Transbrachial arterial digital subtraction angiography
International Nuclear Information System (INIS)
27 cases including 7 outpatients, underwent intraarterial DSA using 4-F nylon catheter, by transbrachial arterial approach. Much of DSAs were performed in Fuji Computed Radiography (FCR), which has high spatial resolution. In all cases, image quality satisfied clinical demands. No major complication occured in this series. Transbrachial arterial digital subtraction angiography is excellent and safe method for screening of vascular disease. (author).
1985-01-01
Energy Technology Data Exchange (ETDEWEB)
Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management.
1987-03-01
International Nuclear Information System (INIS)
Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management. (orig.).
1987-01-01
Clinical application of dual energy subtraction in direct digital radiography of chest
International Nuclear Information System (INIS)
Objective: To discuss the clinical application value of dual energy subtraction (DES) in direct digital radiography of chest. Methods: 83 cases of chest digital radiography(DR) using double-energy subtraction (DES) were randomly selected, and three posterior-anterior (PA) chest films (standard image, bone image and soft tissue image) were obtained in each case, which is so called 'bone and soft tissue separated' technology. Results: With the aid of double energy subtraction (DES), the bony chest was subtracted, the sensitivity and specificity of pulmonary calcification were improved, and sensitivity of pulmonary nodes was also improved, enhancing the distinction between pulmonary benign or malignant lesions, enlightening the diagnosis of chest cage lesions, and showing a clear superiority in the detection of pulmonary nodes comparing to common chest films. The ...
2009-02-01
Somatic and genetic radiation exposure of the patient in digital subtraction angiography (DSA)
International Nuclear Information System (INIS)
The somatic and genetic radiation exposure of patients undergoing Digital Subtraction Angiography (DSA) and traditional Film Arteriography (FA) of cranial, cervical, thoracic and abdominal vascular territories are compared. The radiation doses absorbed within the critical organs - red bone marrow, lung, thyroid gland and female breast - and in the gonads were measured using an anthropomorphic Alderson phantom. A Somatic Dose Index was calculated in order to estimate the somatic radiation risk. The somatic radiation exposure depends upon the location of the critical organs with respect to the entrance site of the x-ray beam, and can be reduced by an appropriate choice of the angiographic projection. Under this condition, the radiation exposure of the patient during DSA can be lower than during FA. For renal DSA an a.p. projection, the use of an abdominal compression device and careful caudal shielding of the field are advocated. (orig.).
1986-01-01
Need for New Optimisation Strategies in CR and Direct Digital Radiography
Energy Technology Data Exchange (ETDEWEB)
Digital imaging techniques such as Digital Image Intensifier Radiography and Digital Storage Phosphor (Selenium) Radiography are replacing conventional film-screen radiography more and more. The aim of this development is the extension of diagnostic capabilities and the reduction of side effects such as radiation dose. Conventional film-screen radiography and digital radiography are very different ways of imaging. For digital radiography specific post-processing is the link between imaging conditions and film documentation. Optimisation of the images includes new possibilities of post-processing and a broad range for variation of the dose. Especially in fluoroscopy, dose can be reduced significantly by new technical features like pulsed fluoroscopy. For digital radiography the European guidelines on quality criteria have to be applied to projection radiography, ...
2000-07-01
Need for New Optimisation Strategies in CR and Direct Digital Radiography
International Nuclear Information System (INIS)
Digital imaging techniques such as Digital Image Intensifier Radiography and Digital Storage Phosphor (Selenium) Radiography are replacing conventional film-screen radiography more and more. The aim of this development is the extension of diagnostic capabilities and the reduction of side effects such as radiation dose. Conventional film-screen radiography and digital radiography are very different ways of imaging. For digital radiography specific post-processing is the link between imaging conditions and film documentation. Optimisation of the images includes new possibilities of post-processing and a broad range for variation of the dose. Especially in fluoroscopy, dose can be reduced significantly by new technical features like pulsed fluoroscopy. For digital radiography the European guidelines on quality criteria have to be applied to projection radiography, ...
1999-06-13
Energy Technology Data Exchange (ETDEWEB)
The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one ...
2003-03-15
International Nuclear Information System (INIS)
The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one ...
2003-03-01
International Nuclear Information System (INIS)
Objective: To compare the efficiency of dual energy subtraction and conventional direct digital radiography in signal detecting ability. Methods: 200 plastic balls which were 4 mm in diameter were taken as signals and were placed on a 10 cm thick plastic board and the right upper thorax of a healthy volunteer. The signals were examined by DES and CDR separately and were estimated by 3 radiologists with 5-value-differentiation method. ROC curve analysis was made by ROC kit software. Results: when signals on plastic board were detected by CDR and DES, ROC curve analysis indicated that there was no significant difference (P=0.4851 > 0.05, two-tailed) between the area under the ROC curves of the two methods (Az=0.9931 for CDR and Az=0.9879 for DES). The difference was significant (P=0.0002 <0.01, two-tailed) between the area under the ROC curves of CDR and DES (Az=0.7276 for CDR and Az=0.8561 for DES), when the signals on the right upper ...
2005-06-01
Energy Technology Data Exchange (ETDEWEB)
In dual-energy projection radiography with double exposures, rapid energy switching is mandatory to eliminate motion artifacts, but it is costly for use in a clinical environment. We developed a system with practical exposure intervals at reasonable cost by modifying a condenser-type X-ray generator. A commercially available system for digital radiography (Fuji Computed Radiography, FCR) was used to subtract images. This report dealt with technical factors to obtain adequate kV and mAs settings in this technique.
1987-04-01
Dual-energy projection radiography using condenser discharge x-ray generator and FCR
International Nuclear Information System (INIS)
In dual-energy projection radiography with double exposures, rapid energy switching is mandatory to eliminate motion artifacts, but it is costly for use in a clinical environment. We developed a system with practical exposure intervals at reasonable cost by modifying a condenser-type X-ray generator. A commercially available system for digital radiography (Fuji Computed Radiography, FCR) was used to subtract images. This report dealt with technical factors to obtain adequate kV and mAs settings in this technique. (author).
1987-01-01
Application of digital radiography to diagnosis of laryngeal diseases
International Nuclear Information System (INIS)
Fuji Computed Radiography (FCR) is a new system of digital radiography that is based on the latest computer technologies. We applied this FCR system to the X-ray diagnosis of the laryngeal disease. Twenty patients with various laryngeal diseases were evaluated by both FCR frontal tomography and conventional screen-film frontal tomography under the same exposure condition. Both tomograms were then compared on the subject of the clarity of delineation of laryngeal structures. As the result, FCR tomograms revealed the feature of the laryngeal lumen and cartilages more clearly than conventional tomograms. In addition, energy subtraction method, which is one of FCR image processing systems, was presented as a new technical procedure to extinguish cervical spine shadows in plain anteroposterior laryngeal X-photograph. We stress that FCR system is the suitable procedure for X-ray analysis of laryngeal diseases, especially in the region related with ...
1986-01-01
Digital subtraction angiography with scanning lazer stimulated luminescence
International Nuclear Information System (INIS)
Fuji Computed Radiography (FCR) utilizes imaging plates of scanning lazer stimulated luminescence. FCR can be used for intravenous digital subtraction angiography (IVDSA) and for intraarterial studies because of tis high contrast and spatial resolution. Pixel size of the imaging plates for angiography is 0.2 mm. Experimentally, it could demonstrate a vessel 1 mm in diameter with a contrast of 0.1, when opacified with a contrast medium of 3 % iodine concentration, and could image a vessel 3 mm in diameter with contrast of 0.1, when opacified with 1 % contrast medium. A 20 % stenosed portion of a vessel 3 mm in diameter was identified when opacified with 3 % contrast medium, and a 20 % stenosed portion of a vessel 2 mm in diameter was identified when opacified with 10 % contrast medium. In 105 IVDSA examinations of 75 patients, FCR was superior to Digital Fluorography (DF) in spatial resolution, size of examination field, ...
1985-01-01
Eddy currents signal processing for steam generator inspection in PWR nuclear power plants
International Nuclear Information System (INIS)
Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostic system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of these items.
1992-01-01
Digital processing to improve image quality in real-time neutron radiography
Energy Technology Data Exchange (ETDEWEB)
Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction technique, and so on. For the real-time application a contouring operation and an averaging approach can also be utilized effectively.
1985-01-01
Digital processing to improve image quality in real-time neutron radiography
International Nuclear Information System (INIS)
Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction technique, and so on. For the real-time application a contouring operation and an averaging approach can also be utilized effectively. (orig.).
1985-01-01
Advanced readout integrated circuit signal processing
Readout integrated circuits (ROICs) for focal plane arrays (FPAs) have become increasingly complex to meet the needs of modern infrared systems. BAE Systems has pioneered a number of advanced signal processing architectures for FPA ROICs. Demonstrated signal processing capabilities of BAE Systems FPAs include analog-to-digital conversion, offset subtraction, individual pixel automatic gain compensation, transient noise suppression, on-FPA defect deselection, reconfigurable pixels, spatial neural network processing and subframe noise averaging. BAE Systems FPA advanced signal processing is not just for demonstrations, but is used in many of their deliverable FPAs, improving real system performance.
2006-06-01
International Nuclear Information System (INIS)
Ten patients with traumatic femoral neck fracture were studied with MR imaging (0.5 T, Magnetom, Siemens): unenhanced (multiecho, TR/TE = 1,600/30--240 [repetition time/echo time, msec]; gradient echo, TR/TE = 315/14, #theta# = 90 degrees) and Gd-DTPA enhanced (0.1 mM/kg body weight, Magnevist, Schering; gradient echo, TR/TE = 315/14, #theta# = 90 degrees). MR images were compared with clinical-radiographic findings. Digital subtraction angiography of the femoral head (FH) in five patients showed complete interruption of blood supply to the FH in three patients (signal intensity of FH did not increase on postcontrast images) and intact FH arteries in two patients (FH signal increased on postcontrast images, as did the healthy-side signal).
The Eighth Data Release of the Sloan Digital Sky Survey: First Data from SDSS-III
Energy Technology Data Exchange (ETDEWEB)
The Sloan Digital Sky Survey (SDSS) started a new phase in August 2008, with new instrumentation and new surveys focused on Galactic structure and chemical evolution, measurements of the baryon oscillation feature in the clustering of galaxies and the quasar Ly{alpha} forest, and a radial velocity search for planets around {approx}8000 stars. This paper describes the first data release of SDSS-III (and the eighth counting from the beginning of the SDSS). The release includes 5-band imaging of roughly 5200 deg{sup 2} in the Southern Galactic Cap, bringing the total footprint of the SDSS imaging to 14,555 deg{sup 2}, or over a third of the Celestial Sphere. All the imaging data have been reprocessed with an improved sky-subtraction algorithm and a final, self-consistent recalibration and flat-field determination. This release also includes all data from the second phase of the Sloan Extension for Galactic Understanding and Evolution (SEGUE-2), ...
2011-01-01
International Nuclear Information System (INIS)
The EXAFS-study (Fe, Sn and Ge K-edges) of disordered by mechanical activation binary supersaturated nanocrystalline solid solutions Fe-Al, Fe-Ge, Fe-Sn and Fe-Si is presented. The EXAFS-spectra are processed by solving the inverse binary problem, using the EXAFS-spectrum of the Fe K-edge only or combining the EXAFS-spectra on two K-edges, Fe and Ge or Fe and Sn. The parameters of partial correlation functions indicate chemical short-range ordering, high local static distortions in the lattice, increasing with metalloid content. The macrostructure of other type is forming through an initial, 'local' stage within the bcc lattice.
2007-05-21
Digital subtraction angiography (DSA) using Fuji computed radiography (FCR)
International Nuclear Information System (INIS)
A vessel phantom suitable for evaluation of spatial and contrast resolution of FCRDSA (Fuji Computed Radiography, digital subtraction angiography) has been developed and used for determining resolution. The effects of iodine concentration, low dose exposure, and acryl thickness on the resolution were evaluated in FCRDSA, and FCRDSA images were compared with film substraction with use of this phantom. It has been proven that limitation of resolution of FCRDSA was 5 % 1 mm and about 1/4 dose exposure compared with conventional film exposure was clinically acceptable. Dye dilution method was useful to determine a program of IVDSA with imaging plate. It has been proven that time to appearance and time to peak of time-concentration curve of dye dilution method closely correlate to time to appropriate image of DSA in the neck, the chest, and the abdomen. 106 cases of IVDSA and 130 cases of IADSA using FCR in Tohoku University Hospital from January ...
1984-12-01
Thallium-technetium subtraction parathyroid imaging in patients having previous parathyroid surgery
International Nuclear Information System (INIS)
Parathyroid imaging based on the principle of differential uptakes of Tc-99m and T1-201 in the anterior neck to localize parathyroid (PT) disease has been reported with widely varying results. To evaluate the usefulness of this method, we have performed PT imaging on 47 patients prior to exploratory surgery for PT disease. Using pinhole collimation and digital acquisition, a 50k count image of the thyroid was obtained 20 minutes after injection of 1mCi99m Tc-pertechnetate. Then a lmCi dose of Tl-201 chloride was injected and a series of images acquired for 30 minutes at 30 sec/image. Raw data was spatially filtered and normalized by summing sufficient T1-201 images to equal the Tc-99m image scale of maximum cts/pixel. Image subtraction (Tl-Tc) gave the final PT image. Of 10 pts who had previous neck exploration, all had PT pathology accurately localized by preoperative scanning (7=single adenoma, 2=single hyperplastic gland, 1=two hyperplastic ...
1985-06-02
FAQs for IIS Solicitation NSF-05551
... Science, Computer Vision, Digital Government, Digital Libraries, Digital Society and Technologies ... for Robust Intelligence, Digital Government, and Digital Libraries and Archives. In subsequent years ...
International Nuclear Information System (INIS)
Purpose. To evaluate injection-associated pain, safety, and efficacy with the isotonic contrast medium iodixanol (Visipaque 270 mg I/ml) compared with iopromide (Ultravist 300 mg I/ml) in femoral arteriography. Methods. A multicenter, double-blind, randomized, parallel-group clinical investigation was carried out in 54 hospitals in Europe. Of the patients evaluated, 1225 received iodixanol and 1227 iopromide in conventional and/or digital subtraction angiography. Results. The iodixanol group reported statistically significantly less injection-associated pain (0.9%) than the iopromide group (9.5%) (p<0.001). Further, 4.1% in the iodixanol group experienced pain and/or severe heat sensation vs 19.8% in the iopromide group (p<0.001). In the iodixanol group, 1.8% of the patients experienced contrast-related adverse events vs 2.4% in the iopromide group (p=NS). Overall diagnostic information was optimal for 94.1% in the iodixanol group and ...
1997-07-01
Energy Technology Data Exchange (ETDEWEB)
Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostics system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of these items.
1991-07-01
Energy Technology Data Exchange (ETDEWEB)
Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostic system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of these items.
1992-01-01
K-edge X-ray absorption spectra of argon in sputtered aluminum films
International Nuclear Information System (INIS)
We have measured K-edge X-ray absorption spectra of argon in sputtered aluminum films at a synchrotron radiation facility (the Photon Factory). We found that the energy and shape of white line change when the film is annealed at 500 C and the spectrum becomes resembling that of argon implanted in silicon. From the analyses of the X-ray absorption spectra and TEM observation we concluded that argon exists as very small atom clusters with a diameter less than 1 nm or exist as isolated atoms in the as-sputtered aluminum film, and that the size of the clusters become as big as 10 nm diameter when the film is heated. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)
1999-01-04
Tracheal images using energy subtraction Fuji computed radiography
International Nuclear Information System (INIS)
Twenty patients with lesions in the trachea or bronchus underwent energy subtraction Fuji computed radiography (FCR). Images obtained were compared with those from conventional FCR (plain FCR). ''Very clear'' images (in which the contour of the trachea and bronchus could be clearly defined) were obtained in 12/22 (55 %) by energy subtraction FCR and in 3/22 (14 %) by plain FCR; ''clear'' images (in which the contour could be defined) in 9/22 (41 %) by energy subtraction FCR and in 18/22 (82 %) by plain FCR; and ''unclear'' images (in which the contour could not be defined) in 1/22 (5 %) by both methods. Energy subtraction FCR, as well as plain FCR, yielded high image quality for the trachea. Energy subtraction FCR was superior to plain films when tumors existed within the trachea. (Namekawa, K.).
1985-01-01
DIGITAL LIBRARIES: IMPACT ON SCIENCE ... - MUSPIN - NASA
digital libraries, which was identified as a national challenge in the Information ... The linkages between the many digital libraries and information services are ...
The Design of an Interactive Online Help Desk in the Alexandria Digital Library
The Design of an Interactive Online Help Desk in the Alexandria Digital Library
1999-01-01
Resolution enhancement by subtraction of confocal signals taken at different pinhole sizes.
Subtractive imaging in confocal fluorescence light microscopy is based on the subtraction of a suitably weighted widefield image from a confocal image. An approximation to a widefield image can be obtained by detection with an opened confocal pinhole. The subtraction of images enhances the resolution in-plane as well as along the optic axis. Due to the linearity of the approach, the effect of subtractive imaging in Fourier-space corresponds to a reduction of low spatial frequency contributions leading to a relative enhancement of the high frequencies. Along the direction of the optic axis this also results in an improved sectioning. Image processing can achieve a similar effect. However, a 3D volume dataset must be acquired and processed, yielding a result essentially identical to subtractive imaging but superior in signal-to-noise ratio. The latter can be increased further with the ...
2003-01-01
International Nuclear Information System (INIS)
Purpose: Three-dimensional rotational angiography (3DRA) is a new technique based on a rotational angiographic acquisition able to display arterial vessels in a 3D rendering mode. The system was mainly developed for neuroradiological evaluations but preliminary extracranial experiences have also been reported. The aim of our work was to compare the results of three-dimensional angiography of the carotid arteries done with high-flow injection of contrast medium from the aortic arch with the results of selective angiography. Materials and methods: Twenty patients underwent digital angiography of the supra-aortic vessels in order to quantify a stenosis of the carotid bifurcations previously detected at Doppler Ultrasound. Examinations were performed with the Philips Integris Allura system provided with the rotational angiography (RA) tool connected to a workstation for three-dimensional reconstruction able to display vessels in a 3D fashion (Volume Rendering, Shaded ...
Energy Technology Data Exchange (ETDEWEB)
Hyaluronate (HA) distribution patterns were examined in the cranial mesenchyme underlying the mesencephalic neural folds of mouse embryos maintained in roller tube culture. Using standard image-processing techniques, the digitized images of Alcian blue-stained or 3H-glucosamine-labeled sections digested with an enzyme specific for HA, were subtracted from adjacent, undigested sections. The resultant difference picture images (DPI) accurately depicted the distribution of stained or labeled HA within the cranial mesenchyme. 3H-glucosamine-labeled HA was distributed uniformly throughout the cranial mesenchyme as 12, 18, and 24 hr of culture. By contrast, the mesenchyme was uniformly stained with Alcian blue at 12 hr, but stain intensity decreased in the central regions of the mesenchyme at 18 and 24 hr. HA distribution patterns were also examined in the cranial mesenchyme of embryos cultured in the presence of diazo-oxo-norleucine (DON), a ...
1990-06-01
Noninvasive follow-up of GDC-treated saccular aneurysms by MR angiography
International Nuclear Information System (INIS)
The aim of this study was to determine sensitivity and specificity of magnetic resonance angiography (MRA) for the assessment of durable occlusion of intracranial aneurysms with Guglielmi detachable coils (GDC) and to point out the influence of MRA results in re-intervention strategies. Forty-five patients with 54 aneurysms that were previously treated by endovascular occlusion with GDC were selected for this study. All patients underwent digital subtraction angiography (DSA) and MRA examinations on the same day. The time-of-flight MRA studies were performed on a 1-T scanner. The MRA images were first read by radiologists who were not aware of the DSA results. In a second consensus reading by the neuroradiologists who had performed all interventional procedures of this series, the decision was made as to whether re-treatment was necessary. The distribution of aneurysm sizes, configurations and treatment results were sufficient for an unbiased ...
2001-09-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film arteriogram even with a half concentration of ...
1989-06-01
International Nuclear Information System (INIS)
The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film arteriogram even with a half concentration of ...
1989-01-01
Energy Technology Data Exchange (ETDEWEB)
Hepatocellular carcinoma (HCC) is characterized by tumor vascularization from the hepatic artery. The objective of our work was to compare color Doppler ultrasonography (CDU), including power Doppler ultrasonography (PDU) with radiographic imagings with contrast medium in regard to the detection of the arterial tumor vascularity of small hepatocellular carcinomas (HCC). We examined 42 small HCC lesions 2 cm or less in diameter in 37 patients for arterial tumor vascularity by conventional CDU, PDU, dynamic computed tomography (dCT), digital subtraction angiography (DSA), and CT hepatic arteriography (CTA). Color images were detected in 25 (59.5%) and 28 (66.7%) of the 42 lesions with conventional CDU and PDU, respectively, and tumor vascularity was detected in 26 (61.9%) by dCT, 23 (54.8%) by DSA, and 29 (69.0%) by CTA. Tumor vascularity could be detected in 51.9% by PDU and CTA, more than by conventional CDU, dCT, and DSA (44.4, 44.4, and ...
2000-10-01
International Nuclear Information System (INIS)
The local environment of Ca dopants in barium titanate, BaTiO_3, is investigated by Ca K-edge X-ray absorption near-edge structure (XANES) spectroscopy. In conjunction with experiments, first-principles calculations by two methods are systematically made. The projector-augmented wave (PAW) method is used to optimize the local structure and obtain the formation energy. The augmented plane wave plus local orbitals method is adopted to obtain theoretical XANES spectra. A comparison between experimental and theoretical XANES spectra shows that Ca dopants are located at the Ba"2"+ sites forming Ca"2"+. Formation energy calculations of Ca doped BaTiO_3 by the PAW method also give the same results. The Ca atom in BaTiO_3 is off-centering in comparison with the Ba site in BaTiO_3. The off-centering of Ca atom is newly revealed by the combination of XANES spectroscopy and first-principles DFT calculations.
2010-06-01
We present an x-ray magnetic circular dichroism (XMCD) study performed on both Ho{sub 6}Fe{sub 23} and Y{sub 6}Fe{sub 23} compounds as a function of the temperature. The combined analysis of both Fe K-edge and Ho L{sub 2,3}-edge XMCD spectra recorded through the magnetic compensation transition allows us to disentangle the thermal dependence of both Fe and Ho magnetic moments in Ho{sub 6}Fe{sub 23}. In addition, contributions from Ho ions to the Fe K-edge XMCD signals and, conversely, from Fe ions to the Ho L{sub 2,3}-edge XMCD spectra have been clearly identified. These extra contributions, arising from the strong Fe(3d)-Ho(5d) hybridization, have been isolated from the spectra and correlated with the magnetic state of both Ho and Fe ions surrounding the absorbing site. The influence of these contributions to the values of the orbital and spin moments derived by using sum rule analysis is also shown.
2005-09-01
Asynchronous Digital Regulators
... (tb*it 06(M WfIio[td) Page 2. Asynchronous Digital Regulators Vernon Scott Ritchey, Ph.D. ... Page 3. ASYNCHRONOUS DIGITAL REGULATORS ...
2011-05-13
7.5 Minute Hypsography for Timber Knob, CA
(USGS Text) Digital line graph (DLG) data are digital representations of cartographic information. DLGs of map features are converted to digital form from ... ...
Interpretation of EXAFS data from laser shock compressed plasmas
Energy Technology Data Exchange (ETDEWEB)
Measurements on laser shock compressed aluminium using the EXAFS (Extended X-ray Absorption Fine Structure) technique on the Al K-edge are described. Two methods of analysis of this data were used for the determination of density: the standard EXAFS technique using Fourier transforms and curve fitting, and a method based on a bandstructure calculation of the absorption spectra as a function of compression. These two techniques give results which are in fairly good agreement with each other and also with a hydrodynamic simulation of the experiment. The ion correlation parameter is estimated and shows that two-sided laser irradiation of aluminium foils produces a dense plasma which is strongly coupled. (author).
1989-01-01
Annealing, lattice disorder and non-Fermi liquid behavior in UCu4Pd
Energy Technology Data Exchange (ETDEWEB)
The magnetic and electronic properties of non-Fermi liquid UCu{sub 4Pd} depend on annealing conditions. Local structural changes due to this annealing are reported from UL{sub III}- and Pd K-edge x-ray absorption fine-structure measurements. In particular, annealing decreases the fraction of Pd atoms on nominally Cu 16e sites and the U-Cu pair-distance distribution width. This study provides quantitative information on the amount of disorder in UCu{sub 4Pd} and allows an assessment of its possible importance to the observed non-Fermi liquid behavior.
2002-07-30
A computer-assisted method for 3D subtraction angiography based on spiral CT
International Nuclear Information System (INIS)
The objective of this study was to develop a method for 3D subtraction CT angiography and to optimize the visualization after semiautomatic segmentation. Ten patients with aneurysms of the abdominal aorta were examined using spiral CT. To reconstruct the vessels, as well as adjacent organs such as the liver and kidneys, one image data volume was acquired before and after injection of the contrast agent. The CT scans were obtained with a Siemens Somatom Plus 4. To improve the results of automatic segmentation, as well as visualization by maximum intensity projection (i.e. removal of bony structures), subtraction of both image volumes is necessary. However, small translation shifts disturb the subtraction process and produce artificial contours. To calculate the disparities along the three coordinate axes of two corresponding image volumes, a cepstrum filter is applied to a pair of image volumes. After detection of the ...
Net energy output from harvesting small-diameter trees using a ...
Sep 1, 2011 ... Description: What amount of extra energy can be generated after subtracting the total energy consumed to produce the biomass energy? ...
Intelligent Analyst Digital Video Library Prototype
... type. Sonic's digital libraries will provide a cross mapping between the narrative (speech and text) and imagery domains. ...
2002-10-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: To evaluate the success rates of the implantation of stent grafts in the treatment of peripheral aneurysms. Materials and methods: in 13 patients with 15 aneurysms at the common iliac artery (n = 6), external iliac artery (n = 1), hypogastric artery (n = 2), femoral artery (n = 2) or popliteal artery (n = 4), implantation of dacron-covered nitinol stents was performed. The patients were followed up for three to 20 months (mean, 8.8 months) with intravenous digital subtraction angiography, CT or colour-coded Doppler sonography. Results: In all cases, the aneurysm was successfully occluded after stent implantation. In one case with a popliteal aneurysm, kinking of the vessel caused thrombosis of the stent. The stent was successfully reopened. The aneurysm however, had to be surgically treated 9 months later. The primary and secondary patency rates at 6 months were 93% and 100%, respectively. Conclusion: The method described might be an ...
1998-03-01
The role of interventional radiology in management of patients with end-stage renal disease
Energy Technology Data Exchange (ETDEWEB)
The aim of the paper is to review the role of interventional radiology in the management of hemodialysis vascular access and complications in renal transplantation. The evaluation of patients with hemodialysis vascular access is complex. It includes the radiology/ultrasound (US) evaluation of the peripheral veins of the upper extremities with venous mapping and the evaluation of the central vein prior to the access placement and radiological detection and treatment of the stenosis and thrombosis in misfunctional dialysis fistulas. Preoperative screening enables the identification of a suitable vessel to create a hemodynamically-sound dialysis fistula. Clinical and radiological detection of the hemodynamically significant stenosis or occlusion demands fistulography and endovascular treatment. Endovascular prophylactic dilatation of stenosis greater than 50% with associated clinical abnormalities such as flow-rate reduction is warranted to prolong access patency. The technical success ...
2003-05-01
Digital Audio Sampling for Film and Video.
Digital audio sampling is explained, and some of its implications in digital sound applications are discussed. Digital sound equipment is rapidly replacing analog recording devices as the state-of-the-art in audio technology. The philosophy of digital recording involves doing away with the continuously variable analog waveforms and turning the patterns into numbers. A digital recording device rapidly samples the incoming sounds, quantifying the signal into a series of numerical values (binary codes). Although digital sound eliminates many of the traditional analog problems, digital signal processing presents key problems in sampling rates and synchronization. Careful control is necessary to check signals through each step in the audio chain. The advantages of digital audio processing include increased signal-to-noise ...
1993-03-01
Near-edge structures from first principles all-electron Bethe-Salpeter equation calculations
International Nuclear Information System (INIS)
We obtain x-ray absorption near-edge structures (XANES) by solving the equation of motion for the two-particle Green's function for the electron-hole pair, the Bethe-Salpeter equation (BSE), within the all-electron full-potential linearized augmented plane wave method (FPLAPW). The excited states are calculated for the Li K-edge in the insulating solids LiF, Li_2O and Li_2S, and absorption spectra are compared with independent particle results using the random phase approximation (RPA), as well as supercell calculations using the core-hole approximation within density functional theory (DFT). The binding energies of strongly bound excitations are determined in the materials, and core-exciton wavefunctions are demonstrated for LiF.
2009-03-11
The Possibility of Digital Imaging in the Diagnosis of Occlusal Caries
UK PubMed Central (United Kingdom)
The aim of this study was to assess the possibility of digital image analysis of pit-and-fissure discoloration in order to diagnose caries. Digital images showing pit-and-fissure discoloration in 100...Full Text Available
2010-01-01
Self-Study Digital Library Courseware
Tutorial on digital libraries. Site also contains links to other reference materials on digital libraries as well as links to courses on the subject. Keywords: Information Systems - Information Systems Applications, Information Storage and Retrieval, Database Management, multimedia
2001-12-01
UK PubMed Central (United Kingdom)
Objective: The paper describes and evaluates the use of Clinical Digital Libraries Project (CDLP) digital library collections in terms of their facilitation of timely clinical information...Full Text Available
2006-04-01
A System for the Recording of Clinical Data as an Aid in the Diagnosis of Bovine Digital Disease
UK PubMed Central (United Kingdom)
A form for the clinical evaluation of bovine digital disease was developed. In this article, each section of the resulting Digit Evaluation Form is discussed and justified. By following the...Full Text Available
1986-08-01
Digital AVR application to power plants
Energy Technology Data Exchange (ETDEWEB)
The digital AVR must have the level of redundancy and control functions that conform to the configuration of the excitation control system and to the importance of a particular generator for the user. The digital AVR is not simply a digital version of the analog AVR, but can realize sophisticated control functions that were difficult to achieve with analog circuits, thus making it possible to enhance the stability of power system by PSS (power system stabilizer). This paper describes the test results of the digital AVRs applied to power plants, their system configuration and functions, as well as the outline of an auto-tuning PSS or AT-PSS planned to be incorporated in the digital AVR in the future.
1993-12-01
''SEPIO NUANCE DT'' digital mammography system
International Nuclear Information System (INIS)
In the past, the need for high quality images, i.e., very sharp and clear images, in mammography have prevented mammography equipment from being digitalized; however, recent advances in detection technology such as development of a high resolution digital X-ray detector have produced improvements in digital mammography. Digital mammography is expected to replace conventional film-screen mammography. We have developed a digital mammography system, named ''SEPIO NUANCE DT'', which is equipped with a direct conversion flat panel detector. The present paper describes the high basic performance and user-friendly functions of the system. (author)
2007-03-01
Real-time digital libraries based on widely distributed, high performance management of large-data-objects
1997-01-01
Internet and Electronic Information Management
... 6(2): 36-45. Hedstrom, M. (1998). Digital preservation: a time bomb for digital libraries. [Online]. Available: http://www.uky ...
2004-12-01
Digitizing Dissertations for an Institutional Repository: A Process and Cost Analysis*
UK PubMed Central (United Kingdom)
Objective:This paper describes the Lamar Soutter Library's process and costs associated with digitizing 300 doctoral dissertations for a newly implemented institutional repository...Full Text Available
2008-07-01
Digital Hearing Aids: Current "State-of-the-Art"
... promise of highly advanced signal processing, ensured that digital hearing aid technology had come of age. So how far have ...
Single exposure energy subtraction chest radiography in the diagnosis of pulmonary cancer
Energy Technology Data Exchange (ETDEWEB)
A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is considered to be one of the routine examinations, in view of low exposure doses. The ...
1987-03-01
Single exposure energy subtraction chest radiography in the diagnosis of pulmonary cancer
International Nuclear Information System (INIS)
A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is considered to be one of the routine examinations, in view of low exposure doses. The ...
1987-01-01
UK PubMed Central (United Kingdom)
BackgroundThe construction of cDNA libraries is a useful tool to understand gene expression in organisms under different conditions, but random sequencing of unbiased cDNA collections...Full Text Available
International Nuclear Information System (INIS)
Sonography, subtraction scintigraphy, computed tomography and MRI were compared in 100 patients who had surgery 105 times for hyperparathyroidism (HPT). Surgical and pathological data were available for all operations. A total of 105 MR, 77 CT, 84 sonograms and 70 subtraction scintigrams were performed. The ability of the imaging modalities, individually and in combination, to detect HPT, histology, size, concomitant thyroid disease and location of the diseased glands has been evaluated. For primary HPT, sensitivity ranged from 68% for MRI to 40% for scintigraphy but was much lower for tertiary HPT with all modalities. The ability to identify diseased glands was strongly size dependent for all methods. If patients had had previous neck surgery, the most sensitive methods were MRI and scintigraphy and this also held true for patients with concomitant thyroid disease and ectopically located glands. The findings presented suggest that while ...
UK PubMed Central (United Kingdom)
Picocyanobacteria of the genus Synechococcus are important contributors to marine primary production and are ubiquitous in the world's oceans. This genus is genetically diverse, and...Full Text Available
2006-04-01
Local Structures and Interface Morphology of InGaAsN Thin Films Grown on GaAs
Energy Technology Data Exchange (ETDEWEB)
The compound semiconductor system InGaAsN exhibits many intriguing properties which are particularly useful for the development of innovative high efficiency thin film solar cells and long wavelength lasers. The bandgap in these semiconductors can be varied by controlling the content of N and In and the thin films can yet be lattice-matched to GaAs. In the present work, x-ray absorption fine structure (XAFS) and grazing incidence x-ray scattering (GIXS) techniques have been employed to probe the local environment surrounding both N and In atoms as well as the interface morphology of InGaAsN thin films epitaxially grown on GaAs. The soft x-ray XAFS results around nitrogen K-edge reveal that N is in the sp{sup 3} hybridized bonding configuration in InGaAsN and GaAsN, suggesting that N impurities most likely substitute for As sites in these two compounds. The results of In K-edge XAFS suggest a possible trend of a slightly larger coordination ...
1999-02-23
Energy Technology Data Exchange (ETDEWEB)
X-ray magnetic circular dichroism (XMCD) was used to probe the existence of induced magnetic moments in yttrium iron garnet (YIG) films in which yttrium is partly substituted with lanthanum, lutetium or bismuth. Spin polarization of the 4d states of yttrium and of the 5d states of lanthanum or lutetium was clearly demonstrated. Angular momentum resolved d-DOS of yttrium and lanthanun was shown to be split by the crystal field, the two resolved substructures having opposite magnetic polarization. The existence of a weak orbital moment involving the 6p states of bismuth was definitely established with the detection of a small XMCD signal at the Bi M{sub 1}-edge. Difference spectra also enhanced the visibility of subtle changes in the Fe K-edge XMCD spectra of YIG and {l_brace}Y, Bi{r_brace}IG films. Weak natural X-ray linear dichroism signatures were systematically observed with all iron garnet films and with a bulk YIG single crystal cut parallel to the (1 1 1) ...
2009-12-15
Cerebral angiography using Fuji computed radiography (FCR) system
International Nuclear Information System (INIS)
Eighty-seven subtraction images of FCR were compared with subtraction images of conventional angiography. Although FCR images with reduced exposure dose (25 % of regular dose) and with diluted contrast material (150 mgI/ml, 50 % of usual concentration) were slightly inferior to the images of conventional angiography, most clinically important vessels were adequately visualized. As FCR has wider dynamic range and higher contrast resolution than conventional angiography, FCR may take over conventional angiography. (author).
