WorldWideScience
 
 
1

Computer aided monitoring of pump efficiency by using ART2 neural networks; ART2 nyurarunettowaku niyoru ponpuseino no rekka shindan shien  

Energy Technology Data Exchange (ETDEWEB)

As an application of ART2 neural networks, computer aided monitoring of pump efficiency is successfully examined for an industrial waste-liquid treatment process with measured data of valve openness and liquid flow rates. By running the neural networks in parallel, we confirm that accuracy to detect system changes is good, and the adjustment of classifier parameters is relatively easy. Investigating the resulting classes carefully, frequency of each class is correlated with pump efficiency. The relative amount of variables are also related to the classes. (author)

2000-05-10

2

Waste plastic treatment equipment; Hai plastic shori sochi  

Energy Technology Data Exchange (ETDEWEB)

In recent years, there has been increasing demand for resource-recycling of waste plastic, especially due to the introduction of legislation on recycling of materials used for packages of household goods. Methods of recycling waste plastic from household goods are currently still under development, and appropriate techniques to deal with such waste are required. Toshiba has developed a technique to dehydrochlorinate plastic containing polyvinyl chloride (PVC). This paper introduces our petrolization and dehydrochlorination system for waste plastic containing PVC. (author)

1999-04-01

3

Fault detection and fault diagnosis system for engine; Engine no kosho yochi shindan system  

Energy Technology Data Exchange (ETDEWEB)

The fault detection and diagnosis system for gas engines was developed to improve the reliability of cogeneration systems (CGS). Most of existing fault detection systems monitor the trend of each part condition of engines and diagnose faults based on trend change, resulting in slow detection. Although early detection systems are available, those are complex, expensive and poor in flexibility and applicability. Since CGSs combined with gas engines increased to 1/3 of the whole CGS, engine troubles cause possible serious faults. The fault diagnosis system was thus developed to prevent serious faults which can early detect, in particular, abnormal conditions of parts around a combustion chamber such as ignition plug, intake valve and exhaust valve by monitoring exhaust pressure waveforms in an exhaust collector. Since this system can detect progressive occurrence frequency of abnormal conditions and degradation of engine parts, it can transfer previous time management and preventive ...

1996-03-29

4

Application of wavelet analysis to signal processing methods for eddy-current test; ueburetto kaiseki no kadenryushinshoho heno tekiyo  

Energy Technology Data Exchange (ETDEWEB)

This study deals with the application of wavelet analysis to detection and characterization of defects from eddy-current and ultrasonic testing signals of a low signal-to-noise ratio. Presented in this paper are the methods for processing eddy-current testing signals of heat exchanger tubes of a steam generator in a nuclear power plant. The results of processing eddy-current testing signals of tube test pieces with artificial flaws show that the flaw signals corrupted by noise and/or non-defect signals can be effectively detected and characterized by using the wavelet methods. (author)

1998-12-15

5

Fuel processing equipment for fuel cell plant. Nenryo denchi plant no nenryo shori sochi  

Energy Technology Data Exchange (ETDEWEB)

Activated charcoal which is the desulfurizing agent for the fuel cell plant can be used only at the normal temperature, and it must be placed upstream of the fuel gas, increasing the displacement flow of the fuel gas processed in the desulfurizer. In addition, a large quantity of activated charcoal must be filled or the frequency of its exchange must be increased because activated charcoal used at the normal temperature has little sulfur absorbing capacity. This invention is concerned with provision of a desulfurizer in the downstream of the fuel gas compressor of the fuel cell plant to remove sulfur content in the fuel gas by this desulfurizer. As a result, the displacement flow of the processing gas is decreased to increase the processing capacity of the desulfurizing agent. In addition, hydrogen recycling can be eliminated to realize compact arrangement of the equipment and economization of energy consumption. Metal oxide based desulfurizers of copper, iron, zinc, manganese, etc. ...

1993-02-19

6

Demonstration test of power system stabilizer employing fuzzy theory; Fuzzy riron wo tekiyoshita keito anteika sochi o jissho shiken hokoku  

Energy Technology Data Exchange (ETDEWEB)

The demonstration test of a power system stabilizer, employing a fuzzy theory, in the two hydroelectric power stations of Kyusyu Electric Power Co., Inc. is described. The PSS inputs auxiliary signals to the automatic voltage regulator (AVR) of a generator and generates an electric torque in the direction opposite to the operating direction of a generator to enhance the damping effect and improve the system stability. Usually, the change in the slide information of a generator is detected, and the phase adjustment is performed so that the damping is the optimum value. However, since the damping is optimized in the specific system state, no complete damping may be obtained when the system state is changed. A fuzzy theory was thus applied for the control operation part. In a secondary fuzzy PSS, the velocity and acceleration were calculated from the slide information of a generator to produce a control signal. In the third dimension, moreover, the position (integral information of ...

