WorldWideScience

Sample records for intrinsic l2-10 kev

  1. The 2-79 keV X-ray spectrum of the Circinus galaxy with NuSTAR, XMM-Newton, and Chandra: a fully Compton-thick active galactic nucleus

    International Nuclear Information System (INIS)

    Arévalo, P.; Bauer, F. E.; Puccetti, S.; Walton, D. J.; Fuerst, F.; Grefenstette, B. W.; Harrison, F. A.; Madsen, K. K.; Koss, M.; Boggs, S. E.; Craig, W. W.; Brandt, W. N.; Luo, B.; Brightman, M.; Christensen, F. E.; Comastri, A.; Gandhi, P.; Hailey, C. J.; Madejski, G.; Marinucci, A.

    2014-01-01

    The Circinus galaxy is one of the closest obscured active galactic nuclei (AGNs), making it an ideal target for detailed study. Combining archival Chandra and XMM-Newton data with new NuSTAR observations, we model the 2-79 keV spectrum to constrain the primary AGN continuum and to derive physical parameters for the obscuring material. Chandra's high angular resolution allows a separation of nuclear and off-nuclear galactic emission. In the off-nuclear diffuse emission, we find signatures of strong cold reflection, including high equivalent-width neutral Fe lines. This Compton-scattered off-nuclear emission amounts to 18% of the nuclear flux in the Fe line region, but becomes comparable to the nuclear emission above 30 keV. The new analysis no longer supports a prominent transmitted AGN component in the observed band. We find that the nuclear spectrum is consistent with Compton scattering by an optically thick torus, where the intrinsic spectrum is a power law of photon index Γ = 2.2-2.4, the torus has an equatorial column density of N H = (6-10) × 10 24 cm –2 , and the intrinsic AGN 2-10 keV luminosity is (2.3-5.1) × 10 42 erg s –1 . These values place Circinus along the same relations as unobscured AGNs in accretion rate versus Γ and L X versus L IR phase space. NuSTAR's high sensitivity and low background allow us to study the short timescale variability of Circinus at X-ray energies above 10 keV for the first time. The lack of detected variability favors a Compton-thick absorber, in line with the spectral fitting results.

  2. H(2s) excitation in 10-100 keV H+ - H collisions

    International Nuclear Information System (INIS)

    Higgins, D.P.; Geddes, J.; Gilbody, H.B.

    1996-01-01

    The authors have used a crossed beam technique to determine cross sections for 2s excitation of H atoms in 10-100 keV collisions. The results extend their previous 4-26 keV measurements to intermediate energies where theoretical predictions based on close coupling methods are known to be strongly dependent on the choice of the expansion basis. The 4-100 keV cross sections exhibit an undulatory structure similar to that predicted by some of the many close coupling calculations but good quantitative agreement is shown to be very limited. Close coupling calculations which employ large basis sets at the expense of target states are shown to agree less satisfactorily with experiment than those which include only the dominant 1s capture channel

  3. The NuSTAR Serendipitous Survey: Hunting for the Most Extreme Obscured AGN at >10 keV

    Science.gov (United States)

    Lansbury, G. B.; Alexander, D. M.; Aird, J.; Gandhi, P.; Stern, D.; Koss, M.; Lamperti, I.; Ajello, M.; Annuar, A.; Assef, R. J.; Ballantyne, D. R.; Baloković, M.; Bauer, F. E.; Brandt, W. N.; Brightman, M.; Chen, C.-T. J.; Civano, F.; Comastri, A.; Del Moro, A.; Fuentes, C.; Harrison, F. A.; Marchesi, S.; Masini, A.; Mullaney, J. R.; Ricci, C.; Saez, C.; Tomsick, J. A.; Treister, E.; Walton, D. J.; Zappacosta, L.

    2017-09-01

    We identify sources with extremely hard X-ray spectra (I.e., with photon indices of {{Γ }}≲ 0.6) in the 13 deg2 NuSTAR serendipitous survey, to search for the most highly obscured active galactic nuclei (AGNs) detected at > 10 {keV}. Eight extreme NuSTAR sources are identified, and we use the NuSTAR data in combination with lower-energy X-ray observations (from Chandra, Swift XRT, and XMM-Newton) to characterize the broadband (0.5-24 keV) X-ray spectra. We find that all of the extreme sources are highly obscured AGNs, including three robust Compton-thick (CT; {N}{{H}}> 1.5× {10}24 cm-2) AGNs at low redshift (z< 0.1) and a likely CT AGN at higher redshift (z = 0.16). Most of the extreme sources would not have been identified as highly obscured based on the low-energy (< 10 keV) X-ray coverage alone. The multiwavelength properties (e.g., optical spectra and X-ray-mid-IR luminosity ratios) provide further support for the eight sources being significantly obscured. Correcting for absorption, the intrinsic rest-frame 10-40 keV luminosities of the extreme sources cover a broad range, from ≈ 5× {10}42 to 1045 erg s-1. The estimated number counts of CT AGNs in the NuSTAR serendipitous survey are in broad agreement with model expectations based on previous X-ray surveys, except for the lowest redshifts (z< 0.07), where we measure a high CT fraction of {f}{CT}{obs}={30}-12+16 % . For the small sample of CT AGNs, we find a high fraction of galaxy major mergers (50% ± 33%) compared to control samples of “normal” AGNs.

  4. Intrinsic magnetic properties of L1(0) FeNi obtained from meteorite NWA 6259

    Energy Technology Data Exchange (ETDEWEB)

    Poirier, E; Pinkerton, FE; Kubic, R; Mishra, RK; Bordeaux, N; Mubarok, A; Lewis, LH; Goldstein, JI; Skomski, R; Barmak, K

    2015-05-07

    FeNi having the tetragonal L1(0) crystal structure is a promising new rare-earth-free permanent magnet material. Laboratory synthesis is challenging, however, tetragonal L1(0) FeNi-the mineral "tetrataenite"-has been characterized using specimens found in nickel-iron meteorites. Most notably, the meteorite NWA 6259 recovered from Northwest Africa is 95 vol.% tetrataenite with a composition of 43 at.% Ni. Hysteresis loops were measured as a function of sample orientation on a specimen cut from NWA 6259 in order to rigorously deduce the intrinsic hard magnetic properties of its L1(0) phase. Electron backscatter diffraction showed that NWA 6259 is strongly textured, containing L1(0) grains oriented along any one of the three equivalent cubic directions of the parent fcc structure. The magnetic structure was modeled as a superposition of the three orthonormal uniaxial variants. By simultaneously fitting first-quadrant magnetization data for 13 different orientations of the sample with respect to the applied field direction, the intrinsic magnetic properties were estimated to be saturation magnetization 4 pi M-s = 14.7 kG and anisotropy field H-a = 14.4 kOe. The anisotropy constant K = 0.84 MJ/m(3) is somewhat smaller than the value K = 1.3 MJ/m(3) obtained by earlier researchers from nominally equiatomic FeNi prepared by neutron irradiation accompanied by annealing in a magnetic field, suggesting that higher Ni content (fewer Fe antisite defects) may improve the anisotropy. The fit also indicated that NWA 6259 contains one dominant variant (62% by volume), the remainder of the sample being a second variant, and the third variant being absent altogether. (C) 2015 AIP Publishing LLC.

  5. 3-10 keV and 0.1- to 2-MeV observations of four gamma-ray bursts

    International Nuclear Information System (INIS)

    Laros, J.G.; Evans, W.D.; Fenimore, E.E.; Klebesadel, R.W.; Shulman, S.; Fritz, G.

    1983-01-01

    Four catalogued γ-ray bursts that occurred between 79/3/7 and 79/7/31 have been observed over the 3 to 10 keV range by a joint NRL/Los Alamos experiment on the Air Force P78-1 satellite. The bursts were also well observed by members of the interplanetary network. In this paper we present hardness ratios, x-ray/γ-ray luminosity ratios, and time histories. The most significant results presented herein can be summarized as follows: (1) gamma-ray bursters can emit fairly strongly at x-ray energies near the time of the γ burst with L/sub x//L/sub γ/ approx. .02 (L/sub x/ approx. 10 37 ergs s -1 , 3 to 10 keV, assuming a distance of 1 kpc); (2) the centroid of the x-ray emission generally lags the γ-ray centroid, but there is also evidence for one or more types of x-ray precursor activity; (3) the γ-ray hardness ratios were not highly variable for these particular events. However, there is some evidence that the γ-ray spectra softened near the ends of the bursts when the x-ray/γ-ray ratios were high; (4) the x-ray/γ-ray power law number index during times of the strongest γ-ray emission ranged from 0.8 to approx. 1.1 for the four bursts; (5) the x-ray tail of GB790307 probably can be modeled as the cooling of hot plasma generated during the γ-ray burst. Simple versions of this model can be used to estimate various source parameters. These estimates imply a distance of a few hundred to a few thousand pc; (6) gamma-ray bursters probably do not produce events similar to classical x-ray bursts independently of the γ-ray emission

  6. Nustar Reveals an Intrinsically X-ray Weak Broad Absorption Line Quasar in the Ultraluminous Infrared Galaxy Markarian 231

    Science.gov (United States)

    Teng, Stacy H.; Brandt. W. N.; Harrison, F. A.; Luo, B.; Alexander, D. M.; Bauer, F. E.; Boggs, S. E.; Christensen, F. E.; Comastri, A.; Craig, W. W.; hide

    2014-01-01

    We present high-energy (3-30 keV) NuSTAR observations of the nearest quasar, the ultraluminous infrared galaxy (ULIRG) Markarian 231 (Mrk 231), supplemented with new and simultaneous low-energy (0.5-8 keV) data from Chandra. The source was detected, though at much fainter levels than previously reported, likely due to contamination in the large apertures of previous non-focusing hard X-ray telescopes. The full band (0.5-30 keV) X-ray spectrum suggests the active galactic nucleus (AGN) in Mrk 231 is absorbed by a patchy and Compton-thin N(sub H) approx. 1.2(sup +0.3) sub-0.3) x 10(exp 23) / sq cm) column. The intrinsic X-ray luminosity L(sub 0.5-30 Kev) approx. 1.0 x 10(exp 43) erg /s) is extremely weak relative to the bolometric luminosity where the 2-10 keV to bolometric luminosity ratio is approx. 0.03% compared to the typical values of 2-15%. Additionally, Mrk 231 has a low X-ray-to-optical power law slope alpha(sub 0X) approx. -1.7. It is a local example of a low-ionization broad absorption line (LoBAL) quasar that is intrinsically X-ray weak. The weak ionizing continuum may explain the lack of mid-infrared [O IV], [Ne V], and [Ne VI] fine-structure emission lines which are present in sources with otherwise similar AGN properties. We argue that the intrinsic X-ray weakness may be a result of the super-Eddington accretion occurring in the nucleus of this ULIRG, and may also be naturally related to the powerful wind event seen in Mrk 231, a merger remnant escaping from its dusty cocoon.

  7. Near-intrinsic energy resolution for 30–662 keV gamma rays in a high pressure xenon electroluminescent TPC

    International Nuclear Information System (INIS)

    Álvarez, V.; Borges, F.I.G.M.; Cárcel, S.; Castel, J.; Cebrián, S.; Cervera, A.; Conde, C.A.N.; Dafni, T.; Dias, T.H.V.T.; Díaz, J.

    2013-01-01

    We present the design, data and results from the NEXT prototype for Double Beta and Dark Matter (NEXT-DBDM) detector, a high-pressure gaseous natural xenon electroluminescent time projection chamber (TPC) that was built at the Lawrence Berkeley National Laboratory. It is a prototype of the planned NEXT-100 136 Xe neutrino-less double beta decay (0νββ) experiment with the main objectives of demonstrating near-intrinsic energy resolution at energies up to 662 keV and of optimizing the NEXT-100 detector design and operating parameters. Energy resolutions of ∼1% FWHM for 662 keV gamma rays were obtained at 10 and 15 atm and ∼5% FWHM for 30 keV fluorescence xenon X-rays. These results demonstrate that 0.5% FWHM resolutions for the 2459 keV hypothetical neutrino-less double beta decay peak are realizable. This energy resolution is a factor 7–20 better than that of the current leading 0νββ experiments using liquid xenon and thus represents a significant advancement. We present also first results from a track imaging system consisting of 64 silicon photo-multipliers recently installed in NEXT–DBDM that, along with the excellent energy resolution, demonstrates the key functionalities required for the NEXT-100 0νββ search

  8. Mass attenuation and mass energy absorption coefficients for 10 keV to 10 MeV photons; Coefficients d'attenuation massique et d'absorption massique en energie pour les photons de 10 keV a 10 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Joffre, H; Pages, L [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-07-01

    In this report are given the elements allowing the definition of the values of mass attenuation coefficients and mass energy absorption coefficients for some elements and mixtures, necessary for the study of tissue equivalent materials, for photons in the energy range 10 keV to 10 MeV. After a short reminding of the definitions of the two coefficients, follows, in table form, a compilation of these coefficients, as a function of energy, for simple elements, for certain mineral compounds, organic compounds, gases and particularly of soft tissues. (author) [French] Dans ce rapport, sont donnes les elements permettant de determiner les valeurs des coefficients d'attenuation massique et d'absorption massique en energie pour certains elements et melanges necessaires a l'etude des materiaux equivalents aux tissus pour les photons dans le domaine d'energie allant de 10 keV a 10 MeV. Apres un bref rappel des definitions des deux coefficients, suit, sous forme de tableaux, un recueil de ces coefficients, en fonction de l'energie, pour les elements simples, certains composes mineraux, composes organiques, gaz, et, particulierement, pour les tissus mous. (auteur)

  9. Formation of H(2s) atoms by excitation in 10-100 keV H+-H collisions

    International Nuclear Information System (INIS)

    Higgins, D.P.; Geddes, J.; Gilbody, H.B.

    1996-01-01

    Cross sections for 2s excitation of H atoms in 10-100 keV H + -H collisions have been determined using a modulated crossed-beam technique. The measurements have been based on observations of the Lyman alpha radiation emitted during electric-field-induced decay of the metastable H(2s) collision products. The results extend the range of the 5-26 keV cross sections measured by Morgan and co-workers to intermediate energies where theoretical predictions based on close-coupling methods are known to be strongly dependent on the choice of the expansion basis. The present cross sections pass through a broad maximum at about 40 keV. Over the range 5-100 keV the available experimental data exhibit an undulatory structure similar to that predicted by some close-coupling calculations but good quantitative agreement is very limited. Close-coupling calculations which employ large basis sets and include a large number of projectile states at the expense of target states are shown to agree less satisfactorily with experiment than those which include only the dominant 1s capture projectile channel. (Author)

  10. Measurement of high-energy (10–60 keV) x-ray spectral line widths with eV accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Seely, J. F., E-mail: seelyjf@gmail.com; Feldman, U. [Artep Inc., 2922 Excelsior Springs Court, Ellicott City, Maryland 21042 (United States); Glover, J. L.; Hudson, L. T.; Ralchenko, Y.; Henins, Albert [National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States); Pereira, N. [Ecopulse Inc., P. O. Box 528, Springfield, Virginia 22152 (United States); Di Stefano, C. A.; Kuranz, C. C.; Drake, R. P. [University of Michigan, Ann Arbor, Michigan 48109 (United States); Chen, Hui; Williams, G. J.; Park, J. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States)

    2014-11-15

    A high resolution crystal spectrometer utilizing a crystal in transmission geometry has been developed and experimentally optimized to measure the widths of emission lines in the 10–60 keV energy range with eV accuracy. The spectrometer achieves high spectral resolution by utilizing crystal planes with small lattice spacings (down to 2d = 0.099 nm), a large crystal bending radius and Rowland circle diameter (965 mm), and an image plate detector with high spatial resolution (60 μm in the case of the Fuji TR image plate). High resolution W L-shell and K-shell laboratory test spectra in the 10–60 keV range and Ho K-shell spectra near 47 keV recorded at the LLNL Titan laser facility are presented. The Ho K-shell spectra are the highest resolution hard x-ray spectra recorded from a solid target irradiated by a high-intensity laser.

  11. Experimental determination of L X-ray fluorescence cross sections for elements with 45 < Z < 50 at 10 keV

    Directory of Open Access Journals (Sweden)

    Edgardo Bonzi

    2014-02-01

    Full Text Available Synchrotron radiation at 10 keV was used to experimentally determine the Ll, L, LI, LII, LI and LII fluorescence cross sections for elements with 45 < Z < 50, as part of an ongoing investigation at low energies. The measured data were compared with calculated values obtained using coefficients from Scofield, Krause and Puri et al. Received: 19 December 2013, Accepted: 20 January 2014; Reviewed by: J. P. Marques, Departamento de Física, Centro de Física Atómica, Fac. de Ciências, Universidade de Lisboa, Portugal.; Edited by: P. Weck; DOI: http://dx.doi.org/10.4279/PIP.060001 Cite as: E V Bonzi, G B Grad, R A Barrea, Papers in Physics 6, 060001 (2014

  12. Intrinsic and Extrinsic Regulation of PD-L2 Expression in Oncogene-Driven Non-Small Cell Lung Cancer.

    Science.gov (United States)

    Shibahara, Daisuke; Tanaka, Kentaro; Iwama, Eiji; Kubo, Naoki; Ota, Keiichi; Azuma, Koichi; Harada, Taishi; Fujita, Jiro; Nakanishi, Yoichi; Okamoto, Isamu

    2018-03-27

    The interaction of programmed cell death ligand 2 (PD-L2) with programmed cell death 1 is implicated in tumor immune escape. The regulation of PD-L2 expression in tumor cells has remained unclear, however. We here examined intrinsic and extrinsic regulation of PD-L2 expression in NSCLC. PD-L2 expression was evaluated by reverse transcription and real-time polymerase chain reaction analysis and by flow cytometry. BEAS-2B cells stably expressing an activated mutant form of EGFR or the echinoderm microtubule associated protein like 4 (EML4)-ALK receptor tyrosine kinase fusion oncoprotein manifested increased expression of PD-L2 at both the mRNA and protein levels. Furthermore, treatment of NSCLC cell lines that harbor such driver oncogenes with corresponding EGFR or ALK tyrosine kinase inhibitors or depletion of EGFR or ALK by small interfering RNA transfection suppressed expression of PD-L2, demonstrating that activating EGFR mutations or echinoderm microtubule associated protein like 4 gene (EML4)-ALK receptor tyrosine kinase gene (ALK) fusion intrinsically induce PD-L2 expression. We also found that interferon gamma (IFN-γ) extrinsically induced expression of PD-L2 through signal transducer and activator of transcription 1 signaling in NSCLC cells. Oncogene-driven expression of PD-L2 in NSCLC cells was inhibited by knockdown of the transcription factors signal transducer and activator of transcription 3 (STAT3) or c-FOS. IFN-γ also activated STAT3 and c-FOS, suggesting that these proteins may also contribute to the extrinsic induction of PD-L2 expression. Expression of PD-L2 is induced intrinsically by activating EGFR mutations or EML4-ALK fusion and extrinsically by IFN-γ, with STAT3 and c-FOS possibly contributing to both intrinsic and extrinsic pathways. Our results thus provide insight into the complexity of tumor immune escape in NSCLC. Copyright © 2018 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.

  13. The detection of hard x-rays (10-140 KeV) by channel plate electron multipliers

    International Nuclear Information System (INIS)

    Bateman, J.E.

    1976-12-01

    Results are presented indicating that hard X-rays in the energy range 10 to 50 keV can be detected with good efficiency (5 to 10%) in channel plate electron multipliers (CPEM). From 50 keV to 140 keV the detection efficiency lies in the range 1 to 2%. A simple physical model is developed which indicates that not only can good detection efficiency be obtained but that very good X-ray imaging is possible. The model predicts that with further development, a wideband, hard X-ray detector can be realised with a detection efficiency in the range 5 to 20% and spatial response better than 10 lp/mm in the energy range 10 to 140 keV. (author)

  14. Ionization cross sections of the Au L subshells by electron impact from the L3 threshold to 100 keV

    Science.gov (United States)

    Barros, Suelen F.; Vanin, Vito R.; Maidana, Nora L.; Martins, Marcos N.; García-Alvarez, Juan A.; Santos, Osvaldo C. B.; Rodrigues, Cleber L.; Koskinas, Marina F.; Fernández-Varea, José M.

    2018-01-01

    We measured the cross sections for Au Lα, Lβ, Lγ, Lℓ and Lη x-ray production by the impact of electrons with energies from the L3 threshold to 100 keV using a thin Au film whose mass thickness was determined by Rutherford Backscattering Spectrometry. The x-ray spectra were acquired with a Si drift detector, which allowed to separate the components of the Lγ multiplet lines. The measured Lα, Lβ, {{L}}{γ }1, L{γ }{2,3,6}, {{L}}{γ }{4,4\\prime }, {{L}}{γ }5, {{L}}{\\ell } and Lη x-ray production cross sections were then employed to derive Au L1, L2 and L3 subshell ionization cross sections with relative uncertainties of 8%, 7% and 7%, respectively; these figures include the uncertainties in the atomic relaxation parameters. The correction for the increase in electron path length inside the Au film was estimated by means of Monte Carlo simulations. The experimental ionization cross sections are about 10% above the state-of-the-art distorted-wave calculations.

  15. The NuSTAR Extragalactic Survey: First Direct Measurements of the Greater Than Or Similar To 10 Kev X-Ray Luminosity Function For Active Galactic Nuclei At z > 0.1

    DEFF Research Database (Denmark)

    Aird, J.; Alexander, D. M.; Ballantyne, D. R.

    2015-01-01

    We present the first direct measurements of the rest-frame 10-40 keV X-ray luminosity function (XLF) of active galactic nuclei (AGNs) based on a sample of 94 sources at 0.1 ... program. Our results are consistent with the strong evolution of the AGN population seen in prior, lower-energy studies of the XLF. However, different models of the intrinsic distribution of absorption, which are used to correct for selection biases, give significantly different predictions for the total...... component (with a relative normalization of R ∼ 2 at all luminosities) can bring extrapolations of the XLF from 2-10 keV into agreement with our NuSTAR sample. Ultimately, X-ray spectral analysis of the NuSTAR sources is required to break this degeneracy between the distribution of absorbing column...

  16. Single-electron capture for 2-8 keV incident energy and direct scattering at 6 keV in He2+-He collisions

    International Nuclear Information System (INIS)

    Bordenave-Montesquieu, D.; Dagnac, R.

    1992-01-01

    We studied the single-electron capture as well as the direct processes occurring when a He 2+ ion is scattered by a He target. Doubly differential cross sections were measured for single-electron capture with a collision energy ranging from 2 to 8 keV and a scattering angle varying from 10' to 3 o 30' (laboratory frame). Single-electron capture into excited states of He + was found to be the dominant process, confirming a previous experimental study. Elastic scattering and ionization differential cross sections were measured for E = 6 keV. (Author)

  17. Intrinsic Properties of Fe-Substituted L1(0) Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Manchanda, P; Kumar, P; Kashyap, A; Lucis, MJ; Shield, JE; Mubarok, A; Goldstein, JI; Constantinides, S; Barmak, K; Lewis, LH; Sellmyer, DJ; Skomski, R

    2013-10-01

    First-principle supercell calculations are used to determine how 3d elemental additions, especially Fe additions, modify the magnetization, exchange and anisotropy of L1(0)-ordered ferromagnets. Calculations are performed using the VASP code and partially involve configurational averaging over site disorder. Three isostructural systems are investigated: Fe-Co-Pt, Mn-Al-Fe, and transition metal-doped Fe-Ni. In all three systems the iron strongly influences the magnetic properties of these compounds, but the specific effect depends on the host. In CoPt(Fe) iron enhances the magnetization, with subtle changes in the magnetic moments that depend on the distribution of the Fe and Co atoms. The addition of Fe to MnAl is detrimental to the magnetization, because it creates antiferromagnetic exchange interactions, but it enhances the magnetic anisotropy. The replacement of 50% of Mn by Fe in MnFeAl2 enhances the anisotropy from 1.77 to 2.5 MJ/m(3). Further, the substitution of light 3d elements such as Ti, V, Cr into L1(0)-ordered FeNi is shown to substantially reduce the magnetization.

  18. POLARIZED-LIGHT EMISSION IN KEV HE2++NA(3S) COLLISIONS

    NARCIS (Netherlands)

    BODUCH, P; VANBUCHEM, J; BLIEK, FW; HOEKSTRA, R; MORGENSTERN, R; OLSON, RE

    1995-01-01

    We investigated l and m-distributions of He II (n = 4) states formed during 2-13.3 keV amu(-1) He2+ + Na(3s) collisions by measuring profiles and the linear polarization of the He II (4 --> 3) emission. We found that at these energies capture into He+(4f) dominates over capture into other He+(4l)

  19. 7 keV sterile neutrino dark matter from split flavor mechanism

    International Nuclear Information System (INIS)

    Ishida, Hiroyuki; Takahashi, Fuminobu; Tokyo Univ., Kashiwa

    2014-02-01

    The recently discovered X-ray line at about 3.5 keV can be explained by sterile neutrino dark matter with mass, m s ≅ 7 keV, and the mixing, sin 2 2θ∝10 -10 . Such sterile neutrino is more long-lived than estimated based on the seesaw formula, which strongly suggests an extra flavor structure in the seesaw sector. We show that one can explain both the small mass and the longevity based on the split flavor mechanism where the breaking of flavor symmetry is tied to the breaking of the B-L symmetry. In a supersymmetric case we find that the 7 keV sterile neutrino implies the gravitino mass about 100 TeV.

  20. Secondary ion emission from metal surfaces bombarded by 0.5-10 keV protons and hydrogens

    International Nuclear Information System (INIS)

    Kitamura, Akira; Yano, Syukuro

    1978-01-01

    Secondary ion emission coefficients by bombardment of 0.5 - 10 keV protons K 11 and atomic hydrogens K 01 on copper, stainless steel, molybdenum and evaporated gold surfaces have been measured in a moderate vacuum. Results are summarized as follows; 1) There is no significant difference between K 11 and K 01 . 2) Differences in K 11 and K 11 between different samples of the same material and between the sample before baking-out and the same sample after baking-out are of the order of several tens of percent. 3) The incident particle energy E sub(max) at which K 11 and K 01 have the maximum value lies in the keV region, and increases with the target mass. According to the fact that E sub(max) differs substantially from the energy at which the elastic stopping power has the maximum value, a characteristic length l is introduced and calculated to be of the order of hundreds of A; the factor exp (-x/l) represents the degree of contribution of collision at depth x to K 11 or K 01 . (author)

  1. Differences in the neutralization of 2.4--10 keV Ne+ scattered from the Cu and Au atoms of an alloy surface

    International Nuclear Information System (INIS)

    Buck, T.M.; Wallace, W.E.; Baragiola, R.A.; Wheatley, G.H.; Rothman, J.B.; Gorte, R.J.; Tittensor, J.G.

    1993-01-01

    The neutralization behavior of low-energy Ne + ions scattered from a compositionally ordered Cu 3 Au(100) surface has been studied over a range of incident energy E 0 from 2.4 to 10 keV. Ion fractions of Ne scattered from Cu atoms in the first, or first two, atom layers exhibited a sharp increase setting in at an E 0 of 4--5 keV, reaching 70% at 10 keV for first-layer scattering. Inelastic energy losses, up to 130 eV, and Auger electron emission from Ne scattered from Cu, were also observed at incident energies above 4 keV. Ne scattered from the Au atoms on the same Cu 3 Au(100) surface showed only the usual velocity-dependent Auger and resonance neutralization. An explanation of the Cu results is given in terms of Ne 2s vacancy creation during the close collision of Ne, which is neutralized on the inward path, followed by autoionization on the outward path after scattering into the vacuum. Conversely, Ne cannot approach Au closely enough to form an appropriate inner-shell vacancy. This is due to the higher Coulombic repulsion created by the greater charge of the Au nucleus

  2. A Study of the 190 keV Transition in {sup 141}La

    Energy Technology Data Exchange (ETDEWEB)

    Berg, V; Hoeglund, Aa [Inst. of Physics, Univ. of Stockholm (Sweden); [AB Atome nergi, Nykoping (Sweden); Fogelberg, B [Inst. of Physics, Uppsala Univ. (Sweden)

    1970-05-15

    The gamma-ray spectrum from the decay of 18 min 141 Ba has been studied. Seventeen transitions were found below 900 keV, with energies and (intensities) as follows: 112.9{+-}0.2(3.0), 163.1{+-}0.3 (1.0), 165.7{+-}0.4(0.7), 180.5{+-}0.2(0.9), 190.3{+-}0.1(100), 276.9{+-}0.1 (52.2), 304.2{+-}0.1(55.8), 343.6{+-}0.1(30.8), 364.4{+-}0.6(1.6), 389.7{+-}0.2(2.8), 457.7{+-}0.2(10.4), 462.3{+-}0.2(10.5), 467.3{+-}0.1(11.4), 625.1{+-}0.2(6.1), 647.9{+-}0.2(10.7), 739.1{+-}0.3(8.7), 876.5{+-}0.3(6.7). K- and L-shell conversion coefficients have been measured for the 190. 3 keV transition, yielding a multipolarity of M1 + < 8 % E2. Half-life measurements using delayed coincidence technique have given the following results: T{sub 1/2} (190 keV level) = 1.27 {sup +0.06}{sub -0.10} ns, T{sub 1/2} (304 keV level) < 200 ps, T{sub 1/2} (467 keV level) < 120 ps. A level scheme of {sup 141}La has been constructed, and the spin-parity assignments of the ground state and first excited state are discussed in terms of the shell model.

  3. 7 keV sterile neutrino dark matter from split flavor mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Ishida, Hiroyuki [Tohoku Univ., Sendai (Japan). Dept. of Physics; Jeong, Kwang Sik [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Takahashi, Fuminobu [Tohoku Univ., Sendai (Japan). Dept. of Physics; Tokyo Univ., Kashiwa (Japan). Kavli IPMU, TODIAS

    2014-02-15

    The recently discovered X-ray line at about 3.5 keV can be explained by sterile neutrino dark matter with mass, m{sub s}≅ 7 keV, and the mixing, sin{sup 2}2θ∝10{sup -10}. Such sterile neutrino is more long-lived than estimated based on the seesaw formula, which strongly suggests an extra flavor structure in the seesaw sector. We show that one can explain both the small mass and the longevity based on the split flavor mechanism where the breaking of flavor symmetry is tied to the breaking of the B-L symmetry. In a supersymmetric case we find that the 7 keV sterile neutrino implies the gravitino mass about 100 TeV.

  4. Single-electron capture for 2-8 keV incident energy and direct scattering at 6 keV in He[sup 2+]-He collisions

    Energy Technology Data Exchange (ETDEWEB)

    Bordenave-Montesquieu, D.; Dagnac, R. (Toulouse-3 Univ., 31 (France). Centre de Physique Atomique)

    1992-06-14

    We studied the single-electron capture as well as the direct processes occurring when a He[sup 2+] ion is scattered by a He target. Doubly differential cross sections were measured for single-electron capture with a collision energy ranging from 2 to 8 keV and a scattering angle varying from 10' to 3[sup o]30' (laboratory frame). Single-electron capture into excited states of He[sup +] was found to be the dominant process, confirming a previous experimental study. Elastic scattering and ionization differential cross sections were measured for E = 6 keV. (Author).

  5. Measurements of L shell X-ray yields of thick Ag target by 6–29 keV electron impact

    International Nuclear Information System (INIS)

    Zhao, J.L.; Tian, L.X.; Li, X.L.; An, Z.; Zhu, J.J.; Liu, M.T.

    2015-01-01

    In this paper, the L shell X-ray yields for a thick Ag target have been measured at incident electron energies of 6–29 keV. The experimental values are compared with the Monte Carlo simulation results that are obtained by using the PENELOPE code, in which the inner-shell ionization cross sections by electron impact calculated in the theoretical frame of distorted wave Born approximation are used. The experimental and simulation values are in agreement with ∼10% difference. Meanwhile, the L shell X-ray production cross sections are also obtained based on the measured L shell X-ray yields for a thick Ag target in this paper, and are compared with other experimental Ag L shell X-ray production cross section data by electron and positron impact measured previously and some theoretical models. Some factors that could affect these comparisons are also discussed in this paper. - Highlights: • We measured L shell X-ray yields of thick Ag target by 6–29 keV electrons. • Our measured X-ray yields are in good agreement with the MC results with ∼10%. • L shell production cross sections are obtained based on the measured X-ray yields. • L shell production cross sections obtained are in good agreement with theories

  6. A model for Simpson's 17 keV neutrino

    International Nuclear Information System (INIS)

    Rajpoot, S.

    1992-01-01

    Recent studies of β-decay spectra seem to confirm Simpson's earlier findings that the electron neutrinos contain a small (1%) admixture of a 17 keV Dirac neutrino. In this paper an unconventional model with SU(2) L x SU(2) R x U(1) B-1 gauge interactions is presented in which all neutrinos are Dirac particles. Electron and muon neutrinos acquire seesaw Dirac masses of order 10 -3 eV for the MSW solution for the solar neutrino problem. The τ neutrino is identified as Simpson's 17 keV neutrino. Constraints coming from cosmology and particle physics are shown to be satisfied

  7. Intrinsic magnetic properties of L10 FeNi obtained from meteorite NWA 6259

    International Nuclear Information System (INIS)

    Poirier, Eric; Pinkerton, Frederick E.; Kubic, Robert; Mishra, Raja K.; Bordeaux, Nina; Lewis, Laura H.; Mubarok, Arif; Goldstein, Joseph I.; Skomski, Ralph; Barmak, Katayun

    2015-01-01

    FeNi having the tetragonal L1 0 crystal structure is a promising new rare-earth-free permanent magnet material. Laboratory synthesis is challenging, however, tetragonal L1 0 FeNi—the mineral “tetrataenite”—has been characterized using specimens found in nickel-iron meteorites. Most notably, the meteorite NWA 6259 recovered from Northwest Africa is 95 vol. % tetrataenite with a composition of 43 at. % Ni. Hysteresis loops were measured as a function of sample orientation on a specimen cut from NWA 6259 in order to rigorously deduce the intrinsic hard magnetic properties of its L1 0 phase. Electron backscatter diffraction showed that NWA 6259 is strongly textured, containing L1 0 grains oriented along any one of the three equivalent cubic directions of the parent fcc structure. The magnetic structure was modeled as a superposition of the three orthonormal uniaxial variants. By simultaneously fitting first-quadrant magnetization data for 13 different orientations of the sample with respect to the applied field direction, the intrinsic magnetic properties were estimated to be saturation magnetization 4πM s  = 14.7 kG and anisotropy field H a  = 14.4 kOe. The anisotropy constant K = 0.84 MJ/m 3 is somewhat smaller than the value K = 1.3 MJ/m 3 obtained by earlier researchers from nominally equiatomic FeNi prepared by neutron irradiation accompanied by annealing in a magnetic field, suggesting that higher Ni content (fewer Fe antisite defects) may improve the anisotropy. The fit also indicated that NWA 6259 contains one dominant variant (62% by volume), the remainder of the sample being a second variant, and the third variant being absent altogether

  8. THE RELATIONSHIP BETWEEN X-RAY LUMINOSITY AND MAJOR FLARE LAUNCHING IN GRS 1915+105

    International Nuclear Information System (INIS)

    Punsly, Brian; Rodriguez, Jérôme

    2013-01-01

    We perform the most detailed analysis to date of the X-ray state of the Galactic black hole candidate GRS 1915+105 just prior to (0-4 hr) and during the brief (1-7 hr) ejection of major (superluminal) radio flares. A very strong model independent correlation is found between the 1.2 keV-12 keV X-ray flux 0-4 hr before flare ejections with the peak optically thin 2.3 GHz emission of the flares. This suggests a direct physical connection between the energy in the ejection and the luminosity of the accretion flow preceding the ejection. In order to quantify this concept, we develop techniques to estimate the intrinsic (unabsorbed) X-ray luminosity, L intrinsic , from RXTE All Sky Monitor data and to implement known methods to estimate the time-averaged power required to launch the radio emitting plasmoids, Q (sometimes called jet power). We find that the distribution of intrinsic luminosity from 1.2 keV-50 keV, L intrinsic (1.2-50), is systematically elevated just before ejections compared to arbitrary times when there are no major ejections. The estimated Q is strongly correlated with L intrinsic (1.2-50) 0-4 hr before the ejection, the increase in L intrinsic (1.2-50) in the hours preceding the ejection and the time-averaged L intrinsic (1.2-50) during the flare rise. Furthermore, the total time-averaged power during the ejection (Q + the time average of L intrinsic (1.2-50) during ejection) is strongly correlated with L intrinsic (1.2-50) just before launch with near equality if the distance to the source is ≈10.5 kpc.

  9. Weak hard X-ray emission from broad absorption line quasars: evidence for intrinsic X-ray weakness

    International Nuclear Information System (INIS)

    Luo, B.; Brandt, W. N.; Scott, A. E.; Alexander, D. M.; Gandhi, P.; Stern, D.; Teng, S. H.; Arévalo, P.; Bauer, F. E.; Boggs, S. E.; Craig, W. W.; Christensen, F. E.; Comastri, A.; Farrah, D.; Hailey, C. J.; Harrison, F. A.; Koss, M.; Ogle, P.; Puccetti, S.; Saez, C.

    2014-01-01

    We report NuSTAR observations of a sample of six X-ray weak broad absorption line (BAL) quasars. These targets, at z = 0.148-1.223, are among the optically brightest and most luminous BAL quasars known at z < 1.3. However, their rest-frame ≈2 keV luminosities are 14 to >330 times weaker than expected for typical quasars. Our results from a pilot NuSTAR study of two low-redshift BAL quasars, a Chandra stacking analysis of a sample of high-redshift BAL quasars, and a NuSTAR spectral analysis of the local BAL quasar Mrk 231 have already suggested the existence of intrinsically X-ray weak BAL quasars, i.e., quasars not emitting X-rays at the level expected from their optical/UV emission. The aim of the current program is to extend the search for such extraordinary objects. Three of the six new targets are weakly detected by NuSTAR with ≲ 45 counts in the 3-24 keV band, and the other three are not detected. The hard X-ray (8-24 keV) weakness observed by NuSTAR requires Compton-thick absorption if these objects have nominal underlying X-ray emission. However, a soft stacked effective photon index (Γ eff ≈ 1.8) for this sample disfavors Compton-thick absorption in general. The uniform hard X-ray weakness observed by NuSTAR for this and the pilot samples selected with <10 keV weakness also suggests that the X-ray weakness is intrinsic in at least some of the targets. We conclude that the NuSTAR observations have likely discovered a significant population (≳ 33%) of intrinsically X-ray weak objects among the BAL quasars with significantly weak <10 keV emission. We suggest that intrinsically X-ray weak quasars might be preferentially observed as BAL quasars.

  10. WE-E-BRE-08: Impact of IUdR in Rat 9L Glioma Cell Survival for 25–35 KeV Photo-Activated Auger Electron Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez, D; Hogstrom, K [Louisiana State University, Baton Rouge, LA (United States); Mary Bird Perkins Cancer Center, Baton Rouge, LA (United States); Brown, T; Dugas, J; Varnes, M [Mary Bird Perkins Cancer Center, Baton Rouge, LA (United States); Matthews, K [Louisiana State University, Baton Rouge, LA (United States)

    2014-06-15

    Purpose: To determine the biological effect from Auger electrons with 9% and 18% iododeoxyuridine (IUdR) incorporated into the DNA of rat 9L glioma cells at photon energies above and below the K-edge of iodine (33.2 keV). Methods: Rat 9L glioma cell survival versus dose curves with 0%, 9%, and 18% thymidine replacement with IUdR were measured using four irradiation energies (4 MV x-rays; monochromatic 35, 30, and 25 keV synchrotron photons). For each of 11 conditions (Energy, %IUdR) survival curves were fit to the data (826 cell cultures) using the linear-quadratic model. The ratio of doses resulting in 10% survival gave sensitization enhancement ratios (SER10) from which contributions due to linear-energy transfer (LET), radiosensitization (RS), and Auger effect (AE) were extracted. Results: At 35, 30, and 25 keV, SER10,LET values were 1.08±0.03, 1.22±0.02, and 1.37±0.02, respectively. At 4 MV SER10,RS values for 9% and 18% IUdR were 1.28±0.02 and 1.40±0.02, respectively. Assuming LET effects are independent of %IUdR and radiosensitization effects are independent of energy, SER10,AE values for 18% IUdR at 35, 30, and 25 keV were 1.35±0.05, 1.06±0.03, and 0.98±0.03, respectively; values for 9% IUdR at 35 and 25 keV were 1.01±0.04 and 0.82±0.02, respectively. Conclusion: For 18% IUdR the radiosensitization effect of 1.40 and the Auger effect of 1.35 at 35 keV are equally important to the combined effect of 1.90. No measureable Auger effect was observed for energies below the K-edge at 20 and 25 keV, as expected. The insignificant Auger effect at 9% IUdR was not expected. Additional data (40–70 keV) and radiobiological modeling are being acquired to better understand the energy dependence of Auger electron therapy with IUdR. Funding support in part by the National Science Foundation Graduate Research Fellowship Program and in part by Contract No. W81XWH-10-1-0005 awarded by the U.S. Army Research Acquisition Activity. This paper does not necessarily

  11. Bragg concentrators for hard (> 10keV) x-ray astronomy: Status report

    DEFF Research Database (Denmark)

    Pareschi, G.; Frontera, F.; Pasqualini, G.

    1997-01-01

    The use of focusing telescopes in hard X-ray (E > 10 keV) astronomy will provide better flux sensitivity and imaging performances with respect to the direct-viewing detectors, utilized until now. We present recent results obtained from our group regarding the possible use of Bragg-diffraction tec......The use of focusing telescopes in hard X-ray (E > 10 keV) astronomy will provide better flux sensitivity and imaging performances with respect to the direct-viewing detectors, utilized until now. We present recent results obtained from our group regarding the possible use of Bragg...

  12. Study of vacancy decays in the L-shell photoionization of barium in the excitation energy range of 5.6-30 keV: from L{sub 2} edge to energy high above the thresholds of double L-vacancy production

    Energy Technology Data Exchange (ETDEWEB)

    Zou, Y [Key Laboratory of Applied Ion Beam Physics (Chinese Educational Ministry), Fudan University, Shanghai 200433 (China); Oura, M [RIKEN Spring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); Hutton, R [Lund Observatory, SE-221 00 Lund (Sweden); Yamaoka, H [RIKEN Spring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); Takeshima, N [Department of Chemistry and Materials Technology, Kyoto Institute of Technology, Matsugasaki, Sakyo-ku, Kyoto 606-8585 (Japan); Takahiro, K [Department of Chemistry and Materials Technology, Kyoto Institute of Technology, Matsugasaki, Sakyo-ku, Kyoto 606-8585 (Japan); Kawatsura, K [Department of Chemistry and Materials Technology, Kyoto Institute of Technology, Matsugasaki, Sakyo-ku, Kyoto 606-8585 (Japan); Mukoyama, T [Kansai Gaidai University, 16-1 Nakamiyahigashino-cho, Hirakata, Osaka 573-1001 (Japan)

    2006-11-28

    Photoinduced Ba L x-rays were measured, in the excitation energy range of 5.6-30 keV, by using high-brilliance undulator radiation. The obtained intensity ratios, the excitation-energy independent L{beta}{sub 4}/L{beta}{sub 3}, L{eta}/L{beta}{sub 1}, L{iota}/L{alpha}{sub 1,2}, L{beta}{sub 6}/L{alpha}{sub 1,2} and L{beta}{sub 2,15}/L{alpha}{sub 1,2} as well as the excitation-energy dependent L{beta}{sub 1}/L{alpha}{sub 1,2}, L{beta}{sub 3}/L{alpha}{sub 1,2} and L{beta}{sub 3}/L{beta}{sub 1}, were compared with theoretical calculations, in which the calculations were performed by applying various subsets of the L subshell fluorescence yields and Coster-Kronig yields. Deviations of the theoretical calculations from the experimental results call on improvements in theory for the emission rates. We have also surveyed the L{alpha}{sub 1,2} related x-ray hypersatellite lines in the photoinduced Ba L x-ray spectrum.

  13. Cross section for induced L X-ray emission by protons of energy <400 keV

    International Nuclear Information System (INIS)

    Mohan, Harsh; Jain, Arvind Kumar; Kaur, Mandeep; Singh, Parjit S.; Sharma, Sunita

    2014-01-01

    In performing ion beam analysis, cross section for induced L X-ray emission plays a crucial role. There are different approaches by which these can be found experimentally or can be calculated theoretically based on various models. L X-ray production cross sections for Bi with protons in the energy range 260–400 keV at the interval of 20 keV are measured. These are compared with calculations obtained on the basis of current prevailing theories ECPSSR and ECPSSR-UA. Their importance in understanding this phenomenon and existing arguments in this regard will be highlighted

  14. Measurement of L-shell photoelectric cross sections in high Z elements at 37 and 74 keV

    Energy Technology Data Exchange (ETDEWEB)

    Allawadhi, K L; Ghumman, B S; Sood, B S [Punjabi Univ., Patiala (India). Nuclear Science Labs.

    1977-05-01

    L-shell photoelectric cross section measurements have been made at 36.818 and 74.409 keV for four elements in the range 81<=Z<=92. The measurements at 74.409 keV are found to agree with theory, within experimental uncertainties, but the experimental values at 36.818 keV are found to be higher than the theoretical predictions. The possible reasons for the observed discrepancy are discussed.

  15. Isothermal annealing of silicon implanted with 50 keV 10B ions

    International Nuclear Information System (INIS)

    Weidner, B.; Zaschke, G.

    1974-01-01

    Isothermal annealing characteristics of silicon implanted with boron were measured and compared with calculated results. Implantation was performed with 50 keV 10 B ions in the dose range of 7.5 x 10 12 cm -2 to 2.0 x 10 15 cm -2 . Annealing temperatures ranged from 700 to 900 0 C. Maximum annealing time was 10 4 minutes. Annealing time strongly increases with increasing dose and decreasing temperature. Assuming that there is only one activation energy the isothermal annealing curves of constant dose and different temperatures were combined to a reduced annealing curve and the reduced isothermal annealing curve calculated. Starting from first order kinetics, considering the doping profile of boron in silicon and assuming a depth-dependent decay constant the experimentally determined annealing curves could be easily described over the total dose and time range

  16. Static and time-resolved 10-1000 keV x-ray imaging detector options for NIF

    International Nuclear Information System (INIS)

    Landen, O.L.; Bell, P.M.; McDonald, J.W.; Park, H.-S.; Weber, F.; Moody, J.D.; Lowry, M.E.; Stewart, R.E.

    2004-01-01

    High energy (>10 keV) x-ray self-emission imaging and radiography will be essential components of many NIF high energy density physics experiments. In preparation for such experiments, we have evaluated the pros and cons of various static [x-ray film, bare charge-coupled device (CCD), and scintillator + CCD] and time-resolved (streaked and gated) 10-1000 keV detectors

  17. Multilayer optics for monochromatic high-resolution X-ray imaging diagnostic in a broad photon energy range from 2 keV to 22 keV

    Science.gov (United States)

    Troussel, Ph.; Dennetiere, D.; Maroni, R.; Høghøj, P.; Hedacq, S.; Cibik, L.; Krumrey, M.

    2014-12-01

    The "Commissariat à l'énergie atomique et aux énergies alternatives" (CEA) studies and designs advanced X-ray diagnostics to probe dense plasmas produced at the future Laser MegaJoule (LMJ) facility. Mainly for X-ray imaging with high spatial resolution, different types of multilayer mirrors were developed to provide broadband X-ray reflectance at grazing incidence. These coatings are deposited on two toroidal mirror substrates that are then mounted into a Wolter-type geometry (working at a grazing angle of 0.45°) to realize an X-ray microscope. Non-periodic (depth graded) W/Si multilayer can be used in the broad photon energy range from 2 keV to 22 keV. A third flat mirror can be added for the spectral selection of the microscope. This mirror is coated with a Mo/Si multilayer for which the d-spacing varies in the longitudinal direction to satisfy the Bragg condition within the angular acceptance of the microscope and also to compensate the angular dispersion due to the field of the microscope. We present a study of such a so-called Göbel mirror which was optimized for photon energy of 10.35 keV. The three mirrors were coated using magnetron sputtering technology by Xenocs SA. The reflectance in the entire photon energy range was determined in the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the synchrotron radiation facility BESSY II in Berlin.

  18. Photon-induced L X-ray production differential cross sections in thorium at 22.6 keV

    International Nuclear Information System (INIS)

    Puri, Sanjiv; Mehta, D.; Shahi, J.S.; Garg, M.L.; Singh, Nirmal; Trehan, P.N.

    1999-01-01

    The Ll, Lα, Lβ 2,4 , Lβ 1,3 and Lγ 1,5 X-ray production differential cross sections in 90 Th have been measured at 22.6 keV incident photon energy in an angular range 50-130 deg. The measurements were performed using a 109 Cd annular-source and a Si(Li) detector. The measured differential cross sections for various L X-rays are found to be angle-independent within experimental error. This is contrary to the strong angular-dependence of photon-induced Ll and Lα X-ray production cross sections as reported by Kahlon et al. (K.S. Kahlon, H.S. Aulakh, N. Singh, R. Mittal, K.L. Allawadhi, B.S. Sood, Phys. Rev. A 43 (1991) 1455) and Ertugrul (M. Ertugrul, Nucl. Instr. and Meth. B 119 (1996) 345). Integral cross sections for production of Ll, Lα, Lη, Lβ 6 , Lβ 2,4 , Lβ 1,3 , Lβ 9,10 , Lγ 1,5 and total Lγ X-rays are also deduced and are found to be in good agreement with those calculated using reliable theoretical values of the L i (i=1, 2, 3) subshell photoionisation cross sections, fluorescence yields, X-ray emission rates and Coster-Kronig transition probabilities

  19. Calibration of a dePangher long counter from 2 keV to 19 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Slaughter, D R; Rueppel, D W [California Univ., Livermore (USA). Lawrence Livermore Lab.

    1977-09-01

    The authors have measured the sensitivity of a dePangher precision long counter (PLC) relative to /sup 7/Li(p,n), T(p,n), and T(d,n) differential cross sections over the neutron energy range 10 keV-19 MeV. Absolute sensitivity at 2 keV is also measured, using a scandium filtered beam at a reactor. Results obtained with errors in the range 5-30% are consistent with the assumption of a nearly constant sensitivity over the range 2 keV-6 MeV, but exhibit a reduction above 12 MeV.

  20. Searching for the 3.5 keV Line in the Deep Fields with Chandra: The 10 Ms Observations

    Science.gov (United States)

    Cappelluti, Nico; Bulbul, Esra; Foster, Adam; Natarajan, Priyamvada; Urry, Megan C.; Bautz, Mark W.; Civano, Francesca; Miller, Eric; Smith, Randall K.

    2018-02-01

    We report a systematic search for an emission line around 3.5 keV in the spectrum of the cosmic X-ray background using a total of ∼10 Ms Chandra observations toward the COSMOS Legacy and Extended Chandra Deep Field South survey fields. We find marginal evidence of a feature at an energy of ∼3.51 keV with a significance of 2.5–3σ, depending on the choice of statistical treatment. The line intensity is best fit at (8.8 ± 2.9) × 10‑7 ph cm‑2 s‑1 when using a simple Δχ 2 or {10.2}-0.4+0.2× {10}-7 ph cm‑2 s‑1 when Markov chain Monte Carlo is used. Based on our knowledge of Chandra and the reported detection of the line by other instruments, an instrumental origin for the line remains unlikely. We cannot, however, rule out a statistical fluctuation, and in that case our results provide a 3σ upper limit at 1.85 × 10‑6 ph cm‑2 s‑1. We discuss the interpretation of this observed line in terms of the iron line background, S XVI charge exchange, as well as potentially being from sterile neutrino decay. We note that our detection is consistent with previous measurements of this line toward the Galactic center and can be modeled as the result of sterile neutrino decay from the Milky Way for the dark matter distribution modeled as a Navarro–Frenk–White profile. For this case, we estimate a mass m ν ∼ 7.01 keV and a mixing angle sin2(2θ) = (0.83–2.75) × 1010. These derived values are in agreement with independent estimates from galaxy clusters, the Galactic center, and M31.

  1. Energy reflection coefficient for H+ ions at energies between 10 and 80 keV

    International Nuclear Information System (INIS)

    Chen, C.K.; Bohdansky, J.; Eckstein, W.; Robinson, M.T.

    1984-04-01

    The energy reflection coefficient for H + ions at energies between 10 keV and 80 keV was determined by experiments and by computer calculations. Measurements were made with graphite, Al, Cu, Mo and W. targets. The angle of ion incidence was restricted to 85 0 , 78 0 and 70 0 measured from the surface normal. Calculated data were obtained by two different Monte Carlo computer programs (MARLOWE, TRIM). It was found that both the calculated and the measured data scale with the parameter epsilon cos 2 α, where epsilon is Lindhard's reduced energy and α the angle of incidence for the ions. The measured values are smaller than those calculated. This can be explained by surface roughness which developed during the ion irradiation

  2. 10 CFR 2.1200 - Scope of subpart L.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Scope of subpart L. 2.1200 Section 2.1200 Energy NUCLEAR... Hearing Procedures for NRC Adjudications § 2.1200 Scope of subpart L. The provisions of this subpart... and request the application of Subpart L procedures, and proceedings for the direct or indirect...

  3. Contribution to the study of nuclear structure using neutron total cross-section measurements between 400 and 1200 keV: isolated resonances and intermediate structure; Contribution a l'etude de la structure nucleaire par des mesures de sections efficaces neutroniques entre 400 keV et 1200 keV. Resonances isolees et structure intermediaire

    Energy Technology Data Exchange (ETDEWEB)

    Cabe, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-06-15

    The neutron total cross sections have been measured over the energy range 400 keV - 1200 keV for fluorine, aluminium, silicon, phosphorus, vanadium, chromium, manganese, iron, nickel, cobalt and lead with an energy spread of 3 keV. The neutrons were produced by the T (p,n) {sup 3}He reaction, the proton beam was supplied by a 2 MeV Van de Graaff. The structure in {sup 56}Fe has been studied in a more detailed way by measuring six angular distributions in the above range and the elastic scattering excitation curves at four angles. The measurements have made it possible to show the existence of the compound nucleus, as well as the presence of an intermediate structure in certain nuclei. (author) [French] Nous avons mesure les sections efficaces totales neutroniques entre 400 keV et 1200 keV du fluor, de l'aluminium, du silicium, du phosphore, du vanadium, du chrome, du manganese, du fer, du nickel, du cobalt et du plomb avec une dispersion en energie de 3 keV. Les neutrons etaient produits a l'aide de la reaction T (p,n) {sup 3}He, les protons etant acceleres par un Van de Graaff 2 MeV. Nous presentons de plus quatre courbes d'excitation de la diffusion elastique des neutrons sur le fer ainsi que six distributions angulaires. Ces mesures ont permis de mettre en evidence un certain nombres de resonances du noyau compose, ainsi que la presence d'une structure intermediaire dans. certains noyaux. (auteur)

  4. Study of the X radiation between 10 and 100 keV produced in and above the atmosphere

    International Nuclear Information System (INIS)

    Rothenflug, Robert

    1969-01-01

    To measure the X radiation within this energy range we used a detector consisting of a NaI(Tl) scintillator combined with a photomultiplier, of surface area 7 cm 2 and yield close to 1 between 10 and 100 keV. The detection system was carried by stratospheric balloons to altitudes (of the order of 40 km) where the atmosphere was sufficiently transparent to allow observation of radiation from outside the atmosphere. At the same time the atmosphere is the centre of ionising radiations which give rise to parasitic X-rays in air and in the materials surrounding the detector. The first part of this report is devoted to a study of these parasitic radiations for the purpose of calculating the different components. The second part deals with diffuse X radiation of extra-terrestrial origin. Measurements of the radiation in 3 different directions showed that it is isotropic within the limits of experimental accuracy, of the order of 20 per cent. The diffuse X-ray spectrum takes the form dN/dE = (2.1 ± 0.4).10 2 E -2.43±0.05 ph/cm 2 .s.ster.keV for E expressed in keV, between 14 and 90 keV., The last part is devoted to a discussion on the possible origins of the diffuse radiation. (author) [fr

  5. 3.5 keV X-ray line signal from dark matter decay in local U(1){sub B−L} extension of Zee-Babu model

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Seungwon [School of Physics and Open KIAS Center, KIAS,85 Hoegiro Dongdaemun-gu, Seoul 130-722 (Korea, Republic of)

    2015-08-06

    We consider a local U(1){sub B−L} extension of Zee-Babu model to explain the recently observed 3.5 keV X-ray line signal. The model has three Standard model (SM)-singlet Dirac fermions with different U(1){sub B−L} charges. A complex scalar field charged under U(1){sub B−L} is introduced to break the U(1){sub B−L} symmetry. After U(1){sub B−L} symmetry breaking a remnant discrete symmetry stabilizes the lightest state of the Dirac fermions, which can be a stable dark matter (DM). The second lightest state, if mass splitting with the stable DM is about 3.5 keV, decays dominantly to the stable DM and 3.5 keV photon through two-loop diagrams, explaining the X-ray line signal. Two-loop suppression of the decay amplitude makes its lifetime much longer than the age of the universe and it can be a decaying DM candidate in large parameter region. We also introduce a real scalar field which is singlet under both the SM and U(1){sub B−L} and can explain the current relic abundance of the Dirac fermionic DMs. If the mixing with the SM Higgs boson is small, it does not contribute to DM direct detection. The main contribution to the scattering of DM off atomic nuclei comes from the exchange of U(1){sub B−L} gauge boson, Z{sup ′}, and is suppressed below current experimental bound when Z{sup ′} mass is heavy (≳10 TeV). If the singlet scalar mass is about 0.1–10 MeV, DM self-interaction can be large enough to solve small scale structure problems in simulations with the cold DM, such as, the core-vs-cusp problem and too-big-to-fail problem.

  6. Measurement of L-XRF cross-sections and Coster–Kronig enhancement factors for {sup 62}Sm at excitation energies 6.8, 7.4 and 8 KeV

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, R., E-mail: rajiv_005@rediffmail.com [Department of Physics, HCTM Technical Campus, Kaithal, Haryana 136027 (India); Rani, A., E-mail: anita_teotia@rediffmail.com [Department of Physics, University P.G. College Kurukshetra, Kurukshetra University, Kurukshetra, Haryana 136119 (India); Singh, R.M. [Department of Physics, Ch. Devi Lal University, Sirsa, Haryana 125055 (India); Tiwari, M.K.; Singh, A.K. [X-ray Optics Section, Indus Synchrotron Utilization Division, Raja Ramanna Centre for Advanced Technology, Indore, Madhya Pradesh 452013 (India)

    2016-05-15

    Highlights: • L XRF production cross-sections for {sup 62}Sm at excitation energies 6.8, 7.4 and 8 KeV were measured. • Synchrotron radiations with Peltier cooled Si(Li) detector was employed. • Experimental L XRF cross sections are in good agreement with the theoretical estimations of Puri’s data. • The present study was also carried out to examine the effect of Coster - Kronig transitions on L XRF cross section. • The measured enhancement factors are found to be smaller than the theoretical estimations. - Abstract: L{sub ℓ}, L{sub α} and L{sub β} XRF production cross-sections were measured for {sup 62}Sm at excitation energies i.e. 6.8 KeV, 7.4 KeV and 8 KeV using synchrotron radiations. Experimental measurements were also carried out to examine the effect of Coster–Kronig transitions (non-radiative transitions) on fluorescence cross section for the L{sub i} (i = 1, 2, 3) X-ray lines. The experimental cross-sections with greater accuracy and better signal to noise ratio can be measured using a polarized monoenergetic excitation beam and a high resolution detector system. A Peltier cooled vortex solid state detector with energy resolution of 138 eV at 5.959 keV X-ray was employed. Experimentally measured cross-sections have been compared with the theoretical predictions with the data of M.O. Krause [J. Phys. Chem. Ref. Data 8 (1979) 307], J.L. Campbell [At. Data Nucl. Data Tables 85 (2003) 291] and S. Puri et al. [X-Ray Spectrom. 22 (1993) 358]. The measured enhancement factors were found to be smaller than the theoretically calculated values.

  7. Cross sections for one-electron capture by highly stripped ions of Be, B and C from H2 and Ar below 10 keV

    International Nuclear Information System (INIS)

    Takagi, S.; Ohtani, S.; Kadota, K.; Fujita, J.

    1982-03-01

    Cross sections for one-electron capture by highly stripped ions of Be, B and C from H 2 and Ar are measured at low energies below 10 keV. The cross sections are nearly independent of the collision energy investigated. The distinct oscillation with incident ionic charge g in the cross sections are observed. (author)

  8. Intrinsic radioactivity of KSr2I5:Eu2+

    International Nuclear Information System (INIS)

    Rust, M.; Melcher, C.; Lukosi, E.

    2016-01-01

    A current need in nuclear security is an economical, yet high energy resolution (near 2%), scintillation detector suitable for gamma-ray spectroscopy. For current scintillators on the market, there is an inverse relationship between scintillator energy resolution and cost of production. A new promising scintillator, KSr 2 I 5 :Eu 2+ , under development at the University of Tennessee, has achieved an energy resolution of 2.4% at 662 keV at room temperature, with potential growth rates exceeding several millimeters per hour. However, the internal background due to the 40 K content could present a hurdle for effective source detection/identification in nuclear security applications. As a first step in addressing this question, this paper reports on a computational investigation of the intrinsic differential pulse height spectrum (DPHS) generated by 40 K within the KSr 2 I 5 :Eu 2+ scintillator as a function of crystal geometry. It was found that the DPHS remains relatively equal to a constant multiplicative factor of the negatron emission spectrum with a direct increase of the 1.46 MeV photopeak relative height to the negatron spectrum with volume. Further, peak pileup does not readily manifest itself for practical KSr 2 I 5 :Eu 2+ volumes.

  9. Weak Hard X-Ray Emission from Two Broad Absorption Line Quasars Observed with NuStar: Compton-Thick Absorption or Intrinsic X-Ray Weakness?

    Science.gov (United States)

    Luo, B.; Brandt, W. N.; Alexander, D. M.; Harrison, F. A.; Stern, D.; Bauer, F. E.; Boggs, S. E.; Christensen, F. E.; Comastri, A.; Craig, W. W..; hide

    2013-01-01

    We present Nuclear Spectroscopic Telescope Array (NuSTAR) hard X-ray observations of two X-ray weak broad absorption line (BAL) quasars, PG 1004+130 (radio loud) and PG 1700+518 (radio quiet). Many BAL quasars appear X-ray weak, probably due to absorption by the shielding gas between the nucleus and the accretion-disk wind. The two targets are among the optically brightest BAL quasars, yet they are known to be significantly X-ray weak at rest-frame 2-10 keV (16-120 times fainter than typical quasars). We would expect to obtain approx. or equal to 400-600 hard X-ray (is greater than or equal to 10 keV) photons with NuSTAR, provided that these photons are not significantly absorbed N(sub H) is less than or equal to 10(exp24) cm(exp-2). However, both BAL quasars are only detected in the softer NuSTAR bands (e.g., 4-20 keV) but not in its harder bands (e.g., 20-30 keV), suggesting that either the shielding gas is highly Compton-thick or the two targets are intrinsically X-ray weak. We constrain the column densities for both to be N(sub H) 7 × 10(exp 24) cm(exp-2) if the weak hard X-ray emission is caused by obscuration from the shielding gas. We discuss a few possibilities for how PG 1004+130 could have Compton-thick shielding gas without strong Fe Ka line emission; dilution from jet-linked X-ray emission is one likely explanation. We also discuss the intrinsic X-ray weakness scenario based on a coronal-quenching model relevant to the shielding gas and disk wind of BAL quasars. Motivated by our NuSTAR results, we perform a Chandra stacking analysis with the Large Bright Quasar Survey BAL quasar sample and place statistical constraints upon the fraction of intrinsically X-ray weak BAL quasars; this fraction is likely 17%-40%.

  10. WEAK HARD X-RAY EMISSION FROM TWO BROAD ABSORPTION LINE QUASARS OBSERVED WITH NuSTAR: COMPTON-THICK ABSORPTION OR INTRINSIC X-RAY WEAKNESS?

    Energy Technology Data Exchange (ETDEWEB)

    Luo, B.; Brandt, W. N. [Department of Astronomy and Astrophysics, 525 Davey Lab, The Pennsylvania State University, University Park, PA 16802 (United States); Alexander, D. M.; Hickox, R. [Department of Physics, Durham University, South Road, Durham DH1 3LE (United Kingdom); Harrison, F. A.; Fuerst, F.; Grefenstette, B. W.; Madsen, K. K. [Cahill Center for Astronomy and Astrophysics, California Institute of Technology, Pasadena, CA 91125 (United States); Stern, D. [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109 (United States); Bauer, F. E. [Departamento de Astronomia y Astrofisica, Pontificia Universidad Catolica de Chile, Casilla 306, Santiago 22 (Chile); Boggs, S. E.; Craig, W. W. [Space Sciences Laboratory, University of California, Berkeley, CA 94720 (United States); Christensen, F. E. [DTU Space-National Space Institute, Technical University of Denmark, Elektrovej 327, DK-2800 Lyngby (Denmark); Comastri, A. [INAF-Osservatorio Astronomico di Bologna, Via Ranzani 1, I-40127 Bologna (Italy); Fabian, A. C. [Institute of Astronomy, Madingley Road, Cambridge CB3 0HA (United Kingdom); Farrah, D. [Department of Physics, Virginia Tech, Blacksburg, VA 24061 (United States); Fiore, F. [Osservatorio Astronomico di Roma, via Frascati 33, I-00040 Monteporzio Catone (Italy); Hailey, C. J. [Columbia Astrophysics Laboratory, Columbia University, New York, NY 10027 (United States); Matt, G. [Dipartimento di Matematica e Fisica, Universita degli Studi Roma Tre, via della Vasca Navale 84, I-00146 Roma (Italy); Ogle, P. [IPAC, California Institute of Technology, Mail Code 220-6, Pasadena, CA 91125 (United States); and others

    2013-08-01

    We present Nuclear Spectroscopic Telescope Array (NuSTAR) hard X-ray observations of two X-ray weak broad absorption line (BAL) quasars, PG 1004+130 (radio loud) and PG 1700+518 (radio quiet). Many BAL quasars appear X-ray weak, probably due to absorption by the shielding gas between the nucleus and the accretion-disk wind. The two targets are among the optically brightest BAL quasars, yet they are known to be significantly X-ray weak at rest-frame 2-10 keV (16-120 times fainter than typical quasars). We would expect to obtain Almost-Equal-To 400-600 hard X-ray ({approx}> 10 keV) photons with NuSTAR, provided that these photons are not significantly absorbed (N{sub H} {approx}< 10{sup 24} cm{sup -2}). However, both BAL quasars are only detected in the softer NuSTAR bands (e.g., 4-20 keV) but not in its harder bands (e.g., 20-30 keV), suggesting that either the shielding gas is highly Compton-thick or the two targets are intrinsically X-ray weak. We constrain the column densities for both to be N{sub H} Almost-Equal-To 7 Multiplication-Sign 10{sup 24} cm{sup -2} if the weak hard X-ray emission is caused by obscuration from the shielding gas. We discuss a few possibilities for how PG 1004+130 could have Compton-thick shielding gas without strong Fe K{alpha} line emission; dilution from jet-linked X-ray emission is one likely explanation. We also discuss the intrinsic X-ray weakness scenario based on a coronal-quenching model relevant to the shielding gas and disk wind of BAL quasars. Motivated by our NuSTAR results, we perform a Chandra stacking analysis with the Large Bright Quasar Survey BAL quasar sample and place statistical constraints upon the fraction of intrinsically X-ray weak BAL quasars; this fraction is likely 17%-40%.

  11. Galaxy Clusters in the Swift/BAT era II: 10 more Clusters detected above 15 keV

    Energy Technology Data Exchange (ETDEWEB)

    Ajello, M.; /SLAC /KIPAC, Menlo Park; Rebusco, P.; /KIPAC, Menlo Park; Cappelluti, N.; /Garching, Max Planck Inst., MPE /Maryland U., Baltimore County; Reimer, O.; /SLAC /Palermo Observ.; Boehringer, H.; /Garching, Max Planck Inst., MPE; La Parola, V.; Cusumano, G.; /Palermo Observ.

    2010-10-27

    We report on the discovery of 10 additional galaxy clusters detected in the ongoing Swift/BAT all-sky survey. Among the newly BAT-discovered clusters there are: Bullet, Abell 85, Norma, and PKS 0745-19. Norma is the only cluster, among those presented here, which is resolved by BAT. For all the clusters we perform a detailed spectral analysis using XMM-Newton and Swift/BAT data to investigate the presence of a hard (non-thermal) X-ray excess. We find that in most cases the clusters emission in the 0.3-200 keV band can be explained by a multi-temperature thermal model confirming our previous results. For two clusters (Bullet and Abell 3667) we find evidence for the presence of a hard X-ray excess. In the case of the Bullet cluster, our analysis confirms the presence of a non-thermal, power-law like, component with a 20-100 keV flux of 3.4 x 10{sup -12} erg cm{sup -2} s{sup -1} as detected in previous studies. For Abell 3667 the excess emission can be successfully modeled as a hot component (kT = {approx}13 keV). We thus conclude that the hard X-ray emission from galaxy clusters (except the Bullet) has most likely thermal origin.

  12. GALAXY CLUSTERS IN THE SWIFT/BAT ERA. II. 10 MORE CLUSTERS DETECTED ABOVE 15 keV

    International Nuclear Information System (INIS)

    Ajello, M.; Reimer, O.; Rebusco, P.; Cappelluti, N.; Boehringer, H.; La Parola, V.; Cusumano, G.

    2010-01-01

    We report on the discovery of 10 additional galaxy clusters detected in the ongoing Swift/Burst Alert Telescope (BAT) all-sky survey. Among the newly BAT-discovered clusters there are Bullet, A85, Norma, and PKS 0745-19. Norma is the only cluster, among those presented here, which is resolved by BAT. For all the clusters, we perform a detailed spectral analysis using XMM-Newton and Swift/BAT data to investigate the presence of a hard (non-thermal) X-ray excess. We find that in most cases the clusters' emission in the 0.3-200 keV band can be explained by a multi-temperature thermal model confirming our previous results. For two clusters (Bullet and A3667), we find evidence for the presence of a hard X-ray excess. In the case of the Bullet cluster, our analysis confirms the presence of a non-thermal, power-law-like, component with a 20-100 keV flux of 3.4 x 10 -12 erg cm -2 s -1 as detected in previous studies. For A3667, the excess emission can be successfully modeled as a hot component (kT ∼ 13 keV). We thus conclude that the hard X-ray emission from galaxy clusters (except the Bullet) has most likely a thermal origin.

  13. Total bremsstrahlung spectra of thick lead compounds produced by {sup 90}Sr beta emitter in photon energy region of 10–100 keV

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Suhansar Jit [Department of Physics, B.B.S.B Polytechnic, Fatehgarh Sahib, Punjab (India); Singh, Tajinder, E-mail: tajindersingh2k9@gmail.com [Department of Physics, Mata Gujri College, Fatehgarh Sahib, Punjab (India); Singh, Doordarshi [Department of Mechanical Engineering, B.B.S.B Engineering College, Fatehgarh Sahib, Punjab (India); Singh, Amrit [Department of Physics, Baba Ajay Singh Khalsa College, Gurdas Nangal, Gurdaspur, Punjab (India); Dhaliwal, A.S. [Department of Physics, Sant Longowal Institute of Engineering & Technology, Longowal (Sangrur), Punjab (India)

    2017-06-15

    Highlights: • Total bremsstrahlung spectra in thick targets of Pb compounds by {sup 90}Sr in energy range 10–100 keV. • Experimental results show better agreement with the model which includes PB in SA up to 30 keV. • At higher photon energy region 30–100 keV the model which describes OB is more accurate. • Experimental results show positive deviations from the entire models at higher energy end spectrum. - Abstract: The total bremsstrahlung spectra in the thick targets of lead acetate trihydrate (Pb(CH{sub 3}COO){sub 2}·3H{sub 2}O), lead nitrate Pb(NO{sub 3}){sub 2} and lead chloride (PbCl{sub 2}) produced by {sup 90}Sr beta particles have been investigated in the photon energy region of 10–100 keV. The experimental bremsstrahlung spectra have been compared with the theoretical models Elwert corrected (non relativistic) Bethe Heitler theory, modified Elwert factor (relativistic) Bethe Heitler theory for ordinary bremsstrahlung and modified Elwert factor (relativistic) Bethe Heitler theory which includes polarization bremsstrahlung in the stripped atom approximation. The experimental results show better agreement with theoretical model that includes polarization bremsstrahlung in stripped approximation in the photon energy region below 30 keV. However, at higher photon energy region 30–100 keV, the theoretical model which describes ordinary bremsstrahlung is more accurate to describe the experimental bremsstrahlung spectra. The experimental results show positive deviations from the entire theoretical models at higher energy end of the spectrum. The results indicate that polarization bremsstrahlung plays important role in the formation of total bremsstrahlung spectra in lead compounds produced by continuous beta particles at low photon energy region of 10–30 keV.

  14. L-shell X-ray production of molybdenum and niobium induced by 1500–3500 keV Xe26+ ions

    International Nuclear Information System (INIS)

    Guo, Yipan; Yang, Zhihu; Song, Zhangyong; Xu, Qiumei; Chen, Jing; Yang, Bian

    2013-01-01

    L-shell X-ray production cross sections are measured for molybdenum and niobium target induced by Xe 26+ ions. The incident energy range varies from 1500 to 3500 keV. The experimental results are well reproduced by the binding-energy-modified binary encounter approximation model in the united-atom limit. In addition to target L-shell X-ray spectra, we also observe a weak spectrum which corresponds to the forbidden transition 3d → 2s from the projectiles

  15. Inelastic scattering of 275 keV neutrons by silver

    International Nuclear Information System (INIS)

    Litvinsky, L.L.; Zhigalov, Ya.A.; Krivenko, V.G.; Purtov, O.A.; Sabbagh, S.

    1997-01-01

    Neutron total, elastic and inelastic scattering cross-scattering of Ag at the E n = 275 KeV neutron energy were measured by using the filtered neutron beam of the WWR-M reactor in Kiev. The d-neutron strength function S n2 of Ag was determined from the analysis of all available data in the E n ≤ keV energy region on neutron inelastic scattering cross-sections with excitation of the first isomeric levels I π m = 7/2 + , E m ∼ 90 keV of 107,109 Ag: S n2 = (1.03 ± 0.19) · 10 -4 . (author). 10 refs, 3 figs

  16. Bragg concentrators for hard (> 10 keV) X-ray astronomy: Status report

    Energy Technology Data Exchange (ETDEWEB)

    Pareschi, G.; Pasqualini, G. [Ferrara, Univ. (Italy). Dipt. di Fisica; Frontera, F. [CNR, Bologna (Italy). Istituto di TESRE]|[Ferrara, Univ. (Italy). Dipt. di Fisica

    1997-09-01

    The use of focusing telescopes in hard X-ray (E > 10 keV) astronomy will provide better flux sensitivity and imaging performances with respect to the direct-viewing detectors, utilized until now. They present recent results obtained from their group regarding the possible use of Bragg-diffraction technique to design hard X-ray focusing telescopes.

  17. Bragg concentrators for hard (> 10 keV) X-ray astronomy: Status report

    International Nuclear Information System (INIS)

    Pareschi, G.; Pasqualini, G.; Frontera, F.; Ferrara, Univ.

    1997-01-01

    The use of focusing telescopes in hard X-ray (E > 10 keV) astronomy will provide better flux sensitivity and imaging performances with respect to the direct-viewing detectors, utilized until now. They present recent results obtained from their group regarding the possible use of Bragg-diffraction technique to design hard X-ray focusing telescopes

  18. Sputtering yields of YBa2Cu3O7 and Bi2Sr2Ca2Cu3O10 by 100 keV Ar+ impact at normal incidence

    International Nuclear Information System (INIS)

    Matsunami, N.

    1998-01-01

    The thickness change of YBa 2 Cu 3 O 7-δ (YBCO) and Bi 2 Sr 2 Ca 2 Cu 3 O 10-δ (Bi-2223) films by 100 keV Ar + impact at normal incidence has been measured using 1.8 MeV He Rutherford backscattering method. The sputtering yields of YBCO and Bi-2223 films are determined as 2.5 and 1.7 atoms per ion, respectively. A considerable segregation of Y is observed for YBCO by ion impact. Comparing the experimental sputtering yields with those of a computer simulation, the effective surface binding energies for the films of non-superconducting phase are obtained as 3.0 and 4.5 eV for YBCO and Bi-2223, respectively. These surface binding energies are compared with those of thermodynamics. (orig.)

  19. In situ thin film measurement by X-rays induced by 10 KeV-100 KeV ion beams

    International Nuclear Information System (INIS)

    Torrisi, L.; Calcagno, L.; Trovato, A.; Foti, G.

