The isotherms, kinetics and thermodynamics of Cd(II), Zn(II) and Pb(II) biosorption by Penicillium simplicissimum were investigated in a batch system. The effects of pH, initial metal ions concentration, biomass dose, contact time, temperature and co-ions on the biosorption were studied. Adsorption data were well described by both the Redlich-Peterson and Langmuir model. Chemical ion-exchange was found to be an important process based on free energy value from Dubini-Radushkevich isotherm for all metal ions. The results of the kinetic studies of all metal ions at different temperature showed that the rate of adsorption followed the pseudo second-order kinetics well. The thermodynamics constants {delta}G{sup o}, {delta}H{sup o} and {delta}S{sup o} of the adsorption process showed that biosorption of Cd(II), Zn(II) and Pb(II) ions on ...
PurposeRTOG protocol 95-17 was a phase I/II trial to evaluate multi-catheter brachytherapy as the sole method of adjuvant breast radiotherapy for stage I/II breast...Full Text Available
In this study, the biosorption of Cd(II), Ni(II) and Pb(II) on Aspergillus niger in a batch system was investigated, and optimal condition determined by means of central composite design (CCD) under response surface methodology (RSM). Biomass inactivated by heat and pretreated by alkali solution was used in the determination of optimal conditions. The effect of initial solution pH, biomass dose and initial ion concentration on the removal efficiency of metal ions by A. niger was optimized using a design of experiment (DOE) method. Experimental results indicated that the optimal conditions for biosorption were 5.22 g/L, 89.93 mg/L and 6.01 for biomass dose, initial ion concentration and solution pH, respectively. Enhancement of metal biosorption capacity of the dried biomass by pretreatment with sodium hydroxide was observed. Maximal removal efficiencies for ...
The radiation reduction of bis(1-ethylimidazole)tartratoplatinum(II) (EITPt(II)) complexes in methanol-water solution have been examined. The yields of Pt(I) depend on the presence of O{sub 2} in solutions as well as the dose applied. The rate constants of e{sub s}{sup -} scavenging by EITPt(II) and cis(diammine-1,1-cyclobutanedicarboxylato) platinum(II) (CBDCAPt(II)) have been determined by pulse radiolysis to be equal to 5.4 x 10{sup 9} and 6.4 x 10{sup 9} M{sup -1} s{sup -1}, respectively. The efficiencies of e{sub t}{sup -} scavenging by EITPt(II) and the rate of e{sub t}{sup -} photobleaching have also been determined in LiCl : H{sub 2}O : CH{sub 3}OH and MgCl{sub 2} : H{sub 2}O : CH{sub 3}OH glasses, respectively. (author).
This objective of this work was to summarize the main results obtained in previous papers related to the adsorbent-adsorbate interactions involved in the adsorption of naphthalenesulphonic acids and heavy metals (Cd(II) or Hg(II)) by modified activated carbons. The adsorption of organic compounds (1-naphthalenesulphonic acid, 1,5-naphthalenedisulphonic acid and 1,3,6-naphthalenetrisulphonic acid) and inorganic species (Cd(II) and Hg(II)) was studied on a series of ozonized activated carbon in aqueous phase. Commercial activated carbon (Filtrasorb 400) was treated with different ozone doses to study the effect of ozone treatment on its surface properties and investigate the behavior of the treated carbon samples in the above adsorption processes. After ozonation, carbonyl- and carboxyl-type...
Summary Purpose BMS-275183 is an oral C-4 methyl carbonate analogue of paclitaxel that has the same mechanism of action, stabilization of tubulin polymerization. The present study was designed to: (i) assess the safety and tolerability of BMS-275183, and (ii) determine a suitable Phase IIdose of BMS-275183 when given on a continuous daily schedule to patients with advanced solid tumor(s). Methods This was a multi-institutional, open-label, Phase I, single-arm dose escalation study in which cohorts of eligible patients with advanced malignancies were treated with BMS-275183 orally on a continuous daily schedule. The starting dose level was 6?mg/m2/day administered once daily. Cohorts of 3 patients were treated at each dose level provided no dose-limiting toxicities (DLTs) were observed. Ea...
Background and purpose: A series of phase I/II clinical trials are being initiated in several UK centres to explore the use of dose-escalated schedules for the treatment of non-small cell lung cancer (NSCLC). Among them the IDEAL-CRT trial (ISRCTN12155469) will investigate the introduction of individualised 'isotoxic' treatment schedules based on the relative mean lung normalised total dose (rNTDmean), an estimator related to lung toxicity. Since treatment planning will be performed using different treatment planning systems (TPSs), for the quality assurance of the trial we have carried out work to quantify the influence of dose calculation algorithms based on the determination of rNTDmean and on the choice of individualised prescription doses. Material and methods: Twenty-five patient plans with stage I, II and III NSCLC were calculated, with the same ...
The release rate of a nuclide from a reactor or a radioactive waste disposal plant at the accident is not steady, but varies with time. The various parameters of a nuclide migration into environment vary also day after day, or with the seasons. In such cases, dynamic behavior of the nuclide in the environment must be taken into consideration. It is difficult for a mathematical model to involve all of mechanisms for the nuclide migration. The environment for evaluation of doses are usually divided into some of compartments in which a nuclide concentration is uniform. Time variations of the nuclide concentration in the compartment are described in simultaneous differential equations. The nuclide concentration can be solved as a time function, and the radiation doses, therefore, can be estimated as a time function. Generic analysis code for dynamic compartment model (GACOM) is developed for the nuclide migration and the evaluation of ...
The rate was studied of radiation destruction of phenol aqueous solutions at a concentration range of 1 to 100 ppm. Irradiated were model solutions containing additions of some organic and inorganic substances typical of the petrochemical industry. In view of the fact that the radiation destruction kinetics is determined by the amount of dissolved oxygen in the sample and by the phenol concentration, relatively low doses were used. Thus, a sufficient amount of oxygen in the sample and therefore the oxidation mechanism of radiolysis were ensured. The dose-response relationships for phenol destruction were studied using doses of 50, 100, 200 and 400 J.kg"-"1; the limit dose was 500 J.kg"-"1. From the results obtained, a kinetic model was constructed of radiation phenol oxidation in aqueous solutions in the presence of various organic and inorganic additions. (B.S.).
PURPOSE: To determine the recommended dose of radiotherapy when combined with full-dose gemcitabine and erlotinib for unresected pancreas cancer. METHODS AND MATERIALS: Patients with unresected pancreatic cancer (Zubrod performance status 0-2) were eligible for the present study. Gemcitabine was given weekly for 7 weeks (1,000 mg/m(2)) with erlotinib daily for 8 weeks (100 mg). A final toxicity assessment was performed in Week 9. Radiotherapy (starting at 30 Gy in 2-Gy fractions, 5 d/wk) was given to the gross tumor plus a 1-cm margin starting with the first dose of gemcitabine. A standard 3 plus 3 dose escalation (an additional 4 Gy within 2 days for each dose level) was used, except for the starting dose level, which was scheduled to contain 6 patients. In general, Grade 3 or greater gastrointestinal toxicity was considered a dose-limiting ...
Angiotensin II has adverse actions in heart failure including vasoconstriction, aldosterone secretion, and activation of the sympathetic nervous system. Valsartan, a potent specific angiotensin II type 1 receptor blocker, may produce beneficial effects in heart failure. The purpose of this study was to evaluate the steady-state pharmacokinetics of valsartan 40, 80, and 160 mg each given every 12 h for 7 days in heart failure patients. Eighteen patients with chronic stable heart failure and left ventricular ejection fractions power model, showed that doubling the dose increased the AUC and Cmax 1.8 times. The pharmacokinetics of valsartan are predictable in heart failure patients within the dose range of 40-160 mg BID. Age did not appear to have influenced the valsartan clearance in heart failure patients. The pharmacokinetic values were higher in heart failure patients than in healthy volunteers. All ...
Treatment of food with low doses of gamma radiation has been recognized to have two main advantages. These consist of: (1) improvement of food safety by elimination of pathogens and (2) reduction of microbial spoilage and extension of shelf life of perishable items by reducing the number of viable spoilage organisms. Studies during the last few decades have conclusively proved the beneficial effects of radiation with respect to fishery products. The three potential areas of application to fish products include: (i) radurization for shelf life extension (ii) radicidation to eliminate food borne pathogens in the products and (iii) radiation treatment to dried products to control insects.
Perinatal exposure to cadmium (Cd) or methylmercury (MeHg) results in impaired neurodevelopment. Thyroid hormone is essential for normal brain development. However, the issue whether Cd or MeHg, especially at low doses, interrupts thyroid hormone action remains to be investigated. In the present study, effects of perinatal exposure to low levels of Cd or MeHg on thyroid hormone metabolism were examined using metallothionein I and II (MT-I/II) null or wild-type neonatal mice. Dams were exposed to 10 mg/L water of Cd or 5 mg/kg chow of MeHg from gestational day 0 to post-natal day 10 (PND 10). Sera, livers and brains were collected from neonates on PND 10. Iodothyronine deiodinase activities and serum thyroxine (T4) concentrations were measured. MeHg exposure failed to induce changes in serum T4 levels and liver type 1 deiodinase (D1) and brain type 2 deiodinase (D2) activities regardless of the MT genotype. However, exposure ...
Brachytherapy refers to short distance treatment of cancer with radiation from small, encapsulated radionuclide sources. This type of treatment is given by placing sources directly into or near the volume to be treated. The dose is then delivered continuously, either over a short period of time (temporary implants) or over the lifetime of the source to a complete decay (permanent implants). This technique is extensively used in the treatments of gynecological, breast, prostate, head and neck, and other soft tissue cancers. The clinical outcomes of this treatment depend on accurate dosimetry and dose delivery. The patient is generally considered to be water equivalent. So the treatment planning system software generally is based on measured or calculated dose distributions in homogenous water medium. In real situation, the treatment volume is not homogenous water medium, but it is a heterogeneous medium consisting of bone, ...
Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A computer ...
The potential of the dried yeast, wild-type Schizosaccharomyces pombe, to remove Ni(II) ion was investigated in batch mode under varying experimental conditions including pH, temperature, initial metal ion concentration and biosorbent dose. Optimum pH for biosorption was determined as 5.0. The highest equilibrium uptake of Ni(II) on S. pombe, q e, was obtained at 25??C as 33.8?mg?g?1. It decreased with increasing temperature within a range of 25?50??C denoting an exothermic behaviour. Increasing initial Ni(II) concentration up to 400?mg?L?1 also elevated equilibrium uptake. No more adsorption took place beyond 400?mg?L?1. Equilibrium data fitted better to Langmuir model rather than Freundlich model. Sips, Redlich?Peterson, and Kahn isotherm equations modelled the investigated system with a...
The purpose of the current study was to evaluate the difference in prognostic factors between stage IB and II uterine cervical carcinoma patients treated with postoperative radiation therapy. Between May 1988 and May 1998, a total of 94 patients including 47 patients with stage IB and 47 patients with stage II uterine cervical carcinoma were treated with postoperative radiation therapy at Tokyo Metropolitan Komagome Hospital. All patients were treated with 10 MV X-rays using an anterior-posterior parallel opposed field which covered the whole pelvis. Fractionation was 2 Gy per day, five fractions per week, to a total dose of 50 Gy. The 5-year overall survival rates of stage IB and II were 89.4% and 79.3%, respectively. In multivariate analysis for all patients, lymph node status, histology, and surgical margin status were recognized as prognostic factors. Limited to stage IB patients, lymph node status ...
Single-dose and repeated dose toxicity studies of prulifloxacin, a new antibacterial agent, were conducted in aged beagle dogs. I. A single-dose toxicity study Prulifloxacin was administered orally to aged female dogs at a single dose of 2500 and 5000 mg/kg. No death occurred in any group. Vomiting was observed in one of two animals at 2500 mg/kg and in both animals at 5000 mg/kg 3-4 hr after dosing. At 5000 mg/kg, vomiting was observed in both animals after feeding on the day after dosing. One animal also showed soft stool. Thereafter, no abnormalities were observed in any animal. No test article related changes were noted in food consumption, water consumption, body weight or pathological examination in any group. The results show that the lethal dose of prulifloxacin is judged to be greater than 5000 mg/kg in aged female dogs. ...
Secondary energy can be described as a surplus of electrical energy in a hydropower because the lower demand of energy in some period of the day and the excess of water in the reservoir during the rainy periods. This study proposes the using of the excess of energy at Itaipu Bi nacional for electrolytically hydrogen production and ammonia for nitrogenous fertilizers. Ammonia is a raw material for nitrogenous fertilizers synthesis and produced using hydrogen and nitrogen from the atmosphere. This paper determines the minimal cost of hydrogen production and the capacity of hydrogen production, with this data and according the ammonia market for nitrogenous fertilizers in the Centre/South region was estimated the better capacity of ammonia production for one plant near Itaipu. The process of ammonia production using energy excess is the most environmental acceptable. (author)
Phase II collimators will complement the existing system to improve the expected high RF impedance and limited efficiency of Phase I jaws. An international collaborative effort has been launched to identify novel advanced materials responding to the very challenging requirements of the new collimators. Complex numerical calculations simulating extreme conditions and experimental tests are in progress. In parallel, an innovative modular design concept of the jaw assembly is being developed to allow fitting in alternative materials, minimizing the thermally induced deformations, withstanding accidents and accepting high radiation doses. Phase II jaw assembly is made up of a molybdenum back-stiffener ensuring high geometrical stability and a modular jaw split in threes sectors. Each sector is equipped with a high-efficiency independent cooling circuit. Beam position monitors (BPM) are embedded in the jaws to fasten setup time ...
The accuracy of dose computation within the lungs depends strongly on the performance of the calculation algorithm in regions of electronic disequilibrium that arise near tissue inhomogeneities with large density variations. There is a lack of data evaluating the performance of highly developed analytical dose calculation algorithms compared to Monte Carlo computations in a clinical setting. We compared full Monte Carlo calculations (performed by our Monte Carlo dose engine MCDE) with two different commercial convolution/superposition (CS) implementations (Pinnacle-CS and Helax-TMS's collapsed cone model Helax-CC) and one pencil beam algorithm (Helax-TMS's pencil beam model Helax-PB) for 10 intensity modulated radiation therapy (IMRT) lung cancer patients. Treatment plans were created for two photon beam qualities (6 and 18 MV). For each dose calculation algorithm, patient, and beam quality, the ...
Once again Brazil faces the possibility of an electricity shortage in the near future. The low level of rain and the consequent reduction of hydroelectric reservoirs (hydroelectric energy represents almost 80% the total Brazilian electricity generation) led to the dispatch of thermal plants based on natural gas and/or fuel oil. However, the recent crisis regarding the Bolivian natural gas supply to Brazil increased the risk of a shortage of this energy source. Hence, the uncertainty of the electricity supply scenario is pushing the electricity prices up in the near future. A possible alternative to increase the electricity supply is the maximization of the electricity surplus in sugarcane mills. Back in 1970's and 1980's, cogeneration plants in sugarcane mills were primarily designed to consume all bagasse, and produce steam and electricity to the process. The plants used medium pressure steam boilers (21 bar and 300 deg C) and back pressure steam ...
Abstract in english Type II reaction in leprosy, or erythema nodosum leprosum (ENL), is often characterized by severe clinical symptoms together with nerve function impairment leading to permanent disabilities. Thalidomide has been shown to be a highly effective drug for the treatment of ENL. It is, however, contraindicated for women of childbearing age due to its teratogenicity. On the other hand, pentoxifylline, used to treat hypercoagulable states, is not teratogenic and, like thalidomide (more) , can inhibit the synthesis of tumor necrosis factor-a and other cytokines. In the present randomized double-blind clinical study we compared the effectiveness of orally administered pentoxifylline vs thalidomide in treating type II reaction in 44 patients. Daily doses of 300 mg thalidomide or 1.2 g pentoxifylline were administered for 30 days to multibacillary leprosy patients undergoing type II reaction. ...
A new three-dimensional treatment planning system (TPS) based on convolution/superposition algorithms (TMS-Radix from HELAX AB, Uppsala, Sweden) was recently installed at the University Hospital in Lund. The purpose of the present study was to design a quality assurance and acceptance testing programme to meet the specific characteristics of this convolution model. The model is based on parametrization of a non-measurable quantity - the polyenergetic pencil beam. However, the verification of the treatment planning model is still dependent on numerous comparisons of measured depth-doses and dose profiles. The test programme was divided in two basic parts: (i) model implementation and beam data consistency and (ii) model performance and limitations in special situations. The first part was scheduled for all photon beam qualities available before they could be used for clinical treatment planning. The second part was performed ...
The T/sub c/ behavior of vapor-deposited Nb_3Ge and Nb_3Sn is examined as a function of low-fluence alpha-particle irradiation. It is found that for Nb_3Sn with rho_0approx.15 #mu##OMEGA#-cm the T/sub c/ is insensitive to low doses of radiation, whereas Nb_3Ge with rho_0approx.50 #mu##OMEGA#-cm has its T/sub c/ depressed immediately with irradiation. It is suggested that the T/sub c/ behavior of A-15 superconductors in the regime of small dose is strongly influenced by the initial state of the sample. Furthermore, it is argued that the behavior of the T/sub c/ with dose can be qualitatively explained by considering a sharp structure in the density of states N(E), the smearing of which by defects leads to a depression in T/sub c/.
We have tested the suitability of a new single-aliquot regenerative-dose protocol for estimating the equivalent dose (D_e) in polymineral fine grains extracted from colluvia from various sites in Germany. First, we report the behaviour of three OSL signals: (i) blue-stimulated, (ii) infrared-stimulated luminescence, and (iii) blue-stimulated luminescence following infrared (IR) stimulation, using a near-UV (290-380 nm) detection window in each case. For these three signals, there is a significant change in sensitivity with regeneration cycle; this change can be compensated for using the response to a fixed test dose after each natural or regenerated measurement. The source of the three luminescence signals is then investigated using pulse-anneal and elevated-temperature experiments. Fading tests on laboratory-induced signals show that although the IR signals fade by up to 23% in 15 days at 100 deg. C, ...
The disposition of three (1-/sup 14/C)-chlorododecanes (MCDD, PCDD I and PCDD II; 17.4%, 55.9%, and 68.5% chlorination) was studied in C57Bl mice. (1-/sup 14/C)-lauric acid (LA) was studied as reference compound. Fifty-two percent (MCDD), 32% (PCDD I), and 8% (PCDD II) of the radioactive doses were exhaled as /sup 14/CO/sub 2/ during 12 h after i.v. injection. Similar results were obtained after p.o. administration. In addition to a marked labelling of the liver and fat, the distribution patterns observed at 24 h after administration revealed an uptake of radioactivity in tissues with high cell turnover/high metabolic activity, e.g., intestinal mucosa, bone marrow, salivary glands and thymus. The concentration of radioactivity in these sites and the exhalation of /sup 14/CO/sub 2/, which were inverse to the degree of chlorination, indicate that the chloroalkanes are degraded to metabolites which can be utilized in the ...
Purpose: The purpose of this course is to review the physical principles underlying design, clinical application and execution of interstitial and intracavitary implants in the classical low dose-rate (LDR) range. This year, the course will focus on quality assurance of sources, applicators and treatment planning software. In addition, development of procedures and QA checks designed optimize treatment delivery accuracy and patient safety during each individual procedure will be reviewed. The level of presentation will be designed to accommodate both physicists and physicians. Implementation of recently published AAPM Task Group reports (no. 40, 'Comprehensive Quality Assurance' and No. 43, 'Dosimetry of Interstitial Brachytherapy Sources') will be reviewed. Outline: (A) General Principles (1) QA endpoints: temporal accuracy, positional accuracy, dose delivery accuracy, and safety of the patient, personnel, and the institution (2) QA procedure ...
Full text: Semiconductor detectors coated with boron or lithium compounds have been studied for neutron detection for decades but, until recently, have been limited to thermal neutron detection efficiencies of less than 5%. We reported previously on development and simulation studies of perforated detectors whose perforations are filled with neutron-reactive material in order to produce higher detection efficiencies. Incorporation of bare and cadmium-backed detectors into battery-powered devices with low-power electronics enables us to produce compact personal neutron dosimeters that provide LED readout of counts, which can be related approximately to neutron dose. We report here on experimental studies with such compact devices; devices capable of direct readout in dose units are anticipated. The thermal and epithermal neutron flux densities from the tangential beam tube of the TRIGA Mark II reactor at Kansas State ...
Purpose: Antitumor activity of the dichloroplatinum(II)-histamine complexes labeled with I-125 or I-131 was investigated in a transplantable murine adenocarcinoma (MA) model. Methods: The tumor model was obtained in C3H/W female mice after subcutaneous inoculation of the tumor cells derived from the mice bearing a mammary tumor of spontaneous origin. Antitumor activities of the platinum-histamine complexes were investigated in three independent experiments, which differed in applied doses of preparations (PtCl{sub 2}Hist, PtCl{sub 2}[{sup 125}I]Hist, PtCl{sub 2}[{sup 131}I]Hist, PtCl{sub 2}Hist/PtCl{sub 2}[{sup 125}I]Hist and PtCl{sub 2}Hist/PtCl{sub 2}[{sup 131}I]Hist), treatment schedules as well as stages of the disease progress in the animals used. Experiment 1 included long-term, multidose treatment with low single doses (treatment duration 31-32 days; 8-10 doses of ca. 0.25{center_dot}MTD{sub Pt} ...
CBA/Ca mice were infected by either the intravenous or intraperitoneal route with Mycobacterium microti and the subsequent changes in local macrophage populations examined. Following infection, the number of macrophages increased and they showed greater expression of both MHC Class II molecules. This response was not dependent on viability of the mycobacteria, in contrast to reports with other microorganisms such as Listeria. Studies in sublethally irradiated mice indicated that persistent antigen could give rise to a response after a period of host recovery which was radiation dose dependent. This procedure also highlighted differences in the regulation of different murine class II antigens in vivo, as seen by delayed re-expression of I-E antigens. Macrophage accessory cell function, as assessed by an in vitro T cell proliferation assay, correlated with Ia expression after fixation, but not after indomethacin treatment; ...
A few metal complexes of isatin-isonicotinoylhydrazone with Ni(II), Cr(III), Co(II), Cu(II), Zn(II) and Cd(II) have been prepared and characterized on the basis of elemental analyses, infrared and electronic spectra as well as "1H NMR spectra, conductivity and magnetic measurements. In view of the results obtained, it has been found that two molecules of isatin-isonicotinoylhydrazone are chelated to the central metal ion as bis-uninegative ONO tridentate ligand forming non-electrolytic octahedral metal complexes. (author)
Gallium is present in surplus weapons-grade plutonium (WG-Pu) at a concentration of approximately 1 wt %. Plans are to dispose of surplus WG-Pu by converting it to UO{sub 2}-PuO{sub 2} mixed oxide (MOX) fuel and irradiating it in commercial power reactors. However, the presence of high concentrations of gallium in plutonium poses a potential corrosion problem during the process of MOX fuel irradiation. The batch experiments performed in this study were designed to measure the capability of the PUREX solvent extraction process to separate gallium from plutonium under idealized conditions. Radioactive tracing of the gallium with {sup 72}Ga enabled the accurate measurement of low concentrations of extractable gallium. The experiments approximated the proposed flowsheet for WG-Pu purification, except that only one stage was used for each process: extraction, scrubbing, and stripping. The gallium decontamination factor (DF) obtained after one ...
With the end of the cold war the United States, Russia, and other countries have excess plutonium and other materials from the reductions in inventories of nuclear weapons. The United States Academy of Sciences (NAS) has recommended that these surplus fissile materials (SFMs) be processed so they are no more accessible than plutonium in spent nuclear fuel (SNF). This spent fuel standard, if adopted worldwide, would prevent rapid recovery of SFMs for the manufacture of nuclear weapons. The NAS recommended investigation of three sets of options for disposition of SFMs while meeting the spent fuel standard: (1) incorporate SFMs with highly radioactive materials and dispose of as waste, (2) partly burn the SFMs in reactors with conversion of the SFMs to SNF for disposal, and (3) dispose of the SFMs in deep boreholes. The US Government is investigating these options for SFM disposition. A new method for the disposition of SFMs is described herein: the simultaneous ...
The conversion of off-peak surplus electricity into peak electricity through an electrolyzer, hydrogen storage, and fuel cell energy storage system was discussed. Development efforts in high pressure alkaline electrolysis and Proton-Exchange Membrane (PEM) fuel cells have improved the near-term viability of these systems. Potential use of wind turbines and other renewable energy-based generation systems, through hydrogen-based energy storage, were discussed as a new supply of surplus electricity. An integrated set of nomographs were presented for providing quick estimates of peak electricity costs derived from an electrolyzer/hydrogen fuel cell system. The nomographs allowed first order cost comparisons of centralized versus distributed hydrogen energy systems considering trade-offs between production economies of scale and hydrogen storage and transport costs. Use of the nomographs to compare centralized and dispersed systems was demonstrated. ...
Hematopoietic stem cell transplantation provides the only potential curative option in many patients with hematological malignancies. Finding a suitably matched donor in a timely manner is often difficult. However, most patients have a partially HLA-mismatched (HLA-haploidentical) first-degree relative readily available. Historically, HLA-haploidentical bone marrow transplantation (BMT) has been considered extremely high risk due to high rates of life-threatening graft-versus-host disease (GVHD) and non-relapse mortality (NRM). Modifications of the stem cell graft, such as T-cell depletion, have resulted in poor rates of engraftment. We have recently completed a phase II clinical trial of nonmyeloablative HLA-haploidentical hematopoietic BMT followed by post-transplantation high-cyclophosp...
A novel envelope-type radon monitor has been used for short-term (as little as 1 week) radon concentration measurements in a workplace environment. The commercially available LR-115 type II damage track detector was used in this study and the chemically etched sheets were spark counted. The measurements were made over a period of 1 year in a workplace consisting of three adjacent rooms situated in the lower ground level of multistorey office building in Rome, Italy. The variations of the radon concentration are from [approx] 20 to [approx] 300 Bq m[sup -3] with averages of 130,81 and 73 Bq m[sup -3] for the three different rooms resulting in annual doses of [approx] 3.8, [approx] 2.4 and [approx] 2.2 mSv, respectively. (author) 2 figs., 9 refs.