1985-01-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: The aim of this study was to test the feasibility of iliac artery stent placement under MR guidance with real-time MR radial scanning in an animal model. Materials and methods: The experiments were performed on three pigs in a 1.5 T scanner. Radial scanning with a gradient echo technique (T{sub R} 8.4 ms, T{sub E} 3.6 ms, flip angle 10 ) was used. A dedicated backprojector performed the reconstruction of the raw data in real-time. The resulting MR-images were displayed on LCD screens beside the magnet. The sliding window reconstruction technique allowed image acquistion at a frame rate of 16 images per second. MR-compatible self-expanding stents with a diameter of 8 mm and a length of 3 cm were placed into the left iliac artery. Their positions were verified by digital subtraction angiography (DSA) and compared to MRI. Results: All stents were successfully placed. Stent positions as monitored by real-time MR were identical to those ...
1998-12-01
Flow Vaporization of CO{sub 2} in Microchannel Tubes
Energy Technology Data Exchange (ETDEWEB)
Carbon dioxide is receiving renewed interest as an efficient and environmentally safe refrigerant in a number of applications, including mobile air conditioning and heat pump systems, and hot water heat pumps. Compact heat exchangers for CO{sub 2} systems are designed with small-diameter tubing. The purpose of this study is therefore to provide a better basis for understanding and predicting heat transfer and pressure drop during flow vaporization of CO{sub 2} in microchannels. The ''unusual'' properties of carbon dioxide give heat transfer and two-phase flow characteristics that are very different from those of conventional refrigerants. Examples of these differences are the much higher pressure, the resulting high vapour density, a very low surface tension, and a low liquid viscosity. High pressure and low surface tension has a major effect on nucleate boiling characteristics, and earlier test data have shown a clear dominance of nucleate boiling ...
2002-07-01
Usability Studies and User-Centered Design in Digital Libraries
Digital libraries continue to flourish. At the same time, the principles of user-centered design and the practice of usability testing have been growing in popularity, spreading their influence into the library sphere. This article explores the confluence of these two trends by surveying the current literature on usability studies of digital libraries. This article focuses on the methodology of studies of multimedia digital libraries. (Contains 1 table and 45 notes.)
2007-12-01
British Library Electronic Table of Contents (United Kingdom)
SummaryThis paper evaluates the status of digitization in 30 Nigerian university libraries with a view to identifying the status, progress, prospects and challenges to digitize library materials and form the basis of providing a roadmap to successful execution of digitization projects. The study assessed the status of digitization of past question papers, theses and dissertations in Nigerian university libraries from May to September 2006 through a self-administered questionnaire, site visits and interviews. It was found that, though there are automation services in those universities, there is no digitization of these materials mentioned in the surveyed institutions. The major obstacles militating against digitizing in the university libraries include lack of funds, lack of appropriate fa...
2007-01-01
Giving voice to the past: digitizing oral history
British Library Electronic Table of Contents (United Kingdom)
Purpose - The purpose of this paper is to describe the processes and procedures utilized by Jacksonville State University's Houston Cole Library to digitize an oral history collection and provide access to it through the Library's catalog, web presence, and the state-wide digital repository initiative, Alabama Mosaic (see www.alabamamosaic.org). Design/methodology/approach - The paper is based on the Library's experiences in acquiring, digitizing, creating metadata for and making accessible a collection of oral histories. Findings - The paper describes the obstacles overcome, issues encountered, procedures established, and ramifications of the project. Practical implications - Many institutions are currently digitizing unique collections as part of repository initiatives, both institutiona...
2009-01-01
Compressed-shell integrity measurements in spherical implosion experiments
International Nuclear Information System (INIS)
The shell integrity near peak compression of spherical implosions using the 60-beam, 30-kJ UV OMEGA laser system [Opt. Commun. 133, 495 (1997)] has been measured. Hot core emission backlights a shell with a thin titanium-doped layer that is imaged at x-ray photon energies above and below the titanium K edge. The x-ray intensity ratio between the two images is related to perturbations in the cold, or absorbing, part of the shell. The measured cold-shell areal-density modulations, integrated over the time of peak compression, are of the order of 25% to 50% with nonuniformity spectra peaked at spatial wavelengths of 30 to 50 #mu#m and with the smallest detectable nonuniformity features extending down to spatial wavelengths of 12 to 15 #mu#m. Hot-shell areal-density modulations of the emitting part of the shell (inner edge) are of the order of 13% to 20%. The measured shell modulations are in agreement with the results of two-dimensional ...
2001-06-01
Anisotropy in Magnetic Properties and Electronic Structure of Single Crystal LiFePO4
Energy Technology Data Exchange (ETDEWEB)
We report the experimental and theoretical results on the anisotropies in the magnetic properties and x-ray absorption spectra of single-crystal LiFePO4. A mean-field theory is developed to explain the observed strong anisotropies in Lande g-factor, paramagnetic Curie temperature, and effective moment for LiFePO4 single crystals. The values of the in-plane nearest- and next-nearest-neighbor spin exchange (J1 and J2), interplane spin exchange (J{perpendicular}), and single-ion anisotropy (D), obtained recently from neutron scattering measurements, are used for calculating the Curie temperatures with the formulas derived from the mean-field Hamiltonian. It is found that the calculated Curie temperatures match well with that obtained by fitting the magnetic susceptibility curves to the modified Curie-Weiss law. For the polarized Fe K-edge x-ray absorption spectra of single-crystal LiFePO4, a different feature assignment for the 1s4p transition features is proposed and ...
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
WELLOG is a system of programs developed at the Earth Science Laboratory to be used to digitize well logs and perform some analysis and plotting of the data. Multiple logs can be plotted side by side for correlation analysis and up to three logs can be plotted in a cross plot. Data entry and editing functions are also provided by the programs. This system of well log interpretation programs is presently operating on the University of Utah UNIVAC 1108 computer. Digitizing of well logs is accomplished by an old model CALMA (off-line) digitizer. Those parts of WELLOG that handle the digitized data tapes are extremely machine dependent. The parts of WELLOG that produce the plots and handle the data beyond the digitized data tape are more portable.
1980-03-01
[75Se]Selenomethionine scanning for parathyroid localization should be abandoned
International Nuclear Information System (INIS)
Image subtraction techniques, in conjunction with [75Se]selenomethionine (75Se) scintigraphy, have recently been suggested to be a potentially valuable tool for localization of parathyroid abnormalities. With use of these techniques, we prospectively studied 15 patients scheduled for parathyroid operations. Postoperatively, all were normocalcemic. Anterior scintiscans of the neck were divided into quadrants, and regions of enhanced uptake were assigned to one or more quadrants. On this basis, by chance alone a minimum of 25% of single-gland enlargements would be assigned to the correct quadrant of the neck. We found that by use of 75Se scanning only 8 of 22 abnormal glands (36%) were assigned to the quadrant of the neck in which they were found intraoperatively. In no case was a clearly visualized focus of parathyroid activity encountered. These results do not justify the continued use of 75Se scintigraphy with or without image subtraction in ...
Groundtruth approach to accurate quantitation of fluorescence microarrays
Energy Technology Data Exchange (ETDEWEB)
To more accurately measure fluorescent signals from microarrays, we calibrated our acquisition and analysis systems by using groundtruth samples comprised of known quantities of red and green gene-specific DNA probes hybridized to cDNA targets. We imaged the slides with a full-field, white light CCD imager and analyzed them with our custom analysis software. Here we compare, for multiple genes, results obtained with and without preprocessing (alignment, color crosstalk compensation, dark field subtraction, and integration time). We also evaluate the accuracy of various image processing and analysis techniques (background subtraction, segmentation, quantitation and normalization). This methodology calibrates and validates our system for accurate quantitative measurement of microarrays. Specifically, we show that preprocessing the images produces results significantly closer to the known ground-truth for these samples.
2000-12-01
Clinical evaluations of intra-arterial subtraction angiography using Fuji computed radiography
International Nuclear Information System (INIS)
Intra-arterial subtraction angiography(IADSA) using Fuji computed radiography(FCR) was performed on 130 patients with cervical, pelvic, peripheral and abdominal diseases. It was compared with conventional angiography(radiographs produced by combining photographic film with an intensifying screen) performed on same patients. Radiographs produced by FCR were better than conventional radiographs in cervical, pelvic and peripheral angiography. In the abdominal angiography using FCR, there was misregistration artifact in some cases, but in hepatic angiography, the new radiographs under the injection of small amount of contrast medium(about 10ml) and the short exposure duration(about 10 seconds) were excellent. It was as valuable as conventional angiography (infusion hepatic angiography) for diagnosing hepatic neoplasms. (author).
1985-01-01
Angiography of the head using Fuji computed radiography (FCR) system
International Nuclear Information System (INIS)
Forty-seven subtraction images of FCR were compared with subtraction images of conventional angiography of the head. Quality of the FCR images were equal or superior to that of conventional angiography. Antero-posterior projection of external carotid arteriography by FCR was most useful because of its wide dynamic range. As contrast resolution of FCR is superior to that of conventional angiography, only half diluted contrast media was needed. As for spacial resolution, FCR is slightly inferior to conventional angiography. However, most vessels which are clinically important were adequately demonstrated. A weak point of FCR which should be improved is relatively long time to process the images after radiation exposure. (author).
1985-01-01
Programma PLOT per l'esecuzione ed il confronto di grafici con l'RGL-library del VAX-11/780 Digital
Programma PLOT per l'esecuzione ed il confronto di grafici con l'RGL-library del VAX-11/780 Digital
1985-01-01
UK PubMed Central (United Kingdom)
BackgroundThe purpose of our investigation was to compare a digital templating system to conventional templating techniques when preoperatively planning for total hip arthroplasty.MethodsWe...Full Text Available
2009-02-01
Diagnostic quality of low resolution images for tele-woundcare.
UK PubMed Central (United Kingdom)
The use of digital wound images would allow remote consultation between patients, physicians, or other caregivers over the Internet. To evaluate the efficacy and validity of digital images for assessment...Full Text Available
1998-01-01
Cost analysis of a project to digitize classic articles in neurosurgery*
UK PubMed Central (United Kingdom)
In summer 2000, the Cushing/Whitney Medical Library at Yale University began a demonstration project to digitize classic articles in neurosurgery from the late 1800s and early 1900s. The objective of...Full Text Available
2002-04-01
International Nuclear Information System (INIS)
Objective: To evaluate the quality and usefulness of direct digital radiography system in roentgenogram of chest in clinical practice. Methods: 1000 cases of chest roentgenograms with digital radiography and high kV conventional radiography were selected for analysis by 3 senior radiologists. Results: 1. With digital radiography system, the quality of chest film was assessed as grade A in 50.6%, grade B in 38.5%, grade C in 10.9%, and no waste film. 2. With conventional high kV radiography, the quality of chest film was assessed as grade A in 41.1%, grade B in 44.1%, grade C in 13.3%, and waste film in 1.5%. The direct digital radiography was statistically superior to the conventional high kV radiography. 3. The fine structure of the lungs could be revealed in 100.0% of chest roentgenogram with direct digital radiograph system, which was significantly higher than that acquired with ...
2003-02-01
Association of Unique, Isolated Treponemes with Bovine Digital Dermatitis Lesions?
UK PubMed Central (United Kingdom)
This study used a PCR-based approach targeting 16S rRNA gene fragments to determine the occurrence and association of the three bovine digital dermatitis (BDD) treponeme phylogroups within lesions found...Full Text Available
2009-03-01
UK PubMed Central (United Kingdom)
Several efforts have been made to completely automate cephalometric analysis by automatic landmark search. However, accuracy obtained was worse than manual identification in every study. The analogue-to-digital...Full Text Available
2009-01-01
A Revised/Proposed Nomenclature for the External Anatomical Features of the Bovine Foot
UK PubMed Central (United Kingdom)
Several widely recognized sources of nomenclature regarding the bovine external digit were reviewed, compared, and utilized in a clinical survey of bovine digital disease. During this process, some...Full Text Available
1988-05-01
UK PubMed Central (United Kingdom)
BackgroundThis in vitro study was conducted to compare the accuracy of two digital image receptors in identifying the location of tip of a fine endodontic file and radiographic apex...Full Text Available
2010-11-01
Untitled - NASA Technical Report Server (NTRS)
Directional audio technology for headphone applications is being developed. A laboratory demonstration model of a real-time digital ...
sharing data and computational resources, and accessing information in digital libraries." Bill Wulf (1989) In a Collaboratory, the presentation/meeting concept embodied...
2011-10-07
Technology in Coalition Training
... program incorporates the proven concepts of advanced distributed learning, modeling and simulation, and electronic digital libraries (Figure 1) to ...
2004-06-01
... 15, 14, Robert Constable, Cornell University, NY, Building Interactive Digital Libraries of Formal Algorithmic Knowledge, Navy. ...
Magnetic Tape Pulse Width to Digital Convertor.
... This is achieved by the use of a unique logic circuit employing a plurality of flip-flop devices, multivibrators and AND gates. ...
1976-12-07
DVRPC 2010 Digital Orthoimagery - Mr.SID County Mosaics
... image overlap between adjacent tiles. Orthoimagery processed by BAE Systems....
Considerations in the Design and Development of a Human ...
... appropriate. At press time, the laws governing the use of digital audio technology and the technology itself are rapidly changing. ...
1990-09-20
The Digital Raster Graphic (DRG) is a raster image of a scanned USGS topographic map including the collar information, georeferenced to the UTM grid....
International Nuclear Information System (INIS)
Radiology departments often underestimate the importance of protecting medical data during transmission, including the precautions taken to ensure data protection. In teleradiology, transmitted as well as stored patient data have to be signed digitally according to the currently valid regulation (Roentgenverordnung, RoeV). The DICOM standard facilitates a digital signature. So far, medical image manufacturers only announced to support this security feature. We introduce a solution that extends the feature of digital signing to older modalities. (orig.)
2005-01-01
A DIGITAL READOUT TECHNIC APPLICABLE TO ...
... small. and hundreds decades. The outputs of both multivibrators are con- nected to an "and" circuit, which will put out 5 ...
1963-02-01
02.10.10 - NASA and Texas Instruments are using the theme of human space exploration to develop digital libraries of math and science problems for high ...
Recommending Related Papers Based on Digital Library Access Records
An important goal for digital libraries is to enable researchers to more easily explore related work. While citation data is often used as an indicator of relatedness, in this paper we demonstrate that digital access records (e.g. http-server logs) can be used as indicators as well. In particular, we show that measures based on co-access provide better coverage than co-citation, that they are available much sooner, and that they are more accurate for recent papers.
2007-01-01
Digital Libraries from Concept to Practice
The paper represents the result of research in the field of digital libraries functionalities in the context of new Grid infrastructure support. It is defined a new vector of knowledge society, informational vector - content vector. It presents a Grid European project which includes Romanian partners, and it defines on this base a digital library model which can be applied for the libraries in Romania.
2007-01-01
International Nuclear Information System (INIS)
Digital radiography for diagnosis of chest diseases using Fuji Computed Radiography (FCR) was evaluated. The results were as follows; 1. Compared to the conventional chest X-ray films, various types of image enhancement could be made by manipulation of the digital information such as tone conversion, spatial frequency modification etc. 2. Digital radiography lessens the X-ray exposure dose and will ultimately permit speedy transmission of image data from outlying clinics to central processing hospitals. 3. Digital radiographic images are useful in chest X-ray diagnosis especially in mass surveys for lung cancer and in primary care medicine because of its full imaging capability. (author).
1983-01-01
Digital mammography: more microcalcifications, more columnar cell lesions without atypia
British Library Electronic Table of Contents (United Kingdom)
The incidence of columnar cell lesions in breast core needle biopsies since full-field digital mammography in comparison with screen-filmed mammography was analyzed. As tiny microcalcifications characterize columnar cell lesions at mammography, we hypothesized that more columnar cell lesions are diagnosed since full-field digital mammography due to its higher sensitivity for microcalcifications. In all, 3437 breast core needle biopsies performed in three hospitals and resulting from in total 55?159 mammographies were revised: 1424 taken in the screen-filmed mammography and 2013 in the full-field digital mammography period. Between the screen-filmed mammography and full-field digital mammography periods, we compared the proportion of mammographies that led to core needle biopsies, the...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
In embodiments, spectroscopic monitor monitors modulated light signals to detect low levels of contaminants and other compounds in the presence of background interference. The monitor uses a spectrometer that includes a transmissive modulator capable of causing different frequency ranges to move onto and off of the detector. The different ranges can include those with the desired signal and those selected to subtract background contributions from those with the desired signal. Embodiments of the system are particularly useful for monitoring metal concentrations in combustion effluent.
2003-01-01
International Nuclear Information System (INIS)
Eight patients with primary hyperparathyroidism were examined preoperative to locate the affected parathyroid glands. The localisation was done with technetium 99m and thallium 201. This new method seems to be of great value to locate preoperative the affected parathyroid glands. (R.B.).
Energy Technology Data Exchange (ETDEWEB)
Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: (1) conventional radiography (CXR), (2) low kV conventional radiography (Low), (3) Fuji computed radiography (FCR), (4) bone images with conventional singles exposure energy subtraction (ES) and (5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, images of 42 lung nodules (21 calcified lung nodules and 21 ...
1995-08-01
International Nuclear Information System (INIS)
Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: 1) conventional radiography (CXR), 2) low kV conventional radiography (Low), 3) Fuji computed radiography (FCR), 4) bone images with conventional singles exposure energy subtraction (ES) and 5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, images of 42 lung nodules (21 calcified lung nodules and 21 ...
1995-01-01
The KSNPP risk-effect analysis of the digital safety-critical systems
Energy Technology Data Exchange (ETDEWEB)
The study was performed for evaluating the risk effect of digital systems on the total plant. Based on risk monitor, a fault tree model for the Korean Standard Nuclear Power Plants (KSNPP), we integrate the fault-tree models for Digital Plant Protection System (DPPS) and Digital Engineered SaFety Actuation System (DESFAS) which are the most important safety-critical I and C systems in the KSNPP. In this study, however, three important factors (the probabilities of manual actuation failure, the software failure probability, and the watchdog timer fault coverage) are treated as the variables of the sensitivity study because quantification methodologies for these factors are not developed yet. Not only the unavailability of digital safety-critical system itself, but also the risk effect of digital systems on the total plant should be assessed to prove the safety of ...
2004-02-01
Reliability assessment of embedded digital system using multi-state function
Energy Technology Data Exchange (ETDEWEB)
This work describes a combinatorial model for estimating the reliability of the embedded digital system by means of multi-state function. This model includes a coverage model for fault-handling techniques implemented in digital systems. The fault-handling techniques make it difficult for many types of components in digital system to be treated as binary state, good or bad. The multi-state function provides a complete analysis of multi-state systems as which the digital systems can be regarded. Through adaptation of software operational profile flow to multi-state function, the HW/SW interaction is also considered for estimation of the reliability of digital system. Using this model, we evaluate the reliability of one board controller in a digital system, Interposing Logic System (ILS), which is installed in YGN nuclear power units 3 and 4. Since the proposed ...
2006-03-15
Energy Technology Data Exchange (ETDEWEB)
The Linac Coherent Light Source (LCLS) is required to deliver a high quality electron beam for producing coherent X-rays. As a result, high resolution beam position monitoring is required. The Beam Position Monitor (BPM) digitizer acquires analog signals from the beam line and digitizes them to obtain beam position data. Although Matlab is currently being used to test the BPM digitizer?s functions and capability, the Controls Department at SLAC prefers to use Experimental Physics and Industrial Control Systems (EPICS). This paper discusses the transition of providing similar as well as enhanced functionalities, than those offered by Matlab, to test the digitizer. Altogether, the improved test stand development system can perform mathematical and statistical calculations with the waveform signals acquired from the digitizer and compute the fast Fourier transform (FFT) of the signals. ...
2011-06-22
Simulation of non-linear and switching elements for transient analysis based on wave digital filters
A previous paper introduced the use of wave digital filters as a basic building block for power system simulation, particularly suitable for real-time applications. This paper stresses the simulation of non-linear and switching elements, emphasizing the advantages of the wave filters implementation. The digital structure is maintained even when non-linear components change their characteristics or power electronic devices switch their states. As a very important by-product, the suppression of numerical oscillations related to the trapezoidal rule is achieved in a rather simple way, with no effects on simulation results.
1996-10-01
A navigation filter for fusing DTM/correspondence updates
An algorithm for pose and motion estimation using corresponding features in images and a digital terrain map is proposed. Using a Digital Terrain (or Digital Elevation) Map (DTM/DEM) as a global reference enables recovering the absolute position and orientation of the camera. In order to do this, the DTM is used to formulate a constraint between corresponding features in two consecutive frames. The utilization of data is shown to improve the robustness and accuracy of the inertial navigation algorithm. Extended Kalman filter was used to combine results of inertial navigation algorithm and proposed vision-based navigation algorithm. The feasibility of this algorithms is established through numerical simulations.
2011-01-01
U.S. Department of the Interior Library - Reference Sources on...
and Vendors on the Web Bartleby.com "Great books online." Electronic Texts & Digital Libraries Links to the full text of books and other texts on the Web. Law and Politics...
2011-05-06
Providing online access to historic films at the Washington State University libraries
British Library Electronic Table of Contents (United Kingdom)
Purpose - This paper aims to discuss the procedures and methods developed at Washington State University to digitize and make accessible historic moving images. Design/methodology/approach - The paper describes the selection and the use of low-cost technologies to transfer analog film to digital formats. Issues related to the conversion, description, and online hosting of digital films are also addressed. Findings - Though the steps involved in digitizing film are not trivial, the benefits of access both for the public and archives staff outweigh the expense and labor involved. The procedures described in this paper involve low upfront costs and are sustained through cost recovery fees. Research limitations/implications - The focus of this paper is on managing, describing, and providing on...
2011-01-01
Photo Tours: Gulf of Mexico Integrated Science
Inventory Project home page Reports, Posters, Presentations Internet Tools - Digital Libraries, IMS's Maps, Aerial Photographs Meetings & Conferences Photo Tours - all...
2011-10-08
NASA partners with teacher institute NASA strives to improve computers
of the digital hearing aid technology that led to the cochlear implant. Former. Marshall Space Flight Center engineers. John Richardson and Joseph Howard ...
NASA Project Inducted Into Space Technology Hall of
Apr 9, 2003 ... Adam Kissiah Jr., a retired KSC engineer, will be honored for his development of the digital hearing aid technology that led to the cochlear ...
Laser-assisted solar cell metallization processing - NASA ...
Oct 15, 1985 ... Title: Laser-assisted solar cell metallization processing. No Digital Version Available: Go to Tips on Ordering ...
LCP-10 Intelligibility of Oxygen Masks and Microphones in ...
... JTIDS) LPC-10 voice channel has been an important facet of a larger ongoing in-house research task on Digital Audio Technology for Aircraft ...
1988-10-24
Directory of Scientists: Gulf of Mexico Estuaries Integrated...
Inventory Project home page Reports, Posters, Presentations Internet Tools - Digital Libraries, IMS's Maps, Aerial Photographs Meetings & Conferences Photo Tours - all...
2011-10-08
Conference on Information Technology (2nd)/Special Session ...
... Topics includes: Formal methods in information engineering, Electronic documents and digital libraries Autonomous robots in embeded systems ...
2004-08-23
Concurrent Error-Detecting Codes for Arithmetic Processors
2 is self-checking as described by Kolupaev. (ref. 21). ..... Kolupaev, S. G.: Self-Testing Residue. Trees. TR-49, Digital Systems ...
Center for Intelligent Information Retrieval
evaluation, novelty detection, resource discovery, interfaces and visualization, digital libraries, computational social science, and cross-lingual information retrieval. The CIIR...
2011-08-31
Army Communicator. Volume 32, Number 2, Spring 2007
... Introduction to the Signal Regiment Cisco Academy 1-4 (CCNA) Engineering Math Basic Electronics/Digital Logic (replaced C Programming ...
2011-05-14
A method of stereotaxic localization adopted for conventional and digital radiography
International Nuclear Information System (INIS)
A method for the determination of stereotaxic coordinates in radiography, e.g. angiography, pneumoencephalography or digital vascular radiography, is described. A special localization frame containing radiopaque structures and scales defines a diagnostic coordinate system. This frame is fixed to the X-ray-table prior to the radiographic procedure and two projections are obtained at arbitrary angles to each other. The focus-film distances do not have to be fixed. The target coordinates are then determined either by a simple graphical procedure or with the use of a digitizing x-y-table, by a computer. With the computer method the films are placed on the digitizing table and the target and a few reference points are marked using a cursor. From the relative positions the computer calculates the coordinates. With the special head fixation system, coordinates of structures visualized in radiographic examinations can be ...
1986-01-01
International Nuclear Information System (INIS)
Twenty-two patients, all with surgically proven primary hyperparathyroidism, were studied by TI-201 thallous chloride and Tc-99m pertechnetate subtraction imaging. Fifteen parathyroid adenomata and one hyperplastic gland between 0.33 and 14.8 g were correctly localized in 16 patients. Two adenomata and seven hyperplastic or histologically normal parathyroids between 0.1 g and 1.4 g in seven patients were not localized. One patient had a correctly localized 13.0-g adenoma with a nonlocalized 0.3 g hyperplastic parathyroid gland and there were two false positive localizations. Sensitivity was 64% (glands), and 73% (patients). There was only fair correlation with parathormone (PTH) levels, but these were elevated in all but four of the patients with correctly localized parathyroids. The authors conclude that the imaging procedure is useful but its sensitivity is limited by difficulty in localizing correctly small glands, particularly those of less than 0.5 g, which ...
HST/ACS observations of shell galaxies: inner shells, shell colours and dust
AIM:Learn more about the origin of shells and dust in early type galaxies. METHOD: V-I colours of shells and underlying galaxies are derived, using HST Advanced Camera for Surveys (ACS) data. A galaxy model is made locally in wedges and subtracted to determine shell profiles and colours. We applied Voronoi binning to our data to get smoothed colour maps of the galaxies. Comparison with N-body simulations from the literature gives more insight to the origin of the shell features. Shell positions and dust characteristics are inferred from model galaxy subtracted images. RESULT: The ACS images reveal shells well within the effective radius in some galaxies (at 1.7 kpc in the case of NGC 5982). In some cases, strong nuclear dust patches prevent detection of inner shells. Most shells have colours which are similar to the underlying galaxy. Some inner shells are redder than the galaxy. All six shell galaxies show out of dynamical equilibrium dust ...
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
Manganese model complexes, relevant to the oxygen-evolving complex (OEC) in photosynthesis, were studied with Mn K-edge X-ray absorption near-edge spectroscopy (XANES), Mn Kb X-ray emission spectroscopy (XES), and vibrational spectroscopy. A more detailed understanding was obtained of the influence of nuclearity, overall structure, oxidation state, and ligand environment of the Mn atoms on the spectra from these methods. This refined understanding is necessary for improving the interpretation of spectra of the OEC. Mn XANES and Kb XES were used to study a di-(mu)-oxo and a mono-(mu)-oxo di-nuclear Mn compound in the (III,III), (III,IV), and (IV,IV) oxidation states. XANES spectra show energy shifts of 0.8 - 2.2 eV for 1-electron oxidation-state changes and 0.4 - 1.8 eV for ligand-environment changes. The shifts observed for Mn XES spectra were approximately 0.21 eV for oxidation state-changes and only approximately 0.04 eV for ligand-environment changes. This ...
2001-05-16
X-ray absorption spectroscopy of bacterial sulfur globules
Energy Technology Data Exchange (ETDEWEB)
Sulfur K-edge X-ray absorption spectroscopy is a powerful in situ probe of sulfur biochemistry in intact cells and tissues. Under favorable circumstances the technique can provide quantitative information on the chemical identify of the sulfur species that are present in a sample. Prange et al. have recently reported an X-ray absorption spectroscopic study of bacterial sulfur storage globules. Unfortunately there are substantial problems with the experimental technique employed that, they contend, lead to completely erroneous conclusions. In the more recent of their two papers Prange et al. employed a curve-fitting method similar to that used by us (for more than 10 years). In essence, the method employs simply fitting a linear combination of the spectra of standard compounds to that of the unknown, in this case cultures of bacterial cells. This type of analysis can provide quantitative estimates of the individual sulfur types in the sample, but is critically ...
2002-08-01
International Nuclear Information System (INIS)
A new iron phosphate (NH4)4Fe3(OH)2F2[H3(PO4)4] has been synthesized hydrothermally at HF concentrations from 0.5 to 1.2 mL. Single-crystal X-ray diffraction analysis reveals its three-dimensional open-framework structure (monoclinic, space group P21/n (No. 14), a=6.2614(13) A, b=9.844(2) A, c=14.271(3) A, ?=92.11(1)o, V=879.0(3) A3). This structure is built from isolated linear trimers of corner-sharing Fe(III) octahedra, which are linked by (PO4) groups to form ten-membered-ring channels along [1 0 0]. This isolated, linear trimer of corner-sharing Fe(III) octahedra, [(FeO4)3(OH)2F2], is new and adds to the diverse linkages of Fe polyhedra as secondary building units in iron phosphates. The trivalent iron at octahedral sites for the title compound has been confirmed by synchrotron Fe K-edge XANES spectra and magnetic measurements. Magnetic measurements also show that this compound exhibit a strong antiferromagnetic exchange below TN=17 K, consistent with ...
2010-12-01
New materials synthesis: characterization of some metal-doped antimony oxides
Energy Technology Data Exchange (ETDEWEB)
In order to understand the chemistry of altermetal dopants in antimony oxide, the detailed structural characterization of two ..beta..-Sb/sub 2/O/sub 4/ compounds is reported, Mo-doped ..beta..-Sb/sub 2/O/sub 4/ (1.5 metal%) and V-doped ..beta..-Sb/sub 2/O/sub 4/ (5 metal%). The methods used to characterize these materials are X-ray and neutron diffraction, scanning electron microscopy, Mo K-edge extended X-ray absorption fine structure spectroscopy, and elemental analysis. The atomic position of each of these dopants in Sb/sub 2/O/sub 4/ is radically different as is the overall effect on the host structure. Molybdenum does not substitute for Sb atoms, rather the Mo atoms are found in channels of electron density formed by Sb/sup 3 +/ lone pairs. The two nearest Sb/sup 3 +/ are absent and the oxygen stoichiometry is preserved. The formula is Sb/sub 1.97/Mo/sub 0.015/O/sub 4/. Vanadium incorporates substitutionally for the Sb/sup 3 +/ atoms and there are random ...
1986-10-01
An EXAFS investigation of the structures of bromocopper(II) complexes in some solutions
International Nuclear Information System (INIS)
The structures of bromocopper(II) complexes in methanolic (M1, M2, M3, M4), ethanolic (E), and aqueous (H) solutions were determined by the analyses of the Cu K- and Br K-edge EXAFS spectra using a curve-fitting method. The molar concentrations of Cu and Br in these solutions prepared by CuBr_2 and LiBr are 0.996 and 1.992 (M1), 1.015 and 5.381 (M2), 0.493 and 4.525 (M3), 0.260 and 4.073 (M4), 1.031 and 4.313 (E), and 0.982 and 5.426 (H). In M1 solution the interatomic distances for the Cu-O_e_q, Br_e_q-Cu, and Br_e_q-O_e_q (_e_q = equatorial) were 2.00A, 2.35A, and 3.15A respectively, and the Br_e_q-Cu-O_e_q angle was estimated as about 92 deg. Therefore, trans-dibromo bis(methanol)copper(II) complex with a slightly distorted planar structure was proposed to be dominant complex species in M1 solution. The interatomic distances in M2, M3, M4 and E solutions were 2.37A and 3.45A (average) for the Br_e_q-Cu and Br_e_q-Br_e_q respectively. The Br_e_q-Cu-Br_e_q angle, ...
Three-dimensional data processing for time resolved gamma-ray spectrometry
International Nuclear Information System (INIS)
A new acquisition and evaluation procedure has been introduced for the measurement of time-dependent processes in gamma-ray spectrometry, in order to extract more information, including half-lives, from the data recorded during acquisition and to enable a more comprehensive analysis of the results. These advanced, off-line data evaluation techniques improve the selectivity and the background subtraction and make it possible to estimate the important analytical parameters (e.g., half-lives) more accurately than with the usual decay curve fitting method. (author)
Moessbauer diffraction measurements on polycrystalline bcc iron
Energy Technology Data Exchange (ETDEWEB)
In the early days of Moessbauer spectroscopy, it was demonstrated that coherent scattering of photons emitted by a Moessbauer source can be observed. In spite of the fact that scattering experiments could give information not accessible by the absorption method, they are not widely used. The reasons for this are, on the one hand, experimental difficulties, and on the other hand, the form of the samples, which should be large single crystals in most cases. In this work, we present a Moessbauer diffraction measurement on polycrystalline bcc iron where these problems have been overcome. We demonstrate that using the kinematical theory of gamma-ray diffraction, useful information on the relative orientation of the crystallographic axis to the hyperfine field directions can be subtracted. (orig.)
1994-11-01
Energy Technology Data Exchange (ETDEWEB)
We discuss the inclusive production of D{sup *{+-}} mesons in {gamma}p collisions at DESY HERA, based on a calculation at next-to-leading order in the general-mass variable-flavor-number scheme. In this approach, MS subtraction is applied in such a way that large logarithmic corrections are resummed in universal parton distribution and fragmentation functions and finite mass terms are taken into account. We present detailed numerical results for a comparison with data obtained at HERA and discuss various sources of theoretical uncertainties. (orig.)
2009-02-15
Convection heat loss from a cavity receiver
Energy Technology Data Exchange (ETDEWEB)
The receiver whose convective heat loss test results are presented was designed to absorb 5 MW of solar energy, using a molten salt working fluid. During the tests, this receiver was brought to a temperature of about 343 C by a small group of heliostats. Total receiver heat loss due to emitted radiation, conduction and convection was first determined, and the convection loss was established by calculating the radiation and conduction losses analytically and subtracting their sum from the total. Losses due to convection are found to be 1.43 percent of the total heat input.
1984-02-01
Atomic photoelectric effect near threshold edges
Energy Technology Data Exchange (ETDEWEB)
Total photon attenuation coefficients near absorption edges are determined in certain suitable elements and compounds. Photoelectric cross sections for elements are deduced from these by subtracting the coherent and incoherent scattering cross sections as well as other elemental cross sections in the cases of compounds. Certain deviations are observed on comparison with the available theoretical and experimental compilations. The I/sub L//sub ..cap alpha..//Il x-ray intensity ratio measured by photon excitation near threshold is found to agree better with the theory than the other available experimental data.
1985-07-01
Atomic photoelectric effect near threshold edges
International Nuclear Information System (INIS)
Total photon attenuation coefficients near absorption edges are determined in certain suitable elements and compounds. Photoelectric cross sections for elements are deduced from these by subtracting the coherent and incoherent scattering cross sections as well as other elemental cross sections in the cases of compounds. Certain deviations are observed on comparison with the available theoretical and experimental compilations. The I/sub L//sub #alpha#//Il x-ray intensity ratio measured by photon excitation near threshold is found to agree better with the theory than the other available experimental data.
1985-01-01
The power of digital audio in interactive instruction: An unexploited medium
Energy Technology Data Exchange (ETDEWEB)
Widespread use of audio in computer-based training (CBT) occurred with the advent of the interactive videodisc technology. This paper discusses the alternative of digital audio, which, unlike videodisc audio, enables one to rapidly revise the audio used in the CBT and which may be used in nonvideo CBT applications as well. We also discuss techniques used in audio script writing, editing, and production. Results from evaluations indicate a high degree of user satisfaction. 4 refs.
1989-01-01
Proceedings of the 1st ACM international conference on digital libraries
Energy Technology Data Exchange (ETDEWEB)
This document contains papers which were presented at the First ACM International Conference on Digital Libraries. Topics processed for this document included information retrieval and index structures for structured documents. Individual papers have been processed separately for the United States Department of Energy databases.
