New Reactor Neutrino Experiments besides Double-CHOOZ
Several new reactor neutrino experiments are being considered to measure the parameter theta-13. The current plans for Angra, Braidwood, Daya Bay, KASKA and KR2DET are reviewed. A case is made that, together with Double-CHOOZ, a future world program should include at least three such experiments.
2005-01-01
x - NASA Technical Reports Server
analysis of NaMBT in ethylene glycol-water solutions with high accuracy. It reduces analysis time, requires smaller samples, and is able to detect extremely ...
8862 - NASA Technical Reports Server
Mar 1, 2011 ... analysis of NaMBT in ethylene glycol-water solutions with high accuracy. It reduces analysis time, requires smaller samples, and is able to ...
Energy Technology Data Exchange (ETDEWEB)
At tandem cold rolling mills in Kawasaki Steel, by means of applying newly developed strip longitudinal (rolling) and transverse gauge control systems, high accuracy of thickness of within {+-}0.5 % has been achieved over the full length and full width of cold rolled strip, as gauge accuracy in a coil in longitudinal and transverse directions has become an extremely important quality control item in the manufacturing of cold rolled sheets due to the stricter quality requirements of customers, in recent years. The longitudinal gauge accuracy has been improved by the development of a high-response drive system for a mill mair motor, an all-stands gauge control system and a dynamic set-up control system. The transverse gauge accuracy has been improved by applying a one-side tapered work roll shifting method and the development of an edge drop control system in ...
1999-12-01
Instanton contributions to the $\\tau$ decay widths
Contrary to some previous claims, we find a sizable instanton contribution to the finite energy sum rule used to extract the value of the strong coupling from the measured $\\tau$ decay widths. It is of the same order of magnitude as standard nonperturbative corrections induced by vacuum quark and gluon condensates. Our result indicates that there might be no hierarchy of power corrections in finite energy sum rules at the scale of $\\tau$ mass. Therefore, the standard nonperturbative corrections do not necessarily improve the accuracy of the theoretical predicition, but can rather be used to estimate an intrinsic accuracy of the pure perturbative calculation, which turns out to be rather high on this evidence, of order one percent.
1993-01-01
Continuous measurement of blast-furnace coke moisture
International Nuclear Information System (INIS)
After presenting the advantages of applying neutron moisture gages to the continuous measurement of blast-furnace coke moisture and explaining the factors influencing the measurement accuracy, the necessity of calibrating these devices under flow conditions and the encountered difficulties are discussed. Using statistical methods it has been observed that the main source of calibration errors is the sampling phase. Based on results of mathematical processing, a new calibration method with higher performance - compared with the earlier ones - is proposed. This method allows to achieve high accuracy in a relatively short time. (author).
International Nuclear Information System (INIS)
The accuracy is investigated of both lymphangiography and CT in detecting lymph nodes metastases in 59 patients evaluated preoperatively and subsequently submitted to surgery with selective/systemic pelvic and paraaortic lymphadenectomy. CT accuracy was also investigated in 46 patients with a clinically suspected relapse of ovarian cancer (verified by means of clinical and/or CT follow-up in 36 patients, by laparotomy in 7, by fine-needle biopsy in 1 and by necroscopy in the last 2). In the first group (previously untreated patients) the overall results in the pelvis were, respectively, for lymphangiography and CT: 94.9% vs 89.8% accuracy, 86.6% vs 60% sensitivity, 97.7% vs 100% specificity, and 92.8% vs 100%, 95.5% vs 88% positive and negative predictive values. In the paraaortic region the results were: 89.1% vs 86.5% accuracy, 73.3% vs 66.6% sensitivity, 100% specificity for both techniques, 100% ...
1991-01-01
Energy Technology Data Exchange (ETDEWEB)
Ultrasound tomography is an attractive imaging method for the detection of breast cancer. The complex anatomy of the breast with its different spatial scales and material property contrasts make accurate reconstructions very challenging. This paper proposes a hybrid approach whereby Travel-of-Flight and Diffraction Tomography are combined together to achieve high-resolution and high-accuracy sound-speed reconstructions. The method is validated with several numerical phantoms.
2010-01-01
Modification of SGS system for application to various sized drums
Energy Technology Data Exchange (ETDEWEB)
To dispose the radioactive waste drums, the waste form's integrity and the nuclides inventories must be assured according to the national and site waste acceptance criteria. Because they might be would gravely affected the performance objectives of disposal site. Our national regulation for the waste inventory related to 'Radioactive Waste Acceptance Criteria' requires that the activities of 13 nuclides and gross {alpha} must be measured and the 95 % of nuclides incorporated in the drum must be identified. It is very difficult to measure the radioactivity with accuracy from the regulated waste drum(200L), and have a large error in the analysis results. In present, there are two system, SGS (Segmented Gamma Scanning System) and TGS (Tomographic Gamma Scanning System) for the analysis of radionuclides from the waste drums. In general, it is known that the accuracy of TGS is below 20 % and that of SGS is below 30 %. The ...
2005-11-15
Modification of SGS system for application to various sized drums
International Nuclear Information System (INIS)
To dispose the radioactive waste drums, the waste form's integrity and the nuclides inventories must be assured according to the national and site waste acceptance criteria. Because they might be would gravely affected the performance objectives of disposal site. Our national regulation for the waste inventory related to 'Radioactive Waste Acceptance Criteria' requires that the activities of 13 nuclides and gross #alpha# must be measured and the 95 % of nuclides incorporated in the drum must be identified. It is very difficult to measure the radioactivity with accuracy from the regulated waste drum(200L), and have a large error in the analysis results. In present, there are two system, SGS (Segmented Gamma Scanning System) and TGS (Tomographic Gamma Scanning System) for the analysis of radionuclides from the waste drums. In general, it is known that the accuracy of TGS is below 20 % and that of SGS is below 30 %. The ...
2005-11-01
Isotopic analysis of lithium by hollow cathode excitation
Energy Technology Data Exchange (ETDEWEB)
A method for quick, high-accuracy measurement of lithium isotopes has become necessary in carrying out research on the separation and concentration of lithium isotopes by ion exchange. The present report focuses on the application of a hollow cathode, as excitation source, to emission spectral analysis for lithium isotope measurement. The grating monochromator used incorporates a pressure scanned etalon. With decreased Doppler broadening and pressure broadening, the hollow cathode, used as excitation source, can give narrow spectral lines, permitting good separation among them. To achieve a high accuracy, the emission intensity of the hollow cathode should be maintained as stable as possible relative to time. In particular, the stability of a light source can be affected significantly by the chemical form of the sample. A study is also made here to identify a condition where lithium acetate effluent as-obtained from an ion ...
1990-04-01
Use of high energy radiation component as a reference source for radiometric testing
International Nuclear Information System (INIS)
The possibility of providing high accuracy of absorption and albedo methods of radiometric testing due to the use of high-energy radiation component that has passed through a barrier and gone from it in the opposite direction as a reference source, is considered. It is shown that the use of high-energy component of penetrating radiation as a reference source decreases the device response to the main interference in a much larger degree than its response to the change of measured parameter. Experiments are performed using steel pipes and plates. "2"4"1Am, "1"3"7Cs and "6"0Co are used as sources.
CT colonography: interpretative performance in a non-academic environment
Energy Technology Data Exchange (ETDEWEB)
Aim: To investigate interpretative accuracy and reporting time for radiologists performing computed tomography (CT) colonography in day-to-day non-academic clinical practice. Materials and methods: Thirteen radiologists from seven centres, who were reporting CT colonography in non-academic daily clinical practice, interpreted a dataset of 15 colonoscopically validated cases in a controlled environment. Ten cases had either a cancer or polyp >10 mm; one case had a medium polyp and four were normal. Correct case categorization and interpretation times were compared using analysis of variance to aggregated results obtained from both experienced observers and observers recently trained using 50 cases, working in an academic environment. The effect of experience was determined using Spearman's rank correlation. Results: Individual accuracy was highly variable, range 53% (95% CI 27-79%) to 93% (95% CI 68-100%). ...
2007-05-15
Energy Technology Data Exchange (ETDEWEB)
Forty-five patients with recent cervical hip fractures were included in a prospective, clinical, radiographic and sequential scintimetric study. Striking changes in radionuclide uptake over the entire hip region on the fracture side were found during the first 5 postoperative months. Fractures that healed without complications showed the highest relative femoral head uptake at 1 week and a peak value at 6 weeks, followed by a gradual decline at the subsequent examinations. Fractures with complications (redisplacement, nonunion, or late segmental collapse) showed a lower initial uptake and a more gradual increase and only a slight tendency towards increased uptake after 3 months. The accuracy in predicting nonunion with scintimetric examination alone is high both at 1 and at 6 weeks, and the accuracy is almost equally high with combined scintimetric, radiographic, and clinical assessment 3-5 months ...
1987-01-01
Demonstration experiments of volume measurement technique for large scale input accountancy tank
International Nuclear Information System (INIS)
Tank calibration experiments have been carried out using a mock-up input accountancy tank with the object of developing a high accuracy solution volume measurement technique for Rokkasho Reprocessing Plant (RRP). The experimental parameters such as temperature, solution density, off gas pressure and so on have been fluctuated in the calibration experiments in order to evaluate the influence on the solution volume measurement. As a result, it was confirmed that the solution volume measurement error of the mock-up tank was within #+-#0.04% (at full volume) using careful data correction technique for measured data. For the high accuracy volume measurement at RRP, it is important to correct data properly taking account of the actual conditions such as uncontrollable ambient temperature that are different from the experiment. (author)
2000-12-07
The High-Redshift Neutral Hydrogen Signature of an Anisotropic Matter Power Spectrum
An anisotropic power spectrum will have a clear signature in the 21cm radiation from high- redshift hydrogen. We calculate the expected power spectrum of the intensity fluctuations in neutral hydrogen from before the epoch of reionization, and predict the accuracy to which future experiments could constrain a quadrupole anisotropy in the power spectrum. We find that the Square Kilometer Array will have marginal detection abilities for this signal at z~17 if the process of reionization has not yet started; reionization could enhance the detectability substantially. Pushing to higher redshifts and higher sensitivity will allow highly precise (percent level) measurements of anisotropy.
2011-01-01
International Nuclear Information System (INIS)
The investigation of important wear processes in the railway technique, especially the differentiation of the parameters influencing the wear process, requires extensive test programmes and thus high resolving methods to determine the wear. Radiometric methods enable considerably greater measuring accuracy with the help of the activation of materials than an observation of measurement or measuring changes. (orig./LH).
1975-04-03
Energy Technology Data Exchange (ETDEWEB)
Small-scale methods for determining the reaction rates of explosives that make it possible to predict safe temperatures for using them, and methods for testing the accuracy of these predictions were developed. Each different size and shape of each different explosive has its own critical temperature. The ability to predict these critical temperatures is required before high-energy materials can be used safely.
1981-03-01
Spectrophotometric method, using a ratio-recording ultraviolet-absorption spectrophotometer, permits analysis of NaMBT in ethylene glycol-water solutions with high accuracy. It reduces analysis time, requires smaller samples, and is able to detect extremely small concentrations of mercaptobenzothiazole.
1967-01-01
Digital optical processing system
Energy Technology Data Exchange (ETDEWEB)
Digital optical processing (DOP) was conceived to encompass the advantages of both electronic and optical processors, which are parallelism, flexibility, and high accuracy. The authors discuss the concept of parallelism, how it applies to DOP differently than to electronic parallel processing, and other potential advantages in using DOP. A PLZT memory device is described which can perform a series of logic or memory operations. From several of these PLZT devices a DOP is constructed to illustrate some of its programmability features.
1983-01-01
Energy Technology Data Exchange (ETDEWEB)
For verification of cow fertility a /sup 3/H radioimmunoassay of progesterone in milk and blood plasma was developed. It is of high specificity and accuracy as well. Extraction of progesterone from milk was facilitated by application of alcohol. Suggested differences in milk and plasma progesterone levels between pregnant and nonpregnant cows could be revealed.
1984-01-01
Determination of Y, Ba and Cu in superconductor films by x-ray fluorescence analysis
International Nuclear Information System (INIS)
Radionuclide x-ray fluorescence analysis was used for the determination of Y, Ba and Cu in thin high-temperature superconducting films. Atomic emission ICP spectrometry was used to estimate the precision and accuracy of analytical results. Reasonable agreement between both methods was obtained when a polynomial calibration curve was applied. (author) 4 refs.; 4 tabs.
1994-06-01
Robust curve fitting method for single binding site mass action model of radioimmunoassay
International Nuclear Information System (INIS)
The difficulty and unstability of the parameter estimation of mass action model for radioimmunoassay are the major obstacles to its application in routine work. A unique robust curve fitting method for the mass action model was introduced. large numbers of simulated data were generated with Monte Carlo method to compare the accuracy and robustness of the robust fitting and the least squre fitting (Marquardt method) of the mass action model. The results demonstrated that the new robusst method significantly increased the accuracy and reliability of data processing with the mass action model. It also markedly reduced the influence of outliers in the fitting of RIA data, and it was always 'convergent'. This robust method could also be applied to other mathematical models which can be transformed into high degree equations and no initial estimates are needed for curve fitting.
Nuclear Charge Radius of Lithium-11
Energy Technology Data Exchange (ETDEWEB)
We have determined the nuclear charge radius of 11Li by high-precision laser spectroscopy. The experiment was performed at the TRIUMF-ISAC facility where the 7Li-11Li isotope shift was measured in the 2s to 3s electronic transition using Doppler-free two-photon spectroscopy with a relative accuracy better than 10 5. The accuracy reached in previous experiments on the other lithium isotopes was improved. Most of the isotope shifts measured in the experiment are due to difference in the mass of the nuclei but small contributions are produced by the change in proton distribution, QED and relativistic effects have to be taken into account as well. By comparing the experimental results with sophisticated atomic calculations of the mass dependent effect the nuclear charge radii of the lithium isotopes are found to decrease monotonically from 6Li to 9Li while the nuclear charge radius of 11Li is about 11% larger than that of 9Li.
2006-07-01
Measurement of beta-decay half-lives of short-lived nuclei with Spectrum Multi-Scaler (SMS)
Energy Technology Data Exchange (ETDEWEB)
The half-lives of short-lived nuclei produced by 14 MeV or thermal neutron bombardments were measured with a Ge detector, a Spectrum Multi-Scaler (Laboratory Equipment Corporation SMS-48) and a High-Rate Spectroscopy Amplifier (EG and G ORTEC Model 973) in the multi-scaling mode. The corrections for pile-up and dead-time losses were performed by applying source and pulser methods. The half-lives of {sup 91m}Mo, {sup 97m}Nb, {sup 138}Cs, {sup 139}Ba, {sup 174}Tm and {sup 203m}Pb were determined with accuracy of 0.22-0.6% and the accuracy has been much improved. (author)
1996-03-01
Fundamental aspects of fault location algorithms used in distance protection
Energy Technology Data Exchange (ETDEWEB)
Considers fundamental problems involved in the precise location of faults on high-voltage transmission lines. The influence of pre-fault load on the distance-to-fault measurement problem is analysed and a new method of accounting for load effects is presented. Two of the algorithms considered are precise, containing no simplifyng assumptions and their overall accuracy is limited only by the accuracy of digital impedance relays at both ends of the protected circuit. A third algorithm presents a new approach to the fault location problem, which requires digital impedance relays at one end only of a transmission line. The procedures described are applicable to any system arrangement and are suitable for a wide range of fault resistance values.
1986-09-01
Extracting mining subsidence land from remote sensing images based on domain knowledge
Energy Technology Data Exchange (ETDEWEB)
Extracting mining subsidence land from remote sensing (RS) images is one of important research contents for environment monitoring in mining area. The accuracy of traditional extracting models based on spectral features is low. In order to extract subsidence land from RS images with high accuracy, some domain knowledge should be imported and new models should be proposed. This paper, in terms of the disadvantage of traditional extracting models, imports domain knowledge from practice and experience, converts semantic knowledge into digital information, and proposes a new model for the specific task. By selecting the Luan mining area as a study area, this new model is tested based on GIS and related knowledge. The result shows that the proposed method is more precise than traditional methods and can satisfy the demands of land subsidence monitoring in mining area. 10 refs., 4 figs., 1 tab.
2008-06-15
System identification refers to estimation of process parameters and is a necessity in control theory. Physical systems usually have varying parameters. For such processes, accurate identification is particularly important. Online identification schemes are also needed for designing adaptive controllers. Real processes are usually of fractional order as opposed to the ideal integral order models. In this paper, we propose a simple and elegant scheme of estimating the parameters for such a fractional order process. A population of process models is generated and updated by particle swarm optimization (PSO) technique, the fitness function being the sum of squared deviations from the actual set of observations. Results show that the proposed scheme offers a high degree of accuracy even when the observations are corrupted to a significant degree. Additional schemes to improve the accuracy still further are also proposed and ...
2008-01-01
Quantitative assessment of mineral content in metacarpal bone with Fuji computed radiography
Energy Technology Data Exchange (ETDEWEB)
A new microdensitometry method for quantitative assessment of bone mineral content using Fuji computed radiography (FCR) was developed and the results were compared with those obtained by the conventional film-screen method. Using both methods, X-ray pictures of the 2nd metacarpal bone were taken with a reference aluminum step wedge in nine normal subjects and nine parameters representing the width and density of bone marrow and cortex were calculated in middle of the bone shaft. Interobserver reproducibility assessed for three parameters was significantly higher in the FCR method than the conventional one. The value of {Sigma}GS computed by the FCR method, that is equivalent to the net bone density of the transverse section of the shaft, showed higher correlation with the one obtained by computed tomography in comparison with the conventional method. In our FCR method, moreover, interobserver reproducibility and accuracy was improved by employing automatic ...
1990-05-01
Quantitative assessment of mineral content in metacarpal bone with Fuji computed radiography
International Nuclear Information System (INIS)
A new microdensitometry method for quantitative assessment of bone mineral content using Fuji computed radiography (FCR) was developed and the results were compared with those obtained by the conventional film-screen method. Using both methods, X-ray pictures of the 2nd metacarpal bone were taken with a reference aluminum step wedge in nine normal subjects and nine parameters representing the width and density of bone marrow and cortex were calculated in middle of the bone shaft. Interobserver reproducibility assessed for three parameters was significantly higher in the FCR method than the conventional one. The value of #SIGMA#GS computed by the FCR method, that is equivalent to the net bone density of the transverse section of the shaft, showed higher correlation with the one obtained by computed tomography in comparison with the conventional method. In our FCR method, moreover, interobserver reproducibility and accuracy was improved by employing automatic ...
1990-01-01
On the accuracy and effectiveness of dose reconstruction for tomotherapy
International Nuclear Information System (INIS)
Dose reconstruction is a process that re-creates the treatment-time dose deposited in a patient provided there is knowledge of the delivered energy fluence and the patient's anatomy at the time of treatment. A method for reconstructing dose is presented. The process starts with delivery verification, in which the incident energy fluence from a treatment is computed using the exit detector signal and a transfer matrix to convert the detector signal to energy fluence. With the verified energy fluence and a CT image of the patient in the treatment position, the treatment-time dose distribution is computed using any model-based algorithm such as convolution/superposition or Monte Carlo. The accuracy of dose reconstruction and the ability of the process to reveal delivery errors are presented. Regarding accuracy, a reconstructed dose distribution was compared with a measured film distribution for a simulated breast treatment carried out on a thorax ...
2001-04-01
Energy Technology Data Exchange (ETDEWEB)
This paper describes high speed rolling and gauge control in cold tandem mill for ultra-thin gauge strip at the Chiba Works of Kawasaki Steel Corporation. To improve the plate-out property of rolling oil, cationic polymeric coagulant was prepared. Rolling oil with cohesion independent of inorganic inclusions or phosphatide was developed, to improve the lubrication for cold rolling, remarkably. In addition, a low-cost Ti-enhanced work roll having high wear resistance and excellent grindability was developed. Rolling can be conducted at the optimal rolling roughness and operation can be performed at the highest rolling speed independent of the rolling treatment amount. Rolling speed at 2800 m/min was confirmed by developing the rolling oil with excellent lubrication and the work roll having high wear resistance. For the improvement of strip thickness accuracy at the steady state rolling, use of the backup ...
1996-09-01
Lymph node staging in cervical carcinoma: Results of high resolution MRT with phased-array coil
International Nuclear Information System (INIS)
Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T_2-weighted turbo-spin-echo (TSE) and T_1-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm"2. Lymph nodes with a diameter of #>=#8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes (#>=# 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of 24 cases MR findings were true negative (specificity 92%). Diagnostic accuracy was 91%. Conclusion: ...
An accurate high-speed single-electron quantum dot pump
International Nuclear Information System (INIS)
Using standard microfabrication techniques, it is now possible to construct devices that appear to reliably manipulate electrons one at a time. These devices have potential use as building blocks in quantum computing devices, or as a standard of electrical current derived only from a frequency and the fundamental charge. To date, the error rate in semiconductor 'tuneable-barrier' pump devices, those which show most promise for high-frequency operation, have not been tested in detail. We present high-accuracy measurements of the current from an etched GaAs quantum dot pump, operated at zero source-drain bias voltage with a single ac-modulated gate at 340 MHz driving the pump cycle. By comparison with a reference current derived from primary standards, we show that the electron transfer accuracy is better than 15 parts per million. High-resolution studies of the dependence of the pump current on the ...
2010-07-01
Simultaneous measurement of the neutron capture and fission yields of "2"3"3U
International Nuclear Information System (INIS)
We have measured the neutron capture and fission cross section of "2"3"3U at the neutron time-of-flight facility n-TOF at CERN in the energy range from 1 eV to 1 MeV with high accuracy by using a high performance 4#pi# BaF_2 Total Absorption Calorimeter (TAC) as a detection device. The method, based on the shape analysis of the TAC energy response, allowing to disentangle between #gamma#'s originating from fission and capture will be presented as well as the first very preliminary results. (authors)
2007-04-22
Operational Experience with LHC Collimation
A first sub-set of the collimation system has been installed for the 2008 first beam commissioning of the LHC. It included 88 collimators around the ring and the two injection lines. Each collimator has two jaws for which must be controlled and monitored with high precision. The LHC collimation system was put into operation from July to October 2008. The installed system is described and first results from system operation without and with beam are presented. It is shown that the LHC collimation system achieved the specified accuracy and reproducibility of jaw positioning. Next steps in collimation commissioning are described and planned system upgrades for high beam intensities are outlined.
2009-01-01
Grinding burn mechanism of directionally solidified superalloy
Energy Technology Data Exchange (ETDEWEB)
Directionally solidified nickel-based superalloy DZ4 is an important structural material. However, the grinding burn occurs in grinding processes has hindered the grinding efficiency and dimensional accuracy. This paper investigates the grinding mechanism of this new type of superalloy based on the systematical analyses of variable characteristics of the grinding force, grinding temperature, topography of ground surface, hardness distribution of surface layer, as well as morphology of surface layer from a metallographical point of view. The results will be beneficial to grinding the superalloy with high efficiency and high precision. (orig.)
2001-07-01
International Nuclear Information System (INIS)
The effect of a substrate on the results of measuring tantalum coating thickness in two-layer compositions according to gamma radiation scattered by the substrate is studied. It is shown that by means of an albedo-radiometer realizing the physical model absorber-scatterer one can determine the thickness (application uniformity) of tantalum coatings up to 150-300 #mu#m depending on the substrate material (plexiglas, aluminium, iron, copper). In case of testing coatings on substrates of alloys and high-alloy steels in order to ensure high accuracy of measrurement it is expedient with the above albedo-radiometer to determine the value of the backscattered radiation flux for the substrate before coating application.
High Order Finite Volume Nonlinear Schemes for the Boltzmann Transport Equation
Energy Technology Data Exchange (ETDEWEB)
The authors apply the nonlinear WENO (Weighted Essentially Nonoscillatory) scheme to the spatial discretization of the Boltzmann Transport Equation modeling linear particle transport. The method is a finite volume scheme which ensures not only conservation, but also provides for a more natural handling of boundary conditions, material properties and source terms, as well as an easier parallel implementation and post processing. It is nonlinear in the sense that the stencil depends on the solution at each time step or iteration level. By biasing the gradient calculation towards the stencil with smaller derivatives, the scheme eliminates the Gibb's phenomenon with oscillations of size O(1) and reduces them to O(h{sup r}), where h is the mesh size and r is the order of accuracy. The current implementation is three-dimensional, generalized for unequally spaced meshes, fully parallelized, and up to fifth order accurate (WENO5) in space. For unsteady problems, ...
2005-03-29
Fine-ceramic anitifriction bearings
Energy Technology Data Exchange (ETDEWEB)
Ceramic antifriction bearings were introduced in excellent characterics and application. In main shaft use bearings of the machine tool, to be heightened in efficiency and accuracy by the heightening in speed, centrifugal load to the outer ring is not negligible to shorten the bearing in life. Also ball bearings with a contact angle are easily corroded by a very strong revolution slide due to the gyromoment. The use of such light weight material as silicon nitride's can design the lengthening in life. Also the utilization of high rigidity can prevent the inner ring from expanding by centrifugal force and enable the machining to be with a high accuracy. Ceramic rolling element is excellent also in backing resistant property and effective on the oily film cut. With heat resistant property, it maintains hardness even at high temperature. Such excellent characteristics being ...
1989-08-01
Computer modeling of oil spill trajectories with a high accuracy method
Energy Technology Data Exchange (ETDEWEB)
This paper proposes a high accuracy numerical method to model oil spill trajectories using a particle-tracking algorithm. The Euler method, used to calculate oil trajectories, can give adequate solutions in most open ocean applications. However, this method may not predict accurate particle trajectories in certain highly non-uniform velocity fields near coastal zones or in river problems. Simple numerical experiments show that the Euler method may also introduce artificial numerical dispersion that could lead to overestimation of spill areas. This article proposes a fourth-order Runge-Kutta method with fourth-order velocity interpolation to calculate oil trajectories that minimise these problems. The algorithm is implemented in the OilTrack model to predict oil trajectories following the 'Nissos Amorgos' oil spill accident that occurred in the Gulf of Venezuela in 1997. Despite lack of adequate field ...
1999-07-01
Energy Technology Data Exchange (ETDEWEB)
Today`s nuclear power plants are marked by increasing needs for non-destructive inspection techniques in preventive maintenance programs. Additionally, it is becoming more important to evaluate residual stress which may be a key parameter for crack propagations in welded pipings. The authors have developed an ultrasonic velocity measurement method which obtains ultrasonic velocity changes by residual stress with a high accuracy. The ultrasonic velocity measurement is composed of three procedures. They are as follows. (1) Highly accurate propagation time measurements; (2) Pipe thickness correction; (3) Residual stress evaluation. The ultrasonic velocity measurements have been applied to the residual stress evaluation of carbon steel welded pipings. Destructive testing using stress strain gauges was done after the ultrasonic non-destructive evaluation of the residual stress. The experimental results verified that residual ...
1995-08-01
High voltage transmission lines studies with the use of artificial intelligence
Energy Technology Data Exchange (ETDEWEB)
The paper presents an alternative approach for the studies of high voltage transmission lines based on artificial intelligence and more specifically artificial neural networks (ANNs). In contrast to the existing conventional-analytical techniques and simulations which are using in the calculations empirical and/or approximating equations, this approach is based only on actual field data and actual measurements. The proposed approach is applied on high voltage transmission lines in order to calculate the lightning outages, on grounding systems in order to assess the grounding resistance and on high voltage transmission lines' polluted insulators in order to estimate the critical flashover voltage. The obtained results are very close to the actual ones for all three case studies, something which clearly implies that the ANN approach is well working and has an acceptable accuracy, constituting an ...
2009-12-15
International Nuclear Information System (INIS)
The "2"3"3U(n,f) cross section has been measured at the white neutron source n_TOF in a wide energy range with a dedicated fission ionization chamber. We report here the results from #approx#30 meV to 1 MeV neutron energy. The "2"3"3U(n,f) cross section has been determined relative to a reference sample of "2"3"5U(n,f) measured simultaneously with the same detector. The very high instantaneous neutron flux and the intrinsically low background of the n_TOF installation result in an accuracy around 3% in the whole energy range, while the energy resolution of the neutron beam allows for an accurate description of the fission cross section by means of R-matrix analysis over a wide energy range. The results are, in general, in good agreement with the most recent high-accuracy measurement of this fission cross section, over the more limited range of the previous measurements, and indicated that even the latest evaluations ...
2009-10-01
Forecasting for utility-scale wind farms. The power model challenge
Energy Technology Data Exchange (ETDEWEB)
As the penetration of wind energy continues to increase around the world, with a trend towards large utility-scale wind farms (greater than 100 MW), effective wind energy forecasting will become increasingly important. Previous work by GH has estimated the trading benefit of high quality short-term forecasting to be EUR 7/MWh. Depending on market conditions, for a 100 MW wind farm with a capacity factor of 30%, this equates to an estimated annual trading benefit of up to EUR 1.8m. To date, a number of studies have focused on the mathematical modelling techniques for forecasting the production from wind farms, looking predominantly at the task of predicting the meteorological conditions at the site. This paper focuses on the final stage of the forecasting process, conversion from a meteorological forecast to a power production forecast. This challenge is particularly significant for utility-scale wind farms. The main body of research in short-term forecasting in ...
2008-07-01
Design of the ZTH vacuum liner
Energy Technology Data Exchange (ETDEWEB)
The current status of the ZTH vacuum liner design is covered by this report. ZTH will be the first experiment to be installed in the CPRF (Confinement Physics Research Facility) at the Los Alamos National Laboratory and is scheduled to be operational at the rated current of 4 MA in 1992. The vacuum vessel has a 2.4 m major radius and a 40 cm minor radius. Operating parameters which drive the vacuum vessel mechanical design include a 300 C bakeout temperature, an armour support system capable of withstanding 25 kV, a high toroidal resistance, 1250 kPa magnetic loading, a 10 minute cycle time, and high positional accuracy with respect to the conducting shell. The vacuum vessel design features which satisfy the operating parameters are defined. The liner is constructed of Inconel 625 and has a geometry which alternates sections of thin walled bellows with rigid ribs. These composite sections span between pairs of the 16 ...
1987-01-01
International Nuclear Information System (INIS)
This paper discusses essentially the role of WDXRFS based multi element data in uranium exploration, with special reference to India. The state of art MagiX-PRO WDXRFS with 4 kW end window x-ray tubes has been used in the present study as an indispensable geo-analytical tool for the analysis of major and selected trace elements at ppm to percentage level, with high precision and relatively better accuracy
2010-10-01
Energy Technology Data Exchange (ETDEWEB)
This report details an investigation into the efficacy of two approaches to solving the radiation diffusion equation within a radiation hydrodynamic simulation. Because leading-edge scientific computing platforms have evolved from large single-node vector processors to parallel aggregates containing tens to thousands of individual CPU's, the ability of an algorithm to maintain high compute efficiency when distributed over a large array of nodes is critically important. The viability of an algorithm thus hinges upon the tripartite question of numerical accuracy, total time to solution, and parallel efficiency.
1999-10-28
Radon measurements in dwellings using activated charcoal
Energy Technology Data Exchange (ETDEWEB)
In Sweden there is a demand for a method of measuring radon in dwellings with high accuracy and at a low cost. A method of determining radon concentration (Bq.m/sup -3/) in dwellings has been developed at the Swedish National Testing Institute. A plastic canister containing activated charcoal has been tested in a radon chamber (volume 20 m/sup 3/) to determine the effects of relative humidity, temperature and exposure time. The activated charcoal in the canister adsorbs radon from the air surrounding the canister. The radon concentration is determined by counting the gamma rays from the decay of radon and daughters. The theory and preliminary results from calibrations and field measurements are reported.
1984-01-01
Outage Probability of Diversity Combining Receivers in Arbitrarily Fading Channels
We propose a simple and accurate method to evaluate the outage probability at the output of arbitrarily fading L-branch diversity combining receiver. The method is based on the saddlepoint approximation, which only requires the knowledge of the moment generating functions of the signal-to-noise ratio at the output of each diversity branch. In addition, we show that the obtained results reduce to closed-form expressions in many particular cases of practical interest. Numerical results illustrate a very high accuracy of the proposed method for practical outage values and for a large mixture of fading and system parameters.
2011-01-01
New techniques for electron-ion collision studies
International Nuclear Information System (INIS)
We have constructed an apparatus to study electron impact ionization of ions which should provide additional insight into the mechanisms involved. Using multiparameter coincidence techniques, we will detect both outgoing electrons from ionization process and will be able to analyze the momenta of both particles simultaneously. Coupled with a high resolution electron gun, this information should have broad application to the difficult problem of three bodies interacting via the long range Coulomb force. If sufficient accuracy can be achieved, information regarding the relative phase of the outgoing electron wavefunctions can be obtained.
Fiber optic quality assurance at the Nevada Test Site
Energy Technology Data Exchange (ETDEWEB)
A large number of fiber optic cables were used in support of a neutron imaging experiment at the Nevada Test Site. This paper describes the quality control testing of fiber components used on this experiment. The principal reason for quality control testing was to ensure reliable, high transmission fibers; a secondary reason was to gain data on a large sample of fiber cables in the field. Also described is the instrumentation developed for carrying out these field measurements. The design of the quality control instrumentation was a compromise between accuracy and simplicity of use.
1981-01-01
International Nuclear Information System (INIS)
Three cases of primitive suprasellar germinomas are reported: the tumors show typical clinical signs (diabetes insipidus, disfunctions), but CT findings are not so specific. It is very important to reach a correct diagnosis based on clinical and radiological findings, because of very high radiosensibility of the tumor. The accuracy of preoparative diagnosis has been enhanced by CT in addition to conventional neuroradiological examinations. Due to the possible risk of meningeal spreading following biopsy, some authors prefer to avoid biopsy and to treat directly the patient by radiotherapy; a rapid reduction of the tumor size at the dose of 30 Gy suggest a possible germinoma.
1986-01-01
System identification is a necessity in control theory. Classical control theory usually considers processes with integer order transfer functions. Real processes are usually of fractional order as opposed to the ideal integral order models. A simple and elegant scheme is presented for approximation of such a real world fractional order process by an ideal integral order model. A population of integral order process models is generated and updated by PSO technique, the fitness function being the sum of squared deviations from the set of observations obtained from the actual fractional order process. Results show that the proposed scheme offers a high degree of accuracy.
2008-01-01
A dose computation algorithm used in MLC conformal treatment
International Nuclear Information System (INIS)
A dose calculation algorithm for MLC based conformal radiotherapy is described in this paper. The algorithm is formulated by the coordinate of MLC leaves. Verification on the algorithm is made by comparing the dose distributions generated by this algorithm with that generated by a Differential Convolution Superposition algorithm for various regular and irregular fields. The results demonstrate that the present algorithm has suitable accuracy and high computational efficiency, thus it could be useful for the treatment planning process in MLC based conformal radiotherapy, where the workload for interactively or automatically designing the shapes of MLC is heavy. (authors)
2007-12-01
Neutron cross-sections for next generation reactors: New data from n_TOF
International Nuclear Information System (INIS)
In 2002, an innovative neutron time-of-flight facility started operation at CERN: n_TOF. The main characteristics that make the new facility unique are the high instantaneous neutron flux, high resolution and wide energy range. Combined with state-of-the-art detectors and data acquisition system, these features have allowed to collect high accuracy neutron cross-section data on a variety of isotopes, many of which radioactive, of interest for Nuclear Astrophysics and for applications to advanced reactor technologies. A review of the most important results on capture and fission reactions obtained so far at n_TOF is presented, together with plans for new measurements related to nuclear industry.
2008-06-22
International Nuclear Information System (INIS)
Cavity ringdown spectroscopy (CRDS) with continuous-wave (cw) laser excitation has added high frequency resolution to the ability of CRDS being used for the absolute quantification of trace-level species present in many chemical processes. Cavity dithering technique has easily resolved the problem of resonant coupling of a cw laser light into a high-finesse cavity. The present study addresses the potential uncertainty involved in such cw-CRDS techniques incorporating the cavity mirror motion, i.e., the doppler frequency shift of a probe light inside the cavity. In the high-resolution spectroscopic work of megahertz-accuracy, even the influence of intracavity doppler effect may become significant.
2001-11-01
British Library Electronic Table of Contents (United Kingdom)
To form a licensing basis for a new methodology for a fuel channel safety analysis code for CANDU-6 nuclear reactor, a CATHENA model for a post-blowdown fuel channel analysis has been developed, and tested for a high temperature thermal-chemical experiment CS28-1 [Lei, Q.M., 1993. Post-test analysis of the 28-element high-temperature thermal-chemical experiment CS28-1. In: 4th International Conference on Simulation Methods in Nuclear Engineering, Montreal, PQ, 1993]. Pursuant to the objective of this investigation, the current study has focused on understanding the involved phenomena, their interrelations, and how to maintain a good accuracy of the temperature and H2 generation rate prediction without losing the important physics of the involved phenomena. The transient simulation results ...
2009-01-01
International Nuclear Information System (INIS)
Alexandria is the second largest urban governorate in Egypt and has seen significant urban growth in its modern and contemporary history. This study investigates the urban growth phenomenon in Alexandria, Egypt, using the integration of remote sensing and GIS. The urban physical expansion and change were detected using Landsat satellite images. The satellite images of years 1984 and 1993 were first geo referenced, achieving a very small RMSE that provided high accuracy data for satellite image analysis. Then, the images were classified using a tailored classification scheme with accuracy of 93.82% and 95.27% for 1984 and 1993 images respectively. This high accuracy enabled detecting land use/land cover changes with high confidence using a post-classification comparison method. One of the most important findings here is the loss of cultivated land in favour of ...
Methods and results for calibration and track separation of a GEM based TPC using an UV-laser
Energy Technology Data Exchange (ETDEWEB)
In the last 30 years high energy physics could write an impressive story of success. Since the introduction of the Standard Model (SM), it has met every experimental test. However the final confirmation has to prove the mechanism of electroweak symmetry breaking, which could not be confirmed yet. The most favored theory, which includes the introduction of a Higgs field, could not be verified experimentally. Furthermore there is clear evidence, that the SM is only a low energy description of nature and its principles, as the SM describes only 4 % of the known matter in the universe. There are two different approaches in accelerator driven high energy physics to clarify the open questions. The Large Hadron Collider (LHC) have a good opportunity to measure some of the missing pieces with its high center of mass energy. The International Linear Collider (ILC) will then measure their parameters with high ...
2008-12-15
Nuclear charge radii of light isotopes based on frequency comb measurements
Energy Technology Data Exchange (ETDEWEB)
Optical frequency comb technology has been used in this work for the first time to investigate the nuclear structure of light radioactive isotopes. Therefore, three laser systems were stabilized with different techniques to accurately known optical frequencies and used in two specialized experiments. Absolute transition frequency measurements of lithium and beryllium isotopes were performed with accuracy on the order of 10{sup -10}. Such a high accuracy is required for the light elements since the nuclear volume effect has only a 10{sup -9} contribution to the total transition frequency. For beryllium, the isotope shift was determined with an accuracy that is sufficient to extract information about the proton distribution inside the nucleus. A Doppler-free two-photon spectroscopy on the stable lithium isotopes {sup 6,7}Li was performed in order to determine the absolute frequency of the 2S {yields} 3S ...
2010-02-11
The models of experimental magnetic measurements of various biological samples
International Nuclear Information System (INIS)
Complete text of publication follows. At the Geomagnetic Institute, in the Laboratory for paleomagnetism and archeomagnetism research and at the Geomagnetic Observatory, Grocka (GCK) during the period from November 2004 to February 2008 the researchers carried out experimental magnetic measurements of the total-intensity gradient of the magnetic field vector (changes in the total magnetisation vector) of various biomaterials. Measurements of the gradient total intensity of the magnetic field vector were carried out by GSM-19 magnetometers of high accuracy and recording resolution (accuracy: #DELTA#F=0.1 nT; sampling rate: 1-5 per second). During these experimental biomagnetic measurements samples of water, tissue, blood, cotton, wool, pitch and magnetite-powder were used. In this study, the part of the biomagnetic measurement results relate to the water, blood and tissue. The results of the measurements of gradient ...
