WorldWideScience
 
 
1

Seismic qualification method of equipment for nuclear power plant  

Energy Technology Data Exchange (ETDEWEB)

Safety related equipment installed in Korean Nuclear Power Plants are required to perform a safety function during and after a seismic event. To accomplish this safety function, they must be seismically qualified in accordance with the intent and requirements of the USNRC Reg. Guide 1.100 Rev. 02 and IEEE Std. 344-1987. This paper defines and summarizes acceptable criteria and procedures, based on the Korean experience, for seismic qualification of purchased equipment to be installed in a nuclear power plant. As such the paper is intended to be a concise reference by equipment designers, architectural engineering company and plant owners in uniform implementation of commitments to nuclear regulatory agencies such as the USNRC or Korea Institute of Nuclear Safety (KINS) relating to adequacy of seismic Category 1 equipment. Thus, the paper provides the methodologies which can be used for qualifying equipment for safely related service in Nuclear ...

1995-12-31

2

Revision I July 29, 2009 - Alpha Magnetic Spectrometer - NASA  

Science.gov (United States)

MIL-STD-129. N. 5/15/97. Standard Practice for Military Marking. MIL-STD-130. K. 1/15/00. Identification Marking of U.S. Military Property. MIL-STD-2073-1 ...

3

~&/oLj - NASA  

Science.gov (United States)

and/or MIL-STD-2073-1 and MIL-STD-2073-2, as applicable, except as noted below: NONE. (b) The Contractor shall pack potentially hazardous items in ...

4

Packaging, Storage, and Containerization Center: Reports ...  

Science.gov (United States)

... 9 SIMPLIFICATION STUDY RECOMMENDATIONS - MIL-STD-2073-1/2 ... SIMPLIFICATION STUDY RECOMMENDATIONS - MIL-STD-2073-1/2 ...

1993-12-01

5

NAS15-10000  

Science.gov (United States)

D-11. The Contractor shall pack and mark all hardware deliverable under this ... Handling, and Transportation, and/or MIL-STD-2073-1 and MIL-STD 2073-2, ...

6

SECTION D - PACKAGING AND MARKING - NASA  

Science.gov (United States)

D.1 PACKAGING AND MARKING (NASA 18-52.210-75) (SEP 1990) ... Packaging, Handling, and Transportation, and/or MIL-STD-2073-1 and MIL-STD- 2073-2, ...

7

Project Technical ... - Alpha Magnetic Spectrometer - NASA  

Science.gov (United States)

Standard Practice for Military Marking. MIL-STD-130. K. 1/15/00. Identification Marking of U.S. Military Property. MIL-STD-2073-1 D. Notice 1. 12/15/99. 05/10/ 02 ...

8

Packaging and ... - server-mpo.arc.nasa.gov Default Home - NASA  

Science.gov (United States)

... the provisions of NASA Handbook (NHB) 6000.1, Requirements for Packaging, Handling, and Transportation, and/or MIL-STD-2073-1 and MIL-STD-2073-2, ...

9

AMS Project Plan - Alpha Magnetic Spectrometer - NASA  

Science.gov (United States)

Feb 19, 2009 ... Standard Practice for Military Marking. MIL-STD-130. K. 1/15/00. Identification Marking of U.S. Military Property. MIL-STD-2073-1. D. Notice 1 ...

10

Update of the Navy Contract Writing Guide  

Science.gov (United States)

... These requirements may be expressed in terms of MIL-STD-2073-1, DoD Material Procedures for Development and Application of Packaging ...

2004-06-01

11

NASA Procedural Requirements  

Science.gov (United States)

2.1.1 Levels of preservation and packaging and the levels of packing to be applied selectively are defined in MIL-STD-2073-1 and are mandatory for use or ...

12

United States Air Force Computer-Aided Acquisition and ...  

Science.gov (United States)

... of Packaging Requirements. MIL-STD-2073-1 DoD Packaging Data Forms Instruction for Preparation and Use. I DATA ...

1988-10-01

13

Military Handbook: Electrostatic Discharge Control Handbook ...  

Science.gov (United States)

... (Metric) 80 Page 24. MIL-HDBK-263B MIL-STD-2073-1 - DOD Materiel Procedures for Development and Application of Packaging Requirements. ...

1994-07-31

14

Construction, Geology, and Aquifer Testing of the Maalo Road ...  

Science.gov (United States)

... Construction, Geology, and Aquifer Testing of the Maalo ... 8-98) Prescribed by ANSI Std Z39-18 Page 3. Construction, Geology, and Aquifer Testing ...