1996-12-31
Mammography: limits of a technique
International Nuclear Information System (INIS)
Breast cancer represents today more than 30% of all cancers and is responsible for about 20% of deaths due to cancer. The potentialities of mammography have increased in recent years through improvements in equipment and methodologies. In this paper the conventional mammography using film and image intensifiers is compared with digital mammography. Digital mammography presents clear advantages in storage and handling of information. Also its higher sensitivity will lead to an earlier detection of anomalies and a decrease in the number of invasive exams and surgeries
2001-05-01
Impact of computers in radiography: the advent of digital radiography, part-2
International Nuclear Information System (INIS)
Computed radiography (CR) systems use a photostimulable phosphor plate enclosed in a cassette. In CR, image acquisition is a two-stage process wherein image capture and image read out are done separately. Direct digital radiography (DR) systems, on the other hand, use detectors that have a combined image capture and image read out capability. DR systems are also called as DDR or ddR systems by some vendors. This article focuses on DR systems
2008-08-01
GaAs detector optimization for different medical imaging applications
International Nuclear Information System (INIS)
We have investigated the detection performance of GaAs detectors made with different thickness and contact geometries. A comparison is made between these detection capabilities and the imaging requirements for the following medical applications: digital mammography, digital chest radiography and nuclear medicine. Experimental results and preliminary images are presented and discussed. (author)
1999-09-11
From nuclear science symposium; San Francisco, California, USA (14 Nov 1973). A digital Fourier analyzer was programmed to perform reactor neutron noise analysis measurements and on-line processing of the data to obtain the steady-state reactivity. The system is suitable for recovering cross spectral density with low correlatedsignal component and for repetitive measurements with efficient use of reactor time. (auth)
1973-01-01
Digital signal processing for beam position feedback
Energy Technology Data Exchange (ETDEWEB)
Stabilization of the particle beam position with respect to the focusing optics in the third generation synchrotron light sources is crucial to achieving low emittance and high brightness. For this purpose, global and local beam orbit correction feedbacks will be implemented in the APS storage ring. In this article, the authors discuss application of digital signal processing to particle/photon beam position feedback using the PID (proportional, integral, and derivative) control algorithm.
1992-04-01
Digital optical processing system
Energy Technology Data Exchange (ETDEWEB)
Digital optical processing (DOP) was conceived to encompass the advantages of both electronic and optical processors, which are parallelism, flexibility, and high accuracy. The authors discuss the concept of parallelism, how it applies to DOP differently than to electronic parallel processing, and other potential advantages in using DOP. A PLZT memory device is described which can perform a series of logic or memory operations. From several of these PLZT devices a DOP is constructed to illustrate some of its programmability features.
1983-01-01
Automatically Generating Interfaces for Personalized Interaction with Digital Libraries
We present an approach to automatically generate interfaces supporting personalized interaction with digital libraries; these interfaces augment the user-DL dialog by empowering the user to (optionally) supply out-of-turn information during an interaction, flatten or restructure the dialog, and enquire about dialog options. Interfaces generated using this approach for CITIDEL are described.
2004-01-01
Autocontrol technique of combined centrifuges
International Nuclear Information System (INIS)
The design characteristic of the autocontrol technique of the combined centrifuge is introduced. Digital technique, vary structure control and interface technique, graphical display techniques, digital communication technique as well as electronic technique are applied in the course of research. Automation in the operation of large scale combined centrifuges and the course of combined test has been realized and it can coordinate with other systems of status monitoring, data collecting and centrifugal force-aerodynamic force matched load automatically
2009-12-01
Energy Technology Data Exchange (ETDEWEB)
A new era for the field of Galactic structure is about to be opened with the advent of wide-area digital sky surveys. In this article, the author reviews the status and prospects for research for 3 new ground-based surveys: the Sloan Digital Sky Survey (SDSS), the Deep Near-Infrared Survey of the Southern Sky (DENIS) and the Two Micron AU Sky Survey (2MASS). These surveys will permit detailed studies of Galactic structure and stellar populations in the Galaxy with unprecedented detail. Extracting the information, however, will be challenging.
1994-11-01
Mobile Computing in Digital Ecosystems: Design Issues and Challenges
In this paper we argue that the set of wireless, mobile devices (e.g., portable telephones, tablet PCs, GPS navigators, media players) commonly used by human users enables the construction of what we term a digital ecosystem, i.e., an ecosystem constructed out of so-called digital organisms (see below), that can foster the development of novel distributed services. In this context, a human user equipped with his/her own mobile devices, can be though of as a digital organism (DO), a subsystem characterized by a set of peculiar features and resources it can offer to the rest of the ecosystem for use from its peer DOs. The internal organization of the DO must address issues of management of its own resources, including power consumption. Inside the DO and among DOs, peer-to-peer interaction mechanisms can be conveniently deployed to favor resource sharing and data dissemination. Throughout this paper, we show that most of the ...
2011-01-01
International Nuclear Information System (INIS)
Present day mammography has not been able to make use of the advantages of digital luminescence radiography because of the limited spatial resolution. The recent development of electromagnetic focusing X-ray tube with effective focal spot sizes from 0.04 to 0.12 mm allows radiographic direct magnification with less geometric blur. It is now possible to combine direct magnification mammography with digital luminescence radiography. By combining high quality storage phosphor screens with an HQ-workstation a spatial resolution of 8 lp/mm is possible for 1.7-fold magnification. For 4-fold spot magnification views spatial resolution can be theoretically increased to approx. 20 lp/mm. One important advantage of digital radiography is the possibility of image-postprocessing. This article presents two sets of standard parameters and three sets of image dependent parameters for better imaging of specific lesions, such as ...
Co-Authorship Networks in the Digital Library Research Community
The field of digital libraries (DLs) coalesced in 1994: the first digital library conferences were held that year, awareness of the World Wide Web was accelerating, and the National Science Foundation awarded $24 Million (U.S.) for the Digital Library Initiative (DLI). In this paper we examine the state of the DL domain after a decade of activity by applying social network analysis to the co-authorship network of the past ACM, IEEE, and joint ACM/IEEE digital library conferences. We base our analysis on a common binary undirectional network model to represent the co-authorship network, and from it we extract several established network measures. We also introduce a weighted directional network model to represent the co-authorship network, for which we define $AuthorRank$ as an indicator of the impact of an individual author in the network. The results are validated against conference program committee ...
2005-01-01
Digital libraries play a crucial role in distance learning. Nowadays, they are one of the fundamental information sources for the students enrolled in this learning system. These libraries contain huge amount of instructional data (text, audio and video) offered by the distance learning program. Organization of the digital libraries is therefore very important for easy and fast access to the desired information. Improper categorization of data may mislead the students searching the library. Since manual categorization of huge amount of data might be challenging, an automatic and reliable method is needed. In this sense, this paper proposes an automated categorization scheme for digital libraries in distance learning. The categorization scheme is designed and developed by a pattern recognition approach. Effectiveness of the proposed scheme is evaluated on widely used Reuters database. The results of the ...
2008-10-01
Metadata aggregation and "automated digital libraries": A retrospective on the NSDL experience
Over three years ago, the Core Integration team of the National Science Digital Library (NSDL) implemented a digital library based on metadata aggregation using Dublin Core and OAI-PMH. The initial expectation was that such low-barrier technologies would be relatively easy to automate and administer. While this architectural choice permitted rapid deployment of a production NSDL, our three years of experience have contradicted our original expectations of easy automation and low people cost. We have learned that alleged "low-barrier" standards are often harder to deploy than expected. In this paper we report on this experience and comment on the general cost, the functionality, and the ultimate effectiveness of this architecture.
2006-01-01
Landscapes are both a synthesis and an expression of national, regional and local cultural heritages. It is therefore very important to develop techniques aimed at cataloguing and archiving their forms. This paper discusses the LDL (Landscape Digital Library) project, a Web accessible database that can present the landscapes of a territory with documentary evidence in a new format and from a new perspective. The method was tested in a case study area of the river Po valley (Northern Italy). The LDL is based on a collection of photographs taken following a systematic grid of survey points identified through topographic cartography; the camera level is that of the human eye. This methodology leads to an innovative landscape archive that differs from surveys carried out through aerial photographs or campaigns aimed at selecting "relevant" points of interest. Further developments and possible uses of the LDL are also discussed.
2001-01-01
Fundamental concepts of digital image processing
The field of a digital-image processing has experienced dramatic growth and increasingly widespread applicability in recent years. Fortunately, advances in computer technology have kept pace with the rapid growth in volume of image data in these and other applications. Digital image processing has become economical in many fields of research and in industrial and military applications. While each application has requirements unique from the others, all are concerned with faster, cheaper, more accurate, and more extensive computation. The trend is toward real-time and interactive operations, where the user of the system obtains preliminary results within a short enough time that the next decision can be made by the human processor without loss of concentration on the task at hand. An example of this is the obtaining of two-dimensional (2-D) computer-aided tomography (CAT) images. A medical decision might be made while the patient is still under ...
1983-03-01
Creating Virtual Collections in Digital Libraries: Benefits and Implementation Issues.
Explicitly defining virtual collections in a digital library can benefit both users and contributors. This paper outlines the costs and benefits for defining virtual collections and describes an implementation of collection-level metadata in two digital libraries. Our work suggests that component repositories of NSDL would profit by describing their collection, and sub-collections, using a schema such as the one we implemented. This would enable NSDL to provide a rich, cross-linked hierarchy of virtual collections. By sharing collection-level, rather than item-level, metadata, collections would provide detailed resource information, presumably keeping most of their viewership, while NSDL would provide a broad description of resources.
2003-03-18
Characterizing errors in digital elevation models and estimating the financial costs of accuracy
British Library Electronic Table of Contents (United Kingdom)
Digital topographic models are the foundation of more advanced modeling applications and ultimately inform planning and decision making in many fields. Despite this, the error associated with these models and derived attributes is commonly overlooked. Little attention has been given in the scientific literature to the benefits gained from having less error in a model or to the corresponding cost associated with reducing model error by choosing one product over another. To address these gaps in knowledge we evaluated the error associated with five digital elevation models (DEMs) and derived attributes of slope and aspect relative to the same attributes derived from LiDAR data. We also estimated the acquisition and processing costs per square kilometer of the five test models and the LiDAR m...
2010-01-01
A digitization and multimedia project at Quinnipiac University, Hamden, Connecticut, USA
British Library Electronic Table of Contents (United Kingdom)
Purpose - The purpose of this paper is to encourage other libraries to provide access to their own original content via the web. By way of case study, the process of identifying materials, scanning them and creating web access to original content will be explored. Design/methodology/approach - To implement a book digitization project, three major things need to be present. The library must own material that was published prior to 1923, making them safely out of copyright in the USA; the library needs access to server space on the web and the library needs to own scanning equipment. Findings - This project demonstrated that a library does not necessarily need to obtain grant funding to begin an effective and successful digitization program. It also revealed a few things that would improve t...
2007-01-01
International Nuclear Information System (INIS)
Computed tomography (CT) of the neck and mediastinum was performed in 16 patients with renal osteodystrophy. Thirty out of 34 excised parathyroid glands weighing more than 500mg were diagnosed preoperatively (88.2%). Scintigraphy of the neck with _2_0_1TlCl and sup(99m)TcOsub(4-) was also performed in 15 patients. The introduction of subtraction method with a mini-computor in the scintigraphy has remarkably improved the visualization rate of parathyroid glands. Ultrasonic echography (US) of the neck which is able to obtain not only transverse butalso longitudinal imaging was done in 7 patients. It has about same detection rate of the glands with CT. The visualization of enlarged parathyroid glands is valuable not only for localization but also for undeniable evidence of hyperparathyroidism. Also, repeated follow-up examination can determine the effectiveness of conservative treatment. (author).
Power spectrum calculation for the Cornell Wiggler A SASE experiment at BNL
Energy Technology Data Exchange (ETDEWEB)
Recently, we showed (Yu, Phys. Rev. E 58 (1998) 4991) that the widely used simulation code TDA3D, even though a single-frequency code, can be used to determine the power spectrum in the SASE process with excellent approximation in the exponential growth regime. In this paper, we apply this method to the BNL Cornell Wiggler A SASE experiment as an example. When the gain is not very high, there are many modes in the radiation, which seems to make the analytical calculation very difficult. However, we show that the increment of the radiation due to SASE over the spontaneous radiation can be expanded in terms of guided modes with rapid convergence. Thus when the spontaneous radiation is subtracted from the SASE power during the calculation, there is a good agreement between the analytical theory and the numerical simulation.
1999-06-01
Energy Technology Data Exchange (ETDEWEB)
The authors have made new and improved measurements of the neutron capture and total cross sections of {sup 88}Sr at the Oak Ridge Electron Linear Accelerator (ORELA). Improvements over previous measurements include a wider incident neutron energy range, the use of metallic rather than carbonate samples, better background subtraction, reduced sensitivity to sample-dependent backgrounds, and better pulse-height weighting functions. Because of its small cross section, the {sup 88}Sr(n,{gamma}) reaction is an important bottleneck during the s-process nucleosynthesis. Hence, an accurate determination of this rate is needed to better constrain the neutron exposure in s-process models and to more fully exploit the recently discovered isotopic anomalies in certain meteorites. They describe the experimental procedures, compare the results to previous data, and discuss their astrophysical impact.
1998-11-01
British Library Electronic Table of Contents (United Kingdom)
The total photoabsorption cross section on a free proton was measured at the GRAAL facility in the energy range E ? = 600?1500 MeV. The large-aperture LAGRAN?E detector and a liquid hydrogen target were used in the experiment performed with a back-scattered Compton gamma beam. To improve the accuracy, two alternative methods were employed. First, a subtraction method of using empty-target measurements allowed the cross section ? tot to be evaluated directly because of a low level of the electromagnetic background. Second, an algorithm for evaluating ? tot on the basis of summing the dominating partial cross sections was developed. Experimental results obtained for ? tot by the two methods are compared with existing data.
2008-01-01
Image diagnosis of parathyroid glands in chronic renal failure
Energy Technology Data Exchange (ETDEWEB)
Twenty-two out of 31 patients with chronic renal failure and secondary hyperparathyroidism who underwent parathyroidectomy before operation underwent non-invasive image diagnosis of parathyroid glands by computed tomography (CT), scintigraphy with /sup 201/TlCl and /sup 99m/TcO/sup 4 +/, and/or ultrasonography. CT visualized 39 of 45 parathyroid glands (86.7%), weighing more than 500 mg. Scintigraphy with a subtraction method using a computer performed the diagnosis in 19 of 27 glands (70.4%). Ultrasonography detected 21 of 27 glands (77.8%). Image diagnosis was also useful in the postoperative follow-up study. The non-invasive image diagnosis of parathyroid glands in patients with chronic renal failure is thus valuable for 1) definite diagnosis of secondary hyperparathyroidism, 2) localization, and 3) diagnosis for effectiveness of conservative treatment.
1983-07-01
Hybrid Camera Surveillance System Using Robust Human Detection
We propose a novel surveillance system that uses hybrid camera network. The system contains a panorama camera and PTZ cameras to take the wide range images and face images at high enough resolution for identification tasks. The robust human detection methods include robust background subtraction method (RRC), skin color segmentation and face tracking method. First, the system detects persons from a panorama image, and then the detailed face images are obtained with the PTZ cameras. The PTZ cameras can track the faces using the four directional features and the relaxation matching. In addition, the system has automatic camera position calibration feature. Thus, the user can use the system without any troublesome settings.
2007-01-01
Feedwater control device for a reactor
International Nuclear Information System (INIS)
Purpose: To eliminate the water level deviation due to the recycling flowrate, as well as enable a stable control to a reference value even upon changes in the recycling flowrate caused by the variation in the opening degree of a minimum flow valve. Constitution: Reactor recycling system comprises a feedwater pump, a flowrate control valve, a reactor water level detector, and a minimum flow line and a minimum flow valve for preventing the overheating of the feedwater pump at a low flowrate. A flowrate compensator is further disposed, in which a recycling flowrate signal is subtracted from a pump flow rate signal and the result is fedback as a compensated pump flowrate signal. This enables the control system to operate at a rapid response for suppressing the effect of the recycling flowrate as external disturbance, whereby the water level in the reactor can be controlled stably to the reference level and the possibility deviating from an allowable range is decreased ...
1981-11-18
Energy Technology Data Exchange (ETDEWEB)
We discuss the renormalisation properties of the complete set of {delta}B=2 four-quark operators with the heavy quark treated in the static approximation. We elucidate the role of heavy quark symmetry and other symmetry transformations in constraining their mixing under renormalisation. By employing the Schroedinger functional, a set of non-perturbative renormalisation conditions can be defined in terms of suitable correlation functions. As a first step in a fully non-perturbative determination of the scale-dependent renormalisation factors, we evaluate these conditions in lattice perturbation theory at one loop. Thereby we verify the expected mixing patterns and determine the anomalous dimensions of the operators at NLO in the Schroedinger functional scheme. Finally, by employing twisted-mass QCD it is shown how finite subtractions arising from explicit chiral symmetry breaking can be avoided completely. (Orig.)
2006-04-15
A comparison between steam injection cycle and combined cycle by energy balance
International Nuclear Information System (INIS)
This paper reports on steam injection cycle which is similar to supplementary fired combined cycle, but for the utilized steam medium produced by HRSG, its temperature is higher and pressure is lower than in the combined cycle. In comparison with the thermodynamic advantage of the two cycles, a clear understanding of physical concept can be gotten simply by energy balance. The difference of total power output between them is subtraction of enthalpy difference of exhaust steam and feed water of HRSG in steam injection cycle from the rejected heat by water coolant of condenser in combined cycle, when using the identical gas turbine and the same amount of total fuel consumption. In general case, formulas and data are given to indicate this comparison by the ratio of steam mass flow supplied by HRSG of the two cycles. The analysis of Cheng Cycle Series 7 is applied as an example to give the practical result.
1989-06-05
United States Geological Survey (USGS) FM cassette seismic-refraction recording system
Energy Technology Data Exchange (ETDEWEB)
In this two chapter report, instrumentation used to collect seismic data is described. This data acquisition system has two parts: (1) portable anolog seismic recorders and related ``hand-held-testers`` (HHT) and (2) portable digitizing units. During the anolog recording process, ground motion is sensed by a 2-Hz vertical-component seismometer. The voltage output from the seismometer is split without amplification and sent to three parallel amplifier circuit boards. Each circuit board amplifiers the seismic signal in three stages and then frequency modulates the signal. Amplification at the last two stages can be set by the user. An internal precision clock signal is also frequency modulated. The three data carrier frequencies, the clock carrier frequency, and a tape-speed compensation carrier frequency are summed and recorded on a recorded on a cassette tape. During the digitizing process, the cassette tapes are played back and the signals are ...
1988-12-31
Swift Science Center - HEASARC - NASA
Apr 20, 2009 ... "YY" is the 2-digit filter identifier .... In our example you can see a point- like optical/UV source in each of the filters at the ... The "sigma" paramter gives the detection threshold in terms of Gaussian sigma. ...
Destress blasting is commonly used as a stress control technique at the Galena Mine, Wallace, Idaho, where the U.S. Bureau of Mines maintains a cooperative research program with the mine operators (ASARCO). A digital seismic array and an array of borehole...
1993-01-01
SEER Treatment Field Names, Edition Numbers, NAACCR Data Item Name,
In addition, for breast cancer, a fifth field, Reconstruction--First Course is recorded. V.02.E Reconstruction--First Course (breast only) 1 digit These codes for these fields are included as Appendix C of this manual.
Robust parameter extraction for decision support using multimodal intensive care data
UK PubMed Central (United Kingdom)
Digital information flow within the intensive care unit (ICU) continues to grow, with advances in technology and computational biology. Recent developments in the integration and archiving of these...Full Text Available
2009-01-28
Remote control monitoring - a review of the latest equipment
Energy Technology Data Exchange (ETDEWEB)
This article reviews briefly a range of the latest monitoring and controlling equipment for use in coal mines. This includes pressure transmitters, shale/coal discriminator, nucleonic bunker level indicator, automatic steering and monitoring system, oscilloscope/multimeter, and microprocessor based digital display controllers. 1 fig.
1988-01-01
Purpose: The present research aims to identify the difficulties and obstacles for developing digital libraries in the seven regional branches of Islamic Azad University (IAU), Iran, and to study the status of librarians' skills and education programmes at these institutions. Design/methodology/approach: The 40 individuals working in the regional branch libraries of IAU were surveyed by a questionnaire consisting of 34 questions, and the collected data were analysed using SPSS software (version 16). Findings: It was found that the most important difficulties are the lack of suitable equipment and untrained personnel (i.e. a lack of sufficient training programmes). Research limitations/implications: Because of the small number of participants, it is suggested that a larger scale study is carried out. It is also proposed that the suggestions made by the participants will be considered and implemented, based on the digital library (DL) developments ...
2010-12-01
Ontario Timber Inventory (OTI) Level-I Digital Data - NASA
Abstract: Data currently available in the Ontario Timber Inventory include Canada ... Download 1:250 000 scale Ontario Timber Inventory data in Arc Export ...
No short-term effects of digital mobile radio telephone on the awake human electroencephalogram
Energy Technology Data Exchange (ETDEWEB)
A recent study reported the results of an exploratory study of alterations of the quantitative sleep profile due to the effects of a digital mobile radio telephone. Rapid eye movement (REM) was suppressed, and the spectral power density in the 8--13 Hz frequency range during REM sleep was altered. The aim of the present study was to illuminate the influence of digital mobile radio telephone on the awake electroencephalogram (EEG) of healthy subjects. For this purpose, the authors investigated 34 male subjects in a single-blind cross-over design experiment by measuring spontaneous EEGs under closed-eyes condition from scalp positions C{sub 3} and C{sub 4} and comparing the effects of an active and an inactive digital mobile radio telephone (GSM) system. During exposure of nearly 3.5 min to the 900 MHz electromagnetic field pulsed at a frequency of 217 Hz and with a pulse width of 580 {micro}s, the authors could not detect ...
1997-05-01
NASA Surfs the Skies Above Oahu, Hawaii
National Aeronautics and Space Administration (NASA)
This flyover of the Hawaiian island of Oahu was made by draping Jan. 13, 2010, image data from the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) instrument on NASA's Terra spacecraft over new ASTER Version 2 digital elevation data.
2011-10-17
UK PubMed Central (United Kingdom)
BackgroundPhysicians have difficulty keeping up with new evidence from medical research.MethodsWe developed the McMaster Premium...Full Text Available
2006-11-01
JAtlasView: a Java atlas-viewer for browsing biomedical 3D images and atlases
UK PubMed Central (United Kingdom)
BackgroundMany three-dimensional (3D) images are routinely collected in biomedical research and a number of digital atlases with associated anatomical and other information have...Full Text Available
Integration of turbo-generator modules in digital transient network analyzer
The behavior of a small power system consisting of two interconnected generators is simulated in real-time by a prototype Digital Transient Network Analyzer (TNA). The prototype Digital TNA consists of two Computational Modules and one I/O Module. The Modules communicate with each other through ribbon cables. Each Computational Module simulates one Turbo-Generator, its Transformer, its Governor, Exciter, and Power System Stabilizer Systems. The numerical integration is shared by two TMS320C30 DSPs at a step-size of 100 microseconds in real-time. The I/O module post-processes the state variables and presents selected information for analog display. The paper presents oscillograms from a test program which includes symmetry checks and behavioral checks against well known waveforms of hunting oscillations, synchronization out-of-phase torques, and subsynchronous resonance phenomena. The success of the Digital TNA depends on: ...
1994-05-01
UK PubMed Central (United Kingdom)
This paper describes Image Engine, an object-oriented, microcomputer-based, multimedia database designed to facilitate the storage and retrieval of digitized biomedical still images, video, and text...Full Text Available
1993-01-01
International Nuclear Information System (INIS)
This talk sketches out the main parameters (technology, circuit design) that have an influence on the hardening of digital CMOS integrated circuits. For each technology the more common defects are mentioned. General design rules are proposed to prevent or limit those defects. (D.L.). 2 refs., 2 figs.
Digital Talking Books: Planning for the Future.
Ever-changing audio technology requires that National Library Service NLS always be aware of developments and prepare carefully for any systematic changes that may be desired or required. Usefulness, cost effectiveness, thoughtful stewardship, and educate...
1998-01-01
Classification of hematologic malignancies using texton signatures
UK PubMed Central (United Kingdom)
We describe a decision support system to distinguish among hematology cases directly from microscopic specimens. The system uses an image database containing digitized specimens from normal...Full Text Available
2007-10-01
Calcium gradients and buffers in bovine chromaffin cells.
UK PubMed Central (United Kingdom)
1. Digital imaging and photometry were used in conjunction with the fluorescent Ca2+ indicator, Fura-2, to examine intracellular Ca2+ signals produced by depolarization of single adrenal chromaffin...Full Text Available
1992-05-01
Automatic scene-adaptive pattern removal
Energy Technology Data Exchange (ETDEWEB)
A new method for removing periodic background patterns from pictures is presented. The basic spatial frequency composition of the pattern is determined from an estimate of the power spectrum of the picture. A digital restoration filter is then created from a modified version of the power spectrum. The method is extremely effective and can be automated.
1982-01-01
Acceptance testing in digital systems of mammography. Protocols applicability
International Nuclear Information System (INIS)
Acceptance testing of mammographic imaging systems technical is the first approach in order to guarantee that mammograms will be achieved with the minimum radiation dose compatible with an image quality suitable for diagnose purposes. The aim of this study is to assess the practical applicability of different protocols in acceptance test of digital mammographic systems. This study has been carried out on the results of the acceptance tests of five flat panel digital mammographic systems. Parameters established in the systems technical specifications and those evaluated in the consulted protocols were tested. Due to the fact that the legislation in our country does not demand to consider a specific protocol, the results obtained were also compared considering different existing protocols. Results show discrepancies between manufacturers limiting values and those established in the protocols. Some parameters, such as the automatic exposure ...
A high-speed network for cardiac image review.
UK PubMed Central (United Kingdom)
A high-speed fiber-based network for the transmission and display of digitized full-motion cardiac images has been developed. Based on Asynchronous Transfer Mode (ATM), the network is scaleable, meaning...Full Text Available
1994-01-01
Long-term preventive maintenance of instrumentation control equipment for PWR plants
International Nuclear Information System (INIS)
Since the PWR plants in Japan have been operated more than 30 years, main instrumentation control equipment of analog systems has been renewed to digital control systems. Renewal works had to be done in short period within periodical inspection term and for several facilities. The Mitsubishi LTD group had been provided with these market needs by its digital control system (MELTAC-NplusR 3) applicable to main instrumentation control equipment for primary and secondary systems and had already finished the renewal for practical plants. (T. Tanaka)
2006-02-01
International Nuclear Information System (INIS)
The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)
2004-04-01
IQARIS : a tool for the intelligent querying, analysis, and retrieval from information systems.
Energy Technology Data Exchange (ETDEWEB)
Information glut is one of the primary characteristics of the electronic age. Managing such large volumes of information (e.g., keeping track of the types, where they are, their relationships, who controls them, etc.) can be done efficiently with an intelligent, user-oriented information management system. The purpose of this paper is to describe a concept for managing information resources based on an intelligent information technology system developed by the Argonne National Laboratory for managing digital libraries. The Argonne system, Intelligent Query (IQ), enables users to query digital libraries and view the holdings that match the query from different perspectives.
2002-04-26
HVDC cable design logic for digital computers
Energy Technology Data Exchange (ETDEWEB)
The design of High-Voltage, Direct-Current transmission cables insulated with oil-impregnated cellulose paper is constrained by the maximum temperature and the maximum steady-state and transient stresses (voltage gradients) that the cable insulation can reliably withstand over the desired operating lifetime. Because the electrical stresses in the insulation are related in a very complex fashion to temperature, applied voltage and cable geometry, iterative techniques are required to compute the values of these stresses. Digital computers are ideally suited for these iterative techniques. This paper presents the principal equations and logic needed to develop suitable computer programs.
1992-10-01
Energy Technology Data Exchange (ETDEWEB)
A typical incident response pits technicians against networks that aren't prepared forensically. [1, 2] If practitioners do consider collecting network forensic data, they face a choice between expending extraordinary effort (time and money) collecting forensically sound data, or simply restoring the network as quickly as possible. In this context, the concept of organizational network forensic readiness has emerged. This paper proposes a methodology for "operationalizing" organizational network forensic readiness. The methodology, and the theoretical analysis that led to its development, are offered as a conceptual framework for thinking about more efficient, proactive approaches to digital forensics on networks.
2006-08-01
Energy Technology Data Exchange (ETDEWEB)
We performed a comparative study of digitally and conventionally acquired images in gastrointestinal examinations. Radiation dose and spatial resolution were determined in a water phantom. In 676 examinations with either conventional or digital imaging (system: Diagnost 76, DSI) the number of images and the duration of the fluoroscopy time were compared. 101 examinations with digital as well as conventional documentation were evaluated by using 5 criteria describing the diagnostic performance. The entrance dose of the DSI is 12% to 36% of the film/screen system and the spatial resolution of the DSI may be better than that of a film/screen system with a speed of 200. The fluoroscopy time shows no significant difference between DSI and the film/screen technique. In 2 of 4 examination modes significantly more images were produced by the DSI. With exception of the criterion of edge sharpness, DSI yields a significantly inferior ...
1995-10-01
Computer system architecture. Second edition
Energy Technology Data Exchange (ETDEWEB)
A register transfer language is used to present the basic concepts of computer hardware architecture. Material needed for understanding computer organisation, design, and programming is included. The various functional units of digital computers (central processor, microprogram control; arithmetic algorithms; input-output; and memory organisation), are examined. A basic computer is developed to demonstrate the components of computer hardware and software architecture. Parallel processing and multiprocessor systems are discussed. Numerous MSI and LSI digital functions are introduced with explanations of their characteristics. Cache memory and the hardware requirements for a memory management unit are covered.
1982-01-01
Energy Technology Data Exchange (ETDEWEB)
Use of a broadband Local Area Network (LAN) for transmission of classified and secure unclassified information requires monitoring capabilities which are sensitive to discrete segments of the network frequency spectrum. A viable monitoring system must be capable of detecting possible intrusion attempts or network malfunctions and alerting operating and security personnel. This report documents the results of an evaluation of the Magnavox CATV Systems Inc. Digital System Sentry software for network monitoring. Recommendations are made on its possible future role in broadband LAN security monitoring throughout the Nuclear Weapons Complex.
1991-01-01
Application of the digital waveform analysis to Bragg curve spectrometer
International Nuclear Information System (INIS)
Energy and angular double-differential cross-section (DDX) data of fragment production reactions by neutrons or protons are very scarce due to experimental difficulties of fragment detection. We adopted a Bragg curve spectrometer (BCS), which is a gridded-ionization chamber that can identify fragments on the basis of the Bragg peak value. We have been developing the BCS for neutron and proton-induced reactions applying the digital waveform analysis technique to obtain better ability of particle discrimination than the analog electronic circuit. (T. Tanaka)
2004-11-01
Energy Technology Data Exchange (ETDEWEB)
In relation to considerations on composition of gas produced by coal gasification, the HYCOL hydrogen generation process data were analyzed. From the fact that CO concentration (Y) decreases linearly with CO2 concentration (X), element balance of gasification of reacted coal was used to introduce a reaction analysis equation. The equation includes a term of oxygen excess {Delta}(amount of oxygen consumed for combustion of CO and H2 in excess of the theoretical amount), derived by subtracting the stoichiometric oxygen amount used to gasify coal into CO and H2 from the consumed oxygen amount. The {Delta} can be used as a reference to oxygen utilization efficiency. An equation for the {Delta} was introduced. Also introduced was a term for steam decomposition amount derived by subtracting the generated steam from the supplied steam. These terms may be used as a clue to permeate into the gasifying reaction process. This suggestion was discussed by ...
1996-10-28
Energy Technology Data Exchange (ETDEWEB)
A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above mentioned image processings are adopted, FCR can be used for the diagnosis of ...
1993-06-01
The application of the Fuji Computed Radiography system for the diagnosis of pneumoconiosis
International Nuclear Information System (INIS)
A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above mentioned image processings are adopted, FCR can be used for the diagnosis of ...
1993-01-01
Radiation hardening of CMOS-based circuitry in SMART transmitters
International Nuclear Information System (INIS)
Process control transmitters that incorporate digital signal processing could be used advantageously in nuclear power plants; however, because such transmitters are too sensitive to radiation, they are not used. The Electric Power Research Institute sponsored work at Sandia National Laboratories under EPRI contract RP2614-58 to determine why SMART transmitters fail when exposed to radiation and to design and demonstrate SMART transmitter circuits that could tolerate radiation. The term ''SMART'' denotes transmitters that contain digital logic. Tests showed that transmitter failure was caused by failure of the complementary metal oxide semiconductors (CMOS)-integrated circuits which are used extensively in commercial transmitters. Radiation-hardened replacements were not available for the radiation-sensitive CMOS circuits. A conceptual design showed that a radiation-tolerant transmitter could be constructed. A prototype for an ...
International Nuclear Information System (INIS)
The purpose of this study is to investigate the possibility of verifying depleted uranium (DU), natural uranium (NU), low enriched uranium (LEU) and high enriched uranium (HEU) by a developed digital gamma-gamma coincidence spectroscopy. The spectroscopy consists of two NaI(Tl) scintillators and XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The results demonstrate that the spectroscopy provides an effective method of "2"3"5U and "2"3"8U quantification based on the count rate of their gamma-gamma coincidence counting signatures. The main advantages of this approach over the conventional gamma spectrometry include the facts of low background continuum near coincident signatures of "2"3"5U and "2"3"8U, less interference from other radionuclides by the gamma-gamma coincidence counting, and region-of-interest (ROI) imagine analysis for uranium enrichment determination. Compared to conventional gamma spectrometry, the method ...
2011-06-01
The hurried development of multimedia and internet allows for wide distribution of digital media data. It becomes much easier to edit, modify and duplicate digital information. In additional, digital document is also easy to copy and distribute, therefore it may face many threats. It became necessary to find an appropriate protection due to the significance, accuracy and sensitivity of the information. Furthermore, there is no formal method to be followed to discover a hidden data. In this paper, a new information hiding framework is presented.The proposed framework aim is implementation of framework computation between advance encryption standard (AES) and distortion technique (DT) which embeds information in image page within executable file (EXE file) to find a secure solution to cover file without change the size of cover file. The framework includes two main functions; first is the hiding of the information in the ...
2009-01-01
Interim cryo-cooler/detector report
Energy Technology Data Exchange (ETDEWEB)
This report describes development of an electronic system designed to reduce vibration generated by a cryocooler. The diminished vibration makes it practical to use the active cooler to extract heat from a portable gamma ray detector instrument. The system was developed for a Sunpower cryocooler with an integrated counterbalance mass. The overall momentum cancellation approach is also applicable to other similar cryocoolers. The cancellation system is an assembly of several components tailored to accomplish the required vibration reduction with minimum power consumption and volume. It is designed to be powered by a 18--32 Volt battery. Up to ten harmonics of the 58.65 Hz drive frequency are controlled. In addition to the vibration cancellation, the electronic system produces the drive signal for the cryocooler and regulates the cooler temperature. The system employs a sinusoidal drive to reduce the amount of higher harmonic vibration. A digital signal processor ...
1995-04-19
IGENPRO knowledge-based digital system for process transient diagnostics and management
Energy Technology Data Exchange (ETDEWEB)
Verification and validation issues have been perceived as important factors in the large scale deployment of knowledge-based digital systems for plant transient diagnostics and management. Research and development (R&D) is being performed on the IGENPRO package to resolve knowledge base issues. The IGENPRO approach is to structure the knowledge bases on generic thermal-hydraulic (T-H) first principles and not use the conventional event-basis structure. This allows for generic comprehensive knowledge, relatively small knowledge bases and above all the possibility of T-H system/plant independence. To demonstrate concept feasibility the knowledge structure has been implemented in the diagnostic module PRODIAG. Promising laboratory testing results have been obtained using data from the full scope Braidwood PWR operator training simulator. This knowledge structure is now being implemented in the transient management module PROMANA to treat unanticipated events and ...
1997-12-31
International Nuclear Information System (INIS)
Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly different. Conclusion: The image quality of direct digital radiography system is improved as the exposure dose increases, and as the ...
