An equation of state of neutron star matter with strange baryons has been obtained. The effects of the strength of hyperon-hyperon interactions on the equations of state constructed for the chosen parameter sets have been analysed. Numerous neutron star models show that the appearance of hyperons is connected with the increasing density in neutron star interiors. The performed calculations have indicated that a change of the hyperon-hyperon coupling constants affects the chemical composition of a neutron star. The obtained numerical hyperon star models exclude a large population of strange baryons in the star interior.
Defect cluster formation in 14-MeV neutron irradiated polycrystalline copper has been observed by transmission electron microscopy (TEM) and correlated with the increase in yield stress. The measurements indicate that the radiation hardening component of the yield strength in polycrystals is not directly additive to the unirradiated yield strength. A transitional behavior was observed for radiation hardening at low fluences, which produces an anomalous variation of the defect cluster barrier strength with fluence. The behavior is attributed to the effect of grain boundaries on slip band transmission. An upper limit for the room temperature barrier strength of defect clusters in neutron-irradiated copper was determined to be #alpha#=0.23. (orig.).
The neutron capture cross sections of the stable molybdenum isotopes have been measured with high energy resolution (#DELTA#E/E < approximately 0.2%), between 3 and 90 keV neutron energy, at the 40 m station of ORELA. Average resonance parameters are extracted for s- and p-wave resonances. The s-wave neutronstrength function is close to 0.5x10"-"4 for all isotopes, but the p-wave strength function exhibits a well defined peak near A approximately 95. Both s- and p-wave radiative widths decrease markedly as further neutrons are added to the closed shell. The p-wave radiative widths are generally greater than the s-wave widths showing the presence of non-statistical #gamma#-decay mechanisms. Valence neutron theory fails to explain the magnitude of the p- to s-wave radiative width disparity and doorway state processes are invoked. In ...
A method of calculating the neutron source strength in irradiated Fast Flux Test Facility (FFTF), fuel has been developed and is presented in this paper. This method has been used to perform calculations in support of the reactivity monitoring of the FFTF reactor by the modified source multiplication method during refueling operations. 31 refs.
The properties of strange neutron stars have been studied with the use of the parameter sets stemming from the effective field theory. The impact of the strength of hyperon interactions on neutron star masses has been analyzed. The inclusion of additional nonlinear meson interaction terms together with the strong hyperon-hyperon interaction leads to the existence of additional stable stellar configurations. (authors)
Some results on mechanical property study of copper and titanium subjected to impact load and next to neutron irradiation are presented. It was shown that shock wave influence involves a substantial shape change of the stress-strain diagram and of respective mechanical characteristics. Yield- and ultimate strength were substantially increased, as well as hardness with a considerable drop of plasticity. Also a heat stability of copper and titanium specimens was studied after being treated with shock-waves and neutron radiation. Results are given of electron microscope study of titanium structure sfter explosion hardening, which caused decomposition of hydride segregations in titanium and increased dislocation density.
A time-reversal-violating spin-correlation coefficient in the total cross section for polarized neutrons incident on a tensor rank-2 polarized target is calculated by assuming a time-reversal-noninvariant, parity-conserving ``five-fold" interaction in the neutron-nucleus optical potential. Results are presented for the system $n + {^{165}{\\rm Ho}}$ for neutron incident energies covering the range 1--20 MeV. From existing experimental bounds, a strength of $2 \\pm 10$ keV is deduced for the real and imaginary parts of the five-fold term, which implies an upper bound of order $10^{-4}$ on the relative $T$-odd strength when compared to the central real optical potential.
The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system ...
The primary E1, M1 and E2 ..gamma..-radiation in /sup 87,88,89/Sr observed after thermal neutron capture was compared with the predictions of single particle and giant resonance models. The nuclei feature a wide range of neutron binding energies between 6.3 and 11.1 MeV, which makes a 5.5 MeV spectrum of primary transition energies available for investigation. The (n, ..gamma..) reaction was used to estimate the parameters of the spin-flip M1 giant resonance in strontium. The total energy weighted M1 strength of this resonance exceeds the results of shell model and random phase approximation calculations for /sup 90/Zr by a factor of 3-4. The E1 strengths were found to agree with the established giant dipole resonance model. The few data on primary E2 transitions do not allow to differentiate between the giant quadrupole resonance and the single particle models.
The primary E1, M1 and E2 #gamma#-radiation in "8"7","8"8","8"9Sr observed after thermal neutron capture was compared with the predictions of single particle and giant resonance models. The nuclei feature a wide range of neutron binding energies between 6.3 and 11.1 MeV, which makes a 5.5 MeV spectrum of primary transition energies available for investigation. The (n, #gamma#) reaction was used to estimate the parameters of the spin-flip M1 giant resonance in strontium. The total energy weighted M1 strength of this resonance exceeds the results of shell model and random phase approximation calculations for "9"0Zr by a factor of 3-4. The E1 strengths were found to agree with the established giant dipole resonance model. The few data on primary E2 transitions do not allow to differentiate between the giant quadrupole resonance and the single particle models. (orig.).
Radiation hardening and radiation-induced chromium (Cr) depletion were related to intergranular stress corrosion cracking (IGSCC) response among various stainless steels (SS). Available data on neutron-irradiated materials were analyzed and correlations developed between fluence, yield strength, grain-boundary Cr concentration, and cracking susceptibility in high-temperature water environments. Large heat-to-heat differences in the critical fluence (0.2 neutrons/cm"2 to 2.5 x 10"2"1 neutrons/cm"2) for IGSCC were documented. Variability often was consistent with yield strength differences among irradiated materials. IGSCC correlated better to yield strength than to fluence for most heats, suggesting a possible role for radiation-induced hardening (and microstructure) on cracking. However, isolated heats revealed a wide range of yield ...
The gadolinium isotopes are interesting for reactor applications as well as for medicine and astrophysics. The gadolinium isotopes have some of the largest neutron capture cross sections. As a consequence they are used in the control rod in reactor fuel assembly. From the basic science point of view, there are seven stable isotopes of gadolinium with varying degrees of deformation. Therefore they provide a good testing ground for the study of deformation dependent structure such as the scissors mode. Decay gamma rays following neutron capture on Gd isotopes are detected by the DANCE array, which is located at flight path 14 at the Lujan Neutron Scattering Center at Los Alamos National Laboratory. The high segmentation and close packing of the detector array enable gamma-ray multiplicity measurements. The calorimetric properties of the DANCE array coupled with the neutron time-of-flight technique enables ...
Neutron cross sections for Pu-239 and Am-241, -242m, -243 have been analyzed with the aid of theoretical models. A deformed optical potential that fits total, elastic and inelastic differential cross section data and neutronstrength functions for Pu-239 and Am-241 have been used. In case of Pu-239 the consistency of absolute fission data and (n, 2n) cross section is investigated. Because of the strong discrepancies in Am fission cross section data a consistent set of calculated cross section values for the chain of Am nuclei is proposed. The present state of knowledge concerning first chance fission cross section allows to analyze fission cross section data of Am-241, -242m, -243, up to 20 MeV. The results thus obtained are compared with ENDF/B-V and JENDL-3 libraries. (orig.).
The results of photoneutron spectra measurements for the reaction (#gamma#,n) on the Sr-88 nuclei near threshold are presented. The parameters of resonance levels, as well as radiative S_#gamma#"("1") and neutron S_n"("1") strength functions for transitions on the first excited level of Sr-87 were obtained. 2 refs.; 1 fig.; 1 tab.
A boron containing cement, which can be used as nuclear shielding material, is produced at pilot plant scale applying two different methods. In the first method, the raw mixture of a normal portland cement is mixed with pre-calcined colemanite, a calcium borate mineral, and clinkerized in a rotary kiln (borated-clinker). In the second method, the colemanite is mixed with an admixture, which contains mainly limestone and marl, and burnt in the rotary kiln to obtain a borated-lime composite. The borated-lime composite is then added to the normal portland cement clinker up to 2% B_2O_3 content for shielding purpose. The results have shown that the borated-clinker contained untolerable amount of free lime resulting in a decrease in compressive strength. The addition of the borated-lime composite to the normal portland cement clinker up to 1% B_2O_3 content did not alter the setting time and the volume expansion properties. The reduction in the compressive ...
Over the recent years the nuclear structure around the N = 50 shell closure, which is very pronounced in the strontium and zirconium isotopes, has been the subject of extensive experimental and theoretical work. On the proton side Z = 38 and Z = 40 provide fairly closed sub-shells. In the strontium isotopes the lg/sub 9/2/ neutron shell is closed at /sup 88/Sr, supplying relatively pure neutron-hole and neutron-particle states with large spectroscopic factors in /sup 87/Sr and /sup 89/Sr, as well as core-coupled states. The mass region is thus ideally suited to examine the transition from a correlated to an uncorrelated (chaotic.) excitational behavior. These two types are characterized e.g. by the density of excited states, the transition strengths, and the spectroscopic factors observed in transfer reactions. We conducted (n,..gamma..) and (d,p) reactions leading to /sup 87,88,89/Sr in addition to ...
Over the recent years the nuclear structure around the N = 50 shell closure, which is very pronounced in the strontium and zirconium isotopes, has been the subject of extensive experimental and theoretical work. On the proton side Z = 38 and Z = 40 provide fairly closed sub-shells. In the strontium isotopes the lg/sub 9/2/ neutron shell is closed at "8"8Sr, supplying relatively pure neutron-hole and neutron-particle states with large spectroscopic factors in "8"7Sr and "8"9Sr, as well as core-coupled states. The mass region is thus ideally suited to examine the transition from a correlated to an uncorrelated (chaotic?) excitational behavior. These two types are characterized e.g. by the density of excited states, the transition strengths, and the spectroscopic factors observed in transfer reactions. We conducted (n,#gamma#) and (d,p) reactions leading to /sup 87,88,89/Sr in addition to "8"8Sr(d,t)"8"7Sr ...
There is an urgent need to improve the reliability of screening cargo containers for illicit nuclear material that may be hidden there for terrorist purposes. A screening system is described for detection of fissionable material hidden in maritime cargo containers. The system makes use of a low intensity neutron beam for producing fission; and the detection of the abundant high-energy #gamma# rays emitted in the #beta#-decay of short-lived fission products and #beta#-delayed neutrons. The abundance of the delayed #gamma# rays is almost an order of magnitude larger than that of the delayed neutrons normally used to detect fission and they are emitted on about the same time scale as the delayed neutrons, i.e., #approx#1 min. The energy and temporal distributions of the delayed #gamma# rays provide a unique signature of fission. Because of their high energy, these delayed #gamma# rays penetrate loW--Z ...
Experimental measurements were made of the production cross sections and energy distributions of gamma rays emitted when the stable targets /sup 88/Sr, /sup 89/Y and /sup 90/Zr are exposed to protons in the energy range 3 to 8 MeV. The data are being analyzed using a recent version of the Uhl statistical model code. One conclusion is that while the gamma-ray strength functions employed reproduce the proton capture cross sections, they do not achieve the same degree of hardness observed in the measured spectra. To do so, their lower energy regions must be modified; such changes, however, do not affect the capture cross sections. 7 references.
High-resolution neutron capture cross section measurements of 55Mn were recently performed at GELINA by Schillebeeckx et al. (2005) and at ORELA by Guber et al. (2007). The analysis of the experimental data was performed with the computer code SAMMY using the Bayesian approach in the resonance parameters representation of the cross sections. The neutron transmission data taken in 1988 by Harvey et al. (2007) and not analyzed before were added to the SAMMY experimental data base. More than 95% of the s-wave resonances and more than 85% of the p-wave resonances were identified in the energy range up to 125 keV, leading to the neutronstrength functions S0 = (3.90 0.78) x 10-4 and S1 = (0.45 0.08) x 10-4. About 25% of the d-wave resonances were identified with a possible strength function of S2 = 1.0 x 10-4. The capture cross section calculated at 0.0253 eV is 13.27 b, and the capture ...
The available data on isolated X-ray pulsars, their wind nebulae, and the supernova remnants which are connected to some of these sources are analyzed. It is shown that electric fields of neutron stars tear off charged particles from the surface of neutron star and trigger the acceleration of particles. The charged particles are accelerated mainly in the field of magneto-dipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magneto-dipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.
The available data of single X-ray pulsars, their wind nebulae, and the SNRs which are connected to some of these sources are analysed. It is shown that electric field intensity of neutron stars tears off charged particles from the surface of neutron star and triggers the acceleration of particles. The charged particles are accelerated mainly in the field of magnetodipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magnetodipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.
The sequential layer-by-layer adsorption of polyanions and polycations to build polyelectrolyte multilayers has triggered enormous interest in their potential uses in a wide range of fields, from photonic to pharmaceutical applications. We show that the conformation of the solvent swollen films - prior to drying - is determined by the initial adsorption conditions, but can be altered ex-situ by exposure to a liquid phase of very high ionic strength. Recently it has been observed that the swelling depends on the charge of the outermost layer. In the PAH/PSS system we saw that assemblies with PSS as the outermost layer swell more than those with PAH outside. A neutron reflectivity study of this effect in addition indicated the existence of two kinds of water, bound with different strength within the films. Beside an unexpected two-step kinetics of swelling, the reflectivity curves of the layers against vacuum before and after ...
A study was made into microstructure and hardening in austenitic stainless steel 0Kh18N10T irradiated with neon ions (230 MeV) and neutrons (E_n > 0.1 MeV). The experiments were accomplished using an external beam of U-400 cyclotron (Dubna) and EWA reactor (Poland). The dependences of tensile properties, hardening index, microstructure, dislocation density on damaging dose were determined. An attempt is made to reveal the correlation between an yield strength increment and defect cluster accumulation. The interpretation of variations of mechanical properties and microstructure under irradiation is given.
We have investigated the effect of the rho tensor coupling on binding energies, matter root-mean-square radii and spin orbit splittings of Ca isotopes in the relativistic mean-field theory with sigma, omega, and rho mesons. It is shown that binding energies and matter root-mean-square radii are insensitive to an alteration in the strength of the rho tensor coupling and an explanation of this is given. We have further shown that inclusion of the rho tensor coupling will give isospin-dependent spin-orbit splittings and this will greatly affect spin-orbit splittings of nuclei near the neutron drip line. (author). Letter-to-the-editor.
The differential cross section measurements for /sup 241/Am, /sup 242m/Am and /sup 243/Am are reviewed in the energy range from 0.5 eV to 10 keV. Parameters extracted from resonance analysis, such as the neutronstrength function, the average level spacing, the average capture and fission widths, are compared for the various measurements. The average capture and fission cross sections from 100 eV to 10 keV are directly compared. The status of the data set is discussed with suggestions for further measurements. 24 references.
To investigate the influence of equal channel angular pressing on the microstructure and texture of the magnesium alloy AZ31, electron backscattering diffraction and well as neutron diffraction experiments were carried out. Through these experiments it was possible to trace the microstructure and texture evolution with strain accumulated with the increasing number of equal channel angular pressing passes. It was further demonstrated by subsequent compression tests that the microstructural changes produced by equal channel angular pressing have a beneficial effect on both the compressive strength and ductility of AZ31. (orig.)
Neutron-hole states in /sup 87/Sr were studied by means of the /sup 88/Sr("3He,#alpha#)/sup 87/Sr reaction at 36 MeV. Angular distribution measurements were carried out from 3"0 to 41"0 (lab) and analyzed with the zero-range distorted-wave Born approximation method. Spectroscopic factors have been determined for about 50 discrete levels in /sup 87/Sr located below 6 MeV excitation energy and for the three lowest isobaric analog states 2p(3/2, 1f(5/2, and 2p(1/2 observed around 11 MeV. Many l = 1 and l = 3 discrete levels are observed in the 3--6 MeV excitation energy range. In addition, a large part of the 1f-2p strength is found to lie in the higher-lying continuum up to 13 MeV (about 10% and 40% for the l = 1 and 3 contributions, respectively). The distribution of the 1f-2p neutron-hole strength is compared to previous data on neighboring nuclei /sup 89/Zr and /sup 91/Mo. In addition, angular ...
The world fusion program has advanced to the stage where it is appropriate to construct a number of devices for the purpose of burning DT fuel. In these next-generation experiments, the expected flux and fluence of 14 MeV neutrons and associated gamma rays will pose a significant challenge to the operation and diagnostics of the fusion device. Radiation effects include structural damage to materials such as vacuum windows and seals, modifications to electrical properties such as electrical conductivity and dielectric strength and impaired optical properties such as reduced transparency and luminescence of windows and fiber optics during irradiation. In preparation for construction and operation of these new facilities, the fusion diagnostics community needs to work with materials scientists to develop a better understanding of radiation effects, and to undertake a testing program aimed at developing workable solutions for this multi-faceted ...
Using a Q3D magnetic spectrometer the elastic and inelastic scattering of /sup 12/C on /sup 88/Sr and the neutron pick-up (/sup 12/C, /sup 13/C) has been studied. The spin alignment of the inelastically excited 2/sup +/ state of /sup 12/C (4.43 MeV) has been deduced from the line shapes broadened by the ..gamma..-decay in flight. Thus for each m-substate a full angular distribution was obtained. The m = 1 substate shows a shifted interference minimum, which is explained by the different strength of the Coulomb and nuclear amplitudes in the m-substates. The analysis of the data on elastic scattering, inelastic scattering, alignment and the neutron transfer can be described consistently with one choice of the optical model parameters.
A personal computer based single specimen unloading technique has been demonstrated using a nuclear grade pressure vessel material, A533B Class I steel, and an #alpha#-#beta# titanium alloy, CORONA-5. Experimental parameters investigated in the case of steel include the effect of test temperature, loading rate and neutron irradiation. Results revealed the effect of dynamic strain aging (DSA) as a drop in the critical crack initiation fracture toughness (Jsub(q)); the minimum in Jsub(q) shifts to higher temperatures at higher test speeds as predicted from DSA models. In CORONA-5, the effects of microstructure and heat treatment for two different sizes of equiaxed #alpha# morphology in a #beta#-matrix heat treated to different yield strengths were investigated. It is found that the observed higher values of Jsub(q) and tearing modulus result from a greater tortuosity of the crack path and ease of crack blunting. The largest increase in Jsub(q) ...
All the recent DEMO design studies for helium cooled divertors utilize tungsten materials and alloys, mainly due to their high temperature strength, good thermal conductivity, low erosion, and comparably low activation under neutron irradiation. The long-term objective of the EFDA fusion materials programme is to develop structural as well as armor materials in combination with the necessary production and fabrication technologies for future divertor concepts. The programmatic roadmap is structured into four engineering research lines which comprise fabrication process development, structural material development, armor material optimization, and irradiation performance testing, which are complemented by a fundamental research programme on "Materials Science and Modeling". This paper prese...
In [W. Ye, F. Wu, H.W. Yang, Phys. Lett. B 647 (2007) 118] prescission protons and ? particles of high-isospin 206Pb were shown to be almost independent of the dissipation strength Formula Not Shown . Subsequently, in [P.N. Nadtochy, et al., Phys. Lett. B 685 (2010) 258] prescission light charged particles (LCPs) were shown to have approximately the same sensitivity as neutrons to Formula Not Shown for 206Pb and 204Hg nuclei. In this Letter we point out that the reason for the apparent contradictory conclusions is that the authors in the latter did not compute the changes in the absolute yields of prescission LCPs multiplicities with increasing Formula Not Shown and compare them with typical experimental uncertainties. It is shown that the expected changes are very small in the case of ne...
The #gamma#-ray spectrum emitted after thermal neutron capture in "8"7Sr was studied at the ILL high flux reactor with pair- and intrinsic Ge-spectrometers. 661 transitions were assigned to the reaction "8"7Sr(n,#gamma#)"8"8Sr and 205 of them were placed into a "8"8Sr level scheme of 47 levels. This represents 88% of the observed intensity. The level energies were determined with a precision of better than 22 ppm; the neutron binding energy was determined as 11 112.69 (22) keV. To aid the analysis high resolution particle spectra of the reaction "8"7Sr(d,p)"8"8Sr were measured at 20 MeV deuteron energy with the Munich Q3D spectrometer. 85 states were observed with this reaction. The data helped to establish newly found levels and to differentiate between primary and secondary transitions in the (n,#gamma#) data. The observed level densities and primary transition strengths are compared with statistical model predictions and ...
Neutron diffraction was used to monitor elastic strains during in situ tension testing of a directionally solidified (DS) superalloy at 900 deg. C. Changes in misfit and thermal expansion coefficients of individual phases were obtained. In the {gamma} phase, it is demonstrated that elastic strains saturate at 350 MPa, which is well below the yield strength of the alloy. This is interpreted as the onset of dislocation glide through less stressed vertical channels. The critical resolved shear stress (CRSS) of {gamma} is found to be 143 {+-} 11 MPa, in agreement with a calculated CRSS that is dominated by Orowan bowing of dislocations through nanoscale-wide {gamma} channels. This provides confirmation of Orowan bowing in plasticity/creep of the {gamma} phase. Implications of CRSS and misfit in a 'threshold stress' for creep and rafting are discussed. The CRSS of {gamma}' is found to be consistent with pairwise ...
Polymer sealing parts are widely used in various branches of engineering as detachable joints that operate at normal and cryogenic temperatures. They are also used in nuclear-power engineering to seal pumps, pipelines, etc., where they operate at 600-650 K under a neutron fluence of around 10"1"6 cm"-"2 (E #>=# 0.18 MeV) and concomitant #gamma#-irradiation of about 10"6 R. The fluoroplastic-based materials currently used degrade when irradiated in water at 320-360 K with a neutron fluence of 10"1"5 cm"-"2 (thermal neutrons) or 10"1"4 cm"-"2 (fast neutrons), and a concomitant #gamma#-irradiation dose of 2 x 10"6 R. The strength of these fluoroplastics decreases markedly after #gamma#-irradiation (from a cobalt source) at room temperature at doses above 10"6 R. For this reason, flexible and swelling graphites are finding ever increasing application. Graflex foils made of extra-pure ...
Radiation hardening in austenitic stainless steels is shown to modify deformation characteristics and correlate well with an increased susceptibility to intergranular stress corrosion cracking (IGSCC). Available data on neutron-irradiated materials have been analyzed and correlations developed between fluence, yield strength and cracking susceptibility in high-temperature water environments. Large heat-to-heat differences in the critical fluence (0.2 to 2.5 x10"2"1 n/cm"2) for IGSCC are documented. In many cases, this variability is consistent with yield strength differences among irradiated materials. IGSCC correlates better to yield strength than to fluence for most heats suggesting a possible role of radiation-induced hardening and microstructure on cracking. Microstructural evolution during proton and heavy-ion irradiation has been characterized in low-carbon 304SSs. Hardening results from a ...
Ultimate compressive strength in the longitudinal direction. (3. Ultimate tensile strength in the transverse direction. U'. Ultimate compressive strength in ...
