WorldWideScience
 
 
1

A new alkaloid isolated from Maytenus guianensis  

International Nuclear Information System (INIS)

Portuguese (Jul 1981). Brazil Sousa, JR de Souza, E. de . Minas Gerais Univ.,

2

Energy consumption scenarios for the fertilizer industry; Cenarios e consumo de energia na industria de fertilizantes  

Energy Technology Data Exchange (ETDEWEB)

This paper shows the characteristics of the fertilizer production park of the State of Minas Gerais, Brazil, mainly in the aspects of energy consumption and energy sources used in the production process of the various kinds of fertilizers and by-products. A scenario including the fertilizer production evolution was made, relating this future production with the future energy consumption of this sector. 7 figs., 2 tabs.

1991-12-31

3

Determination of Ca, Cr, Cu, Fe, K, Mg, Na and Zn in Brazilian medicinal plants by neutron activation and atomic absorption; Determinacao de Ca, Cr, Cu, Fe, K, Mg, Na e Zn em plantas medicinais brasileiras por ativacao neutronica e absorcao atomica  

Energy Technology Data Exchange (ETDEWEB)

Medicinal plants are available in the markets in Belo Horizonte, Minas Gerais. The objective of this work is to investigate the Ca, Cr, Cu, Fe, K, Mg, Na e Zn concentrations in two lots of usually known diuretics plants (azeitona do mato, cabelo de milho, cavalinha, cervejinha do campo, chapeu de couro, congonha de bugre, marmelinho do campo and quebra pedra) bought with an interval of time - six months - between the purchases. The elemental concentrations were determined applying k{sub 0} instrumental neutron activation analysis and atomic absorption spectrophotometry analysis. (author)

2002-07-01

4

Technical-economic evaluation of the utilization of closing resistor in CEMIG extra-high voltage circuit breakers  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the technical and economic studies performed by CEMIG, Companhia Energetica de Minas Gerais, Brazil, concerning the use of closing resistor in its extra-high voltage (EHV) breakers. The analysis emphasizes the advantages which could be achieved with the elimination of the resistor as far as costs and reliability are concerned. This evaluation was motivated by two 500 kV breaker failures resulting from the breakdown of the closing resistor operation mechanism. These occurrences resulted in operative restriction for CEMIG EHV system. The analysis demanded a review of the capability criteria of silicon carbide (Si C) gap arresters, which are still greatly used in CEMIG EHV System, and of the procedures to be applied when carrying out the transient studies. The investigation resulted in the prompt removal of closing resistors from circuit breakers in CEMIG extra-high voltage system generating an economy of approximately U$ ...

1994-12-31