2005-10-01
Comparison of digital and analogue data acquisition systems for nuclear spectroscopy
International Nuclear Information System (INIS)
In the present investigation the performance of digital data acquisition (DA) and analogue data acquisition (AA) systems are compared in neutron-induced fission experiments. The DA results are practically identical to the AA results in terms of angular-, energy- and mass-resolution, and both compare very well with literature data. However, major advantages were found with the digital techniques. DA allows for a very efficient #alpha#-particle pile-up correction. This is important when considering the accurate measurement of fission-fragment characteristics of highly #alpha#-active actinide isotopes relevant for the safe operation of Generation IV reactors and the successful reduction of long-lived radioactive nuclear waste. In case of a strong #alpha#-emitter, when applying the #alpha#-particle pile-up correction, the peak-to-valley ratio of the energy distribution was significantly improved. In addition, DA offers a very flexible expanded ...
2010-12-21
Application of imaging plate technology for NDT; Imaging plate gijutsu to sono oyo
Energy Technology Data Exchange (ETDEWEB)
This paper describes Fuji computed radiography (FCR) of Fuji Film for NDT (non-destructive testing). Imaging plate (IP) is a two-dimensional detector of X-ray, and shows higher photographic sensitivity than X-ray film. The output emission of IP provides a good linear relationship to X-ray intensity in a wide intensity range. When this emission can be digitized, the X-ray intensity can be also digitized. IP is applied to NDT as an inspection using X-ray. FCR provides higher photographic sensitivity than the conventional X-ray film method, which results in one-fifth to one-twentieth of irradiation time. Images with stable density can be obtained independent of the intensity. Since IP has a wide dynamic range, the variation of X-ray intensity of 1:500 can be expressed in a single image by single shot. High density record including 1000 images can be done using a 5.25 inch optical disk through the digital image processing and ...
1998-10-01
A systematic search for novae in M31 on a large set of digitized archival Schmidt plates
This paper reports on the detection of optical novae in our neighbour galaxy M31 based on digitized historical Tautenburg Schmidt plates. The accurate positions of the detected novae lead to a much larger database for searches for recurrent novae in M31. We conducted a systematic search for novae on 306 digitized Tautenburg Schmidt plates covering a time span of 36 years from 1960 to 1996. From the database of both ~ 300 000 light curves and about one million detections on only one plate per colour band, nova candidates were efficiently selected by automated algorithms and subsequently individually inspected by eye. We report the detection of 84 nova candidates. In detail we found 55 nova candidates from the automated analysis of the light curves. Among these, 22 were previously unknown, 12 were known but have not been identified on Tautenburg Schmidt plates before and 21 novae have been discovered on Tautenburg plates previously. An additional ...
2007-01-01
The Benchmark Test Results of QNX RTOS
International Nuclear Information System (INIS)
A Real-Time Operating System(RTOS) is an Operating System(OS) intended for real-time applications. Benchmarking is a point of reference by which something can be measured. The QNX is a Real Time Operating System(RTOS) developed by QSSL(QNX Software Systems Ltd.) in Canada. The ELMSYS is the brand name of commercially available Personal Computer(PC) for applications such as Cabinet Operator Module(COM) of Digital Plant Protection System(DPPS) and COM of Digital Engineered Safety Features Actuation System(DESFAS). The ELMSYS PC Hardware is being qualified by KTL(Korea Testing Lab.) for use as a Cabinet Operator Module(COM). The QNX RTOS is being dedicated by Korea Atomic Energy Research Institute (KAERI). This paper describes the outline and benchmarking test results on Context Switching, Message Passing, Synchronization and Deadline Violation of QNX RTOS under the ELMSYS PC platform
2010-10-01
Revisited the mathematical derivation wall thickness measurement of pipe for radiography
Energy Technology Data Exchange (ETDEWEB)
Wall thickness measurement of pipe is very important of the structural integrity of the industrial plant. However, the radiography method has an advantage because the ability of penetrating the insulated pipe. This will have economic benefit for industry. Moreover, the era of digital radiography has more advantages because the speed of radiographic work, less exposure time and no chemical used for film development. Either the conventional radiography or digital radiology, the wall thickness measurement is using the tangential radiography technique (TRT). In case, of a large diameter, pipe (more than inches) the determination maximum penetration wall thickness must be taken into the consideration. This paper is revisited the mathematical derivation of the determination of wall thickness measurement based on tangential radiography technique (TRT). The mathematical approach used in this derivation is the Pythagoras theorem and geometrical ...
2007-07-01
REVIEW: Optical waveguide processors
An analysis is made of the basic principles and methods of construction of integrated optical circuits (IOC) for data processing, which are optical waveguide processors in the integrated form. A classification is provided of IOC in accordance with the nature of the input connections to optical components and in accordance with their intended function. An analysis is made of the current status of research and development of analog IOC for handling analog and digital signals, IOC for computing technology, and switching IOC. A detailed analysis is made of IOC with different functions in data processing: spectrum analyzers and correlators, analog-digital converters, circuits for identification of data sets and for encoding of signals, threshold and multistable circuits, logic and arithmetic units, and switching arrays. Descriptions are given of IOC for optically controlled data handling: bistable purely optical logic circuits, multivibrators, ...
1987-07-01
Normalized noise power spectrum of full field digital mammography detector system
International Nuclear Information System (INIS)
Full text: A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through de trending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (author)
Normalized Noise Power Spectrum of Full Field Digital Mammography System
International Nuclear Information System (INIS)
A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality.
2010-01-05
We present a new modular traffic signs recognition system, successfully applied to both American and European speed limit signs. Our sign detection step is based only on shape-detection (rectangles or circles). This enables it to work on grayscale images, contrary to most European competitors, which eases robustness to illumination conditions (notably night operation). Speed sign candidates are classified (or rejected) by segmenting potential digits inside them (which is rather original and has several advantages), and then applying a neural digit recognition. The global detection rate is ~90% for both (standard) U.S. and E.U. speed signs, with a misclassification rate 150 minutes of video. The system processes in real-time ~20 frames/s on a standard high-end laptop.
2009-01-01
Measurement of dynamic fracture toughness and failure behavior for explosive mock materials
British Library Electronic Table of Contents (United Kingdom)
In this work, a pre-cracked semi-circular shaped explosive simulant was loaded using a split Hopkinson pressure bar (SHPB). A high-speed camera was used to capture the deformation and fracture process of the specimen in situ. The digital images were processed using the digital image correlation (DIC) method. Next, full displacement and strain fields were obtained. The displacement vector field shows that the specimen fractured under tensile stress action. The strain field can be used to predict the crack propagation. Results show that the method of combined DIC and SHPB is effective to study the dynamic deformation and fracture behavior of explosive simulants. In addition, the specimen was loaded using a drop weight. The fracture toughness of the specimen was preliminary measured.
2011-01-01
Instruments for X-ray fluorescence analysis and spectrometry
International Nuclear Information System (INIS)
The radionuclide X-ray fluorescence analyzer consists of a source changer and a sample changer. "5"5Fe, "1"0"9Cd and "2"4"1Am are used as excitation sources. The radiation is detected with a semiconductor Si(Li) detector. The complete assembly of the apparatus consists of an imagine unit, a keyboard, a floppy disc drive, a printer, a console and a rack with analog and digital electronics. Its multichannel amplitude analyzer consists of power supplies, a high voltage supply, a linear amplifier, an analog-to-digital converter and a computer. The technical specifications are given. The control and data processing system is controlled with an MHB 8080A microprocessor. Software for semiconductor gamma spectrometry and for quantitative gamma spectrometry will be supplied with the equipment. (E.S.). 3 figs., 4 refs.
Energy Technology Data Exchange (ETDEWEB)
The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)
2004-04-15
Fundamental aspects of fault location algorithms used in distance protection
Energy Technology Data Exchange (ETDEWEB)
Considers fundamental problems involved in the precise location of faults on high-voltage transmission lines. The influence of pre-fault load on the distance-to-fault measurement problem is analysed and a new method of accounting for load effects is presented. Two of the algorithms considered are precise, containing no simplifyng assumptions and their overall accuracy is limited only by the accuracy of digital impedance relays at both ends of the protected circuit. A third algorithm presents a new approach to the fault location problem, which requires digital impedance relays at one end only of a transmission line. The procedures described are applicable to any system arrangement and are suitable for a wide range of fault resistance values.
1986-09-01
Estimating hip fracture risk from digital x-ray image data
International Nuclear Information System (INIS)
The authors propose a method for determining the risk of femoral neck fracture in osteoporotic patients that is not based on densitometric techniques. The method is based on a structural analysis performed by a computer on data taken from a single digital anteroposterior projection of the hip. From the image, the effective cross-sectional area and cross-sectional moment of inertia are computed from attenuation principles. Together with other geometric measurements, these data are used in an engineering analysis to compute the yield strength of the proximal femur, under stress applied through the acetabulum in a one-legged stance. An index of fracture risk based on the ratio of estimated yield strength to body weight is proposed. Ultimately it is expected that this work will allow the clinician to estimate hip fracture risk in osteoporotic patient using widely available existing technology, a goal which has eluded bone density-based methods.
Document image retrieval with morphology-based segmentation and features combination
Digital libraries need more than just a retrieval based on keywords, which can be inefficient for some applications. Thus, a document retrieval based on content of the digitized image version of the document can be a more appropriated approach. This paper discusses the retrieval of document images by means of identifying a variety of elements present in the document's image body. We propose a new strategy to identify and combine features extracted from a document image. We also consider the task of constructing an optimized feature set to improve the retrieval performance and to validate our experiments on an assorted database. Experimental results show that the proposed segmentation together with a wisely feature combination increase the overall retrieval performance. Moreover the retrieved images demonstrate the generality and effectiveness of our approach for an efficient segmentation and classification of document images.
2011-01-01
Digital Libraries: From Process Modelling to Grid-based Service Oriented Architecture
Graphical Business Process Modelling Languages (BPML) like Role Activity Diagrams (RAD) provide ease and flexibility for modelling business behaviour. However, these languages show limited applicability in terms of enactment over distributed systems paradigms like Service Oriented Architecture (SOA) based grid computing. This paper investigates RAD modelling of a Scientific Publishing Process (SPP) for Digital Libraries (DL) and tries to determine the suitability of Pi-Calculus based formal approaches to enact SOA based grid computing. In order to achieve this purpose, the Pi-Calculus based formal transformation from a RAD model of SPP for DL draws attention towards a number of challenging issues including issues that require particular design considerations for appropriate enactment in a SOA based grid system.
2006-01-01
Correlation between the Individual and the Combined Width of the Six Maxillary Anterior Teeth
British Library Electronic Table of Contents (United Kingdom)
ABSTRACT Purpose: There is a consensus in the community of dental research that the selection of undersized artificial maxillary anterior teeth offers an unnatural appearance to the denture. Several methods to select the adequate width of these teeth are of questionable validity, and many dentures have an obviously artificial appearance. This article assessed the relationship between the individual and the combined width of maxillary anterior teeth. Materials and Methods: Impressions were made of the anterior dentition of 69 dentate undergraduate students with rubber impression silicon, and casts were formed. The individual widths of the maxillary anterior teeth were measured by using a digital caliper (SC-6 digital caliper, Mitutoyo Corporation, Tokyo, Japan), and the combined width was r...
2009-01-01
International Nuclear Information System (INIS)
A consideration is given to the problem of selecting optimized methods of radionuclide radiation registration during the control of the objects with essential changes in thickness. Adequate model of information signal formation is developed and analyzed for the case of the existence of an inertial link of the system with the dead time of a noncontinued type. The boundary values of radiation thickness and radiation flux intensity that divide the priority of using either digital or analog registration modes are revealed. The method is found for the full correction of a systematic error of flux intensity measurement because of the dead time of the apparatus. To control the objects with essential variation of thickness the method of selective measurement of radiation intensity is proposed
Class 1E digital systems studies
International Nuclear Information System (INIS)
This document is furnished as part of the effort to develop NRC Class 1E Digital Computer Systems Guidelines which is Task 8 of USAF Rome Laboratories Contract F30602-89-D-0100. The report addresses four major topics, namely, computer programming languages, software design and development, software testing and fault tolerance and fault avoidance. The topics are intended as stepping stones leading to a Draft Regulatory Guide document. As part of this task a small scale survey of software fault avoidance and fault tolerance practices was conducted among vendors of nuclear safety related systems and among agencies that develop software for other applications demanding very high reliability. The findings of the present report are in part based on the survey and in part on review of software literature relating to nuclear and other critical installations, as well as on the authors' experience in these areas.
An integrating dosimeter for pulsed radiation
A Pulsed Radiation Dosimetry System designed to measure radiation produced by particle accelerators is described. The problems associated with total-dose measurement of irregular shaped pulses of ionizing radiation have been simplified. The system responds to extremely narrow pulses of charged particles or X-rays using a pin diode as the detector. Direct readout of dose in rads (Si) is displayed on a 3-1/2 digit digital panel meter. The system will operate in either the multiple-pulse or single-pulse mode. The multiple-pulse mode would be useful in monitoring or tuning a linear accelerator. In the single-pulse mode the system will automatically display total dose of a transient event in real time and hold that measurement indefinitely or until the next measurement is made. The system features an automatic reset in either mode.
1983-12-01
A study on the comparative method using AHP and GIS based distributed runoff model
British Library Electronic Table of Contents (United Kingdom)
Research in the field of river hydrology has been mainly concerned with the investigation of the rainfall-runoff phenomenon through the analysis of hydrological factors such as meteorology and geography, with the focus being on each river basin. Recently, various forms of digital information such as GIS (Geographic Information System) and RS (Remote Sensing) data have been made available in worldwide digital map format. Therefore, there has been a shift in focus from lumped-parameter models to distributed runoff models, as the latter can consider temporal and spatial variations in water quantity. Distributed runoff models have made possible the comparison of runoff field and rainfall-runoff characteristics considering spatial distribution. Hydrological conditions are differently distribute...
2010-01-01
International Nuclear Information System (INIS)
The tissue distribution of "1"3"1I-transferrin ("1"3"1I-Tf) was studied in athymic nude mice having s.c. human colonic adenocarcinoma HT-29 xenografts. Four days after "1"3"1I-Tf injection, the "1"3"1I specific activity measured in the HT-29 tumor, i.e. amount of radioactivity per gram of fresh tissue, represented 0.31 #+-# 0.09% of the injected radioactivity and was 1.90 fold more than that measured in the murine colon (P < 0.05). After correction for intravascular "1"3"1I-Tf as estimated by mean of "9"9"mTc-Sn in vivo labeling of red blood cells, the "1"3"1I specific activity observed in the HT-29 tumor was 7.21 fold more than that observed in the murine colon. This subtracting method enabled us to localize a HT-29 tumor xenograft by #gamma# scintigraphy of the entire animal and demonstrated that "1"3"1I-Tf could be a non-specific but potent marker for human colon cancer. (author).
The prospects for polarized target materials with pure carbon background
None of the materials presently in common use for polarized proton targets has a pure carbon nuclear background. The alcohols and diols contain some oxygen, and the ammonia and amine-based materials contain nitrogen and/or other noncarbon species. In the latter cases the noncarbon nuclei are measurably polarized as a concomitant of the process used to polarize the hydrogen nuclei. The relative simplicity of a pure carbon background would be advantageous for most types of scattering experiments and perhaps crucial for some. In addition to simplifying the kinematics of background events, pure carbon is relatively easy to prepare as a dummy'' target for background subtraction. Also, in such a target material, [sup 13]C-enrichment would yield a clean polarized [sup 13]C material. In this note I explore the possibilities for such materials, touching upon only what I consider to be the high'' points. The subject matter is capable ...
1992-10-06
British Library Electronic Table of Contents (United Kingdom)
Plant meiotic prophase I is a complicated process involving the late zygotene and pachytene stages, both crucial for completing synapsis and recombination. Using David Lily (Lilium davidii var. Willmottiae) as our research material, we performed suppression subtractive hybridization to construct EST library of anthers at various stages of development by the pollen mother cells. From this library, we identified small heat shock protein LimHSP16.45 was highly expressed during the late zygotene to pachytene stages. Our results also showed that LimHSP16.45 was almost specifically expressed in the anther compared with the root, stem, or leaf, and in situ expression of LimHSP16.45 mRNAs showed strong signals in the pollen mother cells and tapetal cells. LimHSP16.45 could be induced by heat and c...
2011-01-01
Scatter measurements for optical cone-beam computed tomography
Energy Technology Data Exchange (ETDEWEB)
Both x-ray and optical cone-beam CT (CBCT) scanners are limited by scattered photons that contaminate the primary images. Transparent radiochromic gels and plastics are anticipated to produce less scattering than polymerization gels and hence result in reconstructed dose distributions with greater contrast and dynamic range. Four methods of scatter measurement were investigated to quantify scatter fractions using an in-house optical CBCT scanner. The methods consisted of generating either 'coin' shadows or primary beamlets in transmission images. The four methods generated similar results of 10% scatter fractions in gel transmission images for this particular scanner configuration with both leuco crystal violet and carbon black micelle gels. The scatter contributions were distributed as 5% from micelle gel, 2% from Teflon wall, 2% from refractive index matching liquid and 1% other sources. Applying a uniform background subtraction of 2% of open ...
2009-05-01
Renormalizability of the functional Schroedinger picture in Robertson--Walker space-time
Energy Technology Data Exchange (ETDEWEB)
We study free and self-interacting scalar quantum field theories in a flat Robertson-Walker metric in the functional Schroedinger picture. We discuss Schroedinger picture quantization, relating it to conventional Heisenberg picture quantization. For the interacting theory, we introduce the time-dependent Gaussian approximation to study time evolution of pure and mixed states and we establish renormalizability of the approximation. We also study the question of computing a finite, renormalized energy-momentum tensor for both the free and the interacting theory in the Gaussian appproximation. Using the adiabatic expansion, we show that the entire subtration necessary to make the the energy-momentum tensor finite in the free theory can be written in terms of covariantly conserved tensors. We further show that the same subtraction is sufficient to make the energy-momentum tensor finite in the Gaussian approximation for the interacting theory provided that the mass and ...
1989-07-01
International Nuclear Information System (INIS)
The Thomsen-Friedenreich (T) antigen, #betta#-D-Gal-(1->3)-#alpha#-D-GalNAc, is exposed in reactive form on many human adenocarcinomata, but not on corresponding benign tissues. Peanut lectin (PNA) has a strong binding affinity for the T antigen and reportedly binds preferentially to certain malignant tissues. We investigated the potential of radio-labelled PNA as a tumour localising agent in an animal model system using a mouse lymphoma (RI) shown to bind fluorescein-labelled PNA in vitro. The radio-iodinated lectin showed good tumour localisation and rapid blood clearance. Clear images of tumours were obtained, in serial scintigraphic imaging, by 24 and 48 h. No blood background subtraction was necessary. Biodistribution studies revealed tumour to blood ratios in mice were 6:1 (at 24 h) and 17:1 (at 48 h), and tumour to muscle ratios were 34:1 (at 24 h) and 40:1 (at 48 h). Rapid in vivo breakdown of _1_2_5I-PNA led to some localisation of free iodide in the ...
1983-01-01
International Nuclear Information System (INIS)
In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component of a fiber-optic radiation detector and to detect a real fluorescent light signal ...
2007-08-21
Energy Technology Data Exchange (ETDEWEB)
The O({alpha}) electroweak radiative corrections to {gamma}{gamma}{yields}WW{yields}4f within the electroweak standard model are calculated in double-pole approximation (DPA). Virtual corrections are treated in DPA, leading to a classification into factorizable and non-factorizable contributions, and real-photonic corrections are based on complete lowest-order matrix elements for {gamma}{gamma}{yields}4f+{gamma}. Soft and collinear singularities appearing in the virtual and real corrections are combined alternatively in two different ways, namely by using the dipole subtraction method or by applying phase-space slicing. The radiative corrections are implemented in a Monte Carlo generator called Coffer {gamma}{gamma} - the computer code can be obtained from the authors upon request - which optionally includes anomalous triple and quartic gauge-boson couplings in addition and performs a convolution over realistic spectra of the photon beams. A detailed survey of ...
2005-09-01
International Nuclear Information System (INIS)
The O(#alpha#) electroweak radiative corrections to #gamma##gamma##->#WW#->#4f within the electroweak standard model are calculated in double-pole approximation (DPA). Virtual corrections are treated in DPA, leading to a classification into factorizable and non-factorizable contributions, and real-photonic corrections are based on complete lowest-order matrix elements for #gamma##gamma##->#4f+#gamma#. Soft and collinear singularities appearing in the virtual and real corrections are combined alternatively in two different ways, namely by using the dipole subtraction method or by applying phase-space slicing. The radiative corrections are implemented in a Monte Carlo generator called Coffer #gamma##gamma# - the computer code can be obtained from the authors upon request - which optionally includes anomalous triple and quartic gauge-boson couplings in addition and performs a convolution over realistic spectra of the photon beams. A detailed survey of ...
2005-09-01
Energy Technology Data Exchange (ETDEWEB)
This report describes the fiscal 1998 result on development of genome informatics technology. As comparative analysis technique of genes, the combination of electrophoresis and PCR was used. For improvement of the throughput and reproducibility of the technique, module- shuffling primers were used, and the multi(96)-arrayed capillary fragment analyzer was devised. The system detecting SNPs rapidly was also developed successfully. As analysis technology of DNA sequence by use of triple- stranded DNA formation, study was made on construction of long cDNA libraries, selective subtraction of specific sequences from libraries, and the basic technology of homologous cloning. Study was also made on each reaction step of IGCR technique for fast analysis, and specifications of a fluorescence transfer monitor. As modeling technique of genetic sequence information, the simulation model was developed for gene expression regulatory networks during muscle differentiation, and ...
1999-03-01
Energy Technology Data Exchange (ETDEWEB)
The fluxes of atmospheric electrons, positrons, positive and negative muons and negative pions have been determined using the NMSU Wizard-MASS2 balloons-borne instrument. The instrument was launched from Fort Sumner, New Mexico, (geomagnetic cut-off about 4.5 GV/c) on september 23, 1991. The flight lasted 9.8 hours and remained above 100.000 ft. Muons and negative pions were observed and their momenta were determined. Since these particles are not a part of the primary component, the measurement of their fluxes provides information regarding production and propagation of secondary particles in the atmosphere. Similarly, observations of electrons and positrons well below the geomagnetic cut-off provides insight into electromagnetic cascade processes in the upper atmosphere. In addition, the determination of the energy spectra of rare particles such as positrons can be used for background subtraction for cosmic ray experiments gathering data below a few g/cm{sup 2} ...
1995-09-01
Energy Technology Data Exchange (ETDEWEB)
Stainless steel is pickled in pickling bath with the sulfuric acid and a mixture of hydrofluoric acid and nitric acid. Suitable equipment based on speedy and accurate chemical analysis for actual production lines has not been developed yet. The concentration of sulfuric acid can be analyzed by using the neutralization titration method. As a method of analyzing hydrofluoric acid in the mixed acid, the iron-acetylacetone complex discoloration absorbance method was adopted. For the concentration, of nitric acid, the method of subtracting the concentration of hydrofluoric acid from the total mixed acid amounts obtained by neutralization titration is adopted. Furthermore, the iron-salicylic acid complex absorbance method is adopted as a method of analyzing the iron content. By adopting these methods, the fully automated analyzer is developed. Completing analysis work can be shortened to 40 minutes by automated sampling from the acid pipes. The fully automated acid ...
1999-01-10
Clinical trial of NMR-CT, (4). Clinical evaluation of hybrid image
Energy Technology Data Exchange (ETDEWEB)
In our evaluation we utilized the Asahi Mark-J NMR-CT system, with a resistive vertical quadrupolar electromagnet (0.1 Tesla) and a proton resonance frequency of 4.5 MHz. Our main imaging methods are the inversion-recovery or IR, saturation-recovery, or SR, and calculated T/sub 1/. Difference, or D images, constructed by subtracting the data of the IR signal from that of the SR signal, have also been obtained in some cases. The system allows averaging of raw data. Hybrid images were constructed from two or more images to obtain clear definition of areas of interest. By using the hybrid image, several tissues of different relaxation times can be shown in the same image. Application in our study of the newly developed hybrid image indicates its importance in the detection and diagnosis of lesion, especially the detection of the differentiation of an edematous lesion from a tumor, and also abnormal fluid collection such as the pleural effusion or ascites. We hope that ...
1985-01-01
The vertical profiles of disc galaxies are built by the material trapped around stable periodic orbits, which form their "skeletons". According to this, the knowledge of the stability of the main families of periodic orbits in appropriate 3D models, can predict possible morphologies for edge-on disc galaxies. In a pilot survey we compare the orbital structures which lead to the appearance of "peanuts" and "X"-like features with the edge-on profiles of three disc galaxies (IC 2531, NGC 4013 and UGC 2048). The subtraction from the images of a model representing the axisymmetric component of the galaxies reveals the contribution of the non-axisymmetric terms. We find a direct correspondence between the orbital profiles of 3D bars in models and the observed main morphological features of the residuals. We also apply a simple unsharp masking technique in order to study the sharpest features of the images. Our basic conclusion is that the morphology of the boxy "bulges" ...
2006-01-01
Asymptotic numbers and wave packets
International Nuclear Information System (INIS)
An attempt is made to generalize the spaces of numbers and functions in order to consider certain problems in quantum mechanics, especially in the cases, where wave functions appear which do not belong to the Hilbert space L"2. Often the Soboljev - Schwartz distributions are used but they are not always the appropriate tool because they cannot be multiplied. A modification of the definition of generalized functions PSI(x vector) is proposed by particular conditions. Such conditions imposed on the wave function of a free particle seems to be the most natural by means of physics. It appears, however, that for all spaces with a real norm these conditions are contradictory. This implies together with the extension of the space of functions, an extension of the space of numbers with so called asymptotic numbers A. The four algebraic operations - addition, subtraction, multiplication and division are defined in the set A. To avoid the contradictions between the ...
1976-01-26
Energy Technology Data Exchange (ETDEWEB)
The previous judgment of eutrophic state, once proposed for the Trasimeno Lake (Umbria region, Italy), has been revised. According to Vollenweider-OECD classification criterion, the lake waters are at present to be classified as mesotrophic waters, with phosphorus limitation. However this level of moderate productivity results to be conditioned by the hydrochemical characteristics of the lake waters, that control phosphorus concentrations independently from the loading coming from the basin, and prevent dangerous and massive algal blooms. Different processes of chemical nature, regulating the phosphorus amount in the lake waters, are then reviewed: adsorption of P/P0(4) onto suspended materials, particularly clay mineral particles, and direct precipitation as hydroxylapatite or co-precipitation with carbonates, are found to be the principal mechanisms that determine chemical removal of phosphorus from the water column. A preliminary mass balance of phosphorus ...
1995-06-01
With iWork '09: The Missing Manual, you'll quickly learn everything you need to know about Apple's incredible productivity programs, including the Pages word-processor, the Numbers spreadsheet, and the Keynote presentation program that Al Gore and Steve Jobs made famous. This book gives you crystal-clear and jargon-free explanations of iWork's capabilities, advantages, and limitations to help you produce stunning documents and cinema-quality digital presentations in no time.
2009-01-01
Three-Dimensional Dispaly Of Document Set
Energy Technology Data Exchange (ETDEWEB)
A method for spatializing text content for enhanced visual browsing and analysis. The invention is applied to large text document corpora such as digital libraries, regulations and procedures, archived reports, and the like. The text content from these sources may be transformed to a spatial representation that preserves informational characteristics from the documents. The three-dimensional representation may then be visually browsed and analyzed in ways that avoid language processing and that reduce the analysts' effort.
2003-06-24
Study for the Optimal Operation of D(sub 2)O Vapour Recovery System.
Digital control technology using micro-processor is widely used in Factory Automation area since 1980's. However, the D(sub 2)O Vapour Recovery System in Wolsung 1 N.P.P is controlled by mechanical timer without considering the moisture condition in the R...
1997-01-01
Solar Eclipse Images - SDAC Home Page - NASA
Oct 24, 1995 ... The photos were made with a Nikon FE and a Sigma 400mm APO f/5.6 lens ... Note: The JPEG images to which the above links point contain subtle ... India on 1995 October 24 with a digital camera and Fe X 6374 ? filter, ...
Scalable digital libraries of event data and the NSCP meta-cluster
Energy Technology Data Exchange (ETDEWEB)
In this paper we present the design, implementation, and experimental results of a system to mine and visualize event data using cluster computingbuilt upon an ATM network. Our approach is to build a system using light weight, modular software tools for data management, resource management, data analysis and visualization developed for local, campus and wide area clusters of workstations. (author)
1996-07-01
UK PubMed Central (United Kingdom)
The actual mechanisms that maintain the individual disparities in home computer use and internet access that are collectively termed “the digital divide” remain unclear. We hypothesized...Full Text Available
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
The topics covered at the conference include: mineral exploration; geological mapping/stratigraphy; environmental monitoring and hydrology; petroleum exploration; radar digital elevation mapping; new commercial remote sensing initiatives; geological hazards and engineering; processing and integration techniques; and hyperspectral geology.
1997-12-31
Optimal Knot Selection for Least-squares Fitting of Noisy Data with Spline Functions
Energy Technology Data Exchange (ETDEWEB)
An automatic data-smoothing algorithm for data from digital oscilloscopes is described. The algorithm adjusts the bandwidth of the filtering as a function of time to provide minimum mean squared error at each time. It produces an estimate of the root-mean-square error as a function of time and does so without any statistical assumptions about the unknown signal. The algorithm is based on least-squares fitting to the data of cubic spline functions.
2008-05-15
Microsoft Word - postpn270.doc
protect digital information, from personal details held on a computer to financial details transmitted over the Internet. Encryption ...in connection with electronic data (Box 2), whether stored on a computer or transmitted over an unsecured network such as ...Encryption tools (usually in the form of computer programs or software) are widely available
Measurements of nuclear emulsion tracks by means of a picture analysis system
Energy Technology Data Exchange (ETDEWEB)
A semiautomatic system for measurements of nuclear tracks in nuclear emulsion is described. The microscopic image of a particle track is picked up by a video camera. The video picture is digitized in real time. The picture analysis is done via software. The microscope is equipped with a stepping motor driven stage which is also computer-controlled.
1986-01-01
Lagrangian analysis of contaminant dispersal in bounded turbulent shear flows
Energy Technology Data Exchange (ETDEWEB)
Methods of solving Navier-Stokes equations for turbulent channel flow are given. These numerical solutions utilize either Neumann or Dirichlet boundary conditions. Computer codes were written and tested and are discussed. Digital image processing of flow visualization video sequences, taken simultaneously with vorticity probe measurements in a turbulent boundary layer, were carried out. 4 figs. (GHH)
1991-01-01
Energy Technology Data Exchange (ETDEWEB)
This paper describes the implementations of a fuzzy logic based self-tuned controller to improve the stability of electric power systems. The stabilizing signal is computed using the standard fuzzy membership function depending on the speed/acceleration state of the generator in the phase plane. The performance of the proposed stabilizer is demonstrated by practical implementation using a digital signal processor mounted on a PC-AT. Results of the experimental tests on a physical model of a power system are presented.
1993-06-01
Image-enhancement applications at the Lawrence Livermore National Laboratory
Energy Technology Data Exchange (ETDEWEB)
A diverse set of digital image-processing applications exists at the Lawrence Livermore National Laboratory. While many of these include some sort of image analysis or restoration, virtually all of them require image-enhancement procedures. In this paper we describe the principal image-processing facility at the Laboratory, followed by a discussion of several of the major image-processing application areas.
1982-06-01
Energy Technology Data Exchange (ETDEWEB)
This paper introduces a multichannel digital data acquisition system and examples of measurements with the system in seismic exploration using the high resolution seismic refraction method. The high resolution seismic refraction system performs analyses nearly automatically by using a computer after initial travel time has been read. Therefore, the system requires high-accuracy travel time data, for which a multichannel digital measuring instrument developed recently for seismic exploration using the refraction method has been used for the measurement. The specification specifies the number of channels at 144 as a maximum, a sampling time of 62.5 {mu}sec to 4 m sec, the maximum number of sampling of 80,000 samples, and gain accuracy of {plus_minus} 1%. The system was used for surveying a tunnel having a maximum soil cover of about 800 m. The traverse line length is about 6 km, the distance between vibration receiving points is 50 m, and the ...
1997-05-27
Energy Technology Data Exchange (ETDEWEB)
In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).
1993-12-01
Evaluation of the 1Shot Phantom dedicated to the mammography system using FCR
International Nuclear Information System (INIS)
Currently daily quality control (QC) tests for mammography systems are generally evaluated by using visual analysis phantoms, which of course means subjective measurement. In our study, however, we evaluated a novel digital phantom, the 1Shot Phantom M plus (1Shot Phantom), together with automatic analysis software dedicated for mammography systems using Fuji computed radiography (FCR). The digital phantom enables objective evaluation by providing for actual physical measurement rather than subjective visual assessment. We measured contrast to noise ratio (CNR), image receptor homogeneity, missed tissue at chest wall side, modulation transfer function (MTF), and geometric distortion utilizing the 1Shot Phantom. We then compared the values obtained using the 1Shot Phantom with values obtained from the European guidelines and International Electrotechnical Commission (IEC) standards. In addition, we evaluated the convenience of using the ...
2009-07-01
Estimation of errors provided with dead times of roentgen digital tomography
International Nuclear Information System (INIS)
Impact of apparatus dead time on the accuracy of measurement of radial distribution of the radiation attenuation factor in the roentgen computer tomography for rotation bodies is studied. Analytical expressions are obtained. Calculations of the threshold loads for radiometric detectors, providing for the accuracy of measurement at the stage of designing the tomographic complex detecting unit, are obtained
Energy Technology Data Exchange (ETDEWEB)
An electrical circuit testing device is provided, comprising a case, a digital voltage level testing circuit with a display means, a switch to initiate measurement using the device, a non-shorting switching means for selecting pre-determined electrical wiring configurations to be tested in an outlet, a terminal block, a five-pole electrical plug mounted on the case surface and a set of adapters that can be used for various multiple-pronged electrical outlet configurations for voltages from 100 600 VAC from 50 100 Hz.
2006-04-18
Digital atlas of fetal brain MRI
International Nuclear Information System (INIS)
Fetal MRI can be performed in the second and third trimesters. During this time, the fetal brain undergoes profound structural changes. Interpretation of appropriate development might require comparison with normal age-based models. Consultation of a hard-copy atlas is limited by the inability to compare multiple ages simultaneously. To provide images of normal fetal brains from weeks 18 through 37 in a digital format that can be reviewed interactively. This will facilitate recognition of abnormal brain development. T2-W images for the atlas were obtained from fetal MR studies of normal brains scanned for other indications from 2005 to 2007. Images were oriented in standard axial, coronal and sagittal projections, with laterality established by situs. Gestational age was determined by last menstrual period, earliest US measurements and sonogram performed on the same day as the MR. The software program used for viewing the atlas, written in C, permits linked ...
2010-02-01
Development of Hardware for Power System Stabilizer (PSS)
Energy Technology Data Exchange (ETDEWEB)
The basic function of a Power System Stabilizer (PSS) is to add damping to the generator rotor oscillations by controlling its excitation using auxiliary stabilizing signals. To provide damping, the stabilizer must produce a component of electrical torque in phase with the rotor speed deviations. This paper introduces the hardware specifications and various functions of microprocessor (TMS320C32)-based digital PSS to provide the damping torque. (author). 3 refs., 6 figs.
2001-07-01
Creating Open Digital Library Using XML Implementation of OAi-PMH Protocol at CERN
This article describes the implementation of the OAi-PMH protocol within the CERN Document Server (CDS). In terms of the protocol, CERN acts both as a data provider and service provider and the two core applications are described. The application of XML Schema and XSLT technology is emphasized.