This paper presents an overview of research conducted with the support of the Australian Institute of Nuclear Science and Engineering, at the University of Melbourne, School of Earth Sciences, Radiochemical Neutron Activation Laboratory. The primary objective of this research is to realize the high potential of the platinum group elements (PGE) and gold to the solution of petrogenetic problems, the study of magma generation and magmatic processes in mafic/ultramafic rock suites, as tracers in hydrothermal ore formation. The PGEs (Os, Ru, Ir, Pt, Pd and Rh) are among the least abundant of all elements on earth with unique properties such as high melting points, high electrical and thermal conductivity, high density, strength and toughness as alloys. They exhibit both siderophile and chalcophile characteristics and are valuable tools in providing information about magmatic processes, in particular S-saturation, as well as crystal fractionation ...
The /sup 40/Ca(p,n)/sup 40/Sc reaction was studied at 134 MeV. Neutron energy spectra were measured by the time-of-flight technique with resolutions of 220 keV at angles from 0"0 to 41"0 and 415 keV out to 62"0. The 2"-,3"-,4"-,5"- band of states based on the (f/sub 7/2/,d/sub 3/2//sup -1/) 1p1h structure was observed at low excitation energies, in good agreement with known analog states in /sup 40/Ca and /sup 40/K. The shapes of the cross-section and analyzing-power angular distributions are in good agreement with distorted-wave impulse-approximation calculations using simple 1p1h (Tamm-Dancoff approximation) shell-model wave functions. A relatively strong transition to a state at E/sub x/ = 2.3 MeV with L = 3 is identified tentatively as a 4"- state with the predominant 1p1h structure (1f/sub 7/2/,2s/sub 1/2//sup -1/).
Nuclei in the mass-180 region have many high-{Omega} single-particle levels close to the Fermi energy and are, therefore, prime candidates for high-K isomers. Since both neutron and proton level densities are rather low, one should expect blocking and particle-number fluctuations to be rather important. We have performed good-particle-number calculations and have shown that the simpler blocked BCS theory gives a good approximation to the multi-quasiparticle spectra if the pairing strength is chosen appropriately. This has allowed us to perform a systematic theoretical study of this mass region. Residual spin-spin interactions are shown to be essential in reproducing the energies and even the correct order of known states. Good agreement has been found for {sup 175}Hf, {sup 176}Hf and {sup 177}Ta, where extensive data already exist. Predictions for new high-K states near the yrast line are made for these nuclei and for {sup 178}W. (orig.).
Nuclei in the mass-180 region have many high-#OMEGA# single-particle levels close to the Fermi energy and are, therefore, prime candidates for high-K isomers. Since both neutron and proton level densities are rather low, one should expect blocking and particle-number fluctuations to be rather important. We have performed good-particle-number calculations and have shown that the simpler blocked BCS theory gives a good approximation to the multi-quasiparticle spectra if the pairing strength is chosen appropriately. This has allowed us to perform a systematic theoretical study of this mass region. Residual spin-spin interactions are shown to be essential in reproducing the energies and even the correct order of known states. Good agreement has been found for "1"7"5Hf, "1"7"6Hf and "1"7"7Ta, where extensive data already exist. Predictions for new high-K states near the yrast line are made for these nuclei and for "1"7"8W. (orig.).
Irradiation of ferritic steels with neutrons in the temperture range of room temperature to #propor to# 450deg C results in lattice hardening, which causes an increase in strength and a decrease in ductility. Eight reduced-activation Cr-W-V stels with chromium concentration varying from 2.25 to 12% were irradiated at 365deg C to #propor to# 7 dpa in the Fast Flux Test Facility. A steel with 2.25% Cr and the combination of 2% W and 0.25% V hardened less than those containing vanadium or tungsten alone or a steel with 1% W and 0.25% V. The amount of hardening was similar for Cr-W-V steels with constant vanadium and tungsten concentrations and containing 2.,25, 5, and 9% Cr; a steel with 12% Cr hardened considerably more. Specimens of two conventional Cr-Mo steels, 9Cr-1MoVNb and 12Cr-1MoVW, were also irradiated, and the hardening of these steels was similar to analogous reduced-activation steels. (orig.).
We present first-time measurements of the Fermi surface and low-energy electronic structure of intermetallic compounds Gd_2PdSi_3 and Tb_2PdSi_3 by means of angle-resolved photoelectron spectroscopy (ARPES). We show that the Fermi surface in both compounds consists of an electron barrel at the #GAMMA# point surrounded by spindle-shaped electron pockets originating from the same band, with the band bottom of both features lying at 0.5 eV below the Fermi level. From the experimentally measured band structure, we estimate the momentum-dependent RKKY coupling strength and demonstrate that it is peaked at the 1/2#GAMMA# K wave vector. Comparison with neutron diffraction data from the same crystals shows perfect agreement of this vector with the propagation vector of the low-temperature in-plane magnetic order, thereby demonstrating the decisive role of the Fermi surface geometry in explaining the complex magnetically ordered ground state of ternary ...
Burnable poisons are used in nuclear reactors to produce a more level distribution of power in the reactor core and to reduce to necessity for a large control system. An ideal burnable poison would burn at the same rate as the fuel. In this study, separation of neutron-absorbing isotopes was investigated in order to eliminate isotopes that remain as absorbers at the end of fuel life, thus reducing useful fuel life. The isotopes Gd-157, Dy-164, and Er-167 were found to have desirable properties. These isotopes were separated from naturally occurring elements by means of plasma separation to evaluate feasibility and cost. It was found that pure Gd-157 could save approximately $6 million at the end of four years. However, the cost of separation, using the existing facility, made separation cost- ineffective. Using a magnet with three times the field strength is expected to reduce the cost by a factor of ten, making isotopically separated burnable ...
The major part of the chapter 'Physical Properties' in concerned with, in addition to nuclear and atomic properties, the properties of the metal molybdenum. Due to the huge number of relevant papers, the present volume comprises only the first part of the metal properties, i.e. the crystallographic properties, the electronic structure, the lattice dynamics, and subsequently the mechanical and thermal properties. There are two small sections where the properties of the molecules, primarily Mo/sub 2/ and Mo/sub 6/, and of the vapor are described. The strength and some other mechanical properties have been frequently investigated to establish the change due to neutron irradiation, because this affects the durability of the fuel containers in nuclear reactors. For that purpose, changes in structure, texture, etc., due to irradiation had to be determined; the structural properties of nonirradiated samples also had to be studied in ...
To simulate radiation damage under a future Spallation Neutron Source (SNS) environment, irradiation experiments were conducted on a candidate 9Cr-2WVTa ferritic/martensitic steel using the Triple Ion Facility (TIF) at ORNL. Irradiation was conducted in single, dual, and triple ion beam modes using 3.5 MeV Fe{sup ++}, 360 keV He{sup +}, and 180 keV H{sup +} at 80, 200, and 350{degrees}C. These irradiations produced various defects comprising black dots, dislocation loops, line dislocations, and gas bubbles, which led to hardening. The largest increase in hardness, over 63 %, was observed after 50 dpa for triple beam irradiation conditions, revealing that both He and H are augmenting the hardening. Hardness increased less than 30 % after 30 dpa at 200{degrees}C by triple beams, compatible with neutron irradiation data from previous work which showed about a 30 % increase in yield strength after 27.2 dpa at 365{degrees}C. ...
In light water reactors, austenitic stainless steels (SSs) are used extensively as structural alloys in reactor core internal components because of their high strength, ductility, and fracture toughness. However, exposure to high levels of neutron irradiation for extended periods degrades the fracture properties of these steels by changing the material microstructure (e.g., radiation hardening) and microchemistry (e.g., radiation-induced segregation). Experimental data are presented on the fracture toughness and crack growth rates (CGRs) of wrought and cast austenitic SSs, including weld heat-affected-zone materials, that were irradiated to fluence levels as high as {approx} 2x 10{sup 21} n/cm{sup 2} (E > 1 MeV) ({approx} 3 dpa) in a light water reactor at 288-300 C. The results are compared with the data available in the literature. The effects of material composition, irradiation dose, and water chemistry on CGRs under cyclic and ...
Neutron radiography and neutron radioscopy are rapidly becoming the valuable tools for nondestructive testing and basic research. The Phoenix Memorial Laboratory has developed a neutron facility capable of both film neutron radiography and real time neutron radioscopy, and has used this facility to study several phenomena of interest to the researchers in many areas. Neutrons can be used for imaging the phenomena that X-ray cannot image, such as the presence, absence or movement of hydrogenous materials inside metals such as aluminum or steel. There are three basic methods for obtaining images using neutrons: high resolution film neutron radiography, real-time neutron radioscopy and transfer film neutron radiography. The neutron radiography facility at ...
If bone strength was the only requirement of skeleton, it could be achieved with bulk, but bone must also be light. During growth, bone modelling and remodelling optimize strength, by depositing bone...Full Text Available
The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was ...
The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was ...
Presented are results of a test of a method for measuring neutron fluences using detectors with fissionable nuclides. The investigations show the soundness of of using neutron-activation detectors of the type Am for mesurements in nuclear installations for values of thermal-neutron fluence of from 10/sup 13/ to 10/sup 20/ neutrons/cm/sup 2/ with exposure for up to several months. The proposed method can be used for prolonged measurements in strong fields of both thermal and fast neutrons.
This report discusses the following topics: Prompt fission neutron energy spectra for {sup 235}U and {sup 239}Pu; Two-parameter measurement of nuclear lifetimes; ``Black`` neutron detector; Data reduction techniques for neutron scattering experiments; Inelastic neutron scattering studies in {sup 197}Au; Elastic and inelastic scattering studies in {sup 239}Pu; and neutron induced defects in silicon dioxide MOS structures.
Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)
Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)
... 500 ppm, boron increases the 0.2% offset strength; results show that boron doping does not appreciably affect ultimate compressive strength; for 0 ...
Ultimate compressive strength and failure modes were studied using 24- ... to 81 % of the average ultimate compressive strength (UCS). Figure 1 (a) is the failure ...
A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.
Optimal neutron energy for boron neutron capture therapy (BNCT) has been studied. Epithermal neutron is superior to thermal neutrons in treating deep-seated tumors. Design of the epithermal neutron column for BNCT has been performed by using a two-dimensional transport calculation code. Aluminum and heavy water are used as moderation materials. A thermal neutron column is also designed using heavy water as thermalization material. The configuration of the facility for treatment and research of BNCT and also for basic radio-biological studies of neutrons has been presented.
Optimal neutron energy for boron neutron capture therapy (BNCT) has been studied. Epithermal neutron is superior to thermal neutrons in treating deep-seated tumors. Design of the epithermal neutron column for BNCT has been performed by using a two-dimensional transport calculation code. Aluminum and heavy water are used as moderation materials. A thermal neutron column is also designed using heavy water as thermalization material. The configuration of the facility for treatment and research of BNCT and also for basic radio-biological studies of neutrons has been presented. (author).
We consider the embedding of the Standard Model fields in a$(4+d)$-dimensional theory while gravitons may propagate in $d'$ extra, compactdimensions. We study the modification of strengths of the gravitational andgauge interactions and, for various values of $d$ and $d'$, we determine theenergy scale at which these strengths are unified. Special cases where theunification of strengths is characterized by the absence of any hierarchyproblem are also presented.
... and testing of unidirectional composites, there are serious doubts about the possibility of obtaining a true ultimate compressive strength for this kind ...
Coke strength increases in significance as blast furnace and metallurgical plant gain in size and output requirement. The article underlines the need to apply error computation standards to strength testing routines. The mean square deviation was found for cokes from different plants, related to a single strength determination for M25 and M10, and amounted to 0.61 and 0.35% respectively. The future standards should include a correlation factor for permitted tolerance as between parallel determinations.
This paper presents the results of single-fiber pullout tests for deformed and smooth steel fibers embedded in the newly developed very-high strength concrete (VHSC) matrixes. The pullout test program involved four types of steel fibers, eight compressive strengths of VHSC matrixes, and two normal concrete strengths. Test results have shown that pullout behavior of different steel fiber reinforced VHSC composites is influenced by the matrix strength and fiber end condition (smooth, flat end, or hooked). Results reveal that both maximum pull-out load and total pullout energy increases as matrix strength increases for all deformed fibers that did not rupture. The test results also indicated that the increase in total pullout energy is more significant than that in peak load.
Neutron-induced soft error rates (SER`s) of subhalf-micron CMOS SRAM and Latch circuits were studied both experimentally and analytically to investigate cosmic ray neutron-induced soft errors (SE`s). Because the neutron beam used in the measurement has an energy spectrum similar to that of sea-level atmospheric neutrons, the SER data corresponds to those induced by cosmic ray neutrons. The {alpha}-particle induced SER`s were also measured for comparison with the neutron-induced SER`s. Neutron-induced SE`s occurred in both circuits. On the other hand, {alpha}-induced SE`s occurred in SRAM, but not in the Latch circuit. The measured SER`s agreed with simulated results. The authors discussed the significance of how cosmic ray neutrons affects CMOS circuits at ground level.
Gamma-ray spectrometric analysis was employed to determine the nuclides formed in thorium by neutron irradiation. Thorium sample was irradiated by neutron from a pure thermal neutron field, neutron field of Cd ratio of about 4, and epithermal neutron field, respectively. The former irradiation was carried out in a thermal neutron column provided for medical uses of neutrons, and the latters were done in the F-ring position of TRIGA II research reactor of Musashi Institute of Technology. The gamma-ray spectra were obtained and analyzed by employing a fully automatic gamma-ray analysis system named ''GAMA: giant frog:-SYSTEM'' developped by Musashi Institute of Technology. The formation of Pa-233 (U-233) was discussed quantitatively with respect to the difference of the neutron field. (author).
The detection efficiency of a lithium glass detector was calculated using MCNP code, and the calculation was compared with the published results in Pulsed Sphere Plan. A lithium glass detector of our own was made, and its neutron efficiency was calculated. The calculated neutron efficiency was verified with both pulsed and steady DD neutrons. Characteristics of Neutron response of "6Li detector was discussed. (authors)
This paper reviews the effects of neutron irradiation on thermal and mechanical properties and bulk tritium retention of armour materials (beryllium, tungsten and carbon). For each material, the main properties affected by neutron irradiation are described and the specific tests of neutron irradiated armour materials under thermal shock and disruption conditions are summarized. Based on current knowledge, the expected thermal and structural performance of neutron irradiated armour materials in the ITER plasma facing components are analysed.
A thermal neutron imaging facility for computed tomography and real-time neutron radiography is being developed at the University of Texas at Austin. The TRIGA reactor is a graphite-reflected Mark It pool-type research reactor. The neutron imaging facility will use beam port, which is at one end of a through part. Monte Carlo calculations were used to design the neutron collimator for this facility.
The Albedo Theory was applied in order to develop an one-group algorithm for coupled neutron-gamma shielding calculations. The configuration analyzed consists of multilayered plane systems, where a incident neutron current generates gamma radiation through neutron-gamma reactions. The results obtained by Albedo Method and ANISN code have shown excellent agreement. (author)
A high-purity, intense, fast-neutron source has been developed at our laboratory. We describe two inexpensive, straightforward methods of determining the total number of neutrons produced and we review precautions to be taken in applying these methods. (orig.).
Neutron radiography is a non-destructive test method to examine a material by using the dependency of neutron attenuation on the nuclear characteristics of the atoms composing the object material. There are two categories of neutron radiography; static neutron radiography and dynamic neutron radiography. The static neutron radiography is a technique to observe a standing object by using a camera or a film cassette. The dynamic neutron radiography(DNR) is a technique to observe a moving object usually by using a camera. Depending on the camera frame rate, the dynamic neutron radiography is categorized into the real time neutron radiography(RTNR) and the high speed neutron radiography(HSNR). The frame rate for RTNR is 30 frames/s and that for HSNR is usually more that 500 ...
Neutron radiography is a non-destructive test method to examine a material by using the dependency of neutron attenuation on the nuclear characteristics of the atoms composing the object material. There are two categories of neutron radiography; static neutron radiography and dynamic neutron radiography. The static neutron radiography is a technique to observe a standing object by using a camera or a film cassette. The dynamic neutron radiography(DNR) is a technique to observe a moving object usually by using a camera. Depending on the camera frame rate, the dynamic neutron radiography is categorized into the real time neutron radiography(RTNR) and the high speed neutron radiography(HSNR). The frame rate for RTNR is 30 frames/s and that for HSNR is usually more that 500 ...
Effects associated with the temperature dependence of the level density parameter, a(T), are investigated in connection with neutron evaporation processes. Different approximations, for this temperature dependence, are compared for the case of neutron emission from the compound nucleus /sup 209/Pb.
It is shown that a natural consequence of the binary pulsar's evolution is a neutron star collision. Such a collision is expected to eject neutron-rich matter of an r-process character. Taking reasonable estimates for the number of such events over the history of the galaxy, it may be that they account for all of the r-process nuclei.
Increased nitrogen levels have been correlated with decreased ductility and elevated ductile-to-brittle transition temperature in pressure vessel steels [1]. However, the exact role played by nitrogen in the embrittlement of steels remains unclear. Miller and Burke have reported atom probe ion microscopy findings from neutron-irradiated low-alloy pressure vessel steel showing the presence of a 1 to 2 ruonolayer thick film of Mo, N, and C at prior austenitic grain boundaries (GB's) [2], suggesting a role for nitrogen as an intergranular embrittler. It is of interest for the development of mitigation strategies whether nitrogen must combine with other impurities to form nitride precipitates in order to exert an embrittling effect. Briant et al [1] have associated the embrittling effect of N in steels exclusively with intergranular nitride formation. This association suggests that high nitrogen levels may be acceptable if nitride precipitation at grain ...
A core competency is a distinguishing integration of capabilities which enables an organization to deliver mission results. Core competencies represent the collective learning of an organization and provide the capacity to perform present and future missions. Core competencies are distinguishing characteristics which offer comparative advantage and are difficult to reproduce. They exhibit customer focus, mission relevance, and vertical integration from research through applications. They are demonstrable by metrics such as level of investment, uniqueness of facilities and expertise, and national impact. The Oak Ridge National Laboratory (ORNL) has identified four core competencies which satisfy the above criteria. Each core competency represents an annual investment of at least $100M and is characterized by an integration of Laboratory technical foundations in physical, chemical, and materials sciences; biological, environmental, and social sciences; engineering sciences; and ...
Full text of publication follows: Low activation ferritic/martensitic steels are receiving a high priority in the European long term materials research. Although extensively investigated, the available experimental data do not cover all required parameter ranges and cannot unambiguously be used to produce hardening/embrittlement trend curves. Therefore, the main objective of this work is to provide a physically-based engineering model offering a rational to experimental observations. From the literature, experimental data were selected to establish a database that mainly consists of 8 to 9Cr-steels irradiated in the range of 50 to 600 deg. C up to 30 dpa and with a He-content up to 5000 appm. The database includes neutron and proton irradiations, He-implanted as well as B- and Ni-doped steels. Because of the difficulty of interpretation inherent to the Charpy impact test, only tensile data were considered. The difficulty stems from the large range of specimen sizes ...
A black neutron detector of novel design has been constructed and tested as a neutron flux monitor. The neutron time-of-flight (TOF) technique was used to measure the zero degree neutron spectrum from a subnanosecond pulsed proton beam on a thick metallic lithium target. We describe the detector, discuss the shielding arrangement and electronics, determine the low-energy cut-off. We calculate the efficiency, show spectra and compare measured zero degree differential cross-section of the {sup 7}Li(p, n{sub 0}){sup 7}Be reaction with recommended published cross-sections. (orig.).
Because of limitation on neutron-incident data, it is difficult to obtain global optical model potential for neutrons. In contrast, there are some global optical model potentials for proton in detail. It is interesting to convert the proton-incident global optical potentials into neutron-incident ones. In this study we introduce (N-Z)/A dependent symmetry potential terms into the global proton-incident optical potentials, and then obtain neutron-incident ones. The neutron potentials reproduce total cross sections in an acceptable degree. However, a comparison with potentials proposed by other authors brings about a confused situation in the sign of the symmetry terms. (author).
A method and apparatus for nuclear borehole logging, and in particular, neutron porosity logging, uses a neutron source, and a pair of spaced lithium detectors, preferably Li"6I crystal or Li"6 doped glass, to detect neutrons emitted from a borehole formation being logged. The spectrum developed by the lithium detectors is processed to remove the gamma ray background radiation and the hydrogen absorption peak, thus allowing a more accurate neutron count. A Gaussian curve is fitted to the neutron peak of the spectrum, the curve eliminating the hydrogen absorption peak. The area under this Gaussian curve represents the neutron count. (author).
The introduction prior to series of papers on the application of neutrons for materials science (MS) in this issue starts with a brief summary of neutron scattering research history in Japan; from the individual activity by Motoharu Kimura at RIKEN early around 1940s to those at present era of world leading neutron science facilities of both JRR3 research reactor and JPARC of the largest proton Accelerator complex in Tokai. Then physical properties of low energy neutrons applied to MS as well as such neutron sources are also reviewed (http://www.jstage.jst.go.jp/browse/jvsj2). (author)
Determination of thermal to fast neutron flux ratio (ffast) and fast neutron flux (phi-fast) is required for fast neutron reactions, fast neutron activation analysis, and for correcting interference reactions. The ffast and subsequently phi-fast were determined using the absolute method. The ffast ranged from 48 to 155, and the phi-fast was found in the range 1.03x1010-4.89x1010 n cm-2 s-1. These values indicate an acceptable conformity and applicable for installation of the fast neutron facility at the MNA research reactor.
Thermal neutron beam from the TNRF of JRR-3M was utilized for detection of mice lung cancer in vivo. Both the static and real-time neutron imaging were tried. Very strong thermal neutron beam is necessary to detect lung cancers because small changes are hidden by the very large attenuation of thermal neutron beam by the hydrogens in the tissues. The detection was successfully performed. Especially, the Super Eye of Hamamatsu Photonics contributed very effectively. Bone marrows and cartilages were also shown clearly. If an efficient and compact neutron source will become available in future, this method will grow up as a powerful tool for biomedical application. (author).
A neutron collimator system is being designed as part of a neutron imaging facility for computed tomography and real-time neutron radiography research at the through beam port of the University of Texas TRIGA reactor. Lack of sufficient information about collimator systems in a through port from the literature necessitated the use of Monte Carlo calculations using the MCNP code 3 to search for optimal design configuration and materials that maximize the thermal neutron intensity at the image plane while minimizing the fast neutrons and gamma radiation.
The dosimetry for radiotherapy involving neutrons is very complicated, owing to the complexity of secondary radiation components, whose contributions to the total absorbed dose have to be discriminated, owing to the different radiobiological effects. In order to separate thermal neutrons and photons, LiF dosimeters are mostly utilized. containing different percentage of Li, like as TLD-700, TLD-100 and TLD-600, but many problems arise. In the response of TLD-700 exposed to neutron-gamma mixed fields with high neutron flux, the contribution of thermal neutrons to the Tl emission is high. Moreover. TLD-100 and TLD-600 may undergo radiation damage, and great care has to be taken in order to obtain reliable results. Other TLDs showing lower sensitivity to neutrons are proposed and experimented for such high-flux neutron fields. The faced ...