2009-08-23
Energy Technology Data Exchange (ETDEWEB)
E-35 reported the specific air flow analysis program using a CFSV model (including a human body model) to develop a high-accuracy evaluation simulator for heterogeneous thermal environment based on human thermal physiological conditions. E-36 reported development of the radiation heat transfer analysis module by using a numerical integral method to calculate shape factors. Radiation heat transfer characteristics every body part were clarified quantitatively by this module. E-37 reported the results on continuous measurement of physiological conditions and thermal environment factors every monitor under controlled indoor thermal environment, to collect measurement data necessary for improving the accuracy of a prediction program for human body temperatures. E-38 reported the study result on physiological reaction and subjective evaluation through an examinee experiment in a blood controlled region, to collect basic data for the above ...
1999-12-05
Development of a fine and ultra-fine group cell calculation code SLAROM-UF for fast reactor analyses
International Nuclear Information System (INIS)
A cell calculation code SLAROM-UF has been developed for fast reactor analyses to produce effective cross sections with high accuracy in practical computing time, taking full advantage of fine and ultra-fine group calculation schemes. The fine group calculation covers the whole energy range in a maximum of 900-group structure. The structure is finer above 52.5 keV with a minimum lethargy width of 0.008. The ultra-fine group calculation solves the slowing down equation below 52.5 keV to treat resonance structures directly and precisely including resonance interference effects. Effective cross sections obtained in the two calculations are combined to produce effective cross sections over the entire energy range. Calculation accuracy and improvements from conventional 70-group cell calculation results were investigated through comparisons with reference values obtained with continuous energy Monte Carlo calculations. It was ...
2006-08-01
Energy Technology Data Exchange (ETDEWEB)
To determine clinical predictors and accuracy of {sup 123}I-FP-CIT SPECT imaging in the differentiation of drug-induced parkinsonism (DIP) and Parkinson's disease (PD). Several clinical features and {sup 123}I-FP-CIT SPECT images in 32 patients with DIP, 25 patients with PD unmasked by antidopaminergic drugs (PDu) and 22 patients with PD without a previous history of antidopaminergic treatment (PDc) were retrospectively evaluated. DIP and PD shared all clinical features except symmetry of parkinsonian signs which was more frequently observed in patients with DIP (46.9%) than in patients with PDu (16.0%, p<0.05) or PDc (4.5%, p<0.01). Qualitatively {sup 123}I-FP-CIT SPECT images were normal in 29 patients with DIP (90.6%) and abnormal in all patients with PD, and this imaging technique showed high levels of accuracy. DIP and PD are difficult to differentiate based on clinical signs. The precision of ...
2010-03-15
Adaptive and mobile ground sensor array.
Energy Technology Data Exchange (ETDEWEB)
The goal of this LDRD was to demonstrate the use of robotic vehicles for deploying and autonomously reconfiguring seismic and acoustic sensor arrays with high (centimeter) accuracy to obtain enhancement of our capability to locate and characterize remote targets. The capability to accurately place sensors and then retrieve and reconfigure them allows sensors to be placed in phased arrays in an initial monitoring configuration and then to be reconfigured in an array tuned to the specific frequencies and directions of the selected target. This report reviews the findings and accomplishments achieved during this three-year project. This project successfully demonstrated autonomous deployment and retrieval of a payload package with an accuracy of a few centimeters using differential global positioning system (GPS) signals. It developed an autonomous, multisensor, temporally aligned, radio-frequency communication and signal ...
2003-12-01
TEST PLANNING APPROACH AND LESSONS. - NASA Technical Report Server ...
requirements) + f3(accuracy of analyses) + f4(accuracy of fabrication) + f5( design time) + .... Learning curves suggest an evolution in rocket engines& ...
Energy Technology Data Exchange (ETDEWEB)
A method of abrasion testing according to ASTM C 704-76 a is presented for steel fibre concrete mortar, fusion-cast basalt and a surface coating material and results of practical interest are mentioned. Due to the high technical demands on these materials and their specific fields of application, the very first test already supplied interesting findings. From the user's point of view, the method is an interesting alternative to the common test methods, e.g. according to DIN 52 108 (wheel test according to Boehme). In English-speaking countries, testing according to ASTM is often mandatory in the refractory industry in order to assure constant quality of refractory materials after setting. The method is characterized by good comparability and high accuracy of measurement. Only the test piece is exchanged while the test conditions remain constant, so that accurate information on the material studied is obtained.
1983-06-01
PVT-apparatus for measurements on gas/oil solutions up to 2000 bar and 440 K
Energy Technology Data Exchange (ETDEWEB)
A high pressure piezometer is described with which pVT-measurements on solutions of gases in liquids like oils can be performed at pressures and temperatures up to 2000 bar and 440 K, respectively. The present investigations deal mainly with the system squalaneCO/sub 2/ at different mole fractions, but also with squalaneN/sub 2/. The high accuracy of the measurements reveals a pronounced structure of the pV-curves in dependence on temperature and mole fraction. At larger mole fractions is the unequivocal assignment of the phases ambiguous, and the representation of the experimental data in terms of an equation of state not possible for the whole pressure and temperature range. However, for solutions with lower mole fractions could be determined the saturation pressures and the isothermal compressibility in the unsaturated region. Furthermore, the molar excess volumes of the mixture have been calculated and the phase ...
1982-11-01
Materials Research Related to W-band Cavity Construction
Energy Technology Data Exchange (ETDEWEB)
Low power rf measurements, S11, of electro-discharge machined (EDM) diffusion bonded mm-wave traveling wave rf cavities were not in satisfactory agreement with electromagnetic simulations. During subsequent mechanical inspection, the cell-to-cell iris were found to be distorted. This led to a series of systematic experiments to study the mechanical properties of oxygen free high conductivity Copper (OFHC) and Glidcop AL-15. Results of these studies which include cell-to-cell iris distortion, EDM machining accuracies, surface quality, and the results of different bonding techniques are presented. The results of our mechanical studies are used to develop a set of mechanical design constraints for a second series of constant impedance W-Band structures that also used wire EDM and high temperature bonding for their manufacture.
2000-10-18
Fluid temperature measurement technique by using Raman scattering
Energy Technology Data Exchange (ETDEWEB)
Temperature measurement technique by using Raman scattering was developed for the liquid water at temperature of 20 - 90 degree C and atmospheric pressure. Strong relationship between Raman scattering characteristics and liquid temperature change was observed. Various kinds of measurement techniques, such as Peak Intensity, Peak Wavelength, FWHM (Full Width at Half Maximum), PMCR ( Polymer Monomer Concentration RAte), TSIR (Temperature Sensitive Intensity Ratio), IDIA (Integral Difference Intensity Area) were tested. TSIR has the highest accuracy in mean error or 0.1 deg C and standard deviation of 0.1248 deg C. This report is one of the results in developing process of Raman temperature measurement technique. Next research step is to develop Raman temperature measurement technique at the high temperature and high pressure conditions in single or two phase flows. (author). 13 refs., 3 tabs., 38 figs.
1999-06-01
Fetal MRI of pathological brain development
International Nuclear Information System (INIS)
Because of the superior tissue contrast, high spatial resolution, and multiplanar capabilities, fetal magnetic resonance imaging (MRI) can depict fetal brain pathologies with high accuracy. Pathological fetal brain development may result from malformations or acquired conditions. Differentiation of these etiologies is important with respect to managing the actual pregnancy or counseling future pregnancies. As a widened ventricular system is a common hallmark of both maldevelopment and acquired conditions, it may cause problems in the differential diagnosis. Fetal MRI can provide detailed morphological information, which allows refinement of the diagnosis of ventricular enlargement in a large number of cases. Systematic work-up of morphological details that may be recognized on MR images provides an approach for achieving a correct diagnosis in cases of ventricle enlargement. (orig.)
2006-02-01
The economic benefits of supplemental fuel injections depend, in part, on the coke replacement ratio. An assessment of the accuracy with which blast furnace coke rate may be measured and a determination of the key drivers of coke rate uncertainty are offered, to provide guidance for experiments in high-rate gas injection. Using statistical analysis tools, an expression for the measurement error associated with the various terms of blast furnace carbon balance is developed. Coke rate calculations based on the material balance are most sensitive to coke carbon content and to proper tracking of hot metal tapping schedule.
1992-09-01
Clustering high dimensional data using subspace and projected clustering algorithms
Problem statement: Clustering has a number of techniques that have been developed in statistics, pattern recognition, data mining, and other fields. Subspace clustering enumerates clusters of objects in all subspaces of a dataset. It tends to produce many over lapping clusters. Approach: Subspace clustering and projected clustering are research areas for clustering in high dimensional spaces. In this research we experiment three clustering oriented algorithms, PROCLUS, P3C and STATPC. Results: In general, PROCLUS performs better in terms of time of calculation and produced the least number of un-clustered data while STATPC outperforms PROCLUS and P3C in the accuracy of both cluster points and relevant attributes found. Conclusions/Recommendations: In this study, we analyze in detail the properties of different data clustering method.
2010-01-01
A combined interpretation of cosmic ray and antiproton high energy measurements
Energy Technology Data Exchange (ETDEWEB)
In the last months several ballon and satellite experiments improved significantly our knowledge of cosmic ray (CR) spectra at high energy. In particular CREAM allowed to measure B/C, C/O and N/O ratios up to 1 TeV/n and PAMELA the anti p/p ratio up to 100 GeV with unprecedented accuracy. These measurements offer a valuable probe of CR propagation properties. We performed a statistical analysis to test the compatibility of these results, as well as other most significant experimental data, with the predictions of a new numerical CR diffusion package (DRAGON). We found that above 1 GeV/n all data are consistent with a plain diffusion scenario and point to well defined ranges for the normalization and energy dependence of the diffusion coefficient. (orig.)
2009-09-15
Energy Technology Data Exchange (ETDEWEB)
The use of the focused ion beam (FIB) systems has increased to a high level in recent years. The imaging, milling, and deposition capabilities of the FIB make it the ideal instrument for e.g., site-specific failure analysis, specimen preparation and nano-machining. Ion channelling contrast allows for selective imaging of polycrystalline and polyphase microstructures. In addition, the FIB and CrossBeam registered instruments are unique stand-alone analytical tools. Their vast capabilities have enabled numerous applications into the semiconductor and materials sciences applications. These integrated CrossBeam registered Tools enable the observation and direct control of the FIB operation in real time. In addition to the improved accuracy and resolution the electron beam adds analytical capabilities as STEM, EDS and EBSP to the instruments. To ensure a safe and reliable operation of the instrument, a dedicated vacuum system is needed. This type of ...
2005-07-01
Development of in-vessel type control rod drive mechanism for marine reactor
Energy Technology Data Exchange (ETDEWEB)
A highly reliable control rod drive mechanism (CRDM) installed inside the reactor vessel has developed for use of an advanced marine reactor. This CRDM contributes to compactness and simplicity of the reactor system, and it can eliminate the possibility of a rod ejection accident. The CRDM works in the high temperature and high pressure water - 310degC and 12 MPa, the same atmosphere as the primary loop. Driving force is produced by a synchronous motor with the rotor of a permanent magnet, which has been developed. An innovative latch mechanism using separable ball nuts can latch driving shaft connecting the control rod and de-latch it for scram. The rod position detector using a magnetostrictive wire type sensor on the principle of Wiedeman effect has been developed, accuracy of which is verified to have a detecting error within 1.2 mm. Ball bearings for thrust and radial supports in rotation have been ...
2001-07-01
Energy Technology Data Exchange (ETDEWEB)
The design of separation devices, particularly for solvent-based selective removal of H{sub 2}S from CO{sub 2}, requires an accurate mathematical model. Unfortunately, this requirement for high accuracy is often in conflict with the need for efficient computation. The addition of more and more complicated analyses, such as a move from Henry's law to a method incorporating gas and liquid activities for computing vapor liquid equilibria, may give a more accurate solution, but only at the cost of decreased computational efficiency. The efforts in this work have been directed toward two goals. The first was to develop an accurate mathematical model for the aqueous methyldiethanolamine (MDEA) system. The steady-state packed column model developed in this work has been tested with data from Schubert (1988) to verify its accuracy. The second goal was to modify the model to improve its computational efficiency. Areas such ...
1988-01-01
Computerized Tomography-guided fine-needle biopsy of peripheral pulmonary nodules < 2 cm in diameter
International Nuclear Information System (INIS)
The authors investigated the role of Computerized Tomography in guiding fine needle biopsy (FNB) in small (2 2 cm in diameter for CT-guided FNB sensitivity, specificity and diagnostic accuracy. Cytologic specimens were positive for malignancy in 40/52 cases (76.9%) and negative in 12 (23.1%). Clinical-surgical follow-up confirmed all the positive cytologic findings (40 cases), while 2 of the extant 12 cases were false negatives (95.20% sensitivity, 100% specificity and 96.15% diagnostic accuracy). 158 of 195 nodules > 2 cm in diameter and with clinical surgical follow-up (81.3%) were positive for malignancy and 34 were negative (17.43%) (98.75% sensitivity, 97.14% specificity and 98.46% diagnostic accuracy). Pneumothorax occurred in 33 patients (16.5%) with nodules > 2 cm in diameter as a complication of biopsy. Hemoptysis occurred in 15 patients (7.5%). In the whole group of lung lesions, the complications were ...
International Nuclear Information System (INIS)
Objective was to assess the accuracy of a single versus combined use of ultrasound (US) or computed tomography (CT) in the localization of diseased parathyroid glands. Forty-one patients with hyper-parathyroidism treated surgically between January 2000 to December 2005 at Jordan University Hospital, Amman, Jordan were included in this study. Preoperative ultrasonographic and CT findings were reviewed and compared to the intraoperative and pathologic diagnosis of diseased parathyroid glands. The mean age of patients was 46 years (range 16-70; 15 males and 26 females). Parathyroid adenoma was confirmed in 33 patients and hyperplasia of the parathyroid glands in 8 patients. Preoperative evaluation was carried out in 32 patients (CT scan) and in 23 patients (US). In 18 cases, the diagnosis of parathyroid disease was based on CT findings alone and in 9 patients the diagnosis was based on a single US finding. Combined CT and US evaluation was carried out in 14 cases and ...
"Hyperfine Splitting, Isotope Shift, and Level Energy of the 3S States of Li-6, Li-7."
Energy Technology Data Exchange (ETDEWEB)
High-precision laser spectroscopy on lithium isotopes is of fundamental interest, experimentally as well as theoretically. The lithium atom has long served as a test system for the calculation of various atomic properties in few-electron atoms and significant advances have been made in the last decade[1-3]. Recently, calculations of transition energies for the 22S1/2 -> 32S1/2 and the 22S1/2 -> 22P1/2, 3/2 transitions and of the mass-dependant isotope shift (IS) in these transitions have been reported with a relative accuracy of better than 1 X 10-7 and 5 x 10-6, respectively[4, 5]. These calculations are the foundation for experimental efforts, currently underway at GSI Darmstadt, Germany, to determine the root-mean-square (rms) charge radius of the unstable lithium isotopes[6, 7]. The basic principle is that if all mass-dependent contributions to the IS can be calculated with sufficient accuracy, the ...
2003-07-25
Energy Technology Data Exchange (ETDEWEB)
This paper introduces a multichannel digital data acquisition system and examples of measurements with the system in seismic exploration using the high resolution seismic refraction method. The high resolution seismic refraction system performs analyses nearly automatically by using a computer after initial travel time has been read. Therefore, the system requires high-accuracy travel time data, for which a multichannel digital measuring instrument developed recently for seismic exploration using the refraction method has been used for the measurement. The specification specifies the number of channels at 144 as a maximum, a sampling time of 62.5 {mu}sec to 4 m sec, the maximum number of sampling of 80,000 samples, and gain accuracy of {plus_minus} 1%. The system was used for surveying a tunnel having a maximum soil cover of about 800 m. The traverse line length is about 6 km, the distance between ...
1997-05-27
A computer was built for use with the NRU reactor to solve the problem of Xe/sup 135/ concentrations. The effect of any changes in reactor on Xe/sup 135/ concentration can be predicted and steps taken to avoid poisoning out. An electromechanical system was used for the computer to avoid the inherent disadvantages that electronic analog computers present for problems of very long solution times. The electromechanical analog computer has a high order of reliability and contains no vaccum tubes, commutators, slip rings, relays, or aluminum electrolytic capacitors. It is insensitive to transient disturbarce. In the event of failure of components or interruption of line voltage, it will retain existing information. The computer was designed for ~ 1% accuracy in Xe/ sup 135/ concentration readings. (W.D.M.)
1958-05-01
British Library Electronic Table of Contents (United Kingdom)
Coal exploitation inevitably damages the natural ecological environment through large scale underground exploitation which exhausts the surrounding areas and is the cause of surface subsidence and cracks. These types of damage seriously lower the underground water table. Deterioration of the environment has certainly an impact on and limits growth of vegetation, which is a very important indicator of a healthy ecological system. Dynamically monitoring vegetation growth under coal exploitation stress by remote sensing technology provides advantages such as large scale coverage, high accuracy and abundant information. A scatter plot was built by a TM (Thematic Mapper) infrared and red bands. A detailed analysis of the distributional characteristics of vegetation pixels has been carried out. ...
2007-01-01
Use of a novel acoustic dissolved oxygen transmitter for fish telemetry
DEFF Research Database (Denmark)
The multiple responses of fishes to changes in dissolved oxygen saturations have been studied widely in the laboratory. In contrast only few studies have included field observations. The objective of the present study was to evaluate the performance of a novel acoustic dissolved oxygen transmitter for field biotelemetry. The results demonstrated that the output of the transmitter was unaffected by three different temperatures (10 to 30 degrees C) and described the dissolved oxygen saturation with high accuracy (r(2) > 0.99) over the entire range of 0 to 191% saturation. The response time (>= 90% of end value) of the transmitter was 12 s both in terms of decreasing (100 to 0%) and increasing (0 to 100%) oxygen saturations. When externally attached to fishes the present findings support the use of the transmitter for reliable dissolved oxygen measurements on individuals living in environments that may change both temporally and spatially ...
2006-01-01
Tunable single-wavelength semiconductor lasers
Energy Technology Data Exchange (ETDEWEB)
This dissertation deals with both the theoretical and the technological aspects of monolithic tunable lasers, and the experimental techniques for opto-electronic integration. In the theoretical part, the principles and limitations of wavelength tuning and spectral linewidth reduction in monolithic semiconductor lasers are described, with coupled distributed feedback-Fabry Perot (DFB-FP) lasers and long DFB lasers as examples. Stepwise tuning of wavelength over tens of nanometers and continuous tuning over the range of a mode spacing are shown to be possible. Spatial hole burning is found to affect the spectral linewidth of lasers involving strong active gratings. On the technological side, one of the major issues is the fabrication of flexible gratings. Direct-writing techniques, such as focused ion beam (FIB) implantation and e-beam lithography, provide the resolution, flexibility and accuracy that conventional holographic lithography lacks. The parasitic ...
1988-01-01
Some sensitivities during a LWR severe core-damage sequence
International Nuclear Information System (INIS)
Stable boiloff of core water during a severe LWR accident, that is, boiloff driven only by the decay power generated below the water level, is tractable analytically and is relatively insensitive to axial power distribution. As might be expected, calculated accident event times are sensitive to the fidelity of the decay power model. During later stages of boiloff, heat transfer or transport of energy from above the water level to the residual water can result in an unstable condition during which the boiloff rate increases greatly. The unstable boiloff phenomenon illustrates the highly nonlinear influence of core heat transfer during meltdown and emphasizes the great accuracy requirements which attend the modeling of the accident during periods of enhanced heat transfer when significant zirconium oxidation is possible.
1981-12-04
Simulation of the New York Power Pool for dispatcher training
This paper describes the simulation of the operating environment of the New York Power Pool (NYPP) within the Dispatcher Training Simulator facility at the New York State Electric and Gas Corporation (NYSEG). The NYSEG control center uses real-time data received from the NYPP control center to control its internal generation. In addition, the NYSEG dispatchers work very closely with the NYPP dispatchers. The exact emulation of the Generation Control functions of the NYPP EMS, and the associated data exchange with the NYSEG ECS, contribute greatly to the high degree of realism achieved in the NYSEG DTS facility. The accuracy of the power system simulation in the DTS has been validated against actual power system disturbances recorded at NYSEG.
1994-11-01
Semantic annotation of biosystematics literature without training examples
British Library Electronic Table of Contents (United Kingdom)
This article presents an unsupervised algorithm for semantic annotation of morphological descriptions of whole organisms. The algorithm is able to annotate plain text descriptions with high accuracy at the clause level by exploiting the corpus itself. In other words, the algorithm does not need lexicons, syntactic parsers, training examples, or annotation templates. The evaluation on two real-life description collections in botany and paleontology shows that the algorithm has the following desirable features: (a) reduces/eliminates manual labor required to compile dictionaries and prepare source documents; (b) improves annotation coverage: the algorithm annotates what appears in documents and is not limited by predefined and often incomplete templates; (c) learns clean and reusable concept...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
A back-propagation neural network technique is used at JET to extract plasma parameters like ion temperature, rotation velocities or spectral line intensities from charge exchange (CX) spectra. It is shown that in the case of the C VI CX spectra, neural networks can give a good estimation (better than +-20% accuracy) for the main plasma parameters (Ti, V{sub rot}). Since the neural network approach involves no iterations or initial guesses the speed with which a spectrum is processed is so high (0.2 ms/spectrum) that real time analysis will be achieved in the near future. 4 refs., 8 figs.
1994-07-01
New Measurements of the Proton Electromagnetic Form Factor Ratio at Low Q{sup 2}
Energy Technology Data Exchange (ETDEWEB)
Polarization measurements are allowing the electric to magnetic form factor ratio of the proton to be determined with unprecedented precision. Recent results indicate that there is a large deviation from unity in the proton form factor ratio around Q{sup 2}{approx_equal}0.35 GeV{sup 2}. Furthermore, the deviation from unity is attributed to a deviation of the electric form factor from standard fits and calculations. A new, partially completed, experiment will significantly improve the existing data and will determine the presence, if any, of a narrow structure in the form factor ratio. The new measurement, combined with the expected high precision cross section measurements, will allow the extraction of individual form factors with unprecedented accuracy at low Q{sup 2}.
2009-08-15
Laser-assisted asymmetric incremental sheet forming of titanium sheet metal parts
British Library Electronic Table of Contents (United Kingdom)
Asymmetric Incremental Sheet Forming (AISF) is a relatively new manufacturing process. In AISF, a CNC driven forming tool imposes a localized plastic deformation as it moves along the contour of the desired part. Thus, the final shape is obtained by a sequence of localized plastic deformations. AISF is suitable for small series production of sheet metal parts as needed in aeronautical and medical applications. Two main process limits restrict the range of application of AISF in these fields. These are the low geometrical accuracy of parts made from titanium alloys or high strength steels and, for titanium alloys, the limited formability at room temperature. In this paper a new concept for laser-assisted AISF is introduced including the required components. Furthermore, the CAX tools used f...
2011-01-01
Improvements on burnup chain model and group cross section library in the SRAC system
Energy Technology Data Exchange (ETDEWEB)
Data and functions of the cell burnup calculation of the SRAC system were revised to improve mainly the accuracy of the burnup calculation of high conversion light water reactors (HCLWRs). New burnup chain models were developed in order to treat fission products (FPs) and actinide nuclides in detail. Group cross section library, SRACLIB-JENDL2, was generated based on JENDL-2 nuclear data file. In generating this library, emphasis was placed on FPs and actinides. Also revised were the data such as the average energy release per fission for various actinides. These improved data were verified by performing the burnup analysis of PWR spent fuels. Some new functions were added to the SRAC system for the convenience to yield macroscopic cross sections used in the core burnup process. (author).
1992-01-01
International Nuclear Information System (INIS)
There is currently great interest in combining focused ion beam (FIB) and scanning electron microscopy technologies for advanced studies of polymeric materials and biological microstructures, as well as for sophisticated nanoscale fabrication and prototyping. Irradiation of electrically insulating materials with a positive ion beam in high vacuum can lead to the accumulation of charge, causing deflection of the ion beam. The resultant image drift has significant consequences upon the accuracy and quality of FIB milling, imaging and chemical vapour deposition. A method is described for suppressing ion beam drift using a defocused, low-energy primary electron beam, leading to the derivation of a mathematical expression to correlate the ion and electron beam energies and currents with other parameters required for electrically stabilizing these challenging materials.
2007-02-07
Finite element analysis of a scanning x-ray microscope micropositioning stage
Energy Technology Data Exchange (ETDEWEB)
A micropositioning stage for use with an x-ray microscope has been developed to scan samples over a 100 {mu}m{times}100-{mu}m area with a resolution of 100 A. The stage employs flexure hinges driven by piezoelectric actuators to achieve this high positioning accuracy. Due to the severe geometry of the hinges, stresses and deflections are determined (via finite element methods) to ensure a credible design. Since the stage is to be used in a stepping capacity, natural frequencies are computed to identify resonant conditions which could potentially cause excessive deflections. The finite element models show that the stage responds like a discrete lumped-mass system for the lower modes, and a continuous system with flexural characteristics for the higher modes.
1992-01-01
Energy Technology Data Exchange (ETDEWEB)
A data analysis based on an artificial neural network classifier is proposed to identify cosmic ray antiprotons detected with the CAPRICE silicon-tungsten imaging calorimeter against electron background in the energy range 1.2-4.0 GeV. A set of new physical variables, describing the events inside the calorimeter on the base of their different patterns, are introduced in order to discriminate between hadronic and electromagnetic showers. The ability of the artificial neural network classifier to perform a careful multidimensional analysis gives the possibility to identify antiprotons with an electron rejection 408{+-}85 (stat) at 95.0{+-}0.2 (stat)% of signal detection efficiency. The high accuracy achieved by this method improves substantially the efficiency in the evaluation of the cosmic ray antiproton spectrum. (orig.).
1996-11-01
Combined migration velocity model-building and its application in tunnel seismic prediction
We propose a combined migration velocity analysis and imaging method based on Kirchhoff integral migration and reverse time migration, using the residual curvature analysis and layer stripping strategy to build the velocity model. This method improves the image resolution of Kirchhoff integral migration and reduces the computations of the reverse time migration. It combines the advantages of efficiency and accuracy of the two migration methods. Its application in tunnel seismic prediction shows good results. Numerical experiments show that the imaging results of reverse time migration are better than the imaging results of Kirchhoff integral migration in many aspects of tunnel prediction. Field data show that this method has efficient computations and can establish a reasonable velocity model and a high quality imaging section. Combination with geological information can make an accurate prediction of the front of the tunnel geological ...
2010-09-01
Code Verification by the Method of Manufactured Solutions
Energy Technology Data Exchange (ETDEWEB)
A procedure for code Verification by the Method of Manufactured Solutions (MMS) is presented. Although the procedure requires a certain amount of creativity and skill, we show that MMS can be applied to a variety of engineering codes which numerically solve partial differential equations. This is illustrated by detailed examples from computational fluid dynamics. The strength of the MMS procedure is that it can identify any coding mistake that affects the order-of-accuracy of the numerical method. A set of examples which use a blind-test protocol demonstrates the kinds of coding mistakes that can (and cannot) be exposed via the MMS code Verification procedure. The principle advantage of the MMS procedure over traditional methods of code Verification is that code capabilities are tested in full generality. The procedure thus results in a high degree of confidence that all coding mistakes which prevent the equations from being solved correctly ...
2000-06-01
Automated bead-positioning system for measuring impedances of R-F cavity modes
Energy Technology Data Exchange (ETDEWEB)
We describe a fully automated bead puller system which uses stepping motors to position the bead, and an HP-8510 network analyzer to measure the resulting frequency shifts, both devices being under computer control. Longitudinal motion of the bead is used for measurement of cavity shunt impedance. In addition, azimuthal scans at fixed longitudinal position aid in determining the multipole character of higher-order modes. High sensitivity/accuracy is made possible by measuring phase shifts at the unperturbed resonant frequencies (rather than frequency shifts themselves), thereby permitting averaging factors of > 500 with only modest increases in data acquisition time. Sample measurements will be presented. A comprehensive analysis of the experimental results is presented in an accompanying paper.
1993-05-01
Energy Technology Data Exchange (ETDEWEB)
This volume is based on the proceedings of the CERN Accelerator School's course on Applied Geodesy for Particle Accelerators held in April 1986. The purpose was to record and disseminate the knowledge gained in recent years on the geodesy of accelerators and other large systems. The latest methods for positioning equipment to sub-millimetric accuracy in deep underground tunnels several tens of kilometers long are described, as well as such sophisticated techniques as the Navstar Global Positioning System and the Terrameter. Automation of better known instruments such as the gyroscope and Distinvar is also treated along with the highly evolved treatment of components in a modern accelerator. Use of the methods described can be of great benefit in many areas of research and industrial geodesy such as surveying, nautical and aeronautical engineering, astronomical radio-interferometry, metrology of large components, deformation studies, ...
1987-01-01
Application of CaSO4:Dy (TLD-900) to diagnostic x-ray exposures
International Nuclear Information System (INIS)
The properties of a new commercial thermoluminescent dosimeter, CaSO4:Dy without a LiF binder (TLD-900) was studied for low-exposure measurements in diagnostic radiology. The former TLD-900 had a LiF binder (herein referred to as ''TLD-900/LiF''). The principle features of this dosimeter are its high sensitivity to low-energy radiation and its relatively low fading which permits measurements down to less than 2.6 X 10(-8) C kg (0.1 mR) with an accuracy better than 20%. The characteristics, annealing procedures, light sensitivity, energy response, reproducibility, and fading, of TLD-900 are discussed and compared with TLD-900/LiF. When the precautions presented in this paper are used, the dosimeters can be used for the measurement of x-ray exposures.
International Nuclear Information System (INIS)
A prospective comparative study with pathology was performed to assess the clinical value of Computed Tomography (CT) and endoscopic ultrasound (EUS) for nodal staging in lung cancer. A total of 329 nodal stations were dissected or sampled and 755 lymph nodes were examined at histology. On a pre-station basis, CT had greater sensitivity (74%) than EUS (56%), but EUS was more specific (83% versus 93%). The accuracy rates of the two techniques were similar. In conclusion, endoscopic ultrasound should be part of a routine preoperative diagnostic approach to non-small-cell lung cancer., because of its high specificity. Results can be improved when EUS and CT are combined., which suggests that these imaging modalities should be used together in selected patients for the noninvasive staging of non-small-cell lung cancer to identify local lymphatic spread.
1999-01-01
A Study on Feature Selection Techniques in Educational Data Mining
Educational data mining (EDM) is a new growing research area and the essence of data mining concepts are used in the educational field for the purpose of extracting useful information on the behaviors of students in the learning process. In this EDM, feature selection is to be made for the generation of subset of candidate variables. As the feature selection influences the predictive accuracy of any performance model, it is essential to study elaborately the effectiveness of student performance model in connection with feature selection techniques. In this connection, the present study is devoted not only to investigate the most relevant subset features with minimum cardinality for achieving high predictive performance by adopting various filtered feature selection techniques in data mining but also to evaluate the goodness of subsets with different cardinalities and the quality of six filtered feature selection algorithms in terms of F-measure ...
2009-01-01
This contribution deals with identification of fractional-order dynamical systems. System identification, which refers to estimation of process parameters, is a necessity in control theory. Real processes are usually of fractional order as opposed to the ideal integral order models. A simple and elegant scheme of estimating the parameters for such a fractional order process is proposed. This method employs fractional calculus theory to find equations relating the parameters that are to be estimated, and then estimates the process parameters after solving the simultaneous equations. The said simultaneous equations are generated and updated using particle swarm optimization (PSO) technique, the fitness function being the sum of squared deviations from the actual set of observations. The data used for the calculations are intentionally corrupted to simulate real-life conditions. Results show that the proposed scheme offers a very high degree of ...
2008-01-01
International Nuclear Information System (INIS)
The real parts of the optical model potentials for 104 MeV alpha-particle and 156 MeV "6Li ion scattering from "4"0,"4"8Ca are calculated in terms of folding model approaches. The validity of different procedures is tested by comparing the differential cross section predictions with experimental data measured with high angular accuracy. It is found that a refined folding potential accounting for density dependence of an effective nucleon-nucleon interaction is appropriate for alpha particle scattering without any parameter adjustment. However, for "6Li ion scattering renormalization of the depth of the real potentials is necessary. (orig.).
Abstract Background: Aution Max AX-4030, a test strip analyzer recently introduced to the market, represents an upgrade of the Aution Max AX-4280 widely employed for urinalysis. This new instrument model can allocate two different test strips at the same time. In the present study the two instruments have been compared together with the usage of Uriflet 9UB and the recently produced Aution Sticks 10PA urine strips, the latter presenting an additional test area for the measurement of urinary creatinine. Methods: Imprecision and correlation between instruments and strips have been evaluated for chemical-physical parameters. Accuracy was evaluated for protein, glucose and creatinine by comparing the semi-quantitative results to those obtained by quantitative methods. The well-known interference effect of high ascorbic acid levels on urine glucose test strip determination was evaluated, ascorbic acid influence was also evaluated on protein and ...
2011-09-26
International Nuclear Information System (INIS)
In various situations, measurements in prompt gamma neutron activation analysis (PGNAA) are performed to determine the amount of an elemental impurity relative to that of a major constituent of the matrix. An example of this is the measurement of hydrogen concentration in a metallic matrix. In all such cases, a major contributor to the uncertainty in the measurement is the uncertainty in the ratio of the high-purity germanium (HPGe) detector full-energy peak efficiency for the gamma-ray lines of interest (i.e., impurity and matrix gammas). Usually, the ratio is derived from the relative peak efficiency curve, which is determined using isotopic standards that emit multiple gamma ray lines (e.g., "1"5"2Eu) in the energy range <3000 keV, or using prompt gamma radionuclides (e.g., "1"4N, "3"5Cl) in the energy range >3000 keV. In either case, the uncertainty in the ratio of the peak efficiency values derived from such measurements will be on the order of a few ...
2001-06-17
Energy Technology Data Exchange (ETDEWEB)
Twenty-four patients were studied with both /sup 201/Tl-thallus chloride and /sup 99m/Tc-TBI scintigraphy following exercise. Comparison of the two agents in detecting segmental myocardial ischemia and scar was made in 18 patients with evidence of coronary artery disease on /sup 201/Tl-thallous chloride scintigraphy. Agreement between the two studies was observed in 77% (125 of 162) of left ventricular segments, suggesting that /sup 99m/Tc-TBI can be used as a myocardial perfusion agent. Limitations were related to early high background activity from lungs and liver. The high lung activity and early myocardial redistribution within the 1st hour contributed to the failure of /sup 99m/Tc-TBI to detect 16 segmental defects seen in the immediate post-exercise thallous chloride scan. Persistently high liver activity additionally affected accurate interpretation in the left ventricular segments close to the diaphragm. Improvement ...
1986-10-01
Noise bias in the refinement of structures derived from single particles
Energy Technology Data Exchange (ETDEWEB)
One of the main goals in the determination of three-dimensional macromolecular structures from electron microscope images of individual molecules and complexes (single particles) is a sufficiently high spatial resolution, about 4 A, at which the interpretation with an atomic model becomes possible. To reach high resolution, an iterative refinement procedure using an expectation maximization algorithm is often used that leads to a more accurate alignment of the positional and orientational parameters for each particle. We show here the results of refinement algorithms that use a phase residual, a linear correlation coefficient, or a weighted correlation coefficient to align individual particles. The algorithms were applied to computer-generated data sets that contained projections from model structures, as well as noise. The algorithms show different degrees of over-fitting, especially at high resolution where the signal is ...
2004-12-15
National and International Security Applications of Cryogenic Detectors - Mostly Nuclear Safeguards
International Nuclear Information System (INIS)
As with science, so with security--in both arenas, the extraordinary sensitivity of cryogenic sensors enables high-confidence detection and high-precision measurement even of the faintest signals. Science applications are more mature, but several national and international security applications have been identified where cryogenic detectors have high potential payoff. International safeguards and nuclear forensics are areas needing new technology and methods to boost speed, sensitivity, precision and accuracy. Successfully applied, improved nuclear materials analysis will help constrain nuclear materials diversion pathways and contribute to treaty verification. Cryogenic microcalorimeter detectors for X-ray, gamma-ray, neutron, and alpha-particle spectrometry are under development with these aims in mind. In each case the unsurpassed energy resolution of microcalorimeters reveals previously invisible ...
2009-12-16
Lightning performance assessment of Hellenic high voltage transmission lines
Energy Technology Data Exchange (ETDEWEB)
A methodology for assessing the lightning performance of Hellenic high voltage transmission lines has been developed. Its main advantage is that the analysed transmission line is divided into regions and the analysis is conducted separately for each one region, taking into account the individual characteristics, which exist in each one of them. The developed approach intends to offer more accuracy in the assessment of lightning performance of Hellenic high voltage transmission lines and of similar lines, where they run at the same time through a plain region, a coastline and/or a mountainous region. The aims of the paper are to describe in detail the proposed methodology and to present results obtained by its application on operating Hellenic transmission lines of 150 and 400 kV. The computed results are compared with the results produced by another software tool published in the technical literature and with the real ...
2008-04-15
Benefits of the use of radioisotopes in industrial gauging and control
International Nuclear Information System (INIS)
Since the radiometric measuring technique was introduced for industrial measuring and control engineering 15 to 20 years ago, the advantages of this technique have become more and more evident and have led to its world-wide application. In the last 15 to 20 years this method has become the standard one in this field. Its major advantages as compared with conventional methods are: contactless measurement; high reliability and accuracy; no mechanically moving parts; and no maintenance required. Despite higher investment costs the application of this method is paid off within a very short time owing to a higher output and the savings in maintenance costs. Some chemo-technical methods can be realized on a grand scale only when radiometric measuring equipment is used - e.g., urea plants, high-pressure polyethylene production. Especially in moisture measurements of blast-furnace coke are the economical advantages significant. ...
Energy Technology Data Exchange (ETDEWEB)
Negative ion electrospray ionization (ESI) coupled with high field Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) allows for the direct detection of acidic NSO compounds in petroleum. The technique requires no chromatographic separation, is able to distinguish 18 different compound classes (e.g., neutral nitrogen, carboxylic acids and oxygenates), and can identify {approx}14,000 distinct masses by ultra-high mass resolution and mass accuracy. We previously studied three crude oils from different geological origins [Organic Geochemistry 33 (2002b) 743-759]. Here, we expand our research by comparing two source-equivalent Smackover oils of different levels of thermal maturity. We observe clear differences in the distribution of NSO compound classes, types (number of rings plus double bonds within a class), and number of alkyl carbons. With increasing thermal stress, the relative amount of sulfur and ...
2004-07-01
The urine dipstick test useful to rule out infections. A meta-analysis of the accuracy
UK PubMed Central (United Kingdom)
BackgroundMany studies have evaluated the accuracy of dipstick tests as rapid detectors of bacteriuria and urinary tract infections (UTI). The lack of an adequate explanation for...Full Text Available
UK PubMed Central (United Kingdom)
BackgroundClinical experience with the continuous glucose monitoring systems (CGMS) is limited in Korea. The objective of this study is to evaluate the accuracy of the CGMS and the...Full Text Available
2010-12-01
Principle of pulse frequency measurement and methods for improving frequency meters accuracy
Energy Technology Data Exchange (ETDEWEB)
Specificity of the pulses mean frequency measurement (the pulses being generated in a stochastic process) is described. Status of the domain of analog frequency meters is presented. Methods of increasing accuracy of such meters are discussed.
1980-01-01
Principle of pulse frequency measurement and methods for improving frequency meters accuracy
International Nuclear Information System (INIS)
Specificity of the pulses mean frequency measurement (the pulses being generated in a stochastic process) is described. Status of the domain of analog frequency meters is presented. Methods of increasing accuracy of such meters are discussed. (author).
1980-01-01
UK PubMed Central (United Kingdom)
OBJECTIVE—To validate the accuracy of the prognostic significance of non-invasive clinical diagnostic indices as predictors of sustained ventricular tachycardia (sVT) or fibrillation...Full Text Available
1999-06-01
Unique approach to an old problem: New technology helps BC Hydro locate heat resistance
Energy Technology Data Exchange (ETDEWEB)
BC Hydro`s approach to improve the performance of its underground transmission lines by employing new computer technology with fibre optic cables was described. Known as Distributed Temperature Sensing (DTS), the technology is expected to increase the capacity of the most heavily-loaded sections of its seven kilometer underground 230 kV transmission system in the Greater Vancouver area. Although it is also a concern in overhead wires, heating is particularly problematic in underground cable systems. DTS uses opto-electronic equipment to launch a laser light down conventional communications-grade fibre optic cables, installed in the same duct as the cables, or in a spare duct next to them. By using high speed measurements and computer processing, it is possible to determine the temperature all along the fibre with very high accuracy, and to locate any point along the length of the cable line to within two meters over ...