2011-05-13

15

COTS GUIDE - Commercial Off-the-Shelf  

Science.gov (United States)

consider applying the requirements of MIL-STD-2073-1. 5.2.5. Sustainability. Because of the design control the. Government has had over. XIL-SPEC designs, ...

16

CALS-HSC Data Element Dictionary  

Science.gov (United States)

... HAZARDOUS CODE IS REQUIRED BY MIL-STD-2073-1. Structure/Length: A01 Item/Code Assigned: N-NONHAZARDOUS ITEM Y-REGULATED ...

1992-10-01

17

Bulk CS Overpack Salvage Drums United Nations (UN) ...  

Science.gov (United States)

... SHEET. UNLESS OTHERWISE SPECIFIED, MATERIALS WILL BE MINIMUM SIZE lAW MIL-STD-2073-1. 18. TOLERANCES ...

1997-08-01

18

Proceedings of the 1988 IEEE international conference on robotics and automation. Volume 1  

International Nuclear Information System (INIS)

These proceedings compile the papers presented at the international conference (1988) sponsored by IEEE Council on ''Robotics and Automation''. The subjects discussed were: automation and robots of nuclear power stations; algorithms of multiprocessors; parallel processing and computer architecture; and U.S. DOE research programs on nuclear power plants.

1988-04-24

19

IEEE 8023 ethernet, current status and future prospects at the LHC  

CERN Document Server

The status of the IEEE 802.3 standard is reviewed and prospects for the future, including the new 10 Gigabit version of Ethernet, are discussed. The relevance of Ethernet for experiments at the CERN Large Hadron Collider is considered, with emphasis on on-line applications and areas which are technically challenging. 8 Refs.

2000-01-01

20

48 CFR 552.211-89 - Non-manufactured wood packaging material for export.  

Science.gov (United States)

...j-3/j-3311/DLAD/rev5.htm ), and MIL-STD-2073-1, Standard Practice for Military Packaging (and...Guidelines will comply with DLAD 47.305-1, and MIL-STD-2073-1. (f) Delays in delivery caused by...

2010-10-01

 
 
 
 
21

Designing a Truly Integrated (Onsite and Online) Conference: Concept, Processes, Solutions  

CERN Document Server

Web conferencing tools have entered the mainstream of business applications. Using web conferencing for IEEE conferences has a good potential of adding value to both organizers and participants. Authors propose a concept of Truly Integrated Conference (TIC) according to which a multi-point worldwide-distributed network of conference online authors/participants will enhance the standard (centralized) IEEE conference model, which requires attendance of the participants in person at the main conference location. The concept entails seamless integration of the onsite and online conference systems, including data/presentation, video, audio channels. Benefits and challenges of the TIC concept are analyzed. Requirements to the web conferencing system capable of supporting the TIC conference are presented and reviewed against commercial web conferencing tools. Case study of the IEEE Toronto International Conference ? Science and ...

2010-01-01

22

NREL preprints for the 23rd IEEE Photovoltaic Specialists Conference  

Energy Technology Data Exchange (ETDEWEB)

Topics covered include various aspects of solar cell fabrication and performance. Aluminium-gallium arsenides, cadmium telluride, amorphous silicon, and copper-indium-gallium selenides are all characterized in their applicability in solar cells.

1993-05-01

23

MSFC ESO Applied ... - Global Hydrology and Climate Center - NASA  

Science.gov (United States)

In the IEEE Marine Technology Society OCEANS 2009 Conference, Biloxi. October 26-29, 2009. Biloxi, MS. Al-Hamdan, M.; Estes, M.; Quattrochi, D.; Thom, R.; ...

24

IEEE International Symposium on Information Theory Held in ...  

Science.gov (United States)

... CW Helstrom, Chairman F. Beutler SA Kassam E. Biglien JW Modestino R E Blahutxi RL Pickholtz S. Carobanis HV Poor DJ Costello, Jr. ...

2011-05-14

25

*1-Front Piece - NASA Aqua  

Science.gov (United States)

properties such as effective particle size, thermody- namic phase (water, ice), cloud-top properties ...... Green, R.O., and J.E. Conel, 1995: Movement of ..... vertical hydrometeor profiles from passive micro- wave sensors. IEEE Trans. ...

26

Subjective Life Expectancy and Health Behaviors among STD Clinic Patients  

UK PubMed Central (United Kingdom)

ObjectivesTo examine whether people who expect to live longer engage in healthier behaviors relative to people who expect to live shorter lives.Full Text Available

2010-05-01

27

Chlamydial urethral infection in Teheran. A study of male patients attending an STD clinic.  