A prediction of delayed neutron yields for actinides which are important in the nuclear energy field is given. The prediction is based on a correlation related to a suggested cluster structure of the nucleus. (author).
Neutron yield from the "6","7Li + d reaction has been investigated. The results obtained are compared with the published data with some theoretical models.
The delayed neutrons from neutron-induced fission in /sup 232/U, /sup 237/Np, /sup 238/Pu, /sup 241/Am, /sup 242/Am/sup m/, /sup 245/Cm, and /sup 249/Cf were studied for the first time; those from /sup 232/Th, /sup 233/U, /sup 235/U, /sup 238/U, /sup 239/Pu, /sup 241/Pu, and /sup 242/Pu were measured again. The data were used to develop an expression for the prediction of the absolute delayed neutron yield, and the prediction of delayed neutron emission with time. This approach accurately predicts observed delayed neutron yields and decay characteristics. A fission product yield model was used in conjunction with delayed neutron emission probability to analytically predict delayed neutron characteristics. The results of this analysis are in excellent agreement with experimental values.
The measurements of the total delayed neutron yield from fast neutron induced fission of sup 2 sup 3 sup 8 U were made. The experimental method based on the periodic irradiation of the fissionable sample by neutrons from a suitable nuclear reaction had been employed. The preliminary results on the energy dependence of the total delayed neutron yield from fission of sup 2 sup 3 sup 8 U are obtained. According to the comparison of experimental data with our prediction based on correlation properties of delayed neutron characteristics, it is concluded that the value of the total delayed neutron yield near the threshold of (n,f) reaction is not a constant.
It is shown numerically that on a time scale of order 1 msec a neutron star with pion condensation will undergo separation into a core and an envelope with a sharp interface. The envelope will not, however, be ejected.
A new high strength titanium alloy has been developed primarily intended for fastener applications. While Ti-6Al-4V is used extensively as a fastener alloy in the aerospace industry, its shear strength allowable is limited to 655 MPa (95 ksi). For higher shear strength requirements, various steels or nickel-based alloys are used (up to 860 MPa (125 ksi)), but with the attendant density penalty. This new alloy is intended to provide the 860 MPa shear strength at roughly a 40% weight savings. After screening various alloy systems, the optimum chemistry has been selected as follows: Ti-6.0V-6.2Mo-5.7Fe-3Al. In light of its 125 ksi shear strength goal, the alloy has been designated TIMETAL reg-sign 125.
Tailor die quenching in the hot stamping of quenchable steel sheets was developed to produce ultra-high strength steel formed parts having strength distribution. Local portions of the heated sheet were quenched by holding grooved tools at the bottom dead centre during the stamping. Non-contact portions were generated in the sheet by grooving the tools, and thus the strength in the contact portions is high owing to the quenching and that in the non-contact portions is low owing to the lack of the quenching. Hat-shaped products having a tensile strength of approximately 1.5GPa only at four corners were formed.
Ribbon parachute fabrics were tested during development and production of a 24 ft parachute, and after 2.5 years ambient exposure at several storage sites. The effects of sewing, packing, and parachute deployment on material strength were obtained in the 1000 lb Kevlar ribbon after moisture exposure during packing, and when packed parachutes absorbed moisture or were thermal cycled. Individual yarn samples from the low strength ribbons exhibited little change in strength indicating that the material itself had not degraded. Factors leading to the change in ribbon strength are discussed. Considering all materials, there have been no indications to date of any uncontrollable changes in material strength that would limit the use of Kevlar in parachute applications.
This paper deals with steel fiber reinforced concrete mechanical static behaviour and with its classification with respect to fibers content and mix-design variations. A number of experimental tests were conducted to investigate uniaxial compressive strength and tensile strength. Different mixtures were prepared varying both mix-design and fiber length. Fibers content in volume was of 1% and 2%. Mechanical characterization was performed by means of uniaxial compression tests with the aim of deriving the ultimate compressive strength of fiber concrete. Four-point bending tests on notched specimens were carried out to derive the first crack strength and the ductility indexes. The tensile strength of steel fiber reinforced concrete (SFRC) was obtained both from an experimental procedure and b...
The Inner Model Hypothesis (IMH) and the Strong Inner Model Hypothesis (SIMH) were introduced by the first author in ``Internal consistency and the inner model hypothesis'', Bulletin of Symbolic Logic, December 2006. In this article we establish some upper and lower bounds for their consistency strength.
The purpose of this study was to determine if there were any beneficial or detrimental effects regarding delayed onset muscle soreness (DOMS), serum creatine kinase (CK), and maximum concentric strength...Full Text Available
From this literature study it was found that ferrocement is a composite material of superior mechanical properties when compared to reinforced concrete. This superiority is reflected in greater flexural crack strength, tensile strength, ductility, and imp...
Isometric/isokinetic muscle strength and isokinetic endurance of the lower extremities as well as aerobic capacity were evaluated in 67 patients (43 female, 24 male; mean age 53 years, range 23-65)...Full Text Available
OBJECTIVES: The ability to maximally generate active muscle tension during resistance training has been established to be a primary determinant for strength development. The influence of intrasession...Full Text Available
Strain rate effects for the high strength, metastable beta-titanium alloy Ti-8Mo-8V-2Fe-3Al are assessed in terms of tensile and fracture toughness behavior. It is shown that as the strain rate increases the yield strength, ultimate tensile strength, and ductility also increase. As a result of the decrease in the amount of intergranular fracture as the strain rate is increased, the dynamic fracture toughness values K/sub Id/ are greater than those obtained under static conditions as given by K/sub Q/.
The ultimate compressive strength of 36 thoracolumbar vertebrae was determined experimentally. In addition, the trabecular bone mineral content was measured by single energy quantitative computed tomography. The areas of fractured endplates were also determined by computed tomography. The results show that a linear relationship exists between the compressive strength and the product of bone density and endplate area. These data allow an in vivo prediction of vertebral body strength using a noninvasive method with a standard error of estimate amounting to less than 0.95 kN. PMID:3212488
Ultimate Compressive Strength of Short Sheet-Stringer Panels With Special. Reference to the Influence of the Riveted Connection Between Sheet and. Stringer ...
... Problems investigated in various basic hollowness ratios include ultimate compressive strength, fatigue properties, buckling characteristics, and ...
Stress-rupture strength tests were made of metal steam pipe (12Kh1MF steel) in various conditions, the original, after aging under laboratory conditions (580{degrees}C, 10,000 h), and after long service. It was shown that the more the steel is hardened by heat treatment or cold plastic working in the original condition, the less it hardens in creep. It was established that softening in creep of steel with a moderate yield strength is caused primarily by aging and with a high yield strength by pore formation.
Recent developments in design and production of thermal neutron detectors based on a crystalline Si diode coupled to a Gd converter are reviewed. The most significant results of neutron test measurements carried out on prototype systems and pointing out the performances of the device are reported. Progress through various detection schemes and technological solutions for the production of a real time neutron counter for routine operation are outlined.
Neutron Science Project was started at Japan Atomic Energy Research Institute since 1996 for promoting futuristic basic science and nuclear technology utilizing neutrons. For this purpose, research and developments of intense proton accelerator and spallation neutron target were initiated. The present paper describes the current status of such research and developments. (author)
The characteristics of real-time neutron radiography are described briefly in this paper, and the acquirement of neutron flux, the selection of convertor and the structure of the twilight imaging system and the image-sampling and image-processing system in SPRR-300 reactor are also analyzed detailedly. The experimental result of real-time neutron radiograph is too analyzed in this paper
We describe the continued development of a portable, real-time neutron spectrometer. The spectrometer is composed of two distinct detector systems: a Helium 3 gas filled proportional counter for the lower neutron energy interval between 20 KeV and 2 MeV and a bulk silicon solid state detector for the higher energy interval between 2 MeV and 500 MeV. Modeling and experimental results with mono-energetic neutron beams are reported.
Isospin-breaking effects in the baryonic sector are studied in the framework of a medium-modified Skyrme model. The neutron-proton mass difference in infinite, asymmetric nuclear matter is discussed. In order to describe the influence of the nuclear environment on the skyrmions, we include energy-dependent charged and neutral pion optical potentials in the s- and p-wave channels. The present approach predicts that the neutron-proton mass difference is mainly dictated by its strong part and that it strongly decreases in neutron matter. (orig.)
A 68 MeV neutron transmission experiment on iron has been analyzed with MCNPX using the Los Alamos LA150 neutron data library, the ECN/BRC 150 MeV neutron data library and with the intranuclear cascade code LAHET. The clear improvement of using the data libraries is confirmed. Also, other materials present in LA150 have been checked using the same MCNPX set-up. 10 refs.
In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)
In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)
The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computed tomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux measured at the inlet of ...
The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computed tomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux measured at the inlet of ...
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere.
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere
The Albedo Theory was applied in order to develop an one-group algorithm for coupled neutron-gamma shielding calculations. The configuration analyzed consists of multilayered plane systems, where a incident neutron current generates gamma radiation through neutron-gamma reactions. The results obtained by Albedo Method and ANISN code have shown excellent agreement. (author)
A multi-group neutron-gamma cross-section library in DTF-IV format is supplemented with electron production matrix to generate a coupled neutron-gamma-electron library. This is realized by estimating the contributions from Compton scattering, pair production and photoelectric effect to the electron production cross-sections. A novel application of this new library, which involves transport of neutrons, gammas and electrons, for estimating the Compton current due to a pulse of radiation in air is discussed.
A multi-group neutron-gamma cross-section library in DTF-IV format is supplemented with electron production matrix to generate a coupled neutron-gamma-electron library. This is realized by estimating the contributions from Compton scattering, pair production and photoelectric effect to the electron production cross-sections. A novel application of this new library, which involves transport of neutrons, gammas and electrons, for estimating the Compton current due to a pulse of radiation in air is discussed.
In calculating the strengths of depolarizing resonances it may be convenient to reformulate the equations of spin motion in a coordinate system based on the actual trajectory of the particle, as introduced by Kondratenko, rather than the conventional one based on a reference orbit. It is shown that resonance strengths calculated by the conventional and the revised formalisms are identical. Resonances induced by radiofrequency dipoles or solenoids are also treated; with rf dipoles it is essential to consider not only the direct effect of the dipole but also the contribution from oscillations induced by it.
The mechanical properties of TS 6 (Ti--10 percent Cr--7 percent V--3.5 percent Mo--3 percent Al) alloy were studied. Results are presented in plots showing yield stress vs cold work, notched tensile strength vs unnotched tensile strength, and ultimate tensile strength vs test temperature.
Cyclic strength of #alpha#+#beta#-titanium alloy BT3-1 is studied under load frequencies of 33 and 300 Hz. The increase in the cyclic strength with growing frequency is caused by formation of FCC interphase layers of titanium hydrides. Their formation is one of possible ways of raising the fatigue strength of titanium alloys. Peculiarities of FCC interlayer formation in #alpha#+#beta# phases under loading frequency variation are revealed.
The applicability of conventional strength hypotheses in the long-term creep range was examined by means of multiaxial loaded small and large-scale specimens of 1% CrMoNiV-steel at 550deg C. The experimentally determined deformation behaviour in the primary and secondary creep range was simulated by means of a finite element analysis. The creep deformation capacity is influenced by the degree of multiaxiality. The validity of a strength hypothesis depends on the type of load and on deformation resp. failure criteria. (orig.).
To get a considerable reduction of the radiotoxicity due to americium, a thermal neutron fluence of 2.10{sup 22} cm{sup -2} or a fast neutron fluence of 2.10{sup 24} cm{sup -2} is required. Irradiation in a thermal neutron flux leads to lower masses of {sup 234}U and precursors and of {sup 237}Np and precursors, but to higher curium masses and much higher neutron emission rates than irradiation in a fast neutron flux. Therefore, irradiation in a fast neutron flux has preference when multiple recycling is adopted. When once-through burning is applied, irradiation in a thermal neutron flux can be applied. Then irradiation in a heavy water reactor (HWR) has preference above irradiation in a PWR or in a high temperature gas-cooled reactor (HTGR). (authors) 4 refs.
To get a considerable reduction of the radiotoxicity due to americium, a thermal neutron fluence of 2.10{sup 22} cm{sup -2} or a fast neutron fluence of 2.10{sup 24} cm{sup -2} is required. Irradiation in a thermal neutron flux leads to lower masses of {sup 234}U and precursors and of {sup 237}Np and precursors, but to higher curium masses and much higher neutron emission rates than irradiation in a fast neutron flux. Therefore, irradiation in a fast neutron flux has preference when multiple recycling is adopted. When once-through burning is applied, irradiation in a thermal neutron flux can be applied. Then irradiation in a HWR has preference above irradiation in a PWR or in a HTGR. (orig.).
An explanation is given of what a loop heat pipe (LHP) is, and how it works. It is then shown that neutron imaging (both real time neutron radioscopy and single exposure neutron radiography) is an effective experimental tool for the study of LHPs. Specifically, neutron imaging has helped to identify and correct a cooling water distribution problem in the condenser, and has enabled visualization of two-phase flow (liquid and vapor) in various components of the LHP. In addition, partial wick dry-out, a phenomenon of great importance in the effective operation of LHPs, is potentially identifiable with neutron imaging. It is anticipated that neutron radioscopy and radiography will greatly contribute to our understanding of LHP operation, and will lead to improvement of LHP modeling and design. PMID:15246420
An explanation is given of what a loop heat pipe (LHP) is, and how it works. It is then shown that neutron imaging (both real time neutron radioscopy and single exposure neutron radiography) is an effective experimental tool for the study of LHPs. Specifically, neutron imaging has helped to identify and correct a cooling water distribution problem in the condenser, and has enabled visualization of two-phase flow (liquid and vapor) in various components of the LHP. In addition, partial wick dry-out, a phenomenon of great importance in the effective operation of LHPs, is potentially identifiable with neutron imaging. It is anticipated that neutron radioscopy and radiography will greatly contribute to our understanding of LHP operation, and will lead to improvement of LHP modeling and design.
An explanation is given of what a loop heat pipe (LHP) is, and how it works. It is then shown that neutron imaging (both real time neutron radioscopy and single exposure neutron radiography) is an effective experimental tool for the study of LHPs. Specifically, neutron imaging has helped to identify and correct a cooling water distribution problem in the condenser, and has enabled visualization of two-phase flow (liquid and vapor) in various components of the LHP. In addition, partial wick dry-out, a phenomenon of great importance in the effective operation of LHPs, has been identified with neutron imaging. It is anticipated that neutron radioscopy and radiography will greatly contribute to our understanding of LHP operation, and will lead to improvement of LHP modeling and design.
A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)
A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)
The neutron radiography facility was installed at the tangential beam port of the 3 MW TRIGA MARK-II research reactor. In the facility only direct film neutron radiography method is being used. The project involves development of electronic imaging system for real time neutron radiography in the existing facility with the aim of utilizing it for research and industrial applications. In establishing the electronic imaging system for real time neutron radiography the improvements of existing facility were almost done during this period. In parallel, the former facility was used for the research: (a) A study of wood and wood plastic composites with and without additive by using film neutron radiography and (b) A study of jute reinforced polymer composites by using film neutron radiography technique. (author)
The registration of secondary cosmic ray neutrons is a convenient tool for the investigation of primary cosmic ray variations and for meteorological effects as well. At present a large network of neutron monitors exists, aiming at studies of cosmic ray variations which are related to interplanetary conditions and geomagnetic activity. At the same time cosmic ray variations may be related to some atmospheric processes. In this connection, using the data from two neutron monitors (a standard and a lead free one), a gamma detector from Moscow station and lead free neutron monitor at BEO Moussala, we studied the correlations between rain flows and neutron flux. In this study we used daily averages on the basis of 10 min data for the neutron flux, corrected for barometric pressure and data from local meteo-stations. The preliminary analysis indicates a correlation ...
The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible ...
The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of monitoring any changes in the real-time ...
By using this doping method, silicon semiconductors with extremely uniform dopant distributions can be produced, and this is the dominant advantage of NTD compared with a conventional chemical doping. Good uniformity of a dopant concentration is usually required for high power applications such as thyristor (SCR), IGBT, IGCT and GTO and for special sensors. Achieving an accurate neutron fluence corresponding to a target resistivity as well as a uniform irradiation is the prime target of a neutron irradiation for NTD. Generally, in order to reach an accurate neutron fluence, a real time neutron flux is monitored by a neutron detector such as a Self-powered Neutron Detector(SPND). And, after an irradiation, the total irradiation fluence is confirmed by measuring the absolute activity of a neutron activation sample that has been irradiated with ...
Manned-space missions bring an exposure due to corpuscular radiations of which nature is quite different from what we encounter in the ground environment. In the space environment, many secondaries are produced through interactions of cosmic ray primaries with the spacecraft wall and other surrounding materials. Among this large variety of radiation components in the space, the contribution of neutrons to the radiation exposure of astronauts has remained to be studied. Up to today, efforts to measure neutron dose equivalent have been made using passive detector systems. Considering uncertainties involved in current measurements and estimations of high energy neutrons, and their increasing importance for future manned missions, it is necessary to measure neutron spectrum in the spacecraft under realistic conditions. The neutron spectra have never been measured on board a spacecraft, ...
Neutron semiconductor detectors for neutron counting and neutron radiography have an increasing importance. Simple silicon neutron detectors are combination of a planar diode with a layer of an appropriate neutron converter such as 6LiF. These devices have limited detection efficiency of not more than 5%. The detection efficiency can be increased by creating a 3D microstructure of dips, trenches or pores in the detector and filling it with a neutron converter. The first results related to the development of such devices are presented. Silicon detectors were fabricated with pyramidal dips on the surface covered with 6LiF and then irradiated by thermal neutrons. Pulse height spectra of the energy deposited in the sensitive volume were compared with simulations. The detection efficiency of these devices was about 6.3%. Samples with different ...
{sup 14}C is a is a long-lived beta-emitting nuclide (T{sub 1/2} = 5730 years) produced naturally in the upper atmosphere as a result of reactions between neutrons and stable {sup 14}N({sup 14}N(n,p){sup 14}C). Although in a lesser extent, nuclear power plants produce {sup 14}C as well during their routine operation. Since it is converted in {sup 14}CO{sub 2} and mixed throughout the atmosphere, it is incorporated into plant tissues, via photosynthesis process, and hence in food chain. Because of the biological importance of {sup 14}C and long half-life, it is of interest to quantify the amounts released by nuclear industry. The Brazilian nuclear central named Nuclear Central Admiral Alvaro Alberto (CNAAA) has two nuclear reactors of PWR type in operation, Angra I (657 MWe) and Angra II (1350 MWe), and one under construction, Angra III (1309 MWe PWR). The aim of this study was to determine the strength of the sources and the {sup 14}C content ...
The applications of neutron reflectometry to study dynamic phenomena at surface and interfaces have been restricted so far. This was mainly due to the low intensity of neutron sources, but now high-intensity spallation neutron sources are under construction in Japan (J-PARC) and US (SNS). We are planning to install a spin-echo option on the J-PARC neutron reflectometer with horizontal sample geometry for studies of dynamics of surfaces and interfaces. This option is based on the resonance spin-echo method and aimed at dynamics up to hundreds of nanoseconds. In this contribution, the plan and status of development are introduced together with the principle and characteristics of this option.
The polarized triple-axis spectrometer TASP at SINQ has been optimized for measuring magnetic cross sections in condensed matter. The neutrons are polarized or analyzed either by means of benders or Heusler monochromators. The beam divergence, i.e. the intensity, and the spectral range of the neutrons is rather large because of the supermirror coatings of the feeding neutron guide. The intensity can be further increased at the sample position by means of a focussing monochromator and a focussing anti-trumpet. The end position of TASP allows the tailoring of the neutron beam already before the monochromator and to scatter neutrons over very wide ranges of angles. (author) 6 figs., 1 tab., 8 refs.
A helium-3 proportional detector was equipped with the experiment of Liaw-type electrolytic cell contained eutectic LiCl-KCl molten salt saturated by LiD electrolytic to collect the informations of the rate and the energy distribution of possible neutron produced during the electrolysis processes. For long time monitoring, the significant reproducible neutron bursts appeared at several runs of cells during electrolytic processing. The neutron counting rate increased about a factor of two above the level of the background measurement. The pulse height signals were verified of neutron energy ranging from thermal up to 350 keV. (author).
A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.
Measurements were made of the cross section for /sup 242/Am/sup m/ fission induced by neutrons in the energy range 0.04< or =E/sub n/< or =4.52 MeV as well as by neutrons with E/sub n/roughly-equal14.8 MeV. An electrostatic generator and a low-voltage accelerating tube were used to generate the quasimonochromatic neutrons. Measurements in the low-energy region were made by using the time-of-flight technique in neutrons from a nuclear explosion. Results of the measurements are compared with previously published data.
A Si array neutron detector is proposed based on commercial CCD and CMOS sensor technology coupled with a thin film neutron conversion coating. System sensitivity is estimated for a baseline device containing a single array and various schemes to increase detection probability by simple area scaling and stacking are discussed. Some possible use scenarios are discussed involving static and moving sources. Likely neutron source fluxes for weapons grade and commercial grade nuclear material are estimated along with expected intensities of cosmic background neutrons which would establish a noise floor to detection limits.
This paper analyzes fission neutron multiplicity for the /sup 242m/Am(n,f) reaction. The fission neutron multiplicity, v bar, of /sup 242m/Am(n,f) was measured relative to that of /sup 235/U(n,f) using the neutron time-of-flight facility at the Lawrence Livermore National Laboratory 100-MeV electron Linac. A comparison of the measured energy dependence of v-bar is made with semi-empirical models of neutron emission from the actinides. 22 refs.
A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.
Inelastically scattered neutron spectra and angular distributions measured for a number of nuclei at the 9.1 and 14.4 MeV incident neutron energies are fitted well as a sum of neutron evaporation spectrum and the direct interaction part. For the last one the practical scheme of parametrization based on direct interaction theory is presented. The relative contribution of direct interactions in double differential cross sections and parameters of neutron evaporation spectra have been evaluated. All results have a simple physical interpretation and may be useful at interpolating of data in a wide energy interval.
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter.
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).
The bone mineral content of 109 lumbar vertebrae from 36 different subjects was determined by dual photon absorptiometry. The mean age of the subjects was 58.5 years (range, 31 to 79 years). The ultimate strength of the vertebral bodies was determined during axial compression. Bone mineral content and ultimate compressive strength were correlated (r = 0.86) and the strength was found to increase linearly with increasing amounts of bone mineral content. No differences in this correlation were found in the four vertebral levels (L-4) included in the study, but a difference in this correlation was found between specimens taken from male and female subjects. The results make it possible to estimate the strength of a vertebral body from the knowledge of its bone mineral content as determined by dual photon absorptiometry and provide a basis of estimations of normal and abnormal amounts of bone mineral ...
