The specific heat consumption and the loss mechanisms at the nozzle-group regulation of steam turbines; Zum spezifischen Waermeverbrauch und den Verlustmechanismen bei der Duesengruppenregelung von Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

The nozzle-group regulation of steam turbines plays furtheron an important role in the operation of power stations owing to modern, adaptable control-technical valve timing possibilities. New procedures for a choice-connection of different nozzle areas via the control valves as well as the use of valve laps require, however, a differentiated consideration of the loss mechanism in the inlet area of the turbine, in order to be able to assess and minimize its specific heat consumption also at the operational points outside the layout- and calculation-technically fixed guarantee or valve points, respectively. The basic technical-physical stages to this are explained. (orig.) [Deutsch] Die Duesengruppenregelung von Dampfturbinen nimmt nicht zuletzt dank moderner, anpassungsfaehiger leittechnischer Ventilansteuerungsmoeglichkeiten weiterhin eine bedeutende Stellung beim Betrieb von Kraftwerken ein. Neue Verfahren zur wahlweisen Zuschaltung unterschiedlicher Duesenflaechen ueber die ...

1995-07-01

2

Phenomenological modelling of heat transfer at the gas side wall of diesel engines; Phaenomenologische Modellbildung des gasseitigen Wandwaermeueberganges in Dieselmotoren  

Energy Technology Data Exchange (ETDEWEB)

A phenomenological model of the heat transfer in direct injection diesel engines was developed. Utilizing the thermodynamic results of a combustion model as an input, the model is able to predict the temporal variation of the heat losses from the cylinder gas to the cylinder walls. Additionally, the division into isothermal combustion chamber subsurfaces allows the consideration of the spatial variation of the wall heat fluxes. The physical mechanisms such as flow dependent convection, heat radiation due to hot soot particles and isolation effects of deposited soot layers are described in detail. Thus the effects of these mechanisms on the overall heat transfer can be studied. The heat transfer model was verified successfully by the comparison to measured wall heat fluxes in a single-cylinder direct injection diesel engine. It is shown that the effects of engine speed and load, turbocharging and soot deposition can be predicted with good accuracy. [German] Es wurde ein ...

2000-07-01

3

The new WHO classification of brain tumors. Radiological aspects of 4 new tumor entities; Die revidierte WHO-Klassifikation der Hirntumoren. Radiologische Aspekte unter besonderer Beruecksichtigung von vier neuen Tumorentitaeten  

Energy Technology Data Exchange (ETDEWEB)

Characterisation of the classification of brain tumours authorised by the WHO. Method of appraisal: This classification was revised and published in its second version. In the revision, some tumours were regrouped histogenetically and some tumour variants were added. Radiologically relevant changes of the classification include the differentiation of four new tumour entities that are easily distinguished by MR imaging. These four tumours belong to the group of childhood tumours or tumours occurring in early adulthood and are characterized by a good prognosis after extirpation. Results of appraisal: Central neurocytomas are small-cyst ventricular tumours associated with the foramen of Monroi and show moderate contrast enhancement. Infantile desmoplastic gangliogliomas/astrocytomas commonly consist of a solid tumour portion related to the leptomeninges with pronounced contrast enhancement and a typically very large cyst. Pleomorphic xanthostrocytomas are circumscribed cortical tumours ...

1997-06-01

4

3D MRI of the colon: methods and first results of 5 patients; 3D-MRT des Kolons: Methodik und erste Ergebnisse  

Energy Technology Data Exchange (ETDEWEB)

Purpose: `Exoscopic` and endoscopic identification of colorectal pathologies via MRI. Methods: 5 patients (36-88 years), two normal and three with different colorectal pathologies (diverticular disease, polyps and carcinoma of the colon), were examined by MRI after colonoscopy. Subsequent to filling of the colon with a gadolinium-water mixture under MRI-monitoring, 3D-data sets of the colon were acquired in prone and supine positions over a 28 sec breathold interval. Subsequently multiplanar T{sub 1}-weighted 2D-sequences were acquired before and following i.v. administration of Gd-DTPA (0.1 mmol/kg BW). All imaging was performed in the coronal orientation. The 3D-data were interactively analysed based on various displays: Maximum intensity projection (MIP), surface shadowed display (SSD), multiplanar reconstruction (MPR), virtual colonoscopy (VC). Results: All of the colorectal pathologies could be interactively diagnosed by MPR. On MIP images some pathologies were missed. VC ...