1997-06-01
The vital importance of GIS : a workshop in project siting and development
Energy Technology Data Exchange (ETDEWEB)
Geographic information system (GIS) technology is now being used by wind energy developers who are required to consider and accommodate a wide variety of environmental and social considerations. This poster presentation discussed some of the new features available in current GIS technologies. High resolution imagery from satellites is being used to verify the accuracy of collected spatial data, as well as to investigate potential locations for meteorological towers, turbine sites, and roads. Slopes are easily calculated using GIS software tools, and digital elevation data can be used with high resolution aerial photography to determine routes for new roads and to establish available sites for crane pads. The GIS tools allow developers to consider protected ecological areas, wetlands and forests, and gives them the ability to better report project development considerations at public consultations. Wind resource grid outputs ...
2010-07-01
Energy Technology Data Exchange (ETDEWEB)
{sup 99m}Tc-N-pyridoxyl-5-methyl-tryptophan (PMT) scintigraphy, which exhibits highly specific for the diagnosis of primary hepatocellular carcinoma (HCC), was performed for recurrent HCC following non-surgical treatment. Eighty-four patients (total 351 examinations) were selected for the study. The ability of PMT scintigraphy to diagnose recurrent HCC after treatment was compared with that of computed tomography, ultrasonography and angiography. The results showed that sixty-three (75%) of 84 cases demonstrated positive findings during our follow-up period, most of the tumors initially showing positive findings remained PMT positive when they recurred and PMT studies shortly after treatment demonstrated wider tracer uptake rather than the actual tumor area. In conclusion, PMT scintigraphy for patients with HCC after non-surgical treatment exhibited high accuracy in identifying viable HCC only for tumors indicating positive ...
1997-10-01
Quality Management for Neutron Transmutation Doping of Silicon Ingot in HANARO
Energy Technology Data Exchange (ETDEWEB)
By using this doping method, silicon semiconductors with extremely uniform dopant distributions can be produced, and this is the dominant advantage of NTD compared with a conventional chemical doping. Good uniformity of a dopant concentration is usually required for high power applications such as thyristor (SCR), IGBT, IGCT and GTO and for special sensors. Achieving an accurate neutron fluence corresponding to a target resistivity as well as a uniform irradiation is the prime target of a neutron irradiation for NTD. Generally, in order to reach an accurate neutron fluence, a real time neutron flux is monitored by a neutron detector such as a Self-powered Neutron Detector(SPND). And, after an irradiation, the total irradiation fluence is confirmed by measuring the absolute activity of a neutron activation sample that has been irradiated with a silicon ingot, and thus the SPND can be properly calibrated. Excellent irradiation uniformity and a ...
2007-10-15
Numerical modeling of slug flow initiation in a horizontal channels using a two-fluid model
International Nuclear Information System (INIS)
This paper presents a methodology for modeling slug initiation and growth in horizontal ducts. Transient two-fluid equations are solved numerically using a class of high-resolution shock capturing methods. The advantage of this method is that slug formation and growth in a stratified regime can be calculated directly from the solutions to the flow field differential equations. In addition, by using high-resolution shock capturing methods that do not contain numerical diffusion, the discontinuity generated by slugging in the flow field can be modeled with good accuracy. The two-fluid model is shown to be well-posed mathematically only under certain conditions. Under these circumstances, the two-fluid model is capable of correctly predicting and modeling the flow physics. When ill-posed, an unbounded instability occurs in the flow field solution, and the instability amplitude increases exponentially with decreasing mesh ...
2011-02-01
Masses of Neutron Stars in High-Mass X-ray Binaries with Optical Astrometry
Determining the type of matter that is inside a neutron star (NS) has been a long-standing goal of astrophysics. Despite this, most of the NS equations of state (EOS) that predict maximum masses in the range 1.4-2.8 solar masses are still viable. Most of the precise NS mass measurements that have been made to date show values close to 1.4 solar masses, but a reliable measurement of an over-massive NS would constrain the EOS possibilities. Here, we investigate how optical astrometry at the microarcsecond level can be used to map out the orbits of High-Mass X-ray Binaries (HMXBs), leading to tight constraints on NS masses. While previous studies by Unwin and co-workers and Tomsick and co-workers discuss the fact that the future Space Interferometry Mission should be capable of making such measurements, the current work describes detailed simulations for 6 HMXB systems, including predicted constraints on all orbital parameters. We find that the direct NS masses can be ...
2010-01-01
Imaging of salt structure; Gan`enso kozo no imaging
Energy Technology Data Exchange (ETDEWEB)
Due to the improvement of algorithm and the advancement of calculation performance, the imaging by depth migration before stacking is being put into practice from the viewpoint of both calculation cost and accuracy. A lot of imaging examples have been already reported from the survey areas with complicated velocity structures, such as the North Sea and the Gulf of Mexico. Effectiveness of the method has been confirmed. For imaging techniques in Japan National Oil Corporation and Japan Petroleum Exploration Co., Ltd., high-speed depth migration before stacking and high efficiency velocity structure estimation technique have been investigated. This paper describes necessary care to be taken when using depth focusing analysis (DFA) for correcting a velocity model, as an interim stage of case study. The results of depth migration before stacking using dip moveout (DMO) velocity were further inferior to the section obtained by ...
1996-10-01
International Nuclear Information System (INIS)
Turbulent heat transfer performance of a fuel rod with three-dimensional trapezoidal spacer ribs for high temperature gas-cooled reactors was studied for various Reynolds numbers using an annular channel at the same coolant condition as the reactor operation, maximum outlet temperature of 1000 C and pressure of 4 MPa, and analytically by a numerical simulation using the k-#epsilon# turbulence model. The turbulent heat transfer coefficients of the fuel rod were 18-80% higher than those of a concentric smooth annulus at a region of Reynolds number exceeding 2000. On the other hand, the predicted average Nusselt number of the fuel rod agreed well with the empirical correlation obtained from the experimental data within a relative error of 10% with Reynolds number of more than 5000. It was verified that the numerical analysis results had sufficient accuracy. Furthermore, the numerical prediction could clarify quantitatively the effects of the heat ...
Design of a welltest for determining two-phase hydraulic properties
Energy Technology Data Exchange (ETDEWEB)
This report describes the design of a well test to determine two-phase hydraulic properties of a low permeability, low porosity formation. Estimation of gas-related parameters in such formations is difficult using standard pumping tests mainly because of the strong fluctuations in the pressure and flow rate data which are a consequence of gas bubbles evolving in the test interval. Even more important is the fact that the data do not allow distinguishing among alternative conceptual models. The estimated parameters are therefore uncertain, highly correlated, and ambiguous. In this study we examine a test sequence that could be appended to a standard hydraulic testing program. It is shown that performing a series of water and gas injection tests significantly reduces parameter correlations, thus decreasing the estimation error. Moreover, the extended test sequence makes possible the identification of the model that describes relative permeabilities and capillary ...
1995-01-01
Energy Technology Data Exchange (ETDEWEB)
Crystallography and computer modeling have been used to exploit a previously unexplored channel in the glucocorticoid receptor (GR). Highly potent, nonsteroidal indazole amides showing excellent complementarity to the channel were designed with the assistance of the computational technique AlleGrow. The accuracy of the design process was demonstrated through crystallographic structural determination of the GR ligand-binding domain-agonist complex of the D-prolinamide derivative 11. The utility of the channel was further exemplified through the design of a potent phenylindazole in which structural motifs, seen to interact with the traditional GR ligand pocket, were abandoned and replaced by interactions within the new channel. Occupation of the channel was confirmed with a second GR crystal structure of this truncated D-alaninamide derivative 13. Compound 11 displays properties compatible with development as an intranasal solution formulation, ...
2010-09-17
International Nuclear Information System (INIS)
Electron probe microanalysis (EPMA) offers high sensitivity and high accuracy in quantitative measurements of chemical compositions and mass coverages. Owing to the low detection limits of the wavelength-dispersive technique, monolayers with mass coverages of about 0.05 pg cm z can be detected. Assuming a density of 5 g cm--3 this corresponds to a thickness of 0.1 nm. With these advantages in mind, EPMA was extended to depth profile analysis in the sub-micron range using a surface removal technique. The present paper shows how depth profile analysis can be improved by combining EPMA and the focused ion beam (FIB) technique. The focused ion beam system uses a Ga+ ion beam. The ion beam allows the milling of defined geometries on the nanometer scale, so that very shallow bevels with exactly defined angles in relation to the surface can be obtained. Low surface damage is expected due to low sputtering effects. Calibrated WDX ...
Cosmological Hydrodynamics with Adaptive Mesh Refinement a new high resolution code called RAMSES
A new N-body and hydrodynamical code, called RAMSES, is presented. It has been designed to study structure formation in the universe with high spatial resolution. The code is based on Adaptive Mesh Refinement (AMR) technique, with a tree based data structure allowing recursive grid refinements on a cell-by-cell basis. The N-body solver is very similar to the one developed for the ART code (Kravtsov et al. 97), with minor differences in the exact implementation. The hydrodynamical solver is based on a second-order Godunov method, a modern shock-capturing scheme known to compute accurately the thermal history of the fluid component. The accuracy of the code is carefully estimated using various test cases, from pure gas dynamical tests to cosmological ones. The specific refinement strategy used in cosmological simulations is described, and potential spurious effects associated to shock waves propagation in the resulting AMR grid are discussed and ...
2001-01-01
Energy Technology Data Exchange (ETDEWEB)
To evaluate the diagnostic accuracy of Fuji computed radiography (FCR) in the detection of interstitial pulmonary infiltrates, FCR life-size images at a pixel size of 0.1 mm were compared with conventional radiographs taken on the same day. Seventeen radiologists assessed the radiographs and FCR images of 56 cases, including 39 cases of various interstitial lung diseases such as interstitial pneumonia, pulmonary abnormalities associated with collagen disease, sarcoidosis, multiple pulmonary metastases, diffuse panbronchiolitis and pulmonary emphysema, and 17 normal controls. All of the pulmonary abnormalities were confirmed by high resolution CT. Observer performance tests were carried out using receiver operating characteristic analysis. In 21 cases of increased pulmonary density revealed by high resolution CT, FCR was significantly superior to conventional radiographs in the detection of reticular or linear shadows. In 11 ...
1991-11-01
International Nuclear Information System (INIS)
To evaluate the diagnostic accuracy of Fuji computed radiography (FCR) in the detection of interstitial pulmonary infiltrates, FCR life-size images at a pixel size of 0.1 mm were compared with conventional radiographs taken on the same day. Seventeen radiologists assessed the radiographs and FCR images of 56 cases, including 39 cases of various interstitial lung diseases such as interstitial pneumonia, pulmonary abnormalities associated with collagen disease, sarcoidosis, multiple pulmonary metastases, diffuse panbronchiolitis and pulmonary emphysema, and 17 normal controls. All of the pulmonary abnormalities were confirmed by high resolution CT. Observer performance tests were carried out using receiver operating characteristic analysis. In 21 cases of increased pulmonary density revealed by high resolution CT, FCR was significantly superior to conventional radiographs in the detection of reticular or linear shadows. In 11 ...
1991-01-01
International Nuclear Information System (INIS)
High-resolution sequence stratigraphy taking base-level cycles as interface of reference was developed rapidly in recent years. Its greatest predominance lies in that it can be applied to multi-controled continental sedimentary basins and can effectively improve accuracy and distinguishability of sequence stratigraphy analysis. Principles of base-level cycles can also be applied to the research and practice of the exploration and exploitation of sandstone-type uranium deposits as they control the spatial distribution, porosity, the permeability and the sealing ability of sandstone and mudstone, and stacking patterns of strata configuration. Taking Dongsheng uranium deposits as an example, the application of base-level cycles to exploration and exploitation of sandstone uranium deposits was analyzed. It is suggested that favorable strata framework of sandstone and mudstone was developed very well in the fluctuation of base-level cycles. Sand ...
2006-05-01
CyberKnife SRS: new technologies that enhance the treatment of cancer
International Nuclear Information System (INIS)
The CyberKnife Robotic Radiosurgery System (Accuracy Incorporated, Sunnyvale, CA, USA) is used worldwide to treat tumors and neurological disorders anywhere in the body with sub-millimetre beam delivery accuracy. Accuracy has developed a number of new technologies in recent years to enhance the treatment of cancer patients. Such new technologies include a fast Monte Carlo Dose Calculation algorithm, Sequential Optimization dose planning, the IrisTM Variable Aperture Collimator, an 800 MU/min Linear Accelerator, and Optimized Path Traversal. These technologies enable physicists and physicians to plan treatments quickly and easily and deliver them with unrivalled accuracy and precision
2008-11-26
An Experimental Investigation of Short Diffusers for Gas ...
... within an accuracy of +5 psig. 2. Starting Pressure and Diffuser Geometra Preliminary, tests indicated that the geometry suggested by Ref. ...
1974-06-01
Design of High-speed Wear Lifetime Tester of the Instrument Ball Bearings
Energy Technology Data Exchange (ETDEWEB)
The instrument ball bearings are the key components of movable components for various kinds of measuring and control instruments; they often operate in the environmental condition of high-speed and light preload. In general, the non metal, disposable oilimpregnated retainer material has been used for these kinds of high precision miniature bearing. The engineering practice shows that the common failure mode of them is the wear which appears under the condition of insufficient lubrication condition. As the results, the vibration and noise will be enlarged, so does the frictional torque, which makes the ball bearings to lose its original working accuracy. It is the lifetime test of bearings that can enable the designers and manufacturers to chose the material of the bearing properly, optimize the product structure, mend the manufacturing technique process, and to enhance the technical level of the bearing products ...
2006-10-15
International Nuclear Information System (INIS)
This work describes an experimental verification of the two-photon dose calculation engines available on the Helax-TMS (version 6.1) commercial radiotherapy treatment planning system. The performance of the pencil beam convolution and the collapsed cone superposition algorithms was examined for 4, 6, 15 MV beams, under a range of clinically relevant irradiation geometries. Comparisons against measurements were carried out in terms of absolute dose, thus assessment of the accuracy of monitor unit (MU) calculations was also carried out. Results show that both algorithms agree with measurement to acceptable tolerance levels in most cases in homogeneous water-equivalent media irradiated under full scatter conditions. The collapsed cone algorithm slightly overestimates the penumbra width and this is mainly due to discretization effects of the fluence matrix. The accuracy of this algorithm strongly depends on the resolution of the patient density ...
2003-09-07
Discrepancies in molar extinction coefficients of Fe"3"+ in Fricke dosimetry
International Nuclear Information System (INIS)
Values of the chemical yield, G, and of the molar extinction coefficient, epsilon, for Fricke dosimetry, have been recommended by ICRU. For epsilon, the value in ICRU Reports 17 and 21, 2205 1.mol"-"1.cm"-"1, based on an analysis of 83 reported values. It was suggested that, where neither a careful wavelength calibration nor absorbance linearity checks had been performed, a standard error of 1.5% should be assumed; otherwise 0.15% could be accepted. Alternatively, the accuracy in applying this chemical dose meter was considered improved if there was an independent determination of epsilon with the same spectrophotometer as was used for the determination of the optical density of irradiated Fricke solution. The accuracy claimed for both methods remains questionable, since no complete argumentation could be given for the differences of up to 13% in the published values. Taking into account the discussion of the sources of error by Bryant, ...
1977-12-09
Clinical application of dual energy subtraction in direct digital radiography of chest
International Nuclear Information System (INIS)
Objective: To discuss the clinical application value of dual energy subtraction (DES) in direct digital radiography of chest. Methods: 83 cases of chest digital radiography(DR) using double-energy subtraction (DES) were randomly selected, and three posterior-anterior (PA) chest films (standard image, bone image and soft tissue image) were obtained in each case, which is so called 'bone and soft tissue separated' technology. Results: With the aid of double energy subtraction (DES), the bony chest was subtracted, the sensitivity and specificity of pulmonary calcification were improved, and sensitivity of pulmonary nodes was also improved, enhancing the distinction between pulmonary benign or malignant lesions, enlightening the diagnosis of chest cage lesions, and showing a clear superiority in the detection of pulmonary nodes comparing to common chest films. The double energy subtraction (DES) films showed a higher diagnostic accuracy in the detection of bony cage ...
2009-02-01
Base-level cycles and episodic coal accumulation - case study of Dongsheng coalfield in Ordos basin
Energy Technology Data Exchange (ETDEWEB)
The advantage of high-resolution sequence stratigraphy, which takes base-levels as reference, is that it can be applied to continental depositional basins controlled by multiple factors and can effectively improve the accuracy and resolution of sequential stratigraphic analysis. Moreover, the principles of base-level cycles are also suitable for analyzing sequential stratigraphy in continental coal-bearing basins because of their accuracy in forecasting distribution of coal measures. By taking the Dongsheng coalfield in the Ordos basin as an example, the extensive application of base-level cycles in exploration and exploitation of coal is analyzed. The result shows that the Yan'an formation in the Dongsheng area is a long-term base-level cycle which is bordered by nonconformities and made up of five mid-term cycles and 13 short-term cycles. The long-term cycle and the mid-term cycles are obvious in comparison with ...
2006-12-15
International Nuclear Information System (INIS)
High-intensity contact ultrasound (HICU) under MRI guidance may provide minimally invasive treatment of endocavitary digestive tumors in the esophagus, colon or rectum. In this study, a miniature receive-only coil was integrated into an endoscopic ultrasound applicator to offer high-resolution MRI guidance of thermotherapy. A cylindrical plastic support with an incorporated single element flat transducer (9.45 MHz, water cooling tip) was made and equipped with a rectangular RF loop coil surrounding the active element. The integrated coil provided significantly higher sensitivity than a four-element extracorporeal phased array coil, and the standard deviation of the MR thermometry (SDT) improved up to a factor of 7 at 10 mm depth in tissue. High-resolution morphological images (T1w-TFE and IR-T1w-TSE with a voxel size of 0.25 x 0.25 x 3 mm3) and accurate thermometry data (the PRFS method with a voxel size of 0.5 x 0.5 x 5 ...
2008-11-21
International Nuclear Information System (INIS)
International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the absorbed dose in materials ...
2007-08-01
Studies on the diagnostic accuracy of lymphography
International Nuclear Information System (INIS)
Contradictory reports in the literature on the reliability of lymphography stimulated the authors to test the diagnostic accuracy, employing methods which are approximately analogous to practice, using carcinoma of the cervix as the model on which the study was carried out. Using 21 observers it was found that there was no correlation between their experience and on-target accuracy of the diagnosis. Good observers obtained an accuracy of 85% with good proportions between sensitivity in the recognition of detail, specificity and readiness to arrive at a decision on the basis of discriminatory ability. With the help of the concept of the ROC curves, the position taken up by the observers in respect of diagnostic decisions, and a complex manner of assessing the various characteristic factors determining diagnostic accuracy, are demonstrated. This form of test, which permits manipulation of different ...
X-ray zone plate fabrication using a focused ion beam
Energy Technology Data Exchange (ETDEWEB)
An x-ray zone plate was fabricated using the novel approach of focused ion beam (FIB) milling. The FIB technique was developed in recent years, it has been successfully used for transmission electron microscopy (TEM) sample preparation, lithographic mask repair, and failure analysis of semiconductor devices. During FIB milling, material is removed by the physical sputtering action of ion bombardment. The sputter yield is high enough to remove a substantial amount of material, therefore FIB can perform a direct patterning with submicron accuracy. The authors succeeded in fabricating an x-ray phase zone plate using the Micrion 9500HT FIB station, which has a 50 kV Ga{sup +} column. Circular Fresnel zones were milled in a 1.0-{micro}m-thick TaSiN film deposited on a silicon wafer. The outermost zone width of the zone plate is 170 nm at a radius of 60 {micro}m. An achieved aspect ratio was 6:1.
2000-08-16
Energy Technology Data Exchange (ETDEWEB)
Energy savings performance contracting (ESPC) is now receiving greater attention as a means of implementing large-scale energy conservation projects in housing. Opportunities for such projects exist for military housing, federally subsidized low-income housing, and planned communities (condominiums, townhomes, senior centers), to name a few. Accurate prior (to construction) estimates of the energy savings in these projects reduce risk, decrease financing costs, and help avoid post-construction disputes over performance contract baseline adjustments. This paper demonstrates an improved method of estimating energy savings before construction takes place. Using an engineering model calibrated to pre-construction energy-use data collected in the field, this method is able to predict actual energy savings to a high degree of accuracy. This is verified with post-construction energy-use data from a geothermal heat pump ESPC at Fort Polk, Louisiana. ...
1998-10-01
Energy Technology Data Exchange (ETDEWEB)
Energy savings performance contracting (ESPC) is now receiving greater attention as a means of implementing large-scale energy conservation projects in housing. Opportunities for such projects exist for military housing, federally subsidized low-income housing, and planned communities (condominiums, townhomes, senior centers), to name a few. Accurate prior (to construction) estimates of the energy savings in these projects reduce risk, decrease financing costs, and help avoid post-construction disputes over performance contract baseline adjustments. This paper demonstrates an improved method of estimating energy savings before construction takes place. Using an engineering model calibrated to pre-construction energy-use data collected in the field, this method is able to predict actual energy savings to a high degree of accuracy. This is verified with post-construction energy-use data from a geothermal heat pump ESPC at Fort Polk, Louisiana. ...
1998-01-01
Turbulent mixing in the foot piece of a HPLWR fuel assembly
International Nuclear Information System (INIS)
A homogeneous turbulent mixing of coolant flows with different temperatures at the fuel assembly inlets is an important requirement to minimize hot spots in a fuel assembly of a High Performance Light Water Reactor (HPLWR). Therefore, the mixing chamber between lower core plate, flow adjuster and the mixing chamber within the cluster foot piece diffuser have been investigated using the Computational Fluid Dynamics (CFD)-code Fluent 6.1 and its implemented k-#epsilon# model. The previously presented 3D-CAD-geometry has been simplified using Gambit 2.1.2 and consists of various inlet and outlet tubes or channels in the foot piece bottom plate, the lower core plate and the flow adjuster establishing the boundaries of two consecutive mixing chambers. The temperature distribution at the inlet of the sub-channels of the cluster fuel assemblies is presented. It reveals temperature variations at the coolant inlet of the nine fuel assemblies which are not acceptable. ...
2005-10-09
International Nuclear Information System (INIS)
In this thesis, a new ab-initio method for molecular dynamics within the framework of density functional theory was developed and implemented. It is strongly related to the projector-augmented-wave method (PAW) by P. Bloechl, but also includes elements of a pseudocharge method proposed by M. Weinert for the full-potential linearized augmented plane wave method (FLAPW). Like the FLAPW-method, the PAW-method is an all-electron method. In the later case, the hamiltonian takes quite a simple form similar to the one obtained when using normconserving Kleinman-Bylander-type pseudopotentials or ultrasoft Vanderbilt pseudopotentials. The PAW-method allows for an efficient calculation of systems containing virtually any element of the periodic table, including those which require high numerical effort when treated using normconserving pseudopotentials (e.g. 2p-elements like oxygen or 3d-transitional metals like copper). In addition, a higher accuracy ...
Energy Technology Data Exchange (ETDEWEB)
A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above mentioned image processings are adopted, FCR can be used for the diagnosis of pneumoconiosis with the same ...
1993-06-01
The application of the Fuji Computed Radiography system for the diagnosis of pneumoconiosis
International Nuclear Information System (INIS)
A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above mentioned image processings are adopted, FCR can be used for the diagnosis of pneumoconiosis with the same ...
1993-01-01
The MonoPrep Pap Test (MPPT; MonoGen, Lincolnshire, IL) is a novel, liquid-based specimen collection and processing technology for cytologic and molecular testing. Its usefulness in the detection of cervical cancer and its precursors was evaluated in a multicenter, masked, adjudicated, split-sample study of 10,739 samples. After preparation of a conventional smear, the residuum on the collection device was rinsed into a collection vial from which an MPPT slide was prepared. Accuracy was assessed by masked reference interpretation by an independent pathologist. Slides prepared by MPPT, compared with smears, yielded statistically significant increases in relative sensitivity for atypical squamous cells of undetermined significance and worse, atypical squamous cells, cannot exclude high-grade squamous intraepithelial lesion/atypical glandular cells and worse, and low-grade squamous intraepithelial lesion and worse. There was no significant ...
2008-02-01
Gravitational parity violation is a possibility motivated by particle physics, string theory and loop quantum gravity. One effect of it is amplitude birefringence of gravitational waves, whereby left and right circularly-polarized waves propagate at the same speed but with different amplitude evolution. Here we propose a test of this effect through coincident observations of gravitational waves and short gamma-ray bursts from binary mergers involving neutron stars. Such gravitational waves are highly left or right circularly-polarized due to the geometry of the merger. Using localization information from the gamma-ray burst, ground-based gravitational wave detectors can measure the distance to the source with reasonable accuracy. An electromagnetic determination of the redshift from an afterglow or host galaxy yields an independent measure of this distance. Gravitational parity violation would manifest itself as a discrepancy between these two ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
TENSOMAX enables on-line monitoring of the thermal stress of the shaft to be performed in steam turbines, for which the TURBOMAX probe cannot be installed near the critical area of the shaft. TENSOMAX provides an alternative to the TURBOMAX with a slightly reduced accuracy of the simulation of the temperature distribution in the shaft. The high value placed on the operational performance of TENSOMAX remains, viz. that even with older turbines, and particularly in the case of turbines rehabilitated with a new shaft, careful and transparent operation is assured. (orig.) [German] Die Einrichtung TENSOMAX ermoeglicht eine Ueberwachung der thermischen Beanspruchung der Welle bei Dampfturbinen, bei denen die TURBOMAX-Sonde in der Turbine nahe der kritischen Stelle der Welle nicht einsetzbar ist. Daher stellt der TENSOMAX unter Beruecksichtigung minimaler Ungenauigkeit aufgrund der Nachbildung der Waermeuebergangszahl eine vorteilhafte Alternative zum ...
2000-07-01
Study on the time-domain electromagnetic responses; TDEM ho ni okeru denji oto ni tsuite
Energy Technology Data Exchange (ETDEWEB)
With an objective to perform three-dimensional analysis with high accuracy in using the electromagnetic exploration method, characteristics in electromagnetic response were analyzed, and conditions for acquiring necessary data were discussed. The discussion defined a parameter called `response anomaly` which uses response from media to standardize response only from substances with abnormal resistivity. The receivers were located uniformly on the same plane, and the response anomaly was derived from electromagnetic response from each of the three horizontal and vertical components at each receiving point, which was expressed as a contour map. The parameter for the abnormal body was consisted of location and resistivity contrast with media. Discussions using the contour map were given on the response when these factors for the parameter were varied. As a result, it was found that the response anomaly appears in the form that reflects the ...
1997-05-27
Energy Technology Data Exchange (ETDEWEB)
Results from ultimate analysis, proximate and petrographic analyses of a wide range of Kentucky coal samples were used to predict coal rank parameters (vitrinite maximum reflectance (R{sub max}) and gross calorific value (GCV)) using multivariable regression and artificial neural network (ANN) methods. Volatile matter, carbon, total sulfur, hydrogen and oxygen were used to predict both R{sub max} and GCV by regression and ANN. Multivariable regression equations to predict R{sub max} and GCV showed R{sup 2} = 0.77 and 0.69, respectively. Results from the ANN method with a 2-5-4-2 arrangement that simultaneously predicts GCV and R{sub max} showed R{sup 2} values of 0.84 and 0.90, respectively, for an independent test data set. The artificial neural network method can be appropriately used to predict R{sub max} and GCV when regression results do not have high accuracy. (author)
2010-07-01
International Nuclear Information System (INIS)
In this paper, molecular quantum computation is numerically studied with the quantum search algorithm (Grover's algorithm) by means of optimal control simulation. Qubits are implemented in the vibronic states of I_2, while gate operations are realized by optimally designed laser pulses. The methodological aspects of the simulation are discussed in detail. We show that the algorithm for solving a gate pulse-design problem has the same mathematical form as a state-to-state control problem in the density matrix formalism, which provides monotonically convergent algorithms as an alternative to the Krotov method. The sequential irradiation of separately designed gate pulses leads to the population distribution predicted by Grover's algorithm. The computational accuracy is reduced by the imperfect quality of the pulse design and by the electronic decoherence processes that are modeled by the non-Markovian master equation. However, as long as we focus on the population ...
2010-04-01
Semirelativistic technique for k#centre dot#p calculations: Optical properties of Pd and Pt
International Nuclear Information System (INIS)
A semirelativistic two-component extended linear augmented plane-wave k#centre dot#p method is described. In order to ensure a high accuracy of the k#centre dot#p method, it is necessary to include into the radial-basis set, which is used for the augmentation of the plane waves, functions that are neither solutions of the Schrodinger equation nor their energy derivatives. The usual scalar relativistic procedure, which is nonlinear in energy, is not applicable to such basis sets. As an alternative, we suggest an approximation to the Foldy-Wouthuysen Hamiltonian that produces an explicitly Hermitean matrix in the augmented plane wave representation. The technique is applied to the calculation of the full dielectric matrix and optical properties of palladium and platinum metals over the photon energy region up to 100 eV. Special attention is paid to the far ultraviolet absorption by the excitations of semicore Pd 4p and Pt 5p and 4f states. A ...
2001-06-15
Energy Technology Data Exchange (ETDEWEB)
Microhardness decarburization profiles are often used in the industry to estimate the carbon distribution in steels. For quantitative evaluation, an analysis based on diffusion theory must be performed, the fundamentals and mathematical basics of which are presented. If the relationship between hardness and carbon content is known, microhardness-distance curves of steels can be analyzed in this way. For martensitic grades, for instance, a linearized expression holds in the concentration range from 0.15 to 0.6 m.% C. Microhardness depth profiles of higher carbon steels and other microstructures, however, are also evaluated in the literature. The applicability of quantitative diffusion modeling is discussed in detail. Through hardenable rolling bearing steel 100Cr6 (1.3505, SAE 52100) serves as model material: carbon concentration-distance curves are measured with high accuracy by secondary ion mass spectrometry (SIMS) and compared with ...
2007-07-01
Ray Tracing Simulations of Weak Lensing by Large-Scale Structure
We investigate weak lensing by large-scale structure using ray tracing through N-body simulations. Photon trajectories are followed through high resolution simulations of structure formation to make simulated maps of shear and convergence on the sky. Tests with varying numerical parameters are used to calibrate the accuracy of computed lensing statistics on angular scales from about 1 arcminute to a few degrees. Various aspects of the weak lensing approximation are also tested. For fields a few degrees on a side the shear power spectrum is almost entirely in the nonlinear regime and agrees well with nonlinear analytical predictions. Sampling fluctuations in power spectrum estimates are investigated by comparing several ray tracing realizations of a given model. For survey areas smaller than a degree on a side the main source of scatter is nonlinear coupling to modes larger than the survey. We develop a method which uses this effect to estimate ...
2000-01-01
Radionuclide release rates from spent fuel for performance assessment modeling
Energy Technology Data Exchange (ETDEWEB)
In a scenario of aqueous transport from a high-level radioactive waste repository, the concentration of radionuclides in water in contact with the waste constitutes the source term for transport models, and as such represents a fundamental component of all performance assessment models. Many laboratory experiments have been done to characterize release rates and understand processes influencing radionuclide release rates from irradiated nuclear fuel. Natural analogues of these waste forms have been studied to obtain information regarding the long-term stability of potential waste forms in complex natural systems. This information from diverse sources must be brought together to develop and defend methods used to define source terms for performance assessment models. In this manuscript examples of measures of radionuclide release rates from spent nuclear fuel or analogues of nuclear fuel are presented. Each example represents a very different approach to obtaining a ...
1994-11-01
Radioanalytical methods of rare earth element determination
International Nuclear Information System (INIS)
Instrumental neutron activation analysis (INAA) and radionuclide X-ray fluorescence analysis (RXFA) were used for the determination of rare earth elements. For INAA, solution obtained by sample decomposition was dripped onto filter paper, enclosed and sealed into a polyethylene foil. The sample was activated in reactor WWR-S over a period of 4 to 6 hours with a neutron fluence of 10"1"3cm"-"2. Gamma radiation measurement was carried out with a planar and a coaxial HP-Ge detector in three decay periods. La, Ce, Nd, Sm, Eu, Gd, Tb, Ho, Tm, Yb and Lu were determined. The advantage of the method is its accuracy and high sensitivity, the disadvantage is the time-consuming analysis. The RXFA method was used as a rapid and operative method for the analysis of loose ore samples, aqueous and organic solutions of rare earth elements. For exciting X-ray radiation, "2"4"1Am was used and the radiation of K-lines was detected with a planar Si(Li) detector. ...
1989-06-01
International Nuclear Information System (INIS)
A case-control study on lung cancer and radon exposure in dwellings has been carried out in Lazio, a high indoor radon region of Central Italy. A total of about 400 cases and 400 controls were recruited and radon concentration was measured in a total of about 1850 dwellings. In each dwelling, radon concentration measurement devices were placed in both the main bedroom and living room for two consecutive six-month periods. Each radon device, enclosed in a sealed polyethylene bag, contains two LR 115 detectors, each being covered by a thin absorber to reduce the alpha-energy within the detector sensitive range. A quality assurance program, described in this paper, was applied in order to reduce radon concentration measurement uncertainty, which have a significant impact on the results of an epidemiological study. The reported internal quality control and intercomparison results are compared with the results of other studies, and show that the radon measurement ...
2003-06-01
Energy Technology Data Exchange (ETDEWEB)
The objective of this study is to develop an artificial neural network (ANN) model to predict the thermal conductivity of ethylene glycol-water solutions based on experimentally measured variables. The thermal conductivity of solutions at different concentrations and various temperatures was measured using the cylindrical cell method that physical properties of the solution are being determined fills the annular space between two concentric cylinders. During the experiment, heat flows in the radial direction outwards through the test liquid filled in the annual gap to cooling water. In the steady state, conduction inside the cell was described by the Fourier equation in cylindrical coordinates, with boundary conditions corresponding to heat transfer between the solution and cooling water. The performance of ANN was evaluated by a regression analysis between the predicted and the experimental values. The ANN predictions yield R{sup 2} in the range of 0.9999 and MAPE in the range of ...
2009-10-15
Phase separation in H2O:N2 mixture - molecular dynamics simulations using atomistic force fields
Energy Technology Data Exchange (ETDEWEB)
A class II atomistic force field with Lennard-Jones 6-9 nonbond interactions is used to investigate equations of state (EOS) for important high explosive detonation products N{sub 2} and H{sub 2}O in the temperature range 700-2500 K and pressure range 0.1-10 GPa. A standard 6th order parameter-mixing scheme is then employed to study a 2:1 (molar) H{sub 2}O:N{sub 2} mixture, to investigate in particular the possibility of phase-separation under detonation conditions. The simulations demonstrate several important results, including: (1) the accuracy of computed EOS for both N{sub 2} and H{sub 2}O over the entire range of temperature and pressure considered; (2) accurate mixing-demixing phase boundary as compared to experimental data; and (3) the departure of mixing free energy from that predicted by ideal mixing law. The results provide comparison and guidance to state-of-the-art chemical kinetic models.
2006-09-25
Energy Technology Data Exchange (ETDEWEB)
A method of kinetic analysis applicable to non-isothermal oxidation processes of ceramic nanocomposites is presented using Ti-Si-C-N powder as the substrate. The nanoparticle size and phase composition were determined using high-resolution transmission electron microscopy and X-ray diffraction (XRD). Thermogravimetric measurements were carried out for powder samples in dry air in the temperature range 298-1770 K. The following heating rates were applied: 3, 5, 10, 20 K min{sup -1}. Mass spectrometry was used to analyze gaseous oxidation products and solid products were identified by the XRD technique. The Coats-Redfern equation was applied for the kinetic analysis. For each stage of the oxidation kinetic models, the best accuracy was achieved using a series of criteria, and then the A and E parameters of the Arrhenius equations were estimated. Both linear regression and artificial neural networks were applied in testing kinetic models.
2008-08-15
International Nuclear Information System (INIS)
In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component of a fiber-optic radiation detector and to ...
2007-08-21
Measurement of "2"3"3U(n,f) cross-section at n_TOF facility. Statistical analysis
International Nuclear Information System (INIS)
The "2"3"3U(n, f) cross-section has been measured at n_TOF in a wide energy range with a dedicated fission ionization chamber. We report here the results from 0.30 meV to 1 MeV neutron energy. The "2"3"3U(n, f) cross-section has been determined relative to a reference sample of "2"3"5U(n, f) measured simultaneously with the same detector. The very high instantaneous neutron flux and the intrinsically low background of the n TOF installation result in an accuracy around 3% in the whole energy range, while the energy resolution of the neutron beam allows for an accurate description of the fission cross-section by means of R-matrix analysis over a wide energy range. The present data provide the basis for a more precise evaluation of the "2"3"3U fission cross-section, and for improving the reliability of databases needed for the design of new energy systems based on the Th/U cycle. (Author)
2009-02-01
Energy Technology Data Exchange (ETDEWEB)
Magnetic resonance imaging (MRI) has rapidly attained a major position among the examinations used in the diagnostic approach of multiple sclerosis because it is highly sensitive in demonstrating lesions. However, these lesional images may have several meanings, and there is the problem of distinguishing between oedema, which is said to reflect recent lesions, and gliosis which is thought to betray old lesions. The intrinsic MRI parameters studied (i.e. relaxation times) are unable to make this distinction, whereas it is provided by paramagnetic contrast media such as gadolinium. There is no correlation between the changes observed at MRI and the severity of the disease. Another problem is the accuracy of lesion localization, since visualization is predominantly macroscopic. This raises several questions about the demonstration of correlations between clinical signs and site of the lesion(s). At the moment, several teams of neuroradiologists ...
1991-09-15
Electron impact excitation cross sections in F-like selenium
Cross sections for excitation induced by electron collision between low-lying 1s{sup 2}2s{sup 2}2p{sup 5} and 1s{sup 2}2s2p{sup 6} states of f-like selenium and from these states to singly excited states with the excited electron occupying the M shell have been calculated by relativistic distorted-wave Born procedures. The GRASP{sup 2} code was used for the atomic structure calculations. The continuum orbitals for the construction of continuum states were computed in the distorted-wave approximation, in which the distorted-wave potential used was the spherically averaged potential of the nucleus plus the potential of the bound electrons of the bound state. The cross sections for excitations were computed first by a 233-level multiconfiguration Dirac-Fock (MCDF) configuration expansion and then by a 279-level MCDF configuration expansion. The latter procedure, which also took into account contributions from all the participating singly excited N-shell states, was found to be necessary ...
1998-09-01
Energy Technology Data Exchange (ETDEWEB)
The paper summarizes the results obtained in two interview studies conducted in the communities of Storuman and Malaa in northern Sweden, 1995 and 1997. It highlights the similarities and differences with respect to the public participation and decision processes which preceded the respective referenda in the two communities. The presentation includes the arguments used by proponents and opponents, the changes over time, as well as the time frame and the information involved in the processes. It is concluded e.g. that local cultures, life-styles, knowledge of similar events, and the time for and management of the participation process are important and salient factors in the resulting social dynamics. Factors of possibly more fundamental importance were also discerned, however, including overall attitude to and valuation of nuclear power, perceptions of development, solidarity, power and power distribution in relation to current as well as future situations. It is furthermore concluded ...
1999-12-01
International Nuclear Information System (INIS)
Differential cross sections of elastic scattering of 104 MeV #alpha# particles from "2"0"4,"2"0"6,"2"0"8Pb have been measured with high angular accuracy. The analyses are based on a folding model treating the proton and neutron distributions independently. The proton distributions were taken from precise electron scattering results. The neutron distributions were parametrized by a modified Gaussian the parametrers of which were varied in order to fit the experimental cross sections. The resulting rms radii of the neutron distributions exceed the rms radii of the proton distributions by #DELTA#r=0.22 +- 0.09 fm for "2"0"4Pb, #DELTA#r = 0.19 +- 0.09 fm for "2"0"6Pb, and #DELTA#r = 0.30 +- 0.07 fm for "2"0"8Pb.
