WorldWideScience
1

Real-time neutron diffraction measurements of the kinetics of first-order phase transitions  

International Nuclear Information System (INIS)

The wide-angle neutron diffractometer recently installed at the HFIR has the capability of performing time-resolved or time-slicing measurements. One of the interesting problem areas the authors have explored using this time-slicing function of the diffractometer is the kinetics of structural changes occurring after a temperature jump across a value at which a first-order phase transition occurs. Two measurements of this sort have been carried out: the phase III to II transition in RbNO_3 and the transition between the alpha and beta phases in Sn.

1985-03-01

4

Magnetic phase transition in UPd_2Si_2  

International Nuclear Information System (INIS)

... fields magnetic moments neel temperature neutron diffraction order-disorder

5

Solid-state amorphization of a quenched high-pressure GaSb phase studied by real-time neutron diffraction: evolution of the crystalline phase  

Energy Technology Data Exchange (ETDEWEB)

The amorphization of a quenched sample of the GaSb-II high-pressure phase was studied at ambient pressure by real-time neutron diffraction in the course of the sample heating from 100 K to room temperature at a rate of 0.4 K min{sup -1}. The transformation to the amorphous state begins at 140 K and is completed near room temperature. The {beta}-Sn type structure was shown to represent only the mean lattice of the high-pressure GaSb-II phase. The superstructure of this phase widely varied with temperature and is caused by the ordered displacement of atoms. The temperature range of the metastable crystalline phase relaxation is divided into three intervals according to the temperature dependence of the tetragonality ratio (c/a). At the boundaries of these temperature intervals, i.e. temperatures T = 170 and 230 K, two second-order phase transitions are observed. Anomalous heat and volumetric effects were ...

2009-01-28

6

Solid-state amorphization of a quenched high-pressure GaSb phase studied by real-time neutron diffraction: evolution of the crystalline phase  

International Nuclear Information System (INIS)

The amorphization of a quenched sample of the GaSb-II high-pressure phase was studied at ambient pressure by real-time neutron diffraction in the course of the sample heating from 100 K to room temperature at a rate of 0.4 K min-1. The transformation to the amorphous state begins at 140 K and is completed near room temperature. The ?-Sn type structure was shown to represent only the mean lattice of the high-pressure GaSb-II phase. The superstructure of this phase widely varied with temperature and is caused by the ordered displacement of atoms. The temperature range of the metastable crystalline phase relaxation is divided into three intervals according to the temperature dependence of the tetragonality ratio (c/a). At the boundaries of these temperature intervals, i.e. temperatures T = 170 and 230 K, two second-order phase transitions are observed. Anomalous heat and volumetric effects were observed ...

2009-01-28

9

Application of neutron diffraction in chemistry. Pt. 2  

Energy Technology Data Exchange (ETDEWEB)

This article provides a survey of neutron scattering experiments in condensed matter research, which are of interest to chemistry. The theoretical background has been treated in a previous issue. The present article consists of two parts. The first part exhibits the range of experimental possibilities by means of a few selected examples. The starting point is classical neutron diffraction by which the position of atomic nuclei may be determined. Additional information on the spatial distribution in the outer electron shells may be obtained via combined X-ray/neutron-diffraction experiments or via the diffraction of polarized neutrons. Progress in instrumentation, due to the development of more intense sources, has influenced especially the fields of small angle scattering and spectroscopy. The second part features domains of research of current interest, where a ...

1982-01-01

13

Relations between structural and superconducting properties of bulk and thin film high-T_c materials  

International Nuclear Information System (INIS)

The structural ordering of oxygen deficient and Co-doped YBCO (YBa_2Cu_3_-_yCo_yO_6_+_x) have been studied experimentally, and by computer simulations of the oxygen ordering in the basal plane of the structure. The calculations are based on the two-dimensional ASYNNNI model and its modifications. Good agreement is established between the ASYNNNI calculations and the experimentally observed structural properties of the double cell ortho-II structure and the oxygen disordering process from Co-doping into the basal plane. A model that relates the superconducting transition temperature T_c(x) of undoped YBCO and T_c(y) of Co-doped YBCO to the formation of specific domains of the two orthorhombic ordered oxygen phases, ortho-I and ortho-II, shows a close agreement with experimental T_c(x) and T_c(y) data of samples prepared under equilibrium conditions. The structural changes as a result of metal ion substitutions and oxidation/reduction processes ...

1984-02-13

14

The application of the neutron time-of-flight technique for real-time diffraction studies  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron powder diffraction and small-angle scattering techniques have been developed on the TOF diffractometer DN-2 at the IBR-2 pulsed reactor at JINR (Dubna) with a total flux on the sample of 10{sup 7} neutrons cm{sup -2}s{sup -1} and a resolution of about 1%. A special arrangement of the detector system ensures a high counting rate of diffracted neutrons. Depending upon sample type and experimental conditions, the measuring time t{sub s} of one neutron pattern varies from a few minutes to several seconds. The performance of the diffractometer is discussed and typical data are shown to demonstrate current achievements using real-time techniques at a pulsed reactor. (orig.).

1991-12-01

15

The application of the neutron time-of-flight technique for real-time diffraction studies  

International Nuclear Information System (INIS)

Real-time neutron powder diffraction and small-angle scattering techniques have been developed on the TOF diffractometer DN-2 at the IBR-2 pulsed reactor at JINR (Dubna) with a total flux on the sample of 10"7 neutrons cm"-"2s"-"1 and a resolution of about 1%. A special arrangement of the detector system ensures a high counting rate of diffracted neutrons. Depending upon sample type and experimental conditions, the measuring time t_s of one neutron pattern varies from a few minutes to several seconds. The performance of the diffractometer is discussed and typical data are shown to demonstrate current achievements using real-time techniques at a pulsed reactor. (orig.).

1991-12-01

16

Real-time neutron diffraction study of phase transitions in the Ti-D system after high pressure treatment  

International Nuclear Information System (INIS)

Phase transformations in TiD_#approx#_0_._7_5 subjected to high-pressure treatment were investigated by simultaneous real-time measurements of neutron diffraction and small-angle neutron scattering. The neutron spectra were taken on heating the samples in temperature ranges 100 to 300 K and 300 to 870 K. A sequence of structural transitions was observed, which involves 7 different phases and intermediate states with hcp, fcc, fco or bcc metal sublattices and hydrogen atoms. 30 refs., 9 figs., 1 tab.

1992-09-01

17

/sup 239/PuN powder neutron diffraction study  

Energy Technology Data Exchange (ETDEWEB)

A powder neutron diffraction study has been carried out on /sup 239/PuN, which was reported to be antiferromagnetic below T = 13 K. No magnetic ordering has been detected at 4 K, the limit of the magnetic ordering which could be detected being ..mu..sub(ord) = 0.25 ..mu..sub(B) per Pu atom. Moreover a neutron scattering length determination of /sup 239/Pu was performed which gave a value of bsub(239Pu) = (0.81 +- 0.05) x 10/sup -12/ cm at a neutron wavelength lambda = 1.219 A.

1984-10-01

18

Structure of molten alkali halides  

Energy Technology Data Exchange (ETDEWEB)

The results of X-ray and neutron diffraction experiments on molten alkali halides in which some data of our experiments by X-ray diffraction such as those of molten LiCl, NaCl, KCl, LiBr and KBr are included were summarized. The first peak positions in the radial distribution function in molten alkali halides by X-ray or neutron diffraction experiments are always longer than those by computer simulations and the differences of 0.1 -- 0.3 A exceed the experimental error. It seems to be due to the deformation of the electron shell. In the computer simulation, the shell model which has the spherical deformation was expected to have a closer value of the first peak position to the experimental one than the rigid ion model by taking the polarization of ions. However, no change in the first peak position was found. Therefore, the non-spherical deformation of electron shell at the point ...

1982-06-01

19

Structure of molten alkali halides  

International Nuclear Information System (INIS)

The results of X-ray and neutron diffraction experiments on molten alkali halides in which some data of our experiments by X-ray diffraction such as those of molten LiCl, NaCl, KCl, LiBr and KBr are included were summarized. The first peak positions in the radial distribution function in molten alkali halides by X-ray or neutron diffraction experiments are always longer than those by computer simulations and the differences of 0.1 -- 0.3 A exceed the experimental error. It seems to be due to the deformation of the electron shell. In the computer simulation, the shell model which has the spherical deformation was expected to have more closer value of the first peak position to the experimental one than the rigid ion model by taking the polarization of ions. However, no change in the first peak position was found. Therefore, the non-spherical deformation of electron shell at the point ...

1982-01-01

20

Diffraction Experiments at the IBR-2 Pulsed Reactor with Methane Cold Neutron Source  

CERN Document Server

A new methane cold neutron source has been tested at the IBR-2 pulsed reactor at the Frank Laboratory of Neutron Physics. In a paper the results of experiments at neutron diffractometers HRFD and DN-2 which are placed at the IBR-2 from the methane moderator side are given. A comparison with the results obtained with the conventional water comb-like moderator is performed. The perspectives of the cold source for various kinds of neutron diffraction experiments, including atomic and magnetic structural analysis and real time experiments are discussed. It is shown, that for a huge number of the experiments which are performing at both HRFD and DN-2 the methane cold neutron source provides the better conditions than water comb-like moderator.

2000-01-01

21

Neutron diffraction study of quasi-one-dimensional spin-chain compounds Ca3Co2-xFexO6  

International Nuclear Information System (INIS)

We report the results of the DC magnetization, neutron powder diffraction and neutron depolarization studies on the spin-chain compounds Ca3Co2-xFexO6 (x = 0, 0.1, 0.2 and 0.4). Rietveld refinement of neutron powder diffraction patterns at room temperature confirms the single-phase formation for all the compounds in rhombohedral structure with space group R3-barc. Rietveld refinement also confirms that Fe was doped at the trigonal prism site, 6a (0, 0, 1/4) of Co. The high temperature magnetic susceptibility obeys the Curie-Weiss law; the value of the paramagnetic Curie temperature (?p) decreases as the concentration of iron increases and it becomes negative for x = 0.4. No extra Bragg peak as well as no observable enhancement in the intensity of the fundamental (nuclear) Bragg peaks has been observed in the neutron diffraction patterns down ...

2008-11-01

22

Development of electronic imaging system for real time neutron radiography at TRIGA MK-II research reactor of AERE, Savar, Dhaka and utilization for research and industrial applications  

International Nuclear Information System (INIS)

The neutron radiography facility was installed at the tangential beam port of the 3 MW TRIGA MARK-II research reactor. In the facility only direct film neutron radiography method is being used. The project involves development of electronic imaging system for real time neutron radiography in the existing facility with the aim of utilizing it for research and industrial applications. In establishing the electronic imaging system for real time neutron radiography the improvements of existing facility were almost done during this period. In parallel, the former facility was used for the research: (a) A study of wood and wood plastic composites with and without additive by using film neutron radiography and (b) A study of jute reinforced polymer composites by using film neutron radiography technique. (author)

2008-09-01

23

Neutron stars in massive binary systems. I. Classification and evolution  

Energy Technology Data Exchange (ETDEWEB)

A study of the joint evolution of the normal- and neutron-star components of massive binaries opens with a classification scheme and the analytic expressions to be applied in Paper II for computer simulation of the observable properties of such systems.

1983-03-01

24

Some capabilities of neutron methods for investigating materials and components of devices used in hydrogen power engineering  

International Nuclear Information System (INIS)

Structural units of a hydrogen fuel cell whose characteristics are advisable to investigate by different neutron scattering methods are discussed. The results obtained with the use of Bragg diffraction and small-angle neutron scattering from fuel membranes, nanocarbon-platinum catalysts, and Zn_1_-_xCu_xO hydrogen storage systems are presented.

2007-05-01

25

Radiation damage on amorphous metals. [Helium ion, neutron and gamma ray irradiation  

Energy Technology Data Exchange (ETDEWEB)

The structural variations of amorphous metals, such as Pd/sub 80/Si/sub 20/, with irradiation of helium ion, neutron, and gamma ray have been mainly pursued by the method of X-ray diffraction and thermal analysis. It should be noticed that the amorphous metals show a radiation resistance, that is, no remarkable structural changes under helium ion, neutron, and gamma ray irradiation.

1982-04-01

26

Portable real time neutron spectrometry II  

International Nuclear Information System (INIS)

We describe the continued development of a portable, real-time neutron spectrometer. The spectrometer is composed of two distinct detector systems: a Helium 3 gas filled proportional counter for the lower neutron energy interval between 20 KeV and 2 MeV and a bulk silicon solid state detector for the higher energy interval between 2 MeV and 500 MeV. Modeling and experimental results with mono-energetic neutron beams are reported.

2000-01-19

27

Gamma-ray spectrometric analysis of nuclides formed in thorium by neutron irradiation  

International Nuclear Information System (INIS)

Gamma-ray spectrometric analysis was employed to determine the nuclides formed in thorium by neutron irradiation. Thorium sample was irradiated by neutron from a pure thermal neutron field, neutron field of Cd ratio of about 4, and epithermal neutron field, respectively. The former irradiation was carried out in a thermal neutron column provided for medical uses of neutrons, and the latters were done in the F-ring position of TRIGA II research reactor of Musashi Institute of Technology. The gamma-ray spectra were obtained and analyzed by employing a fully automatic gamma-ray analysis system named ''GAMA: giant frog:-SYSTEM'' developped by Musashi Institute of Technology. The formation of Pa-233 (U-233) was discussed quantitatively with respect to the difference of the neutron field. (author).

1985-02-01

28

Furnace for rapid change of temperature for neutron diffraction  

International Nuclear Information System (INIS)

A new furnace for neutron diffraction experiments is capable of heating and cooling a sample very rapidly. The rapid heating is done by two circular infrared lamps placed over and under a sample, whose radiation is roughly focused on the sample by a reflector. The rapid cooling is done by high-pressure gas blows against the sample from two circular nozzles which are also placed over and under the sample. This system enables us to obtain the heating rate of over 1000"0C/min and cooling rate of -500"0C/min for an alloy of 10 mm diameter and 30 mm length. The performance is sufficient to carry out some kinetics measurements in real-time neutron diffraction by the use of a position-sensitive detector. This kind of experiment is demonstrated by the observation of the relaxation process of order--disorder transitions in CuZn and Ni_3Mn alloys.

29

Residual stress measurements on a stress relieved Zircaloy-4 weld by neutron diffraction  

Energy Technology Data Exchange (ETDEWEB)

The macroscopic stress distribution across an annealed Zircaloy-4 gas tungsten arc weld was measured by neutron time-of-flight diffraction at the SMARTS diffractometer at Los Alamos National Laboratory. The stresses after annealing are about 40% lower than those in the same weld prior to heat treatment. The intergranular strains in the reference coupons, which give the macroscopic stress free lattice spacings, are consistent with the difference in cooling the strongly textured plate and the weakly textured weld.

2006-12-15

30

Real time neutron diffraction study on the intercalation of deuterobenzene into RbC/sub 24/  

Energy Technology Data Exchange (ETDEWEB)

The reaction of RbC/sub 24/ with C/sub 6/D/sub 6/ vapour was studied by neutron diffraction on a time scale of 5 min/spectrum. As for the reaction of KC/sub 24/, a second stage phase RbC/sub 24/(C/sub 6/D/sub 6/)sub(y) is initially formed and subsequently transformed into a first stage phase. Model calculations indicate that the benzene rings are canted against the graphite planes both in the first and in the second stage phase.

1983-11-01

31

A real time neutron diffraction study on the intercalation of deuterobenzene into RbC_2_4  

International Nuclear Information System (INIS)

The reaction of RbC_2_4 with C_6D_6 vapour was studied by neutron diffraction on a time scale of 5 min/spectrum. As for the reaction of KC_2_4, a second stage phase RbC_2_4(C_6D_6)sub(y) is initially formed and subsequently transformed into a first stage phase. Model calculations indicate that the benzene rings are canted against the graphite planes both in the first and in the second stage phase. (Auth.).

1983-01-01

32

Time-resolved neutron diffraction study of the superconducting phase formation process in the Bi(PB)-Sr-Ca-Cu-O system  

Energy Technology Data Exchange (ETDEWEB)

The results of real-time neutron diffraction measurements during the superconducting phase formation process in the Bi(Pb)-Sr-Ca-Cu-O system are reported. A Sr-Ca-Cu-O type precursor, with the same stoichiometry as the 2223 phase, was used as starting material, and the temperature range favorable to the formation of the 2223 phase was investigated. The diffraction patterns were processed by a multiphase Rietveld refinement. The formation and decomposition of the 2201 and 2212 phases were directly observed. Experimental evidence on the existence of a partially melted phase in the range 855-860[degrees]C, involved in the formation of the 2223 phase, is discussed. 14 refs., 9 figs., 1 tab.

1993-08-01

33

Time-resolved neutron diffraction study of the superconducting phase formation process in the Bi(PB)-Sr-Ca-Cu-O system  

International Nuclear Information System (INIS)

The results of real-time neutron diffraction measurements during the superconducting phase formation process in the Bi(Pb)-Sr-Ca-Cu-O system are reported. A Sr-Ca-Cu-O type precursor, with the same stoichiometry as the 2223 phase, was used as starting material, and the temperature range favorable to the formation of the 2223 phase was investigated. The diffraction patterns were processed by a multiphase Rietveld refinement. The formation and decomposition of the 2201 and 2212 phases were directly observed. Experimental evidence on the existence of a partially melted phase in the range 855-860 degrees C, involved in the formation of the 2223 phase, is discussed. 14 refs., 9 figs., 1 tab.

34

Nucleosynthesis in early supernova winds III: No significant contribution from neutron-rich pockets  

CERN Document Server

Recent nucleosynthesis calculations of Type II supernovae using advanced neutrino transport determine that the early neutrino winds are proton-rich. However, a fraction of the ejecta emitted at the same time is composed of neutron-rich pockets. In this paper we calculate the nucleosynthesis contribution from the neutron-rich pockets in the hot convective bubbles of a core-collapse supernova and show that they do not contribute significantly to the total nucleosynthesis.

2007-01-01

35

A real time neutron diffraction study on the reaction of AsF_5 with deuterated polyparaphenylene  

International Nuclear Information System (INIS)

The doping of deuterated polyparaphenylene [C_6D_4]sub(n) with AsF_5 has been investigated by real time neutron diffractometry at 100, 400 and 820 mbar AsF_5 pressure. The reaction appears to be diffusion controlled. Evidence for one doped phase with partial crystalline order was obtained. Structural considerations suggest two polymer chains plus one dopant ''string'' as the repetitive unit. (Auth.).

1982-01-01

36

A microscopic description of neutron-rich lithium isotopes  

International Nuclear Information System (INIS)

A unified calculation of neutron-rich isotopes in lithium is performed using the hyperspherical basis in which the underlying symmetry of each isotope exhibits a simple structure. The variation of the binding energy as a function of mass number is qualitatively reproduced, and the asymptotic of radial distribution of each isotope decreases exponentially. The form factors of the lithium isotopes are calculated and display diffraction minima. 27 refs., 3 figs., 3 tabs.

37

Palladium(II) and platinum(II) saccharinate complexes containing pyridine and 3-acetylpyridine: Synthesis, crystal structures, fluorescence and thermal properties  

British Library Electronic Table of Contents (United Kingdom)

New palladium(II) and platinum(II) complexes of saccharinate (sac), trans-[Pd(py)"2(sac)"2] (1), cis-[Pt(py)"2(sac)"2] (2), trans-[Pd(3-acpy)"2(sac)"2] (3) and cis-[Pt(3-acpy)"2(sac)"2] (4) (py=pyridine and 3-acpy=3-acetylpyridine) have been synthesized. Elemental analysis, UV-Vis, IR, NMR and TG/DTA characterizations have been carried out. The structures of 1-4 were determined by X-ray diffraction. The palladium(II) and platinum(II) ions are coordinated by two N-bonded sac ligands, and two nitrogen atoms of py or 3-acpy, forming a distorted square-planar geometry. The palladium(II) complexes (1 and 3) are trans isomers, while the platinum(II) complexes (2 and 4) are cis isomers. The mononuclear species in the solid state are connected by weak intermolecular C-H...O hydrogen bonds, C-H...@...

2011-01-01

38

Real time study of the crystallization of aluminium-base icosahedral phases by neutron powder diffraction  

International Nuclear Information System (INIS)

The thermal transformation of Al-base icosahedral phases was studied in-situ by real time neutron powder diffraction. Different compositions have been selected in order to vary the initial phase morphology and change the neutron scattering contrast between species. Alloys with low silicon and large aluminium contents produce first the orthorhombic O-Al_6Mn modification. In alloys with larger silicon content, the #alpha#-AlMnSi cubic phase appears soon after the beginning of the transformation but is still preceeded by O-Al_6Mn. Depending on compositions, the crystallization of the icosahedral phase is controlled either by the diffusion of Al through its interface with the residual fcc aluminium or that of Si within the bulk. The results are discussed in the light of current structural models. (author) 40 refs., 14 figs., 3 tabs.

1987-01-01

39

Polarized neutron diffraction study of CePd{sub 3}  

Energy Technology Data Exchange (ETDEWEB)

We have performed polarized neutron diffraction measurements on the intermediate valence compound CePd{sub 3} using the D3 spectrometer at the ILL. The results show that at low temperatures, 1.7 K, as well as at 100 K, the field-induced magnetic amplitudes measured in a field of 4.6 T could be interpreted in terms of two contributions: a 4f-type contribution with a Ce{sup 3+} form factor, and an extra delocalized contribution (relatively narrow in q-extent). In particular, we find that the values of the 4f moment deduced from the extrapolation of the neutron data to Q=0 are systematically lower than the values deduced from bulk magnetization measurements performed on the same sample. This difference can be ascribed to a possible positive polarization of the conduction band which is similar at both temperatures.

2004-07-15

40

Resent development by the use of neutron induced nuclear reaction  

International Nuclear Information System (INIS)

When the history of neutrons is considered, three large discoveries are recalled, that is, the discovery of neutrons by Chadwick in 1932, the discovery of the nuclear fission of uranium by Hahn and Strassmann in 1938, and the continuation of chain reaction in nuclear fission by Fermi and others in 1942. In neutron capture reaction, the reaction cross section can become very large. The fields of research, to which neutrons have contributed most as the experimental probe, are neutron activation analysis and neutron diffraction. The development of the prompt gamma ray analyzer at the JRR-3M in Japan Atomic Energy Research Institute is reported. This method eliminates the various defects in ordinary neutron activation analysis. By installing the cold neutron source with hydrogen cooling in the JRR-3M, ...

1992-01-01

41

Prediction and measurement of the neutron environment in OSURR experimental facilities following conversion to LEU  

International Nuclear Information System (INIS)

Neutron energy spectra were measured for two OSURR experimental facilities. The method of multiple foil activation was used with the SAND-II neutron spectrum unfolding code to obtain spectral data for the Central Irradiation Facility and Rabbit tube. Limited data was obtained for the thermal column using only gold foils. Calculations were made of the neutron environment in various locations using the MORSE code. A shift towards higher neutron energies was observed comparing results for LEU and HEU cores. A slight loss in total thermal neutron flux was measured for all positions. Calculational results show reasonable agreement with measured data.

1993-07-01

42

Crystalline O,O'-di-sec-butyl and O,O'-diethyl dithiophosphate platinum(II) complexes: Synthesis, 13C and 31P CP/MAS NMR, single crystal X-ray diffraction studies and thermal behaviour  

British Library Electronic Table of Contents (United Kingdom)

Crystalline bis(O,O'-di-sec-butyldithiophosphato)platinum(II) was prepared and studied by means of 13C, 31P CP/MAS NMR spectroscopy and single-crystal X-ray diffraction. The unit cell of the platinum(II) compound is comprised of one centrosymmetric mononuclear molecule [Pt{S2P(O-sec-C4H9)2}2], in which the dithiophosphate groups display structural equivalence in both 31P NMR and XRD data. A pair of the dithiophosphate ligands exhibit the same S,S'-bidentate chelating structural function and form two planar four-membered chelate rings, [PtS2P], in this molecule. The planar configuration of the [PtS4] chromophore in structure 1 is governed by the dsp2-hybrid state of platinum(II). The structural states of the dithiophosphate groups in two different samples of complex 1 (one crystallised from...

2011-01-01

43

Microstructure, texture and mechanical properties of the magnesium alloy AZ31 processed by ECAP  

Energy Technology Data Exchange (ETDEWEB)

To investigate the influence of equal channel angular pressing on the microstructure and texture of the magnesium alloy AZ31, electron backscattering diffraction and well as neutron diffraction experiments were carried out. Through these experiments it was possible to trace the microstructure and texture evolution with strain accumulated with the increasing number of equal channel angular pressing passes. It was further demonstrated by subsequent compression tests that the microstructural changes produced by equal channel angular pressing have a beneficial effect on both the compressive strength and ductility of AZ31. (orig.)

2008-01-15

44

Development of a neutron imaging facility at the CENM Al Maamora TRIGA  

Energy Technology Data Exchange (ETDEWEB)

The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computed tomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux ...

2009-07-01

45

Development of a neutron imaging facility at the CENM Al Maamora TRIGA  

International Nuclear Information System (INIS)

The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computed tomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux ...

2009-06-07

46

Comparison of SAND-II and FERRET  

Science.gov (United States)

A comparison was made of the advantages and disadvantages of two codes, SAND-II and FERRET, for determining the neutron flux spectrum and uncertainty from experimental dosimeter measurements as anticipated in the FFTF Reactor Characterization Program. This comparison involved an examination of the methodology and the operational performance of each code. The merits of each code were identified with respect to theoretical basis, directness of method, solution uniqueness, subjective influences, and sensitivity to various input parameters.

47

Ammonium azide: a commented example of an Ab initio structure (Re-) determination from X-ray powder diffraction  

Energy Technology Data Exchange (ETDEWEB)

The structure of ammonium azide (NH{sub 4})N{sub 3} was (re-)determined ab initio from x-ray powder diffraction experiment using synchrotron radiation. We tried to detail and comment the different steps involved in the structure determination. The compound crystallize in the orthorhombic Pmna space group (no.53) with a = 8.937(1) A, b= 3.8070(5) A, c = 8.664(1) A, V = 294.79(7) A{sup 3}; Z= 4. It was possible to locate and refine the hydrogen coordinates, in two different approaches, and to establish the H-bonds. The final structural parameters are in good agreement with previous results based on three-dimensional neutron diffraction. (Author)

2002-07-01

48

Ammonium azide: a commented example of an Ab initio structure (Re-) determination from X-ray powder diffraction  

International Nuclear Information System (INIS)

The structure of ammonium azide (NH_4)N_3 was (re-)determined ab initio from x-ray powder diffraction experiment using synchrotron radiation. We tried to detail and comment the different steps involved in the structure determination. The compound crystallize in the orthorhombic Pmna space group (no.53) with a = 8.937(1) A, b= 3.8070(5) A, c = 8.664(1) A, V = 294.79(7) A"3; Z= 4. It was possible to locate and refine the hydrogen coordinates, in two different approaches, and to establish the H-bonds. The final structural parameters are in good agreement with previous results based on three-dimensional neutron diffraction. (Author)

49

Hybrid porous phosphate heterostructures as adsorbents of Hg(II) and Ni(II) from industrial sewage  

British Library Electronic Table of Contents (United Kingdom)

Porous phosphate heterostructures (PPH), functionalized with different ratios of aminopropyl and mercaptopropyl groups, labelled as Nx=5,25,50-PPH and Sx=5,25,50-PPH, respectively, were tested as adsorbents for Ni(II) and Hg(II) found in industrial sewage from electroplating processes and button battery recycling. X-ray diffraction was used to study the structures. The specific surface area of the pristine material (PPH) was 620m^2g^-^1, whereas the specific surface areas of the modified mercaptopropyl (S5-PPH) and aminopropyl (N5-PPH) were 472 and 223m^2g^-^1, respectively. The adsorption data were fitted to a Langmuir isotherm model. The S5-PPH material was saturated by 120mmol Hg(II) per 100g of material, whereas for Ni(II) adsorption, N25-PPH material displayed the highest adsorption w...

2011-01-01

50

Stress measurements in welds: Problem areas  

Energy Technology Data Exchange (ETDEWEB)

There have been many stress measurements on welds by neutron diffraction over the past 20 years but there are still a number of serious experimental issues that are often not addressed. The primary fact is that the microstructure generally changes across the weld and accompanying this may be a change in the concentration of strengthening elements in solution. This will lead to a shift in lattice spacing which may be incorrectly interpreted as a strain. Secondly, a gradient of plastic deformation near the weld may be expected. Since plastic deformation by application of a stress always generates intergranular (type-2) strains this may lead to a range of intergranular effects superposed on the conventional weld-related strains. The effects are illustrated by neutron diffraction studies of Zr-4, ferritic and austenitic welds where chemistry, intergranular effects and crystallographic texture can all play a ...

2006-11-10

51

Real-time neutron diffraction study of crystallization kinetics in amorphous Fe_7_8B_1_3Si_9 alloy  

International Nuclear Information System (INIS)

The transformation from the as-quenched amorphous to the crystalline state in Fe_7_8B_1_3Si_9 alloy has been investigated using a new-type neutron diffractometer. The time resolved diffraction patterns clearly show that this alloy crystallizes into FeSi alloy and Fe_2B in that order. The time evolution of these crystalline phases can be analyzed by the Kolmogorov-Johnson-Mehl-Avrami equation with the exponent of about 2.5 over a wide temperature range. This suggests that the crystallization occurs by the diffusion-controlled growth with a constant nucleation rate. The scaling behavior in the crystallization kinetics is also discussed. (author).

1987-01-01

52

Real-time neutron diffraction study of crystallization kinetics in amorphous Fe/sub 78/B/sub 13/Si/sub 9/ alloy  

Energy Technology Data Exchange (ETDEWEB)

The transformation from the as-quenched amorphous to the crystalline state in Fe/sub 78/B/sub 13/Si/sub 9/ alloy has been investigated using a new-type neutron diffractometer. The time resolved diffraction patterns clearly show that this alloy crystallizes into FeSi alloy and Fe/sub 2/B in that order. The time evolution of these crystalline phases can be analyzed by the Kolmogorov-Johnson-Mehl-Avrami equation with the exponent of about 2.5 over a wide temperature range. This suggests that the crystallization occurs by the diffusion-controlled growth with a constant nucleation rate. The scaling behavior in the crystallization kinetics is also discussed.

1987-09-01

53

Neutron powder diffraction and solid-state deuterium NMR studies of Ca{sub 2}RuD{sub 6} and the stability of transition metal hexahydride salts  

Energy Technology Data Exchange (ETDEWEB)

The crystal structure of Ca{sub 2}RuD{sub 6} has been determined by neutron powder diffraction: space group Fm3m, K{sub 2}PtCl{sub 6} structure, as found for other hexahydride salts of group 8 metals with alkaline earth or lanthanide counter ions. No structural phase transition was observed between 340 K and 50 K. The deuterium nuclear quadrupole coupling constant, 54.7 kHz, leads to an ionic character of the Ru-D bond of 76%. The known trends in the behaviour of A{sub 2}MH{sub 6} salts are interpreted in terms of the ionization energies of the cation and the central metal atom.

2008-07-28

54

Neutron powder diffraction and solid-state deuterium NMR studies of Ca2RuD6 and the stability of transition metal hexahydride salts  

British Library Electronic Table of Contents (United Kingdom)

The crystal structure of Ca2RuD6 has been determined by neutron powder diffraction: space group Fm3m, K2PtCl6 structure, as found for other hexahydride salts of group 8 metals with alkaline earth or lanthanide counter ions. No structural phase transition was observed between 340K and 50K. The deuterium nuclear quadrupole coupling constant, 54.7kHz, leads to an ionic character of the Ru-D bond of 76%. The known trends in the behaviour of A2MH6 salts are interpreted in terms of the ionization energies of the cation and the central metal atom.

2008-01-01

55

Magnetic properties of ErPd_2Si_2 from magnetization Moessbauer and neutron diffraction measurements  

International Nuclear Information System (INIS)

Magnetization, neutron diffraction and "1"6"6Er Moessbauer measurements on ErPd_2Si_2 are reported. Below 4.8 K ErPd_2Si_2 orders AF with complex modulated magnetic structures, where the Er moments are aligned along the c-axis. At 1.5 K a squared structure with #mu#_E_r #approx# 7.8(1)#mu#_B is found while a saturation Er moment of 8.2(2)#mu#_B is inferred from the hyperfine field data. The temperature dependence of the Moessbauer spectra in the paramagnetic region is explained in the framework of a relaxation model implying excited crystal field levels. Its analysis is used to estimate the B"m_n CEF parameters. (orig.).

56

Characterization and residual stress analysis of wear resistant Mo thermal spray-coated steel gear wheels  

British Library Electronic Table of Contents (United Kingdom)

The determination of residual stress (RS) in case-hardened steel gear truck synchronisers coated with thermal sprayed molybdenum was carried out using neutron and synchrotron X-ray diffraction. Two samples with different coating thicknesses (about 120 ?m and 1.4 mm) and different steel substrates (16MnCr5 and SAE4140, respectively) were investigated. Microanalysis revealed substantial porosity in both samples and some debonding was observed between the thin coating and the substrate. The bulk hardness of the SAE 4140 proved to be much higher than the 16MnCr5 and the surface case-hardening increased it by a further 20%. The full three-dimensional stress depth-profile was determined by neutron diffraction (ND) in both the coatings and the substrates, while synchrotron radiation allowed a dep...