    1982-01-01

    The in situ measurement of thin film thickness between 50 and 100 KeV is described. The method used seems to be flexible enough and can be applied to any type of material. The only parameter intervening in the thickness measurement is the specific energy loss of the proton beams. Film of Al, Cu and Ag have been considered. When the primary beam energy increases the perception in depth of the method grows, reaching 10 μm with 1 MeV beam. In this case the autoabsorption takes place

  20. Electric dipole moments of He atoms excited to the 1s5l (l  ⩾ 2) states by He+-ion impact at intermediate energies

    International Nuclear Information System (INIS)

    Baszanowska, E; Drozdowski, R; Kamiński, P; Von Oppen, G

    2014-01-01

    The post-collisional 1s5l (l ⩾ 2) states of He atoms after He + -ion impact (10 keV–28 keV) have been investigated using anticrossing spectroscopy. In particular, the intensity of the spectral line λ(1s5l 3 D-1s2p 3 P) = 402.6 nm emitted by the impact-excited He atoms was measured as a function of an axial electric field (which varied from −30 kV cm −1 to +30 kV cm −1 ). By fitting the theoretical intensity functions to the measured ones, the post-collisional states of the atoms and their electric dipole moments were determined. The results indicate that for projectile energies below 20 keV, the electric dipole moments are small; however, for energies above 20 keV, mainly the parabolic Stark states with maximal electric dipole moments are excited. We conclude that in the upper section of the energy range investigated here, the Paul-trap promotion is the dominant excitation mechanism for He + –He collisions. (paper)

  1. SMM observations of gamma-ray transients. 2: A search for gamma-ray lines between 400 and 600 keV from the Crab Nebula

    Science.gov (United States)

    Harris, Michael J.; Share, Gerald H.; Leising, Mark D.

    1994-01-01

    We have search spectra obtained by the Solar Maximum Mission Gamma-Ray Spectrometer during 1981-1988 for evidence of transient gamma-ray lines from the Crab Nebula which have been reported by previous experiments at energies 400-460 keV and 539 keV. We find no evidence for significant emission in any of these lines on time scales between aproximately 1 day and approximately 1 yr. Our 3 sigma upper limits on the transient flux during 1 d intervals are approximately equal to 2.2 x 10(exp -3) photons/sq cm/s for narrow lines at any energy, and approximately equal to 2.9 x 10(exp -3) photons/sq cm/s for the 539 keV line if it is as broad as 42 keV Full Width at Half Maximum (FWHM). We also searched our data during the approximately 5 hr period on 1981 June 6 during which Owens, Myers, & Thompson (1985) reported a strong line at 405 keV. We detected no line down to a 3 upper sigma limit of 3.3 x 10(exp -3) photons/sq cm/s in disagreement with the flux 7.2 +/- 2.1 x 10(exp -3) photos/sq cm/s measured by Owens et al.

  2. Neutron resonance parameters of 96Zr below 100 keV

    International Nuclear Information System (INIS)

    Musgrove, A.R.D.

    1977-08-01

    Transmission data taken at the 80 m station of the Oak Ridge Electron Linear Accelerator have provided resonance parameters for 96 Zr to 100 keV. The average level spacing and neutron strength function for s-wave neutrons were as follows: = 8 +- 2 keV and S 0 = (0.21 +- 0.10) x 10 -4 . The average p-wave neutron strength function was S 1 = (7.4 +- 2.0) x 10 -4 . (Author)

  3. L X-ray fluorescence cross sections experimentally determined for elements with 45keV

    Energy Technology Data Exchange (ETDEWEB)

    Bonzi, Edgardo V., E-mail: bonzie@famaf.unc.edu.ar [Facultad de Matematica, Astronomia y Fisica, Universidad Nacional de Cordoba, Ciudad Universitaria-5010, Cordoba (Argentina); Badiger, Nagappa M. [Departments of Physics, Karnatak University, Dharwad 580 003, Karnataka (India); Grad, Gabriela B. [Facultad de Matematica, Astronomia y Fisica, Universidad Nacional de Cordoba, Ciudad Universitaria-5010, Cordoba (Argentina); Barrea, Raul A. [The Biophysics Collaborative Access Team (BioCAT), Dept of Biological Chemical, and Physical Sciences, Illinois Institute of Technology, Chicago, IL 60616 (United States); Figueroa, Rodolo G. [Departamento de Cs. Fisicas, Universidad de La Frontera, Temuco (Chile)

    2012-04-15

    Experimental determination of L fluorescence cross-sections for elements with 45keV using Synchrotron radiation. This work is part of an investigation we did at low energies in the same group of elements. The individual L X-ray photons, Ll, L{alpha}, L{beta}{sub I}, L{beta}{sub II}, L{gamma}{sub {Iota}} and L{gamma}{sub {Iota}{Iota}} produced in the target were measured using a Si(Li) detector. The experimental set-up provided a low background by using linearly polarized monoenergetic photon beam, improving the signal-to-noise ratio. The experimental cross sections obtained in this work were compared with data calculated using coefficients from , , and Scofield and Puri et al. (1993, 1995) - Highlights: Black-Right-Pointing-Pointer Experimental data of L fluorescence cross-sections with 45keV by Synchrotron radiation. Black-Right-Pointing-Pointer The cross sections Ll, L{alpha}, L{beta}{sub I}, L{beta}{sub II}, L{gamma}{sub {Iota}} and L{gamma}{sub {Iota}{Iota}} obtained, were compared with calculated data. Black-Right-Pointing-Pointer The Hypermet function was used to fit the data, because it considers a tail on the left side of the peak. Black-Right-Pointing-Pointer The tail is relevant when a small peak has another one on the right side with a big area.

  4. Acceleration of 100 keV protons using a 5SDH-2 Pelletron

    CERN Document Server

    Hollerman, W A; Ruzycki, N

    1999-01-01

    The authors successfully accelerated a 100 keV proton beam using a model 5SDH-2 Pelletron accelerator, manufactured by National Electrostatics Corporation (NEC). A pseudo-stable 1-2 nA beam was delivered on target with a net energy variation of less than 6%. However, the small terminal potential made it impossible to use standard stabilization techniques. Minor adjustments in terminal potential were required every 15 min to maintain beam current and energy. This level of stability is sufficient to deliver a proton fluence of 10 sup 1 sup 1 -10 sup 1 sup 2 cm sup - sup 2 to any desired target.

  5. X-ray detection with Micromegas with background levels below 10$^{-6}$ keV$^{-1}$cm$^{-2}$s$^{-1}$

    CERN Document Server

    Aune, S; Calvet, D.; Dafni, T.; Diago, A.; Druillole, F.; Fanourakis, G.; Ferrer-Ribas, E.; Galán, J.; García, J.A.; Gardikiotis, A.; Garza, J.G.; Geralis, T.; Giomataris, I.; Gómez, H.; González-Díaz, D.; Herrera, D.C.; Iguaz, F.J.; Irastorza, I.G.; Jourde, D.; Luzón, G.; Mirallas, H.; Mols, J.P.; Papaevangelou, T.; Rodríguez, A.; Seguí, L.; Tomás, A.; Vafeiadis, T.; Yildiz, S.C.

    2013-01-01

    Micromegas detectors are an optimum technological choice for the detection of low energy x-rays. The low background techniques applied to these detectors yielded remarkable background reductions over the years, being the CAST experiment beneficiary of these developments. In this document we report on the latest upgrades towards further background reductions and better understanding of the detectors' response. The upgrades encompass the readout electronics, a new detector design and the implementation of a more efficient cosmic muon veto system. Background levels below 10$^{-6}$keV$^{-1}$cm$^{-2}$s$^{-1}$ have been obtained at sea level for the first time, demonstrating the feasibility of the expectations posed by IAXO, the next generation axion helioscope. Some results obtained with a set of measurements conducted in the x-ray beam of the CAST Detector Laboratory will be also presented and discussed.

  6. Neutron transmission and capture measurements and analysis of 60Ni from 1 to 450 keV

    International Nuclear Information System (INIS)

    Perey, C.M.; Harvey, J.A.; Macklin, R.L.; Winters, R.R.; Perey, F.G.

    1982-11-01

    High-resolution transmission and capture measurements of 60 Ni-enriched targets have been made at the Oak Ridge Electron Linear Accelerator (ORELA) from a few eV to 1800 keV in transmission and from 2.5 keV to 5 MeV in capture . The transmission data from 1 to 450 keV were analyzed with a multi-level R-matrix code which uses the Bayes' theorem for the fitting process. This code provides the energies and neutron widths of the resonances inside the 1- to 450-keV region as well as a possible parameterization for outside resonances to describe the smooth cross section in this region. The capture data were analyzed with a least-squares fitting code using the Breit-Wigner formula. From 2.5 to 450 keV, 166 resonances were seen in both sets of data. Correspondence between the energy scales shows a discontinuity around 300 keV which makes the matching of resonances at higher energies difficult. Eighty-nine resonances were seen in the capture data only. Average parameters for the 30 observed s-wave resonances were deduced. The average level spacing D 0 was found to be equal to 15.2 +- 1.5 keV, the strength function, S 0 , equal to (2.2 +- 0.6) x 10 -4 and the average radiation width, GAMMA/sub γ/, equal to 1.30 +- 0.07 eV. The staircase plot of the reduced level widths and the plot of the Lorentz-weighted strength function averaged over various energy intervals show possible evidence for doorway states. The level densities calculated with the Fermi-gas model for l = 0 and for l > 0 resonances were compared with the cumulative number of observed resonances, but the analysis is not conclusive. The average capture cross section as a function of the neutron incident energy is compared to the tail of the giant electric dipole resonance prediction

  7. Comparison of measured and calculated 238U capture self-indication ratios from 4 to 10 keV

    International Nuclear Information System (INIS)

    Perez, R.B.; de Saussure, G.; Yang, J.T.; Munoz-Cobos, J.L.; Todd, J.H.

    1983-01-01

    From 4 keV to 149 keV the 238 U cross sections are represented in ENDF/B-V by unresolved-resonance parameters (URP). The purpose of this representation is to enable the calculation of resonance self-protection as a function of temperature and dilution. Since the URPs are not defined unambiguously by the cross-section data, it is important that the unresolved representation be tested with appropriate experiments, such as capture self-indication ratio (SIR) measurements. In this paper we compare 238 U capture SIR measurements in the 4- to 10-keV energy range with calculations done with ENDF/B-V and with recently published resolved resonance parameters

  8. FIRST INTEGRAL OBSERVATIONS OF V404 CYGNI DURING THE 2015 OUTBURST: SPECTRAL BEHAVIOR IN THE 20–650 KeV ENERGY RANGE

    Energy Technology Data Exchange (ETDEWEB)

    Roques, Jean-Pierre; Jourdain, Elisabeth [Université Toulouse, UPS-OMP, CNRS, IRAP, 9 Av. Roche, BP 44346, F-31028 Toulouse (France); Bazzano, Angela; Fiocchi, Mariateresa; Natalucci, Lorenzo; Ubertini, Pietro [Istituto di Astrofisica e Planetologia Spaziali, INAF, Via Fosso del Cavaliere 100, I-00133 Roma, Italy (Italy)

    2015-11-01

    In 2015 June, the source V404 Cygni (= GS2023+38) underwent an extraordinary outburst. We present the results obtained during the first revolution dedicated to this target by the INTEGRAL mission and focus on the spectral behavior in the hard X-ray domain, using both SPI and IBIS instruments. The source exhibits extreme variability and reaches fluxes of several tens of Crab. However, the emission between 20 and 650 keV can be understood in terms of two main components, varying on all the observable timescales, similar to what is observed in the persistent black hole system Cyg X-1. The low-energy component (up to ∼200 keV) presents a rather unusual shape, probably due to the intrinsic source variability. Nonetheless, a satisfactory description is obtained with a Comptonization model, if an unusually hot population of seed photons (kT{sub 0} ∼ 7 keV) is introduced. Above this first component, a clear excess extending up to 400–600 keV leads us to investigate a scenario where an additional (cutoff) power law could correspond to the contribution of the jet synchrotron emission, as proposed in Cyg X-1. A search for an annihilation feature did not provide any firm detection, with an upper limit of 2 × 10{sup −4} ph cm{sup −2} s{sup −1} (2σ) for a narrow line centered at 511 keV, on the averaged obtained spectrum.

  9. NuSTAR Reveals Extreme Absorption in z < 0.5 Type 2 Quasars

    Science.gov (United States)

    Lansbury, G. B.; Gandhi, P.; Alexander, D. M.; Assef, R. J.; Aird, J.; Annuar, A.; Ballantyne, D. R.; Baloković, M.; Bauer, F. E.; Boggs, S. E.; Brandt, W. N.; Brightman, M.; Christensen, F. E.; Civano, F.; Comastri, A.; Craig, W. W.; Del Moro, A.; Grefenstette, B. W.; Hailey, C. J.; Harrison, F. A.; Hickox, R. C.; Koss, M.; LaMassa, S. M.; Luo, B.; Puccetti, S.; Stern, D.; Treister, E.; Vignali, C.; Zappacosta, L.; Zhang, W. W.

    2015-08-01

    The intrinsic column density (NH) distribution of quasars is poorly known. At the high obscuration end of the quasar population and for redshifts z 1.5 × 1024 cm-2) type 2 quasars (CTQSO2s); five new NuSTAR observations are reported herein, and four have been previously published. The candidate CTQSO2s lie at z < 0.5, have observed [O iii] luminosities in the range 8.4\\lt {log}({L}[{{O} {{III}}]}/{L}⊙ )\\lt 9.6, and show evidence for extreme, Compton-thick absorption when indirect absorption diagnostics are considered. Among the nine candidate CTQSO2s, five are detected by NuSTAR in the high-energy (8-24 keV) band: two are weakly detected at the ≈3σ confidence level and three are strongly detected with sufficient counts for spectral modeling (≳90 net source counts at 8-24 keV). For these NuSTAR-detected sources direct (i.e., X-ray spectral) constraints on the intrinsic active galactic nucleus properties are feasible, and we measure column densities ≈2.5-1600 times higher and intrinsic (unabsorbed) X-ray luminosities ≈10-70 times higher than pre-NuSTAR constraints from Chandra and XMM-Newton. Assuming the NuSTAR-detected type 2 quasars are representative of other Compton-thick candidates, we make a correction to the NH distribution for optically selected type 2 quasars as measured by Chandra and XMM-Newton for 39 objects. With this approach, we predict a Compton-thick fraction of {f}{CT}={36}-12+14 %, although higher fractions (up to 76%) are possible if indirect absorption diagnostics are assumed to be reliable.

  10. Intrinsic radioactivity of KSr{sub 2}I{sub 5}:Eu{sup 2+}

    Energy Technology Data Exchange (ETDEWEB)

    Rust, M.; Melcher, C.; Lukosi, E., E-mail: elukosi@utk.edu

    2016-10-11

    A current need in nuclear security is an economical, yet high energy resolution (near 2%), scintillation detector suitable for gamma-ray spectroscopy. For current scintillators on the market, there is an inverse relationship between scintillator energy resolution and cost of production. A new promising scintillator, KSr{sub 2}I{sub 5}:Eu{sup 2+}, under development at the University of Tennessee, has achieved an energy resolution of 2.4% at 662 keV at room temperature, with potential growth rates exceeding several millimeters per hour. However, the internal background due to the {sup 40}K content could present a hurdle for effective source detection/identification in nuclear security applications. As a first step in addressing this question, this paper reports on a computational investigation of the intrinsic differential pulse height spectrum (DPHS) generated by {sup 40}K within the KSr{sub 2}I{sub 5}:Eu{sup 2+} scintillator as a function of crystal geometry. It was found that the DPHS remains relatively equal to a constant multiplicative factor of the negatron emission spectrum with a direct increase of the 1.46 MeV photopeak relative height to the negatron spectrum with volume. Further, peak pileup does not readily manifest itself for practical KSr{sub 2}I{sub 5}:Eu{sup 2+} volumes.

  11. Pressure effect in the X-ray intrinsic position resolution in noble gases and mixtures

    CERN Document Server

    Azevedo, C.D.R.

    2016-12-13

    A study of the gas pressure effect in the position resolution of an interacting X- or gamma-ray photon in a gas medium is performed. The intrinsic position resolution for pure noble gases (Argon and Xenon) and their mixtures with CO2 and CH4 were calculated for several gas pressures (1-10bar) and for photon energies between 5.4 and 60.0 keV, being possible to establish a linear match between the intrinsic position resolution and the inverse of the gas pressure in that energy range. In order to evaluate the quality of the method here described, a comparison between the available experimental data and the calculated one in this work, is done and discussed. In the majority of the cases, a strong agreement is observed.

  12. Electron capture by He2+ ions in collisions with H and H2 at impact energies below 10 keV

    International Nuclear Information System (INIS)

    Nutt, W.L.; McCullough, R.W.; Brady, K.; Shah, M.B.; Gilbody, H.B.

    1978-01-01

    Total cross sections for the process He 2+ + H(1s) → He + (Σn, 1) + H + involving capture into all final bound states of He + have been determined for 3 He 2+ ions in the range 1.5-9.0 keV using a furnace-target technique previously employed for similar measurements at higher impact energies. Measured cross sections are considerably smaller than those measured previously by Fite et al (Proc. R.Soc.; A268:527 (1962)) and are in better accord with recent theoretical estimates. A likely explanation for the discrepancy is given in terms of the corresponding cross sections for electron capture in He 2+ -H 2 collisions which have also been determined. (author)

  13. K-capture probabilities to 400. 56 and 279. 48 keV levels in the decay of /sup 75/Se

    Energy Technology Data Exchange (ETDEWEB)

    Singh, K; Sahota, H S

    1984-02-01

    Precisely calibrated high resolution intrinsic semiconductor detector has been used to find K-capture probabilities to 400.56 and 279.48 keV levels in the decay of /sup 75/Se. The measurement to 279.48 keV level is reported for the first time in literature.

  14. Total conversion coefficient of the 185 keV (10--7+) transition in sup(182m)Ta

    International Nuclear Information System (INIS)

    Suryanarayana, Ch.; Venkateswara Rao, N.; Raghavaiah, C.V.; Bhuloka Reddy, S.; Satyanarayana, G.; Sastry, D.L.

    1988-01-01

    The total conversion coefficient of the 185 keV (E3) isomeric transition in 182 Ta was measured for the first time using gamma intensity balance method. The experimental αsub(T) was obtained as 3.4 ± 0.2 consistent with the theoretical value (3.272) due to Rosel et al. The E3 transition probability was found to be hindered by a factor of 5.07x10 4 when compared to the single particle estimate. (author). 13 refs

  15. Distortion of He(2l2l') Fano lineshapes by strong post-collision interaction in H+-He collisions

    International Nuclear Information System (INIS)

    Moretto-Capelle, P.; Benhenni, M.; Bordenave-Montesquieu, D.; Bordenave-Montesquieu, A.

    1996-01-01

    The three-body post-collisional interaction (PCI) between the scattered proton, recoil target ion and emitted electron has been investigated by electron spectrometry near the 2l2l' helium resonances, in the 20-100 keV energy range (V p 0.9-2 au). Particular attention has been paid to the PCI deformations of the Fano lineshapes when V-vector'' p ≅ V-vector e (2l2l'). Their angle and collision velocity dependences have been studied for the first time experimentally. A large variety of lineshapes have been observed, all of them successfully described by a single formula. At the lowest proton velocities the rescattering effect (also called Coulomb two-path scattering) is seen. (Author)

  16. Cross section measurements of the 10B(d,n0)11C reaction below 160 keV

    International Nuclear Information System (INIS)

    Stave, S.; Ahmed, M. W.; Blackston, M. A.; Crowell, A. S.; Henshaw, S. S.; Howell, C. R.; Kingsberry, P.; Perdue, B. A.; Weller, H. R.; Antolak, A. J.; Doyle, B. L.; Rossi, P.; Prior, R. M.; Spraker, M. C.

    2008-01-01

    New data were taken at the Triangle Universities Nuclear Laboratory to investigate the plausibility of using low energy deuterons and the 10 B(d,n) 11 C reaction as a portable source of 6.3 MeV neutrons. Analysis of the data at and below incident deuteron energies of 160 keV indicates an n 0 neutron cross section that is lower than previous estimates by at least three orders of magnitude. In separate runs, deuterons with two different energies (160 and 140 keV) were stopped in a 10 B target. The resulting n 0 neutrons of approximately 6.3 MeV were detected at angles between 0 deg. and 150 deg. The angle integrated yields were used to determine the astrophysical S factor for this reaction assuming a constant value for the S factor below 160 keV. The cross sections reported between 130 and 160 keV were calculated using the extracted value of the S factor. The measured n 0 cross section is several orders of magnitude smaller than previous results, thus eliminating 10 B(d,n) 11 C as a portable source of intense neutrons with low energy deuteron beams on the order of tens of microamps. In order to gain insight into the reaction dynamics at these low energies the cross section results have been compared with results from calculations using the distorted wave Born approximation (DWBA) and a detailed Hauser-Feshbach calculation performed by the authors. The angular distribution is consistent with the Hauser-Feshbach calculation suggesting a statistical compound nucleus reaction rather than a direct reaction

  17. Diamagnetism of the B10H12L2 series compounds

    International Nuclear Information System (INIS)

    Volkov, V.V.; Ikorskij, V.N.; Dunaev, S.T.

    1988-01-01

    The method of static magnetic susceptibility is used to study diamagnetic susceptibilities of a number of B 10 H 12 L 2 (where L - nitrogen, sulfur, phosphorus-containing organic ligands) decaborane-derivatives and to draw the increment χ M -125 for the nido cluster (B 10 H 12 ) and boron atomic increment χ bar M -9.0 in this cluster. The absolute value χ B in (B 10 H 12 ) cluster is much higher than χ B for noncluster systems (2.7-7.6). This difference proves electron delocalization in (B 10 H 12 ) and the aromatic nature of this nido-cluster

  18. The 10B(p,α)7Be S(E)-factor from 5 keV to 1.5 MeV using the Trojan Horse Method

    Science.gov (United States)

    Puglia, Sebastiana Maria Regina; Spitaleri, Claudio; La Cognata, Marco; Lamia, Livio; Broggini, Carlo; Caciolli, Antonio; Carlin, Nelson; Cherubini, Silvio; Cvetinovic, Alexandra; D'Agata, Giuseppe; Dell'aquila, Daniele; Depalo, Rosanna; Gulino, Marisa; Guardo, Giovanni Luca; Indelicato, Iolanda; Lombardo, Ivano; Menegazzo, Roberto; Munhoz, Marcelo Gimenez; Pizzone, Rosario Gianluca; Rapisarda, Giuseppe Gabriele; Rigato, Valentino; Romano, Stefano; Sergi, Maria Letizia; Souza, Francisco; Sparta, Roberta; Tudisco, Salvo; Tumino, Aurora

    2018-01-01

    The 10B(p,α)7Be reaction is the main responsible for the 10B destruction in stellar interior [1]. In such environments this p-capture process occurs at a Gamow energy of 10 keV and takes places mainly through a resonant state (Ex = 8.701 MeV) of the compound 11C nucleus. Thus a resonance right in the region of the Gamow peak is expected to significantly influence the behavior of the astrophysical S(E)-factor. The 10B(p,α)7Be reaction was studied via the Trojan Horse Method (THM) applied to the 2H(10B,α7Be)n in order to extract the astrophysical S(E)-factor in a wide energy range from 5 keV to 1.5 MeV.

  19. Elastic and inelastic processes in He+-H2 collisions between 2 and 30 keV

    International Nuclear Information System (INIS)

    Bergnes, C.; Bordenave-Montesquieu, D.; Boutonnet, A.; Nouet, P.; Dagnac, R.

    1986-01-01

    The elastic and inelastic processes have been studied for scattering of He + ions by H 2 molecules between 2 and 30 keV in the angular range from 10' to 3 0 by an energy loss technique. The analysis of elastic energy loss against E 0 theta 2 shows that the incident ion is scattered by the entire molecule at low energies whereas at high energies it is scattered by only one atom in the target. Comparison of the relative probabilities of the various excitation processes with the isoelectronic system He + -He demonstrates the different behaviours of a molecular target in the excitation mechanism. (author)

  20. Contribution to the study of (d,p) and (d,{alpha}> reactions on {sup 16}O and {sup 11}B from 200 keV to 1 MeV; Contribution a l'etude des reactions (d,p) et (d,{alpha}) sur {sup 16}O et {sup 11}B de 200 keV a 1 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Longequeue, N [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1965-05-01

    The reactions {sup 16}O(d,{alpha}{sub 0}), (d,p{sub 0}), (d,p{sub 1}) and {sup 11}B(d,{alpha}{sub 0}), (d,{alpha}{sub 2}), (d,p{sub 0}) have been studied from 200 keV to 1 MeV. The interpretation of (d,{alpha}) reactions by the compound nucleus theory has shown the presence of {sup 18}F levels (7,94 MeV, 1+; 8,09 MeV, 1+ ) and of {sup 13}C level (19 MeV, 3/2{+-} or 5/2-). The interpretation of {sup 16}O(d,p{sub 1}) and {sup 11}B(d,p{sub 0}) reactions at energies lower than 400 keV has been given by a theory of Coulomb stripping. (author) [French] L'etude experimentale des reactions {sup 16}O(d,{alpha}{sub 0}); (d,p{sub 0}), (d,p{sub 1}) et {sup 11}B(d,{alpha}{sub 0}), (d,{alpha}{sub 2}), (d,p{sub 0}) a ete faite de 200 keV a 1 Mev. L'interpretation des reactions (d,a) par la theorie du noyau compose a permis la mise en evidence de niveaux du {sup 18}F (7,94 MeV, 1+; 8,09MeV, 1+ ) et du {sup 13}C(19 MeV, 3/2{+-} ou 5/2-). L'interpretation des reactions {sup 16}O(d,p{sub 1}) et {sup 11}B(d,p{sub 0}), a basse energie (< 400 keV), par une theorie de stripping de Coulomb, a ete donnee.

  1. NuSTAR and XMM-Newton observations of luminous, heavily obscured, WISE-selected quasars at z ∼ 2

    Energy Technology Data Exchange (ETDEWEB)

    Stern, D.; Eisenhardt, P. R. M. [Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Mail Stop 169-221, Pasadena, CA 91109 (United States); Lansbury, G. B.; Alexander, D. M.; Del Moro, A.; Gandhi, P. [Department of Physics, University of Durham, South Road, Durham DH1 3LE (United Kingdom); Assef, R. J. [Núcleo de Astronomía de la Facultad de Ingeniería, Universidad Diego Portales, Av. Ejército Libertador 441, Santiago (Chile); Brandt, W. N.; Griffith, R. L. [Department of Astronomy and Astrophysics, The Pennsylvania State University, 525 Davey Lab, University Park, PA 16802 (United States); Ballantyne, D. R. [Center for Relativistic Astrophysics, School of Physics, Georgia Institute of Technology, Atlanta, GA 30332 (United States); Baloković, M.; Bridge, C. [Cahill Center for Astronomy and Astrophysics, California Institute of Technology, Pasadena, CA 91125 (United States); Bauer, F. E. [Instituto de Astrofísica, Facultad de Física, Pontificia Universidad Católica de Chile, 306, Santiago 22 (Chile); Benford, D. [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Blain, A. [Physics and Astronomy, University of Leicester, 1 University Road, Leicester, LE1 7RH (United Kingdom); Boggs, S. E.; Craig, W. W. [Space Sciences Laboratory, University of California, Berkeley, 7 Gauss Way, Berkeley, CA 94720-7450 (United States); Brightman, M. [Max-Planck-Institut für extraterrestrische Physik, Giessenbachstrasse 1, D-85748, Garching bei München (Germany); Christensen, F. E. [Danish Technical University, DK-2800 Lyngby (Denmark); Comastri, A., E-mail: daniel.k.stern@jpl.nasa.gov [INAF Osservatorio Astronomico di Bologna, via Ranzani 1, I-40127, Bologna (Italy); and others

    2014-10-20

    We report on a NuSTAR and XMM-Newton program that has observed a sample of three extremely luminous, heavily obscured WISE-selected active galactic nuclei (AGNs) at z ∼ 2 across a broad X-ray band (0.1 – 79 keV). The parent sample, selected to be faint or undetected in the WISE 3.4 μm (W1) and 4.6 μm (W2) bands but bright at 12 μm (W3) and 22 μm (W4), are extremely rare, with only ∼1000 so-called 'W1W2-dropouts' across the extragalactic sky. Optical spectroscopy reveals typical redshifts of z ∼ 2 for this population, implying rest-frame mid-IR luminosities of νL {sub ν}(6 μm) ∼ 6 × 10{sup 46} erg s{sup –1} and bolometric luminosities that can exceed L {sub bol} ∼ 10{sup 14} L {sub ☉}. The corresponding intrinsic, unobscured hard X-ray luminosities are L(2-10 keV) ∼ 4 × 10{sup 45} erg s{sup –1} for typical quasar templates. These are among the most AGNs known, though the optical spectra rarely show evidence of a broad-line region and the selection criteria imply heavy obscuration even at rest-frame 1.5 μm. We designed our X-ray observations to obtain robust detections for gas column densities N {sub H} ≤ 10{sup 24} cm{sup –2}. In fact, the sources prove to be fainter than these predictions. Two of the sources were observed by both NuSTAR and XMM-Newton, with neither being detected by NuSTAR (f {sub 3-24} {sub keV} ≲ 10{sup –13} erg cm{sup –2} s{sup –1}), and one being faintly detected by XMM-Newton (f {sub 0.5-10} {sub keV} ∼ 5 × 10{sup –15} erg cm{sup –2} s{sup –1}). A third source was observed only with XMM-Newton, yielding a faint detection (f {sub 0.5-10} {sub keV} ∼ 7 × 10{sup –15} erg cm{sup –2} s{sup –1}). The X-ray data imply these sources are either X-ray weak, or are heavily obscured by column densities N {sub H} ≳ 10{sup 24} cm{sup –2}. The combined X-ray and mid-IR analysis seems to favor this second possibility, implying the sources are extremely obscured, consistent with Compton

  2. NuSTAR and XMM-Newton observations of luminous, heavily obscured, WISE-selected quasars at z ∼ 2

    International Nuclear Information System (INIS)

    Stern, D.; Eisenhardt, P. R. M.; Lansbury, G. B.; Alexander, D. M.; Del Moro, A.; Gandhi, P.; Assef, R. J.; Brandt, W. N.; Griffith, R. L.; Ballantyne, D. R.; Baloković, M.; Bridge, C.; Bauer, F. E.; Benford, D.; Blain, A.; Boggs, S. E.; Craig, W. W.; Brightman, M.; Christensen, F. E.; Comastri, A.

    2014-01-01

    We report on a NuSTAR and XMM-Newton program that has observed a sample of three extremely luminous, heavily obscured WISE-selected active galactic nuclei (AGNs) at z ∼ 2 across a broad X-ray band (0.1 – 79 keV). The parent sample, selected to be faint or undetected in the WISE 3.4 μm (W1) and 4.6 μm (W2) bands but bright at 12 μm (W3) and 22 μm (W4), are extremely rare, with only ∼1000 so-called 'W1W2-dropouts' across the extragalactic sky. Optical spectroscopy reveals typical redshifts of z ∼ 2 for this population, implying rest-frame mid-IR luminosities of νL ν (6 μm) ∼ 6 × 10 46 erg s –1 and bolometric luminosities that can exceed L bol ∼ 10 14 L ☉ . The corresponding intrinsic, unobscured hard X-ray luminosities are L(2-10 keV) ∼ 4 × 10 45 erg s –1 for typical quasar templates. These are among the most AGNs known, though the optical spectra rarely show evidence of a broad-line region and the selection criteria imply heavy obscuration even at rest-frame 1.5 μm. We designed our X-ray observations to obtain robust detections for gas column densities N H ≤ 10 24 cm –2 . In fact, the sources prove to be fainter than these predictions. Two of the sources were observed by both NuSTAR and XMM-Newton, with neither being detected by NuSTAR (f 3-24 keV10 –13 erg cm –2 s –1 ), and one being faintly detected by XMM-Newton (f 0.5-10 keV ∼ 5 × 10 –15 erg cm –2 s –1 ). A third source was observed only with XMM-Newton, yielding a faint detection (f 0.5-10 keV ∼ 7 × 10 –15 erg cm –2 s –1 ). The X-ray data imply these sources are either X-ray weak, or are heavily obscured by column densities N H ≳ 10 24 cm –2 . The combined X-ray and mid-IR analysis seems to favor this second possibility, implying the sources are extremely obscured, consistent with Compton-thick, luminous quasars. The discovery of a significant population of heavily obscured, extremely luminous AGNs would not conform to the standard

  3. 500 keV, 10 kW DC electron accelerator at BRIT, Vashi

    International Nuclear Information System (INIS)

    Sharma, D.K.; Rajan, R.N.; Bakhtsingh, R.I.; Acharya, S.; Rajawat, R.K.

    2017-01-01

    The 500 keV DC accelerator was indigenously designed and developed by Accelerator and Pulse Power Division, BARC during 1994-97 and commissioned at REPF Hall, BRIT, Vashi on 10"t"h August, 1998. The accelerator operation at 3kW beam power for 8 hour shifts was established in February 2001, confirming to industrial standards for EB treatment of plastic sheets as well as various surface-treatment processes for value addition of the products and materials. Since then, this EB facility is functional and being regularly utilized for various applications

  4. IC 3639—a New Bona Fide Compton-Thick AGN Unveiled by NuSTAR

    Science.gov (United States)

    Boorman, Peter G.; Gandhi, P.; Alexander, D. M.; Annuar, A.; Ballantyne, D. R.; Bauer, F.; Boggs, S. E.; Brandt, W. N.; Brightman, M.; Christensen, F. E.; Craig, W. W.; Farrah, D.; Hailey, C. J.; Harrison, F. A.; Hönig, S. F.; Koss, M.; LaMassa, S. M.; Masini, A.; Ricci, C.; Risaliti, G.; Stern, D.; Zhang, W. W.

    2016-12-01

    We analyze high-quality NuSTAR observations of the local (z = 0.011) Seyfert 2 active galactic nucleus (AGN) IC 3639, in conjunction with archival Suzaku and Chandra data. This provides the first broadband X-ray spectral analysis of the source, spanning nearly two decades in energy (0.5-30 keV). Previous X-ray observations of the source below 10 keV indicated strong reflection/obscuration on the basis of a pronounced iron fluorescence line at 6.4 keV. The hard X-ray energy coverage of NuSTAR, together with self-consistent toroidal reprocessing models, enables direct broadband constraints on the obscuring column density of the source. We find the source to be heavily Compton-thick (CTK) with an obscuring column in excess of 3.6× {10}24 cm-2, unconstrained at the upper end. We further find an intrinsic 2-10 keV luminosity of {{log}}10({L}2{--10{keV}} [{erg} {{{s}}}-1])={43.4}-1.1+0.6 to 90% confidence, almost 400 times the observed flux, and consistent with various multiwavelength diagnostics. Such a high ratio of intrinsic to observed flux, in addition to an Fe-Kα fluorescence line equivalent width exceeding 2 keV, is extreme among known bona fide CTK AGNs, which we suggest are both due to the high level of obscuration present around IC 3639. Our study demonstrates that broadband spectroscopic modeling with NuSTAR enables large corrections for obscuration to be carried out robustly and emphasizes the need for improved modeling of AGN tori showing intense iron fluorescence.

  5. Measurement of the 232Th neutron capture cross section in the region 5 keV-150 keV

    International Nuclear Information System (INIS)

    Lobo, Georges; Corvi, Franco; Schillebeeckx, Peter; Brusegan, Antonio; Mutti, Paolo; Janeva, Natalia

    2002-01-01

    The average capture cross-section of 232 Th has been measured at the 14.37 m flight path of GELINA, IRMM-Geel, in the energy range from 5 to 150 keV. The capture events were detected by two C 6 D 6 liquid scintillators and the neutron flux was measured with a 10 B-loaded ionisation chamber. The data, corrected with the pulse-height weighting technique, have been normalised to the well-isolated and nearly saturated 232 Th (n, γ) resonances at 21.8 eV and 23.5 eV. Below 15 keV neutron energy, we do not observe the discrepancies, up to 40%, with the evaluated ENDF/B-VI data as reported by Wisshak et al.. Between 5 and 80 keV our results are about 10% systematically above the ENDF/B-VI data and approach the evaluated data between 80 and 100 keV. (author)

  6. Distortion of He(2l2l`) Fano lineshapes by strong post-collision interaction in H{sup +}-He collisions

    Energy Technology Data Exchange (ETDEWEB)

    Moretto-Capelle, P.; Benhenni, M.; Bordenave-Montesquieu, D.; Bordenave-Montesquieu, A. [Toulouse-3 Univ., 31 (France)

    1996-05-28

    The three-body post-collisional interaction (PCI) between the scattered proton, recoil target ion and emitted electron has been investigated by electron spectrometry near the 2l2l` helium resonances, in the 20-100 keV energy range (V{sub p} 0.9-2 au). Particular attention has been paid to the PCI deformations of the Fano lineshapes when V-vector``{sub p} {approx_equal} V-vector {sub e}(2l2l`). Their angle and collision velocity dependences have been studied for the first time experimentally. A large variety of lineshapes have been observed, all of them successfully described by a single formula. At the lowest proton velocities the rescattering effect (also called Coulomb two-path scattering) is seen. (Author).

  7. Study of the double charge-changing collision cross-sections of H{sup +}, D{sup +}, Li{sup +} ions with organic molecules in the energy range 10-50 keV; Etude des sections efficaces de double echange de charges ({sigma}{sub 1-1}) d'ions H{sup +}, D{sup +}, Li{sup +} traversant differents gaz organiques dans une gamme d'energie comprise entre 10 et 50 keV

    Energy Technology Data Exchange (ETDEWEB)

    Farrokhi, S [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1966-07-01

    The variation of the double charge-changing collision cross-sections of H{sup +}, D{sup +}, Li{sup +} ions with organic molecules (CH{sub 4}, C{sub 2}H{sub 6}, C{sub 3}H{sub 8}, C{sub 4}H{sub 10}) in the energy range 10-50 keV has been studied. Several maximums for {sigma}{sub 1-1} = f(E) have been shown. Their existence should be explained by the different possibilities of dissociating the target-molecules. The position of the maximums, for the H{sup +} {yields} H{sup -} and D{sup +} {yields} D{sup -} reactions is in good agreement with that defined by the Massey adiabatic relation. (author) [French] Nous avons etudie la variation de la section efficace de double echange de charges des ions H{sup +}, D{sup +}, Li{sup +} lors de la collision avec les molecules organiques de CH{sub 4}, C{sub 2}H{sub 6}, C{sub 3}H{sub 8}, C{sub 4}H{sub 10} dans la gamme d'energie comprise entre 10 et 50 keV. Les resultats obtenus ont montre plusieurs maximums de {sigma}{sub 1-1} f(E). L'existence de ces maximums pourrait etre expliquee par les differentes possibilites de dissociation des molecules cibles. La position des points maximaux concernant les reactions H{sup +} {yields} H{sup -} et D{sup +} {yields} D{sup -} est en bon accord avec celle definie par la relation adiabatique de MASSEY. (auteur)

  8. Characterization of the intrinsic scintillator Cs2LiCeCl6

    Energy Technology Data Exchange (ETDEWEB)

    James, R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-10-02

    In this work, we report on the scintillation properties of the intrinsic scintillator Cs2LiCeCl6 (CLCC), which is potentially useful for dual gamma-ray and neutron detection. CLCC is from the elpasolite family with a cubic structure. We grew the crystals at BNL by the vertical Bridgman growth technique. The luminescence spectrum of CLCC showed a doublet with peak maxima at 384 nm and 402 nm. The light yield of CLCC was approximately 20,000 photons/MeV, and the energy resolution was about 6% for 662-keV gamma radiation. A scintillation decay of ~81% of the total light was observed to be ~ 90 nanoseconds.

  9. Generation of L sub-shell photo-ionization cross-sections for elements 18Z92 at energies .320-115.606 keV (A computer program 'LSPICS')

    International Nuclear Information System (INIS)

    Sharma, Ajay; Mittal, Raj

    2005-01-01

    L sub-shell photo-ionization cross-sections, σ Li , for elements 18Z92 at energies .320-115.606 keV have been generated from an empirical relation fitted to Scofield's L sub-shell photo-ionization cross-section values. The excitation energy E for an element is constrained by the condition that only L and higher shell vacancies are produced in the elements. The closeness of generated and existing values of Scofield's L sub-shell data recommends the use of generated values in the fields of atomic and molecular physics and for trace elemental analysis. For this purpose computer software 'LSPICS' has been developed. On personal computer LSPICS generates L sub-shell photo-ionization cross-section values in barns just by entering the atomic number of element and excitation photon energy in keV

  10. Characterization of the PILATUS photon-counting pixel detector for X-ray energies from 1.75 keV to 60 keV

    International Nuclear Information System (INIS)

    Donath, T; Brandstetter, S; Commichau, S; Hofer, P; Lüthi, B; Schneebeli, M; Schulze-Briese, C; Cibik, L; Krumrey, M; Marggraf, S; Müller, P; Wernecke, J

    2013-01-01

    The PILATUS detector module was characterized in the PTB laboratory at BESSY II comparing modules with 320 μm thick and newly developed 450 μm and 1000 μm thick silicon sensors. Measurements were carried out over a wide energy range, in-vacuum from 1.75 keV to 8.8 keV and in air from 8 keV to 60 keV. The quantum efficiency (QE) was measured as a function of energy and the spatial resolution was measured at several photon energies both in terms of the modulation transfer function (MTF) from edge profile measurements and by directly measuring the point spread function (PSF) of a single pixel in a raster scan with a pinhole beam. Independent of the sensor thickness, the measured MTF and PSF come close to those for an ideal pixel detector with the pixel size of the PILATUS detector (172 × 172 μm 2 ). The measured QE follows the values predicted by calculation. Thicker sensors significantly enhance the QE of the PILATUS detectors for energies above 10 keV without impairing the spatial resolution and noise-free detection. In-vacuum operation of the PILATUS detector is possible at energies as low as 1.75 keV.

  11. Characterization of the PILATUS photon-counting pixel detector for X-ray energies from 1.75 keV to 60 keV

    Science.gov (United States)

    Donath, T.; Brandstetter, S.; Cibik, L.; Commichau, S.; Hofer, P.; Krumrey, M.; Lüthi, B.; Marggraf, S.; Müller, P.; Schneebeli, M.; Schulze-Briese, C.; Wernecke, J.

    2013-03-01

    The PILATUS detector module was characterized in the PTB laboratory at BESSY II comparing modules with 320 μm thick and newly developed 450 μm and 1000 μm thick silicon sensors. Measurements were carried out over a wide energy range, in-vacuum from 1.75 keV to 8.8 keV and in air from 8 keV to 60 keV. The quantum efficiency (QE) was measured as a function of energy and the spatial resolution was measured at several photon energies both in terms of the modulation transfer function (MTF) from edge profile measurements and by directly measuring the point spread function (PSF) of a single pixel in a raster scan with a pinhole beam. Independent of the sensor thickness, the measured MTF and PSF come close to those for an ideal pixel detector with the pixel size of the PILATUS detector (172 × 172 μm2). The measured QE follows the values predicted by calculation. Thicker sensors significantly enhance the QE of the PILATUS detectors for energies above 10 keV without impairing the spatial resolution and noise-free detection. In-vacuum operation of the PILATUS detector is possible at energies as low as 1.75 keV.

  12. X-radiation /E greater than 10 keV/, H-alpha and microwave emission during the impulsive phase of solar flares.

    Science.gov (United States)

    Vorpahl, J. A.

    1972-01-01

    A study has been made of the variation in hard (E greater than 10 keV) X-radiation, H-alpha and microwave emission during the impulsive phase of solar flares. Analysis shows that the rise-time in the 20-30-keV X-ray spike depends on the electron hardness. The impulsive phase is also marked by an abrupt, very intense increase in H-alpha emission in one or more knots of the flare. Properties of these H-alpha kernels include: (1) a luminosity several times greater than the surrounding flare, (2) an intensity rise starting about 20-30 sec before, peaking about 20-25 sec after, and lasting about twice as long as the hard spike, (3) a location lower in the chromosphere than the remaining flare, (4) essentially no expansion prior to the hard spike, and (5) a position within 6000 km of the boundary separating polarities, usually forming on both sides of the neutral line near both feet of the same tube of force. Correspondingly, impulsive microwave events are characterized by: (1) great similarity in burst structure with 20-32 keV X-rays but only above 5000 MHz, (2) typical low frequency burst cutoff between 1400-3800 MHz, and (3) maximum emission above 7500 MHz.

  13. Depth distribution of 2-keV helium-ion irradiation-induced cavities in nickel

    International Nuclear Information System (INIS)

    Fenske, G.; Das, S.K.; Kaminsky, M.

    1981-01-01

    Transmission electron microscopy has been used to study the effect of total dose on the depth distribution of cavities (voids or bubbles) in nickel irradiated at 500 0 C with 20-keV 4 He + ions. A transverse sectioning technique allowed us to obtain the entire depth distribution of cavities from a single specimen. The diameter, number density and volume fraction of cavities were measured as a function of depth from micrographs taken from samples sectioned parallel to the direction of the incident beam. Results for the doses at 2.9 x 10 15 and 2.9 x 10 16 ions/cm 2 show an increase in the average cavity diameter, number density and volume fraction with increasing dose. A further increase in dose from 2.9 x 10 16 to 2.9 x 10 17 ions/cm 2 also shows an increase in the average cavity diameter but a decrease in the number density. This observation is interpreted as evidence for the coalescence of cavities. 3 figures, 1 table

  14. The Frequency of Intrinsic X-Ray Weakness among Broad Absorption Line Quasars

    Science.gov (United States)

    Liu, Hezhen; Luo, B.; Brandt, W. N.; Gallagher, S. C.; Garmire, G. P.

    2018-06-01

    We present combined ≈14–37 ks Chandra observations of seven z = 1.6–2.7 broad absorption line (BAL) quasars selected from the Large Bright Quasar Survey (LBQS). These seven objects are high-ionization BAL (HiBAL) quasars, and they were undetected in the Chandra hard band (2–8 keV) in previous observations. The stacking analyses of previous Chandra observations suggested that these seven objects likely contain some candidates for intrinsically X-ray weak BAL quasars. With the new Chandra observations, six targets are detected. We calculate their effective power-law photon indices and hard-band flux weakness, and find that two objects, LBQS 1203+1530 and LBQS 1442–0011, show soft/steep spectral shapes ({{{Γ }}}eff}={2.2}-0.9+0.9 and {1.9}-0.8+0.9) and significant X-ray weakness in the hard band (by factors of ≈15 and 12). We conclude that the two HiBAL quasars are good candidates for intrinsically X-ray weak BAL quasars. The mid-infrared-to-ultraviolet spectral energy distributions of the two candidates are consistent with those of typical quasars. We constrain the fraction of intrinsically X-ray weak active galactic nuclei (AGNs) among HiBAL quasars to be ≈7%–10% (2/29–3/29), and we estimate it is ≈6%–23% (2/35–8/35) among the general BAL quasar population. Such a fraction is considerably larger than that among non-BAL quasars, and we suggest that intrinsically X-ray weak quasars are preferentially observed as BAL quasars. Intrinsically X-ray weak AGNs likely comprise a small minority of the luminous type 1 AGN population, and they should not affect significantly the completeness of these AGNs found in deep X-ray surveys.

  15. L{sub {iota}}, L{sub {alpha}}, L{sub {beta}} and L{sub {gamma}} X-ray fluorescence cross-sections of heavy elements for the exciting photons energy 38.18, 43.95, 50.21 and 59.5 keV

    Energy Technology Data Exchange (ETDEWEB)

    Bastug, Arif [Department of Physics Education, College of Education, Erzincan University, 24030 Erzincan (Turkey)], E-mail: abastug40@hotmail.com

    2008-03-15

    The cross-sections for the production of L{sub {iota}}, L{sub {alpha}}, L{sub {beta}} and L{sub {gamma}} X-ray fluorescence (XRF) in Er, Ta, W, Au, Hg, Tl, Pb and Bi by photons with energies in the range 38-59.5 keV have been measured, using a standard doublereflection experimental set-up. Measurements have been performed using an annular 241 Am primary source and X-ray emitting secondary-exciter system. Experimental cross-sections have been compared with the theoretically calculated values of L X-ray cross-sections and fairly good agreement is observed between the experimental and theoretical values.

  16. MODIS/Aqua Aerosol 5-Min L2 Swath 10km V006

    Data.gov (United States)

    National Aeronautics and Space Administration — The MODIS/Aqua Aerosol 5-Min L2 Swath 10km (MYD04_L2) product continues to provide full global coverage of aerosol properties from the Dark Target (DT) and Deep Blue...

  17. Loss of MutL Disrupts CHK2-Dependent Cell-Cycle Control through CDK4/6 to Promote Intrinsic Endocrine Therapy Resistance in Primary Breast Cancer.

    Science.gov (United States)

    Haricharan, Svasti; Punturi, Nindo; Singh, Purba; Holloway, Kimberly R; Anurag, Meenakshi; Schmelz, Jacob; Schmidt, Cheryl; Lei, Jonathan T; Suman, Vera; Hunt, Kelly; Olson, John A; Hoog, Jeremy; Li, Shunqiang; Huang, Shixia; Edwards, Dean P; Kavuri, Shyam M; Bainbridge, Matthew N; Ma, Cynthia X; Ellis, Matthew J

    2017-10-01

    Significant endocrine therapy-resistant tumor proliferation is present in ≥20% of estrogen receptor-positive (ER + ) primary breast cancers and is associated with disease recurrence and death. Here, we uncover a link between intrinsic endocrine therapy resistance and dysregulation of the MutL mismatch repair (MMR) complex ( MLH1/3 , PMS1/2 ), and demonstrate a direct role for MutL complex loss in resistance to all classes of endocrine therapy. We find that MutL deficiency in ER + breast cancer abrogates CHK2-mediated inhibition of CDK4, a prerequisite for endocrine therapy responsiveness. Consequently, CDK4/6 inhibitors (CDK4/6i) remain effective in MutL-defective ER + breast cancer cells. These observations are supported by data from a clinical trial where a CDK4/6i was found to strongly inhibit aromatase inhibitor-resistant proliferation of MutL-defective tumors. These data suggest that diagnostic markers of MutL deficiency could be used to direct adjuvant CDK4/6i to a population of patients with breast cancer who exhibit marked resistance to the current standard of care. Significance: MutL deficiency in a subset of ER + primary tumors explains why CDK4/6 inhibition is effective against some de novo endocrine therapy-resistant tumors. Therefore, markers of MutL dysregulation could guide CDK4/6 inhibitor use in the adjuvant setting, where the risk benefit ratio for untargeted therapeutic intervention is narrow. Cancer Discov; 7(10); 1168-83. ©2017 AACR. This article is highlighted in the In This Issue feature, p. 1047 . ©2017 American Association for Cancer Research.

  18. Multilayer optics for monochromatic high-resolution X-ray imaging diagnostic in a broad photon energy range from 2 keV to 22 keV

    International Nuclear Information System (INIS)

    Troussel, Ph.; Dennetiere, D.; Maroni, R.; Høghøj, P.; Hedacq, S.; Cibik, L.; Krumrey, M.

    2014-01-01

    The “Commissariat à l’énergie atomique et aux énergies alternatives” (CEA) studies and designs advanced X-ray diagnostics to probe dense plasmas produced at the future Laser MegaJoule (LMJ) facility. Mainly for X-ray imaging with high spatial resolution, different types of multilayer mirrors were developed to provide broadband X-ray reflectance at grazing incidence. These coatings are deposited on two toroidal mirror substrates that are then mounted into a Wolter-type geometry (working at a grazing angle of 0.45°) to realize an X-ray microscope. Non-periodic (depth graded) W/Si multilayer can be used in the broad photon energy range from 2 keV to 22 keV. A third flat mirror can be added for the spectral selection of the microscope. This mirror is coated with a Mo/Si multilayer for which the d-spacing varies in the longitudinal direction to satisfy the Bragg condition within the angular acceptance of the microscope and also to compensate the angular dispersion due to the field of the microscope. We present a study of such a so-called Göbel mirror which was optimized for photon energy of 10.35 keV. The three mirrors were coated using magnetron sputtering technology by Xenocs SA. The reflectance in the entire photon energy range was determined in the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the synchrotron radiation facility BESSY II in Berlin

  19. Multilayer optics for monochromatic high-resolution X-ray imaging diagnostic in a broad photon energy range from 2 keV to 22 keV

    Energy Technology Data Exchange (ETDEWEB)

    Troussel, Ph., E-mail: philippe.troussel@cea.fr [CEA, DAM, DIF, F-91297 Arpajon (France); Dennetiere, D. [Synchrotron Soleil, L’orme des Merisiers, 91190 Saint-Aubin (France); Maroni, R. [CEA, DAM, DIF, F-91297 Arpajon (France); Høghøj, P.; Hedacq, S. [Xenocs SA, 19, rue François Blumet, F-38360 Sassenage (France); Cibik, L.; Krumrey, M. [Physikalisch-Technische Bundesanstalt (PTB), Abbestr. 2-12, 10587 Berlin (Germany)

    2014-12-11

    The “Commissariat à l’énergie atomique et aux énergies alternatives” (CEA) studies and designs advanced X-ray diagnostics to probe dense plasmas produced at the future Laser MegaJoule (LMJ) facility. Mainly for X-ray imaging with high spatial resolution, different types of multilayer mirrors were developed to provide broadband X-ray reflectance at grazing incidence. These coatings are deposited on two toroidal mirror substrates that are then mounted into a Wolter-type geometry (working at a grazing angle of 0.45°) to realize an X-ray microscope. Non-periodic (depth graded) W/Si multilayer can be used in the broad photon energy range from 2 keV to 22 keV. A third flat mirror can be added for the spectral selection of the microscope. This mirror is coated with a Mo/Si multilayer for which the d-spacing varies in the longitudinal direction to satisfy the Bragg condition within the angular acceptance of the microscope and also to compensate the angular dispersion due to the field of the microscope. We present a study of such a so-called Göbel mirror which was optimized for photon energy of 10.35 keV. The three mirrors were coated using magnetron sputtering technology by Xenocs SA. The reflectance in the entire photon energy range was determined in the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the synchrotron radiation facility BESSY II in Berlin.

  20. Design of an accelerator tube for 500 keV/10 mA electron beam machine

    International Nuclear Information System (INIS)

    Maksum, W.; Sudjatmoko; Suprapto

    1999-01-01

    A design of an accelerator tube for 500 keV/10 mA electron beam machine was carried out. This tube was used for focussing and accelerating of electron beams. The tube was designed to consist of some electrodes insulator tubes and a voltage divider. The electrodes was made of stainless steel due to its low outgassing constant and stainless, the insulator was made of pyrex glass due to its low outgassing constant and high temperature proof and the voltage divider was made of high-ohmic resistors used for accelerating potential distribution at the electrodes. The stainless steel electrodes were comic shaped 3 mm thick with 134 mm inlet diameter and 60 mm outlet diameter. The number for this electrodes was 34 so that the potential gap between adjacent electrodes not exceed 15 kV. The insulators were 5 mm thick, 150 mm outer diameter, 140 mm inner diameter and 32 mm long. The insulators were joined to the electrodes by using an epoxy form an accelerator tube. The designed accelerator tube could be constructed and operated at a vacuum of 10 -6 torr and accelerated electron beam at an energy of 500 keV. (author)

  1. IC 3639 - A New Bona Fide Compton-Thick AGN Unveiled By NuSTAR

    Science.gov (United States)

    Boorman, Peter G.; Gandhi, P.; Alexander, D. M.; Annuar, A.; Ballantyne, D. R.; Bauer, F.; Boggs, S. E.; Brandt, W. N.; Brightman, M.; Christensen, F. E.; hide

    2016-01-01

    We analyze high-quality NuSTAR observations of the local (z = 0.011) Seyfert 2 active galactic nucleus (AGN) IC 3639, in conjunction with archival Suzaku and Chandra data. This provides the first broadband X-ray spectral analysis of the source, spanning nearly two decades in energy (0.5-30 keV). Previous X-ray observations of the source below 10 keV indicated strong reflection/obscuration on the basis of a pronounced iron fluorescence line at 6.4 keV. The hard X-ray energy coverage of NuSTAR, together with self-consistent toroidal reprocessing models, enables direct broadband constraints on the obscuring column density of the source. We find the source to be heavily Compton-thick (CTK) with an obscuring column in excess of 3.6 x 10(exp 24) cm(exp -2), unconstrained at the upper end. We further find an intrinsic 2-10 keV luminosity of log(sub 10) (L(sub 2-10 keV) [erg s(exp -1)])= 43.4(+0.6/-1.1) to 90% confidence, almost 400 times the observed flux, and consistent with various multiwavelength diagnostics. Such a high ratio of intrinsic to observed flux, in addition to an Fe-K(alpha) fluorescence line equivalent width exceeding 2 keV, is extreme among known bona fide CTK AGNs, which we suggest are both due to the high level of obscuration present around IC 3639. Our study demonstrates that broadband spectroscopic modeling with NuSTAR enables large corrections for obscuration to be carried out robustly and emphasizes the need for improved modeling of AGN tori showing intense iron fluorescence.

  2. 10 K gate I(2)L and 1 K component analog compatible bipolar VLSI technology - HIT-2

    Science.gov (United States)

    Washio, K.; Watanabe, T.; Okabe, T.; Horie, N.

    1985-02-01

    An advanced analog/digital bipolar VLSI technology that combines on the same chip 2-ns 10 K I(2)L gates with 1 K analog devices is proposed. The new technology, called high-density integration technology-2, is based on a new structure concept that consists of three major techniques: shallow grooved-isolation, I(2)L active layer etching, and I(2)L current gain increase. I(2)L circuits with 80-MHz maximum toggle frequency have developed compatibly with n-p-n transistors having a BV(CE0) of more than 10 V and an f(T) of 5 GHz, and lateral p-n-p transistors having an f(T) of 150 MHz.

  3. Elastic and inelastic processes in He/sup +/-H/sub 2/ collisions between 2 and 30 keV

    Energy Technology Data Exchange (ETDEWEB)

    Bergnes, C.; Bordenave-Montesquieu, D.; Boutonnet, A.; Nouet, P.; Dagnac, R.

    1986-10-14

    The elastic and inelastic processes have been studied for scattering of He/sup +/ ions by H/sub 2/ molecules between 2 and 30 keV in the angular range from 10' to 3/sup 0/ by an energy loss technique. The analysis of elastic energy loss against E/sub 0/theta/sup 2/ shows that the incident ion is scattered by the entire molecule at low energies whereas at high energies it is scattered by only one atom in the target. Comparison of the relative probabilities of the various excitation processes with the isoelectronic system He/sup +/-He demonstrates the different behaviours of a molecular target in the excitation mechanism.

  4. Resonance strength of the 1175 keV resonance in 6Li(α, γ)10B

    International Nuclear Information System (INIS)

    Spear, R.H.; Switkowski, Z.E.; Kennedy, D.L.; Heggie, J.C.P.

    1979-01-01

    The resonance strength of the 1175-keV resonance in 6 Li(α, γ) 10 B has been remeasured using a Ge(Li) detector. The result obtained is 0.40+-0.06 eV. This is in good agreement with previous measurements using NaI(T1) detectors, provided that the earlier results are multiplied by the factor 6/10 to convert them to the centre-of-mass system. Some of the consequences which arise from the failure of previous workers to make this correction before evaluating the significance of their results are discussed

  5. Power supply for the LBL 40 keV neutral beam source

    International Nuclear Information System (INIS)

    Baker, W.R.; Fitzgerald, M.L.; Honey, V.J.

    1975-11-01

    A 20 keV, 50 Amp, 10 millisec pulse D 0 Neutral Beam Source at the Lawrence Berkeley Laboratory that serves as the prototype for 12 similar sources now in operation on the 2XIIB Mirror Machine at the Lawrence Livermore Laboratory has been recently upgraded to operate at 40 keV. The system of electronically regulated and controlled power supplies that drive the Source is described

  6. Neutron fluence and energy reconstruction with the IRSN recoil detector μ-TPC at 27 keV, 144 keV and 565 keV

    Energy Technology Data Exchange (ETDEWEB)

    Maire, D.; Lebreton, L.; Richer, J.P. [IRSN, PRP-HOM, SDE, LMDN, 13115 Saint Paul-Lez-Durance (France); Bosson, G.; Bourrion, O.; Guillaudin, O.; Riffard, Q.; Santos, D. [CNRS/IN2P3-UJF-INPG, LPSC, 38000 Grenoble (France)

    2015-07-01

    The French Institute for Radioprotection and Nuclear Safety (IRSN), associated to the French Metrology Institute (LNE), is developing a time projection chamber using a Micromegas anode: μ-TPC. This work is carried out in collaboration with the Laboratory of Subatomic Physics and Cosmology (LPSC). The aim is to characterize with a primary procedure the energy distribution of neutron fluence in the energy range 8 keV - 1 MeV. The time projection chambers are gaseous detectors, which are able to measure charged particles energy and to reconstruct their track if a pixelated anode is used. In our case, the gas is used as a (n, p) converter in order to detect neutrons down to few keV. Coming from elastic collisions with neutrons, recoil protons lose a part of their kinetic energy by ionizing the gas. The ionization electrons are drifted toward a pixelated anode (2D projection), read at 50 MHz by a self-triggered electronic system to obtain the third track dimension. The neutron energy is reconstructed event by event thanks to proton scattering angle and proton energy measurements. The scattering angle is deduced from the 3D track. The proton energy is obtained by charge collection measurements, knowing the ionization quenching factor (i.e. the part of proton kinetic energy lost by ionizing the gas). The fluence is calculated thanks to the detected events number and the simulated detector response. The μ-TPC is a new reliable detector which enables to measure energy distribution of the neutron fluence without deconvolution or neutron calibration contrary to usual gaseous counters. The μ-TPC is still being developed and measurements have been carried out at the AMANDE facility, with neutrons energies going from 8 keV to 565 keV. After the context and the μ-TPC working principle presentation, measurements of the neutron energy and fluence at 27.2 keV, 144 keV and 565 keV are shown and compared to the complete detector simulation. This work shows the first direct

  7. Measured energy dependence of L-shell photoelectric cross sections of lead in the energy region 17-50 keV

    Energy Technology Data Exchange (ETDEWEB)

    Arora, S K; Allawadhi, K L; Sood, B S [Punjabi Univ., Patiala (India). Nuclear Science Labs.

    1980-08-28

    The energy dependence of L-shell photoelectric cross sections for lead in the energy region 17-50 keV has been investigated. The method utilises external conversion x-rays as the source of photons and it yields relative rather than absolute cross sections, but is simpler and more accurate. The results show fairly good agreement with theory.

  8. Radiation blistering of Nb implanted sequentially with helium ions of different energies (3-500 keV)

    International Nuclear Information System (INIS)

    Guseva, M.I.; Gusev, V.; Krasulin, U.L.; Martinenko, U.V.; Das, S.K.; Kaminsky, M.S.

    1976-01-01

    Cold rolled, polycrystalline niobium samples were irradiated at room temperature with 4 He + ions sequentially at 14 different energies over an energy range from 3 keV--500 keV in steps of 50 keV. The dose for each energy was chosen to give an approximately uniform concentration of helium between the implant depths corresponding to 3 keV and 500 keV. In one set of experiments the irradiations were started at the Kurchatov Institute with 3 keV 4 He + ions and extended up to 80 keV in several steps. Subsequently, the same target area was irradiated with 4 He + ions at Argonne National Laboratory (ANL) starting at 100 keV and increased to 500 keV in steps of 50 keV. Another set of irradiations were started at ANL with 500 keV 4 He + ions and continued with decreasing ion energies to 100 keV. Subsequently, the same area was irradiated at the Kurchatov Institute starting at 80 keV and continued with decreasing ion energies to 3 keV. Both sets of irradiations were completed for two different total doses, 0.5 C cm -2 and 1.0 C cm -2

  9. The periodic table and the intrinsic barrier in s(n)2 reactions.

    Science.gov (United States)

    Yi, Ren; Basch, Harold; Hoz, Shmaryahu

    2002-08-23

    The identity S(N)2 reactions on nitrogen (see eq 3) with nucleophiles having the general structure H(n)()X(-) where X belongs to the group of nonmetallic elements which do not border the line separating them from the metallic elements (X = F, Cl, Br, I, O, S, Se, N, P, and C) were studied at the G2+ level. The results show that, similarly to the previously observed phenomenon for S(N)2 reaction on carbon (J. Am. Chem. Soc. 1999, 121, 7724), the Periodic Table, through the valence of the element X, controls the intrinsic barrier for the reaction. The average intrinsic barriers obtained for nitrogen substrates were 20, 27, 39, and 57 kcal/mol for the mono-, di-, tri-, and tetravalent X's, respectively. It is also concluded that the intrinsic barriers are similar for N- and C-based substrates and dimethyl substitution on both raises the intrinsic barrier by ca. 10 kcal/mol.

  10. 3–10 keV Xe+ ion beam machining of ultra low thermal expansion glasses for EUVL projection optics: Evaluation of surface roughness

    International Nuclear Information System (INIS)

    Morikawa, K.; Kamijo, K.; Morijiri, K.; Pahlovy, S.A.; Aikawa, N.; Miyamoto, I.

    2012-01-01

    In order to obtain surface figure error of 0.15 nm rms and surface roughness (R rms ) of 0.12 nm rms for aspherical substrates in EUVL tools, ion beam figuring may be adopted to final surface figure error correction of aspherical substrates. During figure error correction, machined surface of the substrate becomes rougher than the pre-finished one. Therefore, we investigated the machined depth and ion energy dependences of R rms (measured by an AFM) of substrates machined by 3–10 keV Xe + ion beam, and compared them with the results obtained for Ar + ion beam. Result shows that the R rms s of CLEARCERAM®-Z, Zerodur® and ULE® substrates machined to the depth of 50 nm by 3–10 keV Xe + ion beam at the normal ion incidence angle become approximately 0.25, 0.28 and 0.15 nm rms, respectively. Those values are larger than the pre-finished substrates (0.07–0.09 nm rms), but smaller than that (0.60 nm rms for CLEARCERAM®-Z, 0.61 nm rms for Zerodur® and 0.18 nm rms for ULE®) of the substrates machined by Ar + ion beam. Moreover, the R rms s merely increase with increasing ion energy. The R rms s of the ULE® substrate machined by 3–10 keV Xe + ion beam rapidly increase with increasing machined depth, then saturate at machined depth of 10–50 nm. The saturated values of the R rms s are 0.12 and 0.15 nm rms for 3 and 10 keV Xe + ion beam respectively. We suggest that the 3 keV Xe + ion beam machining can be applicable for final shape correction of ULE® substrates for EUVL projection optics in association with considering further ultra smoothing process such as Si deposition or low energy ion beam smoothing.

  11. Single-electron capture into Ar+ excited states in Ar2 + Na collision below 12 keV, 1

    International Nuclear Information System (INIS)

    Matsumoto, Atsushi; Tsurubuchi, Seiji; Okuno, Kazuhiko; Ohtani, Shunsuke; Iwai, Tsuruji.

    1979-08-01

    Emission spectra between 2800 and 6000 A have been observed at the ionic energies from 0.2 to 12 keV. Absolute measurements of emission cross-sections have been made for the emission lines coming from ArII excited states at 4 and 8 keV with a crossed-beam technique. Processes of single-electron capture into the ArII 4p- and 4p'-states, with exothermicity of a few eV, take place dominantly (--10 15 cm 2 ), while the endothermic processes producing ArII in the 4d- and 5s-states occur with small cross-sections. Sum of the cross-sections for electron capture into the excited states observed is comparable with the total single-electron capture cross-section estimated from attenuation measurements of ion currents. Possible errors and uncertainties are discussed. (author)

  12. Single-electron capture into Ar+ excited states in Ar2++Na collision below 12 keV, 1

    International Nuclear Information System (INIS)

    Matsumoto, Atsushi; Tsurubuchi, Seiji; Iwai, Tsuruji; Ohtani, Shunsuke; Okuno, Kazuhiko

    1980-01-01

    Emission spectra between 2800 and 6000 A have been observed at the ionic energies from 0.2 to 12 keV. Absolute measurements of emission cross-sections have been made for the emission lines coming from ArII excited states at 4 and 8 keV with a crossed-beam technique. Processes of single-electron capture into the ArII 4p- and 4p'-states, with exothermicity of a few eV, take place dominantly (--10 -15 cm 2 ), while the endothermic processes producing ArII in the 4d- and 5s-states occur with small cross-sections. Sum of the cross-sections for electron capture into the excited states observed is comparable with the total single-electron capture cross-section estimated from attenuation measurements of ion currents. Possible errors and uncertainties are discussed. (author)

  13. Electron scattering by Ne, Ar and Kr at intermediate and high energies, 0.5-10 keV

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, G.; Roteta, M.; Manero, F. [Centro de Investigaciones Energeticas Medioambientales y Tecnologicas (CIEMAT), Departamento de Fusion y Particulas Elementales, Madrid (Spain); Blanco, F. [Universidad Complutense de Madrid, Facultad de Fisica, Departamento de Fisica Atomica Molecular y Nuclear, Madrid (Spain); Williart, A. [Universidad Nacional de Educacion a Distancia, Facultad de Ciencias, Departamento de Fisica de los Materiales, Madrid (Spain)

    1999-04-28

    Semi-empirical total cross sections for electron scattering of noble gases (Ne, Ar and Kr) in the energy range 0.5-10 keV have been obtained by combining transmission-beam measurements for impact energies up to 6 keV with an asymptotic behaviour at higher energies according to the Born-Bethe approximation. The influence of the forward electron scattering on the experimental system has been evaluated by means of a Monte Carlo electron transport simulation. Theoretical values have also been obtained by applying the Born approximation in the case of inelastic processes and by means of an atomic scattering potential for the elastic part. The results of these calculations show an excellent agreement with the semi-empirical values in the above-mentioned energy range. (author)

  14. Power scaling of the Xe(L) amplifier at {lambda} {approx} 2.8 A into the petawatt regime

    Energy Technology Data Exchange (ETDEWEB)

    Borisov, Alex B; Racz, Ervin; Khan, Shahab F; Poopalasingam, Sankar; McCorkindale, John C; Zhao Ji; Boguta, John; Longworth, James W; Rhodes, Charles K [Laboratory for x-ray Microimaging and Bioinformatics, Department of Physics, University of Illinois at Chicago, Chicago, IL 60607-7059 (United States)

    2010-01-14

    Single-pulse and time-integrated spectral measurements of the characteristics of the Xe(L) amplifier at {lambda} {approx} 2.8 A indicate an efficiency of energy extraction of {approx}30% over a bandwidth of {approx}500 eV. These observations, together with data from prior studies, provide a basis for estimating a corresponding set of scaling limits for a laboratory sized {approx}4.5 keV Xe(L) system. Specifically, they are a peak power P{sub x} {approx} 6.0 PW, an unfocused peak intensity I{sub x} {approx} 3.4 x 10{sup 21} W cm{sup -2}, peak brightness figures corresponding to B {approx} 4.1 x 10{sup 34} photons s{sup -1} mm{sup -2} mrad{sup -2} (0.1% bandwidth){sup -1} and P{sub x}/{lambda}{sup 2} {approx} 7.6 x 10{sup 30} W cm{sup -2} sr{sup -1}, and an x-ray pulse length {tau}{sub x} {approx} 5-10 as.

  15. Measurement of 24.3 keV activation cross sections with the iron filter technique

    International Nuclear Information System (INIS)

    Rimawi, K.; Chrien, R.E.

    1975-01-01

    By using high-resolution detection techniques, intensities of specific activation lines from 197 Au(n,gamma), 238 U(n,gamma), 127 I(n,gamma), and 115 In(n,gamma) [54 min + 2.2 sec] were recorded, by using the BNL HFBR iron-filtered neutron beam. From a com- parison with the reaction 10 B(n,αgamma), cross sections at 24.3 keV were determined. (24.3 keV neutron activation cross sections, relative 10 B standard). (4 figures) (U.S.)

  16. Correlation between blister skin thickness, the maximum in the damage-energy distribution, and projected ranges of helium ions in Nb for the energy range 10 to 1500 keV

    International Nuclear Information System (INIS)

    St-Jacques, R.G.; Martel, J.G.; Terreault, B.; Veilleux, G.; Das, S.K.; Kaminsky, M.; Fenske, G.

    1976-01-01

    The skin thickness of blisters formed on polycrystalline niobium by 4 He + irradiation at room temperature for energies from 15 to 80 keV have been measured. Similar measurements were conducted for 10 keV 4 He + irradiation at 500 0 C to increase blister exfoliation, and thereby allow examination of a larger number of blister skins. For energies smaller than 100 keV the skin thicknesses are compared with the projected range and the damage-energy distributions constructed from moments interpolated from Winterbon's tabulated values. For energies of 10 and 15 keV the projected ranges and damage-energy distributions have also been computed with a Monte Carlo program. For energies larger than 100 keV the projected ranges of 4 He + in Nb were calculated using either Brice's formalism or the one given by Schiott. The thicknesses for 60 and 80 keV, and those reported earlier for 100 to 1500 keV correlate well with calculated projected ranges. For energies lower than 60 keV the measured thicknesses are larger than the calculated ranges

  17. FLUKA and PENELOPE simulations of 10keV to 10MeV photons in LYSO and soft tissue

    CERN Document Server

    Chin, M P W; Fassò, A; Ferrari, A; Ortega, P G; Sala, P R

    2014-01-01

    Monte Carlo simulations of electromagnetic particle interactions and transport by FLUKA and PENELOPE were compared. 10 key to 10 MeV incident photon beams impinged a LYSO crystal and a soft-tissue phantom. Central-axis as well as off-axis depth doses agreed within 1 s.d.; no systematic under- or overestimate of the pulse height spectra was observed from 100 keV to 10 MeV for both materials, agreement was within 5\\%. Simulation of photon and electron transport and interactions at this level of precision and reliability is of significant impact, for instance, on treatment monitoring of hadrontherapy where a code like FLUKA is needed to simulate the full suite of particles and interactions (not just electromagnetic). At the interaction-by-interaction level, apart from known differences in condensed history techniques, two-quanta positron annihilation at rest was found to differ between the two codes. PENELOPE produced a 511 key sharp line, whereas FLUKA produced visible acolinearity, a feature recently implemen...

  18. Weak hard X-ray emission from two broad absorption line quasars observed with NuSTAR: Compton-thick absorption or intrinsic X-ray weakness?

    DEFF Research Database (Denmark)

    Luo, B.; Brandt, W. N.; Alexander, D. M.

    2013-01-01

    are not significantly absorbed (NH ≲ 1024 cm-2). However, both BAL quasars are only detected in the softer NuSTAR bands (e.g., 4-20 keV) but not in its harder bands (e.g., 20-30 keV), suggesting that either the shielding gas is highly Compton-thick or the two targets are intrinsically X-ray weak. We constrain...... likely explanation. We also discuss the intrinsic X-ray weakness scenario based on a coronal-quenching model relevant to the shielding gas and disk wind of BAL quasars. Motivated by our NuSTAR results, we perform a Chandra stacking analysis with the Large Bright Quasar Survey BAL quasar sample and place...

  19. Experimental Set-up for Irradiation of Solid H2 and D2 with Charged Particles of keV Energies

    DEFF Research Database (Denmark)

    Sørensen, H.

    1976-01-01

    crystal film thickness monitor. The target plate, which can be heated so that films are removable by evaporation, may be used both as a calorimeter and as a beam current collector. Methods for measurement of secondary electron emission coefficients were developed, and preliminary measurements were made...... with electrons and hydrogen ions. For electron bombardment, the secondary electron emission coefficient of solid deuterium was much smaller than one. It was shown possible to use the set-up to study beam desorption of very thin films. Furthermore the set-up could be used for measuring the energy......An experimental facility was built where films of solid deuterium (and hydrogen) may be made with known thickness and irradiated with pulsed beams of electrons (up to 3 keV) and light ions (up to 10 keV). Films are made on a target plate held at 2.5–3 K. Film growth rate is calibrated with a quartz...

  20. High-energy behavior of the double photoionization of helium from 2 to 12 keV

    International Nuclear Information System (INIS)

    Levin, J.C.; Sellin, I.A.; Johnson, B.M.; Lindle, D.W.; Miller, R.D.; Berrah, N.; Azuma, Y.; Berry, H.G.; Lee, D.

    1993-01-01

    We report the ratio of double-to-single photoionization of He at several photon energies from 2 to 12 keV. By time-of-flight methods, we find a ratio consistent with an asymptote at 1.5%±0.2%, essentially reached by hν∼4 keV. Fair agreement is obtained with older shake calculations of Byron and Joachain [Phys. Rev. 164, 1 (1967)], of Aberg [Phys. Rev. A 2, 1726 (1970)], and with recent many-body perturbation theory (MBPT) of Ishihara, Hino, and McGuire [Phys. Rev. A 44, 6980 (1991)]. The result lies below earlier MPBT calculations by Amusia et al. [J. Phys. B 8, 1248 (1975)] (2.3%), and well above semiempirical predictions of Samson [Phys. Rev. Lett. 65, 2861 (1990)], who expects no asymptote and predicts σ(He 2+ )/σ(He + )=0.3% at 12 keV

  1. Slowing down of 100 keV antiprotons in Al foils

    Science.gov (United States)

    Nordlund, K.

    2018-03-01

    Using energy degrading foils to slow down antiprotons is of interest for producing antihydrogen atoms. I consider here the slowing down of 100 keV antiprotons, that will be produced in the ELENA storage ring under construction at CERN, to energies below 10 keV. At these low energies, they are suitable for efficient antihydrogen production. I simulate the antihydrogen motion and slowing down in Al foils using a recently developed molecular dynamics approach. The results show that the optimal Al foil thickness for slowing down the antiprotons to below 5 keV is 910 nm, and to below 10 keV is 840 nm. Also the lateral spreading of the transmitted antiprotons is reported and the uncertainties discussed.

  2. A Monte Carlo computer code for evaluating energy loss of 10 keV to 10 MeV ions in amorphous silicon materials

    International Nuclear Information System (INIS)

    Erramli, H.; Elbounagui, O.; Misdaq, M.A.; Merzouki, A.

    2007-01-01

    The basic concepts of a computer simulation code for determining the energy loss of ions in the 10 keV to 10 MeV energy range in amorphous silicon materials were presented and discussed. Data obtained were found in good agreement with those obtained by using a SRIM programme. Electronic and nuclear energy losses were evaluated. Variation of the energy loss as a function of the incident ion energy were studied. This new computer code is a good tool for evaluating stopping powers of various materials for light and heavy ions

  3. Double capture in the O8+ + He collision investigated by electron spectroscopy (80 keV, 10 deg)

    International Nuclear Information System (INIS)

    Moretto-Capelle, P.; Benoit-Cattin, P.; Bordenave-Montesquieu, A.; Boudjema, M.; Gleizes, A.; Dousson, S.; Hitz, D.