UK PubMed Central (United Kingdom)

The prevalence of chlamydial infection of the urethra was studied in 172 consecutive male patients attending a sexually transmitted disease clinic in Teheran. Chlamydia trachomatis was isolated in 8.8%...Full Text Available

1982-12-01

28

48 CFR 552.211-87 - Export packing.  

Science.gov (United States)

...furnished with commercial or military export packing. Military export packing, if offered, shall be in accordance with Mil-Std-2073-1 Level A or B as specified. If commercial export packing is offered, the offer or pricelist shall include...

2010-10-01

29

IEEE standard quality assurance program requirements for the design and manufacture of class 1E instrumentation and electric equipment for nuclear power generating station  

International Nuclear Information System (INIS)

The Institute of Electrical and Electronic Engineers (IEEE) standards for the quality assurance requirements for the design and manufacture of Class 1E instrumentation and electric equipment for a nuclear power generating station are presented. This standard establishes Quality Assurance Program requirements for electrical manufacturers. This standard, used in conjunction with ANSI N45.2-1977 and the supplemental standards to the extent referenced in this standard, is intended to meet the requirements of 10CFR50, Appendix B. These requirements are intended to assure that Class 1E instrumentation and electric equipment are responsibly engineered and manufactured from proper materials, that the manufacturing processes and practices are controlled, and that the manufacturing process produces a product of the required quality for Class 1E application.

30

IEEE [Institute of Electrical and Electronics Engineers] standards and nuclear software quality engineering  

International Nuclear Information System (INIS)

Significant new nuclear-specific software standards have recently been adopted under the sponsorship of the American Nuclear Society and the American Society of Mechanical Engineers. The interest of the US Nuclear Regulatory Commission has also been expressed through their issuance of NUREG/CR-4640. These efforts all indicate a growing awareness of the need for thorough, referenceable expressions of the way to build in and evaluate quality in nuclear software. A broader professional perspective can be seen in the growing number of software engineering standards sponsored by the Institute of Electrical and Electronics Engineers (IEEE) Computer Society. This family of standards represents a systematic effort to capture professional consensus on quality practices throughout the software development life cycle. The only omission-the implementation phase-is treated by accepted American National Standards Institute or de facto standards for programming languages.

1988-06-12

31

Chaos and bifurcation control of SSR in the IEEE second benchmark model  

International Nuclear Information System (INIS)

Linear and nonlinear state feedback controllers are proposed to control the bifurcation of a phenomenon in power system, this phenomenon of electro-mechanical interaction between the series resonant circuits and torsional mechanical frequencies of the turbine-generator sections, which known as subsynchronous resonance (SSR). The first system of the IEEE second benchmark model is considered. The dynamics of the two axes damper windings, automatic voltage regulator and power system stabilizer are included. The linear controller gives better initial disturbance response than that of the nonlinear, but in a small narrow region of compensation factors. The nonlinear controller not only can be easily implemented, but also it stabilizes the operating point for all values of the bifurcation parameter.

2004-07-01

32

Hot Cell Facility (HCF) Safety Analysis Report  

Energy Technology Data Exchange (ETDEWEB)

This Safety Analysis Report (SAR) is prepared in compliance with the requirements of DOE Order 5480.23, Nuclear Safety Analysis Reports, and has been written to the format and content guide of DOE-STD-3009-94 Preparation Guide for U. S. Department of Energy Nonreactor Nuclear Safety Analysis Reports. The Hot Cell Facility is a Hazard Category 2 nonreactor nuclear facility, and is operated by Sandia National Laboratories for the Department of Energy. This SAR provides a description of the HCF and its operations, an assessment of the hazards and potential accidents which may occur in the facility. The potential consequences and likelihood of these accidents are analyzed and described. Using the process and criteria described in DOE-STD-3009-94, safety-related structures, systems and components are identified, and the important safety functions of each SSC are described. Additionally, information which describes the safety management programs at ...

2000-11-01

33

Reliability assessment of hydrothermal generation systems containing pumped storage plant  

Energy Technology Data Exchange (ETDEWEB)

Previous models and evaluation techniques based on the Monte Carlo simulation for the reliability assessment of mixed hydrothermal generation systems are extended. Models for reservoirs on multiple rivers and pumped storage plants are developed. Operating and water management policies are extended to include the relative economical effects of operating alternative sources of generation. These effects and the benefits are described and discussed using an extended IEEE reliability test system. (Author).

1991-11-01

34

Optimal security-constrained power scheduling by Benders decomposition  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a Benders decomposition approach to determine the optimal day-ahead power scheduling in a pool-organized power system, taking into account dispatch, network and security constraints. The study model considers the daily market and the technical constraints resolution as two different and consecutive processes. The daily market is solved in a first stage subject to economical criteria exclusively and then, the constraints solution algorithm is applied to this initial dispatch through the redispatching method. The Benders partitioning algorithm is applied to this constraints solution process to obtain an optimal secure power scheduling. The constraints solution includes a full AC network and security model to incorporate voltages magnitudes as they are a critical factor in some real power systems. The algorithm determines the active power committed to each generator so as to minimize the energy redispatch cost subject to dispatch, network and security constraints. The ...