A new experimental technique to measure material shear strength at high pressures has been developed for use on magneto-hydrodynamic (MHD) drive pulsed power platforms. By applying an external static magnetic field to the sample region, the MHD drive directly induces a shear stress wave in addition to the usual longitudinal stress wave. Strength is probed by passing this shear wave through a sample material where the transmissible shear stress is limited to the sample strength. The magnitude of the transmitted shear wave is measured via a transverse VISAR system from which the sample strength is determined.
To predict the fatigue life of fiber reinforced composites, fatigue process of CFRP laminates of [0 /90 ]{sub s} is investigated and the influence of damages occurring at fiber, matrix and fiber/matrix interface on the various critical strengths and the relationship between residual critical strength and failure are discussed. As a result, it was shown that fatigue strength (i.e. fatigue life) consisted of residual critical strength and stresses occurring at each layer (0 and 90 layers) and interlayer. Moreover, the fatigue failure occurred because the residual critical strength of each layer and interlayer decreased with dependence of their microdamage densities, so that the fatigue life can be predicted by evaluating microdamage behavior in fatigue process. (orig.) 14 refs.
We study fluctuation properties of strength function phenomena by employing a quantum mechanical model where a single parent state couples with a large number of background states. The background system is devised in such a way that the classical dynamics of the system may show a regular, an irregular, or a chaotic character as a function of a single parameter. The coupling of the parent state to the background states produces a fragmentation of the parent state, giving rise to a strength function phenomenon. We study various measures of the strength function that characterize its bulk structure or fluctuation properties. They include energy moments, strength distribution, fractal dimensions of the strength function, and Fourier transform of the autocorrelation function. Some of these measures, such as strength distribution or Fourier transform of the ...
National Research Institute for Materials started in FY1966 a creep data sheet project aiming at obtaining the creep test data until 360Ms (about 11 years and half) in maximum, and has continuously been conducting the above on more than 40 kinds of heat resistant metallic materials for practical use for 30 years already as of January, 1996. The 360Ms creep rupture strength which has been aimed at by this project is the basic important strength property referred to at the time of determining design allowable stress of high temperature structural members. The Institute has published the accumulation of the test data of long range creeps lasting beyond 360Ms of the Institute as a creep data sheet, and in this article, the tremendous volume of this long range creep test data is analyzed and studied systematically, the new knowledge concerning the high temperature strength properties thereby obtained is named the base creep ...
As part of a general study of personnel neutron dosimetry systems, three British and two German TL albedo dosimeters were compared. They range from simple albedo devices to multi-element devices which detect combinations of incident and albedo neutrons. They were exposed to beams of mono-energetic neutrons, a thermal neutron column and a "2"5"2Cf source. The variation in response with neutron energy above 0.1 MeV was similar for all dosimeters. The resuls show that in general multi-component dosimeters fo not provide enough information to deduce the effective energy of incident neutrons. The choice of single or multi-element dosimeters for particular types of environment is discussed. The Harvey dosimeter has the most acceptable thermal neutron response of the simpler devices. For neutron energies below 0.5 MeV its ...
A system for real-time neutron radiography of moving objects is described. It comprise a source adapted to generate a continuous uninterrupted series of neutron pulses. Each pulse has a predetermined peak power and duration compatible with the framing times of a real-time video imaging system. A transporter moves an object to be examined to bring sequentially position selected portions of the object in the path of the pulses. Where the object itself has moving components, pulses are sequentially incident on the object. According to any dissimilarities, the object will alter the intensity of the neutrons passing therethrough. In order to record separately the changes in the neutron intensity, for each pulse, an imager is positioned to receive the neutron beam pulses which have been altered by their passage through the object and produce images indicating intensity alterations. A ...
A system for real-time neutron radiography of moving objects is described. It comprise a source adapted to generate a continuous uninterrupted series of neutron pulses. Each pulse has a predetermined peak power and duration compatible with the framing times of a real-time video imaging system. A transporter moves an object to be examined to bring sequentially position selected portions of the object in the path of the pulses. Where the object itself has moving components, pulses are sequentially incident on the object. According to any dissimilarities, the object will alter the intensity of the neutrons passing therethrough. In order to record separately the changes in the neutron intensity, for each pulse, an imager is positioned to receive the neutron beam pulses which have been altered by their passage through the object and produce images indicating intensity alterations. A ...
Within the past two and one half years of the project ``Surface Physics With Cold and Thermal Neutron Reflectometry`` a new thermal neutron reflectometer was constructed at the Rhode Island Nuclear Science Center (RINSC). It was used to study various liquid and solid surfaces. Furthermore, neutron reflection experiments were be un at different laboratories in collaboration with Dr. G.P. Fetcher (at Argonne National Laboratory), Dr. T. Russell (IBM Almaden) and Drs. S.K. Satija and A. Karim (at the National Institute for Standards and Technology). The available resources allowed partial construction of an imaging system for ultracold neutrons. It is expected to provide an extremely high resolution in momentum and energy transfer in surface studies using neutron reflectometry. Much of the work reported here was motivated by the possibility of later implementation at the planned ...
When the history of neutrons is considered, three large discoveries are recalled, that is, the discovery of neutrons by Chadwick in 1932, the discovery of the nuclear fission of uranium by Hahn and Strassmann in 1938, and the continuation of chain reaction in nuclear fission by Fermi and others in 1942. In neutron capture reaction, the reaction cross section can become very large. The fields of research, to which neutrons have contributed most as the experimental probe, are neutron activation analysis and neutron diffraction. The development of the prompt gamma ray analyzer at the JRR-3M in Japan Atomic Energy Research Institute is reported. This method eliminates the various defects in ordinary neutron activation analysis. By installing the cold neutron source with hydrogen cooling in the JRR-3M, the new field of ...
In neutron radiography, as in other forms of NDE, it is sometimes desirable to observe dynamic events. This need has generated increased interest in the development of real-time neutron radiography systems and neutron-to-light converter screens optimized for real-time application. Two screens currently available at MURR are: (1) a 0.041-cm-thick Gd_2O_2S screen manufactured by 3M Company and (2) a "6KiF-ZnS(Ag) screen (NE 426) manufactured by Nuclear Enterprises. These screens are presently used in conventional film neutron radiography and represent two of the commercially available screens that have demonstrated the greatest resolution and sensitivity. Unfortunately, these screens have severe limitations when used for real-time neutron radiography. In order to isolate and minimize the factors contributing to these limitations, several neutron absorbers and ...
A technique was developed that permits fluid flow to be visualized even where the flow is completely shrouded by metal. The technique employs real-time neutron radiography, which is similar to x-ray radiography except a collimated beam of neutrons is used. Various combinations of neutron-opaque tracer materials were tested with neutron-transparent fluid. Neutron opaque tracers, such as solid particles, fluid droplets, and streaklines were imaged through metal walls as they convected in neutron-transparent ambient fluid. Visualization of bubbles/voids were evaluated for possible future applications. Surface-flow patterns were also imaged by using neutron-opaque tufts. These techniques were evaluated for image contrast, resolution, and the ability to accurately track fluid flow fields. The techniques were also modeled to optimize contrast in ...
Delayed-neutron (DN) energy spectra following thermal neutron induced fission of /sup 239/Pu as a function of time after fission have been measured, using the beta-neutron time-of-flight (TOF) spectrometer at the University of Lowell. Thermal/epithermal neutrons were produced on the 5.5-MV Van de Graaff accelerator using the /sup 7/Li(p,n)/sup 7/Be reaction. Time spectra over the neutron energy range of 0.01-4.0 MeV were measured for seven different time intervals after fission, each interval containing varying contributions from the six delayed neutrons groups. The DN energy spectra following induced thermal fission of /sup 239/Pu are compared to those resulting from induced thermal fission of /sup 235/U for each of the seven delay time intervals. Decomposition of the measured spectra into six-group DN spectra was accomplished employing an iterative ...
The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for ...
A device for detecting neutrons includes a semi-insulated bulk semiconductor substrate having opposed polished surfaces. A blocking Schottky contact comprised of a series of metals such as Ti, Pt, Au, Ge, Pd, and Ni is formed on a first polished surface of the semiconductor substrate, while a low resistivity ("ohmic") contact comprised of metals such as Au, Ge, and Ni is formed on a second, opposed polished surface of the substrate. In one embodiment, n-type low resistivity pinout contacts comprised of an Au/Ge based eutectic alloy or multi-layered Pd/Ge/Ti/Au are also formed on the opposed polished surfaces and in contact with the Schottky and ohmic contacts. Disposed on the Schottky contact is a neutron reactive film, or coating, for detecting neutrons. The coating is comprised of a hydrogen rich polymer, such as a polyolefin or paraffin; lithium or lithium fluoride; or a heavy metal fissionable material. By varying the ...
Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in ...
This article provides a survey of neutron scattering experiments in condensed matter research, which are of interest to chemistry. The theoretical background has been treated in a previous issue. The present article consists of two parts. The first part exhibits the range of experimental possibilities by means of a few selected examples. The starting point is classical neutron diffraction by which the position of atomic nuclei may be determined. Additional information on the spatial distribution in the outer electron shells may be obtained via combined X-ray/neutron-diffraction experiments or via the diffraction of polarized neutrons. Progress in instrumentation, due to the development of more intense sources, has influenced especially the fields of small angle scattering and spectroscopy. The second part features domains of research of current interest, where a combination of several ...
The themal neutron sensitivities of SEI and Toshiba FD-P10-7 radiophotoluminescent silver activated metaphosphate glass dosimeters have been measured and studied theoretically. The graphite thermal neutron column attached to the AEEW reactor NESTOR was utilised as a source of thermal neutrons with minimal fast neutron and gamma-ray contamination. Both the neutron removal and gamma correction measurement techniques were applied and these gave consistent results. It was found that the thermal neutron sensitivity of the Toshiba dosimeters is comparable to the most neutron intensitive thermoluminescent materials available. Because of their larger size and higher silver concentration, however, SEI dosimeters are an order of magnitude more neutron sensitive. The neutron sensitivity of FD-7 glass has not ...
The themal neutron sensitivities of SEI and Toshiba FD-P10-7 radiophotoluminescent silver activated metaphosphate glass dosimeters have been measured and studied theoretically. The graphite thermal neutron column attached to the AEEW reactor NESTOR was utilised as a source of thermal neutrons with minimal fast neutron and gamma-ray contamination. Both the neutron removal and gamma correction measurement techniques were applied and these gave consistent results. It was found that the thermal neutron sensitivity of the Toshiba dosimeters is comparable to the most neutron intensitive thermoluminescent materials available. Because of their larger size and higher silver concentration, however, SEI dosimeters are an order of magnitude more neutron sensitive. The neutron sensitivity of FD-7 glass has not ...
The authors review two types of simulators for the analysis of cosmic ray neutron-induced soft errors (SE's). One of them is the neutron-induced soft error simulator (NISES). A recently proposed nuclear reaction theory forms the foundation for the nuclear reaction database used in NISES. The other simulator, the simplified simulator MBGR, is based on a modified version of the burst generation rate (BGR) model. Both simulators accurately simulate neutron-induced SE rates (SER's). MBGR actually provides an easier and quicker estimation of neutron-induced SER's than NISES. On the other hand, NISES covers more applications; it simulates neutron-induced charge collection, multiple-bit SE, and [alpha]-induced SE analysis.
The authors review two types of simulators for the analysis of cosmic ray neutron-induced soft errors (SE's). One of them is the neutron-induced soft error simulator (NISES). A recently proposed nuclear reaction theory forms the foundation for the nuclear reaction database used in NISES. The other simulator, the simplified simulator MBGR, is based on a modified version of the burst generation rate (BGR) model. Both simulators accurately simulate neutron-induced SE rates (SER's). MBGR actually provides an easier and quicker estimation of neutron-induced SER's than NISES. On the other hand, NISES covers more applications; it simulates neutron-induced charge collection, multiple-bit SE, and #alpha#-induced SE analysis
One of the significant factors of neutron radiographic image degradation is scattering blur from the object. A practical method is described to enhance image quality by eliminating the overlapping of scattered thermal neutrons component from the objects in ETRR-2 neutron radiography facility, using aluminum Gd-coated antiscatter grid. The MCNP code was used to determine the optimum grid dimensions that will reduce the scattered thermal neutrons from the object. An experiment was performed to determine the optimum grid height and irradiation time that gives the best image with acceptable geometric unsharpness. Using the MCNP code it was found that 97% of the scattered neutrons were removed by the grid. The wall dimensions and Gd coating are so small that the facility resolution cannot detect the image pattern superposition on the film.
For neutron radiography (NR), photographic techniques have been mainly used for many years. To observe a dynamic event and to test many samples, the real-time neutron radiography (i.e. neutron television - NTV) system has been introduced at the E-2 experimental tube of the Kyoto University Research Reactor (KUR). The NTV system has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuel, to investigation of moving objects and to neutron computed tomography (NCT). New approaches using some advanced neutron converters, a high sensitive and resolution TV camera and a high performance image processing system are being undertaken for standard indicators, visualization on air-water two-phase flow, NCT and so on. (author).
Japan Atomic Energy Research Institute (JAERI) is developing the world`s strongest spallation neutron source using high power proton accelerator and promoting a neutron science project for comprehensive studies on basic science and nuclear transmutation of high-level radioactive nuclide from nuclear power stations. For this purpose, JAERI organized the Special Taskforce for Neutron Science and OMEGA Project in April 1996 and reorganized it to Center for Neutron Science in April 1997. During this period, various research plans using the spallation neutron source are proposed and facilities necessary for research are studied by mainly research groups of JAERI. This report describes research plans and results of the preliminary conceptual design study on proposed facilities plan. (author)
Neutron energy spectra were measured for two OSURR experimental facilities. The method of multiple foil activation was used with the SAND-II neutron spectrum unfolding code to obtain spectral data for the Central Irradiation Facility and Rabbit tube. Limited data was obtained for the thermal column using only gold foils. Calculations were made of the neutron environment in various locations using the MORSE code. A shift towards higher neutron energies was observed comparing results for LEU and HEU cores. A slight loss in total thermal neutron flux was measured for all positions. Calculational results show reasonable agreement with measured data.
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed at the University of Texas TRIGA reactor. Extensive Monte Carlo design calculations were used to determine optimal design parameters of the neutron collimator system to avoid costly trial and error. Thermal neutron flux determined by gold foil activation is 5 {times} 10{sup 6} n/cm{sup 2}{center_dot}s at the primary imaging location with beam size of 22.5 cm in diameter. The collimation ratio can be varied from 125 to 235. The neutron-to-gamma ratio is 7.8 {times} 10{sup 6} n/cm{sup 2}{center_dot}mR. The facility has been tested for radiography and tomography applications and is now fully operational.
A neutron scanning device was developed in order to obtain accurate neutron intensities of high burn-up BWR fuels. This scanning device was calibrated with a "2"5"2Cf source and used to measure axial distributions of neutron intensities of BWR fuels with various enrichments (2.0%-3.4%) irradiated up to 60 GWd/tU at Fukushima Daini Nuclear Power Station Unit 2(2F-2). The measured neutron intensities were approximated well with power law interpolations on the calculated burn-up values. The neutron intensities calculated by the ORIGEN2-86 code showed good agreements with the measured ones within 20%. (author)
Measurements of neutron and gamma-ray penetrations in an iron shield were performed up to a 60-cm depth in a tightly coupled source shield configuration with the fast-neutron reactor YAYOI as a source. Rates of neutron reactions and gamma-ray dose rates in the iron shield were obtained using activation foils and thermoluminescent dosimeters. Analyses of the experiments were made by using the DOT-III code with coupled neutron and gamma-ray cross sections from ENDF/B-IV and POPOP4 libraries. To obtain the source condition for the iron shield analyses, the calculated spectrum was adjusted to the measured reaction rates at the reactor shield boundary. The calculated neutron and gamma-ray distributions in the iron shield show fairly good agreement with the experiments. The effect of difference in Bondarenko-type self-shielding factors on the analyses of the iron shield is also shown.
A successful boron neutron capture treatment (BNCT) of a patient with multiple liver metastases has been first given in Italy, by placing the removed organ into the thermal neutron column of the Triga research reactor of the University of Pavia. In Finland, FiR 1 Triga reactor with an epithermal neutron beam well suited for BNCT has been extensively used to irradiate patients with brain tumors such as glioblastoma and recently also head and neck tumors. In this work we have studied by MCNP Monte Carlo simulations, whether it would be beneficial to treat an isolated liver with epithermal neutrons instead of thermal ones. The results show, that the epithermal field penetrates deeper into the liver and creates a build-up distribution of the boron dose. Our results strongly encourage further studying of irradiation arrangement of an isolated liver with epithermal neutron fields.
The effects of group structures and weighting functions on neutron penetration through a thick Na-Fe geometry are studied. The recommended broad-group (61-neutron/23-gamma-ray) and few-group (22-neutron/10-gamma-ray) structures are tailored to the sodium and iron resonances, windows, and capture gamma-ray spectra. The best weighting functions are shown to be fine-group fluxes selected from a few key locations in the geometry. These group structures and weighting functions, relative to existing group structures and conventional weighting functions, improve the accuracy of the computed 61-neutron-group Bonner ball responses by up to one hundred percent and of the computed 22-neutron-group results by up to six hundred percent.
An apparatus for non-invasively inspecting an object, such as an item of luggage, for explosives material is described. It comprises a multi-channel thermal neutron inspection system having a plurality of neutron irradiation chambers. Simultaneous operation of several channels increases the maximum system throughput several times. Each chamber has a lithium neutron source which is stimulated to neutron production by a proton beam. Beam switching magnets are energised by pulsing to divert a common proton beam to each source in turn. The initial beam is generated by a radio frequency quadrupole accelerator. The advantages of this system are very low residual source activity and controllable neutron production thereby minimising safety hazards. The irradiation chamber may contain several different gamma ray detectors to identify the elements present in explosives material. In addition, ...
Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological ...
A new methane cold neutron source has been tested at the IBR-2 pulsed reactor at the Frank Laboratory of Neutron Physics. In a paper the results of experiments at neutron diffractometers HRFD and DN-2 which are placed at the IBR-2 from the methane moderator side are given. A comparison with the results obtained with the conventional water comb-like moderator is performed. The perspectives of the cold source for various kinds of neutron diffraction experiments, including atomic and magnetic structural analysis and real time experiments are discussed. It is shown, that for a huge number of the experiments which are performing at both HRFD and DN-2 the methane cold neutron source provides the better conditions than water comb-like moderator.
The coupled neutron-gamma cross section libraries BUGLE-80 and SAILOR are compared, with focus on gamma production and transport and its sensitivity to the thermal component of the neutron flux. In addition, the importance of the prompt versus delayed components of the gamma source is addressed. Although BUGLE-80 shows some discrepancies in the core region, the two libraries demonstrate similar capability in the vicinity of the pressure vessel and beyond. The delayed fission product gammas from the core have little impact on the local gamma fluxes beyond the pressure vessel. Although thermal neutron capture is the dominant component of the gamma source, there is little sensitivity of the gamma source to uncertainties in the thermal neutron cross sections, due to compensating effects which tend to keep the thermal neutron capture rate relatively constant.
Abstract - We have designed, built, and tested a 2-D pixellated thermal neutron detector. The detector is modeled after the MicroMegas-type structure previously published for collider-type experiments. The detector consists of a 4X4 square array of 1 cm 2 pixels each of which is connected to an individual preamplifier-shaper-data acquisition system. The neutron converter is a 10B film on an aluminum substrate. We describe the construction of the detector and the test results utilizing 252Cf sources in Lucite to thermalize the neutrons.Drift electrode (Aluminum) Converter (10B) 3 mm Conversion gap neutron (-900 V)
Mechanical properties, flow characteristics and chemical resistance of polycarbonate (PC)/polybutylene terephthalate (PBT)/impact modifier (IM) blends were investigated over the various composition ranges of PC and PBT. Mechanical properties of the PC/PBT/IM blends for different IMs, butadiene based IM and butyl acrylate based IM, were studies for various compositions of the IMs. Impact strength at low temperature was also observed. For the study of chemical resistance of the PC/PBT/IM blends, the blends were dipped in organic solvent, thinner, and then variations of mechanical properties were analyzed. Tensile and flexural strengths were increased linearly and heat distortion temperature (HDT) also increased as PC content in the blends increased. Impact strength increased drastically as PC content increased up to 50 wt% and stayed stable value. Flowability decreased as PC content increased. impact ...
High precision fundamental neutron physics experiments have been proposed for the intense pulsed spallation neutron beams at JSNS, LANSCE, and SNS to test the standard model and search for new physics. Certain systematic effects in some of these experiments have to be controlled at the few ppb level. The NPD Gamma experiment, a search for the small parity-violating {gamma}-ray asymmetry A{sub Y} in polarized cold neutron capture on parahydrogen, is one example. For the NPD Gamma experiment we developed a radio-frequency resonant spin rotator to reverse the neutron polarization in a 9.5 cm x 9.5 cm pulsed cold neutron beam with high efficiency over a broad cold neutron energy range. The effect of the spin reversal by the rotator on the neutron beam phase space is compared qualitatively to rf neutron spin flippers based on ...
The principal mathematical tools frequently available for calculations in Nuclear Engineering, including coupled neutron-gamma radiations shielding problems, involve the full Transport Theory or the Monte Carlo techniques. The Multigroup Albedo Method applied to shieldings is characterized by following the radiations through distinct layers of materials, allowing the determination of the neutron and gamma fractions reflected from, transmitted through and absorbed in the irradiated media when a neutronic stream hits the first layer of material, independently of flux calculations. Then, the method is a complementary tool of great didactic value due to its clarity and simplicity in solving neutron and/or gamma shielding problems. The outstanding results achieved in previous works motivated the elaboration and the development of this study that is presented in this dissertation. The radiation balance ...
Boron Neutron Capture Therapy (BNCT) is a promising binary treatment modality for high-grade primary brain tumors (glioblastoma multiforme, GM) and other cancers. BNCT employs a boron-10 containing compound that preferentially accumulates in the cancer cells in the brain. Upon neutron capture by {sup 10}B energetic alpha particles and triton released at the absorption site kill the cancer cell. In order to gain penetration depth in the brain Fairchild proposed, for this purpose, the use of energetic epithermal neutrons at about 10 keV. Phase I/II clinical trials of BNCT for GM are underway at the Brookhaven Medical Research Reactor (BMRR) and at the MIT Reactor, using these nuclear reactors as the source for epithermal neutrons. In light of the limitations of new reactor installations, e.g. cost, safety and licensing, and limited capability for modulating the reactor based neutron ...
The Neutron Radiography Reactor (NRAD) operated by Argonne National Laboratory is described in this paper. NRAD was designed to allow radiography of highly absorbing reactor fuel assemblies in the vertical position on the routine basis. 7 figs.
Revised neutron fluence and damage values are reported for the MOTA-2A experiment in the Fast Flux Test Facility (FFTF). This revision corrects an error with processing of the {sup 235}U(n,f) reaction. Net corrections are on the order of 5%.