2006-01-01

57

Neutronics analysis of the 3MW TRIGA Mark-II research reactor by using SRAC code system  

British Library Electronic Table of Contents (United Kingdom)

This study deals with the neutronics analysis of the current core configuration of a 3MW TRIGA Mark-II research reactor at Atomic Energy Research Establishment (AERE), Savar, Dhaka, Bangladesh and validation of the results by benchmarking with the experimental, operational and available Safety Analysis Report (SAR) values. The comprehensive neutronics code system SRAC was used to develop a versatile and accurate full-core model of the TRIGA core. The model represents in detail all components of the core with literally no physical approximation. All fresh fuel and control elements as well as the vicinity of the core were precisely described. Cross-section data library generated from JENDL-3.2 were used. The validation of the model against benchmark experimental results is presented. The SRA...

2008-01-01

58

Coupled neutron - #gamma#-ray diffraction: A method for accurate measurement of strains. Application to the study of the ferroelectric phase transition of KH_2PO_4  

International Nuclear Information System (INIS)

A method that employs simultaneous neutron and #gamma#-ray diffraction techniques is proposed for accurate measurements of strains with or without an applied electric field (0-100 kV m"-"1). Instead of an absolute determination of the position of the neutron Bragg peak, a relative measurement of the neutron and #gamma# peak positions is used and allows a determination of the lattice-parameter changes with an accuracy of within 2 x 10"-"6. This technique avoids systematic errors originating in sample rotations by taking advantage of a reference directly related to the crystal lattice. The method appears to be particularly important for crystals that exhibit structural phase transitions, as demonstrated by the measurement of the strain U_x_x in KH_2PO_4 crystals as a function of temperature and applied electric field. In this case the errors would amount to #+-#20%. The results demonstrate the need to ...

1987-12-01

59

Pyrolysis of dichlorodithiourea cadmium(II)  

Energy Technology Data Exchange (ETDEWEB)

By means of infrared spectroscopy, x-ray diffraction, and differential thermal analysis, the authors investigate the pyrolysis of dichlorodithiourea cadmium, the vapor phase epitaxy of the cadmium sulfide film, and the composition of the solid and gaseous pyrolysis products. Those products are found to include the thiocyanates of guanidine, ammonium, and hydrogen along with cadmium oxides and sulfates and hydrochloric acid.

1987-02-20

60

Real time neutron transmission investigation of the austenite-bainite transformation in grey iron  

Energy Technology Data Exchange (ETDEWEB)

The first successful application of a new method to investigate phase transformations in real time, like the decomposition of austenite into bainite in grey iron, is described. During the ongoing transformation, transmission spectra of thermal neutrons, which contain Bragg edges corresponding to the crystal structure of the transforming phases, are recorded. By evaluating the height of these Bragg edges, which is a measure of the volume fraction of the phase, at different transformation times, the transformation can be followed in-situ in a time resolved manner. The method is compared to other previously used methods (micrographs, dilatometry, diffraction techniques); also a summary and an outlook are given. ((orig.))

1994-06-01

61

Real time neutron transmission investigation of the austenite-bainite transformation in grey iron  

International Nuclear Information System (INIS)

The first successful application of a new method to investigate phase transformations in real time, like the decomposition of austenite into bainite in grey iron, is described. During the ongoing transformation, transmission spectra of thermal neutrons, which contain Bragg edges corresponding to the crystal structure of the transforming phases, are recorded. By evaluating the height of these Bragg edges, which is a measure of the volume fraction of the phase, at different transformation times, the transformation can be followed in-situ in a time resolved manner. The method is compared to other previously used methods (micrographs, dilatometry, diffraction techniques); also a summary and an outlook are given. ((orig.)).

1994-01-01

62

Real time neutron diffraction study on the reaction of AsF/sub 5/ with deuterated polyparaphenylene  

Energy Technology Data Exchange (ETDEWEB)

The doping of deuterated polyparaphenylene (C/sub 6/D/sub 4/)sub(n) with AsF/sub 5/ has been investigated by real time neutron diffractometry at 100, 400 and 820 mbar AsF/sub 5/ pressure. The reaction appears to be diffusion controlled. Evidence for one doped phase with partial crystalline order was obtained. Structural considerations suggest two polymer chains plus one dopant ''string'' as the repetitive unit.

1982-07-01

63

Neutron diffraction study of 5f itinerant antiferromagnet UPtGa{sub 5} and UNiGa{sub 5}  

Energy Technology Data Exchange (ETDEWEB)

Magneto-striction and magnetic form factors in 5f itinerant antiferromagnets UNiGa{sub 5} and UPtGa{sub 5} are studied by means of neutron scattering. Remarkable magneto-striction was observed around T{sub N}, indicating large spin-orbit coupling in the itinerant system. The orbital magnetic moment is found to be strongly suppressed due to the hybridization of uranium 5f with Ga-4p electron.

2003-05-01

64

Synthesis, structure and characterisation of the n=4 Aurivillius phase Bi5Ti3CrO15  

International Nuclear Information System (INIS)

The n=4 Aurivillius phase, Bi5Ti3CrO15, was synthesised by solid state reaction. Rietveld analysis of high resolution neutron diffraction data demonstrated this material to adopt the polar space group A21am at room temperature, transforming to the aristotype I4/mmm structure above 650 oC. This phase transition is coincident with an anomaly in DSC signal and relative permittivity, which are characteristic of a ferroelectric-paraelectric phase transition. Bi5Ti3CrO15 exhibits paramagnetic behaviour at low temperature, with short range antiferromagnetic interactions, but no evidence for long range magnetic ordering. This is considered a consequence of significant disorder of Ti and Cr over the available octahedral sites, as demonstrated by analysis of neutron diffraction data. -- Graphical abstract: We report here the synthesis, structure and characterisation of the n=4 Aurivillius phase Bi5Ti3CrO15. ...

2011-02-01

65

Real time neutron diffraction experiments using Bragg edges  

Energy Technology Data Exchange (ETDEWEB)

Time resolved phase transition and strain experiments have been performed on the millisecond time scale using a Bragg-edge transmission technique that has been developed at the Los Alamos National Laboratory. The precision with which lattice parameters can be determined from edge positions is sufficient to perform high-resolution strain measurements in uniaxial stress.

1995-12-31

66

Real time neutron diffraction experiments using Bragg edges  

International Nuclear Information System (INIS)

Time resolved phase transition and strain experiments have been performed on the millisecond time scale using a Bragg-edge transmission technique that has been developed at the Los Alamos National Laboratory. The precision with which lattice parameters can be determined from edge positions is sufficient to perform high-resolution strain measurements in uniaxial stress.

1994-12-02

67

Radial distribution functions of amorphous silicon  

Energy Technology Data Exchange (ETDEWEB)

Substantial changes in the radial distribution function of amorphous Si films have been observed in neutron-diffraction studies. The spectra indicate changes in short-range order associated with an approx.11% modification in the bond-angle distribution width. The results allow the first direct comparison of structural and vibrational Raman probes of variations in local order in thin-film amorphous solids. Good agreement is obtained between the measured bond-angle variation and that based on Raman estimates.

1989-03-15

68

Emesis ED50 of neutron irradiation and prophylactic effectiveness. Final report, 1 January 1979-31 December 1984  

Energy Technology Data Exchange (ETDEWEB)

Two neutron emesis experiments were conducted at the Armed Forces Radiobiology Research Institute (AFRRI). In both experiments (described as Phase I and Phase II) the radiation dose required to cause emesis in 50% of subjects (ED50) was determined for both neutron reactor and gamma reactor source radiation. Emesis onset, offset and duration times post-exposure are reported. Neutrons were maximized from the reactor by passing the beam through a 15.25 cm (6 in.) thick lead wall to filter out gamma photons. Gamma rays were maximized by thermalizing neutrons in 30.5 cm (12 in.) of water, then absorbing the thermal neutrons in a gadolinium-cadmium shield. In Phase I, 28 dogs were exposed to radiation: 12 were exposed to gamma photons at the rate of 0.69 Gy/min and 16 were exposed to neutrons at 1.2 Gy/min. In Phase II, 58 ...

1985-08-01

69

Recent developments and applications for the University of Texas thermal neutron imaging facility  

Energy Technology Data Exchange (ETDEWEB)

The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits ...

2001-07-01

70

ANALYSIS OF ACCELERATOR BASED NEUTRON SPECTRA FOR BNCT USING PROTON RECOIL SPECTROSCOPY  

Energy Technology Data Exchange (ETDEWEB)

Boron Neutron Capture Therapy (BNCT) is a promising binary treatment modality for high-grade primary brain tumors (glioblastoma multiforme, GM) and other cancers. BNCT employs a boron-10 containing compound that preferentially accumulates in the cancer cells in the brain. Upon neutron capture by {sup 10}B energetic alpha particles and triton released at the absorption site kill the cancer cell. In order to gain penetration depth in the brain Fairchild proposed, for this purpose, the use of energetic epithermal neutrons at about 10 keV. Phase I/II clinical trials of BNCT for GM are underway at the Brookhaven Medical Research Reactor (BMRR) and at the MIT Reactor, using these nuclear reactors as the source for epithermal neutrons. In light of the limitations of new reactor installations, e.g. cost, safety and licensing, and limited capability for modulating the reactor based ...

1998-11-06

71

Testing measurements at horizontal channels of the MARIA reactor performed using neutron spectrometers; Pomiary testowe przy kanalach poziomych reaktora MARIA wykonane przy uzyciu spektrometrow neutronow  

Energy Technology Data Exchange (ETDEWEB)

By means of neutron diffraction, using the standard polycrystalline sample of Al{sub 2}O{sub 3}, measurements on three (of four spectrometers) already installed in the front of horizontal channels of MARIA reactor have been performed. Basing on these experiments as well as on activation measurements carried out earlier, the fluxes of monoenergetic neutrons have been estimated. These experiments allowed to determine (for a given geometry and kind of monochromators chosen) the resolution efficiency of instruments and high order contamination in the reflected beam. With the help of polycrystalline vanadium and TbBr{sub 3} sample, the possibility of studies using the inelastic scattering process have been tested. (author) 7 refs, 15 figs, 7 tabs

1997-12-31

72

Studies of interlayer magnetic coupling in all-semiconductor superlattices by means of neutron scattering techniques  

International Nuclear Information System (INIS)

An overview on neutron scattering studies of ferromagnetic and antiferromagnetic all-semiconductor superlattices is presented. Diffraction experiments on MnTe/CdTe, MnTe/ZnTe and EuTe/PbTe superlattices show pronounced correlations between the MnTe and EuTe layers across the non-magnetic spaces, even though these layers are antiferromagnetic and the systems are nearly-insulating. Current theory status of these systems is discussed. Diffractometry and reflectometry data from EuS/PbS superlattices reveal pronounced antiferromagnetic coupling between the ferromagnetic EuS block. First polarized neutron reflectometry data from superlattices prepared of a novel ferromagnetic 'spintronics' material, Ga(Mn)As are also presented. (author)

2001-09-23

73

Neutron magnetic scattering studies on ferromagnetism in potassium nanoclusters arrayed in zeolite A-Trial experiments  

Energy Technology Data Exchange (ETDEWEB)

Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic scattering is estimated to be extremely weak and higher S/N of {approx}10{sup 4} or more is required to detect the ...

2009-02-21

74

Neutron magnetic scattering studies on ferromagnetism in potassium nanoclusters arrayed in zeolite A-Trial experiments  

International Nuclear Information System (INIS)

Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic scattering is estimated to be extremely weak and higher S/N of ?104 or more is required to detect the magnetic ...

2009-02-21

75

Study of ethanol-lysozyme interactions using neutron diffraction  

International Nuclear Information System (INIS)

Single-crystal neutron diffraction has been used to observe the interactions between deuterated ethanol (CD3CD2OH) and lysozyme in triclinic crystals of hen egg white lysozyme soaked in 25% (v/v) ethanol solutions. A total of 6047 observed reflections to a resolution of 2 A were used, and 13 possible ethanol sites were identified. The three highest occupied sites are close to locations for bromoethanol found in an earlier study by Yonath et al. [Yonath, A., Podjarny, A., Honig, B., Traub, W., Sielecki, A., Herzberg, O., and Moult, J. (1978) Biophys. Struct. Mech. 4, 27-36]. Structure refinements including a model for the flat solvent lead to a final crystallographic agreement factor of 0.097. Comparison with earlier neutron studies on triclinic lysozyme showed that neither the molecular structure nor the thermal motions were affected significantly by the ethanol. A detailed analysis of the ethanol-lysozyme contacts showed ...

76

Principles of the measurement of residual stress by neutron diffraction  

Energy Technology Data Exchange (ETDEWEB)

The presence of residual stresses in engineering components can significantly affect their load carrying capacity and resistance to fracture. In order to quantify their effect it is necessary to know their magnitude and distribution. Neutron diffraction is the most suitable method of obtaining these stresses non-destructively in the interior of components. In this paper the principles of the technique are described. A monochromatic beam of neutrons, or time of flight measurements, can be employed. In each case, components of strain are determined directly from changes in the lattice spacings between crystals. Residual stresses can then be calculated from these strains. The experimental procedures for making the measurements are described and precautions for achieving reliable results discussed. These include choice of crystal planes on which to make measurements, extent of masking needed to identify a suitable sampling ...

1996-11-01

77

FEM Analysis and Measurement of Residual Stress by Neutron Diffraction on the Dissimilar Overlay Weld Pipe  

International Nuclear Information System (INIS)

Much research has been done to estimate the residual stress on a dissimilar metal weld. There are many methods to estimate the weld residual stress and FEM (Finite Element Method) is generally used due to the advantage of the parametric study. And the X-ray method and a Hole Drilling technique for an experimental method are also usually used. The aim of this paper is to develop the appropriate FEM model to estimate the residual stresses of the dissimilar overlay weld pipe. For this, firstly, the specimen of the dissimilar overlay weld pipe was manufactured. The SA 508 Gr3 nozzle, the SA 182 safe end and SA376 pipe were welded by the Alloy 182. And the overlay weld by the Alloy 52M was performed. The residual stress of this specimen was measured by using the Neutron Diffraction device in the HANARO (High-flux Advanced Neutron Application ReactOr) research reactor, KAERI (Korea Atomic Energy Research Institute). Secondly, FEM ...

2010-10-01

78

An investigation of the isothermal creep response of Al-based composites by neutron diffraction  

Energy Technology Data Exchange (ETDEWEB)

Discontinuously reinforced aluminium-based composites containing particulate or whisker SiC reinforcements at different volume fractions, were produced via a powder-route. Isothermal creep tests have been carried out at 270, 300 and 320 C. During these tests axial and transverse strains were monitored using a non-contacting laser scanning extensometer arrangement. At the same time neutron diffraction has been used to measure the elastic phase strain evolution with composite creep deformation. It was found that after the initial loading the phase strains remained essentially constant during primary and secondary creep. This indicates that the initial matrix/reinforcement inelastic misfits remain largely unchanged, probably due to the setting up of a dynamic equilibrium between misfit generation and stress relaxation. For each system, the neutron data has been combined with Eshelby modelling to obtain a measure of the load ...

2000-05-31

79

Uncertainty analysis in fusion activation calculations: Application to the waste disposal assessment of HYLIFE-II structure  

International Nuclear Information System (INIS)

A computational procedure is proposed to perform uncertainty analysis for the calculation of the isotopic inventory and radiological quantities obtained as a linear function of it, due to uncertainties in the activation cross sections. The method is applied to determine the uncertainty of the calculated shallow burial index (SBI) from activated type 304 stainless steel (SS) in the most neutron-exposed zone of the HYLIFE-II vessel structure. Results are obtained by means of an element-by-element study. Some other types of steel are also investigated for comparison purposes. The SS304 is confirmed to be the most promising steel option. 16 refs., 2 tabs.

1996-06-16

80

Proceedings of the first analysis meeting on JUPITER-II Program  

Energy Technology Data Exchange (ETDEWEB)

The JUPITER-II Program is the Joint Physics Large Heterogeneous Core Critical Experiments Program between the U.S. Department of Energy (US DOE) and PNC, Japan. The experiments began in May 1982 and ended in April 1984, as a part of the ZPPR-13 program. The ZPPR-13 is a series of critical assemblies designed to study the fundamental neutronic behavior of large, radially-heterogeneous LMFBR cores. This report describes the results of analysis of ZPPR-13A and preliminary analysis of ZPPR-13B, and some topics of recent activities in fast reactor physics.

1984-12-31

81

CRC handbook of nuclear reactors calculations. Vol. II  

International Nuclear Information System (INIS)

This handbook breaks down the complex field of nuclear reactor calculations into major steps. Each step presents a detailed analysis of the problems to be solved, the parameters involved, and the elaborate computer programs developed to perform the calculations. This book bridges the gap between nuclear reactor theory and the implementation of that theory, including the problems to be encountered and the level of confidence that should be given to the methods described. Volume II: Monte Carlo Calculations for Nuclear Reactors. In-Core Management of Four Reactor Types. In-Core Management in CANDU-PHW Reactors. Reactor Dynamics. The Theory of Neutron Leakage in Reactor Lattices. Index.

82

Thermal neutron capture gamma-rays  

Energy Technology Data Exchange (ETDEWEB)

The energy and intensity of gamma rays as seen in thermal neutron capture are presented. Only those (n,..cap alpha..), E = thermal, reactions for which the residual nucleus mass number is greater than or equal to 45 are included. These correspond to evaluations published in Nuclear Data Sheets. The publication source data are contained in the Evaluated Nuclear Structure Data File (ENSDF). The data presented here do not involve any additional evaluation. Appendix I lists all the residual nuclides for which the data are included here. Appendix II gives a cumulated index to A-chain evaluations including the year of publication. The capture gamma ray data are given in two tables - the Table 1 is the list of all gamma rays seen in (n,..gamma..) reaction given in the order of increasing energy; the Table II lists the gamma rays according to the nuclide.

1983-01-01

83

Plasma dynamics in the PF-1000 device under full-scale energy storage: II. Fast electron and ion characteristics versus neutron emission parameters and gun optimization perspectives  

International Nuclear Information System (INIS)

Electron and ion beam dynamics of the PF-1000 facility were investigated for the first time at its upper energy limit (?1 MJ) in relation to neutron emission, the pinch's plasma ('target') characteristics and some other parameters with the help of a number of diagnostics with ns temporal resolution. Special attention was paid to the temporal and the spatial cross correlations of different phenomena. Results of these experiments are in favour of a neutron emission model based on ion beam-plasma interaction with three important features: (1) the plasma target is hot and confined during a few 'inertial confinement times'; (2) the ions of the main part of the beam are magnetized and entrapped around the pinch plasma target for a period longer than the characteristic time of the plasma inductive storage system and (3) ion-ion collisions (both fusion collisions, due to head-on impacts and Coulomb collisions) are responsible for ...

2007-06-21

84

Characterization of Radiation Instruments at the Summit of Mt. Fuji  

International Nuclear Information System (INIS)

The opportunity of exposure to high-energy radiation up to GeV is increasing as in civilian aircrafts and at particle accelerators. The transport of such energetic particle is still difficult to describe precisely and thus verification by measurement using a well characterized instrument is indispensable for reliable dosimetry. However, no reference calibration field has been established for the high-energy range. We thus propose to use a facility at the summit of Mt. Fuji (3776 m in altitude; N35.36o, E138.73o), the highest place in Japan, for characterization of radiation instruments that are possibly used in high-energy radiation fields. For demonstration of the effectiveness, two moderator-type neutron monitors (NCN1 and WENDI-II) having different energy response functions were employed for cosmic-ray neutron measurements in the summer of 2009. In comparison with numerically simulated values, it was found that the ...

2010-12-01

85

Structure determination and investigation on cytotoxicity of potassium dichlorido(l-prolinato)platinate(II) versus chlorido(dimethyl sulfoxide)(l-prolinato)platinum(II) complex -In vitro antitumor deactivation by Cl^-/dmso ligand exchange  

British Library Electronic Table of Contents (United Kingdom)

Potassium dichlorido(l-prolinato)platinate(II), K[PtCl"2(l-pro"?"H)] (1), and chlorido(dimethyl sulfoxide)(l-prolinato)platinum(II), [PtCl(l-pro"?"H)(dmso)] (2), were synthesized by ligand substitution reactions. Both complexes were characterized by ^1H, ^1^3C, and ^1^9^5Pt NMR spectroscopy, elemental analysis, and HR-ESI-MS. The molecular structures of 1 and 2 were determined by single crystal X-ray diffraction, proving bidentate coordinated l-prolinato ligand and SP-4-4 configuration of 2a. With the help of DFT calculations stability of possible isomers of 1 and 2 was studied. A considerable difference in the in vitro cytotoxicity of 1 versus 2a (exchange of one chlorido ligand by dmso) against four human cancer cell lines was found.

2011-01-01

86

Experimental studies of compact real-time neutron dosimeters  

International Nuclear Information System (INIS)

Full text: Semiconductor detectors coated with boron or lithium compounds have been studied for neutron detection for decades but, until recently, have been limited to thermal neutron detection efficiencies of less than 5%. We reported previously on development and simulation studies of perforated detectors whose perforations are filled with neutron-reactive material in order to produce higher detection efficiencies. Incorporation of bare and cadmium-backed detectors into battery-powered devices with low-power electronics enables us to produce compact personal neutron dosimeters that provide LED readout of counts, which can be related approximately to neutron dose. We report here on experimental studies with such compact devices; devices capable of direct readout in dose units are anticipated. The thermal and epithermal neutron flux densities from the tangential ...

2008-06-01

87

Forthcoming (n, #gamma#) measurements on the Fe and Ni isotopes at CERN n_TOF  

International Nuclear Information System (INIS)

An overview of the past, present and future research activities at the CERN neutron time of flight facility n_TOF is given, with special focus on the astrophysical aspects. During the first campaign (Phase I), neutron capture cross sections of relevance for several aspects of the s-process nucleosynthesis have been measured. A second campaign has recently started (Phase II), aiming at the study of the weak s-process component via accurate (n,#gamma#) measurements of the Fe and Ni isotopes. Some changes in the facility will allow us to perform these measurements with improved experimental conditions.

2010-01-01

88

Internal strain and texture evolution during deformation twinning in magnesium  

Energy Technology Data Exchange (ETDEWEB)

The development of a twinned microstructure in hexagonal close-packed rolled magnesium compressed in the in-plane direction has been monitored in situ with neutron diffraction. The continuous conversion of the parent to daughter microstructure is tracked through the variation of diffraction peak intensities corresponding to each. Approximately 80% of the parent microstructure twins by 8% compression. Elastic lattice strain measurements indicate that the stress in the newly formed twins (daughters) is relaxed relative to the stress field in the surrounding matrix. However, since the daughters are in a plastically 'hard' deformation orientation, they quickly accumulate elastic strain as surrounding grains deform plastically. Polycrystal modeling of the deformation process provides insight about the crystallographic deformation mechanism involved.

2005-06-15

89

Chemical isomeric effects on propanol glassy structures  

Energy Technology Data Exchange (ETDEWEB)

We have studied the structure of both propanol isomers in their glassy and crystalline states by neutron diffraction. The glass-transition temperatures of 1- and 2-propanol are about 98 and 115 K, respectively and, surprisingly, even larger differences are observed for the melting temperatures of the stable crystals, which are 148 and 185 K, respectively. Their supercooled liquid phases show rather different relaxation spectra, 1-propanol manifesting strong deviations from Debye behavior, whereas 2-propanol shows a far weaker effect. We discuss the spectra obtained for the static structure factor and the static pair correlation function D(r). There is a noticeable difference in the position of the first sharp diffraction peak, which clearly indicates a density change, well correlated with the period of the intermolecular oscillations shown by D(r). (orig.)

2002-07-01

90

Chemical isomeric effects on propanol glassy structures  

International Nuclear Information System (INIS)

We have studied the structure of both propanol isomers in their glassy and crystalline states by neutron diffraction. The glass-transition temperatures of 1- and 2-propanol are about 98 and 115 K, respectively and, surprisingly, even larger differences are observed for the melting temperatures of the stable crystals, which are 148 and 185 K, respectively. Their supercooled liquid phases show rather different relaxation spectra, 1-propanol manifesting strong deviations from Debye behavior, whereas 2-propanol shows a far weaker effect. We discuss the spectra obtained for the static structure factor and the static pair correlation function D(r). There is a noticeable difference in the position of the first sharp diffraction peak, which clearly indicates a density change, well correlated with the period of the intermolecular oscillations shown by D(r). (orig.)

91

Effect of headgroup dissociation on the structure of Langmuir monolayers  

Energy Technology Data Exchange (ETDEWEB)

The authors present results of grazing incidence X-ray diffraction studies concerning the effect of pH (and thus, of headgroup dissociation) on Langmuir monolayers of fatty acids, in the absence of any divalent cations in the aqueous subphase. An increase in pH transforms the distorted-hexagonal S phase first to the partially disordered Rotator-I phase with less distortion, and then to the completely disordered Rotator-II phase with an undistorted hexagonal structure. The S-Rotator-I and Rotator-I-Rotator-II transitions are pushed to lower temperatures with increase in pH. The fact that the effects of pH increase are almost identical to the effects of increasing temperature indicates the important role of headgroup-headgroup interactions in these monolayer phases.

2000-02-08

92

Neutron irradiation of superconducting compounds  

International Nuclear Information System (INIS)

The effects of neutron irradiation on the superconducting and normal state properties of alloys and compounds are presented. Particular emphasis is placed on the A-15 compounds where the effects of neutron irradiation on Tsub(c), Hsub(c_2), long range order parameter and lattice parameter are described. Large depressions (up to 80%) in Tsub(c) are observed for all the A-15 compounds studied with the exception of Mo_3Os where much smaller decreases in Tsub(c) are seen. Along with the decrease in Tsub(c) and increase in lattice parameter, the degree of long range order, as measured by X-ray and neutron diffraction, decreases. Also presented are the results of isothermal and isochronal anneals up to 900"0C. The unirradiated value of Tsub(c) can be restored by annealing, and for those systems where measurements have been made, recovery of the lattice parameter and order parameter also takes place. The ...

93

Stabilization of high-temperature antimony oxide with molybdenum incorporation. Structure of Mo-doped Sb/sub 2/O/sub 4/ by powder neutron diffraction and extended X-ray absorption fine structure spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

It has been discovered that the presence of MoO/sub 3/ lowers the ..cap alpha..-..beta.. transition in Sb/sub 2/O/sub 4/ from 935 to 850/sup 0/C with concurrent dissolution of Mo in the high-temperature (..beta..) form. The structure of Mo-doped ..beta..-Sb/sub 2/O/sub 4/ has been investigated by powder neutron diffraction, extended X-ray absorption fine structure (EXAFS) and Raman spectroscopies, and scanning-electron microscopy (SEM). Cell parameters: a = 12.0571 (12) A, b = 4.8335 (1) A, c = 5.3838 (6) A, ..beta.. = 105.579 (5)/sup 0/, monoclinic, space group C2/c, Z = 4. Combining the results of these techniques leads to the hypothesis that Mo is located interstitially within channels of electron density in the Sb/sub 2/O/sub 4/ structure with concurrent vacancy of two Sb/sup III/ atoms. There is no apparent oxygen deficiency in the resulting structure. 25 references, 6 figures, 3 tables.

1985-10-09

94

Neutron diffraction and magnetization studies of pseudoternary HoRh_2_-_xPd_xSi_2 solid solutions (0#<=#x<2)  

International Nuclear Information System (INIS)

Neutron powder diffraction and magnetometric studies of the HoRh_2_-_xPd_xSi_2 series of solid solutions (x=0, 0.5, 0.75, 1.0, 1.5, 1.8) are reported. The intermetallics investigated crystallize in the body-centred-tetragonal ThCr_2Si_2-type structure (space group I4/mmm). All the samples order antiferromagnetically at low temperatures. For low values of the dilution parameter x a simple collinear antiferromagnetic structure of the AFI type is stable. Below T_N the magnetic moments are parallel to the c-axis and then, below T_t, deflect forming an angle #psi# with the c-axis. Further replacement of Rh by Pd results in the development of a sine-wave-modulated magnetic structure with one two-component propagation vector and magnetic moments in the basal plane. For x=1.8 a sine-wave-modulated structure similar to that reported for HoPd_2Si_2 (i.e. with a two-component propagation vector and magnetic moments parallel to the b-axis) was found. ...

2002-06-03

95

Magnetic ordering in CeM_2Si_2 (M = Ag,Au,Pd,Rh) compounds as studied by neutron diffraction  

International Nuclear Information System (INIS)

We report the results of neutron-diffraction experiments on CeM_2Si_2 (M = Ag,Au,Pd,Rh) which were performed to explore the role of valence fluctuations and 4f hybridization in the magnetic ordering of cerium compounds. All four order antiferromagnetically, the first three exhibiting structures consisting of ferromagnetic layers with moments perpendicular to the layers, which are believed to be characteristic of 4f-4f interactions mediated through hybridization with conduction electrons. CePd_2Si_2 has an anomalously small moment (0.62#mu#/sub B/) in the ordered state. CeAg_2Si_2 exhibits an incommensurate longitudinal, static magnetization wave with moment and propagation direction along the a axis. The fourth compound, CeRh_2Si_2, has the highest known transition temperature (39 K) reported for cerium ordering; it exhibits another second-order transition at 27 K to a complex commensurate structure with modulated moments. The results are discussed in terms of the ...

96

Magnetic ordering in CeM/sub 2/Si/sub 2/ (M = Ag,Au,Pd,Rh) compounds as studied by neutron diffraction  

Energy Technology Data Exchange (ETDEWEB)

We report the results of neutron-diffraction experiments on CeM/sub 2/Si/sub 2/ (M = Ag,Au,Pd,Rh) which were performed to explore the role of valence fluctuations and 4f hybridization in the magnetic ordering of cerium compounds. All four order antiferromagnetically, the first three exhibiting structures consisting of ferromagnetic layers with moments perpendicular to the layers, which are believed to be characteristic of 4f-4f interactions mediated through hybridization with conduction electrons. CePd/sub 2/Si/sub 2/ has an anomalously small moment (0.62..mu../sub B/) in the ordered state. CeAg/sub 2/Si/sub 2/ exhibits an incommensurate longitudinal, static magnetization wave with moment and propagation direction along the a axis. The fourth compound, CeRh/sub 2/Si/sub 2/, has the highest known transition temperature (39 K) reported for cerium ordering; it exhibits another second-order transition at 27 K to a complex commensurate structure with modulated moments. ...

1984-03-01

97

CRSS of {gamma}/{gamma}' phases from in situ neutron diffraction of a directionally solidified superalloy tension tested at 900 deg. C  

Energy Technology Data Exchange (ETDEWEB)

Neutron diffraction was used to monitor elastic strains during in situ tension testing of a directionally solidified (DS) superalloy at 900 deg. C. Changes in misfit and thermal expansion coefficients of individual phases were obtained. In the {gamma} phase, it is demonstrated that elastic strains saturate at 350 MPa, which is well below the yield strength of the alloy. This is interpreted as the onset of dislocation glide through less stressed vertical channels. The critical resolved shear stress (CRSS) of {gamma} is found to be 143 {+-} 11 MPa, in agreement with a calculated CRSS that is dominated by Orowan bowing of dislocations through nanoscale-wide {gamma} channels. This provides confirmation of Orowan bowing in plasticity/creep of the {gamma} phase. Implications of CRSS and misfit in a 'threshold stress' for creep and rafting are discussed. The CRSS of {gamma}' is found to be consistent with pairwise ...

2008-09-15

98

Position sensitive detection of individual nuclear particle scintillations using image intensifier tubes  

International Nuclear Information System (INIS)

An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).

1996-01-01

99

Structural Phase Transition in AuZn Alloys  

Energy Technology Data Exchange (ETDEWEB)

AuxZn1-x alloys undergo a shape memory martensitic transformation whose temperature and nature (continuous or discontinuous) is strongly composition dependent. Neutron diffraction experiments were performed on single crystals of x=50 and 52 to explore the structural changes occurring at the transition temperature. A transverse modulation with wavevector q0=(1/3,1/3,0) develops below the transition temperature, with no observable change in lattice parameter. However, the Bragg peak width shows a broadening suggesting an unresolved rhombohedral distortion similar to what has been observed in NiTi-Fe alloys.

2009-05-03

100

Magnetic structure of Ce(Ru_0_._9_6Pd_0_._0_4)_2Si_2  

International Nuclear Information System (INIS)

The magnetic structure of a tetragonal Ce(Ru_0_._9_6Pd_0_._0_4)_2Si_2 single crystal, determined by neutron diffraction measurements, is similar to that observed in Rh doped alloys. The magnetic moments are oriented and modulated along the c-axis. Here the wave vector is incommensurate: k=(0,0,0.38). At 1.5 K, the moment is estimated to about 0.3 #mu#_B. Magnetization, magnetoresistance and Hall effect measurements performed on this alloy are also reported. (orig.).