2007-05-15

35

High voltage high brightness electron accelerator with MITL voltage adder coupled to foilless diode  

International Nuclear Information System (INIS)

The design and analysis of a high brightness electron beam experiment under construction at Sandia National Laboratory is presented. The beam energy is 12 MeV, the current 35 endash 40 kA, the rms radius 0.5 mm, and the pulse duration FWHM 40 ns. The accelerator is SABRE [J. Corley, J. A. Alexander, P. J. Pankuch, C. E. Heath, D. L. Johnson, J. J. Ramirez, and G. J. Denison, in Proceedings of the Eighth International IEEE Pulsed Power Conference, San Diego, California, 1991 (IEEE, New York, 1991), p. 920], a pulsed inductive voltage adder, and the electron source is a magnetically immersed foilless diode. This experiment has as its goal to stretch the technology to the edge and produce the highest possible electron current in a submillimiter radius beam. copyright 1996 American Institute of Physics.

1995-10-13

36

Co-Authorship Networks in the Digital Library Research Community  

CERN Document Server

The field of digital libraries (DLs) coalesced in 1994: the first digital library conferences were held that year, awareness of the World Wide Web was accelerating, and the National Science Foundation awarded $24 Million (U.S.) for the Digital Library Initiative (DLI). In this paper we examine the state of the DL domain after a decade of activity by applying social network analysis to the co-authorship network of the past ACM, IEEE, and joint ACM/IEEE digital library conferences. We base our analysis on a common binary undirectional network model to represent the co-authorship network, and from it we extract several established network measures. We also introduce a weighted directional network model to represent the co-authorship network, for which we define $AuthorRank$ as an indicator of the impact of an individual author in the network. The results are validated against conference program committee members in the same period. The results ...

2005-01-01

37

Technical Publication Transfer Using O'Neil and Associates' Data Supporting ESC/MSL MILSTAR Program T O 31R2-2U-433: MIL-STD-1840A, MIL-D-28000A (IGES), MIL-M-28001B (SGML), MIL-R-28002A (Raster), MIL-D-28003 (CGM). Quick Short Test Report.  

Science.gov (United States)

The primary objective of the Air Force Continuous Acquisition and Life-Cycle Support (CALS) Test Network (AFCTN) is to evaluate the effectiveness of the CALS standards for technical data interchange and to demonstrate the technical capabilities and operat...

1994-01-01

38

Technical Publication Transfer T O 31R2-2U-432 Using O'Neil and Associates, Inc. Data Supporting ESC/MSL MILSTAR Program: MIL-STD-1840A, MIL-D-28000A (IGES), MIL-M-28001A (SGML), MIL-R-28002A (Raster), MIL-D-28003 (CGM). Quick Short Test Report.  

Science.gov (United States)

The primary objective of the Air Force Continuous Acquisition and Life-cycle Support (CALS) Test Network (AFCTN) is to evaluate the effectiveness of the CALS standards for technical data interchange and to demonstrate the technical capabilities and operat...

1994-01-01

39

Technical Publication TO 12R2-2ARC208-113 Transfer Using O'Neil and Associates' Data Supporting ESC/MSL's MILSTAR Program: MIL-STD-1840A, MIL-D-28000A (IGES), MIL-M-28001B (SGML), MIL-R-28002A (Raster), MIL-D-28003 (CGM). Quick Short Test Report.  

Science.gov (United States)

The primary objectives of the Air Force Continuous Acquisition and Life-cycle Support (CALS) Test Network (AFCTN) is to evaluate the effectiveness of the CALS standards for technical data interchange and to demonstrate the technical capabilities and opera...

1994-01-01

40

Technical Manual Transfer TO 31R2-2FRC181-42 Using Raytheon Company's Data Supporting ESC/MSK's MILSTAR Program: MIL-STD-1840A, MIL-D-28000A (IGES), MIL-M-28001A (SGML), MIL-D-28003 (CGM). Quick Short Test Report.  

Science.gov (United States)

The primary objective of the Air Force Continuous Acquisition and Life-cycle Support (CALS) Test Network (AFCTN) is to evaluate the effectiveness of the CALS standards for technical data interchange and to demonstrate the technical capabilities and operat...

