WorldWideScience
1

Proceedings of the workshop on molten salts technology and computer simulation  

Energy Technology Data Exchange (ETDEWEB)

Applications of molten salts technology to separation and synthesis of materials have been studied eagerly, which would develop new fields of materials science. Research Group for Actinides Science, Department of Materials Science, Japan Atomic Energy Research Institute (JAERI), together with Reprocessing and Recycle Technology Division, Atomic Energy Society of Japan, organized the Workshop on Molten Salts Technology and Computer Simulation at Tokai Research Establishment, JAERI on July 18, 2001. In the workshop eleven lectures were made and lively discussions were there on the fundamentals and applications of the molten salts technology that covered the structure and basic properties of molten salts, the pyrochemical reprocessing technology and the relevant computer simulation. The 10 of the presented papers are indexed individually. (J.P.N.)

2001-12-01

2

Radiotherapy quality insurance by individualized in vivo dosimetry: state of the art; Dosimetrie individuelle in vivo pour le controle de qualite en radiotherapie: etat de l'art  

Energy Technology Data Exchange (ETDEWEB)

The quality insurance in radiotherapy in the frame of highly complex technical process as Intensity modulated radiotherapy (I.M.R.T.) needs independent control of the delivered dose to the patient. Actually, up to now, most of the radiotherapy treatments rely only on computed dosimetry through a rather complicated series of linked simulation tool. This dosimetry approach requires also qualified treatment means based on cautious quality insurance procedures. However, erroneous parameters could be difficult to detect and systematical errors could happen leading to radiotherapy accidents. In this context, in vivo dosimetry has a critical role of final control of the delivered dose. As many beam incidences and ports are used for any photon therapy treatment, external control could be very tedious and time consuming. Therefore, innovations are needed for in vivo dosimetry to provide ...

2009-06-15

3

INL Advanced Radiotherapy Research Program Annual Report 2004  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the activities and major accomplishments for the Idaho National Laboratory Advanced Radiotherapy Research Program for calendar year 2004. Topics covered include boron analysis in biological samples, computational dosimetry and treatment planning software development, medical neutron source development and characterization, and collaborative dosimetry studies at the RA-1 facility in Buenos Aires, Argentina.

2005-06-01

4

Report on progress of researches by common utilization of JAERI nuclear facilities, for fiscal 1996  

Energy Technology Data Exchange (ETDEWEB)

This issue is the collection of the papers on progress of researches by common utilization of JAERI nuclear facilities. The 43 of the papers are indexed individually. (J.P.N.)

1998-01-01

5

Therapeutic Applications of Monte Carlo Calculations in Nuclear Medicine  

CERN Document Server

This book examines the applications of Monte Carlo (MC) calculations in therapeutic nuclear medicine, from basic principles to computer implementations of software packages and their applications in radiation dosimetry and treatment planning. It is written for nuclear medicine physicists and physicians as well as radiation oncologists, and can serve as a supplementary text for medical imaging, radiation dosimetry and nuclear engineering graduate courses in science, medical and engineering faculties. With chapters is written by recognised authorities in that particular field, the book covers the entire range of MC applications in therapeutic medical and health physics, from its use in imaging prior to therapy to dose distribution modelling targeted radiotherapy. The contributions discuss the fundamental concepts of radiation dosimetry, radiobiological aspects of targeted radionuclide therapy and the ...

2003-01-01

6

Radiation technology, radiation technics and technological dosimetry in the Institute of Isotopes of the Hungarian Academy of Sciences. 1966-1981  

Energy Technology Data Exchange (ETDEWEB)

Pilot-plant irradiation began in Hungary in 1969 with the construction of a high-activity multi-purpose /sup 60/Co facility. Technologies for radiation sterilization, food handling, plastics irradiation as well as chemical dosimetry, semiconductor instrumental dosimetry, computer-based construction and control methods have been developed. Our chlorobenzene dose-meter system is used in Hungary and abroad; as a result of an IAEA-organized dosimetric intercomparison the system was adopted as a reference system. The institute has developed into a basic institute for the reconstruction and re-load of old ..gamma..-facilities as well as it serves for the planning, construction and launching of new ones in Hungary.

1982-01-01

7

Analytical studies of four-inch pipe whip tests under BWR LOCA conditions  

Energy Technology Data Exchange (ETDEWEB)

The purpose of pipe rupture studies in JAERI is to perform model tests on pipe whip, restraint behavior, jet impingement and jet thrust force, and to establish a computational method for analyzing these phenomena. This report presents the analytical results of 4-inch pipe whip tests under BWR LOCA conditions. Dynamic response analyses were performed using the general-purpose finite element program ADINA. The test pipe was modelled by straight beam elements and the four restraints were modelled by a single truss element. The analytical results were compared with the experimental results. Impact time and maximum total restraint force showed good agreement with experimental results. On the other hand, pipe strain and pipe deflection could not be predicted so well. The reason for this is that the sliding of the restraint during the pipe whip movement cannot be considered in the analyses.

1985-01-01

8

ISDD: A Computational Model of Particle Sedimentation, Diffusion and Target Cell Dosimetry for In Vitro Toxicity Studies  

Energy Technology Data Exchange (ETDEWEB)

Background: The difficulty of directly measuring cellular dose is a significant obstacle to application of target tissue dosimetry for nanoparticle and microparticle toxicity assessment. As a consequence, the target tissue paradigm for dosimetry and hazard assessment of nanoparticles has largely been ignored in favor of using metrics of exposure (e.g. ?g particle/mL culture medium, particle surface area/mL, particle number/mL). We have developed a computational model of solution particokinetics (sedimentation, diffusion) and dosimetry for non-interacting spherical particles and their agglomerates in monolayer cell culture systems. Particle transport to cells is calculated by simultaneous solution of Stokes Law (sedimentation) and the Stokes-Einstein equation (diffusion). Results: The In vitro Sedimentation, Diffusion and Dosimetry model (ISDD) was tested against measured transport ...

2010-11-30

9

The joint project for high-intensity proton accelerators  

Energy Technology Data Exchange (ETDEWEB)

Japan Atomic Energy Research Institute (JAERI) and the High Energy Accelerator Research Organization (KEK) are promoting the joint project integrating both the Neutron Science Project (NSP) of JAERI and the Japan Hadron Facility Project (JHF) of KEK for comprehensive studies on basic science and technology using high-intensity proton accelerator. This document describes the joint project prepared by the Joint Project Team of JAERI and KEK to construct accelerators and research facilities necessary both for the NSP and the JHF at the site of JAERI Tokai Establishment. It was originally written in English and translated into Japanese with some corrections. (author)

2000-02-01

10

INEEL Advanced Radiotherapy Research Program Annual Report for 2002  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the activities and major accomplishments for the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2002. Topics covered include computational dosimetry and treatment planning software development, medical neutron source development and characterization, and boron analytical chemistry.

2003-05-01

11

INEEL Advanced Radiotherapy Research Program Annual Report 2002  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the activities and major accomplishments for the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2002. Topics covered include computational dosimetry and treatment planning software development, medical neutron source development and characterization, and boron analytical chemistry.

2003-05-23

12

FY 1999 Laboratory Directed Research and Development annual report  

Energy Technology Data Exchange (ETDEWEB)

A short synopsis of each project is given covering the following main areas of research and development: Atmospheric sciences; Biotechnology; Chemical and instrumentation analysis; Computer and information science; Design and manufacture engineering; Ecological science; Electronics and sensors; Experimental technology; Health protection and dosimetry; Hydrologic and geologic science; Marine sciences; Materials science; Nuclear science and engineering; Process science and engineering; Sociotechnical systems analysis; Statistics and applied mathematics; and Thermal and energy systems.

2000-06-13

13

Clinical helical tomotherapy commissioning dosimetry  

International Nuclear Information System (INIS)

Helical tomotherapy presented many unique dosimetric challenges and solutions during the initial commissioning process, and some of them are presented. The dose calculation algorithm is convolution/superposition based. This requires that the energy fluence spectrum and magnitude be quantified. The methodology for doing so is described. Aspects of the energy fluence characterization that are unique to tomotherapy are highlighted. Many beam characteristics can be measured automatically by an included megavoltage computed tomography imaging system. This greatly improves data collection efficiency.

2003-12-01

14

On-line dosimetry for BNCT at the MIT research reactor  

Science.gov (United States)

A computer-based beam dosimetry measurement system for boron neutron capture therapy provides accurate, sensitive, and rapid readout and recording of all beam dose components, epithermal and thermal neutron flux, and gamma-ray dose rate. This dosimetric system includes input from the characterization of the epithermal neutron beam developed at the Massachusetts Institute of Technology, actual BPA pharmacokinetic data from a specific human subject being irradiated, output of MacNCTPLAN, a treatment planning system developed by the authors group, and input from the five on-line beam detectors. The purpose of this system and associated readout systems is to ensure that the desired dose is delivered to the subject within acceptable dose tolerances, e.g., {+-}5% of the target dose, and that any perturbations in the neutron beam that may occur during irradiation can be rapidly evaluated and the appropriate measures taken.

1996-12-31

15

On-line dosimetry for BNCT at the MIT research reactor  

International Nuclear Information System (INIS)

A computer-based beam dosimetry measurement system for boron neutron capture therapy provides accurate, sensitive, and rapid readout and recording of all beam dose components, epithermal and thermal neutron flux, and gamma-ray dose rate. This dosimetric system includes input from the characterization of the epithermal neutron beam developed at the Massachusetts Institute of Technology, actual BPA pharmacokinetic data from a specific human subject being irradiated, output of MacNCTPLAN, a treatment planning system developed by the authors group, and input from the five on-line beam detectors. The purpose of this system and associated readout systems is to ensure that the desired dose is delivered to the subject within acceptable dose tolerances, e.g., #+-#5% of the target dose, and that any perturbations in the neutron beam that may occur during irradiation can be rapidly evaluated and the appropriate measures taken.

1996-11-10

16

Development of a Bragg curve spectrometer (BCS) for fragment spectroscopy from neutron and proton induced reactions  

Energy Technology Data Exchange (ETDEWEB)

Energy and angular double differential cross-section data of fragments by tens of MeV neutron or proton are important to evaluate dosimetry and radiation effect in devices or instruments, since fragments cause a large local ionization. Up to now, experimental data of the fragment production are very scarce due to experimental difficulties of fragment detection. A bragg curve spectrometer (BCS) for fragment measurement is a gridded-ionization chamber that identify fragments on the basis of the difference of Bragg peak value. The BCS was fabricated to adopt for fragment measurement in neutron-induced reactions and tested with a charged-particle beam and then applied to a neutron field successfully. The structure of BCS is a cylindrical gridded ionization chamber, and filled with a Ar + 10% CH{sub 4} gas at a pressure of 2.7 x 10{sup 4} Pa. To confirm the performance of BCS, the following tests were performed: 1) the saturation property by using {sup 241}Am {alpha} ...

2002-09-01

17

A computer program for rapid calculation of internal committed effective dose through inhalation and ingestion pathways under radiological emergency  

International Nuclear Information System (INIS)

Objective: To establish a computer program for rapid calculation of internal committed effective close through inhalation and ingestion pathways under radiological emergency. Methods: Visual Basic 6.0 is used to compile the generic procedures of internal committed effective dose by inhalation and ingestion in IAEA-TECDOC-1162, Generic Procedures for Assessment and Response during a Radiological Emergency. Results: The assessment methodology of internal committed effective dose by inhalation and ingestion under radiological emergency in the report IAEA-TECDOC-1162 can be coded into a computer program. Conclusions: This research provides a rapid method of assessment for internal committed effective dose by inhalation and ingestion under radiological emergency, and it may provide needed dosimetry data for treatment under emergency response. (authors)

2008-08-01

18

Interest of a two-dimensional matrix of detectors for the quality control of beams in static or dynamic mode; Interet d'une matrice bidimensionnelle de detecteurs pour le controle de qualite des faisceaux en mode statique ou dynamique  

Energy Technology Data Exchange (ETDEWEB)

A 2D matrix allows a fairly rapid verification of irradiation parameters transferred on computer processing equipment without expanding the dosimetry means to implement. Associated to 'Multicheck and Verisoft' software it will handle some of the regulatory recommendations of the A.F.S.S.A.P.S. for quality control of accelerators and ensure the traceability of testing carried out. (N.C.)

2007-11-15

19

Algorithm for assessment of mean annual gonad dose and genetically significant dose from the data of personal dosimetry  

International Nuclear Information System (INIS)

During one year more than 40,000 items of information on radiation exposure of personnel involved in the handling of radiation sources and more than 5,000,000 items on irradiation of other people are collected in the authors' laboratory. Considerable progress in assessment of mean annual gonad dose of genetically sifnificant dose was attained by means of an algorithm for a personal computer. This simple and inexpensive system has led to a higher accuracy in the application of protective measures. (author).

1985-10-22

20

Dose verification using a pelvic phantom in high dose rate (HDR) brachytherapy  

Energy Technology Data Exchange (ETDEWEB)

High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom. In this study, the humanoid phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the humanoid phantom were then compared with the treatment planning system for the dose verification. The humanoid phantom needs to be designed such that the dose distributions can be quantitatively evaluated thermoluminescent dosimeter (TLD) chips with a dimension of 1/8 and film dosimetry with a spatial resolution of <1 mm used to measure the radiation ...

2003-07-01

21

Development of an efficient parallel FEM analysis program for large structural problems over several millions of DOF  

International Nuclear Information System (INIS)

In order to predict or to evaluate the structural reliability of a variety of nuclear components under actual changing operating conditions, it is necessary to take the detailed geometrical features of components into consideration on one hand, and thermo-mechanical loading conditions with space and time variations during the lifetime, on the other hand. This consideration leads the authors to develop a super large-scale structural analysis program based on a parallel computational FEM with a variable scale of PC cluster architecture, whose prototype system is presented in a companion paper in this Symposium. Development of the PC cluster technology is one of the most important subjects in large-scale structural simulation, reducing computer costs and thus making simulation more acceptable to the engineering community. This paper presents the developmental status of the parallel FEM solver, demonstrating computational ...

2000-09-01

22

JAERI TANDEM annual report 2000. April 1, 2000 - March 31, 2001  

Energy Technology Data Exchange (ETDEWEB)

This annual report describes research activities which have been performed with the JAERI tandem accelerator and the Van de Graaff accelerator from April 1, 2000 to March 31, 2001. Summary reports of 46 papers, and lists of publication, personnel and cooperative research with universities are contained. (author)

2001-11-01

23

MRI evaluation and image processing in gel dosimetry. A study of selected MRI properties and image processing in 3D gel dosimetry  

Energy Technology Data Exchange (ETDEWEB)

Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the background, were found to be the methods of choice. Pronounced MR image nonuniformity ...

2001-03-01

24

Proposal of the research complex for the neutron science (The first plan)  

Energy Technology Data Exchange (ETDEWEB)

Japan Atomic Energy Research Institute (JAERI) is developing the world`s strongest spallation neutron source using high power proton accelerator and promoting a neutron science project for comprehensive studies on basic science and nuclear transmutation of high-level radioactive nuclide from nuclear power stations. For this purpose, JAERI organized the Special Taskforce for Neutron Science and OMEGA Project in April 1996 and reorganized it to Center for Neutron Science in April 1997. During this period, various research plans using the spallation neutron source are proposed and facilities necessary for research are studied by mainly research groups of JAERI. This report describes research plans and results of the preliminary conceptual design study on proposed facilities plan. (author)

1999-03-01

25

Photon beam modelling with Pinnacle3 Treatment Planning System for a Rokus M Co-60 Machine  

International Nuclear Information System (INIS)

The basic relationships of the convolution/superposition dose calculation technique are reviewed, and a modelling technique that can be used for obtaining a satisfactory beam model for a commercially available convolution/superposition-based treatment planning system is described. A fluence energy spectrum for a Co-60 treatment machine obtained from a Monte Carlo simulation was used for modelling the fluence spectrum for a Rokus M machine. In order to achieve this model we measured the depth dose distribution and the dose profiles with a Wellhofer dosimetry system. The primary fluence was iteratively modelled by comparing the computed depth dose curves and beam profiles with the depth dose curves and crossbeam profiles measured in a water phantom. The objective of beam modelling is to build a model of the primary fluence that the patient is exposed to, which can then be used for the calculation of the dose deposited in the patient. (authors)

26

Computed tomography of the orbit  

Energy Technology Data Exchange (ETDEWEB)

In less than a decade computed tomography (CT scanning) had a profound impact on diagnostic radiology. Radiology of the orbit is no exception. As early as 1973, reports published in the radiological literature indicated that this new noninvasive imaging method was a highly effective way of demonstrating intraorbital mass lesions. As CT scanners became widely available, computed tomography became a significant adjunct to ophthalmological diagnosis. Today the main indications for CT scanning of the orbit are: (1) suspected mass lesions, most frequently presenting as exophthalmos, (2) orbital trauma, including foreign bodies, (3) some congenital anomalies, and (4) suspicion of extension into the orbit of extraorbital disease processes. Along with ultrasonography, another new noninvasive imaging technique, CT has replaced a number of more invasive and often less effective diagnostic methods, such as orbital pneumography, venography, and ...

1981-01-01

28

Development on the cryogenic hydrogen isotopes distillation process technology for tritium removal (Final report)  

Energy Technology Data Exchange (ETDEWEB)

While tritium exposure to the site-workers in Wolsung NPP is up to about 40% of the total personnel exposure, Ministry of Science and Technology has asked tritium removal facility for requirement of post heavy-water reactor construction. For the purpose of essential removal of tritium from the Wolsung heavy-water reactor system, a preliminary study on the cryogenic Ar-N{sub 2} and H{sub 2}-D{sub 2} distillation process for development of liquid-phase catalytic exchange cryogenic hydrogen distillation process technology. The Ar-N{sub 2} distillation column showed good performance with approximately 97% of final Ar concentration, and a computer simulation code was modified using these data. A simulation code developed for cryogenic hydrogen isotopes (H{sub 2}, HD, D{sub 2}, HT, DT, T{sub 2}) distillation column showed good performance after comparison with the result of a JAERI code, and a H{sub 2}-D{sub 2} distillation column was made. Gas ...

1995-12-01

30

Recent progress of the JAERI free electron laser driven by a compact superconducting RF linac  

International Nuclear Information System (INIS)

A prototype for a quasi-cw, and high-average power free electron laser (FEL) driven by a 15 MeV superconducting rf linac has been developed, and constructed at Tokai, JAERI since 1989. Cryogenic and accelerating fields' performances of four JAERI superconducting accelerator modules have been realized without any serious problem in the FEL accelerator vault and experimental hall. Since modification and related maintenance of the cryogenic refrigerator system for the driver were completed in the middle of October 1995, the system has run with no trouble, and the driver has been continuously run very successfully up to now. The optical resonator system and related electron beam transport system have been modified to realize larger acceptance than the old for both of the undulator radiation and energetic electron beam in 1995 Japanese fiscal year. In the modification, an alignment and distance measurement system has been newly developed, and ...

1997-02-28

31

Evaluating noncancer effects of trichloroethylene: dosimetry, mode of action, and risk assessment.  

UK PubMed Central (United Kingdom)

Alternatives for developing chronic exposure limits for noncancer effects of trichloroethylene (TCE) were evaluated. These alternatives were organized within a framework for dose-response assessment--exposure:dosimetry...Full Text Available

2000-05-01

33

Status of neutron cross sections for reactor dosimetry  

International Nuclear Information System (INIS)

The status of neutron activation cross sections for some threshold reactions important for reactor materials dosimetry is reviewed. An attempt is made to understand and explain discrepancies between integral and differential data, using recent available experimental results. The importance of standard and benchmark neutron fields for testing differential data for reactor dosimetry is emphasized and the Interlaboratory Reaction Rate (ILRR) program, as well as a similar program pursued by the IAEA, are briefly described.

1976-07-06

34

Hanford Internal Dosimetry Program Manual, PNL-MA-552  

Energy Technology Data Exchange (ETDEWEB)

This manual is a guide to the services provided by the Hanford Internal Dosimetry Program (IDP), which is operated by the Pacific Northwest National Laboratory.( ) for the U.S. Department of Energy Richland Operations Office, Office of River Protection and their Hanford Site contractors. The manual describes the roles of and relationships between the IDP and the radiation protection programs of the Hanford Site contractors. Recommendations and guidance are also provided for consideration in implementing bioassay monitoring and internal dosimetry elements of radiation protection programs.

2009-09-24

35

Deterministic calculations of radiation doses from brachytherapy seeds  

International Nuclear Information System (INIS)

Brachytherapy is used for treating certain types of cancer by inserting radioactive sources into tumours. CDTN/CNEN is developing brachytherapy seeds to be used mainly in prostate cancer treatment. Dose calculations play a very significant role in the characterization of the developed seeds. The current state-of-the-art of computation dosimetry relies on Monte Carlo methods using, for instance, MCNP codes. However, deterministic calculations have some advantages, as, for example, short computer time to find solutions. This paper presents a software developed to calculate doses in a two-dimensional space surrounding the seed, using a deterministic algorithm. The analysed seeds consist of capsules similar to IMC6711 (OncoSeed), that are commercially available. The exposure rates and absorbed doses are computed using the Sievert integral and the Meisberger third order polynomial, respectively. The software ...

2003-08-17

36

Review of scenario earthquake developing methods based on the PSHA results  

Energy Technology Data Exchange (ETDEWEB)

In this study, the two methods, US NRC and JAERI method, for the determination of scenario earthquakes for seismic design of nuclear power plants based on the probabilistic seismic hazard analysis were reviewed. The scenario earthquakes were developed for the Wolsung NPP site using the PSHA results based on the US NRC Regulatory Guide 1.165 procedures. It seems that the JAERI method is more appropriate to incorporate the effects of individual seismic sources and active faults, and to estimate the multiple ground motion parameters. The magnitude and distance bins of the scenario earthquakes for Wolsung NPP site were M6.4, 9km and M6.2, 13km.

2002-10-01

37

TLD array for precise dose measurements in stereotactic radiation techniques  

International Nuclear Information System (INIS)

We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and calculated data at full width at half maximum. ...

1996-12-01

38

Intensity-Modulated Radiation Therapy with Noncoplanar Beams for Treatment of Prostate Cancer in Patients with Bilateral Hip Prosthesis-A Case Study  

International Nuclear Information System (INIS)

Megavoltage photon intensity-modulated radiation therapy (IMRT) is typically used in the treatment of prostate cancer at our institution. Approximately 1% to 2% of patients with prostate cancer have hip prostheses. The presence of the prosthesis usually complicates the planning process because of dose perturbation around the prosthesis, radiation attenuation through the prosthesis, and the introduction of computed tomography artifacts in the planning volume. In addition, hip prostheses are typically made of materials of high atomic number, which add uncertainty to the dosimetry of the prostate and critical organs in the planning volume. When the prosthesis is bilateral, treatment planning is further complicated because only a limited number of beam angles can be used to avoid the prostheses. In this case study, we will report the observed advantages of using noncoplanar beams in the delivery of IMRT to a prostate cancer patient with bilateral ...

2010-01-01

39

Target R and D at JAERI  

Energy Technology Data Exchange (ETDEWEB)

We proposed a solid and a mercury target concepts through the preliminary conceptual design. To feasible these concepts, analysis and experimental works are being carried out. This paper introduces an outline of present status of target R and D such as heat transfer augmentation experiments for the solid target, mercury flow tests with a loop of maximum flow rate of 15L/min, flow pattern measurements for a cold source moderator etc. as well as preliminary conceptual design works. (author)

1999-03-01

40

Progress of JAERI neutron science project  

Energy Technology Data Exchange (ETDEWEB)

Neutron Science Project was started at Japan Atomic Energy Research Institute since 1996 for promoting futuristic basic science and nuclear technology utilizing neutrons. For this purpose, research and developments of intense proton accelerator and spallation neutron target were initiated. The present paper describes the current status of such research and developments. (author)

1999-03-01

41

Development of heavy-ion irradiation technique for single-event in semiconductor devices  

Energy Technology Data Exchange (ETDEWEB)

Heavy-ion irradiation technique has been developed for the evaluation of single-event effects on semiconductor devices. For the uniform irradiation of high energy heavy ions to device samples, we have designed and installed a magnetic beam-scanning system in a JAERI cyclotron beam course. It was found that scanned area was approximately 4 x 2 centimeters and that the deviation of ion fluence from the average value was less than 7%. (author)

1997-03-01

42

Analysis of the MEX-15 multipurpose reactor using SRAC code system  

Energy Technology Data Exchange (ETDEWEB)

The MEX-15 is a conceptual design of a Multipurpose Reactor with thermal power of 15 MW and this reactor is pool type with fuel plates U{sub 3}0{sub 8}-Al of low enrichment uranium. This report presents the static calculation for the MEX-15 reactor using SRAC code system and was developed under the collaboration agreement between ININ-JAERI in Research Reactor Technology Development Division of Department of Research Reactor in Tokai Research Establishment. (Author)

1992-12-15

43

Land And Water Use Characteristics And Human Health Input Parameters For Use In Environmental Dosimetry And Risk Assessments At The Savannah River Site  

International Nuclear Information System (INIS)

Operations at the Savannah River Site (SRS) result in releases of small amounts of radioactive materials to the atmosphere and to the Savannah River. For regulatory compliance purposes, potential offsite radiological doses are estimated annually using computer models that follow U.S. Nuclear Regulatory Commission (NRC) Regulatory Guides. Within the regulatory guides, default values are provided for many of the dose model parameters but the use of site-specific values by the applicant is encouraged. A detailed survey of land and water use parameters was conducted in 1991 and is being updated here. These parameters include local characteristics of meat, milk and vegetable production; river recreational activities; and meat, milk and vegetable consumption rates as well as other human usage parameters required in the SRS dosimetry models. In addition, the preferred elemental bioaccumulation factors and transfer factors to be used in human health ...

44

Computer Security and the Web  

CERN Multimedia

Computer Security and the Web

1997-01-01

45

VOLUME I11 IMISSION SYSTEM PERFORMANCE - NASA Technical Report ...  

Science.gov (United States)

Nov 8, 2010 ... Ihring Mission 11, the radiation dosimetry measurement system functioned normally and provided data on the Earth's trapped radiation belts ...

46

Luminescence dating of marine and fluvial sediments ... - GCMD - NASA  

Science.gov (United States)

INAA (instrumental neutron activation analysis) analyses have been made of subsamples of each OSL (Optically stimulated luminescence) sample, for dosimetry ...

47

Correlation between particle size, in vivo particle persistence, and lung injury.  

UK PubMed Central (United Kingdom)

Dosimetry parameters such as deposition, clearance, retention, and translocation and dissolution of inhaled particles in and to different lung compartments may be important for the persistence of particles...Full Text Available

1994-10-01

49

High extraction efficiency observed at the JAERI free-electron laser  

International Nuclear Information System (INIS)

A high power Free-Electron Laser (FEL) has lased at a wavelength of 22 #mu#m at the Japan Atomic Energy Research Institute (JAERI). The maximum power on a macro-pulse average is 1.7 kW, and it corresponds to an FEL energy of 160 #mu#J/micro-pulse. Extraction efficiency from the electron beam to the FEL radiation was measured to be 5.3% by an energy analyzer, when the maximum FEL power was coupled out. The rms wavelength spread was measured to be 4.6% at the same time. The extraction efficiency, in general, has a maximum value near the zero detuning length of an optical cavity, where (in contrast) the single-pass gain becomes smallest. A high peak current and a long macro-pulse duration are therefore indispensable for realizing high efficiency. The electron beam energy is 16.5 MeV, and the average current is 5.3 mA at a micro-pulse repetition rate of 10.4 MHz. The macro-pulse duration is 500 #mu#s (5000 micro-pulses), long enough to reach saturation near the zero ...

2001-12-21

50

Development of high power negative ion sources for fusion at JAERI  

Energy Technology Data Exchange (ETDEWEB)

Technologies producing high power negative ion beams have been highly developed in these years at JAERI for use in neutral beam injectors for heating the thermonuclear fusion plasmas. At present, it is possible to produce multi-ampere H-/D- ion beams quasi-continuously at energies more than a few hundred keV with a good beam optics of beamlet divergence of a few milli-radian. Based on these technologies, two R and D projects have been initiated; one is to develop a 22A/500keV/10s D- ion source for the neutral beam injector for JT-60U, and the other is to develop a 1A/1MeV/60s H- ion source to demonstrate high current negative ion acceleration up to the energy of 1MeV, the energy required for the neutral beam injector for International Thermonuclear Experimental Reactor (ITER). (author).

1995-10-01

51

Corrosion resistance of oxide scale formed on SiSiC in boiling sulfuric acid  

International Nuclear Information System (INIS)

SiSiC is one of selected materials for the thermal chemical hydrogen production IS (Iodine-Sulfur) process at JAERI. SiSiC was tested in boiling sulfuric acid for 1000 hours. The obtained results showed the following facts. The transverse strength was not changed by sulfuric corrosion, high temperature oxidation and oxidation. Silica scale formed on SiSiC by sulfate corrosion and high temperature oxidation had corrosion resistance in boiling sulfuric acid. Bilayer structure of silica scale produced by high temperature oxidation was not affected by sulfate corrosion. (S.Y.).