Energy Technology Data Exchange (ETDEWEB)
Largest coal mine fires in the world are reported from Jharia coalfield in Dhanbad district, Bihar State of India. In this paper we report the utility of day and night time Thematic Mapper thermal IR data (120 m x 120 m) for detecting and monitoring mine fires in Jharia. For this purpose, seven sets of TM data acquired between 1985 to 1995 have been analysed. Data processing methods include geometric and radiometric corrections, conversion of DN values to at-satellite temperatures and colour coding of temperature images. The pixel-integrated temperatures of 50{degrees}C and above have been classified as mine fires and achieved an accuracy of 81.2%. Also, assessed year wise, colliery-wise and geological formation-wise mine fire distribution in this area. Although TM thermal data is of coarser resolution, it enabled detection of mine fires mainly because of the large areal extent and high temperature range of mine fires. It is possible to detect ...
1996-08-01
Challenges in fabrication of 180deg magnet chamber
International Nuclear Information System (INIS)
180 deg magnet chamber is used in Folded Tandem Ion Accelerator for passage and 180 deg bending of ion beam. The chamber is placed between 180 deg terminal magnet (Electro-magnet), which is used for bending, and analysing the beams. Magnet with a particular magnetic field strength bends ions of only specified mass energy product through a precise path. There is also a space limitation in the direction of magnetic field. Both of them require the magnet chamber to be of a close tolerance. Accuracy of center distance between inlet and outlet port of the magnet chamber has to be at par with the concentricity of high energy and low energy beam line. To achieve this we started the fabrication of magnet chamber by following two methods: a) Circular rolling and bending of rectangular tube for 180 deg sector of magnet chamber b) Machining 180 deg sector in two half and welding. By first method we could not achieve the desired result although the method ...
2006-11-01
International Nuclear Information System (INIS)
The relevance of Quantum Electrodynamics (Qed) in contemporary atomic structure theory is reviewed. Recent experimental advances allow both the production of heavy ions of high charge as well as the measurement of atomic properties with a precision never achieved before. The description of heavy atoms with few electrons via the successive incorporation of one, two, etcetera photons in a rigorous manner and within the bound state Furry representation of Qed is technically feasible. For many-electron atoms the many-body (correlation) effects are very important and it is practically impossible to evaluate all the relevant Feynman diagrams to the required accuracy. Thus, it is necessary to develop a theoretical scheme in which the radiative and nonradiative effects are taken into account in an effective way making emphasis in electronic correlation. Preserving gauge invariance, and avoiding both continuum dissolution and variational collapse are ...
International Nuclear Information System (INIS)
In this paper a computational analysis of 11 fuel samples (seven UO_2 and four MOX) with a burn-up ranging from 20 MWd/kgHM up to 121 MWd/kgHM (HM: Heavy Metal) is carried out with the depletion module of the lattice code CASMO-4E [Rhod01, Rhod01b] using the neutron data libraries ENDF/B-VI and JEF-2.2 and a pin cell model. In order to assess the accuracy of the model and the depletion calculation in the determination of the isotopic inventory after several irradiation cycles, the calculated results were compared to experimental data gathered from a chemical isotopic analysis of the fuel samples performed at the Hot Laboratory at the Paul Scherrer Institut (PSI), Switzerland. Selected results of this comparison, which includes 54 isotopes (17 actinides and 37 fission products), are presented here. (orig.)
The major purpose of the work described in this report was to use diffusion modeling techniques to calculate the impact on ambient air quality of SO2 emissions from the ASARCO copper smelter in Tacoma, Washington for the existing smelter configuration (51-percent constant emissions control) and for 20 alternative smelter configurations with varying degrees of constant emissions control. The accuracy of the modeling techniques was established by the close correspondence obtained between calculated and observed short-term ground-level SO2 concentrations for 20 selected historical cases, when high hourly SO2 concentrations were measured in the area surrounding the smelter, as well as by the close agreement between calculated and observed annual average concentrations for 1972. The results of the model calculations show that the maximum allowable constant SO2 emission rate consistent with maintaining the Washington Department of Ecology (DOE) and ...
1976-07-01
Energy Technology Data Exchange (ETDEWEB)
As part of developing efforts for physical exploration technologies for oil reservoirs, this paper describes development of an active seismic while drilling (SWD). The SWD is a seismic exploration method to acquire records equivalent to VSP using seismic waves generated from a bit executing excavation, and is capable of detection and control on a real time basis during the excavation. However, the drawback is that it is subjected to a limitation in the bit. To eliminate this limitation, an artificial seismic source method was devised. In other words, this is an SWD utilizing an artificial seismic source. The contrivance is such that a shot sub containing a magnetic distortion oscillator is attached directly above a bit to generate vibration artificially, and try to utilize larger seismic energy by combining this vibration with that generated from the excavating bit. Frequency band in the seismic source is as narrow as nearly a single frequency waveform. Preparing a time-depth curve ...
1997-05-27
Energy Technology Data Exchange (ETDEWEB)
Purpose: The determination of tumor volume in ocular tumors is very important for the planning and success of radiation therapy. This study uses an animal model to evaluate the accuracy of MR-based volumetry of ocular tumors. Materials and methods: In a total of 25 porcine eyes obtained from the slaughterhouse, ocular tumors were produced by injecting a mixture of hand creme and Gd-DTPA under ophthalmoscopic guidance. The injected volume varied between 0.05 ml and 2.7 ml. The eyes were examined with a 1.5 Tesla scanner and a 4 cm circular surface coil especially developed for ocular MRI. After data transfer to a separate workstation, volumetric analysis was carried out by three independent radiologists using semiautomated software. The determined volume was compared with the injected volume. Results: Of the 25 prepared porcine eyes, 23 were suitable for volumetric analysis. The injection of the mixture of hand creme and GD-DTPA produced two different types of ...
2003-07-01
Wind Tunnel Flow Quality and Data Accuracy Requirements
... tests, one often encounters, for instance, separated flows with large ... It is suspected that the flow-quality criteria given in AGARD Report No. ...
1982-11-01
Prediction accuracy of a sample-size estimation method for ROC studies
UK PubMed Central (United Kingdom)
Rationale and ObjectivesSample-size estimation is an important consideration when planning a receiver operating characteristic (ROC) study. The aim of this work was...Full Text Available
2010-05-01
Cardiac Enzymes, Renal Failure and Renal Transplantation
UK PubMed Central (United Kingdom)
Diagnostic accuracy of the currently available serum markers of cardiac injury, such as myoglobin, creatine kinase and its myocardial isoform, are altered in patients with renal failure. It is shown...Full Text Available
2006-03-01
State of the Art Laser Induced Breakdown Spectroscopy
International Nuclear Information System (INIS)
Methods currently being used or developed for the elemental analysis of materials are chemical analysis, non-destructive inspection and calorimetry. The chemical analysis, which removes high-level radioactive elements through chemical treatments and then performs the quantitative analysis using the ICP-MS(Inductively Coupled Plasma - Mass Spectrometer) or the ID-MS(Isotope Dilution Mass Spectrometer), is recognized the most accurate. However, it requires a long, complex pre-treatment process in which a mass spectrometer could be contaminated. To solve this problem, a new method, which can be performed with high-level radioactivity and at high temperature, was desired. Such a method should also have the same accuracy as the chemical analysis, with a less possibility for instruments to be contaminated. In addition, as interests in the environment and the life quality are increased, a detailed analysis on ...
High pressure waterjets for oil containment in calm and wavy waters; a parametric study
International Nuclear Information System (INIS)
The use of high pressure waterjets (HPWJ) as oil barriers has been proposed and tested. It has been shown that a series of waterjets directed horizontally above the free water surface provide an effective means of containing or deflecting oil slicks. The waterjets generate a high speed air flow capable of moving the surface layer of the liquid. A numerical model is implemented to study the characteristics of the entrained turbulent air flow using the Spectral Element Method (SEM) and an algebraic turbulent model for the Reynolds stresses. A test of the code is done for turbulent Couette Flow to check the accuracy of the calculated shear stresses against published data. A parametric study is performed to evaluate the HPWJ system performance at various operating and design parameters which include manifold pressure, nozzle flow rate, nozzle characteristics, jet height and surface wave conditions. The total driving shear force ...
1994-01-01
Energy Technology Data Exchange (ETDEWEB)
Four HVDC (high voltage DC) {+-} 250kV submarine OF (oil-filled) cables are to be installed each capable of 1.4-million kW for one dipole channel and two returns for forwarding to Yura Switchyard a part of the power to be generated by a Tachibanawan coal-fired power plant to open in 2000. The first cable is now being laid. They are to cover a distance of 48km on the sea bottom, and their 190mm diameter is the largest in the world and this decreases the required number of cables for a reduction in the construction cost. The installation is executed by use of a dedicated cable laying ship loaded with cables. The ship is equipped with five thruster screws by adjusting which a cable is fed into the sea and laid on the bottom with high positional accuracy in all directions, and with a 10m-accurate DPS (Dynamic Positioning System) besides GPS (Global Positioning System). Operating on the sea bottom is a simultaneous ...
1998-07-01
Fabrication and testing of small scale mock-ups of ITER shielding blanket
International Nuclear Information System (INIS)
Small scale mock-ups of the primary first wall, the baffle first wall, the shield block and a partial model for the edge of the primary first wall module were designed and fabricated incorporating most of the key design features of the ITER shielding blanket. All mock-ups featured the DSCu heat sink, the built-in SS coolant tubes within the heat sink and the SS shield block. CFC tiles was used as the protection armor for the baffle first wall mock-up. The small scale shield block mock-up, integrated with the first wall, was designed to have a poloidal curvature specified in the ITER design. Fabrication routes of mock-ups were decided based on the single step solid HIP of DSCu/DSCu, DSCu/SS and SS/SS reflecting the results of previous joining techniques development and testing. For attaching the CFC tiles onto DSCu heat sink in the fabrication of the baffle first wall mock-up, a two-step brazing was tried. All mock-ups and the partial model were successfully fabricated with a ...
1998-09-01
This study presents the data of an evaluation of the automated Nuclisens easyMAG and EasyQ systems versus the Roche AmpliPrep-AMPLICOR combination for testing of high-volume human immunodeficiency virus (HIV) load. This represents a follow-up of a previous study investigating the performance of the real-time Nuclisens assay using the semiautomated NucliSENS miniMAG extraction procedure. Three hundred eighteen patient samples were analyzed using both methods. The easyMAG-EasyQ HIV type 1 system has a higher sensitivity and broader dynamic range than the Cobas AmpliPrep-AMPLICOR system when the standard Roche assay is used alone, 25 to 3,000,000 IU/ml versus 400 to 750,000 HIV RNA copies/ml, respectively. There was significant correlation between the assays (0.93; P < 0.0001), with good accuracy (percent similarity mean ? = 96%), good precision (percent similarity standard deviation = 4.97%), and overall good agreement with a low percent ...
2007-05-01
Evaluation of critical heat flux of tight lattice core with subchannel analysis code NASCA
International Nuclear Information System (INIS)
Reduced-Moderation Water reactor (RMWR) is a light water breeder reactor developed by Japan Atomic Energy Research Institute (JAERI). The RMWR comprises tight lattice fuel assemblies with gap clearance of around 1.0 mm to reduce water volume ratio to achieve a high conversion ratio. It is important to estimate the thermal hydraulic safety margin of the tight lattice core of the RMWR. In the present study, the boiling transition (BT) prediction performance of the subchannel analysis code NASCA developed for the current BWR cores was assessed for series of tight lattice critical heat flux (CHF) experiments performed in JAERI. The test section was a 7-rod bundle with rod diameter of 12.3 mm, rod gap of 1.0 mm and heated length of 1.8m. Axial power distribution was flat. With a simple subchannel model, the code overestimates the critical power in the high mass velocity region, although the predicted critical powers in the low mass velocity region ...
2003-04-20
Dose verification using a pelvic phantom in high dose rate (HDR) brachytherapy
Energy Technology Data Exchange (ETDEWEB)
High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom. In this study, the humanoid phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the humanoid phantom were then compared with the treatment planning system for the dose verification. The humanoid phantom needs to be designed such that the dose distributions can be quantitatively evaluated thermoluminescent dosimeter (TLD) chips with a dimension of 1/8 and film dosimetry with a spatial resolution of <1 mm used to measure the radiation dosages in the phantom. ...
2003-07-01
Energy Technology Data Exchange (ETDEWEB)
(1) To determine the accuracy of computed tomography (CT) in the evaluation of ligament tear and avulsion in patients with tibial plateau fracture. (2) To evaluate whether the presence or severity of fracture gap and articular depression can predict meniscal injury. A fellowship-trained musculoskeletal radiologist retrospectively reviewed knee CT and MRI examinations of 41 consecutive patients presenting to a level 1 trauma center with tibial plateau fractures. Fracture gap, articular depression, ligament tear and footprint avulsions were assessed on CT examinations. The MRI studies were examined for osseous and soft tissue injuries, including meniscal tear, meniscal displacement, ligament tear, and ligament avulsion. CT demonstrated torn ligaments with 80% sensitivity and 98% specificity. Only 2% of ligaments deemed intact on careful CT evaluation had partial or complete tears on MRI. Although the degree of fracture gap and articular depression was significantly ...
2007-02-15
Energy Technology Data Exchange (ETDEWEB)
Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T{sub 2}-weighted turbo-spin-echo (TSE) and T{sub 1}-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm{sup 2}. Lymph nodes with a diameter of {>=}8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes ({>=} 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of 24 cases MR findings were true negative (specificity 92%). Diagnostic accuracy was ...
1997-03-01
A unified Nonhydrostatic Multiscale Model on the Arakawa B grid (NMMB) designed for a broad range of spatial and temporal scales has been under development within the Earth System Modeling Framework (ESMF) at the National Centers for Environmental Prediction (NCEP) as a part of the new National Environmental Modeling System (NEMS). The model follows the general modeling philosophy of the NCEP's WRF NMM grid-point regional dynamical core. The model uses the regular latitude-longitude grid for the global domain, and a rotated latitude-longitude grid in regional applications. The nonhydrostatic component of the model dynamics is introduced through an add-on module that can be turned on or off depending on resolution. The "isotropic" quadratic conservative finite-volume horizontal differencing employed in the model conserves a variety of basic and derived dynamical and quadratic quantities and preserves some important properties of differential operators. Among these, the conservation of ...
2009-04-01
CFD investigation of balcony spill plumes in atria (part II)
Energy Technology Data Exchange (ETDEWEB)
This paper proposes an integrated method for using experimental data and CFD modeling to develop engineering correlations for atrium smoke management. Part I focused on the experimental program and validation of a CFD model of the experimental facility. Part II describes the extension of this model to a parametric study of balcony spill plumes. Smoke management in buildings during fire events often uses mechanical ventilation systems to maintain smoke layer elevation above a safe evacuation path. Design of these systems requires accurate correlations for the smoke production or mass flow rate of the buoyant fire plume. One design issue is the mass flow rate of fire plumes which spill out from a fire compartment, under a balcony and up through an atrium or other large volume. Current engineering correlations for these balcony spill plumes (BSPs) are based on a combination of one-tenth scale test data and theoretical analysis. The suitability of these correlations for real-scale designs ...
2005-07-01
CFD investigation of balcony spill plumes in atria (part II)
International Nuclear Information System (INIS)
This paper proposes an integrated method for using experimental data and CFD modeling to develop engineering correlations for atrium smoke management. Part I focused on the experimental program and validation of a CFD model of the experimental facility. Part II describes the extension of this model to a parametric study of balcony spill plumes. Smoke management in buildings during fire events often uses mechanical ventilation systems to maintain smoke layer elevation above a safe evacuation path. Design of these systems requires accurate correlations for the smoke production or mass flow rate of the buoyant fire plume. One design issue is the mass flow rate of fire plumes which spill out from a fire compartment, under a balcony and up through an atrium or other large volume. Current engineering correlations for these balcony spill plumes (BSPs) are based on a combination of one-tenth scale test data and theoretical analysis. The suitability of these correlations for real-scale designs ...
Numerical simulation of progressive inlet orifices in boiling water reactor fuel
International Nuclear Information System (INIS)
This thesis was carried out at Forsmark Nuclear Power Plant. The power plant in Forsmark consists of three boiling water reactors (BWR) which produce about 17% of Swedish electricity. In a BWR the nuclear reactions are used to boil water inside the reactor vessel. The water works both as a coolant and as a moderator and the resulting steam is used directly to run the turbines. A problem when running a BWR at low flow conditions is the density wave oscillations that might occur to the water flow inside the fuel assemblies. These oscillations arise due to the connection between power and flow rate in a heated channel with two-phase flow. In order to improve the stability performance of the channel an orifice plate is placed at the inlet of each fuel assembly. Today these orifice plates have sharp edges and a constant resistance coefficient. Experimental work has been done with progressive orifices, the edge of which is half-oval in shape. The advantage of progressive orifices is the ...
2004-01-01
Neutron cross-sections on minor actinides for next generation reactors: new data from n_TOF (CERN)
International Nuclear Information System (INIS)
Full text: Climatic problems associated to the greenhouse effect have recently stimulated a renewed interest in nuclear energy production, and triggered new studies aimed at developing future generation systems that would address current major safety, proliferation and waste concerns. In particular a possible solution to the waste problem could come from transmutation of the highly radiotoxic nuclear waste in Accelerator Driven Systems or in Generation-IV fast nuclear reactors. The design and operation of the new systems require accurate cross-section data on a large number of isotopes, in particular plutonium, minor actinides, long-lived fission fragments and structural materials. An important contribution to the field is being provided since a few years by a new time of-flight facility operative at CERN, n_TOF. The main features of the neutron beam, in particular the wide energy spectrum, ranging from thermal energy to hundreds of MeV, the very ...
2008-06-01
International Nuclear Information System (INIS)
To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI scanner (Magnetom Avanto, Siemens Medical Solutions) with a ...
A Scheme of 3-D Breakdown-whip Analysis Methodology for High Energy Piping
Energy Technology Data Exchange (ETDEWEB)
High energy piping systems are operated with either or both conditions of maximum operating temperature exceeding 200 .deg. F(93.3 .deg. C) or maximum operating pressure exceeding 275 psig(19.3kg/cm{sup 2}) during normal operating conditions in nuclear power plants. A high energy pipe failure is postulated in branches or piping that runs larger than one inch nominal diameter. The resultant consequences of these postulated pipe breaks must be analyzed for the effect on maintenance of plant safe shutdown capability, containment integrity. And the analyzed results must be applied to the system design so that a pipe failure can not damage essential systems to an extent of impairing design function nor affect necessary component operability. The considerable effects of pipe break are as follows; dynamic effects such as pipe whip, jet impingement and environmental impact by release of system contents. Two types of forces are occurred by the pipe ...
2007-10-15
International Nuclear Information System (INIS)
The cross section database for electron impact excitation and electron impact ionization for hydrogen beam kinetic energies greater than 100 eV was considered, giving for each particular process a reference to a recommended publication of cross sections, as well as the accuracy or estimated accuracy. The work is motivated by the application of neutral beam injection in magnetic confinement devices, such as large tokamaks. 9 refs, 2 figs.
1989-07-01
Estimation of errors provided with dead times of roentgen digital tomography
International Nuclear Information System (INIS)
Impact of apparatus dead time on the accuracy of measurement of radial distribution of the radiation attenuation factor in the roentgen computer tomography for rotation bodies is studied. Analytical expressions are obtained. Calculations of the threshold loads for radiometric detectors, providing for the accuracy of measurement at the stage of designing the tomographic complex detecting unit, are obtained
Understanding the peak asymmetry in alpha liquid scintillation with {beta}/{gamma} discrimination
Energy Technology Data Exchange (ETDEWEB)
The peak evaluation in alpha liquid scintillation is known to be easy, mostly due to the gaussian shape of the peaks. However, we often observed a high-energy tail in addition to a pure gaussian function. This effect is only detectable with a high resolution {alpha} liquid scintillation spectrometer such as the PERALS trademark system. Indeed, its intrinsic resolution (180 keV for a 4 MeV {alpha} particle) is better than that obtained for conventional LSC spectrometers. The peak asymmetry was quantified using the Fisher's coefficient {gamma}{sub 1} (symmetry factor). We show that the main effect responsible for the asymmetry is internal conversion. Indeed, most of the even-even nuclides have low {alpha} intensity transitions leading to excited levels of their daughter nuclides. The internal conversion is almost equal to 100% and consequently produces a sum peak at higher energy. No generalization is possible for odd-even nuclides, but ...
2000-07-01
Synchronized sampling improves fault location
Energy Technology Data Exchange (ETDEWEB)
Transmission line faults must be located accurately to allow maintenance crews to arrive at the scene and repair the faulted section as soon as possible. Rugged terrain and geographical layout cause some sections of power transmission lines to be difficult to reach. In the past, a variety of fault location algorithms were introduced as either an add-on feature in protective relays or stand-alone implementation in fault locators. In both cases, the measurements of current and voltages were taken at one terminal of a transmission line only. Under such conditions, it may become difficult to determine the fault location accurately, since data from other transmission line ends are required for more precise computations. In the absence of data from the other end, existing algorithms have accuracy problems under several circumstances, such as varying switching and loading conditions, fault infeed from the other end, and random value of fault resistance. Most of the ...
1995-04-01
Energy Technology Data Exchange (ETDEWEB)
Research over a three year time span involved the study of multiphase flow useful to understanding the scaleup of coal liquefaction reactors. We attempted to establish the flow patterns and their boundaries in which a direct coal liquefaction, large diameter, bubble column operates. A flow map has been proposed in which coal slurry properties can be input to determine the flow pattern boundaries at reactor operating conditions. Gas holdup and bubble diameters have been measured under different conditions of gas and liquid flow rate. These have been used to determine interfacial area in bubble columns. An equation for the estimation of interfacial area in the bubble-slug flow pattern has been proposed. It has also been established that gas holdup and thus interfacial area depends strongly on the gas distribution in the column. Porous plate gas distributors can yield gas holdups twice as large as sieve plate distributors. Measurements using aqueous solutions (carboxy methyl cellulose) ...
1984-09-01
Simulation of dopant diffusion and activation during flash lamp annealing
International Nuclear Information System (INIS)
A set of advanced models implemented into the simulator Sentaurus Process was applied to simulate ultra shallow junction formation by flash lamp annealing (FLA). The full path transient enhanced diffusion model includes equations for small interstitial clusters (I_2, I_3, I_4), #left brace#3 1 1#right brace# defects and dislocation loops. A dopant-point defect clustering model is used for dopant activation simulation. Several cluster types are considered: B_2, B_2I, B_2I_2, B_3I, B_3I_2, B_3I_3 for boron and As_2, As_2V, As_3, As_3V, As_4, As_4V for arsenic. Different point defect and dopant-point defect pair charge states are taken into account to obtain accurate results in the high doping level region. The flux expressions in the three-phase segregation model include a dependence on the doping level and point defect supersaturation. The FLA process was performed at various peak temperatures in a Mattson Millios"T"M fRTP"T"M system. The measured wafer temperature ...
2008-12-05
Simulation and Observation of Acoustic-Gravity Waves in the Ionosphere
Atmospheric and ionospheric perturbations associated with the acoustic-gravity waves (AGW) with typical frequencies of a few hertz -millihertz are considered. These events may be caused by the influence from space and atmosphere as well as by oscillations of the Earth surface and other near-surface phenomena. The surface sources include long-period oscillations of the Earth's surface, earthquakes, explosions, thermal heating, seisches and tsunami waves. The wavelike phenomena manifest themself as travelling disturbances of air (in the atmosphere) and of electron density (in the ionosphere). Travelling ionospheric disturbances (TIDs) are well detected by radio physical methods. AGW generation by near-surface sources is modeled by the numerical solution of the equation of geophysical fluid dynamics for different sources in two-dimensional non-linear dissipative compressible atmosphere. The numerical calculations are based on the FCT (Flux Corrected Transport) technique of the second ...
2010-01-01
RESEARCH IN ACTIVATION ANALYSIS. Quarterly Progress Report, April-August 1962
The experimental work completed thus far in the areas of rapid radiochemical separations and metastable isomeric states is summarized. Activation analyses were made in samples of ore materials and metals using rapid radiochemical separations to isolate short-lived radioactive isotopes such as 3.77-min V/sup 52/ and 14.6-min Mo/sup 101/. The analytical results obtained were compared to the results obtained from standard chemical and instrumental analytical methods and, where possible, to activation analysis results obtained from longer-lived isotopes of the same element. Further work is in progress to improve the procedures, to evaluate the reproducibility and accuracy of the methods, and to evaluate their usefulness on a wide variety of sample matrices. The research on short-lived metastable isomers showed that 1.7-min W/sup 185m/ is not produced in sufficiently high yield for the development of a supplementary ...
1962-09-19
International Nuclear Information System (INIS)
The International Atomic Energy Agency has initiated a co-ordinated research programme on implementation of base-isolation for nuclear structures. This paper discusses two areas relevant to modelling elastomeric base-isolators. These are the use of simplified models to predict the response of isolated structures to earthquake inputs and finite element analysis for calculating the stress distributions within the isolators. In the former, a curvilinear hysteretic model of the high damping natural rubber able to accommodate the stiffening of the rubber at large shear deflections is presented. Its predictions of structural accelerations and bearing displacement produced by design earthquakes and those above the design level are compared with those using a linear spring and dashpot model. A comparison has been made between two finite element analyses using MARC and ABAQUS of the force-deformation behaviour of a single disc of rubber bonded on both sides. The disc was ...
1996-05-27
Energy Technology Data Exchange (ETDEWEB)
This work presents a study of the {sup 1}P{sup 0} excited states of He that can be reached by absorption of a single photon carrying an energy close to the double ionization threshold (DIT) (79 eV). Above the DIT, these states are the double continuum states; below, they are the double excited states. These two types of states are tightly coupled to the single continuum states with or without excitation of the residual ion He{sup +}, owing to their degeneracy in energy. In a one-photon process, these states can only be formed owing to the electronic correlations in the system which must be well described to obtain quantitative good results. Our study is a part of the work which aims at a united description of all these doubly excited, ionized-excited, and double continuum states. We use the Hyperspherical R-Matrix with Semiclassical Outgoing Waves (HRM-SOW) method, initially dedicated to double photoionization studies. We extend it to extract information on the single continuum. This ...
2007-04-15
Manitoba Hydro long-term high-voltage transmission line magnetic field monitoring project
International Nuclear Information System (INIS)
As part of the licensing process to construct a new 230 kV transmission line on an existing right-of-way in Manitoba, an electrical effects study was conducted in 1998. The study was part of the environmental assessment program crucial in obtaining government approval to construct the line. Some residents living adjacent to the new transmission circuit expressed concerns about alleged adverse health effects associated with long-term exposure to magnetic fields from high voltage transmission lines. In order to verify the accuracy of the predicted magnetic field levels submitted to the regulatory body in the the electrical effects study and to instill confidence in the residents of the affected communities, a three-year magnetic monitoring project was conducted between 2003 and 2005 along the right-of-way after the new 230kV transmission line was energized by Manitoba Hydro. This paper described the monitoring program, with reference to location; ...
2008-10-19
Large sample NAA facility at GRR-1 research reactor: Design and applications
International Nuclear Information System (INIS)
Full text: A Large Sample Neutron Activation Analysis (LSNAA) facility is under development at GRR-1 research reactor, NCSR 'Demokritos'. The LSNAA facility design incorporates sample irradiation in the reactor's graphite thermal neutron column and subsequent measurement of the activity induced at a gamma spectroscopy system with gamma ray transmission measurement options included. Monte Carlo neutron and photon transport code MCNP-4C was used to model the facility. Appropriate correction factors accounting for neutron field perturbation during sample irradiation, high purity germanium detector efficiency for the volume source and gamma ray self-absorption within the sample itself were derived. The results of the computations were experimentally verified by activation foil measurements for a set of known materials and a range of sample sizes extending up to 10 litters. Moreover, the special issue of large sample analysis of non-homogeneous samples is examined and ...
2003-06-09
Energy Technology Data Exchange (ETDEWEB)
The purpose of the project is to further develop a Danish natural gas reformer system including optimisation of subsystems and the overall system consisting of a natural gas reformer and fuel cell CHP generator. This will contribute to the evaluation of to what extend Denmark shall develop small reformer units for PEM fuel Cells. In the project a reformer system with a high degree of automatic control has been build that fulfils the CHP requirements to operation time, dynamics etc. This work, with a FP05 reformer unit, has given valuable results concerning the possibilities and limitations of the reformer technology for CHP usage. It is important that the reformer and fuel cell units are designed with matching yields to optimise efficiency, turn-down start-up time etc. The burner that delivers heat for the steam reaction shall be able to use natural gas as fuel. This gives the possibility of using existing burner technology. In addition this will improve the ...
2006-11-03
International Nuclear Information System (INIS)
Accurate prediction of ribbed duct flow and heat transfer is of importance to the gas turbine industry. The present study comprehensively validates the use of large eddy simulations (LES) for predicting flow and heat transfer with measured flowfield data in a stationary duct with 90"o ribs and elucidates on the detailed physics encountered in the developing flow region, the fully developed region, and the 180"o bend region. Among the major flow features predicted with accuracy are flow transition at the entrance of the duct; the distribution of mean and turbulent quantities in the developing, fully developed, and 180"o bend; the development of secondary flows in the duct cross-section and the 180"o bend; and friction and heat transfer augmentation. At the duct inlet, both the computations and experiments show that the peak turbulence intensities reach values as high as 40% in the streamwise and spanwise directions and 32% in the vertical ...
2006-04-01
Analysis of log rate noise in Ontario's CANDU reactors
Energy Technology Data Exchange (ETDEWEB)
In the fall of 2003, the operators noticed that in the recently-refurbished Bruce A Shutdown System no. 1 (SDS1) the noise level in Log Rate signals were much larger than before. At the request of the Canadian Nuclear Safety Commission (CNSC), all Canadian CANDU reactors took action to characterize their Log Rate noise. Staff of the Inspection and Maintenance Services division of Ontario Power Generation (OPG) has collected high-speed high-accuracy noise data from nearly all 16 Ontario reactors, either as part of routine measurements before planned outages or as a dedicated noise recording. This paper gives the results of examining a suitable subset of this data, with respect to the characteristics and possible causes of Log Rate noise. The reactor and instrumentation design is different at each station: the locations of the moderator injection nozzles, the location of the ion chambers for each system, and the design of the Log Rate amplifiers. ...
2007-07-01
/sup 242/Am/sup m/ fission cross section
Energy Technology Data Exchange (ETDEWEB)
The neutron-induced fission cross section of /sup 242/Am/sup m/ has been measured over the energy region from 10/sup -3/ eV to approx.20 MeV in a series of experiments utilizing a linac-produced ''white'' neutron source and a monoenergetic source of 14.1 MeV neutrons. The cross section was measured relative to that of /sup 235/U in the thermal (0.001 to approx.3 eV) and high energy (1 keV to approx.20 MeV) regions and normalized to the ENDF/B-V /sup 235/U(n,f) evaluated cross section. In the resonance energy region (0.5 eV to 10 keV) the neutron flux was measured using thin lithium glass scintillators and the relative cross section thus obtained was normalized to the thermal energy measurement. This procedure allowed a consistency check between the thermal and high energy data. The cross section data have a statistical accuracy of approx.0.5% at thermal energies and in the 1-MeV energy ...
1984-06-01
Technical note: A physical phantom for assessment of accuracy of deformable alignment algorithms
International Nuclear Information System (INIS)
The purpose of this study was to investigate the feasibility of a simple deformable phantom as a QA tool for testing and validation of deformable image registration algorithms. A diagnostic thoracic imaging phantom with a deformable foam insert was used in this study. Small plastic markers were distributed through the foam to create a lattice with a measurable deformation as the ground truth data for all comparisons. The foam was compressed in the superior-inferior direction using a one-dimensional drive stage pushing a flat 'diaphragm' to create deformations similar to those from inhale and exhale states. Images were acquired at different compressions of the foam and the location of every marker was manually identified on each image volume to establish a known deformation field with a known accuracy. The markers were removed digitally from corresponding images prior to registration. Different image registration algorithms were tested using this method. Repeat ...
2007-07-01
Comparison of NLCD with NWI Classifications of Baldwin and Mobile Counties, Alabama
An assessment of the accuracy of National Land Cover Data 2001 as compared to National Wetlands Inventory mapping of Mobile and Baldwin Counties conducted by the U.S. Geological Survey's (USGS) National Wetlands Research Center (NWRC). Both classifications were checked against stratified randomly selected ground-based sites and with each other to compare the accuracy of the NLCD with NWI classification methods. For this accuracy comparison, numerous visits were made by photointerpreters to the Mobile Bay area to establish signatures for the modified NWI mapping. After all of the quadrangles in Baldwin and Mobile Counties were mapped, an accuracy assessment of those maps was conducted by field-checking the mapped classes with ground-based check sites. These same sites were used to check the accuracy of the NLCD and also as the basis for cross-walking the NLCD and NWI classification ...
2009-01-01
International Nuclear Information System (INIS)
Interest to thin film of metals' silicides first of all is conditioned intrinsic al them unique physical properties. On their basis of it is possible to produce extremely sophisticated devices of solid-state electronics, production which needs the controlled change of physics, chemical and electrical properties with high-level of accuracy. On the present time most are in detail investigated composition, structure and properties of three-dimensional samples of metals' silicides. In the last years the intensive are led to researches in the direction of creation and study of physical-chemical properties thin (500-1000 Angstroms) and ultrafine (100-120 Angstroms) films silicides. It has information about composition, morphology of surface and emission of properties of thin film of silicides of barium, of cobalt and of palladium, was obtained in conditions of ultra-high vacuum. Low energy ion implantation and further annealing ...
British Library Electronic Table of Contents (United Kingdom)
Aim.- To identify what determinants influence the prevalence and accuracy of nursing diagnosis documentation in clinical practice. Background.- Nursing diagnoses guide and direct nursing care. They are the foundation for goal setting and provide the basis for interventions. The literature mentions several factors that influences nurses- documentation of diagnoses, such as a nurse-s level of education, patient-s condition and the ward environment. Design.- Systematic review. Method.- MEDLINE and CINAHL databases were searched using the following headings and keywords: nursing diagnosis, nursing documentation, hospitals, influence, utilisation, quality, implementation and accuracy. The search was limited to articles published between 1995-October 2009. Studies were only selected if they were...
2011-01-01
Extremum-Preserving Limiters for MUSCL and PPM
Limiters are nonlinear hybridization techniques that are used to preserve positivity and monotonicity when numerically solving hyperbolic conservation laws. Unfortunately, the original methods suffer from the truncation-error being first-order accurate at all extrema despite the accuracy of the higher-order method. To remedy this problem, higher-order extensions were proposed that relied on elaborate analytic and geometric constructions. Since extremum-preserving limiters are applied only at extrema, additional computational cost is negligible. Therefore, extremum-preserving limiters ensure higher-order spatial accuracy while maintaining simplicity. This report presents higher-order limiting for (i) computing van Leer slopes and (ii) adjusting parabolic profiles. This limiting preserves monotonicity and accuracy at smooth extrema, maintains stability in the presence of discontinuities and under-resolved gradients, and is ...
2009-01-01
British Library Electronic Table of Contents (United Kingdom)
Statement of problem Titanium is the most biocompatible metal used for dental casting; however, there is concern about its marginal accuracy after porcelain application since this aspect has direct influence on marginal fit. Purpose The purpose of this study was to determine the effect that metal selection and the porcelain firing procedure have on the marginal accuracy of metal ceramic prostheses. Material and methods Cast CP Ti, milled CP Ti, cast Ti-6Al-7Nb, and cast Ni-Cr copings (n=5) were fired with compatible porcelains (Triceram for titanium-based metals and VITA VMK 95 for Ni-Cr alloy). The Ni-Cr alloy fired with its porcelain served as the control. Photographs of metal copings placed on a master die were made. Marginal discrepancy was determined on the photographs using an image ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
During the last years one focus of German PWR safety analysis was boron dilution events with the potential of reactivity transients. Coolant with a low boron concentration could be collected in localized areas of the reactor coolant system e.g. by separation of borated reactor coolant into highly concentrated and diluted fractions (inherent dilution) which can occur during reflux- condenser heat transfer after a small break loss of coolant accident with a limited availability of the emergency core cooling systems. The TUeV NORD SysTec was charged by German supervisory authorities with the assessment of the safety analyses of boron dilution events presented by the utilities. These analyses are based on the simulation of boron dilution and transport processes in conjunction with a number of dedicated experiments. The analyses shall demonstrate that boron dilution events cannot lead to recriticality of the core. Hence the boron concentration at the core inlet has to ...
2005-05-01
Verification of the CFD code FLUENT by post test calculation of the ROCOM experiment T665521
International Nuclear Information System (INIS)
During the last years one focus of German PWR safety analysis was boron dilution events with the potential of reactivity transients. Coolant with a low boron concentration could be collected in localized areas of the reactor coolant system e.g. by separation of borated reactor coolant into highly concentrated and diluted fractions (inherent dilution) which can occur during reflux- condenser heat transfer after a small break loss of coolant accident with a limited availability of the emergency core cooling systems. The TUeV NORD SysTec was charged by German supervisory authorities with the assessment of the safety analyses of boron dilution events presented by the utilities. These analyses are based on the simulation of boron dilution and transport processes in conjunction with a number of dedicated experiments. The analyses shall demonstrate that boron dilution events cannot lead to recriticality of the core. Hence the boron concentration at the core inlet has to ...
2005-05-01
Validation of the CFD code fluent by post-test calculation of a density-driven ROCOM experiment
Energy Technology Data Exchange (ETDEWEB)
During the last years, boron dilution events with the potential of reactivity transients were an important issue of German PWR safety analyses. A coolant with a low-boron concentration could be collected in localized areas of the reactor coolant system, e.g., by separation of a borated reactor coolant into highly concentrated and diluted fractions (inherent dilution) which can occur during reflux-condenser heat transfer after a small break loss of coolant accident with a limited availability of the emergency core cooling systems. During the course of follower core assessments, TUV NORD SysTec appraises safety analyses of boron dilution events presented by the utilities. These analyses are based on the simulation of boron dilution and transport processes in conjunction with a number of dedicated experiments. The analyses demonstrate that boron dilution events cannot lead to recriticality of the core. Hence, the boron concentration at the core inlet has to be ...
2007-09-15
Trajectory generation for car-like robots
Energy Technology Data Exchange (ETDEWEB)
Autonomous robots or remotely operated vehicles have raised high hopes in the military and industrial communities because of the potential safety improvement and gain of productivity they may provide. Waste management on nuclear sites, pallet manipulation in factories, interventions on battle-fields, etc., are actively studied. A lot of these applications require powerful four-wheel vehicles, the kinematics of which is similar to that of a car. Such vehicles have three degrees of freedom: the (x,y) positions in a plane and the orientation of the vehicle. Path planning is often understood as only changing the position of the vehicle, whereas the tasks performed by this kind of robot requires a perfect orientation of the vehicle: forklifting a pallet or docking at a loading or unloading station requires accuracy in the orientation of the vehicle. It is this requirement and the kinematic constraints of the motion mode which have led to the ...
1990-01-01
International Nuclear Information System (INIS)
Available in abstract form only. Full text of publication follows: The uncertainties of decommissioning costs increase high due to several conditions. Decommissioning cost estimation depends on the complexity of nuclear installations, its site-specific physical and radiological inventories. Therefore, the decommissioning costs of nuclear research facilities must be estimated in accordance with the detailed sub-tasks and resources by the tasks of decommissioning activities. By selecting the classified activities and resources, costs are calculated by the items and then the total costs of all decommissioning activities are reshuffled to match with its usage and objectives. And the decommissioning cost of nuclear research facilities is calculated by applying a unit cost factor method on which classification of decommissioning works fitted with the features and specifications of decommissioning objects and establishment of composition factors are based. Decommissioning ...
