of the digital hearing aid technology that led to the cochlear implant. Former. Marshall Space Flight Center engineers. John Richardson and Joseph Howard ...
A Composite Architecture for Network Security at JPL. Robert B. Mead, Tom G. Dearmond, and Joseph S. Sherif. JPL, California Institute of Technology ...
Abstract: Data currently available in the Ontario Timber Inventory include Canada ... Download 1:250 000 scale Ontario Timber Inventory data in Arc Export ...
During 1978 there was a marked increase in the number of patients with meningococcal infection in the Hamilton area. Of 21 patients admitted to St. Joseph's Hospital, Hamilton, two thirds were under...Full Text Available
An ex-employee's claims that inadequate enforcement of radiation safety regulations allowed excess radiation exposure thereby causing his deteriorating health was not substantiated by a thorough investigation.
Ataxin-3, the protein involved in Machado-Joseph disease, is able to bind ubiquitylated substrates and act as a deubiquitylating enzyme in vitro, and it has been involved in the modulation of protein...Full Text Available
Proposed features of the competitive electricity market in Ontario were reviewed. The speaker predicted that demand for renewable energy in Ontario`s competitive electricity market will be affected by green power, emissions trading, labelling, and renewables portfolio standard. Under current regulations retailers can charge customers a premium for purchasing electricity generated by `green` sources. The existing limits on emissions of sulphur dioxide, nitrogen oxides and carbon dioxides will remain in place, but an emissions cap and trading program for all Ontario-based generation is an option to consider. Ontario`s Market Design Committee (MDC) has recommended the implementation of emissions trading for electricity-related air pollutants for all generators located in Ontario. The complex mechanics of emission trading are explained. The MDC recommendation of the use of standard ...
The study involved 110 randomly selected dairy farms located in the Ontario, Canada counties of Bruce, Grey, Huron, Oxford, Perth, Waterloo and Wellington. Herds were classified as "intensive" and "extensive"....Full Text Available
The purpose of this study was to assess changes in dairy herd milk production and milk composition associated with changes in Salmonella contamination of bulk milk on dairy farms in southwestern Ontario....Full Text Available
To study the occurrence and distribution of various strains of Haemophilus parasuis in southern Ontario swine, organisms isolated from healthy swine, from specific pathogen-free and conventional herds,...Full Text Available
This study describes instructions for after-hours care offered by family physicians' offices when patients telephone the practice. Randomly selected (n=1,680) Ontario family physicians and general practitioners...Full Text Available
ABSTRACTOBJECTIVETo explore the prevalence and the demographic predictors of nonmedical use of opioid analgesics in the Canadian adolescent population.DESIGNData...Full Text Available
Tonsillar and nasal swabs were collected from weanling pigs in 50 representative Ontario swine herds and tested for the presence of 5 important bacterial upper respiratory tract pathogens. All but 1...Full Text Available
Numbers of wintering sea ducks, including buffleheads (Bucephala albeola; BUFF), common goldeneyes (Bucephala clangula; COGO), and long-tailed ducks (Clangula hyemalis; LTDU), increased substantially at Lake Ontario after Dreissenid mussels (Dreissena bugensis and D. polymorpha) colonized the Great Lakes. Invertebrates, including Dreissenid mussels, are major diving duck prey items that can transfer some trace elements, such as selenium (Se) to higher trophic levels. Se can be problematic for waterfowl and it often has been detected at elevated levels in organisms using the Great Lakes. There are, however, few data on hepatic Se concentrations in sea ducks, particularly during the winter at Lake Ontario. In this study, we evaluated interspecific differences and temporal trends in hepatic S...
The paper describes the latest approach to quality engineering in the design process as applied by Ontario Hydro throughout the various phases of the project life cycle for Ontario Hydro generating stations and related facilities. Ontario Hydro has long recognized that the high quality and performance required in nuclear generating stations start in the design process and can best be achieved through an adequate and proper quality engineering programme in design. The current approach has evolved over a period of six years and represents a meaningful and effective series of requirements, functions and activities, which are used to ensure safety, reliability, economy and environmental acceptability of nuclear generating stations. (author).
This report presents results of an air quality assessment program in northwestern Ontario. It includes data from communities where long term monitoring is conducted, mostly in urban areas and near industrial sources of air pollution such as mining, pulp and paper, and thermal power generation. Summaries are also presented of special studies in the Thunder Bay area. The monitoring program identifies pollution sources and assesses the results of pollution control measures. Data are included only on those contaminants routinely monitored in northwestern Ontario, including particulates, CO, NOx, ozone, SO[sub 2], total reduced sulfur, organic compunds, and heavy metals. Data from air quality and meteorological instruments are supplemented by vegetation, soil and snow sampling studies. 25 refs, 14 figs., 16 tabs.
The objective of the current research was to examine the association of herd level disease incidence with the return over feed (ROF) (milk income minus feed cost) herd profit index offered through Canwest...Full Text Available
This paper documents some of the recent uses of robotics for inspection and maintenance activities in Ontario Hydro's nuclear power plants in areas other than fuel channels and steam generators. 7 figs.
BACKGROUND:Canadian chronic pain prevalence estimates range from 11% to 66%, are affected by sampling and measurement bias, and largely represent urban settings.OBJECTIVES:To...Full Text Available
AbstractGenetic-variant analysis of rabies viruses provides the most sensitive epidemiologic tool for following the spread and persistence of these viruses in their wildlife hosts. Since...Full Text Available
OBJECTIVE: To examine primary care physicians' management of rheumatoid arthritis, ascertain the determinants of management and compare management with that recommended by a current practice panel....Full Text Available
... on a transgressive surface; examples from the Silurian Whirlpool Sandstone of southern Ontario, Canada. Journal of Sedimentary ... and C. J. Salas. 1991. The Lower Silurian Whirlpool Sandstone. in Cheel, ...