1997-03-01

7

Analysis and evaluation for practical application of photovoltaic power generation system. Analysis and evaluation for thin substrate polycrystalline solar cells (alloy-base amorphous materials, PIN layers, strains in the interface, and effects of impurities); Taiyoko hatsuden system jitsuyoka no tame no kaiseki hyoka. Usumaku taiyo denchi jitsuyoka no tame no kaiseki hyoka (gokinkei amorphous zairyo pin kakuso kaimen ni okeru yugami fujunbutsu nado no eikyo)  

Energy Technology Data Exchange (ETDEWEB)

Described herein are the results of the FY1994 research program for analysis and evaluation for thin film solar cells. The study on quantitative analysis of hydrogen atoms in a plasma determines quantity of hydrogen atoms in the plasma of monosilane diluted with hydrogen. It is found, contrary to expectation, that quantity of hydrogen atoms in the plasma decreases as it is more diluted with hydrogen. The study on light-induced degradation of the thin chlorine-base amorphous silicon films confirms that the plasma CVD method with 20% of dichlorosilane gas added to monosilane gas produces the thin amorphous silicon film 3 times faster than the conventional method. The thin film has essentially the same defect density as the one prepared by the conventional method, showing good photoelectric characteristics. The thin film of chlorinated amorphous silicon has a 1 digit lower defect density than the conventional one of amorphous silicon, as revealed by the accelerated degradation test with ...

1994-12-01

8

HVDC power cable crossing Kii channel. Advanced technology to lay the submarine cable in two days; Kii suido wo yokogiru denryoku cable. Kaitei fusetsu wo futsuka de konasu shin`ei sochi  

Energy Technology Data Exchange (ETDEWEB)

Four HVDC (high voltage DC) {+-} 250kV submarine OF (oil-filled) cables are to be installed each capable of 1.4-million kW for one dipole channel and two returns for forwarding to Yura Switchyard a part of the power to be generated by a Tachibanawan coal-fired power plant to open in 2000. The first cable is now being laid. They are to cover a distance of 48km on the sea bottom, and their 190mm diameter is the largest in the world and this decreases the required number of cables for a reduction in the construction cost. The installation is executed by use of a dedicated cable laying ship loaded with cables. The ship is equipped with five thruster screws by adjusting which a cable is fed into the sea and laid on the bottom with high positional accuracy in all directions, and with a 10m-accurate DPS (Dynamic Positioning System) besides GPS (Global Positioning System). Operating on the sea bottom is a simultaneous laying/burying machine which buries the cable 2-3m deep in the sea bottom. ...

1998-07-01

9

Technique of moving picture overlapping for view simulation by means of the moving picture processing; Dogazo kaiseki ni motozuku keikan simulation no tame no dogazo goseiho  

Energy Technology Data Exchange (ETDEWEB)

This paper proposes a technique of moving picture overlapping for view simulation by means of the moving picture processing. The continuous pictures of actual natural view gotten from video and the pictures of building structure made by computer graphics (CG) were overlapped. The CG pictures of building structure model were made considering the camera parameters, such as position and direction of camera. In order to analyze the continuously changing camera parameters, optical flows were determined from the view video. Based on these results, the overlapping video was made, in which the building structure was incorporated into the actual view. Furthermore, the proposed technique of moving picture overlapping was applied to the view simulation of transmission line tower. Consequently, it was demonstrated that the overlapped moving pictures can provide information which can not be obtained from the still pictures. It was experimentally confirmed that the present technique is useful to ...

1994-11-01

10

Stability analysis of forced-flow cooled superconducting coil; Numerical simulation on multiple stability. Kyosei reikyaku gata chodendo coil no anteisei kaiseki; Taju anteisei no simulation  

Energy Technology Data Exchange (ETDEWEB)

The stability of a forced-flow cooled superconducting coil is investigated by use of the numerical simulation. The numerical code to integrate the simultaneous partial differential system composed of the 1 D hydrodynamic equations and the 1 D thermal conduction equation has been developed and stability margins are evaluated as functions of coolant mass flow rate, operation current and imposed magnetic field. The results of computations show that the stability margin is multi-valued with respect to these operation parameters, as expected from the experimental results. It is also shown that the appearance of the first unstable regime is closely related to the existance of the stagnant region located at the upstream side of the heated zone and that the second stable regime appears because the heat transfer is appreciably enhanced by the induced backflow due to the thermal expansion of coolant. 13 refs., 13 figs., 1 tab.

