high-throughput experimentation. However, the high power requirements of light sources (LEDs, lasers), especially in the context of the extended illumination periods often desired in experiments, precludes battery-powered approaches from being widely applicable. We have developed a headborne device weighing 2 g capable of wirelessly receiving power using a ...

2011-06-23

184

166Ho-HA evaluation as therapeutic agent for rheumatoid arthritis treatment  

International Nuclear Information System (INIS)

Aim: Rheumatoid arthritis is a limiting disease having, among its pathological features, the inflammation of synovial tissue with progressive and later destruction of the articulation. This leads to joint deformation and loss of its function, generating pain and reducing the mobility of the affected articulation. The aim was to evaluate "1"6"6Ho-Hydroxyapatite ("1"6"6 Ho-HA) as potential radiopharmaceutical for the symptomatic treatment of chronic and acute arthritis. Materials and Methods: Holmiun-166 was produced by irradiation of Ho_2O_3 at La Reina Research Reactor, Nuclear Chilean Energy Commission. Hydroxyapatite was in-house synthesized. Its labelling and quality controls follows the internationally accepted procedures. An antigen's arthritis was induced to eight New Zealand rabbits with the "1"6"6 Ho-HA radiochemical being administered thereafter in two dosage modalities (single and double). The compound therapeutic efficiency was evaluated based upon ...

2002-09-01

185

Transport volume of other radioactive materials in the Federal Republic of Germany in the fields of application of research, medicine and technology; Befoerderungsaufkommen sonstiger radioaktiver Stoffe in der Bundesrepublik Deutschland im Anwendungsbereich Forschung, Medizin und Technik  

Energy Technology Data Exchange (ETDEWEB)

The transport-relevant basic data recorded within the framework of a federation-wide transport data survey made in 1986 are the best-founded source at present for determining the transport volume of other radioactive materials in different economic areas of the Federal Republic of Germany. Due to the high recording rates, a sufficiently complete survey can be provided in particular with regard to the transport volume (e.g.transports/consignments/cargos, transport distance) - with the exception of transport by ship - for the ranges of application in reserach, medicine and technology. However, as regards the radiologically relevant basic data and transport modalities, the information supplied by the transporting agencies is incomplete. A table gives a comprehensive survey of type and scope of the transport volume of other radioactive materials in the Federal Republic of Germany (excluding the GDR) for transport by road, rail and air. The table also includes data on ...

1994-08-01

186

The efficacy of low-dose radiation therapy and surgical resection for Ewing's sarcoma  

International Nuclear Information System (INIS)

Purpose: To evaluate the effect of low-dose radiation therapy and surgery on local control in patients with Ewing's Sarcoma. Materials and Methods: Between 1979 and 1995 24 patients (ages 4-47) with Ewing's sarcoma were treated with combined modality therapy that included multi agent chemotherapy, surgical resection, and radiation therapy. Twelve patients had metastatic disease at the time of presentation (pleura = 3, lung = 5, bone 4). Tumor location was central in 16 and peripheral in 8. Multi agent chemotherapy consisted of vincristine/actinomycin D/cyclophosphamide/doxorubicin in 19. The same agents with the addition of ifosfamide and etoposide were given in 5. The extent of resection was considered to be radical in 14 and of the 16 patients who received preoperative chemotherapy, 5 were found to have a pathologic complete response. All patients with lung metastases at diagnosis received whole-lung irradiation to 1400 cGy in 10 fractions. Radiation therapy to ...

1996-09-01

187

Study on dose distribution of therapeutic proton beams with prompt gamma measurement  

Energy Technology Data Exchange (ETDEWEB)

The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma distribution was compared to the dose distribution measured by an ionization chamber at three different energies of 100, 150, ...

