As part of the general QC/QA management of the k_0-standardization, three types of 'SMELS' (synthetic multi-element standards) are being developed to check the performance of k_0-NAA when implemented in a laboratory. Phenol-formaldehyde resin is proposed in this paper as the matrix of choice. Based on previous work, this material could be prepared with sufficient purity so as to make interferences with the spiking elements negligible. The matrix was found to be adequately resistant towards high neutron flux irradiation. A selection was made of compounds, soluble in ethyl alcohol, for spiking the prepolymer ethanolic solution with the elements of interest. Finally, some prototypes were prepared and a satisfactory homogeneity of the spiked elements was found for 50 mg sample intake.
Some results of the indoor radon measurements are presented in this paper. Kodac track detectors LR-115 were used for these measurements. Average winter/spring ratio for indoor radon concentration was determined from the results obtained and is presented in this paper. (author).
In 1995 the exercise RESUME-95 (Rapid Environmental Surveying Using Mobile Equipment) took place in Finland. Groups from 8 European countries joined the exercise. The methods used were airborne gamma-ray measurements, car-borne measurements and in situ stationary measurements. The results of the measurements are analyses aiming at disclosing similarities and differences between groups and measuring techniques.
The results of the radon concentration measurements in dwellings in Belgrade were shown in this paper. The measurements were done using long term method with diffusion cups equipped with solid state nuclear track detector LR-115-II or CR-39. (author).
In this paper, some results of the indoor radon concentration measurements are presented. Kodac track detectors LR 115, bare and in a cup were used for these measurements. Average winter/summer ratio was determined for the town of interest. (author). 5 refs, 1 fig., 1 tab.
Short-term radon measurements were used to make a comparison between weekly screening tests and seasonal concentration. The screening measurements were made in an indoor environment over a period of one quarter during early summer and the results are compared with the measured average radon level over that period. In these experiments, the envelope-type and plastic bag monitors were used for screening and long term radon concentration measurements, respectively. The results show that one cannot achieve predicting the seasonal mean radon concentration based on weekly measurements better than 50% under the conditions reported. (author).
Short-term radon measurements were used to make a comparison between weekly screening tests and seasonal concentration. The screening measurements were made in an indoor environment over a period of one quarter during early summer and the results are compared with the measured average radon level over that period. In these experiments, the envelope-type and plastic bag monitors were used for screening and long term radon concentration measurements, respectively. The results show that one cannot achieve predicting the seasonal mean radon concentration based on weekly measurements better than 50% under the conditions reported. (author).
An indoor radioactive survey is being conducted in an Italian district. Preliminary results identified a zone with significant radioactive levels, in which a new specific survey has been planned. In this paper attention is dedicated mainly to radon measurement technique and results.
The preparation by sputtering of artificial metallic superlattices is described, as are the results of x-ray structural determinations. Tunneling and resistivity measurements on these materials are reported.
The LANL 2.5-cell, normal-conducting radio-frequency (NCRF) injector has been fabricated. We present initial results of low-power RF measurements (cavity Q, cavity field map, coupling beta, etc.) of the NCRF injector. The measured cavity Q and relative fields are found to be in good agreement with the design calculations and earlier measurements of Glidcop properties. However, the coupling beta of the ridge-loaded waveguides is found to be significantly higher than the design point. The impact of these low-power measurementresults on the planned high-power RF and electron beam tests will be discussed.
The additional error in measurement of the thickness of Kh18N10T steel for possible changes in composition with an energy of the photons of ionizing radiation of 10-80 keV was evaluated. The desirability of use of a type REIS-I x-ray emitter in measurement of the thickness of steel up to 1 mm is shown. The instrument provides measurement of the thickness of steel in the 0.1-1.0 mm range with a reproducibility of the results with an error not exceeding 0.5-1.0%. The measurement error with corrugations characteristic of bellows does not exceed 5%.
Objective: The aim of this study was to obtain an overview of the methodological quality of studies on the measurement properties of neck pain and disability questionnaires and to describe how well various aspects of the design and statistical analyses of studies on measurement properties are performed. Methods: A systematic review was performed of published studies on the measurement properties of neck pain and disability questionnaires. Two reviewers independently rated the quality of the studies using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. This checklist was developed in an international Delphi consensus study. Results: A total of 47 articles were included on the measurement properties of 8 different questionnaires. The meth...
Power density measurements in the critical facility RA-8 are presented. These measurements were the first systematic use of the reactor. A measurement system was designed, built and proved for this goal. Power profiles are showed and the results are compared with calculated values. (author)
We have performed precision measurements in a magneto-optical trap of the 7P1/2 hyperfine structure of the isotopes 209-210Fr. The ratio of these hyperfine constants to the previously measured 7S1/2 ground state values reveals a significant hyperfine anomaly. This anomaly results from the different radial dependence of the electron density in the two atomic levels. The measurements are sensitive to changes in the radial distribution of the neutron magnetism.
Results of weight measurement of PGV-213 steam generator during filling in, heating-up and power increase are described. Special measurement system based on stress gauges has been developed. Method of derivation of secondary water inventory is described. Comparison of the data for two steam generators prove accuracy of the measurements. (orig.). 1 refs.
The absolute absorption of ozone in the midinfrared has been measured relative to 253.7-nm ultraviolet absorption to an accuracy of 1% using a Bruker Fourier transform spectrometer. These new results agree with previous measurements by diode laser measurements after the latter are corrected for more recent infrared calculations and ultraviolet cross sections. They also agree with a determination based on refractive index measurements in the infrared. 16 refs., 4 figs., 3 tabs.
Additional results using a calorimetric technique for measuring the total hemispherical emittance of pipe surfaces from 400 to 600 K are described. Two different Pyrex pipe enclosures were used, one of 15 cm i.d. and the other of 30 cm i.d. An error analysis showed that the larger diameter Pyrex pipe should have a smaller error, but the difference was negligible for the 4.4-cm test pipe diameter used. Measurements on a short length of a previously-measured pipe agreed with earlier measurements, but only over the temperature range of the measurements. While the technique normally uses a vacuum to minimize nonradiative heat transfer, measurements were done succesfully with an argon atmosphere in a closed system. A nickel-plated pipe, measured first in a vacuum and then in an argon atmosphere, allowed calculation of an ...
The number needed to treat (NNT) is a popular effect measure to present study results in biomedical research. NNTs were originally proposed to describe the absolute effect of a new treatment compared...Full Text Available
BackgroundControversy exists about how to effectively measure patient reported outcomes in IBS clinical trials. Pain numeric rating scales (NRS) are widely used in...Full Text Available
Concentration of an amine solution for removal of hydrogen sulfides and carbon dioxide from natural gas, is tested by carbon dioxide absorption measurement in an apparatus allowing complete reaction to give reliable results.
The standard deviation of measurementresults of a given element in XRF spectrometry depends on three factors: concentration and concentration region, atomic number and matrix. The effects of these factors were investigated by an XRF instrument type ARL 72.000 for aluminium metal, bauxite-red mud and aluminium using computerized data processing. A comparison of linear and nonlinear relation between concentration and the result of XRF analysis was made for the determination of standard deviation. (R.P.).
In in-service inspection of steam-generator tubes, the need for reproducibility of the measurementresults and for comparison of these results over two successive inspections has led EDF to specify the main characteristics of the eddy-current probes and to design equipment to measure them. This equipment is presented here and the electrical and magnetic results are correlated with those obtained by testing tubes with reference defects.
In in-service inspection of steam-generator tubes, the need for reproducibility of the measurementresults and for comparison of these results over two successive inspections has led EDF to specify the main characteristics of the Eddy-Current probes and to design equipment to measure them. This equipment is presented here and the electrical and magnetic results are correlated with those obtained by testing tubes with reference defects. 5 refs.
A Monte Carlo method called transient curve fitting method was developed to calculate a eigenvalues by first simulating the existing neutrons and precursors in the system, then calculating the Eigen-distribution of neutron flux and calculating the a eigenvalues using the transient results based on the Eigen-distribution by the code TMCC. The results of this method are tested by calculating Godiva Benchmark problems and they agree well with the benchmark results. Then the reasonable results of Subcritical Facility in Tsinghua University are given by TMCC, and the results are compared with the experimental resultsmeasured by Rossi-a method. Even in the deep subcritical cases, the method can give results consistent with experimental results. (authors)
Impedance Noise Identification is an in-situ method of measuring battery impedance as a function of frequency using a random small signal noise excitation source. Through a series of auto- and cross-correlations and Fast Fourier Transforms, the battery complex impedance as a function of frequency can be determined. The results are similar to those measured under a lab-scale electrochemical impedance spectroscopy measurement. The lab-scale measurements have been shown to correlate well with resistance and power data that are typically used to ascertain the remaining life of a battery. To this end, the Impedance Noise Identification system is designed to acquire the same type of data as an on-board tool. A prototype system is now under development, and results are being compared to standardized measurement techniques such as electrochemical ...
A calorimetric vacuum emissometer (CVE) capable of measuring total hemispherical emittance of surfaces at elevated temperatures was designed, built, and tested. Several materials with a wide range of emittances were measured in the CVE between 773 to 923 K. These results were compared to values calculated from spectral emittance curves measured in a room temperature Hohlraum reflectometer and in an open-air elevated temperature emissometer. The results differed by as much as 0.2 for some materials but were in closer agreement for the more highly-emitting, diffuse-reflecting samples. The differences were attributed to temperature, atmospheric, and directional effects, and errors in the Hohlraum and emissometer measurements ({+-} 5 percent). The probable error of the CVE measurements was typically less than 1 percent.
This paper presents some situations, in which measurements of electromagnetic fields generated by transmission lines and substations should be performed. The range of measurements may differ, but maximum values of electric and magnetic fields and flux density must be identified in all situations. The area with electric field exceeding 1 kV/m should be identified as well. The author also presents basic requirements to be met by the measurement technique. These requirements are specified according to the national standard. Special attention should be paid to the identification of the spatial distribution of electric field and flux density generated in the vicinity of high voltage transmission lines. To verify the measurementresults, it is necessary to calculate the distribution of both aforesaid field components. For environmental protection purposes, it is also proposed that the ...
14C-dated Holocene coastal uplift, conventional and satellite geodetic measurements, and coseismic and aseismic fault slip reveal the pattern of distributed deformation at Taiwan resulting...Full Text Available
... 1 I3a TYPE OF REPORT 1 3b TIME COVERED ... Measured by this standard the system provides good results; it ... did not fully meet all the standards or ...
A force measurement technique has been developed for large-scale aerodynamic models with a short test time. The technique is based on direct acceleration measurements, with miniature accelerometers mounted on a test model suspended by wires. Measuring acceleration at two different locations, the technique can eliminate oscillations from natural vibration of the model. The technique was used for drag force measurements on a 3 m long supersonic combustor model in the HIEST free-piston driven shock tunnel. A time resolution of 350 #mu#s is guaranteed during measurements, whose resolution is enough for ms order test time in HIEST. To evaluate measurement reliability and accuracy, measured values were compared with results from a three-dimensional Navier-Stokes numerical simulation. The difference between ...
A pump down model for a vacuum chamber with a reversibly adsorbed phase is presented. The outgassing equation which predicts the variation of coverage at the wall surface of a vacuum chamber with time is derived. Then the measured and the true outgassing rates are defined. The theoretical measured outgassing rate shows only a very weak dependence for pumping speed. This prediction is opposite to the experimental result that the measured outgassing rate depends significantly on pumping speed. It is discussed that the experimental measured outgassing rate must be described as the product of the effective pumping speed and the measured pressure in the pumped chamber, in which the measured pressure is equivalent to the equilibrium pressure of the wall surface described by the equilibrium adsorption isotherm as a function of the shifted surface ...
Radon concentration measurement in the ground can be used for the prospecting for uranium and earthquake prediction. Some results of radon concentration measurement in the soil are presented here. The moisture condensation at the detector surface can affect on the detection efficiency. Due to this problem we tested a few filter papers on water permeability. The ratio of track densities on solid state nuclear track detector (SSNTD) in the open and the closed diffusion chamber is also determined. (author)
Measurementresults are interpreted as (sets of) values attributed to measurands, i.e., quantities (intended to be measured), i.e., properties (having a magnitude that can be expressed as a number and a reference). This relatively simple conceptual structure hides some important issues for measurement science, that the lecture will tentatively explore with a systematic reference to the International vocabulary of metrology - Basic and general concepts and associated terms (VIM) and its possible future developments.
Patient monitoring during mechanotherapy based on electrocutaneous impedance measurement is discussed. Methods implemented by the Alpharhythmica computer-assisted system are described. Mechanotherapy modifies electrocutaneous impedance as compared to other parameters: heart rate, arterial pressure, and body temperature. Real time criteria of mechanotherapy efficacy based on electrocutaneous impedance measurement are suggested. Results of electrocutaneous impedance monitoring are presented.
The importance of neutron measurements both as a succinct measure of the progress to fusion ignition using the magnetic confinement route and also as a diagnostic of plasma conditions is discussed. The various neutron diagnostic systems that have been or are being constructed by AERE Harwell for JET are described. The properties to be measured by such diagnostics are clearly identified and some results obtained with the installed diagnostics during d-d plasmas are presented.
A growth model of pitting corrosion of carbon steel in cooling water systems was developed on microscopic observations of pits and electrochemical studies. Results of pitting corrosion measurements in laboratory and field conditions with the model, using a newly developed electrochemical device, are discussed. For an actual heat exchanger up to a year operation, the values of pitting depth estimated were in good agreement with the measured values.
We have measured, by {sup 1}H and {sup 13}C nuclear magnetic resonance (NMR), the percent deuteration, the tacticity and the purity of several polymers and one solvent used in the preparation of microcellular foams. The percent deuteration was measured for polystyrene, polyacrylonitrile and polyethylene. The tacticities of polystyrene and polyacrylonitrile were determined. The purity and degradation products of polyacrylonitrile and maleic anhydride were examined. This report documents the experimental procedures and results of these measurements.
The title refers to the area of research which studies infinite groups using measure-theoretic tools, and studies the restrictions that group structure imposes on ergodic theory of their actions. The paper is a survey of recent developments focused on the notion of Measure Equivalence between groups, and Orbit Equivalence between group actions. We discuss known invariants and classification results (rigidity) in both areas.
Positronium is an ideal system for the research of the bound state QED. New precise measurement of orthopositronium decay rate has been performed with an accuracy of 150 ppm, and the result combined with the last three is 7.0401 +- 0.0007 mu s^-1. It is the first result to validate the 2nd order correction. The Hyper Fine Splitting of positronium is sensitive to the higher order corrections of the QED prediction and also to the new physics beyond Standard Model via the quantum oscillation into virtual photon. The discrepancy of 3.5 sigma is found recently between the measured values and the QED prediction (O(alpha^3)). It might be due to the contribution of the new physics or the systematic problems in the previous measurements: (non-thermalized Ps and non-uniformity of the magnetic field). We propose new methods to measure HFS precisely without the these ...
We describe a fully automated bead puller system which uses stepping motors to position the bead, and an HP-8510 network analyzer to measure the resulting frequency shifts, both devices being under computer control. Longitudinal motion of the bead is used for measurement of cavity shunt impedance. In addition, azimuthal scans at fixed longitudinal position aid in determining the multipole character of higher-order modes. High sensitivity/accuracy is made possible by measuring phase shifts at the unperturbed resonant frequencies (rather than frequency shifts themselves), thereby permitting averaging factors of > 500 with only modest increases in data acquisition time. Sample measurements will be presented. A comprehensive analysis of the experimental results is presented in an accompanying paper.
The method and results are presented of measurements of the coefficients of "2"2"2Rn emanation from samples of fly- ashes and slag and other commonly used building materials. A chamber was used for electrostatic collection of "2"2"2Rn decay products. The coefficients of emanation ranged from 0.2% (fly- ashes) to 21.3% (phosphogipsum from phosphorit). (author).
Image registrations that are based on similarity measures simply adjust the parameters of an appropriate spatial transformation model until the similarity measure reaches an optimum. The numerous similarity measures that have been proposed in the past are differently sensitive to imaging modality, image content and differences in the image content, selection of the floating and target image, partial image overlap, etc. In this paper, we evaluate and compare 12 similarity measures for the rigid registration. To study the impact of different imaging modalities on the behavior of similarity measures, we have used 16 CT/MR and 6 PET/MR image pairs with known 'gold standard' registrations. The results for the PET/MR registration and for the registration of CT to both rectified and unrectified MR images indicate that mutual information, normalized ...
The satellite-borne experiment PAMELA has been used to make a new measurement of the cosmic-ray antiproton flux and the antiproton-to-proton flux ratio which extends previously published measurements down to 60 MeV and up to 180 GeV in kinetic energy. During 850 days of data acquisition approximately 1500 antiprotons were observed. The measurements are consistent with purely secondary production of antiprotons in the galaxy. More precise secondary production models are required for a complete interpretation of the results.
Tank calibration experiments have been carried out using a mock-up input accountancy tank with the object of developing a high accuracy solution volume measurement technique for Rokkasho Reprocessing Plant (RRP). The experimental parameters such as temperature, solution density, off gas pressure and so on have been fluctuated in the calibration experiments in order to evaluate the influence on the solution volume measurement. As a result, it was confirmed that the solution volume measurement error of the mock-up tank was within #+-#0.04% (at full volume) using careful data correction technique for measured data. For the high accuracy volume measurement at RRP, it is important to correct data properly taking account of the actual conditions such as uncontrollable ambient temperature that are different from the experiment. (author)
An apparatus is described for measuring the total hemispherical emittance of pipes of a length suitable for use in a prototype solar collector. The calorimetric method used requires measurements of the temperatures of the surface of the test pipe and of a concentric outer cylinder and measurement of the electrical power used to heat the test pipe. Measurements were made of the total hemispherical emittance of black chrome, nickel, and bare steel pipes as a function of temperature. The emittance of the black chrome surfaces increased significantly from an extrapolated value of about 0.1 at 25 deg C to values on the order of 0.3-0.4 at 300 deg C. The extrapolated values for black chrome agreed with measurements made using other techniques at room temperature. The results for the nickel-plated pipe agreed with total emittance calculated from spectral reflectance ...
Pionier-I is a vertical axis wind turbine (VAWT) of the Darrieus-type with a diameter of 15 m. In the month of September 1983 performance and efficiency were measured. Measurements were done with constant rotational speed and with constant tip speed ratio. For the calculation of the possible (theoretical) output of electric power an anemometer was present. Measurementresults are conditioned to one digital signal and processed by a microcomputer (Apple II). It becomes evident that the yearly energy output of the Pionier-I is quite well comparable with that of a horizontal axis turbine with the same diameter.
Measurements were made of the cross section for /sup 242/Am/sup m/ fission induced by neutrons in the energy range 0.04< or =E/sub n/< or =4.52 MeV as well as by neutrons with E/sub n/roughly-equal14.8 MeV. An electrostatic generator and a low-voltage accelerating tube were used to generate the quasimonochromatic neutrons. Measurements in the low-energy region were made by using the time-of-flight technique in neutrons from a nuclear explosion. Results of the measurements are compared with previously published data.
Tests have recently been performed at Fermilab in order to measure the energy losses due to eddy currents and iron and superconductor magnetization. These measurements were performed on six 1.5m long model magnets and eight 15m long full scale collider dipole magnets. AC losses were measured as a function of ramp rate using sawtooth ramps from 500, to 5000 Amps for both types of magnets, while bipolar studies were additionally performed on some of the short magnets. The measured magnet voltage and current for a complete cycle are digitally integrated to yield the energy loss per cycle. Measurement reproducibility is typically 5%, with good agreement between long magnet measurements and extrapolations from short magnet measurementresults. Magnetization loss measurements among similar magnet types ...
A method of the correction for sample self attenuation used in segmented gamma scanner (SGS) is described. The method of calibration for assaying the uranium and plutonium contents of each category of heterogeneous process residues and wastes in nuclear facilities is studied. The effect of variable measurement parameter on measurementresults is also studied. The measurementresults of SGS assay is compared with that of the destructive assay (DA), which is aimed at evaluating SGS method for assaying uranium and plutonium content in process residues and wastes. The deviation of two assay results is 3.6%. The SGS assay results and DA assay results both are coincided well in error limits. Four category of heterogeneous process residues and wastes in nuclear facilities have assayed successfully in physical inventory. The ...
The masses of the proton-rich nuclides {sup 85,86,87}Mo and {sup 87}Tc have been measured with the Penning trap mass spectrometer SHIPTRAP at GSI. The measured mass excesses of these nuclei deviate from the values of the Atomic Mass Evaluation 2003 by up to 1.6 MeV, indicating a systematic shift of the mass surface in this region compared to previous measurements. A local mass extrapolation based on the new results has been made for the mass range A=80-95. Measured and extrapolated mass values and the derived separation energies have been compared to theoretical mass models. Taking into account the new mass excess values, rp-process network calculations have been performed. Preliminary results show changes in the final abundances for A=86-92 by up to a factor of 30. Results of measurements and calculations are presented, ...
The masses of the proton-rich nuclides "8"5","8"6","8"7Mo and "8"7Tc have been measured with the Penning trap mass spectrometer SHIPTRAP at GSI. The measured mass excesses of these nuclei deviate from the values of the Atomic Mass Evaluation 2003 by up to 1.6 MeV, indicating a systematic shift of the mass surface in this region compared to previous measurements. A local mass extrapolation based on the new results has been made for the mass range A=80-95. Measured and extrapolated mass values and the derived separation energies have been compared to theoretical mass models. Taking into account the new mass excess values, rp-process network calculations have been performed. Preliminary results show changes in the final abundances for A=86-92 by up to a factor of 30. Results of measurements and calculations are presented, ...
A case-control study on lung cancer and radon exposure in dwellings has been carried out in Lazio, a high indoor radon region of Central Italy. A total of about 400 cases and 400 controls were recruited and radon concentration was measured in a total of about 1850 dwellings. In each dwelling, radon concentration measurement devices were placed in both the main bedroom and living room for two consecutive six-month periods. Each radon device, enclosed in a sealed polyethylene bag, contains two LR 115 detectors, each being covered by a thin absorber to reduce the alpha-energy within the detector sensitive range. A quality assurance program, described in this paper, was applied in order to reduce radon concentration measurement uncertainty, which have a significant impact on the results of an epidemiological study. The reported internal quality control and intercomparison results are ...
Neutron energy spectra were measured for two OSURR experimental facilities. The method of multiple foil activation was used with the SAND-II neutron spectrum unfolding code to obtain spectral data for the Central Irradiation Facility and Rabbit tube. Limited data was obtained for the thermal column using only gold foils. Calculations were made of the neutron environment in various locations using the MORSE code. A shift towards higher neutron energies was observed comparing results for LEU and HEU cores. A slight loss in total thermal neutron flux was measured for all positions. Calculational results show reasonable agreement with measured data.
Recent work has been carried out on development of isotope wear analysis and optical and eddy current technologies to provide bearing wear measurements and real time monitoring of shaft speed, shaft axial displacement and shaft orbit of the Orbit Transfer Vehicle hydrostatic bearing tester. Results show shaft axial displacement can be optically measured (at the same time as shaft orbital motion and speed) to within 0.3 mils by two fiberoptic deflectometers. Evaluation of eddy current probes showed that, in addition to measuring shaft orbital motion, they can be used to measure shaft speed without having to machine grooves on the shaft surface as is the usual practice for turbomachinery. The interim results of this condition monitoring effort are presented.
A technique for the measurement of the total hemispherical emittance of pipe surfaces is described, and design and operational details are given. The technique is conceptually simple. A long test pipe (e.g., 3.4 m) is mounted concentrically inside a Pyrex glass pipe. The system is evacuated, and the test pipe is heated by means of an electrical resistance heater. Heat transfer from the test pipe to the enclosure is almost solely radiative, allowing an average emittance for the test pipe and the Pyrex pipe and the electrical power input to the heater. By varying the electrical power level, one can measure the test pipe emittance as a function of temperature. By using a simple correction to account for the finite length of the test pipe, one can calculate the results using the simple expression for infinite, concentric cylinders. Results agree with measurements by reflectance ...
The results of radon concentration measurements in the near surface air at San Nicolas Island, California, are presented for five different measurement sessions between May 1978 and July 1980. Emphasis is on the previously unreported results for January and July 1980. For six of eight days during the January session the measured radon concentration was greater than 40 picocuries per cm, corresponding to a continental air mass. Only the first day involved a maritime air mass with radon concentration less than about 6 picocuries per cm. In contrast to all the previous sessions, maritime air dominated the ten day session in July 1980, with radon concentrations generally less than about 5 picocuries per cm.
The benchmark calculations have been performed for MCNP-4B code using the measurement data of Wolsong nuclear power plant 2. In this study, the benchmark calculations have been performed for the criticality, boron worth, reactivity device worth, reactivity coefficient, and flux scan. Cross-section libraries were newly generated from ENDF/B-VI release 3 through NJOY97.114 data processing system and a three-dimensional full core model was developed for MCNP calculation. The simulation results have shown that the criticality is estimated within 4 mkn and the estimated reactivity worth of the control devices are generally consistent with the measurement data. In certain cases, the simulation results have shown large discrepancies against the measurement data, which will be sturdied further in the near future.
The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, ...
The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of monitoring any changes in ...
Pollution abatement measures against impulsive low frequency noises including mine blasting noise require precise measurement of sound waveforms, but no instruments have been designed for that purpose, nor commercially available. This paper describes investigations on such instruments as noise level meters currently available commercially on their instrumental characteristics using indoor experiments and field measurements. The following matters were clarified: An instrument combining a microphone with an amplifier can not determine the response from the measuring system from the respective frequency characteristics alone, and requires a discussion on the overall response from the measuring system. A preferred noise level meter would be an instrument that has the lower limit for the frequency characteristics of the microphone extended to several hertz, and ...
Traditional laboratory diffusion experiments in rock material are time consuming, and quite small samples are generally used. Electrical conductivity measurements, on the other hand, provide a fast means for examining transport properties in rock and allow measurements on larger samples as well. Laboratory measurements using electrical conductivity give results that compare well to those from traditional diffusion experiments. The measurement of the electrical resistivity in the rock surrounding a borehole is a standard method for the detection of water conducting fractures. If these data could be correlated to matrix diffusion properties, in-situ diffusion data from large areas could be obtained. This would be valuable because it would make it possible to obtain data very early in future investigations of potentially suitable sites for a repository. This study compares laboratory ...
The consistency of different instruments and methods for measuring two-dimensional (2D) power spectral density (PSD) distributions are investigated. The instruments are an interferometric microscope, an atomic force microscope (AFM) and the X-ray Reflectivity and Scattering experimental facility, all available at Lawrence Berkeley National Laboratory. The measurements were performed with a gold-coated mirror with a highly polished stainless steel substrate. It was shown that these three techniques provide essentially consistent results. For the stainless steel mirror, an envelope over all measured PSD distributions can be described with an inverse power-law PSD function. It is also shown that the measurements can be corrected for the specific spatial frequency dependent systematic errors of the instruments. The AFM and the X-ray scattering measurements were used ...
The consistency of different instruments and methods for measuring two-dimensional (2D) power spectral density (PSD) distributions are investigated. The instruments are an interferometric microscope, an atomic force microscope (AFM) and the X-ray Reflectivity and Scattering experimental facility, all available at Lawrence Berkeley National Laboratory. The measurements were performed with a gold-coated mirror with a highly polished stainless steel substrate. It was shown that these three techniques provide essentially consistent results. For the stainless steel mirror, an envelope over all measured PSD distributions can be described with an inverse power-law PSD function. It is also shown that the measurements can be corrected for the specific spatial frequency dependent systematic errors of the instruments. The AFM and the X-ray scattering measurements were used ...
A crossed-electron-ion-beam experiment was used to measure the total ionization cross section for Ar"8"+ in the energy range from 50 to 600 eV. The present results are roughly in agreement with the previous measurements of Defrance et al. [Nucl. Instrum. Methods Phys. Res. B 23, 256 (1987)] above 450 eV. However, the present measurements show a significant contribution below the threshold for direct ionization. The present measurements agree with the distorted-wave calculations of Pindzola et al. [Phys. Rev. A 41, 1375 (1990)] when 3% of the incident ion beam is assumed to be in metastable states and excitation autoionization from metastable states is included.
Temperature measurement technique by using Raman scattering was developed for the liquid water at temperature of 20 - 90 degree C and atmospheric pressure. Strong relationship between Raman scattering characteristics and liquid temperature change was observed. Various kinds of measurement techniques, such as Peak Intensity, Peak Wavelength, FWHM (Full Width at Half Maximum), PMCR ( Polymer Monomer Concentration RAte), TSIR (Temperature Sensitive Intensity Ratio), IDIA (Integral Difference Intensity Area) were tested. TSIR has the highest accuracy in mean error or 0.1 deg C and standard deviation of 0.1248 deg C. This report is one of the results in developing process of Raman temperature measurement technique. Next research step is to develop Raman temperature measurement technique at the high temperature and high pressure conditions in single or two phase flows. (author). 13 refs., ...
Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is presented and ...
Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is presented and ...
In order to study nuclear criticality safety related to the development of fast breeder technology, /sup 252/Cf-source-driven neutron noise analysis measurements were performed with a Pu-U nitrate solution in a slab tank of various heights and thickness varying 11.43 cm to 19.05 cm. The results and conclusions of these experiments are (1) a capability to measure the subcriticality of a multiplying system of slab geometry to a k/sub eff/ as low as 0.7 was demonstrated, (2) calculated neutron multiplication factors agreed with those from the experiments within approx.0.02, and (3) the applicability of the method for plutonium solution systems was demonstrated. This paper describes measurements in which the height of the slab was varied for a fixed thickness and the thickness varied for a fixed height, which are the first applications of this measurement method to slab geometry.