52

INTRINSIC DOSIMETRY: A POTENTIAL NEW TOOL FOR NUCLEAR FORENSICS INVESTIGATIONS  

International Nuclear Information System (INIS)

Thermoluminescence (TL) dosimetry was used to measure dose effects on the raw stock material of borosilicate container glass from different geographical locations. Effects were studied at times up to 60 days post-irradiation at doses from 0.15 to 20 Gy. The minimum detectable dose using this technique was estimated to be 0.15 Gy which is roughly equivalent to a 24 hr irradiation 1 cm from a 50 ng source of 60Co. Two peaks were identified in the TL glow curve, a relatively unstable peak around 125 C and a more stable peak around 225 C. Differences in TL glow curve shape and intensity were also observed for the glasses from different geographical origins. We investigate radiation induced defects in glass to further develop the technique of intrinsic dosimetry - the measurement of the total absorbed dose received by the walls of a container holding radioactive material. Intrinsic dosimetry is intended to be used as an ...

2010-07-11

53

Semi-empirical simulation of thermoluminescent response under different filter geometries; Simulacao semi-empirica da resposta termoluminescente sob diferentes geometrias de filtro  

Energy Technology Data Exchange (ETDEWEB)

Many thermoluminescent materials has been developed and used for photon personal dosimetry but no one has all desired characteristics alone. These characteristics include robustness, high sensitivity, energy photon independence, large range of photon energy detection, good reproducibility, small fading and simple glow curve with peaks above 150 deg C. Calcium Sulfate Dysprosium doped (CaSO{sub 4}:Dy) phosphor Thermoluminescent Dosimeter (TLD) has been used by many laboratories, mainly in Brazil and India. Another interesting phosphor is Calcium Fluoride (CaF{sub 2}). These phosphor advantages begin to be more required and its disadvantages have became more apparent, in a global market more and more competitive. These phosphors are used in environmental and area monitoring, once they present more sensibility than other phosphors, like LiF:Mg. Theirs mainly disadvantage is a strong energetic dependence response, which must be corrected for theirs application in the ...

2006-07-01

54

Radon in soil gas survey in Curitiba (Brazil)  

International Nuclear Information System (INIS)

This work describes the radon in soil gas measurements performed during the last two years in cooperation between the Laboratory of Applied Nuclear Physics of the Federal University of Technology (UTFPR), the Nuclear Technology Development Center (CDTN) and the Institute of Radiation Protection and Dosimetry (IRD) from the Brazilian Nuclear Energy Commission (CNEN). Following previously concluded measurements of radon concentration in dwellings and the measurements of 222Rn activity in drinking water collected at artesian bores of Curitiba urban area, present step of activities has been dedicated to measurements of radon concentration in soil gas. Experimental setup was based on the Professional Radon Monitor (ALPHA GUARD) connected to specially developed for such measurements Soil Gas Probe through the air pump and filter system. After the Probe was inserted, the ground has been tamped down around the probe, to prevent air from moving vertically along the outside ...

2002-10-08

55

Radiation dosimetry of "1"1"1In-oxinate labelled leucocytes  

International Nuclear Information System (INIS)

The patients studied were referred for routine abscess localization with indium-111 labelled autologous leukocytes. One series (n=15) was studied at 1 day after reinjection of labelled cells and a second series (n=9) was studied between 4 hours and 4 days after reinjection of labelled cells. The leukocytes were isolated by a gravity sedimentation method and labelled with In-111 oxinate according to Roevekamp and co-workers. The labelled cell suspension administered to the patient contained between 11 and 15 MegaBq (300-400 microCi). The indium-111 concentration in the liver and spleen was quantitated using a scintillation camera and an on-line computer system. Phantom studies were carried out to obtain conversion factors from geometric mean counts to MegaBq of activity for both liver and spleen. Once determined, the amount of activity in liver and spleen was corrected for physical decay of In-111 and expressed as a percentage of the administered activity. ...

1982-06-25

56

Performance of Brazilian thermoluminescent CaSO{sub 4}: Dy pellets in standard diagnostic radiology beams  

Energy Technology Data Exchange (ETDEWEB)

The high sensitivity of CaSO{sub 4}: Dy as a thermoluminescent material is a great advantage when dealing with low dose levels, as in diagnostic radiology procedures. However, these kinds of dosemeters present a high energy dependence that must be precisely determined in the energy range of interest. Dosimetric pellets of CaSO{sub 4}: Dy are produced at IPEN since the end of the 80 Th decade. These pellets are produced in three forms: conventional CaSO{sub 4}: Dy (50 mg); thin CaSO{sub 4}: Dy (20 mg) and CaSO{sub 4}: Dy + 10% C (20 mg). The main applications of these dosemeters are in personal and environmental dosimetry. In this study, CaSO{sub 4}: Dy pellets produced at IPEN were evaluated in diagnostic radiology standard beams. These qualities are based on the IEC 61267 standard, and they were established at an industrial X-ray system Pantak/Seifert, model ISOVOLT 160HS. Former studies evaluated CaSO{sub 4}: Dy of different origins in diagnostic beams. In this ...

2006-07-01

57

Neutron induced reaction cross-sections of iron in the energy range 1 to 20 MeV: A work programme  

International Nuclear Information System (INIS)

Iron is one of the main constituents of stainless steel which is used as a structural material in nuclear reactors. In fast and conceptual fusion and fusion-fission hybrid systems the primary energy range of neutron interaction lies between 1 and 20 MeV which opens up several reaction channels. The reaction cross-sections in this energy range are important for dosimetry, radiation damage, neutronics and safety studies of nuclear reactors. Keeping this in view Nuclear Data Section of the International Atomic Energy Agency has sponsored a Research Co-ordination Programme on Methods for the Calculation of Fast Neutron Nuclear Data for Structural Elements. Under this programme we propose to study (n,n'), (n,2n), (n,3n), (n,p), (n,np), (n,pn), (n,#alpha#), (n,n#alpha#), (n,#alpha#n) and (n,#gamma#) reaction cross-sections. Besides these, total, elastic and discrete level inelastic scattering cross-sections, angular distributions of neutron production cross-sections, ...

1988-01-01

58

Personal nuclear accident dosimetry at Sandia National Laboratories  

Energy Technology Data Exchange (ETDEWEB)

DOE installations possessing sufficient quantities of fissile material to potentially constitute a critical mass, such that the excessive exposure of personnel to radiation from a nuclear accident is possible, are required to provide nuclear accident dosimetry services. This document describes the personal nuclear accident dosimeter (PNAD) used by SNL and prescribes methodologies to initially screen, and to process PNAD results. In addition, this report describes PNAD dosimetry results obtained during the Nuclear Accident Dosimeter Intercomparison Study (NAD23), held during 12-16 June 1995, at Los Alamos National Laboratories. Biases for reported neutron doses ranged from -6% to +36% with an average bias of +12%.

1996-09-01

59

TLD assessment of mouse dosimetry during microCT imaging  

UK PubMed Central (United Kingdom)

Advances in laboratory animal imaging have provided new resources for noninvasive biomedical research. Among these technologies is microcomputed tomography (microCT) which is widely used to obtain high...Full Text Available

2008-09-01

60

Studies of neutron dosimetry  

Energy Technology Data Exchange (ETDEWEB)

A high-purity, intense, fast-neutron source has been developed at our laboratory. We describe two inexpensive, straightforward methods of determining the total number of neutrons produced and we review precautions to be taken in applying these methods. (orig.).

1997-04-01

61

Revised neutron dosimetry results for the MOTA-2A experiment in FFTF  

Energy Technology Data Exchange (ETDEWEB)

Revised neutron fluence and damage values are reported for the MOTA-2A experiment in the Fast Flux Test Facility (FFTF). This revision corrects an error with processing of the {sup 235}U(n,f) reaction. Net corrections are on the order of 5%.

1994-09-01

62

Project resumes: biological effects from electric fields associated with high-voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Abstracts of research projects are presented in the following areas: measurements and special facilities; cellular and subcellular studies; physiology; behavior; environmental effects; modeling, scaling and dosimetry; and high voltage direct current. (ACR)

1980-01-01

63

Photon dosimetry using plastic scintillators in pulsed radiation fields  

Energy Technology Data Exchange (ETDEWEB)

Simulations and experiments have been carried out to explore using a plastic scintillator as a dosimetry probe in the vicinity of a pulsed bremsstrahlung source in the range 4 to 20 MeV. Taking advantage of the tissue-equivalent properties of this detector in conjunction with the use of a fast digital signal processor near real-time dosimetry was shown to be possible. The importance of accounting for a broad energy electron beam in bremsstrahlung production, and photon scattering and build-up, in correctly interpreting dosimetry results at long stand-off distances is highlighted by comparing real world experiments with ideal geometry simulations. Close agreement was found between absorbed energy calculations based upon spectroscopic techniques and calculations based upon signal integration, showing a ratio between 10 MeV absorbed dose to 12 MeV absorbed dose of 0.66 at a distance of 91.4 m from the accelerator. This is ...

2007-04-01

64

Final Report of the 2nd Ex-Vessel Neutron Dosimetry Installation And Evaluations for Kori Unit 3 Reactor Pressure Vessel  

International Nuclear Information System (INIS)

This report describes a neutron fluence assessment performed for the Kori Unit 3 pressure vessel beltline region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the beltline region of the pressure vessel. After Cycle 16 of reactor operation, 2nd Ex-Vessel Neutron Dosimetry Program was instituted at Kori Unit 3 to provide continuous monitoring of the beltline region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 17

2006-06-13

65

EPR dosimetry in chemically treated fingernails  

UK PubMed Central (United Kingdom)

By using EPR measurements of radiation-induced radicals it is possible to utilize human fingernails to estimate radiation dose after-the-fact. One of the potentially limiting factors in this...Full Text Available

2007-08-01

66

Assessment of nodal target definition and dosimetry using three different techniques: implications for re-defining the optimal pelvic field in endometrial cancer  

UK PubMed Central (United Kingdom)

Purposes1. To determine the optimal pelvic nodal clinical target volume for post-operative treatment of endometrial cancer. 2. To compare the DVH of different treatment planning...Full Text Available

67

1,3-Butadiene: linking metabolism, dosimetry, and mutation induction.  

UK PubMed Central (United Kingdom)

There is increasing concern for the potential adverse health effects of human exposures to chemical mixtures. To better understand the complex interactions of chemicals within a mixture, it is essential...Full Text Available

1994-11-01

68

Tritium bioassay and dosimetry at a CANDU reactors  

Energy Technology Data Exchange (ETDEWEB)

Tritium dose management is an important aspect of the radiation protection program at CANDU type reactor sites. This paper describes the bioassay and dosimetry of tritium at CANDU reactor sites, especially for Wolsung Nuclear Power Plant. It presents a compilation of information drawn from published papers, technical reports, international and national guidelines as well as practical experience both in Korean and Canadian CANDU Nuclear Power Plants. The implementation of this program would provide a technical basis for calculations and records should be of acceptable quality and should meet overall radiation protection program objectives.

1996-07-01

69

Passive dosimetry of radon and its daughters using solid state nuclear track detectors (SSNTDs)  

Energy Technology Data Exchange (ETDEWEB)

Indoor radon is a potential health hazard for the general public, especially in buildings with poor ventilation. A variety of dosemeters have been developed and used in surveys of radon concentration measurements. In this article the passive dosemeters which are based on solid state nuclear track detectors are reviewed. The principle of passive dosimetry and the factors affecting their performance are discussed. The characteristics of SSNTD materials in relation to their behaviour under different environmental conditions are tabulated and discussed. Results of radon surveys from selected studies are also presented. (Author).

1993-01-01

70

NRC safety research priorities for reactor vessel embrittlement, annealing, and surveillance dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The recent definition of a postulated thermal shock accident followed promptly by system repressurization, termed an overcooling or pressurized thermal shock accident, has set a large analysis and research effort into motion. The essential elements are concerned with defining the accident transients, evaluating the instrumentation and controls that cause the postulated accidents, and evaluating the metallurgical and structural mechanics aspects of the reactor vessel with respect to its failure potential. This paper poses the question faced by the Nuclear Regulatory Commission (NRC) for the vessel steel embrittlement, annealing, and surveillance dosimetry facets of this postulated accident and provides information on our plans for study of this problem as well as current status.

1981-10-01

71

Multicellular level dosimetry and low dose rate effects  

International Nuclear Information System (INIS)

Building on the concepts of MIRD methods described by Webber, Watson and others at this Symposium on the Dosimetry of Administered Radionuclides, we will now consider how to apply these principles to several experimentally based open-quote macroclose quotes and multicellular models. Specifically, methods to calculate absorbed dose using different types of particulate emission (alpha, beta) with a variety of antibody carriers (IgG, F(ab')_2, Fab) for radioimmunotherapy (RIT) will be reviewed. Additionally, a discussion of direct measurement methods at the multicellular level will reveal the problems of tumor absorbed dose heterogeneity when applied to animal and clinical studies.

1989-09-21

72

Dual-field rotational (DFR) technique for total-skin electron-beam therapy (TSEBT)  

Energy Technology Data Exchange (ETDEWEB)

Comparison of dosimetry measured in a noncylindrical Rando-Alderson phantom by two-field, four-field, and six-field total-skin electron-beam therapy (TSEBT) techniques with our dual-field rotational (DFR) technique reveals a superior dosimetry for the latter. Our technique of dual-field rotational DFR-TSEBT is described in detail, and its advantages and indications for the primary management of cutaneous T-cell lymphoma (CTCL) and Kaposi's sarcoma (KS) are discussed.

1987-08-01

73

Conception, realization and test of an electronic Si-LiF-Si sensor for neutron spectrometry and dosimetry  

International Nuclear Information System (INIS)

The aim of this thesis is the study of new systems devoted to the real time neutron spectrometry and dosimetry. The microelectronics technologies have been used to research a micro system integrating sensor and data processing in real time. The multi range sensor is based on many pair of semiconductor diodes placed face to face and covered by lithium fluoride. The sensor has been designed and its behavior has been simulated. Its operating in reference neutrons beams has been analyzed. (A.L.B.)

1998-01-01

74

Particle identification for heavy ions in a time-of-flight spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A time-of-flight (TOF) spectrometer has been constructed at the JAERI 20 MV tandem accelerator facility. A position-sensitive start detector, which consists of a thin carbon foil, microchannel plates and a resistive plate, was developed for the TOF measurements through the spectrometer. The time and position resolutions obtained were 120 ps and 0.3 mm for ..cap alpha.. particles from /sup 241/Am, respectively. A two-dimensional position-sensitive detector was also developed to measure the solid angle of the spectrometer and the maximum solid angle obtained was 9.5 msr. As a particle detector a Bragg curve ionization chamber was developed. From the Bragg curves of heavy ions in the detector, energies, ranges and Bragg curve peaks were measured and used for particle identification. The resolving power Z/..delta..Z of the atomic number was about 50.

1982-05-01

75

Experimental and analytical studies of pipe whip tests under PWR LOCA conditions  

Energy Technology Data Exchange (ETDEWEB)

A series of pipe rupture tests has been performed at JAERI to demonstrate the safety of primary coolant circuits in the event of pipe rupture in nuclear power plants. Pipe whip tests and jet discharge tests have been conducted under BWR and PWR loss-of-coolant accident (LOCA) conditions. The present paper describes the experimental and analytical results of the pipe whip tests performed under PWR LOCA conditions using 4, 6 and 8-inch test pipes. The tests were carried out at an initial pressure and temperature of 15.7 MPa and 325/sup 0/C, respectively. Moreover, a dynamic analysis of pipe whip tests was carried out using the general purpose finite element programm ADINA.

1987-09-01

76

Decontamination factor of an incinerator for radioactive solid wastes  

International Nuclear Information System (INIS)

An incinerator for the treatment of low-level radioactive solid wastes was installed in Tokai Research Establishment, JAERI, 1966. The incinerator was equipped with a scrubber, cyclone, electrostatic precipitator and HEPA filter. The retention factor (R.F.) of the furnace as well as the decontamination factors (D.F.) of each dust collector were measured using "3"2P as a tracer under various conditions. It was found that the overall D.F. of the incinerator was improved by the increase of the temperature in the furnace, decrease of the off gas flowrate, increase of the charged voltage of the electrostatic precipitator and by the increase of the liquid gas ratio of the scrubber. The overall D.F. of the incinerator (including the R.F. in the furnace) on the standard operating conditions was 9.1x10"6. (auth.).

77

(International Panel on 14 MeV Intense Neutron Source Based on Accelerators for Fusion Materials Study)  

Energy Technology Data Exchange (ETDEWEB)

Both travelers were members of a nine-person US delegation that participated in an international workshop on accelerator-based 14 MeV neutron sources for fusion materials research hosted by the University of Tokyo. Presentations made at the workshop reviewed the technology developed by the FMIT Project, advances in accelerator technology, and proposed concepts for neutron sources. One traveler then participated in the initial meeting of the IEA Working Group on High Energy, High Flux Neutron Sources in which efforts were begun to evaluate and compare proposed neutron sources; the Fourth FFTF/MOTA Experimenters' Workshop which covered planning and coordination of the US-Japan collaboration using the FFTF reactor to irradiate fusion reactor materials; and held discussions with several JAERI personnel on the US-Japan collaboration on fusion reactor materials.

1991-02-14

78

Proposal of procedures to prevent errors in radiotherapy based in learned lessons of accidental expositions; Proposta de procedimentos para evitar erros em radioterapia baseados em licoes aprendidas de exposicoes acidentais  

Energy Technology Data Exchange (ETDEWEB)

In order to consider some procedures to prevent errors in radiotherapy based in learned lessons of accidental expositions and in accordance with information contained in international reports elaborated by International Atomic Energy Agency (IAEA) and of the data base availability by the European group Radiation Oncology Safety Information System (ROSIS) on the events, a research of the occurred errors was performed. For the evaluation of the incidents a data base based in the ROSIS and added plus a parameter was created 'type of error'. All the stored data make possible the evaluation of the 839 incidents in terms of frequency of the type of error, the process of detention, the number of reached patients and the degree of severity. Of the 50 types of found errors, the type of error more frequently was 'incorrect treatment coordinate', confirmed with the data of literature and representing 28,96 por cent of the total of the incidents. The results ...

2007-07-01

79

Present status of study on reduced-moderation water reactors  

Energy Technology Data Exchange (ETDEWEB)

The Reduced-Moderation Water Reactor (RMWR) is a next generation water-cooled reactor, based on the experienced light water reactor (LWR) technology, aiming at effective utilization of uranium resources, high burn-up and long operation cycle and plutonium multiple recycling. These characteristics can be achieved by the high conversion ratio from {sup 238}U to {sup 239}Pu resulted from the higher neutron energy spectrum in comparison to conventional LWRs. Considering the extension of LWR utilization, Japan Atomic Energy Research Institute (JAERI) started the research on it in 1997 and then started a collaboration in the conceptual design study with the Japan Atomic Power Company (JAPC) in 1998, under technical cooperation with three Japanese reactor vendors. In the core design study of the RMWR, several basic core designs with the high conversion ratio more than 1 and the negative void reactivity coefficient have been proposed, and then, subsequent investigation on ...

2001-09-01

80

Evaluation of critical heat flux of tight lattice core with subchannel analysis code NASCA  

International Nuclear Information System (INIS)

Reduced-Moderation Water reactor (RMWR) is a light water breeder reactor developed by Japan Atomic Energy Research Institute (JAERI). The RMWR comprises tight lattice fuel assemblies with gap clearance of around 1.0 mm to reduce water volume ratio to achieve a high conversion ratio. It is important to estimate the thermal hydraulic safety margin of the tight lattice core of the RMWR. In the present study, the boiling transition (BT) prediction performance of the subchannel analysis code NASCA developed for the current BWR cores was assessed for series of tight lattice critical heat flux (CHF) experiments performed in JAERI. The test section was a 7-rod bundle with rod diameter of 12.3 mm, rod gap of 1.0 mm and heated length of 1.8m. Axial power distribution was flat. With a simple subchannel model, the code overestimates the critical power in the high mass velocity region, although the predicted critical powers in the low mass velocity region ...

2003-04-20

81

Retrospective individual dosimetry using luminescence and EPR after radiation accidents  

International Nuclear Information System (INIS)

In areas where radiation dose monitoring has not been performed, it is essential to use material available in the environment be able to rapidly assess doses to individuals for immediate emergency medical care or for general estimation of the radiological consequences. It was shown that certain types of telephone cards containing microchips have the potential to be used as individual radiation dosimeters in emergency situations to detect doses over 250 mGy by luminescence measurements. In order to understand the dosimetric properties of chip cards, the components obtained from INFINIEON Company at various stages of production were used for luminescence measurements. It is found that the protecting layer used above the chips so called 'globe top' is the main source of radiation induced signal in chip cards. The globe top produced by INFINIEON at that stage is found to contain SiO2 and Epoxy. In order to improve the dosimetric properties of the chip cards, the raw material of the globe ...

82

The result of Alanine/ESR dosimetry at Wolsung unit 1  

International Nuclear Information System (INIS)

It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate dose, two environmental correction factors, irradiation temperature and ...

2008-10-01

83

ESR/Alanine dosimetry on Wolsung Unit 1  

Energy Technology Data Exchange (ETDEWEB)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level ...

2007-07-01

84

ESR/Alanine dosimetry on Wolsung Unit 1  

International Nuclear Information System (INIS)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level ...

2007-05-10

85

Calibration methods of plane-parallel ionization chambers used in electron dosimetry; Metodos de calibracao de camaras de ionizacao de placas paralelas para dosimetria de feixes de eletrons  

Energy Technology Data Exchange (ETDEWEB)

The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionization chambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionization chambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration certificate and data sheets are presented. (author)

1999-07-01

86

Possible Computer Vision Systems and Automated or Computer-Aided ...  

Science.gov (United States)

Jun 16, 2011 ... The research is part of a team effort to help the hardwood sawmill industry automate with computer vision systems, and computer-aided or ...

88

Thermoluminescent (Tl) dosimetry of slow-neutron fields at radiotherapy dose level  

Energy Technology Data Exchange (ETDEWEB)

The dosimetry for radiotherapy involving neutrons is very complicated, owing to the complexity of secondary radiation components, whose contributions to the total absorbed dose have to be discriminated, owing to the different radiobiological effects. In order to separate thermal neutrons and photons, LiF dosimeters are mostly utilized. containing different percentage of Li, like as TLD-700, TLD-100 and TLD-600, but many problems arise. In the response of TLD-700 exposed to neutron-gamma mixed fields with high neutron flux, the contribution of thermal neutrons to the Tl emission is high. Moreover. TLD-100 and TLD-600 may undergo radiation damage, and great care has to be taken in order to obtain reliable results. Other TLDs showing lower sensitivity to neutrons are proposed and experimented for such high-flux neutron fields. The faced problems and various proposed solutions are here described. (Author)

2003-07-01

89

Preparation and dosimetry of radiotherapeutic particles for arthropaties; Preparacion y dosimetria de particulas radioterapeuticas para artropatias  

Energy Technology Data Exchange (ETDEWEB)

It was developed a new formulation of macro aggregates of Samarium 153 ({sup 153} Sm-MH) for the arthropaties treatment. The radio pharmaceutic was prepared by reaction of Samarium 153 chloride (SmCl{sub 3}) in aqueous environment with sodium boron hydride in NaOH 0.5 N. The microscopic analysis shown that the particles have an average size of 4% m (range 1-14 {mu} m). The velocity of sedimentation was 0.008 cm/min with high stability in vitro in human serum. The biological studies in healthy rabbits, shown that the complex is retained inside the articulation still eight days after of the administration of the radiopharmaceutical. Likewise, it is presented the data of absorbed dose in the different target organs, which was determined by thermoluminescent dosimetry (TLD) through the use of a REMCAL phantom (radiation equivalent manikin calibration). (Author)

1999-07-01

90

Intraoperative radiation therapy at the National Cancer Institute: technical innovations and dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The technical complexity of intraoperative radiotherapy (IORT) requires modification of the standard physical and dosimetric methods used in external electron beam therapy. At the National Cancer Institute, a number of technical innovations have been integrated into ongoing clinical studies of IORT. These include: (1) an electron beam applicator system that is significantly different from other IORT systems and includes customized squircle applicators; (2) peripheral dose shields; (3) a modified surgical table replacing the standard radiation treatment couch; and (4) routine use of multiple IORT fields that necessitates field matching. The IORT applicator system and related devices and techniques are dosimetrically characterized in detail both for use in the IORT program and in order to illustrate many useful facets of electron dosimetry.

1985-07-01

91

Dosimetric considerations for patients with HIP prostheses undergoing pelvic irradiation. Report of the AAPM Radiation Therapy Committee Task Group 63  

International Nuclear Information System (INIS)

This document is the report of a task group of the Radiation Therapy Committee of the AAPM and has been prepared primarily to advise hospital physicists involved in external beam treatment of patients with pelvic malignancies who have high atomic number (Z) hip prostheses. The purpose of the report is to make the radiation oncology community aware of the problems arising from the presence of these devices in the radiation beam, to quantify the dose perturbations they cause, and, finally, to provide recommendations for treatment planning and delivery. Some of the data and recommendations are also applicable to patients having implanted high-Z prosthetic devices such as pins, humeral head replacements. The scientific understanding and methodology of clinical dosimetry for these situations is still incomplete. This report is intended to reflect the current state of scientific understanding and technical methodology in clinical dosimetry for ...

2003-06-01

92

Dose dependence of semiconductor material conductivity as a means of high fluence dosimetry  

Energy Technology Data Exchange (ETDEWEB)

Dose dependences of conductivity at a temperature of 78 K for InSb and InAs single crystals under reactor fast neutron, 50 MeV proton and 80 MeV alpha particle irradiation up to fluence of 10{sup 17} cm{sup -2} are considered. Special attention is given to non-trivial, but little known semi-conductor characteristics in terms of {sigma}(F) dependence at large fluences, and also to the versatility of such dependence for all semiconductors. The behaviour of semiconductor materials conductivity dependence on fluence presented here may be used for semiconductor dosemeters characterisitic variation forecasting under large fluence measurements and in radiation emergency dosimetry. (author).

1996-12-31

93

A TLD powder dosimetry measurement system for physical models of reference man  

International Nuclear Information System (INIS)

A tissue-equivalent dosimetry system has been developed for use in absorbed dose determinations with physical models of Reference Man. The dosimeter used was a thermo-luminescent dosimeter (TLD) powder which was mixed with a 'tissue-equivalent' material and modeled to closely approximate an organ's geometry and absorption properties. A separation procedure was developed by which the TLD powder was washed and the 'tissue-equivalent' material, a wax, was dissolved and extracted following the irradiation of the model. The procedure was tested to determine losses of powder, homogeneity of the powder's distribution throughout the wax, the effects of the separation procedure upon the powder and the statistical behavior of the procedure. The results of these tests established the feasibility of the procedure. A full-scale model of the pancreas was tested and the results supported the validity of the technique. (author)

1978-12-01

94

Computer based training cost-benefit model  

Energy Technology Data Exchange (ETDEWEB)

The costs of establishing a computer-based training program for FFTF reactor operators are analyzed.

1984-01-01

95

Improvement of a high-resolution pulse cold neutron spectrometer AGNES  

International Nuclear Information System (INIS)

AGNES is a chopper spectrometer installed at the top of the C3 cold guide of JRR-3 (JAERI, Tokai). In 2004 - 2006, this spectrometer was greatly improved by installing (1) 208 new detectors to make the detector bank complete, (2) new radiation shields composed of Fe (14 mm), polyethylene (50 mm), B4C rubber (10 mm), and Cd (0.5 mm) sheets, (3) a new control system for the anti-frame-overlap chopper rotating simultaneously with the Fermi chopper, (4) a monitor counter at the space between the chopper and monochromator, (5) a neutron guide tube (50 cm) before the monochromator, (6) a new instrument control (monochromators, choppers, beam narrowers, etc.) and measurement control (real-time data monitoring, sample temperature control, etc.) systems, (7) a top-loading type cryostat workable at a wide temperature range of 6 - 480 K. As the results of these improvements, the signal intensity has been increased by 3.3 and the background has been reduced by 1/10 both ...

2007-01-01

96

Free-electron laser beam  

International Nuclear Information System (INIS)

The principle and history of free-electron laser (FEL), first evidenced in 1977, the relationship between FEL wavelength and output power, the high-power FEL driven by the superconducting linac, the X-ray FEL by the linac, and the medical use are described. FEL is the vacuum oscillator tube and essentially composed from the high-energy linac, undulator and light-resonator. It utilizes free electrons in the vacuum to generate the beam with wavelength ranging from microwave to gamma ray. The first high-power FEL developed in Japanese Atomic Energy Research Institute (JAERI) is based on the development of superconducting linac for oscillating the highest power beam. In the medical field, applications to excise brain tumors (in US) and to reconstruct experimentally blood vessels in the pig heart (in Gunma University) by lasing and laser coagulator are in progress with examinations to remove intra-vascular cholesterol mass by irradiation of 5.7#mu#m FEL beam. Cancer ...