1994-01-01

 
 
 
 
41

Pressure drop variation as a function of axial and radial power distribution in CANDU fuel channel with standard and CANFLEX 43 bundles  

International Nuclear Information System (INIS)

CANDU 600 nuclear reactors are usually fuelled with STANDARD (STD), 37 rods fuel bundles. Natural uranium (NU) dioxide (UO_2), is used as fuel composition. A new fuel bundle geometry called CANFLEX (CFX) with 43 rods is proposed and some new fuel composition are considered. Flexibility is the key word for the attempt to use some different fuel geometries and compositions for CANDU 600 nuclear reactors as well as for innovative ACR-700/1000 nuclear reactors. The fuel bundle considered in this paper is CFX-RU-0.90 that encodes the CANFLEX geometry, recycled dioxide uranium (RU) with 0.90% enrichment. The goal of this proposal is ambitious: a higher average discharge burn-up up to 14000 MWd/tU and, for the same amount of generated electric power, reduction in nuclear fuel fabrication, reduction of spent nuclear fuel radioactive waste and reduction of refueling operational work by using fewer bundles. An improved sub-channel approach for thermal-hydraulic analysis is ...

2007-11-22

42

Sandia`s network for supercomputing `95: Validating the progress of Asynchronous Transfer Mode (ATM) switching  

Energy Technology Data Exchange (ETDEWEB)

The Advanced Networking Integration Department at Sandia National Laboratories has used the annual Supercomputing conference sponsored by the IEEE and ACM for the past three years as a forum to demonstrate and focus communication and networking developments. For Supercomputing `95, Sandia elected: to demonstrate the functionality and capability of an AT&T Globeview 20Gbps Asynchronous Transfer Mode (ATM) switch, which represents the core of Sandia`s corporate network, to build and utilize a three node 622 megabit per second Paragon network, and to extend the DOD`s ACTS ATM Internet from Sandia, New Mexico to the conference`s show floor in San Diego, California, for video demonstrations. This paper documents those accomplishments, discusses the details of their implementation, and describes how these demonstrations supports Sandia`s overall strategies in ATM networking.

1996-04-01

43

Loop frame of reference based three-phase power flow for unbalanced radial distribution systems  

Energy Technology Data Exchange (ETDEWEB)

This paper introduces a novel three-phase power flow approach for unbalanced radial distribution systems. The proposed approach is developed based on the loop frame of reference, rather than the traditional bus frame of reference. On the basis of the loop frame of reference, a simple direct iterative method in impedance form is applied. Basic graph theory and injection current technique are also applied in the proposed approach. The clear theoretical foundation and the simple topology of the radial distribution network make the proposed method efficient and reliable. To demonstrate the better convergence performance and the efficiency of the proposed approach, four three-phase IEEE test feeders are used for comparisons. The test results show that the proposed method has robust convergence characteristics and high performance, especially for large-scale radial distribution systems. (author)

2010-07-15

44

A new fuzzy decision-making procedure applied to emergency electric power distribution scheduling  

Energy Technology Data Exchange (ETDEWEB)

In this paper a new fuzzy decision-making procedure is developed. Two levels of weightings, called upper and lower weights, are proposed to calculate the fuzzy weightings of different criteria. The preference table is introduced to calculate the upper and lower weights. Also a new method is developed to determine the expected preference values of different alternatives. These values are used for generating the priority list of alternatives. The procedure is applied for providing an emergency electric power distribution, scheduling time table. The IEEE 14-bus standard system and a 14-bus system with four power plants are considered as case studies. Using fuzzy decision-making procedure, the regions with more priorities are more connected to the distribution net, while the maximum consumption criterion is also reasonably respected. (author)

2000-12-01

45

A multi-objective framework for dynamic transmission expansion planning in competitive electricity market  

Energy Technology Data Exchange (ETDEWEB)

Restructuring of power system has changed the traditional planning objectives and introduced challenges in the field of Transmission Expansion Planning (TEP). Due to these changes, new approaches and criteria are needed for transmission planning in deregulated environment. Therefore, in this paper, a dynamic expansion methodology is presented using a multi-objective optimization framework. Investment cost, congestion cost and reliability are considered in the optimization as three objectives. To overcome the difficulties in solving the non-convex and mixed integer nature of the optimization problems, a Non-Dominated Sorting Genetic Algorithm (NSGA II) approach is used followed by a fuzzy decision making analysis to obtain the final optimal solution. The planning methodology has been demonstrated on the IEEE 24-bus test system and north-east of Iran national 400 kV transmission grid to show the feasibility and capabilities of the proposed algorithm in electricity ...