A microcomputer-based herd management information system was implemented as part of the herd health program provided to 13 dairy clients by the Ontario Veterinary College, University of Guelph. The...Full Text Available
Data from an epidemiological study in Ontario, involving 304 dairy herds, were used to identify associations between selected production indices and lipoarabinomannan antigen serological test results...Full Text Available
The principles of path analysis and causal modelling are discussed. Path analysis was applied to three data sets to assess the relationship between group characteristics (number per group and "mixing"...Full Text Available
The focus of the May-June issue is on training and information technology. Major articles/reports in this issue include: Communicating effectively, by Alain Bucaille, AREVA; Reputation management, by Susan Brisset, Bruce Power; Contol room and HSI modernization guidance, by Joseph Naser, EPRI; How far are we from public acceptance, by Jennifer A. Biedscheid and Murthy Devarakonda, Washington TRU Solutions LLC; Spent fuel management options, by Brent W. Dixon and Steven J. Piet, Idaho National Laboratory; Industry Awards; A secure energy future for America, by George W. Bush, President, United States of America; Vision of the future of nuclear energy, by Anne Lauvergeon, AREVA; and, Plant profile: strategy for transition to digital, TXU Power.
Objective Infectious endophthalmitis is among the most serious complications of cataract surgery. Gram-negative bacteria, including Pseudomonas aeruginosa, are responsible for less than 30% of cases; however, their rapidity of infection and virulence often results in poor visual outcome despite prompt antibiotic treatment. The purpose of this study was to investigate an outbreak of post-cataract surgery P. aeruginosa endophthalmitis in India. Design Hospital-based case series. Participants Twenty patients with acute postoperative endophthalmitis who underwent cataract surgery at one of the peripheral centers of Joseph Eye Hospital, Tiruchirapalli, Tamil Nadu, India, from February 23 to April 2, 2008. Interventions Vitreous aspirates and environmental surveillance specimens were inoculated ...
The principal types of uranium deposits in Ontario are carbonatites and fenites, alkalic volcanic rocks, pegiatites, calc-silicate rocks, pyritic quartz-pebble conglomerates, polymictic conglomerates and some pelitic rocks, and various 'pitchblende' deposits including late Precambrian unconformities, possibly late Precambrian diabase dikes, and other unconformities: carbonates, sandstones, lignites, and semi-pelitic rocks of middle and upper Precambrian age. Only red unzoned pegmatite and the pyritic quartz-pebble conglomerate have supported production. Ontario reasonably assured and estimated resources in the economic and subeconomic categories in 1977 amounted to 553 000 tonnes U, and 1977 production was 4000 tonnes U. Measured, indicated, and inferred resources in the Elliot Lake - Agnew Lake area are at least 400 000 tonnes U. The latter deposits are also a significant thorium resource. Geological features reflecting major changes in ...
Ontario's Countdown Acid Rain program was formulated in 1985 and placed an annual SO{sub 2} emissions cap of 885 kilotonnes over the province from 1994. Caps were placed on emissions from the Inco nickel/copper smelter in Sudbury, the Falconbridge nickel/copper smelter in Sudbury, the Algoma iron ore sintering plant in Wawa, and Ontario Hydro fossil-fuel plants province-wide. Semi-annual reports are required of the companies, with the 6th report outlining the final planning phase and the 7th and later reports outlining implementation progress. This document summarizes the contents of the 7th set of reports and the responses of the government review team to each company's efforts. All companies have begun implementing abatement plans outlined in the final planning phase reports of December 1988 at a rapid pace and are generally on track in controlling emissions. However, all 4 company reports lack the necessary detail for a ...
Abstract Background:- Surgical dislocation of the hip has been developed to deal with the problems causing femoroacetabular impingement (FAI). This is a relatively recent procedure that was historically reserved for larger areas specializing in hip surgery. Methods:- We hypothesized that surgical dislocation can be used for symptomatic FAI in a typical Australasian tertiary orthopaedic centre with acceptable results. This prospective study reviews the results of 53 surgical dislocations in this setting, looking particularly at functional outcomes and early complications. Results:- There were significant improvements in the Western Ontario and McMaster University Osteoarthritis Index score at 1, 2, 3 and 4 years post-operatively. Western Ontario and McMaster University Osteoarthritis Index ...
One hypothesis for the decline of the North American greater (Aythya marila) and lesser (A. affinis) scaup population is that contaminant burdens acquired on wintering or staging areas impair reproduction or cause lethal or sublethal health effects. Recent studies have found increased selenium (Se) concentrations in scaup but have focused on the fall and spring staging periods. From January to March 2006 and December to March 2006 and 2007, we analyzed liver tissues collected from greater scaup wintering in western Lake Ontario for 16 trace elements. We also measured Se concentrations in greater scaup blood and Dreissenid mussel tissue. Se was the only trace element that occurred at increased concentrations (>10??g/g liver dry weight) in a substantial proportion (99%) of greater scaup live...
Details of a 1 day conference designed to create more efficient interactions between the gas supply and electricity systems in Ontario and new models for gas supply and the electricity system were presented. Market efficiency, generators' perspectives on critical gas issues, an overview of the North American gas and an outline of issues concerning Ontario were discussed. A natural gas industry forecast and issues concerning marketers and producers were presented. The terms on which gas is bought and sold were discussed. Regulatory tools, cost allocation and issues relating to unbundling were also presented. Infrastructure needs were reviewed, as well as basic market structures. It was suggested that appropriate commercial service options need to be developed and approved, including cross-utility services.