    1989-01-01

    Double capture into (3,n) autoionising states of O 6+ is observed in the O 8+ + He collision system by electron spectroscopy at 80 keV, 10 0 . A comparison of the experimental results with theoretical positions and lifetimes allows the (3,3) states as well as three groups of (3,4) states to be identified. The present experimental findings are compared with earlier data for the N 7+ + He and Ne 8+ (1s 2 ) + He systems. The influence of the core of the multicharged ion is studied by examining the O 8+ and Ne 8+ (1s 2 ) results. The total double capture cross section is found to be large and it is compared with available experimental and theoretical data. (author)

  4. Characteristic 8 keV X rays possess radiobiological properties of higher-LET radiation.

    Science.gov (United States)

    Shridhar, Ravi; Estabrook, William; Yudelev, Mark; Rakowski, Joseph; Burmeister, Jay; Wilson, George D; Joiner, Michael C

    2010-03-01

    Electronic brachytherapy systems are being developed that can deliver X rays of varying energy depending on the material of a secondary target. A copper target produces characteristic 8 keV X rays. Our aim was to determine whether 8 keV X rays might deliver greater biological effectiveness than megavoltage photons. Cells of the U251 human glioma cell line were used to compare the biological effects of 8 keV X rays and (60)Co gamma rays in terms of relative biological effectiveness (RBE), oxygen enhancement ratio (OER), and DNA damage. The RBE at 50% and 10% survival was 2.6 and 1.9, respectively. At 50% survival, the OER for cells treated with 8 keV X rays was 1.6 compared with 3.0 for (60)Co gamma rays. The numbers of H2AX foci per Gy after treatment with 8 keV X rays and (60)Co gamma rays were similar; however, the size of the foci generated at 8 keV was significantly larger, possibly indicating more complex DNA damage. The mean area of H2AX foci generated by 8 keV X rays was 0.785 microm(2) (95% CI: 0.756-0.814) compared with 0.491 microm(2) (95% CI: 0.462-0.520) for (60)Co gamma rays (P X rays produce two to three times the biological effectiveness of megavoltage photons, with a radiobiological profile similar to higher-LET radiations.

  5. 100 keV 10-B+ implantation into poly-(di-n-hexyl silane), (PDHSi)

    International Nuclear Information System (INIS)

    Fink, D.; Mueller, M.; Behar, M.; Papaleo, R.M.

    2006-01-01

    100 keV 10 B + ions were implanted into poly-(di-n-hexyl silane) in different directions at a fluence of 1 x 10 14 cm -2 , and their depth distribution was determined by means of the neutron depth profiling technique. In no case were the projectile ions found to come to rest according to their predicted range profiles. Instead, they are always found to undergo considerable long-range migration. During the irradiation process this motion appears to be radiation-enhanced, and during the subsequent annealing steps one appears to deal with regular thermal diffusion. The implant redistribution is always found to be governed strongly by the self-created damage, insofar as both electronic and nuclear defects in the polymer act as trapping centers. Their population ratio is modified by thermal annealing. The as-implanted redistribution shows a pronounced directional dependence, which essentially is a consequence of the spatial distributions of the electronic and nuclear damage. The changes of the nuclear defect distribution during thermal annealing are studied by a specially developed tomographic method. It is found that boron is preferentially trapped along the irradiation direction, exhibiting quite pronounced prolate (i.e. cigar-like) distributions. This shape is almost unaffected by thermal annealing. (orig.)

  6. Neutron capture resonances in 56Fe and 58Fe in the energy range from 10 to 100 keV

    International Nuclear Information System (INIS)

    Kaeppeler, F.; Wisshak, K.; Hong, L.D.

    1982-11-01

    The neutron capture cross section of 56 Fe and 58 Fe has been measured in the energy range from 10 to 250 keV relative to the gold standard. A pulsed 3 MV Van de Graaff accelerator and the 7 Li(p, n) reaction served as a neutron source. Capture gamma rays were detected by two C 6 D 6 detectors, which were operated in coincidence and anticoincidence mode. Two-dimensional data acquisition allowed to apply the pulse height weighting technique off-line. The samples were located at a flight path of 60 cm. The total time resolution was 1.2 ns thus allowing for an energy resolution of 2 ns/m. The experimental set-up was optimized with respect to low background and low neutron sensitivity. The additional flight path of 4 cm from the sample to the detector was sufficient to discriminate capture of sample scattered neutrons by the additional time of flight. In this way reliable results were obtained even for the strong s-wave resonances of both isotopes. The experimental capture yield was analyzed with the FANAC code. The energy resolution allowed to extract resonance parameters in the energy range from 10 to 100 keV. The individual systematic uncertainties of the experimental method are discussed in detail. They were found to range between 5 and 10% while the statistical uncertainty is 3-5% for most of the resonances. A comparison to the results of other authors exhibits in case of 56 Fe systematic differences of 7-11%. For 58 Fe the present results differ up to 50% from the only other measurement for this isotope. (orig.) [de

  7. Uranium enrichment measurements without calibration using gamma rays above 100 keV

    International Nuclear Information System (INIS)

    Ruhter, Wayne D.; Lanier, Robert G.; Hayden, Catherine F.

    2001-01-01

    Full text: The verification of UF6 shipping cylinders is an important activity in routine safeguards inspections. Current measurement methods using either sodium-iodide or high-purity germanium detectors requires calibrations that are not always appropriate for field measurements, because of changes in geometry or container wall thickness. The introduction of the MGAU code demonstrated the usefulness of intrinsically calibrated measurements for inspections. MGAU uses the 100-keV region of the uranium gamma-ray spectrum. The thick walls of UF6 shipping cylinders preclude the routine use of MGAU for these measurements. We have developed a uranium enrichment measurement method for measurements using high- purity germanium detectors, which do not require calibration and uses uranium gamma rays above 100 keV. The method uses seven gamma rays from U-235 and U-238 to determine their relative detection efficiency intrinsically and with an additional gamma ray from U-234 the relative abundance of these three uranium isotopes. The method uses a function that describes the basic physical processes that predominately determine the relative detection efficiency curve, These are the detector efficiency, the absorption by the cylinder wall, and the self-absorption by the UF6 contents. We will describe this model and its performance on various uranium materials and detector types. (author)

  8. Gamma radiation in space and in the atmosphere; Rayonnement gamma dans l'espace et dans l'atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    Rocchia, R. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1966-07-01

    We have shown that the {gamma} radiation existing in the atmosphere is caused mainly by the Bremsstrahlung of the electrons of the electromagnetic cascades ({approx} 50 per cent of the measured radiation), by the 511 keV radiation produced by the annihilation of positrons created in cascades (8 per cent of the measured intensity) and by the Compton {gamma} degradation of this line (30 per cent of the measured intensity). The rest, slightly over 10 per cent, must be attributed to secondary causes such as the nuclear de-excitation {gamma} to the internal Bremsstrahlung of charged particles created in nuclear stars, and to charged particles crossing our detector, since the latter was not fitted with a device for rejecting these particles. Experiments carried out in rockets at Colomb-Bechar confirm these results and have made it possible to detect and measure a primary {gamma} radiation having an intensity of {approx} 2 {gamma} cm{sup 2} s{sup -1} above 100 keV. The primary spectrum obeys an approximate E{sup -2} law. (author) [French] Nous avons montre que le rayonnement {gamma} existant dans l'atmosphere est provoque principalement por le bremsstrohlung des electrons des cascades electromagnetiques ({approx} 50 pour cent du rayonnement mesure), au rayonnement 511 keV provoque par l'annihilation des positrons crees dans les cascades (8 pour cent de l'intensite mesuree) et aux {gamma} de degradation Compton de cette raie (30 pour cent de l'intensite mesuree). Le reste, soit un peu plus de 10 pour cent, doit etre attribue a des causes secondaires telles que les {gamma} de desexcitation nucleaire, le bremsstrahlung interne des particules chargees creees dans les etoiles nucleaires, et aux particules chargees traversant notre detecteur car celui-ci ne comportait pas de dispositif de rejet de ces particules. Les experiences faites en fusees a Colomb-Bechar ont confirme ces resultats et permis de detecter et mesurer un rayonnement {gamma} primaire dont l

  9. Global gyrokinetic simulations of intrinsic rotation in ASDEX Upgrade Ohmic L-mode plasmas

    Science.gov (United States)

    Hornsby, W. A.; Angioni, C.; Lu, Z. X.; Fable, E.; Erofeev, I.; McDermott, R.; Medvedeva, A.; Lebschy, A.; Peeters, A. G.; The ASDEX Upgrade Team

    2018-05-01

    Non-linear, radially global, turbulence simulations of ASDEX Upgrade (AUG) plasmas are performed and the nonlinear generated intrinsic flow shows agreement with the intrinsic flow gradients measured in the core of Ohmic L-mode plasmas at nominal parameters. Simulations utilising the kinetic electron model show hollow intrinsic flow profiles as seen in a predominant number of experiments performed at similar plasma parameters. In addition, significantly larger flow gradients are seen than in a previous flux-tube analysis (Hornsby et al 2017 Nucl. Fusion 57 046008). Adiabatic electron model simulations can show a flow profile with opposing sign in the gradient with respect to a kinetic electron simulation, implying a reversal in the sign of the residual stress due to kinetic electrons. The shaping of the intrinsic flow is strongly determined by the density gradient profile. The sensitivity of the residual stress to variations in density profile curvature is calculated and seen to be significantly stronger than to neoclassical flows (Hornsby et al 2017 Nucl. Fusion 57 046008). This variation is strong enough on its own to explain the large variations in the intrinsic flow gradients seen in some AUG experiments. Analysis of the symmetry breaking properties of the turbulence shows that profile shearing is the dominant mechanism in producing a finite parallel wave-number, with turbulence gradient effects contributing a smaller portion of the parallel wave-vector.

  10. Ribosomal protein L10(L12)4 autoregulates expression of the Bacillus subtilis rplJL operon by a transcription attenuation mechanism.

    Science.gov (United States)

    Yakhnin, Helen; Yakhnin, Alexander V; Babitzke, Paul

    2015-08-18

    Ribosomal protein genes are often controlled by autoregulatory mechanisms in which a protein encoded in the operon can either bind to newly synthesized rRNA during rapid growth or to a similar target in its mRNA during poor growth conditions. The rplJL operon encodes the ribosomal L10(L12)4 complex. In Escherichia coli L10(L12)4 represses its translation by binding to the rplJL leader transcript. We identified three RNA structures in the Bacillus subtilis rplJL leader transcript that function as an anti-antiterminator, antiterminator or intrinsic terminator. Expression studies with transcriptional and translational fusions indicated that L10(L12)4 represses rplJL expression at the transcriptional level. RNA binding studies demonstrated that L10(L12)4 stabilizes the anti-antiterminator structure, while in vitro transcription results indicated that L10(L12)4 promotes termination. Disruption of anti-antiterminator, antiterminator or terminator function by competitor oligonucleotides in vitro and by mutations in vivo demonstrated that each structure functions as predicted. Thus, rplJL expression is regulated by an autogenous transcription attenuation mechanism in which L10(L12)4 binding to the anti-antiterminator structure promotes termination. We also found that translation of a leader peptide increases rplJL expression, presumably by inhibiting Rho-dependent termination. Thus, the rplJL operon of B. subtilis is regulated by transcription attenuation and antitermination mechanisms. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.

  11. Autoionisation of N5+ (nln'l') with n = 2,3,4 and n' >= n measured by electron spectrometry in collisions of N7+ with He and H2, at 4.9 keV amu-1

    International Nuclear Information System (INIS)

    Bordenave-Montesquieu, A.; Benoit-Cattin, P.; Gleizes, A.; Marrakchi, A.I.; Dousson, S.; Hitz, D.

    1984-01-01

    a spectroscopic investigation of electrons coming from autoionising states N 5+ (nln'l'), with n=2,3,4 and n' >= n, of the fast ion has been made at 11.6 0 and 4.9 keV amu -1 . Only exothermic reactions are observed. It is shown that the ionisation potential of the target has a strong influence on the more probable values of n and n'. In N 7+ -He collisions, the n=3, n'=3 configurations are the more excited. In N 7+ -H 2 , the capture process is less selective since n=3, n' > 3 and also n=4, n' >= 4 configurations are strongly populated. In all these cases, the residual N 6+ ion is left in an excited state (n=2 or 3). The n=2, n' > 2 excitation probability is found to be much smaller for the two collisional systems. (author)

  12. Charge transfer processes in collisions of H+ ions with H2, D2, CO, CO2 CH4, C2H2, C2H6 and C3H8 molecules below 10 keV

    International Nuclear Information System (INIS)

    Kusakabe, T.; Buenker, R.J.; Kimura, M.

    2002-01-01

    Charge transfer processes resulting from collisions of H + ions with H 2 , D 2 , CO, CO 2 CH 4 , C 2 H 2 , C 2 H 6 and C 3 H 8 molecules have been investigated in the energy range of 0.2 to 4.0 keV experimentally and theoretically. The initial growth rate method was employed in the experiment for studying the dynamics and cross sections. Theoretical analysis based on a molecular-orbital expansion method for H 2 , D 2 , CO, CH 4 and C 2 H 2 targets was also carried out. The present results for the H 2 , CO and CO 2 molecules by H + impact are found to be in excellent accord with most of previous measurements above 1 keV, but they show some differences below this energy where our result displays a stronger energy-dependence. For CH 4 , C 2 H 2 , C 2 H 6 and C 3 H 8 targets, both experimental and theoretical results indicate that if one assumes vibrationally excited molecular ions (CH 4 + , C 2 H 2 + , C 2 H 6 + and C 3 H 8 + ) formed in the exit channel, then charge transfer processes sometimes become more favorable since these vibrationally excited fragments meet an accidental resonant condition. This is a clear indication of the role of vibrational excited states for charge transfer, and is an important realization for general understanding. (author)

  13. Anomalously high yield of doubly charged Si ions sputtered from cleaned Si surface by keV neutral Ar impact

    Energy Technology Data Exchange (ETDEWEB)

    Shinde, N.; Morita, K. E-mail: k-morita@mail.nucl.nagoya-u.ac.jp; Dhole, S.D.; Ishikawa, D

    2001-08-01

    The energy spectra of positively charged and neutral species ejected from the Si(1 1 1) surfaces by keV Ar impact have been measured by means of a combined technique of the time-of-flight (TOF) analysis with the multi-photon resonance ionization spectroscopy (MPRIS). It is shown that positively charged species of Si{sup +}, Si{sup 2+} and SiO{sup +} are ejected from the as-cleaned 7x7 surface by 11 keV Ar impact. It is also shown that Ar sputter cleaning of the as-cleaned 7x7 surface for 14 min at the flux of 2x10{sup 13}/cm{sup 2}s removes completely the oxygen impurity and the yields of Si{sup 2+} is comparable to that of Si{sup +}. Moreover, the ionization probability of Si atoms sputtered is shown to be expressed as an exponential function of the inverse of their velocity. The production mechanism for the doubly charged Si ion is discussed based on the L-shell ionization of Si atoms due to quasi-molecule formation in the collisions of the surface atoms with energetic recoils and subsequent Auger decay of the L-shell vacancy to doubly ionized Si ions.

  14. The bremsstrahlung induced by 0.3-2 keV electron scattering by Ar atoms

    International Nuclear Information System (INIS)

    Gnatchenko, E.V.; Tkachenko, A.A.; Verkhovtseva, E.T.

    2002-01-01

    The differential spectra of a bremsstrahlung resulting from a 0.3-2 keV electron scattering by Ar atoms are studied. Photon energies within the ultrasoft X-ray band from 124 to 190.8 eV, which is characterized by the low dynamic polarizability of the Ar atom, are considered. For the entire spectrum of photon energies (124-190.8 eV), the intensity of the bremsstrahlung differential spectra first grows with an increase in the electron energy from 0.3 to 0.7 keV and then decreases as the electron energy increases from 0.7 to 2 keV. The increase in intensity is directly proportional, and the decrease is inversely proportional to the square root of the energy of the scattered electrons. Within the context of a 'low-energy' approximation, the increase in the number of photons with the electron energy is due to the contribution of the atomic excitation and ionization channels being available during the bremsstrahlung process

  15. Consequences of a 17-keV neutrino

    International Nuclear Information System (INIS)

    Caldwell, D.O.; Langacker, P.

    1991-01-01

    If the controversial 17-keV neutrino exists, laboratory, astrophysical and cosmological bounds, unless significantly weakened, require that (1) it be a Majorana neutrino and mainly ν τ ; (2) it not be the dark matter of the universe, although its existence would rule out dominant hot dark matter; (3) the ν μ be a heavy Majorana neutrino of mass 17 keV or in the range 170--270 keV; and (4) the Mikheyev-Smirnov-Wolfenstein solution to the solar-neutrino problem involve ν e conversion to a light sterile [SU(2)-singlet] neutrino

  16. Dark Matter Limits From a 2L C3F8 Filled Bubble Chamber

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, Alan Edward [Univ. of Chicago, IL (United States)

    2015-12-01

    The PICO-2L C3F8 bubble chamber search forWeakly Interacting Massive Particle (WIMP) dark matter was operated in the SNOLAB underground laboratory at the same location as the previous CF3I lled COUPP-4kg detector. Neutron calibrations using photoneutron sources in C3F8 and CF3I lled calibration bubble chambers were performed to verify the sensitivity of these target uids to dark matter scattering. This data was combined with similar measurements using a low-energy neutron beam at the University of Montreal and in situ calibrations of the PICO-2L and COUPP-4kg detectors. C3F8 provides much greater sensitivity to WIMP-proton scattering than CF3I in bubble chamber detectors. PICO-2L searched for dark matter recoils with energy thresholds below 10 keV. Radiopurity assays of detector materials were performed and the expected neutron recoil background was evaluated to be 1.6+0:3

  17. Identification of an isomer in 110Ag at 1-keV excitation energy

    International Nuclear Information System (INIS)

    Clark, D.D.; Kostroun, V.O.; Siems, N.E.

    1975-01-01

    The existence of a new isomeric state in 110 Ag at approx. 1 keV excitation has been established in two experiments using a new instrument, the inner-shell-vacancy (ISV) detector. In the first experiment, a transition with a half-life of 660 plus-or-minus 40 ns was observed to follow the well-known 116-keV M4 transition that depopulates the 6 + 250-day isomeric level in 110 Ag; the energy of the new transition was deduced to be 109 Ag(n, γ) 110 Ag reaction to follow γ transitions previously assigned by others to populate a 1-keV excited state. The two results indicate the existence of a 2 - 660-ns isomer at 1.11 keV. Under the assumption that the newly observed transition is from a 2 - 1.11-keV state to the 1 + ground state, its hindrance factor with respect to the Moszkowski estimate is approx. 2.6 times 10 3 . Possible chemical-state perturbations of the measured half-life are estimated to be much smaller than the measurement error. In both experiments the approx. 1-keV transition was detected with the ISV detector, a new device based on the well-established atomic effect that within approx. 10 -14 s after the formation of an inner shell vacancy an atom will undergo a multiple loss of []lectrons ranging from several to 20 or more, the number being a function of Z and subshell. The emitted electrons, which are very soft, are collected with an accelerating and focusing electrostatic lens and detected with a plastic scintillator and a photomultiplier tube. Nuclear transitions that cause ISVs can thus be sensed. Experiments are described that show the detector is fast, sensitive, selective, and efficient in responding to ISVs.

  18. Elastic and inelastic processes in H+ + CH2 collisions below the 1.5 keV regime

    International Nuclear Information System (INIS)

    Suno, Hiroya; Rai, Sachchida N.; Liebermann, Heinz-Peter; Buenker, Robert J.; Kimura, Mineo; Janev, R.K.

    2005-01-01

    Electron capture and direct elastic scattering in collisions of H + ions with CH 2 molecules between 0.5 and 1.5 keV are theoretically investigated. A molecular representation is adopted within a fully quantum-mechanical approach. Differential cross sections (DCSs) for elastic scattering and electron capture are calculated at 1.5 keV and 0.5 keV for different molecular orientations. Our results indicate that electron capture dynamics and corresponding electron-capture cross sections depend substantially on the molecular orientation, thus revealing a strong steric effect. (author)

  19. Study of fission product {gamma} spectra in the band 2-500 keV; Etude du spectre {gamma} des produits de fission dans la bande 0-500 keV

    Energy Technology Data Exchange (ETDEWEB)

    Rousseau, A. [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    In the study of the {gamma} spectrum of uranium fission products, particular attention has been given in this note to the part of the spectrum ranging between 0 and 500 keV after a given pile operating programme and the evolution of this spectrum with time after a pile shutdown has been followed. The study be related to the fission products which appear in the pile as a whole or on those produced in a uranium sample assumed to have been placed in the pile. The latter case has been envisaged here. The spectrum determination is based partly on theory and partly on experiment. The pile operating conditions are different in the two cases, which widens the range of validity of the spectra traced here. (author) [French] Dans l'etude du spectre {gamma} des produits de fission de l'uranium, on s'est plus particulierement interesse dans la presente note a determiner la partie du spectre qui s'etend entre 0 et 500 keV, au bout d'un fonctionnement donne de pile, et a suivre l'evolution de ce spectre dans le temps apres un arret de pile. L'etude peut porter sur les produits de fission apparus dans toute la pile ou sur ceux apparus dans un echantillon d'uranium suppose place en pile. C'est ce dernier cas que nous avons envisage. La determination du spectre s'appuie sur une partie theorique et sur une partie experimentale. Les fonctionnements de pile choisis sont differents dans les deux cas, ce qui permet d'etendre la gamme de validite des spectres traces ici. (auteur)

  20. Study of fission product {gamma} spectra in the band 2-500 keV; Etude du spectre {gamma} des produits de fission dans la bande 0-500 keV

    Energy Technology Data Exchange (ETDEWEB)

    Rousseau, A [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    In the study of the {gamma} spectrum of uranium fission products, particular attention has been given in this note to the part of the spectrum ranging between 0 and 500 keV after a given pile operating programme and the evolution of this spectrum with time after a pile shutdown has been followed. The study be related to the fission products which appear in the pile as a whole or on those produced in a uranium sample assumed to have been placed in the pile. The latter case has been envisaged here. The spectrum determination is based partly on theory and partly on experiment. The pile operating conditions are different in the two cases, which widens the range of validity of the spectra traced here. (author) [French] Dans l'etude du spectre {gamma} des produits de fission de l'uranium, on s'est plus particulierement interesse dans la presente note a determiner la partie du spectre qui s'etend entre 0 et 500 keV, au bout d'un fonctionnement donne de pile, et a suivre l'evolution de ce spectre dans le temps apres un arret de pile. L'etude peut porter sur les produits de fission apparus dans toute la pile ou sur ceux apparus dans un echantillon d'uranium suppose place en pile. C'est ce dernier cas que nous avons envisage. La determination du spectre s'appuie sur une partie theorique et sur une partie experimentale. Les fonctionnements de pile choisis sont differents dans les deux cas, ce qui permet d'etendre la gamme de validite des spectres traces ici. (auteur)

  1. M sub shell X-ray emission cross section measurements for Pt, Au, Hg, Pb, Th and U at 8 and 10 keV synchrotron photons

    International Nuclear Information System (INIS)

    Kaur, Gurpreet; Gupta, Sheenu; Tiwari, M.K.; Mittal, Raj

    2014-01-01

    Highlights: • First time M sub shell fluorescence cross section measurements at 8 and 10 keV photons. • Comparison with theoretical evaluations from different model data for parameters. • Explained the large deviations from the trend of parameters with atomic number Z. • A specific pattern of cross sections with Z is predicted in the region, 78 ⩽ Z ⩽ 92. • Confirmation of prediction requires more experiment in these Z and energy region. -- Abstract: M sub shell X-ray emission cross sections of Pt, Au, Hg, Pb, Th and U at 8 and 10 keV photon energies have been determined with linearly polarized photon beam from Indus-2 synchrotron source. The measured cross sections have been reported for the first time and were used to check the available theoretical Dirac–Hartree–Slater (DHS) and Dirac–Fock (DF) values reported in literature and also the presently derived Non Relativistic Hartree–Slater (NRHS), DF and DHS values for M ξ , M δ , M α , M β , M γ , M m1 and M m2 group of X-rays

  2. Sputtering of solid nitrogen and oxygen by keV hydrogen ions

    DEFF Research Database (Denmark)

    Ellegaard, O.; Schou, Jørgen; Stenum, B.

    1994-01-01

    Electronic sputtering of solid nitrogen and oxygen by keV hydrogen ions has been studied at two low-temperature setups. The yield of the sputtered particles has been determined in the energy regime 4-10 keV for H+, H-2+ and H-3+ ions. The yield for oxygen is more than a factor of two larger than...... that for nitrogen. The energy distributions of the sputtered N2 and O2 molecules were measured for hydrogen ions in this energy regime as well. The yields from both solids turn out to depend on the sum of the stopping power of all atoms in the ion. The yield increases as a quadratic function of the stopping power...

  3. Are X-ray emitting coronae around supermassive black holes outflowing?

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Teng; Wang, Jun-Xian; Yang, Huan; Zhu, Fei-Fan; Zhou, You-Yuan, E-mail: liuteng@ustc.edu.cn, E-mail: jxw@ustc.edu.cn [CAS Key Laboratory for Research in Galaxies and Cosmology, Department of Astronomy, University of Science and Technology of China, Hefei, Anhui 230026 (China)

    2014-03-10

    Hard X-ray emission in radio-quiet active galactic nuclei (AGNs) is believed to be produced via inverse Compton scattering by hot and compact coronae near the supermassive black hole. However, the origin and physical properties of the coronae, including geometry, kinematics, and dynamics, remain poorly known. In this work, taking [O IV] 25.89 μm emission line as an isotropic indicator of AGNs' intrinsic luminosity, we compare the intrinsic corona X-ray emission between Seyfert 1 and Compton-thin Seyfert 2 galaxies, which are viewed at different inclinations according to the unification scheme. We compile a sample of 130 Compton-thin Seyfert galaxies with both [O IV] 25.89 μm line luminosities measured with the Spitzer Infrared Spectrometer and X-ray spectra observed by XMM-Newton, Chandra, Suzaku, or Swift. Known radio-loud sources are excluded. We fit the X-ray spectra to obtain the absorption-corrected 2-10 keV continuum luminosities. We find that Seyfert 1 galaxies are intrinsically brighter in intrinsic 2-10 keV emission by a factor of 2.8{sub −0.4}{sup +0.5} (2.2{sub −0.3}{sup +0.9} in Swift Burst Alert Telescope 14-195 keV emission), compared with Compton-thin Seyfert 2 galaxies. The Seyfert 1 and Compton-thin Seyfert 2 galaxies follow a statistically identical correlation between the absorption-corrected 2-10 keV luminosity and the 14-195 keV luminosity, indicating that our absorption correction to the 2-10 keV flux is sufficient. The difference in X-ray emission between the two populations is thus unlikely to be due to X-ray absorption, and instead implies an intrinsic anisotropy in the corona X-ray emission. This striking anisotropy of X-ray emission can be explained by a bipolar outflowing corona with a bulk velocity of ∼0.3-0.5c. This would provide a natural link between the so-called coronae and weak jets in these systems. Other consequences of outflowing coronae are also discussed.

  4. Test of a compact 750 keV H- preinjector

    International Nuclear Information System (INIS)

    Meitzler, C.R.; Datte, P.; Huson, F.R.; Kazimi, R.; Kronke, C.; Machida, S.; MacKay, W.; Ohnuma, S.; Raparia, D.; Sun, D.; Tompkins, P.; Ziegler, J.

    1989-01-01

    A 750 keV RFQ based accelerator is being developed at the Texas Accelerator Center. A modified magnetron ion source will produce 10--100 mA of 30 keV H - beam. A 35 keV transport line that transports the beam from the ion source to the entrance of the RFQ without becoming neutralized has been designed and is under construction. The RFQ is a 86 cm long, four rod structure that operates at 470 MHz. Results of tests on the cold model are reported. 5 refs

  5. Determination of Psub(K) values to the 172, 103 and 97 keV levels and the fluorescence yield. omega. sub(K) of Eu after electron capture by /sup 153/Gd

    Energy Technology Data Exchange (ETDEWEB)

    Singh, K; Grewal, B S; Sahota, H S [Punjabi Univ., Patiala (India). Dept. of Physics

    1985-03-01

    From an analysis of K x-ray-..gamma..-ray sum peaks observed with an intrinsic Ge detector the K-capture probabilities (Psub(K)) to the 172, 103 and 97 keV levels in the decay of /sup 153/Gd have been determined; these yield an electron-capture energy Qsub(EC)=245 +- 2. The K-capture probability to the 172 keV level differs significantly from that found in the literature. With these results the K-shell fluorescence yield of Eu is ..omega..sub(K)=0.935 +- 0.019.

  6. The Galactic 511 keV line: analysis and interpretation of Integral observations; L'annihilation des positrons galactiques: analyse et interpretation des donnees INTEGRAL

    Energy Technology Data Exchange (ETDEWEB)

    Lonjou, V

    2005-09-15

    Ever since the discovery of the 511 keV annihilation line emission from the galactic center region in the late seventies, the origin of galactic positrons has been the topic of a vivid scientific debate. It is also one of the prime scientific objectives of the imaging spectrometer SPI on board ESA's INTEGRAL observatory. In this thesis first a description of the most important SPI sub-system is given - the detector plane. Procedures for detector energy calibration and detector degradation analysis are developed. The determination of instrumental background models, a crucial aspect of data analysis, is elaborated. These background models are then applied to deriving sky maps and spectra of unprecedented quality of the Galactic positron annihilation radiation. The emission is centered on the galactic center with a spatial resolution of 8 degrees (FWHM), a second spatial component appears clearly: the galactic disc. The ray energy has been measured with unprecedented accuracy: 511.0 {+-} 0.03 keV for a full width at half maximum (FWHM) of 2.07 {+-} 0.1 keV. The total galactic flux ranges from 1.09 to 2.43 10{sup -3} ph.cm{sup -2}.s{sup -1} including uncertainties on spatial distribution. Finally, the implications of these observations for the production of positrons by various Galactic populations are discussed.

  7. A comparative study of inelastic scattering models at energy levels ranging from 0.5 keV to 10 keV

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Chia-Yu [Department of Photonics, National Cheng Kung University, Tainan 701, Taiwan (China); Lin, Chun-Hung, E-mail: chlin@mail.ncku.edu.tw [Department of Photonics, National Cheng Kung University, Tainan 701, Taiwan (China); Advanced Optoelectronic Technology Center, National Cheng Kung University, Tainan 701, Taiwan (China)

    2017-03-01

    Six models, including a single-scattering model, four hybrid models, and one dielectric function model, were evaluated using Monte Carlo simulations for aluminum and copper at incident beam energies ranging from 0.5 keV to 10 keV. The inelastic mean free path, mean energy loss per unit path length, and backscattering coefficients obtained by these models are compared and discussed to understand the merits of the various models. ANOVA (analysis of variance) statistical models were used to quantify the effects of inelastic cross section and energy loss models on the basis of the simulated results deviation from the experimental data for the inelastic mean free path, the mean energy loss per unit path length, and the backscattering coefficient, as well as their correlations. This work in this study is believed to be the first application of ANOVA models towards evaluating inelastic electron beam scattering models. This approach is an improvement over the traditional approach which involves only visual estimation of the difference between the experimental data and simulated results. The data suggests that the optimization of the effective electron number per atom, binding energy, and cut-off energy of an inelastic model for different materials at different beam energies is more important than the selection of inelastic models for Monte Carlo electron scattering simulation. During the simulations, parameters in the equations should be tuned according to different materials for different beam energies rather than merely employing default parameters for an arbitrary material. Energy loss models and cross-section formulas are not the main factors influencing energy loss. Comparison of the deviation of the simulated results from the experimental data shows a significant correlation (p < 0.05) between the backscattering coefficient and energy loss per unit path length. The inclusion of backscattering electrons generated by both primary and secondary electrons for

  8. Double capture in the O/sup 8+/ + He collision investigated by electron spectroscopy (80 keV, 10 deg)

    Energy Technology Data Exchange (ETDEWEB)

    Moretto-Capelle, P.; Benoit-Cattin, P.; Bordenave-Montesquieu, A.; Boudjema, M.; Gleizes, A.; Oza, D.H.; Dousson, S.; Hitz, D.

    1989-01-28

    Double capture into (3,n) autoionising states of O/sup 6+/ is observed in the O/sup 8+/ + He collision system by electron spectroscopy at 80 keV, 10/sup 0/. A comparison of the experimental results with theoretical positions and lifetimes allows the (3,3) states as well as three groups of (3,4) states to be identified. The present experimental findings are compared with earlier data for the N/sup 7+/ + He and Ne/sup 8+/(1s/sup 2/) + He systems. The influence of the core of the multicharged ion is studied by examining the O/sup 8+/ and Ne/sup 8+/(1s/sup 2/) results. The total double capture cross section is found to be large and it is compared with available experimental and theoretical data.

  9. Studies on the bombardment of condensed molecular gases at liquid-He temperatures by keV electrons and light ions

    International Nuclear Information System (INIS)

    Boergesen, P.

    1982-09-01

    Films of solid H 2 , D 2 and N 2 were irradiated with keV electrons and ions. Stopping cross sections and ranges of 0.3-10 keV/amu light ions in solid H 2 and D 2 are in good agreement with experimental and theoretical data on gaseous targets. In contrast, both stopping cross section and range measurements in solid N 2 suggest that the stopping here is only about half of that in N 2 -gas. This ''phase-effect'' is further supported by secondary emission measurements. Secondary electron emission coefficients for 2-10 keV H 1 + , H 2 + , H 3 + , D 3 + , D 2 H + , 4 He + , 14 N + and 20 Ne + incident on solids H 2 , D 2 and N 2 are in reasonable agreement with previous results for electron-incidence. The rather large erosion yields for 1-3 keV electrons incident on solid D 2 depend strongly on target thickness (for thin films), but weakly on energy. Bulk yields for 2 keV electrons were approximately 8 H 2 /electron, approximately 4 D 2 /electron and approximately 0.5 N 2 /electron. Secondary ion emission during ion bombardment seems to be predominantly reflected projectiles in the case of N 2 -targets, while it may be explained as sputtered particles from H 2 - and D 2 -targets. Preliminary results on the erosion of solid H 2 and D 2 by keV light ions indicate very large erosion yields (approx. 400 H 2 /atom for 2 keV protons) increasing strongly with energy. (Auth.)

  10. Preliminary investigations on the preparation of gold nanoparticles intrinsically radiolabeled with 199Au

    International Nuclear Information System (INIS)

    Vimalnath, K.V.; Chakraborty, Sudipta; Dash, Ashutosh

    2016-01-01

    Radiolabeled nanoparticles are of great interest in the current perspective of the nuclear medicine. Water dispersible materials with nanoscale dimensions are finding role in biomedical application owing to their size. These particles can access otherwise unreachable regions in tumor mainly due to Enhanced Permeability and Retention (EPR) effect. Nanoparticles of gold (AuNPs) can bind to a wide range of biologically active molecules with functional groups that have high affinity for the gold surface. Sulfur containing compounds (e.g. thiols, disulfides), organic phosphates, amines, PEG, etc. are some of the well known surface modifiers. Functional thiolates, oligonucleotides, peptides and PEGs are introduced upon subsequent bimolecular substitution of a ligand by a functional thiol easily attached to AuNPs. Owing to its favourable decay characteristics 199 Au (T 1/2 = 3.15 d, E âmax = 474 keV, Eg 158.4 keV (36.9 %) and 208.2 keV (8.4 %)) is an attractive radionuclide for theragnostic applications. In the present work, we have carried out preliminary radiochemical investigations on the preparation of gold nanoparticles intrinsically radiolabeled with 199 Au for its potential utility as a theragnostic agent targeted delivery to the tumors

  11. Kirkpatrick-Baez microscope with spherical multilayer mirrors around 2.5keV photon energy

    Science.gov (United States)

    An, Ning; Du, Xuewei; Wang, Qiuping; Cao, Zhurong; Jiang, Shaoen; Ding, Yongkun

    2014-09-01

    A Kirkpatrick-Baez (KB) x-ray microscope has been developed for the diagnostics of inertial confinement fusion (ICF). The KB microscope system works around 2.5keV with the magnification of 20. It consists of two spherical multilayer mirrors. The grazing angle is 3.575° at 2.5keV. The influence of the slope error of optical components and the alignment errors is simulated by SHADOW software. The mechanical structure which can perform fine tuning is designed. Experiment result with Manson x-ray source shows that the spatial resolution of the system is about 3-4μm over a field of view of 200μm.

  12. Azimuthal and polar angle dependence of L X-ray differential cross-sections of Yb at 59.54 keV photon energy

    Energy Technology Data Exchange (ETDEWEB)

    Akkuş, T.; Şahin, Y.; Yılmaz, D., E-mail: ddemir@atauni.edu.tr

    2016-01-01

    Highlights: • The azimuthal and polar angle dependence of L X-ray for Yb is investigated. • The azimuthal angle dependence of Ll and Lα X-rays are observed. • The azimuthal anisotropy of Lβ and Lγ X-rays are not observed. • The polar anisotropy of Ll and Lα X-rays are observed. • The polar anisotropy of Lβ and Lγ X-rays are not observed. - Abstract: The azimuthal and polar angle dependence of L X-ray was investigated in the same experimental setup to remove the existing ambiguity about alignments measurements. We measured Ll, Lα, Lβ and Lγ X-ray differential cross sections of Yb for several different azimuthal angles (30°, 20°, 10°, 0°, −10° and −20°) and polar angles (90°, 100°, 110°, 120°, 130° and 140°) at 59.54 keV photon energy by using a Si(Li) detector. The azimuthal angle dependence of Ll and Lα X-rays were observed. The azimuthal anisotropy of Lβ and Lγ X-rays were not observed. On the other hand, differential cross-sections for Lβ and Lγ X-rays were found independent on the polar angle within experimental error, those for Ll and Lα X-rays depended on the polar angles. Azimuthal and polar angles dependence of L X-ray differential cross-sections contrast with the other experimental and theoretical results, which report evidence of the isotropic emission of Ll and Lα X-rays following photoionization.

  13. The Preparation of an Electron Beam Machine 500 keV/10 mA Instrumentation

    International Nuclear Information System (INIS)

    Sudiyanto; Prayitno; Dewita; Bambang-Supardiyono; Widi-Setyawan

    2000-01-01

    The preparation of an Electron Beam Machine 500 keV/10 mA instrumentation by using a Distributed Instrumentation System have been done. The system consisting of industrial interfaces PCL-718 ADC 12 bit, PCLD-889 Mux/Prog Gain Amp PCLD-786 Driver Relay with solid state relays, PCL 745 serial com, DC motor 12-24 V/8.6 A with reduction gear 10:1 and a pair of PC's connected with twisted cable and an isolated amplifier AD-210 equipped with high voltage divider. The operation can be done using animation Pascal program on the remote mode using twisted cable and a pair of RS-485 interfaces, some operation sequences such as switch on/off blower unit, water pump cooling unit, filament voltage, anode voltage and some timer's have already been adapted on the computer program. Non intercepting beam monitoring technique have been discussed in this paper. (author)

  14. 2 keV filters of quasi-mono-energetic neutrons

    International Nuclear Information System (INIS)

    Adib, M.; Habib, N.; El-Mesiry, M.S.; Bashter, I.I.; Saleh, A.; Fathallah, M.

    2013-01-01

    A simulation study for the production of 2 keV filters of quasi-mono-energetic neutrons based on the deep interference minima in the 45 Sc total cross-section was carried out. A computer code QMENF-II was adapted to calculate the optimum amounts of the 45 Sc as a main filter element and additional component ones to obtain sufficient intensity at high resolution and purity of the filtered quasi-mono-energetic neutrons. The emitted neutron spectrum from nuclear reactor and from the reaction of 2.6 MeV protons on a lithium fluoride target at the accelerator beam port, are used for simulation

  15. The emission of characteristic and non-characteristic x-rays from collisions of 10-22 keV electrons with argon

    Energy Technology Data Exchange (ETDEWEB)

    Singh, R K; Shanker, R [Atomic Physics Laboratory, Department of Physics, Banaras Hindu University, Varanasi-221 005 (India)

    2003-07-28

    Measurements of the emission cross sections of the characteristic and the non-characteristic x-rays produced from collisions of 10-22 keV electrons with Ar atoms are presented. The relative cross sections for Ar K-shell ionization as a function of impact energy are shown to yield satisfactory agreement (within the experimental uncertainty) with Born-Ochkur calculations and with results obtained from an empirical formula proposed by Hombourger (1998 J. Phys. B: At. Mol. Opt. Phys. 31 3693). Furthermore, the double differential cross sections of bremsstrahlung photons emitted from 10-22 keV e{sup -}-Ar collisions as a function of impact energy for different photon energies were measured. The shape of the experimental bremsstrahlung cross section function is found to exhibit good agreement with the theoretical calculations of Kissel et al (1983 At. Data Nucl. Data Tables 28 381) within the experimental uncertainty. In addition, the shape of the angular distributions of the bremsstrahlung is in accord with the calculations of Kissel et al and those of the modified Sommerfeld (Kulenkampff et al 1959 Z. Phys. 157 275) formula.

  16. Calculation of W for low energy electrons in tissue-equivalent gas. [<10 keV

    Energy Technology Data Exchange (ETDEWEB)

    Dayashankar, [Bhabha Atomic Research Centre, Bombay (India). Div. of Radiation Protection

    1977-11-01

    The mean energy expended per ion pair formed (W-value) in the tissue-equivalent gas for incident electrons of energy up to 10 keV has been calculated in the continuous slowing-down approximation. The effect of secondary and tertiary electrons has been considered by utilizing recent measurements of Opal et al., (1971, J. Chem. Phys., 55,4100) on the energy spectra of low-energy secondary electrons and the Mott formula for the spectra of high-energy secondaries. The results, which are provisional in nature due to the limitations on the accuracy of the input cross-section data and the neglect of the discrete nature of energy loss process, are compared with the available measurements.

  17. Measurement of L x-ray emission from elements in 64 ≤ Z ≤ 73 interval stimulated by 59.54 keV photons

    International Nuclear Information System (INIS)

    Baraldi, C; Casnati, E; Tartari, A; Singh, B

    2005-01-01

    Accurate measurements (mostly within 5%) of L α , L β and L γ x-ray emission cross sections were carried out on thick foils of elements lying in 64 ≤ Z ≤ 73 interval, stimulated by 59.54 keV photons. They can be of help as an overall reference to compare the theoretical and semi-empirical approaches by which the atomic parameters included in the expressions of L emission cross sections are evaluated. An appropriate extension of the expression linking the cross section to the counting rate measured in reflection geometry on thick targets makes it possible to overcome the difficulties arising from the width in energy of the L β and L γ groups and from the jump present in the attenuation coefficients of the target elements within the energy interval of their L γ emission lines

  18. 1- to 10-keV x-ray backlighting of annular wire arrays on the Sandia Z-machine using bent-crystal imaging techniques

    International Nuclear Information System (INIS)

    Rambo, Patrick K.; Wenger, David Franklin; Bennett, Guy R.; Sinars, Daniel Brian; Smith, Ian Craig; Porter, John Larry Jr.; Cuneo, Michael Edward; Rovang, Dean Curtis; Anderson, Jessica E.

    2003-01-01

    Annular wire array implosions on the Sandia Z-machine can produce >200 TW and 1-2 MJ of soft x rays in the 0.1-10 keV range. The x-ray flux and debris in this environment present significant challenges for radiographic diagnostics. X-ray backlighting diagnostics at 1865 and 6181 eV using spherically-bent crystals have been fielded on the Z-machine, each with a ∼0.6 eVspectral bandpass, 10 (micro)m spatial resolution, and a 4 mm by 20mm field of view. The Z-Beamlet laser, a 2-TW, 2-kJ Nd:glass laser(λ = 527 nm), is used to produce 0.1-1 J x-ray sources for radiography. The design, calibration, and performance of these diagnostics is presented.

  19. L1 and L2 sub-shell fluorescence yields for elements with 64 ≤ Z ≤ 70

    International Nuclear Information System (INIS)

    Kumar, Anil; Puri, Sanjiv

    2010-01-01

    The L 1 and L 2 sub-shell fluorescence yields have been deduced for elements with 64 ≤ Z ≤ 70 from the L k (k = l, α, β 1,4 , β 3,6 , β 2,15,9,10,7 , γ 1,5 and γ 2,3,4 ) X-ray production cross sections measured at 22.6 keV incident photon energy using a spectrometer involving a disc type radioisotope of Cd 109 as a photon source and a Peltier cooled X-ray detector. The incident photon intensity, detector efficiency and geometrical factor have been determined from the K X-ray yields emitted from elemental targets with 20 ≤ Z ≤ 42 in the same geometrical setup and from knowledge of the K shell cross sections. The present deduced ω 1 (exp) values, for elements with 64 ≤ Z ≤ 70, are found to be in good agreement with those tabulated by Campbell (J.L. Campbell, Atom. Data Nucl. Data Tables 95 (2009) 115), where as these are, on an average, higher by 19% and 24% than those based on the Dirac-Hartree-Slater model (S. Puri et al., X-ray Spectrometry 22 (1993) 358) and the semi-empirical values compiled by Krause (M.O. Krause, J. Phys. Chem. Ref. Data 8 (1979) 307), respectively. The present deduced ω 2 (exp) values are found to be in good agreement with those based on the Dirac-Hartree-Slater model and are higher by up to ∼13% than the semi-empirical values for the elements under investigation.

  20. L 1 and L 2 sub-shell fluorescence yields for elements with 64 ⩽ Z ⩽ 70

    Science.gov (United States)

    Kumar, Anil; Puri, Sanjiv

    2010-05-01

    The L 1 and L 2 sub-shell fluorescence yields have been deduced for elements with 64 ⩽ Z ⩽ 70 from the L k( k = l, α, β1,4, β3,6, β2,15,9,10,7, γ1,5 and γ2,3,4) X-ray production cross sections measured at 22.6 keV incident photon energy using a spectrometer involving a disc type radioisotope of Cd 109 as a photon source and a Peltier cooled X-ray detector. The incident photon intensity, detector efficiency and geometrical factor have been determined from the K X-ray yields emitted from elemental targets with 20 ⩽ Z ⩽ 42 in the same geometrical setup and from knowledge of the K shell cross sections. The present deduced ω1(exp) values, for elements with 64 ⩽ Z ⩽ 70, are found to be in good agreement with those tabulated by Campbell (J.L. Campbell, Atom. Data Nucl. Data Tables 95 (2009) 115), where as these are, on an average, higher by 19% and 24% than those based on the Dirac-Hartree-Slater model (S. Puri et al., X-ray Spectrometry 22 (1993) 358) and the semi-empirical values compiled by Krause (M.O. Krause, J. Phys. Chem. Ref. Data 8 (1979) 307), respectively. The present deduced ω2(exp) values are found to be in good agreement with those based on the Dirac-Hartree-Slater model and are higher by up to ˜13% than the semi-empirical values for the elements under investigation.

  1. Energy Reflection Coefficients for 5-10 keV He Ions Incident on Au, Ag, and Cu

    DEFF Research Database (Denmark)

    Schou, Jørgen; Sørensen, H.; Littmark, U.

    1978-01-01

    The calorimetric deuterium-film method was used for measurements of the energy reflection coefficient γ for normal incidence of 5-10 keV He ions on Cu, Ag and Au. A theoretical calculation of γ by means of transport theory gives fair agreement with the experimental results. The experimental data...... the experimental and theoretical results for the He ions are in acceptable agreement with other experimental and theoretical results. For He ions, the experimental γ-values are 20-30% above the values for hydrogen ions for the same value of ε...

  2. Developing Intentionality and L2 Classroom Task-Engagement

    Science.gov (United States)

    Stelma, Juup

    2014-01-01

    This paper extends work on "intentionality", from philosophy, psychology and education to an exploration of learners' meaning-making in L2 classroom task-engagement. The paper draws on both phenomenological and folk-psychological perspectives on intentionality, and employs John R. Searle's intrinsic (mental) and derived (observable)…

  3. Design and environmental applications of an ultra-low-background, high-efficiency intrinsic Ge gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Wogman, N.A.

    1981-04-01

    A coincidence shielded intrinsic Ge gamma-ray spectrometer incorporating a 25% efficient, high resolution coaxial diode inside a 30 cm diameter NaI(Tl) shield is described. System design eliminates the major cause of background and minimizes cosmic-ray created background events through the use of electronic means. The system provides a peak-to-Compton ratio of greater than 1000 to 1 for 137 Cs and high sensitivity for both low and high level radionuclide measurements. At 3 MeV the background is 0.000058 counts per minute per keV. At 1 MeV it is 0.00048 counts per minute per keV, and at 0.5 MeV it is 0.0045 counts per minute per keV. Traces of primordial radionuclides create background events such as at 2.614 MeV (0.016 counts per minute total peak area), at 2.448 MeV (0.0058 counts per minute per total peak area), and at 2.204 MeV (0.023 counts per minute per total peak area). The system is discussed with respect to its background design, methods to improve its design, and its application to measurements of neutron activated and environmental materials problems

  4. Search for a resonance in the 14N(p,γ)15O reaction at Ep=127 keV

    International Nuclear Information System (INIS)

    Runkle, R.C.; Champagne, A.E.; Fox, C.; Iliadis, C.; Pollanen, J.; Stephan, A.; Westerfeldt, C.

    2002-01-01

    The 14 N(p,γ) 15 O reaction regulates the energy produced by the CN cycle in main-sequence stars and in red giants. Recently, preliminary evidence was presented for a new resonance in this reaction, which would significantly increase the reaction rate for temperatures near 10 8 K. We have attempted to confirm this result and find no indication of a resonance near E p lab =127 keV. Our upper limit on its strength is ωγ≤32 neV (95% C.L.), which is more than 2 orders of magnitude below the previously reported value

  5. Experimental results on 2-30 keV bremsstrahlung from thick and thin targets

    Energy Technology Data Exchange (ETDEWEB)

    Shanker, R. [Atomic Physics Laboratory, Physics Department, Banaras Hindu University, Varanasi 221005 (India)]. E-mail: rshanker@bhu.ac.in

    2006-10-15

    The recent experimental investigations on electron bremsstrahlung produced from impact of 2-30 keV electrons with thick solid and thin gaseous targets are reviewed. The theoretical models describing the energy and angular distributions of bremsstrahlung photons are discussed with their brief outlines and formulations to explain the experimental data. The results on thick target bremsstrahlung (TTB) spectra produced by keV electrons have suggested that there is a need to develop a comprehensive theory for accounting the solid state effects. It is further noted that the prediction of the modified KKD formula gives a reasonable agreement with the TTB data, whereas a semi-empirical formula gives a better fit to the data for thick targets. The available experimental data for dependence of double differential cross-sections of emitted photons on impact energy and their emission angles for gaseous atoms and molecules exhibit a good agreement with the theoretical calculations of Kissel et al., [1983. Shape functions for atomic-field bremsstrahlung from electrons of kinetic energy 1-500 keV on selected neutral atoms 1

  6. Interferometric phase-contrast X-ray CT imaging of VX2 rabbit cancer at 35keV X-ray energy

    Science.gov (United States)

    Takeda, Tohoru; Wu, Jin; Tsuchiya, Yoshinori; Yoneyama, Akio; Lwin, Thet-Thet; Hyodo, Kazuyuki; Itai, Yuji

    2004-05-01

    Imaging of large objects at 17.7-keV low x-ray energy causes huge x-ray exposure to the objects even using interferometric phase-contrast x-ray CT (PCCT). Thus, we tried to obtain PCCT images at high x-ray energy of 35keV and examined the image quality using a formalin-fixed VX2 rabbit cancer specimen with 15-mm in diameter. The PCCT system consisted of an asymmetrically cut silicon (220) crystal, a monolithic x-ray interferometer, a phase-shifter, an object cell and an x-ray CCD camera. The PCCT at 35 keV clearly visualized various inner structures of VX2 rabbit cancer such as necrosis, cancer, the surrounding tumor vessels, and normal liver tissue. Besides, image-contrast was not degraded significantly. These results suggest that the PCCT at 35 KeV is sufficient to clearly depict the histopathological morphology of VX2 rabbit cancer specimen.

  7. Absolute cross sections for the multielectron processes in 15 keV I10++rare gas collisions

    International Nuclear Information System (INIS)

    Nakamura, N.; Currell, F.J.; Danjo, A.; Kimura, M.; Matsumoto, A.; Ohtani, S.; Sakaue, H.A.; Sakurai, M.; Tawara, H.; Watanabe, H.; Yamada, I.; Yoshino, M.

    1995-01-01

    We have experimentally determined the absolute cross sections for total charge transfer (σ q ), j electron transfer (σ j q ), i electron capture (σ q,q-i ) and each reaction process (σ j q,q-i ) in 15 keV I 10+ -Ne, Ar, Kr and Xe collisions. The branching ratios were determined by the coincidence measurements between charge changing projectile and recoil ions. The electron capture cross sections were measured by the initial growth rate method. The experimental results for total and j electron transfer cross sections were compared with the predictions of the extended classical over-barrier model (ECBM). (orig.)

  8. Absolute total and one- and two-electron transfer cross sections for Arq+ (8≤q≤16) on He and H2 at 2.3q keV

    International Nuclear Information System (INIS)

    Vancura, J.; Marchetti, V.J.; Perotti, J.J.; Kostroun, V.O.

    1993-01-01

    Absolute values for the total and one- and two-electron transfer cross sections for Ar q+ ions (8≤q≤16) colliding with helium and molecular hydrogen at 2.3q keV laboratory energy were measured by the growth-rate method. The He and H 2 total cross sections as a function of Ar-projectile L-shell occupation number increase monotonically from Ar 8+ , 2p shell full, to Ar 16+ , 2s shell empty. The H 2 one-electron capture cross section scales approximately as [E IP (He)/E IP (H 2 )] 2 times the corresponding He cross section, but the shapes of the two cross sections differ in detail. The Ar q+ ions were produced by the Cornell superconducting-solenoid, cryogenic electron-beam ion source (CEBIS) and extracted at 2.3 kV. Selected charge states traversed a gas cell, after which they were detected and charge-state analyzed by the energy-retardation method and by a π/ √2 cylindrical electrostatic analyzer. The target-gas pressure in the cell was measured directly by the orifice-flow method used for absolute-pressure gauge calibration. The overall error in the Ar q+ on H 2 cross-section measurements is ±10%, and ±15% in the He measurements

  9. X-ray fluorescence cross sections for K and L x rays of the elements

    International Nuclear Information System (INIS)

    Krause, M.O.; Nestor, C.W. Jr.; Sparks, C.J. Jr.; Ricci, E.

    1978-06-01

    X-ray fluorescence cross sections are calculated for the major x rays of the K series 5 less than or equal to Z less than or equal to 101, and the three L series 12 less than or equal to Z less than or equal to 101 in the energy range 1 to 200 keV. This calculation uses Scofield's theoretical partical photoionization cross sections, Krause's evaluation of fluorescence and Coster-Kronig yields, and Scofield's theoretical radiative rates. Values are presented in table and graph format, and an estimate of their accuracy is made. The following x rays are considered: Kα 1 , Kα 1 , 2 , Kβ 1 , Kβ 1 , 3 , Lα 1 , Lα 1 , 2 , Lβ 1 , Lβ 2 , 15 , Lβ 3 , Ll, Lγ 1 , Lγ 4 , and L 1 → L 2 , 3 . For use in x-ray fluorescence analysis, Kα and Lα fluorescence cross sections are presented at specific energies: TiK identical with 4.55 keV, CrK identical with 5.46 keV, CoK identical with 7.00 keV, CuK identical with 8.13 keV, MoKα identical with 17.44 keV, AgK identical with 22.5 keV, DyK identical with 47.0 keV, and 241 Am identical with 59.54 keV. Supplementary material includes fluorescence and Coster--Kronig yields, fractional radiative rates, fractional fluorescence yields, total L-shell fluorescence cross sections, fluorescence and Coster-Kronig yields in condensed matter, effective fluorescence yields, average L-shell fluorescence yield, L-subshell photoionization cross section ratios, and conversion factors from barns per atom to square centimeters per gram

  10. Measurement of the fission cross section of uranium-235 between 4 eV and 20 keV; Mesure de la section efficace de fission de l'uranium-235 entre 4 eV et 20 keV

    Energy Technology Data Exchange (ETDEWEB)

    Michaudon, A; Genin, R; Joly, R; Vendryes, G

    1959-01-01

    The neutron fission cross section of uranium-235 has been measured between 4 ev and 20 kev by the time of flight method with the Saclay electron linear accelerator as a pulsed neutron source. After a brief description of the experimental apparatus and the conditions of work during the experiment, the curve {sigma}{sub F} {radical}E in the energy range studied is shown. This curve is then analyzed by the ''area'' method and a set of {sigma}{sub 0} {gamma}{sub F} values is obtained. With {sigma}{sub 0} {gamma} values measured in other laboratories, it is possible to compute fission widths for several resonances and to study their distribution. This distribution is then compared to Porter-Thomas distributions with different values of the number of exit channels. (authors) [French] La section efficace de fission de l'uranium--235 a ete mesuree entre 4 eV et 20 KeV par la methode du temps de vol en utilisant l'accelerateur lineaire a electrons de Saclay comme source pulses de neutrons. Apres une rapide description de l'appareillage experimental et des conditions de fonctionnement au cours de l'experience, on presente la courbe {sigma}{sub F} {radical}E obtenue dans la game d'energie etudiee. Cette courbe est ensuite analysee par la methode de surface des resonances et un lot de valeurs de {sigma}{sub 0} {gamma}{sub F} est obtenue. Conjuguee avec les valeurs de {sigma}{sub 0} {gamma} obtenues dans d'autres laboratoires, cette analyse permet de calculer les largeurs de fission pour plusieurs resonances et d'etudier leur distribution. Cette distribution est ensuite comparee aux distributions de Porter et Thomas correspondant a differentes valeurs du nombre de voies de sortie. (auteurs)

  11. Incentives and intrinsic motivation in healthcare.

    Science.gov (United States)

    Berdud, Mikel; Cabasés, Juan M; Nieto, Jorge

    It has been established in the literature that workers within public organisations are intrinsically motivated. This paper is an empirical study of the healthcare sector using methods of qualitative analysis research, which aims to answer the following hypotheses: 1) doctors are intrinsically motivated; 2) economic incentives and control policies may undermine doctors' intrinsic motivation; and 3) well-designed incentives may encourage doctors' intrinsic motivation. We conducted semi-structured interviews à-la-Bewley with 16 doctors from Navarre's Healthcare Service (Servicio Navarro de Salud-Osasunbidea), Spain. The questions were based on current theories of intrinsic motivation and incentives to test the hypotheses. Interviewees were allowed to respond openly without time constraints. Relevant information was selected, quantified and analysed by using the qualitative concepts of saturation and codification. The results seem to confirm the hypotheses. Evidence supporting hypotheses 1 and 2 was gathered from all interviewees, as well as indications of the validity of hypothesis 3 based on interviewees' proposals of incentives. The conclusions could act as a guide to support the optimal design of incentive policies and schemes within health organisations when healthcare professionals are intrinsically motivated. Copyright © 2016 SESPAS. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. Pu241 cross-sections below 1 keV

    International Nuclear Information System (INIS)

    Doherty, G.

    1966-12-01

    Early in 1965 a new data file (DFN 40) for Pu241 covering the energy range 10 - 4 eV to 15 MeV was prepared for the UKAEA Nuclear Data Library. The data above 1 keV are described by Douglas (AWRE 0-101/64) and the data below 1 keV are set out in this report. During the past year a number of additional measurements have been reported for Pu241 and a brief summary of these measurements and their implications for the data on the file are given. (author)

  13. Fluence to Effective Dose and Effective Dose Equivalent Conversion Coefficients for Photons from 50 KeV to 10 GeV

    International Nuclear Information System (INIS)

    Ferrari, A.; Pelliccioni, M.; Pillon, M.

    1996-07-01

    Effective dose equivalent and effective dose per unit photon fluence have been calculated by the FLUKA code for various geometrical conditions of irradiation of an anthropomorphic phantom placed in a vacuum. Calculations have been performed for monoenergetic photons of energy ranging from 50 keV to 10 GeV. The agreement with the results of other authors, when existing, is generally very satisfactory

  14. Energy dependence of the air kerma response of a liquid ionization chamber at photon energies between 8 keV and 1250 keV

    International Nuclear Information System (INIS)

    Hilgers, G.; Bahar-Gogani, J.; Wickman, G.

    2002-01-01

    Full text: In its recent reports on cardiovascular brachytherapy the DGMP recommends the source strength of brachytherapy sources being characterized in terms of absorbed dose to water at a distance of 2 mm from the central axis of the source. As a consequence, the response of a detector suitable for characterizing such sources with respect to absorbed dose to water should depend only to a small extent on radiation energy. Additionally, the detection volume of the detector has to be sufficiently small for the necessary spatial resolution to be obtained. The liquid ionization chamber as described in seems to be a promising means for this type of measurements. The two components of the ionization liquid (TMS and isooctane) can be mixed in a ratio which ensures that the mass-energy absorption coefficient of the resulting mixture deviates from that of water by less than ±15 % down to photon energies of 10 keV. Due to the high density of the ionization medium, the spacing between the two electrodes of the ionization chamber can be made as small as a few tenths of a millimeter and still the resulting ionization current is sufficiently large. The ionization chamber used in the present investigation is a plane parallel chamber 5 mm in diameter and of 0.3 mm electrode spacing. The ionization medium is a mixture of 40 % TMS and 60 % isooctane. The irradiations were carried out with the ISO wide spectra series with tube voltages between 10 kV and 300 kV and with 137 Cs and 60 Co γ-radiation. As a first step, the response of the liquid ionization chamber was investigated with respect to air kerma instead of absorbed dose to water. Although the mass-energy absorption coefficient of the liquid deviates from that of air by less than ±10 % over the photon energy range, the measured chamber response varies by a factor of about 3.5. Monte Carlo calculations carried out with EGSnrc show a variation of the chamber response smaller than ±20 %. Measurements of the ion yield of the

  15. Measurement of the 232Th capture cross section in the energy region 5 keV-150 keV

    International Nuclear Information System (INIS)

    Lobo, G.; Schillebeeckx, P.; Brusegan, A.; Borella, A.; Corvi, F.; Janeva, N.; Volev, K.

    2003-01-01

    The 232 Th(n,γ) neutron capture cross-section is of great importance for accelerator driven reactor (ADS) systems based on the Thorium-Uranium fuel cycle. An analysis of the required nuclear data, reveals that the status of the 232 Th capture data is far from the requested 2 % uncertainty level. Recently 232 Th average capture measurements, between 5-200 keV neutron energy, were performed at the FzK Karlsruhe (DE). A comparison of the measured averaged capture cross section with the evaluated data files shows a reasonable agreement in the neutron energy range above 15 keV. However, discrepancies of up to 40 % at lower neutron energies are observed. The same order of discrepancies is observed when comparing their results with the results obtained by Macklin et al. at ORELA. To clarify these discrepancies we measured at IRMM the average capture cross-section at the GEel LINear Accelerator (GELINA). The measurements were performed at a 14.37 m flight-path using the Time-Of-Flight (TOF) method. The gamma rays, originating from the 232 Th(n,γ) reaction, were detected by a pair of C 6 D 6 -based liquid scintillators applying a pulse-height weighting method. The neutron flux was measured with an ionisation chamber placed at 80 cm before the Thorium sample. This chamber has a cathode loaded with two back-to-back layers of about 40 μg/cm 2 10 B. The sample consisted of a metallic natural thorium disc of 8 cm diameter and 0.5 mm thick, corresponding to a thickness of 1.588 10 -3 at/b. The background for the capture measurements consists of a time independent and time dependent component. The former, mainly produced by the radioactive decay of the sample, was deduced from measurements with a closed beam. The latter was measured by replacing the thorium sample with a 0.5 mm thick 208 Pb sample of the same size. Such a Pb sample has practically the same scattering probability as the thorium sample and has a negligible capture yield. Therefore, the 208 Pb run provides a good

  16. MD study of primary damage in L10 TiAl structural intermetallics

    International Nuclear Information System (INIS)

    Voskoboinikov, Roman E.

    2013-01-01

    Computer modelling by molecular dynamics has been applied to study the radiation damage created in collision cascades in L1 0 TiAl intermetallic compound. Either Al or Ti primary knock-on atoms (PKA) with energy 5 keV ⩽ E PKA ⩽ 20 keV were introduced in the intermetallic crystals at temperatures ranging from 100 K to 900 K. At least 24 different cascade for each (E PKA , T, PKA type) set were modelled in order to simulate a random spatial and temporal distribution of PKAs and provide statistical reliability of the results. The total yield of more than 760 simulated cascades is the largest yet reported for this binary intermetallic material. A comprehensive treatment of the modelling results has been carried out. The number of Frenkel pairs, fraction of Al and Ti vacancies, self-interstitial atoms and anti-sites as a function of (E PKA , T, PKA type) has been established. Preferred formation of Al self-interstitial atoms has been detected in L1 0 TiAl structural intermetallics exposed to irradiation

  17. Excitation of the helium autoionizing states in He++He collisions, between 3 and 140 keV

    International Nuclear Information System (INIS)

    Bordenave-Montesquieu, A.; Gleizes, A.; Benoit-Cattin, P.

    1982-01-01

    The autoionization of the helium atom has been experimentally studied in He + +He collisions between 3 and 140 keV by electron spectrometry. The excitation of the two collision partners has been considered. Above 10 keV, the shapes and excitation cross sections of the 2s 2 1 S, 2s2p 3 P, 2p 2 1 D, and 2s2p 1 P are determined by a numerical fitting procedure which is reported in detail; below 10 keV the ( 1 D+ 1 P), and 2p 2 1 S line intensities are obtained by planimetry since important post-collision effects are observed. From the angular distributions measured below 15 keV, the relative sublevel populations are deduced for the 2p 2 1 D and 2s2p 1 P levels and are compared with those obtained by other authors in a coincidence experiment; the excitation processes are then discussed within the quasimolecular-excitation model. For the highest collision energies, the asymmetry of the angular distributions with respect to 90 0 as well as the line shapes above 100 keV are interpreted by the occurrence of sudden electronic transitions to the continuum. A comparison of the differential cross sections for emission of electrons by autoionization of the fast and slow particles permits us to show that the quasimolecule model cannot explain what is observed above a collision velocity of about 0.5 a.u. The dependence of the total cross sections against the collision energy is also discussed in terms of an evolution of the excitation mechanism from a quasimolecular to an atomic one; the specific variation of the 2s2p 3 P cross section strengthens this interpretation. These total cross sections are compared with those estimated from earlier H + +He data published by us; similar autoionization cross-section values are expected for the two systems at high collision velocity

  18. TC10 is regulated by caveolin in 3T3-L1 adipocytes.

    Directory of Open Access Journals (Sweden)

    Dave Bridges

    Full Text Available TC10 is a small GTPase found in lipid raft microdomains of adipocytes. The protein undergoes activation in response to insulin, and plays a key role in the regulation of glucose uptake by the hormone.TC10 requires high concentrations of magnesium in order to stabilize guanine nucleotide binding. Kinetic analysis of this process revealed that magnesium acutely decreased the nucleotide release and exchange rates of TC10, suggesting that the G protein may behave as a rapidly exchanging, and therefore active protein in vivo. However, in adipocytes, the activity of TC10 is not constitutive, indicating that mechanisms must exist to maintain the G protein in a low activity state in untreated cells. Thus, we searched for proteins that might bind to and stabilize TC10 in the inactive state. We found that Caveolin interacts with TC10 only when GDP-bound and stabilizes GDP binding. Moreover, knockdown of Caveolin 1 in 3T3-L1 adipocytes increased the basal activity state of TC10.Together these data suggest that TC10 is intrinsically active in vivo, but is maintained in the inactive state by binding to Caveolin 1 in 3T3-L1 adipocytes under basal conditions, permitting its activation by insulin.

  19. The repetitive flaking of Inconel 625 by 100 keV helium bombardment

    International Nuclear Information System (INIS)

    Whitton, J.L.; Chen, H.M.; Littmark, U.

    1981-01-01

    Repetitive flaking of Inconel 625 occurs with ion bombardment doses of > than 10 18 100 keV helium ions cm -2 , with up to 39 exfoliations being observed after bombardment with 3 x 10 19 ions cm -2 . The thickness of the flakes, measured by scanning electron microscopy, is some 30% greater than when measured by Rutherford backscattering (RBS) of 1.8 MeV helium ions. These RBS measurements compare well with the thickness of the remaining layers in the resultant craters and to the most probable range of the 100 keV helium. The area of the flakes is dictated by the grain boundaries, and when one flake is ejected, the adjacent grains are prevented from doing so since there now exists an escape route for the injected helium. A strong dose rate dependence is observed; decreasing the beam current from 640 μA cm -2 to 64 μA cm -2 results in a factor 20 fewer flakes being exfoliated (for the same total dose of 3 x 10 19 ions cm -2 ). Successive flakes decrease in area, suggesting that eventually a cratered, but stable, surface will result with the only erosion being by the much less effective mechanism of sputtering. (orig.)

  20. Iron and intrinsic deep level states in Ga2O3

    Science.gov (United States)

    Ingebrigtsen, M. E.; Varley, J. B.; Kuznetsov, A. Yu.; Svensson, B. G.; Alfieri, G.; Mihaila, A.; Badstübner, U.; Vines, L.

    2018-01-01

    Using a combination of deep level transient spectroscopy, secondary ion mass spectrometry, proton irradiation, and hybrid functional calculations, we identify two similar deep levels that are associated with Fe impurities and intrinsic defects in bulk crystals and molecular beam epitaxy and hydride vapor phase epitaxi-grown epilayers of β-Ga2O3. First, our results indicate that FeGa, and not an intrinsic defect, acts as the deep acceptor responsible for the often dominating E2 level at ˜0.78 eV below the conduction band minimum. Second, by provoking additional intrinsic defect generation via proton irradiation, we identified the emergence of a new level, labeled as E2*, having the ionization energy very close to that of E2, but exhibiting an order of magnitude larger capture cross section. Importantly, the properties of E2* are found to be consistent with its intrinsic origin. As such, contradictory opinions of a long standing literature debate on either extrinsic or intrinsic origin of the deep acceptor in question converge accounting for possible contributions from E2 and E2* in different experimental conditions.

  1. Lasten ulkovaatteiden kevät-kesämalliston seinäesillepano-ohje : case: Reima Oy

    OpenAIRE

    Järvenoja, Annika

    2014-01-01

    Opinnäytetyö tehtiin Reima Oy:lle. Työn tavoitteena oli kerätä asiakkaiden mielipiteitä lasten ulkovaatteiden seinäesillepanoista. Tutkimuksen pohjalta tehtiin seinäesillepano-ohje kevät-kesämallistolle. Reiman omat myymälät sijaitsevat pääosin Kiinassa, Suomessa ja Venäjällä. Kevät-kesämalliston tuotteiden vaihtelevuus välikausivaatteista ohuisiin aurinkosuojavaatteisiin koettiin myymälässä haasteelliseksi. Tavoitteena on tutkia lisäksi, mistä maiden kulttuurien eroavaisuudet johtuvat, ja mi...

  2. Study of the double charge-changing collision cross-sections of H+, D+, Li+ ions with organic molecules in the energy range 10-50 keV

    International Nuclear Information System (INIS)

    Farrokhi, S.

    1966-01-01

    The variation of the double charge-changing collision cross-sections of H + , D + , Li + ions with organic molecules (CH 4 , C 2 H 6 , C 3 H 8 , C 4 H 10 ) in the energy range 10-50 keV has been studied. Several maximums for σ 1-1 = f(E) have been shown. Their existence should be explained by the different possibilities of dissociating the target-molecules. The position of the maximums, for the H + → H - and D + → D - reactions is in good agreement with that defined by the Massey adiabatic relation. (author) [fr

  3. Collision cross sections of N2 by H+ impact at keV energies within time-dependent density-functional theory

    Science.gov (United States)

    Yu, W.; Gao, C.-Z.; Zhang, Y.; Zhang, F. S.; Hutton, R.; Zou, Y.; Wei, B.

    2018-03-01

    We calculate electron capture and ionization cross sections of N2 impacted by the H+ projectile at keV energies. To this end, we employ the time-dependent density-functional theory coupled nonadiabatically to molecular dynamics. To avoid the explicit treatment of the complex density matrix in the calculation of cross sections, we propose an approximate method based on the assumption of constant ionization rate over the period of the projectile passing the absorbing boundary. Our results agree reasonably well with experimental data and semi-empirical results within the measurement uncertainties in the considered energy range. The discrepancies are mainly attributed to the inadequate description of exchange-correlation functional and the crude approximation for constant ionization rate. Although the present approach does not predict the experiments quantitatively for collision energies below 10 keV, it is still helpful to calculate total cross sections of ion-molecule collisions within a certain energy range.

  4. 10 years of engineering and physics achievements by the Large Helical Device project

    International Nuclear Information System (INIS)

    Yamada, H.; Imagawa, S.; Takeiri, Y.; Kaneko, O.; Mutoh, T.; Mito, T.; Chikaraishi, H.; Hamaguchi, S.; Ida, K.; Igami, H.; Ikeda, K.; Kasahara, H.; Kobayashi, M.; Kubo, S.; Kumazawa, R.; Maekawa, R.; Masuzaki, S.; Miyazawa, J.; Morisaki, T.; Morita, S.

    2009-01-01

    This article reviews 10 years of engineering and physics achievements by the Large Helical Device (LHD) project with emphasis on the latest results. The LHD is the largest magnetic confinement device among diversified helical systems and employs the world's largest superconducting coils. The cryogenic system has been operated for 50,000 h in total without any serious trouble and routinely provides a confining magnetic field up to 2.96 T in steady state. The heating capability to date is 23 MW of NBI, 2.9 MW of ICRF and 2.1 MW of ECH. Negative-ion-based ion sources with the accelerating voltage of 180 keV are used for a tangential NBI with the power of 16 MW. The ICRF system has full steady-state operational capability with 1.6 MW. In these 10 years, operational experience as well as a physics database have been accumulated and the advantages of stable and steady-state features have been demonstrated by the combination of advanced engineering and the intrinsic physical advantage of helical systems in LHD. Highlighted physical achievements are high beta (5% at the magnetic field of 0.425 T), high density (1.1 x 10 21 m -3 at the central temperature of 0.4 keV), high ion temperature (T i of 5.2 keV at 1.5 x 10 19 m -3 ), and steady-state operation (3200 s with 490 kW). These physical parameters have elucidated the potential of net-current free helical plasmas for an attractive fusion reactor. It also should be pointed out that a major part of these engineering and physics achievements is complementary to the tokamak approach and even contributes directly to ITER.

  5. (5/2-→5/2+) 803 keV beta transition in 147Nd

    International Nuclear Information System (INIS)

    Lakshminarayana, S.; Srinivasa Rao, M.; Seshagiri Rao, V.; Sastry, D.L.

    1978-01-01

    The existing experimental results on the 5/2 - →5/2 + 803 keV beta transition in 147 Nd are mutually contradictory to classify it under xi-approximation. To resolve this contradiction, the β-γ directional correlations are performed carefully as a function of energy using a conventional fast-slow coincidence scintillation system. The attenuation factor G 2 in this case turns out to be 0.64 +- 0.05. The results on the longitudinal electron polarization and the shape measurements are combined with the present results and an attempt is made to extract the nuclear matrix elements governing this first forbidden non-unique beta transition following Simm's formalism. Results are discussed based on the final sets of matrix elements. (auth.)

  6. Characterizations of MCP performance in the hard x-ray range (6–25 keV)

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Ming, E-mail: minwu@sandia.gov; Rochau, Greg [Sandia National Laboratory, Albuquerque, New Mexico 87185 (United States); Moy, Ken [Special Technology Laboratories, NSTec, Santa Barbara, California 93111-2335 (United States); Kruschwitz, Craig [National Security Technologies, LLC, Los Alamos Operations, Los Alamos, New Mexico 87544 (United States)

    2014-11-15

    MCP detector performance at hard x-ray energies from 6 to 25 keV was recently investigated using NSLS beamline X15A at BNL. Measurements were made with an NSTec Gen-II (H-CA-65) framing camera, based on a Photonis MCP with ∼10 μm in diameter pores, ∼12 μm center-center spacing, an L/D ratio of 46, and a bias angle of 8°. The MCP characterizations were focused on (1) energy and angle dependent sensitivity, (2) energy and angle dependent spatial resolution, (3) energy dependent gain performance, and (4) energy dependent dynamic range. These measurement corroborated simulation results using a Monte Carlo model that included hard x-ray interactions and the subsequent electron cascade in the MCP.

