Enabling Technology for Monitoring & Predicting Gas Turbine Health & Performance in IGCC Powerplants
Energy Technology Data Exchange (ETDEWEB)
The ''Enabling & Information Technology To Increase RAM for Advanced Powerplants'' program, by DOE request, was re-directed, de-scoped to two tasks, shortened to a 2-year period of performance, and refocused to develop, validate and accelerate the commercial use of enabling materials technologies and sensors for coal/IGCC powerplants. The new program was re-titled ''Enabling Technology for Monitoring & Predicting Gas Turbine Health & Performance in IGCC Powerplants''. This final report summarizes the work accomplished from March 1, 2003 to March 31, 2004 on the four original tasks, and the work accomplished from April 1, 2004 to July 30, 2005 on the two re-directed tasks. The program Tasks are summarized below: Task 1--IGCC Environmental Impact on high Temperature Materials: The first task was ...
2005-12-01
Briefing Book, Interagency Geothermal Coordinating Council (IGCC) Meeting of April 28, 1988
Energy Technology Data Exchange (ETDEWEB)
The IGCC of the U.S. government was created under the intent of Public Law 93-410 (1974) to serve as a forum for the discussion of Federal plans, activities, and policies that are related to or impact on geothermal energy. Eight Federal Departments were represented on the IGCC at the time of this meeting. The main presentations in this report were on: Department of Energy Geothermal R&D Program, the Ormat binary power plant at East Mesa, CA, Potential for direct use of geothermal at Defense bases in U.S. and overseas, Department of Defense Geothermal Program at China Lake, and Status of the U.S. Geothermal Industry. The IGCC briefing books and minutes provide a historical snapshot of what development and impact issues were important at various time. (DJE 2005)
1988-04-28
A proposed scheme for coal fired combined cycle and its concise performance
Energy Technology Data Exchange (ETDEWEB)
For IGCC, the primary investment is too high due to the demand of high gasification efficiency. For PFBCC, the thermal efficiency is too low due to the relatively low turbine inlet temperature and the hot working medium of the gas turbine is not easy to clean. A new scheme is proposed for coal fired combined cycle to overcome the main drawbacks of IGCC and PFBCC. The research targets are developing a new cycle construction of coal fired combined cycle to raise the efficiency and reduce the primary investment. Actually, the new scheme is a synthesis of some existing proposals. It adopts partial gasification to reduce the primary investment of the gasification equipment. The un-gasified surplus solid is then fed to a pressurized fluidized bed boiler, but adopting Curtiss Wright type external combustion to lower the ash content in the working medium. The gas fuel from the partial gasifier is combusted in a top combustor to further increase the ...
2007-06-15
GREENHOUSE GAS EMISSIONS CONTROL BY OXYGEN FIRING IN CIRCULATING FLUIDIZED BED BOILERS
Energy Technology Data Exchange (ETDEWEB)
Given that fossil fuel fired power plants are among the largest and most concentrated producers of CO{sub 2} emissions, recovery and sequestration of CO{sub 2} from the flue gas of such plants has been identified as one of the primary means for reducing anthropogenic CO{sub 2} emissions. In this study, ALSTOM Power Inc. (ALSTOM) has investigated several coal fired power plant configurations designed to capture CO{sub 2} from effluent gas streams for use or sequestration. Burning fossil fuels in mixtures of oxygen and recirculated flue gas (made principally of CO{sub 2}) essentially eliminates the presence of atmospheric nitrogen in the flue gas. The resulting flue gas is comprised primarily of CO{sub 2}. Oxygen firing in utility scale Pulverized Coal (PC) fired boilers has been shown to be a more economical method for CO{sub 2} capture than amine scrubbing (Bozzuto, et al., 2001). Additionally, oxygen firing in Circulating ...
2003-05-15
The use of supplementary firing in an externally-fired combined cycle power plant
Energy Technology Data Exchange (ETDEWEB)
The most developed systems for the generation of electricity from coal are the Integrated coal Gasification Combined Cycle (IGCC) and the Pressurized Fluidized Bed Combustion (PFBC) system. They both represent state-of-the-art technology and provide electric power at 41-46% LHV efficiency. However, the high level of complexity leads to lower reliability and higher costs. A simpler system, based on a coal-fired steam boiler integrated with a gas turbine, has been proposed. In such a plant, known as the externally fired combined cycle (EFCC), compressed air is heated indirectly in a heat exchanger located in the coal furnace. The hot air is then expanded in a turbine, and the exhaust is passed on to the coal furnace as preheated combustion air. Steam produced in the boiler generates additional power in a steam turbine. The exclusion of coal combustion products from the gas turbine avoids hot gas clean-up and turbine blade corrosion by coal ash. ...
1997-12-31
Research and development of new coal based combined cycle power plant concept
Energy Technology Data Exchange (ETDEWEB)
Out of concern for the global environment, technologies for coal-fired combined cycle power generation are under development throughout the world today, aiming at highly efficient use of coal. Under these circumstances, the authors and others, with the intention of producing a coal-fired combined cycle power generation system with higher plant efficiency, lower construction cost, and higher reliability than conventional systems, proposed a new gasification combined cycle power generation system that differs from the conventional IGCC system. The authors studied system configuration and conducted elementary research necessary for implementing the system. This report deals with the basic concepts of the system and the results of basic studies carried out to realize of the concepts, including a study on alkali metal vapour concentration in relation to heat corrosion; the relation between gas de-dusting temperature and gas alkali metal vapour ...
1997-12-31
Air quality constraints to statewide power plant siting. Final staff report
Energy Technology Data Exchange (ETDEWEB)
The object of this study was to identify those areas in California where synthetic fuel-fired power plants could be sited in the 1990 time frame, from an air quality perspective. The synfuel-fired power plants considered in this new study were 500 Mw methanol-fired combined cycle (MFCC) and 500 Mw integrated gasifier combined-cycle (IGCC) units. For comparison purposes, 500 Mw direct coal-fired boilers and 500 Mw natural gas-fired combined-cycle units were also considered. Staff did not attempt to locate plants at any specific sites, but relied primarily upon a regional countywide analysis. The study provides an approximation, for planning purposes, of a reasonable limit of the state's power plant siting capacity, given the plant types and sizes, conditions, and assumptions specified. The study shows that local emission limitations often preclude ...
1980-11-01
Air quality constraints to statewide power plant siting
Energy Technology Data Exchange (ETDEWEB)
Those areas in California where synthetic fuel-fired power plants could be sited in the 1990 time frame, from an air quality perspective were identified. The synfuel-fired power plants considered in this new study were 500 MW methanol-fired combined cycle (MFCC) and 500 MW integrated gasifier combined-cycle (IGCC) units. For comparison purposes, 500 MW direct coal-fired boilers and 500 MW natural gas-fired combined-cycle units were also considered. The study provides an approximation, for planning purposes, of a reasonable limit of the state's power plant siting capacity, given the plant types and sizes, conditions, and assumptions specified. The study shows that local emission limitations many times preclude certain types of power plants even when they are equipped with Best Available Control Technology (BACT) as required by NSR regulations. This study ...
1980-11-01
Energy Technology Data Exchange (ETDEWEB)
To address the need for integrated models of advanced power generation systems and for improved analysis techniques, the US Department of Energy (DOE), through the Morgantown Energy Technology Center (METC), has supported the development of performance, emissions, and cost models of several advanced power generation systems, including integrated gasification combined cycle (IGCC), externally-fired combined cycle (EFCC) and pressurized fluidized bed combustion (PFBC) concepts. Simultaneously, numerical methods for simulation of uncertainties and optimization of process flowsheets have been implemented in the DOE`s public version of ASPEN. The new process models and computational capabilities have been applied to demonstrate the benefits of quantitative approaches to dealing with uncertainty and for optimizing technologies in the face of uncertainty. This paper focuses on modeling and assessment of the EFCC system concept. The purpose of the ...
1996-10-01
Energy Technology Data Exchange (ETDEWEB)
Within the Annual Conference 2009 of the VGB PowerTech e.V. (Essen, Federal Republic of Germany) from 23rd to 25th May, 2009, in Lyon (France) the following lectures were held: (1) Electricity demand, consequences of the financial and economic crisis - Current overview 2020 for the EU-27 (Hans ten Berge); (2) Status and perspectives of the electricity generation mix in France (Bernard Dupraz); (3) European electricity grid - status and perspective (Dominique Maillard); (4) Technologies and acceptance in the European energy market (Gordon MacKerran); (5) EPR construction in Finland, China, France, (Claude Jaouen); (6) EPR Flamanville 3: A project on the path towards nuclear revival (Jacques Alary); (7) Worldwide nuclear Revival and acceptance (Luc Geraets); (8) An overview on the status of final disposal of radioactive wastes worldwide (Piet Zuidema); (9) Who needs pumped storage plants? PSP are partner to grid stability and renewable energies (Hans-Christoph ...
2009-07-01
International Nuclear Information System (INIS)
Within the Annual Conference 2009 of the VGB PowerTech e.V. (Essen, Federal Republic of Germany) from 23rd to 25th May, 2009, in Lyon (France) the following lectures were held: (1) Electricity demand, consequences of the financial and economic crisis - Current overview 2020 for the EU-27 (Hans ten Berge); (2) Status and perspectives of the electricity generation mix in France (Bernard Dupraz); (3) European electricity grid - status and perspective (Dominique Maillard); (4) Technologies and acceptance in the European energy market (Gordon MacKerran); (5) EPR construction in Finland, China, France, (Claude Jaouen); (6) EPR Flamanville 3: A project on the path towards nuclear revival (Jacques Alary); (7) Worldwide nuclear Revival and acceptance (Luc Geraets); (8) An overview on the status of final disposal of radioactive wastes worldwide (Piet Zuidema); (9) Who needs pumped storage plants? PSP are partner to grid stability and renewable energies (Hans-Christoph ...
2009-09-23
Energy Technology Data Exchange (ETDEWEB)
One of the five projects selected for funding within the Clean Coal Technology Program is a project proposed by the Pennsylvania Electric Company (Penelec) of Johnstown, Pennsylvania. Penelec proposes to enter into a cooperative agreement with DOE to design, construct and operate a 600 ton-per-day, 66-megawatt (MWe), coal-fueled, externally-fired combined cycle (EFCC) electric power generation facility. The EFCC is an emerging technology with promise for operating highefficiency combined gas- and steam-turbine cycles on coal. The central feature of EFCC is its coupling of the gas turbine to an external, atmospheric-pressure, coal combustor via a hightemperature ceramic heat exchanger (CerHx{reg_sign}) developed by Hague International. The EFCC technology is attractive because, unlike competing combined cycles such as Integrated Gasification (IGCC) and Pressurized Fluidized Bed Combustion (PFBC), it eliminates the need for a costly gas cleanup system to protect the ...
1994-06-01
Energy Technology Data Exchange (ETDEWEB)
Coal fired combined cycle power systems will be a sufficient way to increase the efficiency of coal combustion. However, combined cycle power systems require a reliable hot gas cleanup. Especially alkali metals, such as sodium and potassium, can lead to hot corrosion of the gas turbine blading if they condensate as sulphates. The actual work deals with the release and sorption of alkali metals in coal fired combined cycle power systems. The influence of coal composition, temperature and pressure on the release of alkali species in coal combustion was investigated and the relevant release mechanisms identified. Alumosilicate sorbents have been found that reduce the alkali concentration in the hot flue gas of the Circulating Pressurized Fluidized Bed Combustion 2{sup nd} Generation (CPFBC 2{sup nd} Gen.) at 750 C to values sufficient for use in a gas turbine. Accordingly, alumosilicate sorbents working at 1400 C have been found for the Pressurized Pulverized Coal Combustion (PPCC). The ...
2009-07-01
Energy Technology Data Exchange (ETDEWEB)
The operating histories and performance of a large (180 MWsub(e)) central condensing plant and five small (5 MWsub(e)) wellhead backpressure power plants are presented. The thermodynamic performance of the central plant is compared with an estimated possible performance based upon the work of Michaelides. Both types of plant have been shown to be reliable despite some problems due to the contaminants which are associated with geothermal steam.
1986-01-01
Symptoms of the musculoskeletal system and exposure to magnetic fields in an aluminium plant.
UK PubMed Central (United Kingdom)
OBJECTIVE--The study was performed to examine the influence of the exposure to magnetic fields in the potrooms of an electrolysis plant on the occurrence of musculoskeletal symptoms among the employees....Full Text Available
1995-08-01
Systems analysis of the CANDU 3 Reactor
International Nuclear Information System (INIS)
This report presents the results of a systems failure analysis study of the CANDU 3 reactor design; the study was performed for the US Nuclear Regulatory Commission. As part of the study a review of the CANDU 3 design documentation was performed, a plant assessment methodology was developed, representative plant initiating events were identified for detailed analysis, and a plant assessment was performed. The results of the plant assessment included classification of the CANDU 3 event sequences that were analyzed, determination of CANDU 3 systems that are ''significant to safety,'' and identification of key operator actions for the analyzed events.
Energy Technology Data Exchange (ETDEWEB)
The purpose of the chapter is to explain briefly the various considerations that enter into determining the general layout or arrangement of typical hydroelectric powerplants, pumping plants, and pumped-storage plants. Some of the important factors that affect or determine the location, type, and layout of the plant and the selection of the major items of equipment included in the installation are outlined in this chapter. The first consideration in the design of a powerplant, pumping plant, or pumped-storage plant is that it adequately perform its function and be structurally safe. The structure is also designed to give a pleasing architectural appearance.
1985-05-01
Energy Technology Data Exchange (ETDEWEB)
A pipeless batch plant is a batch processing production system using mobile vessels. The plant performances depend on both hardware of equipment and software of operation. So the plant includes many design factors such as number of vessels, stations and AGVS, layout of stations, vessel moving rules, job scheduling and so on. In this paper, the characteristics of pipeless batch plant design are considered to handle the problem by the systems engineering approach. Then, a practical design method known as design-by-analysis is applied to solve such a complex design problem. Based on this concept, a design support system composed of modeling, simulation and evaluation subsystems is developed. This system enables rational decision making through performance evaluation for proposed design of a pipeless batch plant. The usefulness of the system is ...
1997-07-10
Natural convection cooling studies and tests performed for the CREYS MALVILLE plant
International Nuclear Information System (INIS)
For the CREYS MALVILLE plant, sodium natural convection has been considered in connection with certain upset, faulted or beyond design basis situations. For each of these cases, this paper will discuss why natural convection was considered, the main conclusions reached and the natural convection tests which will be performed at plant start-up.
Supplementary quality assurance requirements for subsurface investigations for nuclear power plants
International Nuclear Information System (INIS)
Intended to be used in conjunction with ANSI N45.2 and addresses the quality assurance requirements related to subsurface investigations performed prior to the construction of safety related structures of nuclear power plants.
UK PubMed Central (United Kingdom)
Gas exchange between the plant and the environment is severely hampered when plants are submerged, leading to oxygen and energy deficits. A straightforward way to reduce these shortages of oxygen and...Full Text Available
2005-09-01
Energy Technology Data Exchange (ETDEWEB)
Kawasaki Heavy Industries, Ltd. has developed a gas turbine combined cycle and cogeneration plant computer aided engineering (CAE) system, which creates cycle heat balance automatically on given configurations of gas turbines, heat recovery boilers, steam turbines and auxiliaries. The system can predict the performance of the plant as a function of control set points, loads, process steam requirements and ambient conditions, which enables accurate and fast design of gas turbine combined cycle and cogeneration plants. (author)
1999-04-01
Innovative coke-oven door and cleaning equipment
Energy Technology Data Exchange (ETDEWEB)
Officials of Saturn Machine and Welding Co., describe the company's designs of oven door, door cleaner and jamb cleaner and report performance at US coking plants.
1989-09-01
Energy Technology Data Exchange (ETDEWEB)
This is a presentation on Human Factors in reactor operations. It discusses issues that deal with power plant operations, training and design, operational effectiveness and safety, supporting people to achieve effective and error free performance.
2002-07-01
Gas and coal-fired combined cycle plants
Energy Technology Data Exchange (ETDEWEB)
Fully-fired combined cycle plants utilizing the high temperature gas turbine discharge as gas intake for a coal-fired steam generator were developed in the 1960's. Long-term experience and the excellent reliability statistics of the gas turbines of these plants have proven that the thermodynamic, economical and ecological advantages of combined cycle units over conventional units strongly suggest such plants for fossil-fuel applications. This paper describes the design and operation of these plants. Topics are Gersteinwerk Unit K combined-cycle power plant, plant design concept, design criteria and performance, gas turbines, steam generators, steam turbines, various modes of operation, typical plant start-up, environmental considerations, prototype plants and topping old steam turbine ...
1986-01-01
International Nuclear Information System (INIS)
This standard provides requirements and guidelines for installation, inspection and testing activities that assure the quality of important mechanical parts of a nuclear power plant not covered by the ASME Boiler and Pressure Vessel Code, Section III, during construction. These parts include those mechanical systems and components whose satisfactory performance is required: for the plant to operate reliably; to prevent accidents that could cause undue risk to the health and safety of the public; or to mitigate the consequences of such accidents if they were to occur. The requirements of this standard deal with the protection and control necessary to assure that the requisite quality of those important parts of the plant are preserved from the time items are removed from storage or receiving until they are incorporated into the plant up to but not including fuel loading for PWR ...
Plant maintenance and plant life extension issue, 2006
The focus of the March-April issue is on plant maintenance and plant life extension. Major articles/reports in this issue include: Spent fuel: myths and facts, by Jeffrey S. Merrifield, U.S. Nuclear Regulatory Commission; Critical pipe replacement procedure, by Geoff Gilmore, Climax Portable Machine Tools Inc.; Improving maintenance performance, by Larry Meyer and Joe Giuffre, DC Cook Nuclear Plant, American Electric Power; Equipment deficiency intolerance index, by Douglas F. Helms, Tennessee Valley Authority; Plant profile: I and C modernization at Dukovany, by Josef Rosol, CEZ Dukovany NPP, Czech Republic; and, Report: new plant activities.
2006-03-15
Maintenance viewpoint of a successful reactor program
International Nuclear Information System (INIS)
As the Operating and Support staffs of the FFTF organization have gained experience, the plant reliability and capacity factors have shown a steadily improving trend. The plant capacity factor for Cycle 4 was 99.5%. It is the purpose of this report to describe the evolution of the maintenance organization at the FFTF site from a general support organization to a technically proficient organization playing a major role in planning and performance of plant maintenance evolutions.
1984-06-03
Direct application of West Coast geothermal resources in a wet-corn-milling plant. Final report
Energy Technology Data Exchange (ETDEWEB)
The engineering and economic feasibility of using the geothermal resources in East Mesa, California, in a new corn processing plant is evaluated. Institutional barriers were also identified and evaluated. Several alternative plant designs which used geothermal energy were developed. A capital cost estimate and rate of return type of economic analysis were performed to evaluate each alternative. (MHR)
1981-03-01
Structural material trends in future power plants
Energy Technology Data Exchange (ETDEWEB)
Future power plants will be more fuel efficient, environmentally benign, and economical than current power plants. A high performance power system (HIPPS), based on a coal-fired combined cycle, is currently being developed. The corrosion and temperature-strength properties of currently available metallic materials limit the maximum efficiency of this cycle. Recently, ceramic matrix composites have shown promise in overcoming the design limitations on the future power plants. In particular, the high-temperature, and corrosion and erosion resistant properties of continuous fiber ceramic composites (CFCCs) will allow engineers to design high-temperature heat exchangers, cyclone vortex finder tubes, and other components. Research being performed to evaluate candidate materials for use in future power plants is discussed.
2000-07-01
Power-cycle studies for a geothermal electric plant for MX operating bases
Energy Technology Data Exchange (ETDEWEB)
Binary geothermal plants were investigated for providing electrical power for MX missile bases. A number of pure hydrocarbons and hydrocarbon mixtures were evaluated as working fluids for geothermal resource temperatures of 365, 400, and 450/sup 0/F. Cycle thermodynamic analyses were conducted for pure geothermal plants and for two types of coal-geothermal hybrid plants. Cycle performance results were presented as net geofluid effectiveness (net plant output in watts per geofluid flow in 1 bm/hr) and cooling water makeup effectiveness (net plant output in watts per makeup water flow in 1 bm/hr). A working fluid containing 90% (mass) isobutane/10% hexane was selected, and plant statepoints and energy balances were determined for 20MW(e) geothermal plants at each of the three resource temperatures. Working fluid heaters ...
1981-11-01
Organization and management activities in the nuclear power industry
International Nuclear Information System (INIS)
The purpose of organization and management development activities in the commercial nuclear power industry is to foster high levels of power plant performance and safety through improved human performance. The NRC has been working to develop assessment tools to assay the effects of organizational factors on plant safety. The utility industry has been working on initiatives targeting individual accountability, the improvement of plant performance and the elimination of the items identified through the NRC assessment process. Organization and management activities do not focus on industry organizational charts, but on the personnel processes and dimensions (factors) that affect safety and economic performance. As individual terms these activities are often combined and referred to as organizational factors. As an area of study, organizational ...
1994-04-01
Tehachapi solar thermal system first annual report
Energy Technology Data Exchange (ETDEWEB)
The staff of the Southwest Technology Development Institute (SWTDI), in conjunction with the staff of Industrial Solar Technology (IST), have analyzed the performance, operation, and maintenance of a large solar process heat system in use at the 5,000 inmate California Correctional Institution (CCI) in Tehachapi, CA. This report summarizes the key design features of the solar plant, its construction and maintenance histories through the end of 1991, and the performance data collected at the plant by a dedicated on-site data acquisition system (DAS).
1993-05-01
Workshop on stems and trunks in plant form and function. Final report
Energy Technology Data Exchange (ETDEWEB)
This document is the final report on the workshop on stems and trunks in plant form and function relating to DOE grant DE-FG06-93ER20128 which took place at Oregon State University in February 1994. The resulting book is organized into four sections and a synthesis: roles of stem architecture in plant performance, roles of stems in transport and storage of water, roles of live stem cells in plant performance, and the roles of stems in preventing or reacting to response to plant injury. The synthesis stemmed from debated and discussion by the authors and a few dozen other workshop participants. The authors cover many stem functions, although the list is not exhaustive, and the focus is on terrestrial woody tree stems, primarily of temperate and boreal zones. More research on trunks, branches and twigs is important for a baseline understanding of ...
1995-03-01
Energy Technology Data Exchange (ETDEWEB)
In this study, sensitivity analysis of 100 MWth chemical looping combustion combined cycle (CLC-CC) plant based on fuel cost were performed. By performance analysis, net efficiency of natural gas/syngas fueled CLC-CC plant was 53-54%, corresponding to previous research. We used Chemical Engineering Plant Cost Index and Guthrie method to evaluate plant cost. For syngas fueled CLC-CC plant, the plant cost was higher since lower heating value (LHV) of syngas was lower than that of natural gas and cost of electricity (COE) was also higher since the cost of syngas was higher than that of natural gas. By sensitivity analysis, it was shown that the cost of syngas should be less than 5.3 $/GJ in order to make COE lower than 5.8 c/kWh which was COE of natural gas CLC-CC plant. 15 refs., 2 figs., 5 tabs.
2009-07-01
Coal preparation plant condition-based maintenance
Energy Technology Data Exchange (ETDEWEB)
This report briefly describes the background to colliery engineering maintenance, past experience in machine condition monitoring within coal preparation and the introduction of condition-based maintenance. A role model scheme has been developed for the introduction of condition-based maintenance into coal preparation plants. The report describes the instrumentation and monitoring methods suitable for application to most mineral processing plants, the use of specialist companies to monitor, gather, process and analyse the information and the actions taken by the colliery. Examples of the benefits of operating such a scheme are given in terms of safety, performance and finance. Other problematical aspects of coal processing are examined which have a direct effect on plant condition and availability.
1998-12-31
Continuous emission monitoring and quality assurance requirements for new power plants
International Nuclear Information System (INIS)
Electric utility plants, for which construction commenced after September 18, 1978, must install and operate continuous emission monitoring (CEM) systems to demonstrate compliance with SO_2 and NO_x emission standards. Furthermore, effective December 4, 1987, each plant must develop and implement a CEM quality assurance (QA) program. This paper reviews the CEM and QA requirements set forth by new source performance standards (NSPS) promulgated by the Environmental Protection Agency. The paper summarizes operating characteristics of the 32 power plants currently subject to NSPS and describes the types of CEM systems used by these plants. Also, to the extent available, the paper presents the results of initial (i.e., first quarter 1988) QA activities (e.g., audits and calibration drift assessments) conducted by these plants.
1988-09-25
Vascular plants of the Hanford Site
Energy Technology Data Exchange (ETDEWEB)
An updated listing of the vascular plants of the Hanford Site is provided, along with discussions of how humans may interact with local plants and have influenced the regional flora. Based on examinations of herbarium collections at the Westinghouse Hanford Company, Pacific Northwest Laboratory, Washington State University, and Brigham Young University, 590 vascular plant species have been identified on or near the Hanford Site. This is more than twice the number of species on previously published lists of Hanford Site vascular plants. A review of the plant species that are currently listed as endangered, threatened, sensitive, or otherwise of concern to the Washington State Natural Heritage Program and the Federal Fish and Wildlife Service is included. Color photographs of selected species are included to aid identification. Lists are provided of the Hanford Site ...
1992-07-01
The Daya Bay nuclear power plant performance. An example of international cooperation
International Nuclear Information System (INIS)
Technology transfer is an integral part of Framatome's general approach to its Chinese partners for the Daya Bay, Ling Ao, and Qinshan phase 2 nuclear power plant projects. It has been the subject of major operations covering all activities relevant to project management, design and engineering, manufacturing, and maintenance know-how. This presentation is more particularly devoted to nuclear island maintenance knowledge, which has been extensively transferred by Framatome to the Daya Bay plant owner over a period of four years, through a program including the constitution of mixed Franco-Chinese teams to handle plant maintenance, shadow training of Chinese specialists in the maintenance work performed by Framatome or its subcontractors in France, and theoretical training sessions on equipment mockups in China and France. (author)
1998-10-25
British Library Electronic Table of Contents (United Kingdom)
The ability to cope with plant defense chemicals differs between specialist and generalist species. In this study, we examined the effects of the concentration of the two main iridoid glycosides (IGs) in Plantago lanceolata, aucubin and catalpol, on the performance of a specialist and two generalist herbivores and their respective endoparasitoids. Development of the specialist herbivore Melitaea cinxia was unaffected by the total leaf IG concentration in its host plant. By contrast, the generalist herbivores Spodoptera exigua and Chrysodeixis chalcites showed delayed larval and pupal development on plant genotypes with high leaf IG concentrations, respectively. This result is in line with the idea that specialist herbivores are better adapted to allelochemicals in host plants on which they...
2011-01-01
Carbon dioxide absorption mechanisms of sodium added to calcium oxide at high temperatures
Energy Technology Data Exchange (ETDEWEB)
To apply the CO{sub 2} absorber at about 1000{sup o}C for integrated coal gasification combined cycle (IGCC) furnace, the reactions of calcium oxide and CO{sub 2} at high temperatures was examined. Calcium carbonate reacts with sodium hydrogen carbonate below 200{sup o}C and forms sodium-calcium complex carbonate. The sodium-calcium complex carbonate melts at 813{sup o}C, and the carbon dioxide absorption and discharge reversible reactions of calcium-oxide takes place via liquid at around 1000{sup o}C. Sintering of calcium oxide at high temperature has been successfully avoided by the addition of sodium.
2004-07-01
Performance of high-temperature central receiver systems
Energy Technology Data Exchange (ETDEWEB)
The development of central receiver technology for the production of electricity is reasonably well established. One possible direction for future research and development efforts funded by the Department of Energy is high-temperature, high-performance systems. In this paper, the performance of central receiver systems is investigated for a range of heliostat sizes, field configurations, plant sizes, and receiver temperatures. The maximum plant efficiency achievable in a central receiver system that uses simple cavity geometry is shown for a range of receiver temperatures. The impact of changes in heliostat size, field packing density, and canting and focusing strategies on system efficiency are investigated over a range of plant sizes. The results of the study underscore the importance of accommodating high absorber plane fluxes in order to efficiently produce working temperatures ...
1984-07-01
Incorporation of organizational failures in PSA
International Nuclear Information System (INIS)
A large portion of the work performed at nuclear power plants follows standardized flow paths. For example, although components on which the maintenance crew works differ from one assignment to the next, all assignments basically follow the same process: requesting, reviewing, planning, scheduling, executing, testing, and documenting the work. In general, the term open-quotes work processclose quotes is used to refer to a standardized sequence of tasks designed within the operational environment of an organization to achieve a specific goal. The predictable nature of work processes suggests that a systematic analysis can be conducted to identify the desirable design of the process and to develop performance measures with respect to the strengths and weaknesses in the process. Furthermore, because of the close relationship of the work process to plant performance and ...
1993-06-20
Seismic qualification method of equipment for nuclear power plant
Energy Technology Data Exchange (ETDEWEB)
Safety related equipment installed in Korean Nuclear Power Plants are required to perform a safety function during and after a seismic event. To accomplish this safety function, they must be seismically qualified in accordance with the intent and requirements of the USNRC Reg. Guide 1.100 Rev. 02 and IEEE Std. 344-1987. This paper defines and summarizes acceptable criteria and procedures, based on the Korean experience, for seismic qualification of purchased equipment to be installed in a nuclear power plant. As such the paper is intended to be a concise reference by equipment designers, architectural engineering company and plant owners in uniform implementation of commitments to nuclear regulatory agencies such as the USNRC or Korea Institute of Nuclear Safety (KINS) relating to adequacy of seismic Category 1 equipment. Thus, the paper provides the methodologies which can be used for qualifying ...
1995-12-31
Estimation of essential and trace elements in some medicinal plants by PIXE and PIGE techniques
Energy Technology Data Exchange (ETDEWEB)
Proton induced X-ray emission (PIXE) and proton induced {gamma}-ray emission (PIGE) techniques are employed for the determination of essential and trace elements in some commonly used medicinal plants of north east India. Light elements such as Na, Mg, Al and P are determined by PIGE while medium Z elements such as K, Ca, Mn, Fe, Cu, Zn, Rb and Sr are determined by PIXE. Analysis is performed on pellets (thick targets) prepared using powders of the specimens which, in turn, are obtained following a series of processing steps. Plant based biological certified reference materials (CRMs) served as standards for quantification. These elements are found to be present in varying concentrations in the studied plants, with the contents of Mn and Zn being notably large in certain specimens. Medicinal properties possessed by these plants have been correlated with their elemental distribution.
2008-04-15
Benefit analysis and evaluation of pumped-storage plant in Taipower system
Energy Technology Data Exchange (ETDEWEB)
The operation of pumped-storage plants (PSP) is based on the daily load variations of power demand. It performs power generation at peak load times during the day, and pumps water up into the reservoir during the off-peak times at night. In the Taipower system in Taiwan, there are two pumped storage plants with ten units. These had a total installed capacity of 2,602 MW or a 12 percent capacity at the end of 1995. The plants were able to reduce system generation costs and improve reliability. A Pumped-Storage Plant Benefit Analysis (PSPBA) program was established using the principle of economic dispatch in 1985. This paper explains the rules of the program, the analysis results of the past 10 years, and a a cost benefit evaluation. It was found that the advantages of PSP are not only in supplying the power for peak load, but also in decreasing the total fuel cost. 5 figs., 4 refs.
1995-12-31
International Nuclear Information System (INIS)
Two inactive tracer techniques for determination of the decontamination factor (DF) of evaporation plants for radioactive waste water are described. One method was used for determination of the DF of an one stage pilot plant. The elements Mg, Cd and Co were employed as tracers. The analyses were performed by atomic absorption spectroscopy. The measurements being fast and simple are especially advantageous with test series in pilot plants. In the second method activation analysis was used for measurement of the tracer to determine the DF of a two stage evaporation plant. Europium is added to the stock solution in a concentration of 70 ppm only. With this method a DF of up to 3 . 10"8 can still be determined. (Auth.).
Energy Technology Data Exchange (ETDEWEB)
A two-year demonstration run of a 500 C/100kgf/cm{sup 2}{center_dot}g high-efficiency waste-to-energy pilot plant has been started from February 1998; this plant represents as the final stage of the NEDO project of development of a high-efficiency waste-to-energy plant. Alloy 625 (SB444) and 310 HCbN tubings were selected for the 3rd and 2nd superheater of the pilot plant, respectively, and ten kinds of conventional and new solid-wall tubings, weld overlayed tubings, composite tubings, and cermet spray coated tubings were tested. By means of 6000-hour field corrosion test in three typical domestic plants, material life and corrosion environment for superheater tubings installed in the pilot plant were evaluated. Also, the effect of alloying elements Cr, Ni, Mo, corrosion rate law, etc. were investigated in detail. Furthermore, the design conception and basic ...
1999-11-01
Distributed-processing radiation management system for nuclear power plants
Energy Technology Data Exchange (ETDEWEB)
The importance of radiation management for nuclear facilities including nuclear power plants has increased as the general public understanding has progressed, and necessary information for management must be processed exactly and quickly. In nuclear power plants, radiation management is performed by each individual operation, and collected information is managed by the system of each operation. The distributed-processing radiation management system has been developed aiming to use a general-purpose LAN and make quick and efficient use of information managed by individual operations. This paper describes the system configuration and functions. (author)
1999-06-01
Awarable complexity: a study on CRT picture design based on plant images by NPP operators
International Nuclear Information System (INIS)
Original pictures installed in the 1st and 2nd generation type central control panels (CCP) and new 'Awarable and Complex' pictures were made on personal computers and evaluated. A total 18 of actual plant operators (M=32.3, SD=10.5 years old) participated in the evaluation. The operators rated the new CRT pictures highly. The response times using the new CRT pictures were shorter than those by the original pictures. Both results suggested that the CRT picture design guidelines based on the operators' plant images were effective for improving their performance. (author)
2000-12-01
Energy Technology Data Exchange (ETDEWEB)
As part of the ICAP (International Code Assessment and Applications Program) agreement between ECN (Netherlands Energy Research Foundation) and USNRC, ECN has performed a number of assessment calculations for the thermohydraulic system analysis code RELAP5/MOD2/36.05. This document describes the assessment of this computer program versus a natural circulation experiment as conducted at the Borssele Nuclear Power Plant. The results of this comparison show that the code RELAP5/MOD2 predicts well the natural circulation behaviour of Nuclear Power Plant Borssele.
1993-07-01
UK PubMed Central (United Kingdom)
Three flocks raised for broiler or roaster performance tests were studied to determine the incidence and sources of salmonellae during the growing period, transport and processing and to relate these...Full Text Available
1982-07-01
Study on the transient piping vibration of power plant. Secondary piping system of Wolsung 1 unit.
In order to maintain a safe operation and availability of generating facilities, qualitative and quantitative assessment of piping vibration was performed vibration sources and damages of piping support was identified on the second piping system of Wolsun...
1996-01-01
Posttest analysis of the FFTF inherent safety tests
Energy Technology Data Exchange (ETDEWEB)
Inherent safety tests were performed during 1986 in the 400-MW (thermal) Fast Flux Test Facility (FFTF) reactor to demonstrate the effectiveness of an inherent shutdown device called the gas expansion module (GEM). The GEM device provided a strong negative reactivity feedback during loss-of-flow conditions by increasing the neutron leakage as a result of an expanding gas bubble. The best-estimate pretest calculations for these tests were performed using the IANUS plant analysis code (Westinghouse Electric Corporation proprietary code) and the MELT/SIEX3 core analysis code. These two codes were also used to perform the required operational safety analyses for the FFTF reactor and plant. Although it was intended to also use the SASSYS systems (core and plant) analysis code, the calibration of the SASSYS code for FFTF core and plant analysis ...
1987-01-01
Posttest analysis of the FFTF inherent safety tests
International Nuclear Information System (INIS)
Inherent safety tests were performed during 1986 in the 400-MW (thermal) Fast Flux Test Facility (FFTF) reactor to demonstrate the effectiveness of an inherent shutdown device called the gas expansion module (GEM). The GEM device provided a strong negative reactivity feedback during loss-of-flow conditions by increasing the neutron leakage as a result of an expanding gas bubble. The best-estimate pretest calculations for these tests were performed using the IANUS plant analysis code (Westinghouse Electric Corporation proprietary code) and the MELT/SIEX3 core analysis code. These two codes were also used to perform the required operational safety analyses for the FFTF reactor and plant. Although it was intended to also use the SASSYS systems (core and plant) analysis code, the calibration of the SASSYS code for FFTF core and plant analysis ...
1987-06-07
Marine Ecosystem Analysis for Wolsung Nuclear Power Plant.
Environmental surveys to provide base-line data for assessing the potential impact of the operation of Wolseong NPP on marine ecosystems were performed at 3-month intervals in 1981. Physico-chemical properties of seawater and gross beta activities in seaw...
1982-01-01
Flue gas desulfurization: scrubber types and selection criteria
Economic and performance criteria that should be used in the selection of a scrubber system are presented. Selection should be based on the type of emissions put out by a plant and the removal efficiency required by pollution control standards. Costs and efficiencies for 10 different scrubber systems are reported. (10 diagrams)
1980-05-01
Experience of static electrification in power transformer
Energy Technology Data Exchange (ETDEWEB)
This document is a discussion of a static electrification event in each of the 1050 MVA units installed at the Koeburg Nuclear Power Plant in South Africa. Results of a tear-down inspection performed after the event are given, as is an analysis of the event. A number of photographs are included.
1995-05-01
COMPUTER ECONOMICS OF PHYSICAL COAL CLEANING AND FLUE GAS DESULFURIZATION. FINAL REPORT
The report describes a computer model developed by TVA to simulate the performance and determine the economics of coal cleaning, or coal cleaning combined with flue gas desulfurization (FGD), for power plant emission control processes over a wide range of user-specified condition...
The application of MOX fuel in light water nuclear power plant
International Nuclear Information System (INIS)
MOX fuel has been one of the mature nuclear fuels which can be used in light water nuclear power plant now. The development status in this domain in foreign countries, the major influence of MOX fuel on reactor performance and the countermeasures are introduced in this paper. The application of MOX fuel in China's PWR is discussed in the end. (authors)
2008-12-01
Teleobservation in hostile environment
International Nuclear Information System (INIS)
In order to meet the needs of remote servicing performed in nuclear power plants, in fuel reprocessing plants and in atomic research centers three companies: - STMI, subsidiary of CEA, EDF and SGN, specialized in decontamination and dismantling, - La Calhene, subsidiary of CEA and SGN, specialized in robotics, - Inspectronic, manufacturer of closed circuit television cameras, have combined to create the Visionic Society, the main objectives of which are observation by television and inspections in radioactive environment.
Radioactive source management in Daya Bay NPP
International Nuclear Information System (INIS)
'Small radioactive source results in big accident' have occurred repeatedly in China and worldwide alike. Radioactive source management is one of the key activities for a nuclear power plant to maintain its good safety record and image to the public. From aspects of establishing the management system, centralized storage, periodic accounting, performing whole process control to the source usage and experience feedback etc., the author reports the practice and experience of radioactive source management in Daya Bay Nuclear Power Plant
1999-11-01
PFB coal fired combined cycle development program. System analyses and trade-offs (Task 1. 3)
Energy Technology Data Exchange (ETDEWEB)
The systems analyses and optimization studies performed in connection with a program to design and evaluate a commercial 663 MWe coal-fired combined cycle power plant using pressurized fluidized bed combustion and advanced technology in the hot gas cleanup system and gas turbines are presented. Details on the plant control system are included. (LCL)
1981-02-01
Management considerations of the large primary-to-secondary leakage accidents
Energy Technology Data Exchange (ETDEWEB)
The management procedure of a large PRISE (Primary-to-Secondary) leakage accident at Loviisa nuclear power plant taking into account the plant modifications which are expected to be realized during 1995-96 is described. The management procedure has been validated by performing thermal hydraulic analyses with the computer code RELAP5/MOD3 and the results from these analyses are also shortly discussed. (4 refs., 6 figs., 1 tab.).
1993-12-31
Instrumentation and control improvements at Experimental Breeder Reactor II
Energy Technology Data Exchange (ETDEWEB)
The purpose of this paper is to describe instrumentation and control (I C) system improvements at Experimental Breeder Reactor 11 (EBR-11). The improvements are focused on three objectives; to keep the reactor and balance of plant (BOP) I C systems at a high level of reliability, to provide diagnostic systems that can provide accurate information needed for analysis of fuel performance, and to provide systems that will be prototypic of I C systems of the next generation of liquid metal reactor (LMR) plants.
1993-01-01
Instrumentation and control improvements at Experimental Breeder Reactor II
Energy Technology Data Exchange (ETDEWEB)
The purpose of this paper is to describe instrumentation and control (I&C) system improvements at Experimental Breeder Reactor 11 (EBR-11). The improvements are focused on three objectives; to keep the reactor and balance of plant (BOP) I&C systems at a high level of reliability, to provide diagnostic systems that can provide accurate information needed for analysis of fuel performance, and to provide systems that will be prototypic of I&C systems of the next generation of liquid metal reactor (LMR) plants.
1993-03-01
Hot Particles Research for Nuclear Power Plant in Wolsung
Energy Technology Data Exchange (ETDEWEB)
The evaluation of the hazard posed to the skin by very small radioactive sources (diameter < 1mm) has become popularly known as the 'hot particle' problem in European and American nuclear reactor facilities. In this study, research to detect hot particle was performed in Wolsung Nuclear power plant (NPP) in Korea.
2007-10-15
Hot Particles Research for Nuclear Power Plant in Wolsung
International Nuclear Information System (INIS)
The evaluation of the hazard posed to the skin by very small radioactive sources (diameter < 1mm) has become popularly known as the 'hot particle' problem in European and American nuclear reactor facilities. In this study, research to detect hot particle was performed in Wolsung Nuclear power plant (NPP) in Korea.
2007-10-01
Energy Technology Data Exchange (ETDEWEB)
The results of the development work to improve the horizontal steam generator modelling using the CATHARE code as well as the results of the steady-state and the steam-line break calculations are presented. Also the results of the steady-state calculations are compared to the measurements performed in operating VVER power plants. (9 refs., 6 figs., 2 tabs.).