2003-06-01

97

Design experience of the JRR-2 BNCT facility in JAERI  

Energy Technology Data Exchange (ETDEWEB)

The thermal neutron column of the JRR-2 reactor was remodelled in order to install a medical irradiation facility. The design experience and the cource of this remodelling are presented. At first, the thermal neutron flux was lower than expected, and the expected radiation condition was achieved by the following improvements: (1) removal of graphite from the thermal neutron column to increase the neutron flux, (2) twice increase of bismuth shielding and the shift of its position to improve the shielding effect against gamma ray, (3) application of B{sub 4}C rubber on the both surfaces of the shielding door to suppress the secondary gamma ray generation from the structural materials, (4) LiF tiles are applied on the inner face of the neutron beam exit hole to suppress the secondary gamma ray from the beam exit, and (5) installment a cone-shape polyethylene collimator to relieve the decay of thermal neutron. After the improvements, medical irradiation treatments have been performed ...

1994-06-01

98

Data report of BWR post-CHF tests. Transient core thermal-hydraulic test program. Contract research  

Energy Technology Data Exchange (ETDEWEB)

JAERI has been performing transient core thermal-hydraulic test program. In the program, authors performed BWR/ABWR DBE simulation tests with a test facility, which can simulate BWR/ABWR transients. The test facility has a 4 x 4 bundle core simulator with 15-rod heaters and one non-heated rod. Through the tests, authors quantified the thermal safety margin for core cooling. In order to quantify the thermal safety margin, authors collected experimental data on post-CHF. The data are essential for the evaluation of clad temperature transient when core heat-up occurs during DBEs. In comparison with previous post-CHF tests, present experiments were performed in much wider experimental condition, covering high clad temperature, low to high pressure and low to high mass flux. Further, data at wider elevation (lower to higher elevation of core) were obtained in the present experiments, which make possible to discuss the effect of axial position on thermal-hydraulics, ...

2001-03-01

99

Radiation doses and somatic risk to patients during cardiac radiological procedures  

International Nuclear Information System (INIS)

The radiation dose to a series of adult and paediatric patients undergoing cardiac catheterisations and adults having percutaneous transluminal coronary angioplasty has been measured/determined directly using lithium fluoride thermoluminescent dosemeters and indirectly using an air ionisation chamber which indicated exposure-area product. Somatic and genetic risks are estimated from the dosimetry results. It is suggested that the magnitude of the radiation hazard is negligible compared with other clinical hazards associated with these procedures. (author).

1986-01-01

100

Radiation Dosimetry considerations in the safe administration of therapeutic radiopharmaceuticals  

Energy Technology Data Exchange (ETDEWEB)

A set of eight questions was put to advanced nuclear medicine physicians-in-training participating in a continuing assessment exercise in practical therapeutic nuclear oncology. Using the particular example of {sup 131}I-MIBG treatment of neuroblastoma in children, the questions were directed to the rationale of therapy and the contribution of other forms of treatment to toxic effects. The best answer to the questions are reproduced together with an introduction by the examiner, Dr. H. Turner. tabs.

1995-12-01

101

Optical Fiber Sensors from Laboratory to Field Trials: Applications and Trends at CEA LIST  

British Library Electronic Table of Contents (United Kingdom)

Fiber optic metrology developed at the CEA LIST laboratories involves fiber Bragg grating sensors, distributed Brillouin optical time domain reflectometry and optically stimulated luminescence dosimetry. Recent activities in optical fiber sensing are reviewed from laboratory experiments to field trials.

2009-01-01

102

Intrinsic Dosimetry Of Glass Containers Used To Transport Nuclear Materials: Potential Implications to the Field of Nuclear Forensics  

International Nuclear Information System (INIS)

Thermoluminescence (TL) and Electron Paramagnetic Resonance (EPR) dosimetry were used to measure dose effects in borosilicate glass with time, from 10 minutes to #approx#60 days following exposure to a dose of up to 10,000 Rad. TL and EPR results were consistent and performed similarly, with both techniques capable of achieving an estimated limit of detection of between 50-100 Rad. Three peaks were identified in the TL glow curve at roughly 110 C, 205 C, and 225 C. The intensity of the 205 C peak was the dominant peak over the time period of this study. The stability of all of the peaks with time since irradiation increased with their corresponding temperature and little or no variation was observed in the glow curve response to a specified total dose attained at different dose rates. The intensity of the 205 C peak decreased logarithmically with time regardless of total dose. Based upon a conservative limit of detection of 330 Rad, a 10,000 Rad dose would still be ...

103

Influencing factors on ESR dose assessment in irradiated chicken legs  

Energy Technology Data Exchange (ETDEWEB)

Electron spin resonance (ESR) dosimetry of irradiated chicken legs is based on the additive dose or the calibration curve methods. In both cases the practical assumption is made that the behaviour of the chicken bone does not depend on factors such as temperature during irradiation, storage conditions and dose rate. So the aim of the present work was to investigate to what extent the above mentioned factors could influence the post-irradiation dose assessment using the ESR technique. (author).

1996-12-31

104

Electron linear accelerators for radiotherapy  

International Nuclear Information System (INIS)

Present-day requirements for radiotherapy equipment are considered. The recently developed linacs of LUE-5, LUE-25, LUE-15MM models, as well as a newly designed unified series of medical linacs of LUER-5M, LUER-20M, LUER-40M models are described in brief. The main scientific and technical problems that were solved during their construction, namely, development of accelerating structures, a radiation head, dosimetry equipment, a programming unit, a magnetic mirror etc. are described.

1983-06-01

105

Dosimetry in dental radiology. Dentascan spiral CT versus panoramic radiography  

International Nuclear Information System (INIS)

The study compares the doses absorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations.

1999-05-01

106

Development and evaluation for passive dosimeter using several solid dosimeters  

International Nuclear Information System (INIS)

Passive dosimeters for personal and area radiation monitor in space have been developed mainly for dosimetry in low-earth-orbit (LEO) radiation environments of Space Shuttles and the International Space Station. The responses of several dosimeters have been evaluated by heavy ions and also its variation for individual dosimeter element. (author)

2005-05-01

107

Comparative study of convolution, superposition, and fast superposition algorithms in conventional radiotherapy, three-dimensional conformal radiotherapy, and intensity modulated radiotherapy techniques for various sites, done on CMS XIO planning system  

UK PubMed Central (United Kingdom)

The aim of this study is to compare the dosimetry results that are obtained by using Convolution, Superposition and Fast Superposition algorithms in Conventional Radiotherapy, Three-Dimensional Conformal...Full Text Available

2009-01-01

108

Automated remote positioning and examination of FFTF reactor power characterization dosimeters  

Energy Technology Data Exchange (ETDEWEB)

The Fast Flux Test Facility (FFTF) reactor characterization by the Hanford Engineering Development Laboratory (HEDL) includes extensive neutronic measurements during startup and initial operation. To aid in the handling and counting of the thousands of passive dosimeters used as part of this effort, an automated dosimetry specimen handling, positioning, and counting system was designed and developed by Westinghouse Hanford for the Department of Energy.

1981-05-04

109

Applications of Bonner sphere detectors in neutron field dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)

1983-09-01

110

6. Workshop on heavy-charged particles in biology and medicine. Book of abstracts  

Energy Technology Data Exchange (ETDEWEB)

Topics of this proceedings are: DNA damage and repair; Space research; Cell and tissue radiobiology; Treatment planning 1: The role of clinical RBEs; Treatment planning 2: Dose optimization and inverse planning; Dosimetry; Clinical results of particle therapy and new techniques; Status reports and future developments. Separate abstracts were prepared for 79 chapters. (orig./SR)

1997-09-01

111

Quantum computing for physics research  

Energy Technology Data Exchange (ETDEWEB)

Quantum computers hold great promises for the future of computation. In this paper, this new kind of computing device is presented, together with a short survey of the status of research in this field. The principal algorithms are introduced, with an emphasis on the applications of quantum computing to physics. Experimental implementations are also briefly discussed.

2006-04-01

112

Quantum computing  

UK PubMed Central (United Kingdom)

Quantum computing is a quickly growing research field. This article introduces the basic concepts of quantum computing, recent developments in quantum searching, and decoherence in a possible quantum...Full Text Available

2001-10-09

113

Interactive computer programs in sequence data analysis.  

UK PubMed Central (United Kingdom)

We present interactive computer programs for the analysis of nucleic acid sequences. In order to handle these programs, minimum computer experience is sufficient. The nucleotide sequence of the human...Full Text Available

1982-01-11

114

Image Analysis and Computer Vision: 1996.  

Science.gov (United States)

... Title : Image Analysis and Computer Vision: 1996. ... bibliography,. Corporate Author : MARYLAND UNIV COLLEGE PARK COMPUTER VISION LAB. ...

1997-01-01

115

Computer Lab  

USGS Gallery

USGS geologists Peter Triezenberg and William Danforth sit with WHOI/LDEO Computer Technician Tom Bolmer in the Healy computer lab. This was during a scientific expedition to map the Arctic seafloor....

2009-01-28

118

Quantum computing and the chaotic amplifier  

Energy Technology Data Exchange (ETDEWEB)

A new model for computations is considered which combines the quantum computer with the chaotic dynamics amplifier, based on the logistic map. We discuss the satisfiability problem and argue that the problem can, in principle, be solved in polynomial time if one uses the new model for computations.

2003-12-01

123

Computational approaches to discovering semantics in molecular biology  

Energy Technology Data Exchange (ETDEWEB)

One of the central questions of molecular biology is the discovery of the semantics of DNA. This discovery relies in a critical way on a variety of expensive computations. In order to solve these computations, both parallel computers and special-purpose hardware play a major role.

1989-07-01

126

Type tests to the automatic thermoluminescent dosimetry system acquired by the CPHR for personal dosimetry; Pruebas tipo al sistema de dosimetria termoluminiscente automatico adquirido por el CPHR para dosimetria personal  

Energy Technology Data Exchange (ETDEWEB)

The CPHR individual monitoring service acquired an automatic RADOS TLD system to improve its capacities to satisfy the increasing needs of their national customers. The TLD system consists of: two automatic TLD reader, model DOSACUS, a TLD irradiator and personal dosimeters card including slide and holders. The dosimeters were composed by this personal dosimeters card and LiF:Mg,Cu,P (model GR-200) detectors. These readers provide to detectors a constant temperature readout cycle using hot nitrogen gas. In order to evaluate the performance characteristics of the system, different performance tests recommended by the IEC 1066 standard were carried out. Important dosimetric characteristics evaluated were batch homogeneity, reproducibility, detection threshold, energy dependence, residual signal and fading. The results of the tests showed good performance characteristics of the system. (Author)

2006-07-01

127

The use of calcium silicate bricks for retrospective dosimetry  

International Nuclear Information System (INIS)

The suitability of calcium silicate bricks (CSBs) for the retrospective measurement of gamma dose using luminescence techniques has been investigated. Bricks of this type are distinguished from fired clay bricks by containing negligible clay and requiring comparatively low temperature treatment during manufacture. They have been used widely in the construction f buildings in the Former Soviet Union since the 1970s but hitherto have not been used for retrospective dosimetry measurements. A procedure based on the se of the 210 deg. C thermoluminescence (TL) peak of quartz was tested with granular quartz extracted from three types of CSB, one of which had been taken from a settlement downwind of Chernobyl. The degree to which the residual geological TL signal within the temperature range of the 210 deg. C L peak had been reduced during manufacture varied with brick type; the levels of residual TL corresponded, in the samples tested, to absorbed doses n the range ...

2004-02-01

128

Performance testing of selected types of electronic personal dosimeters used in Sudan  

International Nuclear Information System (INIS)

Measurements were carried out for calibration and performance testing of a set of 10 electronic personal dosimeters (EPDs) at the Secondary Standard Dosimetry Laboratory of Sudan. Calibrations were carried out at three X-ray beam qualities described in ISO standard 4037 in addition to 137Cs and 60Co gamma ray beams. The experimental was performed with EPDs mounted on ICRU Slab phantom. X-ray and ?-ray beams were characterized in terms of air kerma free-in-air which were converted to the known delivered personal dose equivalent, Hp(10) using appropriate the air kerma to personal dose equivalent conversion coefficients. Dosimeters tested showed excellent energy and angular response and relative error of indication within the recommended limit for photon energies from 65 keV to 1.25 MeV. The study showed encouraging results for using electronic dosimeters in personal dosimetry.

2010-12-01

129

Performance evaluation of the conventional Brazilian industries radiation protection in the small industrial gauges and industrial radiography areas; Sistema de avaliacao de desempenho em radioprotecao das industrias convencionais brasileiras nas areas de medidores nucleares e radiografia industrial  

Energy Technology Data Exchange (ETDEWEB)

This works evaluates by punctuation the performance in conventional Brazilian industries radiation protection area which make use of small industrial gauges and industrial radiography. It proposes, procedures for industry self-evaluation, besides a new radiation protection plans pattern for the small industrial gauges area. The data source where inspection reports of Dosimetry Radiation Protection Institute/Nuclear Energy Commission conventional Brazilian industries' radiation protection plans, beyond visitation to the inspection place. The performance evaluation has been realized both in the administrative and operational aspects of the industries. About of 60% of the industries have a satisfactory register control which does not happen to the operational control. The performance evaluation advantage is that industries may self-evaluate, foreseeing Dosimetry Radiation Protection Institute's regulation inspections, correcting ...

1999-08-01

130

Measurements and elimination of Cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry  

International Nuclear Information System (INIS)

In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component of a fiber-optic radiation detector and to detect a real ...

2007-08-21

131

ESR dosimetry of irradiated chicken legs and chicken eggs  

Energy Technology Data Exchange (ETDEWEB)

Ionising radiation induces stable free radicals in chicken bones and in the shell of chicken eggs which can be detected, by the electrons spin resonance (ESR) technique, well beyond the shelf-life of the food and can be used for dosimetry. The method usually adopted to evaluate ``a posteriori`` the dose given during the ionising radiation treatment of food, is the dose additive method. To assess the dose, the ESR signal amplitude of the irradiated food (bone or egg shell in the present case) is measured and then the dose-effect relationship is obtained by re-irradiating the sample with some additive doses (usually of 1 kGy). The dose-effect curve is back-extrapolated and the initial given dose determined. At the Istituto Superiore di Sanita (ISS), Rome, Italy, a research programme was approved two years ago aimed to, (1) study new methodological approaches for ESR dose assessment, and (2) analyse the factors which may influence the ESR readout of irradiated chicken ...

1996-12-31

132

Analysis of radioactivity levels in the surrounding of the Aube storage plant (F.M.A.-V.C.). year 2007. Presentation, results and methods; Analyse des niveaux de la radioactivite dans les environs du centre de stockage F.M.A.-V.C. de l'Aube. Annee 2007. Presentation, resultats et methodes  

Energy Technology Data Exchange (ETDEWEB)

The study had three objectives: to collect information that explain the impact of the Aube storage center (C.S.A.) on environment and allow to evaluate the consequences for man, secondly, to build a referential for any future inquiry or follow-up, thirdly, to allow to the local commission of information to elaborate an information towards the side residents and local actors that take into account their questions. Trees, waters, sediments, soils, grass, products of gardens and vineyards were the object of sampling, their dosimetry is given in this report. Other dosimetry measures were made along the nuclear site and the results are equally in this report. (N.C.)

2007-07-01

133

Use of Computer Vision and Force Sensors for Tight ...  

Science.gov (United States)

... Accession Number : ADD811953. Title : Use of Computer Vision and Force Sensors for Tight Tolerance Assembly. Descriptive ...

1993-05-01

134

Rubin's Empirical Bayes Computations are Not Useful for Law ...  

Science.gov (United States)

... Accession Number : ADA100385. Title : Rubin's Empirical Bayes Computations are Not Useful for Law School Admissions - Comment,. ...

135

RAYMAN: A FORTRAN Computer Code for Tracing Rays ...  

Science.gov (United States)

... Descriptors : *COMPUTERIZED SIMULATION, *HUMAN BODY, *WOUND BALLISTICS, COMPUTER PROGRAMS, PROJECTILES, MATRICES ...

1977-11-01

136

Optical Phenomena in Computer Vision,  

Science.gov (United States)

... Accession Number : ADA152970. Title : Optical Phenomena in Computer Vision,. Corporate Author : ROCHESTER UNIV ...

1984-03-01

137

Issues in Computer Network Security.  

Science.gov (United States)

... Accession Number : ADA060007. Title : Issues in Computer Network Security. Descriptive Note : Technical rept.,. Corporate ...

1978-09-01

138

Depth Perception in Stereo Computer Vision.  

Science.gov (United States)

... Accession Number : ADA019663. Title : Depth Perception in Stereo Computer Vision. Descriptive Note : Technical rept.,. ...

1975-10-01

139

Computer and Network Security Information  

Science.gov (United States)

Computer And Network Security: Information For Everyone: This presentation was originally prepared as the 14th talk in a series known as "The Programmer's ...

140

Adaptive System and Method for Responding to Computer ...  

Science.gov (United States)

Page 1. Adaptive system and method for responding to computer network security attacks Abstract A dynamic network security ...

2002-07-11

141

A Computer Vision System forAnalyzing Images of Rough Hardwood Lumber  

Science.gov (United States)

... In this paper research aimed at creating a computer vision system to power such an optimal edging and ... ...

142

sup 131 I treatment of thyroid papillary carcinoma in a patient with renal failure  

Energy Technology Data Exchange (ETDEWEB)

Procedures for {sup 131}I ablation in renal failure are not known. In one patient receiving dialysis, detailed dosimetry and health safety aspects were obtained. The results showed insignificant contamination of equipment, but a surprisingly significant reduction in biologic half-life of {sup 131}I due to efficient dialysis extraction. The data indicate that {sup 131}I ablation can be done safely and easily during dialysis but that much higher {sup 131}I doses must be used to achieve equivalent results to those obtained in patients with normal renal function.

1990-12-15

143

Review of electron beam therapy physics  

Energy Technology Data Exchange (ETDEWEB)

For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)

2006-07-07

144

Organ doses and integral doses in X-ray diagnosis of the chest and of the head  

International Nuclear Information System (INIS)

Organ and tissue doses and integral doses in patients due to diagnostic x-ray examinations of the chest and of the head will be presented. These data have been obtained by measuring the dose distributions in man phantoms by LiF-dosimetry. The data will be compared with data obtained by Monte-Carlo calculations. To obtain average organ doses for a special type of examination for the population or for a specified subpopulation in the variation of the exposure, data due to the different techniques used by the different radiologists has to be known. Such data will be presented. The results of the investigation will be discussed in connection with the concept of the 'somatic significant.

1977-04-01

145

Nuclear forensics  

International Nuclear Information System (INIS)

Nuclear forensics is the analysis of nuclear materials recovered from either the capture of unused materials, or from the radioactive debris following a nuclear explosion and can contribute significantly to the identification of the sources of the materials and the industrial processes used to obtain them. In the case of an explosion, nuclear forensics can also reconstruct key features of the nuclear device. Nuclear forensic analysis works best in conjunction with other law enforcement, radiological protection dosimetry, traditional forensics, and intelligence work to provide the basis for attributing the materials and/or nuclear device to its originators. Nuclear forensics is a piece of the overall attribution process, not a stand-alone activity

2010-02-01

146

Luminescence characteristics of LiCaAlF6:Eu phosphor  

British Library Electronic Table of Contents (United Kingdom)

A simple method for preparing LiCaAlF6:Eu2+ phosphor is reported. Photoluminescence (PL) and thermoluminescence (TL) studies were carried out. The TL sensitivity of the phosphor is nearly twice that of CaSO4:Dy TLD phosphor. Several other properties required for TL dosimetry are superior as well. It is suggested that the phosphor can be a suitable replacement for CaSO4:Dy. (Copyright 2007 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim)

2007-01-01

147

INEEL BNCT research program. Annual report, January 1, 1996--December 31, 1996  

Energy Technology Data Exchange (ETDEWEB)

This report is a summary of the progress and research produced for the Idaho National Engineering and Environmental Laboratory (INEEL) Boron Neutron Capture Therapy (BNCT) Research Program for calendar year 1996. Contributions from the individual investigators about their projects are included, specifically, physics: treatment planning software, real-time neutron beam measurement dosimetry, measurement of the Finnish research reactor epithermal neutron spectrum, BNCT accelerator technology; and chemistry: analysis of biological samples and preparation of {sup 10}B enriched decaborane.

1997-04-01

148

INEEL Advanced Radiotherapy Research Program Annual Report 2001  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.

2002-04-01

149

INEEL Advanced Radiotherapy Research Program Annual Report 2001  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.

2002-04-30

150

Video equipment of tele dosimetry and audio  

International Nuclear Information System (INIS)

To develop a work in an area with high radiation, it requires of a detailed knowledge of the surroundings work, a communication and effective vision, a near dosimetric control. In a work where the spaces variables and reduced accesses exist, noise that hinders the communication, defendant operative condition, radiation field and taking of decision, it is necessary to have tools that allow a total control of the environment to make opportune and effective decisions, there where the task is developed. Under this elementary concept, it was developed in the Laguna Verde Central a project that it allowed a mechanism, interactive of control in spaces complex; to see, to hear, to speak, to measure. This concept takes to the creation of an equipped system with closed circuit of television, wireless communication systems, tele dosimetry wireless systems, VHS and DVD recording equipment, uninterrupted energy units. The system requires of an electric power socket, and the ...

2007-07-01

151

Particokinetics In Vitro: Dosimetry Considerations for In Vitro Nanoparticle Toxicity Assessments  

Energy Technology Data Exchange (ETDEWEB)

The rapid growth in the use of in vitro methods for nanoparticle toxicity assessment has proceeded with limited consideration of the unique kinetics of these materials in solution. Particles in general and nanoparticles specifically, diffuse, settle and agglomerate in cell culture media as a function of several systemic and particle factors: media density and viscosity, particle size, shape and density. Cellular dose then is also a function of these factors as they determine the rate of transport of nanoparticles to cells in culture. Here we develop and apply the principles of particokinetics and dosimetry in vitro and outline an approach for simulation of nanoparticle particokinetics in cell culture systems. We illustrate that where equal mass concentrations (?g/ml) imply equal doses for dissimilar materials, the corresponding particle number or surface area concentration doses differ by orders of magnitude. When rates of diffusional and gravitational particle ...

2007-02-01

152

Discrepancies in molar extinction coefficients of Fe"3"+ in Fricke dosimetry  

International Nuclear Information System (INIS)

Values of the chemical yield, G, and of the molar extinction coefficient, epsilon, for Fricke dosimetry, have been recommended by ICRU. For epsilon, the value in ICRU Reports 17 and 21, 2205 1.mol"-"1.cm"-"1, based on an analysis of 83 reported values. It was suggested that, where neither a careful wavelength calibration nor absorbance linearity checks had been performed, a standard error of 1.5% should be assumed; otherwise 0.15% could be accepted. Alternatively, the accuracy in applying this chemical dose meter was considered improved if there was an independent determination of epsilon with the same spectrophotometer as was used for the determination of the optical density of irradiated Fricke solution. The accuracy claimed for both methods remains questionable, since no complete argumentation could be given for the differences of up to 13% in the published values. Taking into account the discussion of the sources of error by Bryant, Broszkiewicz and Ellis, we ...

1977-12-09

153

The Computation Directorate at Lawrence Livermore National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

The Computation Directorate at Lawrence Livermore National Laboratory has four major areas of work: (1) Programmatic Support -- Programs are areas which receive funding to develop solutions to problems or advance basic science in their areas (Stockpile Stewardship, Homeland Security, the Human Genome project). Computer scientists are 'matrixed' to these programs to provide computer science support. (2) Livermore Computer Center (LCC) -- Development, support and advanced planning for the large, massively parallel computers, networks and storage facilities used throughout the laboratory. (3) Research -- Computer scientists research advanced solutions for programmatic work and for external contracts and research new HPC hardware solutions. (4) Infrastructure -- Support for thousands of desktop computers and numerous LANs, ...

2006-09-07

154

Computer science handbook. Vol. 13.3. Environmental computer science. Computer science methods for environmental protection and environmental research  

International Nuclear Information System (INIS)

Environmental computer science is a new partial discipline of applied computer science, which makes use of methods and techniques of information processing in environmental protection. Thanks to the inter-disciplinary nature of environmental problems, computer science acts as a mediator between numerous disciplines and institutions in this sector. The handbook reflects the broad spectrum of state-of-the art environmental computer science. The following important subjects are dealt with: Environmental databases and information systems, environmental monitoring, modelling and simulation, visualization of environmental data and knowledge-based systems in the environmental sector. (orig.).

155

Study on thermal-hydraulics during a PWR reflood phase  

International Nuclear Information System (INIS)

In-core thermal-hydraulics during a PWR reflood phase following a large-break LOCA are quite unique in comparison with two-phase flow which has been studied widely in previous researches, because the geometry of the flow path is complicated (bundle geometry) and water is at extremely low superficial velocity and almost under stagnant condition. Hence, some phenomena realized during a PWR reflood phase are not understood enough and appropriate analytical models have not been developed, although they are important in a viewpoint of reactor safety evaluation. Therefore, author investigated some phenomena specified as important issues for quantitative prediction, i.e. (1) void fraction in a bundle during a PWR reflood phase, (2) effect of radial core power profile on reflood behavior, (3) effect of combined emergency core coolant injection on reflood behavior, and (4) the core separation into two thermal-hydraulically different regions and the in-core flow circulation behavior observed ...

1983-12-13

156

Studies on formation and structures of ultrafine Cu precipitates in Fe-Cu model alloys for reactor pressure vessel steels using positron quantum dot confinement in the precipitates by their positron affinity. JAERI's nuclear research promotion program, H11-034 (Contract research)  

Energy Technology Data Exchange (ETDEWEB)

Positron annihilation experiments on Fe-Cu model dilute alloys of nuclear reactor pressure vessel (RPV) steels have been performed after neutron irradiation in JMTR. Nanovoids whose inner surfaces were covered by Cu atoms were clearly observed. The nanovoids transformed to ultrafine Cu precipitates by dissociating their vacancies after annealing at around 400degC. The nanovoids and the ultrafine Cu precipitates are strongly suggested to be responsible for irradiation-induced embrittlement of RPV steels. Effects of Ni, Mn and P addition on the nanovoid and Cu precipitate formations were also studied. The nanovoid formation was enhanced by Ni and P, but suppressed by Mn. The Cu precipitates after annealing around 400degC were almost free from these doping elements and hence were pure Cu in the chemical composition. Furthermore the Fermi surface of the 'embedded' Cu precipitates with a body centered cubic crystal structure was obtained from two dimensional angular ...

2003-03-01

157

Mercury flow experiments. 3. Simulation test plan under abnormal condition  

Energy Technology Data Exchange (ETDEWEB)

Japan Atomic Energy Research Institute (JAERI) and High Energy Accelerator Research Organization (KEK) are promoting construction plan of Material-Life Science Facility, which is consisted of Muon Science Facility and Neutron Scattering Facility, in order to open up the new science fields. The Neutron Scattering Facility will be utilized for advanced fields of Material and Life science using high intensity neutrons generated by the spallation reaction induced by injecting a 1 MW pulsed proton beam onto a mercury target. Design of the spallation mercury target system is in progress to obtain good neutron performance keeping high reliability and safety. The target material is mercury. As a result of the spallation reaction, large amount of radioactive spallation products are to be contained in the mercury. Therefore to establish the safety of the target system, transient behaviors of the system during anticipated events should be well understood. The safety ...

2002-02-01

158

MTX final report  

Energy Technology Data Exchange (ETDEWEB)

The MTX experiment was proposed in 1986 to apply high frequency microwaves generated by a free-electron laser (FEL) to electron cyclotron resonance heating (ECRH) in a high field, high density tokamak. As the absorption of microwaves at the electron cyclotron resonance requires high frequencies, the opportunity of applying a free-electron laser has appeal as the device is not limited to frequencies in the microwave or long millimeter wavelength regions, in contrast to many other sources. In addition, the FEL is inherently a high power source of microwaves, which would permit single units of 10 MW or more, optimum for reactors. Finally, it was recognized early in the study of the application of the FEL based on the induction linear accelerator, that the nonlinear effects associated with the intense pulses of microwaves naturally generated would offer several unique opportunities to apply ECRH to current drive, MHD control, and other plasma effects. It was consequently decided to adapt ...