Numerous studies have shown that large, herbivorous waterfowl can reduce quantity of aquatic plants during the breeding or wintering season, but relatively few document herbivory effects at staging areas. This study was done to determine if feeding activities of tundra swans (Cygnus columbianus columbianus) and Canada geese (Branta canadensis) had a measurable additive influence on the amount of aquatic plants, primarily muskgrass (Chara vulgaris), wild celery (Vallisneria americana), and sago pondweed (Potamogeton pectinatus), removed during the fall migration period at Long Point, Lake Erie, Ontario. Exclosure experiments done in fall 1998 and 1999 showed that, as compared to ducks and abiotic factors, these two large herbivorous waterfowl did not have any additional impact on above or b...
Modern microprocessor-based relays for the protection of the various power system components such as generators, transformers, feeders, and high voltage transmission lines are becoming more sophisticated as increasingly more complex functions and capabilities can be included in the microprocessor. With this increasing complexity, and the increasing complexity of the power system itself, there is even more value in testing the suitability of relaying equipment for the intended applications. This paper reviews the testing philosophy, experience, and capabilities developed at Ontario Hydro over more than 25 years of testing protective relays.
Background:Timely access to publicly funded health services is a priority issue across the healthcare continuum in Canada. The purpose of this study was to examine wait list management...Full Text Available
This article examines the developing market for independent power projects in Canada. The topics of the article include bidding in Ontario, the Quebec market, powering British Columbia, and market forces at work in Canada. Discussed are current projects in all stages of completion from bidding to production and includes gas-fired cogeneration, gas-fired combined-cycle electricity generation and cogeneration, wood-waste fired plants, repowering of existing utility plants, and hydroelectric power plants.
In the fall of 2003, the operators noticed that in the recently-refurbished Bruce A Shutdown System no. 1 (SDS1) the noise level in Log Rate signals were much larger than before. At the request of the Canadian Nuclear Safety Commission (CNSC), all Canadian CANDU reactors took action to characterize their Log Rate noise. Staff of the Inspection and Maintenance Services division of Ontario Power Generation (OPG) has collected high-speed high-accuracy noise data from nearly all 16 Ontario reactors, either as part of routine measurements before planned outages or as a dedicated noise recording. This paper gives the results of examining a suitable subset of this data, with respect to the characteristics and possible causes of Log Rate noise. The reactor and instrumentation design is different at each station: the locations of the moderator injection nozzles, the location of the ion chambers for each system, and the design of the Log Rate amplifiers. ...
This report describes selective catalytic reduction (SCR) technologies which offer an economical and effective means of reducing nitrogen oxide emissions from electricity generation facilities and reviews the feasibility and cost effectiveness of employing this technology on electricity generating facilities in Ontario. Based on experiences in the United States, in British Columbia, and internationally in Japan and Germany, the indication is that the technology for the installation of SCR systems on new gas-fired combined cycle power plants and existing coal-fired power plants has grown enormously during the past decade, and has been established as the control technology of choice for nitrogen oxide emissions. It is widely acknowledged to reduce power plant nitrogen oxide emissions, and do so at a very reasonable incremental cost. It is estimated that the annualized cost of installing and operating a SCR at a large gas-fired combined cycle facility in ...
Recent advances in elastic-plastic fracture mechanics have made it possible to assess the stability of cracks in ductile piping systems. These technological developments have been used by Ontario Hydro as the nucleus of an approach for demonstrating that CANDU primary heat transport piping systems will not break catastrophically; at worst they would leak at a detectable rate. This leak-before-break approach has been taken on the Darlington nuclear generating station as a design stage alternative to the provision of pipe whip restraints on large diameter, primary heat transport system piping. Positive conclusions reached via this approach are considered sufficient to exclude the requirement to provide protective devices, such as pipe whip restraints. In arriving at the proposed leak-before-break approach a review of current and proposed leak-before-break licensing positions of other jurisdictions (particularly those in the United States and the Federal Republic of ...
Issues regarding the development of mechanisms to reduce greenhouse gas emissions in the electricity sector are discussed. Environmental groups have proposed mechanisms such as carbon taxes. Three other mechanisms have also been proposed under the Framework Convention on Climate Change (FCCC). These include the Clean Development Mechanism, Joint Implementation and carbon trading. A pilot emission reduction trading project began in Ontario in 1996 as an initiative to control smog and ozone in the southern provincial airshed. Substances of interest include NO{sub x}, volatile organic compounds (VOCs), SO{sub x}, carbon monoxide and other greenhouse gases. Ontario Hydro alone has conducted 10 trades, five with companies in the U.S., two of those for carbon emissions. An analysis of the pilot trade deals will provide an idea of the value of this mechanism. In addition to details of the trades, this article also addresses concerns regarding the ...
This document provides information and presents data on the energy situation in many regions of Canada. The first part deals with the petroleum and the bitumen shales of Alberta (reserves, exploitation and production, environmental impacts), the second part discusses with the hydroelectricity choice of Quebec and the 2004 crisis. The nuclear situation of Ontario is presented in the third part (nuclear park, programs, uranium reserves, research and development on Candu reactors), while the fourth part deals with the renewable energies (wind power and biomass). The canadian situation facing the Kyoto protocol is discussed in the last part. (A.L.B.)
This forum provided insights into Ontario's new smart meter program. Challenges related to implementing the smart meter program were reviewed, and various functional and operational considerations of the meters were considered. The implications and benefits of using real time metering systems were discussed along with issues related to energy conservation and demand management. Various communications technologies were considered in relation to smart metering program implementation. Issues related to pricing and pricing policies were also discussed. The conference featured 11 presentations, of which 2 have been catalogued separately for inclusion in this database. refs., tabs., figs.