2007-09-02
Energy Technology Data Exchange (ETDEWEB)
The first study in this dissertation describes the development of a suppressed ion chromatographic (SIC) technique for the direct, simultaneous determination of the As and Se oxyanions in soil solution. Baseline resolution of 1 mg L[sup [minus]1] each of arsenite, arsenate, selenite, and selenate was achieved in the presence of 50 mg L[sup [minus]1] each of F, Cl, NO[sub 3]-N, SO[sub 4]-S, and PO[sub 4]-P. Detection limits ranged from 0.026 mg L[sup [minus]1] for selenite to 0.120 mg L[sup [minus]1] for arsenate. The accuracy of the SIC technique was verified by comparison to spectroscopic methods. The second study investigated the suitability of linear-plateau regression analysis for statistical evaluation of As adsorption data. The time required to reach the adsorption plateau depended on soil characteristics and As species. Identification of the adsorption plateau by the linear-plateau model allowed comparison of adsorption rates and maxima through analysis of ...
1992-01-01
Shawnee flue gas desulfurization computer model users manual
Energy Technology Data Exchange (ETDEWEB)
In conjunction with the US Enviromental Protection Agency sponsored Shawnee test program, Bechtel National, Inc., and the Tennessee Valley Authority jointly developed a computer model capable of projecting preliminary design and economics for lime- and limestone-scrubbing flue gas desulfurization systems. The model is capable of projecting relative economics for spray tower, turbulent contact absorber, and venturi-spray tower scrubbing options. It may be used to project the effect on system design and economics of variations in required SO/sub 2/ removal, scrubber operating parameters (gas velocity, liquid-to-gas (L/G) ration, alkali stoichiometry, liquor hold time in slurry recirculation tanks), reheat temperature, and scrubber bypass. It may also be used to evaluate alternative waste disposal methods or additives (MgO or adipic acid) on costs for the selected process. Although the model is not intended to project the economics of an individual system to a high ...
1985-03-01
International Nuclear Information System (INIS)
This paper describes a semi-empirical calculation of the air-broadened half-widths and the air pressure-induced frequency shifts for the H_2"1"6O isotopologue. This semi-empirical calculation is based on fits of several recent high-quality measurements and theoretical calculations to the first-order terms in the expansion of the complex Robert-Bonamy (CRB) equations, which yields a second- and first-order polynomial function of the differences in the upper- and lower-state vibrational quantum numbers for the half-width and line shift, respectively. The aim of this work was to obtain a complete set of air-broadened half-widths and air pressure-induced frequency shifts for transitions of H_2"1"6O present in the HITRAN database from microwave to the visible in order to supplement the observed and calculated values. For around 700 sets of rotational quantum numbers (J"'K_a"'K_c"'<-J"''K_a"''K_c"''), semi-empirical coefficients describing the vibrational dependence ...
2005-12-01
Optimizing an analytical dose calculation algorithm for fast 2D calculations
International Nuclear Information System (INIS)
Previously, an analytical dose calculation algorithm for MLC-based radiotherapy was developed and commissioned, which includes a detailed model of various MLC effects as a unique feature [1]. The algorithm was originally developed as an independent verification of the treatment planning system's dose calculation and it explicitly modeled spatial and depth dependent MLC effects such as interleaf transmission, the tongue-and-groove effect, rounded leaf ends, MLC scatter, beam hardening, and gradual MLC transmission fall-off with increasing off-axis distance. Originally the algorithm was implemented in Mathematica trademark (Wolfram). To speed up the calculation time and to be able to calculate high resolution 2D dose distributions within a reasonable time frame (<2 s) the algorithm needs to be optimized and to be embedded in a user friendly environment. To achieve this goal, the dose calculation model is implemented in Visual Basic 6.0, which decreases the ...
NPOESS Interface Data Processing Segment (IDPS) Hardware
The National Oceanic and Atmospheric Administration (NOAA), Department of Defense (DoD), and National Aeronautics and Space Administration (NASA) are jointly acquiring the next-generation weather and environmental satellite system; the National Polar-orbiting Operational Environmental Satellite System (NPOESS). NPOESS replaces the current Polar-orbiting Operational Environmental Satellites (POES) managed by NOAA and the Defense Meteorological Satellite Program (DMSP) managed by the DoD. The NPOESS satellites carry a suite of sensors that collect meteorological, oceanographic, climatological, and solar-geophysical observations of the earth, atmosphere, and space. The NPOESS design allows centralized mission management and delivers high quality environmental products to military, civil and scientific users. The ground data processing segment for NPOESS is the Interface Data Processing Segment (IDPS), developed by Raytheon Intelligence and Information Systems. IDPS ...
2008-12-01
International Nuclear Information System (INIS)
In the present paper a procedure is proposed for the determination of traces of Cd, Co, Mn and Cr in petroleum industry produced water by inductively coupled plasma optical emission spectrometry. The procedure is based on cloud point extraction of these metals, as their dithizonate complexes, into the surfactant-rich phase of octylphenoxypolyethoxyethanol surfactant (Triton X-114). Extractions were carried out in solutions with salinities between 10 per mille and 70 per mille. Since residual salinity in the surfactant-rich phase caused differences in its transport to the plasma, yttrium was used as an internal standard to correct for this effect. The simultaneous metal extraction procedure was optimized by response surface methodology using a Doehlert design and desirability function. Enhancement factors of 21, 21, 9 and 19, along with limits of quantification of 0.093, 0.20, 0.73 and 1.2 #mu#g L"-"1, and precision expressed as relative standard deviation (n = 8, 20.0 #mu#g L"-"1) of ...
2007-09-01
Energy Technology Data Exchange (ETDEWEB)
A feasibility study test and 3 field trials were performed at Darlington NGS in 1996, 1999 and 2000 on ABB LP turbines. The scope of these trials was to commission in-situ automatic phased array systems capable to inspect blade roots and rotor steeples of L-0 and L-1 rows. GE disk-blade rim attachments were inspected at Bruce B nuclear station, in fall of 1999. The automated ultrasonic phased array technology is capable of high-speed rate and reliable detection and sizing. The capability demonstration was performed on mock-ups and reference blocks, using EDM notches. A custom built UT simulation software: Imagine 3D interfaces with SimScan to generates the spreadsheets/charts with target and probe coordinates and ultrasonic path and angles (refracted and skew) to hit the reference target. Examination of L-0 blade and rotor steeple grooves was performed with 2 phased array systems under networking. Data analysis was done in near-real time. Manual and automatic ...
2000-07-01
Higgs particles in the standard model and supersymmetric theories
International Nuclear Information System (INIS)
This thesis presents a theoretical analysis of the properties of the Higgs bosons in the standard model (SM) and the minimal supersymmetric extension (MSSM), which can be investigated at the LHC and e"+e"- linear colliders. The final goal is the reconstruction of the Higgs potential and thus the verification of the Higgs mechanism. MSSM Higgs boson production processes at future #gamma##gamma# colliders are calculated in several decay channels. Heavy scalar and pseudoscalar Higgs bosons can be discovered in the bb final state in the investigated mass range 200 to 800 GeV for moderate and large values of tan#beta#. The #tau#"+#tau#"- channel provides a heavy Higgs boson discovery potential for large values of tan#beta#. Several mechanisms that can be exploited at e"+e"- linear colliders for the measurement of the lifetime of a SM Higgs boson in the intermediate mass range are analysed. In the WW mode, the lifetime of Higgs scalars with masses below #propor to#160 GeV can be determined ...
GOCE, Satellite Gravimetry and Antarctic Mass Transports
In 2009 the European Space Agency satellite mission GOCE (Gravity Field and Steady-State Ocean Circulation Explorer) was launched. Its objectives are the precise and detailed determination of the Earth's gravity field and geoid. Its core instrument, a three axis gravitational gradiometer, measures the gravity gradient components V xx , V yy , V zz and V xz (second-order derivatives of the gravity potential V) with high precision and V xy , V yz with low precision, all in the instrument reference frame. The long wavelength gravity field is recovered from the orbit, measured by GPS (Global Positioning System). Characteristic elements of the mission are precise star tracking, a Sun-synchronous and very low (260 km) orbit, angular control by magnetic torquing and an extremely stiff and thermally stable instrument environment. GOCE is complementary to GRACE (Gravity Recovery and Climate Experiment), another satellite gravity mission, launched in 2002. While ...
2011-03-01
Energy Technology Data Exchange (ETDEWEB)
The R and D were carried out of a detecting system for measurement of data on the bottom of geothermal well, data transmission and signal processing, and an analysis system for well drilling trajectory control and well assessment while geothermal well drilling based on the data obtained by the detecting system. The paper reported the results of the technology development in fiscal 1996. In the development of the detecting system, improvement/design were conducted on a mud pulse generator constituting sonde, well bottom signal processing equipment, mode switch and inclined information sensor, and the system equivalent to the actual one was manufactured to conduct a running test at high temperature/pressure. Moreover, a test to confirm heat resistance of electronic parts was made for further improvement in heat resistance of the sonde, in order to obtain the data. In the development of an analysis system, conducted were enhancement of operability of the ...
1997-03-01
A marine propulsion system is a very complicated system composed of many mechanical components. As a result, the vibration signal of a gearbox in the system is strongly coupled with the vibration signatures of other components including a diesel engine and main shaft. It is therefore imperative to assess the coupling effect on diagnostic reliability in the process of gear fault diagnosis. For this reason, a fault detection and diagnosis method based on bispectrum analysis and artificial neural networks (ANNs) was proposed for the gearbox with consideration given to the impact of the other components in marine propulsion systems. To monitor the gear conditions, the bispectrum analysis was first employed to detect gear faults. The amplitude-frequency plots containing gear characteristic signals were then attained based on the bispectrum technique, which could be regarded as an index actualizing forepart gear faults diagnosis. Both the back propagation neural network (BPNN) and the ...
2011-03-01
Energy Technology Data Exchange (ETDEWEB)
There is renewed interest in the development of natural gas vehicles in response to the challenge to reduce urban air pollution and consumption of petroleum. The natural gas/diesel dual fuel engine is one way to apply natural gas to the conventional diesel engine. Dual fuel engines operating on natural gas and diesel emit less nitrogen oxides, and less carbon soot to the air compared to conventional diesel engines. The problem is that at light loads, fuel efficiency is reduced and emissions of hydrocarbons and carbon monoxide are increased. This thesis focused on control methods for emissions of hydrocarbons and carbon monoxide in the dual fuel engine at light loads. This was done by developing a reverse flow catalytic converter to complement dual fuel engine exhaust characteristics. Experimental measurements and numerical simulations of reverse flow catalytic converters were conducted. Reverse flow creates a high reactor temperature even when the engine is run at ...
2000-07-01
Excitation function of "5"9 Co (n, 2n) "5"8 Co process in the energy range 13.9-14.7 MeV
International Nuclear Information System (INIS)
The objective of the study is to measure the neutron cross sections for the "5"9 Co (n, 2n) "5"8 Co reaction around the 14 MeV energy region. Neutron activation cross section for almost all the nuclei, mostly in the medium energy region e.g., 7 to 20 MeV are reported in literature. Neutron cross section data around 14 MeV is of immense importance for the design of D + T fusion reactors. The accuracy of the cross section data at this energy region is a requirement for correct prediction of reactor parameters e.g., tritium breeding, nuclear heating, induced activity, etc. In order to perform the experiment, the Co-sample sandwiched in Ni foils was irradiated employing the J-25 Neutron Generator at the AERE, Savar, Dhaka. After irradiation, the counting was done by the activation technique using a high resolution Hp Ge gamma ray spectrometer. The gamma ray spectra was analyzed in a Canberra series-40 Multi-channel Analyzer. Calculations for cross ...
Energy Technology Data Exchange (ETDEWEB)
In the past, Condition Monitoring Systems (CMS) still showed weaknesses during the employment in the damage diagnosis and/or early failure detection of damages of roller bearings in transmissions of wind power plants. This is not only due to the insufficient consideration of the variable frequency of the wind power plants during the internal processing. The presently used methods of analysis result from the communication technology and are used successfully for years at frequency solid systems. Usually, only too few information are at the disposal to the supplier of CMS in order to parametrize their systems on the respective application particularly. An exact knowledge of the internal structure of the object to be diagnosed is compellingly necessary for a successful diagnosis so that a loadable statement based on the acquired measuring data base becomes possible. Furthermore, one must clarify the borders of the presently used systems. The theory of these systems is based on an impact ...
2010-07-01
Development of a neutron/. gamma. ray radiation monitor
Energy Technology Data Exchange (ETDEWEB)
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/..gamma.. ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time ..gamma.. spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded ..gamma.. spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations using a linearized ...
1983-01-01
Development of a neutron/#gamma# ray radiation monitor
International Nuclear Information System (INIS)
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/#gamma# ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time #gamma# spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded #gamma# spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations using a linearized ...
1983-01-01
Development of a Neutron/gamma Ray Radiation Monitor.
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/gamma ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time gamma spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded gamma spectra created by the photopeak-compton edge combination in the plateau portion of the knee response, correcting equations using a linearized approximation ...
1983-01-01
Energy Technology Data Exchange (ETDEWEB)
As characterization of artificial cracks formed underground by using the water pressure fracturing method, experiments have been carried out to detect relationship of pressurization and S-wave propagation time with the polarizing direction dependence. Openings are created when pressure in the vicinity of the artificial cracks increases greater than reopening pressure of micro cracks. Elastic wave velocity decreases in this region because of water in the opened micro cracks. Anisotropy is created in the S-wave propagation velocity due to influence from anisotropic reopening region when the artificial cracks are pressurized, and is separated into two components which polarize orthogonally with each other (micro splitting). Field experiments conducted at the Higashi-hachimantai field were analyzed by using wavelet transform. It was possible to detect the S-wave arrival time at high accuracy, and the arrival of an orthogonally polarized wave was ...
1997-05-27
Energy Technology Data Exchange (ETDEWEB)
The two tank (125,000kl each) foundations under construction are as large as 85m in diameter, and the north-side tank is to be placed over a sharper slope. The tanks are greatly different in their height from the rockbed since they are to be placed at the same level. For reduction in construction cost and time, a pile foundation design is chosen as the basic concept for foundation construction. After an overall evaluation of stability upon exposure to seismic torsion and of the deformation characteristics of piles and concrete slabs, a total pile foundation design with rock debris replaced with crushed rock is determined to be the design to be adopted. Since the piles to be driven in are greatly different in length, error in the pile supporting force will be too grave under the conventional pile landing control system. Therefore, a high-accuracy pile landing control system is employed, established after a rapid load test in addition to the dynamic load test for the ...
1998-09-05
Chapter 14: Seismic imaging using 2- and 3-D migration
Energy Technology Data Exchange (ETDEWEB)
Development of a number of original 3-D migration methods and algorithms is described. The computational efficiency of these algorithms is demonstrated by implementing them on vector and parallel supercomputers. Two-dimensional post-stack and pre-stack depth migration algorithms in the frequency - space domain using implicit finite difference method were also developed and implemented on a parallel computer, and adapted for applications that range from deep crustal imaging of seismic wavefields that involve wide ranging travel times and frequencies. All implicit finite difference migration algorithms were highly prallelized . The one pass 3-D post-stack depth migration algorithm was extensively used for imaging of seismic monitoring data from Cold Lake, Alberta. Experience shows that it provides the right trade-off between accuracy and computational efficiency. A new formulation of the 3-D reverse-time migration method was developed using ...
1999-09-01
Energy Technology Data Exchange (ETDEWEB)
To establish the optimum barium-based reduced-laxative tagging regimen prior to CT colonography (CTC). Ninety-five subjects underwent reduced-laxative (13 g senna/18 g magnesium citrate) CTC prior to same-day colonoscopy and were randomised to one of four tagging regimens using 20 ml 40%w/v barium sulphate: regimen A: four doses, B: three doses, C: three doses plus 220 ml 2.1% barium sulphate, or D: three doses plus 15 ml diatriazoate megluamine. Patient experience was assessed immediately after CTC and 1 week later. Two radiologists graded residual stool (1: none/scattered to 4: >50% circumference) and tagging efficacy for stool (1: untagged to 5: 100% tagged) and fluid (1: untagged, 2: layered, 3: tagged), noting the HU of tagged fluid. Preparation was good (76-94% segments graded 1), although best for regimen D (P = 0.02). Across all regimens, stool tagging quality was high (mean 3.7-4.5) and not significantly different among regimens. The HU of layered ...
2008-01-15
Energy Technology Data Exchange (ETDEWEB)
This paper presented a technique to compensate for distorted secondary currents. Since current distortion can cause operating time delays in protective relays, attempts are made to minimize current transformer (CT) saturation by choosing a CT with a voltage rating that is at least twice that required for the maximum steady-state symmetrical fault current. However, the possibility of saturation still exists because of the DC component of an asymmetrical fault current and the remanent flux in a CT core. An advanced algorithm for the compensation of the distorted signal due to CT saturation was proposed. The secondary current can be expressed as the linear combination of sinusoidal and exponential signals, if no saturation occurs. In this study, the algorithm first utilized the third difference function for detecting the start and end of saturation in real-time. The AR model-based FIR filter and the least mean square curve fitting method were then used to estimate the exponential ...
2006-07-01
Assessment of trace element contents of chicken products from turkey
Energy Technology Data Exchange (ETDEWEB)
Due to the consumption of chicken and chicken products in Turkey at high ratio, trace metal content of chicken and chicken products from Turkey were determined by atomic absorption spectrometry after microwave digestion. The accuracy of the method was confirmed by analysis of standard reference material (NIST SRM 1577b Bovine liver). Trace element content in various parts of chicken samples and chicken products were to be in the range of 0.10-114 {mu}g/g for copper, 0.25-6.09 {mu}g/kg for cadmium, 0.01-0.40 {mu}g/g for lead, 0.10-0.91 {mu}g/g for selenium, 0.05-3.91 {mu}g/g for manganese, 0.06-0.10 {mu}g/g for arsenic, 0.01-0.72 {mu}g/g for chromium, 0.01-2.08 {mu}g/g for nickel, 0.01-0.02 {mu}g/g for cobalt, 0.10-1.90 {mu}g/g for aluminium, 1.21-24.3 {mu}g/g for zinc, 2.91-155 {mu}g/g for iron. The levels of lead in some analyzed chicken products were higher than the recommended legal limits for human consumption.
2009-04-30
An evaluation of current methods of diagnosing colorectal cancer in the United Kingdom
Energy Technology Data Exchange (ETDEWEB)
Colorectal cancer (CRC) is a highly conversed topic, particularly since implementation of screening for CRC is imminent within the U.K. Aims: The aim of this research project was to examine the diagnostic tools currently used within the UK to detect CRC and their impact on the aetiology and epidemiology of CRC. Methodology: The complexity of the research topic lent itself towards a literature review. A systematic approach of researching was therefore adopted to analyse and critically evaluate the reliability and validity of articles. Electronic databases including AMED, Cancerlit, CINHAL, the Cochrane Library, EMBASE, MEDLINE and EBM-Reviews were utilised to provide a wide spectrum of recent and relevant articles. Other research strategies involved looking for books relating to the topics, which were kept to within 6 years of publication to maintain accuracy of information. Selected websites, such as NICE, the Department of Health, NHS websites ...
2009-05-15
Advanced Method for In-Field Measurement, Monitoring and Verification of Total Soil Carbon
The Earth`s oceans, forests, agricultural lands and other natural areas absorb about half of the carbon dioxide emitted from anthropogenic sources. Terrestrial carbon sequestration strategies are immediately available to bridge the gap between current terrestrial sequestration capacity and high-capacity geologic sequestration projects available in 10 to 20 years. Terrestrial carbon sequestration strategies consist of implementing land management practices aimed at decreasing CO2 emitted into the atmosphere and developing advanced measurement tools to inventory and monitor carbon processes in soils and biota. In addition to atmospheric CO2 mitigation and carbon trading advantages, terrestrial carbon sequestration produces a variety of benefits which include reclamation of degraded lands, increased soil productivity, increased land value and a more secure food source. Carbon storage in soil depends on climate and management practices, with potential yearly ...
2005-12-01
A study of neutron room scattering at RPCF
International Nuclear Information System (INIS)
High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers dosimeters use CR39 for neutron detection, which are sent to an ...
1997-01-05
A study of neutron room scattering at RPCF
Energy Technology Data Exchange (ETDEWEB)
High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers dosimeters use CR39 for neutron detection, which are sent to an ...
1996-09-01
A novel method to characterize the MTF in 3D for computed mammotomography
A novel phantom has been developed to measure the modulation transfer function (MTF) in 3D for x-ray computed tomography. The phantom consists of three tungsten wires, positioned nearly orthogonal to each other. Simultaneous measurements of the MTF are taken at various locations along the three orthogonal reconstructed planes. Our computed mammotomography (CmT) system uses a Varian Paxscan 2520 digital x-ray detector which can be positioned anywhere in ~2pi steradian band and can have arbitrary trajectories. With a half-cone beam geometry and with the phantom positioned near the center of rotation, projection images are acquired over 360 degrees. Various 3D orbits are evaluated including vertical axis of rotation and saddle. Reconstructions were performed using an iterative ordered-subsets transmission algorithm on rebinned projection images, using various numbers of iterations. Rotation of reconstructed slices isolated each wire into its own plane. At various locations along the ...
2006-03-01
Energy Technology Data Exchange (ETDEWEB)
Detailed chemical kinetic reaction mechanisms have been developed to describe the pyrolysis and oxidation of the n-alkanes, including n-octane (n-C{sub 8}H{sub 18}), n-nonane (n-C{sub 9}H{sub 20}), n-decane (n-C{sub 10}H{sub 22}), n-undecane (n-C{sub 11}H{sub 24}), n-dodecane (n-C{sub 12}H{sub 26}), n-tridecane (n-C{sub 13}H{sub 28}), n-tetradecane (n-C{sub 14}H{sub 30}), n-pentadecane (n-C{sub 15}H{sub 32}), and n-hexadecane (n-C{sub 16}H{sub 34}). These mechanisms include both high temperature and low temperature reaction pathways. The mechanisms are based on previous mechanisms for n-heptane, using the same reaction class mechanism construction developed initially for n-heptane. Individual reaction class rules are as simple as possible in order to focus on the parallelism between all of the n-alkane fuels included in the mechanisms, and there is an intent to develop these mechanisms further in the future to incorporate greater levels of ...
2007-09-25
Energy Technology Data Exchange (ETDEWEB)
Detailed chemical kinetic reaction mechanisms have been developed to describe the pyrolysis and oxidation of nine n-alkanes larger than n-heptane, including n-octane (n-C{sub 8}H{sub 18}), n-nonane (n-C{sub 9}H{sub 20}), n-decane (n-C{sub 10}H{sub 22}), n-undecane (n-C{sub 11}H{sub 24}), n-dodecane (n-C{sub 12}H{sub 26}), n-tridecane (n-C{sub 13}H{sub 28}), n-tetradecane (n-C{sub 14}H{sub 30}), n-pentadecane (n-C{sub 15}H{sub 32}), and n-hexadecane (n-C{sub 16}H{sub 34}). These mechanisms include both high temperature and low temperature reaction pathways. The mechanisms are based on our previous mechanisms for the primary reference fuels n-heptane and iso-octane, using the reaction class mechanism construction first developed for n-heptane. Individual reaction class rules are as simple as possible in order to focus on the parallelism between all of the n-alkane fuels included in the mechanisms, and these mechanisms will be refined further in the future to ...
2008-02-08
Development of fire simulation models for radiative heat transfer and probabilistic risk assessment
Energy Technology Data Exchange (ETDEWEB)
An essential part of fire risk assessment is the analysis of fire hazards and fire propagation. In this work, models and tools for two different aspects of numerical fire simulation have been developed. The primary objectives have been firstly to investigate the possibility of exploiting state-of-the-art fire models within probabilistic fire risk assessments and secondly to develop a computationally efficient solver of thermal radiation for the Fire Dynamics Simulator (FDS) code. In the first part of the work, an engineering tool for probabilistic fire risk assessment has been developed. The tool can be used to perform Monte Carlo simulations of fires and is called the Probabilistic Fire Simulator (PFS). In Monte Carlo simulation, the simulations are repeated multiple times, covering the whole range of variability of the input parameters and thus resulting in a distribution of results covering what can be expected in reality. In practical applications, advanced simulation techniques ...
2008-07-01
International Nuclear Information System (INIS)
The accuracy of dose computation within the lungs depends strongly on the performance of the calculation algorithm in regions of electronic disequilibrium that arise near tissue inhomogeneities with large density variations. There is a lack of data evaluating the performance of highly developed analytical dose calculation algorithms compared to Monte Carlo computations in a clinical setting. We compared full Monte Carlo calculations (performed by our Monte Carlo dose engine MCDE) with two different commercial convolution/superposition (CS) implementations (Pinnacle-CS and Helax-TMS's collapsed cone model Helax-CC) and one pencil beam algorithm (Helax-TMS's pencil beam model Helax-PB) for 10 intensity modulated radiation therapy (IMRT) lung cancer patients. Treatment plans were created for two photon beam qualities (6 and 18 MV). For each dose calculation algorithm, patient, and beam quality, the following set of clinically relevant dose-volume ...
2006-09-01
Contaminant transport in fracture networks with heterogeneous rock matrices. The Picnic code
Energy Technology Data Exchange (ETDEWEB)
In the context of safety assessment of radioactive waste repositories, complex radionuclide transport models covering key safety-relevant processes play a major role. In recent Swiss safety assessments, such as Kristallin-I, an important drawback was the limitation in geosphere modelling capability to account for geosphere heterogeneities. In marked contrast to this limitation in modelling capabilities, great effort has been put into investigating the heterogeneity of the geosphere as it impacts on hydrology. Structural geological methods have been used to look at the geometry of the flow paths on a small scale and the diffusion and sorption properties of different rock materials have been investigated. This huge amount of information could however be only partially applied in geosphere transport modelling. To make use of these investigations the 'PICNIC project' was established as a joint cooperation of PSI/Nagra and QuantiSci to provide a new geosphere transport ...
2001-02-01
Verification of MLC based real-time tumor tracking using an electronic portal imaging device
UK PubMed Central (United Kingdom)
Purpose: The authors have developed a novel technique using an electronic portal imaging device (EPID) to verify the geometrical accuracy of delivery of dose-rate-regulated tracking (DRRT)....Full Text Available
2010-06-01
The ten questions screen for childhood disabilities: its uses and limitations in Pakistan.
UK PubMed Central (United Kingdom)
OBJECTIVE--To assess the accuracy of the ten questions screen as a measure of childhood disability for epidemiologic studies in populations lacking resources for professional assessment of children's...Full Text Available
1995-08-01
The Characterisation of Three Types of Genes that Overlie Copy Number Variable Regions
UK PubMed Central (United Kingdom)
BackgroundDue to the increased accuracy of Copy Number Variable region (CNV) break point mapping, it is now possible to say with a reasonable degree of confidence whether a gene...Full Text Available
Spinous process palpation using the scapular tip as a landmark vs a radiographic criterion standard
UK PubMed Central (United Kingdom)
AbstractObjectiveThis study aimed at determining the standing spinal landmark that corresponds to the inferior tip of the scapula and determining the accuracy of experienced...Full Text Available
2007-01-01
Range accuracy in carbon ion treatment planning based on CT-calibration with real tissue samples
UK PubMed Central (United Kingdom)
BackgroundThe precision in carbon ion radiotherapy depends on the calibration of Hounsfield units (HU) as measured with computed tomography (CT) to water equivalence. This calibration...Full Text Available
Radionuclide imaging of the acutely painful scrotum
International Nuclear Information System (INIS)
This paper discusses the clinical application and main objective of testicular imaging. The authors present cases that represent a spectrum of the abnormalities which might be detected by testicular imaging, with special attention given to testicular torsion and the acute diseases which may mimic it clinically. Accuracy of the test is noted.
UK PubMed Central (United Kingdom)
Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. One key component of 4D radiotherapy planning...Full Text Available
2008-04-01
Protein expression based multimarker analysis of breast cancer samples
UK PubMed Central (United Kingdom)
BackgroundTissue microarray (TMA) data are commonly used to validate the prognostic accuracy of tumor markers. For example, breast cancer TMA data have led to the identification...Full Text Available
Object Repetition Leads to Local Increases in the Temporal Coordination of Neural Responses
UK PubMed Central (United Kingdom)
Experience with visual objects leads to later improvements in identification speed and accuracy (“repetition priming”), but generally leads to reductions in neural activity in single-cell...Full Text Available
Neutron data requirements for calculating transactinide isotope build-up in reactors
International Nuclear Information System (INIS)
Based on a generalized theory of perturbations and on non-linear programming an approach to the quantitative determination of necessary accuracies for nuclear data is described. It is used to calculate transactinide isotope build-up in reactors.
1979-08-01
UK PubMed Central (United Kingdom)
The reference medium for brachytherapy dose measurements is water. Accuracy of dose measurements of brachytherapy sources is critically dependent on precise measurement of the source–detector...Full Text Available
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
Using the Klein-Gordon equation with a box potential, a mass formula describing the family of nonflavored meson states with I = 1 is derived. The energy levels calculated agree with those observed within an accuracy of approx. 5%. In the model discussed quarks behave like tachyons.
1987-12-01
Investigation of anomalous CXR response of filled cables
Energy Technology Data Exchange (ETDEWEB)
An anomaly in the continuous X-ray (CXR) response of filled cables is described. A systematic investigation of this anomaly is pursued with a single cable type and a model explaining the anomaly is presented. The effect of the anomaly on the accuracy of CXR measurement of SGEMP response is discussed.
1982-12-01
UK PubMed Central (United Kingdom)
Understanding the dynamics of porcine reproductive and respiratory syndrome virus (PRRSV) vertical transmission is important to enhance the accuracy of monitoring protocols for endemically infected...Full Text Available
2009-10-01
UK PubMed Central (United Kingdom)
The use of dideoxynucleotide triphosphates labeled with different fluorescent dyes (dye terminators) is the most versatile method for automated DNA sequencing. However, variation in peak heights reduces...Full Text Available
1999-06-01
Impalpable Testis and Laparoscopy: When the Gonad Is Not Visualized
UK PubMed Central (United Kingdom)
The diagnostic accuracy of laparoscopy for impalpable testis is well recognized. However, in some cases, laparoscopic findings may be misleading, and a viable gonad may be missed with significant medico-legal...Full Text Available
2004-01-01
Gun Barrel Vibration Absorber to Increase Accuracy
Page 1. Page 2. Page 3. Page 4. Page 5. Page 6. Page 7. Page 8. Page 9. Page 10. Page 11. Page 12. Page 13. Page 14. Page 15. Page 16. Page ...
2002-02-01
Fetal, perinatal, and infant death with congenital renal anomaly
UK PubMed Central (United Kingdom)
Aims: To ascertain why 19.6% of pregnancies in which a fetal renal anomaly has been detected fail to produce a surviving child, and whether antenatal diagnostic accuracy has altered since...Full Text Available
2002-08-01
UK PubMed Central (United Kingdom)
The Electronic REference To access In vivo Concentrations (ERETIC) method was applied to 1H HR-MAS spectroscopy. The accuracy, precision, and stability of ERETIC as a quantitative...Full Text Available
2009-03-01
UK PubMed Central (United Kingdom)
Broth disk elution procedures represent one of the most practical means for clinical laboratories to perform routine antibiotic susceptibility tests on anaerobic bacteria. The accuracy of five disk...Full Text Available
1986-03-01
Direct filtration for recovery of Schistosoma mansoni cercariae in the field
UK PubMed Central (United Kingdom)
The recovery of schistosome cercariae from natural waters has been limited by variations in turbidity and in the accuracy of recovery with different techniques. A modification of the Rowan vacuum paper...Full Text Available
1973-01-01
International Nuclear Information System (INIS)
To evaluate the diagnostic accuracy, complications, and therapeutic impact of CT-guided percutaneous core biopsies of pulmonary lesions. Material and methods: Seventy-nine patients underwent diagnostic CT-guided percutaneous core biopsies of pulmonary lesions between July 1995 and March 1999. Evaluation included corresponding clinical data, pathologic results, and therapeutic consequences. Results: There were 29 benign and 50 malignant lesions. Percutaneous core biopsy had an overall diagnostic accuracy of 95%. For malignant lesions, core biopsy was positive in 48 patients (sensitivity 96%), and for benign lesions, in 27 (sensitivity 93%). There were no false-positive findings. Pneumothoraces were observed in 19 patients (24%) and 4 of them required a chest drain (5%). There were no hematothoraces or major bleeding complications; however, postinterventional local hemorrhages were observed in 23 patients (29%). No hemoptysis was noted. ...
2001-03-01
CT evaulation of thoracic and abdominal fatty masses
International Nuclear Information System (INIS)
The diagnostic accuracy of computed tomography (CT) in several patterns of thoracic and abdominal fatty masses, has been examined. In selected cases our findings overlap the features of the recent literature. The possibility of surgical therapy in peculiar cases of adipose deposits, commonly esteemed benign, is considered.
1986-01-01
CERES BDS Quality Summaries - Atmospheric Science Data Center - NASA
Nov 18, 2010 ... Roughly speaking, the fidelity interval we quote is a "3 sigma" value. ... surface of the foremost quartz filter which is then chemically altered by ... ( CERES) scanner point accuracy using a coastline detection system", ...
UK PubMed Central (United Kingdom)
BackgroundMolecular docking methods are commonly used for predicting binding modes and energies of ligands to proteins. For accurate complex geometry and binding energy estimation,...Full Text Available
UK PubMed Central (United Kingdom)
Several efforts have been made to completely automate cephalometric analysis by automatic landmark search. However, accuracy obtained was worse than manual identification in every study. The analogue-to-digital...Full Text Available
2009-01-01
Adaptive Gun Barrel Vibration Absorber.
Gun barrel vibrations lead to dispersion in the shot patterns. Thus, reducing these vibrations should lead to increased accuracy. Since the muzzle is the anti-node for all vibration modes and its vibrations have the greatest effect on shot dispersion, it ...
2002-01-01
Accuracy of Contacts Calculated from 3D Images of Occlusal Surfaces
UK PubMed Central (United Kingdom)
ObjectiveCompare occlusal contacts calculated from 3D virtual models created from clinical records to contacts identified clinically using shimstock and transillumination.Full Text Available
2007-06-01
UK PubMed Central (United Kingdom)
BackgroundThis in vitro study was conducted to compare the accuracy of two digital image receptors in identifying the location of tip of a fine endodontic file and radiographic apex...Full Text Available
2010-11-01
Energy Technology Data Exchange (ETDEWEB)
Intracapsular femoral neck fractures remain unsolved fractures even after improvement in techniques of diagnosis and internal fixation. Individuals who sustain displaced femoral neck fractures are at high risk of developing avascular necrosis and non-union. Although several methods for predicting the viability of femoral head have been reported, they are not effective or widely used because of unreliability, potential complications and technical difficulties. Dynamic MRI was introduced in the recent past as a simple, non-invasive technique to predict the femoral head viability after the femoral neck fractures. In this study role of dynamic MRI was studied in 30 patients with 31 intracapsular femoral neck fractures. Fractures were divided in to three types according to dynamic curve patterns on MRI evaluation and were followed up for 6 months to 2 years to observe the final outcome. Sensitivity, Specificity and the Accuracy of dynamic MRI in ...
2010-09-15
International Nuclear Information System (INIS)
Intracapsular femoral neck fractures remain unsolved fractures even after improvement in techniques of diagnosis and internal fixation. Individuals who sustain displaced femoral neck fractures are at high risk of developing avascular necrosis and non-union. Although several methods for predicting the viability of femoral head have been reported, they are not effective or widely used because of unreliability, potential complications and technical difficulties. Dynamic MRI was introduced in the recent past as a simple, non-invasive technique to predict the femoral head viability after the femoral neck fractures. In this study role of dynamic MRI was studied in 30 patients with 31 intracapsular femoral neck fractures. Fractures were divided in to three types according to dynamic curve patterns on MRI evaluation and were followed up for 6 months to 2 years to observe the final outcome. Sensitivity, Specificity and the Accuracy of dynamic MRI in ...
2010-09-01
Energy Technology Data Exchange (ETDEWEB)
The radionuclide characteristics of light-water-reactor (LWR) spent fuel play key roles in the design and licensing activities for radioactive waste transportation systems, interim storage facilities, and the final repository site. Several areas of analysis require detailed information concerning the time-dependent behavior of radioactive nuclides including (1) neutron/gamma-ray sources for shielding studies, (2) fissile/absorber concentrations for criticality safety determinations, (3) residual decay heat predictions for thermal considerations, and (4) curie and/or radiological toxicity levels for materials assumed to be released into the ground/environment after long periods of time. The crucial nature of the radionuclide predictions over both short and long periods of time has resulted in an increased emphasis on thorough validation for radionuclide generation/depletion codes. Current radionuclide generation/depletion codes have the capability to follow the evolution of some 1600 ...
1995-01-01
Energy Technology Data Exchange (ETDEWEB)
Background: The difficulty of directly measuring cellular dose is a significant obstacle to application of target tissue dosimetry for nanoparticle and microparticle toxicity assessment. As a consequence, the target tissue paradigm for dosimetry and hazard assessment of nanoparticles has largely been ignored in favor of using metrics of exposure (e.g. ?g particle/mL culture medium, particle surface area/mL, particle number/mL). We have developed a computational model of solution particokinetics (sedimentation, diffusion) and dosimetry for non-interacting spherical particles and their agglomerates in monolayer cell culture systems. Particle transport to cells is calculated by simultaneous solution of Stokes Law (sedimentation) and the Stokes-Einstein equation (diffusion). Results: The In vitro Sedimentation, Diffusion and Dosimetry model (ISDD) was tested against measured transport rates or cellular doses for multiple sizes of polystyrene spheres (20-1100 nm), 35 nm amorphous silica, ...
2010-11-30
Energy Technology Data Exchange (ETDEWEB)
The application of the large-bore direct injection high efficiency nebulizer (LB-DIHEN) for the determination of arsenic (As), cadmium (Cd), lead (Pb), and mercury (Hg) in urine by inductively coupled plasma mass spectrometry (ICP-MS) is described. The LB-DIHEN is compared with the standard method using a concentric pneumatic nebulizer and cyclonic spray chamber. In addition to the toxicological significance of As, Cd, Pb, and Hg, these elements represent a cross-section of analytical issues including spectral interferences (e.g., {sup 40}Ar{sup 35}Cl{sup +} on {sup 75}As{sup +} and {sup 98}Mo{sup 16}O{sup +} on {sup 114}Cd{sup +}) and memory effects (Hg). In this study, the low sample consumption of the LB-DIHEN is used to reduce the volume of urine needed for analysis, and to reduce the volume of final diluted sample required for analysis. Eliminating the spray chamber and reducing the dead volume of the nebulizer reduces memory effects, especially for analytes ...
2008-03-15
Multi-Phase Fracture-Matrix Interactions Under Stress Changes
Energy Technology Data Exchange (ETDEWEB)
The main objectives of this project are to quantify the changes in fracture porosity and multi-phase transport properties as a function of confining stress. These changes will be integrated into conceptual and numerical models that will improve our ability to predict and optimize fluid transport in fractured system. This report details our progress on: (a) developing the direct experimental measurements of fracture aperture and topology and fluid occupancy using high-resolution x-ray micro-tomography, (b) counter-current fluid transport between the matrix and the fracture, (c) studying the effect of confining stress on the distribution of fracture aperture and two-phase flow, and (d) characterization of shear fractures and their impact on multi-phase flow. The three-dimensional surface that describes the large-scale structure of the fracture in the porous medium can be determined using x-ray micro-tomography with significant accuracy. Several ...
2005-12-07
Fine ceramics center; Fuain seramikkusu senta
Energy Technology Data Exchange (ETDEWEB)
Fine ceramics center (JFCC) succeeded in the higher precision of thermal diffusivity measurement by the laser flash. This results are part of 'the research on thermophysical property measurement technique and standard substance of the functional material' by the intelligent establishing of a base promotion system of Science and Technology Agency. Cooperative research. thermal diffusivity with Natl. Res. Lab. of Metrology is one of the representative thermophysical property. The speed in which a heat transmits of the material is shown, and it is indispensable to the design of the high-temperature member subject. JFCC heralds the world as a standard substance for the thermal diffusivity measurement; 'TD-AL' using the alumina material is developed and is supplied in the spring in last year. Laser flash which uses laser beam for the heat source is general for the measurement. However, there was grinding undercut of slippage and heat ...