  7. The interaction between Xe and F in Si (1 0 0) pre-amorphised with 20 keV Xe and implanted with low energy BF{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Werner, M. [Joule Physics Laboratory, Institute of Materials Research, University of Salford, Salford M54WT (United Kingdom)]. E-mail: m.werner@pgr.salford.ac.uk; Berg, J.A. van den [Joule Physics Laboratory, Institute of Materials Research, University of Salford, Salford M54WT (United Kingdom); Armour, D.G. [Joule Physics Laboratory, Institute of Materials Research, University of Salford, Salford M54WT (United Kingdom); Carter, G. [Joule Physics Laboratory, Institute of Materials Research, University of Salford, Salford M54WT (United Kingdom); Feudel, T. [AMD Saxony LLC and Co. KG, Wilschdorfer Landstrasse, 101 D-01109 Dresden (Italy); Herden, M. [AMD Saxony LLC and Co. KG, Wilschdorfer Landstrasse, 101 D-01109 Dresden (Italy); Bersani, M. [ITC IRST, 38050 Povo, Trento (Italy); Giubertoni, D. [ITC IRST, 38050 Povo, Trento (Italy); Bailey, P. [CCLRC Daresbury Laboratory, Daresbury WA44A (United Kingdom); Noakes, T.C.Q. [CCLRC Daresbury Laboratory, Daresbury WA44A (United Kingdom)

    2004-12-15

    The pre-amorphisation of Si by Xe{sup +} ions, before source/drain and extension implants, is an attractive alternative to Ge{sup +} or Si{sup +}, as it produces sharper amorphous/crystalline interfaces. Si (1 0 0) samples pre-amorphised with 20 keV Xe{sup +} to a nominal dose of 2E14 cm{sup -2} were implanted with 1 and 3 keV BF{sub 2} {sup +} to doses of 7E14 cm{sup -2}. Samples were annealed at temperatures ranging from 600 to 1130 deg. C and investigated by medium energy ion scattering (MEIS) and secondary ion mass spectrometry (SIMS). Following annealing, it was observed that implanted Xe has interacted with F originating from the BF{sub 2} {sup +} implant. MEIS studies showed that for all annealing conditions, approximately half of the Xe accumulated at depths of 7 nm for the 1 keV and at 13 nm for the 3 keV BF{sub 2} {sup +} implant. This equates to the end of range of B and F within the amorphous Si. SIMS showed that in the pre-amorphised samples, approximately 10% of the F migrates into the bulk and is trapped at the same depth in a {approx}1:1 ratio to Xe. A small fraction of the implanted B is also trapped. The effect is interpreted in terms of the formation of a defect structure within the amorphised Si, leading to F stabilised Xe bubble or XeF compound formation.

  8. A novel colorimetric method based on copper nanoclusters with intrinsic peroxidase-like for detecting xanthine in serum samples

    Science.gov (United States)

    Yan, Zhengyu; Niu, Qianqian; Mou, Mingyao; Wu, Yi; Liu, Xiaoxuan; Liao, Shenghua

    2017-07-01

    A facile strategy for detecting xanthine in serum samples by copper nanocluster (CuNCs) with high intrinsic peroxidase-like activity was reported. Firstly, a simple, mild and time-saving method for preparing CuNCs was developed, in which dithiothreitol (DTT) and bovine serum albumin (BSA) were used as reductant and stabilizer, respectively. The as-prepared CuNCs exhibited a fluorescence emission at 590 nm with a quantum yield (QY) of approximately 5.29%, the fluorescence intensity of the as-prepared CuNCs exhibited no considerable change when stored under ambient condition with the lifetime is 1.75 μs. Moreover, the as-prepared CuNCs exhibited high intrinsic peroxidase-like activity with lower K m ( K m = 8.90 × 10-6 mol L-1) for H2O2, which indicated that CuNCs have a higher affinity for H2O2. Compared with natural enzyme, the as-synthesized CuNCs are more catalytic stable over a wide range of pH (4.0 13.0) and temperature (4 80 °C). Finally, an indirect method for sensing xanthine was established because xanthine oxidase can catalyse the oxidation of xanthine to produce H2O2. Xanthine could be detected as low as 3.8 × 10-7 mol L-1 with a linear range from 5.0 × 10-7 to 1.0 × 10-4 mol L-1. These results proved that the proposed method is sensitive and accurate and could be successfully applied to the determination of xanthine in the serum sample with satisfaction.

  9. First-principles dynamics treatment of light emission in collisions between alkali-metal atom and noble-gas atom collisions at 10keV

    Science.gov (United States)

    Pacheco, Alexander B.; Reyes, Andrés; Micha, David A.

    2006-12-01

    Collision-induced light emission during the interaction of an alkali-metal atom and a noble-gas atom is treated within a first-principles, or direct, dynamics approach that calculates a time-dependent electric dipole for the whole system, and spectral emission cross sections from its Fourier transform. These cross sections are very sensitive to excited diatomic potentials and a source of information on their shape. The coupling between electronic transitions and nuclear motions is treated with atomic pseudopotentials and an electronic density matrix coupled to trajectories for the nuclei. A recently implemented pseudopotential parametrization scheme is used here for the ground and excited states of the LiHe system, and to calculate state-to-state dipole moments. To verify the accuracy of our new parameters, we recalculate the integral cross sections for the LiHe system in the keV energy regime and obtain agreement with other results from theory and experiment. We further present results for the emission spectrum from 10keV Li(2s)+He collisions, and compare them to experimental values available in the region of light emitted at 300-900nm .

  10. X-ray variability of the BL Lacertae object PKS 2155 - 304 in the 0.1-6 keV range

    International Nuclear Information System (INIS)

    Morini, M.; Chiappetti, L.; Maccagni, D.; Maraschi, L.; Molteni, D.; CNR, Istituto di Fisica Cosmica, Milan, Italy; CNR, Istituto di Fisica Cosmica; Milano Universita, Italy; Palermo Universita, Italy)

    1986-01-01

    Observations of the bright BL Lac object PKS 2155 - 304 obtained at 1-6 keV using the ME argon counters and channel-multiplier array at the focus of the Exosat LE telescope, in conjunction with the 0.05-2-keV-bandpass 3000-A Lexan filter, during a total of 30 h in October-November 1983 and November 1984 are reported. The data are presented in tables and graphs and characterized. Findings discussed include an overall variation of a factor of 10, one factor-of-four increase over 4 h, and maximum luminosity variation dL/dt = 2 x 10 to the 42nd erg/s sq for H = 100 km/s Mpc (corresponding to a lower limit of mass of 10 to the 8th solar mass and a gravitational radius of 3 x 10 to the 13th cm). The implications of these results for theoretical models of the X-ray emission source are considered. 17 references

  11. A compact soft x-ray (0.1–1.2 keV) calibration bench for radiometric measurements using an original versatile Rowland circle grazing incidence monochromator

    Energy Technology Data Exchange (ETDEWEB)

    Hubert, S., E-mail: sebastien.hubert@cea.fr

    2017-05-21

    This paper describes an original Rowland circle grazing incidence spectrometer used as a monochromator for a soft x-ray Manson source in order to calibrate both the source and detectors over the 0.1–1.2 keV spectral range. The originality of the instrument lies on a patented vacuum manipulator which allows the simultaneous boarding of two detectors, one (reference) for measuring the monochromatic radiation and the second to be calibrated. In order to achieve this, the vacuum manipulator is able to interchange, in vacuum, one detector with the other in front of the exit slit of the monochromatizing stage. One purpose of this apparatus was to completely eliminate the intrinsic bremsstrahlung emission of the x-ray diode source and isolate each characteristic line for quantitative detector calibrations. Obtained spectral resolution (Δλ/λ<10{sup −2}) and spectral purity (>98%) fully meet this objective. Initially dimensioned to perform calibration of bulky x-ray cameras unfolded on the Laser MégaJoule Facility, other kinds of detector can be obviously calibrated using this instrument. A brief presentation of the first calibration of an x-ray CCD through its quantum efficiency (QE) measurement is included in this paper as example. Comparison with theoretical model for QE and previous measurements at higher energy are finally presented and discussed.

  12. Properties of the Plasma Surrounding the Global Heliosphere Determined with Voyager 1&2 ions and ENA/INCA Observations at E > 5 keV

    Science.gov (United States)

    Krimigis, S. M.; Dialynas, K.; Mitchell, D. G.; Decker, R. B.; Roelof, E. C.

    2016-12-01

    The basic goal of the proposed Interstellar Mapping and Acceleration Probe (IMAP) is detailed scientific understanding of the Heliosheath (HS) and beyond, a region of space explored in situ by Voyager 1 (V1) since 2004, Voyager 2 (V2) since 2007, and remotely via energetic neutral atoms (ENA) by the Cassini/INCA (5.2-55 keV) since 2003 and IBEX (0.3-6 keV) since 2009. The partial overlap in energies (28 5 keV, the rest residing below that range, resulting in a beta (particle/magnetic pressure) always > 1, typically >10. (2) Based on the ENA-derived hot ion pressures, the interstellar magnetic field (ISMF) was predicted to be more than twice that expected in the literature i.e. similar to what was measured by V1 after crossing the heliopause (B 0.5 nT). (3) The width of the HS in the direction of V1 is 30 AU (predicted by INCA before the V1 HP crossing), but is thought to be larger (40-70 AU) in the southern ecliptic where V2, now 30 AU into the HS, currently travels. We address here the key question of the source of 5-55 keV ENAs that INCA measures. The analysis of INCA all-sky maps from 2003 to 2014 show that the decrease and recovery of ENA in the global heliosphere during this period (declining phase of SC23 and rise of SC24) is similar to that of the ions at V1/V2, consistent with the HS ions being the source of ENA. The close correspondence between ENA and ion spectra (despite the 140 AU distance between V1 and V2) as well as the similarity of ENA spectra over the nose and anti-nose directions, together with the recent V1 measurement of a BISMF 0.5nT, suggest that the global distributions of >5 keV ions in the heliosheath resembles a diamagnetic bubble with no significant tail-like feature (the alternative Parker 1961 model), also consistent with some recent MHD simulations and models.

  13. The total neutron cross section of 58Fe in the energy range 7 to 325 keV

    International Nuclear Information System (INIS)

    Hong, L.D.; Beer, H.; Kaeppeler, F.

    1976-08-01

    The total neutron cross section of 58 Fe has been determined in the energy range 7-325 keV by a transmission measurement using enriched 58 Fe samples. The data have been shape fitted by means of an R-matrix multi-level formalism to extract resonance parameters for s- and l > 0 wave resonances. The s-wave strength function was determined to S 0 = (4.3 +- 1.9) c 10 -4 . (orig.) [de

  14. The decay of 399 KeV isomeric state in 197Pt

    International Nuclear Information System (INIS)

    Soares, J.C.; Melo, A.A.; Gil, F.B.; Dias, H.

    1981-02-01

    The nuclear levels in 197 Pt have been studied from decay of 95.4 min 197 (sup m)Pt. The isomeric state was produced by (n,#betta#) reaction on the enriched 196 Pt. The #betta#-ray spectra have been observed with a hyperpure Ge detector and a large volume Ge(Li) detector. The half lives of the 399 KeV and the 53 KeV states were determined with improved precision. The results are: T1/2 (399 KeV) = 95.41 +- 0.18 min and T1/2(53 KeV) = 16.58 +- 0.17 ns. The g-factor of the 53 Kev 5/2 - state has been measured by the gamma-gamma time differential perturbed angular correlation (TDPAC) method in an external magnetic field of 25,1 kG using the 346 - 53 KeV gamma cascade. The value of g-factor was obtained to be + 0.335 +- 0.010. This result is compared with the known g-factors of the similar states in 195 Pt, and in 197 Hg and 199 Hg and also with the theoretical calculations based on the quasiparticle-phonon coupling scheme. Possibility of using the 346 - 53 KeV gamma cascade in 197 Pt in the future TDPAC studies is discussed. (Author) [pt

  15. Oncogenic transformation in C3H10T1/2 cells by low-energy neutrons.

    Science.gov (United States)

    Miller, R C; Marino, S A; Napoli, J; Shah, H; Hall, E J; Geard, C R; Brenner, D J

    2000-03-01

    Occupational exposure to neutrons typically includes significant doses of low-energy neutrons, with energies below 100 keV. In addition, the normal-tissue dose from boron neutron capture therapy will largely be from low-energy neutrons. Microdosimetric theory predicts decreasing biological effectiveness for neutrons with energies below about 350 keV compared with that for higher-energy neutrons; based on such considerations, and limited biological data, the current radiation weighting factor (quality factor) for neutrons with energies from 10 keV to 100 keV is less than that for higher-energy neutrons. By contrast, some reports have suggested that the biological effectiveness of low-energy neutrons is similar to that of fast neutrons. The purpose of the current work is to assess the relative biological effectiveness of low-energy neutrons for an endpoint of relevance to carcinogenesis: in vitro oncogenic transformation. Oncogenic transformation induction frequencies were determined for C3H10T1/2 cells exposed to two low-energy neutron beams, respectively, with dose-averaged energies of 40 and 70 keV, and the results were compared with those for higher-energy neutrons and X-rays. These results for oncogenic transformation provide evidence for a significant decrease in biological effectiveness for 40 keV neutrons compared with 350 keV neutrons. The 70 keV neutrons were intermediate in effectiveness between the 70 and 350 keV beams. A decrease in biological effectiveness for low-energy neutrons is in agreement with most (but not all) earlier biological studies, as well as microdosimetric considerations. The results for oncogenic transformation were consistent with the currently recommended decreased values for low-energy neutron radiation weighting factors compared with fast neutrons.

  16. Prediction of intrinsic motivation and sports performance using 2 x 2 achievement goal framework.

    Science.gov (United States)

    Li, Chiung-Huang; Chi, Likang; Yeh, Suh-Ruu; Guo, Kwei-Bin; Ou, Cheng-Tsung; Kao, Chun-Chieh

    2011-04-01

    The purpose of this study was to examine the influence of 2 x 2 achievement goals on intrinsic motivation and performance in handball. Participants were 164 high school athletes. All completed the 2 x 2 Achievement Goals Questionnaire for Sport and the Intrinsic Motivation subscale of the Sport Motivation Scale; the coach for each team rated his athletes' overall sports performance. Using simultaneous-regression analyses, mastery-approach goals positively predicted both intrinsic motivation and performance in sports, whereas performance-avoidance goals negatively predicted sports performance. These results suggest that athletes who pursue task mastery and improvement of their competence perform well and enjoy their participation. In contrast, those who focus on avoiding normative incompetence perform poorly.

  17. Excitation of the helium autoionizing states in He/sup +/+He collisions, between 3 and 140 keV

    Energy Technology Data Exchange (ETDEWEB)

    Bordenave-Montesquieu, A.; Gleizes, A.; Benoit-Cattin, P.

    1982-01-01

    The autoionization of the helium atom has been experimentally studied in He/sup +/+He collisions between 3 and 140 keV by electron spectrometry. The excitation of the two collision partners has been considered. Above 10 keV, the shapes and excitation cross sections of the 2s/sup 2/ /sup 1/S, 2s2p /sup 3/P, 2p/sup 2/ /sup 1/D, and 2s2p /sup 1/P are determined by a numerical fitting procedure which is reported in detail; below 10 keV the (/sup 1/D+/sup 1/P), and 2p/sup 2/ /sup 1/S line intensities are obtained by planimetry since important post-collision effects are observed. From the angular distributions measured below 15 keV, the relative sublevel populations are deduced for the 2p/sup 2/ /sup 1/D and 2s2p/sup 1/ P levels and are compared with those obtained by other authors in a coincidence experiment; the excitation processes are then discussed within the quasimolecular-excitation model. For the highest collision energies, the asymmetry of the angular distributions with respect to 90 /sup 0/ as well as the line shapes above 100 keV are interpreted by the occurrence of sudden electronic transitions to the continuum. A comparison of the differential cross sections for emission of electrons by autoionization of the fast and slow particles permits us to show that the quasimolecule model cannot explain what is observed above a collision velocity of about 0.5 a.u. The dependence of the total cross sections against the collision energy is also discussed in terms of an evolution of the excitation mechanism from a quasimolecular to an atomic one; the specific variation of the 2s2p /sup 3/P cross section strengthens this interpretation. These total cross sections are compared with those estimated from earlier H/sup +/+He data published by us; similar autoionization cross-section values are expected for the two systems at high collision velocity.

  18. TIC10/ONC201 synergizes with Bcl-2/Bcl-xL inhibition in glioblastoma by suppression of Mcl-1 and its binding partners in vitro and in vivo.

    Science.gov (United States)

    Karpel-Massler, Georg; Bâ, Maïmouna; Shu, Chang; Halatsch, Marc-Eric; Westhoff, Mike-Andrew; Bruce, Jeffrey N; Canoll, Peter; Siegelin, Markus D

    2015-11-03

    Glioblastoma is the most frequent primary brain tumor in adults. Current therapeutic options are sparse and the prognosis of patients suffering from this disease is grim. Abundance in intratumoral heterogeneity among different deregulated signaling pathways is a hallmark of glioblastoma and likely accounts for its recurrence and resistance to treatment. Glioblastomas harbor a plethora of deregulated pathways driving tumor formation and growth. In this study, we show that TIC10/ONC201, a promising compound that is currently in planned clinical development, along with Bcl-2/Bcl-xL inhibition by ABT263 yields a strong synergistic antiproliferative effect on pediatric, adult, proneural glioblastoma and glioma stem-like cells. On the molecular level, treatment with TIC10/ONC201 results in a posttranslational decrease of the anti-apoptotic Bcl-2 family member, myeloid cell leukemia 1 (Mcl-1), through modulation of the chaperone Bag3 and the deubiquitinase Usp9X. Consistently, the combination treatment of TIC10/ONC201 and ABT263 required the presence of functional BAX and BAK to drive intrinsic apoptosis, but is surprisingly independent of the extrinsic apoptotic pathway. Moreover, the expression of Noxa protein was required for efficient apoptosis induction by TIC10/ONC201 and ABT263. Importantly, the drug combination of TIC10/ONC201 and the BH3-mimetic, ABT263, led to a regression of tumors in vivo, without any notable toxicity and side effects. Overall, TIC10/ONC201 along with Bcl-2/Bcl-xL inhibition holds significant promise as a novel potential approach for the treatment of recalcitrant tumors such as glioblastoma.

  19. Measurement of 2-5 keV x-ray emission from laser-target interactions by using fluor-MCP and CsI-XRD detectors

    International Nuclear Information System (INIS)

    Lee, P.H.Y.; Tirsell, K.G.; Leipelt, G.R.; Laird, W.B.

    1981-01-01

    For inertial confinement fusion plasma diagnostics, x-ray diode (XRD) detectors using conventional cathodes are not sensitive enough to measure x-rays above approx. 1.5 keV. However, for laser driver fusion targets, x-rays in the range of 2 to 5 keV are important because of their mobility in the target. We have successfully used fluor-microchannel plate (MCP) detectors to obtain absolute x-ray measurements in the 2 to 5 keV range. Recent data obtained from experiments on the Shiva laser system are presented. In addition, designs for a variety of channels in the range using fluor-MCP and CsI-XRD's above 1.5 keV will be discussed

  20. Study of the Jet-Pini 160 keV optics in a single beamlet system

    International Nuclear Information System (INIS)

    Bottiglioni, F.; Bussac, J.P.; Jequier, F.

    1986-01-01

    The optics of the prototype of the extended performances PINI-injector, for the operation at 160 keV in D 2 , has been studied and tested on the separate test stand L.E.O., enabling experiments on a single beamlet. The results of the optics computations and of the experimentation on the beamlet are presented and discussed, namely as far profiles, divergence and steering are concerned

  1. Charge yield for cobalt-60 and 10-keV x-ray irradiations of MOS devices

    International Nuclear Information System (INIS)

    Shaneyfelt, M.R.; Fleetwood, D.M.; Schwank, J.R.; Hughes, K.L.

    1991-01-01

    In this paper the radiation response of MOS devices exposed to 60 Co and low-energy (∼10 keV) x-ray irradiation is evaluated as a function of electric field during exposure. Improved charge yield estimates are obtained for 60 Co irradiations at fields below 1 MV/cm by matching voltage shifts due to oxide-trap and interface-trap charge to an E -0.55 electric field dependence. Combining these improved charge yield estimates and calculated dose enhancement factors, the relative response of x-ray to 60 Co irradiations is accurately predicted for oxide electric fields from 0.03 MV/cm to 5.0 MV/cm. The ability to predict the relative response of x-ray to 60 Co irradiations should speed acceptance of x-ray testers as a hardness assurance tool

  2. A 7.2 keV spherical x-ray crystal backlighter for two-frame, two-color backlighting at Sandia's Z Pulsed Power Facility

    Science.gov (United States)

    Schollmeier, M. S.; Knapp, P. F.; Ampleford, D. J.; Harding, E. C.; Jennings, C. A.; Lamppa, D. C.; Loisel, G. P.; Martin, M. R.; Robertson, G. K.; Shores, J. E.; Smith, I. C.; Speas, C. S.; Weis, M. R.; Porter, J. L.; McBride, R. D.

    2017-10-01

    Many experiments on Sandia National Laboratories' Z Pulsed Power Facility—a 30 MA, 100 ns rise-time, pulsed-power driver—use a monochromatic quartz crystal backlighter system at 1.865 keV (Si He α ) or 6.151 keV (Mn He α ) x-ray energy to radiograph an imploding liner (cylindrical tube) or wire array z-pinch. The x-ray source is generated by the Z-Beamlet laser, which provides two 527-nm, 1 kJ, 1-ns laser pulses. Radiographs of imploding, thick-walled beryllium liners at convergence ratios CR above 15 [ C R = r i ( 0 ) / r i ( t ) ] using the 6.151-keV backlighter system were too opaque to identify the inner radius r i of the liner with high confidence, demonstrating the need for a higher-energy x-ray radiography system. Here, we present a 7.242 keV backlighter system using a Ge(335) spherical crystal with the Co He α resonance line. This system operates at a similar Bragg angle as the existing 1.865 keV and 6.151 keV backlighters, enhancing our capabilities for two-color, two-frame radiography without modifying the system integration at Z. The first data taken at Z include 6.2-keV and 7.2-keV two-color radiographs as well as radiographs of low-convergence (CR about 4-5), high-areal-density liner implosions.

  3. Subshell resolved L shell ionization of Bi and U induced by 16 - 45 keV electrons

    International Nuclear Information System (INIS)

    Rahangdale, Hitesh; Das, Pradipta K.; Saha, S.; Mitra, D.

    2015-01-01

    Electron induced inner-shell ionization is important for both fundamental and applied research. Ionization of outer atomic energy levels has been studied extensively than for inner levels. Knowledge of inner shell ionization cross sections is important in X-ray and Auger electron spectroscopy and in the fields of astrophysics, plasma physics, surface science and many more. At electron impact energies near the atomic binding energies the distortion of the wave functions from plane wave towards a spherical wave, due to the electrostatic field of the atoms, needs to be considered. The distorted wave Born approximation (DWBA) calculations, taking relativistic effects and exchange interaction into account, is used to estimate the K, L and M-shell ionization cross-section for the atoms. Earlier experiments on electron impact ionization studies focused mainly on K-shell ionization cross-section, while L and M-shell ionization data were hardly reported. A review of the existing L-shell ionization cross-section data shows that, while the X-ray production cross-sections by electron impact were reported quite a few times, the reporting of subshell resolved ionization cross-sections were rarely found near the ionization threshold region. In the present work, we have measured the X ray production cross-sections of different L lines of Bi and U induced by 16-45 keV electrons and converted the obtained values to the subshell specific ionization cross-sections. The experimental data are compared with the theoretical calculations based on the (DWBA) obtained from PENELOPE. To the best of our knowledge, the subshell resolved electron induced ionization cross-sections for the L-shell of Bi and U are reported here for the first time at the energy values near the corresponding ionization threshold. (author)

  4. Measurement of the x-ray mass-attenuation coefficients of gold, derived quantities between 14 keV and 21 keV and determination of the bond lengths of gold

    International Nuclear Information System (INIS)

    Glover, J L; Chantler, C T; Barnea, Z; Rae, N A; Tran, C Q

    2010-01-01

    The x-ray mass-attenuation coefficients of gold are measured at 91 energies between 14 keV and 21 keV using synchrotron radiation. The measurements are accurate to between 0.08% and 0.1%. The photoelectric mass-absorption coefficients and the imaginary component of the form factors of gold are also determined. The results include the L I edge and are the most accurate and extensive gold dataset available in this energy range. An analysis of the L I edge XAFS showed excellent agreement between the measured and simulated XAFS and yielded highly accurate values of the bond lengths of gold. When our results are compared with earlier measurements and with predictions of major theoretical tabulations, significant discrepancies are noted. The comparison raises questions about the nature of discrepancies between experimental and theoretical values of mass-attenuation coefficients.

  5. Atomic scattering factor of the ASTRO-H (Hitomi) SXT reflector around the gold's L edges

    DEFF Research Database (Denmark)

    Kikuchi, Naomichi; Kurashima, Sho; Ishida, Manabu

    2016-01-01

    The atomic scattering factor in the energy range of 11.2-15.4 keV for the ASTRO-H Soft X-ray Telescope (SXT) is reported. The large effective area of the SXT makes use of photon spectra above 10 keV viable, unlike most other X-ray satellites with total-reflection mirror optics. Presence of gold's L-edges...... in the energy band is a major issue, as it complicates the function of the effective area. In order to model the area, the reflectivity measurements in the 11.2-15.4 keV band with the energy pitch of 0.4-0.7 eV were made in the synchrotron beamline Spring-8 BL01B1. We obtained atomic scattering factors f1 and f......2 by the curve fitting to the reflectivities of our witness sample. The edges associated with the L-I, II, and III transitions are identified, of which the depths are found to be roughly 60% shallower than those expected from the Henke's atomic scattering factor....

  6. The Galactic 511 keV line: analysis and interpretation of Integral observations

    International Nuclear Information System (INIS)

    Lonjou, V.

    2005-09-01

    Ever since the discovery of the 511 keV annihilation line emission from the galactic center region in the late seventies, the origin of galactic positrons has been the topic of a vivid scientific debate. It is also one of the prime scientific objectives of the imaging spectrometer SPI on board ESA's INTEGRAL observatory. In this thesis first a description of the most important SPI sub-system is given - the detector plane. Procedures for detector energy calibration and detector degradation analysis are developed. The determination of instrumental background models, a crucial aspect of data analysis, is elaborated. These background models are then applied to deriving sky maps and spectra of unprecedented quality of the Galactic positron annihilation radiation. The emission is centered on the galactic center with a spatial resolution of 8 degrees (FWHM), a second spatial component appears clearly: the galactic disc. The ray energy has been measured with unprecedented accuracy: 511.0 ± 0.03 keV for a full width at half maximum (FWHM) of 2.07 ± 0.1 keV. The total galactic flux ranges from 1.09 to 2.43 10 -3 ph.cm -2 .s -1 including uncertainties on spatial distribution. Finally, the implications of these observations for the production of positrons by various Galactic populations are discussed

  7. Monte Carlo calculation for the development of a BNCT neutron source (1eV-10KeV) using MCNP code.

    Science.gov (United States)

    El Moussaoui, F; El Bardouni, T; Azahra, M; Kamili, A; Boukhal, H

    2008-09-01

    Different materials have been studied in order to produce the epithermal neutron beam between 1eV and 10KeV, which are extensively used to irradiate patients with brain tumors such as GBM. For this purpose, we have studied three different neutrons moderators (H(2)O, D(2)O and BeO) and their combinations, four reflectors (Al(2)O(3), C, Bi, and Pb) and two filters (Cd and Bi). Results of calculation showed that the best obtained assembly configuration corresponds to the combination of the three moderators H(2)O, BeO and D(2)O jointly to Al(2)O(3) reflector and two filter Cd+Bi optimize the spectrum of the epithermal neutron at 72%, and minimize the thermal neutron to 4% and thus it can be used to treat the deep tumor brain. The calculations have been performed by means of the Monte Carlo N (particle code MCNP 5C). Our results strongly encourage further studying of irradiation of the head with epithermal neutron fields.

  8. Prostate health index significantly reduced unnecessary prostate biopsies in patients with PSA 2-10 ng/mL and PSA >10 ng/mL: Results from a Multicenter Study in China.

    Science.gov (United States)

    Na, Rong; Ye, Dingwei; Qi, Jun; Liu, Fang; Helfand, Brian T; Brendler, Charles B; Conran, Carly A; Packiam, Vignesh; Gong, Jian; Wu, Yishuo; Zheng, Siqun L; Mo, Zengnan; Ding, Qiang; Sun, Yinghao; Xu, Jianfeng

    2017-08-01

    The performance of prostate health index (phi) in predicting prostate biopsy outcomes has been well established for patients with prostate-specific antigen (PSA) values between 2 and 10 ng/mL. However, the performance of phi remains unknown in patients with PSA >10 ng/mL, the vast majority in Chinese biopsy patients. We aimed to assess the ability of phi to predict prostate cancer (PCa) and high-grade disease (Gleason Score ≥7) on biopsy in a Chinese population. This is a prospective, observational, multi-center study of consecutive patients who underwent a transrectal ultrasound guided prostate biopsy at four hospitals in Shanghai, China from August 2013 to December 2014. In the cohort of 1538 patients, the detection rate of PCa was 40.2%. phi had a significantly better predictive performance for PCa than total PSA (tPSA). The areas under the receiver operating characteristic curve (AUC) were 0.90 and 0.79 for phi and tPSA, respectively, P 10 ng/mL (N = 838, 54.5%). The detection rates of PCa were 35.9% and 57.7% in patients with tPSA 10.1-20 and 20.1-50 ng/mL, respectively. The AUCs of phi (0.79 and 0.89, for these two groups, respectively) were also significantly higher than tPSA (0.57 and 0.63, respectively), both P 10 ng/mL). © 2017 Wiley Periodicals, Inc.

  9. Compact Source of Electron Beam with Energy of 200 kEv and Average Power of 2 kW

    CERN Document Server

    Kazarezov, Ivan; Balakin, Vladimir E; Bryazgin, Alex; Bulatov, Alexandre; Glazkov, Ivan; Kokin, Evgeny; Krainov, Gennady; Kuznetsov, Gennady I; Molokoedov, Andrey; Tuvik, Alfred

    2005-01-01

    The paper describes a compact electron beam source with average electron energy of 200 keV. The source operates with pulse power up to 2 MW under average power not higher than 2 kW, pulsed beam current up to 10 A, pulse duration up to 2 mks, and repetition rate up to 5 kHz. The electron beam is extracted through aluminium-beryllium alloy foil. The pulse duration and repetition rate can be changed from control desk. High-voltage generator for the source with output voltage up to 220 kV is realized using the voltage-doubling circuit which consists of 30 sections. The insulation type - gas, SF6 under pressure of 8 atm. The cooling of the foil supporting tubes is provided by a water-alcohol mixture from an independent source. The beam output window dimensions are 180?75 mm, the energy spread in the beam +10/-30%, the source weight is 80 kg.

  10. Synthesis of gold and silver nanoparticles by electron irradiation at 5-15 keV energy

    Energy Technology Data Exchange (ETDEWEB)

    Mahapatra, S K; Bogle, K A; Dhole, S D; Bhoraskar, V N [Microtron Accelerator Laboratory, Department of Physics, University of Pune, Pune-411007 (India)

    2007-04-04

    Thin coatings ({approx}10 {mu}m) made from a mixture of polyvinyl alcohol (PVA) and HAuCl{sub 4} or PVA and AgNO{sub 3} on quartz plates were irradiated with 5-15 keV electrons, at room temperature. The electron energy was varied from coating to coating in the range of 5-15 keV, but electron fluence was kept constant at {approx}10{sup 15} e cm{sup -2}. Samples were characterized by the UV-vis, XRD, SEM and TEM techniques. The plasmon absorption peaks at {approx}511 and {approx}442 nm confirmed the formation of gold and silver nanoparticles in the respective electron-irradiated coatings. The XRD, SEM and TEM measurements reveal that the average size of the particles could be tailored in the range of 130-50 nm for gold and from 150-40 nm for silver by varying the electron energy in the range of 5-15 keV. These particles of gold and silver embedded in the polymer could also be separated by dissolving the coatings in distilled water.

  11. NuSTAR OBSERVATIONS OF THE COMPTON-THICK ACTIVE GALACTIC NUCLEUS AND ULTRALUMINOUS X-RAY SOURCE CANDIDATE IN NGC 5643

    International Nuclear Information System (INIS)

    Annuar, A.; Gandhi, P.; Alexander, D. M.; Lansbury, G. B.; Moro, A. Del; Arévalo, P.; Ballantyne, D. R.; Baloković, M.; Brightman, M.; Harrison, F. A.; Bauer, F. E.; Boggs, S. E.; Craig, W. W.; Brandt, W. N.; Christensen, F. E.; Hailey, C. J.; Hickox, R. C.; Matt, G.; Puccetti, S.; Ricci, C.

    2015-01-01

    We present two Nuclear Spectroscopic Telescope Array (NuSTAR) observations of the local Seyfert 2 active galactic nucleus (AGN) and an ultraluminous X-ray source (ULX) candidate in NGC 5643. Together with archival data from Chandra, XMM-Newton, and Swift-BAT, we perform a high-quality broadband spectral analysis of the AGN over two decades in energy (∼0.5–100 keV). Previous X-ray observations suggested that the AGN is obscured by a Compton-thick (CT) column of obscuring gas along our line of sight. However, the lack of high-quality ≳10 keV observations, together with the presence of a nearby X-ray luminous source, NGC 5643 X–1, have left significant uncertainties in the characterization of the nuclear spectrum. NuSTAR now enables the AGN and NGC 5643 X–1 to be separately resolved above 10 keV for the first time and allows a direct measurement of the absorbing column density toward the nucleus. The new data show that the nucleus is indeed obscured by a CT column of N H ≳ 5 × 10 24 cm −2 . The range of 210 keV absorption-corrected luminosity inferred from the best-fitting models is L 210,int = (0.8–1.7) × 10 42 erg s −1 , consistent with that predicted from multiwavelength intrinsic luminosity indicators. In addition, we also study the NuSTAR data for NGC 5643 X–1 and show that it exhibits evidence of a spectral cutoff at energy E ∼ 10 keV, similar to that seen in other ULXs observed by NuSTAR. Along with the evidence for significant X-ray luminosity variations in the 3–8 keV band from 2003 to 2014, our results further strengthen the ULX classification of NGC 5643 X–1

  12. Hydrodynamic simulations of a combined hydrogen, helium thermonuclear runaway on a 10-km neutron star

    International Nuclear Information System (INIS)

    Starrfield, S.; Kenyon, S.; Truran, J.W.; Sparks, W.M.

    1983-01-01

    We have used a Lagrangian, hydrodynamic stellar-evolution computer code to evolve a thermonuclear runaway in the accreted hydrogen rich envelope of a 1.0M, 10-km neutron star. Our simulation produced an outburst which lasted about 2000 sec and peak effective temperature was 3 keV. The peak luminosity exceeded 2 x 10 5 L. A shock wave caused a precursor in the light curve which lasted 10 -5 sec

  13. Genetic variability in L1 and L2 genes of HPV-16 and HPV-58 in Southwest China.

    Directory of Open Access Journals (Sweden)

    Yaofei Yue

    Full Text Available HPV account for most of the incidence of cervical cancer. Approximately 90% of anal cancers and a smaller subset (<50% of other cancers (oropharyngeal, penile, vaginal, vulvar are also attributed to HPV. The L1 protein comprising HPV vaccine formulations elicits high-titre neutralizing antibodies and confers type restricted protection. The L2 protein is a promising candidate for a broadly protective HPV vaccine. In our previous study, we found the most prevalent high-risk HPV infectious serotypes were HPV-16 and HPV-58 among women of Southwest China. To explore gene polymorphisms and intratypic variations of HPV-16 and HPV-58 L1/L2 genes originating in Southwest China, HPV-16 (L1: n = 31, L2: n = 28 and HPV-58 (L1: n = 21, L2: n = 21 L1/L2 genes were sequenced and compared to others described and submitted to GenBank. Phylogenetic trees were then constructed by Neighbor-Joining and the Kimura 2-parameters methods (MEGA software, followed by an analysis of the diversity of secondary structure. Then selection pressures acting on the L1/L2 genes were estimated by PAML software. Twenty-nine single nucleotide changes were observed in HPV-16 L1 sequences with 16/29 non-synonymous mutations and 13/29 synonymous mutations (six in alpha helix and two in beta turns. Seventeen single nucleotide changes were observed in HPV-16 L2 sequences with 8/17 non-synonymous mutations (one in beta turn and 9/17 synonymous mutations. Twenty-four single nucleotide changes were observed in HPV-58 L1 sequences with 10/24 non-synonymous mutations and 14/24 synonymous mutations (eight in alpha helix and four in beta turn. Seven single nucleotide changes were observed in HPV-58 L2 sequences with 4/7 non-synonymous mutations and 3/7 synonymous mutations. The result of selective pressure analysis showed that most of these mutations were of positive selection. This study may help understand the intrinsic geographical relatedness and biological differences of HPV-16/HPV-58 and

  14. Universal empirical fit to L-shell X-ray production cross sections in ionization by protons

    Science.gov (United States)

    Lapicki, G.; Miranda, J.

    2018-01-01

    A compilation published in 2014, with a recent 2017 update, contains 5730 experimental total L-shell X-ray production cross sections (XRPCS). The database covers an energy range from 10 keV to 1 GeV, and targets from 18Ar to 95Am. With only two adjustable parameters, universal fit to these data normalized to XRPCS calculated at proton velocity v1 equal to the electron velocity in the L-shell v2L, is obtained in terms of a single ratio of v1/v2L. This fit reproduces 97% of the compiled XRPCS to within a factor of 2.

  15. L1000CDS2: LINCS L1000 characteristic direction signatures search engine.

    Science.gov (United States)

    Duan, Qiaonan; Reid, St Patrick; Clark, Neil R; Wang, Zichen; Fernandez, Nicolas F; Rouillard, Andrew D; Readhead, Ben; Tritsch, Sarah R; Hodos, Rachel; Hafner, Marc; Niepel, Mario; Sorger, Peter K; Dudley, Joel T; Bavari, Sina; Panchal, Rekha G; Ma'ayan, Avi

    2016-01-01

    The library of integrated network-based cellular signatures (LINCS) L1000 data set currently comprises of over a million gene expression profiles of chemically perturbed human cell lines. Through unique several intrinsic and extrinsic benchmarking schemes, we demonstrate that processing the L1000 data with the characteristic direction (CD) method significantly improves signal to noise compared with the MODZ method currently used to compute L1000 signatures. The CD processed L1000 signatures are served through a state-of-the-art web-based search engine application called L1000CDS 2 . The L1000CDS 2 search engine provides prioritization of thousands of small-molecule signatures, and their pairwise combinations, predicted to either mimic or reverse an input gene expression signature using two methods. The L1000CDS 2 search engine also predicts drug targets for all the small molecules profiled by the L1000 assay that we processed. Targets are predicted by computing the cosine similarity between the L1000 small-molecule signatures and a large collection of signatures extracted from the gene expression omnibus (GEO) for single-gene perturbations in mammalian cells. We applied L1000CDS 2 to prioritize small molecules that are predicted to reverse expression in 670 disease signatures also extracted from GEO, and prioritized small molecules that can mimic expression of 22 endogenous ligand signatures profiled by the L1000 assay. As a case study, to further demonstrate the utility of L1000CDS 2 , we collected expression signatures from human cells infected with Ebola virus at 30, 60 and 120 min. Querying these signatures with L1000CDS 2 we identified kenpaullone, a GSK3B/CDK2 inhibitor that we show, in subsequent experiments, has a dose-dependent efficacy in inhibiting Ebola infection in vitro without causing cellular toxicity in human cell lines. In summary, the L1000CDS 2 tool can be applied in many biological and biomedical settings, while improving the extraction of

  16. Cryogenic trapping of keV ion beams at the CSR prototype

    Energy Technology Data Exchange (ETDEWEB)

    Menk, Sebastian; Blaum, Klaus; Froese, Michael; Grieser, Manfred; Lange, Michael; Orlov, Dimitry; Sieber, Thomas; Hahn, Robert von; Varju, Jozef; Wolf, Andreas [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Heber, Oded; Rappaport, Michael; Zajfman, Daniel [Weizmann Institut of Science, Rehovot (Israel)

    2009-07-01

    A Cryogenic Trap for Fast ion beams (CTF) was built to explore cooling techniques and test thermal decoupling of ion optics for the development of the electrostatic Cryogenic Storage Ring (CSR). These challenging projects will lead to a new experimental field of atomic and molecular physics with keV ion beams. The cold conditions of 2-10 K minimize the blackbody radiation field and are expected to lead to extremely low restgas densities (equivalent pressure at room temperature {approx}10{sup -13} mbar) which result in long storage lifetimes and for molecular ions to radiative cooling to their ro-vibrational ground states. The CTF consists of two stacks of electrostatic mirror electrodes allowing the storage of up to 20 keV ion beams. Cryogenic ion beam storage has been realized with this device using a liquid helium refrigeration system to cool down the experimental trapping area to few-Kelvin cryogenic temperatures and experiments with cryogenically trapped molecular nitrogen ions have been performed to verify the low vacuum conditions by measuring their storage lifetimes.

  17. The characteristic pitch angle distributions of 1 eV to 600 keV protons near the equator based on Van Allen Probes observations

    Science.gov (United States)

    Yue, C.; Bortnik, J.; Thorne, R. M.; Ma, Q.; An, X.; Chappell, C. R.; Gerrard, A. J.; Lanzerotti, L. J.; Shi, Q.

    2017-12-01

    Understanding the source and loss processes of various plasma populations is greatly aided by having accurate knowledge of their pitch angle distributions (PADs). Here, we statistically analyze 1 eV to 600 keV hydrogen (H+) PADs near the geomagnetic equator in the inner magnetosphere based on Van Allen Probes measurements, to comprehensively investigate how the H+ PADs vary with different energies, magnetic local times (MLTs), L-shells, and geomagnetic conditions. Our survey clearly indicates four distinct populations with different PADs: (1) a pancake distribution of the plasmaspheric H+ at low L-shells except for dawn sector; (2) a bi-directional field-aligned distribution of the warm plasma cloak; (3) pancake or isotropic distributions of ring current H+; (4) radiation belt particles show pancake, butterfly and isotropic distributions depending on their energy, MLT and L-shell. Meanwhile, the pancake distribution of ring current H+ moves to lower energies as L-shell increases which is primarily caused by adiabatic transport. Furthermore, energetic H+ (> 10 keV) PADs become more isotropic following the substorm injections, indicating wave-particle interactions. The radiation belt H+ butterfly distributions are identified in a narrow energy range of 100 5), which are less significant during quiet times and extend from dusk to dawn sector through midnight during substorms. The different PADs near the equator provide clues of the underlying physical processes that produce the dynamics of these different populations.

  18. Autoionisation of N/sup 5 +/ (nln'l') with n = 2,3,4 and n' >= n measured by electron spectrometry in collisions of N/sup 7 +/ with He and H/sub 2/, at 4. 9 keV amu/sup -1/

    Energy Technology Data Exchange (ETDEWEB)

    Bordenave-Montesquieu, A.; Benoit-Cattin, P.; Gleizes, A.; Marrakchi, A.I.; Dousson, S.; Hitz, D. (CEA Centre d' Etudes Nucleaires de Grenoble, 38 (France))

    1984-03-14

    a spectroscopic investigation of electrons coming from autoionising states N/sup 5 +/(nln'l'), with n=2,3,4 and n' >= n, of the fast ion has been made at 11.6/sup 0/ and 4.9 keV amu/sup -1/. Only exothermic reactions are observed. It is shown that the ionisation potential of the target has a strong influence on the more probable values of n and n'. In N/sup 7 +/-He collisions, the n=3, n'=3 configurations are the more excited. In N/sup 7 +/-H/sub 2/, the capture process is less selective since n=3, n' > 3 and also n=4, n' >= 4 configurations are strongly populated. In all these cases, the residual N/sup 6 +/ ion is left in an excited state (n=2 or 3). The n=2, n' > 2 excitation probability is found to be much smaller for the two collisional systems.

  19. Fluorescent L-radiation and the. gamma. -radiation of ionium

    Energy Technology Data Exchange (ETDEWEB)

    Riou, M

    1949-02-21

    Irene Curie, Compt. rend. 227, 1225(1948), has shown that the ..gamma..-radiation of ionium is accompanied by a soft radiation that can be identified with the fluorescent L-lines of radium. The present author submitted these radiations to a further study, using as a source a ionium--thorium mixture, (100 mg of hydrate), containing 9% ionium. The Geiger--Mueller counters had 5 mg/cm/sup 2/ aluminum ends and were filled with alcohol + xenon at 10-21 cm Hg. The absorption curves in Cu, Mo, and Ag showed that the energy of the soft radiation was about 14 keV. For the separation of lines, the selective absorption was determined in elements from Z = 28 to Z = 53. The results confirmed the attribution of the spectrum to the L-radiation of Ra. Similar measurements on radioactinium revealed the same lines with approximately the same intensities. In both cases a radium isotope is formed: /sub 90/Th/sup 230/(Io) ..-->.. /sub 88/Ra/sup 226/ ..-->.. ..cap alpha.., /sub 90/Th/sup 227/ (RaAc) ..-->.. /sub 88/Ra/sup 223/ (AcX) + ..cap alpha... The identity of the spectra shows that the atomic number of the formed atom alone determines the L-spectrum, and that in both cases the L level is excited as a result of an internal conversion of ..gamma..-lines: the line 68 keV in the case of ionium, eight lines 26-100 keV in that of radioactinium. On the basis of the intensities found, the relative numbers of photons corresponding to the levels L/sub I/, L/sub II/, and L/sub III/ could be calculated; they are L/sub I/:L/sub II/:L/sub III/ = 50:20:26. The ..gamma..-rays of ionium, as determined from the absorption in Cu, Ta, and Pb, are 68 and 200 kev. By assuming that the efficiency of the counters is equal to 1 - exp (-m..mu../rho), (where m is the efficient superficial mass of xenon, and ..mu../rho is the absorption coefficient in xenon), the intensities of the L- and ..gamma..-radiations of ionium can be given in terms of numbers of quanta per 100 disintegrations.

  20. Sputtering of Thick Deuterium Films by KeV Electrons

    DEFF Research Database (Denmark)

    Thestrup Nielsen, Birgitte; Svendsen, Winnie Edith; Schou, Jørgen

    1994-01-01

    Sputtering of thick films of solid deuterium up to several μm by keV electrons is reported for the first time. The sputtering yield increases within a narrow range of thicknesses around 1.6 μm by about 2 orders of magnitude for 1.5 keV electrons. A similar behavior has not been observed for ion...

  1. Multiple capture investigated by coincident electron spectroscopy in X{sup 7+}+Ar, at 70 keV

    Energy Technology Data Exchange (ETDEWEB)

    Moretto-Capelle, P.; Bordenave-Montesquieu, D.; Bordenave-Montesquieu, A. [Universite Paul Sabatier, Toulouse (France). Lab. Collisions-Agregats-Reactivite

    1999-11-01

    The multiple electron capture in N{sup 7+} + Ar and F{sup 7+}(1s{sup 2}) + Ar systems is investigated at 70 keV with a new electron-recoil ion charge coincidence experiment. The whole electron energy range has been studied. Up to six electrons are found to be captured into autoionizing states. The recoil ion charge distribution associated with the emission of electrons is similar for both systems and found to be in good agreement with the prediction of Niehaus`s model roughly adapted to take into account autoionizing cascades. New findings for the coincident double and triple captures are briefly discussed. A capture of an inner L-shell electron of Ar into the K-shell of the projectile is also observed in N{sup 7+} + Ar collisions. (orig.) 10 refs.

  2. The S100A10 subunit of the annexin A2 heterotetramer facilitates L2-mediated human papillomavirus infection.

    Science.gov (United States)

    Woodham, Andrew W; Da Silva, Diane M; Skeate, Joseph G; Raff, Adam B; Ambroso, Mark R; Brand, Heike E; Isas, J Mario; Langen, Ralf; Kast, W Martin

    2012-01-01

    Mucosotropic, high-risk human papillomaviruses (HPV) are sexually transmitted viruses that are causally associated with the development of cervical cancer. The most common high-risk genotype, HPV16, is an obligatory intracellular virus that must gain entry into host epithelial cells and deliver its double stranded DNA to the nucleus. HPV capsid proteins play a vital role in these steps. Despite the critical nature of these capsid protein-host cell interactions, the precise cellular components necessary for HPV16 infection of epithelial cells remains unknown. Several neutralizing epitopes have been identified for the HPV16 L2 minor capsid protein that can inhibit infection after initial attachment of the virus to the cell surface, which suggests an L2-specific secondary receptor or cofactor is required for infection, but so far no specific L2-receptor has been identified. Here, we demonstrate that the annexin A2 heterotetramer (A2t) contributes to HPV16 infection and co-immunoprecipitates with HPV16 particles on the surface of epithelial cells in an L2-dependent manner. Inhibiting A2t with an endogenous annexin A2 ligand, secretory leukocyte protease inhibitor (SLPI), or with an annexin A2 antibody significantly reduces HPV16 infection. With electron paramagnetic resonance, we demonstrate that a previously identified neutralizing epitope of L2 (aa 108-120) specifically interacts with the S100A10 subunit of A2t. Additionally, mutation of this L2 region significantly reduces binding to A2t and HPV16 pseudovirus infection. Furthermore, downregulation of A2t with shRNA significantly decreases capsid internalization and infection by HPV16. Taken together, these findings indicate that A2t contributes to HPV16 internalization and infection of epithelial cells and this interaction is dependent on the presence of the L2 minor capsid protein.

  3. The S100A10 subunit of the annexin A2 heterotetramer facilitates L2-mediated human papillomavirus infection.

    Directory of Open Access Journals (Sweden)

    Andrew W Woodham

    Full Text Available Mucosotropic, high-risk human papillomaviruses (HPV are sexually transmitted viruses that are causally associated with the development of cervical cancer. The most common high-risk genotype, HPV16, is an obligatory intracellular virus that must gain entry into host epithelial cells and deliver its double stranded DNA to the nucleus. HPV capsid proteins play a vital role in these steps. Despite the critical nature of these capsid protein-host cell interactions, the precise cellular components necessary for HPV16 infection of epithelial cells remains unknown. Several neutralizing epitopes have been identified for the HPV16 L2 minor capsid protein that can inhibit infection after initial attachment of the virus to the cell surface, which suggests an L2-specific secondary receptor or cofactor is required for infection, but so far no specific L2-receptor has been identified. Here, we demonstrate that the annexin A2 heterotetramer (A2t contributes to HPV16 infection and co-immunoprecipitates with HPV16 particles on the surface of epithelial cells in an L2-dependent manner. Inhibiting A2t with an endogenous annexin A2 ligand, secretory leukocyte protease inhibitor (SLPI, or with an annexin A2 antibody significantly reduces HPV16 infection. With electron paramagnetic resonance, we demonstrate that a previously identified neutralizing epitope of L2 (aa 108-120 specifically interacts with the S100A10 subunit of A2t. Additionally, mutation of this L2 region significantly reduces binding to A2t and HPV16 pseudovirus infection. Furthermore, downregulation of A2t with shRNA significantly decreases capsid internalization and infection by HPV16. Taken together, these findings indicate that A2t contributes to HPV16 internalization and infection of epithelial cells and this interaction is dependent on the presence of the L2 minor capsid protein.

  4. Anisotropy of electrical conductivity in dc due to intrinsic defect formation in α-Al{sub 2}O{sub 3} single crystal implanted with Mg ions

    Energy Technology Data Exchange (ETDEWEB)

    Tardío, M., E-mail: mtardio@fis.uc3m.es [Departamento de Física, Escuela Politécnica Superior, Universidad Carlos III, Avda. de la Universidad, 30, 28911 Leganés (Madrid) (Spain); Egaña, A.; Ramírez, R.; Muñoz-Santiuste, J.E. [Departamento de Física, Escuela Politécnica Superior, Universidad Carlos III, Avda. de la Universidad, 30, 28911 Leganés (Madrid) (Spain); Alves, E. [Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, 2695-066 Bobadela (Portugal)

    2016-07-15

    The electrical conductivity in α-Al{sub 2}O{sub 3} single crystals implanted with Mg ions in two different crystalline orientations, parallel and perpendicular to c axis, was investigated. The samples were implanted at room temperature with energies of 50 and 100 keV and fluences of 1 × 10{sup 15}, 5 × 10{sup 15} and 5 × 10{sup 16} ions/cm{sup 2}. Optical characterization reveals slight differences in the absorption bands at 6.0 and 4.2 eV, attributed to F type centers and Mie scattering from Mg precipitates, respectively. DC electrical measurements using the four and two-point probe methods, between 295 and 490 K, were used to characterize the electrical conductivity of the implanted area (Meshakim and Tanabe, 2001). Measurements in this temperature range indicate that: (1) the electrical conductivity is thermally activated independently of crystallographic orientation, (2) resistance values in the implanted region decrease with fluence levels, and (3) the I–V characteristic of electrical contacts in samples with perpendicular c axis orientation is clearly ohmic, whereas contacts are blocking in samples with parallel c axis. When thin layers are sequentially removed from the implanted region by immersing the sample in a hot solution of nitric and fluorhydric acids the electrical resistance increases until reaching the values of non-implanted crystal (Jheeta et al., 2006). We conclude that the enhancement in conductivity observed in the implanted regions is related to the intrinsic defects created by the implantation rather than to the implanted Mg ions (da Silva et al., 2002; Tardío et al., 2001; Tardío et al., 2008).

  5. 238U (n,f) measurements below 30 keV

    International Nuclear Information System (INIS)

    Slovacek, R.E.; Cramer, D.S.; Bean, E.B.; Hockenbury, R.W.; Valentine, J.R.; Block, R.C.

    1975-01-01

    The 238 U (n,f) cross section has been measured from 3 eV to about 30 keV with the lead slowing down spectrometer at the RPI Linac. Four fission ionization chambers containing a total of about 0.8 gm of 238 U (4.1 ppm 235 U) were used for the measurements. The fission widths of the 6.67, 20.9, and the 36.8 eV resonances were measured as (10 +- 1), (58 +- 9), and (12 +- 2) nanoelectron-volts respectively. The fission cross section integrated over the two subthreshold groups at 720 and 1210 eV and the average fission cross section from 10 to 30 keV are in agreement with a previous time of flight measurement. The fission width at 6.67 eV is 20 times smaller than an upper limit set by the only reported measurement in this energy region; the fission widths obtained in the present investigation are consistent with the (30 +- 50) nanoelectronvolt average width previously obtained for the resonances between 37 and 327 eV in a time of flight measurement using a nuclear device. From the measured fission widths, the 238 U thermal fission cross section was determined to be 2.7 +- 0.3 μ barns. The resonance fission integral was also obtained from the data as 1.33 +- 0.15 mbarns for 238 U. (4 figures, 4 tables) (U.S.)

  6. Protease activity of Per a 10 potentiates Th2 polarization by increasing IL-23 and OX40L.

    Science.gov (United States)

    Agrawal, Komal; Kale, Sagar L; Arora, Naveen

    2015-12-01

    Proteases are implicated in exacerbation of allergic diseases. In this study, the role of proteolytic activity of Per a 10 was evaluated on Th2 polarization. Intranasal administration of Per a 10 in mice led to allergic airway inflammation as seen by higher IgE levels, cellular infiltration, IL-17A, and Th2 cytokines, whereas, inactive (Δ)Per a 10 showed attenuated response. There was an increased OX40L expression on lung and lymph node dendritic cells in Per a 10 immunized group and on Per a 10 stimulated BMDCs. Reduction in CD40 expression without any change at transcript level in lungs of Per a 10 immunized mice suggested CD40 cleavage. BMDCs pulsed with Per a 10 showed reduced CD40 expression with lower IL-12p70 secretion as compared to heat inactivated Per a 10. IL-23, TNF-α, and IL-6 levels were significantly higher in Per a 10 stimulated BMDCs supernatant. In DC-T cell coculture studies, Per a 10 pulsed BMDCs showed higher levels of IL-4 and IL-13 that were reduced on blocking of either IL-23 or OX40L. In conclusion, the data suggests a critical role of protease activity of Per a 10 in promoting Th2 polarization by increasing IL-23 secretion and OX40L expression on dendritic cells. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Intrinsic magnetic properties of L1{sub 0} FeNi obtained from meteorite NWA 6259

    Energy Technology Data Exchange (ETDEWEB)

    Poirier, Eric [MEDA Engineering and Technical Services, Southfield, Michigan 48075 (United States); Pinkerton, Frederick E., E-mail: frederick.e.pinkerton@gm.com; Kubic, Robert; Mishra, Raja K. [Chemical Sciences and Materials Systems Lab, GM R and D Center, Warren, Michigan 48090 (United States); Bordeaux, Nina; Lewis, Laura H. [Department of Chemical Engineering, Northeastern University, Boston, Massachusetts 02115 (United States); Mubarok, Arif; Goldstein, Joseph I. [Department of Mechanical and Industrial Engineering, University of Massachusetts, Amherst, Massachusetts 01003 (United States); Skomski, Ralph [Department of Physics and Astronomy, University of Nebraska, Lincoln, Nebraska 68588 (United States); Barmak, Katayun [Department of Applied Physics and Applied Mathematics, Columbia University, New York, New York 10027 (United States)

    2015-05-07

    FeNi having the tetragonal L1{sub 0} crystal structure is a promising new rare-earth-free permanent magnet material. Laboratory synthesis is challenging, however, tetragonal L1{sub 0} FeNi—the mineral “tetrataenite”—has been characterized using specimens found in nickel-iron meteorites. Most notably, the meteorite NWA 6259 recovered from Northwest Africa is 95 vol. % tetrataenite with a composition of 43 at. % Ni. Hysteresis loops were measured as a function of sample orientation on a specimen cut from NWA 6259 in order to rigorously deduce the intrinsic hard magnetic properties of its L1{sub 0} phase. Electron backscatter diffraction showed that NWA 6259 is strongly textured, containing L1{sub 0} grains oriented along any one of the three equivalent cubic directions of the parent fcc structure. The magnetic structure was modeled as a superposition of the three orthonormal uniaxial variants. By simultaneously fitting first-quadrant magnetization data for 13 different orientations of the sample with respect to the applied field direction, the intrinsic magnetic properties were estimated to be saturation magnetization 4πM{sub s} = 14.7 kG and anisotropy field H{sub a} = 14.4 kOe. The anisotropy constant K = 0.84 MJ/m{sup 3} is somewhat smaller than the value K = 1.3 MJ/m{sup 3} obtained by earlier researchers from nominally equiatomic FeNi prepared by neutron irradiation accompanied by annealing in a magnetic field, suggesting that higher Ni content (fewer Fe antisite defects) may improve the anisotropy. The fit also indicated that NWA 6259 contains one dominant variant (62% by volume), the remainder of the sample being a second variant, and the third variant being absent altogether.

  8. Interaction between Solid Nitrogen and 1-3-keV Electrons

    DEFF Research Database (Denmark)

    Schou, Jørgen; Sørensen, H.

    1978-01-01

    V. At 3 keV, the SEE coefficient is 12 times that for solid deuterium. This is attributed partly to the larger production rate for low-energy electrons in nitrogen and partly to the larger escape probability for these electrons. Moreover, measurements were made of the electron-reflection coefficient, both......Experimental studies were made of the interaction between solid nitrogen and beams of 1-2-keV electrons. The projected range for the electrons was measured by means of the mirror-substrate method (gold substrate), giving the result 9.02×1016 E1.75 molecules/cm2 with the energy given in ke...... for solid nitrogen and for the carbon substrate. For nitrogen, it varied from 0.17 el/el at 1 keV to 0.13 el/el at 3 keV, and for carbon it varied from 0.13 to 0.12. The observations are discussed and comparisons made with other theoretical and experimental results. The agreement ranges from good to fair...

  9. 5,10,15,20-Tetrakis(4-carboxyl phenyl)porphyrin–CdS nanocomposites with intrinsic peroxidase-like activity for glucose colorimetric detection

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Qingyun, E-mail: qyliu@sdust.edu.cn [School of Chemistry and Environmental Engineering, Shandong University of Science and Technology, Qingdao 266510 (China); Jia, Qingyan; Zhu, Renren; Shao, Qian; Wang, Dongmei; Cui, Peng [School of Chemistry and Environmental Engineering, Shandong University of Science and Technology, Qingdao 266510 (China); Ge, Jiechao, E-mail: jchge2010@mail.ipc.ac.cn [Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190 (China)

    2014-09-01

    Here, we describe the design of a novel mimic peroxidase, nanocomposites composed by 5,10,15,20-tetrakis(4-carboxyl phenyl)-porphyrin (H{sub 2}TCPP) and cadmium sulfide (CdS). The H{sub 2}TCPP–CdS nanocomposites can catalyze oxidation of substrate 3,3,5,5-tetramethylbenzidine (TMB) in the presence of H{sub 2}O{sub 2} and form a blue product which can be seen by the naked eye in 5 min. The mechanism of the catalytic reaction originated from the generation of hydroxyl radical (·OH), which is a powerful oxidizing agent to oxidize TMB to produce a blue product. Then, we developed a colorimetric method that is highly sensitive and selective to detect glucose, combined with glucose oxidase (GOx). The proposed method allowed the detection of H{sub 2}O{sub 2} concentration in the range of 4 × 10{sup −6}–1.4 × 10{sup −5} M and glucose in the range of 1.875 × 10{sup −5}–1 × 10{sup −4} M with detectable H{sub 2}O{sub 2} concentration as low as 4.6 × 10{sup −7} M and glucose as low as 7.02 × 10{sup −6} M, respectively. The results provided the theoretical basis of practical application in glucose detecting and peroxidase mimetic enzymes. - Graphical abstract: 5,10,15,20-tetrakis(4-carboxyl phenyl)-porphyrin (H{sub 2}TCPP)–CdS nanohybrids were demonstrated to possess intrinsic peroxidase-like activity and used for a glucose colorimetric sensor. - Highlights: • H{sub 2}TCPP–CdS nanocomposites were synthesized by a facile one step under mild condition. • H{sub 2}TCPP–CdS nanocomposites possess excellent intrinsic peroxidase-like activity. • A sensitive and selective colorimetric sensor for glucose is provided based on H{sub 2}TCPP–CdS nanocomposites. • The generation of hydroxyl radical (·OH) decomposed from H{sub 2}O{sub 2} is contributed to efficient catalytic.

  10. Nucleosynthesis confronts an unstable inert 17 keV state

    International Nuclear Information System (INIS)

    Enqvist, K.; Kainulainen, K.; Thomson, M.

    1991-01-01

    We study the cosmological consequences of an inert 17 keV state mixing with the electron neutrino. We find that the nucleosynthesis upper bound on the primordial helium abundance prohibits the existence of such a state, unless its lifetime falls into the range 6x10 -4 s vac -2 s. In this range the decay occurs after the chemical decoupling of the electron neutrinos and before the beginning of the nucleosynthesis, with the result that the predicted helium abundance can be lower than what it would be in the standard scenario. (orig.)

  11. Atomic mixing effects on high fluence Ge implantation into Si at 40 keV

    International Nuclear Information System (INIS)

    Gras-Marti, A.; Jimenez-Rodriguez, J.J.; Peon-Fernandez, J.; Rodriguez-Vidal, M.; Tognetti, N.P.; Carter, G.; Nobes, M.J.; Armour, D.G.

    1982-01-01

    Ion implanted profiles of 40 keV Ge + into Si at fluences ranging from approx. equal to 10 15 ions/cm 2 up to saturation have been measured using the RBS technique. The profiles compare well with the predictions of an analytical model encompasing sputter erosion plus atomic relocation. (orig.)

  12. Measurement of deuteron induced gamma-ray emission differential cross sections on {sup nat}Cl from 1.0 to 2.0 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Jokar, A., E-mail: arezajokar@gmail.com; Kakuee, O.; Lamehi-Rachti, M.

    2016-06-15

    In this research work, measured differential cross sections for gamma-ray emission from the nuclear reactions {sup 35}Cl(d,pγ{sub 1-0}){sup 36}Cl (E{sub γ} = 788 keV), {sup 35}Cl(d,pγ{sub 2-0}){sup 36}Cl (Eγ = 1165 keV), {sup 37}Cl(d,pγ{sub 1-0}){sup 38}Cl (E{sub γ} = 671 keV) and {sup 37}Cl(d,pγ{sub 2-0}){sup 38}Cl (E{sub γ} = 755 keV) are presented. For these measurements a thin natural BaCl{sub 2} target evaporated onto a 50 μm-thick Mo foil was used. The gamma-rays and backscattered deuterons were detected simultaneously. An HPGe detector placed at an angle of 90° with respect to the beam direction was employed to collect gamma-rays while an ion implanted Si detector placed at a scattering angle of 165° was used to detect backscattered deuterons. The validity of the obtained differential cross sections was verified through a thick target benchmarking experiment. The overall systematic uncertainty of cross section values was estimated to be ±10%.

  13. The direct l-type resonance spectrum of CF3CCH in the vibrational state ν 10 = 2

    International Nuclear Information System (INIS)

    Woetzel, Ulf; Maeder, Heinrich; Harder, Hauke; Pracna, Petr; Sarka, Kamil

    2005-01-01

    The direct l-type resonance spectrum of CF 3 CCH in the vibrational state ν 10 = 2 has been measured by means of waveguide microwave Fourier transform spectroscopy in the range 8-26 GHz. Two types of direct l-type resonance transitions induced by the (Δk = ±2, Δl = ±2) interaction could be observed: 262 transitions following the ΔJ = 0, Δk = Δl = 2 selection rule covering values of J = 17-64 and G vertical bar k - l vertical bar from 2 to 15, and 75 transitions following the ΔJ = 0, Δk = Δl = 4 selection rule covering values of J = 44-70 and G up to 3. The strong (2, 2) resonance furthermore allowed the observation of A 1 -A 2 splittings of the k = l = ±2 states from J = 63-70. The transitions with G = 3 showed splittings due to the (4, -2) and (0, 6) interactions. The corresponding energy level systems and part of the Hamiltonian matrix are discussed. Strong perturbations due to Δ(k - l) = 3 interactions coupling the states k = ±1, l = ±2 and k = ±4, l ±2 made possible the observation of perturbation-allowed transitions with selection rule k = ±1, l2 ↔ k = 0, l = ±2. Additionally, the J = 2-1 and 3-2 rotational transitions have been measured. A multiple fitting analysis has been performed in which the experimental data have been fitted using five reduced forms of the effective Hamiltonian as proposed by Sarka and Harder [J. Mol. Spectrosc. 197 (1999) 254]. Parameters up to sixth order have been determined including the axial rotational constant A for both values of vertical bar l vertical bar and the unitary equivalence of the determined parameter sets has been demonstrated

  14. Origin of 30 approximately 100 keV protons observed in the upstream region of the earth's bow shock

    International Nuclear Information System (INIS)

    Terasawa, T.

    1979-01-01

    A Fermi-type acceleration model is constructed to explain the origin of energetic protons (30 approximately 100 keV) which have been observed upstream of the bow shock. It is shown that the suprathermal protons (with energy of several keV) can be accelerated up to several tens of keV through the Fermi-type process in which the reflection at the shock front and the scattering in the upstream region are coupled. The efficiency of the scattering process is estimated by using the results of Barnes' quasilinear treatment of the wave excitation. The resultant energy spectrum and flux intensity (10 3 approximately 10 4 protons/(cm 2 s ster keV) in 32 approximately 45.3 keV) are consistent with the observation, and the softening of the energy spectrum observed in the dawn region can be explained by the decrease in the efficiency of the acceleration process in the dawn region due to the curvature of the bow shock and the reduction of shock strength. The spatial distribution of the flux predicted by the model is also consistent with the observation. In view of these consistencies of the Fermi-type acceleration process is suggested as a possible candidate mechanism to explain the upstream protons although it is not intended to exclude other possibilities. (author)

  15. Test facility for the development of 150-keV, multi-megawatt neutral beam systems

    International Nuclear Information System (INIS)

    Haughian, W.; Baker, W.R.; Biagi, L.A.; Hopkins, D.B.

    1975-11-01

    The next generation of CTR experiments, such as the Tokamak Fusion Test Reactor (TFTR), will require neutral-beam injection systems that produce multi-megawatt, 120-keV deuterium-beam pulses of 0.5-second duration. Since present injection systems are operating in the 10- to 40-keV range, an intensive development effort is in progress to meet a 150-keV requirement. The vacuum system and power supplies that make up a test facility to be used in the development of these injectors are described

  16. NuSTAR Observations of the Compton-thick Active Galactic Nucleus and Ultraluminous X-Ray Source Candidate in NGC 5643

    Science.gov (United States)

    Annuar, A.; Gandhi, P.; Alexander, D. M.; Lansbury, G. B.; Arévalo, P.; Ballantyne, D. R.; Baloković, M.; Bauer, F. E.; Boggs, S. E.; Brandt, W. N.; Brightman, M.; Christensen, F. E.; Craig, W. W.; Del Moro, A.; Hailey, C. J.; Harrison, F. A.; Hickox, R. C.; Matt, G.; Puccetti, S.; Ricci, C.; Rigby, J. R.; Stern, D.; Walton, D. J.; Zappacosta, L.; Zhang, W.

    2015-12-01

    We present two Nuclear Spectroscopic Telescope Array (NuSTAR) observations of the local Seyfert 2 active galactic nucleus (AGN) and an ultraluminous X-ray source (ULX) candidate in NGC 5643. Together with archival data from Chandra, XMM-Newton, and Swift-BAT, we perform a high-quality broadband spectral analysis of the AGN over two decades in energy (˜0.5-100 keV). Previous X-ray observations suggested that the AGN is obscured by a Compton-thick (CT) column of obscuring gas along our line of sight. However, the lack of high-quality ≳10 keV observations, together with the presence of a nearby X-ray luminous source, NGC 5643 X-1, have left significant uncertainties in the characterization of the nuclear spectrum. NuSTAR now enables the AGN and NGC 5643 X-1 to be separately resolved above 10 keV for the first time and allows a direct measurement of the absorbing column density toward the nucleus. The new data show that the nucleus is indeed obscured by a CT column of NH ≳ 5 × 1024 cm-2. The range of 2-10 keV absorption-corrected luminosity inferred from the best-fitting models is L2-10,int = (0.8-1.7) × 1042 erg s-1, consistent with that predicted from multiwavelength intrinsic luminosity indicators. In addition, we also study the NuSTAR data for NGC 5643 X-1 and show that it exhibits evidence of a spectral cutoff at energy E ˜ 10 keV, similar to that seen in other ULXs observed by NuSTAR. Along with the evidence for significant X-ray luminosity variations in the 3-8 keV band from 2003 to 2014, our results further strengthen the ULX classification of NGC 5643 X-1.

  17. NUCLEAR X-RAY PROPERTIES OF THE PECULIAR RADIO-LOUD HIDDEN AGN 4C+29.30

    International Nuclear Information System (INIS)

    Sobolewska, M. A.; Siemiginowska, Aneta; Migliori, G.; Evans, D.; Stawarz, Ł.; Jamrozy, M.; Cheung, C. C.

    2012-01-01

    We present results from a study of nuclear emission from a nearby radio galaxy, 4C+29.30, over a broad 0.5-200 keV X-ray band. This study used new XMM-Newton (∼17 ks) and Chandra (∼300 ks) data, and archival Swift/BAT data from the 58 month catalog. The hard (>2 keV) X-ray spectrum of 4C+29.30 can be decomposed into an intrinsic hard power law (Γ ∼ 1.56) modified by a cold absorber with an intrinsic column density N H,z ∼ 5 × 10 23 cm –2 , and its reflection (|Ω/2π| ∼ 0.3) from a neutral matter including a narrow iron Kα emission line at a rest-frame energy ∼6.4 keV. The reflected component is less absorbed than the intrinsic one with an upper limit on the absorbing column of N refl H,z 22 cm –2 . The X-ray spectrum varied between the XMM-Newton and Chandra observations. We show that a scenario invoking variations of the normalization of the power law is favored over a model with variable intrinsic column density. X-rays in the 0.5-2 keV band are dominated by diffuse emission modeled with a thermal bremsstrahlung component with temperature ∼0.7 keV, and contain only a marginal contribution from the scattered power-law component. We hypothesize that 4C+29.30 belongs to a class of 'hidden' active galactic nuclei containing a geometrically thick torus. However, unlike the majority of hidden AGNs, 4C+29.30 is radio-loud. Correlations between the scattering fraction and Eddington luminosity ratio, and between black hole mass and stellar velocity dispersion, imply that 4C+29.30 hosts a black hole with ∼10 8 M ☉ mass.

  18. Test and Analysis of Tube Component of Electron Beam Machine (EBM) 350 keV/10 m A

    International Nuclear Information System (INIS)

    Darsono; Suprapto; Rany Saptaaji

    2003-01-01

    Tube component is the one of the local component that is designed and constructed using local materials in the Center of Advanced Technology Research and Development, and used mainly for vacuum chamber of EBM vacuum system. Gas load, product gases from out gassing process, permeation, evaporation and leakage, are factors that can affect the vacuum level of the vacuum chamber. By baking out the vacuum chamber, the releasing process from inside and wall surface will be faster, so that the out gassing and permeation rate will increase. By applying baked out process the tube having better vacuum performance were obtained. From the calculation results for the vacuum level chamber having volume of 9,859 liter and surface area of 4004,45 cm 2 , without baking out the out gassing rate (Q D ) was 4,644 x 10 -6 Torr liter/sec., permeation (Q P ) was 4,923 x 10 -6 Torr liter/sec., leakage (Q L ) was 1,691 x 10 -9 Torr liter/sec, gas load (Q G ) was 9,568 x 10 -6 Torr liter/sec. By baking out at 104,3 o C we obtained (Q D ) 2,276 x 10 -5 Torr liter/sec, (Q P ) 1,831 x 10 -5 Torr liter/sec, (Q L ) 3,161 x 10 -9 Torr liter/sec, and (Q G ) 4,108 x 10 -5 Torr liter/sec. The experimental results indicated that the final vacuum level which can be obtained the tube component without baking out was 3.375 x 10 -6 Torr in 5.33 hours, and with baking out at 104,3 o C the vacuum level was 2,25 x 10 -6 Torr in 4,25 hours. Whereas the experimental results of vacuum components in EBM system to be obtained the vacuum were 3,1 x 10 -6 mbar (2,33.10 -6 Torr). Those result indicated that the tube components fulfill the requirement to be used for the vacuum chamber component in the vacuum system of EBM. (author)

  19. The NuSTAR  Extragalactic Surveys: X-Ray Spectroscopic Analysis of the Bright Hard-band Selected Sample

    Science.gov (United States)

    Zappacosta, L.; Comastri, A.; Civano, F.; Puccetti, S.; Fiore, F.; Aird, J.; Del Moro, A.; Lansbury, G. B.; Lanzuisi, G.; Goulding, A.; Mullaney, J. R.; Stern, D.; Ajello, M.; Alexander, D. M.; Ballantyne, D. R.; Bauer, F. E.; Brandt, W. N.; Chen, C.-T. J.; Farrah, D.; Harrison, F. A.; Gandhi, P.; Lanz, L.; Masini, A.; Marchesi, S.; Ricci, C.; Treister, E.

    2018-02-01

    We discuss the spectral analysis of a sample of 63 active galactic nuclei (AGN) detected above a limiting flux of S(8{--}24 {keV})=7× {10}-14 {erg} {{{s}}}-1 {{cm}}-2 in the multi-tiered NuSTAR extragalactic survey program. The sources span a redshift range z=0{--}2.1 (median =0.58). The spectral analysis is performed over the broad 0.5–24 keV energy range, combining NuSTAR with Chandra and/or XMM-Newton data and employing empirical and physically motivated models. This constitutes the largest sample of AGN selected at > 10 {keV} to be homogeneously spectrally analyzed at these flux levels. We study the distribution of spectral parameters such as photon index, column density ({N}{{H}}), reflection parameter ({\\boldsymbol{R}}), and 10–40 keV luminosity ({L}{{X}}). Heavily obscured ({log}[{N}{{H}}/{{cm}}-2]≥slant 23) and Compton-thick (CT; {log}[{N}{{H}}/{{cm}}-2]≥slant 24) AGN constitute ∼25% (15–17 sources) and ∼2–3% (1–2 sources) of the sample, respectively. The observed {N}{{H}} distribution agrees fairly well with predictions of cosmic X-ray background population-synthesis models (CXBPSM). We estimate the intrinsic fraction of AGN as a function of {N}{{H}}, accounting for the bias against obscured AGN in a flux-selected sample. The fraction of CT AGN relative to {log}[{N}{{H}}/{{cm}}-2]=20{--}24 AGN is poorly constrained, formally in the range 2–56% (90% upper limit of 66%). We derived a fraction (f abs) of obscured AGN ({log}[{N}{{H}}/{{cm}}-2]=22{--}24) as a function of {L}{{X}} in agreement with CXBPSM and previous zvalues.

  20. Total L-shell X-ray production cross sections by 400-700 keV proton impact for elements with 34≤Z≤53

    International Nuclear Information System (INIS)

    Miranda, J.; Ledesma, R.; Lucio, O.G. de

    2001-01-01

    Total L-shell X-ray production cross sections induced by protons with energies between 400 and 700 keV were measured for elements with atomic number Z between 34 and 53. The ECPSSR theory describes appropriately the results. This model modifies the plane wave born approximation by considering projectile energy loss (E), Coulomb deflection of the incoming ion (C), polarization and change in electron binding energies through a perturbed stationary states method (PSS) and relativistic values of target electron mass (R). A comparison is given with previously published data for proton energies below 1 MeV and 26 ≤ Z ≤ 53, based on a scaling obtained from a reduced velocity parameter ξ L R . The results show that the scaling for these atomic numbers and energy ranges is adequate and a semi-empirical expression to calculate those cross sections is proposed

  1. X-ray attenuation coefficient measurements for photon energies 4.508-13.375 keV in Cu, Cr and their compounds and the validity of the mixture rule

    International Nuclear Information System (INIS)

    Turgut, Ue.; Simsek, Oe.; Bueyuekkasap, E.; Ertugrul, M.