1993-12-31
International Nuclear Information System (INIS)
The results of the development work to improve the horizontal steam generator modelling using the CATHARE code as well as the results of the steady-state and the steam-line break calculations are presented. Also the results of the steady-state calculations are compared to the measurements performed in operating VVER power plants. (9 refs., 6 figs., 2 tabs.).
1992-09-29
Energy Technology Data Exchange (ETDEWEB)
The Heat Cycle Research Program, which is conducted for the Department of Energy, has as its objective the development of the technology for effecting the improved utilization of moderate temperature geothermal resources. The current testing involves the investigation of the performance of binary power cycles utilizing mixtures of non-adjacent hydrocarbons as the working fluids, with supercritical vaporization and in-tube condensation. The utilization of these concepts will improve the net geofluid effectiveness (net plant output per unit mass of geofluid) about 20% over that of a conventional binary power plant. The major prerequisite for this improvement is the achievement of integral, countercurrent condensation. Results are presented for testing of the performance of the condenser at different tube inclinations. The performance in the vertical orientation is better than in ...
1989-01-01
International Nuclear Information System (INIS)
On March 31, 1995, the US Department of Energy filed a draft application for certification of compliance with the US Environmental Protection Agency (USEPA) to show the Waste Isolation Pilot Plant's compliance with the USEPA's environmental standards, making the application the first of its kind. Demonstration of compliance is by performance assessment. This paper is an early review of the performance assessment in the draft application, by the Environmental Evaluation Group, an oversight group. The performance assessment in the draft application is incomplete. Not all relevant scenarios have been analyzed. The calculation of potential consequences often does not use experimental data but rather estimates by workers developing additional data. The final compliance application, scheduled for October 1996 needs to consider additional scenarios, and be fully based on experimental data.
Tidd experience prepares hot gas cleaning technology for commercialization
Energy Technology Data Exchange (ETDEWEB)
Pressurized fluidized bed combustion (PFBC) is an emerging coal-fired, combined-cycle power generation technology nearing commercial status through several operating and planned demonstration plants throughout the world. Current-generation PFBC plants use ``ruggedized`` gas turbines that can tolerate dust loading common with conventional cyclone gas cleaning. The next generation of PFBC will apply advanced hot gas cleaning systems that will reuse the dust loading to low levels acceptable to high performance, industrial gas turbines. These advances should result in performance and cost advantages. This article examines the demonstration of PFBC technology at Tidd power station.
1995-09-01
Shell coal gasification plant (SCGP-1) environmental performance results
Energy Technology Data Exchange (ETDEWEB)
Environmental studies in slip-stream process development units at SCGP-1, Shell's advanced coal gasification demonstration plant, located near Houston, Texas, have demonstrated that the gas and water effluents from the Shell Coal Gasification Process (SCGP) are environmentally benign on a broad slate of coals. This report presents the results of those environmental studies. It contains two major subjects, which describe, respectively, the experiments on gas treating and the experiments on water treating. Gas treatment focused on the performance of aqueous methyldiethanolamine (MDEA) and sulfinol-M. 8 refs., 24 figs., 13 tabs.
1991-07-01
Radiological hazards in uranium mines and a yellow-cake plant in Turkey
Energy Technology Data Exchange (ETDEWEB)
Radiological hazard in uranium mining and milling operations are primarily due to exposure to external beta and gamma radiation as well as to airborne radionuclides which consist of radon and its short-lived daughter products. In May 1981 a radiological survey programme was performed in order to make a general assessment of the radiation hazards associated with the uranium mines and the Uranium Pilot Plant operated by the M.T.A. Institute in the Koprubasi district of the Manisa province. In this paper a preliminary radiological risk evaluation attempt is presented based on the radiation and radioactivity measurements performed in this district in May 1981.
1984-06-01
Corrosion studies at the Wilsonville, Alabama, coal liquefaction facility during 1983
During 1983, Oak Ridge National Laboratory continued a study of materials performance at the Wilsonville, Alabama, Advanced Coal Liquefaction Research and Development Facility. Materials performance was evaluated by exposure and analysis of corrosion coupons and U-bend specimens, chemical analysis of related process streams, and ultrasonic determination of the thickness of walls of various components. The results of these studies are useful to current plant operators and to designers of future large-scale plants. 18 references, 4 figures, 12 tables.
1984-10-01
Acceptance test of full scope simulator of Daya Bay NPP
International Nuclear Information System (INIS)
The author describes the purpose, classification and main process of acceptance test of full scope simulator of Daya Bay Nuclear Power Plant, including the correction of non-conformance items which are discovered during the performance of acceptance tests. The results of the acceptance tests show that the model accepted by the full scope simulator of Daya Bay Nuclear Power Plant is fully able to cope with the simulation of normal transients and incidental transients and the performance of the simulator indeed compiled with the technical specifications which are defined n the relevant contracts.
Second international symposium on nuclear power plant life management. Book of extended synopses
International Nuclear Information System (INIS)
The world's fleet of nuclear power plants is, on average, more than 20 years old. Even though the design life of a nuclear power plant is typically 30-40 years, it is quite feasible that many plants will be able to operate in excess of their design lives, provided that nuclear power plant engineers demonstrate by analysis, trending, equipment and system upgrades, increased vigilance, testing and ageing management that the plant will operate safely. In the operation of nuclear power plants, safety should be always the prime consideration. Plant operators and regulators must always ensure that plant safety is maintained, and where possible enhanced, during a plant's operating lifetime. Nuclear power plant life management (PLiM) has gained increased attention over the past decade, ...
2007-10-15
The experience of obsolete item identification and solution in CANDU NPPs
International Nuclear Information System (INIS)
Design and procurement of equipment for nuclear power plant took place in late 1970's. A large number of originally installed equipment is obsolete. The manufacturer's do not support their products or have discontinued their production due to technological evolutions or lack of product demand. Lack of spares affects the performance of obsolete equipment and has a negative impact on plant safety and plant production. A proactive approach to address obsolescence is necessary to ensure critical spares are always available when needed. This is an ongoing effort and requires a program to be in place to resolve immediate and longterm issues. A cross-functional team with adequate external exposure is needed to administer the obsolescence program. CANDU utilities and CANDU Owners Group(COG) has taken initiatives to identify lack of equipment spares in the members' plant. The equipment ...
2010-10-01
Energy Technology Data Exchange (ETDEWEB)
This paper describes EPRI`s computer based Performance, Operation and Maintenance Management System (``POMMS``) consisting of four (4) modules (``Modules``). These Modules are used to monitor, evaluate and analyze the cost effective operation of simple cycle and combined cycle gas turbine power plants. Inputs to POMMS relating to plant performance, availability and maintenance are monitored, stored in a data acquisition system and analyzed to determine their impact on performance and cost parameters. POMMS was developed by EPRI, Project Manager Fluor Daniel Power Generation Company and by the subcontractors who, together, engineered the individual POMMS Modules while working on EPRI`s Durability Surveillance of Advanced Gas Turbines Project (``Project``). The following modules are described in this paper and may be applied together or individually: Rotating Blade Temperature ...
1994-12-31
Fingerprint testing of contaminated ventilation extract filter systems at Sizewell B
International Nuclear Information System (INIS)
Sizewell B is Nuclear Electric's latest power station, and the Pressurised Water Reactor (PWR) design on which it is based represents a ''first'' for the UK. One of the integral components of the plant is the heating, ventilation and air-conditioning (HVAC) system, which performs a contamination control and gaseous waste management function for the site. During the commissioning of Sizewell B Power Station the extract systems of the HVAC plant underwent a procedure known as ''fingerprinting''. This entailed the characterisation of the facilities provided to test the filtration plant during its lifetime. The assessment of their adequacy was then used to identify necessary modifications and/or to propose the manner in which future in situ performance testing would be carried out. The paper outlines the basic principles and procedure that was used to ''fingerprint'' test systems during ...
Psychological test performance in foundry workers exposed to low levels of manganese
Energy Technology Data Exchange (ETDEWEB)
A sample of 30 manganese-exposed foundry workers from two Swedish plants were examined with a partly computerized psychological test battery, comprised of 10 performance tests. Performance of the manganese-exposed workers was compared to that of a matched control group of 60 workers. Matching criteria were age, geographical area, type of work, and the results on a test of verbal comprehension. Performance of the exposed workers was inferior to that of the control group on tests of simple reaction time, digit span, and finger tapping. No correlations were found between performance and the present manganese exposure levels or the number of years employed in manganese work. The results seem to indicate that the present exposure standards for manganese, in Sweden 2.5 mg/m3 and in most other countries 5 mg/m3, are not sufficient to protect workers from negative effects on ...
1990-11-01
British Library Electronic Table of Contents (United Kingdom)
Triacontanol (TRIA) has been realized as a potent plant growth promoting substance for a number of agricultural and horticultural crops. Out of a large number of essential oil bearing plants, mint (Mentha arvensis L.) constitutes the most important source of therapeutic agents used in the alternative systems of medicine. The mint plant has marvelous medicinal properties. In view of enhancing growth, yield and quality of this medicinally important plant, a pot experiment was conducted according to simple randomized block design. The experiment was aimed at studying the effect of four concentrations of TRIA (10?0, 10?7, 10?6 and 10?5?M) on the performance of mint with regard to growth and other physiological attributes, crop yield and quality attributes and the yield and contents of active c...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Elemental analysis of some medicinal plants used in the Indian Ayurvedic system was performed by employing instrumental neutron activation analysis (INAA) and atomic absorption spectroscopy (AAS) techniques. The samples were irradiated with thermal neutrons in a nuclear reactor and the induced activity was counted by gamma ray spectrometry using an efficiency calibrated high resolution high purity germanium (HPGe) detector. Most of the medicinal plants were found to be rich in one or more of the elements under study. The variation in elemental concentration in same medicinal plants samples collected in summer, winter and rainy seasons was studied and the biological effects of these elements on human beings are discussed. (orig.)
2009-07-01
Structural analysis and stress evaluation system for steel structures: ADAMS
Energy Technology Data Exchange (ETDEWEB)
In order to perform the structural analysis and stress evaluation for frame structures in the nuclear power plants, ADAMS (AIJ Design Analysis and Modules System) has been developed by the addition of the following functions to the ICES-STRUDL system. 1. Load combination and stress evaluation on the basis of specifications for designing steel structure (issued by the Architecture Institute of Japan). 2. Combination of load and stress evaluation of piping support on the basis of the regulations of Ministry of International Trade and Industry. 3. Addition of other functions than that described above. ADAMS enables structural analysis and stress evaluation exactly and efficiently not only for a large scale structure such as the pipe whip protection structure installed inside of the primary containment vessel for many loading cases but also for a large number of structures such as piping support. This system can be applied not only to nuclear power ...
1980-11-01
British Library Electronic Table of Contents (United Kingdom)
This study was developed as part of the project ?Studies for Environmental and Cultural Sustainability of the Fulni-? Medical System: Office on handling medicinal plants?. The Fulni-? people are located in Pernambuco State, Northeastern Brazil. One of the components of this project was an ethnobotanical diagnosis of the indigenous land, where a phytosociological survey was performed in an area of Caatinga vegetation, located at Ouricuri settlement. Based on these ethnobotanical data, we calculated a conservation priority index aiming to rank species that should receive immediate attention from the Fulni-? people. We identified 44 woody plants, 50% of which have a medicinal use. Among these, six plants were considered highly vulnerable and in need of immediate conservationist attention, in ...
2011-01-01
Performance Assessment of Wolsung Unit 2 Safety Grade Pumps using In-Service Test
Energy Technology Data Exchange (ETDEWEB)
Nuclear power plant has several safety features and each safety feature is based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear power plant to keep operational readiness of pumps and valves by In-Service Test (IST). According to Ministry of Education, Science and Technology (MEST) Bulletin 2008-14, the safety functioned pumps and valves of all nuclear power plants of Korea Hydro and Nuclear Power Co. Ltd.(KHNP) have been tested to verify their performance of safety function. Each safety grade pump has own design requirement and should be tested to identify whether it could meet the requirement. Design requirements and test references of all safety grade pumps of Wolsung Nuclear Power Plant Unit 2 (Wolsung Unit 2) were examined in this study. And the results of the performance test of the pump were also ...
2008-10-15
Performance Assessment of Wolsung Unit 2 Safety Grade Pumps using In-Service Test
International Nuclear Information System (INIS)
Nuclear power plant has several safety features and each safety feature is based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear power plant to keep operational readiness of pumps and valves by In-Service Test (IST). According to Ministry of Education, Science and Technology (MEST) Bulletin 2008-14, the safety functioned pumps and valves of all nuclear power plants of Korea Hydro and Nuclear Power Co. Ltd.(KHNP) have been tested to verify their performance of safety function. Each safety grade pump has own design requirement and should be tested to identify whether it could meet the requirement. Design requirements and test references of all safety grade pumps of Wolsung Nuclear Power Plant Unit 2 (Wolsung Unit 2) were examined in this study. And the results of the performance test of the pump were also ...
2008-10-01
International Nuclear Information System (INIS)
Human resource competence building and continued enhancement of performance is the most vital input for safe and reliable operations of a Nuclear Power Plant. Integrated planning leading to the decision of timely selection of optimum number of fresh people and deployment of experienced manpower with desired lead time is inevitable to achieve the above objective. For safe and reliable plant operation human performance analysis followed by suggestive measures to improve the same is needed. Corrective or strengthening input may be in terms of training, work environment, motivations, organizational culture and climate, leadership and prevailing environmental force and bio-rhythm of individuals with critical days are to be worked out The adequacy in training and development not only gives safe and reliable plant operations but results in greater employee satisfaction and self esteem as ...
2006-11-13
PFB coal fired combined cycle development program. Final report
Energy Technology Data Exchange (ETDEWEB)
A final report is presented on the design, environmental characteristics, performance and maintainability, and economic analysis of a commercial 663 MWe coal-fired combined cycle power plant using pressurized fluidized bed combustion, and advanced technology in the hot gas cleanup system and gas turbines. Experimental data on the performance of each of the major components are included. (LCL)
1981-03-01
Elemental investigation of Syrian medicinal plants using PIXE analysis
Energy Technology Data Exchange (ETDEWEB)
Particle induced X-ray emission (PIXE) technique has been employed to perform elemental analysis of K, Ca, Mn, Fe, Cu, Zn, Br and Sr for Syrian medicinal plants used traditionally to enhance the body immunity. Plant samples were prepared in a simple dried base. The results were verified by comparing with those obtained from both IAEA-359 and IAEA-V10 reference materials. Relative standard deviations are mostly within {+-}5-10% suggest good precision. A correlation between the elemental content in each medicinal plant with its traditional remedial usage has been proposed. Both K and Ca are found to be the major elements in the samples. Fe, Mn and Zn have been detected in good levels in most of these plants clarifying their possible contribution to keep the body immune system in good condition. The contribution of the elements in these plants to the dietary ...
2010-09-15
Energy Technology Data Exchange (ETDEWEB)
A cost study is described which compared the economics of four dry/wet cooling systems to use at the existing Raft River Geothermal Plant. The results apply only at this site and should not be generalized without due consideration of the complete geothermal cycle. These systems are: the Binary Cooling Tower, evaporative condenser, Combin-aire, and a metal fin-tube dry cooling tower with deluge augmentation. The systems were evaluated using cooled, treated geothermal fluid instead of ground or surface water in the cooling loops. All comparisons were performed on the basis of a common plant site - the Raft River 5 MWe geothermal plant in Idaho. The Binary Cooling Tower and the Combin-aire cooling system were designed assuming the use of the isobutane/water surface condenser currently installed at the Raft River Plant. The other two systems had the isobutane ducted to the evaporative ...
1982-07-01
Energy Technology Data Exchange (ETDEWEB)
Before disposing of transuranic radioactive wastes in the Waste Isolation Pilot Plant (WIPP), the United States Department of Energy (DOE) must evaluate compliance with applicable long-term regulations of the United States Environmental Protection Agency (EPA). Sandia National Laboratories is conducting iterative performance assessments of the WIPP for the DOE to provide interim guidance while preparing for final compliance evaluations. This volume contains an overview of WIPP performance assessment and a preliminary comparison with the long-term requirements of the Environmental Radiation Protection Standards for Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive Wastes (40 CFR 191, Subpart B).
1992-12-01
Energy Technology Data Exchange (ETDEWEB)
The successful development of coal-fired combined cycle power generation systems require that all component parts are manufactured from appropriate materials and that these materials give predictable in-service performance. High temperature corrosion resulting from coal-derived particulates, deposition and gaseous species, is potentially life limiting for many components in these systems. Realistic laboratory test methods are outlined for gasifier and gas turbine environments and these have been combined with a materials assessment method based on accurate dimensional metrology. Such tests have allowed the production of models of materials performance as well as accurate comparisons between laboratory and plant derived data. These initial models predict the performance of materials well in the gas turbine environment, but tend to under-predict the damage observed in real gasifier environments. The ...
1997-12-31
Performance Testing Methodology for Safety-Critical Programmable Logic Controller
International Nuclear Information System (INIS)
The Programmable Logic Controller (PLC) for use in Nuclear Power Plant safety-related applications is being developed and tested first time in Korea. This safety-related PLC is being developed with requirements of regulatory guideline and industry standards for safety system. To test that the quality of the developed PLC is sufficient to be used in safety critical system, document review and various product testings were performed over the development documents for S/W, H/W, and V/V. This paper provides the performance testing methodology and its effectiveness for PLC platform conducted by KOPEC
2009-05-01
Safety performance indicators. Topical issues paper no. 5
International Nuclear Information System (INIS)
Since its creation the nuclear industry has been struggling with the question of how safe is safe enough. Safety is a common goal to all involved in the design, operation and regulation of a nuclear installation. As a concept safety is not easy to define. However, there is a general understanding of what attributes a nuclear power plant should have in order to operate safely. The challenge lies in measuring the attributes. The new competitive open electricity market, in many countries throughout the world, is increasing the economic pressure on operators to lower operating costs without jeopardizing safety. Challenges are occurring at a rate that is unprecedented in the nuclear industry: competitiveness; downsizing; ageing; policy changes; reorganization; restructuring; mergers; globalization; and takeovers demand increasing attention to the management of safety. There are various means to measure safety performance, some of which are more ...
2001-09-03
Korean experience in CANDU-PHWR operation
Among KEPCO's 9 nuclear power units, Korea Nuclear Unit No. 3, the Wolsung Nuclear Power Plant is the only CANDU-PHWR Unit, while the rest of 8 others are PWR units. The unit was designed by Atomic Energy of Canada, Ltd. of Canada, who also performed overall project management for the plant construction under the provisions and arrangement of the relevant contracts. The gross electrical output of the plant is 678.7 MWe and thermal output of the reactor is 2061 MWth. While these figures lead to lower plant efficiency than LWR counterparts, unit energy cost for fuel is more favorable than LWRs because natural uranium is utilized for the fuel bundles, some of which are already being fabricated domestically. Annual capacity factors for 1983 and 1984 could have been improved, if two major planned outages for the modification works on steam generator internals and one major ...
1988-01-01
Engineering Development of Coal-Fired High-Performance Power Systems
Energy Technology Data Exchange (ETDEWEB)
A High Performance Power System (HIPPS) is being developed. This system is a coal-fired, combined cycle plant with indirect heating of gas turbine air. Foster Wheeler Development Corporation and a team consisting of Foster Wheeler Energy Corporation, Bechtel Corporation, University of Tennessee Space Institute and Westinghouse Electric Corporation are developing this system. In Phase 1 of the project, a conceptual design of a commercial plant was developed. Technical and economic analyses indicated that the plant would meet the goals of the project which include a 47 percent efficiency (HHV) and a 10 percent lower cost of electricity than an equivalent size PC plant. The concept uses a pyrolysis process to convert coal into fuel gas and char. The char is fired in a High Temperature Advanced Furnace (HITAF). The HITAF is a pulverized fuel-fired boiler/air heater where steam is ...
2000-12-31
Energy Technology Data Exchange (ETDEWEB)
The performance of binary geothermal power plants can be improved through the proper choice of a working fluid, and optimization of component designs and operating conditions. This paper reviews the investigations at the Idaho National Engineering Laboratory (INEL) which are examining binary cycle performance improvements: for moderate temperature (350 to 400 F) resources with emphasis on how the improvements may be integrated into design of binary cycles. These investigations are examining performance improvements resulting from the supercritical vaporization of mixed hydrocarbon working fluids and achieving countercurrent integral condensation with these fluids, as well as the modification of the turbine inlet state points to achieve supersaturated turbine vapor expansions. For resources where the brine outlet temperature is restricted, the use of turbine exhaust recuperators is examined. The baseline ...
1989-03-21
International Nuclear Information System (INIS)
The Belgian Tihange 2 nuclear power plant went into commercial operation in 1983 producing a thermal power of 2785 MW. Since the commissioning of the plant the steam generators U-tubes have been affected by primary stress corrosion cracking. In order to avoid further degradation of the performance and an increase in repair costs, Electrabel, the owner of the plant, decided in 1997 to replace the 3 steam generators. This decision was supported by the feasibility study performed by Tractebel Energy Engineering which demonstrated that an increase of 10% of the initial power together with a fuel cycle length of 18 months was achieved. Tractebel Energy Engineering was entrusted by Electrabel as the owner's engineer to manage the project. This paper presents the role of Tractebel Energy Engineering in this project and the safety analysis program necessary to justify the new operation ...
2002-08-11
Final phase testing and evaluation of the 500 kW direct contact pilot plant at East Mesa
Energy Technology Data Exchange (ETDEWEB)
The testing performed during the last phase of the geothermal direct contact heat exchanger program utilizing the 500 kW pilot plant provided more insight into the capabilities and limits of the direct contact approach and showed that more work needs to be done to understand the inner workings of a large direct contact heat exchanger if they are to be modeled analytically. Testing of the column demonstrated that the performance was excellent and that the sizing criteria is conservative. The system operated smoothly and was readily controlled over a wide range of operating conditions. Performance evaluation showed pinch differentials of 4/sup 0/F or less and better than predicted heat transfer capability. Testing during this final phase was directed towards establishing the limits of the column to transfer heat. The working column height was shortened progressively to approximately 16 feet from a design ...
1983-12-01
The preliminary success of ALARA implementation in Daya Bay NPP
International Nuclear Information System (INIS)
Based on the practical condition of the plant and in reference to advanced management experiences worldwide, Daya Bay Nuclear Power Plant has established its own peculiar management system for radiation protection management and ALARA implementation. The characteristics of the system are: radiation protection training to all workers, active involvement of all managers and staffs, and whole process safety control to maintenance activities. The management philosophy of 'workers are responsible for their own radiation safety' is adopted in the plant. A strict, formalized and systematic whole staff radiation protection training, evaluation, authorization and periodically refreshing mechanism had been established and executed in the plant. In the organizational point of view, the responsibilities of line managers were specified in plant procedures, ALARA coordination organization on ...
2000-05-01
Energy Technology Data Exchange (ETDEWEB)
This paper reports the estimates concerning the atmospheric carbon dioxide absorption and storage by living plants all over the world. It is necessary to decrease atmospheric carbon dioxide concentrations for avoiding global warming. As living plants absorb carbon dioxide by photosynthesis and accumulate carbon in their bodies, they can play an important role to remove atmospheric carbon dioxide. Literatures describing distribution areas, biomass values and net primary productivity (NPP) of forests, marine plants and microorganisms were collected. Examining those data, the biomass and NPP of forests, marine plants and microorganisms can be summarized as follows: (1) Forest biomass and their NPP of the world. The world's forest area is recently estimated as 4 billion hectares, and their biomass is about 400 billion tons of carbon which is equal to 2/3 of the total atmospheric carbon. The NPP of ...
1992-01-01
Iron Aluminide Hot Gas Filters
Energy Technology Data Exchange (ETDEWEB)
Currently, high temperature filter systems are in the demonstration phase with the first commercial scale hot filter systems being installed on integrated gasification combined cycle (IGCC) and pressurized fluid bed combustion cycle (PBFC) systems (70 MW). They are dependent on the development of durable and economic high temperature filter systems. These filters are mostly ceramic tubes or candles. Ceramic filter durability has not been high. Failure is usually attributed to mechanical or thermal shock: they can also undergo significant changes due to service conditions. The overall objective of this project is to commercialize weldable, crack resistant filters which will provide several years service in advanced power processes. The specific objectives of this project are to develop corrosion resistant alloys and manufacturing processes to make Iron Aluminide filter media, and to use a ``short term`` exposure apparatus supported by other tests to identify the ...
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
An overall view of the 1982 plant operating performance is presented. All periods of ON-FEED operation, UNSCHEDULED SHUTDOWNS, and SCHEDULED SHUTDOWNS are accounted for and tabulated. Causes of UNSCHEDULED SHUTDOWNS are identified and discussed. Plant solutions aimed at reducing the effect of similar future shutdowns or preventing recurrence of such shutdowns are explained. Details of repeated, major maintenance problems with various pieces of equipment are presented. Discussion of each problem and solutions found during 1982 are given, where applicable.
1983-12-01
Validation studies of thermal-hydraulic code for safety analysis of nuclear power plants
Energy Technology Data Exchange (ETDEWEB)
The thesis gives an overview of the validation process for thermal-hydraulic system codes and it presents in more detail the assessment and validation of the French code CATHARE for VVER calculations. Three assessment cases are presented: loop seal clearing, core reflooding and flow in a horizontal steam generator. The experience gained during these assessment and validation calculations has been used to analyze the behavior of the horizontal steam generator and the natural circulation in the geometry of the Loviisa nuclear power plant. Large part of the work has been performed in cooperation with the CATHARE-team in Grenoble, France. (41 refs., 11 figs., 8 tabs.).
1995-12-31
United States Gypsum Plant Solar Retrofit Program
Energy Technology Data Exchange (ETDEWEB)
A conceptual design of a solar retrofit to US Gypsum's plant at Sweetwater, Texas, has been developed which provides heated air to a large gypsum board drying kiln that is currently under construction. The solar heated air displaces natural gas normally used for the process heat. The solar retrofit is composed of a tower focus collector with a cavity receiver which uses air as the heat transfer fluid. An executive summary of the conceptual design, system performance, economics, and development plan is presented. (WHK)
1980-07-01
The analysis of temperature distribution for surveillance Capsule in reactor vessel of YGN unit 1
International Nuclear Information System (INIS)
Generally, Hardening and irradiated brominating phenomena are occurred in the reactor vessel under operation conditions by atomic cavities and creation of impurity atoms which are led by high fast neutron flux. To assure the mechanical integrity of pressure vessel until the end of power plant life after monitoring the sample specimens on the vessel inside, a series of tests is performed over the retrieved surveillance capsule to examine the changes according to the plant operation in accordance with regulations. Monitoring surveillance capsules attached to neutron shield wall of outer core are consists of impact sample, tensile sample and temperature monitor
2007-05-10
International Nuclear Information System (INIS)
The regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from January 7 to February 8, 1985. The summary of the results of this regular inspection is as follows. The facilities as the object of inspection were radiation control facilities and waste facilities. On these facilities as the object of inspection, the appearance, disassembling, functional, performance and other inspections were carried out, and as the results, abnormality was not found at all. The works related to this regular inspection were accomplished within the range of the allowable radiation dose based on the relevant laws. (Kako, I.).
1986-01-01
Nuclear material accountability by isotope dilution mass spectrometry
International Nuclear Information System (INIS)
This paper discusses the mass spectrometric system that has been developed at the ICPP (Idaho Chemical Processing Plant) to meet the multiple constraints of U accountability, high sample load, and plant process control. The measurement system must produce high-quality accountability results while maintaining high sample throughput and reasonable turnaround time. The mass spectrometric system that has evolved to meet these demands includes extensive operator training, routine quality control checks, and continuing review of performance. 7 refs.
1981-07-13
Energy Technology Data Exchange (ETDEWEB)
Voestalpine AG (Linz, Austria) produces heavy steel for steam turbines, compressors for the promotion of oil and gas as well as for the chemical industry, mechanical engineering and for the offshore technology. A weight range between 1 and 200 tons can be covered. The author of the contribution under consideration is limited to characteristics which have to be managed by a large steel foundry within the range of the steam power plants. This is described on the basis of produced steam turbines for power stations in the highest performance segment (1,600 MW).
2010-07-01
Key methods for sustaining quality engineering data in nuclear power plants
International Nuclear Information System (INIS)
This paper discusses key methods for sustaining quality engineering data, the fundamental principles that these methods are based on, and the methods for supporting the performance of nuclear power plants by the provision of quality engineering data at all times. The concept of an 'engineering data foundation', and a Configuration Management data model are developed. The concepts and methods for managing the integrity of engineering data across many different databases and document systems are developed, including the key concepts of data-positions and data-values, Master Data and Copy Data, and the concept of a 'partnership between people and technology'. (author). 7 refs., 1 tab., 2 figs.
1995-06-04
Instrumentation, controls and automation in the power industry. Volume 45
Energy Technology Data Exchange (ETDEWEB)
Sessions covered economic and management, advance control technologies (including pulverized coal dynamic balancing-activator and control strategy by B. DeMarcy and X.Ollat), nuclear technologies, environmental (including purge considerations for seasonal SCR systems by D.P. Evely, NOx and heat rate supervisory control at NRG-Huntley operations by G Lange, comparison of gypsum dewatering technologies at flue gas desulfurization plants by B.A. Perlmutter, beta gauge particulate monitoring by J.L. Arnold), improving performance at nuclear power plants, network security, and emerging applications.
2002-07-01
Environmental Research Database
DescriptionThis project aims to develop a hybrid bioremediation/phytoremediation process for sustainable in- situ treatment of hydrocarbon contaminated soils, centred on 3 tenets: 1) Application of wood-chip derived compost enriched with white rot fungi for primary bioremediation; 2) Growth of pre-selected plant species for secondary phytoremediation; 3) Use of stress- adapted mycorrhizal fungi to maximise plant performance. A multidisciplinary approach is essential to optimise bioremediation for the trea [continued...
2008-01-14
Energy Technology Data Exchange (ETDEWEB)
This document contains the accident sequence analysis of internally initiated events for Grand Gulf, Unit 1 as it operates in the Low Power and Shutdown Plant Operational State 5 during a refueling outage. The report documents the methodology used during the analysis, describes the results from the application of the methodology, and compares the results with the results from two full power analyses performed on Grand Gulf.
1994-06-01
Energy Technology Data Exchange (ETDEWEB)
A special study was conducted to investigate the influences of minimum approach temperature differences occurring in supercritical-heater/vaporizer and evaporative-condenser heat rejection systems on geothermal-electric binary power plant performance and cost of electricity. For the systems investigated optimum pinch points for minimizing cost of electricity were estimated to range from 5 to 7/sup 0/F for the heater vaporizer. The minimum approach of condensing temperature to wet-bulb temperature for evaporative condensers was estimated to be about 30/sup 0/F in order to achieve the lowest cost of electricity.
1983-10-01
Development of the EE-1 small community solar thermal power system
The development status of the EE-1 Small Community Solar Thermal Power Experiment (SCSE Program) is presented. Current activities on the Phase II single module development effort are presented, together with plans for a Phase III 1 MW/sub e/ demonstration plant. A description of the various subsystems and components is given with a brief review of their development background. Latest performance figures are given for a 1 MW/sub e/ plant, based on 56 power modules, each consisting of a 12m parabolic dish concentrator, a cavity receiver, an organic Rankine power conversion subsystem and a ground-mounted solid-state rectifier.
1981-01-01
Development of Tsunami PSA method for Korean NPP site
International Nuclear Information System (INIS)
A methodology of tsunami PSA was developed in this study. A tsunami PSA consists of tsunami hazard analysis, tsunami fragility analysis and system analysis. In the case of tsunami hazard analysis, evaluation of tsunami return period is major task. For the evaluation of tsunami return period, numerical analysis and empirical method can be applied. The application of this method was applied to a nuclear power plant, Ulchin 56 NPP, which is located in the east coast of Korean peninsula. Through this study, whole tsunami PSA working procedure was established and example calculation was performed for one of real nuclear power plant in Korea
2010-10-01
Energy Technology Data Exchange (ETDEWEB)
The authors have developed a complex of activation methods of analysis using a nuclear reactor (nuclear activation analysis) and a cyclotron (charged-particle activation analysis). The methods have been used to determine the concentrations of more than 20 elements in five medicinal plants native to Uzbekistan: Syrian rue (Peganum harmala L.), plantain (Plantago lanceolata), peppermint (Mentha piperata L.), sage (Salvia officinalis L.), and ziziphora (Ziziphora bungeana Yur.). The results of radio-activation analysis were compared with the results of standard spectral analysis performed in another laboratory and the accuracy of the procedures developed was evaluated on the basis of the results.
1987-06-01
Energy Technology Data Exchange (ETDEWEB)
The profitability of combustion turbines intended for export is of extreme importance for Electricite de France. It is principally during the development phase of a project that one can ensure resect of two indissociable factors, essential to the per-kWh production cost: global operating costs and performance in terms of reliability and availability. The approach proposed here advocates the global acquisition of the installation and its logistic support. Generally applicable recommendations are given. They enable integrating in the future plant specifications all requirements relative to plant reliability, availability, maintainability and logistic support. They are structured according to type: expression of needs and management factors. (orig.) 4 refs.
1998-12-31
ACTIVATION ANALYSIS OF MOLYBDENUM IN PLANT MATERIAL
The determination of molybdenum in plant material by activation analysis is described. Both activation to Mo/sup 99/ (t/sub 1/2/ = 66 hr) and to Mo/sup 101/ (t,sub 1/2/ = 14.6 min) is used. With th e latter method the whole analysis takes about 1 hr. The extraction of molybdenum is carried out from a sulfuric acid medium using tri-n-octylamine in kerosene. The analysis was performed on clover (trifolium sp.) and the results agree with those obtained by colorimetry using the thiocyanate method. (auth)
1962-03-01
Modeling and evaluation of externally fired combined cycle using ASPEN
Energy Technology Data Exchange (ETDEWEB)
A new performance model of the externally fired combined cycle (EFCC) is implemented in ASPEN (Advanced System for Process ENgineering), a chemical process simulator. The model accounts for interactions within and between approximately a dozen major process areas. The new model is applied to case studies to evaluate the sensitivity of process performance to the ranges of uncertainty in key model inputs such as heat losses, carbon conversion, and air leakage rates, and to illustrate how alternative designs, including steam injection and flue gas desulfurization (FGD), can affect plant thermal efficiency and net power output. The model results suggest that careful attention to the design of the FGD system is needed, especially with respect to reheat, and that steam injection may offer cost savings associated with reducing the size of the steam turbine with little or no penalty on plant output or ...
1997-12-01
International Nuclear Information System (INIS)
One of the initial stages in ecological risk assessment for hazardous waste sites is the screening of contaminants to determine which of them are worthy of further consideration as ''contaminants of potential concern.'' This process is termed ''contaminant screening.'' It is performed by comparing measured ambient concentrations of chemicals to benchmark concentrations. Currently, no standard benchmark concentrations exist for assessing contaminants in soil with respect to their toxicity to plants. This report presents a standard method for deriving benchmarks for this purpose (phytotoxicity benchmarks), a set of data concerning effects of chemicals in soil or soil solution on plants, and a set of phytotoxicity benchmarks for 34 chemicals potentially associated with US Department of Energy (DOE) sites. Chemicals that are found in soil at concentrations exceeding both the phytotoxicity benchmark and the background ...
Measures for reliability improvement of on-site power plant at steel works
Energy Technology Data Exchange (ETDEWEB)
This report describes the arrangement and features of the Ogishima thermal power plant facilities, as well as activities being performed there for operation control, regular inspection and improvement in reliability. The power plant uses about 48 percent of the by-product gas as its fuel to supply about 81 percent of the required power. Operation of the No. 1 unit started in 1976. Currently, the plant has three units, each with an output of 125MW. Each unit consists of a natural circulation boiler with a maximum evaporation capacity of 410 ton/hour and a reheat regenerative condensing turbine with a main vapor pressure of 127 kg/cm/sup 2/G. Techniques used for water properties control and combustion control are also described. In the plant, convetional time management integrity techniques are now being replaced by state management integrity techniques that determines the ...
1988-04-15
Gas fired combined cycle plant in Singapore: energy use, GWP and cost-a life cycle approach
Energy Technology Data Exchange (ETDEWEB)
A life cycle assessment was performed to quantify the non-renewable (fossil) energy use and global warming potential (GWP) in electricity generation from a typical gas fired combined cycle power plant in Singapore. The cost of electricity generation was estimated using a life cycle cost analysis (LCCA) tool. The life cycle assessment (LCA) of a 367.5 MW gas fired combined cycle power plant operating in Singapore revealed that hidden processes consume about 8% additional energy in addition to the fuel embedded energy, and the hidden GWP is about 18%. The natural gas consumed during the operational phase accounted for 82% of the life cycle cost of electricity generation. An empirical relation between plant efficiency and life cycle energy use and GWP in addition to a scenario for electricity cost with varying gas prices and plant efficiency have been established.
2005-08-15
Gas fired combined cycle plant in Singapore: energy use, GWP and cost-a life cycle approach
International Nuclear Information System (INIS)
A life cycle assessment was performed to quantify the non-renewable (fossil) energy use and global warming potential (GWP) in electricity generation from a typical gas fired combined cycle power plant in Singapore. The cost of electricity generation was estimated using a life cycle cost analysis (LCCA) tool. The life cycle assessment (LCA) of a 367.5 MW gas fired combined cycle power plant operating in Singapore revealed that hidden processes consume about 8% additional energy in addition to the fuel embedded energy, and the hidden GWP is about 18%. The natural gas consumed during the operational phase accounted for 82% of the life cycle cost of electricity generation. An empirical relation between plant efficiency and life cycle energy use and GWP in addition to a scenario for electricity cost with varying gas prices and plant efficiency have been established.
2005-08-01
International Nuclear Information System (INIS)
Over the past few years, NPCIL has performed comprehensive Level-1 Probabilistic Safety Assessment (PSA) for a 220 MWe Pressurised Heavy Water Reactor (PHWR) at Kakrapar Atomic Power Station (KAPS) and for the first 540 MWe PHWR at Tarapur Atomic Power Project (TAPP- 3 and 4). The major objective of these PSAs was to present an integrated picture of the safety of the plant to identify and understand key plant vulnerabilities. As a result of the availability of these PSAs, there is a desire to use them to operate the plants in the most efficient manner practicable. In recent years, the operation of Indian Nuclear Power Plants has been characterized by improved availability/capacity factors and reduced forced outages. Frequency of planned outages is also being reduced. In order to achieve this, the PSAs are now being used as an engineering tool for optimization of Technical ...
2005-12-01
Automated method for determining location and magnitude of leaks inside a PWR containment
Energy Technology Data Exchange (ETDEWEB)
Thermal-hydraulics analysis can be used to determine location and magnitude of leaks inside a pressurized water reactor (PWR) containment, as required by plant technical specifications. The major advantage of this detection method is that it minimizes radiation exposure of maintenance personnel because most of the leak detection process is performed from the control room outside the containment. In addition, such a program allows for the elimination of pipe whip restraints and jet impingement shields, eliminating costs for maintenance of these supports and shields in older plants and lowering construction costs for new plants. Previously, only simple single-node containment models were used for determining leakage magnitude. This paper presents a more sophisticated multinode approach for determining the magnitude and location. The resulting sensitivities to leak can be programmed into the ...
1986-01-01
An aerial radiological survey of the Portsmouth Gaseous Diffusion Plant and surrounding area
International Nuclear Information System (INIS)
An aerial radiological survey was conducted from August 10-16, 1993, over a 78-square-kilometer (30-square-mile) area of the Portsmouth Gaseous Diffusion Plant and surrounding area located near Portsmouth, Ohio. The survey was performed at a nominal altitude of 46 meters (150 feet) with a line spacing of 76 meters (250 feet). A contour map of the terrestrial gamma exposure rate extrapolated to 1 meter above ground level was prepared and overlaid on a set of United States Geological Survey topographic maps of the area and an aerial photograph of the plant. The terrestrial gamma exposure rates varied from about 7 to 14 microroentgens per hour at 1 meter above the ground. Protactinium-234m was observed at six sites within the boundaries of the plant. At a seventh site, only uranium-235 was observed. No other man-made, gamma ray-emitting radioactive material was present in a detectable quantity, either on ...
2005-05-01
AP1000 plant construction in China: Ansaldo Nucleare contribution
International Nuclear Information System (INIS)
On 24th of July 2007 Westinghouse Electric Co. signed landmark contracts with China's State Nuclear Power Technology Corporation (SNPTC), to provide four AP1000 nuclear power plants in China. The AP1000 is a two-loop 1117 MWe Pressurized Water Reactor (PWR). It is based on proven technology, but with an emphasis on safety features that rely on natural driving forces, such as pressurized gas, gravity flow, natural circulation flow and convection. Ansaldo Nucleare has provided a significant support to the passive plant technology development and, starting from 2000, is cooperating with Westinghouse to development of the AP1000 Plant. In the frame of the AP1000 Chinese agreement, Ansaldo Nucleare, in Joint Venture with Mangiarotti Nuclear, has signed a contract with Westinghouse for the design and the supply of innovative components to be installed in the first AP1000 unit to be constructed at the Sanmen site. The contract ...
2009-10-12
A habitat template approach to green building surfaces
Energy Technology Data Exchange (ETDEWEB)
The use of entire plant communities of native species is gaining interest in the green roof industry. Plant communities must be matched with environmental conditions that mimic conditions in their original habitats. Urban built environments do not differ significantly from the rocky outcrops with poor, shallow soil that many plants colonize. This paper provided details of an experiment investigating the impact of plant community structure and species diversity on living roof performance. The aim of the experiment was to determine the impact of species diversity on precipitation interception, nutrient retention, temporal biomass constancy and roof temperature constancy. The diversity treatment included separate monocultures of 8 species in the community, randomly determined mixtures of 4 species, and a mixture of all 8. Functional groups included mosses, liverworts, colonial algae ...