1999-11-01
Energy Technology Data Exchange (ETDEWEB)
The project aim is to model the hybrid plant at Vaesthamnsverket in Helsingborg using artificial neural networks (ANN) and integrating the ANN models, for online condition monitoring and thermoeconomic optimization, at Vaesthamnsverket. The definition of a hybrid plant is that it uses more than one fuel, in this case a natural gas fuelled gas turbine with heat recovery steam generator (HRSG) and a biomass fuelled steam boiler with steam turbine. The project is a continuation of previous projects where ANN training was done with operational data from the plant. The ANN models have, if required, been updated to better suit the purpose of this project. The thermoeconomic optimization takes into account current electricity prices, taxes, fuel prices etc. and calculates the current production cost along with the 'predicted' production cost. The tool also has a built in feature of predicting when a compressor wash is economically beneficial. The user interface is developed ...
2007-12-15
Clinical implementation of a convolution based algorithm for 3D treatment planning
International Nuclear Information System (INIS)
Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A computer controlled data acquisition system and a water tank where used ...
An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste
Energy Technology Data Exchange (ETDEWEB)
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm{sup -3} or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the ...
2007-08-21
An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste
International Nuclear Information System (INIS)
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm"-"3 or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the end ...
2007-08-21
A deterministic partial differential equation model for dose calculation in electron radiotherapy
International Nuclear Information System (INIS)
High-energy ionizing radiation is a prominent modality for the treatment of many cancers. The approaches to electron dose calculation can be categorized into semi-empirical models (e.g. Fermi-Eyges, convolution-superposition) and probabilistic methods (e.g. Monte Carlo). A third approach to dose calculation has only recently attracted attention in the medical physics community. This approach is based on the deterministic kinetic equations of radiative transfer. We derive a macroscopic partial differential equation model for electron transport in tissue. This model involves an angular closure in the phase space. It is exact for the free streaming and the isotropic regime. We solve it numerically by a newly developed HLLC scheme based on Berthon et al (2007 J. Sci. Comput. 31 347-89) that exactly preserves the key properties of the analytical solution on the discrete level. We discuss several test cases taken from the medical physics literature. A test case with an ...
2010-07-07
Physics and quality assurance of low dose rate brachytherapy
International Nuclear Information System (INIS)
Purpose: The purpose of this course is to review the physical principles underlying design, clinical application and execution of interstitial and intracavitary implants in the classical low dose-rate (LDR) range. This year, the course will focus on quality assurance of sources, applicators and treatment planning software. In addition, development of procedures and QA checks designed optimize treatment delivery accuracy and patient safety during each individual procedure will be reviewed. The level of presentation will be designed to accommodate both physicists and physicians. Implementation of recently published AAPM Task Group reports (no. 40, 'Comprehensive Quality Assurance' and No. 43, 'Dosimetry of Interstitial Brachytherapy Sources') will be reviewed. Outline: (A) General Principles (1) QA endpoints: temporal accuracy, positional accuracy, dose delivery accuracy, and safety of the patient, ...
Energy Technology Data Exchange (ETDEWEB)
The adverse effects and diagnostic accuracy of thallium-201 myocardial SPECT after intravenous infusion of adenosine triphosphate (ATP) were studied and compared with SPECT examinations with other type of loading. The subjects of the study were 147 patients with or without coronary artery disease, who underwent some type of loading SPECT and coronary arteriography (CAG) within 30 days. Myocardial ischemia was evaluated qualitatively in SPECT and was compared with CAG for the diagnostic accuracy of coronary artery disease. The degree of myocardial uptake defect was also calculated semiquantitatively using visual scoring method and compared with coronary artery severity score. The adverse effects occurred in 46.7% of ATP loading SPECT which was more frequent that DIP loading SPECT, but all of them were transient and mild. As for the diagnostic ability the ATP loading SPECT was as effective as other type of loading in qualitative interpretation, ...
1999-09-01
International Nuclear Information System (INIS)
The diagnostic accuracy is compared of the dual-isotope protocol and the conventional "2"0"1Tl protocol, for detection of the coronary artery disease (CAD) using data on a total of 69 patients after myocardial infarction (MI). The "2"0"1Tl protocol was used to examine 44 patients, the dual-isotope protocol was used with 25 patients. All patients were examined by coronarography; a narrowing of the artery by more than 50 % was considered significant for CAD. The sensitivity, specificity and diagnostic accuracy was 97.7 %, 100 % and 97.7 % resp. for the "2"0"1Tl protocol, and 95.2 %, 75 % and 92 % resp. for the dual-isotope protocol. A higher diagnostic accuracy of the dual-isotope protocol has not been proven, and the "2"0"1Tl protocol continues to be used for examinations of patients after MI
1998-08-01
International Nuclear Information System (INIS)
The primary aim was to evaluate delayed contrast-enhanced MRI in depicting perineural spread of hilar cholangiocarcinoma (CCC) and consequently to determine the capability of MRI/MRCP for staging CCC. Fifteen patients that underwent MRI/MRCP and surgical treatment were retrospectively included. Two radiologists evaluated MR images to assess delayed periductal enhancement, extent of bile duct stenosis, liver parenchymal and vascular involvement and presence of liver atrophy. An agreement between delayed enhancement of the bile duct walls and perineural neoplastic spread showed a very good correlation factor (0.93). The overall accuracy in detecting biliary neoplastic invasion was higher for delayed T1-weighted images (93.3%) than for the MRCP images (80%), and T1-delayed image increased the MR accuracy in assessing the neoplastic resectability (p < 0.05). MRI correctly predicted vascular involvement in 73% and liver involvement in 80% of the ...
2008-10-01
CT versus MRI in the study of the articular diseases of the knee
International Nuclear Information System (INIS)
The authors present a comparison between the diagnostic accuracy of Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) in the articular pathologies of the knee. CT and MRI were performed in 30 patients who subsequently underwent surgery. CT and MRI results were compared on three bases: technique, definition of normal anatomy, and diagnostic accuracy. CT allowed a standardization of the technique, while MRI was superior in defining normal anatomy - especially in the study of capsulo-ligamentous structures. In all cases the use of both CT and MRI allowed a correct diagnosis, showing the site, extent and gravity of the lesion. CT proved to be superior to MRI in 4 cases, while MRI corrected CT diagnosis in 11 cases; in 15 patients both techniques had the same diagnostic accuracy. Meniscal tears were better identified by CT, while MRI was superior in the detection of ligamentous lesions and in the characterization of ...
1988-01-01
Energy Technology Data Exchange (ETDEWEB)
Accuracy of an LLP system and a lightning frequency map is evaluated by using transmission line faults in Hokuriku area from November in 1993 to October in 1996. The accuracy and efficiency of the system were calculated by statistical methods. From the above results, the lightning frequency map with 10 minutes meshes was proved capable of replacing the Isokeraunic Level Map with 15 minutes meshes used now for lightning protection design. However, the correlation between the number of detected lightning flashes and transmission line faults in each mesh was found to be week. This result suggests that more detailed analysis taking account of the length of transmission lines in each mesh is necessary. The correlation is stronger in winter than in summer, despite the fact that there is difference in the lightning current distribution in each mesh in winter. This characteristic can be explained if upward flashes from transmission lines are dominant ...
1997-10-20
Summary of reference materials for the determination of the nutrient composition of foods
British Library Electronic Table of Contents (United Kingdom)
Certified reference materials (CRMs) play a critical role in validating the accuracy of nutrient data for food samples. A number of available food CRMs of differing matrix composition have assigned concentrations for various nutrients, along with associated uncertainty intervals (UIs) for those values. These CRMs have been used extensively in the United States Department of Agriculture?s (USDA) ongoing National Food and Nutrient Analysis Program (NFNAP) to monitor the accuracy of assays of key foods and nutrients consumed in the United States. A total of 690 assigned values for individual nutrients, including proximates, vitamins, macroelements, microelements, fatty acids, amino acids, and selected phytochemicals (e.g., carotenoids), were compiled from the certificates of analysis for 63 C...
2007-01-01
We assess the accuracy and relevance of the numerical algorithms based on the principles of Geometrical Optics (GO) and Physical Optics (PO) in the analysis of reduced-size homogeneous dielectric lenses prone to behave as open resonators. As a benchmark solution, we use the Muller boundary integral equations discretized with trigonometric Galerkin scheme that has guaranteed and fast convergence as well as controllable accuracy. The lens cross-section is chosen typical for practical applications, namely an extended hemiellipse whose eccentricity satisfies the GO focusing condition. The analysis concerns homogeneous lenses made of rexolite, fused quartz, and silicon with the size varying between 3 and 20 wavelengths in free space. We consider the 2-D case with both E- and H-polarized plane waves under normal and oblique incidence, and compare characteristics of the near fields.
2010-01-01
Sialography, echography and computed tomography in parotid gland study
International Nuclear Information System (INIS)
The diagnostic accuracy of sialography and ultrasonography (US) in the evaluation of parotid masses is evaluated. Furthermore the role of computed tomography (CT) in this pathology is discussed. In the personal experience US proved to be the best method in the recognition of a parotid tumor while sialography was superior in defining the intra or extraparotid site. The two investigations showed the same accuracy in the definition of benign or malignant nature of the mass. Therefore we consider US the only investigation in most istances; sialography could be performed when the site of the lesion is uncertain or an inflammatory lesion is suspected. CT is never the first investigation; its use is limited to a low number of cases, mainly for the evaluation of large masses and when the association US-sialography does not allow a sure diagnosis.
1985-01-01
International Nuclear Information System (INIS)
Comparative analysis of diagnostic accuracy (dignity determination) in CT-guided fine-needle biopsy (141 patients), CT (141), ultrasonography (89), angiography (50), and cholegraphy (ERCP, 55), was carried out in suspected space-occupying lesions of the pancreas. With accuracy of 86%, sensitivity of 37% and specificity of 92% fine-needle biopsy was superior to imaging procedures. Additional comparison of the results concerning the patients and Roc curves confirm the statements. For reduction of the number of imaging investigations a diagnostic algorithm is proposed, that starts with diagnostic CT and subsequent fine-needle biopsy controlled by CT. This would result in a more adequate use of angiography and ERCP and in the elimination of ultrasonography. (author).
Recent developments at ISOLTRAP towards a relative mass accuracy of exotic nuclei below $10^{-8}$
During the last two years, the performance of the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN (Geneva) has been considerably enhanced. Many technical improvements have been completed (i) to access nuclides that are produced in minute quantities of only 100 ions s/sup -1/, (ii) to increase the relative mass accuracy to 2003-01-01
Energy Technology Data Exchange (ETDEWEB)
Itaipu Binacional has taken a decision of executing a technological updating for the energy measurement system through the substitution of the current system by other one equipped with digital devices. The main reasons for that were the following: a) The equipment in operation were of an outdated generation b) The accuracy class of the existing equipment was of 0.5%, but the tendency for invoicing measurements was to install meters with accuracy class of 0.2% in the enterprises c) The requirements of ONS/MAE, in Brazil, which establishes the minimum requisites to be attended by invoicing measurement systems.
2001-07-01
Pedometer Accuracy in Elementary School Children while Walking, Skipping, Galloping, and Sliding
British Library Electronic Table of Contents (United Kingdom)
The purpose of this study was to examine the accuracy of the SW-701 (Yamax Corporation, Tokyo, Japan) and NL-800 (New-Lifestyles, Inc., Lee's Summit, Missouri, USA) pedometer in fifth-grade students while walking, skipping, galloping, sliding, and hopping. Counts registered by both pedometer models were significantly lower than actual counts while skipping, galloping, and sliding, and counts from the NL-800 were significantly lower than the SW-701 during these same movements. No significant differences in step counts were detected between actual counts and the SW-701 and between the pedometer models while walking and hopping; however, the NL-800 registered counts significantly higher than actual counts while hopping. Bland-Altman plots suggest the greatest variability occurred while skippi...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
In this work, we have investigated the capability of different bimetallic nanoparticle alloy combinations to be used in fibre optic temperature sensing based on the technique of surface plasmon resonance (SPR). The metals considered for the present analysis are silver, gold and aluminium. The analysis is derived mainly from the thermo-optic effect along with some fundamental concepts of metal optics such as surface scattering, phonon-electron scattering and electron-electron scattering. The performance of the sensor with three different bimetallic nanoparticle alloy combinations is evaluated and compared, numerically, in terms of its sensitivity and accuracy. On the basis of the comparison and some logistic criterion, we predict the best possible bimetallic alloy combination along with a requisite alloy composition ratio that simultaneously provides higher values of both sensitivity and accuracy which is not possible with any single metallic ...
2009-02-21
Monte Carlo treatment planning for photon and electron beams
British Library Electronic Table of Contents (United Kingdom)
During the last few decades, accuracy in photon and electron radiotherapy has increased substantially. This is partly due to enhanced linear accelerator technology, providing more flexibility in field definition (e.g. the usage of computer-controlled dynamic multileaf collimators), which led to intensity modulated radiotherapy (IMRT). Important improvements have also been made in the treatment planning process, more specifically in the dose calculations. Originally, dose calculations relied heavily on analytic, semi-analytic and empirical algorithms. The more accurate convolution/superposition codes use pre-calculated Monte Carlo dose "kernels" partly accounting for tissue density heterogeneities. It is generally recognized that the Monte Carlo method is able to increase accuracy even furt...
2007-01-01
Energy accounting for shared virtualized environments under DVFS using PMC-based power models
British Library Electronic Table of Contents (United Kingdom)
Virtualized infrastructure providers demand new methods to increase the accuracy of the accounting models used to charge their customers. Future data centers will be composed of many-core systems that will host a large number of virtual machines (VMs) each. While resource utilization accounting can be achieved with existing system tools, energy accounting is a complex task when per-VM granularity is the goal. In this paper, we propose a methodology that brings new opportunities to energy accounting by adding an unprecedented degree of accuracy on the per-VM measurements. We present a system - which leverages CPU and memory power models based in performance monitoring counters (PMCs) - to perform energy accounting in virtualized systems. The contribution of this paper is threefold. First, w...
2012-01-01
Development of a Weekly Load Forecasting Expert System
Energy Technology Data Exchange (ETDEWEB)
This paper describes the weekly load forecasting expert system (named WLoFy) which was developed and implemented for korea electric power corporation(KEPCO). WLoFy was designed to provide user oriented features with a graphical user interface to improve the user interaction. The various forecasting models such as exponential smoothing, multiple regression, artificial neural networks, rule-based model, and relative coefficient model also have been included in WLofy to increase the forecasting accuracy. The simulation based on historical data shows that the weekly forecasting results from WLoFy is an improvement when compared to the results from the conventional methods. Especially the forecasting accuracy on special days has been improved remarkably. (author). 9 refs., 5 figs., 6 tabs.
1999-04-01
Determine equilibrium absorption rates
Energy Technology Data Exchange (ETDEWEB)
Process engineers can predict quickly and accurately the equilibrium behavior of simultaneous H/sub 2/S and CO/sub 2/ absorptions in monoethanolamine and diethanolamine systems by using the nomographs developed by H.K. Ferguson Co. Correlation lines for temperature and amine concentration provided with the loading curves make the nomographs useful for any combination of temperature, concentration, and liquid loadings. The accuracy of the nomographs is within the acceptable range for normal engineering applications when the operating parameters lie in the region of practical gas-treating conditions. Correction curves given for each nomograph to improve the accuracy are generally not needed except for cases where the gas loadings are higher than 0.5 mole/mole of amine.
1980-04-01
Autonomous multi-sensor micro-system for measurement of ocean water salinity
British Library Electronic Table of Contents (United Kingdom)
This paper describes the design, fabrication and application of a micro-fabricated salinity sensor system. The theoretical electrochemical behaviour is described using electrical equivalent diagrams and simple scaling properties are investigated analytically and numerically using finite element method (FEM). The chip design and fabrication is described and measurement results of two different electrode designs are presented. The 4mm Formula Not Shown 4mm multi-sensor allows for salinity determination with an accuracy of Formula Not Shown 0.5psu through determination of the electrical conductivity, temperature and pressure with accuracies of Formula Not Shown 0.6mS, Formula Not Shown 0.065 Formula Not Shown C and Formula Not Shown 0.05bar, respectively.
2008-01-01
British Library Electronic Table of Contents (United Kingdom)
Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experi...
2007-01-01
British Library Electronic Table of Contents (United Kingdom)
The rolls and stand deflections induced by rolling force lead to a significant decrease in the radius prediction accuracy of the ring product in the in-plane roll-bending of strip. To precisely predict the deflections and control the radius, a new analytical model is developed. Numerical implementation is presented to solve the theoretical rolling force, the deflections as well as the inherent force-deflection relationship considering the interactions of the strip workpiece, the rolls and the stand. A series of profile measurements of the formed ring parts are made to assess the accuracy of the predicted deflections. Different control approaches are used in the experiments to validate the radius control model. The experimental results show that the model is reliable to control the radii wi...
2011-01-01
A new method for adiabatic flame temperature estimations of hydrocarbon fuels
Energy Technology Data Exchange (ETDEWEB)
This paper presents the application of artificial neural networks to adiabatic flame temperature prediction of hydrocarbon fuels. The investigation was conducted over a wide range of operating conditions in terms of fuel composition, pressure and temperature of reactants, fuel-air equivalence ratio and fuel vapour fraction. Several neural network models for predicting the flame temperature for different applicable fuel ranges were built and examined. The proper preparation of network training data and the appropriate choice of network parameters for achieving better prediction accuracy are discussed. The neural network prediction results were compared with those calculated by a thermodynamic and chemical equilibrium-based computer code - the NASA program CET89. It was shown that trained neural network models can provide the adiabatic flame temperature prediction with a good level of accuracy over a wide range of operating conditions. 16 refs., ...
1999-03-01
Energy Technology Data Exchange (ETDEWEB)
NO{sub x} compounds, specifically NO and NO{sub 2}, are pollutants and potent greenhouse gases. Compact and inexpensive NO{sub x} sensors are necessary in the next generation of diesel (CIDI) automobiles to meet government emission requirements and enable the more rapid introduction of more efficient, higher fuel economy CIDI vehicles. Because the need for a NO{sub x} sensor is recent and the performance requirements are extremely challenging, most are still in the development phase. Currently, there is only one type of NO{sub x} sensor that is sold commercially, and it seems unlikely to meet more stringent future emission requirements. Automotive exhaust sensor development has focused on solid-state electrochemical technology, which has proven to be robust for in-situ operation in harsh, high-temperature environments (e.g., the oxygen stoichiometric sensor). Solid-state sensors typically rely on yttria-stabilized zirconia (YSZ) as the oxygen-ion conducting ...
2010-11-01
XRF and PIXE method as trols for the element analysis of metallic glasses
International Nuclear Information System (INIS)
The radionuclide X-ray fluorescence and particle induced X-ray emission methods were used for rapid and nondestructive analysis of metallic glasses. The methods were compared for accuracy and precision with the atomic absorption method. Some results of the analyses of Fe_xNi_8_0_-_xB_2_0 materials are briefly reviewed. The distribution of elements along the width as well as the length and a qualitative analysis of the composition of material surfaces are considered. (author).
1986-01-01
XRF and PIXE analysis of metallic glasses
International Nuclear Information System (INIS)
Radionuclide X-ray fluorescence and particle induced X-ray emission methods were used for a rapid and nondestructive analysis of metallic glasses. The methods are compared in accuracy and precision with the atomic absorption method. Some results of analyses of Fe_xNi_8_0_-_xB_2_0 materials are briefly reviewed. The distribution of elements along the width and length, and a qualitative analysis of the composition of material surfaces are considered. (author) 3 refs.
1987-05-01
Towards an objective evaluation of tolerances for beam modeling in a treatment planning system
International Nuclear Information System (INIS)
The performance of a convolution/superposition based treatment planning system depends on the ability of the dose calculation algorithm to accurately account for physical interactions taking place in the tissue, key components of the linac head and on the accuracy of the photon beam model. Generally the user has little or no control over the performance of the dose calculation algorithm but is responsible for the accuracy of the beam model within the constraints imposed by the system. This study explores the dosimetric impact of limitations in photon beam modeling accuracy on complex 3D clinical treatment plans. A total of 70 photon beam models was created in the Pinnacle(TM) treatment planning system. Two of the models served as references for 6 MV and 15 MV beams, while the rest were created by perturbing the reference models in order to produce specific deviations in specific regions of the calculated dose profiles ...
2007-09-21
International Nuclear Information System (INIS)
This report presents criteria for the identification and evaluation of fire hazards in nuclear power stations. The report presents criteria that are consistent with the existing regulatory approach in Canada, and outlines engineering tools and analytical techniques currently available to deterministically analyse fire. The criteria presented cover the topics which should be included in a fire hazard analysis and provide details of each topic so that the accuracy of an analysis may be evaluated.
2000-12-10
Strain-gage for mining instruments
Energy Technology Data Exchange (ETDEWEB)
The proposed device incorporates an axle which has a roller bearing support mounted upon it. This support uses a cylindrical sleeve that comes in contact with the housing, the sensors, and the bearing support component. Metering accuracy is improved by placing roller bearing supports into grooves running through the protruding center sections of the sensor elements. These roller bearing supports interface with the cylindrical sleeve.
1982-01-01
... This is an amount less that the measurement accuracy of even the best meteorological instruments . So, is it really worth committing to 40 years of drastic carbon emissions reductions (which necessarily involves increasing the cost of hydrocarbon fuels in order to reduce fuel consumption, and force an industry-wide conversion to much more expensive alternative energy sources), all so that after nearly all of us are ...
Energy Technology Data Exchange (ETDEWEB)
A detailed definitive cost estimate is given for an ethanol/gasohol storage and blending terminal serving a planned distillery at a Louisiana sugar factory. Included are an analysis of the accuracy of the estimate, labor rates efficiency, materials and labor escalation, as well as detailed calculations for each account of the project. (LEW)
1982-04-01
Range and energy loss rate of 118 MeV "2"8Si in some polymers
International Nuclear Information System (INIS)
In the present work, range and energy loss rate of "2"8Si in four dielectric track detectors viz: Makrofol-KG (MFKG), Makrofol-G (MFG), Triafol-BN (TBN) and LR-115 (cellulose nitrate) have been measured. To calculate these parameters, a curve fitting method was proved to be very useful and easier with more accuracy. (author)
1999-01-01
Energy Technology Data Exchange (ETDEWEB)
Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and displayed four images as a subsidiary diagnosis. The upper two ...
1989-08-01
Pulmonary nodule detection of chest phantom with CRT images
International Nuclear Information System (INIS)
Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and displayed four images as a subsidiary diagnosis. The upper two ...
1989-01-01
Position detector design using an electrostatic application of ANSYS[sup TM
Energy Technology Data Exchange (ETDEWEB)
The design of beam position monitor (BPM) stripline detectors has been enhanced by using the finite element code ANSYS[sup TM]. Available from Swanson Engineering, ANSYS[sup TM] was developed to solve Poisson's equation in stress and thermal analysis applications. The code is readily adaptable to solving electrostatic problems. The designs of several beam detectors were iterated by calculating electrode capacitances and characteristic impedances to better than 1% accuracy.
1994-10-10
International Nuclear Information System (INIS)
Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).
1980-01-01
Multi-mode wavepath depth imaging for the SEG/EAGE salt model
Energy Technology Data Exchange (ETDEWEB)
Elastic depth imaging of both P-wave and S-wave prestack seismic reflection data is formulated as a degraded form of Kirchhoff migration known as Wavepath Migration (WM). Applications to the SEG/EAGE salt model show that the method is sufficiently versatile anti relaitively inexpensive. It handles S-wave data with at least the same accuracy as Pwave data when local mode conversions are removed. WM also provides an understanding of multi-mode illumination.
2003-01-01
Moxel: A molar tooth voxel model for dosimetric studies
Energy Technology Data Exchange (ETDEWEB)
Stylized numerical models of the tooth are usually employed in qualification procedure related to Electronic Paramagnetic Resonance in long-term accidental contamination dose reconstruction. In this work a voxel model was developed from the microCT image data set of a human non contaminated molar tooth. A stylized model, reproducing the characteristics of the voxel model, was also created in order to investigate the level of accuracy that can be obtained in this kind of study.
2010-02-15
Microfluidic systems and methods for transport and lysis of cells and analysis of cell lysate
Energy Technology Data Exchange (ETDEWEB)
Microfluidic systems and methods are disclosed which are adapted to transport and lyse cellular components of a test sample for analysis. The disclosed microfluidic systems and methods, which employ an electric field to rupture the cell membrane, cause unusually rapid lysis, thereby minimizing continued cellular activity and resulting in greater accuracy of analysis of cell processes.
2008-09-02
Magnetic diagnostic of beta poloidal and internal inductance of plasma in the TCA/BR tokamak
Energy Technology Data Exchange (ETDEWEB)
This report continues the studies of simplified methods, of magnetic diagnostics in application to TCA/BR tokamak. Here we study the accuracy of known formula for {beta}{sub 1} + l{sub 1}/2 determination from the poloidal magnetic field asymmetry. Errors of the diamagnetic measurements due to vibrations of the vacuum vessel are also considered. (author). 3 refs., 1 fig., 1 tab.
1996-12-31
Laser induced fluorescence measurements of the mixing of fuel oil with air
Energy Technology Data Exchange (ETDEWEB)
We report on measurements of the mixing of fuel oil with air at atmospheric pressure in an industrial premixed gas turbine burner. The concentration of the vaporized fuel oil was measured with laser induced fluorescence. We reason that the fuel oil concentration can be considered with good accuracy as proportional to the fluorescence intensity. (author) 6 fig., 3 refs.
1999-08-01
International Nuclear Information System (INIS)
Both the accuracy and real-time are quite strictly required for the RCS thermal-hydraulic model of the simulation of nuclear power station. So, a large amount of reasonable simplifications should be carried on. The author introduces the RCS thermal-hydraulic model of the full scope simulator of Daya Bay Nuclear Power Station, and emphasizes on the fundamental hypotheses and computation method of its kernel part--DEFI programme.
Heterogeneous mechanism of nucleation in a superheated cryogenic fluid flow
Energy Technology Data Exchange (ETDEWEB)
A model of heterogeneous mechanism of nucleation on impurity particles in a fluid volume is proposed. The particle spectrum is reproduced by solving the ''inverse'' problems on stationary outflow of a boiling parahydrogen with the use of experimental data of authors. A relation for a closure of the equation system describing a non-equilibrium outflow is obtained. It is shown that within the investigated parameter range one manages to calculate the characteristics of a stationary outflow with a satisfactory accuracy.
1984-03-01
Estimating demolition cost of plutonium buildings for dummies
Energy Technology Data Exchange (ETDEWEB)
The primary purpose of the Rocky Flats Field Office of the US Department of Energy is to decommission the entire plant. In an effort to improve the basis and the accuracy of the future decommissioning cost, Rocky Flats has developed a powerful but easy-to-use tool to determine budget cost estimates to characterize, decontaminate, and demolish all its buildings. The parametric cost-estimating tool is called the Facilities Disposition Cost Model (FDCM).
2000-07-01
Dynamic behavior of a solar-heated receiver of a gas turbine plant
Energy Technology Data Exchange (ETDEWEB)
The mainly nonstationary operation of a solar-heated receiver can be simulated with sufficient accuracy only if data about the dynamic behavior are available. For this reason, the dynamic behavior of a solar cavity receiver with parabolic dish collector is investigated. The development of a mathematical simulation considering heat transfer and storage processes is presented and the procedure for a numerical solution is illustrated. The performance of the calculation method is finally demonstrated by simulating the passage of a cloud.
1987-01-01
Dynamic behavior of a solar heated receiver of a gas turbine plant
Energy Technology Data Exchange (ETDEWEB)
The mainly instationary operation of a solar heated receiver can be simulated with sufficient accuracy only if data about the dynamic behavior are available. For this reason, the dynamic behavior of a solar cavity receiver with parabolic dish collector is investigated. The development of a mathematical simulation considering heat transfer and storage processes is presented and the procedure for a numerical solution is illustrated. The performance of the calculation method is finally demonstrated by simulating the passage of a cloud.
1986-01-01
Direct measurements of secondary water inventory of steam generator PGV-213 in operation
Energy Technology Data Exchange (ETDEWEB)
Results of weight measurement of PGV-213 steam generator during filling in, heating-up and power increase are described. Special measurement system based on stress gauges has been developed. Method of derivation of secondary water inventory is described. Comparison of the data for two steam generators prove accuracy of the measurements. (orig.). 1 refs.
1997-12-31
International Nuclear Information System (INIS)
A procedure for the determination of lead in various biological and environmental samples by "2"0"3Pb radioisotope dilution substoichiometric method is presented. The accuracy of the method by comparison with the literature values of reference materials appears to be good. The standard deviation of the method is less than 10%, and detection limit is about 0.1 #mu#g of lead. (author) 5 refs.
Computed tomography of the urinary bladder. Clinical application of the olive oil-filled method
Energy Technology Data Exchange (ETDEWEB)
Out of one hundred cases of the urinary bladder abnormalities examined by this method, CT staging and pathological correlations were investigated in 61 cases of the urinary bladder neoplasms. Accuracy of CT staging was 87% in this series with possible exception of 6 cases involving the bladder base and dome. CT scan using this method is the most reliable procedure to determine the treatment modalities of the urinary bladder tumors.
1982-01-01
Comparison of ion chromatography and titrimetry for determination of sulfur in fuel oils
Energy Technology Data Exchange (ETDEWEB)
A comparison was made of Parr bomb ion chromatographic and titrimetric methods to determine sulfur in fuel oils. The two methods are comparable in precision and accuracy. When rapid sulfur determination in a number of samples is desired, the titrimetry method appears to be an appropriate choice between the two methods. l3 tables.
1982-12-01
Assessing predictive skill of models to optimise crop management and design
Environmental Research Database
DescriptionAn ability to foresee impacts on output is invaluable to any industry; good prediction is the basis of good management. Many research models can predict crop performance, but the skill (used here to include accuracy, precision, facility and credibility) of these predictions is rarely assessed, so is not well known. The only research model successfully adopted for practical purposes in the UK is the Broom's Barn Beet Model. Thus we propose here, research to assess and publish the skill of the [continued...
2004-01-30
Absolute absorption of ozone in the midinfrared
Energy Technology Data Exchange (ETDEWEB)
The absolute absorption of ozone in the midinfrared has been measured relative to 253.7-nm ultraviolet absorption to an accuracy of 1% using a Bruker Fourier transform spectrometer. These new results agree with previous measurements by diode laser measurements after the latter are corrected for more recent infrared calculations and ultraviolet cross sections. They also agree with a determination based on refractive index measurements in the infrared. 16 refs., 4 figs., 3 tabs.
1992-12-20
DNA isolation procedures significantly influence the outcome of PCR-based detection of human pathogens. Unlike clinical samples, DNA isolation from food samples such as fresh and fresh-cut produce has remained a formidable task and has hampered the sensitivity and accuracy of molecular methods. We...
A nonlinear positive method for solving the transport equation on course meshes
Energy Technology Data Exchange (ETDEWEB)
A new nonlinear S{sub n} transport differencing scheme for slab geometry is presented that is fourth order accurate for small meshes and is strictly positive. The new scheme has been coded into the existing ONELD code and tested. Numerical results to demonstrate the accuracy and positivity of this new scheme are presented.
1994-02-01
International Nuclear Information System (INIS)
Full text: A semiempirical algorithm for absorbed dose calculation at off-axis points in irregular beams was implemented. It is well known that semiempirical methods are very useful because of their easy implementation and its helpfulness in dose calculation in the clinic. These methods can be used as independent tools for dosimetric calculation in many applications of quality assurance. However, the applicability of such methods has some limitations, even in homogeneous media, specially at off axis points, near beam fringes or outside the beam. Only methods derived from tissue-air-ratio (TAR) or scatter-maximum-ratio (SMR) have been devised for those situations, many years ago. Despite there have been improvements for these manual methods, like the Sc-Sp ones, no attempt has been made to extend their usage at off axis points. In this work, a semiempirical formalism was introduced, based on the works of Venselaar et al. (1999) and Sanz et al. (2004), aimed to the Sc-Sp separation. This ...
2008-10-19
Energy Technology Data Exchange (ETDEWEB)
In this thesis, increased hemicellulose retention during kraft pulping has been studied. The work has been divided into three parts: i) Development of an accessible and reliable method for determination of carbohydrate composition of kraft pulps ii) Investigation of the composition and molecular mass distributions of the carbohydrates in kraft pulps with increased hemicellulose content iii) Investigation of the effect of increased hemicellulose content on the sheet properties of kraft pulps with increased hemicellulose content. A method for carbohydrate determination was developed. In this method, enzymes are used to hydrolyse the pulp into monosaccharides. A relatively mild acid hydrolysis is performed prior to detection on an HPLC with an RI-detector. The pulp is not derivatized and no pre-treatment (mechanical or chemical) is needed to determine the carbohydrate composition using the method developed here. Peak deconvolution software is used to improve the ...
2008-07-01
Energy Technology Data Exchange (ETDEWEB)
The following paper is focused on the numerical modelling of the transient radon diffusion through radon-proof membranes during the measurement of their radon diffusion coefficient. The major aim of such numerical modelling is to increase the accuracy of radon diffusion coefficients derived from the measured data sets. The developed complex ''transient'' numerical model is able to calculate the radon diffusion coefficient with sufficient accuracy from almost any data set - even from a short-time measurement with a non-linear course of results. This numerical model can also be used for various analyses of transient radon transfer processes (e.g. for the calculation of radon distribution curves within the membrane). The following paper presents governing equations for the simulation model, together with a brief description of algorithms incorporated in the newly developed software package, which can be used ...
2009-06-15
International Nuclear Information System (INIS)
In the convolution/superposition method of photon beam dose calculations, inhomogeneities are usually handled by using some form of scaling involving the relative electron densities of the inhomogeneities. In this paper the accuracy of density scaling as applied to primary electrons generated in photon interactions is examined. Monte Carlo calculations are compared with density scaling calculations for air and cork slab inhomogeneities. For individual primary photon kernels as well as for photon interactions restricted to a thin layer, the results can differ significantly, by up to 50%, between the two calculations. However, for realistic photon beams where interactions occur throughout the whole irradiated volume, the discrepancies are much less severe. The discrepancies for the kernel calculation are attributed to the scattering characteristics of the electrons and the consequent oversimplified modeling used in the density scaling method. A technique called the ...
The Eddy Experiment: accurate GNSS-R ocean altimetry from low altitude aircraft
During the Eddy Experiment, two synchronous GPS receivers were flown at 1 km altitude to collect L1 signals and their reflections from the sea surface for assessment of altimetric precision and accuracy. Wind speed (U10) was around 10 m/s, and SWH up to 2 m. A geophysical parametric waveform model was used for retracking and estimation of the lapse between the direct and reflected signals with a 1-second precision of 3 m. The lapse was used to estimate the SSH along the track using a differential model. The RMS error of the 20 km averaged GNSS-R absolute altimetric solution with respect to Jason-1 SSH and a GPS buoy measurement was of 10 cm, with a 2 cm mean difference. Multipath and retracking parameter sensitivity due to the low altitude are suspected to have degraded accuracy. This result provides an important milestone on the road to a GNSS-R mesoscale altimetry space mission.
2004-01-01
International Nuclear Information System (INIS)
Quantitative gated SPECT (QGS) was evaluated in 7 normal volunteers and 31 patients with cardiac diseases. Adequate cut off value of a prefilter was 0.45. In phantom, the left ventricular volume value was 93.9% of determined value by 180-degree projection in L type and 98.8% by 360-degree projection in opposed type. In normal volunteers, LVEF measured by QGS program related to value by first pass method. As for functional map, regional EF and wall motion decreased at the septum side, and wall thickening at base side of heart. Good correlation was recognized (p<0.0001) between blood flow image and functional map (regional EF and wall thickening). In 20 cases of acute myocardial infarction, lesion was detected conspicuously in regional EF and wall motion. The accuracy of coronary arterial stenosis improved in functional map (regional EF 92%, wall motion 92% and wall thickening 88%). In particular, the accuracy of 3 rami lesion was 100% in ...
1998-08-01
Short-term energy outlook, Annual supplement 1995
Energy Technology Data Exchange (ETDEWEB)
This supplement is published once a year as a complement to the Short- Term Energy Outlook, Quarterly Projections. The purpose of the Supplement is to review the accuracy of the forecasts published in the Outlook, make comparisons with other independent energy forecasts, and examine current energy topics that affect the forecasts. Chap. 2 analyzes the response of the US petroleum industry to the recent four Federal environmental rules on motor gasoline. Chap. 3 compares the EIA base or mid case energy projections for 1995 and 1996 (as published in the first quarter 1995 Outlook) with recent projections made by four other major forecasting groups. Chap. 4 evaluates the overall accuracy. Chap. 5 presents the methology used in the Short- Term Integrated Forecasting Model for oxygenate supply/demand balances. Chap. 6 reports theoretical and empirical results from a study of non-transportation energy demand by sector. The empirical analysis involves ...
1995-07-25
Risk management in design engineering bids
Energy Technology Data Exchange (ETDEWEB)
Accurate engineering cost estimates are critical in developing bids for new work, and for effective resource allocation and project control. This study reports on design estimating methods found in the literature, and on the results of two empirical studies of how estimating techniques are used in professional practice and their accuracy. The study found great reliance on a classic {open_quotes}activity analysis{close_quotes} approach to estimating design resources, and significant hazards in commonly used parametric techniques. The study found that project managers expect their estimates to be accurate (with 80% confidence interval) of between -10% to +25%. The study also found that actual bids between engineering firms had a much greater range (-40% to +45%) than can be explained by accuracy. Perhaps most importantly the study found that none of the sampled design firms used probabilistic techniques to optimize their project bids or to manage ...
1995-06-01
Prediction of Skin Sensitization with a Particle Swarm Optimized Support Vector Machine
Skin sensitization is the most commonly reported occupational illness, causing much suffering to a wide range of people. Identification and labeling of environmental allergens is urgently required to protect people from skin sensitization. The guinea pig maximization test (GPMT) and murine local lymph node assay (LLNA) are the two most important in vivo models for identification of skin sensitizers. In order to reduce the number of animal tests, quantitative structure-activity relationships (QSARs) are strongly encouraged in the assessment of skin sensitization of chemicals. This paper has investigated the skin sensitization potential of 162 compounds with LLNA results and 92 compounds with GPMT results using a support vector machine. A particle swarm optimization algorithm was implemented for feature selection from a large number of molecular descriptors calculated by Dragon. For the LLNA data set, the classification accuracies are 95.37% and 88.89% for the ...
2009-07-17
Position of nuclear-medical techniques for evaluation of loosened total hip endroprostheses
Energy Technology Data Exchange (ETDEWEB)
For diagnosis of loosening or infection after implantation of a single-side or double-side total hip endoprosthesis 59 patients being in pain were investigated by a combination of bone scan (Technetium-99m DPD) and leucocyte scan (Indium-111 labelled leucocytes). The correlation between clinical results and scintigraphic findings revealed: bone scintigraphy detects loosening of prostheses with 95% sensitivity (45/47); bone scintigraphy excludes an instable prosthesis with 89% specificity (3/27). 45% of the loosened prostheses revealed an infection (21/47): leucocyte scintigraphy could detect 17 correct positive. Three leucocyte scans of 53 prostheses without clinical signs of infection were false positive. Therefore, leucocyte scintigraphy had a sensitivity of 91% and a specificity of 94% for detecting infection. Bone scintigraphy can detect loosening of prostheses with 93% accuracy, Indium-111 labelled leucocyte scintigraphy can detect infection of the prosthesis ...
1985-10-01
Energy Technology Data Exchange (ETDEWEB)
The most recently developed control technologies in a hot strip mill are described. Preview AGC has been developed with a preview control synthesis. It controls roll gaps by using the previous information of disturbances. The disturbances which are concerned are derived from the rolling force, the roll gap and the thickness of a previous stand. The thickness accuracy and the availability of mill have been improved by this technology. An on-line roll grinding (ORG) system with an on-line roll profile meter (OPM) has been developed for the purpose of achieving schedule-free rolling. The ORG smooths the worn and roughed surface of a work roll and OPM can measure the profile of a revolving roll without contact. The data obtained by the OPM are given as feedback information to the ORG. As a result, grinding accuracy has been improved and rolling restriction on width has been relaxed widely. (author)
1999-12-01
Least-squares analyses were performed on a set of atomic masses using standard and generalized senaiempirical mass laws. Presumably because of errors in the assured form of the standand mass law, its least-squares coefficients can be determined at best to an accuracy of about 10%, and masses are predicted with an uncertainty of several Mev/c/sup 2/. The standard mass law was generalized by addition of shell effect and deformation terms. While the least-squares fitting of the generalized mass law is better than for the standard mass law, it is still not possible to predict atomic masses to an accuracy better than a few Mev/c/sup 2/. The nuclear deformations and the well depth . of the nuclear interaction obtained from the additional mass-law terms are in reasonable agreement with more accurate determinations by other methods. A similar statement applies to the nuclear radius constant as obtained from the ...