This paper first introduces the calculating method of radium specific activity to determine the radon emanation rate of tailing of uranium mine No. 794, the method needs two parameters: radon emanation coefficient and radon diffusion coefficient. According to the measuredresults of parameters and the contrast between radium specific activity of indoor chemical analysis of field sample and field gamma-ray spectra, the authors discuss the variation rules and characteristics of radon emanation coefficient and radon diffusion coefficient, and the best climate and seasons for measuring these parameters in northern China, and finally summarize the characteristics of this method through analyzing measuredresults. (authors)
Finding interesting rule in the sixth strategy step about threshold control on generalized relations in attribute oriented induction, there is possibility to select candidate attribute for further generalization and merging of identical tuples until the number of tuples is no greater than the threshold value, as implemented in basic attribute oriented induction algorithm. At this strategy step there is possibility the number of tuples in final generalization result still greater than threshold value. In order to get the final generalization result which only small number of tuples and can be easy to transfer into simple logical formula, the seventh strategy step about rule transformation is evolved where there will be simplification by unioning or grouping the identical attribute. Our approach to measure interesting rule is opposite with heuristic measurement approach by Fudger and Hamilton where the ...
The results of the development work to improve the horizontal steam generator modelling using the CATHARE code as well as the results of the steady-state and the steam-line break calculations are presented. Also the results of the steady-state calculations are compared to the measurements performed in operating VVER power plants. (9 refs., 6 figs., 2 tabs.).
The results of the development work to improve the horizontal steam generator modelling using the CATHARE code as well as the results of the steady-state and the steam-line break calculations are presented. Also the results of the steady-state calculations are compared to the measurements performed in operating VVER power plants. (9 refs., 6 figs., 2 tabs.).
The progress of digital audio technology enabled the familiar use of the products such as CD and DAT in the acoustic measurement. For example, a signal reproduced with CD player is inputted into a subject of measurement and DAT recorder records its response. However, the sampling cannot be synchronized completely with the input signal although both nominal sample rates are set up equally, because player and recorder work independently. It is the most popular software solution to perform the synchronous addition after converting the recorded signal into the original sampling rate. However, the rate conversion also has the error due to the windowing in the high frequency region of processed signal. This paper proposes a new method for averaging asynchronous sampling data to solve these problems. To evaluate performance, the transfer function of only measuring equipment estimated from asynchronous sampling data was compared ...
Within the framework of the German Federal-State 1000 Roofs Photovoltaic Programme monthly measuring data and verbal comments on the PV system operation (reports on failures and defects) have been collected, stored in a databank and evaluated for the period 1991 to 1997 for a differing number of PV systems. In addition to this came along data of initially 100, then 40 intensively measured systems. The results of the measuring data evaluation as well as the results of further accompanying research projects to the Federal-State 1000 Roofs Photovoltaic Programme (e.g. low energy yield analysis, on-site inspections and measuring of nominal powers) are summarised. Starting from the gained results, conclusions and recommendations are given for the design, installation and operation for future grid-connected PV-systems. Also it is pointed to the ...
Complete text of publication follows. At the Geomagnetic Institute, in the Laboratory for paleomagnetism and archeomagnetism research and at the Geomagnetic Observatory, Grocka (GCK) during the period from November 2004 to February 2008 the researchers carried out experimental magnetic measurements of the total-intensity gradient of the magnetic field vector (changes in the total magnetisation vector) of various biomaterials. Measurements of the gradient total intensity of the magnetic field vector were carried out by GSM-19 magnetometers of high accuracy and recording resolution (accuracy: #DELTA#F=0.1 nT; sampling rate: 1-5 per second). During these experimental biomagnetic measurements samples of water, tissue, blood, cotton, wool, pitch and magnetite-powder were used. In this study, the part of the biomagnetic measurementresults relate to the water, blood and tissue. The ...
The half-life of "1"0"9Cd was measured by following the decay of sources from a radiochemically pure solution with two different measuring systems: an ionisation chamber and a high-purity germanium (HPGe) detector. The measurements were performed over a period of 3.6 years, i.e. about 2.8 half-lives of "1"0"9Cd. The resulting half-life values and detailed uncertainty budgets (k=1) are presented for both systems. The result obtained with the ionisation chamber, 462.36 (33) days, and the one obtained with the HPGe detector, 461.92 (76) days, are mutually consistent. The weighted mean of our measured values, T_1_/_2("1"0"9Cd)=462.29 (30) days, is consistent with the currently recommended values of 461.4 (12) days and 462.0 (3) days. From a set of selected experimental values published after 1970, a 'partially weighted mean' of T_1_/_2("1"0"9Cd)=462.36 (39) days was ...
A measurement of environmental radioactivity in Tokyo was started from 1974. We have been executing fixed time and fixed point observation since 1983 in Tokyo continuously. Measurement item is rain water, airborne dust, activated sludge at sewage treatment plants and external dose rate. Measurement data from 1983 to 1995 is reported in this paper. Moreover, we have been carried out the measurement of radon concentration in air from 1988 to 1991 in different types of residental buildings. The measurementresults of rain water, airborne dust, external dose rate were approximately a background level respectively except for the Chernobyl nuclear power plant accident. Radionuclides used as radiopharmaceuticals were detected in the activated sludge at every sewage treatment plant but its concentration was lower than concentration limit in Japan. From a ...
A method for determining the reactivity of subcritical systems of fissile material, using neutron-noise power spectral density measurements in conjunction with a /sup 252/Cf source, has been tested in experiments with an aqueous solution containing uranium fluoride (4.95 wt% /sup 235/U). The kappasub(eff)-values obtained from the ratio of spectral densities G*/sub 12/G/sub 13//G/sub 11/G/sub 23/ agreed with those from break-frequency noise analysis and with bias-corrected transport theory calculations within the statistical uncertainty of the measurements. Corrections for the effects of spatial modes and source-detector locations appear to be well-understood, since measurements for a variety of source-detector positions resulted in essentially the same kappasub(eff)-values. Modal correction factors were such that ignoring them would result in higher values of kappasub(eff) than ...
The refrigerant two-phase flows in a distributor and a simulated plate heat exchanger with a single passage used in a compression-type refrigerator were visualized by real-time neutron radiography. For a distributor, the liquid fraction in the each tube was measured by some image processing method. On the other hand, for a plate heat exchanger, the two-dimensional distribution of void fraction was measured quantitatively by the umbra method. As a result, it was shown that the dynamic behaviors of refrigerant at the inlet of the section strongly affected on the performance, that is, a distribution performance of a distributor and a liquid distribution in a plate heat exchanger. (author)
Three different techniques for pitting corrosion potential measurement on austenitic stainless steel (Fe18Cr10Ni) were compared: conventional polarization method, a new Avesta electrochemical corrosion measurement cell and a scratch technique. Special attention was paid to the effects of crevice corrosion during pitting corrosion potential measurement and to their elimination. Development of a rapid test technique for reliable pitting corrosion potential determination was aimed at and resulted from comparison of the different techniques.
One of the most important goals of the Italian survey, initiated in 1989, was to promote ad hoc policies to reduce radon exposure of the population. In the survey a statistical representative sample of 5000 dwellings was chosen; two six-month measurements were made of the indoor radon concentration, in combination with one six-month measurement of gamma exposure. The results of the radon concentration measurements are reported here: they refer to 80% of the sample. The annual mean value was 81.5Bq.m{sup -3}, which is higher than that reported for other industrialised countries. (author).
Evaluates a mathematical model that describes subsidence of spoil banks in surface brown coal mines. The model is based on the results of geodetic surveys carried out in 1974-1985. Twelve spoil banks from 4 to 61 m high were considered. Ground subsidence and deformation along 12 measuring lines and 6 measuring networks were measured. Ground subsidence during a period of 18 to 241 months was evaluated using regression analysis. The mathematical model considered effects of spoil bank design (number and thickness of rock layers), rock mechanical and physical properties and service time. 6 refs.
Laser Doppler velocimetry and other photometric techniques are evaluated for measuring the average particle velocity in an ensemble of free-falling particles. The ability to obtain measurements in the presence of a radiant flux as high as 0.6 MW/m/sup 2/ was part of the evaluation. Optically dissimilar particles with diameters ranging from 0.1 mm to 1 mm were used in the study. Experimental results indicate that ensembles of particles do not behave as single isolated particles. The particle motion is dependent on particle volume fraction, and is quite unstable for falls greater than one meter.
Laser Doppler velocimetry and other photometric techniques are evaluated for measuring the average particle velocity in an ensemble of free-falling particles. The ability to obtain measurements in the presence of a radiant flux as high as 0.6 MW/m/sup 2/ was part of the evaluation. Optically dissimilar particles with diameters ranging from 0.1 mm to 1 mm were used in the study. Experimental results indicate that ensembles of particles do not behave as single isolated particles. The particle motion is dependent on particle volume fraction, and is quite unstable for falls greater than one meter.
Reactive sticking coefficients (RSCs) were measured for silane and disilane on polycrystalline silicon for a wide range of temperature and flux (pressure) conditions. The data were obtained from deposition-rate measurements using molecular beam scattering and a very low-pressure cold-wall reactor. The RSCs have nonlinear Arrhenius temperature dependencies and decrease with increasing flux at low (710 /sup 0/C) temperatures. Several simple models are proposed to explain these observations. The results are compared with previous studies of the SiH/sub 4//Si(s) reaction and low-pressure chemical vapor deposition-rate measurements.
In Sweden there is a demand for a method of measuring radon in dwellings with high accuracy and at a low cost. A method of determining radon concentration (Bq.m/sup -3/) in dwellings has been developed at the Swedish National Testing Institute. A plastic canister containing activated charcoal has been tested in a radon chamber (volume 20 m/sup 3/) to determine the effects of relative humidity, temperature and exposure time. The activated charcoal in the canister adsorbs radon from the air surrounding the canister. The radon concentration is determined by counting the gamma rays from the decay of radon and daughters. The theory and preliminary results from calibrations and field measurements are reported.
Special beam extraction channel is used at INR linac for isotope production. It starts from 160 MeV measuring and matching area of accelerator. This choice of beam extraction enables to direct to the target of isotope complex a proton beam of wide energy range up to 160 MeV. It is important for production of different types of nuclides. The measuringresults of proton beam behavior in this region are presented. Required beam forming in 160 MeV measuring and matching area of accelerator and in beam extraction channel is discussed.
During this reporting period the work supported by the US Department of Energy Grant No. DE-FG02-87ER40326.A005 has resulted in two publications and two papers presented at professional meetings. The neutron scattering measurement for this budget period has been completed along with scattering measurements for carbon {sup 88}Sr, {sup 40}Ar, {sup 90}Zr, {sup 208}Pb, {sup 40}Ca and {sup 28}Si. The carbon scattering yield serves to define the detector efficiencies. The silicon sample was available and is of importance in both nuclear physics and reactor physics.
Abstract This article summarizes the results of a Nutrient Biomarker Study in the Women's Health Initiative, and its application to studies of the association between energy and protein consumption and the risk of major cancers and cardiovascular diseases. The presentation emphasizes measurement error modeling and related data analysis methods, since addressing measurement issues appears to be central to these topics and to progress in nutritional epidemiology more generally. The manner in which body mass index is modeled in disease association analysis is particularly challenging, since it could serve as a mediator or as a confounder of the association, and at the same time contributes valuably to energy and protein consumption assessment. A hazard ratio parameter estimation procedure tha...
Cement-based composites are widely used in applications which demand long-term service life. One important example is in immobilization matrices for low-level radioactive and other hazardous wastes, which demands long-term retention and durability. The authors describe conductivity measurements of grouts flooded with water and in contact with a sink that consists of pure water. The conductivity measurements were designed and carried out in parallel with present quality verification methods and standard leach tests of the nuclear waste management industry. For the first time, the authors show that the method of replacing intrusive chemical analysis with conductivity measurements of the leaching samples yields equivalent results.
Magnesium cast parts as well as indirectly and hydrostatically extruded profiles were used in order to investigate the influence of different microstructures on the damping behaviour of magnesium AZ-alloys. Especially, hydrostatic extrusion leads to a significant grain refinement in the extruded profile compared to indirect extrusion. Strain dependent damping measurements were carried out at room temperature using alloys AZ31, AZ61 and AZ80. Damping was determined as the logarithmic decrement of free bending beam vibrations. The results of these measurements after indirect and hydrostatic extrusion are shown and discussed. (orig.)
After presenting the advantages of applying neutron moisture gages to the continuous measurement of blast-furnace coke moisture and explaining the factors influencing the measurement accuracy, the necessity of calibrating these devices under flow conditions and the encountered difficulties are discussed. Using statistical methods it has been observed that the main source of calibration errors is the sampling phase. Based on results of mathematical processing, a new calibration method with higher performance - compared with the earlier ones - is proposed. This method allows to achieve high accuracy in a relatively short time. (author).
Exact anatomic knowledge about the location of the gonads and the application of corresponding measures of radiation protection are the preconditions for an efficient reduction of the danger of a possible genetic damage as a result of radiation exposition during X-ray examination of the hip joint of newborns. (VJ).
The activity of mice in their home cage is influenced greatly by the cycle of light and dark. In addition, home-cage activity shows remarkable time-dependent changes that result in a prominent temporal...Full Text Available
1. The relation of V̇O2 and speed was measured on seven athletes running on a cinder track and an all-weather track. The results were compared...Full Text Available
The radioactive decay of "2"0"3Bi is studied. A level scheme is proposed for "2"0"3Pb on the basis of #gamma#-ray and electron spectra and #gamma#-#gamma# coincidence measurements. The experimental data are compared with theoretical results obtained in a three quasiparticle approximation. (Auth.).
The measuredresult of charged multiplicity in cosmic-ray proton induced nuclear reaction from Chinese satellite emulsion is reported. The correlation of shower and heavy particles is discussed and compared with p-emulsion interactions.
The problems of the thermal stress in concrete structures are roughly divided into the initial stress due to setting heat and the stress due to external temperature after hardening. The initial stress exists in every concrete structure, and it is usually neglected in beams and columns, but it must be taken into account in case of the foundation mat structures in nuclear power stations, for example. In this paper, (1) the results of measurement of temperature, strain and stress in each lift at the time of and after placing concrete in the foundation mat of a nuclear power station and the comparison of them with the results of analysis, (2) the results of measurement of the temperature and stress in a foundation mat, which was carried out to rationalize the design method for the raft type foundation mats in thermal power stations, and (3) the results of ...
The report gives results of the measurement of dissolution rates of reagent CaCO3 and commercial limestones (9 types/19 grinds) at constant pH and solution composition by batch titration with HC1. Conditions were selected to simulate flue gas desulfurizat...
Presentation of electromagnetic sources constituted by various radio transmitters contributing to different radio communication services in the environment. Results of a measures campaign to assess the electromagnetic field in the close neighbourhood of various stations. Analysis by frequency domains. (author)
Previous ultrasound elasticity imaging experiments supported a generally accepted concept that the hardness of deep venous thrombi increases with thrombus aging. Results also showed that this...Full Text Available
Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final...Full Text Available
K_#beta#/ K_#alpha# x-ray intensity ratio of chromium were measured in different chromium compounds. The results show the variation of the intensity ratio as a function of the chemical environment around the metal ion. (author)
With an objective to discuss applicability of resistivity imaging using electromagnetic migration to detection of underground cavity, an applicability test was carried out on calculation of a numerical model and measurement data. By using the numerical model, a calculation was performed on a hypothetical case that a cubic cavity with sides each at 40 m exists in a homogenous medium of 200 ohm-m, with the cavity top located 20 m below the ground surface. As a result, it was possible to structure in a very short calculation time an image of the cavity which cannot be identified by one-dimensional inverse analysis. In the case of this cavity, a center of the image was structured on its lower face. It was shown that a location to indicate the image must be changed according to difference in the measurement locations. In a test on data measured in an underground cavity in the city of Utsunomiya, Tochigi ...
Recent results using B_s -> J/Psi phi decays for measuring the CP violating phase, phi_s, and the decay width difference for the two mass eigenstates, Delta Gamma_s, are presented from the CDF and D0 experiments at the Fermilab Tevatron collider.
IntroductionThe goal of this study was to identify serum markers that are modulated by treatment with golimumab with or without methotrexate (MTX) and are associated with clinical...Full Text Available
After that power fluctuations had occurred at Borssele nuclear power station it was decided to install a power system stabilizer. This stabilizer shall reduce the unwanted power fluctuations. The preliminary research and the results of measurements carried out during commissioning are described. (J.C.R.)
Weakly penetrating radiation monitoring and investigating with area monitors and individual dosimeters were carried out at Daya Bay nuclear power plant during its refueling outages. This paper introduces monitoring methods, measuringresults, data analysis and assessment, presents some suggestions for monitoring plan and protection measures in the future as well. (authors)
Presented are results of a test of a method for measuring neutron fluences using detectors with fissionable nuclides. The investigations show the soundness of of using neutron-activation detectors of the type Am for mesurements in nuclear installations for values of thermal-neutron fluence of from 10/sup 13/ to 10/sup 20/ neutrons/cm/sup 2/ with exposure for up to several months. The proposed method can be used for prolonged measurements in strong fields of both thermal and fast neutrons.
Wind-tunnel measurements were taken of the time-average aerodynamic forces and moments on a notional model of a semi-submersible offshore drilling rig at two heights and at various attitudes to the wind. Attempts were made to analyze the separate effects ...
'Within 15 years the energy consumption bottleneck has shifted from the supply side to emissions, i.e. to the waste side.' Reflecting this statement one may realize the importance of lending more weight to energy conservation but may also be induced to critically analyze the corresponding measures. First results of such reflections are given with regard to the payback periods of air pollution abatement measures relative to the additional emissions they cause. (orig.).
Surface deposition probe techniques have been shown to be an effective means of determining the characteristics of the plasma edge region of magnetic confinement devices. Experimental results on ISX-B and EBT-S have led to a consistent picture of the edge plasma and the dominant impurity introduction mechanisms. This picture is supported by numerous other measurements and emphasizes the importance of concentrating several techniques on the complex problems of plasma fusion.
Surface photometry of bulges and elliptical galaxies is reviewed. The properties of cores and nuclei as revealed by improvements in seeing and the use of CCDs are examined, and newly discovered structural details such as dust, shells, and dynamical subsystems which show the importance of accretion events in galactic evolution are addressed. Improved constraints on galaxy formation resulting from better measurements of parameter scaling laws are discussed, and accurate measurements of departures from elliptical isophotes and of color gradients obtained with CCDs are considered.
Given a random variable $F$ regular enough in the sense of the Malliavin calculus, we are able to measure the distance between its law and almost any continuous probability law on the real line. The bounds are given in terms of the Malliavin derivative of $F$. Our approach is based on the theory of It\\^o diffusions and the stochastic calculus of variations. Several examples are considered in order to illustrate our general results.
Simulation of the skim-off method for radon measurement by activated charcoal has been carried out by the finite elements method. The variation of radon concentration with peak appearance has been simulated. The thickness of the layer of charcoal removed after exposure and the time of peak appearance have been varied. For the charcoal and canister geometry used, the best results were found when the thickness of the layer removed was 1.72 mm.
Infiltration of radon from the ground is usually the primary source of indoor radon pollution. A uniform method for radon risk classification of foundation soils based on soil-gas radon concentration measurements and on the determination of soil porosity, permeability and structure was proposed in 1990. Results of assessment of some areas in Czechoslovakia, containing more than 5000 radon concentration measurements, demonstrate the utility of the technique and confirm the link between geology and radon potential of the soil. (author)
We have measured the oxygen positions in LaNiO{sub 3} films to elucidate the coupling between epitaxial strain and oxygen octahedral rotations. The oxygen positions are determined by comparing the measured and calculated intensities of half-order Bragg peaks, arising from the octahedral rotations. Combining ab initio density-functional calculations with these experimental results, we show how strain systematically modifies both bond angles and lengths in this functional perovskite oxide.
Stereoscopic Particle Image Velocimetry (PIV) measurements are made in horizontal planes in a simplified scale model of a spray dryer using water as fluid. The sample rate was sufficient to resolve phenomena at lower frequencies. Data reveal asymmetric velocity fields in both mean fields and dynamics. Data were analysed using Proper Orthogonal Decomposition (POD). An important periodic event is an elongation of the jet core cross section that results in a downstream displacement of the jet towards the chamber wall.
The results of measuring elastic ..pi../sup -/ d backward scattering, which emphasize the structure in the energy dependence of this cross section observed by us at slightly lower energies, are presented. Its possible theoretical interpretation is discussed.
Frequency response measurements are used to determine the carrier lifetime of 1.3-..mu..m InGaAsP buried heterostructure lasers between 1 mA and threshold. The data confirm previous results on the radiative and Auger recombination coefficients and reveal the presence of a nonradiative current which dominates at low currents and contributes 4 mA at threshold.
The nuclear interaction probability of light charged particles in BaF[sub 2] crystals has been studied as a function of the incident particle energy. Light charged particles were identified in charge and mass by measuring their magnetic rigidity and their time-of-flight. The percentage of particles undergoing nuclear interactions has been measured for particles of charge from Z=1 to Z=6 and the experimental data are compared with the results of a model calculation. (orig.)
We report the corrected intercomparison of the World Radiometer Reference (WRR) irradiance scale and the Electrotechnical Laboratory (ETL) spectral irradiance scale. In addition, we confirm the intercomparison precision using the test facility where the irradiance of ETL 500 W standard lamp can be measured directly with the cavity radiometer. The results showed that the irradiance based on the WRR scale was 0.5-0.7% lower than the one based on the ETL scale
An analysis of the diagnosis of loading and service dependability of a rail-mounted excavator used in surface lignite mining is described. Wheel power vibrations in electric motor bearings and electric motor input bearings to the gearbox were measured in situ, in horizontal, vertical, and axial directions. The data were analyzed using a mathematical relationship. The results are presented in a loading diagram that shows the deterioration and the acceptable lower bound of machine conditions over time. Work is continuing. 5 refs., 1 fig.
A design concept is presented for an in-bundle gamma densitometer system for measurement of subchannel average fluid density and void fraction in rod or tube bundles. This report describes (1) the application of the design concept to the Thermal-Hydraulic Test Facility (THTF) electrically heated rod bundle; and (2) results from tests conducted in the THTF.
The Monte Carlo transport codes LAHET and MCNP were used to calculate energy fluence spectra at three neutron therapy facilities. The results compare very favourably with measured data. Kerma spectra and the ratio of ICRU muscle tissue kerma to A-150 kerma, along the carbon to oxygen kerma ratio, were determined. Absorbed dose rate calculations are in reasonable agreement with measured values. Use of these codes to study modifications to existing therapy beams is briefly discussed. (author).
The purpose of the work described in this dissertation is to increase the understanding of injection-pultrusion process. Three major substudies related to injection-pultrusion have been completed: measurement of the compressibility of fiber reinforcements, measurement of in-plane and transverse resin flow through fiber reinforcements, and development of a resin flow model. This dissertation also presents results of an experimental and analytical investigation of in-plane and transverse resin flow through fiber reinforcements.
An American Society of Mechanical Engineers task group on stainless steel weld materials was organized to determine the need for ferrite measurements of production welds required by the US Nuclear Regulatory Commission Regulatory Guide 1.31 (Rev. 1). The task group studied paired ferrite measurements (i.e., calculated and measured ferrite numbers (FNs) for the material qualifications versus measured ferrite numbers for corresponding production welds (PWs)). Our purpose was to compare delta-ferrite content as measured in the filler metal weld qualification pad with that in the resultant PW. Welds made predominantly by three common processes (submerged arc, shielded metal arc, and gas tungsten arc) were included in the study. Weld metals investigated included types 308, 308L, 316, and 316L stainless steel. An initial evaluation of the paired ferrite ...
Aluminum hydroxide coating thicknesses were measured on fuel elements stored in aluminum canisters in K West Basin using specially developed eddy current probes . The results were used to estimate coating inventories for MCO fuel,loading. Brushing tests successfully demonstrated the ability to remove the coating if deemed necessary prior to MCO loading.
The Netherlands Energy Research Foundation investigated the acidification of fog and dew. Both have little effect on the total acid deposition, but they contribute strongly to the hazardous effects on plants. In particular the effects of hydrogen peroxide and sulfite in fog and dew on plants have been investigated. Special attention is paid to the development of the measurement and sampling equipment. Results of the measurements are presented. 9 figs., 4 refs., 1 tab.
This work deals with a time-resolved optical study of the avalanche and streamer formation phases leading to breakdown in atmospheric nitrogen. The authors present the results obtained for nitrogen, from experiments and two-dimensional model simulations. This model is used to obtain a better insight in the relevant mechanisms and processes by a comparison of measurements and simulation data. The trends of externally measured quantities correspond with those predicted by the model.
A method for calculation of absorbed dose distributions in three dimensions for 1-20 MeV photons is presented. The method uses convolution/superposition of photon fluence distributions with energy scattering kernels. Results for Co-60 and X-ray beams in homogeneous and inhomogeneous media are compared with measurements. Good agreement is found between calculations and measurements. 8 refs.; 3 figs.
Progress in four research areas on this project are summarized under the following topics: (1) Geminate charge pair recombination in hexane; (2) Fast current measurementsresulting from excitation of charge transfer (CT) states; (3) Measurement of the dipole moment of excited states by DC conductivity; and (4) Charge separation at macroscopic interfaces between electron donor and acceptor solids. In a final section, personnel who have contributed to the project during the past budget period are described.
The paper presents results of measurements of the natural radioactivity of tap water where samples were taken in front of, and behind the ceramic filter commonly used in houses for the purification of tap water. Altogether, 289 samples were taken, processed and measured during 1985-1986 in Kuwait. Results reveal the fact that ceramic filters reduce substantially the natural radioactivity in water (the 'gross' alpha activity reduced by the factor 2.18 #+-# 18%; the 'gross' beta by 1.53 #+-# 1.6%. (author).
Sulfuric acid hydrogen peroxide mixtures (SPM) are commonly used in the semiconductor industry to remove organic contaminants from wafer surfaces. This viscous solution is very difficult to rinse off water surfaces. Various rinsing conditions were tested and the resulting residual acid left on the water surface was measured. Particle growth resulting from incomplete rinse is correlated with the amount of sulfur on the wafer surface measured by Time of Flight Secondary Ion Mass Spectroscopy (TOF-SIMS). The amount of sulfur on the wafer structure after the rinse step is strongly affected by the wafer film type and contact angle prior to the SPM clean.
The intrinsic decay rate of orthopositronium formed in SiO/sub 2/ powder is measured using the direct 2 gamma correction method such that the time dependence of the pick-off annihilation rate is precisely determined. The decay rate of orthopositronium is found to be 7.0396+or-0.0012(stat.)+or-0.0011(sys.)/ mu s/sup -1/, which is consistent with our previous measurements with about twice the accuracy. Results agree well with the O( alpha /sup 2/) QED prediction, and also with a result reported very recently using nanoporous film.
The results of weekly radon concentration measurements in an office environment using a novel envelope-type radon monitor for short-term exposure periods are presented. The commercially available LR-115 damage track detectors are used and the chemically etched sheets are spark counted. The measurements were made over a period of one year. The indoor radon concentration varies from {approx} 20 Bq.m{sup -3} to {approx} 300 Bq.m{sup -3} with the average of 130, 81 and 73 Bq.m{sup -3} for three different rooms resulting in the annual dose of 4.5, 2.8 and 2.5 mSv, respectively. (author)
The K-shell X-ray intensity ratios for W, Au, Tl, Pb, Bi, Th and U were measured at a photon incident energy of 121.9 keV from "5"7Co radionuclide. A comparison between the experimental results and the theoretically calculated values shows that the experimental results are, in general, higher than the theoretical values. The measured intensities are regarded to be reported for the first time. (author) 9 refs.; 1 tab.
The main features and advantages of a new low energy nuclear spectroscopic method, the in-beam spectroscopy are described. Results of in-beam spectroscopic experiments performed at the Institute of Nuclear Research (ATOMKI, Debrecen, Hungary) are summarized. Gamma spectra of in-beam produced odd-odd nuclei were measured, gamma-energies were determined. Measurement of gamma-gamma coincidences led to the construction of energy level schemes of the investigated nuclei. Internal conversion electron spectroscopy was used to determine the multipolarities of transitions. A few spectra and level schemes are presented to illustrate the review. Theoretical interpretation of experimental results are briefly summarized. (D.Gy.).
The authors discuss some of the results on the measurements of heavy flavor production at the Tevatron. Heavy flavor production can be used to test QCD over a wide range of quark masses (m{sub b} {approx} 4.5 GeV/c{sup 2} to m{sub t} = 174.3 {+-} 5.1 GeV/c{sup 2}). In addition, it is a background that has to be understood to perform physics measurements in the top sector and Higgs searches. The results reported here are performed using the Run1 data collected at Tevatron ({approx} 100 pb{sup -1}).
The effect of a substrate on the results of measuring tantalum coating thickness in two-layer compositions according to gamma radiation scattered by the substrate is studied. It is shown that by means of an albedo-radiometer realizing the physical model absorber-scatterer one can determine the thickness (application uniformity) of tantalum coatings up to 150-300 #mu#m depending on the substrate material (plexiglas, aluminium, iron, copper). In case of testing coatings on substrates of alloys and high-alloy steels in order to ensure high accuracy of measrurement it is expedient with the above albedo-radiometer to determine the value of the backscattered radiation flux for the substrate before coating application.
Investigations were carried out of radiation level around Daya Bay for three times since the construction and operation Daya bay Nuclear Power Station and Lingao Nuclear Power Station in Guangdong province in the period of 1988 to 2000. As shown by the investigation, the radiation levels both in the field and indoors remains unchanged by and large but slightly higher than before on the roads. Also this paper gives the analysis of variations in radiation levels form site to site and from time to time. It was shown that, for environmental ? radiation levels measurements, typical measuring sites have significant impact on the meaning results. (authors)
In VHTGR (Very High Temperature Gas-cooled Reactor), the radiation plays an important role in heat transfer through the cavity in RCCS (Reactor Cavity Cooling System). We performed the series of experiments to measure the emissivity using the infrared thermometer with wavelength range of 8#approx#14 #mu#m. As the first step, the transmittance of Zinc Selenide (ZnSe) window was measured to estimate the emissivity that can compensate the attenuation effect of window. The kind of gas with various concentrations in the cavity will be released during postulated accidents to the coolant type, so it is essential to estimate the effects of gas on the measurement of emissivity. In this manner we measured the emissivity with the air, the helium and the steam inside chamber. The results represent that the concentration of the air and the helium do not affect the emissivity significantly while ...