This document presents an assessment of the severe accident phenomena observed from four Full-Length High-Temperature (FLHT) tests that were performed by the Pacific Northwest Laboratory (PNL) in the National Research Universal (NRU) reactor at Chalk River, Ontario, Canada. These tests were conducted for the US Nuclear Regulatory Commission (NRC) as part of the Severe Accident Research Program. The objectives of the test were to simulate conditions and provide information on the behavior of full-length fuel rods during hypothetical, small-break, loss-of-coolant severe accidents, in commercial light water reactors.
...assistantship in Suburban Ecology Location: Bedford, NY Deadline: August 15, 2008 Postdoctoral Fellow in energy Location: University of Waterloo, Ontario, Canada Deadline: August 11, 2008 Junior Professional Fellowship Sustainable Development Governance Programme Location: UNU, Yokohama, Japan Deadline: August 1, 2008 Center for Ocean Solutions Early Career Fellowship Program Location: Stanford, California Deadline: July 15, 2008 Asian MetaCentre for Population and Sustainable Development Analysis Postdoctoral Research Fellow Location: Singapore Deadline: July 15, ...
The bituminzation of decontamination and ion exchange resin stripping wastes with four grades of asphalt was investigated to determine the effects of asphalt type on the properties of the final products. All waste forms deformed readily under light loads indicating they would flow if not restrained. It was observed in all cases that product leaching rates increased as the hardness of the asphalt used to treat the waste increased. If bituminization is adopted for any Ontario Hydro aqueous radioactive wastes they should be treated with soft asphalt to obtain optimum leaching resistance and mechanical stability during interim storage should be provided by a corrosion resistant container.
The SY-101 Equipment Removal System 100 Ton Hydraulic Trailer was designed and built by KAMP Systems, Inc. Performance of the Acceptance Test Procedure at KAMP`s facility in Ontario, California (termed Phase 1 in this report) was interrupted by discrepancies noted with the main hydraulic cylinder. The main cylinder was removed and sent to REMCO for repair while the trailer was sent to Lampson`s facility in Pasco, Washington. The Acceptance Test Procedure was modified and performance resumed at Lampson (termed Phase 2 in this report) after receipt of the repaired cylinder. At the successful conclusion of Phase 2 testing the trailer was accepted as meeting all the performance criteria specified.
Ontario's electricity industry restructuring program is reviewed, with a view to identify the reasons behind the failure of deregulation which was expected to create competition, to stabilize, or even reduce, prices to consumers, and attract serious private sector investment for the construction of new generating capacity. The report painstakingly reviews the series of events which resulted in a steep rise in electricity rates during the summer of 2002, immediately after deregulation came into effect, which led to freezing retail electricity rates and related charges by the then Conservative provincial government, and the reversal of that decision by the newly-elected Liberal government in the fall of 2003, and plans to bring back retail hydro rates that reflect the cost of production. The authors provide a discussion of policy options and a series of recommendations that are expected to create incentives to reduce and shift demand, encourage the use of ...
An update of Toronto Hydro's smart metering program was presented. Electricity demand is expected to keep increasing, and there is presently insufficient generation to match supply needs in Ontario. The smart metering program was introduced to aid in the Ontario government's energy conservation strategy, as well as to address peak supply problems that have led to power outages. It is expected that the smart metering program will reduce provincial peak supply by 5 per cent, as the meters support both time-of-use rates and critical peak pricing. Over 800,000 smart meters will be supplied to customers by 2007, and all 4.3 million homes in Toronto will have a smart meter by 2010. In order to meet targets for 2010, the utility will continue to install more 15,000 meters each month for the next 4 years. While the Ontario government has planned and coordinated the rollout and developed smart metering ...
We used a 13-year time series of abundance estimates of breeding Northern Saw-whet Owls (Aegolius acadicus), and of small mammals from central Ontario, Canada, to assess the numerical response of the owls to small-mammal prey species. We found that the finite rate of increase of breeding owls was directly related to estimates of red-backed vole (Myodes gapperi) abundance. Thus, it appeared that the owls were nomadic, and made decisions about where to breed based on vole supply. The owls showed a much weaker response to deer mouse (Peromyscus maniculatus) abundance. Across all years, 55% of variation in owl rate of increase could be uniquely attributed to vole abundance, whereas only 3% could be attributed to mouse abundance. Consistent with the model of nomadism, there was only a weak rela...
Aerial deposition of Ni from a refinery in Port Colborne, Ontario, Canada has resulted in the enrichment of 29km2 of land with Ni concentrations exceeding the Canadian Ministry of the Environment's remedial action level of 200mgkg-1. Several studies on these soils have shown that making the soils calcareous was effective at reducing chemically extractable Ni, as well as alleviating Ni phytotoxicity symptoms in vegetable crops grown in the vicinity of the refinery. Conversely, dolomitic limestone additions resulted in increased uptake of Ni in the Ni hyperaccumulator Alyssum murale `Kotodesh', a plant whose use was proposed as a remediation strategy for this area. In this paper we use multiple techniques to directly assess the role soil type and lime treatments play in altering the speciati...
The chronology of installing solar power in a rural area of Ontario is described. The installation took all of seven years, and was characterized by a lot of joy, but also a lot of heartache and hardship, all of which are chronicled in this article. The project started with four solar modules generating 300 watts, nickel cadmium batteries of 225 Ah, an inverter of 600 watt, and a three-cylinder 6.5 Kw water-cooled propane generator. Today, nearly seven years later, the installation consists of 18 solar modules supplying 1350 watts of power, lead-acid batteries of 2770 Ah, a 2500 watt inverter, a one cylinder, 5.5 kw propane-gasoline generator, a heated, underground generator house, complete with an amp-hour meter and MPPT charge controller.