1994-01-01

159

Experiences in radioactive gaseous effluent management in JAERI  

International Nuclear Information System (INIS)

In the Japan Research Reactor-II (JRR-2), the main source of _4_1Ar generation is the exhaust air from the horizontal experimental holes and the pneumatic tubes. For the horizontal experimental holes, the flow of exhaust air through the holes was decreased by improving the airtightness, and a decay duct of capacity 2.4 m_3 was installed in the middle of the exhaust line. In consequence, the release rate of _4_1Ar was reduced by 6-8%. For the pneumatic tubes, a mechanical shutter was installed in the tube. The shutter stops the exhaust air flow, except when the pneumatic tube is used. Prior to the use, the activated air in the tube is led to a decay tank. As a result, the _4_1Ar release rate was reduced by 10-20%. By the above means, the yearly exposure at the site boundary was reduced to 0.36 mR from 2.6 mR. In Hot Laboratory for metallurgical examination of spent fuel, the exhaust filtration system consists of filters in the cave, i.e. frame trap, prefilter, HEPA filter, and the main ...

1983-05-01

160

Quantum computing with trapped ions  

Energy Technology Data Exchange (ETDEWEB)

Quantum computers hold the promise of solving certain computational tasks much more efficiently than classical computers. We review recent experimental advances towards a quantum computer with trapped ions. In particular, various implementations of qubits, quantum gates and some key experiments are discussed. Furthermore, we review some implementations of quantum algorithms such as a deterministic teleportation of quantum information and an error correction scheme.

2008-12-15

161

Quantum computing and probability  

Energy Technology Data Exchange (ETDEWEB)

Over the past two decades, quantum computing has become a popular and promising approach to trying to solve computationally difficult problems. Missing in many descriptions of quantum computing is just how probability enters into the process. Here, we discuss some simple examples of how uncertainty and probability enter, and how this and the ideas of quantum computing challenge our interpretations of quantum mechanics. It is found that this uncertainty can lead to intrinsic decoherence, and this raises challenges for error correction. (viewpoint)

2009-11-25

162

Cloud computing: A silver lining for climate change? - Climate Action Programme  

Wastenet

... - Climate Action Programme cloud computing, climaet change, carbon emissions, verdantix, cloud, it, computer cloud computing, climaet change, carbon emissions,...verdantix, cloud, it, computer GreenMedia.com AidForumOnline.org ClimateActionProgramme.org Search Climate Action... In partnership with the United Nations ...

163

The Optical Videodisc in Computer Based Education  

UK PubMed Central (United Kingdom)

In a new approach to medical computer based education (CBE) students at several U.S. and Canadian health professions schools have been using an optical videodisc under computer control to study basic...Full Text Available

1984-11-07

164

Principles of quantum computing  

Energy Technology Data Exchange (ETDEWEB)

This contribution is intended to introduce the principles of quantum computing to those who always wanted to know about quantum computing but never dared to ask. (copyright 2007 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

2007-11-15

165

Control and Dynamic Approach to Robust Quantum Computing.  

Science.gov (United States)

During the entire performance period, from 12 May 2003 through 31 December 2006, we have conducted theoretical and computational research on quantum control problems central to quantum computation. In particular we completed a thorough and rigorous analys...

2006-01-01

166

Computing needs of the superconducting super collider  

Energy Technology Data Exchange (ETDEWEB)

Following a brief description of the SSC, the computing needs are discussed for both the accelerator design and the experimentation. The computing power required is considerably beyond that being used at present facilities, and parallel processing is expected to play an important role in supplying these needs.

1984-01-01

167

Computer-Assisted Discovery and Proof  

Energy Technology Data Exchange (ETDEWEB)

With the advent of powerful, widely-available mathematical software, combined with ever-faster computer hardware, we are approaching a day when both the discovery and proof of mathematical facts can be done in a computer-assisted manner. his article presents several specific examples of this new paradigm in action.

2007-12-10

168

Amazon.com: Automotive Embedded Systems Handbook (Industrial Information Technology) (9780849380266): Nicolas Navet, Francoise Simonot-Lion: Books  

Wastenet

...Electronic equipment,Embedded computer systems,Technology & Engineering,Automotive - General,COMPUTERS / Computer Engineering,TECHNOLOGY & ENGINEERING / Electronics ...

169

A Computer Vision System for Automated Grading of Rough Hardwood Lumber Using a Knowledge-Based Approach  

Science.gov (United States)

... in this paper is aimed at developing a computer vision system that will be used to automatically grade rough hardwood lumber. The purpose of the computer vision system is to locate and identify grading def...

170

Quantum Discord and Quantum Computing - An Appraisal  

CERN Document Server

We discuss models of computing that are beyond classical. The primary motivation is to unearth the cause of nonclassical advantages in computation. Completeness results from computational complexity theory lead to the identification of very disparate problems, and offer a kaleidoscopic view into the realm of quantum enhancements in computation. Emphasis is placed on the `power of one qubit' model, and the boundary between quantum and classical correlations as delineated by quantum discord. A recent result by Eastin on the role of this boundary in the efficient classical simulation of quantum computation is discussed. Perceived drawbacks in the interpretation of quantum discord as a relevant certificate of quantum enhancements are addressed.

2011-01-01

171

Information processing, computation, and cognition  

British Library Electronic Table of Contents (United Kingdom)

Computation and information processing are among the most fundamental notions in cognitive science. They are also among the most imprecisely discussed. Many cognitive scientists take it for granted that cognition involves computation, information processing, or both ? although others disagree vehemently. Yet different cognitive scientists use ?computation? and ?information processing? to mean different things, sometimes without realizing that they do. In addition, computation and information processing are surrounded by several myths; first and foremost, that they are the same thing. In this paper, we address this unsatisfactory state of affairs by presenting a general and theory-neutral account of computation and information processing. We also apply our framework by analyzing the relatio...

2011-01-01

172

Cost savings through effective use of network resources  

Energy Technology Data Exchange (ETDEWEB)

The role of computers has become increasingly important for oil and gas field research and operations support. Today, the computer network is an integral part of the increasingly complex computing environment that exists in many companies. Computer networks allow users to efficiently share information, software, and hardware to support critical global communication needs. Because users are able to share software and hardware, the use of computer networks can also result in significant cost savings. This paper describes typical network loading and demand levels for shared software applications on a computer network that has been used for several years.

1994-12-31

173

Computer system architecture. Second edition  

Energy Technology Data Exchange (ETDEWEB)

A register transfer language is used to present the basic concepts of computer hardware architecture. Material needed for understanding computer organisation, design, and programming is included. The various functional units of digital computers (central processor, microprogram control; arithmetic algorithms; input-output; and memory organisation), are examined. A basic computer is developed to demonstrate the components of computer hardware and software architecture. Parallel processing and multiprocessor systems are discussed. Numerous MSI and LSI digital functions are introduced with explanations of their characteristics. Cache memory and the hardware requirements for a memory management unit are covered.

1982-01-01

174

this issue NASA Cloud Computing Platform: Nebula  

Science.gov (United States)

National Aeronautics and Space Administration. Issue 2. June 2010 this issue. Nebula: Cloud Computing p.1. Better Business with EA p.2 ...

175

WINPEPI updated: computer programs for epidemiologists, and their teaching potential  

UK PubMed Central (United Kingdom)

BackgroundThe WINPEPI computer programs for epidemiologists are designed for use in practice and research in the health field and as learning or teaching aids. The programs are free,...Full Text Available

176

Using Advanced Computer Vision Algorithms on Small Mobile ...  

Science.gov (United States)

... FL, April 18-20, 2006 Using Advanced Computer Vision Algorithms on Small Mobile Robots G. Koguta,F. Birchmoreb,E ...

2006-04-20

177

Update on Waterjet Cutting: How CNCs (Computer Numerical ...  

Science.gov (United States)

... Accession Number : ADD802897. Title : Update on Waterjet Cutting: How CNCs (Computer Numerical Controls) Are Turning the Tide. ...

178

Type II Quantum Computing With Superconductors.  

Science.gov (United States)

The results of this research centered on the experimental studies of a single superconducting persistent current qubit, the implementation of type-II algorithms using these qubits, and the proposal for adiabatic quantum computing using these qubits. The m...

2004-01-01

179

This perspective view of Venus, generated by computer  

Science.gov (United States)

This perspective view of Venus, generated by computer from NASA's Magellan data and color-coded with emissivity, shows part of the lowlands to the north of ...

180

Summer Opportunities-Teacher Enhancement (NSF 96-89)  

Science.gov (United States)

... exercises and biotechnology labs and didactic material. It includes sessions on computer and media ... computers, and learn how IPT activities and materials can help meet their curriculum objects ...

181

Resources for Observing at CTIO  

Science.gov (United States)

we have a colloquium scheduled. Computing: register your machine and check our network security and visitor computer policies. For Our Information: Once arranged, please let us...

2011-02-25

182

Quantum chromodynamics with advanced computing  

Energy Technology Data Exchange (ETDEWEB)

We survey results in lattice quantum chromodynamics from groups in the USQCD Collaboration. The main focus is on physics, but many aspects of the discussion are aimed at an audience of computational physicists.

2008-07-01

183

Parallel Algorithms for Computer Vision.  

Science.gov (United States)

The general goals of this research effort is to explore the potential applications and performance of fine grained computer architectures for vision. The body of this report gives a brief overview of the results of the research during the first twelve mon...

1987-01-01

184

Overview of Computer Simulation Modeling Approaches and Methods  

Science.gov (United States)

Sep 1, 2011 ... 2005. Computer simulation modeling of recreation use: current status, case studies, and future directions. Gen. Tech. Rep. RMRS-GTR-143. ...

185

NASA Nebula in Action: Cloud Computing Case Examples  

Science.gov (United States)

NASA Nebula in Action: Cloud Computing Case Examples. James Williams, NASA Ames Research Center, james.f.williams@nasa.gov. Abstract In 2009 ...

186

Limitations of silicon devices for quantum computing  

Energy Technology Data Exchange (ETDEWEB)

There is considerable interest in the use of silicon devices as qubits for quantum computing. The existence of nuclear spin in a silicon isotope and the complex band structure of silicon are unfavourable for this application of silicon devices. (viewpoint)

2004-04-28

187

Korea Joins International Computing Infrastructure  

Science.gov (United States)

... Society Physics Press Release 05-175Korea Joins International Computing Infrastructure ... connectivity with Korea in a ceremony last month. Facilitated by the Korea Institute for Science and ...

188

ITCD - HOME COMPUTER SECURITY TRAINING  

Science.gov (United States)

Explore security settings for home equipment, learn how to browse safely and securely, and keep your computer up to date and secure. Explore different account ...

189

Histopathological Image Analysis: A Review  

UK PubMed Central (United Kingdom)

Over the past decade, dramatic increases in computational power and improvement in image analysis algorithms have allowed the development of powerful computer-assisted analytical approaches...Full Text Available

2009-01-01

190

Ellison on Grid computing it's invincible, inevitable  

CERN Multimedia

Speaking to thousands of attendees at Oracle's customer and partner conference, Chairman and CEO Larry Ellison launched Oracle's Grid Computing initiative (1/2 page).

2003-01-01

191

Distributed Computer Networks in Support of Complex Group Practices  

UK PubMed Central (United Kingdom)

The economics of medical computer networks are presented in context with the patient care and administrative goals of medical networks. Design alternatives and network topologies are discussed with...Full Text Available

1978-11-09

192

Computer tomographic diagnosis of intrathoracic lipoma  

Energy Technology Data Exchange (ETDEWEB)

A case of intrathoracic lipoma in a child is presented. The diagnosis was made before operation by means of computer-assisted tomography, a non-interventional procedure.

1984-04-14

193

Computer Vision Hardware System for Automating Rough Mills of Furniture Plants  

Science.gov (United States)

... company. To automate this initial cutup requires a computer vision system that can locate and identify surface defects ... ...

194

Computer Lab on Healy  

USGS Gallery

USGS scientists Ellyn Montgomery and William Danforth discuss incoming data in a computer lab on U.S. Coast Guard Cutter Healy. This was during a scientific expedition to map the Arctic seafloor....

2009-01-28

195

Computer Controlled Telerobot Wrist Module  

Science.gov (United States)

Disclosed in this proposal are plans to construct a patent pending wrist module with computer control, configurable to form high-dexerity telerobotic arms ...

196

Computed tomography of head in Clinic Pediatrics  

Energy Technology Data Exchange (ETDEWEB)

138 unselected head tomographies of children by computer are reported and analysed. The major aspect stressed by the authors is the excellent precision of this radiological technique.

1982-02-01

197

Computational biology for ageing  

UK PubMed Central (United Kingdom)

High-throughput genomic and proteomic technologies have generated a wealth of publicly available data on ageing. Easy access to these data, and their computational analysis, is of great importance in...Full Text Available

2011-01-12

198

Cloud Computing at JPL | JPL Mission Planning and Execution  

Science.gov (United States)

He said, I had heard of Cloud Computing when I was in grad school, but they had presentations on it at EclipseCon. I was sold that it was something that ...

199

Choosing a Microcomputer: What to Look For and What to Avoid  

UK PubMed Central (United Kingdom)

Many family physicians are considering purchasing a computer in the near future. This article explains some of the jargon of the computer industry and describes the various specifications that will...Full Text Available

1984-04-01

200

Arc Habitat Suitability Index computer software  

Science.gov (United States)

Sep 1, 2011 ... Publication Information. Bookmark and Share. Title: Arc Habitat Suitability Index computer software. Author: Juntti, Thomas M.; Rumble, Mark A. ...

201

A Computer Vision System for Inspection of Light Emitting ...  

Science.gov (United States)

... Accession Number : ADD801284. Title : A Computer Vision System for Inspection of Light Emitting Diodes. Descriptive Note : Conference paper,. ...

1986-06-01

202

Workshop on tritium safety and environmental effects, October 15--17, 1990, Aiken, South Carolina: Session summaries  

Energy Technology Data Exchange (ETDEWEB)

A meeting was held on October 15, 16, 17, 1990 to discuss the state of tritium safety and environmental effects. The meeting was organized with the help of the International Energy Agency planning committee consisting of K. Steinmetz, Y. Seki, G. Nardella, and G. Vivian. Representative of tritium production facilities and heavy water reactor power production were also involved. The meeting was organized to address seven topics in tritium safety that were thought to require further work. The topics were: (1) materials science, (2) environmental models, (3) environmental model validation, (4) tritiated organic compounds, (5) human dosimetry, (6) tritium sampling and measurement, and (7) long-term environmental databases.

1991-04-18

203

Report of the IPSM working party on low- and medium-energy x-ray dosimetry  

Energy Technology Data Exchange (ETDEWEB)

New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).

1991-08-01

204

Report of the IPSM working party on low- and medium-energy x-ray dosimetry  

International Nuclear Information System (INIS)

New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).

1991-01-01

205

Radioactive decay data tables  

Energy Technology Data Exchange (ETDEWEB)

The estimation of radiation dose to man from either external or internal exposure to radionuclides requires a knowledge of the energies and intensities of the atomic and nuclear radiations emitted during the radioactive decay process. The availability of evaluated decay data for the large number of radionuclides of interest is thus of fundamental importance for radiation dosimetry. This handbook contains a compilation of decay data for approximately 500 radionuclides. These data constitute an evaluated data file constructed for use in the radiological assessment activities of the Technology Assessments Section of the Health and Safety Research Division at Oak Ridge National Laboratory. The radionuclides selected for this handbook include those occurring naturally in the environment, those of potential importance in routine or accidental releases from the nuclear fuel cycle, those of current interest in nuclear medicine and fusion reactor technology, and some of ...

1981-01-01

206

Radio cellular phones and health: Up-to-date research on human health; Radiotelephones cellulaires et sante: mise au point des recherches portant sur la sante chez l'homme  

Energy Technology Data Exchange (ETDEWEB)

Cellular telephones emit a radiofrequency electromagnetic field, part of which is absorbed in the user's head. Many studies have been conducted to look for their possible health hazard to human, at the experimental, epidemiological or clinical level. After a short recall on dosimetry, the author describes the state-of-the art about harmful and irreversible effects, up to now not confirmed, and about some benign symptoms which look absolutely actual. A causal relationship of the electromagnetic field on these benign symptoms is however not proven; other, studies are running to evaluate their possible long-term consequences. Interferences with cardiac pacemakers can easily be avoided by holding the telephone handset farther than 10 cm. (author)

1999-12-01

207

Radiation therapy and Ewing's sarcoma in childhood  

International Nuclear Information System (INIS)

Despite high local control rate in Ewing's sarcoma the exact indication of radiation therapy is still controversial as well as the choice of the target volume and the optimal dose of radiation. The importance of the quality of radiotherapy has been stressed in recently published data and has shown a significant impact on long term local control with adequate radiation therapy. The dramatic improvement of precision allowed by the conformal therapy and three dimensional dosimetry allow to expect a decrease of late effects expected for second malignancies. However, late sequelae and radio-induced osteosarcoma still remain the major side effects after radiotherapy. The authors discuss the results of the main trials on Ewing's sarcoma on the choice of dose and target volume. Surgery is still the preferred choice for small tumors if the foreseen outcome is identical. (authors). 28 refs.

208

Radiation protection  

International Nuclear Information System (INIS)

The book presents a very good account of all aspects of protection from ionizing radiation. The quantities and units are given and defined used in nuclear physics and dosimetry. The effects of ionizing radiation on cells and on man are described. The principles are presented of radiation protection including limits and valid regulations and decrees. Also discussed is internal irradiation and its modelling. A great part of the book is devoted to aspects of monitoring persons, the living and working environment and to the determination of internal contamination. The system of radiation protection in Czechoslovakia is described and some practical questions are discussed of protection during radiodiagnosis and radiotherapy, in the nuclear fuel cycle, in the operation of nuclear power installations and in crack detection. In conclusion a survey is given of the population exposure from various natural and artificial sources. (M.D.). 57 figs., 34 tabs., 138 refs.

1988-01-01

209

Organ doses received by atomic bomb survivors during radiological examinations at the Radiation Effects Research Foundation  

Energy Technology Data Exchange (ETDEWEB)

When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).

1991-08-01

210

Organ doses received by atomic bomb survivors during radiological examinations at the Radiation Effects Research Foundation  

International Nuclear Information System (INIS)

When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).

1991-01-01

211

Monte Carlo code comparisons for the calculation of absorbed dose per unit fluence in slab phantoms for electron energies from 50 keV to 10 MeV  

International Nuclear Information System (INIS)

The MCNPE-BO and MCNP4 Monte Carlo electron-photon codes were used to calculate the dose equivalent per unit fluence at various depths in tissue-equivalent slab phantoms for broad parallel beams of monoenergetic electrons with energies from 50 keV to 10 MeV. The study was carried out in the framework of the activities of a ICRP/ICRU Joint Task Group with the support of EURADOS WG4 (Numerical Dosimetry). Some preliminary results and comparisons as well as a general discussion on the performances of the codes are presented, demonstrating quite a satisfactory agreement among the results obtained using the two codes and those of other authors. (author).

212

Measurement of skin dose in primary irradiation of maxillary sinus carcinoma  

Energy Technology Data Exchange (ETDEWEB)

Subcutaneous involvement frequently occurs in maxillary sinus carcinoma. Radical resection does not include removal of the skin at risk. In standard postoperative wedge-pair treatment plans, the surface dose is dependent upon beam weighting, beam energy, and patient contour. Thermoluminescent dosimetry (TLD) measurements were performed to evaluate the surface dose of patients undergoing postoperative irradiation of maxillary sinus carcinoma following primary resection. When 60 Gy was delivered to isocenter with a 45 degrees wedge pair and 6 MV photons with 1 cm bolus, the subcutaneous tissues at risk received {approximately} 30 Gy. Based upon presented TLD measurements, supplemental electron beam therapy to the subcutaneous tissues if primarily involved should be considered.

1991-03-01

213

Measurement of radon daughter product burden by TLD dosemeters  

International Nuclear Information System (INIS)

A miniature device is described for measuring integral potential alpha energy concentration of radon daughter products (Csub(Rn)) for personnel and stationary dosimetry. The measuring apparatus consists of an air sampler, filters and TLD detectors. CaSO_4:Dy-teflon pellets were used as the detectors which registrate #gamma# radiation as well. The TLD-effect dependence on the potential alpha energy, as well as the fading of the detectors at 20-60 deg C after 170 hrs operation are presentd. The fading up to 40 deg C has been found to be negligible. The dosimeter may be used to measure Csub(Rh) starting with the 10"5 MeVxh/1 threshold, the accuracy being not worse than +-30%.

214

IAEA RESEARCH CONTRACTS FIRST ANNUAL REPORT. Technical reports Series No. 4  

Science.gov (United States)

Summaries are included of research contracts which expired prior to Dec. 31, 1960. The contracts were concerned with investigations of: electrophysiological responses of biological systems in nerve cells to irradiation with small doses of ionizing radiations; the mode of the protective action of certain sulfhydryl compounds against radiation effects on the synthesis of deoxyribonucleic acid, using tritium-labeled thymidine; development of a bubble chamber method of monitoring and dosimetry for Low fast neutron fluxes; effects of incorporated radioisotopes on the stability of genetic materials; interrelation of root and leaf absorption of radioisotopes in herbaceous plants; uptake of radioactive wastes by lowland rice from soils contaminated by irrigation water, and decontamination of the rice; and comparison between mutation rates induced by acute and chronic gamma irradiations. (B.O.G.)

1961-01-01

215

Health and Safety Research Division progress report for the period April 1, 1987--September 30, 1988  

Energy Technology Data Exchange (ETDEWEB)

The mission of the Health and Safety Research Division (HASRD) is to provide a sound scientific basis for the measurement and assessment of human health impacts of radiological and chemical substances. Our approach to fulfilling this mission is to conduct a broad program of experimental, theoretical, and field research based on a strong foundation of fundamental physical studies that blend into well-established programs in life sciences. Topics include biomedical screening techniques, biological and chemical sensors, risk assessment, health hazards, dosimetry, nuclear medicine, environmental pollution monitoring, electron-molecule interactions, interphase physics, surface physics, data base management, environmental mutagens, carcinogens, and tetratogens.

1989-03-01

216

Electronics Personal Dosemeter (EPD-N) Test and Evaluation Report  

Energy Technology Data Exchange (ETDEWEB)

Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization then used at another site.

2003-04-08

217

Efficiency of a lead-containing tie for radiation protection of the thyroid gland  

Energy Technology Data Exchange (ETDEWEB)

During fluoroscopy the examiner is usually protected by a radiation-reducing body shield, leaving the thyroid unprotected. The fact that the thyroid is located in a region of the neck usually covered by the shirt collar led to the idea of designing a tie with lead core, providing easy and ''decorative'' reduction of the radiation dose. Sonographic examinations were carried out in 20 volunteers (10 men, 10 women) to determine the size of the gland and its coverage by such a tie. The reduction of the surface and organ dose was assessed using film dosimetry with scattered radiation, the body of the examiner being simulated by an Alderson phantom. On average 88% of the thyroid gland surface area was covered. Surface dose was reduced to 1%, and organ dose to 10% of the value without the protection tie. (Author).

1992-11-01

218

Efficiency of a lead-containing tie for radiation protection of the thyroid gland  

International Nuclear Information System (INIS)

During fluoroscopy the examiner is usually protected by a radiation-reducing body shield, leaving the thyroid unprotected. The fact that the thyroid is located in a region of the neck usually covered by the shirt collar led to the idea of designing a tie with lead core, providing easy and ''decorative'' reduction of the radiation dose. Sonographic examinations were carried out in 20 volunteers (10 men, 10 women) to determine the size of the gland and its coverage by such a tie. The reduction of the surface and organ dose was assessed using film dosimetry with scattered radiation, the body of the examiner being simulated by an Alderson phantom. On average 88% of the thyroid gland surface area was covered. Surface dose was reduced to 1%, and organ dose to 10% of the value without the protection tie. (Author).

219

Effective dose equivalent concept in radiopharmaceutical dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source volumes and the re iden e times in total body and the target organs. Examples are given for the calculation of somatically effective dose equivalent for ...

1981-06-01

220

Effective dose equivalent concept in radiopharmaceutical dosimetry  

International Nuclear Information System (INIS)

The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source volumes and the re iden e times in total body and the target organs. Examples are given for the calculation of somatically effective dose equivalent for ...

221

Dosimetry of iodine-123 iomazenil in humans  

International Nuclear Information System (INIS)

The distribution of the central benzodiazepine receptor specific ligand iodine-123 iomazenil was investigated in seven human adults from whole-body scans, blood samples and urine collected up to 24 h after injection. Using 12 source organs, the MIRD method was applied to calculate the absorbed radiation dose of the radioligand in various organs. The urinary bladder wall (0.15 mGy/MBq), lower large intestinal wall (0.071 mGy/MBq) testes (0.044 mGy/MBq) and upper large intestined wall (0.038 mGy/MBq) received the highest absorbed doses. The average effective dose equivalent of "1"2"3I-IBZM for adults was estimated to be 0.033 mSv/MBq. (orig.).

222

Comparative dosimetry for screen film systems and intensifier fluorography in urinary incontinence of women  

International Nuclear Information System (INIS)

In 16 female patients wick colpourethrocystography was performed directly successively with large-size films as well as medium-size films (intensifier fluorography). The area exposure products were measured by a dosemeter closely attached to the diaphragm and separately for radiography and fluorography, resp. Surface doses as well as organ doses were calculated according to Rosenstein. The average radiatin doses of the active bone marrow were 6.03 mGy for examination with large-size films and 1.27 mGy for fluorography; the average gonadal doses were 7.45 mGy and 1.56 mGy, resp. The portion of fluoroscopy in radiation exposure amounted to 14.8% in large-size film examination, but was 74.0% in medium-size examination. Thus the comparative results revealed a significant reduction of the patient's radiation dose by application of intensifier fluorography in colpourethrocystography.

1987-01-01

223

Clinical application of dosimetry in electron beam therapy  

International Nuclear Information System (INIS)

In everyday radiotherapy we must carry out the determination of absorbed dose measurement according to JARP's protocol. We explained an outline of JARP's 1974 and 1986 protocol in electron beam therapy, and mentioned it about the matter that should examined. To use it easily in clinic, a simplified procedure based on precisely to JARP's 1986 protocol is practical, the character of this procedure settles briefly the determination of mean incident energy of electron beams and get ready to table of ionization to absorbed dose conversion factor for various ionization chamber. Also, this procedure almost not influence on the accuracy of determination. We described systematically practical procedure for requisite absorbed dose calculation in a patient in electron beam therapy. (author).

224

An integrating dosimeter for pulsed radiation  

Science.gov (United States)

A Pulsed Radiation Dosimetry System designed to measure radiation produced by particle accelerators is described. The problems associated with total-dose measurement of irregular shaped pulses of ionizing radiation have been simplified. The system responds to extremely narrow pulses of charged particles or X-rays using a pin diode as the detector. Direct readout of dose in rads (Si) is displayed on a 3-1/2 digit digital panel meter. The system will operate in either the multiple-pulse or single-pulse mode. The multiple-pulse mode would be useful in monitoring or tuning a linear accelerator. In the single-pulse mode the system will automatically display total dose of a transient event in real time and hold that measurement indefinitely or until the next measurement is made. The system features an automatic reset in either mode.

1983-12-01

225

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

International Nuclear Information System (INIS)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. (authors)

2008-05-01

226

A routine chemical dosimetric system using the modified ceric sulphate dosimeter  

International Nuclear Information System (INIS)

The radiolytic reduction of the Ce4+ in a 0.8N sulfuric acid was examined, with the objective of measuring large radiation doses. the ceric sulphate dosimeter was tested in the range from 1 to 20kGy. The 0.01 M sodium oxalate solution was chosen instead of the arsenious oxide solution (used in the conventional method), in order to obtain a less expensive dosimetric system than that normally use for routine chemical dosimetry. The absorption spectrum of the Ce"4"+ solution presents an absorption peak at 370 nm; the obtained molar extinction coefficients of Ce"4"+ and Ce"3"+ were 5670 and 2.7 M"-"1 cm"-"1 respectively. The purpose of this work was to establish a simple, reliable and inexpensive routine chemical dosimetric system for high doses.

1994-10-01

228

Unclas  

Science.gov (United States)

Another difference lies in the speed of star evolution. 2. Computation of Stellar Structure and Their Evolution. The structure of stars at certain instants ...

229

Trial of using computer tomography in the diagnosis of mediastinal diseases in children  

Energy Technology Data Exchange (ETDEWEB)

In 15 children (in age 2 weeks - 15 years) the computer tomography beside radiological examination was done because of mediastinal diseases. In all cases the computer tomography was valuable. In 4 cases obtained results have changed diagnostic conclusions. The examples are described showing the usefulness of the computer tomography as supplementary diagnostic method in mediastinal diseases in children.

1981-01-01

230

The studying of electron motion in crystal lattice by using computer  

International Nuclear Information System (INIS)

... 2007, 80 ?. 5. ?????? ?.?. Visual Basic-6.0, ??????, 2000, 449 ?. ????

2010-04-01

232

Security Considerations For Network-Centric Weapon ...  