An array of multiwire proportional counters has been employed to image, in 'real-time', a collimated neutron beam produced at an electron linac facility. Test results are presented, along with a discussion of the advantages of this technique.
This neutron reflectometry study evaluates the structures resulting from different methods of preparing polymer-cushioned lipid bilayers. Four different techniques to deposit a dimyristoylphosphatidylcholine...Full Text Available
The observation by inelastic neutron scattering techniques of a high energy peak in the phonon spectrum (14 THz) of V_3Si is reported, and is attributed to a peak in the phonon density of states due to vanadium motions by the incoherent inelastic neutron scattering process.
We argue that neutron interference experiments and experiments on gravitational bound states of neutron unambiguously disprove entropic origin of gravitation. The criticism expressed in a recent paper [arXiv:1104.4650] concerning our arguments against entropic gravity is shown to be invalid.
The 1985 evaluation of A = 1-1 (85B1114) has been revised. Experimental information is presented from the neutron-rich {sup 101}Sr to the neutron-deficient {sup 101}In.
The 1985 evaluation of A = 1-1 (85B1114) has been revised. Experimental information is presented from the neutron-rich "1"0"1Sr to the neutron-deficient "1"0"1In.
A study of the joint evolution of the normal- and neutron-star components of massive binaries opens with a classification scheme and the analytic expressions to be applied in Paper II for computer simulation of the observable properties of such systems.
Neutron Star Evolution with Internal Energy h'q/>a. Dissipation by Vortex Creep. N. Shibazaki and F. K. Lamb. University of Illinois at Urbana-Champaign ...
The availability of new, high-intensity, cold and thermal neutron sources has opened the possibility of performing high-precision fundamental neutron physics experiments, including measurements that study the hadronic weak interaction and standard model test measurements, using neutron decay. The observables in these experiments are usually correlated with the direction of neutron polarization and are often very small (10 8 10 6). Mott-Schwinger scattering of polarized neutrons can produce spin-dependent shifts in beam centroids, which has the potential to produce significant systematic effects for these types of experiments. An accurate calculation of this process for neutral atoms and basic molecules has not been carried out for low neutron energies. In this work, we derive a general expression for the electromagnetic (Mott-Schwinger) contributions to the ...
We present the results of modeling intended to evaluate the feasibility of using neutrons from induced fission in highly enriched uranium (HEU) as a means of detecting clandestine HEU, even when it is embedded in absorbing surroundings, such as commercial cargo. We characterized radiation from induced fission in HEU, which consisted of delayed neutrons at all energies and prompt neutrons at energies above a threshold. We found that for the candidate detector and for the conditions we considered, a distinctive HEU signature should be detectable, given sufficient detector size, and should be robust over a range of cargo content. In the modeled scenario, an intense neutron source was used to induce fissions in a spherical shell of HEU. To absorb, scatter, and moderate the neutrons, we place one layer of simulated cargo between the source and target and an identical layer between the ...
The cosmic ray neutron spectrum at sea level has been measured by the method of pulse shape discrimination in anthracene scintillator. The exponent of the differential spectrum was found to be 2.2+-0.1. (Auth.).
An analytic model of magnetic torques applied to an accreting neutron star is employed to evaluate the magnetic dipole moments of x-ray pulsars. A new type of close binary system containing a neutron star is suggested.
A technique was developed that permits fluid flow to be visualized even where the flow is completely shrouded by metal. The technique employs real-time neutron radiography, which is similar to x-ray radiography except a collimated beam of neutrons is used. Various combinations of neutron-opaque tracer materials were tested with neutron-transparent fluid. Neutron opaque tracers, such as solid particles, fluid droplets, and streaklines were imaged through metal walls as they convected in neutron-transparent ambient fluid. Visualization of bubbles/voids were evaluated for possible future applications. Surface-flow patterns were also imaged by using neutron-opaque tufts. These techniques were evaluated for image contrast, resolution, and the ability to accurately track fluid flow fields. The techniques were also modeled to optimize contrast in ...
A prototype detector based on the inclined boron layer principle is introduced. For typical measurement conditions at the Liquids Reflectometer at the Spallation Neutron Source, its count rate capability is shown to be superior to that of the current detector by nearly two orders of magnitude.
A prototype detector based on the inclined absorber layer principle is introduced. For the Liquids Reflectometer at the Spallation Neutron Source, it is shown to be a significant improvement over its current detector, which imposes an instantaneous count rate limitation of 50 kcps.
Main features of star evolution are recalled. Then the general structure of white dwarf stars is examined. From the equation of state of an electron gas completely degenerated are deduced: mechanical equilibrium, Viriel theorem, mass-radius relationship and Chandrasekhar limit. These results are applied to neutron stars.
The personal neutron dosimetry becomes more important with the increasing use of nuclear and accelerator facilities. The solid state track detector, film badge and thermo-luminescent dosimeter have widely been used as passive-type personal neutron dosimeters, but the real-time neutron dosimeter is strongly needed. A real time personal dosimeter which could give neutron dose equivalent over wide energy range from thermal to 10 odd MeV by using two neutron sensors has been developed by our group. For practical commercial product, some changes from these prototype sensors have recently been done by Fuji Electric Co. Ltd. The purpose of this work is the final performance test of the dosimeter just before sale. We checked again about the sensitivity in the monoenergetic neutron field from 8 keV to 15 MeV and in the neutron fields around a few ...
Careful measurements do not confirm an anomalous anisotropy in the angular distribution of fission fragments from the fast neutron fission of Americium 242. The energy range covered was 1.60-3.15 MeV. (AIP)
An array of multiwire proportional counters has been employed to image, in 'real-time', a collimated neutron beam produced at an electron linac facility. Test results are presented, along with a discussion of the advantages of this technique. (orig.).
The usual method of introducing engineers to the concept of dislocations and their role in plastic flow is to compare an estimate of the theoretical strength of solid (of order {micro}/30 where {micro} is the shear modulus) and the observed strength of either single crystals ({mu}/10{sup 4}) or practical engineering material such as structural steels where the yield stress in shear is of order {mu}/10{sup 3}. However, if one considers the problem in reverse, one can consider the accumulation of dislocations as an important mechanism by which one can produce engineering materials in which the strength level approaches the theoretical strength. If one assumes that the flow stress can be expressed in terms of te mean free path between stored dislocations or as the square root of the global dislocation density, then one can see the influence of dislocation density in a diagrammatic form. It is clear that ...
Phase transformations in TiD_#approx#_0_._7_5 subjected to high-pressure treatment were investigated by simultaneous real-time measurements of neutron diffraction and small-angle neutron scattering. The neutron spectra were taken on heating the samples in temperature ranges 100 to 300 K and 300 to 870 K. A sequence of structural transitions was observed, which involves 7 different phases and intermediate states with hcp, fcc, fco or bcc metal sublattices and hydrogen atoms. 30 refs., 9 figs., 1 tab.
We report on measurements of radiation hardness of the plastic scintillating fiber SCSF-81. Fibers were irradiated with "6"0Co #gamma#-rays and fast neutrons up to 105 Gy and up to 5 x 1013 n/cm"2, respectively. Deterioration of the attenuation length of the scintillating fiber was studied. Some significant deterioration was observed at the integrated dose of about 1 x 103 Gy and at the integrated neutron flux (neutron fluence) of about 1 x 1012 n/cm"2 for #gamma#-ray and neutron irradiation, respectively. (author).
An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.
An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.
The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q{sup 2}=1.0-4.8 GeV{sup 2} with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.
The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q2=1.0-4.8 GeV2 with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.
Neutron resonance interactions with /sup 100/Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% /sup 100/Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture ..gamma..-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.
Reliable facility of cyclotron-based real time neutron radiography system has been developed and applied to some industrial components. The equipment for neutron fluoroscopy is based on a sub-compact cyclotron and a LiF/ZnS (Ag) fluorescent screen viewed by a silicon intensifier target TV camera. The real time image is monitored on a CRT, recorded with a standard video recorder and processed by a digital image processor. The effectiveness of our real time neutron radiograph has been demonstrated to be applicable to not only the dynamic observation but also the magnifying and stereoscopic observation of fluoroscopic images. (author).
Fission reaction rates for four nuclides were measured in the leakage spectrum outside spherical water moderators of various radii surrounding a {sup 252}Cf neutron source. Using the MCNP transport code, matching calculations were made with highly detailed modeling of the measurement apparatus. The calculations predicted significantly higher leakage of neutrons in the epicadmium energy range than was found in the measurements. A discrepancy of the same sign but weaker magnitude was found for thermal neutrons. These discrepancies may be relevant to problems with criticality calculations in special cases.
Energy conservation and local energy deposition are investigated in the context of coupled-particle (i.e., neutrons, gamma rays, and charged particles) transport analysis. For charged particles, the concept of group splitting the 1 = 0 transfer matrix to ensure both particle and energy conservation is introduced. Although these procedures are more complex than those found in the usual neutron or coupled-neutron gamma-ray problem, they yield a consistent approach for the calculation of local energy deposition.
Energy conservation and local energy deposition are investigated in the context of coupled-particle (i.e., neutrons, gamma rays, and charged particles) transport analysis. For charged particles, the concept of group splitting the 1 = 0 transfer matrix to ensure both particle and energy conservation is introduced. Although these procedures are more complex than those found in the usual neutron or coupled-neutron gamma-ray problem, they yield a consistent approach for the calculation of local energy deposition.
Abstract. The modification of kaon and antikaon properties in the interior of (proto-)neutron stars is investigated using a chiral SU(3) model. The parameters of the model are fitted to nuclear-matter saturation properties, baryon octet vacuum masses, hyperon optical potentials and low-energy kaon-nucleon scattering lengths. We study the kaon/antikaon medium modification and explore the possibility of antikaon condensation in (proto-)neutron star matter at zero as well as finite temperature/entropy and neutrino content. The effect of hyperons on kaon and antikaon optical potentials is also investigated at different stages of the neutron star evolution.
The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)
This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.
This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.
The spherical harmonic analysis of cosmic ray neutron data from the worldwide network neutron monitor stations during the years 1966 to 1969 was carried out. The second zonal harmonic component obtained from the analysis corresponds to the Pole-Equator anisotropy of the cosmic ray neutron intensity. Such an anisotropy makes a semiannual variation. In addition to this, it is shown that the Pole-Equator anisotropy makes a variation depending on the interplanetary magnetic field (IMF) sector polarities around the passages of the IMF sector boundary. A mechanism to interpret these results is also discussed.
We made Basic designs of neutron guide, choppers, and detectors in order to optimize the design parameters of DC-TOF to be built in the HANARO Cold Neutron Guide Hall. In addition, we calculated the expected performance of DC-TOF using Monte Carlo simulations and evaluated the properties of neutron beam. Based on the results we obtained, we have compared the expected performance of the DC-TOF with those of existing instruments overseas. In conclusion, we believe that we will be able to construct the DC-TOF at HANARO as one of the best instruments of its kinds and it will become an invaluable instrument to researchers in the related field.
Instrumental neutron activation analysis is used for simultaneously determination of macrocomponents in ferroelectric materials LLZT. Pb, Zr, Ti have been determined by "2"0"3Pb, "8"9Zr and "4"8Sc nuclides created by fast neutron (14.5 MeV) activation. Application of paraffine as neutron moderator and reflector allows to simultaneously determine lanthanum by "1"4"0La nuclide. It has been shown that zirconium, titanium and lanthanum can be determined with the accuracy of #+-#0.1 mas. % and lead - #+-#0.7 mas. %.
We have developed a new type personal dosemeter by using a B-10 doped silicon p-n junction detector with a polyethylene radiator and a polyethylene moderator. The purpose of this study was to develop a real time neutron dosemeter with a nearly flat response in the energy range from thermal to 15 MeV and low angular dependence to the incident neutron direction. The neutron response of the dosemeter was obtained with the Monte Carlo calculation and the monoenergetic neutron experiment in a free air field and also under a condition attached on a phantom.
A powder neutron diffraction study has been carried out on /sup 239/PuN, which was reported to be antiferromagnetic below T = 13 K. No magnetic ordering has been detected at 4 K, the limit of the magnetic ordering which could be detected being ..mu..sub(ord) = 0.25 ..mu..sub(B) per Pu atom. Moreover a neutron scattering length determination of /sup 239/Pu was performed which gave a value of bsub(239Pu) = (0.81 +- 0.05) x 10/sup -12/ cm at a neutron wavelength lambda = 1.219 A.
The mixed structure of a nuclear reactor building is composed of SC-columns, S-beams, S-joints and PCa-panels. Following the last report (Part 7)[1], the main test results of the mixed structure, that is, the deformation mode, strain distribution and shear strength, are described. The S-joints using ultrahigh strength materials had no buckling nor shear slipping. The proposed mixed structure resisted the external horizontal forces under integrated uniformity among SC-columns, S-joints and PCa-panels. It could be confirmed that the mixed structure can be established. (author)
Extrusion and subsequent heat treatment of the alloys investigated can lead to reasonable room temperature ductilities and very high strengths being developed compared to the cast + HlPed material. In Ti-45Al-10Nb reasonably room temperature fracture toughness was developed which did not depend on extrusion temperature. For the alloy Ti-48Al-2Cr-0.2C a previously developed solution and ageing heat treatment did not increase the high temperature strength properties when compared to the 'annealed' condition. (orig.)
There is proposed the nonlinear model of dose dependence saturation of the yield strength on the base of the vacancy and interstitial barrier interaction in this work. Processes of mutual recombination of vacancy and interstitial barriers and formation of vacancy and interstitial clusters are taken into consideration. In the framework of the model, the analytical equations corresponding to the evolution of the barrier densities and yield strength are obtained. It is shown that the yield strength of irradiated materials decreases with the increasing intensity of barrier recombination processes, the dependence being nonlinear. Also it is shown that the model is valid both for low doses and large doses on the stage of radiation hardening.
Studied are the mechanical properties of welded joints and heat affected zones of the Kh8N10T steel and OT4 and VT1-2 titanium alloys on welding in Ar+deltaF_6 and Ar+CCl_2F_2 mixtures contributed to a decrease of porosity. Tensile and impact tests of welded joints have revealed that additions of sulfur hexafluoride into argon causes a decrease of impact strength in titanium alloy when the tensile strength does not depend on the composition of a halogen-containing atmosphere. Freon (CCl_2F_2) additions decrease only slightly the impact strength of the investigated alloys.
An accelerator has limited dynamic range: a chain of accelerators is required to reach high energy. A combination of septa and kicker magnets is frequently used to inject and extract beam from each stage. The kicker magnets typically produce rectangular field pulses with fast rise- and/or fall-times, however the field strength is relatively low. To compensate for their relatively low field strength, the kicker magnets are generally combined with electromagnetic septa. The septa provide relatively strong field strength but are either DC or slow pulsed. This paper discusses injection and extraction systems with particular emphasis on the hardware required for the septa.
An oil-immersion electrically insulated cable of high performance is constructed by wrapping a conductor with an insulating layer formed by winding on the conductor polypropylene film, and impregnating the insulating layer with an insulating oil preferably dodecyl benzene. The polypropylene film has a density in the range of 0.905 to 0.915 g/cm/sup 3/, birefringence in the range of 0.020 to 0.035, ratio of strengths in two axial directions (tensile strength in the longitudinal direction/tensile strength in the lateral direction) in the range of 5 to 15, and thickness in the range of 70 to 300 microns.
The effect of additives on the grafting of a monomer, butylmethacrylate (BA), into simul (a soft wood) has been studied using {sup 60}Co source at 3 Mrad. The enhancement of polymer loading (grafting) by the addition of minute amounts (1%) of oligomers and of polyfunctional monomers into simul + BA system has been further increased in the presence of acid and urea. The synergistic polymer loading yields by acid addition cause substantial decrease of tensile strength values of wood-plastic composite; but urea increases both polymer loading and tensile strength values synergistically in these systems. (author).
The effect of additives on the grafting of a monomer, butylmethacrylate (BA), into simul (a soft wood) has been studied using "6"0Co source at 3 Mrad. The enhancement of polymer loading (grafting) by the addition of minute amounts (1%) of oligomers and of polyfunctional monomers into simul + BA system has been further increased in the presence of acid and urea. The synergistic polymer loading yields by acid addition cause substantial decrease of tensile strength values of wood-plastic composite; but urea increases both polymer loading and tensile strength values synergistically in these systems. (author).
The compressive and bending strengths of a local tropical wood (Kapur-Dryobalanop sp.) were improved significantly by suitable impregnation of polymeric monomers (methylmethacrylate, methylmethacrylate - 5% dioxane and vinyl acetate) into the wood cellular structure and subsequent irradiation to form a wood-polymer composite. Statistical analysis revealed a linear relationship between increase in the strengths and the percentage of polymer impregnated. Fractographic analysis of the impact fractured surfaces under the scanning electron microscope showed the nature of the wood-polymer interface, which could account for the increase in the compressive and bending strengths. (author).
ObjectivesObjectives Not AvailableDescriptionTo determine the effects of water penetration on the burst strength of filament wound composite pipes which have been damaged by impact and then subjected to long term pressurisation with sea water. ~%~ To monitor and characterise the damage and effects of sea water penetration using ultrasonic NDT. To determine the burst strength of bonded composite pipe joints with and without defects and to see whether the defects can be detected using ultrasonic NDT. [continued...
A variety of advanced controlled rolling techniques have been developed to improve toughness, strength and weldability of niobium-steels. To achieve optimum properties, control of prior stage rolling conditions and accelerated cooling are needed. In low carbon steel, the addition of niobium results in a greater increase in tensile strength than that of vanadium without a loss of toughness. At the same strength level, niobium-steel has less susceptibility to weld cracking and good toughness in the HAZ of its weldments than similar vanadium steels. Separation and formability of niobium steels are also discussed.
In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).
In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).
Using the Relativistic Mean Field Theory (RMF) it is shown that different proton fraction which is directly connected with the neutron excess and with the asymmetry of the system affects proto-neutron stars parameters and changes their composition. The obtained form of the equation of state allows to construct the mass-radius relations and shows that the increasing asymmetry creates more compact stars. The inclusion of {delta} meson together with nonlinear vector meson interaction terms and magnetic field make this effect even stronger.
The current status and future plans of the Ok Ridge Spallation Neutron Source (ORSNS) are reviewed. The ORSNS is a new project initiated by the U.S. Department of Energy (DOE) beginning October 1, 1995, to prepare the conceptual for a new spallation neutron source. (author) 2 refs.
The status of neutron activation cross sections for some threshold reactions important for reactor materials dosimetry is reviewed. An attempt is made to understand and explain discrepancies between integral and differential data, using recent available experimental results. The importance of standard and benchmark neutron fields for testing differential data for reactor dosimetry is emphasized and the Interlaboratory Reaction Rate (ILRR) program, as well as a similar program pursued by the IAEA, are briefly described.
The energy distribution of neutrons generated due to bombardment of 40 MeV alpha particles on thick elemental tantalum is measured using threshold activation detectors. A method of unfolding the neutron spectrum from the activation data based on information-entropy weighted average solution is described. The present unfolding method does not require 'a priori' information about the shape of the solution spectrum. 16 refs. (author).
Structural units of a hydrogen fuel cell whose characteristics are advisable to investigate by different neutron scattering methods are discussed. The results obtained with the use of Bragg diffraction and small-angle neutron scattering from fuel membranes, nanocarbon-platinum catalysts, and Zn_1_-_xCu_xO hydrogen storage systems are presented.
The structural variations of amorphous metals, such as Pd/sub 80/Si/sub 20/, with irradiation of helium ion, neutron, and gamma ray have been mainly pursued by the method of X-ray diffraction and thermal analysis. It should be noticed that the amorphous metals show a radiation resistance, that is, no remarkable structural changes under helium ion, neutron, and gamma ray irradiation.
Recent nucleosynthesis calculations of Type II supernovae using advanced neutrino transport determine that the early neutrino winds are proton-rich. However, a fraction of the ejecta emitted at the same time is composed of neutron-rich pockets. In this paper we calculate the nucleosynthesis contribution from the neutron-rich pockets in the hot convective bubbles of a core-collapse supernova and show that they do not contribute significantly to the total nucleosynthesis.
This meeting focussed on the study of the structure and dynamics of biological molecules, with particular emphasis on neutron and complementary methods as well as related enabling technologies. The program covered biological problems that are being addressed by neutron scattering and those where there is the potential to do so in the future. This document provides the abstracts of the different presentations. (A.L.B.)
The image processing system for the dynamic neutron radiography has been developed. It is based on the hardware subset, composed by the method of the pipe-line and use of algorithm of local statistics. The processing speed per one pixel is shorter than 100 n sec and video-rate processing can be executed on it. Some image processes for improving the quality of the real-time neutron image, noise reduction and contrast stretching would be attempted by the use of this system. (author).
The importance of neutron measurements both as a succinct measure of the progress to fusion ignition using the magnetic confinement route and also as a diagnostic of plasma conditions is discussed. The various neutron diagnostic systems that have been or are being constructed by AERE Harwell for JET are described. The properties to be measured by such diagnostics are clearly identified and some results obtained with the installed diagnostics during d-d plasmas are presented.
ORNL has developed the technology to detect hidden explosives in luggage using X ray and neutron detection devices. The Federal Aviation Administration has ordered the airlines to buy and install Thermal Neutron Analysis (TNA) units. The combined pulsed-neutron and X-ray interrogation inspection (CPNX) system developed at ORNL uses less radioactive materials as well as being more sensitive to weapons, electronic devices and plastic explosives.
The gamma-ray spectrum following neutron capture on /sup 87/Sr was measured at 3 neutron energies: E/sub n/ = thermal, 2 keV, and 24 keV. Gamma rays were detected in a three-crystal Ge(Li)-NaI-NaI pair spectrometer. Gamma-ray intensities deduced from these spectra by spectral unfolding are presented.
A facility for studying photon-neutron reactions under a braking #gamma#-beam with an energy of up to 26 MeV from a betratron includes Saratov-2, SM-4A, and IBM AT-386 microcomputers. Neutron detectors, pulsed braking radiation dosimeters, and the devices to control the betatron energy are described.
In this study the development of a methodology to detect illicit drugs and plastic explosives is described with the objective of being applied in the realm of public security. For this end, non-destructive assay with neutrons was used and the technique applied was the real time neutron radiography together with computerized tomography. The system is endowed with automatic responses based upon the application of an artificial intelligence technique. In previous tests using real samples, the system proved capable of identifying 97% of the inspected materials.
The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)
The principal mathematical tools frequently available for calculations in Nuclear Engineering, including coupled neutron-gamma radiations shielding problems, involve the full Transport Theory or the Monte Carlo techniques. The Multigroup Albedo Method applied to shieldings is characterized by following the radiations through distinct layers of materials, allowing the determination of the neutron and gamma fractions reflected from, transmitted through and absorbed in the irradiated media when a neutronic stream hits the first layer of material, independently of flux calculations. Then, the method is a complementary tool of great didactic value due to its clarity and simplicity in solving neutron and/or gamma shielding problems. The outstanding results achieved in previous works motivated the elaboration and the development of this study that is presented in this dissertation. The radiation balance ...
