USSR Report, Electronics and Electrical Engineering.
... comparative analysis is made of the sensitivity of two types of spectrometers: instruments employing coherent spontaneous radiation, and classical ...
1985-04-30
Tolerance analysis of a phase space beam analyzer
The phase space beam analyzer is a measurement instrument that is applied in laser technology to perform analyses of the spatial and angular distribution of rays. We are interested in this instrument as a means to characterize non-coherent light sources. In this context, a closer look at the tolerances of this optical instrument was considered useful. Having a so-called quadrupole lens as a key element, the phase space beam analyzer is a device that features anamorphic optical properties. To describe these anamorphic properties, recurrence was made to a description by extended ray-transfer matrices. This formalism allows for an analysis of the alignment tolerances of the phase space beam analyzer and facilitates a study of the sensitivities of the instrument. The analysis is complemented using numerical ray tracing.
2007-09-01
Instrumental-activation analysis of Mo, Al, Ca, Mn, Cl, Na, and K in soil-plant samples
International Nuclear Information System (INIS)
... activation analysis aluminium 28 calcium 49 chlorine 38 cotton plants li-drifted
Luminescence dating of marine and fluvial sediments ... - GCMD - NASA
INAA (instrumental neutron activation analysis) analyses have been made of subsamples of each OSL (Optically stimulated luminescence) sample, for dosimetry ...
Luminescence and laser transition studies of Dy3+:K-Mg-Al fluorophosphate glasses
International Nuclear Information System (INIS)
Dysprosium ion doped fluorophosphate glasses with compositions of PKMAFDy: (56-x/2) P2O5+17K2O+8Al2O3+(15-x/2)MgO+4AlF3+xDy2O3 (x=0.01, 0.05, 0.1, 1.0 and 2.0 mol%) have been prepared by melt quenching technique and are characterized by optical absorption, emission spectra and fluorescence lifetime measurements. The observed bands in the absorption spectrum are analysed by using free-ion Hamiltonian (HFI) model. The Judd-Ofelt (JO) analysis has been performed and the intensity parameters (??, ?=2, 4, 6) have been evaluated that are used to predict radiative properties. From emission spectra, the effective bandwidth (??eff) and the stimulated emission cross-section (?(?p)) were evaluated. The fluorescence decay from the 4F9/2 level of Dy3+ ions have been measured by monitoring the intense 4F9/2#->#6H13/2 transition (573 nm). The lifetimes (?) are found to decrease with increasing concentration due to concentration quenching. The decay curves are single ...
2009-02-28
A simple system of instruments for radionuclide X-ray fluorescence analysis in nonferrous metallurgy
International Nuclear Information System (INIS)
Proceeding from commercially available instruments, a simple measuring system has been established, which renders possible fast and simple discontinuous analysis of individual elements. This measuring system is described, giving some examples of utilization in nonferrous metallurgy (mining, ore dressing, metallurgical treatment), and specific details, such as error of measurement, ranges of measurement and limits of utilization. (author).
1979-01-01
Vibration test report on the instrumented capsule for fuel irradiation test
Energy Technology Data Exchange (ETDEWEB)
The fluid-induced vibration level of instrumented capsule, which was manufactured for fuel irradiation test at the reactor core of HANARO, was investigated. For this purpose, the instrumented capsule was loaded at the OR site of the HANARO design verification test facility that could simulate identical flow condition as the HANARO core. Then, vibration signals of the instrumented capsule subjected to various flow conditions were measured by using vibration sensors. In time domain analysis, maximum amplitudes and RMS values of the measured acceleration and displacement signals were obtained. By using frequency domain analysis, frequency components of the fluid-induced vibration were analyzed. In addition, natural frequencies of the instrumented capsule were obtained by performing modal test. The frequency analysis results showed that the ...
2003-01-01
On-line analysis of chemical composition using an FT-Raman spectrometer in the near-ir
Newly commercialized Fourier transform Raman spectroscopic instrumentation provides a simpler alternative for vibrational spectroscopic analysis. Instrument vendors currently design for laboratory use, but there are many potential process applications of these stable, easy to use instruments. Raman spectroscopy is highly suited to analysis of aqueous samples. Near infrared excitation minimized fluorescence interference and allows for remote operation via fiber optic probes. The Department of Energy has funded research at the Measurement and Control Center to establish the utility of this method for on-line composition analysis in distillation columns. Laboratory evaluation and instrument employs an air-cooled laser and a thermoelectrically cooled detector. The device is mounted on a three by foot cart for convenient location in control ...
1992-01-01
Energy Technology Data Exchange (ETDEWEB)
The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) refers to a set of several microcomputer programs that were developed to create and analyze probabilistic risk assessments (PRAs), primarily for nuclear power plants. The Fault Tree, Event Tree, and Piping and Instrumentation Diagram (FEP) editors allow the user to graphically build and edit fault trees, and event trees, and piping and instrumentation diagrams (P and IDs). The software is designed to enable the independent use of the graphical-based editors found in the Integrated Reliability and Risk Assessment System (IRRAS). FEP is comprised of three separate editors (Fault Tree, Event Tree, and Piping and Instrumentation Diagram) and a utility module. This reference manual provides a screen-by-screen guide of the entire FEP System.
1994-07-01
Design of APhF-IH Linac for a Compact Medical Accelerator
The design of a small injection linac for a compact medical synchrotron is discussed. The linac design is based on interdigital H-type (IH) drift-tube structure with alternative phase focusing (APhF). A high acceleration rate and an absence of magnetic lenses inside drift-tubes reduce the cost and length of APhF-IH linac in comparison with HIMAC linac based on Alvarez structure with magnet quadrupoles inside drift-tubes. To reduce effects of emittance growth, the RFQ structure is used in front of the APhF linac. In such linac layout, the current transmission of a carbon beam can reach up to 90-100%. In this report, the basic parameters of whole linac are presented, while the design of APhF structure is considered in details. Two reference designs of 4 MeV/u 200 MHz APhF linacs with different voltage distributions along the whole tank have been generated and analyzed numerically. For the first design, a constant voltage distribution along the ...
2003-01-01
FFTF core and primary sodium circuit instrumentation
International Nuclear Information System (INIS)
Plans, engineering parameters, and some test results for several FFTF core and primary sodium circuit instrument systems are presented. The systems discussed include temperature, flow, pressure, leak detectors, level sensors, fuel failure monitoring, sodium impurity analysis and cover gas monitors. Since many of these instruments are similar to those used in other fast reactors around the world, only a brief description is presented for these systems. Results of recent demonstration tests of the FFTF Under-Sodium Viewing and Ranging system are also presented. (U.K.).
Energy Technology Data Exchange (ETDEWEB)
Pyrheliometric methods are described (particularly methods for measuring the solar constant), and theoretical and experimental studies in this field are surveyed and systematized. Particular attention is given to the analysis of instruments intended for pyrheliometers used as standards, reference instruments, and solar-constant meters is examined, and consideration is given to methods for determining the thermal-radiation properties of absorbing coatings and methods for calculating the absorption coefficients of cavity receivers.
1981-01-01
Instrumentation and control improvements at Experimental Breeder Reactor II
Energy Technology Data Exchange (ETDEWEB)
The purpose of this paper is to describe instrumentation and control (I C) system improvements at Experimental Breeder Reactor 11 (EBR-11). The improvements are focused on three objectives; to keep the reactor and balance of plant (BOP) I C systems at a high level of reliability, to provide diagnostic systems that can provide accurate information needed for analysis of fuel performance, and to provide systems that will be prototypic of I C systems of the next generation of liquid metal reactor (LMR) plants.
1993-01-01
Instrumentation and control improvements at Experimental Breeder Reactor II
Energy Technology Data Exchange (ETDEWEB)
The purpose of this paper is to describe instrumentation and control (I&C) system improvements at Experimental Breeder Reactor 11 (EBR-11). The improvements are focused on three objectives; to keep the reactor and balance of plant (BOP) I&C systems at a high level of reliability, to provide diagnostic systems that can provide accurate information needed for analysis of fuel performance, and to provide systems that will be prototypic of I&C systems of the next generation of liquid metal reactor (LMR) plants.
1993-03-01
Discriminating between a Stochastic Gravitational Wave Background and Instrument Noise
The detection of a stochastic background of gravitational waves could significantly impact our understanding of the physical processes that shaped the early Universe. The challenge lies in separating the cosmological signal from other stochastic processes such as instrument noise and astrophysical foregrounds. One approach is to build two or more detectors and cross correlate their output, thereby enhancing the common gravitational wave signal relative to the uncorrelated instrument noise. When only one detector is available, as will likely be the case with the Laser Interferometer Space Antenna (LISA), alternative analysis techniques must be developed. Here we show that models of the noise and signal transfer functions can be used to tease apart the gravitational and instrument noise contributions. We discuss the role of gravitational wave insensitive "null channels" formed from particular combinations ...
2010-01-01
Instrumentation and Controls Division progress report, September 1, 1980-July 1, 1982
Energy Technology Data Exchange (ETDEWEB)
Activities are reported by the Reactor Systems Section, Research Instrument Section, and the Measurement and Controls Engineering Section. Reactor system activities include dynamic analysis, survillanc and diagnostic methods, design and evaluation, detectors, facilities support, process instrumentation development, and special assignments. Activities in the Research Instrument Section include the Navy-ORNL RADIAC development program, advanced ..gamma.. and x ray detector systems, neutron detection and subcriticality measurements, circuit development, position-sensitive detectors, stand-alone computers, environmental monitoring-detectors and systems, plant security, engineering support for fusion energy division, engineering support for accelerator physics, and communications: radio, closed-circuit tv, and computer. Activities in the Measurement and Controls Engineering Section include the AVLIS program; ...
1982-12-01
Can treadmill walking be used to assess propulsion generation?
UK PubMed Central (United Kingdom)
Instrumented treadmills offer significant advantages for analysis of human locomotion, including recording consecutive steady-state gait cycles, precisely controlling walking speed, and avoiding...Full Text Available
2008-01-01
We report on the spectral cross-calibration results of the Konus-Wind, the Suzaku/WAM, and the Swift/BAT instruments using simultaneously observed gamma-ray bursts (GRBs). This is the first attempt to use simultaneously observed GRBs as a spectral calibration source to understand systematic problems among the instruments. Based on these joint spectral fits, we find that 1) although a constant factor (a normalization factor) agrees within 20% among the instruments, the BAT constant factor shows a systematically smaller value by 10-20% compared to that of Konus-Wind, 2) there is a systematic trend that the low-energy photon index becomes steeper by 0.1-0.2 and Epeak becomes systematically higher by 10-20% when including the BAT data in the joint fits, and 3) the high-energy photon index agrees within 0.2 among the instruments. Our results show that cross-calibration based on joint spectral ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
The use of the focused ion beam (FIB) systems has increased to a high level in recent years. The imaging, milling, and deposition capabilities of the FIB make it the ideal instrument for e.g., site-specific failure analysis, specimen preparation and nano-machining. Ion channelling contrast allows for selective imaging of polycrystalline and polyphase microstructures. In addition, the FIB and CrossBeam registered instruments are unique stand-alone analytical tools. Their vast capabilities have enabled numerous applications into the semiconductor and materials sciences applications. These integrated CrossBeam registered Tools enable the observation and direct control of the FIB operation in real time. In addition to the improved accuracy and resolution the electron beam adds analytical capabilities as STEM, EDS and EBSP to the instruments. To ensure a safe and reliable operation of the ...
2005-07-01
British Library Electronic Table of Contents (United Kingdom)
In recent years, the concept of sustainable consumption (SC) has received increased attention. Overconsumption in industrialized countries still presents major challenges to achieving sustainable development goals despite the global economic crisis. This paper offers an in-depth analysis of national influences on consumption patterns in the Republic of Ireland, focusing in particular on the role of governance in the design of policy instruments for sustainable consumption. It is argued that country-specific political conditions and policy frameworks fundamentally shape everyday household consumption. After an initial discussion of the effectiveness of three key types of policy instruments?legislative, economic, communicative?the paper compares SC policy making and implementation in Ireland...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Elemental analysis of some medicinal plants used in the Indian Ayurvedic system was performed by employing instrumental neutron activation analysis (INAA) and atomic absorption spectroscopy (AAS) techniques. The samples were irradiated with thermal neutrons in a nuclear reactor and the induced activity was counted by gamma ray spectrometry using an efficiency calibrated high resolution high purity germanium (HPGe) detector. Most of the medicinal plants were found to be rich in one or more of the elements under study. The variation in elemental concentration in same medicinal plants samples collected in summer, winter and rainy seasons was studied and the biological effects of these elements on human beings are discussed. (orig.)
2009-07-01
British Library Electronic Table of Contents (United Kingdom)
Nerve growth factor (NGF), a survival factor for neurons enforces pain by sensitizing nociceptors. Also in the pancreas, NGF was associated with pain and it can stimulate the proliferation of pancreatic cancer cells. Hepatic stellate cells (HSC) respond to NGF with apoptosis. Transforming growth factor (TGF)-b, one of the strongest pro-fibrogenic activators of pancreatic stellate cells (PSC) induced NGF and its two receptors in an immortalized human cell line (ihPSC) and primary rat PSC (prPSC) as determined by RT-PCR, western blot, and immunofluorescence. In contrast to HSC, PSC expressed both NGF receptors, although p75NTR expression was weak in prPSC. In contrast to ihPSC TGF-b activated both Smad signaling cascades in prPSC. NGF secretion was diminished by the activin-like kinase (ALK)...
2009-01-01
On new methods for standardization of samples in activation analysis of biological materials
International Nuclear Information System (INIS)
New standardization techniques of samples in multielement instrumental neutron-activation analysis (INAA) of biological materials (BM) are considered. New methodical developments of sample preparation techniques, BM tableting, creation of comparison standards and standardization of packing material are suggested. Correlated data on concentration of different elements in standard specimens-comparison standards are presented for mass INAA, that is: for phenol-formaldehyde resin-base and human blood-base synthetic standards. 7 refs.; 3 tabs.
1988-06-26
FY 1999 Laboratory Directed Research and Development annual report
Energy Technology Data Exchange (ETDEWEB)
A short synopsis of each project is given covering the following main areas of research and development: Atmospheric sciences; Biotechnology; Chemical and instrumentation analysis; Computer and information science; Design and manufacture engineering; Ecological science; Electronics and sensors; Experimental technology; Health protection and dosimetry; Hydrologic and geologic science; Marine sciences; Materials science; Nuclear science and engineering; Process science and engineering; Sociotechnical systems analysis; Statistics and applied mathematics; and Thermal and energy systems.
2000-06-13
Energy Technology Data Exchange (ETDEWEB)
The applicability of the radionuclide X-ray fluorescence analysis (RXFA) for qualitative and quantitative evaluation of environmental plant samples is discussed and examples of determination of Mn, Fe, Ni, Cu, Zn, Pb in samples of apple trees are given. The instrumentation, the standard and sample preparation are also presented.
1982-12-01
Replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory
Energy Technology Data Exchange (ETDEWEB)
The DOE-Idaho Operations Office (DOE-ID) has prepared an environmental assessment (EA) on the replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory at the Idaho National Engineering Laboratory (INEL). The purpose of this project is to replace the existing Health Physics Instrumentation Laboratory (HPIL) with a new facility to provide a safe environment for maintaining and calibrating radiation detection instruments used at the Idaho National Engineering Laboratory. The existing HPIL facility provides portable health physics monitoring instrumentation and direct reading dosimetry procurement, maintenance and calibration of radiation detection instruments, and research and development support-services to the INEL and others. However, the existing facility was not originally designed for laboratory activities and does not provide an ...
1995-05-01
Nuclear magnetic resonance on oriented XVTa and XXTa
Energy Technology Data Exchange (ETDEWEB)
XVTa and XXTa nuclei were oriented at low temperature as dilute impurities in Fe. The magnetic hyperfine splitting frequencies = B sub(HF)/Ih of the XVTa and XXTa ground states have been measured to be 320.45(11) and 317.552(55) MHz by using the technique of NMR-ON. Taking the known hyperfine field of Y Ta in Fe, the magnetic moments have been deduced: ( XVTa, 7/2 ) =2.270(45) and ( XXTa, 7/2 ) =2.250(45) sub(N). These values of the magnetic moments are discussed in the framework of the rotational model.
1984-08-01
Energy Technology Data Exchange (ETDEWEB)
This Reference Book contains a current copy of the Clean Water Act (Section 404) and the Rivers and Harbors Act (Sections 9 and 10) and those regulations that implement those sections of the statutes and appear to be most relevant to DOE activities. The document is provided to DOE and contractor staff for informational purposes only and should not be interpreted as legal guidance. Updates that include important new requirements will be provided periodically. Questions concerning this Reference Book may be directed to Mark Petts, IH-231 (FTS 896-2609 or Commercial 202/586-2609).
1992-03-01
Clean Water Act (Section 404) and Rivers and Harbors Act (Sections 9 and 10)
Energy Technology Data Exchange (ETDEWEB)
This Reference Book contains a current copy of the Clean Water Act (Section 404) and the Rivers and Harbors Act (Sections 9 and 10) and those regulations that implement those sections of the statutes and appear to be most relevant to DOE activities. The document is provided to DOE and contractor staff for informational purposes only and should not be interpreted as legal guidance. Updates that include important new requirements will be provided periodically. Questions concerning this Reference Book may be directed to Mark Petts, IH-231 (FTS 896-2609 or Commercial 202/586-2609).
1992-03-01
Energy Technology Data Exchange (ETDEWEB)
The INTEGRAL/SPI spectrometer was designed to observe the sky in the energy band of 20 keV to 8 MeV. The specificity of instrument SPI rests on the excellent spectral resolution (2.3 keV with 1 MeV) of its detecting plan, composed of 19 cooled germanium crystals; covering an effective area of 508 cm{sup 2}. The use of a coded mask, located at 1.7 m above the detection plan ensures to it a resolving power of 2.5 degrees. The aim of this thesis, begun before the INTEGRAL launch, is made up of two parts. The first part relates to the analysis of the spectrometer calibration data. The objective was to measure and check the performances of the telescope, in particular to validate simulations of the INTEGRAL/SPI instrument response. This objective was successfully achieved. This analysis also highlights the presence of a significant instrumental background noise. Whereas, the second part ...
2005-01-15
Improved eddy-current inspection for steam generator tubing
Energy Technology Data Exchange (ETDEWEB)
Computer programs have been written to allow the analysis of different types of eddy-current probes and their performance under different steam generator test conditions. The probe types include the differential bobbin probe, the absolute bobbin probe, the pancake probe and the reflection probe. The generator test conditions include tube supports, copper deposits, magnetite deposits, denting, wastage, pitting, cracking and IGA. These studies are based mostly on computed values, with the limited number of test specimens available used to verify the computed results. The instrument readings were computed for a complete matrix of the different test conditions, and then the test conditions determined as a function of the readings by a least-squares technique. A comparison was made of the errors in fit and instrument drift for the different probe types. The computations of the change in instrument reading ...
1989-01-01
To illustrate the implementation of a bottom-up approach to the study of culture in health disparities, this article describes the development of a cultural cancer screening scale (CCSS) using mixed methodologies. The aim was to identify cultural factors relevant to breast and cervical cancer screening, develop an instrument to assess them and examine its preliminary psychometric properties among Latin American (Latino) and non-Latino White (Anglo) women in Southern California. Seventy-eight Latino and Anglo women participated in semi-structured interviews, which were content coded based on Triandis' methods for the analysis of subjective culture. Based on the emerging cultural elements, items relevant to cancer screening were developed and pilot tested with 161 participants. After the instrument was refined, 314 Latino and Anglo women from various socioeconomic backgrounds completed the CCSS and data were factor analyzed ...
2010-09-23
Energy Technology Data Exchange (ETDEWEB)
Leafy samples often used as medicine in the Indian Ayurvedic system and vegetables were analyzed for 20 elements (As, Ba, Br, Ca, Ce, Cr, Cs, Co, Eu, Fe, K, La, Na, Rb, Sb, Sc, Sm, Sr, Th, Zn) by employing Instrumental Neutron Activation Analysis (INAA). The samples were irradiated at the 100 kW TRIGA-MAINZ nuclear reactor and the induced activities were counted by gamma ray spectrometry using an efficiency calibrated high resolution High Purity Germanium (HPGe) detector. The concentration of the elements in the medicinal and vegetable leaves and their biological effects on human beings are discussed.
1999-05-01
Energy Technology Data Exchange (ETDEWEB)
Specific parts of several plants (fruits, leaves, stem, bark and roots) often used as medicines in the Indian Ayurvedic system have been analysed for 20 elements (As, Ba, Br, Ca, Cl, Co, Cr, Cu, Fe, K, Mn, Mo, Na, P, Rb, Sb, Sc, Se, Sr and Zn) by employing instrumental neutron activation analysis (INAA). The samples were irradiated with thermal neutrons in a nuclear reactor and the induced activity was counted using high resolution gamma ray spectrometry. Most of the medicinal herbs have been found to be rich in one or more of the elements under study. (Author).
1997-01-01
Titanium Alloys for Medical Instrumentation
International Science & Technology Center (ISTC)
The New Titanium Alloys With Increased Mechanical Properties and Corrosion Resistance for Medical Instruments and their Coatings
Radionuclide X-ray fluorescence analysis with environmental application
International Nuclear Information System (INIS)
The purpose of this work is to present a comprehensive, instructive analysis of the basis of radionuclide XRFA, to describe methods of sample preparation for environmental analysis and to make the reader more familiar with the procedures, methods and instrumentation of radionuclide XRFA used in this field. This book discusses the use of radionuclide XRFA for solving analytical problems of the environment and information is presented concerning the current state of research and use of radionuclide XRFA in this significant area. The present volume will serve as a basic source of data and also as a laboratory handbook. refs.; figs.; tabs.
1990-01-01
Improved eddy-current inspection for steam generator tubing
International Nuclear Information System (INIS)
Computer programs have been written to allow the analysis of different types of eddy-current probes and their performance under different steam generators test conditions. The probe types include the differential bobbin probe, the absolute bobbin probe, the pancake probe and the reflection probe. The generator test conditions include tube supports, copper deposits, magnetite deposits, denting, wastage, pitting, cracking, and intergranular attack. These studies are based mostly on computed values, with the limited number of test specimens available used to verify the computed results. The instrument readings were computed for a complete matrix of the different test conditions, and then the test conditions determined as a function of the readings by a least-squares technique. A comparison was made of the errors in fit and instrument drift for the different probe types. The computations of the change in ...
1990-03-01
Abstract Background: Aution Max AX-4030, a test strip analyzer recently introduced to the market, represents an upgrade of the Aution Max AX-4280 widely employed for urinalysis. This new instrument model can allocate two different test strips at the same time. In the present study the two instruments have been compared together with the usage of Uriflet 9UB and the recently produced Aution Sticks 10PA urine strips, the latter presenting an additional test area for the measurement of urinary creatinine. Methods: Imprecision and correlation between instruments and strips have been evaluated for chemical-physical parameters. Accuracy was evaluated for protein, glucose and creatinine by comparing the semi-quantitative results to those obtained by quantitative methods. The well-known interference effect of high ascorbic acid levels on urine glucose test strip determination was evaluated, ascorbic acid influence was also ...
2011-09-26
Economic policy instruments for the control of air pollution in Poland
International Nuclear Information System (INIS)
The World Bank is analyzing the role of economic policy instruments for the control of air pollution in Poland, in cooperation with Polish and international experts. The first stage, covering Poland as a whole, was recently completed, jointly financed with the U.S. E.P.A. and the Government of the Netherlands. The second stage, now under way, will extend the analysis into a specific regional framework. Stage 2 is financed by the World Bank, the Polish Government, and the U.K. Environment Know-How Fund. Air Pollution in Poland is overwhelmingly caused by energy production and uses, due to the fact that the Polish economy depends heavily on coal and lignite. At present, vehicles contribute less to total emissions than do coal burning and industrial processes, although they account for 25-35% of nitrogen oxides, carbon monoxide, hydrocarbons and lead; and the concentrated in areas of high population density. The paper shows how economic, technical ...
1993-06-13
System 80+{trademark} Standard Design: CESSAR design certification. Volume 8: Amendment I
Energy Technology Data Exchange (ETDEWEB)
This report, entitled Combustion Engineering Standard Safety Analysis Report -- Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These volumes describe the Combustion Engineering, Inc. System 80{sup +}{trademark} Standard Design. This volume 8 provides a description of instrumentation and controls.
1990-12-21
Standard deviation of measurement results in x-ray fluorescence spectrometry
International Nuclear Information System (INIS)
The standard deviation of measurement results of a given element in XRF spectrometry depends on three factors: concentration and concentration region, atomic number and matrix. The effects of these factors were investigated by an XRF instrument type ARL 72.000 for aluminium metal, bauxite-red mud and aluminium using computerized data processing. A comparison of linear and nonlinear relation between concentration and the result of XRF analysis was made for the determination of standard deviation. (R.P.).
1984-11-13
Economic effects on taxing CO{sub 2} emissions
Energy Technology Data Exchange (ETDEWEB)
The CO{sub 2} emissions can be reduced by using economic instruments, like carbon tax. This project included two specific questions related to CO{sub 2} taxation. First one was the economic effects of increasing CO{sub 2} tax and decreasing other taxes. Second was the economic adjustment costs of reducing net emissions instead of gross emissions. A computable general equilibrium (CGE) model was used in this analysis. The study was taken place in Helsinki School of Economics
1996-12-31
Comparative study on tea chemical analysis; Estudo comparativo na analise quimica de chas
Energy Technology Data Exchange (ETDEWEB)
This paper describes the application of the instrumental analytical methods: neutron activation techniques, atomic absorption spectroscopy and flame emission spectroscopy, used to analyse some home-made teas, determining Na, K and Cl and comparing the results. This study verify whether the home-made teas used for rehydration of the children reach the composition recommended by WHO (World Health Organization). (author). 6 refs., 6 tabs.
1995-12-31
Energy Technology Data Exchange (ETDEWEB)
The detectors used in the TS93 balloon flight produced a large volume of information for each cosmic ray trigger. Some of the data was visual in nature, other portions contained energy deposition and timing information. The data sets are amenable to conventional analysis techniques but there is no assurance that conventional techniques make full use of subtle correlations and relations amongst the detector responses. With the advent of neural network technologies, particularly adept at classification of complex phenomena, it would seem appropriate to explore the utility of neural network techniques to classify particles observed with the instruments. In this paper neural network based methodology for signal/background discrimination in a cosmic ray space experiment is discussed. Results are presented for electron and positron classification in the TS93 flight data set and will be compared to conventional analyses.
1995-09-01
International Nuclear Information System (INIS)
An instrumental neutron activation technique of determining molybdenum in ores is based on measuring gamma-activity of the "9"9Mo isotope with the use of planar and coaxial semiconductor spectrometers. A lot consisting of 50 portions, 0.5 g each, is being irradiated for 10 hours by a flow of neutrons with the density of 10"1"2 n/cm"2xsec. On the lot being allowed to stay for 3-4 days, its activity is measured during 1-5 minutes. Monoethalons based upon phenol-formaldehyde resin are used as standards. The sensitivity of the technique is 10"-"4%, reproducibility error being not higher than 10%, efficiency up to 50 portions for a working shift.
Wet limestone FGD solids analysis by thermogravimetry
Energy Technology Data Exchange (ETDEWEB)
Wet limestone scrubbing is once again becoming a popular technology for removal of sulfur dioxide (SO{sub 2}) from power plant emissions. Critical to the operation of wet limestone flue gas desulfurization (FGD) systems is accurate chemical analysis of scrubber solids. The analytical technique of thermogravimetry is ideal for this application, as the instrument can give precise readings of the principal scrubber solids components, calcium sulfite/sulfate hemihydrate, calcium sulfate dihydrate (gypsum), and unused calcium carbonate. The data provides plant chemists, engineers, and operators with information needed to fine-tune scrubber operation and detect process upsets. (orig.)
2004-07-01
Versatile charged particle activation technique for the analysis of the noble metals
Energy Technology Data Exchange (ETDEWEB)
The general usefulness of neutron activation analysis (NAA) for samples containing the platinum group elements (PGE) and Au, either as major or trace constituents, is discussed. Charged particle activation is shown to be a viable or complementary alternative. Proton (6-10 MeV) and alpha particle (9-15 MeV) beams, produced in a tandem Van de Graaff accelerator, have been established to be the most effective choice. By taking advantage of the Coulomb barrier effect and the fact that many charged particle induced reactions have relatively large threshold values, the same instrumental technique can be applied, with minor modifications, to a wide range of materials.
1982-01-01
Versatile charged particle activation technique for the analysis of the noble metals
Energy Technology Data Exchange (ETDEWEB)
The general usefulness of neutron activation analysis (NAA) for samples containing the platinum group elements and Au, either as major or trace constituents, is discussed. Charged particle activation is shown to be a viable or complementary alternative. Proton (6-10 MeV) and alpha particle (9-15 MeV) beams, produced in a Tandem van de Graaff accelerator, have been established to be the most effective choice. By taking advantage of the Coulomb barrier effect and the fact that many charged particle induced reactions have relatively large threshold values, the same instrumental technique can be applied, with minor modifications, to a wide range of materials.
1983-01-01
Energy Technology Data Exchange (ETDEWEB)
This study of the inorganic chemical composition of 10 different Nigerian medicinal plant species, using the technique of instrumental neutron activation analysis (INAA), resulted in the determination of the concentrations of 18 major, minor, and trace elements: Al, Ba, Br, Ca, Cl, Eu, Fe, Ga, K, La, Mn, Na, Sb, Sc, Si, Sm, V, and Zn. The parts of the plants used were roots, leaves, and bark. The NBS SRM 1571 Orchard Leaves was also analyzed to assess the accuracy of the procedures used. 21 refs., 4 tables.
1984-04-02
Energy Technology Data Exchange (ETDEWEB)
DOE/NNSA and IRSN collaborated on a study of gamma-ray instruments and analysis methods used to perform isotopic measurements of special nuclear materials. The two agencies agreed to collaborate on the project in response to inconsistencies that were found in the various versions of software and hardware used to determine the isotopic abundances of uranium and plutonium. IRSN used software developed internally to test the MGA and FRAM isotopic analysis codes for criteria used to stop data acquisition. The stop-criterion test revealed several unusual behaviors in both the MGA and FRAM software codes.
2009-01-01
In field nuclear forensics: An overview of applicable instrumentation
International Nuclear Information System (INIS)
Recent seizures of nuclear materials, and particularly of fissionable nuclear materials, have resulted in an increased awareness of the need for fieldable instrumentation for the detection and characterization of suspect packages and materials. The ability to perform in-field assessments of materials contained in suspect packages is important for several reasons. First, and most importantly, determination of the type and quantity of material provides information critical to personnel safety. The personnel at potential risk may include both the general population in the area of the package and incident response personnel. Additionally, it would be advantageous to gain information that could result in attribution of the suspect package to a particular facility or pathway as soon as possible after interception. Limited access to a suspect package could also require the use of fieldable characterization instrumentation as opposed to transporting ...
1997-06-12
Instrumentation for Materials Research - Major Instrumentation Projects
... Materials Research - Major Instrumentation Project (IMR-MIP) program in the Division of Materials ... for materials preparation and characterization essential for researchers studying materials in a ...
Aanderaa Data Instruments AS Profile on Environmental Expert
...on Environmental Expert Aanderaa Data Instruments develops, manufactures and markets oceanographic and meteorological instruments and special systems for collecting environmental data. Data can be ...
Nuclear magnetic resonance on oriented "1"7"5Ta and "1"7"7Ta
International Nuclear Information System (INIS)
"1"7"5Ta and "1"7"7Ta nuclei were oriented at low temperature as dilute impurities in Fe. The magnetic hyperfine splitting frequencies #nu#="+#mu#B sub(HF)/Ih"+ of the "1"7"5Ta and "1"7"7Ta ground states have been measured to be 320.45(11) and 317.552(55) MHz by using the technique of NMR-ON. Taking the known hyperfine field of "1"8"1Ta in Fe, the magneticmoments have been deduced: "+#mu#("1"7"5Ta, 7/2"+)"+=2.270(45) and "+#mu#("1"7"7Ta, 7/2"+)"+=2.250(45)#mu# sub(N). These values of the magnetic moments are discussed in the framework of the rotational model. (author).
Microprocessor-controlled anodic stripping voltammeter for trace metal analysis in tap water
Energy Technology Data Exchange (ETDEWEB)
The construction and use of a portable, microprocessor controlled anodic stripping voltameter for on-site simultaneous metal analysis of copper, lead and cadmium in tap water is discussed. The instrumental system is comprised of a programmable controller which permits keying in analytical parameters such as sparge time and plating time: a rotating cell for efficient oxygen removal and amalgam formation; and, data handling via a minicomputer or analog pen recorder. Plating and stripping potentials are controlled by a digital potentiostat; stripping is done using a staircase waveform with measurement of the current after a one msec delay. In this way charging current effects are minimized. Results of tap water analysis showed 3 +- 1 ..mu..g/L lead, 22 +- 0.3 ..mu..g/L copper, and less than 0.2 ..mu..g/L cadmium for a Berkeley, California tap water, and 1-1000 ..mu..g/L Cu, 1 -2 ..mu..g/L Pb for ten samples of Seattle, ...
1984-06-01
Vibration signature analysis of AFM images
Energy Technology Data Exchange (ETDEWEB)
Vibration signature analysis has been commonly used for the machine condition monitoring and the control of errors. However, it has been rarely employed for the analysis of the precision instruments such as an atomic force microscope (AFM). In this work, an AFM was used to collect vibration data from a sample positioning stage under different suspension and support conditions. Certain structural characteristics of the sample positioning stage show up as a result of the vibration signature analysis of the surface height images measured using an AFM. It is important to understand these vibration characteristics in order to reduce vibrational uncertainty, improve the damping and structural design, and to eliminate the imaging imperfections. The choice of method applied for vibration analysis may affect the results. Two methods, the data dependent systems (DDS) ...
1995-12-31
Scientific Data Management in the Coming Decade
This is a thought piece on data-intensive science requirements for databases and science centers. It argues that peta-scale datasets will be housed by science centers that provide substantial storage and processing for scientists who access the data via smart notebooks. Next-generation science instruments and simulations will generate these peta-scale datasets. The need to publish and share data and the need for generic analysis and visualization tools will finally create a convergence on common metadata standards. Database systems will be judged by their support of these metadata standards and by their ability to manage and access peta-scale datasets. The procedural stream-of-bytes-file-centric approach to data analysis is both too cumbersome and too serial for such large datasets. Non-procedural query and analysis of schematized self-describing data is both easier to use and allows much more ...
2005-01-01
State of the Art Laser Induced Breakdown Spectroscopy
International Nuclear Information System (INIS)
Methods currently being used or developed for the elemental analysis of materials are chemical analysis, non-destructive inspection and calorimetry. The chemical analysis, which removes high-level radioactive elements through chemical treatments and then performs the quantitative analysis using the ICP-MS(Inductively Coupled Plasma - Mass Spectrometer) or the ID-MS(Isotope Dilution Mass Spectrometer), is recognized the most accurate. However, it requires a long, complex pre-treatment process in which a mass spectrometer could be contaminated. To solve this problem, a new method, which can be performed with high-level radioactivity and at high temperature, was desired. Such a method should also have the same accuracy as the chemical analysis, with a less possibility for instruments to be contaminated. In addition, as interests in the environment and the life ...
Energy Technology Data Exchange (ETDEWEB)
A study conducted at the IHS had the aim to obtain basic information on whether it is possible to build flow turbines following the free jet principle that are on a par with, or superior to, the conventional design, especially in terms of performance and the efficiency curve. Several inflow contours with a ventilated free jet and a conventional flow turbine were studied. The direct comparison of these variants revealed a slightly enhanced peak load efficiency and a very distinct superiority of the free jet contour during partial load. But the efficiency of all variants failed to attain the values claimed by commercial manufacturers. As compared to the initial contour, peak load efficiency was enhanced by 5 per cent. During partial load, the variants studied showed a distinct superiority of the free jet concept over the contour of conventional flow turbines. (orig.) [Deutsch] Am IHS wurde eine Untersuchung mit dem Ziel durchgefuehrt, ...