Science.gov (United States)

... strategies. Computer and network security deals with cryptography, authentication, and attacks on software. Information ...

2009-09-01

233

Schlafende PC mutieren zum Supercomputer  

CERN Multimedia

With Novartis, Grid-Computing has an industrial use

2003-01-01

234

QCCM - Center for NMR Quantum Information Processing  

Science.gov (United States)

... decoherence. Descriptors : *QUANTUM COMPUTING, NUCLEAR MAGNETIC RESONANCE, JOSEPHSON JUNCTIONS. Subject ...

2011-02-16

235

Photochromes for Optical Memory  

International Science & Technology Center (ISTC)

Photochromes for New Generation of Highly Efficient Computers with Three Dimensional (3D) Optical Memory

236

On Measurement and Computation  

CERN Document Server

Inspired by the work of Feynman, Deutsch, We formally propose the theory of physical computability and accordingly, the physical complexity theory. To achieve this, a framework that can evaluate almost all forms of computation using various physical mechanisms is discussed. Here, we focus on using it to review the theory of Quantum Computation. As a preliminary study on more general problems, some examples of other physical mechanism are also given in this paper.

2011-01-01

237

Numerical methods for matrix computations using arrays of processors. Final report, 15 August 1983-15 October 1986  

Energy Technology Data Exchange (ETDEWEB)

The basic objective of this project was to consider a large class of matrix computations with particular emphasis on algorithms that can be implemented on arrays of processors. In particular, methods useful for sparse matrix computations were investigated. These computations arise in a variety of applications such as the solution of partial differential equations by multigrid methods and in the fitting of geodetic data. Some of the methods developed have already found their use on some of the newly developed architectures.

1987-04-30

239

Minimization on Stochastic Matroids  

Science.gov (United States)

... Note that the terminal ... Probability and Statistics with Reliability, Queueing, and Computer ... Weiss, G., "Stochastic Bounds on Distributions of Optimal ...

1990-07-01

241

Java-based Graphical User Interface for MAVERIC-II  

Science.gov (United States)

A computer program entitled "Marshall Aerospace Vehicle Representation in C II,

2005-01-01

242

Importance of computer tomography in paediatric diagnostics of abdominal and pelvic tumours  

Energy Technology Data Exchange (ETDEWEB)

In a joint study conducted by the University Clinic of Radiology, Graz, and the Medical University Clinic, Innsbruck, the results of computer tomography examinations of the abdomen and pelvis in 23 cases of tumours in children are discussed. In children computer tomography resents special difficulties on account of the very poorly developed fatty layers between the organs and the increased incidence of movement artifacts. The importance of computer tomography for the diagnosis of abdominal and pelvic tumours is discussed.

1980-03-01

243

Implementing Advanced Technologies in the Republic of ...  

Science.gov (United States)

... personal computers low-cost information management capabilities to television's uncanny ability to motivate and communicate. ...

1994-03-01

244

Implementation of the NAS Parallel Benchmarks in Java  

Science.gov (United States)

Several features make Java an attractive choice for High Performance Computing (HPC). In order to

2002-01-01

245

How the Air Force Should Stay Engaged in Computer Vision ...  

Science.gov (United States)

... 14 Face Detection ..... 14 Automated Mapping ...

2007-04-01

246

Fundamental study on Fuji Computed Radiography (FCR) image  

International Nuclear Information System (INIS)

Japanese (Mar 1986). Japan Tomiyoshi, Tsukasa Kakoi, Iwao Fukushima,

1986-01-01

247

Development of a Standard Data Base and Computer ...  

Science.gov (United States)

... (Author). Descriptors : (*TERMINAL FLIGHT FACILITIES ... PROGRAMMING, HANDLING), QUEUEING THEORY, STOCHASTIC PROCESSES ...

1973-01-01

252

Computer tomographic ventriculography  

Energy Technology Data Exchange (ETDEWEB)

A method for elucidating complex abnormalities of CSF circulation by using a positive contrast medium (metrizamide) and computer tomography is described. The technique for the method, the results and their clinical significance is demonstrated. The value of this method is compared with traditional ventriculography and with computer tomography without the use of contrast medium. It is shown that the technique represents an important extension of the scope of computer tomography.

1982-04-01

254

Computed tomography in migratory disorders of human brain development  

International Nuclear Information System (INIS)

Computed tomographic findings in developmental brain anomalies are more easily classified when the system used is based on embryogenesis related to morphology. Analysis of computed tomographic findings in a series of 154 patients with brain anomalies (Chiari malformation not included) revealed that specific examples of abnormalities occurring in major stages of brain development may be recognized by computed tomography. This paper deals with a group of patients with abnormalities that reflect a disturbance in neuronal migration. (orig.).

259

'__-_ _! _/_/ _  

Science.gov (United States)

In 1963, Grover and co-workers at the Los Alamos. Scientific. Laboratory ...... and A. P. Watkins. (1986) "The Computation of Compressible ...

260

Computing in high energy physics  

Energy Technology Data Exchange (ETDEWEB)

This book deals with advanced computing applications in physics, and in particular in high energy physics environments. The main subjects covered are networking; vector and parallel processing; and embedded systems. Also examined are topics such as operating systems, future computer architectures and commercial computer products. The book presents solutions that are foreseen as coping, in the future, with computing problems in experimental and theoretical High Energy Physics. In the experimental environment the large amounts of data to be processed offer special problems on-line as well as off-line. For on-line data reduction, embedded special purpose computers, which are often used for trigger applications are applied. For off-line processing, parallel computers such as emulator farms and the cosmic cube may be employed. The analysis of these topics is ...

1986-01-01

261

An Energy-Efficient Resource Allocation Scheme for Mobile Ad Hoc Computational Grids  

British Library Electronic Table of Contents (United Kingdom)

Due to recent advancements in mobile computing and communication technologies, mobile ad hoc computational Grids are emerging as a new computing paradigm, enabling innovative applications through sharing of computing resources among mobile devices without any pre-existing network infrastructure. Energy-efficient resource allocation is one of the key issues in mobile ad hoc computational Grids due to limited battery life of mobile nodes. To reduce energy consumption, we propose a hybrid power-based resource allocation scheme for allocation of interdependent tasks to nodes within mobile ad hoc computational Grid. The basic idea is to exploit dependencies and task type, and allocate interdependent tasks to nodes accessible at minimum transmission power. We also propose a power-based algorithm...

2011-01-01

262

Dosimetry measurements of x-ray and neutron radiation levels near the shuttle and end beam dump at the advanced test accelerator: Beam Research Program  

International Nuclear Information System (INIS)

Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and potentially damaging to instrumentation that may be used for diagnostics. To provide shielding for minimizing the risk of exposure to personnel and ...

263

Dosimetry for Total Skin Electron Beam Therapy in Skin Cancer  

International Nuclear Information System (INIS)

Increasing frequency of skin cancer, mycosis fungoides, Kaposi sarcoma etc, it need to treatment dose planning for total skin electron beam (TSEB) therapy. Appropriate treatment planning for TSEB therapy is needed to give homogeneous dose distribution throughout the entire skin surface. The energy of 6 MeV electron from the 18 MeV medical linear accelerator was adapted for superficial total skin electron beam therapy. The energy of the electron beam was reduced to 4.2 MeV by a 0.5cmx90cmx180cm acryl screen placed in a feet front of the patient. Six dual field beam was adapted for total skin irradiation to encompass the entire body surface from head to toe simultaneously. The patients were treated behind the acryl screen plate acted as a beam scatterer and contained a parallel-plate shallow ion chamber for dosimetry and beam monitoring. During treatment, the patient was placed in six different positions due to be homogeneous dose distribution for whole skin around ...

1992-06-01

264

Dosimetry audit on the accuracy of 192Ir brachytherapy source strength determinations in Sweden  

Energy Technology Data Exchange (ETDEWEB)

The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. The good agreement ...

2007-11-15

265

Cellular dosimetry: Absorbed fractions for monoenergetic electron and alpha particle sources and S-values for radionuclides uniformly distributed in different cell compartments  

Energy Technology Data Exchange (ETDEWEB)

The importance of cellular dosimetry in both diagnostic and therapeutic nuclear medicine is becoming increasingly recognized. Experimental range-energy relations for electrons and alpha particles, along with derived geometric reduction factors, are used to calculate cellular absorbed fractions for these radiations. The resulting absorbed fractions are employed to calculate cellular S-values for several radionuclides. Cellular absorbed fractions for monoenergetic electron sources with energies ranging from 0.1 keV to 1 MeV, distributed uniformly in the source region, are calculated for several target {l_arrow} source combinations including cell{l_arrow}cell, cell{l_arrow}cell surface, nucleus{l_arrow}nucleus, nucleus {l_arrow}cytoplasm and nucleus {l_arrow}cell surface. Similar data are also provided for monoenergetic alpha particle sources with energies ranging from 3 to 10 MeV. S-values are also conveniently tabulated for {sup 32}P, {sup 35}S, {sup 86}Rb, {sup ...

1994-02-01

266

A Glance into the Future of Human Computer Interaction  

CERN Document Server

Computers have a direct impact on our lives nowadays. Human's interaction with the computer has modified with the passage of time as improvement in technology occurred the better the human computer interaction became. Today we are facilitated by the operating system that has reduced all the complexity of hardware and we undergo our computation in a very convenient way irrespective of the process occurring at the hardware level. Though the human computer interaction has improved but it's not done yet. If we come to the future the computer's role in our lives would be a lot more rather our life would be of the artificial intelligence. In our future the biggest resource would be component of time and wasting time for a key board entry or a mouse input would be unbearable so the need would be of the computer interaction environment that along ...

2011-01-01

267

Some studies on physics parameters of Wolsung unit no. 1  

International Nuclear Information System (INIS)

Nuclear physics parameters of the Wolsung CANDU-PHW reactor are computed by use of the PHWCELL computer code that is an improved version of LATREP. The PHWCELL code mainly computes cell parameters of heavy water moderated reactors, and modeling scheme of heavy water reactor cell calculations has been developed with the PHWCELL computer code. The reactor operating conditions considered in the study are cold zero power (CZP) and hot full power (HFP) with equilibrium poison. The cell parameters are also computed as a function of fuel burnup and the numerical results are compared with the results in PSR of the Wolsung unit and in the previous study. (author).

1980-01-01

268

Numerical Computation of Diffusion on a Surface  

Energy Technology Data Exchange (ETDEWEB)

We present a numerical method for computing diffusive transport on a surface derived from image data. Our underlying discretization method uses a Cartesian grid embedded boundary method for computing the volume transport in region consisting of all points a small distance from the surface. We obtain a representation of this region from image data using a front propagation computation based on level set methods for solving the Hamilton-Jacobi and eikonal equations. We demonstrate that the method is second-order accurate in space and time, and is capable of computing solutions on complex surface geometries obtained from image data of cells.

2005-02-24

269

Computer-aided diagnosis of bone tumours and tumour-like skeletal abnormalities in childhood  

Energy Technology Data Exchange (ETDEWEB)

The method, use and results of computer-aided diagnosis of bone tumours and tumour-like skeletal abnormalities in childhood are described. One hundred and twentyone histologically verified cases were analysed and subjected to computer-aided diagnosis. Statistical methods were used, resulting in an accuracy of 96.7% and 91.7% respectively. In order to obtain additional confirmation of the diagnosis, a so-called growth rate was calculated by the computer. This proved to be a reliable criterion for evaluating the biological behaviour of tumours, irrespective of the histological diagnosis. The reasons for misdiagnosis were discussed. Attention is drawn to the importance of an accurate analysis of the radiographs and its input into the computer.

1982-06-01

270

Comparing Computer Run Time of Building Simulation Programs  

Energy Technology Data Exchange (ETDEWEB)

This paper presents an approach to comparing computer run time of building simulation programs. The computing run time of a simulation program depends on several key factors, including the calculation algorithm and modeling capabilities of the program, the run period, the simulation time step, the complexity of the energy models, the run control settings, and the software and hardware configurations of the computer that is used to make the simulation runs. To demonstrate the approach, simulation runs are performed for several representative DOE-2.1E and EnergyPlus energy models. The computer run time of these energy models are then compared and analyzed.

2008-07-23

271

Centre for Quantum Computation & Communication Technology  

Science.gov (United States)

This is the homepage of "an Australian multi-university collaboration undertaking research on the fundamental physics and technology of building, at the atomic level, a solid state quantum computer in silicon together with other high potential implementations." Although attempts to develop a quantum computer have met with limited success, the centre has substantial resources invested in advancing toward practical uses of quantum computing technology. The site provides a very good introduction to the principles and implications of quantum computing, as well as details about various research projects underway at the Australian universities. Links to conference and journal papers produced by members of the centre, many from 2003, are also provided.

272

BUBL LINK: Computer programming - visual basic  

Wastenet

...BUBL LINK: Computer programming - visual basic BUBL LINK Catalogue of Internet Resources Home | Search | Subject Menus | Countries ...O | P | Q | R | S | T | U | V | W | X | Y | Z Computer programming - visual basic Titles ... Author: Microsoft Subjects: computer programming - visual basic DeweyClass: 005.133 Resource type: software SearchVB....com Subjects: computer programming - visual basic DeweyClass: 005.133 Resource type: index VB Helper Tutorials ...

273

XENON-POISONING COMPUTER  

Science.gov (United States)

A computer was built for use with the NRU reactor to solve the problem of Xe/sup 135/ concentrations. The effect of any changes in reactor on Xe/sup 135/ concentration can be predicted and steps taken to avoid poisoning out. An electromechanical system was used for the computer to avoid the inherent disadvantages that electronic analog computers present for problems of very long solution times. The electromechanical analog computer has a high order of reliability and contains no vaccum tubes, commutators, slip rings, relays, or aluminum electrolytic capacitors. It is insensitive to transient disturbarce. In the event of failure of components or interruption of line voltage, it will retain existing information. The computer was designed for ~ 1% accuracy in Xe/ sup 135/ concentration readings. (W.D.M.)

1958-05-01

274

A network security case study; The Los Alamos National Laboratory integrated computer network  

Energy Technology Data Exchange (ETDEWEB)

This paper reports on a study to validate the Graphical Network Representation (GRPHREP) model which is being conducted on the Los Alamos National Laboratory Integrated Computer Network (ICN). The GRPHREP model is a software system application based on graph theory and object-oriented programming methodologies. It codified the Department of Energy (DOE) Order 5637.1, which is concerned with classified computer secret policy, restrictions, and requirements. The Los Alamos ICN is required to control access to and support large-scale scientific and administrative computing. Thus, large-scale scientific and administrative computing. Thus we felt that this large, complex, and dynamic network would provide a good test for the graphical and functional capabilities of the model. Furthermore, the ICN is composed of multiple partitions that reflect the sensitivity and classification of the ...

1991-01-01

275

Using Multidetector Computed Tomography in a Swine Model to Assess the Effects of Sublingual Nitroglycerin and Intravenous Adenosine on Epicardial Coronary Arteries  

UK PubMed Central (United Kingdom)

This study examines the effects of intravenous infusion of adenosine and sublingual nitroglycerin on coronary angiograms obtained by current-generation multidetector computed tomography. We assessed...Full Text Available

2009-12-01

276

Three dimensional wavefield modeling using the pseudospectral method; Pseudospectral ho ni yoru sanjigen hadoba modeling  

Energy Technology Data Exchange (ETDEWEB)

Discussed in this report is a wavefield simulation in the 3-dimensional seismic survey. With the level of the object of exploration growing deeper and the object more complicated in structure, the survey method is now turning 3-dimensional. There are several modelling methods for numerical calculation of 3-dimensional wavefields, such as the difference method, pseudospectral method, and the like, all of which demand an exorbitantly large memory and long calculation time, and are costly. Such methods have of late become feasible, however, thanks to the advent of the parallel computer. As compared with the difference method, the pseudospectral method requires a smaller computer memory and shorter computation time, and is more flexible in accepting models. It outputs the result in fullwave just like the difference method, and does not cause wavefield numerical variance. As the computation platform, the ...

1997-05-27

277

Technology Strategy Board | Delivering innovation | International programmes | ARTEMIS  

Wastenet

...challenges faced by the industrial sector by implementing a Research Agenda for Embedded Computing Systems. The Artemis JU will manage and co-ordinate open ...5 billion research programme on Embedded Computing Systems. The programme is open to organisations within the EU Member States as well as Associated ...

278

Quantum computing with solids  

Energy Technology Data Exchange (ETDEWEB)

Science and technology could be revolutionized by quantum computers, but building them from solid-state devices will not be easy. Robert W Keyes of IBM's research division outlines the challenges in scaling up the technology from lab experiments to practical devices. (U.K.)

2002-08-01

279

Prevalence of Renal Artery and Kidney Abnormalities by Computed Tomography among Healthy Adults  

UK PubMed Central (United Kingdom)

Background and objectives: Management of incidental renal artery and kidney abnormalities in patients undergoing computed tomography scans is a clinical challenge because their frequency in healthy...Full Text Available

2010-03-01

280

Panel > Cloudenomics 101 What Cloud Computing Really Means for  

Science.gov (United States)

Aug 8, 2011 ... Panel > Cloudenomics 101 What Cloud Computing Really Means for NASA. 11:00 am in Collaboration, LiveCall by Lucas Cioffi (Moderator) ...

281

NASA - NASA COMPUTER ROCKET SCIENCE HELPS DEBAKEY HEART PUMP TEAM  

Science.gov (United States)

Feb 24, 2000 ... NASA computer experts have been using a supercomputer to improve the NASA/ DeBakey miniature heart assist pump, leading to on-going human ...

282

Multilevel support vector regression analysis to identify condition-specific regulatory networks  

UK PubMed Central (United Kingdom)

Motivation: The identification of gene regulatory modules is an important yet challenging problem in computational biology. While many computational methods have been proposed to identify...Full Text Available

2010-06-01

283

Method of pipe whip and impact analyses  

Energy Technology Data Exchange (ETDEWEB)

We successfully reproduce one of the French pipe whip experiments with the computer code WIPS. The WIPS results are in excellent agreement with the experimental data and the French computer code TEDEL. This justifies the use of its pipe element in conjunction with its U-bar element in a simplified method of impact analyses.

1983-11-21

284

Magnetic resonance imaging and computational fluid dynamics (CFD) simulations of rabbit nasal airflows for the development of hybrid CFD/PBPK models  

UK PubMed Central (United Kingdom)

The percentages of total airflows over the nasal respiratory and olfactory epithelium of female rabbits were calculated from computational fluid dynamics (CFD) simulations of steady-state inhalation....Full Text Available

2009-05-01

285

Local design specifications for the CCN security controller (SC)  

Energy Technology Data Exchange (ETDEWEB)

This is a description of the preliminary local design specifications of the Central Computing Network Security Controller. The external interface to the Central Computing Network is not described, but the functions and services to be provided are included as justification for the local design.

1981-04-01

286

Local Spatial Frequency Analysis for Computer Vision  

Science.gov (United States)

Page 1. Mt N Local Spatial Frequency Analysis N for Computer Vision N John Krumm and Steven A. Shafer CMU-RI-TR-90-1 1 JUNO0 8 199 0 ...

1990-05-01

287

Incorporating a Language/Action Design Perspective into a Computer-Based Psychiatric Alerting System  

UK PubMed Central (United Kingdom)

User acceptance of a computer system depends on a number of factors, including broad social and professional concerns regarding the system's impact on the work environment. This observation is especially...Full Text Available

1989-11-08

288

Including Internet insurance as part of a hospital computer network security plan.  

Science.gov (United States)

Cyber attacks on a hospital's computer network is a new crime to be reckoned with. Should your hospital consider internet insurance? The author explains this new phenomenon and presents a risk assessment for determining network vulnerabilities. PMID:11951384

2002-01-01

289

Has general practitioner computing made a difference to patient care? A systematic review of published reports.  

UK PubMed Central (United Kingdom)

OBJECTIVE--To review findings from studies of the influence of desktop computers on primary care consultations. DESIGN--Systematic review of world reports from 1984 to 1994. SETTING--The computerised...Full Text Available

1995-09-30

290

Guidelines on exchangers  

Energy Technology Data Exchange (ETDEWEB)

Experience has shown that a list of tips provides designers and engineers with an effective guide in their areas of duties and concern. This list contains new and rare information on heat exchangers and heat recovery systems. The information presented can be used effectively with personal computers and pocket calculators and also conveniently translated into computer programs and nomographs.

1985-08-01

291

Evaluating Computer Capabilities in a Primary Care Practice-Based Research Network  

UK PubMed Central (United Kingdom)

PURPOSE We wanted to assess computer capabilities in a primary care practice-based research network and to understand how receptive the practices were to new ideas for automation of practice...Full Text Available

2004-09-01

292

Ensemble quantum computing by NMR?spectroscopy  

UK PubMed Central (United Kingdom)

A quantum computer (QC) can operate in parallel on all its possible inputs at once, but the amount of information that can be extracted from the result is limited by the phenomenon of wave function...Full Text Available

1997-03-04

293

Computer-based analysis of Haemophilus parasuis protein fingerprints  

UK PubMed Central (United Kingdom)

AbstractThe present study aimed to compare the whole-cell protein profiles of Haemophilus parasuis field isolates by using a computer-based analysis, and evaluate the...Full Text Available

2004-01-01

294

Computer code analysis of steam generator in thermal-hydraulic test facility simulating nuclear power plant.  

Science.gov (United States)

In the study three loss-of-feedwater type experiments which were preformed with the PACTEL facility has been calculated with two computer codes. The purpose of the experiments was to gain information about the behaviour of horizontal steam generator in a ...

1995-01-01

295

Computer Assisted Video Instruction (CAVI) in an Anesthesia Training Program  

UK PubMed Central (United Kingdom)

For over 20 years advocates of computer assisted instruction (CAI) have been proclaiming impending revolutionary developments in the educational process, yet progress in acceptance has been slow. This...Full Text Available

1983-10-26

296

COMPUTER ECONOMICS OF PHYSICAL COAL CLEANING AND FLUE GAS DESULFURIZATION. FINAL REPORT  

Science.gov (United States)

The report describes a computer model developed by TVA to simulate the performance and determine the economics of coal cleaning, or coal cleaning combined with flue gas desulfurization (FGD), for power plant emission control processes over a wide range of user-specified condition...

297

An Evaluation of a Computer Imaging Program to Prepare Women for Chemotherapy-related Alopecia  

UK PubMed Central (United Kingdom)

ObjectiveThis study was conducted to evaluate a computer-imaging program called HAAIR (Help with Adjustment to Alopecia by Image Recovery) that was developed to provide...Full Text Available

2010-07-01

298

The response of some TL albedo neutron dosimeters  

International Nuclear Information System (INIS)

As part of a general study of personnel neutron dosimetry systems, three British and two German TL albedo dosimeters were compared. They range from simple albedo devices to multi-element devices which detect combinations of incident and albedo neutrons. They were exposed to beams of mono-energetic neutrons, a thermal neutron column and a "2"5"2Cf source. The variation in response with neutron energy above 0.1 MeV was similar for all dosimeters. The resuls show that in general multi-component dosimeters fo not provide enough information to deduce the effective energy of incident neutrons. The choice of single or multi-element dosimeters for particular types of environment is discussed. The Harvey dosimeter has the most acceptable thermal neutron response of the simpler devices. For neutron energies below 0.5 MeV its response varies roughly as the cosine of the angle of incidence but is more complex at higher energies. (author).

299

The integral experiment on beryllium with D-T neutrons for verification of tritium breeding  

Energy Technology Data Exchange (ETDEWEB)

A clean benchmark experiment on beryllium was performed with D-T neutrons at the FNS facility of the Japan Atomic Energy Agency. The main objective was to verify the integral data related to the tritium production on lithium isotopes. Tritium production rates, as well as activation reaction rates were measured inside the beryllium assembly that was shaped as a pseudo-cylindrical slab with an area-equivalent diameter of 628 mm and a thickness of 355 mm. Experimental results were analyzed with a three-dimensional Monte Carlo transport code MCNP-4C and FENDL/MC-2.0, JENDL-3.2/3.3 neutron transport libraries. Evaluation of reaction rates was based on the cross section data taken from the JENDL Dosimetry File and ENDF B-VI data libraries. Analysis shows that all calculation combinations (transport and activation cross section libraries) used for evaluation of reaction rates give data that is agreeable with measured values within 10%.

2007-01-15

300

Spectral energy effects in ESR bone dosimetry: photons and electrons  

International Nuclear Information System (INIS)

The spectral energy-dependence of the radiation-induced ESR signal has been studied in ovine cortical bone. Crushed bone samples were irradiated using photon beams with effective energies in the range from 0.06 to 6 MeV, and electron beams with mean energies in the range from 2 to 10 MeV. The photon and electron data were normalized to a dose to bone of 50 Gy and the results are reported as response relative to the ESR signal for photon irradiation at 1.25 MeV ("6"0Co). The photon irradiation results show that the ESR response is greatest at low energies with a relative value of 1.2 at 0.06 MeV. The relative response decreases, as the energy increases, to approximately 0.85 in the region of 2 to 3 MeV. These variations in the relative ESR responses are significantly less than the ESR energy-dependent responses reported in the literature for human tooth enamel and synthetic hydroxyapatite. An explanation for this difference is offered. For electron beam irradiations, the ESR signal is ...

301

Role of accelerator mass spectrometry in biological dosimetry  

International Nuclear Information System (INIS)

Understanding risks from exposures to carcinogens and other chemicals depends upon measurement of their dose to target tissues and their reactivity with critical macromolecules. The authors have used AMS detection of radio-isotopes to assess doses and reactivities at low, environmentally relevant doses. Several biomedical investigations show the effectiveness of quantification of biologically important events at extremely high sensitivity with AMS. Specifically, they have measured the addition of environmental carcinogens such as 2-amino-3,8-dimethylimidazo[4,5-f]-quinoaxaline (MelQx), a chemical found in cooked food, to DNA at concentrations relevant to human exposure. Other low level detection problems in biology, such as immunoassay assessment of small environmental chemicals, is being developed with attomole sensitivity. AMS also aids the assessment of genotoxic risks from chemicals by quantifying the binding of labeled chemicals to DNA. The very toxic and potent carcinogen, ...

1992-04-05

302

Radiological concepts in radiotherapy  

International Nuclear Information System (INIS)

The atomic explosions in Hiroshima and Nagasaki made the name radiation itself become a nightmare. Notwithstanding this, radiation continued to serve the mankind specially in diagnosis of several human diseases and in the treatment of intractable malignancies. With their latest research tools biologists have now shown a significant shift in the earlier paradigm; even the concept that radiation initiates cancer appears to be no longer tenable. On the contrary, selective radiation doses inhibit growth of cancer cells and radiation in combination with many chemotherapeutic drugs, radiosensitizing chemicals and/or hyperthermia, is emerging as a new modality for cancer treatment which offers high therapeutic advantages. In addition, the deleterious effects of radiation can now be strategically counter poised by the use of many drugs and chemicals. This has been possible by the newer insights gained in the mechanism of biological effects of radiation. The fate of radiation-induced free ...

303

Quantitative assessment of cancer risk from exposure to diesel engine emissions  

Energy Technology Data Exchange (ETDEWEB)

Quantitative estimates of lung cancer risk from exposure to diesel engine emissions were developed using data from three chronic bioassays with Fischer 344 rats. Human target organ dose was estimated with the aid of a comprehensive dosimetry model. This model accounted for rat-human differences in deposition efficiency, normal particle clearance rates, transport of particles to lung-associated lymph nodes, respiration rates, and lung surface area, as well as high-dose inhibition of particle clearance. Recent evidence indicates that the inert carbon core of the diesel particulate matter is likely to be the primary source of carcinogenicity. The epithelial tissue lining the alveoli and lower airways is the primary target site for induction of lung tumors. Dose was therefore based upon the concentration of carbon particulate matter per unit lung surface area. Unit risk estimates were developed using either a time-to-tumor or a linearized multistage model. The unit ...

1993-02-01

304

Preliminary study of the application of natural olivine in Cenozoic dating  

Energy Technology Data Exchange (ETDEWEB)

The study investigated the luminescence behaviour of natural olivine to discuss the potential for Cenozoic (quaternary) dating. The UV-blue thermoluminescence (TL) glow curves of irradiated olivines have a resolved peak at 190 deg. C and other peaks at higher temperature at lower dose levels, and broad signals around 275-310 and 375-400 deg. C at higher dose levels. The UV-blue TL increases with additional laboratory dose to {approx}1.6kGy within a plateau temperature region, suggesting the possibility of dosimetry and Cenozoic dating. Both infrared stimulated luminescence (IRSL) and blue light stimulated luminescence (BLSL) were detected from laboratory-irradiated olivines although the BLSL was weaker than the IRSL. Furthermore, post-BL IRSL was detected but post-IR BLSL was not observed. Therefore, IR stimulation is recommended for optically stimulated luminescence measurements with natural olivine. The growth of the IRSL signal component with doses less than ...