Knee osteoarthritis (OA) is a common degenerative joint disorder and a major cause of pain and disability. The hypothesis tested in this study was that the passion fruit peel extract (PFP), a flavonoid-rich dietary supplement, would reduce symptoms due to knee OA. Thirty-three OA patients were enrolled in a randomized, double-blind, placebo-controlled trial with parallel-group design. Patients received either placebo or PFP pills (150 mg, daily) in a double-blinded fashion for 2 months. The OA clinical symptoms were evaluated monthly with Western Ontario and McMaster Universities (WOMAC) Osteoarthritis Index. In the PFP group, there was a significant improvement in total WOMAC score and WOMAC subscale score of physical function after 30 days and pain after 60 days. At 60 days, reductions o...
Parents who contacted 1 of 15 children?s mental health agencies in Ontario, Canada reported on where and why they were seeking mental health services for their 4- to 17-year-old children. Parents contacted?an average of four agencies (?1.7; range?=?1?14) in the previous year. Approximately one-half of parents were looking for either multiple types of treatment, or help for different problems, across agencies. The complex pattern of help-seeking evidenced in our study likely increases the burden on the mental health care system and on families, and may reduce the likelihood that families will connect with the most appropriate treatment.
This article reports on the world's first gas turbine to top 40% thermal efficiency in simple cycle and is now operating commercially as part of a natural-gas-fired combined-cycle cogeneration (CC) plant serving the Ottawa Health Sciences Center, Ottawa, Ont, Canada. Owned and operated by TransAlta Energy Corp, Calgary, Alta, the CC plant supplies steam and hot and chilled water to the health center and another thermal user while the electricity is sold to Ontario Hydro. Part of the project included the conversion of 15-psig steam-carrying equipment to hot-water service. Commercial success of this installation heralds a new era in the application of efficient gas turbines for power generation.
This collection contains 20 papers written by educators, administrators and information scientists who had conducted manpower surveys in the library and information fields: (1) "Background and Evolution of Educational Planning and Forecasting for Information Manpower" (Yves Courrier); (2) "Indicators for the Emerging Information Market" (Nick Moore); (3) "Information Scientists in the English-Speaking Caribbean: Challenges and Responses in the Development Process" (Gloria Greene, Reive Robb); (4) "National Survey on Manpower in Libraries, Information Centres and Archives in Thailand" (Suwakhon Phadungath); (5) "Predicting the Future: Manpower Forecasting for the Library and Information Professions in Southern Africa" (J. R. Neill, D. M. Mbaakanyi); (6) "Problems in Forecasting Manpower Needs" (Monique Jucquois-Delpierre); (7) "Electronic Measures for Human Resource Research" (Anthony Debons, Mariano Maura-Sardo, Anne Thompson); (8) "The Intersection of Communication and Information: ...
AbstractOBJECTIVETo provide an overview of the 2009 edition of the Rourke Baby Record (RBR), which incorporates recent research in the literature relating to preventive health care for children aged 0 to 5 years.QUALITY OF EVIDENCERecommendations are identified as supported by good, fair, or consensus evidence, according to the classification of the Canadian Task Force on Preventive Health Care.MAIN MESSAGENew information and recommendations are given for growth monitoring, nutrition, developmental surveillance, physical examination maneuvers, immunization schedules, and advice for parents. Anticipatory guidance updates relate to injury prevention, infant swaddling, literacy facilitation, nonparental child care, parenting skills programs, serum lead levels, over-the-counter cough and cold medications, pacifiers, antipyretics, insect repellents, and dental care and oral health. The 2009 RBR is available in English and French in both National and Ontario versions and ...
Lake Erie, the southernmost of the Laurentian Great Lakes, is narrow and relatively shallow in comparison to other Great Lakes. The lake experiences extreme water level fluctuations and storm energy restricts the development of wetlands to protected areas within embayments, lagoons, or behind barriers. However, coastal marshes of western Lake Erie fringe the shorelines of Michigan, Ohio, and Ontario and encompass an area of 268 km/sup 2/. This publication reviews the ecological data and information on the wetlands of Lake Erie, which are some of the more productive areas in the Great Lakes ecosystem. The geologic history of the Lake Erie leading to the development of wetlands, the present environment, and present wetland distribution are presented as background in the opening chapters. Biological information available for the Lake Erie wetlands is discussed in detail, and ecological processes contributing to the evolution of wetlands, biological production, and ...
The recent attempt to degassify a self contained liquid filled (SCLF) cable in Ontario Hydro is described. In September 1989, there was a high pressure alarm on one phase of a SCLF 115 kV cable circuit. The direct buried cable circuit is about 1,890 m long with two joints and was installed in 1968. Oil samples from the cable had 10 to 12% gas content with high levels of hydrogen, methane, and ethane, and very low levels of carbon monoxide, carbon dioxide, and acetylene. From these results it was concluded that the gas was generated by low energy electrical discharges and the paper insulation was not degraded. Various utilities and cable manufacturers were contacted to find if they had experienced similar problems. The cable duct oil was flushed and gasified and the successive oil samples were analyzed in order to locate the gassing site. The joints were examined and oil samples were taken through holes drilled in the cable sheath. From the test results the problem ...