1990-06-25

11

Seismic tomography inversion in the case that sources and receivers are distributed out of a 2-D plane; Shingen jushinten ga nijigen heimennai ni nai baai no danseiha tomography kaiseki ni kansuru kosatsu  

Energy Technology Data Exchange (ETDEWEB)

In the case where sources and receivers are not distributed on a 2-D plane, seismic tomography inversion was studied. In tomography experiments, the existing wells are generally used. In such case, sources and receivers are frequently not distributed on a 2-D plane. The 2.5-D analysis method including 2-D structure and 3-D ray-tracing was thus developed. This method is featured by less memory necessary for ray-tracing calculation, and the same algorithm for velocity determination as 2-D analysis method. In previous methods, since analysis is generally carried out by projecting sources and receivers on a certain assumed 2-D plane, it can derive correct results in the case of constant velocity and straight ray, however, in the other case, it derives incorrect results. Application of 3-D tomography requires a large amount of memory, and falls into poor convergence because of various parameters. The 2.5-D analysis method can avoid these demerits. This analysis method was applied to the ...

1996-10-01

12

Seismic response of pile-supported structure considering nonlinearity of superstructure and pile, and liquefaction of surrounding ground; Shuhen jiban no ekijoka oyobi kui no hisenkeisei wo koryoshita kui shiji tatemono no jishin oto kaiseki  

Energy Technology Data Exchange (ETDEWEB)

Recent earthquake disasters have revealed the importance of countermeasures against soil Liquefaction in seismic design. In particular, the 1995 Hyogoken Nanbu earthquake caused several types of severe damages to pile foundations. This paper describes an analysis method for soil liquefaction using simple parameters such as SPT-N values and seismic response analyses for the pile-supported structure to consider soil-structure interaction effects and soil non-linearity using a modified Penzien model. It is important to find a way to determine the region of surrounding soil whose behavior is identical to that of piles. This paper adopts the thin layer element method to systematically determine the volume of the surrounding soil. The responses of pile-supported structure are similar, whether soil liquefaction and nonlinearity of pile are considered or not. However, the bending moment of pile become large as to soil liquefaction, and small as to nonlinearity of pile. (author)

2000-01-10

13

Relation between frequency of seismic wave and resolution of tomography; Danseiha tomography kaiseki ni okeru shuhasu to bunkaino no kankei  

Energy Technology Data Exchange (ETDEWEB)

With regard to the elastic wave exploration, discussions have been given on the relationship between frequency and resolution in P-wave velocity tomography using the initial travel time. The discussions were carried out by using a new analysis method which incorporates the concept of Fresnel volume into tomography analysis. The following two arrangements were used in the calculation: a cross hole arrangement, in which seismic source and vibration receiving points were arranged so as to surround the three directions of a region extending 250 m in the horizontal direction and 500 m in the vertical direction, and observation is performed between two wells, and a permeation VSP arrangement in which the seismic source is installed on the ground surface and receiving points installed in wells. Restructuring was performed on the velocity structure by using a total of 819 observation travel times. This method has derived results of the restructuring according to frequencies of the seismic ...

1997-05-27

14

Parameters determination of IEC-TDG by directly solving non-linear equation; Chokusetsuho ni yoru IEC-TDG hakei kaiseki  

Energy Technology Data Exchange (ETDEWEB)

An IEC-TDG waveform analysis program that can accurately calculate the waveform parameters in waveforms containing much noise as well as waveforms based on the IEC 1083-2 standard was developed in the impulse voltage and current test field. In the conventional curve fitting method, it is difficult to solve the non-linear equation directly when obtaining waveform parameters from the assigned discrete data. An approximate solution method is low in precision. Therefore, the residual between the standardized data and approximate function was calculated for high-speed Fourier transformation. Unrelated components were eliminated from the calculated frequency spectrum to synthesize waveforms. An L-M method is used for analysis. The solution is first tracked by a maximum diving method. If the convergence is judged to have been largely promoted, the method is switched into a Newton method to continue the calculation. The non-linear equation in a curve fitting part can be solved at a high speed. ...