A technique and a particular apparatus for an inductive measurement of critical currents as a function of temperature and magnetic field in thin-film superconductors are described. The technique has been found to be particularly useful for high-field A-15 compounds 2 to 3 ..mu..m thick. Samples with lower critical current densities would have to be correspondingly thicker to measure over the same broad range of temperature and field. The design of the apparatus is detailed showing that the film can be taken directly from the deposition chamber and mounted without electrical contacts so samples can be changed easily. The principles of operation are developed based on the Critical State Model. These principles are tested by measurements which verify that the measured value of critical curent is independent of the amplitudes and frequency of the small ac magnetic field which is added to a much larger ...
Detailed spray characteristics were obtained for a small-capacity, pressure-swirl atomizer using an Aerometrics phase-Doppler particle analyzer. Measurements included drop size and velocity distributions, liquid volume fluxes, and air velocities at four axial locations, 25,50,75, and 100 mm, with complete radial traverses at each location. Drop size results were compared with measurements from a Malvern laser-diffraction instrument, and integrated liquid volume fluxes were compared with measured flow rates to estimate measurement uncertainties. Drop sizes measured by the two independent techniques and area-weighted-averaged over the radial traverses at each of the four axial stations varied on average by less than 4 percent. Integrated volume flux measurements by the phase-Doppler instrument at four axial stations differed from the nozzle ...
Optical measurement of the Doppler shift of laser backscatter, using a near-IR, visible, or ultraviolet laser, is potentially more robust and field reliable than coherent, heterodyne measurement with an IR laser. The direct measurement of the displacement of Fabry-Perot interference fringes is possible, but entails expensive, technically challenging, imaging detectors. The 'edge technique' permits Doppler shift measurements with relatively simple detectors and detector electronics, and has been implemented with Fabry-Perot etalons and with atomic line filters. Simple analytical models of the fringe imaging and edge detection techniques are presented, permitting ready calculation of the potential performance of either, for various atmospheric conditions and for various lidar hardware configurations. The predictions of the analytical models are confirmed by computer models, which in turn allow more ...
We have developed a transportable container based direct detection Doppler lidar based on the double-edge molecular technique. The pulsed solid state system was built at the University of Geneva. It was used to make range resolved measurements of the atmospheric wind field as part of the VALID campaign at the Observatoire de Haute Provence in Provence, France in July 1999. Comparison of our lidar wind measurements, which were analyzed without knowledge of the results of rawinsonde measurements made under the supervision of ESA, show good agreement with these rawinsondes. These are the first Doppler lidar field measurements made with an eyesafe direct detection molecular-based system at 355 nm and serve as a demonstrator for future spaceborne direct detection wind systems such as the Atmospheric Dynamics mission. Winds are an important contributor to sea surface temperature ...
Today`s nuclear power plants are marked by increasing needs for non-destructive inspection techniques in preventive maintenance programs. Additionally, it is becoming more important to evaluate residual stress which may be a key parameter for crack propagations in welded pipings. The authors have developed an ultrasonic velocity measurement method which obtains ultrasonic velocity changes by residual stress with a high accuracy. The ultrasonic velocity measurement is composed of three procedures. They are as follows. (1) Highly accurate propagation time measurements; (2) Pipe thickness correction; (3) Residual stress evaluation. The ultrasonic velocity measurements have been applied to the residual stress evaluation of carbon steel welded pipings. Destructive testing using stress strain gauges was done after the ultrasonic non-destructive evaluation of the residual stress. The experimental ...
Subsurface conditions at sites in the coastal plains region of South Carolina were investigated using standard penetration and mechanical quasi-static cone penetration tests. The penetration test results are compared with measured static axial pile capacity. The cone penetration test results are compared with stratigraphy and soil types encountered at each site. Results show that with certain limitations, cone penetration test results can be used to assess general stratigraphy and soil type and predict static axial pile capacity with reasonable accuracy.
In the future, the demand for energy is predicted to grow and more countries plan to utilize nuclear energy as their source of electric energy. This gives rise to many important issues connected to nuclear energy, such as finding methods that can verify that the spent nuclear fuel has been handled safely and used in ordinary power producing cycles as stated by the operators. Gamma ray spectroscopy is one method used for identification and verification of spent nuclear fuel. In the specific gamma ray spectroscopy method called gamma scanning the gamma radiation from the fission products Cs-137, Cs-134 and Eu-154 are measured in a spent fuel assembly. From the results, conclusions can be drawn about the fuels characteristics. This degree project examines the possibilities of using alternative measuring approaches when using the gamma scanning method. The focus is on examining how to increase the quality of the ...
In the future, the demand for energy is predicted to grow and more countries plan to utilize nuclear energy as their source of electric energy. This gives rise to many important issues connected to nuclear energy, such as finding methods that can verify that the spent nuclear fuel has been handled safely and used in ordinary power producing cycles as stated by the operators. Gamma ray spectroscopy is one method used for identification and verification of spent nuclear fuel. In the specific gamma ray spectroscopy method called gamma scanning the gamma radiation from the fission products Cs-137, Cs-134 and Eu-154 are measured in a spent fuel assembly. From the results, conclusions can be drawn about the fuels characteristics. This degree project examines the possibilities of using alternative measuring approaches when using the gamma scanning method. The focus is on examining how to increase the quality of the ...
We analyze the average of weak values over statistical ensembles of pre- and post-selected states. The protocol of weak values, proposed by Aharonov et al. [Phys. Rev. Lett. 60 (1988) 1351], is the result of a weak measurement conditional on the outcome of a subsequent strong (projective) measurement. Weak values can be beyond the range of eigenvalues of the measured observable and, in general, can be complex numbers. We show that averaging over ensembles of pre- and post-selected states reduces the weak value within the range of eigenvalues of Formula Not Shown . We further show that the averaged result expressed in terms of pre- and post-selected density matrices, allows us to include the effect of decoherence.
Traffic characterization is an important means for Internet Service Providers (ISPs) to adapt and to optimize their networks to the requirements of the customers. Most network measurements are performed in the backbone of these ISPs, showing both, residential and business Internet traffic. However, the traffic characteristics of business and home users differ significantly. Therefore, we have performed measurements of home users at a broadband wireless access service provider in order to reflect only home user traffic characteristics. In this paper, we present the results of these measurements, showing daily traffic fluctuations, flow statistics as well as application distributions. The results show a difference to backbone traffic characteristics. Furthermore, we observed a shift from web...
This study is an attempt to measure the quantities of elements in a composite by irradiating that composite with #gamma#-rays of various energies and detecting the transmitted radiation through the composite. A previous knowledge of the number of the elements and their attenuation coefficients is required. The quantities are calculated by solving the matrix of a linear system of equations. A computer program was developed to select the best combinations of the available energies. Five criteria were established to determine these energy combinations: (i) the determinant of the attenuation coefficient matrix; (ii) the condition number, (iii) the number of times the solution of the matrix leads to acceptable results; (iv) the indicator, (a new concept); (v) the standard deviations of the results. The intended application of this technique in medicine is to measure the bone mineral content of the skeleton. ...
This article describes the laser Thomson scattering principle and the developed system on HL-2A device. The high power Q-switch Nd:YAG laser, with a wavelength of 1064 nm, can sufficiently satisfy the measurement requirement. The polycromator consisting of avalanche photo-diodes(APD) and narrow band interference filters, can effectively improve the measurement of scattering light. The electron temperature is deduced by error-weighted lookup table method, which improves the data- processing speed or efficiency. Finally, the experiment results of the one-point electron temperature during different discharges of plasma are presented. (authors)
The advance in laser-plasma acceleration techniques pushes the regime of the resulting accelerated particles to higher energies and intensities. In particular the upcoming experiments with the FLAME laser at LNF will enter the GeV regime with almost 1nC of electrons. From the current status of understanding of the acceleration mechanism, relatively large angular and energy spreads are expected. There is therefore the need to develop a device capable to measure the energy of electrons over three orders of magnitude (few MeV to few GeV) under still unknown angular divergences. Within the PlasmonX experiment at LNF a spectrometer is being constructed to perform these measurements. It is made of an electro-magnet and a screen made of scintillating fibers for the measurement of the trajectories of the particles. The large range of operation, the huge number of particles and the need to focus the divergence ...
The ground state masses of thirty-nine neutron-rich nuclei from [sup 51]Ca to [sup 72]Ni have been measured using the Time-of-Flight Isochronous (TOFI) spectrometer. Eight of these masses have been measured for the first time and thirty-one are remeasurements of neutron-rich nuclei previously reported. Good agreement between these results and a previous TOFI experiment was observed except for the most neutron-rich isotopes of vanadium through iron with the present results being more bound and in better agreement with theory. The low binding energy of [sup 68]Ni, as indicated by an unreasonably low two-neutron separation energy, suggests the presence of a high-lying, long-lived isomeric state in this nucleus. (orig.)
The ground state masses of thirty-nine neutron-rich nuclei from "5"1Ca to "7"2Ni have been measured using the Time-of-Flight Isochronous (TOFI) spectrometer. Eight of these masses have been measured for the first time and thirty-one are remeasurements of neutron-rich nuclei previously reported. Good agreement between these results and a previous TOFI experiment was observed except for the most neutron-rich isotopes of vanadium through iron with the present results being more bound and in better agreement with theory. The low binding energy of "6"8Ni, as indicated by an unreasonably low two-neutron separation energy, suggests the presence of a high-lying, long-lived isomeric state in this nucleus. (orig.).
This paper studies the effect upon the thermoluminescence (TL) signal of four feldspar samples of exposing them to infrared stimulation, as occurs during infrared-stimulated luminescence (IRSL) measurement. Together with pulse annealing measurements these results are used to show which part of the TL signal is removed by exposure to IR and which part is directly related to the IRSL signal that is observed. When the samples are preheated prior to measurement in order to remove any low-temperature (< 200"oC) TL signals, a linear relationship is observed between the amount of TL that is lost and the IRSL light sum that is produced. The IRSL light sum is consistently four times larger than the amount of TL that is lost. Three possible explanations are proposed for this, but no conclusive evidence could be obtained to support any of them. A close similarity is observed in the pulse annealing ...
Harmonics bred from loads are mainly odd order because the current waveforms have half-wave symmetry. Since the even harmonics are negligibly small, they generally are not measured in electric power systems. However, even harmonics were measured at a 500/275/154 kV substation in Hokuriku Electric Power Company after a transmission line fault was corrected. The even harmonics caused malfunctions of protective digital relays because the relays used 4th harmonics at the input filter as the automatic supervisory signal. This paper describes mechanisms of generation of the even harmonics by comparing the measured waveforms with the ATP-EMTP simulation results. Analysis of these results has clearly shown that there are three different mechanisms of generation of even harmonics. The first mechani...
Radon concentration measurements in atmosphere were taken in years from 1997 to 1999 in Milan and at pre-alpine sites located north of Lombardy. In this paper the results of measuring campaigns and a comparison of radon levels observed in the hilly area north of the town and on the pre-Alps are reported. The general criteria of the measurements and the interpretative models of radon concentration are presented. The Lake Maggiore area shows evidence of a great nocturnal stability and frequent formation of Nocturnal Stable Layer. The peculiar findings in the high altitude stations confirm the use of radon as an indicator of atmospheric dispersion of pollutants in an area with complex orography. The afternoon minimum values are concordant for the different stations: this implies a remixing in afternoon hours over the whole area investigated.
Total potassium was assayed in 150 normal weight and obese females (cervical carcinoma-52, endometrial carcinoma-25 and breast cancer-73) by measurements of 40K spontaneous radiation in a low-background chamber. Control group included 30 healthy and 25 obese females. Computations of body cell and extracellular mass and fat were carried out on the basis of the said measurements. Extracellular fluid volume was measured in 38 patients by X-ray fluorescence method using sodium bromide. The results pointed to a body cell mass deficit matched by increased extracellular mass due to a higher fat level in patients with breast, endometrial and cervical carcinoma. The said correlation was particularly pronounced in obese patients. The beneficial effect of treatment was more often observed in patients with normal body weight. PMID:3739295
The radiative heat loss from a surface is determined by its total hemispherical emittance, which consequently plays an important role in aerospace and solar applications. This study compares emittances measured calorimetrically with values derived from near normal incidence spectral reflectance measurements. This optical derivation is based on a number of assumptions which limit the accuracy if not sufficiency fulfilled. These assumptions include sample specularity, a straybody character beyond the range of measurement, only small variations of emittance with temperature, and a perfectly smooth sample surface. The comparison of calorimetrically and optically derived emittance performed in this study not only quantifies the errors introduced by insufficient fulfillment of the assumptions but also identifies which assumption causes the dominant error. The calorimetric emissometer, constructed for this study and based on a ...
The International Linear Collider (ILC) and other proposed high energy e{sup +}e{sup -} machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 10{sup -4}. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006-2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5 {center_dot} 10{sup -4} was measured, which is satisfactory for most scenarios. We also report on the operational experience with the chicane-based spectrometer and suggest ways of improving its performance.
The electrochemical/spectroscopic integrated measurement system was designed and set up for spectro-electrochemical measurements of lanthanide and actinide ions in high temperature molten salt media. A compact electrochemical cell and electrode system was also developed for the minimization of reactants, and consequently minimization of radioactive waste generation. By applying these equipment, oxidation and reduction behavior of lanthanide and actinide ions in molten salt media have been made. Also, thermodynamic parameter values are determined by interpreting the results obtained from electrochemical measurements. Several lanthanide ions exhibited fluorescence properties in molten salt. Also, UV-VIS measurement provided the detailed information regarding the oxidation states of lanthanide and actinide ions in high temperature molten salt media
It is a traditional method to diagnose electron-cyclotron-resonance (ECR) plasma source, using a single probe to measure the current-voltage curve of the plasma, based on which and theoretic formula the plasma density can be computed. The article adopts a Langmuir probe having a role of emission electrons to measure two different current-voltage curves with and without emission. It is ease to get the plasma potential via the inflexion of the two curves and compute directly various physical quantities by the assistant computer, such as electron temperature, electron/ion density, plasma potential etc. The deviation is about percent 1.8 between the measurementresults by traditional and the new method, but the latter has higher efficiency. (authors)
Polarization measurements are allowing the electric to magnetic form factor ratio of the proton to be determined with unprecedented precision. Recent results indicate that there is a large deviation from unity in the proton form factor ratio around Q{sup 2}{approx_equal}0.35 GeV{sup 2}. Furthermore, the deviation from unity is attributed to a deviation of the electric form factor from standard fits and calculations. A new, partially completed, experiment will significantly improve the existing data and will determine the presence, if any, of a narrow structure in the form factor ratio. The new measurement, combined with the expected high precision cross section measurements, will allow the extraction of individual form factors with unprecedented accuracy at low Q{sup 2}.
Making use of a back-to-back type double fission chamber and a lead slowing-down spectrometer driven by a 46 MeV electron linear accelerator, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40 % full width at half maximum. Each of the measuredresult has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, whose evaluated and measured data were broadened by the energy resolution function of the spectrometer.
Making use of a back-to-back type double fission chamber and a lead slowing-down spectrometer driven by a 46 MeV electron linear accelerator, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40% full width at half maximum. Each of the measuredresult has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, whose evaluated and measured data were broadened by the energy resolution function of the spectrometer. (author)
Neutron-induced soft error rates (SER`s) of subhalf-micron CMOS SRAM and Latch circuits were studied both experimentally and analytically to investigate cosmic ray neutron-induced soft errors (SE`s). Because the neutron beam used in the measurement has an energy spectrum similar to that of sea-level atmospheric neutrons, the SER data corresponds to those induced by cosmic ray neutrons. The {alpha}-particle induced SER`s were also measured for comparison with the neutron-induced SER`s. Neutron-induced SE`s occurred in both circuits. On the other hand, {alpha}-induced SE`s occurred in SRAM, but not in the Latch circuit. The measured SER`s agreed with simulated results. The authors discussed the significance of how cosmic ray neutrons affects CMOS circuits at ground level.
We investigate the possibility of implementing a given projection measurement using linear optics and arbitrarily fast feedforward based on the continuous detection of photons. In particular, we systematically derive the so-called Dolinar scheme that achieves the minimum-error discrimination of binary coherent states. Moreover, we show that the Dolinar-type approach can also be applied to projection measurements in the regime of photonic-qubit signals. Our results demonstrate that for implementing a projection measurement with linear optics, in principle, unit success probability may be approached even without the use of expensive entangled auxiliary states, as they are needed in all known (near-)deterministic linear-optics proposals.
Objectives To investigate the feasibility and reproducibility of measurements of nasal bone length using a three-dimensional (3D) ultrasound in the first trimester. Methods In a prospective study, 118 consecutive pregnant women attending for Down syndrome screening at 11-13 + 6 weeks were recruited. They had successful fetal nasal bone measurement by two-dimensional (2D) ultrasound by four operators. Three-dimensional volumes were recorded in the mid-sagittal plane of fetal profile by the fifth operator and examined using multiplanar techniques. Another independent investigator randomly compared his measurements with one of the four operators. Results In the subsequent 3D examination, the nasal bone length could be examined in 94 cases (79.7%). The mean difference between the 2D and 3D mea...
A dynamic control rod worth measurement was performed for control bank D, C, B, and A of Yonggwang unit 1 cycle 14 during its low power physics test. MASTER was used for three-dimensional core kinetics calculations required to convert excore detector signal into static rod worth, using the same modeling and cross sections as ANC which was used for the core static design. A signal curve fitting method was proposed to solve a low signal problem due to large amount of rod worth, which leads to the distortion of resulting static worth. The static worths measured in this test well agreed with the predicted worth of design within {+-}15% which is a test requirement of rod worth measurement.
A dynamic control rod worth measurement was performed for control bank D, C, B, and A of Yonggwang unit 1 cycle 14 during its low power physics test. MASTER was used for three-dimensional core kinetics calculations required to convert excore detector signal into static rod worth, using the same modeling and cross sections as ANC which was used for the core static design. A signal curve fitting method was proposed to solve a low signal problem due to large amount of rod worth, which leads to the distortion of resulting static worth. The static worths measured in this test well agreed with the predicted worth of design within #+-#15% which is a test requirement of rod worth measurement.
To investigate the characteristics of a reactor and a neutron generator, a small scintillation detector with an optical fiber with ThO_2 has been developed to measure fast neutrons. However, experimental facilities where "2"3"2Th can be used are limited by regulations, and S/N ratio is low because the background counts of this detector are increase by alpha decay of "2"3"2Th. The purpose of this study is to develop a new optical fiber detector for measuring fast neutrons that does not use nuclear material such as "2"3"2Th. From the measured and calculated results, the new optical fiber detector which uses ZnS(Ag) as a converter material together with a scintillator have the highest detection efficiency among several developed detectors. It is applied for the measurement of reaction rates generated from fast neutrons; furthermore, the absolute detection efficiency of this detector ...
Research on the emotion of shame has increased significantly in recent years. However, there remains a need for more psychometrically sound measures of shame, including measures of shame in response to specific, idiographic experiences. The Shame Inventory was developed in order to assess both global feelings of shame as well as shame in response to specific life events or personal characteristics. Two studies were conducted to determine the preliminary psychometric properties of the Shame Inventory. Across both studies, results indicate that the inventory has high internal consistency, test-retest reliability, construct validity, and predictive validity. The Shame Inventory holds promise as a new measure designed to assess both global feelings of shame as well as specific shame-eliciting ...
A 20-MeV proton accelerator is developed by Proton Engineering Frontier Project (PEFP) at Korea Atomic Energy Research Institute (KAERI). The 20MeV accelerator consists of 50keV proton injector, 3MeV RFQ (Radio frequency Quadrupole), 20MeV DTL (Drift Tube Linac) and 20MeV beam line. The beam profile was measured at the end of the 20MeV beam line with wire scanner. Moreover the beam emittance was calculated from the quad scan method using beam line quadrupole magnets. In this paper, the beam profile measurementresults are presented and the emittance measurement from the quad scan method is discussed
Radon concentration measurements in atmosphere were taken in years from 1997 to 1999 in Milan and at pre-alpine sites located north of Lombardy. In this paper the results of measuring campaigns and a comparison of radon levels observed in the hilly area north of the town and on the pre-Alps are reported. The general criteria of the measurements and the interpretative models of radon concentration are presented. The Lake Maggiore area shows evidence of a great nocturnal stability and frequent formation of Nocturnal Stable Layer. The peculiar findings in the high altitude stations confirm the use of radon as an indicator of atmospheric dispersion of pollutants in an area with complex orography. The afternoon minimum values are concordant for the different stations: this implies a remixing in afternoon hours over the whole area investigated.
Amperostatic coulometry was applied for the thickness measurement of Sn-Ag hot dip coatings, which comprise an extended Sn-Cu interdiffusion layer. Complementary measurements, notably weight loss, X-ray photoelectron spectroscopy, energy-dispersive X-ray spectroscopy, X-ray fluorescence (XRF), and dynamic secondary ion mass spectroscopy were performed in order to obtain a better interpretation of the coulometry results. Based on the experimental results presented in this article, the three potential changes observed during coulometry measurements are ascribed to (i) the entire dissolution of pure Sn, (ii) the formation of a CuCl salt layer, and (iii) the surface passivation. The measurement of the pure Sn mass is well reproducible despite strong coating thickness variations detected by XRF. Several experimental problems, in particular, a coating undercutting, ...
A pilot project was started in 1977 over the Lake Superior basin to measure water storage on the land area using aerial gamma-ray spectrometry to provide hydrologic information for forecasting inflow to the lake. Two airborne surveys were made, respectively in November 1977 and March 1978 which provided estimates of the increase in snow water equivalent between these surveys. The basin is located on the Canadian Shield and consequently, the gamma radiation count rate is quite variable. The airborne results are compared with ground measurements on selected flight lines and show generally good agreement. Two equipment calibrations in the Ottawa area provided inconsistent parameter values which are consequently also reflected in the results over the Lake Superior basin. The project has demonstrated to-date that the technique can be developed into an operational system for measuring ...
The detection efficiency of gamma scanning system in irradiated materials examination facility has been measured. Gamma-ray sources used in this experiment are Cs-Co standard sources a PWR spent fuel rod in which {sup 134}Cs and {sup 154}Eu peaks are clearly identified in the energy region of 500 to 1,600 keV. The distance between source and detector is about 1.6 m. A slit type collimator with 3 mm-width window and 30 mm-thick lead block are installed between source and detector. The detector is a HPGe detector. This equipment is mainly used in gamma scanning of irradiated nuclear fuel. The measured detection efficiency seems to be 1.89 x 10{sup -6} % for 1 MeV gamma-ray. With these results the activities of unknown sources could be measured. This results are expected to be used in the measurement of the absolute distribution of gamma emitting nuclides in ...
Each of the two LHC injection kicker magnet systems must produce a kick of 1.3 T.m with a flattop duration variable up to 7.86 microseconds, and rise and fall times of less than 900 ns and 3 microseconds, respectively. A kicker magnet system consists of four 5 Ohm transmission line magnets with matching terminating resistors, four 5 Ohm Pulse Forming Networks (PFN) and two Resonant Charging Power Supplies (RCPS). Nine PFNs, together with associated switch tanks, and dump switch terminating resistors have been built at TRIUMF and all have been tested at high voltage (54 kV) to ensure that the performance is within specification. This paper describes the HV measurements, compares these results with low voltage measurements and analyses the pulse performance of the PFNs. The measurements are compared with results from PSpice simulations and small discrepancies between the predictions ...
Examination of measurement invariance provides a powerful method to evaluate the hypothesis that the same set of psychological constructs underlies a set of test scores in different populations. If measurement invariance is observed, then the same psychological meaning can be ascribed to scores in both populations. In this study, the measurement model including core and supplementary subtests of the Wechsler Adult Intelligence Scale-Fourth edition (WAIS-IV) were compared across the U.S. and Canadian standardization samples. Populations were compared on the 15 subtest version of the test in people aged 70 and younger and on the 12 subtest version in people aged 70 or older. Results indicated that a slightly modified version of the four-factor model reported in the WAIS-IV technical manual provided the best fit in both populations and in both age groups. The null hypothesis of ...
The computer program is developed based on Visual C++, which is equipped with a user-friendly interface of the input/output(I/O) and a display function for the measuring conditions. This program consists of three parts which are the port communication, PLC(Programmable Logic Controller) and the MCA(Multi Channel Analyzer) control parts. The communication type between the CPU of the PLC module box and the computer is selected as be the Rs-232 asynchronous type and the thread method is adapted in the development of the first part of the program. The PLC-related program has been developed so that the data communication between the PLC CPU and the computer could be harmonized with the unique commands which have already been defined in the PLC. The measuring space and time intervals, the start and end ROI(region of interest) values, and the allowable error limitation are input at each measurement in this program. Finally the ...
The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center (TMC) at the DOE Grand Junction Projects Office (GJPO) in Grand Junction, Colorado, to standardize, calibrate, and compare measurements made in support of DOE remedial action programs. Outdoor radon concentration measurements were made by the TMC in Shiprock, New Mexico, to compare two different methods of measuring radon in an attempt to determine the feasibility of using passive alpha-track detectors to assess the adequacy of remedial action undertaken at the Shiprock uranium mill tailings pile. The results of the first three quarters of monitoring have been detailed in previous reports. An analysis of the data from the fourth quarter of monitoring at Shiprock reveals a somewhat poorer correlation between the two sets of measurements ...
Measurements of human joint motion frequently involve the use of opto-electronic and other motion analysis systems where some type of makers are used to establish joint motion within a global reference coordinate frame. Typically, this global reference coordinate frame is chosen to be most convenient for the person carrying out the experiment in which the joint motion is measured, and Euler angles are chosen as the measure of joint motion. Results, however, may be quite arbitrary and therefore rendered meaningless if the reference frame is not properly chosen with respect to the physical joint axis. In order to make a proper choice of coordinate axes in the reference frame, one must take into consideration both the location and the orientation of die physical joint axis relative to the reference frame`s axes. In nature, joint axes can exist at any orientation and location relative to an arbitrarily ...
Fine ceramics center (JFCC) succeeded in the higher precision of thermal diffusivity measurement by the laser flash. This results are part of 'the research on thermophysical property measurement technique and standard substance of the functional material' by the intelligent establishing of a base promotion system of Science and Technology Agency. Cooperative research. thermal diffusivity with Natl. Res. Lab. of Metrology is one of the representative thermophysical property. The speed in which a heat transmits of the material is shown, and it is indispensable to the design of the high-temperature member subject. JFCC heralds the world as a standard substance for the thermal diffusivity measurement; 'TD-AL' using the alumina material is developed and is supplied in the spring in last year. Laser flash which uses laser beam for the heat source is general for the ...
Tensor polarization of "6Li(2.18 MeV, 3"+) nucleus at inelastic scattering of #alpha# particles for #THETA#_l_a_b=45 deg angle is measured. The results are described by the calculations in terms of Born approximation of distorted waves with internucleonic interaction realistic potential.
The author describes the results of post-test analyses of PANDA transient (M-series) tests M2 and M3. The purpose of the PANDA post-test analysis activity is to demonstrate that TRACG is applicable for the calculation of long-term SBWR containment response to a LOCA. Comparisons between TRACG predictions and test measurements are presented and discussed in the dual context of what the test results show and the capability of TRACG to predict their key features
There is need of pressure surge analyses when valves or pumps are activated or piping systems fail (pipe rupture). Based on actual problems the influences of boundary conditions upon fluid simulation results are discussed. Hints concerning realistic dynamic analyses of piping systems are presented. Some of the simulations results are compared with measurements. (orig.)
It is proposed to measure the spot sizes and polarization of #gamma# beams of future #gamma#e and #gamma##gamma# colliders detecting e"+e"- pairs produced as a result of interaction of high energy #gamma# quanta with density modulated and not modulated laser photons. The quantum electrodynamics cross sections, necessary numerical results as well as a short comparison of the proposed method with some other methods are given. (orig.).
The calculations with the broad-group cross-section library Bugle-96, and atom displacement (dpa) cross sections for iron, both derived from ENDF/B-VI data, result in higher calculated fast neutron fluxes, better agreement of calculations with radiometric dosimeter measurements, and significantly slower dpa rate attenuation through pressure vessel walls relative to the results with their predecessors: the Sailor library and ASTM iron dpa cross sections.
The results of a time-resolved study of the avalanche and streamer formation phases leading to breakdown in atmospheric nitrogen and dry air. Results of experiments and two-dimensional simulations are presented. It is shown what processes are responsible for the formation of a streamer. The trends of externally measured quantities correspond with those predicted by our model. 3 figs., 5 refs.
The electron beam ion source (EBIS) at Texas A and M University was constructed and is currently undergoing tests on the injection and transmission of the electron beam through the solenoid. Results of computer simulation of the electron beam are presented, as well as measurements of electron beam profiles using a pinhole beam analyzer.
Three instruments for measuring local velocities in liquid-metal MHD experiments for fusion blanket applications are being evaluated. The devices are used in room-temperature NaK experiments to measure three-dimensional flow field patterns anticipated in complex blanket geometries. Hot film anemometry, a standard technique in ordinary fluids, is being used, as well as two developmental devices. One is called the Liquid Metal Electromagnetic Velocity Instrument (LEVI), and performs essentially as a local dc electromagnetic flow meter. The third device, a Thermal Transient Anemometer (TTA) is a rugged, yet relatively simple device, which measures local velocity through the mechanism of convective heat transfer, in some ways similar to hot-film anemometry. Results are presented showing the kinds of data collected this far with each instrument. Measurements include both local velocity ...
The project is described, the motivation for the research and the microclimate is defined in relation to both building physics research and applications. Air temperatur, air humidity, solar radiation and air velocity are briefly considered, whilst driving rain and long-wave radiation are described in more detail. Convective heat transfer and surface coefficients are discussed, although they are not microclimatic factors, merely resulting from combinations of such factors. They are included as they are important in relation to transfer of heat and moisture at the surface of the building envelope. Driving rain measurement is the main area of interest, including development of measurement equipment. Long-wave irradiation is measured and compared with empirical formulae from the literature. Window convection heat transfer is another main area of interest. Nocturnal convective heat transfer from a double ...