1997-12-31
A study examined the concept of interpersonal communication competence in order to construct a more refined instrument than those currently used to measure competence. Using 70 items drawn from several existing measures of competence, 660 volunteer subjects from undergraduate communication courses at a large midwestern university provided their conception of adept and inept communicators, defined respectively as the best and worst communicators they know. Direct and multiple step-wise discriminant analyses were performed to determine the extent to which these items best discriminated between subjects' conceptions of adept and inept communicators, and to determine which of the 70 items best discriminated between these conceptions. Canonical discriminant functions revealed that the subjects clearly distinguished between adept and inept communicators. Classification results revealed that nearly 97% of the cases were classified correctly. Results of the multiple ...
1989-05-01
Nuclear Reactor Sharing Program
Energy Technology Data Exchange (ETDEWEB)
The Ohio State University Research Reactor (OSURR) is licensed to operate at a maximum power level of 500 kW. A pool-type reactor using flat-plate, low enriched fuel elements, the OSURR provides several experimental facilities including two 6-inch i.d. beam ports, a graphite thermal column, several graphite-isotope-irradiation elements, a pneumatic transfer system (Rabbit), various dry tubes, and a Central Irradiation Facility (CIF). The core arrangement and accessibility facilitates research programs involving material activation or core parameter studies. The OSURR control room is large enough to accommodate laboratory groups which can use control instrumentation for monitoring of experiments. The control instrumentation is relatively simple, without a large amount of duplication. This facilitates opportunities for hands-on experience in reactor operation by nuclear engineering students making reactor parameter measurements. For neutron ...
1994-09-01
Advanced nanoscale separations and mass spectrometry for sensitive high-throughput proteomics
Energy Technology Data Exchange (ETDEWEB)
We review recent development in separations and mass spectrometric instrumentation for sensitive and high-throughput proteomic analyses. These efforts have been primarily focused on the development of high-efficiency (separation peak capacity of ~103) nanoscale liquid chromatography (nanoLC; e.g., flow rates extending down to ~20 nL/min at optimal separation linear velocities through narrow packed capillaries) in combination with advanced mass spectrometry (MS), including high sensitivity and high resolution Fourier transform ion cyclotron resonance (FTICR) MS. This technology enables MS analysis of low nanogram-level proteomic samples (i.e., nanoscale proteomics) with individual protein identification sensitivity at the low zeptomole-level. The resultant protein measurement dynamic range can reach 106 for nanogram-sized proteomic samples, while more abundant proteins can be detected from complex sub-picogram size proteome samples. The average ...
2005-06-01
The use of x-ray fluorescence in the detection of inorganic elements in medicines drugs
International Nuclear Information System (INIS)
Based on the instrumental wavelength dispersive X-ray fluorescence technique of analysis (W D-X R F), the inorganic elements in four samples of commercial medicines drugs were analyzed. The samples were used without any chemical separation of the elements or chemical pre-treatment. Eleven elements could be identified, namely Si, P, S, Cl, K, Ca, Ti, Mn, Fe, Cu and Zn. However, Si, Ti and Mn have not been mentioned in the printed instructions for the use of the medicines drugs by the producers. (author)
Synthesis and characterization of Rosebengal/folicacid-functionalized multiwall carbon nanotubes
British Library Electronic Table of Contents (United Kingdom)
Multiwall carbon nanotubes (MWCNTs) were functionalized with a photosensitizer, rosebengal (RB), and folicacid (FA), an anti-cancer drug simultaneously and individually, which was characterized with various analytical instruments like Fourier Transform Iinfrared (FTIR) spectroscopy, UV?Vis spectroscopy, Thermogravimetric analysis (TGA), Photoluminescence (PL) spectroscopy, X-ray photoelectron spectroscopy (XPS), and Transmission electron microscopy (TEM). FTIR spectra confirmed the chemical modification of MWCNT. The chemical functionalization of MWCNT with RB was further supported by UV?Vis and PL spectra.
2011-01-01
International Nuclear Information System (INIS)
The symposium covers papers under different sections namely, (i) Core physics and Fuel management, (ii) Commissioning of facilities and systems, (iii) Operational experience and Human resource development, (iv) Fuel handling, Maintenance management and Surveillance, (v) Instrumentation and Control and Power supply systems, (vi) Analysis, modifications and developments for enhancing operational safety, (vii) Chemistry control and Effluent management, (viii) Radiation and industrial safety and (ix) Steam generators, Turbo-generators and other auxiliaries. Papers relevant to INIS are indexed separately. (author)
2006-11-13
Pressure drop and heat transfer in gas-cooled rod bundles
International Nuclear Information System (INIS)
Extensive experimental and analytical investigations of fluid flow and heat transfer in gas-cooled rod bundles have been carried out. Different bundle geometries with partially or fully roughened rod surfaces were tested in a carbon dioxide loop. An advanced and comprehensive measuring control and instrumentation are important design features of this experiment. Comprehensive thermal hydraulic subchannel analysis computer codes have been developed in order to assist fuel element design calculation for gas-cooled reactors. The experiments, codes and their verification procedure are described and the results of comparisons between measured and calculated pressure and temperature distributions are given. (orig.).
Energy Technology Data Exchange (ETDEWEB)
The recent definition of a postulated thermal shock accident followed promptly by system repressurization, termed an overcooling or pressurized thermal shock accident, has set a large analysis and research effort into motion. The essential elements are concerned with defining the accident transients, evaluating the instrumentation and controls that cause the postulated accidents, and evaluating the metallurgical and structural mechanics aspects of the reactor vessel with respect to its failure potential. This paper poses the question faced by the Nuclear Regulatory Commission (NRC) for the vessel steel embrittlement, annealing, and surveillance dosimetry facets of this postulated accident and provides information on our plans for study of this problem as well as current status.
1981-10-01
British Library Electronic Table of Contents (United Kingdom)
We operate a new NEC 250kV single-stage accelerator mass spectrometer (SSAMS) next to our established 5MV tandem. This permits good comparison of 14C-AMS and challenges SSAMS performance. Initial SSAMS ion-optical deficiencies have been addressed by shimming the injection magnet and 3permil 14C/13C measurement with background limited by sample chemistry is routine. Higher-precision analysis is also achievable. A problematic measurement interference remains, however. The small spectrometer was procured to add measurement capacity, and for experiments with positive ions, but is now the preferred instrument for both convenience and measurement quality.
2010-01-01
Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposed
British Library Electronic Table of Contents (United Kingdom)
Objective: Results of reliability and agreement studies are intended to provide information about the amount of error inherent in any diagnosis, score, or measurement. The level of reliability and agreement among users of scales, instruments, or classifications is widely unknown. Therefore, there is a need for rigorously conducted interrater and intrarater reliability and agreement studies. Information about sample selection, study design, and statistical analysis is often incomplete. Because of inadequate reporting, interpretation and synthesis of study results are often difficult. Widely accepted criteria, standards, or guidelines for reporting reliability and agreement in the health care and medical field are lacking. The objective was to develop guidelines for reporting reliability and...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Progress reports on the European Research Centre for Air Pollution Control Measures project are presented. Topics covered were: assessment and analysis of the impacts of airborne pollutants on forest trees, and distinction from other potential causes of recent forest dieback; research into atmospheric dispersion, conversion and deposition of airborne pollutants; development and optimization of industrial technical processes to reduce or avoid emissions; and providing instruments and making recommendations to the industrial and political sectors.
1985-01-01
International Nuclear Information System (INIS)
Instrumental neutron activation analysis is used for simultaneously determination of macrocomponents in ferroelectric materials LLZT. Pb, Zr, Ti have been determined by "2"0"3Pb, "8"9Zr and "4"8Sc nuclides created by fast neutron (14.5 MeV) activation. Application of paraffine as neutron moderator and reflector allows to simultaneously determine lanthanum by "1"4"0La nuclide. It has been shown that zirconium, titanium and lanthanum can be determined with the accuracy of #+-#0.1 mas. % and lead - #+-#0.7 mas. %.
Energy Technology Data Exchange (ETDEWEB)
Laser-Induced Breakdown Spectroscopy was selected by NASA as part of the ChemCam instrument package for the Mars Science Laboratory rover to be launched in 2009. ChemCam's Laser-Induced Breakdown Spectroscopy instrument will ablate surface coatings from materials and measure the elemental composition of underlying rocks and soils at distances from 1 up to 10 m. The purpose of our studies is to develop an analytical methodology enabling identification and quantitative analysis of these geological materials in the context of the ChemCam's Laser-Induced Breakdown Spectroscopy instrument performance. The study presented here focuses on several terrestrial rock samples which were analyzed by Laser-Induced Breakdown Spectroscopy at an intermediate stand-off distance (3 m) and in an atmosphere similar to the Martian one (9 mbar CO{sub 2}). The experimental results highlight the matrix effects ...
2006-03-15
International Nuclear Information System (INIS)
Laser-Induced Breakdown Spectroscopy was selected by NASA as part of the ChemCam instrument package for the Mars Science Laboratory rover to be launched in 2009. ChemCam's Laser-Induced Breakdown Spectroscopy instrument will ablate surface coatings from materials and measure the elemental composition of underlying rocks and soils at distances from 1 up to 10 m. The purpose of our studies is to develop an analytical methodology enabling identification and quantitative analysis of these geological materials in the context of the ChemCam's Laser-Induced Breakdown Spectroscopy instrument performance. The study presented here focuses on several terrestrial rock samples which were analyzed by Laser-Induced Breakdown Spectroscopy at an intermediate stand-off distance (3 m) and in an atmosphere similar to the Martian one (9 mbar CO2). The experimental results highlight the matrix effects and the measurement ...
2006-03-01
The SUERC AMS laboratory after 3 years
British Library Electronic Table of Contents (United Kingdom)
The new SUERC AMS Laboratory was described at AMS-9. Since then there have been technological developments, added and improved analysis capability, the formation of additional complementary groups, the purchase of another instrument, and many samples measured. Be, C, Al, Cl, Ca and I-AMS are established with measured species changing weekly. Full-terminal potential running is now routine and 5MV is proving sufficient for all species. Ion detection and evaluation has also been improved by the use of even thinner detector windows as necessary and a more powerful on-line data analysis system. Routine radiocarbon measurement is to 4permil reproducibility at middling current and graphite samples of as little as 100mg C can be accommodated. Even smaller samples can be measured as CO2 using He ca...
2007-01-01
Scientific report 1997; Rapport scientifique 1997
Energy Technology Data Exchange (ETDEWEB)
In this book are found technical and scientific papers on the main works of the Direction of the Fuel Cycle (DCC) in France. The study fields are: the up-side of the nuclear fuel cycle with theoretical studies (plasma simulation) and technological developments and instrumentation (lasers diodes, carbides plasma projection, carbon 13 enrichment); the down-side nuclear fuel cycle with theoretical studies (ion Eu{sup 3+} complexation simulation, decay simulation, uranium and plutonium diffusion study, electrolyser operating simulation), scenario studies ( recycling, wastes management), experimental studies; dismantling and cleaning (soils cleaning, surface-active agent for decontamination, fault tree analysis); analysis with expert systems and mass spectrometry. (A.L.B.)
1998-07-01
Offshore platforms and pipelines
Energy Technology Data Exchange (ETDEWEB)
This book discusses problems and topics important for the design and construction of fixed offshore platforms used for drilling and producing petroleum from beneath the sea. A general description of offshore platforms serves as an introduction to the whole problem of offshore structures. A chapter on the hydrodynamic analysis of fixed offshore platforms gives the basis for the layout and construction of such structures. A guide to soil investigation methods essential for the geotechnical analysis of foundation designs for all types of offshore structures concentrates on the instrumentation equipment actually used. Detailed information is given on pile foundations with special emphasis on steel jacket platforms. The behaviour of gravity platforms during the final construction stage is analysed. The basis for the design of subsea pipelines and their stability is treated as well as the scour protection near offshore platforms.
1986-01-01
Nuclear analytical techniques in Cuban sugar industry
Energy Technology Data Exchange (ETDEWEB)
This paper is a review concerning the application of Nuclear Analytical Techniques in the Cuban sugar industry. The most complete elemental composition of final molasses (34 elements) and natural zeolites (38) this last one employed as an auxiliary agent in sugar technological processe4s has been performed by means of instrumental Neutron Activation Analysis (INAA) and X-Ray Fluorescence Analysis (XRFA). The trace elemental sugar cane soill-plant relationship and elemental composition of different types of Cuban sugar (raw, blanco-directo and refine) were also studied. As a result, valuable information referred to the possibilities of using these products in animal and human foodstuff so as in the other applications are given. (author). 34 refs., 6 figs., 1 tab.
1997-12-01
Kolmogoroff constants at the 1976 ITCE
Energy Technology Data Exchange (ETDEWEB)
The high-frequency data from 12 sensors at the ITCE 1976 are analyzed to determine the Kolmogoroff constants for velocity, temperature and humidity fluctuations, ..cap alpha../sub u/, ..cap alpha../sub T/, and ..cap alpha../sub q/. The occurrence of aliasing in the spectral analysis in some cases together with the limited response of some sensors at the higher frequencies introduces some uncertainties into the analysis. The Soviet sonic anemometer, fine-wire thermometer and infrared hygrometer and the Australian infrared hygrometer provide the best information, namely that: ..cap alpha../sub u/ = 0.59 +/- 0.01, ..cap alpha../sub T/ = 0.68 +/- 0.02, ..cap alpha../sub q/ = 0.76 +/- 0.03, where the errors quoted refer solely to statistical errors. The other instruments provide general support to these values. The technique of using spectral density measurements to determine eddy fluxes is illustrated.
1982-01-01
Theoretical and experimental research efforts in evaluating an innovative concept for vertical axis wind turbines (VAWT) are described. The concept is that of using straight blades composed of circulation controlled airfoil sections. The theoretical analysis has been developed to determine the unsteady lift and moment characteristics of multiple-blade cross-flow wind turbines. To determine the drag data needed as input to the theoretical analysis, an outdoor test model VAWT has been constructed; design details, instrumentation, and calibration results are reported. Initial testing is with fixed pitch blades having cross-sections of conventional symmetrical airfoils. Costs of building the test model are included, as well as estimates for blades constructed with composite materials. These costs are compared with those of other types of wind turbines.
1978-10-01
Dimensions and Latent Classes of Episodic Mania-Like Symptoms in Youth: An Empirical Enquiry
British Library Electronic Table of Contents (United Kingdom)
The dramatic increase in diagnostic rates of bipolar disorder in children and adolescents in the USA has led to an intense interest in the phenomenology of the disorder. Here we present data from a newly-developed instrument to assess episodic mania-like symptoms in youth in a large population-based sample (N?=?5326) using parent- and self-report. We found that a substantial proportion of children screened positive for having episodes of ?going high? and were at an increased risk for morbidity and impairment. Using factor analysis, we identified that episodic mania-like symptoms comprised two dimensions: An under-controlled dimension that was associated with significant impairment, and a low-risk exuberant dimension. Using latent class analysis, we identified a small group of children scor...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Medicinal plants are available in the markets in Belo Horizonte, Minas Gerais. The objective of this work is to investigate the Ca, Cr, Cu, Fe, K, Mg, Na e Zn concentrations in two lots of usually known diuretics plants (azeitona do mato, cabelo de milho, cavalinha, cervejinha do campo, chapeu de couro, congonha de bugre, marmelinho do campo and quebra pedra) bought with an interval of time - six months - between the purchases. The elemental concentrations were determined applying k{sub 0} instrumental neutron activation analysis and atomic absorption spectrophotometry analysis. (author)
2002-07-01
International Nuclear Information System (INIS)
This paperwork explain the method of water sampling to obtain the precipitate of BaCO3 solutions that will be used to analyze 13C from field work in Kelana Jaya, Selangor, Langkawi, Kedah and Taiping, Perak. The sampling involves collecting of water samples for groundwater from boreholes and surface water from canal, river, pond and ex-mining pond from several locations at the study sites. This study also elaborates the instruments and chemicals used. The main purpose of this sampling is to obtain the precipitate of BaCO3 for 13C analysis of dissolved inorganic carbon (DIC). A correct sampling method according to standard is very important to ensure an accurate and precise result. With this, the data from the laboratory analysis result can be fully utilized to make the interpretation of the pollutants movement. (Author)
2009-10-06
International Nuclear Information System (INIS)
The problems are discussed of using radionuclide X-ray fluorescence analysis (the most frequently used source is "2"4"1Am) and neutron activation analysis for monitoring the chemical quality of the working environment of a welder. Elements determinable by these methods are listed and the advantages of the methods stated with regard to speed, simplicity and appropriate accuracy of measurement together with commercial availability of the instruments. Welding as a source of harmful substances is assessed by determination of the amount of chromium in aerosols generated by welding austenitic chromium-nickel steels. The described methods allow to obtain a complex image of the chemical nature of welding aerosols and to understand the mechanism of their impact on the human organism. (J.C.).
1986-01-01
Radioanalytical methods of rare earth element determination
International Nuclear Information System (INIS)
Instrumental neutron activation analysis (INAA) and radionuclide X-ray fluorescence analysis (RXFA) were used for the determination of rare earth elements. For INAA, solution obtained by sample decomposition was dripped onto filter paper, enclosed and sealed into a polyethylene foil. The sample was activated in reactor WWR-S over a period of 4 to 6 hours with a neutron fluence of 10"1"3cm"-"2. Gamma radiation measurement was carried out with a planar and a coaxial HP-Ge detector in three decay periods. La, Ce, Nd, Sm, Eu, Gd, Tb, Ho, Tm, Yb and Lu were determined. The advantage of the method is its accuracy and high sensitivity, the disadvantage is the time-consuming analysis. The RXFA method was used as a rapid and operative method for the analysis of loose ore samples, aqueous and organic solutions of rare earth elements. For exciting X-ray radiation, "2"4"1Am was used and the ...
1989-06-01
The NIR Upgrade to the SALT Robert Stobie Spectrograph
The near infrared (NIR) upgrade to the Robert Stobie Spectrograph (RSS) on the Southern African Large Telescope (SALT), RSS/NIR, extends the spectral coverage of all modes of the visible arm. The RSS/NIR is a low to medium resolution spectrograph with broadband imaging, spectropolarimetric, and Fabry-Perot imaging capabilities. The visible and NIR arms can be used simultaneously to extend spectral coverage from approximately 3200 A to 1.6 um. Both arms utilize high efficiency volume phase holographic gratings via articulating gratings and cameras. The NIR camera is designed around a 2048x2048 HAWAII-2RG detector housed in a cryogenic dewar. The Epps optical design of the camera consists of 6 spherical elements, providing sub-pixel rms image sizes of 7.5 +/- 1.0 um over all wavelengths and field angles. The exact long wavelength cutoff is yet to be determined in a detailed thermal analysis and will depend on the semi-warm instrument cooling ...
2006-01-01
Preparation of high burnup fuel post-irradiation testing facility
Energy Technology Data Exchange (ETDEWEB)
In the fuel testing facilities of Japan Atomic Energy Research Institute, the post-irradiation test of practical fuel used in nuclear power stations was begun in December, 1979, and the soundness of practical fuel has been confirmed, and the valuable post-irradiation test data on the behavior of fuel have been acquired. Recently, the heightening of fuel burnup has been advanced, and also in fuel testing facilities, the development and preparation of the post-irradiation testing facility required for examining in detail high burnup fuel have been carried out. The course of the installation of the post-irradiation testing facility and the outline of the facility are reported. As the preparation of the post-irradiation testing facility for high burnup fuel, a hyperfine hardness tester that measures dynamic hardness, the measuring instrument for pellet thermal diffusion rate by laser flash method, the measuring instrument for pellet melting point ...
1996-05-01
Performance of the upgraded LTP-II at the ALS Optical Metrology Laboratory
Energy Technology Data Exchange (ETDEWEB)
The next generation of synchrotrons and free electron laser facilities requires x-ray optical systems with extremely high performance, generally of diffraction limited quality. Fabrication and use of such optics requires adequate, highly accurate metrology and dedicated instrumentation. Previously, we suggested ways to improve the performance of the Long Trace Profiler (LTP), a slope measuring instrument widely used to characterize x-ray optics at long spatial wavelengths. The main way is use of a CCD detector and corresponding technique for calibration of photo-response non-uniformity [J. L. Kirschman, et al., Proceedings of SPIE 6704, 67040J (2007)]. The present work focuses on the performance and characteristics of the upgraded LTP-II at the ALS Optical Metrology Laboratory. This includes a review of the overall aspects of the design, control system, the movement and measurement regimes for the stage, and analysis of the ...
2008-07-14
Institutt for Energiteknikk - Annual Report 1994
Energy Technology Data Exchange (ETDEWEB)
Work at Institutt for energiteknikk (IFE) comprises both nuclear and non-nuclear activities. The main nuclear program is centered on the Halden Reactor Project. In 1958, the first Halden Reactor Project Agreement was signed by organisations representing 12 European countries. During 1994 France became a full member and associate membership was established with Russia. Accordingly, 16 countries were participating in the Project by the end of the year. The objectives have evolved from being simply a demonstration of the operation of a boiling heavy-water reactor to becoming a substantial research and development programme covering the domains of human-machine interaction, fuel behaviour, materials testing, water chemistry, and instrumentation. In 1994, significant progress was achieved in all of the areas addressed by the project, including the re-instrumentation of irradiated fuel rods, fission gas release, irradiation-assisted stress corrosion ...
1995-12-01
International Nuclear Information System (INIS)
Due to the failure of the instrument and control devices of nuclear power plants caused by aging, nuclear power plants occasionally trip. Even a trip of a single nuclear power plant (NPP) causes an extravagant economical loss and deteriorates public acceptance of nuclear power plants. Therefore, the replacement of the instrument and control devices with proper consideration of the aging effect is necessary in order to prevent the inadvertent trip. In this paper we investigated the optimal replacement periods of the control computer's components of Wolsung nuclear power plant Unit 1. We first derived mathematical models of optimal replacement periods to the digital control computer's components of Wolsung NPP Unit 1 and calculated the optimal replacement periods analytically. We compared the periods with the replacement periods currently used at Wolsung NPP Unit 1. The periods used at Wolsung is not based on mathematical ...
1993-01-01
An analysis of selected atmospheric icing events on test cables
Energy Technology Data Exchange (ETDEWEB)
In cold countries, the design of transmission lines and communication networks requires the knowledge of ice loads on conductors. Atmospheric icing is a stochastic phenomenon and therefore probabilistic design is used more and more for structure icing analysis. For strength and reliability assessments, a data base on atmospheric icing is needed to characterize the distributions of ice load and corresponding meteorological parameters. A test site where icing is frequent is used to obtain field data on atmospheric icing. This test site is located on the Mt. Valin, near Chicoutimi, Quebec, Canada. The experimental installation is mainly composed of various instrumented but non-energized test cables, meteorological instruments, a data acquisition system, and a video recorder. Several types of icing events can produce large ice accretions dangerous for land-based structures. They are rime due to in-cloud icing, glaze caused by ...
1996-12-01
Differential influence of instruments in nuclear core activity evaluation by data assimilation
International Nuclear Information System (INIS)
The global neutronic activity fields of a nuclear core can be reconstructed using data assimilation. Indeed, data assimilation allows to combine both measurements from instruments and information from a model, to evaluate the best possible neutronic activity within the core. We present and apply a specific procedure which evaluates the influence of measures by adding or removing instruments in a given measurement network (possibly empty). The study of various network configurations for the instruments in the nuclear core establishes that the influence of the instruments depends both on the independent instrumentation location and on the chosen network.
2011-01-11
Unsymmetrically substituted n-type perylene bisimides with liquid crystalline properties
Energy Technology Data Exchange (ETDEWEB)
Perylene bisimides (PBIs) represent an important class of organic n-type semiconductors exhibiting a relatively high electron affinity among large-band-gap materials. Herein synthesis and characterization of several unsymmetrical N-substituted PBI dyes is presented and the thermotropic behavior, which is strongly affected by the respective N-substituents was investigated. Two different series of highly soluble and fluorescent derivatives have been synthesized: (1) PBIs bearing swallow-tailed alkyl chains, different in size or (2) one swallow-tailed alkyl chain and one branched oligoethylenglycolether. Synthesis of these PBIs is generally feasible by two distinct divergent synthesis approaches. Thermotropic behavior was studied by DSC, POM and XRD measurements. Inherent {pi}-{pi} interactions between cofacially orientated perylene molecules and the elliptic shape of the molecule favor the ordering in columns and self-organized architectures. Among them hexagonal columnar ...
2009-07-01
Light Weight Composite Mirrors for Science Instruments
Light Weight Composite Mirrors for Science Instruments. Composite Optics, Inc. San Diego, CA. INNOVATION. Light weight, large aperture reflectors of graphite ...
Instrumentation for Materials Research (IMR)
... Instrumentation for Materials Research (IMR) Division of Materials Research Synopsis of Program ... for Materials Research (IMR) program in the Division of Materials Research (DMR) is designed to ...
Future instrumentation for the study of the Warm-Hot Intergalactic Medium
We briefly review capabilities and requirements for future instrumentation in UV- and X-ray astronomy that can contribute to advancing our understanding of the diffuse, highly ionised intergalactic medium.
2008-01-01
Earthquakes, Hurricanes and Stubborn ... - NASA Earth Observatory
Aug 23, 2011 ... Earthquakes, Hurricanes and Stubborn Instruments ... And if earthquakes and stubborn instruments aren't enough, there's this giant hurricane ...
EUROPEAN SPACE AGENCY Extension of the SOHO Mission
closure of the BISON network, GOLF and VIRGO will remain the only instruments ...... Faraday Cup solar wind instrument as described in Ipavich et al (1998). ...
Energy Technology Data Exchange (ETDEWEB)
Policy strategies for the promotion of electricity from renewable energy sources differ significantly among the Member States of the European Union with respect to the amount of additional installed capacity as well as concerning the country-specific support costs. The present report aims to assess the effectiveness and the economic efficiency of the support policies in the EU based on both historical experiences and prospective model-based analysis. The main message of the investigation is that the most effective policy instruments tend to be cost-efficient at the same time. In particular, feed-in tariff systems were identified as a successful instrument for supporting renewable energies in terms of effectiveness and efficiency, whereas quota systems still have to prove themselves in practice. (orig.) [German] Bezueglich des Erfolges bei der Foerderung erneuerbarer Energietraeger im Stromsektor bestehen deutliche ...
2006-09-15
Experience with pressuriser for PHT pressure control in TAPP 4 reactor
International Nuclear Information System (INIS)
In a 540 MWe PHWR reactor at TAPP-4 the pressuriser has been incorporated in the PHT pressure control system to provide the necessary vapour cushion for PHT main circuit to reduce pressure variations due to transients involving swell and shrinkage. Need for the Pressuriser is due to the large inventory in PHT main circuit and relatively large heat source. The incorporation of Pressuriser is one of the modifications while upgrading from prevalent operating 220 MWe reactors to the present 540 MWe at TAPP-4. The sizing, design and selection of the 540 MWe Pressuriser has been done w.r.t swell/shrinkage requirement during normal/transient operation of the reactor. In this paper the commissioning and operating experience of the Pressuriser in conjunction with the PHT pressure control system is presented. During light water commissioning of PHT circuit some major hurdles like failure of pressuriser heaters due to faulty instrumentation were faced. Subsequently the ...
2006-11-13
Diagnostics aid for mass spectrometer trouble-shooting
International Nuclear Information System (INIS)
The MS Expert system provides problem diagnostics for instruments used in the Mass Spectrometry Laboratory (MSL). The most critical results generated on these mass spectrometers are the uranium concentration and isotopic content data used for process control and materials accountability at the Idaho General Processing Plant. The two purposes of the system are: (1) to minimize instrument downtime and thereby provide the best possible support to the Plant, and (2) to improve long-term data quality. This system combines the knowledge of several experts on mass spectrometry to provide a diagnostic tool, and can make these skills available on a more timely basis. It integrates code written in the Pascal language with a knowledge base entered into a commercial expert system shell. The user performs some preliminary status checks, and then selects from among several broad diagnostic categories. These initial steps provide input to the rule base. The ...
Thermoelectrically cooled water trap
Energy Technology Data Exchange (ETDEWEB)
A water trap system based on a thermoelectric cooling device is employed to remove a major fraction of the water from air samples, prior to analysis of these samples for chemical composition, by a variety of analytical techniques where water vapor interferes with the measurement process. These analytical techniques include infrared spectroscopy, mass spectrometry, ion mobility spectrometry and gas chromatography. The thermoelectric system for trapping water present in air samples can substantially improve detection sensitivity in these analytical techniques when it is necessary to measure trace analytes with concentrations in the ppm (parts per million) or ppb (parts per billion) partial pressure range. The thermoelectric trap design is compact and amenable to use in a portable gas monitoring instrumentation.
2006-02-21
Energy Technology Data Exchange (ETDEWEB)
Energy projects are extremely capitalistic and the costs involved have a significant weight on the balance sheets of companies. This paper describes the general rules of financing policies used by companies from the natural gas and petroleum industries: constraints (external and financial markets, partnership, warranties..); implication of financiers; risk analysis (political (nationalization, civil or military troubles, difficult transfer of profits outside the project..), financial (property developer, nature of the project, delay, cost overruns, performance, market..)); financial instruments (proper funds and debt, bankers and insurers, loans etc..). These rules are illustrated with several examples of recent projects of gas pipelines and exploitation of oil fields abroad. (J.S.)
1997-07-01
Screening Samples with a Position-Sensitive Detection System Providing Isotope-Specific Information
International Nuclear Information System (INIS)
The properties of individual radioactive particles present in a sample, such as a swipe, are more interesting than bulk properties of the sample. The present work focuses on instrumentation that provides position-sensitive spectral information non-destructively from the sample. The experimental part of the work was realized using a device called PANDA (Particles And Non-Destructive Analysis). The detector setup used in the study contains a broad-energy HPGe gamma-ray detector and a position-sensitive alpha detector. Both detectors are connected to a time-stamping event-mode data acquisition system. The method is shown to locate particles with sub-millimetre accuracy and distinguish the interesting particles from non-interesting ones. (author)
2010-11-01
Problems of air pollution monitoring
Energy Technology Data Exchange (ETDEWEB)
The development of the monitoring network for background measurements of air pollution in the USSR is noted. The use of paired stations, to aid in locating permanent sites as well as for determining the local component of background air pollution, is described. Thermoelectric actionometers with five glass filters are used to measure Shupp's turbidity coefficient for estimating extinction of solar radiation due to aerosols. Sampling and chemical analysis of precipitation uses methods developed during the International Geophysical Year. An intercomparison of meteorological instruments was carried out in the USSR in 1973 and 1978. The most stable actinometer was the Linke-Foisner device. Chemical analyses of precipitation made since 1958 in the USSR show increases in air pollution levels only in particular areas.
1980-01-01
British Library Electronic Table of Contents (United Kingdom)
Using a novel, pulsed micro-second time-resolved photoacoustic (PA) instrument, we measured thermal dissipation and energy storage (ES) in the intact cells of wild type (WT) Chlamydomonas reinhardtii, and mutants lacking either PSI or PSII reaction centers (RCs). On this time scale, the kinetic contributions of the thermal expansion component due to heat dissipation of absorbed energy and the negative volume change due to electrostriction induced by charge separation in each of the photosystems could be readily distinguished. Kinetic analysis revealed that PSI and PSII RCs exhibit strikingly different PA signals where PSI is characterized by a strong electrostriction signal and a weak thermal expansion component while PSII has a small electrostriction component and large thermal expansion....
2011-01-01
New Public Management et professions dans l'Etat : au-dela des oppositions, quelles recompositions ?
British Library Electronic Table of Contents (United Kingdom)
More and more reforms in public administrations are being conducted that are based on the principles and instruments of ''new public management''. They have set off protest and collective actions by several professional groups in various sectors (health, education, justice, social work, research...), whence questions about the future of professional groups in public services, in particular about their autonomy, which these reforms threaten. The opposition between this new public management and certain professional groups, is not the final explanation to draw from an analysis of this situation. Should these changes be seen as the decline of professional groups and of their autonomy, as a mutation of professional models, an overhaul of professionalism, etc.? These questions, which current ev...
2011-01-01
Mining Knowledge in Astrophysical Massive Data Sets
Modern scientific data mainly consist of huge datasets gathered by a very large number of techniques and stored in very diversified and often incompatible data repositories. More in general, in the e-science environment, it is considered as a critical and urgent requirement to integrate services across distributed, heterogeneous, dynamic "virtual organizations" formed by different resources within a single enterprise. In the last decade, Astronomy has become an immensely data rich field due to the evolution of detectors (plates to digital to mosaics), telescopes and space instruments. The Virtual Observatory approach consists into the federation under common standards of all astronomical archives available worldwide, as well as data analysis, data mining and data exploration applications. The main drive behind such effort being that once the infrastructure will be completed, it will allow a new type of multi-wavelength, multi-epoch science ...
2010-01-01
Methodology for Rare Earth Element Determinations of Uranium Oxides by Ion Microprobe
British Library Electronic Table of Contents (United Kingdom)
A methodology for the determination of the rare earth elements in uranium oxides by ion microprobe has been set up on a Cameca ims-3f instrument. An uranium oxide reference material from a syn-metamorphic uranium deposit related to albitisation has also been developed for this type of analysis. Applications of the methodology are presented for a series of uranium oxides selected from some major uranium deposit types: from the world's highest grade unconformity-related uranium deposit from the Athabasca Basin (Saskatchewan, Canada; the Shea Creek and the McArthur River examples), a perigranitic vein-type deposit (Pen Ar Ran, Vendee, France) and a volcanic caldera-related deposit (Streltsovkoye, Transbaikalia, Russia). Each type of uranium deposit appears to have a specific REE signature. Al...
2007-01-01
Market based pollution abatement measures and creation of internal environmental diseconomies
Energy Technology Data Exchange (ETDEWEB)
New market based approaches are becoming increasingly important as instruments of environmental policy. The two main market approaches, i.e., transferable pollution permits (experimented in America), and 'green' energy surcharges (European philosophy), are described and discussed. An analysis of information on their state of implementation shows that, in the case of the former method, the greatest sources of difficulty arise in the determination of acceptable ceiling levels of emissions, in the distribution of permits among the various polluting firms, and in the legality of granting rights to pollute. Instead, the European experience has evidenced that energy surcharges motivated by environmental policy cannot have an appreciable positive impact on consumers or the economic system in general unless they are accompanied by well defined measures geared towards the promotion or creation of alternative solutions such as to ...
1991-09-01
Instruments for X-ray fluorescence analysis and spectrometry
International Nuclear Information System (INIS)
The radionuclide X-ray fluorescence analyzer consists of a source changer and a sample changer. "5"5Fe, "1"0"9Cd and "2"4"1Am are used as excitation sources. The radiation is detected with a semiconductor Si(Li) detector. The complete assembly of the apparatus consists of an imagine unit, a keyboard, a floppy disc drive, a printer, a console and a rack with analog and digital electronics. Its multichannel amplitude analyzer consists of power supplies, a high voltage supply, a linear amplifier, an analog-to-digital converter and a computer. The technical specifications are given. The control and data processing system is controlled with an MHB 8080A microprocessor. Software for semiconductor gamma spectrometry and for quantitative gamma spectrometry will be supplied with the equipment. (E.S.). 3 figs., 4 refs.