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
In the frame of the comprehensive assessment of Swiss energy systems, air quality simulations were performed by using a 3-dimensional photo-chemical dispersion model. The objective is to investigate the impacts of pollutants in Switzerland for future options of Swiss energy systems. Four scenarios were investigated: Base Case: simulations with the projected emissions for the year 2030, Scenario 1) all nuclear power plants were replaced by oil-driven combined cycle plants (CCP), Scenarios 2 to 4) traffic emissions were reduced in whole Switzerland as well as in the cities and on the highways separately. Changes in the pollutant concentrations and depositions, and the possible short-term impacts are discussed on the basis of exceedences of critical levels for plants and limits given to protect the public health. (author) 2 figs., 7 refs.
1999-08-01
FFTF operating experience, 1982-1984
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a 400 Mwt sodium-cooled fast reactor operating at the Hanford Engineering Development Laboratory, Richland, Washington, to conduct fuels and materials testing in support of the US Liquid Metal Fast Breeder Reactor (LMFBR) program. Startup and initial power testing included a comprehensive series of nonnuclear and nuclear tests to verify the thermal, hydraulic, and neutronic characteristics of the plant. A specially designed series of natural circulation tests were then performed to demonstrate the inherent safety features of the plant. Early in 1982, the FFTF began its first 100-day irradiation cycle. Since that time the plant has operated very well, achieving a cycle capacity factor of 94% in the most recent irradiation cycle. Seventy-five specific test assemblies and 25,000 individual fuel pins have been irradiated, some in excess of 80 MWd/Kg.
1984-04-09
International Nuclear Information System (INIS)
The biota of the Mississippi River in an ecological recovery zone near Red Wing, MN was studied before and after start-up of a nuclear plant to acquire baseline data and to estimate changes due to thermal addition. Thermal addition produced significant decreases in primary production in a plant region during summer month periods when water temperatures were near 36C. Extensive fisheries studies and sonar tagging/tracking of S. vitreum were performed. Comparison of fisheries results with other riverine, lake, and pond studies indicated a favorable environment for the success of the fish species studied. Qualitative macroinvertebrate surveys were conducted.
Efficiency study of different photovoltaic plant connection schemes under dynamic shading
Energy Technology Data Exchange (ETDEWEB)
An important growth in the power of the photovoltaic systems connected to a grid has recently been observed. In spite of the advances in module technology, the problems in the system design increased, especially regarding the surface of the earth they occupy. In this work we propose a complete model for plant simulation with different wiring diagrams and under dynamic shading. Results obtained from simulations showed that the configuration with the lowest performance was that of only one serial-parallel group, whereas the highest efficiency corresponded to a design of groups of modules in parallel connected then in series. In general, a higher efficiency was obtained diminishing the quantity of modules in series and increasing their number in parallel. The simulation model proposed allows exploring different alternatives of wiring modules and finding the most efficient configurations for photovoltaic plants of medium and ...
2010-06-15
Energy Technology Data Exchange (ETDEWEB)
Explosives have rarely been used in decommissioning of nuclear reactors. Nevertheless, controlled blasting can be used advantageously during careful destruction of nuclear power plants for removal of concrete, pipe systems, and other components. Experiments performed within a former nuclear power plant demonstrate the feasibility of this method, employing explosive masses up to 15 kg per blast. The loadings of the components and the total plant structure were measured and compared with code predictions. The experiments show a response of the containment predominantly in frequency ranges above 100 Hz, thus keeping the building and components below German regulation limits for shock excitation. The blast wave pressures are reduced drastically within short distances in the building. Dust and debris can be contained with simple methods such as curtains. Use of this method seems to be applicable to actual ...
1989-08-01
Chemical Defense and the Persistence of Pioneer Plant Seeds in the Soil of a Tropical Cloud Forest:
British Library Electronic Table of Contents (United Kingdom)
ABSTRACT We present evidence that differences in soil seedbank persistence among pioneer plants in the cloud forest of Monteverde, Costa Rica, are influenced by differences in seed chemical defense. We used extracted seed chemicals from Bocconia frutescens (Papaveraceae), Guettarda poasana (Rubiaceae), Phytolacca rivinoides (Phytolaccaceae), Urera elata (Urticaceae), Cecropia polyphlebia (Cecropiaceae), and Witheringia meiantha (Solanaceae) to assess seed chemical defense in two ways: (1) a plant pathogen inhibition assay using Pythium irregulare; and (2) a brine shrimp toxicity assay using Artemia salina. The combined performance of each species in the two assays positively correlated with seedbank persistence. In the pathogen assay, mycelium growth was reduced when Pythium was cultured o...
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
A study of advancements in power plant designs for use at geothermal resources in the low to moderate (300 to 400F) temperature range is reported. In 3 case studies, the benefits of R and D to achieve these advancements are evaluated in terms of expected increases in installed geothermal generating capacity over the next 2 decades. A parametric sensitivity study is discussed which analyzes differential power development for combinations of power plant efficiency and capitol cost. Affordable tradeoffs between plant performance and capital costs are illustrated. The independent review and analysis of the expected costs of construction, operation and maintenance of the Heber Binary Cycle Geothermal Power Demonstration Plant are described. Included in this assessment is an analysis of each of the major cost components of the project, including (1) construction cost, (2) well field ...
1983-06-30
Energy Technology Data Exchange (ETDEWEB)
The Heat Cycle Research Program, which is conducted for the Department of Energy, has as its objective the development of the technology for effecting the improved utilization of moderate temperature geothermal resources. The current testing involves the investigation of binary power cycle performance utilizing mixtures of non-adjacent hydrocarbons as the working fluids, with supercritical vaporization and in-tube condensation of the working fluid. The utilization of these concepts verified here will improve the net geofluid effectiveness (net watt hours plant output per pound of geofluid) about 20% over that of a conventional binary power plant. The major effect in this improvement is the ability to achieve integral, countercurrent condensation. Results are presented for the recent testing including those tests examining the performance of the countercurrent condenser at different tube inclinations and ...
1988-01-01
First and second law analysis of diesel engine powered cogeneration systems
International Nuclear Information System (INIS)
In this article, the thermodynamic analysis of the existing diesel engine cogeneration system is performed. All necessary data are obtained from the actual diesel engine cogeneration plant located at Gaziantep, Turkey. The exergy analysis is aimed to evaluate the exergy destruction in each component as well as the exergetic efficiencies. The thermodynamic performance of a 25.32 MW electricity and 8.1 tons/h steam capacity diesel engine cogeneration system at full load conditions is analyzed. The thermal efficiency of the overall plant is found to be 44.2% and the exergetic efficiency is 40.7%. The exergy balance equations developed in this paper may also be utilized in the exergoeconomic analysis to estimate the production costs depending on various input costs in a diesel cogeneration system.
2008-08-01
First and second law analysis of diesel engine powered cogeneration systems
British Library Electronic Table of Contents (United Kingdom)
In this article, the thermodynamic analysis of the existing diesel engine cogeneration system is performed. All necessary data are obtained from the actual diesel engine cogeneration plant located at Gaziantep, Turkey. The exergy analysis is aimed to evaluate the exergy destruction in each component as well as the exergetic efficiencies. The thermodynamic performance of a 25.32MW electricity and 8.1tons/h steam capacity diesel engine cogeneration system at full load conditions is analyzed. The thermal efficiency of the overall plant is found to be 44.2% and the exergetic efficiency is 40.7%. The exergy balance equations developed in this paper may also be utilized in the exergoeconomic analysis to estimate the production costs depending on various input costs in a diesel cogeneration syste...
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
Experience with the identification and tuning of exciter constants for a generating unit as the Second Nuclear Power Plant of Taiwan Power Company is reported. Field test is first performed on the excitation system with the generator open-circuited. Since the field test results differ from the computer simulation results using manufacturer`s constants, the authors first modify the manufacturer`s constants based on their previous experience to reach a preliminary set of parameters for the excitation system. Then a hybrid nonlinear simulation-sensitivity matrix method is developed to further refine the excitation system parameters. The exciter constants are tuned in order to give better dynamic response before a power system stabilizer is applied to the generator. Field tests are then performed in order to compare the dynamic response of the generator without and with power system stabilizer.
1996-05-01
International Nuclear Information System (INIS)
Experience with the identification and tuning of exciter constants for a generating unit as the Second Nuclear Power Plant of Taiwan Power Company is reported. Field test is first performed on the excitation system with the generator open-circuited. Since the field test results differ from the computer simulation results using manufacturer's constants, the authors first modify the manufacturer's constants based on their previous experience to reach a preliminary set of parameters for the excitation system. Then a hybrid nonlinear simulation-sensitivity matrix method is developed to further refine the excitation system parameters. The exciter constants are tuned in order to give better dynamic response before a power system stabilizer is applied to the generator. Field tests are then performed in order to compare the dynamic response of the generator without and with power system stabilizer.
1995-07-23
Assessment of MCNP-4B code using measurement data of Wolsung nuclear power plant 2
International Nuclear Information System (INIS)
The benchmark calculations have been performed for MCNP-4B code using the measurement data of Wolsong nuclear power plant 2. In this study, the benchmark calculations have been performed for the criticality, boron worth, reactivity device worth, reactivity coefficient, and flux scan. Cross-section libraries were newly generated from ENDF/B-VI release 3 through NJOY97.114 data processing system and a three-dimensional full core model was developed for MCNP calculation. The simulation results have shown that the criticality is estimated within 4 mkn and the estimated reactivity worth of the control devices are generally consistent with the measurement data. In certain cases, the simulation results have shown large discrepancies against the measurement data, which will be sturdied further in the near future.
2001-05-01
A study on the transient piping vibration of power plant. Secondary piping system of Wolsung 1 unit
Energy Technology Data Exchange (ETDEWEB)
In order to maintain a safe operation and availability of generating facilities, qualitative and quantitative assessment of piping vibration was performed vibration sources and damages of piping support was identified on the second piping system of Wolsung nuclear power plant unit 1 .Inspected piping supports and structures in both hot and cold condition .Established evaluation procedures of piping vibration .Performed the static analysis of 2 nd piping system .Established optimal vibration reducing method .The measured vibration level after installing rigid supports and energy absorbing type restraint was reduced about 7 times in velocity unit (author). 24 refs., 95 figs.
1996-08-01
Energy Technology Data Exchange (ETDEWEB)
This month, the Cofrentes Nuclear Power Plant celebrates its 18th year of operation, this path is supported rom source by excellent operating results and is cause for the professional pride of those who throughout the years, have been involved on a day to-day basis is its evolution. This article describes the Plant's most significant milestones from the time of its construction up to the present. The different sections cover everything from the most relevant performance indicators to such specific aspects as optimization of refueling times. (Author)
2002-07-01
International Nuclear Information System (INIS)
The history of the technical, economic, and financial performances of these four countries' power companies over the past two decades is recounted, and then interpreted as the result of the existing organizational models. The changes that have occurred can be understood in long-term perspective by comparing the performance of these companies to the characteristics, rules, and objectives used to define the models, which also helps explain the history of performance indicator variations. Two models are defined: one for the physical plant and one for the management. These correspond to two successive phases in the organization and operation of the electrical sector. Rural electrification and regional interconnection will be important factors in any new model or models developed for the future, because the forms they take is likely to modify the characteristics of these national power companies. 26 refs., 1 ...
Energy Technology Data Exchange (ETDEWEB)
The performance of different polymers used to flocculate red mud particulate materials in the Bayer process can be evaluated on the basis of their efficiency to achieve adequate settling velocities and turbidity levels. In this study, three commercially available flocculants are evaluated under typical conditions found in the last washer of a Bayer plant. The different shear levels are produced by using a modified Couette flow system. Great differences are noticed in the performance of the polymers when they are compared at different dosages and at different shear rate levels. The data collected also suggests that conventional cylinder settling tests may not be adequate to measure the performance of certain types of polymers. (author)
2002-07-01
International Nuclear Information System (INIS)
The performance of different polymers used to flocculate red mud particulate materials in the Bayer process can be evaluated on the basis of their efficiency to achieve adequate settling velocities and turbidity levels. In this study, three commercially available flocculants are evaluated under typical conditions found in the last washer of a Bayer plant. The different shear levels are produced by using a modified Couette flow system. Great differences are noticed in the performance of the polymers when they are compared at different dosages and at different shear rate levels. The data collected also suggests that conventional cylinder settling tests may not be adequate to measure the performance of certain types of polymers. (author)
2002-08-11
Advances in human reliability analysis in Mexico
Energy Technology Data Exchange (ETDEWEB)
Human Reliability Analysis (HRA) is a very important part of Probabilistic Risk Analysis (PRA), and constant work is dedicated to improving methods, guidance and data in order to approach realism in the results as well as looking for ways to use these to reduce accident frequency at plants. Further, in order to advance in these areas, several HRA studies are being performed globally. Mexico has participated in the International HRA Empirical study with the objective of -benchmarking- HRA methods by comparing HRA predictions to actual crew performance in a simulator, as well as in the empirical study on a US nuclear power plant currently in progress. The focus of the first study was the development of an understanding of how methods are applied by various analysts, and characterize the methods for their capability to guide the analysts to identify potential human failures, and associated causes and ...
2010-10-15
Status of steam generators in Spain
International Nuclear Information System (INIS)
There are a total of nine operational nuclear plants in Spain totalling 7.350 MWe. These units produced 54.265 x 106 KWh in 1990, 36% of the total generation in Spain. Seven of these plants are of the PWR type. The first plant in operation was Jose Cabrera (ZORITA) in 1968, one loop Westinghouse plant with a model 24 Steam Generator. Due to the design margin and careful operation of the Steam Generator of this plant its performance have been very good, with only 5% tubes plugged after 23 years of operation. This is one of the few units in the world that remains in phosphate chemistry. During the period 1981-1985 a total of four units, two in Almaraz and two in Asco entered in operation. These three loop s Westinghouse units use model D-3 preheater Steam Generators. The poor design and manufacture of the Steam Generators of these units have caused a large number ...
1991-09-16
Influence of organizational factors on performance reliability
International Nuclear Information System (INIS)
This is the first volume of a two-volume report. Volume 2 will be published at a later date. This report presents the results of a research project conducted by Brookhaven National Laboratory for the United States Nuclear Regulatory Commission, Office of Nuclear Regulatory Research. The purpose of the project was to develop a general methodology to be use in the assessment of the organizational factors which affect performance reliability (safety) in a nuclear power plant. The research described in this report includes the development of the Nuclear Organization and Management Analysis Concept (GNOMIC). This concept characterizes the organizational factors that impact safety performance in a nuclear power plant and identifies some methods for systematically measuring and analyzing the influence of these factors on safety performance. This report is divided into two parts; Part 1 ...
International Nuclear Information System (INIS)
The analysis for priority rankings of the recommendations to reduce the total core damage frequency (CDF) of Wolsong nuclear power plant units 2/3/4 was performed in this paper. In order to derive the recommendations, the sensitivity analysis of CDF on which major contributors effect was performed based on the accident quantification results during Level 1 probabilistic safety assessments (PSA). Priorities were ranked in the way that compares the CDF reduction rate with the efforts required to implement those recommendations using risk matrix.
1998-05-01
A twin unidirectional impulse turbine for wave energy conversion
British Library Electronic Table of Contents (United Kingdom)
A twin unidirectional impulse turbine has been proposed in order to enhance the performance of wave energy plant. This turbine system uses two unidirectional impulse turbines and their flow direction is different from each other. However, the turbine characteristics have not been clarified to date. The performances of a unidirectional impulse turbine under steady flow conditions were investigated experimentally by using a wind tunnel with large piston/cylinder in this study. Then, efficiency of the twin impulse turbine have been estimated by a quasi-steady analysis using experimental results.
2011-01-01
Load-following operation of PWR plants
Energy Technology Data Exchange (ETDEWEB)
The load-following operation of nuclear power plants will become inevitable due to the increased nuclear share in the total electricity generation. As a groundwork for the load-following capability of the Korean next generation PWRs, the state-of-the-art has been reviewed. The core control principles and methods are the main subject in this review as well as the impact of load-following operations on the fuel performance and on the mechanical integrity of components. To begin with, it was described what the load-following operation is and in what view point the technology should be reviewed. Afterwards the load-following method, performance and problems in domestic 900 MWe class PWRs were discussed, and domestic R and D works were summarized. Foreign technologies were also reviewed. They include Mode G and Mode X of Foratom, D and L bank method of KWU, the method using PSCEA of ABB-CE, and MSHIM of Westinghouse. The ...
1993-12-01
Energy Technology Data Exchange (ETDEWEB)
The primary methodology that is used for disposal of municipal solid waste is the use of land fills; 80--85% of the municipal solid waste (MSW) produced in the country currently is land filled. The two other disposal alternatives used are recycling and incineration. Waste-to-energy technology (WTE) which incinerates MSW to produce electricity and/or steam is attractive in other cases since it reduces landfill volume, reduces the consumption of fossil and other fuels, and produces a revenue stream from the sale of the electricity or steam. The gaseous effluents from landfills can also be used to fuel power plants. Recycling and material separation programs can have a substantial impact on the throughput and heating value of MSW collected and thus impact WTE plant economics; the magnitude of the impact will depend upon a number of factors such as what materials and what fraction are separated and recycled, the design of the WTE ...
1994-09-01
Experimental modelling of a pilot lignocellulosic pellets stove plant
Energy Technology Data Exchange (ETDEWEB)
Small-scale stoves, producing heat and hot water, are suited for domestic purposes. In order to optimise their efficiency when using lignocellulosic pellets, an important task is to do research on their real performance. The general behaviour depends on many operational factors (air flow and humidity, pressure, etc), dimension and pellet characteristics (moisture, size, raw material, density, friability, etc). In this paper, the first results and general performance of a 24 kW pellet fixed bed stove pilot plant are presented. The plant has been designed to study pellet combustion in the laboratory. The main targets are to reduce emissions of pollutants and to improve energy efficiency. Different situations can be simulated and tested due to its flexible design. Temperatures, pressures, flows and emissions are measured and analysed. An extensive study of different load conditions is presented through the ...
2004-12-01
Assessment of RELAP5/MOD3/CANDU"+ to Wolsung-1 D_2O leakage event
International Nuclear Information System (INIS)
In order to evaluate the integrated performance of RELAP5/MOD3/CANDU"+ for CANDU operational transient analysis, we assesed the code to the D_2O leakage event occurred at Wolsung-I, 600 MW(e) CANDU reactor, on Oct. 20, '94. D_2O leakage event was initiated by stuck opening of liquid relief valve No.4 in primary coolant pressure and level control system. Assessment calculation was performed for the plant transients up to 1000 seconds after the initiating event. Calculation results are compared with those measured in primary heat transport system, pressure and inventory control system and boiler secondary system. Comparison with the plant trip log shows that the RELAP5/CANDU"+ is able to simulate the plant transients properly, from which we can conclude that the RELAP5/CANDU"+ is validated for application to CANDU operational transient analysis. CANDU specific models used in the ...
2001-10-01
Ageing assessments with application of PSA Models
International Nuclear Information System (INIS)
One of the main applications of PSA studies is related to identification of the major key issues related to plant safety. In standard PSA one assumes a constant value for component failure rates by considering that the component doesn't experience any degradation that could affect its performance. Used in this manner, standard PSA tools do not adequately address important ageing issues, and this fact could have a significant impact on the conclusions drawn from PSA studies and applications, in conditions of operation of ageing plants. To obtain realistic results, it is necessary to consider in the PSA model the ageing effects, and to do that it is necessary to take into consideration the change in component failure rate as a function of component age. In case of ageing phenomena, this dependence causes the failure rate of a component (or a set of components) to increase in time as the component age increase. The paper ...
2009-10-12
State of coal gasification for production of fuel gas and synthesis gas
Energy Technology Data Exchange (ETDEWEB)
The fundamental principles of coal gasification are discussed including the reactions, their course and influencing parameters. Said principles are illustrated considering heat balance as well as process performance. Coal gasification processes are presented which are under development on a pilot plant scale or which are approved on an industrial scale.
1984-04-01
Physical modeling of flow control device test in intake structure
International Nuclear Information System (INIS)
The seawater in the intake structure flows into the large pump to with draw excess heat from the turbine steam condenser. In the intake structure of a nuclear power plant, undesirable pump operating characteristics such as vortices, impeller damages and non-uniform pump-approach flow around the pump bells take place frequently due to poorly-arranged intake geometry. In this study, physical modeling test was performed to predict the hydraulic phenomenon, and proposed flow control devices.
2000-05-01
Model tests on a semi-axial pump turbine
Energy Technology Data Exchange (ETDEWEB)
Due to their good hydraulic characteristic semi-axial pump turbines are used in the medium head range of pumped storage plants. This paper describes model tests performed on a semiaxial pump turbine model and shows the results of these tests. The aim of the model tests was the optimization of the hydraulic water passage, the measurement of the hydraulic characteristics over the whole operating range, the investigation of the cavitation behaviour, the investigation of the hydraulic forces and torques as well as the proof of the values guaranteed to the customer.
1984-03-01
Energy Technology Data Exchange (ETDEWEB)
The SRI International industrial team completed a subsystem and system parametric analysis, a 100-MW/sub e/ commercial plant conceptual design, a cost and performance analysis, and a commercial assessment. An executive summary is presented in this volume. (WHK)
1980-04-01
Energy Technology Data Exchange (ETDEWEB)
U.S. Department of Energy (DOE) Policy 450.4, Safety Management System Policy commits to institutionalizing an Integrated Safety Management System (ISMS) throughout the DOE complex as a means of accomplishing its missions safely. DOE Acquisition Regulation 970.5204-2 requires that contractors manage and perform work in accordance with a documented safety management system.
2000-01-10
Dynamic behavior of a solar-heated receiver of a gas turbine plant
Energy Technology Data Exchange (ETDEWEB)
The mainly nonstationary operation of a solar-heated receiver can be simulated with sufficient accuracy only if data about the dynamic behavior are available. For this reason, the dynamic behavior of a solar cavity receiver with parabolic dish collector is investigated. The development of a mathematical simulation considering heat transfer and storage processes is presented and the procedure for a numerical solution is illustrated. The performance of the calculation method is finally demonstrated by simulating the passage of a cloud.
1987-01-01
Dynamic behavior of a solar heated receiver of a gas turbine plant
Energy Technology Data Exchange (ETDEWEB)
The mainly instationary operation of a solar heated receiver can be simulated with sufficient accuracy only if data about the dynamic behavior are available. For this reason, the dynamic behavior of a solar cavity receiver with parabolic dish collector is investigated. The development of a mathematical simulation considering heat transfer and storage processes is presented and the procedure for a numerical solution is illustrated. The performance of the calculation method is finally demonstrated by simulating the passage of a cloud.
1986-01-01
Development of pressurized internally circulating fluidized-bed (PICFB) technology
Energy Technology Data Exchange (ETDEWEB)
After the completion of the 4MWth pilot plant of the Pressurizied Internally Circulating Fluidized-bed Boiler (PICFB), a total of 15 test runs, amounting to 2280 hours of operation, were concluded. The test results have confirmed the superior operating performance. Additionally, Ebara plans to develop a Pressurized Internally Circulating Fluidized-bed Gasifier (PICFG or Advanced PICFB). 8 figs.
1998-07-01
Corrosion resistant coatings for silicon carbide heat exchanger tubes: Topical report
Energy Technology Data Exchange (ETDEWEB)
This heat exchanger is a critical step in the development of the Externally Fired Combined Cycle power system, a direct-coal combustion power plant (gas turbine). SiC is the only material with the needed resistance to creep, thermal shock, and oxidation; however a protective coating is needed. Ten candidate materials were identified: alumina-based materials, materials stable with SiO, and low expansion materials. An initial screening study should be performed.
1996-09-01
Thermoeconomic analysis of power plants. Final report
Energy Technology Data Exchange (ETDEWEB)
In this report, the concept of exergy and the general methodology of the exergetic analysis and the thermoeconomic (combined exergetic and economic) analysis of energy conversion systems are presented. The THESIS (THermodynamic and Economc SImulation System) computer program used for these analyses is briefly described. Detailed mass, energy, exergy and money balances for a reference steam power plant (Harry Allen Station) are shown. The effect of the most important process parameters on the overall efficiency is investigated. A year-by-year and a levelized revenue requirement analysis are presented. The costs of exergy losses are compared with the capital costs and other expenses due to owning and operating each particular plant component. The question whether it is profitable to reduce the exergy losses by increasing these costs and vice versa is investigated. A cost sensitivity analysis including the effect of coal price and average annual ...
1984-08-01
The KSNPP risk-effect analysis of the digital safety-critical systems
Energy Technology Data Exchange (ETDEWEB)
The study was performed for evaluating the risk effect of digital systems on the total plant. Based on risk monitor, a fault tree model for the Korean Standard Nuclear Power Plants (KSNPP), we integrate the fault-tree models for Digital Plant Protection System (DPPS) and Digital Engineered SaFety Actuation System (DESFAS) which are the most important safety-critical I and C systems in the KSNPP. In this study, however, three important factors (the probabilities of manual actuation failure, the software failure probability, and the watchdog timer fault coverage) are treated as the variables of the sensitivity study because quantification methodologies for these factors are not developed yet. Not only the unavailability of digital safety-critical system itself, but also the risk effect of digital systems on the total plant should be assessed to prove the safety of digital systems. The ...
2004-02-01
Nuclear power and sustainable development
International Nuclear Information System (INIS)
In Romania, the nuclear power is an element of sustainable development, being competitive, efficient and viable in the market economy. Fuel supply is ensured as nuclear fuel is manufactured in the country out of local uranium resources available in Romania. As for the environmental protection, it is known that, unlike the thermal power plants, the nuclear power plants do not release sulfur and nitrogen oxides, carbon dioxide and do not generate slag and ashes. The operation of nuclear power units does not release pollutants and, accordingly, these stations can contribute to the limitation and the abatement of environmental pollution. After seven years of Cernavoda NPP Unit 1 operation, a facility for storing low and medium level nuclear fuel wastes was built at the plant site as well as an intermediate dry storage for spent nuclear fuel whose first modules were commissioned in July 2003. They shall provide safe storage ...
2003-07-01
Methods for the simulation of the operation, in one future year, of a fixed plant mix
Energy Technology Data Exchange (ETDEWEB)
Compares methods used at CEGB (UK), EdF (France), and ENEL (Italy) for generation planning studies with particular reference to those tools (or parts of them) that perform a yearly simulation of the generating system operation. Offers a short description of the composition of the 3 generating systems for a better understanding of the different philosophies employed. Comments on the frequency of utilization of the programs and on their main differences. Suggests that since the 3 systems show a tendency towards a more similar mix in the future (e.g. the percentage of hydro power plants will decrease both in the French and in the Italian system while the nuclear and coal base units will increase; all 3 systems will include an increasing share of pumped storage plants) the discussed planning problems will probably become common to the 3 systems. Predicts increasing importance of coal transportation problems for ENEL and EdF ...
1982-12-01
Heat pumps in urban space heating systems: Energy and environmental aspects
International Nuclear Information System (INIS)
A statistical survey is conducted of air pollution in the city of Rome (Italy) due to conventional building space heating systems burning fossil fuels. The survey identifies the annual consumption of the different fuels and the relative amounts of the various pollutants released into the atmosphere by the heating plants, e.g., sulfur and nitrogen oxides, carbon monoxide, etc. Comparisons are then made between the ratios of urban heating plant air pollutants produced per tonne of fuel employed and those for ENEL (Italian National Electricity Board) coal, oil and natural gas fired power plants, in order to demonstrate the better environmental performances of the utility operated energy plants. The building space heating system energy consumption and pollution data are then used in a cost benefit analysis favouring the retrofitting of conventional heating systems with heat pump systems ...
1991-01-01
Conceptual design of a medium scale lead-bismuth cooled fast reactor
International Nuclear Information System (INIS)
To seek for a promising concept of a heavy liquid metal coolant (HLMC) fast reactor plant, Japan Nuclear Cycle Development Institute and the electric utilities conducted conceptual design study on various types of plant concepts and compared these concepts based on technical feasibility and economical perspective. A comparative design study is performed on Lead-Bismuth cooled reactors with forced and natural convection cooling. Eliminating an intermediate cooling system makes the heat transport system simple and can decrease the amount of the weight of NSSS. Based on the estimation of the amount materials, the plant internal load etc., a construction cost of these plants are evaluated approximately 2/3 times of that of LWRs at present. And, the nitride fuel makes breeding ratio of 1.2 with 150 GWd/t of burnup. The results of unprotected event analyses such as UTOP and ULOF show that ...
2003-09-15
Quality assurance requirements for the reliability of nuclear power plants in developing countries
International Nuclear Information System (INIS)
Quality Assurance (QA) has not been taken very seriously in developing countries despite their having significant nuclear power programmes. This may affect plant reliability and demands that urgent and serious attention be given to the development and implementation of Quality Assurance programmes according to local conditions. Confusion has been created by the differences in definitions and interpretations of terminologies of Quality Assurance and Control. Problems have been aggravated by the lack of clearly defined responsibilities and accountabilities during the projects execution phases of site selection, data collection, design, equipment fabrication and construction, etc. Therefore, reliability of nuclear power plants in developing countries is relatively low. But whenever some programme of QA has been implemented it has helped to improve the plant performance. This is highlighted in this paper by ...
Energy Technology Data Exchange (ETDEWEB)
Norway is privileged with extensive resources of natural gas, oil and hydropower. Location of gas fired combined cycle (CC) power plants in Norway offers advantages due to the availability of natural gas from the Norwegian continental shelf and fairly low ambient temperatures, giving high fuel-to-electricity conversion efficiency. The continental shelf provides large storage capacity for CO{sub 2} in deep saline aquifers and in drained gas fields. In this paper the results of extensive work on CO{sub 2} capture carried out during the last years by Statoil in co-operation with several engineering contractors, are presented. The goal has been to develop a commercially viable concept for a combined cycle power plant including CO{sub 2} capture and sequestration. The main concept is based on CO{sub 2} capture from exhaust gas from a combined cycle power plant, using absorption by amine (MEA) solutions. The CO{sub 2} is ...
2001-07-01
Chalon/Saint-Marcel manufacturing plant; L'usine de Chalon/Saint-Marcel
Energy Technology Data Exchange (ETDEWEB)
AREVA is the world leader in the design and construction of nuclear power plants, the manufacture of heavy components, and the supply of nuclear fuel and nuclear services such as maintenance and inspection. The Equipment Division provides the widest range of nuclear components and equipment, manufactured at its two facilities in Jeumont, northern France, and St. Marcel, in Burgundy. The St. Marcel plant, set on 35 ha (87.5 acres) near Chalon-sur-Saone, was established in 1973 in a region with a long history of specialized metalworking and mechanical activities to meet the demand for non-military nuclear requirements in France. The site offers two advantages: - excellent facilities for loading and transporting heavy components on the Saone river, - it's proximity to other group sites. Since its completion in 1975, the Chalon/St. Marcel facility has manufactured all the heavy components for French pressurized water reactors (PWRs) ...
2008-07-01
VIPEX (Vital-area Identification Package EXpert) Software Verification and Validation
International Nuclear Information System (INIS)
The purposes of this report are (1) to perform a Verification and Validation (V and V) test for the VIPEX(Vital-area Identification Package EXpert) software and (2) to improve a software quality through the V and V test. The VIPEX was developed in Korea Atomic Energy Research Institute (KAERI) for the Vital Area Identification (VAI) of nuclear power plants. The version of the VIPEX which was distributed is 3.2.0.0. The VIPEX was revised based on the first V and V test and the second V and V test was performed. We have performed the following tasks for the V and V test on Windows XP and VISTA operating systems: ? Testing basic functions including fault tree editing ? Testing all kind of functions ? Research for update from Visual BASIC 6.0 to Visual BASIC 2008
2003-12-01
Influence of Pressurisation on SOFC Performance and Durability: ATheoretical Study
British Library Electronic Table of Contents (United Kingdom)
Abstract Hybrid power plants consisting of a solid oxide fuel cell (SOFC) and a gas turbine show high electrical efficiencies, however require pressurisation of the SOFC to several bar. This paper presents a theoretical investigation of the pressure influence on SOFC performance and durability. A two-dimensional elementary kinetic model is used to predict the performance of a single cell in the pressure range of 1-20-bar. The influence of pressure on thermodynamics, reaction kinetics, porous electrode diffusion, channel transport and efficiency is assessed. It was found that polarisation resistance decreases with increasing pressure due to increased diffusion through porous electrodes and a higher electrode surface coverage with reactant species. Furthermore, open-circuit voltage increases...
2011-01-01
ECONOMICS AND FEASIBILITY OF RANKINE CYCLE IMPROVEMENTS FOR COAL FIRED POWER PLANTS
Energy Technology Data Exchange (ETDEWEB)
ALSTOM Power Inc.'s Power Plant Laboratories (ALSTOM) has teamed with the U.S. Department of Energy National Energy Technology Laboratory (DOE NETL), American Electric Company (AEP) and Parsons Energy and Chemical Group to conduct a comprehensive study evaluating coal fired steam power plants, known as Rankine Cycles, equipped with three different combustion systems: Pulverized Coal (PC), Circulating Fluidized Bed (CFB), and Circulating Moving Bed (CMB{trademark}). Five steam cycles utilizing a wide range of steam conditions were used with these combustion systems. The motivation for this study was to establish through engineering analysis, the most cost-effective performance potential available through improvement in the Rankine Cycle steam conditions and combustion systems while at the same time ensuring that the most stringent emission performance based on CURC (Coal Utilization Research ...
2004-09-08
Energy Technology Data Exchange (ETDEWEB)
This work presents an analysis of the operation of a multi-cylinder, tubro charged, indirect injection diesel engine from a second-law analysis point of view. For this purpose, a single-zone thermodynamic model following the filling and emptying modelling technique is developed. A second-law analysis is performed in all parts of the diesel engine plant, which provides all the existing availability terms and accounts for the evaluation of every component`s irreversibilities. A complete second-law terms tabulation is given for the maximum speed-full load operation case, which is compared with its first-law counterpart. A detailed parametric study is performed in all parts of the diesel engine plant comprising the effects of speed and load on the availability terms in a range that covers the whole operation of the engine under turbocharged action. Various second-law (availability) terms such as indicated ...
1997-03-01
Results of 1st regular inspection of No.2 unit in Sendai Nuclear Power Plant
International Nuclear Information System (INIS)
This report presents results of the 1st regular inspection of the No.2 unit of the Sendai Nuclear Power Plant. It was carried out during the period from September 22, 1986, to December 24, 1986. The inspection covered the main unit of the nuclear reactor, facilities for the nuclear reactor cooling system, facilities for the instrumentation control system, fuel facilities, radiation control facilities, disposal facilities, nuclear reactor containment facilities, and emergency power generation system. Checking of appearance, disassemblage, leak and functions-performance of these facilities was conducted and no abnormalities were found. All operations involved in the inspection were performed under conditions within the permissible dose as specified in the applicable laws. No major modification work was carried out during the period of the regular inspection. The exposure dose measurements (total dose, average dose and maximum ...
1987-01-01
Results of 1st regular inspection of No. 2 unit in Sendai Nuclear Power Plant
Energy Technology Data Exchange (ETDEWEB)
This report presents results of the 1st regular inspection of the No. 2 unit of the Sendai Nuclear Power Plant. It was carried out during the period from September 22, 1986, to December 24, 1986. The inspection covered the main unit of the nuclear reactor, facilities for the nuclear reactor cooling system, facilities for the instrumentation control system, fuel facilities, radiation control facilities, disposal facilities, nuclear reactor containment facilities, and emergency power generation system. Checking of appearance, disassemblage, leak and functions-performance of these facilities was conducted and no abnormalities were found. All operations involved in the inspection were performed under conditions within the permissible dose as specified in the applicable laws. No major modification work was carried out during the period of the regular inspection. The exposure dose measurements (total dose, average dose and ...
1987-09-01
Performance Assessment of Physical Protection System at Wolsong Nuclear Power Plant using SAVI code
Energy Technology Data Exchange (ETDEWEB)
The 9/11 event in the U.S.A has increased international terror possibilities against nuclear facilities including nuclear power plants(NPPs). It is necessary to assess the performance of existing physical protection system(PPS) at nuclear facilities based on such malevolent acts. A PPS is a complex configuration of detection, delay, and response elements. Several techniques are available to analyze a PPS and evaluate its effectiveness. Sandia National Laboratory(SNL) in the USA was developed a System Analysis of Vulnerability to Intrusion (SAVI) computer code for this purpose. It is powerful software for evaluating the effectiveness of PPS against outsider threats. This study presents the performance assessment of the PPS at Wolsong NPP using SAVI code. The first is that the SAVI constructs the site-specific Adversary Sequence Diagram (ASD) of the PPS. This provides a methods of graphically representing the PPS composed of ...
2005-07-01
On the off-design of a natural gas-fired combined cycle with CO{sub 2} capture
Energy Technology Data Exchange (ETDEWEB)
During the last 15 years cycles with CO{sub 2} capture have been in focus, due to the growing concern over our climate. Often, a natural gas fired combined cycle with a chemical absorption plant for CO{sub 2} capture from the flue gases have been used as a reference in comparisons between cycles. Neither the integration of the steam production for regeneration of amines in the combined cycle nor the off-design behaviour of such a plant has been extensively studied before. In this paper, the integration of steam production for regeneration of the amines is modelled at design load and studied in off-design conditions for a combined cycle. Different ambient conditions and part-load strategies and their influence on the cycle performance are also examined. Of particular interest is a novel strategy with the possibility of longer life of gas turbine blading, with marginal loss in efficiency. The off-design ...
2007-04-15
Application of hydraulic network analysis to motor operated butterfly valves in nuclear power plants
International Nuclear Information System (INIS)
This paper presents the application of hydraulic network analysis to evaluate the performance of butterfly valves in nuclear power plant applications. Required actuation torque for butterfly valves in high-flow applications is often dictated by peak dynamic torque. The peak dynamic torque, which occurs at some intermediate disc position, requires accurate evaluation of valve flow rate and pressure drop throughout the valve stroke. Valve flow rate and pressure drop are significantly affected by the valve flow characteristics and the hydraulic system characteristics, such as pumping capability, piping resistances, single and parallel flow paths, system hydrostatic pressure, and the location of the motor-operated valve (MOV) within the system. A hydraulic network analysis methodology that addresses the effect of these parameters on the MOV performance is presented. The methodology is based on well-established engineering ...
1992-07-01
Geothermal heat cycle research: Supercritical cycle with horizontal counterflow condenser
Energy Technology Data Exchange (ETDEWEB)
The Heat Cycle Research Program, which is being conducted for the Department of Energy, has as its objective the development of the technology for effecting the improved utilization of moderate temperature geothermal resources. To meet this objective, the program has as one of its goals to improve the performance of geothermal binary cycles to levels approaching the practicable thermodynamic maximum. In pursuit of this goal, tests are being conducted at the Heat Cycle Research Facility located at the DOE Geothermal Test Facility, East Mesa, California. The current testing involves the investigation of binary power cycle performance utilizing mixtures of non-adjacent hydrocarbons as the working fluids, with supercritical vaporization and in-tube condensation of the working fluid. In addition to the present test program, preparations are being made to investigate the binary cycle performance improvements which can be achieved ...
1987-01-01
UMTRA project disposal cell cover biointrusion sensitivity assessment, Revision 1
International Nuclear Information System (INIS)
This study provides an analysis of potential changes that may take place in a Uranium Mill Tailings Remedial Action (UMTRA) Project disposal cell cover system as a result of plant biointrusion. Potential changes are evaluated by performing a sensitivity analysis of the relative impact of root penetrations on radon flux out of the cell cover and/or water infiltration into the cell cover. Data used in this analysis consist of existing information on vegetation growth on selected cell cover systems and information available from published studies and/or other available project research. Consistent with the scope of this paper, no new site-specific data were collected from UMTRA Project sites. Further, this paper does not focus on the issue of plant transport of radon gas or other contaminants out of the disposal cell cover though it is acknowledged that such transport has the potential to be a significant pathway for ...
2004-06-22
UMTRA project disposal cell cover biointrusion sensitivity assessment, Revision 1
Energy Technology Data Exchange (ETDEWEB)
This study provides an analysis of potential changes that may take place in a Uranium Mill Tailings Remedial Action (UMTRA) Project disposal cell cover system as a result of plant biointrusion. Potential changes are evaluated by performing a sensitivity analysis of the relative impact of root penetrations on radon flux out of the cell cover and/or water infiltration into the cell cover. Data used in this analysis consist of existing information on vegetation growth on selected cell cover systems and information available from published studies and/or other available project research. Consistent with the scope of this paper, no new site-specific data were collected from UMTRA Project sites. Further, this paper does not focus on the issue of plant transport of radon gas or other contaminants out of the disposal cell cover though it is acknowledged that such transport has the potential to be a significant pathway for ...
1995-10-01
Energy Technology Data Exchange (ETDEWEB)
A common practice of electric utilities experiencing transmission and distribution (T and D) system overloads is to expand the substation, add lines, or upgrade equipment, all of which are capital intensive options. In 1988, it was hypothesized that strategically sited photovoltaics (PV) could benefit parts of T and D systems near or at overloaded conditions. An evaluation methodology was developed and applied to a test case (Kerman Substation near Fresno, California). Analytical results suggested that the value of PV to the T and D system could substantially exceed its energy and generation capacity value. The importance of this finding indicated the need for empirical validation. This led to the construction of a 0.5 MW PV demonstration plant by Pacific Gas and Electric Company (PG and E) at Kerman, California as part of the PVUSA (PV for Utility Scale Applications) project. PVUSA is a national public-private partnership that is assessing and demonstrating the ...
1994-07-01
FFTF operational results: startup to 100 MWd/kg
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a 400-MW(t) sodium-cooled fast reactor operating at the Hanford Engineering Development Laboratory in Richland, Washington, to conduct fuels and materials testing in support of the US liquid-metal fast breeder reactor program. Startup and initial power testing included a comprehensive series of nuclear and nonnuclear tests to verify the thermal and neutronic characteristics of the plant and to demonstrate its inherent safety features. Extensive reactor core characterization measurements were completed to provide the neutron and gamma spectra, fission rates, and other physics data needed to design and evaluate tests irradiated in the FFTF. A specially designed series of natural-circulation tests was performed to demonstrate the inherent safety features of the plant. Early in 1982 the FFTF began its first 100-d irradiation cycle. Since that time the plant has operated ...