2002-01-01
Convergenomics Strategic Innovation in the Convergence Era
Convergenomics is about the megatrends that are shaping how people behave and organizations work. In this insightful analysis, Sang Lee and David Olson describe how globalization, digitization, changing demographics, changing industry mix, deregulation and privatization, commoditization of processes, new value chains, emerging new economies, deteriorating environment, and cultural conflicts have led to what they define as a convergence revolution.Lee and Olson discuss this convergence revolution from the perspectives of technology, industry, knowledge, open-source networking and bio-artificial
2010-01-01
International Nuclear Information System (INIS)
We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curve, modulation transfer function (MTF), Wiener spectrum (WS), noise equivalent quanta (NEQ)) for Cannon's flat-panel detector (FPD), Fuji computed radiography (FCR) and screen-film (S/F) systems, respectively. First, the digital and overall characteristic curves of FPD and FCR systems were more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of FPD system were better than those of FCR system a little at lower spatial frequencies than 0.8 mm"-"1, but the overall MTF of FPD and FCR systems were worse than that of S/F system a little at all spatial frequencies. Third, the digital and overall WS of FPD system were similar or better than those of FCR system, but the overall WS of FPD and FCR systems were worse than that of S/F system. Fourth, the pre-sampling and overall NEQ of FPD system ...
2002-12-01
Energy Technology Data Exchange (ETDEWEB)
We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curve, modulation transfer function (MTF), Wiener spectrum (WS), noise equivalent quanta (NEQ)) for Cannon's flat-panel detector (FPD), Fuji computed radiography (FCR) and screen-film (S/F) systems, respectively. First, the digital and overall characteristic curves of FPD and FCR systems were more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of FPD system were better than those of FCR system a little at lower spatial frequencies than 0.8 mm{sup -1}, but the overall MTF of FPD and FCR systems were worse than that of S/F system a little at all spatial frequencies. Third, the digital and overall WS of FPD system were similar or better than those of FCR system, but the overall WS of FPD and FCR systems were worse than that of S/F system. Fourth, the pre-sampling and overall NEQ of ...
2002-12-01
Energy Technology Data Exchange (ETDEWEB)
The coal mining district in southeastern Santa Catarina State is considered one of the most polluted areas of Brazil. The author has identified significant preliminary results on the application of MSS-LANDSAT digital data to monitor the coal refuse areas and its environmental consequences in this region.
1982-05-01
Application of neural networks to pulse-shape analysis of Bragg curves
Energy Technology Data Exchange (ETDEWEB)
A novel approach is presented to extract relevant parameters associated with the energy loss of ejectiles from nuclear reactions obtained by digitizing the signals of a Bragg curve spectrometer. New and more powerful computational paradigms allow a more thorough pulse-shape analysis. This is fulfilled using a back-propagation artificial neural network as a pattern identifier. The known problem of over-training is discussed.
2006-01-15
Advantages of magnification in digital phase-contrast mammography using a practical X-ray tube
Energy Technology Data Exchange (ETDEWEB)
Phase-contrast imaging with a practical cone-beam X-ray tube has been realized for clinical use in digital mammography using computed radiography (CR). To perform phase-contrast imaging, the X-ray detector must be distanced from an object so that the phase-contrast image achieves magnification; in a mammography unit dedicated to phase-contrast imaging, the magnification ratio is 1.75. When using an X-ray tube with a 0.1-mm focal spot, it appears that the penumbra in magnification blurs both projected images and the phase contrast, which generates an edge effect. However, where the sampling pitch of the CR plate is 43.75 {mu}m, the blur stretches the width of the phase contrast so that unit pixels in the detector can capture it. Note that the width of an ideal phase contrast using an X-ray point source results in a phase contrast too narrow for detection with CR. In addition to phase contrast improving image quality, a re-scaling effect increases image sharpness in ...
2008-12-15
Accessibility and Metadata in Digital Libraries
Metadata can be used to support accessibility in connection with improved discovery. ...certain metadata elements provide information about what capabilities are needed--either perceptual-motor, cognitive, socio-economic or geographic--to make use of a resource. This cam improve the ability of users who are disadvantaged in these ways to find resources that meet their needs--and avoid ones [resources] that do not.
2003-03-18
Ultra high-speed (508 MHz) beam position digital feedback system
Energy Technology Data Exchange (ETDEWEB)
The B-Factory which is constructed by National Laboratory for High Energy Physics is the device for elucidating the breakdown of symmetry of matter and antimatter by studying the behavior of B mesons which are generated in large quantity when the electrons and the positrons which are accelerated to light velocity level are collided. In order to maintain electron beam-positron beam bunch circling the ring at light velocity stably, the instability of the coupled bunch must be overcome. For this purpose, the ultrahigh speed beam position digital feedback control system was developed. This system is composed of the high speed input-output substrate using GaAs LSI, the feedback computation substrate using complementary metal oxide semiconductor and the memory mounted on it, and the real time operation device. The development of both substrates and their functions are explained. The real time data collection and the change of computation parameters for specific bunch in ...
1997-02-01
Three-Dimensional Wing Kinematics and Aerodynamic Characteristics of a Beetle in Free Flight
Detailed three dimensional wing kinematics and aerodynamic characteristics are experimentally presented for the free flight of a beetle, Allomyrina dichotoma, which has a pair of elytra (fore wings) and hind wings. The kinematic parameters of the wing motion, such as the wing tip trajectory, angle of attack, torsion angle, and camber deformation, are obtained from a 3D reconstruction technique that involves the use of two or three synchronized high-speed cameras to digitize various points marked on the wings. Our data show outstanding characteristics of wing deformation and flexibility in the free flight of the beetle. To find out the mechanism of aerodynamic force, the leading edge vortex (LEV) and trailing edge vortex (TEV) on both elytron and hind wing were observed by using smoke wire visualization and digital particle image velocimetry (DPIV) technique. Qualitative smoke lines in the region of the most intent vortex shedding demonstrate ...
2010-11-01
The Sloan Digital Sky Survey DR7 Spectroscopic M Dwarf Catalog I: Data
We present a spectroscopic catalog of 70,841 visually inspected M dwarfs from the seventh data release of the Sloan Digital Sky Survey (SDSS). For each spectrum, we provide measurements of the spectral type, a number of molecular bandheads, and the H-alpha, H-beta, H-gamma, H-delta and Ca II K emission lines. In addition, we calculate the metallicity-sensitive parameter zeta and identify a relationship between zeta and the g-r and r-z colors of M dwarfs. We assess the precision of our spectral types (which were assigned by individual examination), review the bulk attributes of the sample, and examine the magnetic activity properties of M dwarfs, in particular those traced by the higher order Balmer transitions. Our catalog is cross-matched to Two Micron All Sky Survey (2MASS) infrared data, and contains photometric distances for each star. Lastly, we identify eight new late-type M dwarfs that are possibly within 25 pc of the Sun. Future studies will use these data ...
2011-01-01
Surface brightness and effective radius for elliptical galaxies
International Nuclear Information System (INIS)
Seeing convolved two-dimensional de Vaucouleurs profiles have been fitted to digital images of the brightest elliptical galaxies in two nearby groups of galaxies and three clusters of galaxies with redshifts in the range 0.06 to 0.15. The digital images were created by scanning electronographic plates obtained by the use of several versions of the RGO electronographic camera. The linear relation between effective surface brightness #mu#/sub e/ and the logarithm of the effective radius r/sub e/, first discovered by Kormendy to be valid for nearby elliptical galaxies, is found to be equally valid for the largest and brightest galaxies in rich clusters of galaxies. The apparent universal nature of that relation indicates that the same type of processes might have been involved during the formation of all ellipticals from cD galaxies in clusters to fainter ellipticals in small groups. It is suggested that the (I/sub e/,r/sub e/) relation is not ...
International Nuclear Information System (INIS)
The nuclide "2"4"1Am decays by alpha emission to "2"3"7Np. Most of the decays (84.6%) populate the excited level of "2"3"7Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of "2"4"1Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.
2009-09-07
Skip-webs: Efficient distributed data structures for multi-dimensional data sets
DEFF Research Database (Denmark)
We present a framework for designing efficient distributed data structures for multi-dimensional data. Our structures, which we call skip-webs, extend and improve previous randomized distributed data structures, including skipnets and skip graphs. Our framework applies to a general class of data querying scenarios, which include linear (one-dimensional) data, such as sorted sets, as well as multi-dimensional data, such as d-dimensional octrees and digital tries of character strings defined over a fixed alphabet. We show how to perform a query over such a set of n items spread among n hosts using O(log n / log log n) messages for one-dimensional data, or O(log n) messages for fixed-dimensional data, while using only O(log n) space per host. We also show how to make such structures dynamic so as to allow for insertions and deletions in O(log n) messages for quadtrees, octrees, and digital tries, and O(log n / log log n) messages for ...
2005-01-01
Ranking Scientific Publications Based on Their Citation Graph
CDS Invenio is the web-based integrated digital library system developed at CERN. It is a suite of applications which provides the framework and tools for building and managing an autonomous digital library server. Within this framework, the goal of this project is to implement new ranking methods based on the bibliographic citation graph extracted from the CDS Invenio database. As a first step, we implemented the Citation Count as a baseline ranking method. The major disadvantage of this method is that all citations are treated equally, disregarding their importance and their publication date. To overcome this drawback, we consider two different approaches: a link-based approach which extends the PageRank model to the bibliographic citation graph and a time-dependent approach which takes into account time in the citation counts. In addition, we also combined these two approaches in a hybrid model based on a time-dependent PageRank. In the ...
2009-01-01
We discuss the estimation of galaxy correlation properties in several volume limited samples, in different sky regions, obtained from the Fourth Data Release of the Sloan Digital Sky Survey. The small scale properties are characterized through the determination of the nearest neighbor probability distribution. By using a very conservative statistical analysis, in the range of scales [0.5,~30] Mpc/h we detect power-law correlations in the conditional density in redshift space, with an exponent \\gamma=1.0 \\pm 0.1. This behavior is stable in all different samples we considered thus it does not depend on galaxy luminosity. In the range of scales [~30,~100] Mpc/h we find evidences for systematic unaveraged fluctuations and we discuss in detail the problems induced by finite volume effects on the determination of the conditional density. We conclude that in such range of scales there is an evidence for a smaller power-law index of the conditional density. However we ...
2006-01-01
PROPERTIES OF DISKS AND BULGES OF SPIRAL AND LENTICULAR GALAXIES IN THE SLOAN DIGITAL SKY SURVEY
International Nuclear Information System (INIS)
A bulge-disk decomposition is made for 737 spiral and lenticular galaxies drawn from a Sloan Digital Sky Survey galaxy sample for which morphological types are estimated. We carry out the bulge-disk decomposition using the growth curve fitting method. It is found that bulge properties, effective radius, effective surface brightness, and also absolute magnitude, change systematically with the morphological sequence; from early to late types, the size becomes somewhat larger, and surface brightness and luminosity fainter. In contrast, disks are nearly universal, their properties remaining similar among disk galaxies irrespective of detailed morphologies from S0 to Sc. While these tendencies were often discussed in previous studies, the present study confirms them based on a large homogeneous magnitude-limited field galaxy sample with morphological types estimated. The systematic change of bulge-to-total luminosity ratio, B/T, along the morphological sequence is ...
2009-11-01
On-line video image processing system for real-time neutron radiography
Energy Technology Data Exchange (ETDEWEB)
The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of gray scale and resolved to 240 x 256 picture elements (pixels) on a monochrome CRT, with the capability also to display 16 ...
1983-09-15
Fuji computed radiography (FCR) for the diagnosis of spinal disorders
International Nuclear Information System (INIS)
Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the cervicothoracic region, where it is usually difficult to obtain clear cervicothoracic films in conventional radiography. We can obtain much precise ...
1987-01-01
Frame Selected Approach for Hiding Data within MPEG Video Using Bit Plane Complexity Segmentation
Bit Plane Complexity Segmentation (BPCS) digital picture steganography is a technique to hide data inside an image file. BPCS achieves high embedding rates with low distortion based on the theory that noise-like regions in an image's bit-planes can be replaced with noise-like secret data without significant loss in image quality. . In this framework we will propose a collaborate approach for select frame for Hiding Data within MPEG Video Using Bit Plane Complexity Segmentation. This approach will invent high secure data hidden using select frame form MPEG Video and furthermore we will assign the well-built of the approach; during this review the author will answer the question why they used select frame steganography. In additional to the security issues we will use the digital video as a cover to the data hidden. The reason behind opt the video cover in this approach is the huge amount of single frames image per sec which in turn overcome the ...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
A computer-aided detection (CAD) system was evaluated for its ability to detect microcalcifications and masses on images obtained with a digital phase-contrast mammography (PCM) system, a system characterised by the sharp images provided by phase contrast and by the high resolution of 25-{mu}m-pixel mammograms. Fifty abnormal and 50 normal mammograms were collected from about 3,500 mammograms and printed on film for reading on a light box. Seven qualified radiologists participated in an observer study based on receiver operating characteristic (ROC) analysis. The average of the areas under ROC curve (AUC) values for the ROC analysis with and without CAD were 0.927 and 0.897 respectively (P = 0.015). The AUC values improved from 0.840 to 0.888 for microcalcifications (P = 0.034) and from 0.947 to 0.962 for masses (P = 0.025) respectively. The application of CAD to the PCM system is a promising approach for the detection of breast cancer in its early stages. (orig.)
2009-12-15
We show how to obtain a fast component-by-component construction algorithm for higher order polynomial lattice rules. Such rules are useful for multivariate quadrature of high-dimensional smooth functions over the unit cube as they achieve the near optimal order of convergence. The main problem addressed in this paper is to find an efficient way of computing the worst-case error. A general algorithm is presented and explicit expressions for base~2 are given. To obtain an efficient component-by-component construction algorithm we exploit the structure of the underlying cyclic group. We compare our new higher order multivariate quadrature rules to existing quadrature rules based on higher order digital nets by computing their worst-case error. These numerical results show that the higher order polynomial lattice rules improve upon the known constructions of quasi-Monte Carlo rules based on higher order digital nets.
2011-01-01
Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures
Energy Technology Data Exchange (ETDEWEB)
AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the performance of caesium iodide/amorphous silicon ...
2002-04-01
Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures
International Nuclear Information System (INIS)
AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the performance of caesium iodide/amorphous silicon ...
2002-04-01
Digital luminescent radiography: A substitute for conventional chest radiography?
International Nuclear Information System (INIS)
The image quality of digital luminescent radiography (DLR) is sufficient for routine biplane chest radiography and for follow-up studies of heart size, pulmonary congestion, coin lesions, infiltrations, atelectasis, pleural effusions, and mediastinal and hilar lymph node enlargement. Chest radiography in the intensive care unit may in most cases be performed using the DLR technique. there is no need for repeat shots because of incorrect exposure, and the position of catheters, tubes, pacemakers, drains and artificial heart valves, the mediastinum, and the retrocardiac areas of the left lung are more confidently assessed on the edge-enhanced DLR films than on conventional films. Nevertheless, DLR is somewhat inferior to conventional film-screen radiography of the chest as it can demonstrate or rule out subtle pulmonary interstitial disease less confidently. There is no reduction of radiation exposure of the chest in DLR compared with modern film-screen systems. As a ...
Energy Technology Data Exchange (ETDEWEB)
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the reconstructed image. The image quality could be satisfactory to distinguish acrylic ...
1984-09-01
International Nuclear Information System (INIS)
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the reconstructed image. The image quality could be satisfactory to distinguish acrylic ...
1984-01-01
Determination of Inter-Phase Line Tension in Langmuir Films
A Langmuir film is a molecularly thin film on the surface of a fluid; we study the evolution of a Langmuir film with two co-existing fluid phases driven by an inter-phase line tension and damped by the viscous drag of the underlying subfluid. Experimentally, we study an 8CB Langmuir film via digitally-imaged Brewster Angle Microscopy (BAM) in a four-roll mill setup which applies a transient strain and images the response. When a compact domain is stretched by the imposed strain, it first assumes a bola shape with two tear-drop shaped reservoirs connected by a thin tether which then slowly relaxes to a circular domain which minimizes the interfacial energy of the system. We process the digital images of the experiment to extract the domain shapes. We then use one of these shapes as an initial condition for the numerical solution of a boundary-integral model of the underlying hydrodynamics and compare the subsequent images of the experiment to ...
2007-01-01
Design improvements and operational experience of programmable digital comparator system
International Nuclear Information System (INIS)
Application of Programmable Digital Comparator System (PDCS) in NPP is to monitor large number of plant parameters and generate contact outputs for reactor trip, reactor setback, process interlocks etc. when parameters cross their operational bounds. Till NAPS these functions are achieved through individual Indicating Alarm Meters (IAM). PDCS used for the first time in KAPS replaces these IAMs. Since its inception, PDCS has undergone improvements in design, incorporates additional functionalities/enhanced features. Dedicated PDCS is provided in TAPP-3 and 4 for protection function. System re-configurability, on-line inter channel comparison of safety critical process parameters' values, Graphic User Interface etc. are other enhancements. From KAPS to TAPP-4 system has given many years of almost trouble-free operation. Commissioning of TAPP-3 system has been very smooth. Objective of the paper is to describe the advantage of the new system, its operating experience, ...
2006-11-13
International Nuclear Information System (INIS)
Mammography has emerged as a reliable non-invasive technique for the early detection of breast cancer--the second leading cause of cancer-related mortality among American women. The radiographic appearance of the female breast consists of radiolucent (dark) regions due to fat and radiodense (light) regions due to connective and epithelial tissue. The amount of radiodense tissue can be used as a marker for predicting breast cancer risk. This paper presents the development of an algorithm for estimating the percentage of radiodense tissue in a digitized mammogram. The technique involves determining a dynamic threshold for segmenting radiodense indications in mammograms. Both the mammographic image and the threshold are modeled as Gaussian random variables. This work is intended to support a concurrent study at the Fox Chase Cancer Center (FCCC) exploring the association between dietary patterns and breast cancer risk. Mammograms have been obtained from an existing ...
2002-05-25
Assessment of the effects of pixel loss on image quality in direct digital radiography
Energy Technology Data Exchange (ETDEWEB)
Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. Measurement of the MTF, NPS and DQE can ...
2004-03-21
Assessment of the effects of pixel loss on image quality in direct digital radiography
International Nuclear Information System (INIS)
Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. Measurement of the MTF, NPS and DQE can reveal small changes in image quality ...
2004-03-21
We analyze archived Chandra and XMM-Newton X-ray observations of 536 Sloan Digital Sky Survey (SDSS) Data Release 5 (DR5) quasars (QSOs) at 1.7 <= z <= 2.7 in order to characterize the relative UV and X-ray spectral properties of QSOs that do not have broad UV absorption lines (BALs). We constrain the fraction of X-ray weak, non-BAL QSOs and find that such objects are rare; for example, sources underluminous by a factor of 10 comprise $\\la$2% of optically-selected SDSS QSOs. X-ray luminosities vary with respect to UV emission by a factor of $\\la$2 over several years for most sources. UV continuum reddening and the presence of narrow-line absorbing systems are not strongly associated with X-ray weakness in our sample. X-ray brightness is significantly correlated with UV emission line properties, so that relatively X-ray weak, non-BAL QSOs generally have weaker, blueshifted CIV$\\lambda$1549 emission and broader CIII]$\\lambda$1909 lines. The CIV emission ...
2008-01-01
Applications of a downhole programmable microprocessor for a geothermal borehole inspection tool
Energy Technology Data Exchange (ETDEWEB)
The high-temperature scanning borehole inspection system is currently being developed jointly by the Los Alamos National Laboratory (LANL) and Westfalische Berggewerkschaftskasse (WBK) of West Germany. The downhole instrument is a digital televiewer that utilized a microprocessor to digitize, process and transmit the acoustic information to the surface acquisition and control system. The primary operation of the downhole acoustic assembly uses a piezoelectric crystal acting as a receiver-transmitter which is mounted on the rotating head. The crystal emits a burst of acoustic energy that propagates through the borehole fluid with a portion of the energy reflected by the borehole wall back to the crystal. The time of travel and the amplitude of the reflected signal are conditioned by the microprocessor and transmitted along with other pertinent data to the surface data processing center. This instrument has been designed specifically for use in ...
1987-01-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this paper is to present an analysis of lightning fault detection, location and protection using numeric distance relays applied in high voltage transmission lines, more specifically in the 500 kV transmission lines of CEMIG (Brazilian Energy Utility) between the Vespasiano 2 - Neves 1 (short line - 23.9 km) and Vespasiano 2 - Mesquita (long line - 148.6 km) substations. The analysis was based on the simulations results of numeric distance protective relays on power transmission lines, realized in September 02 to 06, 2002, at Siemens AG's facilities (Erlangen - Germany), using Real Time Digital Simulator (RTDS{sup TM}). Several lightning faults simulations were accomplished, in several conditions of the electrical power system where the protective relays would be installed. The results are presented not only with the times of lightning faults elimination, but also all the functionality of a protection system, including the correct detection, ...
2007-07-01
Energy Technology Data Exchange (ETDEWEB)
The object of this research is the evaluation of the performance of ultra high speed relays (UHSR's) used for protection of a-c transmission lines. For purposes of this report, these are relays whose response time is less than a quarter of a cycle of the 60 Hz wave (i.e. 4.167 ms.). To identify relaying schemes that may comply with this definition, a literature survey was undertaken. The selected relays were studied in detail and modeled on a digital computer. A theoretical description of these relays is presented. Records of real transient data as well as of simulated data were used as input to the digital models of relays. The real data were recorded by means of monitoring stations connected to the Florida Power and Light Company transmission lines. The simulated data were obtained by modeling the relevant parts of the utility's transmission system using a University of British Columbia simplified version of the well known ...
1984-01-01
An on-line video image processing system for real-time neutron radiography
International Nuclear Information System (INIS)
The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of gray scale and resolved to 240 x 256 picture elements (pixels) on a monochrome CRT, with the capability also to display 16 ...
1983-09-01
An adaptive self-optimizing power system stabilizer
Energy Technology Data Exchange (ETDEWEB)
A self-optimizing pole-shifting control algorithm has been developed for an adaptive power system stabilizer (APSS) to improve its dynamic performance and autonomous operation. The proposed algorithm deals with the system frequency and time domain characteristics simultaneously to guarantee stability and to enhance the performance of the closed-loop system. The mechanism of discrete control system control limits influencing the closed loop system behaviour is studied. Short-term behaviour is studied by introducing the concept of a short-term behaviour index. With the introduction of dynamic control limits, an effective discrete control system design method is proposed. A PSS oriented power system dynamics simulation package (PSDSP) has been developed. Using the PSDSP, simulation studies were performed with the proposed APSS applied to a single machine and a multi machine power system. The performance of the APSS is satisfactory and is discussed. An Intel iSBC386/21 processor was ...
1994-01-01
International Nuclear Information System (INIS)
Due to the failure of the instrument and control devices of nuclear power plants caused by aging, nuclear power plants occasionally trip. Even a trip of a single nuclear power plant (NPP) causes an extravagant economical loss and deteriorates public acceptance of nuclear power plants. Therefore, the replacement of the instrument and control devices with proper consideration of the aging effect is necessary in order to prevent the inadvertent trip. In this paper we investigated the optimal replacement periods of the control computer's components of Wolsung nuclear power plant Unit 1. We first derived mathematical models of optimal replacement periods to the digital control computer's components of Wolsung NPP Unit 1 and calculated the optimal replacement periods analytically. We compared the periods with the replacement periods currently used at Wolsung NPP Unit 1. The periods used at Wolsung is not based on mathematical analysis, but on empirical knowledge. As a ...
1993-01-01
Three-frame Algorithm of Car Path Reconstruction from Airborne Traffic Data
The airborne traffic monitoring system forms a novel technology of detecting vehicle motion. An optical digital camera located on an airborne platform produces a series of images which then are processed to recognized the fixed vehicles. In this way the video data are converted into the time sequence of frames containing the vehicle coordinates. In the present work a three-frame algorithm is developed to identify the succeeding vehicle positions. It is based on finding the neighboring points in the frame sequence characterized by minimal acceleration. To verify and optimize the developed algorithm a ``Virtual Road'' simulator was created. Finally available empirical data are analyzed using the created algorithm.
2007-01-01
The full scope simulator hardware I/O realization in Daya bay nuclear power station
International Nuclear Information System (INIS)
The full scope simulator in Daya Bay Nuclear Power Station is imported from THOMSON-CSF company in France. It is a large facility, using digital simulation technology, that simulate the main control room of Daya Bay Nuclear Power Station with the high fidelity. It is used for training operators; system analyzing including operation procedure verification. The input output interface system of the simulator is the bridge of the information exchange between instrumentation and the computer. From the point of view of data transfer, this paper discusses the operation principle of the I/O interface system.
THE DEVIL AND CUSTOMER RELATIONSHIP MANAGEMENT
British Library Electronic Table of Contents (United Kingdom)
The paper takes as its starting point the diffusion of ICT applications associated with so-called 'customer relationship management' (CRM). CRM encourages organisations to shift their understanding of customers from an episodic and transaction-based perspective to one that emphasises continuous 'relationship management'. CRM applications thus promise to deliver more, real-time accurate information about consumer habits and behaviours therefore allowing organisations to maximise their extraction of business value. This paper explores the ways in which such inscriptive technologies are not merely referential but also constitutive of contemporary re-presentations and ideals of the consuming subject. Focusing on what we might call the 'digital doubles' of customer relationship management the a...
2010-01-01
State-of-the-art technique for power system stabilizer tuning
Energy Technology Data Exchange (ETDEWEB)
Power System Stabilizers (PSS) have broad application throughout the world. PSS application requires careful tuning which is usually accomplished in the field with the generator and power system in an abnormal condition. Recently developed equipment which combines fast Fourier transform capability with digital computer technique provides a means of PSS tuning which is faster and more accurate than was previously obtainable. This paper describes a PSS tuning test conducted using the new technique. The advantages will be apparent to the reader. The described test is very poignant as evidenced by two unexpected occurrences of instability.
1983-03-01
Prospective application of advanced series compensation to improve transmission system performance
Energy Technology Data Exchange (ETDEWEB)
This paper describes the main aspects and results of the planning studies undertaken to evaluate the technical benefits of using Thyristor Controlled Series Compensation (TCSC), in a large 500 kV transmission system (Brazilian North-Northeast system). TCSC controllers design and simplified models for digital non-linear time domain simulations are discussed. The proposed controllers are tuned and used to support the comparative analysis between controlled and fixed series compensation. The relevant conclusions concerning this comparison are highlighted. (author) 2 refs., 14 figs., 3 tabs.
1994-12-31
International Nuclear Information System (INIS)
The exchange of information and experience among Member Sates is an essential component of the IAEA action plan for addressing the Year 2000 problem. The objective is to enable Member States to identify any gaps in their own conversion programmes, benefit form the experience of others in developing remedial actions and establish the basis for future action to solve remaining problems. Experts in Year 2000 issues particularly those related to digital equipment prepared this report dealing with nuclear fuel cycle facilities
1993-04-18
Performance measurements of the Pionier-I 15 m VAWT. Prestatiemetingen aan de Pionier-I 15 m VAWT
Energy Technology Data Exchange (ETDEWEB)
Pionier-I is a vertical axis wind turbine (VAWT) of the Darrieus-type with a diameter of 15 m. In the month of September 1983 performance and efficiency were measured. Measurements were done with constant rotational speed and with constant tip speed ratio. For the calculation of the possible (theoretical) output of electric power an anemometer was present. Measurement results are conditioned to one digital signal and processed by a microcomputer (Apple II). It becomes evident that the yearly energy output of the Pionier-I is quite well comparable with that of a horizontal axis turbine with the same diameter.
1983-01-01
This document contains 142 papers on PT3 (Preparing Tomorrow's Teachers to use Technology) from the SITE (Society for Information Technology & Teacher Education) 2002 conference. Topics covered include: a technology in urban education summit; student professional development; meeting NCATE (National Council of Teachers of English) standards; faculty use of WebCT; preparing teachers for the digital age; technology in K-8 multicultural classrooms; using immersive 360 degree images; consortium building; student evaluation; technology fellows; incentives that facilitate institutional change; impact of a temporary grant; a consortium for outstanding achievement in teaching with technology; changes implemented after technology professional development sessions; Web-based modules for teaching mathematics to minority students; student teaching technology sites; preservice teachers design technology-enhanced learning experiences; planning, implementing, evaluating, and ...
2002-03-01
Neutron radiography with the cyclotron, 5
International Nuclear Information System (INIS)
Reliable facility of cyclotron-based real time neutron radiography system has been developed and applied to some industrial components. The equipment for neutron fluoroscopy is based on a sub-compact cyclotron and a LiF/ZnS (Ag) fluorescent screen viewed by a silicon intensifier target TV camera. The real time image is monitored on a CRT, recorded with a standard video recorder and processed by a digital image processor. The effectiveness of our real time neutron radiograph has been demonstrated to be applicable to not only the dynamic observation but also the magnifying and stereoscopic observation of fluoroscopic images. (author).
1987-01-01
Prepared and presented by Professor Raj Jain at Washington University in St. Louis, this series of presentations is designed to introduce computer science students to the fundamentals of network security. Visitors have the option of choosing to download or view the presentations with audio, as individual slides only, or as a single PDF document. Topics here include: security requirements, public key encryption, digital signatures, and confidentiality. This is an excellent site for educators to use in the classroom or as a supplementary resource to introduce students to computer network security. Students may also wish to view or download the presentations to learn the basic concepts of network security.
2008-01-30
Making sense of leak detection
Energy Technology Data Exchange (ETDEWEB)
It is estimated that more than 180.000 kilometres of onshore pipelines will be installed between now and 2012. According to the US Federal Office of Pipeline Safety report (1968-97), the average pipeline suffers one leak per year every 400 miles. This equates to a total of 180 expected leaks per year for a new pipeline alone. Sensornet's continuous real-time Digital Leak Detection monitoring solution has the reach, precision and the speed to provide complete, continuous real-time knowledge (author)
2008-07-01
How to start a utility TQM program
Energy Technology Data Exchange (ETDEWEB)
Huntsville, Alabama Utilities has successfully provided services for over 53 years. However, the quality of service demands from customers are changing every day! Part of this demand is due to updated digital appliances, home and business computers, and automated systems. A quality program was initiated in 1992 as a result of an internal assessment. The Malcolm Baldrige approach was selected which includes seven areas: (1) Leadership; (2) Information and Analysis; (3) Strategic Planning; (4) Human Resource Utilization; (5) Quality Assurance of Products and Services: (6) Quality Results: (7) Customer Satisfaction. Training for and implementation of the Quality program is discussed in detail.
1994-12-31
GPLS VME MODULE: A DIAGNOSTIC AND DISPLAY TOOL FOR NSLS MICRO SYSTEMS.
Energy Technology Data Exchange (ETDEWEB)
The General Purpose Light Source VME module is an integral part of every front-end micro in the NSLS control system. The board incorporates features such as a video character generator, clock signals, time-of-day clock, a VME bus interrupter and general-purpose digital inputs and outputs. This module serves as a valuable diagnostic and real-time display tool for the micro development as well as for the final operational systems. This paper describes the functions provided by the board for the NSLS micro control monitor software.
1999-03-29
FCR (Fuji Computed Radiography) in neurosurgery
Energy Technology Data Exchange (ETDEWEB)
As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness.
1988-08-01
FCR (Fuji Computed Radiography) in neurosurgery
International Nuclear Information System (INIS)
As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness. (author).
1988-01-01
FADC signal reconstruction for the MAGIC telescope
Energy Technology Data Exchange (ETDEWEB)
Until April 2007 the Major Atmospheric Gamma ray Imaging Cherenkov (MAGIC) telescope used a 300 MSamples/s flash analog-to-digital converter (FADC) system to sample the shaped photomultiplier tube (PMT) signals produced by the captured Cherenkov photons of air showers. Different algorithms to reconstruct the signal from the read-out samples (extractors) have been implemented and are described and compared. Criteria based on the obtained charge and time resolution/bias are defined and used to judge the different extractors, by applying them to calibration, cosmic and pedestal signals. The achievable charge and time resolution have been derived as functions of the number of incident photo-electrons.
2008-09-11
Explosives 92. Conference proceedings
Energy Technology Data Exchange (ETDEWEB)
17 papers are presented. Topics covered include: the POG system - a new concept in the use of ANFO; demolition of a motorway bridge; presplit and smooth blasting; VIBReX - a predictive code for assessing the effect of blast design on ground vibration; ground vibrations from blasting; digital seismographs; human response to blasting and the effects on planning conditions; landform construction by restoration blasting; use of small diameter explosives; efficient priming; safety management in the explosives industry; and the law on packaging of explosives. Two papers have been abstracted separately.
1992-01-01
Effect of the size of an artificial neural network used as pattern identifier
Energy Technology Data Exchange (ETDEWEB)
A novel way to extract relevant parameters associated with the outgoing ions from nuclear reactions, obtained by digitizing the signals provided by a Bragg curve spectrometer (BCS) is presented. This allowed the implementation of a more thorough pulse-shape analysis. Due to the complexity of this task, it was required to take advantage of new and more powerful computational paradigms. This was fulfilled using a back-propagation artificial neural network (ANN) as a pattern identifier. Over training of ANNs is a common problem during the training stage. In the performance of the ANN there is a compromise between its size and the size of the training set. Here, this effect will be illustrated in relation to the problem of Bragg Curve (BC) identification. (Author)
2003-07-01
Database management system for instrument data management
Energy Technology Data Exchange (ETDEWEB)
Data from many measuring devices throughout the Savannah River Site (SRS) is transmitted to a central location for processing as a vital component in the SRS emergency preparedness and response program. The data processing is currently accomplished using VAX-based FORTRAN programs with the data stored in Digital's Record Management System (RMS) files which is shared using global COMMON. A program is underway to store and process this data using a Structured Query Language (SQL)-based Database Management System (DBMS). The advantages of replacing the current system with one using an SQL-based DBMS are discussed.
1990-01-01
Connectivity in the Astronomy Digital Library
The Astrophysics Data System (ADS) provides an extensive system of links between the literature and other on-line information. Recently, the journals of the American Astronomical Society (AAS) and a group of NASA data centers have collaborated to provide more links between on-line data obtained by space missions and the on-line journals. Authors can now specify which data sets they have used in their article. This information is used by the participants to provide the links between the literature and the data. The ADS is available at: http://ads.harvard.edu
2006-01-01
Conformal radiation therapy: technical requirements and clinical applications
International Nuclear Information System (INIS)
Conformal radiation therapy represents a considerable and attractive challenge in oncology. Its aim is mainly to improve local control by increasing the dose with an acceptable rate of complications. This work overviews the world literature on this subject. The technical and theoretical requirements are highlighted. These requirements include a precise definition of the target volume by digital imaging (essentially CT scan), but also clear view of the target volume and the organs at risk, a specific collimation of the beam, 3-D dose calculations, optimization procedures, and a rigid immobilization of the patient with verification of his position. Moreover, the clinical applications of conformal radiation therapy are reviewed and discussed. (authors). 80 refs., 1 tab.
1995-01-01
Beam position monitor readout and control in the SLC linac
Energy Technology Data Exchange (ETDEWEB)
A beam position monitoring system has been implemented in the first third of the SLC linac which provides a complete scan of the trajectory on a single beam pulse. The data is collected from the local micro-computers and viewed with an updating display at a console or passed on to application programs. The system must operate with interlaced beams so the scans are also interlaced, providing each user with the ability to select the beam, the update rate, and the attenuation level in the digitizing hardware. In addition each user calibrates the hardware for his beam. A description of the system architecture will be presented. 6 refs., 4 figs.
1985-04-01
BUBL LINK Catalogue of Internet Resources
...O | P | Q | R | S | T | U | V | W | X | Y | Z 230 Christianity: general resources ...com: Christianity: General Anno Domini: Jesus Through the Centuries Bible and Homosexuality Christian Theological Research Fellowship Papers Christianity Links and Resources Directory ...Good Digital Collections Lambert's Web Links MUNDUS New Testament Gateway Omnilist of Christian Starting Points Quartz Hill School of Theology Web Library Theology Online ...com: Christianity: General Offers original articles and features about Christianity in general plus annotated links to selected relevant Internet resources, compiled by ...