101

Crystal chemistry of hydroxyl and water in silicate minerals. Final technical report  

Energy Technology Data Exchange (ETDEWEB)

This was a project to investigate the crystal chemistry of OH and H{sub 2}O substitution in silicate minerals by use of X-ray and neutron diffraction methods combined with IR spectroscopy and to interpret and generalize the results using an electrostatic model for these mineral structures. Using these data together with published H position data electrostatic parameters for H sites were calculated from a simple electrostatic model. The data were then used to refine the model for incorporation of H into the wadsleyite structure. This has led to recent work on the synthesis and characterization of hydrous wadsleyites.

1998-06-01

102

Structural changes in amorphous Pd_8_0Si_2_0 and Pd_7_7_._5 Cu_6 Si_1_6_._5 alloys caused by neutron irradiation  

International Nuclear Information System (INIS)

The present work is to study effects of neutron irradiation on the structure of amorphous Pb_8_0 Si_2_0 and Pd_7_7_._5 Cu_6 Si_1_6_._5 alloys by using X-ray diffraction techniques. differential scanning calorimertry (DSC) and internal friction measurements. The irradiation will produce obvious changes in the pair correlation function g(r) and radial distribution function RDF (r). The increase of crystallization temperature (Tx) and enthalpy of two specimens were found by DSC measurements after irradiation. The results of internal friction measurement show that the internal friction of the irradiated Pd_8_0Si_2_0 alloy is higher than that of the unirradiated in the temperature range of Tneutron irradiation are discussed in terms of the concepts of density fluctuation defects (p) and shear stress fluctuation defects (#iota#).

103

New neutron simulation capabilities provided by the Sandia Pulse Reactor (SPR-III) and the Upgraded Annular Core Pulse Reactor (ACPR)  

Science.gov (United States)

The paper briefly describes the nuclear reactor facilities at Sandia Laboratories which are used for simulating nuclear weapon produced neutron environments. These reactor facilities are used principally in support of continuing R and D programs for the Department of Energy/Office of Military Application (DOE/OMA) in studying the effects of radiation on nuclear weapon systems and components. As such, the reactors are available to DOE and DOD agencies and their contractors responsible for the radiation hardening of advanced nuclear weapon systems. Emphasis is placed upon two new reactor simulation sources; the Sandia Pulse Reactor-III (SPR-III) Facility which enhances the neutron exposure volume capabilities over those presently available with the existing SPR-II Facility, and the Upgraded Annular Core Pulse Reactor (ACPR) Facility which enhances the neutron exposure capabilities over those of the former ...

1978-07-01

104

Radiation imposed limits on superconducting magnets: A data base for copper stabilizers  

Energy Technology Data Exchange (ETDEWEB)

Two of eight differently prepared copper stabilizer samples, previously irradiated in the RTNS-II at LLNL, the IPNS-1 and the BSR at ORNL, have been irradiated to a fluence of 1.33 /times/ 10/sup 22/ n/m/sup 2/ at RTNS-II. During the course of the irradiation the samples were periodically removed (without warming) for measurements of the transverse magnetoresistance and returned for continued irradiation. This experiment extends the range of neutron-irradiation-induced resistivity by a factor of five over the previous experiments. A simple model is developed which reproduces the magnetoresistance results of all the experiments to an accuracy of 2.5%. 13 refs., 6 figs.

1987-10-28

105

Burnup analysis and in-core fuel management study of the 3MW TRIGA MARK II research reactor  

British Library Electronic Table of Contents (United Kingdom)

The principal objective of this study is to formulate an effective optimal fuel management strategy for the TRIGA MARK II research reactor at AERE, Savar. The core management study has been performed by utilizing four basic types of information calculated for the reactor: criticality, power peaking, neutron flux and burnup calculation. This paper presents the results of the burnup calculations for TRIGA LEU fuel elements. The fuel element burnup for approximately 20 years of operation was calculated using the TRIGAP compute code. The calculation is performed in one-dimensional radial geometry in TRIGAP. Inter-comparison of TRIGAP results with other two calculations performed by MVP-BURN and MCNP4C-ORIGEN2.1 show very good agreement. Reshuffling at 20,000MWh step provides the highest core l...

2008-01-01

106

Characterization and properties of monoammine nitroimidazole complexes of platinum (PtCl sub 2 (NH sub 3 )(NO sub 2 Im)). Crystal and molecular structure of cis-Amminedichloro(1-((((2-hydroxyethyl)amino)carbonyl)methyl)-2-nitroimidazole)platinum(II)  

Energy Technology Data Exchange (ETDEWEB)

The characterization of monoammine(nitroimidazole)platinum(II) complexes of structure (PtCl{sub 2}(NH{sub 3})(NO{sub 2}Im)) (NO{sub 2}Im = 1-((((2-hydroxyethyl)amino)carbonyl)methyl)-2-nitroimidazole, Etanidazole (I), 1-(2-nitro-1-imidazolyl)-3-methoxy2-propanol, Misonidazole (II), and 1-(2-hydroxyethyl)-2-methyl-5-nitroimidazole, Metronidazole (III)) is reported. Both is cis and trans isomers may be isolated for II and III. The crystal structure of cis-amminedichloro(1-((((2-hydroxyethyl)amino)carbonyl)methyl)-2-nitroimidazole)platinum(II) has been determined by X-ray diffraction. The crystals are orthorhombic, space group Pnab with cell dimensions a = 14.867 (7) {angstrom}, b = 9.915 (5) {angstrom}, c = 19.015 (9) {angstrom}, and Z = 8. The structure was refined to R = 0.062 and R{sub w} = 0.052. Platinum has the expected square-planar coordination. The Pt-Cl bond trans to the ...

1991-11-27

107

Experience and recent developments in nuclear forensics at the Institute of Isotopes  

International Nuclear Information System (INIS)

Full text: Based on experience with nuclear material confiscated in Hungary from illicit trafficking activities in the nineties it has been decided that traditional gamma-spectrometry should be complemented by destructive analytical techniques. The 17/1996 (I. 31.) Korm. Governmental Decree delegated the identification, categorization and characterization tasks to the Institute of Isotopes, Budapest. Routine gamma-spectrometric methods have been further developed aiming at the i) age (production date) determination of seized samples and complete (nondismountable) uranium-bearing items (such as fresh fuel bundles and fission chambers) by HRGS technique, ii) improvement of measurement accuracy and reliability. Starting in 2005 mass spectrometry (ICP-SFMS) and scanning electron microscopy have been implemented to characterize nuclear samples in more detail and to analyze environmental samples both for isotopic and elemental composition focusing on long-lived ...

108

Inelastic Neutron Scattering on an Mn10 Supertetrahedron: Assessment of Exchange Coupling Constants, Ferromagnetic Spin Waves and an Analogy to the Hckel Method  

British Library Electronic Table of Contents (United Kingdom)

Abstract The synthesis, crystal structure and magnetic characterisation by magnetisation and inelastic neutron scattering (INS) of a mixed-valent Mn10 supertetrahedral aggregate [MnIII6MnII4(4-O)4(3-N3)3(3-Br)(Hmpt)6(Br)]Br0.7(N3)0.3-2-MeOH-3-MeCN (1) (H3mpt=3-methylpentan-1,3,5-triol) is reported. The magnetic core of the molecule can be described as an octahedron of six S=2 MnIII ions with four faces, each capped by a S=5/2 MnII ion such as to form the supertetrahedron. Unlike most related complexes, the molecular symmetry is slightly reduced from approximately Td to C3. The magnetic data reveal a total spin of S=22 in the ground state due to ferromagnetic exchange couplings within the molecule. The combined INS and magnetic data permits the accurate determination of the exchange couplin...

2011-01-01

109

Study on the spatial structure of annomuricatin A, a cyclohexapeptide from the seeds of Annona muricata  

British Library Electronic Table of Contents (United Kingdom)

A cyclic hexapeptide, annomuricatin A (the molecular formula: C27H38N6O7), was isolated from the seeds of Annona muricata. The types and sequence of the amino acids were confirmed by X-ray diffraction analysis. The stereochemistry of the title cyclopeptide was clarified by X-ray crystallographic study. The backbone contains two b-turns, one is type I b-turn and the other is type II, which are stabilized by two transannular 41 backbone hydrogen bonds between Ala and Phe. There are intermolecular hydrogen bonds between the cyclopeptide and the solvent molecules which maintained the steady spatial arrangement in crystal.

2007-01-01

110

Evaluation of thin Pd, Pt and Ni silicides Schottky barriers for silicon solar cells. Large area uniform growth of Si layer by solid phase epitaxy (II). Final report  

Science.gov (United States)

The phase stability of silicides of Ni, Pt and Pd in contact with single crystal or amorphous silicon is examined. The presence of a particular silicide phase is identified by X-ray diffraction, and Rutherford backscattering is used to study composition. It is concluded that Pt or Pd silicides are suitable for Schottky barriers. Layers of silicon can be grown quickly by solid phase epitaxy at temperatures of 300-500C and using an intermediate metal film. Experimental results are reported. Doped layers have been obtained which have electrical characteristics suitable for the junctions in solar cells. The effects of impurities and orientation of the substrate on the growth kinetics are discussed.

111

Emittance of boehmite and alumina films on 6061 aluminium alloy between 295 and 773 K  

International Nuclear Information System (INIS)

The total hemispherical emittance of an oxide film that formed on 6061-T6 aluminium alloy parts in the Tower Shielding Reactor-II at Oak Ridge National Laboratory was measured from 295 to 773 K using an emissometer and/or a calorimeter. The emittance of this film was critically needed for heat transfer calculations in a simulated loss-of-coolant accident of the reactor. X-ray diffraction analysis identified the film as boehmite (Al_2O_3 x H_2O), which dehydrated to alumina (Al_2O_3) upon heating above 473 K. The measured emittances for the alumina film are in excellent agreement with published values for anodized aluminum films and for bulk alumina. Published values of the emittance of boehmite could not be found for comparison, but evidence is presented that some anodization processes for aluminum yield boehmite and not alumina films.

1991-01-01

112

Synthesis, Crystal Structure and Spectroscopic Properties of an Oximato Bridged Cu(II) Dimer  

British Library Electronic Table of Contents (United Kingdom)

Schiff-base condensation of a equimolar proportion of diacetyl-monoxime monohydrazone and 1-methylimidazole-2-carboxaldehyde in methanol gives rise to the imidazole azine, 3-(1-methylimidazol-2-yl)methylenehydrazonobutan-2-one oxime(HL). Reaction of 1:1 stoichiometric proportion of HL with copper(II)perchlorate hexahydrate in methanol yields a dimeric oximato bridged copper compound, [Cu2L2(H2O)2](ClO4)2 (1). The compound is characterized by C, H and N analyses, FT-IR, ESI?MS, conductivity measurement, UV?Vis spectra and X-ray single crystal diffraction. The title compound (1) crystallizes in the monoclinic space group P21/c with a?=?6.8533 (8), b?=?18.413 (2), c?=?11.7399 (14) ?, ??=?93.685 (2)?, V?=?1478.4 (3) ?3 and Z?=?2. The geometry around each copper center is distorted square pyram...

2011-01-01

113

Performance of the upgraded LTP-II at the ALS Optical Metrology Laboratory  

Energy Technology Data Exchange (ETDEWEB)

The next generation of synchrotrons and free electron laser facilities requires x-ray optical systems with extremely high performance, generally of diffraction limited quality. Fabrication and use of such optics requires adequate, highly accurate metrology and dedicated instrumentation. Previously, we suggested ways to improve the performance of the Long Trace Profiler (LTP), a slope measuring instrument widely used to characterize x-ray optics at long spatial wavelengths. The main way is use of a CCD detector and corresponding technique for calibration of photo-response non-uniformity [J. L. Kirschman, et al., Proceedings of SPIE 6704, 67040J (2007)]. The present work focuses on the performance and characteristics of the upgraded LTP-II at the ALS Optical Metrology Laboratory. This includes a review of the overall aspects of the design, control system, the movement and measurement regimes for the stage, and analysis of the performance by a ...

2008-07-14

114

Novel non-discoid chiral copper(II)-salen type [N2O2] donor Schiff base complexes with a cyclohexane diamine spacer: synthesis, electrochemistry, columnar mesomorphism and DFT study  

British Library Electronic Table of Contents (United Kingdom)

A series of new non-discoid chiral copper(ii)-salen type complexes, [Cu((4-CnH2n+1O)2salen)], n = 14, 16, 18 and salen = N,N'-cyclohexane bis (salicylideneiminato), containing 4-substituted alkoxy tails in the side aromatic rings and a cyclohexane spacer, have been prepared and their mesogenic properties investigated. The compounds were characterised by Fourier transform infra-red spectroscopy, 1H and 13C nuclear magnetic resonance spectroscopy, UV-vis spectroscopy and fast atom bombardment mass spectrometry. Mesomorphic properties of these compounds were studied by polarising optical microscopy, differential scanning calorimetry and X-ray diffraction (XRD). The ligands are non-mesogenic but the complexes exhibited enantiotropic rectangular columnar mesophases (Colr) with extended temperat...

2011-01-01

115

Magnetism of DyPd_2Si_2 and ErPd_2Si_2  

International Nuclear Information System (INIS)

Neutron diffraction and magnetometric measurements on polycrystalline samples of DyPd_2Si_2 and ErPd_2Si_2 were carried out in the temperature range from 2 to 293 K. Both compounds show tetragonal ThCr_2Si_2 type crystal structure and order at 12 K in a sine modulated magnetic structure with propagation vectors k=[0.609,0,0.155] and [0.575, 0, 0.083] respectively. The oscillatory character of magnetic order found in RPd_2Si_2 (R=Tb-Er) compounds suggests exchange interaction described by the RKKY model to be dominant, but the non-monotonic dependence of respective Neel temperatures on the number of f-electrons indicates the influence of a crystalline electric field (CEF) on the magnetic behaviour in this series. (orig.).

116

Fluoride phosphate Li{sub 2}CoPO{sub 4}F as a high-voltage cathode in Li-ion batteries  

Energy Technology Data Exchange (ETDEWEB)

As a new high-voltage cathode candidate for post 4V cathodes, ordered-olivine LiCoPO{sub 4} and fluoride phosphate, Li{sub 2}CoPO{sub 4}F were synthesized by solid-state reaction. Their structures were identified by neutron diffraction. The 5V discharge profiles were demonstrated using coin-type cells. Two important issues for commercial use, metal dissolution and oxygen release at elevated temperatures, were also tested with an atomic absorption spectrophotometer and differential scanning calorimeter, respectively. (author)

2005-08-26

117

Research and development of neutron radiography in IAERU  

Energy Technology Data Exchange (ETDEWEB)

In the Institute for Atomic Energy, Rikkyo University, just after the TRIGA-2 research reactor of 100 kW has attained the criticality, the cylindrical box for neutron radiography (NR) irradiation was made in the attached pool, and the research on NR was started in 1961. Thereafter in 1985, the vertical irradiation pipe was installed in the reactor tank, and the experiment for collecting the basic data was begun. In 1986, based on the obtained data, the NR irradiation facility on full scale was installed in No. 2 tangential horizontal experimental hole. As the main NR irradiation facilities, the vertical neutron irradiation pipe, the use of which is stopped now, the NR facility using the horizontal experimental hole (RUR/N2), the irradiation facility and ancillary facilities such as beam shutter, beam catcher and hoist are described. As the main equipments for NR, the imaging apparatuses of cooled type CCD, SIT and superhigh sensitivity, the ...

1995-03-01

118

Optical Diffraction Studies of Muscle Fibers  

UK PubMed Central (United Kingdom)

A new technique to monitor light diffraction patterns electrically is applied to frog semitendinosus muscle fibers at various levels of stretch. The intensity of the diffraction lines, sarcomere length...Full Text Available

1973-09-01

119

The influence of a seed crystal on the texture of a bulk YBaCuO specimen  

International Nuclear Information System (INIS)

To investigate the dependence of the local texture of parts of an YBaCuO specimen on the distance of the seed crystal from the position of the part of the specimen, a very good textured YBaCuO specimen was cut into 9 rectangular pieces and into 12 boundary pieces of the cylindric original specimen. From the individual parts of the YBaCuO specimen the texture was measured by neutron diffraction at the Geesthacht reactor with an equal area raster. The grid width was 1 up to 10 deviation from the cylinder axis of the original YBaCuO cylinder and 2 from 10 deviation until 20 deviation. From the sum of the counted neutrons on small circles on the pole sphere the individual values of the distributions of the angular deviations of the c-axes of the crystalline domains from the cylinder axis have been calculated. The mean deviation of the c-axes from the axis of the original cylinder increases from the inner part with the seed ...

120

Structure of Ce-doped Bi/sub 2/(MoO/sub 4/)/sub 3/ as determined by neutron profile refinement  

Energy Technology Data Exchange (ETDEWEB)

The structure of Bi/sub 1.8/Ce/sub 0.2/(MoO/sub 4/)/sub 3/ has been refined with powder neutron diffraction data by the Rietveld method. The structure can be derived by severely distorting the scheelite structure (AMO/sub 4/) and is perhaps better written A/sub (2/3)/phi/sub (1/3)/MO/sub 4/, where phi = cation vacancy. Of the two bismuth atom sites, cerium preferentially occupies the more symmetric of the two (Bi(2) in the structure) with some cerium found in the scheelite subcell vacancies also. This site preference is understood by examining the symmetries of the two Bi sites. Crystal data: monoclinic, space group P2/sub 1//c, Z = 4, a = 7.697(2), b = 11.535(3), c = 11.944(3), ..beta.. = 115.19.

1984-05-01

121

A quantitative structural analysis of the low temperature phase of lithium-7  

International Nuclear Information System (INIS)

Calculations in "7Li have been carried out for the differential coherent elastic scattering cross-section of thermal neutrons at a fixed scattering angle #theta#_0(148"o) and varying the energy of incident neutrons (or corresponding d-spacings). The results are reported, as variations of the ratio #SIGMA#_0"c"o"h (#theta#_0, d)/#SIGMA#_0"c"o"h (#theta#_0) with d-spacing, at atmospheric pressure and at two temperatures, 80 and 20 K. The calculations at 80 K correspond to BCC lithium whereas at 20 K all the possible crystallographic structures of polytype lithium (BCC, 9R, HCP and FCC) were considered. On comparing our results with the time-of-flight (TOF) measurements of Berliner et al. (Physical Review, B40, 12086, 1989) we find that up to 80 K lithium-7 does not undergo any martenistic transformation whereas the structural state at 20 K can be described by the co-existence of the original BCC phase with 9R, HCP and FCC closed packed ...

122

Comparison and Physical Interpretation of MCNP and TART Neutron and Gamma Monte Carlo Shielding Calculations for a Heavy-Ion ICF System  

Energy Technology Data Exchange (ETDEWEB)

For heavy-ion beam driven inertial fusion ''liquid-protected'' reactor designs such as HYLIFE-II, a mixture of molten salts made of F{sup 10}, Li{sup -6}, Li{sup 7} and Be{sup 9} (called flibe) allows small chambers and final-focus magnets closer to the target with superconducting coils suffering higher radiation damage, though they can stand only a certain amount of energy deposited before quenching. This work has been primarily focusing on verifying that total energy deposited by fusion neutrons and induced gamma rays remain under such limit values and the final purpose is the optimization of the shielding of the magnetic lens system from the points of view of the geometrical configuration and of the physical nature of the materials adopted. The system is analyzed in terms of six geometrical models going from simplified up to much more realistic representations of a system of 192 beam lines, each focused by ...

2002-07-01

124

Plasma dynamics in PF-1000 device under full-scale energy storage: I. Pinch dynamics, shock-wave diffraction, and inertial electrode  

International Nuclear Information System (INIS)

This paper (paper I) presents the first part of results obtained with the PF-1000 facility for the first time at its upper energy limit (?1 MJ). Special attention is paid here to plasma ('pinch') dynamics, which was investigated in relation to its electro-technical and radiation (especially neutron) characteristics with the help of a number of diagnostics, both time-integrated and with nanosecond temporal resolution. In these methods we utilized a Rogowski coil for the routine electro-technical measurements, visual multi-frame and streak cameras, soft x-ray pin-hole multi-frame cameras, PIN-diode assembly and PM tubes with scintillators for soft and hard x-rays as well as for neutron investigations together with a set of activation counters. In particular, the temporal cross correlation of different phenomena taking place during the discharge was investigated. The pinch's longevity appears to be 10-15 times larger than the ideal ...

2007-04-07

125

Grazing incidence X-ray diffraction and neutron reflection studies of semi-crystalline polymer surfaces and interfaces[Polymers; Crystallisation behaviour  

Energy Technology Data Exchange (ETDEWEB)

This thesis is concerned with the crystallisation behaviour of polymers near to a free surface or a buried interface. The properties of polymers are expected to differ significantly near to an interface (either with air or another polymer), due to the contributions of (a) chain configurations induced at the interface, and (b) different mobilities between interfacial regions and the bulk of the sample. For a semi-crystalline polymer, properties such as the degree of crystallinity and the crystallisation kinetics may be enhanced near to a free surface. Grazing incidence x--ray diffraction (GIXD) is used to investigate such effects in poly(ethylene terphthalate) (PET), showing that a lower crystallisation temperature is obtained at the surface, and the crystallisation kinetics are faster at the surface for all temperatures. It is proposed that in thin films of PET, this surface-induced ordering provides nucleation sites for crystallisation in the bulk. GIXD is also ...

2002-07-01

126

Carbon fibers and composites modified by intercalation  

International Nuclear Information System (INIS)

The aim of this paper was to describe ability to intercalation of laboratory prepared carbon composites and their constituents. In work the following materials were tested; pinch-based fibres of P-120 and K-1100 manufacturer's designations, carbon matrix and resulting composites. To prepare a matrix of composites, phenol-formaldehyde resin (Z) and pinch-based precursor (PAK) were used. After initial carbonization, the carbon matrix was heated to 2150 "oC i to improve ability to the future intercalation. Three kinds of composites (P/Z, K/Z and K/PAK), with two directional reinforcement (2D), were prepared. All carbon samples were intercalated with copper chloride(II). To study the structure of all materials, before and after intercalation, X-ray diffraction method was used. It enabled to measure microstructure parameters (L_c and L_a), interplanar distance (d_0_0_2) thickness of an intercalation layer (d_i). Before intercalation, graphite fibers ...

127

Spectroscopic Studies of Phosphazene Polymers Containing Photoluminescent Metal Complexes  

British Library Electronic Table of Contents (United Kingdom)

Abstract A series of small phosphazene ligands with pendant 6-phenyl-2,2--bipyridyl moieties, namely L1 [N3P3(OPh)5(OPhbpyPh)], L2 [N3P3(biph)2(OPhbpyPh)2], L3 [N3P3(tBubiph)2(OPhbpyPh)2], L4 [N3P3(biph)2(OPhbpyPh)Cl] and L5 [N3P3(biph)2(OPhbpyPh)(OPh)] [OPhbpyPh = 4-(4-phenoxy)-6-phenyl-2,2--bipyridine, OPh = phenoxy, biph = 2,2--oxybiphenyl and tBubiph = 4,4--di-tert-butyl-2,2--oxybiphenyl], have been used to synthesise the new cyclometallated palladium(II) and platinum(II) complexes [(L1-H)PdCl], [(L1-H)PtCl], [(L1-H)(PdCl)2], [(L3-H)(PdCl)2], [(L4-H)PtCl], [(L5-H)PtCl] and the rhenium(I) complex [L5Re(CO)3Cl]. Single-crystal X-ray diffraction analysis was performed on the free ligand L2 and the palladium complexes [(L1-H)PdCl] and [(L3-H)(PdCl)2]. In both PdII complexes, the metal cent...

2011-01-01

128

Vibrational dynamics of hydrogen and deuterium in crystalline Pd_9Si_2  

International Nuclear Information System (INIS)

Crystalline Pd_9Si_2 possesses an orthorhombic structure (Pnma) that is characterized by augmented triangular prismatic coordination of the silicon atoms such as that which occurs in several metal-rich transition-metal silicides. Recent neutron diffraction results for deuterium solution in this crystalline phase have indicated that deuterium occupies only one type of interstice, i.e., a Pd-defined pyramidal site in a four-fold position situated on a quadrilateral face of an empty triangular prism. The vibrational dynamics of both H and D located at this site were investigated by neutron vibrational spectroscopy. The low-temperature density of states (DOS) of H in Pd_9Si_2H_0_._2_5 indicates three well-defined optic vibrations located at 49.4, 67.2 and 75.5 meV. The lowest-energy feature is assigned to the normal-mode vibration perpendicular to the pyramidal base and the two higher-energy features are assigned to the two ...

1996-08-25

129

Crystalline electric field of the rare-earth nickelates RniO{sub 3} (R = Pr, ND, Sm, Eu, and Pr{sub 1-x}La{sub x},0 {le} X {le} 0.7) determined by inelastic neutron scattering.  

Energy Technology Data Exchange (ETDEWEB)

The rare-earth based nickelates RNiO{sub 3} (R = Pr, Nd, Sm, Eu, and Pr{sub 1-x}La{sub x}, 0{<=}x{<=}0.7) were studied by inelastic neutron scattering. Energy splittings due to the crystalline-electric-field (CEF) interaction at the R{sup 3+} site within the electronic ground-state J multiplet (for R = Pr, Nd, and Pr{sub 1-x}La{sub x}) as well as within the two lowest-lying J multiplets (for R = Sm and Eu) were directly observed, and the corresponding CEF energy-level schemes were reconstructed. The latter were rationalized in terms of CEF parameters, which vary smoothly over the rare-earth series and give magnetic properties associated with the R sublattice in agreement with results from neutron powder diffraction experiments. Across the metal-insulator transition, a continuous change in the electronic part of the CEF parameters is observed. However, an attempt to quantify a charge transfer from the observed ...

1999-12-01

130

Crystalline electric field of the rare-earth nickelates RNiO{sub 3} (R=Pr, Nd, Sm, Eu, and Pr{sub 1-x}La{sub x}, 0{<=}x{<=}0.7) determined by inelastic neutron scattering  

Energy Technology Data Exchange (ETDEWEB)

The rare-earth based nickelates RNiO{sub 3} (R=Pr, Nd, Sm, Eu, and Pr{sub 1-x}La{sub x}, 0{<=}x{<=}0.7) were studied by inelastic neutron scattering. Energy splittings due to the crystalline-electric-field (CEF) interaction at the R{sup 3+} site within the electronic ground-state J multiplet (for R=Pr, Nd, and Pr{sub 1-x}La{sub x}) as well as within the two lowest-lying J multiplets (for R=Sm and Eu) were directly observed, and the corresponding CEF energy-level schemes were reconstructed. The latter were rationalized in terms of CEF parameters, which vary smoothly over the rare-earth series and give magnetic properties associated with the R sublattice in agreement with results from neutron powder diffraction experiments. Across the metal-insulator transition, a continuous change in the electronic part of the CEF parameters is observed. However, an attempt to quantify a charge transfer from the observed ...

1999-12-01

131

Crystalline electric field of the rare-earth nickelates RNiO_3 (R=Pr, Nd, Sm, Eu, and Pr_1_-_xLa_x, 0#<=#x#<=#0.7) determined by inelastic neutron scattering  

International Nuclear Information System (INIS)

The rare-earth based nickelates RNiO_3 (R=Pr, Nd, Sm, Eu, and Pr_1_-_xLa_x, 0#<=#x#<=#0.7) were studied by inelastic neutron scattering. Energy splittings due to the crystalline-electric-field (CEF) interaction at the R"3"+ site within the electronic ground-state J multiplet (for R=Pr, Nd, and Pr_1_-_xLa_x) as well as within the two lowest-lying J multiplets (for R=Sm and Eu) were directly observed, and the corresponding CEF energy-level schemes were reconstructed. The latter were rationalized in terms of CEF parameters, which vary smoothly over the rare-earth series and give magnetic properties associated with the R sublattice in agreement with results from neutron powder diffraction experiments. Across the metal-insulator transition, a continuous change in the electronic part of the CEF parameters is observed. However, an attempt to quantify a charge transfer from the observed variation of the CEF parameters in an ...

1999-12-01

132

X-ray micro-spectroscopy: a tool for micro-scale radionuclide speciation in heterogeneous nuclear waste repository materials  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: Large-scale problems such as nuclear waste disposal are increasingly recognized to be interconnected to small scale-mechanisms. Thus, synchrotron-based high-resolution analytical X-ray probes become important tools for exploring the micro-scale chemical reactivity of heterogeneous barrier materials used in nuclear waste repositories. In this study the layout of the micro-XAS beamline at the Swiss Light Source (SLS) will be presented. The beamline is optimized towards micro beam experiments ({approx}1 x 1 {mu}m{sup 2}) in the hard-X-ray regime (4 - {approx}22 keV) and allows to combine micro X-ray fluorescence (micro-XRF), micro X-ray absorption spectroscopy (micro- XAS), and micro X-ray diffraction (micro-XRD) investigations with radioactive samples. Furthermore, the potential of micro-XRF/XAS/XRD for acquiring spatially resolved molecular level information on the speciation and structural coordination environment of radionuclides ...

2005-07-01

133

X11 Desktop Environments (KDE and GNOME) - Part II  

CERN Document Server

X11 Desktop Environments (KDE and GNOME) - Part II

2000-01-01

134

Java-based Graphical User Interface for MAVERIC-II  

Science.gov (United States)

A computer program entitled "Marshall Aerospace Vehicle Representation in C II,

2005-01-01

135

Kapitza conductance of the (100) surface of copper  

International Nuclear Information System (INIS)

Measurements of the Kapitza conductance to liquid helium II across the (100) surface of single crystals of copper are presented. The temperature range of these measurements was 1.6-- 2.1 K. The sample surfaces were subjected to several different treatments. Some surfaces were cleaned by low-energy argon ion bombardment, annealed in an ultrahigh-vacuum system, and preserved under vacuum until purified liquid helium was admitted. Other surfaces were intentionally damaged by machining and/or exposure to the atmosphere. The conductance after these latter treatments was found to be about a factor of three higher than that of the more ideally cleaned and annealed surfaces, and a significant difference in the temperature dependence of the conductance was also observed. Conductances were reproducible for similarly treated surfaces and correlated with surface damage determined by x-ray diffraction. The relationship of these results to the numerous ...

136

Emittance of boehmite and alumina films on 6061 aluminium alloy between 295 and 773 K  

Energy Technology Data Exchange (ETDEWEB)

The total hemispherical emittance of an oxide film that formed on 6061-T6 aluminium alloy parts in the Tower Shielding Reactor-II at Oak Ridge National Laboratory was measured from 295 to 773 K using an emissometer and/or a calorimeter. The emittance of this film was critically needed for heat transfer calculations in a simulated loss-of-coolant accident of the reactor. X-ray diffraction analysis identified the film as boehmite (Al{sub 2}O{sub 3} {times} H{sub 2}O), which dehydrated to alumina (Al{sub 2}O{sub 3}) upon heating above 473 K. The measured emittances for the alumina film are in excellent agreement with published values for anodized aluminum films and for bulk alumina. Published values of the emittance of boehmite could not be found for comparison, but evidence is presented that some anodization processes for aluminum yield boehmite and not alumina films.

1991-02-01

137

Characterization of supported palladium catalysts II. Pd/SiO sub 2  

Science.gov (United States)

The isomerization of neopentane has been investigated over the 0.76 wt% Pd/SiO{sub 2} catalyst. It is found that after high temperature reduction (HTR, at 873 K) the selectivity for isomerization is much higher than that after low temperature reduction (LTR, at 573 K). A variety of experiments, including kinetic, chemisorption (O{sub 2}, H{sub 2}, and CO), temperature-programmed desorption of H{sub 2}, and X-ray diffraction, showed that this selectivity enhancement cannot be interpreted in terms of H{sub 2} retention by catalyst. Instead, the formation of Pd-Si compound(s) (most probably Pd{sub 3}Si) during HTR seems immediately responsible for the catalytic behavior of HTR Pd/SiO{sub 2} catalysts. A mechanism is proposed for the Pd-SiO{sub 2} interaction in which Pd atoms (or ions) are incorporated into the silica support (via oxygen vacancies) and a new phase of palladium silicide is formed. Regeneration by an oxygen treatment of the HTR sample does not fully ...

1989-06-01

138

Analysis of free electron laser performance utilizing the National Bureau of Standards' CW microtron  

International Nuclear Information System (INIS)

The National Bureau of Standards' (NBS) CW racetrack microtron (RTM) will be utilized as a driver for a free electron laser (FEL) oscillator. The NBS RTM possesses many exceptional properties of value for the FEL: i) CW operation, ii) energy from 20-185 MeV, iii) small energy spread and emittance, iv) excellent energy stability, and v) high average power. The 1-D FEL gain formula predicts that the FEL would oscillate at the fundamental approximately from 0.25 #mu#m to 10 #mu#m when up-grading the peak current to #>=# 2 A. In this paper, the authors present 3-D self-consistent numerical results including several realistic effects, such as emittance, betatron oscillations, diffraction and refraction. The results indicate that the design value of the transverse emittance is small enough that it does not degrade the FEL performance for intermediate to long wavelengths, and only slightly degrades the performance at the shortest wavelength under ...