1959-11-15
International Nuclear Information System (INIS)
The linearized-augmented-plane-wave (LAPW) method for thin films is generalized by removing the remaining shape approximation to the potential inside the atomic spheres. A new technique for solving Poisson's equation for a general charge density and potential is described and implemented in the film LAPW method. In the resulting full-potential LAPW method (FLAPW), all contributions to the potential are completely taken into account in the Hamiltonian matrix elements. The accuracy of the method: already well known for clean metal surfaces: is demonstrated for the case of a nearly free (noninteracting) O_2 molecule which is a severe test case of the method because of its large anisotropic charge distribution. Detailed comparisons show that the accuracy of the FLAPW results for O_2 exceeds that of existing state-of-the-art local-density linear-combination-of-atomic-orbitals (LCAO)-type calculations, and that taking the full potential LAPW results ...
Dose planning and dose delivery in radiation therapy
International Nuclear Information System (INIS)
A method has been developed for calibration of CT-numbers to volumetric electron density distributions using tissue substitutes of known elemental composition and experimentally determined electron density. This information have been used in a dose calculation method based on photon and electron interaction processes. The method utilizes a convolution integral between the photon fluence matrix and dose distribution kernels. Inhomogeneous media are accounted for using the theorems of Fano and O'Connor for scaling dose distribution kernels in proportion to electron density. For clinical application of a calculated dose plan, a method for prediction of accelerator output have been developed. The methods gives the number of monitor units that has to be given to obtain a certain absorbed dose to a point inside an irregular, inhomogeneous object. The method for verification of dose distributions outlined in this study makes it possible to exclude the treatment related variance contributions, ...
2008-08-01
Energy Technology Data Exchange (ETDEWEB)
With using artificial neural networks (ANNs), an analytical study related to the heated length effect on critical heat flux (CHF) has been carried out to make an improvement of the CHF prediction accuracy based on local condition correlations or table. It has been carried out to suggest a feasible criterion of the threshold length-to-diameter (L/D) value in which heated length could affect CHF. And within the criterion, a L/D correction factor has been developed through conventional regression. In order to validate the developed L/D correction factor, CHF experiments for various heated lengths have been carried out under low and intermediate pressure conditions. The developed threshold L/D correlation provides a new feasible criterion of L/D threshold value. The developed correction factor gives a reasonable accuracy for the original database, showing the error of -2.18% for average and 27.75% for RMS, and promising results for new experimental ...
1998-12-31
Energy Technology Data Exchange (ETDEWEB)
Authors developed a C-arm type radiosurgery system of the linear accelerator suitable for stereotactic radiation therapy and a software for arranging 3-dimensional therapy in the system. In this system, the gantry far conical irradiation of 4 MV (0.6-3 Gy/min) and 6 MV (0.9-4.5 Gy/min) X ray or electron beam for the therapy was connected to a newly designed C-arm and was made capable of rotating around either of the axes crossing vertically. With this system, it became unnecessary to move the bed table of the patient for getting suitable distribution of radiation dose. The local accuracy which was measured by the CCD videocamera on the gantry, was within 0.5 mm from the radiation center. The system made it possible to shorten the irradiation time and to improve the local accuracy of irradiating site. The clinical trial was begun from June, 1996. (K.H.)
1996-10-01
Energy Technology Data Exchange (ETDEWEB)
Radiographic images generated by the real-time neutron radiography system (RTNR) are analyzed by customized image processing software of the determination of instantaneous void fraction distribution. The cross-sectional averaged axial void fraction profiles and the two-dimensional void fraction profiles are determined simultaneously for each image. Various flow regimes are generated to determine if the RTNR system can accurately predict the void distribution in the radial, axial, and temporal coordinates. The results show the RTNR system correctly determines the void fraction distribution for each flow regime; however, accuracy decreases with decreasing void fraction. For net water thicknesses > 1.0 cm, the accuracy decreases with increasing water thickness due to the extreme sensitivity of thermal neutron interactions with light water. Heavy water is a more suitable fluid than light water for void fraction measurements in large-diameter ...
1995-01-01
Energy Technology Data Exchange (ETDEWEB)
The industrial standard process for the purification of natural gas is to remove acid gases, mainly hydrogen sulfide and carbon dioxide, by the absorption and reaction of these gases with alkanolamines. The natural gas industry requires vapor-liquid equilibrium (VLE) data to develop more energy efficient amine mixtures. Some energy reductions have been realized in the past decade by applying such amine systems as hindered amines, methyldiethanolamine (MDEA), and MDEA based amine mixtures. However, the lack of reliable and accurate VLE data impedes the commercial application of these more efficient alkanolamine systems. The first objective of this project is to improve the accuracy of vapor-liquid equilibrium measurements at low hydrogen sulfide concentrations. The second objective is to make VLE measurements for amine mixtures. By improving the accuracy of the VLE data on MDEA and other amines, energy savings can be implemented in the many ...
1995-08-01
Energy Technology Data Exchange (ETDEWEB)
The industrial standard process for the purification of natural gas is to remove acid gases, mainly hydrogen sulfide and carbon dioxide, by the absorption and reaction of these gases with alkanolamines. Inadequate data for vapor -- liquid equilibrium (VLE) hinder the industry from converting operations to more energy efficient amine mixtures and conserving energy. Some energy reductions have been realized in the past decade by applying such amine systems as ``hindered`` amines, methyldiethanolamine (MDEA), and MDEA based amine mixtures. However, the lack of reliable and accurate fundamental VLE data impedes the commercial application of these more efficient alkanolamine systems. The first project objective is to improve the accuracy of vapor -- liquid equilibrium measurements at low hydrogen sulfide concentrations. The second project objective is to measure the VLE for amine mixtures. By improving the accuracy of the VLE measurements on MDEA ...
1991-09-01
Energy Technology Data Exchange (ETDEWEB)
The industrial standard process for the purification of natural gas is to remove acid gases, mainly hydrogen sulfide and carbon dioxide, by the absorption and reaction of these gases with alkanolamines. Inadequate data for vapor -- liquid equilibrium (VLE) hinder the industry from converting operations to more energy efficient amine mixtures and conserving energy. Some energy reductions have been realized in the past decade by applying such amine systems as hindered'' amines, methyldiethanolamine (MDEA), and MDEA based amine mixtures. However, the lack of reliable and accurate fundamental VLE data impedes the commercial application of these more efficient alkanolamine systems. The first project objective is to improve the accuracy of vapor -- liquid equilibrium measurements at low hydrogen sulfide concentrations. The second project objective is to measure the VLE for amine mixtures. By improving the accuracy of the VLE ...
1991-09-01
An imaging comparison of three depth migration algorithms on Foothills datasets
Energy Technology Data Exchange (ETDEWEB)
Three popular imaging methods were used to carry out seismic migration from the Alberta foothills: Kirchhoff integral, reverse-time and explicit finite-difference migration methods. The imaging comparisons of reverse-time, Kirchhoff and f-x post-stack depth migration leads to the following conclusions. All of the three migration methods can provide acceptable and well-imaged intermediate results on the simplest model. Post-stack migration was not very sensitive to the accuracy of the velocity field once a reliable structural stack was available. With respect to the imaging accuracy and calculation cost, the Kirchhoff migration method seemed to be superior to reverse-time and f-x migration algorithms because its results on different kinds of velocity cases were basically kept coherent and consistent with the velocity model given by Mobil. Because of the lack of an accurate velocity field, reverse-time migration was less stable than the other two ...
1999-11-01
An imaging comparison of three depth migration algorithms on Foothills datasets
Energy Technology Data Exchange (ETDEWEB)
Three popular imaging methods were used to carry out seismic migration from the Alberta foothills: Kirchhoff integral, reverse-time and explicit finite-difference migration methods. The imaging comparisons of reverse-time, Kirchhoff and f-x post-stack depth migration leads to the following conclusions. All of the three migration methods can provide acceptable and well-imaged intermediate results on the simplest model. Post-stack migration was not very sensitive to the accuracy of the velocity field once a reliable structural stack was available. With respect to the imaging accuracy and calculation cost, the Kirchhoff migration method seemed to be superior to reverse-time and f-x migration algorithms because its results on different kinds of velocity cases were basically kept coherent and consistent with the velocity model given by Mobil. Because of the lack of an accurate velocity field, reverse-time migration was less stable than the other two ...
1999-01-01
Alternative methods to determine headwater benefits
Energy Technology Data Exchange (ETDEWEB)
In 1992, the Federal Energy Regulatory Commission (FERC) began using a Flow Duration Analysis (FDA) methodology to assess headwater benefits in river basins where use of the Headwater Benefits Energy Gains (HWBEG) model may not result in significant improvements in modeling accuracy. The purpose of this study is to validate the accuracy and appropriateness of the FDA method for determining energy gains in less complex basins. This report presents the results of Oak Ridge National Laboratory`s (ORNL`s) validation of the FDA method. The validation is based on a comparison of energy gains using the FDA method with energy gains calculated using the MWBEG model. Comparisons of energy gains are made on a daily and monthly basis for a complex river basin (the Alabama River Basin) and a basin that is considered relatively simple hydrologically (the Stanislaus River Basin). In addition to validating the FDA method, ORNL was asked to suggest refinements ...
1997-11-10
Energy Technology Data Exchange (ETDEWEB)
Analytical methods considering 3-D resistivity distribution, in particular, finite element method (FEM) were studied to improve the reliability of electromagnetic exploration. Integral equation, difference calculus, FEM and hybrid method are generally used as computational 3-D modeling method. FEM is widely used in various fields because FEM can easily handle complicated shapes and boundaries. However, in electromagnetic method, the assumption of continuous electric field is pointed out as important problem. The normal (orthogonal) component of current density should be continuous at the boundary between media with different conductivities, while this means that the normal component of electric field is discontinuous. In FEM, this means that current channeling is not properly considered, resulting in poor accuracy. Unless this problem is solved, FEM modeling is not practical. As one of the solutions, it is promising to specifically incorporate interior boundary ...
1996-10-01
Accuracy improvement of T-history method for measuring heat of fusion of various materials
Energy Technology Data Exchange (ETDEWEB)
T-history method, developed for measuring heat-of-fusion of phase change material (PCM) in sealed tubes, has the advantages of a simple experimental device and convenience with no sampling process. However, some improper assumptions in the original method, such as using a degree of supercooling as the end of latent heat period and neglecting sensible heat during phase change, can cause significant errors in determining the heat of fusion. We have improved this problem in order to predict better results. The present study shows that the modified T-history method is successfully applied to a variety of PCMs such as paraffin and lauric acid having no or a low degree of supercooling. Also it turned out that selected periods for sensible and latent heat do not significantly affect the accuracy of heat- of-fusion. As a result, the method can provide an appropriate means to assess a newly developed PCM by a cycle test even if a very accurate value cannot be obtained. ...
2004-06-01
International Nuclear Information System (INIS)
Accurate dose calculation in radiation treatment planning is most important for successful treatment. Since human body is composed of various materials and not an ideal shape, it is not easy to calculate the accurate effective dose in the patients. Many methods have been proposed to solve inhomogeneity and surface contour problems. Monte Carlo simulations are regarded as the most accurate method, but it is not appropriate for routine planning because it takes so much time. Pencil beam kernel based convolution/superposition methods were also proposed to correct those effects. Nowadays, many commercial treatment planning systems have adopted this algorithm as a dose calculation engine. The purpose of this study is to verify the accuracy of the dose calculated from pencil beam kernel based treatment planning system comparing to Monte Carlo simulations and measurements especially in inhomogeneous region. Home-made inhomogeneous phantom, Helax-TMS ver. 6.0 and Monte ...
2002-10-20
A boundary integral approach to unstable solidification
Energy Technology Data Exchange (ETDEWEB)
We consider the supercooled Stefan problem with a general anisotropic curvature- and velocity-dependent boundary condition on the moving interface. We present numerical methods, based on an integral equation formulation and including a new algorithm for moving curves with curvature-dependent velocity. These methods compute a periodic interface with {ital O}({Delta}{ital t}) accuracy, where {Delta}{ital t} is the time step. Previous work has been limited to short time spans and achieved slightly less than {ital O}({Delta}{ital t}{sup 1/2}) accuracy. Accurate numerical results are seen to agree with the predictions of linear stability theory. This agreement has eluded previous authors, because their numerical methods suffered from grid effects and their linear stability theory was incorrect. We study the long-time evolution of an unstable interface. Our computations exhibit the beginnings of a sidebranching instability when the boundary condition ...
1989-12-01
Energy Technology Data Exchange (ETDEWEB)
Nuclear medicine and magnetic resonance imaging (MRI) are widely used in cardiac diagnostics. Both techniques have been carefully evaluated and are equivalent for the assessment of regional and global wall motion as well as the evaluation of ejection fraction and cardiac volumes, though MRI is herein currently seen as gold standard. For evaluation of myocardial perfusion, extensive data exist for nuclear imaging, that, next to high diagnostic accuracy for evaluation of coronary artery disease, show incremental prognostic information and allow for independent risk stratification. Because of rapid technical advance, myocardial perfusion imaging has also become feasible with cardiac MRI. Results of recent studies are promising, but the data are few compared to perfusion scintigraphy. For viability assessment in patients with ischemic cardiomyopathy, positron emission tomography (PET) with FDG is currently seen as gold standard. However, single ...
2003-12-01
What's happening out there? (Climatic change impacts)
International Nuclear Information System (INIS)
This article briefly comments on some stumbling-blocks to climatic change modelling accuracy - in assessments of the greenhouse effect, 25% (missing link) of atmospheric carbon dioxide absorption is still unaccounted for; 1989 World Bank estimates of the Amazon rain forest deforestation rate have since proven to be inaccurate; there are difficulties in assessing the movement of the earth's crust relative to variations in sea level; and different studies vary in results relative to global temperature measurement and trend assessment. The need for an assessment of the economic impacts of increased atmospheric concentrations of carbon dioxide is also pointed out.
1990-01-01
Visualization of two-phase flow eddies in rectangular channels using real-time neutron radiography
Energy Technology Data Exchange (ETDEWEB)
Bubbly and slug flows have been analyzed using the afore-mentioned techniques. An image series of bubbly-slug flow is shown. The image separation time is 17 ms, and the total flow length is {approx} 10 cm. A circular eddy pattern that follows the slug can be readily seen and tracked, although reliability is low due to motion in the transverse direction. This motion also adds considerable error to the velocity measurements using image recognition technique. This will increase the reliability and accuracy of the tracking method.
1994-12-31
Vibrations of circular cylindrical shells
An exact solution method for the free vibration problem of thin circular cylindrical shells is presented. The differential equations of motion are solved directly with the use of simple Fourier series as the modal displacement functions. Stokes' transformation is exploited to obtain correct series expressions for the derivatives of the Fourier series. From this method an explicit expression of the exact frequency equation can be obtained for any kind of boundary conditions. The accuracy of the present method is checked against available data. The proposed method is then used to find the modal characteristics of the thermal liner of the Fast Test Reactor (FTR). The numerical results obtained are compared with finite element method solutions. (auth)
1975-07-01
International Nuclear Information System (INIS)
Using standards on phenol-formaldehyde resin base for assaying-activation analysis of geological specimens for gold and silver has bee the advantage of uniformly distributing Au and Ag in spesimens and possible preparing tablets of practically any form or size. The validity and accuracy of these standards have been studied for the cases of short irradiation. Conventional point standards were used as reference standards. The experiments carried out have shown that tablet resol standards are suitable for a mass assaying-activation analysis for gold and silver at practically any concentrations.
Transient behaviour of solar heated radiation receivers for small gas turbine power plants
Energy Technology Data Exchange (ETDEWEB)
Solar heating of gas turbine plants steps back more and more into the focus of current research. The mainly instationary operation of solar turbine power plants can only be predicted with sufficient accuracy if the transient behaviour of the receiver for the solar radiation is known. Therefore the transient behaviour of cavity receivers of different design is investigated. The mathematical model used for the simulation of the heat transfer and energy storage processes is illustrated. Computed results for receivers with various inner lining are compared and evaluated concerning their use in practice.
1987-03-01
Transient behavior of solar heated radiation receivers for small gas turbine power plants
Energy Technology Data Exchange (ETDEWEB)
Solar heating of gas turbine plants is moving back to the focus of current research. The mainly unsteady operation of solar turbine power plants can only be predicted with sufficient accuracy if the transient behavior of the solar radiation receiver is known. Therefore the transient behavior of cavity receivers of different designs is investigated. The mathematical model used to simulate heat transfer and energy storage is illustrated. Computed results for two receivers with different inner lining are compared and evaluated concerning their use in practice.
1987-01-01
Torsion of moderately thick hollow tubes with polygonal shapes
British Library Electronic Table of Contents (United Kingdom)
A simple formulation is presented for torsion analysis of hollow tubes with polygonal shapes. Thicknesses of segments of cross section can be different. Governing equations in term of Prandtl's stress function are used to derive the formulas. The derived formulas are so simple that computations can be carried out with a pocket calculator. Several examples are presented to show the accuracy and efficiency of the formulation. The obtained results are verified by accurate finite element solutions. It will be seen that the derived formulas can be useful for analysis of thin-walled and moderately thick-walled hollow tubes.
2007-01-01
Tolerance limits of X-ray image intensity
International Nuclear Information System (INIS)
Evaluation of the tolerance limits of X-ray image density accepted by the radiologist shows that for different kinds of examinations, deviations of more than 50% from optimal density lead to images which cannot be used diagnostically. Within this range diagnostic accuracy shows a distinct maximum and diminishes to the limits by 20%. These figures are related to differences in the intensifying factor of screens, sensitivity of films, sensitometric parameters of film processing as well as the doses employed with automatic exposure control devices, measured in clinical conditions. Maximum permissible tolerance limits of the whole imaging system and of its constituents are discussed using the Gaussian law of error addition. (author).
Thermodynamic Model of Aluminum Combustion in SDF Explosions
Energy Technology Data Exchange (ETDEWEB)
Thermodynamic states encountered during combustion of Aluminum powder in Shock-Dispersed-Fuel (SDF) explosions were analyzed with the Cheetah code. Results are displayed in the Le Chatelier diagram: the locus of states of specific internal energy versus temperature. Accuracy of the results was confirmed by comparing the fuel and products curves with the heats of detonation and combustion, and species composition as measured in bomb calorimeter experiments. Results were fit with analytic functions u = f(T) suitable for specifying the thermodynamic properties required for gas-dynamic models of combustion in explosions.
2006-06-19
Solution of the orthopositronium lifetime puzzle
The intrinsic decay rate of orthopositronium formed in SiO/sub 2/ powder is measured using the direct 2 gamma correction method such that the time dependence of the pick-off annihilation rate is precisely determined. The decay rate of orthopositronium is found to be 7.0396+or-0.0012(stat.)+or-0.0011(sys.)/ mu s/sup -1/, which is consistent with our previous measurements with about twice the accuracy. Results agree well with the O( alpha /sup 2/) QED prediction, and also with a result reported very recently using nanoporous film.
2004-01-01
SNAP sky background at the north ecliptic pole
Energy Technology Data Exchange (ETDEWEB)
I summarize the extant direct and indirect data on the sky background SNAP will see at the North Ecliptic Pole over the wavelength range 0.4 < {lambda} < 1.7 {micro}m. At the spatial resolution of SNAP the sky background due to stars and galaxies is resolved, so the only source considered is zodiacal light. Several models are explored to provide interpolation in wavelength between the broadband data from HST and COBE observations. I believe the input data are now established well enough that the accuracy of the sky background presented here is sufficient for SNAP simulations, and that it will stand up to scrutiny by reviewers.
2002-07-01
Rigid muffin-tin approximation for the electron-phonon interaction in transition metals
Energy Technology Data Exchange (ETDEWEB)
Progress in calculating the electron-phonon parameters of transition metals has been based on either the rigid muffin-tin approximation (RMTA) or the fitted modified tight-binding approximation (FMTBA). The RMTA has been shown to be remarkably accurate for average electron-phonon properties, but there are indications that RMTA matrix elements may be too small at low momentum transfer. An attempt is made to demonstrate these assertions concerning the accuracy of RMTA and the numerous electron-phonon calculations are placed in a broader perspective by a demonstration of how they can be used to explain the trends in the strength of the electron-phonon coupling among the transition metals and the A-15 compounds. (GHT)
1980-01-01
International Nuclear Information System (INIS)
At the importance increase of UT (ultrasonic testing) with the application of rules on fitness-for-service for nuclear power plants, JAPEIC (Japan power engineering and inspection corporation) started education training for defect detection and sizing technique. Weld joints specimen with EDM (Electro-Discharged Machining) notches, fatigue cracks and intergranular stress corrosion cracks were tested and practiced repeatedly based on a modified ultrasonic method and the defect size measuring accuracy of the trainees was surely improved. Results of the blind test confirmed effectiveness of education training. (T. Tanaka)
2005-04-01
Residual water losses during determination of total water content in brown coal
Energy Technology Data Exchange (ETDEWEB)
Discusses Czechoslovak regulations for determining moisture content in brown coal. Standard formulae for determining total moisture content and residual water content are described. Factors that influence accuracy in determining moisture content under laboratory conditions are analyzed: brown coal type, season of the year, air humidity, method and duration of coal sample drying, number of coal samples simultaneously dried in 1 dryer, ash content of coal. On the basis of analysis recommendations for a modified method of determining moisture content in brown coal are made. 5 refs.
1988-01-01
Reliable dates for the last 50.000 years; Des dates fiables pour les 50 000 dernieres annees
Energy Technology Data Exchange (ETDEWEB)
The accuracy of the carbon 14 dating method is dependent on the fluctuations of carbon 14 in the atmosphere over long periods of time. Fossil corals that are dated by both carbon 14 and uranium-thorium methods allows the setting of calibration curves for the carbon 14 method for the last 50.000 years. The uranium-thorium method is based on the measurement of the ratio of 2 isotopes: thorium 230 and uranium 234 that are both present in the decay chain of uranium 238. (A.C.)
2004-03-01
Pricing barrier options by a regime switching model
British Library Electronic Table of Contents (United Kingdom)
This paper introduces a new way of estimating parameters in a Brownian motion regime switching asset model to incorporate volatility clustering. The regime switching model is then applied to pricing of up-and-in barrier call options. We take the probability of crossing the barrier between simulation points into account, and we increase accuracy in simulations by importance sampling. The regime switching model is compared to the Normal Inverse Gaussian model and the traditional Black-Scholes model, and option prices from the regime switching model are compared to the closed form expression of up-and-in barrier calls in a Black-Scholes market.
2011-01-01
Ovarial tumours in the CT image - correlation of histology and CT diagnosis
Energy Technology Data Exchange (ETDEWEB)
The value of CT in respect of preoperative determination of tumour status and of tumour classification was studied using 127 histologically identified ovarial tumours as basis in a blind study via mutual image classification by the two participating institutes. The medium accuracy of diagnosis was 82%, but the results were found to be greatly dependent on tumour histology. Quotas of more than 90% were obtained in case of functional cysts, cystomas, cystadeno-carcinomas and dermoids, whereas classification was less successful with the other types of tumours such as germ cell tumours, tumours of the sexually differentiated stroma, metastases and tubo-ovarial abscesses.
1984-04-01
On Cost Estimate for Decommissioning of one Isotope Central
International Nuclear Information System (INIS)
The main scope of this study has been to calculate the future cost for decommission and dismantling the Isotope central at the Studsvik site using the OMEGA CODE. Detailed empirical information is used in the study for 'bench-marking' purposes, in such cases when there is a need to supplement and correct field data from the industry. In the present study, data has been retrieved and organized such that the estimated costs for decommissioning of the Isotope Central become transparent and reliable. This approach gives a preliminary qualitative indication about the accuracy of the cost estimate delivered by the industry
1994-04-25
International Nuclear Information System (INIS)
A non-linear mathematical model of dynamics of horizontal steam generator for nuclear power unit with WWER type reactor is presented. To realize this model the GEMMA-120 simulation language for computer Odra-1204 has been used. Necessity of taking into account disposited thermal storage capacities along tubulation of a primary cycle is demonstrated. A number of lumped elements of reactor division against a required static accuracy of calculations has been determined. (author).
1977-01-01
Non-gravitational perturbations and satellite geodesy
Energy Technology Data Exchange (ETDEWEB)
This book presents the basic ideas of the physics of non-gravitational perturbations and the mathematics required to compute their orbital effects. It conveys the relevance of the different problems that must be solved to achieve a given level of accuracy in orbit determination and in recovery of geophysically significant parameters. Selected Contents are: Orders of Magnitude of the Perturbing Forces, Tides and Apparent Forces, Tools from Celestial Mechanics, Solar Radiation Pressure-Direct Effects: Satellite-Solar Radiation Interaction, Long-Term Effects on Semi-Major Axis, Radiation Pressure-Indirect Effects: Earth-Reflected Radiation Pressure, Anisotropic Thermal Emission, Drag: Orbital Perturbations by a Drag-Like Force, and Charged Particle Drag.
1987-01-01
Energy Technology Data Exchange (ETDEWEB)
This paper presents a new method for the determination of the energy gap of superconductors. The V/sub max//kT versus ..delta../kT curve was calculated from tunneling theory. The maximum voltage in differential conductance V/sub max/ was measured from the electron tunneling spectrum. From V/sub max//kT and the curve, one can easily calculate the energy gap value ..delta... This method is simple, and the accuracy almost approaches that of the curve-fitting method.
1986-07-01
International Nuclear Information System (INIS)
This paper presents a new method for the determination of the energy gap of superconductors. The V/sub max//kT versus #DELTA#/kT curve was calculated from tunneling theory. The maximum voltage in differential conductance V/sub max/ was measured from the electron tunneling spectrum. From V/sub max//kT and the curve, one can easily calculate the energy gap value #DELTA#. This method is simple, and the accuracy almost approaches that of the curve-fitting method.
Energy Technology Data Exchange (ETDEWEB)
A new method for determining the energy gap of a superconductor using the maximum in the differential conductance curve of electron tunneling spectrum is given in this paper. The V/sub max//kT versus ..delta../kT curve was calculated from tunneling theory. V/sub max/, the voltage of the conductance maximum, can be measured from electron tunneling spectrum. ..delta../kT can be found from this curve, then the energy gap ..delta.. can be calculated. This method is simple, fast and accurate. The accuracy almost approaches that of the curve fitting method.
1986-02-01
Neural network for prediction of superheater fireside corrosion
Energy Technology Data Exchange (ETDEWEB)
Superheater corrosion causes vast annual losses to the power companies. If the corrosion could be reliably predicted, new power plants could be designed accordingly, and knowledge of fuel selection and determination of process conditions could be utilized to minimize superheater corrosion. If relations between inputs and the output are poorly known, conventional models depending on corrosion theories will fail. A prediction model based on a neural network is capable of learning from errors and improving its performance as the amount of data increases. The neural network developed during this study predicts superheater corrosion with 80 % accuracy at early stage of the project. (orig.) 10 refs.
1998-12-31
International Nuclear Information System (INIS)
The global effect of activation cross-section uncertainties on calculated radiological quantities is investigated for the first time using a methodology based on Monte Carlo random sampling. The method is applied to the calculation of the uncertainty in the contact dose rate from the gunite shielding of the National Ignition Facility chamber after 30 yr of pulsed irradiation. Some critical cross section contributing significantly to the overall uncertainty are identified. By a reasonable reduction of the uncertainty in those cross sections, the accuracy in the calculated total contact dose rate is greatly improved.
2003-05-01
Method of determining migrational bitumoids
Energy Technology Data Exchange (ETDEWEB)
This invention refers to the organic geochemistry and can be used in prospecting for oil and gas. The method includes taking samples of rocks, extracting from them the chloroform bitumoid and its thermal processing. In order to improve the accuracy, the equal quantities of bitumoid taken are exposed to gradual thermal treatment to temperatures exceeding the thresholds of thermal stability of sulfur-containing compounds, in each temperature interval, the content of hydrogen sulfide released in this case is revealed, and by its drastic increase at temperatures corresponding to the temperatures of the productive part of the section, a conclusion is drawn about the epigenetic nature of the bitumoid. The method makes it possible to improve the resolution of the bituminological prospecting for oil and gas.
1982-01-01
Measurement of low-energy laser pulse duration in femtosecond range
International Nuclear Information System (INIS)
Measurements of low-energy (#approx#10"- "1"0 J) femtosecond laser pulse durations have been carried out on the basis of second-order autocorrelation function analysis. The scheme of non collinear second harmonic generation realized in KDP crystal has been used for increasing of the measurement contrast and accuracy. Proposed scheme can be used for measurements in wide enough ranges of laser pulse durations (from tens femto seconds to hundreds picoseconds) and energies. (authors)
Investigation of subsurface exploration methods for prevailing geologic conditions in South Carolina
Subsurface conditions at sites in the coastal plains region of South Carolina were investigated using standard penetration and mechanical quasi-static cone penetration tests. The penetration test results are compared with measured static axial pile capacity. The cone penetration test results are compared with stratigraphy and soil types encountered at each site. Results show that with certain limitations, cone penetration test results can be used to assess general stratigraphy and soil type and predict static axial pile capacity with reasonable accuracy.
1985-11-01
Focusing and resonance properties of two-dimensional small-size hemielliptic lenses made of different materials are studied numerically in order to estimate the influence of internal reflections on the radiation characteristics of dielectric lens antennas. Accuracy of in-house made algorithms based on combination of geometrical and physical optics and FDTD in the analysis of optical and modal effects in the behavior of such lenses is tested by comparison with the exact solution obtained using the Muller boundary integral equations. The range of applicability for the approaches is discussed.
2010-01-01
Input modelling for subchannel analysis of CANFLEX fuel bundle
Energy Technology Data Exchange (ETDEWEB)
This report describs the input modelling for subchannel analysis of CANFLEX fuel bundle using CASS(Candu thermalhydraulic Analysis by Subchannel approacheS) code which has been developed for subchannel analysis of CANDU fuel channel. CASS code can give the different calculation results according to users' input modelling. Hence, the objective of this report provide the background information of input modelling, the accuracy of input data and gives the confidence of calculation results. (author). 11 refs., 3 figs., 4 tabs.
1998-06-01
Innovative active control of gun barrels using smart materials
The accuracy of stabilized, turreted gun systems like the 120mm gun on the M1A2 Abrams tank and the 30mm gun on the Apache helicopter are limited by, among other things, structural flexure of the gun barrel and support structure. An advanced actuation system based on piezoelectric translators and an optical fiber strain sensing system are described in conjunction with a rapid prototyping workstation for the design of distributed parameter control systems to actively minimize the effects of vibrations caused by traversing rough terrain or weapon firing.
1997-06-01
Heating of magneto-rheological fluid dampers: a theoretical study
This paper focuses on a theoretical model that predicts the temperature increase of Magneto-rheological (MR) fluid dampers experiencing a sinusoidal input motion. A theoretical model is developed to estimate the temperature rise based on the non-linear behavior of the MR fluid damper. This model is solved numerically, and the numerical solution is compared with a known linear solution and experimental result in order to validate the accuracy of the model. Also, a non-dimensional form of the governing equations are developed to examine the key parameters. The non-dimensional terms show the effect of external and internal parameters on the trends of heat dissipation as well as heat generation within the MR fluid damper.
1999-05-01
Heat generation of magneto-rheological fluid dampers
This study presents a theoretical analysis of heat generation and dissipation of field-controllable magneto-rheological fluid (MRF) shock absorbers. Since MRF dampers are energy- dissipating devices, the issues of heat generation and dissipation are important in predicting their performance. A theoretical model is developed based on Bingham plastic model to estimate temperature history of the MRF dampers. The governing equation includes the MRF viscosity as a function of the temperature. The numerical solutions are compared with experimental results in order to validate the accuracy of the model, and excellent agreements are obtained.
2000-04-01
Fission rate assessments in FFTF using passive techniques
Energy Technology Data Exchange (ETDEWEB)
Fission rate assessments are being made in FFTF to provide input for determination of power distribution, peak power, total power, fuel burnup distribution, conversion ration and neutron spectral information by the multiple foil reaction rate method. A goal of the initial FFTF Characterization Program is to measure isotopic fission rates to an accuracy of 2 to 5% throughout FFTF by radiometric techniques. To achieve this goal, measurements were made in the FFTF In-Reactor Thimble to reduce the uncertainties of key parameters needed for radiometric fission rate mapping of the FFTF core.
1981-10-01
Error evaluation of the linearized equation of servo valve in hydraulic control systems
International Nuclear Information System (INIS)
In the procedure of the hydraulic control system analysis, a linearized approximate equation described by the first order term of Taylor's series has been widely used. Such a linearized equation is effective just near the operating point. In this study, the authors estimate computational errors in the process of applying the existing linearized equation stated above. For evaluating the computational accuracy in practical applications of the linearized equations, dynamic behaviors of hydraulic control systems are investigated through simulations with several kinds of representative hydraulic systems and the linearized equations suggested in this study.
2001-11-01
The effects of variable hardness, pH, alkalinity, humics, and suspended clay on the chemical speciation of copper and its toxicity to fathead minnow larvae in Lake Superior water were investigated. Two proposed methods (toxicity factors and chemical speciation) for predicting LC50 values in specific natural waters from laboratory toxicity data and the average site specific values of general water quality parameters were evaluated. The accuracy of the cupric ion-selective electrode in determining CU/sup +2/ activities in ambient and chemically altered Lake Superior water was also determined.
1986-03-01
Dynamic analysis of Darrieus vertical axis wind turbine rotors
The dynamic response characteristics of the VAWT rotor are important factors governing the safety and fatigue life of VAWT systems. The principal problems are the determination of critical rotor speeds (resonances) and the assessment of forced vibration response amplitudes. The solution to these problems is complicated by centrifugal and coriolis effects which can have substantial influence on rotor resonant frequencies and mode shapes. This paper will describe and discuss the primary tools now in use at Sandia National Laboratories for rotor analysis. These tools include a lumped springmass model (VAWTDYN) and also finite-element based approaches. The discussion will center on the accuracy and completeness of current capabilities and plans for future research.
1981-01-01
Dynamic analysis of Darrieus vertical axis wind turbine rotors
The dynamic response characteristics of the vertical axis wind turbine (VAWT) rotor are important factors governing the safety and fatigue life of VAWT systems. The principal problems are the determination of critical rotor speeds (resonances) and the assessment of forced vibration response amplitudes. The solution to these problems is complicated by centrifugal and Coriolis effects which can have substantial influence on rotor resonant frequencies and mode shapes. The primary tools now in use for rotor analysis are described and discussed. These tools include a lumped spring mass model (VAWTDYN) and also finite-element based approaches. The accuracy and completeness of current capabilities are also discussed.
1981-05-01
Distribution amplitudes of {sigma} and {lambda} and their electromagnetic form factors
Energy Technology Data Exchange (ETDEWEB)
Based on QCD conformal partial wave expansion to leading order conformal spin accuracy, we present the light-cone distribution amplitudes (DAs) of {sigma} and {lambda} baryons up to twist 6. It is concluded that fourteen independent DAs are needed to describe the valence three-quark states of the baryons at small transverse separations. The nonperturbative parameters relevant to the DAs are determined within the framework of QCD sum rule method. With the obtained DAs, a simple investigation on the electromagnetic form factors of these baryons are given. The magnetic moments of the baryons are estimated by fitting the magnetic form factor with the dipole formula.
2009-04-15
Energy Technology Data Exchange (ETDEWEB)
The authors have developed a complex of activation methods of analysis using a nuclear reactor (nuclear activation analysis) and a cyclotron (charged-particle activation analysis). The methods have been used to determine the concentrations of more than 20 elements in five medicinal plants native to Uzbekistan: Syrian rue (Peganum harmala L.), plantain (Plantago lanceolata), peppermint (Mentha piperata L.), sage (Salvia officinalis L.), and ziziphora (Ziziphora bungeana Yur.). The results of radio-activation analysis were compared with the results of standard spectral analysis performed in another laboratory and the accuracy of the procedures developed was evaluated on the basis of the results.
1987-06-01
Energy Technology Data Exchange (ETDEWEB)
This study of the inorganic chemical composition of 10 different Nigerian medicinal plant species, using the technique of instrumental neutron activation analysis (INAA), resulted in the determination of the concentrations of 18 major, minor, and trace elements: Al, Ba, Br, Ca, Cl, Eu, Fe, Ga, K, La, Mn, Na, Sb, Sc, Si, Sm, V, and Zn. The parts of the plants used were roots, leaves, and bark. The NBS SRM 1571 Orchard Leaves was also analyzed to assess the accuracy of the procedures used. 21 refs., 4 tables.
1984-04-02
Energy Technology Data Exchange (ETDEWEB)
Discusses methods for determining ash content in coal using backscattering in X-ray fluorescence. The following aspects are evaluated: principle of ash content determination, energy sources, factors that influence measurement accuracy, reliability. Types of X-ray fluorescence analyzers developed in Czechoslovakia and manufactured in the Czech Republic are comparatively evaluated. Operation of the RPM 113.1 radionuclide X-ray fluorescence analyzer developed by the PAR company and used for measuring ash content in coal and coal calorific value is discussed. 7 refs.
1993-09-01
Computer-aided diagnosis of bone tumours and tumour-like skeletal abnormalities in childhood
Energy Technology Data Exchange (ETDEWEB)
The method, use and results of computer-aided diagnosis of bone tumours and tumour-like skeletal abnormalities in childhood are described. One hundred and twentyone histologically verified cases were analysed and subjected to computer-aided diagnosis. Statistical methods were used, resulting in an accuracy of 96.7% and 91.7% respectively. In order to obtain additional confirmation of the diagnosis, a so-called growth rate was calculated by the computer. This proved to be a reliable criterion for evaluating the biological behaviour of tumours, irrespective of the histological diagnosis. The reasons for misdiagnosis were discussed. Attention is drawn to the importance of an accurate analysis of the radiographs and its input into the computer.
1982-06-01
Energy Technology Data Exchange (ETDEWEB)
As an application of ART2 neural networks, computer aided monitoring of pump efficiency is successfully examined for an industrial waste-liquid treatment process with measured data of valve openness and liquid flow rates. By running the neural networks in parallel, we confirm that accuracy to detect system changes is good, and the adjustment of classifier parameters is relatively easy. Investigating the resulting classes carefully, frequency of each class is correlated with pump efficiency. The relative amount of variables are also related to the classes. (author)
2000-05-10
Coherent $\\omega$ photoproduction from nuclei and $\\omega$ properties in nuclear matter
The coherent $\\omega$-meson photoproduction from nuclei is proposed as a phenomenological method to evaluate the momentum dependence of $\\omega$-meson mass shift and width in nuclear matter. We analyze available data on un-separated coherent and incoherent $\\omega$-meson photoproduction from nuclei and extract the imaginary part of the the complex forward $\\omega{N}$ scattering amplitude, which is proportional to the in-medium $\\omega$-meson width. The accuracy of the currently available data is not sufficient to evaluate the real part of forward $\\omega{N}$ scattering amplitude and reconstruct the momentum dependence of the mass shift of the $\\omega$-meson.