A driving system for Moessbauer spectrometer
International Nuclear Information System (INIS)
The driving system of a Moessbauer spectrometer is described. The system comprises a minivibrator, a digital generator of the reference velocity signal, and circuits for controlling the vibrator. The reference velocity signal is stored by the control computer in an intermediate storage. The feedback in the control circuits includes correction for nonlinearity of the driving facility. A Moessbauer spectrometer which is equipped with this driving system exhibits a velocity scale nonlinearity below 0.1%. The resonance line width for sodium nitroprusside is 0.27 #+-# 0.01 mm/s. (author). 6 figs., 8 refs.
A PDA-Based ECG Beat Detector for Home Cardiac Care.
Recent rapid growth in mobile computing technologies enables telemedicine applications to operate on mobile devices. Our focus is on the design of an integrated electrocardiogram (ECG) beat detector on a Personal Digital Assistant (PDA) platform for the health screening process. The ECG beat detector module will be supported by the PDA version of Personal Health Information Management System (PHIMS) and Facilitated Accurate Referral Management System (FARMS) through wireless network infrastructure as a home-based mobile cardiac monitoring solution. PMID:17282192
2005-01-01
A 40 GByte/s read-out system for GEM
Energy Technology Data Exchange (ETDEWEB)
The preliminary design of the read-out system for the GEM (Gammas, Electrons, Muons) detector at the Superconducting Super Collider is presented. The system reads all digitized data from the detector data sources at a Level 1 trigger rate of up to 100 kHz. A total read-out bandwidth of 40 GBytes/s is available. Data are stored in buffers that are accessible for further event filtering by an on-line, processor farm. Data are transported to the farm only as they are needed by the higher-level trigger algorithms, leading to a reduced bandwidth requirement in the Data Acquisition System.
1994-04-01
Energy Technology Data Exchange (ETDEWEB)
Present day mammography has not been able to make use of the advantages of digital luminescence radiography because of the limited spatial resolution. The recent development of electromagnetic focusing X-ray tube with effective focal spot sizes from 0.04 to 0.12 mm allows radiographic direct magnification with less geometric blur. It is now possible to combine direct magnification mammography with digital luminescence radiography. By combining high quality storage phosphor screens with an HQ-workstation a spatial resolution of 8 lp/mm is possible for 1.7-fold magnification. For 4-fold spot magnification views spatial resolution can be theoretically increased to approx. 20 lp/mm. One important advantage of digital radiography is the possibility of image-postprocessing. This article presents two sets of standard parameters and three sets of image dependent parameters for better imaging of specific lesions, such as ...
1997-05-01
Sources of toxicity and exposure information for identifying chemicals of high concern to children
International Nuclear Information System (INIS)
Due to the large number of chemicals in commerce without adequate toxicity characterization data, coupled with an ineffective federal policy for chemical management in the United States, many states are grappling with the challenge to identify toxic chemicals that may pose a risk to human health and the environment. Specific populations (e.g., children, elderly) are particularly sensitive to these toxic chemicals. In 2008, the Children's Safe Product Act (CSPA) was passed in Washington State. The CSPA included specific requirements to identify High Priority Chemicals (HPCs) and Chemicals of High Concern to Children (CHCCs). To implement this legislation, a methodology was developed to identify HPCs from authoritative scientific and regulatory sources on the basis of toxicity criteria. Another set of chemicals of concern was then identified from authoritative sources, based on their potential exposure to children. Exposure potential was evaluated by identifying chemicals detected in ...
2010-11-01
Natural and anthropogenic "1"4C in the UK coastal marine environment
International Nuclear Information System (INIS)
Prior to this study, almost no up-to-date information was available on the 'background' level of "1"4C present in the water and biota of the UK coastal marine environment. The weighted mean "1"4C activity derived from the lowest activities of dissolved inorganic carbon (DIC) and biota for sites which are remote from potential sources is 247#centre dot#6#+-#1#centre dot#0 Bq kg"-"1 carbon. This is proposed as the best estimate of the natural/weapons testing 'background' for 1995 and should be subtracted from the activity derived for any sample to establish the excess due to UK anthropogenic inputs. "1"4C activities in the DIC component of seawater and a range of marine biota are significantly enhanced above the expected 'background' value in the environment around the British Nuclear Fuels plc reprocessing plant at Sellafield, Cumbria, NW England and Amersham International plc, Cardiff, Wales. The enrichments around Sellafield are largely confined to the NE Irish ...
1997-07-01
Measuring q sub 0 using supernovae at z approx 0. 3
Energy Technology Data Exchange (ETDEWEB)
The measurement of q{sub o} is extremely important for understanding the quantity of matter in our universe. The measurement of q{sub o} using supernovae of type Ia as standard candles is appealing because it requires less modeling than other methods using galaxies. The challenge with using supernovae to measure q{sub o} is in finding enough of them. In order to find supernovas, we have constructed a very popular f/1 camera for the 3.9m Anglo-Australian Telescope. The camera uses reducing optics that put a 17 in. {times} 17 in. field on a 1024 {times} 1024 pixel Thomson CCD. Using this system, we image to 23rd magnitude in five minutes. We have developed a software package that uses image subtraction to find supernovae that are approximately magnitude 22.4 or brighter in these images. One field can be processed every 6.6 minutes on a relatively unloaded VAX 6000-6510. We estimate that this system should find one supernova in every 105--139 images (about two nights ...
1992-07-01
Energy Technology Data Exchange (ETDEWEB)
The effect that different chemical and physical atomic environments can have on the relative intensities of radiative electron transitions from the filling of K shell vacancies was investigated. The method used involved the detection of photoionization induced X-ray fluorescence. An experimental system based on a hyper pure germanium detector (HPGE) was used to measure the relative K-L and K-M X-ray yields from the photofluorescence of a series of lanthanide elements and compounds. A background subtraction and peak integration strategy was employed which accounted for scattering in the samples and scattering of the flux from the radioisotope photoionization sources. Analysis of the data resulted in a tabulation of relative K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ratios. The measured relative K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ratios were compared to the calculated values predicted by the theoretical development of Scofield and the ...
1987-01-01
International Nuclear Information System (INIS)
The effect that different chemical and physical atomic environments can have on the relative intensities of radiative electron transitions from the filling of K shell vacancies was investigated. The method used involved the detection of photoionization induced X-ray fluorescence. An experimental system based on a hyper pure germanium detector (HPGE) was used to measure the relative K-L and K-M X-ray yields from the photofluorescence of a series of lanthanide elements and compounds. A background subtraction and peak integration strategy was employed which accounted for scattering in the samples and scattering of the flux from the radioisotope photoionization sources. Analysis of the data resulted in a tabulation of relative K/sub #beta#//K/sub #alpha#/ X-ray intensity ratios. The measured relative K/sub #beta#//K/sub #alpha#/ X-ray intensity ratios were compared to the calculated values predicted by the theoretical development of Scofield and the average of previous ...
1987-01-01
K and L x-ray production cross sections excited by 14.00--34.16 MeV #alpha#-particle beams
International Nuclear Information System (INIS)
K and L-shell x-ray production cross sections were measured using #alpha#-particle beams of 14.00 to 34.16 MeV. The K-shell measurements ranged from Z = 20 to Z = 50 and included Ca, Sc, Ti, V, Fe, Ni, Cu, Zn, Ga, Br, Rb, Sr, Y, Mo, Ag, In, and Sn while the L-shell measurements ranged from Z = 55 to Z = 92 and included Cs, Ba, Ce, Gd, Tm, Lu, Au, Pb, Th, and U. Thin metallic foils were used for the measurements and corrections for self-attenuation were negligible. A liquid nitrogen cooled Si(Li) detector and associated pulsed optical electronics were used in detecting x-rays. Absolute cross sections with an uncertainty of +-10 percent are presented for the elements measured. Also smoothed cross sections are presented which were generated by a three term polynomial fit of the experimental data points. By use of available fluorescence yields the K-shell data were converted to ionization cross sections and compared to various theoretical models. The data suggest the necessity for high ...
Energy Technology Data Exchange (ETDEWEB)
ICP emission analyses are prone to errors due to changes in power level, nebulization rate, plasma temperature, and sample matrix. As a result, accurate analyses of complex samples often require frequent bracketing with matrix matched standards. Information needed to track and correct the matrix errors is contained in the emission spectrum. But most commercial software packages use only the analyte line emission to determine concentrations. Changes in plasma temperature and the nebulization rate are reflected by changes in the hydrogen line widths, the oxygen emission, and neutral ion line ratios. Argon and off-line emissions provide a measure to correct the power level and the background scattering occurring in the polychromator. The authors` studies indicated that changes in the intensity of the Ar 404.4 nm line readily flag most matrix and plasma condition modifications. Carbon lines can be used to monitor the impact of organics on the analyses and calcium and argon lines can be ...
1997-10-01
Gaussian pulse decomposition: an intuitive model of electrocardiogram waveforms.
This study presents a novel approach to modeling the electrocardiogram (ECG): the Gaussian pulse decomposition. Constituent waves of the ECG are decomposed into and represented by Gaussian pulses using an iterative algorithm: the chip away decomposition (ChAD) algorithm. At each iteration, a nonlinear minimization method is used to fit a portion of the ECG waveform with a single Gaussian pulse, which is then subtracted from the ECG waveform. The process iterates on the resulting residual waveform until the normalized mean square error is below an acceptable level. Three different minimization methods were compared for their applicability to the ChAD algorithm; the Nelder-Mead simplex method was found to be more noise-tolerant than the Newton-Raphson method or the steepest descent method. Using morphologically different ECG waveforms from the MIT-BIH arrhythmia database, it was demonstrated that the ChAD algorithm is capable of modeling not only normal beats, but ...
International Nuclear Information System (INIS)
The concentration of trace elements in brain sections was measured by synchrotron radiation X-ray fluorescence. The relative concentration was calculated by means of the normalization of Compton scattering intensity approximately 22 keV, after the normalization for collecting time of X-ray spectrum and the counting of the ion chamber, and subtracting the contribution of the polycarbonate film for supporting sample. Furthermore, the statistical evaluation of the element distribution in various regions of the brain sections of the 20-day-old rats was tested. For investigating the distribution of elements in the brain of iodine deficient rats, Wistar rats were fed with iodine deficient diet and deionized water (ID group). The rats were fed the same iodine deficient diet, but drank KIO_3 solution as control (CT group). The results showed that the contents of calcium (Ca) in thalamus (TH) and copper (Cu) and iron (Fe) in cerebral cortex (CX) of ID rats were ...
2004-02-27
Brain SPECT of chronic fatigue syndrome (CFS): SPM analysis of two age groups
International Nuclear Information System (INIS)
Full text: Chronic fatigue syndrome (CFS) is a complex disorder characterised by profound fatigue and neuropsychiatric dysfunction. Previous studies with cerebral perfusion SPECT (rCBF) scans were performed with inhomogeneous patient populations and were not analysed with Statistical Parametric Mapping (SPM). We have used SPM to study subjects with moderate CFS based on the Fukuda criteria, who were not on medication and not depressed, compared to age matched control subjects. An apparent bimodal age distribution has been observed in CFS. Subjects were therefore divided into two age groups: 16-35 or under 35 (17 CFS, 11 control) and 36-61 or over 35 (15 CFS, 15 control). HMPAO brain SPECT was acquired on a 3-head camera. After lower window scatter subtraction, reconstruction with attenuation correction (mu=0.15/cm) and editing of facial activity, scans were spatially normalised (affine + 2x3x2 nonlinear) to SPM's anatomical space. SPM statistical analysis yielded ...
2002-05-04
Absence of isoscalar monopole strength in {sup 56}Fe and {sup 58}Ni
Energy Technology Data Exchange (ETDEWEB)
Measurements with 240 MeV {alpha} particle inelastic scattering with excellent peak/background ratios at small scattering angles including 0{degrees} were made on {sup 56}Fe and {sup 58}Ni using the multipole-dipole-multipole spectrometer at Texas A&M University. Beam was delivered to the spectrometer through a beam analysis system having two bends of 88{degrees} and 87{degrees} respectively. A slit placed after the first 88{degrees} bend was used to define the beam. Slits placed after the second bend (87{degrees}) were used to eliminate slit scattered particles. Comparison of the results of a multiple peak fit to the{sup 58}Ni spectra after continuum subtraction to DWBA calculations revealed about 32% of the E0 EWSR and 58% of the E2 EWSR in the peak, in agreement with previous works. Fits to the angular distribution of the continuum for E{sub x} = 25 MeV show that <15% of the E0 EWSR is present in the continuum. Hence 50% of the EO EWSR must lie above ...
1995-10-01
DoseWatchers - A computer based X ray dose monitoring project in paediatric radiology
International Nuclear Information System (INIS)
Full text: Introduction. Children, especially premature infants and neonates, are at a much higher risk to obtain an X ray induced disturbance of life - particularly cancer. On the one hand this is due to their longer life expectancy and on the other hand it is due to their higher cell proliferation rate. The paediatric radiology unit of the Inselspital Bern recently installed some of the most advanced X ray equipment nowadays available. It is based on the two latest digital technologies: double read computed radiography (CR) and direct digital radiography (DR). Only the implementation of these digital radiography systems permits the digital acquisition and additionally the analysis of acquired data. The systematic analysis of large amounts of biometric data and exposition data is the basis for further dose reduction and a systematic quality control (QC). Patients are increasingly critical concerning ...
2006-11-13
British Library Electronic Table of Contents (United Kingdom)
A web-based decision support tool, zone mapping application for precision farming (ZoneMAP, External Reference Not Shown ), has been developed to automatically determine the optimal number of management zones and delineate them using satellite imagery and field data provided by users. Application rates, such as of fertilizer, can be prescribed for each zone and downloaded in a variety of formats to ensure compatibility with GPS-enabled farming equipment. ZoneMAP is linked to Digital Northern Great Plains, a web-based application which hosts an archive of satellite imagery, as well as high resolution imagery from airborne sensors. Management zones created by ZoneMAP mapped natural variation of the soil organic matter and other nutrients relatively well and were consistent with zone maps cre...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)
2008-12-15
Energy Technology Data Exchange (ETDEWEB)
The paper presents a computer-aided analysis of the combined use of ventilation and structural heat capacity and insulation as a means of saving air-conditioning power in digital telephone exchanges. It is shown that such savings can be effected by increasing air change with outdoor cool air at night, and when feasible, also in daytime, through the air change unit, in a conventional airconditioning cycle. The total thermal time constant (TTTC) method of calculation used enables the evaluation of daily or seasonal heat-flow balance for a given indoor temperature, considering the tendency of the heat capacity of the building and of envelope components to flatten the fluctuations of this temperature.
1984-12-01
Using topographic wetness index in vegetation ecology: does the algorithm matter?
British Library Electronic Table of Contents (United Kingdom)
Abstract Questions: How important is the choice of flow routing algorithm with respect to application of topographic wetness index (TWI) in vegetation ecology? Which flow routing algorithms are preferable for application in vegetation ecology? Location: Forests in three different regions of the Czech Republic. Methods: We used vegetation data from 521 georeferenced plots, recently sampled in a wide range of forest communities. From a digital elevation model, we calculated 11 variations of TWI for each plot with 11 different flow routing algorithms. We evaluated the performance of differently calculated TWI by (1) Spearman rank correlation with average Ellenberg indicator values for soil moisture, (2) Mantel correlation coefficient between dissimilarities of species composition and dissimil...
2010-01-01
Training and information technology issue, 2005
The focus of the May-June issue is on training and information technology. Major articles/reports in this issue include: Communicating effectively, by Alain Bucaille, AREVA; Reputation management, by Susan Brisset, Bruce Power; Contol room and HSI modernization guidance, by Joseph Naser, EPRI; How far are we from public acceptance, by Jennifer A. Biedscheid and Murthy Devarakonda, Washington TRU Solutions LLC; Spent fuel management options, by Brent W. Dixon and Steven J. Piet, Idaho National Laboratory; Industry Awards; A secure energy future for America, by George W. Bush, President, United States of America; Vision of the future of nuclear energy, by Anne Lauvergeon, AREVA; and, Plant profile: strategy for transition to digital, TXU Power.
2005-05-15
The segmental gastrocnemius muscles' flap: A cadaveric study
British Library Electronic Table of Contents (United Kingdom)
The aim of this study was to evaluate the feasibility of splitting each head of the gastrocnemius muscle into two segments. This prospective study was conducted on 35 fresh cadavers with injection of radio-opaque contrast material in the popliteal artery. Seventy medial gastrocnemius and 70 lateral gastrocnemius muscle specimens were obtained. Gastrocnemius intramuscular arterial anatomy was analysed by using the digital X-ray technique. The most common vascular pattern found in this study was both bellies supplied by individual sural arteries, which shows distal bifurcation. The medial sural artery always showed bifurcation in the medial gastrocnemius muscle in both lower limbs, whereas this bifurcation of the lateral sural artery was present in only 87% cases and 13% of cases showed a si...
2011-01-01
The response of small scale rigid targets to shallow buried explosive detonations
British Library Electronic Table of Contents (United Kingdom)
Experimental and computational investigations were performed in order to better understand the mechanical response of rigid targets with various geometries to the detonation of shallow buried explosives. The motion of the targets was measured by use of high-speed digital video photography. This work involved flat targets, targets that were downwardly convex, and targets that were downwardly concave with explosive charges located at various positions beneath the targets. It was observed that, in general, angled hulls - whether downwardly concave or convex - tended to reduce the amount of momentum imparted to the center of mass of the targets. Computations were performed by use of an arbitrary Langrangian-Eulerian treatment in a nonlinear finite element code. A model based on quasi-static te...
2011-01-01
RooStats is a project to create advanced statistical tools required for the analysis of LHC data, with emphasis on discoveries, confidence intervals, and combined measurements. The idea is to provide the major statistical techniques as a set of C++ classes with coherent interfaces, which can be used on arbitrary model and datasets in a common way. The classes are built on top of RooFit, which provides a very convenient functionality for modeling the probability density functions or the likelihood functions, required as inputs for any statistical technique. Furthermore, RooFit provides the functionality for easily creating models, for analysis combination and for digital publication of the likelihood function and the data. We will present in detail the design and the implementation of the different statistical methods of RooStats. These include various classes for interval estimation and for hypothesis test depending on different statistical techniques such as those ...
2010-01-01
The Lithium future-resources, recycling, and the environment
British Library Electronic Table of Contents (United Kingdom)
Abstract:- The demand for Lithium-ion batteries as a major power source in portable electronic devices and vehicles is rapidly increasing. I use cumulative data of vehicle, mobile phone, laptop, and digital camera production to show that demand will overshoot the available global Lithium resources before 2025. Even if 100% of all Lithium-ion batteries were recycled today, recycling could not prevent this resource depletion in time. As the increasing Lithium scarcity will increase the price, it will be feasible to mine diluted resources with a strong environmental impact. I highlight these impacts in Lithium-rich Bolivia, the potential new -Saudi Arabia of Lithium.- Lithium extraction is likely to cause substantial water pollution, and-through impacts on native diversity-facilitate human he...
2011-01-01
Temperature problems in mine rescue
Energy Technology Data Exchange (ETDEWEB)
Describes temperature and humidity sensing devices used in mine rescue operations. Chemical indicators use chemical substances that melt at predetermined temperatures and display the actual temperature in the range of 40-50 C. Electronic temperature monitoring devices release acoustic signals as soon as a temperature of 40 or 45 C has been exceeded. A more recent piece of equipment combines the ULR rescue communication set with remote temperature sensing. A digital meter that measures temperature and humidity in the range of -100 to +200 C and 3 to 98% respectively has also been developed. The Central Mine Rescue Station in Bytom, Poland has developed equipment that permits body temperature and pulse rate of a rescuer to be measured and transmitted by radio over a distance of up to 50 m. Safe threshold values can be set for each individual rescuer.
1990-08-01
Surface characteristics and overlaying properties of flat-pressed wood plastic composites
British Library Electronic Table of Contents (United Kingdom)
This study evaluated surface characteristics and overlaying properties of wood plastic composite (WPC) panels made from dry-blended rubber wood fiber-polypropylene (PP) powder formulations using a conventional flat-press process under laboratory conditions. Three levels of rubberwood fibers (Hevea brasiliensis), 40%, 50%, and 60%, based on the composition by weight, were mixed with the PP powder without and with 3% (based on weight) maleic anhydride grafted PP (MAPP) as a coupling agent. Contact angle measurements on the WPC samples were performed using a goniometer connected with a digital camera which collected one image per second. Roughness measurements, average roughness (R a), mean peak-to-valley height (R z), and maximum roughness (R y), were taken from the sanded samples along and ...
2011-01-01
Studies on ball screw type damper with centrifugal brakes
International Nuclear Information System (INIS)
The effects of vibration isolation of the new type of mechanical damper applied to a single-degree-of-freedom system and a simple beam are discussed numerically and experimentally. The damper is composed of a ball screw, a flywheel and centrifugal brakes, and possesses nonlinear characteristics. The Continuous System Simulation Language is used for the digital simulations of the nonlinear vibration systems. The results may be summarized as follows: (1) The damper is effective for suppressing the amplitude of the single-degree-of-freedom system as well as of the beam at the point of attachment of the damper, at the resonances. (2) The damper approaches a snubber for smaller values of lead L of the ball screw (or larger values of moment of inertia J of the flywheel), and acts like a damper whose damping force is proportional to the square of the velocity for larger values of L (or smaller values of J). (author).
1986-01-01
State-of-the-Art developments in accelerator controls at the APS.
Energy Technology Data Exchange (ETDEWEB)
The performance requirements of the Advanced Photon Source (APS) challenge the control system in a number of areas. This paper will review a few applications of advanced technology in the control and monitoring of the APS. The application of digital signal processors (DSPs) and techniques will be discussed, both from the perspective of a large distributed multiprocessor system and from that of embedded systems. In particular, two embedded applications will be highlighted, a beam position monitor processor and a DSP-based power supply controller. Fast data distribution is often a requirement. The application of a high-speed network based on reflective memory will also be discussed in the context of the APS global orbit feedback system. Timing systems provide opportunities to apply technologies such as high-speed logic and fiber optics. Examples of the use of these technologies will also be included. Finally, every modern accelerator control system of any size ...
1999-04-13
Spray, combustion, and heat transfer studies in a Ricardo hydra direct-injection diesel engine
Energy Technology Data Exchange (ETDEWEB)
The spray and combustion development in a single-cylinder, direct-injection diesel engine equipped with optical access was examined using a number of complementary techniques. A laser imaging system, based around a pulsed copper-vapour laser synchronised to an intensified CCD camera, was used to obtain images of the four fuel sprays prior to combustion, and to determine the tip penetration of each spray as a function of crankangle. The surface heat flux to the wall of the piston bowl was measured by placing a fast-response thermocouple at the impingement point of one of the sprays, and a two-colour imaging system was used to obtain digital images of the flame temperature and equivalent soot distribution in the cylinder. (author)
1996-12-31
Single-pole switching schemes for EHV transmission systems
Energy Technology Data Exchange (ETDEWEB)
Recognizing that a high percentage of transmission-line faults are single-phase to earth and temporary in nature, provides the impetus for considering single-pole switching as a means to enhance the reliability of EHV transmission systems. The effectiveness of single-pole switching schemes is largely determined by the speed with which the secondary arcs extinguish, and hence allow system restoration. Simulation techniques that enable better prediction of the faulted-system response are of obvious importance to the design and assessment of the various single-pole switching scheme applications. In this thesis, digital methods are developed to enable the faulted response of EHV systems to be simulated for a variety of different single-pole switching schemes. These include conventional single-pole switching, the hybrid method of autoreclosure, the neutral switched reactor, and the High Speed Grounding Switch implementations. The work is of importance to system ...
1986-01-01
Simulation study of feedback systems based on a two-tap FIR filter. Under beam-beam collisions
Energy Technology Data Exchange (ETDEWEB)
The performance of bunch-feedback systems based on two-tap FIR filters is discussed, particularly for transverse cases. Since they are the simplest type of FIR digital filters, the two-tap FIR filters should be suited to systems that require a very fast processing speed. However, in these feedback systems, a bunch must turn along a ring several times from the position-measurement to feedback kicking. Within these turns, irregular phase-jumps in the betatron motion can occur, due to several causes, such as the wake forces and beam-beam force. The discussion given in this paper is focussed on the effect of beam-beam collisions on these feedback systems. Based on linear theory and simulation studies, it has been found that these feedback systems can work with good performance, even under the influence of a strong beam-beam force. (author)
1998-04-01
Security of mobile agents: a new concept of the integrity protection
The recent developments in the mobile technology (mobile phones, middleware) created a need for new methods of protecting the code transmitted through the network. The proposed mechanisms not only secure the compiled program, but also the data, that can be gathered during its "journey". The oldest and the simplest methods are more concentrated on integrity of the code itself and on the detection of unauthorized manipulation. Other, more advanced proposals protect not only the code but also the execution state and the collected data. The paper is divided into two parts. The first one is mostly devoted to different methods of securing the code and protecting its integrity; starting from watermarking and fingerprinting, up to methods designed specially for mobile agent systems: encrypted function, cryptographic traces, time limited black-box security, chained-MAC protocol, publicly-verifiable chained digital signatures The second part presents new concept for ...
2005-01-01
Resonant overvoltage phenomena caused by transmission line faults
Energy Technology Data Exchange (ETDEWEB)
Resonant overvoltages in EHV transformers can be initiated by transmission line faults. A series of field tests were performed on the 151 mile long Kammer-Marysville 765 kV line in which a sequence of single line to ground faults were applied to one outside phase at 4 different locations. Fault location criteria and fault initiation procedures are presented. Oscillograms recorded the 3 phase response at both terminals of the line; one is transformer terminated, the other is open-ended. A frequency spectrum analysis of the waveforms is provided showing transient frequencies of sufficient magnitude and duration near the EHV transformer's resonant frequency to stimulate internal winding resonant overvoltages. Digital computer studies are presented and agree with the field tests quite favorably.
1985-09-01
Reinforced concrete beam-column joint strengthened with carbon fiber reinforced polymer
British Library Electronic Table of Contents (United Kingdom)
An effective rehabilitation strategy is proposed to enhance the strength and stiffness of the beam-column joint in this study. An analytical model is proposed to predict the column shear of the joints strengthened with carbon fiber reinforced polymer (CFRP). Three full scale interior beam-column joints, including two specimens strengthened with CFRP and one prototype specimen, are tested in this study. The specimens are designed to represent the pre-seismic code design construction in which there is no transverse reinforcement. A new optical non-contact technique, digital image correlation (DIC), which can measure the full strain field of specimen, is used to measure and observe the full strain field of the joint. The experimental results show that the beam-column joints strengthened with ...
2010-01-01
Real-time orbit feedback at the APS.
Energy Technology Data Exchange (ETDEWEB)
A real-time orbit feedback system has been implemented at the Advanced Photon Source in order to meet the stringent orbit stability requirements. The system reduces global orbit motion below 30Hz by a factor of four to below 5{micro}m rms horizontally and 2{micro}m rms vertically. This paper focuses on dynamic orbit stability and describes the all-digital orbit feedback system that has been implemented at the APS. Implementation of the global orbit feedback system is described and its latest performance is presented. Ultimately, the system will provide local feedback at each x-ray source point using installed photon BPMs to measure x-ray beam position and angle directly. Technical challenges associated with local feedback and with dynamics of the associated corrector magnets are described. The unique diagnostic capabilities provided by the APS system are discussed with reference to their use in identifying sources of the underlying orbit motion.
1998-06-18
International Nuclear Information System (INIS)
Results of ongoing research project at the McMaster Nuclear Reactor Facility on real-time neutron radiography for the visualization of interfacial geometry, movements and phase distributions in gas-liquid and gas-liquid-metal multi-phase flows are presented. Experiments were conducted with bubble column tubes with boiling liquid nitrogen, air-water and air-mercury mixtures. Discussions are also focused on air-water flowing within a tube containing a CANDU type 37 rod fuel bundle assembly positioned both horizontally and vertically. Computer processing using a digital image format to enhance the real-time images was used. Imaging techniques include frame averaging, background substraction, edge enhancement (spatial filtering), contrast enhancement and video densitometry. (orig.).
1989-10-01
Rapid and precise measurement of flatband voltage
The paper outlines the design, principles of operation, and calibration of a five-IC network intended to give a rapid, precise, and automatic determination of the flatband voltage of MOS capacitors. The basic principle of measurement is to compare the analog output voltage of a capacitance meter - which is directly proportional to the capacitance being measured - with a preset or dialed-in voltage proportional to the calculated flatband capacitance by means of a comparator circuit. The bias to the MOS capacitor supplied through the capacitance meter is provided by a ramp voltage going from a negative toward a positive voltage level and vice versa. The network employs two monostable multivibrators for reading and recording the flatband voltage and for resetting the initial conditions and restarting the ramp. The flatband voltage can be held and read on a digital voltmeter.
1976-05-01
British Library Electronic Table of Contents (United Kingdom)
Bank sediments along a 40km reach of the South River, downstream of Waynesboro, VA, store mercury from historical contamination as a result of textile manufacturing. Knowledge of the rate at which contaminated sediment is released to the stream channel through bank erosion is required to implement restoration programs designed, for example, to minimize its ecological impact and to reduce risk to human health. Digitized stream channel boundaries based on visual interpretations of georeferenced aerial imagery from 1937 and 2005 were compared to calculate a minimum estimate of the total area of bank sediment eroded between Waynesboro and Port Republic, Virginia. Estimates of riverbank height were extracted from aerial LIDAR data, allowing areal estimates of bank retreat to be converted to vol...
2009-01-01
Psychological test performance in foundry workers exposed to low levels of manganese
Energy Technology Data Exchange (ETDEWEB)
A sample of 30 manganese-exposed foundry workers from two Swedish plants were examined with a partly computerized psychological test battery, comprised of 10 performance tests. Performance of the manganese-exposed workers was compared to that of a matched control group of 60 workers. Matching criteria were age, geographical area, type of work, and the results on a test of verbal comprehension. Performance of the exposed workers was inferior to that of the control group on tests of simple reaction time, digit span, and finger tapping. No correlations were found between performance and the present manganese exposure levels or the number of years employed in manganese work. The results seem to indicate that the present exposure standards for manganese, in Sweden 2.5 mg/m3 and in most other countries 5 mg/m3, are not sufficient to protect workers from negative effects on performance capacity.
1990-11-01
Energy Technology Data Exchange (ETDEWEB)
Itaipu Binacional has taken a decision of executing a technological updating for the energy measurement system through the substitution of the current system by other one equipped with digital devices. The main reasons for that were the following: a) The equipment in operation were of an outdated generation b) The accuracy class of the existing equipment was of 0.5%, but the tendency for invoicing measurements was to install meters with accuracy class of 0.2% in the enterprises c) The requirements of ONS/MAE, in Brazil, which establishes the minimum requisites to be attended by invoicing measurement systems.
2001-07-01
Energy Technology Data Exchange (ETDEWEB)
In this article a production method of a magnetorheological suspension composed with silicon steel particles of size 0.1-0.15 mm and 4% silicon content is described. Steel particles were dispersed in a conducting carrier of a by mixture of graphite particles with size 2-5 {mu}m and cedar wood oil. The filling factor of the suspension with the silicon steel particles and with graphite particles amounted to 0.25-0.40. Samples of this suspension were placed in a rectangular vessel with electrodes and used for the investigation of the Hall effect in magnetic field with induction 0-8 T, generated by Bitter-type magnet. A non-linear dependence of Hall voltage on the induction of the applied magnetic field and a hysteresis loop of this voltage in the shape of inclined digit eight were found. The causes of the observed effects is the ordering of silicon steel particles and graphite particles along the side of magnetic field lines.
2003-08-01
Energy Technology Data Exchange (ETDEWEB)
Reliable facility of cyclotron-based real time neutron radiography system has been developed and applied to some industrial components. The equipment for neutron fluoroscopy is based on a sub-compact cyclotron and a LiF/ZnS (Ag) fluorescent screen viewed by a silicon intensifier target TV camera. The real time image is monitored on a CRT, recorded with a standard video recorder and processed by a digital image processor. The effectiveness of our real time neutron radiograph has been demonstrated to be applicable to not only the dynamic observation but also the magnifying and stereoscopic observation of fluoroscopic images.
1987-03-01
Mining Knowledge in Astrophysical Massive Data Sets
Modern scientific data mainly consist of huge datasets gathered by a very large number of techniques and stored in very diversified and often incompatible data repositories. More in general, in the e-science environment, it is considered as a critical and urgent requirement to integrate services across distributed, heterogeneous, dynamic "virtual organizations" formed by different resources within a single enterprise. In the last decade, Astronomy has become an immensely data rich field due to the evolution of detectors (plates to digital to mosaics), telescopes and space instruments. The Virtual Observatory approach consists into the federation under common standards of all astronomical archives available worldwide, as well as data analysis, data mining and data exploration applications. The main drive behind such effort being that once the infrastructure will be completed, it will allow a new type of multi-wavelength, multi-epoch science which can only be barely ...
2010-01-01
Method for the reduction of image content redundancy in large image databases
Energy Technology Data Exchange (ETDEWEB)
A method of increasing information content for content-based image retrieval (CBIR) systems includes the steps of providing a CBIR database, the database having an index for a plurality of stored digital images using a plurality of feature vectors, the feature vectors corresponding to distinct descriptive characteristics of the images. A visual similarity parameter value is calculated based on a degree of visual similarity between features vectors of an incoming image being considered for entry into the database and feature vectors associated with a most similar of the stored images. Based on said visual similarity parameter value it is determined whether to store or how long to store the feature vectors associated with the incoming image in the database.
2010-03-02
British Library Electronic Table of Contents (United Kingdom)
Terrain attributes derived from digital elevation models have been used widely for mapping soil organic matter (SOM). Among these attributes, the topographic wetness index (TWI), an index for quantitatively indicating the balance between water accumulation and drainage conditions at the local scale, has been shown to correlate with SOM. However, TWIs used in most studies are calculated using a single-flow-direction (SFD) algorithm, which assumes that all water from a grid cell flows into only one neighboring cell. This assumption is not always valid, especially in areas with low relief where movement of water may be divergent. To overcome this SFD limitation, a multiple-flow-direction (MFD) algorithm has been developed, which distributes flow from a grid cell to several downslope neighbors...
2010-01-01
Liquid metal flow measurement by neutron radiography
Energy Technology Data Exchange (ETDEWEB)
Visualization of a liquid metal flow and image processing methods to measure the vector field are carried out by real-time neutron radiography. The JRR-3M real-time thermal neutron radiography facility in the Japan Atomic Energy Research Institute was used. Lead-bismuth eutectic was used as a working fluid. Particles made from a gold-cadmium intermetallic compound (AuCd{sub 3}) were used as the tracer for the visualization. The flow vector field was obtained by image processing methods. It was shown that the liquid metal flow vector field was obtainable by real-time neutron radiography when the attenuation of neutron rays due to the liquid metal was less than l/e and the particle size of the tracer was larger than one image element size digitized for the image processing. (orig.).
1996-07-21
Liquid metal flow measurement by neutron radiography
International Nuclear Information System (INIS)
Visualization of a liquid metal flow and image processing methods to measure the vector field are carried out by real-time neutron radiography. The JRR-3M real-time thermal neutron radiography facility in the Japan Atomic Energy Research Institute was used. Lead-bismuth eutectic was used as a working fluid. Particles made from a gold-cadmium intermetallic compound (AuCd_3) were used as the tracer for the visualization. The flow vector field was obtained by image processing methods. It was shown that the liquid metal flow vector field was obtainable by real-time neutron radiography when the attenuation of neutron rays due to the liquid metal was less than l/e and the particle size of the tracer was larger than one image element size digitized for the image processing. (orig.).
1996-07-01
Land use change in a biofuels hotspot: The case of Iowa, USA
British Library Electronic Table of Contents (United Kingdom)
This study looks at the land use impact of the biofuels expansion on both the intensive and extensive margin, and its environmental consequences. We link economic, geographical and environmental models by using spatially explicit common units of analysis and use remote sensing crop cover maps and digitized soils data as inputs. Land use changes are predicted via economic analysis of crop rotation choice and tillage under alternative crop prices, and the Environmental Policy Integrated Climate (EPIC) model is used to predict corresponding environmental impacts. The study focuses on Iowa, which is the leading biofuels hotspot in the U.S. due to intensive corn production and the high concentration of ethanol plants that comprise 28% of total U.S. production. We consider the impact of the biof...