In the case of total skin electron therapy without the beam guide, the electron beam is scattered just outside the gantry exit, dose uniformity in the field is broken, and dose is spread outside the light field. The aims of this study were to measure the mean energy of the off-axis incident electron beam without the beam guide and to establish a reference for the clinical situation. For the measurement, a 4 MeV electron beam was selected among several energies from the linear accelerator. A scintillating fiber beam energy monitor measured the mean energy of the incident electron beam. This energy monitor is a small, light-weight piece of equipment composed of a wedge absorber, scintillation fiber, and photodiode. We found the relationship between electron energy and the indicated value of the energy monitor by means of the estimation of correction factors for five different kinds of electron energy. The preferable linear ...
A risk-neutral method is always used to price and hedge contingent claims in complete market, but another method based on utility maximization or risk minimization is wildly used in more general case. One can find all kinds of special risk measure in literature. In this paper, instead of using market modified risk measure, we use a kind of risk measure induced by g_\\Gamma-solution or the minimal solution of a Constrained Backward Stochastic Differential Equation (CBSDE) directly when constraints on wealth and portfolio process comes to our consideration. Such g_\\Gamma-solution and the risk measure generated by it is well defined on appropriate space under suitable conditions. We adopt the inf-convolution of convex risk measures to solve some optimization problem. A dynamic version risk measures defined through g_\\Gamma-solution and some similar ...
The lidar group in Lund has performed many DIAL measurements with a mobile lidar system that was first described in 1987. The lidar system is based on a Nd:YAG-pumped dye laser. During the last few years the lidar group has focused on fluorescence imaging and mercury measurements in the troposphere. In 1994 we performed two campaigns: one fluorescence imaging measurement campaign outside Avignon, France and one unique lidar campaign at a mercury mine in Almaden, Spain. Both campaigns are described in this thesis. This thesis also describes how the mobile lidar system was updated with the graphical programming language LabVIEW to obtain a user friendly lidar system. The software controls the lidar system and analyses measured data. The measurementresults are shown as maps of species concentration. All electronics and the major parts of the program are described. ...
The extensive work on the measurement technology of total and local flow rates in BWR core has been performed using in-core neutron fluctuating signals. Based on a large amount of actual data acquired from commercial BWR plants in operation, physical interpretation was discussed on the transit time of the neutron fluctuating signals. The new findings against the logical inconsistency of the transit time between the different LPRM detector positions lead to a promised core flow measurement algorithm using in-core neutron fluctuating signals. The advanced on-line core flow measurement system was developed and tested during the startup phase of the first ABWR. The measurement test results demonstrate the present core flow measurement system within the errors of 5 through 10% over the wide operating area besides the capability for the local void fraction and ...
The predicted results of INDAC code were compared with measured {sup 3}H concentrations in air and pine-needle around the Wolsung site. The optimal sets of input data to INDAC were in addition selected by comparing the measured values with the predicted values of INDAC based on various conditions such as the release modes of effluents into the environment, the classification of wind classes, and the consideration of terrain. The predicted {sup 3}H concentrations in air and pine-needle were shown to have good agreement with measured values, although there are some limitations such as uncertainties in measured values, complex topology around the site, and the land-sea breeze effects. The assumption on the {sup 3}H behavior in vegetables or plants that the ratio of {sup 3}H concentration in plant water to {sup 3}H concentration in atmospheric water is 1/2 was shown to be conservative ...
The predicted results of INDAC code were compared with measured "3H concentrations in air and pine-needle around the Wolsung site. The optimal sets of input data to INDAC were in addition selected by comparing the measured values with the predicted values of INDAC based on various conditions such as the release modes of effluents into the environment, the classification of wind classes, and the consideration of terrain. The predicted "3H concentrations in air and pine-needle were shown to have good agreement with measured values, although there are some limitations such as uncertainties in measured values, complex topology around the site, and the land-sea breeze effects. The assumption on the "3H behavior in vegetables or plants that the ratio of "3H concentration in plant water to "3H concentration in atmospheric water is 1/2 was shown to be conservative in terms of the audit ...
An experimental apparatus has been built that allows direct measurement of the oil film thickness in a bearing that is subjected to dynamic loads and shaft speeds representative of those occurring in automotive engine connecting rod, big-end bearings. Dynamic motion of the shaft, relative to the bearing, is measured as a function of shaft rotational angle, using non-contact, eddy-current probes. A computer based data acquisition system is used to measure, record, and analyze the journal position in the bearing. The test bearing is 63.5 mm in diameter by 25.4 mm long, and is loaded using a servo-hydraulic actuator rated at 98.3 kN. The journal has an operating speed of 500 to 3800 rpm. The actuator is controlled by a computer-generated waveform that can duplicate load profiles developed by various engines operating at a wide range of conditions. Measurements taken with the shaft statically loaded show ...
The L-shell x-ray intensity ratios I(L_#beta#)/I(L_#alpha#) and I(L_#gamma#)/I(L_a_l_p_h_a) for elements with 73 #<=# Z #<=# 83 have been measured at photon incident energies of 17.8, 25.8 and 46.9 keV. The emitted x-rays were measured with a Si(Li) detector system. The results for Re, Pt and Tl are being reported for the first time. A comparison is made of the experimental results with the calculated values obtained by using the theoretical x-ray emission rates, subshell ionisation cross sections, subshell fluorescence yields and Coster-Kronig transition probabilities. The experimental results are in reasonable agreement with the theoretical values. (author).
Photoluminescence spectroscopy measurements were carried out for silicon 50{mu}m BSFR space solar cells irradiated with 1MeV electrons with a fluence exceeding 1 x 10{sup 16} e/cm{sup 2} and 10MeV protons with a fluence exceeding 1 x 10{sup 13} p/cm{sup 2}. The results were compared with the previous result performed in a relative low fluence region, and the radiation-induced defects which cause anomalous degradation of the cell performance in such large fluence regions were discussed. As far as we know, this is the first report which presents the PL measurementresults at 4.2K of the large fluence radiation irradiated silicon solar cells. (author)
A photoacoustic (PA) imaging system based on an ultrasonic Fresnel zone plate (FZP) transducer is developed for the purpose of imaging biological tissue. This FZP transducer has a two-zone negative zone plate piezoelectric material pattern, and an optical fibre is integrated with the transducer on the symmetric axis of the zone plates to deliver laser pulses to the sample. The focal characteristic of the FZP transducer is analysed by theoretical prediction and experimental measurement, and the measuredresults are in good agreement with the predicted results. The limited-field back-projection deconvolution algorithm combined with the coherence-factor weighting technique is used to reconstruct the optical absorption distribution. The experiments were performed with phantoms and the blood vessels of chicken embryo chorioallantoic membrane. The results demonstrate that PA imaging using ...
The induced radioactivity in the construction materials of a Cockcroft-- Walton type neutron generator was measured. Major activation products (/sup 24/ Na, /sup 28/Al, /sup 56/Mn, /sup 64/Cu, /sup 65/Ni, /sup 69m/Zn, /sup 88/Rb /sup 91/Sr /sup 101/Mo, /sup 187/W/ and resulting doses are tabulated. Results show that the highest gamma activities would be observed in the fluorescent bulbs, copper pipe, aluminum lattice rod, and the aluminum pipe clamp. Thermoluminescent dosimeter readings yield the highest doses for the copper pipe tee, copper pipe, and aluminum lattice rod. Results of measuremerts of the neutron and gamma dose profiles of the facility are shown. However the indication is clearly that the tritium target, compared to other components, is the major source of radiation both during and after shutdown. (UK)
This paper presents the results of the degree of irreversible changes of dielectric properties of vacuum circuit breakers with CuCr and CuBi contacts before and after short-circuit breaking operations. Tests of dielectric properties were performed on four different types of switching vacuum chamber with RMF electrodes in the form of a spiral disk with slots. The paper describes the configuration of measuring system for determining the dielectric properties of circuit breakers with DC, AC and pulse voltage. It also describes the measuring procedure. The results were analyzed and the experimentally obtained random variable breakdown voltage is found to belong to Weibull distribution in all cases. Based on these results it was found that for the vacuum circuit breakers with CuCr contacts and ...
The two-sonde neutron-logging device RKS-2 registers the ratios of the indications of two sondes and is scaled in units representing the total water content of pure limestone when saturated with fresh water. When analyzing the results of the measurements in real wells, it is necessary to calculate the effect of well- and strata conditions on the results of porosity determination. The results of simulated measurements are presented, on the basis of which correction factors are immediately determined for the calculation of the effect of the diameter of the well, and the effect of the mud cake on the well wall. A nomogram is constructed and substantiated; its purpose is the calculation of the effect of the following on the RKS-2 indication: the diameter of the well, the mud cake on the well wall, the density of the drilling solution, temperature, pressure in the well, and the lithology ...
The LAHET code system calculations and experimental results for proton interactions with an energy <50 MeV are compared. For these energies, the theories behind the LAHET models are not applicable. Three quantities compared are (a) the magnitude of the neutron yield generated through proton interactions, (b) the energy and angular distributions of the resultant neutrons, and (c) the residual nuclei produced by proton interactions (spallation products). The comparisons are for protons incident on iron and copper, except in the case of the energy and angular distributions, which are calculated only for iron. The neutron yields predicted by LAHET agree with published measurements to within 50% for both materials. For iron, the predicted energy and angular distributions agree to within a factor of 3. Finally, the predicted spallation product yields of both materials agree with measurements to within a ...
Existing test procedures for measuring and rating thermal performance require the determination of the angular response of collectors in order to account for nonnormal incident beam irradiance. Angular response measurements for four different types of collectors, each type tested by three different laboratories, are presented and analyzed. Substantial differences, both within and between laboratories, are reported for the same type collectors. An analysis of the measurement procedure shows that experimentally determined angular response parameters are subject to relatively large uncertainties. The problem results to a large extent from measuring collector efficiencies at non-normal incident angles where measurement uncertainty is of the same order of magnitude as the efficiency reduction attributable to these off-normal angles. Other factors which can affect ...
Thermodynamic states encountered during combustion of Aluminum powder in Shock-Dispersed-Fuel (SDF) explosions were analyzed with the Cheetah code. Results are displayed in the Le Chatelier diagram: the locus of states of specific internal energy versus temperature. Accuracy of the results was confirmed by comparing the fuel and products curves with the heats of detonation and combustion, and species composition as measured in bomb calorimeter experiments. Results were fit with analytic functions u = f(T) suitable for specifying the thermodynamic properties required for gas-dynamic models of combustion in explosions.
A study was performed to investigate the size of pharyngeal cavity and sexual differences between Korean adult mal e and female by introducing linear analysis of the lateral cephalogram. The radiograms were composed of 46 adult male aged 24.64 and 52 adult female aged 22.74 respectively. In order to study and measure the pharyngeal area, the following skeletal landmarks were selected: S,N,A,Ptm, B,H,H', M ,S-N, FH and CV, and the angle CV-FH was measured to provide a factor for correction of error resulting from improper he ad positioning of subjects, especially in the relative positions of A and H, while radiography. All points to be measured were projected at right angles to the Frankfort plane. For the purpose of measuring the anteroposterior dimensions of pharyngeal cavity the distances were measured in A-Ptm, A-S, S-Ptm and CV-H, and vertical ...
In conducting aircraft surveys for uranium, it is found that temperature inversions can give spurious results because they promote accumulation of radon gas in the atmosphere. The "2"1"4Bi (daughter product of radon) gamma-rays detected from the atmosphere-borne radon are difficult to separate from the "2"1"4Bi gamma-rays originating from the ground, and providing a signature for uranium deposits. The purpose of the present study was to examine the feasibility of making remote temperature soundings of the atmosphere below a low-flying aircraft (140 m or less above ground) by the inversion of radiance measurements taken in the 15-micron carbon dioxide absorption band. Such measurements would identify those temperature inversion conditions possibly leading to an unacceptably large background of gamma-rays from the atmospheric radon. Thus, the incidence of spurious aerial survey data could be greatly reduced. An atmospheric ...
Precise measurements of the single spin asymmetry AN, and the double spin asymmetry ANN, in proton-proton (pp) elastic scattering in the region of four-momentum transfer squared 0.0012 have been performed using a polarized atomic hydrogen gas jet target and the Relativistic Heavy Ion Collider (RHIC) polarized proton beam. We present measurements of AN and ANN at center-of-mass energies ?(s)=6.8 and 13.7 GeV. These spin-dependent observables are sensitive to the poorly known hadronic spin-dependent amplitudes. Comparing AN at different energies, a ?(s) dependence of the hadronic single spin-flip amplitude is suggested. A hadronic double spin-flip amplitude from the ANN data is consistent with zero within a 2-? level. We also present ??T, estimated from the measured ANN data. The results for ??T are consistent with zero. Our results provide significant constraints toward a ...
In this paper we present results of our investigation into the relationship between urban microclimate and the local density of tree cover as measured in Sacramento, California. These results were obtained through analysis of data collected in a two-month long monitoring program with automatic weather stations installed at 15 residential locations throughout the city. Measured wind speeds showed a highly negative correlation with respect to tree cover. Daily peak air temperatures showed significant variation often differing from site to site by 2 to 4{degrees}C ({approx}3.5 to 7{degrees}F). A complex interaction between several competing factors is discussed leading to the conclusion that additional tree cover may actually increase urban air temperatures on synoptically cool days. It is suggested that this does not have a significant adverse affect in terms of overall summer urban cooling load. This is ...
Implementation of the Government Performance and Results Act of 1993 (GPRA) has provided a unique challenge for Federal Agencies, such as the Department of Energy (DOE) Office of Waste Management (OWM). While performance measurement, as required by GPRA, is new to Federal Agencies, private industry has applied it at all organizational levels to better manage their operations for some time. There has been significant discussion about how the private sector uses performance measures, but there have been very few empirical studies systematically examining their use. To gather information on comparable private industry practices, waste management industry firms were surveyed through questionnaires and follow-on interviews. Questionnaires were sent to 75 waste management firms throughout the United States and Canada. Twenty-four percent of the firms responded to the questionnaire and participated in the follow-on interviews. The ...
With an objective to detect faults estimated to exist along the Shigesumi valley in the Kamioka mine, discussions were given by using electromagnetic survey, which uses the Turam measurement arrangement based on the TEM method, and three-dimensional model calculations. The Turam measurement arrangement, which installs transmission loop fixedly, is used to identify nature and distribution of electrically conductive objects upon noticing abnormal portions in magnetic fields in the measurement data. In the model calculation, the plate model calculation method and the FDTD method were used, and so was the calculation code TEM3DL. The result revealed that strong topographical influence is seen from steep V-shaped valley existing along the traverse line in the measurement data, but an abnormal resistivity band accompanying remarkable distortion in the curve was detected. According to the ...
Results related to the experimental measurement campaign to characterize atmospheric aerosol carried out near Avigliana (Turin) from 18 to 22 October 1994 are presented in this paper. In the frame of the project aimed at evaluating the impact of the mountain motor way A-32 Rivoli-Bardonecchia-Frejus on the Susa Valley environment and on man the present measurement campaign is the second, and last, one envisaged in the project. The sampling place is in the initial part of the Susa Valley while previous measurements were carried out in the high part of it. Mass mean concentrations result greater in the low than in the high part of the valley approximately by a factor of 3. It is not possible to prove a difference between the 3 sampling positions transversely placed from 20 to 80 m. in comparison with the motor way axis. Whereas mass mean concentrations dropped substantially due to ...
In this study, adjoint sensitivity theory is developed for equations of two-dimensional steady-state flow in a confined aquifer. Both the primary flow equation and the adjoint sensitivity equation are solved using the Galerkin finite element method. The developed computer code is used to investigate the regional flow parameters of the Leadville Formation of the Paradox Basin in Utah and the Wolcamp carbonate/sandstone aquifer of the Palo Duro Basin in the Texas Panhandle. Two performance measures are evaluated, local heads and velocity in the vicinity of potential high-level nuclear waste repositories. The results illustrate the sensitivity of calculated local heads to the boundary conditions. Local velocity-related performance measures are more sensitive to hydraulic conductivities. The uncertainty in the performance measure is a function of the parameter sensitivity, parameter variance and the ...
A new emissivity measurement device with inductive sample heating is described. The disc shaped samples can be measured between 800 C and 2000 C in vacuum or in each available gas atmosphere. Two kinds of surface temperature measurement methods are described, one by measuring in a blackbody hole and one by measuring at the surface without additional measures to correct emissivity. Total normal and spectral emissivity at wavelengths between 0,5 {mu}m and 8,3 {mu}m of various high temperature materials like platinum and Pt-Rh-alloys, siliconcarbide and molybdenum disilicide have been measured. From the investigated materials a few have been selected as reference samples for comparative emissivity measurements fullfilling the requirement of stability on air up to 400 C to 1000 C in order to ensure reproducibility of the ...
Several signatures of new physics accessible at the LHC either suffer from top-quark production as a significant background or contain top quarks themselves. In this talk, we present results on top quark physics obtained from the first LHC data collected by the CMS experiment.They include measurements of the top pair production cross section in various channels and their combination, measurements of the top quark mass, the single top cross section, a search for new particles decaying into top pairs, and a first look at the charge asymmetry.
A new approach for the selection of best PSS locations in multimachine power systems is proposed in this paper. Study shows that the right-eigenvector measures the activity of state variables and the left-eigenvector measures the control effect of control signals. Based on the right and left eigenvector the concept of sensitivity of PSS effect (SPE) is presented and used to identify the best PSS locations. The proposed method is used to identify the best PSS location in a 13-machine system to increase the damping of an interarea mode. The time-domain simulation results confirm that the prediction of best PSS location by SPE method is correct and accurate.
The HARP experiment at CERN is performing extensive measurements of hadron production cross sections and secondary particle yields, in the momentum range 1.5-15 GeV/c, over the full solid angle and using a large set of cryogenic and solid targets. First measurements of hadron production cross-sections in the forward region are reported using an aluminium target 5% of an interaction length thick and a proton beam of 12.9 GeV/c. A preliminary analysis in the large angle region of elastic scattering events produced with the cryogenic hydrogen target at 3 GeV/c beam momentum is also presented.
We have measured the neutron capture and fission cross section of "2"3"3U at the neutron time-of-flight facility n-TOF at CERN in the energy range from 1 eV to 1 MeV with high accuracy by using a high performance 4#pi# BaF_2 Total Absorption Calorimeter (TAC) as a detection device. The method, based on the shape analysis of the TAC energy response, allowing to disentangle between #gamma#'s originating from fission and capture will be presented as well as the first very preliminary results. (authors)
Extensive experimental and analytical investigations of fluid flow and heat transfer in gas-cooled rod bundles have been carried out. Different bundle geometries with partially or fully roughened rod surfaces were tested in a carbon dioxide loop. An advanced and comprehensive measuring control and instrumentation are important design features of this experiment. Comprehensive thermal hydraulic subchannel analysis computer codes have been developed in order to assist fuel element design calculation for gas-cooled reactors. The experiments, codes and their verification procedure are described and the results of comparisons between measured and calculated pressure and temperature distributions are given. (orig.).
The Monte Carlo ray-tracing method is applied and coupled with optical properties to predict the radiation performance of solar concentrator/cavity receiver systems. Several different cavity geometries are compared on the radiation performance. A flux density distribution measurement system for dish parabolic concentrators is developed. The contours of the flux distribution for target placements at different distances from the dish vertex of a solar concentrator are taken by using an indirect method with a Lambert and a charge coupled device (CCD) camera. Further, the measured flux distributions are compared with a Monte Carlo-predicted distribution. The results can be a valuable reference for the design and assemblage of the solar collector system.
Neutron spectra measured in the FFTF In-Reactor Thimble (IRT) by proton recoil proportional counters, proton recoil emulsions, and passive dosimeters have been evaluated and compared with each other and with three-dimensionl diffusion theory calculated spectra for the purpose of validating the passive dosimeter spectrum adjustment technique. The least squares data adjustment code, FERRET, was used to combine measured reaction rates, calculated spectra, and dosimeter cross sections, resulting in adjusted spectra and cross sections with uncertainties and correlations that properly account for uncertainties and correlations on the input parameters.
It may be stated that for the calculation of the heat transfer coefficients for natural convection cooling of large-diameter finned surfaces it is necessary to take in consideration the effects of the fin length, fin material and of the azimuthal angle around the cylinder. The present results replace earlier less accurate correlations gained from the same measurements. The new, better correlation was elaborated with the aid of the improved method of evaluation of multiple parameters of a measurement matrix of multiple dimension (one dimension for each parameter), rendering the sum of the squares error a minimum at the same time for the complete matrix. 5 references.
This review of methods and designs of transducers for nondestructive determination of the magnitude and nature of the anisotropy of magnetic properties (permeability, induction, coercive force, energy loss due to magnetization reversal) in local portions of ferromagnetic sheet and, in some cases, in individual parts of products. The need to measure the anisotropy is considered for two angles: for the case when the anisotropy is due to the crystallographic texture and determines the main operating characteristics of widely used sheet such as electrical steel and automobile body sheet, and for crystallographically isotropic materials, in which the anisotropy of magnetic properties as a result of mechanical stresses is a measure for determining the internal stresses.
The (p,n) cross section on "8"8Sr was measured for proton energies between 5.75 and 11 MeV. Overall resolution was sufficient to separate the "8"8Y ground state (J/sup #pi#/ = 4"-), the first excited state (J/sup #pi#/ = 5"-) at 0.232 MeV, and the second excited state (J/sup #pi#/ = 1"+) at 0.393 MeV. A Legendre polynomial fit was made to the angular distributions and the resulting integrated cross sections are shown. 1 figure.
We have measured the K-shell ionization probability across the 6.06-MeV resonance in /sup 88/Sr(p,p/sub 0/) where the resonance width is large compared to the energy transferred to the electron. The results are found to agree quantitatively with the theory developed by Blair and Anholt. The effect of the time delay on the ionization probability, introduced by the nuclear scattering at the resonance energy, is discussed.
Several recent experiments on micro- (or nano-) structured samples of ferromagnetic materials are introduced. Magnetization reversal phenomena are investigated on submicron wire samples of trilayer structure using the giant magnetoresistance effect. Domain wall movements are sensitively monitored by resistivity measurements and the velocity of propagation is determined. The contribution of domain wall to the resistivity is argued from the results on artificially designed samples of a spring-magnet system. In circular dots of permalloy, the existence of vortex magnetization is confirmed and the reversal of the vortex core magnetization is studied from magnetic force microscopy measurements. (author)
Argon ion laser induced fluorescence measurements were carried out in a multipolar filament discharge with a broadband diode laser centered on 668 nm, which stimulated a transition from the metastable state in Ar(II) 3d4F7/2 to 4p4D05/2. The intensity of the induced fluorescence at 442 nm was maximized by the optimization of the discharge parameters and the laser power. From the recovery of the background fluorescence after the laser was turned off, the ion diffusion coefficient was deduced and compared with the result inferred from the experiments of ion acoustic wave (IAW) damping.
The ongoing upgrade of the Los Alamos Free-Electron Laser (FEL) Facility involves the addition of a photoelectric injector (PEI) and acceleration capability to about 40 MeV. The electron-beam and high-speed diagnostics provide key measurements of charge, beam position and profile, divergence emittance, energy (centroid, spread, slew, and extraction efficiency), micropulse duration, and phase stability. Preliminary results on the facility include optical transition radiation interferometer measurements of divergence (1 to 2 mrad), FEL extraction efficiency (0.6 {plus minus} 0.2%), and drive laser phase stability (< 2 ps (rms)). 10 refs.
The ongoing upgrade of the Los Alamos Free-Electron Laser (FEL) Facility involves the addition of a photoelectric injector (PEI) and acceleration capability to about 40 MeV. The electron-beam and high-speed diagnostics provide key measurements of charge, beam position and profile, divergence emittance, energy (centroid, spread, slew, and extraction efficiency), micropulse duration, and phase stability. Preliminary results on the facility include optical transition radiation interferometer measurements of divergence (1 to 2 mrad), FEL extraction efficiency (0.6 {plus_minus} 0.2%), and drive laser phase stability (< 2 ps [rms]). 10 refs.
The branching ratio of J/psi-->K_S K_L is measured with improved precision to be B(J/psi-->K_S K_L) = (1.82\\pm 0.04\\pm 0.13)\\times 10^{-4}. using J/psi data collected with the Beijing Spectrometer (BESII) at the Beijing Electron-Positron Collider. This result is used to test the perturbative QCD ``12%'' rule between psi(2S) and J/psi decays and to investigate the relative phase between the three-gluon and one-photon annihilation amplitudes in J/psi decays.
This report covers the gamma detectors, measurement instrumentation, and testing results of a system developed at Los Alamos National Laboratory. This system monitors the process liquid waste streams at the Plutonium Facility (TA-55) for the presence of radioactive contamination. The detectors are at various points on the acid, caustic, and industrial waste lines. Two of the detectors are on the sanitary sewer lines from the facility. A custom interface unit associated with these two detectors furnishes the facility operation center with a notification of the detection of material. All of the detectors furnish measurement information to a central computer system for storage and trending.
Absolute fission rate measurements using modified National Bureau of Standards fission chambers were performed in the Fast Flux Test Facility at two core locations for isotopic deposits of {sup 232}Th, {sup 233}U, {sup 235}U, {sup 238}U, {sup 237}Np, {sup 239}Pu, {sup 240}Pu, and {sup 241}Pu. Monitor chamber results at a third location were analyzed to support other experiments involving passive dosimeter fission rate determinations.
Absolute fission rate measurements using modified National Bureau of Standards fission chambers were performed in the Fast Flux Test Facility at two core locations for isotopic deposits of {sup 232}Th, {sup 233}U, {sup 235}U, {sup 238}U, {sup 237}Np, {sup 239}Pu, {sup 240}Pu, and {sup 241}Pu. Monitor chamber results at a third location were analyzed to support other experiments involving passive dosimeter fission rate determinations.
We show that a stationary IDp process (i.e., an infinitely divisible stationary process without Gaussian part) can be written as the independent sum of four stationary IDp processes, each of them belonging to a different class characterized by its L\\'{e}vy measure. The ergodic properties of each class are, respectively, nonergodicity, weak mixing, mixing of all order and Bernoullicity. To obtain these results, we use the representation of an IDp process as an integral with respect to a Poisson measure, which, more generally, has led us to study basic ergodic properties of these objects.
Average emittance data for ion beams extracted from cesium-sputter negative ion sources equipped with spherical, ellipsoidal, and cylindrical geometry cesium-surface ionizers are presented. The attributes of the respective source geometries are described in terms of their cesium ion optical properties. The results of recent measurement of the emittances of momentum-analyzed beams extracted from the ellipsoidal geometry source are also presented. These measurements indicate the presence of a species-dependent effect. The effect is believed to be attributable to differences in the energy spreads of the respective negative ion beams introduced by the sputter generation process.
Average emittance data for ion beams extracted from cesium-sputter negative ion sources equipped with spherical, ellipsoidal, and cylindrical geometry cesium-surface ionizers are presented. The attributes of the respective source geometries are described in terms of their cesium ion optical properties. The results of recent measurement of the emittances of momentum-analyzed beams extracted from the ellipsoidal geometry source are also presented. These measurements indicate the presence of a species-dependent effect. The effect is believed to be attributable to differences in the energy spreads of the respective negative ion beams introduced by the sputter generation process. 11 refs., 8 figs.
Here I provide a brief overview of recent experimental gas-phase measurements using the Selected-Ion Flow Tube or SIFT technique at 294#+-#2 K with helium buffer gas at 0.35 Torr for reactions which remove electrons from the C_6_0 molecule or donate electrons to singly and multiply-charged C_6_0 cations. The results of these measurements have provided new insight into physicochemical aspects of electron transfer and have revealed the occurrence of unprecedented electron transfer reactions at thermal energies. (author).
The purpose of the present research is to find a suitable technique to measure trace amounts of uranium and thorium and to determine the surface #alpha#-flux in silicon compound (SiO) used for fabrication of integrated circuit packaging materials. Among several commonly-used detecting techniques, it was found that neutron activation analysis (NAA) was most promising. The results from NAA show a large difference in uranium and thorium concentrations when cadmium and boron carbide shields are used, whereas #alpha#-flux measurements show a low #alpha#-activity, which corresponds to the trace amounts of uranium and thorium expected to be present in these materials. (author) 13 refs.; 6 figs.
In the 1993 running cycle of the Stanford Linear Collider electron spin polarization measurements with a Moller polarimeter at the end of the linac and a Compton polarimeter near the interaction point (IP) indicated a relative polarization loss of up to 20% across the arc. We present calculations of the depolarizing effects where variations in energy, energy spread and transverse emittance as well as changes in orbit and initial spin orientation are taken into account. We compare our results with measurements and conclude that, in standard operating conditions, the relative polarization loss is only 3+/-2%.
Daya Bay Neutrino Experiment is dedicated to measuring the last unobserved neutrino mixing angle theta_13. The predicted precision on sin^2(2theta_13) is 0.01 at 90% confidence level. This document briefly reviews the measurement method and detector construction status. The first two anti-neutrino detectors' dry run result is also discussed. The Daya Bay near hall data taking is expected to commence in the summer of 2011 and the data taking of all of the three halls in the summer of 2012.
Ion-photon and ion-Auger-electron coincidence measurements have been performed to study the impact parameter dependence of Xe M-shell excitation in 1.05 MeV Xe/sup 3 +/-Xe collisions. The experimental results are found to be consistent with the prediction of the molecular orbital model of atomic collisions. The average fluorescence yield for the Xe M shell is found to be strongly dependent on the impact parameter. This is ascribed to the production of highly charged Xe ions in close collisions.