    2004-01-01

    To investigate the validity of the mixture rule which is used to compute the mass attenuation coefficients in compounds, the total mass attenuation coefficients for Cu, Cr elements and Cu 2 O, CuC 2 O 4 , CuCl 2 ·2H 2 O, Cu(C 2 H 3 O 2 ) 2 ·H 2 O, Cr 2 O 3 , Cr(NO 3 ) 3 , Cr 2 (SO 4 ) 3 ·H 2 O, Cr 3 (CH 3 CO 7 )(OH) 2 compounds were measured at photon energies between 4.508 and 13.375 keV by using the secondary excitation method. Ti, Mn, Fe, Ni, Zn, Ge, As, Rb elements were used as secondary exciters. 59.5 keV gamma rays emitted from an 241 Am annular source were used to excite the secondary exciters and Kα (K-L 3 , L 2 ) rays emitted from the secondary exciter were counted by a Si(Li) detector with a resolution of 160 eV at 5.9 keV. Our measurements indicate that the mixture rule is not a suitable method for the computation of mass attenuation coefficients of compounds especially at an energy that is near the absorption edge. Obtained values were compared with theoretical values

  2. Spatial distribution of upstream magnetospheric ≥50 keV ions

    Directory of Open Access Journals (Sweden)

    G. C. Anagnostopoulos

    2000-01-01

    Full Text Available We present for the first time a statistical study of \\geq50 keV ion events of a magnetospheric origin upstream from Earth's bow shock. The statistical analysis of the 50-220 keV ion events observed by the IMP-8 spacecraft shows: (1 a dawn-dusk asymmetry in ion distributions, with most events and lower intensities upstream from the quasi-parallel pre-dawn side (4 LT-6 LT of the bow shock, (2 highest ion fluxes upstream from the nose/dusk side of the bow shock under an almost radial interplanetary magnetic field (IMF configuration, and (3 a positive correlation of the ion intensities with the solar wind speed and the index of geomagnetic index Kp, with an average solar wind speed as high as 620 km s-1 and values of the index Kp > 2. The statistical results are consistent with (1 preferential leakage of ~50 keV magnetospheric ions from the dusk magnetopause, (2 nearly scatter free motion of ~50 keV ions within the magnetosheath, and (3 final escape of magnetospheric ions from the quasi-parallel dawn side of the bow shock. An additional statistical analysis of higher energy (290-500 keV upstream ion events also shows a dawn-dusk asymmetry in the occurrence frequency of these events, with the occurrence frequency ranging between ~16%-~34% in the upstream region.Key words. Interplanetary physics (energetic particles; planetary bow shocks

  3. Spatial distribution of upstream magnetospheric ≥50 keV ions

    Directory of Open Access Journals (Sweden)

    G. Kaliabetsos

    Full Text Available We present for the first time a statistical study of geq50 keV ion events of a magnetospheric origin upstream from Earth's bow shock. The statistical analysis of the 50-220 keV ion events observed by the IMP-8 spacecraft shows: (1 a dawn-dusk asymmetry in ion distributions, with most events and lower intensities upstream from the quasi-parallel pre-dawn side (4 LT-6 LT of the bow shock, (2 highest ion fluxes upstream from the nose/dusk side of the bow shock under an almost radial interplanetary magnetic field (IMF configuration, and (3 a positive correlation of the ion intensities with the solar wind speed and the index of geomagnetic index Kp, with an average solar wind speed as high as 620 km s-1 and values of the index Kp > 2. The statistical results are consistent with (1 preferential leakage of ~50 keV magnetospheric ions from the dusk magnetopause, (2 nearly scatter free motion of ~50 keV ions within the magnetosheath, and (3 final escape of magnetospheric ions from the quasi-parallel dawn side of the bow shock. An additional statistical analysis of higher energy (290-500 keV upstream ion events also shows a dawn-dusk asymmetry in the occurrence frequency of these events, with the occurrence frequency ranging between ~16%-~34% in the upstream region.Key words. Interplanetary physics (energetic particles; planetary bow shocks

  4. Linear attenuation coefficients of tissues from 1 keV to 150 keV

    Science.gov (United States)

    Böke, Aysun

    2014-09-01

    The linear attenuation coefficients and three interaction processes have been computed for liver, kidney, muscle, fat and for a range of x-ray energies from 1 keV to 150 keV. Molecular photoelectric absorption cross sections were calculated from atomic cross section data. Total coherent (Rayleigh) and incoherent (Compton) scattering cross sections were obtained by numerical integration over combinations of F2m(x) with the Thomson formula and Sm(x) with the Klein-Nishina formula, respectively. For the coherent (Rayleigh) scattering cross section calculations, molecular form factors were obtained from recent experimental data in the literature for values of xelements involved in tissue composition is 5 for liver, 47 for kidney, 44 for muscle and 3 for fat. The results are compared with previously published experimental and theoretical linear attenuation coefficients. In general, good agreement is obtained. The molecular form factors and scattering functions and cross sections are incorporated into a Monte Carlo program. The energy distributions of x-ray photons scattered from tissues have been simulated and the results are presented.

  5. Li (i = 1-3) subshell X-ray production cross sections and fluorescence yields for some elements with 56 ≤ Z ≤ 68 at 22.6 keV

    International Nuclear Information System (INIS)

    Chauhan, Yogeshwar; Tiwari, M.K.; Puri, Sanjiv

    2008-01-01

    The L k (k = l, α, β 1,4 , β 3,6 , β 2,15,9,10,7 , γ 1,5 and γ 2,3,4 ) X-ray production (XRP) cross sections have been measured for six elements with 56 ≤ Z ≤ 68 at 22.6 keV incident photon energy using the EDXRF spectrometer. The incident photon intensity, detector efficiency and geometrical factors have been determined from the K X-ray yields emitted from elemental targets with 22 ≤ Z ≤ 42 in the same geometrical setup and from knowledge of the K XRP cross sections. The L 1 and L 2 subshell fluorescence yields have been deduced from the present measured L k XRP cross sections using the relativistic Hartree-Fock-Slater (HFS) model based photoionization cross sections. The present deduced ω 1 (exp) values have been found to be, on an average, higher by 15% and 20% than those based on the Dirac-Hartree-Slater (DHS) model and the semi-empirical values compiled by Krause, respectively, for elements with 60 ≤ Z ≤ 68

  6. Measurement of L X-ray fluorescence cross-sections for elements with 45 ≤ Z ≤ 50 using synchrotron radiation at 8 keV

    International Nuclear Information System (INIS)

    Bonzi, Edgardo V.; Badiger, Nagappa M.; Grad, Gabriela B.; Barrea, Raul A.; Figueroa, Rodolfo G.

    2011-01-01

    The L shell fluorescence cross-sections of the elements in range 45 ≤ Z ≤ 50 have been determined at 8 keV using Synchrotron radiation. The individual L X-ray photons, Ll, Lα, Lβ I , Lβ II , Lγ I and Lγ II produced in the target were measured with high resolution Si(Li) detector. The experimental set-up provided a low background by using linearly polarized monoenergetic photon beam, improving the signal-to-noise ratio. The experimental cross-sections obtained in this work were compared with available experimental data from Scofield Krause and Scofield and Puri et al. . These experimental values closely agree with the theoretical values calculated using Scofield and Krause data, except for the case of Lγ, where values measured of this work are slighter higher.

  7. Vibrational and cascade dissociation of H{sub 2}{sup +} ions by collision with gas molecules; Dissociation vibrationnelle et dissociation en cascade d'ions H{sub 2}{sup +} par collisions avec les molecules d'un gaz

    Energy Technology Data Exchange (ETDEWEB)

    Verveer, P [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1966-07-01

    Protons produced by collisional dissociation of H{sub 2}{sup +} ions have an energy spectrum with a narrow central peak. For a part the protons in this peak are produced by vibrational dissociation and for another part by a cascade of two collisions. For H{sub 2}{sup +} ions of 50 to 150 keV the cross section for vibrational dissociation is about 4.1 10{sup -19} cm{sup 2}/molecule in hydrogen and 1.1 10{sup -18} cm{sup 2}/molecule in argon. (author) [French] Les protons resultant de la dissociation par collisions d'ions H{sub 2}{sup +} dans un gaz ont un spectre d'energie qui presente un pic central tres etroit. Les protons dans ce pic proviennent, pour une part de la dissociation vibrationnelle et pour l'autre part d'une suite de deux collisions. Dans le domaine d'energie des ions H{sub 2}{sup +} de 50 a 150 keV la section efficace de dissociation vibrationnel vaut 4.1 10{sup -19} cm{sup 2}/molecule pour l'hydrogene et 1,1 10{sup -18} cm{sup 2}/molecule pour l'argon.

  8. Sputtering of solid nitrogen by keV helium ions

    DEFF Research Database (Denmark)

    Ellegaard, O.; Schou, Jørgen; Sørensen, H.

    1993-01-01

    Solid nitrogen has become a standard material among the frozen molecular gases for electronic sputtering. We have combined measurements of sputtering yields and energy spectra from nitrogen bombarded by 4-10 keV helium ions. The data show that the erosion is electronic rather than knockon...

  9. An assay for serum vitamin-B12 and for intrinsic factor antibody type I by means of hog intrinsic factor

    International Nuclear Information System (INIS)

    Hudak, J.; Berger, Z.; Varga, L.

    1980-01-01

    A new radioassay method was elaborated for the determination of the plasma level of vitamin B 12 and of the intrinsic factor antibody type I. The assay applies vitamin-B 12 labelled with 58 Co, but replaces human intrinsic factor by hog intrinsic factor. 124 cases were investigated by both the original and this modified method, and the results were in very good agreement. (L.E.)

  10. NuSTAR Reveals Extreme Absorption in z <0.5 Type 2 Quasars

    DEFF Research Database (Denmark)

    Lansbury, G. B.; Gandhi, P.; Alexander, D. M.

    2015-01-01

    The intrinsic column density (N-H) distribution of quasars is poorly known. At the high obscuration end of the quasar population and for redshifts z <1, the X-ray spectra can only be reliably characterized using broad-band measurements that extend to energies above 10 keV. Using the hard X-ray ob...

  11. Crystal growth nucleation and Fermi energy equalization of intrinsic spherical nuclei in glass-forming melts

    Directory of Open Access Journals (Sweden)

    Robert F Tournier

    2009-01-01

    Full Text Available The energy saving resulting from the equalization of Fermi energies of a crystal and its melt is added to the Gibbs free-energy change ΔG2ls associated with a crystal formation in glass-forming melts. This negative contribution being a fraction ε ls(T of the fusion heat is created by the electrostatic potential energy −U0 resulting from the electron transfer from the crystal to the melt and is maximum at the melting temperature Tm in agreement with a thermodynamics constraint. The homogeneous nucleation critical temperature T2, the nucleation critical barrier ΔG2ls*/kBT and the critical radius R*2ls are determined as functions of εls(T. In bulk metallic glass forming melts, εls(T and T2 only depend on the free-volume disappearance temperature T0l, and εls(Tm is larger than 1 (T0l>Tm/3; in conventional undercooled melts εls(Tm is smaller than 1 (T0l>Tm/3. Unmelted intrinsic crystals act as growth nuclei reducing ΔG2ls*/kBT and the nucleation time. The temperature-time transformation diagrams of Mg65Y10 Cu25, Zr41.2Ti13.8 Cu12.5Ni10Be22.5, Pd43Cu27 Ni10P20, Fe83B17 and Ni melts are predicted using classic nucleation models including time lags in transient nucleation, by varying the intrinsic nucleus contribution to the reduction of ΔG2ls*/kBT. The energy-saving coefficient ε nm(T of an unmelted crystal of radius Rnm is reduced when Rnm LtR*2ls; εnm is quantified and corresponds to the first energy level of one s-electron moving in vacuum in the same spherical attractive potential −U0 despite the fact that the charge screening is built by many-body effects.

  12. 10 CFR 63.302 - Definitions for Subpart L.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Definitions for Subpart L. 63.302 Section 63.302 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) DISPOSAL OF HIGH-LEVEL RADIOACTIVE WASTES IN A GEOLOGIC... Definitions for Subpart L. All definitions in subpart K of this part, and the following: Accessible...

  13. Radiation-induced effects in MgO single crystal by 200 keV and 1 MeV Ni ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Ryohei; Nakai, Yoshihiro; Hamaguchi, Dai [Kyoto Inst. of Tech. (Japan); and others

    1997-03-01

    MgO(100) single crystals were implanted with 1.0 MeV and 200 keV Ni ions between 10{sup 15} and 10{sup 17} ions/cm{sup 2} at room temperature. Before and after thermal annealing the radiation damage and the lattice location of implanted Ni ions were analyzed by using Rutherford backscattering spectrometry with channeling and optical absorption measurements. For 1.0 MeV Ni ions, the disorder of Mg atoms increased slowly with ion dose near surface region, while it increased sharply and saturated with ion dose from 2x10{sup 16} ions/cm{sup 2} near ion range. The radiation damage was recovered and implanted Ni ions diffused to the whole of crystal and occupied substitutional positions after 1400degC annealing. For 200 keV Ni ions, the disorder of Mg atoms increased with dose near ion range and had a maximum at about 5x10{sup 16} ions/cm{sup 2}. This tendency agrees with the behavior of color centers obtained from optical measurements. For thermal annealing the radiation damage did not change during 500degC annealing, but the aggregate centers appeared after 300degC annealing. (author)

  14. Determination of the absolute K through O conversion coefficients of the 80-keV M4 transition in /sup 193/Ir/sup m/

    International Nuclear Information System (INIS)

    Lindner, M.; Gunnink, R.; Nagle, R.J.

    1987-01-01

    We produced carrier-free, nearly isotopically pure /sup 193/Ir/sup m/ from thermal-neutron irradiation of /sup 192/Os. From studies of the conversion-electron spectrum, the photon spectrum, and the absolute counting rates, we determined the absolute K, L1, L2, L3, M1, M3, M5, N, and O+P conversion coefficients for the first time. With possibly one exception, these values agree closely with theoretical calculations. The value for the energy of the unconverted gamma ray was found to be 80.22 +- 0.02 keV. The half-life for /sup 193/Ir/sup m/ determined by absolute electron counting in a proportional counter of 100% counting efficiency (4πβ) was found to be 10.53 +- 0.04 d. We have determined the L 1 subshell fluorescence yield, ω 1 , to be 0.120 +- 0.003 for iridium. Based upon our measurements of initial and final L subshell vacancies together with a best-fit literature value for ω 2 , we have found a plausible value for the Coster-Kronig coefficient f/sub 12/ to be 0.091 +- 0.011

  15. Half-Life Measurements in {sup 134}l

    Energy Technology Data Exchange (ETDEWEB)

    Berg, V; Hoeglund, Aa

    1970-07-01

    Properties of levels in I following the decay of {sup 13T}e have been investigated using a Ge(Li) detector and a double lens coincidence spectrometer. 4 new transitions were found. Half-lives of the lowest excited levels were measured with the following results: T{sub 1/2} (79.5 keV) = 1.62 {+-} 10 ns; T{sub 1/2} (181.1 keV) < 100 ps; T{sub 1/2} (210.8 keV) < 150 ps.

  16. Efficient scattering of electrons below few keV by Time Domain Structures around injection fronts

    Science.gov (United States)

    Vasko, I.; Agapitov, O. V.; Mozer, F.; Artemyev, A.; Krasnoselskikh, V.

    2016-12-01

    Van Allen Probes observations show an abundance of non-linear large-amplitude electrostatic spikes around injection fronts in the outer radiation belt. These spikes referred to as Time Domain Structures (TDS) include electron holes, double layers and more complicated solitary waves. The electron scattering driven by TDS may not be evaluated via the standard quasi-linear theory, since TDS are in principle non-linear plasma modes. In this paper we analyze the scattering of electrons by three-dimensional TDS (with non-negligible perpendicular electric field) around injection fronts. We derive the analytical formulas describing the local scattering by single TDS and show that the most efficiently scattered electrons are those in the first cyclotron resonance (electrons crossing TDS on a time scale comparable with their gyroperiod). The analytical formulas are verified via the test-particle simulation. We compute the bounce-averaged diffusion coefficients and demonstrate their dependence on the TDS spatial distribution, individual TDS parameters and L shell. We show that TDS are able to provide the pitch-angle scattering of <5 keV electrons at rate 10-2-10-4 s-1 and, thus, can be responsible for driving loss of electrons out of injections fronts on a time scale from few minutes to few hours. TDS can be, thus, responsible for driving diffuse aurora precipitations conjugated to injection fronts. We show that the pitch-angle scattering rates driven by TDS are comparable with those due to chorus waves and exceed those due to electron cyclotron harmonics. For injections fronts with no significant wave activity in the frequency range corresponding to chorus waves, TDS can be even dominant mechanism for losses of below few keV electrons.

  17. A cryogenic electrostatic trap for long-time storage of keV ion beams.

    Science.gov (United States)

    Lange, M; Froese, M; Menk, S; Varju, J; Bastert, R; Blaum, K; López-Urrutia, J R Crespo; Fellenberger, F; Grieser, M; von Hahn, R; Heber, O; Kühnel, K-U; Laux, F; Orlov, D A; Rappaport, M L; Repnow, R; Schröter, C D; Schwalm, D; Shornikov, A; Sieber, T; Toker, Y; Ullrich, J; Wolf, A; Zajfman, D

    2010-05-01

    We report on the realization and operation of a fast ion beam trap of the linear electrostatic type employing liquid helium cooling to reach extremely low blackbody radiation temperature and residual gas density and, hence, long storage times of more than 5 min which are unprecedented for keV ion beams. Inside a beam pipe that can be cooled to temperatures <15 K, with 1.8 K reached in some locations, an ion beam pulse can be stored at kinetic energies of 2-20 keV between two electrostatic mirrors. Along with an overview of the cryogenic trap design, we present a measurement of the residual gas density inside the trap resulting in only 2 x 10(3) cm(-3), which for a room temperature environment corresponds to a pressure in the 10(-14) mbar range. The device, called the cryogenic trap for fast ion beams, is now being used to investigate molecules and clusters at low temperatures, but has also served as a design prototype for the cryogenic heavy-ion storage ring currently under construction at the Max-Planck Institute for Nuclear Physics.

  18. 10 CFR 63.303 - Implementation of Subpart L.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Implementation of Subpart L. 63.303 Section 63.303 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) DISPOSAL OF HIGH-LEVEL RADIOACTIVE WASTES IN A GEOLOGIC... Implementation of Subpart L. (a) Compliance is based upon the arithmetic mean of the projected doses from DOE's...

  19. Compton polarimetry detection of small circularly and linearly polarized impurities in Mössbauer 8.4 keV (3/2-1/2) M1 γ-transition of {sup 169}Tm

    Energy Technology Data Exchange (ETDEWEB)

    Tsinoev, V.; Cherepanov, V.; Shuvalov, V.; Balysh, A.; Gabbasov, R., E-mail: graul@list.ru [National Research Centre “Kurchatov Institute” (Russian Federation)

    2016-12-15

    The arrangement of an experiment to detect the P−odd and P, T−odd polarized part of the Mössbauer ({sup +}3/2– {sup +}1/2) gamma transition of a deformed {sup 169}Tm nucleus with an energy of 8.4 keV by Compton polarimetry is discussed. Tm {sub 2}O{sub 3} single crystal with a quadrupolarly split Mössbauer spectrum is proposed as a resonance polarizer. A Be-scatterer-based Compton polarimeter and a synchronously detecting system will be used to measure the P-odd circular polarization P{sub C}and P, T-odd linear polarization P{sub L}.The expected accuracy of measuring the relative magnitude of the P, T-odd contribution is about 1% of the magnitude of usual weak nucleon–nucleon interaction.

  20. Searches for 3.5 keV Absorption Features in Cluster AGN Spectra

    Science.gov (United States)

    Conlon, Joseph P.

    2018-06-01

    We investigate possible evidence for a spectral dip around 3.5 keV in central cluster AGNs, motivated by previous results for archival Chandra observations of the Perseus cluster and the general interest in novel spectral features around 3.5 keV that may arise from dark matter physics. We use two deep Chandra observations of the Perseus and Virgo clusters that have recently been made public. In both cases, mild improvements in the fit (Δχ2 = 4.2 and Δχ2 = 2.5) are found by including such a dip at 3.5 keV into the spectrum. A comparable result (Δχ2 = 6.5) is found re-analysing archival on-axis Chandra ACIS-S observations of the centre of the Perseus cluster.

  1. Irradiation effects on secondary structure of protein induced by keV ions

    International Nuclear Information System (INIS)

    Cui, F.Z.; Lin, Y.B.; Zhang, D.M.; Tian, M.B.

    2001-01-01

    Protein secondary structure changes by low-energy ion irradiation are reported for the first time. The selected system is 30 keV N + irradiation on bovine serum albumin (BSA). After irradiation at increasing fluences from 1.0x10 15 to 2.5x10 16 ion/cm 2 , Fourier transform infrared spectra analysis was conducted. It was found that the secondary structures of BSA molecules were very sensitive to ion irradiation. Secondary conformations showed different trends of change during irradiation. With the increase of ion fluence from 0 to 2.5x10 16 ion/cm 2 , the fraction of α-helix and β-turns decreased from 17 to 12%, and from 40 to 31%, respectively, while that of random coil and β-sheet structure increased from 18 to 27%, and from 25 to 30%, respectively. Possible explanations for the secondary conformational changes of protein are proposed. (author)

  2. Measurement of photon mass attenuation coefficients of plutonium from 60 to 2615 keV

    International Nuclear Information System (INIS)

    Rettschlag, M.; Berndt, R.; Mortreau, P.

    2007-01-01

    Measurements have been made to determine plutonium photon mass attenuation coefficients by using a collimated-beam transmission method in the energy range from 60 to 2615 keV. These experimental results were compared with previous experimental and theoretical data. Good agreements are observed in the 240-800 keV energy range, whereas differences up to maximum 10% are observed out of these limits

  3. EXAFS analysis of the L3 edge of Ce in CeO2: effects of multielectron excitations and final-state mixed valence

    International Nuclear Information System (INIS)

    Fonda, E.; Andreatta, D.; Colavita, P.E.; Vlaic, G.

    1999-01-01

    Cerium oxide (IV) (CeO 2 ) is extensively employed in heterogeneous catalysis, particularly as a promoter of noble metal action in three-way catalysts. For this reason there is a great scientific and economical interest in the development of any possible chemical or structural analysis technique that could provide information on these systems. EXAFS spectroscopy has revealed itself as a powerful technique for structural characterization of such catalysts. Unfortunately, good quality K-edge spectra of cerium are not yet easily obtainable because of the high photon energy required (>40 keV). On the other hand, at lower energies it is easy to collect very good spectra of the L 3 edge (5.5 keV), but L 3 -edge spectra of cerium (IV) are characterized by the presence of two undesired additional phenomena that interfere with EXAFS analysis: final-state mixed-valence behaviour and intense multi-electron excitations. Here, a comparative analysis of the K, L 3 , L 2 and L 1 edges of Ce in CeO 2 has been made and a procedure for obtaining structural parameters from L 3 -edge EXAFS, even in the presence of these features, has been developed. This procedure could allow further studies of catalytic compounds containing tetravalent cerium surrounded by oxygen ligands. (au)

  4. Rapid disinhibition by adjustment of PV intrinsic excitability during whisker map plasticity in mouse S1.

    Science.gov (United States)

    Gainey, Melanie A; Aman, Joseph W; Feldman, Daniel E

    2018-04-20

    Rapid plasticity of layer (L) 2/3 inhibitory circuits is an early step in sensory cortical map plasticity, but its cellular basis is unclear. We show that, in mice of either sex, 1 day whisker deprivation drives rapid loss of L4-evoked feedforward inhibition and more modest loss of feedforward excitation in L2/3 pyramidal (PYR) cells, increasing E-I conductance ratio. Rapid disinhibition was due to reduced L4-evoked spiking by L2/3 parvalbumin (PV) interneurons, caused by reduced PV intrinsic excitability. This included elevated PV spike threshold, associated with an increase in low-threshold, voltage activated delayed rectifier (presumed Kv1) and A-type potassium currents. Excitatory synaptic input and unitary inhibitory output of PV cells were unaffected. Functionally, the loss of feedforward inhibition and excitation were precisely coordinated in L2/3 PYR cells, so that peak feedforward synaptic depolarization remained stable. Thus, rapid plasticity of PV intrinsic excitability offsets early weakening of excitatory circuits to homeostatically stabilize synaptic potentials in PYR cells of sensory cortex. SIGNIFICANCE STATEMENT Inhibitory circuits in cerebral cortex are highly plastic, but the cellular mechanisms and functional importance of this plasticity are incompletely understood. We show that brief (1-day) sensory deprivation rapidly weakens parvalbumin (PV) inhibitory circuits by reducing the intrinsic excitability of PV neurons. This involved a rapid increase in voltage-gated potassium conductances that control near-threshold spiking excitability. Functionally, the loss of PV-mediated feedforward inhibition in L2/3 pyramidal cells was precisely balanced with the separate loss of feedforward excitation, resulting in a net homeostatic stabilization of synaptic potentials. Thus, rapid plasticity of PV intrinsic excitability implements network-level homeostasis to stabilize synaptic potentials in sensory cortex. Copyright © 2018 the authors.

  5. Response times of Cassini/INCA > 5.2 keV ENAs and Voyager ions in the heliosheath over the solar cycle

    Science.gov (United States)

    Dialynas, K.; Krimigis, S. M.; Mitchell, D. G.; Decker, R. B.; Roelof, E. C.

    2017-09-01

    Both a magnetosphere-like tail and a bubble model of the heliosphere were posited by E. N. Parker in 1961. Recently, we showed that heliosheath ions are the source of > 5.2 keV Energetic Neutral Atoms (ENA), whose images of the heliosphere exhibit a rough nose to anti-nose (tail) global symmetry that resembles a diamagnetic bubble. The comparison between energetic neutral atom (ENA) global images of the helioshphere obtained with the Ion and Neutral Camera (INCA) on board Cassini and ions measured in-situ by the Low Energy Charged Particle experiment (LECP) on board Voyager 1 and 2 (V1/V2) in overlapping energy bands over an 11-year period shows that the heliosphere responds promptly, within ∼2-3 years, to outward propagating solar wind changes in both the nose and tail directions. Here we focus on the recovery of solar cycle 24 and the response times of > 5.2 keV ENAs to show that this ∼2-3-year time delay is consistent with a “tail” of ∼80-120 AU. This preliminary rough calculation is generally consistent with lower energy ENA data (E < 6 keV, from the IBEX-Lo and IBEX-Hi) and is supported by recent modelling of the heliosphere.

  6. The Context for IMAP: Voyager and INCA Observations of the Heliosheath at E > 5 keV

    Science.gov (United States)

    Krimigis, Stamatios M.

    2016-04-01

    The basic premise of the proposed Interstellar Mapping and Acceleration Probe (IMAP) is detailed scientific understanding of the Heliosheath (HS) and beyond, a region of space explored in situ by Voyager 1 (V1) since 2004, Voyager 2 (V2) since 2007, and remotely via energetic neutral atoms (ENA) by the Cassini/INCA (Ion and Neutral CAmera) since 2003 and IBEX since 2009. The IMAP instrumentation proposed for this purpose combines and extends the IBEX and INCA ENA energy ranges (0.3- 20 keV and 3-200 keV, for low and high energy, respectively). All three missions-Voyagers, Cassini/INCA, and IBEX- have made discovery-class measurements in the HS, the Voyagers providing in situ ion intensities at E > 30 keV, while INCA images ENA in the range 5 INCA ENA allows for the possibility of observing the intensity and time evolution of ions in the HS, thought to give rise to the ENAs via charge-exchange, and the resultant ENA images in the inner heliosphere and their spatial and/or temporal variability. Unfortunately, no such "ground truth" ion measurements are possible at Voyager in the ENA energy range imaged by IBEX. Some of the key findings from the Voyager and Cassini/INCA measurements are as follows: (1) The HS contains a hot plasma population that carries a substantial part (30-50 %) of the total pressure at E > 5 keV, the rest residing below that range, resulting in a beta (particle/magnetic pressure) always > 1, typically >10. (2) The width of the HS in the direction of V1 is ~ 30 AU, but is thought to be larger (40-70 AU) in the southern ecliptic where V2 currently travels.. (3) The ENA intensities at E > 5 keV exhibit a correlation with the solar cycle (SC) over the period 2003 to 2015, with minimum intensities in the anti-nose direction observed ~ 1.5 yrs after solar minimum followed by a recovery thereafter. (4) The in situ ion measurements at V2 within the HS also show a similar SC dependence. The totality of the observations, together with the near

  7. On the morphology of energetic (>= 30 keV) electron precipitation at the onset of negative magnetic bays

    International Nuclear Information System (INIS)

    Pytte, T.; Trefall, H.; Kremser, G.; Tanskanen, P.; Riedler, W.

    1976-01-01

    Recordings of Bremsstrahlung X-rays supported by recordings of cosmic noise absorption have been used to study in detail energetic (>= 30 keV) electron precipitation events occurring near local midnight at the onset of the expansion phase of magnetospheric substorms. This type of precipitation occurs during the first 5 to 10 min after bay onset and can usually be distinguished from the subsequent bay-associated precipitation by its characteristic time structure, variation in energy spectrum, and higher intensities. During this same interval, the poleward border of the precipitation region moves rapidly towards higher latitudes with speeds of typically 1 to 2 km/s, whereas the equatorward border seems to move slowly towards lower latitudes. The northward expansion starts just poleward of the lowest latitudes reached during the slow equatorward motion of the preceding growth-phase precipitation. The previous narrow precipitation region may thus expand to as much as 10 0 of invariant latitude within a few minutes. Within the expanding region there are additional intrinsic temporal variations. As the flux of precipitating electrons tends to be most intense and most energetic near the poleward border, recordings made northward of the latitude where the poleward motion started tend to give the appearance of an impulsive precipiation event. The bay-onset precipiation starts abruptly at the onset of Pi 2 magnetic pulsations. Associated with these pulsations there are modulations of the flux of precipitating electrons. An intensified westward electrojet appears to have its center in the equatorward part of the precipitation region. The results are discussed and a mechanism is proposed. (author)

  8. HGMF of 10-L solutions

    International Nuclear Information System (INIS)

    Larkin, K.A.

    1994-01-01

    This test plan describes the activities associated with the High Gradient Magnetic Filtration (HGMF) of plutonium-bearing solutions (10-L). The 10-L solutions were received from Argonne National Laboratories in 1972, are highly acidic, and are considered unstable. The purpose of the testing is to show that HGMF is an applicable method of removing plutonium precipitates from solution. The plutonium then can be stored safely in a solid form

  9. Testing and Comparison of Imaging Detectors for Electrons in the Energy Range 10-20 keV

    Science.gov (United States)

    Matheson, J.; Moldovan, G.; Kirkland, A.; Allinson, N.; Abrahams, J. P.

    2017-11-01

    Interest in direct detectors for low-energy electrons has increased markedly in recent years. Detection of electrons in the energy range up to low tens of keV is important in techniques such as photoelectron emission microscopy (PEEM) and electron backscatter diffraction (EBSD) on scanning electron microscopes (SEMs). The PEEM technique is used both in the laboratory and on synchrotron light sources worldwide. The ubiquity of SEMs means that there is a very large market for EBSD detectors for materials studies. Currently, the most widely used detectors in these applications are based on indirect detection of incident electrons. Examples include scintillators or microchannel plates (MCPs), coupled to CCD cameras. Such approaches result in blurring in scintillators/phosphors, distortions in optical systems, and inefficiencies due the limited active area of MCPs. In principle, these difficulties can be overcome using direct detection in a semiconductor device. Growing out of a feasibility study into the use of a direct detector for use on an XPEEM, we have built at Rutherford Appleton Laboratory a system to illuminate detectors with an electron beam of energy up to 20 keV . We describe this system in detail. It has been used to measure the performance of a custom back-thinned monolithic active pixel sensor (MAPS), a detector based on the Medipix2 chip, and a commercial detector based on MCPs. We present a selection of the results from these measurements and compare and contrast different detector types.

  10. A systematic study of the condensation of the corona and the application for Γ 2-10 keV-Lbol/LEdd correlation in luminous active galactic nuclei

    Science.gov (United States)

    Qiao, Erlin; Liu, B. F.

    2018-06-01

    In this paper, we explained the observed Γ _2-10 keV-L_bol/L_Edd correlation in luminous active galactic nuclei within the framework of the condensation of the corona around a supermassive black hole (Liu et al.; Qiao & Liu). Specifically, we systemically test the effects of black hole mass M, the viscosity parameter α, and the magnetic parameter β (with magnetic pressure p_m=B^2/{8π }=(1-β )p_tot, ptot = pgas + pm) on the structure of the accretion disc and the corona, as well as the corresponding emergent spectra. It is found that the hard X-ray photon index Γ _2-10 keV nearly does not change with changing black hole mass M, or changing magnetic parameter β. Meanwhile, it is found that the geometry of the accretion flow, i.e. the relative configuration of the disc and corona, as well as the emergent spectra can be strongly affected by changing the value of α. By comparing with a sample composed of 29 luminous active galactic nuclei with well constrained X-ray spectra and Eddington ratios, it is found that the observed Γ _2-10 keV-L_bol/L_Edd correlation can be well matched with a relatively bigger value of α, i.e. α ˜ 1, as previously also suggested by Narayan for luminous accreting black holes.

  11. Radiation defect distribution in silicon irradiated with 600 keV electrons

    International Nuclear Information System (INIS)

    Hazdra, P.; Dorschner, H.

    2003-01-01

    Low-doped n-type float zone silicon was irradiated with 600 keV electrons to fluences from 2x10 13 to 1x10 15 cm -2 . Radiation defects, their introduction rates and full-depth profiles were measured by two complementary methods - the capacitance deep level spectroscopy and the high-voltage current transient spectroscopy. Results show that, in the vicinity of the anode junction, the profile of vacancy-related defect centers is strongly influenced by electric field and an excessive generation of vacancies. In the bulk, the slope of the profile can be derived from the distribution of absorbed dose taking into the account the threshold energy necessary for Frenkel pair formation and the dependency of the defect introduction rate on electron energy

  12. X-ray spectrometer having 12 000 resolving power at 8 keV energy

    Science.gov (United States)

    Seely, John F.; Hudson, Lawrence T.; Henins, Albert; Feldman, Uri

    2017-10-01

    An x-ray spectrometer employing a thin (50 μm) silicon transmission crystal was used to record high-resolution Cu Kα spectra from a laboratory x-ray source. The diffraction was from the (331) planes that were at an angle of 13.26° to the crystal surface. The components of the spectral lines resulting from single-vacancy (1s) and double-vacancy (1s and 3d) transitions were observed. After accounting for the natural lifetime widths from reference double-crystal spectra and the spatial resolution of the image plate detector, the intrinsic broadening of the transmission crystal was measured to be as small as 0.67 eV and the resolving power 12 000, the highest resolving power achieved by a compact (0.5 m long) spectrometer employing a single transmission crystal operating in the hard x-ray region. By recording spectra with variable source-to-crystal distances and comparing to the calculated widths from various geometrical broadening mechanisms, the primary contributions to the intrinsic crystal broadening were found to be the source height at small distances and the crystal apertured height at large distances. By reducing these two effects, using a smaller source size and vignetting the crystal height, the intrinsic crystal broadening is then limited by the crystal thickness and the rocking curve width and would be 0.4 eV at 8 keV energy (20 000 resolving power).

  13. Molecular structure and vibrational spectrum of the complex [ErL(H2O)(NO3)3] (L 1,4,10,13-tetraoxi-7,16-diaza(diphenylphosphinylmethyl) cyclooctadecane

    International Nuclear Information System (INIS)

    Minacheva, L.Kh.; Ivanova, I.S.; Kireeva, I.K.; Sakharova, V.G.; Tsivadze, A.Yu.; Sergienko, V.S.; Baulin, V.E.

    2000-01-01

    Synthesis of podandocoronand on the basis of diazo-18-crown-6 (DA18K6) 1,4,10,13-tetraoxi-7,16-diazo (diphenylphosphynylmethyl)cyclooctadecane (L) and erbium nitrate complex with L of the [ErL(H 2 O)(NO 3 ) 3 ] (I) composition is described. The IR-spectra of the free ligand L and complex I are studied and interpreted.The crystals are monoclinic: a = 10.432(2), b = 19.909(4), c = 21.361(4), β = 100.39(3) Deg, V = 4364(2) A 3 , sp. gr. P2 1 /n, Z = 4, ρ = 1.617 g/cm 3 . The structure I is formed of discrete molecular complexes. The Er atom coordination number is equal to 9. Three nitrate groups are bidentate-cyclic coordinated; two of them are in trans-position to each other; the H 2 O molecule is trans-position to the third NO 3 -group. The ligand L is coordinated by metal through two oxygen phosphoryl atoms. Thus, the Er atom coordination polyhedron may be described as octahedron, if each NO 3 -group occupies one coordination position. The Er-O(L) and Er-O(NO 3 ) overage distances are equal to 2.25 and 2.43 A correspondingly. Er-O(H 2 O) - 2.29 A. The H 2 O coordinated molecule forms intermolecular hydrogen atom and two oxygen atoms of the DA18K6 macrocycle [ru

  14. Momentum mapping spectrometer for probing the fragmentation dynamics of molecules induced by keV electrons

    International Nuclear Information System (INIS)

    Singh, Raj; Bhatt, Pragya; Yadav, Namita; Shanker, R

    2011-01-01

    We describe a new experimental setup for studying the fragmentation dynamics of molecules induced by the impact of keV electrons using the well-known technique of recoil ion momentum spectroscopy. The apparatus consists of mainly a time- and position-sensitive multi-hit particle detector for ion analysis and a channel electron multiplier detector for detecting the ejected electrons. Different components of the setup and the relevant electronics for data acquisition are described in detail with their working principles. In order to verify the reliable performance of the setup, we have recorded the collision-induced ionic spectra of the CO 2 molecule by the impact of keV electrons. Information about the ion pairs of CO + :O + , C + :O + and O + :O + resulting from dissociative ionizing collisions of 20 and 26 keV electrons with a dilute gaseous target of CO 2 molecules has been obtained. Under conditions of the present experiment, the momentum resolutions of the spectrometer for the combined momenta of CO + and O + ions in the direction of the time-of-flight axis and perpendicular to the direction of an electron beam are found to be 10.0 ± 0.2 and 15.0 ± 0.3 au, respectively

  15. MicroRNA-10b downregulation mediates acute rejection of renal allografts by derepressing BCL2L11

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xiaoyou [Department of Organ Transplantation, Zhujiang Hospital, Guangzhou 510282 (China); Dong, Changgui [Institute of Molecular Ecology and Evolution, East China Normal University, Shanghai 200062 (China); Jiang, Zhengyao [Department of Organ Transplantation, Zhujiang Hospital, Guangzhou 510282 (China); Wu, William K.K. [Department of Anaesthesia and Intensive Care, The Chinese University of Hong Kong, Shatin, NT, Hong Kong (China); State Key Laboratory of Digestive Diseases, LKS Institute of Health Sciences, The Chinese University of Hong Kong, Shatin, NT, Hong Kong (China); Chan, Matthew T.V. [Department of Anaesthesia and Intensive Care, The Chinese University of Hong Kong, Shatin, NT, Hong Kong (China); Zhang, Jie [Department of Organ Transplantation, Zhujiang Hospital, Guangzhou 510282 (China); Li, Haibin; Qin, Ke [Guangxi Key Laboratory for Transplantation Medicine Department of Organ Transplantation in Guangzhou Military Region, Institute of Transplant Medicine, 303 Hospital of People' s Liberation Army, Nanning, Guangxi 530021 (China); Sun, Xuyong, E-mail: sunxuyong0528@163.com [Guangxi Key Laboratory for Transplantation Medicine Department of Organ Transplantation in Guangzhou Military Region, Institute of Transplant Medicine, 303 Hospital of People' s Liberation Army, Nanning, Guangxi 530021 (China)

    2015-04-10

    Kidney transplantation is the major therapeutic option for end-stage kidney diseases. However, acute rejection could cause allograft loss in some of these patients. Emerging evidence supports that microRNA (miRNA) dysregulation is implicated in acute allograft rejection. In this study, we used next-generation sequencing to profile miRNA expression in normal and acutely rejected kidney allografts. Among 75 identified dysregulated miRNAs, miR-10b was the most significantly downregulated miRNAs in rejected allografts. Transfecting miR-10b inhibitor into human renal glomerular endothelial cells recapitulated key features of acute allograft rejection, including endothelial cell apoptosis, release of pro-inflammatory cytokines (interleukin-6, tumor necrosis factor α, interferon-γ, and chemokine (C–C motif) ligand 2) and chemotaxis of macrophages whereas transfection of miR-10b mimics had opposite effects. Downregulation of miR-10b directly derepressed the expression of BCL2L11 (an apoptosis inducer) as revealed by luciferase reporter assay. Taken together, miR-10b downregulation mediates many aspects of disease pathogenicity of acute kidney allograft rejection. Restoring miR-10b expression in glomerular endothelial cells could be a novel therapeutic approach to reduce acute renal allograft loss. - Highlights: • miR-10b was the most downregulated microRNAs in acutely rejected renal allografts. • miR-10b downregulation triggered glomerular endothelial cell apoptosis. • miR-10b downregulation induced release of pro-inflammatory cytokines. • miR-10b downregulation derepressed its pro-apoptotic target BCL2L11.

  16. MicroRNA-10b downregulation mediates acute rejection of renal allografts by derepressing BCL2L11

    International Nuclear Information System (INIS)

    Liu, Xiaoyou; Dong, Changgui; Jiang, Zhengyao; Wu, William K.K.; Chan, Matthew T.V.; Zhang, Jie; Li, Haibin; Qin, Ke; Sun, Xuyong

    2015-01-01

    Kidney transplantation is the major therapeutic option for end-stage kidney diseases. However, acute rejection could cause allograft loss in some of these patients. Emerging evidence supports that microRNA (miRNA) dysregulation is implicated in acute allograft rejection. In this study, we used next-generation sequencing to profile miRNA expression in normal and acutely rejected kidney allografts. Among 75 identified dysregulated miRNAs, miR-10b was the most significantly downregulated miRNAs in rejected allografts. Transfecting miR-10b inhibitor into human renal glomerular endothelial cells recapitulated key features of acute allograft rejection, including endothelial cell apoptosis, release of pro-inflammatory cytokines (interleukin-6, tumor necrosis factor α, interferon-γ, and chemokine (C–C motif) ligand 2) and chemotaxis of macrophages whereas transfection of miR-10b mimics had opposite effects. Downregulation of miR-10b directly derepressed the expression of BCL2L11 (an apoptosis inducer) as revealed by luciferase reporter assay. Taken together, miR-10b downregulation mediates many aspects of disease pathogenicity of acute kidney allograft rejection. Restoring miR-10b expression in glomerular endothelial cells could be a novel therapeutic approach to reduce acute renal allograft loss. - Highlights: • miR-10b was the most downregulated microRNAs in acutely rejected renal allografts. • miR-10b downregulation triggered glomerular endothelial cell apoptosis. • miR-10b downregulation induced release of pro-inflammatory cytokines. • miR-10b downregulation derepressed its pro-apoptotic target BCL2L11

  17. EMISSION LINES BETWEEN 1 AND 2 keV IN COMETARY X-RAY SPECTRA

    Energy Technology Data Exchange (ETDEWEB)

    Ewing, Ian; Christian, Damian J. [Department of Physics and Astronomy, California State University, 18111 Nordhoff Street, Northridge, CA 91330 (United States); Bodewits, Dennis [Department of Astronomy, University of Maryland, College Park, MD 20742 (United States); Dennerl, Konrad [Max-Planck-Institut fuer extraterrestrische Physik, Postfach 1312, D-85741 Garching Germany (Germany); Lisse, Carey M. [Planetary Exploration Group, Space Department, Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Rd, Laurel, MD 20723 (United States); Wolk, Scott J., E-mail: ian.ewing.794@my.csun.edu, E-mail: daman.christian@csun.edu [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States)

    2013-01-20

    We present the detection of new cometary X-ray emission lines in the 1.0-2.0 keV range using a sample of comets observed with the Chandra X-Ray Observatory and ACIS spectrometer. We have selected five comets from the Chandra sample with good signal-to-noise spectra. The surveyed comets are C/1999 S4 (LINEAR), C/1999 T1 (McNaught-Hartley), 153P/2002 (Ikeya-Zhang), 2P/2003 (Encke), and C/2008 8P (Tuttle). We modeled the spectra with an extended version of our solar wind charge exchange (SWCX) emission model. Above 1 keV, we find Ikeya-Zhang to have strong emission lines at 1340 and 1850 eV which we identify as being created by SWCX lines of Mg XI and Si XIII, respectively, and weaker emission lines at 1470, 1600, and 1950 eV formed by SWCX of Mg XII, Mg XI, and Si XIV, respectively. The Mg XI and XII and Si XIII and XIV lines are detected at a significant level for the other comets in our sample (LS4, MH, Encke, 8P), and these lines promise additional diagnostics to be included in SWCX models. The silicon lines in the 1700-2000 eV range are detected for all comets, but with the rising background and decreasing cometary emission, we caution that these detections need further confirmation with higher resolution instruments.

  18. Intrinsic Functional Connectivity in the Adult Brain and Success in Second-Language Learning.

    Science.gov (United States)

    Chai, Xiaoqian J; Berken, Jonathan A; Barbeau, Elise B; Soles, Jennika; Callahan, Megan; Chen, Jen-Kai; Klein, Denise

    2016-01-20

    There is considerable variability in an individual's ability to acquire a second language (L2) during adulthood. Using resting-state fMRI data acquired before training in English speakers who underwent a 12 week intensive French immersion training course, we investigated whether individual differences in intrinsic resting-state functional connectivity relate to a person's ability to acquire an L2. We focused on two key aspects of language processing--lexical retrieval in spontaneous speech and reading speed--and computed whole-brain functional connectivity from two regions of interest in the language network, namely the left anterior insula/frontal operculum (AI/FO) and the visual word form area (VWFA). Connectivity between the left AI/FO and left posterior superior temporal gyrus (STG) and between the left AI/FO and dorsal anterior cingulate cortex correlated positively with improvement in L2 lexical retrieval in spontaneous speech. Connectivity between the VWFA and left mid-STG correlated positively with improvement in L2 reading speed. These findings are consistent with the different language functions subserved by subcomponents of the language network and suggest that the human capacity to learn an L2 can be predicted by an individual's intrinsic functional connectivity within the language network. Significance statement: There is considerable variability in second-language learning abilities during adulthood. We investigated whether individual differences in intrinsic functional connectivity in the adult brain relate to success in second-language learning, using resting-state functional magnetic resonance imaging in English speakers who underwent a 12 week intensive French immersion training course. We found that pretraining functional connectivity within two different language subnetworks correlated strongly with learning outcome in two different language skills: lexical retrieval in spontaneous speech and reading speed. Our results suggest that the human

  19. Calibration efficiency of HPGe detector in the 50-1800 KeV energy range; Calibracao em eficiencia de um detector HPGe na faixa de energias 50 - 1800KeV

    Energy Technology Data Exchange (ETDEWEB)

    Venturini, Luzia [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil). Servico de Monitoracao Ambiental

    1996-07-01

    This paper describes the efficiency of an HPGe detector in the 50 - 1800 keV energy range, for two geometries for water measurements: Marinelli breaker (850 ml) and a polyethylene flask (100 ml). The experimental data were corrected for the summing effect and fitted to a continuous, differentiable and energy dependent function given by 1n({epsilon})=b{sub 0}+b{sub 1}.1n(E/E{sub 0})+ {beta}.1n(E/E{sub 0}){sup 2}, where {beta} = b{sub 2} if E>E{sub 0} and {beta} =a{sub 2} if E {<=}E{sub 0}; {epsilon} = the full absorption peak efficiency; E is the gamma-ray energy and {l_brace}b{sub 0}, b{sub 1}, b{sub 2}, a{sub 2}, E{sub 0} {r_brace} is the parameter set to be fitted. (author)

  20. Measurement of D(d,p)T Reaction Cross Sections in Sm Metal in Low Energy Region (10(≤) Ed(≤)20 keV)

    Institute of Scientific and Technical Information of China (English)

    WANG Tie-Shan; YANG Zhen; H. Yunemura; A. Nakagawa; LV Hui-Yi; CHEN Jian-Yong; LIU Sheng-Jin; J. Kasagi

    2007-01-01

    To study the screening effect of nuclear reactions in metallic environments, the thick target yields, the cross sections and the experimental S(E) factors of the D{d,p)T reaction have been measured on deuterons implanted in Sm metal at 133.2 K for beam energies ranging from 10 to 20keV. The thick target yields of protons emitted in the D(d,p)T reaction are measured and compared with those data extrapolated from cross sections and stopping power data at higher energies. The screening potential in Sm metal at 133.2K is deduced to be 520±56eV. As compared with the value achieved in the gas target, the calculated screening potential values are much larger. This screening potential cannot be simply interpreted only by the electron screening. Energy dependences of the cross section cr(E) and the experimental S(E) factor for D(d,p)T reaction in Sm metal at 133.2K are obtained, respectively.

  1. NuSTAR OBSERVATIONS OF THE COMPTON-THICK ACTIVE GALACTIC NUCLEUS AND ULTRALUMINOUS X-RAY SOURCE CANDIDATE IN NGC 5643

    Energy Technology Data Exchange (ETDEWEB)

    Annuar, A.; Gandhi, P.; Alexander, D. M.; Lansbury, G. B.; Moro, A. Del [Centre for Extragalactic Astronomy, Department of Physics, University of Durham, South Road, Durham, DH1 3LE (United Kingdom); Arévalo, P. [Instituto de Física y Astronomía, Facultad de Ciencias, Universidad de Valparaíso, Gran Bretana N 1111, Playa Ancha, Valparaíso (Chile); Ballantyne, D. R. [Center for Relativistic Astrophysics, School of Physics, Georgia Institute of Technology, Atlanta, GA 30332 (United States); Baloković, M.; Brightman, M.; Harrison, F. A. [Cahill Center for Astronomy and Astrophysics, California Institute of Technology, Pasadena, CA 91125 (United States); Bauer, F. E. [EMBIGGEN Anillo, Concepción (Chile); Boggs, S. E.; Craig, W. W. [Space Sciences Laboratory, University of California, Berkeley, CA 94720 (United States); Brandt, W. N. [Department of Astronomy and Astrophysics, The Pennsylvania State University, 525 Davey Lab, University Park, PA 16802 (United States); Christensen, F. E. [DTU Space, National Space Institute, Technical University of Denmark, Elektrovej 327, DK-2800 Lyngby (Denmark); Hailey, C. J. [Columbia Astrophysics Laboratory, Columbia University, New York, NY 10027 (United States); Hickox, R. C. [Department of Physics and Astronomy, Dartmouth College, 6127 Wilder Laboratory, Hanover, NH 03755 (United States); Matt, G. [Dipartimento di Matematica e Fisica, Universitá degli Studi Roma Tre, via della Vasca Navale 84, I-00146 Roma (Italy); Puccetti, S. [ASI Science Data Center, via Galileo Galilei, I-00044 Frascati (Italy); Ricci, C. [Department of Astronomy, Kyoto University, Kitashirakawa-Oiwake-cho, Sakyo-ku, Kyoto 606-8502 (Japan); and others

    2015-12-10

    We present two Nuclear Spectroscopic Telescope Array (NuSTAR) observations of the local Seyfert 2 active galactic nucleus (AGN) and an ultraluminous X-ray source (ULX) candidate in NGC 5643. Together with archival data from Chandra, XMM-Newton, and Swift-BAT, we perform a high-quality broadband spectral analysis of the AGN over two decades in energy (∼0.5–100 keV). Previous X-ray observations suggested that the AGN is obscured by a Compton-thick (CT) column of obscuring gas along our line of sight. However, the lack of high-quality ≳10 keV observations, together with the presence of a nearby X-ray luminous source, NGC 5643 X–1, have left significant uncertainties in the characterization of the nuclear spectrum. NuSTAR now enables the AGN and NGC 5643 X–1 to be separately resolved above 10 keV for the first time and allows a direct measurement of the absorbing column density toward the nucleus. The new data show that the nucleus is indeed obscured by a CT column of N{sub H} ≳ 5 × 10{sup 24} cm{sup −2}. The range of 210 keV absorption-corrected luminosity inferred from the best-fitting models is L{sub 210,int} = (0.8–1.7) × 10{sup 42} erg s{sup −1}, consistent with that predicted from multiwavelength intrinsic luminosity indicators. In addition, we also study the NuSTAR data for NGC 5643 X–1 and show that it exhibits evidence of a spectral cutoff at energy E ∼ 10 keV, similar to that seen in other ULXs observed by NuSTAR. Along with the evidence for significant X-ray luminosity variations in the 3–8 keV band from 2003 to 2014, our results further strengthen the ULX classification of NGC 5643 X–1.

  2. A New Observation of the Quiet Sun Soft X-ray (0.5-5 keV) Spectrum

    Science.gov (United States)

    Caspi, Amir; Woods, Thomas N.; Stone, Jordan

    2013-03-01

    The solar corona is the brightest source of X-rays in the solar system, and the X-ray emission is highly variable with solar activity. While this is particularly true during solar flares, when emission can be enhanced by many orders of magnitude up to gamma-ray energies, even the so-called "quiet Sun" is bright in soft X-rays (SXRs), as the 1-2 MK ambient plasma of the corona emits significant thermal bremsstrahlung up to 5 keV. However, the actual solar SXR (0.5-5 keV) spectrum is not well known, particularly during quiet periods, as, with few exceptions, this energy range has not been systematically studied in many years. Previous observations include ultra-high-resolution but very narrow-band spectra from crystral spectrometers (e.g. Yohkoh/BCS), or integrated broadband irradiances from photometers (e.g. GOES/XRS, TIMED/XPS, etc.) that lack detailed spectral information. In recent years, broadband measurements with fair energy resolution ( 0.5-0.7 keV FWHM) were made by SphinX on CORONAS-Photon and XRS on MESSENGER, although they did not extend below 1 keV. We present observations of the quiet Sun SXR emission obtained using a new SXR spectrometer flown on the third SDO/EVE underflight calibration rocket (NASA 36.286). The commercial off-the-shelf Amptek X123 silicon drift detector, with an 8-micron Be window and custom aperture, measured the solar SXR emission from 0.5 to >10 keV with 0.15 keV FWHM resolution (though, due to hardware limitations, with only 0.12 keV binning) and 2-sec cadence over 5 minutes on 23 June 2012. Despite the rising solar cycle, activity on 23 June 2012 was abnormally low, with no visible active regions and GOES XRS emission near 2010 levels; we measured no solar counts above 4 keV during the observation period. We compare our X123 measurements with spectra and broadband irradiances from other instruments, including the SphinX observations during the deep solar minimum of 2009, and with upper limits of >3 keV quiet Sun emission

  3. Searching for the 3.5 keV Line in the Stacked Suzaku Observations of Galaxy Clusters

    Science.gov (United States)

    Bulbul, Esra; Markevitch, Maxim; Foster, Adam; Miller, Eric; Bautz, Mark; Lowenstein, Mike; Randall, Scott W.; Smith, Randall K.

    2016-01-01

    We perform a detailed study of the stacked Suzaku observations of 47 galaxy clusters, spanning a redshift range of 0.01-0.45, to search for the unidentified 3.5 keV line. This sample provides an independent test for the previously detected line. We detect a 2sigma-significant spectral feature at 3.5 keV in the spectrum of the full sample. When the sample is divided into two subsamples (cool-core and non-cool core clusters), the cool-core subsample shows no statistically significant positive residuals at the line energy. A very weak (approx. 2sigma confidence) spectral feature at 3.5 keV is permitted by the data from the non-cool-core clusters sample. The upper limit on a neutrino decay mixing angle of sin(sup 2)(2theta) = 6.1 x 10(exp -11) from the full Suzaku sample is consistent with the previous detections in the stacked XMM-Newton sample of galaxy clusters (which had a higher statistical sensitivity to faint lines), M31, and Galactic center, at a 90% confidence level. However, the constraint from the present sample, which does not include the Perseus cluster, is in tension with previously reported line flux observed in the core of the Perseus cluster with XMM-Newton and Suzaku.

  4. ISOTROPIC LUMINOSITY INDICATORS IN A COMPLETE AGN SAMPLE

    International Nuclear Information System (INIS)

    Diamond-Stanic, Aleksandar M.; Rieke, George H.; Rigby, Jane R.

    2009-01-01

    The [O IV] λ25.89 μm line has been shown to be an accurate indicator of active galactic nucleus (AGN) intrinsic luminosity in that it correlates well with hard (10-200 keV) X-ray emission. We present measurements of [O IV] for 89 Seyfert galaxies from the unbiased revised Shapley-Ames (RSA) sample. The [O IV] luminosity distributions of obscured and unobscured Seyferts are indistinguishable, indicating that their intrinsic AGN luminosities are quite similar and that the RSA sample is well suited for tests of the unified model. In addition, we analyze several commonly used proxies for AGN luminosity, including [O III] λ5007 A, 6 cm radio, and 2-10 keV X-ray emission. We find that the radio luminosity distributions of obscured and unobscured AGNs show no significant difference, indicating that radio luminosity is a useful isotropic luminosity indicator. However, the observed [O III] and 2-10 keV luminosities are systematically smaller for obscured Seyferts, indicating that they are not emitted isotropically.

  5. The 7 keV axion dark matter and the X-ray line signal

    International Nuclear Information System (INIS)

    Higaki, Tetsutaro; Takahashi, Fuminobu; Tokyo Univ., Kashiwa

    2014-03-01

    We propose a scenario where the saxion dominates the energy density of the Universe and reheats the standard model sector via the dilatonic coupling, while its axionic partner contributes to dark matter decaying into photons via the same operator in supersymmetry. Interestingly, for the axion mass m a ≅ 7 keV and the decay constant f a ≅10 14-15 GeV, the recently discovered X-ray line at 3.5 keV in the XMM Newton X-ray observatory data can be explained. We discuss various cosmological aspects of the 7 keV axion dark matter such as the production of axion dark matter, the saxion decay process, hot dark matter and isocurvature constraints on the axion dark matter, and the possible baryogenesis scenarios.

  6. Electronic, magnetic, transport, and thermal properties of single-crystalline UF e2A l10

    Science.gov (United States)

    Troć, R.; Samsel-Czekała, M.; Talik, E.; Wawryk, R.; Gajek, Z.; Pasturel, M.

    2015-09-01

    The valence and core-level x-ray photoemission spectra (XPS), performed on an UF e2A l10 single crystal, were measured using the Al Kα radiation. The results of valence XPS show practically two separate regions of spectral intensity, one just at the Fermi level (EF) and the other one being a wide content with its maximum at about 0.8 eV below EF. These give rise to two electronic configurations of the 5 f states in the studied aluminide, itinerant and localized ones, i.e., their dual character. In such a situation the corresponding valence spectra, calculated within the local density approximation (LDA), well explain the former configuration, being responsible for a metallic behavior of the studied compound. Moreover, this behavior is confirmed clearly also by our results of magnetotransport measurements. On the other hand, the obtained magnetic susceptibility, specific heat, electrical resistivity, and thermoelectric power data support very well the local character of the 5 f2 -electron configuration of the U4 + ion in UF e2A l10 having the orthorhombic and cage-type crystal structure. Based on that configuration, the magnetic and thermal characteristics of the compound were modeled by the effective crystal field (CF) potential in the intermediate coupling scheme using initial parameters obtained by the angular overlap model (AOM). The obtained final CF parameters yielded the CF level scheme, composed of only singlets, proper for orthorhombic symmetry. Such a set of singlets reproduces in a satisfactory way both the strongly anisotropic temperature variations of the magnetic susceptibility, measured along the three main crystallographic directions, as well as the Schottky anomaly, evaluated using specific heat results of isomorphic ThF e2A l10 as a phonon reference. Also, the strongly anisotropic behavior of the Seebeck coefficient and its low temperature maxima observed for the compound studied here have been explained roughly by the CF effect.

  7. X-ray absorption spectroscopy in the keV range with laser generated high harmonic radiation

    International Nuclear Information System (INIS)

    Seres, Enikoe; Seres, Jozsef; Spielmann, Christian

    2006-01-01

    By irradiating He and Ne atoms with 3 mJ, 12 fs, near infrared laser pulses from a tabletop laser system, the authors generated spatially and temporally coherent x rays up to a photon energy of 3.5 keV. With this source it is possible to use high-harmonic radiation for x-ray absorption spectroscopy in the keV range. They were able to clearly resolve the L absorption edges of titanium and copper and the K edges of aluminum and silicon. From the fine structure of the x-ray absorption they estimated the interatomic distances

  8. Intrinsic and extrinsic spin Hall effects of Dirac electrons

    International Nuclear Information System (INIS)

    Fukazawa, Takaaki; Kohno, Hiroshi; Fujimoto, Junji

    2017-01-01

    We investigate the spin Hall effect (SHE) of electrons described by the Dirac equation, which is used as an effective model near the L-points in bismuth. By considering short-range nonmagnetic impurities, we calculate the extrinsic as well as intrinsic contributions on an equal footing. The vertex corrections are taken into account within the ladder type and the so-called skew-scattering type. The intrinsic SHE which we obtain is consistent with that of Fuseya et al. It is found that the extrinsic contribution dominates the intrinsic one when the system is metallic. The extrinsic SHE due to the skew scattering is proportional to Δ/n i u, where 2Δ is the band gap, n i is the impurity concentration, and u is the strength of the impurity potential. (author)

  9. Effect of 200 keV Ar+ implantation on optical and electrical properties of polyethyleneterepthalate (PET)

    International Nuclear Information System (INIS)

    Kumar, Rajiv; Goyal, Meetika; Sharma, Ambika; Aggarwal, Sanjeev; Sharma, Annu; Kanjilal, D.

    2015-01-01

    In the present paper we have discussed the effect of 200 keV Ar + ions on the electrical and optical properties of PET samples. PET samples were implanted with 200 keV Ar + ions to various doses ranging from 1×10 15 to 1×10 17 Ar + cm 2 . The changes in the electrical and optical properties of pristine and implanted PET specimens have been studied by using Keithley electrometer and UV-Visible absorption spectroscopy. The electrical conductivity has found to be increased with increasing ion dose. The optical studies have revealed the drastic alterations in optical band gap from 3.63 eV to 1.48 eV and also increase in number of carbon atoms per cluster from 215 to 537. Further, the change in the electrical conductivity and optical band gap has also been correlated with the formation of conductive islands in the implanted layers of PET

  10. A New Compton-thick AGN in our Cosmic Backyard: Unveiling the Buried Nucleus in NGC 1448 with NuSTAR

    Science.gov (United States)

    Annuar, A.; Alexander, D. M.; Gandhi, P.; Lansbury, G. B.; Asmus, D.; Ballantyne, D. R.; Bauer, F. E.; Boggs, S. E.; Boorman, P. G.; Brandt, W. N.; Brightman, M.; Christensen, F. E.; Craig, W. W.; Farrah, D.; Goulding, A. D.; Hailey, C. J.; Harrison, F. A.; Koss, M. J.; LaMassa, S. M.; Murray, S. S.; Ricci, C.; Rosario, D. J.; Stanley, F.; Stern, D.; Zhang, W.

    2017-02-01

    NGC 1448 is one of the nearest luminous galaxies (L 8-1000μm > 109 L ⊙) to ours (z = 0.00390), and yet the active galactic nucleus (AGN) it hosts was only recently discovered, in 2009. In this paper, we present an analysis of the nuclear source across three wavebands: mid-infrared (MIR) continuum, optical, and X-rays. We observed the source with the Nuclear Spectroscopic Telescope Array (NuSTAR), and combined these data with archival Chandra data to perform broadband X-ray spectral fitting (≈0.5-40 keV) of the AGN for the first time. Our X-ray spectral analysis reveals that the AGN is buried under a Compton-thick (CT) column of obscuring gas along our line of sight, with a column density of N H(los) ≳ 2.5 × 1024 cm-2. The best-fitting torus models measured an intrinsic 2-10 keV luminosity of L {}2-10,{int} = (3.5-7.6) × 1040 erg s-1, making NGC 1448 one of the lowest luminosity CTAGNs known. In addition to the NuSTAR observation, we also performed optical spectroscopy for the nucleus in this edge-on galaxy using the European Southern Observatory New Technology Telescope. We re-classify the optical nuclear spectrum as a Seyfert on the basis of the Baldwin-Philips-Terlevich diagnostic diagrams, thus identifying the AGN at optical wavelengths for the first time. We also present high spatial resolution MIR observations of NGC 1448 with Gemini/T-ReCS, in which a compact nucleus is clearly detected. The absorption-corrected 2-10 keV luminosity measured from our X-ray spectral analysis agrees with that predicted from the optical [O III]λ5007 Å emission line and the MIR 12 μm continuum, further supporting the CT nature of the AGN.

  11. Monte-Carlo simulations of secondary electron emission from CsI, induced by 1-10 keV X-rays and electrons

    International Nuclear Information System (INIS)

    Akkerman, A.; Gibrekhterman, A.; Breskin, A.; Chechik, R.

    1992-05-01

    A model for electron transport and emission in CsI is proposed. It is based on theoretically calculated microscopic cross-sections for electron interaction with the nuclear and the electronic components of the solid. A Monte Carlo program based on this model was developed to simulate secondary electron emission induced by X-rays and electrons in the energy range of 1 to 10 keV. The calculated secondary emission yields agree with existing experimental data. The model provides all necessary characteristics for the design of radiation detectors based on secondary electron emission. It can be expanded to higher incident energies and other alkali halides. (author)

  12. Study of the secondary electron emission during bombardment of metal targets by positive D{sup +} and D{sub 2}{sup +} ions (1960); Etude de l'emission secondaire d'electrons au cours du bombardement de cibles metalliques par des ions positifs D{sup +} et D{sub 2}{sup +} (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Leroy, J [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires; Prelec, K [Institut Rudjer Boskovic, Zagreb (Croatia)

    1960-07-01

    The secondary electron yield {gamma}-bar due to primary positive ions D{sup +} and D{sup +}{sub 2} has been measured in the 70 keV to 300 keV ion energy range. Several metallic targets have been used. The variation of this yield with the angle of incidence is proportional to sec {theta} where {theta} is the angle between the beam of primary ions and the normal to the target surface. The values {gamma}-bar decrease for increasing energy ions. At a given energy all the targets tried gave approximately the same electron yield. (author) [French] Le facteur d'emission secondaire a ete mesure pour des ions positifs D{sup +} et D{sup +}{sub 2} ayant une energie comprise entre 70 keV et 300 keV, sur differentes cibles metalliques. La variation de ce facteur avec l'angle d'incidence suit une loi de la forme {gamma}{sub 0} sec {theta}, {theta} etant l'angle entre le faisceau et la normale a la cible. Les valeurs de {gamma}-bar trouvees decroissent lorsque l'energie des ions incidents augmente, mais sont assez voisines les unes des autres, a une energie donnee, pour les differentes cibles essayees. (auteur)

  13. A novel probe of intrinsic electronic structure: hard X-ray photoemission spectroscopy

    International Nuclear Information System (INIS)

    Takata, Y.; Tamasaku, K.; Nishino, Y.; Miwa, D.; Yabashi, M.; Ikenaga, E.; Horiba, K.; Arita, M.; Shimada, K.; Namatame, H.; Nohira, H.; Hattori, T.; Soedergren, S.; Wannberg, B.; Taniguchi, M.; Shin, S.; Ishikawa, T.; Kobayashi, K.

    2005-01-01

    We have realized hard X-ray (HX) photoemission spectroscopy (PES) with high throughput and high-energy resolution for core level and valence band studies using high-energy and high-brilliance synchrotron radiation at SPring-8. This is a brand new method because large escape depth of high-energy photoelectrons enables us to probe intrinsic bulk states free from surface condition. By use of a newly developed electron energy analyzer and well-focused X-rays, high-energy resolution of 75 meV (E/ΔE 79,000) was realized for 5.95 keV photoelectrons

  14. On the Spectral Hardening at gsim300 keV in Solar Flares

    Science.gov (United States)

    Li, G.; Kong, X.; Zank, G.; Chen, Y.

    2013-05-01

    It has long been noted that the spectra of observed continuum emissions in many solar flares are consistent with double power laws with a hardening at energies gsim300 keV. It is now widely believed that at least in electron-dominated events, the hardening in the photon spectrum reflects an intrinsic hardening in the source electron spectrum. In this paper, we point out that a power-law spectrum of electrons with a hardening at high energies can be explained by the diffusive shock acceleration of electrons at a termination shock with a finite width. Our suggestion is based on an early analytical work by Drury et al., where the steady-state transport equation at a shock with a tanh profile was solved for a p-independent diffusion coefficient. Numerical simulations with a p-dependent diffusion coefficient show hardenings in the accelerated electron spectrum that are comparable with observations. One necessary condition for our proposed scenario to work is that high-energy electrons resonate with the inertial range of the MHD turbulence and low-energy electrons resonate with the dissipation range of the MHD turbulence at the acceleration site, and the spectrum of the dissipation range ~k -2.7. A ~k -2.7 dissipation range spectrum is consistent with recent solar wind observations.

  15. Intrinsic factor in human amniotic fluid as determined by radioimmunoassay

    International Nuclear Information System (INIS)

    Wahlstedt, V.; Stenman, U.-H.; Ylinen, K.; Graesbeck, R.

    1983-01-01

    The intrinsic factor (IF) concentration in 55 human amniotic fluid specimens was determined by radioimmunoassay (RIA). The antiserum was produced by immunizing rabbits with the cobalamin-IF complex isolated from human gastric juice. The median concentration of IF was 0.17 nmol/l and the extreme values <0.07-2.51 nmol/l. Three specimens with a clearly elevated level (0.96, 1.11 and 2.51 nmol/l) were observed. The highest value was associated with a fetal malformation, viz. obstruction of the proximal gut. There was no evident correlation between the concentration of IF in amniotic fluid and gestational age. (author)

  16. Development of a monoenergetic 1-10 keV neutral lithium beam for the diagnostic of edge plasmas in magnetic confinement devices

    International Nuclear Information System (INIS)

    Ueda, Mario.

    1994-09-01

    Diagnostic of plasmas confined by magnetic fields for fusion research based on neutral lithium beam (NLB) is presently considered to be one of the most appropriate methods to carry out the important measurements of edge density and its fluctuation profiles without plasma perturbation. In this CRP project we proposed the development of an NLB source with 1-10 KeV based on a traditional β-eucryptite surface emission source coupled to a Pierce gun geometry accelerator and subsequent neutralization of the Li + beam by a Li-oven neutralizer. Possible application of such an NLB probe in a medium term (2-3 years) in our country would be in a small RFP in operation and in a low-aspect-ratio tokamak in construction both at LAP/INPE and in other hot plasma devices operating at brazilian universities of Sao Paulo (USP) and Campinas (UNICAMP) with whom we maintain strong collaboration efforts in plasma research. (author). 8 refs

  17. Linear and mass attenuation coefficient for CdTe compound of X-rays from 10 to 100 keV energy range in different phases

    Energy Technology Data Exchange (ETDEWEB)

    Saim, A., E-mail: saim1989asma@gmail.com; Tebboune, A.; Berkok, H.; Belameiri, N.; Belbachir, A.H.

    2014-07-25

    The Full Potential Linear Muffin Tin Orbitals method within the density functional theory has been utilized to calculate structural and electronic properties of the CdTe compound. We have checked that the CdTe has two phase-transitions from zinc-blend to cinnabar and from cinnabar to rocksalt. We have found that the rigidity, the energy and the nature of the gap change according to the phase change, so we can predict that a CdTe detector may have different behaviors in different phase conditions. In order to investigate this behavior change, the linear and the mass attenuation coefficients of X-ray in rocksalt, zinc-blend and cinnabar structures are calculated from 10 keV to100 keV, using the XCOM data. We have found that when CdTe undergoes a phase transition from zinc-blend to cinnabar, its linear attenuation coefficient decreases down to a value of about 100 times smaller than its initial one, and when it undergoes a transition from cinnabar to rocksalt it increases up to a value about 90 times larger than its initial one.

  18. Yield of chromosomal aberrations and recoil particle range in Chineses hamster fibroblasts exposed to 8.5 to 500 keV neutrons

    International Nuclear Information System (INIS)

    Sturelid, S.; Bergman, R.

    1976-01-01

    Induction of chromatid aberrations in S-phase Chinese hamster fibroblasts has been studied for irradiation by 60 Co gamma rays and neutrons of average energy 8.5, 45, 83, 200 and 500 keV. At 10 per cent aberration level the relative biological afficiency varied between 2.2 +- 0.6 (at 8.5 keV) and a maximum of 47 +- 9 (at 200 keV). The neutron generated recoils have short range in comparison to chromosomal dimensions. The strong variation with neutron energy is therefore not necessarily reflecting variations in the average linear energy transfer. Good agreement between experimental and predicted response was obtained when effects ascribed to range were considered. A critical volume within which primary lesions should occur in order to make chromosomal aberrations probable was derived. The corresponding site radius was estimated to be 1-3 μm. (author)

  19. Protection and measurement systems for 500 keV DC industrial accelerator

    International Nuclear Information System (INIS)

    Rajan, R.N.; Saroj, P.C.; Nanu, K.; Sharma, D.K.; Bakhtsingh, R.I.; Pandey, M.K.; Aggarwal, Ritu; Nagesh, K.V.; Sethi, R.C.

    2003-01-01

    A 500 keV, 20 ma electron beam accelerator has been developed and commissioned for industrial processing application at BRIT, Vashi. The 500 kV supply system consists of a 10 kV/2a DC power supply, 15 kW/10 kHz oscillator, 60 kV/10 kHz step-up transformer, and a 10 stage balanced Cockcroft-Walton multiplier. Since this is a high voltage system, and is prone to generate high electrical surges in the event of fault, adequate protection measures have to be incorporated to prevent catastrophic failure to the components of the supply system and also for measurement and control devices. Two level safety protection schemes have been incorporated in this system. This paper describes about various safety measures incorporated in the system and a few system specific measurement schemes

  20. The 7 keV axion dark matter and the X-ray line signal

    Energy Technology Data Exchange (ETDEWEB)

    Higaki, Tetsutaro [KEK, Tsukuba (Japan). Theory Center; Jeong, Kwang Sik [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Takahashi, Fuminobu [Tohoku Univ., Sendai (Japan). Dept. of Physics; Tokyo Univ., Kashiwa (Japan). Kavli IPMU, TODIAS

    2014-03-15

    We propose a scenario where the saxion dominates the energy density of the Universe and reheats the standard model sector via the dilatonic coupling, while its axionic partner contributes to dark matter decaying into photons via the same operator in supersymmetry. Interestingly, for the axion mass m{sub a} ≅ 7 keV and the decay constant f{sub a} ≅10{sup 14-15} GeV, the recently discovered X-ray line at 3.5 keV in the XMM Newton X-ray observatory data can be explained. We discuss various cosmological aspects of the 7 keV axion dark matter such as the production of axion dark matter, the saxion decay process, hot dark matter and isocurvature constraints on the axion dark matter, and the possible baryogenesis scenarios.

  1. THE XMM-NEWTON X-RAY SPECTRA OF THE MOST X-RAY LUMINOUS RADIO-QUIET ROSAT BRIGHT SURVEY-QSOs: A REFERENCE SAMPLE FOR THE INTERPRETATION OF HIGH-REDSHIFT QSO SPECTRA

    International Nuclear Information System (INIS)

    Krumpe, M.; Markowitz, A.; Lamer, G.; Corral, A.

    2010-01-01

    We present the broadband X-ray properties of four of the most X-ray luminous (L X ≥ 10 45 erg s -1 in the 0.5-2 keV band) radio-quiet QSOs found in the ROSAT Bright Survey. This uniform sample class, which explores the extreme end of the QSO luminosity function, exhibits surprisingly homogenous X-ray spectral properties: a soft excess with an extremely smooth shape containing no obvious discrete features, a hard power law above 2 keV, and a weak narrow/barely resolved Fe Kα fluorescence line for the three high signal-to-noise ratio (S/N) spectra. The soft excess can be well fitted with only a soft power law. No signatures of warm or cold intrinsic absorbers are found. The Fe Kα centroids and the line widths indicate emission from neutral Fe (E = 6.4 keV) originating from cold material from distances of only a few light days or further out. The well-constrained equivalent widths (EW) of the neutral Fe lines are higher than expected from the X-ray Baldwin effect which has been only poorly constrained at very high luminosities. Taking into account our individual EW measurements, we show that the X-ray Baldwin effect flattens above L X ∼ 10 44 erg s -1 (2-10 keV band) where an almost constant (EW) of ∼100 eV is found. We confirm the assumption of having very similar X-ray active galactic nucleus properties when interpreting stacked X-ray spectra. Our stacked spectrum serves as a superb reference for the interpretation of low S/N spectra of radio-quiet QSOs with similar luminosities at higher redshifts routinely detected by XMM-Newton and Chandra surveys.

  2. Determination of Intrinsic Permeability for Packed Waste of Indonesian Solid Waste

    Directory of Open Access Journals (Sweden)

    Benno Rahardyan

    2010-11-01

    Full Text Available Gas permeability and intrinsic permeability are the major parameters to promote aeration for packed waste. The objectives of this research are to identify physical parameters of gas transfer from a various type of packed wastes and examine ventilation design theory for landfill to enhance waste stabilization. Method to determine value of gas permeability and intrinsic permeability for packed waste is by flushing the packed column containing various type and physical characteristics of wastes with an air pump. Permeability was calculated by measuring pressure gradient on sampling points of the column using inclined manometer at distance 10 cm, 23 cm, 46 cm, 69 cm, 92 cm and 115 cm from origin. Gas permeability is specifically relied on physical parameters of wastes as follows, density, moisture content, particle size and gas velocity on the surface of compacted waste layer. Compost has finer pore structure and smaller pore size than leaves as well as mixed organic (65% and inorganic wastes (35%. The experiment found the intrinsic permeability of leaves waste are in the order of 10-11 to 10-8 m2, 10-11 to 10-9 m2 for compost and 10-9 m2 for mixed organic (65% and inorganic wastes (35%.