2011-01-01
Kinetics of gypsum crystal growth on a reverse osmosis membrane
British Library Electronic Table of Contents (United Kingdom)
The development of calcium sulfate dihydrate (gypsum) mineral scale in reverse osmosis (RO) membrane desalting was investigated by direct real-time observation of crystal growth. Gypsum scaling studies were conducted in a specially modified plate-and-frame reverse osmosis cell fitted with an optical window, with dark-field membrane lighting arrangement within the membrane cell to enhance crystal boundaries and allow recording of digital surface images magnified through an optical microscope. The evolution of the surface number density (SND) of gypsum crystals resembled a sigmoidal population growth process with an increasing rate of crystal formation at higher solution supersaturation (with respect to gypsum) at the membrane surface. The rate of formation of new crystals declined as the su...
2008-01-01
British Library Electronic Table of Contents (United Kingdom)
Orthogonal frequency division multiplexing (OFDM) can fully use the frequency band and transmit data at high speeds. The ADSP-TS101 is a high performance digital signal processor (DSP) with good properties that include parallel processing and a high speed. Aimed at the real-time processing requirement of the OFDM algorithm, an underwater acoustic communication system with real-time processing capability is carried out. The system is mainly composed of multiple ADSP-TS101s, a multi-channel synchronous sample module and a field programmable gate array (FPGA) chip. The multiprocessor structure is made up of a cluster/data flow associated multiprocessing parallel processing structure as the operation kernel, and a multi-channel synchronous sample module is designed to realize no phase warp amo...
2007-01-01
Idealized gas turbine combustor for performance research and validation of large eddy simulations.
This paper details the design of a premixed, swirl-stabilized combustor that was designed and built for the express purpose of obtaining validation-quality data for the development of large eddy simulations (LES) of gas turbine combustors. The combustor features nonambiguous boundary conditions, a geometrically simple design that retains the essential fluid dynamics and thermochemical processes that occur in actual gas turbine combustors, and unrestrictive access for laser and optical diagnostic measurements. After discussing the design detail, a preliminary investigation of the performance and operating envelope of the combustor is presented. With the combustor operating on premixed methane/air, both the equivalence ratio and the inlet velocity were systematically varied and the flame structure was recorded via digital photography. Interesting lean flame blowout and resonance characteristics were observed. In addition, the combustor exhibited a large region of ...
2007-03-01
GPS and Google Earth based 3D assisted driving system for trucks in surface mines
British Library Electronic Table of Contents (United Kingdom)
In order to reduce the number of surface mining accidents related to low visibility conditions and blind spots of trucks and to provide 3D information for truck drivers and real time monitored truck information for the remote dispatcher, a 3D assisted driving system (3D-ADS) based on the GPS, mesh-wireless networks and the Google-Earth engine as the graphic interface and mine-mapping server, was developed at Virginia Tech. The research results indicate that this 3D-ADS system has the potential to increase reliability and reduce uncertainty in open pit mining operations by customizing the local 3D digital mining map, constructing 3D truck models, tracking vehicles in real time using a 3D interface and indicating available escape routes for driver safety.
2010-01-01
Focused ion beam sculpting curved shapes.
Energy Technology Data Exchange (ETDEWEB)
A focused ion beam (FIB) is used to accurately sculpt predetermined micron-scale, curved shapes in a number of solids. Using a digitally scanned ion beam system, various features are sputtered including hemispheres and sine waves having dimensions from 1-50 {micro}m. Ion sculpting is accomplished by changing pixel dwell time within individual boustrophedonic scans. The pixel dwell times used to sculpt a given shape are determined prior to milling and account for the material-specific, angle-dependent sputter yield, Y({theta}), as well as the amount of beam overlap in adjacent pixels. A number of target materials, including C, Au and Si, are accurately sculpted using this method. For several target materials, the curved feature shape closely matches the intended shape with milled feature depths within 5% of intended values.
2005-02-01
Focused ion beam preparation of inclined planes in semiconductor materials
International Nuclear Information System (INIS)
Focused ion beam (FIB) micromachining has been used to produce inclined planes on semiconductor surfaces. A 10 keV FIB system, utilising a Ga"+ liquid metal ion source (LMIS), was employed. The ramped surfaces were prepared by digitally deflecting the ion beam in a serpentine fashion over a rectangular area and incrementing the time the beam spends at a pixel, dwell time, line by line. For the conditions used, control in micromachining the inclination of the ramps to the starting horizontal surface is of the order of 1 arc s per scan of the FIB over the area of interest. The possibility of using such surfaces prepared by FIB, along with vacuum growth techniques such as molecular beam epitaxy (MBE), for application to strain relief structures and lateral device production is discussed. (author).
Extracting mining subsidence land from remote sensing images based on domain knowledge
Energy Technology Data Exchange (ETDEWEB)
Extracting mining subsidence land from remote sensing (RS) images is one of important research contents for environment monitoring in mining area. The accuracy of traditional extracting models based on spectral features is low. In order to extract subsidence land from RS images with high accuracy, some domain knowledge should be imported and new models should be proposed. This paper, in terms of the disadvantage of traditional extracting models, imports domain knowledge from practice and experience, converts semantic knowledge into digital information, and proposes a new model for the specific task. By selecting the Luan mining area as a study area, this new model is tested based on GIS and related knowledge. The result shows that the proposed method is more precise than traditional methods and can satisfy the demands of land subsidence monitoring in mining area. 10 refs., 4 figs., 1 tab.
2008-06-15
Extensions to the VME hardware and software standards for the physics community
Energy Technology Data Exchange (ETDEWEB)
With the ubiquitous availability of commercial VME modules and interface chips many experiments in all branches of Experimental Physics are turning to VME as the module packaging and backplane protocol of choice for application specific modules. The current VME backplane, electrical, and mechanical standards are clearly lacking when it comes to implementing the analogue and digital front end modules that Physics experiments rely on to provide the needed high speed and intelligent solutions to their data collection requirements. To address these needs the European ESONE and American VME-P committees are collaborating with the ANSII and ISO standards committees, and the VME VITA/VSO manufacturers associations, to define standard extensions to the VME protocols for such HEP needs as ``sparse data scans``, standard uses and implementations of previously user defined pins and connectors, standardization of the 9U form factor VME cards etc. This paper reports on the ...
1995-10-01
Evaluation of routine telephone transmission of nuclear medicine studies
Energy Technology Data Exchange (ETDEWEB)
Rapid and reliable transmission of nuclear medicine studies using conventional telephone lines and commercially available modems and computer systems has been accomplished through use of software developed within the authors' hospital. Original digital images of all-night and weekend studies, acquired on any of the acquisition computers from different manufacturers, are now routinely sent for remote reading at the physician's home. Data, software, and letters are routinely exchanged using modems and standard telephone lines with a sister institution in Haifa, Israel. The software has been designed to achieve no loss data compression and minimal turnaround time loss. Thus, an average lung perfusion image or gallbladder study requires about 1-3 minutes of transmission time. Full analysis and display software is available on the remote computer.
1989-01-01
Evaluation of digital radiography (Fuji computed radiography) for portable chest radiographs in ICU
Energy Technology Data Exchange (ETDEWEB)
To evaluate the usefulness of portable chest radiographs by Fuji computed radiography (FCR) in ICU, FCR radiographs of 56 patients who were admitted to General Intensive Care Unit of Keio University Hospital were compared with the conventional portable images. Because FCR could show two differently processed images in one film and allowed a wide range of image reproduction, visualization of the trachea, bone soft tissues and catheters by FCR was easier than that by the conventional radiography. Repeated radiographs by FCR had similar optical densities and limited exposure errors. Furthermore, radiation was reduced than that of the conventional radiography. In conclusion, FCR is thought to be a useful technique for portable chest radiography in ICU patients. (author).
1992-12-01
Evaluation of digital radiography (Fuji computed radiography) for portable chest radiographs in ICU
International Nuclear Information System (INIS)
To evaluate the usefulness of portable chest radiographs by Fuji computed radiography (FCR) in ICU, FCR radiographs of 56 patients who were admitted to General Intensive Care Unit of Keio University Hospital were compared with the conventional portable images. Because FCR could show two differently processed images in one film and allowed a wide range of image reproduction, visualization of the trachea, bone soft tissues and catheters by FCR was easier than that by the conventional radiography. Repeated radiographs by FCR had similar optical densities and limited exposure errors. Furthermore, radiation was reduced than that of the conventional radiography. In conclusion, FCR is thought to be a useful technique for portable chest radiography in ICU patients. (author).
1992-01-01
British Library Electronic Table of Contents (United Kingdom)
Little is known about the rates of establishment and clonal spread of invasive plants on a landscape scale. This knowledge is necessary for reconstructing and predicting invasions, for example of the alien shrub Rosa rugosa. A series of aerial photographs (1986, 1999, 2002, 2004, 2006) were used to map the species in coastal dunes of north-western Denmark (2354ha), and all R. rugosa patches (1321) were recorded with GPS in 2004 and 2007. The 2004 records were used to digitize 82-161 distinct patches on the photographs. The increase in patch sizes from the older to the younger photographs was used to calculate a lateral clonal spread rate (0.42myear^-^1). Relative area increment by clonal spread was 16.4% per year, decreasing exponentially with patch size due to constant clonal lateral spre...
2009-01-01
British Library Electronic Table of Contents (United Kingdom)
Statement of problem Inadequate dimensioning of the connectors in a cantilever cross-arch fixed dental prosthesis (FDP) in perioprosthetic patients jeopardizes the prognosis of the restoration. Purpose The purpose of this study was to investigate the effect of increasing the vertical dimension (VD) on the maximum stress developed within the connectors during the static loading of a cross-arch FDP extended as a 1- and 2-unit cantilever. Material and methods Six digital models were developed, derived from a 3-dimensional (3-D) initial model. In the initial model, the teeth were prepared for metal ceramic restorations and splinted with a cross-arch FDP, extended as a 1- or 2-unit cantilever. The VDs of the connectors proximal to the retaining abutment were 3, 4, or 5 mm. A 3-D finite element ...
2010-01-01
ECOTRONIC - an electronic system for mixture formation
Energy Technology Data Exchange (ETDEWEB)
Fhe ECOTRONIC system developed by Bosch und Pierburg System oHG is an electronic system for mixture formation for Otto-cycle engines complying with high operational requirements. Engineers incorporated electronic control of the quantity of mixture and mixture enrichment for supplementary functions into a reliable, low-cost system, which will also comply with future requirements concerning fuel consumption, emissions and driveability. The author of the present article reduces the carburetor down to its basic systems, explains how supplementary functions were converted from mechanical to either open or closed-loop electronic control, and describes the newly developed actuators, the control unit making use of digital technology, and the results achieved.
1984-02-01
Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)
Energy Technology Data Exchange (ETDEWEB)
Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical conditions were determined. (author).
1991-12-01
Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)
International Nuclear Information System (INIS)
Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical conditions were determined. (author).
1991-01-01
Development of the high sensitivity real-time neutron radiography for low-flux neutron sources
Energy Technology Data Exchange (ETDEWEB)
The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose of developing a system with higher sensitivity, consideration of neutron statistics would be important. ...
1994-08-01
Development of the high sensitivity real-time neutron radiography for low-flux neutron sources
International Nuclear Information System (INIS)
The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose of developing a system with higher sensitivity, consideration of neutron statistics would be important. ...
1994-01-01
Development of linear flow rate control system for eccentric butter-fly valve
Energy Technology Data Exchange (ETDEWEB)
Butter-fly valves are advantageous over gate, globe, plug, and ball valves in a variety of installations, particularly in the large sizes. The purpose of this project development of linear flow rate control system for eccentric butter-fly valve (intelligent butter-fly valve system). The intelligent butter-fly valve system consist of a valve body, micro controller. The micro controller consist of torque control system, pressure censor, worm and worm gear and communication line etc. The characteristics of intelligent butter-fly valve system as follows: Linear flow rate control function. Digital remote control function. guard function. Self-checking function. (author)
1999-12-01
Detect and classify faults using neural nets
Energy Technology Data Exchange (ETDEWEB)
The analysis of transmission line faults is essential to the proper performance of the power system. It is required if protective relays are to take the appropriate action and in monitoring the performance of relays, circuit breakers, and other protective and control elements. The detection and classification of transmission line faults is a fundamental component of such fault analysis. Another application of fault analysis is in software packages for automated analysis of digital fault recorder (DFR) files. Recently, such a package, called DFR Assistant, was developed for substation applications. This program can be installed locally in a substation, in which case it is connected directly to the DFR via a high speed parallel link, or it can be installed at a central station, in which case it can be configured to automatically analyze events coming from all DFRs.
1996-10-01
Crack tip opening angle measurement through a girth weld in an X100 steel pipeline section
British Library Electronic Table of Contents (United Kingdom)
ABSTRACT Crack tip opening angle (CTOA) is becoming one of the most accepted methods for characterizing fully plastic fracture. It provides a measure of the resistance to fracture for a material in cases where there is a large degree of stable-tearing crack extension during the fracture process. Our current pipeline research uses the CTOA test as an alternative, or addition, to the CTOD (crack tip opening displacement) and the fracture energy characterization provided by the J-integral approach. A test technique was developed for measurement of CTOA that uses a modified double cantilever beam (MDCB) specimen. A digital camera and image analysis software were used to record the progression of the crack tip and to estimate the CTOA. In this article, CTOA data on crack growth orientations per...
2008-01-01
Common aperture multispectral sensor flight test program
Energy Technology Data Exchange (ETDEWEB)
This paper will provide an overview of the Common Aperture Multispectral Sensor (CAMS) Hardware Demonstrator. CAMS is a linescanning sensor that simultaneously collected digital imagery over the Far-IR (8 to 12 {mu}m) and visible spectral (0.55 to 1.1 PM) spectral bands, correlated at the pixel level. CAMS was initially sponsored by the U.S. Naval Air System Commands F/A-18 program office (PMA-265). The current CAMS field tests are under the direction of Northrop-Grumman for the Defense Nuclear Agency (DNA) in support of the Follow-On Open Skies Sensor Evaluation Program (FOSEP) and are scheduled to be conducted in April 1996. 8 figs., 4 tabs.
1996-11-01
Color recognition system for urine analyzer
In order to increase the speed of photoelectric conversion, a linear CCD is applied as the photoelectric converter instead of the traditional photodiode. A white LED is used as the light source of the system. The color information of the urine test strip is transferred into the CCD through a reflecting optical system. It is then converted to digital signals by an A/D converter. The test results of urine analysis are obtained by a data processing system. An ARM microprocessor is selected as the CPU of the system and a CPLD is employed to provide a driving timing for the CCD drive and the A/D converter. Active HDL7.2 and Verilog HDL are used to simulate the driving timing of the CPLD. Experimental results show that the correctness rate of the test results is better than 90%. The system satisfies the requirements of the color information collection of urine analyzer.
2010-08-01
Characterization of surface defects after flanging of metallic sheets
British Library Electronic Table of Contents (United Kingdom)
This paper deals with surface defects of automobile outer panels, which alter significantly the vehicle quality. Such defects occur during springback, after forming or flanging steps, and are characterized by concave depression of small amplitude over the convex shape of the part. The aim of this work is to reproduce at the laboratory scale a surface defect that occurs after flanging on a geometry similar to a door upper corner. A dedicated device has been designed in order to generate small size surface defects during flanging of metallic thin sheets. The outer surface of the sample was digitalized and the spatial geometry of the defect was evaluated from curvature change along 2D profiles. This study shows that the flanging height does not influence significantly the surface defect geome...
2011-01-01
Course website from Cambridge on ceramic materials. This site contains eight lectures in PDF format (Adobe Reader required), two question sheets, five practicals (including answers), digital movies and further useful links. "There is a strong relationship between the structure of a material and its physical properties. The properties of a material whether mechanical, electrical, optical or magnetic, determine how it can be used in practical applications. In this course, the focus is on the structure / property relationship for ionic materials with electrical properties utilised in various transducer devices. The materials considered include perovskites, which have special polarisation properties exploited in ferroelectric, pyroelectric and piezoelectric devices. Other oxides, such as zirconia, have structures permitting rapid diffusion of ions, making them suitable for use in sensors, fuel cells and batteries. The scientific principles underlying the properties of ...
2007-02-01
International Nuclear Information System (INIS)
In order to investigate the behaviour of the turbine control system during strong pendulum motions, an analysis is carried out using a digital computer program by which the reactor, the turbine, the generator and, in a simplified way, the network can be simulated to the necessary degree. Plotter pictures can show the main physical quantities. In all cases, the turbine control system should be able to distinguish between strong pendulum amplitude with acceleration of the rotational angles and sudden release criteria. This demand can be satisfied by a simple adjustment in the Kraftwerk Union turbine control system. Only a few seconds after shut-off of a severe network failure, the turbines are back to their rated power, thus contributing to reliability of supply in this critical network situation. (orig.).
1978-11-24
Automatic calculation of bathymetry for coastal hydrodynamic models
British Library Electronic Table of Contents (United Kingdom)
A methodology is proposed to facilitate the construction of gridded bathymetry data for the use of hydrodynamic models on the continental shelf. It relies on the carrying out of three successive tasks: (1) automatic selection of records of better quality among multiple sets of overlapping data; (2) elimination of data points located on land; and (3) taking into account the shoreline as bathymetric data. Algorithms are proposed to perform sorting of the records according to their quality as well as masking by the coastline. The suggested method facilitates the updating of bathymetry data and optimizes their use. It enables automatic execution of all the tasks and building of new digital bathymetry models in a few hours, without action from the operator. The method has been tested many times...
2011-01-01
Application of remote sensing and geophysics to the detection and monitoring of acid mine drainage
Energy Technology Data Exchange (ETDEWEB)
The results of a study on the application of remote sensing and geophysical methods for the detection and monitoring of acid mine drainage (AMD) are summarized, with emphasis on those that appear most suitable. The study consisted of a literature review, an information survey of users and suppliers, and discussions with various experts. Space-borne sensors, airborne sensors, airborne videography and digital frame cameras, spectroradiometers, radar, and photographic data are considered. Geophysical methods are effective for measurement of sulphides, areas of active chemical oxidation, acid mine drainage, and contaminated ground water movement. The popularity and effectiveness of various geophysical methods are rated for AMD applications. 25 refs., 1 fig., 3 tabs.
1995-06-01
Application of PDA forest fire monitoring based on web service technology
British Library Electronic Table of Contents (United Kingdom)
The difficulty in information communication and sharing are major problems for forest fire monitoring and early warning in China. As authors, we applied web service technology to a personal digital assistant (PDA) forest fire monitoring system and propose the framework of a monitoring system based on service-oriented architecture (SOA). At the same time, we describe the composition and function of web services from a server side and a client side. The method for developing a web service invocation engine on the PDA is introduced in detail. Finally, an example of a fire danger rating and fire weather services system are established, based on the Beijing Forest Fire Control System. The results show that the PDA forest fire monitoring system based on web services can effectively take advantag...
2009-01-01
British Library Electronic Table of Contents (United Kingdom)
Mentougou District acts as a crucial component in the ecological buffer in western Beijing mountainous areas, Beijing, China. Using two Landsat MSS/TM images acquired on July 14, 1979 and July 23, 2005, the vegetation coverage of Mentougou District was calculated based on normalized difference vegetation index and spectral mixture analysis (NDVI-SMA) model. Its temporal and spatial changes were analyzed according to digital elevation model (DEM) image, social and economic data. The results showed that the vegetation coverage decreased from 76.4% in 1979 to 72.7% in 2005. Vegetation degradation was probably the result of human disturbance, such as outspreading of resident areas, and coal and stone mining activities, while vegetation restoration might be contributed by the combined effects o...
2009-01-01
Analysis of even harmonics generation in an isolated electric power system
British Library Electronic Table of Contents (United Kingdom)
Harmonics bred from loads are mainly odd order because the current waveforms have half-wave symmetry. Since the even harmonics are negligibly small, they generally are not measured in electric power systems. However, even harmonics were measured at a 500/275/154 kV substation in Hokuriku Electric Power Company after a transmission line fault was corrected. The even harmonics caused malfunctions of protective digital relays because the relays used 4th harmonics at the input filter as the automatic supervisory signal. This paper describes mechanisms of generation of the even harmonics by comparing the measured waveforms with the ATP-EMTP simulation results. Analysis of these results has clearly shown that there are three different mechanisms of generation of even harmonics. The first mechani...
2009-01-01
With the rapid growth of Information and Communication Technology, Electronic commerce is now acting as a new means of carrying out business transactions through electronic means such as Internet environment. To avoid the complexities associated with the digital cash and electronic cash, consumers and vendors are looking for credit card payments on the Internet as one possible time-tested alternative. This gave rise of the on-line payment processing using a third-party verification; which is not suitable for the developing countries in most of the cases because of the excessive costs associated with it for maintenance and establishment of an online third-party processor. As a remedy of this problem, in this paper, we have proposed a framework for easy security incorporation in credit card based electronic payment system without the use of an on-line third- party processor; which tends to be low cost and effective for the developing countries.
2006-01-01
A study of reconstruction algorithms and filters for an industrial X-ray tomography system
Energy Technology Data Exchange (ETDEWEB)
Computed tomography (CT) has been incorporated in an industrial Diode-Array Digital Radiography (DADR) system. An input data size of 512 pixel points x 400 projections yielded a 400x400 output image matrix. Reconstruction algorithms used are the filtered backprojection (FBP) and the direct Fourier reconstruction (DFR). Various filters were used in the FBP reconstruction process and their effects on image quality were evaluated. A spatial resolution of 100 {mu}m was measured with a block of plates and a minimum detectable feature size in the range of 10-100 {mu}m was measured using thin wires. Industrial specimens imaged have included ceramic samples, ball bearings and integrated circuits. A number of engineering problems have been solved, such as adjustment of the X-ray source, centering of the rotator spindle in the view field and beam-hardening corrections. (orig.).
1990-12-20
A new adaptive power system stabilizer using a Lyapunov design technique
Energy Technology Data Exchange (ETDEWEB)
A technique for designing an adaptive power system stabilizer is presented which improves the dynamic stability of power systems by effectively increasing the damping torque of the synchronous generator in the system. The proposed adaptive stabilizer is optimal in the sense of minimizing a specified performance condition. A characteristic feature of using a Lyapunov techniques is that it leads to stable adaptation loops. The dynamic responses following a step disturbance by digital simulations are obtained by means of three types of stabilizers: the conventional power system stabilizer, a frequency-response-based optimal adaptive stabilizer and the proposed Lyapunov stabilizer. Simulation results on a typical single-machine/infinite-bus system illustrate the superiority of the proposed technique. (author).
1990-04-01
A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements
Energy Technology Data Exchange (ETDEWEB)
A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).
1991-09-01
A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements
International Nuclear Information System (INIS)
A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).
A Study on the Photometric Redshifts of Faint Blue Galaxies in CDFS
British Library Electronic Table of Contents (United Kingdom)
From the COMBO-17 digital sky survey data, 1,231 faint blue galaxies with photometric redshifts of 0.1 2011-01-01
A Danish decision-support GIS tool for management of urban air quality and human exposures
Energy Technology Data Exchange (ETDEWEB)
A new prototype model system named AirGIS has been developed to support local authorities in air quality management for big Danish cities. The system is based on the Danish operational street pollution model (OSPM), technical and cadastral digital maps and Danish national administrative databases on buildings, cadastres and populations. It applies a geographic information system (GIS). AirGIS estimates ambient air pollution levels at high temporal and spatial resolutions. The model system enables mapping of traffic emissions, air quality levels and human exposures at residence addresses, at workplace addresses and in streets. Mapping and scenario results can be compared with air quality limits. Impact assessment of traffic air pollution abatement measures can also be carried out. (author)
2001-07-01
3-D depth migration via McClellan transformations
Energy Technology Data Exchange (ETDEWEB)
Three-dimensional seismic wavefields may be extrapolated in depth, one frequency at a time, by two-dimensional convolution with a circularly symmetric, frequency- and velocity-dependent filter. This depth extrapolation, performed for each frequency independently, lies at the heart of 3-D finite-difference depth migration. The computational efficiency of 3-D depth migration depends directly on the efficiency of this depth extrapolation. McClellan transformations provide an efficient method for both designing and implementing two-dimensional digital filters that have a particular form of symmetry, such as the circularly symmetric depth extrapolation filters used in 3-D depth migration. Given the coefficients of one-dimensional, frequency- and velocity-dependent filters used to accomplish 2-D depth migration, McClellan transformations lead to a simple and efficient algorithm for 3-D depth migration. 21 refs., 12 figs.
1990-01-01
Use of SPOT satellite imagery to obtain GIS input for oil spill models
Energy Technology Data Exchange (ETDEWEB)
Satellite imagery is a cost-effective tool for creating and updating basemaps of coastal zones, especially where existing maps and aerial photographs are unavailable, are out-of-date, or provide limited information. Reliable maps of coastal zones are particularly important for oil spill modelling programs. Color IR (multispectral) images with 20m x 20m ground resolution and black & white (panchromatic) images with 10m x 10m ground resolution of many coastlines around the globe have been acquired from 1986 to present by SPOT Image Corporation. We have digitally merged same-day SPOT panchromatic and multispectral imagery to provide maximum spatial resolution and permit excellent color differentiation of coastal zone features. This combination adequately discriminates individual features, including pipelines, offshore platforms, storage tanks, jetties, and shoreline type. The SPOT images were interpreted within a workstation environment and the coastline ...
1995-04-01
The clinical significance of Fuji computed radiography on lateral chest radiogram
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study was to clarify the benefits of digital lateral chest radiogram. In the basic study, the modulation transfer factor (MTF) and the wiener spectra (WS) of conventional screen film (CSF) and Fuji computed radiography (FCR) were measured. The visibility of the simulated nodules on FCR using 3 human bodies was subjectively compared with that on CSF by 13 observers. In the clinical study, the visibility of the normal structures on FCR was subjectively compared with that on CSF using 50 lateral chest radiograms by 10 observers. The diagnostic performance to detect pulmonary nodules on FCR was also compared with that on CSF using each 30 positive and negative cases by 8 observers. In the basic study, the MTF of FCR was superior to that of CSF, and the WS of FCR displayed in half size was superior to that of CSF. In all exposure conditions, the visibility of the nodules on FCR in the pulmonary apex was inferior to that on CSF, while FCR was superior ...
1995-02-01
The clinical significance of Fuji computed radiography on lateral chest radiogram
International Nuclear Information System (INIS)
The purpose of this study was to clarify the benefits of digital lateral chest radiogram. In the basic study, the modulation transfer factor (MTF) and the wiener spectra (WS) of conventional screen film (CSF) and Fuji computed radiography (FCR) were measured. The visibility of the simulated nodules on FCR using 3 human bodies was subjectively compared with that on CSF by 13 observers. In the clinical study, the visibility of the normal structures on FCR was subjectively compared with that on CSF using 50 lateral chest radiograms by 10 observers. The diagnostic performance to detect pulmonary nodules on FCR was also compared with that on CSF using each 30 positive and negative cases by 8 observers. In the basic study, the MTF of FCR was superior to that of CSF, and the WS of FCR displayed in half size was superior to that of CSF. In all exposure conditions, the visibility of the nodules on FCR in the pulmonary apex was inferior to that on CSF, while FCR was superior ...
1995-01-01
Energy Technology Data Exchange (ETDEWEB)
This paper bundles 40 contributions by the IceCube collaboration that were submitted to the 30th International Cosmic Ray Conference ICRC 2007. The articles cover studies on cosmic rays and atmospheric neutrinos, searches for non-localized, extraterrestrial {nu}{sub e}, {nu}{sub {mu}} and {nu}{sub {tau}} signals, scans for steady and intermittent neutrino point sources, searches for dark matter candidates, magnetic monopoles and other exotic particles, improvements in analysis techniques, as well as future detector extensions. The IceCube observatory will be finalized in 2011 to form a cubic-kilometer ice-Cherenkov detector at the location of the geographic South Pole. At the present state of construction, IceCube consists of 52 paired IceTop surface tanks and 22 IceCube strings with a total of 1426 Digital Optical Modules deployed at depths up to 2350 m. The observatory also integrates the 19 string AMANDA subdetector, that was completed in 2000 and extends ...
2007-11-02
The Advanced Photon Source injection timing system
Energy Technology Data Exchange (ETDEWEB)
The Advanced Photon Source consists of five accelerators. The injection timing system provides the signals required to cause a bunch emitted from the electron gun to navigate through intermediate accelerators to a specific bucket (1 out of 1296) within the storage ring. Two linacs and a positron accumulator ring operate at 60Hz while a booster synchrotron ramps and injects into the storage ring at 2Hz. The distributed, modular VME/VXI-based injection timing system is controlled by two EPICS-based input/output controllers (IOCs). Over 40 VME/VXI cards have been developed to implement the system. Card types range from 352MHz VXI timing modules to VME-based fiber optic fanouts and logic translators/drivers. All timing is distributed with fiber optics. Timing references are derived directly from machine low-level rf of 9.77MHz and 352MHz. The timing references provide triggers to programmable delay generators. Three grades of timing are provided. Precision timing is derived from commercial ...
1995-12-31
System control and data acquisition of the two new FWCD RF systems at DIII-D
Energy Technology Data Exchange (ETDEWEB)
The Fast Wave Current Drive (FWCD) system at DIII-D has increased its available radio frequency (RF) power capabilities with the addition of two new high power transmitters along with their associated transmission line systems. A Sun Sparc-10 workstation, functioning as the FWCD operator console, is being used to control transmitter operating parameters and transmission line tuning parameters, along with acquiring data and making data available for integration into the DIII-D data acquisition system. Labview, a graphical user interface application, is used to manage and control the above processes. This paper will discuss the three primary branches of the FWCD computer control system: transmitter control, transmission line tuning control, and FWCD data acquisition. The main control program developed uses VXI, GPIB, CAMAC, Serial, and Ethernet protocols to blend the three branches together into one cohesive system. The control of the transmitters utilizes VXI technology to communicate ...
1995-10-01
International Nuclear Information System (INIS)
Exploration for epithermal Au has been active lately in the Aegean Sea of the eastern Mediterranean Basin, both in the islands of the Quaternary arc and in those of the back-arc region. The purpose of this study was the structural mapping and analysis for a preliminary investigation of possible epithermal gold mineralization, using remotely sensed data and techniques, structural and field data, and geochemical information, for a specific area on the Island of Lesvos. Therefore, Landsat-TM and SPOT-Pan satellite images and the Digital Elevation Model (DEM) of the study area were processed digitally using spatial filtering techniques for the enhancement and recognition of the geologically significant lineaments, as well as algebraic operations with band ratios and Principal Component Analysis (PCA), for the identification of alteration zones. Statistical rose diagrams and a SCHMIDT projection Stereo Net were generated from the lineament maps and ...
2000-12-01
International Nuclear Information System (INIS)
Our purpose in this work was to develop an automatic boundary detection method for mammographic masses and to rigorously test this method via statistical analysis. The segmentation method utilized a steepest change analysis technique for determining the mass boundaries based on a composed probability density cost function. Previous investigators have shown that this function can be utilized to determine the border of the mass body. We have further analyzed this method and have discovered that the steepest changes in this function can produce mass delineations that include extended projections. The method was tested on 124 digitized mammograms selected from the University of South Florida's Digital Database for Screening Mammography (DDSM). The segmentation results were validated using overlap, accuracy, sensitivity, and specificity statistics, where the gold standards were manual traces provided by two expert radiologists. We have concluded ...
2004-10-01
Seismological study at the Kyungsang basin 2
Energy Technology Data Exchange (ETDEWEB)
The end of 1994, five seismic observation stations were constructed with digital seismograph and 3-component seismometers. In this study, the epicentral distribution around the Kyungsang basin was obtained from one-year earthquake data (1994/12 - 1995/11) and compared with the annual earthquake report of KMA (Korea Meteorological Agency). The geological structure at the middle of the Ulsan fault was also investigated by the electrical resistivity method. The epicenters show high concentration at the Wolsung area. They show a linear alignment and their depths tend to be deeper as they approach to the coast line of the East Sea. These imply that they are probably correlated together. Another remarkable feature on land is the linear epicentral distribution along Jiri mountain to the Kimcheon and Sangju. This line is well coincident with newly recognized lineament. The other is the epicentral distribution at the Straits of Korea and East Sea. Even though some far ...
1995-12-01
Real-time neutron radiography; Radiografia com neutrons em tempo-real
Energy Technology Data Exchange (ETDEWEB)
The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the {gamma}-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10{sup 6}n/cm{sup 2}s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/{gamma} ratio {approx} 10{sup 6}n/cm{sup 2}mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame grabber and a computer. The device composed ...
2000-07-01
International Nuclear Information System (INIS)
The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the #gamma#-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10"6n/cm"2s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/#gamma# ratio #approx# 10"6n/cm"2mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame grabber and a computer. The device composed by the scintillator ...
2000-01-01
Real-time neutron coded aperture imaging: A technique for nondestructive three-dimensional imaging
Energy Technology Data Exchange (ETDEWEB)
Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to Computed Tomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas Computed Tomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only a small fraction of the neutrons incident on the object are scattered to the neutron camera, a new neutron beamport facility, with a larger neutron flux (7.3 x 10[sup 7] n/cm[sup 2]/s) than the previous ...
1992-01-01
Real-time monitoring of dosimetry and image quality during digital radiology examinations
International Nuclear Information System (INIS)
Objective: To explore the feasibility of real-time monitoring exposure dose and image quality by using the data stored in the DICOM image archive of direct digital radiography system. Methods: Model TO. 16 was exposed, the current increased gradually from 0.5 to 125 mAs. The displayed number of model A( diameter 11.1 mm), D (diameter 4.0 mm) and J( diameter 0.7 mm) were recorded, and the detect factors (H_T) was also calculated. Images were sent to workstation before the end of DR examination. An automatic procedure was implemented to extract dose data and exposure parameters from the DICOM header file. Maximum, minimum and 3rd quartile values were preinstalled. Mean values exceeding the threshold trigger alarm signal to guide radiologist to explore the cause. Results: When the current of point A was less than 10 mAs and the current of point D and J were less than 16 mAs, the detect factor (H_T) increased with the rise of current. While point A located within ...
2009-12-01
Energy Technology Data Exchange (ETDEWEB)
Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and displayed four images as a subsidiary diagnosis. The upper two images were displayed ...
1989-08-01
Pulmonary nodule detection of chest phantom with CRT images
International Nuclear Information System (INIS)
Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and displayed four images as a subsidiary diagnosis. The upper two images were displayed ...
1989-01-01
Energy Technology Data Exchange (ETDEWEB)
Airbag pressure vessels for the north-American market mainly are made by forging and by the use of steel alloys. In Europe aluminum alloys are common and the manufacturing process is extrusion of circular blanks - made from cold rolled plates - in a form applying a 100 t press at room temperature. Then by heat treatment the strength/hardness of the material is properly adjusted and after that the pressure vessel parts have to be continuously inspected with an inspection and handling cycle time of 3 s. Inspection of the axis-symmetric parts is asked for surface breaking extrusion defects as well as for surface parallel delaminations in the bulk volume. Furthermore, the material strength is a quality characteristic that has to be nondestructively registered and documented. The inspection is performed by eddy current probes and an EMAT, of which the eddy current impedance measurements are used for surface breaking extrusion defect detection and sizing (single frequency technique with ...
1999-07-01
DEFF Research Database (Denmark)
Promoted as the first academic conference to be held completely in graphical cyberspace, Avatars 98 took place in November 1998. The virtual conference site was built and inhabited using software that supports multi-party presence over the Internet in a simulated, navigable environment. During the conference, avatar-embodied speakers using text chat performed to virtual audiences, 'webcams' (re)broadcast live video images of CNN and other remote sites, and a 'webcast' sent audiovisual representations captured by video camera of certain key participants in their physical locations. Such a novel and spectacular multi-media event raises many questions. How do we conceive of the recent developments in media technology and social computing that are impacting on what we have traditionally called 'the mass media'? How is interaction and talk mediated and adapted to new media genres? And how do participants construct and maintain senseful talk in a sometimes bewildering, 'inhabited', ...