Nova Corporation and its related businesses are involved in natural gas production, gas pipelines, consulting services, and upgrading of natural gas into chemicals and plastics. Nova owns Alberta Gas Transmission Division, the primary gas transportation system in Alberta, with 11,400 miles of pipeline and total deliveries in 1992 of 3.4 trillion ft"3. Nova also owns 50% of Foothills Pipe Lines Ltd., one of Canada's largest carriers of exported gas, and 50% of TQM Pipeline Partnership, which transports natural gas in Quebec. Nova conducts its chemicals business through Novacor Chemicals Ltd., which has plants in Alberta, Ontario, Quebec, and the USA. Novacor's major petrochemicals are methanol, ethylene, propylene, and styrene and its major plastics are polystyrene, polypropylene, and polyethylene. Nova's gas-producing branch Novalta Resources produced 26 billion ft"3 of natural gas in 1992 and has proven reserves of 334 billion ft"3. Nova's net income in 1992 was ...
A field study was conducted in Ontario to evaluate the suitability of grouted piles for transmission tower foundations. The grouted piles were assessed in terms of the installation procedure and its foundation performance subjected to uplift loads. Two types of grouted piles, the H-pile and the pipe-pile, were evaluated and compared with conventional ungrouted H-pile foundations. Difficult soil conditions were encountered consisting of a deep deposit of loose to compact sand with a high water table. Both the grouted pipe-pile and the grouted H-pile developed uplift capacities more than double that of the conventional H-pile with the same embedment length at the test site. The grouted H-pile is recommended as a viable transmission line foundation in weak soils due to the significant improvement in its foundation performance, with minor modifications to the construction procedure. 3 refs., 17 figs., 12 tabs.
Cost is a key issue in the spreading of any technology. In this work, the cost of hydrogen is analyzed and determined, for hydrogen obtained by electrolysis. Different contributing partial costs are taken into account to calculate the hydrogen final cost, such as energy and electrolyzers taxes. Energy cost data is taken from official URLs, while electrolyzer costs are obtained from commercial companies. The analysis is accomplished under different hypothesis, and for different countries: Germany, France, Austria, Switzerland, Spain and the Canadian region of Ontario. Finally, the obtained costs are compared to those of the most used fossil fuels, both in the automotive industry (gasoline and diesel) and in the residential sector (butane, coal, town gas and wood), and the possibilities of hydrogen competing against fuels are discussed. According to this work, in the automotive industry, even neglecting subsidies, hydrogen can compete with fossil fuels. Hydrogen can ...
Sulfur dioxide emissions from an iron ore sintering plant have severely damaged vegetation up to 16 km northeast of the source. Concentric zones of increasing vegetation loss have formed around the point of maximum ground level concentration of the gas. Species diversity, sulfur and heavy metal concentrations in vegetation and soil amount to SO/sub 2/ injury were measured along a transect through the injury zones. Surrounding a central denuded area were zones dominated respectively by tussock-forming hair grass (Deschampsia flexuosa); low-growing shrubs and trailers (Sambucus pubens, Polygonum cilinode); higher-growing shrubs and suckering Populus tremuloides and Betula papyrifera) stunted forest tree species (Populus, Betula, Picea glauca, Abies Balsamea), and finally, normal boreal forest flora. Although SO/sub 2/ injury is continuing in this area, these zones now appear to be maintained primarily by severe erosion and destruction of suitable habitats for regeneration of forest ...
This report presents and discusses results from Task 5 of the study ''Fate of Mercury in Synthetic Gypsum Used for Wallboard Production,'' performed at a full-scale commercial wallboard plant. Synthetic gypsum produced by wet flue gas desulfurization (FGD) systems on coal-fired power plants is commonly used in the manufacture of wallboard. The FGD process is used to control the sulfur dioxide emissions which would result in acid rain if not controlled. This practice has long benefited the environment by recycling the FGD gypsum byproduct, which is becoming available in increasing quantities, decreasing the need to landfill this material, and increasing the sustainable design of the wallboard product. However, new concerns have arisen as recent mercury control strategies developed for power plants involve the capture of mercury in FGD systems. The objective of this study is to determine whether any mercury is released into the atmosphere when the ...
The transport and partitioning of {sup 129}I has been examined for a shallow groundwater flow system at Sturgeon Falls in northeastern Ontario. Recharge into a sandy surficial postglacial deltaic aquifer occurs in the vicinity of a seasonally-wet boreal forest. Concentrations of stable iodine, {sup 129}I, tritium, radiocarbon, stable isotopes and major ions were measured on samples of groundwater and precipitation. The present-day tritium profile delineates the position of the early 1960's above-ground nuclear weapons pulse at a depth of approximately 12 m. The concentrations of stable iodine for groundwaters above, near and below the above-ground nuclear weapons pulse range from 0.07 to 1.7 ppb. Over that same interval {sup 129}I concentrations decreased from 1.9 x 10{sup 6} atoms/L at 9 m, to approximately 1.9 x 10{sup 5} atoms/L in tritium-depleted waters at 35 m, below the present-day depth of the recharging above-ground nuclear weapons peak at ...
Wasaga Distribution Inc. is located on Georgian Bay in one of the fastest growing communities in Ontario. It has a customer base of 10,400 residential customers in a service territory of 61 square kilometres. This presentation outlined Wasaga's experience with the Itron fixed network 2.0 RF Centron IDM meter. It outlined the dataflow features and capabilities of the meter in terms electricity endpoints, repeaters, and neighbourhood collectors. The repeater is designed to capture ERT IDM reads and retransmit at a higher power. The meter is also designed to reduce the number of cell control units (CCU) necessary to cover an area. The meter sleeve design allows for simple and cost effective installation, and has a bandwidth capable of over 3000 reads per second. The Itron CCU4 is a listening receiver that captures ERT reads and transmits the data to the utilities. It has a battery back up that lasts 4 hours in case of a power outage. It can be mounted on a ...