Hyperspectral remote sensing for mineral exploration in Pulang, Yunnan Province, China
British Library Electronic Table of Contents (United Kingdom)
The launch of the first spaceborne hyperspectral instrument, Hyperion, in 2000 has provoked further research into its capabilities with regard to mineral exploration. Our study in the remote, mountainous region of Pulang, China employed a two-step progressive approach, first to locate target areas characterized by hydrothermal mineral alteration, using the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER), and secondly, to attempt detailed mineral mapping using Hyperion. The preliminary target detection involved principal components and broad-band spectral analysis and led to the detection of two target areas characterized by argillic alteration, iron-oxide- and sulphate-bearing minerals. A focused hyperspectral study followed using Spectral Angle Mapper (SAM) and Mixt...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The transmission of electrical energy by use of underground cables is increasing. Fault location techniques have certain limitations; incipient fault detection and location would help reduce the maintenance cost of these lines as well as improve the reliability of service. The report discusses some test results related to RF-probing techniques applied to high-voltage transmission lines. The high-frequency losses and attenuation in high-voltage cables places certain ultimate limitations on RF-probing techniques for incipient fault detection. Time-domain reflectrometry methods were employed to assess the RF-transmission properties of high-voltage cables at frequencies as high as 6 GHz. Fast-Fourier-transform deconvolution was used to obtain loss measurements as a function of frequency. The loss mechanisms were identified. The measurement hardware and methods are discussed as well as analysis approach leading to the conclusions.
1986-04-01
Energy Technology Data Exchange (ETDEWEB)
The use of differential absorption and Raman scattering techniques for the remote sensing of methane in underground coal mines is examined. An analysis of the differential absorption technique showed that non-range resolved systems were incapable of achieving the desired concentration and range specifications and therefore were unsuitable for use in underground coal mines. The Raman scattering technique proved quite successful and a conceptual design which uses the technique is presented. The availability of suitable UV source is critical to the success of the technique however, and to date there is nothing which meets size and portability requirements for a system of this type. Recommendations for further study are included. 19 refs.
1986-04-01
Design of Reactor Head Structure Assembly Using Axiomatic Design
Energy Technology Data Exchange (ETDEWEB)
The Reactor Head Structure Assembly(RHSA) is the structure located on the reactor assembly. The purpose of the assembly is providing interface location for cables, preventing pipe whips, prohibiting instruments from becoming missiles, and restraining CEDMs' horizontal motion. On the RHSA, Reactor Disconnect Panels(RDP) are installed. The installation location of RDP is to be decided to minimize the geometric interface with other components. Since the neighborhood of RHSA is crowded due to many connectors and cables, it is necessary to find the good design of RHSA to make an intricate situation attenuated and the required function maintained. The geometric shape and overall configuration of RHSA are determined by axiomatic design approach. The FRs of RHSA are specified and the corresponding DPs are found to satisfy FRs in sequence. The finite element analysis is carried out based on the result of the axiomatic design to evaluate the ...
2007-07-01
Constraining SN Ia Models Using X-ray Spectra of Clusters of Galaxies
We present constraints on theoretical models of Type Ia SNe using spatially resolved ASCA X-ray spectroscopy of four galaxy clusters: Abell 496, Abell 2199, Abell 3571 & Perseus. All four clusters have central Fe abundance enhancements and an ensemble of abundance ratios are used to show that most of the Fe in the central regions of the clusters comes from SN Ia. At the center of each cluster, simultaneous analysis of spectra from all ASCA instruments shows that the Ni to Fe abundance ratio (normalized by the solar ratio) is ~ 4. We use the Ni/Fe ratio as a discriminator between SN Ia explosion models: the Ni/Fe ratio of ejecta from the "Convective Deflagration" model W7 is consistent with the observations, while those of "delayed detonation" models are not consistent at the 90% confidence level.
2000-01-01
Cleansing methodology of sites and its applications
International Nuclear Information System (INIS)
The Commissariat a l'Energie Atomique (CEA, French Atomic Energy Commission) has set up over the last 10 years an innovative methodology aiming at characterizing radiological contaminations. The application of the latter relies on various tools such as expertise vehicles with impressive detection performances (VEgAS) and recently developed software platform called Kartotrak. A Geographic Information System tailored to radiological needs constitutes the heart of the platform; it is surrounded by several modules aiming at sampling optimization (Stratege), data analysis and geostatistical modeling (Krigeo), real-time monitoring (Kartotrak- RT) and validation of cleaning efficiency (Pescar). This paper presents the different tools which provide exhaustive instruments for the follow-up of decontamination projects, from doubt removal to the verification of the decontamination process. (authors)
2009-10-12
Care programmes and integrated care pathways
British Library Electronic Table of Contents (United Kingdom)
Purpose - The article discusses how care programmes and integrated care pathways can be linked, finding ways to improve healthcare process professional and logistical quality from a supply chain and a network point-of-view. Design/methodology/approach - The authors argue that owing to cost containment goals and increasing healthcare demand, healthcare services systems are challenged to improve service quality, whilst at the same time finding ways to improve delivery processes. It explores if the combination of two instruments, care programmes and integrated care pathways, can meet both goals. This combination is illustrated by an example from the Institute of Mental Health Care Eindhoven en de Kempen. Findings - Analysis suggests that care programmes can be combined with integrated care pa...
2008-01-01
A mobile remote sensing laboratory for water vapor, trace gas, aerosol, and wind speed measurements
Energy Technology Data Exchange (ETDEWEB)
The Lawrence Livermore National Laboratory has developed a mobile field laboratory for remote measurement of atmospheric processes and observables that are important in global climate change, dispersal of hazardous materials, and atmospheric pollution. Specific observables of interest are water vapor, trace gases, aerosol size and density, wind, and temperature. The goal is to study atmospheric processes continuously for extended periods in remote field locations. This laboratory has just reached field ready status with sensors for aerosol and trace gas measurement based on established techniques. A development program is underway to enhance the sensor suite with several new techniques and instruments that are expected to significantly extend the state of the art in remote trace gas analysis. The new sensors will be incorporated into the lab during the next two years.
1993-03-19
The Cross-Calibration of Swift-BAT and Fermi-GBM via Correlative Spectral Analysis of GRBs
We report on recent inter-calibration studies featuring Swift's Burst Alert Telescope (BAT) and Fermi's Gamma-ray Burst Monitor (GBM) based upon correlated observations of GRBs 080804 and 080810, via their resultant joint spectral analysis. Swift's intrinsic multi-wavelength instrumentation and dynamical response complement Fermi's superior energy range. The addition of BAT's spectral response will (i) facilitate in-orbit GBM detector response calibration, (ii) augment Fermi's low energy sensitivity, (iii) enable ground-based follow-up efforts of Fermi GRBs, and (iv) help identify a subset of GRBs discovered via off-line GBM data analysis, for an annual estimate of ~30 GRBs. The synergy of BAT and GBM augments previous successful joint spectral fit efforts by enabling the study of peak photon energies (Epeak), while leveraging the over eleven energy decades afforded by Fermi's Large Area Telescope (LAT), in conjunction with ...
2009-01-01
Systems Analysis of Safeguards Effectiveness in a Uranium Conversion Facility
Energy Technology Data Exchange (ETDEWEB)
The U.S. Department of Energy (DOE) is interested in developing tools and methods for potential U.S. use in designing and evaluating safeguards systems. For this goal several DOE National Laboratories are defining the characteristics of typical facilities of several size scales, and the safeguards measures and instrumentation that could be applied. Lawrence Livermore National Laboratory is providing systems modeling and analysis of facility and safeguards operations, diversion path generation, and safeguards system effectiveness. The constituent elements of diversion scenarios are structured using directed graphs (digraphs) and fault trees. Safeguards indicator probabilities are based on sampling statistics and/or measurement accuracies. Scenarios are ranked based on value and quantity of material removed and the estimated probability of non-detection. Significant scenarios, especially those involving timeliness or randomly varying order of ...
2004-06-16
Neutron activation analysis of Permian-Triassic (P-Tr) boundary layer at Selong site in China
Energy Technology Data Exchange (ETDEWEB)
Since living things began their activities on the earth, the extermination of living things in large number on global scale occurred twice 230 million years ago (P-Tr boundary) and 65 million years ago (K-T boundary). As to the cause of exterminating living things in short period, there are volcano eruption theory, meteorite collision theory and so on, but still it is not decided. Therefore, as to the strata of P-Tr boundary in south-western part of China where it has been known the preservation of P-Tr strata is especially good, the existence of elements was measured by instrument neutron activation analysis and ICP-MS, and the state of change was examined. According to the results, the change occurred at the P-Tr boundary on the earth, and further, the possibility of meteorite collision by paying attention to Ir were examined. The samples, the neutron activation analysis, the ICP-MS and the results are reported. The ...
1994-07-01
Energy Technology Data Exchange (ETDEWEB)
This dissertation has presented the results from analysis of medicinal plant extracts using neutron activation method. Instrumental neutron activation analysis was applied to the determination of the elements Al, Br, Ca, Ce, Cl, Cr, Cs, Fe, K, La, Mg, Mn, Na, Rb, Sb, Sc and Zn in medicinal extracts obtained from Achyrolcline satureoides DC, Casearia sylvestris, Centella asiatica, Citrus aurantium L., Solano lycocarpum, Solidago microglossa, Stryphnondedron barbatiman and Zingiber officinale R. plants. The elements Hg and Se were determined using radiochemical separation by means of retention of Se in HMD inorganic exchanger and solvent extraction of Hg by bismuth diethyl-dithiocarbamate solution. Precision and accuracy of the results have been evaluated by analysing reference materials. The therapeutic action of some elements found in plant extracts analyzed was briefly discussed 70 refs., 13 figs., 15 tabs
1995-12-31
Tropospheric sampling with aircraft
Energy Technology Data Exchange (ETDEWEB)
Aircraft constitute a unique environment which places stringent requirements on the instruments used to measure the concentrations of atmospheric trace gases and aerosols. Some of these requirements such as minimization of size, weight, and power consumption are general; others are specific to individual techniques. This review presents the basic principles and considerations governing the deployment of trace gas and aerosol instrumentation on an aircraft. An overview of common instruments illustrates these points and provides guidelines for designing and using instruments on aircraft-based measurement programs.
1991-03-01
Linearization of nondestructive radiation testing instruments using television technique
International Nuclear Information System (INIS)
(1985). USSR Nedavnij, OI Tomskij Politekhnicheskij Inst. (USSR).
DEVELOPMENT OF THE PILOT WARNING INSTRUMENT ...
... multivibrators and amplifiers arranged to operate as described above. ... The first of the multivibrators is triggered by the trailing edge of the ...
1962-02-01
Preliminary Design of ARIES-Devasthal Faint Object Spectrograph and Camera
We present here the preliminary design of ARIES-Devasthal Faint Object Spectrograph and Camera (ADFOSC), which is a multi-mode instrument for both imaging and spectroscopy. ADFOSC is the first-generation instrument to be mounted at the axial port of the Cassegrain focus on our new 3.6m optical telescope to be installed at Devasthal, Nainital. The main design goals of the instrument are : the instrument will have capability of broad- and narrow-band imaging, low-medium resolution spectroscopy, and imaging polarimetry. The operating wavelength range will be from 360 to 1000 nm and the instrument will have remote-control capability.
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
The overall goal of the DOE fine particulate program is to ensure that the best science and technology is available for any regulatory decision-making related to the health and environmental impacts of ambient fine particulate matter and regional haze. Interest primarily lies in the particulate fraction having aerodynamic diameters of 2.5 microns and less (PM2.5). Particulates of this size are the focus of the newly established National Ambient Air Quality Standards. As such, the Federal Energy Technology Center (FETC) is establishing a fine particulate sampling station at the Center's Pittsburgh site located in South Park Township, PA. This sampling station is one of a group of stations scattered throughout Pennsylvania, West Virginia, and Ohio that constitute the Upper Ohio River Valley Project. The station is equipped with a full complement of fine particulate and gaseous monitors including the following: (1) R and P Sequential FRM sampler, (2) Grimm PM2.5 continuous ...
1999-07-01
Investigation of thermohydraulic parameters during natural convection cooling of TRIGA reactor
International Nuclear Information System (INIS)
Important steady-state thermohydraulic parameters of the TRIGA research reactor operating under natural convection mode of coolant flow were investigated using NCTRIGA computer code. Neutronic parameters used in preparing the input of NCTRIGA were taken from the analysis performed by 3-D Monte Carlo code MCNP4C. Benchmarking of the NCTRIGA calculated results were performed against the experimental data measured by the thermocouples in the instrumented fuel element (IFE) during the steady state operation of the reactor under natural convection mode of coolant flow. Various thermohydraulic parameters like the coolant velocity, flow rate and mass flow rate were generated for the hot channel as well as for the two channels comprising instrumented fuels. Calculated peak fuel temperatures at different power levels were compared with the measured values and also with the calculations performed by PARET code. Axial temperature ...
2006-09-01
Determination of sodium in biological samples by instrumental neutron activation analysis
International Nuclear Information System (INIS)
Sodium is one of the most essential elements needed for metabolic processes amongst human beings. It is consumed in the form of sodium chloride but it is also present in edible plant leaves. Sodium is mostly analyzed by flame photometric method, a destructive and time consuming technique. Sodium has been determined in some green leave vegetables samples-palak, radish, khatta palak (ambat chuka), chaulai leaves, chauli bean covers and its seeds by instrumental neutron activation analysis. The method involves irradiation of samples with thermal neutrons from "2"4"1Am-Be source and counting "2"4Na activity (half life 15 hr) from the reaction "2"3Na(n,#gamma#) "2"4Na. Activity due to 1.37 MeV photopeak was counted with a NaI(Tl) crystal coupled to gamma ray spectrometer. Green leaves of the vegetables were thoroughly washed, dried at constant temperature and powdered. Bowen's Kale powder was used as standard for measuring sodium abundances. About ...
1981-05-01
International Nuclear Information System (INIS)
Korea Atomic Energy Research Institute, using the ANS Low Power /Shutdown (LPSD)PRA Standard, evaluated the LPSD PSA model of the KSNP, Younggwang (YGN) Units 5 and 6, and identified the items to be improved. The evaluation results of human reliability analysis (HRA) of the pre-accident human errors in the LPSD PSA model of the KSNP showed that 13 items among 15 items of supporting requirements for those in the ANS PRA Standard were identified as them to be improved. Thus, we newly carried out a HRA for pre-accident human errors in the LPSD PSA model for the KSNP to improve its quality. We considered potential pre-accident human errors for all manual valves and control/instrumentation equipment of the systems modeled in the KSNP LPSD PSA model except reactor protection system/ engineering safety features actuation system. We reviewed 160 manual valves and 56 control/instrumentation equipment. The number of newly identified ...
2003-04-20
Skeletal remodeling dynamics: New approaches with imaging instrumentation
Energy Technology Data Exchange (ETDEWEB)
This report of progress and future objectives timetable is based on an included schematic of goals and objectives and the project abstract which is included as Appendix 1. Five matters are summarized in the order of (1) novel methods of calcified bone confocal microscopy and reconstruction image analysis of decalcified beagle and human cortical bone serial sections, (2) macroscopic cross-correlation of beagle and human cortical and cancellous bone fractions with CT analysis, (3) guidance to the most radiobiologically important skeletal regions of interest with the just completed {sup 90}Sr bone tumor map from life time beagle studies, (4) deposition patterns of radioactive agents that participate in apatite crystal nucleation processes in bone and leave radiation-excited electrons trapped in bone mineral, and (5) the budget period timetable. The discovery that beta particles from {sup 166}Ho (T{sub {1/2}} =26 hr, {beta}{sub max} = 1.8 MeV) ...
1991-12-01
Energy Technology Data Exchange (ETDEWEB)
Detailed investigations of geologic, geomorphic, and seismic conditions at the Bodo Canyon disposal site were conducted. The purpose of these investigations was basic site characterization and identification of potential geologic hazards that could affect long-term site stability. Subsequent engineering studies, such as analyses of hydrologic and liquefaction hazards, used the data developed in these studies. The geomorphic analysis was employed in the design of effective erosion protection. Studies of the regional and local seismotectonic setting, which included a detailed search for possible capable faults within a 65 kilometer radius of the site, provided the basis for seismic design parameters. The scope of work performed included the following: Compilation and analysis of previous published and unpublished geologic literature and maps; Review of historical and instrumental earthquake data; Review of site-specific ...
1991-12-01
Iridium and PGE in sedimentary rocks; Iridium et platinoides dans les roches sedimentaires
Energy Technology Data Exchange (ETDEWEB)
The detection limit of Instrumental Neutron Activation Analysis (INAA), about a few microgram per kg, is not sufficient to determine iridium concentrations in most geological samples. Use of the coincidence counting of the 316 and 468 keV gamma-rays emitted during the decay of {sup 192}Ir, improved the sensitivity (0.01 microgram per kg). The high iridium content of the clay layers from the Cretaceous-Tertiary transition (KTB) has been considered as an evidence of the extra-terrestrial origin of the KTB mass extinction. However some results indicate that a significant part of the iridium content in sediments has a volcanic origin. Radiochemical Neutron Activation Analysis (RNAA) in some KTB samples and in basic and ultra-basic rocks show that, unlike in volcanic products, no PGE (platinoids) fractionation appears in KTB samples. The nearby chondritic PGE pattern supports an extra-terrestrial origin for the KTB iridium ...
1994-12-31
Direct sampling ion trap mass spectrometry (DSITMS). Innovative technology summary report
Energy Technology Data Exchange (ETDEWEB)
This report describes the cost, performance, and other key characteristics of an innovative technology for determining the presence or absence, and measuring the concentration, of volatile organic compounds (VOCs) and semi-volatile organic compounds (SVOCs) in groundwater and soil, and in gaseous remediation process streams at hazardous waste sites. This new technology is Direct Sampling Ion Trap Mass Spectrometry (DSITMS). DSITMS introduces sample materials directly into an ion trap mass spectrometer by means of a very simple interface, such as a capillary restrictor or a polymer membrane. There is typically very little, if any, sample preparation and no chromatographic separation of the sample constituents. This means that the response of the instrument to the analytes or contaminants in a sample is nearly instantaneous, and that analytical methods based on DSITMS are fast. Analyses are typically completed in less than five minutes, and the ...
1998-12-01
BWR stability analysis at Brookhaven National Laboratory
Energy Technology Data Exchange (ETDEWEB)
Following the unexpected, but safely terminated, power and flow oscillations in the LaSalle-2 Boiling Water Reactor (BWR) on March 9, 1988, the Nuclear Regulatory Commission (NRC) Offices of Nuclear Reactor Regulation (NRR) and of Analysis and Evaluation of Operational Data (AEOD) requested that the Office of Nuclear Regulatory Research (RES) carry out BWR stability analyses, centered around fourteen specific questions. Ten of the fourteen questions address BWR stability issues in general and are dealt with in this paper. The other four questions address local, out-of-phase oscillations and matters of instrumentation; they fall outside the scope of the work reported here. It was the purpose of the work documented in this report to answer ten of the fourteen NRC-stipulated questions. Nine questions are answered by analyzing the LaSalle-2 instability and related BWR transients with the BNL Engineering Plant Analyzer (EPA) and by performing an ...
1991-12-31
International Nuclear Information System (INIS)
This specialist meeting on Advanced Instrumentation and Measurements Techniques was held in Santa Barbara (USA) in 1997 and attracted some 70 participants in ten technical sessions and a session of the round table discussions, with a total of 41 papers. It was intended to bring together the international experts in multi-phase flow instrumentation, experiment and modeling to review the state-of-the-art of the two-phase flow instrumentation methods and to discuss the relation between modeling needs and instrumentation capabilities. The following topics were included: Modeling needs and future direction for improved constitutive relations, interfacial area transport equation, and multi-dimensional two-fluid model formulation; local instrumentation developments for void fraction, interfacial area, phase velocities, turbulence, entrainment, particle size, thermal non-equilibrium, shear ...
1997-03-17
Large sample NAA facility at GRR-1 research reactor: Design and applications
International Nuclear Information System (INIS)
Full text: A Large Sample Neutron Activation Analysis (LSNAA) facility is under development at GRR-1 research reactor, NCSR 'Demokritos'. The LSNAA facility design incorporates sample irradiation in the reactor's graphite thermal neutron column and subsequent measurement of the activity induced at a gamma spectroscopy system with gamma ray transmission measurement options included. Monte Carlo neutron and photon transport code MCNP-4C was used to model the facility. Appropriate correction factors accounting for neutron field perturbation during sample irradiation, high purity germanium detector efficiency for the volume source and gamma ray self-absorption within the sample itself were derived. The results of the computations were experimentally verified by activation foil measurements for a set of known materials and a range of sample sizes extending up to 10 litters. Moreover, the special issue of large sample analysis of non-homogeneous ...
2003-06-09
Energy Technology Data Exchange (ETDEWEB)
RangerMaster{trademark} is the embedded firmware for Quantrad Sensor`s integrated nuclear instrument package, the Ranger{trademark}. The Ranger{trademark}, which is both a gamma-ray and neutron detection system, was originally developed at Los Alamos National Laboratory for in situ surveys at the Plutonium Facility to confirm the presence of nuclear materials. The new RangerMaster{trademark} software expands the library of isotopes and simplifies the operation of the instrument by providing an easy mode suitable for untrained operators. The expanded library of the Ranger{trademark} now includes medical isotopes {sup 99}Tc, {sup 201}Tl, {sup 111}In, {sup 67}Ga, {sup 133}Xe, {sup 103}Pa, and {sup 131}I; industrial isotopes {sup 241}Am, {sup 57}Co, {sup 133}Ba, {sup 137}Cs, {sup 40}K, {sup 60}Co, {sup 232}Th, {sup 226}Ra, and {sup 207}Bi; and nuclear materials {sup 235}U, {sup 238}U, {sup 233}U, and {sup 239}Pu. To accomplish isotopic ...
1998-12-31
Energy Technology Data Exchange (ETDEWEB)
New furnaces were built based on fused silica with NiChrome heating elements custom-wound on alumina ceramic to self-compensate for induced magnetic fields during operation. During tests these furnaces failed due to thermal stresses caused by the high temperature cement used to hold the alumina ceramic in place. As a third solution pieces of boron nitride have been procured from which new furnace bodies will be machined during the third quarter. In order to increase the in-house capacity for machining ceramic parts a small lathe was ordered. The implementation of the LabView data acquisition software from National Instruments, Inc. took more time than anticipated and is still not completed. Major difficulties had to be overcome during the integration of the separate positive and negative high voltage supplies ({plus_minus}1000V). It became apparent that a custom-designed switch had to be installed to safeguard the data acquisition modules and the Apple Macintosh ...
1993-11-01
Advanced Method for In-Field Measurement, Monitoring and Verification of Total Soil Carbon
The Earth`s oceans, forests, agricultural lands and other natural areas absorb about half of the carbon dioxide emitted from anthropogenic sources. Terrestrial carbon sequestration strategies are immediately available to bridge the gap between current terrestrial sequestration capacity and high-capacity geologic sequestration projects available in 10 to 20 years. Terrestrial carbon sequestration strategies consist of implementing land management practices aimed at decreasing CO2 emitted into the atmosphere and developing advanced measurement tools to inventory and monitor carbon processes in soils and biota. In addition to atmospheric CO2 mitigation and carbon trading advantages, terrestrial carbon sequestration produces a variety of benefits which include reclamation of degraded lands, increased soil productivity, increased land value and a more secure food source. Carbon storage in soil depends on climate and management practices, with potential yearly increases estimated from 0 ...
2005-12-01
Measurement of Sexual Functioning After Spinal Cord Injury: Preferred Instruments
UK PubMed Central (United Kingdom)
Background/Objective:To determine the utility of certain instruments to assess sexuality and fertility after SCI, an expert panel identified key areas to study and evaluated...Full Text Available
2009-06-01
Maintenance and fabrication of electronic equipment
Energy Technology Data Exchange (ETDEWEB)
Solving the maintenance and repair problems of electronic instruments, we have supported the research and development work, and reduced operation costs of the pilot plants in KAERI. In addition, we have improved the maintainability of instruments to use effectively. 18 tabs., 17 figs., 13 refs. (Author) .new.
1995-12-01
Maintenance and fabrication of electronic equipment
Energy Technology Data Exchange (ETDEWEB)
Solving the maintenance and repair problems of electronic instruments, we have supported the research and development work, and reduced operation costs of the pilot plants in KAERI. In addition, we have imposed the maintainability of instruments to use effectively. 15 tabs., 14 figs., 14 refs. (Author) .new.
1994-12-01
Instrumentation and Controls Division progress report, July 1, 1982-July 1, 1984. Volume 1
Energy Technology Data Exchange (ETDEWEB)
Progress is briefly summarized for a large number of projects in the areas of research instruments, measurement and controls engineering, reactor systems, and maintenance management. (LEW)
1984-12-01
Granite Countertops and Radiation | Radiation Protection | US EPA
... Top of page Testing Radiation coming from granite countertops results from natural radioactive material in the granite. Identifying the presence and concentration of radioactive elements in granite requires expensive and sophisticated portable instruments or laboratory equipment. These instruments and equipment require proper calibration, and interpretation of ...
An Instrumented Range Meeting the Requirements of a Wound Ballistics Small Arms Program.
Instrumentation, equipment, and space requirements are outlined which would satisfy a portion of the needs of the Wound Ballistics Program of research into the terminal behavior of missiles from a variety of antipersonnel munitions (fragments, flechettes,...
1968-01-01
A FEASIBILITY STUDY OF A POCKET-SIZED GAS CHROMATOGRAPHIC AIR ANALYZER
The feasibility of producing a pocket-sized air contaminant monitor based upon a miniature gas chromatograph and an integrated microcomputer has been demonstrated and a practical design for the instrument is presented. This pocket-sized instrument is intended to be used as a pers...
ALOS satellite imagery utilizations for safeguards
International Nuclear Information System (INIS)
This paper introduces examples of satellite imageries analysis and utilizations for safeguards activities. Recently, many kinds of satellite imageries are available in the world i.e., high-spatial resolution, multi- and hyper-spectral, multi-function, and multi-polarization radars. The problem is that how to obtain the required information from these digital images. The Japan Aerospace Exploration Agency (JAXA) has successfully launched the Advanced Land Observing Satellite (ALOS, the nickname is 'Daichi') on 24th January, 2006. The mission objectives are cartography, regional observation, disaster monitoring etc. ALOS has three instruments, PRISM, AVNIR-2, and PALSAR, to achieve these objectives. An overview of ALOS is provided. ALOS follows the Japanese Earth Resources Satellite- 1 (JERS-1) and the Advanced Earth Observing Satellite (ADEOS) and utilizes advanced land-observing technology. ALOS is fling in a Sun-synchronous orbit with an ...
2006-10-16
International Nuclear Information System (INIS)
Development and deployment of small-scale nuclear power reactors and their maintenance, monitoring, and control are part of the mission under the Small Modular Reactor (SMR) program. The objectives of this NERI-consortium research project are to investigate, develop, and validate advanced methods for sensing, controlling, monitoring, diagnosis, and prognosis of these reactors, and to demonstrate the methods with application to one of the proposed integral pressurized water reactors (IPWR). For this project, the IPWR design by Westinghouse, the International Reactor Secure and Innovative (IRIS), has been used to demonstrate the techniques developed under this project. The research focuses on three topical areas with the following objectives. Objective 1 - Develop and apply simulation capabilities and sensitivity/uncertainty analysis methods to address sensor deployment analysis and small grid stability issues. Objective 2 - Develop and test an ...
2009-02-23
Tactile Instrument for Aviation
... electrocutaneous stimuli, and the nerve fibres innervating ... layer or at the epidermal-dermal interface. ... 2) Vestibular prosthesis and for limb prosthesis ...
2000-07-30
THE APPLICATION OF STATISTICS TO THE FLIGHT ...
... Measuring Instruments ..... 7-18 7.4 Power Spectral Density Measurements of Random DaL. .... 7-19 7 ...
1961-12-01
Plasma treatment of polymer dielectric films to improve capacitive energy storage
Demand for compact instrumentation, portable field equipment, and new electromagnetic weapons is
1994-01-01
Instrumentation in Support of Interactive Visualization ...
... By virtual environments, we meant an immersive visual and audio technology such that experimenter has little or no awareness of the real ...
1997-06-01
Electron-Induced Luminescence and X-Ray Spectrometer (ELXS) System for Life Detection
The ELXS concept is a novel, portable, micro-instrument targeted for the detection of mineralogic
2002-01-01
... many intriguing new possibilities in the materials sciences. Or consider solitons, a mathematical ... point out that advanced instrumentation, new materials, novel production methods, and efficient ...
02.10.10 - NASA and Texas Instruments are using the theme of human space exploration to develop digital libraries of math and science problems for high ...
Instrumentation and Controls Division biennial progress report, September 1, 1978-September 1, 1980
Energy Technology Data Exchange (ETDEWEB)
Brief summaries of research work are presented in the following section: overview of the ORNL Instrumentation and Controls Division activities; new developments and methods; reactor instrumentation and controls; measurement and control engineering; electronic engineering; maintenance; studies; services; and development; and division achievements.
1981-06-01
Calibration curves of a PGNAA system for cement raw material analysis using the MCNP code
Energy Technology Data Exchange (ETDEWEB)
In large samples, the {gamma}-ray count rate of a prompt gamma neutron activation analysis system is a multi-variable function of the elemental dry composition, density, water content and thickness of the material. The experimental calibration curves require tremendous laboratory work, using a great number of standards with well-known compositions. Although a Monte Carlo simulation study does not avoid the experimental calibration work, it reduces the number of experimental calibration standards. This paper is part of a feasibility study for a PGNAA system for on-line continuous characterisation of cement raw material conveyed on a belt (Oliveira, C., Salgado, J. and Carvalho, F. G. (1997) Optimisation of PGNAA instrument design for cement raw materials using the MCNP code. J. Radioanal. Nucl. Chem. 216(2), 191-198; Oliveira, C., Salgado, J., Goncalves, I. F., Carvalho, F. G. and Leitao, F. (1997a) A Monte Carlo study of the influence of ...
1998-12-01
X-ray microanalysis of Al/Zr multilayers in the transmission electron microscope
International Nuclear Information System (INIS)
A one-nanometer scale transmission electron microscope electron probe X-ray microanalysis characterization of as-deposited and annealed aluminum--11.5 at.% zirconium multilayer samples in cross-section synthesized by magnetron sputtering is reported on here. Composition line profiles were acquired across Zr layers in as-deposited material and samples isochronally annealed in a differential scanning calorimeter to temperatures of 290 C and 485 C. A spatial resolution of approximately 1.5 to 2.0 nm was achieved in these experiments and will be improved by deconvolution of the instrumental electron probe function from the data. The as-deposited structure consisted of crystalline Al and Zr layers with thin amorphous layers at the Al/Zr interfaces. The amorphous interface layers increased in thickness upon annealing to 290 C. Additionally, at 290 C a metastable cubic alloy forms at the Zr deposited on Al interface. Upon heating to 485 C a multilayer of Al and metastable ...
1997-04-04
WIDGET: System Performance and GRB Prompt Optical Observations
The WIDeField telescope for Gamma-ray burst Early Timing (WIDGET) is used for a fully automated, ultra-wide-field survey aimed at detecting the prompt optical emission associated with Gamma-ray Bursts (GRBs). WIDGET surveys the HETE-2 and Swift/BAT pointing directions covering a total field of view of 62 degree x 62 degree every 10 secounds using an unfiltered system. This monitoring survey allows exploration of the optical emission before the gamma-ray trigger. The unfiltered magnitude is well converted to the SDSS r' system at a 0.1 mag level. Since 2004, WIDGET has made a total of ten simultaneous and one pre-trigger GRB observations. The efficiency of synchronized observation with HETE-2 is four times better than that of Swift. There has been no bright optical emission similar to that from GRB 080319B. The statistical analysis implies that GRB080319B is a rare event. This paper summarizes the design and operation of the WIDGET system and the simultaneous GRB ...
2010-01-01
Variation of elements in self-burning coal seam from Coalspur, Alberta, Canada
Energy Technology Data Exchange (ETDEWEB)
The elemental and mineralogical variation in a self-burning coal seam from Coalspur, Alberta, is determined using instrumental neutron activation analysis (INAA) and x-ray diffraction (XRD). The elemental variation in the coal seam is related to temperatures in the various alteration zones, i.e., oxidation, combustion, or carbonization and nature of elements. Mobilization of elements is greatest for As, Br, Cl, Mo, N, S, and Sb. Some of these elements are released to the atmosphere, as evident by the presence of orthorombic sulfur crystals on the surface or in vents at the top of the burning seam or saturation of oxidation char by volatile matter (tar). Whewellite (CaC{sub 2}O{sub 4}, H{sub 2}O) is the only Ca-bearing mineral found in the cooler area of the coal seam. Decomposition of this mineral, coupled with the presence of SO{sub 2} formed by reaction of organic sulfur with O{sub 2} in combustion, resulted in formation of a relatively high ...
1990-01-01
Transient data acquisition techniques under EDS
Energy Technology Data Exchange (ETDEWEB)
This paper is the first of a series which describes the Enrichment Diagnostic System (EDS) developed for the MARS project at Lawrence Livermore National Laboratory. Although EDS was developed for use on AVLIS, the functional requirements, overall design, and specific techniques are applicable to any experimental data acquisition system involving large quantities of transient data. In particular this paper will discuss the techniques and equipment used to do the data acquisition. Included are what types of hardware are used and how that hardware (CAMAC, digital oscilloscopes) is interfaced to the HP computers. In this discussion the author will address the problems encountered and the solutions used, as well as the performance of the instrument/computer interfaces. The second topic the author will discuss is how the acquired data is associated to graphics and analysis portions of EDS through efficient real time data bases. This discussion will ...
1985-06-01
The cosmic-ray antiproton spectrum between 0. 1 and 1. 5 GeV kinetic energy
Energy Technology Data Exchange (ETDEWEB)
In the summer of 1980, a balloon-borne cosmic ray experiment reported the detection of 14 low energy antiprotons during an 18 hour flight. This measurement represented an antiproton intensity two orders of magnitude greater than that predicted by conventional theories. This surprising result triggered a flurry of papers theorizing the origin of these particles, including the prediction of domains of primary antimatter, and evidence for supersymmetric particle annihilation. Not until the summer of 1987 was a follow up experiment (PBAR) performed. The PBAR detector has both better resolution and a larger dynamic range in energy than the previous detector. It measured the energy spectrum of antiprotons in the 0.1-1.5 GeV kinetic energy range. The present work describes the instrument, the experiment, and the results. Our analysis of the PBAR data reveals no antiprotons in the energy range of 0.13-0.64 GeV and only one antiproton candidate for ...
1988-01-01
Review of progress in quantitative NDE. Abstracts
Energy Technology Data Exchange (ETDEWEB)
The meeting was arranged into the following sessions: introductory; advanced ceramics and ceramic composites; ceramic and metal matrix composites; electronic materials and devices; acoustoelasticity, stress, and texture; composites-porosity, strength, and UT propagation; process modeling and monitoring; thermal wave physics; material properties, composites, surfaces, and interfaces; acoustic emission; ferromagnetic materials; new sensors; NDE reliability assessment; elastic wave scattering and propagation; image analysis, data storage, and signal processing; UT transducers; weldments and bonded materials; eddy current models; unified life cycle engineering; x rays, CT, and NMR; eddy current probes and instruments; acoustic microscopy imaging, and reconstruction; signal processing, measurement techniques, and systems; NDE applications of artificial intelligence; crack behavior influenced by history; inversion procedures for UT and EC; process ...
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
One aspect of the research program SFB 570 'Distortion engineering' is the in situ X-Ray diffraction analysis of phases and residual stresses during complete heat treatment cycles. These investigations result in experimental evidence available for the extensive computations. The optimisation of the instrumentation will be reported. A surface decarburisation of samples made from the ball bearing steel 100Cr6 could be avoided for a temperature range from 800 to 900 C and a holding time of one hour by a combination of evacuate the furnace and using a certain nitrogen flow as protective gas. At lower temperatures small amounts of ferrite caused by an increased diffusion rate of carbon lead again to a surface decarburisation up to a depth of 2 {mu}m. It was proved that with an evacuation of the X-Ray beam path at constant power of the X-Ray source the intensity of diffraction lines could be increased by more than a factor of 4. The ...