A brief review is presented of transport in the boundary region of magnetized plasmas by blob-like filaments. Such structures have enhanced levels of particles and heat, are elongated along the magnetic field lines and are localized in the drift plane across the field. The motion of an isolated blob structure is described in some detail and the contribution of such filaments to turbulence-driven transport are discussed. Results are presented from numerical simulations and probe measurements in tokamak plasmas. An interpretation is given of the measured dependence of particle density and transport on experimental control parameters in the scrape-off layer. (author)
A method of using gamma radiation to determine the density and phase distribution in two-phase flows in pipes is described. Three collimated beams of radiation that pass through a pipe cross-section at different radial positions are used. A theory and computer program used to relate the measured attenuation of these beams to a three-parameter model of the phase distribution and to the average density and void fraction are discussed. Data obtained during both static and dynamic verification experiments using Lucite inserts are presented, as well as the results of several tests done in high pressure, steam-water flows.
Safe and economical operations with fissile materials require knowledge of the subcriticality of configurations that arise in material processing, storage, and transportation. Data from critical experiments have been a principal source of information with which to establish safety margins. However, the lower cost and the expediency of performing confirmatory subcritical measurements on the process floor or in the storage vault resulted in much of the early criticality safety guidance being based on subcritical in situ experiments.
Activity concentrations of some anthropogenic radionuclides (90Sr, 137Cs, 238Pu, 239+240Pu and 241Am) have been measured in the surface of marine sediments along the Saudi coast of the Arabian (Persian) Gulf. The samples were collected at different locations and water depths. The spatial distribution of the concentrations of the measured radionuclides showed a heterogeneous pattern and is independent of location or water depth. The obtained results are discussed and some conclusions are drawn.
The feasibility of the anodic protection of titanium evaporators in Al[sub 2](SO[sub 4])[sub 3] solution was studied by the measurement of polarization curves, weight loss, solubility of passive film and AC impedance. The protection parameters and efficiency were determined. In addition, the practical technology of anodic protection was studied by screening reference electrodes and auxiliary cathodes. Throwing power was also measured. Four rows of tube-type evaporators of titanium have been anodically protected in situ. Field tests lasting more than one year shows satisfactory results. (orig.)
Localized corrosion has a stochastic character by nature. This character leads to an observed random behavior: fluctuations of the free potential, fluctuations of the current when a constant potential is maintained. This random signal, which is similar to an electric noise, can be analyzed either in the time domain by counting the events or in the frequency domain by measuring the power spectral density of the electrochemical noise. The experimental techniques developed for investigating the localized corrosion on the probabilistic point of view, i.e., statistical counting and power spectral density measurements, are discussed. Then the experimental results reported in the literature are reviewed in order to see what kind of parameters are accessible and how they can be related to the localized corrosion processes.
A new technique for radon measurement in the natural environment was investigated. It is based on the use of activated charcoal and a track-etch detector. The charcoal acts as a radon collector from the air and the track-etch detector as a recorder of the alpha particles emitted by radon and its decay products. Our preliminary results show that the response of the new dosimeter to radon, using Deodorant activated charcoal (TOK, Yugoslavia) and a CR-39 track-etch detector, is 1.4 tracks cm{sup -2}/Bqm{sup -3}d, which is about eight times higher than that obtained with a standard track-etch dosimeter. (author).
The following paper is focused on the numerical modelling of the transient radon diffusion through radon-proof membranes during the measurement of their radon diffusion coefficient. The major aim of such numerical modelling is to increase the accuracy of radon diffusion coefficients derived from the measured data sets. The developed complex ''transient'' numerical model is able to calculate the radon diffusion coefficient with sufficient accuracy from almost any data set - even from a short-time measurement with a non-linear course of results. This numerical model can also be used for various analyses of transient radon transfer processes (e.g. for the calculation of radon distribution curves within the membrane). The following paper presents governing equations for the simulation model, together with a brief description of algorithms incorporated in the newly ...
Design of the Alcator C-Mod Thomson scattering (TS) diagnostic is discussed and the results of the measurements are presented. The TS system has six spatial channels with observation volumes evenly distributed between the midplane and the edge of the plasma. Each channel is capable of measuring the electron density in the range N{sub e}=5{times}10{sup 19}{endash}5{times}10{sup 21} m{sup {minus}3} and temperature from T{sub e}=200 eV to 10 keV. A 30 Hz, 1.5 J per pulse Nd-YAG laser is employed allowing the measurements of evolution of T{sub e} and N{sub e} profiles during plasma shot. A laser beam position control and feedback system provides for the beam alignment stability and reliable electron density measurements. Examples of the core density and temperature profiles measured at different stages of the plasma evolution are discussed. {copyright} {ital 1999 ...
The NPDGamma Experiment measures the parity-violating correlation A{sub {Gamma}Y} between neutron spin and photon momentum in the reaction {rvec n} + p {yields} d + {gamma}. Knowledge of A{sub {Gamma}Y} and other parity-violating observables in few-body nuclear systems will provide constraints for a parameterized description of {Delta}S = 0 parity-violating phenomena free from complications of nuclear structure. The NPDGamma experiment uses a polarized cold pulsed neutron beam, a liquid parahydrogen target, and a cylindrical array of 48 CsI(Tl) scintillation detectors operated in current mode to search for the asymmetry. NPDGamma recently completed the first phase of the program to measure A{sub {Gamma}Y} at the Los Alamos Neutron Science Center with the preliminary result A{sub {Gamma}Y} = (-1.2 {+-} 2.1(stat.) {+-} 0.1(sys.)) x 10{sup -7}, reproducing the previous upper limit from a measurement at a ...
The paper reported on an experiment on measurement of concentration of highly concentrated coal slurry using microwaves carried out at Miike coal preparation works. The purpose of the experiment was to investigate applicability of microwave moisture content measurement of slurry of a mixture of coal and coal particles and to use it to the control of process such as coal preparation and processing. In the experiment, a method for measuring the slurry concentration was adopted in which the container filled with highly concentrated coal slurry was irradiated with microwaves and the damping of strength of the penetrating microwaves was detected. As a result of the experiment, it was found out that there was a big correlation between the capacitive concentration of slurry and the damping ratio of microwaves. When irradiating slurry with microwaves of 1GHz frequency, a big correlation between the ...
Wireless sensor networks can revolutionize soil ecology by providing measurements at temporal and spatial granularities previously impossible. This paper presents a soil monitoring system we developed and deployed at an urban forest in Baltimore as a first step towards realizing this vision. Motes in this network measure and save soil moisture and temperature in situ every minute. Raw measurements are periodically retrieved by a sensor gateway and stored in a central database where calibrated versions are derived and stored. The measurement database is published through Web Services interfaces. In addition, analysis tools let scientists analyze current and historical data and help manage the sensor network. The article describes the system design, what we learned from the deployment, and initial results obtained from the sensors. The system measures soil factors ...
The purpose of this document is to provide a framework for developing protective strategies in the longer term following an accidental release of radionuclides to the offsite environment. This advice covers all forms and scales of accidental release, including releases from nuclear sites and reactors, weapons accidents, and damaged industrial or medical sealed sources. The countermeasures considered are those intended to protect the public from external irradiation from radionuclides deposited in the environment, from the inhalation of resuspended radionuclides, and from inadvertent ingestion of radionuclides resulting from contact with contaminated surfaces. The Board terms these recovery countermeasures. They can be broadly grouped as either decontamination measures (ie measures that deal directly with the radionuclides, whether by removing them, shielding them or physically or chemically bonding them) or as restricted ...
In October last year the first intercomparison of measurements of the soil radon concentrations between various laboratories in Slovakia was realised. The organisation of this intercomparison was conducted by the Slovak Legal Metrology in Banska Bystrica together with the Slovak National Accreditation Service in Bratislava (SNAS). The scientific guarantee of the exercise was the State metrological Centre for radon quantities, which is working at the Research base of Slovak Medical University in Bratislava. The main objective of the intercomparison was to verify the correctness of the methods for the soil radon measurements of the authorised laboratories for radon volume activities in soil air. The intercomparison (signed as SLM ILC 3/03) was performed as a 'circular' metrology comparison, in accordance with a methodical directive MSA 0117-98, published by SNAS. Six laboratories were participating on the intercomparison and there have been two ...
The influence of the velocity profile at the inlet boundary on the simulation of air velocity distribution inside an electrostatic precipitator is presented in this study. Measurements and simulations were performed in a duct and an electrostatic precipitator (ESP). A four-hole cobra probe was used for the measurement of velocity distribution. The flow simulation was performed by using the computational fluid dynamics (CFD) code FLUENT. Numerical calculations for the air flow were carried out by solving the Reynolds-averaged Navier-Stokes equations coupled with the realizable k-{epsilon} turbulence model equations. Simulations were performed with two different velocity profiles at the inlet boundary - one with a uniform (ideal) velocity profile and the other with a non-uniform (real) velocity profile to demonstrate the effect of velocity inlet boundary condition on the flow simulation results inside an ESP. The real ...
This section contains the detailed measured impact results and market segment data for each DSM case examined for this building type. A complete index of all base and measure cases defined for this building type is shown first. This index represents an expansion of the base and measure matrix presented in Table 1 (residential) or Table 2 (commercial) for the applicable sector. Following this index, a summary report sheet is provided for each DSM measure case in the order shown in the index. The summary report sheet contains a host of information and selected graphs which define and depict the measure impacts and outline the market segment data assumptions utilized for each case in the DBEDT DSM Forecasting models. The variables and figures included in the summary report sheet are described. Numerous tables and figures are included.
This section contains the detailed measured impact results and market segment data for each DSM case examined for this building type. A complete index of all base and measure cases defined for this building type is shown first. This index represents an expansion of the base and measure matrix presented in Table 1 (residential) or Table 2 (commercial) for the applicable sector. Following this index, a summary report sheet is provided for each DSM measure case in the order shown in the index. The summary report sheet contains a host of information and selected graphs which define and depict the measure impacts and outline the market segment data assumptions utilized for each case in the DBEDT DSM Forecasting models. The variables and figures included in the summary report sheet are described. Numerous tables and figures are included.
Type 440C stainless steel is a high-C, high-Cr martensitic steel used in applications requiring high hardness and wear resistance in combination with moderate corrosion resistance. Typical applications include precision aerospace bearings and critical components in computer disk drives. The properties of passive films formed on 440C steel were investigated using advanced electrochemical techniques with a view to establishing a method to measure film stability directly in the passivation baths. Electrochemical measurements were sensitive to the passive film properties and were able to quantify the effect of cooling rate on passive film stability. The techniques used included linear polarization, AC impedance, small amplitude cyclic voltammetry, and coulostatic transient measurements. These provided results that exhibited excellent agreement with the AC impedance technique providing the most information ...
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement ...
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement ...
Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were ...
Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel ...
We directly measure the evolution of the intergalactic Lyman-alpha effective optical depth, tau_eff, over the redshift range 2 is <1% at z=2, 4% at z=3, and 12% at z=4. Previous measurements of tau_eff at 3results in the literature, finding that this contribution is ~6-9% at z=3 and decreases monotonically with redshift. The high precision of our measurement, attaining 3% in redshift bins of width Delta z=0.2 aro und z=3, indicates significant departures from the best-fit power-law redshift evolution (tau_eff=0.0018(1+z)^3.92, when metals are left in), particularly near z=3.2. The observed downward departure ...
This research aims at elucidating thermal hydraulic phenomena by carrying out their visualization and measurement which are difficult by conventional method, utilizing the excellent properties of real time neutron radiography and showing the usefulness of neutron radiography. The experiments were carried out on the visualization and measurement of liquid metal flow and mixed phase flow and the visualization and diagnosis of mixed phase flow equipment. As the achievement in this fiscal year, the image-processing method for visualizing quantitatively the distribution of void fraction in gas-liquid two-phase flow has been devised, therefore, its method and results are reported. For the analysis of multi-dimensional two-phase flow, in order to prepare the model and determine the constitution equation, the data on the multi-dimensional distribution of void fraction are required. Void fraction is defined. The method of image ...
The results of experimental measurements and theoretical simulations of circular dichroism in the angular distribution (CDAD) of photoemission from atomic core levels of each of the enantiomers of a chiral molecule, alanine, adsorbed on Cu(1 1 0) are presented. Measurements in, and out of, substrate mirror planes allow one to distinguish the CDAD due to the chirality of the sample from that due to a chiral experimental geometry. For these studies of oriented chiral molecules, the CDAD is seen not only in photoemission from the molecular chiral centre, but also from other atoms which have chiral geometries as a result of the adsorption. The magnitude of the CDAD due to the sample chirality differs for different adsorption phases of alanine, and for different emission angles and energies, but is generally small compared with CDAD out of the substrate mirror planes which is largely unrelated to the ...
This paper uses a choice experiment to evaluate the consumers' willingness to pay for energy-saving measures in Switzerland's residential buildings. These measures include air renewal (ventilation) systems and insulation of windows and facades. Two groups of respondents consisting respectively of 163 apartment tenants and 142 house owners were asked to choose between their housing status quo and each one of the several hypothetical situations with different attributes and prices. The estimation method is based on a fixed-effects logit model. The results suggest that the benefits of the energy-saving attributes are significantly valued by the consumers. These benefits include both individual energy savings and environmental benefits as well as comfort benefits namely, thermal comfort, air quality and noise protection. (author)
The refrigerant two-phase flows in a capillary tube and a distributor used in a compression-type refrigerator were visualized by real-time neutron radiography. The thermal neutron radiography system of JRR-3M at the Japan Atomic Energy Research Institute was used. In the visualization experiments of the two-phase flow in the capillary tube of 2 mm I.D., a cooled CCD camera was used, and the axial one-dimensional distributions of void fraction were measured. For the distributor, a high sensitivity video camera with a silicone intensified target tube was used. From the visualized images, the refrigerant behaviors in the distributor were clearly shown, and the liquid fraction in each tube was measured. As a result, it was shown that the refrigerant behaviors in the distributor effected the distributing performance of the refrigerant flow.
Contamination of certain areas of Europe with radiocaesium from the Chernobyl accident led to a higher {sup 137}Cs accumulation (i.e. 300-600 Bq kg{sup -1}) in grain and to potential post-accident contamination of broiler chickens. In future, such contamination may require a simple determination of the {sup 137}Cs activity concentration in broiler chicken meat which would lead to measures for preventing the recommended limits of radionuclide contamination of the meat for human consumption from being exceeded. This paper describes the development of a rapid method for the in vivo monitoring of the broiler chicken using a lead-shielded sodium iodide detector. The method enables simply fixed live chicken to be monitored, the results showing a good correlation (R{sup 2}=0.98) with measurements of meat from chicken previously monitored in vivo prior to slaughter.
This series of measurements with a mixed Pu-U nitrate solution (280 g Pu/liter, 180 g U/liter) in a 35.54-cm-diam cylindrical tank provides a wide variety of experimental data for subcritical configurations that can be used to verify calculational methods and nuclear data. The Pu contained 7.85 wt% {sup 240}Pu and the uranium was natural uranium. The measurements performed were: inverse count rate, prompt neutron decay constants, inverse kinetics, and frequency analysis by the {sup 252}Cf source driven method. These data are presented in sufficient detail that the results of the experiments can be calculated directly. For purposes of extrapolating to the delayed critical height the ratio of spectral densities was linear with height and thus provided the best estimate of critical height.
In patients subjected to bone marrow transplantation the aggressive measures necessarily preceding this treatment lead to drastic metabolic changes which, in turn, are a cause of marked disturbances of homeostasis. The general preparatory measures in the form of cytoreduction by cytostatic drugs are broadened for leukaemic patients to include wholebody irradiation. During the study described here investigations were carried out into the resulting strain on the metabolism. One of the most essential changes observed in those patients was a nitrogen loss of up to approx. 20 g/day that occurred during the immunosuppressive phase. This was accompanied by markedly pronounced variations in fluid elimination, which partly were of an iatrogenic nature. An immediate and sufficient substitution of amino acids in connection with complete parenteral nutrition rapidly acted to compensate for the nitrogen losses, even though these could ...
The report considers experimental and theoretical works on studying the energy spectra of prompt neutrons emitted in spontaneous fission and neutron induced fission of Minor Actinides. It is noted that neutron spectra investigations were done for only a small number of such nuclei, most measurements, except those of Cf-252, having been carried out long ago by obsolete methods and imperfectapparatus. The works have no detailed description of experiments, analysis of errors, detailed numerical information about results of experiments. A conclusion is made that the available data do not come up to modern requirements. It is necessary to make new measurements of fission prompt neutron spectra of transuranium nuclides important for the objectives of working out a conception of minor actinides transmutation by means of special reactors. (author).
Abstract Suspension of solids in stirred reactor is widely used for catalytic reactions, dissolution, etc. Quality of solid suspension is an important parameter required for the reliable design, optimum performance, and scale up of the system. Quality of suspension depends on local characteristics of solid velocity and hold up profiles. The present work was focused on investigating quality of solid suspension using ultrasound velocity profiler (UVP) measurements and CFD simulations. The slip velocity measurements carried out with UVP were used to evaluate different drag correlations used in CFD simulations. Results discussed in this work would be useful for extending the applications of CFD models for simulating large stirred slurry reactors.
A novel envelope-type radon monitor has been used for short-term (as little as 1 week) radon concentration measurements in a workplace environment. The commercially available LR-115 type II damage track detector was used in this study and the chemically etched sheets were spark counted. The measurements were made over a period of 1 year in a workplace consisting of three adjacent rooms situated in the lower ground level of multistorey office building in Rome, Italy. The variations of the radon concentration are from [approx] 20 to [approx] 300 Bq m[sup -3] with averages of 130,81 and 73 Bq m[sup -3] for the three different rooms resulting in annual doses of [approx] 3.8, [approx] 2.4 and [approx] 2.2 mSv, respectively. (author) 2 figs., 9 refs.
The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm{sup -3}, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.
The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm-3, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.
Two neutrino mixing angles have been measured, and much of the neutrino community is turning its attention to the unmeasured mixing angle, $\\quq$, whose best limit comes from the reactor neutrino experiment CHOOZ.\\cite{bib:chooz} New two detector reactor neutrino experiments are being planned, along with more ambitious accelerator experiments, to measure or further limit $\\quq$. Here I will overview how to measure $\\quq$ using reactor neutrinos, mention some experiments that were considered and are not going forward, and review the current status of four projects: Double Chooz in France, Daya Bay in China, RENO in South Korea and Angra in Brazil. Finally I will mention how the neutrino observer can gauge progress in these projects two years from now as we approach the times corresponding to early estimates for new results.
Radon ({sup 222}Rn) is a naturally occurring radioactive gas and can be used as a tracer in hydrogeologic studies. Radon concentration measurements have been achieved in ground-air and in groundwater by means of nuclear track detectors to estimate long-term variations. Continuous measurements have been conducted using an electronic automatic probe, to evaluate short-term variations. The results obtained from bore-holes show a good correlation between the aquifer`s structural characteristics and the radon concentrations. The continuous measurements specify rainfall influence. (author). 10 refs., 7 figs., 2 tabs.
Rossi X-ray Timing Explorer (RXTE) observations of the bright supernova remnant Cas A have revealed a hard power law component above 10 keV in addition to two thermal components inferred from ASCA measurements of the many line centroids from low-Z elements. The power law can be shown to be consistent with synchrotron emission from radio to hard x-rays by electrons of up to 4 x 10"1"3 eV. Measurement of the 1157 keV line by CGRO from "4"4Sc in the chain of decay of "4"4Ti predicts that the two "4"4Ti lines at 68 and 78 keV should appear at the CGRO intensity. RXTE has placed upper limits on such lines that are marginally consistent with the CGRO measurement. Implications of these results on sites for cosmic ray acceleration and nucleosynthesis are discussed.
We have performed polarized neutron diffraction measurements on the intermediate valence compound CePd{sub 3} using the D3 spectrometer at the ILL. The results show that at low temperatures, 1.7 K, as well as at 100 K, the field-induced magnetic amplitudes measured in a field of 4.6 T could be interpreted in terms of two contributions: a 4f-type contribution with a Ce{sup 3+} form factor, and an extra delocalized contribution (relatively narrow in q-extent). In particular, we find that the values of the 4f moment deduced from the extrapolation of the neutron data to Q=0 are systematically lower than the values deduced from bulk magnetization measurements performed on the same sample. This difference can be ascribed to a possible positive polarization of the conduction band which is similar at both temperatures.
The wind turbines with a flanged-diffuser shroud-so called ?wind lens turbine??-are developed as one of high performance wind turbines by Ohya et al. In order to investigate the flow characteristics and flow acceleration, the paper presents the flow velocity measurements of a long-type and a compact-type wind turbines with a flanged-diffuser shroud by particle image velocimetry. In the case of the long type wind turbine, the velocity vectors of the inner flow field of the diffuser for turbine blades rotating and no blades rotating are presented at Reynolds number, 0.9?105. Furthermore the flow fields between with and without rotating are compared. Through the PIV measurementresults, one can realize that the turbine blades rotating affects as suppress the disturbance and the flow separatio...
Long term indoor radon gas measurements using a passive monitor are now being conducted in the basement HVAC machine rooms of about fifty commercial buildings, which are built in the Tokyo and Nagoya metropolitan area. Ventilation rates are also measured during the monitoring period. The earliest results show that the highest concentration was about twice of the EPA Standards and was obtained at Nagoya in autumn and no clear seasonal change was seen in radon concentration so far, and that the correlation between radon concentration and inverse number of ventilation rate was positive but not high. (orig.). (2 refs., 4 figs., 2 tabs.).
The authors have made new and improved measurements of the neutron capture and total cross sections of {sup 88}Sr at the Oak Ridge Electron Linear Accelerator (ORELA). Improvements over previous measurements include a wider incident neutron energy range, the use of metallic rather than carbonate samples, better background subtraction, reduced sensitivity to sample-dependent backgrounds, and better pulse-height weighting functions. Because of its small cross section, the {sup 88}Sr(n,{gamma}) reaction is an important bottleneck during the s-process nucleosynthesis. Hence, an accurate determination of this rate is needed to better constrain the neutron exposure in s-process models and to more fully exploit the recently discovered isotopic anomalies in certain meteorites. They describe the experimental procedures, compare the results to previous data, and discuss their astrophysical impact.
During this reporting period the work supported by the US Department of Energy Grant No. DE-FG02-87ER40326.A005 has resulted in two publications and two papers presented at professional meetings. The neutron scattering measurement for this budget period has been completed along with scattering measurements for carbon {sup 88}Sr, {sup 40}Ar, {sup 90}Zr, {sup 208}Pb, {sup 40}Ca and {sup 28}Si. The carbon scattering yield serves to define the detector efficiencies. The silicon sample was available and is of importance in both nuclear physics and reactor physics.
The perceptual center (P-center) is fundamental to the timing of heterogeneous event sequences, including music and speech. Unfortunately, there is currently no comprehensive and reliable model of P-centers in acoustic events, so P-centers must instead be measured empirically. This study reviews existing measurement methods and evaluates two methods in detail?the rhythm adjustment method and a new method based on the phase correction response (PCR) in a synchronous tapping task. The two methods yielded consistent P-center estimates and showed no evidence of P-center context dependence. The PCR method appears promising because it is accurate and efficient and does not require explicit perceptual judgments. As a secondary result, the magnitude of the PCR is shown to vary systematically with ...
The total photoabsorption cross section on a free proton was measured at the GRAAL facility in the energy range E ? = 600?1500 MeV. The large-aperture LAGRAN?E detector and a liquid hydrogen target were used in the experiment performed with a back-scattered Compton gamma beam. To improve the accuracy, two alternative methods were employed. First, a subtraction method of using empty-target measurements allowed the cross section ? tot to be evaluated directly because of a low level of the electromagnetic background. Second, an algorithm for evaluating ? tot on the basis of summing the dominating partial cross sections was developed. Experimental results obtained for ? tot by the two methods are compared with existing data.
The measurement of level in the liquid nitrogen vessel has been carried out by the weight conversion method using weigher or by putting directly a stick in the vessel. On a large CE tank, the pressure difference was read by manometer. These methods can not be used when the vessel does not put on the weigher or the pipe for manometer is stopped. We noticed the interaction between radiation ({gamma}-ray) and substance and applied it to determine the liquid nitrogen level. The results proved it the easy method for measurement of the level in the large CE tank. Cesium 137 ({gamma}-ray energy: 662 keV) was used as the radiation source. {gamma}-ray transmission dose was determined by GM survey meter. The liquid nitrogen level could be determined by using the change of the transmission dose with amount of liquid nitrogen. (S.Y.)
Making use of a lead slowing-down spectrometer coupled to a 46 MeV electron linear accelerator and a back-to-back type double fission chamber, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40 % full width at half maximum. Each of the measuredresult has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, for which the evaluated and the experimental data were broadened by the energy resolution function of the spectrometer. (author)
Apart from presenting the marginal legal conditions the research program contains a brief description of current pollution abatement measures, representative heating systems and individually suitable pollution abatement technologies and an account of the determination of the concentration of major pollutants. The comparative evaluation of heating systems assesses their environmental effects, i.e. air pollution caused by heating systems. The determination of the costs of available heat is followed by an overall evaluation of the results obtained with special regard to the costs involved by pollution abatement measures.
One of the more extensive uses of directional drilling anywhere in the world has been in the development of the East Wilmington Oil Field in Long Beach, California. The Measurement-While-Drilling (MWD) directional system has been tested on several wells and proven to provide the required accuracy, along with many advantages over past methods, used in the field development. Accurate transmission by MWD of bottom-hole measurements to the surface is provided by mud pressure pulses generated in the drill pipe downhole and detected by a pressure transducer includes the means for detecting, recording and processing these pressure pulses, to translate the information from the pressure pulses to rig floor displays usable by the drilling crew. 2 refs.
The total bolometrically measured plasma radiation losses on the RF heating power were found. The results of measurements demonstrate a nonmonotonic dependence of radiation losses on RF power. Namely, at low RF power levels (80...170 kW) the total radiation losses raised with increasing the RF power. However, the total radiation losses decreased sharply when RF power exceeded 200 kW (down to ?20 kW at 240 kW of RF power). Simultaneously, the intensity of impurity lines fell down significantly, whereas the average electron temperature (found from ECE measurement) increased. The authors consider that screening properties of periphery plasma give reasons for above experimental facts.
We present two applications of CR-39 to estimate biological effects of heavy ion irradiation. The accurate measurement of fluence of ions using CR-39 is indispensable to calculate the action cross sections for biological effects. Ions with 6 MeV/n at the Medium Energy Beam Course, HIMAC (NIRS) were extracted to the air, and degraded with the air. DNA and living cells were irradiated by ions with various specific energies at several air columns along with the Bragg curve. DNA strand breaks and cell killing were measured and the results were converted to the action cross sections using the fluence measured with CR-39 at the irradiation positions. Another example of the application of CR-39 is to identify whether the ions with a specific energy pass through the cell or stop within the cell. (author)
In the last months several ballon and satellite experiments improved significantly our knowledge of cosmic ray (CR) spectra at high energy. In particular CREAM allowed to measure B/C, C/O and N/O ratios up to 1 TeV/n and PAMELA the anti p/p ratio up to 100 GeV with unprecedented accuracy. These measurements offer a valuable probe of CR propagation properties. We performed a statistical analysis to test the compatibility of these results, as well as other most significant experimental data, with the predictions of a new numerical CR diffusion package (DRAGON). We found that above 1 GeV/n all data are consistent with a plain diffusion scenario and point to well defined ranges for the normalization and energy dependence of the diffusion coefficient. (orig.)
The techniques in order to measure the depth of defect in weldment and structure accurately have been developed. Many researches have made efforts to develop the methods for the accurate depth sizing of defect. TOFD is known as the most accurate method of various methods for measuring depth sizing. However, there is a possibility to miss defects because of the limitation of beam coverage for the ultrasound incident angle. In this study, the results for detectability and depth sizing using phased array ultrasonic technique for thick body were compared with those of conventional TOFD technique. It was experimentally confirmed that the phased array ultrasonic TOFD technique gives good detectability and accurate depth measurement for the various types of defects. The phased array ultrasonic TOFD technique developed in this study will contribute to increase the inspection reliability in thick component such ...
We have measured the almost-pure incoherent scattering function of liquid and solid parahydrogen, using inelastic neutron scattering. The experiments were carried out on TOSCA, a time-of-flight, inverse-geometry, crystal-analyzer spectrometer, operating on the pulsed neutron source at ISIS (UK). The experiments have been planned taking advantage of the intrinsic incoherence introduced in the scattering process by the rotational transitions. The measured double-differential cross section gives a direct experimental access to the microscopic dynamics of condensed hydrogen. From the high-energy region of the spectrum, where the impulse approximation for the center of mass motion applies, we have been able to extract the translational mean kinetic energy. In the low-energy region, using the Gaussian approximation, we compare the experimental data in the liquid phase with the results of a model for the velocity autocorrelation ...
We report results of measurements and analysis of the heat capacity of MnSi. The measurements included data collection at a magnetic field of 4T, which suppresses strongly the longitudinal spin fluctuations and the phase transition. To analyze the experimental data, calculations of the phonon spectrum and phonon density of states in MnSi were performed. Inelastic neutron scattering with a polycrystalline sample of MnSi was used to validate the computational results. The combination of the experimental and theoretical data turned out to be decisive in revealing some hidden features of the thermal excitations in MnSi. In particular, the analysis of the available data led conclusively to the existence of a negative contribution to the heat capacity and entropy in MnSi at T>Tc, implying that a specific spin ordering process did occur in the paramagnet phase of MnSi.
Moss-Schottky plots and photoelectrochemical measurements were made on films formed at different potentials on AISI 304 stainless steel in a borate/boric acid solution, pH 9.2. The results allowed the determination of the semiconductive properties and band structure of the films, which account for the existence of two kinds of films depending on the formation potential. For potentials below 0 V (SCE), the results point out for a film with an inverse spinel structure constituted by Cr-substituted magnetite with two donor levels. Above 0 V only one donor level is detected, which should be Fe{sup 2 +} on tetrahedral sites.