139

Synthesis and characterization of nickel(II), chromium(III), cobalt(II), copper(II), zinc(II), and cadmium(II) complexes with isatin- isonicotinoylhydrazone  

International Nuclear Information System (INIS)

A few metal complexes of isatin-isonicotinoylhydrazone with Ni(II), Cr(III), Co(II), Cu(II), Zn(II) and Cd(II) have been prepared and characterized on the basis of elemental analyses, infrared and electronic spectra as well as "1H NMR spectra, conductivity and magnetic measurements. In view of the results obtained, it has been found that two molecules of isatin-isonicotinoylhydrazone are chelated to the central metal ion as bis-uninegative ONO tridentate ligand forming non-electrolytic octahedral metal complexes. (author)

1997-03-01

142

Formation of silk fibroin nanoparticles in water-miscible organic solvent and their characterization  

Energy Technology Data Exchange (ETDEWEB)

When Silk fibre derived from Bombyx mori, a native biopolymer, was dissolved in highly concentrated neutral salts such as CaCl{sub 2}, the regenerated liquid silk, a gradually degraded peptide mixture of silk fibroin, could be obtained. The silk fibroin nanoparticles were prepared rapidly from the liquid silk by using water-miscible protonic and polar aprotonic organic solvents. The nanoparticles are insoluble but well dispersed and stable in aqueous solution and are globular particles with a range of 35-125 nm in diameter by means of TEM, SEM, AFM and laser sizer. Over one half of the {epsilon}-amino groups exist around the protein nanoparticles by using a trinitrobenzenesulfonic acid (TNBS) method. Raman spectra shows the tyrosine residues on the surface of the globules are more exposed than those on native silk fibers. The crystalline polymorph and conformation transition of the silk nanoparticles from random-coil and {alpha}-helix form (Silk I) into anti-parallel {beta}-sheet form ...

2007-10-15

143

Variation of elements in self-burning coal seam from Coalspur, Alberta, Canada  

Energy Technology Data Exchange (ETDEWEB)

The elemental and mineralogical variation in a self-burning coal seam from Coalspur, Alberta, is determined using instrumental neutron activation analysis (INAA) and x-ray diffraction (XRD). The elemental variation in the coal seam is related to temperatures in the various alteration zones, i.e., oxidation, combustion, or carbonization and nature of elements. Mobilization of elements is greatest for As, Br, Cl, Mo, N, S, and Sb. Some of these elements are released to the atmosphere, as evident by the presence of orthorombic sulfur crystals on the surface or in vents at the top of the burning seam or saturation of oxidation char by volatile matter (tar). Whewellite (CaC{sub 2}O{sub 4}, H{sub 2}O) is the only Ca-bearing mineral found in the cooler area of the coal seam. Decomposition of this mineral, coupled with the presence of SO{sub 2} formed by reaction of organic sulfur with O{sub 2} in combustion, resulted in formation of a relatively high ...

1990-01-01

144

Structure and properties of a novel cobaltate La0.30CoO2  

British Library Electronic Table of Contents (United Kingdom)

The layered cobaltate La0.30CoO2 was prepared from NaxCoO2 precursor by a solid-state ionic exchange and was characterized by means of X-ray and neutron diffraction, magnetic, thermal and electric transport measurements. The compound consists of hexagonal sheets of edge-sharing CoO6 octahedra interleaved by lanthanum monolayers. Compared to Na+ in the parent system, the La3+ ions occupy only one-third of available sites, forming a 2-dimensional superstructure. The deviation from the ideal stoichiometry La1/3CoO2 introduces extra hole carriers into the diamagnetic LS Co3+ matrix making the sample Pauli paramagnetic. The temperature dependence of the electrical conductivity in La0.30CoO2 follows Mott's T?1/3 law up to about 400K, which is in contrast w...

2011-01-01

145

Structure and magnetic properties of the Al1-xGaxFeO3 family of oxides: A combined experimental and theoretical study  

International Nuclear Information System (INIS)

Magnetic properties of the Al1-xGaxFeO3 family of oxides crystallizing in a non-centrosymmetric space group have been investigated in detail along with structural aspects by employing X-ray and neutron diffraction, Moessbauer spectroscopy and other techniques. The study has revealed the occurrence of several interesting features related to unit cell parameters, site disorder and ionic size. Using first-principles density functional theory based calculations, we have attempted to understand how magnetic ordering and related properties in these oxides depend sensitively on disorder at the cation site. The origin and tendency of cations to disorder and the associated properties are traced to the local structure and ionic sizes. -- Graphical abstract: We have studied both experimentally and theoretically the important role of disorder at the cation site on magnetic and related properties of the Al1-xGaxFeO3 family of oxides crystallizing in a ...

2011-03-01

146

Structural ordering in liquid K-Te alloys  

Energy Technology Data Exchange (ETDEWEB)

Neutron diffraction from molten K{sub x}Te{sub 1{minus}x} is reported for x = 0.12 and x = 0.50 semiconducting alloys. The measured radial distribution functions (rdf) demonstrate the persistence of covalently bonded tellurium in the liquid. The rdf of the liquid K{sub 0.12}Te{sub 0.88}, which is dominated by the Te-Te contribution, is remarkably similar to that of pure liquid tellurium, the notable exception being that the nearest neighbor peak is largely resolved and found to have a coordination number slightly less than 2. The K{sub 0.50}Te{sub 0.50} rdf clearly indicates Te-Te pairing in the melt, and unexpected departure from the presumed similar Cu{sub 0.50}Te{sub 0.50}. These paired tellurium are most likely of the form (Te{sub 2}){sup 2{minus}} Zintl ions.

1994-03-01

147

Nanosized high voltage cathode material LiMg{sub 0.05}Ni{sub 0.45}Mn{sub 1.5}O{sub 4}: Structural, electrochemical and in situ investigation  

Energy Technology Data Exchange (ETDEWEB)

In this study a modified solid state synthesis (auto-ignition method) is used to form nanosized spinel type material LiMg{sub 0.05}Ni{sub 0.45}Mn{sub 1.5}O{sub 4}. This material presents a high voltage plateau at 4.75 V vs. Li/Li{sup +}. Structural and electrochemical characterisations have been performed using a wide range of techniques (TEM, neutron diffraction, galvanostatic measurements, and impedance spectroscopy). Besides, in situ XAS has been performed to monitor the evolution of Ni and Mn oxidation state during Li intercalation. The material presents an ordered cubic spinel structure, good capacity retention upon cycling (131 mAh g{sup -1} at C/10 and 117 mAh g{sup -1} at 1C) and good electronic conductivity (10{sup -6} S cm{sup -1} at RT). The simultaneous presence of Mn{sup 3+}/Mn{sup 4+} in the structure has been investigated and explained by inclusion of disordered nanodomains in the structure. (author)

2009-04-01

148

High Magnetic Field NMR Studies of LiVGe$_2$O$_6$, a quasi 1-D Spin $S = 1$ System  

CERN Document Server

We report $^{7}$Li pulsed NMR measurements in polycrystalline and single crystal samples of the quasi one-dimensional S=1 antiferromagnet LiVGe$_2$O$_6$, whose AF transition temperature is $T_{\\text{N}}\\simeq 24.5$ K. The field ($B_0$) and temperature ($T$) ranges covered were 9-44.5 T and 1.7-300 K respectively. The measurements included NMR spectra, the spin-lattice relaxation rate ($T_1^{-1}$), and the spin-phase relaxation rate ($T_2^{-1}$), often as a function of the orientation of the field relative to the crystal axes. The spectra indicate an AF magnetic structure consistent with that obtained from neutron diffraction measurements, but with the moments aligned parallel to the c-axis. The spectra also provide the $T$-dependence of the AF order parameter and show that the transition is either second order or weakly first order. Both the spectra and the $T_1^{-1}$ data show that $B_0$ has at most a small effect on the alignment of the AF ...

2001-01-01

149

Evolution of magnetic structures in the UNi{sub 2}Si{sub 2}-UPd{sub 2}Si{sub 2} system  

Energy Technology Data Exchange (ETDEWEB)

The influence of Pd-Ni substitution on the formation of magnetic phases in the tetragonal U(Ni{sub 1-x}, Pd{sub x}){sub 2}Si{sub 2} system and the concentration magnetic phase diagram are presented. A series of different substitutions was prepared and detailed studies by powder neutron diffraction were performed for x=0.25, 0.5 and 0.75. All compounds order antiferromagnetically and form ferromagnetic basal planes stacked along the c axis (q=(0,0,q{sub z}) propagation). The ground-state phase (AF3) of UNi{sub 2}Si{sub 2} is an uncompensated AF structure (++- stacking (q{sub z}=2/3)). In UPd{sub 2}Si{sub 2} the ground-state phase corresponds to the simple AF structure AF2 (+-+-(q{sub z}=1)). In solid solutions, no traces of the AF3 phase were found for x=0.25 and the ground-state powder patterns correspond to AF2 for x{>=}0.25. (orig.)

2002-07-01

150

Evolution of magnetic structures in the UNi_2Si_2-UPd_2Si_2 system  

International Nuclear Information System (INIS)

The influence of Pd-Ni substitution on the formation of magnetic phases in the tetragonal U(Ni_1_-_x, Pd_x)_2Si_2 system and the concentration magnetic phase diagram are presented. A series of different substitutions was prepared and detailed studies by powder neutron diffraction were performed for x=0.25, 0.5 and 0.75. All compounds order antiferromagnetically and form ferromagnetic basal planes stacked along the c axis (q=(0,0,q_z) propagation). The ground-state phase (AF3) of UNi_2Si_2 is an uncompensated AF structure (++- stacking (q_z=2/3)). In UPd_2Si_2 the ground-state phase corresponds to the simple AF structure AF2 (+-+-(q_z=1)). In solid solutions, no traces of the AF3 phase were found for x=0.25 and the ground-state powder patterns correspond to AF2 for x#>=#0.25. (orig.)

151

Electronic structure and nesting-driven enhancement of the RKKY interaction at the magnetic ordering propagation vector in Gd_2PdSi_3 and Tb_2PdSi_3  

International Nuclear Information System (INIS)

We present first-time measurements of the Fermi surface and low-energy electronic structure of intermetallic compounds Gd_2PdSi_3 and Tb_2PdSi_3 by means of angle-resolved photoelectron spectroscopy (ARPES). We show that the Fermi surface in both compounds consists of an electron barrel at the #GAMMA# point surrounded by spindle-shaped electron pockets originating from the same band, with the band bottom of both features lying at 0.5 eV below the Fermi level. From the experimentally measured band structure, we estimate the momentum-dependent RKKY coupling strength and demonstrate that it is peaked at the 1/2#GAMMA# K wave vector. Comparison with neutron diffraction data from the same crystals shows perfect agreement of this vector with the propagation vector of the low-temperature in-plane magnetic order, thereby demonstrating the decisive role of the Fermi surface geometry in explaining the complex magnetically ordered ground state of ternary ...

2009-03-22

152

Double umbrella structure in terbium iron garnet  

International Nuclear Information System (INIS)

The umbrella magnetic structure of the terbium iron garnet (TbIG) has been studied using neutron diffraction experiments peformed in the 4.2 to 650 K temperature range which covers both the Neel temperature (Tsub(N) = 550 +- 10 K) and the compensation temperature (Tsub(comp) = 244 +- 2 K). When T > Tsub(N), the observed peak intensities originate from nuclear contribution only. When Tsub(comp) < T < Tsub(N), the results have been interpreted in the Neel theory of ferrimagnetism. Below Tsub(comp), three salient features have been observed: there appears superstructure lines forbiden by the cubic space group Ia3d, whereas the other superstructure peaks are found absent contrary to other heavy rare earth garnets; the strongest reflexion (110) vanishes near Tsub(comp). The magnetic modes associated to the rhombohedral symmetry space group R(-3)c have been calculated; the two inequivalent magnetic sites C_1 and C'_1 of the Tb"3"+ ion have ...

1984-04-10

153

Large orbital magnetic moment and its quenching in the itinerant uranium intermetallic compounds UTGa_5 (T=Ni, Pd, Pt)  

International Nuclear Information System (INIS)

The crystal structure, lattice strain due to the antiferromagnetic ordering, and magnetic form factor in the itinerant 5f compounds UTGa_5 (T=Ni, Pd, Pt) have been studied by neutron scattering. High-resolution powder diffraction revealed that the tetragonality of the U-Ga layers increases down to the series of the transition metal element T. The integrated intensities of the antiferromagnetic reflections can be well explained with the Neel-type structure for UNiGa_5, whereas UPtGa_5 has the antiferromagnetic stacking of the ferromagnetically ordered uranium moments in the c plane. In both compounds the uranium moments orient along the c axis with moments of 0.75(5) and 0.32(5) #mu#_B for UNiGa_5 and UPtGa_5, respectively. No magnetic peak could be observed in the powder diffraction pattern of UPdGa_5 due to the small magnetic moment less than the experimental sensitivity. The orbital contributions in the magnetic form ...

2003-12-01

154

Investigation of cell parameters, microstructures and electrochemical behaviour of LiMn{sub 2}O{sub 4} normal and nano powders  

Energy Technology Data Exchange (ETDEWEB)

Nano materials are usually difficult to prepare. This work presents a simple way of preparing LiMn{sub 2}O{sub 4} nano powders using the high-energy ball milling method. This method has the advantage of producing pure, single-phase and crystalline nano powders. The milling method is carefully controlled to avoid unwanted chemical reactions that may change the stoichiometry of the material. Nano powders of between 30 and 50 nm are obtained. Structural studies of the nano powders, as well as the more conventional micron-sized LiMn{sub 2}O{sub 4}, are made using X-ray diffraction and neutron diffraction methods. Electrochemical evaluation of the materials is undertaken with a three-probe cyclic voltammetry technique and galvanostatic charge-discharge measurements. Structural studies reveal that not only are the crystallites of the nano powders much reduced in size from the normal powders, but their cell parameters are also ...

2009-03-01

155

Uranium and thorium based phosphate matrix: synthesis, characterizations and lixiviation; Matrices a base de phosphate d'uranium et de thorium: syntheses, caracterisations et lixiviation  

Energy Technology Data Exchange (ETDEWEB)

In the framework of the search for a ceramic material usable in the radioactive waste storage, uranium and thorium phosphates have been investigated. Their experimental synthesis conditions have been entirely reviewed, they lead to the preparation of four new compounds: U(UO{sub 2})(PO{sub 4}){sub 2}, U{sub 2}O(PO{sub 4}){sub 2}, UCIPO{sub 4}, 4H{sub 2}O, and Th{sub 4}(PO{sub 4}){sub 4}P{sub 2}O{sub 7}. Experimental evidenced are advanced for non existent compounds such as: U{sub 3}(PO{sub 4}){sub 4}, U{sub 2}O{sub 3}P{sub 2}O{sub 7} and Th{sub 3} (PO{sub 4}){sub 4}. Characterization by several techniques (X-rays and neutron powder diffractions, UV-Visible and Infra-red spectroscopies, XPS,...) were performed. The ab initio structure determination of U(UO{sub 2})(PO{sub 4}){sub 2} has been achieved by X-rays and refined by neutron diffractions. Through its physico-chemical analysis, we found that this ...

1995-03-01

156

Electron Diffraction Examination of Gun Barrel Coatings.  

Science.gov (United States)

... Accession Number : ADA954164. Title : Electron Diffraction Examination of Gun Barrel Coatings. Descriptive Note : Special rept.,. ...

1942-10-20

157

Pair excitation in "9"0Zr  

International Nuclear Information System (INIS)

... 3 reactions mev range 10-100 neutron spectra neutrons nuclear reaction

160

Catalytic hydration of alkynes with platinum(II) complexes  

Energy Technology Data Exchange (ETDEWEB)

Platinum(II) complexes have been investigated in the hydration of alkynes. These catalysts offer improved regioselectivity over Hg(II) counterparts. 1 fig., 2 tabs.

1993-12-17

161

Stellar (n,#gamma#) cross sections of p-process isotopes. II. "1"6"8Yb, "1"8"0W, "1"8"4Os, "1"9"0Pt, and "1"9"6Hg  

International Nuclear Information System (INIS)

The neutron-capture cross sections of "1"6"8Yb, "1"8"0W, "1"8"4Os, "1"9"0Pt, and "1"9"6Hg have been measured by means of the activation technique. The samples were irradiated in a quasistellar neutron spectrum of kT=25 keV, which was produced at the Karlsruhe 3.7-MV Van de Graaff accelerator via the "7Li(p,n)"7Be reaction. Systematic uncertainties were investigated in repeated activations with different samples and by variation of the experimental parameters, that is, irradiation times, neutron fluxes, and #gamma#-ray counting conditions. The measured data were converted into Maxwellian-averaged cross sections at kT=30 keV, yielding 1214#+-#61, 624#+-#54, 590#+-#43, 511#+-#46, and 201#+-#11 mb for "1"6"8Yb, "1"8"0W, "1"8"4Os, "1"9"0Pt, and "1"9"6Hg, respectively. The present results either represent first experimental data ("1"6"8Yb, "1"8"4Os, and "1"9"6Hg) or could be determined with significantly reduced uncertainties ...

2010-09-01

162

Magnetic excitations in R_2PdSi_3 studied by inelastic neutron scattering  

International Nuclear Information System (INIS)

R_2PdSi_3 compounds have been found to exhibit rich magnetic phenomena arising from the interplay between RKKY interaction, crystal electric field effects and geometric frustration due to the derived hexagonal AlB_2 structure. The observed crystallographic superstructure further complicates the CEF level scheme. Inelastic neutron scattering measurements on single crystals of Tm_2PdSi_3 and Er_2PdSi_3 have been performed at the cold triple axis spectrometer PANDA in FRM-II. Both compounds order antiferromagnetically at T_N=7 K and 2.1 K respectively; Er_2PdSi_3 undergoes a second phase transition at T_2=2 K. Several low lying CEF excitations (below 10 meV) were observed. The intensity of the lowest excitation show strong directional dependence (in HK0 plane for Er_2PdSi_3 and in HHL plane for Tm_2PdSi_3), from which the details of the transitional matrix could be deduced. Measurements in magnetic fields up to 13 T show Zeeman splitting of the ...

2009-03-22

166

Diffraction studies of nanocrystals: theory and experiment  

International Nuclear Information System (INIS)

Based on theoretical calculations of powder diffraction data it is shown that the assumption of the infinite crystal lattice for small particles is not justified, leads to significant changes of the diffraction patterns, and may lead to erroneous interpretation of the experimental results. An alternate evaluation of diffraction data of nanoparticles, based on the so-called 'apparent lattice parameter', alp, is proposed. (author)

2001-09-23

167

Biogenic iron oxyhydroxide formation at mid-ocean ridge hydrothermal vents: Juan de Fuca Ridge  

Energy Technology Data Exchange (ETDEWEB)

Here we examine Fe speciation within Fe-encrusted biofilms formed during 2-month seafloor incubations of sulfide mineral assemblages at the Main Endeavor Segment of the Juan de Fuca Ridge. The biofilms were distributed heterogeneously across the surface of the incubated sulfide and composed primarily of particles with a twisted stalk morphology resembling those produced by some aerobic Fe-oxidizing microorganisms. Our objectives were to determine the form of biofilm-associated Fe, and identify the sulfide minerals associated with microbial growth. We used micro-focused synchrotron-radiation X-ray fluorescence mapping (mu XRF), X-ray absorption spectroscopy (mu EXAFS), and X-ray diffraction (mu XRD) in conjunction with focused ion beam (FIB) sectioning, and highresolution transmission electron microscopy (HRTEM). The chemical and mineralogical composition of an Fe-encrusted biofilm was queried at different spatial scales, and the spatial relationship between primary ...

2008-05-22

168

MODFLOW 2.0: A program for predicting moderator flow patterns  

Energy Technology Data Exchange (ETDEWEB)

Sudden changes in the temperature of flowing liquids can result in transient buoyancy forces which strongly impact the flow hydrodynamics via flow stratification. These effects have been studied for the case of potential flow of stratified liquids to line sinks, but not for moderator flow in SRS reactors. Standard codes, such as TRAC and COMMIX, do not have the capability to capture the stratification effect, due to strong numerical diffusion which smears away the hot/cold fluid interface. A related problem with standard codes is the inability to track plumes injected into the liquid flow, again due to numerical diffusion. The combined effects of buoyant stratification and plume dispersion have been identified as being important in operation the Supplementary Safety System which injects neutron-poison ink into SRS reactors to provide safe shutdown in the event of safety rod failure. The MODFLOW code discussed here provides transient moderator flow pattern ...

1991-07-01

169

MODFLOW 2. 0: A program for predicting moderator flow patterns  

Energy Technology Data Exchange (ETDEWEB)

Sudden changes in the temperature of flowing liquids can result in transient buoyancy forces which strongly impact the flow hydrodynamics via flow stratification. These effects have been studied for the case of potential flow of stratified liquids to line sinks, but not for moderator flow in SRS reactors. Standard codes, such as TRAC and COMMIX, do not have the capability to capture the stratification effect, due to strong numerical diffusion which smears away the hot/cold fluid interface. A related problem with standard codes is the inability to track plumes injected into the liquid flow, again due to numerical diffusion. The combined effects of buoyant stratification and plume dispersion have been identified as being important in operation the Supplementary Safety System which injects neutron-poison ink into SRS reactors to provide safe shutdown in the event of safety rod failure. The MODFLOW code discussed here provides transient moderator flow pattern ...

1991-07-01

170

Irradiation behavior of FBTR mixed carbide fuel at various burn-ups  

International Nuclear Information System (INIS)

The fast breeder test reactor at Kalpakkam has completed nearly 25 years of operation and is now operating at 18 MWt capacity with 46 fuel subassemblies (FSA) in the core consisting of 27 Mark-I (70% PuC + 30% UC), 13 Mark-II (55% PuC + 45% UC) and 6 MOX (44% PuO_2 + 56% UO_2) and one test PFBR FSA. Post Irradiation Examination (PIE) campaigns on FSAs at different burnup levels has provided valuable information about the irradiation behavior of the carbide fuel. This paper gives a summary of the irradiation performance of the carbide fuel evaluated through some of the investigations such as neutron radiography, x-radiography, gamma scanning, fission gas analysis and ceramography. Burnup of the carbide fuel could be enhanced from the initial design burnup limit of 50 GWd/t to 165 GWd/through systematic PIE. (author)

2010-10-01

171

Application of variational methods to fusion reactor blanket studies  

International Nuclear Information System (INIS)

The general development of variational methods for fusion reactor blanket studies is given. Important quantities such as tritium breeding ratio and total nuclear heating are linear functionals of the solutions to the Boltzmann transport equation. To estimate a neutronic quantity by variational methods is, in general, to carry out the scalar product formulation of the Roussopoulos variational principle, or the Schwinger variational principle, with the help of the associated adjoint transport equation where the appropriate response function for the estimate is taken as the source. A multipoint interpolation method based on the above variational principles has been developed and compared to other variational approaches. The method of variational interpolation removes the need to compute both forward and adjoint solutions while the error has the characteristic of cancellation of errors between interpolation reference points. Finally, the practical computational ...

172

(Phospinoalkyl)silyl complexes. 10. Formation of chelated bis[(diphenylphosphinoethyl)diorganosilyl]platinum(II) complexes. Precoordination through phosphorus, intermediacy of a platinum(IV) disilyl, and diastereoisomerism at planar platinum(II) in 'chelate-assisted' hydrosilylation  

Energy Technology Data Exchange (ETDEWEB)

Addition of the silane PPh[sub 2]CH[sub 2]CH[sub 2]SiMe[sub 2]H (chelH, 1a) to Pt(COD)[sub 2] (COD = cycloocta-1,5-diene) affords in high yield the cis-bis chelate Pt(chel)[sub 2] (2); formation of the same product from Pt(COD)(X)Y (X = Y = Me; X = Me, Y = Cl) has been shown by NMR spectroscopy ([sup 1]H, [sup 31]P, [sup 195]Pt) to proceed via prior coordination of chelH through P to afford Pt(chelH)[sub 2](X)(Y) (cis and trans isomers) and through intermediacy of PtH(chel)[sub 2]Cl (22) in which P trans to Si at Pt(IV) leads to an exceptionally low [sup 2]J(Pt-P) = 1084 Hz. Cleavage of Pt-Si bonds in 2 by HCl can be controlled to give the monochelate species Pt(chel)(chelH)Cl (7), from which chelH is displaced by PMe[sub 2]Ph, or trans-PtH(PPh[sub 2]CH[sub 2]SiMe[sub 2]Cl)[sub 2]Cl (9). Products related to 9 result from Pt-Si bond cleavage by I[sub 2] or MeI. Using the analogue PPh[sub 2]CH[sub 2]CH[sub 2]SiMe(Ph)H (1c) of 1a, the analogue Pt-[PPh[sub 2]CH[sub 2]CH[sub 2]SiMe(Ph)][sub ...

1991-08-21

178

A summary of neutron radiography and neutron radioscopy applications at the University of Michigan Phoenix Memorial Laboratory  

International Nuclear Information System (INIS)

Neutron radiography and neutron radioscopy are rapidly becoming the valuable tools for nondestructive testing and basic research. The Phoenix Memorial Laboratory has developed a neutron facility capable of both film neutron radiography and real time neutron radioscopy, and has used this facility to study several phenomena of interest to the researchers in many areas. Neutrons can be used for imaging the phenomena that X-ray cannot image, such as the presence, absence or movement of hydrogenous materials inside metals such as aluminum or steel. There are three basic methods for obtaining images using neutrons: high resolution film neutron radiography, real-time neutron radioscopy and transfer film neutron radiography. The neutron radiography facility at ...

1992-03-01

180

Improvement of numerical analysis method for FBR core characteristics. 2  

Energy Technology Data Exchange (ETDEWEB)

This report is composed of the following two parts and appendix. (I) Improvement of the Method for Evaluating Reactivity Based on Monte Carlo Perturbation Theory: Theoretical formulation in Monte Carlo perturbation method had been checked, and then introduced into a calculation code. There are some cases that the results of the change of eigenvalues becomes positive or negative by changing the estimator, and there is no reasonable difference in the results between the conventional method, which does not consider the change of neutron source distribution caused by a perturbation, and the new method, which consider that change. Thus it is still necessary to check the Monte Carlo perturbation code. (II) Improvement of Nodal Transport Method for 3-D Hexagonal Geometry: We can accurately evaluate hexagonal geometry FBR core by nodal transport calculation code for hexagonal-Z geometry named `NSHEX`. However it is also found that in very heterogeneous ...

1997-03-01

181

A final report for: Gallium arsenide P-I-N detectors for high-sensitivity imaging of thermal neutrons  

Energy Technology Data Exchange (ETDEWEB)

This SBIR Phase I developed neutron detectors made from gallium arsenide (GaAs) p-type/ intrinsic/n-type (P-I-N) diodes grown by metalorganic chemical vapor deposition (MOCVD) onto semi-insulating (S1) bulk GaAs wafers. A layer of isotonically enriched boron-10 evaporated onto the front surface serves to convert incoming neutrons into lithium ions and a 1.47 MeV alpha particle which creates electron-hole pairs that are detected by the GaAs diode. Various thicknesses of ''intrinsic'' (I) undoped GaAs were tested, as was use of a back-surface field (BSF) formed from a layer of Al{sub x}Ga{sub 1-x}As. Schottky-barrier diodes formed from the same structures without the p+ GaAs top layer were tested as a comparison. After mesa etching and application of contacts, devices were tested in visible light before application of the boron coating. Internal quantum efficiency (IQE) of the best diode near the GaAs bandedge ...

1999-04-01

182

Development of the high sensitivity real-time neutron radiography for low-flux neutron sources  

Energy Technology Data Exchange (ETDEWEB)

The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was ...

1994-08-01

183

Development of the high sensitivity real-time neutron radiography for low-flux neutron sources  

International Nuclear Information System (INIS)

The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was ...

1994-01-01

184

Neutron escape from isobaric analogue resonances  

International Nuclear Information System (INIS)

... level widths mev range 01-10 neutrons nuclear reactions proton beams

185

JENDL-4.0: A database on neutron-induced reactions for nuclear science and engineering  

International Nuclear Information System (INIS)

... compilation fission products j codes mixed oxide fuels neutron reactions

2010-12-01

186

Using neutron-activation detectors with fissionable nuclides  

Energy Technology Data Exchange (ETDEWEB)

Presented are results of a test of a method for measuring neutron fluences using detectors with fissionable nuclides. The investigations show the soundness of of using neutron-activation detectors of the type Am for mesurements in nuclear installations for values of thermal-neutron fluence of from 10/sup 13/ to 10/sup 20/ neutrons/cm/sup 2/ with exposure for up to several months. The proposed method can be used for prolonged measurements in strong fields of both thermal and fast neutrons.

1986-09-01

187

Neutron scattering studies in the actinide region. Progress report, August 1, 1992--July 31, 1993  

Energy Technology Data Exchange (ETDEWEB)

This report discusses the following topics: Prompt fission neutron energy spectra for {sup 235}U and {sup 239}Pu; Two-parameter measurement of nuclear lifetimes; ``Black`` neutron detector; Data reduction techniques for neutron scattering experiments; Inelastic neutron scattering studies in {sup 197}Au; Elastic and inelastic scattering studies in {sup 239}Pu; and neutron induced defects in silicon dioxide MOS structures.

1993-09-01

188

Measurement of the fast neutron component in the beam of the NPL Thermal Neutron Column using a Bonner sphere spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)

1999-05-01

189

Measurement of the fast neutron component in the beam of the NPL Thermal Neutron Column using a Bonner sphere spectrometer  

International Nuclear Information System (INIS)

Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)

190

Synthesis, characterization and biological evaluation of mononuclear Co(II), Ni(II), Cu(II) and Pd(II) complexes with new N2O2 Schiff base ligands.  

Science.gov (United States)

New tetradentate N(2)O(2) donor Schiff bases and their mononuclear Co(II), Ni(II), Cu(II), and Pd(II) complexes were synthesized and characterized extensively by IR, (1)H-, (13)C-NMR, mass, ESR, conductivity measurements, elemental and thermal analysis. Specifically the magnetic and electronic spectral measurements demonstrate the octahedral structures of cobalt(II), nickel(II) complexes and square planar geometries of copper(II), palladium(II) complexes. All the ligands and complexes were screened for their in vitro antibacterial activity against two gram-positive bacteria (Bacillus subtilis, Staphylococcus aureus) and two gram-negative bacteria (Escherichia coli, Klebsiella pneumonia). In this study, Pd(II) complexes exhibited potent antibacterial activity against B. subtilis, S. aureus whereas ...

2011-02-01

191

Magnetic and transport properties of Ba_2Co_9O_1_4 and Ba_1_._9A_0_._1Co_9O_1_4 (A=La or Na)  

International Nuclear Information System (INIS)

The valence and spin-state distributions of Co ions and the complex structure of antiferromagnetic Ba_2Co_9O_1_4 have led to the suggestion that doped Ba_2Co_9O_1_4 compounds may be good thermoelectric materials. We have checked this suggestion by measuring the magnetic properties as well as the transport properties of nominal Ba_1_._9A_0_._1Co_9O_1_4 (A=La or Na). We show that although all compounds are indicated to be single phase by powder X-ray diffraction analysis, they are all p-type polaronic conductors with low mobile-hole concentrations. Magnetic-susceptibility data of the parent and La-doped compounds give evidence of a second magnetic phase with ferromagnetic order setting in below 215 K; but this second phase is not seen in the Na-doped sample. We conclude that the structure is stabilized by oxidation and that cation exolution from the Ba_2Co_9O_1_4 structure creates cation vacancies that oxidize the high-spin (HS) Co(II) to the ...

2010-11-01

192

Synthesis, Characterization and Biological Properties of Anions of Bivalent Transition Metal [Co(II) and Ni(II)] Complexes With Acylhydrazine Derived ONO Donor Schiff Bases  

UK PubMed Central (United Kingdom)

Some acylhydrazine derived ONO donor Schiff bases and their Co(II) and Ni(II) complexes have been prepared having the same metal ion (cation) but different anions. These synthesized metal(II)...Full Text Available

2000-01-01

193

Beam-induced damage on diffractive hard X-ray optics  

UK PubMed Central (United Kingdom)

The issue of beam-induced damage on diffractive hard X-ray optics is addressed. For this purpose a systematic study on the radiation damage induced by a high-power X-ray beam is carried out in both...Full Text Available

2010-11-01

194

Neutron imaging system for neutron tomography, radiography, and beam diagnostics  

Energy Technology Data Exchange (ETDEWEB)

A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.