2007-07-01
Quantitative monitoring of the fluorination process by neutron counting
Energy Technology Data Exchange (ETDEWEB)
Plutonium metal is produced by reducing PuF{sub 4} prepared from PuO{sub 2} by fluorination. Both fluorination and reduction are batch processes at the Los Alamos Plutonium Facility. The conversion of plutonium oxide to fluoride greatly increases the neutron yield, a result of the high cross section for alpha-neutron ({alpha},n) reactions on fluorine targets compared to the (more than 100 times) smaller {alpha},n yield on oxygen targets. Because of the increase, total neutron counting can be used to monitor the conversion process. This monitoring ability can lead to an improved metal product, reduced scrap for recycle, waste reduction, minimized reagent usage, and reduce personnel radiation exposures. A new stirred-bed fluorination process has been developed simultaneously with a recent evaluation of an automated neutron-counting instrument for quantitative process monitoring. Neutrons are counted with polyethylene-moderated {sup 3}He-gas proportional counters. ...
1993-12-31
Energy Technology Data Exchange (ETDEWEB)
This paper presents the experience faced by people who works in PETROBRAS Business Unit (UN-RNCE), located in Rio Grande do Norte Province, Brazil, during the implementation of a pipeline leak detection system. That application involved nine multiphase oil pipelines distributed along several production facilities. Because of the emergency after the leakage that polluted the Guanabara bay and due to the two phases and multi phases pipelines characteristics, the UN-RNCE decided to apply the Pressure Point Analysis (PPA) technology in order to detect leakages. It is a statistical method for leak detection e uses a very simple instrumentation which facilitates the installation and maintenance. However, in order to get the best performance of the system, it is necessary to know thoroughly the whole process and have a fast and reliable SCADA system for long distance communication. Finally it will be shown the test results, the recommendations to ...
2003-07-01
Oscillation diagnosis of steam turbines; Schwingungsdiagnose bei Dampfturbosaetzen
Energy Technology Data Exchange (ETDEWEB)
Modern oscillation- and analysis systems are often mentioned in the context of oscillation diagnosis which implies that this is a method of establishing the causes of the mechanical changes that cause the unwanted oscillation. Experience shows, however, that oscillation monitoring instruments can merely indicate oscillation symptoms at an early point in time. These findings must be interpreted in a machine-specific way and seen in the context of previous developments in order to establish the mechanical root cause of the matter. A 1000 MVA-generator shows that conventional oscillation measuring systems may also serve for diagnostic purposes within certain limits.(orig.) [German] Im Zusammenhang mit modernen Schwingungsmess- und Analysensystemen wird haeufig der Begriff der Schwingungsdiagnose verwandt und inpliziert, damit auch die Ursache von mechanischen Veraenderungen finden zu koennen, welche das beanstandete Schwingungsverhalten ...
1998-07-01
On the application of Allan variance method for Ring Laser Gyro performance characterization
Energy Technology Data Exchange (ETDEWEB)
This report describes the method of Allan variance and its application to the characterization of a Ring Laser Gyro`s (RLG) performance. Allan variance, a time domain analysis technique, is an accepted IEEE standard for gyro specifications. The method was initially developed by David Allan of the National Bureau of Standards to quantify the error statistics of a Cesium beam frequency standard employed as the US Frequency Standards in 1960`s. The method can, in general, be applied to analyze the error characteristics of any precision measurement instrument. The key attribute of the method is that it allows for a finer, easier characterization and identification of error sources and their contribution to the overall noise statistics. This report presents an overview of the method, explains the relationship between Allan variance and power spectral density distribution of underlying noise sources, describes the batch and recursive implementation ...
1993-10-15
Observing Evolution in the Supergranular Length Scale During Periods of Low Solar Activity
We present the initial results of an observational study into the variation of the dominant length-scale of quiet solar emission: supergranulation. This length-scale reflects the radiative energy in the plasma of the upper solar chromosphere and transition region at the magnetic network boundaries forming as a result of the relentless interaction of magnetic fields and convective motions of the Sun's interior. We demonstrate that a net difference of ~0.5Mm in the supergranular emission length-scale occurs when comparing observations cycle 22/23 and cycle 23/24 minima. This variation in scale is reproduced in the datasets of multiple space- and ground-based instruments and using different diagnostic measures. By means of extension, we consider the variation of the supergranular length-scale over multiple solar minima by analyzing a subset of the Mt Wilson Solar Observatory (MWO) Ca II K image record. The observations and analysis presented ...
2011-01-01
Multiple-element eddy current probes for enhanced inspection
Energy Technology Data Exchange (ETDEWEB)
Eddy current inspection methods are widely used for the nondestructive evaluation (NDE) of tubular products. Specifically, the sensors and instrumentation are designed to detect and characterize changes in a material's electrical and magnetic properties produced by the presence of discontinuities. A recent major enhancement in eddy current inspection technology has been the development of computer interfacing for data collection, analysis, and display. This breakthrough has led to multiple-frequency testing, eddy current imaging, and automated data interpretation systems that significantly enhance both capabilities and reliability of the eddy current inspection. In addition to the clear advantages in data processing, computer interfacing also permits the design and creation of unique sensors that further enhance eddy current inspection capabilities. Perhaps the most promising area of computer interactive probe design is multiple ...
1993-07-01
Energy Technology Data Exchange (ETDEWEB)
Recently there has been much concern with the ability of plants to uptake heavy metals from their surroundings. With the development of instrumental techniques with low detection limits such as inductively coupled plasma-mass spectrometry (ICP-MS), attention is shifting toward achieving faster and more elegant ways of oxidizing the organic material inherent in environmental samples. Closed-vessel microwave dissolution was compared with conventional methods for the determination of concentrations of cerium, samarium, europium, terbium, uranium and thorium in a series of samples from the National Institute of Standards and Technology and from fields in Idaho. The ICP-MS technique exhibited detection limits in parts-per-trillion and linear calibration plots over three orders of magnitude for the elements under study. The results obtained by using nitric acid and hydrogen peroxide in a microwave digestion system for the analysis of reference ...
1997-08-01
MTX diagnostic and timing system for free-electron laser heating experiments
International Nuclear Information System (INIS)
In the microwave tokamak experiment (MTX) program, we are concentrating on experiments using intense, free-electron laser (FEL) generated microwave pulses. In initial FEL experiments, several diagnostic instruments were operated during injection of microwave pulses with peak powers to 0.2 GW at durations of 10 ns. Fixed and spatially scanning microwave detectors and receivers and a 48-element calorimeter on the inside wall of MTX diagnosed the GW-level FEL microwave pulses. With these diagnostics, linear-wave absorption and efficiencies of transmission through the quasi-optical transport system were studied. In addition, several radially resolved measurements of plasma density, temperature, and emission were made during FEL injection and were used in the analysis of microwave absorption data. A timing system, slaved to the FEL pulse arrival time, is capable of accuracy to a few nanoseconds in order to allow measurement of heating effects on the ...
Laboratory directed research and development program, FY 1996
Energy Technology Data Exchange (ETDEWEB)
The Ernest Orlando Lawrence Berkeley National Laboratory (Berkeley Lab) Laboratory Directed Research and Development Program FY 1996 report is compiled from annual reports submitted by principal investigators following the close of the fiscal year. This report describes the projects supported and summarizes their accomplishments. It constitutes a part of the Laboratory Directed Research and Development (LDRD) program planning and documentation process that includes an annual planning cycle, projection selection, implementation, and review. The Berkeley Lab LDRD program is a critical tool for directing the Laboratory`s forefront scientific research capabilities toward vital, excellent, and emerging scientific challenges. The program provides the resources for Berkeley Lab scientists to make rapid and significant contributions to critical national science and technology problems. The LDRD program also advances the Laboratory`s core competencies, foundations, and scientific capability, ...
1997-02-01
In-pile measurements of fuel rod deformation and verification of the finite element model FEMAXI
International Nuclear Information System (INIS)
For safety evaluations and licensing procedures, fuel rod performance is predicted through model calculations. Due to the complexity of fuel rod performance and the insufficient availability of experimental data, such calculations necessarily reflect inaccuracies and conservatism. For verification and development of more realistic models and submodels, acquisition of reliable on-line data on fuel rod performance characteristics is imperative. The present paper describes the instruments and equipment applied in the Halden Reactor for on-line measurements of fuel rod and assembly power and power distribution, and fuel rod axial and diameter deformation. Recent results from evaluation of such fuel rod deformation measurements, covering fuel rods with different designs, subjected to various modes of operation, including startup ramps, steady state, and power shock, are presented. It is also shown how these data are used for verification and development of the ...
1976-09-13
Growth and characterisation of electrodeposited ZnO thin films
Energy Technology Data Exchange (ETDEWEB)
The electrochemical method has been used to deposit zinc oxide (ZnO) thin films from aqueous zinc nitrate solution at 80 deg. C onto fluorine doped tin oxide (FTO) coated glass substrates. ZnO thin films were grown between - 0.900 and - 1.025 V vs Ag/AgCl as established by voltammogram. Characterisation of ZnO films was carried out for both as-deposited and annealed films in order to study the effect of annealing. Structural analysis of the ZnO films was performed using X-ray diffraction, which showed polycrystalline films of hexagonal phase with (002) preferential orientation. Atomic force microscopy was used to study the surface morphology. Optical studies identified the bandgap to be {approx} 3.20 eV and refractive index to 2.35. The photoelectrochemical cell signal indicated that the films had n-type electrical conductivity and current-voltage measurements showed the glass/FTO/ZnO/Au devices exhibit rectifying properties. The thickness of the ZnO films was ...
2008-04-30
Evaluation of Mechanical Properties and Microstructure in Ion-Irradiated Surface Layer
Target vessel materials used in spallation neutron source will be exposed to proton and neutron irradiation and mercury immersion environments. In order to evaluate the surface degradation of the vessel candidate materials due to such environment, the triple-ion beam irradiation taking the spallation reaction into account and mercury immersion tests were carried out. Mechanical properties of the gradient surface layer were evaluated by the inverse analysis with multi-layer model that considers distribution of surface characteristic was applied to the load and depth curves measured by using the instrumented indentation machine. Transmission electron microscopic observations were performed to evaluate the changes of microstructure in irradiated surface layer using focused ion-beam cut micro-specimen. The mechanical properties distributions in the surface layer were evaluated quantitatively and the changes in microstructures were correspondent to ...
2005-01-01
Energy Technology Data Exchange (ETDEWEB)
A C{sub 60} {sup +} primary ion source has been coupled to an ion microscope secondary ion mass spectrometry (SIMS) instrument to examine sputtering of silicon with an emphasis on possible application of C{sub 60} {sup +} depth profiling for high depth resolution SIMS analysis of silicon semiconductor materials. Unexpectedly, C{sub 60} {sup +} SIMS depth profiling of silicon was found to be complicated by the deposition of an amorphous carbon layer which buries the silicon substrate. Sputtering of the silicon was observed only at the highest accessible beam energies (14.5 keV impact) or by using oxygen backfilling. C{sub 60} {sup +} SIMS depth profiling of As delta-doped test samples at 14.5 keV demonstrated a substantial (factor of 5) degradation in depth resolution compared to Cs{sup +} SIMS depth profiling. This degradation is thought to result from the formation of an unusual platelet-like grain structure on the SIMS crater bottoms. Other ...
2006-07-30
Cross flow boiling in tube bundles
This report contains two main subjects. One is the newly started investigation of cross flow boiling in tube bundles. The heat transfer information at this condition is of significant importance to horizontal steam generator design. The other one is the continuation of the research on boiling heat transfer in confined spaces. The research on cross flow boiling in tube bundles has been started. The Freon loop has been modified for higher flow and higher two phase quality. The test section design is finished and is under fabrication presently. The new instrumentation system is also established. The test matrix has been planned. The research on boiling in confined spaces proceeds steadily. This problem is of great importance to the boiling induced corrosion in the steam generator crevices between the tube and the support plate. In the report of 1981, detailed results were presented for analysis of single phase flow, two phase flow, and dryout in ...
1982-10-01
Energy Technology Data Exchange (ETDEWEB)
In this report, the descriptions of the DIVA test facility and those test matrixes are presented. The test sections simulate the downcomer annulus of DVI system with various scalling methodologies. The UPTF one has 1/7.5 scale and the APR-1400 test sections are reduced in 1/7 scale and 1/5 scale respectively. Also, the instrumentations, measuring methods are described. The major measuring parameters are ECC injection rate, air injection rate, bypass fraction, system pressure and so on. And finally, the operation procedure and experimental steps are introduced. From the DIVA tests, the multi-dimensional behaviors of two-phase flow in the downcomer during the reflood phase can be investigated using a transparent test facility. Also comparing the experimental data which are performed in various scale downcomer, it is expected that some criteria of scalling methodology proper to the DVI system can be derived. 10 refs., 19 figs., 10 tabs. (Author)
2002-03-01
Application of low-resolution Raman spectroscopy for the analysis of oxidized olive oil
British Library Electronic Table of Contents (United Kingdom)
The aim of this study was to evaluate the potential of low-resolution Raman spectroscopy for monitoring the oxidation status of olive oil. Primary and secondary oxidation parameters such as peroxide value, K"2"3"2 and K"2"7"0 were studied. Low-resolution Raman spectra ranging from 200 to 2700 cm^-^1 in a set of 126 oxidized and virgin olive oil samples were collected directly using a probe. Partial Least Squares was used to calibrate the Raman instrument for the different targeted parameters. The performance of the models was determined by using validation sets, and the best results obtained were: R^2 = 0.91, RMSEP = 2.57 for the peroxide value content; R^2 = 0.88, RMSEP = 0.37 for K"2"3"2; and R^2 = 0.90, RMSEP = 0.08 for K"2"7"0. These results demonstrated that low-resolution Raman spect...
2011-01-01
An assessment of energy options for a remote first nation community. Paper no. IGEC-1-055
International Nuclear Information System (INIS)
Development of renewable energy systems for remote communities is gaining interest among government, utilities, NGOs and the communities themselves as a means of improving lifestyles of community members and showcasing renewable energy systems. The Huu-ay-aht First Nation, whose traditional territory is located on the west side of Vancouver Island in British Columbia, is a community which has energy related problems and energy related opportunities. The objective of this study is to assess possible energy options for the Huu-ay-aht First Nation traditional territory. Current and future energy services within the territory were used as the starting point for developing energy system options. Extensive consultation with community members was instrumental in clearly defining the objectives of the study and understanding the territory's energy demand. The energy demand assessment included an estimation of the electric, heating and transportation loads in the community, ...
2005-06-12
Development of calibration facility for radiation protection monitoring instruments
International Nuclear Information System (INIS)
Exposure control at the operating Nuclear Power Station is a major concern. The challenging task of meeting the International standards in the field of radiation protection is the calibration of the radiation monitoring instruments and interpretation of personnel and area monitoring results. Correct interpretation is based on accurate calibration of radiation measuring instruments. The reliability and accuracy of the measurements are also partly based on the procedures applied in calibration. Inadequate calibration can cause large errors in dose estimation in complete dose rate range and energy range. Semiautomatic calibration facility established at TAPS 3 and 4 for radiation monitoring instruments. Objective of calibration facility is (a) Ensure instruments are working properly (b) calibration adjustment and (c) in case without calibration adjustment to reveal the error involved. The calibration ...
2008-11-19
Development of 40m SANS and Its Utilization Techniques
Energy Technology Data Exchange (ETDEWEB)
Small angle neutron scattering (SANS) has been a very powerful tool to study nanoscale (1-100 nm) bulk structures in various materials such as polymer, self assembled materials, nano-porous materials, nano-magnetic materials, metal and ceramics. Understanding the importance of the SANS instrument, the 8m SANS instrument was installed at the CN beam port of HANARO in 2001. However, without having a cold neutron source, the beam intensity is fairly low and the Q-range is rather limited due to short instrument length. In July 1, 2003, therefore, the HANARO cold neutron research facility project was launched and a state of the art 40m SANS instrument was selected as top-priority instrument. The development of the 40m SANS instrument was completed as a joint project between Korea Advanced Institute of Science and Technology and the HANARO in 2010. Here, we report the ...
2010-06-15
Energy Technology Data Exchange (ETDEWEB)
This paper presents an overview of research conducted with the support of the Australian Institute of Nuclear Science and Engineering, at the University of Melbourne, School of Earth Sciences, Radiochemical Neutron Activation Laboratory. The primary objective of this research is to realize the high potential of the platinum group elements (PGE) and gold to the solution of petrogenetic problems, the study of magma generation and magmatic processes in mafic/ultramafic rock suites, as tracers in hydrothermal ore formation. The PGEs (Os, Ru, Ir, Pt, Pd and Rh) are among the least abundant of all elements on earth with unique properties such as high melting points, high electrical and thermal conductivity, high density, strength and toughness as alloys. They exhibit both siderophile and chalcophile characteristics and are valuable tools in providing information about magmatic processes, in particular S-saturation, as well as crystal fractionation trends. Two distinct groups of PGEs are ...
1996-12-31
Background: Accountability demands are increasingly pushing school leaders to explore more data and do more sophisticated analyses. Data-driven decision making (DDDM) has become an emerging field of practice for school leadership and a central focus of education policy and practice. Purpose: This study examined principals' DDDM practices and identified the factors influencing DDDM using the theoretical frame of information use environments. Participants: Participants were 183 public high school principals in a Midwestern state. Research Design: The research design was cross-sectional survey research. Data Collection and Analysis: Survey instruments were developed and administered to principals. Structural equation modeling was conducted to determine what factors significantly affect principals' DDDM practices in different leadership dimensions. Findings: Principals used data more frequently in instructional and organization operational ...
2007-12-01
RESEARCH IN ACTIVATION ANALYSIS. Quarterly Progress Report, April-August 1962
The experimental work completed thus far in the areas of rapid radiochemical separations and metastable isomeric states is summarized. Activation analyses were made in samples of ore materials and metals using rapid radiochemical separations to isolate short-lived radioactive isotopes such as 3.77-min V/sup 52/ and 14.6-min Mo/sup 101/. The analytical results obtained were compared to the results obtained from standard chemical and instrumental analytical methods and, where possible, to activation analysis results obtained from longer-lived isotopes of the same element. Further work is in progress to improve the procedures, to evaluate the reproducibility and accuracy of the methods, and to evaluate their usefulness on a wide variety of sample matrices. The research on short-lived metastable isomers showed that 1.7-min W/sup 185m/ is not produced in sufficiently high yield for the development of a supplementary ...
1962-09-19
Minerals and trace elements determination in diets by neutron activation analysis
International Nuclear Information System (INIS)
In the present study 12 diets, each one consisting of a pool of seven day diets, composed by four meals: breakfast, lunch, dinner and snack, adequate in energy and macro nutrients according to the RDA (Recommended Daily Allowance) recommendations, were elaborated and offered to a group of 12 men (19-42 years). The diets were collected by duplicate portion technique and dried by two different processes: freeze drying and 60 deg C ventilated oven drying. In the total, 24 diets were analyzed. The content of some minerals and trace elements (Ca, Fe, Mg, Mn, Na, Se and Zn) were determined by Instrumental Neutron Activation Analysis. The validation of methodology was made by analysis of the reference materials Typical Diet (NIST SRM 1548"a), Orchard Leaves (NIST SRM 1541) and Peach Leaves (NIST SRM 1547). The results observed by two different drying processes used were statistically compared by test T of Student. It was possible ...
2002-08-11
Energy Technology Data Exchange (ETDEWEB)
This paper describes the methods and systems as utilized in an integrated experimental thermohydraulic/mechanics analysis test program on waterhammer pressure pulses within a revised feedwater sparger of a Loviisa generation VVER-440-type reactor. This program was carried out in two stages: (1) measurements with a strictly limited set of operating parameters at Loviisa NPP, and (2) measurements with the full set of operating parameters on a test article simulating the revised feedwater sparger. The experiments at Loviisa NPS served as an invaluable source of information on the nature of waterhammer pressure pulses and structural responses. These tests thus helped to set the objectives and formulate the concept for series of tests on a test article to study the water hammer phenomena. The heavily instrumented full size test article of a steam generator feedwater sparger was placed within a pressure vessel simulating the steam generator. The ...
1997-12-31
Calibration free laser-induced breakdown spectroscopy of oxide materials
Energy Technology Data Exchange (ETDEWEB)
The quantitative determination of oxide concentration by laser-induced breakdown spectroscopy is relevant in various fields of applications (e.g.: analysis of ores, concrete, slag). Calibration free laser-induced breakdown spectroscopy and the multivariate calibration are among the methods employed for quantitative concentration analysis of complex materials. We measured the intensity of neutral and ionized atomic emission lines of oxide materials by laser-induced breakdown spectroscopy and we modified the calibration free laser-induced breakdown spectroscopy method to increase the accuracy. The concentration of oxides was obtained by using stoichiometric relations. Sample materials were prepared from oxide powder (Fe{sub 2}O{sub 3}, MgO, CaO) by mixing and pressing. The concentration was 9.8-33.3 wt.% Fe{sub 2}O{sub 3}, 7.6-33.3 wt.% MgO and 33.3-81.2 wt.% CaO for different samples. Nd:YAG laser (wavelength 1064 nm, pulse duration {approx} 6 ...
2010-08-15
Energy Technology Data Exchange (ETDEWEB)
The pharmacological properties of medicinal plants have been related to the presence of organic compounds, however elements are also known to have an important participation in the active compounds constitution process. In this study, instrumental neutron activation analysis (INAA) was applied to determine elements in leaves of Casearia obliqua medicinal plant collected at two different locations in the Atlantic Forest, Brazil, SP. Soil samples collected from where this plant was grown were also analyzed in order to verify if there is a correlation between the elements present in soils and plant leaves. Br, Ca, Cl, Co, Cr, Cs, Fe, K, La, Mn, Na, Rb, Sb, Sc and Zn were determined in C. obliqua leaves and the elements As, Ca, Ce, Eu, Fe, Hf, La, Lu, Nd, Rb, Sc, Sm, Tb, Th, U and Zn in soils. Soil samples collected from two different locations presented similar concentrations for most elements. Likewise, C. obliqua leaves collected from the two ...
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
Three test instruments are being evaluated to determine the feasibility of using photoacoustic technology for measuring unburned carbon in fly ash. The first test instrument is a single microwave frequency system previously constructed to measure photoacoustic signals in an off-line configuration. A second off-line instrument was constructed based in part on lessons learned with the first instrument, but which also expands the capabilities of the first instrument. Improvements include a control loop to allow more constant microwave power output and an ability to operate over a range of microwave frequencies. The third instrument, the on-line version of the fly ash monitor, has been designed, constructed, and initial efficiency tests have been conducted on the monitor's electrical components. This quarter focused on improving the signal strength of the ...
2004-07-01
Long-term preventive maintenance of instrumentation control equipment for PWR plants
International Nuclear Information System (INIS)
Since the PWR plants in Japan have been operated more than 30 years, main instrumentation control equipment of analog systems has been renewed to digital control systems. Renewal works had to be done in short period within periodical inspection term and for several facilities. The Mitsubishi LTD group had been provided with these market needs by its digital control system (MELTAC-NplusR 3) applicable to main instrumentation control equipment for primary and secondary systems and had already finished the renewal for practical plants. (T. Tanaka)
2006-02-01
Energy Technology Data Exchange (ETDEWEB)
With increasing liberalization of the energy sector, German suppliers of line-transmitted energy find themselves in an utterly changed sales environment, forcing companies and utilities to elaborate for the first time management policies and strategies that will ensure loyalty of their present customers, and help to solicit new customers. The article here explains some major terms and instruments used in designing key-account management strategies, as well as general procedures for suitability assessment. (orig/CB)
1999-06-01
Basic Design Report of DC-TOF Inelastic Neutron Spectrometer
Energy Technology Data Exchange (ETDEWEB)
We made Basic designs of neutron guide, choppers, and detectors in order to optimize the design parameters of DC-TOF to be built in the HANARO Cold Neutron Guide Hall. In addition, we calculated the expected performance of DC-TOF using Monte Carlo simulations and evaluated the properties of neutron beam. Based on the results we obtained, we have compared the expected performance of the DC-TOF with those of existing instruments overseas. In conclusion, we believe that we will be able to construct the DC-TOF at HANARO as one of the best instruments of its kinds and it will become an invaluable instrument to researchers in the related field.
2006-04-15
Public speaking is the most commonly reported fearful social situation. Although a number of contemporary theories emphasize the importance of cognitive processes in social anxiety, there is no instrument available to assess fearful thoughts experienced during public speaking. The Self-Statements During Public Speaking (SSPS) scale is a 10-item questionnaire consisting of two 5-item subscales, the "Positive Self-Statements" (SSPS-P) and the "Negative Self-Statements" subscale (SSPS-N). Four studies report on the development and the preliminary psychometric properties of this instrument. PMID:16763666
2000-01-01
Energy Technology Data Exchange (ETDEWEB)
This thesis presents the work achieved to instrument the ATLAS software framework, ATHENA, with a library of tools and utensils for the physics analysis as well as the extraction of the jet energy scale using physics events (in-situ calibration). The software part presents the various components of the ATHENA framework which handles the simulated and reconstructed data flow as well as the different stages of this process, before and during the data taking. The building of a library of tools easing the reconstruction of physics objects, their association with Monte-Carlo particles and their API is then explained. The need for common language and collaboration-wide utensils is emphasised as it allows to share the workload of validating these tools and to get reproducible physics results. The analysis part deals with the implementation of a light jet energy scale calibration algorithm within the C++ framework. This calibration ...
2006-07-01
Energy Technology Data Exchange (ETDEWEB)
The US Department of Energy (DOE) Mixed Waste Integrated Program (MWIP) has as one of its tasks the identification of a decision methodology and key decision criteria for the selection methodology. The aim of a multicriteria analysis is to provide an instrument for a systematic evaluation of distinct alternative projects. Determination of this methodology will clarify (1) the factors used to evaluate these alternatives, (2) the evaluator`s view of the importance of the factors, and (3) the relative value of each alternative. The selected methodology must consider the Comprehensive Environmental Response Compensation and Liability Act (CERCLA) decision-making criteria for application to the analysis technology subsystems developed by the DOE Office of Technology Development. This report contains a compilation of several decision methodologies developed in various national laboratories, institutions, and universities. The ...
1993-11-01
Discrepancies in molar extinction coefficients of Fe"3"+ in Fricke dosimetry
International Nuclear Information System (INIS)
Values of the chemical yield, G, and of the molar extinction coefficient, epsilon, for Fricke dosimetry, have been recommended by ICRU. For epsilon, the value in ICRU Reports 17 and 21, 2205 1.mol"-"1.cm"-"1, based on an analysis of 83 reported values. It was suggested that, where neither a careful wavelength calibration nor absorbance linearity checks had been performed, a standard error of 1.5% should be assumed; otherwise 0.15% could be accepted. Alternatively, the accuracy in applying this chemical dose meter was considered improved if there was an independent determination of epsilon with the same spectrophotometer as was used for the determination of the optical density of irradiated Fricke solution. The accuracy claimed for both methods remains questionable, since no complete argumentation could be given for the differences of up to 13% in the published values. Taking into account the discussion of the sources of error by Bryant, Broszkiewicz and Ellis, we ...
1977-12-09
The Goddard Library - Goddard Projects Directory - NASA
Oct 2, 2007 ... Other payloads included the Orbiter Experiments Autonomous Supporting Instrumentation System-1 (OASIS-1), a cooling system designed for ...
The Confidence in Diabetes Self-Care Scale
UK PubMed Central (United Kingdom)
OBJECTIVETo examine psychometric properties of the Confidence in Diabetes Self-Care (CIDS) scale, a newly developed instrument assessing diabetes-specific self-efficacy...Full Text Available
2003-03-01
The 2011 AusGO/AAO Observational Techniques Workshop
Applying for AAO scheduled time Applying for AAT service time Applying for Gemini Time Travel and Accommodation AAT Schedule UKST Schedule Instrument capabilities and...
2011-10-15
Superterrorism and the Military Instrument of Power
... Defense. ... 6 Specific restrictions are outlined in US Signals Intelligence Directive (USSID) 18 and DoD Regulation 5240.1-R. 7 House ...
1998-04-01
Suicidality: Prospective Assessment of Occurrence in Clinical ...
... was associated with at least some 360 intent to ... herself, at least to 366 some degree, can be ... As prospective assessment instruments for suicidality are created ...
Remote Sensor Systems for Unmanned Planetary Missions
instrument is shown in Figure 4-9 The incoming radiation is focused onto ...... An early rocket-borne ultraviolet spectrometer of the Ebert type by ...
Quality of Surgical Instruments
UK PubMed Central (United Kingdom)
INTRODUCTIONMany surgeons will have encountered the scissors that would not cut, and the artery clip that comes off in a deep difficult location, but it would be reasonable to assume...Full Text Available
2006-07-01
The US National Aeronautics and Space Administration (NASA) has been monitoring the ozone layer from space using optical remote sensing techniques since 1970. With concern over catalytic destruction of ozone (mid-1970s) and the development of the Antarctic ozone hole (mid-1980s), long term ozone monitoring has become the primary focus of NASA's series of ozone measuring instruments. A series of TOMS (Total Ozone Mapping Spectrometer) and SBUV (Solar Backscatter Ultraviolet) instruments has produced a nearly continuous record of global ozone from 1979 to the present. These instruments infer ozone by measuring sunlight backscattered from the atmosphere in the ultraviolet through differential absorption. These measurements have documented a 15 Dobson Unit drop in global average ozone since 1980, and the declines in ozone in the antarctic each October have been far more dramatic. Instruments that measure ...
2002-01-01
National Advisory Committee for Aeronautics 1952 - NASA Technical ...
By Charles E. Watkins. 2458. An Instrument Employing a Coronal Discharge for ..... Grover, W. S. Hyler, and L. R. Jackson. 2640. Interaction of Column and ...
Molecular spectroscopy and planetary atmospheres
Energy Technology Data Exchange (ETDEWEB)
With the improvements accomplished during the past 15 years in detection techniques and instrumentation and with the opening of space exploration, molecular spectroscopy has become a very efficient way to probe planetary atmospheres.
1984-01-01
Medical problems affecting musicians.
UK PubMed Central (United Kingdom)
The physical demands of performing on musical instruments can cause pain, sensory loss, and lack of coordination. Five cases illustrate common problems. Knowledge of the interaction between the technique...Full Text Available
1995-12-01
MASTER - NASA Technical Reports Server
Reactor Effluent Purification System. 7.4.3. Filter Reactor Outlet Gas (FROG). 7.5. Instrumentation and Controls for NSS Tests ...
ground strike hazards 3) Advancements in the initialization of numerical weather prediction models through better identification of deep convection 4) Improved routing of...
2011-08-27
Development of in-vessel reflood instrumentation at ORNL
International Nuclear Information System (INIS)
A program under the sponsorship of the United States Nuclear Regulatory Commission was intiated at the Oak Ridge National Laboratory (ORNL) in late 1977. The program, Advanced Instrumentation for Reflood Studies (AIRS), is charged with developing instrumentation for measurement of in-vessel fluid phenomena in pressurized water reactor reflood facilities. The goal of the ORNL program is to develop techniques and systems for measuring fluid flow in-core, deentrainment in the upper plenum and liquid fallback from the upper plenum into the core. A large portion of the development at ORNL is devoted to the impedance probes for measurement of two-phase flow velocities and void fractions. Film probe development at ORNL is limited to adapting the present techniques to the environment of a reflood facility. As the development progresses on all the measurement techniques, ORNL will fabricate and supply instrument systems to the ...
2004-09-06
Canal-centering ability: An endodontic challenge
UK PubMed Central (United Kingdom)
During instrumentation of the root canal, it is important to develop a continuously tapered form and to maintain the original shape and position of the apical foramen. However, the presence of curvatures...Full Text Available
2009-01-01
An instrumented cylinder measuring pinch force and orientation
UK PubMed Central (United Kingdom)
BackgroundThe function of a cylinder allowing simultaneous measurements of the opposition axis of the index finger and thumb of the hand and the magnitude of pinch force is described.Full Text Available
AeroSpace Information for a Changing World - NASA Technical ...
Mar 1, 2011 ... Currently there is no compact, portable and real time neutron detector instrumentation available for use inside spacecraft or on planetary ...
The Preliminary GAMMA Code Thermal hydraulic Analysis for the Steady State of HTR-10 Initial Core
Energy Technology Data Exchange (ETDEWEB)
This report describes the preliminary thermalhydraulic analysis of HTR-10 steady state full power initial core to provide a benchmark calculation of VHTGR(Very High-Temperature Gas-Cooled Reactors) safety analysis code of GAMMA(GAs Multicomponent Mixture Analysis). The input data of GAMMA code are produced for the models of fluid block, wall block, radiation heat transfer and each component material properties in HTR-10 reactor. The temperature and flow distributions of HTR-10 steady state 10 MW{sub th} full power initial core are calculated by GAMMA code with boundary conditions of total reactor inlet flow rate of 4.32 kg/s, inlet temperature of 250 .deg. C, inlet pressure of 3 MPa, outlet pressure of 2.992 MPa and the fixed temperature at RCCS water cooling tube of 50 .deg C. The calculation results are compared with the measured solid material temperatures at 22 fixed instrumentation positions in ...
2006-07-15
International Nuclear Information System (INIS)
The High Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory is one of the world's most powerful research reactors. In 1996, one year after the demise of the Advanced Neutron Source Project, the U.S. Department of Energy embarked on an aggressive program to upgrade the neutron scattering facilities at the HFIR. These upgrades, which are now in progress, include the installation of larger beam tubes, a high-performance hydrogen cold source, and additional neutron guides and neutron scattering instruments. An extensive analysis effort was performed over the past 4 yr to support the design of the modified beamlines and new user facilities and to assess the impact of the upgrades on the integrity of the existing reactor system. The results of three of these analyses are summarized here. Specifically, results are presented for analyses related to the design of the new cold neutron source (CNS), the assessment of beam tube changes on ...
2001-06-17
Environmental trace gas analysis by proton-transfer-reaction mass spectrometry (PTR-MS)
International Nuclear Information System (INIS)
The work presented here demonstrates the ability of proton-transfer-reaction mass spectrometry (PTR-MS) to perform fast-response measurements of volatile organic compounds (VOCs) (including methanol, acetonitrile, acetaldehyde, acetone, PAN-type compounds, alpha- and beta-pinene, nopinone and pinonaldehyde) at the pptv level and its versatile applicability in the field of environmental trace gas analysis. Laboratory and field experiments including various calibration techniques and intercomparisons with other measurement techniques such as gas chromatography, atmospheric pressure chemical ionization and Fourier transformation infrared spectroscopy were performed providing a first characterization of the PTR-MS instrument performance (sensitivity, detection limit, precision, accuracy). Typically a detection limit (S/N=2) of 50 pptv for a 10 s signal integration time, a precision of 5 % and an accuracy in the range between 10 and 25 % were ...
Energy Technology Data Exchange (ETDEWEB)
It is necessary that reclaimed land from open pit mining operations has completely settled before it can be returned to the public domain. This paper reports on instrumentation installed to observe settlement of the spoil and behaviour of a prototype foundation on reclaimed land in Alberta, Canada. 6 refs., 7 figs.
1987-11-01
Pollution control instrumentation for oil and effluents
Energy Technology Data Exchange (ETDEWEB)
This book provides discusses recent developments in oil pollution control instrumentation. Some of the topics covered are as follows: 1. Technical requirements of the IMCO International Performance and Test Specification A393x concerning oil content meters; and 2. Oil in water detection; and 3. Methods for the disposal of recovered oil and oily sludge; and 4. Oil content monitoring at ballast water treatment facilities and offshore production platforms.