2006-08-15

305

Physics of electron beam therapy  

International Nuclear Information System (INIS)

A book has been written to introduce the physical aspects of the radiotherapy electron beam by presenting a summary of the developments in this field. The first chapter is a brief introduction to the technology of medical accelerators with emphasis on the electron beam production facilities. Chapter 2 describes the interaction processes at the atomic level once the electron beam enters the medium. Chapter 3 is concerned with the various properties of the electron beam purely from the clinical point of view. The electron beam algorithms and models for distribution calculations are covered in Chapter 4 with inclusion of age diffusion and multiple scattering approaches. The factors affecting the beam distribution in a patient, with inhomogeneities, surface irregularities, backscattering etc. are discussed in Chapter 5. The last two chapters are devoted to electron beam dosimetry including various dosimetric methods, specification and measurement of beam energy, ...

306

Pet's research at the SHFJ, Cea, one example: development and validation of a radioligand for the study of the cerebral dopaminergic system; La recherche en TEP au SHFJ, CEA. Un exemple: developpement et validation de radioligands pour l'etude du systeme dopaminergique  

Energy Technology Data Exchange (ETDEWEB)

The aim of this work is the evaluation of biodistribution and radiation dosimetry of a cocaine analog, the N-(3-iodo-prop-2E-enyl)-2beta-carbo-methoxy-3beta-(4-methyl-phenyl) nor-tropane (PE2I), labeled with carbon 11 ([{sup 11}C]PE2I). The [{sup 11}C]PE2I is a selective radioligand for imaging neuronal dopamine transporter (DAT) with positron emission tomography (PET). The DAT is a membrane-bound pre synaptically located protein that regulates the concentration of dopamine at nerve terminals. DAT radioligands are often used to evaluate the progression of Parkinson's disease or the efficiency of neuro-protective therapeutics and, typically, these studies required several successive PET scans. (author)

2005-10-15

307

Measurement of dose-area product in diagnostic radiology as a method of assessing the radiation exposure. (Results, experience, proposals for improvement, recommendations relating to radiological protection). Report of an expert meeting  

International Nuclear Information System (INIS)

The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product measurement in the dosimetry activities in medical ...

308

Irradiation of food  

International Nuclear Information System (INIS)

Processing of food with ionizing radiation is a method suitable to enhance shelf-life and hygienic quality. Up to a dose of 10 kGy the method is considered wholesome. In many countries the practical use of food irradiation is increasing, however, in the Federal Republic of Germany the process is strictly forbidden. Applications and methods for radiation processing of food are compiled, limits and prospects are explained, and advantages and disadvantages are compared with traditional methods. Identification of irradiated foods and dosimetry and process control for radiation processing of food are areas where further research is needed. Continuous processing of particulate foods in bulk is an application where electron accelerators might be profitable. Beam parameters and velocity distribution of food particles in the treatment area can be matched for an effective result. Thus, dose distribution can be adjusted for homogeneous treatment and at the same time radiation ...

309

Facility Effluent Monitoring Plan for Pacific Northwest National Laboratory Balance-of-Plant Facilities  

Energy Technology Data Exchange (ETDEWEB)

The Pacific Northwest National Laboratory (PNNL) operates a number of research and development (R and D) facilities for the Department of Energy on the Hanford Site. According to DOE Order 5400.1, a Facility Effluent Monitoring Plan is required for each site, facility, or process that uses, generates, releases, or manages significant pollutants or hazardous materials. Three of the R and D facilities: the 325, 331, and 3720 Buildings, are considered major emission points for radionuclide air sampling and thus individual Facility Effluent Monitoring Plans (FEMPs) have been developed for them. Because no definition of ''significant'' is provided in DOE Order 5400.1 or the accompanying regulatory guide DOE/EH-0173T, this FEMP was developed to describe monitoring requirements in the DOE-owned, PNNL-operated facilities that do not have individual FEMPs. The remainder of the DOE-owned, PNNL-operated facilities are referred to as Balance-of-Plant (BOP) ...

1999-04-02

310

Extremely low frequency electric and magnetic fields and cancer: A literature review  

Energy Technology Data Exchange (ETDEWEB)

Epidemiologic studies suggest a weak link between occupational or residential exposure to extremely low frequency electromagnetic fields and cancer, especially tumors of the central nervous and hematopoietic systems. This report discusses these studies with reference to basic research on ELF EMF bioeffects relevant to cancer-promoting mechanisms. Many of the studies suggest a possible interaction of ELF EMF with the immune system, endocrine system, or growth-regulatory signals and morphogenic movements that involve calcium flux through cell membranes. Many bioeffects have been reported only with certain specific combinations of frequency, amplitude, and orientation of the EMF signal with respect to the geomagnetic field. The possibility of signal-specific effects raises a complication in dosimetry for both epidemiologic and experimental studies since ELF EMF effects may not be directly related to field strength. The report concludes with a discussion of design ...

1989-12-01

311

Dosimetry in dental radiology. Dentascan spiral CT versus panoramic radiography; Dosimetria nella radiologia odontostomatologica: confronto tra tomografia computerizzata spirale e ortopantomografia  

Energy Technology Data Exchange (ETDEWEB)

The study compares the doses absorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations. [Italian] Questo lavoro intende confrontare le dosi assorbite nel distretto dento-mascellare, con le due principali tecniche utilizzate in questo campo: TC spirale e ortopantomografia. Emerge come l'esame panoramico delle arcate dentarie eseguito con l'ortopantomografo comporti la'ssorbimento di dosi inferiori rispetto a quelle dell'esame TC spirale con programma Dentascan. Questi dati, pur essendo soggetti a variabilita' dovuta alla strumentazione utilizzata, ...

1999-05-01

312

Dosimetry characterization of $^{32}$P intravascular brachytherapy source wires using Monte Carlo codes PENELOPE and GEANT4  

CERN Document Server

Monte Carlo calculations using the codes PENELOPE and GEANT4 have been performed to characterize the dosimetric parameters of the new 20 mm long catheter based $^{32}$P beta source manufactured by Guidant Corporation. The dose distribution along the transverse axis and the two dimensional dose rate table have been calculated. Also, the dose rate at the reference point, the radial dose function and the anisotropy function were evaluated according to the adapted TG-60 formalism for cylindrical sources. PENELOPE and GEANT4 codes were first verified against previous results corresponding to the old 27 mm Guidant $^{32}$P beta source. The dose rate at the reference point for the unsheathed 27 mm source in water was calculated to be $0.215 \\pm 0.001$ cGy s$^{-1}$ mCi$^{-1}$, for PENELOPE, and $0.2312 \\pm 0.0008$ cGy s$^{-1}$ mCi$^{-1}$, for GEANT4. For the unsheathed 20 mm source these values were $0.2908 \\pm 0.0009$ cGy s$^{-1}$ mCi$^{-1}$ and $0.311 \\pm 0.001$ cGy s$^{-1}$ mCi$^{-1}$, ...

2003-01-01

313

Dosimetric properties of an applicator system for intraoperative electron-beam therapy utilizing a Clinac--18 accelerator  

International Nuclear Information System (INIS)

A prototype electron applicator system providing circular and rectangular fields for use in intraoperative electron beam therapy with a Varian Clinac 18 linear accelerator has been fabricated. The dosimetric properties of this system for a variety of electron-beam energies, applicator sizes, and x-ray collimator settings was documented. Significant findings include: (a) surface dose values are in excess of 90% for electron energies of 12 MeV and above; (b) for the 18-MeV beam, the deepest depth where the central axis dose is 90% of its maximum value is in excess of 50 mm for circular applicators whose diameters are in excess of 5 cm; and (c) the treatment time to deliver 1000 rads ''given dose'' (at a given dose rate of 300 MU/min) is on the order of 3--4 min. Cross-field behavior is acceptable for the intended application and x-ray contamination is less than 4% for any applicator/electron energy combination. A system for irregular field blocking and TLD verification ...

314

Development of real time personal neutron dosimeter with two silicon detectors  

Energy Technology Data Exchange (ETDEWEB)

The personal neutron dosimetry becomes more important with the increasing use of nuclear and accelerator facilities. The solid state track detector, film badge and thermo-luminescent dosimeter have widely been used as passive-type personal neutron dosimeters, but the real-time neutron dosimeter is strongly needed. A real time personal dosimeter which could give neutron dose equivalent over wide energy range from thermal to 10 odd MeV by using two neutron sensors has been developed by our group. For practical commercial product, some changes from these prototype sensors have recently been done by Fuji Electric Co. Ltd. The purpose of this work is the final performance test of the dosimeter just before sale. We checked again about the sensitivity in the monoenergetic neutron field from 8 keV to 15 MeV and in the neutron fields around a few accelerator facilities. (author)

1997-07-01

315

Development of radiological emergency preparedness and biological dosimetry technology  

Energy Technology Data Exchange (ETDEWEB)

Large-scale field tracer experiments have been conducted on Ulchin and Wolsung nuclear sites for the purpose of validating FADAS and of analyzing the environmental characteristics around the nuclear site. The most influential factor in atmospheric dispersion is the meteorological condition. During the experiment, meteorological data were measured on the release point and the selected positions among sampling points. Once radioactive materials are released to the atmosphere, members of public may be exposed through the environmental media such as air, soil and foods. Therefore, to protect the public, adequate countermeasures should be taken at due time for those exposure pathways. Both processes of justification and optimization are applied to a countermeasure simultaneously for decision-making. The work scope of biological research for the radiation protection had contained the search of biological microanalytic methods for the assessment of health effect by radiation and toxic agents, ...

1999-04-01

316

DOE personnel neutron dosimetry evaluation and upgrade program  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. An Effective Dose Equivalent System is being developed to provide guidance in ...

1988-10-01

317

Comparison of radon exposure assessment results: {sup 210}Po surface activity on glass objects vs. contemporary air radon concentration  

Energy Technology Data Exchange (ETDEWEB)

Radon exposure assessment in case-control studies on radon and lung cancer is generally based on contemporary radon concentration measurements, which can be affected by significant changes in the building structures or in living habits. Another method to estimate the radon exposure of the subjects is the recently developed retrospective dosimetry technique based on the {sup 210}Po surface activity from glass objects. In order to compare the results obtained by the two methods, a study has been carried out in a sample of 26 dwellings in Rome, with radon concentration values ranging from 28 to 623 Bq m{sup -3}. Retrospective detectors based on CR-39 and LR 115 were exposed on 50 glass objects in bedrooms and living rooms. The correlation factor between the two sets of data, after removing six extreme values, is 0.67, which is similar to results obtained in other validation studies of similar sample size. The correlation increases to 0.83 if the 21 objects exposed in ...

2003-06-01

318

Characterization of Radiation Instruments at the Summit of Mt. Fuji  

International Nuclear Information System (INIS)

The opportunity of exposure to high-energy radiation up to GeV is increasing as in civilian aircrafts and at particle accelerators. The transport of such energetic particle is still difficult to describe precisely and thus verification by measurement using a well characterized instrument is indispensable for reliable dosimetry. However, no reference calibration field has been established for the high-energy range. We thus propose to use a facility at the summit of Mt. Fuji (3776 m in altitude; N35.36o, E138.73o), the highest place in Japan, for characterization of radiation instruments that are possibly used in high-energy radiation fields. For demonstration of the effectiveness, two moderator-type neutron monitors (NCN1 and WENDI-II) having different energy response functions were employed for cosmic-ray neutron measurements in the summer of 2009. In comparison with numerically simulated values, it was found that the extended energy neutron monitor (WENDI-II) has ...

2010-12-01

319

Analysis on Dose Distribution in Heterogeneous Condition for Narrow 6 MV X-ray Beams  

International Nuclear Information System (INIS)

Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous condition since the GAFCHROMICat..EBT film is composed of tissueequivalent ...

2010-10-01

320

APMP/TCRI key comparison report of measurement of air kerma for medium-energy x-rays (APMP.RI(I)-K3)  

Energy Technology Data Exchange (ETDEWEB)

The APMP/TCRI Dosimetry Working Group performed the APMP.RI(I)-K3 key comparison of measurement of air kerma for medium-energy x-rays (100 kV to 250 kV) between 2000 and 2003. In total, 11 institutes took part in the comparison, among which 8 were APMP member laboratories. Two commercial cavity ionization chambers were used as transfer instruments and circulated among the participants. All the participants established the 100 kV, 135 kV, 180 kV and 250 kV x-ray beam qualities equivalent to those of the BIPM. The results showed that the maximum difference between the participants and the BIPM in the medium-energy x-ray range, evaluated using the comparison data of the linking laboratories ARPANSA and PTB, is less than 1.4%. The degrees of equivalence between the participants are presented and this comparison confirms the calibration capabilities of the participating laboratories. (authors)

2008-10-15

321

AIDE: internal dosimetry software.  

Science.gov (United States)

AIDE (Activity and Internal Dose Estimates) is a software for calculating activities in compartments and committed doses due to occupational exposures, and for performing intake and dose estimates using bioassay data. It has been continuously developed and tested for more than 20 years. Its calculation core has been applied in several situations, like performing all dose estimates due to (137)Cs intakes, which occurred during the Goiania accident in 1987; performing quality assurance of the ICRP Task Group on Dose Calculations regarding calculations of activities in compartments and generation of dose coefficients for adults due to intakes by inhalation, ingestion and injection of several radionuclides; and producing the tables of activities in compartments and dose coefficients using the NCRP Wound Model for the NCRP report. It provides several capabilities like performing calculations using modified Human Respiratory Tract Model parameters for the mechanical transport, blood ...

2008-03-12

322

A water calorimeter for high energy x-rays and electrons  

CERN Document Server

The current primary standards at NPL for the measurement of absorbed dose to water in high energy photon and electron beams are graphite calorimeters. However, the quantity of interest in radiation dosimetry is absorbed dose to water. Therefore, a new absorbed dose to water standard based on water calorimetry has been developed for use in high energy photon and electron beams. The calorimeter operates at 4 deg C, with temperature control being provided by liquid cooling. The sealed glass inner vessel of the calorimeter was designed to minimise the effect of non-water materials on the measurement of absorbed dose. The temperature sensing thermistor probes were designed and constructed so that glass is the only material in contact with high purity water inside the vessel. Initial measurements of absorbed dose to water made in 6, 10, and 19 MV photons, and 16 MeV electrons agreed, within the measurement uncertainties of approximately 1.5% (95% c.l.), with those ...

2000-01-01

323

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

Science.gov (United States)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. Supported by National Natural Science Foundation of China (10475112), Western Light Foundation of Chinese Academy of Sciences of ...

2008-05-01

325

Towards a computational theory of experience  

British Library Electronic Table of Contents (United Kingdom)

A standing challenge for the science of mind is to account for the datum that every mind faces in the most immediate - that is, unmediated - fashion: its phenomenal experience. The complementary tasks of explaining what it means for a system to give rise to experience and what constitutes the content of experience (qualia) in computational terms are particularly challenging, given the multiple realizability of computation. In this paper, we identify a set of conditions that a computational theory must satisfy for it to constitute not just a sufficient but a necessary, and therefore naturalistic and intrinsic, explanation of qualia. We show that a common assumption behind many neurocomputational theories of the mind, according to which mind states can be formalized solely in terms of instan...

2011-01-01

326

The EMSL Collaboratory  

Science.gov (United States)

sharing data and computational resources, and accessing information in digital libraries." Bill Wulf (1989) In a Collaboratory, the presentation/meeting concept embodied...

2011-10-07

327

System integration of pattern recognition, adaptive aided, upper limb prostheses  

Science.gov (United States)

The requirements for successful integration of a computer aided control system for multi degree of

1975-01-01

328

Stochastic Modelling of Seafloor Morphology  

Science.gov (United States)

... elements of the parameter covariance matrix computed from the partial derivative matrix and Vpqrs(',I). We also calculate ...

1990-06-01

329

Shuttle Data Center File-Processing Tool in Java  

Science.gov (United States)

A Java-language computer program has been written to facilitate mining of data in files in the

2006-01-01

330

Quantum-dot computing  

Energy Technology Data Exchange (ETDEWEB)

A quantum computer would put the latest PC to shame. Not only would such a device be faster than a conventional computer, but by exploiting the quantum-mechanical principle of superposition it could change the way we think about information processing. However, two key goals need to be met before a quantum computer becomes reality. The first is to be able to control the state of a single quantum bit (or 'qubit') and the second is to build a two-qubit gate that can produce 'entanglement' between the qubit states. (U.K.)

2003-10-01

331

Probabilistic Simulation for Nanocomposite Characterization Developed and Included in the Computer Code ICAN/JAVA  

Science.gov (United States)

A unique mechanistic method has been developed at the NASA Glenn Research Center to

2008-01-01

332

Preparation of Papers for AIAA Technical Conferences  

Science.gov (United States)

The estimated parameter covariance matrix is computed from8. ) ( ) 1. 2. T. T. ( ) ( )(. ?. ?. ?. Cov. E. ??. . ?. = . ? ? ? ? ?. ?. = ?. ?. ? ...

333

Physical and Computational Investigation of the Wall Pressure ...  

Science.gov (United States)

... Although other authors had made cross-spectral density measurements, Corcos pointed to the importance of this function as indicative of the true ...

1990-04-26

334

Optimization of Coatings for the M205 Non Metallic Cartridge ...  

Science.gov (United States)

... Descriptors : *PROTECTIVE COATINGS, *WATER REPELLENTS, *COMBUSTIBLE CARTRIDGE CASES, COMPUTER PROGRAMS, SOLVENTS ...

1974-06-01

335

Nuclear design analysis of wolsung-1 CANDU-PHW nuclear generating station  

International Nuclear Information System (INIS)

A combination of computer codes such as LATREP, HWRAXAV and CITATION is utilized in an attempt to analyze the nuclear design characteristics of the CAXDU-PHWR of the Wolsung Unit 1. The major nuclear properties to be computed are the lattice properties of CANDU fuel channel and the core channel power distribution. The computed results are compared with the preliminary safety reports documentation for the Wolsung reactor. The observed discrepancies between our computations and the preliminary safety reports values are discussed in terms of incomplete information on the description of the core configuration in the preliminary safety reports and the different calculation methods. (author).

1978-01-01

336

NASTRAN nonlinear dynamic transient accident analysis for FFTF reactor component  

International Nuclear Information System (INIS)

... computer calculations fftf reactor nonlinear problems reactor accidents reactor

1976-11-14

337

Models for Work Backlogs at Computers that Time-Share ...  

Science.gov (United States)

... DATA PROCESSING TERMINALS, *REMOTE TERMINALS, DATA PROCESSING, STOCHASTIC PROCESSES, QUEUEING THEORY, TIME ...

1977-07-01

338

MER-DIMES : a planetary landing application of computer vision  

Science.gov (United States)

During the Mars Exploration Rovers (MER) landings, the Descent Image Motion Estimation System

2005-01-01

339

MAGMA: A Liquid Software Approach to Fault Tolerance ...  

Science.gov (United States)

... MAGMA © : A LIQUID SOFTWARE APPROACH TO FAULT TOLERANCE, COMPUTER NETWORK SECURITY, AND SURVIVABLE NETWORKING ...

2001-12-01

341

Integrated photonic qubit quantum computing on a superconducting chip  

International Nuclear Information System (INIS)

We study a quantum computing system using microwave photons in transmission line resonators on a superconducting chip as qubits. We show that linear optics and other controls necessary for quantum computing can be implemented by coupling to Josephson devices on the same chip. By taking advantage of the strong nonlinearities in Josephson junctions, photonic qubit interactions can be realized. We analyze the gate error rate to demonstrate that our scheme is realistic even for Josephson devices with limited decoherence times. As a conceptually innovative solution based on existing technologies, our scheme provides an integrated and scalable approach to the next key milestone for photonic qubit quantum computing.

2010-06-01

342

HVDC cable design logic for digital computers  

Energy Technology Data Exchange (ETDEWEB)

The design of High-Voltage, Direct-Current transmission cables insulated with oil-impregnated cellulose paper is constrained by the maximum temperature and the maximum steady-state and transient stresses (voltage gradients) that the cable insulation can reliably withstand over the desired operating lifetime. Because the electrical stresses in the insulation are related in a very complex fashion to temperature, applied voltage and cable geometry, iterative techniques are required to compute the values of these stresses. Digital computers are ideally suited for these iterative techniques. This paper presents the principal equations and logic needed to develop suitable computer programs.

1992-10-01

347

Computer code development for pipe whip and impact analysis. Progress report for year 2. Load Combination Program. Volume 2  

Energy Technology Data Exchange (ETDEWEB)

A progress report is presented on development of the WIPS computer code, a special purpose code for analysis of whip and impact in nuclear power piping. The computer code and final report are expected to be complete in December 1981. This progress report is an incomplete version of the final report, representing approximately 40% of the volume of the final report. Some sections in the report are complete, some are partially complete, and others are omitted. The report is intended to inform prospective WIPS users of the procedures, theories, and documentation standards which will be used for the computer code and the final report.

1980-12-01

348

Computational Simulation - NASA Technical Report Server (NTRS)  

Science.gov (United States)

the progressive simplification of composite sandwich panels. The equations ... The thermal and structural behavior of composite sandwich panels with a ...

349

Algorithm for WZW fusion rules: A proof  

Energy Technology Data Exchange (ETDEWEB)

A proof is given for a simple algorithm for the computation of fusion rules in Wess-Zumino-Witten (WZW) models. (orig.).

1990-05-17

350

A Simulation Model for Estimating Airport Terminal Area ...  

Science.gov (United States)

... AIR TRAFFIC, TERMINAL FLIGHT ... FLIGHT, RANDOM VARIABLES, STOCHASTIC PROCESSES ... COMPUTER PROGRAMS, QUEUEING THEORY. ...

1971-05-01

351

Temperature coefficient in D_2O moderated reactor (Wolsung Unit 1)  

International Nuclear Information System (INIS)

The temperature coefficient has been investigated on the Wolsung nuclear power reactor, in which fuel is natural uranium dioxide and moderator heavy water. The numerical computations are carried out in terms of changes of the effective neutron multiplication factor with respect to fuel, moderator, and coolant temperatures. Those results are compared with the computed values of temperature coefficient based on the LATREP computer code. (author).

1977-01-01

352

Personal computers restructuring tomorrow's nets  

Energy Technology Data Exchange (ETDEWEB)

Discusses alternative futures for distributing future personal computers, via data communications networks. The author scans and extrapolates some of the advances for impacting the emerging future of information utilities now sprouting up thoroughout the world. In particular he looks at the future of personal computers in the field of artificial intelligence,, for expert knowledge-based systems.

1982-01-01

353

New method for computing quark propagators in quenched quantum chromodynamics  

Energy Technology Data Exchange (ETDEWEB)

Generalization of the alternate directions implicit technique is used to compute the pion propagator in quenched QCD on a lattice. The full four-dimensional problem is reduced to a series of partly decoupled two-dimensional inversions. Chiral properties of the theory computed in this approach agree with those found using other methods.

1986-05-01

354

Microsoft Word - postpn270.doc  

Wastenet

protect digital information, from personal details held on a computer to financial details transmitted over the Internet. Encryption ...in connection with electronic data (Box 2), whether stored on a computer or transmitted over an unsecured network such as ...Encryption tools (usually in the form of computer programs or software) are widely available

355

Knowledge-based image analysis: some aspects on the analysis of images using other types of information  

Energy Technology Data Exchange (ETDEWEB)

The computer vision approach to image analysis is discussed from two aspects. First, this approach is constrasted to the pattern recognition approach. Second, how external knowledge and information and models from other fields of science and engineering can be used for image and scene analysis is discussed. In particular, the connections between computer vision and computer graphics are pointed out.

1982-01-01

356

Embedded computer systems for control applications in EBR-II  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to describe the embedded computer systems approach taken at Experimental Breeder Reactor II (EBR-II) for non-safety related systems. The hardware and software structures for typical embedded systems are presented The embedded systems development process is described. Three examples are given which illustrate typical embedded computer applications in EBR-II.

1993-01-01

357

Efficient higher-order derivatives of the hypergeometric function.  

Energy Technology Data Exchange (ETDEWEB)

Various physics applications involve the computation of the standard hypergeometric function {sub 2}F{sub 1} and its derivatives. Because it is not an intrinsic in the common programming languages, automatic differentiation tools will either differentiate through the code that computes {sub 2}F{sub 1} if that code is available or require the user to provide a hand-written derivative code. We present options for the derivative computation in the context of an ionization problem and compare the approach implemented in the Diamant library to standard methods.

2008-01-01

358

Construction of a data analyzer computer program for neutron activation analysis  

International Nuclear Information System (INIS)

A new software for neutron activation analysis was designed, built and implemented on a desktop computer using Visual Basic 6.0 program. The construction of this data analyzer computer program is described. The new software deals with peak reports resulting from Gammaplus software with minimum interference from the user in order to save time, manpower and minimize human errors. Its ability to find the concentrations of chemical elements within samples is proven to be fast, reliable and user friendly. (author)

359

Computing Networks: A General Framework to Contrast Neural and Swarm Architectures  

CERN Document Server

Computing Networks (CNs) are defined. These are used to generalize neural and swarm architectures, namely artificial neural networks, ant colony optimization, and particle swarm optimization. The description of these architectures as CNs allows their comparison, distinguishing which properties enable them to perform complex computations and exhibit complex cognitive abilities. In this context, the most relevant characteristics of CNs are the existence multiple dynamical and functional scales.

2010-01-01

360

Computer tomography used in tumour diagnosis in children  

Energy Technology Data Exchange (ETDEWEB)

Computer tomography used in the diagnosis of tumours is described in the light of particularly great diagnostic difficulties in children. Computer tomography was applied in 12 cases. A high diagnostic value of this method was demonstrated, which makes possible a more accurate diagnosis of the position of the tumour, its size, and expanding tendency. The possibility of estimating healthy tissues and organs, and those with pathological changes on the basis of differences in their density with a detection threshold at 0.5% density difference facilitates not infrequently preoperative diagnosis raising the value of the method.

1981-01-01

361

Computer analysis and control for nondestructive gamma scanning of LMFBR fuel pins  

International Nuclear Information System (INIS)

A program to modernize existing computer control and data analysis in a precision gamma-scanning system is described. This involves interfacing a new computer-based multichannel analyzer to existing equipment through a CAMAC system with an intelligent crate controller and writing software for scan control and data reduction. Both hardware and software requirements are discussed. 6 figures.

362

Computer Recycling  

Wastenet

... For more information regarding computer recycling visit www.recyclenow.com For further information on Recycling click on the links below Aluminium Recycling Charity Recycling Computer Recycling Clothes Recycling Ink Cartridge Recycling Local Recycling Home Composting Glass Recycling Mobile Phone Recycling Oil Recycling Plastic Recycling Recycling Bins ...

363

Closure of Off-Site FTP  

CERN Multimedia

To reduce the number of regular break-ins on CERN machines due to passwords exposed on the network in clear text, OFF-SITE FTP ACCESS TO CERN WILL BE BLOCKED in the CERN firewall from: Tuesday 20th January 2004 If you use ftp to access CERN computers from outside CERN then please see the link below for alternative access means and further advice: http://cern.ch/security/ftp Denise Heagerty, CERN Computer Security officer, Computer.Security@cern.ch

2004-01-01

364

Closure of Off-Site FTP  

CERN Document Server

To reduce the number of regular break-ins on CERN machines due to passwords exposed on the network in clear text, OFF-SITE FTP ACCESS TO CERN WILL BE BLOCKED in the CERN firewall from: Tuesday 20th January 2004 If you use ftp to access CERN computers from outside CERN then please see the link below for alternative access means and further advice: http://cern.ch/security/ftp Denise Heagerty, CERN Computer Security officer, Computer.Security@cern.ch

2003-01-01

365

Business perspective for information technology  

Energy Technology Data Exchange (ETDEWEB)

Increasingly, utility organizations recognize the value of sharing data and applications among their computing environments. A typical utility`s computing environment may consist of disparate computer platforms. The focus of this paper is to highlight importance of a documented information technology architecture for identifying business perspectives for interoperability, and to brief utility management about the Electric Power Research Institute`s (EPRI) accomplishment along these same lines.

1995-10-01

366

2D cavity grid quantum computing  

Energy Technology Data Exchange (ETDEWEB)

We propose a novel scheme for scalable solid state quantum computing, where superconducting microwave transmission line resonators (cavities) are arranged in a two-dimensional grid on the surface of a chip, coupling to superconducting qubits (charge or flux) at the intersections. We analyze how tasks of quantum information processing can be implemented in such a topology, including efficient two-qubit gates between any two qubits on the grid and elements of fault-tolerant computation.

2008-07-01

367

High-speed wide area, data intensive computing: A Ten Year Retrospective  

Energy Technology Data Exchange (ETDEWEB)

Modern scientific computing involves organizing, moving, visualizing, and analyzing massive amounts of data from around the world, as well as employing large-scale computation. The distributed systems that solve large-scale problems will always involve aggregating and scheduling many resources. Data must be located and staged, cache and network capacity must be available at the same time as computing capacity, etc. Every aspect of such a system is dynamic: locating and scheduling resources, adapting running application systems to availability and congestion in the middleware and infrastructure, responding to human interaction, etc. The technologies, the middleware services, and the architectures that are used to build useful high-speed, wide area distributed systems, constitute the field of data intensive computing. This paper explores some of the history and future directions of that field.