Energy Technology Data Exchange (ETDEWEB)
This thesis surveys the concepts of exergy and extends the exergy method of analysis from the standpoint of its applications to the power plant systems. After a brief historical review of exergy concepts, the general exergy equation is derived from the combined equation of First and Second Law, and it is shown that any special case of exergy equation is a simplified form of the general exergy equation. The mathematical method for the exergy analysis of a steady-state, steady-flow system, analogous to that of the First Law, is given. The exergy losses in a power plant are discussed. Then in order to examine these losses, the Second Law performance of major processes of combustion, compression, heat transfer, mixing and throttling have been analyzed analytically, and the exergy efficiencies are defined that accurately assess the thermodynamic performance of the corresponding processes. The methods for ...
1981-01-01
International Nuclear Information System (INIS)
Growing of PV for electricity generation is one of the highest in the field of the renewable energies and this tendency is expected to continue in the next years. Due to the various seasonal, hourly and daily changes in climate, it is relatively difficult to find a suitable analytic model for predicting the performance of a grid-connected photovoltaic (GCPV) plant. In this paper, an artificial neural network is used for modelling and predicting the power produced by a 20 kWp GCPV plant installed on the roof top of the municipality of Trieste (latitude 45 deg. 40'N, longitude 13 deg. 46'E), Italy. An experimental database of climate (irradiance and air temperature) and electrical (power delivered to the grid) data from January 29th to May 25th 2009 has been used. Two ANN models have been developed and implemented on experimental climate and electrical data. The first one is a multivariate model based on the solar irradiance ...
2010-12-01
ENGINEERING DEVELOPMENT OF COAL-FIRED HIGH-PERFORMANCE POWER SYSTEMS
Energy Technology Data Exchange (ETDEWEB)
A High Performance Power System (HIPPS) is being developed. This system is a coal-fired, combined cycle plant with indirect heating of gas turbine air. Foster Wheeler Development Corporation and a team consisting of Foster Wheeler Energy Corporation, Bechtel Corporation, University of Tennessee Space Institute and Westinghouse Electric Corporation are developing this system. In Phase 1 of the project, a conceptual design of a commercial plant was developed. Technical and economic analyses indicated that the plant would meet the goals of the project which include a 47 percent efficiency (HHV) and a 10 percent lower cost of electricity than an equivalent size PC plant. The concept uses a pyrolyzation process to convert coal into fuel gas and char. The char is fired in a High Temperature Advanced Furnace (HITAF). The HITAF is a pulverized fuel-fired boiler/air heater where steam is ...
1998-10-01
User's guide for the BNW-III optimization code for modular dry/wet-cooled power plants
Energy Technology Data Exchange (ETDEWEB)
This user's guide describes BNW-III, a computer code developed by the Pacific Northwest Laboratory (PNL) as part of the Dry Cooling Enhancement Program sponsored by the US Department of Energy (DOE). The BNW-III code models a modular dry/wet cooling system for a nuclear or fossil fuel power plant. The purpose of this guide is to give the code user a brief description of what the BNW-III code is and how to use it. It describes the cooling system being modeled and the various models used. A detailed description of code input and code output is also included. The BNW-III code was developed to analyze a specific cooling system layout. However, there is a large degree of freedom in the type of cooling modules that can be selected and in the performance of those modules. The costs of the modules are input to the code, giving the user a great deal of flexibility.
1984-09-01
System, economy and ecology viewpoints of the Krsko NPP lifetime extension
International Nuclear Information System (INIS)
Krsko NPP plant life extension was analysed and evaluated with respect to system, economy and ecology viewpoints. From the system perspective it was established that also in the extended lifetime the plant will remain in operation as a base load electricity supplier. The systematic review was performed to determine its overall competitiveness against advanced coal, gas and new nuclear units. The analysis considered also hydro and renewable sources. Analysis and evaluations resulted in the conclusion that the Krsko NPP lifetime extension is the most effective alternative for base load production due to small additional capital investments, low fuel costs, no new siting requirements, lowest climate and environmental impact, and reliable and safe operation. (author)
2007-09-10
Simulation and design of membrane plants with AspenPlus
Energy Technology Data Exchange (ETDEWEB)
In this paper the simulation of hybrid processes containing membrane units will be discussed. For this purpose a user-defined module for simulation and design of membrane processes was implemented into the simulation program AspenPlus. The advantages can be summarized as follows: - any combination of membrane processes with all other units already implemented in AspenPlus is possible, including internal recycle streams, - utilization of the physical property models and data bases of AspenPlus is possible, - cost and sensitivity analysis can be performed. These benefits are demonstrated in detail for a membrane vapor recovery unit for the treatment of tank farm off-gas, for a two-stage reverse osmosis plant for organic/-organic separations and for a combination of distillation and pervaporation for the separation of a dimethylcarbonate/methanol mixture. (orig.)
1996-10-01
Severe accident analysis for Wolsung nuclear power plants
Energy Technology Data Exchange (ETDEWEB)
Severe accident analysis has been performed for the Wolsung nuclear power= plants in Korea to investigate severe accident phenomena of CANDU-600 reactors as a part of Level II PSA study. The accident sequence analyzed in this paper is loss of active heat sinks (LOAH) which is caused by loss of off-site power, diesel generators, and DC power. ISAAC (Integrated Severe Accident Analysis Code) computer code developed by KAERI (Korea Atomic Energy Research Institute) was used in this analysis. This paper describes the important thermal-hydraulics and source term behaviors in the primary system and inside containment, and the failure mechanisms of calandria vessel and containment. In addition, some insights for accident management program (AMP) are also given. (Author) 5 refs., 1 tab., 12 figs.
1997-05-01
Recommended changes in meteorological measurement and prediction methods for coastal sites
Energy Technology Data Exchange (ETDEWEB)
A study was performed to examine currently recommended meteorological measurement programs and atmospheric transport and diffusion prediction models for nuclear power plants to determine their adequacy for plants located in coastal zones where meteorological conditions are normally more complex than at inland sites and to make recommendations for changes to improve current procedures. Recommendations were based on an extensive literature review and on studies of coastal meteorology and diffusion. The study was focused on the following areas: coastal internal boundary layers; tower location; instrument heights; atmospheric stability classification; plume meander; and diffusion calculations. Each of the areas is discussed with appropriate recommendations which were made with respect to either the scientific or the regulation aspects of current procedures or both. Other potential problem areas are also pointed out.
1980-01-01
Radiological operating experience at FFTF [Fast Flux Test Facility
International Nuclear Information System (INIS)
The Fast Flux Test Facility has been in operation for approximately five years, including about one thousand days of full power operation of the Fast Test Reactor. During that time the collective dose equivalents received by operating personnel have been about two orders of magnitude lower than those typically received at commercial light water reactors. No major contamination problems have been encountered in operating and maintaining the plant, and release of radioactive gas to the environment has been minimal and well below acceptable limits. All shields have performed satisfactorily. Experience to date indicates an apparent radiological superiority of liquid metal reactor systems over current light water plants.
1987-04-22
Power system stabilizer based on inverse dynamics using an artificial neural network
Energy Technology Data Exchange (ETDEWEB)
A stable power system stabilizer (PSS) based on the inverse dynamics of the controlled system using an artificial neural network (ANN) is suggested to enhance the dynamic performances of a power system. First, an output feedback control law is driven with some conditions satisfied, which guarantees the internal stability and robustness against the asymptotically stable external disturbances. Then the control law is implemented using the inverse dynamics of the controlled plant. The inverse dynamics of the controlled plant is identified by an ANN, inverse dynamics neural network (IDNN), off-line. The pole-shifting technique and a scaling factor are introduced for the control system to meet the conditions for internal stability and robustness. The proposed controller is applied to a typical single-machine infinite-bus power system. Simulation results under various operation conditions are given which show that the proposed ...
1996-06-01
PSA for CANDU-6 pressurized heavy water reactors: Wolson Units 2,3 and 4 of Korea
International Nuclear Information System (INIS)
Level 1 and 2 probabilistic safety assessments (PSAs) for both internal and external events are being performed to meet one of the conditions for a construction permit for Wolsong units 2, 3, and 4 in Korea. These units are CANDU-6 Pressurized Heavy Water Reactors (PHWRs), and the study is the first comprehensive level 1 and 2 PSAs for CANDU type plants in the world. The detailed PSA includes and extensive fault tree, event tree analysis, human reliability analysis, and common cause failure analysis. Event trees have been developed for 35 internal initiating event groups. The preliminary results show that the total core damage frequency for Wolsong units 2, 3, and 4 each is similar to that for a typical PWR plant. (author).
1997-06-01
NRC safety research in support of regulation, FY 1992. Volume 7
Energy Technology Data Exchange (ETDEWEB)
This report, the eighth in a series of annual reports, was prepared in response to congressional inquiries concerning how nuclear regulatory research is used. It summarizes the accomplishments of the Office of Nuclear Regulatory Research during FY 1992. A special emphasis on accomplishments in nuclear power plant aging research reflects recognition that a number of plants are entering the final portion of their original 40-year operating licenses and that, in addition to current aging effects, a focus on safety considerations for license renewal becomes timely. The primary purpose of performing regulatory research is to develop and provide the Commission and its staff with the technical bases for regulatory decisions on the safe operation of licensed nuclear reactors and facilities, to find unknown or unexpected safety problems, and to develop data and related information for the purpose of revising the Commission`s rules, ...
1993-05-01
NRC safety research in support of regulation, FY 1992
Energy Technology Data Exchange (ETDEWEB)
This report, the eighth in a series of annual reports, was prepared in response to congressional inquiries concerning how nuclear regulatory research is used. It summarizes the accomplishments of the Office of Nuclear Regulatory Research during FY 1992. A special emphasis on accomplishments in nuclear power plant aging research reflects recognition that a number of plants are entering the final portion of their original 40-year operating licenses and that, in addition to current aging effects, a focus on safety considerations for license renewal becomes timely. The primary purpose of performing regulatory research is to develop and provide the Commission and its staff with the technical bases for regulatory decisions on the safe operation of licensed nuclear reactors and facilities, to find unknown or unexpected safety problems, and to develop data and related information for the purpose of revising the ...
1993-05-01
British Library Electronic Table of Contents (United Kingdom)
Current studies in plants suggest that the content of the coenzyme NAD is variable and potentially important in determining cell fate. In cases that implicate NAD consumption, re-synthesis must occur to maintain dinucleotide pools. Despite information on the pathways involved in NAD synthesis in plants, the existence of a mitochondrial nicotinamide mononucleotide adenylyltransferase (NMNAT) activity which catalyses NAD synthesis from nicotinamide mononucleotide (NMN) and ATP has not been reported. To verify the latter assumed pathway, experiments with purified and bioenergetically active mitochondria prepared from tubers of Jerusalem artichoke (Helianthus tuberosus L.) were performed. To determine whether NAD biosynthesis might occur, NMN was added to Jerusalem artichoke mitochondria (JAM)...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
During the first few years of elevated atmospheric [CO2] treatment at the Nevada Desert FACE Facility, photosynthetic downregulation was observed in desert shrubs grown under elevated [CO2], especially under relatively wet environmental conditions. Nonetheless, those plants maintained increased A sat (photosynthetic performance at saturating light and treatment [CO2]) under wet conditions, but to a much lesser extent under dry conditions. To determine if plants continued to downregulate during long-term exposure to elevated [CO2], responses of photosynthesis to elevated [CO2] were examined in two dominant Mojave Desert shrubs, the evergreen Larrea tridentata and the drought-deciduous Ambrosia dumosa, during the eighth full growing season of elevated [CO2] treatment at the NDFF. A comprehen...
2011-01-01
Korea's experience and program on CANDU fuel R and D and fabrication
International Nuclear Information System (INIS)
In Korea, a manufacturing process for the fabrication of CANDU 37-element fuel bundles was successfully developed between 1981 and 1986. At Korea Atomic Energy Research Institute (KAERI), more than 20,000 fuel bundles were produced up to May 1992, for use in Wolsung-1 power reactor. At the time of the conference, about 15,000 of these fuel bundles had been irradiated in Wolsung-1, and almost all of them had performed well. From 1995, the commercial fuel production program will be transferred to Korea Nuclear Fuel Company, which is building a plant with a capacity of 400 tons of uranium per year. So-called CANFLEX fuel, more appropriate to advanced fuel cycles, is being developed jointly by AECL and KAERI. The paper includes a listing of the current status of the Republic of Korea's nuclear power plants, with planning projections up to the year 2006. 2 tabs.
1992-10-04
Human reliability analysis in Wolsung 2/3/4 nuclear power plants probabilistic safety assessment
Energy Technology Data Exchange (ETDEWEB)
The Level 1 probabilistic safety assessment (PSA) for Wolsung(WS) 2/3/4 nuclear power plant (NPPs) in design stage is performed using the methodologies being equivalent to PWR PSA. Accident sequence evaluation program (ASEP) human reliability analysis (HRA) procedure and technique for human error rate prediction (THERR) are used in HRA of WS 2/3/4 NPPs PSA. The= purpose of this paper is to introduce the procedure and methodology of HRA in WS 2/3/4 NPPs PSA. Also, this paper describes the interim results of importance analysis for human actions modeled in WS 2/3/4 PSA and the findings and recommendations of administrative control of secondary control area from the view of human factors. (Author) 10 refs., 2 tabs.
1997-05-01
Human reliability analysis in Wolsong 2/3/4 nuclear power plants probabilistic safety assessment
International Nuclear Information System (INIS)
The Level 1 probabilistic safety assessment (PSA) for Wolsong(WS) 2/3/4 nuclear power plant(NPPs) in design stage is performed using the methodologies being equivalent to PWR PSA. Accident sequence evaluation program (ASEF) human reliability analysis (HRA) procedure and technique for human error rate prediction (THERP) are used in HRA of WS 2/3/4 NPPs PSA. The purpose of this paper is to introduce the procedure and methodology of HRA in WS 2/3/4 NPPs PSA. Also, this paper describes the interim results of importance analysis for human actions modeled in WS 2/3/4 PSA and the findings and recommendations of administrative control of secondary control area from the view of human factors.
1997-05-01
British Library Electronic Table of Contents (United Kingdom)
The rational use of energy has become a priority for all industries in Brazil, mainly after the energy rationing in 2001. Methodologies to quantify and improve the performance of plants that consume and generate electricity and thermal energy are being used to reach this goal. Exergoeconomic analysis provides a complete diagnosis of a plant, both in exergetic and in monetary values. This study shows the methodology used to assess the power generation system of the Companhia Siderurgica Tubarao (CST). The current system is based on a regenerative Rankine cycle using two gases from steel production - blast furnace gas (BFG) and coke oven gas (COG) - to generate electric power and occasionally steam for the process. Use of the Theory of Exergetic Cost allowed determination of monetary and exe...
2009-01-01
Draft Regulatory Rule-making for On-line Maintenance of Nuclear Power Plants
International Nuclear Information System (INIS)
Internationally, on-line maintenance (OLM) of nuclear power plants under the operation is prevailed to enhance nuclear safety and economics. In recent years, Korea Hydro and Nuclear Power Co. Ltd. (KHNP) is eager to apply OLM. Ministry of Education, Science and Technology (MEST) has established the related technology development program as an item of 'Overall Planning on Nuclear Safety(2010-2014)' through acceptance to the request of KHNP in 2009. OLM is defined as maintenance that is performed with the main generator connected to the grid. In other words, it means a preventive maintenance to be implemented during the allowable outage time (AOT) with ignoring inoperability of safety-related equipment listed in the technical specifications. The Korea Institute of Nuclear Safety (KINS) is developing the assessment technology of safety concerns for OLM under the auspices of MEST. Draft regulatory rule-making for OLM is devised as a part of the ...
2010-10-01
Containment closure time following loss of cooling under shutdown conditions of YGN units 3 and 4
Energy Technology Data Exchange (ETDEWEB)
The YGN Units 3 and 4 plant conditions during shutdown operation were reviewed to identify the possible event scenarios following the loss of shutdown cooling. The thermal hydraulic analyses were performed for the five cases of RCS configurations under the worst event scenario, unavailable secondary cooling and no RCS inventory makeup, using the RELAP5/MOD3.2 code to investigate the plant behavior. From the analyses results, times to boil, times to core uncovery and times to core heat up were estimated to determine the containment closure time to prevent the uncontrolled release of fission products to atmosphere. These data provide useful information to the abnormal procedure to cope with the event. 6 refs., 7 figs., 2 tabs. (Author)
1998-12-31
Causes of denting. Volume 1. Summary report. Final report
This summary report outlines the work that was performed to gain a more complete understanding of denting corrosion of steam generators in PWRs. Background laboratory and plant data on denting were compiled, reviewed and correlated to determine how various exposure conditions affect denting. Two high-temperature chemistry analytical models were reviewed and evaluated by experimental simulation of impurity concentration in the heat transfer and isothermal capsule tests. Simulation of impurity concentration for three cooling waters (lake, river, and cooling tower) was evaluated. The effects of species concentration (Cu/sup + +/, Cl/sup -/, O/sub 2/, and H/sup +/), contaminant thresholds (established by isothermal and heat transfer tests), and heat flux as indicated by superheat on denting were examined. A discussion of several pertinent observations and conclusions drawn from these tasks (as they pertain to plant operation) ...
1984-05-01
Benefits and applications of modular hydroelectric pumped storage
International Nuclear Information System (INIS)
This paper reports on hydroelectric pumped storage which is the only proven and most efficient technology available for energy storage. It is used by utilities to provide peak and intermediate power and to optimize overall system performance. Because of increased environmental and regulatory constraints, few acceptable sites, long schedules, and huge financial commitments, large conventional pumped storage plants, are now virtually impossible to build. As an alternative, small modular pumped storage, with project sizes ranging from 25 MW to 200 MW, was created to overcome the difficulties of conventional projects. The modular approach involves standardizing the elements of a pumped storage plant by utilizing specialized siting techniques and optimizing design, equipment, and construction. Compared with conventional pumped storage, the modular design can reduce cost and expedite schedule; reduce environmental concerns and ...
1991-07-24
A neuro power system stabilizer based on adaptive control technique
Energy Technology Data Exchange (ETDEWEB)
A power system stabilizer based on GMV (Generalized Minimum Variance), one of the adaptive control techniques, is developed to enhance the dynamic performances of a power system using an Artificial Neural Network (ANN). The stabilizer consists of two parts. One part is Inverse Dynamics Neural Networks (IDNN), which is trained to identify the inverse dynamics of controlled plant and used as a one-step ahead controller, or inverse controller. The other part is Adaptive Reference Model (ARM), which prevents excessive controller output. The ARM produces the modified reference value by minimizing a cost function recursively on the assumption that the IDNN perfectly identifies the controlled plant. The IDNN is used in the minimization procedure to calculate the sensitivities. The proposed controller is simulated in a typical one-machine-infinite-bus power system to show its effectiveness to damp sustained low frequency ...
1996-12-31
Use of BWR/6 PRA to assess the effect of proposed new QA requirements
International Nuclear Information System (INIS)
The probabilistic risk assessment (PRA) of the General Electric BWR/6 Mark III standard plant has been used to assess the effect of proposed new quality assurance requirements on the off-site plant risk. This work was performed by General Electric Company under contract to the Electric Power Research Institute. First, the potential changes in the reliability of structures, systems and components were estimated. Then those changes that could affect the event tree and fault tree results were identified. Finally these changes were propagated through the probabilistic risk assessment fault trees and event trees to determine the effect upon off-site plant risk. The results show that applying quality assurance requirements, very nearly equal to those of 10CFR50, Appendix B (3), to nearly all nonsafety-related structures, systems, and components would have a negligible effect on off-site ...
1985-02-01
Energy Technology Data Exchange (ETDEWEB)
Hydrogen injection into the reactor water has been applied to many BWR power stations. Since hydrogen injected accelerates recombination of oxidant generated by water radiolysis, oxidant concentration, such as dissolved oxygen concentration in reactor water can be reduced. As the result of the reduction of oxidant concentration, Electrochemical Corrosion Potential (ECP) at the surface of structural material can be lowered. Lowered ECP moderates Stress Corrosion Cracking (SCC) sensitivity of structural materials, such as stainless steels. As usual, hydrogen injection system begins to work after the plant start-up is finished, when the condition of normal operation is established. Accordingly, Hydrogen Water Chemistry (HWC) does not cover all the period of plant operation. As far as SCC crack growth is considered, loss of HWC during plant start-up does not result in significant crack growth, because of duration of ...
2004-07-01
Energy Technology Data Exchange (ETDEWEB)
In order to serve for efficient energy utilization and environmental improvement in the Republic of Vietnam, a 'Model project to reduce electric power consumption at cement burning plant' has been implemented. This paper summarizes the achievements. This project is intended to add an advanced, matured and reliable electric power generation facility using cement waste heat to the existing cement plant in Vietnam to produce steam and generate power by utilizing the waste heat generated from the preheating process in the burning plant. The present project has performed the detailed designing on the piping, electric facilities and instrumentation based on the basic agreement on the project. Fabrication of the piping has been executed by the Vietnam side. Valves and electric devices were procured and transported, including those fabricated in the previous fiscal year. Technology guiding ...
2002-03-01
Insights from Guideline for Performance of Internal Flooding Probabilistic Risk Assessment (IFPRA)
Energy Technology Data Exchange (ETDEWEB)
An internal flooding (IF) risk assessment refers to the quantitative probabilistic safety assessment (PSA) treatment of flooding as a result of pipe and tank breaks inside the plants, as well as from other recognized flood sources. The industry consensus standard for Internal Events Probabilistic Risk Assessment (ASME-RA-Sb-2005) includes high-level and supporting technical requirements for developing internal flooding probabilistic risk assessment (IFPRA). This industry standard is endorsed in Regulatory Guide 1.200, Revision 1 as an acceptable approach for addressing the risk contribution from IF events for risk informed applications that require U.S. Nuclear Regulatory commission (NRC) approval. In 2006, EPRI published a draft report for IFPRA that addresses the requirements of the ASME PRA consensus standard and have made efforts to refine and update the final EPRI IFPRA guideline. Westinghouse has performed an IFPRA analysis for several ...
2009-10-15
Effectively managing nuclear risk through human performance improvement
International Nuclear Information System (INIS)
Full text: The US commercial nuclear industry has just completed an outstanding decade of plant performance. Safety levels and electric production are at unprecedented high levels and continue to exceed even high industry goals. Nuclear energy continues to keep the highest priority on performance improvement programs and highly trained/qualified people that maintain its record setting safety and reliability of operations. While the industry has maintained a consistently high level of performance, the advent of deregulation and the consolidation of NPP ownership, as well as the current climate of concern about both rising energy costs and availability of power, has raised the standard for nuclear energy's level of competitiveness in today's market place. The resulting challenge is how to more effectively manage risk and improve performance even further in a generally high ...
Wall thinning trend analyses for secondary side piping of Korean NPPs
International Nuclear Information System (INIS)
Since the mid-1990s, nuclear power plants in Korea have experienced wall thinning, leaks, and ruptures of secondary side piping caused by flow-accelerated corrosion (FAC). The pipe failures have increased as operating time progresses. In order to prevent the FAC-induced pipe failures and to develop an effective FAC management strategy, KEPRI and KOPEC have conducted a study for developing systematic FAC management technology for secondary side piping of all Korean nuclear power plants. As a part of the study, FAC analyses were performed using the CHECWORKS code. The analysis results were used to select components for inspection and to determine inspection intervals on each nuclear power plant. This paper describes the introduction of the FAC analysis method and the wall thinning trend analysis results by reactor type, system, and water treatment amine. This paper also represents the site application ...
2003-08-17
International Nuclear Information System (INIS)
Iron concentration control in feedwater is one of the most important subjects in water chemistry. Especially for the BWR plants without 100% flow volume of hollow fiber filter (HFF), rather high iron concentration in feedwater is one of the big issues as this causes relatively high radiation dose rate in drywell area. Cation exchange resins especially used in the plants with partial flow rate of HFF are expected to have the important role of capturing iron in feedwater. For this purpose, we have investigated the effective method for using iron absorption characteristics of cation exchange resin. The Cation-Over Layer method (COL) in condensate demineralizers (CD) effectively utilizes these characteristics. In order to demonstrate a performance of the cation overlay method, we had applied this method for three CD vessels at Fukushima Daiichi NPP Unit 3 for testing purpose. The result of this actual plant ...
2009-10-01
Status of the surry low power and shutdown PRA
International Nuclear Information System (INIS)
Traditionally, probabilistic risk analyses [PRA] of severe accidents in nuclear power plants have limited themselves to consideration of the set of initiating events occurring during full power operation. However, some analyses of accident initiators during low power, shutdown, and other modes of plant operation other than full power have been performed. These studies as well as the Chernobyl accident and recent operating experience at U.S. pressurized water reactors suggested that risks during low power and shutdown could be significant. As such, the analysis of the frequencies, consequences, and risks of these accidents was identified as one task in the Nuclear Regulatory Commission staff's study of the implications of the Chernobyl accident to U.S. commercial nuclear power plants. The surry PRA project is an ongoing high priority effort at BNL [Brookhaven National Laboratory] that is expected to ...
1990-10-01
International Nuclear Information System (INIS)
Nowadays the safety of Nuclear Power Plants is becoming more and more significant. Therefore consideration of severe accidents shall be included in both design and operating process of Nuclear Power Plants. In particular ground motion forms one of the important natural hazards. For structural analysis both linear-elastic and non-linear methods are specified by the engineering codes for earthquake resistance design. However, time history analysis is required for investigation of non-linear structural behaviour. Moreover, non-linearities are often caused by the presence of damage. This can be detected by means of structural health monitoring and subsequently system identification. In this paper the advantages of both dynamic time history analysis and damage detection by means of wavelet analysis are discussed. First, the non-linear behaviour of a frame structure due to an artificial earthquake motion is analyzed. A comparison to non-time history ...
2005-06-15
On appraising alternative power plant investment proposals. Pt. 1: The economic model
Energy Technology Data Exchange (ETDEWEB)
Combined energy plants operating on the Brayton-Rankine cycle have gained wide acceptance as the most efficient energy conversion system. The technology is well proven and numerous research activities are underway to develop it further past its present plateau of performance. In developed and emerging economies alike, the current situation in the global economic market has caused the liberalisation of the energy industry in some countries, and in others it is causing a rethink of economic and energy policies. A result is that electric utility companies that have enjoyed a monopoly in power generation and distribution are seeing this privilege being eroded. This is opening up opportunities for independent power production and, consequently, for gas/steam turbine plants because of the technical merits of the technology and its ability to fill the vacuum being created in the energy industry. An economic model has been ...
2000-12-01
Intra-day and regime-switching dynamics in electricity price formation
Energy Technology Data Exchange (ETDEWEB)
This paper analyses the complex, non-linear effects of spot price drivers in wholesale electricity markets: their intra-day dynamics and transient irregularities. The context is the UK market, after the reforms introduced in March 2001, analysed with an original set of price drivers reflecting economic, technical, strategic, risk, behavioural and market design effects. Models are estimated separately as daily time-series of the 48 half-hourly trading periods. All coefficients exhibit substantial intra-day variation, relating to the heterogeneity of operating plants and market design aspects. This reveals a market responding to economic fundamentals and plant operating properties, with learning and emergent financial characteristics, as well as some strategic manipulation of capacity, most effectively exercised by the more flexible plants. Using regime-switching parameters, the effects of capacity margin and inter-day ...
2008-07-15
Improving T D reliability. How pumped storage can boost network security
Energy Technology Data Exchange (ETDEWEB)
The key to improving transmission-network security is faster response to contingencies. Now a new breed of pumped-storage plant - designed for ultra-fast response - may soon provide a tool dispatchers can use to improve network security. This type of plant can also substantially increase the effective capacity of existing transmission lines and improve the performance of thermal generating units. The Mt. Hope Waterpower Project, planned for Rockaway Township, NJ, 35 miles west of New York City, lies strategically adjacent to major load centers at the eastern end of the PJM control area and near the interconnection point with the New York Power Pool (NYPP). This location also is in an area deficient in significant generating facilities. Maximum design capacity of the project is 2000 MW, provided by six reversible pump/turbines, each with a nominal 340-MW rating. The upper reservoir, with a surface area of only 60 acres, ...
1994-03-01
IGENPRO knowledge-based digital system for process transient diagnostics and management
Energy Technology Data Exchange (ETDEWEB)
Verification and validation issues have been perceived as important factors in the large scale deployment of knowledge-based digital systems for plant transient diagnostics and management. Research and development (R&D) is being performed on the IGENPRO package to resolve knowledge base issues. The IGENPRO approach is to structure the knowledge bases on generic thermal-hydraulic (T-H) first principles and not use the conventional event-basis structure. This allows for generic comprehensive knowledge, relatively small knowledge bases and above all the possibility of T-H system/plant independence. To demonstrate concept feasibility the knowledge structure has been implemented in the diagnostic module PRODIAG. Promising laboratory testing results have been obtained using data from the full scope Braidwood PWR operator training simulator. This knowledge structure is now being implemented in the transient management module ...
1997-12-31
Experiments with the HORUS-II test facility
Energy Technology Data Exchange (ETDEWEB)
Within the scope of the German reactor safety research the thermohydraulic computer code ATHLET which was developed for accident analyses of western nuclear power plants is more and more used for the accident analysis of VVER-plants particularly for VVER-440,V-213. The experiments with the HORUS-facilities and the analyses with the ATHLET-code have been realized at the Technical University Zittau/Goerlitz since 1991. The aim of the investigations was to improve and verify the condensation model particularly the correlations for the calculation of the heat transfer coefficients in the ATHLET-code for pure steam and steam-noncondensing gas mixtures in horizontal tubes. About 130 condensation experiments have been performed at the HORUS-II facility. The experiments have been carried out with pure steam as well as with noncondensing gas injections into the steam mass flow. The experimental simulations are characterized as ...
1997-12-31
Evaluation of structural integrity of crossover leg piping system with dynamic whip restraints
Energy Technology Data Exchange (ETDEWEB)
Interference between the crossover leg of the Reactor Coolant System(RCS) and the Pipe Whip Restraints(PWR) has brought a degradation issue of the integrity of the Reactor Coolant System in Westinghouse type Nuclear Power Plants(NPPs) of Korea. According to the gap inspection carried out during planned overhaul (year 2000), interference between the crossover leg and the PWR was found in each RCS loop. This plant has had the high vibration problem on the RC pump 'B'. The reason for the high vibration in the RC pump 'B' had been massively surveyed and it was found that the crossover leg of RCS contacted with the PWR in hot condition. Since the contact between the crossover leg and the PWR changes the dynamic characteristics of the piping system for the RCS, this is considered as one reason for the high vibration. And a possibility of overstress on the crossover leg due to the contact with the PWR should be ...
2001-07-01
Cogeneration in air separation cryogenic plants; Cogeracao em plantas criogenicas de separacao de ar
Energy Technology Data Exchange (ETDEWEB)
A thermal and economic study, carried on by using the first and second law of thermodynamics concepts demonstrated the economic feasibility of the cogeneration system, and proposed modifications to be done in the studied cryogenic plant, a typical T-240 NA MPL3 plant. The thermodynamic analysis showed that the second law efficiency of the processes could be improved, together with a 12% electric energy consumption reduction. Four cogeneration schemes were analyzed with both the first and second laws of thermodynamics and, then, the economic analysis was performed. Rankine, Brayton, Otto and Combined gas-steam basic cycles were used in this analysis.The combined gas-steam cycle was shown to be more economically feasible than others. Thermal and electric loads were well balanced, resulting in a higher second law efficiency. Although the initial investment for the modification was higher, the savings resulted to be higher, ...
2000-07-01
Catalytic oxidation of the unburnt fuel for the efficient production of electric energy
Energy Technology Data Exchange (ETDEWEB)
Modern combined cycle power plants with natural gas as the only fuel reach efficiencies of up to 58% for electric power generation. Nevertheless the reserves of natural gas are more limited compared to the reserves of coal. Therefore possibilities should be investigated to use coal for such plants also. One concept, that combines the use of coal in a combined cycle application with high efficiencies is examined in this paper. According to this concept the exhaust gas of the gas turbine (vitiated air) is the combustion air for the pulverised coal combustion, that takes place in the bottoming steam generator. Due to the low oxygen content of the vitiated air the burnout of the coal may be incomplete. In order to avoid the incomplete combustion of the coal and the resulting decrease of the efficiency of the plant and possible emission problems, a catalyst, that converts carbon monoxide and unburnt carbon to carbon dioxide ...
1995-12-31
CFD Analysis of a Dry Storage System for MACSTOR/KN-400
International Nuclear Information System (INIS)
There are four nuclear power plants in operation at Wolsong and, annually, more than 5,000 assemblies of spent nuclear fuels are released from each plant. Thus the concrete silo type dry storage system was constructed from '90. However, after 2006, another dry storage facility is required to accept the all amount of spent nuclear fuels from the plants. Instead of the concrete silo type, MACSTOR/KN-400 was developed to store the CANDU spent nuclear fuel more densely. In this study, computational fluid dynamics (CFD) analysis of the MACSTOR/KN-400 model was performed to confirm the thermal integrity of the facility, especially for the concrete structure, using the commercial CFD code, FLUENT. The MACSTOR/KN-400 which has Thermal Insulation Panel (TIP) and IAEA Re-verification Pipe (RVP) was modeled and analyzed in the view point of the thermal integrity of the concrete structure.
2007-10-01
Energy Technology Data Exchange (ETDEWEB)
During this project we experimentally evaluated the below-ground biomass and carbon allocation and partitioning of four different fast- and slow-growing families of loblolly pine located in Scotland County, NC, in an effort to increase the long-term performance of the crop. The trees were subjected to optimal nutrition and control since planting in 1993. Destructive harvests in 1998 and 2000 were used for whole?plant biomass estimates and to identify possible family differences in carbon acquisition (photosynthesis) and water use efficiency. At regular intervals throughout each year we sampled tissues for carbohydrate analyses to assess differences in whole-tree carbon storage. Mini rhizotron observation tubes were installed to monitor root system production and turnover. Stable isotope analysis was used to examine possible functional differences in water and nutrient acquisition of root systems between the various ...
2001-03-01
Analysis of complex systems using neural networks
Energy Technology Data Exchange (ETDEWEB)
The application of neural networks, alone or in conjunction with other advanced technologies (expert systems, fuzzy logic, and/or genetic algorithms), to some of the problems of complex engineering systems has the potential to enhance the safety, reliability, and operability of these systems. Typically, the measured variables from the systems are analog variables that must be sampled and normalized to expected peak values before they are introduced into neural networks. Often data must be processed to put it into a form more acceptable to the neural network (e.g., a fast Fourier transformation of the time-series data to produce a spectral plot of the data). Specific applications described include: (1) Diagnostics: State of the Plant (2) Hybrid System for Transient Identification, (3) Sensor Validation, (4) Plant-Wide Monitoring, (5) Monitoring of Performance and Efficiency, and (6) Analysis of Vibrations. Although specific ...
1992-01-01
Analysis of complex systems using neural networks
Energy Technology Data Exchange (ETDEWEB)
The application of neural networks, alone or in conjunction with other advanced technologies (expert systems, fuzzy logic, and/or genetic algorithms), to some of the problems of complex engineering systems has the potential to enhance the safety, reliability, and operability of these systems. Typically, the measured variables from the systems are analog variables that must be sampled and normalized to expected peak values before they are introduced into neural networks. Often data must be processed to put it into a form more acceptable to the neural network (e.g., a fast Fourier transformation of the time-series data to produce a spectral plot of the data). Specific applications described include: (1) Diagnostics: State of the Plant (2) Hybrid System for Transient Identification, (3) Sensor Validation, (4) Plant-Wide Monitoring, (5) Monitoring of Performance and Efficiency, and (6) Analysis of Vibrations. Although specific ...
1992-12-31
A procedure for batch separation of sup 14 C-hexose from sup 14 C-sucrose
Energy Technology Data Exchange (ETDEWEB)
This presentation describes a method for separating {sup 14}C-hexose from {sup 14}C-sucrose in extracts of plant tissue. Portions of ethanol extracts are treated with activated charcoal in microcentrifuge tubes. Aliquots are removed, ethanol evaporated and replaced with reaction mixture that phosphorylates hexose (HEPPS, K{sub 2}HPO{sub 4}, Mg(C{sub 2}H{sub 3}O{sub 2}){sub 2}, ovalbumen, Na{sub 2}ATP, yeast hexokinase). After a time course, the hexokinase reaction is stopped (slowed considerably) to minimize effects of contamination enzyme activities. The stopping agent used is lyxose, a nonphosphorylable analogue of glucose. The strong anionic charge of phosphate introduced through the hexokinase action results in binding (> 95%) of hexose-phosphate to anion-exchange resin. Sucrose remains unbound (> 95%) in solution. This batch ion-exchange is performed in microcentrifuge tubes to allow many samples to be processed simultaneously. ...
1991-05-01
Energy Technology Data Exchange (ETDEWEB)
The measuring series was performed from November 1991 through April 1992 in seven drinking-water conditioning plants of the Fichtel mountains area in the north-eastern part of Bavaria, and the results revealed as an annual average a dose of about 1 - 40 WLM. The area of interest is a drinking-water catchment area where the ground water and other water resources include waters particularly rich in radon content, which explains this relatively high dose range. This is why comprehensive, specific local and long-term mearurements were carried out in order to assess the occupational radiation dose in the drinking-water conditioning plants, taking as a model site the conditioning plant of the municipal utilities of Hof in Weissenstadt. These more specific measurements were performed by the Technical Inspectorates (TUeV) of Bavaria and Saxony and the isotope laboratory of Georg-August ...
1995-03-01
Vulnerability Analysis of Physical Protection System at Wolsung Nuclear Power Plant
Energy Technology Data Exchange (ETDEWEB)
The 9/11 event in the U.S.A has increased international terror possibilities against nuclear facilities including nuclear power plants(NPPs). It is necessary to assess the performance of an existing physical protection system(PPS) at nuclear facilities based on such malevolent acts. A PPS is a complex configuration of detection, delay, and response elements. Several methods are available to analyze a PPS and evaluate its effectiveness. Sandia National Laboratory(SNL) in the USA was developed a System Analysis of Vulnerability to Intrusion (SAVI) computer code for this purpose. It is powerful software for evaluating the effectiveness of PPS against outsider threats. This study presents the performance assessment of the PPS at Wolsung NPP using SAVI code. First, the site-specific Adversary Sequence Diagrams(ASDs) of the PPS is constructed. It helps to understand the functions of the existing PPS composed of physical areas and ...
2006-07-01
Vulnerability Analysis of Physical Protection System at Wolsung Nuclear Power Plant
International Nuclear Information System (INIS)
The 9/11 event in the U.S.A has increased international terror possibilities against nuclear facilities including nuclear power plants(NPPs). It is necessary to assess the performance of an existing physical protection system(PPS) at nuclear facilities based on such malevolent acts. A PPS is a complex configuration of detection, delay, and response elements. Several methods are available to analyze a PPS and evaluate its effectiveness. Sandia National Laboratory(SNL) in the USA was developed a System Analysis of Vulnerability to Intrusion (SAVI) computer code for this purpose. It is powerful software for evaluating the effectiveness of PPS against outsider threats. This study presents the performance assessment of the PPS at Wolsung NPP using SAVI code. First, the site-specific Adversary Sequence Diagrams(ASDs) of the PPS is constructed. It helps to understand the functions of the existing PPS composed of physical areas and ...
2006-05-25
The long operating cycle simplified boiling water reactor is a reactor concept that pursues both safety and the economy by employing a natural circulation reactor core without a refueling, a passive decay heat removal, and an integrated building for the reactor and turbine. Throughout the entire spectrum of the design basis accident, the reactor core is kept covered by the passive emergency core cooling system. The decay heat is removed by the conventional active low-pressure residual heat removal system. As for a postulated severe accident, the suppression pool water floods the lower part of the reactor pressure vessel (RPV) in the case when core damage occurs, and the in-vessel retention that keeps the melt inside the RPV is achieved by supplying the coolant. The containment adopts a parallel-double-steel-plate structure similar to a hull structure, which contains coolant between the inner and outer walls to absorb the heat transferred from the inside of the containment. ...
2003-07-15
Photovoltaic industry manufacturing technology. Final report
Energy Technology Data Exchange (ETDEWEB)
This report contains the results of the Photovoltaic (PV) Industry Manufacturing Technology Assessment performed by the Automation and Robotics Research Institute (ARRI) of the University of Texas at Arlington for the National Renewable Energy laboratory. ARRI surveyed eleven companies to determine their state-of-manufacturing in the areas of engineering design, operations management, manufacturing technology, equipment maintenance, quality management, and plant conditions. Interviews with company personnel and plant tours at each of the facilities were conducted and the information compiled. The report is divided into two main segments. The first part of the report presents how the industry as a whole conforms to ``World Class`` manufacturing practices. Conclusions are drawn from the results of a survey as to the areas that the PV industry can improve on to become more competitive in the industry and World Class. Appendix ...
1998-08-01
Energy Technology Data Exchange (ETDEWEB)
Waste form dissolution studies and preliminary performance analyses were carried out to contribute a part of the data needed for the selection of a waste form for the disposal of Savannah River Plant defense waste in a deep geologic repository. The first portion of this work provides descriptions of the chemical interactions between the waste form and the geologic environment. We reviewed critically the dissolution/leaching data for borosilicate glass and SYNROC. Both chemical kinetic and thermodynamic models were developed to describe the dissolution process of these candidate waste forms so as to establish a fundamental basis for interpretation of experimental data and to provide directions for future experiments. The complementary second portion of this work is an assessment of the impacts of alternate waste forms upon the consequences of disposal in various proposed geological media. Employing systems analysis methodology, we began to ...
1981-07-01
Ionic liquids for post combustion CO{sub 2} absorption
Energy Technology Data Exchange (ETDEWEB)
The use of ionic liquids for post combustion capture was discussed. Compared to other solvents, ionic liquids can be used in higher concentrations. Other advantages include the large variation in physical and chemical properties and the non measurable vapor pressure. In this study, 78 different ionic liquids were synthesized and the carbon dioxide absorption rate was measured. The most promising ionic liquids were produced and various tests were made to identify the most suitable absorption solvent. The vapor-liquid equilibrium curve was measured between 40 and 110 degrees C. Pilot plant tests with MEA and one selected ionic liquid test with 30 per cent MEA at the pilot plant at the EVNs Duernrohr Power Station in Lower Austria are running successfully with a capture performance of approximately 87 per cent. The experiments will provide a direct comparison of the energy demand and capture performance ...