Natural Resources Canada commissioned an informal survey in which 18 organizations, mainly utilities from across Canada were contacted by letter or fax to gather data regarding unit energy consumption (UEC) of space heating, domestic hot water (DHW) heating and appliances. The data was used in updating and refining the residential energy end-use model used at NRCan. The survey included energy load, UEC, efficiency, and per cent saturation for both space heating and water heating equipment for all fuel types including electric, natural gas, oil, wood and propane used in single detached, single attached, apartment and mobile homes. A list of UEC and per cent saturation for major appliances such as refrigerators, freezers, clothes washers and dryers, cooktop/ovens, central air-conditioners, and lighting is also included in the survey. The collected data was presented separately for each organization. The UEC estimates for appliances range from 6255 to 8744 kWh/year. The lowest appliance ...
No information on steam/water two-phase flow behavior in large diameter pipes (10 inch or larger) at elevated pressures is available in the open literature. However, there are many applications, in the nuclear, chemical and petroleum industries among others where two-phase flows in large diameter pipes at elevated pressures and temperatures are encountered routinely or under accident scenarios. Experimental data on steam-water two-phase flow in a large diameter (20 inch, 50.08 cm I.D.) vertical pipe at elevated pressures and temperatures (2.8 MPa/230 C--6.4 MPa/280 C) have been obtained. Void fraction, two-phase mass flux, phase and velocity distributions as well as pressure drop along the test pipe have been measured using the Ontario Hydro Technologies (OHT) Pump Test Loop. The void fraction distributions were found to be axially symmetric and nearly flat over a wide range of two-phase flow conditions. The two-phase flow regime could be inferred from the dynamic ...
No information on steam/water two-phase flow behavior in large diameter pipes (10 inch or larger) at elevated pressures is available in the open literature. However, there are many applications, in the nuclear, chemical and petroleum industries among others where two-phase flows in large diameter pipes at elevated pressures and temperatures are encountered routinely or under accident scenarios. Experimental data on steam-water two-phase flow in a large diameter (20 inch, 50.08 cm I.D.) vertical pipe at elevated pressures and temperatures (2.8 MPa/230 C--6.4 MPa/280 C) have been obtained. Void fraction, two-phase mass flux, phase and velocity distributions as well as pressure drop along the test pipe have been measured using the Ontario Hydro Technologies (OHT) Pump Test Loop. The void fraction distributions were found to be axially symmetric and nearly flat over a wide range of two-phase flow conditions. The two-phase flow regime could be inferred from the dynamic ...
TransCanada Pipelines Limited submitted an application to the National Energy Board for new facilities to increase natural gas deliveries to its domestic and export markets. The proposed facilities consist of 1,590 km of pipeline, 21 new compressor units and two new compressor stations. The total cost of the facilities was estimated at $2,408 million. The Board considered at the hearing 15 applications made pursuant to Part IV of the National Energy Board Act for gas exports at existing delivery points at Emerson and Niagra Falls as well as at proposed new delivery points at Chippawa and Iroquois, Ontario. Twelve of these applications were filed in support of TransCanada's facilities application. Five applications were also filed pursuant to section 71 of the National Energy Board Act for orders requiring TransCanada to receive, transport and deliver natural gas offered by the applicants and to provide adequate and suitable facilities to do so. A public ...
TransCanada Pipelines Limited submitted an application to the National Energy Board for new facilities to increase natural gas deliveries to its domestic and export markets. The proposed facilities consist of 1,590 km of pipeline, 21 new compressor units and two new compressor stations. The total cost of the facilities was estimated at $2,408 million. The Board considered at the hearing 15 applications made pursuant to Part IV of the National Energy Board Act for gas exports at existing delivery points at Emerson and Niagra Falls as well as at proposed new delivery points at Chippawa and Iroquois, Ontario. Twelve of these applications were filed in support of TransCanada's facilities application. Five applications were also filed pursuant to section 71 of the National Energy Board Act for orders requiring TransCanada to receive, transport and deliver natural gas offered by the applicants and to provide adequate and suitable facilities to do so. A public ...
A theoretical model is developed to explain variations in airborne gamma-ray measurements over a calibration range near Ottawa, Ontario. The gamma-ray flux from potassium and the thorium decay series showed an expected decrease with increasing soil moisture. However, the gamma-ray flux from the uranium decay series was highest in the spring when the ground was water-saturated and even covered with snow. These results are explained through the build-up of radon and its associated gamma-ray-emitting decay products in the clay soil of the calibration range with increasing soil moisture. Similar results were found from airborne measurements over other clay soils. However, measurements over sandy soils showed that the count rates from all three radio elements increased with decreasing soil moisture. This difference between soil types was attributed to the lower radon emanation of the more coarse-grained sandy soils compared to finer-grained clay soils. The theoretical ...
A theoretical model is developed to explain variations in airborne gamma-ray measurements over a calibration range near Ottawa, Ontario. The gamma-ray flux from potassium and the thorium decay series showed an expected decrease with increasing soil moisture. However, the gamma-ray flux from the uranium decay series was highest in the spring when the ground was water-saturated and even covered with snow. These results are explained through the build-up of radon and its associated gamma-ray-emitting decay products in the clay soil of the calibration range with increasing soil moisture. Similar results were found from airborne measurements over other clay soils. However, measurements over sandy soils showed that the count rates from all three radio elements increased with decreasing soil moisture. This difference between soil types was attributed to the lower radon emanation of the more coarse-grained sandy soils compared to finer-grained clay soils. The theoretical ...