1986-01-01
Overview of IAEA year 2000 activities in the Department of Safeguards
International Nuclear Information System (INIS)
The IAEA Department of Safeguards established a project in 1996 for the year 2000 (Y2K) conversion activities. This project covered assessment, conversion and testing of the software applications, instrument evaluation software, embedded systems and Personal Computer (PC) hardware attached to various equipment. Significant progress has been made in converting the applications and instruments to be year 2000 compliant. At the same time Member states have made an effort as well in converting the systems used jointly at the facilities
1999-02-01
Measuring equipment for the monitoring of air pollution control - a market review
Energy Technology Data Exchange (ETDEWEB)
The paper abstracted gives a tabular survey of the suppliers and applications of measuring equipment. Equipment is available for the following fields of application: Continuous measuring instruments for stationary operation, laboratory equipment for sampling and hand equipment for mobile measurement, sampling equipment for examining emissions and gases, detectors, storage and evaluation equipment and meteorological instruments. (PW).
1986-01-01
Measurement of audible noise from transmission lines
Energy Technology Data Exchange (ETDEWEB)
The audible noise produced by corona on high-voltage transmission lines has several characteristics that differentiate it from other community noises. Transmission line noise is quite broadband and has a significant high frequency content. Special instrumentation designed to measure this type of noise pollution is described. All measuring systems have the same three basic elements: a transducer, a processing device, and an output device. Recorders, microphone devices, frequency analyzers, and meteorological instrumentation are discussed.
1981-03-01
Instrumentation is the key to advanced mining techniques
Energy Technology Data Exchange (ETDEWEB)
To achieve the high degree of management control and operational efficiency necessary for new undertakings, there will be a heavy dependence on schemes for the remote control and monitoring of all mine activities both on the surface and underground, plus the provision of information on operations, plant and equipment. This will all need to be supervised from a central control point on the colliery surface. A survey of recently introduced instrumentation systems makes it clear that British manufacturers already have made major advances in the field of automation, and new equipment constantly comes on to the market.
1980-04-01
Energy Technology Data Exchange (ETDEWEB)
In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).
1993-12-01
Development of laser-ion beam photodissociation methods
Energy Technology Data Exchange (ETDEWEB)
During this report period our research efforts have concentrated on studies of the dissociation reactions of model peptides and other biologically important molecules. In addition, a considerable amount of research effort has been directed toward improving the apparatus used for laser-ion beam photodissociation. The instrumental improvements include some changes on the original apparatus, but most of this effort involved designing a second generation laser-ion beam photodissociation instrument.
1990-08-01
Developing DB system of piping reliability
Energy Technology Data Exchange (ETDEWEB)
Developing DB system of piping reliability including the population data and service history of damaged piping for pilot power plant. Total weld counts of shop welds, field welds and welds for measuring instruments for 14 systems of Kori unit 3. Total weld counts of shop welds, field welds and welds for measuring instruments for 12 systems of Wolsung unit 2.
2005-03-15
DIPAC 2005 7. European workshop on beam diagnostics and instrumentation for particle accelerators
Energy Technology Data Exchange (ETDEWEB)
Accelerators can not be improved without the development of adequate beam instruments and diagnostic tools. This year this statement is particularly right: a lot of contributions are dedicated to beam monitoring and to the design of new beam monitors based on original technologies. This document gathers about 100 contributions.
2005-07-01
Commodity storage valuation: A linear optimization based on traded instruments
British Library Electronic Table of Contents (United Kingdom)
A valuation methodology for commodity storage facilities is proposed. This model utilizes traded instruments to replicate the fundamental derivative components of commodity storage facilities. The methodology is robust to different commodities, physical characteristics, and markets for valuing these types of assets. Two examples using the U. S. natural gas markets are presented.
2006-01-01
An outline of the fuelling machine electrical instrumentation and controls
International Nuclear Information System (INIS)
An outline of the instrumentation and control systems associated with fuelling machines is given. The control systems such as hydraulic system, oil hydraulic system, electric control system and the remote control systems have been discussed in detail. The difference between RAPP and MAPP fuel handling control systems has been explained. A computer based system for the Narora fuel handling control system is also discussed. (S.K.K.).
An instrument for measuring spatial and time characteristics of sea agitation in coastal zones
Energy Technology Data Exchange (ETDEWEB)
Resistive analogous meters for spatial and time characteristics in ocean agitation are most often used in practical oceanography in coastal zones but are based on bridge circuits determined to have shortcomings in their linearity range. This shortcoming is eliminated in the circuit of an instrument developed in an oceanographic laboratory (IMIO, Vana). Principle and block circuits are indicated, and static calibration curves are presented as are the correlative functions in the frequency spectrums obtained with the help of sea agitation recorded at a fixed point and at a depth of 6 meters.
1981-01-01
Accelerated aging speeds test of instrument reliability
International Nuclear Information System (INIS)
Safety-related instrument in nuclear power plants must be checked for reliability over their projected operating life. A method of conducting accelerated aging tests is presentd. It uses the Arrhenius activation energy concept and manipulation of the parameters of the test e.g. by raising test temperature, by relying on a model characterizing the chemical-related reactions of materials.
1982-01-01
Energy Technology Data Exchange (ETDEWEB)
Installation of the electrical equipment at the Barstow Solar Pilot Plant is the concern of this construction package. Technical specifications for power and instrument cables, meteorological instruments, and control cables are defined. The documentation requirements are briefly discussed.
1980-07-01
An ELISA-based high throughput protein truncation test for inherited breast cancer
IntroductionBreast cancer is the most diagnosed and second leading cause of cancer deaths in the U.S. female population. An estimated 5 to 10 percent of all breast cancers are inherited, caused by mutations in the breast cancer susceptibility genes (BRCA1/2). As many as 90% of all mutations are nonsense mutations, causing a truncated polypeptide product. A popular and low cost method of mutation detection has been the protein truncation test (PTT), where target regions of BRCA1/2 are PCR amplified, transcribed/translated in a cell-free protein synthesis system and analyzed for truncated polypeptides by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) and autoradiography. We previously reported a novel High Throughput Solid-Phase PTT (HTS-PTT) based on an enzyme-linked immunosorbent assay (ELISA) format that eliminates the need for radioactivity, SDS-PAGE and subjective interpretation of the results. Here, we report the next generation HTS-PTT using ...
2010-10-04
Using the in situ lift-out technique to prepare TEM specimens on a single-beam FIB instrument
International Nuclear Information System (INIS)
Transmission electron microscope (TEM) specimens are today routinely prepared using focussed ion beam (FIB) instruments. Specifically, the lift-out method has become an increasingly popular technique and involves removing thin cross-sections from site-specific locations and transferring them to a TEM grid. This lift-out process can either be performed ex situ or in situ. The latter is mainly carried out on combined dual-beam FIB and scanning electron microscope (SEM) systems whereas conventional single-beam instruments often are limited to the traditional ex situ method. It is nevertheless desirable to enhance the capabilities of existing single-beam instruments to allow for in situ lift-out preparation to be performed since this technique offers a number of advantages over the older ex situ method. A single-beam FIB instrument was therefore modified to incorporate an in situ micromanipulator fitted ...
2008-08-01
Energy Technology Data Exchange (ETDEWEB)
Pollution abatement measures against impulsive low frequency noises including mine blasting noise require precise measurement of sound waveforms, but no instruments have been designed for that purpose, nor commercially available. This paper describes investigations on such instruments as noise level meters currently available commercially on their instrumental characteristics using indoor experiments and field measurements. The following matters were clarified: An instrument combining a microphone with an amplifier can not determine the response from the measuring system from the respective frequency characteristics alone, and requires a discussion on the overall response from the measuring system. A preferred noise level meter would be an instrument that has the lower limit for the frequency characteristics of the microphone extended to several hertz, and measures noises without ...
1991-11-25
Target Diagnostic Instrument-Based Controls Framework for the National Ignition Facility
Energy Technology Data Exchange (ETDEWEB)
NIF target diagnostics are being developed to observe and measure the extreme physics of targets irradiated by the 192-beam laser. The response time of target materials can be on the order of 100ps--the time it takes light to travel 3 cm--temperatures more than 100 times hotter than the surface of the sun, and pressures that exceed 109 atmospheres. Optical and x-ray diagnostics were developed and fielded to observe and record the results of the first 4-beam experiments at NIF. Hard and soft x-ray spectra were measured, and time-integrated and gated x-ray images of hydrodynamics experiments were recorded. Optical diagnostics recorded backscatter from the target, and VISAR laser velocimetry measurements were taken of laser-shocked target surfaces. Additional diagnostics are being developed and commissioned to observe and diagnose ignition implosions, including various neutron and activation diagnostics. NIF's diagnostics are being developed at LLNL and with collaborators at ...
2007-05-07
Thermal release of volatile fission products from irradiated nuclear fuel
International Nuclear Information System (INIS)
An effective procedure for removing _3H, Xe and Kr from irradiated fuels was demonstrated using Shippingport UO"2 fuel. The release characteristics of _3H, Kr, Xe, and I from irradiated nuclear fuel have been determined as a function of temperature and gaseous environment. Vacuum outgassing and a flowing gas stream have been used to vary the gaseous environment. Vacuum outgassing released about 99% of the _3H and 20% of both Kr and Xe within a 3 h at 1500_0C. Similar results were obtained using a carrier gas of He containing 6% H"2. However, a carrier gas containing only He resulted in the release of approximately 80% of the _3H and 99% of both Kr and Xe. These results indicate that the release of these volatile fission products from irradiated nuclear fuel is a function of the chemical composition of the gaseous environment. The rate of tritium release increased with increasing temperature (1100 to 1500_0C) and with the addition of hydrogen to the gas stream. Using crushed UO"2 fuel ...
The effects of helium on the embrittlement and hardening of boron doped EUROFER97 steels
International Nuclear Information System (INIS)
The role of helium in a process of embrittlement and hardening of RAFM steels was investigated in EUROFER97 based experimental heats, ADS2, ADS3 and ADS4, that were doped with different contents of natural B and the separated 10B-isotope (0.008-0.112 wt.%). The neutron irradiation of the boron doped and the reference RAFM steels was performed in the Petten High Flux Reactor up to 16.3 dpa at different temperatures between 250 and 450 deg. C. The embrittlement behaviour and hardening was investigated by instrumented Charpy-V tests with subsize specimens. Irradiation lead to generation of 84, 432 and 5580 appm He in ADS2, ADS3 and ADS4 steels, respectively. At irradiation temperatures Tirr ? 350 deg. C the boron doped steals show progressive embrittlement and reduction of toughness with increasing helium amount. The analysis of the hardening vs. embrittlement behaviour at Tirr ? 350 deg. C reveals hardening nature of embrittlement for helium ...
2008-12-01
The calibration of sub-Coulomb heavy ion proton transfer reactions
Energy Technology Data Exchange (ETDEWEB)
Measurements were made of the cross sections for the /sup 27/Al(/sup 16/O,/sup 15/N)/sup 28/Si, /sup 89/Y(/sup 15/N,/sup 16/O)/sup 88/Sr and /sup 89/Y(/sup 27/Al,/sup 28/Si)/sup 88/Sr reactions at energies near and below the Coulomb barrier. The first reaction required separate measurements of the transfer to elastic cross section ratio for particular charge states, the charge state distribution for /sup 27/Al and /sup 28/Si ions, and the absolute elastic scattering cross section for the /sup 27/Al + /sup 16/O system. The ratio measurement required the combined use of two relatively new scientific instruments: the momentum filter and the Bragg curve spectrometer. The latter two transfer measurements were performed using the same setup involving surface barrier detectors at backward angles. Additional elastic scattering data for the /sup 15/N + /sup 28/Si, /sup 89/Y + /sup 15/N, /sup 89/Sr + /sup 27/Al, and /sup 88/Sr + /sup 28/Si systems was collected to provide ...
1987-01-01
The paper examines science fiction literature as a product and part of the social consciousness of the modern capitalist world order. This world order is seen as emphasizing science, technology, movement, growth, urbanization, industrialization, complex organization, and progress. The document is organized into two sections. The first section reviews theories of the sociology of knowledge and discusses knowledge as a process of self-production and reproduction of society. Influential theorists include Hegel, Marx, Lukacs, Mannheim, Gramsci, Habermas, and Touraine. Touraine's (1977) dynamic conflict-based systematic theory of society is based on three concepts: historicity, which defines the instruments of society's self-production; the system of historical action which is the totality of social and cultural orientations, by means of which historicity exercises its control of historicity and the system of historical action. The second section discusses science ...
1980-10-01
Radon in soil gas survey in Curitiba (Brazil)
International Nuclear Information System (INIS)
This work describes the radon in soil gas measurements performed during the last two years in cooperation between the Laboratory of Applied Nuclear Physics of the Federal University of Technology (UTFPR), the Nuclear Technology Development Center (CDTN) and the Institute of Radiation Protection and Dosimetry (IRD) from the Brazilian Nuclear Energy Commission (CNEN). Following previously concluded measurements of radon concentration in dwellings and the measurements of 222Rn activity in drinking water collected at artesian bores of Curitiba urban area, present step of activities has been dedicated to measurements of radon concentration in soil gas. Experimental setup was based on the Professional Radon Monitor (ALPHA GUARD) connected to specially developed for such measurements Soil Gas Probe through the air pump and filter system. After the Probe was inserted, the ground has been tamped down around the probe, to prevent air from moving vertically along the outside of the shaft. The ...
2002-10-08
Energy Technology Data Exchange (ETDEWEB)
A non-invasive diagnostic tool that could identify malignancy in situ and in real time would have a major impact on the detection and treatment of cancer. We have developed and are testing early prototypes of an optical biopsy system (OBS) for detection of cancer and other tissue pathologies. The OBS invokes a unique approach to optical diagnosis of tissue pathologies based on the elastic scattering properties, over a wide range of wavelengths, of the microscopic structure of the tissue. The use of elastic scattering as the key to optical tissue diagnostics in the OBS is based on the fact that many tissue pathologies, including a majority of cancer forms, manifest significant architectural changes at the cellular and sub-cellular level. Since the cellular components that cause elastic scattering have dimensions typically on the order of visible to near-IR wavelengths, the elastic (Mie) scattering properties will be strongly wavelength dependent. Thus, morphology and size changes can be ...
1993-08-01
Mercury flow experiments. 3. Simulation test plan under abnormal condition
Energy Technology Data Exchange (ETDEWEB)
Japan Atomic Energy Research Institute (JAERI) and High Energy Accelerator Research Organization (KEK) are promoting construction plan of Material-Life Science Facility, which is consisted of Muon Science Facility and Neutron Scattering Facility, in order to open up the new science fields. The Neutron Scattering Facility will be utilized for advanced fields of Material and Life science using high intensity neutrons generated by the spallation reaction induced by injecting a 1 MW pulsed proton beam onto a mercury target. Design of the spallation mercury target system is in progress to obtain good neutron performance keeping high reliability and safety. The target material is mercury. As a result of the spallation reaction, large amount of radioactive spallation products are to be contained in the mercury. Therefore to establish the safety of the target system, transient behaviors of the system during anticipated events should be well understood. The safety protection system and an ...
2002-02-01
Management of dams for the next Millennium: proceedings of the 1999 Canadian Dam Association
Energy Technology Data Exchange (ETDEWEB)
The meeting featured seven sessions with 18 papers abstracted/indexed therein as follows: keynote address: tailings dams safety - implications for the dam safety community; 1 - design and performance: performance monitoring of dams: are we doing what we should be doing?; tailings dams from the perspective of conventional dam engineering; and design overview of Syncrude's Mildred Lake east toe berm; 2 - design and modelling: use of a 2D model for a dam break study on the ALCAN hydroelectric complex in Quebec; and spillway design implications resulting from changes in rainfall extremes; 3 - risk and dam safety I: closing the gaps in the dam safety guidelines; the reality of life safety consequence classification; and surveillance practices for the next millenium; 4 - risk and dam safety II: quantitative risk-assessment using the capacity-demand analysis; and new guidelines for dam safety classification; 5 - millenium issues: expectations of immortality, dam ...
1999-07-01
Development of a neutron/. gamma. ray radiation monitor
Energy Technology Data Exchange (ETDEWEB)
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/..gamma.. ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time ..gamma.. spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded ..gamma.. spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations using a linearized approximation to the ...
1983-01-01
Development of a neutron/#gamma# ray radiation monitor
International Nuclear Information System (INIS)
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/#gamma# ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time #gamma# spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded #gamma# spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations using a linearized approximation to the electron ...
1983-01-01
Development of a Neutron/gamma Ray Radiation Monitor.
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/gamma ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time gamma spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded gamma spectra created by the photopeak-compton edge combination in the plateau portion of the knee response, correcting equations using a linearized approximation to the electron ...
1983-01-01
The principles of modern pesticide residue chemistry were articulated in the 1950s. Early authors pointed out the advantages of systematizing and standardizing analytical methods for pesticides so that they could be widely practiced and the results could be reproduced from one laboratory to the next. The availability of improved methods has led to a much more complete understanding of pesticide behavior and fate in foods and the environment. Using methods based largely upon gas chromatography (GC) and high-performance liquid chromatography (HPLC) coupled increasingly with mass spectrometry (MS) and MS(n) as the detection tool, residues can be measured at parts per billion levels and below in a variety of food and environmental matrices. Development of efficient extraction and cleanup methods, techniques such as ELISA, efficient sample preparation techniques such as QuEChERS, and automated laboratory and field instrumentation has also contributed to the tools ...
2011-04-07
Energy Technology Data Exchange (ETDEWEB)
In the investigations reported here, a helium-jet/tape-transport system was used for the rapid transfer of fission products to a low-background environment where their aggregate beta and gamma-ray spectra were measured as a function of delay time after neutron induced fission of {sup 235}U, {sup 238}U and {sup 239}Pu. Beta and gamma-ray energy distributions have been deduced for delay times as short as 0.2 s and extending out to 100,000s. Instrumentation development during the initial phase of the project included: (1) assembly and characterization of a NaI(Tl) spectrometer for determining aggregate gamma-ray energy distributions, (2) development and characterization of a beta spectrometer (having excellent gamma-ray rejection) for measuring aggregate beta-particle energy distributions, (3) assembly and characterization of a Compton-suppressed HPGe spectrometer for determining gamma-ray intensities of individual fission products to deduce fission-product yields. ...
1997-05-01
Analysis of log rate noise in Ontario's CANDU reactors
Energy Technology Data Exchange (ETDEWEB)
In the fall of 2003, the operators noticed that in the recently-refurbished Bruce A Shutdown System no. 1 (SDS1) the noise level in Log Rate signals were much larger than before. At the request of the Canadian Nuclear Safety Commission (CNSC), all Canadian CANDU reactors took action to characterize their Log Rate noise. Staff of the Inspection and Maintenance Services division of Ontario Power Generation (OPG) has collected high-speed high-accuracy noise data from nearly all 16 Ontario reactors, either as part of routine measurements before planned outages or as a dedicated noise recording. This paper gives the results of examining a suitable subset of this data, with respect to the characteristics and possible causes of Log Rate noise. The reactor and instrumentation design is different at each station: the locations of the moderator injection nozzles, the location of the ion chambers for each system, and the design of the Log Rate amplifiers. It was found that ...
2007-07-01
Energy Technology Data Exchange (ETDEWEB)
Based on the IAPWS technical guidance on ''Instrumentation for Monitoring and Control of Cycle Chemistry for Steam-Water Circuits of Fossil-Fired and Combined Cycle Power Plants,'' the latest situation regarding instrumentation for nuclear power plants is discussed. As a result of the discussion, it is concluded that: (1) Reliable and safe operation of plants is established by the application of suitable chemical conditions in plant cooling systems, which should be supported by the selection of suitable control targets for monitoring and by the application of reliable instruments. (2) The minimum level of key instrumentation consists of on-line as well as off-line instruments for monitoring the key parameters: - on-line: pH, conductivity, cation conductivity, O{sub 2} and H{sub 2} concentrations, electrochemical corrosion potential; - off-line: ...
2010-05-15
Energy Technology Data Exchange (ETDEWEB)
Instrumental neutron activation analysis (INAA) followed by gamma-ray spectrometry was used to determine the concentrations of As, Ca, Co, Cr, Cu, Eu, Fe, K, La, Mg, Mn, Mo, Na, Pr, Sb, Se, Th, U, V and Z, in 82 leaf samples belonging to two cultivars of pigeonpea (Cajanus cajan (L.) Millsp). Pigeonpea, an easy cultivation legume species, probably originated from Africa and adapted to brazilian conditions, is a very promising and unconventional source of food, mainly to the grain production intended for human feeding, and that even can be used in flour products. It is an excellent proteic supplement for ruminants, due to its large potential of forage production and its high nutritive value, or in addition it can be used in the recuperation of exhausting soils either by means of its utilization as green manure or by taking free Nitrogen from the atmosphere to produce nitrates which can be utilized by the plants. However, in spite of the several ...
2001-07-01
Radon gas monitoring survey for the determination of Radon Prone Areas in Lombardia
Energy Technology Data Exchange (ETDEWEB)
Region Lombardia has carried out a radon gas monitoring survey on its territory to localize radon prone areas as by law 241/00 enacted. To plan the survey, the Lombardia territory has been divided into two different types according to the morphology as well as the presence of a substratum of rock. The area with hills and mountains has been investigated with more attention compared to the plain because we can assume higher variability in radon concentration distribution due to the geological and morphological characteristics. The territory subdivision was based on the standard grid.. of the techniregional cartography (8 x 5 km). To perform radon indoor concentration measurements about 3600 measuring points were selected. They are located at the ground floor of buildings with the characteristics to ensure the tests are representative and comparable. It has also been taken into account evaluations done with previous surveys in accordance with the defined specification of the sites. The ...
2006-07-01
The Micro-X Imaging Spectrometer Instrument
The Micro-X instrument is a NASA funded, rocket borne X-ray imaging spectrometer planned for launch in January 2011. An array of Transition Edge Sensors (TESs) will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. This will be a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat sink, and will be read out by a SQUID time division multiplexer. X-rays will be focused onto the TES array of 128 pixels on a 600 micron pitch by a conically approximated Wolter optic with an effective area of 200 cm2. The spectrometer will have a field of view of 11.8 arcmin. We describe the design and development progress of the instrument.
2010-01-01
Policies to promote sustainable consumption: Innovative approaches in Europe
British Library Electronic Table of Contents (United Kingdom)
Abstract Policy-makers are increasingly recognising that the promotion of more sustainable consumption patterns is an indispensable prerequisite for achieving sustainable development in the long term. Policy documents and action plans have been published, and a wide array of policy instruments has been implemented with the aim of reducing the environmental and social burdens of consuming goods and services. But what are the latest trends and innovative approaches in sustainable consumption (SC) policies? What could be learnt for future policy-making? Based on an overview of European policy instruments and several case studies, the paper discusses instructive examples of SC policy instruments, in particular the Danish information campaign "One Tonne Less", the Dutch tax incentive scheme "Gr...
2010-01-01
Method of feeding a coolant into a reactor
International Nuclear Information System (INIS)
Object: To suppress a quantity of impurities in a coolant fed into a reactor vessel. Structure: The concentration of oxygen in a coolant flowing from a condensation desalting instrument into a feed and condensation piping is measured by an oxygen-concentration detector to feed its signal to an adjusting instrument. A degree of opening of an oxygen flow control valve to maintain the concentration of oxygen in the cooling water flowing within the pipe in the range from about 10 to about 200 ppb. Also, the concentration of oxygen in the cooling water fed to the desalting instrument is maintained at a level less than 2 ppb. Thereby, the total amount of iron flown into the vessel can be suppressed to a fine amount such as less than about 1 ppb. (Kawakami, Y.).
Materials and Components Technology Division research summary, 1992
Energy Technology Data Exchange (ETDEWEB)
The Materials and Components Technology Division (MCT) provides a research and development capability for the design, fabrication, and testing of high-reliability materials, components, and instrumentation. Current divisional programs related to nuclear energy support the development of the Integral Fast Reactor (IFR): life extension and accident analyses for light water reactors (LWRs); fuels development for research and test reactors; fusion reactor first-wall and blanket technology; and safe shipment of hazardous materials. MCT Conservation and Renewables programs include major efforts in high-temperature superconductivity, tribology, nondestructive evaluation (NDE), and thermal sciences. Fossil Energy Programs in MCT include materials development, NDE technology, and Instrumentation design. The division also has a complementary instrumentation effort in support of Arms Control Technology. Individual abstracts have been ...
1992-11-01
International Nuclear Information System (INIS)
The Institute of Electrical and Electronic Engineers (IEEE) standards for the quality assurance requirements for the design and manufacture of Class 1E instrumentation and electric equipment for a nuclear power generating station are presented. This standard establishes Quality Assurance Program requirements for electrical manufacturers. This standard, used in conjunction with ANSI N45.2-1977 and the supplemental standards to the extent referenced in this standard, is intended to meet the requirements of 10CFR50, Appendix B. These requirements are intended to assure that Class 1E instrumentation and electric equipment are responsibly engineered and manufactured from proper materials, that the manufacturing processes and practices are controlled, and that the manufacturing process produces a product of the required quality for Class 1E application.
Automation in urinalysis: evaluation of three urine test strip analysers.
A clinical laboratory evaluation was conducted on the Clinitek Auto 2000, the Super Aution Analyzer and the Urotron RL9 for the determination of glucose, protein, pH, blood, ketone-bodies and bilirubin.Precision of the systems was tested using three commercial control urine materials, and reported as the percentage of times the instrument repeats a certain value. Good repeatability was obtained with all the instruments.Accuracy of the systems was evaluated by comparison with quantitative procedures, and to check agreement between methods yielding semi-quantitative and quantitative results, ranges of acceptability were defined, based on the criteria reported in a previous paper [2]. It was then found that 87.5 to 98.9% of results from the Urotron RL9 and the Clinitek Auto 2000 were acceptable. With the Super Aution Analyzer the level of agreement was apparently lower because of the higher number of concentration steps used by this ...
1988-01-01
Traces of evidence. Nuclear forensics and illicit trafficking
International Nuclear Information System (INIS)
An IAEA databank lists a number of reported cases of illicitly trafficked nuclear or other radioactive materials. Apart from the traditional concern with nuclear proliferation, the post September 11th public is now wary of a possible attack by terrorists with a nuclear or radiation dispersion device (RDD). Until now, the seized quantities have not been sufficient to manufacture a nuclear explosive device, but they might be enough to construct an RDD. Recognizing the latent global challenge to public health and safety, the G8 States (Japan, USA, Germany, France, UK, Italy, Canada, and Russia) have called for 'joint international efforts to identify and suppress illicit supply' of, and demand for, nuclear material and to deter potential traffickers. One measure gaining in significance is to identify seized material and trace it back to its origin the objective of an emerging science known as nuclear forensics. Repeatedly nuclear or other radioactive material of unknown origin are ...
2003-06-01
Wafer and Solar Cell Characterization by GT-PVSCAN6000
The PVSCAN is an instrument designed to characterize silicon solar cell materials and devices. It performs a host of measurements that yield spatial maps of dislocation density, grain distribution, reflectance, and photoresponses from near-junction and the bulk of a solar cell.
2002-08-01
Visual recovery after vitrectomy for macular hole using 25-gauge instruments
British Library Electronic Table of Contents (United Kingdom)
Abstract. Purpose: To determine whether vitrectomy with 25-gauge instruments contributes to better postoperative visual recovery after macular hole (MH) surgery. Methods: The medical records for 46 consecutive eyes operated for MH by a single surgeon were retrospectively examined. Vitrectomy had been performed with a 25-gauge instrument in 23 eyes (25-G group) and with a 20-gauge instrument in 23 eyes (20-G group). Postoperative visual acuity (VA) in logMAR (logarithm of the minimum angle of resolution) units after 1 week and 1, 3, 6, 9 and 12 months, operating time, and volume of intraocular irrigating fluid were compared between the two groups. Results: Mean preoperative logMAR VA was 0.72 in the 25-G group and 0.68 in the 20-G group (p = 0.282, unpaired t-test). One week after surgery, ...
2008-01-01
UK PubMed Central (United Kingdom)
Recent research has implicated the nucleus accumbens (NAc) in consolidating recently acquired goal-directed appetitive memories, including spatial learning and other instrumental processes. However,...Full Text Available
2005-04-26
THE OGIP FORMAT FOR 2-D (IMAGE) POINT SPREAD FUNCTION ... - NASA
tial/angular spreading of incident photons from a point source caused by the instrument (de- .... Filter. CDTP0001= 'DATA. ' / Type of calibration. CCNM0001= '2D_PSF ' ... the final resolution of sigma=0.5 arcmin in all energy bands. ...
Superconducting gravity gradiometer for sensitive gravity measurements. I. Theory
Energy Technology Data Exchange (ETDEWEB)
Because of the equivalence principle, a global measurement is necessary to distinguish gravity from acceleration of the reference frame. A gravity gradiometer is therefore an essential instrument needed for precision tests of gravity laws and for applications in gravity survey and inertial navigation. Superconductivity and SQUID (superconducting quantum interference device) technology can be used to obtain a gravity gradiometer with very high sensitivity and stability. A superconducting gravity gradiometer has been developed for a null test of the gravitational inverse-square law and space-borne geodesy. Here we present a complete theoretical model of this instrument. Starting from dynamical equations for the device, we derive transfer functions, a common mode rejection characteristic, and an error model of the superconducting instrument. Since a gradiometer must detect a very weak differential gravity signal in the midst ...
1987-06-15
Sterilization wave of the future: Microwaves
Energy Technology Data Exchange (ETDEWEB)
Every cook knows that microwaves and metal don't mix. But scientists at the National Institute of Standards have devised a way to make them compatible. If it all pans out, hospitals may be able to sterilize medical instruments and waste in a device similar to a conventional microwave oven.
1989-11-05
Stereoscopic observations of a solar hard x-ray flare with Ulysses, PVO, GRO and Yohkoh spacecraft
Energy Technology Data Exchange (ETDEWEB)
Hard X-ray/gamma-ray spectrometers aboard two interplanetary spacecraft, Ulysses and Pioneer Venus Orbiter (PVO), and two near-Earth spacecraft, Yohkoh and Compton Gamma Ray Observatory (GRO/BATSE), are currently in operation. A unique set of circumstances have permitted the observation of the 15 November 1991 (2238 UT) flare by all the four instruments. This intense flare (GOES class X 1.5) was associated with the bright (3B) H-alpha flare located on the disk (S13, W19) in the active region 6919. At the time of the flare, the Ulysses and PVO spacecraft were located respectively 101[degree] and 52[degree] west of the Sun-Earth line. Thus the view angles for the PVO and Ulysses instruments were quite different from those of the near-Earth instruments on GRO and Yohkoh. The preliminary photon energy spectra observed by the four instruments at different times during the flare will be presented and their ...
1992-01-01
Spacecraft and Instruments - NASA
Aerosol Polarimetry Sensor (APS) + Continuous along-track scanning ... side of the spacecraft and faces outward, measures the intensity of incoming solar ... on a larger rocket, and faced slightly different conditions in spaceinto Glory wasn't ...
Safety limits for utilization of secondary mining operations at deposits
Energy Technology Data Exchange (ETDEWEB)
A procedure was developed to monitor boundaries within which secondary mining operations can be applied. Principal techniques include instrument and operative-remote observations of earth shifts and aerial photography of displacements on the surface of the trough.
1982-01-01
Psychometric Properties of the KPAS in Diverse Ethnic Groups of Midlife Women
UK PubMed Central (United Kingdom)
Although the Kaiser Physical Activity Survey (KPAS) was a potential instrument for cross cultural research of midlife women, little information is available on its reliability and validity among...Full Text Available
2009-12-01
Proceedings of the eighth West Virginia University international mining electrotechnology conference
Energy Technology Data Exchange (ETDEWEB)
A total of 25 papers were presented at the conference in 6 sessions: illumination and communication; power and safety; knowledge based systems; mine-wide monitoring; instrumentation control and automation; remote sensing and imaging.
1986-01-01
Position-sensitive proportional counter for space-based X-ray imaging studies
International Nuclear Information System (INIS)
ASTROSAT, India's first dedicated astronomy satellite is slated for launch in 2007. The primary science objective of ASTROSAT is to explore the Universe using broad-band instruments covering optical, UV, soft X-ray and hard X-ray studies
2005-03-01
Novel remote sensing gas outburst detector
Energy Technology Data Exchange (ETDEWEB)
The possibility has been explored of using a laser scattering technique to detect the imminent onset of rock activity associated with gas outbursts. The instrument described in this paper provides a sensitive, remote and rapid means of passively monitoring micro-seismic activity at the exposed face.
1984-08-01
NASA Surfs the Skies Above Oahu, Hawaii
National Aeronautics and Space Administration (NASA)
This flyover of the Hawaiian island of Oahu was made by draping Jan. 13, 2010, image data from the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) instrument on NASA's Terra spacecraft over new ASTER Version 2 digital elevation data.
2011-10-17
International Nuclear Information System (INIS)
Object: To prevent coolant inventory within a cooling system loop in an atomic power plant from being varied depending on loads thereby relieving restriction of varied speed of coolant flow rate to lowering of a liquid surface due to short in coolant. Structure: Instruments such as a superheater, an evaporator, and the like, which constitute a cooling system loop in an atomic power plant, have a plurality of free liquid surface of coolant. Portions whose liquid surface is controlled and portions whose liquid surface is varied are adjusted in cross-sectional area so that the sum total of variation in coolant inventory in an instrument such as a superheater provided with an annulus portion in the center thereof and an inner cylindrical portion and a down-comer in the side thereof comes equal to that of variation in coolant inventory in an instrument such as an evaporator similar to the superheater. which is provided with an ...
Integration and Testing of the Micro-X Rocket Payload
The Micro-X instrument is a rocket borne, X-ray imaging spectrometer planned for launch in October 2011. An array of 128 Transition Edge Sensors (TESs) on a 600 micron pitch will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. X-rays will be focused onto the TES array by a conically approximated Wolter optic with an effective area of 300 cm^2 giving the instrument a field of view of 11.8 arcmin. This performance will constitute a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat bath, and will be read out by a SQUID time division multiplexer. The first flight of the Micro-X instrument will observe the Puppis A supernova remnant. Future targets ...
2011-05-01
How representative was the 1996 VOTALP Mesolcina Valley campaign?
Energy Technology Data Exchange (ETDEWEB)
Each meteorological measurement reflects the conditions under which it was obtained, e.g. site, weather, and instrumentation. It is shown how the VOTALP Intensive Observation Periods (IOPs) were embedded in the climatic context of the summer months of 1996. (author) 1 fig., 2 refs.
1999-08-01
HPA - Radon Calibration Facilities
... Radon gas concentrations are measured using instruments with calibrations traceable to the UK National Physical Laboratory and PTB, Germany. The primary facility is a 43 m3 walk-in chamber accessed by an airlock. Radon gas is maintained at a level in this chamber that is ...
Future metrology needs for FEL reflective optics.
Energy Technology Data Exchange (ETDEWEB)
An International Workshop on Metrology for X-ray and Neutron Optics has been held March 16-17, 2000, at the Advanced Photon Source, Argonne National Laboratory, near Chicago, Illinois (USA). The workshop gathered engineers and scientists from both the U.S. and around the world to evaluate metrology instrumentation and methods used to characterize surface figure and finish for long grazing incidence optics used in beamlines at synchrotrons radiation sources. This two-day workshop was motivated by the rapid evolution in the performance of x-ray and neutron sources along with requirements in optics figure and finish. More specifically, the performance of future light sources, such as free-electron laser (FEL)-based x-ray sources, is being pushed to new limits in term of both brilliance and coherence. As a consequence, tolerances on surface figure and finish of the next generation of optics are expected to become tighter. The timing of the workshop provided an ...
2000-09-21
Final Report on the Evaluation of the NSF's Instructional Materials Development Program
... of the Evaluation of the Instructional Materials Development Program (PDF, 412 kb) Chapter I ... kb) Appendix 2: Instrument for Evaluating Materials (PDF, 935 kb) Appendix 3: Classroom Observation ...