1995-12-31

195

New materials synthesis: characterization of some metal-doped antimony oxides  

Energy Technology Data Exchange (ETDEWEB)

In order to understand the chemistry of altermetal dopants in antimony oxide, the detailed structural characterization of two ..beta..-Sb/sub 2/O/sub 4/ compounds is reported, Mo-doped ..beta..-Sb/sub 2/O/sub 4/ (1.5 metal%) and V-doped ..beta..-Sb/sub 2/O/sub 4/ (5 metal%). The methods used to characterize these materials are X-ray and neutron diffraction, scanning electron microscopy, Mo K-edge extended X-ray absorption fine structure spectroscopy, and elemental analysis. The atomic position of each of these dopants in Sb/sub 2/O/sub 4/ is radically different as is the overall effect on the host structure. Molybdenum does not substitute for Sb atoms, rather the Mo atoms are found in channels of electron density formed by Sb/sup 3 +/ lone pairs. The two nearest Sb/sup 3 +/ are absent and the oxygen stoichiometry is preserved. The formula is Sb/sub 1.97/Mo/sub 0.015/O/sub 4/. Vanadium incorporates substitutionally for the Sb/sup 3 +/ atoms and ...

1986-10-01

196

In situ texture analysis under applied load  

International Nuclear Information System (INIS)

The in-situ measurement of a crystallographic texture is a special type of a non-destructive measurement, which need special equipments. Due to the high photon flux and the excellent brilliance high energetic synchrotron radiations are a fantastic tool particular in fast experimentation. Moreover, a high penetration power allows the investigation of standard tensile sample of the DIN-norm. A loading device with a power up to 20 kN was installed at the hard wiggler beamline BW5 (HASYLAB-DESY) to perform in-situ strain and in-situ texture analysis. Using 100keV X-rays one gets short wavelength so that a 2D image-plate detector offers a wide range of diffraction pattern within the first 10 degree in 2 theta. Thermal neutron is another radiation with a high penetration power, which is the standard method for global texture analysis of bulk samples. As an example rectangular extruded Mg- Az31 was investigated by an in-situ. tensile experiment. ...

197

Crystal-field analysis of Eu"3"+ energy levels in the new rare-earth R BiY_1_-_xR_xGeO_5 oxide  

International Nuclear Information System (INIS)

Pale colored BiY_1_-_xR_xGeO_5 (R=rare-earth from Pr to Yb) polycrystalline samples exhibit a crystalline phase isostructural with the orthorhombic Pbca (No. 61) structure-type established for BiYGeO_5 and BiYbGeO_5. R occupies a single point site in the host, with the lowest C_1 symmetry. While for Pr and Nd x must be #<=#0.35, for smaller R ions, Sm to Yb, the phase appears for any x content. Detailed crystallographic data for BiErGeO_5 have been determined from the structure refinement of its neutron diffraction profile at room temperature. Optical absorption and photoluminescence measurements at 10 K have been performed for BiEuGeO_5. An initial approach to the parametrization of crystal-field effects on this new host has been provided by results of the semi-empirical Simple Overlap Model, which considers the crystallographic positions of the nearest neighbors around R. Furthermore, the strongly reduced "7F_J_M set of levels of the 4f"6 ...

2002-07-13

198

RNA polymerase II trigger loop residues stabilize and position the incoming nucleotide triphosphate in transcription  

UK PubMed Central (United Kingdom)

A structurally conserved element, the trigger loop, has been suggested to play a key role in substrate selection and catalysis of RNA polymerase II (pol II) transcription elongation. Recently resolved...Full Text Available

2010-09-07

199

PDP-1 Links the TGF-? and IIS Pathways to Regulate Longevity, Development, and Metabolism  

UK PubMed Central (United Kingdom)

The insulin/IGF-1 signaling (IIS) pathway is a conserved regulator of longevity, development, and metabolism. In Caenorhabditis elegans IIS involves activation of DAF-2 (insulin/IGF-1...Full Text Available

2011-04-01

200

Genetic heterogeneity in human T-cell leukemia/lymphoma virus type II.  

UK PubMed Central (United Kingdom)

DNA from the peripheral blood mononuclear cells of 17 different individuals infected with human T-cell lymphoma/leukemia virus type II (HTLV-II) was successfully amplified by the polymerase chain reaction...Full Text Available

1993-03-01

201

Structure analysis of ferrite in deformed pearlitic steel by means of X-ray diffraction method with synchrotron radiation  

Energy Technology Data Exchange (ETDEWEB)

Structure of ferrite in drawn pearlitic steel containing 0.9 mass% C was investigated with X-ray diffraction technique using synchrotron radiation. In the detailed analysis of diffraction peaks of ferrite during the drawing process, it was experimentally revealed that the transformation of ferrite from bcc to bct due to the supersaturation of carbon in ferrite of heavily drawn pearlitic steel.

2004-07-15

202

Structure analysis of ferrite in deformed pearlitic steel by means of X-ray diffraction method with synchrotron radiation  

International Nuclear Information System (INIS)

Structure of ferrite in drawn pearlitic steel containing 0.9 mass% C was investigated with X-ray diffraction technique using synchrotron radiation. In the detailed analysis of diffraction peaks of ferrite during the drawing process, it was experimentally revealed that the transformation of ferrite from bcc to bct due to the supersaturation of carbon in ferrite of heavily drawn pearlitic steel.

2004-07-01

203

Reflective diffraction grating  

Energy Technology Data Exchange (ETDEWEB)

Reflective diffraction grating. A focused ion beam (FIB) micromilling apparatus is used to store color images in a durable medium by milling away portions of the surface of the medium to produce a reflective diffraction grating with blazed pits. The images are retrieved by exposing the surface of the grating to polychromatic light from a particular incident bearing and observing the light reflected by the surface from specified reception bearing.

2003-06-24

204

Null field method in wave diffraction problems  

British Library Electronic Table of Contents (United Kingdom)

Diffraction by an impermeable scatterer in ?3 with a Dirichlet boundary condition is considered. It is shown that the null field equation is equivalent to the original diffraction problem. The general theoretical constructions are illustrated by analyzing the excitation of a sphere by a point source. The evolution of the residual of the null field equation as the scatterer surface is approached by an auxiliary surface is estimated.

2011-01-01

205

Conceptual design of a nuclear reactor facility for medical and biological purposes  

Energy Technology Data Exchange (ETDEWEB)

Optimal neutron energy for boron neutron capture therapy (BNCT) has been studied. Epithermal neutron is superior to thermal neutrons in treating deep-seated tumors. Design of the epithermal neutron column for BNCT has been performed by using a two-dimensional transport calculation code. Aluminum and heavy water are used as moderation materials. A thermal neutron column is also designed using heavy water as thermalization material. The configuration of the facility for treatment and research of BNCT and also for basic radio-biological studies of neutrons has been presented.

1981-09-01

206

Conceptual design of a nuclear reactor facility for medical and biological purposes  

International Nuclear Information System (INIS)

Optimal neutron energy for boron neutron capture therapy (BNCT) has been studied. Epithermal neutron is superior to thermal neutrons in treating deep-seated tumors. Design of the epithermal neutron column for BNCT has been performed by using a two-dimensional transport calculation code. Aluminum and heavy water are used as moderation materials. A thermal neutron column is also designed using heavy water as thermalization material. The configuration of the facility for treatment and research of BNCT and also for basic radio-biological studies of neutrons has been presented. (author).

207

Type II Quantum Computing With Superconductors.  

Science.gov (United States)

The results of this research centered on the experimental studies of a single superconducting persistent current qubit, the implementation of type-II algorithms using these qubits, and the proposal for adiabatic quantum computing using these qubits. The m...

2004-01-01

209

Stress Tolerance of Photosystem II in Vivo  

UK PubMed Central (United Kingdom)

The in vivo photochemical activity of photosystem II was inferred from modulated chlorophyll fluorescence and photoacoustic measurements in intact leaves of several plant species (Lycopersicon...Full Text Available

1992-09-01

210

Radiation Damage Calculations for the FUBR and BEATRIX Irradiations of Lithium Compounds in EBR-II and FFTF  

Energy Technology Data Exchange (ETDEWEB)

Radiation Damage Calculations for the FUBR and BEATRIX Irradiations of Lithium Compunds in EBR-II and FFTF

1999-05-01

211

REDUCTION OF INORGANIC COMPOUNDS WITH MOLECULAR HYDROGEN BY MICROCOCCUS LACTILYTICUS II.  

UK PubMed Central (United Kingdom)

Woolfolk, C. A. (University of Washington, Seattle). Reduction of inorganic compounds with molecular hydrogen by Micrococcus lactilyticus. II. Stoichiometry with inorganic...Full Text Available

1962-10-01

212

Quantitative Spectroscopy of Photospheric-Phase Type II SN  

Science.gov (United States)

... and high-quality photospheric-phase Type II SN spectra to constrain core- collapse SN explosions, massive star evolution, and distances in the Universe ...

213

LLNL Compliance Plan for TRUPACT-2 Authorized Methods for Payload Control  

Energy Technology Data Exchange (ETDEWEB)

This document describes payload control at LLNL to ensure that all shipments of CH-TRU waste in the TRUPACT-II (Transuranic Package Transporter-II) meet the requirements of the TRUPACT-II SARP (safety report for packaging). This document also provides specific instructions for the selection of authorized payloads once individual payload containers are qualified for transport. The physical assembly of the qualified payload and operating procedures for the use of the TRUPACT-II, including loading and unloading operations, are described in HWM Procedure No. 204, based on the information in the TRUPACT-II SARP. The LLNL TRAMPAC, along with the TRUPACT-II operating procedures contained in HWM Procedure No. 204, meet the documentation needs for the use of the TRUPACT-II at LLNL. Table 14-1 provides a summary of the LLNL waste generation and ...

1995-03-01

214

Gravity Gradiometer Survey and Real Time Techniques for ...  

Science.gov (United States)

... 4 II. INERTIAL NAVIGATION ERROR EQUATIONS ..... 5 ... 4- Page 20. Chapter II INERTIAL NAVIGATION ERROR EQUATIONS ...

1981-12-01

215

Cd(II), Pb(II) and Zn(II) removal from contaminated water by biosorption using activated sludge biomass  

Energy Technology Data Exchange (ETDEWEB)

Biosorption using activated sludge biomass (ASB) as a potentially sustainable technology for the treatment of wastewater containing different metal ions (Cd(II), Pb(II) and Zn(II)) was investigated. ASB metal uptake clearly competed with protons consumed by microbial biomass compared with control tests with non-activated sludge biomass. Biosorption tests confirmed maximum exchange between metal ions and protons at pH 2.0-4.5. It was revealed by the study that the amount of metal ions released from the biomass increased with biomass sludge concentration. The result showed that maximum absorption of metal ions was observed for Cd(II) at pH 3.5, Pb(II) at pH 4.0, and pH 4.5 for Zn(II) ions. The maximum absorption capacities of ASB for Cd(II), Pb(II) and Zn(II) were determined to be 59.3, 68.5 and 86.5%, ...

2010-02-15

217

Measurement and analysis of neutron-induced soft errors in sub-half-micron CMOS circuits  

Energy Technology Data Exchange (ETDEWEB)

Neutron-induced soft error rates (SER`s) of subhalf-micron CMOS SRAM and Latch circuits were studied both experimentally and analytically to investigate cosmic ray neutron-induced soft errors (SE`s). Because the neutron beam used in the measurement has an energy spectrum similar to that of sea-level atmospheric neutrons, the SER data corresponds to those induced by cosmic ray neutrons. The {alpha}-particle induced SER`s were also measured for comparison with the neutron-induced SER`s. Neutron-induced SE`s occurred in both circuits. On the other hand, {alpha}-induced SE`s occurred in SRAM, but not in the Latch circuit. The measured SER`s agreed with simulated results. The authors discussed the significance of how cosmic ray neutrons affects CMOS circuits at ground level.

1998-07-01

218

Comparison on the growth of oxide films formed in alloy 800 and alloy 600 in an aqueous medium at high temperature  

International Nuclear Information System (INIS)

Alloy 800 and Alloy 600 are well known for their resistance to corrosion in an aqueous medium at high pressure and temperature, for which they have been widely used for more than 3 decades in different structural components of water refrigerated nuclear reactors, especially as material for the steam generator tubes (SG) in these nuclear plants. The SG tubes in the Atucha I and Embalse Nuclear Plants are made with Alloy 800. The speed of corrosion of these materials in a reactor's refrigerant medium, while very small is perfectly measurable and can be described by parabolic or logarithmic type kinetics. In other words this speed is high in the first states of growth during the formation of a protective oxide film but then drops to almost stationary values. One characteristic of these films is the formation of a double layer (or duplex): i) an internal adhering layer, of approximately constant thickness, formed by small microcrystals (#<=#0.05 mm), ii) a less ...

2006-12-01

219

Verification of lithium detector efficiency using DD neutron  

International Nuclear Information System (INIS)

The detection efficiency of a lithium glass detector was calculated using MCNP code, and the calculation was compared with the published results in Pulsed Sphere Plan. A lithium glass detector of our own was made, and its neutron efficiency was calculated. The calculated neutron efficiency was verified with both pulsed and steady DD neutrons. Characteristics of Neutron response of "6Li detector was discussed. (authors)

2005-08-01

220

Neutron irradiation effects on plasma facing materials  

Energy Technology Data Exchange (ETDEWEB)

This paper reviews the effects of neutron irradiation on thermal and mechanical properties and bulk tritium retention of armour materials (beryllium, tungsten and carbon). For each material, the main properties affected by neutron irradiation are described and the specific tests of neutron irradiated armour materials under thermal shock and disruption conditions are summarized. Based on current knowledge, the expected thermal and structural performance of neutron irradiated armour materials in the ITER plasma facing components are analysed.

2000-12-01

221

Monte Carlo design calculations for a neutron imaging facility collimator  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for computed tomography and real-time neutron radiography is being developed at the University of Texas at Austin. The TRIGA reactor is a graphite-reflected Mark It pool-type research reactor. The neutron imaging facility will use beam port, which is at one end of a through part. Monte Carlo calculations were used to design the neutron collimator for this facility.

1996-12-31

222

Albedo method applied to coupled neutron-gamma shielding radiations; Metodo do Albedo aplicado a blindagem de radiacoes neutron-gama acoplados  

Energy Technology Data Exchange (ETDEWEB)

The Albedo Theory was applied in order to develop an one-group algorithm for coupled neutron-gamma shielding calculations. The configuration analyzed consists of multilayered plane systems, where a incident neutron current generates gamma radiation through neutron-gamma reactions. The results obtained by Albedo Method and ANISN code have shown excellent agreement. (author)

2000-07-01

223

Operation experience with the 3 MW TRIGA Mark-II research reactor of Bangladesh  

International Nuclear Information System (INIS)

The 3 MW TRIGA Mark-II research reactor of Bangladesh Atomic Energy Commission (BAEC) has been operating since September 14, 1986. The reactor is used for radioisotope production ("1"3"1I, "9"9"mTc, "4"6Sc), various R and D activities and manpower training. The reactor has been operated successfully since it's commissioning with the exception of a few reportable incidents. Of these, the decay tank leakage incident of 1997 is considered to be the most significant one. As a result of this incident, reactor operation at full power under forced-convection mode remained suspended for about 4 years. During that time, the reactor was operated at a power level of 250 kW so as to carry out experiments that require lower neutron flux. This was made possible by establishing a temporary by pass connection across the decay tank using local technology. The other incident was the contamination of the Dry Central Thimble (DCT) that took place in March 2002 ...

2004-09-15

228

Start II, red ink, and Boris Yeltsin  

Energy Technology Data Exchange (ETDEWEB)

Apart from the vulnerability implied by the START II treaty, it will bear the burden of the general political opposition to the Yeltsin administration. START II will be seen as part of an overall Yeltsin-Andrei Kozyrev foreign policy that is under fire for selling out Russian national interests in Yugoslavia, the Persian Gulf, and elsewhere. This article discusses public opinion concerning START II, the cost of its implementation, and the general purpose of the treaty.

1993-04-01

229

Picture tour of Sasol II coal liquefaction plant  

Energy Technology Data Exchange (ETDEWEB)

This is a collection of photographs of the plant which is now almost completed.

1980-03-01

230

Performance of CDF calorimeter simulation for Tevatron Run II  

Energy Technology Data Exchange (ETDEWEB)

The upgraded CDF II detector has collected first data during the initial operation of the Tevatron accelerator in Run II. The simulation of the CDF electromagnetic and hadronic central and upgraded plug (forward) calorimeter is based on the Gflash calorimeter parameterization package used within the GEANT based detector simulation of the Run II CDF detector. We present the results of tuning the central and plug calorimeter response to test beam data.

2002-09-19

231

PRESTO-PREP: a data preprocessor for the PRESTO-II code  

Energy Technology Data Exchange (ETDEWEB)

PRESTO-II is a computer code developed to evaluate possible health effects from shallow land disposal of low level radioactive wastes. PRESTO-PREP is a data preprocessor that has been developed to expedite the formation of input data sets for PRESTO-II. PRESTO-PREP utilizes a library of nuclide and risk-specific data. Given an initial waste inventory, the code creates the radionuclide portion of the associated input data set for PRESTO-II. 2 references.

1984-07-01

234

Embedded computer systems for control applications in EBR-II  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to describe the embedded computer systems approach taken at Experimental Breeder Reactor II (EBR-II) for non-safety related systems. The hardware and software structures for typical embedded systems are presented The embedded systems development process is described. Three examples are given which illustrate typical embedded computer applications in EBR-II.

1993-01-01

239

Angiotensin-II-induced apoptosis requires regulation of nucleolin and Bcl-xL by SHP-2 in primary lung endothelial cells  

UK PubMed Central (United Kingdom)

Angiotensin II (Ang II) is a key proapoptotic factor in fibrotic tissue diseases. However, the mechanism of Ang-II-induced cell death in endothelial cells has not been previously elucidated....Full Text Available

2010-05-15

240

Studies of neutron dosimetry  

Energy Technology Data Exchange (ETDEWEB)

A high-purity, intense, fast-neutron source has been developed at our laboratory. We describe two inexpensive, straightforward methods of determining the total number of neutrons produced and we review precautions to be taken in applying these methods. (orig.).

1997-04-01

241

Research on Dynamic Neutron Radiography in HANARO  

Energy Technology Data Exchange (ETDEWEB)

Neutron radiography is a non-destructive test method to examine a material by using the dependency of neutron attenuation on the nuclear characteristics of the atoms composing the object material. There are two categories of neutron radiography; static neutron radiography and dynamic neutron radiography. The static neutron radiography is a technique to observe a standing object by using a camera or a film cassette. The dynamic neutron radiography(DNR) is a technique to observe a moving object usually by using a camera. Depending on the camera frame rate, the dynamic neutron radiography is categorized into the real time neutron radiography(RTNR) and the high speed neutron radiography(HSNR). The frame rate for RTNR is 30 frames/s and that for HSNR is usually more that 500 ...

2005-07-01

242

Research on Dynamic Neutron Radiography in HANARO  

International Nuclear Information System (INIS)

Neutron radiography is a non-destructive test method to examine a material by using the dependency of neutron attenuation on the nuclear characteristics of the atoms composing the object material. There are two categories of neutron radiography; static neutron radiography and dynamic neutron radiography. The static neutron radiography is a technique to observe a standing object by using a camera or a film cassette. The dynamic neutron radiography(DNR) is a technique to observe a moving object usually by using a camera. Depending on the camera frame rate, the dynamic neutron radiography is categorized into the real time neutron radiography(RTNR) and the high speed neutron radiography(HSNR). The frame rate for RTNR is 30 frames/s and that for HSNR is usually more that 500 ...

2005-10-27

243

On the temperature dependence of the level density parameter and its effect upon neutron evaporation spectra  

Energy Technology Data Exchange (ETDEWEB)

Effects associated with the temperature dependence of the level density parameter, a(T), are investigated in connection with neutron evaporation processes. Different approximations, for this temperature dependence, are compared for the case of neutron emission from the compound nucleus /sup 209/Pb.

1987-07-01

244

Neutron star collisions and the r-process  

Energy Technology Data Exchange (ETDEWEB)

It is shown that a natural consequence of the binary pulsar's evolution is a neutron star collision. Such a collision is expected to eject neutron-rich matter of an r-process character. Taking reasonable estimates for the number of such events over the history of the galaxy, it may be that they account for all of the r-process nuclei.

1982-01-01

245

Emission of {sup 14}C by the Almirante Alvaro Alberto Nuclear Power Plant 1 and 2 and their local effects on the environmental levels; Emissao de {sup 14}C pelas unidades 1 e 2 da Central Nuclear Almirante Alvaro Alberto (CNAAA) e seu efeito local nos niveis ambientais  

Energy Technology Data Exchange (ETDEWEB)

{sup 14}C is a is a long-lived beta-emitting nuclide (T{sub 1/2} = 5730 years) produced naturally in the upper atmosphere as a result of reactions between neutrons and stable {sup 14}N({sup 14}N(n,p){sup 14}C). Although in a lesser extent, nuclear power plants produce {sup 14}C as well during their routine operation. Since it is converted in {sup 14}CO{sub 2} and mixed throughout the atmosphere, it is incorporated into plant tissues, via photosynthesis process, and hence in food chain. Because of the biological importance of {sup 14}C and long half-life, it is of interest to quantify the amounts released by nuclear industry. The Brazilian nuclear central named Nuclear Central Admiral Alvaro Alberto (CNAAA) has two nuclear reactors of PWR type in operation, Angra I (657 MWe) and Angra II (1350 MWe), and one under construction, Angra III (1309 MWe PWR). The aim of this study was to determine the strength of the sources and the {sup 14}C content ...

2006-07-01

246

Hydration of swelling clay and bacteria interaction. An experimental in situ reaction study; Hydratation des argiles gonflantes et influence des bacteries. Etude experimentale de reaction in situ  

Energy Technology Data Exchange (ETDEWEB)

This study reports on the physical-chemical behaviour of swelling di-octahedral clays (smectites) and their interaction with aqueous solutions and bacteria (Shewanella putrefaciens). Experimental results are presented for compacted clays, hydrated under confined volume conditions, using a new type of reaction-cell (the 'wet-cell' of Warr and Hoffman, 2004) that was designed for in situ X-ray diffraction (XRD) measurement. For comparison, dispersed clay systems were studied using standard batch solutions subjected to varying degrees of agitation. The combination of time-dependent in situ XRD measurements with gravimetric measurements and calculated diffraction patterns using the CALCMIX software (Plancon and Drits, 1999) allowed to successful quantification of the dynamics of water uptake and storage. This analytical procedure combined with published water vapour adsorption data enabled determination of the abundance of ...

2008-01-15

247

Studies of a Poenitz-type black neutron detector as a neutron flux monitor  

Energy Technology Data Exchange (ETDEWEB)

A black neutron detector of novel design has been constructed and tested as a neutron flux monitor. The neutron time-of-flight (TOF) technique was used to measure the zero degree neutron spectrum from a subnanosecond pulsed proton beam on a thick metallic lithium target. We describe the detector, discuss the shielding arrangement and electronics, determine the low-energy cut-off. We calculate the efficiency, show spectra and compare measured zero degree differential cross-section of the {sup 7}Li(p, n{sub 0}){sup 7}Be reaction with recommended published cross-sections. (orig.).

1997-04-01

248

Phenomenological dirac optical potential for neutron cross sections  

International Nuclear Information System (INIS)

Because of limitation on neutron-incident data, it is difficult to obtain global optical model potential for neutrons. In contrast, there are some global optical model potentials for proton in detail. It is interesting to convert the proton-incident global optical potentials into neutron-incident ones. In this study we introduce (N-Z)/A dependent symmetry potential terms into the global proton-incident optical potentials, and then obtain neutron-incident ones. The neutron potentials reproduce total cross sections in an acceptable degree. However, a comparison with potentials proposed by other authors brings about a confused situation in the sign of the symmetry terms. (author).

1997-03-01

249

Nuclear borehole logging using lithium detector assemblies  

International Nuclear Information System (INIS)

A method and apparatus for nuclear borehole logging, and in particular, neutron porosity logging, uses a neutron source, and a pair of spaced lithium detectors, preferably Li"6I crystal or Li"6 doped glass, to detect neutrons emitted from a borehole formation being logged. The spectrum developed by the lithium detectors is processed to remove the gamma ray background radiation and the hydrogen absorption peak, thus allowing a more accurate neutron count. A Gaussian curve is fitted to the neutron peak of the spectrum, the curve eliminating the hydrogen absorption peak. The area under this Gaussian curve represents the neutron count. (author).

1991-11-01

250

Introduction to neutron scattering for materials science  

International Nuclear Information System (INIS)

The introduction prior to series of papers on the application of neutrons for materials science (MS) in this issue starts with a brief summary of neutron scattering research history in Japan; from the individual activity by Motoharu Kimura at RIKEN early around 1940s to those at present era of world leading neutron science facilities of both JRR3 research reactor and JPARC of the largest proton Accelerator complex in Tokai. Then physical properties of low energy neutrons applied to MS as well as such neutron sources are also reviewed (http://www.jstage.jst.go.jp/browse/jvsj2). (author)

2010-12-01

251

Determination of fast neutron flux distribution in irradiation sites of the Malaysian Nuclear Agency research reactor  

British Library Electronic Table of Contents (United Kingdom)

Determination of thermal to fast neutron flux ratio (ffast) and fast neutron flux (phi-fast) is required for fast neutron reactions, fast neutron activation analysis, and for correcting interference reactions. The ffast and subsequently phi-fast were determined using the absolute method. The ffast ranged from 48 to 155, and the phi-fast was found in the range 1.03x1010-4.89x1010 n cm-2 s-1. These values indicate an acceptable conformity and applicable for installation of the fast neutron facility at the MNA research reactor.

2011-01-01

252

Detection of mice lung cancer by neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Thermal neutron beam from the TNRF of JRR-3M was utilized for detection of mice lung cancer in vivo. Both the static and real-time neutron imaging were tried. Very strong thermal neutron beam is necessary to detect lung cancers because small changes are hidden by the very large attenuation of thermal neutron beam by the hydrogens in the tissues. The detection was successfully performed. Especially, the Super Eye of Hamamatsu Photonics contributed very effectively. Bone marrows and cartilages were also shown clearly. If an efficient and compact neutron source will become available in future, this method will grow up as a powerful tool for biomedical application. (author).

1995-11-01

253

Design of a neutron radiography collimator system in a through beam port at the TRIGA reactor  

Energy Technology Data Exchange (ETDEWEB)

A neutron collimator system is being designed as part of a neutron imaging facility for computed tomography and real-time neutron radiography research at the through beam port of the University of Texas TRIGA reactor. Lack of sufficient information about collimator systems in a through port from the literature necessitated the use of Monte Carlo calculations using the MCNP code 3 to search for optimal design configuration and materials that maximize the thermal neutron intensity at the image plane while minimizing the fast neutrons and gamma radiation.

1996-12-31

254

Mapping Strain in Nanocrystalline Nitinol: an X-ray Diffraction Method (SULI paper)  

Energy Technology Data Exchange (ETDEWEB)

Understanding the mechanical properties of biomedical devices is critical in predicting and preventing their failure in the body. Such knowledge is essential, for example, in the design of biomedical stents, which must undergo repeated strain over their ten year lifetimes without breaking. Computational models are used to predict mechanical response of a device, but these models are not complete; there are significant deviations from the predictions, especially when devices are subjected to repeated multi-axial loads. Improving these models requires comparisons with actual measurements of strained nitinol. Local measurements of the full strain tensor can be made using X-ray diffraction techniques, but they are currently limited to materials whose grain size is larger than the X-ray beam size or require several diffraction patterns produced by rotation of the sample. Nitinol stents are nanocrystalline, with grains smaller than any available ...

2006-01-04

255

Mechanism of the metal-mediated carbalkoxylation of vinyl electrophiles. 1. Preparation, molecular structure, and alcoholysis of vinylic acyl platinum(II) complexes  

Energy Technology Data Exchange (ETDEWEB)

Carbalkoxylation of vinyl electrophiles was investigated using platinum complexes. This reaction occurs in two steps: (a) carbonyl insertion of {sigma}-vinyl Pt(II) halides and (b) alcoholysis of vinylic acyl Pt(II) complexes. Alcoholysis of vinylic acyl Pt(II) triflate complexes is investigated kinetically. Vinylic acyl Pt(II) complexes were isolated and characterized. 51 refs., 5 figs., 6 tabs.

1992-03-01

256

Thermoluminescent (Tl) dosimetry of slow-neutron fields at radiotherapy dose level  

Energy Technology Data Exchange (ETDEWEB)

The dosimetry for radiotherapy involving neutrons is very complicated, owing to the complexity of secondary radiation components, whose contributions to the total absorbed dose have to be discriminated, owing to the different radiobiological effects. In order to separate thermal neutrons and photons, LiF dosimeters are mostly utilized. containing different percentage of Li, like as TLD-700, TLD-100 and TLD-600, but many problems arise. In the response of TLD-700 exposed to neutron-gamma mixed fields with high neutron flux, the contribution of thermal neutrons to the Tl emission is high. Moreover. TLD-100 and TLD-600 may undergo radiation damage, and great care has to be taken in order to obtain reliable results. Other TLDs showing lower sensitivity to neutrons are proposed and experimented for such high-flux neutron fields. The faced ...

2003-07-01

257

Prediction of the delayed neutron yields for actinide nuclides  

Energy Technology Data Exchange (ETDEWEB)

A prediction of delayed neutron yields for actinides which are important in the nuclear energy field is given. The prediction is based on a correlation related to a suggested cluster structure of the nucleus. (author).

1989-01-01

258

Nitride Fuel for Fast Neutron Nuclear Reactors  

International Science & Technology Center (ISTC)

Development of Technology for Producing High-Effective Nitride Fuel UN with Controlled Microstructure for Advanced Fast Neutron Nuclear Reactors

259

Neutrons from interactions of deuterons with lithium isotopes  

International Nuclear Information System (INIS)

Neutron yield from the "6","7Li + d reaction has been investigated. The results obtained are compared with the published data with some theoretical models.

260

Neutron time-of-flight spectroscopy and the reaction "8"8Sr("3He,n)"9"0Zr  

International Nuclear Information System (INIS)

... states helium 3 reactions ion sources mev range 10-100 neutron spectrometers

261

Delayed neutron yields: Time dependent measurements and a predictive model  

Energy Technology Data Exchange (ETDEWEB)

The delayed neutrons from neutron-induced fission in /sup 232/U, /sup 237/Np, /sup 238/Pu, /sup 241/Am, /sup 242/Am/sup m/, /sup 245/Cm, and /sup 249/Cf were studied for the first time; those from /sup 232/Th, /sup 233/U, /sup 235/U, /sup 238/U, /sup 239/Pu, /sup 241/Pu, and /sup 242/Pu were measured again. The data were used to develop an expression for the prediction of the absolute delayed neutron yield, and the prediction of delayed neutron emission with time. This approach accurately predicts observed delayed neutron yields and decay characteristics. A fission product yield model was used in conjunction with delayed neutron emission probability to analytically predict delayed neutron characteristics. The results of this analysis are in excellent agreement with experimental values.

1981-03-01

262

Delayed neutron yield from fast neutron induced fission of sup 2 sup 3 sup 8 U  

CERN Document Server

The measurements of the total delayed neutron yield from fast neutron induced fission of sup 2 sup 3 sup 8 U were made. The experimental method based on the periodic irradiation of the fissionable sample by neutrons from a suitable nuclear reaction had been employed. The preliminary results on the energy dependence of the total delayed neutron yield from fission of sup 2 sup 3 sup 8 U are obtained. According to the comparison of experimental data with our prediction based on correlation properties of delayed neutron characteristics, it is concluded that the value of the total delayed neutron yield near the threshold of (n,f) reaction is not a constant.

2001-01-01

263

Calculation of model neutron stars with pion condensation  

Energy Technology Data Exchange (ETDEWEB)

It is shown numerically that on a time scale of order 1 msec a neutron star with pion condensation will undergo separation into a core and an envelope with a sharp interface. The envelope will not, however, be ejected.

1982-01-01

264
265

A neutron star model in the nonlinear Relativistic Mean-Field Theory  

Energy Technology Data Exchange (ETDEWEB)

The neutron star parameters in the model extended by the inclusion of {delta} meson and additional nonlinear vector meson interactions are studied.

2003-05-19

266

A neutron star model in the nonlinear Relativistic Mean-Field Theory  

International Nuclear Information System (INIS)

The neutron star parameters in the model extended by the inclusion of #delta# meson and additional nonlinear vector meson interactions are studied.

2003-05-19

267

Code requirements document: MODFLOW 2.1: A program for predicting moderator flow patterns  

Energy Technology Data Exchange (ETDEWEB)

Sudden changes in the temperature of flowing liquids can result in transient buoyancy forces which strongly impact the flow hydrodynamics via flow stratification. These effects have been studied for the case of potential flow of stratified liquids to line sinks, but not for moderator flow in SRS reactors. Standard codes, such as TRAC and COMMIX, do not have the capability to capture the stratification effect, due to strong numerical diffusion which smears away the hot/cold fluid interface. A related problem with standard codes is the inability to track plumes injected into the liquid flow, again due to numerical diffusion. The combined effects of buoyant stratification and plume dispersion have been identified as being important in operation of the Supplementary Safety System which injects neutron-poison ink into SRS reactors to provide safe shutdown in the event of safety rod failure. The MODFLOW code discussed here provides transient moderator flow pattern ...