2009-07-01
International Nuclear Information System (INIS)
A high-performance power system (HIPPS) is being developed. This system is a coal-fired, combined-cycle plant that will have an efficiency of at least 47 percent, based on the higher heating value of the fuel. The original emissions goal of the project was for NOx and SOx to each be below 0.15 lb/MMBtu. In the Phase 2 RFP this emissions goal was reduced to 0.06 lb/MMBtu. The ultimate goal of HIPPS is to have an all-coal-fueled system, but initial versions of the system are allowed up to 35 percent heat input from natural gas. Foster Wheeler Development Corporation is currently leading a team effort with AlliedSignal, Bechtel, Foster Wheeler Energy Corporation, Research-Cottrell, TRW and Westinghouse. Previous work on the project was also done by General Electric. The HIPPS plant will use a high-Temperature Advanced Furnace (HITAF) to achieve combined-cycle operation with coal as the primary fuel. The HITAF is an ...
1995-07-12
Development and validation of steam generator models for thermal performance monitoring
International Nuclear Information System (INIS)
The thermal performance monitoring and optimization system TEMPO is developed at the OECD Halden Reactor Project. The system supports staff of nuclear power plants in identification and correction of problems, which cause small decreases in plant efficiency but which may lead to significant economical losses. The system-wide physical model consists of mathematical description of individual components, such as the reactor, the pumps, the heat exchangers, or the turbines, etc. TEMPO code has recently been extended with new steam generator (SG) models. The present paper summarizes the thermal-hydraulic modelling aspects of the vertical and the horizontal SG. The heat balance equations and their solution are shown with the appropriate initial and boundary conditions. The method of the calculation of the pressure losses are also introduced. The vertical SG model is based on a U-tube structure and treated as a 1D flow channel. ...
2003-04-20
Comparison of advanced engines for parabolic dish solar thermal power plants
A paraboloidal dish solar thermal power plant produces electrical energy by a two-step conversion process. The collector subsystem is composed of a two-axis tracking paraboloidal concentrator and a cavity receiver. The concentrator focuses intercepted sunlight (direct, normal insolation) into a cavity receiver whose aperture encircles the focal point of the concentrator. At the internal wall of the receiver the electromagnetic radiation is converted to thermal energy. A heat engine/generator assembly, which is mounted directly behind th receiver, then converts the thermal energy captured by the receiver to electricity. Developmental activity has been concentrated on relatively small power modules which employ 11- to 12-m-diam dishes to generate nominal power levels of approximately 20 kW. A comparison of advanced heat engines for use on the dish power module is presented in terms of the performance potential of each engine as weighed against ...
1982-09-01
Combined cycle power plant with integrated low temperature heat (LOTHECO)
International Nuclear Information System (INIS)
The major driver to enhance the efficiency of the simple gas turbine cycle has been the increase in process conditions through advancements in materials and cooling methods. Thermodynamic cycle developments or cycle integration are among the possible ways to further enhance performance. The current paper presents the possibilities and advantages from the LOTHECO natural gas-fired combined cycle concept. In the LOTHECO cycle, low-temperature waste heat or solar heat is used for the evaporation of injected water droplets in the compressed air entering the gas turbine's combustion chamber. Following a description of this innovative cycle, its advantages are demonstrated by comparison between different gas turbine power generation systems for small and large-scale applications, including thermodynamic and economic analysis. A commercial gas turbine (ALSTOM GT10C) has been selected and computed with the heat mass balance program ENBIPRO. The results from the energy ...
2004-08-01
Energy Technology Data Exchange (ETDEWEB)
A number of binary geothermal cycles utilizing mixed hydrocarbon working fluids were analyzed with the overall objective of finding a working fluid which can produce low-cost electrical energy using a moderately-low temperature geothermal resource. Both boiling and supercritical shell-and-tube cycles were considered. The performance of a dual-boiling isobutane cycle supplied by a 280/sup 0/F hydrothermal resource (corresponding to the 5 MW pilot plant at the Raft River site in Idaho) was selected as a reference. To investigate the effect of resource temperature on the choice of working fluid, several analyses were conducted for a 360/sup 0/F hydrothermal resource, which is representative of the Heber resource in California. The hydrocarbon working fluids analyzed included methane, ethane, propane, isobutane, isopentane, hexane, heptane, and mixtures of those pure hydrocarbons. For comparison, two fluorocarbon refrigerants were also analyzed. ...
1981-02-01
International Nuclear Information System (INIS)
The CAMDU 6 reactor has an international reputation as one of the world's best performing and safe reactors. CANDU 6 reactors are consistently ranked in the world's top 10 for annual and lifetime performance. Six CANDU 6 units are currently in operation in four continents; in Quebec, New Brunswick, South Korea, Argentina and Romania. There are another two CANDU 6 units currently under construction at wolsong, in Korea which ore scheduled to go into service in 1998 and 1999 respectively. A second CANDU 6 unit is currently being considered for Romania. The construction of two CANDU 6 units at Qinshan, in China, is now underway. The performance of the four first-generation CANDU 6 plants, which have now been in service for 15 years, continue to show very good performance, with capacity factors on average since in-service of over 85%. The annual capacity factor of 10.21% during 1997 has ...
1998-03-23
The case of nuclear power: an economical analysis
Energy Technology Data Exchange (ETDEWEB)
In this paper an analysis will be performed to assess the economical competitiveness of Nuclear Power against other base load technologies. There are several plans to build more nuclear power plants in western countries; these plans are result among other things of the fossil fuel high prices and the concern for the global warming. France started the construction of one EPR at Flamanville in 2007 and at the end of 2008 there were 17 applications before NRC for construction and operation licenses (COL) to build as much as 26 new reactor units in USA, among the designs selected are the US-EPR, APWR, ESBWR, ABWR and AP1000. Currently, there is a lot of uncertainty about what is the overnight cost for a new generation III nuclear power plant and the vendors are not providing too much information. However, it is expected that under the new economy conditions the overnight cost will be between 2500 and 3500 USD/kW, the output ...
2009-06-15
Predictive maintenance plant assessment
Energy Technology Data Exchange (ETDEWEB)
Many electric power utilities are currently employing machine condition monitoring technologies as a means of reducing forced outages and controlling repair costs. These condition monitoring technologies are a set of {open_quotes}tools{close_quotes} to help maintenance and operations personnel identify and repair machinery problems before catastrophic failure occurs. In this way, the analysis of this data becomes a vital link in the daily operation of the plant. Machinery vibration analysis, machinery balancing and alignment, motor current testing, periodic thermography surveys, analysis of lubrication oil samples, performance monitoring, chemistry monitoring, ultrasonic leak detection surveys, and non-destructive inspections are some of the technologies available to perform this condition monitoring. However, even for a small or medium size plant, the sheer volume of data provided by applying all or ...
1996-07-01
Energy Technology Data Exchange (ETDEWEB)
The present project examined the operating characteristics and application possibilities of a new, compact combined heating and electricity generating unit with a thermal output of 14,5 kW and a generating capacity of 5,5 kW. Such a module was installed in a plant in Arlesheim (Canton of Basel-Country) and subject to performance measurements. The small heating and generating plant is designed for cyclic operation (without heat storage) and is very compact and low in cost. The heating and generating unit conforms to all Swiss regulations relating to electrical installations and air pollution control. The NO{sub x} emissions of the unit (400 mg/m{sup 3} in steady state operation) are above the limits of LRV 92 (80 mg/m{sup 3}), but the regulation does not apply for units in this power range. The electricity generation costs are approximately CHF 0.16/kWh. It therefore makes sense to install the module in regions with average ...
1995-12-01
Characteristics of U-tube assembly design for CANDU 6 type steam generators
Energy Technology Data Exchange (ETDEWEB)
Since the first operation of nuclear steam generator early 1960s, its performance requirements have been met but the steam generator problems have been met but the steam generator problems have been major cause of reducing the operational reliability, plant safety and availability. U-tube assembly of steam generator forms the primary system pressure boundary of the plant and have experienced several types of tube degradation problems. Tube failure and leakage resulting from the degradation will cause radioactive contamination of secondary system by the primary coolant, and this may lead to unplanned plant outages and costly repair operations such as tube plugging or steam generator replacement. For the case of steam generators for heavy water reactors, e.g. Wolsong 2, 3, and 4 NPP, a high cost of heavy water will be imposed additionally. During the plant operation, steam generator ...
1996-06-01
Steam generator tube performance: experience with water-cooled nuclear power reactors during 1979
International Nuclear Information System (INIS)
The performance of steam generator tubes in water-cooled nuclear power reactors has been reviewed for 1979. Tube failures occurred at 38 of the 93 reactors surveyed. Causes of these failures and procedures designed to deal with them are described. The defect rate was twice that in 1978 but still lower than the two previous years. Methods being employed to detect defects include increasing use of multifrequency eddy-current testing and a trend to full-length inspection of all tubes. To reduce the incidence of tube failures by corrosion, plant operators are turning to full-flow condensate demineralization and more leak-resistant condenser tubes. (author).
1994-10-18
International Nuclear Information System (INIS)
Liquid radioactive waste treatment method of using evaporator was widely used from Kori 1 to Uljin 3 and 4, but a liquid radioactive waste treatment equipment that uses an ion exchange method instead of an evaporator was adopted aiming to minimize amount of radioactive waste and radiation exposure. However, the same equipment was introduced and applied for the first time in Korea and had experienced difficulties in securing credibility for the equipment and handling of liquid radioactive waste with inadequate data about performance and experience in operation and maintenance. In this study, examination, application and effect analysis was performed on the optimization measure for handling liquid radioactive waste of Yonggwang Nuclear Power Unit 5 and 6(YGN 5 and 6) that applies an ion exchange method
2010-10-01
Flue-gas desulfurization inspection and performance evaluation. Manual
Energy Technology Data Exchange (ETDEWEB)
The intent of this manual is to provide inspectors from Federal and state environmental agencies with information regarding the problems that plague lime/limestone slurry flue-gas desulfurization (FGD) systems that will aid them in their inspections and performance evaluations of these systems with respect to compliance with the emission standards that have evolved since the passage of the 1970 Clean Air Act. A unique feature of the manual is its structure as a tool, or working document, which will accompany the inspector on each plant inspection. Thus, the document is presented in user friendly fashion and tailored to provide practical information for its intended use--to assist in the systematic inspection of an FGD system to determine present and future compliance status. The approach entails the use of nomographs, checklists, matrices, simplified diagrams, cross-referencing, and indexing of textual information, and the presentation of ...
1985-10-01
FFTF [Fast Flux Test Facility] reactor shutdown system reliability reevaluation
International Nuclear Information System (INIS)
The reliability analysis of the Fast Flux Test Facility reactor shutdown system was reevaluated. Failure information based on five years of plant operating experience was used to verify original reliability numbers or to establish new ones. Also, system modifications made subsequent to performance of the original analysis were incorporated into the reevaluation. Reliability calculations and sensitivity analyses were performed using a commercially available spreadsheet on a personal computer. The spreadsheet was configured so that future failures could be tracked and compared with expected failures. A number of recommendations resulted from the reevaluation including both increased and decreased surveillance intervals. All recommendations were based on meeting or exceeding existing reliability goals. Considerable cost savings will be incurred upon implementation of the recommendations.
FFTF (Fast Flux Test Facility) reactor shutdown system reliability reevaluation
Energy Technology Data Exchange (ETDEWEB)
The reliability analysis of the Fast Flux Test Facility reactor shutdown system was reevaluated. Failure information based on five years of plant operating experience was used to verify original reliability numbers or to establish new ones. Also, system modifications made subsequent to performance of the original analysis were incorporated into the reevaluation. Reliability calculations and sensitivity analyses were performed using a commercially available spreadsheet on a personal computer. The spreadsheet was configured so that future failures could be tracked and compared with expected failures. A number of recommendations resulted from the reevaluation including both increased and decreased surveillance intervals. All recommendations were based on meeting or exceeding existing reliability goals. Considerable cost savings will be incurred upon implementation of the recommendations.
1986-07-01
Experimental and analytical studies of pipe whip tests under PWR LOCA conditions
Energy Technology Data Exchange (ETDEWEB)
A series of pipe rupture tests has been performed at JAERI to demonstrate the safety of primary coolant circuits in the event of pipe rupture in nuclear power plants. Pipe whip tests and jet discharge tests have been conducted under BWR and PWR loss-of-coolant accident (LOCA) conditions. The present paper describes the experimental and analytical results of the pipe whip tests performed under PWR LOCA conditions using 4, 6 and 8-inch test pipes. The tests were carried out at an initial pressure and temperature of 15.7 MPa and 325/sup 0/C, respectively. Moreover, a dynamic analysis of pipe whip tests was carried out using the general purpose finite element programm ADINA.
1987-09-01
Common-Cause Failure Analysis for Reactor Protection System Reliability Studies
Energy Technology Data Exchange (ETDEWEB)
Analyses were performed of the safety-related performance of the reactor protection system (RPS) at U.S. Westinghouse and General Electric commercial reactors during the period 1984 through 1995. RPS operational data from these reactors were collected from the Nuclear Plant Reliability Data System (NPRDS) and Licensee Event Reports (LER). The common-cause failure (CCF) modeling in the fault trees developed for these studies and the analysis and use of common-cause failure data were sophisticated, state-of-the-art efforts. The overall CCF effort helped to test and expand the limits of the U.S. Nuclear Regulatory Commission's CCF methodology.
1999-08-01
CFD analysis and overheating control of a turbine
Energy Technology Data Exchange (ETDEWEB)
The thermal analysis of a turbine stack discharging exhaust gases to the atmosphere is presented. The examined turbine stack belongs to a gas lift plant for oil extraction located in the Gulf area. The analysis has been performed because an overheating of the anchor flange/bolts and of the concrete foundation occurred and caused small cracks in the upper layer of the foundation. A qualitative thermal analysis of the stack has pointed out that the main cause of the overheating was the thermal radiation in the air-filled region underneath the stack bottom plate. Detailed calculations performed by using a CFD code (Fluent ver. 6.0.12), cross-checked with measurements taken from site, have shown that a significant reduction of the heat flux to the foundation could be obtained by filling the above mentioned air region with an insulating material. The benefits of this solution are prevailing over those achievable with the ...
2004-11-01
Energy Technology Data Exchange (ETDEWEB)
As part of the EPRI Motor-Operated Valve (MOV) Performance Prediction Methodology, a System Flow Model (SFM) has been developed to determine the differential pressure (DP) across MOVs as they are stroked in typical power plant systems. Input to the SFM includes valve flow characteristics (such as flow coefficient) and system characteristics (such as pump head/flow curve). The primary output is differential pressure across the valve at each stroke position. The SFM was validated by comparison with test data from the EPRI Flow Loop Test Program. In this study, we calculated DP using SFM and performed DP test for four MOVs. Compared between calculated DP and test DP of four MOV, respectively good agreements are found. (author). 6 refs., 9 figs., 1 tab.
1999-11-01
Energy Technology Data Exchange (ETDEWEB)
A method for product analysis that eliminates a problematic step in the radiometric sucrose-phosphate synthase assay is described. The method uses chromatography on a boronate-derivatized high-performance liquid chromatography column to separate the labeled product, (14C)sucrose phosphate, from unreacted uridine 5{prime}-diphosphate-(14C)glucose (UDP-Glc). Direct separation of these compounds eliminates the need for treatment of the reaction mixtures with alkaline phosphatase, thereby avoiding the problem of high background caused by contaminating phosphodiesterase activity in alkaline phosphatase preparations. The method presented in this paper can be applied to many UDP-Glc requiring enzymes; here the authors show its use for determining the activities of sucrose-phosphate synthase, sucrose synthase, and uridine diphosphate-glucose pyrophosphorylase in plant extracts.
1991-05-01
Use of multipurpose trees in hill farming systems in western Nepal
Energy Technology Data Exchange (ETDEWEB)
A study of two villages identified 55 woody perennial species that are maintained in contour strips across slopes and around fields in a subsistence farming system. These trees and shrubs produced fodder and firewood and reduced erosion hazards, allowing crop production on very steep slopes where it would otherwise be very difficult. Data on basic farm management, production of crops, etc. are discussed. The performance of the system is assessed and its strengths and weaknesses highlighted. It is suggested that several locally available medicinal plants could be incorporated into the system.
1984-01-01
Risk assessment for the SNR-300 reactor. Earthquake hazard emanating from reactor component failure
International Nuclear Information System (INIS)
The risk analysis was carried out in consideration of conditions prevailing at the Kalkar site analogous to the investigations in phase A of DRS (German Reactor Study). Earthquake design loads include the probabilities of upper deviations of the site intensities to be expected. The calculations of dynamic loads for select buildings are made using models and computational methods. Component analyses were performed analogous to DRS for the supports of large components, supports of the roof construction of the reactor building taking into account support reserves due to plastic work capacity, wall disks in steam generator buildings and switchboard plant buildings. (DG).
Product yield and hydrogen consumption selectivity tests for coal liquefaction catalyst development
A method for analyzing the experimental results of coal liquefaction reactions which is applicable to a number of aspects of coal liquefaction research and process control, including rapid selectivity and performance screening for catalysts; correlation of laboratory results with process parameters; and optimization of product yield with plant process conditions is described here. Ternary diagrams of product/by-product distributions for the coal liquefaction using Co/Mo catalysts combined with a hyperbolic relationship for the conversion of various hydrocarbon fractions can be used for catalyst screening. A hydrogen consumption diagram used to provide a more significant selectivity test than the hyperbolic correlation is also included. (BLM)
1981-01-01
This workshop covered the latest practical engineering and operational management applications and techniques that have been found to enhance operational costs, reliability, and flexibility, with topics such as establishing the optimal refrigeration design cycle and operating design points; utility management; manpower scheduling; plant control philosophy and automation; short and long term maintenance scheduling; refrigerant loss detection and control; system contamination; component reliability; and equipment technical performance issues.
2006-11-10
Neural network for prediction of superheater fireside corrosion
Energy Technology Data Exchange (ETDEWEB)
Superheater corrosion causes vast annual losses to the power companies. If the corrosion could be reliably predicted, new power plants could be designed accordingly, and knowledge of fuel selection and determination of process conditions could be utilized to minimize superheater corrosion. If relations between inputs and the output are poorly known, conventional models depending on corrosion theories will fail. A prediction model based on a neural network is capable of learning from errors and improving its performance as the amount of data increases. The neural network developed during this study predicts superheater corrosion with 80 % accuracy at early stage of the project. (orig.) 10 refs.
1998-12-31
Making resource recovery economical
Energy Technology Data Exchange (ETDEWEB)
Four major reasons why municipal resource recovery operations are uneconomical are analyzed. These reasons are: alternative municipal waste disposal methods are artificially underpriced when the costs of meeting modern environmental standards are considered; high capital costs related to the procurement of resource recovery systems and the marketing of recovered resources; uncertainties associated with the costs and performance of resource recovery technologies; and construction and operating risks of municipal waste resource recovery systems. If resource recovery is to become economical, purchasers of plants must develop innovative process designs and equipment and formulate new operating and maintenance procedures. (1 photo)
1980-01-01
Energy Technology Data Exchange (ETDEWEB)
The conceptual design, parametric analysis, cost and performance analysis, and commercial assessment of a 100-MWe line-focus solar central receiver power plant are reported. This volume contains the appendices: (a) methods of determination of molten salt heat-transfer coefficients and tube-wall temperatures, (b) inputs for STEAEC programs, (c) description of system analysis computer program, (d) receiver analysis program, and (e) heliostat production plan and design methodology. (WHK)
1980-04-01
Energy Technology Data Exchange (ETDEWEB)
Thermal striping is identified as one of the causes of thermal fatigue failure in nuclear power plants. Numerical studies of thermal striping require three-dimensional, unsteady turbulent modeling that resolves both large and small-scale turbulent motions. Benchmark studies were carried out using the LES turbulence model solved by the commercial CFD code FLUENT. Two types of mixing tee configurations were modeled to evaluate the performance of the CFD code. The simulation results presented in normalized average temperature and normalized fluctuating temperatures are in good agreement with measurements.
2006-02-15
High capacity heavy media processing
Energy Technology Data Exchange (ETDEWEB)
Pittston Coal Company recognized the potential economic benefit of improving process efficiency with increased capacity at it`s U.K. No. 1 Coal Preparation Plant. Accordingly, extensive research, both domestically and internationally, was conducted to select the appropriate technologies to achieve the desired circuit in the most cost effective manner while, at the same time, sacrificing neither structural integrity nor process performance. Large diameter heavy media cyclone technology was combined with highly efficient banana type screens and improved high intensity magnetic separators to create a coordinated process circuit that provided high efficiency at very high capacities in an economically attractive package.
1996-12-31
GC-MS investigation and toxicological evaluation of alkaloids from Leptadenia pyrotechnica
British Library Electronic Table of Contents (United Kingdom)
GC-MS analysis of isolated alkaloids from aerial parts of Leptadenia pyrotechnica (Forsk.) Decne (Asclepiadaceae) was performed. Twenty-four alkaloids and six simple amines were detected for the first time in this plant. Almost all of the alkaloids belonged to pyridine, pyrrole, pyrazine, and indole types. The acute LC50 of the total alkaloids and alcohol extracts estimated by means of brine shrimp toxicity test were 63.09 and 11.89 ppm, respectively. The antitumor activities of these extracts, using potato disc screen, showed good activity represented by -33.6% and -49.3%, respectively.
2009-01-01
Fourth international seminar on horizontal steam generators
Energy Technology Data Exchange (ETDEWEB)
The general objective of the International Seminars of Horizontal Steam Generator Modelling has been the improvement in understanding of realistic thermal hydraulic behaviour of the generators when performing safety analyses for VVER reactors. The main topics presented in the fourth seminar were: thermal hydraulic experiments and analyses, primary collector integrity, feedwater distributor replacement, management of primary-to-secondary leakage accidents and new developments in the VVER safety technology. The number of participants, representing designers and manufacturers of the horizontal steam generators, plant operators, engineering companies, research organizations, universities and regulatory authorities, was 70 from 10 countries.
1997-12-31
Development of regulatory techniques for operational performance evaluation of nuclear power plants
Energy Technology Data Exchange (ETDEWEB)
In this study, the state-of-the art for estimating LERF is considered for the regulatory risk-informed decisions. The consideration is mainly focused on (1) the relationship between Level 2 PSA and LERF evaluation methodology, (2) the standard requirements in terms of modeling preparation and the acceptance criteria based on the application capability II of ASME PRA standard, and (3) some pending issues for developing and proposing a simplified LERF model. This study is preliminarily presented and will be updated for establishing detailed evaluation scheme of extended MPAS (multi-purpose probabilistic analysis of safety) model and preparing the technical basis.
2006-01-15
Conditional risk assessment of SNR 300 in case of an unprotected loss of flow accident
International Nuclear Information System (INIS)
This paper gives a summary of a risk study assuming unprotected loss of flow (ULOF) in the SNR 300. This study was initiated in 1979/80 by the Karlsruhe Nuclear Research Center and performed in close cooperation with Science Applications Inc., Palo Alto, USA, and Interatom Company. Part of the results also was integrated in the 'Risk Related Analysis for the SNR 300' carried out by the Gesellschaft fuer Reactorsicherheit. The character of the study described here is similar to other risk studies like the Reactor Safety Study and the German Risk Study for Nuclear Power Plants. The objectives and the methodology of the analyses are described and its results are discussed. (orig./RW).
Condensing curves for a number of mixed-hydrocarbon working fluids
Energy Technology Data Exchange (ETDEWEB)
Condensing curves are presented for a number of two-component mixed hydrocarbon working fluids which are potentially usable in binary geothermal cycles. Performance of geothermal thermodynamic cycles incorporating these fluids has been evaluated under separate cover; two figures summarizing the results of those evaluations have been included here for continuity. The purpose of this report is: first, to document the condensing curves which were used in the mixed fluid cycle analyses, and second, to provide background useful in the preliminary evaluation of heat rejection systems for advanced geothermal electric power plants utilizing mixed hydrocarbon working fluids. Some concluding remarks are presented.
1981-07-01
Energy Technology Data Exchange (ETDEWEB)
A small scale biomass metal contacting experiment was performed to screen the optimal plant species for biosorption and bioaccumulation of cadmium, zinc, nickel, lead, and copper. Experiments were also conducted to test the ability of the biomass to lower the metal concentrations below the US Environmental Protection Agency surface water discharge criteria. The minimum residual concentration was 0.1 mg/L for zinc, 0.004 mg/L for lead, and about 0.01 mg/L for cadmium, nickel, and lead. Results indicate that water milfoil can be used for bioremoval of metals.
1995-12-31
Energy Technology Data Exchange (ETDEWEB)
The thermal-hydraulic tests for a horizontal steam generator of a next-generation PWR (New PWR-21) were performed. The purpose of these tests is to understand the thermal-hydraulic behavior in the secondary side of horizontal steam generator during the plant normal operation. A test was carried out with cross section slice model simulated the straight tube region. In this paper, the results of the test is reported, and the effect of the horizontal steam generator internals on the thermal-hydraulic behavior of the secondary side and the circulation characteristics of the secondary side are discussed. (author)
1996-12-31
International Nuclear Information System (INIS)
The thermal-hydraulic tests for a horizontal steam generator of a next-generation PWR (New PWR-21) were performed. The purpose of these tests is to understand the thermal-hydraulic behavior in the secondary side of horizontal steam generator during the plant normal operation. A test was carried out with cross section slice model simulated the straight tube region. In this paper, the results of the test is reported, and the effect of the horizontal steam generator internals on the thermal-hydraulic behavior of the secondary side and the circulation characteristics of the secondary side are discussed. (author).
1996-10-15
2005 clean coal and power conference. Conference proceedings
Energy Technology Data Exchange (ETDEWEB)
The theme of the conference was 'The paradox: today's coal technologies versus tomorrow's promise'. The sessions covered: today's technologies, tomorrow's potential; economic stability; energy security; transition to sustainable energy future; new coal power technologies leading to zero emission coal; existing power plants - improved performance through use of new technology; and carbon capture and storage R & D - challenges and opportunities. Some of the papers only consist of the viewgraphs/overheads.
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
The integrated-gasification combined-cycle (IGCC) process is an emerging technology that utilizes coal for power generation and production of chemical feedstocks. However, the process generates large amounts of solid waste, consisting of vitrified ash (slag) and some unconverted carbon. In previous projects, Praxis investigated the utilization of {open_quotes}as-generated{close_quotes} slags for a wide variety of applications in road construction, cement and concrete production, agricultural applications, and as a landfill material. From these studies, we found that it would be extremely difficult for {open_quotes}as-generated{close_quotes} slag to find large-scale acceptance in the marketplace even at no cost because the materials it could replace were abundantly available at very low cost. It was further determined that the unconverted carbon, or char, in the slag is detrimental to its utilization as sand or fine aggregate. It became apparent that a more ...
1998-12-31
Improvement of fuel performance in the Wolsung Nuclear Power Plant
International Nuclear Information System (INIS)
From the start of commercial operation in 1983 until the end of 1985, the Wolsung Nuclear Power Plant operated for about 800 effective full power days (EFPDs). During this relatively short operational period it experienced various problems but achieved high reliability in operation. Wolsung recorded economical fuel utilization, particularly in 1985, together with a 94.4% plant capacity factor; it also showed successful in-pile test results as part of a fuel localization project. The actual fuelling rate was 16.3 bundles per EFPD in 1985, i.e. a saving of about 11% compared with the design fuelling rate of 18.2 bundles per EFPD. Better fuel performance was achieved because minimum excess reactivity was maintained in the core, characteristics unique to the core were found and the spatial flux distribution was controlled. The average discharge fuel burnup in 1985 was 6993 MW#centre dot#d/t U, which was 8.5% more than the ...
1986-09-15
A Virtual Engineering Framework for Simulating Advanced Power System
Energy Technology Data Exchange (ETDEWEB)
In this report is described the work effort performed to provide NETL with VE-Suite based Virtual Engineering software and enhanced equipment models to support NETL's Advanced Process Engineering Co-simulation (APECS) framework for advanced power generation systems. Enhancements to the software framework facilitated an important link between APECS and the virtual engineering capabilities provided by VE-Suite (e.g., equipment and process visualization, information assimilation). Model enhancements focused on improving predictions for the performance of entrained flow coal gasifiers and important auxiliary equipment (e.g., Air Separation Units) used in coal gasification systems. In addition, a Reduced Order Model generation tool and software to provide a coupling between APECS/AspenPlus and the GE GateCycle simulation system were developed. CAPE-Open model interfaces were employed where needed. The improved simulation capability is ...
2008-06-18
International Nuclear Information System (INIS)
The IAEA Code of Practice on Quality Assurance for Safety in Nuclear Power Plants and the corresponding Safety Guides are reviewed and compared with quality assurance (QA) practices in the IAEA Member States. The QA requirements stipulated by the Code place on the nuclear power plant owner the responsibility to establish an overall QA programme for the plant. In selecting the QA programme level for specific activities, the Code allows of a flexible approach but does not specify gradation in programme requirements. The Code is placing the burden of quality-achieving and quality-assuring functions on the task-performing organizations, namely the designers, manufacturers, constructors and plant operators. The plant owner provides for the management of the overall QA programme, surveillance of activities and verifications of the effectiveness of the constituent ...
Energy Technology Data Exchange (ETDEWEB)
Rice plants at different seed-developing stages were exposed to HTO vapor in an exposure box for 1 h during daytime and nighttime to investigate the levels of tissue free water {sup 3}H (TFWT) and organically bound {sup 3}H (OBT) in different plant parts. In the daytime experiment, TFWT concentrations in leaves at the end of exposure (h{sub 0}) were around 100% of the 1 hour mean HTO concentrations in air moisture whereas in the nighttime experiment, they were as low as 30{approx}40% of the air concentration. TFWT concentrations in both experiments decreased very rapidly in the beginning but much more slowly later and those at harvest were hundreds to hundred thousands times lower than those at h{sub 0}. OBT concentrations varied with time in different manners depending on plant parts and exposure times and differed between at h{sub 0} and at harvest by factors of less than 10 on the whole. Even during nighttime exposures, ...
2003-03-15
Energy Technology Data Exchange (ETDEWEB)
Investigations and studies are conducted seeking for a CO2 fixation method improved by utilizing the photosynthesizing function of higher vegetation. Details of higher vegetation genes are being disclosed thanks to the rapid progress of studies making use of molecular biological techniques, and the application of the genetic mechanism to scientific and technological fields is becoming increasingly feasible. In particular, the role of the CO2 fixation enzyme RuBisCO has been elucidated almost completely. It has been learned that, in terms of photosynthesizing capability, the C{sub 4} plants (corn etc.) are 2-3 times higher than the C{sub 3} plants (rice, wheat, etc.), and 5-10 times higher than the CAM plants (cactuses etc.). Studies are also under way about the rice genome so that a photosynthesizing capability so high as that of the C{sub 4} plants may be endowed the rice plant. ...
1999-03-01
Risk assessment of severe accident-induced steam generator tube rupture
Energy Technology Data Exchange (ETDEWEB)
This report describes the basis, results, and related risk implications of an analysis performed by an ad hoc working group of the U.S. Nuclear Regulatory Commission (NRC) to assess the containment bypass potential attributable to steam generator tube rupture (SGTR) induced by severe accident conditions. The SGTR Severe Accident Working Group, comprised of staff members from the NRC`s Offices of Nuclear Reactor Regulation (NRR) and Nuclear Regulatory Research (RES), undertook the analysis beginning in December 1995 to support a proposed steam generator integrity rule. The work drew upon previous risk and thermal-hydraulic analyses of core damage sequences, with a focus on the Surry plant as a representative example. This analysis yielded new results, however, derived by predicting thermal-hydraulic conditions of selected severe accident scenarios using the SCDAP/RELAP5 computer code, flawed tube failure modeling, and tube failure probability ...
1998-03-01
Development of next-generation light water reactor in Japan
International Nuclear Information System (INIS)
In Japan, the development of next-generation Light Water Reactor has been launched since April 2008. The development program will be completed in 2015. The purpose of development is to cope with the replacement for existing nuclear power plants after 2030 in Japan and the expanding demand for nuclear power in the world; 'Nuclear Renaissance.' The reactor also aims to be global standard at around 2030. The requirements for global standard and domestic users have been investigated through the feasibility study of past 2 years, 2006-2007, and six innovative features or 'Core-Concepts' were established as follows. A) Reactor core system with uranium enrichment above 5% for significant decrease of spent fuel discharge and prominent higher availability B) Long-life materials and innovative water chemistry technologies for 80 years plant lifetime and significant reduction of occupational dose C) Seismic isolation technologies to standardize ...
2009-10-27
Picture tour of Sasol II coal liquefaction plant
Energy Technology Data Exchange (ETDEWEB)
This is a collection of photographs of the plant which is now almost completed.
1980-03-01
Human Issues in Manufacturing Technology
... qualified manufacturing employees. David Lichtinger, plant manager for Lord Corporation's aerospace products plant in ...
1992-09-01
Applied and fundamental aspects of plant cell, tissue, and organ culture
Applied and fundamental aspects of plant cell, tissue, and organ culture
1977-01-01
Indicators of safety culture - selection and utilization of leading safety performance indicators
International Nuclear Information System (INIS)
Safety indicators play a role in providing information on organizational performance, motivating people to work on safety and increasing organizational potential for safety. The aim of this report is to provide an overview on leading safety indicators in the domain of nuclear safety. The report explains the distinction between lead and lag indicators and proposes a framework of three types of safety performance indicators - feedback, monitor and drive indicators. Finally the report provides guidance for nuclear energy organizations for selecting and interpreting safety indicators. It proposes the use of safety culture as a leading safety performance indicator and offers an example list of potential indicators in all three categories. The report concludes that monitor and drive indicators are so called lead indicators. Drive indicators are chosen priority areas of organizational safety activity. They are based on the ...
2010-05-01
Transient performance of FFTF [Fast Flux Test Facility] reference fuel
International Nuclear Information System (INIS)
Fourteen irradiated Fast Flux Test Facility (FFTF) fuel pins were subjected to representative overpower transients in six flowing sodium loop experiments conducted in the TREAT reactor. The transient tests were extended to substantial overpower levels well beyond protected levels, with some tests intentionally run to failure to identify failure thresholds and characteristics. Test variables included transient ramp rate (5, 50, and 100 cents/s) and burnup (2 to 58 MWd/kg). Performance limits and failure characteristics were identified, and cladding strain and fuel melting data were obtained for development and verification of transient analysis codes. The test results demonstrated that FFTF Reference fuel pins are capable of surviving overpower levels well beyond the FFTF secondary Plant Protection System (PPS) trip limit of 1.25 times normal rated power. Based on analytical evaluations to interpolate and extrapolate test results to the full ...
1986-09-07
The influence of salt aerosol on alpha radiation detection by WIPP continuous air monitors
Energy Technology Data Exchange (ETDEWEB)
Alpha continuous air monitors (CAMs) will be used at the Waste Isolation Pilot Plant (WIPP) to measure airborne transuranic radioactivity that might be present in air exhaust or in work-place areas. WIPP CAMs are important to health and safety because they are used to alert workers to airborne radioactivity, to actuate air-effluent filtration systems, and to detect airborne radioactivity so that the radioactivity can be confined in a limited area. In 1993, the Environmental Evaluation Group (EEG) reported that CAM operational performance was affected by salt aerosol, and subsequently, the WIPP CAM design and usage were modified. In this report, operational data and current theories on aerosol collection were reviewed to determine CAM quantitative performance limitations. Since 1993, the overall CAM performance appears to have improved, but anomalous alpha spectra are present when sampling-filter salt ...
1996-01-01
Product yield and hydrogen consumption selectivity tests for coal-liquefaction-catalyst development
Because hydrogenation of coal to liquid products (oils) is accompanied by distributions of complex by-product mixtures (IOM, preasphaltenes, asphaltenes and gases) which change as a function of reaction variables (time, temperature and pressure) and reactor configuration, the determination of selectivity relationships for coal liquefaction catalysts has been a difficult and time-consuming task involving numerous experiments to adequately describe catalyst performance over a range of conditions. This paper describes a method for analyzing the experimental results of coal liquefaction reactions which may be applied to a number of aspects of coal liquefaction research and process control, including: rapid selectivity and performance screening for catalysts; correlation of laboratory results with process parameters; and optimization of product yield for plant process conditions. Catalyst selectivity and ...
1981-01-01
BWR containment vessel drywell head bolt de-tensioning during noble metal chemical application
Energy Technology Data Exchange (ETDEWEB)
Implementation of Noble Metal Chemical Application (NMCA) in a Boiling Water Reactor (BWR) requires injection of a noble metal compound while the reactor is idle at hot shutdown conditions. In order to minimize outage time, utilities are very pro-actively finding ways to reduce the number of critical path tasks. One of these tasks is to remove some containment vessel drywell head bolts during the NMCA idle time. This, thereby, saves the utilities outage time, or they can perform other tasks as desired. Using design basis conditions and state-of-the-art analytical techniques, detailed finite element stress analyses of the closure region are performed. Two acceptance criteria are evaluated. The first is that contained within Section III of the ASME Code for allowable stresses. The second relates to leak tightness, i.e., with bolt removal the joint must still remain leak tight. This paper describes the activities performed to ...
2001-07-01
Energy Technology Data Exchange (ETDEWEB)
This Waste Management Plant (WMP) for the Bear Creek Valley Treatability Study addresses waste management requirements for the Oak Ridge Y-12 Plant. The study is intended to produce treatment performance data required to design a treatment system for contaminated groundwater. The treatability study will consist of an evaluation of various treatment media including: continuous column tests, with up to six columns being employed to evaluate the performance of different media in the treatment of groundwater; an evaluation of the denitrifying capacity and metal uptake capacity of a wetland system; and the long-term denitrifying capacity and metal uptake capacity of algal mats. The Sampling and Analysis Plan (SAP) covers the project description, technical objectives, procedures, and planned work activities in greater detail. The Health and Safety Plan (HASP) addresses the health and safety concerns and ...
1997-05-01
Energy Technology Data Exchange (ETDEWEB)
Chapter 2 describes the worldwide increase of primary energy consumption, which is expected in coming decades and results in possible solutions of a decentralised energy supply that is mainly based upon renewable energy carriers and the use of cogeneration systems. Chapter 3 shows the characteristics of decentralised system components that have been investigated in the frame of this research work as well as the resulting model library to depict the operational performance of the individual components and their mutual influence. A detailed dynamic simulation of a complete fuel cell system based on a steam reformer including the concept of local and superordinate control circuits is presented in chapter 4. Chapter 5 includes the integrated concepts for the intelligent and adaptable management of complex decentralised energy systems as well as a description of their implementation. Apart from the applied metaheuristic optimization methods the adaptable fuzzy-system, ...
2007-06-28
Energy Technology Data Exchange (ETDEWEB)
In its current configuration, the IECM provides a capability to model various conventional and advanced processes for controlling air pollutant emissions from coalfired power plants before, during, or after combustion. The principal purpose of the model is to calculate the performance, emissions, and cost of power Plant configurations employing alternative environmental control methods. The model consists of various control technology modules, which may be integrated into a complete utility plant in any desired combination. in conuwt to conventional deterministic models, the IECM offers the unique capability to assign probabilistic values to all model input parameters, and to obtain probabilistic outputs in the form of cumulative distribution functions indicating the likelihood of different costs and performance results. The most recent version of the IECM, implemented on a ...
1993-01-01
Development of the integrated environmental control model
Energy Technology Data Exchange (ETDEWEB)
In its current configuration, the IECM provides a capability to model various conventional and advanced processes for controlling air pollutant emissions from coalfired power plants before, during, or after combustion. The principal purpose of the model is to calculate the performance, emissions, and cost of power Plant configurations employing alternative environmental control methods. The model consists of various control technology modules, which may be integrated into a complete utility plant in any desired combination. in conuwt to conventional deterministic models, the IECM offers the unique capability to assign probabilistic values to all model input parameters, and to obtain probabilistic outputs in the form of cumulative distribution functions indicating the likelihood of different costs and performance results. The most recent version of the IECM, implemented on a ...
1993-01-01
International Nuclear Information System (INIS)
Various kinds of decontaminations are carried out in atomic power plant. Here current decontamination technologies such as chemical decontamination with chemical solution or blast decontamination have a problem of reduction of secondary radioactive waste generated in the decontamination process. On the other hand, a low pressure arc plasma can remove metal oxide film on the metal substrate without heavy damage on the metal substrate when the object to be treated was set as a cathode. Dry surface decontamination technology with using low-pressure arc plasma can decrease secondary radioactive waste because low-pressure arc plasma does not need any chemical solution. In addition, the time required for treatment can be shorter, so it is possible for the low-pressure arc plasma decontamination technology to interpolate the current decontamination technologies such as spot decontamination technology etc. Therefore we have been investigating the dependence of removal of ...
2008-12-01
Energy Technology Data Exchange (ETDEWEB)
The Institute of Energetic and Nuclear Research - IPEN is a research and development institution, located in a densely populated area, in the city of Sao Paulo. The nuclear fuel cycle was developed from the Yellow Cake to the enrichment and reconversion at IPEN. After this phase, all the technology was transferred to private enterprises and to the Brazilian Navy (CTM/SP). Some plants of the fuel cycle were at semi-industrial level, with a production over 20 kg/h. As a research institute, IPEN accomplished its function of the fuel cycle, developing and transferring technology. With the necessity of space for the implementation of new projects, the uranium hexafluoride (UF{sub 6}) production plant was chosen, since it had been idle for many years and presented potential leaking risks, which could cause environmental aggression and serious accidents. This plant decommission required accurate planning, as this work had not been ...
2008-07-01
Risk-based inspection in ASME Section XI
International Nuclear Information System (INIS)
By 1970 the first edition of the ASME Code Section XI, Inservice Inspection of Nuclear Reactor Coolant Systems was published. From its inception, the Section XI inservice inspection scope was based on a fundamental risk-based selection process. In other words the inservice inspection scope included components where the consequences of a pressure boundary failure were high. Once the consequence significant system boundaries were established, inspections would then be performed at locations believed to be most susceptible service induced failure. Current Section XI requirements require that inspection locations be selected on the basis of peak stress and fatigue usage values contained in the Design Reports. These original stress calculations were designed to qualify a design and assure that the plant would provide reliable service throughout its design life. For the most part, the fatigue usage values in these reports do not provide an accurate ...