FFTF reactor assembly system technology
An overview is presented of the FFTF reactor and plant together with descriptions of core components, core internals, core system, primary and secondary control rod system, reactor instrumentation, reactor vessel and closure head, and supporting test programs. (DG)
1975-11-13
FFTF reactor assembly system technology
International Nuclear Information System (INIS)
An overview is presented of the FFTF reactor and plant together with descriptions of core components, core internals, core system, primary and secondary control rod system, reactor instrumentation, reactor vessel and closure head, and supporting test programs.
1976-03-13
UK PubMed Central (United Kingdom)
The effects of Escherichia coli endotoxin on lung mechanics, hemodynamics, gas exchange, and lung fluid and solute exchange were studied in 12 chronically instrumented unanesthetized sheep. A possible...Full Text Available
1983-07-01
Diesel equipment: is it safe to use underground
Energy Technology Data Exchange (ETDEWEB)
Research indicates that diesel equipment can be used safely in undergound coal mines provided that certain conditions prevail. These conditions are: the machines and engines are approved for underground use, an adequate maintenance and training program is in effect, an adequate monitoring system with proper instrumentation is used, and adequate ventilation is maintained.
1984-04-01
Diabetes mellitus patients' family caregivers' subjective quality of life.
UK PubMed Central (United Kingdom)
OBJECTIVES: To assess the subjective quality of life (QOL) of family caregivers of Sudanese type-1 and type-2 diabetic outpatients, using the WHO 26-item QOL instrument, compared with a general population...Full Text Available
2006-05-01
Development of an Interference Electron Microscope.
This report covers a further year's work on the development of an Interference Electron Microscope at Imperial College. The instrument is unlike others of its type which have been operated. The basic innovations are to produce the critical illumination co...
1967-01-01
UK PubMed Central (United Kingdom)
PurposeTo develop a generic instrument for measuring short-term health status in the recovery period among patients undergoing abdominal and pelvic surgery.Full Text Available
2008-08-01
As part of an investigation of the mechanisms of coastal change in the Carolinas (http://woodshole.er.usgs.gov/project-pages/cccp/index.html), instrumented tripods were deployed on Diamond Shoals near Cape Hatteras, NC. These tripods recorded data quantifying the currents, waves, turbidity, temperat...
2010-01-26
UK PubMed Central (United Kingdom)
ObjectiveIn the context of the importance of valid self-report measures to research and evidence-based practice in social work, an argument-based approach to validity...Full Text Available
2004-05-01
Atmospheric electrodynamics in the U. S. - 1987-1990
Energy Technology Data Exchange (ETDEWEB)
Atmospheric electrodynamics research is summarized, focusing on three general areas: the ionosphere as a source for middle atmospheric electrodynamics, regional and global scale electrodynamics, and thunderstorms and lightning. New or improved instrumentation techniques which have furthered atmospheric electrodynamics research are also discussed. 93 refs.
1991-01-01
... hearing protection since you play, sit or stand near loud instruments and speakers. Here are a few ... piper's calling you to join him" Led Zeppelin (Robert Plant), "Stairway to Heaven" "My ears are ringin' ...
5 - NASA Technical Reports Server
The mission includes a reflected solar instrument retrieving at-sensor .... incoming solar radiation. This direct aerosol radiative forcing (DARF) ... examining the behavior of geosynchronous rocket bodies and non-stabilized payloads as ...
Summary on experimental facilities and future developments at SINQ
Energy Technology Data Exchange (ETDEWEB)
With 13 experimental facilities under construction to become available during the first year of SINQ operation, a nearly complete suite of options for users will be made available to carry out research with neutrons at PSI. Three more facilities are under design and will come on line somewhat later. To complete the suite, three more specialized instruments are being evaluated. SINQ being a novel neutron source concept, significant scope for improvement is also seen on the source side. It is a major goal of PSI to exploit these opportunities and to make - among others - use of neutron instruments to carry out the necessary research. (author) 9 figs., 1 tab., 11 refs.
1996-11-01
International Nuclear Information System (INIS)
The following Resolution has been stated because of the results of the workshops Elaboration of proposals for strategic guidelines held from 2 to May 5, 2006, elaboration of proposals for the Strategic Lines instruments held from 24 to July 28, 2006, as well as documents Proposal of politic energetic Uruguayan Energy Sector development and proposal of Energy Policy Instruments developed by the National Directorate of Nuclear Energy and Technology and the Energy Strategy Guidelines Uruguay 2006.
2006-10-12
Remote monitoring of a coal waste impoundment in West Virginia. Open file report Oct 78-Sep 81
Energy Technology Data Exchange (ETDEWEB)
This report addresses remote monitoring of coal waste impoundments for stability. Existing automated geotechnical monitoring systems are described and reviewed along with details of instruments suitable for such systems. An impoundment in West Virginia, which was in the construction stage, was instrumented and monitored between July 1979 and May 1981. Sensors that measure surface and subsurface parameters including settlement, horizontal deflection, surface tilt, pore water pressure, seepage, pond level, and meteorlogical parameters were installed. Recommendations for improving and expanding the capabilities of the monitoring system are given.
1982-02-01
Fiber optic quality assurance at the Nevada Test Site
Energy Technology Data Exchange (ETDEWEB)
A large number of fiber optic cables were used in support of a neutron imaging experiment at the Nevada Test Site. This paper describes the quality control testing of fiber components used on this experiment. The principal reason for quality control testing was to ensure reliable, high transmission fibers; a secondary reason was to gain data on a large sample of fiber cables in the field. Also described is the instrumentation developed for carrying out these field measurements. The design of the quality control instrumentation was a compromise between accuracy and simplicity of use.
1981-01-01
Development of electro-optical instrumentation for annular two-phase flow studies
International Nuclear Information System (INIS)
The development of new electro-optical instrumentation for studying the annular dispersed two-phase flow regime is described. The system measures the thickness of the water film and droplet size and velocity distributions which would be encountered in such a flow regime. The water film thickness is measured by an improved capacitance method with a short time constant using newly developed sensor electrodes. The electrodes are made flush with the inner wall of a cylindrical tube and do not disturb the flow. In the test equipment, steady, laminar flow of water along the inner wall of the tube is controlled by appropriate valves and a porous jacket while droplets are introduced by means of a special spray nozzle.
1981-01-01
Determining surface profile from sequential interference patterns from a long trace profiler
Energy Technology Data Exchange (ETDEWEB)
The Long Trace Profiler (Takacs et al.) is a slope-measuring instrument which was introduced several years ago. Development of this instrument continues at Lawrence Berkeley Laboratory in improving both hardware design and software algorithms for turning the raw interference data (a sequence of intensity patterns) into properly interpreted representations of surface slope and height. This report presents a mathematical model of the interference pattern and methods of extracting the slope and height profile from such patterns. 9 refs.
1991-07-01
Axiomatic Design Approach for a Reactor Head Structure Assembly
Energy Technology Data Exchange (ETDEWEB)
Korea Atomic Energy Research Institute (KAERI) has been developing the integral reactor. The reactor head structure assembly (RHSA) is the structure installed over the reactor cover. Due to the characteristics of an integral reactor, there are many instrument cables and power cables coming out from the reactor cover and main components. The RHSA provides an interface location to connect these cables from Architecture Engineer (AE) and System Designer (SD). It also prevents a pipe whip and it prohibits instruments from becoming missiles. In this research, the axiomatic design approach for the RHSA is performed.
2006-07-01
An advanced NDA workstation for integrated safeguards
International Nuclear Information System (INIS)
In this paper the authors describe the design and development of an advanced NDA workstation, which fits into an integrated data evaluation scheme for safeguards. This kind of instrument must be sort of an intelligent assistant to the inspection procedure, be able to generate as correct as possible measurements, guide the inspector throughout the procedure, and report descriptive data to the data evaluation system. The problem of improving the quality of the measurement is tackled using a simple expert system, which should convey in the instrument some of the physicist knowledge. The authors describe the hardware and software resources which were included in their design to reach the intended goal. A prototype of the machine has been built, and a preliminary software for Plutonium Isotopic Composition is under development.
1986-06-22
Energy Technology Data Exchange (ETDEWEB)
Reinforcement of the legislation concerning the emission of atmospheric pollutants, aerosols, refrigerants, solvents etc and the reduction of the greenhouse effect, has led to the development of performing instruments for the survey and control of ambient air quality and for the limitation of exhaust gases, combustion products, volatile organic compounds (VOC), particulates and noxious compounds in the atmosphere. This study is divided in 4 main parts. The first part describes the context of the air quality control: the problems linked with the environment and health, the pollutants characteristics, the pollution levels and the detection sensitivity of instruments according to the different type of pollutants (petroleum products, VOCs, ozone compounds, particulates, smells..), the protocols of air pollution measurements and their application (chimney smokes, industrial volatile compounds, indoor and ambient air quality, exhaust gases from ...
1996-11-01
Nuclear forensics support. Reference manual
International Nuclear Information System (INIS)
Illicit trafficking of nuclear and other radioactive material has been an issue of concern since the first seizures in the early 1990s. By the end of 2004 Member States had confirmed 540 cases, while about another 500 remain unconfirmed. Most of the confirmed cases have a criminal dimension, even if they were not for known terrorist purposes. The attacks of September 2001 in the USA dramatically emphasized the requirement for the enhanced control and security of nuclear and other radioactive material. In response to a resolution by the IAEA General Conference in September 2002 the IAEA has adopted an integrated approach to protection against nuclear terrorism. This brings together IAEA activities concerned with the physical protection of nuclear material and nuclear installations, nuclear material accountancy, detection and response to illicit nuclear trafficking, the security and safety of radioactive sources, emergency response measures - including pre-emergency measures in Member ...
Genetic Modification of Short Rotation Poplar Biomass Feedstock for Efficient Conversion to Ethanol
Energy Technology Data Exchange (ETDEWEB)
The Bioenergy Feedstock Development Program, Environmental Sciences Division, Oak Ridge National Laboratory is developing poplars (Populus species and hybrids) as sources of renewable energy, i.e., ethanol. Notable increases in adaptability, volume productivity, and pest/stress resistance have been achieved via classical selection and breeding and intensified cultural practices. Significant advances have also been made in the efficiencies of harvesting and handling systems. Given these and anticipated accomplishments, program leaders are considering shifting some attention to genetically modifying feedstock physical and chemical properties, so as to improve the efficiency with which feedstocks can be converted to ethanol. This report provides an in-depth review and synthesis of opportunities for and feasibilities of genetically modifying feedstock qualities via classical selection and breeding, marker-aided selection and breeding, and genetic transformation. Information was collected ...
2000-08-30
FDS3 simulations of indoor hydrocarbon fires engulfing radioactive waste packages
International Nuclear Information System (INIS)
The thermal environment of a hypothetical large indoor hydrocarbon pool fire is more complex compared to outdoor fires and can be more severe for engulfed objects. In order to analyze potential thermal environments for interim storage of spent fuel casks or low-level radioactive waste packages engulfed in pool fires numerical simulations with the CFD fire code FDS3 were carried out for different storage configurations. In addition, data of indoor pool fire experiments were used to validate the model for this type of application. A series of pool fire experiments under different ventilation conditions and varied pool surface (1 m"2 - 4 m"2) inside a compartment of 3.6 m x 3.6 m x 5.7 m was conducted at iBMB (Institut fuer Baustoffe, Massivbau und Brandschutz) of Braunschweig University of Technology, Germany. The instrumentation included thermocouples, heatflux and pressure gauges, bi-directional flow probes and gas concentration measurements. A mock low-level waste ...
2004-09-20
International Nuclear Information System (INIS)
Full text: The ITWG was first formed in 1995 for the purpose of fostering international cooperation for combating illicit trafficking of nuclear materials. The initial focus for the ITWG was on the development of nuclear forensics to help answer attribution questions regarding nuclear materials of unknown origin. More recently, the ITWG has also expanded its focus to include detection of nuclear materials during transit. This paper presents some of the key developments by this group and their potential impact for combating nuclear smuggling. The initial focus of the ITWG was to write a status report on international cooperation on nuclear smuggling forensic analysis. This 26-page report summarized previous work on nuclear forensics and gave an initial analysis on prioritizing techniques and methods for forensic analysis regarding source and route attribution. This report was submitted to the G-8 countries, and shortly ...
2002-10-21
Lessons from a European study[Financing Renewable Energy Systems
Energy Technology Data Exchange (ETDEWEB)
A large number of proven technical solutions exists for the use of renewable energies (RE). However, their dissemination is still too slow to meet the political goal of substituting 12 % of the primary energy demand in the European Union by the year 2010. Even renewable energy systems (RES) with economic potential are only partly exploited. There is a long literature concerning the barriers to RE use. In particular it has become clear that the availability of finance and the forms and conditions upon which it is lent have a major impact on RE deployment. An area of importance is the deficiency of appropriate ownership forms and properly adapted financing instruments in certain countries. Moreover, different regulations and institutional barriers in the European countries hinder the free flow of capital for RES within the European common market. On the other hand, solutions have been developed very successfully in individual countries. Differences in cultures and ...
2000-10-01
Implementation of renewable technologies - Opportunities and barriers. Zimbabwe country study
Energy Technology Data Exchange (ETDEWEB)
Renewable Energy Technologies (RETS) have over the years become an integral part of the energy supply chain in most developed countries. Recent projections show that 13.5% of the world's primary energy supply comes from renewable and this figure has an aggregated annual growth rate of 16%. Wind has the highest annual growth rate of 22% while the least annual growth rate of 2% is for hydropower. The main push for renewable like wind in the OECD countries are environmental concerns and the business aspect in power generation. The situation is however completely different in Africa, where the thrust for RETs is developmental based. Although the continent has abundant renewable energy resources like solar, biomass, wind and hydro potential, they have remained largely unexploited. Several efforts have been made to help African countries like Zimbabwe to exploit such resources. The main objectives of this country study included review of Zimbabwe's development of past RETs, ...
2001-07-01
Energy Technology Data Exchange (ETDEWEB)
A guidance document on the instrumentation for monitoring and control of cycle chemistry for the steam-water circuits of fossil-fired and combined-cycle power plants was developed within the IAPWS Power Cycle Chemistry Working Group. This technical guidance document has been authorized by the International Association for the Properties of Water and Steam (IAPWS) at its meeting in Doorwerth, The Netherlands, 6-11 September, 2009, for issue by its Secretariat. The members of the IAPWS are: Britain and Ireland, Canada, the Czech Republic, Denmark, France, Germany, Greece, Japan, Russia, and the United States of America, and the associate members Argentina and Brazil, Italy, and Switzerland. In order to achieve suitable chemical conditions in steam-water circuits it is essential to establish reliable monitoring of key parameters on every plant. This enables the demonstration of operation within cycle chemistry targets, and alerts the operators to the need to take ...
2009-10-15
Phase 2 Final Report. IAEA Safeguards: Implementation blueprint of commercial satellite imagery
International Nuclear Information System (INIS)
This document - IAEA Safeguards: Implementation Blueprint of Commercial Satellite Imagery - constitutes the second report from SSC Satellitbild giving a structured view and solid guidelines on how to proceed with a conceivable implementation of satellite imagery to support Safeguards activities of the Agency. This Phase 2 report presents a large number of concrete recommendations regarding suggested management issues, work organisation, imagery purchasing and team building. The study has also resulted in several lists of actions and preliminary project plans with GANT schedules concerning training, hardware and software, as well as for the initial pilot studies. In both the Phase 1 and Phase 2 studies it is confirmed that the proposed concept of a relatively small Imagery Unit using high-resolution data will be a sound and feasible undertaking. Such a unit capable of performing advanced image processing as a tool for various safeguard tasks will give the Agency an effective ...
1989-08-01
Techniques for measurement of velocity in liquid-metal MHD flows
Energy Technology Data Exchange (ETDEWEB)
Three instruments for measuring local velocities in liquid-metal MHD experiments for fusion blanket applications are being evaluated. The devices are used in room-temperature NaK experiments to measure three-dimensional flow field patterns anticipated in complex blanket geometries. Hot film anemometry, a standard technique in ordinary fluids, is being used, as well as two developmental devices. One is called the Liquid Metal Electromagnetic Velocity Instrument (LEVI), and performs essentially as a local dc electromagnetic flow meter. The third device, a Thermal Transient Anemometer (TTA) is a rugged, yet relatively simple device, which measures local velocity through the mechanism of convective heat transfer, in some ways similar to hot-film anemometry. Results are presented showing the kinds of data collected this far with each instrument. Measurements include both local velocity measurements and some preliminary frequency ...
1986-01-01
Second Quarter Report Environmental Biosciences Program
Energy Technology Data Exchange (ETDEWEB)
In May 2002, the United States Department of Energy (DOE) signed Assistance Instrument Number DE-FC09-02CH11109 with the Medical University of South Carolina (MUSC) to support the Environmental Biosciences Program (EBP). This funding instrument replaces DOE Assistance Instrument Number DE-FC02-98CH10902. EBP is an integrated, multidisciplinary scientific program, employing a range of research initiatives to identify, study and resolve environmental health risk issues. These initiatives are consistent with the Medical University's role as a comprehensive state-supported health sciences institution and the nation's need for new and better approaches to the solution of a complex and expansive array of environment-related health problems. The intrinsic capabilities of a comprehensive health sciences institution enable the Medical University to be a national resource for the scientific investigation of ...
2002-10-31
Remote disassembly of the absorber open-test assembly at the FFTF/IEM cell
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) interim examination and maintenance (IEM) cell is used for the remote disassembly of irradiated fuel and material experiments. The absorber open-test assembly (AOTA) is a 12-m (40-ft)-long instrumented absorber (control-rod-material) test assembly. Its primary purpose is to characterize the FFTF control-rod-material reaction rate during reactor operation. Instrumentation allowed temperature and pressure measurements at various locations in several absorber pins during reactor operation. After residing several months in the reactor, the assembly was transferred to the IEM cell by the closed-loop ex-vessel machine (CLEM) for separation of the irradiated portion of the experiment from the instrument stalk. After separation, the 3.6-m (12-ft)-long assembly was processed through the sodium removal system and shipped off-site for examination. This success allowed the timely completion of a major ...
1990-11-11
Optical Modelling of the HFI Instrument on Board the Planck Surveyor
The PLANCK SURVEYOR is a European Space Agency satellite mission to image the very faint anisotropies in the temperature of the Cosmic Microwave Background (CMB) radiation. Maynooth is actively participating in an international collaboration of scientists involved with the optical design of the High Frequency Instrument (HFI). This paper outlines research which has been undertaken in Maynooth concerned with numerical modelling of the optical characteristics of the multi-frequency array of detectors making up the HFI instrument. In the study the commercial software package ZEMAX was used to model the coupling of the focal plane HFI detectors to the PLANCK telescope. This package is particularly useful in the optical design of PLANCK because of the powerful optimisation features of the software. It is thus possible to readily determine the optimum positioning of the detectors in the focal plane of the telescope. Although the package is based on a ...
1999-07-01
The in-flight wavelength calibration for the Ozone Monitoring Instrument is discussed. The observed variability in the wavelength scale is two orders of magnitude larger than caused by temperature changes in the instrument. These wavelength variations are the result of rapid changes in time in the radiance levels during an individual observation in the presence of clouds or snow and ice. We have developed a data processing method to account and correct for these changes. In February 2005 this correction was implemented in the official data processing stream. We explain in detail how and how accurately this method works. Before correction, the error in the wavelength scale can be as much as a few tenths of a pixel; after correction it is mostly less than 1/100th of a pixel, which is the required preflight accuracy. This means that higher-level products such as the total column amounts of ozone, NO2, and SO2 are not significantly affected. It is ...
2006-05-01
Measuring instrument for radiometric monitoring of solids and heavy metals in water
International Nuclear Information System (INIS)
A combination of measuring instruments, consisting of a Beta-Sedimeter and a radionuclide X-ray fluorescence instrument, is described. With the Beta-Sedimeter the C-14-radiation is measured. Through direct irradiation with photons of a Pu238-source in an ancillary irradiation chamber and energy dispersing measurement of the K- and L-radiation resp. of the excited heavy metals with the aid of a Si(Li)-semiconductor detector and a 4-channel analyzer the heavy metal concentrations of the heavy metals Zn, Cr, Ni and Pb are determined. For the determination of cadmium the indirect excitation with Am-241 and Dy-targets is described. The system produces records and operates fully automatically in a step-by-step mode with a testing cycle of 45 minutes. In connection with the process monitoring of the wastewater from a zinc plating plant during a period of 8 months the concentration of the solid material and of the metals Cr and Zn, which were ...
1979-01-01
Measurement of the enrichment of uranium in the pipework of a gas centrifuge enrichment plant
Energy Technology Data Exchange (ETDEWEB)
The US and UK have been separately working on the development of a NDA instrument to determine the enrichment of gaseous UF/sub 6/ at low pressures in cascade header pipework in line with the conclusions of the Hexapartite Safeguards Project viz. the instrument is capable of making a ''go/no go'' decision of whether the enrichment is less than/greater than 20%. Recently, there has been a series of very useful technical exchanges of ideas and information between the two countries. This has led to a technical formulation for such an instrumentation based on ..gamma..-ray spectrometry which, although plant-specific in certain features, nevertheless is based on the same physical principles. Experimental results from commercially operating enrichment plants are very encouraging and indicate that a complete measurement including set up time on the pipe should be attainable in about 30 minutes ...
1985-01-01
Measurement of mud level interfaces: A tool for optimization of red mud washing at C.V.G. Bauxilum
Energy Technology Data Exchange (ETDEWEB)
For the expansion to 2.0 MTPY of the CVG Bauxilum alumina plant, the area of clarification and red mud washing was rearranged from four 2-thickener-5-washer trains to two 1-thickener-7-washer trains. As a result of this modification, the specific mud handling capacity of the existing tanks should be increased by almost 3-times. The time allowed for control actions was then significantly reduced, leading to the need of an on-line level detection system, in order to achieve a better and faster control of the operation. With this scope, it was developed and installed a new continuous mud level detector that gives the measurement of both mud and turbid zone levels in the tanks. The development of the new instrument started with an existing instrument for density measurements which was completely re-engineered in order to obtain the maximum readability in the densities founded along the full range of the tank height. Actually 28 tanks are equipped ...
1996-10-01
Energy Technology Data Exchange (ETDEWEB)
Analyses of the date obtained from the instrumented impact test and of its correlation with static and dynamic J integral values and various tensile properties are made in this study. It is shown that a dynamic bending yield load recorded in the instrumented Charpy V test can be easily converted to a dynamic tensile yield stress using Server's equation. It is also possible to estimate a true fracture strain, COD value, and SZW easily if the load point displacement is recorded. Temperature dependency of Charpy V energy and J integral values is rather well simulated by a curve fitting method. However, a half value transition temperture obtained in that method has no physical meaning. Dynamic J sub(ID) is larger than a static J sub(IC) in the ductile fracture range in this study. This rise is proportional to the yield stress ratio sigmasub(yd)/sigmasub(y)(--1.2-1.3). It is found, therefore, that the following relation exists in the both ...
1983-07-01
International Nuclear Information System (INIS)
Analyses of the date obtained from the instrumented impact test and of its correlation with static and dynamic J integral values and various tensile properties are made in this study. It is shown that a dynamic bending yield load recorded in the instrumented Charpy V test can be easily converted to a dynamic tensile yield stress using Server's equation. It is also possible to estimate a true fracture strain, COD value, and SZW easily if the load point displacement is recorded. Temperature dependency of Charpy V energy and J integral values is rather well simulated by a curve fitting method. However, a half value transition temperture obtained in that method has no physical meaning. Dynamic J sub(ID) is larger than a static J sub(IC) in the ductile fracture range in this study. This rise is proportional to the yield stress ratio #sigma#sub(yd)/#sigma#sub(y)(--1.2-1.3). It is found, therefore, that the following relation exists in the both cases; ...
Development and manufacture of tritium-in-air monitors for Indian PHWRs
International Nuclear Information System (INIS)
Tritium, a beta emitting gas at room temperature causes a biological hazard in the locations where it is present beyond acceptable limits. The hazard can be due to inhalation, and absorption by skin. Hence is the necessity of Tritium monitoring instruments/systems for ensuring safety in the PHWRs and the nuclear research plants and laboratories. It is desirable that the instruments address satisfactorily to certain factors like the following: (i) Wide range of Tritium concentrations - 1 to 104 DAC ( Derived Air Concentration) (ii) On-line monitoring features (iii) Small response time (On-spot instantaneous measurements) (iv) Portability (v) Mitigation of memory effects. This paper presents an overview of the Online Tritium in Air Monitoring Systems manufactured by ECIL for Pressurised Heavy Water Reactors at Tarapur, Kaiga, and Rawatbhata. Significant aspects of design, function, testing, limitations of the detectors and electronics and the ...
2009-10-01
Energy Technology Data Exchange (ETDEWEB)
The consistency of different instruments and methods for measuring two-dimensional (2D) power spectral density (PSD) distributions are investigated. The instruments are an interferometric microscope, an atomic force microscope (AFM) and the X-ray Reflectivity and Scattering experimental facility, all available at Lawrence Berkeley National Laboratory. The measurements were performed with a gold-coated mirror with a highly polished stainless steel substrate. It was shown that these three techniques provide essentially consistent results. For the stainless steel mirror, an envelope over all measured PSD distributions can be described with an inverse power-law PSD function. It is also shown that the measurements can be corrected for the specific spatial frequency dependent systematic errors of the instruments. The AFM and the X-ray scattering measurements were used to determine the modulation transfer function of the ...
2005-07-12
Energy Technology Data Exchange (ETDEWEB)
The consistency of different instruments and methods for measuring two-dimensional (2D) power spectral density (PSD) distributions are investigated. The instruments are an interferometric microscope, an atomic force microscope (AFM) and the X-ray Reflectivity and Scattering experimental facility, all available at Lawrence Berkeley National Laboratory. The measurements were performed with a gold-coated mirror with a highly polished stainless steel substrate. It was shown that these three techniques provide essentially consistent results. For the stainless steel mirror, an envelope over all measured PSD distributions can be described with an inverse power-law PSD function. It is also shown that the measurements can be corrected for the specific spatial frequency dependent systematic errors of the instruments. The AFM and the X-ray scattering measurements were used to determine the modulation transfer function of the ...
2005-04-17
Cooperative procurement: market transformation for energy efficient products
Energy Technology Data Exchange (ETDEWEB)
Cooperative procurement is a variation of public purchasing which may be used as an instrument to transform the market and stimulate innovation enhancing environmental performance. The core of the procedure is the following: Coordinated by a central agency a group of buyers - public administrations, but also private companies, associations, etc. - gets together and jointly formulates a catalogue of performance requirements for a specific product truly suiting their preferences. This catalogue may contain (combinations of) requirements not yet available on the market and includes energy efficiency and/or environmental performance among other preferences important to the users. On the basis of the product requirements the buyer group launches a call for tenders, evaluates the bids received from the manufacturers and commits to buying the winning product. Thus, a market is provided for the most successful innovators in a given area of technology. The paper discusses ...
1999-07-01
Energy Technology Data Exchange (ETDEWEB)
This report describes a comparison result of technical standards applied to instrumentation and control systems for nuclear power plants between in Korea and in Russia. Russia also has a state-run organization authorized to conduct approval, cancellation, and audit in use of nuclear facility or equipment. The Russian standards for nuclear instrumentation and control equipment are analogous with the Korean ones in the aspect of basic concepts and principles. However, there are some differences in document structure, design requirements, qualification test items, depth of contents between two standard systems. The biggest deviation exists in the standard documents for seismic qualification and electromagnetic interference qualification. Korean seismic qualification standard utilizing US approach, defines testing and qualification methods specifically and clearly. Russian standards however provide only conceptual definitions and requirements in ...
2005-04-15
Characterization of Radiation Instruments at the Summit of Mt. Fuji
International Nuclear Information System (INIS)
The opportunity of exposure to high-energy radiation up to GeV is increasing as in civilian aircrafts and at particle accelerators. The transport of such energetic particle is still difficult to describe precisely and thus verification by measurement using a well characterized instrument is indispensable for reliable dosimetry. However, no reference calibration field has been established for the high-energy range. We thus propose to use a facility at the summit of Mt. Fuji (3776 m in altitude; N35.36o, E138.73o), the highest place in Japan, for characterization of radiation instruments that are possibly used in high-energy radiation fields. For demonstration of the effectiveness, two moderator-type neutron monitors (NCN1 and WENDI-II) having different energy response functions were employed for cosmic-ray neutron measurements in the summer of 2009. In comparison with numerically simulated values, it was found that the extended energy neutron ...
2010-12-01
Energy Technology Data Exchange (ETDEWEB)
A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47, 073602 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A616, 172 (2010)]. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of ...
2011-03-14
Energy Technology Data Exchange (ETDEWEB)
A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47(7), 073602-1-5 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A 616, 172-82 (2010]. Here we report on a significant expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for ...
2010-07-26
Energy Technology Data Exchange (ETDEWEB)
The major problem of measurement of a power spectral density (PSD) distribution of the surface heights with surface profilometers arises due to the unknown Modulation Transfer Function (MTF) of the instruments. The MTF tends to distort the PSD at higher spatial frequencies. It has been suggested [Proc. SPIE 7077-7, (2007), Opt. Eng. 47 (7), 073602-1-5 (2008)] that the instrumental MTF of a surface profiler can be precisely measured using standard test surfaces based on binary pseudo-random (BPR) patterns. In the cited work, a one dimensional (1D) realization of the suggested method based on use of BPR gratings has been demonstrated. Here, we present recent achievements made in fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. The 2D BPRAs were used as standard test surfaces for 2D MTF calibration of the MicromapTM-570 interferometric microscope with all ...
2009-07-07
Behavior of instrumented model batter piles in clay
Energy Technology Data Exchange (ETDEWEB)
Pile foundations in several coastal and offshore structures are subjected to significant amounts of lateral loads due to wave action. Usually batter piles are adopted to resist large lateral loads. In this investigation an attempt has been made to study the behavior of batter pile in clayey soils through an experimental program carried out on instrumented model aluminium piles of 26 mm diameter in a test tank of size, 1,200 mm x 800mm x 1,100 mm. The pile was instrumented with electrical resistance type strain gauges to determine the bending moment variations along the depth of embedment of pile. Bending moment vis depth relationships were used to determine the Soil reaction (p) and lateral displacement (y) along the length of the pile for the applied load. From the bending moment vs depth curves it is found that depth of maximum bending moment is greater for negative batter pile than for vertical and positive batter pile. The data of soil ...
1995-12-31
Applications of a downhole programmable microprocessor for a geothermal borehole inspection tool
Energy Technology Data Exchange (ETDEWEB)
The high-temperature scanning borehole inspection system is currently being developed jointly by the Los Alamos National Laboratory (LANL) and Westfalische Berggewerkschaftskasse (WBK) of West Germany. The downhole instrument is a digital televiewer that utilized a microprocessor to digitize, process and transmit the acoustic information to the surface acquisition and control system. The primary operation of the downhole acoustic assembly uses a piezoelectric crystal acting as a receiver-transmitter which is mounted on the rotating head. The crystal emits a burst of acoustic energy that propagates through the borehole fluid with a portion of the energy reflected by the borehole wall back to the crystal. The time of travel and the amplitude of the reflected signal are conditioned by the microprocessor and transmitted along with other pertinent data to the surface data processing center. This instrument has been designed specifically for use in ...
1987-01-01
Pre-Flight Development of the PoGOLite Pathfinder
International Nuclear Information System (INIS)
The Polarized Gamma-ray Observer (PoGOLite) is a balloon-borne instrument that will measure gamma-ray polarization in the energy range 25-80 keV from astronomical sources such as pulsars, accretion discs and jets from active galactic nuclei. The two additional parameters provided by such observations, polarization angle and degree, will allow these objects to be studied in a new way, providing information about their emission mechanisms and geometries. The instrument measures azimuthal scattering angles of photons within a close packed array of phoswich detector cells (PDCs) based on coincident detection of Compton scattering and photoelectric absorption. Each PDC comprises three different scintillating components and combines photon detection, active collimation and bottom anticoincidence into one single unit. The three parts are viewed by a photomultiplier tube (PMT) and pulse shape discrimination is used to identify signals from dierent ...
Design of High-speed Wear Lifetime Tester of the Instrument Ball Bearings
Energy Technology Data Exchange (ETDEWEB)
The instrument ball bearings are the key components of movable components for various kinds of measuring and control instruments; they often operate in the environmental condition of high-speed and light preload. In general, the non metal, disposable oilimpregnated retainer material has been used for these kinds of high precision miniature bearing. The engineering practice shows that the common failure mode of them is the wear which appears under the condition of insufficient lubrication condition. As the results, the vibration and noise will be enlarged, so does the frictional torque, which makes the ball bearings to lose its original working accuracy. It is the lifetime test of bearings that can enable the designers and manufacturers to chose the material of the bearing properly, optimize the product structure, mend the manufacturing technique process, and to enhance the technical level of the bearing products significantly. In this paper, ...
2006-10-15
Well-test data from geothermal reservoirs
Energy Technology Data Exchange (ETDEWEB)
Extensive well testing in geothermal resources has been carried out throughout the western United States and in northern Mexico since 1975. Each resource tested and each well test conducted by LBL during the eight-year period are covered in brief. The information, collected from published reports and memoranda, includes test particulars, special instrumentation, data interpretation when available, and plots of actual data. Brief geologic and hydrologic descriptions of the geothermal resources are also presented. The format is such that well test descriptions are grouped, in the order performed, into major sections according to resource, each section containing a short resource description followed by individual test details. Additional information regarding instrumentation is provided. Source documentation is provided throughout to facilitate access to further information and raw data.
1982-09-01
The political and economic costs of a fully verifiable Kyoto Protocol
Energy Technology Data Exchange (ETDEWEB)
Until now policy makers and researchers considered the problem of uncertainty and verification to be of minor importance for the Kyoto process. However, the first studies that recently appeared on uncertainty estimation of carbon accounting reveal that uncertainties of the reported emissions on the country level are large. In an environment of such large uncertainties, verification of emission reductions must be viewed as a crucial mechanism to secure the very functioning of the Protocol. The paper provides a set of tools to strategically deal with the problem of uncertainty and verification under the Kyoto Protocol. This is done by: providing an overview of the instruments to deal with verification (no-, trend-, level- and top-down/bottom-up verification under PCA and FCA); compute costs scenarios for those instruments under various flexibility scenarios; and providing a short discussion on practical steps and crucial decisions to be made that ...
2000-11-01
The electron cyclotron absorption diagnostic for the JET pumped divertor plasma
International Nuclear Information System (INIS)
We present the design of a diagnostic system to measure electron cyclotron absorption at the second harmonic E-mode resonance in the JET pumped divertor plasma. The diagnostic will measure transmission as a function of frequency along one or more sightlines from which the spatial profile of the n_eT_e product will be deduced. The divertor is briefly described, and the electron cyclotron resonance physics relevant to this measurement is reviewed. The problems of measuring transmission using an oversized transmission system are discussed and the chosen measurement technique, a swept frequency interferometer using a coherent radiation source, is described. A prototype of the instrument has been assembled to test the measurement technique. Some data demonstrating the instrument's characteristics are presented. The nonresonant losses, which may affect the interpretation of the measurement, are also discussed. (orig.).
1993-03-01
Energy Technology Data Exchange (ETDEWEB)
The conference was organized to bring together scientific and business people from Canada, United States, and Mexico to foster the protection and improvement of the environment and to promote sustainable development in the three NAFTA countries. The sessions are international cooperation and partnerships (panel discussion), markets, market access, economic instruments, venture and capital growth, economic instruments versus regulations, international financial institutions, partnerships and networks, government support programs (panel), acid rain, stratospheric ozone, smog and ground level ozone, innovative measurement methods, hazardous air pollutants, respirable fine particulates, climate change prevention technologies, pollution prevention technologies, indoor air technology, and posters. Selected papers have been abstracted separately.