2010-10-15

46

Implementing 10 CFR Part 830 Subpart B at WIPP  

Energy Technology Data Exchange (ETDEWEB)

Implementation of Title 10 Code of Federal Regulations Part 830, Subpart B Nuclear Safety Management (1) was accomplished at the Waste Isolation Pilot Plant (WIPP) in a timely and efficient manner. The primary reason the transition went smoothly was that the existing safety analysis was relatively new, initially developed in 1995, and written in accordance with the safe harbor document DOE-STD-3009 (2). The WIPP Safety Analysis Report (SAR) (3) is kept up-to-date with the unreviewed safety question (USQ) process and thorough oversight and input provided by DOE-Carlsbad Field Office (CBFO) documented in the annual safety evaluation report (SER) process.

2002-02-26

47

Photovoltaic performance and reliability workshop  

Energy Technology Data Exchange (ETDEWEB)

This proceedings is the compilation of papers presented at the ninth PV Performance and Reliability Workshop held at the Sheraton Denver West Hotel on September 4--6, 1996. This years workshop included presentations from 25 speakers and had over 100 attendees. All of the presentations that were given are included in this proceedings. Topics of the papers included: defining service lifetime and developing models for PV module lifetime; examining and determining failure and degradation mechanisms in PV modules; combining IEEE/IEC/UL testing procedures; AC module performance and reliability testing; inverter reliability/qualification testing; standardization of utility interconnect requirements for PV systems; need activities to separate variables by testing individual components of PV systems (e.g. cells, modules, batteries, inverters,charge controllers) for individual reliability and then test them in actual system configurations; more results reported from field ...

1996-10-01

48

On the application of Allan variance method for Ring Laser Gyro performance characterization  

Energy Technology Data Exchange (ETDEWEB)

This report describes the method of Allan variance and its application to the characterization of a Ring Laser Gyro`s (RLG) performance. Allan variance, a time domain analysis technique, is an accepted IEEE standard for gyro specifications. The method was initially developed by David Allan of the National Bureau of Standards to quantify the error statistics of a Cesium beam frequency standard employed as the US Frequency Standards in 1960`s. The method can, in general, be applied to analyze the error characteristics of any precision measurement instrument. The key attribute of the method is that it allows for a finer, easier characterization and identification of error sources and their contribution to the overall noise statistics. This report presents an overview of the method, explains the relationship between Allan variance and power spectral density distribution of underlying noise sources, describes the batch and recursive implementation approaches, validates ...

1993-10-15

49

Normal boundary intersection method for suppliers' strategic bidding in electricity markets: An environmental/economic approach  

Energy Technology Data Exchange (ETDEWEB)

In this paper the problem of developing optimal bidding strategies for the participants of oligopolistic energy markets is studied. Special attention is given to the impacts of suppliers' emission of pollutants on their bidding strategies. The proposed methodology employs supply function equilibrium (SFE) model to represent the strategic behavior of each supplier and locational marginal pricing mechanism for the market clearing. The optimal bidding strategies are developed mathematically using a bilevel optimization problem where the upper-level subproblem maximizes individual supplier payoff and the lower-level subproblem solves the Independent System Operator's market clearing problem. In order to solve market clearing mechanism the multiobjective optimal power flow is used with supplier emission of pollutants, as an extra objective, subject to the supplier physical constraints. This paper uses normal boundary intersection (NBI) approach for generating Pareto ...

2010-06-15

50

Increasing the operational safety of nuclear facilities by using special insulation parts in the containment zone  

International Nuclear Information System (INIS)

LOCA (Loss of coolant accident) resistant heat-shrinkable polymeric products are widely used for the connection of LV cables for class 1E systems inside the containment area of nuclear power plants. The paper/presentation describes the verification of a reformulated compound for these products, where certain components of the compound formulation had to be substituted. A qualification programme with this so-called reformulated compound was undertaken to proof the equivalency of the products to the products made out of the original compound. The basic elements of this requalification project were material qualification tests including accelerated aging tests according to the arrhenius method and type tests in accordance to IEEE 383, including flammability tests. The test results showed that the products made out of the reformulated compound were similar in fit, form and function to the original products. Additional tests have also proven higher application ranges ...

2005-06-15

51

Impact of independent power producers in a deregulated system  

Energy Technology Data Exchange (ETDEWEB)

Independent power producers (IPPs) have had open access to existing power systems ever since the electric power industry was restructured and deregulated. IPPs are small-scale, distributed, and independently operated. Introducing an IPP to the power system can be beneficial to the existing power system because it can increase the security margin or reduce production cost and environmental pollution. The disadvantage is that some IPPs are not subject to dispatch control, consequently, they may reduce the network security. Often IPPs use co-generation, small-scale hydro, even fuel cells or other types of renewable energy sources. An evaluation of IPPs impact on an existing utility power system was determined in a modified IEEE 14 bus system. The total generating cost, environmental impact, transmission line margin, voltage profile, network congestion, security and other power quality measures were evaluated. It was concluded that on balance, an IPP improves the ...