1992-03-01

268

Code requirements document: MODFLOW 2. 1: A program for predicting moderator flow patterns  

Energy Technology Data Exchange (ETDEWEB)

Sudden changes in the temperature of flowing liquids can result in transient buoyancy forces which strongly impact the flow hydrodynamics via flow stratification. These effects have been studied for the case of potential flow of stratified liquids to line sinks, but not for moderator flow in SRS reactors. Standard codes, such as TRAC and COMMIX, do not have the capability to capture the stratification effect, due to strong numerical diffusion which smears away the hot/cold fluid interface. A related problem with standard codes is the inability to track plumes injected into the liquid flow, again due to numerical diffusion. The combined effects of buoyant stratification and plume dispersion have been identified as being important in operation of the Supplementary Safety System which injects neutron-poison ink into SRS reactors to provide safe shutdown in the event of safety rod failure. The MODFLOW code discussed here provides transient moderator flow pattern ...

1992-03-01

269

Phase diagram of SrO-InO1.5-CoOx and a new compound Sr3In0.9Co1.1O6  

International Nuclear Information System (INIS)

Sr3In0.9Co1.1O6, isostructural to Ca3Co2O6, is revealed by the study of the phase relations in the system SrO-InO1.5-CoOx (1000 oC). The structure of Sr3In0.9Co1.1O6 is refined by the combination of powder X-ray and neutron diffraction. Sr3In0.9Co1.1O6 crystallizes in a trigonal lattice with the cell parameters a=b=9.59438(3) A, c=11.02172(4) A with the space group R-3c. Its structure possesses 1D (In/Co)O3 chains running along the c-axis constructed by alternating face-sharing CoO6 octahedra and (In0.9Co0.1)O6 trigonal prisms. The co-occupation of In3+ and Co3+ at the trigonal prismatic site is evidenced by elementary analysis and determined by the structure refinement. Sr3In0.9Co1.1O6 is paramagnetic, and the susceptibility is consistent with the occupation of Co3+ at 10% of the trigonal prismatic positions in a high spin state (HS, S=2). The HS Co3+ is well separated by diamagnetic CoO6 octahedra and InO6 trigonal prisms and shows a g factor ...

2011-04-01

270

Aurivillius phases of PbBi4Ti4O15 doped with Mn3+ synthesized by molten salt technique: Structure, dielectric, and magnetic properties  

International Nuclear Information System (INIS)

Doping of manganese (Mn3+/Mn4+) into the Aurivillius phase Pb1-xBi4+xTi4-xMnxO15 was carried out using the molten salt technique for various Mn concentrations (x=0, 0.2, 0.4, 0.6, 0.8, and 1). Single phase samples could be obtained in the composition range with x up to 0.6 as confirmed by X-ray and neutron diffraction analysis. Dielectric measurements show a peak at 801, 803, 813 and 850 K for samples with x=0, 0.2, 0.4, and 0.6, respectively, related to the ferroelectric transition temperature (Tc). The main contribution of the in-plane polarization for x?0.2 which was calculated from the atomic positions obtained by the structure analysis is the dipole moment in the Ti(1)O6 layer; however, for x?0.4 the polarization originates from the dipole moment in the Ti(2)O6 layer. Mn doping in the Pb1-xBi4+xTi4-xMnxO15 does not show any long range magnetic ordering. -- Graphical abstract: The dipole moment of TiO6 dependence of x in ...

2011-05-01

271

Moessbauer diffraction measurements on polycrystalline bcc iron  

Energy Technology Data Exchange (ETDEWEB)

In the early days of Moessbauer spectroscopy, it was demonstrated that coherent scattering of photons emitted by a Moessbauer source can be observed. In spite of the fact that scattering experiments could give information not accessible by the absorption method, they are not widely used. The reasons for this are, on the one hand, experimental difficulties, and on the other hand, the form of the samples, which should be large single crystals in most cases. In this work, we present a Moessbauer diffraction measurement on polycrystalline bcc iron where these problems have been overcome. We demonstrate that using the kinematical theory of gamma-ray diffraction, useful information on the relative orientation of the crystallographic axis to the hyperfine field directions can be subtracted. (orig.)

1994-11-01

272

Effects of FIB milling and pre-straining on the microstructure of directionally solidified Mo pillars: a Laue diffraction analysis  

Energy Technology Data Exchange (ETDEWEB)

White beam Laue micro-diffraction was performed on directionally solidified, single-crystal Mo pillars in the as-grown state, after focused ion beam (FIB) milling and after pre-straining. The Laue diffraction peaks from the as-grown pillars are very sharp and show no broadening, similar to those from single-crystal Si wafers. Significant broadening and streaking of the peaks occurred after FIB milling and pre-straining, indicative of the damage these treatments induce in the nearly perfect crystal structure of the directionally solidified Mo pillars.

2010-05-01

273

Selective metabolic stimulation of the subfornical organ and pituitary neural lobe by peripheral angiotensin II  

Energy Technology Data Exchange (ETDEWEB)

The subfornical organ is a major receptor area for one of the principal stimuli of thirst, the octapeptide, angiotensin II. In conscious water-sated rats, the authors examined the effects of intravenous infusion of angiotensin II on the rate of glucose utilization in the subfornical organ and in structures anatomically and functionally connected with it. Angiotensin II produced pressor and drinking responses and increased glucose utilization selectively in the subfornical organ and pituitary neural lobe and in no other brain structure. Treatment with the angiotensin II antagonist, sar1-leu8-angiotensin II, before intravenous administration of angiotensin II prevented metabolic stimulation of the subfornical organ and neural lobe. Captopril, an inhibitor of angiotensin-converting enzyme, reduced subfornical organ glucose metabolism to a level similar to that ...

1985-01-01

274

Role of minerals in carbonaceous adsorbents for removal of Pb(II) ions from aqueous solution  

Energy Technology Data Exchange (ETDEWEB)

Adsorptive removal of Pb(II) ions from aqueous solution onto a non-activated charcoal (CC) of oak wood origin was studied in comparison with an activated carbon of coal origin. The adsorption capacity for Pb(II) of the non-activated charcoal increased significantly with deceasing particle diameter, whereas the activated carbon (AC) exhibited approximately constant capacity for Pb(II) adsorption as a function of particle size. Adsorption to the ashes prepared from the non-activated charcoal and the activated carbon was also investigated to examine the role of mineral ash. Although the ash from the activated carbon did not show any Pb(II) adsorption, the ash from the charcoal was very effective for Pb(II) adsorption. Furthermore, Pb(II) was hardly adsorbed when the ash was removed from the non-activated charcoal by acid treatment. Based on the results, the ...

2005-11-01

275

Biosorption of cadmium(II), zinc(II) and lead(II) by Penicillium simplicissimum: Isotherms, kinetics and thermodynamics  

Energy Technology Data Exchange (ETDEWEB)

The isotherms, kinetics and thermodynamics of Cd(II), Zn(II) and Pb(II) biosorption by Penicillium simplicissimum were investigated in a batch system. The effects of pH, initial metal ions concentration, biomass dose, contact time, temperature and co-ions on the biosorption were studied. Adsorption data were well described by both the Redlich-Peterson and Langmuir model. Chemical ion-exchange was found to be an important process based on free energy value from Dubini-Radushkevich isotherm for all metal ions. The results of the kinetic studies of all metal ions at different temperature showed that the rate of adsorption followed the pseudo second-order kinetics well. The thermodynamics constants {delta}G{sup o}, {delta}H{sup o} and {delta}S{sup o} of the adsorption process showed that biosorption of Cd(II), Zn(II) and Pb(II) ions on Penicillium simplicissimum ...

2008-12-30

276

Transurethral Ultrasound Diffraction Tomography  

Science.gov (United States)

... [5] GT Gullberg, RH Huesman, DNG Roy, J. Qi and BW Reutter, Esti- mation of the parameter covariance matrix for a one-compartment cardiac ...

2007-03-01

277

Integrated Optics Interdigitated-Electrode Switches  

Science.gov (United States)

... thus can function as switches -6 ... Akkari, "Optical Channel Waveguide Switch and Coupler ... Wide-Band Guided Wave Acousto-Optic Bragg Diffraction ...

1989-12-31

278

Enhanced Reliability MEMS Deformable Mirrors for Space Imaging ...  

Science.gov (United States)

Sep 3, 2010 ... These higher-quality deformable mirrors will enable diffraction-limited performance for many space-based optical systems such as space-based ...

279

Collaborative Research and Development (CR&D). Delivery ...  

Science.gov (United States)

... 7 Page 11. Figure 5. Diffraction pattern shown a and ~ slip directions with the associated misalignment for single colonies of Ti6242 [2]. 8 Page 12. -- ...

2005-10-01

281

Surprising collectivity in neutron-rich iron isotopes  

International Nuclear Information System (INIS)

... VDPEAZ (Bonn 2010 issue) NUCLEAR PHYSICS AND RADIATION PHYSICS

2010-03-15

283

Si(111)/Gd: A fast and high-resolution thermal neutron detector  

Energy Technology Data Exchange (ETDEWEB)

Recent developments in design and production of thermal neutron detectors based on a crystalline Si diode coupled to a Gd converter are reviewed. The most significant results of neutron test measurements carried out on prototype systems and pointing out the performances of the device are reported. Progress through various detection schemes and technological solutions for the production of a real time neutron counter for routine operation are outlined.

1998-07-01

284

Progress of JAERI neutron science project  

Energy Technology Data Exchange (ETDEWEB)

Neutron Science Project was started at Japan Atomic Energy Research Institute since 1996 for promoting futuristic basic science and nuclear technology utilizing neutrons. For this purpose, research and developments of intense proton accelerator and spallation neutron target were initiated. The present paper describes the current status of such research and developments. (author)

1999-03-01

285

Probing Neutron Star Evolution with Gamma Rays  

Science.gov (United States)

The research sponsored by this grant was conducted in two fields of high-energy astrophysics:

1996-01-01

286

Principium research of real-time neutron radiography in No. 300 reactor  

International Nuclear Information System (INIS)

The characteristics of real-time neutron radiography are described briefly in this paper, and the acquirement of neutron flux, the selection of convertor and the structure of the twilight imaging system and the image-sampling and image-processing system in SPRR-300 reactor are also analyzed detailedly. The experimental result of real-time neutron radiograph is too analyzed in this paper

2002-12-01

287

Neutron-proton mass difference in isospin-asymmetric nuclear matter  

Energy Technology Data Exchange (ETDEWEB)

Isospin-breaking effects in the baryonic sector are studied in the framework of a medium-modified Skyrme model. The neutron-proton mass difference in infinite, asymmetric nuclear matter is discussed. In order to describe the influence of the nuclear environment on the skyrmions, we include energy-dependent charged and neutral pion optical potentials in the s- and p-wave channels. The present approach predicts that the neutron-proton mass difference is mainly dictated by its strong part and that it strongly decreases in neutron matter. (orig.)

2007-06-15

288

Neutron star evolution with internal heating  

Science.gov (United States)

The thermal evolution predicted by current models of the superfluid-crust interaction is noted to

1989-01-01

290

Modifications to the rotating crystal spectrometer  

International Nuclear Information System (INIS)

... bf3 counters data multi-channel analyzers multivibrators neutron spectrometers

291

MCNPX analysis of 68 MeV neutron transmission on iron  

Energy Technology Data Exchange (ETDEWEB)

A 68 MeV neutron transmission experiment on iron has been analyzed with MCNPX using the Los Alamos LA150 neutron data library, the ECN/BRC 150 MeV neutron data library and with the intranuclear cascade code LAHET. The clear improvement of using the data libraries is confirmed. Also, other materials present in LA150 have been checked using the same MCNPX set-up. 10 refs.

1999-02-01

298

Development of a real-time, neutron and gamma dosimeter  

Energy Technology Data Exchange (ETDEWEB)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-07-01

299

Development of a real-time, neutron and gamma dosimeter  

International Nuclear Information System (INIS)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-06-10

301

Demonstration of neutron radiography and computed tomography at the University of Texas thermal neutron imaging facility  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere.

1999-09-01

302

Demonstration of neutron radiography and computed tomography at the University of Texas thermal neutron imaging facility  

International Nuclear Information System (INIS)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere

1999-06-06

304

Albedo method applied to coupled neutron-gamma shielding radiations  

International Nuclear Information System (INIS)

The Albedo Theory was applied in order to develop an one-group algorithm for coupled neutron-gamma shielding calculations. The configuration analyzed consists of multilayered plane systems, where a incident neutron current generates gamma radiation through neutron-gamma reactions. The results obtained by Albedo Method and ANISN code have shown excellent agreement. (author)

2000-10-15

305

APOD: 2004 September 4 - Neutron Mars  

Science.gov (United States)

ice could be responsible for the formation of martian gullies. Tomorrow's picture: whirlpool ...

2011-10-07

306

A novel application of the multi-group method: Coupled neutron-gamma-electron cross-section library  

Energy Technology Data Exchange (ETDEWEB)

A multi-group neutron-gamma cross-section library in DTF-IV format is supplemented with electron production matrix to generate a coupled neutron-gamma-electron library. This is realized by estimating the contributions from Compton scattering, pair production and photoelectric effect to the electron production cross-sections. A novel application of this new library, which involves transport of neutrons, gammas and electrons, for estimating the Compton current due to a pulse of radiation in air is discussed.

2006-02-15

307

A novel application of the multi-group method: Coupled neutron-gamma-electron cross-section library  

International Nuclear Information System (INIS)

A multi-group neutron-gamma cross-section library in DTF-IV format is supplemented with electron production matrix to generate a coupled neutron-gamma-electron library. This is realized by estimating the contributions from Compton scattering, pair production and photoelectric effect to the electron production cross-sections. A novel application of this new library, which involves transport of neutrons, gammas and electrons, for estimating the Compton current due to a pulse of radiation in air is discussed.

2006-02-01

308

Transmutation of americium in fission reactors  

Energy Technology Data Exchange (ETDEWEB)

To get a considerable reduction of the radiotoxicity due to americium, a thermal neutron fluence of 2.10{sup 22} cm{sup -2} or a fast neutron fluence of 2.10{sup 24} cm{sup -2} is required. Irradiation in a thermal neutron flux leads to lower masses of {sup 234}U and precursors and of {sup 237}Np and precursors, but to higher curium masses and much higher neutron emission rates than irradiation in a fast neutron flux. Therefore, irradiation in a fast neutron flux has preference when multiple recycling is adopted. When once-through burning is applied, irradiation in a thermal neutron flux can be applied. Then irradiation in a heavy water reactor (HWR) has preference above irradiation in a PWR or in a high temperature gas-cooled reactor (HTGR). (authors) 4 refs.

1995-12-31

309

Transmutation of americium in fission reactors  

Energy Technology Data Exchange (ETDEWEB)

To get a considerable reduction of the radiotoxicity due to americium, a thermal neutron fluence of 2.10{sup 22} cm{sup -2} or a fast neutron fluence of 2.10{sup 24} cm{sup -2} is required. Irradiation in a thermal neutron flux leads to lower masses of {sup 234}U and precursors and of {sup 237}Np and precursors, but to higher curium masses and much higher neutron emission rates than irradiation in a fast neutron flux. Therefore, irradiation in a fast neutron flux has preference when multiple recycling is adopted. When once-through burning is applied, irradiation in a thermal neutron flux can be applied. Then irradiation in a HWR has preference above irradiation in a PWR or in a HTGR. (orig.).

1995-06-01

310

Study of a loop heat pipe using neutron radiography.  

Science.gov (United States)

An explanation is given of what a loop heat pipe (LHP) is, and how it works. It is then shown that neutron imaging (both real time neutron radioscopy and single exposure neutron radiography) is an effective experimental tool for the study of LHPs. Specifically, neutron imaging has helped to identify and correct a cooling water distribution problem in the condenser, and has enabled visualization of two-phase flow (liquid and vapor) in various components of the LHP. In addition, partial wick dry-out, a phenomenon of great importance in the effective operation of LHPs, is potentially identifiable with neutron imaging. It is anticipated that neutron radioscopy and radiography will greatly contribute to our understanding of LHP operation, and will lead to improvement of LHP modeling and design. PMID:15246420

2004-10-01

311

Study of a loop heat pipe using neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

An explanation is given of what a loop heat pipe (LHP) is, and how it works. It is then shown that neutron imaging (both real time neutron radioscopy and single exposure neutron radiography) is an effective experimental tool for the study of LHPs. Specifically, neutron imaging has helped to identify and correct a cooling water distribution problem in the condenser, and has enabled visualization of two-phase flow (liquid and vapor) in various components of the LHP. In addition, partial wick dry-out, a phenomenon of great importance in the effective operation of LHPs, is potentially identifiable with neutron imaging. It is anticipated that neutron radioscopy and radiography will greatly contribute to our understanding of LHP operation, and will lead to improvement of LHP modeling and design.

2004-10-01

312

Study of a Loop Heat Pipe Using Neutron Radiography  

Energy Technology Data Exchange (ETDEWEB)

An explanation is given of what a loop heat pipe (LHP) is, and how it works. It is then shown that neutron imaging (both real time neutron radioscopy and single exposure neutron radiography) is an effective experimental tool for the study of LHPs. Specifically, neutron imaging has helped to identify and correct a cooling water distribution problem in the condenser, and has enabled visualization of two-phase flow (liquid and vapor) in various components of the LHP. In addition, partial wick dry-out, a phenomenon of great importance in the effective operation of LHPs, has been identified with neutron imaging. It is anticipated that neutron radioscopy and radiography will greatly contribute to our understanding of LHP operation, and will lead to improvement of LHP modeling and design.

2001-08-01

313

Real-time neutron monitoring method using an imaging plate  

Energy Technology Data Exchange (ETDEWEB)

A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)

1999-07-01

314

Real-time neutron monitoring method using an imaging plate  

International Nuclear Information System (INIS)

A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)

1999-04-19

315

Relationships between cosmic ray neutron flux and rain flows  

International Nuclear Information System (INIS)

The registration of secondary cosmic ray neutrons is a convenient tool for the investigation of primary cosmic ray variations and for meteorological effects as well. At present a large network of neutron monitors exists, aiming at studies of cosmic ray variations which are related to interplanetary conditions and geomagnetic activity. At the same time cosmic ray variations may be related to some atmospheric processes. In this connection, using the data from two neutron monitors (a standard and a lead free one), a gamma detector from Moscow station and lead free neutron monitor at BEO Moussala, we studied the correlations between rain flows and neutron flux. In this study we used daily averages on the basis of 10 min data for the neutron flux, corrected for barometric pressure and data from local meteo-stations. The preliminary analysis indicates a correlation ...

2008-09-01

316

Real-time neutron radiography system performance - Measurements and methods  

Energy Technology Data Exchange (ETDEWEB)

The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible ...

1988-09-01

317

Real-time neutron radiography system performance - Measurements and methods  

International Nuclear Information System (INIS)

The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of monitoring any changes in the real-time ...

1988-01-01

318

Quality Management for Neutron Transmutation Doping of Silicon Ingot in HANARO  

Energy Technology Data Exchange (ETDEWEB)

By using this doping method, silicon semiconductors with extremely uniform dopant distributions can be produced, and this is the dominant advantage of NTD compared with a conventional chemical doping. Good uniformity of a dopant concentration is usually required for high power applications such as thyristor (SCR), IGBT, IGCT and GTO and for special sensors. Achieving an accurate neutron fluence corresponding to a target resistivity as well as a uniform irradiation is the prime target of a neutron irradiation for NTD. Generally, in order to reach an accurate neutron fluence, a real time neutron flux is monitored by a neutron detector such as a Self-powered Neutron Detector(SPND). And, after an irradiation, the total irradiation fluence is confirmed by measuring the absolute activity of a neutron activation sample that has been irradiated with ...

2007-10-15

319

Development of a phoswich detector to detect neutrons in the charged-particle mixed field  

Energy Technology Data Exchange (ETDEWEB)

Manned-space missions bring an exposure due to corpuscular radiations of which nature is quite different from what we encounter in the ground environment. In the space environment, many secondaries are produced through interactions of cosmic ray primaries with the spacecraft wall and other surrounding materials. Among this large variety of radiation components in the space, the contribution of neutrons to the radiation exposure of astronauts has remained to be studied. Up to today, efforts to measure neutron dose equivalent have been made using passive detector systems. Considering uncertainties involved in current measurements and estimations of high energy neutrons, and their increasing importance for future manned missions, it is necessary to measure neutron spectrum in the spacecraft under realistic conditions. The neutron spectra have never been measured on board a spacecraft, ...

1997-07-01

320

Characterization of 3D thermal neutron semiconductor detectors  

International Nuclear Information System (INIS)

Neutron semiconductor detectors for neutron counting and neutron radiography have an increasing importance. Simple silicon neutron detectors are combination of a planar diode with a layer of an appropriate neutron converter such as 6LiF. These devices have limited detection efficiency of not more than 5%. The detection efficiency can be increased by creating a 3D microstructure of dips, trenches or pores in the detector and filling it with a neutron converter. The first results related to the development of such devices are presented. Silicon detectors were fabricated with pyramidal dips on the surface covered with 6LiF and then irradiated by thermal neutrons. Pulse height spectra of the energy deposited in the sensitive volume were compared with simulations. The detection efficiency of these devices was about 6.3%. Samples with different ...

2007-06-11

321

The influence of the strength of hyperon-hyperon interactions on neutron star properties  

Energy Technology Data Exchange (ETDEWEB)

An equation of state of neutron star matter with strange baryons has been obtained. The effects of the strength of hyperon-hyperon interactions on the equations of state constructed for the chosen parameter sets have been analysed. Numerous neutron star models show that the appearance of hyperons is connected with the increasing density in neutron star interiors. The performed calculations have indicated that a change of the hyperon-hyperon coupling constants affects the chemical composition of a neutron star. The obtained numerical hyperon star models exclude a large population of strange baryons in the star interior.

2005-09-01

322

Resonance spin-echo option on neutron reflectometers for the study of dynamics of surfaces and interfaces  

Energy Technology Data Exchange (ETDEWEB)

The applications of neutron reflectometry to study dynamic phenomena at surface and interfaces have been restricted so far. This was mainly due to the low intensity of neutron sources, but now high-intensity spallation neutron sources are under construction in Japan (J-PARC) and US (SNS). We are planning to install a spin-echo option on the J-PARC neutron reflectometer with horizontal sample geometry for studies of dynamics of surfaces and interfaces. This option is based on the resonance spin-echo method and aimed at dynamics up to hundreds of nanoseconds. In this contribution, the plan and status of development are introduced together with the principle and characteristics of this option.

2005-02-15

323

Polarized triple-axis spectrometer TASP  

Energy Technology Data Exchange (ETDEWEB)

The polarized triple-axis spectrometer TASP at SINQ has been optimized for measuring magnetic cross sections in condensed matter. The neutrons are polarized or analyzed either by means of benders or Heusler monochromators. The beam divergence, i.e. the intensity, and the spectral range of the neutrons is rather large because of the supermirror coatings of the feeding neutron guide. The intensity can be further increased at the sample position by means of a focussing monochromator and a focussing anti-trumpet. The end position of TASP allows the tailoring of the neutron beam already before the monochromator and to scatter neutrons over very wide ranges of angles. (author) 6 figs., 1 tab., 8 refs.

1996-11-01

324

Neutron monitoring on cold fusion experiments  

International Nuclear Information System (INIS)

A helium-3 proportional detector was equipped with the experiment of Liaw-type electrolytic cell contained eutectic LiCl-KCl molten salt saturated by LiD electrolytic to collect the informations of the rate and the energy distribution of possible neutron produced during the electrolysis processes. For long time monitoring, the significant reproducible neutron bursts appeared at several runs of cells during electrolytic processing. The neutron counting rate increased about a factor of two above the level of the background measurement. The pulse height signals were verified of neutron energy ranging from thermal up to 350 keV. (author).

1992-10-01

325

Method and system for detecting explosives  

Energy Technology Data Exchange (ETDEWEB)

A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

2009-03-10

326

Measurement of the energy dependence of the neutron fission cross section of /sup 242/Am/sup m/  

Energy Technology Data Exchange (ETDEWEB)

Measurements were made of the cross section for /sup 242/Am/sup m/ fission induced by neutrons in the energy range 0.04< or =E/sub n/< or =4.52 MeV as well as by neutrons with E/sub n/roughly-equal14.8 MeV. An electrostatic generator and a low-voltage accelerating tube were used to generate the quasimonochromatic neutrons. Measurements in the low-energy region were made by using the time-of-flight technique in neutrons from a nuclear explosion. Results of the measurements are compared with previously published data.

1981-03-01

327

Low cost, low power, high sensitivity, real time neutron detection microsystem  

International Nuclear Information System (INIS)

A Si array neutron detector is proposed based on commercial CCD and CMOS sensor technology coupled with a thin film neutron conversion coating. System sensitivity is estimated for a baseline device containing a single array and various schemes to increase detection probability by simple area scaling and stacking are discussed. Some possible use scenarios are discussed involving static and moving sources. Likely neutron source fluxes for weapons grade and commercial grade nuclear material are estimated along with expected intensities of cosmic background neutrons which would establish a noise floor to detection limits.

2002-10-10

328

Fission neutron multiplicity for the /sup 242m/Am(n,f) reaction  

International Nuclear Information System (INIS)

This paper analyzes fission neutron multiplicity for the /sup 242m/Am(n,f) reaction. The fission neutron multiplicity, v bar, of /sup 242m/Am(n,f) was measured relative to that of /sup 235/U(n,f) using the neutron time-of-flight facility at the Lawrence Livermore National Laboratory 100-MeV electron Linac. A comparison of the measured energy dependence of v-bar is made with semi-empirical models of neutron emission from the actinides. 22 refs.

329

Explosives detection system and method  

Energy Technology Data Exchange (ETDEWEB)

A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

2007-12-11

330

Direct interactions in neutron inelastic scattering spectra  

International Nuclear Information System (INIS)

Inelastically scattered neutron spectra and angular distributions measured for a number of nuclei at the 9.1 and 14.4 MeV incident neutron energies are fitted well as a sum of neutron evaporation spectrum and the direct interaction part. For the last one the practical scheme of parametrization based on direct interaction theory is presented. The relative contribution of direct interactions in double differential cross sections and parameters of neutron evaporation spectra have been evaluated. All results have a simple physical interpretation and may be useful at interpolating of data in a wide energy interval.

1976-07-06

331

Application of the neutron television fluoroscopic system to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).

1984-10-01

332

Application of the neutron television fluoroscopic system to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter.

1984-10-01

333

An application of the neutron television fluoroscopic system to neutron computed tomography  

International Nuclear Information System (INIS)

Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).

1984-10-01

334

Time-dependent, Bianchi II, rotating universe  

International Nuclear Information System (INIS)

An exact cosmological solution of Einstein's equations which has time-dependent rotation is presented. The t-constant sections are of Bianchi type II. The source of this geometry is a fluid which has not been thermalized. (Author).

2006-11-03

336

Site-specific modification of albumin by free radicals. Reaction with copper(II) and ascorbate.  

UK PubMed Central (United Kingdom)

Exposure of albumin to Cu(II) (10-100 microM) and ascorbate (0.1-2 mM) results in extensive molecular modifications, indicated by decreased fluorescence and chain breaks. The rate of utilization of...Full Text Available

1986-06-01

337

Rome II Versus Rome III Classification of Functional Gastrointestinal Disorders in Pediatric Chronic Abdominal Pain  

UK PubMed Central (United Kingdom)

ObjectivesThe updated Rome III criteria for pediatric functional gastrointestinal disorders (FGIDs) include new FGID categories and changes to the Rome II criteria...Full Text Available

2008-09-01

338

Presence of preactivated T cells in hemodialyzed patients: their possible role in altered immunity.  

UK PubMed Central (United Kingdom)

Interleukin 2 (IL-2) and B-cell growth factors I and II (BCGF I and BCGF II) are lymphokines produced by T cells that play a major role in T- and B-cell cooperation. Peripheral blood lymphocytes from...Full Text Available

1986-10-01

340

Plasma Electric Potential Evolution at the Core and Edge of the TJ-II Stellarator and T-10 Tokamak  

International Nuclear Information System (INIS)

In this article are presented main results on electric potential investigations in stellarator/torsatron TJ-II and tokamak T-10 in a comparable regimes of device operation.

2006-01-01

341

Partial Purification and Characterization of Aminopeptidase II from Chara australis  

UK PubMed Central (United Kingdom)

Aminopeptidase II, one of the two major aminopeptidases in the giant alga Chara australis, was partially purified. Its molecular weight was estimated to be about 80,000 by gel permeation...Full Text Available

1989-02-01

343

MultiRTA: A simple yet reliable method for predicting peptide binding affinities for multiple class II MHC allotypes  

UK PubMed Central (United Kingdom)

BackgroundThe binding of peptide fragments of antigens to class II MHC is a crucial step in initiating a helper T cell immune response. The identification of such peptide epitopes...Full Text Available

344

Interactions of metal cations with anionic groups on the cell Wall of the macroalga vaucheria sp.  

Energy Technology Data Exchange (ETDEWEB)

The aim of this article was to investigate the interactions of metal cations in aqueous solutions with the biomass of the freshwater macroalga Vaucheria sp. This problem is important when elaborating new applications of biosorption, e.g. the production of mineral feed additives for livestock from the biomass of algae enriched with microelement ions. Potentiometric titration was applied as a quick and cheap screening test to search for new efficient biosorbents. It revealed a variety of functional groups capable of cation exchange on the macroalgal surface, including carboxyl, phosphate, hydroxyl or amino groups. Fourier transform infrared spectroscopy on natural and chromium-loaded Vaucheria sp. confirmed that carboxyl groups played a dominant role in the biosorption. The study also showed that Ca(II), Na(I), K(I), and Mg(II) ions were released from the biomass after biosorption of Cu(II), Mn(II), ...

2010-06-15

345

Human Pol II promoter recognition based on primary sequences and free energy of dinucleotides  

UK PubMed Central (United Kingdom)

BackgroundPromoter region plays an important role in determining where the transcription of a particular gene should be initiated. Computational prediction of eukaryotic Pol II promoter...Full Text Available

346

Examination of the Rotazyme II enzyme immunoassay for the diagnosis of rotavirus gastroenteritis.  

UK PubMed Central (United Kingdom)

Rotazyme II, which is a shorter version of Rotazyme (less than 3 h), was compared with electron microscopy and Rotazyme for sensitivity and specificity on 229 human stool specimens. Compared with electron...Full Text Available

1985-09-01

347

Equilibrium and thermodynamic parameters of single and binary mixture biosorption of lead (II) and copper (II) ions onto Pseudomonas putida: Effect of temperature  

Energy Technology Data Exchange (ETDEWEB)

The biosorption of lead (II) and copper (II) ions, single component and binary systems, by dried P. putida was investigated in a batch system. The effects of initial pH, temperature, initial single and binary mixture concentrations on the biosorption kinetics and equilibrium uptake of each component, both single and binary mixtures were investigated. The bacterial biomass exhibited the highest single and binary lead (II) and copper (II) ions uptake capacity at 25 and 30 deg. C, respectively, the initial pH value of 5.5 and at the initial metal ions concentration of 100 mg dm{sup -3}. The Freundlich and Langmuir adsorption models were used for the mathematical description of the biosorption equilibrium and isotherm constants were evaluated at different temperatures. Adsorption data were well described by the Langmuir model, although they could be modeled by the Freundlich equation. The thermodynamics ...

2006-07-31

348

Effects of Perfluorocarbons on surfactant exocytosis and membrane properties in isolated alveolar type II cells  

UK PubMed Central (United Kingdom)

BackgroundPerfluorocarbons (PFC) are used to improve gas exchange in diseased lungs. PFC have been shown to affect various cell types. Thus, effects on alveolar type II (ATII) cells...Full Text Available

2010-01-01

349

Conditional deletion of Abca3 in alveolar type II cells alters surfactant homeostasis in newborn and adult mice  

UK PubMed Central (United Kingdom)

ATP-binding cassette A3 (ABCA3) is a lipid transport protein required for synthesis and storage of pulmonary surfactant in type II cells in the alveoli. Abca3 was conditionally deleted...Full Text Available

2010-05-01

350

Complex Impedance Studies of Electrosprayed and Extruded ...  

Science.gov (United States)

... Page 66 List of Figures Figure II.A.1 Simple Fuel Cell Model Page 8 ... Carbon Electrodes Figure II.A.1 Simple Fuel Cell Model Page 11. 9 ...

2004-05-05

351

Biphasic targeting and cleavage furrow ingression directed by the tail of a myosin II  

UK PubMed Central (United Kingdom)

Cytokinesis in animal and fungal cells utilizes a contractile actomyosin ring (AMR). However, how myosin II is targeted to the division site and promotes AMR assembly, and how the AMR coordinates with...Full Text Available

2010-12-27

352

Anaerobic reactions of Rhus vernicifera laccase and its type-2 copper-depleted derivatives with hexacyanoferrate(II).  

UK PubMed Central (United Kingdom)

Anaerobic reactions of Rhus vernicifera laccase and its type-2 copper-depleted derivatives with hexacyanoferrate(II) were investigated by absorption and e.s.r. spectroscopy. When native laccase was...Full Text Available

1992-06-15

353

Albumin binding of photobilirubin II.  