2007-03-15

188

Role of positron emission tomography-computed tomography in staging and early chemotherapy response evaluation in children with neuroblastoma  

International Nuclear Information System (INIS)

To evaluate the role of positron emission tomography-computed tomography (PET-CT) in staging and determining early treatment response to chemotherapy in children with neuroblastoma (NB) and its correlation with the final outcome. Patients and Methods: Seventeen patients of NB with mean age of 51.5 months (age range 2-132 months; 14 males, 3 females) underwent serial "1"8F-fluorodeoxyglucose (FDG) PET-CT imaging. All 17 patients were for staging before any treatment. Twelve of 17 patients underwent "1"3"1I meta-iodobezylguanidine (MIBG) scan and bone scan. MIBG uptake was seen in the primary lesion in 11/12 patients. MIBG uptake in bones was seen in 3/12 patients. All bone lesions were concordant on MIBG and bone scan. Early response to chemotherapy was evaluated after two cycles using PET-CT. A 30% reduction in longest diameter was taken as cut-off value for response on CT based on the response evaluation criteria in solid tumors criteria. Response on PET-CT was assessed using ...

189

Multi-modality treatment of primary nonresectable intrahepatic cholangiocarcinoma with "1"3"1I anti-CEA--a Radiation Therapy Oncology Group Study  

International Nuclear Information System (INIS)

Thirty-seven patients with primary nonresectable intrahepatic cholangiocarcinoma (57% with prior treatment and/or metastasis) were prospectively treated with external radiation, chemotherapy, and "1"3"1I labelled anti-CEA. Therapy began in all trials with whole liver irradiation (21.0 Gy, 3.0 Gy/Fx, 4 days/week, 10 MV photons) with alternate treatment day chemotherapy (Adriamycin, 15 mg + 5-FU, 500 mg). One month after external beam therapy, chemotherapy was given (Adriamycin, 15 mg + 5-FU, 500 mg) followed the next day by the first administration of "1"3"1I anti-CEA. The treatment schedule used was 20 mCi day 0; 10 mCi day 5 as an outpatient. This schedule was derived from tumor dose estimates which indicated that 20 mCi (8-10 mCi/mg IgG) was sufficient to achieve tumor saturation with a tumor effective half-life of 3 to 5 days, depending upon the species of animal from which the antibody was obtained. The median tumor dose for the 20 mCi + 10 mCi regimen was 6.2 Gy. Antibody therapy ...

190

Multi-modality imaging of uveal melanomas using combined PET/CT, high-resolution PET and MR imaging  

Energy Technology Data Exchange (ETDEWEB)

We investigated the efficacy of combined FDG-PET/CT imaging for the diagnosis of small-size uveal melanomas and the feasibility of combining separate, high-resolution (HR) FDG-PET with MRI for its improved localization and detection. Patients, methods: 3 patients with small-size uveal melanomas (0.2-1.5 ml) were imaged on a combined whole-body PET/CT, a HR brain-PET, and a 1.5 T MRI. Static, contrast-enhanced FDG-PET/CT imaging was performed of head and torso with CT contrast enhancement. HR PET imaging was performed in dynamic mode 0-180 min post-injection of FDG. MRI imaging was performed using a high-resolution small-loop-coil placed over the eye in question with T2-3D-TSE and T1-3D-SE with 18 ml Gd-contrast. Patients had their eyes shaded during the scans. Lesion visibility on high-resolution FDGPET images was graded for confidence: 1: none, 2: suggestive, 3: clear. Mean tumour activity was calculated for summed image frames that resulted in confidence grades 2 and 3. Whole-body ...

2008-07-01

191

Modulation of neuronal differentiation by CD40 isoforms  

International Nuclear Information System (INIS)

Neuron differentiation is a complex process involving various cell-cell interactions, and multiple signaling pathways. We showed previously that CD40 is expressed and functional on mouse and human neurons. In neurons, ligation of CD40 protects against serum withdrawal-induced injury and plays a role in survival and differentiation. CD40 deficient mice display neuron dysfunction, aberrant neuron morphologic changes, and associated gross brain abnormalities. Previous studies by Tone and colleagues suggested that five isoforms of CD40 exist with two predominant isoforms expressed in humans: signal-transducible CD40 type I and a C-terminal truncated, non-signal-transducible CD40 type II. We hypothesized that differential expression of CD40 isoform type I and type II in neurons may modulate neuron differentiation. Results show that adult wild-type, and CD40"-"/"- deficient mice predominantly express CD40 type I and II isoforms. Whereas adult wild-type mice express mostly CD40 type I in ...