The results of this study are in agreement with the precepts established in studies published previously on beef, chicken, ham, and pork. The radiolysis compounds from bacon, chicken, ham, and pork are comparable in identity and amounts to those found in irradiated beef for comparable compositions and irradiation parameters (temperature, dose, etc.). The results of this study support the conclusions drawn in the CORC report of 'commonality in chemistry, predictability of products, and extrapolation of results.' Consequently, the same conclusions can be drawn concerning the wholesomeness of irradiated bacon, chicken, ham, and pork as for other irradiated meat products of similar composition and irradiation parameters as reported in the FASEB report and its supplements (I and II) on irradiated beef.
Annual wormwood interference on soybean crop growth and yield may result from competition and allelopathy, which are modulated by crop management. Allelochemicals released by annual wormwood (e.g. artemisinin) may affect the crop directly or indirectly through the effect on the nitrogen fixing symbiont, Bradyrhizobium japonicum. The objectives were (i) to quantify the crop response (i.e. biomass production, nodulation and yield) to weed interference and (ii) to determinate the relative change of competition and allelopathy interferences, when a sublethal dose of herbicide is applied. Two split plot field experiments with three replications were used. The experiment involved a factorial combination of five weed-crop density (soybean/annual wormwood, plantsm^-^2) levels: D1, pure soybean, 40...
Charge carrier profiles are measured for boron implanted into silicon (E = 30 keV, dose range 5 x 10"1"5 to 2 x 10"1"6 B/cm"2) after rapid isothermal annealing using halogen lamps. Maximum temperatures between 1000 and 1300 "0C and holding times at T/sub max/ of 5 and 20 s are used for the annealing treatment. In a few additional experiments flash lamp annealing at 1350 "0C (pulse duration 20 ms) is investigated. By comparison of the experimental profiles with computer simulations using the SUPREM II program transient enhanced diffusion of boron could be detected in all investigated cases. Maximum charge carrier concentrations above the equilibrium solubility of boron are observed and are discussed. (author).
Nuclear radiation detectors in integral execution were produced by successive epitaxial growth from vapor phase of Zn Te and Cd Se thin layers onto scintillating Zn Se (Te) crystals. The irradiation of combined Zn Se (Te) - Zn Te - Cd Se detectors by Cu_K_a X-rays leads to the appearance of photoreceiver e.m.f., which tends to saturation with the increase of X-ray radiation dose reaching the value of 0.34-0.40 V at 200 R/min. The short circuit current dependence of irradiation dose power is linear. The matching factor for detectors with Zn Te-Cd Se photoreceivers with different doping levels is 0.68-0.92. The absolute monochromatic sensitivity is 0.32-0.35 m A/m W at a quantum efficiency 0.58-0.61 and a time constant 2 x 10"-"4 s. The calculated dose sensitivity for Zn Se(Te)-Zn Te-Cd Se combined detectors at the irradiation with X-rays having effective energy 8.86 keV gives the value 3.9 x 10"-"7 A/cm"2 (R/min); the ...
By the use of thermoluminescence (TL) technique we have investigated the effects of gamma irradiation on the TL response of pulverised natural zircon (ZrSiO{sub 4}) crystals from the Jos Plateau area of Nigeria. Samples of the mineral that have been previously annealed were artificially irradiated to moderate gamma doses ranging from 0.7 to 4.9 Gy using {sup 60}Co gamma-source of the CERD. The natural TL glow curve of the sample showed a broad peak around 250 deg. C, the peak was however, found to be completely erased following heat treatment for 2 h at 400 deg. C. The TL glow curves of the artificially irradiated samples showed two overlapping glow peaks at about 112 deg. C (peak I) and at 156 deg. C (peak II) within the dose range utilised. We note that the natural TL peak appears to be different from the two observed in the artificially irradiated sample. The TL response with dose was investigated ...
By the use of thermoluminescence (TL) technique we have investigated the effects of gamma irradiation on the TL response of pulverised natural zircon (ZrSiO_4) crystals from the Jos Plateau area of Nigeria. Samples of the mineral that have been previously annealed were artificially irradiated to moderate gamma doses ranging from 0.7 to 4.9 Gy using "6"0Co gamma-source of the CERD. The natural TL glow curve of the sample showed a broad peak around 250 deg. C, the peak was however, found to be completely erased following heat treatment for 2 h at 400 deg. C. The TL glow curves of the artificially irradiated samples showed two overlapping glow peaks at about 112 deg. C (peak I) and at 156 deg. C (peak II) within the dose range utilised. We note that the natural TL peak appears to be different from the two observed in the artificially irradiated sample. The TL response with dose was investigated for the two ...
Background and purpose: In order to investigate the feasibility, toxicity and antitumor efficacy of hyperfractionated radiation therapy, 37 adult patients with incompletely resected supratentorial low-grade glioma were entered into a phase II study. Materials and methods: The radiation therapy dose was 55 Gy in 50 fractions in 25 treatment days over 5 weeks to the tumor plus a 2-cm margin, with an additional 17.6 Gy given in 16 fractions in 8 treatment days over 1.5 weeks to the tumor plus a 1-cm margin, using 1.1 Gy b.i.d. fractionation with a 6 h interfraction interval. The total tumor dose was 72.6 Gy in 66 fractions in 33 treatment days over 6.5 weeks. Results: The median survival time (MST) for all 37 patients has not yet been attained, while 5- and 7-year survival rates were 75% and 69%, respectively. The median time to tumor progression (MTP) has also not yet been attained, while 5- and 7-year progression-free ...
Platinum(II) complexes have been investigated in the hydration of alkynes. These catalysts offer improved regioselectivity over Hg(II) counterparts. 1 fig., 2 tabs.
A vendor glass formulation study was carried out at Pacific Northwest Laboratory (PNL), supporting the Phase I and Phase II melter vendor testing activities for Westinghouse Hanford Company. This study is built upon the LLW glass optimization effort that will be described in a separate report. For Phase I vendor melter testing, six glass formulations were developed at PNL and additional were developed by Phase I vendors. All the doses were characterized in terms of viscosity and chemical durability by the 7-day Product Consistency Test. Twelve Phase II glass formulations (see Tables 3.5 and 3.6) were developed to accommodate 2.5 wt% P{sub 2}O{sub 5} and 1.0 wt% S0{sub 3} without significant processing problems. These levels of P{sub 2}O{sub 5} and SO{sub 3} are expected to be the highest possible concentrations from Hanford Site LLW streams at 25 wt% waste loading in glass. The Phase H compositions formulated were 6 to 23 ...
Silicon on insulator (SOI) structures are promising candidates for the fabrication of VLSI circuits with very high packing densities. The preparation of such structures can now be achieved by high dose implantation of reactive ion species such as oxygen to produce buried layers of SiO/sub 2/ in silicon. In this paper we report experiments to depth profile these layered structures by SIMS. SOI samples have been prepared by implanting (100) silicon wafers with 400 keV molecular oxygen ions at a dose of 1.8x10/sup 18/ O/sup +/ cm/sup -2/. During the implantation the wafers were maintained at temperatures between 325 and 600/sup 0/C, using beam heating, which achieved in situ-annealing and ensured that the top silicon layer remained single crystal. Analysis was carried out on an Atomika DIDA-II spectrometer using 10 keV Ar/sup +/ ions with a low current density of less than 1 mA cm/sup -2/. During analysis negative secondary ...
From 1977 through 1984, 293 previously untreated patients with biopsy proven carcinoma of the uterine cervix were treated by whole pelvis irradiation and high intensity 60Co remote afterloading (RAL) intrauterine tandem techniques in Haiti. The treatment results were analyzed retrospectively to evaluate the therapeutic results and prognostic factors of a strict protocol involving 40 Gy to the whole pelvis (2 Gy/day, 5 days/week). In addition, on the 5th day of the 3rd week, the first outpatient 60Co remote afterloading intracavitary insertion, delivering 7.5 Gy to point A with each insertion, repeated 3 times by a week separation for a total of 4 times. The total TDF for external beam plus RAL was 158 and 175 for early and late effects respectively. One hundred-four patients were evaluable after 1 year or more follow-up, with a median of 26.5 months. No evidence of disease (NED) by Stage at 1 year was: Stage I of 100% (3/3), Stage II of 82% (9/11), Stage III of 80% ...
Most plans for the disposition of surplus nuclear materials involve storage in sealed containers where the evolution of gases from reactions of adsorbed water could present both pressure and flammability hazards[l] . Despite efforts such as calcining the material to minimize the water content prior to packaging, both residual moisture and readsorbed water may be present in the final containers . Given the anticipated temperature excursions during transportation and storage, this water may thermally desorb, increasing the pressure, and/or thermally dissociate to produce H2 gas, increasing flammability hazards . In addition, the radiation from the nuclear material may induce radiolysis of the water with the likely products being water vapor, H2, 02 and H2O2. In order to better understand the relative importance of the thermal- and radiationinduced chemistry, we have studied the interactions of water on single crystals of uranium dioxide .
Surveillance and maintenance (S & M) of 75 sites were conductd by the Remedial Action Section for the Environmental Restoration Program for surplus facilities and sites contaminated with radioactive materials and/or hazardous chemicals. S & M activities on these sites were conducted from the end of their operating life until final facility disposal or site stabilization. The objectives of the Waste Area Grouping S & M Program are met by maintaining a program of routine S & M as well as by implementing interim corrective maintenance when deemed necessary as a result of site surveillance. This report briefly presents this program`s activities and includes tables indicating tank levels and dry well data for FY 1991.
Surveillance and maintenance (S M) of 75 sites were conductd by the Remedial Action Section for the Environmental Restoration Program for surplus facilities and sites contaminated with radioactive materials and/or hazardous chemicals. S M activities on these sites were conducted from the end of their operating life until final facility disposal or site stabilization. The objectives of the Waste Area Grouping S M Program are met by maintaining a program of routine S M as well as by implementing interim corrective maintenance when deemed necessary as a result of site surveillance. This report briefly presents this program's activities and includes tables indicating tank levels and dry well data for FY 1991.
Tata Electric Companies (TEC) are engaged in the generation of hydro and thermal energy. TEC, to minimise backing down of its thermal units in off peak hours and also to at least partially meet the growing deficit in the supply during peak hours is moving to install pumped storage plants (PSPs) utilising off-peak surplus energy for pumping the water from lower pond to the upper pond for subsequent utilisation for power generation during peak hours. In view of some of the infra structural facilities such as storage ponds, water conductor system, transmission lines, etc. being already available, at the existing hydro power stations owned by TEC, the pumped storage units are being proposed within the environs of existing hydro stations, i.e. a 150 MW pumped storage unit at Bhira and a 90 MW pumped storage unit at Bhivpuri. The projects are described and cost estimates is given. (author). 2 figs.
PROCAMPO (Program for Direct Assistance in Agriculture or Programa de Apoyos Directos al Campo) is an income transfer payment to Mexican farmers that compensates them for subsidies received by foreign competitors. Corn (Zea mays) has received the largest amount of PROCAMPO payments and is the primary component of Mexico?s food and feed supply. Results of a spatial and temporal model show that without PROCAMPO, Mexican annual average corn production would have been lower and corn imports would have been 40.5% higher in 2005?2007. Increased producer and consumer surplus and savings from reduced imports reveal that the benefits of PROCAMPO were higher than the program?s costs. Greater PROCAMPO support would decrease Mexican corn imports and increase domestic corn production. It is recommended...
When operating a nuclear power plant the necessity arise to eliminate various defects of building constructions, to seal joints and transitional elements. The authors present data concerning the production of a sealing composition made of epoxy resin and used for NPP premises of emergency location. Analytical relations are presented between the properties of the composition (adhesion strength, water absorption and others) and its structure. Physical, mechanical and thermal properties and structural peculiarities are determined in the process of interaction between the filling and binding agents. The composition sustains sealing properties under environmental conditions at he presence of an air - vapour mixture with 160 degrees C"o temperature and 0.3 MPa surplus pressure. (author).
A model is presented to account for the effects of ion-induced defects during implantation processing of Si. It will be shown that processing is quite generally affected by the presence of defect excesses rather than the total number of defects. a defect is considered excess if it represents a surplus locally of one defect type over its compliment. Processing spanning a wide range of implantation conditions will be presented to demonstrate that the majority of the total defects played little or no role in the process. This is a direct result of the ease with which the spatially correlated Frenkel pairs recombine either dynamically or during a post-implantation annealing. Based upon this model, a method will be demonstrated for manipulating or engineering the excess defects to modify their effects. In particular high-energy, self-ions are shown to inject vacancies into a boron implanted region resulting in suppression of transient enhanced diffusion of the dopant.
The purpose of this study is to search for a new method of dispersing spilled heavy oil, which has a detrimental effect on the natural environment and marine ecosystem. A method ejecting a waterjet vertically downward to heavy oil on the water surface was studied, particularly focusing on the effect of the guide nozzle shape. The waterjet comprised heavy oil and minute air bubbles, and passed through the hole of the guide nozzle. Thirteen guide nozzle shapes were tested and compared. The dispersion efficiency of a tapered hole was the best among the 13 nozzles. The flow in the hole of the guide nozzles was recorded by a high-speed video camera. The occurrence of two flows, regular and counter flows, was observed in the taper guide nozzle. It seemed that the counter flows generated the shearing force between the waterjet and the heavy oil layer. It is considered that the shearing force determines the surplus efficiency of disperse.
Abstract Large areas of the southern European countries possess a Mediterranean climate, which influences soil properties, land use, fertilizer application practices and pathways of phosphorus (P) loss from agricultural soils. On average, inputs of fertilizer P exceed P exports from the agricultural areas in these countries; however, large differences in P surplus/deficit and soil P test values exist among regions. Losses of P in drainage water are modest except in some irrigated areas and in those regions where intensive animal production is concentrated. Losses of P in runoff water, whether as dissolved reactive or particulate P, can be substantial as a result of the significance of erosive processes under the land uses typical of the Mediterranean region, where extreme rainfall events c...
In this paper, we propose a bid optimizer for sponsored keyword search auctions which leads to better retention of advertisers by yielding attractive utilities to the advertisers without decreasing the revenue to the search engine. The bid optimizer is positioned as a key value added tool the search engine provides to the advertisers. The proposed bid optimizer algorithm transforms the reported values of the advertisers for a keyword into a correlated bid profile using many ideas from cooperative game theory. The algorithm is based on a characteristic form game involving the search engine and the advertisers. Ideas from Nash bargaining theory are used in formulating the characteristic form game to provide for a fair share of surplus among the players involved. The algorithm then computes the nucleolus of the characteristic form game since we find that the nucleolus is an apt way of allocating the gains of cooperation among the search engine and the advertisers. The ...
Digital control technology using micro-processor is widely used in Factory Automation area since 1980`s. However, the D{sub 2}O Vapour Recovery System in Wolsung 1 N.P.P is controlled by mechanical timer without considering the moisture condition in the Reactor Building and bed temperature, because it was designed using analog technology of 1960`s. This leads to the inefficient system operation and low D{sub 2}O recovery rate in addition to the high internal dose rate of operator. The goal of this phase II study is to develope a optimal automatic controller of D{sub 2}O vapour recovery system using PLC. We developed a control algorithm for Dual Tower Drier, a PLC control program, a operation change program and the monitoring system with a real-time simulator for system verification. (author). 15 refs., 11 figs., 2 tabs.
Wood Plastic Composite (WPC) was prepared with simul (soft wood, density = 0.4g/cc) and butylmethacrylate (BMA) monomer using 10% methanol as the swelling agent. Effect of additives including (i) multifunctional acrylates such as tripropylene glycol diacrylate (TPGDA), trimethylol propane triacrylate (TMPTA) (ii) oligomer acrylates like the urethane (UA), epoxy (EA) and polyester (PEA) acrylates and (iii) N-vinyl pyrrolidone (NVP) was investigated using 1 to 3 Mrad dose at 0.8 Mrad/h. Synergistic increases in polymer loading yields was achieved in presence of the additives, particularly with the trifunctional acrylate (TMPTA). In addition, acid as well as urea were also used as co-additives and synergistic enhancement in yields of polymer loading were obtained. The synergistic polymer loading by acid addition causes substantial decrease in tensile strength of the composite; but other additives and co-additives increase both the polymer loading ...
In 1959, the Test Manager's Committee to Establish Fallout Doses calculated estimated external gamma exposure at populated locations based upon measurements of external gamma-exposure rate. Using these calculations and estimates of population, we have tabulated the collective estimated external gamma exposures for communities within established fallout patterns. The total collective estimated external gamma exposure is 85,000 person-R. The greatest collective exposures occurred in three general areas: Saint George, Utah; Ely, Nevada; and Las Vegas, Nevada. Three events, HARRY (May 19, 1953), BEE (March 22, 1955), and SMOKY (August 31, 1957), accounted for over half of the total collective estimated external gamma exposure. The bases of the calculational models for external gamma exposure of ''infinite exposure,'' ''estimated exposure,'' and ''one year effective ...
New tetradentate N(2)O(2) donor Schiff bases and their mononuclear Co(II), Ni(II), Cu(II), and Pd(II) complexes were synthesized and characterized extensively by IR, (1)H-, (13)C-NMR, mass, ESR, conductivity measurements, elemental and thermal analysis. Specifically the magnetic and electronic spectral measurements demonstrate the octahedral structures of cobalt(II), nickel(II) complexes and square planar geometries of copper(II), palladium(II) complexes. All the ligands and complexes were screened for their in vitro antibacterial activity against two gram-positive bacteria (Bacillus subtilis, Staphylococcus aureus) and two gram-negative bacteria (Escherichia coli, Klebsiella pneumonia). In this study, Pd(II) complexes exhibited potent antibacterial activity against B. subtilis, S. aureus whereas ...
This report deals with the preliminary results of trials in the DATECA project with stage I, II and III patients with non-seminomatous germ cell tumours. Stage 1 patients were randomized between infradiaphragmatic irradiation and observation. No significant difference in recurrence rates has been observed as yet. Eighteen of 95 patients had recurrence with a median time to relapse of 3 months. Fifteen patients achieved complete remission after treatment by combination chemotherapy while 3 patients are still undergoing treatment. Stage II patients received 6 series of cis-platinum, bleomycin, and vinblastine. The patients were initially randomized to receive chemotherapy alone versus chemotherapy plus irradiation. Irradiation led to increased toxicity and decreased doses of the antineoplastic drugs. Fifty-one patients were studied. The overall complete remission rate was 89 per cent including 7 patients who achieved complete ...
This report deals with the preliminary results of trials in the DATECA project with stage I, II and III patients with non-seminomatous germ cell tumours. Stage 1 patients were randomized between infradiaphragmatic irradiation and observation. No significant difference in recurrence rates has been observed as yet. Eighteen of 95 patients had recurrence with a median time to relapse of 3 months. Fifteen patients achieved complete remission after treatment by combiantion chemotherapy while 3 patients are still undergoing treatment. Stage II patients received 6 series of cis-platinum, bleomycin, and vinblastine. The patients were initially randomized to receive chemotherapy alone versus chemotherapy plus irradiation. Irradiation led to increased toxicity and decreased doses of the antineoplastic drugs. Fifty-one patients were studied. The overall complete remission rate was 89 per cent including 7 patients who achieved complete ...
Background: EGFR (epidermal growth factor receptor) and VEGF (vascular endothelial growth factor) inhibitors confer clinical benefit in metastatic colorectal cancer when combined with chemotherapy. An emerging strategy to improve outcomes in rectal cancer is to integrate biologically active, targeted agents as triple therapy into chemoradiation protocols. Material and methods: cetuximab and bevacizumab have now been incorporated into phase I-II studies of preoperative chemoradiation therapy (CRT) for rectal cancer. The rationale of these combinations, early efficacy and toxicity data, and possible molecular predictors for tumor response are reviewed. Computerized bibliographic searches of Pubmed were supplemented with hand searches of reference lists and abstracts of ASCO and ASTRO meetings. Results: the combination of cetuximab and CRT can be safely applied without dose compromises of the respective treatment components. Disappointingly low ...
Two neutron emesis experiments were conducted at the Armed Forces Radiobiology Research Institute (AFRRI). In both experiments (described as Phase I and Phase II) the radiation dose required to cause emesis in 50% of subjects (ED50) was determined for both neutron reactor and gamma reactor source radiation. Emesis onset, offset and duration times post-exposure are reported. Neutrons were maximized from the reactor by passing the beam through a 15.25 cm (6 in.) thick lead wall to filter out gamma photons. Gamma rays were maximized by thermalizing neutrons in 30.5 cm (12 in.) of water, then absorbing the thermal neutrons in a gadolinium-cadmium shield. In Phase I, 28 dogs were exposed to radiation: 12 were exposed to gamma photons at the rate of 0.69 Gy/min and 16 were exposed to neutrons at 1.2 Gy/min. In Phase II, 58 dogs in 3 groups were exposed to radiation: 19 were exposed in the gamma group at 0.75 Gy/min, 20 were ...
In this experiments, we established long-termed culture methods of bone marrow stromal cells for proliferation and differentiation of stem cells. And we selected some extracts which support maximal proliferation of stromal cells with this method. We conformed the synergic effects of herbal mixture extracts for stromal cell growth. The proliferation of stromal cells was increased rather by the addition of mixture extracts than by addition of single strain extract. In the previous and cooperative experiments, we selected complex extracts (Him-I, Him-II) which increased the number of nonadherent mononuclear cells. Different cytokine expression patterns were observed stromal cells cultured in the presence or absence of mixture extracts which support differentiation of nonadherent cells. Some fractions of Him-I and Him-II increased the proliferation of bone marrow cells irradiated {gamma}-ray(4Gray). Stimulation of macrophage cell line with herval ...
Some acylhydrazine derived ONO donor Schiff bases and their Co(II) and Ni(II) complexes have been prepared having the same metal ion (cation) but different anions. These synthesized metal(II)...Full Text Available
Background and Purpose: In an earlier phase II study, irradiation together with razoxane was shown to improve local control in recurrent rectal cancer. Therefore, the Austrian Society of Radiooncology (OeGRO) initiated a randomized controlled trial in 1992 to compare this combined treatment versus radiation therapy alone. Patients and Methods: Between 1992 and 1999, 36 patients with localized recurrences of rectal cancer were randomized to receive radiotherapy without (group A) or with razoxane (group B). The prognostic variables of the two groups were similar except for a longer median latency period from initial surgery to local recurrence in group A. High-energy photons with daily fractions between 170 and 200 cGy were used. The median total radiation dose was 60 Gy in each group. The patients in group B received a median razoxane dose of 9.6 g (range, 5-12 g). Main outcome measures were local control, overall survival, ...
A structurally conserved element, the trigger loop, has been suggested to play a key role in substrate selection and catalysis of RNA polymerase II (pol II) transcription elongation. Recently resolved...Full Text Available
The insulin/IGF-1 signaling (IIS) pathway is a conserved regulator of longevity, development, and metabolism. In Caenorhabditis elegans IIS involves activation of DAF-2 (insulin/IGF-1...Full Text Available
DNA from the peripheral blood mononuclear cells of 17 different individuals infected with human T-cell lymphoma/leukemia virus type II (HTLV-II) was successfully amplified by the polymerase chain reaction...Full Text Available
The results of this research centered on the experimental studies of a single superconducting persistent current qubit, the implementation of type-II algorithms using these qubits, and the proposal for adiabatic quantum computing using these qubits. The m...
The in vivo photochemical activity of photosystem II was inferred from modulated chlorophyll fluorescence and photoacoustic measurements in intact leaves of several plant species (Lycopersicon...Full Text Available
Woolfolk, C. A. (University of Washington, Seattle). Reduction of inorganic compounds with molecular hydrogen by Micrococcus lactilyticus. II. Stoichiometry with inorganic...Full Text Available
... and high-quality photospheric-phase Type II SN spectra to constrain core- collapse SN explosions, massive star evolution, and distances in the Universe ...
This document describes payload control at LLNL to ensure that all shipments of CH-TRU waste in the TRUPACT-II (Transuranic Package Transporter-II) meet the requirements of the TRUPACT-II SARP (safety report for packaging). This document also provides specific instructions for the selection of authorized payloads once individual payload containers are qualified for transport. The physical assembly of the qualified payload and operating procedures for the use of the TRUPACT-II, including loading and unloading operations, are described in HWM Procedure No. 204, based on the information in the TRUPACT-II SARP. The LLNL TRAMPAC, along with the TRUPACT-II operating procedures contained in HWM Procedure No. 204, meet the documentation needs for the use of the TRUPACT-II at LLNL. Table 14-1 provides a summary of the LLNL waste generation and ...
Biosorption using activated sludge biomass (ASB) as a potentially sustainable technology for the treatment of wastewater containing different metal ions (Cd(II), Pb(II) and Zn(II)) was investigated. ASB metal uptake clearly competed with protons consumed by microbial biomass compared with control tests with non-activated sludge biomass. Biosorption tests confirmed maximum exchange between metal ions and protons at pH 2.0-4.5. It was revealed by the study that the amount of metal ions released from the biomass increased with biomass sludge concentration. The result showed that maximum absorption of metal ions was observed for Cd(II) at pH 3.5, Pb(II) at pH 4.0, and pH 4.5 for Zn(II) ions. The maximum absorption capacities of ASB for Cd(II), Pb(II) and Zn(II) were determined to be 59.3, 68.5 and 86.5%, ...
Method for description of X-ray radiation dose distribution based on semiempirical description of dose fields is suggested. At that dose field description parameters can be easily individualized for concrete X-ray device.
Examples are used to demonstrate that a shift in the point of emphasis is necessary with regard to radiation hazard in medicinal X-ray diagnosis. The parameters employed in this study to calculate somatic dose (SD) and somatically significant dose (SSD) m...
Dosimetric studies in 80 patients examined with the tomographic device 'Somatom' are reported. The gonad doses are compared to those of conventional radiographic techniques.
In the present study an estimate is made of the malignancy significant dose from external beam radiotherapy in New Zealand utilizing data obtained in a survey conducted in 1975. This survey had been designed to assess genetically significant dose. A weighted effective dose equivalent is derived from the malignancy significant dose for direct comparison with mean per capita effective dose equivalents arising from other sources of radiation. 14 refs., 1 fig., 8 tabs.