UK PubMed Central (United Kingdom)

Photobilirubin II, a stereoisomer of bilirubin, binds to human serum albumin at a single binding site (K = 2.2 x 10(6)M-1), presumably the high-affinity bilirubin-binding site. Binding in the secondary...Full Text Available

1983-07-01

354

A Systematic Assessment of MHC Class II Peptide Binding Predictions and Evaluation of a Consensus Approach  

UK PubMed Central (United Kingdom)

The identification of MHC class II restricted peptide epitopes is an important goal in immunological research. A number of computational tools have been developed for this purpose, but there is a lack...Full Text Available

2008-04-01

355

1996 Hazardous Substances and New Organisms No. 30  

Wastenet

ii) Flammability: (iii) A capacity to oxidise: (iv) Corrosiveness: (v) Toxicity (including chronic ...an explosion or fire: (d) For substances with corrosive properties: (i) To reduce the ...likelihood of any unintended corrosion:(ii) To control the adverse effects of any corrosion:

356

X-ray diffraction studies of palladium silicide thin films  

Energy Technology Data Exchange (ETDEWEB)

The solid state reaction between a Pd thin film and a Si substrate produces a single new phase, Pd/sub 2/Si, for temperatures <700/sup 0/C. When the substrate is a single crystal of (111) surface orientation, this process is particularly interesting because the silicide grows epitaxially. Growth of epitaxial interfacial Pd/sub 2/Si was the focus of this study using X-ray diffraction techniques.

1985-01-01

357

The influence of self-diffraction on two-wave mixing for counterpropagating geometry  

Science.gov (United States)

Two-wave mixing in sillenite crystals such as bismuth silicon oxide (Bi12SiO20) and bismuth titanium oxide (Bi12TiO20) of (001)- and (221)-cuts for counterpropagating geometry was studied within the frame of slowly varying amplitude approximation. Electrooptic, photoelastic, piezoelectric, self-diffraction effects and optical activity were taken into account.

2005-06-01

358

The different structural scales of the breast and their impact on time-of-flight and diffraction tomography  

Energy Technology Data Exchange (ETDEWEB)

Ultrasound tomography is an attractive imaging method for the detection of breast cancer. The complex anatomy of the breast with its different spatial scales and material property contrasts make accurate reconstructions very challenging. This paper proposes a hybrid approach whereby Travel-of-Flight and Diffraction Tomography are combined together to achieve high-resolution and high-accuracy sound-speed reconstructions. The method is validated with several numerical phantoms.

2010-01-01

359

Changes in the profile structure of the sarcoplasmic reticulum membrane induced by phosphorylation of the Ca2+ ATPase enzyme in the presence of terbium: a time-resolved x-ray diffraction study.  

UK PubMed Central (United Kingdom)

The design of the time-resolved x-ray diffraction experiments reported in this and an accompanying paper was based on direct measurements of enzyme phosphorylation using [gamma-32P]ATP that were employed...Full Text Available

1994-05-01

360

Investigations on solar grade silicon and process engineering of advanced silicon solar cells  

Energy Technology Data Exchange (ETDEWEB)

This thesis deals with the evaluation of Solar Grade Silicon (SoG-Si) purified by different techniques, and also the fabrication and characterization of high efficiency and advanced bifacial solar cells. In the beginning of Chapter 1, various SoG-Si production methods relevant for this work are qualitatively described. The three feedstock materials used in this work are from the Fluidized Bed Reactor (FBR) process, metallurgical feedstock-I and feedstock-II process. In metallurgical feedstock-I, the lifetime of the minority charge carriers in multicrystalline silicon (mc-Si) samples at the grain boundaries are found to be higher than the grains themselves possibly due to lower resistivities in the grain boundaries. The efficiency of the best solar cell obtained using the mc-Si metallurgical feedstock-I is 16.1%. It has been identified that the fast light induced degradation, whose magnitude is lower than that of a reference cell suggests the formation of a B-metal ...

2007-07-01

362

To Repair or to Rebuild? Analyzing Personnel Security ...  

Science.gov (United States)

... Screening Adjudication Monitoring Applicants of Information Behavior II I Conducting Investigations ... Applicants of Information Behavior Conducting ...

1988-09-01

363

Titanate nanotubes as superior adsorbents for removal of lead(II) ions from water  

British Library Electronic Table of Contents (United Kingdom)

Titanate nanotubes were hydrothermally synthesized and their adsorption performances for lead(II) ion removal were studied. The results showed that titanate nanotubes ruptured in the adsorption process resulting in two distinct adsorption stages, thus achieving a maximum adsorption capacity of 3.752mmolg^-^1 of lead(II). Furthermore, it was found that the regeneration of titanate nanotubes loaded with the lead(II) ions can be readily achieved using the saturated EDTA disodium salt aqueous solution, thereby avoiding the trouble of disposal of adsorbent. The adsorption mechanism was also discussed in detail.

2010-01-01

365

STUDY OF BRUCELLA POLYSACCHARID ANTIGENES. II. ...  

Science.gov (United States)

... 1959). It was not possible for us, however, to detect any reaction of this type in the annials immunized with brucela. Considering ...

1965-04-26

367

JPRS Report, Nuclear Developments  

Science.gov (United States)

... II. Nuclear Purification Nuclear purity is achieved with the help of the treatment of commercial concentrates of uranium ("yellow cake"). ...

1988-06-03

368

Electroluminescence Study of Green Be-Contained II-VI ...  

Science.gov (United States)

... laser structure. However, still the greater part (60%) of emitted photons is a result of a spontaneous radiation process. In ...

2000-06-23

370

COST EVALUATION AND COST ESTIMATING FOR ...  

Science.gov (United States)

... Accession Number : AD0833945. Title : COST EVALUATION AND COST ESTIMATING FOR SHIPBOARD ELECTRONIC EQUIPMENT. VOLUME II. ...

1967-04-01

371

COMBUSTIBLE AMMUNITION FOR SMALL ARMS. 1. ...  

Science.gov (United States)

... Research on development of combustible cartridge cases for small arms was conducted in Germany during World War II. ...

1960-05-01

372

Adsorption of ammonia and pyridine on copper(II)-doped magnesium-exchanged smectite clays studied by electron spin resonance  

Science.gov (United States)

The interaction between N-donor adsorbates such as ammonia and pyridine with Cu(II)-exchanged montmorillonite, beidellite, flourohectorite into smectite clays has been studied by electron spin resonance. Cu(II) cations exchanged into smectites coordinate five ammonia or pyridine molecules in beidellite, four ammonia of pyridine molecules in hydroxyhectorite. Thus, the Cu(II) cations bound to the interior surfaces of these smectite clays constitute strong Lewis acid sites. 26 refs., 7 figs., 1 tab.

1993-01-14

373

A type II arabinogalactan isolated from an infusion of Maytenus ilicifolia  

International Nuclear Information System (INIS)

English 2005 [1 p.] Brazil Cipriani, TR Mellinger, CG Sassaki, GL Gorin,

2005-07-02

375

MACHO observations of Type II cepheids and RV Tauri Stars in the LMC  

Science.gov (United States)

We report the of the existence of RV Tauri stars in the Large Magellanic Cloud (LMC). This class of variable star has hitherto been unidentified in the Magellanic Clouds. In light and color curve behavior the RV Tauri stars appear to be an extension of the Type II Cepheids to longer periods. A single period-luminosity-color relationship is seen to describe both the Type II Cepheids and the RV Tauri stars in the LMC.

1996-07-01

376

Insulin-like growth factor II receptor is phosphorylated by a tyrosine kinase in adipocyte plasma membranes  

Energy Technology Data Exchange (ETDEWEB)

Incorporation of /sup 32/P from (gamma-32P)ATP into tyrosine residues of the insulin-like growth factor (IGF)-II receptor was observed in a Triton X-100-insoluble fraction of rat adipocyte plasma membranes. IGF-II receptor phosphorylation proceeded to a stoichiometry of approximately 0.5 mol of phosphate/IGF-II binding site after 10 min of incubation at 4 degrees C. A Km for ATP of 6 microM was calculated for this phosphorylation reaction. Addition of IGF-II caused an approximately 2-fold increase in tyrosine phosphorylation of the IGF-II receptor in this preparation. In contrast, phosphorylation of angiotensin II by the Triton X-100 washed membranes was not stimulated by IGF-II. Incubation of purified receptor immobilized on IGF-II agarose or of receptor-enriched low density microsomal membranes with (gamma-32P)ATP did ...

1986-06-15

377

Fragrance mix II in the baseline series contributes significantly to detection of fragrance allergy  

DEFF Research Database (Denmark)

Fragrance mix II (FM II) is a relatively new screening marker for fragrance contact allergy. It was introduced in the patch test baseline series in Denmark in 2005 and contains six different fragrance chemicals commonly present in cosmetic products and which are known allergens.

2010-01-01

378

Campylobacter jejuni Fatty Acid Synthase II: Structural and functional analysis of ?-hydroxyacyl-ACP dehydratase (FabZ)  

UK PubMed Central (United Kingdom)

Fatty acid biosynthesis is crucial for all living cells. In contrast to higher organisms, bacteria use a type II fatty acid synthase (FAS II) composed of a series of individual proteins, making...Full Text Available

2009-03-06

379

The response of some TL albedo neutron dosimeters  

International Nuclear Information System (INIS)

As part of a general study of personnel neutron dosimetry systems, three British and two German TL albedo dosimeters were compared. They range from simple albedo devices to multi-element devices which detect combinations of incident and albedo neutrons. They were exposed to beams of mono-energetic neutrons, a thermal neutron column and a "2"5"2Cf source. The variation in response with neutron energy above 0.1 MeV was similar for all dosimeters. The resuls show that in general multi-component dosimeters fo not provide enough information to deduce the effective energy of incident neutrons. The choice of single or multi-element dosimeters for particular types of environment is discussed. The Harvey dosimeter has the most acceptable thermal neutron response of the simpler devices. For neutron energies below 0.5 MeV its ...

380

System suitable for use in neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

A system for real-time neutron radiography of moving objects is described. It comprise a source adapted to generate a continuous uninterrupted series of neutron pulses. Each pulse has a predetermined peak power and duration compatible with the framing times of a real-time video imaging system. A transporter moves an object to be examined to bring sequentially position selected portions of the object in the path of the pulses. Where the object itself has moving components, pulses are sequentially incident on the object. According to any dissimilarities, the object will alter the intensity of the neutrons passing therethrough. In order to record separately the changes in the neutron intensity, for each pulse, an imager is positioned to receive the neutron beam pulses which have been altered by their passage through the object and produce images indicating intensity alterations. A ...

1990-02-07

381

System suitable for use in neutron radiography  

International Nuclear Information System (INIS)

A system for real-time neutron radiography of moving objects is described. It comprise a source adapted to generate a continuous uninterrupted series of neutron pulses. Each pulse has a predetermined peak power and duration compatible with the framing times of a real-time video imaging system. A transporter moves an object to be examined to bring sequentially position selected portions of the object in the path of the pulses. Where the object itself has moving components, pulses are sequentially incident on the object. According to any dissimilarities, the object will alter the intensity of the neutrons passing therethrough. In order to record separately the changes in the neutron intensity, for each pulse, an imager is positioned to receive the neutron beam pulses which have been altered by their passage through the object and produce images indicating intensity alterations. A ...

1988-07-20

382

Surface physics with cold and thermal neutron reflectometry. Progress report, April 1, 1991--September 30, 1993  

Energy Technology Data Exchange (ETDEWEB)

Within the past two and one half years of the project ``Surface Physics With Cold and Thermal Neutron Reflectometry`` a new thermal neutron reflectometer was constructed at the Rhode Island Nuclear Science Center (RINSC). It was used to study various liquid and solid surfaces. Furthermore, neutron reflection experiments were be un at different laboratories in collaboration with Dr. G.P. Fetcher (at Argonne National Laboratory), Dr. T. Russell (IBM Almaden) and Drs. S.K. Satija and A. Karim (at the National Institute for Standards and Technology). The available resources allowed partial construction of an imaging system for ultracold neutrons. It is expected to provide an extremely high resolution in momentum and energy transfer in surface studies using neutron reflectometry. Much of the work reported here was motivated by the possibility of later implementation at the planned ...

1993-09-01

383

Optimization of neutron-to-light converter screens for use in real-time neutron radiography  

International Nuclear Information System (INIS)

In neutron radiography, as in other forms of NDE, it is sometimes desirable to observe dynamic events. This need has generated increased interest in the development of real-time neutron radiography systems and neutron-to-light converter screens optimized for real-time application. Two screens currently available at MURR are: (1) a 0.041-cm-thick Gd_2O_2S screen manufactured by 3M Company and (2) a "6KiF-ZnS(Ag) screen (NE 426) manufactured by Nuclear Enterprises. These screens are presently used in conventional film neutron radiography and represent two of the commercially available screens that have demonstrated the greatest resolution and sensitivity. Unfortunately, these screens have severe limitations when used for real-time neutron radiography. In order to isolate and minimize the factors contributing to these limitations, several neutron absorbers and ...

1982-04-01

384

Fluid flow visualization with neutron radiography. [Using collimated beam of neutrons  

Energy Technology Data Exchange (ETDEWEB)

A technique was developed that permits fluid flow to be visualized even where the flow is completely shrouded by metal. The technique employs real-time neutron radiography, which is similar to x-ray radiography except a collimated beam of neutrons is used. Various combinations of neutron-opaque tracer materials were tested with neutron-transparent fluid. Neutron opaque tracers, such as solid particles, fluid droplets, and streaklines were imaged through metal walls as they convected in neutron-transparent ambient fluid. Visualization of bubbles/voids were evaluated for possible future applications. Surface-flow patterns were also imaged by using neutron-opaque tufts. These techniques were evaluated for image contrast, resolution, and the ability to accurately track fluid flow fields. The techniques were also modeled to optimize contrast in ...

1991-01-01

385

Delayed-neutron energy spectra following thermal-neutron-induced fission of Pu-239  

Energy Technology Data Exchange (ETDEWEB)

Delayed-neutron (DN) energy spectra following thermal neutron induced fission of /sup 239/Pu as a function of time after fission have been measured, using the beta-neutron time-of-flight (TOF) spectrometer at the University of Lowell. Thermal/epithermal neutrons were produced on the 5.5-MV Van de Graaff accelerator using the /sup 7/Li(p,n)/sup 7/Be reaction. Time spectra over the neutron energy range of 0.01-4.0 MeV were measured for seven different time intervals after fission, each interval containing varying contributions from the six delayed neutrons groups. The DN energy spectra following induced thermal fission of /sup 239/Pu are compared to those resulting from induced thermal fission of /sup 235/U for each of the seven delay time intervals. Decomposition of the measured spectra into six-group DN spectra was accomplished employing an iterative ...

1987-01-01

386

DOE personnel neutron dosimetry evaluation and upgrade program  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for ...

1988-10-01

387

Coated semiconductor devices for neutron detection  

Energy Technology Data Exchange (ETDEWEB)

A device for detecting neutrons includes a semi-insulated bulk semiconductor substrate having opposed polished surfaces. A blocking Schottky contact comprised of a series of metals such as Ti, Pt, Au, Ge, Pd, and Ni is formed on a first polished surface of the semiconductor substrate, while a low resistivity ("ohmic") contact comprised of metals such as Au, Ge, and Ni is formed on a second, opposed polished surface of the substrate. In one embodiment, n-type low resistivity pinout contacts comprised of an Au/Ge based eutectic alloy or multi-layered Pd/Ge/Ti/Au are also formed on the opposed polished surfaces and in contact with the Schottky and ohmic contacts. Disposed on the Schottky contact is a neutron reactive film, or coating, for detecting neutrons. The coating is comprised of a hydrogen rich polymer, such as a polyolefin or paraffin; lithium or lithium fluoride; or a heavy metal fissionable material. By varying the ...

2002-01-01

388

Boron-Lined Neutron Detector Measurements  

Energy Technology Data Exchange (ETDEWEB)

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in ...

2009-11-02

389

The thermal neutron sensitivities of SEI and Toshiba FD-P10-7 radiophotoluminescent glass dosimeters  

Energy Technology Data Exchange (ETDEWEB)

The themal neutron sensitivities of SEI and Toshiba FD-P10-7 radiophotoluminescent silver activated metaphosphate glass dosimeters have been measured and studied theoretically. The graphite thermal neutron column attached to the AEEW reactor NESTOR was utilised as a source of thermal neutrons with minimal fast neutron and gamma-ray contamination. Both the neutron removal and gamma correction measurement techniques were applied and these gave consistent results. It was found that the thermal neutron sensitivity of the Toshiba dosimeters is comparable to the most neutron intensitive thermoluminescent materials available. Because of their larger size and higher silver concentration, however, SEI dosimeters are an order of magnitude more neutron sensitive. The neutron sensitivity of FD-7 glass has not ...

1990-01-01

390

The thermal neutron sensitivities of SEI and Toshiba FD-P10-7 radiophotoluminescent glass dosimeters  

International Nuclear Information System (INIS)

The themal neutron sensitivities of SEI and Toshiba FD-P10-7 radiophotoluminescent silver activated metaphosphate glass dosimeters have been measured and studied theoretically. The graphite thermal neutron column attached to the AEEW reactor NESTOR was utilised as a source of thermal neutrons with minimal fast neutron and gamma-ray contamination. Both the neutron removal and gamma correction measurement techniques were applied and these gave consistent results. It was found that the thermal neutron sensitivity of the Toshiba dosimeters is comparable to the most neutron intensitive thermoluminescent materials available. Because of their larger size and higher silver concentration, however, SEI dosimeters are an order of magnitude more neutron sensitive. The neutron sensitivity of FD-7 glass has not ...

391

Simulation technologies for cosmic ray neutron-induced soft errors: Models and simulation systems  

Energy Technology Data Exchange (ETDEWEB)

The authors review two types of simulators for the analysis of cosmic ray neutron-induced soft errors (SE's). One of them is the neutron-induced soft error simulator (NISES). A recently proposed nuclear reaction theory forms the foundation for the nuclear reaction database used in NISES. The other simulator, the simplified simulator MBGR, is based on a modified version of the burst generation rate (BGR) model. Both simulators accurately simulate neutron-induced SE rates (SER's). MBGR actually provides an easier and quicker estimation of neutron-induced SER's than NISES. On the other hand, NISES covers more applications; it simulates neutron-induced charge collection, multiple-bit SE, and [alpha]-induced SE analysis.

1999-06-01

392

Simulation technologies for cosmic ray neutron-induced soft errors: Models and simulation systems  

International Nuclear Information System (INIS)

The authors review two types of simulators for the analysis of cosmic ray neutron-induced soft errors (SE's). One of them is the neutron-induced soft error simulator (NISES). A recently proposed nuclear reaction theory forms the foundation for the nuclear reaction database used in NISES. The other simulator, the simplified simulator MBGR, is based on a modified version of the burst generation rate (BGR) model. Both simulators accurately simulate neutron-induced SE rates (SER's). MBGR actually provides an easier and quicker estimation of neutron-induced SER's than NISES. On the other hand, NISES covers more applications; it simulates neutron-induced charge collection, multiple-bit SE, and #alpha#-induced SE analysis

1999-06-01

393

Removal of scattered thermal neutrons using antiscatter grid  

International Nuclear Information System (INIS)

One of the significant factors of neutron radiographic image degradation is scattering blur from the object. A practical method is described to enhance image quality by eliminating the overlapping of scattered thermal neutrons component from the objects in ETRR-2 neutron radiography facility, using aluminum Gd-coated antiscatter grid. The MCNP code was used to determine the optimum grid dimensions that will reduce the scattered thermal neutrons from the object. An experiment was performed to determine the optimum grid height and irradiation time that gives the best image with acceptable geometric unsharpness. Using the MCNP code it was found that 97% of the scattered neutrons were removed by the grid. The wall dimensions and Gd coating are so small that the facility resolution cannot detect the image pattern superposition on the film.

2006-12-01

394

Real-time imaging for neutron radiography at KURRI  

International Nuclear Information System (INIS)

For neutron radiography (NR), photographic techniques have been mainly used for many years. To observe a dynamic event and to test many samples, the real-time neutron radiography (i.e. neutron television - NTV) system has been introduced at the E-2 experimental tube of the Kyoto University Research Reactor (KUR). The NTV system has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuel, to investigation of moving objects and to neutron computed tomography (NCT). New approaches using some advanced neutron converters, a high sensitive and resolution TV camera and a high performance image processing system are being undertaken for standard indicators, visualization on air-water two-phase flow, NCT and so on. (author).

1987-07-01

395

Proposal of the research complex for the neutron science (The first plan)  

Energy Technology Data Exchange (ETDEWEB)

Japan Atomic Energy Research Institute (JAERI) is developing the world`s strongest spallation neutron source using high power proton accelerator and promoting a neutron science project for comprehensive studies on basic science and nuclear transmutation of high-level radioactive nuclide from nuclear power stations. For this purpose, JAERI organized the Special Taskforce for Neutron Science and OMEGA Project in April 1996 and reorganized it to Center for Neutron Science in April 1997. During this period, various research plans using the spallation neutron source are proposed and facilities necessary for research are studied by mainly research groups of JAERI. This report describes research plans and results of the preliminary conceptual design study on proposed facilities plan. (author)

1999-03-01

396

New thermal neutron imaging facility at the University of Texas reactor  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed at the University of Texas TRIGA reactor. Extensive Monte Carlo design calculations were used to determine optimal design parameters of the neutron collimator system to avoid costly trial and error. Thermal neutron flux determined by gold foil activation is 5 {times} 10{sup 6} n/cm{sup 2}{center_dot}s at the primary imaging location with beam size of 22.5 cm in diameter. The collimation ratio can be varied from 125 to 235. The neutron-to-gamma ratio is 7.8 {times} 10{sup 6} n/cm{sup 2}{center_dot}mR. The facility has been tested for radiography and tomography applications and is now fully operational.

1999-09-01

397

Neutron intensity measurements of BWR spent fuels  

International Nuclear Information System (INIS)

A neutron scanning device was developed in order to obtain accurate neutron intensities of high burn-up BWR fuels. This scanning device was calibrated with a "2"5"2Cf source and used to measure axial distributions of neutron intensities of BWR fuels with various enrichments (2.0%-3.4%) irradiated up to 60 GWd/tU at Fukushima Daini Nuclear Power Station Unit 2(2F-2). The measured neutron intensities were approximated well with power law interpolations on the calculated burn-up values. The neutron intensities calculated by the ORIGEN2-86 code showed good agreements with the measured ones within 20%. (author)

2000-03-01

398

Neutron and gamma-ray penetrations in thick iron  

Energy Technology Data Exchange (ETDEWEB)

Measurements of neutron and gamma-ray penetrations in an iron shield were performed up to a 60-cm depth in a tightly coupled source shield configuration with the fast-neutron reactor YAYOI as a source. Rates of neutron reactions and gamma-ray dose rates in the iron shield were obtained using activation foils and thermoluminescent dosimeters. Analyses of the experiments were made by using the DOT-III code with coupled neutron and gamma-ray cross sections from ENDF/B-IV and POPOP4 libraries. To obtain the source condition for the iron shield analyses, the calculated spectrum was adjusted to the measured reaction rates at the reactor shield boundary. The calculated neutron and gamma-ray distributions in the iron shield show fairly good agreement with the experiments. The effect of difference in Bondarenko-type self-shielding factors on the analyses of the iron shield is also shown.

1980-03-01

399

MCNP study for epithermal neutron irradiation of an isolated liver at the Finnish BNCT facility  

International Nuclear Information System (INIS)

A successful boron neutron capture treatment (BNCT) of a patient with multiple liver metastases has been first given in Italy, by placing the removed organ into the thermal neutron column of the Triga research reactor of the University of Pavia. In Finland, FiR 1 Triga reactor with an epithermal neutron beam well suited for BNCT has been extensively used to irradiate patients with brain tumors such as glioblastoma and recently also head and neck tumors. In this work we have studied by MCNP Monte Carlo simulations, whether it would be beneficial to treat an isolated liver with epithermal neutrons instead of thermal ones. The results show, that the epithermal field penetrates deeper into the liver and creates a build-up distribution of the boron dose. Our results strongly encourage further studying of irradiation arrangement of an isolated liver with epithermal neutron fields.

2004-11-01

400

Group structure and weighting function effects on neutron penetration through thick sodium-iron shields  

Energy Technology Data Exchange (ETDEWEB)

The effects of group structures and weighting functions on neutron penetration through a thick Na-Fe geometry are studied. The recommended broad-group (61-neutron/23-gamma-ray) and few-group (22-neutron/10-gamma-ray) structures are tailored to the sodium and iron resonances, windows, and capture gamma-ray spectra. The best weighting functions are shown to be fine-group fluxes selected from a few key locations in the geometry. These group structures and weighting functions, relative to existing group structures and conventional weighting functions, improve the accuracy of the computed 61-neutron-group Bonner ball responses by up to one hundred percent and of the computed 22-neutron-group results by up to six hundred percent.

1987-01-01

401

Explosives detector  

Energy Technology Data Exchange (ETDEWEB)

An apparatus for non-invasively inspecting an object, such as an item of luggage, for explosives material is described. It comprises a multi-channel thermal neutron inspection system having a plurality of neutron irradiation chambers. Simultaneous operation of several channels increases the maximum system throughput several times. Each chamber has a lithium neutron source which is stimulated to neutron production by a proton beam. Beam switching magnets are energised by pulsing to divert a common proton beam to each source in turn. The initial beam is generated by a radio frequency quadrupole accelerator. The advantages of this system are very low residual source activity and controllable neutron production thereby minimising safety hazards. The irradiation chamber may contain several different gamma ray detectors to identify the elements present in explosives material. In addition, ...

1991-10-02

402

Electronics Personal Dosemeter (EPD-N) Test and Evaluation Report  

Energy Technology Data Exchange (ETDEWEB)

Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological ...

2003-04-08

403

Comparison of the BUGLE-80 and SAILOR libraries for coupled neutron-gamma transport applications  

International Nuclear Information System (INIS)

The coupled neutron-gamma cross section libraries BUGLE-80 and SAILOR are compared, with focus on gamma production and transport and its sensitivity to the thermal component of the neutron flux. In addition, the importance of the prompt versus delayed components of the gamma source is addressed. Although BUGLE-80 shows some discrepancies in the core region, the two libraries demonstrate similar capability in the vicinity of the pressure vessel and beyond. The delayed fission product gammas from the core have little impact on the local gamma fluxes beyond the pressure vessel. Although thermal neutron capture is the dominant component of the gamma source, there is little sensitivity of the gamma source to uncertainties in the thermal neutron cross sections, due to compensating effects which tend to keep the thermal neutron capture rate relatively constant.

404

A Detector for 2-D Neutron Imaging for the Spallation Neutron Source  

Energy Technology Data Exchange (ETDEWEB)

Abstract - We have designed, built, and tested a 2-D pixellated thermal neutron detector. The detector is modeled after the MicroMegas-type structure previously published for collider-type experiments. The detector consists of a 4X4 square array of 1 cm 2 pixels each of which is connected to an individual preamplifier-shaper-data acquisition system. The neutron converter is a 10B film on an aluminum substrate. We describe the construction of the detector and the test results utilizing 252Cf sources in Lucite to thermalize the neutrons.Drift electrode (Aluminum) Converter (10B) 3 mm Conversion gap neutron (-900 V)

2006-07-01

405

Synthesis, characterization and optical properties of a high NIR reflecting yellow inorganic pigment: Mo"6"+ doped Y_2Ce_2O_7 as a cool colorant  

International Nuclear Information System (INIS)

Full text: Pigments possessing the ability to confer high solar reflectance have received considerable attention in recent years. The inorganic class of NIR reflective pigments are mainly metal oxides and are primarily employed in two applications: (i) visual camouflage and (ii) reducing heat build up. More than half of the solar radiation consists of near-infrared radiation (52%), the remaining being 43% visible light and 5% ultraviolet radiation. Over heating due to solar radiation negatively affects comfort in the built environment and contributes substantially to electrical consumption for air conditioning and release of green house gases. A pigment which has strong reflections in the NIR region (780-2500 nm) can be referred to as a 'cool' pigment. However, most of the NIR reflective inorganic pigments particularly yellow (eg. cadmium yellow, lead chromate, chrome titanate yellow etc.) contain toxic metals and hence their consumption is being limited. Replacing ...

2010-11-24

406

Recovery of uranium from aqueous solutions using calcined powders of CaO-Al/sub 2/O/sub 3/-SO/sub 3/ system  

Energy Technology Data Exchange (ETDEWEB)

Aqueous solutions of Al/sub 2/(SO/sub 4/)/sub 3/ (1.05 g/100 ml), AlCl/sub 3/ (0.82 g/100 ml) and Ca(OH)/sub 2/ slurry (0.94 g/50 ml) were mixed in various volume ratios and passed through a filter. White cakes left on the filter consisted mainly of ettringite (6CaO.Al/sub 2/O/sub 3/.3SO/sub 3/.32H/sub 2/O). The cakes were then calcined at various temperatures of 300/sup 0/ -- 1000/sup 0/C for 30 and 60 min and pulverized to 80 -- 200 mesh powders. The adsorption capacity of the powders for U(VI) ions dissolved in aqueous solutions was determined by immersing 0.100 g of their powders in 50 ml of the aqueous solution containing 100 ppm of U(VI) ions mainly in the form of (UO/sub 2/(CO/sub 3/)/sub 3/)/sup 4 -/ for 2 hours. The results obtained were summarized as follows. 1) Among the powders prepared, those of the oxide compositions, 2.9CaO.Al/sub 2/O/sub 3/.1.4SO/sub 3/ and 2.5CaO.Al/sub 2/O/sub 3/.1.2SO/sub 3/, all fired at 500/sup 0/C or 600/sup 0/C showed high adsorption capacity for ...

1981-11-01

407

Synthesis, Characterization and Biological Properties of Anions of Bivalent Transition Metal [Co(II) and Ni(II)] Complexes With Acylhydrazine Derived ONO Donor Schiff Bases.  

Science.gov (United States)

Some acylhydrazine derived ONO donor Schiff bases and their Co(II) and Ni(II) complexes have been prepared having the same metal ion (cation) but different anions. These synthesized metal(II) complexes have been characterized on the basis of their elemental analyses, magnetic moment, molar conductance, and IR and electronic spectral data. All of the Schiff base ligands function as tridentates and the deprotonated enolic form is preferred for coordination. In order to evaluate the effect of anions on the bactericidal activity, these synthesized complexes, in comparison to the uncomplexed Schiff bases have been screened against bacterial species., Escherichia coli, Staphylococcus aureus and Pseudomonas aeruginosa and the results are reported. PMID:18475936

2000-01-01

408

EPR and luminescence studies of Eu(II) magnetically diluted in LiCl-KCl salt  

Energy Technology Data Exchange (ETDEWEB)

High-temperature LiCl-KCl molten salt medium provides an efficient way to produce the paramagnetic Eu(II) ion to be magnetically diluted into a diamagnetic host medium. Eu(II) was formed by a dissolution and an auto-reduction processes in a high-temperature LiCl-KCl eutectic melt at 723 K by using Eu{sub 2}O{sub 3} as a starting material. By using EPR and luminescence spectroscopic method, we studied the nature of the magnetically isolated paramagnetic Eu(II) ion diluted in a LiCl-KCl medium. With the aid of these spectroscopic tools, it was found that stable Eu(II) species was formed spontaneously at 723 K under anaerobic conditions. EPR and luminescence spectroscopy provided detailed information regarding the nature of the europium ion in a molten salt.

2007-12-15

409

EPR and luminescence studies of Eu(II) magnetically diluted in LiCl-KCl salt  

International Nuclear Information System (INIS)

High-temperature LiCl-KCl molten salt medium provides an efficient way to produce the paramagnetic Eu(II) ion to be magnetically diluted into a diamagnetic host medium. Eu(II) was formed by a dissolution and an auto-reduction processes in a high-temperature LiCl-KCl eutectic melt at 723 K by using Eu_2O_3 as a starting material. By using EPR and luminescence spectroscopic method, we studied the nature of the magnetically isolated paramagnetic Eu(II) ion diluted in a LiCl-KCl medium. With the aid of these spectroscopic tools, it was found that stable Eu(II) species was formed spontaneously at 723 K under anaerobic conditions. EPR and luminescence spectroscopy provided detailed information regarding the nature of the europium ion in a molten salt.

2007-12-01

410

EPR and luminescence studies of Eu(II) magnetically diluted in LiCl-KCl salt  

British Library Electronic Table of Contents (United Kingdom)

High-temperature LiCl-KCl molten salt medium provides an efficient way to produce the paramagnetic Eu(II) ion to be magnetically diluted into a diamagnetic host medium. Eu(II) was formed by a dissolution and an auto-reduction processes in a high-temperature LiCl-KCl eutectic melt at 723K by using Eu2O3 as a starting material. By using EPR and luminescence spectroscopic method, we studied the nature of the magnetically isolated paramagnetic Eu(II) ion diluted in a LiCl-KCl medium. With the aid of these spectroscopic tools, it was found that stable Eu(II) species was formed spontaneously at 723K under anaerobic conditions. EPR and luminescence spectroscopy provided detailed information regarding the nature of the europium ion in a molten salt.