1994-09-01
The VOISE Algorithm: a Versatile Tool for Automatic Segmentation of Astronomical Images
The auroras on Jupiter and Saturn can be studied with a high sensitivity and resolution by the Hubble Space Telescope (HST) ultraviolet (UV) and far-ultraviolet (FUV) Space Telescope spectrograph (STIS) and Advanced Camera for Surveys (ACS) instruments. We present results of automatic detection and segmentation of Jupiter's auroral emissions as observed by HST ACS instrument with VOronoi Image SEgmentation (VOISE). VOISE is a dynamic algorithm for partitioning the underlying pixel grid of an image into regions according to a prescribed homogeneity criterion. The algorithm consists of an iterative procedure that dynamically constructs a tessellation of the image plane based on a Voronoi Diagram, until the intensity of the underlying image within each region is classified as homogeneous. The computed tessellations allow the extraction of quantitative information about the auroral features such as mean intensity, latitudinal and longitudinal ...
2009-01-01
Radiation hardening of smart electronics
International Nuclear Information System (INIS)
Microprocessor based ''smart'' pressure, level, and flow transmitters were tested to determine the radiation hardness of this class of electronic instrumentation for use in reactor building applications. Commercial grade Complementary Metal Oxide Semiconductor (CMOS) integrated circuits used in these transmitters were found to fail at total gamma dose levels between 2500 and 10,000 rad. This results in an unacceptably short lifetime in many reactor building radiation environments. Radiation hardened integrated circuits can, in general, provide satisfactory service life for normal reactor operations when not restricted to the extremely low power budget imposed by standard 4--20 mA two-wire instrument loops. The design of these circuits will require attention to vendor radiation hardness specifications, dose rates, process control with respect to radiation hardness factors, and non-volatile programmable memory technology. 3 refs., 2 figs.
Policy of air protection in Poland
International Nuclear Information System (INIS)
The changed political situation and recognition of the acute destruction of the natural environment in Poland have caused a series of actions aimed at preventing further deterioration of Polish environment. One of the most important events which took place in the last few years was the enactment by the Polish Parliament in May 1991 of the Act on the National Ecological Policy. The basic assumption of the new environmental policy is a declaration that sustainable development will in future direct economic development in Poland. The aim of the presented paper is to introduce existing policy of air protection and instruments which have been implemented to protect the air. Special attention is paid to legislation instruments, introduction and enforcement of proper economic mechanisms strengthening air protection and foreign policy aiming at increasing foreign assistance for this objective. Pollutants involved include sulfur dioxide, nitrogen ...
1995-06-26
Policy instruments to meet fisheries management objectives in Belgian fisheries
British Library Electronic Table of Contents (United Kingdom)
Although managing fisheries is complex, policymakers must make decisions daily that affect the future of aquatic resources. To make these decisions, they often combine a mental model with lessons learned from formal models such as computer models. While such computer models are frequently interpreted as predictors of the future, they are often more valuable when used as tools for learning about fisheries and options for management. This approach, looking at computer simulations as learning laboratories, is what this study is all about since its objective is to investigate by means of a microworld if policymakers in Belgian fisheries have the policy instruments at hand to align the real fisheries world with their often completely different desired fisheries worlds. This study illustrates ba...
2011-01-01
Neutrino tagging through secondary beam scraping
We discuss an experimental technique aimed at tagging electron neutrinos in multi-GeV artificial sources on an event-by-event basis. It exploits in a novel manner calorimetric and tracking technologies developed in the framework of the LHC experiments and of rare kaon decay searches. The setup is based on an instrumented decay tunnel equipped with tagging units that intercept secondary and tertiary leptons from the bulk of undecayed pi+ and protons. We show that the taggers are able to reduce the nue contamination originating from K_e3 decays by about one order of magnitude. Only a limited suppression (~60%) is achieved for nue produced by the decay-in-flight of muons; for moderate beam powers, similar performance as for K_e3 can be reached supplementing the tagging system with an instrumented beam dump.
2010-01-01
British Library Electronic Table of Contents (United Kingdom)
Background This study aimed to evaluate laparoendoscopic single-site (LESS) adrenalectomy via the retroperitoneal approach using the Alexis wound retractor with standard laparoscopic instrumentation. Methods Since October 2009, seven LESS retroperitoneal adrenalectomies have been completed successfully with a homemade single port created using an Alexis wound retractor as an access platform through a 3-cm incision beneath the tip of the 12th rib. Results All the LESS procedures for these seven patients with adrenal tumors (size, 1.3?6.0?cm; 4 right, 1 left) were completed successfully without traditional laparoscopic conversion or complication. The average operative time was 159?min, and the estimated blood loss was 100?ml. The average hospital stay was 2?days (range, 1?3?days). Conclusion...
2011-01-01
Instrumented model pile tests on sand plugs
Energy Technology Data Exchange (ETDEWEB)
0pen ended piles develop internal frictional resistance between the internal soil plug end the pile wall during axial loading. Current pipe pile design practice assumes that the ultimate internal skin friction is of the same order of magnitude as the outer skin friction. This paper describes a series of laboratory pile load tests on instrumented model pipe piles, designed to investigate the development of plug stresses and skin friction along the plug length during pile loading. The piles contain sand columns of various relative densities and of different heights. The soil plugs are loaded to failure under fully drained conditions. The test data indicate that internal skin friction in sand can be substantially higher than assumed in conventional design practice. This finding could lead to significant economical savings on future pipe pile foundations in sand.
1995-12-31
Energy Technology Data Exchange (ETDEWEB)
Fuji Electric has realized highly reliable and functional control systems by the dispersion type control system FOCUS, which uses the controller (ICS-2000) enjoying good reputation in controlling industrial plants for a long time and a personal computer with high windows operability, the former for controlling and the latter for MHI responsible for monitoring. The smelting process in a steel-making plant needs a highly reliable system for advanced control to ensure continuous operation. Fuji Electric delivered the FOCUS system to Kubota in 1998, as the smelting furnace instrumentation/control system for the cupola furnace. The system has been in service smoothly. Moreover, a total of four control systems have been delivered, 2 for steel-making furnaces and the other 2 for continuous casting. (NEDO)
1999-01-10
High Energy Neutrino Telescopes
This paper presents a review of the history, motivation and current status of high energy neutrino telescopes. Many years after these detectors were first conceived, the operation of kilometer-cubed scale detectors is finally on the horizon at both the South Pole and in the Mediterranean Sea. These new detectors will perhaps provide us the first view of high energy astrophysical objects with a new messenger particle and provide us with our first real glimpse of the distant universe at energies above those accessible by gamma-ray instruments. Some of the topics that can be addressed by these new instruments include the origin of cosmic rays, the nature of dark matter, and the mechanisms at work in high energy astrophysical objects such as gamma-ray bursts, active galactic nuclei, pulsar wind nebula and supernova remnants.
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
The energy dispersive beamline X6A at the National Synchrotron Light Source employs a curved crystal monochromator (polychromator) which focuses a range ([similar to]1 keV) of x-ray energies into a narrow (100--120 [mu]m) line image. Although this beamline was constructed primarily for time-dependent EXAFS experiments, we have begun to explore the use of this instrument for energy dispersive diffraction experiments with different types of sample including macromolecular crystals. The tunability ([ital E]=6.5 to 21 keV) and flexibility ([Delta][ital E]=100--1000 eV) of the instrument makes the beamline ideal as a test bed for the application of polychromatic single-crystal diffraction techniques to different chemical or biological materials.
1995-02-01
Development of electro-optical instrumentation for annular two-phase flow studies. [PWR
Energy Technology Data Exchange (ETDEWEB)
The development of new electro-optical instrumentation for studying the annular dispersed two-phase flow regime is described. The system measures the thickness of the water film and droplet size and velocity distributions which would be encountered in such a flow regime. The water film thickness is measured by an improved capacitance method with a short time constant using newly developed sensor electrodes. The electrodes are made flush with the inner wall of a cylindrical tube and do not disturb the flow. In the test equipment, steady, laminar flow of water along the inner wall of the tube is controlled by appropriate valves and a porous jacket while droplets are introduced by means of a special spray nozzle.
1981-05-01
Design on SDS2 on-line poison concentration monitoring in CANDU
Energy Technology Data Exchange (ETDEWEB)
At the reference plant (Wolsung unit No. 1) a manual poison sampling system is provided to periodically sample gadolinium from each tank and analyze it in the laboratory to provide assurance that adequate poison concentration in each tank is maintained. The AECB required a continuous, on-line monitoring system. On Wolsung unit No. 2, process piping adapter and new instrument loops added to the Liquid Injection Shutdown System(LISS) which is part of SDS2. The new instrument loops continuously monitor SDS2 poison conductivity and initiate an alarm when the poison concentration is too low. 8 refs., 1 fig. (author).
1996-10-01
Brookhaven National Laboratory Coastal Meteorology Program, 1972-1983
Energy Technology Data Exchange (ETDEWEB)
Research conducted at Brookhaven National Laboratory under the Coastal Meteorology and Diffusion Research Program from 1972 to 1983 is summarized by the following study areas: Diffusion Studies, Boundary Layer Studies, Coastal Meteorology Studies, Air-Sea Interaction Studies, Coastal Transport and Diffusion Climatology, Seabreeze Modeling and Instrument Development, all supported by the US Department of Energy. Studies supported by the Nuclear Regulatory Commission, the National Science Foundation and the American Petroleum Institute are also described. A summary of a Workshop on Coastal Atmospheric Transport Processes, an account of studies in progress, recommendations for future research and a description of facilities and instrumentation available are also included. A list of all publications and presentations prepared as part of the program is given with abstracts. 7 figures, 1 table.
1983-06-01
Atmospheric proton and deuterium energy spectra determination with the MASS2 experiment
Energy Technology Data Exchange (ETDEWEB)
The energy spectra of atmospheric-secondary protons and deuterium nuclei have been measured during the September 23, 1991, balloon flight of the NMSU/Wizard - MASS2 instrument. The apparatus was launched from Fort Sumner, New Mexico. The geomagnetic cutoff at the launch site is about 4.5 GV/c. The instrument was flown for 9.8 hours at an altitude of over 100,000 feet. Particles detected below the geomagnetic cutoff have been produced mainly by the interactions of the primary cosmic rays with the atmosphere. The measurement of cosmic ray energy spectra below the geomagnetic cutoff provide direct insights into the particle production mechanism and allows comparison to atmospheric cascade calculations.
1995-09-01
"Advanced" data reduction for the AMBER instrument
The amdlib AMBER data reduction software is meant to produce AMBER data products from the raw data files that are sent to the PIs of different proposals or that can be found in the ESO data archive. The way defined by ESO to calibrate the data is to calibrate one science data file with a calibration one, observed as close in time as possible. Therefore, this scheme does not take into account instrumental drifts, atmospheric variations or visibility-loss corrections, in the current AMBER data processing software, amdlib. In this article, we present our approach to complement this default calibration scheme, to perform the final steps of data reduction, and to produce fully calibrated AMBER data products. These additional steps include: an overnight view of the data structure and data quality, the production of night transfer functions from the calibration stars observed during the night, the correction of additional effects not taken into account in the standard ...
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
In this article the methodology followed to diagnose the performance of the equipment where heat is transferred from the feed water, condensate and circulation water systems in fossil power plants (FPP). The data collection is made with the unit in normal operation, using local instrumentation without taking the equipment out of service for its installation. The equipment diagnosis is made through the analysis of the collected data in actual operation and the design data; for this purpose a thermal balance of the interested systems is performed to obtain all the conditions an operation data. Later on the performance indicative parameters (PIP) of actual operation and design are calculated and compared one against the other. Such a comparison reveals the performance deterioration and the possible equipment faults. The data obtained and the supplementary information are stored in a data base whose objective is that Comision Federal de ...
1990-12-31
DoseWatchers - A computer based X ray dose monitoring project in paediatric radiology
International Nuclear Information System (INIS)
Full text: Introduction. Children, especially premature infants and neonates, are at a much higher risk to obtain an X ray induced disturbance of life - particularly cancer. On the one hand this is due to their longer life expectancy and on the other hand it is due to their higher cell proliferation rate. The paediatric radiology unit of the Inselspital Bern recently installed some of the most advanced X ray equipment nowadays available. It is based on the two latest digital technologies: double read computed radiography (CR) and direct digital radiography (DR). Only the implementation of these digital radiography systems permits the digital acquisition and additionally the analysis of acquired data. The systematic analysis of large amounts of biometric data and exposition data is the basis for further dose reduction and a systematic quality control (QC). Patients are increasingly critical concerning radiation exposure - especially parents ...
2006-11-13
The analysis of biological and environmental samples for lead by photon activation
International Nuclear Information System (INIS)
... activation analysis biological materials bremsstrahlung environment lead lead
STRESS ANALYSIS OF AN AUTOFRETTAGED LOOSE ...
... Title : STRESS ANALYSIS OF AN AUTOFRETTAGED LOOSE LINER FOR GUN BARREL CONSTRUCTION PRECOMPRESSED IN THE ...
1969-09-16
Radionuclide X-ray fluorescence analysis. 3: Examples of application in practice
Examples are given of the applicability and importance of radionuclide fluorescence analysis as a
1973-01-01
Determination of nanogram quantities of lead by photon activation analysis
International Nuclear Information System (INIS)
... activation analysis bremsstrahlung environment gamma spectroscopy
Waste monitoring system for effluents
Energy Technology Data Exchange (ETDEWEB)
The waste monitoring system in use at Los Alamos National Laboratory`s Plutonium Facility, TA-55, is a computer-based system that proves real-time information on industrial effluents. Remote computers monitor discharge events and data moves from one system to another via a local area network. This report describes the history, system design, summary, instrumentation list, displays, trending screens, and layout of the waste monitoring system.
1995-07-01
Visualization of liquid metal two-phase flow by a real time neutron radiography system
Energy Technology Data Exchange (ETDEWEB)
In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).
1995-11-01
Visualization of liquid metal two-phase flow by a real time neutron radiography system
International Nuclear Information System (INIS)
In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).
1995-01-01
Transmit-receive eddy current probes for heat exchanger inspection
International Nuclear Information System (INIS)
This paper describes various eddy current probes, and their performance, which were developed at the Chalk River Laboratories of Atomic Energy of Canada. Included are probes for detecting defects at tubesheet regions in heat exchanger tubes, defects at expansion-transition regions in finned tubes, and defects in ferromagnetic tubes. All of these probes can be used with conventional commercially available instruments. (author).
1987-09-01
Tracer distributions in the Tropical Lower Stratosphere.
Environmental Research Database
DescriptionMeasurements of halocarbons (CFCs and other halogen-containing compounds) in the tropical stratosphere will be made from a long duration MIR balloon. The balloon and instruments are capable of flying for three or more weeks in which time they will circum-navigate the globe. As the balloon rises each morning and falls each evening, measurements of halocarbons will be made every few hundred meters between about 20 and 30 km. In total it is hoped that over 40 such vertical profiles will be obtained [continued...
2009-01-31
The application of virtual instruments technique in U-H_2 experimental system
International Nuclear Information System (INIS)
The concept of the modern data acquisition system and some functional specialties of the programming software--Visual Basic 6.0 are introduced. The construction and theory of the hardware and the designing principle of the software are described. Experimental results showed that the real-time data acquisition rate was as high as 10 times per second in the system. And the relative standard uncertainty of the measurement was less than 0.5%. (authors)
2004-11-01
International Nuclear Information System (INIS)
Various diagnostics techniques for condition monitoring and life prediction of fluid power components and system are discussed. Though some of the techniques are very promising but may not be accepted because of increase in the instrumentation, it is planned to implement these techniques on various circuits of Fluid Power Lab for further improving and developing these for direct implementation in various fluid power circuits of power reactors. (author). 6 figs.
Structural material irradiations in FFTF
Energy Technology Data Exchange (ETDEWEB)
Information is presented concerning the Materials Open Test Assembly (MOTA); instrumentation and control system; MOTA neutronic data; pressurized tube specimens; stress-rupture measurements for reactor materials; miniature specimen design; the Interim Examination and Maintenance (IEM) cell at the FFTF; support services; and general information concerning the FFTF.
1985-01-01
Strategic pathways for energy in Brazil; Os caminhos da eficiencia energetica no Brasil
Energy Technology Data Exchange (ETDEWEB)
The aim of this work is to suggest steps and policies to increase the introduction of cost-effective energy in conservation measures in Brazil. This report first addresses the motivations for a policy of energy efficiency and summarizes experiences in Brazil. It then considers the roles and perspectives of the diverse agents and review the instruments of policy. It concludes with an overview of strategic needs and lines of action.
1995-01-01
Strain-gage for mining instruments
Energy Technology Data Exchange (ETDEWEB)
The proposed device incorporates an axle which has a roller bearing support mounted upon it. This support uses a cylindrical sleeve that comes in contact with the housing, the sensors, and the bearing support component. Metering accuracy is improved by placing roller bearing supports into grooves running through the protruding center sections of the sensor elements. These roller bearing supports interface with the cylindrical sleeve.
1982-01-01
Spreader Design for FERMI@Elettra Free Electron Laser
Energy Technology Data Exchange (ETDEWEB)
In this note we describe a conceptual design of a part ofthe electron beam delivery system for FERMI@Elettra free electron laser(FEL) located between the end of the linac and the entrance to the FEL.This part includes the emittance diagnostic section, the electron beamswitchyard for two FELs called spreader and matching sections. The designmeets various constrains imposed by the existing and planned buildingboundaries, desire for utilization of existing equipment and demands forvarious diagnostic instruments.
2007-01-18
Spectral characteristics of lignite open cast mining systems: a preliminary status
Energy Technology Data Exchange (ETDEWEB)
The application of a Compact Airborne Spectrographic Imager to assessment and monitoring of lakes in a lignite open cast mining area in central Germany is described. The imager was used in combination with additional ground experiments, such as field spectroscopy and water sampling. The spectral characteristics of an instrument under development for monitoring geochemical and hydrological processes are presented. Summary form only.
1999-07-01
Sources of X-rays in school; Zrodla promieniowania rentgenowskiego w szkole
Energy Technology Data Exchange (ETDEWEB)
Exposure of teachers of physics to X-radiation emitted by instruments which are used for demonstrating rarefied gas discharges during physics lessons at secondary schools is discussed. The measurements performed provide an explicit evidence that an effective, annual exposure dose under the most unfavorable conditions does not exceed admissible levels according to Polish regulations pertaining to persons non-occupationally exposed to ionizing radiation. (author). 3 refs,1 fig.
1996-12-31
... This is an amount less that the measurement accuracy of even the best meteorological instruments . So, is it really worth committing to 40 years of drastic carbon emissions reductions (which necessarily involves increasing the cost of hydrocarbon fuels in order to reduce fuel consumption, and force an industry-wide conversion to much more expensive alternative energy sources), all so that after nearly all of us are ...
Resonant-mass detectors of gravitational radiation
International Nuclear Information System (INIS)
A network of second-generation low-temperature gravitational radiation detectors is nearing completion. These detectors, sensitive to mechanical strains of order 10"-"1"8, are possible because of a variety of technical innovations that have been made in cryogenics, low-noise superconducting instrumentation, and vibration isolation techniques. Another five orders of magnitude improvement in energy sensitivity of resonant-mass detectors is possible before the linear amplifier quantum limit is encountered. 33 references, 3 figures, 1 table.
1987-07-01
Remote sensing of mine waste. Information Circular/1987
Energy Technology Data Exchange (ETDEWEB)
The report summarizes five separate Bureau of Mines contract studies on the use of aerial photogrammetry, satellite transmission of in situ instrumentation information, and satellite imagery to monitor and update mine waste embankment data. The equipment used, methods applied, results, recommendations, and cost analyses are presented along with a bibliography of related investigations.
1987-01-01
Remote sensing for environmental monitoring and resource management. Volume 2
Energy Technology Data Exchange (ETDEWEB)
The subject of this volume is remote sensing for environmental monitoring and resource management. This session is divided in eight parts. First part is on general topics, methodology and meteorology. Second part is on geology, environment and land cover. Third part is on disaster monitoring. Fourth part is on operational status of remote sensing. Fifth part is on coastal zones and inland waters. Sixth and seventh parts are on forestry and agriculture. Eighth part is on instrumentation and systems. (A.B.). refs., figs., tabs.
1992-12-31
Regulatory experience on safety system instrument uncertainty of Wolsong units
International Nuclear Information System (INIS)
This paper presents the regulatory experience gained from Wolsong Units 2,3 and 4 - Special Safety System Instrumentation Uncertainty for Trip Setpoint and Allowable Values. The equipment diversity method for the defense against common mode failure was applied to the transmitters of shutdown system number 2. However the Units experienced an unexpected drift problem with which the performance did not meet the Technical Specification (Tech Spec) Surveillance Requirements (SR). Discussed are the background, status and corrective actions, regulatory positions and issues to be solved for the drift problem. It was an instrument uncertainty methodology that the designer of safety system should have shown when the drift problem occurred. For deeper understanding of the problem, we present the background of Tech Spec SR for setpoints in Korean PWR and in CANDU reactors. The Setpoint Verification Test(SVT) and Calibration Test(CT) shall be achieved by ...
2001-05-01
International Nuclear Information System (INIS)
In the first part of this contribution, the definition of reference values is given and the theoretical and practical problems in the application of this concept are discussed. In this connection, the present resources on instrumentation and the technical requirements for dose assessment are described. In the second part, some consequences are taken and proposals for further actions are made. (orig.)
Quality assurance requirements for nuclear power plants in Hungary
International Nuclear Information System (INIS)
In Hungary, legislation for nuclear power plants was developed at the end of the 1970s, among which is the quality assurance code for nuclear power plants. Hungarian practice is presented, including discussion of the requirements for quality assurance, qualification of the suppliers and inspection practices. The general requirements of quality assurance in the course of construction of a nuclear power plant are presented: quality assurance of technological equipment, fuel, electrical equipment, automatic instrumentations, building structures and technology.
Energy Technology Data Exchange (ETDEWEB)
This book includes the latest developments and covers pump performance, selection and operations, materials, seals and packings, effective fluid characteristics, filtration, piping systems, economics, valves, instrumentation, automatic controls, power transmission equipment, pump and pipeline heating, and more. An extensive data section contains formulas, charts, symbols, nomographs, and standard specification documents.
1984-01-01
Progress at LAMPF. Progress report, January-December 1985
Energy Technology Data Exchange (ETDEWEB)
Research performed at LAMPF during 1985 is reported in the areas of: nuclear and particle physics; atomic and molecular physics; materials science; radiation-effects studies; biomedical research and instrumentation; nuclear chemistry; radioisotope production; and physics theory. Also reported are the status of LAMPF-II, facility development work, and accelerator operations. (LEW)
1986-05-01
P and e identification capabilities CAPRICE
Energy Technology Data Exchange (ETDEWEB)
The cosmic antiparticle ring imaging Cherenkov experiment (CAPRICE) flew on a stratospheric balloon 8-9 August 1994 over northern Canada and collected data for more than 21 hours with less than 5 g/cm{sup 2} of residual atmosphere. The instrument includes a solid radiator RICH detector and an electromagnetic calorimeter for particle identification in the magnetic spectrometer. Preliminary antiproton and positron identification capabilities are presented.
1995-09-01
New safety device announced for nuclear power plants
International Nuclear Information System (INIS)
An Ottawa-based company, ECS-Power Systems Inc., has successfully completed a series of tests on an innovative device called a hydrodynamic port (HDP), which makes it possible to automatically initiate and maintain emergency cooling of a nuclear reactor core by natural processes, without relying in any way on human intervention, instrumentation, electric power, valves or moving parts of any kind.
Nel tunnel alla ricerca di una nuova fisica
The Large Hadron Collider is at the top of world-wide science for particle physics. It promises to open the road to a new knowledge of the universe and its nature. Luciano Maiani and Robert Aymar, actual and future Director Generals of CERN, explain the aims of this most powerful instrument, the difficulties and the industrial repercussions, among which will be the "Grid", that will change the telecommunications (4 pages)
2003-01-01
Multi-mirror system, 2. Application of inverse Compton Scattering for lithography X-ray sources
Energy Technology Data Exchange (ETDEWEB)
A brilliant X ray source is proposed for lithography instruments with use of a multi-mirror system. The inverse Compton scattering between the stored electron beam in the storage ring and the stored photon beam in the multi-mirror system, is applied for the X-ray generation. (author)
2000-07-01
Merged Sounding Value-Added Product
Energy Technology Data Exchange (ETDEWEB)
The Merged Sounding value-added product (VAP) uses a combination of observations from radiosonde soundings, the microwave radiometer (MWR), surface meteorological instruments, and European Centre for Medium-Range Weather Forecasts (ECMWF) model output with a sophisticated scaling/interpolation/smoothing scheme in order to define profiles of the atmospheric thermodynamic state at one-minute temporal intervals and a total of 266 altitude levels.
2010-03-03
Irradiation test program for FFTF
International Nuclear Information System (INIS)
Four unique deisgn features are described which make the Fast Flux Test Facility eminently suitable for irradiation test programs. These features are a fast flux level of 7 x 10"1"5 neutrons/cm"2/sec, a 36-inch reference (breeder reactor) core height, test volumes suitable for testing of statistical quantities of materials, and the capability for direct (contact) or indirect (proximity) instrumentation of active core experiments.
Energy Technology Data Exchange (ETDEWEB)
An animated test is made for mice with malignant tumors irradiated by a self-made millimetre wave radiator for medical purpose. It is observed that S-180 sarcomas in mice after irradiation has been distinctly suppressed. And remarkable effects are shown through a lot of clinical practices on peptic ulcer, skin-deep ulcer, acute and chromic soft tissue injuries etc.
1995-12-31
High-resolution primary ion beam probe for SIMS
Energy Technology Data Exchange (ETDEWEB)
High-brightness negative ion beams, especially O{sup -} beams, from a compact gaseous plasma source are studied to evaluate the suitability for high-resolution SIMS. Ion-optical calculations are made using the beam parameters from the new source. Results suggest that sub-100 nm spot with O{sup -} beam current of 10 pA is achievable. Beam focusing, the resulting beam current distributions at the target and the expected instrumental performance are discussed.
2004-06-15
Energy Technology Data Exchange (ETDEWEB)
This study intends to develop an efficient market design for the German electricity market, with particular regard to renewable energy sources. The German electricity market is disintegrated, i.e. market sectors are not coordinated by a central agency but by their own interactions. The first part of the investigation analyzes the interdependences of market sectors, while the second part will analyze funding instruments for renewable energy sources on this basis. (orig.)
2007-12-14
Final Report: Planetary Instrument Definition and Design Program (PIDDP) Support Project
Energy Technology Data Exchange (ETDEWEB)
The results of Sandia National Laboratories' participation in the NASA Planetary Definition and Design Program are summarized. Areas reported include the characterization of large area cadmium zinc telluride spectrometers and the application of simulation techniques to the prediction of device performance. Also investigated was the response of mercuric iodide devices in the region from 1 to 100 KeV. A literature study to determine the status or radiation damage measurements in room temperature semiconductor devices is also reported.
1999-03-01
FOCUS: time-of-flight spectrometer for cold neutrons at SINQ
Energy Technology Data Exchange (ETDEWEB)
The physical layout of the Time-Of-Flight spectrometer at the new spallation source SINQ is presented. The concept shows up a hybrid-TOF combining a Fermi-chopper with a crystal monochromator. The demand of a versatile and flexible instrument for several applications is taken into account by the option of switching from time-focusing to monochromatic focusing mode such that the spectrometer can be optimised for both quasielastic and inelastic scattering applications. (author) 5 figs., 2 tabs., 16 refs.
1996-11-01
EMS and evaluation of environmental aspects: a review
International Nuclear Information System (INIS)
The Environmental Management System (EMS) is an instrument to manage the interaction between the organization and the environment. The scope od EMS is to reduce the environmental impact and to achieve improvements in overall performances. In particular, the focus point of EMS implementation is the method for identifying and assessing significant environmental aspects. This paper presents a review of methods and techniques existing in this area, and the definition of the state of the art. The results of the literature, regulation and case studies reviews have shown that rigorous, repeatable and transparent methodologies do not exist.
2006-04-01
Dosimetry in dental radiology. Dentascan spiral CT versus panoramic radiography
International Nuclear Information System (INIS)
The study compares the doses absorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations.
1999-05-01
Disk's Spiral Arms Point to Possible Planets
National Aeronautics and Space Administration (NASA)
Simulations of young stellar systems suggest that planets embedded in a circumstellar disk can produce many distinctive structures, including rings, gaps and spiral arms. This video compares computer simulations of hypothetical systems to an image of system SAO 206462 taken by the Subaru Telescope and its HiCIAO instrument. n nCredit: NASA Goddard Space Flight Center/NCSA
2011-10-18
Core power distribution measurement and data processing in Daya Bay Nuclear Power Station
International Nuclear Information System (INIS)
For the first time in China, Daya Bay Nuclear Power Station applied the advanced technology of worldwide commercial pressurized reactors to the in-core detectors, the leading excore six-chamber instrumentation for precise axial power distribution, and the related data processing. Described in this article are the neutron flux measurement in Daya Bay Nuclear Power Station, and the detailed data processing.
Considerations for the next Compton telescope mission
International Nuclear Information System (INIS)
A high resolution Compton telescope has been identified by the Gamma Ray Astronomy Program Working Group (GRAPWG) as the highest priority major mission in gamma ray astrophysics following GLAST. This mission should provide 25-100 times improved sensitivity, relative to CGRO and INTEGRAL, for MeV gamma ray lines. It must have good performance for narrow and broad lines and for discrete and diffuse emissions. Several instrumental approaches are being pursued to achieve these goals. We discuss issues relating to this mission including alternative detector concepts, instrumental configurations, and background reduction techniques. We have pursued the development of position-sensitive solid-state detectors (Ge, Si) for a high spectral resolution Compton telescope mission. A #approx#1 m2 germanium Compton telescope of position-sensitive germanium detectors was the basis for one of the GRAPWG concepts. Preliminary Monte Carlo estimates for the ...
2000-04-12
The non-invasiveness of autofluorescence technology may reduce sampling error and time delay for histopathology diagnosis. We establish biophotonic methods and guidelines to visualize and interpret early epithelial tissue changes that signify disease. Flexible and rigid fiber endomicroscopy instrumentation design parameters feasible for translation towards clinical use are in development.
2010-12-01
This report is a compilation of the Chalk Point surface weather and ambient atmospheric profile data for the months of September to December 1975. The atmospheric profiles were made using rawinsonde instrumentation. The compilation includes the 0700 EST d...
1976-01-01
Building a sustainable energy system
Energy Technology Data Exchange (ETDEWEB)
The inevitability of sustainable economic development and its linkage to a gradual shift to renewable energy sources, especially solar energy, was discussed. Means to measure sustainability of technology were described, and policy instruments (essentially research, development and demonstration, and punitive taxes on conventional energy carriers) to accelerate the shift to renewable energy sources were outlined.
1995-12-31
Application of remote sensing for coal waste embankment monitoring
Energy Technology Data Exchange (ETDEWEB)
The Bureau of Mines has two projects in the remote sensing field as it pertains to mining. One of these is a completed contract that studied the use of aircraft mounted cameras and the results of photogrammetry. The second project is an ongoing contract to study the effectiveness of using an instrumentation system wired to remote data collection station to record embankment data. 6 refs.
1981-01-01
An ultrasonic goniometer for surface stress measurement
An instrument has been constructed for the measurement of residual stress in steel. If necessary, large objects can be examined in situ. An account is given of the principles and construction. A special stressing frame provides for calibration. An application to residual stress in gear blanks has established a systematic variation of surface stress with nickel content and confirmed the overall effect of the surface hardening treatment.
1978-09-01
An Alternative for Assessing Problem-Solving Skills: The Overall Test.
Three studies were conducted on the validity of instruments adopted for student assessment in problem-based learning at the Maastricht School of Economics and Business Administration (the Netherlands). Results with 109 students suggest the importance of the breadth and depth of the student's knowledge profile and the extent to which the knowledge is usable. (SLD)
1996-12-01
International Nuclear Information System (INIS)
The Joint Convention on the Safety of Spent Fuel management and on the Safety of Radioactive Waste Management is the first legal instrument to directly address the safety of spent fuel and radioactive waste management on a global scale. The Joint Convention entered into force in 2001. This paper describes its process and its main achievements to date. The perspectives to establish of a Global Waste Safety Regime based on the Joint Convention are also discussed. (authors)
Absolute fission rates in the FFTF
Energy Technology Data Exchange (ETDEWEB)
The part of the FFTF Reactor Characterization Program reported in this paper is a measurement of absolute fission rates of eight major fuel isotopes at two different positions within the reactor. The instruments employed in these tests were fission ionization chambers for which the absolute efficiency and fissionable deposit mass assay have been rigorously established.
1981-06-01
2015 Plan. Project 1: methodology and planning process of the Brazilian electric sector expansion
International Nuclear Information System (INIS)
The Planning Process of Brazilian Electric Sector Expansion, their normative aspects, instruments, main agents and the planning cycles are described. The methodology of expansion planning is shown, with the interactions of several study areas, electric power market and the used computer models. The forecasts of methodology evolution is also presented. (C.G.C.).
SPARSE SUPERPIXEL UNMIXING FOR EXPLORATORY - NASA
Fast automated analysis of hyperspectral imagery can inform ... hyperspectral image analysis. .... atmospheric correction with the Crism Analysis Tool [11]. ...
Proteinortho: Detection of (Co-)orthologs in large-scale analysis
UK PubMed Central (United Kingdom)
BackgroundOrthology analysis is an important part of data analysis in many areas of bioinformatics such as comparative genomics and molecular phylogenetics. The ever-increasing flood...Full Text Available
UK PubMed Central (United Kingdom)
This article proposes Bayesian analysis of mediation effects. Compared to conventional frequentist mediation analysis, the Bayesian approach has several advantages. First, it allows researchers...Full Text Available
2009-12-01
Winter study of power plant effects
Energy Technology Data Exchange (ETDEWEB)
As a part of DOE's Meteorological Effects of Thermal Energy Releases (METER) program a field study was undertaken at the Bowen Electric Generating Plant (Plant Bowen) in December 1979. The study was a joint endeavor of Battelle Pacific Northwest Laboratories (PNL), Pennsylvania State University (PSU), and Oak Ridge National Laboratory (ORNL) with the main objective of determining the effects of the plant's smokestack effluents on aerosol characteristics and precipitation chemistry. Other objectives included studies of cooling tower temperature and humidity (T/h) plumes and drift drop concentrations. Conducted over a period of three weeks, the study involved an instrumented aircraft, pilot balloons, a tethered balloon system, a dense network of wetfall chemistry collectors and numerous ground- and tower-based meteorological instruments. Rainfall samples collected during the precipitation event of December 13, 1979, revealed ...
1980-10-01
Energy Technology Data Exchange (ETDEWEB)
A procedure and software have been developed to transform the area distribution of the residual surface heights available from the measurement with the Micromap interferometric microscope into a two-dimensional (2D) power spectral density (PSD) distribution of the surface height. The procedure incorporates correction of one of the spectral distortions of the PSD measurement. The distortion appears as a shape difference between the tangential and sagittal PSD spectra deduced from the 2D PSD distribution for an isotropic surface. A detailed investigation of the origin of the anisotropy was performed, and a mathematical model was developed and used to correct the distortion. The correction employs a modulation transfer function (MTF) of the detector deduced analytically based on an experimentally confirmed assumption about the origin of the anisotropy due to the asymmetry of the read-out process of the instrument's CCD camera. The correction function has only ...