A simple dose-saving procedure for the diagnosis of congenital hip dysplasia employing a diaphragm in nearfocus position is presented. Doses to the skin and the gonads were measured with a phantom for the new and other techniques. With optimal techniques the skin dose is smaller than 2 mR and the gonadal doses lie around 0.1 mR for both male and female patients. An estimate of the dose burden from undesired radiation is appended. (orig.).
Apart from the vulnerability implied by the START II treaty, it will bear the burden of the general political opposition to the Yeltsin administration. START II will be seen as part of an overall Yeltsin-Andrei Kozyrev foreign policy that is under fire for selling out Russian national interests in Yugoslavia, the Persian Gulf, and elsewhere. This article discusses public opinion concerning START II, the cost of its implementation, and the general purpose of the treaty.
The upgraded CDF II detector has collected first data during the initial operation of the Tevatron accelerator in Run II. The simulation of the CDF electromagnetic and hadronic central and upgraded plug (forward) calorimeter is based on the Gflash calorimeter parameterization package used within the GEANT based detector simulation of the Run II CDF detector. We present the results of tuning the central and plug calorimeter response to test beam data.
PRESTO-II is a computer code developed to evaluate possible health effects from shallow land disposal of low level radioactive wastes. PRESTO-PREP is a data preprocessor that has been developed to expedite the formation of input data sets for PRESTO-II. PRESTO-PREP utilizes a library of nuclide and risk-specific data. Given an initial waste inventory, the code creates the radionuclide portion of the associated input data set for PRESTO-II. 2 references.
The purpose of this paper is to describe the embedded computer systems approach taken at Experimental Breeder Reactor II (EBR-II) for non-safety related systems. The hardware and software structures for typical embedded systems are presented The embedded systems development process is described. Three examples are given which illustrate typical embedded computer applications in EBR-II.
Angiotensin II (Ang II) is a key proapoptotic factor in fibrotic tissue diseases. However, the mechanism of Ang-II-induced cell death in endothelial cells has not been previously elucidated....Full Text Available
In Tarapur Atomic Power Station unit-3 and 4, which is 540 MWe pressurized heavy water reactor, tritium is produced in primary heat transport system and moderator system. Tritium is a major contributor to the internal dose. Internal dose contributes about 30% of the collective dose. Internal dose monitoring and its control are important to control the collective dose. Estimation of internal dose is done by analysis of bioassay samples of radiation workers. In a month, about 7000 bioassay samples are analysed for the internal dose assessment during normal operation, and about 12000 during the biennial shut down of the reactor. To enhance the sample preparation and counting performance, minimize the entry errors and reduce the processing time, barcode based label generation system was developed for the internal dose ...
Carbalkoxylation of vinyl electrophiles was investigated using platinum complexes. This reaction occurs in two steps: (a) carbonyl insertion of {sigma}-vinyl Pt(II) halides and (b) alcoholysis of vinylic acyl Pt(II) complexes. Alcoholysis of vinylic acyl Pt(II) triflate complexes is investigated kinetically. Vinylic acyl Pt(II) complexes were isolated and characterized. 51 refs., 5 figs., 6 tabs.
Critical experiments have been analyzed to verify a nuclear analysis system for fast reactors used in Japan Nuclear Cycle Development Institute (JNC). The experiments were performed in a collaboration work between JNC and the Institute of Physics and Power Engineering of Russia to dispose Russian surplus weapons plutonium, focusing on the effect of the introduction of uranium-plutonium mixed-dioxide (MOX) fuel and stainless steel reflector into the current BN-600 core that is comprised of UO_2 fuel and blanket. The analysis results agreed well with measured values on most of the nuclear characteristics. The accuracies are comparable to those obtained for the conventional MOX fueled fast reactors. It suggests that the JNC analysis system can analyze accurately nuclear characteristics in uranium fueled cores as well. A significant improvement was achieved on the sodium void reactivity by employing an ultra fine group cell calculation system. A change in adjoint ...
A surplus USN 40 mm ammunition can was subjected to a variety of tests. Pressure tests were carried out with nitrogen gas, followed by the venting of actual Li/SO/sub 2/ cells and batteries inside the can. A fire test was also conducted on a can packed with 10 each 10-cell batteries surrounded by vermiculite. Test results indicate the US Navy (USN) 40-mm ammunition can is suitable as a shipping container for Li/SO/sub 2/ batteries on passenger aircraft. To provide a further measure of safety, a sulfur dioxide getter was incorporated into the can. Studies indicated a commercial material, ASC carbon, is suitable for this purpose. The granular material was packaged in porous paper desiccant bags and placed in the can with the batteries and vermiculite. The batteries were vented inside the sealed can and the internal pressure monitored. Pressure returned to normal within several minutes, indicating that this arrangement should prevent sulfur dioxide (SO/sub 2/) gas ...
In 1980, Congress passed the energy security act which created the United States Synthetic Fuels Corporation. This entity was created to serve as a catalyst for the development of synthetic fuels projects by the private sector. Then what happened. Increased exploration in the United States stimulated by relaxation of price controls on oil produced an increase in reserves of these resources. Fuel conservation, combined with a reduced energy demand caused by a recession, significantly reduced our overall energy consumption and curtailed our imports of foreign crude oil. All of these factors combined have reduced the enthusiasm to invest in synthetic fuels plants, in spite of the fact that the difference between surplus and shortage is frighteningly thin. South Africa, compared to the U.S., is a small country. The Sasol Two and Sasol Three projects are equivalent to a U.S. investment of $400 billion, on a country size-by-size basis. It's hard to believe that ...
This paper highlights some of the conceptual and methodological problems involved in the compilation of statistics on economic aid to developing countries. Figures from the OECD Development Assistance Committee (DAC) and the Organization of Petroleum Exporting Countries (OPEC) member states are compared to point up problems in the interpretation of the statistics. One area of concern is the listing of funds provided by financial institutions located in the DAC countries. OPEC capital often forms a majority of such institutions; yet the figures do not measure the OPEC share of the capital nor its share of the risk borne in its provision of the loans. Another area of concern is bond purchases and subscriptions to syndicated loans by OPEC financial institutions in the financial markets of DAC countries. The flows in these instances, originating from OPEC sources, are merely channeled through the DAC financial markets. Based on origin and risk (borne exclusively by OPEC sources) these ...
The hydro-generators suffer during its operative useful life a combination of stresses of nature thermal, electric, mechanics and environmental. With the time, they are going losing the capacity to support those stresses and the power plants suffer, more and more frequently, undesirable stops for repair services and maintenance. In function of the high costs incurred with these stopped, the operation of the power plant can be economically impracticable. That unavailability of the generation for the electric system, it results in reduction of the reliability, burdening the politics of load ruling. The re-potentiation is a proposal that seeks to extend the useful life of hydro-generators, at the same time that it try to rescue the reliability and the readiness of the plant, with larger power. The power increase is usually made possible, or for the surplus of the hydro resources in excess, or for the reduction of the losses of all the components of the energy flow. ...
To investigate the future problem of oil field operation in the North Sea, the latest trend of the resources and development/production of the oil fields in the North Sea in British and Norwegian territories are outlined. Recoverable crude oil reserves, potential additional crude oil reserves, and undiscovered recoverable reserves of Britain, as well as probable total potential crude oil reserves in British continental shelf are put in order. Outlines of development and production of crude oil are described. The petroleum and gas development by Norway in 1996 is arranged, and outlines of the reserves, development, and petroleum/gas production are given. As the topics relating to the North Sea in 1996, reports are made on: the effective use of existing infrastructure surplus capacity; dealing with economic efficiency; challenge to abysmal development; applied instances of floating production; storage and offloading (FPSO) system to a small-size oil field in the ...
The developed electrical networks in the agricultural regions of the Estonian SSR make it possible to construct relatively powerful wind power plants at the sites of the most favorable wind conditions with small outlays for the power transmission lines. The wind power plant electricity can be used to electrify the production processes in agriculture, while the surplus can be supplied to the energy system. The inclusion of the wind power plants in the energy system makes it possible to improve the total generation of energy or reduce the consumption of fuel. With the efficient arrangement of the wind power plants, one can also reduce the energy losses during its transfer. Calculations indicated that in the coastal zones of the Estonian SSR, one can obtain specific power of 420-480 kW/km/sup 2/. For comparison it is indicated that the Estonian SSR in the agricultural regions now uses 8-12 kW/km/sup 2/. The wind-energy potential of the coastal regions and islands of ...
Users of pesticides may have waste or surplus quantities or spills for disposal. One alternative is to deactivate the pesticide at the handling site by using a straightforward chemical reaction. This option can be practical for those who use relatively small quantities of a large variety of pesticides, for example, greenhouse workers, small farmers, and agricultural researchers. This paper describes practical on-site methods for the disposal of spills or small waste quantities of five commonly used pesticides, Diazinon, Chlorpyrifos, Iprodione, 2,4-D, and Captan. These have been tested in the laboratory for the rate of disappearance of the pesticide, the degree of conversion to nontoxic products, the nature and identity of the products, the practicality of the method, and the ease of reproducibility. Methods selected were shown to be safe for the operator, reliable, and reproducible. Greater than 99% of the starting material had to be reacted under reasonable ...
For IGCC, the primary investment is too high due to the demand of high gasification efficiency. For PFBCC, the thermal efficiency is too low due to the relatively low turbine inlet temperature and the hot working medium of the gas turbine is not easy to clean. A new scheme is proposed for coal fired combined cycle to overcome the main drawbacks of IGCC and PFBCC. The research targets are developing a new cycle construction of coal fired combined cycle to raise the efficiency and reduce the primary investment. Actually, the new scheme is a synthesis of some existing proposals. It adopts partial gasification to reduce the primary investment of the gasification equipment. The un-gasified surplus solid is then fed to a pressurized fluidized bed boiler, but adopting Curtiss Wright type external combustion to lower the ash content in the working medium. The gas fuel from the partial gasifier is combusted in a top combustor to further increase the working medium ...
The aim of the study is to prepare ionic exchangers using the polymerization of unsaturated polyster with monomeric styrene units in a ratio of 60%: 40% respectively. The type of method involved in this preparation, is called An Emulsion Polymerization. Such type of polymerization was carried out by two techniques: chemical and irradiation techniques. The first techniques requires the formation of free radical monomers by use of methyl Ethy Ketone Peroxide capable of decomposing into free radicals upon heating, while the other technique involves the use of gamma rays (using Co-60 source) capable of activating monomers towards free radical formations. A number of very effective chemical parameters and physical factors were used and investigated throughout the reactions such as: dispersant matrix, viscosity, rate of mixing, and irradiation dose. Besides, the study has included the study of the rate of Resin Beads Swelling which is thought to be another important part ...
A method has been developed for calibration of CT-numbers to volumetric electron density distributions using tissue substitutes of known elemental composition and experimentally determined electron density. This information have been used in a dose calculation method based on photon and electron interaction processes. The method utilizes a convolution integral between the photon fluence matrix and dose distribution kernels. Inhomogeneous media are accounted for using the theorems of Fano and O'Connor for scaling dose distribution kernels in proportion to electron density. For clinical application of a calculated dose plan, a method for prediction of accelerator output have been developed. The methods gives the number of monitor units that has to be given to obtain a certain absorbed dose to a point inside an irregular, inhomogeneous object. The method for verification of ...
The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source ...
The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source ...
First, absorbed dose at entrance surface was measured in routine mammography. Secondly, a possibility of dose reduction after introduction of Fuji computed radiography (FCR) system was examined. In a total of 350 mammographic studies including craniocaudal and medilateral projections, average thickness of compressed breast was less than 4 cm and most frequently recorded absorbed dose was 0.2-0.3 cGy (200-300 mrad). Minimum dose to obtain clinically acceptable mammograms in FCR system was estimated by comparing image quality of routine versus reduced dose studies. It was concluded that absorbed dose could be reduced to 1/4 of routine dose without creating significant drawback in diagnosis. (author).
The subfornical organ is a major receptor area for one of the principal stimuli of thirst, the octapeptide, angiotensin II. In conscious water-sated rats, the authors examined the effects of intravenous infusion of angiotensin II on the rate of glucose utilization in the subfornical organ and in structures anatomically and functionally connected with it. Angiotensin II produced pressor and drinking responses and increased glucose utilization selectively in the subfornical organ and pituitary neural lobe and in no other brain structure. Treatment with the angiotensin II antagonist, sar1-leu8-angiotensin II, before intravenous administration of angiotensin II prevented metabolic stimulation of the subfornical organ and neural lobe. Captopril, an inhibitor of angiotensin-converting enzyme, reduced subfornical organ glucose metabolism to a level similar to that ...
Adsorptive removal of Pb(II) ions from aqueous solution onto a non-activated charcoal (CC) of oak wood origin was studied in comparison with an activated carbon of coal origin. The adsorption capacity for Pb(II) of the non-activated charcoal increased significantly with deceasing particle diameter, whereas the activated carbon (AC) exhibited approximately constant capacity for Pb(II) adsorption as a function of particle size. Adsorption to the ashes prepared from the non-activated charcoal and the activated carbon was also investigated to examine the role of mineral ash. Although the ash from the activated carbon did not show any Pb(II) adsorption, the ash from the charcoal was very effective for Pb(II) adsorption. Furthermore, Pb(II) was hardly adsorbed when the ash was removed from the non-activated charcoal by acid treatment. Based on the results, the ...
A survey to determine the annual genetically significant dose and mean bone-marrow dose to the Australian population from radiological procedures has been undertaken. For diagnostic radiology the following were carried out: determination of the frequency of a procedure; measurement of patient doses using TLD and processing of data and calculation of gonadal and bone-marrow doses.
In conveyor type irradiators, the movement of conveyor and the product boxes is not there until the source is fully in the irradiation position. In case the conveyor system fails the source must automatically be returned to its shielded storage vault. The dose received by the product during the movement of the source from or to the shield becomes significant if the total dose to be received by the product is small. A study has been carried out for evaluating the transient dose received by onions in the POTON irradiator. The results of the study are discussed in this paper. (author)
Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)
The uptake of "2"3"8U and "2"3"2Th in different parts of some selected plants used in traditional treatment of hypertension and diabetes in south-eastern Morocco (Errachidia area) has been studied using two different types of solid state nuclear track detectors (SSNTDs) LR-115 type II and CR-39. Plant uptake of radionuclides is one of many vectors for introduction of contaminants into the human food chain. Thus, it is critical to understand soil-plant relationships that control nuclide bioavailability. Soil concentrations of uranium ranged from 6.10 to 11.62 ppm, with a mean of 7.90 ppm. Soil concentrations of thorium ranged from 2.70 to 4.80 ppm, with a mean of 3.41 ppm. Mean uranium specific activities were 8.38 Bq kg"-"1 in root tissue, 5 Bq kg"-"1 in stem tissue and 6.02 Bq kg"-"1 in leaf tissue. Mean thorium specific activities were 2.53 Bq kg"-"1 in root tissue, 1.64 Bq kg"-"1 in stem tissue and 1.96 Bq kg"-"1 in leaf tissue. The transfer factors of "2"3"8U ...
''Paraquat lung'' which is complicated with paraquat poisoning has been a lethal pulmonary pathology presenting intra-alveolar fibrosis, but an effective therapy has not been developed so far. We hypothesized that the type II alveolar cells producing surfactant were damaged by paraquat which was actively accumulated through out the blood by alveolar epithelial cells. To prove this hypothesis, we examined the effect of an intratracheal administration of an artificial lung surfactant (surfacten, Mitsubishi Tanabe Pharma Corporation, Osaka) on mortality in a model of murine paraquat poisoning. Paraquat was given intramuscularly 3 days after the intratracheal surfactant administration. The mice used were C57BL/6J strain and Balb/C strain. The lethal dose, 50% (LD50), of paraquat was about 28 mg/kg in the C57BL/6J strain and about 9 mg/kg in the Balb/C strain, respectively. Mortalities of paraquat poisoning in both strains of mice improved ...
The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system resolution have hot been determined. The TNIF is currently being revamped to begin work with the ...
A Siemens Mevatron KV2 accelerator installed at the Royal Adelaide Hospital employs cylindrical solid-walled electron cones for some electron collimation. The cones being used at present result in treatment fields that do not always conform with the International Electrotechnical Commission (IEC) Standards (particularly at high energies). The aim of this project was to simulate the existing cones using Monte Carlo methods in order to evaluate potential cone modifications required to overcome the field irregularities. Simulations were performed using the EGS4 (Electron Gamma Shower version 4, distribution II) Monte Carlo code installed on a DEC Alpha workstation at the University of South Australia. To rigorously simulate the existing electron cones it was necessary to also simulate various components within the treatment head of the linear accelerator. Results of simulations for existing cones were found to be consistent with experimental data. (obtained from Royal ...
Background and purpose: We evaluate the feasibility of concomitant and adjuvant docetaxel combined with three-dimensional conformal radiotherapy (3D-CRT) and androgen deprivation in high-risk prostate carcinomas. Methods: Fifty men with high-risk localized prostate cancer (16), locally advanced (28) or very high-risk prostate cancer (6) were included. Seventy Gy were delivered on prostate and seminal vesicles in 35 fractions, concurrently with weekly docetaxel (20 mg/m"2). Three weeks after the completion of 3D-CRT, docetaxel was given for 3 cycles (60 mg/m"2), every 3 weeks. Patients had to receive LHRH agonist during 3 years. Results: The intent to treat analysis shows that four patients out of 15 stopped prematurely the chemotherapy due to grade 3-4 acute toxicity. In the per protocol analysis, 46 patients completed a full-dose chemoradiation regimen representing 413 cycles: five patients experienced a grade 3 toxicity, and 15 patients experienced a grade 2 ...
Boron Neutron Capture Therapy (BNCT) is a promising binary treatment modality for high-grade primary brain tumors (glioblastoma multiforme, GM) and other cancers. BNCT employs a boron-10 containing compound that preferentially accumulates in the cancer cells in the brain. Upon neutron capture by {sup 10}B energetic alpha particles and triton released at the absorption site kill the cancer cell. In order to gain penetration depth in the brain Fairchild proposed, for this purpose, the use of energetic epithermal neutrons at about 10 keV. Phase I/II clinical trials of BNCT for GM are underway at the Brookhaven Medical Research Reactor (BMRR) and at the MIT Reactor, using these nuclear reactors as the source for epithermal neutrons. In light of the limitations of new reactor installations, e.g. cost, safety and licensing, and limited capability for modulating the reactor based neutron beam energy spectra alternative neutron sources are being contemplated for wider ...
Non-first order (FO) kinetics models are of three types; second order (SO), general order (GO) and mixed order (MO). It is shown that all three of these have constraints in their energy level schemes and their applicable parameter values. In nature such restrictions are not expected to exist. The thermoluminescence (TL) glow peaks produced by these models shift their position and change their shape as the trap occupancies change. Such characteristics are very unlike those found in samples of real materials. In these models, in general, retrapping predominates over recombination. It is shown that the quasi-equilibrium (QE) assumption implied in the derivation of the TL equation of these models is quite valid, thus disproving earlier workers' conclusion that QE cannot be held under retrapping dominant conditions. However notwithstanding their validity, they suffer from the shortcomings as stated above and have certain lacunae. For example, the kinetic order (KO) parameter and ...
A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.
The aim of this research work has been the estimation of the stochastic risk for five barium examinations. The sample was the population attending the Radiological Service of the 'Nuestra Senora de la Victoria' University Hospital, who had been treated with some barium examinations, set in five different groups: oesophagus tract, oesophagus-gastric-duodenal tract, intestinal tract, enteroclysis and double enema. To estimate the stochastic risk, it is necessary to know the organ dose. This can be calculated from the dose-area product which allows us to determine the effective dose using software. The dose-area product is the most suitable quantity to measure in these types of examination. We have evaluated the contribution that each procedure provides to the genetically significant dose, somatically significant dose, collective effective ...
Voxel-based prescriptions of deliberately non-uniform dose distributions based on molecular imaging, so-called dose painting or theragnostic radiation therapy, require specification of a transformation...Full Text Available
Dose reconstruction is a process that re-creates the treatment-time dose deposited in a patient provided there is knowledge of the delivered energy fluence and the patient's anatomy at the time of treatment. A method for reconstructing dose is presented. The process starts with delivery verification, in which the incident energy fluence from a treatment is computed using the exit detector signal and a transfer matrix to convert the detector signal to energy fluence. With the verified energy fluence and a CT image of the patient in the treatment position, the treatment-time dose distribution is computed using any model-based algorithm such as convolution/superposition or Monte Carlo. The accuracy of dose reconstruction and the ability of the process to reveal delivery errors are presented. Regarding accuracy, a reconstructed dose distribution was compared with a ...
Experiments were conducted to determine the dose response of rat bladder urothelium to a range of different single and fractionated intravesicular doses of the carcinogen, N-methyl-N-nitrosourea (MNU)....Full Text Available
Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly different. Conclusion: The ...
The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).
The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).
Purpose:To investigate the clinical usage of dose verification of Helical Tomotherapy plans by using 2D-array ion chambers, and to develop an efficient way to validate the dose delivered...Full Text Available
The conventional IMRT planning process involves two stages in which the first stage consists of fast but approximate idealized pencil beam dose calculations and dose optimization and the second...Full Text Available
Organ and tissue doses and integral doses in patients due to diagnostic x-ray examinations of the chest and of the head will be presented. These data have been obtained by measuring the dose distributions in man phantoms by LiF-dosimetry. The data will be compared with data obtained by Monte-Carlo calculations. To obtain average organ doses for a special type of examination for the population or for a specified subpopulation in the variation of the exposure, data due to the different techniques used by the different radiologists has to be known. Such data will be presented. The results of the investigation will be discussed in connection with the concept of the 'somatic significant.
The purpose of this study is to explain the unplanned longitudinal dose modulations that appear in helical tomotherapy (HT) dose distributions in the presence of irregular patient breathing....Full Text Available
High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom. In this study, the humanoid phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the humanoid phantom were then compared with the treatment planning system for the dose verification. The humanoid phantom needs to be designed such that the dose distributions can be quantitatively evaluated thermoluminescent dosimeter (TLD) ...
An exact cosmological solution of Einstein's equations which has time-dependent rotation is presented. The t-constant sections are of Bianchi type II. The source of this geometry is a fluid which has not been thermalized. (Author).
Exposure of albumin to Cu(II) (10-100 microM) and ascorbate (0.1-2 mM) results in extensive molecular modifications, indicated by decreased fluorescence and chain breaks. The rate of utilization of...Full Text Available
ObjectivesThe updated Rome III criteria for pediatric functional gastrointestinal disorders (FGIDs) include new FGID categories and changes to the Rome II criteria...Full Text Available
Interleukin 2 (IL-2) and B-cell growth factors I and II (BCGF I and BCGF II) are lymphokines produced by T cells that play a major role in T- and B-cell cooperation. Peripheral blood lymphocytes from...Full Text Available
In this article are presented main results on electric potential investigations in stellarator/torsatron TJ-II and tokamak T-10 in a comparable regimes of device operation.
Aminopeptidase II, one of the two major aminopeptidases in the giant alga Chara australis, was partially purified. Its molecular weight was estimated to be about 80,000 by gel permeation...Full Text Available
New palladium(II) and platinum(II) complexes of saccharinate (sac), trans-[Pd(py)"2(sac)"2] (1), cis-[Pt(py)"2(sac)"2] (2), trans-[Pd(3-acpy)"2(sac)"2] (3) and cis-[Pt(3-acpy)"2(sac)"2] (4) (py=pyridine and 3-acpy=3-acetylpyridine) have been synthesized. Elemental analysis, UV-Vis, IR, NMR and TG/DTA characterizations have been carried out. The structures of 1-4 were determined by X-ray diffraction. The palladium(II) and platinum(II) ions are coordinated by two N-bonded sac ligands, and two nitrogen atoms of py or 3-acpy, forming a distorted square-planar geometry. The palladium(II) complexes (1 and 3) are trans isomers, while the platinum(II) complexes (2 and 4) are cis isomers. The mononuclear species in the solid state are connected by weak intermolecular C-H...O hydrogen bonds, C-H...@...
BackgroundThe binding of peptide fragments of antigens to class II MHC is a crucial step in initiating a helper T cell immune response. The identification of such peptide epitopes...Full Text Available
The aim of this article was to investigate the interactions of metal cations in aqueous solutions with the biomass of the freshwater macroalga Vaucheria sp. This problem is important when elaborating new applications of biosorption, e.g. the production of mineral feed additives for livestock from the biomass of algae enriched with microelement ions. Potentiometric titration was applied as a quick and cheap screening test to search for new efficient biosorbents. It revealed a variety of functional groups capable of cation exchange on the macroalgal surface, including carboxyl, phosphate, hydroxyl or amino groups. Fourier transform infrared spectroscopy on natural and chromium-loaded Vaucheria sp. confirmed that carboxyl groups played a dominant role in the biosorption. The study also showed that Ca(II), Na(I), K(I), and Mg(II) ions were released from the biomass after biosorption of Cu(II), Mn(II), ...
BackgroundPromoter region plays an important role in determining where the transcription of a particular gene should be initiated. Computational prediction of eukaryotic Pol II promoter...Full Text Available
Rotazyme II, which is a shorter version of Rotazyme (less than 3 h), was compared with electron microscopy and Rotazyme for sensitivity and specificity on 229 human stool specimens. Compared with electron...Full Text Available
The biosorption of lead (II) and copper (II) ions, single component and binary systems, by dried P. putida was investigated in a batch system. The effects of initial pH, temperature, initial single and binary mixture concentrations on the biosorption kinetics and equilibrium uptake of each component, both single and binary mixtures were investigated. The bacterial biomass exhibited the highest single and binary lead (II) and copper (II) ions uptake capacity at 25 and 30 deg. C, respectively, the initial pH value of 5.5 and at the initial metal ions concentration of 100 mg dm{sup -3}. The Freundlich and Langmuir adsorption models were used for the mathematical description of the biosorption equilibrium and isotherm constants were evaluated at different temperatures. Adsorption data were well described by the Langmuir model, although they could be modeled by the Freundlich equation. The thermodynamics ...