Systems MEMS sensors C11-20 Lifetime Distributions of Aluminum Electrolytic Capacitors C11-22 Adhesion Strength of Advanced Polymer Films for Flexible and Rigid...
SUMMARYHomeostatic synaptic plasticity is a negative feedback mechanism neurons use to offset excessive excitation or inhibition by adjusting their synaptic strengths. Recent...Full Text Available
The diffusion coefficients (De) in bentonite were measured to understand and quantify the influence of groundwater chemistry such as ionic strength and to quantify the alteration of smectite mineralogical transformations. (author)
The effect of W and V on the high temperature strength properties of 12%Cr-15%Mn austenitic steels was studied from the view point of precipitation hardening and internal stress. The contribution of W addition to the tensile and creep-rupture strength was not so large. By contrast the combined addition of W and V increased the strength considerably. These are resulted from the precipitation of fine vanadium nitride (VN) within grains and the enhancement of M_2_3C_6 type carbide precipitation at grain boundaries. The V added material had large internal stress value which is considered to be due to dislocation movement disturbed by fine vanadium nitrides. (author).
... by the boron doping in most of the alloys except for Al66Mn9Zr25 + 50 ppm B alloy; permanent deformation at ultimate compressive strength is not ...
Objective.The objective of this study was to use the newly synthesized poly(quaternary ammonium salt) (PQAS)-containing polyacid to formulate the light-curable glass-ionomer cements and study the effect of the PQAS on the compressive strength and antibacterial activity of the formed cements.Materials and methods.The functional QAS and their constructed PQAS were synthesized, characterized and formulated into the experimental high-strength cements. Compressive strength (CS) and Streptococcus mutans viability were used to evaluate the mechanical strength and antibacterial activity of the cements. Fuji II LC cement was used as control. The specimens were conditioned in distilled water at 37 degrees C for 24 h prior to testing. The effects of the substitute chain length, loading as well as gra...
Composite Sandwich Panels under Different Thermal Environments, Composite Structures, Vol. 25,. July 1993, pp. 227239. 11. Ko, William L., Mechanical and ...
BackgroundPrior research links optimism to physical health, but the strength of the association has not been systematically evaluated.PurposeFull Text Available
... More particularly, the invention relates to novel felted combustible cartridge cases of excellent tensile strength, water resistance and combustibility. ...
Watkins,. Charles. E. : Effect of Aspect. Ratio on the Air ...... Grover,. H. 3. ; Bishop,. S. M. ; and. Jackson,. L. R. : Fatigue. Strengths of Aircraft ...
An assessment of the joint shear strength of exterior concrete beam-column joints reinforced internally with Glass Fibre Reinforced Polymer (GFRP) reinforcements under monotonically increasing load on beams keeping constant load on columns is carried out in this study. Totally eighteen numbers of specimens are cast and tested for different parametric conditions like beam longitudinal reinforcement ratio, concrete strength, column reinforcement ratio, joint aspect ratio and influence of the joint stirrups at the joint. Also finite element analysis is performed to simulate the behaviour of the beam-column joints under various parametric conditions. Based on this study, a modified design equation is proposed for assessing the joint shear strength of the GFRP reinforced beam-column specimens b...
Four commercial stainless steels (mat. Nos. 1.4539, 1.4586, 1.4571 and 1.4462) were tested in 96% and 90% sulfuric acid of 80/sup 0/C as to their corrosion fatigue strength by subjecting notched round bars to the rotary bending test. At the same time, the efficiency of anodic protection was examined. With all four steels, the alternating bending strength obtained in the air is essentially reduced. The semiaustenitic steel Nr. 1.4462 shows a lower corrosion fatigue strength than the three austenitic steels. Although making the corrosion fatigue strength of steels better calculable, anodic protection proves insufficient to completely prevent notched round bars from corrosion fatigue in concentrated sulfuric acid.
Ultimate Compressive Strength of Short Sheet - Stringer Panels With Special. Reference to the Influence of the Riveted Connection Between Sheet and Stringer ...
In the feasibility study on commercialized FBR systems, the application of 12Cr steel, with its physical properties and high-temperature strength properties, as structural material is considered in order to greatly reduce construction costs by compacted instruments and structures. In this report, creep, fatigue and the creep-fatigue properties of Mod.9Cr-1Mo steel forging (thickness 550mm) weld, representing conventional steels, were evaluated in order to obtain the needed basic data for the evaluation of the high-temperature strength of 12Cr steel weld. The results obtained are as follows: (1) Metal suitable for HAZ was made by applying thermal treatment to simulate the thermal hysteresis during welding to clearly define creep and fatigue properties in a HAZ softened zone. (2) Creep strength of the weld metal and the welded joint was equal to that of the base metal. However, the welded joint ruptured in the HAZ softened ...
hlgh fiber content composites met the minlmum requirements. (1400 O F ) , the hlgher fiber content as-fabricated composites have impact strengths distinctly ...
... Wright, and Vogel, 1985; Patton, Vogel, Damo- shorter amount of time at the end of the 45-hour kosh, et al., 1989). Lifting strength was signifi- ...
An organically modified montmorillonite (MMT) was compounded with polybutylene terephthalate (PBT) in a twin-screw extruder. The organoclay PBT nanocomposites were then injection molded by conventional and microcellular methods. Nitrogen was used as the blowing agent. The effect of organoclay content, organoclay size (8 and 35mm), and speed of the screw (80 and 100rpm) on the mechanical and thermal properties were investigated. The results showed that when the MMT content was 1.0wt.%, the nanocomposites have maximum tensile strength, wear resistance, and cell density. Moreover, the larger the particle size, the greater the tensile strength. The screw speed during compounding also affected the mechanical strength. The higher speed of the screw increased the tensile strength of the nanocompo...
... In fact, for dynamic loading, the ultimate compressive strength can be more than doubled (Bischoff and Perry 1991), whereas the ultimate uniaxial ...
... The measured elastic modulus was fairly close to the predicted value, but the ultimate compressive strength (UCS) was quite a bit below the MSC ...
Corrosion- and Wear Resistant Silicon Containing Chromium-Manganese and Nickel-Chromium-Manganese Nonmagnetic Steels with Increased Strength and Toughness for Reliable Work at Normal and Cryogenic Temperatures
Engineering ceramics have excellent properties such as high strength, high hardness and high heat resistance compared with metallic materials. To apply the ceramic in fast reactor environment, it is necessary to evaluate the sodium compatibility and the influence of sodium on the mechanical properties of ceramics. In this study, the influence of high temperature sodium on the mechanical properties of sintered ceramics of conventional and high purity Al_2O_3, SiC, SiAlON, AlN and unidirectional solidified ceramics of Al_2O_3/YAG eutectic composite were investigated by means of flexure tests. Test specimens were exposed in liquid sodium at 823K and 923K for 3.6Ms. There were no changes in the flexural strength of the conventional and high purity Al_2O_3, AlN and Al_2O_3/YAG eutectic composite after the sodium exposure at 823K. On the contrary, the decrease in the flexural strength was observed in SiC and SiAlON. After the ...
The majority of research on homeless youth has focused on the multitude of problems faced by this vulnerable population. The current study, while acknowledging the hazards of life on the streets, seeks to explore the personal strengths and informal resources street youth rely on to navigate their environments. Qualitative data from seven focus groups conducted with street youth ages 18?24 were analyzed using content analysis. These data, rich with interactions among youth participants, highlight three important themes: developing ?street smarts,?? existence of personal strengths, and informal resources relied upon by youth to survive. Results provide valuable insights into the strengths of homeless youth that can be useful to providers in assessing street youths? service needs and increasi...
The purpose was to identify human in vitro cell lines with a high relative cellular sensitivity to fast neutrons as compared to photons and to examine their relationship to intrinsic photon radiosensitivity and cellular proliferation kinetics. The clonogenic cell survival following exposure to low LET, 4 MeV photons or, high LET, 62.5 MeV (p #-># Be"+) fast neutrons and the cell survival following exposure to low LET, 4 MeV photons or, high LET, 62.5 MeV (p #-># Be"+) fast neutrons and the cell kinetic parameters of 30 human in vitro cell lines, covering a wide range of histologies, were analyzed alone and with previously published data of Fertil and Malaise. The relative survival at 1.6 Gy of neutrons (SF_1_._6) compared to 2 Gy of photons (SF_2) and the cell kinetic parameters of the 30 cell lines were also compared. The relative lethality of 62.5 MeV fast neutrons was ...
Real-time neutron powder diffraction and small-angle scattering techniques have been developed on the TOF diffractometer DN-2 at the IBR-2 pulsed reactor at JINR (Dubna) with a total flux on the sample of 10{sup 7} neutrons cm{sup -2}s{sup -1} and a resolution of about 1%. A special arrangement of the detector system ensures a high counting rate of diffracted neutrons. Depending upon sample type and experimental conditions, the measuring time t{sub s} of one neutron pattern varies from a few minutes to several seconds. The performance of the diffractometer is discussed and typical data are shown to demonstrate current achievements using real-time techniques at a pulsed reactor. (orig.).
Real-time neutron powder diffraction and small-angle scattering techniques have been developed on the TOF diffractometer DN-2 at the IBR-2 pulsed reactor at JINR (Dubna) with a total flux on the sample of 10"7 neutrons cm"-"2s"-"1 and a resolution of about 1%. A special arrangement of the detector system ensures a high counting rate of diffracted neutrons. Depending upon sample type and experimental conditions, the measuring time t_s of one neutron pattern varies from a few minutes to several seconds. The performance of the diffractometer is discussed and typical data are shown to demonstrate current achievements using real-time techniques at a pulsed reactor. (orig.).
The report considers experimental and theoretical works on studying the energy spectra of prompt neutrons emitted in spontaneous fission and neutron induced fission of Minor Actinides. It is noted that neutron spectra investigations were done for only a small number of such nuclei, most measurements, except those of Cf-252, having been carried out long ago by obsolete methods and imperfectapparatus. The works have no detailed description of experiments, analysis of errors, detailed numerical information about results of experiments. A conclusion is made that the available data do not come up to modern requirements. It is necessary to make new measurements of fission prompt neutron spectra of transuranium nuclides important for the objectives of working out a conception of minor actinides transmutation by means of special reactors. (author).
In order to assess various core parameters a reference equilibrium core with Low Enriched Uranium (LEU) fuel for Pakistan Research Reactor (PARR-1) was assembled. Due to increased volume of reference core, the average neutron flux reduced as compared to the first higher power operation. To get a higher neutron flux an irradiation facility was created in centre of the reference equilibrium core where the advantage of the neutron flux peaking was taken. Various low power experiments were performed in order to evaluate control rods worth and neutron flux mapping inside the core. The neutron flux inside the central irradiation facility almost doubled. With this arrangement reactor operation time was cut down from 72 hours to 48 hours for the production of the required specific radioactivity. (author)
Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain quantitative information on the object being imaged.
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain quantitative information on the object being imaged. (orig.).
The Advanced MAPLE is a research reactor design under development as a high-flux neutron source. The main performance goals for the reactor are a high peak thermal neutron flux in a heavy-water reflector tank, and a high average fast neutron flux in a central irradiation facility, with a maximum linear fuel rod rating of less than 120 kW/m. This study investigated the neutronic and reactor design consequences of the use of H_2O coolant as opposed to D_2O. The neutronics results, and several other considerations, indicate that H_2O coolant has a number of advantages. It is suggested that the H_2O coolant option be considered in the design of the Advanced MAPLE reactor. (L.L.) 9 refs., 4 figs., tab.
This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The authors investigated the evolution and radiation characteristics of individual neutron stars and stellar systems. The work concentrated on phenomena where new techniques and observations are dramatically enlarging the understanding of stellar phenomena. Part of this project was a study of x-ray and gamma-ray emission from neutron stars and other compact objects. This effort included calculating the thermal x-ray emission from young neutron stars, deriving the radio and gamma-ray emission from active pulsars and modeling intense gamma-ray bursts in distant galaxies. They also measured periodic optical and infrared fluctuations from rotating neutron stars and search for high-energy TeV gamma rays from discrete celestial sources.
Reliable facility of cyclotron-based real time neutron radiography system has been developed and applied to some industrial components. The equipment for neutron fluoroscopy is based on a sub-compact cyclotron and a LiF/ZnS (Ag) fluorescent screen viewed by a silicon intensifier target TV camera. The real time image is monitored on a CRT, recorded with a standard video recorder and processed by a digital image processor. The effectiveness of our real time neutron radiograph has been demonstrated to be applicable to not only the dynamic observation but also the magnifying and stereoscopic observation of fluoroscopic images.
Differential cross sections for dijet photoproduction in association with a leading neutron using the reaction e{sup +}+p{yields}e{sup +}+n+jet+jet+X{sub r} have been measured with the ZEUS detector at HERA using an integrated luminosity of 6.4 pb{sup -1}. The fraction of dijet events with a leading neutron in the final state was studied as a function of the jet kinematic variables. The cross sections were measured for jet transverse energies E{sub T}{sup jet}>6 GeV, neutron energy E{sub n}>400 GeV, and neutron production angle {theta}{sub n}<0.8 mrad. The data are broadly consistent with factorization of the lepton and hadron vertices and with a simple one-pion-exchange model.
The ground state masses of thirty-nine neutron-rich nuclei from [sup 51]Ca to [sup 72]Ni have been measured using the Time-of-Flight Isochronous (TOFI) spectrometer. Eight of these masses have been measured for the first time and thirty-one are remeasurements of neutron-rich nuclei previously reported. Good agreement between these results and a previous TOFI experiment was observed except for the most neutron-rich isotopes of vanadium through iron with the present results being more bound and in better agreement with theory. The low binding energy of [sup 68]Ni, as indicated by an unreasonably low two-neutron separation energy, suggests the presence of a high-lying, long-lived isomeric state in this nucleus. (orig.)
The ground state masses of thirty-nine neutron-rich nuclei from "5"1Ca to "7"2Ni have been measured using the Time-of-Flight Isochronous (TOFI) spectrometer. Eight of these masses have been measured for the first time and thirty-one are remeasurements of neutron-rich nuclei previously reported. Good agreement between these results and a previous TOFI experiment was observed except for the most neutron-rich isotopes of vanadium through iron with the present results being more bound and in better agreement with theory. The low binding energy of "6"8Ni, as indicated by an unreasonably low two-neutron separation energy, suggests the presence of a high-lying, long-lived isomeric state in this nucleus. (orig.).
Visualization of a liquid metal flow and image processing methods to measure the vector field are carried out by real-time neutron radiography. The JRR-3M real-time thermal neutron radiography facility in the Japan Atomic Energy Research Institute was used. Lead-bismuth eutectic was used as a working fluid. Particles made from a gold-cadmium intermetallic compound (AuCd{sub 3}) were used as the tracer for the visualization. The flow vector field was obtained by image processing methods. It was shown that the liquid metal flow vector field was obtainable by real-time neutron radiography when the attenuation of neutron rays due to the liquid metal was less than l/e and the particle size of the tracer was larger than one image element size digitized for the image processing. (orig.).
Visualization of a liquid metal flow and image processing methods to measure the vector field are carried out by real-time neutron radiography. The JRR-3M real-time thermal neutron radiography facility in the Japan Atomic Energy Research Institute was used. Lead-bismuth eutectic was used as a working fluid. Particles made from a gold-cadmium intermetallic compound (AuCd_3) were used as the tracer for the visualization. The flow vector field was obtained by image processing methods. It was shown that the liquid metal flow vector field was obtainable by real-time neutron radiography when the attenuation of neutron rays due to the liquid metal was less than l/e and the particle size of the tracer was larger than one image element size digitized for the image processing. (orig.).
The proton and neutron densities, root-mean-square (rms) radii of proton density and neutron density, and neutron skin thickness of "4"-"1"0He, "6"-"1"1Li, and "7"-"1"2Be isotopes are calculated using Skyrme-Hartree-Fock method with SLy4, SLy5, SLy6, and SLy7 force parameters. The evaluated results are compared with experimental data. Also, the results of halo nuclei ("6","8He, "1"1Li, and "1"1Be) are compared with the results of other isotopes for selected nuclei having the same neutron configuration.
A number of concrete culverts used to retrievably store drummed, dry, radioactive waste at the Savannah River Site (SRS), were suspected of containing ambiguous quantities of transuranic (TRU) nuclides. These culverts were assayed in place for Pu-239 content using thermal and fast neutron counting techniques. High resolution gamma-ray spectroscopy on 17 culverts, having neutron emission rates several times higher than expected, showed characteristic gamma-ray signatures of neutron emitters other than Pu-239 (e.g., Pu-238, Pu/Be, or Am/Be neutron sources). This study confirmed the Pu-239 content of the culverts with anomalous neutron rates and established limits on the Pu-239 mass in each of the 17 suspect culverts by in-field, non-intrusive gamma-ray measurements.
A number of concrete culverts used to retrievably store drummed, dry, radioactive waste at the Savannah River Site (SRS), were suspected of containing ambiguous quantities of transuranic (TRU) nuclides. These culverts were assayed in place for Pu-239 content using thermal and fast neutron counting techniques. High resolution gamma-ray spectroscopy on 17 culverts, having neutron emission rates several times higher than expected, showed characteristic gamma-ray signatures of neutron emitters other than Pu-239 (e.g., Pu-238, Pu/Be, or Am/Be neutron sources). This study confirmed the Pu-239 content of the culverts with anomalous neutron rates and established limits on the Pu-239 mass in each of the 17 suspect culverts by in-field, non-intrusive gamma-ray measurements.
Thermal hydraulics of a liquid metal is important to design the blanket of a magnetic confined fusion reactor. Since a liquid metal has high thermal and electrical conductivity, the flow characteristics are often different from those of an ordinary liquid like water especially in thermal convection and under a magnetic field. It is difficult to simulate such flows in a liquid metal cooled blanket by water. Flow visualization is a popular method to study thermal hydraulics. Since most of metals are visible by neutron rays, neutron radiography is available to the flow visualization of a liquid metal. The purpose of this study is to develop a visualization technique of the flow in a liquid metal by real-time neutron radiography using the tracer and the dye injection methods. A real-time thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute was used for the visualization ...
Thermal hydraulics of a liquid metal is important to design the blanket of a magnetic confined fusion reactor. Since a liquid metal has high thermal and electrical conductivity, the flow characteristics are often different from those of an ordinary liquid like water especially in thermal convection and under a magnetic field. It is difficult to simulate such flows in a liquid metal cooled blanket by water. Flow visualization is a popular method to study thermal hydraulics. Since most of metals are visible by neutron rays, neutron radiography is available to the flow visualization of a liquid metal. The purpose of this study is to develop a visualization technique of the flow in a liquid metal by real-time neutron radiography using the tracer and the dye injection methods. A real-time thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute was used for the visualization ...
The effect of both dopant and neutron radiation on the optical and thermal properties of polyvinyl chloride (PVC) has been studied. The doped samples with Pb and Cd were irradiated with a 14 MeV-neutron fluence in the range 7-28.8 x 10"9 n/cm"2. The optical energy gap E_o_p exhibits a significant dependence on the type of additive and the neutron irradiation fluence. The specific heat at constant pressure C_p showed a nonmonotonical change with radiation fluence. The results of this study show that PVC:Pb behaves as a crystalline structure which is only slightly affected by neutron irradiation, while PVC:Cd is highly affected. (author).
This paper describes an electronic imaging system for producing real time neutron radiography from a low power research reactor, which will allow inspections of samples with high efficiency, in terms of measuring time and result analysis. This system has been implanted because of its potential use in various scientific and industrial areas where neutron radiography with photographic film could not be applied. This real time system is installed in neutron radiography facility of Argonauta nuclear research reactor, at the Instituto de Engenharia Nuclear of the Comissao Nacional de Energia Nuclear, in Brazil. It is adequate to perform real time neutron radiography of static and dynamic events of samples.
This paper describes an electronic imaging system for producing real time neutron radiography from a low power research reactor, which will allow inspections of samples with high efficiency, in terms of measuring time and result analysis. This system has been implanted because of its potential use in various scientific and industrial areas where neutron radiography with photographic film could not be applied. This real time system is installed in neutron radiography facility of Argonauta nuclear research reactor, at the Instituto de Engenharia Nuclear of the Comissao Nacional de Energia Nuclear, in Brazil. It is adequate to perform real time neutron radiography of static and dynamic events of samples.
To investigate the characteristics of a reactor and a neutron generator, a small scintillation detector with an optical fiber with ThO_2 has been developed to measure fast neutrons. However, experimental facilities where "2"3"2Th can be used are limited by regulations, and S/N ratio is low because the background counts of this detector are increase by alpha decay of "2"3"2Th. The purpose of this study is to develop a new optical fiber detector for measuring fast neutrons that does not use nuclear material such as "2"3"2Th. From the measured and calculated results, the new optical fiber detector which uses ZnS(Ag) as a converter material together with a scintillator have the highest detection efficiency among several developed detectors. It is applied for the measurement of reaction rates generated from fast neutrons; furthermore, the absolute detection efficiency of this detector was obtained ...
Perfect single-crystal neutron interferometers are adversely sensitive to environmental disturbances, particularly mechanical vibrations. The sensitivity to vibrations results from the slow velocity of thermal neutrons and the long measurement time that are encountered in a typical experiment. Consequently, to achieve a good interference solutions for reducing vibration other than those normally used in optical experiments must be explored. Here we introduce a geometry for a neutron interferometer that is less sensitive to low-frequency vibrations. This design may be compared with both dynamical decoupling methods and decoherence-free subspaces that are described in quantum information processing. By removing the need for bulky vibration isolation setups, this design will make it easier to adopt neutron interferometry to a wide range of applications and increase its sensitivity.
Using indigenously developed computer program, coupled neutron gamma multi-group libraries have been generated from MA TXS-NJOY files. The MATXS format contains all the details for each reaction. Temperature and dilution factor dependent cross-sections have been generated and used in discrete ordinates method for benchmark studies of fast critical experiments. We have analyzed criticality benchmarks, which includes CSEWG fast critical benchmarks, "2"3"3U and Pu spheres and enriched uranium spheres using 30-group neutron cross-sections. Neutron and gamma spectra for spheres with point neutron source at the center, are also calculated with 42-group coupled neutron gamma cross-sections. (author)
From optical point of view and due to the magnetic interaction of the cold neutrons with the unpaired electron shell, magnetic materials hae a neutron spin-dependent refractive index n[sup +] [spin up] and n[sup -] [spin down]. Magnetic media such as Fe, Co and Ni react like birefringent uniaxial crystals in ordinary optica. n[sup +] and n[sup -] are the equivalent of the ordinary and extraordinary refractive indices. The specular reflection of spin polarized neutrons which is due to the discontinuity of the magnetic induction at the surface of the ferromagnet is a sensitive probe of surface and interface magnetism. We shall first give the background of the art of polarized neutron optics. Secondly, some recent examples from surface and interface magnetism will be given to illustrate the power of this technique such as the magnetic coupling in thin films and multilayers and flux penetration in ...