2005-05-12
Satellite CMB anisotropy missions and new generation of balloon-borne and ground experiments, make use of complex multi-frequency instruments at the focus of a meter class telescope. Between 70 GHz and 300 GHz, where foreground contamination is minimum, it is extremely important to reach the best trade-off between the improvement of the angular resolution and the minimization of the straylight contamination mainly due to the Galactic emission. We focus here, as a working case, on the 30 and 100 GHz channels of the Planck Low Frequency Instrument (LFI). We evaluate the GSC introduced by the most relevant Galactic foreground components for a reference set of optical configurations. We show that it is possible to improve the angular resolution of 5-7% by keeping the overall GSC below the level of few microKelvin. A comparison between the level of straylight introduced by the different Galactic components for different beam regions is presented. ...
2003-01-01
The Magdalena Ridge Observatory 2.4 m Telescope
EOS Technologies has been commissioned to design and build a unique 2.4m astronomical telescope for the Magdalena Ridge Observatory. This telescope utilizes a high quality primary mirror and cell from a now decommissioned military application. This paper describes the project and gives an overview of the telescope design. The Magdalena Ridge Observatory (MRO) 2.4 meter telescope will be primarily utilized to observe, track, and characterize solar system astronomical targets, Earth satellites, space vehicles, and terrestrial military targets. The telescope's rapid tracking (slew rates are 10o/sec) will allow it to move to any target and acquire data within one minute of receipt of notice. In this way, the telescope will be used to capitalize on targets of opportunity that occur in asteroid studies (e.g., Near Earth Objects) and in astrophysics, such as gamma ray bursts and other transient phenomena. Planned instrumentation includes a CCD imager, and a ...
2006-07-01
Energy Technology Data Exchange (ETDEWEB)
Instrumentation research to study the feasibility of using optical data processing techniques to solve real-time pattern recognition problems for high energy physics experiments is now in its second year. During the past year, a prototype optical processor for use in BNL Experiment 702 was conceived and designed, using test data from the experiment and simulating the optical processor in the computer. A number of technical studies have been made, mostly relating to the selection of the optical filter for the processor. Comparisons between natural and synthetic holograms, both bleached and unbleached, have been made. We conclude from these tests that the kinoform, a computer-generated phase hologram, is the optimal choice for this processor. A new method for producing the kinoform has been tried by this group with encouraging results. The optical design for the prototype processor is complete, and the required optical elements, sources, and the detector have all ...
1982-01-01
Rotating magnetic tensor gradiometry and a superconducting implementation
International Nuclear Information System (INIS)
This work describes the theoretical basis for a new concept rotating magnetic tensor gradiometer. The rotating gradiometer consists of an approximately axial or transverse gradiometer which is made to rotate about a perpendicular axis so that the direction of sensitivity is continually changing. It is demonstrated for the first time that the rotation separates gradient components of progressively higher-order in the frequency domain and enables absolute-value measurements of all components of the first-order magnetic gradient tensor, even if the magnetic sensors comprising the gradiometer are intrinsically incapable of absolute-value detection. In addition, the rotating gradiometer concept has a number of other advantages: the gradiometer imbalance is no longer directly determined by the engineering precision, the DC and low-frequency performance of the instrument is not limited by the performance of the detectors in these respects, rotation at frequencies above ...
2009-07-01
Physics through the 1990s: scientific interfaces and technological applications
Energy Technology Data Exchange (ETDEWEB)
The volume examines the scientific interfaces and technological applications of physics. Twelve areas are dealt with: biological physics--biophysics, the brain, and theoretical biology; the physics-chemistry interface--instrumentation, surfaces, neutron and synchrotron radiation, polymers, organic electronic materials; materials science; geophysics--tectonics, the atmosphere and oceans, planets, drilling and seismic exploration, and remote sensing; computational physics--complex systems and applications in basic research; mathematics--field theory and chaos; microelectronics--integrated circuits, miniaturization, future trends; optical information technologies--fiber optics and photonics; instrumentation; physics applications to energy needs and the environment; national security--devices, weapons, and arms control; medical physics--radiology, ultrasonics, NMR, and photonics. An executive summary and many chapters contain recommendations ...
1986-01-01
Obstacle-induced perturbations on turbulent quantities measured in airflows over the sea
Energy Technology Data Exchange (ETDEWEB)
An experimental campaign, aiming to investigate the perturbation effects induced by fixed obstacles on turbulence measurements in airflows at the air-sea interface, was carried out at the marine platform of the Italian Navy, located in the harbour of La Spezia (North Ligurian Sea, Italy) on 28., 29., and 30. June 1994. This study was prompted by the ever-growing interest in more reliable estimates of energy, mass, and momentum exchanges between water surfaces and atmosphere, whose measurements are severely limited by the geometrical constraints of floating or fixed platforms where they are installed. Two types of meteorological instruments have been used: fast response (20 and 21 Hz) ultrasonic anemometers and fluxmeters to measure turbulent momentum, sensible, and latent heat fluxes and slow-response sensors (less than 4 Hz and sampled at a rate of 10{sup 2} Hz) to measure average wind and temperature vertical profiles in the perturbed boundary layer. Both fast- ...
1998-07-01
Nuclear incident monitor criticality alarm instrument for the Savannah River Site: Technical manual
Energy Technology Data Exchange (ETDEWEB)
The Savannah River Site is a Department of Energy facility. The facility stores, processes, and works with fissionable material at a number of locations. Technical standards and US Department of Energy orders, require these locations to be monitored by criticality alarm systems under certain circumstances. The Savannah River Site calls such instruments Nuclear Incident Monitors or NIMs. The Sole purpose of the Nuclear Incident Monitor is to provide an immediate evacuation signal in the case of an accidental criticality in order to minimize personnel exposure to radiation. The new unit is the third generation Nuclear Incident Monitor at the Savannah River Site. The second generation unit was developed in 1979. It was designed to eliminate vacuum-tube circuits, and was the first solid state NIM at SRS. The major design objectives of the second generation NIM were to improve reliability and reduce maintenance costs. Ten prototype units have been built and tested. This ...
1996-05-21
Kepler Mission Stellar and Instrument Noise Properties
Kepler Mission results are rapidly contributing to fundamentally new discoveries in both the exoplanet and asteroseismology fields. The data returned from Kepler are unique in terms of the number of stars observed, precision of photometry for time series observations, and the temporal extent of high duty cycle observations. As the first mission to provide extensive time series measurements on thousands of stars over months to years at a level hitherto possible only for the Sun, the results from Kepler will vastly increase our knowledge of stellar variability for quiet solar-type stars. Here we report on the stellar noise inferred on the timescale of a few hours of most interest for detection of exoplanets via transits. By design the data from moderately bright Kepler stars are expected to have roughly comparable levels of noise intrinsic to the stars and arising from a combination of fundamental limitations such as Poisson statistics and any instrument noise. The ...
2011-01-01
Interim cryo-cooler/detector report
Energy Technology Data Exchange (ETDEWEB)
This report describes development of an electronic system designed to reduce vibration generated by a cryocooler. The diminished vibration makes it practical to use the active cooler to extract heat from a portable gamma ray detector instrument. The system was developed for a Sunpower cryocooler with an integrated counterbalance mass. The overall momentum cancellation approach is also applicable to other similar cryocoolers. The cancellation system is an assembly of several components tailored to accomplish the required vibration reduction with minimum power consumption and volume. It is designed to be powered by a 18--32 Volt battery. Up to ten harmonics of the 58.65 Hz drive frequency are controlled. In addition to the vibration cancellation, the electronic system produces the drive signal for the cryocooler and regulates the cooler temperature. The system employs a sinusoidal drive to reduce the amount of higher harmonic vibration. A digital signal processor ...
1995-04-19
Fuel spray evolution; Comparison of experiment and CFD simulation of nonevaporating spray
Energy Technology Data Exchange (ETDEWEB)
Detailed spray characteristics were obtained for a small-capacity, pressure-swirl atomizer using an Aerometrics phase-Doppler particle analyzer. Measurements included drop size and velocity distributions, liquid volume fluxes, and air velocities at four axial locations, 25,50,75, and 100 mm, with complete radial traverses at each location. Drop size results were compared with measurements from a Malvern laser-diffraction instrument, and integrated liquid volume fluxes were compared with measured flow rates to estimate measurement uncertainties. Drop sizes measured by the two independent techniques and area-weighted-averaged over the radial traverses at each of the four axial stations varied on average by less than 4 percent. Integrated volume flux measurements by the phase-Doppler instrument at four axial stations differed from the nozzle flow rate by at most 19 percent, with some of the difference due to evaporation. The phase-Doppler data ...
1989-01-01
Flight Performance of the AKARI Cryogenic System
We describe the flight performance of the cryogenic system of the infrared astronomical satellite AKARI, which was successfully launched on 2006 February 21 (UT). AKARI carries a 68.5 cm telescope together with two focal plane instruments, Infrared Cameras (IRC) and Far Infrared Surveyor (FIS), all of which are cooled down to cryogenic temperature to achieve superior sensitivity. The AKARI cryogenic system is a unique hybrid system, which consists of cryogen (liquid helium) and mechanical coolers (2-stage Stirling coolers). With the help of the mechanical coolers, 179 L (26.0 kg) of super-fluid liquid helium can keep the instruments cryogenically cooled for more than 500 days. The on-orbit performance of the AKARI cryogenics is consistent with the design and pre-flight test, and the boil-off gas flow rate is as small as 0.32 mg/s. We observed the increase of the major axis of the AKARI orbit, which can be explained by the thrust due to thermal ...
2007-01-01
Exploring Quantum Gravity with Very-High-Energy Gamma-Ray Instruments - Prospects and Limitations
Some models for quantum gravity (QG) violate Lorentz invariance and predict an energy dependence of the speed of light, leading to a dispersion of high-energy gamma-ray signals that travel over cosmological distances. Limits on the dispersion from short-duration substructures observed in gamma-rays emitted by gamma-ray bursts (GRBs) at cosmological distances have provided interesting bounds on Lorentz invariance violation (LIV). Recent observations of unprecedentedly fast flares in the very-high energy gamma-ray emission of the active galactic nuclei (AGNs) Mkn 501 in 2005 and PKS 2155-304 in 2006 resulted in the most constraining limits on LIV from light-travel observations, approaching the Planck mass scale, at which QG effects are assumed to become important. I review the current status of LIV searches using GRBs and AGN flare events, and discuss limitations of light-travel time analyses and prospects for future instruments in the gamma-ray domain.
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
The fluxes of atmospheric electrons, positrons, positive and negative muons and negative pions have been determined using the NMSU Wizard-MASS2 balloons-borne instrument. The instrument was launched from Fort Sumner, New Mexico, (geomagnetic cut-off about 4.5 GV/c) on september 23, 1991. The flight lasted 9.8 hours and remained above 100.000 ft. Muons and negative pions were observed and their momenta were determined. Since these particles are not a part of the primary component, the measurement of their fluxes provides information regarding production and propagation of secondary particles in the atmosphere. Similarly, observations of electrons and positrons well below the geomagnetic cut-off provides insight into electromagnetic cascade processes in the upper atmosphere. In addition, the determination of the energy spectra of rare particles such as positrons can be used for background subtraction for cosmic ray experiments gathering data ...
1995-09-01
DOE personnel neutron dosimetry evaluation and upgrade program
Energy Technology Data Exchange (ETDEWEB)
The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. An Effective Dose Equivalent System is ...
1988-10-01
Energy Technology Data Exchange (ETDEWEB)
The task of designing high performance X-ray optical systems requires the development of sophisticated X-ray scattering calculations based on rigorous information about the optics. One of the most insightful approaches to these calculations is based on the power spectral density (PSD) distribution of the surface height. The major problem of measurement of a PSD distribution with an interferometric and/or atomic force microscope arises due to the unknown Modulation Transfer Function (MTF) of the instruments. The MTF characterizes the perturbation of the PSD distribution at higher spatial frequencies. Here, we describe a new method and dedicated test surfaces for calibration of the MTF of a microscope. The method is based on use of a specially designed Binary Pseudo-random (BPR) grating. Comparison of a theoretically calculated PSD spectrum of a BPR grating with a spectrum measured with the grating provides the desired calibration of the ...
2007-08-01
This study looks at how education policies in colonial Korea changed over time in order to accommodate the needs of the colonial authorities during the period of Japanese colonial rule in Korea (1910-1945). The colonial experience can be divided into four different periods according to the four Educational Ordinances issued in 1911, 1922, 1938, and 1943 by the colonial government with each period corresponding to a historic event or context. The constitutive relevance of colonial discourse for an understanding of education can be found in the gradual transformation of the education sector in Korea under colonial rule. It is evident that Japanese colonial policy was inherently contradictory in principle and in practice. On the one hand it sought the assimilation of the Koreans, while on the other it maintained its discriminatory and exploitative practices. Such contradiction was obvious within the colonial education system. As the principal instrument of ...
2010-12-01
Energy Technology Data Exchange (ETDEWEB)
The implementation of satellite remote sensing data for monitoring anthropogenic pollution in the USSR is described. Space-based monitoring systems offer the opportunity to identify pollution sources, track the spread of pollutants on the surface and in the air, and characterize land use patterns that cause erosion. Furthermore, vegetation under attack by polluting agents can be recognized by color changes, and water pollution in lakes, coastal zones, and in rivers near industrial areas and ports can be measured for the total affected area. The data have thus far been taken with instrumentation on board the Salyut space station, the Meteor-Priroda satellite, and from the Landsat MSS scanner. It is noted that the transboarder transport of pollutants necessitates sharing data with agencies of other nations, and that a data base must be developed to define procedures and instrumentation for given pollutants, algorithms for processing the data, and ...
1983-01-01
The data set consists of the following: - Biochemical analysis of Deschampsia leaves and root; - Chromatographic Analysis of membrane lipids (lipid profile) ...
International Nuclear Information System (INIS)
... activation analysis gamma spectra mev range molybdenum molybdenum ores
Improved Mechanical Properties and Ozone Resistance of ...
... 31 5.4 FACTORIAL DESIGN STATISTICAL ANALYSIS..... ... resistance. o Factorial design statistical analysis gave the ...
1991-08-01
Determination of trace amounts of thallium and lead by photon activation analysis
International Nuclear Information System (INIS)
... activation analysis lead lead 203 lead 204 microanalysis nuclear reactions
Compressive and Shear Buckling Analysis of Metal Matrix ...
... Title : Compressive and Shear Buckling Analysis of Metal Matrix Composite Sandwich Panels Under Different Thermal Environments. ...
Coefficient of Variation Spectral Analysis: An Application to ...
... A major problem in the analysis of power spectral density measurements is distinguishing between narrowband spectral components of interest ...
1983-05-03
The use of Radioactive labeling in hemoglobin identification
International Nuclear Information System (INIS)
The basic approach to radioactive labeling techniques in hemoglobin identification consists of mixing 14C labeled normal carrier globin with 3H labeled unknown globin and carrying out the subsequent separations and purifications looking at the distribution of 3H and 14C radioactivity. This technique was devised to ascertain the amino acid substitution in Hb Indianapolis and was instrumental in solving the structure of Hb Vicksburg. It was also useful in determining the purity of gamma-chains from cultures of human and baboon erythroid progenitors. Another use of this technique would be in identifying aberrant peaks of radioactivity in chain separation chromatograms, such as ''pre-peaks''.
The full scope simulator hardware I/O realization in Daya bay nuclear power station
International Nuclear Information System (INIS)
The full scope simulator in Daya Bay Nuclear Power Station is imported from THOMSON-CSF company in France. It is a large facility, using digital simulation technology, that simulate the main control room of Daya Bay Nuclear Power Station with the high fidelity. It is used for training operators; system analyzing including operation procedure verification. The input output interface system of the simulator is the bridge of the information exchange between instrumentation and the computer. From the point of view of data transfer, this paper discusses the operation principle of the I/O interface system.
The GEOFLOW experiment missions in the Fluid Science Laboratory on ISS
The GEOFLOW I experiment has been successfully performed on the International Space Sta-tion (ISS) in 2008 in the Columbus module in order to study the stability, pattern formation and transition to turbulence in a viscous incompressible fluid layer enclosed in two concentric co-rotating spheres subject to a radial temperature gradient and a radial volumetric force field. The objective of the study is the experimental investigation of large scale astrophysical and geophysical phenomena in spherical geometry stipulated by rotation, thermal convections and radial gravity fields. These systems include earth outer core or mantle convection, differen-tial rotation effects in the sun, atmosphere of gas planets as well as a variety of engineering applications. The GEOFLOW I experimental instrument consists of an experiment insert for operation in the Fluid Science Laboratory, which is part of the Columbus Module of the ISS. It was first launched in February 2008 together ...
2010-01-01
Technology development tendency and R and D idea of NPP radiation monitoring system
International Nuclear Information System (INIS)
This paper gives a general description of functions, usages and system configurations of the instruments and their major units or components of the radiation monitoring system, as well as the status and technical gap between domestic and foreign technologies. And then the paper also puts forward an idea on product R and D, i.e. combination of independent R and D and innovation, assimilation and re-innovation of foreign advanced technology at present situation in order to keep pace with the rapid development of nuclear power in China and achieve the goal of localization of nuclear power equipment. (authors)
2009-06-01
Sustaining integrated technology in undergraduate mathematics
British Library Electronic Table of Contents (United Kingdom)
The effective integration of technology into the teaching and learning of mathematics remains one of the critical challenges facing contemporary tertiary mathematics. This article reports on some significant findings of a wider study investigating the use of technology in undergraduate mathematics. It first discusses a taxonomy developed to describe and compare technology use within individual courses and departments that identifies a complex range of factors, summarized under six defining characteristics of an integrated technology mathematics curriculum (ITMC). An instrument for a simple comparison of technology use employing the elements of this taxonomy is provided. It then presents evidence gathered from an observational study of technology implementation at The University of Auckland...
2011-01-01
Sample method for formation of nanometer scale holes in membranes
Energy Technology Data Exchange (ETDEWEB)
When nanometer scale holes (diameters of 50 to a few hundred nm) are imaged in a scanning electron microscope (SEM) at pressures in the 10{sup -5} to 10{sup -6} torr range, hydrocarbon deposits built up and result in the closing of holes within minutes of imaging. Additionally, electron beam deposition of material from a gas source allows the closing of holes with films of platinum or TEOS oxide. In an instrument equipped both with a focused ion beam (FIB), and an SEM, holes can be formed and then covered with a thin film to form nanopores with controlled openings, ranging down to only a few nanometers.
2003-02-24
Energy Technology Data Exchange (ETDEWEB)
A rocket borne experiment to measure the temperature structure of the inner solar corona via the doppler broadening of the resonance hydrogen Lyman-..cap alpha.. (lambda1216A) radiation scattered by ambient neutral hydrogen atoms was attempted during the 16 Feb 1980 solar eclipse. Two Nike-Black Brant V sounding rockets carrying instrumented payloads were launched into the path of the advancing eclipse umbra from the San Marco satellite launch platform 3 miles off the east coast of Kenya.
1981-01-01
Requirements and guidelines for NSLS experimental beam line vacuum systems: Revision A
Energy Technology Data Exchange (ETDEWEB)
Requirements are provided for NSLS beam line front ends and vacuum interlocks. Guidelines are provided for UHV beam line vacuum systems, including materials, vacuum hardware (pumps, valves, and flanges), acoustic delay lines and beam line fast valves, instrumentation, fabrication and testing, and the NSLS cleaning facility. Also discussed are the design review for experimenters' equipment that would be connected to the NSLS and acceptance tests for any beam line to be connected with the ring vacuum. Also appended are a description of the acoustic delay line as well as the NSLS vacuum standards and NSLS procedures. (LEW)
1986-10-01
Production of a helium beam in a focused ion beam machine using an electron beam ion trap
International Nuclear Information System (INIS)
Gallium liquid-metal ion sources that have been introduced in the late 1970s have allowed the development of a new class of micro- and nanofabrication tools collectively denominated as focused ion beam (FIB) machines. To investigate the potential of a helium beam in such a FIB instrument the authors have tested a room-temperature electron beam ion trap coupled with a high resolution FIB machine. In this letter they present their first results in target imaging using a helium beam with a resolution that allows to account for a beam diameter in the submicrometer range.
2007-02-19
Proceedings of the technical exchange meeting on passive radon monnitoring
International Nuclear Information System (INIS)
The purpose of the meeting was to bring together a number of scientists active in the development and use of passive radon monitoring instrumentation, primarily activated charcoal detectors and alpha track detectors. Many of those present expressed a desire to receive copies of the viewgraphs and other materials presented. Most have supplied extended abstracts or complete reports. These materials are reproduced here as a Technical Measurements Center Report for the benefit of those attending the meeting and for others interested in passive radon monitoring. Individual papers were processed separately for the data base.
1987-09-21
Energy Technology Data Exchange (ETDEWEB)
It is built and tested a transition radiation detector (TRD) to discriminate positrons from protons in the balloon flight TS 93 experiment. It is presented the TRD performance using flight data obtaining a proton-positron rejection factor of the order of 10{sup -3}. During the 24 hour flight, the data in the momentum range 4-50 GeV/c are collected. Using the TRD together with the Silicon calorimeter, it is achieved an overall rejection factor of about 10{sup -5} of positron against the proton background over the entire momentum range.
1995-09-01
Patient isolation in chronic benign pain.
Over the years, nurses, doctors and scientists have sought ways of assessing the impact of pain on patients. While many of the instruments devised have been extremely useful in identifying the nature and intensity of pain, defining the effect it has on people's lives and perceptions has proved much more problematic. Based on the work she carried out with patients suffering from chronic benign pain, Karen Rose explores one aspect of these effects--the feeling of isolation. By using a four-step anthropological approach to identify the impact of pain, she argues, nurses can arrive at a realistic and accurate assessment of how patients are coping. PMID:7947167
PBAR: A superconducting magnet spectrometer for cosmic ray antiproton studies
Energy Technology Data Exchange (ETDEWEB)
We describe the PBAR balloon-borne magnet spectrometer flown on August 13-14, 1987 to measure the abundance of cosmic ray antiprotons in the energy interval 100-1580 MeV at the top of the atmosphere. The limits first reported have been improved to an overall limit of anti p/p<2.0x10{sup -5} (85% CL). We summarize the overall design and performance of the PBAR spectrometer, which had the unique ability to establish the mass of each singly charged cosmic ray, as well as to reject spurious antimatter candidates caused by hard scatterings within the instrument. (orig.).
1990-09-15
Energy Technology Data Exchange (ETDEWEB)
This review of methods and designs of transducers for nondestructive determination of the magnitude and nature of the anisotropy of magnetic properties (permeability, induction, coercive force, energy loss due to magnetization reversal) in local portions of ferromagnetic sheet and, in some cases, in individual parts of products. The need to measure the anisotropy is considered for two angles: for the case when the anisotropy is due to the crystallographic texture and determines the main operating characteristics of widely used sheet such as electrical steel and automobile body sheet, and for crystallographically isotropic materials, in which the anisotropy of magnetic properties as a result of mechanical stresses is a measure for determining the internal stresses.
1995-04-01
Meterological Information System of the Karlsruhe Nuclear Research Center
Energy Technology Data Exchange (ETDEWEB)
The Meteorological Information System (MIS) comprising the meteorological instruments, the computers, and the software for data processing and recording, is part of the KfK safety and control system. In 1982 is was equipped with an independent data processing system. The report explains the arrangement and the operation of the sensors and thw two process computers. For selected meteorological situations the ability of the system is demonstrated, i.e., the presentation of the vertical profiles of wind, temperature and turbulence in the lower atmospheric boundary layer as well as the calculation and graphical representation of the transport and dispersion into the KfK environment of radioactive pollutants being released by the nuclear installations of the KfK into the atmosphere.
1984-01-01
Energy Technology Data Exchange (ETDEWEB)
Staff exchanges, such as the one described in this report, are intended to facilitate communication and collaboration among scientists and engineers at DOE laboratories, in US industry, and academia. During the past 5 years, PNL has developed prototype instrumentation to automate the data collection required for electrochemical determination of corrosion rates and behavior of materials in various electrically conductive environments. The last version is labeled the Sentry 100 prototype corrosion data scanner. Applications include these in the pulp and paper industry and at hazardous waste sites.
1995-04-01
Intermediate scale borehole (Room C): In situ data report (January 1989--June 1993)
Energy Technology Data Exchange (ETDEWEB)
Data are presented from the intermediate scale borehole test, an in situ test fielded in the pillar separating Rooms C1 and C2 at the Waste Isolation Pilot Plant (WIPP). The test was to provide data on the influence of scale, if any, on the structural behavior of underground openings in salt. These data include selected fielding information, test configuration, instrumentation activities, and comprehensive results from a large number of gages. Construction of the test began in December 1989, with the drilling of the intermediate scale borehole in December 1990. Gage data in this report cover the period from January 1989 through June 1993.
1994-11-01
Instrumentation, controls and automation in the power industry. Volume 45
Energy Technology Data Exchange (ETDEWEB)
Sessions covered economic and management, advance control technologies (including pulverized coal dynamic balancing-activator and control strategy by B. DeMarcy and X.Ollat), nuclear technologies, environmental (including purge considerations for seasonal SCR systems by D.P. Evely, NOx and heat rate supervisory control at NRG-Huntley operations by G Lange, comparison of gypsum dewatering technologies at flue gas desulfurization plants by B.A. Perlmutter, beta gauge particulate monitoring by J.L. Arnold), improving performance at nuclear power plants, network security, and emerging applications.
2002-07-01
Initial results from 50mm short SSC dipoles at Fermilab
Energy Technology Data Exchange (ETDEWEB)
Several short model SSC 50 mm bore dipoles are being built and tested at Fermilab. Mechanical design of these magnets has been determined from experience involved in the construction and testing of 40 mm dipoles. Construction experience includes coil winding, curing and measuring, coil end part design and fabrication, ground insulation, instrumentation, collaring and yoke assembly. Fabrication techniques are explained and construction problems are discussed. Similarities and differences from the 40 mm dipole tooling and management components are outlined. Test results from the first models are presented. 19 refs., 12 figs.
1991-03-01
International Nuclear Information System (INIS)
The additional error in measurement of the thickness of Kh18N10T steel for possible changes in composition with an energy of the photons of ionizing radiation of 10-80 keV was evaluated. The desirability of use of a type REIS-I x-ray emitter in measurement of the thickness of steel up to 1 mm is shown. The instrument provides measurement of the thickness of steel in the 0.1-1.0 mm range with a reproducibility of the results with an error not exceeding 0.5-1.0%. The measurement error with corrugations characteristic of bellows does not exceed 5%.
Ground level cosmic ray observations
Energy Technology Data Exchange (ETDEWEB)
Cosmic rays at ground level have been collected using the NMSU/Wizard - MASS2 instrument. The 17-hr observation run was made on September 9. 1991 in Fort Sumner, New Mexico, Usa. Fort Sumner is located at 1270 meters a.s.l., corresponding to an atmospheric depth of about 887 g/cm{sup 2}. The geomagnetic cutoff is 4.5 GV/c. The charge ratio of positive and negative muons and the proton to muon ratio have been determined. These observations will also be compared with data collected at a higher latitude using the same basic apparatus.
1995-09-01
Gamma Radiation Detectors of the TA-55 Waste Line Monitoring System
Energy Technology Data Exchange (ETDEWEB)
This report covers the gamma detectors, measurement instrumentation, and testing results of a system developed at Los Alamos National Laboratory. This system monitors the process liquid waste streams at the Plutonium Facility (TA-55) for the presence of radioactive contamination. The detectors are at various points on the acid, caustic, and industrial waste lines. Two of the detectors are on the sanitary sewer lines from the facility. A custom interface unit associated with these two detectors furnishes the facility operation center with a notification of the detection of material. All of the detectors furnish measurement information to a central computer system for storage and trending.
1999-06-01
Energy policy: security of supply, sustainability and competition
Energy Technology Data Exchange (ETDEWEB)
The paper considers the main components of energy policy, in particular the challenges of network security of supply, long-term contracts and the environmental constraints. It is argued that the United Kingdom's energy policy should take account of multiple market failures and context dependent. Given energy liberalisation in the 1980s and 1990s, it is argued that interventions based upon market-based instruments should be given greater importance. Institutional reform to reflect the shift in focus towards investment in non-carbon technologies and the security issues associated with networks is proposed, notably the creation of an energy agency. 15 refs., 2 figs.
2002-02-01
International Nuclear Information System (INIS)
Mass spectrometry was instrumental in the discovery of the fullerenes and the characterization of their special structure (truncated icosahedron). High resolution and high sensitivity mass spectrometry in combination with a crossed molecular beam/electron beam ion source is used here to study a further, very unique property of singly and multiply charged fullerene ions (up to Z=7), i.e. their strong resilience towards decomposition via sequential C_2 evaporation and via Coulomb explosion, respectively. (author).
1994-03-20
Direct dark matter identification with a hybrid detection technique
In the quest to understand the ultimate nature of WIMPs, we propose the use of a hybrid detection technique: cylinders filled with liquefied noble gasses, acting as targets, are immersed inside a tank of Gd-doped ultra-pure water that provides an active and efficient veto against neutrons. The evaluation of the background rejection capabilities and physics potential of this instrument have been carried out through a full GEANT4 simulation, assuming the detector will be located at the Canfranc underground laboratory (in the Spanish Pyrenees). Our results compare very favourably with existing or planned experiments in the field. This technique is scalable and will allow to reach target masses of few tonnes in the next future.
2008-01-01
Development of a chemically assisted micro-beam etching system for three-dimensional microanalysis
Energy Technology Data Exchange (ETDEWEB)
A chemically assisted micro-beam etching system for 3D microanalysis was designed. Using chemically assisted ion beam etching (CAIBE) method with FIB shave-off scanning, about several hundred micrometers clean cross-section will be acquired in a few hours. We use focused ion beam (FIB) and electron beam (EB) as micro-beams, halogen or halide mainly as reactive gases. The apparatus was manufactured based on this concept. We found that the FIB, Q-MS and SED worked as expected. The instrumentation has been completed.
2003-01-15
Derivatives and their use in acquisition financing
Energy Technology Data Exchange (ETDEWEB)
Over the past decade, the energy {open_quotes}paper{close_quotes} market has grown into one of the largest traded markets in the world providing hedging instruments for the producer as well as the enduser of energy products. Because banks, stockholders, and other financial providers rely on a borrower`s ability to generate cash flow to repay their investment, borrowers are increasingly turning to the derivatives markets to provide security against one of the most volatile markets in he world. The existence of this market has enhanced the ability of financial institutions to lend with confidence and appropriate aggressiveness to the oil and gas industry.
1995-12-31
Database management system for instrument data management
Energy Technology Data Exchange (ETDEWEB)
Data from many measuring devices throughout the Savannah River Site (SRS) is transmitted to a central location for processing as a vital component in the SRS emergency preparedness and response program. The data processing is currently accomplished using VAX-based FORTRAN programs with the data stored in Digital's Record Management System (RMS) files which is shared using global COMMON. A program is underway to store and process this data using a Structured Query Language (SQL)-based Database Management System (DBMS). The advantages of replacing the current system with one using an SQL-based DBMS are discussed.
1990-01-01
Coal preparation plant condition-based maintenance
Energy Technology Data Exchange (ETDEWEB)
This report briefly describes the background to colliery engineering maintenance, past experience in machine condition monitoring within coal preparation and the introduction of condition-based maintenance. A role model scheme has been developed for the introduction of condition-based maintenance into coal preparation plants. The report describes the instrumentation and monitoring methods suitable for application to most mineral processing plants, the use of specialist companies to monitor, gather, process and analyse the information and the actions taken by the colliery. Examples of the benefits of operating such a scheme are given in terms of safety, performance and finance. Other problematical aspects of coal processing are examined which have a direct effect on plant condition and availability.
1998-12-31
CO2 CAPTURE BY ABSORPTION WITH POTASSIUM CARBONATE
Energy Technology Data Exchange (ETDEWEB)
The objective of this work is to improve the process for CO{sub 2} capture by alkanolamine absorption/stripping by developing an alternative solvent, aqueous K{sub 2}CO{sub 3} promoted by piperazine. Progress has been made in this reporting period on three subtasks. A simple thermodynamic model has been developed to represent the CO{sub 2} vapor pressure and speciation of the new solvent. A rate model has been formulated to predict the CO{sub 2} flux with these solutions under absorber conditions. A process and instrumentation diagram and process flow diagram have been prepared for modifications of the existing pilot plant system.
2002-10-01
The current and prospective status of astronomical research in Ukraine is discussed. A brief history of astronomical research in Ukraine is presented and the system organizing scientific activity is described, including astronomy education, institutions and staff, awarding higher degrees/titles, government involvement, budgetary investments and international cooperation. Individuals contributing significantly to the field of astronomy and their accomplishments are mentioned. Major astronomical facilities, their capabilities, and their instrumentation are described. In terms of the number of institutions and personnel engaged in astronomy, and of past accomplishments, Ukraine ranks among major nations of Europe. Current difficulties associated with political, economic and technological changes are addressed and goals for future research activities presented.
2005-01-01
Applications of infrared and Raman spectroscopy in industry
Energy Technology Data Exchange (ETDEWEB)
There have been many recent explosive advances in both IR and Raman spectroscopy which have developed in response to industrial problems of increasing complexity. Probably the biggest factor in these advances has been computerization, which has contributed not only to substantial improvements in data handling but to enormous gains in sensitivities of analyses as well. In this paper numerous examples of Raman and IR applications in industry are given using many of these recent advances, including in-situ techniques, microprobe analyses, unusual combinations of instruments - i.e., hyphenated methods - and new sample handling techniques. The bright future of FT-IR and Raman spectroscopy is also briefly discussed.
1986-07-01
Applications of X-ray scattering in pharmaceutical science
British Library Electronic Table of Contents (United Kingdom)
The use of X-ray scattering techniques in pharmaceutical science is increasing, in part through increased collaborations with the materials science community, and through increased availability of instrumentation, particularly synchrotron sources. The ability to understand not only the biopharmaceutical outcome, but also arguably, more importantly, the structural aspects of drugs and drug delivery systems, is essential to progressing pharmaceutical science; this review serves as an introduction to the major techniques and the wide range of areas in which X-ray scattering may be applied in understanding and controlling structure in pharmaceutical systems.
2011-01-01
Anesthetic considerations for nontransplant procedures in lung transplant patients
British Library Electronic Table of Contents (United Kingdom)
Lung transplantation has become an accepted option for many patients with end-stage pulmonary diseases. Anesthesia and surgery following lung transplantation may be required for various diseases that may affect both systemic organs and the transplanted graft. When a patient with a lung transplant undergoes surgery, there is the potential for interference with lung function, depending on the type of intervention and its anatomical site. Accurate preoperative evaluation, an understanding of the physiology of the transplanted lung, proper airway instrumentation, individualized management of intraoperative ventilation, and fluid balance are essential for a positive perioperative outcome.
2011-01-01
The MISR instrument aboard NASA's Terra satellite participated in the UAE-2 campaign, August-October 2004. This campaign represented a unique opportunity to study the complex aerosol situation in the Arabian Gulf region, in the context of a first-rate collection of aircraft and surface-based instruments, giving us the opportunity to do some groundbreaking satellite aerosol validation work. We aimed (1) to validate MISR aerosol retrieval results for dust and pollution particles over dark and light surfaces, and (2) to contribute regional maps of aerosol optical thickness (AOT) and particle micro-physical properties, giving spatial context to the field-instrument measurements, and moving toward a satellite-based regional aerosol climatology. The validation effort benefited from the combination of an instrumented aircraft and a regional network of surface-based sun photometers. We obtained high-quality ...
2005-12-01
A micro-compression study of shape-memory deformation in U-13at%Nb
Energy Technology Data Exchange (ETDEWEB)
Micro-compression specimens, 1O-15{mu}m in diameter by 20-30{mu}m in height, were produced from individual parent grains in a polycrystalline U-13at%Nb shape-memory alloy using the focused ion beam (FIB) technique. The specimens were tested in a nanoindentation instrument with a flat diamond tip to investigate stress-strain behavior as a function of crystallographic orientation. The results are in qualitative agreement with a single-crystal accommodation strain (Bain strain) model of the shape-memory effect for this alloy.
2008-01-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