Moss-Schottky plots and photoelectrochemical measurements were made on films formed at different potentials on AISI 304 stainless steel in a borate/boric acid solution, pH 9.2. The results allowed the determination of the semiconductive properties and band structure of the films, which account for the existence of two kinds of films depending on the formation potential. For potentials below 0 V (SCE), the results point out for a film with an inverse spinel structure constituted by Cr-substituted magnetite with two donor levels. Above 0 V only one donor level is detected, which should be Fe"2 "+ on tetrahedral sites.
We report here results of an application of single-nucleon stripping reactions at high energies (65 MeV/u) in inverse kinematics to obtain spectroscopic factors. From measurements of the partial cross-sections for ground and excited states in residual nuclei formed in one-proton stripping reactions, single particle orbits and occupancies of light nuclei have been studied in the s-d shell. Single proton stripping cross-sections of {sup 25}Al and {sup 26,27,28}P on a Be target have been measured using the S800 spectrograph and the NaI(Tl) array at the NSCL. These results indicate that this technique may provide a general tool for the intermediate energy range analogous to transfer (pick-up) reactions at low-energy.
We report here results of an application of single-nucleon stripping reactions at high energies (65 MeV/u) in inverse kinematics to obtain spectroscopic factors. From measurements of the partial cross-sections for ground and excited states in residual nuclei formed in one-proton stripping reactions, single particle orbits and occupancies of light nuclei have been studied in the s-d shell. Single proton stripping cross-sections of "2"5Al and "2"6","2"7","2"8P on a Be target have been measured using the S800 spectrograph and the NaI(Tl) array at the NSCL. These results indicate that this technique may provide a general tool for the intermediate energy range analogous to transfer (pick-up) reactions at low-energy.
The design and construction of a Browne-Buechner type round pole face magnetic electron spectrograph is described. The design is based on the first order transfer properties of the bending magnet including the focal surface, dispersion, magnification and resolution. Second order aberrations are compared wit numerical ray tracing results using measured field data to simulate the magnet. The numerical results are also compared with floating wire measurements on the system. Agreement is within one part in 10"4. Data extraction from the instrument is done with an array of copper detectors placed along the focal surface. The spectrograph has been successfully employed in free-electron laser (FEL) experiments for over a year.
Water vapor is well known to be a critical component in many aspects of atmospheric research, such as radiative transfer and cloud and aerosol processes. This requires both improved measurements of the columnar water vapor and its profiles in the atmosphere in a wide range of conditions, and adjustment of water vapor parameterizations in radiation codes including the perfection of spectroscopic parameters. In this paper we will present the results of comparison of our calculations and downward solar fluxes measured with Rotating Shadowband Spectroradiometer under conditions of horizontally homogeneous clouds. We also will discuss the sensitivity of atmospheric radiation characteristics to variations of water vapor in the band 940 nm: these results may be useful for development of new methods of retrieval of the total column water vapor content (WVC) in the atmosphere from data of radiation observations.
A mathematical model of multichannel radiometric inspection system was developed, in which the measurementresults are reproduced in the form of a half-tone image equivalent to the radiation image of the irradiated object. The model makes the following assumptions: the beam of radiation is fan-shaped; the object of inspection is scanned discretely; the focal spot of the source is rectangular; the apertures of the detector are round, and the detectors themselves are equidistant from the sources, aimed at it, and form a close-packed array; the signals from the detectors are processed according to a time scheme; and the measurementresults are corrected in a computer for normalizing the gains of the channels of the system. The mathematical model can serve as the basis for developing a method of calculating the optimal parameters of a multichannel radiometric system with visualization of the radiation ...
Within the framework of the MINEO research project assisted by the European Union the Deutsche Steinkohle AG (DSK) has developed methods for the operational use of remote sensing data and geo-information systems for the regular observation, measurement and evaluation of environmental effects in mining areas. Only indirect environmental effects of the mining industry, which may result in particular from subsidence-induced changes in the hydrological situation (ground water level, drainage) and the resulting effects on the vegetation and land utilisation, can be observed for the DSK test area 'Kirchheller Heide' because of the underground mine workings. Hence the evaluations of the remote sensing data were concentrated on the development of methods to measure and analyse the vegetation condition and any changes. MINEO thus constitutes a module for the DSK environmental information ...
A new method for analysis and design of smoothing reactances utilising two-dimensional planar models is presented in this paper. Inductance and magnetic flux density are calculated, and their results compared with those measured experimentally. The results obtained are good if compared with those measured once the machine have been built. Moreover, the method herein developed is applied to the calculation of air gap lengths in terms of the desired current and inductance. The kind of reactances studied presents windings in both limbs and air gaps in the four corners (joint of limbs and yokes). The main contribution of this paper is the presentation of a method of industrial application, to be easily developed, with a very important reduction in the time of machine calculation (due to the decrease in the number of nodes and elements compared with the three-dimensional model) for the determination of the ...
The half-value thicknesses, linear and mass attenuation coefficients of biological samples such as bone, muscle, fat and water have been measured at 140, 364 and 662keV ?-ray energies by using the ATOMLABTM-930 medical spectrometer. The ?-rays were obtained from 99mTc, 131I and 137Cs ?-ray point sources. Also theoretical calculations have been performed in order to obtain the half-value thicknesses and, mass and linear attenuation coefficients at photon energies 0.001keV-20MeV for bone, muscle and water samples. The calculated value and the experimental results of this work and the other results in literature are found to be in good agreement.
Many of the vulnerabilities to Energy Access, Energy Security, and Environmental Sustainability result from impediments to reaching a global demand-supply balance, as well as local balances, for various energy sources and carriers. Vulnerabilities result from multiple reasons: regional imbalances of energy production and consumption, the bulky character of the majority of energy fuels, the virtual necessity of electricity consumption following its production, among others. To detect and prioritize respective 'bottlenecks' across energy carriers, they have to be measured. In this report, production, consumption, exports, and imports were measured across all major energy carriers for seven key regions of the world for three time frames-2008, 2020, and 2050. Imbalances between production and consumption form bottlenecks in each region.
Non-isothermal TG/DTG measurements are widely used to determine kinetic parameters of oxidation and gasification of carbons, e.g. by multi-heating rate methods. Thereby it is important to avoid spurious effects due to diffusion limitations. In this work, TG/DTG experiments with activated carbon were conducted under isothermal and non-isothermal conditions. The agreement of the experimental results with results of simulations based on the intrinsic kinetics, pore diffusion and external diffusion in/to the sample (crucible) is very good. The simulations show that mass transfer has an unwanted influence on TG measurements, if the concentration of the gaseous reactant (O2 and CO2) is too low and/or the heating rate is too high. Based on literature data, the simulation was extended to blast fur...
To more accurately measure fluorescent signals from microarrays, we calibrated our acquisition and analysis systems by using groundtruth samples comprised of known quantities of red and green gene-specific DNA probes hybridized to cDNA targets. We imaged the slides with a full-field, white light CCD imager and analyzed them with our custom analysis software. Here we compare, for multiple genes, results obtained with and without preprocessing (alignment, color crosstalk compensation, dark field subtraction, and integration time). We also evaluate the accuracy of various image processing and analysis techniques (background subtraction, segmentation, quantitation and normalization). This methodology calibrates and validates our system for accurate quantitative measurement of microarrays. Specifically, we show that preprocessing the images produces results significantly closer to the known ground-truth for ...
The formaldehyde surface emission monitor (FSEM) has been developed for passive non-destructive measurement of formaldehyde (CH/sub 2/O) emission rates from CH/sub 2/O resin-containing materials. It is envisaged as a potential quality control and in-situ monitoring technique. For quality control applications to pressed-wood products, strong correlations between the results of the FSEM and environmentally controlled (small scale) chamber tests were observed. The FSEM is used to measure the cumulative CH/sub 2/O emission from a finite area of pressed-wood product during a fixed test period. The final result is reported as an average CH/sub 2/O emission rate (mg CH/sub 2/O/m/sup 2/h).
Sand-filled splash cups were used to study the erosive power of rainfall and throughfall in the humid subtropics of Southeast China. The splash cup measurements yielded precise and reproducible results under both open field conditions and forest vegetation. The splash cups were exposed to specific forest stands of different ages and to selected species (Schima superba, Castanopsis eyrei, Daphniphyllum oldhamii, Lithocarpus glaber) in the Gutianshan (???) National Nature Reserve (GNNR). The results of the measurements under forest vegetation show that the erosive power of throughfall drops to be 2.59 times higher compared to the open field. This accentuates the importance of shrub, herb and litter layers in forest ecosystems to protect the soil against erosion. Coalescing drops from leaves ...
N-type crystalline Si (100) implanted with 5 keV B ions was subsequently irradiated with MeV Si, O and F ions. The B atom profiles were measured by means of secondary ion mass spectrometer after the treatment of rapid thermal annealing. The results show that the transient enhanced diffusion of B atoms is effectively limited by the post-implantation of high energy ions at high dose. At the same irradiation conditions, it is found that the existence of a SiO_2 layer in the near surface of Si is even more effective in suppressing the transient enhanced diffusion of the doped B atoms. The results are qualitatively discussed in combination with the analyses of RBS/c measurements and calculation of the DICADA code
In this paper, the moisture buffering capacity of spruce plywood is measured by recording the change in mass of a test specimen when the air relative humidity (RH) is changed between 33% RH and 75% RH. The aim is to represent diurnal cycles in indoor humidity with 33% RH maintained for 16 h and 75% RH maintained for 8 h. Measurements are taken using two different apparatuses, which provide different convective transfer coefficients between the air and the plywood, and the results are compared to a numerical model for validation. The validated numerical model is then used to investigate the effect of initial conditions, boundary conditions and thickness on the moisture buffering capacity of plywood. The results show that the buffering capacity of plywood depends on the initial conditions and thickness of the plywood as well as the surface film coefficient and humidity cycle. (author)
Stoichiometric MgAl{sub 2}O{sub 4} spinel specimens irradiated in FFTF-MOTA at temperatures between 385 and 750C to fluences ranging from 2.2 to 24.9 {times} 10{sup 22}n cm{sup {minus}2} (E>0.1 MeV) darken significantly, but do not develop any significant loss in weight or change in dimensions. Similar behavior was observed in both single crystal and fully dense polycrystalline specimens. Measurements of elastic constants by an ultrasonic technique show that no measurable changes occur as a result of the irradiation. These and other results confirm the stability of this material for fusion application as an electrical insulator.
Off-axis electron holography is used to characterize a linear array of transistors, which was prepared for examination in cross-sectional geometry in the transmission electron microscope (TEM) using focused ion beam (FIB) milling from the substrate side of the semiconductor device. The measured electrostatic potential is compared with results obtained from TEM specimens prepared using the more conventional 'trench' FIB geometry. The use of carbon coating to remove specimen charging effects, which result in electrostatic fringing fields outside 'trench' specimens, is demonstrated. Such fringing fields are not observed after milling from the substrate side of the device. Analysis of the measured holographic phase images suggests that the electrically inactive layer on the surface of each FIB-milled specimen typically has a thickness of 100 nm.
Angular dependence from L_3-subshell to M-shell vacancy transfer probabilities for selected heavy elements from Au to U have been measured by using a Si(Li) detector coupled to a model 1024 computerized multi-channel analyzer. Because the angular dependence from L_3-subshell to M-shell vacancy transfer probabilities is not found in the literature, to the best of our knowledge there are no experimental values for worked elements. Therefore, the results for the elements obtained in the present study constitute the first experimental measurements; the comparison has been not made with other experimental and theoretical results. It has been observed that angular dependence from L_3-subshell to M-shell vacancy transfer probabilities increase with increasing cos #theta#.
Recent data on {eta} -meson photoproduction off a proton target in the energy range 2 {<=}{radical}(s){<=} 3 GeV are analyzed with regard to their overall consistency. Results from the ELSA and CLAS measurements are compared with predictions of a Regge model whose reaction amplitude was fixed via a global fit to pre-2000 measurements of differential cross sections and polarization observables for {gamma}p{yields}{eta}p at higher energies. We find that all recent experimental results on differential cross sections for {eta} -meson photoproduction are in good agreement with each other, except for the CLAS data from 2009. However, the latter can be made consistent with the other data at the expense of introducing an energy-dependent renormalization factor. We point out that there are indications in the data for a possible excitation of baryon resonances with masses around 2.1 and 2.4GeV. ...
A brief survey of present air pollution abatement requirements relevant to domestic heating systems is followed by a comparative evaluation of the latest results worked out on the part of boiler and burner manufacturers, and the legal requirements and existing regulations. Details are given on the limiting values required by law, the regulations valid for domestic heating systems, and the values fixed according to scientific knowledge and research results (development of NO{sub x} and CO, flame temperature dependence, table comparing CO and NO{sub x} limiting values for different types of burners and boilers). Access is given to primary air pollution abatement measures (cooling of flames, absorber rods, influence of mixing pressure), modern burner and boiler systems, and secondary measures suited for smaller boilers. (HWJ).
A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with the detector are ...
A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with the detector are ...
Presented here is the calculation results of tidal field of Daya Bay by using pseudospectral method. According to the calculation results about the tidal field and measured value of wind in Daya Bay area, the diffusion of radionuclide from Daya Bay Nuclear Power Plant is simulated by using particle random walk model. The simulation results about the relative concentration distribution of the radionuclides and the trajectory of the distribution centrode are obtained, taking account of tidal current, wind and turbulent current. These results can provide information not only for the reasonable discharge of the radionuclides from Daya Bay Nuclear Power Plant, but also for understanding the potential effect on environment due to the normal operation of Daya Bay Nuclear Power Plant. (authors)
To predict the response of blood lead to airborne and dietary lead requires knowledge of the rate of uptake of lead into the body from lung and gut, its subsequent partitioning between compartments, the stay time in those compartments, and its redistribution or excretion. Tracer studies with volunteers have shown no differences in systemic distribution of inorganic lead between tissues whether it is taken by inhalation, ingestion or injection. Lead is rapidly transferred from plasma to red cells, and there is slower movement thence into liver and other soft tissues, to bone, and to excreta. Work at Harwell and elsewhere with /sup 203/Pb has shown that the initial rapid distribution leaves rather over half the assimilated lead attached to red cells. The result is remarkably consistent, and applies also to dogs and baboons. The renal clearance (Vu) (ratio of U to CB, or daily urinary output expressed as mass of blood having the same lead content), and also the ...
Consistent application of a newly developed coincidence technique to determine activation products in the operation and demolition of nuclear facilities results in very new perspectives in contamination monitoring and clearance measurement of plant components. In particular, it is possible to avoid the critical spread of point-source Co-60 contamination, the so-called hot particles. The CCM (Cobalt Coincidence Measurement) technique includes the coincident detection of prompt-prompt gamma cascades with "6"0Co and other activation products ("1"1"0"mAg, "1"2"4Sb, "2"2Na) with low mass-specific limits for unrestricted clearance. Special features of the technique are the short measurement times, excellent signal-to-noise ratio, and focusing in space achieved. Compared to conventional integral gamma-measurements, the signal-to-background ratio can be improved by 1-2 orders of magnitude. ...
A three-dimensional numerical simulation of the loss-of-feed water transient at the horizontal steam generator of the Kola nuclear power plant is performed. Presented numerical results show transient change of integral steam generator parameters, such as steam generation rate, water mass inventory, outlet reactor coolant temperature, as well as detailed distribution of shell side thermal-hydraulic parameters: swell and collapsed levels, void fraction distributions, mass flux vectors, etc. Numerical results are compared with measurements at the Kola NPP. The agreement is satisfactory, while differences are close to or below the measurement uncertainties. Obtained numerical results are the first ones that give complete insight into the three-dimensional and transient horizontal steam generator thermal-hydraulics. Also, the presented results serve as benchmark ...
E-35 reported the specific air flow analysis program using a CFSV model (including a human body model) to develop a high-accuracy evaluation simulator for heterogeneous thermal environment based on human thermal physiological conditions. E-36 reported development of the radiation heat transfer analysis module by using a numerical integral method to calculate shape factors. Radiation heat transfer characteristics every body part were clarified quantitatively by this module. E-37 reported the results on continuous measurement of physiological conditions and thermal environment factors every monitor under controlled indoor thermal environment, to collect measurement data necessary for improving the accuracy of a prediction program for human body temperatures. E-38 reported the study result on physiological reaction and subjective evaluation through an examinee experiment in a blood controlled region, to ...
The thermal contact resistance between balls and inner and outer rings of thermally steady space-use deep groove ball bearings was studied experimentally to verify the validity of the previously proposed calculation method for the resistance. The 440C stainless steel single row bearing was used for measuring its steady state temperature distributions in a vacuum environment under axial, radial and combined load conditions. As a result, the experimental results of the resistance well agreed with calculated ones under each load condition resulting in the sufficient validity at nearly the same surface roughness. It was necessary to apply a static equivalent radial load to calculation under the combined load that a contact angle is larger than the angle of resultant force dependent on both load components. In experiments under only radial load, measurement of outer ...
Aim: To create nomograms for renal size as measured from DMSA renal studies, and to test the nomograms for their ability to separate normal from abnormal kidneys. Method: Renal length was measured from posterior oblique views and renal area from posterior views. Results from 253 patients with bilateral normal kidneys were used to create nomograms for renal size relative to patient age, body height, weight or body surface area (BSA). The nomograms enclosed 95% of the normal kidneys, thus indicating the range for 95% confidence limits, and hence the specificity. Each nomogram was then tested against 46 hypertrophied kidneys and 46 damaged kidneys. Results: The results from nomograms of renal length and renal area, compared to age, body height, body weight and BSA are presented. For each nomogram, the range is presented as a fraction of the mean value, and the number of abnormal ...
The ``Passivhaus Darmstadt-Kranichstein`` is a 4 unit terrace house with an extremely low total annual energy consumption of less than 32 kWh/m{sup 2} of living area, thereof about 12 kWh are needed for room heating. The determining factors for the low consumption are the superinsulation, airtightness of the thermal envelope in combination with a highly efficient VAV ventilation system, and an improved window construction. The results of a detailed monitoring program allow decisive statements concerning reduction of energy consumption, relief of environment, indoor air quality, and thermal comfort. (author)
Four classrooms of two secondary schools located around Lyon in France have been monitored. The objectives are to analyse the quality of the indoor air and the thermal comfort and also the behaviour of the occupants towards opening of the windows. This paper briefly describes the context and the nature of the monitoring campaign, and presents the results of the measurements with direct interpretation of the ventilation needs. Results from this study show that allowable CO{sub 2} levels are overpassed several times in a school day. The presence of a mechanical ventilation system leads to lower peaks but the fresh airflow is too small to prevent an indoor confining, that is also revealed by the aerobiological analysis. (author)
Results are reported of photoemission studies using laser pulses of 10 ps duration and 4.66 eV photon energy on metal cathodes. These included thin wires, flat surfaces and an yttrium cathode with a grainy surface. The measurements of current density and quantum efficiency under low and high surface fields indicate that field assisted efficiencies exceeding 0.1% and current densities exceeding 10/sup 5/ A/cm/sup 2/ are obtainable. The results are compared to the requirements of switch power applications. 24 refs., 13 figs., 1 tab.
Measurements of the rate of heat transfer, enhanced by electroconvection, between two parallel plates have been carried out. Results show that the non-dimensional heat flux, or the Nusselt number, increases when an electric field acts on an injected space charge within the insulating liquid. The motion of the liquid depends on the electrical forces (Coulomb force) and the buoyancy effects have little or no influence. This is evident from steady state and time dependent results which show that for a given voltage, the Nusselt number takes the same value no matter what the flux of heat supplied to the bottom plate.
The authors present the emitter efficiency results for the thin film 25 percent Ho YAG (Yttrium Aluminum Garnet, Y3Al5O12) selective emitter from 1000 to 1700 K with a platinum substrate. Spectral emittance and emissive power measurements were made (1.2 less than lambda less than 3.2 microns) and used to calculate the radiative efficiency. The radiative efficiency and power density of rare earth doped selective emitters are strongly dependent on temperature and experimental results indicate an optimum temperature (1650 K for Ho YAG) for thermophotovoltaic (TPV) applications.
Tests for the applicability of a CFD (Computational Fluid Dynamics) code for simulating activity transport in PNA (Pulsed Neutron Activation) fluid measurements have been performed. The CFD code was combined with a Monte Carlo code used for the calculation of the initial activity distribution. The results from the calculations show that it is possible to use CFD for calculation of the activity distribution in PNA. The mainly qualitative results in this work are encouraging and suggest further work. In the continuation of this work a response function for the gamma detector will be calculated so that a PNA time spectrum can be simulated. A more accurate comparison with experimental data can then be performed
At the importance increase of UT (ultrasonic testing) with the application of rules on fitness-for-service for nuclear power plants, JAPEIC (Japan power engineering and inspection corporation) started education training for defect detection and sizing technique. Weld joints specimen with EDM (Electro-Discharged Machining) notches, fatigue cracks and intergranular stress corrosion cracks were tested and practiced repeatedly based on a modified ultrasonic method and the defect size measuring accuracy of the trainees was surely improved. Results of the blind test confirmed effectiveness of education training. (T. Tanaka)
The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. We have constructed and tested several versions of the BCS. The results are described.
The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. We have constructed and tested several versions of the BCS. The results are described.
In this paper we have investigated the performance of PSO Particle Swarm Optimization based clustering on few real world data sets and one artificial data set. The performances are measured by two metric namely quantization error and inter-cluster distance. The K means clustering algorithm is first implemented for all data sets, the results of which form the basis of comparison of PSO based approaches. We have explored different variants of PSO such as gbest, lbest ring, lbest vonneumann and Hybrid PSO for comparison purposes. The results reveal that PSO based clustering algorithms perform better compared to K means in all data sets.
The performance of a high temperature ion source coupled to a helium gas-jet transport system for an efficient mass separation of neutron-rich alkaline earth and lanthanide isotopes is reported and the results of overall efficiency measurements using different cluster materials in the gas-jet are given. A fast, microprocessor controlled tape transport system for ..gamma..-spectroscopic studies on short-lived isotopes is described. Some results on the decay of 3.8sub(-s) /sup 152/Pr are presented. (orig.).
The performance of a high temperature ion source coupled to a helium gas-jet transport system for an efficient mass separation of neutron-rich alkaline earth and lanthanide isotopes is reported and the results of overall efficiency measurements using different cluster materials in the gas-jet are given. A fast, microprocessor controlled tape transport system for ..gamma..-spectroscopic studies on short-lived isotopes is described. Some results on the decay of 3.8sub(-s) /sup 152/Pr are presented.
The phase transition is a performance measure of the sparsity-undersampling tradeoff in compressed sensing (CS). This letter reports, for the first time, the existence of an exact phase transition for the $\\ell_1$ minimization approach to the complex valued CS problem. This discovery is not only a complementary result to the known phase transition of the real valued CS but also shows considerable superiority of the phase transition of complex valued CS over that of the real valued CS. The results are obtained by extending the recently developed ONE-L1 algorithms to complex valued CS and applying their optimal and iterative solutions to empirically evaluate the phase transition.
The damage induced by low-temperature proton irradiation in amorphous Pd/sub 80/Si/sub 20/ prepared by ion implantation is studied via electrical resistivity measurements. Our experimental results concerning the initial damage rate and the resistivity saturation are compared to the results obtained for electron and high energy /sup 16/O irradiation of amorphous Pd/sub 80/Si/sub 20/ quenched from the melt. The resistivity curve is analyzed in terms of irradiation-induced point defects.
The level structure of the doubly-odd /sup 242/Am nucleus was investigated by means of thermal-neutron-capture gamma-ray and conversion electron spectroscopy. Pair, curved-crystal, and ..beta.. spectrometers were used. The data from these measurements, combined with previous direct reaction results, permit us to establish a detailed level scheme including six new well-developed bands. Our experimental results are interpreted in the framework of the Nilsson model. Precise Gallagher-Moszkowski splittings and Newby odd-even shifts extracted from the data are compared with theoretical calculations.
AbstractObjective To review studies investigating the brain correlates of unawareness of cognitive and behavioural symptoms in people with dementia. Design A detailed search of the literature was conducted to include all the peer-reviewed studies published in English aimed at identifying the structural or functional brain correspondents of unawareness in dementia patients. Their results were interpreted in relation to the methodological differences in terms of type of dementia studied, the protocol adopted to measure lack of awareness, the imaging techniques employed, the experimental designs and statistical analyses performed. Results Eighteen studies undertaken to explore the functional and structural correlates of unawareness of cognitive symptoms in dementia were identified. Although t...
Several short model SSC 50 mm bore dipoles are being built and tested at Fermilab. Mechanical design of these magnets has been determined from experience involved in the construction and testing of 40 mm dipoles. Construction experience includes coil winding, curing and measuring, coil end part design and fabrication, ground insulation, instrumentation, collaring and yoke assembly. Fabrication techniques are explained and construction problems are discussed. Similarities and differences from the 40 mm dipole tooling and management components are outlined. Test results from the first models are presented. 19 refs., 12 figs.
Effects of the rapid early-in-life expansion of metal fuel were measured in an irradiation experiment in the Fast Flux Test Facility (FFTF). This important performance/design information was obtainable through the unique combination of a dimensionally stable FFTF oxide core and the calibrated proximity instrumentation associated with the test. These results delineate the time dependence of metal-fuel swelling and provide quantitative estimates of the magnitude of axial fuel swelling in full-length metal-fuel assemblies. Final posttest examination results will define actual fuel column growth levels.
In this letter, they present the results on a global fit to precision electroweak data in a Higgs triplet model. In models with a triplet Higgs boson, a consistent renormalization scheme differs from that of the Standard Model and the global fit shows that a light Higgs boson with mass of 100-200 GeV is preferred. Triplet Higgs bosons arise in many extensions of the Standard Model, including the left-right model and the Little Higgs models. The result demonstrates the importance of the scalar loops when there is a large mass splitting between the heavy scalars. It also indicates the significance of the global fit.
Objective: Results of reliability and agreement studies are intended to provide information about the amount of error inherent in any diagnosis, score, or measurement. The level of reliability and agreement among users of scales, instruments, or classifications is widely unknown. Therefore, there is a need for rigorously conducted interrater and intrarater reliability and agreement studies. Information about sample selection, study design, and statistical analysis is often incomplete. Because of inadequate reporting, interpretation and synthesis of study results are often difficult. Widely accepted criteria, standards, or guidelines for reporting reliability and agreement in the health care and medical field are lacking. The objective was to develop guidelines for reporting reliability and...
A theoretical study of structural and electronic properties of GeC, SnC and GeSn is presented using the full potential linearized augmented plane wave method. In this approach, the generalized gradient approximation was used for the exchange-correlation potential. Results are given for lattice constant, bulk modulus and its pressure derivative in both zinc-blende and rocksalt structures. Band structure, density of states and band gap pressure coefficients in zinc-blende structure are also given. The results are compared with previous calculations and with experimental measurements.
The design and first results from a Double Sided Silicon Strip Detector (DSSSD) recently installed at the Lund Nuclear Microprobe facility (NMP) are presented. The detector has 64 sector strips and 32 ring strips, which in combination give more than 2000 detector cells, each with characteristics comparable with a standard surface barrier detector (SBD). The detector has been tested both with radioactive sources and with different ion beams and energies. The most striking features are the high rate virtually pile-up free operation and also the possibility of detailed measurement of angular distributions.
The design and first results from a Double Sided Silicon Strip Detector (DSSSD) recently installed at the Lund Nuclear Microprobe facility (NMP) are presented. The detector has 64 sector strips and 32 ring strips, which in combination give more than 2000 detector cells, each with characteristics comparable with a standard surface barrier detector (SBD). The detector has been tested both with radioactive sources and with different ion beams and energies. The most striking features are the high rate virtually pile-up free operation and also the possibility of detailed measurement of angular distributions.
Thin films of high temperature garnet materials such as yttrium aluminum garnet (YAG) doped with rare earths are currently being investigated as selective emitters. This paper presents a radiative transfer analysis of the thin film emitter. From this analysis the emitter efficiency and power density are calculated. Results based on measured extinction coefficients for erbium-YAG and holmium-YAG are presented. These results indicated that emitter efficiencies of 50 percent and power densities of several watts/sq cm are attainable at moderate temperatures (less than 1750 K).
To maintain quality, performance and competitiveness, the eddy current losses in metal parts of power transformers in the range of 50-200 MVA are investigated in a more detailed form. The finite element calculations utilize different modelling strategies for the current carrying metal parts. Several global and local results are further used to obtain simplified calculation approaches for an inclusion in the initial design and the design optimization. The results from two finite element approaches using nodal and edge based formulations will be compared with measurements. (Author)
A hyperbolic Stefan problem based on the linearized Gurtin-Pipkin heat conduction law is considered. The temperature and free boundary are controlled by a thermostat acting on the boundary. This feedback control is based on temperature measurements performed by real thermal sensors located within the domain containing the two-phase system and/or at its boundary. Three different types of thermostats are analyzed: simple switch, relay switch, and a Preisach hysteresis operator. The resulting models lead to integrodifferential hyperbolic Stefan problems with nonlinear and nonlocal boundary conditions. Existence results are proved in all the cases. Uniqueness is also shown, except in the situation corresponding to the ideal switch.
The use of the method is described on powder samples before and after sintering with a La content of up to 1%. For excitation of the K series of La a /sup 241/Am source with an activity of 1.11 GBq was used. The obtained results showed that the method is sufficiently accurate (error 7%) at a short period of measurement (100 s). It gives satisfactory results even in the comparison of the experimental relative count rate and the theoretically calculated value despite the fact that the analytical signal comes from the sample surface.
The use of the method is described on powder samples before and after sintering with an La content of up to 1%. For excitation of the K series of La a _2_4_1Am source with an activity of 1.11 GBq was used. The obtained results showed that the method is sufficiently accurate (error 7%) at a short period of measurement (100 s). It gives satisfactory results even in the comparison of the experimental relative count rate and the theoretically calculated value despite the fact that the analytical signal comes from the sample surface. (Ha).
The properties of the passive films formed on Alloy 600 at different applied potentials in 10% NaOH solution at 315 .deg. C was studied using in situ AC impedance and polarization measurements. The results were correlated with the stress corrosion cracking (SCC) behavior obtained from the C-ring tests in the same conditions. The change of the semiconductive property and the peak of relaxation time were observed at 0.2 V where the SCC rate showed a maximum. These results were also consistent with the prediction parameter for SCC obtained from fast and slow polarization scans.