  3. A low background-rate detector for ions in the 5 to 50 keV energy range to be used for radioisotope dating with a small cyclotron

    International Nuclear Information System (INIS)

    Friedman, P.G.

    1986-01-01

    Accelerator mass spectrometry in tandem Van de Graaff accelerators has proven successful for radioisotope dating small samples. We are developing a 20 cm diameter 30 to 40 keV cyclotron dedicated to high-sensitivity radioisotope dating, initially for 14 C. At this energy, range and dE/dx methods of particle identification are impossible. Thus arises the difficult problem of reliably detecting 30 to 40 keV 14 C at 10 -2 counts/sec in the high background environment of the cyclotron, where lower energy ions, electrons, and photons bombard the detector at much higher rates. We have developed and tested an inexpensive, generally useful ion detector that allows dark-count rates below 10 -4 counts/sec and excellent background suppression. With the cyclotron tuned near the 13 CH background peak, to the frequency for 14 C, the detector suppresses the background to 6 x 10 -4 counts/sec. For each 14 C ion the detectors grazing-incidence Al 2 O 3 conversion dynode emits about 20 secondary electrons, which are independently multiplied in separate pores of a microchannel plate. The output signal is proportional to the number of secondary electrons, allowing pulse-height discrimination of background. We have successfully tested the detector with positive 12 C, 23 Na, 39 K, 41 K, 85 Rb, 87 Rb, and 133 Cs at 5 to 40 keV, and with 36 keV negative 12 C and 13 CH. It should detect ions and neutrals of all species, at energies above 5 keV, with good efficiency and excellent background discrimination. Counting efficiency and background discrimination improve with higher ion energy. The detector can be operated at least up to 2 x 10 -7 Torr and be repeatedly exposed to air. The maximum rate is 10/sup 6.4/ ions/sec in pulse counting mode and 10/sup 9.7/ ions/sec in current integrating mode

  4. A cryogenic electrostatic trap for long-time storage of keV ion beams

    Science.gov (United States)

    Lange, M.; Froese, M.; Menk, S.; Varju, J.; Bastert, R.; Blaum, K.; López-Urrutia, J. R. Crespo; Fellenberger, F.; Grieser, M.; von Hahn, R.; Heber, O.; Kühnel, K.-U.; Laux, F.; Orlov, D. A.; Rappaport, M. L.; Repnow, R.; Schröter, C. D.; Schwalm, D.; Shornikov, A.; Sieber, T.; Toker, Y.; Ullrich, J.; Wolf, A.; Zajfman, D.

    2010-05-01

    We report on the realization and operation of a fast ion beam trap of the linear electrostatic type employing liquid helium cooling to reach extremely low blackbody radiation temperature and residual gas density and, hence, long storage times of more than 5 min which are unprecedented for keV ion beams. Inside a beam pipe that can be cooled to temperatures <15 K, with 1.8 K reached in some locations, an ion beam pulse can be stored at kinetic energies of 2-20 keV between two electrostatic mirrors. Along with an overview of the cryogenic trap design, we present a measurement of the residual gas density inside the trap resulting in only 2×103 cm-3, which for a room temperature environment corresponds to a pressure in the 10-14 mbar range. The device, called the cryogenic trap for fast ion beams, is now being used to investigate molecules and clusters at low temperatures, but has also served as a design prototype for the cryogenic heavy-ion storage ring currently under construction at the Max-Planck Institute for Nuclear Physics.

  5. Ab-initio calculation and experimental observation of room temperature ferromagnetism in 50 keV nitrogen implanted rutile TiO2

    Science.gov (United States)

    Luitel, Homnath; Chakrabarti, Mahuya; Sarkar, A.; Dechoudhury, S.; Bhowmick, D.; Naik, V.; Sanyal, D.

    2018-02-01

    Room temperature magnetic properties of 50 keV N4+ ion beam implanted rutile TiO2 have been theoretically and experimentally studied. Ab-initio calculation under the frame work of density functional theory has been carried out to study the magnetic properties of the different possible nitrogen related defects in TiO2. Spin polarized density of states calculation suggests that both Ninst and NO can induce ferromagnetic ordering in rutile TiO2. In both cases the 2p orbital electrons of nitrogen atom give rise to the magnetic moment in TiO2. The possibility of the formation of N2 molecule in TiO2 system is also studied but in this case no significant magnetic moment has been observed. The magnetic measurements, using SQUID magnetometer, results a ferromagnetic ordering even at room temperature for the 50 keV N4+ ion beam implanted rutile TiO2.

  6. Observations of 35- 10 1600-keV protons and low-frequency waves upstream of interplanetary shocks

    International Nuclear Information System (INIS)

    Sanderson, T.R.; Reinhard, R.; Van Nes, P.; Wenzel, K.P.; Smith, E.J.; Tsurutani, B.T.; California Institute of Technology, Pasadena)

    1985-01-01

    The present investigation is concerned with a comparison of measurements of energetic protons in the range from 35 to 1600 keV and low-frequency waves (periods of approximately 6 s) on ISEE 3 associated with the passage of the large oblique shock of April 5, 1979, which exhibits an extended foreshock. An attempt is made to identify the energy of the particles which are responsible for the waves. Intensity profiles of both waves and particles as a function of upstream distance are compared, taking into account the relation between the energy of the particles and the period of the waves. The considered approach makes it possible to identify protons with energies of a few hundred keV as being responsible for the waves in the extended foreshock. It is believed that the high energy density of the high-energy solar flare protons preceding the shock could be responsible for seed waves which provide the scattering centers necessary for the acceleration of the lower-energy protons via a first-order Fermi mechanism. 31 references

  7. New Observations of Soft X-ray (0.5-5 keV) Solar Spectra

    Science.gov (United States)

    Caspi, A.; Woods, T. N.; Mason, J. P.; Jones, A. R.; Warren, H. P.

    2013-12-01

    The solar corona is the brightest source of X-rays in the solar system, and the X-ray emission is highly variable on many time scales. However, the actual solar soft X-ray (SXR) (0.5-5 keV) spectrum is not well known, particularly during solar quiet periods, as, with few exceptions, this energy range has not been systematically studied in many years. Previous observations include high-resolution but very narrow-band spectra from crystal spectrometers (e.g., Yohkoh/BCS), or integrated broadband irradiances from photometers (e.g., GOES/XRS, TIMED/XPS, etc.) that lack detailed spectral information. In recent years, broadband measurements with moderate energy resolution (~0.5-0.7 keV FWHM) were made by SphinX on CORONAS-Photon and SAX on MESSENGER, although they did not extend to energies below ~1 keV. We present observations of solar SXR emission obtained using new instrumentation flown on recent SDO/EVE calibration rocket underflights. The photon-counting spectrometer, a commercial Amptek X123 with a silicon drift detector and an 8 μm Be window, measures the solar disk-integrated SXR emission from ~0.5 to >10 keV with ~0.15 keV FWHM resolution and 1 s cadence. A novel imager, a pinhole X-ray camera using a cooled frame-transfer CCD (15 μm pixel pitch), Ti/Al/C filter, and 5000 line/mm Au transmission grating, images the full Sun in multiple spectral orders from ~0.1 to ~5 nm with ~10 arcsec/pixel and ~0.01 nm/pixel spatial and spectral detector scales, respectively, and 10 s cadence. These instruments are prototypes for future CubeSat missions currently being developed. We present new results of solar observations on 04 October 2013 (NASA sounding rocket 36.290). We compare with previous results from 23 June 2012 (NASA sounding rocket 36.286), during which solar activity was low and no signal was observed above ~4 keV. We compare our spectral and imaging measurements with spectra and broadband irradiances from other instruments, including SDO/EVE, GOES/XRS, TIMED

  8. 380 keV proton irradiation effects on photoluminescence of Eu-doped GaN

    International Nuclear Information System (INIS)

    Okada, Hiroshi; Nakanishi, Yasuo; Wakahara, Akihiro; Yoshida, Akira; Ohshima, Takeshi

    2008-01-01

    The effect of 380 keV proton irradiation on the photoluminescence (PL) properties has been investigated for undoped and Eu-doped GaN. As the proton irradiation exceeds 1x10 13 cm -2 , a drastic decrease of PL intensity of the near band-edge emission of undoped GaN was observed. On the other hand, for Eu-doped GaN, the PL emission corresponding to the 5 D 0 → 7 F 2 transition in Eu 3+ kept the initial PL intensity after the proton irradiation up to 1x10 14 cm -2 . Present results, together with our previous report on electron irradiation results, suggest that Eu-doped GaN is a strong candidate for light emitting devices in high irradiation environment

  9. Intrinsic densitometry: In-plant evaluation

    International Nuclear Information System (INIS)

    Nishida, K.; Kurosawa, A.; Masui, J.; Hsue, S.T.

    1994-11-01

    A measurement of the plutonium concentration in a sample is always necessary for nuclear material control and accounting. This report describes the testing of the intrinsic densitometry (ID) technique for implant applications. The authors found that the ID method can determine the plutonium concentrations to between 2 and 3% at concentrations of 100 g/l to 200 g/l with quartz cells and a measurement time of 3600 s. The precision can be improved to 1 to 2% with a higher counting rate. The authors also found that nitric acid concentration and the impurity level of uranium in the product plutonium solution do not affect the concentration measurement. When this technique is applied to plutonium solutions in stainless steel pipes, they found that similar precision in plutonium concentration can be achieved using a high-count-rate detector. The precision, however, is reduced with aged plutonium solutions

  10. Measurements of Lα, Lβ X-ray production cross sections of Bi by 17-40 keV electron impact

    International Nuclear Information System (INIS)

    Wu, Y.; An, Z.; Duan, Y.M.; Liu, M.T.

    2010-01-01

    We present results of measurements of L α , L β X-ray production cross sections for the element Bi (Z = 83) by 17-40 keV electron impact. The target used in the experiment was prepared by evaporating the element Bi to the thick pure carbon substrate. The effects of multiple scattering of electrons when penetrating the target film, of electrons reflected from the thick pure carbon substrate and of bremsstrahlung photons produced by the impact of incident electrons on the target are corrected by means of Monte Carlo simulation. The experimental data, reported here for the first time in the energy region of 17-40 keV, are compared with the DWBA theory and the PWBA-C-Ex theory. They are in good agreement.

  11. MODIS/Aqua Clear Radiance Statistics Indexed to Global Grid 5-Min L2 Swath 10km V006

    Data.gov (United States)

    National Aeronautics and Space Administration — The MODIS/Aqua Clear Radiance Statistics Indexed to Global Grid 5-Min L2 Swath 10km (MYDCSR_G) provides a variety of statistical measures that characterize observed...

  12. Magnetic moment of the 9/2[sup +] 96. 4 keV state in [sup 79] Rb

    Energy Technology Data Exchange (ETDEWEB)

    Dumitru, M; Ionescu-Bujor, M; Iordachescu, A; Ivan, A; Ivanov, E A; Pascovici, G; Plostinaru, D [Institute of Atomic Physics, Institute of Physics and Nuclear Engineering, R-76900 Bucharest, P.O.Box MG-6, (Romania)

    1992-01-01

    The region of nuclei with A [approx equal] 80 is presently of considerable interest as it exhibits a rich variety of phenomena. In the present work, part of a programme of structure investigation in this region through electromagnetic moment measurements, we have determined the magnetic moment of the 9/2[sup +] 96.4 keV state in [sup 79] Rb. The state has been excited by the [sup 79] Br ([sup 3] He , 3 n) reaction on a K Br target with cubic structure, using a 30 MeV pulsed beam of [sup 3] He provided by a U-120 cyclotron. The measurements have been performed by the TDPAD method at several different values of the external magnetic field. From our investigations the half-life T[sub 1/2] = 18.5(5) ns and the gyromagnetic ratio g = +1.12(5) have been established for the 9/2[sup +] 96.4 keV state. The band properties of the odd Rb nuclei indicated a gradual change of the structure along the isotopes, the [sup 79] Rb nucleus being characterized by a deformation significantly larger than that of heavier once. This change in structure is also reflected in the g factor values of the low-lying 9/2[sup +] states, which show a monotonic decrease from [sup 85] Rb to [sup 79] Rb. (Author).

  13. Total conversion coefficient of the 263 keV (21/sup 2//2->13/sup +//2) transition in sup(93m)Mo

    Energy Technology Data Exchange (ETDEWEB)

    Suryanaryana, C.; Venkateswara Rao, M.; Narayana, D.G.S.; Bhuloka Reddy, S.; Satyanarayana, G.; Sastry, D.L.; Chintalapudi, S.N.

    1985-01-01

    The total conversion coefficient of the 263 keV gamma transition in the decay scheme of sup(93m)Mo is measured by intensity balance method using a HP Ge spectrometer system. The experimental value of ..cap alpha..sub(T)(263 keV) is found to be 0.696 +- 0.05 which is in agreement with the theoretical values 0.72 and 0.7. The transition probability T(E4) is calculated using the present value of ..cap alpha..sub(T) and compared with the single-particle estimate. A good agreement is noted between the theory and the experiment for the value of T(E4).

  14. PD-L2 Regulates B-1 Cell Antibody Production against Phosphorylcholine through an IL-5-Dependent Mechanism.

    Science.gov (United States)

    McKay, Jerome T; Haro, Marcela A; Daly, Christina A; Yammani, Rama D; Pang, Bing; Swords, W Edward; Haas, Karen M

    2017-09-15

    B-1 cells produce natural Abs which provide an integral first line of defense against pathogens while also performing important homeostatic housekeeping functions. In this study, we demonstrate that programmed cell death 1 ligand 2 (PD-L2) regulates the production of natural Abs against phosphorylcholine (PC). Naive PD-L2-deficient (PD-L2 -/- ) mice produced significantly more PC-reactive IgM and IgA. This afforded PD-L2 -/- mice with selectively enhanced protection against PC-expressing nontypeable Haemophilus influenzae , but not PC-negative nontypeable Haemophilus influenzae , relative to wild-type mice. PD-L2 -/- mice had significantly increased PC-specific CD138 + splenic plasmablasts bearing a B-1a phenotype, and produced PC-reactive Abs largely of the T15 Id. Importantly, PC-reactive B-1 cells expressed PD-L2 and irradiated chimeras demonstrated that B cell-intrinsic PD-L2 expression regulated PC-specific Ab production. In addition to increased PC-specific IgM, naive PD-L2 -/- mice and irradiated chimeras reconstituted with PD-L2 -/- B cells had significantly higher levels of IL-5, a potent stimulator of B-1 cell Ab production. PD-L2 mAb blockade of wild-type B-1 cells in culture significantly increased CD138 and Blimp1 expression and PC-specific IgM, but did not affect proliferation. PD-L2 mAb blockade significantly increased IL-5 + T cells in culture. Both IL-5 neutralization and STAT5 inhibition blunted the effects of PD-L2 mAb blockade on B-1 cells. Thus, B-1 cell-intrinsic PD-L2 expression inhibits IL-5 production by T cells and thereby limits natural Ab production by B-1 cells. These findings have broad implications for the development of therapeutic strategies aimed at altering natural Ab levels critical for protection against infectious disease, autoimmunity, allergy, cancer, and atherosclerosis. Copyright © 2017 by The American Association of Immunologists, Inc.

  15. Purification, crystallization and preliminary X-ray diffraction study of human ribosomal protein L10 core domain

    International Nuclear Information System (INIS)

    Nishimura, Mitsuhiro; Kaminishi, Tatsuya; Kawazoe, Masahito; Shirouzu, Mikako; Takemoto, Chie; Yokoyama, Shigeyuki; Tanaka, Akiko; Sugano, Sumio; Yoshida, Takuya; Ohkubo, Tadayasu; Kobayashi, Yuji

    2007-01-01

    A truncated variant of human ribosomal protien L10 was prepared and crystallized. Diffraction data were collected to 2.5 Å resolution. Eukaryotic ribosomal protein L10 is an essential component of the large ribosomal subunit, which organizes the architecture of the aminoacyl-tRNA binding site. The human L10 protein is also called the QM protein and consists of 214 amino-acid residues. For crystallization, the L10 core domain (L10CD, Phe34–Glu182) was recombinantly expressed in Escherichia coli and purified to homogeneity. A hexagonal crystal of L10CD was obtained by the sitting-drop vapour-diffusion method. The L10CD crystal diffracted to 2.5 Å resolution and belongs to space group P3 1 21 or P3 2 21

  16. Versatility of {l_brace}M(30-crown-10){r_brace} (M = K{sup +}, Ba{sup 2+}) as a guest in UO{sub 2}{sup 2+} complexes of 3.1.3.1 - and 3.3.3 homo-oxa-calixarenes

    Energy Technology Data Exchange (ETDEWEB)

    Masci, B. [Univ Roma La Sapienza, Dipartimento Chim, I-00185 Rome, (Italy); Thuery, P. [CEA Saclay, DSM/DRECAM/SCM, CNRS-URA 331, F-91191 Gif Sur Yvette, (France)

    2007-07-01

    The reaction between p-R-[3.1.3.1]- or [3.3.3] homo-oxa-calixarenes and uranyl salts in the presence of 30-crown-10 and the alkali or alkaline-earth metal cations K{sup +} or Ba{sup 2+} gives various supramolecular assemblages characterized by 'complex-within-complex' architectures. These can be of the simple nesting or sandwich types, as in [{l_brace}Ba(30-crown-10){r_brace}{l_brace}UO{sub 2}(L{sup 1}){r_brace}]. 2H{sub 2}O.3CHCl{sub 3} (L{sup 1}H{sub 4} p-tert-butyl[3.1.3.1] homo-oxa-calixarene) and [{l_brace}Ba(30-crown-10){r_brace}{l_brace}UO{sub 2}(L{sup 4}){r_brace}{sub 2}].2CHCl{sub 3} (L{sup 4}H{sub 3} p-bromo[3.3.3]homo-oxa-calixarene), respectively, with the cation held in the cavity of the homo-oxa-calixarene complexes in cone conformation by weak interactions, but more original structures arise when uranyl-cation bonds are present. In [{l_brace}Ba(30-crown-10){r_brace}{l_brace}UO{sub 2}(L{sup 2}){r_brace}] (L{sup 2}H{sub 4} p-phenyl[3.1.3.1] homo-oxa-calixarene), the barium ion included in the crown ether is bound to the uranyl oxo group located out of the calixarene cavity, resulting in the formation of a neutral species which self-organizes to form a columnar assembly by auto-inclusion. In [{l_brace}K(30-crown-10){r_brace}{l_brace}UO{sub 2}K(L{sup 1})(H{sub 2}O){sub 3}{r_brace}]{sub 2}.6H{sub 2}O, the nesting-type subunit dimerizes around two oxo-bound potassium ions. Finally, the use of the coordinating solvent dimethylsulfoxide leads to the neutral complex [UO{sub 2}Ba(L{sup 3})(dmso){sub 2}(MeOH)]{sub 2} (L{sup 3}H{sub 4} = p-methyl[3.1.3.1] homo-oxa-calixarene), in which the crown ether is absent and two oxo-, phenoxo- and ether-bound barium atoms ensure the dimerization of the uranyl complex. (authors)

  17. Transition from L mode to high ion temperature mode in CHS heliotron/torsatron plasmas

    International Nuclear Information System (INIS)

    Ida, K.; Osakabe, M.; Tanaka, K.

    2001-01-01

    A high ion temperature mode (high T i mode) is observed for neutral beam heated plasmas in the Compact Helical System (CHS) Heliotron/torsatron. The high T i mode plasma is characterized by a high central ion temperature, T i (0), and is associated with a peaked electron density profile produced by neutral beam fueling with low wall recycling. Transition from L mode to high T i mode has been studied in CHS. The central ion temperature in the high T i mode discharges reaches to 1 keV which is 2.5 times higher than that in the L mode discharges. The ion thermal diffusivity is significantly reduced by a factor of more than 2-3 in the high T i mode plasma. The ion loss cone is observed in neutral particle flux in the energy range of 1-6 keV with a narrow range of pitch angle (90±10 degree) in the high T i mode. However, the degradation of ion energy confinement due to this loss cone is negligible. (author)

  18. Intrinsic Rotation and Momentum Transport in Reversed Shear Plasmas with Internal Transport Barriers

    Science.gov (United States)

    Jhang, Hogun; Kim, S. S.; Diamond, P. H.

    2010-11-01

    The intrinsic rotation in fusion plasmas is believed to be generated via the residual stress without external momentum input. The physical mechanism responsible for the generation and transport of intrinsic rotation in L- and H-mode tokamak plasmas has been studied extensively. However, it is noted that the physics of intrinsic rotation generation and its relationship to the formation of internal transport barriers (ITBs) in reversed shear (RS) tokamak plasmas have not been explored in detail, which is the main subject in the present work. A global gyrofluid code TRB is used for this study. It is found that the large intrinsic rotation (˜10-30% of the ion sound speed depending on ITB characteristics) is generated near the ITB region and propagates into the core. The intrinsic rotation increases linearly as the temperature gradient at ITB position increases, albeit not indefinitely. Key parameters related to the symmetry breaking, such as turbulent intensity and its gradient, the flux surface averaged parallel wavenumber are evaluated dynamically during the ITB formation. The role of reversed shear and the q-profile curvature is presented in relation to the symmetry breaking mechanism in RS plasmas.

  19. Absolute M1 and E2 Transition Probabilities in 2{sup 33}U

    Energy Technology Data Exchange (ETDEWEB)

    Malmskog, S G; Hoejeberg, M

    1967-08-15

    Using the delayed coincidence technique, the following half lives have been determined for different excited states in {sup 233}U: T{sub 1/2} (311.9 keV level) = (1.20 {+-} 0.15) x 10{sup -10} sec, T{sub 1/2} (340.5 keV level) = (5.2 {+-} 1.0) x 10{sup -11} sec, T{sub 1/2} (398.6 keV level) = (5.5 {+-} 2.0) x 10{sup -11} sec and T{sub 1/2} (415.8 keV level) < 3 x 10{sup -11}sec. From these half life determinations, together with earlier known electron intensities and conversion coefficients, 22 reduced B(Ml) and B(E2) transition probabilities (including 9 limits) have been deduced. The rotational transitions give information on the parameters {delta} and (g{sub K} - g{sub R}) . The experimental M1 and E2 transition rates between members of different bands have been analysed in terms of the predictions of the Nilsson model, taking also pairing correlations and Coriolis coupling effects into account.

  20. Electron Flux Dropouts at L ˜ 4.2 From Global Positioning System Satellites: Occurrences, Magnitudes, and Main Driving Factors

    Science.gov (United States)

    Boynton, R. J.; Mourenas, D.; Balikhin, M. A.

    2017-11-01

    Dropouts in electron fluxes at L ˜ 4.2 were investigated for a broad range of energies from 120 keV to 10 MeV, using 16 years of electron flux data from Combined X-ray Dosimeter on board Global Positioning System (GPS) satellites. Dropouts were defined as flux decreases by at least a factor 4 in 12 h, or 24 h during which a decrease by at least a factor of 1.5 must occur during each 12 h time bin. Such fast and strong dropouts were automatically identified from the GPS electron flux data and statistics of dropout magnitudes, and occurrences were compiled as a function of electron energy. Moreover, the Error Reduction Ratio analysis was employed to search for nonlinear relationships between electron flux dropouts and various solar wind and geomagnetic activity indices, in order to identify potential external causes of dropouts. At L ˜ 4.2, the main driving factor for the more numerous and stronger 1-10 MeV electron dropouts turns out to be the southward interplanetary magnetic field Bs, suggesting an important effect from precipitation loss due to combined electromagnetic ion cyclotron and whistler mode waves in a significant fraction of these events, supplementing magnetopause shadowing and outward radial diffusion which are also effective at lower energies.

  1. Intrinsic fluctuations in sub 10-nm double-gate MOSFETs introduced by discreteness of charge and matter

    OpenAIRE

    Brown, A.R.; Asenov, A.; Watling, J.R.

    2002-01-01

    We study, using numerical simulation, the intrinsic parameter fluctuations in sub 10 nm gate length double gate MOSFETs introduced by discreteness of charge and atomicity of matter. The employed "atomistic" drift-diffusion simulation approach includes quantum corrections based on the density gradient formalism. The quantum confinement and source-to-drain tunnelling effects are carefully calibrated in respect of self-consistent Poisson-Schrodinger and nonequilibrium Green's function simulation...

  2. Fragmentation of anthracene induced by collisions with 40 keV Ar8+ ions

    International Nuclear Information System (INIS)

    Brédy, R; Ortéga, C; Ji, M; Bernard, J; Chen, L; Montagne, G; Martin, S

    2013-01-01

    We report on the fragmentation of anthracene molecular ions C 14 H 10 r+ as a function of the parent ion initial charge r (= 1–4). Neutral anthracene molecules in the gas phase were ionized and excited in collisions with Ar 8+ ions at 40 keV and the mass-to-charge spectra of the parent ions C 14 H 10 r+ (1 ⩽ r ⩽ 4) were obtained. Stable molecular ions C 14 H 10 r+ (1 ⩽ r ⩽ 3) are observed. Branching ratios for the competitive evaporation (loss of neutral fragments) and fragmentation (charge separation) processes were measured for C 14 H 10 2+ parent ions. For C 14 H 10 3+ parent ions, the results indicate that fragmentation is the only dominant process and quasi-symmetric fission is observed. (paper)

  3. Intrinsic uncoupling of mitochondrial proton pumps. 2. Modeling studies.

    Science.gov (United States)

    Pietrobon, D; Zoratti, M; Azzone, G F; Caplan, S R

    1986-02-25

    The thermodynamic and kinetic properties associated with intrinsic uncoupling in a six-state model of a redox proton pump have been studied by computing the flow-force relations for different degrees of coupling. Analysis of these relations shows the regulatory influence of the thermodynamic forces on the extent and relative contributions of redox slip and proton slip. Inhibition has been introduced into the model in two different ways, corresponding to possible modes of action of experimental inhibitors. Experiments relating the rate of electron transfer to delta microH at static head upon progressive inhibition of the pumps have been simulated considering (1) the limiting case that the nonzero rate of electron transfer at static head is only due to intrinsic uncoupling (no leaks) and (2) the experimentally observed case that about 30% of the nonzero rate of electron transfer at static head is due to a constant proton leakage conductance in parallel with the pumps, the rest being due to intrinsic uncoupling. The same simulations have been performed for experiments in which the rate of electron transfer is varied by varying the substrate concentration rather than by using an inhibitor. The corresponding experimental results obtained by measuring delta microH and the rate of electron transfer at different succinate concentrations in rat liver mitochondria are presented. Comparison between simulated behavior and experimental results leads to the general conclusion that the typical relationship between rate of electron transfer and delta microH found in mitochondria at static head could certainly be a manifestation of some degree of intrinsic uncoupling in the redox proton pumps.(ABSTRACT TRUNCATED AT 250 WORDS)

  4. Studies of internal bremsstrahlung spectrum of 35S beta emitter in the photon energy region of 1–100 keV

    International Nuclear Information System (INIS)

    Singh, Amrit; Dhaliwal, A.S.

    2014-01-01

    The internal bremsstrahlung (IB) spectral photon distribution, produced by soft beta particles of 35 S (W max =164 keV), in the photon energy region of 1–100 keV, is measured by using a Si(Li) detector, having high energy resolution and efficiency at low energy region. The measured spectral IB photon distribution is compared with KUB theory and Coulomb corrected IB theories given by Nilsson, and Lewis and Ford. After applying the necessary corrections, the experimental and theoretical IB spectral photon distributions are compared in terms of the number of IB photon of energy k per m o c 2 per unit photon yield. In the low energy region (below 10 keV), the experimental results are in agreement with all the theories. However, in photon energy region of 10–50 keV, experimental results are in agreement with Coulomb corrected Nilsson theory only, within the experimental errors. Further, beyond 50 keV, the Nilsson theory is more close to the experimental results than the KUB, and the Lewis and Ford theories. Hence, the Nilsson theory is more accurate than the other theories given by KUB and Lewis and Ford, particularly at a high energy end. The experimental results reported here with Si(Li) detector are free from number of ambiguities in earlier measurements reported with NaI(Tl) and HPGe detectors. The present results are indicating a relook into the theoretical considerations, given by different theories, while taking into account the Coulomb corrections for predicting the IB spectrum, particularly at high photon energy region. - Highlights: • The internal bremsstrahlung spectrum of 35 S beta emitter, in the photon energy region of 1–100 keV. • These measurement are taken by using a Si(Li) detector. • Theoretical and experimental results are reported in terms of number of photons of energy k per m 0 c 2 per unit photon yield. • The Nilsson theory for IB is more accurate than KUB and Lewis and Ford, particularly at high photon energy region

  5. Characteristics of > 290 keV magnetosheath ions

    Directory of Open Access Journals (Sweden)

    A. Rigas

    Full Text Available We performed a statistical analysis of 290-500 keV ion data obtained by IMP-8 during the years 1982-1988 within the earth's magnetosheath and analysed in detail some time periods withdistinct ion bursts. These studies reveal the following characteristics for magnetosheath 290-500 keV energetic ions: (a the occurrence frequency and the flux of ions increase with increasing geomagnetic activity as indicated by the Kp index; the occurrence frequency was found to be as high as P > 42% for Kp > 2, (b the occurrence frequency in the dusk magnetosheath was found to be slightly dependent on the local time and ranged between ~30% and ~46% for all Kp values; the highest occurrence frequency was detected near the dusk magnetopause (21 LT, (c the high energy ion bursts display a dawn-dusk asymmetry in their maximum fluxes, with higher fluxes appearing in the dusk magnetosheath, and (d the observations in the dusk magnetosheath suggest that there exist intensity gradients of energetic ions from the bow shock toward the magnetopause. The statistical results are consistent with the concept that leakage of magnetospheric ions from the dusk magnetopause is a semi-permanent physical process often providing the magnetosheath with high energy (290-500 keV ions.Key words. Magnetospheric physics (magnetosheath; planetary magnetospheres. Space plasma physics (shock waves.

  6. Decay /sup 133/Ba

    Energy Technology Data Exchange (ETDEWEB)

    Singh, K; Hasiza, M L; Grewal, B S; Sahota, H S

    1982-07-01

    The relative gamma ray intensities of transitions in the decay of /sup 133/Ba have been measured using an intrinsic Ge detector. The electron capture branching ratios have been determined for 81, 161, 384 and 437 keV levels. The attenuation effect of long half-life of 81 keV levels has been studied in solid and liquid media. The electron capture decay has been investigated by changing the concentration of ethylene-diamine-tetraacetic acid (EDTA) environment. The 5/2/sup +/ yields 5/2/sup +/ 79.67 keV transition has an E0 to E2 intensity qsub(k)sup(2) <= 0.31. 10 refs., 4 figures.

  7. Effect of irradiation with <200 keV electrons on AG-80 resin

    Energy Technology Data Exchange (ETDEWEB)

    Gao Yu [School of Materials Science and Engineering, Harbin Institute of Technology, 432 Heilongjiang province, Harbin 150001 (China)]. E-mail: czq04@yahoo.com.cn; Jiang Shengling [College of Materials Science and Engineering, Beijing University of Chemical Technology, Beijing 100029 (China); Sun Mingren [School of Materials Science and Engineering, Harbin Institute of Technology, 432 Heilongjiang province, Harbin 150001 (China); Yang Dezhuang [School of Materials Science and Engineering, Harbin Institute of Technology, 432 Heilongjiang province, Harbin 150001 (China); He Shiyu[School of Materials Science and Engineering, Harbin Institute of Technology, 432 Heilongjiang province, Harbin 150001 (China); Li Zhijun [39th Institute, China Electronic Science and Technology Groups Inc., Xi-an 710065 (China)

    2005-08-01

    AG-80 resin, namely tetraglycidyl diaminodiphenyl methane (TGDDM), is a new type of thermosetting matrix for advanced carbon/epoxy composites, which was irradiated with electrons of 160 keV. The results show that by increasing the fluence to 6.3x10{sup 15} cm{sup -2}, the mass loss ratio ascends dramatically and then tends to level off. The mass loss behavior can be attributed to the combined effects of the formation of gaseous radiolytic products and a degraded layer, the surface ablation due to discharging and the skin carbon enrichment.

  8. 56Fe resonance parameters for neutron energies up to 850 keV

    International Nuclear Information System (INIS)

    Perey, C.M.; Perey, F.G.; Harvey, J.A.; Hill, N.W.; Larson, N.M.

    1990-12-01

    High-resolution neutron measurements for 56 Fe-enriched iron targets were made at the Oak Ridge Electron Linear Accelerator (ORELA) in transmission below 20 MeV and in differential elastic scattering below 5 MeV. Transmission measurements were also performed with a natural iron target below 160 keV. The transmission data were analyzed from 5 to 850 keV with the multilevel R-matrix code SAMMY which uses Bayes' theorem for the fitting process. This code provides energies and neutron widths of the resonances inside the 5- to 850-keV energy region, as well as possible parameterization for resonances external to the analyzed region to describe the smooth cross section from a few eV to 850 keV. The resulting set of resonance parameters yields the accepted values for the thermal total and capture cross sections. The differential elastic-scattering data at several scattering angles were compared to theoretical calculations from 40 to 850 keV using the R-matrix code RFUNC based on the Blatt-Biedenharn formalism. Various combinations of spin and parity were tried to predict cross sections for the well defined ell > 0 resonances; comparison of these predictions with the data allowed us to determine the most likely spin and parity assignments for these resonances. The results of a capture data analysis by Corvi et al. (COR84), from 2 to 350 keV, were combined with our results to obtain the radiation widths of the resonances below 350 keV observed in transmission, capture, and differential elastic-scattering experiments

  9. Intrinsic and Extrinsic Motivation, Orientation and Achievements in L2 of Arab Learners of English, French and German: A Study from Jordan

    Science.gov (United States)

    Kreishan, Lana J.; Al-Dhaimat, Yahya

    2013-01-01

    The aim of this research is to explore Jordanian undergraduate students' intrinsic and extrinsic motivations and instrumental and integrative orientations toward learning English, French, and German as foreign languages. The paper also reflects on how subtypes of intrinsic and extrinsic motivations relate to orientations and examines possible…

  10. Cosmological information in the intrinsic alignments of luminous red galaxies

    Energy Technology Data Exchange (ETDEWEB)

    Chisari, Nora Elisa [Department of Astrophysical Sciences, Princeton University, 4 Ivy Lane, Princeton, NJ 08544 (United States); Dvorkin, Cora, E-mail: nchisari@astro.princeton.edu, E-mail: cdvorkin@ias.edu [Institute for Advanced Study, School of Natural Sciences, Einstein Drive, Princeton, NJ 08540 (United States)

    2013-12-01

    The intrinsic alignments of galaxies are usually regarded as a contaminant to weak gravitational lensing observables. The alignment of Luminous Red Galaxies, detected unambiguously in observations from the Sloan Digital Sky Survey, can be reproduced by the linear tidal alignment model of Catelan, Kamionkowski and Blandford (2001) on large scales. In this work, we explore the cosmological information encoded in the intrinsic alignments of red galaxies. We make forecasts for the ability of current and future spectroscopic surveys to constrain local primordial non-Gaussianity and Baryon Acoustic Oscillations (BAO) in the cross-correlation function of intrinsic alignments and the galaxy density field. For the Baryon Oscillation Spectroscopic Survey, we find that the BAO signal in the intrinsic alignments is marginally significant with a signal-to-noise ratio of 1.8 and 2.2 with the current LOWZ and CMASS samples of galaxies, respectively, and increasing to 2.3 and 2.7 once the survey is completed. For the Dark Energy Spectroscopic Instrument and for a spectroscopic survey following the EUCLID redshift selection function, we find signal-to-noise ratios of 12 and 15, respectively. Local type primordial non-Gaussianity, parametrized by f{sub NL} = 10, is only marginally significant in the intrinsic alignments signal with signal-to-noise ratios < 2 for the three surveys considered.

  11. Fluence to absorbed foetal dose conversion coefficients for photons in 50 keV-10 GeV calculated using RPI-P models

    International Nuclear Information System (INIS)

    Taranenko, V.; Xu, X.G.

    2008-01-01

    Radiation protection of pregnant females and the foetus against ionising radiation is of particular importance to radiation protection due to high foetal radiosensitivity. The only available set of foetal conversion coefficients for photons is based on stylised models of simplified anatomy. Using the RPI-P series of pregnant female and foetus models representing 3-, 6- and 9-month gestation, a set of new fluence to absorbed foetal dose conversion coefficients has been calculated. The RPI-P anatomical models were developed using novel 3D geometry modelling techniques. Organ masses were adjusted to agree within 1% with the ICRP reference data for a pregnant female. Monte Carlo dose calculations were carried out using the MCNPX and Penelope codes for external 50 keV-10 GeV photon beams of six standard configurations. The models were voxelised at 3-mm voxel resolution. Conversion coefficients were tabulated for the three gestational periods for the whole foetus and brain. Comparison with previously published data showed deviations up to 120% for the foetal doses at 50 keV. The discrepancy can be primarily ascribed to anatomical differences. Comparison with published data for five major mother organs is also provided for the 3-month model. Since the RPI-P models exhibit a high degree of anatomical realism, the reported dataset is recommended as a reference for radiation protection of the foetus against external photon exposure. (authors)

  12. L2, the minor capsid protein of papillomavirus

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Joshua W. [Department of Pathology, The Johns Hopkins University, Baltimore, MD 21287 (United States); Roden, Richard B.S., E-mail: roden@jhmi.edu [Department of Pathology, The Johns Hopkins University, Baltimore, MD 21287 (United States); Department of Oncology, The Johns Hopkins University, Baltimore, MD 21287 (United States); Department of Gynecology and Obstetrics, The Johns Hopkins University, Baltimore, MD 21287 (United States)

    2013-10-15

    The capsid protein L2 plays major roles in both papillomavirus assembly and the infectious process. While L1 forms the majority of the capsid and can self-assemble into empty virus-like particles (VLPs), L2 is a minor capsid component and lacks the capacity to form VLPs. However, L2 co-assembles with L1 into VLPs, enhancing their assembly. L2 also facilitates encapsidation of the ∼8 kbp circular and nucleosome-bound viral genome during assembly of the non-enveloped T=7d virions in the nucleus of terminally differentiated epithelial cells, although, like L1, L2 is not detectably expressed in infected basal cells. With respect to infection, L2 is not required for particles to bind to and enter cells. However L2 must be cleaved by furin for endosome escape. L2 then travels with the viral genome to the nucleus, wherein it accumulates at ND-10 domains. Here, we provide an overview of the biology of L2. - Highlights: • L2 is the minor antigen of the non-enveloped T=7d icosahedral Papillomavirus capsid. • L2 is a nuclear protein that can traffic to ND-10 and facilitate genome encapsidation. • L2 is critical for infection and must be cleaved by furin. • L2 is a broadly protective vaccine antigen recognized by neutralizing antibodies.

  13. L2, the minor capsid protein of papillomavirus

    International Nuclear Information System (INIS)

    Wang, Joshua W.; Roden, Richard B.S.

    2013-01-01

    The capsid protein L2 plays major roles in both papillomavirus assembly and the infectious process. While L1 forms the majority of the capsid and can self-assemble into empty virus-like particles (VLPs), L2 is a minor capsid component and lacks the capacity to form VLPs. However, L2 co-assembles with L1 into VLPs, enhancing their assembly. L2 also facilitates encapsidation of the ∼8 kbp circular and nucleosome-bound viral genome during assembly of the non-enveloped T=7d virions in the nucleus of terminally differentiated epithelial cells, although, like L1, L2 is not detectably expressed in infected basal cells. With respect to infection, L2 is not required for particles to bind to and enter cells. However L2 must be cleaved by furin for endosome escape. L2 then travels with the viral genome to the nucleus, wherein it accumulates at ND-10 domains. Here, we provide an overview of the biology of L2. - Highlights: • L2 is the minor antigen of the non-enveloped T=7d icosahedral Papillomavirus capsid. • L2 is a nuclear protein that can traffic to ND-10 and facilitate genome encapsidation. • L2 is critical for infection and must be cleaved by furin. • L2 is a broadly protective vaccine antigen recognized by neutralizing antibodies

  14. Efficient focusing of 8 keV X-rays with multilayer Fresnel zone plates fabricated by atomic layer deposition and focused ion beam milling

    International Nuclear Information System (INIS)

    Mayer, Marcel; Keskinbora, Kahraman; Grévent, Corinne; Szeghalmi, Adriana; Knez, Mato; Weigand, Markus; Snigirev, Anatoly; Snigireva, Irina; Schütz, Gisela

    2013-01-01

    The fabrication and performance of multilayer Al 2 O 3 /Ta 2 O 5 Fresnel zone plates in the hard X-ray range and a discussion of possible future developments considering available materials are reported. Fresnel zone plates (FZPs) recently showed significant improvement by focusing soft X-rays down to ∼10 nm. In contrast to soft X-rays, generally a very high aspect ratio FZP is needed for efficient focusing of hard X-rays. Therefore, FZPs had limited success in the hard X-ray range owing to difficulties of manufacturing high-aspect-ratio zone plates using conventional techniques. Here, employing a method of fabrication based on atomic layer deposition (ALD) and focused ion beam (FIB) milling, FZPs with very high aspect ratios were prepared. Such multilayer FZPs with outermost zone widths of 10 and 35 nm and aspect ratios of up to 243 were tested for their focusing properties at 8 keV and shown to focus hard X-rays efficiently. This success was enabled by the outstanding layer quality thanks to ALD. Via the use of FIB for slicing the multilayer structures, desired aspect ratios could be obtained by precisely controlling the thickness. Experimental diffraction efficiencies of multilayer FZPs fabricated via this combination reached up to 15.58% at 8 keV. In addition, scanning transmission X-ray microscopy experiments at 1.5 keV were carried out using one of the multilayer FZPs and resolved a 60 nm feature size. Finally, the prospective of different material combinations with various outermost zone widths at 8 and 17 keV is discussed in the light of the coupled wave theory and the thin-grating approximation. Al 2 O 3 /Ir is outlined as a promising future material candidate for extremely high resolution with a theoretical efficiency of more than 20% for as small an outermost zone width as 10 nm at 17 keV

  15. Hypothyroid Patients Encoding Combined MCT10 and DIO2 Gene Polymorphisms May Prefer L-T3 + L-T4 Combination Treatment - Data Using a Blind, Randomized, Clinical Study

    DEFF Research Database (Denmark)

    Carlé, Allan; Faber, Jens; Steffensen, Rudi

    2017-01-01

    on the cellular membrane transport-facilitating monocarboxylate transporter (MCT10) gene (rs17606253), and asked in which of the 2 treatment periods patients felt better (i.e., which treatment was preferred). RESULTS: 27 out of 45 patients (60%) preferred the combination therapy. Two polymorphisms (rs225014 (DIO2......, Thr92Ala) and rs17606253 (MCT10)) were combined yielding 3 groups: none vs. 1 of 2 vs. both SNPs present, and 42 vs. 63 vs. 100% of our patients in the 3 groups preferred the combined treatment (Jongheere-Terpstra trend test, p = 0.009). CONCLUSION: The present study indicates that the combination...... of polymorphisms in DIO2 (rs225014) and MCT10 (rs17606253) enhances hypothyroid patients' preference for L-T4 + L-T3 replacement therapy. In the future, combination therapy may be restricted or may be even recommended to individuals harbouring certain polymorphisms....

  16. Generation mechanism of L-value dependence of oxygen flux enhancements during substorms

    Science.gov (United States)

    Nakayama, Y.; Ebihara, Y.; Tanaka, T.; Ohtani, S.; Gkioulidou, M.; Takahashi, K.; Kistler, L. M.; Kletzing, C.

    2015-12-01

    The Van Allen Probes Helium Oxygen Proton Electron (HOPE) instrument measures charged particles with an energy range from ~eV to ~ tens of keV. The observation shows that the energy flux of the particles increases inside the geosynchronous orbit during substorms. For some night-side events around the apogee, the energy flux of O+ ion enhances below ~10 keV at lower L shell, whereas the flux below ~8 keV sharply decreases at higher L shells. This structure of L-energy spectrogram of flux is observed only for the O+ ions. The purpose of this study is to investigate the generation mechanism of the structure by using numerical simulations. We utilized the global MHD simulation developed by Tanaka et al (2010, JGR) to simulate the electric and magnetic fields during substorms. We performed test particle simulation under the electric and magnetic fields by applying the same model introduced by Nakayama et al. (2015, JGR). In the test particle simulation each test particle carries the real number of particles in accordance with the Liouville theorem. Using the real number of particles, we reconstructed 6-dimensional phase space density and differential flux of O+ ions in the inner magnetosphere. We obtained the following results. (1) Just after the substorm onset, the dawn-to-dusk electric field is enhanced to ~ 20 mV/m in the night side tail region at L > 7. (2) The O+ ions are accelerated and transported to the inner region (L > ~5.5) by the large-amplitude electric field. (3) The reconstructed L-energy spectrogram shows a similar structure to the Van Allen Probes observation. (4) The difference in the flux enhancement between at lower L shell and higher L shells is due to two distinct acceleration processes: adiabatic and non-adiabatic. We will discuss the relationship between the particle acceleration and the structure of L-energy spectrogram of flux enhancement in detail.

  17. Differential cross sections for single ionization of H2 by 75keV proton impact

    International Nuclear Information System (INIS)

    Chowdhury, U; Schulz, M; Madison, D H

    2012-01-01

    We have calculated Triply differential cross sections (TDCS) and doubly differential cross sections (DDCS) for single ionization of H 2 by 75 keV proton impact using the molecular 3 body distorted wave Eikonal initial state (M3DW-EIS) approach. Previously published measured DDCS-P (differential in the projectile scattering angle and integrated over the ejected electron angles) found pronounced structures at relatively large angles which were interpreted as an interference resulting from the two-centered potential of the molecule.

  18. Broadband X-Ray Spectral Analysis of the Double-nucleus Luminous Infrared Galaxy Mrk 463

    Science.gov (United States)

    Yamada, Satoshi; Ueda, Yoshihiro; Oda, Saeko; Tanimoto, Atsushi; Imanishi, Masatoshi; Terashima, Yuichi; Ricci, Claudio

    2018-05-01

    We present a broadband (0.4–70 keV) X-ray spectral analysis of the luminous infrared galaxy (LIRG) system Mrk 463 observed with Nuclear Spectroscopic Telescope Array (NuSTAR), Chandra, and XMM-Newton, which contains double active galactic nuclei (AGNs; Mrk 463E and Mrk 463W) with a separation of ∼3.8 kpc. Detecting their transmitted hard X-ray >10 keV continua with NuSTAR, we confirm that Mrk 463E and Mrk 463W have AGNs with intrinsic luminosities of (1.6–2.2) × 1043 and (0.5–0.6) × 1043 erg s‑1 (210 keV) obscured by hydrogen column densities of 8 × 1023 and 3 × 1023 cm‑2, respectively. Both nuclei show strong reflection components from cold matter. The luminosity ratio between X-ray (210 keV) and [O IV] 25.89 μm of Mrk 463E is ∼5 times smaller than those of normal Seyfert galaxies, suggesting that the intrinsic SED is X-ray weak relative to the UV luminosity. In fact, the bolometric AGN luminosity of Mrk 463E estimated from L‧-band (3.8 μm), [O IV] 25.89 μm, and [Ne V] 14.32 μm lines indicate a large bolometric-to-X-ray luminosity ratio, κ 210 keV ≈ 110–410, and a high Eddington ratio, λ Edd ∼ 0.4–0.8. We suggest that the merger triggered a rapid growth of the black hole in Mrk 463E, which is not yet deeply “buried” by circumnuclear dust. By contrast, the L‧-band luminosity of Mrk 463W is unusually small relative to the X-ray luminosity, suggesting that the Eddington ratio is low (activity.

  19. Octupole deformation in 226Th

    International Nuclear Information System (INIS)

    Liang, C.F.; Paris, P.; Sheline, R.K.

    1999-01-01

    Sources of 230 U - resulting from the β - decay of 230 Pa produced in the reaction 232 Th(p,3n) with 34 MeV protons - were purified and used to determine the half life of the 230.4 keV 1 - state in 226 Th. Using the Doppler shift method, following α decay of 230 U, a value T 1/2 = 3.5 ± 1.2 ps was determined. The half life of the 226.4 keV 4 + state was also measured as T 1/2 = 145 ± 20 ps. The absolute probabilities in Weisskopf units of the 230 keV and 158 keV γ transitions depopulating the 1 - state were determined as (2.50 ± 0.86) x 10 -3 and (4.54 ± 1.55) x 10 -3 respectively. Experimental values of the intrinsic dipole moment, D 0 , and of D 0 /Q 0 , were determined as 0.27 ± 0.05 e.fm and (3.5 ± 1.0) x 10 -4 fm -1 . These data have been compared with theories and experiment. (authors)

  20. Investigation of the effective atomic numbers of dosimetric materials for electrons, protons and alpha particles using a direct method in the energy region 10 keV-1 GeV: a comparative study.

    Science.gov (United States)

    Kurudirek, Murat; Aksakal, Oğuz; Akkuş, Tuba

    2015-11-01

    A direct method has been used for the first time, to compute effective atomic numbers (Z eff) of water, air, human tissues, and some organic and inorganic compounds, for total electron proton and alpha particle interaction in the energy region 10 keV-1 GeV. The obtained values for Z eff were then compared to those obtained using an interpolation procedure. In general, good agreement has been observed for electrons, and the difference (%) in Z eff between the results of the direct and the interpolation method was found to be energy range from 10 keV to 1 MeV. More specifically, results of the two methods were found to agree well (Dif. energy region with respect to the total electron interaction. On the other hand, values for Z eff calculated using both methods for protons and alpha particles generally agree with each other in the high-energy region above 10 MeV.

  1. ON THE SPECTRAL HARDENING AT ∼>300 keV IN SOLAR FLARES

    International Nuclear Information System (INIS)

    Li, G.; Kong, X.; Zank, G.; Chen, Y.

    2013-01-01

    It has long been noted that the spectra of observed continuum emissions in many solar flares are consistent with double power laws with a hardening at energies ∼>300 keV. It is now widely believed that at least in electron-dominated events, the hardening in the photon spectrum reflects an intrinsic hardening in the source electron spectrum. In this paper, we point out that a power-law spectrum of electrons with a hardening at high energies can be explained by the diffusive shock acceleration of electrons at a termination shock with a finite width. Our suggestion is based on an early analytical work by Drury et al., where the steady-state transport equation at a shock with a tanh profile was solved for a p-independent diffusion coefficient. Numerical simulations with a p-dependent diffusion coefficient show hardenings in the accelerated electron spectrum that are comparable with observations. One necessary condition for our proposed scenario to work is that high-energy electrons resonate with the inertial range of the MHD turbulence and low-energy electrons resonate with the dissipation range of the MHD turbulence at the acceleration site, and the spectrum of the dissipation range ∼k –2.7 . A ∼k –2.7 dissipation range spectrum is consistent with recent solar wind observations.

  2. Conversion of the 42 keV transition in the decay of 191Os

    International Nuclear Information System (INIS)

    Bhuloka Reddy, S.; Narasimham, K.L.; Thirumala Rao, B.V.; Lakshminarayana, V.

    1986-01-01

    The total as well as the L-conversion coefficient of the 42 KeV transition in the decay of 191 Os are determined from intensity balance considerations and XPG technique, respectively, using a 3 mm Si(Li) detector system. The resultant values are αsub(T) = 13709 (1900), αsub(L) = 11700 (2100). The present total conversion coefficients shows good agreement within the uncertainty limits, with the value αsub(T) = 13.500→ 5200 +21100 reported by Lange, whereas the L-conversion coefficient is reported for the first time. Our present values are also compared with the theoretical values interpolated from the tables of Hager and Seltzer and of Rosel et al

  3. Intrinsically bent DNA in replication origins and gene promoters.

    Science.gov (United States)

    Gimenes, F; Takeda, K I; Fiorini, A; Gouveia, F S; Fernandez, M A

    2008-06-24

    Intrinsically bent DNA is an alternative conformation of the DNA molecule caused by the presence of dA/dT tracts, 2 to 6 bp long, in a helical turn phase DNA or with multiple intervals of 10 to 11 bp. Other than flexibility, intrinsic bending sites induce DNA curvature in particular chromosome regions such as replication origins and promoters. Intrinsically bent DNA sites are important in initiating DNA replication, and are sometimes found near to regions associated with the nuclear matrix. Many methods have been developed to localize bent sites, for example, circular permutation, computational analysis, and atomic force microscopy. This review discusses intrinsically bent DNA sites associated with replication origins and gene promoter regions in prokaryote and eukaryote cells. We also describe methods for identifying bent DNA sites for circular permutation and computational analysis.

  4. Characteristics of pitch angle distributions of hundreds of keV electrons in the slot region and inner radiation belt

    Science.gov (United States)

    Zhao, H.; Li, X.; Blake, J. B.; Fennell, J. F.; Claudepierre, S. G.; Baker, D. N.; Jaynes, A. N.; Malaspina, D. M.

    2014-12-01

    The pitch angle distribution (PAD) of energetic electrons in the slot region and inner radiation belt received little attention in the past decades due to the lack of quality measurements. Using the state-of-the-art pitch angle-resolved data from the Magnetic Electron Ion Spectrometer instrument onboard the Van Allen Probes, a detailed analysis of hundreds of keV electron PADs below L = 4 is performed, in which the PADs are categorized into three types: normal (flux peaking at 90°), cap (exceedingly peaking narrowly around 90°), and 90° minimum (lower flux at 90°) PADs. By examining the characteristics of the PADs of ˜460 keV electrons for over a year, we find that the 90° minimum PADs are generally present in the inner belt (Lpitch angle scattering of hiss waves. Fitting the normal PADs into sinnα form, the parameter n is much higher below L = 3 than that in the outer belt and relatively constant in the inner belt but changes significantly in the slot region (2 mechanism can hardly explain the formation of 90° minimum PADs at the center of inner belt.

  5. A General Precipitation-limited L X–T–R Relation among Early-type Galaxies

    Science.gov (United States)

    Voit, G. Mark; Ma, C. P.; Greene, J.; Goulding, A.; Pandya, V.; Donahue, M.; Sun, M.

    2018-01-01

    The relation between X-ray luminosity (L X) and ambient gas temperature (T) among massive galactic systems is an important cornerstone of both observational cosmology and galaxy-evolution modeling. In the most massive galaxy clusters, the relation is determined primarily by cosmological structure formation. In less massive systems, it primarily reflects the feedback response to radiative cooling of circumgalactic gas. Here we present a simple but powerful model for the L X–T relation as a function of physical aperture R within which those measurements are made. The model is based on the precipitation framework for AGN feedback and assumes that the circumgalactic medium is precipitation-regulated at small radii and limited by cosmological structure formation at large radii. We compare this model with many different data sets and show that it successfully reproduces the slope and upper envelope of the L X–T–R relation over the temperature range from ∼0.2 keV through ≳ 10 {keV}. Our findings strongly suggest that the feedback mechanisms responsible for regulating star formation in individual massive galaxies have much in common with the precipitation-triggered feedback that appears to regulate galaxy-cluster cores.

  6. Intrinsic strength of sodium borosilicate glass fibers by using a two-point bending technique

    International Nuclear Information System (INIS)

    Nishikubo, Y; Yoshida, S; Sugawara, T; Matsuoka, J

    2011-01-01

    Flaws existing on glass surface can be divided into two types, extrinsic and intrinsic. Although the extrinsic flaws are generated during processing and using, the intrinsic flaws are regarded as structural defects which result from thermal fluctuation. It is known that the extrinsic flaws determine glass strength, but effects of the intrinsic flaws on the glass strength are still unclear. Since it is considered that the averaged bond-strength and the intrinsic flaw would affect the intrinsic strength, the intrinsic strength of glass surely depends on the glass composition. In this study, the intrinsic failure strain of the glass fibers with the compositions of 20Na 2 O-40xB 2 O 3 -(80-40x)SiO 2 (mol%, x = 0, 0.5, 1.0, 1.5) were measured by using a two-point bending technique. The failure strength was estimated from the failure strain and Young's modulus of glass. It is elucidated that two-point bending strength of glass fiber decreases with increasing B 2 O 3 content in glass. The effects of the glass composition on the intrinsic strength are discussed in terms of elastic and inelastic deformation behaviors prior to fracture.

  7. On the 17-keV neutrino

    International Nuclear Information System (INIS)

    Hime, A.

    1993-04-01

    A brief review on the status of the 17-keV neutrino is presented. Several different experiments found spectral distortions which were consistently interpreted as evidence for a heavy neutrino admixture in β decay. Recent experiments, however, rule out the existence of a 17-keV neutrino as well as escaping criticisms of earlier null results. Moreover, the majority of positive results have been reinterpreted in terms of instrumental effects, despite the need for a different explanation in each case. Anomalies persist in the low energy region of the tritium spectrum which deserve further investigation

  8. V2O5 nanowires with an intrinsic peroxidase-like activity

    NARCIS (Netherlands)

    André, R.; Natálio, F.; Humanes, M.; Leppin, J.; Heinze, K.; Wever, R.; Schröder, H.C.; Müller, W.E.G.; Tremel, W.

    2011-01-01

    V2O5 nanowires exhibit an intrinsic catalytic activity towards classical peroxidase substrates such as 2,2-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS) and 3,3,5,5,-tetramethylbenzdine (TMB) in the presence of H2O2. These V2O5 nanowires show an optimum reactivity at a pH of 4.0 and the

  9. Thermal expansion coefficients of obliquely deposited MgF2 thin films and their intrinsic stress.

    Science.gov (United States)

    Jaing, Cheng-Chung

    2011-03-20

    This study elucidates the effects of columnar angles and deposition angles on the thermal expansion coefficients and intrinsic stress behaviors of MgF2 films with columnar microstructures. The behaviors associated with temperature-dependent stresses in the MgF2 films are measured using a phase-shifting Twyman-Green interferometer with a heating stage and the application of a phase reduction algorithm. The thermal expansion coefficients of MgF2 films at various columnar angles were larger than those of glass substrates. The intrinsic stress in the MgF2 films with columnar microstructures was compressive, while the thermal stress was tensile. The thermal expansion coefficients of MgF2 films with columnar microstructures and their intrinsic stress evidently depended on the deposition angle and the columnar angle.

  10. Simbol-X: a formation flight mission with an unprecedented imaging capability in the 0.5-80 keV energy band

    Science.gov (United States)

    Tagliaferri, Gianpiero; Ferrando, Philippe; Le Duigou, Jean-Michel; Pareschi, Giovanni; Laurent, Philippe; Malaguti, Giuseppe; Clédassou, Rodolphe; Piermaria, Mauro; La Marle, Olivier; Fiore, Fabrizio; Giommi, Paolo

    2017-11-01

    The discovery of X-ray emission from cosmic sources in the 1960s has opened a new powerful observing window on the Universe. In fact, the exploration of the X-ray sky during the 70s-90s has established X-ray astronomy as a fundamental field of astrophysics. Today, the emission from astrophysical sources is by large best known at energies below 10 keV. The main reason for this situation is purely technical since grazing incidence reflection has so far been limited to the soft X-ray band. Above 10 keV all the observations have been obtained with collimated detectors or coded mask instruments. To make a leap step forward in Xray astronomy above 10 keV it is necessary to extend the principle of focusing X ray optics to higher energies, up to 80 keV and beyond. To this end, ASI and CNES are presently studying the implementation of a X-ray mission called Simbol-X. Taking advantage of emerging technology in mirror manufacturing and spacecraft formation flying, Simbol-X will push grazing incidence imaging up to 80 keV and beyond, providing a strong improvement both in sensitivity and angular resolution compared to all instruments that have operated so far above 10 keV. This technological breakthrough will open a new highenergy window in astrophysics and cosmology. Here we will address the problematic of the development for such a distributed and deformable instrument. We will focus on the main performances of the telescope, like angular resolution, sensitivity and source localization. We will also describe the specificity of the calibration aspects of the payload distributed over two satellites and therefore in a not "frozen" configuration.

  11. Characterisation of a monolithic active pixel sensor for electron detection in the energy range 10-20 keV

    International Nuclear Information System (INIS)

    Matheson, J.; Moldovan, G.; Clark, A.; Prydderch, M.; Turchetta, R.; Derbyshire, G.; Kirkland, A.; Allinson, N.

    2009-01-01

    As part of a feasibility study into the use of novel electron detectors for X-ray photoelectron emission microscopes (XPEEM), we have characterised the imaging performance of a back-illuminated monolithic active pixel sensor (MAPS) operating under both integrating and counting modes for electrons in the energy range 10-20 keV. For integrating mode, we present the detective quantum efficiency (DQE), which shows marked improvements over conventional indirect detectors based on microchannel plates. We also present the modulation transfer function (MTF) and noise power spectrum (NPS), again demonstrating significantly improved performance. For counting mode, we present the quantum efficiency (QE) as a function of incident electron energy. We have evaluated the charge collection efficiency (CCE) and we thereby demonstrate the presence of a ∼200 nm thick dead layer that is linked with reduced CCE at low electron energies. Based on our findings, we believe that the MAPS technology is well matched to future XPEEM instruments using aberration correction.

  12. Producción de acido láctico por Lactobacillus plantarum L10 en cultivos batch y continuo

    Directory of Open Access Journals (Sweden)

    Waldir Estela

    2013-04-01

    Full Text Available Se ha ensayado a escala de laboratorio la cepa Lactobacillus plantarum L10, para la producción de ácido láctico en cultivos batch y continuo; además se ha optimizado la composición del medio y las condiciones de cultivo para este propósito. Los mejores parámetros de producción de ácido láctico encontrados en cultivo batch fueron los siguientes: YP/S 86,1%; PP 5,4 g/L/h; unido a YX/S 13,2%; PX 1,2 g/L/h y μ = 0,2 h-1, el cultivo se ha llevado a cabo en un medio conteniendo glucosa 70 g/L; extracto de levadura 12,1 g/L; KH2PO4 1,2 g/L; (NH42HPO4 1,2 g/L; citrato de amonio 3,0 g/L; MgSO4. 7H2O 0,3 g/L y MnSO4. 4H2O 0,03 g/L. Así mismo los mejores parámetros de producción de ácido láctico encontrados en cultivo continuo fueron los siguientes: YP/S 96%; P´P 6,0 g/L/h; unido a YX/S 19 %; P´X 1,2 g/L/h; y tasa de dilución (D 0,46 h-1.

  13. Comparative genomics and transcriptome analysis of Lactobacillus rhamnosus ATCC 11443 and the mutant strain SCT-10-10-60 with enhanced L-lactic acid production capacity.

    Science.gov (United States)

    Sun, Liang; Lu, Zhilong; Li, Jianxiu; Sun, Feifei; Huang, Ribo

    2018-02-01

    Mechanisms for high L-lactic acid production remain unclear in many bacteria. Lactobacillus rhamnosus SCT-10-10-60 was previously obtained from L. rhamnosus ATCC 11443 via mutagenesis and showed improved L-lactic acid production. In this study, the genomes of strains SCT-10-10-60 and ATCC 11443 were sequenced. Both genomes are a circular chromosome, 2.99 Mb in length with a GC content of approximately 46.8%. Eight split genes were identified in strain SCT-10-10-60, including two LytR family transcriptional regulators, two Rex redox-sensing transcriptional repressors, and four ABC transporters. In total, 60 significantly up-regulated genes (log 2 fold-change ≥ 2) and 39 significantly down-regulated genes (log 2 fold-change ≤ - 2) were identified by a transcriptome comparison between strains SCT-10-10-60 and ATCC 11443. KEGG pathway enrichment analysis revealed that "pyruvate metabolism" was significantly different (P < 0.05) between the two strains. The split genes and the differentially expressed genes involved in the "pyruvate metabolism" pathway are probably responsible for the increased L-lactic acid production by SCT-10-10-60. The genome and transcriptome sequencing information and comparison of SCT-10-10-60 with ATCC 11443 provide insights into the anabolism of L-lactic acid and a reference for improving L-lactic acid production using genetic engineering.

  14. Experimental cross sections for two-electron capture into nitrogen autoionising states in Nsup(q+) (q=6,7) on He and H2 collisions at 10.5q keV

    International Nuclear Information System (INIS)

    Bordenave-Montesquieu, A.; Benoit-Cattin, P.; Gleizes, A.; Marrakchi, A.I.

    1985-01-01

    Singly differential cross sections for two-electron capture into autoionising states (nl,n'l') with n=2,3,4 and n'>=n in Nsup(q+) (q=6,7) on He and H 2 collisions have been measured at 10,5q ke V collision energy and an observation angle thetasub(lab)=11.6 0 . Total cross sections are estimated assuming isotropic angular distributions. (orig.)

  15. Evolution of nanodot morphology on polycarbonate (PC) surfaces by 40 keV Ar"+

    International Nuclear Information System (INIS)

    Goyal, Meetika; Chawla, Mahak; Gupta, Divya; Shekhawat, Nidhi; Sharma, Annu; Aggarwal, Sanjeev

    2016-01-01

    In the present paper we have discussed the effect of 40 keV Ar"+ ions irradiation on nanoscale surface morphology of Polycarbonate (PC) substrate. Specimens were sputtered at off normal incidences of 30°, 40° and 50° with the fluence of 1 × 10"1"6 Ar"+cm"−"2. The topographical behaviour of specimens was studied by using Atomic Force Microscopy (AFM) technique. AFM study demonstrates the evolution of nano dot morphology on PC specimens on irradiating with 1 × 10"1"6 Ar"+cm"−"2. Average size of dots varied from 37-95 nm in this specified range of incidence while density of dots varied from 0.17-3.0 × 107 dotscm"−"2. Such variations in morphological features have been supported by estimation of ion range and sputtering yield through SRIM simulations.

  16. Validation of the intrinsic spatial efficiency method for non cylindrical homogeneous sources using MC simulation

    Energy Technology Data Exchange (ETDEWEB)

    Ortiz-Ramírez, Pablo, E-mail: rapeitor@ug.uchile.cl; Ruiz, Andrés [Departamento de Física, Facultad de Ciencias, Universidad de Chile (Chile)

    2016-07-07

    The Monte Carlo simulation of the gamma spectroscopy systems is a common practice in these days. The most popular softwares to do this are MCNP and Geant4 codes. The intrinsic spatial efficiency method is a general and absolute method to determine the absolute efficiency of a spectroscopy system for any extended sources, but this was only demonstrated experimentally for cylindrical sources. Due to the difficulty that the preparation of sources with any shape represents, the simplest way to do this is by the simulation of the spectroscopy system and the source. In this work we present the validation of the intrinsic spatial efficiency method for sources with different geometries and for photons with an energy of 661.65 keV. In the simulation the matrix effects (the auto-attenuation effect) are not considered, therefore these results are only preliminaries. The MC simulation is carried out using the FLUKA code and the absolute efficiency of the detector is determined using two methods: the statistical count of Full Energy Peak (FEP) area (traditional method) and the intrinsic spatial efficiency method. The obtained results show total agreement between the absolute efficiencies determined by the traditional method and the intrinsic spatial efficiency method. The relative bias is lesser than 1% in all cases.

  17. Predictive value of [-2]propsa (p2psa and its derivatives for the prostate cancer detection in the 2.0 to 10.0ng/mL PSA range

    Directory of Open Access Journals (Sweden)

    I. Vukovic

    Full Text Available ABSTRACT Introduction To assess predictive value of new tumor markers, precursor of prostate specific antigen (p2PSA and its derivates-%p2PSA and prostate health index (PHI in detection of patients with indolent and aggressive prostate cancer (PC in a subcohort of man whose total PSA ranged from 2 to 10ng/mL. Materials and Methods This cross-sectional study included 129 consecutive male patients aged over 50 years, with no previous history of PC and with normal digital rectal examination findings, but with serum PSA in interval between 2 and 10ng/mL. All patients underwent standard transrectal ultrasonography guided prostate biopsy for the first time. For all patients, serum PSA, free PSA (fPSA and p2PSA were measured and PHI and %p2PSA were calculated. Results PHI and %p2PSA levels were significanlty higher in patients with PC compared to those without this malignancy. The same findings have been observed in group of patients with Gleason score ≥7 compared to those with Gleason score <7. ROC analysis reveled the highest area under the curve with these two markers. Multivariate logistic regression showed significant improvement in PC detection and its agressive form (assumed as Gleason score ≥7. Conclusions New markers, derivates of p2PSA (especially %p2PSA and PHI, represente potentially very important clinical tool for predicting presence of PC, and even more important, to discriminate patients with Gleason score <7 from those with Gleason score ≥7 with total PSA in range from 2 to 10ng/mL.

  18. Predictive value of [-2]propsa (p2psa) and its derivatives for the prostate cancer detection in the 2.0 to 10.0ng/mL PSA range.

    Science.gov (United States)

    Vukovic, I; Djordjevic, D; Bojanic, N; Babic, U; Soldatovic, I

    2017-01-01

    To assess predictive value of new tumor markers, precursor of prostate specific antigen (p2PSA) and its derivates-%p2PSA and prostate health index (PHI) in detection of patients with indolent and aggressive prostate cancer (PC) in a subcohort of man whose total PSA ranged from 2 to 10ng/mL. This cross-sectional study included 129 consecutive male patients aged over 50 years, with no previous history of PC and with normal digital rectal examination findings, but with serum PSA in interval between 2 and 10ng/mL. All patients underwent standard transrectal ultrasonography guided prostate biopsy for the first time. For all patients, serum PSA, free PSA (fPSA) and p2PSA were measured and PHI and %p2PSA were calculated. PHI and %p2PSA levels were significanlty higher in patients with PC compared to those without this malignancy. The same findings have been observed in group of patients with Gleason score ≥7 compared to those with Gleason score <7. ROC analysis reveled the highest area under the curve with these two markers. Multivariate logistic regression showed significant improvement in PC detection and its agressive form (assumed as Gleason score ≥7). New markers, derivates of p2PSA (especially %p2PSA and PHI), represente potentially very important clinical tool for predicting presence of PC, and even more important, to discriminate patients with Gleason score <7 from those with Gleason score ≥7 with total PSA in range from 2 to 10ng/mL. Copyright® by the International Brazilian Journal of Urology.

  19. A Combined Model of Charging of the Surface and Bulk of a Dielectric Target by Electrons with the Energies 10-30 keV

    Science.gov (United States)

    Zykov, V. M.; Neiman, D. A.

    2018-04-01

    A physico-mathematical model of the processes of radiation-induced charging of dielectric materials with open surfaces, irradiated with monoenergetic electrons in the energy range 10-30 keV, is described. The model takes into account the relationship between the processes of surface and bulk charging for the given conditions of the experimental design, which accounts for the effect of anomalously long charging of dielectrics after the incident energy of primary electrons during charging is reduced to below the second critical energy for the secondary electronic emission coefficient. The initial fast phase of charging a high-resistivity dielectric material (Al2O3) is investigated. It is shown that as the incident electron energy is approaching the second critical energy during charging, the secondary electronic emission is partially suppressed due to negative charging of the open surface of the dielectric and formation of a near-surface inversion electrical field retarding the electronic emission yield.

  20. Separating intrinsic alignment and galaxy-galaxy lensing

    International Nuclear Information System (INIS)

    Blazek, Jonathan; Seljak, Uroš; Mandelbaum, Rachel; Nakajima, Reiko

    2012-01-01

    The coherent physical alignment of galaxies is an important systematic for gravitational lensing studies as well as a probe of the physical mechanisms involved in galaxy formation and evolution. We develop a formalism for treating this intrinsic alignment (IA) in the context of galaxy-galaxy lensing and present an improved method for measuring IA contamination, which can arise when sources physically associated with the lens are placed behind the lens due to photometric redshift scatter. We apply the technique to recent Sloan Digital Sky Survey (SDSS) measurements of Luminous Red Galaxy lenses and typical ( ∼ L * ) source galaxies with photometric redshifts selected from the SDSS imaging data. Compared to previous measurements, this method has the advantage of being fully self-consistent in its treatment of the IA and lensing signals, solving for the two simultaneously. We find an IA signal consistent with zero, placing tight constraints on both the magnitude of the IA effect and its potential contamination to the lensing signal. While these constraints depend on source selection and redshift quality, the method can be applied to any measurement that uses photometric redshifts. We obtain a model-independent upper-limit of roughly 10% IA contamination for projected separations of r p ≈ 0.1–10 h −1 Mpc. With more stringent photo-z cuts and reasonable assumptions about the physics of intrinsic alignments, this upper limit is reduced to 1–2%. These limits are well below the statistical error of the current lensing measurements. Our results suggest that IA will not present intractable challenges to the next generation of galaxy-galaxy lensing experiments, and the methods presented here should continue to aid in our understanding of alignment processes and in the removal of IA from the lensing signal

  1. Spectroscopic analysis of visible and near UV light emitted by Ar7+ and Ar6+ ions produced in Ar8+-He and Ar8+-H2 collisions at 120 keV

    International Nuclear Information System (INIS)

    Boduch, P.; Chantepie, M.; Hennecart, D.; Husson, X.; Kucal, H.; Lecler, D.; Stolterfoht, N.; Druetta, M.; Fawcett, B.; Wilson, M.

    1992-01-01

    A spectroscopic analysis of light emitted in the 2000-6000A wavelength range by Ar 7+ and Ar 6+ ions produced in Ar 8+ -He and Ar 8+ -H 2 collisions at 120 keV is performed. Well resolved fine structure components of 5s-5p and 5p-5d transitions in Ar VIII following single electron capture are precisely measured. Predominant lines due to double electron capture are observed. In particular, strong lines observed both in Ar 8+ -He and Ar 8+ -H 2 collisions are attributed to Ryberg transitions 3snl-3sn'l' in Ar VII. Attempts at identifications are made for the transition 3dnl-3dn'l' (n=4, 5) with the help of ab initio calculations. Photon emission cross sections for individual lines are determined from the measured data. (orig.)

  2. Breeding L(+)-lactic acid high productive mutant from xylose by nitrogen ions

    International Nuclear Information System (INIS)

    Yang Yingge; Li Wen; Liu Dan; Fan Yonghong; Wang Dongmei; Zheng Zhiming; Yu Zengliang

    2007-01-01

    In order to obtain higher L(+)-lactic acid yield strain fermentating from xylose, the original strain Rhizopus oryzae RLC41-6 was mutated by 10keV N + ion implantation. A mutant strain RQ4012 was obtained. After 72h shake-flask cultivation, the concentration of L(+)-lactic acid reached 74.37g/L, and the productivity was 1.03g/(L.h). Its lactic acid yield was 160% higher than that of the original one, and the mutant strain has high genetic stability. (authors)

  3. Development of 350 keV electron accelerator

    International Nuclear Information System (INIS)

    Qin Jiuchang; Cui Shan; Zhou Wenzhen; Cui Zhipeng; Shi Zhenghu; Lu Zhongcheng; Chen Shangwen; Zhang Lifeng; Cui Zongwei; Huang Jun; Yin Meng

    2007-01-01

    The 350 keV electron accelerator is used for irradiation and production of plas- tic film of the medical infusion bags. The body structure of Van de Graft accelerator and the high voltage power supply of Cockcrof-Walton accelerator are adopted in the electron accelerator. The 350 keV DC power supply is supplied by the high frequency power supply with 14 kHz and 35 kW. The body and DC power supply of the electron accelerator are installed in the tank filled with 0.3 MPa SF 6 . The electron accelerator is compact, self-shielding and suitable for on-line electron beam processing. The main characteristics of the facility are terminal voltage 370 kV, electron beam power 7 kW (350 keV/20 mA), scaning width 70 cm, irradiation dose inuniformity ≤7%. (authors)

  4. EMSH program for calculating electron and photon transport through a matter at energies of 10 keV-1TeV

    International Nuclear Information System (INIS)

    Tayurskij, V.A.

    1989-01-01

    The EMSH program (Electro-Magnetic Shower) for the calculation of 1 keV-1 TeV electron and photon transport through a substance is described. The program is written in FORTRAN for the ES computers. Electron and positron bremsstrahlung, e - e - - and e + e - scattering, positron annihilation, production of e + e - -pairs by photons, photon. Compton scattering, photoelectric effect, photon Rayleigh scattering are taken into account during calculations. The cross sections of these processes are assigned with the 3-10% accuracy. Energy losses for atom ionization and excitation and bremsstrahlung, as well as multiple scattering are taken into account for charged particles. The program is used to calculate electron conversion into positrons, to estimate accelerator radiation background, to simulate electromagnetic showers in electromagntic calorimeters. 37 refs.; 15 figs

  5. 40 keV atomic resolution TEM

    International Nuclear Information System (INIS)

    Bell, David C.; Russo, Christopher J.; Kolmykov, Dmitry V.

    2012-01-01

    Here we present the first atomic resolution TEM imaging at 40 keV using an aberration-corrected, monochromated source TEM. Low-voltage High-Resolution Electron Microscopy (LVHREM) has several advantages, including increased cross-sections for inelastic and elastic scattering, increased contrast per electron and improved spectroscopy efficiency, decreased delocalization effects and reduced knock-on damage. Together, these often improve the contrast to damage ratio obtained on a large class of samples. Third-order aberration correction now allows us to operate the TEM at low energies while retaining atomic resolution, which was previously impossible. At low voltage the major limitation to resolution becomes the chromatic aberration limit. We show that using a source monochromator we are able to reduce the effect of chromatic aberration and achieve a usable high-resolution limit at 40 keV to less than 1 Å. We show various materials' examples of the application of the technique to image graphene and silicon, and compare atomic resolution images with electron multislice simulations. -- Highlights: ► We present the first atomic resolution images recorded at 40 keV using an aberration-corrected, monochromated TEM. ► We show information transfer measured to better than 1 Å. ► At 40 keV an aberration-corrected monochromated TEM is limited by fifth-order spherical aberration. ► We show that using a monochromator the effect of chromatic aberration is reduced to enable high resolution imaging. ► Low voltage high resolution electron microscopy will be beneficial for imaging the organic/inorganic materials interface.

  6. Radiation blistering in Inconel-625 due to 100 KeV helium ion irradiation

    International Nuclear Information System (INIS)

    Whitton, J.L.; Rao, A.S.; Kaminsky, M.