The neutron transmutation doping (NTD) method was applied to the initially p-type silicon in order to extend the NTD applications at HANARO. The relationship between the irradiation neutron fluence and the final resistivity of the initially p-type silicon material was investigated. The proportional constant between the neutron fluence and the resistivity was determined to be 2.3473x10{sup 19} n {omega} cm{sup -1}. The deviation of the final resistivity from the target for almost all the irradiation results of the initially p-type silicon ingots was at a range from -5% to 2%. In addition, the burn-up effect of the boron impurities, the residual {sup 32}P activity and the effect of the compensation characteristics for the initially p-type silicon were studied. Conclusively, the practical methodology to perform the neutron transmutation doping of the initially p-type silicon ingot was established.
The neutron transmutation doping (NTD) method was applied to the initially p-type silicon in order to extend the NTD applications at HANARO. The relationship between the irradiation neutron fluence and the final resistivity of the initially p-type silicon material was investigated. The proportional constant between the neutron fluence and the resistivity was determined to be 2.3473x1019 n ? cm-1. The deviation of the final resistivity from the target for almost all the irradiation results of the initially p-type silicon ingots was at a range from -5% to 2%. In addition, the burn-up effect of the boron impurities, the residual 32P activity and the effect of the compensation characteristics for the initially p-type silicon were studied. Conclusively, the practical methodology to perform the neutron transmutation doping of the initially p-type silicon ingot was established.
The Advanced Neutron Source will be a new world-class facility for research using hot, thermal, cold, and ultra-cold neutrons. The heart of the facility will be a 330-MW (fission), heavy-water cooled and heavy-water moderated reactor. The reactor will be housed in a central reactor building, with supporting equipment located in an adjoining reactor support building. An array of cold neutron guides will fan out into a large guide hall, housing about 30 neutron research stations. Appropriate office, laboratory, and shop facilities will be included to provide a complete facility for users. The ANS is scheduled to begin operation at the Oak Ridge National Laboratory early in the next decade. This PDR document defines the plant-level requirements for the design, construction, and operation of ANS. It also defines and provides input to the individual System Design Description (SDD) documents. Together, this ...
Both travelers were members of a nine-person US delegation that participated in an international workshop on accelerator-based 14 MeV neutron sources for fusion materials research hosted by the University of Tokyo. Presentations made at the workshop reviewed the technology developed by the FMIT Project, advances in accelerator technology, and proposed concepts for neutron sources. One traveler then participated in the initial meeting of the IEA Working Group on High Energy, High Flux Neutron Sources in which efforts were begun to evaluate and compare proposed neutron sources; the Fourth FFTF/MOTA Experimenters' Workshop which covered planning and coordination of the US-Japan collaboration using the FFTF reactor to irradiate fusion reactor materials; and held discussions with several JAERI personnel on the US-Japan collaboration on fusion reactor materials.
A 2.45 MeV neutron time-of-flight spectrometer was designed and built for measurements of neutron energy spectra from the JT-60U Tokamak. The spectrometer consists of two fast plastic scintillators (50 cm{sup 2} and 1800 cm{sup 2}, thickness: 2 cm) where each detector is located on two constant time-of-flight spheres. The time-of-flight spheres have radius of 1 m which gives a neutron flight length of {approx}164 cm and a time-of-flight of {approx}92 ns for 2.45 MeV source neutrons. The calculated spectrometer efficiency and resolution are 2.8 x 10{sup -2} cm{sup 2} and 105 keV (4.3%), respectively. The energy resolution corresponds to a time resolution of 2.0 ns. The spectrometer will measure neutrons in a vertical line-of-sight, {approx}9 m from the plasma center. For a total neutron emission of 10{sup 16} n/s, the countrate in the first scattering detector, ...
Prompt fission neutron energy spectra for "2"3"5U and "2"3"9Pu have been measured for fission neutron energies greater than the energy of the incident neutrons inducing fission. The measurements were undertaken to investigate the shape dependence of the fission neutron spectra upon both the incident neutron energy and the mass of the nucleus undergoing fission. Measurements were made for both nuclides at incident neutron energies of 0.50, 1.50, 2.50 and 3.50 MeV. The data are presented either as relative yields or as ratios of measured spectra to that of "2"3"5U at 0.50 MeV. Incident neutrons were produced by the "7Li(p,n)"7Be reaction using a pulsed, bunched proton beam from the 5.5 MV Van de Graaff accelerator at the University of Massachusetts Lowell Radiation Laboratory. Fission neutrons were detected by a thin ...
Full text: Semiconductor detectors coated with boron or lithium compounds have been studied for neutron detection for decades but, until recently, have been limited to thermal neutron detection efficiencies of less than 5%. We reported previously on development and simulation studies of perforated detectors whose perforations are filled with neutron-reactive material in order to produce higher detection efficiencies. Incorporation of bare and cadmium-backed detectors into battery-powered devices with low-power electronics enables us to produce compact personal neutron dosimeters that provide LED readout of counts, which can be related approximately to neutron dose. We report here on experimental studies with such compact devices; devices capable of direct readout in dose units are anticipated. The thermal and epithermal neutron flux densities from the tangential ...
Prompt fission neutron spectrum measurements at the University of Massachusetts Lowell 5.5 MV Van de Graaff accelerator laboratory require that the neutron detector efficiency be well known over a neutron energy range of 100 keV to 20 MeV. The efficiency of the detector, has been determined for energies greater than 5.0 MeV using the Weapons Neutron Research (WNR) white neutron source at the Los Alamos Meson Physics Facility (LAMPF) in a pulsed beam, time-of-flight (TOF) experiment. Carbon matched polyethylene and graphite scatterers were used to obtain a hydrogen spectrum. The detector efficiency was determined using the well known H(n,n) scattering cross section. Results are compared to the detector efficiency calculation program SCINFUL available from the Radiation Shielding Information Center at Oak Ridge National Laboratory.
Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, ...
Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, ...
Plutonium metal is produced by reducing PuF{sub 4} prepared from PuO{sub 2} by fluorination. Both fluorination and reduction are batch processes at the Los Alamos Plutonium Facility. The conversion of plutonium oxide to fluoride greatly increases the neutron yield, a result of the high cross section for alpha-neutron ({alpha},n) reactions on fluorine targets compared to the (more than 100 times) smaller {alpha},n yield on oxygen targets. Because of the increase, total neutron counting can be used to monitor the conversion process. This monitoring ability can lead to an improved metal product, reduced scrap for recycle, waste reduction, minimized reagent usage, and reduce personnel radiation exposures. A new stirred-bed fluorination process has been developed simultaneously with a recent evaluation of an automated neutron-counting instrument for quantitative process monitoring. ...
A real-time neutron radiography system was installed at the neutron radiography facility of Sumitomo Heavy Industries where a sub-compact cyclotron is used as a neutron generator and nominal neutron flux was observed as 1.1 x 10"6 n/cm"2/sec. Preliminary tests were made for various kinds of such components as collimators, scintillators, cameras and lenses and the system was chosen to give the highest quality images. Especially for the scintillator screen, screening tests were carried out for compounds of LiF/ZnS(Ag) and Gd_2O_3/ZnS(Ag) by radiographic film method. The neutron radiography image was converted to fluorescent images by means of the converter and observed by a SIT type TV camera. The video signal was directly displayed on a CRT or after processed with digital image processing devices. The characteristics of this system as for the resultant resolution are presented ...
Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal ...
Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal ...
An experimental study of the {sup 241}Am incineration in a high-intensity thermal neutron flux was carried out at the high-flux reactor of the Institut Laue-Langevin in Grenoble. The combination of nuclear {gamma}-ray spectroscopy and off-line mass spectrometry methods made possible the measurement of several parameters of the transmutation chain and the first experimental determination of the unknown {sup 242gs}Am thermal neutron capture cross section, which plays an essential role in the {sup 241}Am incineration process. During a 19 days irradiation in a thermal neutron flux of 5.6x10{sup 14} n/(s cm{sup 2}), (46{+-}5)% of the initial {sup 241}Am was transmuted by neutron capture of which (22{+-}8)% was incinerated by nuclear fission. A value of the thermal neutron cross section of {sup 242gs}Am(n,{gamma}) of (330{+-}50) barns was obtained. We show that this keeps the option open ...
This report describes a neutron fluence assessment performed for the Kori Unit 3 pressure vessel beltline region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the beltline region of the pressure vessel. After Cycle 16 of reactor operation, 2nd Ex-Vessel Neutron Dosimetry Program was instituted at Kori Unit 3 to provide continuous monitoring of the beltline region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry ...
Employing a recently developed Monte-Carlo model, we study the fission of 240Pu induced by neutrons with energies from thermal to just below the threshold for second chance fission. Current measurements of the mean number of prompt neutrons emitted in fission, together with less accurate measurements of the neutron energy spectra, place remarkably fine constraints on predictions of microscopic calculations. In particular, the total excitation energy of the nascent fragments must be specified to within 1MeV to avoid disagreement with measurements of the mean neutron multiplicity. The combination of the Monte-Carlo fission model with a statistical likelihood analysis also presents a powerful tool for the evaluation of fission neutron data. Of particular importance is the fission spectrum, which plays a key role in determining reactor criticality. We show that our approach can be used ...
Neutron radiography has been put to practical use in foreign countries as one of nondestructive inspection technologies, but in Japan, its application to other scientific fields is mainly researched. The reason is, the neutron radiography apparatuses installed in Japan are hard to be industrially utilized for a number of reasons, but also the characteristics of neutron radiography are not clearly established, and it is not standardized. The part from a collimator through an object to a detector is called ``upstream``, the part of an image detector is called ``midstream``, and the part of image processing is called ``downstream``. The nonparallel property of beam, image distortion and the lack of sharpness, beam quality and the interaction of neutron beam with an object are discussed about the upstream. The intensity of neutron beam, the energy spectra, the effective total ...
The system of the early forecast of radiation hazardous fluxes of solar cosmic rays in space on the basis of the real time neutron monitors data obtained by the NMDB (Neutron Monitor Data Base) network is created. The forecast system is based on a short cut technique of definition of a spectrum of solar protons from the data of the limited number of neutron monitor stations and with a simplified procedure of accounts. It is shown that the results of computations of solar proton spectra with the short-cut technique little differ from spectra obtained with a complete technique at energies less than 5 GeV. Thus the good agreement between derived from the neutron monitor data intensities of solar protons in an energy range of hundreds MeV with the data of direct measurements of solar protons at GOES-11 spacecraft is observed. The maximum of increase on neutron monitors outstrips on ...
In many experiments involving fast neutrons generated in nuclear reactions initiated by accelerator produced charged particle beams, it is important to be able to determine accurately the neutron yield from the target. A detector suitable for such applications should have: a constant efficiency over a large energy range; a fast time response; and the ability to discriminate between gamma rays and neutrons. The authors have constructed a open-quotes black neutron detectorclose quotes based on the design of Poenitz that has these characteristics. At the Lowell Van de Graaff accelerator laboratory neutrons are produced via the "7Li(p,n)"7Be reaction using a pulsed proton beam which impinges on metallic lithium targets. The pulsed beam enables the detector to be used in a time-of-flight spectrometer. Use of BC501 liquid scintillator permits neutron-gamma ...
This article describes acoustic methods used in the in-service inspection of the dams and peripheral concrete structures of the Toktogul, Kurpsai, and Bratsk hydroelectric and pumped storage plants. The tests were conducted to assess the compression strength, elasticity, and tensile strength of the concretes. Comparative evaluations against drill core studies proved the acoustic methods to be sufficiently accurate in predicting aging behavior and loss of mechanical and physical integrity in the concretes.
The influence of various alloy elements on tensile strength of the eutectic, directionally solidified superalloy 73 C was determined. The tensile properties of the base alloy has been increased by Al, Y and C as alloying elements, while Ni and Ti showed a decreasing effect (alloy softening). However, ductility and thermo-fatigue behaviour had been influenced in a positive way by these elements. The specific meachanism caused by the different elements are discussed. (orig.).
In this paper structure and mechanical properties of PBZT and PBO fibers are briefly discussed. One limitation of the high-modulus polymeric fibers and ultrahigh-modulus carbon fibers in reinforced composites is their poor compressive strength. Issues related to the compressive strength of polymeric and carbon fibers are considered. 62 references, 7 figures, 4 tables.
The influence of heat treatment on the structure, mechanical properties and fracture peculiarities of high-strength (#alpha#+#beta#)-titanium alloy VT22 has been studied. It is ascertained that thermal cycling and subsequent high-temperature aging permit to reduce considerably crack growth rate. Thermal cycling is realized in the following mode: heating in #beta#-region, cooling and allowance in (#alpha#+#beta#)-region, heating in #beta#-region.
Novel in situ polymerizable liquid three-arm biodegradable oligomeric polyesters based upon glycolic acid (GA), L-lactic acid (LLA), and their copolymers are synthesized and characterized. Injectable and in situ curable polymer neat resins and their composites formulated with bioabsorbable beta-tricalcium phosphate are prepared at room temperature using photo- and redox-initiation systems, respectively. The cured neat resins show the initial compressive yield strength (YCS, MPa), modulus (M, MPa), ultimate compressive strength (UCS, MPa), and toughness (T, kN mm), ranging from 4.0 to 20.1, 201.5 to 730.2, 82.7 to 310.5, and 1.02 to 3.93. The cured composites show the initial YCS, M, UCS and T, ranging from 27.7 to 56.4, 1440 to 4870, 81.6 to 158.9, and 0.94 to 1.97. Increasing GA/LLA ratio increases all the initial compressive strengths of both neat resins and composites. Increasing filler content increases YCS and M but ...
Ultrafine grained steels with different carbon contents were produced through warm caliber rolling and evaluated for their stress-strain behavior along with the reduction in area. It was found that the reduction in area-tensile strength balance is far better than the conventional ferrite+pearlite steels and even superior to bainitic steels for all materials tested in the present study.
The examples discussed demonstrate that in order to improve further the high-temperature strength properties of (monocrystalline) nickel-base superalloys, it is expedient to follow two parallel routes, namely alloy development, on the one hand, and suitable modifications of the microstructure by appropriate thermal and mechanical treatments, on the other hand. (orig.)
A tobermorite/hydroxyapatite composite was prepared by hydrothermal treatment using diatomaceous earth, ?-tricalcium phosphate and slaked lime starting materials. The XRD patterns of the composite confirmed that tobermorite and hydroxyapatite were formed after the hydrothermal process. The bending strength of the composite reached a level higher than 9?MPa after the hydrothermal process. The development of the bending strength was due to the formation of tobermorite and hydroxyapatite during the hydrothermal process. The composite had a high specific surface area due to these newly formed crystals.
The paper presents results of studies on the effect of heat treatment on strength and pattern of 40Kh steel impact failure. Loading levels corresponding to macroscopic spalling microdamage initiation in the material are determined for three initial states. Metallographic study on the spalling failure pattern for 40Kh steel in different initial states and data on microhardness measurement are presented.
A number of alloys of zirconium have been investigated as part of a program aimed at improving the high-temperature tensile and creep strength of zirconium. These alloys include aluminum, beryllium, lead, magnesium, molybdenum, niobium, tantalum, tin, titanium, tungsten, vanadium, and zinc, binary and ternary alloys. The data indicate that aluminum, lead, molybdenum niobium, tin, titanium, tungsten, and vanadium can be used successfully to harden zirconium, and that aluminum, tin, titanium, and vanadium are particularly effective in maintaining the strength of zirconium at elevated temperatures.
The reconstruction of segmental defect in long bone is a clinical challenge. Multiple surgeries are typically required to restore the structure and function of the affected defect site. In order to overcome this defect a biodegradable bone tissue engineering scaffold is used. This scaffold acts as a carrier of proteins and growth factors, while also supporting the load that the bone would normally sustain, until the natural bone can regenerate in its place. Work was done to optimize an existing solid free-form scaffold design. The goal of the optimization was to increase the porosity of the scaffold while maintaining the strength of a previously-tested prototype design. With this in mind, eight new designs were created. These designs were drawn using CAD software and then through the use of finite element analysis the theoretical ultimate compressive strength of each design was obtained. Each scaffold design was constructed by casting a ...
Recently the increase of steam temperature and pressure of power plant is required to enhance the thermal efficiency and reduce the CO{sub 2} emission. For the application to advanced USC (Ultra Super Critical) boiler with steam temperature around 700 C, the application of Ni-based alloy such as Alloy617 will be necessary. A new Ni-based alloy USC141 (20Cr-10Mo-2Ti-Al-bal.Ni) with excellent creep rupture strength and low thermal expansion has been developed by Hitachi Ltd. and Hitachi Metals Ltd. as the candidate material for 700 C USC turbine components. In present work, to investigate the possibility for boiler tube application of USC141, its weldability and high temperature strength properties were experimentally examined. The tested material as solution-treated condition shows higher creep rupture strength than that of Alloy617. GTAW (Gas Tungsten Arc Welding) trials of tubular specimen using NIMONIC263 filler wire were ...
Triaxial compression tests following stress paths of constant {sigma}{sub 1} were conducted to determine the shear strength of five processed scrap tire products having different gradations and particle shapes. The interparticle frictional component was separated from the total shear strength according to the energy correction concept proposed by researchers. The experimental results show that all five tire chip products have ultimate internal friction angles of 45{degree} to over 60{degree}. The interparticle frictional component of the strength was fully mobilized and nearly reached a constant value after approximately 5% axial strain. The experimental results confirmed that the strength parameter obtained with constant {sigma}{sub 1} was more reasonable. This finding is supported by field observation in which the tire chips have an angle of repose ranging from 37{degree} to 43{degree} (loosely stock ...
Considerations for longevity of nuclear facilities and ease of decommissioning are of great importance for future nuclear power plants. To this end, a concept of an optimal structural concept for nuclear reactor buildings has been studied: the main feature of this concept is to utilize large-sized, light weight prefabricated members with ultrahigh strength materials. The following two items have been selected to study the prospective structure: (1) Applicability of ultrahigh strength materials for reinforced concrete shear walls (2) Construction using large sized prefabricated members As the first step (1), material and structural tests using ultrahigh strength materials, and the subsequent analysis of those tests for reinforced concrete shear walls, has been conducted. The positive results of this study show a bright future for the use of ultrahigh strength materials for the reinforced concrete shear ...
Since the earliest papers on undulaters were published, it has been known how to calculate the spontaneous emission spectrum from ''short'' undulaters when the magnetic field strength parameter is small compared to unity, or in ''single'' frequency sinusoidal undulaters where the magnetic field strength parameter is comparable to or larger than unity, but where the magnetic field amplitude is constant throughout the undulater. Fewer general results have been obtained in the case where the insertion device is both short, i.e., the magnetic field strength parameter changes appreciably throughout the insertion device, and the magnetic field strength is high enough that ponderomotive effects, radiation retardation, and harmonic generation are important physical phenomena. In this paper a general method is presented for calculating the ...
Weldability and high temperature strength properties of Hastelloy Alloy XR were investigated in order to evaluate the materials performance of base metal and filler metal for the High Temperature Engineering Test Reactor (HTTR) uses. The weldability was examined by means of the chemical analysis in the deposited metals, optical microscopy, FISCO test, hardness measurements and bend test. The high temperature strength properties were investigated through tensile tests at R.T., 800, 900 and 950degC in air, and creep and creep rupture tests at 900 and 950degC in air. The results obtained by each test showed favorable performance. In particular, the bend test which is considered to be critical pass demonstrated low susceptibility to weld cracking through the optimization of B and C contents in the filler metal and by narrowing the groove. Creep rupture strength was nearly equal or higher than those of Hastelloy Alloy XR master ...
Experimental discussions were given on effect of V and W addition on the high temperature strength properties of 12% Cr-15% Mn austenite steels. The test samples were added with W at 0% to 3.5% and V at 0% to 0.5% in addition to C and N, and were given aging treatment or solution treatment. This paper describes the following matters on the results of high-temperature strength measurements and structural observation: A remarkable trend was observed that M23 Cb type carbides precipitate in the aging treatment, wherein aging hardening appears prominently which is attributable to ultra-fine deposits of vanadium nitride (VN) in the V-added material; the V addition is very effective in increasing the high-temperature tensile strength and creep fracture strength as compared with single W addition, wherein the said carbides that accelerate the precipitation as a result of the V addition make a large ...
Recently, weight reduction of vehicles has been of great interest, and consequently, the use of low-density materials in the automotive industry is increasing every year. Materials should not be substituted such a way that material of component parts is simply changed because there is a problem in achieving stiffness and strength. To achieve these requirements, the automobile should be redesigned totally. Aluminum spaceframe is rapidly being adopted as a body structure for accommodating lightness, stiffness and strength requirement. In aluminum spaceframe manufacturing, it is often required to join aluminum tube. But there are few suitable methods for joining aluminum tube, so that much interest has been focused on testing suitable joining methods. Joining by electromagnetic forming(EMF) can be useful method in joining aluminum tube, which offers some advantages compared with the conventional joining method. In this paper, joining by EMF was ...
Research was conducted to determine the effect of electrochemical aging on large area arc-sprayed zinc anodes for cathodic protection of bridges and other reinforced concrete structures. The study focused on the influence of total charge passed and concrete surface preparation on the bonding of the zinc to the concrete. Half of the samples were preheated prior to being arc-sprayed with zinc. The preheated samples had initial bond strengths that were 80% higher than the unheated samples. This difference in bond strength became insignificant after the passage of approximately 200 kC/m{sup 2} (5.2 A-h/ft{sup 2}) and bond strengths for all samples started to decrease after approximately 600 kC/m{sup 2} (15.5 A-h/ft{sup 2}). These changes in bond strength were correlated with observed changes in the permeability of the zinc coating to water, the electrical behavior of the zinc-concrete interface, the charge ...
ObjectivesThe aim of this study was to evaluate the relationship between micro-tensile bond strength (mTBS) and ultimate tensile strength (UTS) of resin composite restorations in cavities filled by a bulk or incremental technique using the micro-tensile test.MethodsClass I cavities (4mm long, 3mm wide, 3mm deep) were prepared into dentine of sixteen human molars. All cavities were bonded with Clearfil SE Bond and restored with AP-X composite with either a bulk or incremental technique. After storage in water for 24h, the teeth were vertically sectioned to yield two slabs. Each slab was sectioned into three sticks. Sticks of one slab were trimmed into an hourglass of 0.7mm2 area at resin-dentine interface for bond strength measurement while the other sticks were trimmed at the centre of the...