1996-07-21
Energy Technology Data Exchange (ETDEWEB)
This is a build-and-scrap-and-build job, in which a new No. 1 generator is constructed while the existing plant stays in operation in the same site. Since interference between the new and the existing systems are unavoidable in such work, protection is sufficiently provided and measurements are frequently performed when the work comes to involve important structures positioned close to each other, such as the existing No. 1 and No. 2 OF (oil-filled) cables transmitting power from the existing power plant to Minami-Yokohama Substation of Tokyo Electric Power Co., Ltd., and the newly planned discharge channel or the existing covered sewerage and the newly planned discharge outlet. Now that the newly planned discharge channel intercepts the OF cables at three places and is installed to pass under the existing cable duct, it once happened that the duct supporting piles were severed for the cables to suspend in the air though ...
1998-09-05
Energy Technology Data Exchange (ETDEWEB)
A monitoring campaign of polychlorinated dibenzo-p-dioxins and dibenzofurans, polyaromatic hydrocarbons (PAHs), and polychlorinated biphenyl was carried out in an Italian iron ore sintering plant by sampling the combustion gases at the electrostatic precipitator (ESP) outlet, at the Wetfine scrubber (WS) outlet, and by collecting the ESP dust. Few data are available on these micropollutants produced in iron ore sintering plants, particularly from Italian plants. This study investigates the PAH emission profiles and the removal efficiency of ESPs and WS. PAHs were determined at the stack, ESP outlet flue gases, and in ESP dust to characterize the emission profiles and the performance of the ESP and the WS for reducing PAH emission. The 11 PAHs monitored are listed in the Italian legislative decree 152/2006. The mean total PAH sum concentration in the stack flue gases is 3.96 {mu}g/N m{sup 3}, in ESP ...
2008-11-15
Gas turbine applications in the drying industry
Energy Technology Data Exchange (ETDEWEB)
The purpose of this report is to determine if it is feasible to utilize the hot exhaust gas discharged from gas turbines in direct applications. This report illustrates the technical feasibility and economic viability of using gas turbines in drying applications. The size of turbines in this investigation ranges from 2 MW to 10 MW. In addition, an implementation strategy has been developed to employ this new system. The method used to structure the scope of this undertaking is as follows: Step 1. Collecting information by contacting dryer manufacturer and companies drying different products. Information was also gathered by literature studies and the internet. Thomas register is a great tool when it comes to company and market searches. Step 2. Looking into if it is technically possible to use the exhaust gas directly into dryers. The parameters needed for these calculations were gathered in step 1, and some of the more important are temperature, mass flow, heat demand, and information ...
2000-07-01
Fate of Mercury in Synthetic Gypsum Used for Wallboard Production
Energy Technology Data Exchange (ETDEWEB)
This report presents and discusses results from Task 5 of the study ''Fate of Mercury in Synthetic Gypsum Used for Wallboard Production,'' performed at a full-scale commercial wallboard plant. Synthetic gypsum produced by wet flue gas desulfurization (FGD) systems on coal-fired power plants is commonly used in the manufacture of wallboard. The FGD process is used to control the sulfur dioxide emissions which would result in acid rain if not controlled. This practice has long benefited the environment by recycling the FGD gypsum byproduct, which is becoming available in increasing quantities, decreasing the need to landfill this material, and increasing the sustainable design of the wallboard product. However, new concerns have arisen as recent mercury control strategies developed for power plants involve the capture of mercury in FGD systems. The objective of this ...
2006-06-01
Energy Technology Data Exchange (ETDEWEB)
In the research of a more efficient, less costly, more environmentally responsible and less technically difficult method for generating electrical power from coal, `the Partially Gasified Coal Fired Combined Cycle with a CFBC with Different Speeds (DFBC)` is introduced by Tsinghua University. The high efficiency cycle includes gasification, compressed air heating in a fluidized bed immersed air heater followed by a combustor and the heat recovery of gas turbine exhausted gas used as the combustion of coal in the differential-velocity atmospheric circulating fluidized bed. Superheated steam is raised in the DFBC boiler. A preliminary analysis is made for the choice of combined cycle components. The computer program can be used to evaluate the design and off-design performance of the power plant. The simulation results show that the new system is a valuable coal fired combined cycle system for China, mainly to the improvement of the existing ...
1996-12-31
Simulation for transient stability study of the Taiwan power system - a nuclear majority system
Energy Technology Data Exchange (ETDEWEB)
A transient stability program was developed for the Taiwan Power Company, which has a high proportion of nuclear generation in its power system. This program offers a new territory to investigate nuclear plant effects on the power system transient stability. This program also provides a high speed tool for the Taipower system operational planning. A generalized procedure of synchronous machine modeling for a large-scale stability study is presented. The merits and weaknesses of machine modeling can be comprehended through each item of this procedure. Three types of nonlinear synchronous machine modeling implemented into this stability program are derived by following this procedure. A robust subroutine was derived to perform the fourth order Runge-Kutta integration method, making the software programming neat and systematical. For simulating the nuclear plant influence on the system, this program implemented an additional ...
1984-01-01
Simulation for transient stability study of the Taiwan power system - a nuclear majority system
International Nuclear Information System (INIS)
A transient stability program was developed for the Taiwan Power Company, which has a high proportion of nuclear generation in its power system. This program offers a new territory to investigate nuclear plant effects on the power system transient stability. This program also provides a high speed tool for the Taipower system operational planning. A generalized procedure of synchronous machine modeling for a large-scale stability study is presented. The merits and weaknesses of machine modeling can be comprehended through each item of this procedure. Three types of nonlinear synchronous machine modeling implemented into this stability program are derived by following this procedure. A robust subroutine was derived to perform the fourth order Runge-Kutta integration method, making the software programming neat and systematical. For simulating the nuclear plant influence on the system, this program implemented an additional ...
International Nuclear Information System (INIS)
During the past 2 yr, significant progress has been made in several areas related to the safety and environmental (S and E) aspects of inertial fusion energy (IFE). An updated methodology has been developed, and accident analyses have been performed for two IFE conceptual power plants and a target fabrication facility. Parallel to the consequence analyses of different accident scenarios, ongoing studies of accident initiating events are being used to support safety assessment and create a basic framework of types of events to consider in future risk characterization of new plant designs. Target designers/fabrication specialists have been provided with ranking information related to the S and E characteristics of candidate target materials. We have revisited waste management options for IFE, introducing the concept of clearance versus the traditional shallow land burial. A brief summary of results in each of these activities ...
2003-05-01
SEAFP-2 bounding accident analyses
Energy Technology Data Exchange (ETDEWEB)
Analyses have been performed of the potential consequences to the public of hypothetical loss-of-coolant accidents in conceptual fusion power plant designs. In order to establish upper bounds to the consequences of such events, a case has been studied in which total loss of all active cooling has been assumed, with no remedial intervention for the duration of the accident sequence. The analyses are based on three conceptual power plant designs, two of them similar to those assumed in the earlier safety and environmental assessment of fusion power (SEAFP) study (Raeder et al., 1995), with updating of assumed structural materials. The three models studied provide a broad range of design options. In all cases the decay-heat driven temperature transients are well below the level at which structural melting would begin. Based on conservative assumptions, mobilisation, release and dose calculations show that potential maximum ...
2000-09-01
Energy Technology Data Exchange (ETDEWEB)
The third regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from December 27, 1988 to May 25, 1989. The parallel operation was resumed on April 28, 1989, 123 days after the parallel off. The facilities which were the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation and emergency electric power generation system. On the facilities which were the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out. As the results, significant in indication was observed in 8 bolts for fixing the flow-changing vanes of primary coolant pumps, and broken valve spindles were found, but other abnormality was not found. The works related to this regular inspection were accomplished within the range of the limit of radiation ...
1990-03-01
International Nuclear Information System (INIS)
The second regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from October 5, 1987 to January 8, 1988. the parallel operation was resumed on December 8, 1987, 65 days after the parallel off. The facilities as the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation, and emergency power generation system. On these facilities as the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out, and abnormality was not found at all. The works related to this regular inspection were accomplished within the range of allowable dose based on the relevant laws. The main reconstruction works carried out during the period of this regular inspection were the change of the degree of enrichment from 3.15 wt.% to 3.4 wt.% for ...
1988-01-01
Energy Technology Data Exchange (ETDEWEB)
The second regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from October 5, 1987 to January 8, 1988. the parallel operation was resumed on December 8, 1987, 65 days after the parallel off. The facilities as the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation, and emergency power generation system. On these facilities as the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out, and abnormality was not found at all. The works related to this regular inspection were accomplished within the range of allowable dose based on the relevant laws. The main reconstruction works carried out during the period of this regular inspection were the change of the degree of enrichment from 3.15 wt.% to 3.4 wt.% for ...
1988-08-01
Results of Compact Stellarator Engineering Trade Studies
Energy Technology Data Exchange (ETDEWEB)
number of technical requirements and performance criteria can drive stellarator costs, e.g., tight tolerances, accurate coil positioning, low aspect ratio (compactness), choice of assembly strategy, metrology, and complexity of the stellarator coil geometry. With the completion of a seven-year design and construction effort of the National Compact Stellarator Experiment (NCSX) it is useful to interject the NCSX experience along with the collective experiences of the NCSX stellarator community to improving the stellarator configuration. Can improvements in maintenance be achieved by altering the stellarator magnet configuration with changes in the coil shape or with the combination of trim coils? Can a mechanical configuration be identified that incorporates a partial set of shaped fixed stellarator coils along with some removable coil set to enhance the overall machine maintenance? Are there other approaches that will simplify the concepts, improve access for ...
2009-05-27
Results of Compact Stellarator Eengineering Trade Studies
Energy Technology Data Exchange (ETDEWEB)
A number of technical requirements and performance criteria can drive stellarator costs, e.g., tight tolerances, accurate coil positioning, low aspect ratio (compactness), choice of assembly strategy, metrology, and complexity of the stellarator coil geometry. With the completion of a seven-year design and construction effort of the National Compact Stellarator Experiment (NCSX) it is useful to interject the NCSX experience along with the collective experiences of the NCSX stellarator community to improving the stellarator configuration. Can improvements in maintenance be achieved by altering the stellarator magnet configuration with changes in the coil shape or with the combination of trim coils? Can a mechanical configuration be identified that incorporates a partial set of shaped fixed stellarator coils along with some removable coil set to enhance the overall machine maintenance? Are there other approaches that will simplify the concepts, improve access for ...
2009-09-25
Energy Technology Data Exchange (ETDEWEB)
Heat exchangers for high and ultrahigh temperatures are a need and a precondition to realise high efficient fossil fired power plants based on the so-called Externally Fired Combined Cycle (EFCC) or the Indirect Fired Gas Turbines (IFGT). The main target of both processes is to increase the thermal efficiency of existing power plants by approximately 25% resulting in the same decrease in fuel consumption and, therefore, in the same reduction of CO{sub 2} formation. The main activities of the MPA University of Stuttgart in this project is focused on the characterisation and qualification of the structural material of the ultrahigh temperature heat exchanger (UHTHE) necessary in the above mentioned processes. The influence of the temperature and load on the material behaviour have been analysed by means of tensile tests and creep tests. The effectiveness of different coating systems and the interaction between coating system and basic material ...
2004-07-01
Energy Technology Data Exchange (ETDEWEB)
This paper investigates various usages of natural gas (NG) as an energy source for different hydrogen production technologies. A comparison is made between the different methods of hydrogen production, based on the total amount of natural gas needed to produce a specific quantity of hydrogen, carbon dioxide emissions per mole of hydrogen produced, water requirements per mole of hydrogen produced, and a cost sensitivity analysis that takes into account the fuel cost, carbon dioxide capture cost and a carbon tax. The methods examined are the copper-chlorine (Cu-Cl) thermochemical cycle, steam methane reforming (SMR) and a modified sulfur-iodine (S-I) thermochemical cycle. Also, an integrated Cu-Cl/SMR plant is examined to show the unique advantages of modifying existing SMR plants with new hydrogen production technology. The analysis shows that the thermochemical Cu-Cl cycle out-performs the other conventional methods with ...
2010-08-15
International Nuclear Information System (INIS)
This paper investigates various usages of natural gas (NG) as an energy source for different hydrogen production technologies. A comparison is made between the different methods of hydrogen production, based on the total amount of natural gas needed to produce a specific quantity of hydrogen, carbon dioxide emissions per mole of hydrogen produced, water requirements per mole of hydrogen produced, and a cost sensitivity analysis that takes into account the fuel cost, carbon dioxide capture cost and a carbon tax. The methods examined are the copper-chlorine (Cu-Cl) thermochemical cycle, steam methane reforming (SMR) and a modified sulfur-iodine (S-I) thermochemical cycle. Also, an integrated Cu-Cl/SMR plant is examined to show the unique advantages of modifying existing SMR plants with new hydrogen production technology. The analysis shows that the thermochemical Cu-Cl cycle out-performs the other conventional methods with ...
2010-08-01
Material and process improvements in condenser tubing
Energy Technology Data Exchange (ETDEWEB)
The reliability of the surface condenser is a key factor in plant performance level and maintenance cost optimization. This is especially the case for thermal nuclear plants where condenser raw wa-ter ingress can introduce contamination into the chemically-controlled, steam/water loop potentially causing damage to sensitive equipment. Two important parameters must be taken into account when attempting to optimize the quality and the reliability of condenser tubing. They include selecting the appropriate material according to the cooling water corrosion level present. A second and equally important parameter is the manufac-turing of the tubing product itself. This paper will identify methods to optimize manufacturing processes and improve tubing quality, according to VALTIMET's 30 years of condenser welded tubing production experience. Those methods complete the core manufacturing process (forming and welding), ...
2010-07-01
Macrofouling control in nuclear power plants
International Nuclear Information System (INIS)
Macrofouling of cooling-water systems is one of the more significant and costly problems encountered in the nuclear power industry. Both marine and freshwater macroinvertebrates can be responsible for losses in plant availability because of plugged intakes and heat transfer equipment. There is a greater diversity of macrofouling organisms in marine waters than in fresh waters. Marine macrofouling organisms include barnacles, mollusks, bryozoans, and hydroids. Barnacles are crustaceans with feathery appendages, which allow them to attach to a variety of surfaces. They are a major cause of severe macrofouling because they can remain attached even after death. The major freshwater macrofouling organisms include the Asiatic Clam (Corbicula fluminea) and the newest freshwater macrofouler, the Zebra Mussel (Dreissena polymorpha). The introduction of the Zebra Mussel into the Great Lakes has created economic and ecological problems that will not easily be solved. The ...
1991-11-10
Long-term corrosion study at nuclear power plant Bohunice (Slovakia)
International Nuclear Information System (INIS)
Steam generators of four VVER-440 units at nuclear power plants V-1 and V-2 in Jaslovske Bohunice (Slovakia) were gradually changed by new original 'Bohunice' design in period 1994-1998. Corrosion processes before and after these design and material changes in Bohunice secondary circuit were studied using Moessbauer spectroscopy during last 25 years. Innovations in the feed water pipeline design as well as material composition improvements were evaluated positively. Moessbauer spectroscopy studies of phase composition of corrosion products were performed on real specimens scrapped from water pipelines or in form of filter deposits. The corrosion of new feed water pipelines system (from austenitic steel) in combination to innovated operation regimes goes dominantly to magnetite. The hematite presence is mostly on the internal surface of steam generator body and its concentration increases towards the top of the body. In the results ...
2010-03-01
FFTF [Fast Flux Test Facility] fuel handling experience (1979--1986)
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF)is a 400 MW (th) sodium-cooled fast flux test reactor located on the Hanford Site in southeastern Washington State. The FFTF is operated by the Westinghouse Hanford Company for the United States Department of Energy. The FFTF is a three loop plant designed primarily for the purpose of testing full-scale core components in an environment prototypic of future liquid metal reactors. The plant design emphasizes features to enhance this test capability, especially in the area of the core, reactor vessel, and refueling system. Eight special test positions are provided in the vessel head to permit contact instrumented experiments to be installed and irradiated. These test positions effectively divide the core into three sectors. Each sector requires its own In-Vessel Handling Machine (IVHM) to access all the core positions. Since the core and the in-vessel refueling components are submerged under sodium, all handling ...
1987-09-01
Effectively use corrosion testing
Energy Technology Data Exchange (ETDEWEB)
The proper selection of materials of construction is necessary to provide process equipment with optimum performance and corrosion resistance. If properly chosen, the selected material should deteriorate at a uniform, predictable rate, which will allow for maintenance or replacement at scheduled intervals. This concept of risk assessment for predictive maintenance is a minimum requirement for proper materials selection. Materials selection is based on prior service history, field corrosion tests, pilot-plant tests, and laboratory bench-top tests--in that relative order of usefulness. Corrosion test methods are usually divided into two groups: laboratory and field (plant-site) tests. The main difference between the two is that field test specimens are exposed to actual process conditions will all of the variables involved, while laboratory tests are a simulation of field conditions, even if actual process fluids are ...
1995-04-01
Development of a new evaporator using hydrophobic membrane for radioactive liquid waste
Energy Technology Data Exchange (ETDEWEB)
An evaporator using a hydrophobic membrane made from a polytetrafluoroethylene (PTFE) was developed to improve DF (Decontamination Factor) and to reduce evaporator size. The membrane distillation, provided by the evaporator, is a new technique for liquid purification. Fundamental experiments were carried out to develop the membrane filter (tube type, outer diameter, 8 mm; membrane thickness, 500 {mu}m) for radioactive liquid treatment. The continuous operation test using actual liquid waste was also made during about 3,000 h. (This is almost equal to the operation time of an actual evaporator per year.) The evaporation rate decreased with increase an operation time due to contamination of waste impurity. But the rate was recovered by washing the membrane with hot water and then drying it. DF was over 10{sup 4} which is ten times larger than that for a conventional system. A pilot plant (capacity, 200 kg-liquid waste/h) was constructed and its ...
1996-10-01
Conversion of the Midland nuclear station
Energy Technology Data Exchange (ETDEWEB)
The authors report how the Midland cogeneration venture (MCV) is repowering the incomplete Midland nuclear plant to operate as a gas-fired combined cycle cogeneration facility. They discuss how their company is responsible for performing engineering, procurement, licensing, construction, start-up, training, and operational assistance for this facility. As shown, twelve gas turbine generator sets supply heat to twelve heat recovery steam generators (HRSGs), which are headered together on the steam side to provide energy to either of two existing steam turbine generators. This combination of equipment enables approximately 1,380 MWe of electrical generation capability, while supplying an average steam flow of 629,000 lbs/hr to an adjacent Dow Chemical Company pant. The MCV facility will also provide 60 MW of electric power to Dow. The authors report how the Midland ccogeneration venture (MCV) is repowering the incomplete Midland nuclear ...
1988-01-01
Control of the reduction/oxidation potential of Hanford Waste Vitrification Plant feeds
International Nuclear Information System (INIS)
A schematic diagram shows the various processing steps to be performed during feed preparation in the Hanford Waste Vitrification Plant (HWVP). The pretreated NCAW is transferred to the slurry receipt adjustment tank (SRAT) in the HWVP for concentration. Water removed during boildown is collected in the slurry mix evaporator condensate tank (SMECT). After waste treatment the water is returned to the storage tanks for eventual disposal. The pretreated Neutralized Current Acid Waste (NCAW) is concentrated in the SRAT to approximately 125 g waste oxides/ liter. Formic acid is then added at a controlled rate to improve rheological properties and achieve a required reduction/oxidation state. Reflux boiling is initiated and continued for several hours. The concentrated slurry is cooled and pumped to the slurry mix evaporator (SME). In the SME, glass frit is added, and the slurry is further concentrated to achieve a nominal composition of 500 g total ...
1988-09-11
Energy Technology Data Exchange (ETDEWEB)
The predicted results of INDAC code were compared with measured {sup 3}H concentrations in air and pine-needle around the Wolsung site. The optimal sets of input data to INDAC were in addition selected by comparing the measured values with the predicted values of INDAC based on various conditions such as the release modes of effluents into the environment, the classification of wind classes, and the consideration of terrain. The predicted {sup 3}H concentrations in air and pine-needle were shown to have good agreement with measured values, although there are some limitations such as uncertainties in measured values, complex topology around the site, and the land-sea breeze effects. The assumption on the {sup 3}H behavior in vegetables or plants that the ratio of {sup 3}H concentration in plant water to {sup 3}H concentration in atmospheric water is 1/2 was shown to be conservative in terms of the audit calculation performed ...
2000-06-15
International Nuclear Information System (INIS)
The predicted results of INDAC code were compared with measured "3H concentrations in air and pine-needle around the Wolsung site. The optimal sets of input data to INDAC were in addition selected by comparing the measured values with the predicted values of INDAC based on various conditions such as the release modes of effluents into the environment, the classification of wind classes, and the consideration of terrain. The predicted "3H concentrations in air and pine-needle were shown to have good agreement with measured values, although there are some limitations such as uncertainties in measured values, complex topology around the site, and the land-sea breeze effects. The assumption on the "3H behavior in vegetables or plants that the ratio of "3H concentration in plant water to "3H concentration in atmospheric water is 1/2 was shown to be conservative in terms of the audit calculation performed by the regulator. It was ...
2000-06-01
Coal quality engineering analysis aids plant performance
Energy Technology Data Exchange (ETDEWEB)
The Coal Quality Engineering Analysis (CQEA) program developed by the New York State Electric and Gas Company (NYSEC) calculates the as-burned cost of burning a specific coal in a specific generation unit. These costs include: maintenance costs for coal and ash handling equipment; ash disposal costs; cost of oil (if required for flame stability and/or derating because of pulverizer capacity limitation); flue gas desulfurization costs; cost of replacement power caused by pulverizer, precipitator fly ash collection and bottom ash capacity limitation; boiler losses due to moisture, hydrogen, dry gas and unburned carbon; power for coal and ash handling equipment; power for coal pulverizers; cost of using excess air to prevent slagging of coal with low ash softening temperatures; and effect of heat rate on coal tonnage required for a desired generation. The use of CQEA to identify areas in which plant operations may be improved is discussed. 7 figs., 1 tab.
1988-10-01
Application of SGFM technology to alternate feedstocks. Phase III
Energy Technology Data Exchange (ETDEWEB)
The Synthesis Gas From Manure (SGFM) pilot plant was constructed at Texas Tech University to evaluate the gasification of cattle feedlot manure. A study of gas yield and composition as a function of operating conditions was performed. This report presents the results of a comparison of feedstocks other than manure in the pilot plant. Oak sawdust was the superior feedstock tested in terms of both gas yield and operability. Corn stover and mesquite were comparable and presented some handling problems. Cotton gin trash was unacceptable due to low-temperature ash fusion in the reactor. The gas yield from oak sawdust varied from 0.8 to 1.7 1/gm DAF feed at average temperatures of 650 to 770/sup 0/C. The gas contained approximately 15% hydrogen and 40% carbon monoxide by volume. It also contained 5 to 8% methane and 2 to 5% ethylene. All of these results were obtained using steam and air as the gasifying medium.
1980-01-01
An Overview of the Reliability and Availability Data System (RADS)
Energy Technology Data Exchange (ETDEWEB)
The Reliability and Availability Data System (RADS) is a database and analysis code, developed by the Idaho National Engineering and Environmental Laboratory (INEEL) for the U.S. Nuclear Regulatory Commission (USNRC). The code is designed to estimate industry and plant-specific reliability and availability parameters for selected components in risk-important systems and initiating events for use in risk-informed applications. The RADS tool contains data and information based on actual operating experience from U.S. commercial nuclear power plants. The data contained in RADS is kept up-to-date by loading the most current quarter's Equipment Performance and Information Exchange (EPIX) data and by yearly lods of initiating event data from licensee event reports (LERS). The reliability parameters estimated by RADS are (1) probability of failure on demand, (2) failure rate during operation (used to calculate failure to ...
2005-09-01
A study on the fuel handling control system in CANDU 6 nuclear power plants
Energy Technology Data Exchange (ETDEWEB)
The Fuel Handling(F/H) System in existing CANDU 6 nuclear power plants was designed in the early 1960`s, utilizing the technology available at that time. The design for the F/H control system has been proven to be excellent in meeting the functional requirements through more than 20 CANDU units in service or under construction. The significant advance in electrical and electronic engineering area in a few decades motivates the design changes to reduce costs for engineering, construction and operation as well as to improve performance, reliability and safety based on the latest technology. This report outlines the current design of the F/H system, especially for the F/H control system, introduces some topics in research and development projects being carried out by AECL or other institutes, and presents several potential design improvement items for the better CANDU system with brief explanation about implementation. 29 figs., 2 tabs., 27 refs. ...
1994-06-01
A structured approach to the assessment of the quality culture in nuclear installation
International Nuclear Information System (INIS)
INSAG has emphasized that safety culture has two general components: the organizational framework and the attitude of the staff. To develop a structured approach to the assessment of safety culture, we propose that the highly formalized nature of nuclear power plant organizations be exploited. The prime coordinating mechanism of NPP organizations is the standardization of work processes, where a work process is defined as a standardized sequence of tasks designed to achieve a specific goal (an example is the maintenance work process). The predictable nature of work processes is exploited by the Work Process Analysis Model (WPAM) to conduct a systematic analysis that identifies the desirable characteristics of work processes and develops performance measures for their strengths and weaknesses. These can provide a set of tangible characteristics of a good safety culture. It is argued in this paper that the analysis of normal power production and ...
1995-04-01
A novel gas turbine cycle with hydrogen-fueled chemical-looping combustion
Energy Technology Data Exchange (ETDEWEB)
In this paper we have proposed a novel gas turbine cycle with hydrogen-fueled chemical-looping combustion, and the system study on two hydrogen-fueled power plants, the new gas turbine cycle and an advanced gas turbine cycle with H{sub 2}/O{sub 2} combustion, has been investigated with the aid of exergy principle (EUD methodology). The hydrogen fueled chemical-looping combustion in the new gas turbine cycle consists of two successive reactions: hydrogen fuel is reacted with metal oxide (reduction of metal oxide), and then instead of air or pure oxygen, the reduced metal is successively oxidized by the saturated air. As a result, the new hydrogen-fueled gas turbine cycle has a breakthrough performance, with at least about 12 percentage-point higher efficiency compared to the gas turbine cycle with H{sub 2}/O{sub 2} combustion, and will be environmentally superior due to complete elimination of NO{sub x} formation. The promising results obtained ...
2000-12-01
NWIS MEASUREMENTS FOR URANIUM METAL ANNULAR CASTINGS
Energy Technology Data Exchange (ETDEWEB)
This report describes measurements performed with annular uranium metal castings of different enrichments to investigate the use of {sup 252}Cf-source-driven noise analysis measurements as a means to quantify the amount of special nuclear material (SNM) in the casting. This work in FY 97 was sponsored by the Oak Ridge Y-12 Plant and the DOE Office of Technology Development Programs. Previous measurements and calculational studies have shown that many of the signatures obtained from the source-driven measurement are very sensitive to fissile mass. Measurements were performed to assess the applicability of this method to standard annular uranium metal castings at the Oak Ridge Y-12 plant under verification by the International Atomic Energy Agency (IAEA) using the Nuclear Weapons Identification System (NWIS) processor. Before the measurements with different enrichments, a limited study of ...
1998-03-13
Development of a microbiological ammonium to nitrate recycling bioreactor for space capsules
International Nuclear Information System (INIS)
Since 1988, the Expertise group of Molecular and Cellular Biology (MCB) is an important partner in the development of the Micro-Ecological Life Support System Alternative (MELiSSA). The MELiSSA was designed to allow a small crew to survive on an Antarctic, lunar or Mars outpost, and is a joint research project currently fostered by the European Space Agency, ESA. The MELiSSA functions through a series of five interconnected compartments, of which four are microbial bioreactors and was engineered to degrade organic waste, regenerate the outpost's atmosphere and water, and provide the crew with an additional vegetarian diet. The bioreactor of the third compartment provides the edible cyanobacteria and plants of the fourth compartment with nitrate instead of ammonium as a source of nitrogen. The two bacteria responsible for the biological transformation of ammonium to nitrate (nitrification) are Nitrosomonas europaea and Nitrobacter winogradskyi. Since all ...
2009-09-01
UK PubMed Central (United Kingdom)
The concept of plant intelligence, as proposed by Anthony Trewavas, has raised considerable discussion. However, plant intelligence remains loosely defined; often it is either perceived as practically...Full Text Available
2009-05-01
UK PubMed Central (United Kingdom)
BackgroundSenescence is integral to the flowering plant life-cycle. Senescence-like processes occur also in non-angiosperm land plants, algae and photosynthetic prokaryotes. Increasing...Full Text Available
Transient Critical Heat Flux tests on a rod bundle simulating Pressurized Water Reactors
International Nuclear Information System (INIS)
Transients induced in nuclear power plants from many sources result in one or more fluid conditions changing with time. Fluid conditions of pressure, inlet temperature, inlet flow, or even system power many change separately or in conjunction with each other. The result of the condition change may be one which induces departure from nucleate boiling. An experimental investigation of transient which were intended to achieve Critical Heat Flux was performed at the Heat Transfer Research Facility of Columbia University for Siemens Nuclear Power Corporation. The transients were set up to include broad ranges of flow and pressure conditions near the operating range of pressurized water reactors. Transient events were dominated by varying single conditions and measuring the response of the system and of the rod thermocouples. Because of coupling effects within the test loop, secondary conditions would also vary. In order to ...
Treatment feasibility of the radioactive liquid waste originated from MOX fuel characterization
International Nuclear Information System (INIS)
Different types of radioactive liquid waste are being generated at Advanced Fuel Fabrication Facility (AFFF), Tarapur during the quality control analysis of the mixed oxide (MOX) fuel pellets. A laboratory scale study was performed for treatment of such waste. Some of the waste streams originating from U and Pu analysis contain components like sulphate and phosphate which interfere during chemical precipitation of alpha activity from the waste. Various chemical co-precipitation experiments were conducted based on alkaline precipitation. Reductive precipitation using sodium sulphite and Fe(II) was found to be promising and the same was suggested for plant scale treatment. (author)
2011-02-22
Technology evaluation report for the Buried Waste Robotics Program Subsurface Mapping Project
International Nuclear Information System (INIS)
This document presents a summary of the work performed in support of the Buried Waste Robotics Program Subsurface Mapping Project. The project objective was to demonstrate the feasibility of remotely characterizing buried waste sites. To fulfill this objective, a remotely-operated vehicle, equipped with several sensors, was deployed at the Idaho National Engineering Laboratory. Descriptions of the equipment and areas involved in the project are included in this report. Additionally, this document provides data that was obtained during characterization operations at the Cold Test Pit and the Subsurface Disposal Area, both at the Idaho National Engineering Laboratory's Radioactive Waste Management Complex, and at the Idaho Chemical Processing Plant. The knowledge gained from the experience, that can be applied to the next generation remote-characterization system, is extensive and is presented in this report.
Techno-economic investigation of an air humidification-dehumidification desalination process
Energy Technology Data Exchange (ETDEWEB)
This article presents a humidification-dehumidification (H.D.) process suitable for desalination of sea- and brackish water. The work correlated performance characteristics of the combination of different components in such a loop. Water yield, energy requirement and design data are evaluated as functions of different parameters. The investigation covered water to air mass ratios ranging from 60 to 80, concentration ratios between 2 and 5, at a temperature difference of between 10 and 16 C, along the liquid for dehumidification. The results showed that 76% of energy consumed in the humidifier is recovered by condensation. Increase of the concentration ratio to 5 can reduce the make-up water and rejected brine by about 58% and 24% respectively. Cost calculations show that the H.D. process has significant potential as an alternative for small capacity desalination plants and permits to operate systems as small as 10 m[sup 3]/day in output. ...
1993-08-01
Technical Standards for Wolsong Unit 1 Nuclear Power Plant
International Nuclear Information System (INIS)
More than twenty years after commencing commercial operation in 1983, Wolsong Unit 1(W1- NPP), the first CANDU Pressurized Heavy Water Reactor (PHWR) in Korea, has been undergoing refurbishment. Safety analyses were required to evaluate the safety of W1-NPP because significant amount of equipment has been refurbished. To evaluate the effectiveness of W1-NPP after these upgrades, new safety analyses were performed using the same technical standards of Wolsong Units 2, 3, 4 (W234-NPP) for Design Basis Accidents (DBA). The refurbished W1- NPP is expected to be licensed for full power operation based on the verified safety analysis results that are obtained by using the upgraded computer codes and newly adopted technical standards of W234-NPP
2010-10-01
Surface analysis by Fourier-transform infrared (FTIR) spectroscopy
Energy Technology Data Exchange (ETDEWEB)
A diffuse-reflectance capability for the Fourier transform infrared spectrometer at the Y-12 Plant Laboratory has been implemented. A sample cell with a 25 to 400/sup 0/C temperature-controlled sample stage and an ultrahigh-vacuum-to-atmospheric pressure gas-handling capability has been developed. Absorbance of light from the spectrometer beam, resulting from the beam being scattered from a powder sample, can be measured. This capability of detecting molecular species on and in powders is to be used to study chemisorption on actinide and rare-earth metals, alloys, and compounds. Cell design is described along with experiments demonstrating its performance in detecting moisture absorption on uranium oxide, moisture and carbon dioxide absorption on the lithium hydride/hydroxide system, and carbon dioxide absorption on potassium borohydride. 13 figures.
1981-08-12
Sodium hideout studies in steam generator crevices
International Nuclear Information System (INIS)
The steam generator availability is one of the important problems encountered during the pressurized water nuclear plant operation. Various kinds of corrosion phenomena were observed in the past. These phenomena result from the concentration of impurities mainly in three locations in the steam generators: the tubesheet crevices, the tube support plate crevices, and the sludge pile. Corrections were made in the design and the materials used but a number of steam generators suffer or will suffer from corrosion processes inducing in many cases forcing their replacement. In order to prevent or to retard the corrosions several laboratories have performed experiments to reproduce and to study the corrosion processes. The first step of the degradation is the concentration of chemical species. A method using /sup 24/Na as a radioactive tracer was used to establish the concentration kinetics of caustic which was identified as the major cause of the ...
Significance of chemical return in nuclear steam generators
International Nuclear Information System (INIS)
A reasonable understanding of PWR steam generator corrosion mechanisms such as denting and wastage has been developed, and adequate chemistry control programs defined to obviate the magnitude and effects of these modes of attack. However, relatively unique corrosion attack modes have been encountered at several plants notwithstanding the presence of a reasonable to very good chemistry control program when considered in light of the Steam Generator Owners Group chemistry guidelines. The uniqueness of attack also suggests that parameters not routinely measured or monitored may be playing a significant role. In the authors opinions, the only reasonable method of routinely identifying corrosion accelerating species present in crevices, sludge piles, and deposits in PWR steam generators is by performing detailed chemical return studies during power transients, shutdowns, and long term layups. Although it would be preferable to obtain samples from ...
1985-03-01
Severe accident analysis for Wolsung nuclear power
Energy Technology Data Exchange (ETDEWEB)
Severe accident analysis has been performed for the Wolsung nuclear power plants in Korea to investigate severe accident phenomena of CANDU-600 reactors as a part of Level II PSA study. The accident sequence analyzed in this paper is loss of active heat sinks (LOAH) which is caused by loss of off-site power, diesel generators, and DC power, ISAAC(Integrated Severe Accident Analysis Code) computer code developed by KAERI (Korea Atomic Energy Research Institute) was used in this analysis. This paper describes the important thermal-hydraulics and source term behaviors in the primary system and inside containment, and the failure mechanisms of calandria vessel and containment. In addition, some insights for accident management program (AMP) are also given.
1997-05-01
Research and development on next generation reactor (phase I)
Energy Technology Data Exchange (ETDEWEB)
The objective of the study is to improve the volume of nuclear power plant which adopts passive safety system concept. The passive safety system reactor is characterized by excellent safety and reliability. But the volume of NSSS (Nuclear Steam Supply System) of the passive safety system reactor is so small that it should be upgraded for commercial operation. For volume upgrade, detailed analyses are performed as follows; core design, hydraulics, design and mechnical structures, and safety analysis. In addition to above analysis, some investigations must be supplied as follows: power density vs. DNB margin decrease, outlet temperature vs. EPRI-URD, additional tests for upgraded reactor, dynamic analysis of mechanical vibration according to expanded reactor vessel and expanded in-core structures, and Merit loss of passive safety system reactor according to design margin decrease. (Author).
1994-10-01
Report of the technical committee meeting 1997 annual workshop on ASSET experience and feedback
International Nuclear Information System (INIS)
Papers and presentations were made by all participating countries and provided a wide range of perspectives on the use of the ASSET methodology. Generally, the views expressed were positive, however, there were comments on areas were the service could be improved or enhanced. The workshop was divided into three task groups to analyze the self-assessments conducted at Krsko NPP, Slovenia; Dukovany NPP, Czech Republic; and Balakovo NPP, Russian Federation. In addition, they were asked to comment on the recommendations on the ASSET service made by the Consultants' Meeting of 26-30 August 1996 on ''Performance of the IAEA programme on Operational Safety Services''. A presentation was made by Mr. B. Thomas to remind delegates of the ASSET methodologies, and Mr. V. Sivokon demonstrated the latest developments of computer software available for assisting in the plant Self-Assessment process. Refs, figs, tabs.
1997-06-24
Reflux boiling heat removal in a scaled TMI-2 system test facility
International Nuclear Information System (INIS)
An investigation of decay heat removal by the reflux boiling process was performed on a 1/18 linear-scaled test facility simulating the Three Mile Island (TMI-2) primary system. The objective was to clarify reflux boiling phenomena and core cooling effectiveness. Principal test variables included: core power, primary system water and gas inventories, and steam generator secondary-side coolant flow rate. Of 49 tests conducted, 43 achieved a steady-state heat rejection mode within 3 hours. Subsequent analyses identified two distinct reflux boiling modes. Based upon our current understanding, reflux boiling appears to be an effective process for removing decay heat in a broad range of the conditions investigated for a plant of the TMI configuration.
1980-06-01
Reduction of statistic error in Mihalczo subcriticality measurement
Energy Technology Data Exchange (ETDEWEB)
The theoretical formula for the statistical error estimation in Mihalczo method was derived, and the dependence of the error were investigated on the facility to be measured and on the parameter in the data analysis. The formula was derived based on the reactor noise theory and the error theory for the frequency analysis, and found that the error depends on such parameters as the prompt neutron decay constant, detector efficiencies, and the frequency bandwidth. Statistical errors estimated with the formula was compared with experimental values and verified to be reasonable. Through parameter surveys, it is found that there is an optimum combination of the parameters to reduce the magnitude of the errors. In the experiment performed in DCA subcriticality measurement facility, it is estimated experimentally that the measurement requires 20 minutes to obtain the statistic error of 1% for the keff 0.9. According to the error theory, this might be reduced to 3 seconds ...
1998-08-01
Recommendations for a proposed standard for performing systems analysis
In August 1995, the Nuclear Regulatory Commission (NRC) issued a policy statement proposing improved regulatory decisionmaking by increasing the use of PRA [probabilistic risk assessment] in all regulatory matters to the extent supported by the state-of-the-art in PRA methods and data. A key aspect in using PRA in risk-informed regulatory activities is establishing the appropriate scope and attributes of the PRA. In this regard, ASME decided to develop a consensus PRA Standard. The objective is to develop a PRA Standard such that the technical quality of nuclear plant PRAs will be sufficient to support risk-informed regulatory applications. This paper presents examples recommendations for the systems analysis element of a PRA for incorporation into the ASME PRA Standard.
1998-08-01
Recommendations for a proposed standard for performing systems analysis
Energy Technology Data Exchange (ETDEWEB)
In August 1995, the US Nuclear Regulatory Commission (NRC) issued a policy statement proposing improved regulatory decision making by increasing the use of probabilistic risk assessment (PRA) in all regulatory matters to the extent supported by the state-of-the-art in PRA methods and data. A key aspect in using PRA in risk-informed regulatory activities is establishing the appropriate scope and attributes of the PRA. In this regard, the American Society of Mechanical Engineers (ASME) decided to develop a consensus PRA standard. The objective is to develop a PRA standard such that the technical quality of nuclear plant PRAs will be sufficient to support risk-informed regulatory applications. The authors present example recommendations for the systems analysis element of a PRA for incorporation into the ASME PRA standard.
1998-12-31
Energy Technology Data Exchange (ETDEWEB)
The Nuclear Fuel Technology Department (NFTD) in CNRTC is a unique unit in Turkey in charge of performing all activities in nuclear fuel field. It has a pilot plant on uranium refining and conversion to UO{sub 2} since 1986. Presently, its R and D activities are focused on pellet manufacturing and characterization: UO{sub 2}, ThO{sub 2}and (Th,U)O{sub 2}. The studies on thorium dioxide fuel include to obtain ThO{sub 2} pellets from thorium nitrate and mixed (Th,U)O{sub 2} pellets. A study on evaluation of different fuel cycle options in accordance with nuclear energy planning in Turkey is also going on. (author)
1997-07-01
RTA dual-fuel engine - natural gas instead of diesel oil
Energy Technology Data Exchange (ETDEWEB)
Test bed trials of the Sulzer RTA84 dual-fuel engine were successfully completed at the IHI Aioi engine works (Japan) in April 1986. This newly-developed engine-type, output range 15 to 40 MW, can be operated with both diesel or heavy oil and methane gas at comparable thermal efficiency and unchanged output. The RTA dual-fuel engine was developed in close collaboration between Sulzer Brothers Limited and its Japanese licenses. Intended for the propulsion of LNG carriers, where the boil-off gas from the ship's cargo is exploited for the generation of electricity in stationary plants, the RTA dual-fuel engines is an economic and reliable alternative to the steam or gas turbine. The performance of the engine is discussed.