1997-04-01

52

Electric power system design: The NEC and the IEC approach  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to compare the techniques and results obtained when a general industrial or commercial building power electrical system is prepared using the US National Electrical Code{copyright} (NEC) and the International Electrotechnical Commission (IEC) Standards. The final design offer the reader the possibility of making an initial comparison and analyzation of the two methods based of their overall effectiveness (sizing, protection, co-ordination of protective devices with components etc.), safety and cost. In order to make such a comparison a specific example was developed and limited in detail to avoid complexity in this study. The power source selected will be a delta-wye utility supplied transformer feeding various load groups such as lighting and motor circuits (possibly through associated transformers). Relevant NE Code references, IEC standards, and appropriate justifications will be made at various points. Since this paper is for comparison purpose only, ...

1995-12-31

53

Distributed MAC Protocol Supporting Physical-Layer Network Coding  

CERN Document Server

Physical-layer network coding (PNC) is a promising approach for wireless networks. It allows nodes to transmit simultaneously. Due to the difficulties of scheduling simultaneous transmissions, existing works on PNC are based on simplified medium access control (MAC) protocols, which are not applicable to general multi-hop wireless networks, to the best of our knowledge. In this paper, we propose a distributed MAC protocol that supports PNC in multi-hop wireless networks. The proposed MAC protocol is based on the carrier sense multiple access (CSMA) strategy and can be regarded as an extension to the IEEE 802.11 MAC protocol. In the proposed protocol, each node collects information on the queue status of its neighboring nodes. When a node finds that there is an opportunity for some of its neighbors to perform PNC, it notifies its corresponding neighboring nodes and initiates the process of packet exchange using PNC, with the node itself as a relay. During the packet ...

2011-01-01

54

Damping inter-area modes of oscillation using an adaptive fuzzy power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

This paper introduces an indirect adaptive fuzzy controller as a power system stabilizer used to damp inter-area modes of oscillation following disturbances in power systems. Compared to the IEEE standard multi-band power system stabilizer (MB-PSS), indirect adaptive fuzzy-based stabilizers are more efficient because they can cope with oscillations at different operating points. A nominal model of the power system is identified on-line using a variable structure identifier. A feedback linearization-based control law is implemented using the identified model. The gains of the controller are tuned via a particle swarm optimization routine to ensure system stability and minimum sum of the squares of the speed deviations. A bench-mark problem of a 4-machine 2-area power system is used to demonstrate the performance of the proposed controller and to show its superiority over other conventional stabilizers used in the literature. (author)

2010-12-15

55

Automatic system for measuring dose-area product (DAP) in ROI fluoroscopy  

Energy Technology Data Exchange (ETDEWEB)

A computerized system for monitoring dose-area product (DAP) has been developed for region of interest (ROI) fluoroscopy in which patient exposure is reduced using an x-ray attenuating filter with an aperture. The system includes an IBM compatible computer which is connected through an IEEE-488 interface to an electrometer which measures the charge from a DAP ionization chamber. A digital input/output board connects the computer to the filter placement device to determine whether the filter is in or out of the beam, and to the x-ray generator to determine when the exposure is due to spot filming. The computer logs the DAP from conventional fluoroscopy, ROI fluoroscopy and spot filming separately, applying the appropriate calibration factor for each. Measured DAPs, fluoroscopic DAP rates and exposure times are displayed in real-time. The system has been installed in a GI fluoroscopic room so that the dose-reduction potential of ROI imaging can be evaluated. (author)

1997-04-01

56

Renewable natural fats and their derivatives as source of fuels. 1. Physical properties of vegetable oil and farm engines diesel fuel mixtures  

Energy Technology Data Exchange (ETDEWEB)

The characteristics of diesel fuel jet atomization in carburetors depend on dynamic viscosity (v) density (d) and surface tension (st) of fuel, grouped in the combined functions v/d; st/v and st/d. Values of these combined functions for binary mixtures of a farm diesel fuel with a crude vegetable oil (sunflower, soybean, cotton and foot-cake olive oils) as well as with a used frying olive oil, are calculated. Three different diesel fuels have been studied. Combined function values of these mixtures are influenced by the characteristics of their diesel fuel. Mixtures containing less than 24% of any studied crude oils show kinematic viscosity values at 40 degrees C not exceeding 5.8 squared millimeters/s. This value is the higher limit for typical United States farm diesel fuels, according to specifications of the Cummins Engine Company. Mixture with 21% of the used frying olive oil shows at 40 degrees C this kinematic viscosity.