The "2"0 "2"1 "2"2Ne("6Li, d)"2"4 "2"5 "2"6Mg reactions have been studied at a bombarding energy of 32 MeV. Alpha particle spectroscopic strengths have been extracted for several low-lying levels by a finite-range distorted wave analysis. These are compared with theoretical predictions. The agreement is good both for relative strengths to different levels within a nucleus and for ground-state strengths relative to the "1"6O("6Li, d) result. Strengths calculated using eigenfunctions determined in large shell-model computations agree well with pure symmetry SU(3) predictions. The "2"1Ne("6Li, d) angular distributions for transitions to the ground-state band of "2"5Mg are characterized by the lower of the two L-transfers allowed for populating each level. For the 3"+(5.24 MeV) unnatural parity level in "2"4Mg, a two-step calculation gives a better account of the data than does a compound nuclear ...
In 1959 Zeldovich pointed out to the possibility of storage in a closed vessel of very slow neutrons with energies below less than or equal to 10"-"7 eV noting that one may achieve the storage time up to the lifetime of a free neutron before #beta#-decay (approx.10"3 sec). This possibility is due to the effective repulsing potential which describes the interaction of slow neutrons with many substances employing a strong suppression of inelastic processes in the reflection of ultracold neutrons (UCN). In a series of experiments beginning 1968 the effective methods were developed of obtaining pure UCN beams from the maxwellian spectrum of thermal neutrons. The UCN beams of intensity about 10"3 n/sec and density up to 10"2 n/liter were obtained at the reactors with thermal neutron flux of 5 x 10"1"3 n/cm"2 sec. Such UCN beam parameters allow to measure easily the ...
A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are ...
A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are ...
Two neutron emesis experiments were conducted at the Armed Forces Radiobiology Research Institute (AFRRI). In both experiments (described as Phase I and Phase II) the radiation dose required to cause emesis in 50% of subjects (ED50) was determined for both neutron reactor and gamma reactor source radiation. Emesis onset, offset and duration times post-exposure are reported. Neutrons were maximized from the reactor by passing the beam through a 15.25 cm (6 in.) thick lead wall to filter out gamma photons. Gamma rays were maximized by thermalizing neutrons in 30.5 cm (12 in.) of water, then absorbing the thermal neutrons in a gadolinium-cadmium shield. In Phase I, 28 dogs were exposed to radiation: 12 were exposed to gamma photons at the rate of 0.69 Gy/min and 16 were exposed to neutrons at 1.2 Gy/min. In Phase II, 58 dogs in 3 groups were exposed to radiation: ...
High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers ...
High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers ...
Concerning the transient phenomenon of solid-gas two-phase flow, an attempt was made to visualize and measure a flow phenomenon in which three-dimensional bubbles occurred, grew and collapsed in the vicinity of a gas injection nozzle while solid particles were circulating. Such a phenomenon could not or hardly be visualized and measured by conventional methods. Such two-phase flow was visualized using neutron radiography, its characteristics measured and the usefulness of the visualization by neutron radiography confirmed. For this purpose, three-dimensional fluidized bed vessels, rectangular or cylindrical-shaped, made of steel or aluminum sheet, were prepared. Polyethylene or glass beads were used as solid particles and activated carbon particles as the tracer. In the experiment, nitrogen gas was blown into the vessel from one nozzle and distributors provided at the bottom of the vessel and exhausted from the top via the exhaust valve, by ...
In the framework of nuclear waste transmutation studies, the Mini-INCA project has been initiated at CEA/DSM with objectives to determine optimal conditions for transmutation and incineration of minor actinides (MA) in high intensity neutron fluxes. Our experimental tools based on alpha- and gamma-spectroscopy of the samples and the development of micro fission chambers could gather either microscopic information on nuclear reactions (total or partial cross sections for neutron capture and/or fission reactions) or macroscopic information on transmutation and incineration potentials. Neutron capture cross sections of selected actinides ({sup 241}Am, {sup 242}Am, {sup 242}Pu, {sup 237}Np) have already been measured at ILL, showing some discrepancies when compared to evaluated data libraries but in overall good agreement with recent data. The studies and possibilities offer by the MEGAPIE project to assess ...
In the framework of nuclear waste transmutation studies, the Mini-INCA project has been initiated at CEA/DSM with objectives to determine optimal conditions for transmutation and incineration of minor actinides (MA) in high intensity neutron fluxes. Our experimental tools based on alpha- and gamma-spectroscopy of the samples and the development of micro fission chambers could gather either microscopic information on nuclear reactions (total or partial cross sections for neutron capture and/or fission reactions) or macroscopic information on transmutation and incineration potentials. Neutron capture cross sections of selected actinides ("2"4"1Am, "2"4"2Am, "2"4"2Pu, "2"3"7Np) have already been measured at ILL, showing some discrepancies when compared to evaluated data libraries but in overall good agreement with recent data. The studies and possibilities offer by the MEGAPIE project to assess neutronic ...
Electron and ion beam dynamics of the PF-1000 facility were investigated for the first time at its upper energy limit (?1 MJ) in relation to neutron emission, the pinch's plasma ('target') characteristics and some other parameters with the help of a number of diagnostics with ns temporal resolution. Special attention was paid to the temporal and the spatial cross correlations of different phenomena. Results of these experiments are in favour of a neutron emission model based on ion beam-plasma interaction with three important features: (1) the plasma target is hot and confined during a few 'inertial confinement times'; (2) the ions of the main part of the beam are magnetized and entrapped around the pinch plasma target for a period longer than the characteristic time of the plasma inductive storage system and (3) ion-ion collisions (both fusion collisions, due to head-on impacts and Coulomb collisions) are responsible for ...
We report the results of the DC magnetization, neutron powder diffraction and neutron depolarization studies on the spin-chain compounds Ca3Co2-xFexO6 (x = 0, 0.1, 0.2 and 0.4). Rietveld refinement of neutron powder diffraction patterns at room temperature confirms the single-phase formation for all the compounds in rhombohedral structure with space group R3-barc. Rietveld refinement also confirms that Fe was doped at the trigonal prism site, 6a (0, 0, 1/4) of Co. The high temperature magnetic susceptibility obeys the Curie-Weiss law; the value of the paramagnetic Curie temperature (?p) decreases as the concentration of iron increases and it becomes negative for x = 0.4. No extra Bragg peak as well as no observable enhancement in the intensity of the fundamental (nuclear) Bragg peaks has been observed in the neutron diffraction patterns down to 30 K. No depolarization of neutron ...
The electromagnetic field due to an air explosion is here studied: neutron and the gamma-rays, generated by neutronic reactions, deposit energy which ionizes atmosphere; recoil electrons are also created by gamma collisions. This data set allows to solve the Maxwell equations which manage the electromagnetic field. The TRIPOLI-2 code studies the coupled neutron-gamma transport in 3D- geometries by the Monte Carlo method. The code has been modified to calculate the photon energy deposited in matter and the recoil electron current created by Compton effect. The method is tested wiht a simple case; then neutron and gamma transport is studied in air kerma, deposited photon energy, electron current are calculated as functions of space and time and the contributions of the different neutronic reactions are separately evaluated. The calculations presented here are only part of studies ...
In the High Flux Reactor (HFR) at Grenoble a new horizontally arranged cold neutron source will be installed that uses liquid deuterium (D_2) as the moderator for cold neutrons. This cold source should provide a high neutron flux, it should be simple in design, and be characterized by high reliability and by safe operation. A high neutron flux calls for installation of the cold source near the HFR core and good moderation requires a D_2 volume of #DELTA#5 litres. Hence, the moderator, contained in a horizontally arranged cylindrical cell of 21 cm diameter and 20 cm length, is installed at the end nearest to the core of a horizontal beam tube of roughly 4.5 m length with an inner diameter of only 23 cm (Fig. 1). The HFR will be equipped with a second cold neutron source. The installation in the existing horizontal beam tube together with the amount of heat released determined the ...
In neutron radiography, as in other forms of NDE, it is sometimes desirable to observe dynamic events. This need has generated increased interest in real-time neutron radiography systems. As in other forms of radiography, a standard method for measuring the image forming capability of real-time systems is necessary in order to compare the various methods and systems used. A technique which has been used extensively in general photography and has been applied in the characterization of several screen-film combinations used in conventional neutron radiography is to determine the imaging system's modulation transfer function (MTF). This gives a graphical representation of the system's spatial resolution capabilities and was therefore chosen as the method for evaluation of the real-time neutron radiography facility at the University of Missouri Research Reactor (MURR). The method used was to image a ...
Because the number of neutrons and gamma rays and the energy spectrum of particles from spontaneous fission are well characterized for {sup 252}Cf, it can be used as a timed source of fission neutrons and gamma rays. The first such usage incorporated a {sup 252}Cf source into gas scintillators. This paper describes a timed source of neutrons and gamma rays made by depositing {sup 252}Cf on one electrode of a parallel plate ionization chamber that can then be used for determining detection-system characteristics. The emission time of neutrons from spontaneous fission has also been determined by recording the emission time of prompt gamma rays from a {sup 252}Cf source (not incorporated into a detector) adjacent to the surface of a solid or liquid scintillator. This well characterized source of neutrons can thus be used as a randomly pulsed source for a variety of applications. This ...
The thermal neutron column of the JRR-2 reactor was remodelled in order to install a medical irradiation facility. The design experience and the cource of this remodelling are presented. At first, the thermal neutron flux was lower than expected, and the expected radiation condition was achieved by the following improvements: (1) removal of graphite from the thermal neutron column to increase the neutron flux, (2) twice increase of bismuth shielding and the shift of its position to improve the shielding effect against gamma ray, (3) application of B{sub 4}C rubber on the both surfaces of the shielding door to suppress the secondary gamma ray generation from the structural materials, (4) LiF tiles are applied on the inner face of the neutron beam exit hole to suppress the secondary gamma ray from the beam exit, and (5) installment a cone-shape polyethylene collimator to relieve the ...
A comprehensive attenuation data of dose equivalent for point isotropic monoenergetic neutron sources up to 400MeV in infinite shields of water, ordinary concrete and iron has been calculated using the ANISN-JR code and a neutron-photon multigroup macroscopic cross section HIL086R. The attenuation factors were fitted to a 4th order polynomial exponent formula, making possible to use easily for point kernel codes. Additional data in finite shielding geometry was also calculated to correct the effect due to infinite medium, giving the maximum correction of 0.23 in the region for more 400 cm distance from neutron source of 400 MeV in iron shield. Effective attenuation length for monoenergetic neutrons have been studied in detail. Subsequently, it was shown that the attenuation length was strongly dependent upon the penetration length and the Moyer`s formula using a single attenuation length brought large ...
The research on the therapy of brain tumors and others by the thermal neutron irradiation using research reactors is to kill tumor cells by accumulating boron at a tumor part, and using {alpha} particles and {sup 7}Li generated by {sup 10}B(n, {alpha}){sup 7}Li reaction of thermal neutrons, which is known as boron neutron capture therapy (BNCT). In Japan Atomic Energy Research Institute, the medical irradiation facility was installed in the thermal neutron column of the JRR-2, and as of March, 1994, 22 cases of irradiation have been carried out. In order to monitor the variation of thermal neutron flux during irradiation, the real time measurement using a simultaneous monitor is carried out, but there is the variation of measured values in the Si semiconductor, p-n junction detector possibly due to its direction dependence. The experiment was carried out to quantity the direction ...
The purpose of this study was to evaluate the resin-dentin interfacial morphology and shear bond strength of several new and experimental dentin bonding systems classified as single-bottle/total etch, multi-step/total etch, and self-etching. Class 1 and 5 cavities were prepared from freshly extracted permanent molars and restored with composite resin. Each bonded sample was cross sectioned and one-half was completely demineralized and deproteinized, while the other half was polished along the cut surface to permit measurement of the thickness of resin-infiltrated dentin layer (RIDL) within intertubular dentin (iRIDL) and around the peritubular walls (pRIDL) of resin tags by SEM. Shear bond strength was measured for all the systems 2 minutes after photocuring. SEM showed iRIDL and resin tags of different morphology depending on material and dentin location. The iRIDL was thinner in superficial dentin and thicker in deep dentin. Peritubular RIDL ...
The isomeric and {beta}-decay properties of neutron-rich {sup 53-57}Sc and {sup 53,54}Ca nuclei near neutron number N = 32 are reported, and the low-energy level schemes of {sup 53,54,56}Sc and {sup 53-57}Ti are presented. The low-energy level structures of the {sub 21}Sc isotopes are discussed in terms of the coupling of the valence 1f{sub 7/2} proton to states in the corresponding {sub 20}Ca cores. Implications with respect to the robustness of the N = 32 subshell closure are discussed, as well as the repercussions for a possible N = 34 subshell closure.
Amongst the minor actinides issued from the spent nuclear fuel, {sup 241}Am is present in high concentration and contributes significantly to the long-term radiotoxicity of nuclear waste. A major uncertainty was present in the transmutation chain of {sup 241}Am when irradiated by a high intensity thermal neutron flux. This uncertainty was brought about by the poor knowledge of the {sup 242gs}Am neutron capture cross section. A dedicated experiment has been performed at the Institut Laue-Langevin in Grenoble, which gives a definitive experimental answer to this problem.
Amongst the minor actinides issued from the spent nuclear fuel, "2"4"1Am is present in high concentration and contributes significantly to the long-term radiotoxicity of nuclear waste. A major uncertainty was present in the transmutation chain of "2"4"1Am when irradiated by a high intensity thermal neutron flux. This uncertainty was brought about by the poor knowledge of the "2"4"2"g"sAm neutron capture cross section. A dedicated experiment has been performed at the Institut Laue-Langevin in Grenoble, which gives a definitive experimental answer to this problem.
The conceptual design of an ohmically heated, reversed-field pinch (RFP) operating at /approximately/5-MW/m/sup 2/ steady-state DT fusion neutron wall loading and /approximately/124-MW total fusion power is presented. These results are useful in projecting the development of a cost effective, low input power (/approximately/206 MW) source of DT neutrons for large-volume (/approximately/10 m/sup 3/), high-fluence (3.4 MW yr/m/sup 2/) fusion nuclear materials and technology testing. 19 refs., 15 figs., 9 tabs.
A calorimetric-time-of-flight (CTOF) technique was used for real-time, high-precision measurement of neutron spectrum at the angle of 175 degrees from the initial proton beam direction, which hits a face plane of a cylindrical iron target of 20 cm in diameter and 25 cm thick. A comparison was performed between the neutron spectra predicted by the MARS and the MCNPX code systems and measured by experiments for 0.4-, 0.6-, 0.8-, 1.0-, and 1.2-GeV protons.
The effect of high energy neutron irradiation (E > 1 MeV) on the superconducting transition temperature, Tsub(c), of the A-15 compound Mo_3Os is reported. Tsub(c) was found to decrease with increasing neutron dose, but at a rate considerably less than observed in other A-15 compounds composed of non-transition metals. The results lend support to the idea that the effect of ordering on Tsub(c) is smaller for A-15 compounds composed only of transition metals than those composed of transition and non-transition metals. (author).
With 13 experimental facilities under construction to become available during the first year of SINQ operation, a nearly complete suite of options for users will be made available to carry out research with neutrons at PSI. Three more facilities are under design and will come on line somewhat later. To complete the suite, three more specialized instruments are being evaluated. SINQ being a novel neutron source concept, significant scope for improvement is also seen on the source side. It is a major goal of PSI to exploit these opportunities and to make - among others - use of neutron instruments to carry out the necessary research. (author) 9 figs., 1 tab., 11 refs.
We have measured the neutron capture and fission cross section of "2"3"3U at the neutron time-of-flight facility n-TOF at CERN in the energy range from 1 eV to 1 MeV with high accuracy by using a high performance 4#pi# BaF_2 Total Absorption Calorimeter (TAC) as a detection device. The method, based on the shape analysis of the TAC energy response, allowing to disentangle between #gamma#'s originating from fission and capture will be presented as well as the first very preliminary results. (authors)
This paper discusses the stationary neutron radiography system (SNRS) with respect to the component positioning systems (CPSs) and the rationale behind their design. As design work is on-going at science Applications International Corporation, this report gives a current update of progress. The SNRS has four separate radiography bays, Bays 1 through 4. The first three bays have automated positioning systems for real-time and near real-time neutron radiography of aircraft components. Bay 4 has been designed to accommodate components from the solid rocket booster, but will be used first for film radiography of pyrotechnic components.
Subcritical source-driven noise measurements are simultaneous Rossia and randomly pulsed neutron measurements that provide measured quantities that can be related to the subcritical neutron multiplication factor. In fact, subcritical source-driven noise measurements should be performed in lieu of Rossia measurements because of the additional information that is obtained from noise measurements such as the spectral ratio and the coherence functions. The basic understanding of source-driven noise analysis measurements can be developed from a point reactor kinetics model to demonstrate how the measured quantities relate to the subcritical neutron multiplication factor.
The improved facilities of the ISOLDE isotopic separator on-line with the 600 MeV synchrocyclotron at CERN opened the possibility to reach nuclei very far from stability (as far as 22 neutrons deficient in the Cs region and 27 neutrons deficient in the Hg region). Simultaneously the development of on-line spectrometry allowed the study of nuclei with very short half-lives and low counting rates. Results recently obtained in the odd-A iridium region are presented after a short summary of recent on-line devices developments and results. (Auth.).
The McMaster Neutron Radiography Facility (MNRF) is fortunate to own the only Real-Time Neutron Radiography system in Canada. Current research at the MNRF involves the visualization of gas-liquid and gas-solid two-phase flow in complex channels, such as nuclear fuel channels, using light water, heavy water, freon-134A, slurries, and other fluids. Other research at the MNRF has examined single-phase flow, material purity, film deposition, turbine blades, and automotive parts.
The response of a real time neutron dosemeter using a thin LiF target sandwiched between tow parallel surface barrier semiconductor detectors is studied for different neutron distributions and different angles of incidence. Calculations of the response function defined for a simultaneous detection by the two detectors of the particles emitted when the reaction "6Li(n,t)#alpha# occurs in the target are fulfilled by geometrical considerations of the reaction kinematics and the differential cross section variations. Finally, the efficiency of the studied detection systems is analyzed for dosimetric uses. (author).
The #gamma#-radiation following thermal neutron capture in "1"0"0Mo has been studied by singles and coincidence measurements. A "1"0"1Mo level scheme has been deduced and is compared with the results of previous (d,p), (n,#gamma#) and "1"0"1Nb decay studies. The existence of the first excited state at 13.51 keV has been confirmed. The present data yield a neutron binding energy of 5398.4 KeV. (Auth.).
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has been developed at the University of Texas reactor. The facility produced good-quality radiographs and two-dimensional tomograms. Further developments have been recently accomplished. A computer software has been developed to automate and expedite the data acquisition and reconstruction processes. Volume tomographic visualization using Interactive Data Language (IDL) software has been demonstrated and will be further developed. Volume tomography provides the additional flexibility of producing slices of the object using software and thus avoids redoing the measurements.
This report is a summary of the progress and research produced for the Idaho National Engineering and Environmental Laboratory (INEEL) Boron Neutron Capture Therapy (BNCT) Research Program for calendar year 1996. Contributions from the individual investigators about their projects are included, specifically, physics: treatment planning software, real-time neutron beam measurement dosimetry, measurement of the Finnish research reactor epithermal neutron spectrum, BNCT accelerator technology; and chemistry: analysis of biological samples and preparation of {sup 10}B enriched decaborane.
Epoxy-resin based neutron shielding material, NS-4-FR, is used for spent fuel transport and/or storage cask. In this paper the outline of thermal aging test performed to evaluate the heating effect on this neutron shielding material, NS-4-FR, is introduced. The test is consisted of two kinds of thermal aging test, one is 'Basic Test' and the other is 'Block Heating Test'. The former is cooperatively performed by ten Japanese Electrical Power Companies, and the latter is done by GESC and NOF Corporation. (authors)
Epoxy-resin based neutron shielding material, NS-4-FR, is used for spent fuel transport and/or storage cask. In this paper the outline of thermal aging test performed to evaluate the heating effect on this neutron shielding material, NS-4-FR, is introduced. The test is consisted of two kinds of thermal aging test, one is 'Basic Test' and the other is 'Block Heating Test'. The former is cooperatively performed by ten Japanese Electrical Power Companies, and the latter is done by GESC and NOF Corporation. (authors)
The prompt neutron spectra of {sup 241}Am, {sup 242m}Am, and {sup 243}Am were evaluated for the next version of Japanese Evaluated Nuclear Data Library, using the methodology developed by the authors. The method is based on the Madland-Nix theory with some improvements to consider the multimodal nature of the fission process, and shell effects on the level density parameters and the neutron multiplicity from light and heavy fragments. The results were compared with previous evaluations. (authors)
Neutron deficient nuclei with mass numbers A {approx} 90 and 40 {<=} Z {<=} 44 have been studied making use of the Osiris and Nordball spectrometers. The high spin states of these nuclei and their electromagnetic decay properties are compared to shell model calculations based on the core {sup 88}Sr and using different parametrizations of the residual interaction. The dependence of the mean square deviations of experimental and theoretical level energies, branching ratios, and transition probabilities on the neutron numbers N = 46-50 and the validity of seniority as a good quantum number are discussed. (orig.).
The aim of this thesis is the study of new systems devoted to the real time neutron spectrometry and dosimetry. The microelectronics technologies have been used to research a micro system integrating sensor and data processing in real time. The multi range sensor is based on many pair of semiconductor diodes placed face to face and covered by lithium fluoride. The sensor has been designed and its behavior has been simulated. Its operating in reference neutrons beams has been analyzed. (A.L.B.)
Beta-decay studies of the new neutron-rich isotopes sup(58,59)Cr, "6"3Mn, sup(66,67)Co and "6"9Ni, yielding distinctly shorter half-lives than the corresponding theoretical predictions, are presented. The influence of the short half-lives on the r-process calculations of nuclear abundances is discussed. It is concluded that a significantly higher neutron density than the one obtained from explosive helium burning in supernovae is needed to reproduce the observed abundances around A = 80. (orig.).
A diagnosis of the refrigerant flows in a refrigerator was carried out by real-time neutron radiography. The thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute and the real-time image processing system developed by Musashi Institute of Technology were used. Freon evaporating flows in the evaporator, condensing flows in the condenser, flashing flows in the capillary tube and flows in the accumulator were visualized and the dynamic behaviors under practical conditions were clarified. In the case of the capillary tube of 0.8 mm i.d., a cooled-CCD camera was utilized. (orig.).
Alpha-particle emission induced by neutron bombardment of carbon has been studied from threshold to over 30 MeV using the spallation neutron source at WNR/LAMPF. Targets include thin foils of CH{sub 2} and thicker foils of CH and polycrystalline graphite. Comparisons are made with evaluated data. Values for KERMA (kinetic energy released in materials) based on the results will be presented and compared with those obtained through other experimental approaches.
The isomeric and ?-decay properties of neutron-rich 53-57Sc and 53,54Ca nuclei near neutron number N=32 are reported, and the low-energy level schemes of 53,54,56Sc and 53-57Ti are presented. The low-energy level structures of the 21Sc isotopes are discussed in terms of the coupling of the valence 1f7/2 proton to states in the corresponding 20Ca cores. Implications with respect to the robustness of the N=32 subshell closure are discussed, as well as the repercussions for a possible N=34 subshell closure.