The purpose of this study was to use high-resolution magnetic resonance (MR) imaging combined with image analysis to investigate the three-dimensional (3D) trabecular structure, anisotropy, and connectivity of human vertebral, femoral, and calcaneal specimens. The goal was to determine whether: (a) MR-derived measures depict known skeletal-site-specific differences in architecture and orientation of trabeculae; (b) 3D architectural parameters combined with bone mineral density (BMD) improve the prediction of the elastic modulus using a fabric tensor formulation; (c) MR-derived 3D architectural parameters combined with BMD improve the prediction of strength using a multiple regression model, and whether these results corresponded to the results obtained using higher resolution depictions of trabecular architecture. A total of 94 specimens (12 x 12 x 12 mm cubes) consisting of trabecular bone only were obtained, of which ...
A theoretical model is developed to explain variations in airborne gamma-ray measurements over a calibration range near Ottawa, Ontario. The gamma-ray flux from potassium and the thorium decay series showed an expected decrease with increasing soil moisture. However, the gamma-ray flux from the uranium decay series was highest in the spring when the ground was water-saturated and even covered with snow. These results are explained through the build-up of radon and its associated gamma-ray-emitting decay products in the clay soil of the calibration range with increasing soil moisture. Similar results were found from airborne measurements over other clay soils. However, measurements over sandy soils showed that the count rates from all three radio elements increased with decreasing soil moisture. This difference between soil types was attributed to the lower radon emanation of the ...
A theoretical model is developed to explain variations in airborne gamma-ray measurements over a calibration range near Ottawa, Ontario. The gamma-ray flux from potassium and the thorium decay series showed an expected decrease with increasing soil moisture. However, the gamma-ray flux from the uranium decay series was highest in the spring when the ground was water-saturated and even covered with snow. These results are explained through the build-up of radon and its associated gamma-ray-emitting decay products in the clay soil of the calibration range with increasing soil moisture. Similar results were found from airborne measurements over other clay soils. However, measurements over sandy soils showed that the count rates from all three radio elements increased with decreasing soil moisture. This difference between soil types was attributed to the lower radon emanation of the ...
The ORNL high temperature isopiestic apparatus was adapted for adsorption measurements. The quantity of water retained by rock samples taken from three different wells of The Geysers was measured at 150 °C and at 200 °C as a function of pressure in the range 0.00 ≤ p/p0 ≤ 0.98, where p0 is the saturated water vapor pressure. The rocks were crushed and sieved into three fractions of different grain sizes (with different specific surface areas). Both adsorption (increasing pressure) and desorption (decreasing pressure) runs were made in order to investigate the nature and extent of the hysteresis. Additionally, BET surface area analyses were performed by Porous Materials Inc. on the same rock samples using nitrogen or krypton adsorption measurements at 77 K. Specific surface areas and pore volumes were determined. These parameters are important in ...
For the lifetime evaluation of plasma facing materials in fusion experimental machines, it is essential to investigate their surface behavior and their temperature responses during an off-normal event such as the plasma disruptions. An infrared thermometer with a sampling speed as fast as 1x10"-"6 s/data, namely, the high-speed infrared thermometer (HSIR), has been developed by the National Research Laboratory of Metrology in Japan. To evaluate an applicability of the newly developed HSIR on the surface temperature measurement of plasma facing materials, high heat flux beam irradiation experiments have been performed with three different materials under the surface heat fluxes up to 170 MW/m"2 for 0.04 s in a hydrogen ion beam test facility at the Japan Atomic Energy Research Institute. As for the results, HSIR can be applicable for measuring the surface temperature responses of the armor tile materials with a little ...
The "2"3"3U(n,f) cross section has been measured at the white neutron source n_TOF in a wide energy range with a dedicated fission ionization chamber. We report here the results from #approx#30 meV to 1 MeV neutron energy. The "2"3"3U(n,f) cross section has been determined relative to a reference sample of "2"3"5U(n,f) measured simultaneously with the same detector. The very high instantaneous neutron flux and the intrinsically low background of the n_TOF installation result in an accuracy around 3% in the whole energy range, while the energy resolution of the neutron beam allows for an accurate description of the fission cross section by means of R-matrix analysis over a wide energy range. The results are, in general, in good agreement with the most recent high-accuracy measurement of this fission cross section, over the more limited range of the previous ...
We investigate the efficacy of mitigating radiation-based single event effects (SEE) within circuits incorporating SiGe heterojunction bipolar transistors (HBTs) built with an N-Ring, a transistor-level layout-based radiation hardened by design (RHBD) technique. Previous work of single-device ion-beam induced charge collection (IBICC) studies has demonstrated significant reductions in peak collector charge collection and sensitive area for charge collection; however, few circuit studies using this technique have been performed. Transient studies performed with Sandia National Laboratory's (SNL) 36 MeV 16O microbeam on voltage references built with N-Ring SiGe HBTs have shown mixed results, with reductions in the number of large voltage disruptions in addition to new sensitive areas of low-level output voltage disturbances. Similar discrepancies between device-level IBICC results and circuit measurements are found for the ...
In this report, we outline the progress achieved in two distinct under the DOE-sponsored cross section project: the initial results obtained from the pulsed 14 MeV neutron facility, and a cooperative effort with Argonne National Laboratory in the measurement of fast neutron cross sections in yttrium. In the 14 MeV neutron laboratory, this year has seen the maturation of the project into one in which initial scattering measurements are now underway. We have improved the accelerator and ion source in several significant ways, so that neutron intensities have now been proven to be adequate for our series of elastic scattering angular distribution measurements outlined in our initial proposal of two years ago. We have successfully tested all components of the time-of-flight spectrometer and recorded initial neutron spectra from the ring targets that we have obtained for our first angular distribution ...
Objectives: To investigate optical coherence tomography consistency on foveal thickness, foveal volume, and macular volume measurements in patients with and without diffuse diabetic macular edema. Introduction: Optical coherence tomography represents an objective technique that provides cross-sectional tomographs of retinal structure in vivo. However, it is expected that poor fixation ability, as seen in diabetic macular edema, could alter its results. Several authors have discussed the reproducibility of optical coherence tomography, but only a few have addressed the topic with respect to diabetic maculopathy. Methods: The study recruited diabetic patients without clinically evident retinopathy (control group) and with diffuse macular edema (case group). Only one eye of each patient was evaluated. Five consecutive fast macular scans were taken using Ocular Coherence Tomography 3; the 6 mm macular map was chosen. The consistency in ...
Abstract Background: Aution Max AX-4030, a test strip analyzer recently introduced to the market, represents an upgrade of the Aution Max AX-4280 widely employed for urinalysis. This new instrument model can allocate two different test strips at the same time. In the present study the two instruments have been compared together with the usage of Uriflet 9UB and the recently produced Aution Sticks 10PA urine strips, the latter presenting an additional test area for the measurement of urinary creatinine. Methods: Imprecision and correlation between instruments and strips have been evaluated for chemical-physical parameters. Accuracy was evaluated for protein, glucose and creatinine by comparing the semi-quantitative results to those obtained by quantitative methods. The well-known interference effect of high ascorbic acid levels on urine glucose test strip determination was evaluated, ascorbic acid influence was also evaluated on protein and ...
Radionuclide X-ray fluorescence analysis is a method, which has many advantages for analysing various historic artefacts, as it is relatively cheap, sensitive and non-destructive, and it allows measurements in-situ. However, this analysis has also certain limitations especially concerning sensitivity to chemical elements only, irrespective of the compounds or chemical forms in which these elements have been bonded. In addition, light elements emitting very soft X-rays cannot be measured, and in order to detect a wide range of elements, it is necessary to carry out repeated measurements with different radiation sources. Despite these limitations, valuable information can be obtained about the composition of historic materials and data about the origin and age of these artefacts can be derived. Analyses of wall paintings, ancient metal sculptures or other objects of art provide the basis for historic considerations documented ...
Radionuclide X-ray fluorescence analysis is a method, which has many advantages for analysing various historic artefacts, as it is relatively cheap, sensitive and non-destructive, and it allows measurements in-situ. However, this analysis has also certain limitations especially concerning sensitivity to chemical elements only, irrespective of the compounds or chemical forms in which these elements have been bonded. In addition, light elements emitting very soft X-rays cannot be measured, and in order to detect a wide range of elements, it is necessary to carry out repeated measurements with different radiation sources. Despite these limitations, valuable information can be obtained about the composition of historic materials and data about the origin and age of these artefacts can be derived. Analyses of wall paintings, ancient metal sculptures or other objects of art provide the basis for historic considerations documented ...
Experiments were performed to measure the transfer of trichloroethylene (TCE), a volatile organic compound (VOC), from tap water in showers to indoor air. In these experiments, the loss of TCE from tap water in the shower is based on the difference between influent and effluent concentrations.We have developed and previously published a three-compartment model, which we use to simulate the 24-h concentration history of VOCs in the shower, bathroom, and remaining household volumes resulting from the use of contaminated tap water. An important input to this model is the transfer efficiency of the VOC from water to air. The experiments reveal that the transfer efficiency of TCE from shower water to air has an arithmetic mean value of 51 percent and an arithmetic standard deviation of 9 percent. Analysis of the results shows that there is no statistically significant difference between the transfer efficiency ...
In this study, the results of atmospheric radon measurements that were performed for the Amasra underground coal mine in Zonguldak bituminous coal basin (Turkey) are presented. The radon measurements were performed for 40 days between November 2004 and December 2004 using passive nuclear etched track detectors. The radon concentrations vary from a minimum value 49 Bq m{sup -3} in a site located at +40 m to a maximum value 223 Bq m{sup -3} in a site located at -100 m. Mean concentration is 117 (Bq m{sup -3}). This value is well below the action level of 500-1500 Bq m{sup -3} recommended by the International Commission on Radiological Protection (ICRP) (1993). The mean effective dose value for workers of this mine of 3.4 {mu} Sv per day was obtained. This result shows that protection against radiological hazards would not be necessary for workers of this mine.
This work presents an experimental and numerical study of pulsated Dean flow, three-dimensional pulsatile flow in a curved pipe. The numerical study is performed by CFD code (Fluent 6) in which a pulsated velocity field is imposed as an inlet condition. The experimental setup involves principally a 'Scotch-yoke' pulsatile generator and a 90o bend. Laser Doppler Velocimetry (LDV) measurements have shown that the Scotch-yoke generator produces pure sinusoidal instantaneous mean velocities with a mean deviation of 3%. Visualizations by laser-induced fluorescence (LIF) and velocity measurements, coupled with the numerical results, have permitted analysis of the evolution of the swirling secondary flow structures that develop along the bend during the pulsation phase. These measurements were made for a range of stationary Reynolds number (300?Rest?1200), frequency parameter (1??=r0(?/?)1/2max,osc/Ust). We ...
Calculations have been made to determine the production of "1"8"8W from "1"8"6W in several US fission reactor systems, e.g., Fast Flux Test Facility (FFTF), the High Flux Isotope Reactor (HFIR), and the Advanced Test Reactor (ATR). Important input to these calculations are the cross-section parameters for "1"8"6W, "1"8"7W, and "1"8"8W. Only two values have been measured for "1"8"7W and none for "1"8"8W. Consequently, results from integral measurements play a crucial role in determining the "1"8"7W and "1"8"8W values. This has been studied for irradiations in the FFTF and the Oregon State Univ. (OSU) research reactor. Short irradiation of enriched "1"8"6W in both the FFTF and the OSU reactors have produced #mu#Ci/g quantities of "1"8"8W/"1"8"8Re. Measurements were made of the "1"8"8W gamma ray emission. These results were incorporated with other available data to provide more ...
Differential elastic and inelastic neutron-scattering cross sections of elemental iron are measured from 4.5 to 10 MeV in increments of {approx}0.5 MeV. The measurements are made at >or{approx}40 scattering angles distributed between {approx}17 and 160 , with emphasis on elastic scattering and inelastic scattering due to the excitation of the yrast 2{sup +} state. The measured data is combined with earlier lower-energy results from this laboratory, with recent high-precision {approx}9.5-15 MeV results from the Physikalisch. Technische Bundesanstalt and with selected values from the literature to provide a detailed neutron-scattering data base extending from {approx}1.5 to 26 MeV. This data is interpreted in the context of spherical-optical and coupled-channels (vibrational and rotational) models, and the physical implications are discussed. Deformation, coupling, asymmetry and ...
The "2"3"3U(n, f) cross-section has been measured at n_TOF in a wide energy range with a dedicated fission ionization chamber. We report here the results from 0.30 meV to 1 MeV neutron energy. The "2"3"3U(n, f) cross-section has been determined relative to a reference sample of "2"3"5U(n, f) measured simultaneously with the same detector. The very high instantaneous neutron flux and the intrinsically low background of the n TOF installation result in an accuracy around 3% in the whole energy range, while the energy resolution of the neutron beam allows for an accurate description of the fission cross-section by means of R-matrix analysis over a wide energy range. The present data provide the basis for a more precise evaluation of the "2"3"3U fission cross-section, and for improving the reliability of databases needed for the design of new energy systems based on the Th/U cycle. (Author)
Individual monitoring of personal exposure to inhalation of uranium oxides throughout the manufacture of fuel for pressurized water reactor (PWR) includes lung gamma-spectrometry, fecal analysis and urine analysis. Examination of the results shows the following: internal exposure is the consequence of repeated intake incidents as revealed by early peaks of urinary and particularly fecal elimination; a shift is often observed with the results of aerosol concentration measured through air collectors; the measured variations of uranium lung incorporations are relatively fast (apparent mean period 165 d). Correct evaluation of the effective dose equivalent from inhalation requires further information concerning the aerosol size distribution at work stations, the physico-chemical characteristics of the product leading to an estimate of its actual biological solubility, and the ...
Industrial applications of thermoplastic polymers are often limited by their poor adhesion properties. In this work the effect of surface oxyfluorination on the adhesion properties was investigated for polyethylene (PE), polyoxymethylene (POM), polybutylene terephthalate (PBT) and polyamide 6 (PA6). The adhesive joint strength was quantified using lap-shear tests. These results were correlated with the changes in the chemical composition of the surface, determined by X-ray photoelectron spectroscopy (XPS), in the surface free energy, measured by the contact angle method, and in the topography, using white-light confocal microscopy. The adhesive strength is strongly improved for all four polymers, but the degree of this increase depends on the polymer type. The surface free energy shows a similar trend for all four polymers. A high surface free energy exceeding 50 mN/m was observed after oxy-fluorination, whereby the polar component was strongly ...
For the purpose of proposing it to ISO, the R and D were conducted of a new evaluation method of thermal properties of polymer materials. The FY 1999 results were summarized. In this fiscal year, the development of the ac Joule heating equipment was proceeded with based on the study at the technical committee, and the measuring device was installed. In the comparative measurement with conventional methods, study was proceeded with of the laser flash method, AC calorimetry method and specific heat measurement. In the technical survey, the developmental state of the ac method, especially, was examined as a testing method of thermal properties of polymer materials. It is in the stage of the basic research by keyword selection, and the search for literature is to be made in full scale. As to the needs in the industrial circle, as a result of the questionnaire survey made, it was found ...
The energy resolution of small NaI(Tl), CsI(Tl), BGO, GSO, YAP and LSO crystals has been studied using 16 mm diameter large area avalanche photodiodes (LAAPD) and a 52 mm diameter photomultiplier. The best result of 4.8% for 662 keV #gamma#-rays from a "1"3"7Cs source was obtained with a 9 mm in diameter by 9 mm high CsI(Tl) scintillator coupled to an LAAPD. Measuring the number of primary electron-hole pairs produced in the LAAPD and photoelectrons in the photomultiplier, as well as the noise contribution of the LAAPD, allowed a quantitative discussion of the results. The energy resolutions measured with LAAPDs are comparable to, or significantly better (at certain emission wavelengths) than, those obtained with the photomultiplier. At energies above 100 keV the energy resolution measured with the majority of crystals and the LAAPD was weakly affected by the photodiode noise ...
The polarization of extracted SATURNE II proton beam as a function of different ion source configurations was studied. Two distinct experiments were necessary for this purpose. In the first one, the left-right instrumental asymmetry of the beam polarimeter was determined using an unpolarized beam. In the second one this correction factor was applied to asymmetries measured with the beam from the polarized ion source in all polarization states. The measurements were carried out at the proton beam kinetic energy 0.80 GeV, where the pp-elastic scattering analyzing power is near its maximum. The results confirmed that the two so-called ``unpolarized states`` of the source were polarized to several percent, whereas the absolute values of the beam polarizations in the so-called ``polarized states`` were equal and opposite. It was observed that the hexapole lens of the ion source produced beam polarization in the absence of any ...
L_#alpha#/L_l X-ray intensity ratios have been measured in elements Ta, W, Au, Hg, Tl, Pb, Bi, Th and U using L-shell photoionization by 60 keV photons. The present results are found to agree with the calculated values of Scofield within experimental uncertainties. (author).
The article surveys studies into the global warming which have found that the OECD countries are responsible for less than half of the total registered warming. Calculation and analysis methods for estimating the global contributions from the blocks of OECD, Africa/America/Middle East, Asia and former Soviet Union/Eastern Europe are presented. The results and some pollution abatement measures are discussed.
The water and steam circuits of steam generators in pressurized-water nuclear power plants are described together with the mechanism of denting, and the corrosion of spacer plates that leads to cracks in tubes by constriction. The different chemical specifications applicable to the water of the secondary circuit of the generators in normal operation and on first commissioning are listed. The results obtained and the measurements of chemical values taken in operation on the water in the secondary circuits of steam generators at Fessenheim and Bugey are presented.
The water and steam circuits of steam generators in pressurized-water nuclear power plants are described together with the mechanism of denting, and the corrosion of spacer plates that leads to cracks in tubes by constriction. The different chemical specifications applicable to the water of the secondary circuit of the generators in normal operation and on first commissioning are listed. The results obtained and the measurements of chemical values taken in operation on the water in the secondary circuits of steam generators at Fessenheim and Bugey are presented.
A series of real-time, neutron radiography, experiments are ongoing at the Texas A and M Nuclear Science Center Reactor (NSCR). These tests determine the resolving capabilities for radiographic imaging of two phase water and air flow regimes through small diameter flow channels. Though both film and video radiographic imaging is available, the real-time video imaging was selected to capture the dynamic flow patterns with results that continue to improve. (author)
The nuclear shapes of transitional Mo isotopes are calculated by means of a model based on the cranking approximation and the Strutinksy method. The recent experimental results of the high-spin spectroscopy and lifetime measurement of [sup 87]Mo are studied in detail and explained by the evolution of the [gamma]-deformation with the quasiparticle configurations. The shape calculations with the modified-harmonic-oscillator potential give a critical neutron number N [>=] 47 for the spherical shape of the Mo isotopes. (orig.)
The nuclear shapes of transitional Mo isotopes are calculated by means of a model based on the cranking approximation and the Strutinksy method. The recent experimental results of the high-spin spectroscopy and lifetime measurement of "8"7Mo are studied in detail and explained by the evolution of the #gamma#-deformation with the quasiparticle configurations. The shape calculations with the modified-harmonic-oscillator potential give a critical neutron number N #>=# 47 for the spherical shape of the Mo isotopes. (orig.).
In this work, the thermodynamic behaviour of single-stage horizontal spray coolers with one or more spray levels is experimentally examined. Further, a spray cooler calculation model was developed, in order to describe the processes and to make a comparison of the results of calculation and measurement. The state of the mine climate and the cold water are taken as the thermodynamic reference. (orig.).
This book explores the development, present, and future applications of proton microprobes in the micrometer range. Among the topics discussed: the use of proton beams for analytical purposes; techniques of focusing or collimating ion beams; improving and measuring beam spots; the analytical capabilities of the nuclear microprobe in comparison to other micro techniques; and applications and results by several internationally known microprobe laboratories.
The electron-phonon coupling constant lambda has been calculated for vanadium. The electron energy bands and wave functions were obtained from a model augmented plane wave muffin-tin potential. The electron-phonon matrix elements were evaluated using the rigid-ion approximation and the measured phonon spectra. The results show that lambda is strongly affected by d-f scattering.
A community health survey of 438 individuals was taken to detect health problems related to high voltage electrical transmission among an adjacent residential population. Results revealed no significant or consistent relationships between exposure to a high voltage DC power line and the perceived health problems that were measured. The sample was not, however, large enough to draw statistically significant conclusions regarding possible health effects with a very low incidence.
The concept of the modern data acquisition system and some functional specialties of the programming software--Visual Basic 6.0 are introduced. The construction and theory of the hardware and the designing principle of the software are described. Experimental results showed that the real-time data acquisition rate was as high as 10 times per second in the system. And the relative standard uncertainty of the measurement was less than 0.5%. (authors)
The behaviour of an elastomeric seal for vehicle brake Tandem master cylinder is measured and analyzed in temperature and brake fluids changed. Working conditions are simulated for different piston rod velocity and cylinder supply pressure, in temperature rising, brakefluid boundary and Nanoaluminum oxide brakefluid oxide brakefluid lubrication. The result shows that Nanoaluminum oxide brakefluid with its ball shape can highly reduce friction coefficient to avoid seal excessive wear and reduce slick slip in brake applications.
Radicals formed in gamma-irradiated crystals of galactose and glycine were found, upon dissolution, to cause mutagenesis of Salmonella typhimurium strains TA-98 and TA-100. Although the reproducibility of the results has not been adequately determined, they suggest the possibility of developing a test to measure the mutagenic-carcinogenic potential of radiation-induced free radicals with a microbial system.
The paper reviews the formation of minor actinides in light water and fast reactors, as well as the current status and recent improvements in the nuclear data for minor actinides, and compares recently evaluated data with experimental results. The paper also describes the qualification of nuclear data by post-irradiation analysis and integral measurements in fast critical assemblies. (author).
Structural relaxation, crystallization and optimisation processes in soft magnetic amorphous alloys based on iron are examined by applying different experimental techniques: X-ray diffraction analysis, high-resolution electron microscopy, measurements of magnetic and electric properties (permeability, after-effect resistivity). The presented results are discussed in terms of annealing out of microvoids, formation of nanocrystalline phase and changes of effective magnetostriction constant. (author)
The results of photoneutron spectra measurements for the reaction (#gamma#,n) on the Sr-88 nuclei near threshold are presented. The parameters of resonance levels, as well as radiative S_#gamma#"("1") and neutron S_n"("1") strength functions for transitions on the first excited level of Sr-87 were obtained. 2 refs.; 1 fig.; 1 tab.
When steam generator tube denting was identified, steps were taken to retard the rate of corrosion and to develop corrective measures if possible. Techniques were developed to determine the exact shapes of the tubes, and procedures were devised to analyze resulting strain and operating stresses. Tube plugging criteria were established, and in twelve years of operation, there has been only one instance of a forced outage due to a tube leak.
Azobenzene dyes are effective inhibitors for austenitic 304 L and 316 L stainless steel corrosion in high acidic medium up to 7N. A good efficiency is obtained from weight loss and electrochemical Rsub(p) measurements in hydrochloric acid, while no inhibition is observed in sulfuric solutions. Transformation from the primarily azobenzene to other compounds give rise to enhanced protection of steel samples, and probable structures of the inhibiting species are proposed in view of our results.
Azobenzene dyes are effective inhibitors for austenitic 304 L and 316 L stainless steel corrosion in high acidic medium up to 7N. A good efficiency is obtained from weight loss and electrochemical Rsub(p) measurements in hydrochloric acid, while no inhibition is observed in sulfuric solutions. Transformation from the primarily azobenzene to other compounds give rise to enhanced protection of steel samples, and probable structures of the inhibiting species are proposed in view of our results.
Halide complexes of astatine cations At"+ and AtO"+ were prepared and their rate of migration was measured. The complexes are of the type AtX_2"- and AtOX_2"- (X = Cl"-, Br"-, I"-). The bromo complexes, AtBr_2"- and AtOBr_2"-, have a higher stability than the chloro complexes. The hydrolysis in weakly alkaline solution of AtX_2"- resulted At"-, and that of AtOX_2"- AtO_2"-. (author).
Possibility for using a sodium iodide scintillator as a reference signal source is considered. Experimental data on studying the performance of a gamma thickness gage with an additional scintillator are given. Results of experimental investigations of a thickness gage dummy proved practical expediency of the principle being considered. It is established, in particular, that the device is ready to operate without warm-up with a constant sensitivity, the deviation not exceeding 0.5%, in the ambient temperature range of 15-25 deg C.
Recent developments in design and production of thermal neutron detectors based on a crystalline Si diode coupled to a Gd converter are reviewed. The most significant results of neutron test measurements carried out on prototype systems and pointing out the performances of the device are reported. Progress through various detection schemes and technological solutions for the production of a real time neutron counter for routine operation are outlined.
This rebuttal to a previous article provides new insight into the use of sprayed sealants in uranium mines. The author rejects the idea that the value of rock sealant on radon control is destroyed by changes in barometric pressure, showing that this is not necessarily true. The analyses described demonstrate that radon contamination resulting from changing barometric pressures is reduced by a rock coating. The overall use of coatings depends on their costs and effectiveness as compared with other radon control measures. 6 refs.
A micro-computer based fuzzy logic power system stabilizer is applied to a micro-machine system to investigate its efficiency in real time control. The stabilizing signal is determined by using measured speed or real power signals at every sampling time to damp the system oscillations. The results show the proposed stabilizer improves the system damping effectively subject to various types of disturbances.
The purpose of the work reported in this paper was to measure the radionuclide buildup in primary heat transport system cell No. 3 at the Fast Flux Test Facility (FFTF) and to compare the results with predicted values from a model based on experimental studies and experience at similar reactors. The information obtained is used for maintenance planning and to enhance ability to assess radionuclide buildup in the future at FFTF and in other reactors.
The feasibility was studied of the application of radionuclide X-ray fluorescence analysis to the identification and determination of chemical elements in the air. A description of the method is presented, the main stages of the analysis are discussed (sample preparation and standards, selection of radioactive radiation sources, geometry of measurement and evaluation of results). The method is illustrated on the determination of elements Fe, Cu, Zn, Br, and Pb in air samples taken in the city of Prague. (author) 2 tabs., 2 figs., 14 refs.
The radiation dose to a series of adult and paediatric patients undergoing cardiac catheterisations and adults having percutaneous transluminal coronary angioplasty has been measured/determined directly using lithium fluoride thermoluminescent dosemeters and indirectly using an air ionisation chamber which indicated exposure-area product. Somatic and genetic risks are estimated from the dosimetry results. It is suggested that the magnitude of the radiation hazard is negligible compared with other clinical hazards associated with these procedures. (author).
The fission gas xenon bonded in bubbles, in pore, and in the lattice of mixed carbide fuels is measured by electron-probe microanalysis. Radial xenon distribution and release curves are determined and are calibrated by gas chromatography of the bonded fission gas and by burnup analysis in the respective pin sections of the irradiation experiments FR2 6A and 6C, Mol 11/K 2, and DFR 330/1. The results are correlated to the microstructure of the fuel, bonding medium, temperature, and burnup. (Auth.).
Substantial changes in the radial distribution function of amorphous Si films have been observed in neutron-diffraction studies. The spectra indicate changes in short-range order associated with an approx.11% modification in the bond-angle distribution width. The results allow the first direct comparison of structural and vibrational Raman probes of variations in local order in thin-film amorphous solids. Good agreement is obtained between the measured bond-angle variation and that based on Raman estimates.
The magnetic #beta#-spectrometer of the #pi# #sq root#2 type with 0.07% pulse resolution is used to measure the intensities of interval conversion electrons on L- and M-subshells of 70.45 keV "1"7"7 Ta gamma-transition. The results are analyzed and the values of mixing parameter #sigma#(E2/M1) and penetration parameter #lambda# are obtained.
The optical properties of uranium monochalcogenides and monopnictides are discussed in terms of their electronic structure. A comparison is made with corresponding rare earth compounds. It is shown that there are close similarities to mixed valence CeN. the results support the occurrence of a dip in the density of d states near Esub(F), where the f density of states has its maximum. Empirical energy level schemes are derived which are found to agree with the existing information from XPS measurements and recent theories. (orig.).
It is shown that de-noising a measured time signal by wavelet technique produces a rather good result in time domain, while it has unwanted consequences in spectrum estimation. Therefore it can be used for reconstruction of the picture of the physical process, but it should be avoided, when the aim is to reveal eigenfrequencies or transient behaviour of the spectra.
Peculiarities of design of the PGV-1000 horizontal steam generator affecting soluble impurity distribution in its water volume are considered in brief. The results of estimating sodium distribution in different zones of the steam generator are presented. The conclusion is made on the necessity of arrangement of representative measurements of sodium and chloride content in water volume of the steam generator, particularly, in the hot bottom zone for optimization of blow-through flowsheet and its regulations.
Nuclear magnetic resonance results are presented for a number of NaCl-type compounds and cubic Laves-phase type compounds of uranium, neptunium, and plutonium. Special emphasis is placed on the Knight shift and spin-lattice relaxation time measurements and their interpretation in terms of localized or itinerant pictures of the 5f electrons. (author).
Nuclear magnetic resonance results are presented for a number of NaCl-type compounds and cubic Laves-phase type compounds of uranium, neptunium, and plutonium. Special emphasis is placed on the Knight shift and spin-lattice relaxation time measurements and their interpretation in terms of localized or itinerant pictures of the 5Line integral electrons.
Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).
Results of calculation of steady thermal-hydraulic characteristics of PVG-440 horizontal steam generator are presented. Steam flows in selected sections are compared to data provided by OKB Gidropress Calculated vapor void fractions are compared to measured ones. (orig.) (3 refs., 3 figs., 8 tabs.).
Results of calculation of steady thermal-hydraulic characteristics of PVG-440 horizontal steam generator are presented. Steam flows in selected sections are compared to data provided by OKB Gidropress Calculated vapor void fractions are compared to measured ones. (orig.) (3 refs., 3 figs., 8 tabs.).