    1988-01-01

    The objective of this study was to determine whether the change of angle of incidence of an ion beam impinging on surface blisters during their growth phase (before exfoliation) could influence the blister skin thickness and the blister crater depth. Polished, polycrystalline Inconel-625 samples were irradiated at room temperature and at normal incidence to the major sample surface with 100 keV helium ions to a total dose of 6.24x10 18 ions/cm 2 . The results revealed that many exfoliated blisters leave craters which have two or three concentric pits. The blister skin thickness near the center of the blister was found to agree well with the calculated projected range of 100 keV He ions in nickel. However, the blister skin thickness of some exfoliated blisters along the edge of the fracture surface showed different thicknesses. A model is proposed to explain the observed blister crater/blister fracture features in terms of a change of angle of incidence of the incident ions to the surface during the growth phase of surface blisters. (orig.)

  7. Beta decay anomalies and the 17-keV conundrum

    International Nuclear Information System (INIS)

    Hime, A.

    1993-01-01

    Recent developments in pursuance of the 17-keV neutrino are reviewed. Several different experiments found anomalies in β decay spectra which were consistently interpreted as evidence for a heavy neutrino. On the other hand, recent null results definitively rule out the existence of a 17-keV neutrino, as well as escaping criticisms applicable to earlier experiments. While missing links remain, it seems that any strong evidence for a 17-keV neutrino has vanished. Specifically, the anomalies observed in 35 S and 63 Ni spectra at Oxford can be reinterpreted in terms of electron scattering effects. In addition, the discrepancy amongst internal bremsstrahlung measurements has an instrumental origin, and recent results disfavour a 17-keV neutrino. Anomalies persist in the low energy region of the tritium spectrum which deserve further investigation

  8. Experiences matter: Positive emotions facilitate intrinsic motivation

    OpenAIRE

    Løvoll, Helga Synnevåg; Røysamb, Espen; Vittersø, Joar

    2017-01-01

    https://doi.org/10.1080/23311908.2017.1340083 This paper has two major aims. First, to investigate how positive emotions and intrinsic motivation affect each other over time. Second, to test the effect of positive emotions and intrinsic motivation on subsequent educational choices. Through two ordinary study semesters, 64 sport students in Norway reported on their intrinsic motivation for outdoor activities (twice) as well as positive emotions after two three-day outdoor e...

  9. The effect of homework choices on achievement and intrinsic motivation

    Science.gov (United States)

    Christensen, Emily Fast

    The purpose of this research was to test an intervention of choices in homework on the achievement and intrinsic motivation of seventh-grade science students at a middle school. The intervention was based on concepts from the cognitive evaluation theory of Edward L. Deci and Richard M. Ryan (1985). The subjects were sixteen heterogeneous classes of seventh-grade students, who were divided among four teachers. Two randomly chosen classes from each teacher received choices in their homework and the remaining two classes of each teacher received similar homework assignments without choices. Two hypotheses were developed for this study: (1) Seventh-grade science students given choices in their homework would show an increase in intrinsic motivation as measured on a motivation orientation measure, compared to students not given choices in their homework, and (2) Seventh-grade science students given choices in their homework would show an increase in achievement on an achievement measure, compared to students not given choices in their homework. Having choices in homework did not increase intrinsic motivation or achievement. However, students who did their homework did significantly better on the posttest, and students who were more intrinsically motivated did significantly better on the posttest. Just doing the homework was important for achievement, and intrinsic motivation was linked to achievement.

  10. Carotid dual-energy CT angiography: Evaluation of low keV calculated monoenergetic datasets by means of a frequency-split approach for noise reduction at low keV levels.

    Science.gov (United States)

    Riffel, Philipp; Haubenreisser, Holger; Meyer, Mathias; Sudarski, Sonja; Morelli, John N; Schmidt, Bernhard; Schoenberg, Stefan O; Henzler, Thomas

    2016-04-01

    Calculated monoenergetic ultra-low keV datasets did not lead to improved contrast-to-noise ratio (CNR) due to the dramatic increase in image noise. The aim of the present study was to evaluate the objective image quality of ultra-low keV monoenergetic images (MEIs) calculated from carotid DECT angiography data with a new monoenergetic imaging algorithm using a frequency-split technique. 20 patients (12 male; mean age 53±17 years) were retrospectively analyzed. MEIs from 40 to 120 keV were reconstructed using the monoenergetic split frequency approach (MFSA). Additionally MEIs were reconstructed for 40 and 50 keV using a conventional monoenergetic (CM) software application. Signal intensity, noise, signal-to-noise ratio (SNR) and CNR were assessed in the basilar, common, internal carotid arteries. Ultra-low keV MEIs at 40 keV and 50 keV demonstrated highest vessel attenuation, significantly greater than those of the polyenergetic images (PEI) (all p-values 0.05). Thus MEIs with MFSA showed significantly higher SNR and CNR compared to MEIs with CM. Combining the lower spatial frequency stack for contrast at low keV levels with the high spatial frequency stack for noise at high keV levels (frequency-split technique) leads to improved image quality of ultra-low keV monoenergetic DECT datasets when compared to previous monoenergetic reconstruction techniques without the frequency-split technique. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Functional Anthology of Intrinsic Disorder. III. Ligands, Postranslational Modifications and Diseases Associated with Intrinsically Disordered Proteins

    Science.gov (United States)

    Xie, Hongbo; Vucetic, Slobodan; Iakoucheva, Lilia M.; Oldfield, Christopher J.; Dunker, A. Keith; Obradovic, Zoran; Uversky, Vladimir N.

    2008-01-01

    Currently, the understanding of the relationships between function, amino acid sequence and protein structure continues to represent one of the major challenges of the modern protein science. As much as 50% of eukaryotic proteins are likely to contain functionally important long disordered regions. Many proteins are wholly disordered but still possess numerous biologically important functions. However, the number of experimentally confirmed disordered proteins with known biological functions is substantially smaller than their actual number in nature. Therefore, there is a crucial need for novel bioinformatics approaches that allow projection of the current knowledge from a few experimentally verified examples to much larger groups of known and potential proteins. The elaboration of a bioinformatics tool for the analysis of functional diversity of intrinsically disordered proteins and application of this data mining tool to >200,000 proteins from Swiss-Prot database, each annotated with at least one of the 875 functional keywords was described in the first paper of this series (Xie H., Vucetic S., Iakoucheva L.M., Oldfield C.J., Dunker A.K., Obradovic Z., Uversky V.N. (2006) Functional anthology of intrinsic disorder. I. Biological processes and functions of proteins with long disordered regions. J. Proteome Res.). Using this tool, we have found that out of the 711 Swiss-Prot functional keywords associated with at least 20 proteins, 262 were strongly positively correlated with long intrinsically disordered regions, and 302 were strongly negatively correlated. Illustrative examples of functional disorder or order were found for the vast majority of keywords showing strongest positive or negative correlation with intrinsic disorder, respectively. Some 80 Swiss-Prot keywords associated with disorder- and order-driven biological processes and protein functions were described in the first paper (Xie H., Vucetic S., Iakoucheva L.M., Oldfield C.J., Dunker A.K., Obradovic

  12. Measurement of multilayer reflectivities from 8 keV to 130 keV

    DEFF Research Database (Denmark)

    Hoeghoej, P.; Joensen, K. D.; Christensen, Finn Erland

    1993-01-01

    This paper presents measurements of specular and non-specular reflectivities of a W/Si multilayer with period d=135.1 A. Angular dispersive measurements were performed at 8.05 keY and 59.3 keY, while energy dispersive measurements were made in the range of 17 keV to 130 keY. At an incidence angle...

  13. Analysis list: Ash2l [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Ash2l Blood + mm9 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/target/Ash2l.1.tsv... http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/target/Ash2l.5.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/target/Ash2...l.10.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/colo/Ash2l.Blood.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/colo/Blood.gml ...

  14. Neoclassical Diffusion of Radiation-Belt Electrons Across Very Low L-Shells

    Science.gov (United States)

    Cunningham, Gregory S.; Loridan, Vivien; Ripoll, Jean-François; Schulz, Michael

    2018-04-01

    In the presence of drift-shell splitting intrinsic to the International Geomagnetic Reference Field magnetic field model, pitch angle scattering from Coulomb collisions experienced by radiation-belt electrons in the upper atmosphere and ionosphere produces extra radial diffusion, a form of neoclassical diffusion. The strength of the neoclassical radial diffusion at L nuclear detonation. The data show apparent lifetimes 10-100 times as long as would have been expected from collisional pitch angle diffusion and Coulomb drag alone. Our model reproduces apparent lifetimes for >0.5-MeV electrons in the region 1.14 < L < 1.26 to within a factor of 2 (comparable to the uncertainty quoted for the observations). We conclude that neoclassical radial diffusion (resulting from drift-shell splitting intrinsic to International Geomagnetic Reference Field's azimuthal asymmetries) mitigates the decay expected from collisional pitch angle diffusion and inelastic energy loss alone and thus contributes importantly to the long apparent lifetimes observed at these low L-shells.

  15. Absolute calibration of the Agfa Structurix series films at energies between 2.7 and 6.2 keV.

    Science.gov (United States)

    Lanier, N E; Cowan, J S

    2014-11-01

    Although photo-emulsion technology is many decades old, x-ray film still remains a key asset for diagnosing hydrodynamic features in High-Energy Density (HED) experiments. For decades, the preferred option had been Kodak's direct exposure film. After its discontinuance in 2004, the push to find alternatives began. In many situations, the Agfa Structurix series offers the most favorable substitute, but being new to the HED community, its characterization was lacking. To remedy this, recent experiments, conducted at Brookhaven's National Synchrotron Light Source, provide absolute, monochromatic calibration data for the Agfa Structurix series films at K-shell backlighter energies between 2.7 and 6.2 keV. Absolute response curves are presented for Agfa D8, D7, D4, D4sc, D3, and D2. Moreover, the transmission of each film type is also measured.

  16. A balloon-borne solid state cosmic X-ray detector

    International Nuclear Information System (INIS)

    Proctor, R.; Pietsch, W.; Reppin, C.

    1982-01-01

    On 9th May 1980 a MPI/AIT hard X-ray balloon payload successfully observed numerous cosmic X-ray sources. The payload consisted of a 2400 cm 2 Phoswich detector and a 114 cm 2 solid state detector. The solid state detector is described in this report. It consists of six intrinsic germanium planar crystals in a vacuum cryostat cooled by liquid nitrogen. The detector operates in the hard X-ray energy range of 20-150 keV and had in-flight a mean energy resolution of 2.75 keV at 60 keV. A hexagonal molybdenum collimator defined the field of view as approximately 4 0 fwhm. A CsI(Na) and plastic active shield and passive shielding provided background rejection. Mean background values of 1.3 X 10 -3 counts/(sec x cm 2 x keV) at 60 keV were obtained. (orig.)

  17. Determining the Covering Factor of Compton-Thick Active Galactic Nuclei with NuSTAR

    Science.gov (United States)

    Brightman, M.; Balokovic, M.; Stern, D.; Arevalo, P.; Ballantyne, D. R.; Bauer, F. E.; Boggs, S. E.; Craig, W. W.; Christensen, F. E.; Zhang, W. W.

    2015-01-01

    The covering factor of Compton-thick (CT) obscuring material associated with the torus in active galactic nuclei (AGNs) is at present best understood through the fraction of sources exhibiting CT absorption along the line of sight (N(sub H) greater than 1.5 x 10(exp 24) cm(exp -2)) in the X-ray band, which reveals the average covering factor. Determining this CT fraction is difficult, however, due to the extreme obscuration. With its spectral coverage at hard X-rays (greater than 10 keV), Nuclear Spectroscopic Telescope Array (NuSTAR) is sensitive to the AGNs covering factor since Compton scattering of X-rays off optically thick material dominates at these energies. We present a spectral analysis of 10 AGNs observed with NuSTAR where the obscuring medium is optically thick to Compton scattering, so-called CT AGNs. We use the torus models of Brightman and Nandra that predict the X-ray spectrum from reprocessing in a torus and include the torus opening angle as a free parameter and aim to determine the covering factor of the CT gas in these sources individually. Across the sample we find mild to heavy CT columns, with N(sub H) measured from 10(exp 24) to 10(exp 26) cm(exp -2), and a wide range of covering factors, where individual measurements range from 0.2 to 0.9. We find that the covering factor, f(sub c), is a strongly decreasing function of the intrinsic 2-10 keV luminosity, L(sub X), where f(sub c) = (-0.41 +/- 0.13)log(sub 10)(L(sub X)/erg s(exp -1))+18.31 +/- 5.33, across more than two orders of magnitude in L(sub X) (10(exp 41.5) - 10(exp 44) erg s(exp -1)). The covering factors measured here agree well with the obscured fraction as a function of LX as determined by studies of local AGNs with L(sub X) greater than 10(exp 42.5) erg s(exp -1).

  18. A New Compton-Thick AGN in Our Cosmic Backyard: Unveiling the Buried Nucleus in NGC 1448 with NuSTAR

    Science.gov (United States)

    Annuar, A.; Alexander, D. M.; Ghandi, P.; Lansbury, G. B.; Asmus, D.; Ballantyne, D. R.; Bauer, F. E.; Boggs, S. E.; Boorman, P. G.; Brandt, W. N.; hide

    2017-01-01

    NGC 1448 is one of the nearest luminous galaxies [L(sub 8) - 1000 micrometers is greater than 10(exp. 9) Solar Luminosity] to ours (z = 0.00390), and yet the active galactic nucleus (AGN) it hosts was only recently discovered, in 2009. In this paper, we present an analysis of the nuclear source across three wavebands: mid-infrared (MIR) continuum, optical, and X-rays. We observed the source with the Nuclear Spectroscopic Telescope Array (NuSTAR), and combined these data with archival Chandra data to perform broadband X-ray spectral fitting ( approx. equals 0.5 - 40 keV) of the AGN for the first time. Our X-ray spectral analysis reveals that the AGN is buried under a Compton-thick (CT) column of obscuring gas along our line of sight, with a column density of N(sub H)(los) approx. greater than 2.5 x 10(exp. 24) cm(exp. -2). The best-fitting torus models measured an intrinsic 2-10 keV luminosity of L(sub 2)-10,int = (3.5 - 7.6) x 10(exp. 40) erg s(exp. -1), making NGC 1448 one of the lowest luminosity CTAGNs known. In addition to the NuSTAR observation, we also performed optical spectroscopy for the nucleus in this edge-on galaxy using the European Southern Observatory New Technology Telescope. We reclassify the optical nuclear spectrum as a Seyfert on the basis of the Baldwin- Philips-Terlevich diagnostic diagrams, thus identifying the AGN at optical wavelengths for the first time. We also present high spatial resolution MIR observations of NGC 1448 with Gemini/T-ReCS, in which a compact nucleus is clearly detected. The absorption-corrected 2-10 keV luminosity measured from our X-ray spectral analysis agrees with that predicted from the optical [O III] Lamda 5007 A emission line and the MIR 12 micrometer continuum, further supporting the CT nature ofthe AGN.

  19. Measurement of the mass energy-absorption coefficient of air for x-rays in the range from 3 to 60 keV.

    Science.gov (United States)

    Buhr, H; Büermann, L; Gerlach, M; Krumrey, M; Rabus, H

    2012-12-21

    For the first time the absolute photon mass energy-absorption coefficient of air in the energy range of 10 to 60 keV has been measured with relative standard uncertainties below 1%, considerably smaller than those of up to 2% assumed for calculated data. For monochromatized synchrotron radiation from the electron storage ring BESSY II both the radiant power and the fraction of power deposited in dry air were measured using a cryogenic electrical substitution radiometer and a free air ionization chamber, respectively. The measured absorption coefficients were compared with state-of-the art calculations and showed an average deviation of 2% from calculations by Seltzer. However, they agree within 1% with data calculated earlier by Hubbell. In the course of this work, an improvement of the data analysis of a previous experimental determination of the mass energy-absorption coefficient of air in the range of 3 to 10 keV was found to be possible and corrected values of this preceding study are given.

  20. 150 keV accelerator as pulsed neutron source; Acelerador de 150 keV como fuente de neutrones pulsada

    Energy Technology Data Exchange (ETDEWEB)

    Cordero, F

    1970-07-01

    The project of a 150 keV Cockcroft-Walton accelerator built at J.E.N. is described. Beam currents of more than 10 mA, with a neutron intensity of 10{sup 1}1 n.s{sup 1}, are obtained. Also, we report some research made in connection with that project. The role of the contamination in the vacuum system and the performance of the pumps and gauges pumping deuterium gas are studied. Sinusoidal pulses are employed as an analysis method of the discharge in the ion source and the performance of the extracting-focusing system. The parameters of the beam leaving the ion source have been determined; these are used to calculate the electrostatic lenses with the gaussian optics. Measurements concerning deuterium and tritium targets as neutron sources have been made and the processes affecting their practical service life are analyzed. (Author) 71 refs.

  1. L-R asymmetry in gut's

    International Nuclear Information System (INIS)

    Karadayi, H.R.

    1982-01-01

    An idea of L-R asymmetry is proposed for the grand unification schemes. The idea provides an intrinsic mechanism to obtain standard model charges of fermions in the case of more than one weak gauge boson. It is elaborated within a scheme based on the partial symmetry SU(4)sub(C)xSU(2)sub(L)xSU(2)sub(R) where the coupling constants gsub(L) and gsub(R) corresponding to the chiral SU(2) factors are assumed to be different from each other. Then, the embedding of this structure within the simple symmetry SO(10) is shown. In both cases, a consistent description of vector particle masses is given. These two schemes are considered as primary models to realize the L-R asymmetry idea due to the lack of family unification. However, in a subsequent work, we will show that the SO(14) unification of the three families can be obtained within the framework of L-R asymmetry. All formulations are carried out with the aid of a mathematical method that we recently proposed for the Lie algebra representations of classical groups. (author)

  2. A 20 keV electron gun system for the electron irradiation experiments

    International Nuclear Information System (INIS)

    Mahapatra, S.K.; Dhole, S.D.; Bhoraskar, V.N.

    2005-01-01

    An electron gun consisting of cathode, focusing electrode, control electrode and anode has been designed and fabricated for the electron irradiation experiments. This electron gun can provide electrons of any energy over the range 1-20 keV, with current upto 50 μA. This electron gun and a Faraday cup are mounted in the cylindrical chamber. The samples are fixed on the Faraday cup and irradiated with electrons at a pressure ∼10 -7 mbar. The special features of this electron gun system are that, at any electron energy above 1 keV, the electron beam diameter can be varied from 5 to 120 mm on the Faraday cup mounted at a distance of 200 mm from the anode in the chamber. The variation in the electron current over the beam spot of 120 mm diameter is less than 15% and the beam current stability is better than 5%. This system is being used for studying the irradiation effects of 1-20 keV energy electrons on the space quality materials in which the irradiation time may vary from a few tens of seconds to hours

  3. A 20 keV electron gun system for the electron irradiation experiments

    Energy Technology Data Exchange (ETDEWEB)

    Mahapatra, S.K. [Department of Physics, University of Pune, Pune 411007 (India); Dhole, S.D. [Department of Physics, University of Pune, Pune 411007 (India); Bhoraskar, V.N. [Department of Physics, University of Pune, Pune 411007 (India)]. E-mail: vnb@physics.unipune.ernet.in

    2005-01-01

    An electron gun consisting of cathode, focusing electrode, control electrode and anode has been designed and fabricated for the electron irradiation experiments. This electron gun can provide electrons of any energy over the range 1-20 keV, with current upto 50 {mu}A. This electron gun and a Faraday cup are mounted in the cylindrical chamber. The samples are fixed on the Faraday cup and irradiated with electrons at a pressure {approx}10{sup -7} mbar. The special features of this electron gun system are that, at any electron energy above 1 keV, the electron beam diameter can be varied from 5 to 120 mm on the Faraday cup mounted at a distance of 200 mm from the anode in the chamber. The variation in the electron current over the beam spot of 120 mm diameter is less than 15% and the beam current stability is better than 5%. This system is being used for studying the irradiation effects of 1-20 keV energy electrons on the space quality materials in which the irradiation time may vary from a few tens of seconds to hours.

  4. 46 CFR 30.10-33 - Great Lakes-TB/L.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Great Lakes-TB/L. 30.10-33 Section 30.10-33 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS GENERAL PROVISIONS Definitions § 30.10-33 Great Lakes—TB/L. Under this designation shall be included all tank vessels navigating the Great Lakes. ...

  5. A system to measure isomeric state half-lives in the 10 ns to 10 μs range

    Energy Technology Data Exchange (ETDEWEB)

    Toufen, D. L., E-mail: dennis@if.usp.br [Institute of Physics, University of São Paulo, C.P. 66318, 05315-970 São Paulo, São Paulo (Brazil); Federal Institute of Education, Science and Technology of São Paulo - IFSP, 07115-000 Guarulhos, São Paulo (Brazil); Allegro, P. R. P.; Medina, N. H.; Oliveira, J. R. B.; Cybulska, E. W.; Seale, W. A.; Ribas, R. V. [Institute of Physics, University of São Paulo, C.P. 66318, 05315-970 São Paulo, São Paulo (Brazil); Linares, R. [Fluminense Federal University, 24220-900 Niterói, Rio de Janeiro (Brazil); Silveira, M. A. G. [Universitary Center of FEI, 09850-901 São Bernardo do Campo, São Paulo (Brazil)

    2014-07-15

    The Isomeric State Measurement System (SISMEI) was developed to search for isomeric nuclear states produced by fusion-evaporation reactions. The SISMEI consists of 10 plastic phoswich telescopes, two lead shields, one NaI(Tl) scintillation detector, two Compton suppressed HPGe γ-ray detectors, and a cone with a recoil product catcher. The new system was tested at the 8 UD Pelletron tandem accelerator of the University of São Paulo with the measurement of two known isomeric states: {sup 54}Fe, 10{sup +} state (E = 6527.1 (11) keV, T{sub 1/2} = 364(7) ns) and the 5/2{sup +} state of {sup 19}F (E = 197.143 (4) keV, T{sub 1/2} = 89.3 (10) ns). The results indicate that the system is capable of identifying delayed transitions, of measuring isomeric state lifetimes, and of identifying the feeding transitions of the isomeric state through the delayed γ-γ coincidence method. The measured half-life for the 10{sup +} state was T{sub 1/2} = 365(14) ns and for the 5/2{sup +} state, 100(36) ns.

  6. A system to measure isomeric state half-lives in the 10 ns to 10 μs range

    Science.gov (United States)

    Toufen, D. L.; Allegro, P. R. P.; Medina, N. H.; Oliveira, J. R. B.; Cybulska, E. W.; Seale, W. A.; Linares, R.; Silveira, M. A. G.; Ribas, R. V.

    2014-07-01

    The Isomeric State Measurement System (SISMEI) was developed to search for isomeric nuclear states produced by fusion-evaporation reactions. The SISMEI consists of 10 plastic phoswich telescopes, two lead shields, one NaI(Tl) scintillation detector, two Compton suppressed HPGe γ-ray detectors, and a cone with a recoil product catcher. The new system was tested at the 8 UD Pelletron tandem accelerator of the University of São Paulo with the measurement of two known isomeric states: 54Fe, 10+ state (E = 6527.1 (11) keV, T1/2 = 364(7) ns) and the 5/2+ state of 19F (E = 197.143 (4) keV, T1/2 = 89.3 (10) ns). The results indicate that the system is capable of identifying delayed transitions, of measuring isomeric state lifetimes, and of identifying the feeding transitions of the isomeric state through the delayed γ-γ coincidence method. The measured half-life for the 10+ state was T1/2 = 365(14) ns and for the 5/2+ state, 100(36) ns.

  7. Van Allen Probes Measurements of Energetic Particle Deep Penetration Into the Low L Region (L Storm on 8 April 2016

    Science.gov (United States)

    Zhao, H.; Baker, D. N.; Califf, S.; Li, X.; Jaynes, A. N.; Leonard, T.; Kanekal, S. G.; Blake, J. B.; Fennell, J. F.; Claudepierre, S. G.; Turner, D. L.; Reeves, G. D.; Spence, H. E.

    2017-12-01

    Using measurements from the Van Allen Probes, a penetration event of tens to hundreds of keV electrons and tens of keV protons into the low L shells (L electric field represented by the Volland-Stern model or a uniform dawn-dusk electric field model based on the electric field measurements. It suggests that the underlying physical mechanism responsible for energetic electron deep penetration, which is very important for fully understanding energetic electron dynamics in the low L shells, should be MLT localized.

  8. Functional anthology of intrinsic disorder. 3. Ligands, post-translational modifications, and diseases associated with intrinsically disordered proteins.

    Science.gov (United States)

    Xie, Hongbo; Vucetic, Slobodan; Iakoucheva, Lilia M; Oldfield, Christopher J; Dunker, A Keith; Obradovic, Zoran; Uversky, Vladimir N

    2007-05-01

    devoted to the presentation of 87 Swiss-Prot keywords attributed to the cellular components, domains, technical terms, developmental processes, and coding sequence diversities possessing strong positive and negative correlation with long disordered regions (Vucetic, S.; Xie, H.; Iakoucheva, L. M.; Oldfield, C. J.; Dunker, A. K.; Obradovic, Z.; Uversky, V. N. Functional anthology of intrinsic disorder. 2. Cellular components, domains, technical terms, developmental processes, and coding sequence diversities correlated with long disordered regions. J. Proteome Res. 2007, 5, 1899-1916). Protein structure and functionality can be modulated by various post-translational modifications or/and as a result of binding of specific ligands. Numerous human diseases are associated with protein misfolding/misassembly/misfunctioning. This work concludes the series of papers dedicated to the functional anthology of intrinsic disorder and describes approximately 80 Swiss-Prot functional keywords that are related to ligands, post-translational modifications, and diseases possessing strong positive or negative correlation with the predicted long disordered regions in proteins.

  9. Coherent terahertz emission from Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8} intrinsic Josephson junction stacks

    Energy Technology Data Exchange (ETDEWEB)

    Rudau, Fabian; Gross, Boris; Wieland, Raphael; Judd, Thomas; Koelle, Dieter; Kleiner, Reinhold [Physikalisches Institut and Center for Collective Quantum Phenomena in LISA" +, Universitaet Tuebingen, Tuebingen (Germany); Kinev, Nickolay; Koshelets, Valery [Kotel' nikov Institute of Radio Engineering and Electronics, Moscow (Russian Federation); Tsujimoto, Manabu [Kyoto University, Kyoto (Japan); Ji, Min; Huang, Ya; Zhou, Xianjing; An, Deyue; Wang, Huabing [National Institute for Materials Science, Tsukuba (Japan); Research Institute of Superconductor Electronics, Nanjing University, Nanjing (China); Wu, Peiheng [Research Institute of Superconductor Electronics, Nanjing University, Nanjing (China); Hatano, Takeshi [National Institute for Materials Science, Tsukuba (Japan)

    2015-07-01

    Stacks of intrinsic Josephson junctions, made of the high temperature superconductor Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8}, are promising candidates to be used as generators of electromagnetic waves in the terahertz regime, in principle allowing frequencies up to ∝10 THz. Ranging from 0.4 to 1 THz, coherent emission was detected from large, rectangular stacks, producing several tens of microwatt in power. Despite of several years of research, the mechanism of synchronizing all the junctions in the stack is still not fully understood. We investigated the heat distribution and electromagnetic standing waves in such stacks, as well as the generation of terahertz radiation, using a combination of electric transport measurements, direct radiation detection and low temperature scanning laser microscopy. Recent experimental results from our collaboration will be presented and compared to numerical simulations.

  10. Erosion of volatile elemental condensed gases by keV electron and light-ion bombardment

    International Nuclear Information System (INIS)

    Schou, J.

    1991-11-01

    Erosion of the most volatile elemental gases by keV electron and light-ion bombardment has been studied at the experimental setup at Risoe. The present work includes frozen neon, argon, krypton, nitrogen, oxygen and three hydrogen isotopes, deuterium, hydrogen deuteride and hydrogen. The yield of these condensed gases has been measured as a function of film thickness and primary energy for almost all combinations of primary particles (1-3 keV electrons, 5-10 keV hydrogen- and helium ions) and ices. These and other existing results show that there are substantial common features for the sputtering of frozen elemental gases. Within the two groups, the solid rare gases and the solid molecular gases, the similarity is striking. The hydrogenic solids deviate in some respects from the other elements. The processes that liberate kinetic energy for the particle ejection in sputtering are characteristic of the specific gas. (au) 3 tabs., 12 ills., 159 refs

  11. Gyrofluid Simulations of Intrinsic Rotation Generation in Reversed Shear Plasmas with Internal Transport Barriers

    Science.gov (United States)

    Jhang, Hogun; Kim, S. S.; Kwon, J. M.; Terzolo, L.; Kim, J. Y.; Diamond, P. H.

    2010-11-01

    It is accepted that the intrinsic rotation is generated via the residual stress, which is non-diffusive components of the turbulent Reynolds stress, without external momentum input. The physics leading to the onset of intrinsic rotation in L- and H- mode plasmas have been elucidated elsewhere. However, the physics responsible for the generation and transport of the intrinsic rotation and its relationship to the formation of internal transport barriers (ITBs) in reversed shear (RS) plasmas have not been explored in detail, which is the main subject in the present work. The revised version of the global gyrofluid code TRB is used for this study. It is found that the large intrinsic rotation (˜10-30% of the ion sound speed depending on ITB characteristics) is generated near the ITB region and propagates into the core. The intrinsic rotation increases linearly as the temperature gradient at ITB position increases, albeit not indefinitely. Key parameters related to the symmetry breaking, such as turbulent intensity and its gradient, the flux surface averaged parallel wavenumber are evaluated dynamically during the ITB formation. In particular, the role of reversed shear and the q-profile curvature is presented in relation to the symmetry breaking in RS plasmas.

  12. The Half Life of the 53 keV Level in {sup 197}Pt

    Energy Technology Data Exchange (ETDEWEB)

    Malmskog, S G

    1967-02-15

    The half life of the recently proposed 53 keV level in {sup 197}Pt has been measured to 18.5 {+-} 1.5 nsec using the delayed coincidence technique. This level, which is identified with the f{sub 5/2} single particle state, decays directly to the p{sub 1/2} ground state in {sup 197}Pt. The reduced E2 transition probability for this 53 keV transition has been deduced and compared with the results obtained for the corresponding transitions in other Pt, Hg, and Pb isotopes and with the theoretical predictions by Sorensen and by Wahlborn and Martinson.

  13. β-L-Arabinofuranosylation Conducted by 5-O-(2-pyridinecarbonyl)-L-arabinofuranosyl Trichloroacetimidate.

    Science.gov (United States)

    Li, Hong-Zhan; Ding, Jie; Cheng, Chun-Ru; Chen, Yue; Liang, Xing-Yong

    2018-05-02

    We describe a β-L-arabinofuranosylation method by employing the 5-O-(2-pyridinecarbonyl)-L-arabinofuranosyl trichloroacetimidate 10 as a donor. This approach allows a wide range of acceptor substrates, especially amino acid acceptors, to be used. Stereoselective synthesis of β-(1,4)-L-arabinofuranosyl-(2S, 4R)-4-hydroxy-L-proline (β-L-Araf-L-Hyp 4 ) and its dimer is achieved readily by this method. Both the stereoselectivities and yields of the reactions are excellent. To demonstrate the utility of this methodology, the preparation of a trisaccharide in a one-pot manner was carried out. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. g-factor of the KeV 5/2- state in 197Pt measured by the TDPAC method

    International Nuclear Information System (INIS)

    Saxena, R.N.; Soares, J.C.

    1981-09-01

    The g-factor of the 53 keV state in 197 Pt has been measured using the gamma-gamma time differential perturbed angular correlation (TDPAC) method in an external magnetic field of 25.1 kG. The measurements were performed by utilizing the 346-53 keV gamma cascade in the decay of 95.4 min 197 Pt. The value of the g-factor was obtained to be + 0.335 +- 0.010. This result is compared with the g-factors of similar states in 195 Pt and sup(197,199)Hg. (Author) [pt

  15. Analytical dependence of effective atomic number on the elemental composition of matter and radiation energy in the range 10-1000 keV

    Science.gov (United States)

    Eritenko, A. N.; Tsvetiansky, A. L.; Polev, A. A.

    2018-01-01

    In the present paper, a universal analytical dependence of effective atomic number on the composition of matter and radiation energy is proposed. This enables one to consider the case of a strong difference in the elemental composition with respect to their atomic numbers over a wide energy range. The contribution of photoelectric absorption and incoherent and coherent scattering during the interaction between radiation and matter is considered. For energy values over 40 keV, the contribution of coherent scattering does not exceed approximately 10% that can be neglected at a further consideration. The effective atomic numbers calculated on the basis of the proposed relationships are compared to the results of calculations based on other methods considered by different authors on the basis of experimental and tabulated data on mass and atomic attenuation coefficients. The examination is carried out for both single-element (e.g., 6C, 14Si, 28Cu, 56Ba, and 82Pb) and multi-element materials. Calculations are performed for W1-xCux alloys (x = 0.35; x = 0.4), PbO, ther moluminescent dosimetry compounds (56Ba, 48Cd, 41Sr, 20Ca, 12Mg, and 11Na), and SO4 in a wide energy range. A case with radiation energy between the K- and L1-absorption edges is considered for 82Pb, 74W, 56Ba, 48Cd, and 38Sr. This enables to substantially simplify the calculation of the atomic number and will be useful in technical and scientific fields related to the interaction between X-ray/gamma radiation and matter.

  16. Design of a continuously operated 1-keV deuterium-ion extractor

    International Nuclear Information System (INIS)

    Fink, J.H.

    1978-01-01

    A novel grid structure that is cooled only by radiation and conduction is shown to be capable of continuously extracting 2.5 kA.m -2 of 1-keV positive deuterium ions while dissipating a power loading of 0.4 MW.m -2

  17. Study on the aligned uranium-235 nuclear decay in the neutron energy range of 1.7 eV - 2.15 keV

    International Nuclear Information System (INIS)

    Danelyan, L.S.; Zakharov, Yu.V.; Zykov, V.M.; Mostovoj, V.I.; Stolyarov, V.A.; Biryukov, S.A.; Zysina, N.Yu.; Osochnikov, A.A.; Svettsov, A.V.

    1983-01-01

    Using a time-of-flight neutron spectrometer comparative measurements of intensity of fission reaction on the aligned and non-oriented uranium-235 nuclei have been performed in order to identify the resonances caused by p-neutron capture as well as to determine the p-neutron contribution to the fission cross section in the region of unresolved resonances. In some isolated resonances differences in cross sections on aligned and non-oriented nuclei of about 10% have been observed which can permit to assi.on them to p-resonances. In the region of unresolved resonances in the 0.15-2.15 keV neutron energy range to the accuracy +-1% no changes in the fission cross section during the nuclear alignment have been observ

  18. On the source of the 5-55 keV Heliosphere ENAs measured with Cassini/INCA

    Science.gov (United States)

    Dialynas, Konstantinos; Roelof, Edmond; Mitchell, Donald; Krimigis, Stamatios; Decker, Robert

    2016-07-01

    The Low Energy Charged Particle (LECP) in situ measurements from V1 and V2 have revealed a reservoir of ions and electrons that constitute the heliosheath (HS) after crossing the termination shock (TS) 35deg north and 32deg south of the ecliptic plane at 94 and 84 astronomical units (1 AU= 1.5 x10 ^{8} km), respectively. The outer Heliosphere boundary, the Heliopause (HP), has now been determined in the direction of V1 to be at ˜122 AU. The in situ measurements by each Voyager were placed in a global context by remote sensing images using ENA obtained with the Ion and Neutral Camera (INCA) onboard Cassini orbiting Saturn. The ENA images have revealed a 5.2-55 keV hydrogen (H) ENA region (Belt) that loops through the celestial sphere and contributes to balancing the pressure of the interstellar magnetic field (ISMF). Here we address one of the remaining and most important questions: Where do the 5-55 keV ENAs that INCA measures come from? We analyzed INCA all-sky maps from 2003 to 2015 and compare the solar cycle (SC) variation of the ENAs in both the nose (upstream) and anti-nose (downstream) directions with the intensities of > 30 keV ions (source of ENA through charge exchange-CE with H) measured in-situ by V1 and V2, in overlapping energy bands ˜30-55 keV. ENA intensities decrease during the declining phase of SC23 by ˜x3 from 2003 to 2011 but recover through 2014 (SC24); similarly, V1 and V2 ion intensities also decrease and then recover through 2014. The similarity of time profiles of remotely sensed ENA and locally measured ions are consistent with (a) ENA originating in the HS, and (b) the global HS responding promptly (within ˜1-1.5 years) to outward-propagating solar wind changes throughout the SC. Further, recovery of the Belt during SC24 precedes asymmetrically from south to north in the general direction of the nose. This may be related to the non-symmetric evolution of solar coronal holes during SC recovery.

  19. Molecular treatment of single (dissociative and nondissociative) and double electron capture in He2+ + H2 collisions

    International Nuclear Information System (INIS)

    Errea, L F; Macias, A; Mendez, L; Pons, B; Riera, A

    2003-01-01

    We present close-coupling calculations of total cross sections for single and double electron capture in He 2+ + H 2 collisions in the range 0.5- 25 keV amu -1 , and compare them with experimental data. We confirm the experimental finding that the dominant process for E ∼> 3 keV amu -1 is the nondissociative capture He 2+ + H 2 → He + (2l) + H 2 + (1σ g ), while at lower energies it is dissociative capture leading to He + (1s) + H + + H. Our calculations also show that He(1s2l) is the main output of the two electron capture process. (letter to the editor)

  20. Competitive chiral induction in a 2D molecular assembly: Intrinsic chirality versus coadsorber-induced chirality.

    Science.gov (United States)

    Chen, Ting; Li, Shu-Ying; Wang, Dong; Wan, Li-Jun

    2017-11-01

    Noncovalently introducing stereogenic information is a promising approach to embed chirality in achiral molecular systems. However, the interplay of the noncovalently introduced chirality with the intrinsic chirality of molecules or molecular aggregations has rarely been addressed. We report a competitive chiral expression of the noncovalent interaction-mediated chirality induction and the intrinsic stereogenic center-controlled chirality induction in a two-dimensional (2D) molecular assembly at the liquid/solid interface. Two enantiomorphous honeycomb networks are formed by the coassembly of an achiral 5-(benzyloxy)isophthalic acid (BIC) derivative and 1-octanol at the liquid/solid interface. The preferential formation of the globally homochiral assembly can be achieved either by using the chiral analog of 1-octanol, ( S )-6-methyl-1-octanol, as a chiral coadsorber to induce chirality to the BIC assembly via noncovalent hydrogen bonding or by covalently linking a chiral center in the side chain of BIC. Both the chiral coadsorber and the intrinsically chiral BIC derivative can act as a chiral seeds to induce a preferred handedness in the assembly of the achiral BIC derivatives. Furthermore, the noncovalent interaction-mediated chirality induction can restrain or even overrule the manifestation of the intrinsic chirality of the BIC molecule and dominate the handedness of the 2D molecular coassembly. This study provides insight into the interplay of intrinsically chiral centers and external chiral coadsorbers in the chiral induction, transfer, and amplification processes of 2D molecular assembly.

  1. Extrinsic and intrinsic blood supply to the optic chiasm.

    Science.gov (United States)

    Salaud, Céline; Ploteau, Stéphane; Blery, Pauline; Pilet, Paul; Armstrong, Olivier; Hamel, Antoine

    2018-04-01

    Although there have been many studies of the arterial cerebral blood supply, only seven have described the optic chiasm (OC) blood supply and their results are contradictory. The aim of this study was to analyze the extrinsic and intrinsic OC blood supply on cadaveric specimens using dissections and microcomputer tomography (Micro-CT). Thirteen human specimens were dissected and the internal or common carotid arteries were injected with red latex, China Ink with gelatin or barium sulfate. Three Micro-CTs were obtained to reveal the intrinsic blood supply to the OC. The superior hypophyseal arteries (SupHypA) (13/13) and posterior communicating artery (PCoA) (12/13) supplied the pial network on the inferior side of the OC. The first segment of the anterior cerebral artery (ACA) (10/10), SupHypA (7/10), the anterior communicating artery (ACoA) (9/10), and PComA (1/10) supplied the pial network of its superior side. The intrinsic OC blood supply was divided into three networks (two lateral and one central). Capillaries entering the OC originated principally from the inferior pial network. The lateral network capillaries had the same orientation as the visual lateral pathways, but the central network was not correlated with the nasal fibers crossing into the OC. There was no anastomosis in the pial or intrinsic networks. Only SupHypA, PCoA, ACoA, and ACA were involved in the OC blood supply. Because there was no extrinsic or intrinsic anastomosis, all arteries should be preserved. Tumor compression of the inferior intrinsic arterial network could contribute to visual defects. Clin. Anat. 31:432-440, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  2. Experimental cross sections for two-electron capture into nitrogen autoionising states in Nsup(q+) (q=6,7) on He and H/sub 2/ collisions at 10. 5q keV

    Energy Technology Data Exchange (ETDEWEB)

    Bordenave-Montesquieu, A.; Benoit-Cattin, P.; Gleizes, A.; Marrakchi, A.I.; Dousson, S.; Hitz, D.

    1985-07-01

    Singly differential cross sections for two-electron capture into autoionising states (nl,n'l') with n=2,3,4 and n'>=n in Nsup(q+) (q=6,7) on He and H/sub 2/ collisions have been measured at 10,5q ke V collision energy and an observation angle thetasub(lab)=11.6/sup 0/. Total cross sections are estimated assuming isotropic angular distributions. (orig.).

  3. A new hard X-ray transient discovered by INTEGRAL: IGR J17559-2612

    DEFF Research Database (Denmark)

    Esposito, V.; Ferrigno, C.; Bozzo, E.

    2012-01-01

    /ISGRI spectrum can be described (χ2red/d.o.f.=0.4 for 8 d.o.f.) by a power-law (Γ=1.6 ± 0.3, uncertainty at 90% c.l.). The 20-100 keV flux estimated from the spectral fit is 3.0 × 10-10 erg/s/cm2 (18 mCrab). Multi-wavelength follow-up observations are encouraged to unveil the nature of this transient.......V and the 40-80 keV energy bands. The corresponding fluxes are 11.9±1.4 mCrab and 17.5±2.1 mCrab (9.2±1.1 × 10-11 and 1.21±0.14 × 10-10 erg/s/cm2, uncertainties are at 68% c.l.). Due to off-axis pointing, the source is not detected in the combined mosaic of the two JEM-X units with a 3σ upper limits of 15...... and 20 mCrab in the 3-10 keV and 10-20 keV energy bands, respectively. The best source position determined with IBIS is RA= 268.99 (17h 55m 58s) Dec= -26.21 (-26d 12' 36") (J2000) with an associated pointing uncertainty of 3.5 arcmin at 90% c.l. (the Galactic coordinates are l= 3.515 b=-0.572). The IBIS...

  4. Delayed vertebral diagnosed L4 pincer vertebral fracture, L2-L3 ruptured vertebral lumbar disc hernia, L5 vertebral wedge fracture - Case report

    Directory of Open Access Journals (Sweden)

    Balasa D

    2016-08-01

    Full Text Available An association between delayed ruptured lumbar disc hernia, L5 vertebral wedge fracture and posttraumaticL4 pincer vertebral fracture (A2.3-AO clasification at different levels is a very rare entity. We present the case of a 55 years old male who falled down from a bicycle. 2 months later because of intense and permanent vertebral lumbar and radicular L2 and L3 pain (Visual Scal Autologus of Pain7-8/10 the patient came to the hospital. He was diagnosed with pincer vertebral L4 fracture (A2.3-AO clasification and L2-L3 right ruptured lumbar disc hernia in lateral reces. The patient was operated (L2-L3 right fenestration, and resection of lumbar disc hernia, bilateral stabilisation, L3-L4-L5 with titan screws and postero-lateral bone graft L4 bilateral harvested from iliac crest.

  5. Adductor Canal Block With 10 mL Versus 30 mL Local Anesthetics and Quadriceps Strength

    DEFF Research Database (Denmark)

    Jæger, Pia; Koscielniak-Nielsen, Zbigniew J; Hilsted, Karen Lisa

    2015-01-01

    weakness. METHODS: We performed a paired, blinded, randomized trial including healthy men. All subjects received bilateral ACBs with ropivacaine 0.1%; 10 mL in 1 leg and 30 mL in the other leg. The primary outcome was the difference in number of subjects with quadriceps strength reduced by more than 25...... of the predefined time points or in sensory block. The only statistically significant difference between volumes was found in the 30-Second Chair Stand Test at 2 hours (P = 0.02), but this difference had disappeared at 4 hours (P = 0.06). CONCLUSIONS: Varying the volume of ropivacaine 0.1% used for ACB between 10...

  6. Linac4 45 keV Proton Beam Measurements

    CERN Document Server

    Bellodi, G; Hein, L M; Lallement, J-B; Lombardi, A M; Midttun, O; Scrivens, R; Posocco, P A

    2013-01-01

    Linac4 is a 160 MeV normal-conducting H- linear accelerator, which will replace the 50 MeV proton Linac2 as injector for the CERN proton complex. Commissioning of the low energy part - comprising the H - source, a 45 keV Low Energy Beam Transport line (LEBT), a 3 MeV Radiofrequency Quadrupole (RFQ) and a Medium Energy Beam Transport (MEBT) - will start in fall 2012 on a dedicated test stand installation. In preparation to this, preliminary measurements were taken using a 45 keV proton source and a temporary LEBT setup, with the aim of characterising the output beam by comparison with the predictions of simulations. At the same time this allowed a first verification of the functionalities of diagnostics instrumentation and acquisition software tools. Measurements of beam profile, emittance and intensity were taken in three different setups: right after the source, after the first and after the second LEBT solenoids respectively. Particle distributions were reconstructed from emittance scan...

  7. Delayed vertebral diagnosed L4 pincer vertebral fracture, L2-L3 ruptured vertebral lumbar disc hernia, L5 vertebral wedge fracture - Case report

    OpenAIRE

    Balasa D; Schiopu M; Tunas A; Baz R; Hancu Anca

    2016-01-01

    An association between delayed ruptured lumbar disc hernia, L5 vertebral wedge fracture and posttraumaticL4 pincer vertebral fracture (A2.3-AO clasification) at different levels is a very rare entity. We present the case of a 55 years old male who falled down from a bicycle. 2 months later because of intense and permanent vertebral lumbar and radicular L2 and L3 pain (Visual Scal Autologus of Pain7-8/10) the patient came to the hospital. He was diagnosed with pincer vertebral L4 fracture (A2....

  8. Enhancement of L(+)-Lactic Acid Production of Immobilized Rhizopus Oryzae Implanted by Ion Beams

    International Nuclear Information System (INIS)

    Fan Yonghong; Yang Yingge; Zheng Zhiming; Li Wen; Wang Peng; Yao Liming; Yu Zengliang

    2008-01-01

    Immobilized Rhizopus oryzae culturing may be a solution to the inhibited production of L(+)-lactic acid in submerged fermentation, which is caused by aggregated mycelia floc. In the present study, a R. oryzae mutant (RL6041) with a 90% conversion rate of glucose into L-lactic acid was obtained by N + implantation under the optimized conditions of a beam energy of 15 keV and a dose of 2.6 x 10 15 ions/cm 2 . Using polyurethane foam as the immobilization matrix, the optimal L-lactic acid production conditions were determined as 4 mm polyurethane foam, 150 r/min, 50 g/L ∼ 80 g/L of initial glucose, 38 deg. C and pH 6.0. 15-cycle repeated productions of L-lactic acid by immobilized RL6041 were performed under the optimized culturing conditions and over 80% of the glucose was converted into L-lactic acid in 30 hours on average. The results show that immobilized RL6041 is a promising candidate for continuous L-lactic acid production.

  9. High accuracy measurement of the $^{235}$U(n,f) reaction cross-section in the 10-30 keV neutron energy range

    CERN Multimedia

    The analysis of the neutron flux of n_TOF (in EAR1) revealed an anomaly in the 10-30 keV neutron energy range. While the flux extracted on the basis of the $^{6}$Li(n,t)$^{4}$He and $^{10}$B(n,$\\alpha$)$^{7}$Li reactions mostly agreed with each other and with the results of FLUKA simulations of the neutron beam, the one based on the $^{235}$U(n,f) reaction was found to be systematically lower, independently of the detection system used. A possible explanation is that the $^{235}$U(n,f) crosssection in that energy region, where in principle should be known with an uncertainty of 1%, may be systematically overestimated. Such a finding, which has a negligible influence on thermal reactors, would be important for future fast critical or subcritical reactors. Furthermore, its interest is more general, since the $^{235}$U(n,f) reaction is often used at that energy to determine the neutron flux, or as reference in measurements of fission cross section of other actinides. We propose to perform a high-accuracy, high-r...

  10. Effects of uranium bombardment by 20-40 KeV argon ions, Annex 2

    International Nuclear Information System (INIS)

    Nenadovic, T.; Jurela, Z.

    1966-01-01

    This paper shows the results of argon ions interaction with the polycrystal natural uranium. Thin foil of uranium about 200 μ was bombarded by 20-40 KeV argon ions. Coefficients of cathode scattering δ and secondary electrons emission γ were measured, during the process A + →U. The foil was then studied by transmission method and method of single step replica using an electron microscope [sr

  11. First experiments with the 200 keV electron beam ion trap at LLNL

    International Nuclear Information System (INIS)

    Marrs, R.E.; Knapp, D.A.; Elliott, S.

    1993-01-01

    A high-energy electron beam ion trap (Super EBIT) is operating at electron energies up to 200 keV and currents up to 200 mA. Highly charged ions up to Li-like U 89+ and H-like Pb 81+ have been produced and studied. Ionization cross sections for H-like Dy 66+ at E e = 170 keV have been measured with respect to radiative recombination from the observed Dy 66+ /Dy 67+ equilibrium ionization balance. A Bragg crystal spectrometer has been used to measure 2s 1/2 -2p 3/2 transition energies in Li-like U 82+ with respect to the Lymann-series transitions in lower-Z hydrogenic ions

  12. 150 keV intense electron beam accelerator system with high repeated pulse

    International Nuclear Information System (INIS)

    Qi, Zhang; Tixing, Li; Hongfang, Tang; Nenggiao, Xia; Zhigin, Wang; Baohong, Zheng

    1993-01-01

    A 150 keV electron beam accelerator system has been developed for wide application of high power particle beams. The new wire-ion-plasma electron gun has been adopted. The parameters are as follows: Output energy - 130-150 keV; Electron beam density - 250 mA/cm 2 ; Pulse duration - 1 μs; Pulse rate 100 pps; Section of electron beam - 5 x 50 cm 2 . This equipment can be used to study repeated pulse CO 2 laser, to be a preionizer of high power discharge excimer laser and to perform radiation curing process, and so on. The first part contains principle and design consideration. Next is a description of experimental arrangement. The remainder is devoted to describing experimental results and its application

  13. Neutron capture cross sections of 69Ga and 71Ga at 25 keV and Epeak = 90 keV

    Science.gov (United States)

    Göbel, Kathrin; Beinrucker, Clemens; Erbacher, Philipp; Fiebiger, Stefan; Fonseca, Micaela; Heftrich, Michael; Heftrich, Tanja; Käppeler, Franz; Krása, Antonin; Lederer-Woods, Claudia; Plag, Ralf; Plompen, Arjan; Reifarth, René; Schmidt, Stefan; Sonnabend, Kerstin; Weigand, Mario

    2017-09-01

    We measured the neutron capture cross sections of 69Ga and 71Ga for a quasi-stellar spectrum at kBT = 25 keV and a spectrum with a peak energy at 90 keV by the activation technique at the Joint Research Centre (JRC) in Geel, Belgium. Protons were provided by an electrostatic Van de Graaff accelerator to produce neutrons via the reaction 7Li(p,n). The produced activity was measured via the γ emission of the product nuclei by high-purity germanium detectors. We present preliminary results.

  14. Total electron scattering cross sections of molecules containing H, C, N, O and F in the energy range 0.2–6.0 keV

    Energy Technology Data Exchange (ETDEWEB)

    Gurung, Meera Devi; Ariyasinghe, W.M., E-mail: wickram_ariyasinghe@baylor.edu

    2017-03-15

    Based on the effective atomic total electron scattering cross sections (EATCS) of atoms in a molecular environment, a simple model is proposed to predict the total electron scattering cross sections (TCS) of H, C, N, O, and F containing molecules. The EATCS for these five atoms are reported for 0.2–6.0 keV energies. The predicted TCS by this model are compared with experimental TCS in the literature. The experimental TCS of CHF{sub 3}, C{sub 2}F{sub 4}, C{sub 2}F{sub 2}H{sub 2}, C{sub 4}F{sub 6}, and c-C{sub 4}F{sub 8} have been obtained for 0.2–4.5 keV electrons by measuring the attenuation of the electron beam through a gas cell.

  15. Intrinsic Scene Decomposition from RGB-D Images

    KAUST Repository

    Hachama, Mohammed; Ghanem, Bernard; Wonka, Peter

    2015-01-01

    In this paper, we address the problem of computing an intrinsic decomposition of the colors of a surface into an albedo and a shading term. The surface is reconstructed from a single or multiple RGB-D images of a static scene obtained from different views. We thereby extend and improve existing works in the area of intrinsic image decomposition. In a variational framework, we formulate the problem as a minimization of an energy composed of two terms: a data term and a regularity term. The first term is related to the image formation process and expresses the relation between the albedo, the surface normals, and the incident illumination. We use an affine shading model, a combination of a Lambertian model, and an ambient lighting term. This model is relevant for Lambertian surfaces. When available, multiple views can be used to handle view-dependent non-Lambertian reflections. The second term contains an efficient combination of l2 and l1-regularizers on the illumination vector field and albedo respectively. Unlike most previous approaches, especially Retinex-like techniques, these terms do not depend on the image gradient or texture, thus reducing the mixing shading/reflectance artifacts and leading to better results. The obtained non-linear optimization problem is efficiently solved using a cyclic block coordinate descent algorithm. Our method outperforms a range of state-of-the-art algorithms on a popular benchmark dataset.

  16. Intrinsic Scene Decomposition from RGB-D Images

    KAUST Repository

    Hachama, Mohammed

    2015-12-07

    In this paper, we address the problem of computing an intrinsic decomposition of the colors of a surface into an albedo and a shading term. The surface is reconstructed from a single or multiple RGB-D images of a static scene obtained from different views. We thereby extend and improve existing works in the area of intrinsic image decomposition. In a variational framework, we formulate the problem as a minimization of an energy composed of two terms: a data term and a regularity term. The first term is related to the image formation process and expresses the relation between the albedo, the surface normals, and the incident illumination. We use an affine shading model, a combination of a Lambertian model, and an ambient lighting term. This model is relevant for Lambertian surfaces. When available, multiple views can be used to handle view-dependent non-Lambertian reflections. The second term contains an efficient combination of l2 and l1-regularizers on the illumination vector field and albedo respectively. Unlike most previous approaches, especially Retinex-like techniques, these terms do not depend on the image gradient or texture, thus reducing the mixing shading/reflectance artifacts and leading to better results. The obtained non-linear optimization problem is efficiently solved using a cyclic block coordinate descent algorithm. Our method outperforms a range of state-of-the-art algorithms on a popular benchmark dataset.

  17. Perturbation of angular correlations of 180-86 keV cascade in sup(155)G

    International Nuclear Information System (INIS)

    Budzynski, M; Lebedev, N.A.; Ljzurej, G.; Nezgoda, Kh.; Kochetov, O.I.; Muminov, A.I.; Khazratov, T.

    1980-01-01

    Using the differential disturbed angular correlation method attenuation of a correlation of the 180-86 keV cascade directions in 155 Gd has been studied. Coefficients of integral angular γγ-correlations for 155 Gd have been measured by an automatic correlation spectrometer with a Ge(Li) and two NaI(Tl) detectors. The obtained correlation coefficients are listed in a table. A fragment of the 155 Tb decay scheme, delayed-coincidence curves and a γ-spectrum are presented. During the analysis of experimental data on the differential disturbed angular correlation the nondisturbed correlation coefficient A 22 (O)=-0.220(4) for the 180-86 keV cascade has been obtained. Basing on this result the multipole composition of the 180 keV transition has been determined: M1+(3.54)% E2 with the mixing ratio delta=0.188. It has been found that at a low temperature strong attenuation of the 180-86 keV cascade angular correlation has been observed [ru

  18. Microsolvation of the acetanilide cation (AA(+)) in a nonpolar solvent: IR spectra of AA(+)-L(n) clusters (L = He, Ar, N2; n ≤ 10).

    Science.gov (United States)

    Schmies, Matthias; Patzer, Alexander; Schütz, Markus; Miyazaki, Mitsuhiko; Fujii, Masaaki; Dopfer, Otto

    2014-05-07

    Infrared photodissociation (IRPD) spectra of mass-selected cluster ions of acetanilide (N-phenylacetamide), AA(+)-Ln, with the ligands L = He (n = 1-2), Ar (n = 1-7), and N2 (n = 1-10) are recorded in the hydride stretch (amide A, νNH, νCH) and fingerprint (amide I-III) ranges of AA(+) in its (2)A'' ground electronic state. Cold AA(+)-Ln clusters are generated in an electron impact ion source, which predominantly produces the most stable isomer of a given cluster ion. Systematic vibrational frequency shifts of the N-H stretch fundamentals (νNH) provide detailed information about the sequential microsolvation process of AA(+) in a nonpolar (L = He and Ar) and quadrupolar (L = N2) solvent. In the most stable AA(+)-Ln clusters, the first ligand forms a hydrogen bond (H-bond) with the N-H proton of trans-AA(+) (t-AA(+)), whereas further ligands bind weakly to the aromatic ring (π-stacking). There is no experimental evidence for complexes with the less stable cis-AA(+) isomer. Quantum chemical calculations at the M06-2X/aug-cc-pVTZ level confirm the cluster growth sequence derived from the IR spectra. The calculated binding energies of De(H) = 720 and 1227 cm(-1) for H-bonded and De(π) = 585 and 715 cm(-1) for π-bonded Ar and N2 ligands in t-AA(+)-L are consistent with the observed photofragmentation branching ratios of AA(+)-Ln. Comparison between charged and neutral AA((+))-L dimers indicates that ionization switches the preferred ion-ligand binding motif from π-stacking to H-bonding. Electron removal from the HOMO of AA(+) delocalized over both the aromatic ring and the amide group significantly strengthens the C[double bond, length as m-dash]O bond and weakens the N-H bond of the amide group.

  19. Calculated and measured W values in N2, Ar, CH4 and CO2 gases for ions H+, He+, C+, N+, O+ and Ar+ in the energy range 25 KeV to 375 KeV

    International Nuclear Information System (INIS)

    Nguyen Van Dat; Chemtob, Maurice.

    1979-01-01

    The present paper describes the experimental method used for measurement of W values in argon gas and in the three components of T.E. gas: nitrogen, methane and carbon dioxide, for ions with masses in the range 1 to 40 a.m.u. and with energies in the range 25 KeV to 375 KeV. For these ions, the incident velocities are comparable to the electron orbital velocities. At these velocities energy losses due to elastic scattering and electron capture processes are expected to become significant as compared to ionization and excitation which predominate at higher velocities. These measured W values are then compared to calculated values. These calculations are obtained by introducing the inelastic and elastic stopping power cross sections in a transport equation, the resolution of which gives ionization range and the amount of energy released to produce ionization

  20. Analysis of 2H(d vector, p)3H reaction at 30-90 keV by four-body Faddeev-Yakubovsky equation

    International Nuclear Information System (INIS)

    Uzu, Eizo; Oryu, Shinsho; Tanifuji, Makoto.

    1993-01-01

    Low-energy 2 H(d vector, p) 3 H reactions are investigated by the four-body Faddeev-Yakubovsky equations. Cross sections and tensor analyzing powers are calculated at 30-90 keV energies. The PEST-1 potentials are used for nucleon-nucleon interactions. The [2+2] and [3+1] subamplitudes are treated by the Hilbert-Schmidt expansions. Numerical results give qualitative explanation of experimental data. (author)

  1. Evolution of nanodot morphology on polycarbonate (PC) surfaces by 40 keV Ar{sup +}

    Energy Technology Data Exchange (ETDEWEB)

    Goyal, Meetika, E-mail: meetika89@gmail.com; Chawla, Mahak; Gupta, Divya; Shekhawat, Nidhi; Sharma, Annu; Aggarwal, Sanjeev [Department of Physics, Kurukshetra University, Kurukshetra - 136119 (India)

    2016-05-06

    In the present paper we have discussed the effect of 40 keV Ar{sup +} ions irradiation on nanoscale surface morphology of Polycarbonate (PC) substrate. Specimens were sputtered at off normal incidences of 30°, 40° and 50° with the fluence of 1 × 10{sup 16} Ar{sup +}cm{sup −2}. The topographical behaviour of specimens was studied by using Atomic Force Microscopy (AFM) technique. AFM study demonstrates the evolution of nano dot morphology on PC specimens on irradiating with 1 × 10{sup 16} Ar{sup +}cm{sup −2}. Average size of dots varied from 37-95 nm in this specified range of incidence while density of dots varied from 0.17-3.0 × 107 dotscm{sup −2}. Such variations in morphological features have been supported by estimation of ion range and sputtering yield through SRIM simulations.

  2. The 27 Possible Intrinsic Symmetry Groups of Two-Component Links

    Directory of Open Access Journals (Sweden)

    Jason Parsley

    2012-02-01

    Full Text Available We consider the “intrinsic” symmetry group of a two-component link L, defined to be the image ∑(L of the natural homomorphism from the standard symmetry group MCG(S3, L to the product MCG(S3 × MCG(L. This group, first defined by Whitten in 1969, records directly whether L is isotopic to a link L′ obtained from L by permuting components or reversing orientations; it is a subgroup of Γ2, the group of all such operations. For two-component links, we catalog the 27 possible intrinsic symmetry groups, which represent the subgroups of Γ2 up to conjugacy. We are able to provide prime, nonsplit examples for 21 of these groups; some are classically known, some are new. We catalog the frequency at which each group appears among all 77,036 of the hyperbolic two-component links of 14 or fewer crossings in Thistlethwaite’s table. We also provide some new information about symmetry groups of the 293 non-hyperbolic two-component links of 14 or fewer crossings in the table.

  3. Measurement of the 238U(n ,γ ) cross section up to 80 keV with the Total Absorption Calorimeter at the CERN n_TOF facility

    Science.gov (United States)

    Wright, T.; Guerrero, C.; Billowes, J.; Cano-Ott, D.; Mendoza, E.; Altstadt, S.; Andrzejewski, J.; Audouin, L.; Bécares, V.; Barbagallo, M.; Bečvář, F.; Belloni, F.; Berthoumieux, E.; Bosnar, D.; Brugger, M.; Calviño, F.; Calviani, M.; Carrapiço, C.; Cerutti, F.; Chiaveri, E.; Chin, M.; Colonna, N.; Cortés, G.; Cortés-Giraldo, M. A.; Diakaki, M.; Dietz, M.; Domingo-Pardo, C.; Durán, I.; Dzysiuk, N.; Eleftheriadis, C.; Ferrari, A.; Fraval, K.; Furman, V.; Gómez-Hornillos, M. B.; Ganesan, S.; García, A. R.; Giubrone, G.; Gonçalves, I. F.; González-Romero, E.; Goverdovski, A.; Griesmayer, E.; Gunsing, F.; Gurusamy, P.; Heftrich, T.; Hernández-Prieto, A.; Jenkins, D. G.; Jericha, E.; Käppeler, F.; Kadi, Y.; Karadimos, D.; Katabuchi, T.; Ketlerov, V.; Khryachkov, V.; Koehler, P.; Kokkoris, M.; Kroll, J.; Krtička, M.; Lampoudis, C.; Langer, C.; Leal-Cidoncha, E.; Lederer, C.; Leeb, H.; Leong, L. S.; Lerendegui-Marco, J.; Losito, R.; Manousos, A.; Marganiec, J.; Martínez, T.; Massimi, C.; Mastinu, P.; Mengoni, A.; Milazzo, P. M.; Mingrone, F.; Mirea, M.; Paradela, C.; Pavlik, A.; Perkowski, J.; Praena, J.; Quesada, J. M.; Rauscher, T.; Reifarth, R.; Riego-Perez, A.; Robles, M.; Roman, F.; Rubbia, C.; Ryan, J. A.; Sabaté-Gilarte, M.; Sarmento, R.; Saxena, A.; Schillebeeckx, P.; Schmidt, S.; Schumann, D.; Sedyshev, P.; Tagliente, G.; Tain, J. L.; Tarifeño-Saldivia, A.; Tarrío, D.; Tassan-Got, L.; Tsinganis, A.; Valenta, S.; Vannini, G.; Variale, V.; Vaz, P.; Ventura, A.; Vermeulen, M. J.; Versaci, R.; Vlachoudis, V.; Vlastou, R.; Wallner, A.; Ware, T.; Weigand, M.; Weiss, C.; Žugec, P.; n TOF Collaboration

    2017-12-01

    The radiative capture cross section of a highly pure (99.999%), 6.125(2) grams and 9.56(5)×10-4 atoms/barn areal density 238U sample has been measured with the Total Absorption Calorimeter (TAC) in the 185 m flight path at the CERN neutron time-of-flight facility n_TOF. This measurement is in response to the NEA High Priority Request list, which demands an accuracy in this cross section of less than 3% below 25 keV. These data have undergone careful background subtraction, with special care being given to the background originating from neutrons scattered by the 238U sample. Pileup and dead-time effects have been corrected for. The measured cross section covers an energy range between 0.2 eV and 80 keV, with an accuracy that varies with neutron energy, being better than 4% below 25 keV and reaching at most 6% at higher energies.

  4. Intrinsic Motivation and Achievement in Mathematics in Elementary School: A Longitudinal Investigation of Their Association.

    Science.gov (United States)

    Garon-Carrier, Gabrielle; Boivin, Michel; Guay, Frédéric; Kovas, Yulia; Dionne, Ginette; Lemelin, Jean-Pascal; Séguin, Jean R; Vitaro, Frank; Tremblay, Richard E

    2016-01-01

    This study examined the associations between intrinsic motivation and achievement in mathematics in a sample of 1,478 Canadian school-age children followed from Grades 1 to 4 (ages 7-10). Children self-reported their intrinsic motivation toward mathematics, whereas achievement was measured through direct assessment of mathematics abilities. Cross-lagged models showed that achievement predicted intrinsic motivation from Grades 1 to 2, and from Grades 2 to 4. However, intrinsic motivation did not predict achievement at any time. This developmental pattern of association was gender invariant. Contrary to the hypothesis that motivation and achievement are reciprocally associated over time, our results point to a directional association from prior achievement to subsequent intrinsic motivation. Results are discussed in light of their theoretical and practical implications. © 2015 The Authors. Child Development © 2015 Society for Research in Child Development, Inc.

  5. Isolation and characterization of the TaSnRK2.10 gene and its association with agronomic traits in wheat (Triticum aestivum L..

    Directory of Open Access Journals (Sweden)

    Zhao-Gui Zhang

    Full Text Available Sucrose non-fermenting 1-related protein kinases (SnRKs comprise a major family of signaling genes in plants and are associated with metabolic regulation, nutrient utilization and stress responses. This gene family has been proposed to be involved in sucrose signaling. In the present study, we cloned three copies of the TaSnRK2.10 gene from bread wheat on chromosomes 4A, 4B and 4D. The coding sequence (CDS is 1086 bp in length and encodes a protein of 361 amino acids that exhibits functional domains shared with SnRK2s. Based on the haplotypes of TaSnRK2.10-4A (Hap-4A-H and Hap-4A-L, a cleaved amplified polymorphic sequence (CAPS marker designated TaSnRK2.10-4A-CAPS was developed and mapped between the markers D-1092101 and D-100014232 using a set of recombinant inbred lines (RILs. The TaSnRK2.10-4B alleles (Hap-4B-G and Hap-4B-A were transformed into allele-specific PCR (AS-PCR markers TaSnRK2.10-4B-AS1 and TaSnRK2.10-4B-AS2, which were located between the markers D-1281577 and S-1862758. No diversity was found for TaSnRK2.10-4D. An association analysis using a natural population consisting of 128 winter wheat varieties in multiple environments showed that the thousand grain weight (TGW and spike length (SL of Hap-4A-H were significantly higher than those of Hap-4A-L, but pant height (PH was significantly lower.

  6. Development of an X-ray imaging system within 10-30 keV spectral range based on organic or inorganic scintillator

    International Nuclear Information System (INIS)

    Turk, G.

    2011-01-01

    This thesis aims at developing an x-ray imaging system intended for the Laser Mega Joule, within the framework of Inertial Confinement Fusion (ICF) experiments. ICF aims at yielding thermonuclear energy through laser-driven fusion of a deuterium-tritium mix. The operational function of our system is to acquire an image of the 10-30 keV x-rays emitted by the maximally compressed micro-balloon, with spatial resolution better than 10 μm. The presented system is only a part of a complete diagnostic system, which normally includes an x-ray optical subsystem. Our system conception largely takes vulnerability into account. The ignition phase of ICF yields 10 16 neutrons, with energies scaling up to 14 MeV. The neutrons generate such a hard surrounding with effects scaling down from image degradation up to instrumentation destruction. The presented system consists in a scintillator which is focused on a CCD camera through a catadioptric image transport system. An innovation work has been lead on scintillators to provide an answer to specifications greatly influenced by vulnerability. Those thesis works lead to an imaging system allowing to deport the CCD camera by 4 meters from the scintillator, with 100 μm spatial resolution in the scintillator plane. Those works have paved the way to outlooks such as enhancement of organic loaded scintillators compositions and improvement of optical relay system. (author) [fr

  7. MRI Evaluation of Non-Necrotic T2-Hyperintense Foci in Pediatric Diffuse Intrinsic Pontine Glioma.

    Science.gov (United States)

    Clerk-Lamalice, O; Reddick, W E; Li, X; Li, Y; Edwards, A; Glass, J O; Patay, Z

    2016-05-19

    The conventional MR imaging appearance of diffuse intrinsic pontine glioma suggests intralesional histopathologic heterogeneity, and various distinct lesion components, including T2-hypointense foci, have been described. Here we report the prevalence, conventional MR imaging semiology, and advanced MR imaging features of non-necrotic T2-hyperintense foci in diffuse intrinsic pontine glioma. Twenty-five patients with diffuse intrinsic pontine gliomas were included in this study. MR imaging was performed at 3T by using conventional and advanced MR imaging sequences. Perfusion (CBV), vascular permeability (v e , K trans ), and diffusion (ADC) metrics were calculated and used to characterize non-necrotic T2-hyperintense foci in comparison with other lesion components, namely necrotic T2-hyperintense foci, T2-hypointense foci, peritumoral edema, and normal brain stem. Statistical analysis was performed by using Kruskal-Wallis and Wilcoxon rank sum tests. Sixteen non-necrotic T2-hyperintense foci were found in 12 tumors. In these foci, ADC values were significantly higher than those in either T2-hypointense foci (P = .002) or normal parenchyma (P = .0002), and relative CBV values were significantly lower than those in either T2-hypointense (P = .0002) or necrotic T2-hyperintense (P = .006) foci. Volume transfer coefficient values in T2-hyperintense foci were lower than those in T2-hypointense (P = .0005) or necrotic T2-hyperintense (P = .0348) foci. Non-necrotic T2-hyperintense foci are common, distinct lesion components within diffuse intrinsic pontine gliomas. Advanced MR imaging data suggest low cellularity and an early stage of angioneogenesis with leaky vessels resulting in expansion of the extracellular space. Because of the lack of biopsy validation, the underlying histoarchitectural and pathophysiologic changes remain unclear; therefore, these foci may correspond to a poorly understood biologic event in tumor evolution. © 2016 American Society of Neuroradiology.

  8. Differential cross sections for single ionization of H2 by 75-keV proton impact

    International Nuclear Information System (INIS)

    Chowdhury, U.; Schulz, M.; Madison, D. H.

    2011-01-01

    We have calculated triply differential cross sections (TDCS) and doubly differential cross sections (DDCS) for single ionization of H 2 by 75-keV proton impact using the molecular three-body distorted-wave-eikonal initial-state (M3DW-EIS) approach. Previously published measured DDCS (differential in the projectile scattering angle and integrated over the ejected electron angles) found pronounced structures at relatively large angles that were interpreted as an interference resulting from the two-centered potential of the molecule. Theory treating H 2 as atomic H multiplied by a molecular interference factor only predicts the observed structure when assumptions are made about the molecular orientation. Here we apply the M3DW-EIS method, which does not rely on such an ad hoc approach, but rather treats the interference from first principles.

  9. Angular dependence of Ll, L $\\alpha$ , L $\\beta$ and L $\\gamma$ X-ray differential and fluorescence cross-sections for Er, Ta, W, Au, Hg and Tl

    CERN Document Server

    Demir, L; Kurucu, Y; Karabulut, A; Sahin, Y; 10.1016/S0969-806X(02)00501-7

    2003-01-01

    Ll, L alpha , L beta and L gamma X-ray differential cross-sections, fluorescence cross-sections and L/sub i/-subshell ( sigma /sub L1/, sigma /sub L2/, and sigma /sub L3/) fluorescence cross-sections were measured for Er, Ta, W, Au, Hg, and Tl at an excitation energy of 59.6 keV using a Si(Li) detector. The differential cross-sections for these elements have been measured at different angles varying from 54 degrees to 153 degrees at intervals of 9 degrees . The Ll and L alpha groups in the L X-ray lines are found to be spatially anisotropic, while those in the L beta and L gamma peaks are isotropic. Experimental and theoretical values of L X-ray fluorescence cross- sections and L/sub i/-subshell X-ray fluorescence cross-sections were compared. (20 refs).

  10. Atomistic modeling of L10 FePt: path to HAMR 5Tb/in2

    Science.gov (United States)

    Chen, Tianran; Benakli, Mourad; Rea, Chris

    2015-03-01

    Heat assisted magnetic recording (HAMR) is a promising approach for increasing the storage density of hard disk drives. To increase data density, information must be written in small grains, which requires materials with high anisotropy energy such as L10 FePt. On the other hand, high anisotropy implies high coercivity, making it difficult to write the data with existing recording heads. This issue can be overcome by the technique of HAMR, where a laser is used to heat the recording medium to reduce its coercivity while retaining good thermal stability at room temperature due to the large anisotropy energy. One of the keys to the success of HAMR is the precise control of writing process. In this talk, I will propose a Monte Carlo simulation, based on an atomistic model, that would allow us to study the magnetic properties of L10 FePt and dynamics of spin reversal for the writing process in HAMR.

  11. Sputtering of thin and intermediately thick films of solid deuterium by keV electrons

    DEFF Research Database (Denmark)

    Svendsen, Winnie Edith; Thestrup Nielsen, Birgitte; Schou, Jørgen

    1995-01-01

    Sputtering of films of solid deuterium by keV electrons was studied in a cryogenic set-up. The sputtering yield shows a minimum yield of about 4 D2/electron for 1.5 and 2 keV electrons at a thickness slightly larger than the average projected range of the electrons. We suggest that the yield around...... the minimum represents the value closest to a bulk-yield induced by electron bombardment. It may also include contributions from the mechanisms that enhance the yield for thin and very thick films....

  12. Reflectance spectroscopy of PMMA implanted with 50 keV silicon ions

    Energy Technology Data Exchange (ETDEWEB)

    Florian, Bojana [Bulgarian Institute of Metrology, 2 Prof. P. Mutafchiev Str., 1797 Sofia (Bulgaria); Stefanov, Ivan [Department of Quantum Electronics, Faculty of Physics, Sofia University, 5 James Bourchier Blvd., 1164 Sofia (Bulgaria); Hadjichristov, Georgi [Institute of Solid State Physics, 72 Tzarigradsko Chaussee Blvd., 1784 Sofia (Bulgaria)

    2009-07-01

    Recently, the modification of the specular reflectivity of PMMA implanted with low-energy (50 keV) silicon ions was studied and nano-clusters formed in PMMA by Si{sup +} implantation were evidenced by Raman spectroscopy and electrical measurements. Further, the optical loss due to off-specular (diffuse) reflectivity of this ion-implanted polymer is also of practical interest for applications such as micro-optical lenses, diffraction gratings, Fresnel lenses, waveguides, etc. We examined both specular and diffuse reflectivity of Si{sup +} implanted PMMA in the UV-Vis-NIR. The effect from Si{sup +} implantation in the dose range 10{sup 14}-10{sup 17} ions/cm{sup 2} is linked to the structure formed in PMMA where the buried ion-implanted layer has a thickness up to 100 nm. As compared to the pristine PMMA, an enhancement of the reflectivity of Si{sup +} implanted PMMA is observed, that is attributed to the modification of the subsurface region of PMMA upon the ion implantation.

  13. Sputtering characteristics of B4C-overlaid graphite for keV energy deuterium ion irradiation

    International Nuclear Information System (INIS)

    Gotoh, Y.; Yamaki, T.; Ando, T.; Jimbou, R.; Ogiwara, N.; Saidoh, M.; Teruyama, K.

    1992-01-01

    Two types of B 4 C-overlaid graphite (CFC), conversion and CVD B 4 C, together with bare CFC (PCC-2S) and/or HP B 4 C, were investigated with respect to erosion yields for 1 keV D + , D 2 /CD 4 TDS after 1 keV D + implantation, and thermal diffusivity/conductivity, in a temperature range from 300 to 1400 K. The erosion yields of both conversion and CVD B 4 C were found to be much lower than that of the bare CFC (PCC-2S), in both chemical sputtering (600-1100 K) and RES (1200-1400 K) temperature regions. The D 2 TDS peak of the conversion B 4 C was found to be located at nearly 200 K lower temperature than that of the bare CFC (PCC-2S), indicating much lower activation energy for detrapping/recombination of trapped D in the conversion B 4 C and in the CFC. The CD 4 TDS peak of the conversion B 4 C was found to be much weaker in intensity than that of the bare CFC (PCC-2S), in agreement with the present erosion yield results. Thermal diffusivities and conductivities of both the conversion B 4 C/PCC-2S and the CVD B 4 C, were measured to be nearly 1/10 of that of the bare CFC (PCC-2S), and to decrease with increasing temperatures. (orig.)

