North Slope of Alaska has huge oil deposits in heavy oil reservoirs such as Ugnu, West Sak and Shrader Bluff etc. The viscosity of the last two reservoir oils vary from {approx}30 cp to {approx}3000 cp and the amount in the range of 10-20 billion barrels. High oil viscosity and low formation strength impose problems to high recovery and well productivity. Water-alternate-gas injection processes can be effective for the lower viscosity end of these deposits in West Sak and Shrader Bluff. Several gas streams are available in the North Slope containing NGL and CO{sub 2} (a greenhouse gas). The goal of this research is to develop tools to find optimum solvent, injection schedule and well-architecture for a WAG process in North Slope shallow sand viscous oil reservoirs. In the last quarter, we have developed streamline generation and convection subroutines for miscible gas injection. The WAG injection algorithms are being developed. We formulated a ...
Fundamentals of economic evaluation of projects to produce electricity using geothermal energy are described. Steps to obtain the basic data used to calculate the present value and the internal rate of return are described. Finally, a criterion to make an economical evaluation to take the best investment selection is shown, applied to a geothermal project in the Los Azufres, field Michoacan, Mexico. [Espanol] En este articulo se describen los diferentes topicos que se desarrollan para llevar a cabo la evaluacion economica de un proyecto para generar electricidad, desde la recopilacion de datos hasta la obtencion de los indices necesarios para la toma de decisiones, y su aplicacion a un proyecto geotermoelectrico situado en el campo de Los Azufres, Michoacan, Mexico.
In this article the methodology followed to diagnose the performance of the equipment where heat is transferred from the feed water, condensate and circulation water systems in fossil power plants (FPP). The data collection is made with the unit in normal operation, using local instrumentation without taking the equipment out of service for its installation. The equipment diagnosis is made through the analysis of the collected data in actual operation and the design data; for this purpose a thermal balance of the interested systems is performed to obtain all the conditions an operation data. Later on the performance indicative parameters (PIP) of actual operation and design are calculated and compared one against the other. Such a comparison reveals the performance deterioration and the possible equipment faults. The data obtained and the supplementary information are stored in a data base whose objective is that Comision Federal de Electricidad has on hand a prompt access to them in ...