This work presents and describes the natural radioactive occurrence in oil facilities. The origins of the detected radioactivity and the reasons of its settlement are discussed. The measurementsresults carried out in oil facilities in the Neuquina basin (Argentine) are shown in this work. The aim is to describe the actual situation and to evaluate the magnitude of the problem. Finally, recommendations are proposed to protect the health of the workers, especially of those who carry out the cleaning of the equipment, and to guarantee an appropriate final disposal for the generated radioactive residuals. (author)
The "1"3"1I-labelled monoclonal antibodies 791T/36 and 79IT/36 Fab fragments have been evaluated in the imaging of patients with colorectal cancer, with benign colorectal tumours, and with malignant tumours of other parts of the gastrointestinal tract. The results of clinical imaging have been carefully correlated with clinical findings and direct measurement of the preferential uptake of antibody by the tumours. (UK).
Due to their good hydraulic characteristic semi-axial pump turbines are used in the medium head range of pumped storage plants. This paper describes model tests performed on a semiaxial pump turbine model and shows the results of these tests. The aim of the model tests was the optimization of the hydraulic water passage, the measurement of the hydraulic characteristics over the whole operating range, the investigation of the cavitation behaviour, the investigation of the hydraulic forces and torques as well as the proof of the values guaranteed to the customer.
The mass-energy spectra of the fragments of thermal fission of {sup 242m}Am are measured using the time-of-flight technique. The resulting mass-yield curve and peak-to-valley ratio agree with radiochemical data. The parameters of the kinetic energy distribution of the fragments are determined for the first time. Data on the fine structure of mass spectra in the region of cold fragmentation are presented. 15 refs., 4 figs.
A general account of the properties, growing technology and annealing of lead-tin-telluride single crystals is given. Photoconductors were made for the 8 to 14 micron. spectral range and responsivity, detectivity and spectral response measurements showed satisfactory results. Improvement in the growing and annealing of the single crystals promise good performance in the near future.
Substantial damages at main components of steam turbines do not have to result inevitably in an exchange of the components concerned. Rather a preliminary or final repair is possible which also considers the cause of the damage. An important condition with the technically complex questions is an appropriate qualification and experience of all involved persons. The common task of operators, manufacturers and insurance companies is to preserve the balance from costs, expenditure of time and risk.
The macroscopic behavior of magnetostrictive materials results from domain evolutions occurring at a microscopic scale. The author shows how to compute magnetization and magnetostriction curves by appraising the behavior of the underlying microstructures. The method hinges on an averaging device (Young measures), which allows one to pass from the microscopic to the macroscopic scale. He takes into account the kinematical constraints on the accommodation of elastic effects, and he highlights the role of material symmetry in the selection of energetically optimal microstructures.
Heterodyne detection with a point-contact Josephson junction has been investigated both experimentally and theoretically. The measured performance of the device at 36 GHz is in good agreement with the theory. By operating vanadium point contacts at 1.4 K, the authors have achieved a single-sideband (SSB) mixer noise temperature of 54 K with a conversion gain of 1.35 and a signal bandwidth on the order of 1 GHz. A potentially impressive performance for these devices at submillimeter wavelengths can be extrapolated from the results.
Ksub(#beta#)/Ksub(#alpha#) X-ray intensity ratios have been measured for various elements between Z = 29 and Z = 79 for incident proton energies of 23.6, 32.1 and 43.6 MeV. The results yield no evidence for a variation in ratio with particle energy. (orig.).
The exafs method is proposed as a more informative, universal one to investigate the radiation defects in solids. The successful results as obtained by the author using the synchrotron radiation source are reported for the first time. The measurements were carried out in GaAsP crystals irradiated with 50 MeV electrons.
Energy spectra of the Bragg reflection of the Moessbauer ..gamma..-radiation from the /sup 57/Fe/sub 3/BO/sub 6/ weakly ferromagnetic monocrystal are studied. A strong effect of the interference transitions in iron nuclei, being in non-equivalent positions, on the spectra form is revealed. The measurementresults are compared with theoretical calculations.
The evaluated data testing for Si, Zr, Nb and Fe materials has been performed through the analyses of the neutron leakage spectrum from spherical assemblies measured in integral benchmark experiments with (d,t) and Cf fission neutron sources. Intercomparisons of the calculated from BROND-2, ENDF/B-6 and JENDL-3 data files with experimental results are presented.
The high-power model of Disk-and Washer (DAW) cavity for electron acceleration is under fabrication. Basic Dimensions of the cavity were determined from aluminum model measurement and electromagnetic field calculation. We have fabricated model made of OFC (Oxygen Free Copper) five times in total. Some details are optimized and corrected, and then the final brazing are proceeding. These model results and present status are described. (author)
A case report of falsely elevated serum hormone values measured by radio-immunoassay (RIA) is described. The radio-immunoassays concerned have a first antibody raised in rabbits and mostly a separation technique based on a second antibody-solid phase system. The presence of heterophyle (anti-rabbit) antibodies in patients' serum is proved.
The paper presents results of studies on the effect of heat treatment on strength and pattern of 40Kh steel impact failure. Loading levels corresponding to macroscopic spalling microdamage initiation in the material are determined for three initial states. Metallographic study on the spalling failure pattern for 40Kh steel in different initial states and data on microhardness measurement are presented.
Focused ion beam (FIB) repair of chromium defects on photomasks and reticles leaves a post repair stain in the quartz substrate. The wavelength dependent absorption properties of typical stained regions have been measured, showing transition losses up to 80% in the deep uv. A simple model is in good qualitative agreement with the experimental results. (author).
The results of Sandia National Laboratories' participation in the NASA Planetary Definition and Design Program are summarized. Areas reported include the characterization of large area cadmium zinc telluride spectrometers and the application of simulation techniques to the prediction of device performance. Also investigated was the response of mercuric iodide devices in the region from 1 to 100 KeV. A literature study to determine the status or radiation damage measurements in room temperature semiconductor devices is also reported.
Predictions and measurements of a multimode waveguide interferometer operating in a fibre coupled, ``dual-mode'' regime are reported. With a 1.32 micrometer source, a complete switching cycle of the output beam is produced by a 10.0 nanometer incremental change in the 8.0 micrometer width of the hollow planar mirror waveguide. This equates to a fringe spacing of $\\sim\\lambda /130$. This is an order of magnitude smaller than previously reported results for this form of interferometer.
The radiative decay K->mu nu gamma has been studied at ISTRA+ setup in a new kinematical region. About 46K events of K->mu nu gamma have been observed. The sign and value of Fv-Fa have been measured for the first time. The result is Fv-Fa=0.16(4)(5).
An investigation of natural convection losses from cavity-type solar central receivers is described and results are given. The approach followed was that of a fundamental experimental study in a simple cavity subject to well controlled boundary conditions. The Laser Doppler Velocimeter proved to be a useful technique to measure the velocity profiles associated with natural convection. Visualization techniques provided an understanding of the general behavior of the flow, particularly in three dimensional experiments. Experiments on systems of high Rayleigh numbers are described. (LEW)
Load-deflection characteristics of alumina and alumino-silicate fibrous blankets were experimentally determined. Load retention and springback capability of combinations of these materials were measured in a 10,000-hour test at surface temperatures of 650 to 1000"0C (1200 to 1832"0F). Experimental results are presented and future testing plans are discussed.
Radiation degradation of polycarbonate (PC) and polybutylene terephthalate (PBT) used as cable connector was evaluated using DSC, TGA, and mechanical properties. Glass transition temperature, melting temperature, 5% weight loss temperature, elongation at break, and tensile strength measurements were carried out for each of {gamma}-ray irradiated samples. In the results of those analyses, PC has radiation resistance better than PBT as a cable connector material.
Families of regimes for discrete control systems are studied possessing a special quasi-controllability property that is similar to the Kalman controllability property. A new approach is proposed to estimate the amplitudes of transient regimes in quasi-controllable systems. Its essence is in obtaining of constructive a priori bounds for degree of overshooting in terms of the quasi-controllability measure. The results are applicable for analysis of transients, classical absolute stability problem and, especially, for stability problem for desynchronized (asynchronous, switching) systems.
Ratio of the fissile isomers and prompt fissions yields has been measured in processes of neutron capture by /sup 241/Am and /sup 243/Am nuclei in the neutron energy interval from 0.2 up to 1.3 MeV. The present data and the previous results suggest that the fission Am isomers are spin structure isomers rather than shape isomers.
This document describes measurements of the directional spectral emittance of four ceramic mold materials. The work was performed with the samples at {approximately} 900{degree}C in a vacuum vessel pumped to {approximately}3 {times} 10{sup {minus}6}Torr. Results conform to expectations derived from prior work done with similar samples.
Results are presented from analyzing indicators for efficient operation of the fleet of production equipment under conditions of the ''Tsentral'naya'' mine of the production association ''Krasnoarmeyskugol'.'' Measures are presented which make it possible to increase the operating efficiency with minimum adjusted outlays.
Results from scanning electron microscopy, Fourier transform infrared spectroscopy and the measurement of thermally stimulated current show that a high density of the physical defects and the chemical defects are introduced into the surface of the silicone rubber plates after they are treated by corona discharge plasma. These defects behave electrically as shallow electron traps, leading to the formation of a uniform discharge in air at higher pressure when the corona-modified silicone rubber is used in dielectric barrier discharge.
Magnesium alloys and composites are potentially highly attractive materials for lightweight design in the automotive industry - if common forming technologies, i.e., deep drawing and cold extrusion, are applicable to them; so far, this is seldom the case. The authors have tested some candidate Mg alloys and discuss the results of their measurements in detail. The Figure shows a typical workpiece part obtained by a deep-drawing technique. (Abstract Copyright [2003], Wiley Periodicals, Inc.)
A multiwire cylindrical drift chamber is the main detector of the AMPIR 4#pi#-spectrometer for studying pion-nucleon reactions. The chamber has possibility to measure three coordinates by the electron drift time and by the charge division method. Chamber design and geometry, test bench, readout electronics and also results of calculations, simulation and tests are described.
In the Arabian Gulf region in general, and in Saudi Arabia in particular, demand for water in the agricultural, domestic, and industrial sectors has increased dramatically as a result of rapid development, and improved standard of living, and diversification of economic activity in agriculture and industry. This article presents an overview of supply and demand situations prevailing in the Arabian Gulf region and discusses various conventional and unconventional alternatives for meeting the growing demand for water. It also describes conservation measures and their socioeconomic effects.
Low power wire activations are being performed in the Oak Ridge Research Reactor (ORR) as part of the whole-core LEU demonstration experiments. Calculations of the demonstration cores, including simulation of the wire activations, are being performed at Argonne National Laboratory (ANL). This paper presents the results of comparisons for 293 wires from five cores and shows that, on the average, the integrated activities agree within 6%.
The biological activity of coir fibre, coir ash and their components were investigated in vitro by measuring the haemolytic activity and macrophage cytotoxicity. In vivo studies carried out by injecting guinea pigs intratracheally with coir fibres resulted in resolving granulomas. The observed haemolytic activity and macrophage cytotoxicity was more marked with coir ash compared with coir fibres. Chemical analysis of coir ash revealed the presence of toxic chemical constituents in appreciable amounts. PMID:6283694
Specifications of the PGV-1000 steam generators applied at the WWER-1000 NPP power units, operational experience and data on damages at the 'cold' heat carriers of steam generators are considered and their results are presented. Developed and introduced measures aimed at improving reliability and operational life of the PGV-1000 collectors are described.
Independent calculations of the antiproton-to-proton ratio by Gaisser and Maurer and by Badhwar et al. have produced conflicting results which obscure the interpretation of recent measurements of cosmic ray antiprotons. A detailed reexamination of these calculations has been performed and these differences have been resolved. We find that the first calculation was essentially correct and the reported fluxes of antiprotons are significantly higher than expected for secondary antiprotons in conventional models of cosmic ray propagation, as indicated by other recent calculations.
The resulting emissions of the firing of ceramic products of all type are described, the factors are enumerated to diminish the emissions in the kilns and the technologies applied in the kilns to reduce these emissions while carrying out energy saving are described briefly. (author)
In the last issue of 'L'Industrie ceramique et verriere', we presented the first part of this study. We describe in this issue the experimental procedure, the results and the conclusions of this work. (authors)
Sputter-removal rates of overlayer and interfacial species on silicon are analyzed to determine sputtering yields for the species involved. Sputtering yields up to two orders of magnitude lower than those measured for silicon are found, and the results are interpreted in terms of a cascade mixing process which continually reburies much of the overlayer material beyond the escape depth of the sputtered atoms.
Sputter-removal rates of overlayer and interfacial species on silicon are analyzed to determine sputtering yields for the species involved. Sputtering yields up to two orders of magnitude lower than those measured for silicon are found, and the results are interpreted in terms of a cascade mixing process which continually reburies much of the overlayer material beyond the escape depth of the sputtered atoms.
Experimental results of ageing effects in proportional counters are presented. The measurements were carried out for 158 ZEUS-BAC gas system monitoring counters. Deterioration of the pulse height distribution in azimuth and along the anode wire are presented. The influence of water admixture on counting gas is also described. (orig.).
This paper presents the history and objectives of the development of a standard method for the measurement of organic contaminants in biomass producer gases. Recently, a project with that title has started in the European 5{sup th} Framework Programme. The structure of this project with acronym 'Tar Protocol' is also described in this paper. The project is performed by 17 partners and continues earlier work initiated by IEA (International Energy Agency), DoE (Department of Energy) and EU (European Union) in 1998. The project aims to combine two draft Protocols that resulted from this earlier work. The Tar Protocol will be developed for accurate measurement of organic contaminants ('tars') over a large range of concentrations (1 mg/Nm{sup 3} to 100 g/Nm{sup 3}) and conditions (0 - 900 deg C; 0.9 - 60 bars). Besides, a particulate concentration will be determined too. Together with the ...
A review of the status of integral measurements is presented for "2"4"0Pu, "2"4"1Pu, "2"4"2Pu, "2"4"1Am and "2"4"3Am. This review includes integral measurements pertinent to thermal reactor systems, i.e., thermal cross sections and resonance integrals, as well as measurements for fast reactor systems. It appears that for these nuclides the data for thermal reactors are in good shape; however, more work is recommended in defining the branching ratio of the capture cross section of "2"4"1Am to the isomeric and ground states of "2"4"2Am. Also, benchmark irradiation data are needed for cross section data testing using depletion/production codes. For fast reactors, experiments are in progress, in the UK, in France, and also in the US, with partial results available at this time. Fast integral data obtained from these measurements will be very beneficial. The recommendation pertaining to ...
Inhalation of radon and its daughter products makes the major contribution to the total exposure of the population to natural radiations. In implementing a complex ecological survey, concentrations of radon and its daughter products were measured in different regions of Russia, namely, in the St. Petersburg Region, the Central Territories and the Altay Territory. Two suitable low price versions of the dosemeters for measuring environmental radon concentrations based on track-etch and activated-charcoal detectors were used. The radon daughter product activity and the effective dose equivalents were calculated with an equilibrium factor of 0.5 and a recommended effective dose equivalent factor of 0.061 mSv (Bq m{sup -3}){sup -1}. Indoor measurements were taken in more than 1000 dwellings and public and industrial buildings of 21 towns and villages. The track chambers were exposed for about 2-3 months and the charcoal ...
Inhalation of radon and its daughter products makes the major contribution to the total exposure of the population to natural radiations. In implementing a complex ecological survey, concentrations of radon and its daughter products were measured in different regions of Russia, namely, in the St. Petersburg Region, the Central Territories and the Altay Territory. Two suitable low price versions of the dosemeters for measuring environmental radon concentrations based on track-etch and activated-charcoal detectors were used. The radon daughter product activity and the effective dose equivalents were calculated with an equilibrium factor of 0.5 and a recommended effective dose equivalent factor of 0.061 mSv (Bq m"-"3)"-"1. Indoor measurements were taken in more than 1000 dwellings and public and industrial buildings of 21 towns and villages. The track chambers were exposed for about 2-3 months and the charcoal detectors for ...
The state vector evolution in the interaction of initial measured pure state with collective quantum system or the field with a very large number of degrees of freedom N is analysed in a nonperturbative QED formalism. As the example the measurement of the electron final state scattered on nucleus or neutrino is considered.In the nonperturbative field theory the complete manifold of the system states is nonseparable i.e. is described by tensor product of infinitely many independent Hilbert spaces. The interaction of this system with the measured state can result in the final states which belong to different Hilbert spaces which corresponds to different values of some classical observables,i.e. spontaneous symmetry breaking occurs. Interference terms (IT) between such states in the measurement of any Hermitian observable are infinitely small and due to it the final pure states can't ...
The ratio of the proton's electric to magnetic form factor, G{sub E}/G{sub M}, can be extracted in elastic electron-proton scattering by measuring cross sections, beam-target asymmetry, or recoil polarization. Separate determinations of G{sub E}/G{sub M} by cross sections and recoil polarization observables disagree for Q{sup 2}>1 (GeV/c){sup 2}. Measurement by a third technique might uncover an unknown systematic error in either of the previous measurements. The beam-target asymmetry has been measured for elastic electron-proton scattering at Q{sup 2} = 1.51 (GeV/c){sup 2} for target spin orientation aligned perpendicular to the beam momentum direction. This is the largest Q{sup 2} at which G{sub E}/G{sub M} has been determined by a beam-target asymmetry experiment. The result, {mu}G{sub E}/G{sub M}=0.884{+-}0.027{+-}0.029, is compared to previous world data.
The presence of residual stresses in engineering components can significantly affect their load carrying capacity and resistance to fracture. In order to quantify their effect it is necessary to know their magnitude and distribution. Neutron diffraction is the most suitable method of obtaining these stresses non-destructively in the interior of components. In this paper the principles of the technique are described. A monochromatic beam of neutrons, or time of flight measurements, can be employed. In each case, components of strain are determined directly from changes in the lattice spacings between crystals. Residual stresses can then be calculated from these strains. The experimental procedures for making the measurements are described and precautions for achieving reliable results discussed. These include choice of crystal planes on which to make measurements, extent of masking needed to identify a ...
To dispose the radioactive waste drums, the waste form's integrity and the nuclides inventories must be assured according to the national and site waste acceptance criteria. Because they might be would gravely affected the performance objectives of disposal site. Our national regulation for the waste inventory related to 'Radioactive Waste Acceptance Criteria' requires that the activities of 13 nuclides and gross {alpha} must be measured and the 95 % of nuclides incorporated in the drum must be identified. It is very difficult to measure the radioactivity with accuracy from the regulated waste drum(200L), and have a large error in the analysis results. In present, there are two system, SGS (Segmented Gamma Scanning System) and TGS (Tomographic Gamma Scanning System) for the analysis of radionuclides from the waste drums. In general, it is known that the accuracy of TGS is below 20 % and that of ...
To dispose the radioactive waste drums, the waste form's integrity and the nuclides inventories must be assured according to the national and site waste acceptance criteria. Because they might be would gravely affected the performance objectives of disposal site. Our national regulation for the waste inventory related to 'Radioactive Waste Acceptance Criteria' requires that the activities of 13 nuclides and gross #alpha# must be measured and the 95 % of nuclides incorporated in the drum must be identified. It is very difficult to measure the radioactivity with accuracy from the regulated waste drum(200L), and have a large error in the analysis results. In present, there are two system, SGS (Segmented Gamma Scanning System) and TGS (Tomographic Gamma Scanning System) for the analysis of radionuclides from the waste drums. In general, it is known that the accuracy of TGS is below 20 % and that of SGS is below 30 %. The ...
A combination of measuring instruments, consisting of a Beta-Sedimeter and a radionuclide X-ray fluorescence instrument, is described. With the Beta-Sedimeter the C-14-radiation is measured. Through direct irradiation with photons of a Pu238-source in an ancillary irradiation chamber and energy dispersing measurement of the K- and L-radiation resp. of the excited heavy metals with the aid of a Si(Li)-semiconductor detector and a 4-channel analyzer the heavy metal concentrations of the heavy metals Zn, Cr, Ni and Pb are determined. For the determination of cadmium the indirect excitation with Am-241 and Dy-targets is described. The system produces records and operates fully automatically in a step-by-step mode with a testing cycle of 45 minutes. In connection with the process monitoring of the wastewater from a zinc plating plant during a period of 8 months the concentration of the solid material and of the metals Cr and Zn, ...
A measurement of the t{bar t} production cross section at {radical}s = 1.96 TeV in the dilepton final states using a lepton+track selection and secondary vertex b-tagging is presented. One of the two leptons from the decay of the t{bar t} pair is allowed to be identified only as an isolated track to improve the selection efficiency. The result is combined with a measurement in the t{bar t} {yields} e{mu} final state. The measurements are based on 370 pb{sup -1} of data collected with the D0 experiment at the Tevatron collider. The preliminary cross section obtained in the combined lepton+track and e{mu} channel is: {sigma}{sub t{bar t}} = 8.6{sub -1.7}{sup +1.9}(stat) {+-} 1.1(syst) {+-} 0.6(lumi) pb.
The electron affinities of indium and thallium were measured in separate experiments using the laser-photodetachment electron spectroscopy technique. The measurements were performed at the University of Nevada, Reno. Negative ion beams of both indium and thallium were extracted from a cesium-sputter negative ion source, and mass analyzed using a 90{sup o} bending magnet. The negative ion beam of interest was then crossed at 90{sup o} with a photon beam from a cw 25-Watt Ar{sup +} laser. The resulting photoelectrons were energy analyzed with a 160{sup o} spherical-sector spectrometer. The electron affinity of In({sup 2}P{sub 1/2}) was determined to be 0.404 {+-} 0.009 eV and the electron affinity of thallium was determined to be 0.377 {+-} 0.013 eV. The fine-structure splittings in the ground states of the negative ions were also determined. The experimental measurements will be compared to several ...
The effect of nutrition on reproductive performance was studied in a series of experiments using two models. Increased supply of nutrients was based on feeding lupin grain as a supplement and measurements of testicular growth or ovulation rates were used to measure reproductive characteristics. Purified sources of protein and energy were provided to determine the macronutrient(s), supplied with lupin feeding, responsible for initiating increases in testicular growth and ovulation rate. Increases in both of these parameters were closely related to the supply of additional energy but not protein. The production of acetate and glucose resulting from supplementary feeding with 750 g lupins/d was measured using infusions of "1"4C tracers. Subsequently, infusions of glucose and acetate (individually and in combination) were found to produce similar increases in ovulation rate to those ...
A new type of passive integrating cup monitors was developed to measure indoor thoron("2"2"0Rn) and radon("2"2"2Rn) concentrations. By placing a pair of cup monitors with different size a air exchange windows in the same place during a sufficient period of time the concentrations of both gases can be assessed from the alpha track densities on the CN films of the two monitors. The lower detection limit with a 3 months measurement period is for "2"2"0Rn 26.1 Bq*m"-"3 and is for "2"2"2Rn 6.1 Bq*m"-"3. Radon-220 and "2"2"2Rn concentrations have been measured in about 20 different types of dwellings around the Nagoya area with these monitors. The results suggest that the "2"2"0Rn concentrations were rather high in traditional Japanese dwellings made of a timber frame and mud. (orig.). (4 refs., 4 figs.).
For the first time absolute total cross sections for electron-impact excitation of a multiply-charged ion have been measured using an electron-energy-loss technique. Measurements were made near threshold for the process e + Si"3"+(3s"2S_1_/_2) #-># e+Si"3"+(3p"2P_1_/_2_,_3_/_2)-8.88 eV. The 10"-"1"5 cm"2 measured cross section agrees with results of 7-state close coupling calculations to better than the #+-#20% (90% CL) total uncertainty of the measurements. Convoluting the theoretical curve with a Gaussian energy distribution indicates an energy width of 0.15 < or approx. #DELTA#E < or approx. 0.20 eV. (orig.).
The sub-criticality monitoring system has been developed for criticality safety control in nuclear fuel handling plants. In the past experiments performed with the Deuterium Critical Assembly (DCA), it was confirmed that the detection of sub-criticality was possible to k{sub eff} = 0.3. To investigate the applicability of the method to more generalized system, experiments were performed in the light-water-moderated system of the modified DCA core. From these experiments, it was confirmed that the prompt decay constant ({alpha}), which was a index of the sub-criticality, was detected between k{sub eff} = 0.623 and k{sub eff} = 0.870 and the difference of 0.05 - 0.1{Delta}k could be distinguished. The {alpha} values were numerically calculated with 2D transport code TWODANT and monte carlo code KENO V.a, and the results were compared with the measured values. The differences between calculated and measured values were proved ...
This paper presents direct measurements of the aerodynamic forces on the wing of a free-flying, insect-like ornithopter that was modeled on a hawk moth (Manduca sexta). A micro differential pressure sensor was fabricated with micro electro mechanical systems (MEMS) technology and attached to the wing of the ornithopter. The sensor chip was less than 0.1% of the wing area. The mass of the sensor chip was 2.0 mg, which was less than 1% of the wing mass. Thus, the sensor was both small and light in comparison with the wing, resulting in a measurement system that had a minimal impact on the aerodynamics of the wing. With this sensor, the 'pressure coefficient' of the ornithopter wing was measured during both steady airflow and actual free flight. The maximum pressure coefficient observed for steady airflow conditions was 1.4 at an angle of attack of 30"0. In flapping flight, the coefficient was around 2.0 ...
The theory of a method of determination of reactivity from power spectral density measurements with /sup 252/Cf and the results of experiments with a critical assembly mockup of a liquid-metal fast breeder reactor (LMFBR) and with uranium (93.2 wt % /sup 235/U) metal cylinders and a sphere are presented. This method of reactivity determination has an advantage over existing methods in that it determines the reactivity only from properties of the reactor at the subcritical state of interest and thus does not require a calibration near delayed criticality. In these experiments, the reactivity was varied by changing the fissile loading or the amount of neutron absorber inserted; for the LMFBR mockup, the reactivity varied to approximately 75 dollars subcritical, and for the uranium metal assemblies to approximately 30 dollars subcritical. These experiments verified for the first time the predictions of theory that could be tested in the ...
A method that employs simultaneous neutron and #gamma#-ray diffraction techniques is proposed for accurate measurements of strains with or without an applied electric field (0-100 kV m"-"1). Instead of an absolute determination of the position of the neutron Bragg peak, a relative measurement of the neutron and #gamma# peak positions is used and allows a determination of the lattice-parameter changes with an accuracy of within 2 x 10"-"6. This technique avoids systematic errors originating in sample rotations by taking advantage of a reference directly related to the crystal lattice. The method appears to be particularly important for crystals that exhibit structural phase transitions, as demonstrated by the measurement of the strain U_x_x in KH_2PO_4 crystals as a function of temperature and applied electric field. In this case the errors would amount to #+-#20%. The results demonstrate the need to ...
Two measurement methods to determine the rate of neutral free radical production by the photo-deionization of negative ion beams (PDINIB) are introduced. These methods, namely, photoelectron-current measurement by low-frequency electro-modulation probe (PMMP) and measurement of decrease in the negative-ion beam current (DNIC) were employed to evaluate the production rate in a trial surface-processing apparatus developed in the author's laboratory utilizing a steady-flux refined beam of neutral free radicals (RBNR) produced by the PDINIB procedure. A {sup 63}Cu{sup -} negative ion beam of kinetic energy E{sub i} varied up to 15 keV was irradiated with a 514.5 nm visible light beam from a 25 W CW Ar{sup +} ion laser. The detection limit of the production rate by the PMMP setup was as high as 6 x 10{sup 9} s{sup -1} under the condition that E{sub i}=15 keV, the negative-ion beam current I{sub i}=4 {mu}A and the laser ...
A algorithm was developed to determine the characteristic parameters of PWR spent fuel, such as burnup, cooling time and initial enrichment of {sup 235}U by use of gamma-ray activity ratios of {sup 134}Cs/{sup 137}Cs, {sup 154}Eu/{sup 137}Cs and {sup 106}Ru/{sup 137}Cs from the high resolution gamma-ray spectroscopy and ORIGEN-S calculations. For the verification of the method developed, gamma-ray measurements of Kori-1 and Kori-2 nuclear fuel rods were carried out using HPGe gamma ray scanning system. As a results, it is revealed that the measured values are in a good agreement with the operator declared values within the about {+-} 5% errors. Besides, the under-water burnup measuring device has been designed to measure the gamma-ray from the PWR spent fuel assembly. This device will be set up in the pool of Post-Irradiation Examination Facility(PIEF), and used in determination of ...
We suggest and describe the use of a binary pseudo-random (BPR) grating as a standard test surface for measurement of the modulation transfer function (MTF) of interferometric microscopes. Knowledge of the MTF of a microscope is absolutely necessary to convert the measured height distribution of a surface undergoing metrology into an accurate power spectral density (PSD) distribution. For an'ideal' microscope with an MTF function independent of spatial frequency out to the Nyquist frequency of the detector array with zero response at higher spatial frequencies, a BPR grating would produce a flat 1D PSD spectrum, independent of spatial frequency. For a'real' instrument, the MTF is found as the square root of the ratio of the PSD spectrum measured with the BPR grating to the'ideal,' spatial frequency independent, PSD spectrum. We present the results from a ...
Safety studies related to the disposal of low- and intermediate waste indicate that the long term risk is determined by the presence of long-lived nuclides such as "1"4C, "5"9Ni, "6"3Ni, "9"9Tc, "1"2"9I and the transuranium elements. As most of these nuclides are difficult to measure, the correlation between these critical nuclides and some other easily measurable key nuclides such as "6"0Co and "1"3"7Cs has been investigated for typical waste streams of Paks Nuclear Power Plant (Hungary) and scaling factors have been proposed. An automated gamma-scanning monitor has been purchased and calibrated to determine the gamma-emitting radionuclides. Radiochemical methods have been developed to determine significant difficult-to-measure radionuclides. The radionuclides of interest have been "3H, "1"4C, "9"0Sr, "5"5Fe, "5"9Ni, "9"9Tc, "1"2"9I and TRUs. The measurements taken so far have revealed brand new ...