2008-05-02

192

MR imaging guidance and monitoring of focal thermotherapies. A review; Steuerung und Monitoring von fokalen Thermotherapien mit der Magnetresonanztomographie. Ein Ueberblick  

Energy Technology Data Exchange (ETDEWEB)

Minimally invasive thermotherapies for focal tissue destruction on the basis of laser-, microwave-, focused ultrasound-, or cryogeninduced changes of tissue temperature represent an alternative to surgical tissue ablation, particularly in the treatment of tumors. The thermotherapy modalities listed necessitate indirect guidance and monitoring, since they often do not lend themselves to immediate visual control. In the brain, in head and neck tumors, in the liver, and in the prostate, MRI reliably and accurately delineates both the positions of interstitial thermotherapy applicators and - in contrast-enhanced, T1-weighted images - the perfusion defects in tissue necrosis induced by thermotherapy. The transfer of results of in-vitro and in-vivo model studies to assess interstitial temperature and lesion development during thermotherapy to the actual treatment of patients, however, is still in an initial phase. Further development of both rapid MRI sequences and MRI ...

1998-03-01

193

Inflammatory spine disease as a cause of back pain; Entzuendliche Wirbelsaeulenerkrankungen als Ursache fuer Rueckenschmerzen  

Energy Technology Data Exchange (ETDEWEB)

The aim of this review is to evaluate the role of inflammatory spine disease in patients with chronic back pain. The contribution of imaging modalities for the diagnostic evaluation of back pain is discussed. A systematic literature search based on the classification of seronegative spondyloarthropathies and rheumatoid arthritis was performed. The results of this search and the experiences in a large collective of rheumatological patients are analyzed. The prevalence of rheumatoid arthritis (1-2%) is comparable to that of spondyloarthropathies (1.9%). The etiology of these entities is not fully elucidated. Magnetic resonance imaging is increasingly used for early detection and surveillance of therapy with TNF-{alpha} antagonists. Bone marrow edema, which is only detectable with MRI, represents an early sign of inflammation. Therapy with TNF-{alpha} antagonists is based on clinical and laboratory criteria, and signs of inflammation in MRI. MRI is useful for ...

2006-06-15

194

Diagnosis and therapy of Budd-Chiari syndrome; Diagnostik und Therapie des Budd-Chiari-Syndroms  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Budd-Chiari syndrome is a fairly uncommon disease in Europe. This often leads to its late diagnosis. The syndrome is characterised by portal hypertension and splanchnic congestion due to obstruction of hepatic venous outflow. This paper describes the treatment of three patients with Budd-Chiari syndrome by interventional therapeutic techniques and discusses alternative treatment modalities. Patients and Methods: The first patient presented with veno-occlusive disease and was treated by the placement of a transjugular intrahepatic portosystemic stentshunt. The second patient showed an occlusion of the major hepatic veins. After percutaneous recanalisation, a stent was placed in the right hepatic vein which remained patent. The third patient had a membranous obstruction of the right hepatic vein which was treated by percutaneous balloon dilatation. Results: In all patients the clinical symptoms resolved completely after treatment and no complications were ...

1998-09-01

195

Cutaneous and subcutaneous Ewing's sarcoma: an indolent disease  

International Nuclear Information System (INIS)

Purpose: The occurrence of extraosseous Ewing's sarcoma (ES) in deep soft tissues has been well described, but cases in which this tumor occurs in a primary cutaneous or subcutaneous site have rarely been reported. The superficial variant may be less aggressive than are the more common bony and deep soft tissue counterparts with an apparently favorable outcome. A retrospective review of patients with cutaneous or subcutaneous ES was conducted to analyze outcome and patterns of failure. Methods and Materials: Between July 1985 and March 1997, 14 patients with cutaneous or subcutaneous ES were treated at St. Jude Children's Research Hospital. The median age at presentation was 16 years (range 7-21 years). Anatomic locations included trunk and pelvis (7), upper or lower extremity (4), and head and neck (3). The median size of the lesion was 3 cm (range, 1-12 cm). Thirteen had definitive surgical resections, and one had biopsy of the mass at the time of referral. They were enrolled on ...