1987-01-01
Energy Technology Data Exchange (ETDEWEB)
Research facilities and personnel in high efficiency separation processes for carbon dioxide removal from industrial sources, such as fossil fuel fired power stations, goal gasification plants, and hydrogen production units for enhanced oil recovery applications at the University of Regina were described. A brief summary of current projects, such as the determination of CO{sub 2} absorption capacity of sterically hindered amines, the formulation of high CO{sub 2} absorption capacity solvents, the search for high performance absorbers and regenerators, studies on material corrosion, and optimization and cost studies of co-production of CO{sub 2} and electricity, was also provided.
1997-02-01
International Nuclear Information System (INIS)
Joint FAO/IAEA/WHO Expert Committee approved the use of radiation treatment of foods. Nowadays food packaging are mostly made of plastics, natural or synthetic, therefore effect of irradiation on these materials is crucial for packing engineering for food irradiation technology. By selecting the right polymer materials for food packaging it can be ensured that the critical elements of material and product performance are not compromised. When packaging materials are in contact with food at the time of irradiation that regulatory approvals sometimes apply. The review of the R-and-D and technical papers regarding material selection, testing and approval is presented in the report. The most information come from the USA where this subject is well elaborated, the International Atomic Energy Agency (IAEA) reports are reviewed as well. The report can be useful for scientists and food irradiation plants operators. (author)
Numerical methods for thermal-hydraulics and structure in nuclear engineering
International Nuclear Information System (INIS)
Designs of nuclear reactor plants aim for high performance under safety consideration. Because of large scale and high pressure/temperature conditions, data from costly mockup tests have been required to verify simulation codes of systems and components. Establishment of design by analysis (DBA) in nuclear engineering is required for development of next generation nuclear reactors. Recent powerful computers and simulation technique enable numerical analyses to predict realistic behaviors of thermo-fluid flow, structure and do on. The present report describes resent simulation results of complex gas-liquid two-phase flow, large scale structure dynamics and fluid-structure interaction. (author)
2008-06-01
Nuclear analytical techniques in Cuban sugar industry
Energy Technology Data Exchange (ETDEWEB)
This paper is a review concerning the application of Nuclear Analytical Techniques in the Cuban sugar industry. The most complete elemental composition of final molasses (34 elements) and natural zeolites (38) this last one employed as an auxiliary agent in sugar technological processe4s has been performed by means of instrumental Neutron Activation Analysis (INAA) and X-Ray Fluorescence Analysis (XRFA). The trace elemental sugar cane soill-plant relationship and elemental composition of different types of Cuban sugar (raw, blanco-directo and refine) were also studied. As a result, valuable information referred to the possibilities of using these products in animal and human foodstuff so as in the other applications are given. (author). 34 refs., 6 figs., 1 tab.
1997-12-01
New remote sensing techniques for the detection and quantification of earth surface CO2 degassing
British Library Electronic Table of Contents (United Kingdom)
Earth degassing specifically of carbon dioxide CO2 is of increasing interest with respect to the global carbon budget, related climate effects, earthquake and volcano eruption mechanisms, as well as plant physiological reactions in gas-rich environments. Investigations in all of these disciplines require the detection of surface CO2 degassing structures and quantification of their emissions. We introduce minimal thermal change detection based on infrared imaging as a new remote sensing tool for the detection of earth surface thermal anomalies suiting among others to discover earth degassing locations of any origin. The method allows for seamless areal search and monitoring of degassing structures in any terrain. As proof of concept infrared imaging measurements were performed at the Bossol...
2008-01-01
Modelling of two-phase natural circulation in a WWER-plant: PMK experimental results
International Nuclear Information System (INIS)
Experiments have been performed with the PMK integral-type facility, a model of WWER-440 type PWRs, to investigate two-phase natural circulation behaviour. The phenomena to be expected in this reactor type are different from those in PWRs with vertical steam generators mainly due to the loop seal in the hot leg and the horizontal layout of the steam generator heat transfer tubes. The experiments showed that the system is repressurized when the water level drops to the hot leg elevation due to the effect of the loop seal. Opening of the loop seal can be smooth, but may lead to oscillations depending on the power and the mass inventory. Natural circulation recovers after the hot leg loop seal is opened, but then decreases with further mass inventory decrease. (orig.).
Liquid metal reactor cover gas purification and analysis in the USA
International Nuclear Information System (INIS)
Two sodium cooled reactors are currently being operated in the United States of America for the US Department of Energy. These are Experimental Breeder Reactor 11, EBR-11, and the Fast Flux Test Facility, FFTF. EBR-11 is located near Idaho Falls, Idaho, and the FFTF is near Richland, Washington. These reactors are currently engaged in a wide range of testing including fuels and materials tests, and plant system performance and safety development. The US DOE program also includes designs of a next generation sodium cooled power reactor. The FFTF and EBR-11 communities are providing input to these designs. This paper discusses the efforts to develop and operate cover gas systems for the sodium cooled nuclear reactor program in the USA.
1986-09-24
Influence of O{sub 2} and N{sub 2}H{sub 4} on the ECP in high temperature water
Energy Technology Data Exchange (ETDEWEB)
The ECP of construction materials in the water steam circuits of power plants is influenced by many parameters, including: reactions of oxidants, such as O{sub 2} or dissolved copper species; and reactions of reducing species, namely N{sub 2}H{sub 4}. Electrochemical measurements were performed to clarify the role of hydrazine for the open circuit potential in water/steam circuits. Current density electrode potential curves of the electrochemical oxidation of hydrazine and the reduction of oxygen in aqueous solutions were measured as a function of temperature in the range from room temperature to approximately 260{degrees}C. The electrode materials used were platinum, gold and Alloy 800 mod.. In addition, corrosion potentials were measured in water containing oxygen or hydrazine.
1992-12-31
Five years operating experience at the Fast Flux Test Facility
Energy Technology Data Exchange (ETDEWEB)
The Fast Flux Test Facility (FFTF) is a 400 Mw(t), loop-type, sodium-cooled, fast neutron reactor. It is operated by the Westinghouse Hanford Company for the United States Department of Energy at Richland, Washington. The FFTF is a multipurpose test reactor used to irradiate fuels and materials for programs such as Liquid Metal Reactor (LMR) research, fusion research, space power systems, isotope production and international research. FFTF is also used for testing concepts to be used in Advanced Reactors which will be designed to maximize passive safety features and not require complex shutdown systems to assure safe shutdown and heat removal. The FFTF also provides experience in the operation and maintenance of a reactor having prototypic components and systems typical of large LMR (LMFBR) power plants. The 5 year operational performance of the FFTF reactor is discussed in this report. 6 refs., 10 figs., 2 tabs.
1987-04-01
Five years operating experience at the Fast Flux Test Facility
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a 400 Mw(t), loop-type, sodium-cooled, fast neutron reactor. It is operated by the Westinghouse Hanford Company for the United States Department of Energy at Richland, Washington. The FFTF is a multipurpose test reactor used to irradiate fuels and materials for programs such as Liquid Metal Reactor (LMR) research, fusion research, space power systems, isotope production and international research. FFTF is also used for testing concepts to be used in Advanced Reactors which will be designed to maximize passive safety features and not require complex shutdown systems to assure safe shutdown and heat removal. The FFTF also provides experience in the operation and maintenance of a reactor having prototypic components and systems typical of large LMR (LMFBR) power plants. The 5 year operational performance of the FFTF reactor is discussed in this report. 6 refs., 10 figs., 2 tabs.
1987-09-13
Fault diagnosis on bottle filling plant using genetic-based neural network
British Library Electronic Table of Contents (United Kingdom)
Timely detection of the pneumatic system problems is important in industry. Many techniques have been employed to solve this problem. In this paper, Genetic Algorithm (GA) based optimal configuration of neural networks is proposed for fault diagnostic of bottle filling systems. Back-propagation is used for neural networks algorithm. The back-propagation algorithm had six inputs and one output. A fitness function was designed to the minimize execution time of ANN model by keeping the number of hidden layer(s) and nodes as low as possible while the mean square error of estimated output error is minimized. The designed GA-ANN combination and the graphical user interface (GUI) eliminate the trial and error process for selection of the fastest and most accurate configuration. The performance of...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Recently it is strongly required to reduce energy consumption to cope with the global warming. Since energy consumption in commercial and residential sectors are increasing while industrial sector is almost constant in Japan, policies to lead energy conservation in urban areas is quite important. This study aims at investigating the performance of urban energy systems which install combined heat and power (CHP) as a district heating and cooling (DHC) plant and the influence of CHP on the structure of electric power systems of utilities. The behavior of energy technologies and the possibility of energy conservation are evaluated based on an optimization model with respect to total system cost. Sensitivity analysis of population allocation into urban areas indicates that fossil fuel consumption varies in the range of 10--20% compared with conventional systems.
1997-12-31
Effect of thermal cycling on the alloy 800/2.25 Cr-1 Mo steel joint
International Nuclear Information System (INIS)
The critical part of the trimetallic transition joint (type 304 stainless steel/Alloy 800/2.25 Cr-1 Mo steel), the Alloy 800/2.25 Cr-1 Mo steel joint welded with Inconel 182, was subjected to thermal cycling between room temperature and 873 K. The thermal cycling test procedure used produces accelerated failures in transition joints similar to those observed in steam generators of operating power plants. On thermal cycling, precipitation at the weld/ferritic steel interface decreased on post-weld heat treatment. This precipitation increased with increased prior ageing and applied stress. The results of these tests indicated a considerable improvement in performance of the trimetallic transition joint compared to the direct (bimetallic) transition joint. (orig.).
Energy Technology Data Exchange (ETDEWEB)
The report identifies and analyzes the economic impacts of water pollution control regulations on the battery manufacturing industry. These regulations include effluent limitations and standards based on BPT (best practical control technology currently available), BAT (best available technology economically achievable), PSES (pretreatment standards existing sources), NSPS (new source performance standards), and PSNS (pretreatment standards new sources), that have been promulgated under authority of Sections 301, 304, 306, 307, 308, and 501 of the Federal Water Pollution Control Act, as Amended (the Clean Water Act). The primary economic impact variables of interest include price changes, plant closures, substitution effects, changes in employment, shifts in the balance of foreign trade, changes in industry profitability, structure, and competition, and impacts on small business.
1984-01-01
Device for controlling feedwater at low power of nuclear power plants
International Nuclear Information System (INIS)
Purpose: To provide a feedwater control device capable of minimizing the adverse response of steam drum level at low power. Consitution: In order to perform feedwater control at low power by the substantial control of three factors, that is, main steam flow rate, feedwater flow rate and steam drum level, the main steam flow rate is determined from the reactor output and feedwater rate is determined from the changes in the feedwater temperature due to the mixing of waters in the reactor clean up system and feedwater. If a difference is resulted between these flow rates, a starting feedwater regulator is controlled instantly to eliminate the difference. The water level in the steam drum is used for amending the difference from the final set value of the drum water level, by which the adverse response of the steam drum level can be minimized. (Seki, T.).
Development of ultrafiltration and adsorbents: October 1979-March 1980
Energy Technology Data Exchange (ETDEWEB)
Tests on a sample of trench water from the Maxey Flats burial ground effectively demonstrated the new Reverse Osmosis Pilot Plant. The effluent from the 50% salt-rejection membrane was decontaminated well enough with the exception of tritium to be discharged to the environment. The performance of the 97% salt-rejection membrane was superior to that of the 50% membrane. A breakthrough and capacity experiment was conducted with Durasil 10 on a simulated Three Mile Island solution. The maximum decontamination factor was extrapolated to be 10/sup 6/, which would reduce the cesium level of TMI water to below the discard limit. Capacity (1/DF = 0.5) was reached at 1260 column volumes. Several adsorbents were tested in the engineering columns for decontamination of cesium-bearing solutions. Under the conditions of the experiment, these adsorbents were ineffective in removing cesium from the solution.
1980-07-02
British Library Electronic Table of Contents (United Kingdom)
A dry interim storage facility has been constructed at the Wolsung power plant in Korea. This dry storage facility has seven separated modules. There are 40 long slender cylinders in one module. In one cylinder, ten baskets where sixty CANDU spent fuel bundles are loaded are stacked and stored. For this dry storage facility, analyses and tests for hypothetical accident conditions that might occur while moving and storing the baskets into a cylinder were performed. In a demonstration test, one of test basket models did not satisfy one of the safety-related requirements. Thus, the revised basket designs were generated using a structural evaluation based on finite element analyses and specimen tests. Among these revised designs, one design was chosen as a final revised basket design. The fina...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Cost-time management methods have been developed by Westinghouse to examine business applications from a cost-time perspective. The initial application of cost-time management within Westinghouse was targeted at reducing cycle time in the manufacturing sector. As a result of the tremendous success of reduced cycle time in manufacturing, Westinghouse initiated application of the management technique to Environmental Restoration activities at its Government Owned Contractor Operated facilities. The Westinghouse initiative was proposed in support of the Department of Energy`s goals for cost effective Environmental Restoration activities. This paper describes the application of the cost-time method to Environmental Restoration work currently being performed at the Idaho National Engineering Laboratory (INEL) for the Department of Energy (DOE) by Westinghouse Idaho Nuclear Company (WINCO).
1992-05-22
International Nuclear Information System (INIS)
Cost-time management methods have been developed by Westinghouse to examine business applications from a cost-time perspective. The initial application of cost-time management within Westinghouse was targeted at reducing cycle time in the manufacturing sector. As a result of the tremendous success of reduced cycle time in manufacturing, Westinghouse initiated application of the management technique to Environmental Restoration activities at its Government Owned Contractor Operated facilities. The Westinghouse initiative was proposed in support of the Department of Energy's goals for cost effective Environmental Restoration activities. This paper describes the application of the cost-time method to Environmental Restoration work currently being performed at the Idaho National Engineering Laboratory (INEL) for the Department of Energy (DOE) by Westinghouse Idaho Nuclear Company (WINCO).
1992-08-23
Energy Technology Data Exchange (ETDEWEB)
This project seeks to produce sufficient information on the physical and chemical nature of Coolside waste to design and construct physically stable and environmentally safe landfills. Unconfined compressive strength and permeability tests are reported on samples remolded near 90, 95, and 100% of low energy, standard, and modified dry densities. Unconfined compressive strength tests were also performed on some of the samples after permeability tests were completed. Swell tests were initiated on samples from Coolside pilot plant run {number_sign}2 and on a FBC hydrated ash remolded near 95% of standard density and optimum moisture content.
1993-11-01
Changes in DNA content during rhizobial nodule development in Lupinus luteus L. 1
International Nuclear Information System (INIS)
Cytophotometric measurements of DNA content after Feulgen's reaction and autoradiography after incubation with "3H-thymidine were performed to investigate the early stages of development of yellow lupin root nodule. The first response of the host plant to the contact with Rhizobium lupini was the enhancement of nuclear DNA endoreplication in root cortex cells. A conversion of the initially mixoploid nodule meristem into a diploid one during root nodule formation was found. Differentiation of bacteroid-containing tissue both from diploid and polyploid cells was observed. The highest content of nuclear DNA in the uninfected root cortex, nodule cortex and in bacteroid-containing tissue was 16 C. (author).
1989-01-01
Catalytic applications of red mud, an aluminium industry waste. A review
Energy Technology Data Exchange (ETDEWEB)
Red mud is a by-product of bauxite processing through Bayer process. The amount of red mud generated depends largely on the type of ore used and the processing. Use of red mud as a catalyst can be a good alternative to the existing commercial catalysts. Its properties such as iron content in form of ferric oxide (Fe{sub 2}O{sub 3}), high surface area, sintering resistance, resistance to poisoning and low cost make it an attractive potential catalyst for many reactions. Besides red mud, ferric ion sludge from wastewater treatment plant has also been studied for its catalytic properties, mainly due to its ferric oxide constituent. This paper reviews the studies on red mud as a catalyst. The catalyst characteristics, reaction mechanisms involved and performance are examined and compared with iron oxide catalyst and commercial catalysts. (author)
2008-05-30
Energy Technology Data Exchange (ETDEWEB)
The need to increase efficiency of volumetric receivers for use in solar power plants by reducing reradiation losses and increasing the ``volumetric effect`` has promoted the idea of a receiver with tapered ducts. These seems to be very promising since higher efficiency and considerable saving of material can be achieved, as compared to conventional receivers perforated with ducts of constant cross-section. A finite element program is being developed to calculate stationary heat transfer in the tapered ducts by free and forced convection in the gas flow, conduction in walls and in the gas, and solar and thermal radiation. Gas and wall temperatures are considered to be varying only in the flow direction. In order to perform the highly nonlinear calculations of radiative exchange, the exact knowledge of the view factors is necessary. The aim of the present work is to evaluate analytically the view factors in tapered ducts.
1995-02-01
CO2 CAPTURE BY ABSORPTION WITH POTASSIUM CARBONATE
Energy Technology Data Exchange (ETDEWEB)
The objective of this work is to improve the process for CO{sub 2} capture by alkanolamine absorption/stripping by developing an alternative solvent, aqueous K{sub 2}CO{sub 3} promoted by piperazine. CO{sub 2} mass transfer rates are second order in piperazine concentration and increase with ionic strength. Modeling of stripper performance suggests that 5 m K{sup +}/2.5 m PZ will require 25 to 46% less heat than 7 m MEA. The first pilot plant campaign was completed on June 24. The CO{sub 2} penetration through the absorber with 20 feet of Flexipac{trademark} 1Y varied from 0.6 to 16% as the inlet CO{sub 2} varied from 3 to 12% CO{sub 2} and the gas rate varied from 0.5 to 3 kg/m{sup 2}-s.
2004-07-29
Application of an inverse input/output mapped ANN as a power system stabilizer
Energy Technology Data Exchange (ETDEWEB)
An artificial neural network (ANN), trained as an inverse of the controlled plant, to function as a power system stabilizer (PSS) is presented in this paper. In order to make the proposed ANN PSS work properly, it was trained over the full working range of the generating unit with a large variety of disturbances. Data used to train the ANN PSS consists of the control input and the synchronous machine response with an adaptive PSS (APSS) controlling the generator. During training, the ANN was required to memorize the reverse input/output mapping of the synchronous machine. After the training, the output of the synchronous machine was applied as the input of the ANN PSS and the output of the ANN PSS was used as the control signal. Simulation results show that the proposed ANN PSS can provide good damping of the power system over a wide operating range and significantly improve the system performance.
1994-09-01
British Library Electronic Table of Contents (United Kingdom)
To estimate the success criteria of an operators action time for a probabilistic safety/risk assessment (PSA/PRA) of a nuclear power plant, the information from a safety analysis report (SAR) and/or that by using a simplified simulation code such as the MAAP code has been used in a conventional PSA. However, the information from these is often too conservative to perform a realistic PSA for a risk-informed application. To reduce the undue conservatism, the use of a best-estimate thermal hydraulic code has become an essential issue in the latest PSA and it is now recognized as a suitable tool. In the same context, the `ASME PRA standard' also recommends the use of a best-estimate code to improve the quality of a PSA. In Korea, a platform to use a best-estimate thermal hydraulic code called ...
2007-01-01
Acid mine water treatment in wetlands: an overview of an emergent technology
Energy Technology Data Exchange (ETDEWEB)
Experimental wetlands are being constructed on mined lands in the United States as an inexpensive alternative to conventional acid mine water treatment facilities. The US Bureau of Mines is conducting an inventory of these constructed wetlands as part of a long-term evaluative study. Preliminary results, based on the 20 sites surveyed to date, indicate that the wetlands dominated by emergent species are out-performing the Sphagnum-dominated wetlands, and that much of the water treatment is accomplished by other aspects of the wetland, including bacteria, algae, amendments and other plants. Iron concentrations as high as 85 mg/l are reduced to less than 3 mg/l after flow through the constructed wetlands. Manganese is also removed, though somewhat less efficiently. 12 refs., 1 fig., 1 tab.
1987-12-31
Abundance response of western European forest species along canopy openness and soil pH gradients
British Library Electronic Table of Contents (United Kingdom)
In order to better understand the structure and composition of forest plant communities, we aimed to predict the abundance of understory herbaceous species locally at the stand level and according to different environments. For this, we seeked to model species distributions of abundance at a regional scale in relationship with the local stand structure (canopy openness) and regional soil resources (soil pH). Floristic inventories, performed in different light and soil conditions located in 1202 records of north eastern France, were used to analyze the combined effect of canopy openness and soil pH on the abundance of 12 common western European forest species: Anemone nemorosa, Deschampsia flexuosa, Festuca altissima, Hedera helix, Lamium galeobdolon, Lonicera periclymenum, Molinia caerulea...
2011-01-01
ARIES-AT safety design and analysis
British Library Electronic Table of Contents (United Kingdom)
ARIES-AT is a 1000MWe conceptual fusion power plant design with a very low projected cost of electricity. The design contains many innovative features to improve both the physics and engineering performance of the system. From the safety and environmental perspective, there is greater depth to the overall analysis than in past ARIES studies. For ARIES-AT, the overall spectrum of off-normal events to be examined has been broadened. They include conventional loss of coolant and loss of flow events, an ex-vessel loss of coolant, and in-vessel off-normal events that mobilize in-vessel inventories (e.g., tritium and tokamak dust) and bypass primary confinement such as a loss of vacuum and an in-vessel loss of coolant with bypass. This broader examination of accidents improves the robustness of ...
2006-01-01
A vortex valve ejector combination for fluidic two diode pumps
International Nuclear Information System (INIS)
Fluidic two diode pumps have been developed for moving highly toxic and for radioactive waste liquors about chemical plant. The pumps have a cylinder into which liquor is initially sucked and then expelled. For situations where no maintenance can be carried out the need has arisen for a fluidic alternator to the solenoid ejector system used on top of the pump cylinder to supply an alternating negative/positive air supply. A fluidic air alternator has been constructed by modifying a small vortex amplifier and inserting an ejector opposite to the throat of the outlet diffuser. The vortex valve ejector is described and performance characteristics are presented. Several developments of the V.V.E. for fluidic pumping and other applications are also reported. (author).
A study on the transient analysis of pipe and restraint due to impact loading
Energy Technology Data Exchange (ETDEWEB)
In this study, experiments were performed for pipe whip phenomena simulation. The analytical method was developed by combining several kinds of elements in ABAQUS computer code, standard version 5.2 . The transient analytical and the experimental results of the pipe whip test using 6 inch diameter pipe and U-shaped restraints are presented. It is shown that the adequate clearance decreases the restraint strains. As the overhang length increased, the maximum strain of restraints decreased. When the impact force increased, the maximum restraint strain increased slightly. The analytical models simulate the experimental impact phenomena very precisely, with slight conservatism. It is verified that the analytical method developed is very suitable to pipe whip phenomena analysis in nuclear power plants. 6 refs., 10 figs., 1 tab.
1995-12-31
Energy Technology Data Exchange (ETDEWEB)
A controlled field pilot has been developed in Bozeman, Montana, USA, to study near surface CO2 transport and detection technologies. A slotted horizontal well divided into six zones was installed in the shallow subsurface. The scale and CO2 release rates were chosen to be relevant to developing monitoring strategies for geological carbon storage. The field site was characterized before injection, and CO2 transport and concentrations in saturated soil and the vadose zone were modeled. Controlled releases of CO2 from the horizontal well were performed in the summers of 2007 and 2008, and collaborators from six national labs, three universities, and the U.S. Geological Survey investigated movement of CO2 through the soil, water, plants, and air with a wide range of near surface detection techniques. An overview of these results will be presented.
2009-10-20
Energy Technology Data Exchange (ETDEWEB)
In recent years, interest in the development of a polymer electrolyte fuel cell (PEFC) has considerably increased due to its advantages (e.g., high power density) compared with other fuel cell systems, and its potentials to become the power plant for the next generation, nonpolluting automobile engine. For large scale application of fuel cells, low platinum loading electrode structures are necessary. An electrode based on a highly porous carbonized polyacrylonitrile foam material with very low platinum loading ({approximately} 13 {micro}g/cm{sup 2}) was prepared. The performance of this electrode for oxygen reduction was evaluated and compared with bulk platinum and glassy carbon electrodes.
1996-01-01
The vigilance reinforcement hypothesis (VRH) asserts that errors in signal detection tasks are partially explained by operant reinforcement and extinction processes. VRH predictions were tested with a computerized baggage screening task. Our experiment evaluated the effects of signal schedule (extinction vs. variable interval 6 min) and visual field complexity (dial vs. baggage x-ray) on search behavior rates. There was a main effect for signal schedule [F (1, 20) = 14.0, p = 0.001, p[subscript rep] = 0.99], but no effects for field complexity or interaction. The VRH suggests that performance errors in visual screening work may be reduced through operant conditioning of search behaviors by intensive management of artificially planted signals. (Contains 1 table and 3 figures.)
2008-12-01
A Detailed Investigation on Human-Related Unplanned Reactor Trip Events in Korea
International Nuclear Information System (INIS)
Human errors have been reported as one of the most significant causes of major events in nuclear power plants (NPPs). For example, Kim and Park found that about 23% of the major events that occurred at NPPs in Republic of Korea from 1986 to 2006 were caused by human errors. For this reason, a detailed analysis on human errors is an important task for increasing the safety of NPPs. Kim and Choi?2 analyzed 100 human-related unplanned reactor trip events in the Republic of Korea from 1986 to 2006 to consider the type of human errors based on the simple path model for human-induced unplanned reactor trips developed by Kim and Park. In this paper, we will investigate and perform a detailed analysis of the data to identify human-related unplanned reactor trip trends
2010-10-01
Energy Technology Data Exchange (ETDEWEB)
The following subjects were discussed at the conference: Stability of welded joints, creep stress in CrMo steels, life prediction, developments in modern power plant steels, testing, calculation of deformation, crack propagation and crack analysis under complex loads. [German] Die Autoren der Tagung referieren ueber folgende Themen: Stabilitaet von Schweissverbindungen, Kriechbeanspruchung von Chrom-Molybdaen Staehlen, Lebensdauervorhersage, Entwicklungen fuer die Anwendung in modernen Kraftwerken, Prueftechnik, Berechnung von Verformung, Rissentwicklung und -bewertung bei komplexer Beanspruchung. (uke)
2002-07-01
Energy Technology Data Exchange (ETDEWEB)
The development and improvement of materials plays a key role in energy technology, particularly in power plant technology, because materials are crucial to plant performance and power availability. This becomes particularly clear when one considers that modern power plants generate temperatures of up to 600 C and pressures of up to 230 bar in order to increase process efficiency, conserve resources and reduce CO{sub 2} emissions. Modern heat-resistant materials for power plant technology are customised materials which have been developed to meet the specific requirements of special applications. After the requirement profile has been determined the material is developed or optimised on the basis of previous experiences gained with materials in power plant technology. Basic heat-resistant materials are ferritic materials containing 9 to 12% Cr as well as ...
2000-07-01
Energy Technology Data Exchange (ETDEWEB)
Using an economic perspective, it is possible to make a case for green buildings and green development practices by placing emphasis on Energy Efficiency and Environmental Design. Several case studies have demonstrated that green buildings save money through reduced consumption of natural resources, electricity and gas both at the building site and at the source of energy. Sound environmental practices and energy efficiency measures improve the environmental conditions throughout the state by reducing power plant emissions and reducing operations and maintenance budgets in the state. The author presented a case study where a green development project was guided and monitored using the Environmental Performance Rating System called Leadership in Energy and Environmental Design (LEED), version 2.0. The work was registered to achieve LEED certification. A brief study on current construction related costs was also included. 2 refs., 1 fig.
2003-07-01
The Vortec Cyclone Melting System (CMS) facility; to be located at the U.S. Department of Energy (DOE) Paducah Gaseous Diffusion Plant, is designed to treat soil contaminated with low levels of heavy metals and radioactive elements, as well as organic waste. The primary components of Vortec`s CMS are a counter rotating vortex (CRV) reactor and cyclone melter. In the CMS process, granular glass forming ingredients and other feedstocks are introduced into the CRV reactor where the intense CRV mixing allows the mixture to achieve a stable reaction and rapid heating of the feedstock materials. Organic contaminants in the feedstock are effectively oxidized, and the inert inorganic solids are melted. The University of North Dakota Energy {ampersand} Environmental Research Center (EERC) has been contacted to help in the development of sampling plans and to conduct the sampling at the facility. This document is written in a format that assumes that the EERC will ...
1997-12-31
International Nuclear Information System (INIS)
Computer based control systems for safety related applications in nuclear power plants have to meet not only the functional, performance and interface requirements, they in addition, have to meet regulatory requirements like enhanced reliability, safety and security and should provide fault tolerance, diagnostics and self-supervision. The control system architecture, hardware design and software design should meet requirements as specified in design code and guides of AERB. The Dual Processor Hot Standby Process Control System (DPHS-PCS) for TAPP-3 and 4 is a safety related (Class- IB) system. DPHS-PCS regulates PHT pressure, Pressuriser pressure, Pressuriser level, Bleed condenser pressure, Bleed condenser level and Steam generator pressure. The performance, reliability and safety requirements of this control system are met by employing a fault tolerant computer configuration developed for this purpose using hardware ...
2005-03-01
Real-time 3-D SAFT-UT system evaluation and validation
International Nuclear Information System (INIS)
SAFT-UT technology is shown to provide significant enhancements to the inspection of materials used in US nuclear power plants. This report provides guidelines for the implementation of SAFT-UT technology and shows the results from its application. An overview of the development of SAFT-UT is provided so that the reader may become familiar with the technology. Then the basic fundamentals are presented with an extensive list of references. A comprehensive operating procedure, which is used in conjunction with the SAFT-UT field system developed by Pacific Northwest Laboratory (PNL), provides the recipe for both SAFT data acquisition and analysis. The specification for the hardware implementation is provided for the SAFT-UT system along with a description of the subsequent developments and improvements. One development of technical interest is the SAFT real time processor. Performance of the real-time processor is impressive and comparison is made ...
1993-05-17
Radiation processing in Hungary
Energy Technology Data Exchange (ETDEWEB)
Hungary has 10.7 million population in 100,000 km/sup 2/ territory. The gross national product is about $3,000 per capita per year. Hungary is a country with highly developed agriculture and medium degree developed industries. The Hungarian economy is an open economy because more than 40% of the national income is earned by export. The research and development works on various radiation processing have been performed for 25 years. In the Central Research Institute for Physics of the Hungarian Academy of Sciences, a laboratory was organized for the basic research of radiation chemistry and the moderator materials for nuclear reactors. Also the activities in the Central Research Institute for Chemistry, the Institute of Isotopes, the Research Institute for Plastics Industry, and the Central Research Institute for Food Industry are briefly reported. The largest radiation processing unit in Hungary is the automatic sterilization plant of Medicor ...
1982-01-01
Energy Technology Data Exchange (ETDEWEB)
Safety and environmental assessments have been made of conceptual fusion power plant designs employing silicon carbide composites (SiC/SiC) as the first wall and blanket structure material. These have used similar analysis methods to earlier studies of designs based on vanadium alloy or low-activation martensitic steel, allowing direct comparisons. The very low short-term activation of silicon carbide results in an almost insignificant level of decay heat in postulated loss of coolant accidents, and a lower {gamma}-dose rate on the timescale of relevance to handling for maintenance operations. However on the longer time-scale, of interest in possible recycling operations, decommissioning and waste management, SiC/SiC appears to perform no better than vanadium alloy or low-activation martensitic steel, due in part to the activation of impurities in a realistic composition. Furthermore, its increased neutron transparency may result in higher ...
2001-04-01
Monitoring of power generation from landfill gas at Cory Environmental Ltd., Mucking Marshes
Energy Technology Data Exchange (ETDEWEB)
The energy recovery scheme at Mucking Marshes landfill site, operated by Cory Environmental Limited, has been in operation since October 1991. Using landfill gas abstracted from the site, a gas turbine generates up to 3.2 MW net electric power for export. Operation and performance of the scheme has been monitored over the period January 1995 to August 1996. Overall performance since the first use of the turbine has also been studied, and has shown reliable and profitable operation. The capital cost of the gas turbine and gas compressor plant was approximately 1.8 million. Actual gas collection wells, pipework, pumping and monitoring facilities, while essential to the scheme, are considered part of the gas control equipment needed for the landfill site. Based on a notional electricity selling price of 4p/kWh, the current annual income from exported power is 550,000. This would be substantially increased by increasing the ...
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
The primary objective of the project is to investigate the long-term effects of commercially available tangentially-fired low NO{sub x} combustion technologies on NOx emissions and boiler performance on Unit 2 at Gulf Power Company`s Plant Lansing Smith located near Lynn Haven, Florida. The project will characterize emissions and performance of a tangentially-fired boiler operating in the following configurations: Baseline ``as-found`` configuration: Phase 1; retrofitted low NO{sub x} concentric firing system (LNCFS) Level 2 and simulated low NO{sub x} bulk furnace staging (LNBFS): Phase 2; retrofitted low NO{sub x} concentric firing system (LNCFS) Level 3, Phase 3a and simulated LNCFS Level 1, Phase 3b.
1992-01-01
Energy Technology Data Exchange (ETDEWEB)
The primary objective of the project is to investigate the long-term effects of commercially available tangentially-fired low NO{sub x} combustion technologies on NOx emissions and boiler performance on Unit 2 at Gulf Power Company's Plant Lansing Smith located near Lynn Haven, Florida. The project will characterize emissions and performance of a tangentially-fired boiler operating in the following configurations: Baseline as-found'' configuration: Phase 1; retrofitted low NO{sub x} concentric firing system (LNCFS) Level 2 and simulated low NO{sub x} bulk furnace staging (LNBFS): Phase 2; retrofitted low NO{sub x} concentric firing system (LNCFS) Level 3, Phase 3a and simulated LNCFS Level 1, Phase 3b.
1992-01-01
Graphite Technology Development Plan
Energy Technology Data Exchange (ETDEWEB)
This technology development plan is designed to provide a clear understanding of the research and development direction necessary for the qualification of nuclear grade graphite for use within the Next Generation Nuclear Plant (NGNP) reactor. The NGNP will be a helium gas cooled Very High Temperature Reactor (VHTR) with a large graphite core. Graphite physically contains the fuel and comprises the majority of the core volume. Considerable effort will be required to ensure that the graphite performance is not compromised during operation. Based upon the perceived requirements the major data needs are outlined and justified from the perspective of reactor design, reatcor performance, or the reactor safety case. The path forward for technology development can then be easily determined for each data need. How the data will be obtained and the inter-relationships between the experimental and modeling activities will define the ...
2007-09-01
Geometry optimization of Fresnel-collectors with economic assessment
Energy Technology Data Exchange (ETDEWEB)
The Fresnel solar collector is a promising concept to reduce the electricity cost price in solar thermal power plants. The optical performance of a Fresnel collector depends on material properties, on its geometric layout and on the level of optical accuracy that can be obtained. A variety of geometric parameters, e.g. the height of the absorber, the number, size and distance of primary mirrors in.uence the shading and blocking of rays and the amount of rays missing the absorber. To evaluate the in.uence of the parameter variation regarding the electricity cost price and to yield an optimization, the optical performance is assessed with an annual simulation based on hourly weather-data. To permit a consideration of changes in collector cost according to different geometric layouts, cost factors where allocated to geometric parameters. The paper presents the method and the simulation results of the optimization under ...
2004-07-01
Gasification of lignocellulosic biomass in fluidized beds for renewable energy development: A review
Energy Technology Data Exchange (ETDEWEB)
A literature review on gasification of lignocellulosic biomass in various types of fluidized bed gasifiers is presented. The effect of several process parameters such as catalytic bed material, bed temperature and gasifying agent on the performance of the gasifier and quality of the producer gas is discussed. Based on the priorities of researchers, the optimum values of various desired outputs in the gasification process including improved producer gas composition, enhanced LHV, less tar and char content, high gas yield and enhanced carbon conversion and cold gas efficiency have been reported. The characteristics and performance of different fluidized bed gasifiers were assessed and the obtained results from the literature have been extensively reviewed. Survey of literature revealed that several industrial biomass gasification plants using fluidized beds are currently conducting in various countries. However, more research ...
2010-12-15
Four-inch pipe whip test under BWR LOCA conditions effect of overhang length
Energy Technology Data Exchange (ETDEWEB)
Pipe whip tests or jet discharge tests have been performed at the Japan Atomic Energy Research Institute, which simulate the instantaneous guillotine break of primary coolant piping in nuclear power plants. This paper describes the results of the 4-inch pipe whip tests(RUN 5407, 5501, 5504, 5603), under the BWR LOCA conditions, which were performed from 1979 to 1981. The test pressure was 6.8 MPa and test temperature 285/sup 0/C. In these tests, clearance was kept constant at the value of 100 mm and overhang lengths were 250, 400, 550 and 1,000 mm, respectively. The main purpose of these tests is to investigate the effect of overhang length on pipe whip behavior. From the tests results, the pipe movement is effectively limited by the restraints if the overhang length is 250 mm or 400 mm. The deformation of the test pipe and restraints becomes large with increasing overhang length. It is clarified that the test pipe ...
1983-03-01
International Nuclear Information System (INIS)
The Melt Vessel Interaction (MVI) project is concerned with the consequences of the interactions that a core melt, generated during a postulated severe accident in a light water reactor, may have with the pressure vessel. In particular, the issues concerned with the failure of the vessel bottom head are the focus of the research. The specific objectives of the project are to obtain data and develop validated models, which could be applied to prototypic plants, and accident conditions, for resolution of issues related to the melt vessel interactions. The project work has been performed by nine partners having varied responsibility. The work included a large number of experiments, with simulant materials, whose observations and results are employed, respectively, to understand the physical mechanisms and to develop validated models. Applications to the prototypic geometry and conditions have also been performed. This report ...
1995-10-01
Ensuring the 50 year life of a fissile material container
Energy Technology Data Exchange (ETDEWEB)
Sandia was presented with an opportunity in 1993 to design containers for the long term storage and transport of fissile material. This program was undertaken at the direction of the US Department of Energy and in cooperation with Lawrence Livermore National Laboratory and Los Alamos National Laboratory which were tasked with developing the internal fixturing for the contents. The hardware is being supplied by Allied Signal Federal Manufacturing and Technologies, and the packaging will occur at Mason and Hangar Corporation`s Pantex Plant. The unique challenge was to design a container that could be sealed with the fissile material contents; and, anytime during the next 50 years, the container could be transported with only the need for the pre-shipment leak test. This required not only a rigorous design capable of meeting the long term storage and transportation requirements, but also resulted in development of a surveillance program to ensure that the container ...
1997-12-01
Effective multiplication factor measurement by feynman-{alpha} method. 3
Energy Technology Data Exchange (ETDEWEB)
The sub-criticality monitoring system has been developed for criticality safety control in nuclear fuel handling plants. In the past experiments performed with the Deuterium Critical Assembly (DCA), it was confirmed that the detection of sub-criticality was possible to k{sub eff} = 0.3. To investigate the applicability of the method to more generalized system, experiments were performed in the light-water-moderated system of the modified DCA core. From these experiments, it was confirmed that the prompt decay constant ({alpha}), which was a index of the sub-criticality, was detected between k{sub eff} = 0.623 and k{sub eff} = 0.870 and the difference of 0.05 - 0.1{Delta}k could be distinguished. The {alpha} values were numerically calculated with 2D transport code TWODANT and monte carlo code KENO V.a, and the results were compared with the measured values. The differences between calculated and measured values were proved ...
1998-06-01
Economic analysis of fuel recycle
International Nuclear Information System (INIS)
Economic analysis was performed at KAERI with the assistance of US DOE to compare single reactor fuel cycle costs for a once-through option and a thermal recycle option to operate 1 GWe of a PWR plant for its lifetime. A reference fuel cycle cost was first calculated for each option with best estimated reference input data. Then a sensitivity analysis was performed changing each single value of such fuel cycle component costs as yellow cake price, enrichment charges, spent fuel storage cost, reprocessing cost, spent fuel disposal cost and reprocessing waste disposal cost. Savings due to thermal recycle in requirements of uranium, conversion, and enrichment were examined using formulas suggested by US DOE, while MOX fabrication penalty was accounted for. As a result of the reference fuel cycle cost analysis, it is calculated that the thermal recycle option is marginally more economical than the once-through option. The major ...
1985-05-19
Design/build/mockup of the Waste Isolation Pilot Plant gas generation experiment glovebox
Energy Technology Data Exchange (ETDEWEB)
A glovebox was designed, fabricated, and mocked-up for the WIPP Gas Generation Experiments (GGE) being conducted at ANL-W. GGE will determine the gas generation rates from materials in contact handled transuranic waste at likely long term repository temperature and pressure conditions. Since the customer`s schedule did not permit time for performing R&D of the support systems, designing the glovebox, and fabricating the glovebox in a serial fashion, a parallel approach was undertaken. As R&D of the sampling system and other support systems was initiated, a specification was written concurrently for contracting a manufacturer to design and build the glovebox and support equipment. The contractor understood that the R&D being performed at ANL-W would add additional functional requirements to the glovebox design. Initially, the contractor had sufficient information to design the glovebox shell. Once the shell design was approved, ANL-W ...
1996-10-01
Crud removal performance with ion exchange resins in BWR plants
Energy Technology Data Exchange (ETDEWEB)
It is needless to say that one of the most important roles of the condensate demineralizer in Japanese boiling water reactors (BWR) is to eliminate such impurities during accidental occurrence of sea water leakage from condensate cooling system. Ion exchange resins packed in condensate demineralizer have also been expected to decrease crud, or corrosion products (CP) in condensate water in order to finally reduce activated corrosion products (ACP) in the reactor coolant loop. It is perceived that crud removal ability of a condensate demineralizer has been improved year by year. And we call this phenomenon as `Aging Effect`. Typical property changes of aged cation exchange resin consisted of an increase of water retention capacity and a change of surface texture. Based on these findings, we formulated a new concept and developed new gel type ion exchange resins for the better crud removal. The results from column tests using actual condensate water for approximately three years and full ...
1996-01-01
Energy Technology Data Exchange (ETDEWEB)
Increasingly, governments enact more stringent regulations governing nitrogen and phosphorus in the discharge effluent of wastewater treatment plants. Scientists know that nitrogen and phosphorus accelerates the eutrophication of lakes and reservoirs and stimulates algal growth. Ammonia has proven to be toxic to aquatic life forms, including fish. Engineers favour Biological Nutrient Removal (BNR) over chemical addition to wastewater treatment. Sequencing Batch Reactors (SBRs), a type of bioreactor requiring less land, provide the anaerobic, anoxic, and aerobic zones necessary for BNR. Methanol was used as an effective external source of carbon for denitrification but lacked research. The authors remedied this situation and some of the results were available. They indicated that the addition of methanol in the SBR increased solids production in the SBR, leading to increased sludge wasting to the aerobic digester. All aspects of the sludge digester ...