BackgroundPerfluorocarbons (PFC) are used to improve gas exchange in diseased lungs. PFC have been shown to affect various cell types. Thus, effects on alveolar type II (ATII) cells...Full Text Available
ATP-binding cassette A3 (ABCA3) is a lipid transport protein required for synthesis and storage of pulmonary surfactant in type II cells in the alveoli. Abca3 was conditionally deleted...Full Text Available
Cytokinesis in animal and fungal cells utilizes a contractile actomyosin ring (AMR). However, how myosin II is targeted to the division site and promotes AMR assembly, and how the AMR coordinates with...Full Text Available
Anaerobic reactions of Rhus vernicifera laccase and its type-2 copper-depleted derivatives with hexacyanoferrate(II) were investigated by absorption and e.s.r. spectroscopy. When native laccase was...Full Text Available
Photobilirubin II, a stereoisomer of bilirubin, binds to human serum albumin at a single binding site (K = 2.2 x 10(6)M-1), presumably the high-affinity bilirubin-binding site. Binding in the secondary...Full Text Available
The identification of MHC class II restricted peptide epitopes is an important goal in immunological research. A number of computational tools have been developed for this purpose, but there is a lack...Full Text Available
ii) Flammability: (iii) A capacity to oxidise: (iv) Corrosiveness: (v) Toxicity (including chronic ...an explosion or fire: (d) For substances with corrosive properties: (i) To reduce the ...likelihood of any unintended corrosion:(ii) To control the adverse effects of any corrosion:
... Screening Adjudication Monitoring Applicants of Information Behavior II I Conducting Investigations ... Applicants of Information Behavior Conducting ...
Titanate nanotubes were hydrothermally synthesized and their adsorption performances for lead(II) ion removal were studied. The results showed that titanate nanotubes ruptured in the adsorption process resulting in two distinct adsorption stages, thus achieving a maximum adsorption capacity of 3.752mmolg^-^1 of lead(II). Furthermore, it was found that the regeneration of titanate nanotubes loaded with the lead(II) ions can be readily achieved using the saturated EDTA disodium salt aqueous solution, thereby avoiding the trouble of disposal of adsorbent. The adsorption mechanism was also discussed in detail.
The interaction between N-donor adsorbates such as ammonia and pyridine with Cu(II)-exchanged montmorillonite, beidellite, flourohectorite into smectite clays has been studied by electron spin resonance. Cu(II) cations exchanged into smectites coordinate five ammonia or pyridine molecules in beidellite, four ammonia of pyridine molecules in hydroxyhectorite. Thus, the Cu(II) cations bound to the interior surfaces of these smectite clays constitute strong Lewis acid sites. 26 refs., 7 figs., 1 tab.
CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey on CT practice. Three different ...
We report the of the existence of RV Tauri stars in the Large Magellanic Cloud (LMC). This class of variable star has hitherto been unidentified in the Magellanic Clouds. In light and color curve behavior the RV Tauri stars appear to be an extension of the Type II Cepheids to longer periods. A single period-luminosity-color relationship is seen to describe both the Type II Cepheids and the RV Tauri stars in the LMC.
Incorporation of /sup 32/P from (gamma-32P)ATP into tyrosine residues of the insulin-like growth factor (IGF)-II receptor was observed in a Triton X-100-insoluble fraction of rat adipocyte plasma membranes. IGF-II receptor phosphorylation proceeded to a stoichiometry of approximately 0.5 mol of phosphate/IGF-II binding site after 10 min of incubation at 4 degrees C. A Km for ATP of 6 microM was calculated for this phosphorylation reaction. Addition of IGF-II caused an approximately 2-fold increase in tyrosine phosphorylation of the IGF-II receptor in this preparation. In contrast, phosphorylation of angiotensin II by the Triton X-100 washed membranes was not stimulated by IGF-II. Incubation of purified receptor immobilized on IGF-II agarose or of receptor-enriched low density microsomal membranes with (gamma-32P)ATP did ...
Fragrance mix II (FM II) is a relatively new screening marker for fragrance contact allergy. It was introduced in the patch test baseline series in Denmark in 2005 and contains six different fragrance chemicals commonly present in cosmetic products and which are known allergens.
Fatty acid biosynthesis is crucial for all living cells. In contrast to higher organisms, bacteria use a type II fatty acid synthase (FAS II) composed of a series of individual proteins, making...Full Text Available
Some acylhydrazine derived ONO donor Schiff bases and their Co(II) and Ni(II) complexes have been prepared having the same metal ion (cation) but different anions. These synthesized metal(II) complexes have been characterized on the basis of their elemental analyses, magnetic moment, molar conductance, and IR and electronic spectral data. All of the Schiff base ligands function as tridentates and the deprotonated enolic form is preferred for coordination. In order to evaluate the effect of anions on the bactericidal activity, these synthesized complexes, in comparison to the uncomplexed Schiff bases have been screened against bacterial species., Escherichia coli, Staphylococcus aureus and Pseudomonas aeruginosa and the results are reported. PMID:18475936
High-temperature LiCl-KCl molten salt medium provides an efficient way to produce the paramagnetic Eu(II) ion to be magnetically diluted into a diamagnetic host medium. Eu(II) was formed by a dissolution and an auto-reduction processes in a high-temperature LiCl-KCl eutectic melt at 723 K by using Eu{sub 2}O{sub 3} as a starting material. By using EPR and luminescence spectroscopic method, we studied the nature of the magnetically isolated paramagnetic Eu(II) ion diluted in a LiCl-KCl medium. With the aid of these spectroscopic tools, it was found that stable Eu(II) species was formed spontaneously at 723 K under anaerobic conditions. EPR and luminescence spectroscopy provided detailed information regarding the nature of the europium ion in a molten salt.
High-temperature LiCl-KCl molten salt medium provides an efficient way to produce the paramagnetic Eu(II) ion to be magnetically diluted into a diamagnetic host medium. Eu(II) was formed by a dissolution and an auto-reduction processes in a high-temperature LiCl-KCl eutectic melt at 723 K by using Eu_2O_3 as a starting material. By using EPR and luminescence spectroscopic method, we studied the nature of the magnetically isolated paramagnetic Eu(II) ion diluted in a LiCl-KCl medium. With the aid of these spectroscopic tools, it was found that stable Eu(II) species was formed spontaneously at 723 K under anaerobic conditions. EPR and luminescence spectroscopy provided detailed information regarding the nature of the europium ion in a molten salt.
High-temperature LiCl-KCl molten salt medium provides an efficient way to produce the paramagnetic Eu(II) ion to be magnetically diluted into a diamagnetic host medium. Eu(II) was formed by a dissolution and an auto-reduction processes in a high-temperature LiCl-KCl eutectic melt at 723K by using Eu2O3 as a starting material. By using EPR and luminescence spectroscopic method, we studied the nature of the magnetically isolated paramagnetic Eu(II) ion diluted in a LiCl-KCl medium. With the aid of these spectroscopic tools, it was found that stable Eu(II) species was formed spontaneously at 723K under anaerobic conditions. EPR and luminescence spectroscopy provided detailed information regarding the nature of the europium ion in a molten salt.
We determined the chromosomal localization and structure of the gene encoding human type II inosine 5{prime}-monophosphate dehydrogenase (IMPDH, EC 1.1.1.205), an enzyme associated with cellular proliferation, malignant transformation, and differentiation. Using polymerase chain reaction (PCR) primers specific for type II IMPDH, we screened a panel of human-Chinese hamster cell somatic hybrids and a separate deletion panel of chromosome 3 hybrids and localized the gene to 3p21.1{yields}p24.2. Two overlapping yeast artificial chromosome clones containing the full gene for type II IMPDH were isolated and a physical map of 117 kb of human genomic DNA in this region of chromosome 3 was constructed. The gene for type II IMPDH was localized and oriented on this map and found to span no more than 12.5 kb.
In this study we compared various maturity dependent aromatic, steroid and triterpenoid hydrocarbon ratios in bitumens that are freely extractable from sedimentary rocks (Bitumen I) with those in second extracts that comprised hydrocarbons closely associated with the kerogen/mineral matrix (Bitumen II). Bitumen II was released through kerogen isolation and demineralisation using HCl and HF/H3BO3. The samples studied, although of similar age, come from different localities. They represent a range of facies and two kerogen types (II and III), and all were deposited under marine conditions. The results show that the more stable b isomers of methylnaphthalene (MN) and methylphenanthrene (MP) are relatively more abundant in Bitumen II. The difference between the methylnaphthalene ratio (MNR) of...
A total dose hardening treatment is applied to SIMOX buried oxides. Total ionizing dose radiation testing is performed on fully-depleted transistors fabricated on both hardened and non-hardened substrates. At 200 krads x-ray dose, the front gate shift is reduced from -0.7 to -0.2 V for FETs built on the hardened wafers.
The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).
Dose-dependent behavior of the infrared stimulated luminescence (IRSL) decay from NaCl has been studied experimentally using only one aliquot irradiated with a range of 2-200 Gy {beta}-radiation doses. It was observed that the maximum IRSL intensity has not changed by an increase in dose though the total intensity increased as expected. Considering the possible implications of our findings for dosimeter, the results were compared with the other studies and discussed.
Electron spin resonance (ESR) dosimetry of irradiated chicken legs is based on the additive dose or the calibration curve methods. In both cases the practical assumption is made that the behaviour of the chicken bone does not depend on factors such as temperature during irradiation, storage conditions and dose rate. So the aim of the present work was to investigate to what extent the above mentioned factors could influence the post-irradiation dose assessment using the ESR technique. (author).
The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different.
The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different. (orig.).
Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. ...
Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. ...
Depth dose distributions for protons in the energy range from 2 to 600 MeV have been calculated by Monte Carlo and analytical methods. The dependence on energy of Maximum Dose Equivalent (MDE), quality factor and isotropic factor recommended for practical use are presented. The problems connected with regulation of maximum permissible proton fluxes are discussed. (author).
Carcinogenesis is now generally recognized to be an important detrimental effect in man after low dose irradiation. The carcinogenic action of ionizing radiation is clearly demonstrated after exposure to relatively high doses (in excess of 0.5 Gy) but for lower dose levels reliable direct observations are not available. With the introduction of special protocols for the performance of large scale screening programs by mammography the average absorbed dose in glandular tissue in the average breast can be restricted to a value of 3 mGy per mammogram. The risk for tumor induction after exposure to these low doses can never be established from human epidemiology. In order to investigate the risk of repeated exposure to small dose of ionizing radiation the induction of mammary tumors has been investigated in rats of the WAG/Rij strain after single and fractionated ...
Single doses of lead (trace to 445 mg/kg) were administered per os to suckling and adult mice. Both groups exhibited dose-independent lead retention when doses of 4 to 445 mg/kg were administered. However, developmental differences in the fraction of initial dose (FID) retained were evident for all doses administered. A much larger FID was retained in both age groups following administration of carrier-free /sup 203/Pb. The results are consistent with a mechanism of gastrointestinal lead absorption comprising two or more processes. Developmental differences were also observed in organ lead concentration relative to whole body concentration for kidneys, skull and brain 6 days following lead administration. Lead retentions (relative to whole body retention) in brain and in bone were linearly related to dose of lead administered in both suckling and adult age ...
Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to ...
Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to ...
Objective: To investigate the feasibility of low-dose single-slice helical CT in pulmonary CT scan and evaluate the clinical application. Methods: Thirteen cases were selected out of 132 cases, in which low-dose (50mAs) single-slice helical CT scan of chest was performed. This set of cases included 7 cases of multiple metastatic nodules; 3 of solitary pulmonary, nodule; and 3 of pulmonary patchy lesions. Regular dose (170mAs) CT scan was also performed on all those patients. The regular dose and low dose CT scan were compared on sensitivity of detecting the lesions; the performance in demonstrating the details of the abnormalities; and the capability of revealing the segmental bronchi as well. Results: The same number and size of the pulmonary nodules were revealed with scan modalities loaded with different doses. No significant difference in demonstrating the ...
An attempt was made to quantify the radiation risk of diagnostic radiology. After a general introduction of terms as radiation damage, radiation risk and effective dose equivalent, based on publications of the ICRP, somatic dose indexes were computed for several radiologic investigations, that comprise organ doses committed to red bone marrow, lung, female breast and thyroid with and without considering the rest of the body. The dose for the rest of the body was assumed to be equal to the dose received by the red bone marrow, that is also distributed over the whole body. Neglecting the exposure of the rest of the body resulted in an insignificant increase in the estimated somatic risk, with its experimental determination not being necessary. (author).
Full text: An adaptive response is a decreased biological effect induced by a priming radiation dose given prior to a challenge dose. Adaptive responses contradict the linear-nothreshold model of risk estimation. The pKZ1 mouse chromosomal inversion assay is an extremely sensitive assay for studying the mutagenic effect of low dose radiation. A non-linear dose response for chromosomal inversion has been observed in pKZ1 spleen and prostate after a single whole body irradiation with doses between 1?Gy and 10mGy. Doses between 5-10?Gy resulted in an induction in inversions and doses between 1-10mGy resulted in a reduction below endogenous inversion frequency. These results suggest that doses in the 1-10 mGy range cause host responses which overcompensate by not only preventing inversions that would normally occur as a ...
Irradiation of the human body in diagnostic X-ray procedures results in different absorbed doses in the various body organs. A somatic dose index in formulated by applying the relative sensitivity of the human to each of the most important somatic effects and utilizing the absorbed dose in the affected organs. This quantity is used to convey a cumulative somatic impact and is computed for common radiographic views in diagnostic radiology as a function of beam quality for a nominal IR entrance exposure. Using typical X-ray beam qualities and exposures, the frequency of the various radiographic views that make up an examination and the frequencies of the various examinations in the national population, illustrative examples of the application of the somatic dose index are presented. (author).
The palladium(II) and platinum(II)complexes(where, (M(L){sub 2}X{sub 2}), M=Pd(II), Pt(II); L=isoxazole (isox), 3, 5-dimethylisoxazole(3, 5-diMeisox), 3-methyl, 5-phenylisoxazole(3-Me, 5-Ph-isox), and 4-amino-3, 5-di-methylisoxazole (4-ADI); X=Cl, Br) with isoxazole and its derivatives were investigated on antitumor activity by MM2 and EHMO calculation. Because for all the complexes the {sigma}MO energy level (E{sub {sigma}}{sub (M-X)} between d{sub x}{sup 2}{sub -y}{sup 2} orbital of central metal and p{sub x} orbital of halogen atom is less than {sigma}MO energy level E{sub {sigma}}{sub (M-N)} between d{sub x}{sup 2}{sub -y}{sup 2} orbital of central metal and p{sub x} orbital of N atom, without exception. And judging, from the lower E{sub {sigma}}{sub (M-X)} value in trans, the bonding strength was found to be weaker in trans isomer than in cis. For the Pd(II) and ...
Varying coordination modes of the Schiff base ligand H"2L [5-methyl-1-H-pyrazole-3-carboxylic acid (1-pyridin-2-yl-ethylidene)-hydrazide] towards different metal centers are reported with the syntheses and characterization of four mononuclear Mn(II), Co(II), Cd(II) and Zn(II) complexes, [Mn(H"2L)(H"2O)"2](ClO"4)"2(MeOH) (1), [Co(H"2L)(NCS)"2] (2), [Cd(H"2L)(H"2O)"2](ClO"4)"2 (3) and [Zn(H"2L)(H"2O)"2](ClO"4)"2 (4), and a binuclear Cu(II) complex, [Cu"2(L)"2](ClO"4)"2 (5). In the complexes 1-4 the neutral ligand serves as a 3N,2O donor where the pyridine ring N, two azomethine N and two carbohydrazine oxygen atoms are coordinatively active, leaving the pyrazole-N atoms inactive. In the case of complex 5, each ligand molecule behaves as a 4N,O donor utilizing the pyridine N, one azomethine N...
The biosorption characteristics of Pb(II) and Cd(II) ions from aqueous solution using the green alga (Ulva lactuca) biomass were investigated as a function of pH, biomass dosage, contact time, and temperature. Langmuir, Freundlich and Dubinin-Radushkevich (D-R) models were applied to describe the biosorption isotherm of the metal ions by U. lactuca biomass. Langmuir model fitted the equilibrium data better than the Freundlich isotherm. The monolayer biosorption capacity of U. lactuca biomass for Pb(II) and Cd(II) ions was found to be 34.7 mg/g and 29.2 mg/g, respectively. From the D-R isotherm model, the mean free energy was calculated as 10.4 kJ/mol for Pb(II) biosorption and 9.6 kJ/mol for Cd(II) biosorption, indicating that the biosorption of both metal ions was taken place by chemisorption. The calculated thermodynamic parameters ({delta}G{sup o}, ...
In 1978 the Marshall Islands Radiological Safety Program was organized to perform radiation measurements and assess radiation doses for the people of the Bikini, Enewetak, Rongelap and Utirik Atolls. One of the major field components of this program is whole- body counting (WBC). WBC is used to monitor the quantity of gamma- emitting radionuclides present in individuals. A primary objective of the program was to establish {sup 137}Cesium body contents among the Enewetak, Rongelap and Utirik populations. {sup 137}Cs was the only gamma-emitting fission radionuclide detected in the 1,967 persons monitored. {sup 137}Cs body burdens tended to increase with age for both sexes, and were higher in males. The average {sup 137}Cs dose Annual Effective Dose for the three populations was as follows: For Enewetak, the dose was 22{+-}4 {mu}Sv. For Utirik, the dose was 33{+-} 3 {mu}Sv. Since 1985 ...
The medical applications of radiation comprise three main fields namely: Diagnostic Radiology, Radiotherapy and Nuclear Medicine. With the new weighting factors of ICRP (IC91a) the effective dose due to medical applications can be established. I is common to separate the effective dose into the genetic part and the somatic part, SED. In dealing with gonad doses it is important to account for the age of the person at the time of exposure as this will influence the number of children still to be expected from that person. The resulting dose will then be called the genetically significant dose, GSD. In a similar fashion this age factor will be important in considering the chance of tumor induction. The age of patients differs considerably from the average age of the general population. This age difference has to be accounted for if a comparison is to be made with other sources of ...
Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 {mu}Sv/y, collective dose: 1 man{center_dot}Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 {mu}Sv per year and 0.166 man{center_dot}Sv per year about H-beam, and 158 {mu}Sv per year and 0.468 man{center_dot}Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance ...
Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 #mu#Sv/y, collective dose: 1 man#centre dot#Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 #mu#Sv per year and 0.166 man#centre dot#Sv per year about H-beam, and 158 #mu#Sv per year and 0.468 man#centre dot#Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance ...
By applying the linear-dose effect relation, the weighting factors for total risks recommended by IRCP can be transformed to weighting factors for somatic effects. Another weighting factor Msub(s) has to be used which takes into account the dependence of the latent period for occurrence of malignant disease and the variation of the incidence with time. On this basis a somatically significant dose equivalent can be defined as 'the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by the various individuals', and an approximation has been derived for this. Tables are presented of the somatic effective dose equivalents calculated for different x-ray examinations for various organs and tissues. The S.E.D. equivalents have also been calculated for ...
The determination of the dose to organs from diagnostic x rays has become important because of reports of radiation injury to patients from fluoroscopically guided interventional procedures. We have modified a convolution/superposition-based treatment planning system to compute the dose distribution for kilovoltage beams. We computed lung doses using this system and compared them to those calculated using the CDI3 organ dose calculation program. We also computed average lung doses from a simulated radiofrequency ablation procedure and compared our results to published doses for a similar procedure. Doses calculated using this system were an average of 20% lower for AP beams and 7% higher for PA beams than those obtained using CDI3. The ratio of the average dose to the lungs to the skin dose from the ...
Finding innovative ways to reduce waste streams generated at US Department of Energy (DOE) sites by 50% by the year 2000 is a challenge for DOE`s waste minimization efforts. A team composed of members from several DOE facilities used the quality tool known as benchmarking to improve waste minimization efforts. First the team examined office waste generation and handling processes at their sites. Then team members developed telephone and written questionnaires to help identify potential ``best-in-class`` industry partners willing to share information about their best waste minimization techniques and technologies. The team identified two benchmarking partners, NIKE, Inc., in Beaverton, Oregon, and Microsoft, Inc., in Redmond, Washington. Both companies have proactive, employee-driven environmental issues programs. Both companies report strong employee involvement, management commitment, and readily available markets for recyclable materials such as white paper and nonwhite assorted ...
Statements about the dynamic processes of uptake, transport, and deposition of Ca and Mg in norway spruce and Scots pine are made in this paper. Concerning the storage of these elements it is shown that there are great differences in their functional importance in cell metabolism. There is evidence that the role of Mg in enzyme and protein metabolism is of far greater significance for the understanding of Mg-deficiency symptoms than its function as the central atom of the chlorophyll complexes. In regard to the transport and especially to the incorporation of Ca into the needles differences between species were evident, expressing the special status of pine among the gymnosperms. With increasing needle age an accumulation of Ca-oxalate crystals, which are physiologically inert, could be proved for the studied conifers. This was interpreted as a 'detoxication' from surplus Ca to hold constant the level of the physiologically active fraction. Accordingly, the low ...
The strategy for management of the Oak Ridge National Laboratory`s (ORNL) radioactively contaminated liquid waste was reviewed in 1991. The latest information available through the end of 1990 on waste characterization, regulations, US Department of Energy (DOE) budget guidance, and research and development programs was evaluated to determine how the strategy should be revised. Few changes are needed to update the strategy to reflect new waste characterization, research, and regulatory information. However, recent budget guidance from DOE indicates that minimum funding will not be sufficient to accomplish original objectives to upgrade the liquid low-level waste (LLLW) system to comply with the Federal Facilities Agreement, provide long-term LLLW treatment capability, and minimize environmental, safety, and health risks. Options are presented that might allow the ORNL LLLW system to continue operations temporarily, but they would significantly reduce its capabilities to handle ...
The strategy for management of the Oak Ridge National Laboratory`s (ORNL`s) radioactively contaminated liquid waste was reviewed. The latest information on waste characterization, regulations, US Department of Energy (DOE) budget guidance, and research and development programs was evaluated to determine how the strategy should be revised. Few changes are needed to update the strategy to reflect new waste characterization, research, and regulatory information. However, recent budget guidance from DOE indicates that minimum funding will not be sufficient to accomplish original objectives to upgrade the liquid low-level waste (LLLW) system to be in compliance with the Federal Facilities Agreement compliance, provide long-term LLLW treatment capability, and minimize Environmental Safety & Health risks. Options are presented that might allow the ORNL LLLW system to continue operations temporarily but significantly reduce its capabilities to handle emergency situations, provide treatment ...
Two electroactive polymeric arylene bisimides, namely poly[(4,7,10-trioxatrideca-1,13-diyl)-(1,4,5,8-naphthalenetetracarboxylic bisimide-N,N'-diyl)] and its perylene analogue - poly[(4,7,10-trioxatrideca-1,13-diyl)-(3,4,9,10-perylenetetracarboxylic bisimide-N,N'-diyl)] have been synthesized and studied by cyclic voltammetry, UV-vis-NIR as well as Raman spectroeletrochemistry. Contrary to low molecular weight arylene bisimides, which show a clear two electron, double-step electrochemical reduction (neutral form to radical anion and from radical anion to dianion), in the synthesized polymers multielectron transfers are observed, accompanied with a strong electrochromic effect. However, as probed by cyclic voltammetry, their first reduction step is retarded and covers a wider potential range. We attribute this effect to macromolecular nature of the compounds being reduced and their structural inhomogeneity caused by ?-stacking induced nanoaggregation of bisimide segments of the polymer ...
Discussions regarding the use of wood fuels for commercial energy production in the Netherlands began in the 1990's. The main reasons for using wood fuel are: the political demand for using renewable energy, the need to reduce CO_2 emissions, and the lack of markets for surplus timber. Only 10 % of the area of Holland is forested. Therefore, early thinning and cleaning are important management tools for improving growth and producing better quality timber. The energy potential from early thinning and plantation cleaning could be between 400 000 and 570 000 dry tons annually. The Netherlands has not experience in harvesting energy wood. However, through the International Energy Agency/Bioenergy Agreement, knowledge gained in other countries, especially Denmark, Sweden and Finland, is being transferred to Holland. In 1996, there have been made field tests with Danish equipment. Although there are few technical barriers to wood fuel in the Netherlands, the economics ...
The thesis explains the development of a mass spectrometerical isotope dilution analysis (MS/DA) for determining trace amounts of Tc. The Tc-97 isotope has been prepared by in-core irradiation of Ru of natural isotopic composition, and used as the indicator isotope. For separation of Tc-97 from the Ru matrix, a method has been developed to quantitatively separate Tc-97 from a high Ru surplus. For determining the isotope ratio for the MS/DA, a mass spectrometrical measuring technique has been found which allows reproducible measurement of the Tc-99/Tc-97 isotope ratio. Positive and, for the first time, also negative thermoionisation has been used as a method of selective ionisation of Tc. The applicability of the MS/DA for Tc trace analysis has been verified using two Al foils doped with Tc-99 or Mo-98, respectively. These have been irradiated in a nuclear reactor, the irradiation of Tc-99 yielding Ru-100, and irradiation of Mo-98 Tc-99. The determination of the ...
As part of The International Northern Sea Route Programme (INSROP), Subprogram III, Trade and Commercial Shipping, a study has been made concerning seaborne export of liquefied petroleum gas (LPG) from the Northern Russia, especially the West Siberian fields in Tyumen. The main purpose of the total project III.0703, part 2 and this study is to evaluate the economic viability of seaborne export from this area to the European region, mainly with the use of a special ice-strengthened LPG vessel, constructed and designed for such seaborne operations. This study concentrates on both seaborne LPG transportation, the demand and supply for seaborne LPG in the world and marine transportation of LPG from the West Siberian fields. Another purpose is to see which regions are potential exporters, importers and buyers of seaborne export of LPG from Tyumen. Currently large quantities of liquefied gas are flared off at the West Siberian fields due to insufficient infrastructure, lack of modern ...
This report describes the progress made during this reporting period of a two year project to demonstrate that the air pollution from a traveling grate stoker being used to heat water at a central heating plant in Krakow, Poland can be reduced significantly by (1) substituting the unwashed, unsized coal currently being used with a mechanically cleaned, double-sized stoker fuel and by (2) optimizing the operating parameters of the stoker. It is anticipated that these improvements will prove to be cost effective and hence be adopted by the other central heating plants in Krakow and indeed, throughout Eastern European cities where coal continues to be the primary source of fuel. EFH Coal Company has formed a partnership with two Polish institutions -- MPEC, a central heating company in Krakow, and Naftokrak-Naftobudowa, preparation plant designers and fabricators, for the execution of this effort. The washability data from a 20mm x 0.5mm size fraction of raw coal from the Nikwa Modrejow ...