2000-01-15

196

Clinically silent heterotaxy with polysplenia syndrome and IVC azygous continuation draining to SVC: CT findings. Case report  

International Nuclear Information System (INIS)

Patients with heterotaxy syndrome often have complex cardiac and extracardiac anomalies requiring further detailed diagnostic evaluation. They often present severe cardiac failure early in life. Newer radiological modalities in the form of spiral computed tomography (CT) and three-dimensional reconstruction of spiral CT allow clear definition of the anatomy of these anomalies. A 59-year-old woman was diagnosed with polysplenia and multiple anomalies in an abdominal ultrasonography (US) during a control medical examination due to a trivial dietary mistake. She was then referred to our institution for further examination of these anomalies and an additional thoraco-abdominal computed tomography (CT) examination. The patient was totally asymptomatic at the time of admission. There was no significant past history and no abnormal laboratory data. We performed abdominal, pelvic and thoracic CT examinations using Somatom Siemens Emotion scanner. Non-enhanced sections were ...

2007-01-01

197

A deterministic partial differential equation model for dose calculation in electron radiotherapy  

International Nuclear Information System (INIS)

High-energy ionizing radiation is a prominent modality for the treatment of many cancers. The approaches to electron dose calculation can be categorized into semi-empirical models (e.g. Fermi-Eyges, convolution-superposition) and probabilistic methods (e.g. Monte Carlo). A third approach to dose calculation has only recently attracted attention in the medical physics community. This approach is based on the deterministic kinetic equations of radiative transfer. We derive a macroscopic partial differential equation model for electron transport in tissue. This model involves an angular closure in the phase space. It is exact for the free streaming and the isotropic regime. We solve it numerically by a newly developed HLLC scheme based on Berthon et al (2007 J. Sci. Comput. 31 347-89) that exactly preserves the key properties of the analytical solution on the discrete level. We discuss several test cases taken from the medical physics literature. A test case with an ...

2010-07-07

198

Web-based training in radiology - student course in the Virtual University of Bavaria; Web-basiertes Training in der Radiologie - Studentenkurs in der Virtuellen Hochschule Bayern (VHB)  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The nint version of the licensing regulation for medical doctors (Approbation Regulation (AR)) sets a benchmark in terms of practical experience, interdigitation of preclinical and clinical studies, interdisciplinary approach, economic efficiency, independence of students, added new teaching and learning modalities, and ongoing evaluation of the progress of the medical students. It is the aim to implement these major points of the AR in a model course for diagnostic radiology and radiation protection within the scope of the Virtual University of Bavaria and test them in practice. Materials and Methods: In cooperation with residents and board certified radiologists, students developed the virtual course 'Web-Based Training (WBT) Radiology' in diagnostic radiology and radiation protection for students in the first clinical semester. A representative target group taken from the student body was asked about the options to get access to the ...

2004-06-01

199

Scientific information and public opinion. Daily press analysis about ozone hole in the years 1996-1997; Informazione scientifica e opinione pubblica. Analisi della stampa quotidiana italiana negli anni 1996-1997 sul tema del buco dell'ozono  

Energy Technology Data Exchange (ETDEWEB)

One of ENEA's many activities consists in dealing with the analysis of information strategies. In this case the analysis concerns an environmental issue, the ozone hole which, in spite of the consideration given by the media, is not sufficiently highlighted, as well as in the case of climate changes issue. A survey of the coverage of four daily newspapers was realized; the time period covered by the analysis spans form January 1996 to December 1997, 77 articles in total. The newspapers involved are: La Repubblica, Il Corriere della Sera, L'Unita' on a national scale, and Il Resto del Carlino on a regional scale. The number of articles analyzed is divided as follows: 26 for the Repubblica, 24 for the Corriere della Sera, 21 for the Unita', 6 for the Resto del Carlino. The purpose of the work was to detect quality and quantity indicators of the Italian press about the ozone hole issue and possible environmental risks conveyed to the public, using the ...