1997-04-20

15

Numerical analysis of natural convection in a square cavity at high Rayleigh numbers using the GSMAC finite-element method. GSMAC yugen yosoho ni yoru ko Rayleigh su seihokei cavity nai shizen tairyu no hi teijo kaiseki  

Energy Technology Data Exchange (ETDEWEB)

Stable and accurate numerical analytical method even at high Rayleigh numbers is desired, and in addition flexibility and economical efficiency are very important for numerical analysis. Unsteady flows of natural convention in a square cavity are investigated using the GSMAC (generalized and simplified marker and cell) finite-element method at high Rayleigh numbers from 10 {sup 6} to 10 {sup 8}. Validities of the multi-pass algorithm and BTD (balancing tensor diffusivity), which are highly accurate solutions for finite-element method, are investigated by introducing them to the GSMAC finite-element method. As the result, it was found that the multi-pass algorithm has little effect for the GSMAC finite-element method. The steady solutions at the Rayleigh numbers of 10 {sup 5} and 10 {sup 7} agreed well with the bench mark solutions and numerical solutions. Complex transient phenomena at Rayleigh numbers higher than 10 {sup 7} are successfully observed. 12 refs., 11 figs., 4 tabs.

1990-10-25

16

Fault analysis in the very shallow seismic reflection method. 2; Gokusenso hanshaho ni okeru danso kaiseki. 2  

Energy Technology Data Exchange (ETDEWEB)

Fault analysis is required in addition to the ordinary process of structural analysis (CDP stacking) for the examination of discontinuity in the reflection horizon in question. The fault shape restoration principle is that the reflection point of a reflection wave observed at a certain receiving point is on an ellipse with the shock point and receiving point at its focal points and that the sum of the distances between the reflection point and the focal points is equal to the reflection wave propagation time. The DMO velocity is worked out by calculation using the positive travel time and inverse travel time from the common reflection surface. When the reflection surface is inclined by {theta}, the average interval velocity/cos{theta} is called the DMO velocity. When the reflection surface inclination and the average interval velocities are determined separately in this way, the position of the reflection point may be worked out, and this enables the calculation of the amount of ...

1997-05-27

17

Elasto-plastic analysis of settlement of pile foundations. Part 2. ; Prediction of immediate settlement of building. Kui kiso no dansosei chinka kaiseki. 2. ; Kenchikubutsu no sokuji chinka yosoku hoho  

Energy Technology Data Exchange (ETDEWEB)

When the foundations of the building are designed and worked, the prediction calculation of immediate settlement of the building exercised practically is to calculate assuming the earth is a linear elastic body, but the actual stress-strain relationship of the earth is nonlinear and rigidity of the earth becomes lower as strain (or stress) increases. Hence in order to grasp the actual settling behavior of the earth, it is necessary to elucidate the nonlinear relationship between stress and strain. In this article, a prediction method of building settlement is introduced which uses an analytical technique of the multi-layered earth by the linear elasticity theory and takes into consideration strain dependency of rigidity of the earth. Part of the conclusion is as follows which has been obtained by studying the settling behaviors observed in examples of vertical loading tests of the pile foundations and the elasto-plastic settlement analytical method of the pile foundations; the settling ...

1992-12-25

18

Consolidation settlement analysis of pile foundations; Kui kiso no atsumitsu chinka kaiseki  

Energy Technology Data Exchange (ETDEWEB)

Deformation of the ground can be considered as a sum of volume deformation and shear deformation. At circumferential ground of pile axis, simple shear type of shear deformation becomes main factor of settlement. As shear forces with reverse direction are overlapped at parallel face for pile around face of the ground between the piles, the shear deformation is relaxed. At deeper place from top of the pile, volume deformation becomes larger and component of shear deformation approaches to a pure shear type. In case of the land surface loading type consolidation settlement calculation, a method adopting one dimensional consolidation calculating method using only vertical component within stress obtained by elasticity theory even when investigating multi dimensionally is used widely. In Japanese design standards, the method calculating the consolidation settlement by presuming imaginary loading face for land surface is widely adopted. In case of abrasion pile, the imaginary loading face is ...

1997-02-01

19

Analysis of the relationship between the coal properties and their liquefaction characteristics by using the coal data base; Tanshu data base ni yoru tanshitsu to ekika tokusei no kaiseki  

Energy Technology Data Exchange (ETDEWEB)

The relationship between coal properties and liquefaction or gasification characteristics was analyzed by using the analysis and test results and liquefaction characteristics in the coal data base. On liquefaction reaction, the close relation between an oil yield and coal constituent composition or a coal rank is well-known. Various multivariable regression analyses were conducted by using 6 factors as variables such as calorific value, volatile component, O/C and H/C atomic ratios, exinite+vitrinite content and vitrinite reflectance, and liquefaction characteristics as variate. On liquefaction characteristics, the oil yield of dehydrated and deashed coals, asphaltene yield, hydrogen consumption, produced water and gas quantities, and oil+asphaltene yield were predicted. The theoretical gasification efficiency of each specimen was calculated to evaluate the liquefaction reaction obtained. As a result, the oil yield increased with H/C atomic ratio, while the theoretical gasification ...