1985-09-01

57

Effect of helium and hydrogen production on irradiation hardening of F82H steel irradiated by ion beams  

International Nuclear Information System (INIS)

Effects of helium and hydrogen production on irradiation hardening of martensitic steel F82H (Fe-8Cr-2W-0.2V-0.04Ta-0.1C) were examined by dual or triple beam experiments. The effects of tempering and cold working were also examined. The irradiations were performed at about 500degC to 50 dpa under simultaneous dual beams of 10.5 MeV Fe"3"+ and 1.05 MeV He"+ or triple beams of those and 380 keV H"+ ions. The value of appm-He/dpa for the dual ion beams was about 15, and the values of appm-He/dpa and appm-H/dpa for the triple ion beams were 15 and 15 (or 150), respectively. The hardness of the irradiated specimens measured at room temperature using a micro indentation after the irradiations. Irradiation softening and hardening was observed in F82H-std, F82H+20%CW and a non-tempered F82H steels irradiated at about 500degC to 18 and 50 dpa, respectively, by dual ion beams. The hardness of the specimens irradiated at about 500degC to 18 dpa under triple ion beams was ...

2007-06-01

58

Effect of helium and hydrogen production on hardness of F82H steel irradiated by dual/triple ion beams  

International Nuclear Information System (INIS)

Effect of helium and hydrogen production on radiation-hardening of F82H irradiated by dual or triple beam condition were investigated. The specimens used were four types of ferritic martensitic steels of F82H-std (Fe-8Cr-2W-0.2V-0.04Ta-0.1C) steels tempered at 750degC for 60 minutes, 20% cold worked F82H steel, F82H tempered for 10 minutes and non-tempered F82H steels. The irradiation was performed at 450degC to 50 dpa under simultaneous dual beams of 10.5 MeV Fe"3"+ and 1.05 MeV He"+ or triple beams of those and 380 keV H"+ ions. The ratios of He (appm)/dpa and H(appm)/dpa were 15 nad 15 (or 150) for dual and triple ion beams. The hardness of the irradiated specimens measured at room temperature using a micro indentation after the irradiations. The hardness in these F82H steels irradiated at 450degC to 18 dpa under triple beam irradiation was harder than that under dual beam irradiation. Irradiation softening and hardening under dual beams was observed in F82H ...

2003-03-01

59

MANAGEMENT PRE-START REVIEW FINAL REPORT FOR THE BIOSAFETY LEVEL 3 (BSL-3) FACILITY (B368) LAWRENCE LIVERMORE NATIONAL LABORATORY  

Energy Technology Data Exchange (ETDEWEB)

A Lawrence Livermore National Laboratory (LLNL) Management Pre-Start Review (MPR) Team was formed to independently verify the operational readiness of Building 368 (B368) Biosafety Level III (BSL-3) Facility to conduct research with biological pathogens and toxins including those considered Select Agents. Review objectives and criteria were developed from the DOE/NNSA and LLNL requirements. These were provided in the Implementation Plan for the Biosafety Level III (BSL-3) Facility Management Pre-Start Review (BSL-3 MPR) at Lawrence Livermore National Laboratory that was reviewed and approved by DOE/NNSA-LSO. The formal part of the LLNL MPR for the BSL-3 Facility was begun in August of 2005 but work on the MPR was stopped in October of 2005 due to the need for LLNL to reassess organizational and operational controls and respond to Centers for Disease Control and Prevention inquiries related to a shipping incident involving select agents. The MPR was restarted in mid-June of 2006. ...

2006-07-25

60

National Ignition Facility Incorporates P2/E2 in Aqueous Parts Cleaning of Optics Hardware  

Energy Technology Data Exchange (ETDEWEB)

When completed, Lawrence Livermore National Laboratory's (LLNL) National Ignition Facility (NIF) will be the world's largest laser with experimental capabilities applicable to stockpile stewardship, energy research, science and astrophysics. As construction of the conventional facilities nears completion, operations supporting the installation of specialized laser equipment have come online. Playing a critical role in the precision cleaning of mechanical parts from the NIF beamline are three pieces of aqueous cleaning equipment. Housed in the Optics Assembly Building (OAB), adjacent to NIF's laser bay, are the large mechanical parts gross cleaner (LMPGC), the large mechanical parts precision cleaner (LMPPC), and the small mechanical parts gross and precision cleaner (SMPGPC). These aqueous units, designed and built by Sonic Systems, Inc., of Newtown, Pennsylvania, not only accommodate parts that vary greatly in size, weight, geometry, surface finish and ...

2001-07-27