This report describes the progress made during the second Quarter of a two year project to demonstrate that the air pollution, from a traveling grate stoker being used to heat water at a central heating plant in Krakow Poland, can be reduced significantly by replacing the unwashed, unsized coal now being used with a mechanically cleaned, double sized stoker fuel and by optimizing the operating parameters of the stoker. It is anticipated that these improvements will prove to be cost effective and hence be adopted in the other central heating plants in Krakow and indeed throughout Eastern European cities where coal is the primary source of heating fuel. EFH Coal Company has formed a partnership with two Polish institutions -- MPEC a central heating company in Krakow and Naftokrak-Naftobudowa, preparation plant designers and fabricators for this effort. The washability data from a 20mm x 0.5mm size fraction of raw coal from the Staszic Mine were evaluated. The data show that the ash ...
The basic feature in the functional ecology of any mire ecosystem is retardation of the effective decay of organic material resulting in a conspicuous accumulation of plant debris as peat overtime. The carbon accumulation process is slow, and climatic change may have an impact on the carbon cycle of peatlands, therefore, it has been of interest to study the rate of carbon accumulation by geological methods from dated peat strata. The approach is hampered by several facts. First, the mires vary enormously as to their vegetation and hydrology and hence their production and decay properties. It follows that a great number of study sites are needed. Second, the peat in mires expands both vertically and laterally, and this requires a spatial reconstruction of carbon accumulation within a mire basin. Third, simple geological methods cannot account for the actual rate of carbon accumulation in peat, and finally, an additional carbon sink in the mire ecosystems can be the mineral subsoil ...
For the step-and-shoot intensity-modulated radiation therapy (IMRT) technique, the combination of high dose rate, multiple beam segments and low dose per segment can lead to significant differences between the planned dose and the dose delivered to the patient. In this technique, a dose delivery inaccuracy known as the 'overshoot' effect is caused by the dose servo control system. This typically occurs in the first and last beam segments and causes an over- and underdose, respectively. Some dose positional error in the segment sequence is also possible there. Commercial ionization chambers (RK-type) and radiographic Kodak films were used for the measurements. The reported results were obtained using the Pinnacle{sup 3}-V6.2 treatment planning system and a Varian Clinac 21 EX linear accelerator equipped with a 120-leaf ...
Objective: To develop software for assessment of dose to thyroid gland in emergencies resulting in the release of radioiodine. Methods: Based on procedures for thyroid monitoring and dose assessment introduced in IAEA publications (IAEA-TECDOC-1092 and EPR-MEDICAL-2005), a software was developed with Visual Basic 6.0 program to computerized the methods of thyroid dose estimation. Results: The intake of radioiodine and committed equivalent dose to thyroid could be estimated rapidly and accurately with the present software. Conclusion: The present software provide a practical and rapid tool for estimating thyroid doses received in emergencies resulting in the release of radioiodine by emergency workers and members of public, which is necessary for recommendation of further actions. (authors)
The basic relationships of the convolution/superposition dose calculation technique are reviewed, and a modelling technique that can be used for obtaining a satisfactory beam model for a commercially available convolution/superposition-based treatment planning system is described. A fluence energy spectrum for a Co-60 treatment machine obtained from a Monte Carlo simulation was used for modelling the fluence spectrum for a Rokus M machine. In order to achieve this model we measured the depth dose distribution and the dose profiles with a Wellhofer dosimetry system. The primary fluence was iteratively modelled by comparing the computed depth dose curves and beam profiles with the depth dose curves and crossbeam profiles measured in a water phantom. The objective of beam modelling is to build a model of the primary fluence that the patient is exposed to, which can then be used for the ...
When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).
When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).
Lifetime of minority charae carriers in the Si and Ge p-n unctions has been measured by pulse method of conductivity modulation of base. Its dependence on the X-ray radiation dose has been investigated. Dependence of current transmission coefficients on the dose has been measured and their sharp decrease at low doses and the following saturation at high doses have been observed. Linear dependence of lifetime on X-ray radiation dose has been obtained. Resulting from the comparison of regularities of the change of lifetime due to current characteristics, it has been shown that X-ray radiation leads to the formation of the surface defects, influencing the change of current characteristics as well as to stationary structural defects, causing the decrease of lifetime of the charge carriers with the increase of X-ray radiation dose.
The ECOSYS model is used to estimate ingestion dose in the ARGOS and RODOS decision support systems for nuclear emergency management. It is recommended that nation-specific values for several parameters are used in the model. However, this is generally overlooked when the systems are used in practice. We have estimated first year ingestion doses in two scenarios with wet and dry deposition of 137Cs, using the ECOSYS model. We calculated doses for each country using national dietary data while keeping all other parameters at their default values. These dose calculations were then used to estimate the variation in ingestion doses resulting from the variation in the diets only. The dietary data demonstrated that the average consumption of milk, meat and vegetables varied by a factor of 2-4 am...
This study investigated dose to bone tissue in electron beam therapy. Measurements were made using films and thermoluminescent dosimeters in a polystyrene phantom containing bone inhomogeneity for 15-MeV, 12-MeV, and 9-MeV electron beams. An increase in dose of approximately 18%, 12%, and 11%, for the three electron energies respectively, relative to the dose in polystyrene, was found for bone material having an electron density (relative to water) of 1.73. Measurements were also made using films for 15- and 9-Mev electrons in a phantom with a mandibular bone and teeth. A dose enhancement in bone of approximately 10% and 7%, respectively, for the two energies was found in the phantom where the electron density of bone was about 1.60. These results suggest that injury to bone is possible in those clinical situations where high doses of electrons are used for therapy.
This study investigated dose to bone tissue in electron beam therapy. Measurements were made using films and thermoluminescent dosimeters in a polystyrene phantom containing bone inhomogeneity for 15-MeV, 12-MeV, and 9-MeV electron beams. An increase in dose of approximately 18%, 12%, and 11%, for the three electron energies respectively, relative to the dose in polystyrene, was found for bone material having an electron density (relative to water) of 1.73. Measurements were also made using films for 15- and 9-Mev electrons in a phantom with a mandibular bone and teeth. A dose enhancement in bone of approximately 10% and 7%, respectively, for the two energies was found in the phantom where the electron density of bone was about 1.60. These results suggest that injury to bone is possible in those clinical situations where high doses of electrons are used for therapy.
The Monte Carlo method is used to analyse the dose fall-off at the exit surface of a megavoltage photon beam. The convolution/superposition method of dose calculation using Monte-Carlo-generated homogeneous photon kernels is shown to be in error for exit dose calculation. Instead, photon kernels that incorporate modelling of the exit surface were generated, also using Monte Carlo, to analyse the problem, and the calculated dose fall-off using these kernels agrees well with measured data. In addition, the physics underlying the characteristics of the dose fall-off is analysed based on complete Monte Carlo modelling. Practical improvements to the convolution/superposition method are suggested. (Author).
The interaction of cis-diamminediaquoplatinum(II) nitrate with adenosylcobalamin and a series of alkylcobalamins was studied by carbon-13 nuclear magnetic resonance spectroscopy and by electronic spectroscopy. With these cobalamins cis-(Pt(NH/sub 3/)/sub 2/(OH/sub 2/)/sub 2/)/sup 2 +/ forms adducts in which N(3) of the 5,6-methylbenzimidazole moiety is co-ordinated to platinum(II) rather than to cobalt(III) of the corrin. The chemical shifts of the 5'-methylene carbon of adenosylcobalamin-platinum adduct and of the Co-methyl carbon of the methylcobalamin-platinum adduct are characteristic of these cobalamins in the base-off form. Furthermore, these cobalamin-platinum complexes have visible spectra identical to those of the cobalamins in acidic solution. The /sup 13/C NMR spectrum of the adenosylcobalamin-platinum complex suggests the presence of a second adduct in which platinum(II) complexes are co-ordinated to ...
Porous phosphate heterostructures (PPH), functionalized with different ratios of aminopropyl and mercaptopropyl groups, labelled as Nx=5,25,50-PPH and Sx=5,25,50-PPH, respectively, were tested as adsorbents for Ni(II) and Hg(II) found in industrial sewage from electroplating processes and button battery recycling. X-ray diffraction was used to study the structures. The specific surface area of the pristine material (PPH) was 620m^2g^-^1, whereas the specific surface areas of the modified mercaptopropyl (S5-PPH) and aminopropyl (N5-PPH) were 472 and 223m^2g^-^1, respectively. The adsorption data were fitted to a Langmuir isotherm model. The S5-PPH material was saturated by 120mmol Hg(II) per 100g of material, whereas for Ni(II) adsorption, N25-PPH material displayed the highest adsorption w...
The relationship between serum PG I, PG II levels and extent of atrophic gastritis was examined. The subjects were 64 patients (male: 32, female: 32, 51.9 years old on average) with established diagnosis of either atrophic gastritis or normal. In the X-ray gastric examination, Fuji Computed Radiography (FCR) was used to obtain clear-cut images of the gastric area. Concerning the serum PG I level, patients in the group with atrophic gastritis showed lower levels than those of the people in the group with no atrophic change, but the variation was wide, and no definite tendency was seen in the relationship between the atrophic change and the serum PG I levels. Concerning the serum PG II level, as the atrophic change progresses, the serum PG II level tended to increase gradually. A significant reduction in the PG I/II ratio was seen in the group with atrophic changes (p<0.01) in comparison with the group ...
The relationship between serum PG I, PG II levels and extent of atrophic gastritis was examined. The subjects were 64 patients (male: 32, female: 32, 51.9 years old on average) with established diagnosis of either atrophic gastritis or normal. In the X-ray gastric examination, Fuji Computed Radiography (FCR) was used to obtain clear-cut images of the gastric area. Concerning the serum PG I level, patients in the group with atrophic gastritis showed lower levels than those of the people in the group with no atrophic change, but the variation was wide, and no definite tendency was seen in the relationship between the atrophic change and the serum PG I levels. Concerning the serum PG II level, as the atrophic change progresses, the serum PG II level tended to increase gradually. A significant reduction in the PG I/II ratio was seen in the group with atrophic changes (p<0.01) in comparison with the group ...
The biosorption characteristics of Cd(II) ions using the red alga (Ceramium virgatum) were investigated. Experimental parameters affecting the biosorption process such as pH, contact time, biomass dosage and temperature were studied. Langmuir, Freundlich and Dubinin-Radushkevich (D-R) models were applied to describe the biosorption isotherms. The biosorption capacity of C. virgatum biomass for Cd(II) ions was found to be 39.7 mg/g. From the D-R isotherm model, the mean free energy was calculated as 12.7 kJ/mol, indicating that the biosorption of Cd(II) the metal ions was taken place by chemisorption. The calculated thermodynamic parameters ({delta}G{sup o}, {delta}H{sup o} and {delta}S{sup o}) showed that the biosorption of Cd(II) ions onto C. virgatum was feasible, spontaneous and exothermic at 293-323 K. Evaluation of experimental data in terms of biosorption kinetics showed that the biosorption of ...
Apparent molar volumes V{sub phi} and apparent molar heat capacities C{sub p,phi} were determined for aqueous solutions of nickel(II) nitrate, copper(II) nitrate, and zinc(II) nitrate at molalities m=(0.01 to 0.5) mol {center_dot} kg{sup -1}, and at the pressure p=0.35 MPa. Solution densities obtained using a vibrating-tube densimeter at T=(278.15 to 368.15) K were used to calculate V{sub phi} values. Heat capacity measurements obtained with a twin fixed-cell, differential-output, power-compensating, temperature-scanning calorimeter at T=(278.15 to 393.15) K were used to calculate values of C{sub p,phi}. Our results were then fitted to functions of m and T and compared to literature values.
The chemical operational concept originally established for the water-steam circuit of Angra II nuclear power plant has undergone several modifications throughout the development of the project. This work discusses the two main modifications giving special attention to the costs involved and analyses the main points and the consequences of such modifications 1 ref., 4 figs., 2 tabs.
System-level-operational testing of the ETX-II test-bed electric vehicle is described and the results discussed. Because the traction battery is a major factor in the performance of an electric vehicle, previously reported work on the sodium-sulfur battery designed for use with the ETX-II is reviewed in detail. Chassis dynamometer performance of the test-bed vehicle met or exceeded design goals and compared reasonably well with SIMPLEV computer modeling results. Areas are identified wherein further work is needed to establish a firmer basis for comparison of the simulation and the observed results.
A lot of effort has been made to spread the application of RTOS in embedded system development in China. RTOS, #mu#C/OS and #mu#C/OS-II, with its opened source code, is well known in embedded systems. Learning RTOS, Using RTOS, becomes more and more popular. The Book of 'Micro C/OS-II The Real-Time Kennel Second Edition' was published in 2002. Here some new progress of the RTOS, especially the safety certifications, the reliability of software is introduced. (authors)
To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca{sub 2}SO{sub 4}:Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let ...
International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the absorbed ...
The KENTORT II process includes integral fluidized bed zones for pyrolysis, gasification, and combustion of the oil shale. The purpose of this program is to design and test the KENTORT II process at the 50-lb/hr scale. Along with the major activity of assembling the components of the 50-lb/hr retort, work was also completed in other areas this quarter. Basic studies of the cracking and coking kinetics of model compounds in a fixed bed reactor were continued. Additionally, as part of the effort to investigate niche market applications for KENTORT II-derived products, a study of the synthesis of carbon fibers from the heavy fraction of KENTORT II shale oil was initiated.
Active Activator (Ac) elements undergo mutations to become nonautonomous Dissociation (Ds) elements at a low frequency. To understand...Full Text Available
... in Taylor and Williamson.* Most satellite sensors cannot be ... The coordinates of the rocket Ii ... I - Incoming Global Radiant Flux between 0.285 and ...
Abstract Copper(II) bis(thiosemicarbazone) are very useful for blood flow and hypoxic imaging. The aim of this study was to identify structure-activity relationships (SARs) within a series of analogues with different substitution patterns in the ligands, in order to design improved hypoxia imaging agents and elucidate hypoxia selectivity mechanisms. Genetic algorithms (GAs) were used to develop specific copper metal-ligand force field parameters for the MM3 force-field calculations. These new parameters produced results in good agreement with experiment and previously reported copper metal-ligand parameters. A successful quantitative SAR (QSAR) for predicting the several classes of Cu(II)-chelating ligands was built using a training set of 21 Cu(II) complexes. The QSAR exhibited a correlat...
missionaries and cannibals puzzle. He noted that in order to be able to use a boat to cross a river one would need ... a quali cation that the vertical exhaust stack ...
... And those who study cognition select problems (eg, tower of Hanoi, missionaries and cannibals, logic theorems) with minimal perceptual and motor ...
Form as the end result of massive star evolution; Type II supernova: collapse of iron core in highly evolved massive star; outer regions blasted away in ...
... centers in materials research. MRSECs address fundamental materials research topics of intellectual ... in materials research. II. PROGRAM DESCRIPTION MRSECs are supported by NSF to undertake materials ...
The biosorption of lead, copper and zinc ions on Rhizopus arrhizus has been studied for three single-component and two binary systems. The equilibrium data have been analysed using the Freundlich adsorption model. The characteristic parameters for the Freundlich adsorption model have been determined and the competition coefficients for the competitive biosorption of Pb(II)-Cu(II) at pH 4.0 and 5.0, and Pb(II)-Zn(II) at pH 5.0 have been calcualted. For the individual single-component isotherms, lead has the highest biosorption capacity followed by copper, then zinc. The capacity of lead in the two binary systems is always significantly greater than those of the other metal ions, in agreement with the single-component data. Only a partial selectivity for copper ions has been obtained at pH 4.0. (orig.)
Hexavalent chromium in corrosion preventive coating 64 ...To prevent corrosion of rims, weights can be provided with a coating. ...integrated clips brought up technical problems due to corrosion
... Science, Computer Vision, Digital Government, Digital Libraries, Digital Society and Technologies ... for Robust Intelligence, Digital Government, and Digital Libraries and Archives. In subsequent years ...
... Ready-to-Eat (MRE) VIII operational ration was evaluated at a field training exercise (Market Square II) with troops of the 82nd Airborne Division. ...
Given a double complex $X$ there are spectral sequences with the $E_2$ terms being either H$_I$ (H$_{II}(X))$ or H$_{II}($H$_I (X))$. But if $H_I(X)=H_{II}(X)=0$ both spectral sequences have all their terms 0. This can happen even though there is nonzero (co)homology of interest associated with $X$. This is frequently the case when dealing with Tate (co)homology. So in this situation the spectral sequences may not give any information about the (co)homology of interest. In this article we give a different way of constructing homology groups of $X$ when H$_I(X)=$H$_{II}(X)=0$. With this result we give a new and elementary proof of balance of Tate homology and cohomology.
For intensity modulated radiation treatment (IMRT) dose reconstruction, multileaf collimator (MLC) log files have been shown applicable for deriving delivered fluence maps. However, MLC log files are...Full Text Available
1. The antihypertensive efficacy and tolerability of a low dose combination of the angiotensin converting enzyme inhibitor ramipril (2.5 mg) and the extended release formulation of the dihydropyridine...Full Text Available
We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator ...
Estimations on the somatic and genetic effects of small doses of ionizing radiations in Man have been proposed by the Advisory Committee on the Biological Effects of Ionizing Radiation, set up by the U.S. National Academy of Sciences. They have been published in an important report, issued in 1972, from which we briefly analyze here the Chapter dealing with the somatic effects. Small doses of raditions are expected to promote only carcinogenic effects. After a rapid survey of the human experience on which the estimations are based, as regards the latent period of cancers, the plateau region (period of high risk) and the absolute and relative risk expressed per rem, per 10"6 persons, per year, for leukaemia (having the highest risk) and for the ''other cancers''. These estimations were obtained by linear extrapolation to the 1 rem level from observations made after irradiation at relatively high dose levels and much higher ...
The pharmacokinetics of ceftriaxone were investigated in six healthy mainland Chinese adults (four males and two females). A single 1.0-g dose was administered intravenously or intramuscularly in a...Full Text Available
Objectives To provide direct estimates of risk of cancer after protracted low doses of ionising radiation and to strengthen the scientific basis of radiation protection standards for environmental,...Full Text Available
AimsTo assess the tolerability and pharmacokinetic profile of single and repeat doses of the oral matrix metalloproteinase inhibitor marimastat in healthy male volunteers.Full Text Available
Calculations of dose per monitor unit (D∕MU) are required in addition to measurements to increase patient safety in the clinical practice of proton radiotherapy. As in conventional photon and...Full Text Available
The achievements made in the field of radiation protection over the past 20 years are outlined. Risk analysis as applied to medicine is considered and genetic significant doses, genetic risks, somatic effective doses and somatic risks are discussed. (C.F.).
Low dose methotrexate has been used effectively for various rheumatic and non-rheumatic diseases. Three cases of Pneumocystis carinii pneumonia occurring during treatment of rheumatoid arthritis with...Full Text Available
BackgroundThe aim of this study was to compare and to validate different dose calculation algorithms for the use in radiation therapy of small lung lesions and to optimize the treatment...Full Text Available
The reference medium for brachytherapy dose measurements is water. Accuracy of dose measurements of brachytherapy sources is critically dependent on precise measurement of the source–detector...Full Text Available
AbstractMilk residues and performance were evaluated in lactating cows that were fed up to 10 times the recommended dose of monensin. Following an acclimatization period of 14 d, during...Full Text Available
The purpose of this report is to summarize the assumptions, dose factors, consumption rates, and methodology used to evaluate potential radiation doses to persons who may eat contaminated wildlife or contaminated plants collected from the Hanford Site. This report includes a description of the number and variety of wildlife and edible plants on the Hanford Site, methods for estimation of the quantities of these items consumed and conversion of intake of radionuclides to radiation doses, and example calculations of radiation doses from consumption of plants and wildlife. Edible plants on the publicly accessible margins of the shoreline of the Hanford Site and Wildlife that move offsite are potential sources of contaminated food for the general public. Calculations of potential radiation doses from consumption of agricultural plants and farm animal products are made routinely and ...
For the risk estimate of fatal malignancies, an effective dose was proposed on the basis of the assumption that the risk should be equal whether the whole body irradiated uniformly or whether there is non-uniform irradiation. The effective dose was defined by the product of organ or tissue doses and a weighting factor representing the proportion of risk factor for a fatal malignancy resulting from organ or tissue irradiation to the total malignant factor. The risk of malignancies can be derived by multiplying the malignant significant factor by the product of the risk factor and the effective dose. For the genetic risk, a significant factor was a relative child expectancy and organ or tissue doses were gonad doses. And, for the leukemogenic risk, a significant factor was the leukemia significant factor and organ or tissue dose was mean bone ...
1. The LD50 of iodomethane orally administered to rats is 76mg./kg. body wt. but repeated daily doses of 30–50mg./kg. body wt. are without effect. 2. Oral doses of iodomethane to...Full Text Available
A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL sheet was suggested to provide a convenient ...
Objective:In this article, we describe a successful low-dose, off-label usage of drotrecogin alfa (Xigris), given at 18 mcg/kg per hour, in a patient with severe sepsis who had an...Full Text Available
ObjectiveTo assess the efficacy and safety of low dose adrenaline injected subcutaneously to prevent acute adverse reactions to polyspecific antivenom serum in patients admitted...Full Text Available
Rats were exposed to aerosols of "2"3"3U and "2"3"2U nitrate in a study of the long-term biological effects. Preliminary radiation dose estimates show lung > skeleton > kidney in each dose group.
The equivalent doses of K-feldspar grains in a range of grain sizes from 90 to 250#mu#m diameter were measured using a single-aliquot regenerative-dose protocol for the infrared stimulated luminescence (IRSL) signals for two samples of desert sand. The equivalent doses for each sample were compared with that for the 125-150#mu#m grains of quartz from the same samples. The results suggested that the K-feldspar equivalent doses were underestimated because of anomalous fading. Measurements of the decay of the IRSL signals following laboratory irradiation for these two samples, and an additional one from a previously published isochron study, showed anomalous fading during the period of laboratory storage. The decay rate was about 3% per decade for all samples and was independent of the grain size used. Using plots of equivalent doses for K-feldspars as a function of their calculated ...
1. The effect of three single doses of nifedipine on exercise-induced asthma has been examined in 11 asthmatic subjects. 2. On four separate days patients undertook 6 min of exercise on a treadmill...Full Text Available
Somatic radiation doses are recognized to be possible factors of carcinogenesis. In correctly performed mammography, however, even as screening test, the radiation dose does not reach such an order of magnitude that the benefit of the procedure as to prevention of breast cancer is called into question.
IMRT optimization requires a fast yet relatively accurate algorithm to calculate the iteration dose with small memory demand. In this paper, we present a dose calculation algorithm that approaches these goals. By decomposing the infinitesimal pencil beam (IPB) kernel into the central axis (CAX) component and lateral spread function (LSF) and taking the beam's eye view (BEV), we established a non-voxel and non-beamlet-based dose calculation formula. Both LSF and CAX are determined by a commissioning procedure using the collapsed-cone convolution/superposition (CCCS) method as the standard dose engine. The proposed dose calculation involves a 2D convolution of a fluence map with LSF followed by ray tracing based on the CAX lookup table with radiological distance and divergence correction, resulting in complexity of O(N"3) both spatially and temporally. This simple algorithm is orders ...
Based on the replies to a questionnaire distributed throughout Japan in 1983, genetically significant dose (GSD), per Caput mean bone marrow dose (CMD), leukemogenically significant dose (LSD), malignantly significant dose (MSD), and per Caput effective dose equivalent (EDE) from using small sealed radiation sources for radiotherapy were estimated. Annual frequencies of brachytherapy were estimated to be 2.6 x 10"3 for men and 36.3 x 10"3 for women, with a total of 38.9 x 10"3. The annual frequencies of using afterloading technique were 0.3 x 10"3 for men and 18.8 x 10"3 for women, with a total of 19.1 x 10"3. The annual population doses per person were 7.9 nGy for GSD, 118 #mu#Gy for CMD, 19.3 #mu#Gy for LSD, 172 #mu#Gy for MSD, and 428 #mu#Gy for EDE. The annual collective effective dose equivalent was estimated to be 5.13 x 10"4 man Sv. ...
This volume presents the collations tables of a six volume comparative epidemiological survey of the effects of low level radiation dose. Data are collated for the effects observed in the following irradiated groups:- Preconception irradiation, intra-uterine irradiation, childhood irradiation, adult irradiation. (UK).
The genetically significant dose (GSD) is an index variable which exclusively allows to describe the genetic risk in the progeny of a population due to the application of ionizing radiation and radioactive substances in one part of this population. It may result in wrong interpretation of population exposure at increasing incidence of examinations in a population involving ionizing radiation and radioactive drugs at simultaneously increasing application of alternative methods in children and adolescents owing to the fact that it indicates a downward trend although somatic exposure of this population has increased. Therefore, it is recommended to state both the GSD and the level of somatic radiation exposure of the population taken from the individual sources for the comparison and assessment of radiation exposure from various sources in future. Although the somatically significant dose constitutes the suitable variable complementary to GSD in ...
Ionising radiation induces stable free radicals in chicken bones and in the shell of chicken eggs which can be detected, by the electrons spin resonance (ESR) technique, well beyond the shelf-life of the food and can be used for dosimetry. The method usually adopted to evaluate ``a posteriori`` the dose given during the ionising radiation treatment of food, is the dose additive method. To assess the dose, the ESR signal amplitude of the irradiated food (bone or egg shell in the present case) is measured and then the dose-effect relationship is obtained by re-irradiating the sample with some additive doses (usually of 1 kGy). The dose-effect curve is back-extrapolated and the initial given dose determined. At the Istituto Superiore di Sanita (ISS), Rome, Italy, a research programme was approved two years ago aimed to, (1) study new ...