  14. INTRINSIC TOPOLOGY AND REFINEMENT OF HUTTON UNIT INTERVAL

    Institute of Scientific and Technical Information of China (English)

    王国俊; 徐罗山

    1992-01-01

    This paper introduces the theory of continuous lattices to the study of the Hutton unit interval I(L). some theorems related to I(L) are pithily proved. A kind of intrinsic topologies is applied to refining the topology of I(L),and a new fuzzy unit interval,called the H(λ) unit interval,is defined.Based on the H(λ) unit interval the H(λ)-complete regularity is introduced.Also,the theory of. H(λ)-stone-ech compactifications is established

  15. The intrinsic cephalosporin resistome of Listeria monocytogenes in the context of stress response, gene regulation, pathogenesis and therapeutics.

    Science.gov (United States)

    Krawczyk-Balska, A; Markiewicz, Z

    2016-02-01

    Intrinsic resistance to antibiotics is a serious therapeutic problem in the case of many bacterial species. The Gram-positive human pathogen Listeria monocytogenes is intrinsically resistant to broad spectrum cephalosporin antibiotics, which are commonly used in therapy of bacterial infections. Besides three penicillin-binding proteins the intrinsic cephalosporin resistome of L. monocytogenes includes multidrug resistance transporter transporters, proteins involved in peptidoglycan biosynthesis and modification, cell envelope proteins with structural or general detoxification function, cytoplasmic proteins with unknown function and regulatory proteins. Analysis of the regulation of the expression of genes involved in the intrinsic resistance of L. monocytogenes to cephalosporins highlights the high complexity of control of the intrinsic resistance phenotype. The regulation of the transcription of the intrinsic resistome determinants involves the activity of eight regulators, namely LisR, CesR, LiaR, VirR, σ(B) , σ(H) , σ(L) and PrfA, of which the most prominent role play LisR, CesR and σ(B) . Furthermore, the vast majority of the intrinsic resistome determinants contribute to the tolerance of different stress conditions and virulence. A study indicates that O-acetyltransferase OatA is the most promising candidate for co-drug development since an agent targeting OatA should sensitize L. monocytogenes to certain antibiotics, therefore improving the efficacy of listeriosis treatment as well as food preservation measures. © 2015 The Society for Applied Microbiology.

  16. Trichloroethylene metabolite S-(1,2-dichlorovinyl)-l-cysteine induces lipid peroxidation-associated apoptosis via the intrinsic and extrinsic apoptosis pathways in a first-trimester placental cell line.

    Science.gov (United States)

    Elkin, Elana R; Harris, Sean M; Loch-Caruso, Rita

    2018-01-01

    Trichloroethylene (TCE), a prevalent environmental contaminant, is a potent renal and hepatic toxicant through metabolites such as S-(1, 2-dichlorovinyl)-l-cysteine (DCVC). However, effects of TCE on other target organs such as the placenta have been minimally explored. Because elevated apoptosis and lipid peroxidation in placenta have been observed in pregnancy morbidities involving poor placentation, we evaluated the effects of DCVC exposure on apoptosis and lipid peroxidation in a human extravillous trophoblast cell line, HTR-8/SVneo. We exposed the cells in vitro to 10-100μM DCVC for various time points up to 24h. Following exposure, we measured apoptosis using flow cytometry, caspase activity using luminescence assays, gene expression using qRT-PCR, and lipid peroxidation using a malondialdehyde quantification assay. DCVC significantly increased apoptosis in time- and concentration-dependent manners (p<0.05). DCVC also significantly stimulated caspase 3, 7, 8 and 9 activities after 12h (p<0.05), suggesting that DCVC stimulates the activation of both the intrinsic and extrinsic apoptotic signaling pathways simultaneously. Pre-treatment with the tBID inhibitor Bl-6C9 partially reduced DCVC-stimulated caspase 3 and 7 activity, signifying crosstalk between the two pathways. Additionally, DCVC treatment increased lipid peroxidation in a concentration-dependent manner. Co-treatment with the antioxidant peroxyl radical scavenger (±)-α-tocopherol attenuated caspase 3 and 7 activity, suggesting that lipid peroxidation mediates DCVC-induced apoptosis in extravillous trophoblasts. Our findings suggest that DCVC-induced apoptosis and lipid peroxidation in extravillous trophoblasts could contribute to poor placentation if similar effects occur in vivo in response to TCE exposure, indicating that further studies into this mechanism are warranted. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Characteristic K-shell x-ray production by protons below 500 keV

    International Nuclear Information System (INIS)

    Wheeler, R.M.; Chaturvedi, R.P.; Zander, A.R.

    1974-01-01

    The total thick target yield of K-shell x-rays produced in Ni by incident protons over the energy range 90 to 415 keV was measured. Similar measurements with 130 to 415 keV protons were made for Ti, Mn, Fe, Cu, and Zn. The East Texas State University 150 keV Cockcroft--Walton accelerator was used to study Ni K-shell x-rays produced by 90 to 150 keV protons. The remaining data were taken with the SUNY College at Cortland 400 keV Van de Graaff generator. The characteristic x-rays were measured with high resolution Si(Li) detectors. Using the most recent values of K-shell fluorescent yields, x-ray ionization cross sections were calculated and compared to theoretical predictions based on the binary encounter approximation (BEA) model. It was found that even though the data were lower than those expected by the BEA theory, they lie on a universal curve. A comprehensive summary of x-ray ionization cross section references covering the proton energy range up to 500 keV is also included. Possible applications of low energy accelerators (E/sub p/ less than or equal to 500 keV) for further experimental work is discussed

  18. Measurement of the ratio of double-to-single photoionization of helium at 2.8 keV using synchrotron radiation

    International Nuclear Information System (INIS)

    Levin, J.C.; Lindle, D.W.; Keller, N.; Miller, R.D.; Azuma, Y.; Mansour, N.B.; Berry, H.G.; Sellin, I.A.

    1991-01-01

    We report the first measurement of the ratio of double-to-single photoionization of helium well above the double-ionization threshold. Using a time-of-flight technique, we find He ++ /He + =1.6±0.3% at hν=2.8 keV. This value lies between calculations by Amusia (2.3%) and by Samson, who predicts 1.2% by analogy with electron-impact ionization cross sections of singly charged ions. Good agreement is obtained with older shake calculations of Byron and Joachain, and of Aberg, who predict 1.7%

  19. Properties of the transitions populating and depopulating the 279 keV level in /sup 75/As

    Energy Technology Data Exchange (ETDEWEB)

    Puri, V S; Khurana, C S; Sahota, H S [Punjabi Univ., Patiala (India). Nuclear Science Labs.

    1977-09-01

    The low-energy gamma-ray spectrum of /sup 75/As from /sup 75/Sc has been investigated using a 6 mm x 6 mm Si(Li) spectrometer. The intensity of the 24.4 keV transition has been found to be 0.07 +- 0.01. No evidence has been found for the presence of a 14.9 keV transition. From directional correlation measurements involving the 24.4 keV transition detected in the Si(Li) detector, the multipolarity of this transition has been found to be delta(E3/M2)sub(24.4) =0.18 +- 0.02. The internal conversion process of the 279 keV transition seems to be normal. No effect of the chemical environment has been observed on the (121 ..gamma..-279..gamma..) directional correlation coefficients.

  20. Comparing Intrinsic Connectivity Models for the Primary Auditory Cortices

    Science.gov (United States)

    Hamid, Khairiah Abdul; Yusoff, Ahmad Nazlim; Mohamad, Mazlyfarina; Hamid, Aini Ismafairus Abd; Manan, Hanani Abd

    2010-07-01

    This fMRI study is about modeling the intrinsic connectivity between Heschl' gyrus (HG) and superior temporal gyrus (STG) in human primary auditory cortices. Ten healthy male subjects participated and required to listen to white noise stimulus during the fMRI scans. Two intrinsic connectivity models comprising bilateral HG and STG were constructed using statistical parametric mapping (SPM) and dynamic causal modeling (DCM). Group Bayes factor (GBF), positive evidence ratio (PER) and Bayesian model selection (BMS) for group studies were used in model comparison. Group results indicated significant bilateral asymmetrical activation (puncorr < 0.001) in HG and STG. Comparison results showed strong evidence of Model 2 as the preferred model (STG as the input center) with GBF value of 5.77 × 1073 The model is preferred by 6 out of 10 subjects. The results were supported by BMS results for group studies. One-sample t-test on connection values obtained from Model 2 indicates unidirectional parallel connections from STG to bilateral HG (p<0.05). Model 2 was determined to be the most probable intrinsic connectivity model between bilateral HG and STG when listening to white noise.

  1. Resonance parameters for measured keV neutron capture cross sections

    Energy Technology Data Exchange (ETDEWEB)

    Musgrove, A.R. de L

    1969-05-01

    All available neutron capture cross sections in the keV region ({approx} to 100 keV) have been fitted with resonance parameters. Capture cross sections for nuclides with reasonably well known average s-wave parameters, but no measured cross section, have been calculated and tabulated using p-and d- wave strength functions interpolated between fitted values. Several of these nuclides are of interest in the theory of slow nucleosynthesis of heavy elements in stars, and the product of cosmic abundance (due to the s-process) and capture cross section at 30 keV has been plotted versus mass number. (author)

  2. Population of the 283 keV level of 137Ba by the β decay of 137Cs

    International Nuclear Information System (INIS)

    Bikit, I.; Anicin, I.; Slivka, J.; Krmar, M.; Puzovic, J.; Conkic, L.

    1996-01-01

    The gamma spectrum of 137 Cs was measured by means of a low-level shielded and Compton-suppressed HpGe spectrometer. The gamma line with the energy 283.4 keV and absolute intensity of 5.3(14)x10 -6 was found. It was concluded that the 283.4 keV intermediate level in 137 Ba [seen earlier in (n,n'γ) measurements] is populated in the β decay of 137 Cs with the comparative half-life of logft=15.3(3). copyright 1996 The American Physical Society

  3. Absolute M1 and E2 Transition Probabilities in 233U

    International Nuclear Information System (INIS)

    Malmskog, S.G.; Hoejeberg, M.

    1967-08-01

    Using the delayed coincidence technique, the following half lives have been determined for different excited states in 233 U: T 1/2 (311.9 keV level) = (1.20 ± 0.15) x 10 -10 sec, T 1/2 (340.5 keV level) = (5.2 ± 1.0) x 10 -11 sec, T 1/2 (398.6 keV level) = (5.5 ± 2.0) x 10 -11 sec and T 1/2 (415.8 keV level) -11 sec. From these half life determinations, together with earlier known electron intensities and conversion coefficients, 22 reduced B(Ml) and B(E2) transition probabilities (including 9 limits) have been deduced. The rotational transitions give information on the parameters δ and (g K - g R ) . The experimental M1 and E2 transition rates between members of different bands have been analysed in terms of the predictions of the Nilsson model, taking also pairing correlations and Coriolis coupling effects into account

  4. Shifting of the electron-capture-to-the-continuum peak in proton-helium collisions at 10 and 20 keV

    International Nuclear Information System (INIS)

    Bhattacharya, S.; Deb, N.C.; Roy, K.; Sahoo, S.; Crothers, D.S.F.

    2005-01-01

    A refined theoretical approach has been developed to study the double-differential cross sections (DDCS's) in proton-helium collisions as a function of the ratio of ionized electron velocity to the incident proton velocity. The refinement is done in the present coupled-channel calculation by introducing a continuum distorted wave in the final state coupled with discrete states including direct as well as charge transfer channels. It is confirmed that the electron-capture-to-the-continuum (ECC) peak is slightly shifted to a lower electron velocity than the equivelocity position. Comparing measurements and classical trajectory Monte Carlo (CTMC) calculations at 10 and 20 keV proton energies, excellent agreement of the ECC peak heights is achieved at both energies. However, a minor disagreement in the peak positions between the present calculation and the CTMC results is noted. A smooth behavior of the DDCS is found in the present calculation on both sides of the peak whereas the CTMC results show some oscillatory behavior particularly to the left of the peak, associated with the statistical nature of CTMC calculations

  5. Regulation of Intrinsic and Extrinsic Apoptotic Pathways in Osteosarcoma Cells Following Oleandrin Treatment.

    Science.gov (United States)

    Ma, Yunlong; Zhu, Bin; Yong, Lei; Song, Chunyu; Liu, Xiao; Yu, Huilei; Wang, Peng; Liu, Zhongjun; Liu, Xiaoguang

    2016-11-23

    Our previous study has reported the anti-tumor effect of oleandrin on osteosarcoma (OS) cells. In the current study, we mainly explored its potential regulation on intrinsic and extrinsic apoptotic pathway in OS cells. Cells apoptosis, reactive oxygen species (ROS) and mitochondrial membrane potential (MMP) were detected using fluorescence staining and flow cytometry. Caspase-3 activity was detected using a commercial kit. The levels of cytoplasmic cytochrome c, mitochondrial cytochrome c, bcl-2, bax, caspase-9, Fas, FasL, caspase-8 and caspase-3 were detected by Western blotting. z-VAD-fmk was applied to block both intrinsic and extrinsic apoptosis pathways, and cells apoptosis was also tested. Furthermore, we used z-LEHD-fmk and Fas blocking antibody to inhibit intrinsic and extrinsic pathways, separately, and the selectivity of oleandrin on these pathways was explored. Results showed that oleandrin induced the apoptosis of OS cells, which was accompanied by an increase in ROS and a decrease in MMP. Furthermore, cytochrome c level was reduced in mitochondria but elevated in the cytoplasm. Caspase-3 activity was enhanced by oleandrin in a concentration- and time-dependent manner. Oleandrin also down-regulated the expression of bcl-2, but up-regulated bax, caspase-9, Fas, FasL, caspase-8 and caspase-3. In addition, the suppression of both apoptotic pathways by z-VAD-fmk greatly reverted the oleandrin-induced apoptosis. Moreover, the suppression of one pathway by a corresponding inhibitor did not affect the regulation of oleandrin on another pathway. Taken together, we concluded that oleandrin induced apoptosis of OS cells via activating both intrinsic and extrinsic apoptotic pathways.

  6. A study of the higher excitation levels of 11B via the 10B(n,n)10B and 10B(n,n')10B*(0.72, 1.74, 2.15, 3.59, 4.77 MeV) reactions

    International Nuclear Information System (INIS)

    Sadowski, E.T.

    1988-11-01

    As part of the study of the higher energy-level structure of 11 B, cross sections for elastic and inelastic scattering of neutrons from isotopically enriched 10 B samples have been measured for incident neutron energies from 3.03 MeV to 6.45 MeV in 250 keV increments and from 7.02 MeV to 12.01 MeV in 500 keV increments. Inelastic angular distributions for scattering to the states in parentheses in 10 B have been measured from the indicated energy up to 12.01 MeV; (0.718) from 3.02 MeV; (1.74) from 3.27 MeV; (2.15) from 3.77 MeV; (3.59) from 5.52 MeV; (4.77) from 7.02 MeV. The measurements at 3.02, 3.51, 4.02, and 4.51 MeV were done at nine laboratory angles from 20/degree/ to 158/degree/ in 17.5/degree/ increments with a sample that is isotopically 95.86% 10 B. All other distributions measured scattering at 11 laboratory angles from 18/degree/ to 158/degree/ in 15/degree/ increments from a sample that is isotopically 99.49% 10 B. The data are corrected for air scattering, sample attenuation, minor isotope impurity, multiple scattering, and elastic and inelastic scattering from the sample of the neutron source continuum and contaminants. An eight-channel, multilevel R-matrix analysis was performed on the data. Level energies, spins, and parities were deduced for twelve levels above 13 MeV excitation in 11 B. Only two definite and three tentative assignments for T = /1/2/ levels had been made previously above 13 MeV. The two definite levels were confirmed. Good agreement between the data and the R-matrix calculation in all analyzed channels was obtained for the proposed structure. 122 refs., 40 figs., 7 tabs

  7. A 600 keV electron radiation accelerator

    International Nuclear Information System (INIS)

    Zhou Youyi; Wang Xurong

    1995-01-01

    The authors describe a 600 keV two-body multi-functional electron and positive ion radiation accelerator based on a 400 keV Cockroft-Walton, Which was successfully used to accelerate electron and positive ion. Through test on coating solidification of decoration materials, such as colorful surface plaster plate and relief plate, and researches on metal plate, plastic plate, wood and paper coating decorations and radiation workmanship, as well as experiment of brach-linking by radiation for filling materials of petroleum pipings, it is proved that the device is reliable and stable in operation and reaches the pre-set design indexes and satisfies the requirements called for

  8. Calibration of hard x-ray (15 - 50 keV) optics at the MPE test facility PANTER

    Science.gov (United States)

    Bräuninger, Heinrich; Burkert, Wolfgang; Hartner, Gisela D.; Citterio, Oberto; Ghigo, Mauro; Mazzoleni, Francesco; Pareschi, Giovanni; Spiga, Daniele

    2004-02-01

    The Max-Planck-Institut für extraterrestrische Physik (MPE) in Garching, Germany, operates the large X-ray beam line facility PANTER for testing astronomical systems. At PANTER a number of telescopes like EXOSAT, ROSAT, SAX, JET-X, ABRIXAS, XMM and SWIFT operating in the soft energy range (0.02 - 15 keV) have been successfully calibrated. In the present paper we report on an important upgrade recently implemented that enables the calibration of hard X-ray optics (from 15 up to 50 keV). Currently hard X-ray optics based on single and multilayer coating are being developed for several future X-ray missions. The hard X-ray calibrations at PANTER are carried out by a high energy source based on an electron gun and several anodes, able to cover the energy range from 4.5 up to 50 keV. It provides fluxes up to 104 counts/sec/cm2 at the instrument chamber with a stability better than 1%. As detector a pn-CCD camera operating between 0.2 and 50 keV and a collecting area of 36 cm2 is used. Taking into account the high energy resolution of the CCD (145 eV at 6 keV), a very easy way to operate the facility in hard X-ray is in energy-dispersive mode (i.e. with a broad-band beam). A double crystal monochromator is also available providing energies up to 20 keV. In this paper we present the first results obtained by using PANTER for hard X-ray characterizations, performed on prototype multilayer optics developed by the Osservatorio Astronomico di Brera (OAB), Milano, Italy, and the Harvard-Smithsonian Center for Astrophysics (CfA), Cambridge, MA, USA.

  9. Resolved resonance parameters for uranium 238 from 4 to 6 keV

    International Nuclear Information System (INIS)

    Olsen, D.K.; Meszaros, P.S.

    1982-01-01

    Neutron widths for 145 resonances from 4 to 6 keV are reported from a least-squares shape analysis of the ORELA 150-m, 4-sample 238 U transmission data. The resultant s-wave strength function from 4 to 6 keV is found to be substantially smaller than that from 0 to 4 keV

  10. Geometrical neutrino mass hierarchy and a 17-keV ντ

    International Nuclear Information System (INIS)

    Babu, K.S.; Mohapatra, R.N.

    1991-01-01

    We present an extension of the singlet majoron gauge model which realizes a novel scheme of geometrical neutrino mass hierarchy proposed recently by Glashow, wherein ν e and ν μ are Majorana particles with m νe ∼m νμ ∼10 -3 eV while ν τ is a Dirac particle with a mass of 17 keV. Our model explains the solar-neutrino deficit via the Mikheyev-Smirnov-Wolfenstein mechanism and accounts for the recently reported anomaly in beta-decay spectra in a natural manner without any undesirable fine tuning of parameters. An interesting consequence of the model is that ν τ is short lived with a lifetime of ∼10 -3-- 10 -1 sec

  11. The antituberculosis antibiotic capreomycin inhibits protein synthesis by disrupting interaction between ribosomal proteins L12 and L10.

    Science.gov (United States)

    Lin, Yuan; Li, Yan; Zhu, Ningyu; Han, Yanxing; Jiang, Wei; Wang, Yanchang; Si, Shuyi; Jiang, Jiandong

    2014-01-01

    Capreomycin is a second-line drug for multiple-drug-resistant tuberculosis (TB). However, with increased use in clinics, the therapeutic efficiency of capreomycin is decreasing. To better understand TB resistance to capreomycin, we have done research to identify the molecular target of capreomycin. Mycobacterium tuberculosis ribosomal proteins L12 and L10 interact with each other and constitute the stalk of the 50S ribosomal subunit, which recruits initiation and elongation factors during translation. Hence, the L12-L10 interaction is considered to be essential for ribosomal function and protein synthesis. Here we provide evidence showing that capreomycin inhibits the L12-L10 interaction by using an established L12-L10 interaction assay. Overexpression of L12 and/or L10 in M. smegmatis, a species close to M. tuberculosis, increases the MIC of capreomycin. Moreover, both elongation factor G-dependent GTPase activity and ribosome-mediated protein synthesis are inhibited by capreomycin. When protein synthesis was blocked with thiostrepton, however, the bactericidal activity of capreomycin was restrained. All of these results suggest that capreomycin seems to inhibit TB by interrupting the L12-L10 interaction. This finding might provide novel clues for anti-TB drug discovery.

  12. L2 Working Memory Capacity and L2 Reading Skill.

    Science.gov (United States)

    Harrington, Mike; Sawyer, Mark

    1992-01-01

    Examines the sensitivity of second-language (L2) working memory (ability to store and process information simultaneously) to differences in reading skills among advanced L2 learners. Subjects with larger L2 working memory capacities scored higher on measures of L2 reading skills, but no correlation was found between reading and passive short-term…

  13. Intrinsic stress of bismuth oxide thin films: effect of vapour chopping and air ageing

    International Nuclear Information System (INIS)

    Patil, R B; Puri, R K; Puri, V

    2008-01-01

    Bismuth oxide thin films of thickness 1000 A 0 have been prepared by thermal oxidation (in air) of vacuum evaporated bismuth thin films (on glass substrate) at different oxidation temperatures and duration. Both the vapour chopped and nonchopped bismuth oxide thin films showed polycrystalline and polymorphic structure. The monoclinic bismuth oxide was found to be predominant in both the cases. The effect of vapour chopping and air exposure for 40 days on the intrinsic stress of bismuth oxide thin films has been studied. The vapour chopped films showed low (3.92 - 4.80 x 10 9 N/m 2 ) intrinsic stress than those of nonchopped bismuth oxide thin films (5.77 - 6.74 x 10 9 N/m 2 ). Intrinsic stress was found to increase due to air ageing. The effect of air ageing on the vapour chopped films was found low. The vapour chopped films showed higher packing density. Higher the packing density, lower the film will age. The process of chopping vapour flow creates films with less inhomogenety i.e. a low concentration of flaws and non-planar defects which results in lower intrinsic stress

  14. Multiple capture investigated by coincident electron spectroscopy in X7++Ar, at 70 keV

    International Nuclear Information System (INIS)

    Moretto-Capelle, P.; Bordenave-Montesquieu, D.; Bordenave-Montesquieu, A.

    1999-01-01

    The multiple electron capture in N 7+ + Ar and F 7+ (1s 2 ) + Ar systems is investigated at 70 keV with a new electron-recoil ion charge coincidence experiment. The whole electron energy range has been studied. Up to six electrons are found to be captured into autoionizing states. The recoil ion charge distribution associated with the emission of electrons is similar for both systems and found to be in good agreement with the prediction of Niehaus's model roughly adapted to take into account autoionizing cascades. New findings for the coincident double and triple captures are briefly discussed. A capture of an inner L-shell electron of Ar into the K-shell of the projectile is also observed in N 7+ + Ar collisions. (orig.)

  15. Heliospheric Neutral Atom Spectra Between 0.01 and 6 keV fom IBEX

    Science.gov (United States)

    Fuselier, S. A.; Allegrini, F.; Bzowski, M.; Funsten, H. O.; Ghielmetti, A. G.; Gloeckler, G.; Heirtzler, D.; Janzen, P.; Kubiak, M.; Kucharek, H.; hide

    2012-01-01

    Since 2008 December, the Interstellar Boundary Explorer (IBEX) has been making detailed observations of neutrals from the boundaries of the heliosphere using two neutral atom cameras with overlapping energy ranges. The unexpected, yet defining feature discovered by IBEX is a Ribbon that extends over the energy range from about 0.2 to 6 keV. This Ribbon is superposed on a more uniform, globally distributed heliospheric neutral population. With some important exceptions, the focus of early IBEX studies has been on neutral atoms with energies greater than approx. 0.5 keV. With nearly three years of science observations, enough low-energy neutral atom measurements have been accumulated to extend IBEX observations to energies less than approx. 0.5 keV. Using the energy overlap of the sensors to identify and remove backgrounds, energy spectra over the entire IBEX energy range are produced. However, contributions by interstellar neutrals to the energy spectrum below 0.2 keV may not be completely removed. Compared with spectra at higher energies, neutral atom spectra at lower energies do not vary much from location to location in the sky, including in the direction of the IBEX Ribbon. Neutral fluxes are used to show that low energy ions contribute approximately the same thermal pressure as higher energy ions in the heliosheath. However, contributions to the dynamic pressure are very high unless there is, for example, turbulence in the heliosheath with fluctuations of the order of 50-100 km/s.

  16. Copper-65-absorption by men fed intrinsically and extrinsically labeled whole wheat bread

    International Nuclear Information System (INIS)

    Johnson, P.E.; Lykken, G.I.

    1988-01-01

    Six men were fed a diet composed of conventional foods with all bread as whole wheat bread. Intrinsically labeled 65 Cu bread (containing 6.5 ppm Cu and 48 atom % 65 Cu) was substituted for unlabeled bread for 3 days, and stools were collected for 24 days. Extrinsically labeled bread was then substituted for 3 days and another 24-day stool collection made. 65 Cu excretion was measured by mass spectrometry. Mean Cu intake was 1.10 mg of Cu/day. Average Cu balance was /minus/0.06 /+-/ 0.08 mg/day. Average absorption of the intrinsic copper was 72.2 /+-/ 9.3% and of extrinsic Cu 64.2 /+-/ 5.8%. The ratio of extrinsic to intrinsic absorption was 0.906 /+-/ 0.164. Absorption of intrinsic and extrinsic tracers did not differ significantly (p > 0.05) by a paired t-test, and the ratio (E/I) was not significantly different from 1. Use of extrinsic Cu tracers to assess Cu absorption is supported by these results

  17. Rhenium-188-Lipiodol therapy of liver cancer: Optimization of conjugate-view imaging of 188Re for patient-specific dosimetry

    International Nuclear Information System (INIS)

    Chaudakshetrin, P.; Osorio, M.; Padhy, A.K.; Divgi, C.; Zanzonico, P.

    2004-01-01

    Full text: Intrahepatic artery Lipiodol labeled with generator-produced, β-emitting 188Re (17 hr; Eβ=0.53-0.70 MeV; Range=4 mm) localizes in and may effectively treat inoperable liver tumors. Although 188Re emits an imageable 155-keV γ ray (15%), its 478- and 633-keV β rays (2.3%) complicate imaging. Our objective was to optimize 188Re image quality and conjugate-view accuracy for quantitative imaging-based patient-specific dosimetry for 188Re-Lipiodol. Using an ADAC dual-EpicO-circumflex-detector gamma camera, 188Re intrinsic and extrinsic (with LEGP, MEGP, and HEGP collimation) uniformities using either 99mTc intrinsic or 188Re extrinsic flood corrections were evaluated. 188Re conjugate view count rate vs. activity concentration linearity as a function of scattering/attenuating medium thickness was then evaluated with and without corrections for attenuation (a 188Re transmission image) and for scatter and septal penetration, subtracting a fraction of counts in a lower-energy (109-140 keV)- and a higher-energy (170-201 keV)-window image, respectively, from the 20% (140-171 keV) photopeak image. Our phantom consisted of 5 10-ml vials containing 25 to 400 μCi/ml of 188Re with 0 to 6 cm at different positions (∼5 cm apart) between the detectors (60 cm apart) and with a 0- to 6-cm thickness of non-radioactive water between the vials and each detector. With a 99mTc intrinsic correction, 188Re intrinsic uniformity was excellent ( 10% and 'tubey'), and was poorer the lower the energy rating of the collimation. Uniformity with HEGP collimation and an extrinsic 188Re correction was acceptable ( 0.95) and the slope (cps/pixel/μCi/ml) was constant +25% (vs +10% for 99mTc) for 0- to 6-cm thicknesses of water. Regardless of the fraction of counts subtracted, neither scatter nor septal-penetration correction improved the slope constancy. Conclusion: Downscatter/septal penetration of the 478- and 633-keV 188Re γ-rays complicates imaging of its 155-keV γ-ray. Using HEGP

  18. Calibration of thin-film dosimeters irradiated with 80-120 kev electrons

    DEFF Research Database (Denmark)

    Helt-Hansen, J.; Miller, A.; McEwen, M.

    2004-01-01

    A method for calibration of thin-film dosimeters irradiated with 80-120keV electrons has been developed. The method is based on measurement of dose with a totally absorbing graphite calorimeter, and conversion of dose in the graphite calorimeter to dose in the film dosimeter by Monte Carlo calcul......V electron irradiation. The two calibrations were found to be equal within the estimated uncertainties of +/-10% at 1 s.d. (C) 2004 Elsevier Ltd. All rights reserved....

  19. Echo 2: observations at Fort Churchill of a 4-keV peak in low-level electron precipitation

    International Nuclear Information System (INIS)

    Arnoldy, R.L.; Hendrickson, R.A.; Winckler, J.R.

    1975-01-01

    The Echo 2 rocket flight launched from Fort Churchill, Manitoba, offered the opportunity to observe high-latitude low-level electron precipitation during quiet magnetic conditions. Although no visual aurora was evident at the time of the flight, an auroral spectrum sharply peaked at a few keV was observed to have intensities from 1 to 2 orders of magnitude lower than peaked spectra typically assoicated with bright auroral forms. There is a growing body of evidence that relates peaked electron spectra to discrete aurora. The Echo 2 observations show that whatever the mechanism for peaking the electron spectrum in and above discrete forms, it operates over a range of precipitation intensities covering nearly 3 orders of magnitude down to subvisual or near subvisual events

  20. Intrinsic and extrinsic motivation for smoking cessation.

    Science.gov (United States)

    Curry, S; Wagner, E H; Grothaus, L C

    1990-06-01

    An intrinsic-extrinsic model of motivation for smoking cessation was evaluated with 2 samples (ns = 1.217 and 151) of smokers who requested self-help materials for smoking cessation. Exploratory and confirmatory principal components analysis on a 36-item Reasons for Quitting (RFQ) scale supported the intrinsic-extrinsic motivation distinction. A 4-factor model, with 2 intrinsic dimensions (concerns about health and desire for self-control) and 2 extrinsic dimensions (immediate reinforcement and social influence), was defined by 20 of the 36 RFQ items. The 20-item measure demonstrated moderate to high levels of internal consistency and convergent and discriminant validity. Logistic regression analyses indicated that smokers with higher levels of intrinsic relative to extrinsic motivation were more likely to achieve abstinence from smoking.

  1. A 2-100 keV, UHV ion impact spectrometer for ion-solid interaction studies

    International Nuclear Information System (INIS)

    Berg, J.A. Van den; Armour, D.G.; Verheij, L.K.

    1978-01-01

    A 2 to 100 keV ion accelerator has been constructed as part of an ion impact spectrometer in which a number of analytical techniques have been combined to allow a comprehensive study of the interaction of low- and medium-energy ions with solids to be carried out under carefully controlled conditions. The overall requirements of the ion beam system in terms of ion species, beam purity, uniformity, energy spread and intensity were dictated by the interest in carrying out low-energy ion scattering, Rutherford back-scattering and thermal desorption experiments. The accelerator design utilises the principle of low-energy extraction and mass analysis, and post-acceleration up to the required high energy. The ions are produced in a duoplasmatron ion source and a parallel beam is obtained after mass selection, utilising a quadrupole triplet lens in conjunction with a 60 0 stigmatic focusing magnetic analyser. Proton and rare gas ion beams of 1 to 100 nA are routinely obtained on target. The 54 cm diameter, UHV target chamber is pumped by a 270 1 s -1 turbo-molecular pump in conjunction with an in-line titanium sublimator, and typical base pressures of 1 to 4 x 10 -11 Torr are achieved. The target is supported in a precision, three-axis goniometer and the detection system, at present comprising a 90 mm mean diameter hemispherical energy analyser and channel electron multiplier, is mounted on a two-axis manipulator. Preliminary measurements using the system have employed the low-energy ion scattering technique to study the oxidation of a Ni(110) surface. (author)

  2. Electron response of some low-Z scintillators in wide energy range

    International Nuclear Information System (INIS)

    Swiderski, L; Marcinkowski, R; Moszynski, M; Czarnacki, W; Szawlowski, M; Szczesniak, T; Pausch, G; Plettner, C; Roemer, K

    2012-01-01

    Light yield nonproportionality and the intrinsic resolution of some low atomic number scintillators were studied by means of the Wide Angle Compton Coincidence (WACC) technique. The plastic and liquid scintillator response to Compton electrons was measured in the energy range of 10 keV up to 4 MeV, whereas a CaF 2 :Eu sample was scanned from 3 keV up to 1 MeV. The nonproportionality of the CaF 2 :Eu light yield has characteristics typical for inorganic scintillators of the multivalent halides group, whereas tested organic scintillators show steeply increasing nonproportionality without saturation point. This is in contrast to the behavior of all known inorganic scintillators having their nonproportionality curves at saturation above energies between tens and several hundred keV.

  3. Electron response of some low-Z scintillators in wide energy range

    Science.gov (United States)

    Swiderski, L.; Marcinkowski, R.; Moszynski, M.; Czarnacki, W.; Szawlowski, M.; Szczesniak, T.; Pausch, G.; Plettner, C.; Roemer, K.

    2012-06-01

    Light yield nonproportionality and the intrinsic resolution of some low atomic number scintillators were studied by means of the Wide Angle Compton Coincidence (WACC) technique. The plastic and liquid scintillator response to Compton electrons was measured in the energy range of 10 keV up to 4 MeV, whereas a CaF2:Eu sample was scanned from 3 keV up to 1 MeV. The nonproportionality of the CaF2:Eu light yield has characteristics typical for inorganic scintillators of the multivalent halides group, whereas tested organic scintillators show steeply increasing nonproportionality without saturation point. This is in contrast to the behavior of all known inorganic scintillators having their nonproportionality curves at saturation above energies between tens and several hundred keV.

  4. Detailed tabulation of atomic form factors, photoelectric absorption and scattering cross section, and mass attenuation coefficients in the vicinity of absorption edges in the soft X-ray (Z=30-36, Z=60-89, E=0.1 keV-10 keV), addressing convergence issues of earlier work

    International Nuclear Information System (INIS)

    Chantler, C.T.

    2000-01-01

    Reliable knowledge of the complex x-ray form factor [Re(f ) ] and the photoelectric attenuation coefficient (σ PE ) is required for crystallography, medical diagnosis, radiation safety, and XAFS studies. Discrepancies between currently used theoretical approaches of 200% exist for numerous elements from 1 to 3 keV x-ray energies. The key discrepancies are due to the smoothing of edge structure, the use of nonrelativistic wave functions, and the lack of appropriate convergence of wave functions. This paper addresses these key discrepancies and derives new theoretical results of substantially higher accuracy in near-edge soft x-ray regions. The high-energy limitations of the current approach are also illustrated. The energy range covered is 0.1 to 10 keV. The associated figures and tabulation demonstrate the current comparison with alternate theory and with available experimental data. In general, experimental data are not sufficiently accurate to establish the errors and inadequacies of theory at this level. However, the best experimental data and the observed experimental structure as a function of energy are strong indicators of the validity of the current approach. New developments in experimental measurement hold great promise in making critical comparisons with theory in the near future

  5. A 60 keV implanter for metals

    International Nuclear Information System (INIS)

    Leutenecker, R.; Ryssel, H.; Zeller, K.-H.; Spoehrle, H.P.

    1985-01-01

    The design and preliminary performance data of a 60 keV high current implanter for the implantation of non-separated ion beams into metals are described. The target chamber accepts samples up to 70 cm in diameter and is equipped with holders to implant ball bearings, axles and other components which have to be rotated during implantation. Samples are mounted on a rugged table which can move up to 35 kg for +-35 cm in the x and y directions. The implanter, including the vacuum system, is completely computer controlled. The ion source is equipped with an oven having a maximum temperature of 1200 0 C and can deliver ion beams of nitrogen as well as different metal ions such as tin and silver with currents up to 10 mA. (Auth.)

  6. Dose response of thin-film dosimeters irradiated with 80-120 keV electrons

    DEFF Research Database (Denmark)

    Helt-Hansen, J.; Miller, A.; Sharpe, P.

    2005-01-01

    Thin-film dosimeters (Riso B3 and alanine films) were irradiated at 10 MeV and 80-120 keV electron accelerators, and it has been shown that the radiation response of the dosimeter materials (the radiation chemical yields) are constant at these irradiation energies. However, dose gradients within ...... are present within the dosimeter. (C) 2005 Elsevier Ltd. All rights reserved....

  7. Seeded quantum FEL at 478 keV

    Energy Technology Data Exchange (ETDEWEB)

    Guenther, Marc [Max-Planck-Institut fuer Quantenoptik, Garching (Germany); Thirolf, Peter; Seggebrock, Thorben [Ludwig-Maximilians-Universitaet Muenchen, Garching (Germany); Habs, Dietrich [Max-Planck-Institut fuer Quantenoptik, Garching (Germany); Ludwig-Maximilians-Universitaet Muenchen, Garching (Germany)

    2012-07-01

    We present for the first time a concept for a seeded {gamma} quantum Free Electron Laser (QFEL) at 478 keV (transition in {sup 7}Li). To produce a highly intense and coherent {gamma} beam, we intend to use a seeded FEL scheme. Important for the production of a highly brilliant and coherent {gamma} beam are novel refractive {gamma} lenses for focusing and an efficient monochromator, allowing to generate a very intense and coherent seed beam. To realize such a coherent {gamma} beam at 478 keV (1/38 A), it is suitable to use a quantum FEL design based on a new ''asymmetric'' laser-electron Compton back scattering scheme as pursued for the MeGaRay and ELI-NP facilities. Here the pulse length of the laser is much longer than the electron bunch length, equivalent to a {gamma}-FEL with laser wiggler. The coherence of a seeded QFEL can open up totally new areas of fundamental physics and applications. Especially, 478 keV can be attractive for ''green energy'' and life-science research, such as the detection of Li deposition in the brain for manic-depressive psychosis treatment with high spatial resolution or isotope-specific nuclear waste management and treatment.

  8. Variable Gap Undulator for 1.5-48 Kev Free Electron Laser at Linac Coherent Light Source

    International Nuclear Information System (INIS)

    2011-01-01

    We study the feasibility of generating femtosecond duration Free-Electron Laser with a variable photon energy from 1.5 to 48 keV, using an electron bunch with the same characteristics of the LINAC Coherent Light Source (LCLS) bunch, and a planar undulator with additional focusing. We assume that the electron bunch energy can be changed, and the undulator has a variable gap, allowing a variable undulator parameter. It is assumed to be operated in an ultra-low charge and ultra-short pulse regime. We study the feasibility of a tunable, short pulse, X-ray FEL with photon energy from 1.5 to 48 keV, using an electron beam like the one in the LCLS and a 2:5 cm period, variable gap, planar undulator. The beam energy changes from 4.6 to 13.8 GeV, the electorn charge is kept at 10 pC, and the undulator parameter varies from 1 to 3. The undulator length needed to saturate the 48 keV FEL is about 55 m, with a peak power around 5 GW. At longer wavelength the saturation length is as short as 15 m, and the peak power around 20 GW. The results from the analytical models and the GENESIS simulations show that the system is feasible. The large wavelength range, full tunability and short, few femtosecond pulses, together with the large peak power, would provide a powerful research tool.

  9. NEW OBSERVATIONS OF THE SOLAR 0.5–5 KEV SOFT X-RAY SPECTRUM

    Energy Technology Data Exchange (ETDEWEB)

    Caspi, Amir; Woods, Thomas N. [Laboratory for Atmospheric and Space Physics, University of Colorado, Boulder, CO 80303 (United States); Warren, Harry P. [Space Science Division, Naval Research Laboratory, Washington, DC 20375 (United States)

    2015-03-20

    The solar corona is orders of magnitude hotter than the underlying photosphere, but how the corona attains such high temperatures is still not understood. Soft X-ray (SXR) emission provides important diagnostics for thermal processes in the high-temperature corona, and is also an important driver of ionospheric dynamics at Earth. There is a crucial observational gap between ∼0.2 and ∼4 keV, outside the ranges of existing spectrometers. We present observations from a new SXR spectrometer, the Amptek X123-SDD, which measured the spatially integrated solar spectral irradiance from ∼0.5 to ∼5 keV, with ∼0.15 keV FWHM resolution, during sounding rocket flights on 2012 June 23 and 2013 October 21. These measurements show that the highly variable SXR emission is orders of magnitude greater than that during the deep minimum of 2009, even with only weak activity. The observed spectra show significant high-temperature (5–10 MK) emission and are well fit by simple power-law temperature distributions with indices of ∼6, close to the predictions of nanoflare models of coronal heating. Observations during the more active 2013 flight indicate an enrichment of low first-ionization potential elements of only ∼1.6, below the usually observed value of ∼4, suggesting that abundance variations may be related to coronal heating processes. The XUV Photometer System Level 4 data product, a spectral irradiance model derived from integrated broadband measurements, significantly overestimates the spectra from both flights, suggesting a need for revision of its non-flare reference spectra, with important implications for studies of Earth ionospheric dynamics driven by solar SXRs.

  10. Intrinsic-extrinsic factors in sport motivation.

    Science.gov (United States)

    Pedersen, Darhl M

    2002-10-01

    Participants were 83 students (36 men and 47 women). 10 intrinsic-extrinsic factors involved in sport motivation were obtained. The factors were generated from items obtained from the participants rather than items from the experimenter. This was done to avoid the possible influence of preconceptions on the part of the experimenter regarding what the final dimensions may be. Obtained motivational factors were Social Reinforcement, Fringe Benefits, Fame and Fortune, External Forces, Proving Oneself, Social Benefits, Mental Enrichment, Expression of Self, Sense of Accomplishment, and Self-enhancement. Each factor was referred to an intrinsic-extrinsic dimension to describe its relative position on that dimension. The order of the factors as listed indicates increasing intrinsic motivation. i.e., the first four factors were rated in the extrinsic range, whereas the remaining six were rated to be in the intrinsic range. Next, the participants rated the extent to which each of the various factors was involved in their decision to participate in sport activities. The pattern of use of the motivational factors was the same for both sexes except that men indicated greater use of the Fringe Benefits factor. Overall, the more intrinsic a sport motivation factor was rated, the more likely it was to be rated as a factor in actual sport participation.

  11. Study of microstructure and magnetic properties of L10 FePt/SiO2 thin films

    Directory of Open Access Journals (Sweden)

    Giannopoulos G.

    2014-07-01

    Full Text Available Achieving magnetic recording densities in excess of 1Tbit/in2 requires not only perpendicular media with anisotropies larger than 7 MJ/m3, making FePt alloys an ideal choice, but also a narrow distribution below 10 nm for a reduced S/N ratio. Such grain size reduction and shape control are crucial parameters for high density magnetic recording, along with high thermal stability. Previous work has shown that the L10 FePt grain size can be controlled by alloying FePt with materials such as C, Ag, and insulators such as AlOx, MgO. Au and Al2O3 also act to segregate and magnetically decouple the FePt grains. Better results were obtained with C with respect to the uniformity of grains and SiO2 with respect to the shape. We present our results on co-sputtering FePt with C or SiO2 (up to 30 vol % on MgO (001 single crystal substrates at 350 and 500 oC. With C or SiO2 addition we achieved grain size reduction, shape control and isolated structure formation, producing continuous films with high uniformity and a narrow grain size distribution. These additions thus allow us to simultaneously control the coercivity and the S/N ratio. We also will report structural and microstructural properties.

  12. Gold standard capture cross section from 100 keV to 15 MeV

    International Nuclear Information System (INIS)

    Ryves, T.B.

    1982-01-01

    The capture cross section of gold is now generally accepted as the principal reference standard, and therefore in this review only gold is considered. Recent measurements of the gold capture cross section in the unresolved region are discussed and compared with the ENDF/B-V evaluation. It is concluded that in the energy interval 100 to 2000 keV the present uncertainty in the evaluation is +-8%, in the interval 2 to 3.5 MeV the uncertainty is +-4%, in ther interval 3.5 to 14 MeV more measurements are needed before a realistic error can be assigned, and from 14 to 15 MeV the uncertainty is +-10%. Several recommendations for future work have been made

  13. Research on relation of HRS/IRR and anti-oxidases in E.coli implanted by 30 keV N+

    International Nuclear Information System (INIS)

    Yang Tianyou; Wang Tiegu; Tian Jing; Chang Jingling; Qing Guangyong

    2010-01-01

    The inducement of hyperradiosensitivity/increased radioresistance (HRS/IRR) and activities of anti-oxidases in Escherichia coli implanted by 30 keV N + and relationship between them were investigated. The results showed the change trend of the survival rate and the activity of superoxide dismutase (SOD) and Catalas(CAT) of E. coli K12 was consistent. The activity of SOD and CAT of E.coli were lower, less than 10 and 8 U/mg, when the HRS was induced at 0 - 5 x 10 14 N + /cm 2 doses. And the activity of SOD and CAT of E. coli increased and reached highest rate, were 58 and 26 U/mg respectively, when the IRR was induced at 5 x 10 14 - 10 x 10 14 N + /cm 2 doses. It could be concluded that the change of SOD and CAT activity was related with the HRS/IRR. (authors)

  14. Plasma coenzyme Q10 levels in type 2 diabetic patients with retinopathy

    Science.gov (United States)

    Ates, Orhan; Bilen, Habip; Keles, Sadullah; Alp, H. Hakan; Keleş, Mevlüt Sait; Yıldırım, Kenan; Öndaş, Osman; Pınar, L. Can; Civelekler, Mustafa; Baykal, Orhan

    2013-01-01

    AIM To determine the relationship between proliferative diabetic retinopathy (PDRP) and plasma coenzyme Q10(CoQ10) concentration. METHODS Patients with type 2 diabetes and PDRP were determined to be the case group (n=50). The control group was consist of healthy individuals (n=50). Plasma CoQ10 and malondialdehyde (MDA) levels were measured in both groups. RESULTS Ubiquinone-10 (Coenzyme Q10) levels in PDRP and control subjects are 3.81±1.19µmol/L and 1.91±0.62µmol/L, respectively. Plasma MDA levels in PDRP and control subjects were 8.16±2µmol/L and 3.44±2.08µmol/L, respectively. Ratio of Ubiquinol-10/ubiquinone-10 in PDRP and control subjects were 0.26±0.16 and 1.41±0.68, respectively. CONCLUSION The ratio of ubiquinol-10/ubiquinone-10 is found lower in patients with PDRP. High levels of plasma ubiquinol-10/ubiquinone-10 ratio indicate the protective effect on diabetic retinopathy. PMID:24195048

  15. Plasma coenzyme Q10 levels in type 2 diabetic patients with retinopathy

    Directory of Open Access Journals (Sweden)

    Orhan Ates

    2013-10-01

    Full Text Available AIM: To determine the relationship between proliferative diabetic retinopathy (PDRP and plasma coenzyme Q10(CoQ10 concentration.METHODS: Patients with type 2 diabetes and PDRP were determined to be the case group (n=50. The control group was consist of healthy individuals (n=50. Plasma CoQ10 and malondialdehyde (MDA levels were measured in both groups.RESULTS: Ubiquinone-10 (Coenzyme Q10 levels in PDRP and control subjects are 3.81±1.19µmol/L and 1.91±0.62µmol/L, respectively. Plasma MDA levels in PDRP and control subjects were 8.16±2µmol/L and 3.44±2.08µmol/L, respectively. Ratio of Ubiquinol-10/ubiquinone-10 in PDRP and control subjects were 0.26±0.16 and 1.41±0.68, respectively.CONCLUSION:The ratio of ubiquinol-10/ubiquinone-10 is found lower in patients with PDRP. High levels of plasma ubiquinol-10/ubiquinone-10 ratio indicate the protective effect on diabetic retinopathy.

  16. Intrinsic and extrinsic motivation as predictors of work effort: The moderating role of achievement goals

    OpenAIRE

    Dysvik, Anders; Kuvaas, Bård

    2013-01-01

    This is the accepted, refereed and final manuscript to the article This research explored the roles of intrinsic and extrinsic motivation and the 2 x 2 model of achievement goals as predictors of increased work effort. A cross-lagged field study was conducted among 1,441 employees from three large Norwegian service organizations across a 10-month time span. The results showed that the relationship between intrinsic motivation and increased work effort was more positive for employees with h...

  17. A L2HGDH initiator methionine codon mutation in a Yorkshire terrier with L-2-hydroxyglutaric aciduria

    Directory of Open Access Journals (Sweden)

    Farias Fabiana HG

    2012-07-01

    Full Text Available Abstract Background L-2-hydroxyglutaric aciduria is a metabolic repair deficiency characterized by elevated levels of L-2-hydroxyglutaric acid in urine, blood and cerebrospinal fluid. Neurological signs associated with the disease in humans and dogs include seizures, ataxia and dementia. Case presentation Here we describe an 8 month old Yorkshire terrier that presented with episodes of hyperactivity and aggressive behavior. Between episodes, the dog’s behavior and neurologic examinations were normal. A T2 weighted MRI of the brain showed diffuse grey matter hyperintensity and a urine metabolite screen showed elevated 2-hydroxyglutaric acid. We sequenced all 10 exons and intron-exon borders of L2HGDH from the affected dog and identified a homozygous A to G transition in the initiator methionine codon. The first inframe methionine is at p.M183 which is past the mitochondrial targeting domain of the protein. Initiation of translation at p.M183 would encode an N-terminal truncated protein unlikely to be functional. Conclusions We have identified a mutation in the initiation codon of L2HGDH that is likely to result in a non-functional gene. The Yorkshire terrier could serve as an animal model to understand the pathogenesis of L-2-hydroxyglutaric aciduria and to evaluate potential therapies.

  18. Accretion Properties of a Sample of Hard X-Ray (<60 keV) Selected Seyfert 1 Galaxies

    Science.gov (United States)

    Wang, J.; Mao, Y. F.; Wei, J. Y.

    2009-02-01

    We examine the accretion properties in a sample of 42 hard (3-60 keV) X-ray selected nearby broad-line active galactic nuclei (AGNs). The energy range in the sample is harder than that usually used in similar previous studies. These AGNs are mainly complied from the RXTE All Sky Survey, and complemented by the released INTEGRAL AGN catalog. The black hole masses, bolometric luminosities of AGN, and Eddington ratios are derived from their optical spectra in terms of the broad Hβ emission line. The tight correlation between the hard X-ray (3-20 keV) and bolometric/line luminosity is well identified in our sample. Also identified is a strong inverse Baldwin relationship of the Hβ emission line. In addition, all of these hard X-ray AGNs are biased toward luminous objects with a high Eddington ratio (mostly between 0.01 and 0.1) and a low column density (Simbol-X, and NeXT. Finally, the correlation between RFe (= optical Fe II/Hβ) and disk temperature as assessed by T vprop (L/L Edd)M -1 BH leads us to suggest that the strength of the Fe II emission is mainly determined by the shape of the ionizing spectrum.

  19. A deep NuSTAR observation of M51: Investigating its Compton-thick nucleus, LINER companion and ULXs above 10 keV

    Science.gov (United States)

    Brightman, Murray; Annuar, Ady; Alexander, David M.; Earnshaw, Hannah; Gandhi, Poshak; Hornschemeier, Ann E.; Lehmer, Bret; Ptak, Andrew; Rangelov, Blagoy; Roberts, Tim P.; Stern, Daniel; Zezas, Andreas

    2017-08-01

    We present the results from a deep 200ks observation of M51 with NuSTAR. This observation was taken simultaneously with Chandra to provide soft-X-ray-coverage as well as to resolve the different point sources. We detect the Compton-thick nucleus of M51a, the LINER nucleus of M51b and several ultraluminous X-ray sources located in the galaxies above 10 keV. From X-ray torus modeling, we find that the covering factor of the torus in the nucleus of M51a is ~40% and supports a decline in the obscured fration at low X-ray luminosities. We find that the X-ray spectrum of the intermediate mass black hole candidate, ULX-7, is consistent with a power-law up to high energies, supporting its IMBH status. We further resolve the nucleus of M51b into two X-ray sources with Chandra, and measure its X-ray luminosity.

  20. Study on the keV neutron capture reaction in 56Fe and 57Fe

    Science.gov (United States)

    Wang, Taofeng; Lee, Manwoo; Kim, Guinyun; Ro, Tae-Ik; Kang, Yeong-Rok; Igashira, Masayuki; Katabuchi, Tatsuya

    2014-03-01

    The neutron capture cross-sections and the radiative capture gamma-ray spectra from the broad resonances of 56Fe and 57Fe in the neutron energy range from 10 to 90keV and 550keV have been measured with an anti-Compton NaI(Tl) detector. Pulsed keV neutrons were produced from the 7Li 7Be reaction by bombarding the lithium target with the 1.5ns bunched proton beam from the 3MV Pelletron accelerator. The incident neutron spectrum on a capture sample was measured by means of a time-of-flight (TOF) method with a 6Li -glass detector. The number of weighted capture counts of the iron or gold sample was obtained by applying a pulse height weighting technique to the corresponding capture gamma-ray pulse height spectrum. The neutron capture gamma-ray spectra were obtained by unfolding the observed capture gamma-ray pulse height spectra. To achieve further understanding on the mechanism of neutron radiative capture reaction and study on physics models, theoretical calculations of the -ray spectra for 56Fe and 57Fe with the POD program have been performed by applying the Hauser-Feshbach statistical model. The dominant ingredients to perform the statistical calculation were the Optical Model Potential (OMP), the level densities described by the Mengoni-Nakajima approach, and the -ray transmission coefficients described by -ray strength functions. The comparison of the theoretical calculations, performed only for the 550keV point, show a good agreement with the present experimental results.

  1. Cummins L10G in Kenworth truck 'viable today'

    International Nuclear Information System (INIS)

    Anon.

    1996-01-01

    As the culmination of five years of developmental work by Cummins Engines, BC Research Inc., and BC Gas Utility Ltd., a T800 Kenworth truck was outfitted with a new Cummins L10G natural gas engine, and two lightweight fully -wrapped Dynetek cylinders; it was pronounced to be 'a viable clean truck today'. The L10G spark-ignited engine operates at a relatively high peak efficiency of 37 per cent and is commercially available to meet the current California Air Resources Board heavy duty vehicle emission standards without the use of a catalytic converter. The L10G engine produces no particulate emissions, a very significant advantage, in view of the fact that particulate emissions have been identified as major contributors to respiratory ailments

  2. Reducing the effects of metal artefact using high keV monoenergetic reconstruction of dual energy CT (DECT) in hip replacements

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Mark [Norfolk and Norwich University Hospital, Norwich (United Kingdom); Norwich Radiology Academy, Norwich (United Kingdom); Reid, Karen [Norfolk and Norwich University Hospital, Norwich (United Kingdom); Toms, Andoni P. [Norfolk and Norwich University Hospital and University of East Anglia, Norwich (United Kingdom)

    2013-02-15

    The aim of this study was to determine whether high keV monoenergetic reconstruction of dual energy computed tomography (DECT) could be used to overcome the effects of beam hardening artefact that arise from preferential deflection of low energy photons. Two phantoms were used: a Charnley total hip replacement set in gelatine and a Catphan 500. DECT datasets were acquired at 100, 200 and 400 mA (Siemens Definition Flash, 100 and 140 kVp) and reconstructed using a standard combined algorithm (1:1) and then as monoenergetic reconstructions at 10 keV intervals from 40 to 190 keV. Semi-automated segmentation with threshold inpainting was used to obtain the attenuation values and standard deviation (SD) of the streak artefact. High contrast line pair resolution and background noise were assessed using the Catphan 500. Streak artefact is progressively reduced with increasing keV monoenergetic reconstructions. Reconstruction of a 400 mA acquisition at 150 keV results in reduction in the volume of streak artefact from 65 cm{sup 3} to 17 cm{sup 3} (74 %). There was a decrease in the contrast to noise ratio (CNR) at higher tube voltages, with the peak CNR seen at 70-80 keV. High contrast spatial resolution was maintained at high keV values. Monoenergetic reconstruction of dual energy CT at increasing theoretical kilovoltages reduces the streak artefact produced by beam hardening from orthopaedic prostheses, accompanied by a modest increase in heterogeneity of background image attenuation, and decrease in contrast to noise ratio, but no deterioration in high contrast line pair resolution. (orig.)

  3. Thermal desorption spectroscopy of boron/carbon films after keV deuterium irradiation

    International Nuclear Information System (INIS)

    Yamaki, T.; Gotoh, Y.; Ando, T.; Jimbou, R.; Ogiwara, N.; Saidoh, M.

    1994-01-01

    Thermal desorption spectroscopy (TDS) of D 2 and CD 4 was done on boron/carbon films (B/(B+C)=0-74%), after 3 keV D 3 + irradiation to 4.5x10 17 D/cm 2 at 473 K. The D 2 desorption peaks were observed at 1050, 850 and 650 K. For a sputter B/C film (0%), only the 1050 K peak was observed. With increasing boron concentration to 3%, a sharp peak appeared at 850 K, the intensity of which was found to increase with increasing boron concentration to 23%, and then to decrease at 74%. The 650 K shoulder, which was observed for high boron concentration specimens, was speculated to be deuterium trapped by boron atoms in the boron clusters. The relative amount of CD 4 desorption was found to decrease with increasing boron concentration, which was attributed to the decrease in the trapped deuterium concentration in the implantation layer at temperatures at which CD 4 desorption proceeds. ((orig.))

  4. Radiation damage studies on STAR250 CMOS sensor at 300 keV for electron microscopy

    International Nuclear Information System (INIS)

    Faruqi, A.R.; Henderson, R.; Holmes, J.

    2006-01-01

    There is a pressing need for better electronic detectors to replace film for recording high-resolution images using electron cryomicroscopy. Our previous work has shown that direct electron detection in CMOS sensors is promising in terms of resolution and efficiency at 120 keV [A.R. Faruqi, R. Henderson, M. Prydderch, R. Turchetta, P. Allport, A. Evans, Nucl. Instr. and Meth. 546 (2005) 170], but in addition, the detectors must not be damaged by the electron irradiation. We now present new measurements on the radiation tolerance of a 25 μm pitch CMOS active-pixel sensor, the STAR250, which was designed by FillFactory using radiation-hard technology for space applications. Our tests on the STAR250 aimed to establish the imaging performance at 300 keV following irradiation. The residual contrast, measured on shadow images of a 300 mesh grid, was >80% after corrections for increased dark current, following irradiation with up to 5x10 7 electrons/pixel (equivalent to 80,000 electron/μm 2 ). A CMOS sensor with this degree of radiation tolerance would survive a year of normal usage for low-dose electron cryomicroscopy, which is a very useful advance

  5. L2 learner age from a contextualised perspective

    Directory of Open Access Journals (Sweden)

    Jelena Mihaljeviđ Djigunoviđ

    2014-01-01

    Full Text Available In this qualitative study the author focuses on age effects on young learners’ L2 development by comparing the L2 learning processes of six young learners in an instructed setting: three who had started learning English as L2 at age 6/7 and three who had started at age 9/10. Both earlier and later young beginners were followed for three years (during their second, third and fourth year of learning English. The participants’ L2 development was measured through their oral output elicited by a two-part speaking task administered each year. Results of the analyses are interpreted taking into account each learners’ individual characteristics (learning ability, attitudes and motivation, self-concept and the characteristics of the context in which they were learning their L2 (attitudes of school staff and parents to early L2 learning, home support, in-class and out-of-class exposure to L2, socio-economic status. The findings show that earlier and later young beginners follow different trajectories in their L2 learning, which reflects different interactions which age enters into with the other variables.

  6. Iron-59 absorption from soy hulls: intrinsic vs extrinsic labeling

    International Nuclear Information System (INIS)

    Lykken, G.I.; Mahalko, J.R.; Nielsen, E.J.; Dintzis, F.R.

    1986-01-01

    As part of an evaluation of the validity of the extrinsic labeling technique for measuring iron absorption, absorption from soy hulls extrinsically labeled ( 59 Fe added to bread dough) was compared with that from soy hulls intrinsically labeled ( 59 Fe incorporated into the soy plant during growth). Century soybeans were grown in a greenhouse. After pods had formed and were filling, each plant was stem injected twice, at 3 day intervals, with 22 μCi 59 Fe as FeCl 2 in 25 μl of 0.5 M HCl solution. After the plants had senesced, the soybeans were harvested, dried, shelled and the hulls removed. Standard meals containing 3.5 mg Fe/meal and up to 0.06 μCi 59 Fe in a soy hull bun were fed on 2 consecutive days to free-living volunteers in a crossover design. Absorption of 59 Fe was greater from intrinsically labeled soy hulls than from extrinsically labeled soy hulls, 20 +/- 20% vs 15 +/- 11% (n=14, p > 0.05 by paired t-test). Apparent absorption ranged from 1.3% to 77% from intrinsically labeled soy hulls and .5% to 29% from extrinsically labeled soy hulls with the highest absorption occurring in persons with low serum ferritin (S.F. < 8 ng/ml). These findings provide additional evidence that the extrinsic labeling method is a valid measure of iron bioavailability to humans

  7. Giant thermally-enhanced electrostriction and polar surface phase in L a2M o2O9 oxygen ion conductors

    Science.gov (United States)

    Li, Qian; Lu, Teng; Schiemer, Jason; Laanait, Nouamane; Balke, Nina; Zhang, Zhan; Ren, Yang; Carpenter, Michael A.; Wen, Haidan; Li, Jiangyu; Kalinin, Sergei V.; Liu, Yun

    2018-04-01

    Ferroelectrics possess spontaneous electric polarization at macroscopic scales which nonetheless imposes strict limitations on the material classes. Recent discoveries of untraditional symmetry-breaking phenomena in reduced material dimensions have indicated feasibilities to extend polar properties to broader types of materials, potentially opening up the freedom for designing materials with hybrid functionalities. Here, we report the unusual electromechanical properties of L a2M o2O9 (LAMOX) oxygen ion conductors, systematically investigated at both bulk and surface length levels. We first observed giant electrostriction effects in L a2M o2O9 bulk ceramics that are thermally enhanced in concert with their low-energy oxygen-vacancy hopping dynamics. Moreover, while no clear bulk polarization was detected, the surface phases of LAMOX were found to be manifestly polar, likely originating from the coupling between the intrinsic structural flexibilities with strain gradients (i.e., flexoelectricity) and/or chemical heterogeneities present in the materials. These findings identify L a2M o2O9 as a promising electromechanical material system and suggest that the flexible structural and chemical configurations in ionically active materials could enable fundamentally different venues to accommodate electric polarization.

  8. On the 1285,0 keV; 55-184WW state structure

    International Nuclear Information System (INIS)

    Kupryashkin, V.T.; Muzalev, P.N.; Feoktistov, A.I.

    1977-01-01

    The structure of the 184 W (1285.0 keV; 5 - ) states is discussed. Decay of this level is shown schematically. The data on multiplicities and probabilities of the γ-transitions for the levels 1285.0 keV; 5 - of 184 W and 1621.4 keV; 5 - of 182 W are presented. The transition amplitude parameters are plotted for different probabilities B(E3;5 - → I + ). The relation between the collective transition amplitudes is established. Transition amplitude parameters and their collective and two-particle components, as well as impurity amplitudes of collective excitation wave functions and matrix elements are given

  9. Dense ion clouds of 0.1 − 2 keV ions inside the CPS-region observed by Astrid-2

    Directory of Open Access Journals (Sweden)

    O. Norberg

    Full Text Available Data from the Astrid-2 satellite taken between April and July 1999 show several examples of dense ion clouds in the 0.1–2 keV energy range inside the inner mag-netosphere, both in the northern and southern hemispheres. These inner magnetospheric ion clouds are found predomi-nantly in the early morning sector, suggesting that they could have originated from substorm-related ion injections on the night side. However, their location and density show no cor-relation with Kp, and their energy-latitude dispersion is not easily reproduced by a simple particle drift model. There-fore, these ion clouds are not necessarily caused by substorm-related ion injections. Alternative explanations for the ion clouds are the direct solar wind injections and up-welling ions from the other hemisphere. These explanations do not, however, account for all of the observations.Key words. Magnetospheric physics (energetic particles, trapped; magnetospheric configuration and dynamics; storm and substorms

  10. A position sensitive detector using a NaI(Tl)/photomultiplier tube combination for the energy range 200 keV to 10 MeV

    International Nuclear Information System (INIS)

    Court, A.J.; Dean, A.J.; Yearworth, M.; Younis, F.; Chiappetti, L.; Perotti, F.; Villa, G.; Ubertini, P.; La Padula, C.

    1988-01-01

    The performance of the position sensitive detector for the ZEBRA low energy gamma-ray imaging telescope is described. The detector consists of 9 position sensitive NaI(Tl) elements each 5.8x5.0x56.0 cm viewed at either end of the long axis by 2 in. photomultiplier tubes. The total active area is 2470 cm 2 with an average positional resolution of 2.1 cm and energy resolution of 15% FWHM at 661.6 keV. The method of flight calibration is described together with the provision within the on-board electronics to correct for sources of error in the calculation of event energy loss and position. The results presented are obtained from the calibration phase of the ZEBRA telescope project. (orig.)

  11. Sport ability beliefs, 2 x 2 achievement goals, and intrinsic motivation: the moderating role of perceived competence in sport and exercise.

    Science.gov (United States)

    Wang, C K John; Liu, Woon Chia; Lochbaum, Marc R; Stevenson, Sarah J

    2009-06-01

    We examined whether perceived competence moderated the relationships between implicit theories, 2 x 2 achievement goals, and intrinsic motivation for sports and physical activity. We placed 309 university students into high and moderate perceived competence groups. When perceived competence was high, entity beliefs did not predict the performance-avoidance goal; yet when perceived competence was moderately low, entity beliefs did predict this goal. The mastery-avoidance goal had no relationship with intrinsic motivation when perceived competence was high, but had a significant negative relationship when perceived competence was moderately low. Our findings highlight the importance of reexamining the role of perceived competence when studying implicit beliefs and the 2 x 2 achievement goals.

  12. The 2-79 keV X-ray spectrum of the circinus galaxy with NuSTAR, XMM-Newton, and Chandra: a fully compton-thick active galactic nucleus

    DEFF Research Database (Denmark)

    Arévalo, P.; Bauer, F. E.; Puccetti, S.

    2014-01-01

    The Circinus galaxy is one of the closest obscured active galactic nuclei (AGNs), making it an ideal target for detailed study. Combining archival Chandra and XMM-Newton data with new NuSTAR observations, we model the 2-79 keV spectrum to constrain the primary AGN continuum and to derive physical......-nuclear emission amounts to 18% of the nuclear flux in the Fe line region, but becomes comparable to the nuclear emission above 30 keV. The new analysis no longer supports a prominent transmitted AGN component in the observed band. We find that the nuclear spectrum is consistent with Compton scattering...

  13. NGC1448 and IC 3639: Two Concealed Black Holes Lurking in our Cosmic Backyard Unveiled by NuSTAR

    Science.gov (United States)

    Stern, Daniel; Boorman, Peter; Annuar, Ady; Gandhi, Poshak; Alexander, D. M.; Lansbury, George B.; Asmus, Daniel; Ballantyne, David R.; Bauer, Franz E.; Boggs, Steven E.; Brandt, W. Niel; Brightman, Murray; Christensen, Finn; Craig, William W.; Farrah, Duncan; Goulding, Andy D.; Hailey, Charles James; Harrison, Fiona; Hoenig, Sebastian; Koss, Michael; LaMassa, Stephanie M.; Masini, Alberto; Murray, Stephen S.; Ricci, Claudio; Risaliti, Guido; Rosario, David J.; Stanley, Flora; Zhang, William

    2017-01-01

    We present NuSTAR observations of two nearby Active Galactic Nuclei (AGN), NGC 1448 and IC 3639, located at distances of 12 Mpc and 54 Mpc, respectively. NuSTAR high-energy X-ray (> 10 keV) observations, combined with archival lower energy X-ray observations from Chandra and Suzaku, reveal both sources to contain heavily obscured, accreting super-massive black holes. NGC 1448 is one of the nearest luminous galaxies to the Milky Way, yet the AGN at its centre was only discovered in 2009. Using state-of-the-art models, we constrain the obscuring column density (NH) of gas concealing both AGN, finding them to be extreme, with NH values well into the Compton-thick (CT) regime with N(H) > 3e24 /cm2. NGC 1448 has an intrinsic X-ray luminosity of L(24 keV) ˜ 5e40 erg/s, making it one of the lowest luminosity CT AGN known. IC 3639, on the other hand, has one of the strongest iron fluorescence emission lines known. We also discuss multi-wavelength diagnostics at optical and mid-infrared energies as indirect indicators to penetrate through the obscuring veils and probe the intrinsic properties of the AGN. Through detailed studies such as we present here, NuSTAR is showing that there are still plenty of interesting discoveries awaiting to be made, even in the nearby Universe.

  14. Vibrational spectroscopic and theoretical study of 3,5-dimethyl-1-thiocarboxamide pyrazole (L) and the complexes Co2L2Cl4, Cu2L2Cl4 and Cu2L2Br2

    International Nuclear Information System (INIS)

    Nemcsok, Denes; Kovacs, Attila; Szecsenyi, Katalin Meszaros; Leovac, Vukadin M.

    2006-01-01

    In the present paper we report a joint experimental and theoretical study of 3,5-dimethyl-1-thiocarboxamide pyrazole (L) and its complexes Co 2 L 2 Cl 4 , Cu 2 L 2 Cl 4 and Cu 2 L 2 Br 2 . DFT computations were used to model the structural and bonding properties of the title compounds as well as to derive a reliable force field for the normal coordinate analysis of L. The computations indicated the importance of hydrogen bonding interactions in stabilising the global minimum structures on the potential energy surfaces. In contrast to the S-bridged binuclear Cu 2 L 2 Br 2 complex found in the crystal, our computations predicted the formation of (CuLBr) 2 dimers in the isolated state stabilized by very strong (53 kJ/mol) N-H...Br hydrogen bonding interactions. On the basis of FT-IR and FT-Raman experiments and the DFT-derived scaled quantum mechanical force field we carried out a complete normal coordinate analysis of L. The FT-IR spectra of the three complexes were interpreted using the present assignment of L, literature data and computed results

  15. Reduction of transient diffusion from 1 endash 5 keV Si+ ion implantation due to surface annihilation of interstitials

    International Nuclear Information System (INIS)

    Agarwal, A.; Gossmann, H.-.; Eaglesham, D.J.; Pelaz, L.; Jacobson, D.C.; Haynes, T.E.; Erokhin, Y.E.

    1997-01-01

    The reduction of transient enhanced diffusion (TED) with reduced implantation energy has been investigated and quantified. A fixed dose of 1x10 14 cm -2 Si + was implanted at energies ranging from 0.5 to 20 keV into boron doping superlattices and enhanced diffusion of the buried boron marker layers was measured for anneals at 810, 950, and 1050 degree C. A linearly decreasing dependence of diffusivity enhancement on decreasing Si + ion range is observed at all temperatures, extrapolating to ∼1 for 0 keV. This is consistent with our expectation that at zero implantation energy there would be no excess interstitials from the implantation and hence no TED. Monte Carlo modeling and continuum simulations are used to fit the experimental data. The results are consistent with a surface recombination length for interstitials of <10 nm. The data presented here demonstrate that in the range of annealing temperatures of interest for p-n junction formation, TED is reduced at smaller ion implantation energies and that this is due to increased interstitial annihilation at the surface. copyright 1997 American Institute of Physics

  16. Steady State Sputtering Yields and Surface Compositions of Depleted Uranium and Uranium Carbide bombarded by 30 keV Gallium or 16 keV Cesium Ions.

    Energy Technology Data Exchange (ETDEWEB)

    Siekhaus, W. J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Teslich, N. E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Weber, P. K. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2014-10-23

    Depleted uranium that included carbide inclusions was sputtered with 30-keV gallium ions or 16-kev cesium ions to depths much greater than the ions’ range, i.e. using steady-state sputtering. The recession of both the uranium’s and uranium carbide’s surfaces and the ion corresponding fluences were used to determine the steady-state target sputtering yields of both uranium and uranium carbide, i.e. 6.3 atoms of uranium and 2.4 units of uranium carbide eroded per gallium ion, and 9.9 uranium atoms and 3.65 units of uranium carbide eroded by cesium ions. The steady state surface composition resulting from the simultaneous gallium or cesium implantation and sputter-erosion of uranium and uranium carbide were calculated to be U₈₆Ga₁₄, (UC)₇₀Ga₃₀ and U₈₁Cs₉, (UC)₇₉Cs₂₁, respectively.

  17. Intrinsic Thermodynamics and Structures of 2,4- and 3,4-Substituted Fluorinated Benzenesulfonamides Binding to Carbonic Anhydrases.

    Science.gov (United States)

    Zubrienė, Asta; Smirnov, Alexey; Dudutienė, Virginija; Timm, David D; Matulienė, Jurgita; Michailovienė, Vilma; Zakšauskas, Audrius; Manakova, Elena; Gražulis, Saulius; Matulis, Daumantas

    2017-01-20

    The goal of rational drug design is to understand structure-thermodynamics correlations in order to predict the chemical structure of a drug that would exhibit excellent affinity and selectivity for a target protein. In this study we explored the contribution of added functionalities of benzenesulfonamide inhibitors to the intrinsic binding affinity, enthalpy, and entropy for recombinant human carbonic anhydrases (CA) CA I, CA II, CA VII, CA IX, CA XII, and CA XIII. The binding enthalpies of compounds possessing similar chemical structures and affinities were found to be very different, spanning a range from -90 to +10 kJ mol -1 , and are compensated by a similar opposing entropy contribution. The intrinsic parameters of binding were determined by subtracting the linked protonation reactions. The sulfonamide group pK a values of the compounds were measured spectrophotometrically, and the protonation enthalpies were measured by isothermal titration calorimetry (ITC). Herein we describe the development of meta- or ortho-substituted fluorinated benzenesulfonamides toward the highly potent compound 10 h, which exhibits an observed dissociation constant value of 43 pm and an intrinsic dissociation constant value of 1.1 pm toward CA IX, an anticancer target that is highly overexpressed in various tumors. Fluorescence thermal shift assays, ITC, and X-ray crystallography were all applied in this work. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Mechanical design and construction of a 200 mA, 100 keV, DC, negative ion accelerator

    International Nuclear Information System (INIS)

    Purgalis, P.; Anderson, O.A.; Cooper, W.S.; Cummings, C.; Koehler, G.W.; Matuk, C.A.; Wells, R.P.

    1987-01-01

    A volume production source and a 100 keV, dc, accelerator together with an additional, modular, 100 keV, electro static focused accelerator provide a starting point for a high energy H - /D - beamline (200 keV to 800 keV), intended for fusion energy applications. The 100 keV accelerator tests started in June 1987. The mechanical design and construction of the accelerator is described

  19. Radiation defects and electron disordering in proton-irradiated diamond films

    International Nuclear Information System (INIS)

    Maschenko, V.E.; Soloviev, G.G.

    1991-01-01

    The absorption spectra are studied in the region of the fundamental absorption band and its longwave boundary for the 0.6 μm thick diamond films deposited onto Al 2 O 3 single crystal underlayers and irradiated by 100 keV and 50 keV protons at fluences of 10 13 -10 16 cm -2 . The E 0 β (6.10-5.9eV) and E 0 α (5.51-5.43eV) maxima and the exponential tails towards lower energies are resolved in the spectra of initial films. The halfwidths of the maxima and a weak temperature dependence of their parameters and of the Urbach tail slope are indicative of disordering of the film structure. The intrinsic maxima near and above the indirect absorption boundary in diamond Γ 25 '-Δ are identified with transitions in the disordered cubic and hexagonal phases of the diamond films. The proton irradiation stimulates the intensity redistribution of the intrinsic maxima, the absorption enhancement, and the change of the Urbach tail slope. The character of radiolysis has been found to depend on the composition of the nonirradiated carbon films and on proton fluence. (author). 8 refs.; 3 figs

  20. Intra-articular sodium hyaluronate 2 mL versus physiological saline 20 mL versus physiological saline 2 mL for painful knee osteoarthritis: a randomized clinical trial

    DEFF Research Database (Denmark)

    Lundsgaard, C.; Dufour, N.; Fallentin, E.

    2008-01-01

    , Knee Injury and Osteoarthritis Outcome Score (KOOS), Osteoarthritis Research Society International (OARSI) criteria, and global assessment of the patient's condition. Results: The mean age of the patients was 69.4 years; 55% were women. The effects of hyaluronate 2 mL, physiological saline 20 m......Objective: Methodological constraints weaken previous evidence on intra-articular viscosupplementation and physiological saline distention for osteoarthritis. We conducted a randomized, patient- and observer-blind trial to evaluate these interventions in patients with painful knee osteoarthritis....... Methods: We centrally randomized 251 patients with knee ostcoarthritis to four weekly intra-articular injections of sodium hyaluronate 2 mL (Hyalgan(R) 10.3 mg/mL) versus physiological saline 20 mL (distention) versus physiological saline 2 mL (placebo) and followed patients for 26 weeks. Inclusion...