The 24 papers presented at the conference on Neutralisation des eaux de drainage dans l'environnement minier (NEDEM) (Mine Environment Neutral Drainage (MEND)) 2000 symposium on research on innovative methods to control acid mine drainage, covered eight sessions with both technical and general interest papers. The technical papers covered the topics of acid mine drainage and remediation measures, such as flooding, soil cover with various materials, encapsulation, and others. Other topics discussed included the freeze-thaw cycle and its effect on the performance of soil covers. The environmental impacts of acid mine drainage were also described. Some case studies were included to further illustrate the environmental impacts of acid mine drainage and to demonstrate the effectiveness of remedial actions in specific situations. Most of the cases studied were mines located in Quebec and Northern Ontario, with some in British Columbia. The general interest ...
Oil/electric heating systems and energy measuring instrumentation were installed in 50 houses in Deep River, Ontario. These were operated and monitored for two heating seasons to demonstrate their performance and determine the percentage oil placement as a function of heater capacity and control system. All experimental data was stored and processed by computer. It was found that oil furnace utilization efficiency varied from 48 to 59% for an average of 53.5%. Oil displacement ranged from 49 to 83% for 2.5 and 5.0 kW electric heaters controlled by two-stage indoor thermostats. Fuel costs for oil/electric hybrid heating, with 5.0 kW plenum heaters and indoor two-stage thermostats, were 20% less than for oil heating, based on average furnace efficency and 1983 January retail fuel prices. Annual load factors above 37% were achieved for plenum heaters compared to 11.9% for all-electric systems. Space heating requirements were proportional to heating degree days ...
A home-made 3.1 kWh wind turbine that is promising to be the hottest new wind product to appear for home/farm users in some time, is described. The turbine is installed near a farm house in the high wind area of Mount Forest, Ontario. The turbine is hooked up to a four kilowatt Trace inverter charger which is coupled through a DC disconnect and C-60 charge controller to two sets of solar panels (seven panels of 120 W each by Solarex SX 120, and five panels by Sharp, each providing 1600 watt of solar power). The wind turbine and the solar panels, assisted by two 65-year old refurbished wind turbines, one bank of Gel Cell batteries, and an Onan 5 kW gas generator supply the electrical requirements of a seven member family in a 3400 square foot house. The new turbine is mounted on an 80-foot tower, has three eight foot Kevlar blades that produce a 17 foot overall sweep. The turbine weighs 615 lbs., produces 3.1 kW of pure power at just 310 rpms at a low start up wind ...
Samples from three mine tailings, the Hemlo Mine (located in Northern Ontario), the Louvicourt Mine, and the Laronde Mine (both located in Northwestern Quebec) and four different types of hydraulic binder in three different proportions (3, 4.5, 6 per cent of total dry weight of tailings) were used to prepare 33 recipes for cement caulk. The sulphur content of the three tailings is, respectively, 5 per cent, 16 per cent, and 32 per cent. Three of the four hydraulic binders are in fact a mix of two cement types: binder based on Portland cement (CP), binder based on fly ash (FA), and binder based on dross (CL). The fourth binder is based mainly on dross. The coupons of caulk dykes were flushed at 14, 28, 56, and 91 days in a humid chamber. At each of these steps, the samples were characterized for chemical, geochemical, physical, microstructural, and mechanical attributes to better understand the hydrogeochemical properties of the caulk dykes. The geochemical ...
If geothermal heat pumps (GHPs) are to make a significant mark in the market, we believe that it will be through energy service pricing contracts offered by retailcos. The benefits of GHPs are ideally suited to energy service pricing (ESP) contractual arrangements; however, few retailcos are thoroughly familiar with the benefits of GHPs. Many of the same barriers that have prevented GHPs from reaching their full potential in the current market environment remain in place for retailcos. A lack of awareness, concerns over the actual efficiencies of GHPs, perceptions of extremely high first costs, unknown records for maintenance costs, etc. have all contributed to limited adoption of GHP technology. These same factors are of concern to retailcos as they contemplate long term customer contracts. The central focus of this project was the creation of models, using actual GHP operating data and the experience of seasoned professionals, to simulate the financial performance of GHPs in ...
This report investigates methods to utilize existing bulk tobacco kilns for curing (drying) of shelled corn, peanuts, and baled hay. In recent years Ontario tobacco producers have had to reduce production levels due to a declining demand for flue-cured tobacco. Many tobacco producers are currently diversifying into other crops. Some of these crops require curing and/or storage. Because of high capital costs to purchase conventional curing and/or storage facilities, tobacco producers wish to reduce their initial diversification costs by modifying their existing tobacco kilns (tobacco drying structures) and/or tobacco storage barns for this purpose. The investigation included high profile and low profile downdraft stick kilns, bulk kilns, and tobacco storage (pack) barns. Corn, peanuts, and hay were considered in relation to bulk kiln specifications and modifications, handling, drying and storage methods, energy requirements, cost, and quality of end product. The ...
An estimate of the tritium dose to the public in the vicinity of the heavy water research reactor facility at AECL-Chalk River Laboratories, Ontario, Canada, has largely been accomplished from analyses on regularly-collected samples of air, precipitation, drinking water and foodstuffs (pasture, fruit, vegetables and milk) and environmental dose models. To increase the confidence with which public doses are calculated, tritium doses were estimated directly from the ratio of tritiated species in urine samples from members of the general public. Single cumulative 24 h urine samples from a few adults living in the vicinity of the heavy-water research reactor facility at Chalk River Laboratories, Canada were collected and analysed for tritiated water and organically bound tritium. The participants were from Ottawa (200 km east), Deep River (10 km west) and Chalk River Laboratories. Tritiated water concentrations in urine ranged from 6.5 Bq.l{sup -1} for the Ottawa ...