International Nuclear Information System (INIS)
To evaluate the diagnostic performance of commercially available CRT monitors used in a teleradiology system by determining the rate of detection of simulated lung nodules. Three types of CRT monitors were tested in the observation study. They had matrix sizes of 1024 x 768 (16 inches, color), 1024 x 768 (20 inches, color) and 1600 x 1125 (24 inches, black and white). Twenty chest radiographs were obtained by Fuji computed radiography (FCR) of an anthropomorphic chest phantom with ten simulated nodules on its surface. These FCR films were digitized by a film digitizer with 125 DPI (1024 x 1024 matrix sizes) and 12 bit gray scales, and the image data were transferred from Shinshu University Hospital to other hospitals where interpretation was carried out by the radiologists. Ten radiologists of three hospitals were asked to interpret independently both the original FCR films and the images shown on the CRT monitors and to indicate the presence ...
International Nuclear Information System (INIS)
The document represents a specific type of discussion of existing methodologies for the creation and application of probabilistic safety assessment (PSA) in light of the EUR document summarizing requirements placed by Western European NPP operators on the future design of nuclear power plants. A partial goal of this discussion consists in mapping, from the PSA point of view, those selected design, operational and/or safety factors of future NPPs that may be entirely new or, at least, newly addressed. Therefore, the terms of reference for this stage were formulated as follows: Assess current level of knowledge and procedures in the analysis of factors and phenomena with a dominant influence upon operational safety of new generation reactors, especially in the following areas: (1) Phenomenology of failure types and mechanisms and reliability of conventional passive safety system components; (2) Phenomenology of failure types and mechanisms and reliability of non-conventional passive ...
Introducing DeBRa: a detailed breast model for radiological studies
Energy Technology Data Exchange (ETDEWEB)
Currently, x-ray mammography is the method of choice in breast cancer screening programmes. As the mammography technology moves from 2D imaging modalities to 3D, conventional computational phantoms do not have sufficient detail to support the studies of these advanced imaging systems. Studies of these 3D imaging systems call for a realistic and sophisticated computational model of the breast. DeBRa (Detailed Breast model for Radiological studies) is the most advanced, detailed, 3D computational model of the breast developed recently for breast imaging studies. A DeBRa phantom can be constructed to model a compressed breast, as in film/screen, digital mammography and digital breast tomosynthesis studies, or a non-compressed breast as in positron emission mammography and breast CT studies. Both the cranial-caudal and mediolateral oblique views can be modelled. The anatomical details inside the phantom include the lactiferous duct system, the ...
2009-07-21
Energy Technology Data Exchange (ETDEWEB)
The paper reports on the results of a study of the synthesis conditions effects on magnetic and transport properties of nanosized layers of high-T{sub c} diluted magnetic semiconductors (DMS), such as Ge:Mn, Si:Mn and Si:Fe, fabricated by laser-plasma deposition over a wide range of the growth temperature, T{sub g}=(20-550) deg. C on single-crystal GaAs or Al{sub 2}O{sub 3} substrates. Ferromagnetism of the layers was detected by measurement data of the magneto-optical Kerr effect, anomalous Hall effect, negative magnetoresistance and ferromagnetic resonance (FMR) at 5-500 K. The optimum growth temperature, T{sub g}, for Si:Mn/GaAs layers with T{sub c}{approx}400 K is shown to be about 400 deg. C. The Si:Mn/Al{sub 2}O{sub 3} layers with 35% of Mn have the metal-type of conductivity with manifestation of magnetization up to room temperature. Different types of uniformly doped structures and digital alloys have been investigated. In contrast to GaSb:Mn films, ...
2009-04-15
Global positioning automatic vehicle location system
Energy Technology Data Exchange (ETDEWEB)
Los Alamos National Laboratory (LANL) is a unique facility covering over 43 square miles. The Emergency Management and Response Office (EM&R) is required to respond, provide Incident Command (IC), and coordination for all Laboratory emergencies. This requires IC`s and support staff to respond to the actual scene of the incident. Since the IC is under numerous constraints and stress, the office wanted the capability of locating the EM&R vehicles on an electronic map. An automated vehicle location (AVL) system was required for the additional safety of the emergency response personal. The requirements for the AVL system include total automatic tracking and low cost. After careful consideration, it was determined that the most efficient and cost effective system would be based on packet radio technology as the transmission media. The location is determined by the Department of Defense Global Positioning System (GPS). The system that was designed and constructed required four ...
1997-03-01
Fuji computed radiography (FCR) for the diagnosis of spinal disorders
Energy Technology Data Exchange (ETDEWEB)
Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the ...
1987-04-01
Field investigation of radio network usage at the dismounted infantry section level
The Soldier Information Requirements Technology Demonstration (SIREQ TD) project is an experimentation program to identify technologies that significantly enhance the performance of our future soldiers. One of the study series involved a 2 x 2 factorial comparison of the benefits of digital maps over paper maps, and the use of radios vs. no radios. Thirty-two Canadian regular force infantry soldiers performed force-on-force tactical assault missions in wooded terrain, with each soldier participating in all four test conditions. The radios were configured to operate in 4 subnets: 1 channel for each of the 2 Assault Groups (4 soldiers on a channel); a Section Commander/2IC channel; and an all-users channel. Note that in the no-radio conditions soldiers still operated the press-to-talk switch to allow recording of communications, but the speaker volume was set to zero. All communications were date/time stamped, identified as to the user and channel, and the audio was ...
2006-06-01
Computer vision algorithms in DNA ploidy image analysis
The high incidence and mortality rates of prostate cancer have stimulated research for prevention, early diagnosis and appropriate treatment. DNA ploidy status of tumour cells is an important parameter with diagnostic and prognostic significance. In the current study, DNA ploidy analysis was performed using image cytometry technique and digital image processing and analysis. Tissue samples from prostate patients were stained using the Feulgen method. Images were acquired using a digital imaging microscopy system consisting of an Olympus BX-50 microscope equipped with a color CCD camera. Segmentation of such images is not a trivial problem because of the uneven background, intensity variations within the nuclei and cell clustering. In this study specific algorithms were developed in Matlab based on the most prominent image segmentation approaches that emanate from the field of Mathematical Morphology, focusing on region-based watershed ...
2006-03-01
ARDEC transition armature study. Progress report No. 3, October 1--November 30, 1991
Energy Technology Data Exchange (ETDEWEB)
This third report covers the period October 1 to November 30, 1991. During this period the authors: (1) fabricated a test fixture for studying hybrid armature brush behavior, (2) reactivated a 140kJ, 1MA capacitor bank, (3) reactivated 25 channels digital data acquisition and reduction system and (4) concluded the use of a DNA funded railgun would serve as the most expedient means to acquire a railgun test bed. Fabrication of a plasma brush test fixture for studying the formation, evolution and stability of plasma brushes was completed. The fixture will serve to study plasma brush parameters, such as brush length and voltage drop, as a function of initial solid foil mass, gap size and current concentration. A 4OkV, 168{mu}f, 140kJ capacitor bank capable of providing more than 1MA of current was reactivated. (The LLNL bank had been developed for opening switch research which was successfully completed.) The bank will be used to power the test fixture with 10{mu}s, ...
1992-05-13
A wavelet-fuzzy combined approach for classification and location of transmission line faults
Energy Technology Data Exchange (ETDEWEB)
This paper presents a real-time wavelet-Fuzzy combined approach for digital relaying. The algorithm for fault classification employs wavelet multi resolution analysis (MRA) to overcome the difficulties associated with conventional voltage and current based measurements due to effect of factors such as fault inception angle, fault impedance and fault distance. The proposed algorithm for fault location, different from conventional algorithms that are based on deterministic computations on a well-defined model to be protected, employs wavelet transform together with fuzzy logic. The wavelet transform captures the dynamic characteristics of the non-stationary transient fault signals using wavelet MRA coefficients. The fuzzy logic is employed to incorporate expert evaluation through fuzzy inference system (FIS) so as to extract important features from wavelet MRA coefficients for obtaining coherent conclusions regarding fault location. Computer simulations using MATLAB ...
2007-11-15
A comprehensive understanding of the efficacy of N-Ring hardening methodologies in SiGe HBTs
International Nuclear Information System (INIS)
We investigate the efficacy of mitigating radiation-based single event effects (SEE) within circuits incorporating SiGe heterojunction bipolar transistors (HBTs) built with an N-Ring, a transistor-level layout-based radiation hardened by design (RHBD) technique. Previous work of single-device ion-beam induced charge collection (IBICC) studies has demonstrated significant reductions in peak collector charge collection and sensitive area for charge collection; however, few circuit studies using this technique have been performed. Transient studies performed with Sandia National Laboratory's (SNL) 36 MeV 16O microbeam on voltage references built with N-Ring SiGe HBTs have shown mixed results, with reductions in the number of large voltage disruptions in addition to new sensitive areas of low-level output voltage disturbances. Similar discrepancies between device-level IBICC results and circuit measurements are found for the case of digital shift registers implemented ...
2010-07-19
Energy Technology Data Exchange (ETDEWEB)
NO{sub x} compounds, specifically NO and NO{sub 2}, are pollutants and potent greenhouse gases. Compact and inexpensive NO{sub x} sensors are necessary in the next generation of diesel (CIDI) automobiles to meet government emission requirements and enable the more rapid introduction of more efficient, higher fuel economy CIDI vehicles. Because the need for a NO{sub x} sensor is recent and the performance requirements are extremely challenging, most are still in the development phase. Currently, there is only one type of NO{sub x} sensor that is sold commercially, and it seems unlikely to meet more stringent future emission requirements. Automotive exhaust sensor development has focused on solid-state electrochemical technology, which has proven to be robust for in-situ operation in harsh, high-temperature environments (e.g., the oxygen stoichiometric sensor). Solid-state sensors typically rely on yttria-stabilized zirconia (YSZ) as the oxygen-ion conducting electrolyte and then target ...
2010-11-01
[Validity of the tympanic infrared thermometer in geriatric inpatients].
The purpose of this study was to assess the agreement between rectal temperature and infrared emission detection (IRED). The specificity and sensitivity, the positive predictive value and the negative predictive value were calculated. It was a prospective, observational and unblinded study. Thermoscan-pro-1 was used to collect pairs of data in 41 patients, all hospitalised on an acute geriatric ward during a 4-month period. 41% of the patients were febrile. The 'bias' between rectal and tympanic measurement (left ear) was -0.64 degree C (d) and the standard deviation 0.58 degree C (s). The '95% Confidence Interval' for the bias was -0.82 degree C and -0.46 degree C. The '95% limits of agreement' between the rectal measurement and the tympanic measurement (left ear) was -1.78 degrees C and 0.50 degree C. Regression analysis taught us that bias was increasing with increasing temperature. If we take into account one measurement with the IRED ear thermometry, the sensitivity was 41%, the ...
2001-10-01
Wetlands of Argonne National Laboratory-East DuPage County, Illinois
Energy Technology Data Exchange (ETDEWEB)
Jurisdictional wetlands of the Argonne National Laboratory-East (ANL-E) site in DuPage County, Illinois, were delineated in the summer and autumn of 1993 in accordance with the 1987 US Army Corps of Engineers methodology. Potential wetland sites with an area greater than 500 m{sup 2} (0.05 ha [0.124 acre]) were identified for delineation on the basis of aerial photographs, the DuPage County soil survey, and reconnaissance-level field studies. To qualify as a jurisdictional wetland, an area had to support a predominance of hydrophytic vegetation as well as have hydric soil and wetland hydrology. Thirty-five individual jurisdictional wetlands were delineated at ANL-E, totaling 180,604 m{sup 2} (18.1 ha [44.6 acres]). These wetlands were digitized onto the ANL-E site map for use in project planning. Characteristics of each wetland are presented -- including size, dominant plant species and their indicator status, hydrologic characteristics (including water source), ...
1994-03-01
West Siberian basin hydrogeology - regional framework for contaminant migration from injected wastes
Energy Technology Data Exchange (ETDEWEB)
Nuclear fuel cycle activities of the former Soviet Union (FSU) have resulted in massive contamination of the environment in western Siberia. We are developing three-dimensional numerical models of the hydrogeology and potential contaminant migration in the West Siberian Basin. Our long-term goal at Pacific Northwest Laboratory is to help determine future environmental and human impacts given the releases that have occurred to date and the current waste management practices. In FY 1993, our objectives were to (1) refine and implement the hydrogeologic conceptual models of the regional hydrogeology of western Siberia developed in FY 1992 and develop the detailed, spatially registered digital geologic and hydrologic databases to test them, (2) calibrate the computer implementation of the conceptual models developed in FY 1992, and (3) develop general geologic and hydrologic information and preliminary hydrogeologic conceptual models relevant to the more detailed ...
1994-05-01
Undoing forgetfulness: Chiasmus of Poetical Mind - a Cultural Paradigm of Archetypal Imagination
DEFF Research Database (Denmark)
Abstract This paper tries to investigate the problem of memory through one of its most intriguing patterns - chiasmus - reflected in old poetry, sacred texts, philosophy and theology, visual arts, as well as biology. It aims to search for some provisory explanation of why man was able once to acquire such excellence in memorizing internally thousands of lines of poetry, whereas now memory is expelled outside the human body and mind in a mere digital file. Contrasting the so-called "wish-dream for immortality" of the contemporary post-human body, this paper takes another path and looks into some old cosmologies and visions in which chiasmus constantly emerged as an enduring cultural paradigm with ontological relevance. Spanning from Plato to Christian theology, up to the contemporary Neo-Platonism of archetypal psychology, this paper hopes to put forth, if not a theory, at least a vision about man and cosmos, cosmos and man, a chiastic epiphany in which the body and ...
2005-01-01
Three-dimensional power system stabilizer
Energy Technology Data Exchange (ETDEWEB)
Power system stabilizers (PSSs) are used to enhance damping of power system oscillations through excitation control of synchronous generator. The objective of the PSS is to generate a stabilizing signal, which produces a damping torque component on the generator shaft. Conventional PSSs are designed with the phase compensation technique in the frequency domain and include the lead-lag blocks whose parameters are determined according to a linearized power system model. The performance of conventional PSSs (CPSSs) depends upon the generator operating point and the system parameters, but a reasonable level of robustness can be achieved depending on the tuning method. This paper presents a new three-dimensional PSS (3D PSS), which uses rotor speed deviation, rotor acceleration and load angle deviation as input signals. The 3D PSS attempts to return the generator to the state-space origin, based on the generator's trajectory in state-space and the achievement of torque equilibrium. ...
2010-07-15
The vital importance of GIS : a workshop in project siting and development
Energy Technology Data Exchange (ETDEWEB)
Geographic information system (GIS) technology is now being used by wind energy developers who are required to consider and accommodate a wide variety of environmental and social considerations. This poster presentation discussed some of the new features available in current GIS technologies. High resolution imagery from satellites is being used to verify the accuracy of collected spatial data, as well as to investigate potential locations for meteorological towers, turbine sites, and roads. Slopes are easily calculated using GIS software tools, and digital elevation data can be used with high resolution aerial photography to determine routes for new roads and to establish available sites for crane pads. The GIS tools allow developers to consider protected ecological areas, wetlands and forests, and gives them the ability to better report project development considerations at public consultations. Wind resource grid outputs can also be projected using GIS software. ...
2010-07-01
The relationship between hyperactivity and neuropsychological test performance at different age levels was examined. It was found that for young children (6 to 8 years of age, n = 90), there was no significant association between hyperactivity/attentional problems (as measured by the Hyperactivity scale of the Child Behavior Checklist) and performance on neuropsychological tasks thought to contain an attentional component (WISC-R Coding, Arithmetic, and Digit Span; WRAT Arithmetic; and the Benton Visual Retention Test). However, for older children (9 to 12 years of age, n = 92), there were significant and large negative correlations between CBC Hyperactivity scores and Coding, WRAT Arithmetic, and Benton VRT scores. Multiple regression analyses supported the above results (for Coding and WRAT Arithmetic), indicating that hyperactivity/inattention has a particularly deleterious effect on test performance (relative to same-age peers) as age increases. PMID:3361033
1988-02-01
The Outer Disks of Early-Type Galaxies. I. Surface-Brightness Profiles of Barred Galaxies
We present a study of 66 barred, early-type (S0-Sb) disk galaxies, focused on the disk surface brightness profile outside the bar region and the nature of Freeman Type I and II profiles, their origins, and their possible relation to disk truncations. This paper discusses the data and their reduction, outlines our classification system, and presents $R$-band profiles and classifications for all galaxies in the sample. The profiles are derived from a variety of different sources, including the Sloan Digital Sky Survey (Data Release 5). For about half of the galaxies, we have profiles derived from more than one telescope; this allows us to check the stability and repeatability of our profile extraction and classification. The vast majority of the profiles are reliable down to levels of mu_R ~ 27 mag arcsec^-2; in exceptional cases, we can trace profiles down to mu_R > 28. We can typically follow disk profiles out to at least 1.5 times the traditional optical radius ...
2007-01-01
International Nuclear Information System (INIS)
Studies on the multivariate autoregressive (MAR) analysis are carried out for the choice of the parameters for modelling the data obtained from various sensors optimally. Accordingly, the roles of the parameters on the analysis results are identified and the related ambiguities are reduced. Experimental investigations are carried out by means of synthesized reactor noise-like data obtained from a digital simulator providing simulated stochastic signals of an operating nuclear reactor so that the simulator constitutes a favourable tool for the present studies aimed. As the system is well defined with its known structure, precise comparison of the MAR analysis results with the true values is performed. With the help of the information gained through the studies carried out, conditions to be taken care of for optimal signal processing in MAR modelling are determined. Although the parameters involved are related among themselves and they have to be given different ...
1987-10-01
Steganography using wavelet compressed images
Internet bandwidth is in high demand, and one way that web sites lower the amount of bandwidth they use is by compressing their site's images. This lowers the amount of bandwidth used, and makes the site load much faster. There are of course many other useful applications for compressed images. Bit Plane Complexity Segmentation (BPCS) digital picture steganography is a technique to hide data inside an image file. BPCS achieves high embedding rates with low distortion based on the theory that noise-like regions in a bit-plane can be replaced with noise-like secret data without discernible loss in image quality. This is possible because the human eye, while very good at distinguishing anomalies in areas of homogenous texture, is bad at distinguishing anomalies in visually complex areas. However, BPCS is not a robust embedding scheme, and any lossy compression usually destroys the data. Wavelet image compression using the Discreet Wavelet Transform (DWT) is the basis ...
2001-08-01
Photon dosimetry using plastic scintillators in pulsed radiation fields
Energy Technology Data Exchange (ETDEWEB)
Simulations and experiments have been carried out to explore using a plastic scintillator as a dosimetry probe in the vicinity of a pulsed bremsstrahlung source in the range 4 to 20 MeV. Taking advantage of the tissue-equivalent properties of this detector in conjunction with the use of a fast digital signal processor near real-time dosimetry was shown to be possible. The importance of accounting for a broad energy electron beam in bremsstrahlung production, and photon scattering and build-up, in correctly interpreting dosimetry results at long stand-off distances is highlighted by comparing real world experiments with ideal geometry simulations. Close agreement was found between absorbed energy calculations based upon spectroscopic techniques and calculations based upon signal integration, showing a ratio between 10 MeV absorbed dose to 12 MeV absorbed dose of 0.66 at a distance of 91.4 m from the accelerator. This is compared with an idealized model simulation ...
2007-04-01
Optimisation of imaging technique used in direct digital radiography
Energy Technology Data Exchange (ETDEWEB)
The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion from being reached. The fact that all images were of diagnostic quality, however, suggested that the use of the anti-scatter grid was unnecessary. ...
2006-09-15
Optimisation of imaging technique used in direct digital radiography
International Nuclear Information System (INIS)
The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion from being reached. The fact that all images were of diagnostic quality, however, suggested that the use of the anti-scatter grid was unnecessary. ...
2006-09-01
Morphological classification and structural parameters for early-type galaxies in the Coma cluster
We present the results of an isophotal shape analysis of three samples of galaxies in the Coma cluster. Quantitative morphology, together with structural and photometric parameters, is given for each galaxy. Special emphasis has been placed on the detailed classification of early-type galaxies. The three samples are: i) a sample of 97 early-type galaxies brighter than m_B = 17.00 falling within one degree from the center of the Coma cluster; these galaxies were observed with CCD cameras, mostly in good to excellent resolution conditions; ii) a magnitude complete sample of 107 galaxies of all morphological types down to m_B = 17.00 falling in a circular region of 50 arcmin diameter, slightly offcentered to the North-West of the cluster center; the images for this and the next sample come from digitized photographic plates; iii) a complete comparison sample of 26 galaxies of all morphological types down to m_R = 16.05 (or m_B \\simeq 17.5), also in a region of 50 ...
1995-01-01
Modeling the internal combustion engine
Energy Technology Data Exchange (ETDEWEB)
A flexible and computationally economical model of the internal combustion engine was developed for use on large digital computer systems. It is based on a system of ordinary differential equations for cylinder-averaged properties. The computer program is capable of multicycle calculations, with some parameters varying from cycle to cycle, and has restart capabilities. It can accommodate a broad spectrum of reactants, permits changes in physical properties, and offers a wide selection of alternative modeling functions without any reprogramming. It readily adapts to the amount of information available in a particular case because the model is in fact a hierarchy of five models. The models range from a simple model requiring only thermodynamic properties to a complex model demanding full combustion kinetics, transport properties, and poppet valve flow characteristics. Among its many features the model includes heat transfer, valve timing, supercharging, motoring, ...
1985-03-01
Microprocessor-controlled anodic stripping voltammeter for trace metal analysis in tap water
Energy Technology Data Exchange (ETDEWEB)
The construction and use of a portable, microprocessor controlled anodic stripping voltameter for on-site simultaneous metal analysis of copper, lead and cadmium in tap water is discussed. The instrumental system is comprised of a programmable controller which permits keying in analytical parameters such as sparge time and plating time: a rotating cell for efficient oxygen removal and amalgam formation; and, data handling via a minicomputer or analog pen recorder. Plating and stripping potentials are controlled by a digital potentiostat; stripping is done using a staircase waveform with measurement of the current after a one msec delay. In this way charging current effects are minimized. Results of tap water analysis showed 3 +- 1 ..mu..g/L lead, 22 +- 0.3 ..mu..g/L copper, and less than 0.2 ..mu..g/L cadmium for a Berkeley, California tap water, and 1-1000 ..mu..g/L Cu, 1 -2 ..mu..g/L Pb for ten samples of Seattle, Washington tap water. Recommendations are given ...
1984-06-01
Microprocessor system controlling gas-carburizing process
Energy Technology Data Exchange (ETDEWEB)
This report introduces a microprocessor system composed of a Z-80 single-board computer controlling a gas-carburizing process. The system has 7 analogical input and output signals 24 switch signal-input and 12 switch signal-output signals, which are applicable for temperature, carbon potential, and mechanical-movement control of multipurpose sealed furnaces, or for mutiple-zone temperature, carbon potential, and mechanical-movement control of continuous gas carburizing furnaces; or for distributed control of pit-type carburizing furnaces. The setpoints of variables, such as treating time, temperature, carbon potential of carburizing period, carbon potential of diffusion period, depth of carburizing layer, P.I.D. etc., are entered by keyboard and stored into memories, and actual values are displayed by digital tubes. Furthermore, the fault of thermocouple, oxygen probe, or infrared CO/sub 2/ analyzer; carbon potential, or temperature exceeding the setting value; ...
1986-01-01
Medical image transmission via communication satellite. Evaluation of bone scintigraphy
International Nuclear Information System (INIS)
As compared with terrestrial circuits, the communication satellite possesses superior characteristics such as wide area coverage, broadcasting, high capacity, and robustness to disasters. Utilizing the narrow band channel (64 kbps) of the geostationary satellite JCSAT 1 located at the altitude of 36,000 km above the equator, the authors investigated satellite-relayed medical imagings by video signals, with bone scintigraphy as a model. Each bone scintigraphy was taken by a handy-video camera, digitalized and transmitted from faculty of technology located at 25 kilometers apart from our department. Clear bone scintigraphy was obtained via satellite, as seen on the view box. Eight nuclear physicians evaluated 20 cases of bone scintigraphy. ROC (Receiver Operating Characteristic) analysis was performed between the scintigraphies on view box and via satellite by the rating method. The area under the ROC curve was 91.6#+-#2.6% via satellite, and 93.2#+-#2.4% on the view ...
Localization explore of electrical and I and C equipments in Daya Bay Nuclear Power Station
International Nuclear Information System (INIS)
The supply of electronic instrumentation and controlling (I and C) equipments in Daya Bay Nuclear Power Station depends on importation up to now, however, reliable supply of spare parts is presently threatened by many factors. Consequently, Daya Bay Nuclear Power Station tries to localize these equipments. According to a survey, China has possessed the ability to undertake the research, development and production of the I and C system in nuclear power independently. We propose that localization should firstly starts with the production of replacement board and parts for analogical I and C system, gradually leads to the substitution of system cabinet units, and finally realize the independent research, development and production of advanced digital main control system. A series of prominent problems of producing nuclear grade I and C equipments are focused on the designing, manufacturing, testing and reliability evaluation. In this paper, technical procedures, ...
2007-10-01
Limitations of traveling wave relaying for overhead EHV transmission lines
Energy Technology Data Exchange (ETDEWEB)
Limitations of traveling wave relaying schemes for protection of overhead extra-high voltage transmission lines are investigated. A method of analysis of traveling wave phenomena for three phase transmission lines is developed in which the interdependent phase voltages and currents are decoupled into their modal counterparts, which are approximately independent. A time domain digital simulation program is used to solve the modal transmission line equations to obtain the fault induced traveling waves detected at the relay location. The frequency dependence of the aerial modes is ignored but their losses are included. A lumped element analysis method, originally developed for transient analysis of lossy coaxial cables, is adapted here to obtain approximate solution for the fault induced traveling waves of the ground mode. Excellent agreement is found between the results obtained by this method and frequency domain methods. This time-domain method offers more ...
1986-01-01
Latest Observational Constraints on Cardassian Models
Constraints on the original Cardassian model and the modified polytropic Cardassian model are examined from the latest derived 397 Type Ia supernova (SNe Ia) data, the size of baryonic acoustic oscillation peak from the Sloan Digital Sky Survey (SDSS), the position of first acoustic peak of the Cosmic Microwave Background radiation (CMB) from the five years Wilkinson Microwave Anisotropy Probe (WMAP), the x-ray gas mass fractions in clusters of galaxies, and the observational H(z) data. In the original Cardassian model with these combined data set, we find $\\Omega_{m0}=0.271^{+0.014}_{-0.014}, n=0.035^{+0.049}_{-0.049}$ at $1 \\sigma$ confidence level. And in the modified polytropic Cardassian model, we find that $\\Omega_{m0}=0.271^{+0.014}_{-0.015}$, $n=-0.091^{+0.331}_{-1.908}$ and $\\beta=0.824^{+0.750}_{-0.622}$ within $1\\sigma$ confidence level. According to these observations, the acceleration of the universe begins at $z_T=0.55^{+0.05}_{-0.05} (1\\sigma)$ ...
2009-01-01
Improvement of FCR-linear tomography using digital image processing
Energy Technology Data Exchange (ETDEWEB)
In order to improve the image quality of linear tomography performed with the Fuji Computed Radiography (FCR) system, we have examined one-dimensional unsharp mask filtering to reduce blur formed in the direction of tomographic swing. We determined a mask size and a weighting factor of the image processing suitable to obtain a quality tomogram. The mask size of 41 x 1 pixels for a 14 x 14'' imaging plate, which modifies the original image date and results in demonstrating a peak frequency at 0.2 cycles/mm for spatial frequency spectrum, is superior in showing fine vessel structures and morphological features of pathology in the lung fields. An additional spatial frequency filtration in the direction perpendicular to the tomographic movement reduces the blur and clearly demonstrates object contours running parallel to the tube movement. However, the additional filtration increases the appearance of noise on the processed image and offsets the advantages of the ...
1994-02-01
Galaxy Cluster Environments of Radio Sources
Using the Sloan Digital Sky Survey (SDSS) and the FIRST (Faint Images of the Radio Sky at Twenty Centimeters) catalogs, we examined the optical environments around double-lobed radio sources. Previous studies have shown that multi-component radio sources exhibiting some degree of bending between components are likely to be found in galaxy clusters. Often this radio emission is associated with a cD-type galaxy at the center of a cluster. We cross-correlated the SDSS with the FIRST catalog and measured the richness of the cluster environments surrounding both bent and straight multi-component sources. This led to the discovery and classification of a large number of galaxy clusters out to a redshift of z ~ 0.5. We divided our sample into smaller subgroups based on their optical and radio properties. We find that FR I radio sources are more likely to be found in galaxy clusters than FR II sources. Further, we find that bent radio sources are more often found in galaxy ...
2010-01-01
Electric field measurement on time domain generated by corona on insulators on distribution systems
Energy Technology Data Exchange (ETDEWEB)
Radio interference and TV interference are being a problem in urban and rural areas. This interference is generated by high voltage transmission lines as well as distribution lines. The radio noise can be produced by polluted or damaged insulators, and by metal parts of the distribution lines. The corona effect on the surface of the dielectric material produces high frequency electromagnetic fields during the ionization and during the recombination period. Fields of different intensity are produced by positive voltage and negative voltage. The insulator flashover (leaking current) also produces electromagnetic fields. A new technique to measure these fields was developed. This technique measures the radiated fields on time domain and on frequency domain. This permits us to characterize the radiated field and thus identify the type of the source. Several measurements were done varying the type of the RF generator, i.e., new insulator and broken insulator. A ...
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was evaluated by 19 radiologists, using ROC curve analysis. FCR and CoR revealed the similar diagnostic ...
1989-02-01
International Nuclear Information System (INIS)
Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was evaluated by 19 radiologists, using ROC curve analysis. FCR and CoR revealed the similar diagnostic ...
1989-01-01
Detection of Second-Layer Corrosion in Aging Aircraft Fuselage
International Nuclear Information System (INIS)
A Digital X-ray imaging system using Compton backscattering has been developed to obtain a cross-sectional profile and mass loss of corroded lap-splices of aging aircraft from density variation. A slit-type camera was designed to focus on a small scattering volume inside the material, from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the lap-joint is scanned by moving the scattering volume through the thickness direction of the specimen. The mass loss of each layer has been estimated from a Compton backscatter A-scan to obtain the thickness of each layer including the aluminum sheet, the corrosion layer and the sealant. Quantitative information such as location and width of planar corrosion in the lap splices of fuselages is obtained by deconvolution using a nonlinear least-square error minimization method(BFGS method): A simple reconstruction model is also ...
2006-12-01
Computational AstroStatistics Fast and Efficient Tools for Analysing Huge Astronomical Data Sources
I present here a review of past and present multi-disciplinary research of the Pittsburgh Computational AstroStatistics (PiCA) group. This group is dedicated to developing fast and efficient statistical algorithms for analysing huge astronomical data sources. I begin with a short review of multi-resolutional kd-trees which are the building blocks for many of our algorithms. For example, quick range queries and fast n-point correlation functions. I will present new results from the use of Mixture Models (Connolly et al. 2000) in density estimation of multi-color data from the Sloan Digital Sky Survey (SDSS). Specifically, the selection of quasars and the automated identification of X-ray sources. I will also present a brief overview of the False Discovery Rate (FDR) procedure (Miller et al. 2001a) and show how it has been used in the detection of ``Baryon Wiggles'' in the local galaxy power spectrum and source identification in radio data. Finally, I will look ...
2001-01-01
CR portal imaging; A linac graphy using storage phosphor imaging systems
Energy Technology Data Exchange (ETDEWEB)
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In computed radiography, image processing (tone scale modification and edge enhancement) is possible, and is advantageous portal imaging. When PACS is introduced to the ...
1992-07-01
International Nuclear Information System (INIS)
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In computed radiography, image processing (tone scale modification and edge enhancement) is possible, and is advantageous portal imaging. When PACS is introduced to the ...
1992-01-01
Automatic system for measuring dose-area product (DAP) in ROI fluoroscopy
Energy Technology Data Exchange (ETDEWEB)
A computerized system for monitoring dose-area product (DAP) has been developed for region of interest (ROI) fluoroscopy in which patient exposure is reduced using an x-ray attenuating filter with an aperture. The system includes an IBM compatible computer which is connected through an IEEE-488 interface to an electrometer which measures the charge from a DAP ionization chamber. A digital input/output board connects the computer to the filter placement device to determine whether the filter is in or out of the beam, and to the x-ray generator to determine when the exposure is due to spot filming. The computer logs the DAP from conventional fluoroscopy, ROI fluoroscopy and spot filming separately, applying the appropriate calibration factor for each. Measured DAPs, fluoroscopic DAP rates and exposure times are displayed in real-time. The system has been installed in a GI fluoroscopic room so that the dose-reduction potential of ROI imaging can be evaluated. (author)
1997-04-01
The profusion of online digital images presents new challenges for image indexing. Images have always been problematic to describe and catalogue due to lack of inherent textual data and ambiguity of meaning. An alternative to time-consuming professionally-applied metadata has been sought in the form of tags, simple keywords that form a flat structure known as distributed classification, or more popularly as a folksonomy. This research aims to increase understanding of why people tag and how effective they find it for searching, using as the focus. Open-ended questionnaires were sent out to members of the photo-sharing website Flickr, with the opportunity to post comments to an online discussion space. There is also a systematic comparison between a tag-based system and a more traditional controlled vocabulary, to test out the claims made regarding the suitability of tagging for searching and browsing. For this purpose Flickr has been compared with Getty Images ...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
This work presents a digital adaptive Power System Stabilizer (PSS) which operates in a gain scheduling scheme. It`s parameters are designed for a lot of different operating regions in a P x Q plane (active and reactive powers), and saved in a microcomputer real time control. During working, the PSS identifies the present region of operation, and synthesizes its damping signal in accordance with the parameters for that region. As an extension of the method, a neural PSS, which uses the set of parameters of each region as a standard set to train a neural network to form this PSS, is also proposed. The tests presented show good performance for both PSS, when compared to a conventional (non adaptive) one. (author) 10 refs., 5 figs., 1 tab.; e-mail: jalb at guama.cpgee.ufpa.br
1997-12-31
AC loss measurements of model and full size 50mm SSC collider dipole magnets at Fermilab
Energy Technology Data Exchange (ETDEWEB)
Tests have recently been performed at Fermilab in order to measure the energy losses due to eddy currents and iron and superconductor magnetization. These measurements were performed on six 1.5m long model magnets and eight 15m long full scale collider dipole magnets. AC losses were measured as a function of ramp rate using sawtooth ramps from 500, to 5000 Amps for both types of magnets, while bipolar studies were additionally performed on some of the short magnets. The measured magnet voltage and current for a complete cycle are digitally integrated to yield the energy loss per cycle. Measurement reproducibility is typically 5%, with good agreement between long magnet measurements and extrapolations from short magnet measurement results. Magnetization loss measurements among similar magnet types agree to within experimental error, while eddy current losses correlate strongly with the observed dependence of quench current on ramp rate.
1992-09-01
Energy Technology Data Exchange (ETDEWEB)
This document describes the contents of a digital climatological data set that may be used by raster or vector geographic information systems (GISs). The primary focus of the data set is the quantification of the occurrence of synoptic storms and other climatological factors that affect coastlines. However, recent demands for new and/or improved climatologies of storm events as well as an increase in the availability of source data have made it useful to extend the domain of most of the data variables to that of regional and/or global coverage. The expansion of the data makes the data set applicable in several areas of climatic research. The data set contains eight data groups. Spatial coverage of data varies by data group. All data groups except one are referred to 1{degree} {times} 1{degree} or 5{degree} {times} 5{degree} grid cells of latitude and longitude. (Data group (3) is referenced by state.) 19 refs., 12 figs., 26 tabs.
1991-05-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