PurposeTo investigate the influence of inhomogeneity corrections on stereotactic treatment plans for non-small cell lung cancer and determine the dose delivered to the PTV and OARs.Full Text Available
IntroductionThe optimal dialysis dose for the treatment of acute kidney injury (AKI) is controversial. We sought to evaluate the relationship between renal replacement therapy (RRT)...Full Text Available
While there have been many experimental and calculational investigations on absorbed dose distribution in the patient resulting from conventional X-ray procedures, such data for computerized tomography (CT) are still sparse. As this diagnostic procedure has shown a rapid increase in application during recent years, we have determined absorbed dose to body organs in a human phantom resulting from CT examinations. The exposure model consists of the heterogeneous MIRD-5 phantom and a suitable Monte-Carlo method to calculate absorbed dose to organs of interest. The exposure conditions are specified according to the exposure specifications of a CT-scanner currently in use. The calculations cover the range of body tissues of interest in terms of organ absorbed doses as well as a risk weighted absorbed dose. A detailed example showing the calculation of red bone marrow ...
An earlier representation of the radial distribution of dose about the path of a heavy ion in liquid water is modified and extended to include silicon, lithium fluoride, and sodium iodide. 6 refs., 5 figs., 1 tab.
Techniques for reducing computation time in 3D photon dose calculations are addressed with specific emphasis given to the convolution/superposition approach. A single polyenergetic superposition model calculating absorbed dose per incident photon fluence (Gy cm"2) was developed in terms of TERMA and a total energy deposition kernel (a total point spread function). A novel approach was devised for reducing calculation time. The method, named the CF method, was based on the use of a conventional, fast model (here a modified power-law method was used) for the generation of 3D dose distributions on a fine dose matrix. Superposition calculations were carried out on a coarse matrix and calculation speed was increased simply by reducing the number of calculations. A set of correction factors was derived on the coarse grid from the ratio of the dose values from superposition to those from ...
Background/AimTobacco use reduces the effect of non-surgical periodontal therapy. Host-modulation with low-dose doxycycline (LDD) might favour repair and promote...Full Text Available
Survival curves were constructed from dose-incidence curves for apoptosis in the crypts of mouse small intestine, using the number of apoptotic cells after high doses (N{sub M}) as maximum cell population size. The mean lethal doses (D{sub 0}) for the dose range 0-0.5 Gy were calculated for each time of day. A circadian rhythm in both D{sub 0} and N{sub M} values was detected, indicating that both the number and sensitivity of radiation-induced apoptosis were changing throughout the day. (author).
Mixed Uranium Plutonium Carbide ((U, Pu) C), in the form of pellets encapsulated in stainless steel tubes is the fuel for Fast Breeder Test Reactor (FBTR) at Kalpakkam. For the fabrication of fuel for enlarging the core of this reactor, high burn up plutonium is used. The external exposure in these labs was significantly higher than that with low burn up Pu fuel. Dose evaluation to the organs was carried out using experimental TLDs during various operations of FBTR fuel fabrication to study the dose distribution pattern. (author)
The authors give a survey of the somatic radiation risk in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk.
The authors give a survey of the somatic radiation ris in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk. (orig.).
Health physicists from the Brookhaven National Laboratory (BNL) visited the Savannah River Site (SRS) as one of 12 facilities operated by the Department of Energy (DOE) contractors with annual collective dose equivalents greater than 100 person-rem (100 person-cSv). Their charter was to review, evaluate and summarize as low as reasonably achievable (ALARA) techniques, methods and practices as implemented. This presentation gives an overview of the two selected ALARA practices implemented at the SRS: Administrative Exposure Limits and Goal Setting. These dose control methods are used to assure that individual and collective occupational doses are ALARA and within regulatory limits.
Health physicists from the Brookhaven National Laboratory (BNL) visited the Savannah River Site (SRS) as one of 12 facilities operated by the Department of Energy (DOE) contractors with annual collective dose equivalents greater than 100 person-rem (100 person-cSv). Their charter was to review, evaluate and summarize as low as reasonably achievable (ALARA) techniques, methods and practices as implemented. This presentation gives an overview of the two selected ALARA practices implemented at the SRS: Administrative Exposure Limits and Goal Setting. These dose control methods are used to assure that individual and collective occupational doses are ALARA and within regulatory limits.
For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)
An important unresolved issue in outcomes analysis for lung complications is the effect of poor or completely lacking heterogeneity corrections in previously archived treatment plans. To estimate this effect, we developed a novel method based on Monte Carlo (MC) dose calculations which can be applied retrospectively to RTOG/AAPM-style archived treatment plans (ATP). We applied this method to 218 archived nonsmall cell lung cancer lung treatment plans that were originally calculated either without heterogeneity corrections or with primitive corrections. To retrospectively specify beam weights and wedges, beams were broken into Monte Carlo-generated beamlets, simulated using the VMC++ code, and mathematical optimization was used to match the archived water-based dose distributions. The derived beam weights (and any wedge effects) were then applied to Monte Carlo beamlets regenerated based on the patient computed tomography densities. Validation ...
The paper presents information in the form of data, tables and diagrams compiled to a broad but very up-to-date survey of required radiation for the various most frequently performed X-ray examinations of patients. The required dose is discussed from the point of view of radiation protection, defining the inevitably administered dose to the skin, the frequency of examinations, and the diagnostic image quality as the main three factors to be observed, as these determine the radiation dose to the patient and to the personnel. The somatic risks of radiography examinations are a point of main interest. (DG).
Contributions to the population dose due to medical applications of ionising radiation are presented. It appears that contributions due to radiotherapy and X ray diagnosis are of comparable magnitude. To account for the age dependency of the radiation risks, contributions in terms of somatically significant dose equivalent are calculated as 0.3 mSv per caput per annum for X ray diagnosis and as 0.2 mSv per caput per annum for radiotherapy, the latter referring to only doses to organs outside the target volume. (author).
Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).
Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).
In radiation risk assessment it must be differentiated between somatic and genetic effect on the one hand as well as between stochastic and non-stochastic effect on the other. According to definitions of the ICRP report 26 the limit for the dose equivalent of all tissues prevents non-stochastic radiation effects. With stochastic radiation effects probably exist no threshold doses; therefore the ALARA principle must be applied concerning radiation protection. The individual risk by stochastic radiation effects in its linear, linear-quadratic and quadratic extrapolations, respectively, is discussed in detail. The effective stochastic dose equivalent (H/sub eff/) as well as collective dose and collective damage are outlined.
Background and purpose: The low density of lung tissue causes a reduced attenuation of photons and an increased range of secondary electrons, which is inaccurately predicted by the algorithms incorporated in some commonly available treatment planning systems (TPSs). This study evaluates the differences in dose in normal lung tissue computed using a simple and a more correct algorithm. We also studied the consequences of these differences on the dose-effect relations for radiation-induced lung injury. Materials and methods: The treatment plans of 68 lung cancer patients initially produced in a TPS using a calculation model that incorporates the equivalent-pathlength (EPL) inhomogeneity-correction algorithm, were recalculated in a TPS with the convolution-superposition (CS) algorithm. The higher accuracy of the CS algorithm is well-established. Dose distributions in lung were compared using isodoses, ...
Purpose Study the radiolysis of solid-state metoclopramide hydrochloride at various absorbed doses. Elucidate the structure of the degradation products to gain information on the radiolysis mechanisms. Methods Solid-state metoclopramide samples were irradiated at several doses with gamma rays and high-energy electrons to evaluate the influence of the dose rate. High-performance liquid chromatography with a diode array detector was used to measure the chemical potency as a function of the absorbed dose and to quantify the degradation products. The characterization of degradation products was performed by liquid chromatography/atmospheric pressure chemical ionization/tandem mass spectrometry. Results The degradation of solid-state metoclopramide after irradiation was negligible. No qualitati...
During one year more than 40,000 items of information on radiation exposure of personnel involved in the handling of radiation sources and more than 5,000,000 items on irradiation of other people are collected in the authors' laboratory. Considerable progress in assessment of mean annual gonad dose of genetically sifnificant dose was attained by means of an algorithm for a personal computer. This simple and inexpensive system has led to a higher accuracy in the application of protective measures. (author).
A compartment model is described which is currently used by the Ministry of Agriculture, Fisheries and Food to calculate collective radiation exposure due to liquid radioactive wastes discharged to sea from UK nuclear sites. Collective dose is a useful indicator of the radiological impact of a disposal practice and is one of the quantities needed to show compliance with the ICRP system of dose limitation. The model has been used for the purposes of the Sizewell Inquiry to predict the collective radiation exposure from reactor operation at Sizewell and, on the basis of current Sellafield experience, correlations between dose and discharge for disposals of fuel reprocessing wastes. (author).
The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.
This report revises estimates of population exposure to external natural background made by D. T. Oakley in 1972. The revisions include more recent estimates of dose equivalents from cosmic rays, use of 1970 U.S. census data, and corrections for building shielding and for self-shielding in the body. The dose equivalents calculated are those from cosmic rays and terrestrial radiation, and do not include doses from natural radioactive materials in the body.
As a series of estimations of population doses and of risk estimates from medical exposures in Japan, the malignancy significant dose (MSD) and the fatal malignant risk from beam therapy were estimated based on a nationwide survey of radiotherapeutic treatments, using a malignancy significant factor and a weighting factor determined from the data on the cancer mortality among the atomic bomb survivors in Nagasaki. The effective dose was defined as a sum of the product of the weighting factor and the organ or tissue doses with respect to the malignant diseases. The organ or tissue doses were determined with ionization chambers placed at the positions of their center in a MixDp-phantom simulated lung tissues by a block of cork, using a telecobalt unit, a conventional X-ray unit and a medical linear accelerator. The organ or tissue doses were categorized into three ...
With accurate calculation algorithms in inverse planning for beamlet-based intensity modulated radiotherapy (IMRT), it takes time to calculate the dose matrix, which represents the dose distribution of each beamlet element to each voxel for unit fluence. To reduce the calculation time, coarse or approximate algorithms are often a choice, but this results in a final dose distribution that cannot reflect the real value. In addition, it is necessary to test if a coarse algorithm is capable of calculating the dose matrix of beamlets. In this work, simulated dynamics optimization algorithm was applied to optimize the segment weight to minish the dose error from the dose matrix calculation. After calculating the dose matrix by ray-tracing algorithm which takes into account just the primary component of absorbed dose, the ...
This paper introduces an occupational exposure information system in detail, which is developed and in operation presently by Daya Bay nuclear power plant. It is presented in the paper that individual dose monitoring items and method, design and classification of database configuration, statistics and analysis of individual dose, and management of staff entering and exiting controlled area. The system is instructive to analysing individual dose and optimizing radiation protection measures. (authors)
Analytical expressions for thermoluminescence (TL) dating based on the modified Zimmerman model were derived. The non-linear behaviour of TL sensitivity is reexamined and is found to be due to electron capturing competitions in both test-dose excitation and the readout stages. A curve fitting method is proposed to determine the paleodose for the additive dose dating method. The multiple activation technique is also investigated, from which the paleodose should be regarded as an upper limit.
Analytical expressions for thermoluminescence (TL) dating based on the modified Zimmerman model were derived. The non-linear behaviour of TL sensitivity is reexamined and is found to be due to electron capturing competitions in both test-dose excitation and the readout stages. A curve fitting method is proposed to determine the paleodose for the additive dose dating method. The multiple activation technique is also investigated, from which the paleodose should be regarded as an upper limit.
Epidemiological studies will not solve the shape of the dose effect curve for stochastic effects in the low dose range. Unicellular processes are necessary for the primary processes so that no threshold dose exists. This is evident for somatic and genetic mutations. Not clearly solved is this question for the complex carcinogenesis. These processes develop with manifold interacting molecular and cellular steps. (orig.).
Biomedical science researchers often express frustration that health physics practices vary widely between individual institutions. A survey examining both internal and external dose assessment practices was devised and mailed to fifty institutions supporting biomedical science research. The results indicate that health physics dose assessment practices and policies are highly variable. Factors which may contribute to the degree of variation are discussed. 2 tabs.
The population doses and risks of stochastic effects from occupational exposures in Japan in 1978 were estimated on the basis of a nation-wide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 82,500 workers other than the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the offitial publication of the Japan Nuclear Safety Commission. The total number of workers except for nuclear power stations was estimated to be about 170,000 persons. Radiation works were subdivided as follows: medical works including dental; nondestructive inspectional; non-atomic energy industrial; research and educational; atomic energy industrial and nuclear power industrial. The annual collective dose equivalents were estimated to be about 6,000 man rem for medical workers, 450 man rem for non-destructive inspectional, ...
This article introduces the composition, monitoring methods and working principles of environmental #gamma# dose rate continuous monitoring system at Guangdong Daya Bay Nuclear Power Station. The #gamma# dose rate monitoring status after modification of measurement conditions is introduced too.
The study compares the doses absorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations.
The objectives of this project to interface the site-specific real-time radiological dose assessment system FADAS(Following Accident Dose Assessment System) to CARE. In this study, the results of the field tracer experiments conducted on the Younggwang site have been analysed. And the experimental procedure on Ulchin site has been introduced. The environmental characteristics on Ulchin and Wolsung has been investigated.
BackgroundSeveral studies have demonstrated the efficacy of artemisinin-combination therapy (ACT) across malaria zones of the world. Fixed dose ACT with shorter courses and fewer...Full Text Available
The purpose of this study is to evaluate the accuracy of dose calculations by three algorithms. Depth dose, OPF (Output Factor) and dose profiles were measured in a heterogeneous phantom. These values were also calculated by three algorithms of the Batho power law (BPL), Equivalent-Tissue Air Ratio (ETAR) and Convolution superposition (CS). The data were obtained for 4, 6 and 10 MV photon beams with a linear accelerator (Varian 21EX). Field size ranged from 3 x 3 cm"2 to 10 x 10 cm"2. Dose profiles of beam penumbra were also measured by a 0.125 ml ionization chamber at the point of 8, 13 and 18 cm from the surface of the phantom at intervals of 1 mm. Differences between measured and calculated depth doses were within 2% in BPL and CS, but depth doses were overestimated in ETAR. OPFs were also overestimated with the error of more than 4% in ETAR. Absorbed ...
The implementation of the convolution/superposition method in real dose planning situations is considered. The modelling of photon spectra, the use of patient and treatment setup information, and the calculation of the photon energy released in a patient are detailed. A comparison is made between the approaches of calculating the relative dose directly and using a factor derived from measurements to correct the calculated relative dose. 13 refs.; 7 figs.
Full text: Verification of the dose delivered to a patient during radiotherapy is an important quality assurance procedure, however this is rarely performed due to the extra time involved. Electronic portal images (EPIs) are currently acquired at many centres during radiotherapy treatment for positioning verification. These could be utilised for dose verification provided 1) an accurate prediction of the dose transmitted through the patient to the EPID can be produced for the patients' radiotherapy beams, and, 2) the EPID image can be converted to an accurate measured dose. Ideally, the radiotherapy planning system (RTPS) would be used to produce the predicted dose as part of the planning procedure. The aim of this project is to investigate whether the convolution-superposition model of the Pinnacle RTPS can accurately calculate dose transmitted through a ...
Convolution/superposition (C/S) is regarded as the standard dose calculation method in most modern radiotherapy treatment planning systems. Different implementations of C/S could result in significantly different dose distributions. This paper addresses two major implementation issues associated with collapsed cone C/S: one is how to utilize the tabulated kernels instead of analytical parametrizations and the other is how to deal with voxel size effects. Three methods that utilize the tabulated kernels are presented in this paper. These methods differ in the effective kernels used: the differential kernel (DK), the cumulative kernel (CK) or the cumulative-cumulative kernel (CCK). They result in slightly different computation times but significantly different voxel size effects. Both simulated and real multi-resolution dose calculations are presented. For simulation tests, we use arbitrary kernels and various voxel sizes ...
In order to study the intragenic profiles of active transcription, we determined the relative levels of active RNA polymerase II present at the 3′- and 5′-ends of 261 yeast genes by...Full Text Available
The temporal patterns of protein phosphorylation in the adrenal glomerulosa cell were analysed by two-dimensional electrophoresis after stimulation with 10 nM-angiotensin II or various agents [10 nM-12-O-tetradecanoylphorbol...Full Text Available
Silanization of the silica gel surface in the synthesis of silica gel polyamine composites uses (chloropropyl)-trichlorosilane (CPTCS). It is possible to substitute a molar fraction of reagent CPTCS with methyltrichlorosilane (MTCS), creating a mixed silane surface layer. Two types of silica gels were modified with a series of MTCS:CPTCS molar ratios. Solid-state CP/MAS 29Si and 13C NMR spectroscopies were used to evaluate the surface silane composition. Surface silane coverage was markedly improved for the resulting gels. When polyamines were grafted to the resultant MTCS:CPTCS silane layers, it was shown that the decrease in the number of propyl attachments to the polyamine resulted in increased quantities of ''free amines''. Optimum MTCS:CPTCS ratios were determined for three polyamines grafted onto one silica gel. A substantial free amine increase was observed for poly(allylamine) (PAA). Metal uptake studies show increases in ...
Silanization of the silica gel surface in the synthesis of silica gel polyamine composites uses (chloropropyl)-trichlorosilane (CPTCS). It is possible to substitute a molar fraction of reagent CPTCS with methyltrichlorosilane (MTCS), creating a mixed silane surface layer. Two types of silica gels were modified with a series of MTCS:CPTCS molar ratios. Solid-state CP/MAS 29Si and 13C NMR spectroscopies were used to evaluate the surface silane composition. Surface silane coverage was markedly improved for the resulting gels. When polyamines were grafted to the resultant MTCS:CPTCS silane layers, it was shown that the decrease in the number of propyl attachments to the polyamine resulted in increased quantities of ''free amines''. Optimum MTCS:CPTCS ratios were determined for three polyamines grafted onto one silica gel. A substantial free amine increase was observed for poly(allylamine) (PAA). Metal uptake studies show increases in ...
The spin-up problem of He II in a cylindrical container of infinite and finite height is considered on the basis of the Hall-Vinen-Bekarevich-Khalatnikov equations. The boundary conditions include the assumption of the generation of superfluid vorticity at the walls of the container. In the lowest order approximation with respect to viscosity, the problem is reduced to a Stefan problem for a single diffusion-type equation. Examples of solutions are given which show that the method used gives a good insight into the physical development of the spin-up flow.
Type II NAD(P)H:quinone oxidoreductases (NDH-2) catalyze the two-electron transfer from NAD(P)H to quinones, without any energy-transducing site. NDH-2 accomplish the turnover of NAD(P)H, regenerating...Full Text Available
It is shown that observations of the lithium isotope ratio in high surface temperature Population II stars may be critical to cosmological nucleosynthesis models. In particular, decaying particle scenarios as derived in some supersymmetric models may stand or fall with such observations. 18 references.
These three volumes cover liposome technology in pharmacology and medicine. Contributors emphasize methodology used in their own laboratories, and include a brief introduction, coverage of relevant literature, applications and critical evaluations for the methods they describe. Volume II presents procedures for the entrapment of a number of drugs, including genetic material, into selected types of liposomes.
The theoretical evolution of a horizontal branch star of Population II is followed through the helium burning in the core phase and is compared with the results given by other investigators. The m- fluence of different physics and interpolation schemes in the opacity tables is discussed. Some thoughts are given on the explanation of the erratic period variations observed in some of the RR Lyrae variables in the globular clusters. (auth)
Experimental results are presented on the quasi-statistic polarization reversal and on the effect of high dc electric field on the behaviour of LiNH_4SO_4 and LiND_4SO_4 monocrystals, namely in the vicinity of the II-III phase transformation.
A comparison was made of the advantages and disadvantages of two codes, SAND-II and FERRET, for determining the neutron flux spectrum and uncertainty from experimental dosimeter measurements as anticipated in the FFTF Reactor Characterization Program. This comparison involved an examination of the methodology and the operational performance of each code. The merits of each code were identified with respect to theoretical basis, directness of method, solution uniqueness, subjective influences, and sensitivity to various input parameters.
The answer to the title is ''NO''. The authors investigate the low energy particle spectra of type-II superstring theory after compactification to 4 dimensional space-time by means of the super Kac-Moody algebra as well as the twisted super Kac-Moody algebra. They show that there is no solution containing all of the particle contents in the standard model.
Several closely related Mn(II)-oxidizing alpha-Proteobacteria were isolated from very different marine environments: strain SI85-9A1 from the oxic/anoxic interface of a stratified...Full Text Available
The nature of binding of Ru(phen) 2+ (I), Ru(bipy) 2+ (II), Ru(terpy) 2+ (III) (phen = 1,10-phenanthroline, bipy 3 = 2,2'-bipyridyl, 3 terpy = 2,2'2," - 2 terpyridyl) to DNA, poly[d(G-C)] and poly[d(A-T)]...Full Text Available
Radiation doses to workers at the Manhattan Engineer District (MED) and US Atomic Energy Commission (AEC) sites due to external irradiation during 1940--1960 are reviewed. Categorized radiation dose data were available from AEC annual reports for some years. Annual individual radiation dose data for ten MED/AEC sites for all years were available from the US Department of Energy`s (DOE) Comprehensive Epidemiologic Data Resource (CEDR). These data are combined to produce an estimate of external collective dose equivalent to 172,000 person-rems (1720 person-Sv) for 1940--1960. During this period there were 41 overexposures, 19 criticality incidents, and 3 deaths due to acute radiation syndrome among several hundred thousand workers.
The GSD must be considered as a quantity by means of which the risk in a given population can be described exclusively in terms of genetic risk. In cases of a simultaneous increase in the rate of examinations, the GSD may lead to a misinterpretation of the population exposure, suggesting a decreasing trend, although there is an actual increase in the somatic radiation exposure. It is recommended to indicate not only the GSD but also the amount of somatic radiation exposure of the population for each specific source when comparing and evaluating radiation exposures from different sources. Although the somatically significant dose formally would be suited as a complement to the GSD, it is recommended to use the effective per caput dose equivalent. It must be pointed out that the application of the concept of effective dose equivalent is only appropriate for comparative evaluations of the population exposure to different ...
Scanning spreading resistance microscopy (SSRM) has been applied to study focused ion beam (FIB) induced damage in silicon in dependence on ion irradiation doses from 10"1"2 cm"-"2 to 2#centre dot#10"1"6 cm"-"2. Starting from the lowest dose, SSRM detects increasing spreading resistance (SR) with increasing dose. For doses from 2#centre dot#10"1"3 cm"-"2 to 4#centre dot#10"1"4 cm"-"2, a slight decrease of SR is measured whereas for higher doses SR again slightly increases. The results are explained by physical effects like decreased carrier mobility due to increased scattering, amorphisation of silicon and precipitation of implanted Ga ions. The results clearly prove that SSRM is well suited for the fast detection of ion beam induced damage with high lateral resolution.
Objective: To investigate the X-ray radiation dose patients dealt with the hepatic intervention. Methods: Thermoluminescence and tissue-equivalent anthropomorphic phantom were used to measure the X-ray radiation dose in patients dealt with the hepatic intervention in 85 patients. Results: The peak skin dose in the patients who accepted hepatic intervention was from 179.95 to 1759.00 mGy, effective dose approached 29.22 mSv (male), 29.27 mSv (female). Conclusion: Hepatic intervention is now regarded as an important therapeutic method for liver cancer. However, the patients were exposed to too much X-ray radiation during interventional procedures. Some more effective protection should be taken to decrease the X-ray radiation dose accepted by patients. (authors)
Allogeneic stem-cell transplantation (SCT) is potentially curative therapy in AML by providing both dose-intensive chemo-radiotherapy and induction of graft-versus-leukemia (GvL) effect. Historically, more emphasis was given to the intensity of conditioning. Over the last decade the pendulum turned more towards induction of GvL as the primary goal. A plethora of non-myeloablative (NMA) and reduced-intensity conditioning regimens (RIC) were introduced trying to reduce transplant-related toxicities and allow SCT in elderly and medically infirm patients. In addition, reduced-toxicity myeloablative regimens (RTC) based on fludarabine and myeloablative alkylating-agent doses were designed to allow safer administration of dose-intensive therapy. Conditioning dose-intensity is highly correlated w...
A computer-based beam dosimetry measurement system for boron neutron capture therapy provides accurate, sensitive, and rapid readout and recording of all beam dose components, epithermal and thermal neutron flux, and gamma-ray dose rate. This dosimetric system includes input from the characterization of the epithermal neutron beam developed at the Massachusetts Institute of Technology, actual BPA pharmacokinetic data from a specific human subject being irradiated, output of MacNCTPLAN, a treatment planning system developed by the authors group, and input from the five on-line beam detectors. The purpose of this system and associated readout systems is to ensure that the desired dose is delivered to the subject within acceptable dose tolerances, e.g., {+-}5% of the target dose, and that any perturbations in the neutron beam that may occur during irradiation can be rapidly evaluated ...
A computer-based beam dosimetry measurement system for boron neutron capture therapy provides accurate, sensitive, and rapid readout and recording of all beam dose components, epithermal and thermal neutron flux, and gamma-ray dose rate. This dosimetric system includes input from the characterization of the epithermal neutron beam developed at the Massachusetts Institute of Technology, actual BPA pharmacokinetic data from a specific human subject being irradiated, output of MacNCTPLAN, a treatment planning system developed by the authors group, and input from the five on-line beam detectors. The purpose of this system and associated readout systems is to ensure that the desired dose is delivered to the subject within acceptable dose tolerances, e.g., #+-#5% of the target dose, and that any perturbations in the neutron beam that may occur during irradiation can be rapidly evaluated ...
Despite the widely recognized usefulness of the AAPM TG-43 brachytherapy dose calculation formalism, a straightforward application of this approach to describe the dose distribution about intravascular line sources as proposed by TG-60 may be difficult or even impossible, especially when these line sources emit low-energy photons or beta particles. The causes of these limitations are investigated and illustrated by means of some numerical examples. In order to solve the observed limitations an adapted formalism is proposed, intended specifically for the description of the dose rate distribution about line sources but conceptually similar to the TG-43/TG-60 formalism. Several examples are presented to illustrate the usefulness of the proposed line source dose calculation formalism.
Since the fluoroscopic image during nasoenteral tube placements is used for guidance and not for diagnosis, a lower contrast image with increased quantum mottle can be easily tolerated. The three methods to reduce the radiation dose rate investigated consisted of removing camera from the image intensifier output phosphor, and setting the fluoroscopic mA to the minimum value so that the kVp could be maximized. Fluoroscopic frozen video frames of a clinical tube insertion comparing the images with and without the dose-saving techniques are presented. Measurements of the radiation dose rates using a Plexiglas phantom show that the dose for patient and staff during fluoroscopic-guided nasoenteral tube placements can be reduced by over a factor of 10 without significantly adversely affecting the actual placement procedure. (author).