1997-09-01

5

Investigation of respiratory-dependent movements of pulmonary space-occupying lesions with MRI; Untersuchung der atemabhaengigen Bewegungen pulmonaler Raumforderungen mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Parallel imaging and echo sharing techniques have markedly reduced the acquisition times for MRI of large volumes. Dynamic 2 and 3-dimensional data sets of the chest with high temporal resolution (up to 10 images/s with single slice and 2 volume/s) allow an analysis of respiratory motion of the lungs and tumors. Time-resolved 2D series in preselected planes can be used to observe respiratory motion during free breathing or after respiratory commands, e.g. to exclude chest wall invasion by a tumor or for diagnosing impairment of respiratory mechanics. Time-resolved 3D-series (4D-MRI) allow monitoring of the spatial displacement of the lungs and tumors as a whole volume. Present limitations such as an overestimation of tumor size and an underestimation of displacement due to a limited temporal resolution are expected to be overcome with further technical developments. However, 4D-MRI already appears to be the appropriate tool to select patients for motion-adapted radiotherapy. In ...

2009-08-15

6

Observation and control of hepatic specimens with MRI and MRS; Beobachtung und Kontrolle von Fixiervorgaengen in Leberpraeparaten mittels MRT und MRS  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The purpose of this study was to observe the process of fixation in liver specimens non-invasively by means of magnetic resonance. The fixation process of several formaldehyde-containing solutions was monitored with MRI and MRS at two different temperatures. Materials and Methods: Liver specimens were conserved in aqueous fixative solutions containing formaldehyde concentrations of 0.7, 1.8, 4 and 7.2% and at different temperatures of 5 C and 20 C. MRI was performed with T1-, T2- and PD-weighted TSE sequences, a 2D FLASH-sequence with and without magnetization transfer, and a FISP 3D-sequence on a clinical 1.5 Tesla MR whole-body unit, and MRS with {sup 1}H-spectroscopic methods (STEAM-sequence) on a 3 Tesla MR whole-body unit. Results: The diffusion of formaldehyde into the tissue was best identified on PD- and T1-weighted images as a band under the liver surface with increasing thickness, penetrating especially fast during the first three days. Spectroscopic measurements ...

2004-04-01

7

Comparison of high resolution whole-body MRI using parallel imaging and PET-CT. First experiences with a 32-channel MRI system; Hochaufloesendes Ganzkoerpertumorstaging unter Verwendung paralleler Bildgebung im Vergleich zur PET-CT. Erste Erfahrungen auf einem 32-Kanal-MRT-System  

Energy Technology Data Exchange (ETDEWEB)

To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI scanner (Magnetom Avanto, Siemens Medical Solutions) with a total field of view of 205 cm and free table movement, all ...

2004-09-01

8

Investigation of dominant loss mechanisms in low-temperature polymer electrolyte membrane fuel cells  

Energy Technology Data Exchange (ETDEWEB)

This thesis deals with the analysis of dominant loss mechanisms in direct methanol fuel cells (DMFC) and hydrogen fed polymer electrolyte membrane fuel cells (PEFC) by means of experimental characterization and modeling work. Due to different fuels used in these two fuel cell types, the dominant loss mechanisms are different in their nature. All in-situ characterization techniques that are used in this work are based on a novel test fuel cell with embedded reference electrodes. The first part of this work presents a new concept for realizing a reference electrode configuration in a polymer electrolyte membrane fuel cell by means of laser ablation. The laser beam is used to evaporate a small gap into the electrode surface of a catalyst coated membrane (CCM) to isolate the reference electrode from the working/counter electrode (WE/CE). This method enables the simultaneous ablation of the electrodes on both sides of the CCM because the membrane is transparent for the laser beam. ...

2010-07-01