1999-07-01

200

Modern imaging methods for diagnostic evaluation of tumors of the oropharynx and the oral cavity; Moderne bildgebende Methoden bei der Diagnostik von Tumoren des Oropharynx und der Mundhoehle  

Energy Technology Data Exchange (ETDEWEB)

Differentiating a benign from a malignant lesion by information such as density data, or signal intensities or echo gradients, is not possible with CT, nor MRI, nor ultrasonography. Only some lesions show characteristic signs. Inflammations cannot be difscriminated from malignant tumors. CTs of small tumors in particular are so poor in contrast that it is much more difficult to detect tumors or discriminate them from other lesions, as compared to MR images or ultrasonographs. CT does not detect surface tumors, but is more sensitive than MRI or US in detecting discrete cortical bone lesions. The same applies to small calcified tumors. MRI however is most sensitive in detecting tumor volumes in the yellow marrow, and is the best modality for evaluation of extraossal extension of tumors. CT yields better results than MRI if applied for simultaneous screening of lymph node metastases in the lower neck. MRI frequently is spoilt by movement artefacts. High-resolution, ...

1996-11-01

201

HDR and MDR intracavitary treatment for carcinoma of the uterine cervix. A prospective randomized study  

Energy Technology Data Exchange (ETDEWEB)

Aim: Treatment of carcinoma of the uterine cervix by remote afterloading brachytherapy has been accompanied with new isotopes having dose rates different from the classical low-dose rate (LDR) radium source. The dose rate conversion factor from LDR to high-dose rate (HDR) found to be around 0.54 in most studies. As regards medium-dose rate (MDR) brachytherapie, the published data are very few and the experience is still short. In this study the experience of Osaka University Hospital with micro-HDR-Selectron and Selectron-MDR, as a preliminary report of the clinical trial, is presented. Results: The 3-year survival and loco-regional control rates for both modalities were nearly equivalent (62% and 67% for HDR and 68% and 74% for MDR)(totally 45 patients). The cumulative rectal and bladder complication rates were the same in both groups (29% at 3 years), with only 1 patient (MDR-group) developed grade 3 rectal and bladder complication. In this study, point A dose ...

1997-03-01

202

Ganglioneuromas in childhood: MRI and CT characteristics; Ganglioneurome im Kindesalter: CT- und MRT-Charakteristika  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI T{sub 1}-weighted scans the tumors were homogeneous and hypointense, ...

2000-05-01

203

Differential diagnosis of rheumatic diseases; Differenzialdiagnose rheumatischer Erkrankungen  

Energy Technology Data Exchange (ETDEWEB)

Which imaging modalities are appropriate for the Differential diagnosis of Rheumatic diseases. MRI has far most the highest sensitivity and is unequaled in its brilliant presentation of Anatomy and Pathology. But it is sometimes forgotten, that this is at least in part the result of carefully selected sequences, dedicated to the expected result. In a method totally independent of any result, this should not be the case. In contrary this method should be highly standardised and regardless what will be the findings. This is true for Plain X-ray. It will be shown, that already the outer silhouette of the soft parts with different features of swelling, and differences in density and even more - defects or appositions of the bony silhouette in the majority of cases at least will allow to classify the patient for a group of diseases and in many cases will lead to a definite diagnosis. Differential diagnoses like Rheumatoid Arthritis versus Psoriatic Arthritis or simply ...

2006-05-15

204

Decision making information systems and data base management; Applicazioni dei sistemi di supporto alle decisioni manageriali in un ente fortemente decentrato. Sviluppo di un prototipo per la valutazione di nuovi progetti  

Energy Technology Data Exchange (ETDEWEB)

In these years Information Technology has been used in activities that require an intelligent intervention. In this context take placing Decision Support Systems, since they use Information Technology to support users in decision processes, that is problems of logical level greater then problems normally treated by traditional information systems. The purpose of this work is to describe Decision Support Systems specifying what they are, their functionally and structure, identifying, furthermore, user types referred to and interaction modality between them; and to present a prototype of these systems. From a preliminary analyses phase of ENEA being and its Information Systems to understand which topics can be supported by systems of this type, it deals with one of these topics: weighing of new project, finding parameters, or key quantity, that affect and determine decisions. It describes, then, models, conceived form parameters, that permit to the user, through a ...