It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.
After having discussed the peculiarities of children in X-ray diagnosis the application of the effective as well as the mean equivalent doses as to the determination of the radiation exposure in children is represented. In using computerized tomograms to determine position and extent of an organ the exposure by repeated X-raying was calculated referring to the entrance dose. Entrance dose measurements for all types of X-ray examination in hospitals and ascertainments of the frequency of radiograms in 20 X-ray departments were used to determine per capita and collective doses, resp., in several age groups. Alltogether, the per capita dose of children in the GDR amounts to 30% of that of adults. Conclusions were drawn as to taking measures to further reduction of radiation exposure: (1) Technical measures, such as positioning of patients, shielding of organs, quality assurance; (2) ...
In 16 female patients wick colpourethrocystography was performed directly successively with large-size films as well as medium-size films (intensifier fluorography). The area exposure products were measured by a dosemeter closely attached to the diaphragm and separately for radiography and fluorography, resp. Surface doses as well as organ doses were calculated according to Rosenstein. The average radiatin doses of the active bone marrow were 6.03 mGy for examination with large-size films and 1.27 mGy for fluorography; the average gonadal doses were 7.45 mGy and 1.56 mGy, resp. The portion of fluoroscopy in radiation exposure amounted to 14.8% in large-size film examination, but was 74.0% in medium-size examination. Thus the comparative results revealed a significant reduction of the patient's radiation dose by application of intensifier fluorography in colpourethrocystography.
This report summarizes the progress made on the development of an integrated multistage fluidized bed retorting process (KENTORT II) during the period of October 1, 1992 through September 30, 1993 under Cooperative Agreement No. DE-FC21-90MC27286 with the Morgantown Energy Technology Center, US Department of Energy. The KENTORT II process includes integral fluidized bed zones for pyrolysis, gasification, and combustion of the oil shale. The purpose of this program is to design and test the KENTORT II process at the 50-lb/hr scale. The PDU was assembled, instrumented and tested during this fiscal year. Along with the major activity of commissioning the 50-lb/hr retort, work was also completed in other areas. Basic studies of the cracking and coking kinetics of model compounds in a fixed bed reactor were continued. Additionally, as part of the effort to investigate niche market applications for KENTORT ...
The properties of the highest velocity ejecta of normal Type Ia supernovae (SNe Ia) are studied via models of very early optical spectra of 6 SNe. At epochs earlier than 1 week before maximum, SNe with a rapidly evolving Si II 6355 line velocity (HVG) have a larger photospheric velocity than SNe with a slowly evolving Si II 6355 line velocity (LVG). Since the two groups have comparable luminosities, the temperature at the photosphere is higher in LVG SNe. This explains the different overall spectral appearance of HVG and LVG SNe. However, the variation of the Ca II and Si II absorptions at the highest velocities (v >~ 20,000 km/s) suggests that additional factors, such as asphericity or different abundances in the progenitor white dwarf, affect the outermost layers. The C II 6578 line is marginally detected in 3 LVG SNe, suggesting that LVG undergo less intense burning. The ...
A series of NHC silver(I), mercury(II) and palladium(II) complexes, [(1,3-diethylbimy)6Ag4I3]I (2), [(1-benzyl-3-picolylbimy)Ag2Br2]n (3), [(1-benzyl-3-picolylbimy)HgI(CH2CN)]2 (4), {[(1-picolyl-3-npropylbimy)2Hg][Hg2I6]}n (5) and [(1,3-dipicolylbimy)PdCl]Cl (6), as well as one anionic complex [1,3-diethylbimidazolium]2[HgI4] (1) (bimy=benzimidazol-2-ylidene), have been prepared and characterized. Interestingly, a wind wheel-like Ag4I3 arrangement in 2 is formed, 1D polymeric chain containing 12-membered macrometallocycles and quadrangle Ag2Br2 units in 3 is generated, and the a-carbon atom of deprotonated acetonitrile ([CH2CN]-) in 4 participates in coordination with mercury(II) atom. In the crystal packings of complexes 1-6, 2D supramolecular layers or 3D supramolecular architectures are...
A number of amines can be employed for all volatile treatment (AVT) of steam generator (SG) systems of nuclear power reactors. These amines form complexes with Cu{sup 2+} and Ni{sup 2+} ions which come into water due to corrosion. The redox reactions of a number of Cu(II)-AVT amine complexes and the stability of the transient species formed have been studied by pulse radiolysis technique. Rate constants for the reaction of e{sub aq}{sup -} with a number of Cu(II)-amine complexes have been determined by following the decay of e{sub aq}{sup -} absorption. Stability of Cu(I)-amine complexes was studied by following the kinetics of the bleaching signal formed at the {lambda}{sub max} of the Cu(II) amine complex. Except for Cu(I)-triethanolamine complex all other Cu(I)-amine complexes were found to be stable. One-electron oxidation of Cu(II) amine complexes was studied using azidyl radicals for the oxidation ...
Coutinho MF, Encarnao M, Gomes R, da Silva Santos L, Martins S, Sirois-Gagnon D, Bargal R, Filocamo M, Raas-Rothschild A, Tappino B, Laprise C, Cury GK, Schwartz IV, Artigals O, Prata MJ, Alves S. Origin and spread of a common deletion causing mucolipidosis type II: insights from patterns of haplotypic diversity. Mucolipidosis II (ML II alpha/beta), or I-cell disease, is a rare genetic disease in which activity of the uridine diphosphate (UDP)-N-acetylglucosamine:lysosomal enzyme N-acetylglucosamine-1-phosphotransferase (GlcNAc-phosphotransferase) is absent. GlcNAc-phosphotransferase is a multimeric enzyme encoded by two genes, GNPTAB and GNPTG. A spectrum of mutations in GNPTAB has been recently reported to cause ML II alpha/beta. Most of these mutations were found to be private or rare. ...
We study the condensation of localized closed string tachyons in C{sup 3}/Z{sub N} non-supersymmetric noncompact orbifold singularities via renormalization group flows that preserve supersymmetry in the worldsheet conformal field theory and their interrelations with the toric geometry of these orbifolds. We show that for worldsheet supersymmetric tachyons, the endpoint of tachyon condensation generically includes 'geometric' terminal singularities (orbifolds that do not have any marginal or relevant Kahler blowup modes) as well as singularities in co-dimension two. Some of the various possible distinct geometric resolutions are related by flip transitions. For Type II theories, we show that the residual singularities that arise under tachyon condensation in various classes of Type II theories also admit a Type II GSO projection. We further show that Type II orbifolds entirely devoid of ...
Our studies have shown that endotoxin intratracheally instilled into the rat lung induces proliferation of alveolar type II cells. In that study, the alveolar type II cells. In that study, the alveolar type II cell hyperplasia occurred 2 d after instillation of endotoxin and persisted for a further 2 d. After hyperplasia, the lung remodeled and returned to a normal state within 24-48 h. Understanding the mechanisms involved in the remodeling process of this transient hyperplasia may be useful to identify molecular changes that are altered in neoplasia. The purpose of the present study was to corroborate induction of epithelial cell hyperplasia by endotoxin and to delineate mechanisms involved in tissue remodeling after endotoxin-induced alveolar type II cell hyperplasia. In conclusion, immonostaining with cyclin D1 and cytokeratin shows that endotoxin induced epithelial cell proliferation and resulted ...
Two overlapping cDNA clones encoding human DNA topoisomerase II were identified by two independent methods. In one, a human cDNA library in phage {lambda} was screened by hybridization with a mixed oligonucleotide probe encoding a stretch of seven amino acids found in yeast and Drosophila DNA topoisomerase II; in the other, a different human cDNA library in a {lambda}gt11 expression vector was screened for the expression of antigenic determinants that are recognized by rabbit antibodies specific to human DNA topoisomerase II. The entire coding sequences of the human DNA topoisomerase II gene were determined from these and several additional clones, identified through the use of the cloned human TOP2 gene sequences as probes. Hybridization between the cloned sequences and mRNA and genomic DNA indicates that the human enzyme is encoded by a single-copy gene. The location of the gene was mapped to ...
The ability of white-rot fungus, Pycnoporus sanguineus to adsorb copper (II) ions from aqueous solution is investigated in a batch system. The live fungus cells were immobilized into Ca-alginate gel to study the influence of pH, initial metal ions concentration, biomass loading and temperature on the biosorption capacity. The optimum uptake of Cu (II) ions was observed at pH 5 with a value of 2.76 mg/g. Biosorption equilibrium data were best described by Langmuir isotherm model followed by Redlich-Peterson and Freundlich models, respectively. The biosorption kinetics followed the pseudo-second order and intraparticle diffusion equations. The thermodynamic parameters enthalpy change (10.16 kJ/mol) and entropy change (33.78 J/mol K) were determined from the biosorption equilibrium data. The FTIR analysis showed that -OH, -NH, C-H, C=O, -COOH and C-N groups were involved in the biosorption of Cu (II) ions onto immobilized ...
Radio-biologists have pointed out a novel radiobiological phenomenon observed in many tumor and normal cell lines: hyper-radiosensitivity to very low-dose (H.R.S.) followed by induced radioresistance (I.R.R.) after a threshold dose of 0.1-0.3 Gy that depends on the cell line. Radioresistance at high dose (i.e. higher than 0.5 Gy) and metastatic potential of tumor cells are likely major factors of failure in radiotherapy. A careful review of literature suggests that: 1) radiotherapy does not increase the metastatic potential of tumor cells; 2) radioresistance at high dose and metastatic potential are not related. However, inside a given tumor cell line, highly metastatic clones may elicit more cells showing H.R.S; or are more radiosensitive at high dose than poorly metastatic ones. Recent data obtained from molecular techniques (comet and immunofluorescence assays) applied to single ...
We have updeated the radiological dose assessment for Enjebi Island at Enewetak Atoll using data derived from analysis of food crops grown on Enjebi. This is a much more precise assessment of potential doses to people resettling Enjebi Island than the 1980 assessment in which there were no data available from food crops on Enjebi. Details of the methods and data used to evaluate each exposure pathway are presented. The terrestrial food chain is the most significant potential exposure pathway and /sup 137/Cs is the radionuclide responsible for most of the estimated dose over the next 50 y. The doses are calculated assuming a resettlement date of 1990. The average wholebody maximum annual estimated dose equivalent derived using our diet model is 166 mremy;the effective dose equivalent is 169 mremy. The estimated 30-, 50-, and 70-y integral whole-body ...
Vildagliptin is a potent and selective dipeptidyl peptidase IV inhibitor in development for the treatment of type 2 diabetes that improves glycemic control by enhancing alpha- and beta-cell responsiveness to glucose. Two open-label, single-dose, randomized, crossover studies in healthy subjects (ages 18-45 years) investigated the dose proportionality of vildagliptin pharmacokinetics (n = 20) and the effect of food (n = 24) on vildagliptin pharmacokinetics. There was a linear relationship (r(2) = 0.999) between vildagliptin doses of 25, 50, 100, and 200 mg and area under the plasma concentration-time curve from time zero to infinity (AUC(0-infinity)) and maximum plasma concentration (C(max)). Dose proportionality was assessed using a statistical power model [X = alpha x (dose)(beta)]. The 90% confidence intervals of the proportionality coefficient, beta, for AUC(0-infinity) ...
The aim of this study was to evaluate the differences in accuracy of dose calculation between 3 commonly used algorithms, the Pencil Beam algorithm (PB), the Anisotropic Analytical Algorithm (AAA), and the Collapsed Cone Convolution Superposition (CCCS) for intensity-modulated radiation therapy (IMRT). The 2D dose distributions obtained with the 3 algorithms were compared on each CT slice pixel by pixel, using the MATLAB code (The MathWorks, Natick, MA) and the agreement was assessed with the ? function. The effect of the differences on dose-volume histograms (DVHs), tumor control, and normal tissue complication probability (TCP and NTCP) were also evaluated, and its significance was quantified by using a nonparametric test. In general PB generates regions of over-dosage both in the lung and in the tumor area. These differences are not always in DVH of the lung, although the Wilcoxon test indicated significant differences ...
It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate dose, two ...
Population doses from diagnostic and therapeutic uses of radiopharmaceuticals have been estimated on the basis of a nation wide survey data on the number of investigations and treatments used radiopharmaceuticals in the nuclear medicine and the annual amount of their activities. The gonad and marrow doses were calculated from published biokinetics data from humans, employing the MIRD method. The resultant annual genetically significant dose from diagnostic and therapeutic uses of radiopharmaceuticals was 0.36 and 0.02 mrad (3.6 and 0.2 #mu#Gy) per person, respectively, with a total 0.38 mrad (3.8 #mu#Gy) per person. The annual per Caput mean bone marrow dose was 2.3 mrad (23 #mu#Gy) for diagnosis and 0.2 mrad (2 #mu#Gy), for therapy. The resultant annual leukemia significant dose was 1.8 mrad (18 #mu#Gy) per person for diagnostic uses and 0.2 mrad (2 #mu#Gy) per person for ...
The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, ...
The calculation of electronn beam dose using an algorithms similar to convolution/superposition methods for photon beams [1,2,3,4] is explored. The distribution of dose deposited by a number of monoenergetic, point-monodirectional electron pencil beams is first determined using the Monte Carlo method [5,6]. These elementary distributions are combined to model distributions that would result from the spectrum of incident energies and angles [6,7] present in a clinical beam. These modified distributions are then stored for use as kernels in the dose calculation. In the case of a homogeneous phantom, the relative fluence distribution is convolved with the stored kernels to obtain thhe dose distributions in 3 dimensions. Since the kernels cannot be assumed to be spatially invariant in a heterogeneous water-like phantom, the dose deposited on paths from the interaction site to all the ...
AIDE (Activity and Internal Dose Estimates) is a software for calculating activities in compartments and committed doses due to occupational exposures, and for performing intake and dose estimates using bioassay data. It has been continuously developed and tested for more than 20 years. Its calculation core has been applied in several situations, like performing all dose estimates due to (137)Cs intakes, which occurred during the Goiania accident in 1987; performing quality assurance of the ICRP Task Group on Dose Calculations regarding calculations of activities in compartments and generation of dose coefficients for adults due to intakes by inhalation, ingestion and injection of several radionuclides; and producing the tables of activities in compartments and dose coefficients using the NCRP Wound Model for the NCRP report. It provides ...
We performed experimental studies on the convolution/superposition method reported in the former companion paper (Iwasaki in Radiol Phys Technol 4, 2011) using 10-MV X-ray beams from open-jaw-collimated fields. The method uses primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. We made a comparison of calculations and measurements in water phantoms and thorax-like phantoms with respect to percentage depth dose curves, tissue???phantom ratio curves, and dose profiles. We made the dose calculation by taking into account the beam-hardening effect with depth and the off-axis radiation-softening effect. We found that the method could be used, in general, for performing accurate dose calculations.
Purpose: Various published reports involving intensity-modulated radiotherapy (IMRT) plans developed using automated optimization (inverse planning) have demonstrated highly conformal plans. These reported conformal IMRT plans involve significant target dose inhomogeneity, including both overdosage and underdosage within the target volume. In this study, we demonstrate the development of optimized beamlet IMRT plans that satisfy rigorous dose homogeneity requirements for all target volumes (e.g., #+-#5%), while also sparing the parotids and other normal structures. Methods and Materials: The treatment plans of 15 patients with oropharyngeal cancer who were previously treated with forward-planned multisegmental IMRT were planned again using an automated optimization system developed in-house. The optimization system allows for variable sized beamlets computed using a three-dimensional convolution/superposition dose ...
With the advent of intensity-modulated radiation therapy (IMRT), the inclusion of heterogeneity corrections is further complicated by the conformal delivery of many small beams forming steep dose gradients. Radiation treatment planning has evolved to take into account even small changes in tissue density so that the dose to tumor can be further optimized. However, different treatment planning systems incorporate different heterogeneity correction algorithms, and it is unclear whether any of these algorithms are superior to others in terms of accurately predicting delivered radiation doses relative to measurement in a clinical setting. The purpose of this study was to determine the accuracy of heterogeneity dose calculations from two widely used IMRT treatment planning systems (Pinnacle and Corvus) against measurement. These two systems handle heterogeneity dose corrections by means ...
In areas where radiation dose monitoring has not been performed, it is essential to use material available in the environment be able to rapidly assess doses to individuals for immediate emergency medical care or for general estimation of the radiological consequences. It was shown that certain types of telephone cards containing microchips have the potential to be used as individual radiation dosimeters in emergency situations to detect doses over 250 mGy by luminescence measurements. In order to understand the dosimetric properties of chip cards, the components obtained from INFINIEON Company at various stages of production were used for luminescence measurements. It is found that the protecting layer used above the chips so called 'globe top' is the main source of radiation induced signal in chip cards. The globe top produced by INFINIEON at that stage is found to contain SiO2 and Epoxy. In order to improve the ...
Full - grown pupae of the cotton leaf worm Spodoptera littorals (Boisd.) were gamma - irradiated with low doses of 25,50,75, or 100 Gy for male line and with 50 or 100 Gy for female line . The effects on reproduction, development and sex ratio were the biological aspects studied among P1,F1,F2 and F 3 generations . Also, the effects of dose accumulation applied grown male pupae through two or three filial generations and the retarded influence on their F1,F2,and F 3 progeny were examined. In another trial the histological examinations for ovaries and testes of irradiated parents and for their generation were made . The F1 males were more sterile than irradiated parental males while F1 females were more fertile than their irradiated parental females. Irradiation of P1 males did not clearly affect neither the percentage of mated females nor the average number of spermatophores per mated female among the individuals of P1,F1,F2 and F 3 ...
In the early period after the Chernobyl accident, analysis of patterns of "1"3"1I exposure of the human thyroid showed that contaminated milk was the basic source of "1"3"1I intake among the inhabitants of Russia. The equipment and techniques used for measurement of the "1"3"1I content in the thyroids of these individuals are described in this work. A model of the "1"3"1I intake, taking into account protective actions, and a method of thyroid dose calculation are discussed. The mean thyroid dose and frequency distributions of the thyroid doses to inhabitants of towns and villages of the Bryansk, Tula and Orel regions of Russia are presented. The mean dose to the thyroids of children living in the villages was 2 to 5 times higher than the dose to adult thyroids; for children living in the towns, the mean dose was 1.5 to 12 times higher. The mean thyroid mass in ...
Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the entrance ...
Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the entrance dose values ...
The number of multislice CT (MSCT) scans performed in polytraumatized children has increased rapidly. There is growing concern regarding the radiation dose in MSCT and its long-term consequences, especially in children. To determine the effective dose to polytraumatized children who undergo whole-body MSCT. A total of 51 traumatized children aged 0-16 years underwent a polytrauma protocol CT scan between November 2004 and August 2006 at our institution. The effective dose was calculated retrospectively by a computer program (CT-Expo 1.5, Hannover, Germany). The mean effective dose was 20.8 mSv (range 8.6-48.9 mSv, SD{+-}7.9 mSv). There was no statistically significant difference in the effective dose between male and female patients. Whole-body MSCT is a superior diagnostic tool in polytraumatized children with 20.8 mSv per patient being a justified mean effective ...
Single doses of lead (trace to 445 mg/kg) were administered per os to suckling and adult mice. Both groups exhibited dose-independent lead retention when doses of 4 to 445 mg/kg were administered. However, developmental differences in the fraction of initial dose (FID) retained were evident for all doses administered. A much larger FID was retained in both age groups following administration of carrier-free "2"0"3Pb. The results are consistent with a mechanism of gastrointestinal lead absorption comprising two or more processes. Developmental differences were also observed in organ lead concentration relative to whole body concentration for kidneys, skull and brain 6 days following lead administration. Lead retentions (relative to whole body retention) in brain and in bone were linearly related to dose of lead administered in both suckling and adult age groups. ...
Effective doses from {sup 210}Po intake with caribou meat were determined for human residents in Baker Lake and Snowdrift in the Northwest Territories of Canada and compared to doses calculated from reported {sup 210}Po tissue activities in Alaskan and British residents. Effective doses were calculated to separate body tissues, using ICRP 60 human weighting factors and the ICRP 30 metabolic model for {sup 210}Po. Baker Lake and Alaskan effective doses were similar at 0.4 mSv y{sup {minus}1} and slightly higher than Snowdrift doses (0.3 mSv y{sup {minus}1}). Alaskan tissue activities indicated higher effective doses to liver, bone surfaces and red marrow and lower doses to spleen than the {sup 210}Po metabolic model (ICRP 1979a) predicts. Effective doses to Baker Lake and Snowdrift caribou and wolves, calculated from ...
This document is the Final Report for the project Introduccion de Mejoras Tecnologicas en el SISCOM II, or Improvements in SISCOM II Technology. It consists of a brief description of the activities carried out during the project, and several Annexes that explain in a deeper way each result. SISCOM II is the main telemetry system currently in use in the Spanish underground coal mining, but it was developed ten years ago and needed a technological update, which was the objective of this project. The aims of the project were: To develop Hardware and Software for the Out stations currently used (maintenance developments) To design new hardware and software, easier to use in the current and new applications of SISCOM II Both objectives were met, although not in the way originally intended. The main results were: In the field of old Out stations update: A new set of boards for the old Out stations was ...
The CDF II eXtremely Fast Tracker (XFT) is the trigger processor which reconstructs charged particle tracks in the CDF II central outer tracking chamber. The XFT tracks are also extrapolated to the electromagnetic calorimeter and muon chambers and are associated to electromagnetic clusters and muon stubs to generate trigger electron and muon candidates. The steady increase of the Tevatron instantaneous luminosity and the resulting higher occupancy of the chamber demanded an upgrade of the original system, which performed tracking only in the transverse plane of the chamber and was consequently affected by a significant level of fake tracks. In the upgraded XFT, tracking is reinforced by using additional data from the stereo layers of the chamber to reduce the level of fake tracks and to perform three-dimensional track reconstruction. A review of this upgrade is presented.
Feasibility Study-II examined a high-performance Neutrino Factory providing 1 x 10{sup 20} neutrinos per year aimed at a long-baseline detector. The Study was sponsored jointly by BNL and the Neutrino Factory and Muon Collider Collaboration ration (MC) and is based on a 1 MW proton driver operating at 24 GeV, i.e., an upgraded version of the AGS accelerator. Compared with the earlier FNAL-sponsored study (Feasibility Study-I), there is a sixfold improvement in performance. Here we describe details of the implementation of Study-II concepts and discuss their efficacy. Alternative approaches that will be pursued in follow-on R and D activities are also described briefly.
Cu(II)-ATSM continues to be investigated, both in the laboratory and in the clinic, as a tumor hypoxia imaging agent. However, meaningful interpretation of these images requires a more complete understanding of the mechanism by which the tracer is trapped within the cell. Cu(II)-ATSM is a simple molecule and its biochemical interaction with cells is similarly simple, mainly based upon redox chemistry. Here we suggest that the trapping mechanism is biphasic. The first phase is a reduction/oxidation cycle involving thiols and molecular oxygen. This can be followed by interaction with proteins in the mitochondria leading to more permanent retention of the tracer. The uptake mechanism is complicated by this second step because of the changes in the cell resulting from hypoxia, such as an incre...
The distribution of the alkaline earth elements strontium and barium between the solid phases of phosphates of transition elements of group 4 and chloride melts was studied. The distribution coefficients of strontium and barium were found at T = 700-800/sup 0/C. Phosphates of the type NaM/sub 2//sup (IV)/(PO/sub 4/)/sub 3/, where M/sub (IV)/ represents titanium, zirconium, and hafnium, were used as the solid phases. It was established that there is an enrichment of the precipitates with the distributed components. The distribution coefficient depends on the nature of the solid phase and the temperature. It was suggested that M/sup (II)/ x M/sub 4//sup (IV)/(PO/sub 4/)/sub 6/ is formed in processes of distribution, where M/sup (II)/ represents Sr, Ba.
Raman and infrared spectroscopy of para-H{sub 2} to pressures in excess of 200GPa and to 8K using new ultrapure synthetic diamond anvils reveals numerous new vibrational excitations in the three high-pressure phases. Highly resolved Raman-active librons indicate differences in orientational ordering between phasesII and III, including evidence for changes within phaseII. The librons in phaseIII are strongly pressure dependent and reflect a substantial increase in ordering with pressure. Multiple vibrons in all three phases (I, II, and III) are observed. The results place new bounds on predicted crystal structures and dynamics of the dense molecular solid. {copyright} {ital 1997} {ital The American Physical Society}
The EXAFS spectra of the platinum(III) complexes Pt/sub 4/(OAc)/sub 10/(OH)/sub 2/ (I) and Pt/sub 4/ (OAc)/sub 4/(OH)/sub 8/(H/sub 2/O)/sub 2/ (II) have been investigated. It has been found by a curve-fitting method and with the aid of Fourier transformations that the shortest Pt-Pt distances are 2.61 A in complex I and 2.36 and 2.6 A in II. The values of the bond lengths obtained are consistent with the molecular structures proposed for complexes I and II, which contain skeletons of four platinum atoms in the form of a square or a rectangle, as well as with the known literature data on the lengths of Pt-Pt bonds in Pt(III) complexes.
Purpose Evaluation of the all-trans retinoic acid (t-RA) effects on in vitro maturation (IVM) and in vitro fertilization (IVF) of immature mouse oocytes in the presence and absence of granulosa cell monolayer. Methods Denuded oocytes isolated from mice ovaries and matured in IVM medium alone (Control I), IVM medium in the presence of granulosa cells (Control II), IVM medium with t-RA (Experimental I) and IVM medium simultaneously with t-RA and granulosa cells (Experimental II). After 24?h, matured oocytes were fertilized in T6 medium and their development was followed until the blastocyst stage. Metaphase II oocytes ploidy were evaluated by chromosome counting. Results The t-RA group compared to the control groups showed no obvious abnormalities. Additionally maturation and embryo developm...