1998-05-01

368

Government-industry-education collaboration for intelligent tutor computer labs  

Energy Technology Data Exchange (ETDEWEB)

Through the dedicated collaborative efforts of many individuals interested in supporting local education, computer laboratories were established at two urban high schools. The purchasing and implementation of the project was handled by the Alliance for Education, a local non-profit education advocate. Funds were supplied by the Air Force as part of a 3-year research activity utilizing artificial intelligence technology to tutor 9th grade students. NCR (now AT7T Global Information Solutions) corporate leaders provided the computers and network equipment at a considerable savings to the project. Each lab is a state-of-the-art facility with air-conditioning, carpeting, special computer tables, computer projection screens, and on-site technical support. Student and teacher enthusiasm toward the project has been gratifying and quantitative results are currently being evaluated for both attitude, skills, and ...

1994-12-31

369

Constrained information maximization by free energy minimization  

British Library Electronic Table of Contents (United Kingdom)

In this paper we introduce free energy-based methods to constrain mutual information maximization, developed to realize competitive learning. The new method is introduced to simplify the computational procedures of mutual information and to improve the fidelity of representation and to stabilize learning. First, the free energy is effective in simplifying the computation procedures of mutual information because we need not directly compute mutual information, which needs heavy computation, but only deals with partition functions. With partition functions, computational complexity is significantly reduced. Second, fidelity to input patterns can be improved because training errors between input patterns and connection weights are implicitly incorporated. This means that mutual information is...

2011-01-01

370

A Worst-case Bound for Topology Computation of Algebraic Curves  

CERN Document Server

Computing the topology of an algebraic plane curve $\\mathcal{C}$ means to compute a combinatorial graph that is isotopic to $\\mathcal{C}$ and thus represents its topology in $\\mathbb{R}^2$. We prove that, for a polynomial of degree $n$ with coefficients bounded by $2^\\rho$, the topology of the induced curve can be computed with $\\tilde{O}(n^8(n+\\rho^2))$ bit operations deterministically, and with $\\tilde{O}(n^8\\rho^2)$ bit operations with a randomized algorithm in expectation. Our analysis improves previous best known complexity bounds by a factor of $n^2$. The improvement is based on new techniques to compute and refine isolating intervals for the real roots of polynomials, and by the consequent amortized analysis of the critical fibers of the algebraic curve.

2011-01-01

371

Models of continuous-variable quantum computing  

Energy Technology Data Exchange (ETDEWEB)

We discuss strictly efficient models for measurement-based quantum computing using physical continuous variables, such as field modes of light. Such measurement-based quantum computing (MBQC) provides a promising paradigm for quantum computation as it does not require performing unitary gates during the computation, but rather appropriate readout. Here, we introduce novel schemes for which the resource state can be reasonably and efficiently prepared, and which notably do not require having infinite squeezing or mean energy available. What is more, error correction techniques are implementable, as the logical information is stored in finite-dimensional objects grasping correlations of the quantum states. Using the ideas of computational tensor networks we discuss how to sequentially prepare suitable physical resource states with cavity QED or with non-linear optics and how to ...

2009-07-01

372

Computed Tomography diagnosis of skeletal involvement in multiple myeloma  

International Nuclear Information System (INIS)

The authors assess the role of Computed Topography in the diagnosis and management of multiple myeloma (MM) and investigate if Computed Tomography findings can influence the clinical approach, prognosis and treatment. 273 multiple myeloma patients submitted to Computed Tomography June 1994, to December, 1996. The patients were 143 men and 130 women (mean age: 65 years): 143 were stage I, 38 stage II and 92 stage III according to Durie and Salomon's clinical classification. All patients were submitted to blood tests, spinal radiography and Computed Tomography, the latter with serial 5-mm scans on several vertebral bodies. Computed Tomography despicted vertebral arch and process involvement in 3 cases with the vertebral pedicle sign. Moreover, Computed Tomography proved superior to radiography in showing the spread of myelomatous masses into the soft tissues in a ...

1994-06-01

373

Improved eddy-current inspection for steam generator tubing  

Energy Technology Data Exchange (ETDEWEB)

Computer programs have been written to allow the analysis of different types of eddy-current probes and their performance under different steam generator test conditions. The probe types include the differential bobbin probe, the absolute bobbin probe, the pancake probe and the reflection probe. The generator test conditions include tube supports, copper deposits, magnetite deposits, denting, wastage, pitting, cracking and IGA. These studies are based mostly on computed values, with the limited number of test specimens available used to verify the computed results. The instrument readings were computed for a complete matrix of the different test conditions, and then the test conditions determined as a function of the readings by a least-squares technique. A comparison was made of the errors in fit and instrument drift for the different probe types. The computations of the change in ...

1989-01-01

374

FY05-FY06 Advanced Simulation and Computing Implementation Plan, Volume 2  

Energy Technology Data Exchange (ETDEWEB)

The Stockpile Stewardship Program (SSP) is a single, highly integrated technical program for maintaining the safety and reliability of the U.S. nuclear stockpile. The SSP uses past nuclear test data along with future non-nuclear test data, computational modeling and simulation, and experimental facilities to advance understanding of nuclear weapons. It includes stockpile surveillance, experimental research, development and engineering programs, and an appropriately scaled production capability to support stockpile requirements. This integrated national program will require the continued use of current facilities and programs along with new experimental facilities and computational enhancements to support these programs. The Advanced Simulation and Computing program (ASC) is a cornerstone of the SSP, providing simulation capabilities and computational resources to support the annual stockpile assessment ...

2004-07-19

375

Accurate, stable, explicit, parabolized navier-stokes solver for high speed flows  

Energy Technology Data Exchange (ETDEWEB)

A stable, accurate, and efficient implementation of MacCormack's explicit algorithm for the Parabolized Navier-Stokes equations is demonstrated. The familiar problem of decoding the conservative axial flux vector is solved, resulting in accurate, smooth dependent variable profiles through the viscous-layer sonic line. Source terms due to transformation of the parabolized governing equations into the computational plane and the equations into the computational plane and the resulting metric differencing have been identified and eliminated through inclusion of appropriate geometric conservation law terms. Test cases computed include two- and three-dimensional supersonic and hypersonic flow at laminar and turbulent Reynolds numbers. The computed results demonstrate very good agreement with experiment and with solutions of the full Navier-Stokes equations. Computational times ...

1986-01-01

376

Search Efficiency in Indexing Structures for Similarity Searching  

CERN Document Server

Similarity searching finds application in a wide variety of domains including multilingual databases, computational biology, pattern recognition and text retrieval. Similarity is measured in terms of a distance function edit distance in general metric spaces, which is expensive to compute. Indexing techniques can be used reduce the number of distance computations. We present an analysis of various existing similarity indexing structures for the same. The performance obtained using the index structures studied was found to be unsatisfactory . We propose an indexing technique that combines the features of clustering with M tree(MTB) and the results indicate that this gives better performance.

2004-01-01

377

Scaling and performance of a 3-D radiation hydrodynamics code on message-passing parallel computers: final report  

Energy Technology Data Exchange (ETDEWEB)

This report details an investigation into the efficacy of two approaches to solving the radiation diffusion equation within a radiation hydrodynamic simulation. Because leading-edge scientific computing platforms have evolved from large single-node vector processors to parallel aggregates containing tens to thousands of individual CPU's, the ability of an algorithm to maintain high compute efficiency when distributed over a large array of nodes is critically important. The viability of an algorithm thus hinges upon the tripartite question of numerical accuracy, total time to solution, and parallel efficiency.

1999-10-28

378

SIMON Host Computer System requirements and recommendations  

Energy Technology Data Exchange (ETDEWEB)

Development Service Order {number_sign}90025 requested recommendations for computer hardware, operating systems, and software development utilities based on current and future SIMON software requirements. Since SIMON`s main objective is to be dispatched on missions by an operator with little computer experience, ``user friendly`` hardware and software interfaces are required. Other design criteria include: a fluid software development environment, and hardware and operating systems with minimal maintenance requirements. Also, the hardware should be expandable; extra processor boards should be easily integrated into the existing system. And finally, the use of well established standards for hardware and software should be implemented where practical.

1990-11-29

379

Roadmap to the SRS computing architecture  

Energy Technology Data Exchange (ETDEWEB)

This document outlines the major steps that must be taken by the Savannah River Site (SRS) to migrate the SRS information technology (IT) environment to the new architecture described in the Savannah River Site Computing Architecture. This document proposes an IT environment that is {open_quotes}...standards-based, data-driven, and workstation-oriented, with larger systems being utilized for the delivery of needed information to users in a client-server relationship.{close_quotes} Achieving this vision will require many substantial changes in the computing applications, systems, and supporting infrastructure at the site. This document consists of a set of roadmaps which provide explanations of the necessary changes for IT at the site and describes the milestones that must be completed to finish the migration.

1994-07-05

380

RATIO COMPUTER  

Science.gov (United States)

An electronic computer circuit is described for producing an output voltage proportional to the product or quotient of tbe voltages of a pair of input signals. ln essence, the disclosed invention provides a computer having two channels adapted to receive separate input signals and each having amplifiers with like fixed amplification factors and like negatlve feedback amplifiers. One of the channels receives a constant signal for comparison purposes, whereby a difference signal is produced to control the amplification factors of the variable feedback amplifiers. The output of the other channel is thereby proportional to the product or quotient of input signals depending upon the relation of input to fixed signals in the first mentioned channel.

1958-11-11

381

Quantum Computation with Nonlinear Optics  

International Nuclear Information System (INIS)

We propose a scheme of quantum computation with nonlinear quantum optics. Polarization states of photons are used for qubits. Photons with different frequencies represent different qubits. Single qubit rotation operation is implemented through optical elements like the Faraday polarization rotator. Photons are separated into different optical paths, or merged into a single optical path using dichromatic mirrors. The controlled-NOT gate between two qubits is implemented by the proper combination of parametric up and down conversions. This scheme has the following features: (1) No auxiliary qubits are required in the controlled-NOT gate operation; (2) No measurement is required in the course of the computation; (3) It is resource efficient and conceptually simple.

2008-01-15

382

Prediction of the compressive strength of vertebral bodies of the lumbar spine by quantitative computed tomography.  

Science.gov (United States)

The ultimate compressive strength of 36 thoracolumbar vertebrae was determined experimentally. In addition, the trabecular bone mineral content was measured by single energy quantitative computed tomography. The areas of fractured endplates were also determined by computed tomography. The results show that a linear relationship exists between the compressive strength and the product of bone density and endplate area. These data allow an in vivo prediction of vertebral body strength using a noninvasive method with a standard error of estimate amounting to less than 0.95 kN. PMID:3212488

1988-01-01

383

Go vs. no-go - potential and limitations of continuous-variable quantum computing by measurements  

Energy Technology Data Exchange (ETDEWEB)

In this talk, we explore the feasibility of quantum computation using continuous-variable systems by means of local measurements only. In the first part of the talk, we will identify crucial limitations that arise when starting from Gaussian cluster states. This is done by resorting to a Gaussian projected entangled pair picture as well as to notions of continuous-variable quantum repeater networks. In the second part, we look at instances in which these limitations can be overcome, and how suitable encodings of qubits in oscillators and feasible non-Gaussian resource states give rise to universal schemes for quantum computing.

2010-07-01

384

FCR (Fuji Computed Radiography) in neurosurgery  

Energy Technology Data Exchange (ETDEWEB)

As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness.

1988-08-01

385

FCR (Fuji Computed Radiography) in neurosurgery  

International Nuclear Information System (INIS)

As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness. (author).

1988-01-01

386

Computer-aided band gap engineering and experimental verification of amorphous silicon-germanium solar cells  

Energy Technology Data Exchange (ETDEWEB)

A new band gap profile (exponential profile) for the active layer of the a-SiGe:H single junction cell has been designed and experimentally demonstrated. By computer simulations we show how bending the grading of the band gap in the i-layer contributes to the enhancement of the carrier collection, improving the fill factor and efficiency. The differences observed between experiments and simulations are studied using Rutherford Backscattering Spectrometry (RBS). The results highlight weak points during the deposition process, whose control enables us to bring together experimental and computational results.

2004-01-25

387

Computer vision approaches to medical image analysis. Revised papers  

Energy Technology Data Exchange (ETDEWEB)

This book constitutes the thoroughly refereed post proceedings of the international workshop Computer Vision Approaches to Medical Image Analysis, CVAMIA 2006, held in Graz, Austria in May 2006 as a satellite event of the 9th European Conference on Computer Vision, EECV 2006. The 10 revised full papers and 11 revised poster papers presented together with 1 invited talk were carefully reviewed and selected from 38 submissions. The papers are organized in topical sections on clinical applications, image registration, image segmentation and analysis, and the poster session. (orig.)

2006-07-01

388

Computer tomographic demonstration of so-called azygos continuation in the absence of the hepatic segment of the inferior vena cava  

International Nuclear Information System (INIS)

Dilatation of the azygos vein is usually due to increased pressure or flow, rarely is it diopathic. Another cause is so-called continuation of the azygos in cases of absence of the hepatic segment of the inferior vena cava. The method of choice for the investigation of azygos dilatation nowadays is computer tomotgraphy. Anomalies of the inferior vena cava can be recognised in this way unequivocally by a non-invasive method. Computer tomography frequently shows important additional abnormalities (e.g. situs inversus, polysplenia), since it demonstrates all organs situated in the plane of section. (orig.).

389

Computer simulation and scientific visualization  

Energy Technology Data Exchange (ETDEWEB)

The simulation of processes in engineering and the physical sciences has progressed rapidly over the last several years. With rapid developments in supercomputers, parallel processing, numerical algorithms and software, scientists and engineers are now positioned to quantitatively simulate systems requiring many billions of arithmetic operations. The need to understand and assimilate such massive amounts of data has been a driving force in the development of both hardware and software to create visual representations of the underling physical systems. In this paper, and the accompanying videotape, the evolution and development of the visualization process in scientific computing will be reviewed. Specific applications and associated imaging hardware and software technology illustrate both the computational needs and the evolving trends. 6 refs.

1990-01-01

390

Computer modelling for risk assessment of transportation using methods of fuzzy set theory  

International Nuclear Information System (INIS)

Computer software for risks assessment of transportation of important freight has been developed. It incorporates models of transport accidents, including terrorist attacks. These models use, among the others, unput data of cartographic character. Geographical information system technology and electronic maps of an area are involved as an instrument for handling this kind of data. Fuzzy set theory methods as well as standard methods of probability theory have been used for quantitative risk assessment. Fuzzy algebraic operations and their computer realisation are discussed. One preliminary example of risk assessment is described. (authors)

1998-05-10

391

Computer model of high-latitude scintillation. [WBMOD program  

Energy Technology Data Exchange (ETDEWEB)

The DNA Wideband satellite experiment provided extensive data on scintillation produced in high-altitude structured plasmas. A computer program, WBMOD, is being developed to summarize those data in an applications-oriented way. The program contains the phase-screen scattering theory of Rino and a morphological description of ionospheric irregularities (thus far only at auroral latitudes) based on Wideband observations. It permits a user to compute scintillation indices for both phase and intensity as a function of system operating parameters and solar-ionospheric disturbance level. Correction is made for multiple scatter, and the user may choose either one-way (communication) or two-way (radar) propagation.

1982-01-01

392

Computer model of high-latitude scintillation  

International Nuclear Information System (INIS)

The DNA Wideband satellite experiment provided extensive data on scintillation produced in high-altitude structured plasmas. A computer program, WBMOD, is being developed to summarize those data in an applications-oriented way. The program contains the phase-screen scattering theory of Rino and a morphological description of ionospheric irregularities (thus far only at auroral latitudes) based on Wideband observations. It permits a user to compute scintillation indices for both phase and intensity as a function of system operating parameters and solar-ionospheric disturbance level. Correction is made for multiple scatter, and the user may choose either one-way (communication) or two-way (radar) propagation.

393

Computer control of fuel handling activities at FFTF  

International Nuclear Information System (INIS)

The Fast Flux Test Facility near Richland, Washington, utilizes computer control for reactor refueling and other related core component handling and processing tasks. The computer controlled tasks described in this paper include core component transfers within the reactor vessel, core component transfers into and out of the reactor vessel, remote duct measurements of irradiated core components, remote duct cutting, and finally, transferring irradiated components out of the reactor containment building for off-site shipments or to long term storage. 3 refs., 16 figs.

1985-09-08

394

Computer Simulation of Factors Affecting Rural Education.  

Science.gov (United States)

Computer simulations of agricultural finance and management may be helpful to students preparing for agricultural careers. Simulations would provide problem definition and problem solving in realistic interactions with complex and ambiguous situations similar to those encountered in farming. The paper describes a major financial problem for farmers, explores the implications of that problem for students, and outlines a computer-based simulation model which would give students experience in dealing with the problem. Data sources for simulations, potentials of interactive exercises among students, and advantages of using real data with existing ambiguities are described. The board game "AGRICULTURE" is discussed as a prototype for simulation. (LFL)

1986-02-01

395

Computational Analysis of the SRS Phase III Salt Disposition Alternatives  

Energy Technology Data Exchange (ETDEWEB)

Completion of the Phase III evaluation and comparison of salt disposition alternatives was supported with enhanced computer models and analysis for each case on the ''short list'' of four options. SPEEDUP(TM) models and special purpose models describing mass and energy balances and flow rates were developed and used to predict performance and production characteristics for each of the options. Results from the computational analysis were a key part of the input used to select a primary and an alternate salt disposition alternative.

1999-10-07

396

Computation of Reducts Using Topology and Measure of Significance of Attributes  

CERN Document Server

Data generated in the fields of science, technology, business and in many other fields of research are increasing in an exponential rate. The way to extract knowledge from a huge set of data is a challenging task. This paper aims to propose a hybrid and viable method to deal with an information system in data mining, using topological techniques and the significance of the attributes measured using rough set theory, to compute the reduct, This will reduce the randomness in the process of elimination of redundant attributes, which, in turn, will reduce the complexity of the computation of reducts of an information system where a large amount of data have to be processed.

2010-01-01

397

CLEO: a knowledge-based refueling assistant at FFTF  

International Nuclear Information System (INIS)

A computer software system, CLEO, is used to assist in the planning and performance of the reactor refueling operations at the Fast Flux Test Facility (FFTF). It is a recently developed application of artificial intelligence software with both expert systems and automated reasoning aspects. CLEO, an acronym for Cloned LEO, is a logic-based computer program written in Pascal. It imitates the processes that the refueling expert for FFTF performs in organizing the refueling of FFTF. The computer assistant seeks to organize the sequence of core component movements according to the rules and logic used by the expert. In this form, CLEO has aspects that tie it to both the expert systems and automated reasoning areas within the artificial intelligence field.

1985-11-10

398

Year 2000 Computing Issues Related to the Defense Fuels ...  

Science.gov (United States)

... manual efforts by DESC and the Defense Finance and Accounting Service would ... in serious mission and financial impacts on DLA, DESC, the ...

1999-05-17

400

Use of Morphological Signal Processing and Computational - NASA  

Science.gov (United States)

Al-Balushi KR, Samanta B. Gear fault diagnosis using energy-based features of acoustic emission signals. Proc. IMechE, Part I: ...

401

United States Air Force Computer-Aided Acquisition and ...  

Science.gov (United States)

... of Packaging Requirements. MIL-STD-2073-1 DoD Packaging Data Forms Instruction for Preparation and Use. I DATA ...

1988-10-01

402

Unclas - NASA Technical Report Server (NTRS)  

Science.gov (United States)

COMPUTER PROGRAM GRADE. FOR DESIGN AND ANALYSIS. OF GRADED-POROSITY HEAT-PIPE. WICKS. Contract No. NAS 2-8310. August 1974. Prepared by. J. E. Eninger ...

403

ToxCast(tm) | Computational Toxicology Research Program (CompTox...  

Science.gov (United States)

from a broad range of sources including industrial and consumer products, food additives and drugs that never made it to the market to evaluate the predictive toxicity...

2011-06-15

404

Towards a Credibility Assessment ... - NASA Technical Reports Server  

Science.gov (United States)

10Oberkampf, W.L., Pilch, M., and Trucano, T.G., Predictive Capability Maturity Model for Computational Science and. Engineering, Sandia Report ...

405

The Shifty Nature of Grains  

Science.gov (United States)

... Astronomy & Space Biology Chemistry & Materials Computing Earth & Environment Education ... Materials Research Center at the University of Chicago, one of nearly 30 NSF-supported Materials ...

406

The Changing Face of Urology in 2005  

UK PubMed Central (United Kingdom)

The practice of urology is changing, not only from a medical and technological standpoint, but also from a business standpoint. New and improved computer technology and enhanced databases have allowed...Full Text Available

2004-01-01

407

The Challenges of Multidisciplinary Education in Computer Science  

British Library Electronic Table of Contents (United Kingdom)

Some of the most important problems facing the United States and China, indeed facing our entire planet, require approaches that are fundamentally multidisciplinary in nature. Many of those require skills in computer science (CS), basic understanding of another discipline, and the ability to apply the skills in one discipline to the problems of another. Modern training in computer science needs to prepare students to work in other disciplines or to work on multidisciplinary problems. What do we do to prepare them for a multidisciplinary world when there are already too many things we want to teach them about computer science? This paper describes successful examples of multidisciplinary education at the interface between CS and the biological sciences, as well as other examples involving C...

2011-01-01

408

Science and Technology Centers  

Science.gov (United States)

... MPS) Advanced Liquid Crystalline Optical Materials Superconductivity Computation and Visualization ... Cement-Based Materials Synthesis, Growth, and Analysis of Electronic Materials Photoinduced Charge ...

409

Sandia National Labs: PCNSC: Departments: Semiconductor Material...  

Science.gov (United States)

For coupled quantum wires and dots, tunneling effects and coherent transport for quantum computing are being studied. In 2D systems, electron-hole bilayers for exciton...

2011-07-05

410

PyMVPA: A Unifying Approach to the Analysis of Neuroscientific Data  

UK PubMed Central (United Kingdom)

The Python programming language is steadily increasing in popularity as the language of choice for scientific computing. The ability of this scripting environment to access a huge code base in various...Full Text Available

411

Prediction of Chemicals Ecotoxicity  

International Science & Technology Center (ISTC)

Computer-Aided Prediction of Chemical Ecotoxicity on the basis of Quantitative Structure-Activity Relationships with the Use of Physico-Chemical Descriptors, Including H-bond Parameters

412

Power Analyzer for Pocket Computing (PAPC)  

Science.gov (United States)

... Those functions are fundamental routines to build a power model for more complex circuits or functional blocks. ... 21 of 54 6. Memory Power Model ...

2004-01-01

413

Piccolo logic for a picture database computer and its implementation  

Energy Technology Data Exchange (ETDEWEB)

The logic named Piccolo for a picture database computer and its implementation is presented. The logic is shown to have three major advantages. One advantage is that the computer design based on this logic can handle a universal variety of pictorial data structures. Another advantage is that a set of data generated by rules such as texture distribution rules is stored in the picture computer efficiently. The third advantage is that this logic can serve as the basis of a logic for parallel processing machines. For implementation of the logic, a new methodology named architecture engineering is introduced as an architecture/design oriented methodology. Implementation case studies show the usefulness of the methodolgy. Two implementations on an abstract machine that are also on a parallel LISP machine are reported. 19 references.

1982-10-01

414

Parallelization of the FLAPW method  

International Nuclear Information System (INIS)

The FLAPW (full-potential linearized-augmented plane-wave) method is one of the most accurate first-principles methods for determining electronic and magnetic properties of crystals and surfaces. Until the present work, the FLAPW method has been limited to systems of less than about one hundred atoms due to a lack of an efficient parallel implementation to exploit the power and memory of parallel computers. In this work we present an efficient parallelization of the method by division among the processors of the plane-wave components for each state. The code is also optimized for RISC (reduced instruction set computer) architectures, such as those found on most parallel computers, making full use of BLAS (basic linear algebra subprograms) wherever possible. Scaling results are presented for systems of up to 686 silicon atoms and 343 palladium atoms per unit cell, running on up to 512 processors on a CRAY T3E parallel ...

1999-12-01

415

Optimal Bernoulli Routing in an Unreliable M/G/1 Retrial ...  

Science.gov (United States)

... system size exhibit a stochastic decomposition property ... to manage congestion in the primary queue. ... video at individual computer network terminals. ...

2011-05-15

416

NYA CR-54408 CONTRACT NAS 3-6264 - NASA Technical Reports Server  

Science.gov (United States)

It should be noted that computer -grade aluminum electrolytic capacitors. In order to limit the ripple in the source current to 270 (RMS) when the ...

417

NASA/DOD Aerospace Knowledge Diffusion Research Project. Paper 19: Computer and information technology and aerospace knowledge diffusion  

Science.gov (United States)

To remain a world leader in aerospace, the US must improve and maintain the professional competency

1992-01-01

418

NASA partners with teacher institute NASA strives to improve computers  

Science.gov (United States)

of the digital hearing aid technology that led to the cochlear implant. Former. Marshall Space Flight Center engineers. John Richardson and Joseph Howard ...

419

NASA - IT Summit 2011 Speaker Bios  

Science.gov (United States)

Aug 1, 2011 ... James holds a Bachelor of Science degree in Computer Science and certifications as CISSP, CCNA, and CCDA. show hide. Phillip A. Newman ...

420

Jeffrey W. McCandless: Computer Vision - NASA Vision Group  

Science.gov (United States)

Jeffrey W. McCandless is a post-doctoral researcher at NASA Ames Research Center in the Human Factors Research and Technology Division.

421

JPL.NASA.GOV: Scientists Study Desert Air to Understand Weather ...  

Science.gov (United States)

Aug 18, 2004 ... The Arabian Gulf region presents a challenge to meteorologists trying to simulate weather with computer models because sea-surface and land ...

422

Information Technology - NASA Science  

Science.gov (United States)

Mar 15, 2011 ... Information Technology. NCCS Discover Supercomputer. Science mission data collection, analysis and simulations pose unprecedented computer ...

423

HPCC and the National Information Infrastructure: an overview.  

UK PubMed Central (United Kingdom)

The National Information Infrastructure (NII) or "information superhighway" is a high-priority federal initiative to combine communications networks, computers, databases, and consumer electronics to...Full Text Available

1995-01-01

424

GENERALIZATION OF POSTURE TRAINING TO COMPUTER WORKSTATIONS IN AN APPLIED SETTING  

UK PubMed Central (United Kingdom)

Improving employees' posture may decrease the risk of musculoskeletal disorders. The current paper is a systematic replication and extension of Sigurdsson...Full Text Available

2011-01-01

425

From Frequency to Meaning: Vector Space Models of Semantics  

CERN Document Server

Computers understand very little of the meaning of human language. This profoundly limits our ability to give instructions to computers, the ability of computers to explain their actions to us, and the ability of computers to analyse and process text. Vector space models (VSMs) of semantics are beginning to address these limits. This paper surveys the use of VSMs for semantic processing of text. We organize the literature on VSMs according to the structure of the matrix in a VSM. There are currently three broad classes of VSMs, based on term-document, word-context, and pair-pattern matrices, yielding three classes of applications. We survey a broad range of applications in these three categories and we take a detailed look at a specific open source project in each category. Our goal in this survey is to show the breadth of applications of VSMs for semantics, to provide a new perspective on VSMs for ...

2010-01-01

426

Fractal parameters and vascular networks: facts & artifacts  

UK PubMed Central (United Kingdom)

BackgroundSeveral fractal and non-fractal parameters have been considered for the quantitative assessment of the vascular architecture, using a variety of test specimens and of computational...Full Text Available

427

Flow simulation of the Component Development Integration Facility magnetohydrodynamic power train system  

Energy Technology Data Exchange (ETDEWEB)

This report covers application of Argonne National Laboratory`s (ANL`s) computer codes to simulation and analysis of components of the magnetohydrodynamic (MHD) power train system at the Component Development and Integration Facility (CDIF). Major components of the system include a 50-MWt coal-fired, two-stage combustor and an MHD channel. The combustor, designed and built by TRW, includes a deswirl section between the first and the second-stage combustor and a converging nozzle following the second-stage combustor, which connects to the MHD channel. ANL used computer codes to simulate and analyze flow characteristics in various components of the MHD system. The first-stage swirl combustor was deemed a mature technology and, therefore, was not included in the computer simulation. Several versions of the ICOMFLO computer code were used for the deswirl section and second-stage combustor. The MGMHD code, ...

1997-11-01

428

FAQs for IIS Solicitation NSF-05551  

Science.gov (United States)

... Science, Computer Vision, Digital Government, Digital Libraries, Digital Society and Technologies ... for Robust Intelligence, Digital Government, and Digital Libraries and Archives. In subsequent years ...