2002-01-01
Choice of energies in gamma-absorption method for layers thickness measuring of two-layers articles
International Nuclear Information System (INIS)
Empirical formulae are proposed for the description of relation between optimum energies minimizing the mean-weighted error of gamma absorption measurement of the thickness of layers in two-layer products with the thickness of every layer from 30 up to 150 mm by carbon. Error of informational parameter approximation with the application of tables does not exceed 10% in case of non-accurate assessment of layers thickness not exceeding 2.5%. Generalized equation is derived which binds main parameters of the task and permits to choose optimum energies with the accuracy sufficient for practical purposes
Energy Technology Data Exchange (ETDEWEB)
Calibration system for spot welding robots has been developed. The purpose of this system is to reduce the misalignment of tool center point (TCP) generated when teaching data made by off-line system is input to an actual robot. After the factor of the misalignment was analyzed, the relation between a main factor and the misalignment was modeled. In addition, the model was verified on experiment. The achievement of the accuracy requirement and practical use in the site was confirmed by the result of the verification. (author)
1999-04-01
Alignment accuracy of focused ion beam implantation
Energy Technology Data Exchange (ETDEWEB)
The theoretical alignment limit for focused ion beam (FIB) implantation was deduced from the calculated resolution for the detection of an alignment mark. The alignment resolution varies with the signal to noise ratio and there is an optimum current which gives the best resolution. The alignment resolution epsilon/sub sigma/ is approximately 0.006 ..mu..m for a 160 keV Si/sup ++/ beam from our FIB implanter. The measured alignment error is approximately 0.06 ..mu..m and the main reason of this discrepancy is vibration. The ultimate limit on the alignment error can be reached through improvements in the implanter system.
1987-06-01
International Nuclear Information System (INIS)
During one year more than 40,000 items of information on radiation exposure of personnel involved in the handling of radiation sources and more than 5,000,000 items on irradiation of other people are collected in the authors' laboratory. Considerable progress in assessment of mean annual gonad dose of genetically sifnificant dose was attained by means of an algorithm for a personal computer. This simple and inexpensive system has led to a higher accuracy in the application of protective measures. (author).
1985-10-22
Advantages and limitations of the SETS method. [PWR; BWR
Energy Technology Data Exchange (ETDEWEB)
The stability-enchancing two-step (SETS) method has been used successfully in the Transient Reactor Analysis Code (TRAC) for several years. The method consists of a basic semi-implicit step combined with a stabilizer step that, taken together, eliminate the material Courant stability limit associated with standard semi-implicit numerical methods. This approach toward stability requires significantly fewer computational operations than a fully implicit method, but currently maintains the first-order accuracy in space and time of its semi-implicit predecessors.
1983-01-01
International Nuclear Information System (INIS)
Instrumental neutron activation analysis is used for simultaneously determination of macrocomponents in ferroelectric materials LLZT. Pb, Zr, Ti have been determined by "2"0"3Pb, "8"9Zr and "4"8Sc nuclides created by fast neutron (14.5 MeV) activation. Application of paraffine as neutron moderator and reflector allows to simultaneously determine lanthanum by "1"4"0La nuclide. It has been shown that zirconium, titanium and lanthanum can be determined with the accuracy of #+-#0.1 mas. % and lead - #+-#0.7 mas. %.
International Nuclear Information System (INIS)
With the advent of intensity-modulated radiation therapy (IMRT), the inclusion of heterogeneity corrections is further complicated by the conformal delivery of many small beams forming steep dose gradients. Radiation treatment planning has evolved to take into account even small changes in tissue density so that the dose to tumor can be further optimized. However, different treatment planning systems incorporate different heterogeneity correction algorithms, and it is unclear whether any of these algorithms are superior to others in terms of accurately predicting delivered radiation doses relative to measurement in a clinical setting. The purpose of this study was to determine the accuracy of heterogeneity dose calculations from two widely used IMRT treatment planning systems (Pinnacle and Corvus) against measurement. These two systems handle heterogeneity dose corrections by means of a collapsed-cone convolution superposition algorithm and a finite-size ...
2007-05-01
APSIS - an Artificial Planetary System in Space to probe extra-dimensional gravity and MOND
A proposal is made to test Newton's inverse-square law using the perihelion shift of test masses (planets) in free fall within a spacecraft located at the Earth-Sun L2 point. Such an Artificial Planetary System In Space (APSIS) will operate in a drag-free environment with controlled experimental conditions and minimal interference from terrestrial sources of contamination. We demonstrate that such a space experiment can probe the presence of a "hidden" fifth dimension on the scale of a micron, if the perihelion shift of a "planet" can be measured to sub-arc-second accuracy. Some suggestions for spacecraft design are made.
2006-01-01
A navigation filter for fusing DTM/correspondence updates
An algorithm for pose and motion estimation using corresponding features in images and a digital terrain map is proposed. Using a Digital Terrain (or Digital Elevation) Map (DTM/DEM) as a global reference enables recovering the absolute position and orientation of the camera. In order to do this, the DTM is used to formulate a constraint between corresponding features in two consecutive frames. The utilization of data is shown to improve the robustness and accuracy of the inertial navigation algorithm. Extended Kalman filter was used to combine results of inertial navigation algorithm and proposed vision-based navigation algorithm. The feasibility of this algorithms is established through numerical simulations.
2011-01-01
Preoperative staging of rectal carcinoma with combined sonography and pelvic computed tomography
International Nuclear Information System (INIS)
The accurate staging of rectal carcinoma is very important for treatment planning. The histological data obtained from surgical specimens of 22 patients with rectal carcinoma were compared with pre-and postoperative endorectal US findings and with preoperative CT results. According to an adapted version of Astler and Coller classification, the different degrees of tumor spread into the rectal wall were represented as follows: stage A: 1 patient; stage B1: 5 patients; stage B2: 6 patients; stage C1: 1 patient; stage C2: 8 patients and stage D: 1 patient. Preoperative staging, based on the overall results of CT and US, was in agreement with histology in 19 of 22 cases. Individual analysis of US and CT results, in comparison with histological data, showed US staging accuracy to be 77.3% (17/22 patients). US accuracy in demonstrating tumor spread into the rectal wall (stages A, B1, C1) was 100% (7/7 patients); US was 70% accurate in lymph node ...
1991-01-01
International Nuclear Information System (INIS)
The Anisotropic Analytical Algorithm (AAA) is a new pencil beam convolution/superposition algorithm proposed by Varian for photon dose calculations. The configuration of AAA depends on linear accelerator design and specifications. The purpose of this study was to investigate the accuracy of AAA for an Elekta SL25 linear accelerator for small fields and intensity modulated radiation therapy (IMRT) treatments in inhomogeneous media. The accuracy of AAA was evaluated in two studies. First, AAA was compared both with Monte Carlo (MC) and the measurements in an inhomogeneous phantom simulating lung equivalent tissues and bone ribs. The algorithm was tested under lateral electronic disequilibrium conditions, using small fields (2x2 cm"2). Good agreement was generally achieved for depth dose and profiles, with deviations generally below 3% in lung inhomogeneities and below 5% at interfaces. However, the effects of attenuation and scattering close to ...
2007-05-01
Energy Technology Data Exchange (ETDEWEB)
To compare the accuracy of MR imaging using an endorectal-pelvic and a pelvic phased-array coil for preoperative local staging of rectal carcinoma. To determine preoperative staging, 38 patients with rectal carcinoma underwent MR imaging. All patients were examined with both an endorectal-pelvic and a pelvic phased-array coil. All underwent surgery and staging was pathologically confirmed. Two radiologists blinded to pathologic stage analyzed perirectal invasion and perirectal node metastasis, and scored according to a four-point scale. Radiologic and pathologic findings were correlated. Receiver operating characteristic (ROC) analysis of Wilcoxon statistic (W values) was used to compare diagnostic accuracy between the two different MR methods. Interobserver variation was measured using {kappa} statistics. For perirectal invasion, T1WI endorectal-pelvic phased-array coil images (reader 1:0. 854, reader 2:0.818) showed higher W values than ...
1998-10-01
International Nuclear Information System (INIS)
The effects of extended source-to-surface distance (SSD) on the electron beam dose profiles were evaluated for various electron beam energies - 6, 9, 12, 15 and 20 MeV - and the accuracy of various output correction methods was analysed on a Mitsubishi linear accelerator using a radiation field analyser (RFA). The dose fall-off region of the central axis depth-dose curves was nearly independent for SSDs up to 120 cm where as in the build-up region, a marginal reduction of surface dose was observed, particularly for lower energies and for smaller field sizes. Effective SSDs and virtual source distances were evaluated for field sizes ranging from 5x5 to 15x15 cm"2 for various energies. Curve fitting was done with the measured outputs with various equations and coefficients were evaluated. The accuracy of the derived output correction factors by effective SSD, virtual source distance and curve-fit methods was assessed by evaluating correlation ...
2002-09-21
International Nuclear Information System (INIS)
The purpose of this study is to develop a geometrically accurate imaging protocol at 3 T magnetic resonance imaging (MRI) for stereotactic radiosurgery (SRS) treatment planning. In order to achieve this purpose, a methodology is developed to investigate the geometric accuracy and stability of 3 T MRI for SRS in phantom and patient evaluations. Forty patients were enrolled on a prospective clinical trial. After frame placement prior to SRS, each patient underwent 3 T MRI after 1.5 T MRI and CT. MR imaging protocols included a T1-weighted gradient echo sequence and a T2-weighted spin echo sequence. Phantom imaging was performed on 3 T prior to patient imaging using the same set-up and imaging protocols. Geometric accuracy in patients and phantoms yielded comparable results for external fiducial reference deviations and internal landmarks between 3 T and 1.5 T MRI (mean ?0.6 mm; standard deviation ?0.3 mm). Mean stereotactic reference deviations ...
2010-11-21
Clinical MR mammography. Impact of hormonal status on background enhancement and diagnostic accuracy
Energy Technology Data Exchange (ETDEWEB)
Purpose: Hormonal stimulation can induce background enhancement (BE) in MR mammography (MRM). This fact has been assumed to decrease the accuracy of MRM. Consequently, this report investigates: 1. The prevalence of BE in postmenopausal vs. premenopausal women in correlation to hormonal cycle phase (CP). 2. The impact of hormonal status (HS) and BE on diagnostic accuracy. Materials and Methods: Consecutive patients over 22 months with complete HS information (week of CP or postmenopausal) were included in this prospective investigation. Exclusion criteria were any hormonal therapy, hysterectomy as well as cancer proven by biopsy. The standard of reference was histopathology. All MRM scans were acquired using the same protocol (1.5 T, dynamic T 1w GRE after 0.1 mmol/kg bw Gd-DTPA i. v.). Two radiologists rated all examinations in consensus according to BI-RADS. BE was defined as: 0 = missing, 1 = moderate, 2 = distinct. Results: 224 patients (150 ...
2011-05-15
Energy Technology Data Exchange (ETDEWEB)
To assess whether ring enhancements of liver metastases on Mn-DPDP enhanced, early MR images were well visualized on delayed images, as compared with those of hepatocellular carcinomas (HCC), and to investigate the detection accuracy and conspicuity of each tumor. Twenty patients with liver metastases and 15 with HCC were studied by Mn-DPDP enhanced, T1-weighted MR images. Peripheral ring enhancement and conspicuity were investigated. Differences in detection accuracy and frequency of ring enhancement in liver metastases and HCC were assessed. In liver metastases (n= 69), 44 cases (63.8%) without ring enhancement and 25 (36.2%) with were noted on early images. Sixteen cases (23.2%) without ring enhancement, 38 (55.1%) with ring enhancement similar to the early images, and 15 (21.7%) with prominent ring enhancement were noted on delayed images. In HCC (n=37), 36 cases (97.3%) without ring enhancement and 1 case (2.7%) with were noted on early ...
2004-09-01
Energy Technology Data Exchange (ETDEWEB)
Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experimental aberrations (intensity fluctuations and inaccuracy in the correction for spectral efficiency of a detection system), 2) inaccuracy in theoretical parameters used for ...
2007-12-15
International Nuclear Information System (INIS)
Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experimental aberrations (intensity fluctuations and inaccuracy in the correction for spectral efficiency of a detection system), 2) inaccuracy in theoretical parameters used for ...
2007-12-01
Development of High Field Dipole and High Current Pulse Power Supply for Compact Proton Synchrotron
Development of High Field Dipole and High Current Pulse Power Supply for Compact Proton Synchrotron
2003-01-01
Energy Technology Data Exchange (ETDEWEB)
Acute thoracic aortic injuries account for up to 10-20% of fatalities in high-speed deceleration road accidents and have an estimated immediate fatality rate of 80-90%. Untreated survivors to acute trauma (10-20%) have a dismal prognosis: 30% of them die within 6 hours, 40-50% die within 24 hours, and 90% within 4 months. It was investigated the diagnostic accuracy of Helical Computed Tomography (Helical CT) in acute traumatic injuries of the thoracic aorta, and the role of this technique in the diagnostic management of trauma patients with a strong suspicion of aortic rupture. It was compared retrospectively the chest Helical CT findings of 256 trauma patients examined June 1995 through August 1999. Chest Helical CT examinations were performed according to trauma score, to associated traumatic lesions and to plain chest radiographic findings. All the examinations were performed with no intravenous contrast agent administration and the pitch 2 ...
2000-09-01
Energy Technology Data Exchange (ETDEWEB)
To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI scanner (Magnetom Avanto, Siemens Medical Solutions) with a ...
2004-09-01
DoseWatchers - A computer based X ray dose monitoring project in paediatric radiology
International Nuclear Information System (INIS)
Full text: Introduction. Children, especially premature infants and neonates, are at a much higher risk to obtain an X ray induced disturbance of life - particularly cancer. On the one hand this is due to their longer life expectancy and on the other hand it is due to their higher cell proliferation rate. The paediatric radiology unit of the Inselspital Bern recently installed some of the most advanced X ray equipment nowadays available. It is based on the two latest digital technologies: double read computed radiography (CR) and direct digital radiography (DR). Only the implementation of these digital radiography systems permits the digital acquisition and additionally the analysis of acquired data. The systematic analysis of large amounts of biometric data and exposition data is the basis for further dose reduction and a systematic quality control (QC). Patients are increasingly critical concerning radiation exposure - especially parents regarding their children. Besides an ...
2006-11-13
High Purity Beryllium Production
International Science & Technology Center (ISTC)
Production of High-Purity (>99.99% wt.) Condensed Beryllium
Fabrication of an infrared bolometer with a high T$_{c}$ superconducting thermometer
Fabrication of an infrared bolometer with a high T$_{c}$ superconducting thermometer
1991-01-01
Single Molecule Source Reagents for CVD of Beta Silicon Carbide.
Beta silicon carbide is an excellent candidate semiconductor material for demanding applications in high power and high temperature electronic devices due to its high breakdown voltage, relatively large band gap, high thermal conductivity and high melting...
1991-01-01
Use of a point-of-care beta-hydroxybutyrate sensor for detection of ketonemia in dogs.
The urine test strip is the most common test used to detect ketones in veterinary patients, but it can underestimate the degree of ketonuria and hence, ketonemia. Additionally, adequate urine samples for analysis may be difficult to obtain from dehydrated animals. The standard method used to detect and monitor ketonemia in human medicine is measurement of serum or whole blood beta-hydroxybutyrate (?HOB). A point-of-care (POC) analyzer has been validated for this purpose in humans. This study compared the accuracy of the POC device to an enzymatic reaction laboratory method for measurement of ?HOB in dogs. Although the POC sensor tended to overestimate ?HOB concentrations, there was good correlation (R(2) = 0.96) and good agreement between the 2 methods with a bias +/- precision of 0.0860 +/- 0.3410 mmol/L ?HOB. The POC ?HOB sensor can be useful for assessing ketonemia in dogs. PMID:21119867
2010-09-01
Two years of flight of the Pamela experiment: results and perspectives
PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range (protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antinuclei with a precision of the order of $10^{-8}$). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, $15^{th}$ 2006 in a $350\\times 600 km$ orbit with an inclination of 70 degrees. In this work we describe the scientific objectives and the performance of PAMELA in its first two years of operation. Data on protons of trapped, secondary and galactic nature - as well as measurements of the December $13^{th}$ 2006 Solar Particle Event - are also provided.
2008-01-01
The optimization of gamma spectra processing in prompt gamma neutron activation analysis (PGNAA)
International Nuclear Information System (INIS)
The uncertainty of the elemental analysis is one of the major factors governing the utility of on-line Prompt Gamma Neutron Activation Analysis (PGNAA) in the blending and sorting of bulk materials. In this paper, a general method applicable to Gamma spectra processing is presented and applied to PGNAA in mineral industry. Based on the Fourier transform of spectra and their de-correlation in the Fourier space (the improvement of the conditioning of the correlation matrix), processing of overlapping of characteristic peaks minimizes the propagation of random errors, which optimizes the accuracy and decreases the detection limits of elemental analyses. In comparison with classical methods based on the linear combinations of relevant regions of spectra the improvement may be considerable, especially when several elements are interfering. The method is applied to four case stories covering both borehole logging and on-line analysis on conveyor belt of raw materials.
2009-04-15
The kinematics of coronal mass ejections using multiscale methods
The diffuse morphology and transient nature of coronal mass ejections (CMEs) make them difficult to identify and track using traditional image processing techniques. We apply multiscale methods to enhance the visibility of the faint CME front. This enables an ellipse characterisation to objectively study the changing morphology and kinematics of a sample of events imaged by the Large Angle Spectrometric Coronagraph (LASCO) onboard the Solar and Heliospheric Observatory (SOHO) and the Sun Earth Connection Coronal and Heliospheric Investigation (SECCHI) onboard the Solar Terrestrial Relations Observatory (STEREO). The accuracy of these methods allows us to test the CMEs for non-constant acceleration and expansion. We exploit the multiscale nature of CMEs to extract structure with a multiscale decomposition, akin to a Canny edge detector. Spatio-temporal filtering highlights the CME front as it propagates in time. We apply an ellipse parameterisation of the front to ...
2009-01-01
Using the complex Kohn method, we have calculated variational values of phase shifts and the annihilation parameter, Z_{eff}, for the elastic scattering of positrons by molecular hydrogen. Our results are sensitive to small changes in the accuracy of the wave function representing the target hydrogen molecule. We have developed a systematic approach to demonstrate that, at low positron energies, there are particular forms of the Kohn trial wave function for which the results of variational calculations are not reliable, even when the target wave function accounts for as much as 96.8% of the correlation energy of H_{2}. We find that reliable results can be recovered if our calculations are extended to admit more sophisticated target wave functions accounting for 99.7% of the correlation energy. Remaining discrepancies between theory and experiment are briefly discussed.
2008-01-01
Spherical redshift distortions
Peculiar velocities induce apparent line of sight displacements of galaxies in redshift space, distorting the pattern of clustering in the radial versus transverse directions. On large scales, the amplitude of the distortion yields a measure of the dimensionless linear growth rate \\ff of fluctuations, which is related to the cosmological density \\Omega and the linear bias factor b in linearly biassed standard cosmology by \\ff \\approx \\Omega^{0.6} /b. To make the maximum statistical use of the data in a wide angle redshift survey, and for the greatest accuracy, the spherical character of the distortion needs to be treated properly, rather than in the simpler plane parallel approximation. In the linear regime, the redshift space correlation function is described by a spherical distortion operator acting on the true correlation function. It is pointed out here that there exists an operator, which is essentially the logarithmic derivative with respect to pair ...
1995-01-01
Simple calculation of daily photosynthesis by means of five photosynthesis-light equations
Energy Technology Data Exchange (ETDEWEB)
The performance of five well-known photosynthesis-light equations is compared by presenting a wide range of solutions in the form of dimensionless nomographs for the case where photosynthetically available radiation (PAR) reduces exponentially down the water column and is distributed sinusoidally through the photoperiod. These provide a simple means of calculating daily photosynthesis at any depth (e.g. at a benthic layer), or through a water column, avoiding the need to perform complex integrations. An examination is made of the accuracy of common approximate methods for calculating daily photosynthesis, assuming constant PAR. For optically deep water a modification is proposed to Talling's planimetric solution, to enable daily photosynthesis to be calculated more accurately, yet simply, over the whole range of possible PAR values. The errors induced by approximating the daily PAR distribution as a half-sinusoid are also reported. 13 refs., 9 figs., 5 ...
1992-12-01
Screening Samples with a Position-Sensitive Detection System Providing Isotope-Specific Information
International Nuclear Information System (INIS)
The properties of individual radioactive particles present in a sample, such as a swipe, are more interesting than bulk properties of the sample. The present work focuses on instrumentation that provides position-sensitive spectral information non-destructively from the sample. The experimental part of the work was realized using a device called PANDA (Particles And Non-Destructive Analysis). The detector setup used in the study contains a broad-energy HPGe gamma-ray detector and a position-sensitive alpha detector. Both detectors are connected to a time-stamping event-mode data acquisition system. The method is shown to locate particles with sub-millimetre accuracy and distinguish the interesting particles from non-interesting ones. (author)
2010-11-01
Proton Form Factors measurements in the time-like region
Energy Technology Data Exchange (ETDEWEB)
I present an overview of the measurement of the proton form factors in the time-like regiun. BABAR has recently measured with great accuracy the e{sup +} e{sup -} {yields} p p-bar reaction from productiun threshold up to an energy of {approx} 4.5 GeV; finding evidence for a ratio of the electric to magnetic form factur greater than unity, contrary to expectation. In agreement with previous measurements. BABAR confirmed the steep rise uf the magnetic form factor close to the p p-bar mass threshold, suggesting the possible presence of an under-threshuld N N-bar vector state. These and uther open questiuns related to the nucleon furm factors both in the time-like and space-like region, wait for more data with different experimental techniques to be possibly solved.
2007-05-15
Prediction of agrochemical residue data on fruit using an informatic system (PARDIS model)
British Library Electronic Table of Contents (United Kingdom)
A `step-by-step' method was used to develop a simplified procedure for calculating pesticide residue levels on fruit at harvest by considering the application of the compound and the relevant routes of loss. The model is applicable to cases where the most important exposure route is by direct spray to the canopy of the crop and where uptake into the plant by the roots can be disregarded. The exposure dose is calculated by considering the proportion of total crop cover represented by the fruits. The loss processes considered are photodegradation, uptake, volatilization and washoff. The outputs of the model were compared with measured residues of pesticides on pear. Analysis of the model fit demonstrates that the model predicted the measured data with a good level of accuracy for four of sev...
2008-01-01
British Library Electronic Table of Contents (United Kingdom)
In vibration control field, magneto-rheological (MR) fluid dampers are semi-active control devices that have recently begun to receive more attention. This paper presents a nonlinear black-box model (BBM) and an inverse black-box model (IBBM) for the identification of a MR fluid damper and their application to design a novel force-sensorless control method for any damping system using that damper. The nonlinear model named 'black-box' is a simple direct modeling method which was designed based on fuzzy-neural technique. Characteristics of the damper in study are directly estimated through a fuzzy mapping system. In order to improve the model accuracy, neural network technique including back-propagation and gradient descent method were used to train the fuzzy parameters to minimize the mode...
2011-01-01
New pulse sequence for simultaneous T1, T2, and RHO determination in whole-body proton MR imaging
International Nuclear Information System (INIS)
A newly developed method to support tissue characterization in routine MR imaging is presented. It represents a compromise between the practical requirements of clinical routine (short measurement time, multisection imaging) and the necessary accuracy of the relaxation parameter evaluation. The sequence employed is a modification of the PHAPS technique and works with two excitation pulses. It allows the simultaneous acquisition of all measurement data for the subsequent T1, T2, and rho evaluations. T1 is determined with a specially designed computation formula based on four signal ratios. A multiexponential T2 analysis is performed with use of 28 echoes. From these parameters, relative proton density can be computed.
International Nuclear Information System (INIS)
This article reviews the principal evidences about aluminum neurotoxicity in vitro, and some evidences in brain tissues of Alzheimer patients; and also show some studies realized with human that suffer renal deficiencies, dealing whit the principal osteodystrophy. The problem of analyzing low aluminum concentration in human fluids is overcome with very sensitive analytical methods as electrothermal atomic absorption spectrometry (ETAS) and voltammetric methods as Anodic Striping Voltammetry with complexing agents that easing adsorption over solid electrodes or mercury hanging drops. Is a vital question to know with accuracy the aluminum concentration in water used in hemodialysis or in fluids used in ambulatory peritoneal dialysis, as a first stage to prevent contamination by aluminum. So the prevention of contamination during sapling storage and analysis of biological fluids should be the first need and the sources of water used in renal dialysis keep be as clean ...
2001-01-01
Interpolating atmospheric water vapor delay by incorporating terrain elevation information
British Library Electronic Table of Contents (United Kingdom)
In radio signal-based observing systems, such as Global Positioning System (GPS) and Interferometric Synthetic Aperture Radar (InSAR), the water vapor in the atmosphere will cause delays during the signal transmission. Such delays vary significantly with terrain elevation. In the case when atmospheric delays are to be eliminated from the measured raw signals, spatial interpolators may be needed. By taking advantage of available terrain elevation information during spatial interpolation process, the accuracy of the atmospheric delay mapping can be considerably improved. This paper first reviews three elevation-dependent water vapor interpolation models, i.e., the Best Linear Unbiased Estimator in combination with the water vapor Height Scaling Model (BLUE?+?HSM), the Best Linear Unbiased Es...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Experiences with the model parameter identification of the excitation system (EXS) and the power system stabilizer (PSS) for Mingtan{number_sign}6 pumped storage generation unit of Taiwan Power System are presented in this paper. The input-output data corresponding to each block of the EXS and PSS were obtained when the finalization tests of this unit were performed. The generalized least squares (GLS) approach is introduced and employed to identify the desired parameters of the noisy excitation system and PSS models. In this method, the reduction technique of biased estimates due to the non-white (correlated) identification residual is also applied to improve the accuracy of identification. The results of the parameter estimation are satisfactory. The GLS parameter identification method using the measured data at finalization tests is then suggested from the viewpoint of economy and engineering.
1995-05-01
British Library Electronic Table of Contents (United Kingdom)
In vibration control field, magneto-rheological (MR) fluid dampers are semi-active control devices that have recently begun to receive more attention. This paper presents a black-box model (BBM) for identification of a MR fluid damper and its application to vibrating control systems using that damper with self-sensing behavior. A model named ''black-box'' is a simple direct modeling method which is designed for a typical MR fluid damper using the self-tuning fuzzy technique. The characteristics of the researched damper are directly estimated through a fuzzy mapping system. In order to improve the accuracy of the proposed model, the back propagation algorithm and gradient descent method were used to train the fuzzy parameters to minimize the model error function. Consequently, the BBM with ...
2010-01-01
Geospatial tools for assessing land degradation in Budgam district, Kashmir Himalaya, India
British Library Electronic Table of Contents (United Kingdom)
Land degradation reduces the ability of the land to perform many biophysical and chemical functions. The main aim of this study was to determine the status of land degradation in the Budgam area of Kashmir Himalaya using remote sensing and geographic information system. The satellite data together with other geospatial datasets were used to quantify different categories of land degradation. The results were validated in the field and an accuracy of 85% was observed. Land use/land cover of the study area was determined in order to know the effect of land use on the rate of land degradation. Normalized differential vegetation index (NDVI) and slope of the area were determined using LANDSAT-enhanced thematic mapper plus (ETM+) data, advanced space borne thermal emission and reflection radiome...
2011-01-01
From Whitney Forms to Metamaterials: a Rigorous Homogenization Theory
A rigorous homogenization theory of metamaterials -- artificial periodic structures judiciously designed to control the propagation of electromagnetic waves -- is developed. All coarse-grained fields are unambiguously defined and effective parameters are then derived without any heuristic assumptions. The theory is an amalgamation of two concepts: Smith & Pendry's physical insight into field averaging and the mathematical framework of Whitney-Nedelec-Bossavit-Kotiuga interpolation. All coarse-grained fields are defined via Whitney forms and satisfy Maxwell's equations exactly. The new approach is illustrated with several analytical and numerical examples and agrees well with the established results (e.g. the Maxwell-Garnett formula and the zero cell-size limit) within the range of applicability of the latter. The sources of approximation error and the respective suitable error indicators are clearly identified, along with systematic routes for improving the ...
2010-01-01
Field results using measurement-while-drilling directional systems in Long Beach, California
Energy Technology Data Exchange (ETDEWEB)
One of the more extensive uses of directional drilling anywhere in the world has been in the development of the East Wilmington Oil Field in Long Beach, California. The Measurement-While-Drilling (MWD) directional system has been tested on several wells and proven to provide the required accuracy, along with many advantages over past methods, used in the field development. Accurate transmission by MWD of bottom-hole measurements to the surface is provided by mud pressure pulses generated in the drill pipe downhole and detected by a pressure transducer includes the means for detecting, recording and processing these pressure pulses, to translate the information from the pressure pulses to rig floor displays usable by the drilling crew. 2 refs.
1981-01-01
Evaluation on codes to estimate the number of failed rods using Korean PWR activity data
International Nuclear Information System (INIS)
The coolant activity analysis to obtain the information about the fuel failure has been studied long before. And several codes have been developed to estimate the number of fuel failures through evaluating volatile and inert fission products release in coolant from the defective fuel. These codes use a fission product diffusion model coupled with a mass balance in the gap and coolant. But each code has a different model to assess fuel failure. In order to develop the model to estimate the number of fuel failures we analysis well-known code's models such as CHIRON, CADE, IODYNE, and CAAP and compare accuracy through Korean PWR activity data
2010-10-01
Electron-impact excitation of Si"3"+(3s#->#3p) using a merged-beam electron-energy-loss technique
International Nuclear Information System (INIS)
For the first time, absolute cross sections for electron-impact excitation of a multiply charged ion have been measured using an electron-energy-loss technique. Cross sections for e+Si"3"+(3s "2S_1_/_2)#->#e+Si"3"+(3p "2P_1_/_2_,_3_/_2)-8.88 eV have been measured with an accuracy of #+-#20% (at 90% confidence level) over a narrow energy range (#+-#0.6 eV) about the threshold energy with an energy resolution of 0.2 eV. Results are in good agreement with close-coupling calculations.
Energy Technology Data Exchange (ETDEWEB)
Incomplete convergence in numerical simulation such as computational physics simulations and/or Monte Carlo simulations can enter into the calculation of the objective function in an optimization problem, producing noise, bias, and topo- graphical inaccuracy in the objective function. These affect accuracy and convergence rate in the optimization problem. This paper is concerned with global searching of a diverse parameter space, graduating to accelerated local convergence to a (hopefully) global optimum, in a framework that acknowledges convergence uncertainty and manages model resolu- tion to efficiently reduce uncertainty in the final optimum. In its own right, the global-to-local optimization engine employed here (devised for noise tolerance) performs better than other classical and contemporary optimization approaches tried individually and in combination on the "industrial" test problem to be presented.
1999-05-18
Dynamic analysis of Darrieus vertical axis wind turbine rotors
Energy Technology Data Exchange (ETDEWEB)
The dynamic response characteristics of the VAWT rotor are important factors governing the safety and fatique life of VAWT systems. The principal problems are the determination of critical rotor speeds (resonances) and the assessment of forced vibration response amplitudes. The solution to these problems is complicated by centrifugal and Coriolis effects which can have substantial influence on rotor resonant frequencies and mode shapes. This paper will describe and discuss the primary tools now in use at Sandia National Laboratories for rotor analysis. These tools include a lumped spring-mass model (VAWTDYN) and also finite-element based approaches. The discussion will center on the accuracy and completeness of current capabilities and plans for future research. As this paper is meant primarily to provide an overview, much of the detail is omitted and will be presented in a follow-on report.
1981-05-01
Determination of Proper Peaking Time for Ultra Lege detector at Medium Energies
International Nuclear Information System (INIS)
Reducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the optimum peaking time for particular detector systems is important. For this purpose, pure Se and Zn elements were excited by 59.5 keV ?-rays from a 50 mCi 241Am annular radioactive source in this study. The characteristic x-rays emitted from pure Se and Zn elements were detected by using an ultra low energy Ge (Ultra-LEGe) detector connecting Tennelec TC 244 spectroscopy amplifier at different peaking time modes. Overall pulse widths were determined by HM 203-7 oscilloscope connecting amplifier. The proper peaking time for ultra low energy germanium detector (Ultra-LEGe) is determined about 4 ?s.
2008-08-25
Constraining Parity Violation in Gravity with Measurements of Neutron-Star Moments of Inertia
Neutron stars are sensitive laboratories for testing general relativity, especially when considering deviations where velocities are relativistic and gravitational fields are strong. One such deviation is described by dynamical, Chern-Simons modified gravity, where the Einstein-Hilbert action is modified through the addition of the gravitational parity-violating Pontryagin density coupled to a field. This four-dimensional effective theory arises naturally both in perturbative and non-perturbative string theory, loop quantum gravity, and generic effective field theory expansions. We calculate here Chern-Simons modifications to the properties and gravitational fields of slowly spinning neutron stars. We find that the Chern-Simons correction affects only the gravitomagnetic sector of the metric to leading order, thus introducing modifications to the moment of inertia but not to the mass-radius relation. We show that an observational determination of the moment of inertia to an ...
2009-01-01
Computational Relativistic Astrophysics With Adaptive Mesh Refinement: Testbeds
We have carried out numerical simulations of strongly gravitating systems based on the Einstein equations coupled to the relativistic hydrodynamic equations using adaptive mesh refinement (AMR) techniques. AMR coalescences of neutron stars can now be simulated with sufficient resolution covering the neutron stars while having the computational domain extend to the local wave zone. We show an AMR simulation carried out with a workstation having an accuracy equivalent to that of a 1025^3 regular uni-grid simulation, which is, to the best of our knowledge, larger than all previous simulations of similar NS systems on supercomputers. We believe the capability opens new possibilities in general relativistic simulations.
2005-01-01
Energy Technology Data Exchange (ETDEWEB)
A general purpose Emergency Generator Set (EGS) is considered for a methodological study and related reliability behavior is analyzed. In particular in a procedure of reliability and availability analysis of a EGS, dependent failure events need a complex mathematical model as state-space model to be a accurately evaluated. Furthermore these dependent failure events are one of the most important reliability characteristic of EGS. This paper suggests a procedure for reliability calculations in presence of dependent failure based on the evaluation of a equivalent failure rate that can be fitted to a network reduction method by simple mathematical calculations. The simplified models analyzed show a good accuracy for a wide range of variation of main reliability characteristics of EGS and utility. The advantages obtained are very useful on reliability evaluation because the possibility of use of network approach provides a shorter route to calculation and it is ...
1995-12-31
Clinical application of dosimetry in electron beam therapy
International Nuclear Information System (INIS)
In everyday radiotherapy we must carry out the determination of absorbed dose measurement according to JARP's protocol. We explained an outline of JARP's 1974 and 1986 protocol in electron beam therapy, and mentioned it about the matter that should examined. To use it easily in clinic, a simplified procedure based on precisely to JARP's 1986 protocol is practical, the character of this procedure settles briefly the determination of mean incident energy of electron beams and get ready to table of ionization to absorbed dose conversion factor for various ionization chamber. Also, this procedure almost not influence on the accuracy of determination. We described systematically practical procedure for requisite absorbed dose calculation in a patient in electron beam therapy. (author).
Benchmarking Declarative Approximate Selection Predicates
Declarative data quality has been an active research topic. The fundamental principle behind a declarative approach to data quality is the use of declarative statements to realize data quality primitives on top of any relational data source. A primary advantage of such an approach is the ease of use and integration with existing applications. Several similarity predicates have been proposed in the past for common quality primitives (approximate selections, joins, etc.) and have been fully expressed using declarative SQL statements. In this thesis, new similarity predicates are proposed along with their declarative realization, based on notions of probabilistic information retrieval. Then, full declarative specifications of previously proposed similarity predicates in the literature are presented, grouped into classes according to their primary characteristics. Finally, a thorough performance and accuracy study comparing a large number of similarity predicates for ...
2009-01-01
Bayesian estimation of mixed Weibull distributions
Energy Technology Data Exchange (ETDEWEB)
Estimation of mixed Weibull distribution by maximum likelihood estimation and other methods is frequently difficult due to unstable estimates arising from limited data. Bayesian techniques can stabilize these estimates through the priors, but there is no closed-form conjugate family for the Weibull distribution. This paper reduces the number of numeric integrations required for using Bayesian estimation on mixed Weibull situations from five to two, thus making it a more feasible approach to the typical user. It also examines the robustness of the Bayesian estimates under a variety of different prior distributions. It is found that Bayesian estimation can improve accuracy over the MLE for situations with low mixture ratios so long as the prior on the weak subpopulation's characteristic life has an expected value less than or equal to the true characteristic life.
2009-02-15
Automation in urinalysis: evaluation of three urine test strip analysers.
A clinical laboratory evaluation was conducted on the Clinitek Auto 2000, the Super Aution Analyzer and the Urotron RL9 for the determination of glucose, protein, pH, blood, ketone-bodies and bilirubin.Precision of the systems was tested using three commercial control urine materials, and reported as the percentage of times the instrument repeats a certain value. Good repeatability was obtained with all the instruments.Accuracy of the systems was evaluated by comparison with quantitative procedures, and to check agreement between methods yielding semi-quantitative and quantitative results, ranges of acceptability were defined, based on the criteria reported in a previous paper [2]. It was then found that 87.5 to 98.9% of results from the Urotron RL9 and the Clinitek Auto 2000 were acceptable. With the Super Aution Analyzer the level of agreement was apparently lower because of the higher number of concentration steps used by this instrument. PMID:18925198
1988-01-01
Articulated tool provides flexibility, accuracy and lower costs
Energy Technology Data Exchange (ETDEWEB)
A new German-engineered articulated drilling tool that can take the vertical to the horizontal, using about eight metres of curve, was described. The Articulate Downhole Motor has the capability to run radii as long as 57 metres (the usual requirement is 15 metres), under full control. Its ability to rotate and slide while maintaining control is one of the major positives of the technology. The technology also includes a `positive` communication system in its steering tool. The deployment of the positive pulse retrievable measurement-while-drilling (MWD) system brings real-time tool face orientation and hole direction to the surface. In using the tool, formation composition is not an issue; it is designed to withstand any environment.
1996-12-01
A new Nitrogen Index to evaluate nitrogen losses in intensive forage systems in Mexico
British Library Electronic Table of Contents (United Kingdom)
Although nitrogen inputs to agricultural fields are necessary for global food sustainability, they present a major nutrient management challenge, because nitrogen inputs can increase nitrogen losses to the environment, which can negatively impact water quality across key surface and groundwater resources. The need to evaluate the potential risk of nitrogen losses for a given forage type, management scenario, and field quickly and easily can be met with new tools that assist in environmental risk assessment. An example is the Mexico Nitrogen Index: this new tool aims to help its users quickly evaluate the risk of nitrogen loss for a given field under a given set of management practices. The objective of this study was to evaluate the accuracy of the Mexico Nitrogen Index in ranking the risk...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
A thermal-electric mathematical model for a squirrel cage induction motors which permits to specify the best motor for specific drive, under thermal and electric aspects based, only on manufacturer technical bulletins and technical information is presented. Changes of rotor parameters due Skin Effect and changes of winding resistances (both stator and rotor) with the temperature are considered. The accuracy of this model is appraised using experimental results. The thermal behavior and electric performance for some motors are obtained for continuos and intermittent duties with sinusoidal and non-sinusoidal voltages. (author)
1992-03-01
A VUV prism spectrometer for RICH radiator refractometry
A prism spectrometer has been developed to operate in the VUV wavelength range from 120 to 200 nm. It can be used as a pre- disperser in conjunction with a Fabry-Perot based gas refractometer. This instrument has also been used to measure the refractive index of the liquid radiator C/sub 6/F/sub 14/ in various spectral lines. This radiator is used in the RICH detectors of the DELPHI experiment and has been proposed for ALICE, and LHCb experiments. The spectral resolution of the system is improved as the wavelength decreases and the data are consistent with a wavelength accuracy about 0.4 nm at 140 nm. The results for the dispersion curve of the above liquid are presented. (17 refs).
2000-01-01
A Network Coding Approach to Loss Tomography
Network tomography aims at inferring internal network characteristics based on measurements at the edge of the network. In loss tomography, in particular, the characteristic of interest is the loss rate of individual links. There is a significant body of work dedicated to this problem using multicast and/or unicast end-to-end probes. Independently, recent advances in network coding have shown that there are several advantages from allowing intermediate nodes to process and combine, in addition to just forward, packets. In this paper, we pose the problem of loss tomography in networks that have network coding capabilities. We design a framework for estimating link loss rates, which leverages network coding capabilities and we show that it improves several aspects of tomography, including the identifiability of links, the tradeoff between estimation accuracy and bandwidth efficiency, and the complexity of probe path selection. We discuss the cases of inferring: the ...
2010-01-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