The synthesis, characterization, and some analytical applications of a new triazine resin are described. Separation of group IB, IIB, VIB, and VIIB metal ions from group VIII metal ions is achieved by this PDT-4 resin. Calcium(II) and magnesium(II) are taken up at pH = 6, 0.1 M acetate and are eluted at pH = 6, 0.1 M sodium nitrate. Copper(II) is retained at pH = 6, 0.1 M acetate and pH = 1 hydrochloric acid and is eluted subsequently by 5 M perchloric acid. Molybdenum(VI) is sorbed selectively from 0.1 N sulfuric acid or hydrochloric acid and is eluted in a tight band by 0.1 N sodium hydroxide. Numerous rapid column chromatographic separations are reported using this new resin, including analysis of NBS standard samples.
We study the localized tachyon condensation of non-supersymmetric orbifold backgrounds in their mirror Landau-Ginzburg picture. We first show that the R-charges of chiral primaries increase under the process of condensing the tachyon in the same chiral ring. Then, utilizing the existence of four copies of (2,2) worldsheet supersymmetry, we show that the minimal tachyon mass in twisted sectors increases in CFT and type 0 string and it plays the role of the c-function of the twisted sectors. We also study the GSO projection in detail and show that type II decays to only to type II while type 0 can mix with type 0 and II under the RG-flow.
Summary Background Sorafenib is an oral multikinase inhibitor that blocks cell proliferation via the ERK pathway and angiogenesis via the VEGF pathway. This phase II trial was conducted to determine the efficacy and tolerability of sorafenib for the treatment of patients with metastatic urothelial cancer (UC) who had not had prior chemotherapy for advanced disease. Patients and Methods Seventeen chemo-na?ve UC patients with adequate performance status and organ function were treated with sorafenib 400?mg twice daily on a continuous basis until progression or unacceptable toxicity. The primary endpoint was objective tumor response rate as measured by RECIST criteria. Secondary endpoints included rate of prolonged stable disease (>3?months), time to progression, median and 1?yr survival and ...
Ruthenium(II) and Iridium(III) polypyridyl complexes have been intensively investigated due to their use in energy conversion and light-emitting devices and materials for non-linear optics. Quantum mechanical computer simulations of molecules and materials have become increasingly popular in the scientific community. Along with experimental investigations, such computational analyses can provide complementary information on the electronic and optical properties of transition metal compounds of interest for optoelectronic applications. Here, we provide a unified review of recent work carried out on computational investigations of a large series of Ruthenium(II) and Iridium(III) polypyridyl complexes, discussing the relations between their electronic structure and optical properties and thei...
Tarapur Atomic Power Station Unit-3 and 4 (TAPS -3 and 4) are the 540 MWe reactors. Unit-4 attained first criticality on 06th March 2005 and operated for about 230 effective full power days (EFPD). Unit-3 attained first criticality on 21st May 2006 and operated for about 20 EFPD. With the reactor operation radiation field increases on the Primary Heat Transport system equipments, Moderator system equipments and auxiliary system equipments due to deposition of fission products and activation products in different reactor systems. These dose rates significantly contributes to the external exposure and stations collective dose during reactor operation, refueling operation and maintenance activities. A study was undertaken at TAPS 3 and 4 to identify the system equipments showing the significant dose rates and identify the radionuclides present in the primary heat transport system, Moderator systems, cover gas system and other ...
A brain weight deficit of about 70 mg was induced at doses of approximately 75-mGy and a deficit of 60 mg was induced at 100 mGy. This confirms the effects projected and observed by Wanner and Edwards. Although the data do not demonstrate a clear dose-response relationship between the 75-mGy and 100-mGy groups, the data are statistically consistent with a dose-response effect because of the overlapping confidence intervals. The lack of a statistically significant observation is most likely related to the small difference in doses and the limited numbers of animals examined. There are several factors that can influence the brain weight of guinea pig pups, such as caging and housing conditions, the sex of the animal, and litter size. These should be taken into account for accurate analysis. Dam weight did not appear to have a significant effect. The confirmation of a micrencephalic effect induced x rays ...
Composites based on pure gypsum and polyester-styrene resin have been prepared using various doses of gamma radiation. Some physical properties of the prepared composites and the influence of irradiation dose on it have been studied as: compression strength, hardness, thermal decomposition temperature in nitrogen or oxygen, and the change in weight in aqueous solutions with different pH values. The glass transition temperature of the pure polymer and the composites increases with increasing the irradiation dose up to a plateau, and the glass transition temperature of the pure polymer is lower than that of the composites. The irradiation dose does not seem to affect the decomposition temperature of the pure polymer or the composites significantly and the decomposition temperature in presence of nitrogen is higher than that in presence of oxygen. Increasing the irradiation dose leads ...
Pharmacokinetics is studied, radiation doses to patients when using domestic thallium-201 chloride in diagnosis of the heart ischemic disease is estimated; contribution into the total dose of thallium-201 (1.5 %), thallium-201 (0.2 %) and lead-201 + lead-203 (0.05 %) radionuclide impurities is also determined. Internal doses were estimated for a heterogeneous phantom of a standard man; the calculations were carried out using a computer. Scanning of patients which were treated with radiopharmaceuticals to be diagnosed was carried out using a whole body counter and gamma-chamber. Large intestine, kidneys and thyroid are the critical organs when using thallium-201 chloride. The highest contribution into the dose to organs and the whole body from thallium-200 and thallium-202 impurities being contained in thallium-201, doesn't exceed 8.6 %. The contribution into the dose from lead-201 ...
Despite its great usefulness in the performance of the recording procedures prescribed by the X-Ray Ordinance the dose-area product is much less frequently measured for X-ray exposures than during fluorscopic examinations. The great multitude of measuring units, mainly on account of different scales of the measuring equipments themselves, is a cause of uncertainty in clinical routine and should be eliminated as far as the circumstances would permit. As the determination of the organ dose is relevant only in very few cases and does not necessarily require previous measurements of the dose-area product, these are of limited practical value in the assessment of individual radiation exposures during radiographic examinations. The measurements may, however, be very helpful in determinations of the radiation dose to the total population, if the future retrievability of the values obtained is ensured. In ...
The rate of residual-resistivity increase and the isochronal recovery have been studied on the fcc metals Al, Ni, Cu, Pd, Ag, Pt, and Au irradiated at 4.6 K with reactor neutrons to a dose of about 10"1"9 (fast neutrons)/cm"2. The rate of resistivity increase is nonlinear as a function of irradiation-induced resistivity; computer analysis shows that the data are best fitted with an erxpression having up to third-order terms in #DELTA#rho. There are deviations from simple damage-rate theory in all cases, but an anomalous negative deviation from a linear law (convex curvature) is observed in Ni, Pd, Pt (and Fe). This behavior is most probably caused by a decrease of the specific Frenkel-defect resistivity due to defect clustering, an effect which should contribute in all metals after fast-neutron irradiation to high doses. Saturation values of resistivity and defect concentration as well as recombination volumes have veen obtained more accurately ...
Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin dose distribution, clinical ...
The author studied the conditions needed to routinely estimate the radiation dose in chicken bone by repeated re-irradiation and measuring ESR signals. Chicken meat containing bone was {gamma}-irradiated at doses of up to 3kGy, accepted as the commercially used dose. The results show that points in sample preparation and ESR measurement are as follows: Both ends of bone are cut off and central part of compact bone is used for experiment. To obtain accurate ESR spectrum, marrow should be scraped out completely. Sample bone fragments of 1-2mm particle size and ca.100mg are recommended to obtain stable and maximum signal. In practice, by re-irradiating up to 5kGy and extrapolating data of the signal intensity to zero using linear regression analysis, radiation dose is estimated. For example, in one experiment, estimated doses of chicken bones initially irradiated at 3.0kGy, 1.0kGy, ...
In this paper, we study the effect of the Ge{sup +} preamorphization dose on boron diffusion and on the thermal evolution of end of range (EOR) defects during annealing. Amorphizations were carried out by implanting Ge{sup +} at 150 keV to doses ranging from 1x10{sup 15} to 8x10{sup 15} ions/cm{sup 2}. Boron was subsequently implanted at 3 keV with a dose of 1x10{sup 14} ions/cm{sup 2}. Rapid thermal annealing (RTA) was performed for various time/temperature combinations in nitrogen ambient. Secondary ion mass spectroscopy (SIMS) and transmission electron microscopy (TEM) were used to study boron diffusion and defect evolution, respectively. We have found that after a given annealing, both the defect size and boron diffusivity are independent on the Ge ion dose. Increasing this dose only results in an increase of the defect density. These results are discussed and definitely show ...
In this paper, we study the effect of the Ge"+ preamorphization dose on boron diffusion and on the thermal evolution of end of range (EOR) defects during annealing. Amorphizations were carried out by implanting Ge"+ at 150 keV to doses ranging from 1x10"1"5 to 8x10"1"5 ions/cm"2. Boron was subsequently implanted at 3 keV with a dose of 1x10"1"4 ions/cm"2. Rapid thermal annealing (RTA) was performed for various time/temperature combinations in nitrogen ambient. Secondary ion mass spectroscopy (SIMS) and transmission electron microscopy (TEM) were used to study boron diffusion and defect evolution, respectively. We have found that after a given annealing, both the defect size and boron diffusivity are independent on the Ge ion dose. Increasing this dose only results in an increase of the defect density. These results are discussed and definitely show that EOR defects are involved in a ...
(001) CZ silicon wafers were implanted with arsenic (As{sup +}) at energies of 10--50 keV to doses of 2 {times} 10{sup 14} to 5 {times} 10{sup 15}/cm{sup 2}. All implants were amorphizing in nature. The samples were annealed at 700 C for 16 hrs. The resultant defect microstructures were analyzed by XTEM and PTEM and the As profiles were analyzed by SIMS. The As profiles showed significantly enhanced diffusion in all of the annealed specimens. The diffusion enhancement was both energy and dose dependent. The lowest dose implant/annealed samples did not show As clustering which translated to a lack of defects at the projected range. At higher doses, however, projected range defects were clearly observed, presumably due to interstitials generated during As clustering. The extent of enhancement in diffusion and its relation to the defect microstructure is explained by a combination of factors including ...
(001) CZ silicon wafers were implanted with arsenic (As"+) at energies of 10--50 keV to doses of 2 x 10"1"4 to 5 x 10"1"5/cm"2. All implants were amorphizing in nature. The samples were annealed at 700 C for 16 hrs. The resultant defect microstructures were analyzed by XTEM and PTEM and the As profiles were analyzed by SIMS. The As profiles showed significantly enhanced diffusion in all of the annealed specimens. The diffusion enhancement was both energy and dose dependent. The lowest dose implant/annealed samples did not show As clustering which translated to a lack of defects at the projected range. At higher doses, however, projected range defects were clearly observed, presumably due to interstitials generated during As clustering. The extent of enhancement in diffusion and its relation to the defect microstructure is explained by a combination of factors including surface recombination of point ...
Exposure control at the operating Nuclear Power Station is a major concern. TAPS Unit-4 is the first Pressurized Heavy Water Reactor of 540 MWe electrical capacity. This unit was made critical on March 6, 2005. In-depth review of radiation safety was done to identify the impact of design modification on dose rates at various locations and on the equipment's. Problems encountered in controlling the dose rates in 220 MWe electrical are eliminated by appropriate design modifications. Due to higher capacity of the unit there are design changes in major systems such as reactor core, primer heat transport system, moderator system, reactor regulation and protection systems. Reactor operations and maintenance activities during shut down contributes to exposure of the employees. Based on the experience gained in the operation of 220 MWe, design modifications incorporated in TAPS unit-4 and dose rate measurements carried out at 90 % ...
Careful sample preparation and secondary ion mass spectroscopy have been used to characterize arsenic dose loss to the silicon-oxide interface. Using high resolution x-ray photoelectron spectroscopy for microprofiling, we have directly observed the pileup of arsenic at the silicon dioxide-silicon interface. At least half of the pileup is shown to be on the silicon side of the interface in the first monolayer of silicon. Monolayer chemical oxidation and etching are successfully used to profile this pileup in silicon. This pileup contains most of the arsenic dose loss that occurs during transient enhanced diffusion. This result is crucial to correctly model the dose loss and provides physical justification for using a trap/detrap model at the interface, which is necessary to account for the fact that the arsenic surface concentration remains constant during an anneal and the fact that the dose loss is ...
Careful sample preparation and secondary ion mass spectroscopy have been used to characterize arsenic dose loss to the silicon-oxide interface. Using high resolution x-ray photoelectron spectroscopy for microprofiling, we have directly observed the pileup of arsenic at the silicon dioxide-silicon interface. At least half of the pileup is shown to be on the silicon side of the interface in the first monolayer of silicon. Monolayer chemical oxidation and etching are successfully used to profile this pileup in silicon. This pileup contains most of the arsenic dose loss that occurs during transient enhanced diffusion. This result is crucial to correctly model the dose loss and provides physical justification for using a trap/detrap model at the interface, which is necessary to account for the fact that the arsenic surface concentration remains constant during an anneal and the fact that the dose loss is ...
Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous condition since the GAFCHROMICat..EBT ...
We present a development of the use of the AAPM TG-43 dose formalism applied to "1"3"7Cs gynecological implant sources. The geometry factor, radial dose function, and anisotropy function of a "1"3"7Cs source modeled after the Nuclear Associates 67-809 series stainless steel jacketed tube source were derived following the AAPM TG-43 formalism. The dose rate distribution through the center of the source using the AAPM TG-43 dose formalism is calculated and compared with the calculations obtained using the Sievert summation and Monte Carlo simulation. The three methods resulted in an agreement within less than 5%, or an isodose rate line agreement within 2 mm. We demonstrate that the AAPM TG-43 formalism can be applied to "1"3"7Cs linear sources and is capable of serving as a "1"3"7Cs dose calculation algorithm that can be used for treatment planning purpose.
A convolution/superposition method is proposed for use with primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. It should be noted that the number of energy bins is usually about ten, and that the reconstructed X-ray spectra can reasonably be applied to media with a wide range of effective Z numbers, ranging from water to lead. The study was carried out for 10-MV X-ray doses in water and thorax-like phantoms with the use of open-jaw-collimated fields. The dose calculations were made separately for primary, scatter, and electron contamination dose components, for which we used two extended radiation sources: one was on the X-ray target and the other on the flattening filter. To calculate the in-air beam intensities at po...
Accurate dose calculation in radiation treatment planning is most important for successful treatment. Since human body is composed of various materials and not an ideal shape, it is not easy to calculate the accurate effective dose in the patients. Many methods have been proposed to solve inhomogeneity and surface contour problems. Monte Carlo simulations are regarded as the most accurate method, but it is not appropriate for routine planning because it takes so much time. Pencil beam kernel based convolution/superposition methods were also proposed to correct those effects. Nowadays, many commercial treatment planning systems have adopted this algorithm as a dose calculation engine. The purpose of this study is to verify the accuracy of the dose calculated from pencil beam kernel based treatment planning system comparing to Monte Carlo simulations and measurements especially in inhomogeneous region. ...
The system which is performed the transportation and measurement of drum automatically to measure the surface dose-rate of radioactive waste drum and can inspect place of contaminated sources and precise dose-rate within a drum according to measuring many places equally at the same time has been developed. It is expected that the system be used to minimized radiation exposure of workers and manage the drum effectively according to established at the production facilities as well as the radioactive waste treatment facilities. (author). 7 refs., 9 tabs., 16 figs.
Brachytherapy is a radiotherapeutic modality that makes use of radionuclides to deliver a high radiation dose to a well-defined volume while sparing surrounding healthy structures. At the National Institute for Cancer Research of Genova a High Dose Rate remote afterloading system provides Ir(192) endocavitary brachytherapy treatments. We studied the possibility to use the Geant4 Monte Carlo simulation toolkit in brachytherapy for calculation of complex physical parameters, not directly available by experiment al measurements, used in treatment planning dose deposition models.
The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma distribution was compared to the ...
Standard radiation monitoring has been conducted at Sendai nuclear power station for the purpose of estimation of 'source activity' during refueling outage and evaluation of countermeasures to reduce dose rate. Selected objects of the monitoring are radiation dose rate at maintenance area, radiation field at each equipment and piping, coolant chemistry and plant operation condition. Monitored data indicates that 'source activity' variation can be estimated to some extent using influential factors, and that evaluation of change of loose crud activity, which is presumed to be represented by the dose rate at letdown heat exchanger, is necessary to further explain change in radiation field at main work area. (author).
Polytetrafluoroethylene was obtained by radiation induced polymerization of tetrafluoroethylene in acetone at 195 K. An average diameter of the products was very small compared with commercial one; it was about 0.3 micro-meters. The yield was reached to 100% with a dose of 4 kGy. The crystallinity of the products is decreasing with increasing dose. The products become amorphous, for higher irradiation doses. It was found that PTFE obtained by irradiation of TFE in acetone at 195 K has branching structure. This was demonstrated by means of "1"9F MAS NMR. (Author)
Surface doses received by patients and operators were measured during 30 interventional radiological procedures (ten percutaneous transhepatic biliary drainages, ten percutaneous nephrostomies, ten percutaneous transluminal angioplasties). In addition, organ doses to the patient were determined using an Alderson-Rando phantom. These served as a basis for calculating the so-called somatic dose indices. It was found that the somatic radiation risk to the patient is relatively small despite prolonged periods of fluoroscopy. However, exposure of the hands and lenses of the operator could easily reach the limits thought acceptable while carrying out these procedures with additional angiography. (orig).
Taboada et al. have recently developed a computer model to predict gamma radiation doses to aircrews flying through nuclear-debris clouds. Although the model has the advantages of taking a large number of parameters into account and using the benchmark DELFIC code to model cloud dynamics, it takes up to 20 min for a single run on a mainframe computer. Results from a number of runs have been generalized into empirical formulae. From these results it is possible to estimate worst case gamma radiation doses for complex scenarios using a hand calculator.
There is proposed the nonlinear model of dose dependence saturation of the yield strength on the base of the vacancy and interstitial barrier interaction in this work. Processes of mutual recombination of vacancy and interstitial barriers and formation of vacancy and interstitial clusters are taken into consideration. In the framework of the model, the analytical equations corresponding to the evolution of the barrier densities and yield strength are obtained. It is shown that the yield strength of irradiated materials decreases with the increasing intensity of barrier recombination processes, the dependence being nonlinear. Also it is shown that the model is valid both for low doses and large doses on the stage of radiation hardening.
Building on the concepts of MIRD methods described by Webber, Watson and others at this Symposium on the Dosimetry of Administered Radionuclides, we will now consider how to apply these principles to several experimentally based open-quote macroclose quotes and multicellular models. Specifically, methods to calculate absorbed dose using different types of particulate emission (alpha, beta) with a variety of antibody carriers (IgG, F(ab')_2, Fab) for radioimmunotherapy (RIT) will be reviewed. Additionally, a discussion of direct measurement methods at the multicellular level will reveal the problems of tumor absorbed dose heterogeneity when applied to animal and clinical studies.
Those materials that can be extracted from pine or oak by ether, ethanol, methyl methacrylate (MMA), or benzene--alcohol all act as inhibitors in the #gamma# polymerization of MMA--wood composites. It was found that preirradiation of either the wood or of the wood--monomer combination reduces or eliminates the inhibitory effect. The most practical industrial solution to this problem is to increase the dose, thereby achieving high molecular polymer in the composite. However, the presence of a maximum in the molecular weight--dose curves means that each wood--monomer pair may have a different optimum dose.
Studies on pupal irradiation of Earias vittella Fabricius, were undertaken to determine the optimum dose for sterile and competitive adults. Late pupae were irradiated with gamma radiation doses ranging from 150 to 300 Gy. Emerging adults were normal and without malformation. When males that emerged from irradiated pupae were crossed with normal female, fecundity as well as longevity was comparable to control, but there was drastic reduction in percent egg hatch in all the treatments. However, when females emerging from irradiated pupae were crossed with normal male, there was reduction in the fecundity as well as fertility and this effect was dose dependent. (author).
With the mentioned method to analyse O-tyrosine with HPLC/fluorescence-detection, the irradiation of chicken meat can be determined in a simple and fast way. The formation of o-tyrosine is proportional to the applied dose but because it is also depending on the applied dose rate and the temperature during the irradiation, it is not possible to control the irradiation dose. Since unirradiated chicken can contain little amounts of o-tyrosine and to confirm some results, a second method is needed. Together with one of the other mentioned methods (analysis of the volatiles or esr-spectroscopy) it is possible to recognize irradiated chicken with a high security. (author).
Retention kinetics and tissue partition coefficients for "8"5Kr were determined in rats exposed to known concentrations of "8"5Kr gas. The tissue partition coefficients were used to calculate the relative tissue radiation dose, assuming exposure conditions equivalent to the maximum permissible concentration in air (MPC)a. The estimated radiation dose was highest in adrenals and body fat, about twice the dose estimated for the next highest tissue, ovaries. Saturation and desaturation curves show that the contents of the large intestines have a prolonged desaturation time compared to other samples analyzed.
A dose calculation algorithm for MLC based conformal radiotherapy is described in this paper. The algorithm is formulated by the coordinate of MLC leaves. Verification on the algorithm is made by comparing the dose distributions generated by this algorithm with that generated by a Differential Convolution Superposition algorithm for various regular and irregular fields. The results demonstrate that the present algorithm has suitable accuracy and high computational efficiency, thus it could be useful for the treatment planning process in MLC based conformal radiotherapy, where the workload for interactively or automatically designing the shapes of MLC is heavy. (authors)
Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available
By measuring organ doses with TLD at an Alderson-Rando-phantom it was tested to evaluate the somatic risk for mammographies. Similarly as the genetic risk can be expressed by the genetic significant dose, the somatic risk can be expressed by the somatic significant dose index. The measurement results of the mammography show a large deviation of almost one power of ten with dependence of the chosen technique. In conventional xeroradiography and recording technique with foilless film the somatic radiation risk is the highest. By using amplifying foils in combination with high-sensitive films it is relatively small. Unfortunately the magnitude of the somatic risk in the different mammography techniques is in the ratio reciprocal to the corresponding image quality. At the time being the most favourable technique is mammography with a soft rastering method, although the xeromammography with additional high aluminium-filtering is ...
Drug particle size distribution has a profound impact to the content uniformity in low-dose solid drug products. We derived theoretically the skewness of potency distribution as a function of particle size distribution and target dose. It was demonstrated that both skewness and coefficient of variation diverge simultaneously with inverse square root of the target dose. This scaling relation was observed in recent experiment and was verified by Monte Carlo (MC) simulation, which was employed for the first time to solve for the full potency distribution from a random retrieving model. When tested against the criteria from USP uniformity of dosage units, MC simulation showed a striking anisotropic distribution of the data. This suggests a full-scale consideration of the potency distribu...
Thermoluminescence of inorganic dust extract from herbs and spices has been demonstrated to be a useful method to discriminate irradiated food products as well as to estimate the total dose exposure. The time evolution of infrared stimulated luminescence has been systematically investigated in potassium feldspar and albite minerals subjected to different doses of gamma irradiation (ranging from 0 to 8 kGy). Experimental results reveal a 300-600 nm signal which is greatly intensified for irradiated samples, following the same irradiation dose dependence observed in thermoluminescence. The luminescence intensity disappears after few seconds of illumination, following a time evolution which is proportional to (1 + Bt){sup -P}. The influence of both B and P factors upon the irradiation dose has been systematically analysed. (author)
Although infrared-stimulated luminescence (IRSL) signals in feldspars can be bleached rapidly by sunlight, there could still be a small amount of IRSL signal remaining in sediment grains if they have experienced only relatively short sunlight exposure before deposition. This remaining signal results in a ''remnant dose'' stored in the grain and is important for young samples but negligible for old samples. Several methods have been introduced to detect insufficient bleaching, and some of them can provide information on the extent of the bleaching. Others can only distinguish between samples bleached for a very long time and for a short time. Empirical methods are introduced to evaluate the possible values of equivalent dose accumulated since the grains were deposited. These methods involve the analysis of the equivalent doses and the natural IRSL signals obtained using single-disc dose determination ...
Methylisothiazolinone (MI) used alone is a new preservative causing a high prevalence of contact allergy. The eliciting threshold of MI is unknown. The combination of MI and phenoxyethanol enhances the antimicrobial efficacy of MI.
Context. Cardiovascular medication overdoses can be difficult to treat. Various treatment modalities are currently recommended. Objective. To describe patient outcomes and adverse events of high-dose insulin therapy in consecutive overdose patients in cardiogenic shock after implementation of a high-dose insulin protocol (1-10 U/kg/h, while avoiding or tapering off vasopressors). Methods. This is an observational consecutive case series of patients identified from a registry. Data were collected by retrospective chart review of patients treated by our toxicology service with this protocol from February 2007 until March 2010. Results. Twelve patients were treated with high-dose insulin. The mean age was 36.5 years (SD 11.7). Seven patients had pre-existing vasopressor therapy, and all were ...
During fluoroscopy the examiner is usually protected by a radiation-reducing body shield, leaving the thyroid unprotected. The fact that the thyroid is located in a region of the neck usually covered by the shirt collar led to the idea of designing a tie with lead core, providing easy and ''decorative'' reduction of the radiation dose. Sonographic examinations were carried out in 20 volunteers (10 men, 10 women) to determine the size of the gland and its coverage by such a tie. The reduction of the surface and organ dose was assessed using film dosimetry with scattered radiation, the body of the examiner being simulated by an Alderson phantom. On average 88% of the thyroid gland surface area was covered. Surface dose was reduced to 1%, and organ dose to 10% of the value without the protection tie. (Author).
During fluoroscopy the examiner is usually protected by a radiation-reducing body shield, leaving the thyroid unprotected. The fact that the thyroid is located in a region of the neck usually covered by the shirt collar led to the idea of designing a tie with lead core, providing easy and ''decorative'' reduction of the radiation dose. Sonographic examinations were carried out in 20 volunteers (10 men, 10 women) to determine the size of the gland and its coverage by such a tie. The reduction of the surface and organ dose was assessed using film dosimetry with scattered radiation, the body of the examiner being simulated by an Alderson phantom. On average 88% of the thyroid gland surface area was covered. Surface dose was reduced to 1%, and organ dose to 10% of the value without the protection tie. (Author).
... radiation during clinical therapy and exposures due to radiation accidents or attacks, in which the doses are uncontrolled ... only be used off-label in victims of radiation accidents or attacks. The idea...
Chemically reactive compounds in tissues can be monitored through their products of reaction with biomacromolecules. For the purpose of in vivo dose monitoring, hemoglobin (Hb) has been preferred to...Full Text Available