429

Dr. Christos C ... - Research and Technology Directorate - NASA  

Science.gov (United States)

Jul 24, 2008... (9) coupled multi-disciplinary methods, (10) computational simulation of low cost component fabrication, (11) thermal electrical equivalence ...

430

Diagnostic Value of C-reactive Protein in Complicated Appendicitis  

UK PubMed Central (United Kingdom)

PurposeEarly detection of appendicitis has increased due to development of computed tomography and ultrasonography, yet we are frequently meeting complicated appendicitis, including...Full Text Available

2011-06-01

431

Department of Energy: MICS (Mathematical Information, and Computational Sciences Division). High performance computing and communications program  

Energy Technology Data Exchange (ETDEWEB)

This document is intended to serve two purposes. Its first purpose is that of a program status report of the considerable progress that the Department of Energy (DOE) has made since 1993, the time of the last such report (DOE/ER-0536, {open_quotes}The DOE Program in HPCC{close_quotes}), toward achieving the goals of the High Performance Computing and Communications (HPCC) Program. The second purpose is that of a summary report of the many research programs administered by the Mathematical, Information, and Computational Sciences (MICS) Division of the Office of Energy Research under the auspices of the HPCC Program and to provide, wherever relevant, easy access to pertinent information about MICS-Division activities via universal resource locators (URLs) on the World Wide Web (WWW). The information pointed to by the URL is updated frequently, and the interested reader is urged to access the WWW for the latest information.

1996-06-01

432

Cost Sensitivity Analysis for Radiology Department Planning  

UK PubMed Central (United Kingdom)

Two complementary computer programs have been developed for forecasting the demands and evaluating the costs of proposed radiographic facilities. The models are employed here in analyses of the sensitivity...Full Text Available

1971-01-01

433

Computer-Aided Acquisition and Logistic Support Gateway ...  

Science.gov (United States)

... Army, Navy, Air Force Procedures (JANAP) 128 AUTODIN Operating Procedures. ... JANAP = Joint Army, Navy, Air Force Procedures ...

1989-09-01

434

Computer vision syndrome: a review of ocular causes and potential treatments.  

Science.gov (United States)

Citation information: Rosenfield M. Computer vision syndrome: a review of ocular causes and potential treatments. Ophthalmic Physiol Opt 2011, 31, 502-515. doi: 10.1111/j.1475-1313.2011.00834.x ABSTRACT: Computer vision syndrome (CVS) is the combination of eye and vision problems associated with the use of computers. In modern western society the use of computers for both vocational and avocational activities is almost universal. However, CVS may have a significant impact not only on visual comfort but also occupational productivity since between 64% and 90% of computer users experience visual symptoms which may include eyestrain, headaches, ocular discomfort, dry eye, diplopia and blurred vision either at near or when looking into the distance after prolonged computer use. This paper reviews the principal ocular causes for this condition, namely oculomotor ...

2011-04-12

435

Computer Controlled MHD Power Consolidation and Pulse ...  

Science.gov (United States)

... is a standard in the utility industry which is used to study switching transients on power distribution networks and high-voltage transmission lines. ...

1990-08-01

436

Computational experience with an explicit difference scheme for a one phase Stefan problem  

Science.gov (United States)

The results of a computational scheme of Rose (a method for calculating solutions of parabolic equations with free boundary, Math. Comp., 14: 249-256(1960)) are compared with the known analytic solution of a single-phase Stefan problem with constant boundary temperature. Rose's scheme was implemented in FORTRAN on a DEC PDP-10. Computations were performed for Stefan numbers St = 0.01, 0.1, 1, 10, and 100. Three relative mesh sizes (..gamma.. = DT/(DX)/sup 2/ = 1/2, 1/6, and 1/25) were used. For each St, the relative mesh size had very little effect on accuracy. However, taking ..gamma.. = 1/25 resulted in dramatically increased computing time. The relative errors of temperature were large near the phase change front. 11 figures, 5 tables.

1980-07-01

437

Comments on "Routh Stability Criterion"  

CERN Document Server

In this note, we have shown special case on Routh stability criterion, which is not discussed, in previous literature. This idea can be useful in computer science applications.

2010-01-01

438

Center for Intelligent Information Retrieval  

Science.gov (United States)

evaluation, novelty detection, resource discovery, interfaces and visualization, digital libraries, computational social science, and cross-lingual information retrieval. The CIIR...

2011-08-31

439

Cancer gene discovery in mouse and man  

UK PubMed Central (United Kingdom)

AbstractThe elucidation of the human and mouse genome sequence and developments in high-throughput genome analysis, and in computational tools, have made it possible to profile entire...Full Text Available

2009-12-01

440

Can you count on computers?  

CERN Document Server

"Machines of all kinds depend on complex software to keep them operating safely. But how reliable is the software - and how can we be sure it is reliable?" (4 pages)

1989-01-01

441

CERN scientists confront data deluge  

CERN Multimedia

The next generation of particle accelerator is currently being designed at CERN. An understanding of the market forces in the computer industry will play a crucial role in the success of the project.

1998-01-01

442

CDDIS | What Was New 2000  

Science.gov (United States)

respectively. This is a NASA and GSFC requirement to help ensure our computer and network security on center. In the near future, ftp access, with the exception of anonymous ftp of...

2011-10-14

443

BIG BEAR SOLAR OBSERVATORY - NASA Technical Report Server (NTRS)  

Science.gov (United States)

replacing the KDP crystal, and introducing computer programs for accumulation of an almost unlimited number of frames. The calibration procedure using solar ...

444

Astrogram Issue 6/26/98 - NASA  

Science.gov (United States)

tables & chairs, Gaggenau Cooktop & Oven, 12' ladder,. TV stands, futons. B/O. Call (650) 948-4831. Computer System Performa upgraded to LCIII. ...

445

An Artificial Immune System-Inspired Multiobjective ...  

Science.gov (United States)

... BFS Breadth-First Search BIS Biological Immune System CCNA Cisco-Certified Network Associate CDIS Computer Defense Immune System ...

2007-03-01

446

An Algorithmic Solution for a Queueing Model of a Computer ...  

Science.gov (United States)

... time the terminal becomes active and begins the process of ... The model class considered here is of a single server queueing ... 1 I are both stochastic. ...

1981-01-01

447

Advances in Optimal Routing through Computer Networks  

Science.gov (United States)

... adaptive method called Shortest Queue plus Bias ... routing problem under stochastic traffic demands have ... of permits allocated to a node or terminal ...

1977-09-01

448

Ada Compiler Validation Summary Report: Certificate Number ...  

Science.gov (United States)

... Standards Validation Group National Computer Systems Laboratory National Institute of Standards and Technology ... STANDARD. ... (See test Ci )i3A. ...

1989-08-18

449

A numerical investigation of scale-up effects on coke yields of a thermal cracking Riser reactor  

Energy Technology Data Exchange (ETDEWEB)

A validated computational fluid dynamics (CFD) computer code, ICRKFLO, was used to investigate the scale-up effects on the coke yields of thermal cracking riser factors. Comparisons were made for calculated coke yields of pilot- and commercial-scales riser units. Computational results show that the riser aspect ratio, reaction temperature, particle residence time, and particle/oil ratio have major impacts on the coke yield. A computational experiment was conducted to determine optimal operating conditions for a conceptual design of a commercial-scale riser unit. This experiment showed that the performance loss in scale-up from pilot to commercial scale may be almost completely recovered through optimizing the operating conditions after scale-up using the CFD simulations as a guide.

1995-05-01

450

A feedforward architecture accounts for rapid categorization  

UK PubMed Central (United Kingdom)

Primates are remarkably good at recognizing objects. The level of performance of their visual system and its robustness to image degradations still surpasses the best computer vision systems despite...Full Text Available

2007-04-10

451

A computational approach to the electronic and optical properties of Ru(II) and Ir(III) polypyridyl complexes: Applications to DSC, OLED and NLO  

British Library Electronic Table of Contents (United Kingdom)

Ruthenium(II) and Iridium(III) polypyridyl complexes have been intensively investigated due to their use in energy conversion and light-emitting devices and materials for non-linear optics. Quantum mechanical computer simulations of molecules and materials have become increasingly popular in the scientific community. Along with experimental investigations, such computational analyses can provide complementary information on the electronic and optical properties of transition metal compounds of interest for optoelectronic applications. Here, we provide a unified review of recent work carried out on computational investigations of a large series of Ruthenium(II) and Iridium(III) polypyridyl complexes, discussing the relations between their electronic structure and optical properties and thei...

2011-01-01

452

A DNA recombinant database management system.  

UK PubMed Central (United Kingdom)

A set of computer programs is described which constitutes a clone database management system. Maintenance of the database and the stocks of material is designed to be under the control of one person...Full Text Available

1983-07-11

453

A Computer Program for Wing 'Stibsonic Aerodynamic Performance ...  

Science.gov (United States)

of Aspect Ratio 2 With NACA 0005-63 Thickness Distribution,. Cambered and Twisted for a Trapezoidal Span Load Distribution. NACA RM A50K27a,, ...

454

A Composite Architecture for Network Security at JPL  

Science.gov (United States)

We advance a tentative composite model for computer security at JPL, together with inter and intra networking with other NASA centers and overseas clients.

1998-01-01

455

Measurement of dose-area product in diagnostic radiology as a method of assessing the radiation exposure. (Results, experience, proposals for improvement, recommendations relating to radiological protection). Report of an expert meeting; Die Messung des Dosisflaechenproduktes in der diagnostischen Radiologie als Methode zur Ermittlung der Strahlenexposition. (Ergebnisse, Erfahrungen, Verbesserungsvorschlaege und Empfehlungen zum Strahlenschutz). Bericht ueber ein Expertentreffen  

Energy Technology Data Exchange (ETDEWEB)

The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product measurement in the dosimetry activities in medical ...

1995-12-31

456

Clinical implementation of a convolution based algorithm for 3D treatment planning  

International Nuclear Information System (INIS)

Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A computer ...

457

Waste monitoring system for effluents  

Energy Technology Data Exchange (ETDEWEB)

The waste monitoring system in use at Los Alamos National Laboratory`s Plutonium Facility, TA-55, is a computer-based system that proves real-time information on industrial effluents. Remote computers monitor discharge events and data moves from one system to another via a local area network. This report describes the history, system design, summary, instrumentation list, displays, trending screens, and layout of the waste monitoring system.

1995-07-01

458

Thyroidal uptake of iodine-123 in children using a gamma camera and computer  

Energy Technology Data Exchange (ETDEWEB)

The measurement of thyroidal uptake of radioiodine using a gamma camera and computer is described. In 12 children there was good agreement with simultaneous measurements using a probe, while in a further 14 patients the uptake values were consistent with the clinical diagnosis. The technique should be especially useful for infants and small children.

1985-10-01

459

The results of investigations in connection with development of methods for integrated optimization of fast reactors parameters  

International Nuclear Information System (INIS)

The results for development of methods and computer programs for integrated optimization of parameters of perspective fast reactors are given. The possibilities of the program for the reactor campaign calculation are analysed. This program is based on utilisation of the Bubnov-Galerkin method and Wigner disturbance theory. The possibility of application of approximation methods for the optimization researches is discussed. The results of development of the programs for complex reactor computations with account of control rods system and change of physical parameters in the reactor campaign are discussed. (author).

1974-07-01

460

The LLNL computer control system  

Energy Technology Data Exchange (ETDEWEB)

Lawrence Livermore National Laboratory (LLNL) has implemented a computer control system for operation of an FN tandem accelerator. The control software utilized is the Thaumaturgic Automated Control Logic (TACL) written by the Continuous Electron Beam Accelerator Facility and co-developed with LLNL. Details of the design philosophy, hardware configuration, control software, and special control algorithms will be presented. 2 refs., 4 figs.

1991-10-03

461

Technical and economic assessment of computer vision for industrial inspection and robotic assembly  

Energy Technology Data Exchange (ETDEWEB)

The use of computer vision to detect, measure, and perhaps guide the assembly of man-made components is potentially a very significant research and development area. The efficacy of these techniques for any given application depends on both technical and economic considerations. This paper will explore both these considerations using appropriate generic examples. It is our goal to first present a concise discussion of the present state of many technical and economic factors and then extrapolate these factors into the future for the purpose of guiding further investigations.

1981-12-01

462

Superspace evaluation of the two-loop effective potential for the O'Raifeartaigh model  

CERN Document Server

All-order spurion-corrected superpropagators and superfield Feynman rules are employed to systematically compute a two-loop corrected effective potential for the O'Raifeartaigh model, that realizes spontaneous supersymmetry breaking. Though the shifted superpropagators are rather nontrivial, superspace techniques may be suitably extended and confirm their efficacy in computing radiative corrections even when supersymmetry breakdown occurs.

2010-01-01

463

Significance of cranial computer tomography for the early diagnosis of peri- and postnatal damage  

Energy Technology Data Exchange (ETDEWEB)

It is reported on examination-technical possibilities with craniocerebral Computer Tomography in the peri- and postnatal period. Some typical tomographic images from a 17 1/2 months period in our own patient material of 327 children are demonstrated. The special advantages of this new technical-extensive method are: exact diagnoses, observation possibility of the longitudinal section, and the absolute harmlessness to the child.

1981-01-01

464

Satellite power systems (SPS) concept definition study (Exhibit D). Volume 4, Part 2: cost and programmatics appendix. Final report  

Energy Technology Data Exchange (ETDEWEB)

Cost and programmatic aspects of a recommended satellite power system are documented. Computer generated summaries are presented, and the detailed computer runs structured in a Work Breakdown Structure are given. The six configurations developed during the study period are summarized.

1981-03-01

465

Results for the structural properties of random heaps of hard disks  

Energy Technology Data Exchange (ETDEWEB)

The average angle of repose and the packing density of random planar heaps of hard disks falling ballistically onto a sticky base line, where the first layer of disks is quenched in random positions, are computed for heaps with a small fixed number of gaps in the base layer. The results we find appear to be almost independent of the size of the heap and they agree with those obtained from computer simulations of large systems.

1995-01-01

466

Residential accessibility to information technology retailers and self reported computer use among patients attending community clinics  

UK PubMed Central (United Kingdom)

The actual mechanisms that maintain the individual disparities in home computer use and internet access that are collectively termed “the digital divide” remain unclear. We hypothesized...Full Text Available

2009-01-01

467

Real time control of micro-machine system using micro-computer based fuzzy logic power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

A micro-computer based fuzzy logic power system stabilizer is applied to a micro-machine system to investigate its efficiency in real time control. The stabilizing signal is determined by using measured speed or real power signals at every sampling time to damp the system oscillations. The results show the proposed stabilizer improves the system damping effectively subject to various types of disturbances.

1994-12-01

468

Performance estimates for attached-sunspace passive solar heated buildings  

Energy Technology Data Exchange (ETDEWEB)

Performance predictions have been made for attached-sunspace types of passively solar heated buildings. The predictions are based on hour-by-hour computer simulations using computer models developed in the framework of PASOLE, the Los Alamos Scientific Laboratory (LASL) passive solar energy simulation program. The models have been validated by detailed comparison with actual hourly temperature measurements taken in attached-sunspace test rooms at LASL.

1980-01-01

469

Optical and statistical model calculation of the americium 242m capture cross section  

International Nuclear Information System (INIS)

The capture cross sections of Am 242m can be deduced from resonances analysis at low energy and computed with theoretical models at high energy. In this work, a coherent set of cross sections which reproduced the experimental values of the fission cross sections is computed. These calculations were performed for an energy of the incoming neutron between 1 keV and 1 MeV.

470

On-line replacement of a particle accelerator control computer  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the conversion from an existing production control computer, an SEL 840, to a DEC VAX 11/780. The plan is to add a layer of hardware to accomplish a smooth and gradual transition from the 840 to the VAX while leaving the underlying equipment unchanged. The architecture of the control system software is discussed for a large linear accelerator from the standpoint of its requirements and the particular design philosophy chosen.

1981-01-01

471

On the Stefan Problem with Volumetric Energy Generation  

Science.gov (United States)

This paper presents results of solid-liquid phase change, driven by volumetric energy generation, in a vertical cylinder. We show excellent agreement between a quasi-static, approximate analytical solution valid for Stefan numbers less than one, and a computational model solved using the CFD code FLUENT®. A computational study also shows the effect that the volumetric energy generation has on both the mushy zone thickness and convection in the melt during phase change.

2009-11-01

472

Metalloporphyrin catalysts for oxygen reduction developed using computer-aided molecular design  

Energy Technology Data Exchange (ETDEWEB)

The objective of this project is the development of a new class of metalloporphyrin materials used as catalsyts for use in fuel cell applications. The metalloporphyrins are excellent candidates for use as catalysts at both the anode and cathode. The catalysts reduce oxygen in 1 M potassium hydroxide, as well as in 2 M sulfuric acid. Covalent attachment to carbon supports is being investigated. The computer-aided molecular design is an iterative process, in which experimental results feed back into the design of future catalysts.

1996-04-01

473

Mathematical and physical model of steam-water mixture flow in horizontal steam generator  

International Nuclear Information System (INIS)

A mathematical and physical model was constructed describing the hydrodynamics of the two-phase mixture in the horizontal steam generator. The HP 9830 A desk-top calculator was used for the computations. The output variable of the solution was the level shape. A quantitative and qualitative comparison was made of the results of computations and experimental data. (author).

1982-10-01

474

Magnetic excitations in amorphous ferromagnets  

Science.gov (United States)

Neutron scattering techniques have been used to measure the static structure and magnetic excitations in amorphous magnets. Sum rules and computer models are used to discuss the relationship between the static disorder and the shape of the excitation spectrum. Polarized beam measurements of chi''(Q,E) are compared to analytical theories and computer calculations for the magnetic excitations in amorphous ferromagnets.

1978-03-01

475

MILSTAR/FEP (FLTSATCOM EHF package) emphemeris package  

Science.gov (United States)

Design constraints require that as Earth terminal attempting communications with a FLTSATCOM EHF Package (FEP) located onboard a FLTSATCOM satellite be provided with an accurate FEP package. To be precise, the terminal is provided with a coefficient element set from which the ephemeris of a satellite may be computed. This report describes the operation of a user friendly computer program that produces the above mentioned coefficient set so as to provide reference benchmarks from which the ephemeris related operations of the terminal can be judged.

1986-08-01

476

Levels of ICT use in teaching and administration  

DEFF Research Database (Denmark)

The computer facilities and the computer expertise at certain departments at Aalborg University made these departments natural starting points for integration of Information and Communication Technology (ICT) in their activities. This utilization and integration of ICT was not organized from the top or intermediate levels. It developed from the grassroots. Today Aalborg University as a whole can be said to be a truly ICT integrated institution. The quick development is to a high extent due to a structure with a finely distributed system of equipment, know-how and autonomy at all levels

2000-01-01

477

Incidental orbital calcifications on computed tomography scans; Calcificacoes orbitarias incidentais na tomografia computadorizada  

Energy Technology Data Exchange (ETDEWEB)

We retrospectively studied the computed tomography scans of the orbit in 75 patients in order to identify the presence of incidental calcifications (scleral and trochlear apparatus calcifications.). These imaging findings should integrate the vast list of differential diagnosis of orbital calcifications, as they may help radiologists to distinguish these calcifications from orbital foreign bodies. (author)

2001-02-01

478

Impact of computers in radiography: the advent of digital radiography, part-2  

International Nuclear Information System (INIS)

Computed radiography (CR) systems use a photostimulable phosphor plate enclosed in a cassette. In CR, image acquisition is a two-stage process wherein image capture and image read out are done separately. Direct digital radiography (DR) systems, on the other hand, use detectors that have a combined image capture and image read out capability. DR systems are also called as DDR or ddR systems by some vendors. This article focuses on DR systems

2008-08-01

479

Evaluation of peripheral vascular disease by intravenous digital subtraction angiography with the Fuji computed radiography (FCR) system  

Energy Technology Data Exchange (ETDEWEB)

Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management.

1987-03-01

480

Evaluation of peripheral vascular disease by intravenous digital subtraction angiography with the Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management. (orig.).

1987-01-01

481

Enabling Technologies for Petascale Electromagnetic Accelerator Simulation  

Energy Technology Data Exchange (ETDEWEB)

The SciDAC2 accelerator project at SLAC aims to simulate an entire three-cryomodule radio frequency (RF) unit of the International Linear Collider (ILC) main Linac. Petascale computing resources supported by advances in Applied Mathematics (AM) and Computer Science (CS) and INCITE Program are essential to enable such very large-scale electromagnetic accelerator simulations required by the ILC Global Design Effort. This poster presents the recent advances and achievements in the areas of CS/AM through collaborations.

2007-11-09

482

Employing Trusted Computing for the forward pricing of pseudonyms in reputation systems  

CERN Document Server

Reputation and recommendation systems are fundamental for the formation of community market places. Yet, they are easy targets for attacks which disturb a market's equilibrium and are often based on cheap pseudonyms used to submit ratings. We present a method to price ratings using trusted computing, based on pseudonymous tickets.

2006-01-01

483

Data compression using artificial neural networks  

Energy Technology Data Exchange (ETDEWEB)

This thesis investigates the application of artificial neural networks for the compression of image data. An algorithm is developed using the competitive learning paradigm which takes advantage of the parallel processing and classification capability of neural networks to produce an efficient implementation of vector quantization. Multi-Stage, tree searched, and classification vector quantization codebook design are adapted to the neural network design to reduce the computational cost and hardware requirements. The results show that the new algorithm provides a substantial reduction in computational costs and an improvement in performance.

1991-09-01

484

Computing quantum eigenvalues made easy  

Energy Technology Data Exchange (ETDEWEB)

An extremely simple and convenient method is presented for computing eigenvalues in quantum mechanics by representing position and momentum operators in matrix form. The simplicity and success of the method is illustrated by numerical results concerning eigenvalues of bound systems and resonances for Hermitian and non-Hermitian Hamiltonians as well as driven quantum systems. Various MATLAB program codes are listed. (author)

2002-07-01

485

Computer tomography of orbita in children  

Energy Technology Data Exchange (ETDEWEB)

The experiences are described of the examination of orbita in children using computer tomography (CT). Over a period of four years 42 examinations were performed of children in the age ranging between 7 months and 15 years, i.e., 2.7 percent of all CT examinations performed. The highest diagnostic yield was in orbita tumours. The possibilities of CT are demonstrated on examples.

1983-07-01

486

Computer simulation of martensitic transformations  

Energy Technology Data Exchange (ETDEWEB)

The characteristics of martensitic transformations in solids are largely determined by the elastic strain that develops as martensite particles grow and interact. To study the development of microstructure, a finite-element computer simulation model was constructed to mimic the transformation process. The transformation is athermal and simulated at each incremental step by transforming the cell which maximizes the decrease in the free energy. To determine the free energy change, the elastic energy developed during martensite growth is calculated from the theory of linear elasticity for elastically homogeneous media, and updated as the transformation proceeds.

1993-11-01

487

Computer modeling of two-phase flow  

Science.gov (United States)

The accelerating flow of a lighter continuous phase through a heavier one is considered. Small nonuniformities grow into large ones due to the Rayleigh-Taylor instability. An experiment exemplifying the large bubble formation due to Rayleigh-Taylor instability was performed and simulated using the PHOENICS 84 computer code. The same numerical procedure was applied to the two-phase flow in a gun barrel. It shows that the acceleration provided by the movement of the projectile can cause initial nonuniformities to grow with time.

1986-10-01

488

Computer modeling in the design and evaluation of electric and hybrid vehicles  

Energy Technology Data Exchange (ETDEWEB)

This demonstration project uses modern simulation techniques to illustrate the important technologies and design variables that an auto-designer would consider in production a high efficiency, low emissions vehicle. Simulation and modeling techniques use the idea of capturing the relationships between real components of the systems with mathematical equations. These equations are then solved on a computer to simulate the behavior or performance of the system under various conditions. In the current demonstration project, we focus on many variations of a hydrogen-powered vehicle.

1996-08-16

489

Computer Algebra meets Finite Elements: an Efficient Implementation for Maxwell's Equations  

CERN Document Server

We consider the numerical discretization of the time-domain Maxwell's equations with an energy-conserving discontinuous Galerkin finite element formulation. This particular formulation allows for higher order approximations of the electric and magnetic field. Special emphasis is placed on an efficient implementation which is achieved by taking advantage of recurrence properties and the tensor-product structure of the chosen shape functions. These recurrences have been derived symbolically with computer algebra methods reminiscent of the holonomic systems approach.

2011-01-01

490

Computed tomography - old ideas and new technology  

International Nuclear Information System (INIS)

Several recently introduced 'new' techniques in computed tomography - iterative reconstruction, gated cardiac CT, multiple-source, and dual-energy CT - actually date back to the early days of CT. We review the historic origins and evolution of these techniques, which may provide some insight into the latest innovations in commercial CT systems. (orig.)

2011-03-01

491

Calculation of the thermal load of a high voltage cable with forced circulation of oil with the help of modeling on an analog computer  

Energy Technology Data Exchange (ETDEWEB)

Equations are compiled for thermal balance in which for simplification, no consideration is made for heat conductivity along the axis of the cable and dependence of losses, heat capacitance and heat conductivity on temperature. Equations are modeled on a transistor analog calculator 42 TA. The solution to the task on the computer produced values of maximum temperature on the cable and coordinates of the point of maximum overheating. Using the analog model, one can study other parameters of the thermal mode.

1980-01-01

492

BUBL LINK: Natural language processing  

Wastenet

... Author: Radev, Dragomir R. Subjects: natural language processing DeweyClass: 764 Resource type: document Natural Language Processing Research Group Research Group based in the Department of Computer Science, University of Sheffield. Conducts research into natural language analysis topics including data mining/information extraction, dialogue, and semantics. Author: Department of Computer Science, University of Sheffield Subjects: natural language processing DeweyClass: 764 Resource ...

493

Automatic computation of three-loop two-point functions in large momentum expansion  

International Nuclear Information System (INIS)

We discuss the calculation of two-point three-loop functions with an arbitrary number of massive propagators and one large external momentum. The relevant subdiagrams are generated automatically. The resulting massless two-point integrals and massive tadpoles are transformed on-line to FORM-expressions ready to be used by existing FORM packages which calculate them analytically. As an example we compute the quartic mass corrections to the photon polarization function. (orig.).

494

Analysis of low-level computer vision algorithms for implementation on a very large scale integrated (VLSI) processor array  

Energy Technology Data Exchange (ETDEWEB)

In a recent paper, Lowry (1981) described an architecture for a computer vision rectangular processor array that is suitable for VLSI implementation. In this paper the authors review that architecture, discuss extensions to it and present results of an array simulator applied to vision algorithms. They also present an algorithm for re-routing an array with bad processors into a working subset of the array, making it feasible to implement a large array on one wafer-sized chip. 7 references.

1982-01-01

495

Analysis of Computer Experiments with Multiple Noise Sources  

DEFF Research Database (Denmark)

In this paper we present a modeling framework for analyzing computer models with two types of variations. The paper is based on a case study of an orthopedic surgical unit, which has both controllable and uncontrollable factors. Our results show that this structure of variation can be modeled effectively with linear mixed effects models and generalized additive models. Copyright (C) 2009 John Wiley & Sons, Ltd.

2010-01-01

496

An intercomparison of computer assisted date processing and display methods in radioisotope scintigraphy using mathematical tumours  

International Nuclear Information System (INIS)

Several computer assisted processing and display methods are evaluated using a series of 100 normal brain scintigrams, 50 of which have had single 'mathematical tumours' superimposed. Using a standard rating system, or in some cases quantitative estimation, LROC curves are generated for each method and compared. (author).

497

A novel CFD/structural analysis of a cross parachute  

Energy Technology Data Exchange (ETDEWEB)

A novel CFD/structural analysis was performed to predict functionality of a cross parachute under loadings near the structural limits of the parachute. The determination of parachute functionality was based on the computed structural integrity of the canopy and suspension lines. In addition to the standard aerodynamic pressure loading on the canopy, the structural analysis considered the reduction in fabric strength due to the computed aerodynamic heating. The intent was to illustrate the feasibility of such an analysis with the commercially available software PATRAN.

1993-12-31

498

A multi-micro-computer based dual-rate self-tuning power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

A dual-rate self-tuning control technique, in which the system identification and control calculation are performed separately, is proposed in this paper. This greatly increases the control rate. A self-tuning power system stabilizer (DSPSS) making use of this technique is developed and implemented using multi-micro-computers. Simulation and experimental results with DSPSS show that the increase in the control rate can considerably improve the system performance.

1987-09-01

499

A computer program for estimating decommissioning costs for light water reactors  

Energy Technology Data Exchange (ETDEWEB)

This report discusses a desk-top computer program has been developed for estimating the costs, waste volumes, and occupational radiation exposures associated with decommissioning light-water reactor power stations. Cost categories and cost algorithms used in the program are discussed and a brief description of the user interface is given.

1993-02-01