1997-01-01

205

Helical CT of traumatic injuries of the thoracic aorta; Applicazioni della Tomografia Computerizzata spirale nello studio delle lesioni traumatiche dell'aorta toracica  

Energy Technology Data Exchange (ETDEWEB)

Acute thoracic aortic injuries account for up to 10-20% of fatalities in high-speed deceleration road accidents and have an estimated immediate fatality rate of 80-90%. Untreated survivors to acute trauma (10-20%) have a dismal prognosis: 30% of them die within 6 hours, 40-50% die within 24 hours, and 90% within 4 months. It was investigated the diagnostic accuracy of Helical Computed Tomography (Helical CT) in acute traumatic injuries of the thoracic aorta, and the role of this technique in the diagnostic management of trauma patients with a strong suspicion of aortic rupture. It was compared retrospectively the chest Helical CT findings of 256 trauma patients examined June 1995 through August 1999. Chest Helical CT examinations were performed according to trauma score, to associated traumatic lesions and to plain chest radiographic findings. All the examinations were performed with no intravenous contrast agent administration and the pitch 2 technique. After a previous baseline ...

2000-09-01

206

Comparison of high resolution whole-body MRI using parallel imaging and PET-CT. First experiences with a 32-channel MRI system; Hochaufloesendes Ganzkoerpertumorstaging unter Verwendung paralleler Bildgebung im Vergleich zur PET-CT. Erste Erfahrungen auf einem 32-Kanal-MRT-System  

Energy Technology Data Exchange (ETDEWEB)

To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI scanner (Magnetom Avanto, Siemens Medical Solutions) with a total field of view of ...

2004-09-01

207

Title of paper: the induction of P-53 independent programmed cell death (apoptosis) with ionizing radiation and 5-fluorouracil (5-FU) in the HT-29 human colon carcinoma cell line  

International Nuclear Information System (INIS)

Purpose/Objective: The role of programmed cell death (apoptosis) as a cellular response to cancer therapy such as radiation or chemotherapy is the subject of much study, and manipulation of the apoptotic response in tumor cells may be valuable in the treatment of a variety of cancers. Both p53 dependent and independent apoptotic pathways have been identified; p53 is mutated in at least 50 % of human cancers and a majority of radiation resistant tumors contain p53 mutations. This study is designed to examine the induction of programmed cell death in a human colon carcinoma cell line that possesses two mutated p53 alleles. Ionizing radiation alone, or in combination with the chemotherapeutic drug 5-fluorouracil (5-FU), were used to elicit the apoptotic response. This study will focus on whether these treatments can induce a significant apoptotic response in cells that have mutated p53 alleles. Materials and Methods: HT-29 cells were assessed for clonogenic survival after being plated at ...

1996-09-01

208

MRI-based N-staging in esophageal cancer; N-Staging des Oesophaguskarzinoms mittels MRT unter Verwendung von artefaktreduzierenden LOTA-Sequenzen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: For planning the therapeutic strategies and estimating the prognosis in esophageal cancer, N-staging is very important. To date, MRI still is of minor importance as imaging modality of the mediastinum despite promising developments in the past, like ECG-gating or 'averaging' sequences, e.g. LOTA (Long-term averaging), which facilitate mediastinal and thoracic MR-imaging. In a prospective approach, the value of MRI based N-staging was examined with respect to LOTA-sequences. Material and Methods: Within from weeks prior to esophagectomy, standardized MRI of the esophagus was performed in 15 patients (10 squamous-cell-carcinomas and 5 adenocarcinomas) using a 1.5 T whole body scanner. Imaging quality was classified based on depiction of aortic wall or tracheal wall layers. Criteria for malignant infiltration were a diameter of more than 15 mm or a round appearance of a lymph node together with GD-DTPA enhancement. All data were blinded and ...

2002-10-01