1996-10-28

20

Analysis of high turbulence combustion in a direct-injection diesel engine with high squish combustion chamber; CFD ni yoru ko squish nenshoshitsunai koranryu diesel nensho no kaiseki  

Energy Technology Data Exchange (ETDEWEB)

Simultaneous reduction of NO{sub x} and particulate emissions in a direct-injection diesel engine has been realized experimentally with a high squish combustion chamber. The purpose of this study is to investigate the effects of high squish combustion chamber on combustion process in detail. Engine CFD code FREC was used for the analysis. The results show the followings. (1) Compared with standard toroidal chamber, high squish chamber generates high turbulence due to strong squish and large expansion flow is caused in the cavity. (2) Rich and high-turbulence combustion, which forms ring area in the cavity under squish lip, continues during the combustion. (3) The high squish combustion chamber keeps fuel long in the cavity and less hid spreads out to the cold clearance volume. (4) For the condition of retarded injection timing, the effect of high squish is mainly observed at initial combustion and high swirl is more effective at diffusion combustion. (author)

1999-08-25

 
 
 
 
21

Theoretical study on composition of gas produced by coal gasification; Sekitan gas ka de seiseisuru gas no sosei ni kansuru kosatsu (HYCOL data no doteki kaiseki)  

Energy Technology Data Exchange (ETDEWEB)

In relation to considerations on composition of gas produced by coal gasification, the HYCOL hydrogen generation process data were analyzed. From the fact that CO concentration (Y) decreases linearly with CO2 concentration (X), element balance of gasification of reacted coal was used to introduce a reaction analysis equation. The equation includes a term of oxygen excess {Delta}(amount of oxygen consumed for combustion of CO and H2 in excess of the theoretical amount), derived by subtracting the stoichiometric oxygen amount used to gasify coal into CO and H2 from the consumed oxygen amount. The {Delta} can be used as a reference to oxygen utilization efficiency. An equation for the {Delta} was introduced. Also introduced was a term for steam decomposition amount derived by subtracting the generated steam from the supplied steam. These terms may be used as a clue to permeate into the gasifying reaction process. This suggestion was discussed by applying the terms to gas composition value ...

1996-10-28

22

Sorption mechanism of solvent vapors to coals; Sekitan eno yobai joki no shuchaku kiko no kaiseki  

Energy Technology Data Exchange (ETDEWEB)

With an objective to clarify the interactions between micropore structure of coal and solvent reagents, a sorption experiment was carried out under solvent saturated vapor pressure. Low-volatile bituminous coal, Pocahontas No. 3 coal, has the aromatic ring structure developed, and makes solvent more difficult to diffuse into coal, hence sorption amount is small. Methanol has permeated since its polarity is high. High-volatile bituminous coal, Illinois No. 6 coal, makes solvent penetrate easily, and the sorption amount was large with both of aromatic and polar solvents. Since brown coal, Beulah Zap coal, contains a large amount of oxygen, and hydrogen bonding is predominant, sorption amount of cyclohexane and benzene having no polarity is small. Methanol diffuses while releasing hydrogen bond due to its polarity, and its sorption amount is large. A double sorption model is available, which expresses the whole sorption amount as a sum of physical sorption amount and amount of permeation ...

1996-10-28

23

Borehole geophysics for delineating the geological structure in the Sakonishi prospect, the Hida area, Japan; Hida chiiki Sako nishi chiku ni okeru boring ko riyo butsuri tansa ni yoru chishitsu kozo kaiseki  

Energy Technology Data Exchange (ETDEWEB)

In order to discuss effectiveness of physical exploration in the Sakonishi prospect in the Hida area, physical exploration was carried out by utilizing bored wells. This area contains the Kamioka mine, one of the major base metal mines in Japan, where electrical exploration has been attempted several times in the past. No effective results have been obtained, however, because specific resistance contrast between mine beds and base rocks is too small, and the topography is too steep making site workability inferior. As part of the investigations on geological structures over wide areas, electrical logging (specific resistance and natural potential) was performed in fiscal 1995 and 1996 by utilizing the boreholes. Induced polarization logging was also conducted on the same boreholes. A traverse line on the ground with a length of 600 m and boreholes were used to execute specific resistance tomography. Clear extraction was possible on a fault structure which is thought related with ...

1997-05-27