2000-07-01
CFD Application to the Regulatory Assessment of FAC-Caused CANDU Feeder Pipe Wall Thinning Issue
Energy Technology Data Exchange (ETDEWEB)
From the results of the In-Service Inspection (ISI) measuring the wall thickness of outlet (hot-leg side) feeder pipes performed at two Canadian nuclear power plants, Point Lepreau and Gentilly-2 in 1995 and 1996, respectively, the wall thinning degradation of feeder pipes at the bend part was found to be much more severe than expected. It has been well known that such wall thinning of feeder pipes is caused by the flow accelerated corrosion (FAC) which is one of the mechanical-chemical degradation mechanisms affecting the integrity of piping systems. For the Wolsung unit 1, the wall thickness measurements have been performed during every overhaul period since 1996. The wall thinning rates at the bends of outlet feeder pipes were assessed to exceed the design value. However, for the Wolsung units 2, 3 and 4, the wall thinning rates of all the outlet feeder pipes were assessed not to exceed it. The reason is because the ...
2007-07-01
CFD Application to the Regulatory Assessment of FAC-Caused CANDU Feeder Pipe Wall Thinning Issue
International Nuclear Information System (INIS)
From the results of the In-Service Inspection (ISI) measuring the wall thickness of outlet (hot-leg side) feeder pipes performed at two Canadian nuclear power plants, Point Lepreau and Gentilly-2 in 1995 and 1996, respectively, the wall thinning degradation of feeder pipes at the bend part was found to be much more severe than expected. It has been well known that such wall thinning of feeder pipes is caused by the flow accelerated corrosion (FAC) which is one of the mechanical-chemical degradation mechanisms affecting the integrity of piping systems. For the Wolsung unit 1, the wall thickness measurements have been performed during every overhaul period since 1996. The wall thinning rates at the bends of outlet feeder pipes were assessed to exceed the design value. However, for the Wolsung units 2, 3 and 4, the wall thinning rates of all the outlet feeder pipes were assessed not to exceed it. The reason is because the ...
2007-05-10
CANDU 9 - the CANDU product to meet customer and regulator requirements now and in the future
Energy Technology Data Exchange (ETDEWEB)
CANDU reactors developed under Canadian licensing regulations that placed the primary responsibility for safety on the licensee. The Atomic Energy Control Board (AECB), Canada's nuclear regulatory agency, state in their regulations what is expected in terms of safety performance so that designers are free to propose the best means of meeting this performance. This goal-oriented approach, besides encouraging innovation, allowed CANDU to be licensed in other jurisdictions. The latest design - the large, single unit, CANDU 9 - explicitly incorporates licensability in Canada through a formal AECB review of the design; lessons learned from licensing CANDU 6 in Asian countries, particularly with Wolsong 2, 3 and 4 in Korea, and more recently with Qinshan in China; utility requirements for modem evolutionary plants; and emerging international standards for safety, sponsored or issued by the IAEA. By combining the ...
1998-07-01
CANDU 9 - the CANDU product to meet customer and regulator requirements now and in the future
International Nuclear Information System (INIS)
CANDU reactors developed under Canadian licensing regulations that placed the primary responsibility for safety on the licensee. The Atomic Energy Control Board (AECB), Canada's nuclear regulatory agency, state in their regulations what is expected in terms of safety performance so that designers are free to propose the best means of meeting this performance. This goal-oriented approach, besides encouraging innovation, allowed CANDU to be licensed in other jurisdictions. The latest design - the large, single unit, CANDU 9 - explicitly incorporates licensability in Canada through a formal AECB review of the design; lessons learned from licensing CANDU 6 in Asian countries, particularly with Wolsong 2, 3 and 4 in Korea, and more recently with Qinshan in China; utility requirements for modem evolutionary plants; and emerging international standards for safety, sponsored or issued by the IAEA. By combining the assurance of ...
1998-05-03
A study of turbulent heat transfer in the subchannel by the large scale secondary vortex flow
International Nuclear Information System (INIS)
Experimental and computational studies were performed to confirm the enhancement of turbulent heat transfer performance in the 6x6 simulated rod bundle subchannel by generating the large scale secondary vortex flow. Experimental studies were carried out at Reynolds Number 10,000 with atmospheric condition. Axial variations of mean velocity and turbulent intensity in the rod bundle subchannel were measured by the 2-color LDV measurement system. Computational works were accomplished using the commercial CFD code, FLUENT. Normal operating condition of Uljin 3, 4 nuclear power plant is used in computation works as an initial condition. The LSSVF mixing vanes generate the most strong secondary flow vortices that maintain about 35 D_H after the spacer grid. The LSSVF mixing vane influences strongly to flow mixing in adjacent subchannels because large scale stream wise vortices in subchannel sustain two times more than that in ...
2002-11-17
Nuclear power plants connected with pumped storage plants by the inland lakes
International Nuclear Information System (INIS)
Finnish (May 1971). Finland Kilpelaeinen, JE Imatran Voima Osakeyhtio,
1971-01-01
Hydroelectric Power Plants Electrical Design
... Treatment of electrical systems for pumped storage plants is not covered in the manual, although much of the information is applicable to pumped ...
1994-06-30
Energy Technology Data Exchange (ETDEWEB)
The AVR experimental nuclear reactor was Professor Dr. Rudolf Schulten's brainchild. Visionary ideas led to the success of this technology: - Helium coolant because of the particularly high heat transfer coefficients; - an integrated primary system reactor concept as the basis of all safety considerations in the interest of maximum safety; - uranium-235 and thorium-232 fuel allowing new fuel to be bred; - high temperatures for electricity generation at maximum thermodynamic efficiencies, i.e. optimum fuel utilization; - the possibility to run chemical processes economically at high temperatures by means of nuclear fuels; - the inherent safety of the reactor, for a major accident accompanied by a complete loss of cooling cannot occur for nuclear physics reasons, as was tested twice in the AVR. The AVR attained its first criticality on August 28, 1968. It was operated for more than 20 years, until December 31, 1988, at approximately 67% time utilization, which is an excellent ...
2009-12-15
International Nuclear Information System (INIS)
The AVR experimental nuclear reactor was Professor Dr. Rudolf Schulten's brainchild. Visionary ideas led to the success of this technology: - Helium coolant because of the particularly high heat transfer coefficients; - an integrated primary system reactor concept as the basis of all safety considerations in the interest of maximum safety; - uranium-235 and thorium-232 fuel allowing new fuel to be bred; - high temperatures for electricity generation at maximum thermodynamic efficiencies, i.e. optimum fuel utilization; - the possibility to run chemical processes economically at high temperatures by means of nuclear fuels; - the inherent safety of the reactor, for a major accident accompanied by a complete loss of cooling cannot occur for nuclear physics reasons, as was tested twice in the AVR. The AVR attained its first criticality on August 28, 1968. It was operated for more than 20 years, until December 31, 1988, at approximately 67% time utilization, which is an excellent ...
2009-12-01
International Nuclear Information System (INIS)
Although low-energy ion radiation has been proven to have a wide range of biological effects and led to fruitful achievements as a new mutagenic source for genetic modification, there still exist some disputes about its mutagenic mechanisms because of its short-penetrating property. In present research, Arabidopsis thaliana transgenic for GUS recombination substrate was used to evaluate the genomic instability induced by irradiations of alpha particle (3.3MeV) and Low-energy-Argon ion (30 KeV). A pronounced effects of alpha particle irradiation to Arabidopsis thaliana seedlings and Argon ion irradiation to seeds on the somatic homologous recombination frequency (sHRF) were reported. The sHRFs increased 1.88-fold and 2.42-fold, respectively, which indicated that the short-penetrating radiation could effectively induce the plant genomic instability in either dry seeds or seedlings with active metabolism. The local alpha particle irradiation of root was ...
2008-08-12
Routine environmental audit of the Y-12 Plant, Oak Ridge, Tennessee
Energy Technology Data Exchange (ETDEWEB)
This report documents the results of the routine environmental audit of the Oak Ridge Y-12 Plant (Y-12 Plant), Anderson County, Tennessee. During this audit, the activities conducted by the audit team included reviews of internal documents and reports from previous audits and assessments; interviews with U.S. Department of Energy (DOE), State of Tennessee regulatory, and contractor personnel; and inspections and observations of selected facilities and operations. The onsite portion of the audit was conducted August 22-September 2, 1994, by the DOE Office of Environmental Audit (EH-24), located within the Office of Environment, Safety and Health (EH). DOE 5482.1 B, {open_quotes}Environment, Safety, and Health Appraisal Program,{close_quotes} establishes the mission of EH-24 to provide comprehensive, independent oversight of DOE environmental programs on behalf of the Secretary of Energy. The ultimate goal of EH-24 is enhancement of environmental ...
1994-09-01
International Nuclear Information System (INIS)
Wolsong 2, 3, and 4 are CANDU 6 pressurized heavy water nuclear power plants, each with a gross electrical output of 715 MW(e). The plants were constructed in the Republic of Korea during the 1990s. The three Wolsong units are based on the previous CANDU Wolsong Unit 1, declared in service in 1983. All four units are presently in commercial service. The Wolsong abnormal operating manuals were developed in a cooperative effort between Atomic Energy of Canada Limited, Korea Power Engineering Company staff, and Korea Electric Power Corporation. The role of Atomic Energy of Canada Limited in performing risk assessment studies and supporting CANDU stations for the preparation of emergency operating procedures has greatly benefited the Wolsong abnormal operating manual program. Korea Electric Power Corporation provided training and supervision, Korea Power Engineering Company Inc. prepared the documentation, and Korea Electric ...
Energy Technology Data Exchange (ETDEWEB)
Among the items of the Sunshine Project in fiscal 1981 for development of a solvent extraction and liquefaction plant, this paper describes the achievements in developing secondary hydrogenation. A small continuous hydrogenation device equipped with three reaction columns that can be filled with catalyst of 50 cc, and a dedicated testing room were designed, and orders were placed with manufacturers. The fabrication, assembly, delivery, installation, piping and wiring were all completed. The device passed a completion inspection based on the high-pressure gas safety assurance law in December 1981. After leakage due to gas and material oil was checked, a trial operation was performed, and verified of normal operation. A screening test was carried out on three kinds of commercially available and prototype catalysts before testing the SRC containing material for studying the secondary hydrogenation. The circulating solvent having a boiling point ...
1982-03-01
Preliminary experience with the new Harwell inactive vitrification pilot plant
International Nuclear Information System (INIS)
The decision of the United Kingdom to adopt a policy of solidification of high level waste had led to renewed interest in vitrification. The HARVEST process chosen is an adaptation of the FINGAL concept developed at Harwell 15 years ago. Because of certain changes in engineering design and differences in the composition of the waste, additional chemical engineering data are required for HARVEST. The new inactive pilot plant has been built to provide this information. Its size is virtually full-scale and batches of glass up to 1 tonne can be manufactured in vessels of diameter up to 750mm. Five glass-making runs have been carried out. Attention has concentrated on the performance of the off-gas system which employs wet methods. Carry-over of solids occurs, primarily as a result of physical entrainment. The carry-over of synthetic fission products is improved from 2.5 to 0.1% by directing the feed down the vessel walls. Most of the entrained ...
On-line tuning of a fuzzy-logic power system stabilizer
International Nuclear Information System (INIS)
A scheme for on-line tuning of a fuzzy-logic power system stabilizer is presented. firstly, a fuzzy-logic power system stabilizer is developed using speed deviation and accelerating power as the controller input variables. The inference mechanism of fuzzy-logic controller is represented by a decision table, constructed of linguistic IF-THEN rules. The Linguistic rules are available from experts and the design procedure is based on these rules. It assumed that an exact model of the plant is not available and it is difficult to extract the exact parameters of the power plant. Thus, the design procedure can not be based on an exact model. This is an advantage of fuzzy logic that makes the design of a controller possible without knowing the exact model of the plant. Secondly, two scaling parameters are introduced to tune the fuzzy-logic power system stabilizer. These scaling parameters are the outputs of another fuzzy-logic ...
2002-01-01
Energy Technology Data Exchange (ETDEWEB)
Biomass and nutrient dynamics of black spruce seedlings during the hardening phase of the greenhouse rotation were examined after four pre-hardening fertilization regimes - conventional, constant-rate loading, exponential loading, and high exponential loading (delivering respectively 15, 40, 40 and 60 mg N seedling{sup -1}) - in order to assess nutrient dilution and steady-state nutrition. Although height growth of seedlings had virtually ceased during hardening, shoot biomass increased 99-142% and root biomass increased five- to tenfold depending on treatment. The biomass increase compromised steady-state nutrient status by diluting internal nutrient pools as nutrient supply was unable to keep up with growth. Soil nutrient levels were rapidly depleted during this period because of plant uptake and lack of fertilizer supplementation. Pre-hardening nutrient loading partly countered and delayed dilution effects, especially when applied exponentially and at high dose ...
1997-07-01
HEXTRAN-SMABRE calculation of the 6th AER Benchmark, main steam line break in a WWER-440 NPP
International Nuclear Information System (INIS)
The sixth AER benchmark is the second AER benchmark for couplings of the thermal hydraulic codes and three dimensional neutron kinetic core models. It concerns a double end break of one main steam line in a WWER-440 plant. The core is at the end of its first cycle in full power conditions. In VTT HEXTRAN2.9 is used for the core kinetics and dynamics and SMABRE4.8 as a thermal hydraulic model for the primary and secondary loop. The plant model for SMABRE consists mainly of two input models, Loviisa model and a standard WWER-440/213 plant model. The primary loop includes six separate loops, the pressure vessel is divided into six parallel channels in SMABRE and the whole core calculation is performed in the core with HEXTRAN. The horizontal steam generators are modelled with heat transfer tubes in five levels and vertically with two parts, riser and downcomer. With this kind of detailed modelling of steam ...
2003-11-01
Energy Technology Data Exchange (ETDEWEB)
Owing to their key function in power production the technology of gas- and steam turbines has a very high importance. Gas turbines in particular have become much more efficient and show higher performance in cogeneration plants. The VDI group on materials engineering puts these issues at the centre of this report whose focus is on measures necessary to increase plant availability: damage analysis, materials optimisation, supervision of construction and repair. The report which looks at applications and practical experience is adressed to operators of gas-, steam-, and water turbine plants, manufacturers of turbines and their components as well as maintenance companies, experts and insurance engineers. (orig.) [German] Aufgrund ihrer Schluesselposition bei der Stromerzeugung kommen den Gas- und Dampfturbinen eine sehr hohe technische Bedeutung zu. Insbesondere die Gasturbine macht in den letzten Jahren ...
1998-07-01
EDF approach on OD corrosion of SG tubes
Energy Technology Data Exchange (ETDEWEB)
The secondary side corrosion of steam generator tubes is the main degradation of components in operating power plants, strongly impacted by chemistry. This is why EDF has largely studied the chemical parameters in its 56 PWRs which might influence corrosion development. The results of 168 hideout returns of chemical species performed on the French plants allowed to draw conclusions on where chemical species are likely to concentrate in steam generators and on the influence of several contaminants on corrosion processes: sodium, chloride, phosphate, organic compounds, etc... Based on laboratory studies and plants feedback, new chemistry specifications were established and are now applied to EDF units to minimize corrosion and operating costs and to provide a good availability while maintaining an excellent safety. Boric acid is added in the secondary water of the 10 oldest units with Inconel 600 MA ...
1998-12-31
Assessment of energy performance in the life-cycle of biogas production
International Nuclear Information System (INIS)
Energy balances are analysed from a life-cycle perspective for biogas systems based on 8 different raw materials. The analysis is based on published data and relates to Swedish conditions. The results show that the energy input into biogas systems (i.e. large-scale biogas plants) overall corresponds to 20-40% (on average approximately 30%) of the energy content in the biogas produced. The net energy output turns negative when transport distances exceed approximately 200 km (manure), or up to 700 km (slaughterhouse waste). Large variations exist in energy efficiency among the biogas systems studied. These variations depend both on the properties of the raw materials studied and on the system design and allocation methods chosen. The net energy output from biogas systems based on raw materials that have high water content and low biogas yield (e.g. manure) is relatively low. When energy-demanding handling of the raw materials is required, the energy input increases ...
2006-03-01
Analysis of Selected Two-Phase Flow Phenomena in VVER Reactors with Horizontal Steam Generators
International Nuclear Information System (INIS)
Since 1984 the thermal-hydraulic code ATHLET has been also applied for the analyses of LOCA and transients in VVER plants. The specific design of these plants especially of the steam generator design requires a specific modelling of the phenomena which may occur under LOCA and transient conditions in these plants. Differences in design compared to the design of western reactors have been briefly listed. Specific phenomena occurring under small leak accidents are shortly described. The consideration of the simulation of the boiler-condenser mode illustrates the modelling requirements for a code which may be applied to the prediction of such a thermal-hydraulic behaviour. Facing the lack of experimental data, the reliability of the simulation has been discussed by means of plausibility studies based on the momentum balance for steam and water. In summary: The VVER reactors differ in design compared to reactors of western ...
1992-04-06
Energy Technology Data Exchange (ETDEWEB)
After an international ideas competition by TNC Switzerland and Germany in 1996, six companies where given the opportunity to construct a prototype of their newly developed integrated PV-sound barrier concepts. The main goal was to develop highly integrated concepts, allowing the reduction of PV sound barrier systems costs, as well as the demonstration of specific concepts for different noise situations. This project is strongly correlated with a German project. Three of the concepts of the competition are demonstrated along a highway near Munich, constructed in 1997. The three Swiss installations had to be constructed at different locations, reflecting three typical situations for sound barriers. The first Swiss installation was the world first Bi-facial PV-sound barrier. It was built on a highway bridge at Wallisellen-Aubrugg in 1997. The operational experience of the installation is positive. But due to the different efficiencies of the two cell sides, its specific yield lies ...
2002-07-01
Energy Technology Data Exchange (ETDEWEB)
The Outstanding Achievement Award in Water Pollution Control' is intended to recognize the water pollution control program that best demonstrates achieving significant, lasting, and measurable excellence in water-quality improvement in preventing water-quality degradation in a region, basin, or water body. This article is about the 1991 Award. This year, WPCF honored Los Angeles Hyperion Treatment Plant with a citation of outstanding achievement. To qualify for this honor, Hyperion has remarkably improved the quality of wastewater discharged to Santa Monica Bay since 1985. Capital programs developed by Los Angeles to achieve this rapid improvement, coined the Hyperion Improvement Program (HIP), reflect the city's commitment to protect the valuable resource of Santa Monica Bay. The HIP was conceived in 1986 to cease sludge ocean disposal by the end of 1987 and expedite effluent quality improvement before 1991, when the full secondary expansion is ...
1991-11-01
International Nuclear Information System (INIS)
Piping systems transporting high-pressure fluid will release a large amount of energy, leading to whipping of the broken pipe as well as impingement of the ejecting fluids on adjacent structures if they fracture unstably. Postulation of such an event in design of piping systems in nuclear power plants often requires various counter measures such as installation of pipe whip restraints or jet impingement shields to prevent such damage. One of the approaches to justify exclusion of unstable fracture from the design conditions is leak-before-break (LBB) analysis. In order to demonstrate LBB behavior, it is necessary to prove that in the presence of a part-through wall flaw in the pipe, this flaw will not grow through the wall under fatigue loading and is stable (level 2 LBB) and that the leak of fluid through the penetration is detected by leak detection systems before unstable fracture occurs (level 3 LBB). If this can be demonstrated in plant ...
2006-11-01
Energy Technology Data Exchange (ETDEWEB)
Field data for validating plume models were collected in and around the Bull Run Steam Plant during two four-week periods between July and October, 1982. The field measurements were the second phase of the Plume Model Validation and Development (PMV and D) program. The Bull Run Steam Plant is located near Oak Ridge, Tennessee, and the area is described as the ''Moderately Complex Site'' to distinguish it from the ''Plains Site'' in eastern Illinois, which was the scene of the first phase of the PMV and D study conducted in 1980-81. The measurement program consisted of a set of meteorological, source, aerometric, and tracer measurements to track and characterize the plume. The tracer measurements constituted the largest portion of the total effort, and it involved the release of SF/sub 6/ tracer gas from the stack, and the sampling and analysis of nearly 64,000 air samples ...
1985-05-01
ORALLOY (93.2 235U) METAL CYLINDER WITH BERYLLIUM TOP REFLECTOR
International Nuclear Information System (INIS)
A variety of critical experiments were constructed of enriched uranium metal during the 1960s and 1970s at the Oak Ridge Critical Experiments Facility (ORCEF) in support of criticality safety operations at the Y-12 Plant. The purposes of these experiments included the evaluation of storage, casting, and handling limits for the Y-12 Plant and providing data for verification of calculation methods and cross-sections for nuclear criticality safety applications. These included solid cylinders of various diameters, annuli of various inner and outer diameters, two and three interacting cylinders of various diameters, and graphite and polyethylene reflected cylinders and annuli. Of the hundreds of delayed critical experiments, one experiment was comprised of a stack of approximately 7-inch-diameter metal discs. The bottom of the stack consisted of uranium with an approximate height of 4-1/8 inches. The top of the stack consisted of beryllium with an ...
Implementation of integrated safeguards in Nuclear Fuel Plant at Pitesti, Romania
International Nuclear Information System (INIS)
The nuclear activity was conducted for many years in Romania under Traditional Safeguards (TS) and has developed in good conditions the specific nuclear safeguards. Now there is a good opportunity to improve the performance and quality of the safeguards activity and at the same time to increase the accountancy and control of nuclear materials by passing to Integrated Safeguards (IS) implementation. The legal framework is the Law 100/2000 for ratification of the Protocol between Romania and International Atomic Energy Agency (IAEA), additional completion to the Agreement between the Socialist Republic of Romania Government and IAEA relating to safeguards. It is part of the Treaty on the non-proliferation of nuclear weapons published in the Official Gazette no. 3/31 January 1970, and the Additional Protocol published in the Official Gazette no. 295/ 29.06.2000. The first discussion about Integrated Safeguards (IS) between the Nuclear Fuel Plant ...
2009-10-12
International Nuclear Information System (INIS)
Design improvements are being incorporated into the heavy water management systems at Wolsong 2,3 and 4 to reduce the load on the vapour recovery driers and upgraders and the heavy water losses via the stack. There will also be improvements to monitor heavy water and tritium releases. This paper describes the improvements, gives background on heavy water balance mechanism, the historical trends for heavy water recovery/losses and estimated dose to the member of the public critical group resulting from the airborne and waterborne releases. The measured tritium activity levels in the heat transport system (HTS) and moderator system at Wolsong 1 are given. Using these activity levels and heavy water loss data, tritium losses from the dried and ventilated areas are estimated. A qualitative assessment of expected heavy water and tritium releases has been performed for Wolsong 2, 3 and 4. CANDU 6 plants continue to perform well ...
1994-03-01
Annual report on heavy water reactor fuel fabrication
Energy Technology Data Exchange (ETDEWEB)
The CANDU-type nuclear fuel localization project started in 1981, and mass-production system completed in 1987 through the pilot scale demonstration of fuel manufacturing. Since the completion of the mass-production system, about 24,000 fuel bundles (450 ton-U) had been delivered to Wolsung Nuclear Power Plant by the end of 1992, according to the fuel supply contracts with KEPCO. The superiority of KAERI-made nuclear fuel has been demonstrated by having achieved the highest utilization factor in the world in 1992. In 1993, as contracted, 4,824 fuel bundles well fabricated and delivered to Wolsung Nuclear Power Plant. The process improvement, quality control, safety management, safeguards of nuclear materials and various kinds of audits have also been performed in the course for fuel manufacturing. Especially in 1993, the difficulties of the reduction of participating work-force were overcome by improving the manufacturing ...
1994-03-01
International Nuclear Information System (INIS)
To estimate the success criteria of an operator's action time for a probabilistic safety/risk assessment (PSA/PRA) of a nuclear power plant, the information from a safety analysis report (SAR) and/or that by using a simplified simulation code such as the MAAP code has been used in a conventional PSA. However, the information from these is often too conservative to perform a realistic PSA for a risk-informed application. To reduce the undue conservatism, the use of a best-estimate thermal hydraulic code has become an essential issue in the latest PSA and it is now recognized as a suitable tool. In the same context, the 'ASME PRA standard' also recommends the use of a best-estimate code to improve the quality of a PSA. In Korea, a platform to use a best-estimate thermal hydraulic code called the MARS code has been developed for the PSA of the Korea standard nuclear power plant (KSNP). This study has proposed an estimation ...
2007-04-01
Energy Technology Data Exchange (ETDEWEB)
To estimate the success criteria of an operator's action time for a probabilistic safety/risk assessment (PSA/PRA) of a nuclear power plant, the information from a safety analysis report (SAR) and/or that by using a simplified simulation code such as the MAAP code has been used in a conventional PSA. However, the information from these is often too conservative to perform a realistic PSA for a risk-informed application. To reduce the undue conservatism, the use of a best-estimate thermal hydraulic code has become an essential issue in the latest PSA and it is now recognized as a suitable tool. In the same context, the 'ASME PRA standard' also recommends the use of a best-estimate code to improve the quality of a PSA. In Korea, a platform to use a best-estimate thermal hydraulic code called the MARS code has been developed for the PSA of the Korea standard nuclear power plant (KSNP). This study has ...
2007-04-15
Research on pipe whip and jet under LOCA conditions, (2)
International Nuclear Information System (INIS)
The paper describes the experimental and analytical results of the pipe whip tests performed under the PWR LOCA conditions using 4, 6 and 8 inch test pipes. The tests were carried out at an initial pressure and a temperature of 15.7 MPa and 325 "0C. Two different types of tests were performed. One was the cantilever type pipe whip test using the test pipe of 3000 mm in length and U-shaped restraints. The other was the cross-over leg pipe whip test using a 1/6 model of piping in the PWR nuclear power plants. The cantilever type pipe whip tests were performed to investigate the influences of overhang length and pipe diameter on the pipe whip behavior. The movement of the test pipe is limited effectively by the restraints when the overhang length is short. The restraint force increases in proportion to the breaking area. The cross-over leg pipe whip test was performed to demonstrate ...
Performance of spark ignited gas engine and dual fuel engine, and their application
Energy Technology Data Exchange (ETDEWEB)
This paper describes a practical knowledge on gas engine performance and combustion characteristics which are required by experimental studies for two types of developed gas burning engines, i. e. a spark ignited gas engine and a dual fuel engine, and also introduces their practical use and application. As for dual fuel engine performance, a manifold air pressure of about 27% was decreased, a scavenging ratio of 23% reduced and an exhaust temperature at the turbine inlet on 14% was increased at the gas engine operation under the mean effective cylinder pressure of 1.22 MPa in comparison with the diesel operation. Furthemore, empirical data on the effect of excess air ration on the engine performance and combustion characteristics, a risk of knocking during changing over on the dual fuel engine operation, and the rated output in case of using alternate fuel gas were reported. Two spark ignited gas engines with a rated output ...
1988-12-01
Integrated design environment for human performance and human reliability analysis
Energy Technology Data Exchange (ETDEWEB)
Work over the last few years at the Idaho National Engineering and Environmental Laboratory (INEEL) has included a major focus on applying human performance and human reliability knowledge and methods as an integral element of system design and development. This work has been pursued in programs in a wide variety of technical domains, beginning with nuclear power plant operations. Since the mid-1980`s the laboratory has transferred the methods and tools developed in the nuclear domain to military weapons systems and aircraft, offshore oil and shipping operations, and commercial aviation operations and aircraft design. Through these diverse applications the laboratory has developed an integrated approach and framework for application of human performance analysis, human reliability analysis (HRA), operational data analysis, and simulation studies of human performance to the design and development of ...
1997-05-01
ESBWR related passive decay heat removal tests in PANDA
International Nuclear Information System (INIS)
A number of test series to investigate passive safety systems for the next generation of Light Water Reactors have been performed in the PANDA multi-purpose facility at the Paul Scherrer Institut (PSI). The large scale thermal-hydraulic test facility allows to investigate LWR containment phenomena and system behaviour. PANDA was first used to examine the Passive Containment Cooling System (PCCS) for the Simplified Boiling Water Reactor (SBWR). In 1996 new test series were initiated; all related to projects of the EC Fourth Framework Programme on Nuclear Fission Safety. One of these projects (TEPSS) is focused on the European Simplified Boiling Water Reactor (ESBWR). The ESBWR containment features and PCCS long-term post LOCA response were investigated in PANDA. The PCCS start-up was demonstrated, the effect of nitrogen hidden somewhere in the drywell and released later in the transient was simulated and the effect of light gases (helium) on the PCCS ...
1999-04-19
Large eddy simulation based fire modeling applications for Indian nuclear power plant
Energy Technology Data Exchange (ETDEWEB)
Full text of publication follows: The Nuclear Power Plants (NPPs) are always designed for the highest level of safety against postulated accidents which may be initiated due to internal or external causes. One of the external/internal causes, which may lead to accident in the reactor and its associated systems, is fire in certain vital areas of the plant. Conventionally, the fire containment approach and/or the fire confinement approach is used in designing the fire protection systems of NPPs. Indian NPPs (PHWRs) follow the combined approach to ensure plant safety and all newly designed plants are required to comply with the provisions of Atomic Energy Regulatory Board (AERB) fire safety Guide. In respect of older plants, the reassessment of adequacy of fire safety provisions in the light of current advances has becomes essential so as to decide upon the steps for retrofitting. ...
2005-07-01
Hydroelectric and pumped storage plants
Energy Technology Data Exchange (ETDEWEB)
All power plant engineers face the problem of peak power demands. Pumped storage plants are used to generate peak load power by pumping up water utilizing off-peak energy of hydrothermal and thermonuclear plants. This is the first accessible text/reference to cover hydroelectric power generation with emphasis on engineering to meet peak power demands by means of pumped storge plants, tidal power plants, and low head power generation. Text covers hydrology, mechanical and electrical equipment, accessories such as penstocks and valves, and civil engineering considerations. Contains descriptions of several existing plants. Includes 200 diagrams and 50 photographs.
1989-01-01
Hydroelectric and pumped storage plants
Energy Technology Data Exchange (ETDEWEB)
All power plant engineers face the problem of peak power demands. Pumped storage plants are used to generate peak load power by pumping up water utilizing off-peak energy of hydrothermal and thermonuclear plants. This is a reference to cover hydroelectric power generation with emphasis on engineering to meet peak power demands by means of pumped storage plants, tidal power plants, and low head power generation. Text covers hydrology, mechanical and electrical equipment, accessories such as penstocks and valves, and civil engineering considerations. Contains descriptions of several existing plants. Includes 200 diagrams and 50 photographs.
1988-01-01
Conception and design of steam power plants
International Nuclear Information System (INIS)
The manual presents the fundamentals of thermodynamics and fluid mechanics, the main components of steam power plants, and the power generation process. The following concepts and subjects are discussed at length: steam generator; steam turbines; turbogenerators; condensers; cooling technology; water/steam cycle and water treatment; design data of fossil-fuelled power plants; design and optimisation of nuclear power plant thermodynamics; pipelines and fittings; control systems in steam power plants; connection to the electricity grid and self-supply of thermal power plants; power plant transformer concepts and definitions. (HAG).
ORALLOY (93.15 235U) METAL ANNULI WITH BERYLLIUM CORE
International Nuclear Information System (INIS)
A variety of critical experiments were constructed of enriched uranium metal during the 1960s and 1970s at the Oak Ridge Critical Experiments Facility (ORCEF) in support of criticality safety operations at the Y-12 Plant. The purposes of these experiments included the evaluation of storage, casting, and handling limits for the Y-12 Plant and providing data for verification of calculation methods and cross-sections for nuclear criticality safety applications. These included solid cylinders of various diameters, annuli of various inner and outer diameters, two and three interacting cylinders of various diameters, and graphite and polyethylene reflected cylinders and annuli. Of the hundreds of delayed critical experiments, two were performed that consisted of uranium metal annuli with a solid beryllium metal core. The outer diameter of the annuli was approximately 13 or 15 inches with an inner diameter of 7 inches. The ...
Energy Technology Data Exchange (ETDEWEB)
Organic Rankine cycles (ORC) have unique properties that are well suited to solar power generation. In this work design and performance calculations are performed using MatLab/SimuLink computational environment. The cycle consists of thermal solar collectors (Flat Plate Solar Collector (FPC), or Parabolic Trough Collector (PTC), or Compound Parabolic Concentrator (CPC)) for heat input, expansion turbine for work output, condenser unit for heat rejection, pump unit, and Reverse Osmosis (RO) unit. Reverse osmosis unit specifications used in this work is based on Sharm El-Shiekh RO desalination plant. Different working fluids such as: butane, isobutane, propane, R134a, R152a, R245ca, and R245fa are examined for FPC. R113, R123, hexane, and pentane are investigated for CPC. Dodecane, nonane, octane, and toluene are allocated for PTC. The proposed process units are modeled and show a good validity with literatures. Exergy and ...
2010-11-15
A Preliminary Study for the Analysis of PSA Success Criteria for Kori Units 3 and 4
Energy Technology Data Exchange (ETDEWEB)
This paper identifies the event sequences that require thermal-hydraulic analyses for the success criteria of probabilistic safety analysis (PSA). The selection of the sequences is performed based on the review of the NEI Peer Review Process Guidance and ASME PRA Standard. Success criteria are the important element of PSA quality. Success criteria decide the success or failure of the key function in the PSA event tree. It is defined as a minimum set of components/trains of system required to mitigate an accident. Thermal-hydraulic codes are generally used to derive time-related criteria in the PSA, such as operator action time used in human reliability analysis (HRA), event timing, and time to recover the component or the power. This paper suggests the use of the MARS code for the T-H analysis to obtain the success criteria and sequence timing, and operator action time. In the Kori Units 3 and 4 PSA report, the T-H analyses for those criteria were ...
2009-10-15
A Preliminary Study for the Analysis of PSA Success Criteria for Kori Units 3 and 4
International Nuclear Information System (INIS)
This paper identifies the event sequences that require thermal-hydraulic analyses for the success criteria of probabilistic safety analysis (PSA). The selection of the sequences is performed based on the review of the NEI Peer Review Process Guidance and ASME PRA Standard. Success criteria are the important element of PSA quality. Success criteria decide the success or failure of the key function in the PSA event tree. It is defined as a minimum set of components/trains of system required to mitigate an accident. Thermal-hydraulic codes are generally used to derive time-related criteria in the PSA, such as operator action time used in human reliability analysis (HRA), event timing, and time to recover the component or the power. This paper suggests the use of the MARS code for the T-H analysis to obtain the success criteria and sequence timing, and operator action time. In the Kori Units 3 and 4 PSA report, the T-H analyses for those criteria were ...
2009-10-01
Energy Technology Data Exchange (ETDEWEB)
The primary objective of the work was to establish and verify cost and performance parameters for integrated concepts in which agricultural and other biomass derived pyrolysis oils are utilised as fuel for small scale heat and power production. Production of non-food value-added products was also considered. The cost and performance studies were carried out in Spain, Denmark, and Finland, using olive oil farming residues, straw, and rapeseed oil pressing residues and straw as fuels for pyrolysis, respectively. Use of forest residue wood fuel was also considered in the Finnish vase. A rather wide selection of biomasses was therefore studied within the project. The secondary objective was to generate experimental data to verify and support the critical features within these concepts. Experimental work, modelling, and techno-economic assessments were carried out within the project. The experimental part included: Determination of flash pyrolysis ...
1997-07-01
International Nuclear Information System (INIS)
As a continuation of its efforts to provide methodologies and tools to Member States to carry out comparative assessment and analyse priority environmental issues related to the development of the electric power sector, the IAEA has completed a new version of the Wien Automatic System Planning (WASP) Package WASP-IV for carrying out power generation expansion planning taking into consideration fuel availability and environmental constraints. This manual constitutes a part of this work and aims to provide users with a guide to use effectively the new version of the model WASP-IV. WASP was originally developed in 1972 by the Tennessee Valley Authority and the Oak Ridge National Laboratory in the USA to meet the IAEA needs to analyse the economic competitiveness of nuclear power in comparison to other generation expansion alternatives for supplying the future electricity requirements of a country or region. Previous versions of the model were used by Member States in many national and ...
1997-12-01
Advanced applications of water cooled nuclear power plants
International Nuclear Information System (INIS)
By August 2007, there were 438 nuclear power plants (NPPs) in operation worldwide, with a total capacity of 371.7 GW(e). Further, 31 units, totaling 24.1 GW(e), were under construction. During 2006 nuclear power produced 2659.7 billion kWh of electricity, which was 15.2% of the world's total. The vast majority of these plants use water-cooled reactors. Based on information provided by its Member States, the IAEA projects that nuclear power will grow significantly, producing between 2760 and 2810 billion kWh annually by 2010, between 3120 and 3840 billion kWh annually by 2020, and between 3325 and 5040 billion kWh annually by 2030. There are several reasons for these rising expectations for nuclear power: - Nuclear power's lengthening experience and good performance: The industry now has more than 12 000 reactor years of experience, and the global average nuclear plant availability during 2006 reached ...
2007-07-01
Advanced applications of water cooled nuclear power plants
International Nuclear Information System (INIS)
By August 2007, there were 438 nuclear power plants (NPPs) in operation worldwide, with a total capacity of 371.7 GW(e). Further, 31 units, totaling 24.1 GW(e), were under construction. During 2006 nuclear power produced 2659.7 billion kWh of electricity, which was 15.2% of the world's total. The vast majority of these plants use water-cooled reactors. Based on information provided by its Member States, the IAEA projects that nuclear power will grow significantly, producing between 2760 and 2810 billion kWh annually by 2010, between 3120 and 3840 billion kWh annually by 2020, and between 3325 and 5040 billion kWh annually by 2030. There are several reasons for these rising expectations for nuclear power: - Nuclear power's lengthening experience and good performance: The industry now has more than 12 000 reactor years of experience, and the global average nuclear plant availability during 2006 reached ...
1996-07-21
Advanced applications of water cooled nuclear power plants
International Nuclear Information System (INIS)
By August 2007, there were 438 nuclear power plants (NPPs) in operation worldwide, with a total capacity of 371.7 GW(e). Further, 31 units, totaling 24.1 GW(e), were under construction. During 2006 nuclear power produced 2659.7 billion kWh of electricity, which was 15.2% of the world's total. The vast majority of these plants use water-cooled reactors. Based on information provided by its Member States, the IAEA projects that nuclear power will grow significantly, producing between 2760 and 2810 billion kWh annually by 2010, between 3120 and 3840 billion kWh annually by 2020, and between 3325 and 5040 billion kWh annually by 2030. There are several reasons for these rising expectations for nuclear power: - Nuclear power's lengthening experience and good performance: The industry now has more than 12 000 reactor years of experience, and the global average nuclear plant availability during 2006 reached ...
2007-11-23
The protein encoded by the rolB plant oncogene hydrolyses indole glucosides.
UK PubMed Central (United Kingdom)
The rolB gene of Agrobacterium rhizogenes, whose expression stimulates the formation of roots by transformed plant tissues and other growth alterations in transgenic plants, codes for a beta-glucosidase...Full Text Available
1991-11-01
Steam turbines for cogeneration plants; Dampfturbinen fuer die Kraft-Waerme-Kopplung
Energy Technology Data Exchange (ETDEWEB)
The demand for cogeneration plants is growing worldwide. For the combination of electricity generation and heat extraction in power stations facilitates an excellent fuel exploitation and makes the operator of the plant independent from external energy suppliers. (orig.)
2006-07-01
Potential of plant genetic systems for monitoring and screening mutagens
UK PubMed Central (United Kingdom)
Plants have too long been ignored as useful screening and monitoring systems of environmental mutagens. However, there are about a dozen reliable, some even unique, plant genetic systems that can increase...Full Text Available
1978-12-01
UK PubMed Central (United Kingdom)
The gram-negative plant-pathogenic bacterium Xanthomonas campestris pv. vesicatoria is the causative agent of bacterial spot disease in pepper and tomato plants, which leads to economically...Full Text Available
2005-11-01
Does Water Deficit Stress Promote Ethylene Synthesis by Intact Plants? 1
UK PubMed Central (United Kingdom)
The effect of plant water deficit on ethylene production by intact plants was tested in three species, beans (Phaseolus vulgaris L.), cotton (Gossypium hirsutum L.)...Full Text Available
1990-12-01
UK PubMed Central (United Kingdom)
BackgroundPlastid genome content and protein sequence are highly conserved across land plants and their closest algal relatives. Parasitic plants, which obtain some or all of their...Full Text Available
Energy Technology Data Exchange (ETDEWEB)
This paper evaluates a new power tower concept that offers significant benefits for commercialization of power tower technology. The concept uses a molten nitrate salt centralreceiver plant to supply heat, in the form of combustion air preheat, to a conventional combined-cycle power plant. The evaluation focused on first commercial plants, examined three plant capacities (31, 100, and 300 MWe), and compared these plants with a solar-only 100-MWe plant and with gas-only combined-cycle plants in the same three capacities. Results of the analysis point to several benefits relative to the solar-only plant including low energy cost for first plants, low capital cost for first plants, reduced risk with respect to business uncertainties, and the potential for new markets. In addition, ...
1994-10-01
by American scientists, ecosystems containing a greater number of plant species, produce more biomass.This result ...to meet the increasing demand for land for farmland planted with monocultures, buildings and roads.For ...have hypothesized that greater ecological diversity (diversity of plant and animal species) leads to a greater
Pumped storage plants in a new framework - challenges and consequences
Energy Technology Data Exchange (ETDEWEB)
Originally designed exclusively for peak load covering, pumped storage plants are now faced with new challenges brought about by the deregulation of the electricity market and the substantial growth of wind power capacity. Today's pumped storage plants are started more frequently and often for shorter periods of time. The grid controlling tasks have increased the importance of the role played by this type of power plant and improved sales considerably. But the operational demands have grown substantially as well. This paper discusses the ensuing adaptation of power plant operation as well as options available to power plant operators. (orig.)
2006-07-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.