2007-01-01

411

Chromosomal localization and structure of the human type II IMP dehydrogenase gene  

Energy Technology Data Exchange (ETDEWEB)

We determined the chromosomal localization and structure of the gene encoding human type II inosine 5{prime}-monophosphate dehydrogenase (IMPDH, EC 1.1.1.205), an enzyme associated with cellular proliferation, malignant transformation, and differentiation. Using polymerase chain reaction (PCR) primers specific for type II IMPDH, we screened a panel of human-Chinese hamster cell somatic hybrids and a separate deletion panel of chromosome 3 hybrids and localized the gene to 3p21.1{yields}p24.2. Two overlapping yeast artificial chromosome clones containing the full gene for type II IMPDH were isolated and a physical map of 117 kb of human genomic DNA in this region of chromosome 3 was constructed. The gene for type II IMPDH was localized and oriented on this map and found to span no more than 12.5 kb.

1994-05-01

412

A comparison of thermal maturity parameters between freely extracted hydrocarbons (Bitumen I) and a second extract (Bitumen II) from within the kerogen matrix of Permian and Triassic sedimentary rocks  

British Library Electronic Table of Contents (United Kingdom)

In this study we compared various maturity dependent aromatic, steroid and triterpenoid hydrocarbon ratios in bitumens that are freely extractable from sedimentary rocks (Bitumen I) with those in second extracts that comprised hydrocarbons closely associated with the kerogen/mineral matrix (Bitumen II). Bitumen II was released through kerogen isolation and demineralisation using HCl and HF/H3BO3. The samples studied, although of similar age, come from different localities. They represent a range of facies and two kerogen types (II and III), and all were deposited under marine conditions. The results show that the more stable b isomers of methylnaphthalene (MN) and methylphenanthrene (MP) are relatively more abundant in Bitumen II. The difference between the methylnaphthalene ratio (MNR) of...

2010-01-01

413

High-efficiency Resonant rf Spin Rotator with Broad Phase Space Acceptance for Pulsed Polarized Cold Neutron Beams  

Energy Technology Data Exchange (ETDEWEB)

High precision fundamental neutron physics experiments have been proposed for the intense pulsed spallation neutron beams at JSNS, LANSCE, and SNS to test the standard model and search for new physics. Certain systematic effects in some of these experiments have to be controlled at the few ppb level. The NPD Gamma experiment, a search for the small parity-violating {gamma}-ray asymmetry A{sub Y} in polarized cold neutron capture on parahydrogen, is one example. For the NPD Gamma experiment we developed a radio-frequency resonant spin rotator to reverse the neutron polarization in a 9.5 cm x 9.5 cm pulsed cold neutron beam with high efficiency over a broad cold neutron energy range. The effect of the spin reversal by the rotator on the neutron beam phase space is compared qualitatively to rf neutron spin flippers based on ...

2008-08-01

414

Analysis of coupled neutron-gamma radiations, applied to shieldings in multigroup albedo method; Analise das radiacoes neutron e gama acopladas, aplicada a blindagem com varias camadas pelo metodo multigrupo do albedo  

Energy Technology Data Exchange (ETDEWEB)

The principal mathematical tools frequently available for calculations in Nuclear Engineering, including coupled neutron-gamma radiations shielding problems, involve the full Transport Theory or the Monte Carlo techniques. The Multigroup Albedo Method applied to shieldings is characterized by following the radiations through distinct layers of materials, allowing the determination of the neutron and gamma fractions reflected from, transmitted through and absorbed in the irradiated media when a neutronic stream hits the first layer of material, independently of flux calculations. Then, the method is a complementary tool of great didactic value due to its clarity and simplicity in solving neutron and/or gamma shielding problems. The outstanding results achieved in previous works motivated the elaboration and the development of this study that is presented in this dissertation. The radiation balance ...

2002-07-01

415

Biosorption of Cd(II), Ni(II) and Pb(II) from aqueous solution by dried biomass of aspergillus niger: application of response surface methodology to the optimization of process parameters  

Energy Technology Data Exchange (ETDEWEB)

In this study, the biosorption of Cd(II), Ni(II) and Pb(II) on Aspergillus niger in a batch system was investigated, and optimal condition determined by means of central composite design (CCD) under response surface methodology (RSM). Biomass inactivated by heat and pretreated by alkali solution was used in the determination of optimal conditions. The effect of initial solution pH, biomass dose and initial ion concentration on the removal efficiency of metal ions by A. niger was optimized using a design of experiment (DOE) method. Experimental results indicated that the optimal conditions for biosorption were 5.22 g/L, 89.93 mg/L and 6.01 for biomass dose, initial ion concentration and solution pH, respectively. Enhancement of metal biosorption capacity of the dried biomass by pretreatment with sodium hydroxide was observed. Maximal removal efficiencies for Cd(II), Ni(III) and ...

2009-10-15

416

Radiation reduction of dicarboxylatoimidazole platinum(II) complexes in the water-methanol system  

Energy Technology Data Exchange (ETDEWEB)

The radiation reduction of bis(1-ethylimidazole)tartratoplatinum(II) (EITPt(II)) complexes in methanol-water solution have been examined. The yields of Pt(I) depend on the presence of O{sub 2} in solutions as well as the dose applied. The rate constants of e{sub s}{sup -} scavenging by EITPt(II) and cis(diammine-1,1-cyclobutanedicarboxylato) platinum(II) (CBDCAPt(II)) have been determined by pulse radiolysis to be equal to 5.4 x 10{sup 9} and 6.4 x 10{sup 9} M{sup -1} s{sup -1}, respectively. The efficiencies of e{sub t}{sup -} scavenging by EITPt(II) and the rate of e{sub t}{sup -} photobleaching have also been determined in LiCl : H{sub 2}O : CH{sub 3}OH and MgCl{sub 2} : H{sub 2}O : CH{sub 3}OH glasses, respectively. (author).

1997-10-01

417

beta- and gamma-decay studies of neutron-rich chromium, manganese, cobalt and nickel isotopes including the new isotopes $^{60}$Cr and $^{60g}$Mn  

CERN Document Server

beta- and gamma-decay studies of neutron-rich chromium, manganese, cobalt and nickel isotopes including the new isotopes $^{60}$Cr and $^{60g}$Mn

1987-01-01

418

The Neutron Radiography Reactor (NRAD)  

Science.gov (United States)

The Neutron Radiography Reactor (NRAD) operated by Argonne National Laboratory is described in this paper. NRAD was designed to allow radiography of highly absorbing reactor fuel assemblies in the vertical position on the routine basis. 7 figs.

1990-01-01

419

Revised neutron dosimetry results for the MOTA-2A experiment in FFTF  

Energy Technology Data Exchange (ETDEWEB)

Revised neutron fluence and damage values are reported for the MOTA-2A experiment in the Fast Flux Test Facility (FFTF). This revision corrects an error with processing of the {sup 235}U(n,f) reaction. Net corrections are on the order of 5%.

1994-09-01

420

Real-time neutron beam monitor  

Energy Technology Data Exchange (ETDEWEB)

An array of multiwire proportional counters has been employed to image, in 'real-time', a collimated neutron beam produced at an electron linac facility. Test results are presented, along with a discussion of the advantages of this technique.

1983-06-15

421

Polymer-cushioned bilayers. I. A structural study of various preparation methods using neutron reflectometry.  

UK PubMed Central (United Kingdom)

This neutron reflectometry study evaluates the structures resulting from different methods of preparing polymer-cushioned lipid bilayers. Four different techniques to deposit a dimyristoylphosphatidylcholine...Full Text Available

1999-09-01

422

Phonon density of states in V_3Si  

International Nuclear Information System (INIS)

The observation by inelastic neutron scattering techniques of a high energy peak in the phonon spectrum (14 THz) of V_3Si is reported, and is attributed to a peak in the phonon density of states due to vanadium motions by the incoherent inelastic neutron scattering process.

1988-12-01

423

Once more: gravity is not an entropic force  

CERN Document Server

We argue that neutron interference experiments and experiments on gravitational bound states of neutron unambiguously disprove entropic origin of gravitation. The criticism expressed in a recent paper [arXiv:1104.4650] concerning our arguments against entropic gravity is shown to be invalid.

2011-01-01

424

Nuclear data sheets update for A = 101  

Science.gov (United States)

The 1985 evaluation of A = 1-1 (85B1114) has been revised. Experimental information is presented from the neutron-rich {sup 101}Sr to the neutron-deficient {sup 101}In.

1991-06-01

425

Nuclear data sheets update for A = 101  

International Nuclear Information System (INIS)

The 1985 evaluation of A = 1-1 (85B1114) has been revised. Experimental information is presented from the neutron-rich "1"0"1Sr to the neutron-deficient "1"0"1In.

426

Neutron Star Evolution with Internal Energy h'q/>a Dissipation by ...  

Science.gov (United States)

Neutron Star Evolution with Internal Energy h'q/>a. Dissipation by Vortex Creep. N. Shibazaki and F. K. Lamb. University of Illinois at Urbana-Champaign ...

427

Mott-Schwinger Scattering of Polarized Low Energy Neutrons up to Thermal Energies  

Energy Technology Data Exchange (ETDEWEB)

The availability of new, high-intensity, cold and thermal neutron sources has opened the possibility of performing high-precision fundamental neutron physics experiments, including measurements that study the hadronic weak interaction and standard model test measurements, using neutron decay. The observables in these experiments are usually correlated with the direction of neutron polarization and are often very small (10 8 10 6). Mott-Schwinger scattering of polarized neutrons can produce spin-dependent shifts in beam centroids, which has the potential to produce significant systematic effects for these types of experiments. An accurate calculation of this process for neutral atoms and basic molecules has not been carried out for low neutron energies. In this work, we derive a general expression for the electromagnetic (Mott-Schwinger) contributions to the ...

2008-10-01

428

Modeling of Fission Neutrons as a Signature for Detection of Highly Enriched Uranium  

Energy Technology Data Exchange (ETDEWEB)

We present the results of modeling intended to evaluate the feasibility of using neutrons from induced fission in highly enriched uranium (HEU) as a means of detecting clandestine HEU, even when it is embedded in absorbing surroundings, such as commercial cargo. We characterized radiation from induced fission in HEU, which consisted of delayed neutrons at all energies and prompt neutrons at energies above a threshold. We found that for the candidate detector and for the conditions we considered, a distinctive HEU signature should be detectable, given sufficient detector size, and should be robust over a range of cargo content. In the modeled scenario, an intense neutron source was used to induce fissions in a spherical shell of HEU. To absorb, scatter, and moderate the neutrons, we place one layer of simulated cargo between the source and target and an identical layer between the ...

2004-03-09

430

Measurement of cosmic ray neutron spectrum at sea level  

International Nuclear Information System (INIS)

The cosmic ray neutron spectrum at sea level has been measured by the method of pulse shape discrimination in anthracene scintillator. The exponent of the differential spectrum was found to be 2.2+-0.1. (Auth.).

431

Magnetic fields of x-ray pulsars  

Energy Technology Data Exchange (ETDEWEB)

An analytic model of magnetic torques applied to an accreting neutron star is employed to evaluate the magnetic dipole moments of x-ray pulsars. A new type of close binary system containing a neutron star is suggested.

1982-09-01

432

Fluid flow visualization with neutron radiography  

International Nuclear Information System (INIS)

A technique was developed that permits fluid flow to be visualized even where the flow is completely shrouded by metal. The technique employs real-time neutron radiography, which is similar to x-ray radiography except a collimated beam of neutrons is used. Various combinations of neutron-opaque tracer materials were tested with neutron-transparent fluid. Neutron opaque tracers, such as solid particles, fluid droplets, and streaklines were imaged through metal walls as they convected in neutron-transparent ambient fluid. Visualization of bubbles/voids were evaluated for possible future applications. Surface-flow patterns were also imaged by using neutron-opaque tufts. These techniques were evaluated for image contrast, resolution, and the ability to accurately track fluid flow fields. The techniques were also modeled to optimize contrast in ...

1764-01-01

433

First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry  

Energy Technology Data Exchange (ETDEWEB)

A prototype detector based on the inclined boron layer principle is introduced. For typical measurement conditions at the Liquids Reflectometer at the Spallation Neutron Source, its count rate capability is shown to be superior to that of the current detector by nearly two orders of magnitude.

2010-01-01

434

First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry  

Energy Technology Data Exchange (ETDEWEB)

A prototype detector based on the inclined absorber layer principle is introduced. For the Liquids Reflectometer at the Spallation Neutron Source, it is shown to be a significant improvement over its current detector, which imposes an instantaneous count rate limitation of 50 kcps.

2008-10-01

435

Examples of degenerated matter in astrophysics: white dwarf and neutron stars  

Energy Technology Data Exchange (ETDEWEB)

Main features of star evolution are recalled. Then the general structure of white dwarf stars is examined. From the equation of state of an electron gas completely degenerated are deduced: mechanical equilibrium, Viriel theorem, mass-radius relationship and Chandrasekhar limit. These results are applied to neutron stars.

1982-06-01

436

Development of real time personal neutron dosimeter with two silicon detectors  

Energy Technology Data Exchange (ETDEWEB)

The personal neutron dosimetry becomes more important with the increasing use of nuclear and accelerator facilities. The solid state track detector, film badge and thermo-luminescent dosimeter have widely been used as passive-type personal neutron dosimeters, but the real-time neutron dosimeter is strongly needed. A real time personal dosimeter which could give neutron dose equivalent over wide energy range from thermal to 10 odd MeV by using two neutron sensors has been developed by our group. For practical commercial product, some changes from these prototype sensors have recently been done by Fuji Electric Co. Ltd. The purpose of this work is the final performance test of the dosimeter just before sale. We checked again about the sensitivity in the monoenergetic neutron field from 8 keV to 15 MeV and in the neutron fields around a few ...

1997-07-01

439

Anisotropy of fission of /sup 242//sup m/Am by fast neutrons  

Energy Technology Data Exchange (ETDEWEB)

Careful measurements do not confirm an anomalous anisotropy in the angular distribution of fission fragments from the fast neutron fission of Americium 242. The energy range covered was 1.60-3.15 MeV. (AIP)

1985-10-01

440

A real-time neutron beam monitor  

International Nuclear Information System (INIS)

An array of multiwire proportional counters has been employed to image, in 'real-time', a collimated neutron beam produced at an electron linac facility. Test results are presented, along with a discussion of the advantages of this technique. (orig.).

1983-06-01

441

X-ray dosimetry of TlGaSe_2 single crystals  

International Nuclear Information System (INIS)

TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. X-ray conductivity coefficients K_#sigma# characterising X-ray sensitivity of investigated crystals are determined ...

442

Neutron beam experiments using nuclear research reactors: honoring the retirement of professor Bernard W. Wehring -II. 4. Accurate Characterization of the Shape of the HPGe Detector Peak Efficiency Curve for Application in PGNAA  

International Nuclear Information System (INIS)

In various situations, measurements in prompt gamma neutron activation analysis (PGNAA) are performed to determine the amount of an elemental impurity relative to that of a major constituent of the matrix. An example of this is the measurement of hydrogen concentration in a metallic matrix. In all such cases, a major contributor to the uncertainty in the measurement is the uncertainty in the ratio of the high-purity germanium (HPGe) detector full-energy peak efficiency for the gamma-ray lines of interest (i.e., impurity and matrix gammas). Usually, the ratio is derived from the relative peak efficiency curve, which is determined using isotopic standards that emit multiple gamma ray lines (e.g., "1"5"2Eu) in the energy range <3000 keV, or using prompt gamma radionuclides (e.g., "1"4N, "3"5Cl) in the energy range >3000 keV. In either case, the uncertainty in the ratio of the peak efficiency values derived from such measurements will be on the order of a few ...

2001-06-17

443

Transverse Imaging of the Proton in Exclusive Diffractive pp Scattering  

Energy Technology Data Exchange (ETDEWEB)

In a forthcoming paper we describe a new approach to rapidity gap survival (RGS) in the production of high-mass systems (H = dijet, Higgs, etc.) in exclusive double-gap diffractive pp scattering, pp -> p + H + p. It is based on the idea that hard and soft interactions are approximately independent (QCD factorization), and allows us to calculate the RGS probability in a model-independent way in terms of the gluon generalized parton distributions (GPDs) in the colliding protons and the pp elastic scattering amplitude. Here we focus on the transverse momentum dependence of the cross section. By measuring the ''diffraction pattern'', one can perform detailed tests of the interplay of hard and soft interactions, and even extract information about the gluon GPD in the proton from the data.

2006-04-20

444

Microstructure analysis of nanocrystalline powders by X-ray diffraction  

International Nuclear Information System (INIS)

The use of X-ray diffraction line profile analysis for the study of nanocrystalline powders is described. The fundamentals of the theory are presented in terms of crystallite/domain size, size distribution, lattice distortion, dislocations density and stacking faults. Line profile parameters and the methods of pattern fitting introduced to overcome the diffraction-line overlap problem are discussed. The approaches based of the integral breadth of the measured line profiles and the Fourier method are discussed. In addition, simplified approaches are also commented. Representative examples are selected to illustrate various cases of microstructure, such as nanomaterials with strain-free spherical nano crystallites, strain-free crystallites with anisotropic crystallite shape, anisotropic crystallites with microstrains and spherical crystallites with dislocation densities and crystallite size distributions. (author)

2001-09-23

445

Identification of fatigue damage in cortical bone by diffraction enhanced imaging  

International Nuclear Information System (INIS)

In an effort to explore Diffraction Enhanced Imaging of bone tissue, experiments were performed to determine if it was possible to use Diffraction Enhanced Imaging to detect microdamage in bovine cortical bone. Measurements were made at the National Synchrotron Light Source where pre- and post-fatigue rocking curve widths of the bone were studied. The rocking curve widths were then compared. Since no consistent pattern of narrowing or broadening of the rocking curve emerged, it is likely that the ultra-small-angle X-ray scattering present in the bone overshadowed any additional changes to rocking curve caused by microdamage of the bone. Larger bone structures were able to be visualized which suggests that microdamage may be visualized with a higher resolution detector.

2005-08-11

446

Gauging film thickness: A comparison of an x-ray diffraction technique with Rutherford backscattering spectrometry  

Energy Technology Data Exchange (ETDEWEB)

An x-ray diffraction technique for determining thin-film thickness is presented which should prove to be a valuable alternative to the array of spectroscopies (Rutherford backscattering spectrometry, Auger electron spectroscopy, etc.) currently favored for these measurements. Some of the virtues of this x-ray diffraction approach are its nondestructive nature, fast data acquisition rate (enabling in situ observations), thickness resolution better than 5 nm, and conventional equipment requirements. Results are shown for Pd/sub 2/Si thin films grown during isothermal annealing of Pd coatings (100 nm) on Si at 200 /sup 0/C for various amounts of time. A comparison of these x-ray measurements with Rutherford backscattering spectrometry data taken from the same specimens is used to demonstrate the validity of the x-ray technique.

1985-01-15

447

Diffusion examined by diffraction  

Science.gov (United States)

X-ray diffraction offers a unique combination of advantages for kinetic study which include the non-destructive nature of the measurement, the use of bulk crystals, and the convenience of the experimental arrangements. These attributes and the availability of position-sensitive detectors and high-flux synchrotron radiation sources make this technique most useful for in situ, dynamical investigations. When using diffraction techniques to determine a diffusion coefficient, the principle of analysis entails a scattering theory and a kinetic model. The former allows the kinetic parameter(s) to be extracted from measured intensity, while the latter relates the kinetic parameter(s) to the diffusion coefficient(s). Three examples are demonstrated: (1) Palladium Silicide (Pd{sub 2}Si) Layer Growth on Silicon, (2) Decomposition of an Ni-12.5at%Si Superalloy, and (3) Short-range Ordering in Cu-Au Solid Solutions.

448

Diffraction applications using the energy dispersive beamline X6A at the National Synchrotron Light Source  

Energy Technology Data Exchange (ETDEWEB)

The energy dispersive beamline X6A at the National Synchrotron Light Source employs a curved crystal monochromator (polychromator) which focuses a range ([similar to]1 keV) of x-ray energies into a narrow (100--120 [mu]m) line image. Although this beamline was constructed primarily for time-dependent EXAFS experiments, we have begun to explore the use of this instrument for energy dispersive diffraction experiments with different types of sample including macromolecular crystals. The tunability ([ital E]=6.5 to 21 keV) and flexibility ([Delta][ital E]=100--1000 eV) of the instrument makes the beamline ideal as a test bed for the application of polychromatic single-crystal diffraction techniques to different chemical or biological materials.

1995-02-01

450

WWW.NMDB.EU: The real-time neutron-monitor data-bank  

International Nuclear Information System (INIS)

German 2009 [1 p.] Germany Steigies, Christian IEAP, Christian-

2009-04-02

451

UNFBENJ: on-line, real-time neutron spectrum unfolding for Benjamin detectors  

International Nuclear Information System (INIS)

(Jun 1978). United States Miller, H. Univ. of Missouri, Columbia Peterman,

1978-06-18

452

Three-quasiparticle states in "1"7"7Ta  

International Nuclear Information System (INIS)

... transitions lutetium 175 target mev range 10-100 multipolarity neutrons parity

453

The structure of the transitional N=59 nucleus "1"0"1Mo  

International Nuclear Information System (INIS)

... fermions interacting boson model molybdenum 101 neutron-rich isotopes

1987-03-23

455
456

Scintillation converter screen investigation for real-time neutron radiography  

International Nuclear Information System (INIS)

(1980). United States Panhuise, VE Bull, SR Seydel, JA Univ of Missouri-

1980-11-21

457

Real-time neutron radiography observations of aerosol filtration  

International Nuclear Information System (INIS)

(1984). United States Brenizer, JS McRae, DD Sulcoski, MF University

1984-11-11

458

Real-time neutron radiography at the Georgia Tech Research Reactor  

International Nuclear Information System (INIS)

(Jun 1982). United States Davis, MV Berger, H. Patricelli, F. Georgia Institute

1982-06-11

459

Radiation hardness of plastic scintillating fiber  

International Nuclear Information System (INIS)

We report on measurements of radiation hardness of the plastic scintillating fiber SCSF-81. Fibers were irradiated with "6"0Co #gamma#-rays and fast neutrons up to 105 Gy and up to 5 x 1013 n/cm"2, respectively. Deterioration of the attenuation length of the scintillating fiber was studied. Some significant deterioration was observed at the integrated dose of about 1 x 103 Gy and at the integrated neutron flux (neutron fluence) of about 1 x 1012 n/cm"2 for #gamma#-ray and neutron irradiation, respectively. (author).

460

RXTE Catches Morphing Magnetar  

Science.gov (United States)

This exciting new development in neutron star evolution was presented at the Winter 2004 AAS Meeting in Atlantia,Georgia. ...

461

Quantitative density measurements from a real-time neutron radiography system  

Energy Technology Data Exchange (ETDEWEB)

An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.

1986-01-01

462

Quantitative density measurements from a real-time neutron radiography system  

International Nuclear Information System (INIS)

An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.

1986-11-16

463

Precise Measurement of the Neutron Magnetic Form Factor G{sub M}{sup n} in the Few-GeV{sup 2} Region  

Science.gov (United States)

The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q{sup 2}=1.0-4.8 GeV{sup 2} with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.

2009-05-15

464

Precise Measurement of the Neutron Magnetic Form Factor GMn in the Few-GeV2 Region  

International Nuclear Information System (INIS)

The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q2=1.0-4.8 GeV2 with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.

2009-05-15

465

Nuclear moments and changes in rms-radii of neutron-deficient silver isotopes  

International Nuclear Information System (INIS)

... nuclear electric moments nuclear magnetic moments nuclear radii quadrupole

1987-03-23

467

Neutron resonances in /sup 100/Mo and valence neutron capture  

Science.gov (United States)

Neutron resonance interactions with /sup 100/Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% /sup 100/Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture ..gamma..-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.

1979-07-01

468

Neutron radiography with the cyclotron, 5  

International Nuclear Information System (INIS)

Reliable facility of cyclotron-based real time neutron radiography system has been developed and applied to some industrial components. The equipment for neutron fluoroscopy is based on a sub-compact cyclotron and a LiF/ZnS (Ag) fluorescent screen viewed by a silicon intensifier target TV camera. The real time image is monitored on a CRT, recorded with a standard video recorder and processed by a digital image processor. The effectiveness of our real time neutron radiograph has been demonstrated to be applicable to not only the dynamic observation but also the magnifying and stereoscopic observation of fluoroscopic images. (author).

1987-01-01

470

Neutron leakage benchmarks for water moderators  

Energy Technology Data Exchange (ETDEWEB)

Fission reaction rates for four nuclides were measured in the leakage spectrum outside spherical water moderators of various radii surrounding a {sup 252}Cf neutron source. Using the MCNP transport code, matching calculations were made with highly detailed modeling of the measurement apparatus. The calculations predicted significantly higher leakage of neutrons in the epicadmium energy range than was found in the measurements. A discrepancy of the same sign but weaker magnitude was found for thermal neutrons. These discrepancies may be relevant to problems with criticality calculations in special cases.

1994-12-31

472

Multigroup transfer matrices for charged-particle and neutron-induced reactions Part III: Energy conservation and local deposition  

Energy Technology Data Exchange (ETDEWEB)

Energy conservation and local energy deposition are investigated in the context of coupled-particle (i.e., neutrons, gamma rays, and charged particles) transport analysis. For charged particles, the concept of group splitting the 1 = 0 transfer matrix to ensure both particle and energy conservation is introduced. Although these procedures are more complex than those found in the usual neutron or coupled-neutron gamma-ray problem, they yield a consistent approach for the calculation of local energy deposition.

1983-11-01

473

Multigroup transfer matrices for charged-particle and neutron-induced reactions Part III: Energy conservation and local deposition  

International Nuclear Information System (INIS)

Energy conservation and local energy deposition are investigated in the context of coupled-particle (i.e., neutrons, gamma rays, and charged particles) transport analysis. For charged particles, the concept of group splitting the 1 = 0 transfer matrix to ensure both particle and energy conservation is introduced. Although these procedures are more complex than those found in the usual neutron or coupled-neutron gamma-ray problem, they yield a consistent approach for the calculation of local energy deposition.

1983-01-01

475

Kaon properties in (proto-)neutron star matter  

British Library Electronic Table of Contents (United Kingdom)

Abstract. The modification of kaon and antikaon properties in the interior of (proto-)neutron stars is investigated using a chiral SU(3) model. The parameters of the model are fitted to nuclear-matter saturation properties, baryon octet vacuum masses, hyperon optical potentials and low-energy kaon-nucleon scattering lengths. We study the kaon/antikaon medium modification and explore the possibility of antikaon condensation in (proto-)neutron star matter at zero as well as finite temperature/entropy and neutrino content. The effect of hyperons on kaon and antikaon optical potentials is also investigated at different stages of the neutron star evolution.

2010-01-01

476

Implantation of an electronic system for real time neutron graphic images acquisition at the IPEN/CNEN Argonaut reactor  

International Nuclear Information System (INIS)

The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)

2004-04-01

477

INEEL Advanced Radiotherapy Research Program Annual Report 2001  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.

2002-04-01

478

INEEL Advanced Radiotherapy Research Program Annual Report 2001  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.

2002-04-30

484

Characteristics of cosmic ray pole-equator anisotropy derived from spherical harmonic analysis of neutron monitor data  

International Nuclear Information System (INIS)

The spherical harmonic analysis of cosmic ray neutron data from the worldwide network neutron monitor stations during the years 1966 to 1969 was carried out. The second zonal harmonic component obtained from the analysis corresponds to the Pole-Equator anisotropy of the cosmic ray neutron intensity. Such an anisotropy makes a semiannual variation. In addition to this, it is shown that the Pole-Equator anisotropy makes a variation depending on the interplanetary magnetic field (IMF) sector polarities around the passages of the IMF sector boundary. A mechanism to interpret these results is also discussed.

1985-08-01

485

COMPUTERIZED CONTROL OF BLAST FURNACE COKE ...  

Science.gov (United States)

... Title : COMPUTERIZED CONTROL OF BLAST FURNACE COKE-WEIGHING OPERATIONS USING NEUTRON MOISUTRE GAUGES. ...

1974-09-01

486

Basic Design Report of DC-TOF Inelastic Neutron Spectrometer  

Energy Technology Data Exchange (ETDEWEB)

We made Basic designs of neutron guide, choppers, and detectors in order to optimize the design parameters of DC-TOF to be built in the HANARO Cold Neutron Guide Hall. In addition, we calculated the expected performance of DC-TOF using Monte Carlo simulations and evaluated the properties of neutron beam. Based on the results we obtained, we have compared the expected performance of the DC-TOF with those of existing instruments overseas. In conclusion, we believe that we will be able to construct the DC-TOF at HANARO as one of the best instruments of its kinds and it will become an invaluable instrument to researchers in the related field.

2006-04-15

487

Activation method for determination of Pb, La, Zr and Ti macrocomponents in lead-lanthanum zirconate-titanate materials on a neutron generator  

International Nuclear Information System (INIS)

Instrumental neutron activation analysis is used for simultaneously determination of macrocomponents in ferroelectric materials LLZT. Pb, Zr, Ti have been determined by "2"0"3Pb, "8"9Zr and "4"8Sc nuclides created by fast neutron (14.5 MeV) activation. Application of paraffine as neutron moderator and reflector allows to simultaneously determine lanthanum by "1"4"0La nuclide. It has been shown that zirconium, titanium and lanthanum can be determined with the accuracy of #+-#0.1 mas. % and lead - #+-#0.7 mas. %.

488

A new type active personal dosemeter with a solid state detector  

International Nuclear Information System (INIS)

We have developed a new type personal dosemeter by using a B-10 doped silicon p-n junction detector with a polyethylene radiator and a polyethylene moderator. The purpose of this study was to develop a real time neutron dosemeter with a nearly flat response in the energy range from thermal to 15 MeV and low angular dependence to the incident neutron direction. The neutron response of the dosemeter was obtained with the Monte Carlo calculation and the monoenergetic neutron experiment in a free air field and also under a condition attached on a phantom.

1988-04-01

489
490

The influence of asymmetry on a magnetized proto-neutron star  

Energy Technology Data Exchange (ETDEWEB)

Using the Relativistic Mean Field Theory (RMF) it is shown that different proton fraction which is directly connected with the neutron excess and with the asymmetry of the system affects proto-neutron stars parameters and changes their composition. The obtained form of the equation of state allows to construct the mass-radius relations and shows that the increasing asymmetry creates more compact stars. The inclusion of {delta} meson together with nonlinear vector meson interaction terms and magnetic field make this effect even stronger.

2003-03-24

491

The hyperon neutron star mean-field model  

Energy Technology Data Exchange (ETDEWEB)

The properties of strange neutron stars have been studied with the use of the parameter sets stemming from the effective field theory. The impact of the strength of hyperon interactions on neutron star masses has been analyzed. The inclusion of additional nonlinear meson interaction terms together with the strong hyperon-hyperon interaction leads to the existence of additional stable stellar configurations. (authors)

2007-05-15

492

Status of the Oak Ridge spallation neutron source (ORSNS) project  

International Nuclear Information System (INIS)

The current status and future plans of the Ok Ridge Spallation Neutron Source (ORSNS) are reviewed. The ORSNS is a new project initiated by the U.S. Department of Energy (DOE) beginning October 1, 1995, to prepare the conceptual for a new spallation neutron source. (author) 2 refs.

1995-11-01

493

Spectrum measurement of neutrons from 40 MeV alpha particle bombardment of tantalum  

International Nuclear Information System (INIS)

The energy distribution of neutrons generated due to bombardment of 40 MeV alpha particles on thick elemental tantalum is measured using threshold activation detectors. A method of unfolding the neutron spectrum from the activation data based on information-entropy weighted average solution is described. The present unfolding method does not require 'a priori' information about the shape of the solution spectrum. 16 refs. (author).

494

Improving airport explosives detection  

Energy Technology Data Exchange (ETDEWEB)

ORNL has developed the technology to detect hidden explosives in luggage using X ray and neutron detection devices. The Federal Aviation Administration has ordered the airlines to buy and install Thermal Neutron Analysis (TNA) units. The combined pulsed-neutron and X-ray interrogation inspection (CPNX) system developed at ORNL uses less radioactive materials as well as being more sensitive to weapons, electronic devices and plastic explosives.

1990-01-01

495

Gamma-ray spectra from neutron capture on /sup 87/Sr  

Energy Technology Data Exchange (ETDEWEB)

The gamma-ray spectrum following neutron capture on /sup 87/Sr was measured at 3 neutron energies: E/sub n/ = thermal, 2 keV, and 24 keV. Gamma rays were detected in a three-crystal Ge(Li)-NaI-NaI pair spectrometer. Gamma-ray intensities deduced from these spectra by spectral unfolding are presented.

1981-07-01

496

Facility for studying photon-neutron reactions under a beam of braking radiation  

International Nuclear Information System (INIS)

A facility for studying photon-neutron reactions under a braking #gamma#-beam with an energy of up to 26 MeV from a betratron includes Saratov-2, SM-4A, and IBM AT-386 microcomputers. Neutron detectors, pulsed braking radiation dosimeters, and the devices to control the betatron energy are described.

497

Applications of Bonner sphere detectors in neutron field dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)

1983-09-01